Sample records for techniques standards activities

  1. NASA standard: Trend analysis techniques

    NASA Technical Reports Server (NTRS)

    1988-01-01

    This Standard presents descriptive and analytical techniques for NASA trend analysis applications. Trend analysis is applicable in all organizational elements of NASA connected with, or supporting, developmental/operational programs. Use of this Standard is not mandatory; however, it should be consulted for any data analysis activity requiring the identification or interpretation of trends. Trend Analysis is neither a precise term nor a circumscribed methodology, but rather connotes, generally, quantitative analysis of time-series data. For NASA activities, the appropriate and applicable techniques include descriptive and graphical statistics, and the fitting or modeling of data by linear, quadratic, and exponential models. Usually, but not always, the data is time-series in nature. Concepts such as autocorrelation and techniques such as Box-Jenkins time-series analysis would only rarely apply and are not included in this Standard. The document presents the basic ideas needed for qualitative and quantitative assessment of trends, together with relevant examples. A list of references provides additional sources of information.

  2. Optimal Use of TDOA Geo-Location Techniques Within the Mountainous Terrain of Turkey

    DTIC Science & Technology

    2012-09-01

    Cross -Correlation TDOA Estimation Technique ................. 49 3. Standard Deviation...76 Figure 32. The Effect of Noise on Accuracy ........................................................ 77 Figure 33. The Effect of Noise to...finding techniques. In contrast, people have been using active location finding techniques, such as radar , for decades. When active location finding

  3. Activities report of PTT Research

    NASA Astrophysics Data System (ADS)

    In the field of postal infrastructure research, activities were performed on postcode readers, radiolabels, and techniques of operations research and artificial intelligence. In the field of telecommunication, transportation, and information, research was made on multipurpose coding schemes, speech recognition, hypertext, a multimedia information server, security of electronic data interchange, document retrieval, improvement of the quality of user interfaces, domotics living support (techniques), and standardization of telecommunication prototcols. In the field of telecommunication infrastructure and provisions research, activities were performed on universal personal telecommunications, advanced broadband network technologies, coherent techniques, measurement of audio quality, near field facilities, local beam communication, local area networks, network security, coupling of broadband and narrowband integrated services digital networks, digital mapping, and standardization of protocols.

  4. Muscle activity characterization by laser Doppler Myography

    NASA Astrophysics Data System (ADS)

    Scalise, Lorenzo; Casaccia, Sara; Marchionni, Paolo; Ercoli, Ilaria; Primo Tomasini, Enrico

    2013-09-01

    Electromiography (EMG) is the gold-standard technique used for the evaluation of muscle activity. This technique is used in biomechanics, sport medicine, neurology and rehabilitation therapy and it provides the electrical activity produced by skeletal muscles. Among the parameters measured with EMG, two very important quantities are: signal amplitude and duration of muscle contraction, muscle fatigue and maximum muscle power. Recently, a new measurement procedure, named Laser Doppler Myography (LDMi), for the non contact assessment of muscle activity has been proposed to measure the vibro-mechanical behaviour of the muscle. The aim of this study is to present the LDMi technique and to evaluate its capacity to measure some characteristic features proper of the muscle. In this paper LDMi is compared with standard superficial EMG (sEMG) requiring the application of sensors on the skin of each patient. sEMG and LDMi signals have been simultaneously acquired and processed to test correlations. Three parameters has been analyzed to compare these techniques: Muscle activation timing, signal amplitude and muscle fatigue. LDMi appears to be a reliable and promising measurement technique allowing the measurements without contact with the patient skin.

  5. Neutron activation analysis of certified samples by the absolute method

    NASA Astrophysics Data System (ADS)

    Kadem, F.; Belouadah, N.; Idiri, Z.

    2015-07-01

    The nuclear reactions analysis technique is mainly based on the relative method or the use of activation cross sections. In order to validate nuclear data for the calculated cross section evaluated from systematic studies, we used the neutron activation analysis technique (NAA) to determine the various constituent concentrations of certified samples for animal blood, milk and hay. In this analysis, the absolute method is used. The neutron activation technique involves irradiating the sample and subsequently performing a measurement of the activity of the sample. The fundamental equation of the activation connects several physical parameters including the cross section that is essential for the quantitative determination of the different elements composing the sample without resorting to the use of standard sample. Called the absolute method, it allows a measurement as accurate as the relative method. The results obtained by the absolute method showed that the values are as precise as the relative method requiring the use of standard sample for each element to be quantified.

  6. Calibrating and training of neutron based NSA techniques with less SNM standards

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Geist, William H; Swinhoe, Martyn T; Bracken, David S

    2010-01-01

    Accessing special nuclear material (SNM) standards for the calibration of and training on nondestructive assay (NDA) instruments has become increasingly difficult in light of enhanced safeguards and security regulations. Limited or nonexistent access to SNM has affected neutron based NDA techniques more than gamma ray techniques because the effects of multiplication require a range of masses to accurately measure the detector response. Neutron based NDA techniques can also be greatly affected by the matrix and impurity characteristics of the item. The safeguards community has been developing techniques for calibrating instrumentation and training personnel with dwindling numbers of SNM standards. Montemore » Carlo methods have become increasingly important for design and calibration of instrumentation. Monte Carlo techniques have the ability to accurately predict the detector response for passive techniques. The Monte Carlo results are usually benchmarked to neutron source measurements such as californium. For active techniques, the modeling becomes more difficult because of the interaction of the interrogation source with the detector and nuclear material; and the results cannot be simply benchmarked with neutron sources. A Monte Carlo calculated calibration curve for a training course in Indonesia of material test reactor (MTR) fuel elements assayed with an active well coincidence counter (AWCC) will be presented as an example. Performing training activities with reduced amounts of nuclear material makes it difficult to demonstrate how the multiplication and matrix properties of the item affects the detector response and limits the knowledge that can be obtained with hands-on training. A neutron pulse simulator (NPS) has been developed that can produce a pulse stream representative of a real pulse stream output from a detector measuring SNM. The NPS has been used by the International Atomic Energy Agency (IAEA) for detector testing and training applications at the Agency due to the lack of appropriate SNM standards. This paper will address the effect of reduced access to SNM for calibration and training of neutron NDA applications along with the advantages and disadvantages of some solutions that do not use standards, such as the Monte Carlo techniques and the NPS.« less

  7. Advanced analysis techniques for uranium assay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Geist, W. H.; Ensslin, Norbert; Carrillo, L. A.

    2001-01-01

    Uranium has a negligible passive neutron emission rate making its assay practicable only with an active interrogation method. The active interrogation uses external neutron sources to induce fission events in the uranium in order to determine the mass. This technique requires careful calibration with standards that are representative of the items to be assayed. The samples to be measured are not always well represented by the available standards which often leads to large biases. A technique of active multiplicity counting is being developed to reduce some of these assay difficulties. Active multiplicity counting uses the measured doubles and triples countmore » rates to determine the neutron multiplication (f4) and the product of the source-sample coupling ( C ) and the 235U mass (m). Since the 35U mass always appears in the multiplicity equations as the product of Cm, the coupling needs to be determined before the mass can be known. A relationship has been developed that relates the coupling to the neutron multiplication. The relationship is based on both an analytical derivation and also on empirical observations. To determine a scaling constant present in this relationship, known standards must be used. Evaluation of experimental data revealed an improvement over the traditional calibration curve analysis method of fitting the doubles count rate to the 235Um ass. Active multiplicity assay appears to relax the requirement that the calibration standards and unknown items have the same chemical form and geometry.« less

  8. NASA standard: Trend analysis techniques

    NASA Technical Reports Server (NTRS)

    1990-01-01

    Descriptive and analytical techniques for NASA trend analysis applications are presented in this standard. Trend analysis is applicable in all organizational elements of NASA connected with, or supporting, developmental/operational programs. This document should be consulted for any data analysis activity requiring the identification or interpretation of trends. Trend analysis is neither a precise term nor a circumscribed methodology: it generally connotes quantitative analysis of time-series data. For NASA activities, the appropriate and applicable techniques include descriptive and graphical statistics, and the fitting or modeling of data by linear, quadratic, and exponential models. Usually, but not always, the data is time-series in nature. Concepts such as autocorrelation and techniques such as Box-Jenkins time-series analysis would only rarely apply and are not included in this document. The basic ideas needed for qualitative and quantitative assessment of trends along with relevant examples are presented.

  9. A no-gold-standard technique for objective assessment of quantitative nuclear-medicine imaging methods

    PubMed Central

    Jha, Abhinav K; Caffo, Brian; Frey, Eric C

    2016-01-01

    The objective optimization and evaluation of nuclear-medicine quantitative imaging methods using patient data is highly desirable but often hindered by the lack of a gold standard. Previously, a regression-without-truth (RWT) approach has been proposed for evaluating quantitative imaging methods in the absence of a gold standard, but this approach implicitly assumes that bounds on the distribution of true values are known. Several quantitative imaging methods in nuclear-medicine imaging measure parameters where these bounds are not known, such as the activity concentration in an organ or the volume of a tumor. We extended upon the RWT approach to develop a no-gold-standard (NGS) technique for objectively evaluating such quantitative nuclear-medicine imaging methods with patient data in the absence of any ground truth. Using the parameters estimated with the NGS technique, a figure of merit, the noise-to-slope ratio (NSR), can be computed, which can rank the methods on the basis of precision. An issue with NGS evaluation techniques is the requirement of a large number of patient studies. To reduce this requirement, the proposed method explored the use of multiple quantitative measurements from the same patient, such as the activity concentration values from different organs in the same patient. The proposed technique was evaluated using rigorous numerical experiments and using data from realistic simulation studies. The numerical experiments demonstrated that the NSR was estimated accurately using the proposed NGS technique when the bounds on the distribution of true values were not precisely known, thus serving as a very reliable metric for ranking the methods on the basis of precision. In the realistic simulation study, the NGS technique was used to rank reconstruction methods for quantitative single-photon emission computed tomography (SPECT) based on their performance on the task of estimating the mean activity concentration within a known volume of interest. Results showed that the proposed technique provided accurate ranking of the reconstruction methods for 97.5% of the 50 noise realizations. Further, the technique was robust to the choice of evaluated reconstruction methods. The simulation study pointed to possible violations of the assumptions made in the NGS technique under clinical scenarios. However, numerical experiments indicated that the NGS technique was robust in ranking methods even when there was some degree of such violation. PMID:26982626

  10. A no-gold-standard technique for objective assessment of quantitative nuclear-medicine imaging methods.

    PubMed

    Jha, Abhinav K; Caffo, Brian; Frey, Eric C

    2016-04-07

    The objective optimization and evaluation of nuclear-medicine quantitative imaging methods using patient data is highly desirable but often hindered by the lack of a gold standard. Previously, a regression-without-truth (RWT) approach has been proposed for evaluating quantitative imaging methods in the absence of a gold standard, but this approach implicitly assumes that bounds on the distribution of true values are known. Several quantitative imaging methods in nuclear-medicine imaging measure parameters where these bounds are not known, such as the activity concentration in an organ or the volume of a tumor. We extended upon the RWT approach to develop a no-gold-standard (NGS) technique for objectively evaluating such quantitative nuclear-medicine imaging methods with patient data in the absence of any ground truth. Using the parameters estimated with the NGS technique, a figure of merit, the noise-to-slope ratio (NSR), can be computed, which can rank the methods on the basis of precision. An issue with NGS evaluation techniques is the requirement of a large number of patient studies. To reduce this requirement, the proposed method explored the use of multiple quantitative measurements from the same patient, such as the activity concentration values from different organs in the same patient. The proposed technique was evaluated using rigorous numerical experiments and using data from realistic simulation studies. The numerical experiments demonstrated that the NSR was estimated accurately using the proposed NGS technique when the bounds on the distribution of true values were not precisely known, thus serving as a very reliable metric for ranking the methods on the basis of precision. In the realistic simulation study, the NGS technique was used to rank reconstruction methods for quantitative single-photon emission computed tomography (SPECT) based on their performance on the task of estimating the mean activity concentration within a known volume of interest. Results showed that the proposed technique provided accurate ranking of the reconstruction methods for 97.5% of the 50 noise realizations. Further, the technique was robust to the choice of evaluated reconstruction methods. The simulation study pointed to possible violations of the assumptions made in the NGS technique under clinical scenarios. However, numerical experiments indicated that the NGS technique was robust in ranking methods even when there was some degree of such violation.

  11. A Corona Discharge Initiated Electrochemical Electrospray Ionization Technique

    PubMed Central

    Lloyd, John R.; Hess, Sonja

    2009-01-01

    We report here the development of a corona discharge (CD) initiated electrochemical (EC) electrospray ionization (ESI) technique using a standard electrospray ion source. This is a new ionization technique distinct from ESI, electrochemistry inherent to ESI, APCI, and techniques using hydroxyl radicals produced under atmospheric pressure conditions. By maximizing the observable CD at the tip of a stainless steel ESI capillary, efficient electrochemical oxidation of electrochemically active compounds is observed. For electrochemical oxidation to be observed, the ionization potential of the analyte must be lower than Fe. Ferrocene labeled compounds were chosen as the electrochemically active moiety. The electrochemical cell in the ESI source was robust and generated ions with selectivity according to the ionization potential of the analytes and up to zeptomolar sensitivity. Our results indicate that CD initiated electrochemical ionization has the potential to become a powerful technique to increase the dynamic range, sensitivity and selectivity of ESI experiments. Synopsis Using a standard ESI source a corona discharge initiated electrochemical ionization technique was established resulting from the electrochemistry occurring at the CD electrode surface. PMID:19747843

  12. A Review of NIST Primary Activity Standards for (18)F: 1982 to 2013.

    PubMed

    Bergeron, Denis E; Cessna, Jeffrey T; Coursey, Bert M; Fitzgerald, Ryan; Zimmerman, Brian E

    2014-01-01

    The new NIST activity standardization for (18)F, described in 2014 in Applied Radiation and Isotopes (v. 85, p. 77), differs from results obtained between 1998 and 2008 by 4 %. The new results are considered to be very reliable; they are based on a battery of robust primary measurement techniques and bring the NIST standard into accord with other national metrology institutes. This paper reviews all ten (18)F activity standardizations performed at NIST from 1982 to 2013, with a focus on experimental variables that might account for discrepancies. We have identified many possible sources of measurement bias and eliminated most of them, but we have not adequately accounted for the 1998-2008 results.

  13. Ar+ and CuBr laser-assisted chemical bleaching of teeth: estimation of whiteness degree

    NASA Astrophysics Data System (ADS)

    Dimitrov, S.; Todorovska, Roumyana; Gizbrecht, Alexander I.; Raychev, L.; Petrov, Lyubomir P.

    2003-11-01

    In this work the results of adaptation of impartial methods for color determination aimed at developing of techniques for estimation of human teeth whiteness degree, sufficiently handy for common use in clinical practice are presented. For approbation and by the way of illustration of the techniques, standards of teeth colors were used as well as model and naturally discolored human teeth treated by two bleaching chemical compositions activated by three light sources each: Ar+ and CuBr lasers, and a standard halogen photopolymerization lamp. Typical reflection and fluorescence spectra of some samples are presented; the samples colors were estimated by a standard computer processing in RGB and B coordinates. The results of the applied spectral and colorimetric techniques are in a good agreement with those of the standard computer processing of the corresponding digital photographs and complies with the visually estimated degree of the teeth whiteness judged according to the standard reference scale commonly used in the aesthetic dentistry.

  14. A Review of NIST Primary Activity Standards for 18F: 1982 to 2013

    PubMed Central

    Bergeron, Denis E; Cessna, Jeffrey T; Coursey, Bert M; Fitzgerald, Ryan; Zimmerman, Brian E

    2014-01-01

    The new NIST activity standardization for 18F, described in 2014 in Applied Radiation and Isotopes (v. 85, p. 77), differs from results obtained between 1998 and 2008 by 4 %. The new results are considered to be very reliable; they are based on a battery of robust primary measurement techniques and bring the NIST standard into accord with other national metrology institutes. This paper reviews all ten 18F activity standardizations performed at NIST from 1982 to 2013, with a focus on experimental variables that might account for discrepancies. We have identified many possible sources of measurement bias and eliminated most of them, but we have not adequately accounted for the 1998–2008 results. PMID:26601035

  15. Objective evaluation of reconstruction methods for quantitative SPECT imaging in the absence of ground truth.

    PubMed

    Jha, Abhinav K; Song, Na; Caffo, Brian; Frey, Eric C

    2015-04-13

    Quantitative single-photon emission computed tomography (SPECT) imaging is emerging as an important tool in clinical studies and biomedical research. There is thus a need for optimization and evaluation of systems and algorithms that are being developed for quantitative SPECT imaging. An appropriate objective method to evaluate these systems is by comparing their performance in the end task that is required in quantitative SPECT imaging, such as estimating the mean activity concentration in a volume of interest (VOI) in a patient image. This objective evaluation can be performed if the true value of the estimated parameter is known, i.e. we have a gold standard. However, very rarely is this gold standard known in human studies. Thus, no-gold-standard techniques to optimize and evaluate systems and algorithms in the absence of gold standard are required. In this work, we developed a no-gold-standard technique to objectively evaluate reconstruction methods used in quantitative SPECT when the parameter to be estimated is the mean activity concentration in a VOI. We studied the performance of the technique with realistic simulated image data generated from an object database consisting of five phantom anatomies with all possible combinations of five sets of organ uptakes, where each anatomy consisted of eight different organ VOIs. Results indicate that the method provided accurate ranking of the reconstruction methods. We also demonstrated the application of consistency checks to test the no-gold-standard output.

  16. Interference by the activated sludge matrix on the analysis of soluble microbial products in wastewater.

    PubMed

    Potvin, Christopher M; Zhou, Hongde

    2011-11-01

    The objective of this study was to demonstrate the effects of complex matrix effects caused by chemical materials on the analysis of key soluble microbial products (SMP) including proteins, humics, carbohydrates, and polysaccharides in activated sludge samples. Emphasis was placed on comparison of the commonly used standard curve technique with standard addition (SA), a technique that differs in that the analytical responses are measured for sample solutions spiked with known quantities of analytes. The results showed that using SA provided a great improvement in compensating for SMP recovery and thus improving measurement accuracy by correcting for matrix effects. Analyte recovery was found to be highly dependent on sample dilution, and changed due to extraction techniques, storage conditions and sample composition. Storage of sample extracts by freezing changed SMP concentrations dramatically, as did storage at 4°C for as little as 1d. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. Progress in revising and supplementing fundamental optical ISO standards

    NASA Astrophysics Data System (ADS)

    Schuhmann, Rainer

    2017-11-01

    This overview reflects the ISO working group activities of ISO/TC 172 Subcommittee 1 during the last years which have resulted in revisions and new ISO standards for optical components. For ISO 10110, ISO 14999 and other standards new surface forms and metrology techniques have been considered, standards about material characteristics have been consolidated, and optical drawings have been updated. Selected examples of new improvements and future work items are given.

  18. Brief review: Preparation techniques of biomass based activated carbon monolith electrode for supercapacitor applications

    NASA Astrophysics Data System (ADS)

    Taer, Erman; Taslim, Rika

    2018-02-01

    The synthesis of activated carbon monolith electrode made from a biomass material using the hydrolytic pressure or the pelletization technique of pre-carbonized materials is one of standard reported methods. Several steps such as pre-carbonization, milling, chemical activation, hydraulic press, carbonization, physical activation, polishing and washing need to be accomplished in the production of electrodes by this method. This is relatively a long process that need to be simplified. In this paper we present the standard method and proceed with the introduction to several alternative methods in the synthesis of activated carbon monolith electrodes. The alternative methods were emphasized on the selection of suitable biomass materials. All of carbon electrodes prepared by different methods will be analyzed for physical and electrochemical properties. The density, degree of crystallinity, surface morphology are examples for physical study and specific capacitance was an electrochemical properties that has been analysed. This alternative method has offered a specific capacitance in the range of 10 to 171 F/g.

  19. Pupils' Cognitive Activity Stimulation by Means of Physical Training

    ERIC Educational Resources Information Center

    Nekhoroshkov, Anatolij V.

    2016-01-01

    The article presents the research results of the physical activity influence on the intellectual performance of high school students. The methods of experiments and standardized observation were used. The efficiency of the cognitive activity was assessed by "Proof test" technique of B. Burdon. Within the experimental class, the program…

  20. Use of Tc-99m-galactosyl-neoglycoalbumin (Tc-NGA) to determine hepatic blood flow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stadalnik, R.C.; Vera, D.R.; Woodle, E.S.

    1984-01-01

    Tc-NGA is a new liver radiopharmaceutical which binds to a hepatocyte-specific membrane receptor. Three characteristics of Tc-NGA can be exploited in the measurement of hepatic blood flow (HBF): 1) ability to alter the affinity of Tc-NGA for its receptor by changing the galactose: albumin ratio; 2) ability to achieve a high specific activity with Tc-99m labeling; and 3) ability to administer a high molar dose of Tc-NGA without physiologic side effects. In addition, kinetic modeling of Tc-NGA dynamic data can provide estimates of hepatic receptor concentration. In experimental studies in young pigs, HBF was determined using two techniques: 1) kineticmore » modeling of dynamic data using moderate affinity, low specific activity Tc-NGA (Group A, n=12); and 2) clearance (CL) technique using high affinity, high specific activity Tc-NGA (Group B, n=4). In both groups, HBF was determined simultaneously by continuous infusion of indocyanine green (CI-ICG) with hepatic vein sampling. Regression analysis of HBF measurements obtained with the Tc-NGA kinetic modeling technique and the CI-ICG technique (Group A) revealed good correlation between the two techniques (r=0.802, p=0.02). Similarly, HBF determination by the clearance technique (Group B) provided highly accurate measurements when compared to the CI-ICG technique. Hepatic blood flow measurements by the clearance technique (CL-NGA) fell within one standard deviation of the error associated with each CI-ICG HBF measurement (all CI-ICG standard deviations were less than 10%).« less

  1. Eight Stars of Gold--The Story of Alaska's Flag. Primary Grade Activities.

    ERIC Educational Resources Information Center

    Alaska State Museum, Juneau.

    This activities booklet focuses on the story of Alaska's flag. The booklet is intended for teachers to use with primary-grade children. Each activity in the booklet contains background information, a summary and time estimate, Alaska state standards, a step-by-step technique for implementing the activity, assessment tips, materials and resource…

  2. Eight Stars of Gold--The Story of Alaska's Flag. Intermediate Activities (Grades 3-5).

    ERIC Educational Resources Information Center

    Alaska State Museum, Juneau.

    This activities booklet focuses on the story of Alaska's flag. The booklet is intended for teachers to use with students in the intermediate grades. Each activity in the booklet contains: background information, a summary and time estimate, state standards, a step-by-step technique for implementation of the activity, assessment tips, materials and…

  3. Eight Stars of Gold--The Story of Alaska's Flag. Middle School Activities (Grades 6-8).

    ERIC Educational Resources Information Center

    Alaska State Museum, Juneau.

    This activities booklet focuses on the story of Alaska's state flag. The booklet is for use in teaching middle school students. Each activity contains: background information, a summary and time estimate, Alaska state standards, a step-by-step technique for classroom implementation of the activity, assessment tips, materials and resources needed,…

  4. Eight Stars of Gold--The Story of Alaska's Flag. High School Activities (Grades 9-12).

    ERIC Educational Resources Information Center

    Alaska State Museum, Juneau.

    This activities booklet focuses on the story of Alaska's flag. The booklet is intended for use in teaching high school students. Each activity contains: background information; a summary and time estimate, Alaska state standards, a step-by-step technique for classroom implementation of the activity, assessment tips, materials and resources needed,…

  5. 3D thermography imaging standardization technique for inflammation diagnosis

    NASA Astrophysics Data System (ADS)

    Ju, Xiangyang; Nebel, Jean-Christophe; Siebert, J. Paul

    2005-01-01

    We develop a 3D thermography imaging standardization technique to allow quantitative data analysis. Medical Digital Infrared Thermal Imaging is very sensitive and reliable mean of graphically mapping and display skin surface temperature. It allows doctors to visualise in colour and quantify temperature changes in skin surface. The spectrum of colours indicates both hot and cold responses which may co-exist if the pain associate with an inflammatory focus excites an increase in sympathetic activity. However, due to thermograph provides only qualitative diagnosis information, it has not gained acceptance in the medical and veterinary communities as a necessary or effective tool in inflammation and tumor detection. Here, our technique is based on the combination of visual 3D imaging technique and thermal imaging technique, which maps the 2D thermography images on to 3D anatomical model. Then we rectify the 3D thermogram into a view independent thermogram and conform it a standard shape template. The combination of these imaging facilities allows the generation of combined 3D and thermal data from which thermal signatures can be quantified.

  6. A New Active Cavitation Mapping Technique for Pulsed HIFU Applications – Bubble Doppler

    PubMed Central

    Li, Tong; Khokhlova, Tatiana; Sapozhnikov, Oleg; Hwang, Joo Ha; Sapozhnikov, Oleg; O’Donnell, Matthew

    2015-01-01

    In this work, a new active cavitation mapping technique for pulsed high-intensity focused ultrasound (pHIFU) applications termed bubble Doppler is proposed and its feasibility tested in tissue-mimicking gel phantoms. pHIFU therapy uses short pulses, delivered at low pulse repetition frequency, to cause transient bubble activity that has been shown to enhance drug and gene delivery to tissues. The current gold standard for detecting and monitoring cavitation activity during pHIFU treatments is passive cavitation detection (PCD), which provides minimal information on the spatial distribution of the bubbles. B-mode imaging can detect hyperecho formation, but has very limited sensitivity, especially to small, transient microbubbles. The bubble Doppler method proposed here is based on a fusion of the adaptations of three Doppler techniques that had been previously developed for imaging of ultrasound contrast agents – color Doppler, pulse inversion Doppler, and decorrelation Doppler. Doppler ensemble pulses were interleaved with therapeutic pHIFU pulses using three different pulse sequences and standard Doppler processing was applied to the received echoes. The information yielded by each of the techniques on the distribution and characteristics of pHIFU-induced cavitation bubbles was evaluated separately, and found to be complementary. The unified approach - bubble Doppler – was then proposed to both spatially map the presence of transient bubbles and to estimate their sizes and the degree of nonlinearity. PMID:25265178

  7. Refinements in pectus carinatum correction: the pectoralis muscle split technique.

    PubMed

    Schwabegger, Anton H; Jeschke, Johannes; Schuetz, Tanja; Del Frari, Barbara

    2008-04-01

    The standard approach for correction of pectus carinatum deformity includes elevation of the pectoralis major and rectus abdominis muscle from the sternum and adjacent ribs. A postoperative restriction of shoulder activity for several weeks is necessary to allow stable healing of the elevated muscles. To reduce postoperative immobilization, we present a modified approach to the parasternal ribs using a pectoralis muscle split technique. At each level of rib cartilage resection, the pectoralis muscle is split along the direction of its fibers instead of elevating the entire muscle as performed with the standard technique. From July 2000 to May 2007, we successfully used this technique in 33 patients with pectus carinatum deformity. After the muscle split approach, patients returned to full unrestricted shoulder activity as early as 3 weeks postoperatively, compared to 6 weeks in patients treated with muscle flap elevation. Postoperative pain was reduced and the patients were discharged earlier from the hospital than following the conventional approach. The muscle split technique is a modified surgical approach to the parasternal ribs in patients with pectus carinatum deformity. It helps to maintain pectoralis muscle vascularization and function and can reduce postoperative pain, hospitalization, and rehabilitation period.

  8. 76 FR 16728 - Announcement of the American Petroleum Institute's Standards Activities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-25

    ... voluntary standards for equipment, materials, operations, and processes for the petroleum and natural gas... Techniques for Designing and/or Optimizing Gas-lift Wells and Systems, 1st Ed. RP 13K, Chemical Analysis of... Q2, Quality Management Systems for Service Supply Organizations for the Petroleum and Natural Gas...

  9. Application of Behavior Change Techniques in a Personalized Nutrition Electronic Health Intervention Study: Protocol for the Web-Based Food4Me Randomized Controlled Trial

    PubMed Central

    Macready, Anna L; Fallaize, Rosalind; Butler, Laurie T; Ellis, Judi A; Kuznesof, Sharron; Frewer, Lynn J; Celis-Morales, Carlos; Livingstone, Katherine M; Araújo-Soares, Vera; Fischer, Arnout RH; Stewart-Knox, Barbara J; Mathers, John C

    2018-01-01

    Background To determine the efficacy of behavior change techniques applied in dietary and physical activity intervention studies, it is first necessary to record and describe techniques that have been used during such interventions. Published frameworks used in dietary and smoking cessation interventions undergo continuous development, and most are not adapted for Web-based delivery. The Food4Me study (N=1607) provided the opportunity to use existing frameworks to describe standardized Web-based techniques employed in a large-scale, internet-based intervention to change dietary behavior and physical activity. Objective The aims of this study were (1) to describe techniques embedded in the Food4Me study design and explain the selection rationale and (2) to demonstrate the use of behavior change technique taxonomies, develop standard operating procedures for training, and identify strengths and limitations of the Food4Me framework that will inform its use in future studies. Methods The 6-month randomized controlled trial took place simultaneously in seven European countries, with participants receiving one of four levels of personalized advice (generalized, intake-based, intake+phenotype–based, and intake+phenotype+gene–based). A three-phase approach was taken: (1) existing taxonomies were reviewed and techniques were identified a priori for possible inclusion in the Food4Me study, (2) a standard operating procedure was developed to maintain consistency in the use of methods and techniques across research centers, and (3) the Food4Me behavior change technique framework was reviewed and updated post intervention. An analysis of excluded techniques was also conducted. Results Of 46 techniques identified a priori as being applicable to Food4Me, 17 were embedded in the intervention design; 11 were from a dietary taxonomy, and 6 from a smoking cessation taxonomy. In addition, the four-category smoking cessation framework structure was adopted for clarity of communication. Smoking cessation texts were adapted for dietary use where necessary. A posteriori, a further 9 techniques were included. Examination of excluded items highlighted the distinction between techniques considered appropriate for face-to-face versus internet-based delivery. Conclusions The use of existing taxonomies facilitated the description and standardization of techniques used in Food4Me. We recommend that for complex studies of this nature, technique analysis should be conducted a priori to develop standardized procedures and training and reviewed a posteriori to audit the techniques actually adopted. The present framework description makes a valuable contribution to future systematic reviews and meta-analyses that explore technique efficacy and underlying psychological constructs. This was a novel application of the behavior change taxonomies and was the first internet-based personalized nutrition intervention to use such a framework remotely. Trial Registration ClinicalTrials.gov NCT01530139; https://clinicaltrials.gov/ct2/show/NCT01530139 (Archived by WebCite at http://www.webcitation.org/6y8XYUft1) PMID:29631993

  10. Diffusion of point defects in crystalline silicon using the kinetic activation-relaxation technique method

    DOE PAGES

    Trochet, Mickaël; Béland, Laurent Karim; Joly, Jean -François; ...

    2015-06-16

    We study point-defect diffusion in crystalline silicon using the kinetic activation-relaxation technique (k-ART), an off-lattice kinetic Monte Carlo method with on-the-fly catalog building capabilities based on the activation-relaxation technique (ART nouveau), coupled to the standard Stillinger-Weber potential. We focus more particularly on the evolution of crystalline cells with one to four vacancies and one to four interstitials in order to provide a detailed picture of both the atomistic diffusion mechanisms and overall kinetics. We show formation energies, activation barriers for the ground state of all eight systems, and migration barriers for those systems that diffuse. Additionally, we characterize diffusion pathsmore » and special configurations such as dumbbell complex, di-interstitial (IV-pair+2I) superdiffuser, tetrahedral vacancy complex, and more. In conclusion, this study points to an unsuspected dynamical richness even for this apparently simple system that can only be uncovered by exhaustive and systematic approaches such as the kinetic activation-relaxation technique.« less

  11. Long-Term Maintenance of Pharmacists' Inhaler Technique Demonstration Skills

    PubMed Central

    Armour, Carol L; Reddel, Helen K; Bosnic-Anticevich, Sinthia Z

    2009-01-01

    Objective To assess the effectiveness of a single educational intervention, followed by patient education training, in pharmacists retaining their inhaler technique skills. Methods A convenience sample of 31 pharmacists attended an educational workshop and their inhaler techniques were assessed. Those randomly assigned to the active group were trained to assess and teach correct Turbuhaler and Diskus inhaler techniques to patients and provided with patient education tools to use in their pharmacies during a 6-month study. Control pharmacists delivered standard care. All pharmacists were reassessed 2 years after initial training. Results Thirty-one pharmacists participated in the study. At the initial assessment, few pharmacists demonstrated correct technique (Turbuhaler:13%, Diskus:6%). All pharmacists in the active group demonstrated correct technique following training. Two years later, pharmacists in the active group demonstrated significantly better inhaler technique than pharmacists in the control group (p < 0.05) for Turbuhaler and Diskus (83% vs.11%; 75% vs.11%, respectively). Conclusion Providing community pharmacists with effective patient education tools and encouraging their involvement in educating patients may contribute to pharmacists maintaining their competence in correct inhaler technique long-term. PMID:19513170

  12. Align-and-shine photolithography

    NASA Astrophysics Data System (ADS)

    Petrusis, Audrius; Rector, Jan H.; Smith, Kristen; de Man, Sven; Iannuzzi, Davide

    2009-10-01

    At the beginning of 2009, our group has introduced a new technique that allows fabrication of photolithographic patterns on the cleaved end of an optical fibre: the align-and-shine photolithography technique (see A. Petrušis et al., "The align-and-shine technique for series production of photolithography patterns on optical fibres", J. Micromech. Microeng. 19, 047001, 2009). Align-and-shine photolithography combines standard optical lithography with imagebased active fibre alignment processes. The technique adapts well to series production, opening the way to batch fabrication of fibre-top devices (D. Iannuzzi et al., "Monolithic fibre-top cantilever for critical environments and standard applications", Appl. Phys. Lett. 88, 053501, 2006) and all other devices that rely on suitable machining of engineered parts on the tip of a fibre. In this paper we review our results and briefly discuss its potential applications.

  13. Exercising for Two. What's Safe for the Active Pregnant Woman?

    ERIC Educational Resources Information Center

    White, Jacqueline

    1992-01-01

    Clinical experience and recent research challenge the current standards of exercise duration and intensity for pregnant women. By carefully assessing patients' self-monitoring techniques, physicians can work with active women to create safe exercise programs during pregnancy. Safety guidelines for developing home exercise programs are included.…

  14. Methodological integrative review of the work sampling technique used in nursing workload research.

    PubMed

    Blay, Nicole; Duffield, Christine M; Gallagher, Robyn; Roche, Michael

    2014-11-01

    To critically review the work sampling technique used in nursing workload research. Work sampling is a technique frequently used by researchers and managers to explore and measure nursing activities. However, work sampling methods used are diverse making comparisons of results between studies difficult. Methodological integrative review. Four electronic databases were systematically searched for peer-reviewed articles published between 2002-2012. Manual scanning of reference lists and Rich Site Summary feeds from contemporary nursing journals were other sources of data. Articles published in the English language between 2002-2012 reporting on research which used work sampling to examine nursing workload. Eighteen articles were reviewed. The review identified that the work sampling technique lacks a standardized approach, which may have an impact on the sharing or comparison of results. Specific areas needing a shared understanding included the training of observers and subjects who self-report, standardization of the techniques used to assess observer inter-rater reliability, sampling methods and reporting of outcomes. Work sampling is a technique that can be used to explore the many facets of nursing work. Standardized reporting measures would enable greater comparison between studies and contribute to knowledge more effectively. Author suggestions for the reporting of results may act as guidelines for researchers considering work sampling as a research method. © 2014 John Wiley & Sons Ltd.

  15. Comparison of active-set method deconvolution and matched-filtering for derivation of an ultrasound transit time spectrum.

    PubMed

    Wille, M-L; Zapf, M; Ruiter, N V; Gemmeke, H; Langton, C M

    2015-06-21

    The quality of ultrasound computed tomography imaging is primarily determined by the accuracy of ultrasound transit time measurement. A major problem in analysis is the overlap of signals making it difficult to detect the correct transit time. The current standard is to apply a matched-filtering approach to the input and output signals. This study compares the matched-filtering technique with active set deconvolution to derive a transit time spectrum from a coded excitation chirp signal and the measured output signal. The ultrasound wave travels in a direct and a reflected path to the receiver, resulting in an overlap in the recorded output signal. The matched-filtering and deconvolution techniques were applied to determine the transit times associated with the two signal paths. Both techniques were able to detect the two different transit times; while matched-filtering has a better accuracy (0.13 μs versus 0.18 μs standard deviations), deconvolution has a 3.5 times improved side-lobe to main-lobe ratio. A higher side-lobe suppression is important to further improve image fidelity. These results suggest that a future combination of both techniques would provide improved signal detection and hence improved image fidelity.

  16. A new polarimetric active radar calibrator and calibration technique

    NASA Astrophysics Data System (ADS)

    Tang, Jianguo; Xu, Xiaojian

    2015-10-01

    Polarimetric active radar calibrator (PARC) is one of the most important calibrators with high radar cross section (RCS) for polarimetry measurement. In this paper, a new double-antenna polarimetric active radar calibrator (DPARC) is proposed, which consists of two rotatable antennas with wideband electromagnetic polarization filters (EMPF) to achieve lower cross-polarization for transmission and reception. With two antennas which are rotatable around the radar line of sight (LOS), the DPARC provides a variety of standard polarimetric scattering matrices (PSM) through the rotation combination of receiving and transmitting polarization, which are useful for polarimatric calibration in different applications. In addition, a technique based on Fourier analysis is proposed for calibration processing. Numerical simulation results are presented to demonstrate the superior performance of the proposed DPARC and processing technique.

  17. Calibration of High Heat Flux Sensors at NIST

    PubMed Central

    Murthy, A. V.; Tsai, B. K.; Gibson, C. E.

    1997-01-01

    An ongoing program at the National Institute of Standards and Technology (NIST) is aimed at improving and standardizing heat-flux sensor calibration methods. The current calibration needs of U.S. science and industry exceed the current NIST capability of 40 kW/m2 irradiance. In achieving this goal, as well as meeting lower-level non-radiative heat flux calibration needs of science and industry, three different types of calibration facilities currently are under development at NIST: convection, conduction, and radiation. This paper describes the research activities associated with the NIST Radiation Calibration Facility. Two different techniques, transfer and absolute, are presented. The transfer calibration technique employs a transfer standard calibrated with reference to a radiometric standard for calibrating the sensors using a graphite tube blackbody. Plans for an absolute calibration facility include the use of a spherical blackbody and a cooled aperture and sensor-housing assembly to calibrate the sensors in a low convective environment. PMID:27805156

  18. Performance evaluation of the atmospheric phase of aeromaneuvering orbital transfer vehicles

    NASA Technical Reports Server (NTRS)

    Powell, R. W.; Stone, H. W.; Naftel, J. C.

    1984-01-01

    Studies are underway to design reusable orbital transfer vehicles that would be used to transfer payloads from low-earth orbit to higher orbits and return. One promising concept is to use an atmospheric pass on the return leg to reduce the amount of fuel for the mission. This paper discusses a six-degree-of-freedom simulation analysis for two configurations, a low-lift-to-drag ratio configuration and a medium-lift-to-drag ratio configuration using both a predictive guidance technique and an adaptive guidance technique. Both guidance schemes were evaluated using the 1962 standard atmosphere and three atmospheres that had been derived from three entries of the Space Shuttle. The predictive technique requires less reaction control system activity for both configurations, but because of the limited number of updates and because each update used the 1962 standard atmosphere, the adaptive technique produces more accurate exit conditions.

  19. Measuring the activity of BioBrick promoters using an in vivo reference standard

    PubMed Central

    Kelly, Jason R; Rubin, Adam J; Davis, Joseph H; Ajo-Franklin, Caroline M; Cumbers, John; Czar, Michael J; de Mora, Kim; Glieberman, Aaron L; Monie, Dileep D; Endy, Drew

    2009-01-01

    Background The engineering of many-component, synthetic biological systems is being made easier by the development of collections of reusable, standard biological parts. However, the complexity of biology makes it difficult to predict the extent to which such efforts will succeed. As a first practical example, the Registry of Standard Biological Parts started at MIT now maintains and distributes thousands of BioBrick™ standard biological parts. However, BioBrick parts are only standardized in terms of how individual parts are physically assembled into multi-component systems, and most parts remain uncharacterized. Standardized tools, techniques, and units of measurement are needed to facilitate the characterization and reuse of parts by independent researchers across many laboratories. Results We found that the absolute activity of BioBrick promoters varies across experimental conditions and measurement instruments. We choose one promoter (BBa_J23101) to serve as an in vivo reference standard for promoter activity. We demonstrated that, by measuring the activity of promoters relative to BBa_J23101, we could reduce variation in reported promoter activity due to differences in test conditions and measurement instruments by ~50%. We defined a Relative Promoter Unit (RPU) in order to report promoter characterization data in compatible units and developed a measurement kit so that researchers might more easily adopt RPU as a standard unit for reporting promoter activity. We distributed a set of test promoters to multiple labs and found good agreement in the reported relative activities of promoters so measured. We also characterized the relative activities of a reference collection of BioBrick promoters in order to further support adoption of RPU-based measurement standards. Conclusion Relative activity measurements based on an in vivoreference standard enables improved measurement of promoter activity given variation in measurement conditions and instruments. These improvements are sufficient to begin to support the measurement of promoter activities across many laboratories. Additional in vivo reference standards for other types of biological functions would seem likely to have similar utility, and could thus improve research on the design, production, and reuse of standard biological parts. PMID:19298678

  20. 76 FR 26319 - Agency Information Collection Activities: Proposed Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-06

    ... Based Standard for Fire Protection for Light Water Reactor Electric Generating Plants, 2001 Edition... techniques or other forms of information technology? The public may examine and have copied, for a fee...

  1. Current activities in standardization of high-temperature, low-cycle-fatigue testing techniques in the United States

    NASA Technical Reports Server (NTRS)

    Verrilli, Michael J.; Ellis, J. Rodney; Swindeman, Robert W.

    1990-01-01

    The American Society for Testing and Materials (ASTM) standard E606-80 is the most often used recommended testing practice for low-cycle-fatigue (LCF) testing in the United States. The standard was first adopted in 1977 for LCF testing at room temperature and was modified in 1980 to include high-temperature testing practices. Current activity within ASTM is aimed at extending the E606-80 recommended practices to LCF under thermomechanical conditions, LCF in high-pressure hydrogen, and LCF in metal-matrix composite materials. Interlaboratory testing programs conducted to generate a technical base for modifying E606-80 for the aforementioned LCF test types are discussed.

  2. Development of a new test cell to measure cumulative permeation of water-insoluble pesticides with low vapor pressure through protective clothing and glove materials

    PubMed Central

    SHAW, Anugrah; COLEONE-CARVALHO, Ana Carla; HOLLINGSHURST, Julien; DRAPER, Michael; MACHADO NETO, Joaquim Gonçalves

    2017-01-01

    A collaborative approach, involving resources and expertise from several countries, was used to develop a test cell to measure cumulative permeation by a solid-state collection technique. The new technique was developed to measure the permeation of pesticide active ingredients and other chemicals with low vapor pressure that would otherwise be difficult to test via standard techniques. The development process is described and the results from the final chosen test method are reported. Inter-laboratory studies were conducted to further refine the new method and determine repeatability and reliability. The revised test method has been approved as a new ISO/EN standard to measure permeation of chemicals with low vapor pressure and/or solubility in water. PMID:29033403

  3. A study of trends and techniques for space base electronics

    NASA Technical Reports Server (NTRS)

    Trotter, J. D.; Wade, T. E.; Gassaway, J. D.

    1978-01-01

    Furnaces and photolithography related equipment were applied to experiments on double layer metal. The double layer metal activity emphasized wet chemistry techniques. By incorporating the following techniques: (1) ultrasonic etching of the vias; (2) premetal clean using a modified buffered hydrogen fluoride; (3) phosphorus doped vapor; and (4) extended sintering, yields of 98 percent were obtained using the standard test pattern. The two dimensional modeling problems have stemmed from, alternately, instability and too much computation time to achieve convergence.

  4. New mechanistic insights in the NH 3-SCR reactions at low temperature

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ruggeri, Maria Pia; Selleri, Tomasso; Nova, Isabella

    2016-05-06

    The present study is focused on the investigation of the low temperature Standard SCR reaction mechanism over Fe- and Cu-promoted zeolites. Different techniques are employed, including in situ DRIFTS, transient reaction analysis and chemical trapping techniques. The results present strong evidence of nitrite formation in the oxidative activation of NO and of their role in SCR reactions. These elements lead to a deeper understanding of the standard SCR chemistry at low temperature and can potentially improve the consistency of mechanistic mathematical models. Furthermore, comprehension of the mechanism on a fundamental level can contribute to the development of improved SCR catalysts.

  5. [Bus drivers' biomechanical risk assessment in two different contexts].

    PubMed

    Baracco, A; Coggiola, M; Perrelli, F; Banchio, M; Martignone, S; Gullino, A; Romano, C

    2012-01-01

    The application of standardize methods for the biomechanical risk assessment in non-industrial cycled activity is not always possible. A typical case is the public transport sector, where workers complain of suffering for shoulder more than elbow and wrist pains. The Authors present the results of two studies involving two public transport companies and the risk of biomechanical overload of upper limbs for bus and tram drivers. The analysis has been made using three different approaches: focus groups; static analysis by using anthropometric manikins; work sampling technique by monitoring worker's activity and posture at each minute, for two hours and for each binomial vehicle-route, considering P5F e P95M drivers and assessing the perceived efforts thorough the Borg's CR10 Scale. The conclusive results show that the ergonomic analysis managed by multiple non-standardized techniques may reach consistent and repeatable results according to the epidemiological evidences.

  6. Toward energy harvesting using active materials and conversion improvement by nonlinear processing.

    PubMed

    Guyomar, Daniel; Badel, Adrien; Lefeuvre, Elie; Richard, Claude

    2005-04-01

    This paper presents a new technique of electrical energy generation using mechanically excited piezoelectric materials and a nonlinear process. This technique, called synchronized switch harvesting (SSH), is derived from the synchronized switch damping (SSD), which is a nonlinear technique previously developed to address the problem of vibration damping on mechanical structures. This technique results in a significant increase of the electromechanical conversion capability of piezoelectric materials. Comparatively with standard technique, the electrical harvested power may be increased above 900%. The performance of the nonlinear processing is demonstrated on structures excited at their resonance frequency as well as out of resonance.

  7. Application of Behavior Change Techniques in a Personalized Nutrition Electronic Health Intervention Study: Protocol for the Web-Based Food4Me Randomized Controlled Trial.

    PubMed

    Macready, Anna L; Fallaize, Rosalind; Butler, Laurie T; Ellis, Judi A; Kuznesof, Sharron; Frewer, Lynn J; Celis-Morales, Carlos; Livingstone, Katherine M; Araújo-Soares, Vera; Fischer, Arnout Rh; Stewart-Knox, Barbara J; Mathers, John C; Lovegrove, Julie A

    2018-04-09

    To determine the efficacy of behavior change techniques applied in dietary and physical activity intervention studies, it is first necessary to record and describe techniques that have been used during such interventions. Published frameworks used in dietary and smoking cessation interventions undergo continuous development, and most are not adapted for Web-based delivery. The Food4Me study (N=1607) provided the opportunity to use existing frameworks to describe standardized Web-based techniques employed in a large-scale, internet-based intervention to change dietary behavior and physical activity. The aims of this study were (1) to describe techniques embedded in the Food4Me study design and explain the selection rationale and (2) to demonstrate the use of behavior change technique taxonomies, develop standard operating procedures for training, and identify strengths and limitations of the Food4Me framework that will inform its use in future studies. The 6-month randomized controlled trial took place simultaneously in seven European countries, with participants receiving one of four levels of personalized advice (generalized, intake-based, intake+phenotype-based, and intake+phenotype+gene-based). A three-phase approach was taken: (1) existing taxonomies were reviewed and techniques were identified a priori for possible inclusion in the Food4Me study, (2) a standard operating procedure was developed to maintain consistency in the use of methods and techniques across research centers, and (3) the Food4Me behavior change technique framework was reviewed and updated post intervention. An analysis of excluded techniques was also conducted. Of 46 techniques identified a priori as being applicable to Food4Me, 17 were embedded in the intervention design; 11 were from a dietary taxonomy, and 6 from a smoking cessation taxonomy. In addition, the four-category smoking cessation framework structure was adopted for clarity of communication. Smoking cessation texts were adapted for dietary use where necessary. A posteriori, a further 9 techniques were included. Examination of excluded items highlighted the distinction between techniques considered appropriate for face-to-face versus internet-based delivery. The use of existing taxonomies facilitated the description and standardization of techniques used in Food4Me. We recommend that for complex studies of this nature, technique analysis should be conducted a priori to develop standardized procedures and training and reviewed a posteriori to audit the techniques actually adopted. The present framework description makes a valuable contribution to future systematic reviews and meta-analyses that explore technique efficacy and underlying psychological constructs. This was a novel application of the behavior change taxonomies and was the first internet-based personalized nutrition intervention to use such a framework remotely. ClinicalTrials.gov NCT01530139; https://clinicaltrials.gov/ct2/show/NCT01530139 (Archived by WebCite at http://www.webcitation.org/6y8XYUft1). ©Anna L Macready, Rosalind Fallaize, Laurie T Butler, Judi A Ellis, Sharron Kuznesof, Lynn J Frewer, Carlos Celis-Morales, Katherine M Livingstone, Vera Araújo-Soares, Arnout RH Fischer, Barbara J Stewart-Knox, John C Mathers, Julie A Lovegrove. Originally published in JMIR Research Protocols (http://www.researchprotocols.org), 09.04.2018.

  8. Evaluation of Am–Li neutron spectra data for active well type neutron multiplicity measurements of uranium

    DOE PAGES

    Goddard, Braden; Croft, Stephen; Lousteau, Angela; ...

    2016-05-25

    Safeguarding nuclear material is an important and challenging task for the international community. One particular safeguards technique commonly used for uranium assay is active neutron correlation counting. This technique involves irradiating unused uranium with ( α,n) neutrons from an Am-Li source and recording the resultant neutron pulse signal which includes induced fission neutrons. Although this non-destructive technique is widely employed in safeguards applications, the neutron energy spectra from an Am-Li sources is not well known. Several measurements over the past few decades have been made to characterize this spectrum; however, little work has been done comparing the measured spectra ofmore » various Am-Li sources to each other. This paper examines fourteen different Am-Li spectra, focusing on how these spectra affect simulated neutron multiplicity results using the code Monte Carlo N-Particle eXtended (MCNPX). Two measurement and simulation campaigns were completed using Active Well Coincidence Counter (AWCC) detectors and uranium standards of varying enrichment. The results of this work indicate that for standard AWCC measurements, the fourteen Am-Li spectra produce similar doubles and triples count rates. Finally, the singles count rates varied by as much as 20% between the different spectra, although they are usually not used in quantitative analysis.« less

  9. An emerging network storage management standard: Media error monitoring and reporting information (MEMRI) - to determine optical tape data integrity

    NASA Technical Reports Server (NTRS)

    Podio, Fernando; Vollrath, William; Williams, Joel; Kobler, Ben; Crouse, Don

    1998-01-01

    Sophisticated network storage management applications are rapidly evolving to satisfy a market demand for highly reliable data storage systems with large data storage capacities and performance requirements. To preserve a high degree of data integrity, these applications must rely on intelligent data storage devices that can provide reliable indicators of data degradation. Error correction activity generally occurs within storage devices without notification to the host. Early indicators of degradation and media error monitoring 333 and reporting (MEMR) techniques implemented in data storage devices allow network storage management applications to notify system administrators of these events and to take appropriate corrective actions before catastrophic errors occur. Although MEMR techniques have been implemented in data storage devices for many years, until 1996 no MEMR standards existed. In 1996 the American National Standards Institute (ANSI) approved the only known (world-wide) industry standard specifying MEMR techniques to verify stored data on optical disks. This industry standard was developed under the auspices of the Association for Information and Image Management (AIIM). A recently formed AIIM Optical Tape Subcommittee initiated the development of another data integrity standard specifying a set of media error monitoring tools and media error monitoring information (MEMRI) to verify stored data on optical tape media. This paper discusses the need for intelligent storage devices that can provide data integrity metadata, the content of the existing data integrity standard for optical disks, and the content of the MEMRI standard being developed by the AIIM Optical Tape Subcommittee.

  10. Towards neural correlates of auditory stimulus processing: A simultaneous auditory evoked potentials and functional magnetic resonance study using an odd-ball paradigm

    PubMed Central

    Milner, Rafał; Rusiniak, Mateusz; Lewandowska, Monika; Wolak, Tomasz; Ganc, Małgorzata; Piątkowska-Janko, Ewa; Bogorodzki, Piotr; Skarżyński, Henryk

    2014-01-01

    Background The neural underpinnings of auditory information processing have often been investigated using the odd-ball paradigm, in which infrequent sounds (deviants) are presented within a regular train of frequent stimuli (standards). Traditionally, this paradigm has been applied using either high temporal resolution (EEG) or high spatial resolution (fMRI, PET). However, used separately, these techniques cannot provide information on both the location and time course of particular neural processes. The goal of this study was to investigate the neural correlates of auditory processes with a fine spatio-temporal resolution. A simultaneous auditory evoked potentials (AEP) and functional magnetic resonance imaging (fMRI) technique (AEP-fMRI), together with an odd-ball paradigm, were used. Material/Methods Six healthy volunteers, aged 20–35 years, participated in an odd-ball simultaneous AEP-fMRI experiment. AEP in response to acoustic stimuli were used to model bioelectric intracerebral generators, and electrophysiological results were integrated with fMRI data. Results fMRI activation evoked by standard stimuli was found to occur mainly in the primary auditory cortex. Activity in these regions overlapped with intracerebral bioelectric sources (dipoles) of the N1 component. Dipoles of the N1/P2 complex in response to standard stimuli were also found in the auditory pathway between the thalamus and the auditory cortex. Deviant stimuli induced fMRI activity in the anterior cingulate gyrus, insula, and parietal lobes. Conclusions The present study showed that neural processes evoked by standard stimuli occur predominantly in subcortical and cortical structures of the auditory pathway. Deviants activate areas non-specific for auditory information processing. PMID:24413019

  11. Curve fitting air sample filter decay curves to estimate transuranic content.

    PubMed

    Hayes, Robert B; Chiou, Hung Cheng

    2004-01-01

    By testing industry standard techniques for radon progeny evaluation on air sample filters, a new technique is developed to evaluate transuranic activity on air filters by curve fitting the decay curves. The industry method modified here is simply the use of filter activity measurements at different times to estimate the air concentrations of radon progeny. The primary modification was to not look for specific radon progeny values but rather transuranic activity. By using a method that will provide reasonably conservative estimates of the transuranic activity present on a filter, some credit for the decay curve shape can then be taken. By carrying out rigorous statistical analysis of the curve fits to over 65 samples having no transuranic activity taken over a 10-mo period, an optimization of the fitting function and quality tests for this purpose was attained.

  12. Segmented Gamma Scanner for Small Containers of Uranium Processing Waste- 12295

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morris, K.E.; Smith, S.K.; Gailey, S.

    2012-07-01

    The Segmented Gamma Scanner (SGS) is commonly utilized in the assay of 55-gallon drums containing radioactive waste. Successfully deployed calibration methods include measurement of vertical line source standards in representative matrices and mathematical efficiency calibrations. The SGS technique can also be utilized to assay smaller containers, such as those used for criticality safety in uranium processing facilities. For such an application, a Can SGS System is aptly suited for the identification and quantification of radionuclides present in fuel processing wastes. Additionally, since the significant presence of uranium lumping can confound even a simple 'pass/fail' measurement regimen, the high-resolution gamma spectroscopymore » allows for the use of lump-detection techniques. In this application a lump correction is not required, but the application of a differential peak approach is used to simply identify the presence of U-235 lumps. The Can SGS is similar to current drum SGSs, but differs in the methodology for vertical segmentation. In the current drum SGS, the drum is placed on a rotator at a fixed vertical position while the detector, collimator, and transmission source are moved vertically to effect vertical segmentation. For the Can SGS, segmentation is more efficiently done by raising and lowering the rotator platform upon which the small container is positioned. This also reduces the complexity of the system mechanism. The application of the Can SGS introduces new challenges to traditional calibration and verification approaches. In this paper, we revisit SGS calibration methodology in the context of smaller waste containers, and as applied to fuel processing wastes. Specifically, we discuss solutions to the challenges introduced by requiring source standards to fit within the confines of the small containers and the unavailability of high-enriched uranium source standards. We also discuss the implementation of a previously used technique for identifying the presence of uranium lumping. The SGS technique is a well-accepted NDA technique applicable to containers of almost any size. It assumes a homogenous matrix and activity distribution throughout the entire container; an assumption that is at odds with the detection of lumps within the assay item typical of uranium-processing waste. This fact, in addition to the difficultly in constructing small reference standards of uranium-bearing materials, required the methodology used for performing an efficiency curve calibration to be altered. The solution discussed in this paper is demonstrated to provide good results for both the segment activity and full container activity when measuring heterogeneous source distributions. The application of this approach will need to be based on process knowledge of the assay items, as biases can be introduced if used with homogenous, or nearly homogenous, activity distributions. The bias will need to be quantified for each combination of container geometry and SGS scanning settings. One recommended approach for using the heterogeneous calibration discussed here is to assay each item using a homogenous calibration initially. Review of the segment activities compared to the full container activity will signal the presence of a non-uniform activity distribution as the segment activity will be grossly disproportionate to the full container activity. Upon seeing this result, the assay should either be reanalyzed or repeated using the heterogeneous calibration. (authors)« less

  13. Localized analysis of paint-coat drying using dynamic speckle interferometry

    NASA Astrophysics Data System (ADS)

    Sierra-Sosa, Daniel; Tebaldi, Myrian; Grumel, Eduardo; Rabal, Hector; Elmaghraby, Adel

    2018-07-01

    The paint-coating is part of several industrial processes, including the automotive industry, architectural coatings, machinery and appliances. These paint-coatings must comply with high quality standards, for this reason evaluation techniques from paint-coatings are in constant development. One important factor from the paint-coating process is the drying, as it has influence on the quality of final results. In this work we present an assessment technique based on the optical dynamic speckle interferometry, this technique allows for the temporal activity evaluation of the paint-coating drying process, providing localized information from drying. This localized information is relevant in order to address the drying homogeneity, optimal drying, and quality control. The technique relies in the definition of a new temporal history of the speckle patterns to obtain the local activity; this information is then clustered to provide a convenient indicative of different drying process stages. The experimental results presented were validated using the gravimetric drying curves

  14. Surface texture measurement for dental wear applications

    NASA Astrophysics Data System (ADS)

    Austin, R. S.; Mullen, F.; Bartlett, D. W.

    2015-06-01

    The application of surface topography measurement and characterization within dental materials science is highly active and rapidly developing, in line with many modern industries. Surface measurement and structuring is used extensively within oral and dental science to optimize the optical, tribological and biological performance of natural and biomimetic dental materials. Although there has historically been little standardization in the use and reporting of surface metrology instrumentation and software, the dental industry is beginning to adopt modern areal measurement and characterization techniques, especially as the dental industry is increasingly adopting digital impressioning techniques in order to leverage CAD/CAM technologies for the design and construction of dental restorations. As dental treatment becomes increasingly digitized and reliant on advanced technologies such as dental implants, wider adoption of standardized surface topography and characterization techniques will become evermore essential. The dental research community welcomes the advances that are being made in surface topography measurement science towards realizing this ultimate goal.

  15. Model-Based Data Integration and Process Standardization Techniques for Fault Management: A Feasibility Study

    NASA Technical Reports Server (NTRS)

    Haste, Deepak; Ghoshal, Sudipto; Johnson, Stephen B.; Moore, Craig

    2018-01-01

    This paper describes the theory and considerations in the application of model-based techniques to assimilate information from disjoint knowledge sources for performing NASA's Fault Management (FM)-related activities using the TEAMS® toolset. FM consists of the operational mitigation of existing and impending spacecraft failures. NASA's FM directives have both design-phase and operational-phase goals. This paper highlights recent studies by QSI and DST of the capabilities required in the TEAMS® toolset for conducting FM activities with the aim of reducing operating costs, increasing autonomy, and conforming to time schedules. These studies use and extend the analytic capabilities of QSI's TEAMS® toolset to conduct a range of FM activities within a centralized platform.

  16. Tracking variations in the alpha activity in an electroencephalogram

    NASA Technical Reports Server (NTRS)

    Prabhu, K. S.

    1971-01-01

    The problem of tracking Alpha voltage variations in an electroencephalogram is discussed. This problem is important in encephalographic studies of sleep and effects of different stimuli on the brain. Very often the Alpha voltage is tracked by passing the EEG signal through a bandpass filter centered at the Alpha frequency, which hopefully will filter out unwanted noise from the Alpha activity. Some alternative digital techniques are suggested and their performance is compared with the standard technique. These digital techniques can be used in an environment where an electroencephalograph is interfaced with a small digital computer via an A/D convertor. They have the advantage that statistical statements about their variability can sometimes be made so that the effect sought can be assessed correctly in the presence of random fluctuations.

  17. Mapping brain activity in gradient-echo functional MRI using principal component analysis

    NASA Astrophysics Data System (ADS)

    Khosla, Deepak; Singh, Manbir; Don, Manuel

    1997-05-01

    The detection of sites of brain activation in functional MRI has been a topic of immense research interest and many technique shave been proposed to this end. Recently, principal component analysis (PCA) has been applied to extract the activated regions and their time course of activation. This method is based on the assumption that the activation is orthogonal to other signal variations such as brain motion, physiological oscillations and other uncorrelated noises. A distinct advantage of this method is that it does not require any knowledge of the time course of the true stimulus paradigm. This technique is well suited to EPI image sequences where the sampling rate is high enough to capture the effects of physiological oscillations. In this work, we propose and apply tow methods that are based on PCA to conventional gradient-echo images and investigate their usefulness as tools to extract reliable information on brain activation. The first method is a conventional technique where a single image sequence with alternating on and off stages is subject to a principal component analysis. The second method is a PCA-based approach called the common spatial factor analysis technique (CSF). As the name suggests, this method relies on common spatial factors between the above fMRI image sequence and a background fMRI. We have applied these methods to identify active brain ares during visual stimulation and motor tasks. The results from these methods are compared to those obtained by using the standard cross-correlation technique. We found good agreement in the areas identified as active across all three techniques. The results suggest that PCA and CSF methods have good potential in detecting the true stimulus correlated changes in the presence of other interfering signals.

  18. Standardization of 64Cu using an improved decay scheme

    NASA Astrophysics Data System (ADS)

    Amiot, M. N.; Bé, M. M.; Branger, T.; Cassette, P.; Lépy, M. C.; Ménesguen, Y.; Da Silva, I.

    2012-08-01

    A 64Cu solution was standardized by means of liquid scintillation counting. The activity of the solution was also determined with an ionization chamber whose response was simulated by using a Monte Carlo code. The photon emission intensities including K X-rays were determined to be I511=35.1 (3)%; I1346=0.472 (12)%, IKα=14.41 (15)%, IKβ=2.01 (3)%, respectively. 64Cu half-life was also determined as 12.718 (23) h. The new decay scheme used in the present work was established following the EURAMET 1085 exercise where a good agreement between activity measurement techniques was found.

  19. Prediction of activity type in preschool children using machine learning techniques.

    PubMed

    Hagenbuchner, Markus; Cliff, Dylan P; Trost, Stewart G; Van Tuc, Nguyen; Peoples, Gregory E

    2015-07-01

    Recent research has shown that machine learning techniques can accurately predict activity classes from accelerometer data in adolescents and adults. The purpose of this study is to develop and test machine learning models for predicting activity type in preschool-aged children. Participants completed 12 standardised activity trials (TV, reading, tablet game, quiet play, art, treasure hunt, cleaning up, active game, obstacle course, bicycle riding) over two laboratory visits. Eleven children aged 3-6 years (mean age=4.8±0.87; 55% girls) completed the activity trials while wearing an ActiGraph GT3X+ accelerometer on the right hip. Activities were categorised into five activity classes: sedentary activities, light activities, moderate to vigorous activities, walking, and running. A standard feed-forward Artificial Neural Network and a Deep Learning Ensemble Network were trained on features in the accelerometer data used in previous investigations (10th, 25th, 50th, 75th and 90th percentiles and the lag-one autocorrelation). Overall recognition accuracy for the standard feed forward Artificial Neural Network was 69.7%. Recognition accuracy for sedentary activities, light activities and games, moderate-to-vigorous activities, walking, and running was 82%, 79%, 64%, 36% and 46%, respectively. In comparison, overall recognition accuracy for the Deep Learning Ensemble Network was 82.6%. For sedentary activities, light activities and games, moderate-to-vigorous activities, walking, and running recognition accuracy was 84%, 91%, 79%, 73% and 73%, respectively. Ensemble machine learning approaches such as Deep Learning Ensemble Network can accurately predict activity type from accelerometer data in preschool children. Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  20. In-lab versus at-home activity recognition in ambulatory subjects with incomplete spinal cord injury.

    PubMed

    Albert, Mark V; Azeze, Yohannes; Courtois, Michael; Jayaraman, Arun

    2017-02-06

    Although commercially available activity trackers can aid in tracking therapy and recovery of patients, most devices perform poorly for patients with irregular movement patterns. Standard machine learning techniques can be applied on recorded accelerometer signals in order to classify the activities of ambulatory subjects with incomplete spinal cord injury in a way that is specific to this population and the location of the recording-at home or in the clinic. Subjects were instructed to perform a standardized set of movements while wearing a waist-worn accelerometer in the clinic and at-home. Activities included lying, sitting, standing, walking, wheeling, and stair climbing. Multiple classifiers and validation methods were used to quantify the ability of the machine learning techniques to distinguish the activities recorded in-lab or at-home. In the lab, classifiers trained and tested using within-subject cross-validation provided an accuracy of 91.6%. When the classifier was trained on data collected in the lab but tested on at home data, the accuracy fell to 54.6% indicating distinct movement patterns between locations. However, the accuracy of the at-home classifications, when training the classifier with at-home data, improved to 85.9%. Individuals with unique movement patterns can benefit from using tailored activity recognition algorithms easily implemented using modern machine learning methods on collected movement data.

  1. Active silicone oil removal with a modified vacuum syringe.

    PubMed

    Bajaire, Boris J; Oudovitchenko, Elena; Salguero, Andrés E; Paipilla, Diego F

    2012-01-01

    At present, the number of clinical indications for the use of silicone oil (SO) has increased in intraocular surgery because of the advent of new techniques in vitreoretinal surgery, availability of better quality oils, and greater experience in its use. Consequently, the number of procedures for SO removal has increased, and support technologies for these procedures are always a concern. A simple active technique for SO removal based on a 5-mL standard syringe with an 18G cannula was developed. The oil is suctioned into the syringe by the pulling effect of a spring assembled along the axis of the piston. No abrupt change in the intraocular pressure is produced because of the oil viscosity and the reduced diameter of the cannula. A technique for SO removal that has been used successfully during the past 7 years is presented in this article. During the 7-year period, 234 SO removals were performed without any complication or device failure. Using the present method, the average time for SO removal was 4 minutes. The average extraction time with the technique is 4 minutes, which is in the range of other active techniques, and it is faster than passive methods that are performed between 8 and 9 minutes. The technique is in line with the advantages of more elaborated active methods without using complex technology. It is considered to be highly successful and easy to implement.

  2. Equations with Parameters: A Locus Approach

    ERIC Educational Resources Information Center

    Abramovich, Sergei; Norton, Anderson

    2006-01-01

    This paper introduces technology-based teaching ideas that facilitate the development of qualitative reasoning techniques in the context of quadratic equations with parameters. It reflects on activities designed for and used with prospective secondary mathematics teachers in accord with standards for teaching and recommendations for teachers in…

  3. Restoration of bladder function in spastic neuropathic bladder using sacral deafferentation and different techniques of neurostimulation.

    PubMed

    Schumacher, S; Bross, S; Scheepe, J R; Alken, P; Jünemann, K P

    1999-01-01

    Conventional sacral anterior root stimulation (SARS) results in simultaneous activation of both the detrusor muscle and the external urethral sphincter. We evaluated the possibilities of different neurostimulation techniques to overcome stimulation induced detrusor-sphincter-dyssynergia and to achieve a physiological voiding. The literature was reviewed on different techniques of sacral anterior root stimulation of the bladder and the significance of posterior rhizotomy in patients with supraconal spinal cord injury suffering from the loss of voluntary bladder control, detrusor hyperreflexia and sphincter spasm. The achievement of selective detrusor activation would improve current sacral neurostimulation of the bladder, including the principle of "poststimulus voiding". This is possible with the application of selective neurostimulation in techniques of anodal block, high frequency block, depolarizing prepulses and cold block. Nowadays, sacral deafferentation is a standard therapy in combination with neurostimulation of the bladder because in conclusion advantages of complete rhizotomy predominate. The combination of sacral anterior root stimulation and sacral deafferentation is a successful procedure for restoration of bladder function in patients with supraconal spinal cord injury. Anodal block technique and cryotechnique are excellent methods for selective bladder activation to avoid detrusor-sphincter-dyssynergia and thus improve stimulation induced voiding.

  4. Standardization of ¹³¹I: implementation of CIEMAT/NIST method at BARC, India.

    PubMed

    Kulkarni, D B; Anuradha, R; Reddy, P J; Joseph, Leena

    2011-10-01

    The CIEMAT/NIST efficiency tracing method using ³H standard was implemented at Radiation Safety Systems Division, Bhabha Atomic Research Centre (BARC) for the standardization of ¹³¹I radioactive solution. Measurements were also carried out using the 4π β-γ coincidence counting system maintained as a primary standard at the laboratory. The implementation of the CIEMAT/NIST method was verified by comparing the activity concentration obtained in the laboratory with that of the average value of the APMP intercomparison (Yunoki et al., in progress, (APMP.RI(II)-K2.I-131)). The results obtained by the laboratory is linked to the CIPM Key Comparison Reference Value (KCRV) through the equivalent activity value of National Metrology Institute of Japan (NMIJ) (Yunoki et al., in progress, (APMP.RI(II)-K2.I-131)), which was the pilot laboratory for the intercomparison. The procedure employed to standardize ¹³¹I by the CIEMAT/NIST efficiency tracing technique is presented. The activity concentrations obtained have been normalized with the activity concentration measured by NMIJ to maintain confidentiality of results until the Draft-A report is accepted by all participants. The normalized activity concentrations obtained with the CIEMAT/NIST method was 0.9985 ± 0.0035 kBq/g and using 4π β-γ coincidence counting method was 0.9909 ± 0.0046 kBq/g as on 20 March 2009, 0 h UTC. The normalized activity concentration measured by the NMIJ was 1 ± 0.0024 kBq/g. The normalized average of the activity concentrations of all the participating laboratories was 1.004 ± 0.028 kBq/g. The results obtained in the laboratory are comparable with the other international standards within the uncertainty limits. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. Early Patient Outcomes After Primary Total Knee Arthroplasty with Quadriceps-Sparing Subvastus and Medial Parapatellar Techniques

    PubMed Central

    Tomek, Ivan M.; Kantor, Stephen R.; Cori, LuAnne A.; Scoville, Jennifer M.; Grove, Margaret R.; Morgan, Tamara S.; Swarup, Ishaan; Moschetti, Wayne E.; Spratt, Kevin F.

    2014-01-01

    Background: Techniques that reduce injury to the knee extensor mechanism may cause less pain and allow faster recovery of knee function after primary total knee arthroplasty. A quadriceps-sparing (QS) subvastus technique of total knee arthroplasty was compared with medial parapatellar arthrotomy (MPPA) to determine which surgical technique led to better patient-reported function and less postoperative pain and opioid utilization. Methods: In this prospective, double-blind study, 129 patients undergoing total knee arthroplasty were randomized to the QS or the MPPA group after skin incision. All surgical procedures utilized minimally invasive surgery principles and standardized anesthesia, implants, analgesia, and rehabilitation. The Knee Society Score (KSS) was obtained at baseline and one and three months after surgery. Weekly telephone interviews were used to collect patient-reported outcomes including ambulatory device use, the UCLA (University of California Los Angeles) activity score, performance of daily living activities, and opioid utilization. Results: No differences between groups were seen in opioid utilization, either during the acute hospitalization or in the eight weeks after surgery. The QS group reported significantly less pain at rest on postoperative day one and with activity on day three (p = 0.04 for each). Compared with baseline, both groups showed significant improvements in the KSS at one month (MPPA, p = 0.0278; QS, p = 0.0021) and three months (p < 0.0001 for each) as well as week-to-week gains in walking independence through five weeks after surgery. Independence from ambulatory devices outside the home lagged behind independence indoors by about two weeks in both groups. Conclusions: When primary total knee arthroplasty was performed with contemporary minimally invasive surgery principles and standardized implants, anesthesia, and postoperative pathways, the QS technique yielded no significant early functional advantages or differences in opioid utilization compared with the MPPA technique. However, the mean pain scores reported by patients in the QS group were slightly lower at rest on postoperative day one and during activity on day three. Level of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence. PMID:24897738

  6. Forced expiratory technique, directed cough, and autogenic drainage.

    PubMed

    Fink, James B

    2007-09-01

    In health, secretions produced in the respiratory tract are cleared by mucociliary transport, cephalad airflow bias, and cough. In disease, increased secretion viscosity and volume, dyskinesia of the cilia, and ineffective cough combine to reduce secretion clearance, leading to increased risk of infection. In obstructive lung disease these conditions are further complicated by early collapse of airways, due to airway compression, which traps both gas and secretions. Techniques have been developed to optimize expiratory flow and promote airway clearance. Directed cough, forced expiratory technique, active cycle of breathing, and autogenic drainage are all more effective than placebo and comparable in therapeutic effects to postural drainage; they require no special equipment or care-provider assistance for routine use. Researchers have suggested that standard chest physical therapy with active cycle of breathing and forced expiratory technique is more effective than chest physical therapy alone. Evidence-based reviews have suggested that, though successful adoption of techniques such as autogenic drainage may require greater control and training, patients with long-term secretion management problems should be taught as many of these techniques as they can master for adoption in their therapeutic routines.

  7. Marine Biological Field Techniques.

    ERIC Educational Resources Information Center

    Awkerman, Gary L.

    This publication is designed for use in a standard science curricula to develop oceanologic manifestations of certain science topics. Included are teacher guides, student activities, and demonstrations designed to impart ocean science understanding to high school students. It could be a useful instructional tool for any high school student field…

  8. Purification of pharmaceutical preparations using thin-layer chromatography to obtain mass spectra with Direct Analysis in Real Time and accurate mass spectrometry.

    PubMed

    Wood, Jessica L; Steiner, Robert R

    2011-06-01

    Forensic analysis of pharmaceutical preparations requires a comparative analysis with a standard of the suspected drug in order to identify the active ingredient. Purchasing analytical standards can be expensive or unattainable from the drug manufacturers. Direct Analysis in Real Time (DART™) is a novel, ambient ionization technique, typically coupled with a JEOL AccuTOF™ (accurate mass) mass spectrometer. While a fast and easy technique to perform, a drawback of using DART™ is the lack of component separation of mixtures prior to ionization. Various in-house pharmaceutical preparations were purified using thin-layer chromatography (TLC) and mass spectra were subsequently obtained using the AccuTOF™- DART™ technique. Utilizing TLC prior to sample introduction provides a simple, low-cost solution to acquiring mass spectra of the purified preparation. Each spectrum was compared against an in-house molecular formula list to confirm the accurate mass elemental compositions. Spectra of purified ingredients of known pharmaceuticals were added to an in-house library for use as comparators for casework samples. Resolving isomers from one another can be accomplished using collision-induced dissociation after ionization. Challenges arose when the pharmaceutical preparation required an optimized TLC solvent to achieve proper separation and purity of the standard. Purified spectra were obtained for 91 preparations and included in an in-house drug standard library. Primary standards would only need to be purchased when pharmaceutical preparations not previously encountered are submitted for comparative analysis. TLC prior to DART™ analysis demonstrates a time efficient and cost saving technique for the forensic drug analysis community. Copyright © 2011 John Wiley & Sons, Ltd. Copyright © 2011 John Wiley & Sons, Ltd.

  9. Activated carbon material

    DOEpatents

    Evans, A. Gary

    1978-01-01

    Activated carbon particles for use as iodine trapping material are impregnated with a mixture of selected iodine and potassium compounds to improve the iodine retention properties of the carbon. The I/K ratio is maintained at less than about 1 and the pH is maintained at above about 8.0. The iodine retention of activated carbon previously treated with or coimpregnated with triethylenediamine can also be improved by this technique. Suitable flame retardants can be added to raise the ignition temperature of the carbon to acceptable standards.

  10. Determination of the effective sample thickness via radiative capture

    DOE PAGES

    Hurst, A. M.; Summers, N. C.; Szentmiklosi, L.; ...

    2015-09-14

    Our procedure for determining the effective thickness of non-uniform irregular-shaped samples via radiative capture is described. In this technique, partial γ-ray production cross sections of a compound nucleus produced in a neutron-capture reaction are measured using Prompt Gamma Activation Analysis and compared to their corresponding standardized absolute values. For the low-energy transitions, the measured cross sections are lower than their standard values due to significant photoelectric absorption of the γ rays within the bulk-sample volume itself. Using standard theoretical techniques, the amount of γ-ray self absorption and neutron self shielding can then be calculated by iteratively varying the sample thicknessmore » until the observed cross sections converge with the known standards. The overall attenuation provides a measure of the effective sample thickness illuminated by the neutron beam. This procedure is illustrated through radiative neutron capture using powdered oxide samples comprising enriched 186W and 182W from which their tungsten-equivalent effective thicknesses are deduced to be 0.077(3) mm and 0.042(8) mm, respectively.« less

  11. Continuously active interferometer stabilization and control for time-bin entanglement distribution

    DOE PAGES

    Toliver, Paul; Dailey, James M.; Agarwal, Anjali; ...

    2015-02-10

    In this study, we describe a new method enabling continuous stabilization and fine-level phase control of time-bin entanglement interferometers. Using this technique we demonstrate entangled photon transmission through 50 km of standard single-mode fiber. This technique reuses the entangled-pair generation pump which is co-propagated with the transmitted entangled photons. In addition, the co-propagating pump adds minimal noise to the entangled photons which are characterized by measuring a two-photon interference fringe.

  12. Facile Site-Directed Mutagenesis of Large Constructs Using Gibson Isothermal DNA Assembly.

    PubMed

    Yonemoto, Isaac T; Weyman, Philip D

    2017-01-01

    Site-directed mutagenesis is a commonly used molecular biology technique to manipulate biological sequences, and is especially useful for studying sequence determinants of enzyme function or designing proteins with improved activity. We describe a strategy using Gibson Isothermal DNA Assembly to perform site-directed mutagenesis on large (>~20 kbp) constructs that are outside the effective range of standard techniques such as QuikChange II (Agilent Technologies), but more reliable than traditional cloning using restriction enzymes and ligation.

  13. Crystallographic Determination of Molecular Parameters for K2SiF6: A Physical Chemistry Laboratory Experiment.

    ERIC Educational Resources Information Center

    Loehlin, James H.; Norton, Alexandra P.

    1988-01-01

    Describes a crystallography experiment using both diffraction-angle and diffraction-intensity information to determine the lattice constant and a lattice independent molecular parameter, while still employing standard X-ray powder diffraction techniques. Details the method, experimental details, and analysis for this activity. (CW)

  14. Design for manufacturability production management activity report

    NASA Astrophysics Data System (ADS)

    Miyazaki, Norihiko; Sato, T.; Honma, M.; Yoshioka, N.; Hosono, K.; Onodera, T.; Itoh, H.; Suzuki, H.; Uga, T.; Kadota, K.; Iriki, N.

    2006-05-01

    Design For Manufacturability Production Management (DFM-PM) Subcommittee has been started in succession to Reticle Management Subcommittee (RMS) in Semiconductor Manufacturing Technology Committee for Japan (SMTCJ) from 2005. Our activity focuses on the SoC (System On Chip) Business, and it pursues the improvement of communication in manufacturing technique. The first theme of activity is the investigation and examination of the new trends about production (manufacturer) technology and related information, and proposals of business solution. The second theme is the standardization activity about manufacture technology and the cooperation with related semiconductors' organizations. And the third theme is holding workshop and support for promotion and spread of the standardization technology throughout semiconductor companies. We expand a range of scope from design technology to wafer pattern reliability and we will propose the competition domain, the collaboration area and the standardization technology on DFM. Furthermore, we will be able to make up a SoC business model as the 45nm node technology beyond manufacturing platform in cooperating with the design information and the production information by utilizing EDA technology.

  15. Studies on activated carbon derived from neem (azadirachta indica) bio-waste, and its application as supercapacitor electrode

    NASA Astrophysics Data System (ADS)

    Ahmed, Sultan; Parvaz, M.; Johari, Rahul; Rafat, M.

    2018-04-01

    The present study reports the preparation of quasi solid-state supercapacitor employing activated carbon (AC) electrodes and gel polymer electrolyte (GPE). AC was derived from Neem leaves by means of chemical activation using zinc chloride as activating agent. GPE was prepared using solution-cast technique and comprises of LiClO 4 salt, dispersed in EC:PC (1:1 vol.) and entrapped in PVdF-HFP solution. Extensive physical and electrochemical characterization of synthesized AC and GPE was done. AC was characterized using the techniques of SEM, TEM, XRD, Raman spectroscopy, TGA and BET tests while GPE was characterized by electrochemical stability window (ESW) and conductivity test. The fabricated supercapacitor cell was tested using standard electrochemical characterization techniques. It was found that the fabricated cell offers high values of specific capacitance (74.41 F g‑1), specific energy (10.33 Wh kg‑1) and specific power (4.66 kW kg‑1). These results demonstrate the suitability of prepared AC as promising electrode material for supercapacitor applications.

  16. Improved ultrasonic standard reference blocks

    NASA Technical Reports Server (NTRS)

    Eitzen, D. G.; Sushinsky, G. F.; Chwirut, D. J.; Bechtoldt, C. J.; Ruff, A. W.

    1976-01-01

    A program to improve the quality, reproducibility and reliability of nondestructive testing through the development of improved ASTM-type ultrasonic reference standards is described. Reference blocks of aluminum, steel, and titanium alloys are to be considered. Equipment representing the state-of-the-art in laboratory and field ultrasonic equipment was obtained and evaluated. RF and spectral data on ten sets of ultrasonic reference blocks have been taken as part of a task to quantify the variability in response from nominally identical blocks. Techniques for residual stress, preferred orientation, and micro-structural measurements were refined and are applied to a reference block rejected by the manufacturer during fabrication in order to evaluate the effect of metallurgical condition on block response. New fabrication techniques for reference blocks are discussed and ASTM activities are summarized.

  17. Biologic Approaches for the Treatment of Partial Tears of the Anterior Cruciate Ligament

    PubMed Central

    Dallo, Ignacio; Chahla, Jorge; Mitchell, Justin J.; Pascual-Garrido, Cecilia; Feagin, John A.; LaPrade, Robert F.

    2017-01-01

    Background: Anterior cruciate ligament reconstruction (ACLR) has been established as the gold standard for treatment of complete ruptures of the anterior cruciate ligament (ACL) in active, symptomatic individuals. In contrast, treatment of partial tears of the ACL remains controversial. Biologically augmented ACL-repair techniques are expanding in an attempt to regenerate and improve healing and outcomes of both the native ACL and the reconstructed graft tissue. Purpose: To review the biologic treatment options for partial tears of the ACL. Study Design: Review. Methods: A literature review was performed that included searches of PubMed, Medline, and Cochrane databases using the following keywords: partial tear of the ACL, ACL repair, bone marrow concentrate, growth factors/healing enhancement, platelet-rich plasma (PRP), stem cell therapy. Results: The use of novel biologic ACL repair techniques, including growth factors, PRP, stem cells, and bioscaffolds, have been reported to result in promising preclinical and short-term clinical outcomes. Conclusion: The potential benefits of these biological augmentation approaches for partial ACL tears are improved healing, better proprioception, and a faster return to sport and activities of daily living when compared with standard reconstruction procedures. However, long-term studies with larger cohorts of patients and with technique validation are necessary to assess the real effect of these approaches. PMID:28210653

  18. Detection of cortical optical changes during seizure activity using optical coherence tomography (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Ornelas, Danielle; Hasan, Md.; Gonzalez, Oscar; Krishnan, Giri; Szu, Jenny I.; Myers, Timothy; Hirota, Koji; Bazhenov, Maxim; Binder, Devin K.; Park, Boris H.

    2017-02-01

    Electrophysiology has remained the gold standard of neural activity detection but its resolution and high susceptibility to noise and motion artifact limit its efficiency. Imaging techniques, including fMRI, intrinsic optical imaging, and diffuse optical imaging, have been used to detect neural activity, but rely on indirect measurements such as changes in blood flow. Fluorescence-based techniques, including genetically encoded indicators, are powerful techniques, but require introduction of an exogenous fluorophore. A more direct optical imaging technique is optical coherence tomography (OCT), a label-free, high resolution, and minimally invasive imaging technique that can produce depth-resolved cross-sectional and 3D images. In this study, we sought to examine non-vascular depth-dependent optical changes directly related to neural activity. We used an OCT system centered at 1310 nm to search for changes in an ex vivo brain slice preparation and an in vivo model during 4-AP induced seizure onset and propagation with respect to electrical recording. By utilizing Doppler OCT and the depth-dependency of the attenuation coefficient, we demonstrate the ability to locate and remove the optical effects of vasculature within the upper regions of the cortex from in vivo attenuation calculations. The results of this study show a non-vascular decrease in intensity and attenuation in ex vivo and in vivo seizure models, respectively. Regions exhibiting decreased optical changes show significant temporal correlation to regions of increased electrical activity during seizure. This study allows for a thorough and biologically relevant analysis of the optical signature of seizure activity both ex vivo and in vivo using OCT.

  19. External trial deep brain stimulation device for the application of desynchronizing stimulation techniques.

    PubMed

    Hauptmann, C; Roulet, J-C; Niederhauser, J J; Döll, W; Kirlangic, M E; Lysyansky, B; Krachkovskyi, V; Bhatti, M A; Barnikol, U B; Sasse, L; Bührle, C P; Speckmann, E-J; Götz, M; Sturm, V; Freund, H-J; Schnell, U; Tass, P A

    2009-12-01

    In the past decade deep brain stimulation (DBS)-the application of electrical stimulation to specific target structures via implanted depth electrodes-has become the standard treatment for medically refractory Parkinson's disease and essential tremor. These diseases are characterized by pathological synchronized neuronal activity in particular brain areas. We present an external trial DBS device capable of administering effectively desynchronizing stimulation techniques developed with methods from nonlinear dynamics and statistical physics according to a model-based approach. These techniques exploit either stochastic phase resetting principles or complex delayed-feedback mechanisms. We explain how these methods are implemented into a safe and user-friendly device.

  20. Report of the panel on international programs

    NASA Technical Reports Server (NTRS)

    Anderson, Allen Joel; Fuchs, Karl W.; Ganeka, Yasuhiro; Gaur, Vinod; Green, Andrew A.; Siegfried, W.; Lambert, Anthony; Rais, Jacub; Reighber, Christopher; Seeger, Herman

    1991-01-01

    The panel recommends that NASA participate and take an active role in the continuous monitoring of existing regional networks, the realization of high resolution geopotential and topographic missions, the establishment of interconnection of the reference frames as defined by different space techniques, the development and implementation of automation for all ground-to-space observing systems, calibration and validation experiments for measuring techniques and data, the establishment of international space-based networks for real-time transmission of high density space data in standardized formats, tracking and support for non-NASA missions, and the extension of state-of-the art observing and analysis techniques to developing nations.

  1. Standardized pivot shift test improves measurement accuracy.

    PubMed

    Hoshino, Yuichi; Araujo, Paulo; Ahlden, Mattias; Moore, Charity G; Kuroda, Ryosuke; Zaffagnini, Stefano; Karlsson, Jon; Fu, Freddie H; Musahl, Volker

    2012-04-01

    The variability of the pivot shift test techniques greatly interferes with achieving a quantitative and generally comparable measurement. The purpose of this study was to compare the variation of the quantitative pivot shift measurements with different surgeons' preferred techniques to a standardized technique. The hypothesis was that standardizing the pivot shift test would improve consistency in the quantitative evaluation when compared with surgeon-specific techniques. A whole lower body cadaveric specimen was prepared to have a low-grade pivot shift on one side and high-grade pivot shift on the other side. Twelve expert surgeons performed the pivot shift test using (1) their preferred technique and (2) a standardized technique. Electromagnetic tracking was utilized to measure anterior tibial translation and acceleration of the reduction during the pivot shift test. The variation of the measurement was compared between the surgeons' preferred technique and the standardized technique. The anterior tibial translation during pivot shift test was similar between using surgeons' preferred technique (left 24.0 ± 4.3 mm; right 15.5 ± 3.8 mm) and using standardized technique (left 25.1 ± 3.2 mm; right 15.6 ± 4.0 mm; n.s.). However, the variation in acceleration was significantly smaller with the standardized technique (left 3.0 ± 1.3 mm/s(2); right 2.5 ± 0.7 mm/s(2)) compared with the surgeons' preferred technique (left 4.3 ± 3.3 mm/s(2); right 3.4 ± 2.3 mm/s(2); both P < 0.01). Standardizing the pivot shift test maneuver provides a more consistent quantitative evaluation and may be helpful in designing future multicenter clinical outcome trials. Diagnostic study, Level I.

  2. [Effectively communicate active listening : Comparison of two concepts].

    PubMed

    Martin, O; Rockenbauch, K; Kleinert, E; Stöbel-Richter, Y

    2017-09-01

    Communication between physicians and patients has a great influence on patient adherence, patient satisfaction and the success of treatment. In this context, patient centered care and emotional support have a high positive impact; however, it is unclear how physicians can be motivated to communicate with patients in an appreciative and empathetic way. The implementation of such behavior requires a multitude of communicative skills. One of them is active listening, which is very important in two respects. On the one hand active listening provides the basis for several conversational contexts as a special communication technique and on the other hand active listening is presented in current textbooks in different ways: as an attitude or as a technique. In light of this, the question arises how active listening should be taught in order to be not only applicable in concrete conversations but also to lead to the highest possible level of patient satisfaction. The aim of this pilot study was to examine some variations in simulated doctor-patient conversations, which are the result of the different approaches to active listening. For this purpose three groups of first semester medical students were recruited, two of which were schooled in active listening in different ways (two groups of six students), i.e. attitude versus technique oriented. The third group (seven students) acted as the control group. In a pre-post design interviews with standardized simulation patients were conducted and subsequently evaluated. The analysis of these interviews was considered from the perspectives of participants and observers as well as the quantitative aspects. This study revealed some interesting tendencies despite its status as a pilot study: in general, the two interventional groups performed significantly better than the control group in which no relevant changes occurred. In a direct comparison, the group in which active listening was taught from an attitude approach achieved better results than the group in which the focus was on the technical aspects of active listening. In the group with active listening schooled as an attitude, the response to the feelings of the standardized simulation patients was significantly better from the perspectives of both participants and observers.

  3. [Single-port laparoscopic cholecystectomy: advantages and disadvantages].

    PubMed

    Alekberzade, A V; Lipnitsky, E M; Krylov, N N; Sundukov, I V; Badalov, D A

    2016-01-01

    To analyze the outcomes of single-port laparoscopic cholecystectomy. Early and long-term postoperative period has been analyzed in 240 patients who underwent laparoscopic cholecystectomy (LCE) including 120 cases of single-port technique and 120 cases of four-port technique. Both groups were compared in surgical time, pain syndrome severity (visual analog scale), need for analgesics, postoperative complications, hospital-stay, daily activity recovery and return to physical work, patients' satisfaction of surgical results and their aesthetic effect. It was revealed that single-port LCE is associated with lower severity of postoperative pain, quick recovery of daily activity and return to physical work, high satisfaction of surgical results and their aesthetic effect compared with four-port LCE. Disadvantages of single-port LCE include longer duration of surgery, high incidence of postoperative umbilical hernia. However hernia was predominantly observed during the period of surgical technique development. Further studies to standardize, evaluate the safety and benefits of single-port LCE are necessary.

  4. The temporal outcomes of open versus arthroscopic knotted and knotless rotator cuff repair over 5 years

    PubMed Central

    Lucena, Thomas R; Lam, Patrick H; Millar, Neal L

    2015-01-01

    Background The present study aimed to determine how repair technique influenced structural and clinical outcomes at 5 years post-surgery. Methods Three cohorts of patients had repair of a symptomatic rotator cuff tear using (i) an open double-row mattress repair technique (n = 25); (ii) arthroscopic single-row simple suture knotted technique (n = 25); or (iii) arthroscopic single-row inverted mattress knotless technique (n = 36) by one surgeon. Standardized patient- and examiner-determined outcomes were obtained pre-operatively and postoperatively with a validated protocol, ultrasound were also performed at the same time. Results Retear occurred more often after open repair (48%) at 5 years than after arthroscopic knotted (33%) and arthroscopic knotless (26%) repair. Retear was associated with increasing age, pre-operative tear size and weaker pre-operative and 5 years postoperative cuff strength. Between 2 years and 5 years, the open repair group experienced an increase in the frequency of pain during activity, as well as in the difficulty experienced and the severity of pain during overhead activities (p < 0.05) and, at 5 years, also experienced more difficulty with overhead activities, compared to the arthroscopic knotless repair group. Conclusions At 5-year follow-up, arthroscopic rotator cuff repair techniques resulted in fewer retears and better outcomes compared to an open double-row technique. PMID:27582985

  5. Conventional and microwave assisted synthesis of pyrazolone Mannich bases possessing anti-inflammatory, analgesic, ulcerogenic effect and antimicrobial properties.

    PubMed

    Sivakumar, Kullampalayam Krishnasamy; Rajasekaran, Aiyalu; Senthilkumar, Palaniappan; Wattamwar, Prasad P

    2014-07-01

    In the present study, an efficient synthesis of some Mannich base of 5-methyl-2-[(2-oxo-2H-chromen-3-yl)carbonyl]-2,4-dihydro-3H-pyrazol-3-one (4a-j) have been described by using conventional and non-conventional (microwave) techniques. Microwave assisted reactions showed that require shorter reaction time and good yield. The newly synthesized compounds were screened for their anti-inflammatory, analgesic activity, antioxidant, and antibacterial effects were compared with standard drug. Among the compounds studied, compound (4f) showing nearly equipotent anti-inflammatory and analgesic activity than the standard drug (indomethacin), along with minimum ulcerogenic index. Compounds (4b and 4i) showing 1.06 times more active than ciprofloxacin against tested Gram-negative bacteria. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Comparison of a new noncoplanar intensity-modulated radiation therapy technique for craniospinal irradiation with 3 coplanar techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hansen, Anders T., E-mail: andehans@rm.dk; Lukacova, Slavka; Lassen-Ramshad, Yasmin

    2015-01-01

    When standard conformal x-ray technique for craniospinal irradiation is used, it is a challenge to achieve satisfactory dose coverage of the target including the area of the cribriform plate, while sparing organs at risk. We present a new intensity-modulated radiation therapy (IMRT), noncoplanar technique, for delivering irradiation to the cranial part and compare it with 3 other techniques and previously published results. A total of 13 patients who had previously received craniospinal irradiation with standard conformal x-ray technique were reviewed. New treatment plans were generated for each patient using the noncoplanar IMRT-based technique, a coplanar IMRT-based technique, and a coplanarmore » volumetric-modulated arch therapy (VMAT) technique. Dosimetry data for all patients were compared with the corresponding data from the conventional treatment plans. The new noncoplanar IMRT technique substantially reduced the mean dose to organs at risk compared with the standard radiation technique. The 2 other coplanar techniques also reduced the mean dose to some of the critical organs. However, this reduction was not as substantial as the reduction obtained by the noncoplanar technique. Furthermore, compared with the standard technique, the IMRT techniques reduced the total calculated radiation dose that was delivered to the normal tissue, whereas the VMAT technique increased this dose. Additionally, the coverage of the target was significantly improved by the noncoplanar IMRT technique. Compared with the standard technique, the coplanar IMRT and the VMAT technique did not improve the coverage of the target significantly. All the new planning techniques increased the number of monitor units (MU) used—the noncoplanar IMRT technique by 99%, the coplanar IMRT technique by 122%, and the VMAT technique by 26%—causing concern for leak radiation. The noncoplanar IMRT technique covered the target better and decreased doses to organs at risk compared with the other techniques. All the new techniques increased the number of MU compared with the standard technique.« less

  7. Quality improvement prototype: Johnson Space Center, National Aeronautics and Space Administration

    NASA Technical Reports Server (NTRS)

    1990-01-01

    The Johnson Space Flight Center was recognized by the Office of Management and Budget as a model for its high standards of quality. Included are an executive summary of the center's activities, an organizational overview, techniques for improving quality, the status of the quality effort and a listing of key personnel.

  8. Favorite Labs from Outstanding Teachers. Monograph VII.

    ERIC Educational Resources Information Center

    Sheldon, Daniel S., Ed.; Penick, John E., Ed.

    This monograph is the first attempt to collect and share some of the teaching techniques, activities, and ideas of former recipients of the Outstanding Biology Teacher Award. The lessons are organized into topical themes to facilitate their incorporation into standard curriculum. The manual is divided into two main sections, "Labs" and "Ideas."…

  9. A Research-Inspired Laboratory Sequence Investigating Acquired Drug Resistance

    ERIC Educational Resources Information Center

    Taylor, Elizabeth Vogel; Fortune, Jennifer A.; Drennan, Catherine L.

    2010-01-01

    Here, we present a six-session laboratory exercise designed to introduce students to standard biochemical techniques in the context of investigating a high impact research topic, acquired resistance to the cancer drug Gleevec. Students express a Gleevec-resistant mutant of the Abelson tyrosine kinase domain, the active domain of an oncogenic…

  10. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR ANALYSIS OF ACTIVE VOC SAMPLES (BCO-L-19.0)

    EPA Science Inventory

    This abstract is included for completeness of documentation. The technique described in the SOP title was planned in writing the QSIP. It was subsequently not used, and the SOP was not written.

    The National Human Exposure Assessment Survey (NHEXAS) is a federal interagency r...

  11. 7 CFR 650.21 - Working relations with the U.S. Environmental Protection Agency (EPA) and related State...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... standards. (iii) Consider EPA needs in soil survey and land, inventory, and monitoring activities. (iv... EIS's. (v) Advise EPA regarding soils, plant materials, and soil and water conservation techniques..., transport of pesticides, organic matter and fertilizers, and burning of residues or clearing debris. (2) The...

  12. 7 CFR 650.21 - Working relations with the U.S. Environmental Protection Agency (EPA) and related State...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... standards. (iii) Consider EPA needs in soil survey and land, inventory, and monitoring activities. (iv... EIS's. (v) Advise EPA regarding soils, plant materials, and soil and water conservation techniques..., transport of pesticides, organic matter and fertilizers, and burning of residues or clearing debris. (2) The...

  13. 7 CFR 650.21 - Working relations with the U.S. Environmental Protection Agency (EPA) and related State...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... standards. (iii) Consider EPA needs in soil survey and land, inventory, and monitoring activities. (iv... EIS's. (v) Advise EPA regarding soils, plant materials, and soil and water conservation techniques..., transport of pesticides, organic matter and fertilizers, and burning of residues or clearing debris. (2) The...

  14. 7 CFR 650.21 - Working relations with the U.S. Environmental Protection Agency (EPA) and related State...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... standards. (iii) Consider EPA needs in soil survey and land, inventory, and monitoring activities. (iv... EIS's. (v) Advise EPA regarding soils, plant materials, and soil and water conservation techniques..., transport of pesticides, organic matter and fertilizers, and burning of residues or clearing debris. (2) The...

  15. 7 CFR 650.21 - Working relations with the U.S. Environmental Protection Agency (EPA) and related State...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... standards. (iii) Consider EPA needs in soil survey and land, inventory, and monitoring activities. (iv... EIS's. (v) Advise EPA regarding soils, plant materials, and soil and water conservation techniques..., transport of pesticides, organic matter and fertilizers, and burning of residues or clearing debris. (2) The...

  16. Analysis of He I 1083 nm Imaging Spectroscopy Using a Spectral Standard

    NASA Technical Reports Server (NTRS)

    Malanushenko, Elena V.; Jones, Harrison P.

    2004-01-01

    We develop a technique. for the analysis of He I 1083 nanometer spectra which addresses several difficulties through determination of a continuum background by comparison with a well calibrated standard and through removal of nearby solar and telluric blends by differential comparison to an average spectrum. The method is compared with earlier analysis of imaging spectroscopy obtained at the National Solar Observatory/Kitt Peak Vacuum Telescope (NSO/KPVT) with the NASA/NSO Spectromagnetograph (SPM). We examine distributions of Doppler velocity and line width as a function of central intensity for an active region, filament, quiet Sun, and coronal hole. For our example, we find that line widths and central intensity are oppositely correlated in a coronal hole and quiet Sun. Line widths are comparable to the quiet sun in the active region, are systematically lower in the filament, and extend to higher values in the coronal hole. Outward velocities of approximately equal to 2 to 4 kilometers per second are typically observed in the coronal hole. The sensitivity of these results to analysis technique is discussed.

  17. Value of diffusion-weighted imaging when added to magnetic resonance enterographic evaluation of Crohn disease in children.

    PubMed

    Shenoy-Bhangle, Anuradha S; Nimkin, Katherine; Aranson, Thomas; Gee, Michael S

    2016-01-01

    MR enterography is increasingly utilized for noninvasive evaluation of disease activity in young patients with Crohn disease and has great impact on clinical management. Diffusion-weighted imaging (DWI) is a rapid MR imaging technique that measures molecular diffusion of water and is sensitive to the inflammatory process; however, its value to MR enterography has not been rigorously evaluated. To determine whether the addition of DWI to MR enterography is helpful in evaluating Crohn disease activity in young patients when compared to a histological reference. In this single-institution retrospective study, we searched an imaging database for the period January 2010 to December 2012 to identify patients age 19 years and younger who had MR enterography with diffusion-weighted imaging (DWI). We used an electronic medical record search to identify those who had MR enterography and colonoscopy performed within 28 days of each other. All MR enterography scans were performed on a 1.5-T or 3-T clinical MR scanner with phased-array torso coil configuration using standard pulse sequences as well as axial DWI with b values of 50, 400 and 800. Bowel segments were evaluated for disease activity based on standard MR enterography sequences; in addition, segmental apparent diffusion coefficient (ADC) values were calculated based on DWI. Histological reference for disease activity was based on assessment for mucosal inflammatory changes on endoscopic biopsy. MR enterography and DWI evaluation were performed in a blinded fashion with respect to histological results. We included imaging of 78 bowel segments from 27 patients (mean age 14.5 ± 3.02 years) with known Crohn disease in the study. The mean ADC for bowel segments with active disease was 1.56 ± 0.7 × 10(3) mm(2)/s compared with 2.58 ± 1.4 × 10(3) mm(2)/s for segments without active disease, a difference that was statistically significant (P < 0.01, Student's t-test). Using a threshold value of 2.0 × 10(3) mm(2)/s, DWI demonstrated lower accuracy (64.1%) but higher sensitivity (78.8%) for detecting active disease compared with standard MR enterography (69.2% and 54.6%, respectively). Combining DWI with MR enterography, using DWI as the initial screen and MR enterography afterward to reduce false negativity, led to a significant increase in accuracy (76.9%; P = 0.03, McNemar's test) compared with either imaging technique alone. Although DWI does not perform as well as standard MR enterography for detection of active Crohn disease, the combination of DWI and MR enterography increases imaging accuracy for determining disease activity compared with either technique alone. These results indicate that DWI adds value to MR enterography and supports the incorporation of DWI into MR enterography protocols for evaluation of Crohn disease in young patients.

  18. Comparison of Preloaded Bougie versus Standard Bougie Technique for Endotracheal Intubation in a Cadaveric Model.

    PubMed

    Baker, Jay B; Maskell, Kevin F; Matlock, Aaron G; Walsh, Ryan M; Skinner, Carl G

    2015-07-01

    We compared intubating with a preloaded bougie (PB) against standard bougie technique in terms of success rates, time to successful intubation and provider preference on a cadaveric airway model. In this prospective, crossover study, healthcare providers intubated a cadaver using the PB technique and the standard bougie technique. Participants were randomly assigned to start with either technique. Following standardized training and practice, procedural success and time for each technique was recorded for each participant. Subsequently, participants were asked to rate their perceived ease of intubation on a visual analogue scale of 1 to 10 (1=difficult and 10=easy) and to select which technique they preferred. 47 participants with variable experience intubating were enrolled at an emergency medicine intern airway course. The success rate of all groups for both techniques was equal (95.7%). The range of times to completion for the standard bougie technique was 16.0-70.2 seconds, with a mean time of 29.7 seconds. The range of times to completion for the PB technique was 15.7-110.9 seconds, with a mean time of 29.4 seconds. There was a non-significant difference of 0.3 seconds (95% confidence interval -2.8 to 3.4 seconds) between the two techniques. Participants rated the relative ease of intubation as 7.3/10 for the standard technique and 7.6/10 for the preloaded technique (p=0.53, 95% confidence interval of the difference -0.97 to 0.50). Thirty of 47 participants subjectively preferred the PB technique (p=0.039). There was no significant difference in success or time to intubation between standard bougie and PB techniques. The majority of participants in this study preferred the PB technique. Until a clear and clinically significant difference is found between these techniques, emergency airway operators should feel confident in using the technique with which they are most comfortable.

  19. Evaluated activation cross sections of longer-lived radionuclides produced by deuteron induced reactions on natural nickel

    NASA Astrophysics Data System (ADS)

    Takács, S.; Tárkányi, F.; Király, B.; Hermanne, A.; Sonck, M.

    2007-07-01

    Activation cross sections for deuteron induced nuclear reactions on natural nickel target were studied by using a standard stacked foil technique and gamma spectrometry up to 50 MeV deuteron bombarding energy. Reaction products with half life of at least half an hour were studied. Experimental elemental activation cross sections were determined for reactions on nickel resulting in 61,64Cu, 56,57Ni, 55,56,57,58,60,61Co, 52,54,56Mn and 51Cr radionuclides and were compared with earlier measured data.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bowman, Adam J.; Scherrer, Joseph R.; Reiserer, Ronald S., E-mail: ron.reiserer@vanderbilt.edu

    We present a simple apparatus for improved surface modification of polydimethylsiloxane (PDMS) microfluidic devices. A single treatment chamber for plasma activation and chemical/physical vapor deposition steps minimizes the time-dependent degradation of surface activation that is inherent in multi-chamber techniques. Contamination and deposition irregularities are also minimized by conducting plasma activation and treatment phases in the same vacuum environment. An inductively coupled plasma driver allows for interchangeable treatment chambers. Atomic force microscopy confirms that silane deposition on PDMS gives much better surface quality than standard deposition methods, which yield a higher local roughness and pronounced irregularities in the surface.

  1. Photocatalytic degradation of textile dye using TiO2-activated carbon nanocomposite

    NASA Astrophysics Data System (ADS)

    Ghosh, Gourab; Basu, Sankhadeep; Saha, Sudeshna

    2018-05-01

    Rapid industrialisation has extended the use of dyes in various industrial applications in order to meet the escalating demands on consumer products. The toxicity level of a particular dye is very important due to its diverse effects on the environment and living organisms. Among all the techniques for dye removal, adsorption and photocatalysis are two important processes which are gaining much attention in recent years. In the present study activated carbon (adsorbent), TiO2 nanoparticles (photocatalyst) and their composite were used for dye removal. Prepared samples were characterized using standard characterization techniques such as XRD and SEM. Activated carbon was prepared from waste shells of Sterculia foetida. Mixture of activated carbon (activation temperature 600°C) and titania (calcined at 500°C) in the ratio 1:1 displayed greater dye removal efficiency than its individual components. Reusability study indicated that the mixture could effectively be used without further regeneration as very little loss in efficiency was observed after single cycle use.

  2. Evaluated activation cross sections of longer-lived radionuclides produced by deuteron-induced reactions on natural copper

    NASA Astrophysics Data System (ADS)

    Takács, S.; Tárkányi, F.; Király, B.; Hermanne, A.; Sonck, M.

    2006-09-01

    Activation cross sections for deuteron-induced reactions on natural copper were measured by using a standard stacked foil technique up to 50 MeV deuteron bombarding energy. Reaction products with half-life longer than half an hour were studied. Experimental elemental cross sections were determined and compared with earlier measured data for 62,63,65Zn, 64Cu, 57,65Ni, 57,58,60Co and 59Fe isotopes.

  3. Behavior Change Techniques Implemented in Electronic Lifestyle Activity Monitors: A Systematic Content Analysis

    PubMed Central

    Lewis, Zakkoyya H; Mayrsohn, Brian G; Rowland, Jennifer L

    2014-01-01

    Background Electronic activity monitors (such as those manufactured by Fitbit, Jawbone, and Nike) improve on standard pedometers by providing automated feedback and interactive behavior change tools via mobile device or personal computer. These monitors are commercially popular and show promise for use in public health interventions. However, little is known about the content of their feedback applications and how individual monitors may differ from one another. Objective The purpose of this study was to describe the behavior change techniques implemented in commercially available electronic activity monitors. Methods Electronic activity monitors (N=13) were systematically identified and tested by 3 trained coders for at least 1 week each. All monitors measured lifestyle physical activity and provided feedback via an app (computer or mobile). Coding was based on a hierarchical list of 93 behavior change techniques. Further coding of potentially effective techniques and adherence to theory-based recommendations were based on findings from meta-analyses and meta-regressions in the research literature. Results All monitors provided tools for self-monitoring, feedback, and environmental change by definition. The next most prevalent techniques (13 out of 13 monitors) were goal-setting and emphasizing discrepancy between current and goal behavior. Review of behavioral goals, social support, social comparison, prompts/cues, rewards, and a focus on past success were found in more than half of the systems. The monitors included a range of 5-10 of 14 total techniques identified from the research literature as potentially effective. Most of the monitors included goal-setting, self-monitoring, and feedback content that closely matched recommendations from social cognitive theory. Conclusions Electronic activity monitors contain a wide range of behavior change techniques typically used in clinical behavioral interventions. Thus, the monitors may represent a medium by which these interventions could be translated for widespread use. This technology has broad applications for use in clinical, public health, and rehabilitation settings. PMID:25131661

  4. Behavior change techniques implemented in electronic lifestyle activity monitors: a systematic content analysis.

    PubMed

    Lyons, Elizabeth J; Lewis, Zakkoyya H; Mayrsohn, Brian G; Rowland, Jennifer L

    2014-08-15

    Electronic activity monitors (such as those manufactured by Fitbit, Jawbone, and Nike) improve on standard pedometers by providing automated feedback and interactive behavior change tools via mobile device or personal computer. These monitors are commercially popular and show promise for use in public health interventions. However, little is known about the content of their feedback applications and how individual monitors may differ from one another. The purpose of this study was to describe the behavior change techniques implemented in commercially available electronic activity monitors. Electronic activity monitors (N=13) were systematically identified and tested by 3 trained coders for at least 1 week each. All monitors measured lifestyle physical activity and provided feedback via an app (computer or mobile). Coding was based on a hierarchical list of 93 behavior change techniques. Further coding of potentially effective techniques and adherence to theory-based recommendations were based on findings from meta-analyses and meta-regressions in the research literature. All monitors provided tools for self-monitoring, feedback, and environmental change by definition. The next most prevalent techniques (13 out of 13 monitors) were goal-setting and emphasizing discrepancy between current and goal behavior. Review of behavioral goals, social support, social comparison, prompts/cues, rewards, and a focus on past success were found in more than half of the systems. The monitors included a range of 5-10 of 14 total techniques identified from the research literature as potentially effective. Most of the monitors included goal-setting, self-monitoring, and feedback content that closely matched recommendations from social cognitive theory. Electronic activity monitors contain a wide range of behavior change techniques typically used in clinical behavioral interventions. Thus, the monitors may represent a medium by which these interventions could be translated for widespread use. This technology has broad applications for use in clinical, public health, and rehabilitation settings.

  5. γγ coincidence spectrometer for instrumental neutron-activation analysis

    NASA Astrophysics Data System (ADS)

    Tomlin, B. E.; Zeisler, R.; Lindstrom, R. M.

    2008-05-01

    Neutron-activation analysis (NAA) is an important technique for the accurate and precise determination of trace and ultra-trace elemental compositions. The application of γγ coincidence counting to NAA in order to enhance specificity was first explored over 40 years ago but has not evolved into a regularly used technique. A γγ coincidence spectrometer has been constructed at the National Institute of Standards and Technology, using two HPGe γ-ray detectors and an all-digital data-acquisition system, for the purpose of exploring coincidence NAA and its value in characterizing reference materials. This paper describes the initial evaluation of the quantitative precision of coincidence counting versus singles spectrometry, based upon a sample of neutron-irradiated bovine liver material.

  6. Associating clinical archetypes through UMLS Metathesaurus term clusters.

    PubMed

    Lezcano, Leonardo; Sánchez-Alonso, Salvador; Sicilia, Miguel-Angel

    2012-06-01

    Clinical archetypes are modular definitions of clinical data, expressed using standard or open constraint-based data models as the CEN EN13606 and openEHR. There is an increasing archetype specification activity that raises the need for techniques to associate archetypes to support better management and user navigation in archetype repositories. This paper reports on a computational technique to generate tentative archetype associations by mapping them through term clusters obtained from the UMLS Metathesaurus. The terms are used to build a bipartite graph model and graph connectivity measures can be used for deriving associations.

  7. Whole body MRI, including diffusion-weighted imaging in follow-up of patients with testicular cancer.

    PubMed

    Mosavi, Firas; Laurell, Anna; Ahlström, Håkan

    2015-11-01

    Whole body (WB) magnetic resonance imaging (MRI), including diffusion-weighted imaging (DWI) has become increasingly utilized in cancer imaging, yet the clinical utility of these techniques in follow-up of testicular cancer patients has not been evaluated. The purpose of this study was to evaluate the feasibility of WB MRI with continuous table movement (CTM) technique, including multistep DWI in follow-up of patients with testicular cancer. WB MRI including DWI was performed in follow-up of 71 consecutive patients (median age, 37 years; range 19-84) with histologically confirmed testicular cancer. WB MRI protocol included axial T1-Dixon and T2-BLADE sequences using CTM technique. Furthermore, multi-step DWI was performed using b-value 50 and 1000 s/mm(2). One criterion for feasibility was patient tolerance and satisfactory image quality. Another criterion was the accuracy in detection of any pathological mass, compared to standard of reference. Signal intensity in DWI was used for evaluation of residual mass activity. Clinical, laboratory and imaging follow-up were applied as standard of reference for the evaluation of WB MRI. WB MRI was tolerated in nearly all patients (69/71 patients, 97%) and the image quality was satisfactory. Metal artifacts deteriorated the image quality in six patients, but it did not influence the overall results. No case of clinical relapse was observed during the follow-up time. There was a good agreement between conventional WB MRI and standard of reference in all patients. Three patients showed residual masses and DWI signal was not restricted in these patients. Furthermore, DWI showed abnormally high signal intensity in a normal-sized retroperitoneal lymph node indicating metastasis. The subsequent (18)F-FDG PET/CT could verify the finding. WB MRI with CTM technique including multi-step DWI is feasible in follow-up of patients with testicular cancer. DWI may contribute to important added-value data to conventional MRI sequences regarding the activity of residual masses.

  8. The MCART radiation physics core: the quest for radiation dosimetry standardization.

    PubMed

    Kazi, Abdul M; MacVittie, Thomas J; Lasio, Giovanni; Lu, Wei; Prado, Karl L

    2014-01-01

    Dose-related radiobiological research results can only be compared meaningfully when radiation dosimetry is standardized. To this purpose, the National Institute of Allergy and Infectious Diseases (NIAID)-sponsored Medical Countermeasures Against Radiological Threats (MCART) consortium recently created a Radiation Physics Core (RPC) as an entity to assume responsibility of standardizing radiation dosimetry practices among its member laboratories. The animal research activities in these laboratories use a variety of ionizing photon beams from several irradiators such as 250-320 kVp x-ray generators, Cs irradiators, Co teletherapy machines, and medical linear accelerators (LINACs). In addition to this variety of sources, these centers use a range of irradiation techniques and make use of different dose calculation schemes to conduct their experiments. An extremely important objective in these research activities is to obtain a Dose Response Relationship (DRR) appropriate to their respective organ-specific models of acute and delayed radiation effects. A clear and unambiguous definition of the DRR is essential for the development of medical countermeasures. It is imperative that these DRRs are transparent between centers. The MCART RPC has initiated the establishment of standard dosimetry practices among member centers and is introducing a Remote Dosimetry Monitoring Service (RDMS) to ascertain ongoing quality assurance. This paper will describe the initial activities of the MCART RPC toward implementing these standardization goals. It is appropriate to report a summary of initial activities with the intent of reporting the full implementation at a later date.

  9. Parametric and Generative Design Techniques for Digitalization in Building Industry: the Case Study of Glued- Laminated-Timber Industry

    NASA Astrophysics Data System (ADS)

    Pasetti Monizza, G.; Matt, D. T.; Benedetti, C.

    2016-11-01

    According to Wortmann classification, the Building Industry (BI) can be defined as engineer-to-order (ETO) industry: the engineering-process starts only when an order is acquired. This definition implies that every final product (building) is almost unique’ and processes cannot be easily standardized or automated. Because of this, BI is one of the less efficient industries today’ mostly leaded by craftsmanship. In the last years’ several improvements in process efficiency have been made focusing on manufacturing and installation processes only. In order to improve the efficiency of design and engineering processes as well, the scientific community agrees that the most fruitful strategy should be Front-End Design (FED). Nevertheless, effective techniques and tools are missing. This paper discusses outcomes of a research activity that aims at highlighting whether Parametric and Generative Design techniques allow reducing wastes of resources and improving the overall efficiency of the BI, by pushing the Digitalization of design and engineering processes of products. Focusing on the Glued-Laminated-Timber industry, authors will show how Parametric and Generative Design techniques can be introduced in a standard supply-chain system, highlighting potentials and criticism on the supply-chain system as a whole.

  10. Neuroimaging techniques for memory detection: scientific, ethical, and legal issues.

    PubMed

    Meegan, Daniel V

    2008-01-01

    There is considerable interest in the use of neuroimaging techniques for forensic purposes. Memory detection techniques, including the well-publicized Brain Fingerprinting technique (Brain Fingerprinting Laboratories, Inc., Seattle WA), exploit the fact that the brain responds differently to sensory stimuli to which it has been exposed before. When a stimulus is specifically associated with a crime, the resulting brain activity should differentiate between someone who was present at the crime and someone who was not. This article reviews the scientific literature on three such techniques: priming, old/new, and P300 effects. The forensic potential of these techniques is evaluated based on four criteria: specificity, automaticity, encoding flexibility, and longevity. This article concludes that none of the techniques are devoid of forensic potential, although much research is yet to be done. Ethical issues, including rights to privacy and against self-incrimination, are discussed. A discussion of legal issues concludes that current memory detection techniques do not yet meet United States standards of legal admissibility.

  11. Catheter Closure Through a Venous Approach of Patent Ductus Arteriosus in Small Pediatric Patients Using Combined Angiographic and Echocardiographic Guidance.

    PubMed

    Thanopoulos, Basil Vasilios D; Ninios, Vlassis; Dardas, Petros; Giannopoulos, Andreas; Deleanou, Dan; Iancovici, Silvia

    2016-11-15

    The standard technique of catheter closure of patent ductus arteriosus (PDA) may be associated with arterial complications particularly in small pediatric patients. The aim of this study was to evaluate whether catheter closure of PDA in small children using an exclusive venous approach is a safe and effective alternative to closure with the standard technique. One hundred-twelve patients, aged 2 to 24 months, were randomly assigned in a 1:1 ratio to catheter closure of PDA using the standard technique (group 1) and an exclusive venous approach (group 2), respectively. In group 2, the procedure was guided using hand injections of contrast media through the delivery sheath and 2-dimensional and color Doppler echocardiography. Group 1: the PDA diameter ranged from 2 to 5.5 mm and the device diameter ranged from 4 to 8 mm. The PDA occluders were permanently implanted in all patients. Five losses of the arterial pulses that were restored with intravenous infusion of heparin and recombinant tissue plasminogen activator (rtPA), and 4 groin hematomas were the main complications of the procedure. Group 2: the mean PDA diameter ranged from 2.5 to 6 mm and the device diameter ranged from 3 to 8 mm. The PDA occluders were permanently implanted in all but 2 patients. There were no complications. Complete echocardiographic closure of PDA at 1-month follow-up was observed in all 110 patients. Exclusive transvenous PDA occlusion is an effective and safe technique that prevents the arterial complications of the standard approach in small children. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. FAIR exempting separate T (1) measurement (FAIREST): a novel technique for online quantitative perfusion imaging and multi-contrast fMRI.

    PubMed

    Lai, S; Wang, J; Jahng, G H

    2001-01-01

    A new pulse sequence, dubbed FAIR exempting separate T(1) measurement (FAIREST) in which a slice-selective saturation recovery acquisition is added in addition to the standard FAIR (flow-sensitive alternating inversion recovery) scheme, was developed for quantitative perfusion imaging and multi-contrast fMRI. The technique allows for clean separation between and thus simultaneous assessment of BOLD and perfusion effects, whereas quantitative cerebral blood flow (CBF) and tissue T(1) values are monitored online. Online CBF maps were obtained using the FAIREST technique and the measured CBF values were consistent with the off-line CBF maps obtained from using the FAIR technique in combination with a separate sequence for T(1) measurement. Finger tapping activation studies were carried out to demonstrate the applicability of the FAIREST technique in a typical fMRI setting for multi-contrast fMRI. The relative CBF and BOLD changes induced by finger-tapping were 75.1 +/- 18.3 and 1.8 +/- 0.4%, respectively, and the relative oxygen consumption rate change was 2.5 +/- 7.7%. The results from correlation of the T(1) maps with the activation images on a pixel-by-pixel basis show that the mean T(1) value of the CBF activation pixels is close to the T(1) of gray matter while the mean T(1) value of the BOLD activation pixels is close to the T(1) range of blood and cerebrospinal fluid. Copyright 2001 John Wiley & Sons, Ltd.

  13. Efficacy of a New Medical Information system, Ubiquitous Healthcare Service with Voice Inception Technique in Elderly Diabetic Patients.

    PubMed

    Kim, Kyoung Min; Park, Kyeong Seon; Lee, Hyun Ju; Lee, Yun Hee; Bae, Ji Seon; Lee, Young Joon; Choi, Sung Hee; Jang, Hak Chul; Lim, Soo

    2015-12-11

    We have demonstrated previously that an individualized health management system using advanced medical information technology, named ubiquitous (u)-healthcare, was helpful in achieving better glycemic control than routine care. Recently, we generated a new u-healthcare system using a voice inception technique for elderly diabetic patients to communicate information about their glucose control, physical activity, and diet more easily. In a randomized clinical trial, 70 diabetic patients aged 60-85 years were assigned randomly to a standard care group or u-healthcare group for 6 months. The primary end points were the changes in glycated hemoglobin (HbA1c) and glucose fluctuation assessed by the mean amplitude glycemic excursion (MAGE). Changes in body weight, lifestyle, and knowledge about diabetes were also investigated. After 6 months, the HbA1c levels decreased significantly in the u-healthcare group (from 8.6 ± 1.0% to 7.5 ± 0.6%) compared with the standard care group (from 8.7 ± 0.9% to 8.2 ± 1.1%, P < 0.01). The MAGE decreased more in the u-healthcare group than in the standard care group. Systolic blood pressure and body weight decreased and liver functions improved in the u-healthcare group, but not in the standard care group. The u-healthcare system with voice inception technique was effective in achieving glycemic control without hypoglycemia in elderly diabetic patients (Clinicaltrials.gov: NCT01891474).

  14. Evaluation of standard methods for collecting and processing fuel moisture samples

    Treesearch

    Sally M. Haase; José Sánchez; David R. Weise

    2016-01-01

    A variety of techniques for collecting and processing samples to determine moisture content of wildland fuels in support of fire management activities were evaluated. The effects of using a chainsaw or handsaw to collect samples of largediameter wood, containers for storing and transporting collected samples, and quick-response ovens for estimating moisture content...

  15. SYSTEMIC ACTIVITY OF NEONICOTINOIDS INFLUENCES FEEDING BY ADULT BLACK VINE WEEVILS ON VARIOUS SPECIES OF ORNAMENTALS

    USDA-ARS?s Scientific Manuscript database

    The black vine weevil (BVW) is a serious pest of ornamental nursery crops. The larval stage feeds on the roots of ornamental plants and small fruits often stunting or killing the plants. The adults feed on the foliage of ornamental plants. A standard management technique is to apply foliar treatm...

  16. Identification and Quantitation of Flavanols and Proanthocyanidins in Foods: How Good are the Datas?

    PubMed Central

    Kelm, Mark A.; Hammerstone, John F.; Schmitz, Harold H.

    2005-01-01

    Evidence suggesting that dietary polyphenols, flavanols, and proanthocyanidins in particular offer significant cardiovascular health benefits is rapidly increasing. Accordingly, reliable and accurate methods are needed to provide qualitative and quantitative food composition data necessary for high quality epidemiological and clinical research. Measurements for flavonoids and proanthocyanidins have employed a range of analytical techniques, with various colorimetric assays still being popular for estimating total polyphenolic content in foods and other biological samples despite advances made with more sophisticated analyses. More crudely, estimations of polyphenol content as well as antioxidant activity are also reported with values relating to radical scavenging activity. High-performance liquid chromatography (HPLC) is the method of choice for quantitative analysis of individual polyphenols such as flavanols and proanthocyanidins. Qualitative information regarding proanthocyanidin structure has been determined by chemical methods such as thiolysis and by HPLC-mass spectrometry (MS) techniques at present. The lack of appropriate standards is the single most important factor that limits the aforementioned analyses. However, with ever expanding research in the arena of flavanols, proanthocyanidins, and health and the importance of their future inclusion in food composition databases, the need for standards becomes more critical. At present, sufficiently well-characterized standard material is available for selective flavanols and proanthocyanidins, and construction of at least a limited food composition database is feasible. PMID:15712597

  17. Qualification of a precise and easy-to-handle sweat casting imprint method for the prediction and quantification of anti-perspirant efficacy.

    PubMed

    Keyhani, R; Scheede, S; Thielecke, I; Wenck, H; Schmucker, R; Schreiner, V; Ennen, J; Herpens, A

    2009-06-01

    A time- and cost-effective sweat casting method using the forearm as test site to assess the efficacy of several anti-perspirant formulations with a low number of test subjects has been evaluated and qualified. The imprint sweat casting method is based on a 2-component silcone-imprint technique to measure the efficacy of more than eight products in parallel with the same test subject. In studies using aluminum chlorohydrate (ACH) formulations as test anti-perspirants, a clear-cut correlation could be demonstrated between sweat gland activities measured by the imprint method and gravimetric measurement of sweat gland activities. Concentration-dependent inhibition of sweat gland activity could be observed with the imprint technique up to an ACH concentration of 15%, and all formulations containing 2% ACH or above resulted in statistically significant reduction of sweat gland activity (P < 0.001) when compared with untreated control areas. Furthermore, the SDs of individual studies using the imprint technique were in a range of +/-20% of sweat gland activity, which can be regarded rather low for in vivo measurements of a complex process like sweat secretion. A group-wise comparison between the measurements of anti-perspirant activity as determined by the imprint protocol and the Food and Drug Administration (FDA) Guideline compliant gravimetric hot-room protocol revealed that the test results for anti-perspirant activity obtained with the imprint protocol are similar to those obtained with the hot-room protocol. Moreover, the data generated with the imprint protocol have a high predictive value for the outcome of a later guideline-compliant hot-room test. As the imprint casting method tends to be a little more sensitive for formulations with low anti-perspirant activity, and seems to be associated with less interassay variability than the standard gravimetric hot-room test, the imprint casting method may select products which later fail to pass the standard gravimetric hot-room test. Meanwhile the imprint sweat casting has proven to be a robust method useful to support efficacy-oriented product development. Therefore, in later stages of utilization it might even evolve into an efficient claim substantiation tool.

  18. Results of the CCRI(II)-S12.H-3 supplementary comparison: Comparison of methods for the calculation of the activity and standard uncertainty of a tritiated-water source measured using the LSC-TDCR method.

    PubMed

    Cassette, Philippe; Altzitzoglou, Timotheos; Antohe, Andrei; Rossi, Mario; Arinc, Arzu; Capogni, Marco; Galea, Raphael; Gudelis, Arunas; Kossert, Karsten; Lee, K B; Liang, Juncheng; Nedjadi, Youcef; Oropesa Verdecia, Pilar; Shilnikova, Tanya; van Wyngaardt, Winifred; Ziemek, Tomasz; Zimmerman, Brian

    2018-04-01

    A comparison of calculations of the activity of a 3 H 2 O liquid scintillation source using the same experimental data set collected at the LNE-LNHB with a triple-to-double coincidence ratio (TDCR) counter was completed. A total of 17 laboratories calculated the activity and standard uncertainty of the LS source using the files with experimental data provided by the LNE-LNHB. The results as well as relevant information on the computation techniques are presented and analysed in this paper. All results are compatible, even if there is a significant dispersion between the reported uncertainties. An output of this comparison is the estimation of the dispersion of TDCR measurement results when measurement conditions are well defined. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Methods of measurement for semiconductor materials, process control, and devices

    NASA Technical Reports Server (NTRS)

    Bullis, W. M. (Editor)

    1972-01-01

    Activities directed toward the development of methods of measurement for semiconductor materials, process control, and devices are described. Topics investigated include: measurements of transistor delay time; application of the infrared response technique to the study of radiation-damaged, lithium-drifted silicon detectors; and identification of a condition that minimizes wire flexure and reduces the failure rate of wire bonds in transistors and integrated circuits under slow thermal cycling conditions. Supplementary data concerning staff, standards committee activities, technical services, and publications are included as appendixes.

  20. Wide-field optical mapping of neural activity and brain haemodynamics: considerations and novel approaches

    PubMed Central

    Ma, Ying; Shaik, Mohammed A.; Kozberg, Mariel G.; Thibodeaux, David N.; Zhao, Hanzhi T.; Yu, Hang

    2016-01-01

    Although modern techniques such as two-photon microscopy can now provide cellular-level three-dimensional imaging of the intact living brain, the speed and fields of view of these techniques remain limited. Conversely, two-dimensional wide-field optical mapping (WFOM), a simpler technique that uses a camera to observe large areas of the exposed cortex under visible light, can detect changes in both neural activity and haemodynamics at very high speeds. Although WFOM may not provide single-neuron or capillary-level resolution, it is an attractive and accessible approach to imaging large areas of the brain in awake, behaving mammals at speeds fast enough to observe widespread neural firing events, as well as their dynamic coupling to haemodynamics. Although such wide-field optical imaging techniques have a long history, the advent of genetically encoded fluorophores that can report neural activity with high sensitivity, as well as modern technologies such as light emitting diodes and sensitive and high-speed digital cameras have driven renewed interest in WFOM. To facilitate the wider adoption and standardization of WFOM approaches for neuroscience and neurovascular coupling research, we provide here an overview of the basic principles of WFOM, considerations for implementation of wide-field fluorescence imaging of neural activity, spectroscopic analysis and interpretation of results. This article is part of the themed issue ‘Interpreting BOLD: a dialogue between cognitive and cellular neuroscience’. PMID:27574312

  1. A Compendium on the NIST Radionuclidic Assays of the Massic Activity of 63Ni and 55Fe Solutions Used for an International Intercomparison of Liquid Scintillation Spectrometry Techniques

    PubMed Central

    Collé, R.; Zimmerman, B. E.

    1997-01-01

    The National Institute of Standards and Technology recently participated in an international measurement intercomparison for 63Ni and 55Fe, which was conducted amongst principal national radionuclidic metrology laboratories. The intercomparison was sponsored by EUROMET, and was primarily intended to evaluate the capabilities of liquid scintillation (LS) spectrometry techniques for standardizing nuclides that decay by low-energy β-emission (like 63Ni) and by low-Z (atomic number) electron capture (like 55Fe). The intercomparison findings exhibit a very good agreement for 63Ni amongst the various participating laboratories, including that for NIST, which suggests that the presently invoked LS methodologies are very capable of providing internationally-compatible standardizations for low-energy β-emitters. The results for 55Fe are in considerably poorer agreement, and demonstrated the existence of several unresolved problems. It has thus become apparent that there is a need for the various international laboratories to conduct rigorous, systematic evaluations of their LS capabilities in assaying radionuclides that decay by low-Z electron capture. PMID:27805141

  2. Sparse feature learning for instrument identification: Effects of sampling and pooling methods.

    PubMed

    Han, Yoonchang; Lee, Subin; Nam, Juhan; Lee, Kyogu

    2016-05-01

    Feature learning for music applications has recently received considerable attention from many researchers. This paper reports on the sparse feature learning algorithm for musical instrument identification, and in particular, focuses on the effects of the frame sampling techniques for dictionary learning and the pooling methods for feature aggregation. To this end, two frame sampling techniques are examined that are fixed and proportional random sampling. Furthermore, the effect of using onset frame was analyzed for both of proposed sampling methods. Regarding summarization of the feature activation, a standard deviation pooling method is used and compared with the commonly used max- and average-pooling techniques. Using more than 47 000 recordings of 24 instruments from various performers, playing styles, and dynamics, a number of tuning parameters are experimented including the analysis frame size, the dictionary size, and the type of frequency scaling as well as the different sampling and pooling methods. The results show that the combination of proportional sampling and standard deviation pooling achieve the best overall performance of 95.62% while the optimal parameter set varies among the instrument classes.

  3. Chiropractic Name techniques in Canada: a continued look at demographic trends and their impact on issues of jurisprudence

    PubMed Central

    Gleberzon, Brain J

    2002-01-01

    In a previous article, the author reported on the recommendations gathered from student projects between 1996 and 1999 investigating their preferences for including certain chiropractic Name technique systems into the curriculum at the Canadian Memorial Chiropractic College (CMCC). These results were found to be congruent with the professional treatment technique used by Canadian chiropractors. This article reports on the data obtained during the 2000 and 2001 academic years, comparing these results to those previously gathered. In addition, because of the implementation of a new curriculum during this time period, there was unique opportunity to observe whether or not student perceptions differed between those students in the `old' curricular program, and those students in the `new' curricular program. The results gathered indicate that students in both curricular programs show an interest in learning Thompson Terminal Point, Activator Methods, Gonstead, and Active Release Therapy techniques in the core curriculum, as an elective, or during continuing educational programs provided by the college. Students continue to show less interest in learning CranioSacral Therapy, SacroOccipital Technique, Logan Basic, Applied Kinesiology and Chiropractic BioPhysics. Over time, student interest has moved away from Palmer HIO and other upper cervical techniques, and students show a declining interest in being offered instruction in either Network Spinal Analysis or Torque Release Techniques. Since these findings reflect the practice activities of Canadian chiropractors they may have implications not only towards pedagogical decision-making processes at CMCC, but they may also influence professional standards of care.

  4. Using the Behavior Change Technique Taxonomy v1 to conceptualize the clinical content of Breaking Free Online: a computer-assisted therapy program for substance use disorders.

    PubMed

    Dugdale, Stephanie; Ward, Jonathan; Hernen, Jan; Elison, Sarah; Davies, Glyn; Donkor, Daniel

    2016-07-22

    In recent years, research within the field of health psychology has made significant progress in terms of advancing and standardizing the science of developing, evaluating and reporting complex behavioral change interventions. A major part of this work has involved the development of an evidence-based Behavior Change Technique Taxonomy v1 (BCTTv1), as a means of describing the active components contained within such complex interventions. To date, however, this standardized approach derived from health psychology research has not been applied to the development of complex interventions for the treatment of substance use disorders (SUD). Therefore, this paper uses Breaking Free Online (BFO), a computer-assisted therapy program for SUD, as an example of how the clinical techniques contained within such an intervention might be mapped onto the BCTTv1. The developers of BFO were able to produce a full list of the clinical techniques contained within BFO. Exploratory mapping of the BCTTv1 onto the clinical content of the BFO program was conducted separately by the authors of the paper. This included the developers of the BFO program and psychology professionals working within the SUD field. These coded techniques were reviewed by the authors and any discrepancies in the coding were discussed between all authors until an agreement was reached. The BCTTv1 was mapped onto the clinical content of the BFO program. At least one behavioral change technique was found in 12 out of 16 grouping categories within the BCTTv1. A total of 26 out of 93 behavior change techniques were identified across the clinical content of the program. This exploratory mapping exercise has identified the specific behavior change techniques contained within BFO, and has provided a means of describing these techniques in a standardized way using the BCTTv1 terminology. It has also provided an opportunity for the BCTTv1 mapping process to be reported to the wider SUD treatment community, as it may have real utility in the development and evaluation of other psychosocial and behavioral change interventions within this field.

  5. 48 CFR 9904.401-50 - Techniques for application.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... 9904.401-50 Section 9904.401-50 Federal Acquisition Regulations System COST ACCOUNTING STANDARDS BOARD, OFFICE OF FEDERAL PROCUREMENT POLICY, OFFICE OF MANAGEMENT AND BUDGET PROCUREMENT PRACTICES AND COST ACCOUNTING STANDARDS COST ACCOUNTING STANDARDS 9904.401-50 Techniques for application. (a) The standard...

  6. Photoswitchable method for the ordered attachment of proteins to surfaces

    DOEpatents

    Camarero, Julio A [Livermore, CA; DeYoreo, James J [Clayton, CA; Kwon, Youngeun [Livermore, CA

    2011-07-05

    Described herein is a method for the attachment of proteins to any solid support with control over the orientation of the attachment. The method is extremely efficient, not requiring the previous purification of the protein to be attached, and can be activated by UV-light. Spatially addressable arrays of multiple protein components can be generated by using standard photolithographic techniques.

  7. Neural and Behavioral Sequelae of Blast-Related Traumatic Brain Injury

    DTIC Science & Technology

    2012-11-01

    testing and advanced MRI techniques [task-activated functional MRI (fMRI) and diffusion tensor imaging ( DTI )] to gain a comprehensive understanding of... DTI fiber tracking) and neurobehavioral testing (computerized assessment and standard neuropsychological testing) on 60 chronic trauma patients: 15...data analysis. 15. SUBJECT TERMS Blast-related traumatic brain injury (TBI), fMRI, DTI , cognition 16. SECURITY CLASSIFICATION OF: 17. LIMITATION

  8. When Do Simpler Sexual Behavior Data Collection Techniques Suffice?: An Analysis of Consequent Uncertainty in HIV Acquisition Risk Estimates

    ERIC Educational Resources Information Center

    Pinkerton, Steven D.; Benotsch, Eric G.; Mikytuck, John

    2007-01-01

    The "gold standard" for evaluating human immunodeficiency virus (HIV) prevention programs is a partner-by-partner sexual behavior assessment that elicits information about each sex partner and the activities engaged in with that partner. When collection of detailed partner-by-partner data is not feasible, aggregate data (e.g., total…

  9. Making Sense of Safety: Cooperative Learning Activities Allow Students Time to Reflect on the Implications of Lab Safety Rules

    ERIC Educational Resources Information Center

    Barrier, Regina

    2005-01-01

    An important part of the science classroom involves teaching students how to safely use tools, techniques, and procedures. As emphasized in the National Science Education Standards, "safety is a fundamental concern in all experiential science" and teachers must "teach students how to engage safely in investigations inside and outside the…

  10. Photoswitchable method for the ordered attachment of proteins to surfaces

    DOEpatents

    Camarero, Julio A.; De Yoreo, James J.; Kwon, Youngeun

    2010-04-20

    Described herein is a method for the attachment of proteins to any solid support with control over the orientation of the attachment. The method is extremely efficient, not requiring the previous purification of the protein to be attached, and can be activated by UV-light. Spatially addressable arrays of multiple protein components can be generated by using standard photolithographic techniques.

  11. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR CLEANING: WEEKLY ACTIVITY FOLLOW UP--INDIVIDUAL (UA-D-23.0)

    EPA Science Inventory

    This entry is included for completeness of documentation. The technique described in the SOP was anticipated in study planning documents. It was subsequently not used, and the SOP was not completed. This SOP was replaced by SOP UA-D-22.0.

    The purpose of this SOP is to define t...

  12. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR CODING: WEEKLY ACTIVITY FOLLOW UP (INDIVIDUAL) (UA-D-12.0)

    EPA Science Inventory

    This abstract is included for completeness of documentation. The technique described in the SOP was anticipated in study planning documents. It was subsequently not used, and the SOP was not written. This SOP was replaced by SOP UA-D-11.0.

    The purpose of this SOP is to defin...

  13. An Analysis of the Units "I'm Learning My Past" and "The Place Where We Live" in the Social Studies Textbook Related to Critical Thinking Standards

    ERIC Educational Resources Information Center

    Aybek, Birsel; Aslan, Serkan

    2016-01-01

    Problem Statement: Various research have been conducted investigating the quality and quantity of textbooks such as wording, content, design, visuality, physical properties, activities, methods and techniques, questions and experiments, events, misconceptions, organizations, pictures, text selection, end of unit questions and assessments, indexes…

  14. Screening of selected single and polyherbal Ayurvedic medicines for Antibacterial and Antifungal activity

    PubMed Central

    Kekuda, T.R Prashith; Kavya, R; Shrungashree, R.M; Suchitra, S.V

    2010-01-01

    The present study deals with antimicrobial activity of ayurvedic drugs containing single herb (Amalaki Choorna and Yastimadhu Choorna) and combination of herbs (DN-90 and Asanadi Kwatha Choorna). Disc diffusion method was used to assess antibacterial activity and antifungal activity was tested using Poison food technique. Absence of bacterial growth around the discs impregnated with the aqueous extracts of drugs and reduction of fungal growth in poisoned plates indicated antimicrobial activity. Further, the results of antibacterial activity of Amalaki choorna were comparable with standard drug Streptomycin. Asanadi Kwatha Choorna inhibited bacteria to more extent than Yastimadhu choorna and DN-90. Among fungi tested, more antifungal activity was observed against Mucor sp. The antimicrobial activity of drugs tested could be due to active principles present in them. PMID:22557355

  15. Fundamentals of quantitative dynamic contrast-enhanced MR imaging.

    PubMed

    Paldino, Michael J; Barboriak, Daniel P

    2009-05-01

    Quantitative analysis of dynamic contrast-enhanced MR imaging (DCE-MR imaging) has the power to provide information regarding physiologic characteristics of the microvasculature and is, therefore, of great potential value to the practice of oncology. In particular, these techniques could have a significant impact on the development of novel anticancer therapies as a promising biomarker of drug activity. Standardization of DCE-MR imaging acquisition and analysis to provide more reproducible measures of tumor vessel physiology is of crucial importance to realize this potential. The purpose of this article is to review the pathophysiologic basis and technical aspects of DCE-MR imaging techniques.

  16. Nevada Applied Ecology Group procedures handbook for environmental transuranics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White, M.G.; Dunaway, P.B.

    The activities of the Nevada Applied Ecology Group (NAEG) integrated research studies of environmental plutonium and other transuranics at the Nevada Test Site have required many standardized field and laboratory procedures. These include sampling techniques, collection and preparation, radiochemical and wet chemistry analysis, data bank storage and reporting, and statistical considerations for environmental samples of soil, vegetation, resuspended particles, animals, and others. This document, printed in two volumes, includes most of the Nevada Applied Ecology Group standard procedures, with explanations as to the specific applications involved in the environmental studies. Where there is more than one document concerning a procedure,more » it has been included to indicate special studies or applications perhaps more complex than the routine standard sampling procedures utilized.« less

  17. Nevada Applied Ecology Group procedures handbook for environmental transuranics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White, M.G.; Dunaway, P.B.

    The activities of the Nevada Applied Ecology Group (NAEG) integrated research studies of environmental plutonium and other transuranics at the Nevada Test Site have required many standardized field and laboratory procedures. These include sampling techniques, collection and preparation, radiochemical and wet chemistry analysis, data bank storage and reporting, and statistical considerations for environmental samples of soil, vegetation, resuspended particles, animals, and other biological material. This document, printed in two volumes, includes most of the Nevada Applied Ecology Group standard procedures, with explanations as to the specific applications involved in the environmental studies. Where there is more than one document concerningmore » a procedure, it has been included to indicate special studies or applications more complex than the routine standard sampling procedures utilized.« less

  18. Synthesis and antimicrobial activity of 1-benzhydryl-sulfonyl-4-(3-(piperidin-4-yl) propyl)piperidine derivatives against pathogens of Lycopersicon esculentum: a structure-activity evaluation study.

    PubMed

    Vinaya, K; Kavitha, R; Ananda Kumar, C S; Benaka Prasad, S B; Chandrappa, S; Deepak, S A; Nanjunda Swamy, S; Umesha, S; Rangappa, K S

    2009-01-01

    Several 1-benzhydryl-sulfonyl-4-(3-(piperidin-4-yl)propyl)piperidine derivatives 8(a-j) were prepared by the treatment of substituted benzhydryl chlorides with 4-(3-(piperidin-4-yl)propyl)piperidine followed by N-sulfonation with sulfonyl chlorides in the presence of dry methylene dichloride and triethyl amine. The synthesized compounds were characterized by (1)H-NMR, IR, and elemental analysis. All the synthesized compounds were evaluated in vitro for their efficacy as antimicrobial agents by artificial inoculation technique against standard strains of two important bacterial viz., Xanthomonas axonopodis pv. vesicatoria and Ralstonia solanacearum as well as and two fungal pathogens namely Alternaria solani and Fusarium solani of tomato plants. We have briefly investigated the structure-activity relation studies and reveal that the nature of substitutions on benzhydryl ring and sulfonamide ring influences the antibacterial activity. Among the synthesized new compounds 8b, 8d, 8g, 8h, 8i, and 8j were showed significant potent antimicrobial activities compared to the standard drugs chloramphenicol, mancozeb.

  19. 48 CFR 9904.413-50 - Techniques for application.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... 9904.413-50 Section 9904.413-50 Federal Acquisition Regulations System COST ACCOUNTING STANDARDS BOARD... ACCOUNTING STANDARDS COST ACCOUNTING STANDARDS 9904.413-50 Techniques for application. (a) Assignment of actuarial gains and losses. (1) In accordance with the provisions of Cost Accounting Standard 9904.412...

  20. 99m-Technetium phosphate compound joint scintigraphy in the management of juvenile osteochondritis dissecans of the femoral condyles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cahill, B.R.; Berg, B.C.

    The known sensitivity of joint scintigraphy in following the course of fracture healing caused the authors to believe that this radiologic technique might be valuable in the management of osteochondritis dissecans (OCD). Accordingly, 99mTc-diphosphonate joint scintigraphy was used on 18 patients with OCD of the knee. The average age was 13 1/2 years. The scintigrams were repeated at 6-week intervals until healing had occurred. When the diagnosis of OCD was established by standard roentgenograms and joint scintigraphy, the patients were placed on an activity restriction program, attempting to reach a symptom-free level. The patients were followed for an average ofmore » 18 months. Ninety-five scans were categorized according to their level of scintigraphic activity. This led to a discrete four-part scintigraphic classification that is indicative of the extent of healing or progression of this condition, and precedes changes seen on standard x-rays by months. Joint scintigraphy also rules out anomalies of ossification in the diagnosis of OCD since an anomaly should have a normal scintigraphic appearance. We have concluded that joint scintigraphy is valuable in the management of OCD because of its superior sensitivity to changes in the activity of the lesion. As experience is gained with this technique, those cases that should be prophylactically surgically stabilized may be indicated.« less

  1. Real-time, multiplexed electrochemical DNA detection using an active complementary metal-oxide-semiconductor biosensor array with integrated sensor electronics.

    PubMed

    Levine, Peter M; Gong, Ping; Levicky, Rastislav; Shepard, Kenneth L

    2009-03-15

    Optical biosensing based on fluorescence detection has arguably become the standard technique for quantifying extents of hybridization between surface-immobilized probes and fluorophore-labeled analyte targets in DNA microarrays. However, electrochemical detection techniques are emerging which could eliminate the need for physically bulky optical instrumentation, enabling the design of portable devices for point-of-care applications. Unlike fluorescence detection, which can function well using a passive substrate (one without integrated electronics), multiplexed electrochemical detection requires an electronically active substrate to analyze each array site and benefits from the addition of integrated electronic instrumentation to further reduce platform size and eliminate the electromagnetic interference that can result from bringing non-amplified signals off chip. We report on an active electrochemical biosensor array, constructed with a standard complementary metal-oxide-semiconductor (CMOS) technology, to perform quantitative DNA hybridization detection on chip using targets conjugated with ferrocene redox labels. A 4 x 4 array of gold working electrodes and integrated potentiostat electronics, consisting of control amplifiers and current-input analog-to-digital converters, on a custom-designed 5 mm x 3 mm CMOS chip drive redox reactions using cyclic voltammetry, sense DNA binding, and transmit digital data off chip for analysis. We demonstrate multiplexed and specific detection of DNA targets as well as real-time monitoring of hybridization, a task that is difficult, if not impossible, with traditional fluorescence-based microarrays.

  2. Comparison of methods for determination of total oil sands-derived naphthenic acids in water samples.

    PubMed

    Hughes, Sarah A; Huang, Rongfu; Mahaffey, Ashley; Chelme-Ayala, Pamela; Klamerth, Nikolaus; Meshref, Mohamed N A; Ibrahim, Mohamed D; Brown, Christine; Peru, Kerry M; Headley, John V; Gamal El-Din, Mohamed

    2017-11-01

    There are several established methods for the determination of naphthenic acids (NAs) in waters associated with oil sands mining operations. Due to their highly complex nature, measured concentration and composition of NAs vary depending on the method used. This study compared different common sample preparation techniques, analytical instrument methods, and analytical standards to measure NAs in groundwater and process water samples collected from an active oil sands operation. In general, the high- and ultrahigh-resolution methods, namely high performance liquid chromatography time-of-flight mass spectrometry (UPLC-TOF-MS) and Orbitrap mass spectrometry (Orbitrap-MS), were within an order of magnitude of the Fourier transform infrared spectroscopy (FTIR) methods. The gas chromatography mass spectrometry (GC-MS) methods consistently had the highest NA concentrations and greatest standard error. Total NAs concentration was not statistically different between sample preparation of solid phase extraction and liquid-liquid extraction. Calibration standards influenced quantitation results. This work provided a comprehensive understanding of the inherent differences in the various techniques available to measure NAs and hence the potential differences in measured amounts of NAs in samples. Results from this study will contribute to the analytical method standardization for NA analysis in oil sands related water samples. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Technology and Technique Standards for Camera-Acquired Digital Dermatologic Images: A Systematic Review.

    PubMed

    Quigley, Elizabeth A; Tokay, Barbara A; Jewell, Sarah T; Marchetti, Michael A; Halpern, Allan C

    2015-08-01

    Photographs are invaluable dermatologic diagnostic, management, research, teaching, and documentation tools. Digital Imaging and Communications in Medicine (DICOM) standards exist for many types of digital medical images, but there are no DICOM standards for camera-acquired dermatologic images to date. To identify and describe existing or proposed technology and technique standards for camera-acquired dermatologic images in the scientific literature. Systematic searches of the PubMed, EMBASE, and Cochrane databases were performed in January 2013 using photography and digital imaging, standardization, and medical specialty and medical illustration search terms and augmented by a gray literature search of 14 websites using Google. Two reviewers independently screened titles of 7371 unique publications, followed by 3 sequential full-text reviews, leading to the selection of 49 publications with the most recent (1985-2013) or detailed description of technology or technique standards related to the acquisition or use of images of skin disease (or related conditions). No universally accepted existing technology or technique standards for camera-based digital images in dermatology were identified. Recommendations are summarized for technology imaging standards, including spatial resolution, color resolution, reproduction (magnification) ratios, postacquisition image processing, color calibration, compression, output, archiving and storage, and security during storage and transmission. Recommendations are also summarized for technique imaging standards, including environmental conditions (lighting, background, and camera position), patient pose and standard view sets, and patient consent, privacy, and confidentiality. Proposed standards for specific-use cases in total body photography, teledermatology, and dermoscopy are described. The literature is replete with descriptions of obtaining photographs of skin disease, but universal imaging standards have not been developed, validated, and adopted to date. Dermatologic imaging is evolving without defined standards for camera-acquired images, leading to variable image quality and limited exchangeability. The development and adoption of universal technology and technique standards may first emerge in scenarios when image use is most associated with a defined clinical benefit.

  4. Automatic detection of respiration rate from ambulatory single-lead ECG.

    PubMed

    Boyle, Justin; Bidargaddi, Niranjan; Sarela, Antti; Karunanithi, Mohan

    2009-11-01

    Ambulatory electrocardiography is increasingly being used in clinical practice to detect abnormal electrical behavior of the heart during ordinary daily activities. The utility of this monitoring can be improved by deriving respiration, which previously has been based on overnight apnea studies where patients are stationary, or the use of multilead ECG systems for stress testing. We compared six respiratory measures derived from a single-lead portable ECG monitor with simultaneously measured respiration air flow obtained from an ambulatory nasal cannula respiratory monitor. Ten controlled 1-h recordings were performed covering activities of daily living (lying, sitting, standing, walking, jogging, running, and stair climbing) and six overnight studies. The best method was an average of a 0.2-0.8 Hz bandpass filter and RR technique based on lengthening and shortening of the RR interval. Mean error rates with the reference gold standard were +/-4 breaths per minute (bpm) (all activities), +/-2 bpm (lying and sitting), and +/-1 breath per minute (overnight studies). Statistically similar results were obtained using heart rate information alone (RR technique) compared to the best technique derived from the full ECG waveform that simplifies data collection procedures. The study shows that respiration can be derived under dynamic activities from a single-lead ECG without significant differences from traditional methods.

  5. Business Model for the Security of a Large-Scale PACS, Compliance with ISO/27002:2013 Standard.

    PubMed

    Gutiérrez-Martínez, Josefina; Núñez-Gaona, Marco Antonio; Aguirre-Meneses, Heriberto

    2015-08-01

    Data security is a critical issue in an organization; a proper information security management (ISM) is an ongoing process that seeks to build and maintain programs, policies, and controls for protecting information. A hospital is one of the most complex organizations, where patient information has not only legal and economic implications but, more importantly, an impact on the patient's health. Imaging studies include medical images, patient identification data, and proprietary information of the study; these data are contained in the storage device of a PACS. This system must preserve the confidentiality, integrity, and availability of patient information. There are techniques such as firewalls, encryption, and data encapsulation that contribute to the protection of information. In addition, the Digital Imaging and Communications in Medicine (DICOM) standard and the requirements of the Health Insurance Portability and Accountability Act (HIPAA) regulations are also used to protect the patient clinical data. However, these techniques are not systematically applied to the picture and archiving and communication system (PACS) in most cases and are not sufficient to ensure the integrity of the images and associated data during transmission. The ISO/IEC 27001:2013 standard has been developed to improve the ISM. Currently, health institutions lack effective ISM processes that enable reliable interorganizational activities. In this paper, we present a business model that accomplishes the controls of ISO/IEC 27002:2013 standard and criteria of security and privacy from DICOM and HIPAA to improve the ISM of a large-scale PACS. The methodology associated with the model can monitor the flow of data in a PACS, facilitating the detection of unauthorized access to images and other abnormal activities.

  6. Time-resolved acoustic emission tomography in the laboratory: tracking localised damage in rocks

    NASA Astrophysics Data System (ADS)

    Brantut, N.

    2017-12-01

    Over the past three decades, there has been tremendous technological developments of laboratory equipment and studies using acoustic emission and ultrasonic monitoring of rock samples during deformation. Using relatively standard seismological techniques, acoustic emissions can be detected, located in space and time, and source mechanisms can be obtained. In parallel, ultrasonic velocities can be measured routinely using standard pulse-receiver techniques.Despite these major developments, current acoustic emission and ultrasonic monitoring systems are typically used separately, and the poor spatial coverage of acoustic transducers precludes performing active 3D tomography in typical laboratory settings.Here, I present an algorithm and software package that uses both passive acoustic emission data and active ultrasonic measurements to determine acoustic emission locations together with the 3D, anisotropic P-wave structure of rock samples during deformation. The technique is analogous to local earthquake tomography, but tailored to the specificities of small scale laboratory tests. The fast marching method is employed to compute the forward problem. The acoustic emission locations and the anisotropic P-wave field are jointly inverted using the Quasi-Newton method.The method is used to track the propagation of compaction bands in a porous sandstone deformed in the ductile, cataclastic flow regime under triaxial stress conditions. Near the yield point, a compaction front forms at one end of the sample, and slowly progresses towards the other end. The front is illuminated by clusters of Acoustic Emissions, and leaves behind a heavily damaged material where the P-wave speed has dropped by up to 20%.The technique opens new possibilities to track in-situ strain localisation and damage around laboratory faults, and preliminary results on quasi-static rupture in granite will be presented.

  7. Sewage Treatment

    NASA Technical Reports Server (NTRS)

    1976-01-01

    A million gallon-a-day sewage treatment plant in Huntington Beach, CA converts solid sewage to activated carbon which then treats incoming waste water. The plant is scaled up 100 times from a mobile unit NASA installed a year ago; another 100-fold scale-up will be required if technique is employed for widespread urban sewage treatment. This unique sewage-plant employed a serendipitous outgrowth of a need to manufacture activated carbon for rocket engine insulation. The process already exceeds new Environmental Protection Agency Standards Capital costs by 25% compared with conventional secondary treatment plants.

  8. Synthesis of 2,4,6-trichlorophenyl hydrazones and their inhibitory potential against glycation of protein.

    PubMed

    Khan, Khalid Mohammed; Shah, Zarbad; Ahmad, Viqar Uddin; Khan, Momin; Taha, Muhammad; Rahim, Fazal; Jahan, Humera; Perveen, Shahnaz; Choudhary, M Iqbal

    2011-11-01

    2,4,6-Trichlorophenyl hydrazones 1-35 were synthesized and their in vitro antiglycation potential was evaluated. Compounds 14 (IC50 = 27.2 ± 0.00 μM), and 18 (IC50 = 55.7 ± 0.00 μM) showed an excellent activity against glycation of protein, better than the standard (rutin, IC50 = 70 ± 0.50 μM). This study thus identified a novel series of antiglycation agents. A structure-activity relationship has been studied, and all the compounds were characterized by spectroscopic techniques.

  9. Optical changes in cortical tissue during seizure activity using optical coherence tomography (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Ornelas, Danielle; Hasan, Md.; Gonzalez, Oscar; Krishnan, Giri; Szu, Jenny I.; Myers, Timothy; Hirota, Koji; Bazhenov, Maxim; Binder, Devin K.; Park, Boris H.

    2017-02-01

    Epilepsy is a chronic neurological disorder characterized by recurrent and unpredictable seizures. Electrophysiology has remained the gold standard of neural activity detection but its resolution and high susceptibility to noise and motion artifact limit its efficiency. Optical imaging techniques, including fMRI, intrinsic optical imaging, and diffuse optical imaging, have also been used to detect neural activity yet these techniques rely on the indirect measurement of changes in blood flow. A more direct optical imaging technique is optical coherence tomography (OCT), a label-free, high resolution, and minimally invasive imaging technique that can produce depth-resolved cross-sectional and 3D images. In this study, OCT was used to detect non-vascular depth-dependent optical changes in cortical tissue during 4-aminopyridine (4-AP) induced seizure onset. Calculations of localized optical attenuation coefficient (µ) allow for the assessment of depth-resolved volumetric optical changes in seizure induced cortical tissue. By utilizing the depth-dependency of the attenuation coefficient, we demonstrate the ability to locate and remove the optical effects of vasculature within the upper regions of the cortex on the attenuation calculations of cortical tissue in vivo. The results of this study reveal a significant depth-dependent decrease in attenuation coefficient of nonvascular cortical tissue both ex vivo and in vivo. Regions exhibiting decreased attenuation coefficient show significant temporal correlation to regions of increased electrical activity during seizure onset and progression. This study allows for a more thorough and biologically relevant analysis of the optical signature of seizure activity in vivo using OCT.

  10. Determination of the composition of HgCdTe oxide films by neutron activation analysis

    NASA Astrophysics Data System (ADS)

    Gnade, B.; Simmons, A.; Little, D.; Strong, R.

    1987-04-01

    The composition of HgCdTe oxides grown by anodic oxidation in a standard KOH/ethylene glycol solution has been determined by neutron activation analysis (NAA). This technique is not hindered by the difficulties normally associated with methods using ion beams or electron beams. Neutron activation analysis has the advantage of being quantitative, and also NAA is not affected by the chemical composition of the matrix. The analysis of the KOH/ethylene glycol oxide film by neutron activation yields Hg:Cd:Te ratios of 0.534:0.19:1, in close agreement with Rutherford backscattering spectroscopy analysis (R.L. Strong et al., J. Vac. Sci. Technol. A4 (4) (1986) 1992).

  11. Twist Model Development and Results from the Active Aeroelastic Wing F/A-18 Aircraft

    NASA Technical Reports Server (NTRS)

    Lizotte, Andrew M.; Allen, Michael J.

    2007-01-01

    Understanding the wing twist of the active aeroelastic wing (AAW) F/A-18 aircraft is a fundamental research objective for the program and offers numerous benefits. In order to clearly understand the wing flexibility characteristics, a model was created to predict real-time wing twist. A reliable twist model allows the prediction of twist for flight simulation, provides insight into aircraft performance uncertainties, and assists with computational fluid dynamic and aeroelastic issues. The left wing of the aircraft was heavily instrumented during the first phase of the active aeroelastic wing program allowing deflection data collection. Traditional data processing steps were taken to reduce flight data, and twist predictions were made using linear regression techniques. The model predictions determined a consistent linear relationship between the measured twist and aircraft parameters, such as surface positions and aircraft state variables. Error in the original model was reduced in some cases by using a dynamic pressure-based assumption. This technique produced excellent predictions for flight between the standard test points and accounted for nonlinearities in the data. This report discusses data processing techniques and twist prediction validation, and provides illustrative and quantitative results.

  12. High density event-related potential data acquisition in cognitive neuroscience.

    PubMed

    Slotnick, Scott D

    2010-04-16

    Functional magnetic resonance imaging (fMRI) is currently the standard method of evaluating brain function in the field of Cognitive Neuroscience, in part because fMRI data acquisition and analysis techniques are readily available. Because fMRI has excellent spatial resolution but poor temporal resolution, this method can only be used to identify the spatial location of brain activity associated with a given cognitive process (and reveals virtually nothing about the time course of brain activity). By contrast, event-related potential (ERP) recording, a method that is used much less frequently than fMRI, has excellent temporal resolution and thus can track rapid temporal modulations in neural activity. Unfortunately, ERPs are under utilized in Cognitive Neuroscience because data acquisition techniques are not readily available and low density ERP recording has poor spatial resolution. In an effort to foster the increased use of ERPs in Cognitive Neuroscience, the present article details key techniques involved in high density ERP data acquisition. Critically, high density ERPs offer the promise of excellent temporal resolution and good spatial resolution (or excellent spatial resolution if coupled with fMRI), which is necessary to capture the spatial-temporal dynamics of human brain function.

  13. Twist Model Development and Results From the Active Aeroelastic Wing F/A-18 Aircraft

    NASA Technical Reports Server (NTRS)

    Lizotte, Andrew; Allen, Michael J.

    2005-01-01

    Understanding the wing twist of the active aeroelastic wing F/A-18 aircraft is a fundamental research objective for the program and offers numerous benefits. In order to clearly understand the wing flexibility characteristics, a model was created to predict real-time wing twist. A reliable twist model allows the prediction of twist for flight simulation, provides insight into aircraft performance uncertainties, and assists with computational fluid dynamic and aeroelastic issues. The left wing of the aircraft was heavily instrumented during the first phase of the active aeroelastic wing program allowing deflection data collection. Traditional data processing steps were taken to reduce flight data, and twist predictions were made using linear regression techniques. The model predictions determined a consistent linear relationship between the measured twist and aircraft parameters, such as surface positions and aircraft state variables. Error in the original model was reduced in some cases by using a dynamic pressure-based assumption and by using neural networks. These techniques produced excellent predictions for flight between the standard test points and accounted for nonlinearities in the data. This report discusses data processing techniques and twist prediction validation, and provides illustrative and quantitative results.

  14. Application of fermentation for isoflavone extraction from soy molasses

    NASA Astrophysics Data System (ADS)

    Duru, K. C.; Kovaleva, E. G.; Glukhareva, T. V.

    2017-09-01

    Extraction of isoflavones from soy products remains a major challenge for researchers. Different extraction techniques have been employed but the need to use a cheap green extraction technique remains the main focus. This study applied fermentation of soy molasses using Saccharomyces cerevisiae for extraction of isoflavones and compared this technique to the conventional extraction method. The aluminum chloride colorimetric method was used for the determination of total flavonoid content of extracts. The highest yield was observed from extraction using ethyl acetate after fermentation of soy molasses and the lowest one was given by the extract from conventional extraction method. The DPPH radical scavenging activities of the extracts were also compared. The extract obtained using ethyl acetate after fermentation showed the highest antioxidant activity (0.0269 meq), while extract from conventional extraction had the lowest antioxidant activity (0.0055 meq). The effect of time on daidzein yield was studied using HPLC standard addition method. Daidzein concentration was higher in extract obtained at t = 80 min (3.82 ± 0.11 mg of daidzein /g of extract) as compared to that obtained at t = 60 min (2.89 ± 0.10 mg of daidzein /g of extract).

  15. Phase change events of volatile liquid perfluorocarbon contrast agents produce unique acoustic signatures

    PubMed Central

    Sheeran, Paul S.; Matsunaga, Terry O.; Dayton, Paul A.

    2015-01-01

    Phase-change contrast agents (PCCAs) provide a dynamic platform to approach problems in medical ultrasound (US). Upon US-mediated activation, the liquid core vaporizes and expands to produce a gas bubble ideal for US imaging and therapy. In this study, we demonstrate through high-speed video microscopy and US interrogation that PCCAs composed of highly volatile perfluorocarbons (PFCs) exhibit unique acoustic behavior that can be detected and differentiated from standard microbubble contrast agents. Experimental results show that when activated with short pulses PCCAs will over-expand and undergo unforced radial oscillation while settling to a final bubble diameter. The size-dependent oscillation phenomenon generates a unique acoustic signal that can be passively detected in both time and frequency domain using confocal piston transducers with an ‘activate high’ (8 MHz, 2 cycles), ‘listen low’ (1 MHz) scheme. Results show that the magnitude of the acoustic ‘signature’ increases as PFC boiling point decreases. By using a band-limited spectral processing technique, the droplet signals can be isolated from controls and used to build experimental relationships between concentration and vaporization pressure. The techniques shown here may be useful for physical studies as well as development of droplet-specific imaging techniques. PMID:24351961

  16. Active Control Technique Evaluation for Spacecraft (ACES)

    DTIC Science & Technology

    1988-06-16

    spare Voyager Astromast built by ASTRO Research, Inc. It was supplied to MSFC by the Jet Propulsion Laboratory (JPL). The Astromast is extremely...assuming full controlled state availability, is u = - FXc . The control law designed via the modified control weighting matrix deserves comment...minimizes J has the form u(k) = - FXc (k) and can be found via standard software for solving the discrete algebraic Riccati

  17. Integrated Broadband Quantum Cascade Laser

    NASA Technical Reports Server (NTRS)

    Mansour, Kamjou (Inventor); Soibel, Alexander (Inventor)

    2016-01-01

    A broadband, integrated quantum cascade laser is disclosed, comprising ridge waveguide quantum cascade lasers formed by applying standard semiconductor process techniques to a monolithic structure of alternating layers of claddings and active region layers. The resulting ridge waveguide quantum cascade lasers may be individually controlled by independent voltage potentials, resulting in control of the overall spectrum of the integrated quantum cascade laser source. Other embodiments are described and claimed.

  18. A prospective, observational study comparing the PK/PD relationships of generic Meropenem (Mercide®) to the innovator brand in critically ill patients.

    PubMed

    Mer, Mervyn; Snyman, Jacques Rene; van Rensburg, Constance Elizabeth Jansen; van Tonder, Jacob John; Laurens, Ilze

    2016-01-01

    Clinicians' skepticism, fueled by evidence of inferiority of some multisource generic antimicrobial products, results in the underutilization of more cost-effective generics, especially in critically ill patients. The aim of this observational study was to demonstrate equivalence between the generic or comparator brand of meropenem (Mercide ® ) and the leading innovator brand (Meronem ® ) by means of an ex vivo technique whereby antimicrobial activity is used to estimate plasma concentration of the active moiety. Patients from different high care and intensive care units were recruited for observation when prescribed either of the meropenem brands under investigation. Blood samples were collected over 6 hours after a 30 minute infusion of the different brands. Meropenem concentration curves were established against United States Pharmacopeia standard meropenem (Sigma-Aldrich) by using standard laboratory techniques for culture of Klebsiella pneumoniae. Patients' plasma samples were tested ex vivo, using a disc diffusion assay, to confirm antimicrobial activity and estimate plasma concentrations of the two brands. Both brands of meropenem demonstrated similar curves in donor plasma when concentrations in vials were confirmed. Patient-specific serum concentrations were determined from zones of inhibition against a standard laboratory Klebsiella strain ex vivo, confirming at least similar in vivo concentrations as the concentration curves (90% confidence interval) overlapped; however, the upper limit of the area under the curve for the ratio comparator/innovator exceeded the 1.25-point estimate, i.e., 4% higher for comparator meropenem. This observational, in-practice study demonstrates similar ex vivo activity and in vivo plasma concentration time curves for the products under observation. Assay sensitivity is also confirmed. Current registration status of generic small molecules is in place. The products are therefore clinically interchangeable based on registration status as well as bioassay results, demonstrating sufficient overlap for clinical comfort. The slightly higher observed comparator meropenem concentration (4%) is still clinically acceptable due to the large therapeutic index and should ally fears of inferiority.

  19. EEG-fMRI evaluation of patients with mesial temporal lobe sclerosis.

    PubMed

    Avesani, Mirko; Giacopuzzi, Silvia; Bongiovanni, Luigi Giuseppe; Borelli, Paolo; Cerini, Roberto; Pozzi Mucelli, Roberto; Fiaschi, Antonio

    2014-02-01

    This preliminary study sought more information on blood oxygen level dependent (BOLD) activation, especially contralateral temporal/extratemporal spread, during continuous EEG-fMRI recordings in four patients with mesial temporal sclerosis (MTS). In two patients, EEG showed unilateral focal activity during the EEG-fMRI session concordant with the interictal focus previously identified with standard and video-poly EEG. In the other two patients EEG demonstrated a contralateral diffusion of the irritative focus. In the third patient (with the most drug-resistant form and also extratemporal clinical signs), there was an extratemporal diffusion over frontal regions, ipsilateral to the irritative focus. fMRI analysis confirmed a single activation in the mesial temporal region in two patients whose EEG showed unilateral focal activity, while it demonstrated a bilateral activation in the mesial temporal regions in the other two patients. In the third patient, fMRI demonstrated an activation in the supplementary motxor area. This study confirms the most significant activation with a high firing rate of the irritative focus, but also suggests the importance of using new techniques (such as EEG-fMRI to examine cerebral blood flow) to identify the controlateral limbic activation, and any other extratemporal activations, possible causes of drug resistance in MTS that may require a more precise pre-surgical evaluation with invasive techniques.

  20. EEG-fMRI Evaluation of Patients with Mesial Temporal Lobe Sclerosis

    PubMed Central

    Avesani, Mirko; Giacopuzzi, Silvia; Bongiovanni, Luigi Giuseppe; Borelli, Paolo; Cerini, Roberto; Pozzi Mucelli, Roberto; Fiaschi, Antonio

    2014-01-01

    Summary This preliminary study sought more information on blood oxygen level dependent (BOLD) activation, especially contralateral temporal/extratemporal spread, during continuous EEG-fMRI recordings in four patients with mesial temporal sclerosis (MTS). In two patients, EEG showed unilateral focal activity during the EEG-fMRI session concordant with the interictal focus previously identified with standard and video-poly EEG. In the other two patients EEG demonstrated a contralateral diffusion of the irritative focus. In the third patient (with the most drug-resistant form and also extratemporal clinical signs), there was an extratemporal diffusion over frontal regions, ipsilateral to the irritative focus. fMRI analysis confirmed a single activation in the mesial temporal region in two patients whose EEG showed unilateral focal activity, while it demonstrated a bilateral activation in the mesial temporal regions in the other two patients. In the third patient, fMRI demonstrated an activation in the supplementary motxor area. This study confirms the most significant activation with a high firing rate of the irritative focus, but also suggests the importance of using new techniques (such as EEG-fMRI to examine cerebral blood flow) to identify the controlateral limbic activation, and any other extratemporal activations, possible causes of drug resistance in MTS that may require a more precise pre-surgical evaluation with invasive techniques. PMID:24571833

  1. A biofilm microreactor system for simultaneous electrochemical and nuclear magnetic resonance techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Renslow, Ryan S.; Babauta, Jerome T.; Majors, Paul D.

    2014-03-01

    In order to fully understand electrochemically active biofilms and the limitations to their scale-up in industrial biofilm reactors, a complete picture of the microenvironments inside the biofilm is needed. Nuclear magnetic resonance (NMR) techniques are ideally suited for the study of biofilms and for probing their microenvironments because these techniques allow for non-invasive interrogation and in situ monitoring with high resolution. By combining NMR with simultaneous electrochemical techniques, it is possible to sustain and study live electrochemically active biofilms. Here, we introduce a novel biofilm microreactor system that allows for simultaneous electrochemical and NMR techniques (EC-NMR) at the microscale. Microreactorsmore » were designed with custom radiofrequency resonator coils, which allowed for NMR measurements of biofilms growing on polarized gold electrodes. For an example application of this system, we grew Geobacter sulfurreducens biofilms. NMR was used to investigate growth media flow velocities, which were compared to simulated laminar flow, and electron donor concentrations inside the biofilms. We use Monte Carlo error analysis to estimate standard deviations of the electron donor concentration measurements within the biofilm. The EC-NMR biofilm microreactor system can ultimately be used to correlate extracellular electron transfer rates with metabolic reactions and explore extracellular electron transfer mechanisms.« less

  2. Laparoscopic sleeve gastrectomy: More than a restrictive bariatric surgery procedure?

    PubMed Central

    Benaiges, David; Más-Lorenzo, Antonio; Goday, Albert; Ramon, José M; Chillarón, Juan J; Pedro-Botet, Juan; Roux, Juana A Flores-Le

    2015-01-01

    Sleeve gastrectomy (SG) is a restrictive bariatric surgery technique that was first used as part of restrictive horizontal gastrectomy in the original Scopinaro type biliopancreatic diversion. Its good results as a single technique have led to a rise in its use, and it is currently the second most performed technique worldwide. SG achieves clearly better results than other restrictive techniques and is comparable in some aspects to the Roux-en-Y gastric bypass, the current gold standard in bariatric surgery. These benefits have been associated with different pathophysiologic mechanisms unrelated to weight loss such as increased gastric emptying and intestinal transit, and activation of hormonal mechanisms such as increased GLP-1 hormone and decreased ghrelin. The aim of this review was to highlight the salient aspects of SG regarding its historical evolution, pathophysiologic mechanisms, main results, clinical applications and perioperative complications. PMID:26557004

  3. [Main indicators of educational activity at the Department of Operative Techniques and Surgical Research at the University of Debrecen between 2000-2013].

    PubMed

    Pető, Katalin; Németh, Norbert; Lesznyák, Tamás; Furka, István; Mikó, Irén

    2013-06-01

    The authors provide a review about the main parameters of the gradual and postgradual educational activity of the Department of Operative Techniques and Surgical Research between 2000-2013. In this period of time several new subjects and courses have been introduced. The thematics have been widened, and the educational topics underwent a significant change and development: new teaching videos, revised note-books and a new textbook have been prepared through these years. Further, new training models (surgical training models, phantom and biomodels) have also been evolved. The educational activity of the Department was supported significantly several times (financial, contribution, grants) from the University of Debrecen, partner companies, HEFOP and TÁMOP grants. Infrastructural development in conjunction with the above increased the quality of educational standards in gradual and postgradual education, too. All these changes and developments were presented on various professional meetings and published in relevant journals, as part ofinternal quality control.

  4. UIAGM Ropehandling Techniques.

    ERIC Educational Resources Information Center

    Cloutier, K. Ross

    The Union Internationale des Associations des Guides de Montagne's (UIAGM) rope handling techniques are intended to form the standard for guiding ropework worldwide. These techniques have become the legal standard for instructional institutions and commercial guiding organizations in UIAGM member countries: Austria, Canada, France, Germany, Great…

  5. E-Standards For Mass Properties Engineering

    NASA Technical Reports Server (NTRS)

    Cerro, Jeffrey A.

    2008-01-01

    A proposal is put forth to promote the concept of a Society of Allied Weight Engineers developed voluntary consensus standard for mass properties engineering. This standard would be an e-standard, and would encompass data, data manipulation, and reporting functionality. The standard would be implemented via an open-source SAWE distribution site with full SAWE member body access. Engineering societies and global standards initiatives are progressing toward modern engineering standards, which become functioning deliverable data sets. These data sets, if properly standardized, will integrate easily between supplier and customer enabling technically precise mass properties data exchange. The concepts of object-oriented programming support all of these requirements, and the use of a JavaTx based open-source development initiative is proposed. Results are reported for activity sponsored by the NASA Langley Research Center Innovation Institute to scope out requirements for developing a mass properties engineering e-standard. An initial software distribution is proposed. Upon completion, an open-source application programming interface will be available to SAWE members for the development of more specific programming requirements that are tailored to company and project requirements. A fully functioning application programming interface will permit code extension via company proprietary techniques, as well as through continued open-source initiatives.

  6. Etalon (standard) for surface potential distribution produced by electric activity of the heart.

    PubMed

    Szathmáry, V; Ruttkay-Nedecký, I

    1981-01-01

    The authors submit etalon (standard) equipotential maps as an aid in the evaluation of maps of surface potential distributions in living subjects. They were obtained by measuring potentials on the surface of an electrolytic tank shaped like the thorax. The individual etalon maps were determined in such a way that the parameters of the physical dipole forming the source of the electric field in the tank corresponded to the mean vectorcardiographic parameters measured in a healthy population sample. The technique also allows a quantitative estimate of the degree of non-dipolarity of the heart as the source of the electric field.

  7. Standardization and determination of the total internal conversion coefficient of In-111.

    PubMed

    Matos, Izabela T; Koskinas, Marina F; Nascimento, Tatiane S; Yamazaki, Ione M; Dias, Mauro S

    2014-05-01

    The standardization of (111)In by means of a 4πβ-γ coincidence system, composed of a proportional counter in 4π geometry, coupled to a 20% relative efficiency HPGe crystal, for measuring gamma-rays is presented. The data acquisition was performed by means of the software coincidence system (SCS) and the activity was determined by the extrapolation technique. Two gamma-ray windows were selected: at 171 keV and 245 keV total absorption peaks, allowing the determination of the total internal conversion coefficient for these two gamma transitions. The results were compared with those available in the literature. © 2013 Published by Elsevier Ltd.

  8. Design, synthesis and exploring the quantitative structure-activity relationship of some antioxidant flavonoid analogues.

    PubMed

    Das, Sreeparna; Mitra, Indrani; Batuta, Shaikh; Niharul Alam, Md; Roy, Kunal; Begum, Naznin Ara

    2014-11-01

    A series of flavonoid analogues were synthesized and screened for the in vitro antioxidant activity through their ability to quench 1,1-diphenyl-2-picryl hydrazyl (DPPH) radical. The activity of these compounds, measured in comparison to the well-known standard antioxidants (29-32), their precursors (38-42) and other bioactive moieties (38-42) resembling partially the flavone skeleton was analyzed further to develop Quantitative Structure-Activity Relationship (QSAR) models using the Genetic Function Approximation (GFA) technique. Based on the essential structural requirements predicted by the QSAR models, some analogues were designed, synthesized and tested for activity. The predicted and experimental activities of these compounds were well correlated. Flavone analogue 20 was found to be the most potent antioxidant. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Analysis of calibration data for the uranium active neutron coincidence counting collar with attention to errors in the measured neutron coincidence rate

    DOE PAGES

    Croft, Stephen; Burr, Thomas Lee; Favalli, Andrea; ...

    2015-12-10

    We report that the declared linear density of 238U and 235U in fresh low enriched uranium light water reactor fuel assemblies can be verified for nuclear safeguards purposes using a neutron coincidence counter collar in passive and active mode, respectively. The active mode calibration of the Uranium Neutron Collar – Light water reactor fuel (UNCL) instrument is normally performed using a non-linear fitting technique. The fitting technique relates the measured neutron coincidence rate (the predictor) to the linear density of 235U (the response) in order to estimate model parameters of the nonlinear Padé equation, which traditionally is used to modelmore » the calibration data. Alternatively, following a simple data transformation, the fitting can also be performed using standard linear fitting methods. This paper compares performance of the nonlinear technique to the linear technique, using a range of possible error variance magnitudes in the measured neutron coincidence rate. We develop the required formalism and then apply the traditional (nonlinear) and alternative approaches (linear) to the same experimental and corresponding simulated representative datasets. Lastly, we find that, in this context, because of the magnitude of the errors in the predictor, it is preferable not to transform to a linear model, and it is preferable not to adjust for the errors in the predictor when inferring the model parameters« less

  10. [Development of Patient Transfer Techniques based on Postural-stability Principles for the Care Helpers in Nursing Homes and Evaluation of Effectiveness].

    PubMed

    Ma, Ryewon; Jung, Dukyoo

    2016-02-01

    This study was done to develop a postural-stability patient transfer technique for care helpers in nursing homes and to evaluate its effectiveness. Four types of patient transfer techniques (Lifting towards the head board of the bed, turning to the lateral position, sitting upright on the bed, transferring from wheel chair to bed) were practiced in accordance with the following three methods; Care helpers habitually used transfer methods (Method 1), patient transfer methods according to care helper standard textbooks (Method 2), and a method developed by the author ensuring postural-stability (Method 3). The care helpers' muscle activity and four joint angles were measured. The collected data were analyzed using the program SPSS Statistic 21.0. To differentiate the muscle activity and joint angle, the Friedman test was executed and the post-hoc analysis was conducted using the Wilcoxon Signed Rank test. Muscle activity was significantly lower during Method 3 compared to Methods 1 and 2. In addition, the joint angle was significantly lower for the knee and shoulder joint angle while performing Method 3 compared to Methods 1 and 2. Findings indicate that using postural-stability patient transfer techniques can contribute to the prevention of musculoskeletal disease which care helpers suffer from due to physically demanding patient care in nursing homes.

  11. Electromigration kinetics and critical current of Pb-free interconnects

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lu, Minhua; Rosenberg, Robert

    2014-04-07

    Electromigration kinetics of Pb-free solder bump interconnects have been studied using a single bump parameter sweep technique. By removing bump to bump variations in structure, texture, and composition, the single bump sweep technique has provided both activation energy and power exponents that reflect atomic migration and interface reactions with fewer samples, shorter stress time, and better statistics than standard failure testing procedures. Contact metallurgies based on Cu and Ni have been studied. Critical current, which corresponds to the Blech limit, was found to exist in the Ni metallurgy, but not in the Cu metallurgy. A temperature dependence of critical currentmore » was also observed.« less

  12. Metadynamics studies of crystal nucleation

    PubMed Central

    Giberti, Federico; Salvalaglio, Matteo; Parrinello, Michele

    2015-01-01

    Crystallization processes are characterized by activated events and long timescales. These characteristics prevent standard molecular dynamics techniques from being efficiently used for the direct investigation of processes such as nucleation. This short review provides an overview on the use of metadynamics, a state-of-the-art enhanced sampling technique, for the simulation of phase transitions involving the production of a crystalline solid. In particular the principles of metadynamics are outlined, several order parameters are described that have been or could be used in conjunction with metadynamics to sample nucleation events and then an overview is given of recent metadynamics results in the field of crystal nucleation. PMID:25866662

  13. The Commercial Challenges Of Pacs

    NASA Astrophysics Data System (ADS)

    Vanden Brink, John A.

    1984-08-01

    The increasing use of digital imaging techniques create a need for improved methods of digital processing, communication and archiving. However, the commercial opportunity is dependent on the resolution of a number of issues. These issues include proof that digital processes are more cost effective than present techniques, implementation of information system support in the imaging activity, implementation of industry standards, conversion of analog images to digital formats, definition of clinical needs, the implications of the purchase decision and technology requirements. In spite of these obstacles, a market is emerging, served by new and existing companies, that may become a $500 million market (U.S.) by 1990 for equipment and supplies.

  14. Remeasurement and compilation of excitation function of proton induced reactions on iron for activation techniques

    NASA Astrophysics Data System (ADS)

    Takács, S.; Vasváry, L.; Tárkányi, F.

    1994-05-01

    Excitation functions of proton induced reactions on natFe(p, xn) 56Co have been remeasured in the energy region up to 18 MeV using stacked foil technique and standard high resolution gamma-ray spectrometry at the Debrecen MGC-20E cyclotron. Compilation of the available data measured between 1959 and 1993 has been made. The corresponding excitation functions have been reviewed, critical comparison of all the available data was done to obtain the most accurate data set. The feasibility of the evaluated data set was checked by reproducing experimental calibration curves for TLA by calculation.

  15. A Study on Active Disaster Management System for Standardized Emergency Action Plan using BIM and Flood Damage Estimation Techniques

    NASA Astrophysics Data System (ADS)

    Jeong, C.; Om, J.; Hwang, J.; Joo, K.; Heo, J.

    2013-12-01

    In recent, the frequency of extreme flood has been increasing due to climate change and global warming. Highly flood damages are mainly caused by the collapse of flood control structures such as dam and dike. In order to reduce these disasters, the disaster management system (DMS) through flood forecasting, inundation mapping, EAP (Emergency Action Plan) has been studied. The estimation of inundation damage and practical EAP are especially crucial to the DMS. However, it is difficult to predict inundation and take a proper action through DMS in real emergency situation because several techniques for inundation damage estimation are not integrated and EAP is supplied in the form of a document in Korea. In this study, the integrated simulation system including rainfall frequency analysis, rainfall-runoff modeling, inundation prediction, surface runoff analysis, and inland flood analysis was developed. Using this system coupled with standard GIS data, inundation damage can be estimated comprehensively and automatically. The standard EAP based on BIM (Building Information Modeling) was also established in this system. It is, therefore, expected that the inundation damages through this study over the entire area including buildings can be predicted and managed.

  16. Summary Report for the Technical Interchange Meeting on Development of Baseline Material Properties and Design Guidelines for In-Space Manufacturing Activities

    NASA Technical Reports Server (NTRS)

    Prater, T. J.; Bean, Q. A.; Werkheiser, N. J.; Johnston, M. M.; Ordonez, E. A.; Ledbetter, F. E.; Risdon, D. L.; Stockman, T. J.; Sandridge, S. K. R.; Nelson, G. M.

    2016-01-01

    NASA Marshall Space Flight Center (MSFC) and the Agency as a whole are currently engaged in a number of in-space manufacturing (ISM) activities that have the potential to reduce launch costs, enhance crew safety, and provide the capabilities needed to undertake long-duration spaceflight. The recent 3D Printing in Zero-G experiment conducted on board the International Space Station (ISS) demonstrated that parts of acrylonitrile butadiene styrene (ABS) plastic can be manufactured in microgravity using fused deposition modeling (FDM). This project represents the beginning of the development of a capability that is critical to future NASA missions. Current and future ISM activities will require the development of baseline material properties to facilitate design, analysis, and certification of materials manufactured using in-space techniques. The purpose of this technical interchange meeting (TIM) was to bring together MSFC practitioners and experts in materials characterization and development of baseline material properties for emerging technologies to advise the ISM team as we progress toward the development of material design values, standards, and acceptance criteria for materials manufactured in space. The overall objective of the TIM was to leverage MSFC's shared experiences and collective knowledge in advanced manufacturing and materials development to construct a path forward for the establishment of baseline material properties, standards development, and certification activities related to ISM. Participants were asked to help identify research and development activities that will (1) accelerate acceptance and adoption of ISM techniques among the aerospace design community; (2) benefit future NASA programs, commercial technology developments, and national needs; and (3) provide opportunities and avenues for further collaboration.

  17. Comparison of methods to assess energy expenditure and physical activity in people with spinal cord injury.

    PubMed

    Tanhoffer, Ricardo A; Tanhoffer, Aldre I P; Raymond, Jacqueline; Hills, Andrew P; Davis, Glen M

    2012-01-01

    To compare different methods of assessing energy expenditure (EE) and physical activity (PA) in people with spinal cord injury (SCI) under community-dwelling conditions. A reference standard encompassing the doubly labelled water (DLW) technique, heart rate monitoring (FLEX-HR), a multi-sensor armband (SenseWear Armband (SWA)), and two PA recall questionnaires were employed in 14 people with SCI to estimate EE and leisure-time PA. Mean total daily energy expenditure (TDEE) assessed by DLW, FLEX-HR, and SWA were 9817 ± 2491 kJ/day, 8498 ± 1516 kJ/day, and 11414 ± 3242 kJ/day, respectively. Physical activity energy expenditure (PAEE) quantified by DLW was 2841 ± 1626 kJ/day, 2935 ± 1732 kJ/day estimated from FLEX-HR, and 2773 ± 2966 kJ/day derived from SWA. After converting the PA recall questionnaire data to EE in kJ/day, PAEE for the Physical Activity Recall Assessment for People with Spinal Cord Injury (PARA-SCI) was 2339 ± 1171 kJ/day and for Physical Activity Scale for Individuals with Physical Disabilities (PASIPD) 749 ± 1026 kJ/day. DLW-quantified PAEE was moderately associated with PARA-SCI (R(2) = 0.62, P < 0.05), but not with the other estimates of PAEE (R(2) ranged between 0.13 and 0.30, P > 0.05). Our findings revealed that the PARA-SCI recall questionnaire was the best estimate of PAEE compared to the reference standard DLW approach. Although the between-method variability for SWA, FLEX-HR, and PASIPD-derived PAEE was small, there was a weak association between these methods and the criterion DLW technique. The best estimate of DLW-quantified TDEE was by FLEX-HR. SWA significantly overestimated TDEE in this population.

  18. Correlating laser-induced breakdown spectroscopy with neutron activation analysis to determine the elemental concentration in the ionome of the Populus trichocarpa leaf

    NASA Astrophysics Data System (ADS)

    Martin, Madhavi Z.; Glasgow, David C.; Tschaplinski, Timothy J.; Tuskan, Gerald A.; Gunter, Lee E.; Engle, Nancy L.; Wymore, Ann M.; Weston, David J.

    2017-12-01

    The black cottonwood poplar (Populus trichocarpa) leaf ionome (inorganic trace elements and mineral nutrients) is an important aspect for determining the physiological and developmental processes contributing to biomass production. A number of techniques are used to measure the ionome, yet characterizing the leaf spatial heterogeneity remains a challenge, especially in solid samples. Laser-induced breakdown spectroscopy (LIBS) has been used to determine the elemental composition of leaves and is able to raster across solid matrixes at 10 μm resolution. Here, we evaluate the use of LIBS for solid sample leaf elemental characterization in relation to neutron activation. In fact, neutron activation analysis is a laboratory-based technique which is used by the National Institute of Standards and Technology (NIST) to certify trace elements in candidate reference materials including plant leaf matrices. Introduction to the techniques used in this research has been presented in this manuscript. Neutron activation analysis (NAA) data has been correlated to the LIBS spectra to achieve quantification of the elements or ions present within poplar leaves. The regression coefficients of calibration and validation using multivariate analysis (MVA) methodology for six out of seven elements have been determined and vary between 0.810 and 0.998. LIBS and NAA data has been presented for the elements such as, calcium, magnesium, manganese, aluminum, copper, and potassium. Chlorine was also detected but it did not show good correlation between the LIBS and NAA techniques. This research shows that LIBS can be used as a fast, high-spatial resolution technique to quantify elements as part of large-scale field phenotyping projects.

  19. Determine equilibrium dissociation constant of drug-membrane receptor affinity using the cell membrane chromatography relative standard method.

    PubMed

    Ma, Weina; Yang, Liu; Lv, Yanni; Fu, Jia; Zhang, Yanmin; He, Langchong

    2017-06-23

    The equilibrium dissociation constant (K D ) of drug-membrane receptor affinity is the basic parameter that reflects the strength of interaction. The cell membrane chromatography (CMC) method is an effective technique to study the characteristics of drug-membrane receptor affinity. In this study, the K D value of CMC relative standard method for the determination of drug-membrane receptor affinity was established to analyze the relative K D values of drugs binding to the membrane receptors (Epidermal growth factor receptor and angiotensin II receptor). The K D values obtained by the CMC relative standard method had a strong correlation with those obtained by the frontal analysis method. Additionally, the K D values obtained by CMC relative standard method correlated with pharmacological activity of the drug being evaluated. The CMC relative standard method is a convenient and effective method to evaluate drug-membrane receptor affinity. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. 48 CFR 9905.505-50 - Techniques for application.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... this cost accounting principle does not require that allocation of unallowable costs to final cost.... 9905.505-50 Section 9905.505-50 Federal Acquisition Regulations System COST ACCOUNTING STANDARDS BOARD... ACCOUNTING STANDARDS COST ACCOUNTING STANDARDS FOR EDUCATIONAL INSTITUTIONS 9905.505-50 Techniques for...

  1. 48 CFR 9904.403-50 - Techniques for application.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... 9904.403-50 Section 9904.403-50 Federal Acquisition Regulations System COST ACCOUNTING STANDARDS BOARD, OFFICE OF FEDERAL PROCUREMENT POLICY, OFFICE OF MANAGEMENT AND BUDGET PROCUREMENT PRACTICES AND COST ACCOUNTING STANDARDS COST ACCOUNTING STANDARDS 9904.403-50 Techniques for application. (a)(1) Separate...

  2. Standardization of Laser Methods and Techniques for Vibration Measurements and Calibrations

    NASA Astrophysics Data System (ADS)

    von Martens, Hans-Jürgen

    2010-05-01

    The realization and dissemination of the SI units of motion quantities (vibration and shock) have been based on laser interferometer methods specified in international documentary standards. New and refined laser methods and techniques developed by national metrology institutes and by leading manufacturers in the past two decades have been swiftly specified as standard methods for inclusion into in the series ISO 16063 of international documentary standards. A survey of ISO Standards for the calibration of vibration and shock transducers demonstrates the extended ranges and improved accuracy (measurement uncertainty) of laser methods and techniques for vibration and shock measurements and calibrations. The first standard for the calibration of laser vibrometers by laser interferometry or by a reference accelerometer calibrated by laser interferometry (ISO 16063-41) is on the stage of a Draft International Standard (DIS) and may be issued by the end of 2010. The standard methods with refined techniques proved to achieve wider measurement ranges and smaller measurement uncertainties than that specified in the ISO Standards. The applicability of different standardized interferometer methods to vibrations at high frequencies was recently demonstrated up to 347 kHz (acceleration amplitudes up to 350 km/s2). The relative deviations between the amplitude measurement results of the different interferometer methods that were applied simultaneously, differed by less than 1% in all cases.

  3. Development of Traceable Phantoms for Improved Image Quantification in Positron Emission Tomography

    NASA Astrophysics Data System (ADS)

    Zimmerman, Brian

    2014-03-01

    Clinical trials for new drugs increasingly rely on imaging data to monitor patient response to the therapy being studied. In the case of radiopharmaceutical applications, imaging data are also used to estimate organ and tumor doses in order to arrive at the optimal dosage for safe and effective treatment. Positron Emission Tomography (PET) is one of the most commonly used imaging modalities for these types of applications. In large, multicenter trials it is crucial to minimize as much as possible the variability that arises due to use of different types of scanners and other instrumentation so that the biological response can be more readily evaluated. This can be achieved by ensuring that all the instruments are calibrated to a common standard and that their performance is continuously monitored throughout the trial. Maintaining links to a single standard also enables the comparability of data acquired on a heterogeneous collection of instruments in different clinical settings. As the standards laboratory for the United States, the National Institute of Standards and Technology (NIST) has been developing a suite of phantoms having traceable activity content to enable scanner calibration and performance testing. The configurations range from small solid cylindrical sources having volumes from 1 mL to 23 mL to large cylinders having a total volume of 9 L. The phantoms are constructed with 68Ge as a long-lived substitute for the more clinically useful radionuclide 18F. The contained activity values are traceable to the national standard for 68Ge and are also linked to the standard for 18F through a careful series of comparisons. The techniques that have been developed are being applied to a variety of new phantom configurations using different radionuclides. Image-based additive manufacturing techniques are also being investigated to create fillable phantoms having irregular shapes which can better mimic actual organs and tumors while still maintaining traceability back to primary standards for radioactivity. This talk will describe the methods used to construct, calibrate, and characterize the phantoms, focusing on the preservation of the traceability link to the primary standards of the radionuclides used. The on-going development of specialized traceable phantoms for specific organ dosimetry applications and imaging physics studies will also be discussed.

  4. Antimicrobial activity of biogenic silver nanoparticles, and silver chloride nanoparticles: an overview and comments.

    PubMed

    Durán, Nelson; Nakazato, Gerson; Seabra, Amedea B

    2016-08-01

    The antimicrobial impact of biogenic-synthesized silver-based nanoparticles has been the focus of increasing interest. As the antimicrobial activity of nanoparticles is highly dependent on their size and surface, the complete and adequate characterization of the nanoparticle is important. This review discusses the characterization and antimicrobial activity of biogenic synthesized silver nanoparticles and silver chloride nanoparticles. By revising the literature, there is confusion in the characterization of these two silver-based nanoparticles, which consequently affects the conclusion regarding to their antimicrobial activities. This review critically analyzes recent publications on the synthesis of biogenic silver nanoparticles and silver chloride nanoparticles by attempting to correlate the characterization of the nanoparticles with their antimicrobial activity. It was difficult to correlate the size of biogenic nanoparticles with their antimicrobial activity, since different techniques are employed for the characterization. Biogenic synthesized silver-based nanoparticles are not completely characterized, particularly the nature of capped proteins covering the nanomaterials. Moreover, the antimicrobial activity of theses nanoparticles is assayed by using different protocols and strains, which difficult the comparison among the published papers. It is important to select some bacteria as standards, by following international foundations (Pharmaceutical Microbiology Manual) and use the minimal inhibitory concentration by broth microdilution assays from Clinical and Laboratory Standards Institute, which is the most common assay used in antibiotic ones. Therefore, we conclude that to have relevant results on antimicrobial effects of biogenic silver-based nanoparticles, it is necessary to have a complete and adequate characterization of these nanostructures, followed by standard methodology in microbiology protocols.

  5. 48 CFR 9904.409-50 - Techniques for application.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... 9904.409-50 Section 9904.409-50 Federal Acquisition Regulations System COST ACCOUNTING STANDARDS BOARD... ACCOUNTING STANDARDS COST ACCOUNTING STANDARDS 9904.409-50 Techniques for application. (a) Determination of... of consumption of services in the cost accounting periods included in such life. In selecting service...

  6. 48 CFR 9904.414-50 - Techniques for application.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... the case of process cost accounting systems, the contracting parties may agree to substitute an.... 9904.414-50 Section 9904.414-50 Federal Acquisition Regulations System COST ACCOUNTING STANDARDS BOARD... ACCOUNTING STANDARDS COST ACCOUNTING STANDARDS 9904.414-50 Techniques for application. (a) The investment...

  7. 48 CFR 9904.404-50 - Techniques for application.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... 9904.404-50 Section 9904.404-50 Federal Acquisition Regulations System COST ACCOUNTING STANDARDS BOARD, OFFICE OF FEDERAL PROCUREMENT POLICY, OFFICE OF MANAGEMENT AND BUDGET PROCUREMENT PRACTICES AND COST ACCOUNTING STANDARDS COST ACCOUNTING STANDARDS 9904.404-50 Techniques for application. (a) The cost to...

  8. 48 CFR 9904.405-50 - Techniques for application.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... 9904.405-50 Section 9904.405-50 Federal Acquisition Regulations System COST ACCOUNTING STANDARDS BOARD, OFFICE OF FEDERAL PROCUREMENT POLICY, OFFICE OF MANAGEMENT AND BUDGET PROCUREMENT PRACTICES AND COST ACCOUNTING STANDARDS COST ACCOUNTING STANDARDS 9904.405-50 Techniques for application. (a) The detail and...

  9. 48 CFR 9904.406-50 - Techniques for application.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... 9904.406-50 Section 9904.406-50 Federal Acquisition Regulations System COST ACCOUNTING STANDARDS BOARD, OFFICE OF FEDERAL PROCUREMENT POLICY, OFFICE OF MANAGEMENT AND BUDGET PROCUREMENT PRACTICES AND COST ACCOUNTING STANDARDS COST ACCOUNTING STANDARDS 9904.406-50 Techniques for application. (a) The cost of an...

  10. Eliminating Fear of the Blank Page: A Thematic Approach, aka Squeezing the California Department of Education's 1992 ESL Model Standards for Adult Education Programs into One Tidy Package.

    ERIC Educational Resources Information Center

    DesRoches, Diane

    An approach to teaching integrated language skills in adult English-as-a-Second-Language (ESL) instruction is described. The technique uses a combination of classroom drama and role-playing, writing about the event, revision, publication, and follow-up activities to develop speaking, listening, reading, and writing skills. Eight stages are defined…

  11. Assessment of and standardization for quantitative nondestructive test

    NASA Technical Reports Server (NTRS)

    Neuschaefer, R. W.; Beal, J. B.

    1972-01-01

    Present capabilities and limitations of nondestructive testing (NDT) as applied to aerospace structures during design, development, production, and operational phases are assessed. It will help determine what useful structural quantitative and qualitative data may be provided from raw materials to vehicle refurbishment. This assessment considers metal alloys systems and bonded composites presently applied in active NASA programs or strong contenders for future use. Quantitative and qualitative data has been summarized from recent literature, and in-house information, and presented along with a description of those structures or standards where the information was obtained. Examples, in tabular form, of NDT technique capabilities and limitations have been provided. NDT techniques discussed and assessed were radiography, ultrasonics, penetrants, thermal, acoustic, and electromagnetic. Quantitative data is sparse; therefore, obtaining statistically reliable flaw detection data must be strongly emphasized. The new requirements for reusable space vehicles have resulted in highly efficient design concepts operating in severe environments. This increases the need for quantitative NDT evaluation of selected structural components, the end item structure, and during refurbishment operations.

  12. Alpha shape theory for 3D visualization and volumetric measurement of brain tumor progression using magnetic resonance images.

    PubMed

    Hamoud Al-Tamimi, Mohammed Sabbih; Sulong, Ghazali; Shuaib, Ibrahim Lutfi

    2015-07-01

    Resection of brain tumors is a tricky task in surgery due to its direct influence on the patients' survival rate. Determining the tumor resection extent for its complete information via-à-vis volume and dimensions in pre- and post-operative Magnetic Resonance Images (MRI) requires accurate estimation and comparison. The active contour segmentation technique is used to segment brain tumors on pre-operative MR images using self-developed software. Tumor volume is acquired from its contours via alpha shape theory. The graphical user interface is developed for rendering, visualizing and estimating the volume of a brain tumor. Internet Brain Segmentation Repository dataset (IBSR) is employed to analyze and determine the repeatability and reproducibility of tumor volume. Accuracy of the method is validated by comparing the estimated volume using the proposed method with that of gold-standard. Segmentation by active contour technique is found to be capable of detecting the brain tumor boundaries. Furthermore, the volume description and visualization enable an interactive examination of tumor tissue and its surrounding. Admirable features of our results demonstrate that alpha shape theory in comparison to other existing standard methods is superior for precise volumetric measurement of tumor. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Development of an Uncertainty Model for the National Transonic Facility

    NASA Technical Reports Server (NTRS)

    Walter, Joel A.; Lawrence, William R.; Elder, David W.; Treece, Michael D.

    2010-01-01

    This paper introduces an uncertainty model being developed for the National Transonic Facility (NTF). The model uses a Monte Carlo technique to propagate standard uncertainties of measured values through the NTF data reduction equations to calculate the combined uncertainties of the key aerodynamic force and moment coefficients and freestream properties. The uncertainty propagation approach to assessing data variability is compared with ongoing data quality assessment activities at the NTF, notably check standard testing using statistical process control (SPC) techniques. It is shown that the two approaches are complementary and both are necessary tools for data quality assessment and improvement activities. The SPC approach is the final arbiter of variability in a facility. Its result encompasses variation due to people, processes, test equipment, and test article. The uncertainty propagation approach is limited mainly to the data reduction process. However, it is useful because it helps to assess the causes of variability seen in the data and consequently provides a basis for improvement. For example, it is shown that Mach number random uncertainty is dominated by static pressure variation over most of the dynamic pressure range tested. However, the random uncertainty in the drag coefficient is generally dominated by axial and normal force uncertainty with much less contribution from freestream conditions.

  14. Metabolic and clinical assessment of efficacy of cryoablation therapy on skeletal masses by 18F-FDG positron emission tomography/computed tomography (PET/CT) and visual analogue scale (VAS): initial experience.

    PubMed

    Masala, Salvatore; Schillaci, Orazio; Bartolucci, Alberto D; Calabria, Ferdinando; Mammucari, Matteo; Simonetti, Giovanni

    2011-02-01

    Various therapy modalities have been proposed as standard treatments in management of bone metastases. Radiation therapy remains the standard of care for patients with localized bone pain, but up to 30% of them do not experience notable pain relief. Percutaneous cryoablation is a minimally invasive technique that induces necrosis by alternately freezing and thawing a target tissue. This technique is successfully used to treat a variety of malignant and benign diseases in different sites. (18)F-FDG positron emission tomography/computed tomography ((18)F-FDG PET/CT) is a single technique of imaging that provides in a "single step" both morphological and metabolic features of neoplastic lesions of the bone. The aim of this study was to evaluate the efficacy of the cryosurgical technique on secondary musculoskeletal masses according to semi-quantitative PET analysis and clinical-test evaluation with the visual analogue scale (VAS). We enrolled 20 patients with painful bone lesions (score pain that exceeded 4 on the VAS) that were non-responsive to treatment; one lesion per patient was treated. All patients underwent a PET-CT evaluation before and 8 weeks after cryotherapy; maximum standardized uptake value (SUV(max)) was measured before and after treatment for metabolic assessment of response to therapy. After treatment, 18 patients (90%) showed considerable reduction in SUV(max) value (>50%) suggestive of response to treatment; only 2 patients did not show meaningful reduction in metabolic activity. Our preliminary study demonstrates that quantitative analysis provided by PET correlates with response to cryoablation therapy as assessed by CT data and clinical VAS evaluation.

  15. Analysis of behavioral change techniques in community-led total sanitation programs.

    PubMed

    Sigler, Rachel; Mahmoudi, Lyana; Graham, Jay Paul

    2015-03-01

    The lack of sanitation facilitates the spread of diarrheal diseases-a leading cause of child deaths worldwide. As of 2012, an estimated 1 billion people still practiced open defecation (OD). To address this issue, one behavioral change approach used is community-led total sanitation (CLTS). It is now applied in an estimated 66 countries worldwide, and many countries have adopted this approach as their main strategy for scaling up rural sanitation coverage. While it appears that many of the activities used in CLTS-that target community-level changes in sanitation behaviors instead of household-level changes-have evolved out of existing behavior change frameworks and techniques, it is less clear how these activities are adapted by different organizations and applied in different country contexts. The aims of this study are to (i) show which behavior change frameworks and techniques are the most common in CLTS interventions; (ii) describe how activities are implemented in CLTS interventions by region and context; and (3) determine which activities program implementers considered the most valuable in achieving open defecation free (ODF) status and sustaining it. The results indicate that a wide range of activities are conducted across the different programs and often go beyond standard CLTS activities. CLTS practitioners ranked follow-up and monitoring activities as the most important activities for achieving an ODF community, yet only 1 of 10 organizations conducted monitoring and follow-up throughout their project. Empirical studies are needed to determine which specific behavioral change activities are most effective at ending OD and sustaining it. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. A new technique for measuring listening and reading literacy in developing countries

    NASA Astrophysics Data System (ADS)

    Greene, Barbara A.; Royer, James M.; Anzalone, Stephen

    1990-03-01

    One problem in evaluating educational interventions in developing countries is the absence of tests that adequately reflect the culture and curriculum. The Sentence Verification Technique is a new procedure for measuring reading and listening comprehension that allows for the development of tests based on materials indigenous to a given culture. The validity of using the Sentence Verification Technique to measure reading comprehension in Grenada was evaluated in the present study. The study involved 786 students at standards 3, 4 and 5. The tests for each standard consisted of passages that varied in difficulty. The students identified as high ability students in all three standards performed better than those identified as low ability. All students performed better with easier passages. Additionally, students in higher standards performed bettter than students in lower standards on a given passage. These results supported the claim that the Sentence Verification Technique is a valid measure of reading comprehension in Grenada.

  17. Feasibility of Active Machine Learning for Multiclass Compound Classification.

    PubMed

    Lang, Tobias; Flachsenberg, Florian; von Luxburg, Ulrike; Rarey, Matthias

    2016-01-25

    A common task in the hit-to-lead process is classifying sets of compounds into multiple, usually structural classes, which build the groundwork for subsequent SAR studies. Machine learning techniques can be used to automate this process by learning classification models from training compounds of each class. Gathering class information for compounds can be cost-intensive as the required data needs to be provided by human experts or experiments. This paper studies whether active machine learning can be used to reduce the required number of training compounds. Active learning is a machine learning method which processes class label data in an iterative fashion. It has gained much attention in a broad range of application areas. In this paper, an active learning method for multiclass compound classification is proposed. This method selects informative training compounds so as to optimally support the learning progress. The combination with human feedback leads to a semiautomated interactive multiclass classification procedure. This method was investigated empirically on 15 compound classification tasks containing 86-2870 compounds in 3-38 classes. The empirical results show that active learning can solve these classification tasks using 10-80% of the data which would be necessary for standard learning techniques.

  18. Gross alpha and beta activity analyses in urine-a routine laboratory method for internal human radioactivity detection.

    PubMed

    Chen, Xiaowen; Zhao, Luqian; Qin, Hongran; Zhao, Meijia; Zhou, Yirui; Yang, Shuqiang; Su, Xu; Xu, Xiaohua

    2014-05-01

    The aim of this work was to develop a method to provide rapid results for humans with internal radioactive contamination. The authors hypothesized that valuable information could be obtained from gas proportional counter techniques by screening urine samples from potentially exposed individuals rapidly. Recommended gross alpha and beta activity screening methods generally employ gas proportional counting techniques. Based on International Standards Organization (ISO) methods, improvements were made in the evaporation process to develop a method to provide rapid results, adequate sensitivity, and minimum sample preparation and operator intervention for humans with internal radioactive contamination. The method described by an American National Standards Institute publication was used to calibrate the gas proportional counter, and urine samples from patients with or without radionuclide treatment were measured to validate the method. By improving the evaporation process, the time required to perform the assay was reduced dramatically. Compared with the reference data, the results of the validation samples were very satisfactory with respect to gross-alpha and gross-beta activities. The gas flow proportional counting method described here has the potential for radioactivity monitoring in the body. This method was easy, efficient, and fast, and its application is of great utility in determining whether a sample should be analyzed by a more complicated method, for example radiochemical and/or γ-spectroscopy. In the future, it may be used commonly in medical examination and nuclear emergency treatment.Health Phys. 106(5):000-000; 2014.

  19. Blood-Banking Techniques for Plateletpheresis in Swine

    PubMed Central

    Sondeen, Jill L; Prince, Malcolm D; Polykratis, Irene A; Hernandez, Orlando; Torres-Mendoza, Jaime; Guzman, Rodolfo De; Aden, James K; Dubick, Michael A

    2014-01-01

    During the past several years, trauma resuscitation in human patients has evolved from decreased use of crystalloids to increased use of blood products. Of high interest is the role of platelets in trauma resuscitation. Because conducting prehospital resuscitation in human trauma patients is very difficult, swine are often the animal model of choice for such studies because their coagulation and hemodynamic systems are similar to those in humans. However, consistent production of sufficient swine platelets for such studies has not previously been achieved. We developed a method for producing swine platelets by using standard human techniques and equipment. We assessed pH, pO2, pCO2, lactate, thromboelastography, and platelet aggregation over 5 d of storage to determine whether the swine platelet product met the American Association of Blood Banks (AABB) standards for transfusion. Swine platelets met AABB standards at 24 h but not at later time points. In addition, we fluorescently labeled nonautologous platelets and then measured their percentage recovery over 5 h (the time used in subsequent experimental studies) when transfused into a recipient pig. We showed that 80% of the platelets stored for 24 h remained in the circulation and increased the recipient pigs’ thromboelastographic responses, indicating that the platelets were viable and active. Therefore, swine platelets stored for 24 h by using standard human products met the AABB criteria and were functional. PMID:24827574

  20. 48 CFR 9904.417-50 - Techniques for application.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... capitalized, such as the method used for financial accounting and reporting, may be used, provided the.... 9904.417-50 Section 9904.417-50 Federal Acquisition Regulations System COST ACCOUNTING STANDARDS BOARD... ACCOUNTING STANDARDS COST ACCOUNTING STANDARDS 9904.417-50 Techniques for application. (a) The cost of money...

  1. 48 CFR 9904.412-50 - Techniques for application.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... 9904.412-50 Section 9904.412-50 Federal Acquisition Regulations System COST ACCOUNTING STANDARDS BOARD... ACCOUNTING STANDARDS COST ACCOUNTING STANDARDS 9904.412-50 Techniques for application. (a) Components of... identified part of the pension cost of a cost accounting period and shall be included in equal annual...

  2. 48 CFR 9904.415-50 - Techniques for application.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... 9904.415-50 Section 9904.415-50 Federal Acquisition Regulations System COST ACCOUNTING STANDARDS BOARD... ACCOUNTING STANDARDS COST ACCOUNTING STANDARDS 9904.415-50 Techniques for application. (a) The contractor... shall be assignable only to the cost accounting period or periods in which the compensation is paid to...

  3. 48 CFR 9904.408-50 - Techniques for application.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... 9904.408-50 Section 9904.408-50 Federal Acquisition Regulations System COST ACCOUNTING STANDARDS BOARD... ACCOUNTING STANDARDS COST ACCOUNTING STANDARDS 9904.408-50 Techniques for application. (a) Determinations... determination shall be made beginning with the first cost accounting period to which such new or changed plan or...

  4. 48 CFR 9904.416-50 - Techniques for application.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... ACCOUNTING STANDARDS COST ACCOUNTING STANDARDS 9904.416-50 Techniques for application. (a) Measurement of.... 9904.416-50 Section 9904.416-50 Federal Acquisition Regulations System COST ACCOUNTING STANDARDS BOARD... be assigned pro rata among the cost accounting periods covered by the policy term, except as provided...

  5. 48 CFR 9904.410-50 - Techniques for application.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... 9904.410-50 Section 9904.410-50 Federal Acquisition Regulations System COST ACCOUNTING STANDARDS BOARD, OFFICE OF FEDERAL PROCUREMENT POLICY, OFFICE OF MANAGEMENT AND BUDGET PROCUREMENT PRACTICES AND COST ACCOUNTING STANDARDS COST ACCOUNTING STANDARDS 9904.410-50 Techniques for application. (a) G&A expenses of a...

  6. Light and sound - emerging imaging techniques for inflammatory bowel disease

    PubMed Central

    Knieling, Ferdinand; Waldner, Maximilian J

    2016-01-01

    Patients with inflammatory bowel disease are known to have a high demand of recurrent evaluation for therapy and disease activity. Further, the risk of developing cancer during the disease progression is increasing from year to year. New, mostly non-radiant, quick to perform and quantitative methods are challenging, conventional endoscopy with biopsy as gold standard. Especially, new physical imaging approaches utilizing light and sound waves have facilitated the development of advanced functional and molecular modalities. Besides these advantages they hold the promise to predict personalized therapeutic responses and to spare frequent invasive procedures. Within this article we highlight their potential for initial diagnosis, assessment of disease activity and surveillance of cancer development in established techniques and recent advances such as wide-view full-spectrum endoscopy, chromoendoscopy, autofluorescence endoscopy, endocytoscopy, confocal laser endoscopy, multiphoton endoscopy, molecular imaging endoscopy, B-mode and Doppler ultrasound, contrast-enhanced ultrasound, ultrasound molecular imaging, and elastography. PMID:27433080

  7. PCR-activated cell sorting as a general, cultivation-free method for high-throughput identification and enrichment of virus hosts.

    PubMed

    Lim, Shaun W; Lance, Shea T; Stedman, Kenneth M; Abate, Adam R

    2017-04-01

    Characterizing virus-host relationships is critical for understanding the impact of a virus on an ecosystem, but is challenging with existing techniques, particularly for uncultivable species. We present a general, cultivation-free approach for identifying phage-associated bacterial cells. Using PCR-activated cell sorting, we interrogate millions of individual bacteria for the presence of specific phage nucleic acids. If the nucleic acids are present, the bacteria are recovered via sorting and their genomes analyzed. This allows targeted recovery of all possible host species in a diverse population associated with a specific phage, and can be easily targeted to identify the hosts of different phages by modifying the PCR primers used for detection. Moreover, this technique allows quantification of free phage particles, as benchmarked against the "gold standard" of virus enumeration, the plaque assay. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Laser-activated solid protein bands for peripheral nerve repair: an vivo study.

    PubMed

    Lauto, A; Trickett, R; Malik, R; Dawes, J M; Owen, E R

    1997-01-01

    Severed tibial nerves in rats were repaired using a novel technique, utilizing a semiconductor diode-laser-activated protein solder applied longitudinally across the join. Welding was produced by selective laser denaturation of solid solder bands containing the dye indocyanine green. An in vivo study, using 48 adult male Wistar rats, compared conventional microsuture-repaired tibial nerves with laser solder-repaired nerves. Nerve repairs were characterised immediately after surgery and after 3 months. Successful regeneration with average compound muscle action potentials of 2.5 +/- 0.5 mV and 2.7 +/- 0.3 mV (mean and standard deviation) was demonstrated for the laser-soldered nerves and the sutured nerves, respectively. Histopathology confirmed comparable regeneration of axons in laser- and suture-operated nerves. The laser-based nerve repair technique was easier and faster than microsuture repair, minimising manipulation damage to the nerve.

  9. Quality indexing with computer-aided lexicography

    NASA Technical Reports Server (NTRS)

    Buchan, Ronald L.

    1992-01-01

    Indexing with computers is a far cry from indexing with the first indexing tool, the manual card sorter. With the aid of computer-aided lexicography, both indexing and indexing tools can provide standardization, consistency, and accuracy, resulting in greater quality control than ever before. A brief survey of computer activity in indexing is presented with detailed illustrations from NASA activity. Applications from techniques mentioned, such as Retrospective Indexing (RI), can be made to many indexing systems. In addition to improving the quality of indexing with computers, the improved efficiency with which certain tasks can be done is demonstrated.

  10. α-Glucosidase inhibitory activities of isoflavanones, isoflavones, and pterocarpans from Mucuna pruriens.

    PubMed

    Dendup, Tshewang; Prachyawarakorn, Vilailak; Pansanit, Acharavadee; Mahidol, Chulabhorn; Ruchirawat, Somsak; Kittakoop, Prasat

    2014-05-01

    Three new isoflavanones (1-3) and thirteen known compounds (4-16) were isolated from the roots of Mucuna pruriens. The absolute configurations of isoflavanones 1-3 and parvisoflavanone (4), lespedeol C (5), and uncinanone C (6) were addressed by a circular dichroism technique. Isoflavanones, isoflavones, and pterocarpans of M. pruriens were found to be α-glucosidase inhibitors. Medicarpin (7) and parvisoflavone B (9) were potent α-glucosidase inhibitors (twofold less active than the standard drug acarbose). The production of bioactive metabolites in M. pruriens seems to be season-dependent. Georg Thieme Verlag KG Stuttgart · New York.

  11. Control designs for low-loss active magnetic bearings: Theory and implementation

    NASA Astrophysics Data System (ADS)

    Wilson, Brian Christopher David

    Active Magnetic Bearings (AMB) have been proposed for use in Electromechanical Flywheel Batteries. In these devices, kinetic energy is stored in a magnetically levitated flywheel which spins in a vacuum. The AMB eliminates all mechanical losses, however, electrical loss, which is proportional to the square of the magnetic flux, is still significant. For efficient operation, the flux bias, which is typically introduced into the electromagnets to improve the AMB stiffness, must be reduced, preferably to zero. This zero-bias (ZB) mode of operation cripples the classical control techniques which are customarily used and nonlinear control is required. As a compromise between AMB stiffness and efficiency, a new flux bias scheme is proposed called the generalized complementary flux condition (gcfc). A flux-bias dependent trade-off exists between AMB stiffness, power consumption, and power loss. This work theoretically develops and experimentally verifies new low-loss AMB control designs which employ the gcfc condition. Particular attention is paid to the removal of the singularity present in the standard nonlinear control techniques when operating in ZB. Experimental verification is conduced on a 6-DOF AMB reaction wheel. Practical aspects of the gcfc implementation such as flux measurement and flux-bias implementation with voltage mode amplifiers using IR compensation are investigated. Comparisons are made between the gcfc bias technique and the standard constant-flux-sum (cfs) bias method. Under typical operating circumstances, theoretical analysis and experimental data show that the new gcfc bias scheme is more efficient in producing the control flux required for rotor stabilization than the ordinary cfs bias strategy.

  12. 48 CFR 9905.506-50 - Techniques for application.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... 9905.506-50 Section 9905.506-50 Federal Acquisition Regulations System COST ACCOUNTING STANDARDS BOARD... ACCOUNTING STANDARDS COST ACCOUNTING STANDARDS FOR EDUCATIONAL INSTITUTIONS 9905.506-50 Techniques for application. (a) The cost of an indirect function which exists for only a part of a cost accounting period may...

  13. Technical Note: A 3-D rendering algorithm for electromechanical wave imaging of a beating heart.

    PubMed

    Nauleau, Pierre; Melki, Lea; Wan, Elaine; Konofagou, Elisa

    2017-09-01

    Arrhythmias can be treated by ablating the heart tissue in the regions of abnormal contraction. The current clinical standard provides electroanatomic 3-D maps to visualize the electrical activation and locate the arrhythmogenic sources. However, the procedure is time-consuming and invasive. Electromechanical wave imaging is an ultrasound-based noninvasive technique that can provide 2-D maps of the electromechanical activation of the heart. In order to fully visualize the complex 3-D pattern of activation, several 2-D views are acquired and processed separately. They are then manually registered with a 3-D rendering software to generate a pseudo-3-D map. However, this last step is operator-dependent and time-consuming. This paper presents a method to generate a full 3-D map of the electromechanical activation using multiple 2-D images. Two canine models were considered to illustrate the method: one in normal sinus rhythm and one paced from the lateral region of the heart. Four standard echographic views of each canine heart were acquired. Electromechanical wave imaging was applied to generate four 2-D activation maps of the left ventricle. The radial positions and activation timings of the walls were automatically extracted from those maps. In each slice, from apex to base, these values were interpolated around the circumference to generate a full 3-D map. In both cases, a 3-D activation map and a cine-loop of the propagation of the electromechanical wave were automatically generated. The 3-D map showing the electromechanical activation timings overlaid on realistic anatomy assists with the visualization of the sources of earlier activation (which are potential arrhythmogenic sources). The earliest sources of activation corresponded to the expected ones: septum for the normal rhythm and lateral for the pacing case. The proposed technique provides, automatically, a 3-D electromechanical activation map with a realistic anatomy. This represents a step towards a noninvasive tool to efficiently localize arrhythmias in 3-D. © 2017 American Association of Physicists in Medicine.

  14. 48 CFR 9904.402-50 - Techniques for application.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., OFFICE OF FEDERAL PROCUREMENT POLICY, OFFICE OF MANAGEMENT AND BUDGET PROCUREMENT PRACTICES AND COST ACCOUNTING STANDARDS COST ACCOUNTING STANDARDS 9904.402-50 Techniques for application. (a) The Fundamental...

  15. Sex differences in obesity, dietary habits, and physical activity among urban middle-class Bangladeshis.

    PubMed

    Saquib, Juliann; Saquib, Nazmus; Stefanick, Marcia L; Khanam, Masuma Akter; Anand, Shuchi; Rahman, Mahbubur; Chertow, Glenn M; Barry, Michele; Ahmed, Tahmeed; Cullen, Mark R

    2016-07-01

    The sustained economic growth in Bangladesh during the previous decade has created a substantial middle-class population, who have adequate income to spend on food, clothing, and lifestyle management. Along with the improvements in living standards, has also come negative impact on health for the middle class. The study objective was to assess sex differences in obesity prevalence, diet, and physical activity among urban middle-class Bangladeshi. In this cross-sectional study, conducted in 2012, we randomly selected 402 adults from Mohammedpur, Dhaka. The sampling technique was multi-stage random sampling. We used standardized questionnaires for data collection and measured height, weight, and waist circumference. Mean age (standard deviation) was 49.4 (12.7) years. The prevalence of both generalized (79% vs. 53%) and central obesity (85% vs. 42%) were significantly higher in women than men. Women reported spending more time watching TV and spending less time walking than men (p<.05); however, men reported a higher intake of unhealthy foods such as fast food and soft drinks. We conclude that the prevalence of obesity is significantly higher in urban middle-class Bangladeshis than previous urban estimates, and the burden of obesity disproportionately affects women. Future research and public health efforts are needed to address this severe obesity problem and to promote active lifestyles.

  16. Preparation, spectroscopic and thermal characterization of new charge-transfer complexes of ethidium bromide with π-acceptors. In vitro biological activity studies

    NASA Astrophysics Data System (ADS)

    Eldaroti, Hala H.; Gadir, Suad A.; Refat, Moamen S.; Adam, Abdel Majid A.

    2013-05-01

    Ethidium bromide (EtBr) is a strong DNA binder and has been widely used to probe DNA structure in drug-DNA and protein-DNA interaction. Four new charge-transfer (CT) complexes consisting of EtBr as donor and quinol (QL), picric acid (PA), tetracyanoquinodimethane (TCNQ) or dichlorodicyanobenzoquinone (DDQ) as acceptors, were synthesized and characterized by elemental analysis, electronic absorption, spectrophotometric titration, IR, Raman, 1H NMR and X-ray powder diffraction (XRD) techniques. The stoichiometry of these complexes was found to be 1:2 ratio and having the formula [(EtBr)(acceptor)]. The thermal stability of the synthesized CT complexes was investigated using thermogravimetric (TG) analyses, and the morphology and particle size of these complexes were obtained from scanning electron microscopy (SEM). The CT complexes were also tested for its antibacterial activity against two Gram-positive bacteria Staphylococcus aureus and Bacillus subtilis and two Gram-negative bacteria; Escherichia coli and Pseudomonas aeuroginosa strains by using Tetracycline as standard and antifungal property against Aspergillus flavus and Candida albicans by using amphotericin B as standard. The results were compared with the standard drugs and significant conclusions were obtained. The results indicated that the [(EtBr)(QL)2] complex had exerted excellent inhibitory activity against the growth of the tested bacterial strains.

  17. Screening for antimalarial and acetylcholinesterase inhibitory activities of some Iranian seaweeds

    PubMed Central

    Ghannadi, A; Plubrukarn, A; Zandi, K; Sartavi, K; Yegdaneh, A

    2013-01-01

    Alcoholic extracts of 8 different types of seaweeds from Iran’s Persian Gulf were tested for their antimalarial and acetylcholinesterase enzyme (AChE) inhibitory activities for the first time. A modified Ellman and Ingkaninan method was used for measuring AChE inhibitory activity in which galanthamine was used as the reference. The antimalarial assay was performed using microculture radioisotope technique. Mefloquine and dihydroartemisinin were uased as the standards. The extract of Sargassum boveanum (Sargasseae family) showed the highest AChE inhibitory activity (IC50 equals to 1 mg ml-1) while Cystoseira indica (Cystoseiraceae family) exhibited the least activity (IC50 of 11 mg ml-1). The species from Rhodophyta (Gracilaria corticata and Gracilaria salicornia) also showed moderate activities (IC509.5, 8.7 mg ml-1, respectively). All extracts were inactive in antimalarial assay. PMID:24019820

  18. Statistical Analysis of a Round-Robin Measurement Survey of Two Candidate Materials for a Seebeck Coefficient Standard Reference Material

    PubMed Central

    Lu, Z. Q. J.; Lowhorn, N. D.; Wong-Ng, W.; Zhang, W.; Thomas, E. L.; Otani, M.; Green, M. L.; Tran, T. N.; Caylor, C.; Dilley, N. R.; Downey, A.; Edwards, B.; Elsner, N.; Ghamaty, S.; Hogan, T.; Jie, Q.; Li, Q.; Martin, J.; Nolas, G.; Obara, H.; Sharp, J.; Venkatasubramanian, R.; Willigan, R.; Yang, J.; Tritt, T.

    2009-01-01

    In an effort to develop a Standard Reference Material (SRM™) for Seebeck coefficient, we have conducted a round-robin measurement survey of two candidate materials—undoped Bi2Te3 and Constantan (55 % Cu and 45 % Ni alloy). Measurements were performed in two rounds by twelve laboratories involved in active thermoelectric research using a number of different commercial and custom-built measurement systems and techniques. In this paper we report the detailed statistical analyses on the interlaboratory measurement results and the statistical methodology for analysis of irregularly sampled measurement curves in the interlaboratory study setting. Based on these results, we have selected Bi2Te3 as the prototype standard material. Once available, this SRM will be useful for future interlaboratory data comparison and instrument calibrations. PMID:27504212

  19. Force coordination in static manipulation tasks performed using standard and non-standard grasping techniques.

    PubMed

    de Freitas, Paulo B; Jaric, Slobodan

    2009-04-01

    We evaluated coordination of the hand grip force (GF; normal component of the force acting at the hand-object contact area) and load force (LF; the tangential component) in a variety of grasping techniques and two LF directions. Thirteen participants exerted a continuous sinusoidal LF pattern against externally fixed handles applying both standard (i.e., using either the tips of the digits or the palms; the precision and palm grasps, respectively) and non-standard grasping techniques (using wrists and the dorsal finger areas; the wrist and fist grasp). We hypothesized (1) that the non-standard grasping techniques would provide deteriorated indices of force coordination when compared with the standard ones, and (2) that the nervous system would be able to adjust GF to the differences in friction coefficients of various skin areas used for grasping. However, most of the indices of force coordination remained similar across the tested grasping techniques, while the GF adjustments for the differences in friction coefficients (highest in the palm and the lowest in the fist and wrist grasp) provided inconclusive results. As hypothesized, GF relative to the skin friction was lowest in the precision grasp, but highest in the palm grasp. Therefore, we conclude that (1) the elaborate coordination of GF and LF consistently seen across the standard grasping techniques could be generalized to the non-standard ones, while (2) the ability to adjust GF using the same grasping technique to the differences in friction of various objects cannot be fully generalized to the GF adjustment when different grasps (i.e., hand segments) are used to manipulate the same object. Due to the importance of the studied phenomena for understanding both the functional and neural control aspects of manipulation, future studies should extend the current research to the transient and dynamic tasks, as well as to the general role of friction in our mechanical interactions with the environment.

  20. Deflection-Based Structural Loads Estimation From the Active Aeroelastic Wing F/A-18 Aircraft

    NASA Technical Reports Server (NTRS)

    Lizotte, Andrew M.; Lokos, William A.

    2005-01-01

    Traditional techniques in structural load measurement entail the correlation of a known load with strain-gage output from the individual components of a structure or machine. The use of strain gages has proved successful and is considered the standard approach for load measurement. However, remotely measuring aerodynamic loads using deflection measurement systems to determine aeroelastic deformation as a substitute to strain gages may yield lower testing costs while improving aircraft performance through reduced instrumentation weight. This technique was examined using a reliable strain and structural deformation measurement system. The objective of this study was to explore the utility of a deflection-based load estimation, using the active aeroelastic wing F/A-18 aircraft. Calibration data from ground tests performed on the aircraft were used to derive left wing-root and wing-fold bending-moment and torque load equations based on strain gages, however, for this study, point deflections were used to derive deflection-based load equations. Comparisons between the strain-gage and deflection-based methods are presented. Flight data from the phase-1 active aeroelastic wing flight program were used to validate the deflection-based load estimation method. Flight validation revealed a strong bending-moment correlation and slightly weaker torque correlation. Development of current techniques, and future studies are discussed.

  1. Millimeter-wave signal generation for a wireless transmission system based on on-chip photonic integrated circuit structures.

    PubMed

    Guzmán, R; Carpintero, G; Gordon, C; Orbe, L

    2016-10-15

    We demonstrate and compare two different photonic-based signal sources for generating the carrier wave in a wireless communication link operating in the millimeter-wave range. The first signal source uses the optical heterodyne technique to generate a 113 GHz carrier wave frequency, while the second employs a different technique based on a pulsed mode-locked source with 100 GHz repetition rate frequency. The two optical sources were fabricated in a multi-project wafer run from an active/passive generic integration platform process using standardized building blocks, including multimode interference reflectors which allow us to define the structures on chip, without the need for cleaved facet mirrors. We highlight the superior performance of the mode-locked sources over an optical heterodyne technique. Error-free transmission was achieved in this experiment.

  2. Partial volume correction and image segmentation for accurate measurement of standardized uptake value of grey matter in the brain.

    PubMed

    Bural, Gonca; Torigian, Drew; Basu, Sandip; Houseni, Mohamed; Zhuge, Ying; Rubello, Domenico; Udupa, Jayaram; Alavi, Abass

    2015-12-01

    Our aim was to explore a novel quantitative method [based upon an MRI-based image segmentation that allows actual calculation of grey matter, white matter and cerebrospinal fluid (CSF) volumes] for overcoming the difficulties associated with conventional techniques for measuring actual metabolic activity of the grey matter. We included four patients with normal brain MRI and fluorine-18 fluorodeoxyglucose (F-FDG)-PET scans (two women and two men; mean age 46±14 years) in this analysis. The time interval between the two scans was 0-180 days. We calculated the volumes of grey matter, white matter and CSF by using a novel segmentation technique applied to the MRI images. We measured the mean standardized uptake value (SUV) representing the whole metabolic activity of the brain from the F-FDG-PET images. We also calculated the white matter SUV from the upper transaxial slices (centrum semiovale) of the F-FDG-PET images. The whole brain volume was calculated by summing up the volumes of the white matter, grey matter and CSF. The global cerebral metabolic activity was calculated by multiplying the mean SUV with total brain volume. The whole brain white matter metabolic activity was calculated by multiplying the mean SUV for the white matter by the white matter volume. The global cerebral metabolic activity only reflects those of the grey matter and the white matter, whereas that of the CSF is zero. We subtracted the global white matter metabolic activity from that of the whole brain, resulting in the global grey matter metabolism alone. We then divided the grey matter global metabolic activity by grey matter volume to accurately calculate the SUV for the grey matter alone. The brain volumes ranged between 1546 and 1924 ml. The mean SUV for total brain was 4.8-7. Total metabolic burden of the brain ranged from 5565 to 9617. The mean SUV for white matter was 2.8-4.1. On the basis of these measurements we generated the grey matter SUV, which ranged from 8.1 to 11.3. The accurate metabolic activity of the grey matter can be calculated using the novel segmentation technique that we applied to MRI. By combining these quantitative data with those generated from F-FDG-PET images we were able to calculate the accurate metabolic activity of the grey matter. These types of measurements will be of great value in accurate analysis of the data from patients with neuropsychiatric disorders.

  3. Error estimation in multitemporal InSAR deformation time series, with application to Lanzarote, Canary Islands

    NASA Astrophysics Data System (ADS)

    GonzáLez, Pablo J.; FernáNdez, José

    2011-10-01

    Interferometric Synthetic Aperture Radar (InSAR) is a reliable technique for measuring crustal deformation. However, despite its long application in geophysical problems, its error estimation has been largely overlooked. Currently, the largest problem with InSAR is still the atmospheric propagation errors, which is why multitemporal interferometric techniques have been successfully developed using a series of interferograms. However, none of the standard multitemporal interferometric techniques, namely PS or SB (Persistent Scatterers and Small Baselines, respectively) provide an estimate of their precision. Here, we present a method to compute reliable estimates of the precision of the deformation time series. We implement it for the SB multitemporal interferometric technique (a favorable technique for natural terrains, the most usual target of geophysical applications). We describe the method that uses a properly weighted scheme that allows us to compute estimates for all interferogram pixels, enhanced by a Montecarlo resampling technique that properly propagates the interferogram errors (variance-covariances) into the unknown parameters (estimated errors for the displacements). We apply the multitemporal error estimation method to Lanzarote Island (Canary Islands), where no active magmatic activity has been reported in the last decades. We detect deformation around Timanfaya volcano (lengthening of line-of-sight ˜ subsidence), where the last eruption in 1730-1736 occurred. Deformation closely follows the surface temperature anomalies indicating that magma crystallization (cooling and contraction) of the 300-year shallow magmatic body under Timanfaya volcano is still ongoing.

  4. Intensity and duration of activity bouts decreases in healthy children between 7 and 13 years of age: a new, higher resolution method to analyze StepWatch Activity Monitor data.

    PubMed

    Tulchin-Francis, Kirsten; Stevens, Wilshaw; Jeans, Kelly A

    2014-11-01

    Assessment of physical, ambulatory, activity using accelerometer-based devices has been reported in healthy individuals across a wide range of ages, as well as in multiple patient populations. Many researchers who utilize the StepWatch Activity Monitor (SAM) rely on the default settings for data collection and analysis. A comparison was made between the standard output from the SAM software, and a novel method to evaluate all walking bouts using an Intensity-Duration-Volume (I-D-V) model in healthy children aged 7-13. 105 children without impairment wore the SAM for a total of 1691 d. Statistically significant differences were seen between 7-8-9 year olds and 10-11-12 year olds using the I-D-V model that were not seen using the standard SAM software default output. The increased sensitivity of this technique could be critical for observing the effect of various interventions on patients who experience physical limitations. This new analytical model also allows researchers to monitor activity and exercise-type behavior in a way which coincides with exercise prescription by assessing intensity, duration and volume of activity bouts.

  5. Knudsen Cell Studies of Ti-Al Thermodynamics

    NASA Technical Reports Server (NTRS)

    Jacobson, Nathan S.; Copland, Evan H.; Mehrotra, Gopal M.; Auping, Judith; Gray, Hugh R. (Technical Monitor)

    2002-01-01

    In this paper we describe the Knudsen cell technique for measurement of thermodynamic activities in alloys. Numerous experimental details must be adhered to in order to obtain useful experimental data. These include introduction of an in-situ standard, precise temperature measurement, elimination of thermal gradients, and precise cell positioning. Our first design is discussed and some sample data on Ti-Al alloys is presented. The second modification and associated improvements are also discussed.

  6. Recent Work in Hybrid Radiation Transport Methods with Applications to Commercial Nuclear Power

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kulesza, Joel A.

    This talk will begin with an overview of hybrid radiation transport methods followed by a discussion of the author’s work to advance current capabilities. The talk will then describe applications for these methods in commercial nuclear power reactor analyses and techniques for experimental validation. When discussing these analytical and experimental activities, the importance of technical standards such as those created and maintained by ASTM International will be demonstrated.

  7. Measuring Operational Resilience Using the CERT(Registered) Resilience Management Model

    DTIC Science & Technology

    2010-09-01

    such as ISO 27002 [ ISO 2005]) and then measure the implementation and performance of practices contained in the standard. This checklist-based ap...Security techniques – Code of practice for information security management. ISO /IEC 27002 :2005, June 2005. Also known as ISO /IEC 17799:2005. [ ISO 2007...Table 23: ISO 15939 Process Activities and Tasks 54 Table 24: CERT-RMM Measurement and Analysis Process Area Goals and Practices 55 CMU/SEI

  8. Comparison of anthropometry with photogrammetry based on a standardized clinical photographic technique using a cephalostat and chair.

    PubMed

    Han, Kihwan; Kwon, Hyuk Joon; Choi, Tae Hyun; Kim, Jun Hyung; Son, Daegu

    2010-03-01

    The aim of this study was to standardize clinical photogrammetric techniques, and to compare anthropometry with photogrammetry. To standardize clinical photography, we have developed a photographic cephalostat and chair. We investigated the repeatability of the standardized clinical photogrammetric technique. Then, with 40 landmarks, a total of 96 anthropometric measurement items was obtained from 100 Koreans. Ninety six photogrammetric measurements from the same subjects were also obtained from standardized clinical photographs using Adobe Photoshop version 7.0 (Adobe Systems Corporation, San Jose, CA, USA). The photogrammetric and anthropometric measurement data (mm, degree) were then compared. A coefficient was obtained by dividing the anthropometric measurements by the photogrammetric measurements. The repeatability of the standardized photography was statistically significantly high (p=0.463). Among the 96 measurement items, 44 items were reliable; for these items the photogrammetric measurements were not different to the anthropometric measurements. The remaining 52 items must be classified as unreliable. By developing a photographic cephalostat and chair, we have standardized clinical photogrammetric techniques. The reliable set of measurement items can be used as anthropometric measurements. For unreliable measurement items, applying a suitable coefficient to the photogrammetric measurement allows the anthropometric measurement to be obtained indirectly.

  9. Measuring the radium quartet (228Ra, 226Ra, 224Ra, 223Ra) in seawater samples using gamma spectrometry.

    PubMed

    van Beek, P; Souhaut, M; Reyss, J-L

    2010-07-01

    Radium isotopes are widely used in marine studies (eg. to trace water masses, to quantify mixing processes or to study submarine groundwater discharge). While 228Ra and 226Ra are usually measured using gamma spectrometry, short-lived Ra isotopes (224Ra and 223Ra) are usually measured using a Radium Delayed Coincidence Counter (RaDeCC). Here we show that the four radium isotopes can be analyzed using gamma spectrometry. We report 226Ra, 228Ra, 224Ra, 223Ra activities measured using low-background gamma spectrometry in standard samples, in water samples collected in the vicinity of our laboratory (La Palme and Vaccarès lagoons, France) but also in seawater samples collected in the plume of the Amazon river, off French Guyana (AMANDES project). The 223Ra and 224Ra activities determined in these samples using gamma spectrometry were compared to the activities determined using RaDeCC. Activities determined using the two techniques are in good agreement. Uncertainties associated with the 224Ra activities are similar for the two techniques. RaDeCC is more sensitive for the detection of low 223Ra activities. Gamma spectrometry thus constitutes an alternate method for the determination of short-lived Ra isotopes. 2009 Elsevier Ltd. All rights reserved.

  10. Recommendations for accreditation of laboratories in molecular biology of hematologic malignancies.

    PubMed

    Flandrin-Gresta, Pascale; Cornillet, Pascale; Hayette, Sandrine; Gachard, Nathalie; Tondeur, Sylvie; Mauté, Carole; Cayuela, Jean-Michel

    2015-01-01

    Over recent years, the development of molecular biology techniques has improved the hematological diseases diagnostic and follow-up. Consequently, these techniques are largely used in the biological screening of these diseases; therefore the Hemato-oncology molecular diagnostics laboratories must be actively involved in the accreditation process according the ISO 15189 standard. The French group of molecular biologists (GBMHM) provides requirements for the implementation of quality assurance for the medical molecular laboratories. This guideline states the recommendations for the pre-analytical, analytical (methods validation procedures, quality controls, reagents), and post-analytical conditions. In addition, herein we state a strategy for the internal quality control management. These recommendations will be regularly updated.

  11. Standards for data acquisition and software-based analysis of in vivo electroencephalography recordings from animals. A TASK1-WG5 report of the AES/ILAE Translational Task Force of the ILAE.

    PubMed

    Moyer, Jason T; Gnatkovsky, Vadym; Ono, Tomonori; Otáhal, Jakub; Wagenaar, Joost; Stacey, William C; Noebels, Jeffrey; Ikeda, Akio; Staley, Kevin; de Curtis, Marco; Litt, Brian; Galanopoulou, Aristea S

    2017-11-01

    Electroencephalography (EEG)-the direct recording of the electrical activity of populations of neurons-is a tremendously important tool for diagnosing, treating, and researching epilepsy. Although standard procedures for recording and analyzing human EEG exist and are broadly accepted, there are no such standards for research in animal models of seizures and epilepsy-recording montages, acquisition systems, and processing algorithms may differ substantially among investigators and laboratories. The lack of standard procedures for acquiring and analyzing EEG from animal models of epilepsy hinders the interpretation of experimental results and reduces the ability of the scientific community to efficiently translate new experimental findings into clinical practice. Accordingly, the intention of this report is twofold: (1) to review current techniques for the collection and software-based analysis of neural field recordings in animal models of epilepsy, and (2) to offer pertinent standards and reporting guidelines for this research. Specifically, we review current techniques for signal acquisition, signal conditioning, signal processing, data storage, and data sharing, and include applicable recommendations to standardize collection and reporting. We close with a discussion of challenges and future opportunities, and include a supplemental report of currently available acquisition systems and analysis tools. This work represents a collaboration on behalf of the American Epilepsy Society/International League Against Epilepsy (AES/ILAE) Translational Task Force (TASK1-Workgroup 5), and is part of a larger effort to harmonize video-EEG interpretation and analysis methods across studies using in vivo and in vitro seizure and epilepsy models. Wiley Periodicals, Inc. © 2017 International League Against Epilepsy.

  12. Fibrinolysis standards: a review of the current status.

    PubMed

    Thelwell, C

    2010-07-01

    Biological standards are used to calibrate measurements of components of the fibrinolytic system, either for assigning potency values to therapeutic products, or to determine levels in human plasma as an indicator of thrombotic risk. Traditionally WHO International Standards are calibrated in International Units based on consensus values from collaborative studies. The International Unit is defined by the response activity of a given amount of the standard in a bioassay, independent of the method used. Assay validity is based on the assumption that both standard and test preparation contain the same analyte, and the response in an assay is a true function of this analyte. This principle is reflected in the diversity of source materials used to prepare fibrinolysis standards, which has depended on the contemporary preparations they were employed to measure. With advancing recombinant technology, and improved analytical techniques, a reference system based on reference materials and associated reference methods has been recommended for future fibrinolysis standards. Careful consideration and scientific judgement must however be applied when deciding on an approach to develop a new standard, with decisions based on the suitability of a standard to serve its purpose, and not just to satisfy a metrological ideal. 2010 The International Association for Biologicals. Published by Elsevier Ltd. All rights reserved.

  13. The Effects of Magnetic Activity on Lithium-Inferred Ages of Stars

    NASA Astrophysics Data System (ADS)

    Juarez, Aaron J.; Cargile, Phillip A.; James, David J.; Stassun, Keivan G.

    2014-08-01

    In this project, we investigate the effects of magnetic activity on the Lithium Depletion Boundary (LDB) to recalibrate the measured ages for star clusters, using the open cluster Blanco 1 as a pilot study. We apply the LDB technique on low-mass Pre-Main-Sequence (PMS) stars to derive an accurate age for Blanco 1, and we consider the effect of magnetic activity on this inferred age. Although observations have shown that magnetic activity directly affects stellar radius and temperature, most PMS models do not include the effects of magnetic activity on stellar properties. Since the lithium abundance of a star depends on its radius and temperature, we expect that LDB ages are affected by magnetic activity. After empirically accounting for the effects of magnetic activity, we find the age of Blanco 1 to be ~100 Myr, which is ~30 Myr younger than the standard LDB age of ~130 Myr.

  14. Does Angling Technique Selectively Target Fishes Based on Their Behavioural Type?

    PubMed Central

    Wilson, Alexander D. M.; Brownscombe, Jacob W.; Sullivan, Brittany; Jain-Schlaepfer, Sofia; Cooke, Steven J.

    2015-01-01

    Recently, there has been growing recognition that fish harvesting practices can have important impacts on the phenotypic distributions and diversity of natural populations through a phenomenon known as fisheries-induced evolution. Here we experimentally show that two common recreational angling techniques (active crank baits versus passive soft plastics) differentially target wild largemouth bass (Micropterus salmoides) and rock bass (Ambloplites rupestris) based on variation in their behavioural tendencies. Fish were first angled in the wild using both techniques and then brought back to the laboratory and tested for individual-level differences in common estimates of personality (refuge emergence, flight-initiation-distance, latency-to-recapture and with a net, and general activity) in an in-lake experimental arena. We found that different angling techniques appear to selectively target these species based on their boldness (as characterized by refuge emergence, a standard measure of boldness in fishes) but not other assays of personality. We also observed that body size was independently a significant predictor of personality in both species, though this varied between traits and species. Our results suggest a context-dependency for vulnerability to capture relative to behaviour in these fish species. Ascertaining the selective pressures angling practices exert on natural populations is an important area of fisheries research with significant implications for ecology, evolution, and resource management. PMID:26284779

  15. Standard versus Rotation Technique for Insertion of Supraglottic Airway Devices: Systematic Review and Meta-Analysis

    PubMed Central

    Park, Jin Ha; Lee, Jong Seok; Nam, Sang Beom; Ju, Jin Wu

    2016-01-01

    Purpose Supraglottic airway devices have been widely utilized as an alternative to tracheal intubation in various clinical situations. The rotation technique has been proposed to improve the insertion success rate of supraglottic airways. However, the clinical efficacy of this technique remains uncertain as previous results have been inconsistent, depending on the variable evaluated. Materials and Methods We systematically searched PubMed, Embase, and the Cochrane Central Register of Controlled Trials in April 2015 for randomized controlled trials that compared the rotation and standard techniques for inserting supraglottic airways. Results Thirteen randomized controlled trials (1505 patients, 753 with the rotation technique) were included. The success rate at the first attempt was significantly higher with the rotation technique than with the standard technique [relative risk (RR): 1.13; 95% confidence interval (CI): 1.05 to 1.23; p=0.002]. The rotation technique provided significantly higher overall success rates (RR: 1.06; 95% CI: 1.04 to 1.09; p<0.001). Device insertion was completed faster with the rotation technique (mean difference: -4.6 seconds; 95% CI: -7.37 to -1.74; p=0.002). The incidence of blood staining on the removed device (RR: 0.36; 95% CI: 0.27 to 0.47; p<0.001) was significantly lower with the rotation technique. Conclusion The rotation technique provided higher first-attempt and overall success rates, faster insertion, and a lower incidence of blood on the removed device, reflecting less mucosal trauma. Thus, it may be considered as an alternative to the standard technique when predicting or encountering difficulty in inserting supraglottic airways. PMID:27189296

  16. SDVSRM - a new SSRM based technique featuring dynamically adjusted, scanner synchronized sample voltages for measurement of actively operated devices.

    PubMed

    Doering, Stefan; Wachowiak, Andre; Roetz, Hagen; Eckl, Stefan; Mikolajick, Thomas

    2018-06-01

    Scanning spreading resistance microscopy (SSRM) with its high spatial resolution and high dynamic signal range is a powerful tool for two-dimensional characterization of semiconductor dopant areas. However, the application of the method is limited to devices in equilibrium condition, as the investigation of actively operated devices would imply potential differences within the device, whereas SSRM relies on a constant voltage difference between sample surface and probe tip. Furthermore, the standard preparation includes short circuiting of all device components, limiting applications to devices in equilibrium condition. In this work scanning dynamic voltage spreading resistance microscopy (SDVSRM), a new SSRM based two pass atomic force microscopy (AFM) technique is introduced, overcoming these limitations. Instead of short circuiting the samples during preparation, wire bond devices are used allowing for active control of the individual device components. SDVSRM consists of two passes. In the first pass the local sample surface voltage dependent on the dc biases applied to the components of the actively driven device is measured as in scanning voltage microscopy (SVM). The local spreading resistance is measured within the second pass, in which the afore obtained local surface voltage is used to dynamically adjust the terminal voltages of the device under test. This is done in a way that the local potential difference across the nano-electrical contact matches the software set SSRM measurement voltage, and at the same time, the internal voltage differences within the device under test are maintained. In this work the proof of the concept could be demonstrated by obtaining spreading resistance data of an actively driven photodiode test device. SDVSRM adds a higher level of flexibility in general to SSRM, as occurring differences in cross section surface voltage are taken into account. These differences are immanent for actively driven devices, but can also be present at standard, short circuited samples. Therefore, SDVSRM could improve the characterization under equilibrium conditions as well. Copyright © 2018. Published by Elsevier B.V.

  17. Blood venous sample collection: Recommendations overview and a checklist to improve quality.

    PubMed

    Giavarina, Davide; Lippi, Giuseppe

    2017-07-01

    The extra-analytical phases of the total testing process have substantial impact on managed care, as well as an inherent high risk of vulnerability to errors which is often greater than that of the analytical phase. The collection of biological samples is a crucial preanalytical activity. Problems or errors occurring shortly before, or soon after, this preanalytical step may impair sample quality and characteristics, or else modify the final results of testing. The standardization of fasting requirements, rest, patient position and psychological state of the patient are therefore crucial for mitigating the impact of preanalytical variability. Moreover, the quality of materials used for collecting specimens, along with their compatibility, can guarantee sample quality and persistence of chemical and physical characteristics of the analytes over time, so safeguarding the reliability of testing. Appropriate techniques and sampling procedures are effective to prevent problems such as hemolysis, undue clotting in the blood tube, draw of insufficient sample volume and modification of analyte concentration. An accurate identification of both patient and blood samples is a key priority as for other healthcare activities. Good laboratory practice and appropriate training of operators, by specifically targeting collection of biological samples, blood in particular, may greatly improve this issue, thus lowering the risk of errors and their adverse clinical consequences. The implementation of a simple and rapid check-list, including verification of blood collection devices, patient preparation and sampling techniques, was found to be effective for enhancing sample quality and reducing some preanalytical errors associated with these procedures. The use of this tool, along with implementation of objective and standardized systems for detecting non-conformities related to unsuitable samples, can be helpful for standardizing preanalytical activities and improving the quality of laboratory diagnostics, ultimately helping to reaffirm a "preanalytical" culture founded on knowledge and real risk perception. Copyright © 2017 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  18. A rapid method for estimation of Pu-isotopes in urine samples using high volume centrifuge.

    PubMed

    Kumar, Ranjeet; Rao, D D; Dubla, Rupali; Yadav, J R

    2017-07-01

    The conventional radio-analytical technique used for estimation of Pu-isotopes in urine samples involves anion exchange/TEVA column separation followed by alpha spectrometry. This sequence of analysis consumes nearly 3-4 days for completion. Many a times excreta analysis results are required urgently, particularly under repeat and incidental/emergency situations. Therefore, there is need to reduce the analysis time for the estimation of Pu-isotopes in bioassay samples. This paper gives the details of standardization of a rapid method for estimation of Pu-isotopes in urine samples using multi-purpose centrifuge, TEVA resin followed by alpha spectrometry. The rapid method involves oxidation of urine samples, co-precipitation of plutonium along with calcium phosphate followed by sample preparation using high volume centrifuge and separation of Pu using TEVA resin. Pu-fraction was electrodeposited and activity estimated using 236 Pu tracer recovery by alpha spectrometry. Ten routine urine samples of radiation workers were analyzed and consistent radiochemical tracer recovery was obtained in the range 47-88% with a mean and standard deviation of 64.4% and 11.3% respectively. With this newly standardized technique, the whole analytical procedure is completed within 9h (one working day hour). Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Clinical safety and effectiveness of transversus abdominis plane (TAP) block in post-operative analgesia: a systematic review and meta-analysis.

    PubMed

    Ma, Ning; Duncan, Joanna K; Scarfe, Anje J; Schuhmann, Susanne; Cameron, Alun L

    2017-06-01

    Transversus abdominis plane (TAP) blocks can provide analgesia postoperatively for a range of surgeries. Abundant clinical trials have assessed TAP block showing positive analgesic effects. This systematic review assesses safety and effectiveness outcomes of TAP block in all clinical settings, comparing with both active (standard care) and inactive (placebo) comparators. PubMed, EMBASE, The Cochrane Library and the University of York CRD databases were searched. RCTs were screened for their eligibility and assessed for risk of bias. Meta-analyses were performed on available data. TAP block showed an equivalent safety profile to all comparators in the incidence of nausea (OR = 1.07) and vomiting (OR = 0.81). TAP block was more effective in reducing morphine consumption [MD = 13.05, 95% CI (8.33, 51.23)] and in delaying time to first analgesic request [MD = 123.49, 95% CI (48.59, 198.39)]. Postoperative pain within 24 h was reduced or at least equivalent in TAP block compared to its comparators. Therefore, TAP block is a safe and effective procedure compared to standard care, placebo and other analgesic techniques. Further research is warranted to investigate whether the TAP block technique can be improved by optimizing dose and technique-related factors.

  20. PyMVPA: A python toolbox for multivariate pattern analysis of fMRI data.

    PubMed

    Hanke, Michael; Halchenko, Yaroslav O; Sederberg, Per B; Hanson, Stephen José; Haxby, James V; Pollmann, Stefan

    2009-01-01

    Decoding patterns of neural activity onto cognitive states is one of the central goals of functional brain imaging. Standard univariate fMRI analysis methods, which correlate cognitive and perceptual function with the blood oxygenation-level dependent (BOLD) signal, have proven successful in identifying anatomical regions based on signal increases during cognitive and perceptual tasks. Recently, researchers have begun to explore new multivariate techniques that have proven to be more flexible, more reliable, and more sensitive than standard univariate analysis. Drawing on the field of statistical learning theory, these new classifier-based analysis techniques possess explanatory power that could provide new insights into the functional properties of the brain. However, unlike the wealth of software packages for univariate analyses, there are few packages that facilitate multivariate pattern classification analyses of fMRI data. Here we introduce a Python-based, cross-platform, and open-source software toolbox, called PyMVPA, for the application of classifier-based analysis techniques to fMRI datasets. PyMVPA makes use of Python's ability to access libraries written in a large variety of programming languages and computing environments to interface with the wealth of existing machine learning packages. We present the framework in this paper and provide illustrative examples on its usage, features, and programmability.

  1. PyMVPA: A Python toolbox for multivariate pattern analysis of fMRI data

    PubMed Central

    Hanke, Michael; Halchenko, Yaroslav O.; Sederberg, Per B.; Hanson, Stephen José; Haxby, James V.; Pollmann, Stefan

    2009-01-01

    Decoding patterns of neural activity onto cognitive states is one of the central goals of functional brain imaging. Standard univariate fMRI analysis methods, which correlate cognitive and perceptual function with the blood oxygenation-level dependent (BOLD) signal, have proven successful in identifying anatomical regions based on signal increases during cognitive and perceptual tasks. Recently, researchers have begun to explore new multivariate techniques that have proven to be more flexible, more reliable, and more sensitive than standard univariate analysis. Drawing on the field of statistical learning theory, these new classifier-based analysis techniques possess explanatory power that could provide new insights into the functional properties of the brain. However, unlike the wealth of software packages for univariate analyses, there are few packages that facilitate multivariate pattern classification analyses of fMRI data. Here we introduce a Python-based, cross-platform, and open-source software toolbox, called PyMVPA, for the application of classifier-based analysis techniques to fMRI datasets. PyMVPA makes use of Python's ability to access libraries written in a large variety of programming languages and computing environments to interface with the wealth of existing machine-learning packages. We present the framework in this paper and provide illustrative examples on its usage, features, and programmability. PMID:19184561

  2. Thunderstorm incidence in southeastern Brazil estimated from different data sources

    NASA Astrophysics Data System (ADS)

    Pinto, O., Jr.; Naccarato, K. P.; Pinto, I. R. C. A.

    2013-07-01

    This paper describes a comparative analysis of the thunderstorm incidence in southeastern Brazil obtained from thunderstorm days observed at two different epochs (from 1910 to 1951 and from 1971 to 1984) and from lightning data provided by the Brazilian lightning location system RINDAT (from 1999 to 2006) and the Lightning Imaging Sensor (LIS) on board the Tropical Rainfall Measuring Mission (TRMM) satellite (from 1998 to 2010). The results are interpreted in terms of the main synoptic patterns associated with thunderstorm activity in this region, indicating that the prevailing synoptic pattern associated with thunderstorm activity is the occurrence of frontal systems and their modulation by the South Atlantic Convergence Zone (SACZ) and topography. Evidence of urban effects is also found. The results are also discussed in the context of practical applications involving their use in the Brazilian lightning protection standards, suggesting that the present version of the Brazilian standards should be revised incorporating RINDAT and LIS data. Finally, the results are important to improve our knowledge about the limitations of the different techniques used to record the thunderstorm activity and support future climatic studies.

  3. Physical and biological properties of U. S. standard endotoxin EC after exposure to ionizing radiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Csako, G.; Elin, R.J.; Hochstein, H.D.

    Techniques that reduce the toxicity of bacterial endotoxins are useful for studying the relationship between structure and biological activity. We used ionizing radiation to detoxify a highly refined endotoxin preparation. U.S. standard endotoxin EC. Dose-dependent changes occurred by exposure to /sup 60/Co-radiation in the physical properties and biological activities of the endotoxin. Sodium dodecyl sulfate-polyacrylamide slab gel electrophoresis showed gradual loss of the polysaccharide components (O-side chain and R-core) from the endotoxin molecules. In contrast, although endotoxin revealed a complex absorption pattern in the UV range, radiation treatment failed to modify that pattern. Dose-related destruction of the primary toxic component,more » lipid A, was suggested by the results of activity tests: both the pyrogenicity and limulus reactivity of the endotoxin were destroyed by increasing doses of radiation. The results indicate that the detoxification is probably due to multiple effects of the ionizing radiation on bacterial lipopolysaccharides, and the action involves (i) the destruction of polysaccharide moieties and possibly (ii) the alteration of lipid A component of the endotoxin molecule.« less

  4. Practical semen analysis: from A to Z

    PubMed Central

    Brazil, Charlene

    2010-01-01

    Accurate semen analysis is critical for decisions about patient care, as well as for studies addressing overall changes in semen quality, contraceptive efficacy and effects of toxicant exposure. The standardization of semen analysis is very difficult for many reasons, including the use of subjective techniques with no standards for comparison, poor technician training, problems with proficiency testing and a reluctance to change techniques. The World Health Organization (WHO) Semen handbook (2010) offers a vastly improved set of standardized procedures, all at a level of detail that will preclude most misinterpretations. However, there is a limit to what can be learned from words and pictures alone. A WHO-produced DVD that offers complete demonstrations of each technique along with quality assurance standards for motility, morphology and concentration assessments would enhance the effectiveness of the manual. However, neither the manual nor a DVD will help unless there is general acknowledgement of the critical need to standardize techniques and rigorously pursue quality control to ensure that laboratories actually perform techniques 'according to WHO' instead of merely reporting that they have done so. Unless improvements are made, patient results will continue to be compromised and comparison between studies and laboratories will have limited merit. PMID:20111076

  5. CMMI(Registered) for Acquisition, Version 1.3. CMMI-ACQ, V1.3

    DTIC Science & Technology

    2010-11-01

    and Software Engineering – System Life Cycle Processes [ ISO 2008b] ISO /IEC 27001 :2005 Information technology – Security techniques – Information...International Organization for Standardization and International Electrotechnical Commission. ISO /IEC 27001 Information Technology – Security Techniques...International Organization for Standardization/International Electrotechnical Commission ( ISO /IEC) body of standards. CMMs focus on improving processes

  6. ACETYL CHOLINESTERASE AND BUTYRYL CHOLINESTERASE INhIBITORY ACTIVITIES OF ZALEYA PENTANDRA.

    PubMed

    Afzal, Samina; Chaudhry, Bashir Ahmad; Afzal, Khurram; Saeed, Javeria; Akash, Sajd Hamid; Qadir, Muhammad Imran

    2017-05-01

    The aim of this study was to reveal acetyl cholinesterase (AchE) and butyryl cholinesterase (BchE) inhibitory activities of Zaleya pentandra. The aerial parts of the plant were air, freeze-dried and powdered. The extraction was carried out with methanol at room temperature for 24 h. The extract was concentrated on rotavapor and fractioned by column chromatography. The isolation and purification afforded amorphous solid which was subjected to physical, chemical and spectroscopic techniques i.e., UV, IR, H-NMR, "C-NMR and HREI-MS for the structure elucidation of the isolated compound. The compound was concluded as "Pentandradione" a novel compound. AchE and BchE inhibitory activities were estimated. The result showed that the isolated extract possessed significant activity against butyryl cholinesterase as compared to standard eserine while the extract lacks acetyl cholinesterase inhibitory activity.

  7. Student profiling on university co-curricular activities using cluster analysis

    NASA Astrophysics Data System (ADS)

    Rajenthran, Hemabegai A./P.; Shaharanee, Izwan Nizal Mohd; Jamil, Jastini Mohd.

    2017-11-01

    In higher learning institutions, the co-curricular programs are needed for the graduation besides the standard academic programs. By actively participating in co-curricular, students can attain many of soft skills and proficiencies besides learning and adopting campus environment, community and traditions. Co-curricular activities are implemented by universities mainly for the refinement of the academic achievement along with the social development. This studies aimed to analyse the academic profile of the co-curricular students among uniform units. The main objective of study is to develop a profile of student co-curricular activities in uniform units. Additionally, several variables has been selected to serve as the characteristics for student co-curricular profile. The findings of this study demonstrate the practicality of clustering technique to investigate student's profiles and allow for a better understanding of student's behavior and co-curriculum activities.

  8. Laser frequency stabilization and control through offset sideband locking to optical cavities.

    PubMed

    Thorpe, J I; Numata, K; Livas, J

    2008-09-29

    We describe a class of techniques whereby a laser frequency can be stabilized to a fixed optical cavity resonance with an adjustable offset, providing a wide tuning range for the central frequency. These techniques require only minor modifications to the standard Pound-Drever-Hall locking techniques and have the advantage of not altering the intrinsic stability of the frequency reference. We discuss the expected performance and limitations of these techniques and present a laboratory investigation in which both the sideband techniques and the standard, on-tunable Pound-Drever- Hall technique reached the 100Hz/square root(Hz) level.

  9. Multi-Quadrant Biopsy Technique Improves Diagnostic Ability in Large Heterogeneous Renal Masses.

    PubMed

    Abel, E Jason; Heckman, Jennifer E; Hinshaw, Louis; Best, Sara; Lubner, Meghan; Jarrard, David F; Downs, Tracy M; Nakada, Stephen Y; Lee, Fred T; Huang, Wei; Ziemlewicz, Timothy

    2015-10-01

    Percutaneous biopsy obtained from a single location is prone to sampling error in large heterogeneous renal masses, leading to nondiagnostic results or failure to detect poor prognostic features. We evaluated the accuracy of percutaneous biopsy for large renal masses using a modified multi-quadrant technique vs a standard biopsy technique. Clinical and pathological data for all patients with cT2 or greater renal masses who underwent percutaneous biopsy from 2009 to 2014 were reviewed. The multi-quadrant technique was defined as multiple core biopsies from at least 4 separate solid enhancing areas in the tumor. The incidence of nondiagnostic findings, sarcomatoid features and procedural complications was recorded, and concordance between biopsy specimens and nephrectomy pathology was compared. A total of 122 biopsies were performed for 117 tumors in 116 patients (46 using the standard biopsy technique and 76 using the multi-quadrant technique). Median tumor size was 10 cm (IQR 8-12). Biopsy was nondiagnostic in 5 of 46 (10.9%) standard and 0 of 76 (0%) multi-quadrant biopsies (p=0.007). Renal cell carcinoma was identified in 96 of 115 (82.0%) tumors and nonrenal cell carcinoma tumors were identified in 21 (18.0%). One complication occurred using the standard biopsy technique and no complications were reported using the multi-quadrant technique. Sarcomatoid features were present in 23 of 96 (23.9%) large renal cell carcinomas studied. Sensitivity for identifying sarcomatoid features was higher using the multi-quadrant technique compared to the standard biopsy technique at 13 of 15 (86.7%) vs 2 of 8 (25.0%) (p=0.0062). The multi-quadrant percutaneous biopsy technique increases the ability to identify aggressive pathological features in large renal tumors and decreases nondiagnostic biopsy rates. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  10. Emergency cricothyrotomy-a comparative study of different techniques in human cadavers.

    PubMed

    Schober, Patrick; Hegemann, Martina C; Schwarte, Lothar A; Loer, Stephan A; Noetges, Peter

    2009-02-01

    Emergency cricothyrotomy is the final lifesaving option in "cannot intubate-cannot ventilate" situations. Fast, efficient and safe management is indispensable to reestablish oxygenation, thus the quickest, most reliable and safest technique should be used. Several cricothyrotomy techniques exist, which can be grouped into two categories: anatomical-surgical and puncture. We studied success rate, tracheal tube insertion time and complications of different techniques, including a novel cricothyrotomy scissors technique in human cadavers. Sixty-three inexperienced health care providers were randomly assigned to apply either an anatomical-surgical technique (standard surgical technique, n=18; novel cricothyrotomy scissors technique, n=14) or a puncture technique (catheter-over-needle technique, n=17; wire-guided technique, n=14). Airway access was almost always successful with the anatomical-surgical techniques (success rate in standard surgical group 94%, scissors group 100%). In contrast, the success rate was smaller (p<0.05) with the puncture techniques (catheter-over-needle group 82%, wire-guided technique 71%). Tracheal tube insertion time was faster overall (p<0.05) with anatomical-surgical techniques (standard surgical 78s [54-135], novel cricothyrotomy scissors technique 60s [42-82]; median [IQR]) than with puncture techniques (catheter-over-needle technique 74s [48-145], wire-guided technique 135s [116-307]). We observed fewer complications with anatomical-surgical techniques than with puncture techniques (p<0.001). In inexperienced health care personnel, anatomical-surgical techniques showed a higher success rate, a faster tracheal tube insertion time and a lower complication rate compared with puncture techniques, suggesting that they may be the techniques of choice in emergencies.

  11. [Evaluation of the total biological activity and allergenic composition of allergenic extracts].

    PubMed

    Lombardero, M; González, R; Duffort, O; Juan, F; Ayuso, R; Ventas, P; Cortés, C; Carreira, J

    1986-01-01

    In the present study, a complete procedure is presented in order to standardize allergenic extracts, the meaning of which is the measurement of the total allergenic activity and the determination of the allergenic composition. The measurement of the biological activity comprises 2 steps: Preparation of Reference Extracts and determination of their "in vivo" activity. Evaluation of the total allergenic activity of extracts for clinical use. Reference extracts were prepared from the main allergens and their "in vivo" biological activity was determined by a quantitative skin prick test in a sample of at least 30 allergic patients. By definition, the protein concentration of Reference Extract that produces, in the allergic population, a geometric mean wheal of 75 mm.2 has an activity of 100 biological units (BUs). The determination of the biological activity of a problem extract is made by RAST inhibition. The sample is compared with the corresponding Reference Extract by this technique and, from this comparison, it is possible to quantify the activity of the problem extract in biologic units (BUs) with clinical significance. Likewise, different techniques have been used to determine the allergenic composition of extracts. These techniques comprise 2 steps: Separation of the components of the extract. Identification of the components that bind specific human IgE. The separation of the components of the extract has been carried out by isoelectric focusing (IEF) and electrophoresis in the presence of sodium dodecyl sulphate (SDS-PAGE). In order to identify the allergenic components, an immunoblotting technique has been employed. The separated components in the IEF gel or SDS-PAGE gel are transferred to a nitrocellulose sheet and later on, this membrane is overlaid with a serum pool from allergic patients and a mouse monoclonal anti-human IgE, labelled with 125I. Finally, the autoradiography of the nitrocellulose membrane is obtained. In this way it is possible to compare the allergenic composition of an extract with the corresponding Reference Extract and so to employ for clinical use only those extracts with the right allergenic composition.

  12. How do laboratory embryo transfer techniques affect IVF outcomes? A review of current literature.

    PubMed

    Sigalos, George; Triantafyllidou, Olga; Vlahos, Nikos

    2017-04-01

    Over the last few years, many studies have focused on embryo selection methods, whereas little attention has been given to the standardization of the procedure of embryo transfer. In this review, several parameters of the embryo transfer procedure are examined, such as the: (i) culture medium volume and loading technique; (ii) syringe and catheters used for embryo transfer; (iii) viscosity and composition of the embryo transfer medium; (iv) environment of embryo culture; (v) timing of embryo transfer; (vi) and standardization of the embryo transfer techniques. The aim of this manuscript is to review these factors and compare the existing embryo transfer techniques and highlight the need for better embryo transfer standardization.

  13. A prospective, observational study comparing the PK/PD relationships of generic Meropenem (Mercide®) to the innovator brand in critically ill patients

    PubMed Central

    Mer, Mervyn; Snyman, Jacques Rene; van Rensburg, Constance Elizabeth Jansen; van Tonder, Jacob John; Laurens, Ilze

    2016-01-01

    Introduction Clinicians’ skepticism, fueled by evidence of inferiority of some multisource generic antimicrobial products, results in the underutilization of more cost-effective generics, especially in critically ill patients. The aim of this observational study was to demonstrate equivalence between the generic or comparator brand of meropenem (Mercide®) and the leading innovator brand (Meronem®) by means of an ex vivo technique whereby antimicrobial activity is used to estimate plasma concentration of the active moiety. Methods Patients from different high care and intensive care units were recruited for observation when prescribed either of the meropenem brands under investigation. Blood samples were collected over 6 hours after a 30 minute infusion of the different brands. Meropenem concentration curves were established against United States Pharmacopeia standard meropenem (Sigma-Aldrich) by using standard laboratory techniques for culture of Klebsiella pneumoniae. Patients’ plasma samples were tested ex vivo, using a disc diffusion assay, to confirm antimicrobial activity and estimate plasma concentrations of the two brands. Results Both brands of meropenem demonstrated similar curves in donor plasma when concentrations in vials were confirmed. Patient-specific serum concentrations were determined from zones of inhibition against a standard laboratory Klebsiella strain ex vivo, confirming at least similar in vivo concentrations as the concentration curves (90% confidence interval) overlapped; however, the upper limit of the area under the curve for the ratio comparator/innovator exceeded the 1.25-point estimate, i.e., 4% higher for comparator meropenem. Conclusion This observational, in-practice study demonstrates similar ex vivo activity and in vivo plasma concentration time curves for the products under observation. Assay sensitivity is also confirmed. Current registration status of generic small molecules is in place. The products are therefore clinically interchangeable based on registration status as well as bioassay results, demonstrating sufficient overlap for clinical comfort. The slightly higher observed comparator meropenem concentration (4%) is still clinically acceptable due to the large therapeutic index and should ally fears of inferiority. PMID:27895516

  14. NASA Handbook for Models and Simulations: An Implementation Guide for NASA-STD-7009

    NASA Technical Reports Server (NTRS)

    Steele, Martin J.

    2013-01-01

    The purpose of this Handbook is to provide technical information, clarification, examples, processes, and techniques to help institute good modeling and simulation practices in the National Aeronautics and Space Administration (NASA). As a companion guide to NASA-STD- 7009, Standard for Models and Simulations, this Handbook provides a broader scope of information than may be included in a Standard and promotes good practices in the production, use, and consumption of NASA modeling and simulation products. NASA-STD-7009 specifies what a modeling and simulation activity shall or should do (in the requirements) but does not prescribe how the requirements are to be met, which varies with the specific engineering discipline, or who is responsible for complying with the requirements, which depends on the size and type of project. A guidance document, which is not constrained by the requirements of a Standard, is better suited to address these additional aspects and provide necessary clarification. This Handbook stems from the Space Shuttle Columbia Accident Investigation (2003), which called for Agency-wide improvements in the "development, documentation, and operation of models and simulations"' that subsequently elicited additional guidance from the NASA Office of the Chief Engineer to include "a standard method to assess the credibility of the models and simulations."2 General methods applicable across the broad spectrum of model and simulation (M&S) disciplines were sought to help guide the modeling and simulation processes within NASA and to provide for consistent reporting ofM&S activities and analysis results. From this, the standardized process for the M&S activity was developed. The major contents of this Handbook are the implementation details of the general M&S requirements ofNASA-STD-7009, including explanations, examples, and suggestions for improving the credibility assessment of an M&S-based analysis.

  15. The Effect of Long-Term Therapeutics, Prophylaxis and Screening Techniques on Aircrew Medical Standards.

    DTIC Science & Technology

    1981-03-01

    percentage of fat , maximal aerobic power, serum concentrations of triglycerides, total cholesterol and HDL cholesterol. This information is obtained fr-m each...drinkinq and physical activity related to health parameters su-h as wei ,iht , body fat content, maximal aerobic T1ewer and serum concentrations of...subjects, and the body fat is estimated from the body density (4). 3. The maximal aerobic power is assessed indirectly according to the method of Astrand

  16. Walking on four limbs: A systematic review of Nordic Walking in Parkinson disease.

    PubMed

    Bombieri, Federica; Schena, Federico; Pellegrini, Barbara; Barone, Paolo; Tinazzi, Michele; Erro, Roberto

    2017-05-01

    Nordic Walking is a relatively high intensity activity that is becoming increasingly popular. It involves marching using poles adapted from cross-country skiing poles in order to activate upper body muscles that would not be used during normal walking. Several studies have been performed using this technique in Parkinson disease patients with contradictory results. Thus, we reviewed here all studies using this technique in Parkinson disease patients and further performed a meta-analysis of RCTs where Nordic Walking was evaluated against standard medical care or other types of physical exercise. Nine studies including four RCTs were reviewed for a total of 127 patients who were assigned to the Nordic Walking program. The majority of studies reported beneficial effects of Nordic Walking on either motor or non-motor variables, but many limitations were observed that hamper drawing definitive conclusions and it is largely unclear whether the benefits persist over time. It would appear that little baseline disability is the strongest predictor of response. The meta-analysis of the 4 RCTs yielded a statistically significant reduction of the UPDRS-3 score, but its value of less than 1 point does not appear to be clinically meaningful. Well-designed, large RCTs should be performed both against standard medical care and other types of physical exercise to definitively address whether Nordic Walking can be beneficial in PD. Copyright © 2017. Published by Elsevier Ltd.

  17. Thromboelastography platelet mapping in healthy dogs using 1 analyzer versus 2 analyzers.

    PubMed

    Blois, Shauna L; Banerjee, Amrita; Wood, R Darren; Park, Fiona M

    2013-07-01

    The objective of this study was to describe the results of thromboelastography platelet mapping (TEG-PM) carried out using 2 techniques in 20 healthy dogs. Maximum amplitudes (MA) generated by thrombin (MAthrombin), fibrin (MAfibrin), adenosine diphosphate (ADP) receptor activity (MAADP), and thromboxane A2 (TxA2) receptor activity (stimulated by arachidonic acid, MAAA) were recorded. Thromboelastography platelet mapping was carried out according to the manufacturer's guidelines (2-analyzer technique) and using a variation of this method employing only 1 analyzer (1-analyzer technique) on 2 separate blood samples obtained from each dog. Mean [± standard deviation (SD)] MA values for the 1-analyzer/2-analyzer techniques were: MAthrombin = 51.9 mm (± 7.1)/52.5 mm (± 8.0); MAfibrin = 20.7 mm (± 21.8)/23.0 mm (± 26.1); MAADP = 44.5 mm (± 15.6)/45.6 mm (± 17.0); and MAAA = 45.7 mm (± 11.6)/45.0 mm (± 15.4). Mean (± SD) percentage aggregation due to ADP receptor activity was 70.4% (± 32.8)/67.6% (± 33.7). Mean percentage aggregation due to TxA2 receptor activity was 77.3% (± 31.6)/78.1% (± 50.2). Results of TEG-PM were not significantly different for the 1-analyzer and 2-analyzer methods. High correlation was found between the 2 methods for MAfibrin [concordance correlation coefficient (r) = 0.930]; moderate correlation was found for MAthrombin (r = 0.70) and MAADP (r = 0.57); correlation between the 2 methods for MAAA was lower (r = 0.32). Thromboelastography platelet mapping (TEG-PM) should be further investigated to determine if it is a suitable method for measuring platelet dysfunction in dogs with thrombopathy.

  18. Thromboelastography platelet mapping in healthy dogs using 1 analyzer versus 2 analyzers

    PubMed Central

    Blois, Shauna L.; Banerjee, Amrita; Wood, R. Darren; Park, Fiona M.

    2013-01-01

    The objective of this study was to describe the results of thromboelastography platelet mapping (TEG-PM) carried out using 2 techniques in 20 healthy dogs. Maximum amplitudes (MA) generated by thrombin (MAthrombin), fibrin (MAfibrin), adenosine diphosphate (ADP) receptor activity (MAADP), and thromboxane A2 (TxA2) receptor activity (stimulated by arachidonic acid, MAAA) were recorded. Thromboelastography platelet mapping was carried out according to the manufacturer’s guidelines (2-analyzer technique) and using a variation of this method employing only 1 analyzer (1-analyzer technique) on 2 separate blood samples obtained from each dog. Mean [± standard deviation (SD)] MA values for the 1-analyzer/2-analyzer techniques were: MAthrombin = 51.9 mm (± 7.1)/52.5 mm (± 8.0); MAfibrin = 20.7 mm (± 21.8)/23.0 mm (± 26.1); MAADP = 44.5 mm (± 15.6)/45.6 mm (± 17.0); and MAAA = 45.7 mm (± 11.6)/45.0 mm (± 15.4). Mean (± SD) percentage aggregation due to ADP receptor activity was 70.4% (± 32.8)/67.6% (± 33.7). Mean percentage aggregation due to TxA2 receptor activity was 77.3% (± 31.6)/78.1% (± 50.2). Results of TEG-PM were not significantly different for the 1-analyzer and 2-analyzer methods. High correlation was found between the 2 methods for MAfibrin [concordance correlation coefficient (r) = 0.930]; moderate correlation was found for MAthrombin (r = 0.70) and MAADP (r = 0.57); correlation between the 2 methods for MAAA was lower (r = 0.32). Thromboelastography platelet mapping (TEG-PM) should be further investigated to determine if it is a suitable method for measuring platelet dysfunction in dogs with thrombopathy. PMID:24101802

  19. Simulations of motor unit number estimation techniques

    NASA Astrophysics Data System (ADS)

    Major, Lora A.; Jones, Kelvin E.

    2005-06-01

    Motor unit number estimation (MUNE) is an electrodiagnostic procedure used to evaluate the number of motor axons connected to a muscle. All MUNE techniques rely on assumptions that must be fulfilled to produce a valid estimate. As there is no gold standard to compare the MUNE techniques against, we have developed a model of the relevant neuromuscular physiology and have used this model to simulate various MUNE techniques. The model allows for a quantitative analysis of candidate MUNE techniques that will hopefully contribute to consensus regarding a standard procedure for performing MUNE.

  20. Standardization of proton-induced x-ray emission technique for analysis of thick samples

    NASA Astrophysics Data System (ADS)

    Ali, Shad; Zeb, Johar; Ahad, Abdul; Ahmad, Ishfaq; Haneef, M.; Akbar, Jehan

    2015-09-01

    This paper describes the standardization of the proton-induced x-ray emission (PIXE) technique for finding the elemental composition of thick samples. For the standardization, three different samples of standard reference materials (SRMs) were analyzed using this technique and the data were compared with the already known data of these certified SRMs. These samples were selected in order to cover the maximum range of elements in the periodic table. Each sample was irradiated for three different values of collected beam charges at three different times. A proton beam of 2.57 MeV obtained using 5UDH-II Pelletron accelerator was used for excitation of x-rays from the sample. The acquired experimental data were analyzed using the GUPIXWIN software. The results show that the SRM data and the data obtained using the PIXE technique are in good agreement.

  1. Correlating laser-induced breakdown spectroscopy with neutron activation analysis to determine the elemental concentration in the ionome of the Populus trichocarpa leaf

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, Madhavi Z.; Glasgow, David C.; Tschaplinski, Timothy J.

    The black cottonwood poplar (Populus trichocarpa) leaf ionome (inorganic trace elements and mineral nutrients) is an important aspect for determining the physiological and developmental processes contributing to biomass production. A number of techniques are used to measure the ionome, yet characterizing the leaf spatial heterogeneity remains a challenge, especially in solid samples. Laser-induced breakdown spectroscopy (LIBS) has been used to determine the elemental composition of leaves and is able to raster across solid matrixes at 10 μm resolution. Here, we evaluate the use of LIBS for solid sample leaf elemental characterization in relation to neutron activation. In fact, neutron activationmore » analysis is a laboratory-based technique which is used by the National Institute of Standards and Technology (NIST) to certify trace elements in candidate reference materials including plant leaf matrices. Introduction to the techniques used in this research has been presented in this manuscript. Neutron activation analysis (NAA) data has been correlated to the LIBS spectra to achieve quantification of the elements or ions present within poplar leaves. The regression coefficients of calibration and validation using multivariate analysis (MVA) methodology for six out of seven elements have been determined and vary between 0.810 and 0.998. LIBS and NAA data has been presented for the elements such as, calcium, magnesium, manganese, aluminum, copper, and potassium. Chlorine was also detected but it did not show good correlation between the LIBS and NAA techniques. This research shows that LIBS can be used as a fast, high-spatial resolution technique to quantify elements as part of large-scale field phenotyping projects.« less

  2. Correlating laser-induced breakdown spectroscopy with neutron activation analysis to determine the elemental concentration in the ionome of the Populus trichocarpa leaf

    DOE PAGES

    Martin, Madhavi Z.; Glasgow, David C.; Tschaplinski, Timothy J.; ...

    2017-10-17

    The black cottonwood poplar (Populus trichocarpa) leaf ionome (inorganic trace elements and mineral nutrients) is an important aspect for determining the physiological and developmental processes contributing to biomass production. A number of techniques are used to measure the ionome, yet characterizing the leaf spatial heterogeneity remains a challenge, especially in solid samples. Laser-induced breakdown spectroscopy (LIBS) has been used to determine the elemental composition of leaves and is able to raster across solid matrixes at 10 μm resolution. Here, we evaluate the use of LIBS for solid sample leaf elemental characterization in relation to neutron activation. In fact, neutron activationmore » analysis is a laboratory-based technique which is used by the National Institute of Standards and Technology (NIST) to certify trace elements in candidate reference materials including plant leaf matrices. Introduction to the techniques used in this research has been presented in this manuscript. Neutron activation analysis (NAA) data has been correlated to the LIBS spectra to achieve quantification of the elements or ions present within poplar leaves. The regression coefficients of calibration and validation using multivariate analysis (MVA) methodology for six out of seven elements have been determined and vary between 0.810 and 0.998. LIBS and NAA data has been presented for the elements such as, calcium, magnesium, manganese, aluminum, copper, and potassium. Chlorine was also detected but it did not show good correlation between the LIBS and NAA techniques. This research shows that LIBS can be used as a fast, high-spatial resolution technique to quantify elements as part of large-scale field phenotyping projects.« less

  3. Arthroplasty for Unreconstructable Acute Fractures and Failed Fracture Fixation About the Hip and Knee in the Active Elderly: A New Paradigm.

    PubMed

    Kyle, Richard F; Duwelius, Paul J; Haidukewych, George J; Schmidt, Andrew H

    2017-02-15

    The techniques, materials, and designs for total joint arthroplasty underwent major improvements in the past 30 years. During this time, trauma surgeons classified the severity of fractures as well as identified certain articular fractures that do not have good outcomes and have a high rate of failure after internal fixation. Advanced improvements in arthroplasty have increased its reliability and longevity. Total joint arthroplasty is becoming a standard of care for some acute articular fractures, particularly displaced femoral neck fractures in the active elderly. Total joint arthroplasty also has become the standard of care after failed internal fixation in patients who have very complicated fractures about the knee, hip, and shoulder. As the population ages, fractures worldwide continue to rapidly increase. Elderly patients have a high risk for fractures that result from falls because of their poor bone quality. The current active elderly population participates in higher risk activities than previous elderly populations, which places them at risk for more injuries. This has become both a worldwide healthcare problem and an economic problem. Surgeons need to manage fractures in the active elderly with the latest advancements in technology and patient selection to ensure rapid recovery and the reduction of complications.

  4. Antarctica as a Martian model.

    NASA Technical Reports Server (NTRS)

    Vishniac, W. V.; Mainzer, S. E.

    1973-01-01

    Results of a survey of a variety of environments in the dry valleys of Antarctica, ranging from mountain crests to valley floors. The main purpose of the investigation was the determination of active microbial multiplication in the soil. A series of techniques was employed which permitted the detection of bacterial growth in situ. All evidence points to an active growth of micro-organisms in the Antarctic soil in all locations examined. The measurements were supported by electron micrographs of soil films which showed colonial growth covering soil particles. These findings suggest that Antarctica does not serve as a useful model for the Martian environment in evaluating quarantine standards.

  5. Oleic Acid Produced by a Marine Vibrio spp. Acts as an Anti-Vibrio parahaemolyticus Agent

    PubMed Central

    Leyton, Yanett; Borquez, Jorge; Darias, José; Cueto, Mercedes; Díaz-Marrero, Ana R.; Riquelme, Carlos

    2011-01-01

    It is known that some strains of Vibrio parahaemolyticus are responsible for gastroenteric diseases caused by the ingestion of marine organisms contaminated with these bacterial strains. Organic products that show inhibitory activity on the growth of the pathogenic V. parahaemolyticus were extracted from a Vibrio native in the north of Chile. The inhibitory organic products were isolated by reverse phase chromatography and permeation by Sephadex LH20, and were characterized by spectroscopic and spectrometric techniques. The results showed that the prevailing active product is oleic acid, which was compared with standards by gas chromatography and high-performance liquid chromatography (HPLC). These active products might be useful for controlling the proliferation of pathogenic clones of V. parahaemolyticus. PMID:22073014

  6. Active Learning and Cooperative Learning in the Organic Chemistry Lecture Class

    NASA Astrophysics Data System (ADS)

    Paulson, Donald R.

    1999-08-01

    Faculty in the physical sciences are one of the academic groups least receptive to the use of active learning strategies and cooperative learning in their classrooms. This is particularly so in traditional lecture classes. It is the objective of this paper to show how effective these techniques can be in improving student performance in classes. The use of active learning strategies and cooperative learning groups in my organic chemistry lecture classes has increased the overall pass rate in my classes by an astounding 20-30% over the traditional lecture mode. This has been accomplished without any reduction in "standards". The actual methods employed are presented as well as a discussion of how I came to radically change the way I teach my classes.

  7. Thiadiazole derivatives as New Class of β-glucuronidase inhibitors.

    PubMed

    Salar, Uzma; Taha, Muhammad; Ismail, Nor Hadiani; Khan, Khalid Mohammed; Imran, Syahrul; Perveen, Shahnaz; Wadood, Abdul; Riaz, Muhammad

    2016-04-15

    Thiadiazole derivatives 1-24 were synthesized via a single step reaction and screened for in vitro β-glucuronidase inhibitory activity. All the synthetic compounds displayed good inhibitory activity in the range of IC50=2.16 ± 0.01-58.06 ± 1.60 μM as compare to standard d-saccharic acid 1,4-lactone (IC50=48.4 ± 1.25 μM). Molecular docking study was conducted in order to establish the structure-activity relationship (SAR) which demonstrated that thiadiazole as well as both aryl moieties (aryl and N-aryl) involved to exhibit the inhibitory potential. All the synthetic compounds were characterized by spectroscopic techniques (1)H, (13)C NMR, and EIMS. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Alteration of hairpin ribozyme specificity utilizing PCR.

    PubMed

    DeGrandis, P; Hampel, A; Galasinski, S; Borneman, J; Siwkowski, A; Altschuler, M

    1994-12-01

    We have developed a method by which a researcher can quickly alter the specificity of a trans hairpin ribozyme. Utilizing this PCR method, two oligonucleotides, and any target vector, new ribozyme template sequences can be generated without the synthesis of longer oligonucleotides. We have produced templates with altered specificity for both standard and modified (larger) ribozymes. After transcription, these ribozymes show specific cleavage activity with the new substrate beta-glucuronidase (GUS), and no activity against the original substrate (HIV-1, 5' leader sequence). Utilizing this technique, it is also possible to produce an inactive ribozyme that can be used as an antisense control. Applications of this procedure would provide a rapid and economical system for the assessment of trans ribozyme activity.

  9. Practical synthesis, anticonvulsant, and antimicrobial activity of N-allyl and N-propargyl di(indolyl)indolin-2-ones.

    PubMed

    Praveen, Chandrasekaran; Ayyanar, Asairajan; Perumal, Paramasivan Thirumalai

    2011-07-01

    An operation friendly protocol for the synthesis of novel di(indolyl)indolin-2-ones via Cu(OTf)(2) catalyzed bis-addition of N-allyl and N-propargyl indole with isatin was developed. This methodology allowed us to achieve the products in excellent yields without requiring purification technique like column chromatography. All the synthesized compounds were evaluated for their in vivo anticonvulsant activity against maximal electroshock test. Six compounds showed maximum activity compared to the standard drug phenytoin. The scope of the new molecules as antimicrobial agents were tested against two bacterial strains (Staphylococcus aureus and Escherichia coli) and one fungal strain (Candida albicans). Copyright © 2011 Elsevier Ltd. All rights reserved.

  10. One-calibrant kinetic calibration for on-site water sampling with solid-phase microextraction.

    PubMed

    Ouyang, Gangfeng; Cui, Shufen; Qin, Zhipei; Pawliszyn, Janusz

    2009-07-15

    The existing solid-phase microextraction (SPME) kinetic calibration technique, using the desorption of the preloaded standards to calibrate the extraction of the analytes, requires that the physicochemical properties of the standard should be similar to those of the analyte, which limited the application of the technique. In this study, a new method, termed the one-calibrant kinetic calibration technique, which can use the desorption of a single standard to calibrate all extracted analytes, was proposed. The theoretical considerations were validated by passive water sampling in laboratory and rapid water sampling in the field. To mimic the variety of the environment, such as temperature, turbulence, and the concentration of the analytes, the flow-through system for the generation of standard aqueous polycyclic aromatic hydrocarbons (PAHs) solution was modified. The experimental results of the passive samplings in the flow-through system illustrated that the effect of the environmental variables was successfully compensated with the kinetic calibration technique, and all extracted analytes can be calibrated through the desorption of a single calibrant. On-site water sampling with rotated SPME fibers also illustrated the feasibility of the new technique for rapid on-site sampling of hydrophobic organic pollutants in water. This technique will accelerate the application of the kinetic calibration method and also will be useful for other microextraction techniques.

  11. A dosimetric study of cardiac dose sparing using the reverse semi-decubitus technique for left breast and internal mammary chain irradiation.

    PubMed

    Niglas, Mark; McCann, Claire; Keller, Brian M; Makhani, Nadiya; Presutti, Joseph; Vesprini, Danny; Rakovitch, Eileen; Elzibak, Alyaa; Mashouf, Shahram; Lee, Justin

    2016-01-01

    Breath-hold techniques can reduce cardiac dose in breast radiotherapy. The reverse semi-decubitus (RSD) technique is an alternative free-breathing method used at our centre. This study compares the dosimetry of free-breathing supine, RSD and moderate deep inspiration breath-hold (mDIBH) techniques. Twelve patients with left-sided breast cancer who were simulated using standard supine, RSD and mDIBH techniques were identified retrospectively. New plans using standard breast tangents and techniques for internal mammary chain (IMC) nodal coverage were assessed. Using standard tangents, mean heart dose, heart V25Gy and mean left anterior descending artery (LAD) dose were found to be significantly lower for RSD and mDIBH when compared to free-breathing supine (p ⩽ 0.03). Using wide-tangents, the maximum LAD point dose was also lower for RSD and mDIBH (p ⩽ 0.02). There were no statistically significant dosimetric differences found between the RSD and mDIBH simulation techniques for standard breast-tangent plans, though organ-at-risk doses were lower for mDIBH in wide-tangent plans. There was no improvement in cardiac dosimetry between RSD and free-breathing supine when using an electron field IMC plan. For patients unable to tolerate breath-hold, the RSD technique is an alternative approach that can reduce cardiac dose. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. Fifty years of solid-phase extraction in water analysis--historical development and overview.

    PubMed

    Liska, I

    2000-07-14

    The use of an appropriate sample handling technique is a must in an analysis of organic micropollutants in water. The efforts to use a solid phase for the recovery of analytes from a water matrix prior to their detection have a long history. Since the first experimental trials using activated carbon filters that were performed 50 years ago, solid-phase extraction (SPE) has become an established sample preparation technique. The initial experimental applications of SPE resulted in widespread use of this technique in current water analysis and also to adoption of SPE into standardized analytical methods. During the decades of its evolution, chromatographers became aware of the advantages of SPE and, despite many innovations that appeared in the last decade, new SPE developments are still expected in the future. A brief overview of 50 years of the history of the use of SPE in organic trace analysis of water is given in presented paper.

  13. Spatial analysis of plutonium-239 + 240 and Americium-241 in soils around Rocky Flats, Colorado

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Litaor, M.I.

    1995-05-01

    Plutonium and american contamination of soils around Rocky Flats, Colorado resulted from past outdoor storage practices. Four previous studies produce four different Pu isopleth maps. Spatial estimation techniques were not used in the construction of these maps and were also based on an extremely small number of soil samples. The purpose of this study was to elucidate the magnitude of Pu-239 + 240 and Am-241 dispersion in the soil environment east of Rocky Flats using robust spatial estimation techniques. Soils were sampled from 118 plots of 1.01 and 4.05 ha by compositing 25 evenly spaced samples in each plot frommore » the top 0.64 cm. Plutonium-239 + 240 activity ranged from 1.85 to 53 560 Bq/kg with a mean of 1924 Bq/kg and a standard deviation of 6327 Bq/kg. Americium-241 activity ranged from 0.18 to 9990 Bq/kg with a mean of 321 Bq/kg and a standard deviation of 1143 Bq/kg. Geostatistical techniques were used to model the spatial dependency and construct isopleth maps showing Pu-239 + 240 and Am-241 distribution. The isopleth configuration was consistent with the hypothesis that the dominant dispersal mechanism of Pu-239 + 240 was wind dispersion from west to east. The Pu-239 + 240 isopleth map proposed to this study differed significantly in the direction and distance of dispersal from the previously published maps. This ispleth map as well as the Am-241 map should be used as the primary data for future risk assessment associated with public exposure to Pu-239 + 240 and Am-241. 37 refs., 7 figs., 2 tabs.« less

  14. PATTERN PRACTICE IN THE TEACHING OF STANDARD ENGLISH TO STUDENTS WITH A NON-STANDARD DIALECT.

    ERIC Educational Resources Information Center

    LIN, SAN-SU C.

    THE EXTENT TO WHICH PATTERN PRACTICE TECHNIQUES HELPED NEGRO STUDENTS WHO NEEDED TO MASTER STANDARD ENGLISH AS A SECOND LANGUAGE WAS INVESTIGATED. MATERIALS AND PROCEDURES TO IMPLEMENT SUCH TECHNIQUES WERE WORKED OUT. THE SUBJECTS ATTENDED CLAFLIN COLLEGE, AN ALL-NEGRO 4-YEAR COLLEGE IN SOUTH CAROLINA. APPROXIMATELY 65 TO 70 FRESHMEN WERE PLACED…

  15. Double row equivalent for rotator cuff repair: A biomechanical analysis of a new technique.

    PubMed

    Robinson, Sean; Krigbaum, Henry; Kramer, Jon; Purviance, Connor; Parrish, Robin; Donahue, Joseph

    2018-06-01

    There are numerous configurations of double row fixation for rotator cuff tears however, there remains to be a consensus on the best method. In this study, we evaluated three different double-row configurations, including a new method. Our primary question is whether the new anchor and technique compares in biomechanical strength to standard double row techniques. Eighteen prepared fresh frozen bovine infraspinatus tendons were randomized to one of three groups including the New Double Row Equivalent, Arthrex Speedbridge and a transosseous equivalent using standard Stabilynx anchors. Biomechanical testing was performed on humeri sawbones and ultimate load, strain, yield strength, contact area, contact pressure, and a survival plots were evaluated. The new double row equivalent method demonstrated increased survival as well as ultimate strength at 415N compared to the remainder testing groups as well as equivalent contact area and pressure to standard double row techniques. This new anchor system and technique demonstrated higher survival rates and loads to failure than standard double row techniques. This data provides us with a new method of rotator cuff fixation which should be further evaluated in the clinical setting. Basic science biomechanical study.

  16. Intra-operative multi-site stimulation: Expanding methodology for cortical brain mapping of language functions

    PubMed Central

    Korn, Akiva; Kirschner, Adi; Perry, Daniella; Hendler, Talma; Ram, Zvi

    2017-01-01

    Direct cortical stimulation (DCS) is considered the gold-standard for functional cortical mapping during awake surgery for brain tumor resection. DCS is performed by stimulating one local cortical area at a time. We present a feasibility study using an intra-operative technique aimed at improving our ability to map brain functions which rely on activity in distributed cortical regions. Following standard DCS, Multi-Site Stimulation (MSS) was performed in 15 patients by applying simultaneous cortical stimulations at multiple locations. Language functioning was chosen as a case-cognitive domain due to its relatively well-known cortical organization. MSS, performed at sites that did not produce disruption when applied in a single stimulation point, revealed additional language dysfunction in 73% of the patients. Functional regions identified by this technique were presumed to be significant to language circuitry and were spared during surgery. No new neurological deficits were observed in any of the patients following surgery. Though the neuro-electrical effects of MSS need further investigation, this feasibility study may provide a first step towards sophistication of intra-operative cortical mapping. PMID:28700619

  17. Modulation theory, dispersive shock waves and Gerald Beresford Whitham

    NASA Astrophysics Data System (ADS)

    Minzoni, A. A.; Smyth, Noel F.

    2016-10-01

    Gerald Beresford (GB) Whitham, FRS, (13th December, 1927-26th January, 2014) was one of the leading applied mathematicians of the twentieth century whose work over forty years had a profound, formative impact on research on wave motion across a broad range of areas. Many of the ideas and techniques he developed have now become the standard tools used to analyse and understand wave motion, as the papers of this special issue of Physica D testify. Many of the techniques pioneered by GB Whitham have spread beyond wave propagation into other applied mathematics areas, such as reaction-diffusion, and even into theoretical physics and pure mathematics, in which Whitham modulation theory is an active area of research. GB Whitham's classic textbook Linear and Nonlinear Waves, published in 1974, is still the standard reference for the applied mathematics of wave motion. In honour of his scientific achievements, GB Whitham was elected a Fellow of the American Academy of Arts and Sciences in 1959 and a Fellow of the Royal Society in 1965. He was awarded the Norbert Wiener Prize for Applied Mathematics in 1980.

  18. Intra-operative multi-site stimulation: Expanding methodology for cortical brain mapping of language functions.

    PubMed

    Gonen, Tal; Gazit, Tomer; Korn, Akiva; Kirschner, Adi; Perry, Daniella; Hendler, Talma; Ram, Zvi

    2017-01-01

    Direct cortical stimulation (DCS) is considered the gold-standard for functional cortical mapping during awake surgery for brain tumor resection. DCS is performed by stimulating one local cortical area at a time. We present a feasibility study using an intra-operative technique aimed at improving our ability to map brain functions which rely on activity in distributed cortical regions. Following standard DCS, Multi-Site Stimulation (MSS) was performed in 15 patients by applying simultaneous cortical stimulations at multiple locations. Language functioning was chosen as a case-cognitive domain due to its relatively well-known cortical organization. MSS, performed at sites that did not produce disruption when applied in a single stimulation point, revealed additional language dysfunction in 73% of the patients. Functional regions identified by this technique were presumed to be significant to language circuitry and were spared during surgery. No new neurological deficits were observed in any of the patients following surgery. Though the neuro-electrical effects of MSS need further investigation, this feasibility study may provide a first step towards sophistication of intra-operative cortical mapping.

  19. A Single-Block TRL Test Fixture for the Cryogenic Characterization of Planar Microwave Components

    NASA Technical Reports Server (NTRS)

    Mejia, M.; Creason, A. S.; Toncich, S. S.; Ebihara, B. T.; Miranda, F. A.

    1996-01-01

    The High-Temperature-Superconductivity (HTS) group of the RF Technology Branch, Space Electronics Division, is actively involved in the fabrication and cryogenic characterization of planar microwave components for space applications. This process requires fast, reliable, and accurate measurement techniques not readily available. A new calibration standard/test fixture that enhances the integrity and reliability of the component characterization process has been developed. The fixture consists of 50 omega thru, reflect, delay, and device under test gold lines etched onto a 254 microns (0.010 in) thick alumina substrate. The Thru-Reflect-Line (TRL) fixture was tested at room temperature using a 30 omega, 7.62 mm (300 mil) long, gold line as a known standard. Good agreement between the experimental data and the data modelled using Sonnet's em(C) software was obtained for both the return (S(sub 11)) and insertion (S( 21)) losses. A gold two-pole bandpass filter with a 7.3 GHz center frequency was used as our Device Under Test (DUT), and the results compared with those obtained using a Short-Open-Load-Thru (SOLT) calibration technique.

  20. Improved recovery of functionally active eosinophils and neutrophils using novel immunomagnetic technology.

    PubMed

    Son, Kiho; Mukherjee, Manali; McIntyre, Brendan A S; Eguez, Jose C; Radford, Katherine; LaVigne, Nicola; Ethier, Caroline; Davoine, Francis; Janssen, Luke; Lacy, Paige; Nair, Parameswaran

    2017-10-01

    Clinically relevant and reliable reports derived from in vitro research are dependent on the choice of cell isolation protocols adopted between different laboratories. Peripheral blood eosinophils are conventionally isolated using density-gradient centrifugation followed by immunomagnetic selection (positive/negative) while neutrophils follow a more simplified dextran-sedimentation methodology. With the increasing sophistication of molecular techniques, methods are now available that promise protocols with reduced user-manipulations, improved efficiency, and better yield without compromising the purity of enriched cell populations. These recent techniques utilize immunomagnetic particles with multiple specificities against differential cell surface markers to negatively select non-target cells from whole blood, greatly reducing the cost/time taken to isolate granulocytes. Herein, we compare the yield efficiencies, purity and baseline activation states of eosinophils/neutrophils isolated using one of these newer protocols that use immunomagnetic beads (MACSxpress isolation) vs. the standard isolation procedures. The study shows that the MACSxpress method consistently allowed higher yields per mL of peripheral blood compared to conventional methods (P<0.001, n=8, Wilcoxon paired test), with high isolation purities for both eosinophils (95.0±1.7%) and neutrophils (94.2±10.1%) assessed by two methods: Wright's staining and flow cytometry. In addition, enumeration of CD63 + (marker for eosinophil activation) and CD66b + (marker for neutrophil activation) cells within freshly isolated granulocytes, respectively, confirmed that conventional protocols using density-gradient centrifugation caused cellular activation of the granulocytes at baseline compared to the MACSxpress method. In conclusion, MACSxpress isolation kits were found to be superior to conventional techniques for consistent purifications of eosinophils and neutrophils that were suitable for activation assays involving degranulation markers. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. The frequency and time standard and activities at the Beijing Institute of Radio Metrology and Measurements. [China

    NASA Technical Reports Server (NTRS)

    Wang, H. T.

    1979-01-01

    Three kinds of frequency measuring systems are described: frequency comparison, phase comparison, and time comparison. With the help of the portable cesium clock in determining the time delay between two stations, a time synchronization, experiment was conducted using the Symphonie satellite. A result with an accuracy of 30 ns and an uncertainty of about 10 ns was obtained. Another experiment, applying the television pulse technique for time synchronization, yielded a result with an error of about 0.5 mu s in 24 hours. In order to measure the short term frequency stability of crystal oscillators or other frequency sources, a rubidium maser atomic frequency standard was developed as well as a short term stability measuring system.

  2. An array processing system for lunar geochemical and geophysical data

    NASA Technical Reports Server (NTRS)

    Eliason, E. M.; Soderblom, L. A.

    1977-01-01

    A computerized array processing system has been developed to reduce, analyze, display, and correlate a large number of orbital and earth-based geochemical, geophysical, and geological measurements of the moon on a global scale. The system supports the activities of a consortium of about 30 lunar scientists involved in data synthesis studies. The system was modeled after standard digital image-processing techniques but differs in that processing is performed with floating point precision rather than integer precision. Because of flexibility in floating-point image processing, a series of techniques that are impossible or cumbersome in conventional integer processing were developed to perform optimum interpolation and smoothing of data. Recently color maps of about 25 lunar geophysical and geochemical variables have been generated.

  3. Bone biosensors: knowing the present and predicting the future

    NASA Astrophysics Data System (ADS)

    Khashayar, Patricia; Amoabediny, Ghassem; Larijani, Bagher; Vanfleteren, Jan

    2016-02-01

    Bone is an active organ with the capacity of continuous remodeling throughout adult life. In view of the fact that the current gold standard to assess bone remodeling, bone mineral density, suffers from certain limitations, newer techniques are being developed. Currently enzyme-linked immunosorbent assay is commonly used to assess bone turnover markers; the technique, however, is expensive, time consuming and needs trained personnel. Thus, there is a growing demand to fabricate different types of biosensors to provide low cost miniaturized platforms to assess the bone remodeling process more accurately. This review focuses on the latest advancements in the field of bone biosensing technologies. Its results might help provide possible solutions for translation of this technology for point-of-care diagnostic applications.

  4. Thermal imaging of plasma with a phased array antenna in QUEST

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mishra, Kishore, E-mail: mishra@triam.kyushu-u.ac.jp; Nagata, K.; Akimoto, R.

    2014-11-15

    A thermal imaging system to measure plasma Electron Bernstein Emission (EBE) emanating from the mode conversion region in overdense plasma is discussed. Unlike conventional ECE/EBE imaging, this diagnostics does not employ any active mechanical scanning mirrors or focusing optics to scan for the emission cones in plasma. Instead, a standard 3 × 3 waveguide array antenna is used as a passive receiver to collect emission from plasma and imaging reconstruction is done by accurate measurements of phase and intensity of these signals by heterodyne detection technique. A broadband noise source simulating the EBE, is installed near the expected mode conversionmore » region and its position is successfully reconstructed using phase array technique which is done in post processing.« less

  5. Tracking speech comprehension in space and time.

    PubMed

    Pulvermüller, Friedemann; Shtyrov, Yury; Ilmoniemi, Risto J; Marslen-Wilson, William D

    2006-07-01

    A fundamental challenge for the cognitive neuroscience of language is to capture the spatio-temporal patterns of brain activity that underlie critical functional components of the language comprehension process. We combine here psycholinguistic analysis, whole-head magnetoencephalography (MEG), the Mismatch Negativity (MMN) paradigm, and state-of-the-art source localization techniques (Equivalent Current Dipole and L1 Minimum-Norm Current Estimates) to locate the process of spoken word recognition at a specific moment in space and time. The magnetic MMN to words presented as rare "deviant stimuli" in an oddball paradigm among repetitive "standard" speech stimuli, peaked 100-150 ms after the information in the acoustic input, was sufficient for word recognition. The latency with which words were recognized corresponded to that of an MMN source in the left superior temporal cortex. There was a significant correlation (r = 0.7) of latency measures of word recognition in individual study participants with the latency of the activity peak of the superior temporal source. These results demonstrate a correspondence between the behaviorally determined recognition point for spoken words and the cortical activation in left posterior superior temporal areas. Both the MMN calculated in the classic manner, obtained by subtracting standard from deviant stimulus response recorded in the same experiment, and the identity MMN (iMMN), defined as the difference between the neuromagnetic responses to the same stimulus presented as standard and deviant stimulus, showed the same significant correlation with word recognition processes.

  6. Sex differences in obesity, dietary habits, and physical activity among urban middle-class Bangladeshis

    PubMed Central

    Saquib, Juliann; Saquib, Nazmus; Stefanick, Marcia L.; Khanam, Masuma Akter; Anand, Shuchi; Rahman, Mahbubur; Chertow, Glenn M.; Barry, Michele; Ahmed, Tahmeed; Cullen, Mark R.

    2016-01-01

    Background The sustained economic growth in Bangladesh during the previous decade has created a substantial middle-class population, who have adequate income to spend on food, clothing, and lifestyle management. Along with the improvements in living standards, has also come negative impact on health for the middle class. The study objective was to assess sex differences in obesity prevalence, diet, and physical activity among urban middle-class Bangladeshi. Methods In this cross-sectional study, conducted in 2012, we randomly selected 402 adults from Mohammedpur, Dhaka. The sampling technique was multi-stage random sampling. We used standardized questionnaires for data collection and measured height, weight, and waist circumference. Results Mean age (standard deviation) was 49.4 (12.7) years. The prevalence of both generalized (79% vs. 53%) and central obesity (85% vs. 42%) were significantly higher in women than men. Women reported spending more time watching TV and spending less time walking than men (p<.05); however, men reported a higher intake of unhealthy foods such as fast food and soft drinks. Conclusions We conclude that the prevalence of obesity is significantly higher in urban middle-class Bangladeshis than previous urban estimates, and the burden of obesity disproportionately affects women. Future research and public health efforts are needed to address this severe obesity problem and to promote active lifestyles. PMID:27610059

  7. Recording event-related activity under hostile magnetic resonance environment: Is multimodal EEG/ERP-MRI recording possible?

    PubMed

    Karakaş, H M; Karakaş, S; Ozkan Ceylan, A; Tali, E T

    2009-08-01

    Event-related potentials (ERPs) have high temporal resolution, but insufficient spatial resolution; the converse is true for the functional imaging techniques. The purpose of the study was to test the utility of a multimodal EEG/ERP-MRI technique which combines electroencephalography (EEG) and magnetic resonance imaging (MRI) for a simultaneously high temporal and spatial resolution. The sample consisted of 32 healthy young adults of both sexes. Auditory stimuli were delivered according to the active and passive oddball paradigms in the MRI environment (MRI-e) and in the standard conditions of the electrophysiology laboratory environment (Lab-e). Tasks were presented in a fixed order. Participants were exposed to the recording environments in a counterbalanced order. EEG data were preprocessed for MRI-related artifacts. Source localization was made using a current density reconstruction technique. The ERP waveforms for the MRI-e were morphologically similar to those for the Lab-e. The effect of the recording environment, experimental paradigm and electrode location were analyzed using a 2x2x3 analysis of variance for repeated measures. The ERP components in the two environments showed parametric variations and characteristic topographical distributions. The calculated sources were in line with the related literature. The findings indicated effortful cognitive processing in MRI-e. The study provided preliminary data on the feasibility of the multimodal EEG/ERP-MRI technique. It also indicated lines of research that are to be pursued for a decisive testing of this technique and its implementation to clinical practice.

  8. A Tape Method for Fast Characterization and Identification of Active Pharmaceutical Ingredients in the 2-18 THz Spectral Range

    NASA Astrophysics Data System (ADS)

    Kissi, Eric Ofosu; Bawuah, Prince; Silfsten, Pertti; Peiponen, Kai-Erik

    2015-03-01

    In order to find counterfeit drugs quickly and reliably, we have developed `tape method' a transmission spectroscopic terahertz (THz) measurement technique and compared it with a standard attenuated total reflection (ATR) THz spectroscopic measurement. We used well-known training samples, which include commercial paracetamol and aspirin tablets to check the validity of these two measurement techniques. In this study, the spectral features of some active pharmaceutical ingredients (APIs), such as aspirin and paracetamol are characterized for identification purpose. This work covers a wide THz spectral range namely, 2-18 THz. This proposed simple but novel technique, the tape method, was used for characterizing API and identifying their presence in their dosage forms. By comparing the spectra of the APIs to their dosage forms (powder samples), all distinct fingerprints present in the APIs are also present in their respective dosage forms. The positions of the spectral features obtained with the ATR techniques were akin to that obtained from the tape method. The ATR and the tape method therefore, complement each other. The presence of distinct fingerprints in this spectral range has highlighted the possibility of developing fast THz sensors for the screening of pharmaceuticals. It is worth noting that, the ATR method is applicable to flat faced tablets whereas the tape method is suitable for powders in general (e.g. curved surface tablets that require milling before measurement). Finally, we have demonstrated that ATR techniques can be used to screen counterfeit antimalarial tablets.

  9. Pitfalls in the measurement of muscle mass: a need for a reference standard

    PubMed Central

    Landi, Francesco; Cesari, Matteo; Fielding, Roger A.; Visser, Marjolein; Engelke, Klaus; Maggi, Stefania; Dennison, Elaine; Al‐Daghri, Nasser M.; Allepaerts, Sophie; Bauer, Jurgen; Bautmans, Ivan; Brandi, Maria Luisa; Bruyère, Olivier; Cederholm, Tommy; Cerreta, Francesca; Cherubini, Antonio; Cooper, Cyrus; Cruz‐Jentoft, Alphonso; McCloskey, Eugene; Dawson‐Hughes, Bess; Kaufman, Jean‐Marc; Laslop, Andrea; Petermans, Jean; Reginster, Jean‐Yves; Rizzoli, René; Robinson, Sian; Rolland, Yves; Rueda, Ricardo; Vellas, Bruno; Kanis, John A.

    2018-01-01

    Abstract Background All proposed definitions of sarcopenia include the measurement of muscle mass, but the techniques and threshold values used vary. Indeed, the literature does not establish consensus on the best technique for measuring lean body mass. Thus, the objective measurement of sarcopenia is hampered by limitations intrinsic to assessment tools. The aim of this study was to review the methods to assess muscle mass and to reach consensus on the development of a reference standard. Methods Literature reviews were performed by members of the European Society for Clinical and Economic Aspects of Osteoporosis and Osteoarthritis working group on frailty and sarcopenia. Face‐to‐face meetings were organized for the whole group to make amendments and discuss further recommendations. Results A wide range of techniques can be used to assess muscle mass. Cost, availability, and ease of use can determine whether the techniques are better suited to clinical practice or are more useful for research. No one technique subserves all requirements but dual energy X‐ray absorptiometry could be considered as a reference standard (but not a gold standard) for measuring muscle lean body mass. Conclusions Based on the feasibility, accuracy, safety, and low cost, dual energy X‐ray absorptiometry can be considered as the reference standard for measuring muscle mass. PMID:29349935

  10. Comparison of methods to assess energy expenditure and physical activity in people with spinal cord injury

    PubMed Central

    Tanhoffer, Ricardo A.; Tanhoffer, Aldre I. P.; Raymond, Jacqueline; Hills, Andrew P.; Davis, Glen M.

    2012-01-01

    Objective To compare different methods of assessing energy expenditure (EE) and physical activity (PA) in people with spinal cord injury (SCI) under community-dwelling conditions. Methods A reference standard encompassing the doubly labelled water (DLW) technique, heart rate monitoring (FLEX-HR), a multi-sensor armband (SenseWear Armband (SWA)), and two PA recall questionnaires were employed in 14 people with SCI to estimate EE and leisure-time PA. Results Mean total daily energy expenditure (TDEE) assessed by DLW, FLEX-HR, and SWA were 9817 ± 2491 kJ/day, 8498 ± 1516 kJ/day, and 11414 ± 3242 kJ/day, respectively. Physical activity energy expenditure (PAEE) quantified by DLW was 2841 ± 1626 kJ/day, 2935 ± 1732 kJ/day estimated from FLEX-HR, and 2773 ± 2966 kJ/day derived from SWA. After converting the PA recall questionnaire data to EE in kJ/day, PAEE for the Physical Activity Recall Assessment for People with Spinal Cord Injury (PARA-SCI) was 2339 ± 1171 kJ/day and for Physical Activity Scale for Individuals with Physical Disabilities (PASIPD) 749 ± 1026 kJ/day. DLW-quantified PAEE was moderately associated with PARA-SCI (R2 = 0.62, P < 0.05), but not with the other estimates of PAEE (R2 ranged between 0.13 and 0.30, P > 0.05). Conclusion Our findings revealed that the PARA-SCI recall questionnaire was the best estimate of PAEE compared to the reference standard DLW approach. Although the between-method variability for SWA, FLEX-HR, and PASIPD-derived PAEE was small, there was a weak association between these methods and the criterion DLW technique. The best estimate of DLW-quantified TDEE was by FLEX-HR. SWA significantly overestimated TDEE in this population. PMID:22330189

  11. Advanced Gas Turbine (AGT) Technology Development Project, ceramic component developments

    NASA Technical Reports Server (NTRS)

    Teneyck, M. O.; Macbeth, J. W.; Sweeting, T. B.

    1987-01-01

    The ceramic component technology development activity conducted by Standard Oil Engineered Materials Company while performing as a principal subcontractor to the Garrett Auxiliary Power Division for the Advanced Gas Turbine (AGT) Technology Development Project (NASA Contract DEN3-167) is summarized. The report covers the period October 1979 through July 1987, and includes information concerning ceramic technology work categorized as common and unique. The former pertains to ceramic development applicable to two parallel AGT projects established by NASA contracts DEN3-168 (AGT100) and DEN3-167 (AGT101), whereas the unique work solely pertains to Garrett directed activity under the latter contract. The AGT101 Technology Development Project is sponsored by DOE and administered by NASA-Lewis. Standard Oil directed its efforts toward the development of ceramic materials in the silicon-carbide family. Various shape forming and fabrication methods, and nondestructive evaluation techniques were explored to produce the static structural components for the ceramic engine. This permitted engine testing to proceed without program slippage.

  12. Hot topics in noise

    NASA Astrophysics Data System (ADS)

    Stinson, Michael R.

    2003-10-01

    Our world continues to be a noisy place and the challenge to ``increase and diffuse knowledge of noise propagation, passive and active noise control, and the effects of noise'' remains. In the last several years, noise in the classroom has emerged as one of the hotter topics: Considerable progress has been made in the underpinning research, the formulation of recommendations, and the process of educating society on the social and personal impact of inadequate acoustical conditions in classrooms. The establishment of the ANSI S12.60-2002 standard for classroom acoustics was a milestone event. Noise in cities and the understanding of our soundscapes are subjects of ongoing significance. The development of standards and regulations is a continuing process, with urban community noise regulations, aviation noise, and the preservation of natural quiet in national parks being of current concern. New methods to reduce noise are under development and include passive and active methods of noise control, techniques for modeling the performance of noise barriers, and approaches for designing product sound quality.

  13. Accelerated Partial Breast Irradiation: What is Dosimetric Effect of Advanced Technology Approaches?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moran, Jean M.; Ben-David, Merav A.; Marsh, Robin B.

    2009-09-01

    Purpose: The present treatment planning study compared whole breast radiotherapy (WBRT) to accelerated partial breast irradiation (APBI) for different external beam techniques and geometries (e.g., free breathing [FB] and deep inspiration breath hold [DIBH]). Methods and Materials: After approval by our institutional review board, a treatment planning study was performed of 10 patients with left-sided Stage 0-I breast cancer enrolled in a Phase I-II study of APBI using intensity-modulated radiotherapy (IMRT). After lumpectomy, patients underwent planning computed tomography scans during FB and using an active breathing control device at DIBH. For the FB geometry, standard WBRT and three-dimensional conformal radiotherapymore » (3D-CRT) APBI plans were created. For the DIBH geometry with active breathing control, WBRT, 3D-CRT, and IMRT APBI plans were created. Results: All APBI techniques had excellent planning target volume coverage. The maximal planning target volume dose was reduced from 116% of the prescription dose to 108% with the IMRT(DIBH) APBI plan. The maximal heart dose was >30 Gy for the WBRT techniques, 8.2 Gy for 3D-CRT(FB), and <5.0 Gy for 3D-CRT(DIBH) and IMRT(DIBH) techniques. The mean left anterior descending artery dose was significantly reduced from 11.4 Gy with WBRT(FB) to 4.2 with WBRT(DIBH) and <2.0 Gy with all APBI techniques. Conclusion: Although planning target volume coverage was acceptable with all techniques, the plans using the DIBH geometry resulted in a marked reduction in the normal tissue dose compared with WBRT planned in the absence of cardiac blocking. Additional study is needed to determine whether these techniques result in clinical benefits.« less

  14. Fetoscopic Open Neural Tube Defect Repair: Development and Refinement of a Two-Port, Carbon Dioxide Insufflation Technique.

    PubMed

    Belfort, Michael A; Whitehead, William E; Shamshirsaz, Alireza A; Bateni, Zhoobin H; Olutoye, Oluyinka O; Olutoye, Olutoyin A; Mann, David G; Espinoza, Jimmy; Williams, Erin; Lee, Timothy C; Keswani, Sundeep G; Ayres, Nancy; Cassady, Christopher I; Mehollin-Ray, Amy R; Sanz Cortes, Magdalena; Carreras, Elena; Peiro, Jose L; Ruano, Rodrigo; Cass, Darrell L

    2017-04-01

    To describe development of a two-port fetoscopic technique for spina bifida repair in the exteriorized, carbon dioxide-filled uterus and report early results of two cohorts of patients: the first 15 treated with an iterative technique and the latter 13 with a standardized technique. This was a retrospective cohort study (2014-2016). All patients met Management of Myelomeningocele Study selection criteria. The intraoperative approach was iterative in the first 15 patients and was then standardized. Obstetric, maternal, fetal, and early neonatal outcomes were compared. Standard parametric and nonparametric tests were used as appropriate. Data for 28 patients (22 endoscopic only, four hybrid, two abandoned) are reported, but only those with a complete fetoscopic repair were analyzed (iterative technique [n=10] compared with standardized technique [n=12]). Maternal demographics and gestational age (median [range]) at fetal surgery (25.4 [22.9-25.9] compared with 24.8 [24-25.6] weeks) were similar, but delivery occurred at 35.9 (26-39) weeks of gestation with the iterative technique compared with 39 (35.9-40) weeks of gestation with the standardized technique (P<.01). Duration of surgery (267 [107-434] compared with 246 [206-333] minutes), complication rates, preterm prelabor rupture of membranes rates (4/12 [33%] compared with 1/10 [10%]), and vaginal delivery rates (5/12 [42%] compared with 6/10 [60%]) were not statistically different in the iterative and standardized techniques, respectively. In 6 of 12 (50%) compared with 1 of 10 (10%), respectively (P=.07), there was leakage of cerebrospinal fluid from the repair site at birth. Management of Myelomeningocele Study criteria for hydrocephalus-death at discharge were met in 9 of 12 (75%) and 3 of 10 (30%), respectively, and 7 of 12 (58%) compared with 2 of 10 (20%) have been treated for hydrocephalus to date. These latter differences were not statistically significant. Fetoscopic open neural tube defect repair does not appear to increase maternal-fetal complications as compared with repair by hysterotomy, allows for vaginal delivery, and may reduce long-term maternal risks. ClinicalTrials.gov, https://clinicaltrials.gov, NCT02230072.

  15. Gas-cell atomic clocks for space: new results and alternative schemes

    NASA Astrophysics Data System (ADS)

    Affolderbach, C.; Breschi, E.; Schori, C.; Mileti, G.

    2017-11-01

    We present our development activities on compact Rubidium gas-cell atomic frequency standards, for use in space-borne and ground-based applications. We experimentally demonstrate a high-performance laser optically-pumped Rb clock for space applications such as telecommunications, science missions, and satellite navigation systems (e.g. GALILEO). Using a stabilised laser source and optimized gas cells, we reach clock stabilities as low as 1.5·10-12 τ-1/2 up to 103 s and 4·10-14 at 104 s. The results demonstrate the feasibility of a laser-pumped Rb clock reaching < 1·10-12 τ-1/2 in a compact device (<2 liters, 2 kg, 20 W), given optimization of the implemented techniques. A second activity concerns more radically miniaturized gas-cell clocks, aiming for low power consumption and a total volume around 1 cm3 , at the expense of relaxed frequency stability. Here miniaturized "chip-scale" vapour cells and use of coherent laser interrogation techniques are at the heart of the investigations.

  16. A 4-Dimensional Representation of Antennal Lobe Output Based on an Ensemble of Characterized Projection Neurons

    PubMed Central

    Staudacher, Erich M.; Huetteroth, Wolf; Schachtner, Joachim; Daly, Kevin C.

    2009-01-01

    A central problem facing studies of neural encoding in sensory systems is how to accurately quantify the extent of spatial and temporal responses. In this study, we take advantage of the relatively simple and stereotypic neural architecture found in invertebrates. We combine standard electrophysiological techniques, recently developed population analysis techniques, and novel anatomical methods to form an innovative 4-dimensional view of odor output representations in the antennal lobe of the moth Manduca sexta. This novel approach allows quantification of olfactory responses of characterized neurons with spike time resolution. Additionally, arbitrary integration windows can be used for comparisons with other methods such as imaging. By assigning statistical significance to changes in neuronal firing, this method can visualize activity across the entire antennal lobe. The resulting 4-dimensional representation of antennal lobe output complements imaging and multi-unit experiments yet provides a more comprehensive and accurate view of glomerular activation patterns in spike time resolution. PMID:19464513

  17. Large-area PSPMT based gamma-ray imager with edge reclamation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ziock, K-P; Nakae, L

    2000-09-21

    We describe a coded aperture, gamma-ray imager which uses a CsI(Na) scintillator coupled to an Hamamatsu R3292 position-sensitive photomultiplier tube (PSPMT) as the position-sensitive detector. We have modified the normal resistor divider readout of the PSPMT to allow use of nearly the full 10 cm diameter active area of the PSPMT with a single scintillator crystal one centimeter thick. This is a significant performance improvement over that obtained with the standard readout technique where the linearity and position resolution start to degrade at radii as small as 3.5 cm with a crystal 0.75 crn thick. This represents a recovery ofmore » over 60% of the PSPMT active area. The performance increase allows the construction of an imager with a field of view 20 resolution elements in diameter with useful quantum efficiency from 60-700 keV. In this paper we describe the readout technique, its implementation in a coded aperture imager and the performance of that imager.« less

  18. Preparation and application of in-fibre internal standardization solid-phase microextraction.

    PubMed

    Zhao, Wennan; Ouyang, Gangfeng; Pawliszyn, Janusz

    2007-03-01

    The in-fibre standardization method is a novel approach that has been developed for field sampling/sample preparation, in which an internal standard is pre-loaded onto a solid-phase microextraction (SPME) fibre for calibration of the extraction of target analytes in field samples. The same method can also be used for in-vial sample analysis. In this study, different techniques to load the standard to a non-porous SPME fibre were investigated. It was found that the appropriateness of the technique depends on the physical properties of the standards that are used for the analysis. Headspace extraction of the standard dissolved in pumping oil works well for volatile compounds. Conversely, headspace extraction of the pure standard is an effective approach for semi-volatile compounds. For compounds with low volatility, a syringe-fibre transfer method and direct extraction of the standard dissolved in a solvent exhibited a good reproducibility (<5% RSD). The main advantage of the approaches investigated in this study is that the standard generation vials can be reused for hundreds of analyses without exhibiting significant loss. Moreover, most of the standard loading processes studied can be performed automatically, which is efficient and precise. Finally, the standard loading technique and in-fibre standardization method were applied to a complex matrix (milk) and the results illustrated that the matrix effect can be effectively compensated for with this approach.

  19. Project officer's perspective: quality assurance as a management tool.

    PubMed

    Heiby, J

    1993-06-01

    Advances in the management of health programs in less developed countries (LDC) have not kept pace with the progress of the technology used. The US Agency for International Development mandated the Quality Assurance Project (QAP) to provide quality improvement technical assistance to primary health care systems in LDCs while developing appropriate quality assurance (QA) strategies. The quality of health care in recent years in the US and Europe focused on the introduction of management techniques developed for industry into health systems. The experience of the QAP and its predecessor, the PRICOR Project, shows that quality improvement techniques facilitate measurement of quality of care. A recently developed WHO model for the management of the sick child provides scientifically based standards for actual care. Since 1988, outside investigators measuring how LDC clinicians perform have revealed serious deficiencies in quality compared with the program's own standards. This prompted developed of new QA management initiatives: 1) communicating standards clearly to the program staff; 2) actively monitoring actual performance corresponds to these standards; and 3) taking action to improve performance. QA means that managers are expected to monitor service delivery, undertake problem solving, and set specific targets for quality improvement. Quality improvement methods strengthen supervision as supervisors can objectively assess health worker performance. QA strengthens the management functions that support service delivery, e.g., training, records management, finance, logistics, and supervision. Attention to quality can contribute to improved health worker motivation and effective incentive programs by recognition for a job well done and opportunities for learning new skills. These standards can also address patient satisfaction. QA challenges managers to aim for the optimal level of care attainable.

  20. New Techniques to Evaluate the Incendiary Behavior of Insulators

    NASA Technical Reports Server (NTRS)

    Buhler, Charles; Calle, Carlos; Clements, Sid; Trigwell, Steve; Ritz, Mindy

    2008-01-01

    New techniques for evaluating the incendiary behavior of insulators is presented. The onset of incendive brush discharges in air is evaluated using standard spark probe techniques for the case simulating approaches of an electrically grounded sphere to a charged insulator in the presence of a flammable atmosphere. However, this standard technique is unsuitable for the case of brush discharges that may occur during the charging-separation process for two insulator materials. We present experimental techniques to evaluate this hazard in the presence of a flammable atmosphere which is ideally suited to measure the incendiary nature of micro-discharges upon separation, a measurement never before performed. Other measurement techniques unique to this study include; surface potential measurements of insulators before, during and after contact and separation, as well as methods to verify fieldmeter calibrations using a charge insulator surface opposed to standard high voltage plates. Key words: Kapton polyimide film, incendiary discharges, brush discharges, contact and frictional electrification, ignition hazards, insulators, contact angle, surface potential measurements.

  1. Synthesis and in silico studies of novel sulfonamides having oxadiazole ring: As β-glucuronidase inhibitors.

    PubMed

    Taha, Muhammad; Baharudin, Mohd Syukri; Ismail, Nor Hadiani; Selvaraj, Manikandan; Salar, Uzma; Alkadi, Khaled A A; Khan, Khalid Mohammed

    2017-04-01

    Novel sulfonamides having oxadiazole ring were synthesized by multistep reaction and evaluated to check in vitro β-glucuronidase inhibitory activity. Luckily, except compound 13, all compounds were found to demonstrate good inhibitory activity in the range of IC 50 =2.40±0.01-58.06±1.60μM when compared to the standard d-saccharic acid 1,4-lactone (IC 50 =48.4±1.25μM). Structure activity relationship was also presented. However, in order to ensure the SAR as well as the molecular interactions of compounds with the active site of enzyme, molecular docking studies on most active compounds 19, 16, 4 and 6 was carried out. All derivatives were fully characterized by 1 H NMR, 13 C NMR and EI-MS spectroscopic techniques. CHN analysis was also presented. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Physical Activity during Pregnancy: Recommendations and Assessment Tools.

    PubMed

    Oliveira, Cibele; Imakawa, Thiago Dos Santos; Moisés, Elaine Christine Dantas

    2017-08-01

    The literature that supports and recommends the practice of exercise during pregnancy is extensive.However, although a more complete research on ways to evaluate the physical activity performed by pregnant women has been perfomed, it is found that there is no gold standard and that the articles in the area are inconclusive. Thus, the objective of the present article is to review relevant aspects, such as, technique and applicability of the different methods for the assessment of physical activity during pregnancy to provide more reliable and safe information for health professionals to encourage their pregnant patients to engage in the practice of physical activity. This review concluded that all tools for the analysis of physical activity have limitations. Thus, it is necessary to establish the objectives of evaluation in an appropriate manner, as well as to determine their viability and cost-effectiveness for the population under study. Thieme Revinter Publicações Ltda Rio de Janeiro, Brazil.

  3. Extragalactic counterparts to Einstein slew survey sources

    NASA Technical Reports Server (NTRS)

    Schachter, Jonathan F.; Elvis, Martin; Plummer, David; Remillard, Ron

    1992-01-01

    The Einstein slew survey consists of 819 bright X-ray sources, of which 636 (or 78 percent) are identified with counterparts in standard catalogs. The importance of bright X-ray surveys is stressed, and the slew survey is compared to the Rosat all sky survey. Statistical techniques for minimizing confusion in arcminute error circles in digitized data are discussed. The 238 slew survey active galactic nuclei, clusters, and BL Lacertae objects identified to date and their implications for logN-logS and source evolution studies are described.

  4. The National Shipbuilding Research Program. 1989 Ship Production Symposium. Paper No. 13: NIDDESC: Meeting the Data Exchange Challenge Through a Cooperative Effort

    DTIC Science & Technology

    1989-09-01

    RESPONSIBLE PERSON a. REPORT unclassified b. ABSTRACT unclassified c . THIS PAGE unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18... Computer Aided Design (CAD) and Manufacturing (CAM) techniques in the marine industry has increased significantly in recent years, With more...somewhat from ship to ship. All of the activities and companies involved have improved this process by utilizing computer tools. For example, many

  5. Activities and Updates at the State Time and Frequency Standard of Russia

    DTIC Science & Technology

    2009-11-01

    differentially calibrated relative to a portable receiver as part of a calibration campaign arranged by the BIPM. A TWSTFT station is under construction in...with GNSS techniques, a TWSTFT station is under construction right now in Mendeleevo. The closest main goal is to arrange a time link to PTB and NICT...via the IS-4 satellite at a 1-ns accuracy level and improve considerably our time link to UTC. The next possible place for a TWSTFT station is

  6. Comparison of the transformation temperatures of heat-activated Nickel-Titanium orthodontic archwires by two different techniques.

    PubMed

    Obaisi, Noor Aminah; Galang-Boquiren, Maria Therese S; Evans, Carla A; Tsay, Tzong Guang Peter; Viana, Grace; Berzins, David; Megremis, Spiro

    2016-07-01

    The purpose of this study was to investigate the suitability of the Bend and Free Recovery (BFR) method as a standard test method to determine the transformation temperatures of heat-activated Ni-Ti orthodontic archwires. This was done by determining the transformation temperatures of two brands of heat-activated Ni-Ti orthodontic archwires using the both the BFR method and the standard method of Differential Scanning Calorimetry (DSC). The values obtained from the two methods were compared with each other and to the manufacturer-listed values. Forty heat-activated Ni-Ti archwires from both Rocky Mountain Orthodontics (RMO) and Opal Orthodontics (Opal) were tested using BFR and DSC. Round (0.016 inches) and rectangular (0.019×0.025 inches) archwires from each manufacturer were tested. The austenite start temperatures (As) and austenite finish temperatures (Af) were recorded. For four of the eight test groups, the BFR method resulted in lower standard deviations than the DSC method, and, overall, the average standard deviation for BFR testing was slightly lower than for DSC testing. Statistically significant differences were seen between the transformation temperatures obtained from the BFR and DSC test methods. However, the Af temperatures obtained from the two methods were remarkably similar with the mean differences ranging from 0.0 to 2.1°C: Af Opal round (BFR 26.7°C, DSC 27.6°C) and rectangular (BFR 27.6°C, DSC 28.6°C); Af RMO round (BFR 25.5°C, DSC 25.5°C) and rectangular (BFR 28.0°C, DSC 25.9°C). Significant differences were observed between the manufacturer-listed transformation temperatures and those obtained with BFR and DSC testing for both manufacturers. The results of this study suggest that the Bend and Free Recovery method is suitable as a standard method to evaluate the transformation temperatures of heat-activated Ni-Ti orthodontic archwires. Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  7. On the Performance Evaluation of 3D Reconstruction Techniques from a Sequence of Images

    NASA Astrophysics Data System (ADS)

    Eid, Ahmed; Farag, Aly

    2005-12-01

    The performance evaluation of 3D reconstruction techniques is not a simple problem to solve. This is not only due to the increased dimensionality of the problem but also due to the lack of standardized and widely accepted testing methodologies. This paper presents a unified framework for the performance evaluation of different 3D reconstruction techniques. This framework includes a general problem formalization, different measuring criteria, and a classification method as a first step in standardizing the evaluation process. Performance characterization of two standard 3D reconstruction techniques, stereo and space carving, is also presented. The evaluation is performed on the same data set using an image reprojection testing methodology to reduce the dimensionality of the evaluation domain. Also, different measuring strategies are presented and applied to the stereo and space carving techniques. These measuring strategies have shown consistent results in quantifying the performance of these techniques. Additional experiments are performed on the space carving technique to study the effect of the number of input images and the camera pose on its performance.

  8. Microbioassay of Antimicrobial Agents

    PubMed Central

    Simon, Harold J.; Yin, E. Jong

    1970-01-01

    A previously described agar-diffusion technique for microbioassay of antimicrobial agents has been modified to increase sensitivity of the technique and to extend the range of antimicrobial agents to which it is applicable. This microtechnique requires only 0.02 ml of an unknown test sample for assay, and is capable of measuring minute concentrations of antibiotics in buffer, serum, and urine. In some cases, up to a 20-fold increase in sensitivity is gained relative to other published standardized methods and the error of this method is less than ±5%. Buffer standard curves have been established for this technique, concurrently with serum standard curves, yielding information on antimicrobial serum-binding and demonstrating linearity of the data points compared to the estimated regression line for the microconcentration ranges covered by this technique. This microassay technique is particularly well suited for pediatric research and for other investigations where sample volumes are small and quantitative accuracy is desired. Dilution of clinical samples to attain concentrations falling with the range of this assay makes the technique readily adaptable and suitable for general clinical pharmacological studies. The microassay technique has been standardized in buffer solutions and in normal human serum pools for the following antimicrobials: ampicillin, methicillin, penicillin G, oxacillin, cloxacillin, dicloxacillin, cephaloglycin, cephalexin, cephaloridine, cephalothin, erythromycin, rifamycin amino methyl piperazine, kanamycin, neomycin, streptomycin, colistin, polymyxin B, doxycycline, minocycline, oxytetracycline, tetracycline, and chloramphenicol. PMID:4986725

  9. Standardization of the Descemet membrane endothelial keratoplasty technique: Outcomes of the first 450 consecutive cases.

    PubMed

    Satué, M; Rodríguez-Calvo-de-Mora, M; Naveiras, M; Cabrerizo, J; Dapena, I; Melles, G R J

    2015-08-01

    To evaluate the clinical outcome of the first 450 consecutive cases after Descemet membrane endothelial keratoplasty (DMEK), as well as the effect of standardization of the technique. Comparison between 3 groups: Group I: (cases 1-125), as the extended learning curve; Group II: (cases 126-250), transition to technique standardization; Group III: (cases 251-450), surgery with standardized technique. Best corrected visual acuity, endothelial cell density, pachymetry and intra- and postoperative complications were evaluated before, and 1, 3 and 6 months after DMEK. At 6 months after surgery, 79% of eyes reached a best corrected visual acuity of≥0.8 and 43%≥1.0. Mean preoperative endothelial cell density was 2,530±220 cells/mm2 and 1,613±495 at 6 months after surgery. Mean pachymetry measured 668±92 μm and 526±46 μm pre- and (6 months) postoperatively, respectively. There were no significant differences in best corrected visual acuity, endothelial cell density and pachymetry between the 3 groups (P > .05). Graft detachment presented in 17.3% of the eyes. The detachment rate declined from 24% to 12%, and the rate of secondary surgeries from 9.6% to 3.5%, from group I to III respectively. Visual outcomes and endothelial cell density after DMEK are independent of the technique standardization. However, technique standardization may have contributed to a lower graft detachment rate and a relatively low number of secondary interventions required. As such, DMEK may become the first choice of treatment in corneal endothelial disease. Copyright © 2014 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  10. Prevention of neonatal late-onset sepsis: a randomised controlled trial.

    PubMed

    Alcock, Gary; Liley, Helen G; Cooke, Lucy; Gray, Peter H

    2017-04-04

    Late-onset sepsis (LOS), defined as sepsis occurring after 48 h of age causes substantial mortality and morbidity in very low birth weight infants. Risk factors for LOS include immaturity, intravascular catheters, mechanical ventilation, and prolonged parenteral nutrition (PN). Little attention has been paid to studying the effects of PN administration methods. The aim of the study was to compare a bundle of measures for PN line management incorporating a strict aseptic technique with standard line management on LOS in very low birth weight infants. Infants <1500 g birth weight who required PN were randomised to either a bundle of a strict aseptic technique for line management together with single use intravascular catheter for PN or a standard technique. The primary outcome was the incidence of LOS in the first 28 days of life. Secondary outcomes were mortality, neonatal morbidities and developmental outcome at 12 months of age. There were 126 infants in the aseptic technique group and 123 in the standard technique group. Forty (31.8%) infants in the aseptic technique group and 36 (29.3%) in the standard technique group had an episode of sepsis (p = 0.77). This corresponds to incidences of 15.8 and 14.2 episodes of sepsis per 1000 patient days respectively. Subgroup analyses for infants <1000 g also revealed no difference in the rate of sepsis between the intervention and control groups. (p = 0.43). There were no significant differences in secondary outcomes and development between the groups. A bundle of measures including strict aseptic technique for parenteral nutrition line management did not result in a reduction in LOS when compared to a standard technique. There is no evidence to recommend this as routine practice. Interdisciplinary Maternal Perinatal Australasian Collaborative Trials (IMPACT) Network, TRN registration number: PT0363. Date: 06/03/2001; Australian New Zealand Clinical Trials Registry (ANZCTR), TRN registration number: ACTRN12617000455369 . Date: 28/03/2017 (retrospectively registered).

  11. C-MOS bulk metal design handbook. [LSI standard cell (circuits)

    NASA Technical Reports Server (NTRS)

    Edge, T. M.

    1977-01-01

    The LSI standard cell array technique was used in the fabrication of more than 20 CMOS custom arrays. This technique consists of a series of computer programs and design automation techniques referred to as the Computer Aided Design And Test (CADAT) system that automatically translate a partitioned logic diagram into a set of instructions for driving an automatic plotter which generates precision mask artwork for complex LSI arrays of CMOS standard cells. The standard cell concept for producing LSI arrays begins with the design, layout, and validation of a group of custom circuits called standard cells. Once validated, these cells are given identification or pattern numbers and are permanently stored. To use one of these cells in a logic design, the user calls for the desired cell by pattern number. The Place, Route in Two Dimension (PR2D) computer program is then used to automatically generate the metalization and/or tunnels to interconnect the standard cells into the required function. Data sheets that describe the function, artwork, and performance of each of the standard cells, the general procedure for implementation of logic in CMOS standard cells, and additional detailed design information are presented.

  12. Multi-quadrant biopsy technique improves diagnostic ability in large heterogeneous renal masses. Abel EJ, Heckman JE, Hinshaw L, Best S, Lubner M, Jarrard DF, Downs TM, Nakada SY, Lee FT Jr, Huang W, Ziemlewicz T.J Urol. 2015 Oct;194(4):886-91. [Epub 2015 Mar 30]. doi: 10.1016/j.juro.2015.03.106.

    PubMed

    Jay, Raman; Heckman, J E; Hinshaw, L; Best, S; Lubner, M; Jarrard, D F; Downs, T M; Nakada, S Y; Lee, F T; Huang, W; Ziemlewicz, T

    2017-03-01

    Percutaneous biopsy obtained from a single location is prone to sampling error in large heterogeneous renal masses, leading to nondiagnostic results or failure to detect poor prognostic features. We evaluated the accuracy of percutaneous biopsy for large renal masses using a modified multi-quadrant technique vs. a standard biopsy technique. Clinical and pathological data for all patients with cT2 or greater renal masses who underwent percutaneous biopsy from 2009 to 2014 were reviewed. The multi-quadrant technique was defined as multiple core biopsies from at least 4 separate solid enhancing areas in the tumor. The incidence of nondiagnostic findings, sarcomatoid features and procedural complications was recorded, and concordance between biopsy specimens and nephrectomy pathology was compared. A total of 122 biopsies were performed for 117 tumors in 116 patients (46 using the standard biopsy technique and 76 using the multi-quadrant technique). Median tumor size was 10cm (IQR: 8-12). Biopsy was nondiagnostic in 5 of 46 (10.9%) standard and 0 of 76 (0%) multi-quadrant biopsies (P = 0.007). Renal cell carcinoma was identified in 96 of 115 (82.0%) tumors and nonrenal cell carcinoma tumors were identified in 21 (18.0%). One complication occurred using the standard biopsy technique and no complications were reported using the multi-quadrant technique. Sarcomatoid features were present in 23 of 96 (23.9%) large renal cell carcinomas studied. Sensitivity for identifying sarcomatoid features was higher using the multi-quadrant technique compared to the standard biopsy technique at 13 of 15 (86.7%) vs. 2 of 8 (25.0%) (P = 0.0062). The multi-quadrant percutaneous biopsy technique increases the ability to identify aggressive pathological features in large renal tumors and decreases nondiagnostic biopsy rates. Copyright © 2017. Published by Elsevier Inc.

  13. International Standardization of Library and Documentation Techniques.

    ERIC Educational Resources Information Center

    International Federation for Documentation, The Hague (Netherlands).

    This comparative study of the national and international standards, rules and regulations on library and documentation techniques adopted in various countries was conducted as a preliminary step in determining the minimal bases for facilitating national and international cooperation between documentalists and librarians. The study compares and…

  14. Cross-platform comparison of nucleic acid hybridization: toward quantitative reference standards.

    PubMed

    Halvorsen, Ken; Agris, Paul F

    2014-11-15

    Measuring interactions between biological molecules is vitally important to both basic and applied research as well as development of pharmaceuticals. Although a wide and growing range of techniques is available to measure various kinetic and thermodynamic properties of interacting biomolecules, it can be difficult to compare data across techniques of different laboratories and personnel or even across different instruments using the same technique. Here we evaluate relevant biological interactions based on complementary DNA and RNA oligonucleotides that could be used as reference standards for many experimental systems. We measured thermodynamics of duplex formation using isothermal titration calorimetry, differential scanning calorimetry, and ultraviolet-visible (UV-vis) monitored denaturation/renaturation. These standards can be used to validate results, compare data from disparate techniques, act as a teaching tool for laboratory classes, or potentially to calibrate instruments. The RNA and DNA standards have many attractive features, including low cost, high purity, easily measurable concentrations, and minimal handling concerns, making them ideal for use as a reference material. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. CONFERENCE NOTE: CETO—Centro de Ciências e Tecnologias Opticas, Trends in Optical Fibre Metrology and Standards

    NASA Astrophysics Data System (ADS)

    1994-01-01

    Summer School, 27 June to 8 July 1994, Viana do Castelo, Hotel do Parque, Portugal Optical fibres, with their extremely low transmission loss, untapped bandwidth and controllable dispersion, dominate a broad range of technologies in which applications must respond to the increasing constraints of today's specifications as well as envisage future requirements. Optical fibres dominate communications systems. In the area of sensors, fibre optics will be fully exploited for their immunity to EMI, their high sensitivity and their large dynamic range. The maturity of single mode optical technology has led to intensive R&D of a range of components based on the advantages of transmission characteristics and signal processing. Specifications and intercompatibility requests for the new generation of both analogue and digital fibre optical components and systems has created a demand for sophisticated measuring techniques based on unique and complex instruments. In recent years there has been a signification evolution in response to the explosion of applications and the tightening of specifications. These developments justify a concerted effort to focus on trends in optical fibre metrology and standards. Objective The objective of this school is to provide a progressive and comprehensive presentation of current issues concerning passive and active optical fibre characterization and measurement techniques. Passive fibre components support a variety of developments in optical fibre systems and will be discussed in terms of relevance and standards. Particular attention will be paid to devices for metrological purposes such as reference fibres and calibration artefacts. The characterization and testing of optical fibre amplifiers, which have great potential in telecommunications, data distribution networks and as a system part in instrumentation, will be covered. Methods of measurement and means of calibration with traceability will be discussed, together with the characterization requirements of the new generation of analogue and digital fibre optical systems, which require sophisticated measurement techniques employing complex instruments unique to optical measurements. The school will foster and enhance the interaction between material, devices, systems, and standards-oriented R&D communities, as well as between engineers concerned with design and manufacturers of systems and instrumentation. Topics Review of optical fibre communication technology and systems Measurement techniques for fibre characterization: Reliability and traceability Reference fibres and calibration artefacts Ribbon fibres Mechanical and environmental testing Fibre reliability Polarimetric measurements Passive components characterization: Splices and connectors Couplers, splitters, taps and WDMs Optical fibres and isolators WDM technologies and applications: WDM technologies Tunable optical filters Fibre amplifiers and sources: Performances and characterization Design and standards Nonlinear effects Subsystem design and standards: Design and fabrication techniques Performance degradation and reliability Evaluation of costs/performance/technology Sensors IR - optical fibres Plastic fibres Instrumentation Registration Participation free of charge for postgraduate students, with some grants available for travel and lodging expenses. All correspondence should be addressed to: Secretariat, Trends in Optical Fibre Metrology and Standards, a/c Prof. Olivério D D Soares, Centro de Ciências e Tecnologias Opticas, Lab. Fisica - Faculdade de Ciências, Praça Gomes Teixeira, P-4000 Porto, Portugal. Tel: 351-2-310290, 351-2-2001648; Fax: 351-2-319267.

  16. Pomegranate extract exhibits in vitro activity against Clostridium difficile.

    PubMed

    Finegold, Sydney M; Summanen, Paula H; Corbett, Karen; Downes, Julia; Henning, Susanne M; Li, Zhaoping

    2014-10-01

    To determine the possible utility of pomegranate extract in the management or prevention of Clostridium difficile infections or colonization. The activity of pomegranate was tested against 29 clinical C. difficile isolates using the Clinical and Laboratory Standards Institute-approved agar dilution technique. Total phenolics content of the pomegranate extract was determined by Folin-Ciocalteau colorimetric method and final concentrations of 6.25 to 400 μg/mL gallic acid equivalent were achieved in the agar. All strains had MICs at 12.5 to 25 mg/mL gallic acid equivalent range. Our results suggest antimicrobial in vitro activity for pomegranate extract against toxigenic C. difficile. Pomegranate extract may be a useful contributor to the management and prevention of C. difficile disease or colonization. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. A Novel Technique for Inferior Vena Cava Filter Extraction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnston, Edward William, E-mail: ed.johnston@doctors.org.uk; Rowe, Luke Michael Morgan; Brookes, Jocelyn

    Inferior vena cava (IVC) filters are used to protect against pulmonary embolism in high-risk patients. Whilst the insertion of retrievable IVC filters is gaining popularity, a proportion of such devices cannot be removed using standard techniques. We describe a novel approach for IVC filter removal that involves snaring the filter superiorly along with the use of flexible forceps or laser devices to dissect the filter struts from the caval wall. This technique has used to successfully treat three patients without complications in whom standard techniques failed.

  18. Technique for calibrating angular measurement devices when calibration standards are unavailable

    NASA Technical Reports Server (NTRS)

    Finley, Tom D.

    1991-01-01

    A calibration technique is proposed that will allow the calibration of certain angular measurement devices without requiring the use of absolute standard. The technique assumes that the device to be calibrated has deterministic bias errors. A comparison device must be available that meets the same requirements. The two devices are compared; one device is then rotated with respect to the other, and a second comparison is performed. If the data are reduced using the described technique, the individual errors of the two devices can be determined.

  19. Minimally invasive approach for adrenal lesions: Systematic review of laparoscopic versus retroperitoneoscopic adrenalectomy and assessment of risk factors for complications.

    PubMed

    Conzo, G; Tartaglia, E; Gambardella, C; Esposito, D; Sciascia, V; Mauriello, C; Nunziata, A; Siciliano, G; Izzo, G; Cavallo, F; Thomas, G; Musella, M; Santini, L

    2016-04-01

    In the last decades, minimally invasive transperitoneal laparoscopic adrenalectomy has become the standard of care for surgical resection of the adrenal gland tumors. Recently, however, adrenalectomy by a mininvasive retroperitoneal approach has reached increasingly popularity as alternative technique. Short hospitalization, lower postoperative pain and decrease of complications and a better cosmetic resolution are the main advantages of these innovative techniques. In order to determine the better surgical management of adrenal neoplasms, the Authors analyzed and compared the feasibility and the postoperative complications of minimally invasive adrenalectomy approaches. A systematic research of the English literature, including major meta-analysis articles, clinical randomized trials, retrospective studies and systematic reviews was performed, comparing laparoscopic transperitoneal adrenalectomy versus retroperitoneoscopic adrenalectomy. Many studies support that posterior retroperitoneal adrenalectomy is superior or at least comparable to laparoscopic transperitoneal adrenalectomy in operation time, pain score, blood loss, hospitalization, complications rates and return to normal activity. However, laparoscopic transperitoneal adrenalectomy is up to now a safe and standardized procedure with a shorter learning curve and a similar low morbidity rate, even for tumors larger than 6 cm. Nevertheless, further studies are needed to objectively evaluate these techniques, excluding selection bias and bias related to differences in surgeons' experiences with this approaches. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.

  20. [How to write an andrological paper: standardization, mechanics and techniques].

    PubMed

    Huang, Yu-Feng; Lu, Jin-Chun

    2010-12-01

    Andrological research papers not only reflect the current status and academic level of andrology, but also constitute an important communication platform for researchers and clinicians engaged in this field and contribute significantly to the development of andrology. It would be made easier to write a high-quality andrological paper once the author observes the basic requirements of research papers, adheres to the use of standard scientific terminology, knows the special writing mechanics, and equips himself with some essential writing techniques. Based on the long experience of editorship, we present a detailed introduction of the standardization, mechanics and techniques of writing an andrological paper.

  1. 2-Aryl benzimidazoles: Synthesis, In vitro α-amylase inhibitory activity, and molecular docking study.

    PubMed

    Adegboye, Akande Akinsola; Khan, Khalid Mohammed; Salar, Uzma; Aboaba, Sherifat Adeyinka; Kanwal; Chigurupati, Sridevi; Fatima, Itrat; Taha, Mohammad; Wadood, Abdul; Mohammad, Jahidul Isalm; Khan, Huma; Perveen, Shahnaz

    2018-04-25

    Despite of many diverse biological activities exhibited by benzimidazole scaffold, it is rarely explored for the α-amylase inhibitory activity. For that purpose, 2-aryl benzimidazole derivatives 1-45 were synthesized and screened for in vitro α-amylase inhibitory activity. Structures of all synthetic compounds were deduced by various spectroscopic techniques. All compounds revealed inhibition potential with IC 50 values of 1.48 ± 0.38-2.99 ± 0.14 μM, when compared to the standard acarbose (IC 50  = 1.46 ± 0.26 μM). Limited SAR suggested that the variation in the inhibitory activities of the compounds are the result of different substitutions on aryl ring. In order to rationalize the binding interactions of most active compounds with the active site of α-amylase enzyme, in silico study was conducted. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  2. Multisensor data fusion for physical activity assessment.

    PubMed

    Liu, Shaopeng; Gao, Robert X; John, Dinesh; Staudenmayer, John W; Freedson, Patty S

    2012-03-01

    This paper presents a sensor fusion method for assessing physical activity (PA) of human subjects, based on support vector machines (SVMs). Specifically, acceleration and ventilation measured by a wearable multisensor device on 50 test subjects performing 13 types of activities of varying intensities are analyzed, from which activity type and energy expenditure are derived. The results show that the method correctly recognized the 13 activity types 88.1% of the time, which is 12.3% higher than using a hip accelerometer alone. Also, the method predicted energy expenditure with a root mean square error of 0.42 METs, 22.2% lower than using a hip accelerometer alone. Furthermore, the fusion method was effective in reducing the subject-to-subject variability (standard deviation of recognition accuracies across subjects) in activity recognition, especially when data from the ventilation sensor were added to the fusion model. These results demonstrate that the multisensor fusion technique presented is more effective in identifying activity type and energy expenditure than the traditional accelerometer-alone-based methods.

  3. Activities identification for activity-based cost/management applications of the diagnostics outpatient procedures.

    PubMed

    Alrashdan, Abdalla; Momani, Amer; Ababneh, Tamador

    2012-01-01

    One of the most challenging problems facing healthcare providers is to determine the actual cost for their procedures, which is important for internal accounting and price justification to insurers. The objective of this paper is to find suitable categories to identify the diagnostic outpatient medical procedures and translate them from functional orientation to process orientation. A hierarchal task tree is developed based on a classification schema of procedural activities. Each procedure is seen as a process consisting of a number of activities. This makes a powerful foundation for activity-based cost/management implementation and provides enough information to discover the value-added and non-value-added activities that assist in process improvement and eventually may lead to cost reduction. Work measurement techniques are used to identify the standard time of each activity at the lowest level of the task tree. A real case study at a private hospital is presented to demonstrate the proposed methodology. © 2011 National Association for Healthcare Quality.

  4. Causal Entropies – a measure for determining changes in the temporal organization of neural systems

    PubMed Central

    Waddell, Jack; Dzakpasu, Rhonda; Booth, Victoria; Riley, Brett; Reasor, Jonathan; Poe, Gina; Zochowski, Michal

    2009-01-01

    We propose a novel measure to detect temporal ordering in the activity of individual neurons in a local network, which is thought to be a hallmark of activity-dependent synaptic modifications during learning. The measure, called Causal Entropy, is based on the time-adaptive detection of asymmetries in the relative temporal patterning between neuronal pairs. We characterize properties of the measure on both simulated data and experimental multiunit recordings of hippocampal neurons from the awake, behaving rat, and show that the metric can more readily detect those asymmetries than standard cross correlation-based techniques, especially since the temporal sensitivity of causal entropy can detect such changes rapidly and dynamically. PMID:17275095

  5. Image Accumulation in Pixel Detector Gated by Late External Trigger Signal and its Application in Imaging Activation Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jakubek, J.; Cejnarova, A.; Platkevic, M.

    Single quantum counting pixel detectors of Medipix type are starting to be used in various radiographic applications. Compared to standard devices for digital imaging (such as CCDs or CMOS sensors) they present significant advantages: direct conversion of radiation to electric signal, energy sensitivity, noiseless image integration, unlimited dynamic range, absolute linearity. In this article we describe usage of the pixel device TimePix for image accumulation gated by late trigger signal. Demonstration of the technique is given on imaging coincidence instrumental neutron activation analysis (Imaging CINAA). This method allows one to determine concentration and distribution of certain preselected element in anmore » inspected sample.« less

  6. Semiconductor technology in protein kinase research and drug discovery: sensing a revolution.

    PubMed

    Bhalla, Nikhil; Di Lorenzo, Mirella; Estrela, Pedro; Pula, Giordano

    2017-02-01

    Since the discovery of protein kinase activity in 1954, close to 600 kinases have been discovered that have crucial roles in cell physiology. In several pathological conditions, aberrant protein kinase activity leads to abnormal cell and tissue physiology. Therefore, protein kinase inhibitors are investigated as potential treatments for several diseases, including dementia, diabetes, cancer and autoimmune and cardiovascular disease. Modern semiconductor technology has recently been applied to accelerate the discovery of novel protein kinase inhibitors that could become the standard-of-care drugs of tomorrow. Here, we describe current techniques and novel applications of semiconductor technologies in protein kinase inhibitor drug discovery. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Synthesis, Spectral investigation (¹H, ¹³C) and Anti-microbial Screening of benzophenone imines.

    PubMed

    Khosa, Muhammad Kaleem; Jamal, Muhammad Asghar; Saif, Muhammad Jawad; Muneer, Majid; Rehman, Fazalur; Farman, Muhammad; Shoaib, Hafiz Muhammad; Shahid, Muhammad; Hameed, Shabnam

    2015-11-01

    New series of benzophenone imines with general formula Ph2-C=NR; R = Benzyl, 4-Fluorobenzyl, Naphthyl, Phenyl, 4-Nitrophenyl were synthesized by condensation of dichlorodiphenylmethane and different aromatic primary amines (1:1) Those imines were characterized by different physiochemical and spectroscopic techniques like melting point, elemental analysis, FT-IR, multinuclear NMR (¹H, ¹³C). After characterization, imines were subjected to anti-microbial activities. All compounds showed promising activity against different bacterial strains like Escherichia coli, Bacillussubtilis, Pasturellam ultocida and Staphylococcus aureus as well as fungal strains like Alternata alternaria, Ganoderma lucidium, Penicillium notatum and Trichoderma harzianum using Amoxicillin and Flucanazole as a standard drugs respectively.

  8. Beyond endoscopic assessment in inflammatory bowel disease: real-time histology of disease activity by non-linear multimodal imaging

    NASA Astrophysics Data System (ADS)

    Chernavskaia, Olga; Heuke, Sandro; Vieth, Michael; Friedrich, Oliver; Schürmann, Sebastian; Atreya, Raja; Stallmach, Andreas; Neurath, Markus F.; Waldner, Maximilian; Petersen, Iver; Schmitt, Michael; Bocklitz, Thomas; Popp, Jürgen

    2016-07-01

    Assessing disease activity is a prerequisite for an adequate treatment of inflammatory bowel diseases (IBD) such as Crohn’s disease and ulcerative colitis. In addition to endoscopic mucosal healing, histologic remission poses a promising end-point of IBD therapy. However, evaluating histological remission harbors the risk for complications due to the acquisition of biopsies and results in a delay of diagnosis because of tissue processing procedures. In this regard, non-linear multimodal imaging techniques might serve as an unparalleled technique that allows the real-time evaluation of microscopic IBD activity in the endoscopy unit. In this study, tissue sections were investigated using the non-linear multimodal microscopy combination of coherent anti-Stokes Raman scattering (CARS), two-photon excited auto fluorescence (TPEF) and second-harmonic generation (SHG). After the measurement a gold-standard assessment of histological indexes was carried out based on a conventional H&E stain. Subsequently, various geometry and intensity related features were extracted from the multimodal images. An optimized feature set was utilized to predict histological index levels based on a linear classifier. Based on the automated prediction, the diagnosis time interval is decreased. Therefore, non-linear multimodal imaging may provide a real-time diagnosis of IBD activity suited to assist clinical decision making within the endoscopy unit.

  9. Application of phage display for the development of a novel inhibitor of PLA2 activity in Western cottonmouth venom

    PubMed Central

    Titus, James K; Kay, Matthew K; Glaser, CDR Jacob J

    2017-01-01

    Snakebite envenomation is an important global health concern. The current standard treatment approach for snakebite envenomation relies on antibody-based antisera, which are expensive, not universally available, and can lead to adverse physiological effects. Phage display techniques offer a powerful tool for the selection of phage-expressed peptides, which can bind with high specificity and affinity towards venom components. In this research, the amino acid sequences of Phospholipase A2 (PLA2) from multiple cottonmouth species were analyzed, and a consensus peptide synthesized. Three phage display libraries were panned against this consensus peptide, crosslinked to capillary tubes, followed by a modified surface panning procedure. This high throughput selection method identified four phage clones with anti-PLA2 activity against Western cottonmouth venom, and the amino acid sequences of the displayed peptides were identified. This is the first report identifying short peptide sequences capable of inhibiting PLA2 activity of Western cottonmouth venom in vitro, using a phage display technique. Additionally, this report utilizes synthetic panning targets, designed using venom proteomic data, to mimic epitope regions. M13 phages displaying circular 7-mer or linear 12-mer peptides with antivenom activity may offer a novel alternative to traditional antibody-based therapy. PMID:29285351

  10. Application of phage display for the development of a novel inhibitor of PLA2 activity in Western cottonmouth venom.

    PubMed

    Titus, James K; Kay, Matthew K; Glaser, Cdr Jacob J

    2017-01-01

    Snakebite envenomation is an important global health concern. The current standard treatment approach for snakebite envenomation relies on antibody-based antisera, which are expensive, not universally available, and can lead to adverse physiological effects. Phage display techniques offer a powerful tool for the selection of phage-expressed peptides, which can bind with high specificity and affinity towards venom components. In this research, the amino acid sequences of Phospholipase A 2 (PLA 2 ) from multiple cottonmouth species were analyzed, and a consensus peptide synthesized. Three phage display libraries were panned against this consensus peptide, crosslinked to capillary tubes, followed by a modified surface panning procedure. This high throughput selection method identified four phage clones with anti-PLA 2 activity against Western cottonmouth venom, and the amino acid sequences of the displayed peptides were identified. This is the first report identifying short peptide sequences capable of inhibiting PLA 2 activity of Western cottonmouth venom in vitro , using a phage display technique. Additionally, this report utilizes synthetic panning targets, designed using venom proteomic data, to mimic epitope regions. M13 phages displaying circular 7-mer or linear 12-mer peptides with antivenom activity may offer a novel alternative to traditional antibody-based therapy.

  11. Pitfalls in the measurement of muscle mass: a need for a reference standard.

    PubMed

    Buckinx, Fanny; Landi, Francesco; Cesari, Matteo; Fielding, Roger A; Visser, Marjolein; Engelke, Klaus; Maggi, Stefania; Dennison, Elaine; Al-Daghri, Nasser M; Allepaerts, Sophie; Bauer, Jurgen; Bautmans, Ivan; Brandi, Maria Luisa; Bruyère, Olivier; Cederholm, Tommy; Cerreta, Francesca; Cherubini, Antonio; Cooper, Cyrus; Cruz-Jentoft, Alphonso; McCloskey, Eugene; Dawson-Hughes, Bess; Kaufman, Jean-Marc; Laslop, Andrea; Petermans, Jean; Reginster, Jean-Yves; Rizzoli, René; Robinson, Sian; Rolland, Yves; Rueda, Ricardo; Vellas, Bruno; Kanis, John A

    2018-04-01

    All proposed definitions of sarcopenia include the measurement of muscle mass, but the techniques and threshold values used vary. Indeed, the literature does not establish consensus on the best technique for measuring lean body mass. Thus, the objective measurement of sarcopenia is hampered by limitations intrinsic to assessment tools. The aim of this study was to review the methods to assess muscle mass and to reach consensus on the development of a reference standard. Literature reviews were performed by members of the European Society for Clinical and Economic Aspects of Osteoporosis and Osteoarthritis working group on frailty and sarcopenia. Face-to-face meetings were organized for the whole group to make amendments and discuss further recommendations. A wide range of techniques can be used to assess muscle mass. Cost, availability, and ease of use can determine whether the techniques are better suited to clinical practice or are more useful for research. No one technique subserves all requirements but dual energy X-ray absorptiometry could be considered as a reference standard (but not a gold standard) for measuring muscle lean body mass. Based on the feasibility, accuracy, safety, and low cost, dual energy X-ray absorptiometry can be considered as the reference standard for measuring muscle mass. © 2018 The Authors. Journal of Cachexia, Sarcopenia and Muscle published by John Wiley & Sons Ltd on behalf of the Society on Sarcopenia, Cachexia and Wasting Disorders.

  12. GNSS derived TEC data ingestion into IRI 2012

    NASA Astrophysics Data System (ADS)

    Migoya-Orué, Yenca; Nava, Bruno; Radicella, Sandro; Alazo-Cuartas, Katy

    2015-04-01

    Experimental vertical total electron content (VTEC) data given by Global Ionospheric Maps (GIM) has been ingested into the IRI version 2012, aiming to obtain grids of effective input parameter values that allow to minimize the difference between the experimental and modeled vertical TEC. Making use of the experience gained with the technique of model adaptation applied to NeQuick (Nava et al., 2005), it has been found possible to compute IRI world grids of effective ionosphere index parameters (IG). The IG grids thus obtained can be interpolated in space and time to calculate with IRI the 3D electron density at any location and also the TEC along any ground-to-satellite ray-path for a given epoch. In this study, the ingestion technique is presented and a posteriori validation, along with an assessment of the capability of the 'ingested' IRI to reproduce the ionosphere day-to-day foF2 variability during disturbed and quiet periods. The foF2 values retrieved are compared with data from about 20 worldwide ionosondes for selected periods of high (year 2000) and moderate to low solar activity (year 2006). It was found that the use of the ingestion scheme enhances the performance of the model when compared with its standard use based on solar activity drivers (R12 and F10.7), especially for high solar activity. As an example, the mean and standard deviation of the differences between experimental and reconstructed F2-peak values for April of year 2000 is 0.09 and 1.28 MHz for ingested IRI, compared to -0.81 and 1.27 MHz (IRI with R12 input) and -0.02 and 1.46 MHz (IRI with F10.7 input).

  13. Removal of Phenolic Compounds from Water Using Sewage Sludge-Based Activated Carbon Adsorption: A Review.

    PubMed

    Mu'azu, Nuhu Dalhat; Jarrah, Nabeel; Zubair, Mukarram; Alagha, Omar

    2017-09-21

    Due to their industrial relevance, phenolic compounds (PC) are amongst the most common organic pollutants found in many industrial wastewater effluents. The potential detrimental health and environmental impacts of PC necessitate their removal from wastewater to meet regulatory discharge standards to ensure meeting sustainable development goals. In recent decades, one of the promising, cost-effective and environmentally benign techniques for removal of PC from water streams has been adsorption onto sewage sludge (SS)-based activated carbon (SBAC). This is attributed to the excellent adsorptive characteristics of SBAC and also because the approach serves as a strategy for sustainable management of huge quantities of different types of SS that are in continual production globally. This paper reviews conversion of SS into activated carbons and their utilization for the removal of PC from water streams. Wide ranges of topics which include SBAC production processes, physicochemical characteristics of SBAC, factors affecting PC adsorption onto SBAC and their uptake mechanisms as well as the regeneration potential of spent SBAC are covered. Although chemical activation techniques produce better SBAC, yet more research work is needed to harness advances in material science to improve the functional groups and textural properties of SBAC as well as the low performance of physical activation methods. Studies focusing on PC adsorptive performance on SBAC using continuous mode (that are more relevant for industrial applications) in both single and multi-pollutant aqueous systems to cover wide range of PC are needed. Also, the potentials of different techniques for regeneration of spent SBAC used for adsorption of PC need to be assessed in relation to overall economic evaluation within realm of environmental sustainability using life cycle assessment.

  14. Removal of Phenolic Compounds from Water Using Sewage Sludge-Based Activated Carbon Adsorption: A Review

    PubMed Central

    Jarrah, Nabeel; Zubair, Mukarram; Alagha, Omar

    2017-01-01

    Due to their industrial relevance, phenolic compounds (PC) are amongst the most common organic pollutants found in many industrial wastewater effluents. The potential detrimental health and environmental impacts of PC necessitate their removal from wastewater to meet regulatory discharge standards to ensure meeting sustainable development goals. In recent decades, one of the promising, cost-effective and environmentally benign techniques for removal of PC from water streams has been adsorption onto sewage sludge (SS)-based activated carbon (SBAC). This is attributed to the excellent adsorptive characteristics of SBAC and also because the approach serves as a strategy for sustainable management of huge quantities of different types of SS that are in continual production globally. This paper reviews conversion of SS into activated carbons and their utilization for the removal of PC from water streams. Wide ranges of topics which include SBAC production processes, physicochemical characteristics of SBAC, factors affecting PC adsorption onto SBAC and their uptake mechanisms as well as the regeneration potential of spent SBAC are covered. Although chemical activation techniques produce better SBAC, yet more research work is needed to harness advances in material science to improve the functional groups and textural properties of SBAC as well as the low performance of physical activation methods. Studies focusing on PC adsorptive performance on SBAC using continuous mode (that are more relevant for industrial applications) in both single and multi-pollutant aqueous systems to cover wide range of PC are needed. Also, the potentials of different techniques for regeneration of spent SBAC used for adsorption of PC need to be assessed in relation to overall economic evaluation within realm of environmental sustainability using life cycle assessment. PMID:28934127

  15. Using standardized fishery data to inform rehabilitation efforts

    USGS Publications Warehouse

    Spurgeon, Jonathan J.; Stewart, Nathaniel T.; Pegg, Mark A.; Pope, Kevin L.; Porath, Mark T.

    2016-01-01

    Lakes and reservoirs progress through an aging process often accelerated by human activities, resulting in degradation or loss of ecosystem services. Resource managers thus attempt to slow or reverse the negative effects of aging using a myriad of rehabilitation strategies. Sustained monitoring programs to assess the efficacy of rehabilitation strategies are often limited; however, long-term standardized fishery surveys may be a valuable data source from which to begin evaluation. We present 3 case studies using standardized fishery survey data to assess rehabilitation efforts stemming from the Nebraska Aquatic Habitat Plan, a large-scale program with the mission to rehabilitate waterbodies within the state. The case studies highlight that biotic responses to rehabilitation efforts can be assessed, to an extent, using standardized fishery data; however, there were specific areas where minor increases in effort would clarify the effectiveness of rehabilitation techniques. Management of lakes and reservoirs can be streamlined by maximizing the utility of such datasets to work smarter, not harder. To facilitate such efforts, we stress collecting both biotic (e.g., fish lengths and weight) and abiotic (e.g., dissolved oxygen, pH, and turbidity) data during standardized fishery surveys and designing rehabilitation actions with an appropriate experimental design.

  16. Calibration-free quantitative analysis of elemental ratios in intermetallic nanoalloys and nanocomposites using Laser Induced Breakdown Spectroscopy (LIBS).

    PubMed

    Davari, Seyyed Ali; Hu, Sheng; Mukherjee, Dibyendu

    2017-03-01

    Intermetallic nanoalloys (NAs) and nanocomposites (NCs) have increasingly gained prominence as efficient catalytic materials in electrochemical energy conversion and storage systems. But their morphology and chemical compositions play critical role in tuning their catalytic activities, and precious metal contents. While advanced microscopy techniques facilitate morphological characterizations, traditional chemical characterizations are either qualitative or extremely involved. In this study, we apply Laser Induced Breakdown Spectroscopy (LIBS) for quantitative compositional analysis of NAs and NCs synthesized with varied elemental ratios by our in-house built pulsed laser ablation technique. Specifically, elemental ratios of binary PtNi, PdCo (NAs) and PtCo (NCs) of different compositions are determined from LIBS measurements employing an internal calibration scheme using the bulk matrix species as internal standards. Morphology and qualitative elemental compositions of the aforesaid NAs and NCs are confirmed from Transmission Electron Microscopy (TEM) images and Energy Dispersive X-ray Spectroscopy (EDX) measurements. LIBS experiments are carried out in ambient conditions with the NA and NC samples drop cast on silicon wafers after centrifugation to increase their concentrations. The technique does not call for cumbersome sample preparations including acid digestions and external calibration standards commonly required in Inductively Coupled Plasma-Optical Emission Spectroscopy (ICP-OES) techniques. Yet the quantitative LIBS results are in good agreement with the results from ICP-OES measurements. Our results indicate the feasibility of using LIBS in future for rapid and in-situ quantitative chemical characterizations of wide classes of synthesized NAs and NCs. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Eight piece quadrupole magnet, method for aligning quadrupole magent pole tips

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jaski, Mark S.; Liu, Jie; Donnelly, Aric T.

    The invention provides an alternative to the standard 2-piece or 4-piece quadrupole. For example, an 8-piece and a 10-piece quadrupole are provided whereby the tips of each pole may be adjustable. Also provided is a method for producing a quadrupole using standard machining techniques but which results in a final tolerance accuracy of the resulting construct which is better than that obtained using standard machining techniques.

  18. Automated 3D ultrasound measurement of the angle of progression in labor.

    PubMed

    Montaguti, Elisa; Rizzo, Nicola; Pilu, Gianluigi; Youssef, Aly

    2018-01-01

    To assess the feasibility and reliability of an automated technique for the assessment of the angle of progression (AoP) in labor by using three-dimensional (3D) ultrasound. AoP was assessed by using 3D transperineal ultrasound by two operators in 52 women in active labor to evaluate intra- and interobserver reproducibility. Furthermore, intermethod agreement between automated and manual techniques on 3D images, and between automated technique on 3D vs 2D images were evaluated. Automated measurements were feasible in all cases. Automated measurements were considered acceptable in 141 (90.4%) out of the 156 on the first assessments and in all 156 after repeating measurements for unacceptable evaluations. The automated technique on 3D images demonstrated good intra- and interobserver reproducibility. The 3D-automated technique showed a very good agreement with the 3D manual technique. Notably, AoP calculated with the 3D automated technique were significantly wider in comparison with those measured manually on 3D images (133 ± 17° vs 118 ± 21°, p = 0.013). The assessment of the angle of progression through 3D ultrasound is highly reproducible. However, automated software leads to a systematic overestimation of AoP in comparison with the standard manual technique thus hindering its use in clinical practice in its present form.

  19. Electrical bioimpedance and other techniques for gastric emptying and motility evaluation

    PubMed Central

    Huerta-Franco, María Raquel; Vargas-Luna, Miguel; Montes-Frausto, Juana Berenice; Flores-Hernández, Corina; Morales-Mata, Ismael

    2012-01-01

    The aim of this article is to identify non-invasive, inexpensive, highly sensitive and accurate techniques for evaluating and diagnosing gastric diseases. In the case of the stomach, there are highly sensitive and specific methods for assessing gastric motility and emptying (GME). However, these methods are invasive, expensive and/or not technically feasible for all clinicians and patients. We present a summary of the most relevant international information on non-invasive methods and techniques for clinically evaluating GME. We particularly emphasize the potential of gastric electrical bioimpedance (EBI). EBI was initially used mainly in gastric emptying studies and was essentially abandoned in favor of techniques such as electrogastrography and the gold standard, scintigraphy. The current research evaluating the utility of gastric EBI either combines this technique with other frequently used techniques or uses new methods for gastric EBI signal analysis. In this context, we discuss our results and those of other researchers who have worked with gastric EBI. In this review article, we present the following topics: (1) a description of the oldest methods and procedures for evaluating GME; (2) an explanation of the methods currently used to evaluate gastric activity; and (3) a perspective on the newest trends and techniques in clinical and research GME methods. We conclude that gastric EBI is a highly effective non-invasive, easy to use and inexpensive technique for assessing GME. PMID:22368782

  20. Chemically defined medium and Caenorhabditis elegans

    NASA Technical Reports Server (NTRS)

    Szewczyk, Nathaniel J.; Kozak, Elena; Conley, Catharine A.

    2003-01-01

    BACKGROUND: C. elegans has been established as a powerful genetic system. Use of a chemically defined medium (C. elegans Maintenance Medium (CeMM)) now allows standardization and systematic manipulation of the nutrients that animals receive. Liquid cultivation allows automated culturing and experimentation and should be of use in large-scale growth and screening of animals. RESULTS: We find that CeMM is versatile and culturing is simple. CeMM can be used in a solid or liquid state, it can be stored unused for at least a year, unattended actively growing cultures may be maintained longer than with standard techniques, and standard C. elegans protocols work well with animals grown in defined medium. We also find that there are caveats to using defined medium. Animals in defined medium grow more slowly than on standard medium, appear to display adaptation to the defined medium, and display altered growth rates as they change the composition of the defined medium. CONCLUSIONS: As was suggested with the introduction of C. elegans as a potential genetic system, use of defined medium with C. elegans should prove a powerful tool.

  1. An Integrated Power-Efficient Active Rectifier With Offset-Controlled High Speed Comparators for Inductively Powered Applications

    PubMed Central

    Lee, Hyung-Min; Ghovanloo, Maysam

    2011-01-01

    We present an active full-wave rectifier with offset-controlled high speed comparators in standard CMOS that provides high power conversion efficiency (PCE) in high frequency (HF) range for inductively powered devices. This rectifier provides much lower dropout voltage and far better PCE compared to the passive on-chip or off-chip rectifiers. The built-in offset-control functions in the comparators compensate for both turn-on and turn-off delays in the main rectifying switches, thus maximizing the forward current delivered to the load and minimizing the back current to improve the PCE. We have fabricated this active rectifier in a 0.5-μm 3M2P standard CMOS process, occupying 0.18 mm2 of chip area. With 3.8 V peak ac input at 13.56 MHz, the rectifier provides 3.12 V dc output to a 500 Ω load, resulting in the PCE of 80.2%, which is the highest measured at this frequency. In addition, overvoltage protection (OVP) as safety measure and built-in back telemetry capabilities have been incorporated in our design using detuning and load shift keying (LSK) techniques, respectively, and tested. PMID:22174666

  2. Multi-technique comparison of troposphere zenith delays and gradients during CONT08

    NASA Astrophysics Data System (ADS)

    Teke, Kamil; Böhm, Johannes; Nilsson, Tobias; Schuh, Harald; Steigenberger, Peter; Dach, Rolf; Heinkelmann, Robert; Willis, Pascal; Haas, Rüdiger; García-Espada, Susana; Hobiger, Thomas; Ichikawa, Ryuichi; Shimizu, Shingo

    2011-07-01

    CONT08 was a 15 days campaign of continuous Very Long Baseline Interferometry (VLBI) sessions during the second half of August 2008 carried out by the International VLBI Service for Geodesy and Astrometry (IVS). In this study, VLBI estimates of troposphere zenith total delays (ZTD) and gradients during CONT08 were compared with those derived from observations with the Global Positioning System (GPS), Doppler Orbitography and Radiopositioning Integrated by Satellite (DORIS), and water vapor radiometers (WVR) co-located with the VLBI radio telescopes. Similar geophysical models were used for the analysis of the space geodetic data, whereas the parameterization for the least-squares adjustment of the space geodetic techniques was optimized for each technique. In addition to space geodetic techniques and WVR, ZTD and gradients from numerical weather models (NWM) were used from the European Centre for Medium-Range Weather Forecasts (ECMWF) (all sites), the Japan Meteorological Agency (JMA) and Cloud Resolving Storm Simulator (CReSS) (Tsukuba), and the High Resolution Limited Area Model (HIRLAM) (European sites). Biases, standard deviations, and correlation coefficients were computed between the troposphere estimates of the various techniques for all eleven CONT08 co-located sites. ZTD from space geodetic techniques generally agree at the sub-centimetre level during CONT08, and—as expected—the best agreement is found for intra-technique comparisons: between the Vienna VLBI Software and the combined IVS solutions as well as between the Center for Orbit Determination (CODE) solution and an IGS PPP time series; both intra-technique comparisons are with standard deviations of about 3-6 mm. The best inter space geodetic technique agreement of ZTD during CONT08 is found between the combined IVS and the IGS solutions with a mean standard deviation of about 6 mm over all sites, whereas the agreement with numerical weather models is between 6 and 20 mm. The standard deviations are generally larger at low latitude sites because of higher humidity, and the latter is also the reason why the standard deviations are larger at northern hemisphere stations during CONT08 in comparison to CONT02 which was observed in October 2002. The assessment of the troposphere gradients from the different techniques is not as clear because of different time intervals, different estimation properties, or different observables. However, the best inter-technique agreement is found between the IVS combined gradients and the GPS solutions with standard deviations between 0.2 and 0.7 mm.

  3. Gender roles, family relationships, and household food and nutrition security in Ohafia matrilineal society in Nigeria.

    PubMed

    Ene-Obong, Henrietta Nkechi; Onuoha, Nne Ola; Eme, Paul Eze

    2017-11-01

    This study examined gender roles, family relationships, food security, and nutritional status of households in Ohafia: a matrilineal society in Nigeria. A cross-sectional descriptive study was conducted. Multistage sampling technique was used to select 287 households from three villages: Akanu, Amangwu, and Elu. Qualitative and quantitative data collection methods were adopted, namely, focus group discussions and questionnaires. Anthropometric measurements (height and weight for mothers and children and Mid-Upper Arm Circumference for young children) were taken using standard techniques. The body mass index of women was calculated. All nutritional indices were compared with reference standards. Food insecurity was assessed using the Household Hunger Scale and Dietary Diversity Score, then analysed using the Statistical Product for Service Solution version 21. Data analysis used descriptive statistics. Most (91.2%) of the respondents were female. The matrilineal system known as ikwu nne or iri ala a nne (inheritance through mothers' lineage) is still in place but is changing. One important benefit of the system is the access to land by women. Whereas women participated actively in agriculture, food preparation, and care of family, the men were moving to off-farm activities. High prevalence of household food insecurity (66%) and signs of malnutrition including moderate to severe stunting (48.4%) and wasting (31.7%) in children, household hunger (34.5%), and overweight (27.5%) and obesity (19.2%) among mothers were observed. These communities urgently need gender sensitive food and nutrition interventions. © 2018 John Wiley & Sons Ltd.

  4. Measurement of technetium-99 in Marshall Islands soil samples by ICP-MS

    PubMed

    Tagami; Uchida; Hamilton; Robison

    2000-07-01

    Extraction techniques for recovery of technetium-99 (99Tc) for Inductively Coupled Plasma Mass Spectrometry (ICP-MS) measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (MI) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for 99Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the 99Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The 99Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq g(-1) dry weight (dw). The limit of detection for 99Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq g(-1) dw under standard operating conditions.

  5. Clamp-crushing vs. radiofrequency-assisted liver resection:changes in liver function tests.

    PubMed

    Palibrk, Ivan; Milicic, Biljana; Stojiljkovic, Ljuba; Manojlovic, Nebojsa; Dugalic, Vladimir; Bumbasirevic, Vesna; Kalezic, Nevena; Zuvela, Marinko; Milicevic, Miroslav

    2012-05-01

    Liver resection is the gold standard in managing patients with metastatic or primary liver cancer. The aim of our study was to compare the traditional clamp-crushing technique to the radiofrequency- assisted liver resection technique in terms of postoperative liver function. Liver function was evaluated preoperatively and on postoperative days 3 and 7. Liver synthetic function parameters (serum albumin level, prothrombin time and international normalized ratio), markers of hepatic injury and necrosis (serum alanine aminotransferase, aspartate aminotransferase and total bilirubin level) and microsomal activity (quantitative lidocaine test) were compared. Forty three patients completed the study (14 had clamp-crushing and 29 had radiofrequency assisted liver resection). The groups did not differ in demographic characteristics, pre-operative liver function, operative time and perioperative transfusion rate. In postoperative period, there were similar changes in monitored parameters in both groups except albumin levels, that were higher in radiofrequency-assisted liver resection group (p=0.047). Both, traditional clamp-crushing technique and radiofrequency assisted liver resection technique, result in similar postoperative changes of most monitored liver function parameters.

  6. Utilizing Model Eliciting Activities (MEA's) to engage middle school teachers and students in storm water management practices to mitigate human impacts of land development

    NASA Astrophysics Data System (ADS)

    Tazaz, A.; Wilson, R. M.; Schoen, R.; Blumsack, S.; King, L.; Dyehouse, M.

    2013-12-01

    'The Integrating STEM Project' engaged 6-8 grade teachers through activities incorporating mathematics, science and technology incorporating both Next Generation Science Standards (NGSS) and Common Core State Standards-Mathematics (CCSS-Math). A group of researchers from Oceanography, Mathematics, and Education set out to provide middle school teachers with a 2 year intensive STEM integration professional development with a focus on environmental topics and to monitor the achievement outcomes in their students. Over the course of 2 years the researchers created challenging professional development sessions to expand teacher knowledge and teachers were tasked to transform the information gained during the professional development sessions for classroom use. One lesson resource kit presented to the teachers, which was directly applicable to the classroom, included Model Eliciting Activities (MEA's) to explore the positive and negative effects land development has on climate and the environment, and how land development impacts storm water management. MEA's were developed to encourage students to create models to solve complex problems and to allow teachers to investigate students thinking. MEA's are a great curriculum technique used in engineering fields to help engage students by providing hands on activities using real world data and problems. We wish to present the Storm Water Management Resource toolkit including the MEA and present the outcomes observed from student engagement in this activity.

  7. Carbohydrate linked organotin(IV) complexes as human topoisomerase Iα inhibitor and their antiproliferative effects against the human carcinoma cell line.

    PubMed

    Khan, Rais Ahmad; Yadav, Shipra; Hussain, Zahid; Arjmand, Farukh; Tabassum, Sartaj

    2014-02-14

    Dimethyltin(IV) complexes with ethanolamine (1) and biologically significant N-glycosides (2 and 3) were designed and synthesized. The structural elucidation of complexes 1-3 was done using elemental and spectroscopic methods; in addition, complex 1 was studied by single crystal X-ray diffraction studies. The in vitro DNA binding profile of complexes 2 and 3 was carried out by employing different biophysical methods to ascertain the feasibility of glycosylated complexes. Further, the cleaving ability of 2 and 3 was investigated by the agarose gel electrophoretic mobility assay with supercoiled pBR322 DNA, and demonstrated significantly good nuclease activity. Furthermore, both the complexes exhibited significant inhibitory effects on the catalytic activity of human Topo I at lower concentration than standard drugs. Computer-aided molecular docking techniques were used to ascertain the mode and mechanism of action towards the molecular target DNA and Topo I. The cytotoxicity of 2 and 3 against human hepatoma cancer cells (Huh7) was evaluated, which revealed significant regression in cancerous cells as compared with the standard drug. The antiproliferative activities of 2 and 3 were tested against human hepatoma cancer cells (Huh7), and results showed significantly good activity. Additionally, to validate the remarkable antiproliferative activity of complexes 2 and 3, specific regulatory gene expression (MMP-2 and TGF-β) was obtained by real time PCR.

  8. Tissue welding with virus-sterilized human cryoprecipitate

    NASA Astrophysics Data System (ADS)

    Williams, Matthew R.; Fras, Christian I.; Moscarelli, Richard D.; Libutti, Steven K.; Oz, Mehmet C.; Bass, Lawrence S.; Setton, Adrianne J.; Kaynar, Murat; Nowygrod, Roman; Treat, Michael R.

    1992-06-01

    Clinical use of laser tissue soldering with cryoprecipitate has been delayed by the fear of infecting recipients with donor viral products. Solvent-Detergent (S/D) treatment of human plasma is a technique for disrupting membrane enveloped viruses and rendering them noninfectious. Dual 6 cm incisions were created on the dorsum of nine rats and closed with either standard skin staples of with laser activated S/D cryoprecipitate. The animals were sacrificed at one of three time periods: 0, 2, and 4 days. The use of the laser tissue solder significantly improved tensile strength over standard skin closures at all time periods. Deactivation of viral particles during preparation of cryoprecipitate does not reduce the utility of this material as a solder during laser bonding. Reduced infectivity of S/D prepared products enhances their clinical utility.

  9. A Mobile Early Stimulation Program to Support Children with Developmental Delays in Brazil.

    PubMed

    Dias, Raquel da Luz; Silva, Kátia Cristina Correa Guimarães; Lima, Marcela Raquel de Oliveira; Alves, João Guilherme Bezerra; Abidi, Syed Sibte Raza

    2018-01-01

    Developmental delay is a deviation development from the normative milestones during the childhood and it may be caused by neurological disorders. Early stimulation is a standardized and simple technique to treat developmental delays in children (aged 0-3 years), allowing them to reach the best development possible and to mitigate neuropsychomotor sequelae. However, the outcomes of the treatment depending on the involvement of the family, to continue the activities at home on a daily basis. To empower and educate parents of children with neurodevelopmental delays to administer standardized early stimulation programs at home, we developed a mobile early stimulation program that provides timely and evidence-based clinical decision support to health professionals and a personalized guidance to parents about how to administer early stimulation to their child at home.

  10. Establishing Benchmarks for Outcome Indicators: A Statistical Approach to Developing Performance Standards.

    ERIC Educational Resources Information Center

    Henry, Gary T.; And Others

    1992-01-01

    A statistical technique is presented for developing performance standards based on benchmark groups. The benchmark groups are selected using a multivariate technique that relies on a squared Euclidean distance method. For each observation unit (a school district in the example), a unique comparison group is selected. (SLD)

  11. Radar cross sections of standard and complex shape targets

    NASA Technical Reports Server (NTRS)

    Sohel, M. S.

    1974-01-01

    The theoretical, analytical, and experimental results are described for radar cross sections (RCS) of different-shaped targets. Various techniques for predicting RCS are given, and RCS of finite standard targets are presented. Techniques used to predict the RCS of complex targets are made, and the RCS complex shapes are provided.

  12. Inexpensive Eddy-Current Standard

    NASA Technical Reports Server (NTRS)

    Berry, Robert F., Jr.

    1985-01-01

    Radial crack replicas serve as evaluation standards. Technique entails intimately joining two pieces of appropriate aluminum alloy stock and centering drilled hole through and along interface. Bore surface of hole presents two vertical stock interface lines 180 degrees apart. These lines serve as radial crack defect replicas during eddy-current technique setup and verification.

  13. Automated Inference of Chemical Discriminants of Biological Activity.

    PubMed

    Raschka, Sebastian; Scott, Anne M; Huertas, Mar; Li, Weiming; Kuhn, Leslie A

    2018-01-01

    Ligand-based virtual screening has become a standard technique for the efficient discovery of bioactive small molecules. Following assays to determine the activity of compounds selected by virtual screening, or other approaches in which dozens to thousands of molecules have been tested, machine learning techniques make it straightforward to discover the patterns of chemical groups that correlate with the desired biological activity. Defining the chemical features that generate activity can be used to guide the selection of molecules for subsequent rounds of screening and assaying, as well as help design new, more active molecules for organic synthesis.The quantitative structure-activity relationship machine learning protocols we describe here, using decision trees, random forests, and sequential feature selection, take as input the chemical structure of a single, known active small molecule (e.g., an inhibitor, agonist, or substrate) for comparison with the structure of each tested molecule. Knowledge of the atomic structure of the protein target and its interactions with the active compound are not required. These protocols can be modified and applied to any data set that consists of a series of measured structural, chemical, or other features for each tested molecule, along with the experimentally measured value of the response variable you would like to predict or optimize for your project, for instance, inhibitory activity in a biological assay or ΔG binding . To illustrate the use of different machine learning algorithms, we step through the analysis of a dataset of inhibitor candidates from virtual screening that were tested recently for their ability to inhibit GPCR-mediated signaling in a vertebrate.

  14. Standardization of chemical analytical techniques for pyrolysis bio-oil: history, challenges, and current status of methods

    DOE PAGES

    Ferrell, Jack R.; Olarte, Mariefel V.; Christensen, Earl D.; ...

    2016-07-05

    Here, we discuss the standardization of analytical techniques for pyrolysis bio-oils, including the current status of methods, and our opinions on future directions. First, the history of past standardization efforts is summarized, and both successful and unsuccessful validation of analytical techniques highlighted. The majority of analytical standardization studies to-date has tested only physical characterization techniques. In this paper, we present results from an international round robin on the validation of chemical characterization techniques for bio-oils. Techniques tested included acid number, carbonyl titrations using two different methods (one at room temperature and one at 80 °C), 31P NMR for determination ofmore » hydroxyl groups, and a quantitative gas chromatography–mass spectrometry (GC-MS) method. Both carbonyl titration and acid number methods have yielded acceptable inter-laboratory variabilities. 31P NMR produced acceptable results for aliphatic and phenolic hydroxyl groups, but not for carboxylic hydroxyl groups. As shown in previous round robins, GC-MS results were more variable. Reliable chemical characterization of bio-oils will enable upgrading research and allow for detailed comparisons of bio-oils produced at different facilities. Reliable analytics are also needed to enable an emerging bioenergy industry, as processing facilities often have different analytical needs and capabilities than research facilities. We feel that correlations in reliable characterizations of bio-oils will help strike a balance between research and industry, and will ultimately help to -determine metrics for bio-oil quality. Lastly, the standardization of additional analytical methods is needed, particularly for upgraded bio-oils.« less

  15. Standardization of chemical analytical techniques for pyrolysis bio-oil: history, challenges, and current status of methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ferrell, Jack R.; Olarte, Mariefel V.; Christensen, Earl D.

    Here, we discuss the standardization of analytical techniques for pyrolysis bio-oils, including the current status of methods, and our opinions on future directions. First, the history of past standardization efforts is summarized, and both successful and unsuccessful validation of analytical techniques highlighted. The majority of analytical standardization studies to-date has tested only physical characterization techniques. In this paper, we present results from an international round robin on the validation of chemical characterization techniques for bio-oils. Techniques tested included acid number, carbonyl titrations using two different methods (one at room temperature and one at 80 °C), 31P NMR for determination ofmore » hydroxyl groups, and a quantitative gas chromatography–mass spectrometry (GC-MS) method. Both carbonyl titration and acid number methods have yielded acceptable inter-laboratory variabilities. 31P NMR produced acceptable results for aliphatic and phenolic hydroxyl groups, but not for carboxylic hydroxyl groups. As shown in previous round robins, GC-MS results were more variable. Reliable chemical characterization of bio-oils will enable upgrading research and allow for detailed comparisons of bio-oils produced at different facilities. Reliable analytics are also needed to enable an emerging bioenergy industry, as processing facilities often have different analytical needs and capabilities than research facilities. We feel that correlations in reliable characterizations of bio-oils will help strike a balance between research and industry, and will ultimately help to -determine metrics for bio-oil quality. Lastly, the standardization of additional analytical methods is needed, particularly for upgraded bio-oils.« less

  16. Agricultural resources investigations in northern Italy and southern France, Agreste project. Part 1: Activity performed on the Italian test sites

    NASA Technical Reports Server (NTRS)

    1977-01-01

    The author has identified the following significant results. It was found that the standard atmospheric correction procedure cannot be successfully applied to water targets if a better correlation of MSS data with radiance input to LANDSAT sensors was not reached. It was confirmed that the six line effect must be avoided unless more sophisticated data handling techniques allow subtraction of various amounts of path radiance for the six satellite detectors. The COPTRAN program for atmospheric corrections of scan angle influence on atmospheric path was modified and completed. Six rice varieties were discriminated in proportions ranging from 65 percent to more than 80 percent. The same techniques were applied to poplar groves with a 70 percent precision.

  17. Optical fiber characteristics and standards; Proceedings of the Meeting, Cannes, France, November 25-27, 1985

    NASA Technical Reports Server (NTRS)

    Bouillie, Remy (Editor)

    1986-01-01

    Papers are presented on outside vapor deposition, the plasma activated CVD process for large scale production of telecommunication fibers, axial lateral plasma deposition technology from plastic clad silica, coatings for optical fibers, primary coating characterization, and radiation-induced time dependent attenuation in a fiber. Topics discussed include fibers with high tensile strength, the characteristics and specifications of airborne fiber optic components, the baseband frequency response of multimode fibers, and fibers for local and broadband networks. Consideration is given to industrial measurements for single mode and multimode fibers, the characterization of source power distribution in a multimode fiber by a splice offset technique, the measurement of chromatic dispersion in a single mode optical, and the effect of temperature on the refracted near-field optical fiber profiling technique.

  18. Visually guided tube thoracostomy insertion comparison to standard of care in a large animal model.

    PubMed

    Hernandez, Matthew C; Vogelsang, David; Anderson, Jeff R; Thiels, Cornelius A; Beilman, Gregory; Zielinski, Martin D; Aho, Johnathon M

    2017-04-01

    Tube thoracostomy (TT) is a lifesaving procedure for a variety of thoracic pathologies. The most commonly utilized method for placement involves open dissection and blind insertion. Image guided placement is commonly utilized but is limited by an inability to see distal placement location. Unfortunately, TT is not without complications. We aim to demonstrate the feasibility of a disposable device to allow for visually directed TT placement compared to the standard of care in a large animal model. Three swine were sequentially orotracheally intubated and anesthetized. TT was conducted utilizing a novel visualization device, tube thoracostomy visual trocar (TTVT) and standard of care (open technique). Position of the TT in the chest cavity were recorded using direct thoracoscopic inspection and radiographic imaging with the operator blinded to results. Complications were evaluated using a validated complication grading system. Standard descriptive statistical analyses were performed. Thirty TT were placed, 15 using TTVT technique, 15 using standard of care open technique. All of the TT placed using TTVT were without complication and in optimal position. Conversely, 27% of TT placed using standard of care open technique resulted in complications. Necropsy revealed no injury to intrathoracic organs. Visual directed TT placement using TTVT is feasible and non-inferior to the standard of care in a large animal model. This improvement in instrumentation has the potential to greatly improve the safety of TT. Further study in humans is required. Therapeutic Level II. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Development of Gold Standard Ion-Selective Electrode-Based Methods for Fluoride Analysis

    PubMed Central

    Martínez-Mier, E.A.; Cury, J.A.; Heilman, J.R.; Katz, B.P.; Levy, S.M.; Li, Y.; Maguire, A.; Margineda, J.; O’Mullane, D.; Phantumvanit, P.; Soto-Rojas, A.E.; Stookey, G.K.; Villa, A.; Wefel, J.S.; Whelton, H.; Whitford, G.M.; Zero, D.T.; Zhang, W.; Zohouri, V.

    2011-01-01

    Background/Aims: Currently available techniques for fluoride analysis are not standardized. Therefore, this study was designed to develop standardized methods for analyzing fluoride in biological and nonbiological samples used for dental research. Methods A group of nine laboratories analyzed a set of standardized samples for fluoride concentration using their own methods. The group then reviewed existing analytical techniques for fluoride analysis, identified inconsistencies in the use of these techniques and conducted testing to resolve differences. Based on the results of the testing undertaken to define the best approaches for the analysis, the group developed recommendations for direct and microdiffusion methods using the fluoride ion-selective electrode. Results Initial results demonstrated that there was no consensus regarding the choice of analytical techniques for different types of samples. Although for several types of samples, the results of the fluoride analyses were similar among some laboratories, greater differences were observed for saliva, food and beverage samples. In spite of these initial differences, precise and true values of fluoride concentration, as well as smaller differences between laboratories, were obtained once the standardized methodologies were used. Intraclass correlation coefficients ranged from 0.90 to 0.93, for the analysis of a certified reference material, using the standardized methodologies. Conclusion The results of this study demonstrate that the development and use of standardized protocols for F analysis significantly decreased differences among laboratories and resulted in more precise and true values. PMID:21160184

  20. Projected Standard on neutron skyshine. [Skyshine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Westfall, R.M.; Williams, D.S.

    1987-07-01

    Current interest in neutron skyshine arises from the application of dry fuel handling and storage techniques at reactor sites, at the proposed monitored retrievable storage facility and at other facilities being considered as part of the civilian radioactive waste management programs. The chairman of Standards Subcommittee ANS-6, Radiation Protection and Shielding, has requested that a work group be formed to characterize the neutron skyshine problem and, if necessary, prepare a draft Standard. The work group is comprised of representatives of storage cask vendors, architect engineering firms, nuclear utilities, the academic community and staff members of national laboratories and government agencies.more » The purpose of this presentation summary is to describe the activities of the work group and the scope and contents of the projected Standard, ANS-6.6.2, ''Calculation and Measurement of Direct and Scattered Neutron Radiation from Nuclear Power Operations.'' The specific source under consideration by the work group is an array of dry fuel casks located at a reactor site. However, it is recognized that the scope of the standard should be broad enough to encompass other neutron sources. The Standard will define appropriate methodology for properly characterizing the neutron dose due to skyshine. This dose characterization is necessary, for example, in demonstrating compliance with pertinent regulatory criteria.« less

  1. A novel technique for performing a tongue-lip adhesion-the tongue suspension technique.

    PubMed

    Mann, Robert J; Neaman, Keith C; Hill, Brian; Bajnrauh, Robert; Martin, Matthew D

    2012-01-01

    The tongue-lip adhesion has undergone several modifications in an attempt to reduce surgical complications and failure rates. Current techniques rely on the use of a button at the tongue base for suspension, which raises concerns about possible aspiration and interference with oral motor function and bottle-feeding. A new technique for tongue-lip adhesion is proposed that adds a tongue suspension to the standard surgical adhesion. A total of 22 patients with Pierre Robin sequence who received a tongue-lip adhesion via a tongue suspension technique were reviewed. The surgical technique differs from the standard surgical approach by the use of a suture weave across the base of the tongue instead of a standard button to suspend the tongue anteriorly. Average age at the time of tongue-lip adhesion was 13.9 days, with a mean operative time of 88.8 minutes. A marked improvement in postoperative oxygenation was seen in the majority of patients. One dehiscence occurred secondary to a traumatic postoperative extubation, eventually requiring a tracheostomy for subglottic stenosis. A technical innovation for performing a tongue-lip adhesion using a tongue suspension in conjunction with a standard transverse adhesion of the lip is described. The advantage of the tongue-lip adhesion with suspension includes immediate postoperative extubation, as well as removal of concerns regarding button aspiration and possible interference in early developmental oral motor function and bottle-feeding. This technique is reproducible, expanding the craniofacial surgeon's armamentarium for the management of difficult airways in Pierre Robin sequence.

  2. Residual anastomoses in twin-twin transfusion syndrome after laser: the Solomon randomized trial.

    PubMed

    Slaghekke, Femke; Lewi, Liesbeth; Middeldorp, Johanna M; Weingertner, Anne Sophie; Klumper, Frans J; Dekoninck, Philip; Devlieger, Roland; Lanna, Mariano M; Deprest, Jan; Favre, Romain; Oepkes, Dick; Lopriore, Enrico

    2014-09-01

    Residual anastomoses after fetoscopic laser surgery for twin-to-twin transfusion syndrome (TTTS) may lead to severe postoperative complications, including recurrent TTTS and twin anemia-polycythemia sequence (TAPS). A novel technique (Solomon technique) using laser coagulation of the entire vascular equator was recently investigated in a randomized controlled trial (Solomon trial) and compared with the Standard selective laser technique. The aim of this secondary analysis was to evaluate the occurrence and characteristics of residual anastomoses in placentas included in the Solomon trial. International multicenter randomized controlled trial in TTTS, randomized 1:1 ratio to either the Solomon laser technique or Standard laser technique. At time of laser, surgeons recorded whether they considered the procedure to be complete. Placental dye injection was performed after birth in the participating centers to evaluate the presence of residual anastomoses. A total of 151 placentas were included in the study. The percentage of placentas with residual anastomoses in the Solomon group and Standard group was 19% (14/74) and 34% (26/77), respectively (P = .04). The percentage of placentas with residual anastomoses in the subgroup of cases where the procedure was recorded as complete was 8/65 (12%) and 22/69 (32%) in the Solomon group and Standard group, respectively (P < .01). The Solomon laser technique reduces the risk of residual anastomoses. However, careful follow-up remains essential also after the Solomon technique, as complete dichorionization is not always achieved. Copyright © 2014 Mosby, Inc. All rights reserved.

  3. Placement of empty catheters for an HDR-emulating LDR prostate brachytherapy technique: comparison to standard intraoperative planning.

    PubMed

    Niedermayr, Thomas R; Nguyen, Paul L; Murciano-Goroff, Yonina R; Kovtun, Konstantin A; Neubauer Sugar, Emily; Cail, Daniel W; O'Farrell, Desmond A; Hansen, Jorgen L; Cormack, Robert A; Buzurovic, Ivan; Wolfsberger, Luciant T; O'Leary, Michael P; Steele, Graeme S; Devlin, Philip M; Orio, Peter F

    2014-01-01

    We sought to determine whether placing empty catheters within the prostate and then inverse planning iodine-125 seed locations within those catheters (High Dose Rate-Emulating Low Dose Rate Prostate Brachytherapy [HELP] technique) would improve concordance between planned and achieved dosimetry compared with a standard intraoperative technique. We examined 30 consecutive low dose rate prostate cases performed by standard intraoperative technique of planning followed by needle placement/seed deposition and compared them to 30 consecutive low dose rate prostate cases performed by the HELP technique. The primary endpoint was concordance between planned percentage of the clinical target volume that receives at least 100% of the prescribed dose/dose that covers 90% of the volume of the clinical target volume (V100/D90) and the actual V100/D90 achieved at Postoperative Day 1. The HELP technique had superior concordance between the planned target dosimetry and what was actually achieved at Day 1 and Day 30. Specifically, target D90 at Day 1 was on average 33.7 Gy less than planned for the standard intraoperative technique but was only 10.5 Gy less than planned for the HELP technique (p < 0.001). Day 30 values were 16.6 Gy less vs. 2.2 Gy more than planned, respectively (p = 0.028). Day 1 target V100 was 6.3% less than planned with standard vs. 2.8% less for HELP (p < 0.001). There was no significant difference between the urethral and rectal concordance (all p > 0.05). Placing empty needles first and optimizing the plan to the known positions of the needles resulted in improved concordance between the planned and the achieved dosimetry to the target, possibly because of elimination of errors in needle placement. Copyright © 2014 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  4. Electromagnetic navigation reduces surgical time and radiation exposure for proximal interlocking in retrograde femoral nailing.

    PubMed

    Somerson, Jeremy S; Rowley, David; Kennedy, Chad; Buttacavoli, Frank; Agarwal, Animesh

    2014-07-01

    To compare the time required for proximal locking screw placement between a standard freehand technique and the navigated technique, and to quantify the reduction in ionizing radiation exposure. A fresh frozen cadaver model was used for 48 proximal interlocking screw procedures. Each procedure consisted of insertion of 2 anteroposterior locking screws. Standard fluoroscopic technique was used for 24 procedures, and an electromagnetic navigation system was used for the remaining 24 procedures. Procedure duration was recorded using an electronic timer and radiation doses were documented. Mean total insertion time for both proximal interlocking screws was 405 ± 165.7 seconds with the freehand technique and 311 ± 78.3 seconds in the navigation group (P = 0.002). All procedures resulted in successful locking screw placement. Mean ionizing radiation exposure time for proximal locking was 29.5 ± 12.8 seconds. Proximal locking screw insertion using the navigation technique evaluated in this work was significantly faster than the standard fluoroscopic method. The navigated technique is effective and has the potential to prevent ionizing radiation exposure.

  5. The use of an active learning approach in a SCALE-UP learning space improves academic performance in undergraduate General Biology.

    PubMed

    Hacisalihoglu, Gokhan; Stephens, Desmond; Johnson, Lewis; Edington, Maurice

    2018-01-01

    Active learning is a pedagogical approach that involves students engaging in collaborative learning, which enables them to take more responsibility for their learning and improve their critical thinking skills. While prior research examined student performance at majority universities, this study focuses on specifically Historically Black Colleges and Universities (HBCUs) for the first time. Here we present work that focuses on the impact of active learning interventions at Florida A&M University, where we measured the impact of active learning strategies coupled with a SCALE-UP (Student Centered Active Learning Environment with Upside-down Pedagogies) learning environment on student success in General Biology. In biology sections where active learning techniques were employed, students watched online videos and completed specific activities before class covering information previously presented in a traditional lecture format. In-class activities were then carefully planned to reinforce critical concepts and enhance critical thinking skills through active learning techniques such as the one-minute paper, think-pair-share, and the utilization of clickers. Students in the active learning and control groups covered the same topics, took the same summative examinations and completed identical homework sets. In addition, the same instructor taught all of the sections included in this study. Testing demonstrated that these interventions increased learning gains by as much as 16%, and students reported an increase in their positive perceptions of active learning and biology. Overall, our results suggest that active learning approaches coupled with the SCALE-UP environment may provide an added opportunity for student success when compared with the standard modes of instruction in General Biology.

  6. Neutron activation measurements over an extremely wide dynamic range (invited) (abstract)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barnes, C.W.

    1997-01-01

    The DT program at the Tokamak Fusion Test Reactor (TFTR) created requirements on 14 MeV neutron measurements to measure from 10{sup 6} n/cm{sup 2} (for triton burnup and Ohmic tritium plasmas) to {gt}10{sup 12} n/cm{sup 2} (characteristic of {gt}10 MW DT plasmas) with an accuracy of 7% (one-sigma).1 To maintain an absolute calibration over this dynamic range with active neutron detectors required one to go from some absolute standard at one fluence level to a measurement at a much higher fluence. Maintaining accuracy requires an extremely linear set of measurements not systematically affected over this dynamic range. Neutron activation canmore » provide such linearity when care is taken with a number of effects such as gamma-ray detection efficiency and sample contamination.2 Absolutely calibrated neutron yield measurements using dosimetric (well-known cross section) reactions with thin (low-mass) elemental foils is be described. This technique makes the detector comparison to an absolute standard of gamma-ray activity correspond to all neutron fluences by reducing the sample mass while keeping the activation detectors operating in a linear counting mode; i.e., low count rates which minimize pileup effects. The International Thermonuclear Experimental Reactor is projected to have 1000 s burn durations at fluxes of few 10{sup 13} n/cm{sup 2}s, or more neutron fluence {ital per second} than entire TFTR discharges. Extrapolating neutron activation to these higher fluences will require yet more care. Some of the issues at such high fluences will be discussed.3 The National Ignition Facility (NIF) is projected to yield 10 MJ of fusion energy, or up to 10{sup 12} n/cm{sup 2} at the vacuum vessel wall, similar to TFTR DT conditions. It is expected that much interesting physics will be performed at yields far less than those from ignition, covering an even greater dynamic range than needed on TFTR. Thin foil techniques do not have the sensitivity required at low fluences.« less

  7. Thermosonication and optimization of stingless bee honey processing.

    PubMed

    Chong, K Y; Chin, N L; Yusof, Y A

    2017-10-01

    The effects of thermosonication on the quality of a stingless bee honey, the Kelulut, were studied using processing temperature from 45 to 90 ℃ and processing time from 30 to 120 minutes. Physicochemical properties including water activity, moisture content, color intensity, viscosity, hydroxymethylfurfural content, total phenolic content, and radical scavenging activity were determined. Thermosonication reduced the water activity and moisture content by 7.9% and 16.6%, respectively, compared to 3.5% and 6.9% for conventional heating. For thermosonicated honey, color intensity increased by 68.2%, viscosity increased by 275.0%, total phenolic content increased by 58.1%, and radical scavenging activity increased by 63.0% when compared to its raw form. The increase of hydroxymethylfurfural to 62.46 mg/kg was still within the limits of international standards. Optimized thermosonication conditions using response surface methodology were predicted at 90 ℃ for 111 minutes. Thermosonication was revealed as an effective alternative technique for honey processing.

  8. Flexible and Accessible Automated Operation of Miniature Chromatography Columns on a Liquid Handling Station.

    PubMed

    Konstantinidis, Spyridon; Goh, Hai-Yuan; Martin Bufájer, José M; de Galbert, Paul; Parau, Maria; Velayudhan, Ajoy

    2018-03-01

    The High Throughput (HT) investigation of chromatographic separations is an important element of downstream bioprocess development due to the importance of chromatography as a technique for achieving stringent regulatory requirements on product purity. Various HT formats for chromatography exist, but the miniature column approach has characteristics resembling large scale packed bed column chromatography the most. The operation of such columns on robotic stations can be automated, but this is not always a straightforward procedure; the robotic manipulations are highly dependent on the settings of each experiment and the standard commands of the supporting software may not provide readily the required flexibility and accessibility for "plug and play" functionality. These can limit the potential of this technique in laboratories engaging on HT activities. In this work, we present an application which aims to overcome this challenge by providing end-users with a flexible operation of the miniature column technique on an automated liquid handler. The application includes a script which is written on Freedom EVOware, and is supplemented by custom compiled executables. Here, the manipulations carried out by the application are described in detail and its functionality is demonstrated through typical experiments based on bind and elute miniature column chromatography. The application is shown to allow for the unsupervised "on-the-fly" programming of the robotic station and to ultimately make the technique accessible to non-automation experts. This application is therefore well suited to simplifying development activities based on the robotic deployment of the miniature column chromatography technique. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Measures of outdoor play and independent mobility in children and youth: A methodological review.

    PubMed

    Bates, Bree; Stone, Michelle R

    2015-09-01

    Declines in children's outdoor play have been documented globally, which are partly due to heightened restrictions around children's independent mobility. Literature on outdoor play and children's independent mobility is increasing, yet no paper has summarized the various methodological approaches used. A methodological review could highlight most commonly used measures and comprehensive research designs that could result in more standardized methodological approaches. Methodological review. A standardized protocol guided a methodological review of published research on measures of outdoor play and children's independent mobility in children and youth (0-18 years). Online searches of 8 electronic databases were conducted and studies included if they contained a subjective/objective measure of outdoor play or children's independent mobility. References of included articles were scanned to identify additional articles. Twenty-four studies were included on outdoor play, and twenty-three on children's independent mobility. Study designs were diverse. Common objective measures included accelerometry, global positioning systems and direct observation; questionnaires, surveys and interviews were common subjective measures. Focus groups, activity logs, monitoring sheets, travel/activity diaries, behavioral maps and guided tours were also utilized. Questionnaires were used most frequently, yet few studies used the same questionnaire. Five studies employed comprehensive, mixed-methods designs. Outdoor play and children's independent mobility have been measured using a wide variety of techniques, with only a few studies using similar methodologies. A standardized methodological approach does not exist. Future researchers should consider including both objective measures (accelerometry and global positioning systems) and subjective measures (questionnaires, activity logs, interviews), as more comprehensive designs will enhance understanding of each multidimensional construct. Creating a standardized methodological approach would improve study comparisons. Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  10. Hyperinsulinemic Normoglycemia does not meaningfully improve Myocardial Performance during Cardiac Surgery: A Randomized Trial

    PubMed Central

    Duncan, Andra E.; Kashy, Babak Kateby; Sarwar, Sheryar; Singh, Akhil; Stenina-Adognravi, Olga; Christoffersen, Steffen; Alfirevic, Andrej; Sale, Shiva; Yang, Dongsheng; Thomas, James D.; Gillinov, Marc; Sessler, Daniel I.

    2015-01-01

    Background Glucose-insulin-potassium (GIK) administration during cardiac surgery inconsistently improves myocardial function, perhaps because hyperglycemia negates the beneficial effects of GIK. The hyperinsulinemic normoglycemic clamp (HNC) technique may better enhance the myocardial benefits of GIK. We extended previous GIK investigations by: 1) targeting normoglycemia while administering a glucose-insulin-potassium infusion (HNC); 2) using improved echocardiographic measures of myocardial deformation, specifically myocardial longitudinal strain and strain rate; and, 3) assessing activation of glucose metabolic pathways. Methods 100 patients having aortic valve replacement for aortic stenosis were randomly assigned to HNC (high-dose insulin with concomitant glucose infusion titrated to normoglycemia) versus standard therapy (insulin treatment if glucose >150 mg/dL). Our primary outcomes were left ventricular longitudinal strain and strain rate, assessed using speckle-tracking echocardiography. Right atrial tissue was analyzed for activation of glycolysis/pyruvate oxidation and alternative metabolic pathways. Results Time-weighted mean glucose concentrations were lower with HNC (127±19 mg/dL) than standard care (177±41 mg/dL; P<0.001). Echocardiographic data were adequate in 72 patients for strain analysis and 67 patients for strain rate analysis. HNC did not improve myocardial strain, with an HNC minus standard therapy difference of −1.2 (97.5%CI: −2.9, 0.5)%; P=0.11. Strain rate was significantly better, but by a clinically unimportant amount: −0.16 (−0.30, −0.03) sec−1, P = 0.007. There was no evidence of increased glycolytic, pyruvate oxidation, or hexosamine biosynthetic pathway activation in right atrial samples (n = 20, HNC; 22, standard therapy). Conclusions Administration of glucose and insulin while targeting normoglycemia during aortic valve replacement did not meaningfully improve myocardial function. PMID:26200180

  11. Superresolution imaging of Drosophila tissues using expansion microscopy.

    PubMed

    Jiang, Nan; Kim, Hyeon-Jin; Chozinski, Tyler J; Azpurua, Jorge E; Eaton, Benjamin A; Vaughan, Joshua C; Parrish, Jay Z

    2018-06-15

    The limited resolving power of conventional diffraction-limited microscopy hinders analysis of small, densely packed structural elements in cells. Expansion microscopy (ExM) provides an elegant solution to this problem, allowing for increased resolution with standard microscopes via physical expansion of the specimen in a swellable polymer hydrogel. Here, we apply, validate, and optimize ExM protocols that enable the study of Drosophila embryos, larval brains, and larval and adult body walls. We achieve a lateral resolution of ∼70 nm in Drosophila tissues using a standard confocal microscope, and we use ExM to analyze fine intracellular structures and intercellular interactions. First, we find that ExM reveals features of presynaptic active zone (AZ) structure that are observable with other superresolution imaging techniques but not with standard confocal microscopy. We further show that synapses known to exhibit age-dependent changes in activity also exhibit age-dependent changes in AZ structure. Finally, we use the significantly improved axial resolution of ExM to show that dendrites of somatosensory neurons are inserted into epithelial cells at a higher frequency than previously reported in confocal microscopy studies. Altogether, our study provides a foundation for the application of ExM to Drosophila tissues and underscores the importance of tissue-specific optimization of ExM procedures.

  12. Evaluation of the laser-induced breakdown spectroscopy technique for determination of the chemical composition of copper concentrates

    NASA Astrophysics Data System (ADS)

    Łazarek, Łukasz; Antończak, Arkadiusz J.; Wójcik, Michał R.; Drzymała, Jan; Abramski, Krzysztof M.

    2014-07-01

    Laser-induced breakdown spectroscopy (LIBS), like many other spectroscopic techniques, is a comparative method. Typically, in qualitative analysis, synthetic certified standard with a well-known elemental composition is used to calibrate the system. Nevertheless, in all laser-induced techniques, such calibration can affect the accuracy through differences in the overall composition of the chosen standard. There are also some intermediate factors, which can cause imprecision in measurements, such as optical absorption, surface structure and thermal conductivity. In this work the calibration performed for the LIBS technique utilizes pellets made directly from the tested materials (old well-characterized samples). This choice produces a considerable improvement in the accuracy of the method. This technique was adopted for the determination of trace elements in industrial copper concentrates, standardized by conventional atomic absorption spectroscopy with a flame atomizer. A series of copper flotation concentrate samples was analyzed for three elements: silver, cobalt and vanadium. We also proposed a method of post-processing the measurement data to minimize matrix effects and permit reliable analysis. It has been shown that the described technique can be used in qualitative and quantitative analyses of complex inorganic materials, such as copper flotation concentrates. It was noted that the final validation of such methodology is limited mainly by the accuracy of the characterization of the standards.

  13. Investigation of interpolation techniques for the reconstruction of the first dimension of comprehensive two-dimensional liquid chromatography-diode array detector data.

    PubMed

    Allen, Robert C; Rutan, Sarah C

    2011-10-31

    Simulated and experimental data were used to measure the effectiveness of common interpolation techniques during chromatographic alignment of comprehensive two-dimensional liquid chromatography-diode array detector (LC×LC-DAD) data. Interpolation was used to generate a sufficient number of data points in the sampled first chromatographic dimension to allow for alignment of retention times from different injections. Five different interpolation methods, linear interpolation followed by cross correlation, piecewise cubic Hermite interpolating polynomial, cubic spline, Fourier zero-filling, and Gaussian fitting, were investigated. The fully aligned chromatograms, in both the first and second chromatographic dimensions, were analyzed by parallel factor analysis to determine the relative area for each peak in each injection. A calibration curve was generated for the simulated data set. The standard error of prediction and percent relative standard deviation were calculated for the simulated peak for each technique. The Gaussian fitting interpolation technique resulted in the lowest standard error of prediction and average relative standard deviation for the simulated data. However, upon applying the interpolation techniques to the experimental data, most of the interpolation methods were not found to produce statistically different relative peak areas from each other. While most of the techniques were not statistically different, the performance was improved relative to the PARAFAC results obtained when analyzing the unaligned data. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. Practical no-gold-standard evaluation framework for quantitative imaging methods: application to lesion segmentation in positron emission tomography

    PubMed Central

    Jha, Abhinav K.; Mena, Esther; Caffo, Brian; Ashrafinia, Saeed; Rahmim, Arman; Frey, Eric; Subramaniam, Rathan M.

    2017-01-01

    Abstract. Recently, a class of no-gold-standard (NGS) techniques have been proposed to evaluate quantitative imaging methods using patient data. These techniques provide figures of merit (FoMs) quantifying the precision of the estimated quantitative value without requiring repeated measurements and without requiring a gold standard. However, applying these techniques to patient data presents several practical difficulties including assessing the underlying assumptions, accounting for patient-sampling-related uncertainty, and assessing the reliability of the estimated FoMs. To address these issues, we propose statistical tests that provide confidence in the underlying assumptions and in the reliability of the estimated FoMs. Furthermore, the NGS technique is integrated within a bootstrap-based methodology to account for patient-sampling-related uncertainty. The developed NGS framework was applied to evaluate four methods for segmenting lesions from F-Fluoro-2-deoxyglucose positron emission tomography images of patients with head-and-neck cancer on the task of precisely measuring the metabolic tumor volume. The NGS technique consistently predicted the same segmentation method as the most precise method. The proposed framework provided confidence in these results, even when gold-standard data were not available. The bootstrap-based methodology indicated improved performance of the NGS technique with larger numbers of patient studies, as was expected, and yielded consistent results as long as data from more than 80 lesions were available for the analysis. PMID:28331883

  15. Laparoendoscopic Single-Site Cholecystectomy: First Experiences with a New Standardized Technique Replicating the Four-Port Technique.

    PubMed

    Morales-Conde, Salvador; Cañete-Gómez, Jesús; Gómez, Virginia; Socas Macías, María; Moreno, Antonio Barranco; Del Agua, Isaias Alarcón; Ruíz, Francisco Javier Padillo

    2016-10-01

    After reports on laparoendoscopic single-site (LESS) cholecystectomy, concerns have been raised over the level of difficulty and a potential increase in complications when moving away from conventional gold standard multiport laparoscopy due to incomplete exposure and larger umbilical incisions. With continued development of technique and technology, it has now become possible to fully replicate this gold standard procedure through an LESS approach. First experiences with the newly developed technique and instrument are reported. Fifteen patients presenting with cholelithiasis without signs of inflammation were operated using all surgical steps considered appropriate for the conventional four-port laparoscopic approach, but applied through a single access device. Operation-centered outcomes are presented. There were no peri- or postoperative complications. Mean operating time was 32.3 minutes. No conversion to regular laparoscopy was required. The critical view of safety was achieved in all cases. Mean skin incision length was 2.2 cm. The application of a standardized technique combined with the use of a four-port LESS device allows us to perform LESS cholecystectomy, giving us a correct exposure of the structures and without increasing the mean operating time combining previously reported advantages of LESS. A universal trait of any new technique should be safety and reproducibility. This will enhance its applicability by large number of surgeons and to large number of patients requiring cholecystectomy.

  16. Radiation Protection. Measurement of radioactivity in the environment - Air- radon 222. A proposed ISO standard.

    NASA Astrophysics Data System (ADS)

    Gillmore, G.; Woods, M.

    2009-04-01

    Radon isotopes (222, 220, 219) are radioactive gases produced by the disintegration of radium isotopes 226, 224 and 223, which are decay products of uranium238, thorium232 and uranium235 respectively. All are found in the earth's crust. Solid elements, also radioactive, are produced by radon disintegration. Radon is classed as a rare gas in the periodic table of elements, along with helium, argon, neon, krypton and xenon. When disintegrating, radon emits alpha particles and generates solid decay products, which are also radioactive (polonium, bismuth, lead etc.). The potential danger of radon lies in its solid decay products rather than the gas itself. Whether or not they are attached aerosols, radon decay products can be inhaled and deposited in the bronchopulmonary tree to varying depths according to their size. Radon today is considered to be the main source of human exposure to natural radiation. At the international level, radon accounts for 52% of global average exposure to natural radiation. Isotope 222 (48%) is far more significant than isotope 220 (4%), whilst isotope 219 is considered as negligible. Exposure to radon varies considerably from one region to another, depending on factors such as weather conditions, and underlying geology. Activity concentration can therefore vary by a factor of 10 or even a 100 from one period of time to the next and from one area to another. There are many ways of measuring the radon 222 activity concentration and the potential alpha energy concentration of its short-lived decay products. Measuring techniques fall into three categories: - spot measurement methods; continuous measurement; integrated measurement. The proposed ISO (International Organisation for Standardisation) document suggests guidelines for measuring radon222 activity concentration and the potential alpha energy concentration of its short-lived decay products in a free (environment) and confined (buildings) atmosphere. The target date for availability of this work item is 2011. The ISO document here highlighted is a working draft. ISO is a worldwide federation of national standards bodies. Keywords: radon; international standards; measurement techniques.

  17. An analysis of fracture trace patterns in areas of flat-lying sedimentary rocks for the detection of buried geologic structure. [Kansas and Texas

    NASA Technical Reports Server (NTRS)

    Podwysocki, M. H.

    1974-01-01

    Two study areas in a cratonic platform underlain by flat-lying sedimentary rocks were analyzed to determine if a quantitative relationship exists between fracture trace patterns and their frequency distributions and subsurface structural closures which might contain petroleum. Fracture trace lengths and frequency (number of fracture traces per unit area) were analyzed by trend surface analysis and length frequency distributions also were compared to a standard Gaussian distribution. Composite rose diagrams of fracture traces were analyzed using a multivariate analysis method which grouped or clustered the rose diagrams and their respective areas on the basis of the behavior of the rays of the rose diagram. Analysis indicates that the lengths of fracture traces are log-normally distributed according to the mapping technique used. Fracture trace frequency appeared higher on the flanks of active structures and lower around passive reef structures. Fracture trace log-mean lengths were shorter over several types of structures, perhaps due to increased fracturing and subsequent erosion. Analysis of rose diagrams using a multivariate technique indicated lithology as the primary control for the lower grouping levels. Groupings at higher levels indicated that areas overlying active structures may be isolated from their neighbors by this technique while passive structures showed no differences which could be isolated.

  18. Deflection-Based Aircraft Structural Loads Estimation with Comparison to Flight

    NASA Technical Reports Server (NTRS)

    Lizotte, Andrew M.; Lokos, William A.

    2005-01-01

    Traditional techniques in structural load measurement entail the correlation of a known load with strain-gage output from the individual components of a structure or machine. The use of strain gages has proved successful and is considered the standard approach for load measurement. However, remotely measuring aerodynamic loads using deflection measurement systems to determine aeroelastic deformation as a substitute to strain gages may yield lower testing costs while improving aircraft performance through reduced instrumentation weight. With a reliable strain and structural deformation measurement system this technique was examined. The objective of this study was to explore the utility of a deflection-based load estimation, using the active aeroelastic wing F/A-18 aircraft. Calibration data from ground tests performed on the aircraft were used to derive left wing-root and wing-fold bending-moment and torque load equations based on strain gages, however, for this study, point deflections were used to derive deflection-based load equations. Comparisons between the strain-gage and deflection-based methods are presented. Flight data from the phase-1 active aeroelastic wing flight program were used to validate the deflection-based load estimation method. Flight validation revealed a strong bending-moment correlation and slightly weaker torque correlation. Development of current techniques, and future studies are discussed.

  19. Assessment of the global fallout of plutonium isotopes and americium-241 in the soil of the central region of Saudi Arabia.

    PubMed

    Shabana, E I; Al-Shammari, H L

    2001-01-01

    A radiochemical technique for determination of plutonium isotopes and 241Am in soil samples is tested against IAEA-standard reference materials to determine its accuracy and precision for reliable results. The technique is then used in the investigation of topsoil samples, collected from the natural environment of the central region of Saudi Arabia, to assess the effect of fallout accumulation of these radionuclides in the region. Plutonium and americium were sequentially separated from all other components of the sample by anion-exchange chromatography and co-precipitated with Nd3+ as fluorides. The precipitates were mounted on membrane filters and measured using a high-resolution alpha-spectrometer. The results of the analysis of the reference materials showed satisfactory sensitivity and precision of the technique. The results of the analyzed soil samples show activity levels ranging from < LLD to 0.089 and from

  20. The separation of 99Tc from low and medium-level radioactive wastes and its determination by inductively coupled plasma mass spectrometry.

    PubMed

    Hepiegne, P; Dall'ava, D; Clement, R; Degros, J P

    1995-06-01

    A chemical separation method has been developed for the determination of (99)Tc in various types of radioactive wastes. Such a method includes (i) fusion with NaOH, (ii) extraction in a column containing methyltrioctylammonium chloride, (iii) extraction by solvent with N-benzoyl-N-phenylhydroxylamine and, (iv) measurement by inductively-coupled plasma mass spectrometry (ICP-MS). From the performance standpoint, the recovery of (99)Tc, using (99m)Tc as a yield tracer, is higher than 70%. This analytical method, as developed, ensures effective decontamination with respect to the radionuclides, insofar the decontamination factors are greater than 10(+5), whenever the residual activity may be measured. Taking into account a 3sigma counting error, the detection limit obtained with the ICP-MS technique is 1.9 mBq/ml; the method enabling hence to detect activities as low as 0.3 Bq/g, with analysed samples of 0.2 g and a radiochemical yield of 70%. Studies have been dedicated to the (99)Tc measurement, using the electrothermal vaporization ICP-MS technique, which lowers the detection limit by a factor 10, with the standard solution (0.3 pg/ml), compared with the previous ICP-MS technique.

  1. Performance of Optimized Actuator and Sensor Arrays in an Active Noise Control System

    NASA Technical Reports Server (NTRS)

    Palumbo, D. L.; Padula, S. L.; Lyle, K. H.; Cline, J. H.; Cabell, R. H.

    1996-01-01

    Experiments have been conducted in NASA Langley's Acoustics and Dynamics Laboratory to determine the effectiveness of optimized actuator/sensor architectures and controller algorithms for active control of harmonic interior noise. Tests were conducted in a large scale fuselage model - a composite cylinder which simulates a commuter class aircraft fuselage with three sections of trim panel and a floor. Using an optimization technique based on the component transfer functions, combinations of 4 out of 8 piezoceramic actuators and 8 out of 462 microphone locations were evaluated against predicted performance. A combinatorial optimization technique called tabu search was employed to select the optimum transducer arrays. Three test frequencies represent the cases of a strong acoustic and strong structural response, a weak acoustic and strong structural response and a strong acoustic and weak structural response. Noise reduction was obtained using a Time Averaged/Gradient Descent (TAGD) controller. Results indicate that the optimization technique successfully predicted best and worst case performance. An enhancement of the TAGD control algorithm was also evaluated. The principal components of the actuator/sensor transfer functions were used in the PC-TAGD controller. The principal components are shown to be independent of each other while providing control as effective as the standard TAGD.

  2. Determination of the rare-earth elements in geological materials by inductively coupled plasma mass spectrometry

    USGS Publications Warehouse

    Lichte, F.E.; Meier, A.L.; Crock, J.G.

    1987-01-01

    A method of analysis of geological materials for the determination of the rare-earth elements using the Inductively coupled plasma mass spectrometric technique (ICP-MS) has been developed. Instrumental parameters and factors affecting analytical results have been first studied and then optimized. Samples are analyzed directly following an acid digestion, without the need for separation or preconcentration with limits of detection of 2-11 ng/g, precision of ?? 2.5% relative standard deviation, and accuracy comparable to inductively coupled plasma emission spectrometry and instrumental neutron activation analysis. A commercially available ICP-MS instrument is used with modifications to the sample introduction system, torch, and sampler orifice to reduce the effects of high salt content of sample solutions prepared from geologic materials. Corrections for isobaric interferences from oxide ions and other diatomic and triatomic ions are made mathematically. Special internal standard procedures are used to compensate for drift in metahmetal oxide ratios and sensitivity. Reference standard values are used to verify the accuracy and utility of the method.

  3. Improved localization accuracy in stochastic super-resolution fluorescence microscopy by K-factor image deshadowing

    PubMed Central

    Ilovitsh, Tali; Meiri, Amihai; Ebeling, Carl G.; Menon, Rajesh; Gerton, Jordan M.; Jorgensen, Erik M.; Zalevsky, Zeev

    2013-01-01

    Localization of a single fluorescent particle with sub-diffraction-limit accuracy is a key merit in localization microscopy. Existing methods such as photoactivated localization microscopy (PALM) and stochastic optical reconstruction microscopy (STORM) achieve localization accuracies of single emitters that can reach an order of magnitude lower than the conventional resolving capabilities of optical microscopy. However, these techniques require a sparse distribution of simultaneously activated fluorophores in the field of view, resulting in larger time needed for the construction of the full image. In this paper we present the use of a nonlinear image decomposition algorithm termed K-factor, which reduces an image into a nonlinear set of contrast-ordered decompositions whose joint product reassembles the original image. The K-factor technique, when implemented on raw data prior to localization, can improve the localization accuracy of standard existing methods, and also enable the localization of overlapping particles, allowing the use of increased fluorophore activation density, and thereby increased data collection speed. Numerical simulations of fluorescence data with random probe positions, and especially at high densities of activated fluorophores, demonstrate an improvement of up to 85% in the localization precision compared to single fitting techniques. Implementing the proposed concept on experimental data of cellular structures yielded a 37% improvement in resolution for the same super-resolution image acquisition time, and a decrease of 42% in the collection time of super-resolution data with the same resolution. PMID:24466491

  4. Two Primary Standards for Low Flows of Gases

    PubMed Central

    Berg, Robert F.; Tison, Stuart A.

    2004-01-01

    We describe two primary standards for gas flow in the range from 0.1 to 1000 μmol/s. (1 μmol/s ≅ 1.3 cm3/min at 0 °C and 1 atmosphere.) The first standard is a volumetric technique in which measurements of pressure, volume, temperature, and time are recorded while gas flows in or out of a stainless steel bellows at constant pressure. The second standard is a gravimetric technique. A small aluminum pressure cylinder supplies gas to a laminar flow meter, and the integrated throughput of the laminar flow meter is compared to the weight decrease of the cylinder. The two standards, which have standard uncertainties of 0.019 %, agree to within combined uncertainties with each other and with a third primary standard at NIST based on pressure measurements at constant volume. PMID:27366623

  5. Fast charging technique for high power LiFePO4 batteries: A mechanistic analysis of aging

    NASA Astrophysics Data System (ADS)

    Anseán, D.; Dubarry, M.; Devie, A.; Liaw, B. Y.; García, V. M.; Viera, J. C.; González, M.

    2016-07-01

    One of the major issues hampering the acceptance of electric vehicles (EVs) is the anxiety associated with long charging time. Hence, the ability to fast charging lithium-ion battery (LIB) systems is gaining notable interest. However, fast charging is not tolerated by all LIB chemistries because it affects battery functionality and accelerates its aging processes. Here, we investigate the long-term effects of multistage fast charging on a commercial high power LiFePO4-based cell and compare it to another cell tested under standard charging. Coupling incremental capacity (IC) and IC peak area analysis together with mechanistic model simulations ('Alawa' toolbox with harvested half-cell data), we quantify the degradation modes that cause aging of the tested cells. The results show that the proposed fast charging technique caused similar aging effects as standard charging. The degradation is caused by a linear loss of lithium inventory, coupled with a less degree of linear loss of active material on the negative electrode. This study validates fast charging as a feasible mean of operation for this particular LIB chemistry and cell architecture. It also illustrates the benefits of a mechanistic approach to understand cell degradation on commercial cells.

  6. Measurement Challenges for Carbon Nanotube Material

    NASA Technical Reports Server (NTRS)

    Sosa, Edward; Arepalli, Sivaram; Nikolaev, Pasha; Gorelik, Olga; Yowell, Leonard

    2006-01-01

    The advances in large scale applications of carbon nanotubes demand a reliable supply of raw and processed materials. It is imperative to have a consistent quality control of these nanomaterials to distinguish material inconsistency from the modifications induced by processing of nanotubes for any application. NASA Johnson Space Center realized this need five years back and started a program to standardize the characterization methods. The JSC team conducted two workshops (2003 and 2005) in collaboration with NIST focusing on purity and dispersion measurement issues of carbon nanotubes [1]. In 2004, the NASA-JSC protocol was developed by combining analytical techniques of SEM, TEM, UV-VIS-NIR absorption, Raman, and TGA [2]. This protocol is routinely used by several researchers across the world as a first step in characterizing raw and purified carbon nanotubes. A suggested practice guide consisting of detailed chapters on TGA, Raman, electron microscopy and NIR absorption is in the final stages and is undergoing revisions with input from the nanotube community [3]. The possible addition of other techniques such as XPS, and ICP to the existing protocol will be presented. Recent activities at ANSI and ISO towards implementing these protocols as nanotube characterization standards will be discussed.

  7. Pedagogical Techniques of Improvisation Instructors without Academic Credentials

    ERIC Educational Resources Information Center

    Salonen, Richard Wayne

    2010-01-01

    The importance of music improvisation can be seen in its inclusion in the National Standards for Music Education and the accreditation standards for the National Association of Schools of Music. The purpose of this study was to examine the pedagogical techniques and materials of improvisation instructors who do not hold academic credentials. The…

  8. Situational Management, Standard Setting, and Self-Reward in a Behavior Modification Weight Loss Program.

    ERIC Educational Resources Information Center

    Chapman, Stanley L.; Jeffrey, D. Balfour

    1978-01-01

    In comprehensive wieght loss program, overweight women exposed to instruction in self-standard setting and to situational management techniques lost more weight than those instructed only in situational management techniques. Findings illustrate facilitative effect of teaching individuals to set specific, objective, and realistic goals for eating…

  9. Strain Gauge Balance Calibration and Data Reduction at NASA Langley Research Center

    NASA Technical Reports Server (NTRS)

    Ferris, A. T. Judy

    1999-01-01

    This paper will cover the standard force balance calibration and data reduction techniques used at Langley Research Center. It will cover balance axes definition, balance type, calibration instrumentation, traceability of standards to NIST, calibration loading procedures, balance calibration mathematical model, calibration data reduction techniques, balance accuracy reporting, and calibration frequency.

  10. New radiotherapeutic techniques in nuclear ophthalmology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fairchild, R.G.

    Various aspects of radiotherapeutic techniques used in treating ocular tumors are discussed. Previous and current ''standard'' modalities are briefly reviewed, including beta and gamma emitters, /sup 60/Co, /sup 125/I, and charged particles. In particular, emphasis is placed upon techniques under development that use biomolecules to physiologically target radioactive or stable isotopes to ocular melanoma. These procedures include /sup 35/S-thiouracil, /sup 127/I-deoxyuridine in conjunction with irradiation with photons from /sup 145/Sm, neutron capture therapy, and various combinations of the above. Thiouracil shows particular promise because of its incorporation during melanin synthesis in growing melanoma. Radiosensitization and stimulation of Auger cascades viamore » introduction of iodine in DNA followed by irradiation with activating photons of appropriate energy (from /sup 145/Sm) has been shown to be effective in vitro. Various molecules may be used to transport boron to ocular melanoma, including thiouracil, thus allowing selective irradiation of tumor cells via /sup 10/B (n, alpha) /sup 7/Li reaction.« less

  11. Total energy expenditure in burned children using the doubly labeled water technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goran, M.I.; Peters, E.J.; Herndon, D.N.

    Total energy expenditure (TEE) was measured in 15 burned children with the doubly labeled water technique. Application of the technique in burned children required evaluation of potential errors resulting from nutritional intake altering background enrichments during studies and from the high rate of water turnover relative to CO2 production. Five studies were discarded because of these potential problems. TEE was 1.33 +/- 0.27 times predicted basal energy expenditure (BEE), and in studies where resting energy expenditure (REE) was simultaneously measured, TEE was 1.18 +/- 0.17 times REE, which in turn was 1.16 +/- 0.10 times predicted BEE. TEE was significantlymore » correlated with measured REE (r2 = 0.92) but not with predicted BEE. These studies substantiate the advantage of measuring REE to predict TEE in severely burned patients as opposed to relying on standardized equations. Therefore we recommend that optimal nutritional support will be achieved in convalescent burned children by multiplying REE by an activity factor of 1.2.« less

  12. Provably secure identity-based identification and signature schemes from code assumptions

    PubMed Central

    Zhao, Yiming

    2017-01-01

    Code-based cryptography is one of few alternatives supposed to be secure in a post-quantum world. Meanwhile, identity-based identification and signature (IBI/IBS) schemes are two of the most fundamental cryptographic primitives, so several code-based IBI/IBS schemes have been proposed. However, with increasingly profound researches on coding theory, the security reduction and efficiency of such schemes have been invalidated and challenged. In this paper, we construct provably secure IBI/IBS schemes from code assumptions against impersonation under active and concurrent attacks through a provably secure code-based signature technique proposed by Preetha, Vasant and Rangan (PVR signature), and a security enhancement Or-proof technique. We also present the parallel-PVR technique to decrease parameter values while maintaining the standard security level. Compared to other code-based IBI/IBS schemes, our schemes achieve not only preferable public parameter size, private key size, communication cost and signature length due to better parameter choices, but also provably secure. PMID:28809940

  13. Provably secure identity-based identification and signature schemes from code assumptions.

    PubMed

    Song, Bo; Zhao, Yiming

    2017-01-01

    Code-based cryptography is one of few alternatives supposed to be secure in a post-quantum world. Meanwhile, identity-based identification and signature (IBI/IBS) schemes are two of the most fundamental cryptographic primitives, so several code-based IBI/IBS schemes have been proposed. However, with increasingly profound researches on coding theory, the security reduction and efficiency of such schemes have been invalidated and challenged. In this paper, we construct provably secure IBI/IBS schemes from code assumptions against impersonation under active and concurrent attacks through a provably secure code-based signature technique proposed by Preetha, Vasant and Rangan (PVR signature), and a security enhancement Or-proof technique. We also present the parallel-PVR technique to decrease parameter values while maintaining the standard security level. Compared to other code-based IBI/IBS schemes, our schemes achieve not only preferable public parameter size, private key size, communication cost and signature length due to better parameter choices, but also provably secure.

  14. Standardizing Descemet Membrane Endothelial Keratoplasty Graft Preparation Method in the Eye Bank-Experience of 527 Descemet Membrane Endothelial Keratoplasty Tissues.

    PubMed

    Parekh, Mohit; Baruzzo, Mattia; Favaro, Elisa; Borroni, Davide; Ferrari, Stefano; Ponzin, Diego; Ruzza, Alessandro

    2017-12-01

    To share the experience and provide a standardized protocol for Descemet membrane endothelial keratoplasty (DMEK) graft preparation. A retrospective study based on 527 prestripped DMEK tissues that were prepared between 2014 and 2017. The experience of using different instruments and techniques has been described, and a standardized technique for preparing DMEK grafts has been identified. The tissues in general were prepared by superficially tapping the endothelial side with a Moria trephine (9.5 mm diameter). The plane of cleavage was identified using a cleavage hook, and the DMEK graft was deadhered from the trephined site throughout the circumference for ease of excising the graft. The DMEK graft was peeled using either one or multiple quadrant methods depending on the challenges faced during excision. The graft was finally marked with the letter "F" to identify the orientation during surgery. Data on endothelial cell loss (ECL) and challenging cases were observed, monitored, and recorded during this period. Less than 1 percent trypan blue-positive cells with tissue wastage of <6% was observed during the study period. Our standardized stripping technique has resulted in an overall ECL of 4.6%. Marking Descemet membrane showed 0.5% cell mortality. Standardizing DMEK technique using specific tools and simple techniques would help new surgeons to decide the instruments and improve their tissue preparation skills also in challenging cases such as previous cataract incisions or horseshoe-shaped tears, further reducing ECL or tissue wastage.

  15. Breast density quantification with cone-beam CT: A post-mortem study

    PubMed Central

    Johnson, Travis; Ding, Huanjun; Le, Huy Q.; Ducote, Justin L.; Molloi, Sabee

    2014-01-01

    Forty post-mortem breasts were imaged with a flat-panel based cone-beam x-ray CT system at 50 kVp. The feasibility of breast density quantification has been investigated using standard histogram thresholding and an automatic segmentation method based on the fuzzy c-means algorithm (FCM). The breasts were chemically decomposed into water, lipid, and protein immediately after image acquisition was completed. The percent fibroglandular volume (%FGV) from chemical analysis was used as the gold standard for breast density comparison. Both image-based segmentation techniques showed good precision in breast density quantification with high linear coefficients between the right and left breast of each pair. When comparing with the gold standard using %FGV from chemical analysis, Pearson’s r-values were estimated to be 0.983 and 0.968 for the FCM clustering and the histogram thresholding techniques, respectively. The standard error of the estimate (SEE) was also reduced from 3.92% to 2.45% by applying the automatic clustering technique. The results of the postmortem study suggested that breast tissue can be characterized in terms of water, lipid and protein contents with high accuracy by using chemical analysis, which offers a gold standard for breast density studies comparing different techniques. In the investigated image segmentation techniques, the FCM algorithm had high precision and accuracy in breast density quantification. In comparison to conventional histogram thresholding, it was more efficient and reduced inter-observer variation. PMID:24254317

  16. Application of manual assessment of oxygen radical absorbent capacity (ORAC) for use in high throughput assay of "total" antioxidant activity of drugs and natural products.

    PubMed

    Price, Joseph A; Sanny, Charles G; Shevlin, Dennis

    2006-01-01

    Antioxidants are of particular interest in a spectrum of diseases, and thus are an active area of drug discovery and design. It is important to make considered choices as to which assay chemistry will best serve for particular investigations. We examined the manual oxygen radical absorbent capacity (ORAC) assay for "total" antioxidant activity, including a direct comparison to an alternative technique, the AOP-490 assay, using a panel of extracts from 12 phylogenetically unrelated algae. The AOP-490 assay was done per manufacturer's protocol. The ORAC assay was done by hand, in 96-well plates, not by machine as had been previously published. Our ORAC calculations were done using an in-experiment antioxidant standard curve. Results were reported as equivalents of the antioxidant Trolox, which was used as a standard. With the AOP-490 kit (from Oxis Research) widespread activity was found, but not in all samples. When the ORAC method was used to assay aliquots of the same extracts there was significant activity detected in all samples, and the rank order of activity by the two methods was not identical. The data showed the wide occurrence of antioxidants in algae. The standard curve with the manual ORAC assay was linear in the range tested (0-100 mM Trolox) and had excellent reproducibility. The importance of the beneficial effects of antioxidants is currently an area of active interest for drug development, and thus it is of great value to have an assay that is robust and approximates "total" antioxidant activity in a high throughput format. The ORAC (oxygen radical absorbent capacity) method was adapted to microplates and an eight-channel pipette and was more effective in detecting "total" antioxidant activity than the AOP-490 assay. These results might vary with other types of samples, and would depend on the active agents measured, but do suggest the practical value of the ORAC assay for any laboratory not ready for robotics but using manual 96-well format assays, and the utility of the ORAC assay for evaluating algal, and probably other samples as well.

  17. Second Aerospace Environmental Technology Conference

    NASA Technical Reports Server (NTRS)

    Whitaker, A. F. (Editor); Clark-Ingram, M. (Editor)

    1997-01-01

    The mandated elimination of CFC'S, Halons, TCA, and other ozone depleting chemicals and specific hazardous materials has required changes and new developments in aerospace materials and processes. The aerospace industry has been involved for several years in providing product substitutions, redesigning entire production processes, and developing new materials that minimize or eliminate damage to the environment. These activities emphasize replacement cleaning solvents and their application, verification, compliant coatings including corrosion protection system and removal techniques, chemical propulsion effects on the environment, and the initiation of modifications to relevant processing and manufacturing specifications and standards.

  18. Second Aerospace Environmental Technology Conference

    NASA Technical Reports Server (NTRS)

    Whitaker, A. F.; Clark-Ingram, M.; Hessler, S. L.

    1997-01-01

    The mandated elimination of CFC's, Halons, TCA, and other ozone depleting chemicals and specific hazardous materials has required changes and new developments in aerospace materials and processes. The aerospace industry has been involved for several years in providing product substitutions, redesigning entire production processes, and developing new materials that minimize or eliminate damage to the environment. These activities emphasize replacement cleaning solvents and their application verifications, compliant coatings including corrosion protection systems, and removal techniques, chemical propulsion effects on the environment, and the initiation of modifications to relevant processing and manufacturing specifications and standards.

  19. Deep levels in H-irradiated GaAs1-xNx (x < 0.01) grown by molecular beam epitaxy

    NASA Astrophysics Data System (ADS)

    Shafi, M.; Mari, R. H.; Khatab, A.; Henini, M.; Polimeni, A.; Capizzi, M.; Hopkinson, M.

    2011-12-01

    Dilute nitride GaAs1-xNx layers have been grown by molecular beam epitaxy with nitrogen concentration ranging from 0.2% to 0.8%. These samples have been studied before and after hydrogen irradiation by using standard deep level transient spectroscopy (DLTS) and high resolution Laplace DLTS techniques. The activation energy, capture cross section and density of the electron traps have been estimated and compared with results obtained in N-free as-grown and H-irradiated bulk GaAs.

  20. Survey of Software Assurance Techniques for Highly Reliable Systems

    NASA Technical Reports Server (NTRS)

    Nelson, Stacy

    2004-01-01

    This document provides a survey of software assurance techniques for highly reliable systems including a discussion of relevant safety standards for various industries in the United States and Europe, as well as examples of methods used during software development projects. It contains one section for each industry surveyed: Aerospace, Defense, Nuclear Power, Medical Devices and Transportation. Each section provides an overview of applicable standards and examples of a mission or software development project, software assurance techniques used and reliability achieved.

  1. Accelerated Slice Encoding for Metal Artifact Correction

    PubMed Central

    Hargreaves, Brian A.; Chen, Weitian; Lu, Wenmiao; Alley, Marcus T.; Gold, Garry E.; Brau, Anja C. S.; Pauly, John M.; Pauly, Kim Butts

    2010-01-01

    Purpose To demonstrate accelerated imaging with artifact reduction near metallic implants and different contrast mechanisms. Materials and Methods Slice-encoding for metal artifact correction (SEMAC) is a modified spin echo sequence that uses view-angle tilting and slice-direction phase encoding to correct both in-plane and through-plane artifacts. Standard spin echo trains and short-TI inversion recovery (STIR) allow efficient PD-weighted imaging with optional fat suppression. A completely linear reconstruction allows incorporation of parallel imaging and partial Fourier imaging. The SNR effects of all reconstructions were quantified in one subject. 10 subjects with different metallic implants were scanned using SEMAC protocols, all with scan times below 11 minutes, as well as with standard spin echo methods. Results The SNR using standard acceleration techniques is unaffected by the linear SEMAC reconstruction. In all cases with implants, accelerated SEMAC significantly reduced artifacts compared with standard imaging techniques, with no additional artifacts from acceleration techniques. The use of different contrast mechanisms allowed differentiation of fluid from other structures in several subjects. Conclusion SEMAC imaging can be combined with standard echo-train imaging, parallel imaging, partial-Fourier imaging and inversion recovery techniques to offer flexible image contrast with a dramatic reduction of metal-induced artifacts in scan times under 11 minutes. PMID:20373445

  2. Accelerated slice encoding for metal artifact correction.

    PubMed

    Hargreaves, Brian A; Chen, Weitian; Lu, Wenmiao; Alley, Marcus T; Gold, Garry E; Brau, Anja C S; Pauly, John M; Pauly, Kim Butts

    2010-04-01

    To demonstrate accelerated imaging with both artifact reduction and different contrast mechanisms near metallic implants. Slice-encoding for metal artifact correction (SEMAC) is a modified spin echo sequence that uses view-angle tilting and slice-direction phase encoding to correct both in-plane and through-plane artifacts. Standard spin echo trains and short-TI inversion recovery (STIR) allow efficient PD-weighted imaging with optional fat suppression. A completely linear reconstruction allows incorporation of parallel imaging and partial Fourier imaging. The signal-to-noise ratio (SNR) effects of all reconstructions were quantified in one subject. Ten subjects with different metallic implants were scanned using SEMAC protocols, all with scan times below 11 minutes, as well as with standard spin echo methods. The SNR using standard acceleration techniques is unaffected by the linear SEMAC reconstruction. In all cases with implants, accelerated SEMAC significantly reduced artifacts compared with standard imaging techniques, with no additional artifacts from acceleration techniques. The use of different contrast mechanisms allowed differentiation of fluid from other structures in several subjects. SEMAC imaging can be combined with standard echo-train imaging, parallel imaging, partial-Fourier imaging, and inversion recovery techniques to offer flexible image contrast with a dramatic reduction of metal-induced artifacts in scan times under 11 minutes. (c) 2010 Wiley-Liss, Inc.

  3. Use of fractography and sectioning techniques to study fracture mechanisms

    NASA Technical Reports Server (NTRS)

    Van Stone, R. H.; Cox, T. B.

    1976-01-01

    Recent investigations of the effect of microstructure on the fracture mechanisms and fracture toughness of steels, aluminum alloys, and titanium alloys have used standard fractographic techniques and a sectioning technique on specimens plastically deformed to various strains up to fracture. The specimens are prepared metallographically for observation in both optical and electron beam instruments. This permits observations to be made about the fracture mechanism as it occurs in thick sections and helps remove speculation from the interpretation of fractographic features. This technique may be used in conjunction with other standard techniques such as extraction replicas and microprobe analyses. Care must be taken to make sure that the microstructural features which are observed to play a role in the fracture process using the sectioning technique can be identified with fractography.

  4. Revised techniques for estimating peak discharges from channel width in Montana

    USGS Publications Warehouse

    Parrett, Charles; Hull, J.A.; Omang, R.J.

    1987-01-01

    This study was conducted to develop new estimating equations based on channel width and the updated flood frequency curves of previous investigations. Simple regression equations for estimating peak discharges with recurrence intervals of 2, 5, 10 , 25, 50, and 100 years were developed for seven regions in Montana. The standard errors of estimates for the equations that use active channel width as the independent variables ranged from 30% to 87%. The standard errors of estimate for the equations that use bankfull width as the independent variable ranged from 34% to 92%. The smallest standard errors generally occurred in the prediction equations for the 2-yr flood, 5-yr flood, and 10-yr flood, and the largest standard errors occurred in the prediction equations for the 100-yr flood. The equations that use active channel width and the equations that use bankfull width were determined to be about equally reliable in five regions. In the West Region, the equations that use bankfull width were slightly more reliable than those based on active channel width, whereas in the East-Central Region the equations that use active channel width were slightly more reliable than those based on bankfull width. Compared with similar equations previously developed, the standard errors of estimate for the new equations are substantially smaller in three regions and substantially larger in two regions. Limitations on the use of the estimating equations include: (1) The equations are based on stable conditions of channel geometry and prevailing water and sediment discharge; (2) The measurement of channel width requires a site visit, preferably by a person with experience in the method, and involves appreciable measurement errors; (3) Reliability of results from the equations for channel widths beyond the range of definition is unknown. In spite of the limitations, the estimating equations derived in this study are considered to be as reliable as estimating equations based on basin and climatic variables. Because the two types of estimating equations are independent, results from each can be weighted inversely proportional to their variances, and averaged. The weighted average estimate has a variance less than either individual estimate. (Author 's abstract)

  5. Development of improved electroforming technique. [for fabricating regeneratively cooled thrust chambers

    NASA Technical Reports Server (NTRS)

    Mccandles, L. C.; Davies, L. G.

    1973-01-01

    Techniques were studied to reinforce or strengthen electroformed nickel to allow a fuller utilization of electroforming as a reliable and low cost fabrication technique for regenerately cooled thrust chambers. Techniques for wire wrapping while electrodepositing were developed that can result in a structurally strong wall with less weight than a conventional electroformed wall. Also a technique of codepositing submicron sized THO2 particles with the nickel to form a dispersion strengthened structure was evaluated. The standard nickel cylinders exhibited an average hoop strength of 80,000 psi with a yield strength of 65,000 psi and a modulus of 25.6 x 10 to the 6th power psi. The as produced dispersion strengthened nickel showed a hoop strength of 97,000 psi with a yield strength of 67,000 psi. This is an increase of 17,000 psi or 21% over the standard nickel hoop strength. The wire wrapping cylinders showed an increased strength over the standard nickel test samples of 26,000 to 66,800 psi which is in the range of 26 to 104% increase in strength over the base standard nickel. These latter test results are indicative of a volume percent wire reinforcement from 15 to 31. The measured hoop strengths agree with calculated composite strengths based upon rule of mixtures.

  6. Structural symmetry breaking of silicon containing polymers and their relation with electrical conductivity and Raman active vibrations

    NASA Astrophysics Data System (ADS)

    Cabrera, Alejandro; González, Carmen; Tagle, Luis; Terraza, Claudio; Volkmann, Ulrich; Barriga, Andrés; Ramos, Esteban; Pavez, Maximiliano

    2011-03-01

    The incorporation of silicon into the polymeric main chain or side groups can provide an enhancement in chemical, physical and mechanical properties. We report an efficient method for the synthesis of polymers containing silicon in the main chain, from the polycondensation reactions of four optically active carboxylic diacid. The solubility of the polymers, the molecular weight, the glass transition and the thermal stability were studied by standard techniques. Raman spectroscopy was used to probe the conformation of stretching modes as function of the temperature. The conductivity measurements indicated that the alignment of the molecules is a crucial parameter for electrical performance. When the polymers were exposed to iodine, charge transfer increased their mobility and decreased their optical band gaps. These novel properties highlight the possibility to generate alternative active opto-electronics polymers.

  7. Synthesis, in vitro β-glucuronidase inhibitory potential and molecular docking studies of quinolines.

    PubMed

    Bano, Bilquees; Arshia; Khan, Khalid Mohammed; Kanwal; Fatima, Bibi; Taha, Muhammad; Ismail, Nor Hadiani; Wadood, Abdul; Ghufran, Mehreen; Perveen, Shahnaz

    2017-10-20

    In this study synthesis and β-glucuronidase inhibitory potential of 3/5/8 sulfonamide and 8-sulfonate derivatives of quinoline (1-40) are discussed. Studies reveal that all the synthetic compounds were found to have good inhibitory activity against β-glucuronidase. Nonetheless, compounds 1, 2, 5, 13, and 22-24 having IC 50 values in the range of 1.60-8.40 μM showed superior activity than the standard saccharic acid 1,4-lactone (IC 50  = 48.4 ± 1.25 μM). Moreover, molecular docking studies of selected compounds were also performed to see interactions between active compounds and binding sites. Structures of all the synthetic compounds were confirmed through 1 H NMR, EI-MS and HREI-MS spectroscopic techniques. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  8. Fluoroscopic removal of retrievable self-expandable metal stents in patients with malignant oesophageal strictures: Experience with a non-endoscopic removal system.

    PubMed

    Kim, Pyeong Hwa; Song, Ho-Young; Park, Jung-Hoon; Zhou, Wei-Zhong; Na, Han Kyu; Cho, Young Chul; Jun, Eun Jung; Kim, Jun Ki; Kim, Guk Bae

    2017-03-01

    To evaluate clinical outcomes of fluoroscopic removal of retrievable self-expandable metal stents (SEMSs) for malignant oesophageal strictures, to compare clinical outcomes of three different removal techniques, and to identify predictive factors of successful removal by the standard technique (primary technical success). A total of 137 stents were removed from 128 patients with malignant oesophageal strictures. Primary overall technical success and removal-related complications were evaluated. Logistic regression models were constructed to identify predictive factors of primary technical success. Primary technical success rate was 78.8 % (108/137). Complications occurred in six (4.4 %) cases. Stent location in the upper oesophagus (P=0.004), stricture length over 8 cm (P=0.030), and proximal granulation tissue (P<0.001) were negative predictive factors of primary technical success. If granulation tissue was present at the proximal end, eversion technique was more frequently required (P=0.002). Fluoroscopic removal of retrievable SEMSs for malignant oesophageal strictures using three different removal techniques appeared to be safe and easy. The standard technique is safe and effective in the majority of patients. The presence of proximal granulation tissue, stent location in the upper oesophagus, and stricture length over 8 cm were negative predictive factors for primary technical success by standard extraction and may require a modified removal technique. • Fluoroscopic retrievable SEMS removal is safe and effective. • Standard removal technique by traction is effective in the majority of patients. • Three negative predictive factors of primary technical success were identified. • Caution should be exercised during the removal in those situations. • Eversion technique is effective in cases of proximal granulation tissue.

  9. Prevention, treatment, and rehabilitation of anterior cruciate ligament injuries in children

    PubMed Central

    Lang, Pamela J; Sugimoto, Dai; Micheli, Lyle J

    2017-01-01

    As more children and adolescents participate in competitive organized sports, there has been an increase in the reported incidence of anterior cruciate ligament (ACL) injuries in these age groups. ACL injuries in skeletally immature athletes present a challenge, as reconstruction must preserve the physis of the distal femur and of the proximal tibia to avoid growth disturbances. Historically, a skeletally immature athlete with an ACL injury was treated with a brace and activity modification until skeletal maturity, with ACL reconstruction being performed at that time in the “non-copers” who experienced instability. More recently, evidence has shown that delayed reconstruction may lead to increased damage to the meniscus and articular cartilage. As a result, early reconstruction is favored to protect the meniscus and allow continued physical activity. While adolescents at or those near skeletal maturity may be treated with standard reconstruction techniques, they may result in growth disturbances in younger athletes with significant growth remaining. In response to the growing need for ACL reconstruction techniques in skeletally immature individuals, physeal-sparing and physeal-respecting reconstruction techniques have been developed. In addition to the advancements in surgical technique, ACL injury prevention has also gained attention. This growing interest in ACL prevention is in part related to the high risk of ACL re-tear, either of the ACL graft or of the contralateral ACL, in children and adolescents. Recent reports indicate that well-designed neuromuscular training programs may reduce the risk of primary and subsequent ACL injuries. PMID:28652828

  10. Estimation of the caesium-137 source term from the Fukushima Daiichi nuclear power plant using a consistent joint assimilation of air concentration and deposition observations

    NASA Astrophysics Data System (ADS)

    Winiarek, Victor; Bocquet, Marc; Duhanyan, Nora; Roustan, Yelva; Saunier, Olivier; Mathieu, Anne

    2014-01-01

    Inverse modelling techniques can be used to estimate the amount of radionuclides and the temporal profile of the source term released in the atmosphere during the accident of the Fukushima Daiichi nuclear power plant in March 2011. In Winiarek et al. (2012b), the lower bounds of the caesium-137 and iodine-131 source terms were estimated with such techniques, using activity concentration measurements. The importance of an objective assessment of prior errors (the observation errors and the background errors) was emphasised for a reliable inversion. In such critical context where the meteorological conditions can make the source term partly unobservable and where only a few observations are available, such prior estimation techniques are mandatory, the retrieved source term being very sensitive to this estimation. We propose to extend the use of these techniques to the estimation of prior errors when assimilating observations from several data sets. The aim is to compute an estimate of the caesium-137 source term jointly using all available data about this radionuclide, such as activity concentrations in the air, but also daily fallout measurements and total cumulated fallout measurements. It is crucial to properly and simultaneously estimate the background errors and the prior errors relative to each data set. A proper estimation of prior errors is also a necessary condition to reliably estimate the a posteriori uncertainty of the estimated source term. Using such techniques, we retrieve a total released quantity of caesium-137 in the interval 11.6-19.3 PBq with an estimated standard deviation range of 15-20% depending on the method and the data sets. The “blind” time intervals of the source term have also been strongly mitigated compared to the first estimations with only activity concentration data.

  11. In vivo facet joint loading of the canine lumbar spine.

    PubMed

    Buttermann, G R; Schendel, M J; Kahmann, R D; Lewis, J L; Bradford, D S

    1992-01-01

    This study describes a technique to measure in vivo loads and the resultant load-contact locations in the facet joint of the canine lumbar spine. The technique is a modification of a previously described in vitro method that used calibrated surface strains of the lateral aspect of the right L3 cranial articular process. In the present study, strains were measured during various in vivo static and dynamic activities 3 days after strain gage implantation. The in vivo recording technique and its errors, which depend on the location of the applied facet loads, is described. The results of applying the technique to five dogs gave the following results. Relative resultant contact load locations on the facet tended to be in the central and caudal portion of the facet in extension activities, central and cranial in standing, and cranial and ventral in flexion or right-turning activities. Right-turning contact locations were ventral and cranial to left-turning locations. Resultant load locations at peak loading during walking were in the central region of the facet, whereas resultant load locations at minimum loading during walking were relatively craniad. This resultant load-contact location during a walk gait cycle typically migrated in an arc with a displacement of 4 mm from minimum to maximum loading. Static tests resulted in a range of facet loads of 0 N in flexion and lying to 185 N for two-legged standing erect, and stand resulted in facet loads of 26 +/- 15 N (mean +/- standard deviation [SD]). Dynamic tests resulted in peak facet loads ranging from 55 N while walking erect to 170 N for climbing up stairs. Maximum walk facet loads were 107 +/- 27 N. The technique is applicable to in vivo studies of a canine facet joint osteoarthritis model and may be useful for establishing an understanding of the biomechanics of low-back pain.

  12. Comparison of Selective Culturing and Biochemical Techniques for Measuring Biological Activity in Geothermal Process Fluids

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pryfogle, Peter Albert

    2000-09-01

    For the past three years, scientists at the Idaho National Engineering and Environmental Laboratory have been conducting studies aimed at determining the presence and influence of bacteria found in geothermal plant cooling water systems. In particular, the efforts have been directed at understanding the conditions that lead to the growth and accumulation of biomass within these systems, reducing the operational and thermal efficiency. Initially, the methods selected were based upon the current practices used by the industry and included the collection of water quality parameters, the measurement of soluble carbon, and the use of selective medial for the determination ofmore » the number density of various types of organisms. This data has been collected on a seasonal basis at six different facilities located at the Geysers’ in Northern California. While this data is valuable in establishing biological growth trends in the facilities and providing an initial determination of upset or off-normal conditions, more detailed information about the biological activity is needed to determine what is triggering or sustaining the growth in these facilities in order to develop improved monitoring and treatment techniques. In recent years, new biochemical approaches, based upon the analyses of phospholipid fatty acids and DNA recovered from environmental samples, have been developed and commercialized. These techniques, in addition to allowing the determination of the quantity of biomass, also provide information on the community composition and the nutritional status of the organisms. During the past year, samples collected from the condenser effluents of four of the plants from The Geysers’ were analyzed using these methods and compared with the results obtained from selective culturing techniques. The purpose of this effort was to evaluate the cost-benefit of implementing these techniques for tracking microbial activity in the plant study, in place of the selective culturing analyses that are currently the industry standard.« less

  13. Neurodevelopmental outcome at 2 years in twin-twin transfusion syndrome survivors randomized for the Solomon trial.

    PubMed

    van Klink, Jeanine M M; Slaghekke, Femke; Balestriero, Marina A; Scelsa, Barbara; Introvini, Paola; Rustico, Mariangela; Faiola, Stefano; Rijken, Monique; Koopman, Hendrik M; Middeldorp, Johanna M; Oepkes, Dick; Lopriore, Enrico

    2016-01-01

    The preferred treatment for twin-twin transfusion syndrome is fetoscopic laser coagulation of inter-twin vascular anastomoses on the monochorionic placenta. Severe postoperative complications can occur when inter-twin vascular anastomoses remain patent including twin-anemia polycythemia sequence or recurrent twin-twin transfusion syndrome. To minimize the occurrence of residual anastomoses, a modified laser surgery technique, the Solomon technique, was developed in which the entire vascular equator is coagulated. In the Solomon randomized controlled trial (NTR1245), the Solomon technique was associated with a significant reduction in twin-anemia polycythemia sequence and recurrence of twin-twin transfusion syndrome when compared with the standard laser surgery technique. Although a significant improvement in perinatal outcome was shown after the Solomon technique, the clinical importance should also be ascertained with long-term follow-up evaluation of the surviving children. The purpose of this study was to compare the long-term neurodevelopmental outcome in surviving children with twin-twin transfusion syndrome who were included in the Solomon randomized trial and treated with either the Solomon technique or standard laser surgery technique. Routine standardized follow-up evaluation in survivors, at least 2 years after the estimated date of delivery, was performed at 2 of the 5 centers that participated in the Solomon trial: Buzzi Hospital Milan (Italy) and Leiden University Medical Center (The Netherlands). The primary outcome of this follow-up study was survival without long-term neurodevelopmental impairment at age 2 years. Neurodevelopmental impairment was defined as cerebral palsy, cognitive and/or motor development score of <85, bilateral blindness, or deafness. Cognitive and motor development was evaluated with the use of Bayley-III. All analyses per fetus, neonate, or child were conducted with the generalized estimated equation module to account for the effect that observations between co-twins are not independent. The primary outcome (survival without neurodevelopmental impairment) was detected in 95 of 141 cases (67%) in the Solomon group and in 99 of 146 cases (68%) in the standard group (P = .92). Neurodevelopmental impairment in long-term survivors who were included for follow-up evaluation was detected in 12 of 107 cases (11%) in the Solomon and in 10 of 109 cases (9%) in the standard group (P = .61). Neurodevelopmental impairment was due to cerebral palsy in 1 case (1%; spastic unilateral) in the Solomon group and in 2 cases (2%; spastic unilateral and spastic bilateral) in the standard group (P = .58). Cognitive development <85 cases was detected in 2 of 105 children (2%) in the Solomon group and in 6 of 106 children (6%) in the standard group (P = .23). Motor development <85 occurred in 8 of 103 children (8%) in the Solomon group and 3 of 104 children (3%) in the standard group (P = .23). We found no difference in survival without neurodevelopmental impairment between the Solomon and standard laser techniques. In view of the reduction of short-term complications and the absence of increased adverse long-term effects, these data support the use of the Solomon technique in the treatment of twin-twin transfusion syndrome. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Comparison of Quadrapolar™ radiofrequency lesions produced by standard versus modified technique: an experimental model.

    PubMed

    Safakish, Ramin

    2017-01-01

    Lower back pain (LBP) is a global public health issue and is associated with substantial financial costs and loss of quality of life. Over the years, different literature has provided different statistics regarding the causes of the back pain. The following statistic is the closest estimation regarding our patient population. The sacroiliac (SI) joint pain is responsible for LBP in 18%-30% of individuals with LBP. Quadrapolar™ radiofrequency ablation, which involves ablation of the nerves of the SI joint using heat, is a commonly used treatment for SI joint pain. However, the standard Quadrapolar radiofrequency procedure is not always effective at ablating all the sensory nerves that cause the pain in the SI joint. One of the major limitations of the standard Quadrapolar radiofrequency procedure is that it produces small lesions of ~4 mm in diameter. Smaller lesions increase the likelihood of failure to ablate all nociceptive input. In this study, we compare the standard Quadrapolar radiofrequency ablation technique to a modified Quadrapolar ablation technique that has produced improved patient outcomes in our clinic. The methodology of the two techniques are compared. In addition, we compare results from an experimental model comparing the lesion sizes produced by the two techniques. Taken together, the findings from this study suggest that the modified Quadrapolar technique provides longer lasting relief for the back pain that is caused by SI joint dysfunction. A randomized controlled clinical trial is the next step required to quantify the difference in symptom relief and quality of life produced by the two techniques.

  15. Immunochemical Parameters of Some Commercial Conjugates for the Fluorescent Treponemal Antibody-Absorption Test

    PubMed Central

    Hunter, E. F.; Smith, J. F.; Lewis, J. S.; McGrew, B. E.; Schmale, J. D.

    1972-01-01

    Fluorescein-labeled anti-human globulins were examined to determine the need for standardization of conjugates used in the fluorescent treponemal antibody-absorption (FTA-ABS) test. Twenty-one of 33 conjugates submitted by commercial manufacturers to the Reagents Control Activity, Venereal Disease Research Laboratory, for evaluation in the FTA-ABS test were available for study. Conjugates, after evaluation in FTA-ABS performance tests, were examined by immunoelectrophoresis, by titration against immunoglobulins G and M (IgG, IgM) with FTA-ABS techniques, and by the biuret protein and fluorescein diacetate methods for determining fluorescein to protein (F/P) ratios. The conjugates were predominately anti-IgG globulin with anti-light-chain activity. Differences were noted in the ability of some conjugates to detect IgM antibody. The F/P ratios of those conjugates that could be determined varied from 2.6 to 17.8 μg of fluorescein per mg of protein. The need to identify and standardize both the immunologic capabilities and the optimum F/P ratio for FTA-ABS test conjugates is presented. PMID:4564403

  16. Patellar fixation protected with a load-sharing cable: a mechanical and clinical study.

    PubMed

    Perry, C R; McCarthy, J A; Kain, C C; Pearson, R L

    1988-01-01

    The stability of patellar fracture fixation protected with a load-sharing cable was studied in cadavers. A transverse patellar osteotomy was produced and stabilized with standard patellar fixation with or without a figure-of-eight cable that extends from the proximal pole of the patella to the tibial tubercle. Standard fixation techniques (interfragmentary cancellous screws or modified tension-band wiring) alone failed after significantly fewer cycles of flexion and extension than did the same fixation when supplemented with a load-sharing cable. In the clinical evaluation of the load-sharing cable, 14 consecutive patients with displaced patellar fractures were treated. No immobilization was used and the patients were started on passive and active range of motion and weight-bearing ambulation in the early postoperative period. Thirteen fractures healed uneventfully. The increased stability of patellar fracture fixation protected with a load-sharing cable offers three advantages: (a) adjunctive casting is unnecessary, (b) comminuted fractures can be "pieced" together anatomically with less concern for loss of fixation, and (c) early postoperative passive and active range of motion can be achieved.

  17. U.S. Department of Energy Nevada Operations Office Environmental Monitoring Program summary data report, second calendar quarter 1996

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Black, S.C.; Townsend, Y.E.

    1997-02-01

    The Nevada Test Site (NTS), located in southern Nevada, has been the primary location for testing of nuclear explosives in the continental US. Testing began in 1951 and continued until the moratorium in 1992. Waste storage and disposal facilities for defense radioactive and mixed waste are located in Areas 3 and 5. At the Area 5 Radioactive Waste Management Site (RWMS-5), low-level wastes (LLW) from US Department of Energy (DOE) affiliated onsite and offsite generators are disposed of using standard shallow land disposal techniques. Transuranic wastes are retrievably stored at the RWMS-5 in containers on a surface pad, pending shipmentmore » to the Waste Isolation Pilot Plant facility in New Mexico. Nonradioactive hazardous wastes are accumulated at a special site before shipment to a licensed offsite disposal facility. Non-standard packages of LLW are buried in subsidence craters in the Area 3 RWMS. This report describes these activities on and around the NTS and includes a listing of the results obtained from environmental surveillance activities during the second calendar quarter of 1996.« less

  18. Reaction rates of the 113In(γ,n)112mIn and 115In(γ,n)114mIn

    NASA Astrophysics Data System (ADS)

    Skakun, Ye; Semisalov, I.; Kasilov, V.; Popov, V.; Kochetov, S.; Maslyuk, V.; Mazur, V.; Parlag, O.; Gajnish, I.

    2016-01-01

    The integral yields of the 113In(γ,n)112mIn (Jπ=9/2+→Jπ=4+) and 115In(γ,n)114mIn (Jπ=9/2+→Jπ=5+) photonuclear reactions were measured in the bremsstrahlung end-point energy range from the respective thresholds up to 14 MeV by a conventional activation/decay technique using the 197Au(γ,n)196Au reaction cross sections as the standard for the absolute photon intensity determination. The metallic indium samples of the natural and enriched compositions were irradiated by the bremsstrahlung beams from thin tantalum converters of the electron linear accelerator of NSC KIPT (Kharkiv) and the microtron of IEP (Ughhorod). The integral reaction yields were determined from the activities of the nuclei-products measured by the high resolution γ-ray spectrometry technique with Ge(Li)- and HPGe-detectors. The reaction rates for the Planck spectrum of a thermal photon bath were derived for the ground state target nuclei and compared to the predictions of the statistical model of nuclear reactions.

  19. Effect of carbonization temperature on the physical and electrochemical properties of supercapacitor electrode from fibers of oil palm empty fruit bunches

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ishak, M. M.; Deraman, M., E-mail: madra@ukm.my; Talib, I. A.

    Self-adhesive carbon grains (SACG) was prepared from fibers of oil palm empty fruit bunches. The SACG green monoliths were carbonized in N{sub 2} environment at 400, 500, 600 and 700°C to produce carbon monoliths labeled as CM1, CM2, CM3 and CM4 respectively. The CMs were activated in CO{sub 2} surrounding at 800°C for 1 hour to produce activated carbon monolith electrodes (ACM1, ACM2, ACM3 and ACM4). The physical properties of the CMs and ACMs were investigated using X-ray diffraction, field emission scanning electron microscopy (FESEM) and N{sub 2} adsorption-desorption isotherm techniques. ACMs were used as electrode to fabricate symmetry supercapacitormore » cells and the cells’ performances were investigated using electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and galvanostatic charge-discharge (GCD) standard techniques. In this paper we report the physical and electrochemical properties of the ACM electrodes by analyzing the influence of the carbonization temperature on these properties.« less

  20. An improved technique for the 2H/1H analysis of urines from diabetic volunteers

    USGS Publications Warehouse

    Coplen, T.B.; Harper, I.T.

    1994-01-01

    The H2-H2O ambient-temperature equilibration technique for the determination of 2H/1H ratios in urinary waters from diabetic subjects provides improved accuracy over the conventional Zn reduction technique. The standard deviation, ~ 1-2???, is at least a factor of three better than that of the Zn reduction technique on urinary waters from diabetic volunteers. Experiments with pure water and solutions containing glucose, urea and albumen indicate that there is no measurable bias in the hydrogen equilibration technique.The H2-H2O ambient-temperature equilibration technique for the determination of 2H/1H ratios in urinary waters from diabetic subjects provides improved accuracy over the conventional Zn reduction technique. The standard deviation, approximately 1-2%, is at least a factor of three better than that of the Zn reduction technique on urinary waters from diabetic volunteers. Experiments with pure water and solutions containing glucose, urea and albumen indicate that there is no measurable bias in the hydrogen equilibration technique.

  1. Coliform species recovered from untreated surface water and drinking water by the membrane filter, standard, and modified most-probable-number techniques.

    PubMed Central

    Evans, T M; LeChevallier, M W; Waarvick, C E; Seidler, R J

    1981-01-01

    The species of total coliform bacteria isolated from drinking water and untreated surface water by the membrane filter (MF), the standard most-probable-number (S-MPN), and modified most-probable-number (M-MPN) techniques were compared. Each coliform detection technique selected for a different profile of coliform species from both types of water samples. The MF technique indicated that Citrobacter freundii was the most common coliform species in water samples. However, the fermentation tube techniques displayed selectivity towards the isolation of Escherichia coli and Klebsiella. The M-MPN technique selected for more C. freundii and Enterobacter spp. from untreated surface water samples and for more Enterobacter and Klebsiella spp. from drinking water samples than did the S-MPN technique. The lack of agreement between the number of coliforms detected in a water sample by the S-MPN, M-MPN, and MF techniques was a result of the selection for different coliform species by the various techniques. PMID:7013706

  2. Role of slack variables in quasi-Newton methods for constrained optimization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tapia, R.A.

    In constrained optimization the technique of converting an inequality constraint into an equality constraint by the addition of a squared slack variable is well known but rarely used. In choosing an active constraint philosophy over the slack variable approach, researchers quickly justify their choice with the standard criticisms: the slack variable approach increases the dimension of the problem, is numerically unstable, and gives rise to singular systems. It is shown that these criticisms of the slack variable approach need not apply and the two seemingly distinct approaches are actually very closely related. In fact, the squared slack variable formulation canmore » be used to develop a superior and more comprehensive active constraint philosophy.« less

  3. Software engineering for ESO's VLT project

    NASA Astrophysics Data System (ADS)

    Filippi, G.

    1994-12-01

    This paper reports on the experience at the European Southern Observatory on the application of software engineering techniques to a 200 man-year control software project for the Very Large Telescope (VLT). This shall provide astronomers, before the end of the century, with one of the most powerful telescopes in the world. From the definition of the general model, described in the software management plan, specific activities have been and will be defined: standards for documents and for code development, design approach using a CASE tool, the process of reviewing both documentation and code, quality assurance, test strategy, etc. The initial choices, the current implementation and the future planned activities are presented and, where feedback is already available, pros and cons are discussed.

  4. THE COMPARISON OF SEVERAL STANDARD MATERIALS AND TECHNIQUES FOR THE WARREN-AVERBACH DETERMINATION OF MICRO-STRUCTURE CHARACTERISTICS OF CALCIUM HYDROXIDE SORBENT MATERIALS

    EPA Science Inventory

    The paper gives results of a comparison of several standard materials and techniques for the Warren-Averbach determination of microstructure characteristics of calcium hydroxide--Ca(OH)2--sorbent materials. The comparison is part of an investigation of the injection of dry Ca(OH)...

  5. A Novel Instructional Approach to the Design of Standard Controllers: Using Inversion Formulae

    ERIC Educational Resources Information Center

    Ntogramatzidis, Lorenzo; Zanasi, Roberto; Cuoghi, Stefania

    2014-01-01

    This paper describes a range of design techniques for standard compensators (Lead-Lag networks and PID controllers) that have been applied to the teaching of many undergraduate control courses throughout Italy over the last twenty years, but that have received little attention elsewhere. These techniques hinge upon a set of simple formulas--herein…

  6. A Procedure for Estimating a Criterion-Referenced Standard to Identify Educationally Deprived Children for Title I Services. Final Report.

    ERIC Educational Resources Information Center

    Ziomek, Robert L.; Wright, Benjamin D.

    Techniques such as the norm-referenced and average score techniques, commonly used in the identification of educationally disadvantaged students, are critiqued. This study applied latent trait theory, specifically the Rasch Model, along with teacher judgments relative to the mastery of instructional/test decisions, to derive a standard setting…

  7. Supraclavicular skin temperature and BAT activity in lean healthy adults.

    PubMed

    van der Lans, Anouk A J J; Vosselman, Maarten J; Hanssen, Mark J W; Brans, Boudewijn; van Marken Lichtenbelt, Wouter D

    2016-01-01

    The 'gold standard' for measuring brown adipose tissue (BAT) in humans is [(18)F]FDG-PET/CT-imaging. With this technique subjects are exposed to ionizing radiation and are therefore limited in the number of scans that can be performed. We investigated the relation between supraclavicular skin temperatures and BAT activity values using a strictly temperature-controlled air-cooling protocol. Data of 36 male subjects was analyzed. BAT activity was evaluated by [(18)F]FDG-PET/CT-imaging and skin temperature was measured by means of wireless temperature sensors. Supraclavicular skin temperature dropped less compared to skin temperatures at other sites (all P values <0.01). A significant positive correlation was found between the change in supraclavicular skin temperature with BAT activity (R (2) 0.23), and the change in supraclavicular skin temperature and non-shivering thermogenesis (R (2) 0.18, both P values <0.01). The correlations indicate that supraclavicular skin temperature (changes) can potentially be used as a qualitative measure of BAT activity and BAT thermogenesis.

  8. Cognitive chrono-ethnography lite.

    PubMed

    Nakajima, Masato; Yamada, Kosuke C; Kitajima, Muneo

    2012-01-01

    Conducting field research facilitates understanding human daily activities. Cognitive Chrono-Ethnography (CCE) is a study methodology used to understand how people select actions in daily life by conducting ethnographical field research. CCE consists of measuring monitors' daily activities in a specified field and in-depth interviews using the recorded videos afterward. However, privacy issues may arise when conducting standard CCE with video recordings in a daily field. To resolve these issues, we developed a new study methodology, CCE Lite. To replace video recordings, we created pseudo-first-personview (PFPV) movies using a computer-graphic technique. The PFPV movies were used to remind the monitors of their activities. These movies replicated monitors' activities (e.g., locomotion and change in physical direction), with no human images and voices. We applied CCE Lite in a case study that involved female employees of hotels at a spa resort. In-depth interviews while showing the PFPV movies determined service schema of the employees (i.e., hospitality). Results indicated that using PFPV movies helped the employees to remember and reconstruct the situation of recorded activities.

  9. Intracortical Microstimulation (ICMS) Activates Motor Cortex Layer 5 Pyramidal Neurons Mainly Transsynaptically.

    PubMed

    Hussin, Ahmed T; Boychuk, Jeffery A; Brown, Andrew R; Pittman, Quentin J; Teskey, G Campbell

    2015-01-01

    Intracortical microstimulation (ICMS) is a technique used for a number of purposes including the derivation of cortical movement representations (motor maps). Its application can activate the output layer 5 of motor cortex and can result in the elicitation of body movements depending upon the stimulus parameters used. The extent to which pyramidal tract projection neurons of the motor cortex are activated transsynaptically or directly by ICMS remains an open question. Given this uncertainty in the mode of activation, we used a preparation that combined patch clamp whole-cell recordings from single layer 5 pyramidal neurons and extracellular ICMS in slices of motor cortex as well as a standard in vivo mapping technique to ask how ICMS activated motor cortex pyramidal neurons. We measured changes in synaptic spike threshold and spiking rate to ICMS in vitro and movement threshold in vivo in the presence or absence of specific pharmacological blockers of glutamatergic (AMPA, NMDA and Kainate) receptors and GABAA receptors. With major excitatory and inhibitory synaptic transmission blocked (with DNQX, APV and bicuculline methiodide), we observed a significant increase in the ICMS current intensity required to elicit a movement in vivo as well as to the first spike and an 85% reduction in spiking responses in vitro. Subsets of neurons were still responsive after the synaptic block, especially at higher current intensities, suggesting a modest direct activation. Taken together our data indicate a mainly synaptic mode of activation to ICMS in layer 5 of rat motor cortex. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Standardized limbal epithelial stem cell graft generation and transplantation.

    PubMed

    Zakaria, Nadia; Koppen, Carina; Van Tendeloo, Viggo; Berneman, Zwi; Hopkinson, Andrew; Tassignon, Marie-José

    2010-10-01

    To describe a standardized, xenogenic-free protocol for the manufacture of limbal epithelial stem cell grafts and a "no touch" surgical technique for its standardized transplantation. Antwerp University Hospital, Antwerp, Belgium. The limbo-amnion composite graft is generated by cultivating limbal epithelial stem cells on a standardized (thermolysin treated and spongy layer removed) amniotic membrane, stretched within an interlockable amnion ring. The cells are cultured in CnT-20 medium with the addition of 1% human AB serum for a period of 2 weeks. Fibrin glue is applied to the surgically prepared recipient's cornea and in one fluid motion, the composite graft within the amnion ring construct is transferred from culture and positioned onto the graft bed. The required size is cut out at the level of the limbus by means of a trephine and/or microsurgical scissors. The lightweight, plastic interlockable ring offered stability to the graft during culture, transport, and transplantation. The use of the standardized amniotic membrane, within the amnion ring construct, improves reproducibility of the results and therefore heralds elective surgery. Rapid transplantation of a wrinkle-free graft, using a sutureless, “no touch" technique was achieved and this allowed precise tailoring of the graft to the recipient bed. This is the first time a standardized, clinical grade protocol has been described for manufacturing limbal epithelial grafts with an efficient surgical technique that prevents postsurgical graft shrinkage and improves corneal integration. The quick, sutureless, and manipulation-free technique ensured transplantation of viable, proliferating limbal epithelial stem cells.

  11. Tendon transfer fixation: comparing a tendon to tendon technique vs. bioabsorbable interference-fit screw fixation.

    PubMed

    Sabonghy, Eric Peter; Wood, Robert Michael; Ambrose, Catherine Glauber; McGarvey, William Christopher; Clanton, Thomas Oscar

    2003-03-01

    Tendon transfer techniques in the foot and ankle are used for tendon ruptures, deformities, and instabilities. This fresh cadaver study compares the tendon fixation strength in 10 paired specimens by performing a tendon to tendon fixation technique or using 7 x 20-25 mm bioabsorbable interference-fit screw tendon fixation technique. Load at failure of the tendon to tendon fixation method averaged 279N (Standard Deviation 81N) and the bioabsorbable screw 148N (Standard Deviation 72N) [p = 0.0008]. Bioabsorbable interference-fit screws in these specimens show decreased fixation strength relative to the traditional fixation technique. However, the mean bioabsorbable screw fixation strength of 148N provides physiologic strength at the tendon-bone interface.

  12. Assessment of Snared-Loop Technique When Standard Retrieval of Inferior Vena Cava Filters Fails

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doody, Orla, E-mail: orla_doody@hotmail.com; Noe, Geertje; Given, Mark F.

    Purpose To identify the success and complications related to a variant technique used to retrieve inferior vena cava filters when simple snare approach has failed. Methods A retrospective review of all Cook Guenther Tulip filters and Cook Celect filters retrieved between July 2006 and February 2008 was performed. During this period, 130 filter retrievals were attempted. In 33 cases, the standard retrieval technique failed. Retrieval was subsequently attempted with our modified retrieval technique. Results The retrieval was successful in 23 cases (mean dwell time, 171.84 days; range, 5-505 days) and unsuccessful in 10 cases (mean dwell time, 162.2 days; range,more » 94-360 days). Our filter retrievability rates increased from 74.6% with the standard retrieval method to 92.3% when the snared-loop technique was used. Unsuccessful retrieval was due to significant endothelialization (n = 9) and caval penetration by the filter (n = 1). A single complication occurred in the group, in a patient developing pulmonary emboli after attempted retrieval. Conclusion The technique we describe increased the retrievability of the two filters studied. Hook endothelialization is the main factor resulting in failed retrieval and continues to be a limitation with these filters.« less

  13. Intraoperative laryngeal electromyography in children with vocal fold immobility: a simplified technique.

    PubMed

    Scott, Andrew R; Chong, Peter Siao Tick; Randolph, Gregory W; Hartnick, Christopher J

    2008-01-01

    The primary objective of this study was to determine whether a simplified technique for intraoperative laryngeal electromyography was feasible using standard nerve integrity monitoring electrodes and audiovisual digital recording equipment. Our secondary objective was to determine if laryngeal electromyography data provided any additional information that significantly influenced patient management. Between February 2006 and February 2007, 10 children referred to our institution with vocal fold immobility underwent intraoperative laryngeal electromyography of the thyroarytenoid muscles. A retrospective chart review of these 10 patients was performed after institutional review board approval. Standard nerve integrity monitoring electrodes can be used to perform intraoperative laryngeal electromyography of the thyroarytenoid muscles in children. In 5 of 10 cases reviewed, data from laryngeal electromyography recordings meaningfully influenced the care of children with vocal fold immobility and affected clinical decision-making, sometimes altering management strategies. In the remaining 5 children, data supported clinical impressions but did not alter treatment plans. Two children with idiopathic bilateral vocal fold paralysis initially presented with a lack of electrical activity on one or both sides but went on to develop motor unit action potentials that preceded recovery of motion in both vocal folds. Our findings suggest that standard nerve monitoring equipment can be used to perform intraoperative laryngeal electromyography and that electromyographic data can assist clinicians in the management of complex patients. Additionally, there may be a role for the use of serial intraoperative measurements in predicting recovery from vocal fold paralysis in the pediatric age group.

  14. System considerations, projected requirements and applications for aeronautical mobile satellite communications for air traffic services

    NASA Technical Reports Server (NTRS)

    Mcdonald, K. D.; Miller, C. M.; Scales, W. C.; Dement, D. K.

    1990-01-01

    The projected application and requirements in the near term (to 1995) and far term (to 2010) for aeronautical mobile services supporting air traffic control operations are addressed. The implications of these requirements on spectrum needs, and the resulting effects on the satellite design and operation are discussed. The U.S. is working with international standards and regulatory organizations to develop the necessary aviation standards, signalling protocols, and implementation methods. In the provision of aeronautical safety services, a number of critical issues were identified, including system reliability and availability, access time, channel restoration time, interoperability, pre-emption techniques, and the system network interfaces. Means for accomplishing these critical services in the aeronautical mobile satellite service (AMSS), and the various activities relating to the future provision of aeronautical safety services are addressed.

  15. System considerations, projected requirements and applications for aeronautical mobile satellite communications for air traffic services

    NASA Astrophysics Data System (ADS)

    McDonald, K. D.; Miller, C. M.; Scales, W. C.; Dement, D. K.

    The projected application and requirements in the near term (to 1995) and far term (to 2010) for aeronautical mobile services supporting air traffic control operations are addressed. The implications of these requirements on spectrum needs, and the resulting effects on the satellite design and operation are discussed. The U.S. is working with international standards and regulatory organizations to develop the necessary aviation standards, signalling protocols, and implementation methods. In the provision of aeronautical safety services, a number of critical issues were identified, including system reliability and availability, access time, channel restoration time, interoperability, pre-emption techniques, and the system network interfaces. Means for accomplishing these critical services in the aeronautical mobile satellite service (AMSS), and the various activities relating to the future provision of aeronautical safety services are addressed.

  16. Rule-based fuzzy vector median filters for 3D phase contrast MRI segmentation

    NASA Astrophysics Data System (ADS)

    Sundareswaran, Kartik S.; Frakes, David H.; Yoganathan, Ajit P.

    2008-02-01

    Recent technological advances have contributed to the advent of phase contrast magnetic resonance imaging (PCMRI) as standard practice in clinical environments. In particular, decreased scan times have made using the modality more feasible. PCMRI is now a common tool for flow quantification, and for more complex vector field analyses that target the early detection of problematic flow conditions. Segmentation is one component of this type of application that can impact the accuracy of the final product dramatically. Vascular segmentation, in general, is a long-standing problem that has received significant attention. Segmentation in the context of PCMRI data, however, has been explored less and can benefit from object-based image processing techniques that incorporate fluids specific information. Here we present a fuzzy rule-based adaptive vector median filtering (FAVMF) algorithm that in combination with active contour modeling facilitates high-quality PCMRI segmentation while mitigating the effects of noise. The FAVMF technique was tested on 111 synthetically generated PC MRI slices and on 15 patients with congenital heart disease. The results were compared to other multi-dimensional filters namely the adaptive vector median filter, the adaptive vector directional filter, and the scalar low pass filter commonly used in PC MRI applications. FAVMF significantly outperformed the standard filtering methods (p < 0.0001). Two conclusions can be drawn from these results: a) Filtering should be performed after vessel segmentation of PC MRI; b) Vector based filtering methods should be used instead of scalar techniques.

  17. A simple and rapid approach to evaluate the in vitro in vivo role of release controlling agent ethyl cellulose ether derivative polymer.

    PubMed

    Akhlaq, Muhammad; Khan, Gul Majid; Jan, Syed Umer; Wahab, Abdul; Hussain, Abid; Nawaz, Asif; Abdelkader, Hamdy

    2014-11-01

    Diclofenac sodium (DCL-Na) conventional oral tablets exhibit serious side effects when given for a longer period leading to noncompliance. Controlled release matrix tablets of diclofenac sodium were formulated using simple blending (F-1), solvent evaporation (F-2) and co-precipitation techniques (F-3). Ethocel® Standard 7 FP Premium Polymer (15%) was used as a release controlling agent. Drug release study was conducted in 7.4 pH phosphate buffer solutions as dissolution medium in vitro. Pharmacokinetic parameters were evaluated using albino rabbits. Solvent evaporation technique was found to be the best release controlling technique thereby prolonging the release rate up to 24 hours. Accelerated stability studies of the optimized test formulation (F-2) did not show any significant change (p<0.05) in the physicochemical characteristics and release rate when stored for six months. A simple and rapid method was developed for DCL-Na active moiety using HPLC-UV at 276nm. The optimized test tablets (F-2) significantly (p<0.05) exhibited peaks plasma concentration (cmax=237.66±1.98) and extended the peak time (tmax=4.63±0.24). Good in-vitro in vivo correlation was found (R(2)=0.9883) against drug absorption and drug release. The study showed that once-daily controlled release matrix tablets of DCL-Na were successfully developed using Ethocel® Standard 7 FP Premium.

  18. ANOPP programming and documentation standards document

    NASA Technical Reports Server (NTRS)

    1976-01-01

    Standards defining the requirements for preparing software for the Aircraft Noise Prediction Program (ANOPP) were given. It is the intent of these standards to provide definition, design, coding, and documentation criteria for the achievement of a unity among ANOPP products. These standards apply to all of ANOPP's standard software system. The standards encompass philosophy as well as techniques and conventions.

  19. The future of surgery in the treatment of breast cancer.

    PubMed

    Wood, William C

    2003-12-01

    The role of surgery cannot be discussed independently, but in relationship to the other modalities of treatment. Sentinel lymph node mapping and biopsy has revolutionized the role of surgery in axillary staging. Techniques of sentinel node mapping, the timing relative to chemotherapy, possible contraindications, and the necessity of completion axillary dissection are all under active investigation. The next few years will see continued changes in this important technique. Techniques of localizing clinically occult tumors are numerous and under study. These are not yet at the level of Phase III comparative trials. Induction chemotherapy has long been standard care for women with locally advanced breast cancer. It has not become standard care for Stage I or II breast cancers that meet criteria for adjuvant therapy. The ability to significantly downsize 80% of breast cancers is reason enough to make it usual practice for women who are certain to receive chemotherapy, if only for the cosmetic advantage that would accrue. Much has been made of the use of thermal ablation of small breast cancers by small probes introduced by skin puncture. In initial trials the lesions were excised after being heated or frozen. Current studies are leaving the destroyed tissue in place and following for evidence of control or recurrence. The value of this approach in terms of cosmesis is unproven, and the timing of its introduction when small tumors are being evaluated for margins and genetic markers, make it difficult to imagine broad acceptance. Finally, the role of prophylactic surgery for women at increased risk remains a difficult equation, compounded of alternatives such as chemoprevention, availability and effectiveness of surveillance techniques, and the level of fear and anxiety of the patient.

  20. Time-extended local rtPA infiltration for acutely thrombosed hemodialysis fistulas.

    PubMed

    Regus, Susanne; Lang, Werner; Heinz, Marco; Rother, Ulrich; Meyer, Alexander; Almási-Sperling, Veronika; Uder, Michael; Schmid, Axel

    2018-01-01

    This study describes results of a modified local thrombolysis technique for acutely thrombosed hemodialysis (HD) arteriovenous fistulas (AVF), which is characterized by prolonged recombinant tissue plasminogen activator (rtPA) local exposure times. Contrary to the standard lyse- and- wait (L&W) technique with local reaction times of 20-40 minutes, the modified protocol allows timing of challenging angioplasty maneuvers to the next regular working day. From February 2009 to April 2014, 84 patients on HD presented with 152 acutely thrombosed AVF. They proceeded to local thrombolysis including a single shot infiltration of rtPA, local reaction time up to 40 hours and finally percutaneous stenosis angioplasty. Success rates, major adverse events and need for temporary catheter placements (TCP) were retrospectively analyzed. The local thrombolysis time after single shot infiltration was 18.6 ± 6.2 (range 2-40) hours. Mean rtPA- dosage was 2.7 mg ± 1.2. The overall success rate was 89.5% and the major complication rate was 3.3%, whereas TCP was necessary in 12.5%. The PP/SP at 1, 3, 6, 12, 18, and 24 month were 86% ± 3%/95% ± 2%, 68% ± 4%/92% ± 2%, 43% ± 4%/90% ± 2%, 28% ± 4%/82% ± 3%, 12% ± 3%/82% ± 3%, 7% ± 2%/63% ± 4%, respectively. The modified L&W technique with prolonged local rtPA reaction times is a safe and effective declotting procedure. The need for TCP was not increased and therefore comparable to the standard technique. © 2017 International Society for Hemodialysis.

  1. Validation of the Auto-Inflammatory Diseases Activity Index (AIDAI) for hereditary recurrent fever syndromes

    PubMed Central

    Piram, Maryam; Koné-Paut, Isabelle; Lachmann, Helen J; Frenkel, Joost; Ozen, Seza; Kuemmerle-Deschner, Jasmin; Stojanov, Silvia; Simon, Anna; Finetti, Martina; Sormani, Maria Pia; Martini, Alberto; Gattorno, Marco; Ruperto, Nicolino

    2014-01-01

    Objectives To validate the Auto-Inflammatory Diseases Activity Index (AIDAI) in the four major hereditary recurrent fever syndromes (HRFs): familial Mediterranean fever (FMF), mevalonate kinase deficiency (MKD), tumour necrosis factor receptor-associated periodic syndrome (TRAPS) and cryopyrin-associated periodic syndromes (CAPS). Methods In 2010, an international collaboration established the content of a disease activity tool for HRFs. Patients completed a 1-month prospective diary with 12 yes/no items before a clinical appointment during which their physician assessed their disease activity by a questionnaire. Eight international experts in auto-inflammatory diseases evaluated the patient's disease activity by a blinded web evaluation and a nominal group technique consensus conference, with their consensus judgement considered the gold standard. Sensitivity/specificity/accuracy measures and the ability of the score to discriminate active from inactive patients via the best cut-off score were calculated by a receiver operating characteristic analysis. Results Consensus was achieved for 98/106 (92%) cases (39 FMF, 35 CAPS, 14 TRAPS and 10 MKD), with 26 patients declared as having inactive disease and 72 as having active disease. The median total AIDAI score was 14 (range=0–175). An AIDAI cut-off score ≥9 discriminated active from inactive patients, with sensitivity/specificity/accuracy of 89%/92%/90%, respectively, and an area under the curve of 98% (95% CI 96% to 100%). Conclusions The AIDAI score is a valid and simple tool for assessing disease activity in FMF/MKD/TRAPS/CAPS. This tool is easy to use in clinical practice and has the potential to be used as the standard efficacy measure in future clinical trials. PMID:24026675

  2. Review of model sensor studies on Pd/SnO2(110) surfaces

    NASA Technical Reports Server (NTRS)

    Fryberger, Teresa B.; Semancik, Steve

    1990-01-01

    Studies performed at the National Institute of Standards and Technology on the model gas sensor system, Pd/SnO2(110), are reviewed. Adsorption and interfacial effects play a primary role in the gas sensing process, as they do in catalysis. For this reason, researchers have used a variety of surface sensitive techniques in the research, including x ray and ultraviolet photoelectron spectroscopies (XPS and UPS), low energy electron diffraction (LEED), and ion scattering spectroscopy (ISS). By combining these complementary techniques with in situ gas response (conductance) measurements, researchers were able to correlate directly sensor activity with the composition and structure of the Pd/SnO2 interface. Although the intent of this work is to develop an understanding of gas sensing mechanisms, its relevance to Pt/SnO2 catalytic systems is obvious.

  3. Gall-bladder and colonic retention of SeHCAT: a re-evaluation.

    PubMed

    Merrick, M V

    1994-09-01

    A number of suggested alternatives and emendations to the 7-day SeHCAT retention test have been compared with whole-body counting. It was found that correction for colonic retention is an unnecessary complication in patients with diarrhoea and that imaging either of the gall-bladder or of the distribution of activity in the intestines at 24 h does not add useful information to the standard 7-day retention measurement. Neither could the patterns of colonic uptake identified in patients following extensive ideal resection or radiotherapy be reproduced in patients with idiopathic diarrhoea. Sadly it must be concluded that neither of these shortened techniques is of clinical value in patients with intact small bowel and that there remains no reliable alternative to the 7-day Se HCAT retention test. The simplest technique the best.

  4. INcreasing Security and Protection through Infrastructure REsilience: The INSPIRE Project

    NASA Astrophysics Data System (ADS)

    D'Antonio, Salvatore; Romano, Luigi; Khelil, Abdelmajid; Suri, Neeraj

    The INSPIRE project aims at enhancing the European potential in the field of security by ensuring the protection of critical information infrastructures through (a) the identification of their vulnerabilities and (b) the development of innovative techniques for securing networked process control systems. To increase the resilience of such systems INSPIRE will develop traffic engineering algorithms, diagnostic processes and self-reconfigurable architectures along with recovery techniques. Hence, the core idea of the INSPIRE project is to protect critical information infrastructures by appropriately configuring, managing, and securing the communication network which interconnects the distributed control systems. A working prototype will be implemented as a final demonstrator of selected scenarios. Controls/Communication Experts will support project partners in the validation and demonstration activities. INSPIRE will also contribute to standardization process in order to foster multi-operator interoperability and coordinated strategies for securing lifeline systems.

  5. Simultaneous recording of electrical activity and the underlying ionic currents in NG108-15 cells cultured on gold substrate.

    PubMed

    Acosta-García, Ma Cristina; Morales-Reyes, Israel; Jiménez-Anguiano, Anabel; Batina, Nikola; Castellanos, N P; Godínez-Fernández, R

    2018-02-01

    This paper shows the simultaneous recording of electrical activity and the underlying ionic currents by using a gold substrate to culture NG108-15 cells. Cells grown on two different substrates (plastic Petri dishes and gold substrates) were characterized quantitatively through scanning electron microscopy (SEM) as well as qualitatively by optical and atomic force microscopy (AFM). No significant differences were observed between the surface area of cells cultured on gold substrates and Petri dishes, as indicated by measurements performed on SEM images. We also evaluated the electrophysiological compatibility of the cells through standard patch-clamp experiments by analyzing features such as the resting potential, membrane resistance, ionic currents, etc. Cells grown on both substrates showed no significant differences in their dependency on voltage, as well as in the magnitude of the Na+ and K+ current density; however, cells cultured on the gold substrate showed a lower membrane capacitance when compared to those grown on Petri dishes. By using two separate patch-clamp amplifiers, we were able to record the membrane current with the conventional patch-clamp technique and through the gold substrate simultaneously. Furthermore, the proposed technique allowed us to obtain simultaneous recordings of the electrical activity (such as action potentials firing) and the underlying membrane ionic currents. The excellent conductivity of gold makes it possible to overcome important difficulties found in conventional electrophysiological experiments such as those presented by the resistance of the electrolytic bath solution. We conclude that the technique here presented constitutes a solution to the problem of the simultaneous recording of electrical activity and the underlying ionic currents, which for decades, had been solved only partially.

  6. Comparison of spectral radiance responsivity calibration techniques used for backscatter ultraviolet satellite instruments

    NASA Astrophysics Data System (ADS)

    Kowalewski, M. G.; Janz, S. J.

    2015-02-01

    Methods of absolute radiometric calibration of backscatter ultraviolet (BUV) satellite instruments are compared as part of an effort to minimize pre-launch calibration uncertainties. An internally illuminated integrating sphere source has been used for the Shuttle Solar BUV, Total Ozone Mapping Spectrometer, Ozone Mapping Instrument, and Global Ozone Monitoring Experiment 2 using standardized procedures traceable to national standards. These sphere-based spectral responsivities agree to within the derived combined standard uncertainty of 1.87% relative to calibrations performed using an external diffuser illuminated by standard irradiance sources, the customary spectral radiance responsivity calibration method for BUV instruments. The combined standard uncertainty for these calibration techniques as implemented at the NASA Goddard Space Flight Center’s Radiometric Calibration and Development Laboratory is shown to less than 2% at 250 nm when using a single traceable calibration standard.

  7. BioBrick assembly standards and techniques and associated software tools.

    PubMed

    Røkke, Gunvor; Korvald, Eirin; Pahr, Jarle; Oyås, Ove; Lale, Rahmi

    2014-01-01

    The BioBrick idea was developed to introduce the engineering principles of abstraction and standardization into synthetic biology. BioBricks are DNA sequences that serve a defined biological function and can be readily assembled with any other BioBrick parts to create new BioBricks with novel properties. In order to achieve this, several assembly standards can be used. Which assembly standards a BioBrick is compatible with, depends on the prefix and suffix sequences surrounding the part. In this chapter, five of the most common assembly standards will be described, as well as some of the most used assembly techniques, cloning procedures, and a presentation of the available software tools that can be used for deciding on the best method for assembling of different BioBricks, and searching for BioBrick parts in the Registry of Standard Biological Parts database.

  8. The effect of micro-electric current and other activation techniques on dissolution abilities of sodium hypochlorite in bovine tissues.

    PubMed

    Ertuğrul, İhsan Furkan; Maden, Murat; Orhan, Ekim Onur; Özkorucuklu, Sabriye Perçin

    2015-12-18

    The aim of the study was to evaluate the effects of micro-electric current on sodium hypochlorite's (NaOCl's) tissue-dissolution abilities, compared with other activation methods, including sonic, ultrasonic, pipetting, and temperature. Bovine muscle tissues (n = 154) with standard sizes and weights were prepared and divided into two temperature groups: room temperature and 45 °C. Each temperature group was divided into seven sub-groups by activation methods: D = distilled water (-control); NaOCl = 5.25 % passive NaOCl (+ control); P = 5.25 % NaOCl with pipetting; SA = 5.25 % NaOCl with sonic activation; UA = 5.25 % NaOCl with ultrasonic activation; E-NaOCl = 5.25 % NaOCl with micro-electric current; and E-NaOCl + P = 5.25 % NaOCl with micro-electric current and pipetting. Specimens were weighed before and after treatment. Average, standard deviation, minimum, maximum, and median were calculated for each group. Resulting data were analyzed statistically using multi-way ANOVA and Tukey HSD tests. The level of the alpha-type error was set at < 0.05. At room temperature, the E-NaOCl + P group dissolved the highest amount of tissue (p < 0.05), and the UA, SA, and P groups dissolved significantly higher amounts of tissue than did the positive control or E-NaOCl groups (p < 0.05). At 45 °C, there was no significant difference between the SA and E-NaOCl groups (p > 0.05), and the E-NaOCl + P group dissolved a higher amount of tissue than any other group (p < 0.05). Using NaOCl with micro-electric current can improve the tissue-dissolving ability of the solution. In addition, this method can be combined with additional techniques, such as heating and/or pipetting, to achieve a synergistic effect of NaOCl on tissue dissolution.

  9. Advanced Undergraduate Experiments in Thermoanalytical Chemistry.

    ERIC Educational Resources Information Center

    Hill, J. O.; Magee, R. J.

    1988-01-01

    Describes several experiments using the techniques of thermal analysis and thermometric titrimetry. Defines thermal analysis and several recent branches of the technique. Notes most of the experiments use simple equipment and standard laboratory techniques. (MVL)

  10. Optimisation of radiation dose and image quality in mobile neonatal chest radiography.

    PubMed

    Hinojos-Armendáriz, V I; Mejía-Rosales, S J; Franco-Cabrera, M C

    2018-05-01

    To optimise the radiation dose and image quality for chest radiography in the neonatal intensive care unit (NICU) by increasing the mean beam energy. Two techniques for the acquisition of NICU AP chest X-ray images were compared for image quality and radiation dose. 73 images were acquired using a standard technique (56 kV, 3.2 mAs and no additional filtration) and 90 images with a new technique (62 kV, 2 mAs and 2 mm Al filtration). The entrance surface air kerma (ESAK) was measured using a phantom and compared between the techniques and against established diagnostic reference levels (DRL). Images were evaluated using seven image quality criteria independently by three radiologists. Images quality and radiation dose were compared statistically between the standard and new techniques. The maximum ESAK for the new technique was 40.20 μGy, 43.7% of the ESAK of the standard technique. Statistical evaluation demonstrated no significant differences in image quality between the two acquisition techniques. Based on the techniques and acquisition factors investigated within this study, it is possible to lower the radiation dose without any significant effects on image quality by adding filtration (2 mm Al) and increasing the tube potential. Such steps are relatively simple to undertake and as such, other departments should consider testing and implementing this dose reduction strategy within clinical practice where appropriate. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

  11. Methodology to estimate particulate matter emissions from certified commercial aircraft engines.

    PubMed

    Wayson, Roger L; Fleming, Gregg G; Lovinelli, Ralph

    2009-01-01

    Today, about one-fourth of U.S. commercial service airports, including 41 of the busiest 50, are either in nonattainment or maintenance areas per the National Ambient Air Quality Standards. U.S. aviation activity is forecasted to triple by 2025, while at the same time, the U.S. Environmental Protection Agency (EPA) is evaluating stricter particulate matter (PM) standards on the basis of documented human health and welfare impacts. Stricter federal standards are expected to impede capacity and limit aviation growth if regulatory mandated emission reductions occur as for other non-aviation sources (i.e., automobiles, power plants, etc.). In addition, strong interest exists as to the role aviation emissions play in air quality and climate change issues. These reasons underpin the need to quantify and understand PM emissions from certified commercial aircraft engines, which has led to the need for a methodology to predict these emissions. Standardized sampling techniques to measure volatile and nonvolatile PM emissions from aircraft engines do not exist. As such, a first-order approximation (FOA) was derived to fill this need based on available information. FOA1.0 only allowed prediction of nonvolatile PM. FOA2.0 was a change to include volatile PM emissions on the basis of the ratio of nonvolatile to volatile emissions. Recent collaborative efforts by industry (manufacturers and airlines), research establishments, and regulators have begun to provide further insight into the estimation of the PM emissions. The resultant PM measurement datasets are being analyzed to refine sampling techniques and progress towards standardized PM measurements. These preliminary measurement datasets also support the continued refinement of the FOA methodology. FOA3.0 disaggregated the prediction techniques to allow for independent prediction of nonvolatile and volatile emissions on a more theoretical basis. The Committee for Aviation Environmental Protection of the International Civil Aviation Organization endorsed the use of FOA3.0 in February 2007. Further commitment was made to improve the FOA as new data become available, until such time the methodology is rendered obsolete by a fully validated database of PM emission indices for today's certified commercial fleet. This paper discusses related assumptions and derived equations for the FOA3.0 methodology used worldwide to estimate PM emissions from certified commercial aircraft engines within the vicinity of airports.

  12. Comparative study of navigated versus freehand osteochondral graft transplantation of the knee.

    PubMed

    Koulalis, Dimitrios; Di Benedetto, Paolo; Citak, Mustafa; O'Loughlin, Padhraig; Pearle, Andrew D; Kendoff, Daniel O

    2009-04-01

    Osteochondral lesions are a common sports-related injury for which osteochondral grafting, including mosaicplasty, is an established treatment. Computer navigation has been gaining popularity in orthopaedic surgery to improve accuracy and precision. Navigation improves angle and depth matching during harvest and placement of osteochondral grafts compared with conventional freehand open technique. Controlled laboratory study. Three cadaveric knees were used. Reference markers were attached to the femur, tibia, and donor/recipient site guides. Fifteen osteochondral grafts were harvested and inserted into recipient sites with computer navigation, and 15 similar grafts were inserted freehand. The angles of graft removal and placement as well as surface congruity (graft depth) were calculated for each surgical group. The mean harvesting angle at the donor site using navigation was 4 degrees (standard deviation, 2.3 degrees ; range, 1 degrees -9 degrees ) versus 12 degrees (standard deviation, 5.5 degrees ; range, 5 degrees -24 degrees ) using freehand technique (P < .0001). The recipient plug removal angle using the navigated technique was 3.3 degrees (standard deviation, 2.1 degrees ; range, 0 degrees -9 degrees ) versus 10.7 degrees (standard deviation, 4.9 degrees ; range, 2 degrees -17 degrees ) in freehand (P < .0001). The mean navigated recipient plug placement angle was 3.6 degrees (standard deviation, 2.0 degrees ; range, 1 degrees -9 degrees ) versus 10.6 degrees (standard deviation, 4.4 degrees ; range, 3 degrees -17 degrees ) with freehand technique (P = .0001). The mean height of plug protrusion under navigation was 0.3 mm (standard deviation, 0.2 mm; range, 0-0.6 mm) versus 0.5 mm (standard deviation, 0.3 mm; range, 0.2-1.1 mm) using a freehand technique (P = .0034). Significantly greater accuracy and precision were observed in harvesting and placement of the osteochondral grafts in the navigated procedures. Clinical studies are needed to establish a benefit in vivo. Improvement in the osteochondral harvest and placement is desirable to optimize clinical outcomes. Navigation shows great potential to improve both harvest and placement precision and accuracy, thus optimizing ultimate surface congruity.

  13. A semi-automatic technique to quantify complex tuberculous lung lesions on 18F-fluorodeoxyglucose positron emission tomography/computerised tomography images.

    PubMed

    Malherbe, Stephanus T; Dupont, Patrick; Kant, Ilse; Ahlers, Petri; Kriel, Magdalena; Loxton, André G; Chen, Ray Y; Via, Laura E; Thienemann, Friedrich; Wilkinson, Robert J; Barry, Clifton E; Griffith-Richards, Stephanie; Ellman, Annare; Ronacher, Katharina; Winter, Jill; Walzl, Gerhard; Warwick, James M

    2018-06-25

    There is a growing interest in the use of 18 F-FDG PET-CT to monitor tuberculosis (TB) treatment response. However, TB causes complex and widespread pathology, which is challenging to segment and quantify in a reproducible manner. To address this, we developed a technique to standardise uptake (Z-score), segment and quantify tuberculous lung lesions on PET and CT concurrently, in order to track changes over time. We used open source tools and created a MATLAB script. The technique was optimised on a training set of five pulmonary tuberculosis (PTB) cases after standard TB therapy and 15 control patients with lesion-free lungs. We compared the proposed method to a fixed threshold (SUV > 1) and manual segmentation by two readers and piloted the technique successfully on scans of five control patients and five PTB cases (four cured and one failed treatment case), at diagnosis and after 1 and 6 months of treatment. There was a better correlation between the Z-score-based segmentation and manual segmentation than SUV > 1 and manual segmentation in terms of overall spatial overlap (measured in Dice similarity coefficient) and specificity (1 minus false positive volume fraction). However, SUV > 1 segmentation appeared more sensitive. Both the Z-score and SUV > 1 showed very low variability when measuring change over time. In addition, total glycolytic activity, calculated using segmentation by Z-score and lesion-to-background ratio, correlated well with traditional total glycolytic activity calculations. The technique quantified various PET and CT parameters, including the total glycolytic activity index, metabolic lesion volume, lesion volumes at different CT densities and combined PET and CT parameters. The quantified metrics showed a marked decrease in the cured cases, with changes already apparent at month one, but remained largely unchanged in the failed treatment case. Our technique is promising to segment and quantify the lung scans of pulmonary tuberculosis patients in a semi-automatic manner, appropriate for measuring treatment response. Further validation is required in larger cohorts.

  14. Early institution of pre-cutting for difficult biliary cannulation: a prospective study comparing conventional vs. a modified technique.

    PubMed

    Kaffes, Arthur J; Sriram, Parupudi V J; Rao, Guduru V; Santosh, Darisetti; Reddy, D Nageshwar

    2005-11-01

    Pre-cutting techniques have been used to gain biliary access at the expense of an increased complication rate. This may be because of the multiple attempts to achieve cannulation by using standard methods before pre-cutting and causing excess edema and papillary trauma. There are limited data on the early use of pre-cutting techniques. We performed a prospective study of the early introduction of needle-knife techniques in patients with difficult biliary cannulation. Standard biliary cannulation was attempted with a sphincterotome and a guidewire. If this failed within 10 minutes or if there were more than 5 pancreatic cannulations, the needle-knife technique was used. Either a standard method of pre-cutting (below-upward) from the papillary orifice or the modified technique of pre-cutting (above-downward), stopping short of the papillary orifice, was adopted, as per the discretion of the endoscopist. If pre-cutting failed, the cannulation was reattempted 24 to 48 hours later. A total of 346 therapeutic biliary ERCP procedures were performed between April and August 2003. Of these, 70 patients (20%) (mean age, 54 years; 38 men) underwent needle-knife pre-cut sphincterotomy (16 with the standard technique). In 58 patients (83%), the procedure was successful with the initial pre-cutting, making the total success at initial ERCP 334/346 (96.5%). Nine patients in whom pre-cut failed, returned for a second-attempt ERCP, with 7 completed successfully. The total success rate of pre-cutting was 65/70 (93%). The overall success rate of biliary cannulation, after two ERCP attempts, was 341/346 (98.5%). Six patients had mild bleeding, and one had mild pancreatitis. There was no difference in these complications between the two types of pre-cut techniques. The early use of needle knife for difficult biliary cannulation is safe and effective, irrespective of the technique used.

  15. Characterizing Protein Interactions Employing a Genome-Wide siRNA Cellular Phenotyping Screen

    PubMed Central

    Suratanee, Apichat; Schaefer, Martin H.; Betts, Matthew J.; Soons, Zita; Mannsperger, Heiko; Harder, Nathalie; Oswald, Marcus; Gipp, Markus; Ramminger, Ellen; Marcus, Guillermo; Männer, Reinhard; Rohr, Karl; Wanker, Erich; Russell, Robert B.; Andrade-Navarro, Miguel A.; Eils, Roland; König, Rainer

    2014-01-01

    Characterizing the activating and inhibiting effect of protein-protein interactions (PPI) is fundamental to gain insight into the complex signaling system of a human cell. A plethora of methods has been suggested to infer PPI from data on a large scale, but none of them is able to characterize the effect of this interaction. Here, we present a novel computational development that employs mitotic phenotypes of a genome-wide RNAi knockdown screen and enables identifying the activating and inhibiting effects of PPIs. Exemplarily, we applied our technique to a knockdown screen of HeLa cells cultivated at standard conditions. Using a machine learning approach, we obtained high accuracy (82% AUC of the receiver operating characteristics) by cross-validation using 6,870 known activating and inhibiting PPIs as gold standard. We predicted de novo unknown activating and inhibiting effects for 1,954 PPIs in HeLa cells covering the ten major signaling pathways of the Kyoto Encyclopedia of Genes and Genomes, and made these predictions publicly available in a database. We finally demonstrate that the predicted effects can be used to cluster knockdown genes of similar biological processes in coherent subgroups. The characterization of the activating or inhibiting effect of individual PPIs opens up new perspectives for the interpretation of large datasets of PPIs and thus considerably increases the value of PPIs as an integrated resource for studying the detailed function of signaling pathways of the cellular system of interest. PMID:25255318

  16. Ecobat: An online resource to facilitate transparent, evidence-based interpretation of bat activity data.

    PubMed

    Lintott, Paul R; Davison, Sophie; van Breda, John; Kubasiewicz, Laura; Dowse, David; Daisley, Jonathan; Haddy, Emily; Mathews, Fiona

    2018-01-01

    Acoustic surveys of bats are one of the techniques most commonly used by ecological practitioners. The results are used in Ecological Impact Assessments to assess the likely impacts of future developments on species that are widely protected in law, and to monitor developments' postconstruction. However, there is no standardized methodology for analyzing or interpreting these data, which can make the assessment of the ecological value of a site very subjective. Comparisons of sites and projects are therefore difficult for ecologists and decision-makers, for example, when trying to identify the best location for a new road based on relative bat activity levels along alternative routes. Here, we present a new web-based, data-driven tool, Ecobat, which addresses the need for a more robust way of interpreting ecological data. Ecobat offers users an easy, standardized, and objective method for analyzing bat activity data. It allows ecological practitioners to compare bat activity data at regional and national scales and to generate a numerical indicator of the relative importance of a night's worth of bat activity. The tool is free and open-source; because the underlying algorithms are already developed, it could easily be expanded to new geographical regions and species. Data donation is required to ensure the robustness of the analyses; we use a positive feedback mechanism to encourage ecological practitioners to share data by providing in return high quality, contextualized data analysis, and graphical visualizations for direct use in ecological reports.

  17. Identification of new potent inhibitor of aldose reductase from Ocimum basilicum.

    PubMed

    Bhatti, Huma Aslam; Tehseen, Yildiz; Maryam, Kiran; Uroos, Maliha; Siddiqui, Bina S; Hameed, Abdul; Iqbal, Jamshed

    2017-12-01

    Recent efforts to develop cure for chronic diabetic complications have led to the discovery of potent inhibitors against aldose reductase (AKR1B1, EC 1.1.1.21) whose role in diabetes is well-evident. In the present work, two new natural products were isolated from the ariel part of Ocimum basilicum; 7-(3-hydroxypropyl)-3-methyl-8-β-O-d-glucoside-2H-chromen-2-one (1) and E-4-(6'-hydroxyhex-3'-en-1-yl)phenyl propionate (2) and confirmed their structures with different spectroscopic techniques including NMR spectroscopy etc. The isolated compounds (1, 2) were evaluated for in vitro inhibitory activity against aldose reductase (AKR1B1) and aldehyde reductase (AKR1A1). The natural product (1) showed better inhibitory activity for AKR1B1 with IC 50 value of 2.095±0.77µM compare to standard sorbinil (IC 50 =3.14±0.02µM). Moreover, the compound (1) also showed multifolds higher activity (IC 50 =0.783±0.07µM) against AKR1A1 as compared to standard valproic acid (IC 50 =57.4±0.89µM). However, the natural product (2) showed slightly lower activity for AKR1B1 (IC 50 =4.324±1.25µM). Moreover, the molecular docking studies of the potent inhibitors were also performed to identify the putative binding modes within the active site of aldose/aldehyde reductases. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Study of dietary supplements compositions by neutron activation analysis at the VR-1 training reactor

    NASA Astrophysics Data System (ADS)

    Stefanik, Milan; Rataj, Jan; Huml, Ondrej; Sklenka, Lubomir

    2017-11-01

    The VR-1 training reactor operated by the Czech Technical University in Prague is utilized mainly for education of students and training of various reactor staff; however, R&D is also carried out at the reactor. The experimental instrumentation of the reactor can be used for the irradiation experiments and neutron activation analysis. In this paper, the neutron activation analysis (NAA) is used for a study of dietary supplements containing the zinc (one of the essential trace elements for the human body). This analysis includes the dietary supplement pills of different brands; each brand is represented by several different batches of pills. All pills were irradiated together with the standard activation etalons in the vertical channel of the VR-1 reactor at the nominal power (80 W). Activated samples were investigated by the nuclear gamma-ray spectrometry technique employing the semiconductor HPGe detector. From resulting saturated activities, the amount of mineral element (Zn) in the pills was determined using the comparative NAA method. The results show clearly that the VR-1 training reactor is utilizable for neutron activation analysis experiments.

  19. SVM-based multi-sensor fusion for free-living physical activity assessment.

    PubMed

    Liu, Shaopeng; Gao, Robert X; John, Dinesh; Staudenmayer, John; Freedson, Patty S

    2011-01-01

    This paper presents a sensor fusion method for assessing physical activity (PA) of human subjects, based on the support vector machines (SVMs). Specifically, acceleration and ventilation measured by a wearable multi-sensor device on 50 test subjects performing 13 types of activities of varying intensities are analyzed, from which the activity types and related energy expenditures are derived. The result shows that the method correctly recognized the 13 activity types 84.7% of the time, which is 26% higher than using a hip accelerometer alone. Also, the method predicted the associated energy expenditure with a root mean square error of 0.43 METs, 43% lower than using a hip accelerometer alone. Furthermore, the fusion method was effective in reducing the subject-to-subject variability (standard deviation of recognition accuracies across subjects) in activity recognition, especially when data from the ventilation sensor was added to the fusion model. These results demonstrate that the multi-sensor fusion technique presented is more effective in assessing activities of varying intensities than the traditional accelerometer-alone based methods.

  20. Behavior of autologous indium-114m-labeled lymphocytes in patients with lymphoid cell malignancy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hamilton, D.; Cowan, R.A.; Sharma, H.L.

    1988-04-01

    It has been shown that radioactive material can be localized to lymphocyte traffic areas using radiolabeled autologous lymphocytes and that /sup 114m/In deposited in such a way in rats produces a lymphopoenia by establishing a selective internal irradiation of circulating lymphocytes. The study reported here was undertaken to investigate the feasibility of using this technique in patients with lymphoid cell malignancy. Up to 22.7 MBq was administered to seven patients with active non-Hodgkin's lymphoma involving the spleen and the behavior of the radioactive material was followed over subsequent months. Estimates of the activity in peripheral blood, bone marrow, excreta samples,more » and of the variation in the whole-body distribution were obtained. The administered radioactive material cleared rapidly from the blood, 85% being removed within the first 30 min. There was an almost immediate uptake of most of this by the spleen and liver with less than 5% of administered activity accumulating in the bone marrow. After 48 hr, the whole-body distribution changed only slowly and there was a regular decrease of the activity in the spleen. Excretion of radioactive material occurred via both the urine and feces and amounted to less than 1% of administered activity per day. This pharmacokinetic data was used to calculate radiation absorbed doses to various organs for a standard man. It is concluded that this represents a feasible technique for the targeting of radioactive material for the treatment of lymphoid malignancy.« less

  1. Monte-Carlo simulations of neutron-induced activation in a Fast-Neutron and Gamma-Based Cargo Inspection System

    NASA Astrophysics Data System (ADS)

    Bromberger, B.; Bar, D.; Brandis, M.; Dangendorf, V.; Goldberg, M. B.; Kaufmann, F.; Mor, I.; Nolte, R.; Schmiedel, M.; Tittelmeier, K.; Vartsky, D.; Wershofen, H.

    2012-03-01

    An air cargo inspection system combining two nuclear reaction based techniques, namely Fast-Neutron Resonance Radiography and Dual-Discrete-Energy Gamma Radiography is currently being developed. This system is expected to allow detection of standard and improvised explosives as well as special nuclear materials. An important aspect for the applicability of nuclear techniques in an airport inspection facility is the inventory and lifetimes of radioactive isotopes produced by the neutron radiation inside the cargo, as well as the dose delivered by these isotopes to people in contact with the cargo during and following the interrogation procedure. Using MCNPX and CINDER90 we have calculated the activation levels for several typical inspection scenarios. One example is the activation of various metal samples embedded in a cotton-filled container. To validate the simulation results, a benchmark experiment was performed, in which metal samples were activated by fast-neutrons in a water-filled glass jar. The induced activity was determined by analyzing the gamma spectra. Based on the calculated radioactive inventory in the container, the dose levels due to the induced gamma radiation were calculated at several distances from the container and in relevant time windows after the irradiation, in order to evaluate the radiation exposure of the cargo handling staff, air crew and passengers during flight. The possibility of remanent long-lived radioactive inventory after cargo is delivered to the client is also of concern and was evaluated.

  2. Effectiveness of Sonic, Ultrasonic, and Photon-Induced Photoacoustic Streaming Activation of NaOCl on Filling Material Removal Following Retreatment in Oval Canal Anatomy.

    PubMed

    Jiang, Shan; Zou, Ting; Li, Dongxia; Chang, Jeffery W W; Huang, Xiaojing; Zhang, Chengfei

    2016-01-01

    This study aimed to assess the effectiveness of sonic, ultrasonic and laser [photon-induced photoacoustic streaming (PIPS)] irrigation activation in removing filling remnants from oval root canals after standard canal retreatment procedures with the ProTaper universal rotary retreatment system. Twenty-eight maxillary first premolars were instrumented with ProTaper NiTi rotary instruments and obturated with gutta-percha and AH Plus sealer using the continuous wave of condensation technique. After storage at 37°C and 100% humidity for 1 week, the specimens were retreated with the ProTaper universal retreatment system for the removal of filling material. Teeth were then randomly assigned into four groups (n = 7): group 1, positive control; group 2, retreated with sonic irrigation; group 3, retreated with ultrasonic irrigation; and group 4, retreated with laser irradiation. The specimens were scanned using micro-CT before instrumentation, after obturation and mechanical retreatment, and after additional activation procedures. The percentage volume of the filling remnants was measured. Specimens were split longitudinally after micro-CT scan, canal walls were examined using scanning electron microscopy (SEM), and the amount of residual filling material was scored. The filling materials' removal efficacy in the three experimental groups was higher than that of the control group (p < 0.05), whereas filling materials ranging from 1.46 ± 0.30 to 2.21 ± 0.46 mm(3) remained in the canal in all three experimental groups. Additionally, there was a significantly greater reduction in the amount of filling remnants in the PIPS group than in the sonic and ultrasonic groups (both p < 0.05), and significantly greater reduction in the ultrasonic group than the sonic group (p < 0.05). Activation of NaOCl with PIPS showed significantly better performance than sonic and ultrasonic techniques in removing the filling remnants following mechanical retreatment of oval root canals. The ultrasonic technique also performed better than the sonic technique. However, none of the additional activation procedures was able to completely eliminate the filling remnants.

  3. Perfect Mirror Design Technology

    DTIC Science & Technology

    1999-02-01

    with Prof. Mario Molina, recipient of the 1995 Nobel Prize in Chemistry. The partnership, along with Aerodyne Research Inc., looked at how sulfur...Corporation is developing standards for nondestructive evaluation ( NDE ) techniques for industry use. Use of the new standards will result in improved...novel testing methodology that dramatically improves the accuracy of NDE techniques used to detect flaws. Basic Research Five years ago, the main

  4. Standardized reporting of resection technique during nephron-sparing surgery: the surface-intermediate-base margin score.

    PubMed

    Minervini, Andrea; Carini, Marco; Uzzo, Robert G; Campi, Riccardo; Smaldone, Marc C; Kutikov, Alexander

    2014-11-01

    A standardized reporting system of nephron-sparing surgery resection techniques is lacking. The surface-intermediate-base scoring system represents a formal reporting instrument to assist in interpretation of reported data and to facilitate comparisons in the urologic literature. Copyright © 2014 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahadi, S., E-mail: su4idi@yahoo.com; Puspito, N. T.; Ibrahim, G.

    Determination of onset time precursors of strong earthquakes (Mw > 5) and distance (d < 500 km) using geomagnetic data from Geomagnetic station KTB, Sumatra and two station references DAV, Philippine and DAW, Australia. separate techniques are required in its determination. Not the same as that recorded in the kinetic wave seismograms can be determined by direct time domain. Difficulties associated with electromagnetic waves seismogenic activities require analysis of the transformed signal in the frequency domain. Determination of the frequency spectrum will determine the frequency of emissions emitted from the earthquake source. The aim is to analyze the power amplitudemore » of the ULF emissions in the horizontal component (H) and vertical component (Z). Polarization power ratio Z/H is used for determining the sign of earthquake precursors controlled by the standard deviation. The pattern recognition polarization ratio should be obtained which can differentiate emissions from seismogenic effects of geomagnetic activity. ULF emission patterns generated that seismogenic effect has duration > 5 days and the dominance of emission intensity recorded at the Z component and for the dominance of the emission intensity of geomagnetic activity recorded in the component H. The result shows that the onset time is determined when the polarization power ratio Z/H standard deviation over the limit (p ± 2 σ) which has a duration of > 5 days.« less

  6. Quantitative modeling of multiscale neural activity

    NASA Astrophysics Data System (ADS)

    Robinson, Peter A.; Rennie, Christopher J.

    2007-01-01

    The electrical activity of the brain has been observed for over a century and is widely used to probe brain function and disorders, chiefly through the electroencephalogram (EEG) recorded by electrodes on the scalp. However, the connections between physiology and EEGs have been chiefly qualitative until recently, and most uses of the EEG have been based on phenomenological correlations. A quantitative mean-field model of brain electrical activity is described that spans the range of physiological and anatomical scales from microscopic synapses to the whole brain. Its parameters measure quantities such as synaptic strengths, signal delays, cellular time constants, and neural ranges, and are all constrained by independent physiological measurements. Application of standard techniques from wave physics allows successful predictions to be made of a wide range of EEG phenomena, including time series and spectra, evoked responses to stimuli, dependence on arousal state, seizure dynamics, and relationships to functional magnetic resonance imaging (fMRI). Fitting to experimental data also enables physiological parameters to be infered, giving a new noninvasive window into brain function, especially when referenced to a standardized database of subjects. Modifications of the core model to treat mm-scale patchy interconnections in the visual cortex are also described, and it is shown that resulting waves obey the Schroedinger equation. This opens the possibility of classical cortical analogs of quantum phenomena.

  7. Active music therapy approach for stroke patients in the post-acute rehabilitation.

    PubMed

    Raglio, Alfredo; Zaliani, Alberto; Baiardi, Paola; Bossi, Daniela; Sguazzin, Cinzia; Capodaglio, Edda; Imbriani, Chiara; Gontero, Giulia; Imbriani, Marcello

    2017-05-01

    Guidelines in stroke rehabilitation recommend the use of a multidisciplinary approach. Different approaches and techniques with music are used in the stroke rehabilitation to improve motor and cognitive functions but also psychological outcomes. In this randomized controlled pilot trial, relational active music therapy approaches were tested in the post-acute phase of disease. Thirty-eight hospitalized patients with ischemic and hemorrhagic stroke were recruited and allocated in two groups. The experimental group underwent the standard of care (physiotherapy and occupational therapy daily sessions) and relational active music therapy treatments. The control group underwent the standard of care only. Motor functions and psychological aspects were assessed before and after treatments. Music therapy process was also evaluated using a specific rating scale. All groups showed a positive trend in quality of life, functional and disability levels, and gross mobility. The experimental group showed a decrease of anxiety and, in particular, of depression (p = 0.016). In addition, the strength of non-dominant hand (grip) significantly increased in the experimental group (p = 0.041). Music therapy assessment showed a significant improvement over time of non-verbal and sonorous-music relationships. Future studies, including a greater number of patients and follow-up evaluations, are needed to confirm promising results of this study.

  8. Non-standard finite difference and Chebyshev collocation methods for solving fractional diffusion equation

    NASA Astrophysics Data System (ADS)

    Agarwal, P.; El-Sayed, A. A.

    2018-06-01

    In this paper, a new numerical technique for solving the fractional order diffusion equation is introduced. This technique basically depends on the Non-Standard finite difference method (NSFD) and Chebyshev collocation method, where the fractional derivatives are described in terms of the Caputo sense. The Chebyshev collocation method with the (NSFD) method is used to convert the problem into a system of algebraic equations. These equations solved numerically using Newton's iteration method. The applicability, reliability, and efficiency of the presented technique are demonstrated through some given numerical examples.

  9. Chemically Defined Medium and Caenorhabditis elegans: A Powerful Approach

    NASA Technical Reports Server (NTRS)

    Szewczyk, N. J.; Kozak, E.; Conley, C. A.

    2003-01-01

    C. elegans has been established as a powerful genetic system. Growth in a chemically defined medium (C. elegans Maintenance Medium (CeMM)) now allows standardization and systematic manipulation of the nutrients that animals receive. Liquid cultivation allows automated culturing and experimentation and should be of me in large-scale growth and screening of animals. Here we present our initial results from developing culture systems with CeMM. We find that CeMM is versatile and culturing is simple. CeMM can be used in a solid or liquid state, it can be stored unused for at least a year, unattended actively growing cultures may be maintained longer than with standard techniques, and standard C. elegans protocols work well with animals grown in defined medium. We also find that there are caveats of using defined medium. Animals in defined medium grow more slowly than on standard medium, appear to display adaptation to the defined medium, and display altered growth rates as they change defined medium composition. As was suggested with the introduction of C. elegans as a potential genetic system, use of defined medium with C. elegans should prove a powerful tool.

  10. Fragment-based quantitative structure-activity relationship (FB-QSAR) for fragment-based drug design.

    PubMed

    Du, Qi-Shi; Huang, Ri-Bo; Wei, Yu-Tuo; Pang, Zong-Wen; Du, Li-Qin; Chou, Kuo-Chen

    2009-01-30

    In cooperation with the fragment-based design a new drug design method, the so-called "fragment-based quantitative structure-activity relationship" (FB-QSAR) is proposed. The essence of the new method is that the molecular framework in a family of drug candidates are divided into several fragments according to their substitutes being investigated. The bioactivities of molecules are correlated with the physicochemical properties of the molecular fragments through two sets of coefficients in the linear free energy equations. One coefficient set is for the physicochemical properties and the other for the weight factors of the molecular fragments. Meanwhile, an iterative double least square (IDLS) technique is developed to solve the two sets of coefficients in a training data set alternately and iteratively. The IDLS technique is a feedback procedure with machine learning ability. The standard Two-dimensional quantitative structure-activity relationship (2D-QSAR) is a special case, in the FB-QSAR, when the whole molecule is treated as one entity. The FB-QSAR approach can remarkably enhance the predictive power and provide more structural insights into rational drug design. As an example, the FB-QSAR is applied to build a predictive model of neuraminidase inhibitors for drug development against H5N1 influenza virus. (c) 2008 Wiley Periodicals, Inc.

  11. Neutron activation determination of iridium, gold, platinum, and silver in geologic samples

    USGS Publications Warehouse

    Millard, H.T.

    1987-01-01

    Low-level methods for the determination of iridium and other noble metals have become increasingly important in recent years due to interest in locating abundance anomalies associated with the Cretaceous and Tertiary (K-T) boundary. Typical iridium anomalies are in the range of 1 to 100 ??g/kg (ppb). Thus methods with detection limits near 0.1 ??g/kg should be adequate to detect K-T boundary anomalies. Radiochemical neutron activation analysis methods continue to be required although instrumental neutron activation analysis techniques employing elaborate gamma-counters are under development. In the procedure developed in this study samples irradiated in the epithermal neutron facility of the U. S. Geological Survey TRIGA Reactor (Denver, Colorado) are treated with a mini-fire assay technique. The iridium, gold, and silver are collected in a 1-gram metallic lead button. Primary contaminants at this stage are arsenic and antimony. These can be removed by heating the button with a mixture of sodium perioxide and sodium hydroxide. The resulting 0.2-gram lead bead is counted in a Compton suppression spectrometer. Carrier yields are determined by reirradiation of the lead beads. This procedure has been applied to the U.S.G.S. Standard Rock PCC-1 and samples from K-T boundary sites in the Western Interior of North America. ?? 1987 Akade??miai Kiado??.

  12. Human facial skin detection in thermal video to effectively measure electrodermal activity (EDA)

    NASA Astrophysics Data System (ADS)

    Kaur, Balvinder; Hutchinson, J. Andrew; Leonard, Kevin R.; Nelson, Jill K.

    2011-06-01

    In the past, autonomic nervous system response has often been determined through measuring Electrodermal Activity (EDA), sometimes referred to as Skin Conductance (SC). Recent work has shown that high resolution thermal cameras can passively and remotely obtain an analog to EDA by assessing the activation of facial eccrine skin pores. This paper investigates a method to distinguish facial skin from non-skin portions on the face to generate a skin-only Dynamic Mask (DM), validates the DM results, and demonstrates DM performance by removing false pore counts. Moreover, this paper shows results from these techniques using data from 20+ subjects across two different experiments. In the first experiment, subjects were presented with primary screening questions for which some had jeopardy. In the second experiment, subjects experienced standard emotion-eliciting stimuli. The results from using this technique will be shown in relation to data and human perception (ground truth). This paper introduces an automatic end-to-end skin detection approach based on texture feature vectors. In doing so, the paper contributes not only a new capability of tracking facial skin in thermal imagery, but also enhances our capability to provide non-contact, remote, passive, and real-time methods for determining autonomic nervous system responses for medical and security applications.

  13. 1983 international intercomparison of nuclear accident dosimetry systems at Oak Ridge National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Swaja, R.E.; Greene, R.T.; Sims, C.S.

    1985-04-01

    An international intercomparison of nuclear accident dosimetry systems was conducted during September 12-16, 1983, at Oak Ridge National Laboratory (ORNL) using the Health Physics Research Reactor operated in the pulse mode to simulate criticality accidents. This study marked the twentieth in a series of annual accident dosimetry intercomparisons conducted at ORNL. Participants from ten organizations attended this intercomparison and measured neutron and gamma doses at area monitoring stations and on phantoms for three different shield conditions. Results of this study indicate that foil activation techniques are the most popular and accurate method of determining accident-level neutron doses at area monitoringmore » stations. For personnel monitoring, foil activation, blood sodium activation, and thermoluminescent (TL) methods are all capable of providing accurate dose estimates in a variety of radiation fields. All participants in this study used TLD's to determine gamma doses with very good results on the average. Chemical dosemeters were also shown to be capable of yielding accurate estimates of total neutron plus gamma doses in a variety of radiation fields. While 83% of all neutron measurements satisfied regulatory standards relative to reference values, only 39% of all gamma results satisfied corresponding guidelines for gamma measurements. These results indicate that continued improvement in accident dosimetry evaluation and measurement techniques is needed.« less

  14. Ultrasound-assisted leaching-dispersive solid-phase extraction followed by liquid-liquid microextraction for the determination of polybrominated diphenyl ethers in sediment samples by gas chromatography-tandem mass spectrometry.

    PubMed

    Fontana, Ariel R; Lana, Nerina B; Martinez, Luis D; Altamirano, Jorgelina C

    2010-06-30

    Ultrasound-assisted leaching-dispersive solid-phase extraction followed by dispersive liquid-liquid microextraction (USAL-DSPE-DLLME) technique has been developed as a new analytical approach for extracting, cleaning up and preconcentrating polybrominated diphenyl ethers (PBDEs) from sediment samples prior gas chromatography-tandem mass spectrometry (GC-MS/MS) analysis. In the first place, PBDEs were leached from sediment samples by using acetone. This extract was cleaned-up by DSPE using activated silica gel as sorbent material. After clean-up, PBDEs were preconcentrated by using DLLME technique. Thus, 1 mL acetone extract (disperser solvent) and 60 microL carbon tetrachloride (extraction solvent) were added to 5 mL ultrapure water and a DLLME technique was applied. Several variables that govern the proposed technique were studied and optimized. Under optimum conditions, the method detection limits (MDLs) of PBDEs calculated as three times the signal-to-noise ratio (S/N) were within the range 0.02-0.06 ng g(-1). The relative standard deviations (RSDs) for five replicates were <9.8%. The calibration graphs were linear within the concentration range of 0.07-1000 ng g(-1) for BDE-47, 0.09-1000 ng g(-1) for BDE-100, 0.10-1000 ng g(-1) for BDE-99 and 0.19-1000 ng g(-1) for BDE-153 and the coefficients of estimation were > or =0.9991. Validation of the methodology was carried out by standard addition method at two concentration levels (0.25 and 1 ng g(-1)) and by comparing with a reference Soxhlet technique. Recovery values were > or =80%, which showed a satisfactory robustness of the analytical methodology for determination of low PBDEs concentration in sediment samples. Copyright 2010 Elsevier B.V. All rights reserved.

  15. Silicon micromachined waveguides for millimeter and submillimeter wavelengths

    NASA Technical Reports Server (NTRS)

    Yap, Markus; Tai, Yu-Chong; Mcgrath, William R.; Walker, Christopher

    1992-01-01

    The majority of radio receivers, transmitters, and components operating at millimeter and submillimeter wavelengths utilize rectangular waveguides in some form. However, conventional machining techniques for waveguides operating above a few hundred GHz are complicated and costly. This paper reports on the development of silicon micromachining techniques to create silicon-based waveguide circuits which can operate at millimeter and submillimeter wavelengths. As a first step, rectangular WR-10 waveguide structures have been fabricated from (110) silicon wafers using micromachining techniques. The waveguide is split along the broad wall. Each half is formed by first etching a channel completely through a wafer. Potassium hydroxide is used to etch smooth mirror-like vertical walls and LPCVD silicon nitride is used as a masking layer. This wafer is then bonded to another flat wafer using a polyimide bonding technique and diced into the U-shaped half wavelengths. Finally, a gold layer is applied to the waveguide walls. Insertion loss measurements show losses comparable to those of standard metal waveguides. It is suggested that active devices and planar circuits can be integrated with the waveguides, solving the traditional mounting problems. Potential applications in terahertz instrumentation technology are further discussed.

  16. Standard surface-reflectance model and illuminant estimation

    NASA Technical Reports Server (NTRS)

    Tominaga, Shoji; Wandell, Brian A.

    1989-01-01

    A vector analysis technique was adopted to test the standard reflectance model. A computational model was developed to determine the components of the observed spectra and an estimate of the illuminant was obtained without using a reference white standard. The accuracy of the standard model is evaluated.

  17. 76 FR 25376 - Occupational Exposure to Hazardous Chemicals in Laboratories Standard; Extension of the Office of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-04

    ... describes: Standard operating procedures for using hazardous chemicals; hazard-control techniques; equipment...] Occupational Exposure to Hazardous Chemicals in Laboratories Standard; Extension of the Office of Management... collection requirements specified in the Standard on Occupational Exposure to Hazardous Chemicals in...

  18. Blue dye for identification of sentinel nodes in breast cancer and malignant melanoma: a systematic review and meta-analysis.

    PubMed

    Peek, Mirjam Cl; Charalampoudis, Petros; Anninga, Bauke; Baker, Rose; Douek, Michael

    2017-02-01

    The combined technique (radioisotope and blue dye) is the gold standard for sentinel lymph node biopsy (SLNB) and there is wide variation in techniques and blue dyes used. We performed a systematic review and meta-analysis to assess the need for radioisotope and the optimal blue dye for SLNB. A total of 21 studies were included. The SLNB identification rates are high with all the commonly used blue dyes. Furthermore, methylene blue is superior to iso-sulfan blue and Patent Blue V with respect to false-negative rates. The combined technique remains the most accurate and effective technique for SLNB. In order to standardize the SLNB technique, comparative trials to determine the most effective blue dye and national guidelines are required.

  19. An alternative technique for orthotopic cardiac transplantation, with preservation of the normal anatomy of the right atrium.

    PubMed

    Sievers, H H; Weyand, M; Kraatz, E G; Bernhard, A

    1991-04-01

    The standard technique for orthotopic cardiac transplantation implies large atrial anastomoses which do not preserve the anatomical integrity of the donor atria. This may become a potential source of electrophysiological and mechanical atrial dysfunction, especially in the right atrium with the sinus node and the sensitive low-pressure atrioventricular valve. As an improvement we suggest an alternative technique which we have recently developed for orthotopic cardiac transplantation; it combines the simple, convenient left atrial connection of the standard technique with individual anastomoses of the superior and inferior venae cavae, preserving the right atrium of the donated heart intact. This technique and our first results in two cases are described. Postoperatively, no arrhythmias and no signs of tricuspid insufficiency were observed.

  20. Analysis of statistical and standard algorithms for detecting muscle onset with surface electromyography.

    PubMed

    Tenan, Matthew S; Tweedell, Andrew J; Haynes, Courtney A

    2017-01-01

    The timing of muscle activity is a commonly applied analytic method to understand how the nervous system controls movement. This study systematically evaluates six classes of standard and statistical algorithms to determine muscle onset in both experimental surface electromyography (EMG) and simulated EMG with a known onset time. Eighteen participants had EMG collected from the biceps brachii and vastus lateralis while performing a biceps curl or knee extension, respectively. Three established methods and three statistical methods for EMG onset were evaluated. Linear envelope, Teager-Kaiser energy operator + linear envelope and sample entropy were the established methods evaluated while general time series mean/variance, sequential and batch processing of parametric and nonparametric tools, and Bayesian changepoint analysis were the statistical techniques used. Visual EMG onset (experimental data) and objective EMG onset (simulated data) were compared with algorithmic EMG onset via root mean square error and linear regression models for stepwise elimination of inferior algorithms. The top algorithms for both data types were analyzed for their mean agreement with the gold standard onset and evaluation of 95% confidence intervals. The top algorithms were all Bayesian changepoint analysis iterations where the parameter of the prior (p0) was zero. The best performing Bayesian algorithms were p0 = 0 and a posterior probability for onset determination at 60-90%. While existing algorithms performed reasonably, the Bayesian changepoint analysis methodology provides greater reliability and accuracy when determining the singular onset of EMG activity in a time series. Further research is needed to determine if this class of algorithms perform equally well when the time series has multiple bursts of muscle activity.

  1. Standards of care and quality indicators for multidisciplinary care models for psoriatic arthritis in Spain.

    PubMed

    Gratacós, Jordi; Luelmo, Jesús; Rodríguez, Jesús; Notario, Jaume; Marco, Teresa Navío; de la Cueva, Pablo; Busquets, Manel Pujol; Font, Mercè García; Joven, Beatriz; Rivera, Raquel; Vega, Jose Luis Alvarez; Álvarez, Antonio Javier Chaves; Parera, Ricardo Sánchez; Carrascosa, Jose Carlos Ruiz; Martínez, Fernando José Rodríguez; Sánchez, José Pardo; Olmos, Carlos Feced; Pujol, Conrad; Galindez, Eva; Barrio, Silvia Pérez; Arana, Ana Urruticoechea; Hergueta, Mercedes; Coto, Pablo; Queiro, Rubén

    2018-06-01

    To define and give priority to standards of care and quality indicators of multidisciplinary care for patients with psoriatic arthritis (PsA). A systematic literature review on PsA standards of care and quality indicators was performed. An expert panel of rheumatologists and dermatologists who provide multidisciplinary care was established. In a consensus meeting group, the experts discussed and developed the standards of care and quality indicators and graded their priority, agreement and also the feasibility (only for quality indicators) following qualitative methodology and a Delphi process. Afterwards, these results were discussed with 2 focus groups, 1 with patients, another with health managers. A descriptive analysis is presented. We obtained 25 standards of care (9 of structure, 9 of process, 7 of results) and 24 quality indicators (2 of structure, 5 of process, 17 of results). Standards of care include relevant aspects in the multidisciplinary care of PsA patients like an appropriate physical infrastructure and technical equipment, the access to nursing care, labs and imaging techniques, other health professionals and treatments, or the development of care plans. Regarding quality indicators, the definition of multidisciplinary care model objectives and referral criteria, the establishment of responsibilities and coordination among professionals and the active evaluation of patients and data collection were given a high priority. Patients considered all of them as important. This set of standards of care and quality indicators for the multidisciplinary care of patients with PsA should help improve quality of care in these patients.

  2. In vitro interactions between splenocytes and dansylamide dye-embedded nanoparticles detected by flow cytometry

    PubMed Central

    Nyland, Jennifer F.; Bai, Jennifer J. K.; Katz, Howard E.; Silbergeld, Ellen K.

    2009-01-01

    Engineered nanoparticles (NPs) possess a range of biological activity. In vitro methods for assessing toxicity and efficacy would be enhanced by simultaneous quantitative information on the behavior of NPs in culture systems and signals of cell response. We have developed a method for visualizing NPs within cells using standard flow cytometric techniques and uniquely designed spherical siloxane NPs with an embedded (covalently bound) dansylamide dye. This method allowed NP visualization without obscuring detection of relevant biomarkers of cell subtype, activation state, and other events relevant to assessing bioactivity. We determined that NPs penetrated cells and induced a range of biological signals consistent with activation and costimulation. These results indicate that NPs may affect cell function at concentrations below those inducing cytotoxicity or apoptosis and demonstrate a novel method to image both localization of NPs and cell-level effects. PMID:19523425

  3. Heavy Ion Transient Characterization of a Photobit Hardened-by-Design Active Pixel Sensor Array

    NASA Technical Reports Server (NTRS)

    Marshall, Paul W.; Byers, Wheaton B.; Conger, Christopher; Eid, El-Sayed; Gee, George; Jones, Michael R.; Marshall, Cheryl J.; Reed, Robert; Pickel, Jim; Kniffin, Scott

    2002-01-01

    This paper presents heavy ion data on the single event transient (SET) response of a Photobit active pixel sensor (APS) four quadrant test chip with different radiation tolerant designs in a standard 0.35 micron CMOS process. The physical design techniques of enclosed geometry and P-channel guard rings are used to design the four N-type active photodiode pixels as described in a previous paper. Argon transient measurements on the 256 x 256 chip array as a function of incident angle show a significant variation in the amount of charge collected as well as the charge spreading dependent on the pixel type. The results are correlated with processing and design information provided by Photobit. In addition, there is a large degree of statistical variability between individual ion strikes. No latch-up is observed up to an LET of 106 MeV/mg/sq cm.

  4. Synthesis, characterization, antioxidant and brine shrimp cytotoxic activity of novel 3-benzothioyl-1-(3-hydroxy-3-phenyl -3-propyl)-1-methylthiourea.

    PubMed

    Shoaib, Mohammad; Ullah, Abid; Shah, Syed Wadood Ali; Tahir, Muhammad Nawaz

    2017-07-01

    In the present research work novel ephedrine based thiourea derivative, 3-benzothioyl-1-(3-hydroxy-3-phenyl -3-propyl)-1-methylthiourea 4is synthesized and then characterized elemental analyzed via various techniques i.e., Proton NMR, carbon13 NMR and fatherly confirmed via X-ray crystallography. Compound 4 was then screened for their possible antioxidant and cytotoxic potentials. Benzoyl chloride was treated with an equimolar potassium thiocyanate in acetone to achieve benzoyl isothiocyantes. It was then treated with an equimolar (1R, 2S)-(-)-Ephedrine to obtain the 3-benzothioyl-1-(3-hydroxy-3-phenyl-3-propyl)-1-methyl thiourea4. It was then screened for antioxidant and cytotoxic potentials. The compound 4 showed excellent antioxidant activity almost comparable to ascorbic acid (standard) and have significant cytotoxic activity with LC 50 value 05±0.58 ppm.

  5. Ebola Virus and Marburg Virus in Human Milk Are Inactivated by Holder Pasteurization.

    PubMed

    Hamilton Spence, Erin; Huff, Monica; Shattuck, Karen; Vickers, Amy; Yun, Nadezda; Paessler, Slobodan

    2017-05-01

    Potential donors of human milk are screened for Ebola virus (EBOV) using standard questions, but testing for EBOV and Marburg virus (MARV) is not part of routine serological testing performed by milk banks. Research aim: This study tested the hypothesis that EBOV would be inactivated in donor human milk (DHM) by standard pasteurization techniques (Holder) used in all North American nonprofit milk banks. Milk samples were obtained from a nonprofit milk bank. They were inoculated with EBOV (Zaire strain) and MARV (Angola strain) and processed by standard Holder pasteurization technique. Plaque assays for EBOV and MARV were performed to detect the presence of virus after pasteurization. Neither EBOV nor MARV was detectable by viral plaque assay in DHM or culture media samples, which were pasteurized by the Holder process. EBOV and MARV are safely inactivated in human milk by standard Holder pasteurization technique. Screening for EBOV or MARV beyond questionnaire and self-deferral is not needed to ensure safety of DHM for high-risk infants.

  6. Calcium Signaling in Intact Dorsal Root Ganglia

    PubMed Central

    Gemes, Geza; Rigaud, Marcel; Koopmeiners, Andrew S.; Poroli, Mark J.; Zoga, Vasiliki; Hogan, Quinn H.

    2013-01-01

    Background Ca2+ is the dominant second messenger in primary sensory neurons. In addition, disrupted Ca2+ signaling is a prominent feature in pain models involving peripheral nerve injury. Standard cytoplasmic Ca2+ recording techniques use high K+ or field stimulation and dissociated neurons. To compare findings in intact dorsal root ganglia, we used a method of simultaneous electrophysiologic and microfluorimetric recording. Methods Dissociated neurons were loaded by bath-applied Fura-2-AM and subjected to field stimulation. Alternatively, we adapted a technique in which neuronal somata of intact ganglia were loaded with Fura-2 through an intracellular microelectrode that provided simultaneous membrane potential recording during activation by action potentials (APs) conducted from attached dorsal roots. Results Field stimulation at levels necessary to activate neurons generated bath pH changes through electrolysis and failed to predictably drive neurons with AP trains. In the intact ganglion technique, single APs produced measurable Ca2+ transients that were fourfold larger in presumed nociceptive C-type neurons than in nonnociceptive Aβ-type neurons. Unitary Ca2+ transients summated during AP trains, forming transients with amplitudes that were highly dependent on stimulation frequency. Each neuron was tuned to a preferred frequency at which transient amplitude was maximal. Transients predominantly exhibited monoexponential recovery and had sustained plateaus during recovery only with trains of more than 100 APs. Nerve injury decreased Ca2+ transients in C-type neurons, but increased transients in Aβ-type neurons. Conclusions Refined observation of Ca2+ signaling is possible through natural activation by conducted APs in undissociated sensory neurons and reveals features distinct to neuronal types and injury state. PMID:20526180

  7. Cross-platform comparison of nucleic acid hybridization: toward quantitative reference standardsa

    PubMed Central

    Halvorsen, Ken; Agris, Paul F.

    2014-01-01

    Measuring interactions between biological molecules is vitally important to both basic and applied research, as well as development of pharmaceuticals. While a wide and growing range of techniques are available to measure various kinetic and thermodynamic properties of interacting biomolecules, it can be difficult to compare data across techniques of different laboratories and personnel, or even across different instruments using the same technique. Here we evaluate relevant biological interactions based on complementary DNA and RNA oligonucleotides that could be used as reference standards for many experimental systems. We measured thermodynamics of duplex formation using Isothermal Titration Calorimetry, Differential Scanning Calorimetry, and UV-Vis monitored denaturation/renaturation. These standards can be used to validate results, compare data from disparate techniques, act as a teaching tool for laboratory classes, or potentially to calibrate instruments. The RNA and DNA standards have many attractive features including low cost, high purity, easily measureable concentrations, and minimal handling concerns, making them ideal for use as a reference material. PMID:25124363

  8. Image-Based 3d Reconstruction and Analysis for Orthodontia

    NASA Astrophysics Data System (ADS)

    Knyaz, V. A.

    2012-08-01

    Among the main tasks of orthodontia are analysis of teeth arches and treatment planning for providing correct position for every tooth. The treatment plan is based on measurement of teeth parameters and designing perfect teeth arch curve which teeth are to create after treatment. The most common technique for teeth moving uses standard brackets which put on teeth and a wire of given shape which is clamped by these brackets for producing necessary forces to every tooth for moving it in given direction. The disadvantages of standard bracket technique are low accuracy of tooth dimensions measurements and problems with applying standard approach for wide variety of complex orthodontic cases. The image-based technique for orthodontic planning, treatment and documenting aimed at overcoming these disadvantages is proposed. The proposed approach provides performing accurate measurements of teeth parameters needed for adequate planning, designing correct teeth position and monitoring treatment process. The developed technique applies photogrammetric means for teeth arch 3D model generation, brackets position determination and teeth shifting analysis.

  9. Clinical-grade mesenchymal stromal cells produced under various good manufacturing practice processes differ in their immunomodulatory properties: standardization of immune quality controls.

    PubMed

    Menard, Cedric; Pacelli, Luciano; Bassi, Giulio; Dulong, Joelle; Bifari, Francesco; Bezier, Isabelle; Zanoncello, Jasmina; Ricciardi, Mario; Latour, Maelle; Bourin, Philippe; Schrezenmeier, Hubert; Sensebé, Luc; Tarte, Karin; Krampera, Mauro

    2013-06-15

    Clinical-grade mesenchymal stromal cells (MSCs) are usually expanded from bone marrow (BMMSCs) or adipose tissue (ADSCs) using processes mainly differing in the use of fetal calf serum (FCS) or human platelet lysate (PL). We aimed to compare immune modulatory properties of clinical-grade MSCs using a combination of fully standardized in vitro assays. BMMSCs expanded with FCS (BMMSC-FCS) or PL (BMMSC-PL), and ADSC-PL were analyzed in quantitative phenotypic and functional experiments, including their capacity to inhibit the proliferation of T, B, and NK cells. The molecular mechanisms supporting T-cell inhibition were investigated. These parameters were also evaluated after pre-stimulation of MSCs with inflammatory cytokines. BMMSC-FCS, BMMSC-PL, and ADSC-PL displayed significant differences in expression of immunosuppressive and adhesion molecules. Standardized functional assays revealed that resting MSCs inhibited proliferation of T and NK cells, but not B cells. ADSC-PL were the most potent in inhibiting T-cell growth, a property ascribed to interferon-γ-dependent indoleamine 2,3-dioxygenase activity. MSCs did not stimulate allogeneic T cell proliferation but were efficiently lysed by activated NK cells. The systematic use of quantitative and reproducible validation techniques highlights differences in immunological properties of MSCs produced using various clinical-grade processes. ADSC-PL emerge as a promising candidate for future clinical trials.

  10. Clinical-Grade Mesenchymal Stromal Cells Produced Under Various Good Manufacturing Practice Processes Differ in Their Immunomodulatory Properties: Standardization of Immune Quality Controls

    PubMed Central

    Menard, Cedric; Pacelli, Luciano; Bassi, Giulio; Dulong, Joelle; Bifari, Francesco; Bezier, Isabelle; Zanoncello, Jasmina; Ricciardi, Mario; Latour, Maelle; Bourin, Philippe; Schrezenmeier, Hubert; Sensebé, Luc

    2013-01-01

    Clinical-grade mesenchymal stromal cells (MSCs) are usually expanded from bone marrow (BMMSCs) or adipose tissue (ADSCs) using processes mainly differing in the use of fetal calf serum (FCS) or human platelet lysate (PL). We aimed to compare immune modulatory properties of clinical-grade MSCs using a combination of fully standardized in vitro assays. BMMSCs expanded with FCS (BMMSC-FCS) or PL (BMMSC-PL), and ADSC-PL were analyzed in quantitative phenotypic and functional experiments, including their capacity to inhibit the proliferation of T, B, and NK cells. The molecular mechanisms supporting T-cell inhibition were investigated. These parameters were also evaluated after pre-stimulation of MSCs with inflammatory cytokines. BMMSC-FCS, BMMSC-PL, and ADSC-PL displayed significant differences in expression of immunosuppressive and adhesion molecules. Standardized functional assays revealed that resting MSCs inhibited proliferation of T and NK cells, but not B cells. ADSC-PL were the most potent in inhibiting T-cell growth, a property ascribed to interferon-γ-dependent indoleamine 2,3-dioxygenase activity. MSCs did not stimulate allogeneic T cell proliferation but were efficiently lysed by activated NK cells. The systematic use of quantitative and reproducible validation techniques highlights differences in immunological properties of MSCs produced using various clinical-grade processes. ADSC-PL emerge as a promising candidate for future clinical trials. PMID:23339531

  11. Integrating Map Algebra and Statistical Modeling for Spatio- Temporal Analysis of Monthly Mean Daily Incident Photosynthetically Active Radiation (PAR) over a Complex Terrain.

    PubMed

    Evrendilek, Fatih

    2007-12-12

    This study aims at quantifying spatio-temporal dynamics of monthly mean dailyincident photosynthetically active radiation (PAR) over a vast and complex terrain such asTurkey. The spatial interpolation method of universal kriging, and the combination ofmultiple linear regression (MLR) models and map algebra techniques were implemented togenerate surface maps of PAR with a grid resolution of 500 x 500 m as a function of fivegeographical and 14 climatic variables. Performance of the geostatistical and MLR modelswas compared using mean prediction error (MPE), root-mean-square prediction error(RMSPE), average standard prediction error (ASE), mean standardized prediction error(MSPE), root-mean-square standardized prediction error (RMSSPE), and adjustedcoefficient of determination (R² adj. ). The best-fit MLR- and universal kriging-generatedmodels of monthly mean daily PAR were validated against an independent 37-year observeddataset of 35 climate stations derived from 160 stations across Turkey by the Jackknifingmethod. The spatial variability patterns of monthly mean daily incident PAR were moreaccurately reflected in the surface maps created by the MLR-based models than in thosecreated by the universal kriging method, in particular, for spring (May) and autumn(November). The MLR-based spatial interpolation algorithms of PAR described in thisstudy indicated the significance of the multifactor approach to understanding and mappingspatio-temporal dynamics of PAR for a complex terrain over meso-scales.

  12. Bacteriological quality and risk assessment of the imported and domestic bottled mineral water sold in Fiji.

    PubMed

    Zeenat, A; Hatha, A A M; Viola, L; Vipra, K

    2009-12-01

    Considering the popularity of bottled mineral water among indigenous Fijians and tourists alike, a study was carried out to determine the bacteriological quality of different bottled waters. A risk assessment was also carried out. Seventy-five samples of bottled mineral water belonging to three domestic brands and 25 samples of one imported brand were analysed for heterotrophic plate count (HPC) bacteria and faecal coliforms. HPC counts were determined at 22 degrees C and 37 degrees C using R2A medium and a membrane filtration technique was used to determine the faecal coliform (FC) load in 100 ml of water on mFC agar. Between 28 and 68% of the samples of the various domestic brands failed to meet the WHO standard of 100 colony forming units (cfu) per 100 ml at 22 degrees C and 7% of these also tested positive for faecal coliforms. All imported bottled mineral water samples were within WHO standards. A risk assessment of the HPC bacteria was carried out in terms of beta haemolytic activity and antibiotic resistance. More than 50% of the isolates showed beta haemolytic activity and were multi-drug resistant. While the overall quality of the product was generally good, there is a need to enforce stringent quality standards for the domestic bottlers to ensure the safety of consumers.

  13. Dose to the contralateral breast: a comparison of two techniques using the enhanced dynamic wedge versus a standard wedge.

    PubMed

    Warlick, W B; O'Rear, J H; Earley, L; Moeller, J H; Gaffney, D K; Leavitt, D D

    1997-01-01

    The dose to the contralateral breast has been associated with an increased risk of developing a second breast malignancy. Varying techniques have been devised and described in the literature to minimize this dose. Metal beam modifiers such as standard wedges are used to improve the dose distribution in the treated breast, but unfortunately introduce an increased scatter dose outside the treatment field, in particular to the contralateral breast. The enhanced dynamic wedge is a means of remote wedging created by independently moving one collimator jaw through the treatment field during dose delivery. This study is an analysis of differing doses to the contralateral breast using two common clinical set-up techniques with the enhanced dynamic wedge versus the standard metal wedge. A tissue equivalent block (solid water), modeled to represent a typical breast outline, was designed as an insert in a Rando phantom to simulate a standard patient being treated for breast conservation. Tissue equivalent material was then used to complete the natural contour of the breast and to reproduce appropriate build-up and internal scatter. Thermoluminescent dosimeter (TLD) rods were placed at predetermined distances from the geometric beam's edge to measure the dose to the contralateral breast. A total of 35 locations were used with five TLDs in each location to verify the accuracy of the measured dose. The radiation techniques used were an isocentric set-up with co-planar, non divergent posterior borders and an isocentric set-up with a half beam block technique utilizing the asymmetric collimator jaw. Each technique used compensating wedges to optimize the dose distribution. A comparison of the dose to the contralateral breast was then made with the enhanced dynamic wedge vs. the standard metal wedge. The measurements revealed a significant reduction in the contralateral breast dose with the enhanced dynamic wedge compared to the standard metal wedge in both set-up techniques. The dose was measured at varying distances from the geometric field edge, ranging from 2 to 8 cm. The average dose with the enhanced dynamic wedge was 2.7-2.8%. The average dose with the standard wedge was 4.0-4.7%. Thermoluminescent dosimeter measurements suggest an increase in both scattered electrons and photons with metal wedges. The enhanced dynamic wedge is a practical clinical advance which improves the dose distribution in patients undergoing breast conservation while at the same time minimizing dose to the contralateral breast, thereby reducing the potential carcinogenic effects.

  14. Direct magnitude estimates of speech intelligibility in dysarthria: effects of a chosen standard.

    PubMed

    Weismer, Gary; Laures, Jacqueline S

    2002-06-01

    Direct magnitude estimation (DME) has been used frequently as a perceptual scaling technique in studies of the speech intelligibility of persons with speech disorders. The technique is typically used with a standard, or reference stimulus, chosen as a good exemplar of "midrange" intelligibility. In several published studies, the standard has been chosen subjectively, usually on the basis of the expertise of the investigators. The current experiment demonstrates that a fixed set of sentence-level utterances, obtained from 4 individuals with dysarthria (2 with Parkinson disease, 2 with traumatic brain injury) as well as 3 neurologically normal speakers, is scaled differently depending on the identity of the standard. Four different standards were used in the main experiment, three of which were judged qualitatively in two independent evaluations to be good exemplars of midrange intelligibility. Acoustic analyses did not reveal obvious differences between these four standards but suggested that the standard with the worst-scaled intelligibility had much poorer voice source characteristics compared to the other three standards. Results are discussed in terms of possible standardization of midrange intelligibility exemplars for DME experiments.

  15. Reliability and Validity of 10 Different Standard Setting Procedures.

    ERIC Educational Resources Information Center

    Halpin, Glennelle; Halpin, Gerald

    Research indicating that different cut-off points result from the use of different standard-setting techniques leaves decision makers with a disturbing dilemma: Which standard-setting method is best? This investigation of the reliability and validity of 10 different standard-setting approaches was designed to provide information that might help…

  16. Epidural technique for postoperative pain: gold standard no more?

    PubMed

    Rawal, Narinder

    2012-01-01

    Epidural analgesia is a well-established technique that has commonly been regarded as the gold standard in postoperative pain management. However, newer, evidence-based outcome data show that the benefits of epidural analgesia are not as significant as previously believed. There are some benefits in a decrease in the incidence of cardiovascular and pulmonary complications, but these benefits are probably limited to high-risk patients undergoing major abdominal or thoracic surgery who receive thoracic epidural analgesia with local anaesthetic drugs only. There is increasing evidence that less invasive regional analgesic techniques are as effective as epidural analgesia. These include paravertebral block for thoracotomy, femoral block for total hip and knee arthroplasty, wound catheter infusions for cesarean delivery, and local infiltration analgesia techniques for lower limb joint arthroplasty. Wound infiltration techniques and their modifications are simple and safe alternatives for a variety of other surgical procedures. Although pain relief associated with epidural analgesia can be outstanding, clinicians expect more from this invasive, high-cost, labour-intensive technique. The number of indications for the use of epidural analgesia seems to be decreasing for a variety of reasons. The decision about whether to continue using epidural techniques should be guided by regular institutional audits and careful risk-benefit assessment rather than by tradition. For routine postoperative analgesia, epidural analgesia may no longer be considered the gold standard.

  17. [Determination of acetanilide herbicide residues in tea by gas chromatography-mass spectrometry with two different ionization techniques].

    PubMed

    Shen, Weijian; Xu, Jinzhong; Yang, Wenquan; Shen, Chongyu; Zhao, Zengyun; Ding, Tao; Wu, Bin

    2007-09-01

    An analytical method of solid phase extraction-gas chromatography-mass spectrometry with two different ionization techniques was established for simultaneous determination of 12 acetanilide herbicide residues in tea-leaves. Herbicides were extracted from tea-leaf samples with ethyl acetate. The extract was cleaned-up on an active carbon SPE column connected to a Florisil SPE column. Analytical screening was determined by the technique of gas chromatography (GC)-mass spectrometry (MS) in the selected ion monitoring (SIM) mode with either electron impact ionization (EI) or negative chemical ionization (NCI). It is reliable and stable that the recoveries of all herbicides were in the range from 50% to 110% at three spiked levels, 10 microg/kg, 20 microg/kg and 40 microg/kg, and the relative standard deviations (RSDs) were no more than 10.9%. The two different ionization techniques are complementary as more ion fragmentation information can be obtained from the EI mode while more molecular ion information from the NCI mode. By comparison of the two techniques, the selectivity of NCI-SIM was much better than that of EI-SIM method. The sensitivities of the both techniques were high, the limit of quantitative (LOQ) for each herbicide was no more than 2.0 microg/kg, and the limit of detection (LOD) with NCI-SIM technique was much lower than that of EI-SIM when analyzing herbicides with several halogen atoms in the molecule.

  18. In situ health monitoring for bogie systems of CRH380 train on Beijing-Shanghai high-speed railway

    NASA Astrophysics Data System (ADS)

    Hong, Ming; Wang, Qiang; Su, Zhongqing; Cheng, Li

    2014-04-01

    Based on the authors' research efforts over the years, an in situ structural health monitoring (SHM) technique taking advantage of guided elastic waves has been developed and deployed via an online diagnosis system. The technique and the system were recently implemented on China's latest high-speed train (CRH380CL) operated on Beijing-Shanghai High-Speed Railway. The system incorporated modularized components including active sensor network, active wave generation, multi-channel data acquisition, signal processing, data fusion, and results presentation. The sensor network, inspired by a new concept—"decentralized standard sensing", was integrated into the bogie frames during the final assembly of CRH380CL, to generate and acquire bogie-guided ultrasonic waves, from which a wide array of signal features were extracted. Fusion of signal features through a diagnostic imaging algorithm led to a graphic illustration of the overall health state of the bogie in a real-time and intuitive manner. The in situ experimentation covered a variety of high-speed train operation events including startup, acceleration/deceleration, full-speed operation (300 km/h), emergency braking, track change, as well as full stop. Mock-up damage affixed to the bogie was identified quantitatively and visualized in images. This in situ testing has demonstrated the feasibility, effectiveness, sensitivity, and reliability of the developed SHM technique and the system towards real-world applications.

  19. MEG-SIM: a web portal for testing MEG analysis methods using realistic simulated and empirical data.

    PubMed

    Aine, C J; Sanfratello, L; Ranken, D; Best, E; MacArthur, J A; Wallace, T; Gilliam, K; Donahue, C H; Montaño, R; Bryant, J E; Scott, A; Stephen, J M

    2012-04-01

    MEG and EEG measure electrophysiological activity in the brain with exquisite temporal resolution. Because of this unique strength relative to noninvasive hemodynamic-based measures (fMRI, PET), the complementary nature of hemodynamic and electrophysiological techniques is becoming more widely recognized (e.g., Human Connectome Project). However, the available analysis methods for solving the inverse problem for MEG and EEG have not been compared and standardized to the extent that they have for fMRI/PET. A number of factors, including the non-uniqueness of the solution to the inverse problem for MEG/EEG, have led to multiple analysis techniques which have not been tested on consistent datasets, making direct comparisons of techniques challenging (or impossible). Since each of the methods is known to have their own set of strengths and weaknesses, it would be beneficial to quantify them. Toward this end, we are announcing the establishment of a website containing an extensive series of realistic simulated data for testing purposes ( http://cobre.mrn.org/megsim/ ). Here, we present: 1) a brief overview of the basic types of inverse procedures; 2) the rationale and description of the testbed created; and 3) cases emphasizing functional connectivity (e.g., oscillatory activity) suitable for a wide assortment of analyses including independent component analysis (ICA), Granger Causality/Directed transfer function, and single-trial analysis.

  20. MEG-SIM: A Web Portal for Testing MEG Analysis Methods using Realistic Simulated and Empirical Data

    PubMed Central

    Aine, C. J.; Sanfratello, L.; Ranken, D.; Best, E.; MacArthur, J. A.; Wallace, T.; Gilliam, K.; Donahue, C. H.; Montaño, R.; Bryant, J. E.; Scott, A.; Stephen, J. M.

    2012-01-01

    MEG and EEG measure electrophysiological activity in the brain with exquisite temporal resolution. Because of this unique strength relative to noninvasive hemodynamic-based measures (fMRI, PET), the complementary nature of hemodynamic and electrophysiological techniques is becoming more widely recognized (e.g., Human Connectome Project). However, the available analysis methods for solving the inverse problem for MEG and EEG have not been compared and standardized to the extent that they have for fMRI/PET. A number of factors, including the non-uniqueness of the solution to the inverse problem for MEG/EEG, have led to multiple analysis techniques which have not been tested on consistent datasets, making direct comparisons of techniques challenging (or impossible). Since each of the methods is known to have their own set of strengths and weaknesses, it would be beneficial to quantify them. Toward this end, we are announcing the establishment of a website containing an extensive series of realistic simulated data for testing purposes (http://cobre.mrn.org/megsim/). Here, we present: 1) a brief overview of the basic types of inverse procedures; 2) the rationale and description of the testbed created; and 3) cases emphasizing functional connectivity (e.g., oscillatory activity) suitable for a wide assortment of analyses including independent component analysis (ICA), Granger Causality/Directed transfer function, and single-trial analysis. PMID:22068921

Top