Sample records for tendon structural characteristics

  1. Structural and biomechanical characteristics after early mobilization in an Achilles tendon rupture model: operative versus nonoperative treatment.

    PubMed

    Krapf, Daniel; Kaipel, Martin; Majewski, Martin

    2012-09-01

    Acute Achilles tendon ruptures are common sports injuries; however, treatment remains a clinical challenge. Studies show a superior effect of early mobilization and full weight bearing on tendon healing and clinical outcome; however, few data exist on structural and biomechanical characteristics in the early healing phase. This study investigated the histological and biomechanical characteristics of early mobilization and full weight bearing in an Achilles tendon rupture model. Eighty rats underwent dissection of a hindpaw Achilles tendon; 40 rats were treated conservatively and 40 underwent open repair of the transected Achilles tendon by suturing. Early mobilization and full weight bearing were allowed in both groups. At 1, 2, 4, and 8 weeks after tenotomy, tensile strength, stiffness, thickness, tissue characteristics (histological analysis), and length were determined. Dissected Achilles tendons healed in all animals during full weight-bearing early mobilization. One and 2 weeks after tenotomy, rats in the operative group showed increased tensile strength and stiffness compared with the nonoperative group. Repair-site diameters were increased at 1, 2, and 8 weeks after tenotomy. Tendon length was decreased in the operative group throughout observation, whereas the nonoperative group showed increased structural characteristics on the cellular level and a more homogeneous collagen distribution. Surgical treatment of dissected rat Achilles tendons showed superior biomechanical characteristics within the first 2 weeks. Conservative treatment resulted in superior histological findings but significant lengthening of the tendon in the early healing phase (weeks 1-8). Copyright 2012, SLACK Incorporated.

  2. Tendon biomechanics and mechanobiology - a mini-review of basic concepts and recent advancements

    PubMed Central

    Wang, James H-C.; Guo, Qianping; Li, Bin

    2011-01-01

    Due to their unique hierarchical structure and composition, tendons possess characteristic biomechanical properties, including high mechanical strength and viscoelasticity, which enable them to carry and transmit mechanical loads (muscular forces) effectively. Tendons are also mechano-responsive by adaptively changing their structure and function in response to altered mechanical loading conditions. In general, mechanical loading at physiological levels is beneficial to tendons, but excessive loading or disuse of tendons is detrimental. This mechano-adaptability is due to the cells present in tendons. Tendon fibroblasts (tenocytes) are the dominant tendon cells responsible for tendon homeostasis and repair. Tendon stem cells (TSCs), which were recently discovered, also play a vital role in tendon maintenance and repair by virtue of their ability to self-renew and differentiate into tenocytes. TSCs may also be responsible for chronic tendon injury, or tendinopathy, by undergoing aberrant differentiation into non-tenocytes in response to excessive mechanical loading. Thus, it is necessary to devise optimal rehabilitation protocols in order to enhance tendon healing while reducing scar tissue formation and tendon adhesions. Moreover, along with scaffolds that can mimic tendon matrix environments and platelet-rich plasma (PRP), which serves as a source of growth factors, TSCs may be the optimal cell type for enhancing repair of injured tendons. PMID:21925835

  3. Tendon biomechanics and mechanobiology--a minireview of basic concepts and recent advancements.

    PubMed

    Wang, James H-C; Guo, Qianping; Li, Bin

    2012-01-01

    Due to their unique hierarchical structure and composition, tendons possess characteristic biomechanical properties, including high mechanical strength and viscoelasticity, which enable them to carry and transmit mechanical loads (muscular forces) effectively. Tendons are also mechanoresponsive by adaptively changing their structure and function in response to altered mechanical loading conditions. In general, mechanical loading at physiological levels is beneficial to tendons, but excessive loading or disuse of tendons is detrimental. This mechanoadaptability is due to the cells present in tendons. Tendon fibroblasts (tenocytes) are the dominant tendon cells responsible for tendon homeostasis and repair. Tendon stem cells (TSCs), which were recently discovered, also play a vital role in tendon maintenance and repair by virtue of their ability to self-renew and differentiate into tenocytes. TSCs may also be responsible for chronic tendon injury, or tendinopathy, by undergoing aberrant differentiation into nontenocytes in response to excessive mechanical loading. Thus, it is necessary to devise optimal rehabilitation protocols to enhance tendon healing while reducing scar tissue formation and tendon adhesions. Moreover, along with scaffolds that can mimic tendon matrix environments and platelet-rich plasma, which serves as a source of growth factors, TSCs may be the optimal cell type for enhancing repair of injured tendons. Copyright © 2012 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  4. Tendon and ligament imaging

    PubMed Central

    Hodgson, R J; O'Connor, P J; Grainger, A J

    2012-01-01

    MRI and ultrasound are now widely used for the assessment of tendon and ligament abnormalities. Healthy tendons and ligaments contain high levels of collagen with a structured orientation, which gives rise to their characteristic normal imaging appearances as well as causing particular imaging artefacts. Changes to ligaments and tendons as a result of disease and injury can be demonstrated using both ultrasound and MRI. These have been validated against surgical and histological findings. Novel imaging techniques are being developed that may improve the ability of MRI and ultrasound to assess tendon and ligament disease. PMID:22553301

  5. Ultrasound Characteristics of the Achilles Tendon in Tophaceous Gout: A Comparison with Age- and Sex-matched Controls.

    PubMed

    Carroll, Matthew; Dalbeth, Nicola; Allen, Bruce; Stewart, Sarah; House, Tony; Boocock, Mark; Frampton, Christopher; Rome, Keith

    2017-10-01

    To investigate the frequency and distribution of characteristics of the Achilles tendon (AT) in people with tophaceous gout using musculoskeletal ultrasound (US). Twenty-four participants with tophaceous gout and 24 age- and sex-matched controls without gout or other arthritis were recruited. All participants underwent a greyscale and power Doppler US examination. The AT was divided into 3 anatomical zones (insertion, pre-insertional, and proximal to the mid-section). The following US characteristics were assessed: tophus, tendon echogenicity, tendon vascularity, tendon morphology, entheseal characteristics, bursal morphology, and calcaneal bone profile. The majority of the participants with tophaceous gout were middle-aged men (n = 22, 92%) predominately of European ethnicity (n = 14, 58%). Tophus deposition was observed in 73% (n = 35) of tendons in those with gout and in none of the controls (p < 0.01). Intratendinous hyperechoic spots (p < 0.01) and intratendinous power Doppler signal (p < 0.01) were more frequent in participants with gout compared to controls. High prevalence of entheseal calcifications, calcaneal bone cortex irregularities, and calcaneal enthesophytes were observed in both gout participants and controls, without differences between groups. Intratendinous structural damage was rare. Hyperechoic spots were significantly more common at the insertion compared to the zone proximal to the mid-section (p < 0.01), but between-zone differences were not observed for other features. US features of urate deposition, tophus, and vascularization are present throughout the AT in patients with tophaceous gout. Despite crystal deposition, intratendinous structural changes are infrequent. Many characteristics observed in the AT in people with tophaceous gout, particularly at the calcaneal enthesis, are not disease-specific.

  6. Experimental evaluation of multiscale tendon mechanics.

    PubMed

    Fang, Fei; Lake, Spencer P

    2017-07-01

    Tendon's primary function is a mechanical link between muscle and bone. The hierarchical structure of tendon and specific compositional constituents are believed to be critical for proper mechanical function. With increased appreciation for tendon importance and the development of various technological advances, this review paper summarizes recent experimental approaches that have been used to study multiscale tendon mechanics, includes an overview of studies that have evaluated the role of specific tissue constituents, and also proposes challenges/opportunities facing tendon study. Tendon has been demonstrated to have specific structural characteristics (e.g., multi-level hierarchy, crimp pattern, helix) and complex mechanical properties (e.g., non-linearity, anisotropy, viscoelasticity). Physical mechanisms including uncrimping, fiber sliding, and collagen reorganization have been shown to govern tendon mechanical responses under both static and dynamic loading. Several tendon constituents with relatively small quantities have been suggested to play a role in its mechanics, although some results are conflicting. Further research should be performed to understand the interplay and communication of tendon mechanical properties across levels of the hierarchical structure, and further show how each of these components contribute to tendon mechanics. The studies summarized and discussed in this review have helped elucidate important aspects of multiscale tendon mechanics, which is a prerequisite for analyzing stress/strain transfer between multiple scales and identifying key principles of mechanotransduction. This information could further facilitate interpreting the functional diversity of tendons from different species, different locations, and even different developmental stages, and then better understand and identify fundamental concepts related to tendon degeneration, disease, and healing. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1353-1365, 2017. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  7. A passive exoskeleton with artificial tendons: design and experimental evaluation.

    PubMed

    van Dijk, Wietse; van der Kooij, Herman; Hekman, Edsko

    2011-01-01

    We developed a passive exoskeleton that was designed to minimize joint work during walking. The exoskeleton makes use of passive structures, called artificial tendons, acting in parallel with the leg. Artificial tendons are elastic elements that are able to store and redistribute energy over the human leg joints. The elastic characteristics of the tendons have been optimized to minimize the mechanical work of the human leg joints. In simulation the maximal reduction was 40 percent. The performance of the exoskeleton was evaluated in an experiment in which nine subjects participated. Energy expenditure and muscle activation were measured during three conditions: Normal walking, walking with the exoskeleton without artificial tendons, and walking with the exoskeleton with the artificial tendons. Normal walking was the most energy efficient. While walking with the exoskeleton, the artificial tendons only resulted in a negligibly small decrease in energy expenditure. © 2011 IEEE

  8. Tendon exhibits complex poroelastic behavior at the nanoscale as revealed by high-frequency AFM-based rheology.

    PubMed

    Connizzo, Brianne K; Grodzinsky, Alan J

    2017-03-21

    Tendons transmit load from muscle to bone by utilizing their unique static and viscoelastic tensile properties. These properties are highly dependent on the composition and structure of the tissue matrix, including the collagen I hierarchy, proteoglycans, and water. While the role of matrix constituents in the tensile response has been studied, their role in compression, particularly in matrix pressurization via regulation of fluid flow, is not well understood. Injured or diseased tendons and tendon regions that naturally experience compression are known to have alterations in glycosaminoglycan content, which could modulate fluid flow and ultimately mechanical function. While recent theoretical studies have predicted tendon mechanics using poroelastic theory, no experimental data have directly demonstrated such behavior. In this study, we use high-bandwidth AFM-based rheology to determine the dynamic response of tendons to compressive loading at the nanoscale and to determine the presence of poroelastic behavior. Tendons are found to have significant characteristic dynamic relaxation behavior occurring at both low and high frequencies. Classic poroelastic behavior is observed, although we hypothesize that the full dynamic response is caused by a combination of flow-dependent poroelasticity as well as flow-independent viscoelasticity. Tendons also demonstrate regional dependence in their dynamic response, particularly near the junction of tendon and bone, suggesting that the structural and compositional heterogeneity in tendon may be responsible for regional poroelastic behavior. Overall, these experiments provide the foundation for understanding fluid-flow-dependent poroelastic mechanics of tendon, and the methodology is valuable for assessing changes in tendon matrix compressive behavior at the nanoscale. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Fibrocartilage associated with human tendons and their pulleys.

    PubMed Central

    Benjamin, M; Qin, S; Ralphs, J R

    1995-01-01

    The presence of fibrocartilage in tendons that wrap around bony or fibrous pulleys is well known. It is an adaptation to resisting compression or shear, but the extent to which the structure of most human tendons is modified where they contact pulleys is less clear, for there has been no single comprehensive survey of a large number of sites. Less is known of the structure of the corresponding pulleys. In the present study, 38 regions of tendons that wrap around bony pulleys or pass beneath fibrous retinacula have been studied in routine histology sections taken from each of 2 or 3 elderly dissecting room cadavers. Most of the corresponding pulleys have also been examined. Fibrocartilage was present in 22 of the 38 tendon sites and it was most conspicuous where the tendons pressed predominantly against bone rather than retinacula and where they showed a large change in direction. Fibrocartilage was more characteristic of tendons at the ankle than the wrist, probably because the long axis of the foot is at right angles to that of the leg. There was considerable variation in the structure of tendon fibrocartilage. The most fibrocartilaginous tendons had oval or round cells embedded in a highly metachromatic matrix with interwoven or spiralling collagen fibres. At other sites, fibrocartilage cells were arranged in rows between parallel collagen fibres. The differences probably relate to differences in development. A single tendon could be modified at successive points along its length and fibrocartilage could be present in the endotenon and epitenon as well as in the tendon itself. Pathological changes seen in 'wrap around' tendons were fragmentation and partial delamination of the compressed surface, chondrocyte clustering, fatty infiltration and bone formation. Three types of pulleys were described for tendons--bony prominences and grooves, fibrous retinacula and synovial joints. The extent of cartilaginous differentiation on the periosteum of bony pulleys frequently mirrored that in the corresponding tendon. The cartilage or fibrocartilage prevents the tendon from 'sawing' through the bone. Some of the best known retinacula were largely fibrous, though the inferior peroneal retinaculum and the trochlea for the superior oblique were cartilaginous. The results underline the considerable regional heterogeneity in different tendons and their pulleys. They show that one tendon is not like another and that tendons may need to be carefully selected for particular surgical transfers or joint reconstructions. Images Fig. 1 Figs 2-3 Fig. 4 Fig. 5 Fig. 6 Fig. 7 Fig. 8 Fig. 9 Fig. 11 Fig. 12 Fig. 13 Fig. 14 Fig. 15 Fig. 16 Fig. 17 Fig. 18 PMID:8586561

  10. Characterization via atomic force microscopy of discrete plasticity in collagen fibrils from mechanically overloaded tendons: Nano-scale structural changes mimic rope failure.

    PubMed

    Baldwin, Samuel J; Kreplak, Laurent; Lee, J Michael

    2016-07-01

    Tendons exposed to tensile overload show a structural alteration at the fibril scale termed discrete plasticity. Serial kinks appear along individual collagen fibrils that are susceptible to enzymatic digestion and are thermally unstable. Using atomic force microscopy we mapped the topography and mechanical properties in dehydrated and hydrated states of 25 control fibrils and 25 fibrils displaying periodic kinks, extracted from overloaded bovine tail tendons. Using the measured modulus of the hydrated fibrils as a probe of molecular density, we observed a non-linear negative correlation between molecular density and kink density of individual fibrils. This is accompanied by an increase in water uptake with kink density and a doubling of the coefficient of variation of the modulus between kinked, and control fibrils. The mechanical property maps of kinked collagen fibrils show radial heterogeneity that can be modeled as a high-density core surrounded by a low-density shell. The core of the fibril contains the kink structures characteristic of discrete plasticity; separated by inter-kink regions, which often retain the D-banding structure. We propose that the shell and kink structures mimic characteristic damage motifs observed in laid rope strands. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Multiscale Poly-(ϵ-caprolactone) Scaffold Mimicking Nonlinearity in Tendon Tissue Mechanics

    PubMed Central

    Banik, Brittany L.; Lewis, Gregory S.; Brown, Justin L.

    2016-01-01

    Regenerative medicine plays a critical role in the future of medicine. However, challenges remain to balance stem cells, biomaterial scaffolds, and biochemical factors to create successful and effective scaffold designs. This project analyzes scaffold architecture with respect to mechanical capability and preliminary mesenchymal stem cell response for tendon regeneration. An electrospun fiber scaffold with tailorable properties based on a “Chinese-fingertrap” design is presented. The unique criss-crossed fiber structures demonstrate non-linear mechanical response similar to that observed in native tendon. Mechanical testing revealed that optimizing the fiber orientation resulted in the characteristic “S”-shaped curve, demonstrating a toe region and linear elastic region. This project has promising research potential across various disciplines: vascular engineering, nerve regeneration, and ligament and tendon tissue engineering. PMID:27141530

  12. Decorin expression is important for age-related changes in tendon structure and mechanical properties

    PubMed Central

    Dunkman, Andrew A.; Buckley, Mark R.; Mienaltowski, Michael J.; Adams, Sheila M.; Thomas, Stephen J.; Satchell, Lauren; Kumar, Akash; Pathmanathan, Lydia; Beason, David P.; Iozzo, Renato V.; Birk, David E.; Soslowsky, Louis J.

    2013-01-01

    The aging population is at an increased risk of tendon injury and tendinopathy. Elucidating the molecular basis of tendon aging is crucial to understanding the age-related changes in structure and function in this vulnerable tissue. In this study, the structural and functional features of tendon aging are investigated. In addition, the roles of decorin and biglycan in the aging process were analyzed using transgenic mice at both mature and aged time points. Our hypothesis is that the increase in tendon injuries in the aging population is the result of altered structural properties that reduce the biomechanical function of the tendon and consequently increase susceptibility to injury. Decorin and biglycan are important regulators of tendon structure and therefore, we further hypothesized that decreased function in aged tendons is partly the result of altered decorin and biglycan expression. Biomechanical analyses of mature (day 150) and aged (day 570) patellar tendons revealed deteriorating viscoelastic properties with age. Histology and polarized light microscopy demonstrated decreased cellularity, alterations in tenocyte shape, and reduced collagen fiber alignment in the aged tendons. Ultrastructural analysis of fibril diameter distributions indicated an altered distribution in aged tendons with an increase of large diameter fibrils. Aged wild type tendons maintained expression of decorin which was associated with the structural and functional changes seen in aged tendons. Aged patellar tendons exhibited altered and generally inferior properties across multiple assays. However, decorin-null tendons exhibited significantly decreased effects of aging compared to the other genotypes. The amelioration of the functional deficits seen in the absence of decorin in aged tendons was associated with altered tendon fibril structure. Fibril diameter distributions in the decorin-null aged tendons were comparable to those observed in the mature wild type tendon with the absence of the subpopulation containing large diameter fibrils. Collectively, our findings provide evidence for age-dependent alterations in tendon architecture and functional activity, and further show that lack of stromal decorin attenuates these changes. PMID:23178232

  13. The biophysical characteristics of human composite flexor tendon allograft for upper extremity reconstruction.

    PubMed

    DeGeorge, Brent R; Rodeheaver, George T; Drake, David B

    2014-01-01

    Devastating volar hand injuries with significant damage to the skin and soft tissues, pulley structures and fibro-osseous sheath, flexor tendons, and volar plates pose a major problem to the reconstructive hand surgeon. Despite advances in tendon handling, operative technique, and postoperative hand rehabilitation, patients who have undergone flexor tendon reconstruction are often plagued by chronic pain, stiffness, and decreased range of motion with resultant decreased ability to work and poor quality of life. In this article, we expand the technique of human composite flexor tendon allografts (CFTAs), pioneered by Dr E.E. Peacock, Jr, which consist of both the intrasynovial and extrasynovial flexor digitorum superficialis and flexor digitorum profundus tendons and their respective fibro-osseous sheath consisting of the digital pulley structures, periosteum, and volar plates procured from cadaveric donors with the use of modern tissue processing techniques. Human cadaveric CFTAs were procured and divided into 2 groups-unprocessed CFTAs and processed CFTAs, which are cleansed and sterilized to a sterility assurance level of 10(-6). Physical length and width relationships as well as tensile strength and gliding resistance assessments were recorded pre-tissue and post-tissue processing. The histologic properties of the composite allografts were assessed before and after tissue processing. There was no significant difference with respect to physical properties of the composite allografts before or after tissue processing. The processed composite allografts demonstrated equivalent maximum load to failure and elastic modulus compared to unprocessed tendons. The gliding resistance of the composite tendon allografts was not significantly different between the 2 groups. The use of CFTAs addresses the issues of adhesion formation and lack of suitable donor material by providing a source of intrasynovial tendon in its unaltered fibro-osseous sheath without donor morbidity. This approach represents an important step toward designing an ideal material for complex flexor tendon reconstruction, which takes advantage of an intrasynovial flexor tendon in its native fibro-osseous sheath without the need for additional donor morbidity using a construct which can be engineered to have minimal tissue reactivity, negligible potential for disease transmission, and improved tendon healing properties versus standard tendon allograft.

  14. Structural and Ultrastructural Characteristics of Bone-Tendon Junction of the Calcaneal Tendon of Adult and Elderly Wistar Rats

    PubMed Central

    Cury, Diego Pulzatto; Dias, Fernando José; Miglino, Maria Angélica; Watanabe, Ii-sei

    2016-01-01

    Tendons are transition tissues that transfer the contractile forces generated by the muscles to the bones, allowing movement. The region where the tendon attaches to the bone is called bone-tendon junction or enthesis and may be classified as fibrous or fibrocartilaginous. This study aims to analyze the collagen fibers and the cells present in the bone-tendon junction using light microscopy and ultrastructural techniques as scanning electron microscopy and transmission electron microscopy. Forty male Wistar rats were used in the experiment, being 20 adult rats at 4 months-old and 20 elderly rats at 20 months-old. The hind limbs of the rats were removed, dissected and prepared to light microscopy, transmission electron microscopy and scanning electron microscopy. The aging process showed changes in the collagen fibrils, with a predominance of type III fibers in the elderly group, in addition to a decrease in the amount of the fibrocartilage cells, fewer and shorter cytoplasmic processes and a decreased synthetic capacity due to degradation of the organelles involved in synthesis. PMID:27078690

  15. Structural and Ultrastructural Characteristics of Bone-Tendon Junction of the Calcaneal Tendon of Adult and Elderly Wistar Rats.

    PubMed

    Cury, Diego Pulzatto; Dias, Fernando José; Miglino, Maria Angélica; Watanabe, Ii-sei

    2016-01-01

    Tendons are transition tissues that transfer the contractile forces generated by the muscles to the bones, allowing movement. The region where the tendon attaches to the bone is called bone-tendon junction or enthesis and may be classified as fibrous or fibrocartilaginous. This study aims to analyze the collagen fibers and the cells present in the bone-tendon junction using light microscopy and ultrastructural techniques as scanning electron microscopy and transmission electron microscopy. Forty male Wistar rats were used in the experiment, being 20 adult rats at 4 months-old and 20 elderly rats at 20 months-old. The hind limbs of the rats were removed, dissected and prepared to light microscopy, transmission electron microscopy and scanning electron microscopy. The aging process showed changes in the collagen fibrils, with a predominance of type III fibers in the elderly group, in addition to a decrease in the amount of the fibrocartilage cells, fewer and shorter cytoplasmic processes and a decreased synthetic capacity due to degradation of the organelles involved in synthesis.

  16. Loss of Drosophila A-type lamin C initially causes tendon abnormality including disintegration of cytoskeleton and nuclear lamina in muscular defects.

    PubMed

    Uchino, Ryo; Nonaka, Yu-Ki; Horigome, Tuneyoshi; Sugiyama, Shin; Furukawa, Kazuhiro

    2013-01-01

    Lamins are the major components of nuclear envelope architecture, being required for both the structural and informational roles of the nuclei. Mutations of lamins cause a spectrum of diseases in humans, including muscular dystrophy. We report here that the loss of the A-type lamin gene, lamin C in Drosophila resulted in pupal metamorphic lethality caused by tendon defects, matching the characteristics of human A-type lamin revealed by Emery-Dreifuss muscular dystrophy (EDMD). In tendon cells lacking lamin C activity, overall cell morphology was affected and organization of the spectraplakin family cytoskeletal protein Shortstop which is prominently expressed in tendon cells gradually disintegrated, notably around the nucleus and in a manner correlating well with the degradation of musculature. Furthermore, lamin C null mutants were efficiently rescued by restoring lamin C expression to shortstop-expressing cells, which include tendon cells but exclude skeletal muscle cells. Thus the critical function of A-type lamin C proteins in Drosophila musculature is to maintain proper function and morphology of tendon cells. Copyright © 2012 Elsevier Inc. All rights reserved.

  17. Three dimensional microstructural network of elastin, collagen, and cells in Achilles tendons.

    PubMed

    Pang, Xin; Wu, Jian-Ping; Allison, Garry T; Xu, Jiake; Rubenson, Jonas; Zheng, Ming-Hao; Lloyd, David G; Gardiner, Bruce; Wang, Allan; Kirk, Thomas Brett

    2017-06-01

    Similar to most biological tissues, the biomechanical, and functional characteristics of the Achilles tendon are closely related to its composition and microstructure. It is commonly reported that type I collagen is the predominant component of tendons and is mainly responsible for the tissue's function. Although elastin has been found in varying proportions in other connective tissues, previous studies report that tendons contain very small quantities of elastin. However, the morphology and the microstructural relationship among the elastic fibres, collagen, and cells in tendon tissue have not been well examined. We hypothesize the elastic fibres, as another fibrillar component in the extracellular matrix, have a unique role in mechanical function and microstructural arrangement in Achilles tendons. It has been shown that elastic fibres present a close connection with the tenocytes. The close relationship of the three components has been revealed as a distinct, integrated and complex microstructural network. Notably, a "spiral" structure within fibril bundles in Achilles tendons was observed in some samples in specialized regions. This study substantiates the hierarchical system of the spatial microstructure of tendon, including the mapping of collagen, elastin and tenocytes, with 3-dimensional confocal images. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1203-1214, 2017. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  18. Regional stiffening with aging in tibialis anterior tendons of mice occurs independent of changes in collagen fibril morphology

    PubMed Central

    Wood, Lauren K.; Arruda, Ellen M.

    2011-01-01

    The incidence of tendon degeneration and rupture increases with advancing age. The mechanisms underlying this increased risk remain unknown but may arise because of age-related changes in tendon mechanical properties and structure. Our purpose was to determine the effect of aging on tendon mechanical properties and collagen fibril morphology. Regional mechanical properties and collagen fibril characteristics were determined along the length of tibialis anterior (TA) tendons from adult (8- to 12-mo-old) and old (28- to 30-mo-old) mice. Tangent modulus of all regions along the tendons increased in old age, but the increase was substantially greater in the proximal region adjacent to the muscle than in the rest of the tendon. Overall end-to-end modulus increased with old age at maximum tendon strain (799 ± 157 vs. 1,419 ± 91 MPa) and at physiologically relevant strain (377 ± 137 vs. 798 ± 104 MPa). Despite the dramatic changes in tendon mechanical properties from adulthood to old age, collagen fibril morphology and packing fraction remained relatively constant in all tendon regions examined. Since tendon properties are influenced by their external loading environment, we also examined the effect of aging on TA muscle contractile properties. Maximum isometric force did not differ between the age groups. We conclude that TA tendons stiffen in a region-dependent manner throughout the life span, but the changes in mechanical properties are not accompanied by corresponding changes in collagen fibril morphology or force-generating capacity of the TA muscle. PMID:21737825

  19. Proprioception in the extraocular muscles of mammals and man.

    PubMed

    Blumer, Roland; Konacki, Kadriye Zeynep; Streicher, Johannes; Hoetzenecker, Wolfram; Blumer, Michael Josef Franz; Lukas, Julius-Robert

    2006-06-01

    This article summarizes the authors' previous studies on proprioceptors in extraocular muscles (EOMs) of mammals and man. They report on muscle spindles in the EOMs of man, Golgi tendon organs in the EOMs of even-toed ungulates, and palisade endings in the EOMs of the cat. Muscle spindles: Muscle spindles are present in the EOMs of some mammals and in the EOMs of man. Compared with muscle spindles in other skeletal muscles, those in human EOMs exhibit structural differences. These structural differences may indicate a special function. Golgi tendon organs: Golgi tendon organs are absent in human EOMs. Golgi tendon organs exhibiting a specific morphology are present in the EOMs of even-toed ungulates. Their high number and rich innervation indicate functional importance. Palisade endings: Palisade endings are nervous end organs confined to the EOMs of mammals and man. It is assumed that these organs have a proprioceptive function. The authors show that palisade endings are immunoreactive for antibodies against choline acetyltransferase. Neuromuscular contacts, if present in palisade endings, are alpha -bungarotoxin positive as well. Taken together, these results show that palisade endings exhibit molecular characteristics of effector organs.

  20. Structure-function relationships in tendons: a review

    PubMed Central

    Benjamin, M; Kaiser, E; Milz, S

    2008-01-01

    The purpose of the current review is to highlight the structure-function relationship of tendons and related structures to provide an overview for readers whose interest in tendons needs to be underpinned by anatomy. Because of the availability of several recent reviews on tendon development and entheses, the focus of the current work is primarily directed towards what can best be described as the ‘tendon proper’ or the ‘mid-substance’ of tendons. The review covers all levels of tendon structure from the molecular to the gross and deals both with the extracellular matrix and with tendon cells. The latter are often called ‘tenocytes’ and are increasingly recognized as a defined cell population that is functionally and phenotypically distinct from other fibroblast-like cells. This is illustrated by their response to different types of mechanical stress. However, it is not only tendon cells, but tendons as a whole that exhibit distinct structure-function relationships geared to the changing mechanical stresses to which they are subject. This aspect of tendon biology is considered in some detail. Attention is briefly directed to the blood and nerve supply of tendons, for this is an important issue that relates to the intrinsic healing capacity of tendons. Structures closely related to tendons (joint capsules, tendon sheaths, pulleys, retinacula, fat pads and bursae) are also covered and the concept of a ‘supertendon’ is introduced to describe a collection of tendons in which the function of the whole complex exceeds that of its individual members. Finally, attention is drawn to the important relationship between tendons and fascia, highlighted by Wood Jones in his concept of an ‘ectoskeleton’ over half a century ago – work that is often forgotten today. PMID:18304204

  1. Molecular Characteristics of the Equine Periodontal Ligament

    PubMed Central

    Pöschke, Antje; Krähling, Bastian; Failing, Klaus; Staszyk, Carsten

    2018-01-01

    The equine periodontal ligament (PDL) is a fibrous connective tissue that covers the intra-alveolar parts of the tooth and anchors it to the alveolar bone—it, therefore, provides a similar function to a tendinous structure. While several studies have considered the formation and structure of tendons, there is insufficient information particularly on the molecular composition of the PDL. Especially for the equine PDL, there is limited knowledge concerning the expression of genes commonly regarded as typical for tendon tissue. In this study, the gene expression of, e.g., collagen type 1 alpha 1 (COL1), collagen type 3 alpha 1 (COL3), scleraxis (SCX), and fibrocartilage markers was examined in the functional mature equine PDL compared with immature and mature equine tendon tissue. PDL samples were obtained from incisor, premolar, and molar teeth from seven adult horses. Additionally, tendon samples were collected from four adult horses and five foals at different sampling locations. Analyses of gene expression were performed using real-time quantitative polymerase chain reaction (qRT-PCR). Significantly higher expression levels of COL1 and 3 were found in the mature equine PDL in comparison with mature tendon, indicating higher rates of collagen production and turnover in the mature equine PDL. The expression levels of SCX, a specific marker for tenogenic-differentiated cells, were on a similar level in functional mature PDL and in mature tendon tissue. Evidence of chondrogenic metaplasia, often found in tendon entheses or in pressurized regions of tendons, was not found in the mature equine PDL. The obtained results justify further experiments focused on the possible use of equine PDL cells for cell-based regenerative therapies. PMID:29376061

  2. Achilles tendons from decorin- and biglycan-null mouse models have inferior mechanical and structural properties predicted by an image-based empirical damage model

    PubMed Central

    Gordon, J.A.; Freedman, B.R.; Zuskov, A.; Iozzo, R.V.; Birk, D.E.; Soslowsky, L.J.

    2015-01-01

    Achilles tendons are a common source of pain and injury, and their pathology may originate from aberrant structure function relationships. Small leucine rich proteoglycans (SLRPs) influence mechanical and structural properties in a tendon-specific manner. However, their roles in the Achilles tendon have not been defined. The objective of this study was to evaluate the mechanical and structural differences observed in mouse Achilles tendons lacking class I SLRPs; either decorin or biglycan. In addition, empirical modeling techniques based on mechanical and image-based measures were employed. Achilles tendons from decorin-null (Dcn−/−) and biglycan-null (Bgn−/−) C57BL/6 female mice (N=102) were used. Each tendon underwent a dynamic mechanical testing protocol including simultaneous polarized light image capture to evaluate both structural and mechanical properties of each Achilles tendon. An empirical damage model was adapted for application to genetic variation and for use with image based structural properties to predict tendon dynamic mechanical properties. We found that Achilles tendons lacking decorin and biglycan had inferior mechanical and structural properties that were age dependent; and that simple empirical models, based on previously described damage models, were predictive of Achilles tendon dynamic modulus in both decorin- and biglycan-null mice. PMID:25888014

  3. Achilles tendons from decorin- and biglycan-null mouse models have inferior mechanical and structural properties predicted by an image-based empirical damage model.

    PubMed

    Gordon, J A; Freedman, B R; Zuskov, A; Iozzo, R V; Birk, D E; Soslowsky, L J

    2015-07-16

    Achilles tendons are a common source of pain and injury, and their pathology may originate from aberrant structure function relationships. Small leucine rich proteoglycans (SLRPs) influence mechanical and structural properties in a tendon-specific manner. However, their roles in the Achilles tendon have not been defined. The objective of this study was to evaluate the mechanical and structural differences observed in mouse Achilles tendons lacking class I SLRPs; either decorin or biglycan. In addition, empirical modeling techniques based on mechanical and image-based measures were employed. Achilles tendons from decorin-null (Dcn(-/-)) and biglycan-null (Bgn(-/-)) C57BL/6 female mice (N=102) were used. Each tendon underwent a dynamic mechanical testing protocol including simultaneous polarized light image capture to evaluate both structural and mechanical properties of each Achilles tendon. An empirical damage model was adapted for application to genetic variation and for use with image based structural properties to predict tendon dynamic mechanical properties. We found that Achilles tendons lacking decorin and biglycan had inferior mechanical and structural properties that were age dependent; and that simple empirical models, based on previously described damage models, were predictive of Achilles tendon dynamic modulus in both decorin- and biglycan-null mice. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Different Achilles Tendon Pathologies Show Distinct Histological and Molecular Characteristics

    PubMed Central

    Minkwitz, Susann; Schmock, Aysha; Bormann, Nicole; Kurtoglu, Alper; Tsitsilonis, Serafeim; Manegold, Sebastian

    2018-01-01

    Reasons for the development of chronic tendon pathologies are still under debate and more basic knowledge is needed about the different diseases. The aim of the present study was therefore to characterize different acute and chronic Achilles tendon disorders. Achilles tendon samples from patients with chronic tendinopathy (n = 7), chronic ruptures (n = 6), acute ruptures (n = 13), and intact tendons (n = 4) were analyzed. The histological score investigating pathological changes was significantly increased in tendinopathy and chronic ruptures compared to acute ruptures. Inflammatory infiltration was detected by immunohistochemistry in all tendon pathology groups, but was significantly lower in tendinopathy compared to chronic ruptures. Quantitative real-time PCR (qRT-PCR) analysis revealed significantly altered expression of genes related to collagens and matrix modeling/remodeling (matrix metalloproteinases, tissue inhibitors of metalloproteinases) in tendinopathy and chronic ruptures compared to intact tendons and/or acute ruptures. In all three tendon pathology groups markers of inflammation (interleukin (IL) 1β, tumor necrosis factor α, IL6, IL10, IL33, soluble ST2, transforming growth factor β1, cyclooxygenase 2), inflammatory cells (cluster of differentaition (CD) 3, CD68, CD80, CD206), fat metabolism (fatty acid binding protein 4, peroxisome proliferator-activated receptor γ, CCAAT/enhancer-binding protein α, adiponectin), and innervation (protein gene product 9.5, growth associated protein 43, macrophage migration inhibitory factor) were detectable, but only in acute ruptures significantly regulated compared to intact tendons. The study gives an insight into structural and molecular changes of pathological processes in tendons and might be used to identify targets for future therapy of tendon pathologies. PMID:29385715

  5. Rotator cuff tendon connections with the rotator cable.

    PubMed

    Rahu, Madis; Kolts, Ivo; Põldoja, Elle; Kask, Kristo

    2017-07-01

    The literature currently contains no descriptions of the rotator cuff tendons, which also describes in relation to the presence and characteristics of the rotator cable (anatomically known as the ligamentum semicirculare humeri). The aim of the current study was to elucidate the detailed anatomy of the rotator cuff tendons in association with the rotator cable. Anatomic dissection was performed on 21 fresh-frozen shoulder specimens with an average age of 68 years. The rotator cuff tendons were dissected from each other and from the glenohumeral joint capsule, and the superior glenohumeral, coracohumeral, coracoglenoidal and semicircular (rotator cable) ligaments were dissected. Dissection was performed layer by layer and from the bursal side to the joint. All ligaments and tendons were dissected in fine detail. The rotator cable was found in all specimens. It was tightly connected to the supraspinatus (SSP) tendon, which was partly covered by the infraspinatus (ISP) tendon. The posterior insertion area of the rotator cable was located in the region between the middle and inferior facets of the greater tubercle of the humerus insertion areas for the teres minor (TM), and ISP tendons were also present and fibres from the SSP extended through the rotator cable to those areas. The connection between the rotator cable and rotator cuff tendons is tight and confirms the suspension bridge theory for rotator cuff tears in most areas between the SSP tendons and rotator cable. In its posterior insertion area, the rotator cable is a connecting structure between the TM, ISP and SSP tendons. These findings might explain why some patients with relatively large rotator cuff tears can maintain seamless shoulder function.

  6. In vitro characterization of a novel tissue engineered based hybridized nano and micro structured collagen implant and its in vivo role on tenoinduction, tenoconduction, tenogenesis and tenointegration.

    PubMed

    Oryan, Ahmad; Moshiri, Ali; Meimandi-Parizi, Abdolhamid

    2014-03-01

    Surgical reconstruction of large tendon defects is technically demanding. Tissue engineering is a new option. We produced a novel tissue engineered, collagen based, bioimplant and in vitro characterizations of the implant were investigated. In addition, we investigated role of the collagen implant on the healing of a large tendon defect model in rabbits. A two cm length of the left rabbit's Achilles tendon was transected and discarded. The injured tendons of all the rabbits were repaired by Kessler pattern to create and maintain a 2 cm tendon gap. The collagen implant was inserted in the tendon defect of the treatment group (n = 30). The defect area was left intact in the control group (n = 30). The animals were euthanized at 60 days post injury (DPI) and the macro- micro- and nano- morphologies and the biomechanical characteristics of the tendon samples were studied. Differences of P < 0.05 were considered significant. The host graft interaction was followed at various stages of tendon healing, using pilot animals. At 60 DPI, a significant increase in number, diameter and density of the collagen fibrils, number and maturity of tenoblasts and tenocytes, alignment of the collagen fibrils and maturity of the elastic fibers were seen in the treated tendons when compared to the control ones (P < 0.05). Compared to the control lesions, number of inflammatory cells, amount of peritendinous adhesions and muscle fibrosis and atrophy, were significantly lower in the treated lesions (P < 0.05). Treatment also significantly increased load to failure, tensile strength and elastic modulus of the samples as compared with the control ones. The collagen implant properly incorporated with the healing tissue and was replaced by the new tendinous structure which was superior both ultra-structurally and physically than the loose areolar connective tissue regenerated in the control lesions. The results of this study may be valuable in the clinical practice.

  7. The Tendon Structure Returns to Asymptomatic Values in Nonoperatively Treated Achilles Tendinopathy but Is Not Associated With Symptoms: A Prospective Study.

    PubMed

    de Jonge, Suzan; Tol, Johannes L; Weir, Adam; Waarsing, Jan H; Verhaar, Jan A N; de Vos, Robert-Jan

    2015-12-01

    Tendinopathy is characterized by alterations in the tendon structure, but there are conflicting results on the potential of tendon structure normalization and no large studies on the quantified, ultrasonographic tendon structure and its association with symptoms. To determine whether the tendon structure returns to values of asymptomatic individuals after treatment with 2 substances injected within the tendon, to assess the association between the tendon structure and symptoms, and to assess the prognostic value of the baseline tendon structure on treatment response. Cohort study; Level of evidence, 2. This study was part of a randomized trial on chronic midportion Achilles tendinopathy using eccentric exercises with either a platelet-rich plasma or saline injection. Symptoms were recorded using the Victorian Institute of Sports Assessment-Achilles (VISA-A) questionnaire. The tendon structure was quantified with ultrasound tissue characterization (UTC); echo types I + II (as a percentage of total tendon types I-IV) are structure related. Follow-up was at 6, 12, 24, and 52 weeks. A control group of asymptomatic subjects (similar age) was selected to compare the tendon structure. Patient symptoms were correlated with the tendon structure using a linear model. Fifty-four patients were included in the symptomatic group. The mean (± SD) echo types I + II in the symptomatic group increased significantly from 74.6% ± 10.8% at baseline to 85.6% ± 6.0% at 24-week follow-up. The result for echo types I + II at 24 weeks was not significantly different (P = .198) from that of the asymptomatic control group (87.5% ± 6.0%). In 54 repeated measurements at 5 time points, the adjusted percentage of echo types I + II was not associated with the VISA-A score (main effect: β = .12; 95% CI, -0.12 to 0.35; P = .338). The adjusted baseline echo types I + II were not associated with a change in the VISA-A score from baseline to 52 weeks (β = -.15; 95% CI, -0.67 to 0.36; P = .555). In symptomatic, tendinopathic Achilles tendons, the ultrasonographic tendon structure improved during nonoperative treatment and normalized after 24 weeks to values of matched asymptomatic controls. There was no association between the tendon structure and symptoms. The percentage of echo types I + II before treatment was not associated with change in symptoms over time. This study demonstrates that restoration of the tendon structure is not required for an improvement of symptoms. © 2015 The Author(s).

  8. Single versus double-row repair of the rotator cuff: does double-row repair with improved anatomical and biomechanical characteristics lead to better clinical outcome?

    PubMed

    Pauly, Stephan; Gerhardt, Christian; Chen, Jianhai; Scheibel, Markus

    2010-12-01

    Several techniques for arthroscopic repair of rotator cuff defects have been introduced over the past years. Besides established techniques such as single-row repairs, new techniques such as double-row reconstructions have gained increasing interest. The present article therefore provides an overview of the currently available literature on both repair techniques with respect to several anatomical, biomechanical, clinical and structural endpoints. Systematic literature review of biomechanical, clinical and radiographic studies investigating or comparing single- and double-row techniques. These results were evaluated and compared to provide an overview on benefits and drawbacks of the respective repair type. Reconstructions of the tendon-to-bone unit for full-thickness tears in either single- or double-row technique differ with respect to several endpoints. Double-row repair techniques provide more anatomical reconstructions of the footprint and superior initial biomechanical characteristics when compared to single-row repair. With regard to clinical results, no significant differences were found while radiological data suggest a better structural tendon integrity following double-row fixation. Presently published clinical studies cannot emphasize a clearly superior technique at this time. Available biomechanical studies are in favour of double-row repair. Radiographic studies suggest a beneficial effect of double-row reconstruction on structural integrity of the reattached tendon or reduced recurrent defect rates, respectively.

  9. Role of tissue-engineered artificial tendon in healing of a large Achilles tendon defect model in rabbits.

    PubMed

    Moshiri, Ali; Oryan, Ahmad; Meimandi-Parizi, Abdolhamid

    2013-09-01

    Treatment of large Achilles tendon defects is technically demanding. Tissue engineering is an option. We constructed a collagen-based artificial tendon, covered it with a polydioxanon (PDS) sheath, and studied the role of this bioimplant on experimental tendon healing in vivo. A 2-cm tendon gap was created in the left Achilles tendon of rabbits (n = 120). The animals were randomly divided into 3 groups: control (no implant), treated with tridimensional-collagen, and treated with tridimensional-collagen-bidimensional-PDS implants. Each group was divided into 2 subgroups of 60 and 120 days postinjury (DPI). Another 50 pilot animals were used to study the host-implant interaction. Physical activity of the animals was scored and ultrasonographic and bioelectrical characteristics of the injured tendons were investigated weekly. After euthanasia, macro, micro, and nano morphologies and biophysical and biomechanical characteristics of the healing tendons were studied. Treatment improved function of the animals, time dependently. At 60 and 120 DPI, the treated tendons showed significantly higher maximum load, yield, stiffness, stress, and modulus of elasticity compared with controls. The collagen implant induced inflammation and absorbed the migrating fibroblasts in the defect area. By its unique architecture, it aligned the fibroblasts and guided their proliferation and collagen deposition along the stress line of the tendon and resulted in improved collagen density, micro-amp, micro-ohm, water uptake, and delivery of the regenerated tissue. The PDS-sheath covering amplified these characteristics. The implants were gradually absorbed and replaced by a new tendon. Minimum amounts of peritendinous adhesion, muscle atrophy, and fibrosis were observed in the treated groups. Some remnants of the implants were preserved and accepted as a part of the new tendon. The implants were cytocompatible, biocompatible, biodegradable, and effective in tendon healing and regeneration. This implant may be a valuable option in clinical practice. Copyright © 2013 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  10. A Comparative Study of Clinical Outcomes and Second-Look Arthroscopic Findings between Remnant-Preserving Tibialis Tendon Allograft and Hamstring Tendon Autograft in Anterior Cruciate Ligament Reconstruction: Matched-Pair Design.

    PubMed

    Kim, You Keun; Ahn, Jong Hyun; Yoo, Jae Doo

    2017-12-01

    This study aimed to compare stability, functional outcome, and second-look arthroscopic findings after anterior cruciate ligament reconstruction between remnant-preserving tibialis tendon allograft and remnant-sacrificing hamstring tendon autograft. We matched two groups (remnant-preserving tibialis tendon allograft group and hamstring tendon autograft group) in terms of demographic characteristics, associated injury, and knee characteristics. Each group consisted of 25 patients. Operation time was longer in the remnant-preserving tibialis tendon allograft group, but there was no significant intergroup difference in stability, clinical outcome, and second-look arthroscopic findings. When an autograft is not feasible in anterior cruciate ligament reconstruction, the remnant-preserving technique can produce comparable results in terms of restoration of function, stability of the knee, and degree of synovium coverage at second-look arthroscopy compared to remnant-sacrificing hamstring autograft.

  11. Proteomic differences between native and tissue‐engineered tendon and ligament

    PubMed Central

    Tew, Simon R.; Peffers, Mandy; Canty‐Laird, Elizabeth G.; Comerford, Eithne

    2016-01-01

    Tendons and ligaments (T/Ls) play key roles in the musculoskeletal system, but they are susceptible to traumatic or age‐related rupture, leading to severe morbidity as well as increased susceptibility to degenerative joint diseases such as osteoarthritis. Tissue engineering represents an attractive therapeutic approach to treating T/L injury but it is hampered by our poor understanding of the defining characteristics of the two tissues. The present study aimed to determine differences in the proteomic profile between native T/Ls and tissue engineered (TE) T/L constructs. The canine long digital extensor tendon and anterior cruciate ligament were analyzed along with 3D TE fibrin‐based constructs created from their cells. Native tendon and ligament differed in their content of key structural proteins, with the ligament being more abundant in fibrocartilaginous proteins. 3D T/L TE constructs contained less extracellular matrix (ECM) proteins and had a greater proportion of cellular‐associated proteins than native tissue, corresponding to their low collagen and high DNA content. Constructs were able to recapitulate native T/L tissue characteristics particularly with regard to ECM proteins. However, 3D T/L TE constructs had similar ECM and cellular protein compositions indicating that cell source may not be an important factor for T/L tissue engineering. PMID:27080496

  12. Monitoring based maintenance utilizing actual stress sensory technology

    NASA Astrophysics Data System (ADS)

    Sumitro, Sunaryo; Kurokawa, Shoji; Shimano, Keiji; Wang, Ming L.

    2005-06-01

    In recent years, many infrastructures have been deteriorating. In order to maintain sustainability of those infrastructures which have significant influence on social lifelines, economical and rational maintenance management should be carried out to evaluate the life cycle cost (LCC). The development of structural health monitoring systems, such as deriving evaluation techniques for the field structural condition of existing structures and identification techniques for the significant engineering properties of new structures, can be considered as the first step in resolving the above problem. New innovative evaluation methods need to be devised to identify the deterioration of infrastructures, e.g. steel tendons, cables in cable-stayed bridges and strands embedded in pre- or post-tensioned concrete structures. One of the possible solutions that show 'AtoE' characteristics, i.e., (a)ccuracy, (b)enefit, (c)ompendiousness, (d)urability and (e)ase of operation, elasto-magnetic (EM) actual stress sensory technology utilizing the sensitivity of incremental magnetic permeability to stress change, has been developed. Numerous verification tests on various steel materials have been conducted. By comparing with load cell, strain gage and other sensory technology measurement results, the actual stresses of steel tendons in a pre-stressed concrete structure at the following stages have been thoroughly investigated: (i) pre-stress change due to set-loss (anchorage slippage) at the tendon fixation stage; (ii) pre-stress change due to the tendon relaxation stage; (iii) concrete creep and shrinkage at the long term pre-stressing stage; (iv) pre-stress change in the cyclic fatigue loading stage; and (v) pre-stress change due to the re-pre-stress setting stage. As the result of this testing, it is confirmed that EM sensory technology enables one to measure actual stress in steel wire, strands and steel bars precisely without destroying the polyethylene covering sheath and enables one to provide adequate accuracy and reliability for monitoring actual stresses of those steel tendons during the life cycle of infrastructures. An example of a field application at a cable-stayed bridge is described.

  13. Experimental and Computational Investigation of Viscoelasticity of Native and Engineered Ligament and Tendon

    NASA Astrophysics Data System (ADS)

    Ma, J.; Narayanan, H.; Garikipati, K.; Grosh, K.; Arruda, E. M.

    The important mechanisms by which soft collagenous tissues such as ligament and tendon respond to mechanical deformation include non-linear elasticity, viscoelasticity and poroelasticity. These contributions to the mechanical response are modulated by the content and morphology of structural proteins such as type I collagen and elastin, other molecules such as glycosaminoglycans, and fluid. Our ligament and tendon constructs, engineered from either primary cells or bone marrow stromal cells and their autogenous matricies, exhibit histological and mechanical characteristics of native tissues of different levels of maturity. In order to establish whether the constructs have optimal mechanical function for implantation and utility for regenerative medicine, constitutive relationships for the constructs and native tissues at different developmental levels must be established. A micromechanical model incorporating viscoelastic collagen and non-linear elastic elastin is used to describe the non-linear viscoelastic response of our homogeneous engineered constructs in vitro. This model is incorporated within a finite element framework to examine the heterogeneity of the mechanical responses of native ligament and tendon.

  14. Collagen fibrils in functionally distinct tendons have differing structural responses to tendon rupture and fatigue loading.

    PubMed

    Herod, Tyler W; Chambers, Neil C; Veres, Samuel P

    2016-09-15

    In this study we investigate relationships between the nanoscale structure of collagen fibrils and the macroscale functional response of collagenous tissues. To do so, we study two functionally distinct classes of tendons, positional tendons and energy storing tendons, using a bovine forelimb model. Molecular-level assessment using differential scanning calorimetry (DSC), functional crosslink assessment using hydrothermal isometric tension (HIT) analysis, and ultrastructural assessment using scanning electron microscopy (SEM) were used to study undamaged, ruptured, and cyclically loaded samples from the two tendon types. HIT indicated differences in both crosslink type and crosslink density, with flexor tendons having more thermally stable crosslinks than the extensor tendons (higher TFmax of >90 vs. 75.1±2.7°C), and greater total crosslink density than the extensor tendons (higher t1/2 of 11.5±1.9 vs. 3.5±1.0h after NaBH4 treatment). Despite having a lower crosslink density than flexor tendons, extensor tendons were significantly stronger (37.6±8.1 vs. 23.1±7.7MPa) and tougher (14.3±3.6 vs. 6.8±3.4MJ/m(3)). SEM showed that collagen fibrils in the tougher, stronger extensor tendons were able to undergo remarkable levels of plastic deformation in the form of discrete plasticity, while those in the flexor tendons were not able to plastically deform. When cyclically loaded, collagen fibrils in extensor tendons accumulated fatigue damage rapidly in the form of kink bands, while those in flexor tendons did not accumulate significant fatigue damage. The results demonstrate that collagen fibrils in functionally distinct tendons respond differently to mechanical loading, and suggests that fibrillar collagens may be subject to a strength vs. fatigue resistance tradeoff. Collagen fibrils-nanoscale biological cables-are the fundamental load-bearing elements of all structural human tissues. While all collagen fibrils share common features, such as being composed of a precise quarter-staggered polymeric arrangement of triple-helical collagen molecules, their structure can vary significantly between tissue types, and even between different anatomical structures of the same tissue type. To understand normal function, homeostasis, and disease of collagenous tissues requires detailed knowledge of collagen fibril structure-function. Using anatomically proximate but structurally distinct tendons, we show that collagen fibrils in functionally distinct tendons have differing susceptibilities to damage under both tensile overload and cyclic fatigue loading. Our results suggest that the structure of collagen fibrils may lead to a strength versus fatigue resistance tradeoff, where high strength is gained at the expense of fatigue resistance, and vice versa. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  15. Collagen structure of tendon relates to function.

    PubMed

    Franchi, Marco; Trirè, Alessandra; Quaranta, Marilisa; Orsini, Ester; Ottani, Victoria

    2007-03-30

    A tendon is a tough band of fibrous connective tissue that connects muscle to bone, designed to transmit forces and withstand tension during muscle contraction. Tendon may be surrounded by different structures: 1) fibrous sheaths or retinaculae; 2) reflection pulleys; 3) synovial sheaths; 4) peritendon sheaths; 5) tendon bursae. Tendons contain a) few cells, mostly represented by tenoblasts along with endothelial cells and some chondrocytes; b) proteoglycans (PGs), mainly decorin and hyaluronan, and c) collagen, mostly type I. Tendon is a good example of a high ordered extracellular matrix in which collagen molecules assemble into filamentous collagen fibrils (formed by microfibrils) which aggregate to form collagen fibers, the main structural components. It represents a multihierarchical structure as it contains collagen molecules arranged in fibrils then grouped in fibril bundles, fascicles and fiber bundles that are almost parallel to the long axis of the tendon, named as primary, secondary and tertiary bundles. Collagen fibrils in tendons show prevalently large diameter, a D-period of about 67 nm and appear built of collagen molecules lying at a slight angle (< 5 degrees). Under polarized light microscopy the collagen fiber bundles appear crimped with alternative dark and light transverse bands. In recent studies tendon crimps observed via SEM and TEM show that the single collagen fibrils suddenly changing their direction contain knots. These knots of collagen fibrils inside each tendon crimp have been termed "fibrillar crimps", and even if they show different aspects they all may fulfil the same functional role. As integral component of musculoskeletal system, the tendon acts to transmit muscle forces to the skeletal system. There is no complete understanding of the mechanisms in transmitting/absorbing tensional forces within the tendon; however it seems likely that a flattening of tendon crimps may occur at a first stage of tendon stretching. Increasing stretching, other transmission mechanisms such as an interfibrillar coupling via PGs linkages and a molecular gliding within the fibrils structure may be involved.

  16. Extracellular matrix adaptation of tendon and skeletal muscle to exercise

    PubMed Central

    Kjær, Michael; Magnusson, Peter; Krogsgaard, Michael; Møller, Jens Boysen; Olesen, Jens; Heinemeier, Katja; Hansen, Mette; Haraldsson, Bjarki; Koskinen, Satu; Esmarck, Birgitte; Langberg, Henning

    2006-01-01

    The extracellular matrix (ECM) of connective tissues enables linking to other tissues, and plays a key role in force transmission and tissue structure maintenance in tendons, ligaments, bone and muscle. ECM turnover is influenced by physical activity, and both collagen synthesis and metalloprotease activity increase with mechanical loading. This can be shown by determining propeptide and proteinase activity by microdialysis, as well as by verifying the incorporation of infused stable isotope amino acids in biopsies. Local tissue expression and release of growth factors for ECM such as IGF-1, TGF-beta and IL-6 is enhanced following exercise. For tendons, metabolic activity (e.g. detected by positron emission tomography scanning), circulatory responses (e.g. as measured by near-infrared spectroscopy and dye dilution) and collagen turnover are markedly increased after exercise. Tendon blood flow is regulated by cyclooxygenase-2 (COX-2)-mediated pathways, and glucose uptake is regulated by specific pathways in tendons that differ from those in skeletal muscle. Chronic loading in the form of physical training leads both to increased collagen turnover as well as to some degree of net collagen synthesis. These changes modify the mechanical properties and the viscoelastic characteristics of the tissue, decrease its stress-susceptibility and probably make it more load-resistant. The mechanical properties of tendon fascicles vary within a given human tendon, and even show gender differences. The latter is supported by findings of gender-related differences in the activation of collagen synthesis with exercise. These findings may provide the basis for understanding tissue overloading and injury in both tendons and skeletal muscle. PMID:16637870

  17. Efficacy of computerized discrimination between structure-related and non-structure-related echoes in ultrasonographic images for the quantitative evaluation of the structural integrity of superficial digital flexor tendons in horses.

    PubMed

    van Schie, H T; Bakker, E M; Jonker, A M; van Weeren, P R

    2001-07-01

    To evaluate effectiveness of computerized discrimination between structure-related and non-structure-related echoes in ultrasonographic images for quantitative evaluation of tendon structural integrity in horses. 4 superficial digital flexor tendons (2 damaged tendons, 2 normal tendons). Transverse ultrasonographic images that precisely matched histologic sections were obtained in fixed steps along the long axis of each tendon. Distribution, intensity, and delineation of structure-related echoes, quantitatively expressed as the correlation ratio and steadiness ratio , were compared with histologic findings in tissue that was normal or had necrosis, early granulation, late granulation, early fibrosis, or inferior repair. In normal tendon, the even distribution of structure-related echoes with high intensity and sharp delineation yielded high correlation ratio and steadiness ratio. In areas of necrosis, collapsed endotendon septa yielded solid but blurred structure-related echoes (high correlation ration and low steadiness ratio). In early granulation tissue, complete lack of organization caused zero values for both ratios. In late granulation tissue, reorganization and swollen endotendon septa yielded poorly delineated structure-related echoes (high correlation ratio, low steadiness ratio). In early fibrosis, rearrangement of bundles resulted in normal correlation ration and slightly low steadiness ratio. In inferior repair, the almost complete lack of structural reorganization resulted in heterogeneous poorly delineated low-intensity echoes (low correlation ratio and steadiness ratio). The combination of correlation ratio and steadiness ratio accurately reflects histopathologic findings, making computerized correlation of ultrasonographic images an efficient tool for quantitative evaluation of tendon structural integrity.

  18. Regional strain variations in the human patellar tendon.

    PubMed

    Pearson, Stephen J; Ritchings, Tim; Mohamed, Azlan S A

    2014-07-01

    Characteristics of localized tendon strain in vivo are largely unknown. The present study examines local tendon strain between the deep, middle, and surface structures at the proximal and distal aspects of the patellar tendon during ramped isometric contractions. Male subjects (age 28.0 ± 6.3 yr) were examined for patellar tendon excursion (anterior, midsection, and posterior) during ramped isometric voluntary contractions using real-time B-mode ultrasonography and dynamometry. Regional tendon excursion measurements were compared using an automated pixel tracking method. Strain was determined from the tendon delta length normalized to initial/resting segment length. Strain increased from 10% to 100% of force for all regions. Significantly greater mean strain was seen for the anterior proximal region compared to the posterior and mid layer of the tendon (7.5% ± 1.1% vs 3.7% ± 0.5% vs 5.5% ± 1.0%; P < 0.05). Similarly, the distal posterior region showed greater mean strain compared to the mid and anterior regions (7.9% ± 0.6% vs 5.0% ± 0.6% vs 5.4% ± 0.6%; P < 0.05). Relative changes in strain differences from 50% to 100% of force for the proximal region were greatest for the anterior to midline regions (4.6% ± 0.6% and 5.6% ± 0.6%, respectively) and those for the distal region were also greatest for the anterior to midline regions (4.4% ± 0.2% and 5.3% ± 0.2%, respectively). The largest mean strain for the proximal region was at the anterior layer (7.5% ± 1.1%) and that for the distal tendon region was at the posterior layer (7.9% ± 0.9%). This study shows significant regional differences in strain during ramped isometric contractions for the patellar tendon. Lower proximal strains in the posterior tendon compared to the anterior region may be associated with the suggestion of "stress shielding" as an etiological factor in insertional tendinopathy.

  19. Evaluating Changes in Tendon Crimp with Fatigue Loading as an ex vivo Structural Assessment of Tendon Damage

    PubMed Central

    Freedman, Benjamin R.; Zuskov, Andrey; Sarver, Joseph J.; Buckley, Mark R.; Soslowsky, Louis J.

    2015-01-01

    The complex structure of tendons relates to their mechanical properties. Previous research has associated the waviness of collagen fibers (crimp) during quasi-static tensile loading to tensile mechanics, but less is known about the role of fatigue loading on crimp properties. In this study (IACUC approved), mouse patellar tendons were fatigue loaded while an integrated plane polariscope simultaneously assessed crimp properties. We demonstrate a novel structural mechanism whereby tendon crimp amplitude and frequency are altered with fatigue loading. In particular, fatigue loading increased the crimp amplitude across the tendon width and length, and these structural alterations were shown to be both region and load dependent. The change in crimp amplitude was strongly correlated to mechanical tissue laxity (defined as the ratio of displacement and gauge length relative to the first cycle of fatigue loading assessed at constant load throughout testing), at all loads and regions evaluated. Together, this study highlights the role of fatigue loading on tendon crimp properties as a function of load applied and region evaluated, and offers an additional structural mechanism for mechanical alterations that may lead to ultimate tendon failure. PMID:25773654

  20. Arthroscopically assisted percutaneous repair of fresh closed achilles tendon rupture by Kessler's suture.

    PubMed

    Tang, Kang-lai; Thermann, Hajo; Dai, Gang; Chen, Guang-xing; Guo, Lin; Yang, Liu

    2007-04-01

    Achilles tendon ruptures are difficult to repair, and the healing rate is low due to this structure's anatomic and physiological characteristics. It is essential to develop new techniques to increase the healing rate and decrease the rate of complications. To propose and evaluate a new percutaneous method of repairing fresh closed Achilles tendon ruptures by Kessler's suture under arthroscopy. Case series; Level of evidence, 4. Twenty patients were followed at least 12 months in this study. First, the torn ends of the Achilles tendon were debrided during arthroscopy. Then percutaneous repair of the Achilles tendon was performed using Kessler's suture by an inside-out technique. All cases were followed up for an average range of 21 months (range, 12-36 months). All patients were evaluated by clinical examination, magnetic resonance imaging, and the Lindholm scale. The torn ends were well aligned and sutured after the debridement under arthroscopy. According to the Lindholm scale, excellent results were seen in 15 cases and good in 5 cases. No patients had complications such as nerve injury, infection, or re-rupture at follow-up. Magnetic resonance imaging results showed that the ruptured Achilles tendons were repaired and remodeled very well in all patients. The present method is an effective surgical technique for repair of a closed rupture of the Achilles tendon. The short-term follow-up results were good, and recovery time was short. Few complications were found in our study cases.

  1. Shear load transfer in high and low stress tendons.

    PubMed

    Kondratko-Mittnacht, Jaclyn; Duenwald-Kuehl, Sarah; Lakes, Roderic; Vanderby, Ray

    2015-05-01

    Tendon is an integral part of joint movement and stability, as it functions to transmit load from muscle to bone. It has an anisotropic, fibrous hierarchical structure that is generally loaded in the direction of its fibers/fascicles. Internal load distributions are altered when joint motion rotates an insertion site or when local damage disrupts fibers/fascicles, potentially causing inter-fiber (or inter-fascicular) shear. Tendons with different microstructures (helical versus linear) may redistribute loads differently. This study explored how shear redistributes axial loads in rat tail tendon (low stress tendons with linear microstructure) and porcine flexor tendon (high stress with helical microstructure) by creating lacerations on opposite sides of the tendon, ranging from about 20% to 60% of the tendon width, to create various magnitudes of shear. Differences in fascicular orientation were quantified using polarized light microscopy. Unexpectedly, both tendon types maintained about 20% of pre-laceration stress values after overlapping cuts of 60% of tendon width (no intact fibers end to end) suggesting that shear stress transfer can contribute more to overall tendon strength and stiffness than previously reported. All structural parameters for both tendon types decreased linearly with increasing laceration depth. The tail tendon had a more rapid decline in post-laceration elastic stress and modulus parameters as well as a more linear and less tightly packed fascicular structure, suggesting that positional tendons may be less well suited to redistribute loads via a shear mechanism. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Shear Load Transfer in High and Low Stress Tendons

    PubMed Central

    Kondratko-Mittnacht, Jaclyn; Duenwald-Kuehl, Sarah; Lakes, Roderic; Vanderby, Ray

    2016-01-01

    Background Tendon is an integral part of joint movement and stability, as it functions to transmit load from muscle to bone. It has an anisotropic, fibrous hierarchical structure that is generally loaded in the direction of its fibers/fascicles. Internal load distributions are altered when joint motion rotates an insertion site or when local damage disrupts fibers/fascicles, potentially causing inter-fiber (or inter-fascicular) shear. Tendons with different microstructure (helical versus linear) may redistribute loads differently. Method of Approach This study explored how shear redistributes axial loads in rat tail tendon (low stress tendons with linear microstructure) and porcine flexor tendon (high stress with helical microstructure) by creating lacerations on opposite sides of the tendon, ranging from about 20-60% of the tendon width, to create various magnitudes of shear. Differences in fascicular orientation were quantified using polarized light microscopy. Results and Conclusions Unexpectedly, both tendon types maintained about 20% of pre-laceration stress values after overlapping cuts of 60% of tendon width (no intact fibers end to end) suggesting that shear stress transfer can contribute more to overall tendon strength and stiffness than previously reported. All structural parameters for both tendon types decreased linearly with increasing laceration depth. The tail tendon had a more rapid decline in post-laceration elastic stress and modulus parameters as well as a more linear and less tightly packed fascicular structure, suggesting that positional tendons may be less well suited to redistribute loads via a shear mechanism. PMID:25700261

  3. Proteomic differences between native and tissue-engineered tendon and ligament.

    PubMed

    Kharaz, Yalda A; Tew, Simon R; Peffers, Mandy; Canty-Laird, Elizabeth G; Comerford, Eithne

    2016-05-01

    Tendons and ligaments (T/Ls) play key roles in the musculoskeletal system, but they are susceptible to traumatic or age-related rupture, leading to severe morbidity as well as increased susceptibility to degenerative joint diseases such as osteoarthritis. Tissue engineering represents an attractive therapeutic approach to treating T/L injury but it is hampered by our poor understanding of the defining characteristics of the two tissues. The present study aimed to determine differences in the proteomic profile between native T/Ls and tissue engineered (TE) T/L constructs. The canine long digital extensor tendon and anterior cruciate ligament were analyzed along with 3D TE fibrin-based constructs created from their cells. Native tendon and ligament differed in their content of key structural proteins, with the ligament being more abundant in fibrocartilaginous proteins. 3D T/L TE constructs contained less extracellular matrix (ECM) proteins and had a greater proportion of cellular-associated proteins than native tissue, corresponding to their low collagen and high DNA content. Constructs were able to recapitulate native T/L tissue characteristics particularly with regard to ECM proteins. However, 3D T/L TE constructs had similar ECM and cellular protein compositions indicating that cell source may not be an important factor for T/L tissue engineering. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Decorin and biglycan are necessary for maintaining collagen fibril structure, fiber realignment, and mechanical properties of mature tendons.

    PubMed

    Robinson, Kelsey A; Sun, Mei; Barnum, Carrie E; Weiss, Stephanie N; Huegel, Julianne; Shetye, Snehal S; Lin, Linda; Saez, Daniel; Adams, Sheila M; Iozzo, Renato V; Soslowsky, Louis J; Birk, David E

    2017-12-01

    The small leucine-rich proteoglycans (SLRPs), decorin and biglycan, are key regulators of collagen fibril and matrix assembly. The goal of this work was to elucidate the roles of decorin and biglycan in tendon homeostasis. Our central hypothesis is that decorin and biglycan expression in the mature tendon would be critical for the maintenance of the structural and mechanical properties of healthy tendons. Defining the function(s) of these SLRPs in tendon homeostasis requires that effects in the mature tendon be isolated from their influence on development. Thus, we generated an inducible knockout mouse model that permits genetic ablation of decorin and biglycan expression in the mature tendon, while maintaining normal expression during development. Decorin and biglycan expression were knocked out in the mature patellar tendon with the subsequent turnover of endogenous SLRPs deposited prior to induction. The acute absence of SLRP expression was associated with changes in fibril structure with a general shift to larger diameter fibrils in the compound knockout tendons, together with fibril diameter heterogeneity. In addition, tendon mechanical properties were altered. Compared to wild-type controls, acute ablation of both genes resulted in failure of the tendon at lower loads, decreased stiffness, a trend towards decreased dynamic modulus, as well as a significant increase in percent relaxation and tissue viscosity. Collagen fiber realignment was also increased with a delayed and slower in response to load in the absence of expression. These structural and functional changes in response to an acute loss of decorin and biglycan expression in the mature tendon demonstrate a significant role for these SLRPs in adult tendon homeostasis. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. How Obesity Affects Tendons?

    PubMed

    Abate, Michele; Salini, Vincenzo; Andia, Isabel

    Several epidemiological and clinical observations have definitely demonstrated that obesity has harmful effects on tendons. The pathogenesis of tendon damage is multi-factorial. In addition to overload, attributable to the increased body weight, which significantly affects load-bearing tendons, systemic factors play a relevant role. Several bioactive peptides (chemerin, leptin, adiponectin and others) are released by adipocytes, and influence tendon structure by means of negative activities on mesenchymal cells. The ensuing systemic state of chronic, sub-clinic, low-grade inflammation can damage tendon structure. Metabolic disorders (diabetes, impaired glucose tolerance, and dislipidemia), frequently associated with visceral adiposity, are concurrent pathogenetic factors. Indeed, high glucose levels increase the formation of Advanced Glycation End-products, which in turn form stable covalent cross-links within collagen fibers, modifying their structure and functionality.Sport activities, so useful for preventing important cardiovascular complications, may be detrimental for tendons if they are submitted to intense acute or chronic overload. Therefore, two caution rules are mandatory: first, to engage in personalized soft training program, and secondly to follow regular check-up for tendon pathology.

  6. New Imaging Methods for Non-invasive Assessment of Mechanical, Structural, and Biochemical Properties of Human Achilles Tendon: A Mini Review

    PubMed Central

    Fouré, Alexandre

    2016-01-01

    The mechanical properties of tendon play a fundamental role to passively transmit forces from muscle to bone, withstand sudden stretches, and act as a mechanical buffer allowing the muscle to work more efficiently. The use of non-invasive imaging methods for the assessment of human tendon's mechanical, structural, and biochemical properties in vivo is relatively young in sports medicine, clinical practice, and basic science. Non-invasive assessment of the tendon properties may enhance the diagnosis of tendon injury and the characterization of recovery treatments. While ultrasonographic imaging is the most popular tool to assess the tendon's structural and indirectly, mechanical properties, ultrasonographic elastography, and ultra-high field magnetic resonance imaging (UHF MRI) have recently emerged as potentially powerful techniques to explore tendon tissues. This paper highlights some methodological cautions associated with conventional ultrasonography and perspectives for in vivo human Achilles tendon assessment using ultrasonographic elastography and UHF MRI. PMID:27512376

  7. Presence of Bacteria in Spontaneous Achilles Tendon Ruptures.

    PubMed

    Rolf, Christer G; Fu, Sai-Chuen; Hopkins, Chelsea; Luan, Ju; Ip, Margaret; Yung, Shu-Hang; Friman, Göran; Qin, Ling; Chan, Kai-Ming

    2017-07-01

    The structural pathology of Achilles tendon (AT) ruptures resembles tendinopathy, but the causes remain unknown. Recently, a number of diseases were found to be attributed to bacterial infections, resulting in low-grade inflammation and progressive matrix disturbance. The authors speculate that spontaneous AT ruptures may also be influenced by the presence of bacteria. Bacteria are present in ruptured ATs but not in healthy tendons. Cross-sectional study; Level of evidence, 3. Patients with spontaneous AT ruptures and patients undergoing anterior cruciate ligament (ACL) reconstruction were recruited for this study. During AT surgical repair, excised tendinopathic tissue was collected, and healthy tendon samples were obtained as controls from hamstring tendon grafts used in ACL reconstruction. Half of every sample was reserved for DNA extraction and the other half for histology. Polymerase chain reaction (PCR) was conducted using 16S rRNA gene universal primers, and the PCR products were sequenced for the identification of bacterial species. A histological examination was performed to compare tendinopathic changes in the case and control samples. Five of 20 AT rupture samples were positive for the presence of bacterial DNA, while none of the 23 hamstring tendon samples were positive. Sterile operating and experimental conditions and tests on samples, controlling for harvesting and processing procedures, ruled out the chance of postoperative bacterial contamination. The species identified predominantly belonged to the Staphylococcus genus. AT rupture samples exhibited histopathological features characteristic of tendinopathy, and most healthy hamstring tendon samples displayed normal tendon features. There were no apparent differences in histopathology between the bacterial DNA-positive and bacterial DNA-negative AT rupture samples. The authors have demonstrated the presence of bacterial DNA in ruptured AT samples. It may suggest the potential involvement of bacteria in spontaneous AT ruptures.

  8. Does the adolescent patellar tendon respond to 5 days of cumulative load during a volleyball tournament?

    PubMed

    van Ark, M; Docking, S I; van den Akker-Scheek, I; Rudavsky, A; Rio, E; Zwerver, J; Cook, J L

    2016-02-01

    Patellar tendinopathy (jumper's knee) has a high prevalence in jumping athletes. Excessive load on the patellar tendon through high volumes of training and competition is an important risk factor. Structural changes in the tendon are related to a higher risk of developing patellar tendinopathy. The critical tendon load that affects tendon structure is unknown. The aim of this study was to investigate patellar tendon structure on each day of a 5-day volleyball tournament in an adolescent population (16-18 years). The right patellar tendon of 41 players in the Australian Volleyball Schools Cup was scanned with ultrasound tissue characterization (UTC) on every day of the tournament (Monday to Friday). UTC can quantify structure of a tendon into four echo types based on the stability of the echo pattern. Generalized estimating equations (GEE) were used to test for change of echo type I and II over the tournament days. Participants played between eight and nine matches during the tournament. GEE analysis showed no significant change of echo type percentages of echo type I (Wald chi-square = 4.603, d.f. = 4, P = 0.331) and echo type II (Wald chi-square = 6.070, d.f. = 4, P = 0.194) over time. This study shows that patellar tendon structure of 16-18-year-old volleyball players is not affected during 5 days of cumulative loading during a volleyball tournament. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  9. Synthesis, development, characterization and effectiveness of bovine pure platelet gel-collagen-polydioxanone bioactive graft on tendon healing

    PubMed Central

    Moshiri, Ali; Oryan, Ahmad; Meimandi-Parizi, Abdolhamid

    2015-01-01

    Bovine platelet gel (BPG) is an accessible and cost-effective source of growth factors which may have a value in tendon regenerative medicine. We produced a collagen implant (CI) as a tendon proper, covered it with polydioxanone (PDS) sheath to simulate paratenon and finally embedded the BPG as an active source of growth factor within the bioimplant to test whether BPG would be able to accelerate and enhance tendon regeneration and repair. After in vitro characterization of the bioactive grafts, the grafts were implanted in rabbit large tendon defect model. Untreated tendons and tendons treated with either CI or CI-PDS were served as controls for the CI-PDS-BPG. The animals were investigated clinically, ultrasonographically and haematologically for 120 days. After euthanasia, dry matter content, water uptake and delivery characteristics and also gross morphological, histopathological and scanning electron microscopic features of the healing tendons were assessed. In vitro, the activated platelets in the scaffold, released their growth factors significantly more than the controls. BPG also increased cell viability, and enhanced cellular differentiation, maturation and proliferation inside the CI-PDS compared with the controls. In vivo, the BPG modulated inflammation, increased quality and rate of fibroplasia and produced a remodelled tendon that had significantly higher collagen content and superior collagen fibril and fibre differentiation than controls. Treatment also significantly improved tendon water uptake and delivery characteristics, animals’ serum PDGF level, CI-PDS biocompatibility and biodegradability and reduced peritendinous adhesions, muscle fibrosis and atrophy. BPG was effective on tendon healing and CI-PDS-BPG may be a valuable bioscaffold in tendon reconstructive surgery. PMID:25702535

  10. Anatomy of the Adductor Magnus Origin

    PubMed Central

    Obey, Mitchel R.; Broski, Stephen M.; Spinner, Robert J.; Collins, Mark S.; Krych, Aaron J.

    2016-01-01

    Background: The adductor magnus (AM) has historically been a potential source of confusion in patients with suspected proximal hamstring avulsion injuries. Purpose: To investigate the anatomic characteristics of the AM, including its osseous origin, anatomic dimensions, and relationship to the proximal hamstring tendons. Study Design: Descriptive laboratory study. Methods: Dissection of the AM origin was performed in 11 (8 cadavers) fresh-frozen hip-to-foot cadaveric hemipelvis specimens. The gross anatomy and architecture of the proximal hamstring and AM tendons were studied. After dissecting the hamstring tendons away from their origin, the dimension, shape, and orientation of the tendon footprints on the ischial tuberosity were determined. Results: The AM was identified in all cadaveric specimens. The mean tendon thickness (anterior to posterior [AP]) was 5.7 ± 2.9 mm. The mean tendon width (medial to lateral [ML]) was 7.1 ± 2.2 mm. The mean tendon length was 13.1 ± 8.7 cm. The mean footprint height (AP dimension) was 12.1 ± 2.9 mm, and mean footprint width (ML dimension) was 17.3 ± 7.1 mm. The mean distance between the AM footprint and the most medial aspect of the conjoint tendon footprint was 8.5 ± 4.2 mm. Tendon measurements demonstrated a considerable degree of both intra- and interspecimen variability. Conclusion: The AM tendon is consistently present just medial to the conjoint tendon at the ischial tuberosity, representing the lateral-most portion of the AM muscle. This study found wide variation in the dimensional characteristics of the AM tendon between specimens. Its shape and location can mimic the appearance of an intact hamstring (conjoint or semimembranosus) tendon intraoperatively or on diagnostic imaging, potentially misleading surgeons and radiologists. Therefore, detailed knowledge of the AM tendon anatomy, footprint anatomy, and its relationship to the hamstring muscle complex is paramount when planning surgical approach and technique. Clinical Relevance: The reported data may aid surgeons in more accurate recognition, diagnosis, and repair of proximal hamstring avulsion injuries. PMID:26798764

  11. FROM ACUTE ACHILLES TENDON RUPTURE TO RETURN TO PLAY - A CASE REPORT EVALUATING RECOVERY OF TENDON STRUCTURE, MECHANICAL PROPERTIES, CLINICAL AND FUNCTIONAL OUTCOMES.

    PubMed

    Zellers, Jennifer A; Cortes, Daniel H; Silbernagel, Karin Grävare

    2016-12-01

    Achilles tendon rupture results in significant functional deficits regardless of treatment strategy (surgical versus non-surgical intervention). Recovery post-rupture is highly variable, making comprehensive patient assessment critical. Assessment tools may change along the course of recovery as the patient progresses - for instance, moving from a seated heel-rise to standing heel-rise to jump testing. However, tools that serve as biomarkers for early recovery may be particularly useful in informing clinical decision-making. The purpose of this case report was to describe the progress of a young, athletic individual following Achilles tendon rupture managed non-surgically, using patient reported and functional performance outcome measures and comprehensively evaluating Achilles tendon structure and function incorporating a novel imaging technique (cSWE). The subject is a 26 year-old, female basketball coach who sustained an Achilles tendon rupture and was managed non-surgically. The subject was able to steadily progress using a gradual tendon loading treatment approach well-supported by the literature. Multiple evaluative techniques including the addition of diagnostic ultrasound imaging and continuous shear wave elastography (cSWE) to standard clinical tests and measures were used to assess patient-reported symptoms, tendon structure, and tendon functional performance. Five assessments were performed over the course of 2-14 months post-rupture. By the 14-month follow-up, the subject had achieved full self-reported function. Tendon structural and mechanical properties showed similar shear modulus by 14 months, however, viscosity continued to be lower and tendon length longer on the ruptured side. Functional performance, evidenced by the heel-rise test and jump tests, also showed a positive trajectory, however, deficits of 12-28% remained between ruptured and non-ruptured sides at 14 months. This case report outlines comprehensive outcomes assessment in an athletic individual following non-surgically managed Achilles tendon rupture using a wide variety of tools that capture different aspects of tendon health. Interestingly, the course of recovery of patient symptoms, functional performance, and tendon structure do not occur in the same time frame. Therefore, it is important to assess patient outcomes using multiple outcome measures encompassing different aspects of patient performance to ensure the patient is progressing steadily with rehabilitation. Level 4.

  12. Specialisation of extracellular matrix for function in tendons and ligaments

    PubMed Central

    Birch, Helen L.; Thorpe, Chavaunne T.; Rumian, Adam P.

    2013-01-01

    Summary Tendons and ligaments are similar structures in terms of their composition, organisation and mechanical properties. The distinction between them stems from their anatomical location; tendons form a link between muscle and bone while ligaments link bones to bones. A range of overlapping functions can be assigned to tendon and ligaments and each structure has specific mechanical properties which appear to be suited for particular in vivo function. The extracellular matrix in tendon and ligament varies in accordance with function, providing appropriate mechanical properties. The most useful framework in which to consider extracellular matrix differences therefore is that of function rather than anatomical location. In this review we discuss what is known about the relationship between functional requirements, structural properties from molecular to gross level, cellular gene expression and matrix turnover. The relevance of this information is considered by reviewing clinical aspects of tendon and ligament repair and reconstructive procedures. PMID:23885341

  13. Structure-mechanics relationships in mineralized tendons.

    PubMed

    Spiesz, Ewa M; Zysset, Philippe K

    2015-12-01

    In this paper, we review the hierarchical structure and the resulting elastic properties of mineralized tendons as obtained by various multiscale experimental and computational methods spanning from nano- to macroscale. The mechanical properties of mineralized collagen fibres are important to understand the mechanics of hard tissues constituted by complex arrangements of these fibres, like in human lamellar bone. The uniaxial mineralized collagen fibre array naturally occurring in avian tendons is a well studied model tissue for investigating various stages of tissue mineralization and the corresponding elastic properties. Some avian tendons mineralize with maturation, which results in a graded structure containing two zones of distinct morphology, circumferential and interstitial. These zones exhibit different amounts of mineral, collagen, pores and a different mineral distribution between collagen fibrillar and extrafibrillar space that lead to distinct elastic properties. Mineralized tendon cells have two phenotypes: elongated tenocytes placed between fibres in the circumferential zone and cuboidal cells with lower aspect ratios in the interstitial zone. Interestingly some regions of avian tendons seem to be predestined to mineralization, which is exhibited as specific collagen cross-linking patterns as well as distribution of minor tendon constituents (like proteoglycans) and loss of collagen crimp. Results of investigations in naturally mineralizing avian tendons may be useful in understanding the pathological mineralization occurring in some human tendons. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Definition and Reliability Assessment of Elementary Ultrasonographic Findings in Calcium Pyrophosphate Deposition Disease: A Study by the OMERACT Calcium Pyrophosphate Deposition Disease Ultrasound Subtask Force.

    PubMed

    Filippou, Georgios; Scirè, Carlo A; Damjanov, Nemanja; Adinolfi, Antonella; Carrara, Greta; Picerno, Valentina; Toscano, Carmela; Bruyn, George A; D'Agostino, Maria Antonietta; Delle Sedie, Andrea; Filippucci, Emilio; Gutierrez, Marwin; Micu, Mihaela; Möller, Ingrid; Naredo, Esperanza; Pineda, Carlos; Porta, Francesco; Schmidt, Wolfgang A; Terslev, Lene; Vlad, Violeta; Zufferey, Pascal; Iagnocco, Annamaria

    2017-11-01

    To define the ultrasonographic characteristics of calcium pyrophosphate crystal (CPP) deposits in joints and periarticular tissues and to evaluate the intra- and interobserver reliability of expert ultrasonographers in the assessment of CPP deposition disease (CPPD) according to the new definitions. After a systematic literature review, a Delphi survey was circulated among a group of expert ultrasonographers, who were members of the CPPD Ultrasound (US) Outcome Measures in Rheumatology (OMERACT) subtask force, to obtain definitions of the US characteristics of CPPD at the level of fibrocartilage (FC), hyaline cartilage (HC), tendon, and synovial fluid (SF). Subsequently, the reliability of US in assessing CPPD at knee and wrist levels according to the agreed definitions was tested in static images and in patients with CPPD. Cohen's κ was used for statistical analysis. HC and FC of the knee yielded the highest interobserver κ values among all the structures examined, in both the Web-based (0.73 for HC and 0.58 for FC) and patient-based exercises (0.55 for the HC and 0.64 for the FC). Kappa values for the other structures were lower, ranging from 0.28 in tendons to 0.50 in SF in the static exercise and from 0.09 (proximal patellar tendon) to 0.27 (triangular FC of the wrist) in the patient-based exercise. The new OMERACT definitions for the US identification of CPPD proved to be reliable at the level of the HC and FC of the knee. Further studies are needed to better define the US characteristics of CPPD and optimize the scanning technique in other anatomical sites.

  15. Implantation of a Novel Biologic and Hybridized Tissue Engineered Bioimplant in Large Tendon Defect: An In Vivo Investigation

    PubMed Central

    Oryan, Ahmad; Moshiri, Ali; Parizi, Abdolhamid Meimandi

    2014-01-01

    Surgical reconstruction of large Achilles tendon defects is technically demanding. There is no standard method, and tissue engineering may be a valuable option. We investigated the effects of 3D collagen and collagen-polydioxanone sheath (PDS) implants on a large tendon defect model in rabbits. Ninety rabbits were divided into three groups: control, collagen, and collagen-PDS. In all groups, 2 cm of the left Achilles tendon were excised and discarded. A modified Kessler suture was applied to all injured tendons to retain the gap length. The control group received no graft, the treated groups were repaired using the collagen only or the collagen-PDS prostheses. The bioelectrical characteristics of the injured areas were measured at weekly intervals. The animals were euthanized at 60 days after the procedure. Gross, histopathological and ultrastructural morphology and biophysical characteristics of the injured and intact tendons were investigated. Another 90 pilot animals were also used to investigate the inflammatory response and mechanism of graft incorporation during tendon healing. The control tendons showed severe hyperemia and peritendinous adhesion, and the gastrocnemius muscle of the control animals showed severe atrophy and fibrosis, with a loose areolar connective tissue filling the injured area. The tendons receiving either collagen or collagen-PDS implants showed lower amounts of peritendinous adhesion, hyperemia and muscle atrophy, and a dense tendon filled the defect area. Compared to the control tendons, application of collagen and collagen-PDS implants significantly improved water uptake, water delivery, direct transitional electrical current and tissue resistance to direct transitional electrical current. Compared to the control tendons, both prostheses showed significantly increased diameter, density and alignment of the collagen fibrils and maturity of the tenoblasts at ultrastructure level. Both prostheses influenced favorably tendon healing compared to the control tendons, with no significant differences between collagen and collagen-PDS groups. Implantation of the 3D collagen and collagen-PDS implants accelerated the production of a new tendon in the defect area, and may become a valuable option in clinical practice. PMID:24004331

  16. A new non-metallic anchorage system for post-tensioning applications using CFRP tendons

    NASA Astrophysics Data System (ADS)

    Taha, Mahmoud Reda

    The objective of the work described in this thesis is to design, develop and test a new non-metallic anchorage system for post-tensioning applications using CFRP tendons. The use of a non-metallic anchorage system should eliminate corrosion and deterioration concerns in the anchorage zone. The development of a reliable non-metallic anchorage would provide an important contribution to this field of knowledge. The idea of the new anchorage is to hold the tendon through mechanical gripping. The anchorage consists of a barrel with a conical housing and four wedges. The anchorage components are made of ultra high performance concrete (UHPC) specially developed for the anchorage. Sixteen concrete mixtures with different casting and curing regimes were examined to develop four UHPC mixtures with compressive strengths in excess of 200 MPa. The UHPC mixtures showed very dense microstructures with some unique characteristics. To enhance the fracture toughness of the newly developed UHPC, analytical and experimental analyses were performed. Using 3 mm chopped carbon fibres, a significant increase in the fracture toughness of UHPC was achieved. The non-metallic anchorage was developed with the UHPC with enhanced fracture toughness. The barrel required careful wrapping with CFRP sheets to provide the confinement required to utilize the strength and toughness of the UHPC. Thirty-three anchorages were tested under both static and dynamic loading conditions. The non-metallic anchorage showed excellent mechanical performance and fulfilled the different requirements of a post-tensioning anchorage system. The development of the new non-metallic anchorage will widen the inclusion of CFRP tendons in post-tensioned concrete/masonry structures. The new system will offer the opportunity to exploit CFRP tendons effectively creating an innovative generation of corrosion-free, smart structures.

  17. Platelet-Rich Plasma Injection With Arthroscopic Acromioplasty for Chronic Rotator Cuff Tendinopathy: A Randomized Controlled Trial.

    PubMed

    Carr, Andrew J; Murphy, Richard; Dakin, Stephanie G; Rombach, Ines; Wheway, Kim; Watkins, Bridget; Franklin, Sarah L

    2015-12-01

    Platelet-rich plasma (PRP) has been proposed to augment tendon healing through improving tissue structure during the initial repair phase. To investigate both the clinical and tissue effects of the coapplication of PRP injection with arthroscopic acromioplasty (AA) in patients with chronic rotator cuff tendinopathy. Randomized controlled trial; Level of evidence, 1. The study comprised 60 randomized patients diagnosed with rotator cuff tendinopathy (55% women) aged between 35 and 75 years. Patients were randomized to AA alone or in combination with an injection of autologous PRP into the subacromial bursa (AA + PRP). Efficacy of treatment was assessed by analysis of patient-reported outcomes up to 2 years after treatment (Oxford Shoulder Score [OSS]) and by analysis of tendon biopsy specimens taken 12 weeks after treatment. There was no significant difference in the OSS between AA alone and AA + PRP at any time point in the study. From 12 weeks onward, there was a significant increase in the OSS for both groups compared with their baseline scores (P < .001). Bonar scoring determined no significant change in tissue structure with the coapplication of PRP compared with surgery alone. The number of blood vessels and tendon cellularity were significantly decreased in tissue biopsy specimens taken from PRP-treated patients. The expression of p53-positive apoptotic cells increased after AA + PRP but decreased after AA alone. Arthroscopic acromioplasty significantly improves long-term clinical outcomes up to 2 years. The coapplication of PRP did not affect clinical outcomes. PRP significantly alters the tissue characteristics in tendons after surgery with reduced cellularity and vascularity and increased levels of apoptosis. The coapplication of PRP did not improve clinical outcomes and may have potential deleterious effects on healing tendons. ISRCTN 10464365. © 2015 The Author(s).

  18. Effect of training and sudden detraining on the patellar tendon and its enthesis in rats

    PubMed Central

    2011-01-01

    Background Different conditions may alter tendon characteristics. Clinical evidence suggests that tendon injuries are more frequent in athletes that change type, intensity and duration of training. Aim of the study was the assessment of training and especially detraining on the patellar tendon (PT) and its enthesis. Methods 27 male adult Sprague-Dawley rats were divided into 3 groups: 20 rats were trained on a treadmill for 10 weeks. Of these, 10 rats were euthanized immediately after training (trained group), and 10 were caged without exercise for 4 weeks before being euthanized (de-trained group). The remaining 7 rats were used as controls (untrained rats). PT insertion, structure (collagen fiber organization and proteoglycan, PG, content), PT thickness, enthesis area, and subchondral bone volume at the enthesis were measured by histomorphometry and microtomography. Results Both PG content and collagen fiber organization were significantly lower in untrained and detrained animals than in trained ones (p < 0.05 and p < 0.0001). In the detrained group, fiber organization and PG content were worse than that of the untrained groups and the untrained group showed a significantly higher score than the detrained group (p < 0.05). In the trained group, the PT was significantly thicker than in untrained group (p < 0.05). No significant differences in the enthesis area and subchondral bone volume among the three groups were seen. Conclusions Moderate exercise exerts a protective effect on the PT structure while sudden discontinuation of physical activity has a negative effect on tendons. The present results suggest that after a period of sudden de-training (such as after an injury) physical activity should be restarted with caution and with appropriate rehabilitation programs. PMID:21247475

  19. Tendon allograft sterilized by peracetic acid/ethanol combined with gamma irradiation.

    PubMed

    Zhou, Mo; Zhang, Naili; Liu, Xiaoming; Li, Youchen; Zhang, Yumin; Wang, Xusheng; Li, Baoming; Li, Baoxing

    2014-07-01

    Research and clinical applications have demonstrated that the effects of tendon allografts are comparable to those of autografts when reconstructing injured tendons or ligaments, but allograft safety remains problematic. Sterilisation could eliminate or decrease the possibility of disease transmission, but current methods seldom achieve satisfactory sterilisation without affecting the mechanical properties of the tendon. Peracetic acid-ethanol in combination with low-dose gamma irradiation (PE-R) would inactivate potential deleterious microorganisms without affecting mechanical and biocompatible properties of tendon allograft. Controlled laboratory design. HIV, PPV, PRV and BVDV inactivation was evaluated. After verifying viral inactivation, the treated tendon allografts were characterised by optical microscopy, scanning electron microscopy and tensile testing, and the cytocompatibility was assessed with an MTT assay and by subcutaneous implantation. Effective and efficient inactivation of HIV, PPV, PRV and BVDV was observed. Histological structure and ultrastructure were unchanged in the treated tendon allograft, which also exhibited comparable biomechanical properties and good biocompatibility. The preliminary results confirmed our hypothesis and demonstrated that the PE-R tendon allograft has significant potential as an alternative to ligament/tendon reconstruction. Tendon allografts have been extensively used in ligament reconstruction and tendon repair. However, current sterilisation methods have various shortcomings, so PE-R has been proposed. This study suggests that PE-R tendon allograft has great potential as an alternative for ligament/tendon reconstruction. Sterilisation has been a great concern for tendon allografts. However, most sterilisation methods cannot inactivate viruses and bacteria without impairing the mechanical properties of the tendon allograft. Peracetic acid/ethanol with gamma irradiation can effectively inactivate viruses and bacteria. Meanwhile, tendon allografts sterilised by this method maintain their physiological tendon structure, biomechanical integrity and good compatibility.

  20. Conditioning of the Achilles tendon via ankle exercise improves correlations between sonographic measures of tendon thickness and body anthropometry.

    PubMed

    Wearing, Scott C; Grigg, Nicole L; Hooper, Sue L; Smeathers, James E

    2011-05-01

    Although conditioning is routinely used in mechanical tests of tendon in vitro, previous in vivo research evaluating the influence of body anthropometry on Achilles tendon thickness has not considered its potential effects on tendon structure. This study evaluated the relationship between Achilles tendon thickness and body anthropometry in healthy adults both before and after resistive ankle plantarflexion exercise. A convenience sample of 30 healthy male adults underwent sonographic examination of the Achilles tendon in addition to standard anthropometric measures of stature and body weight. A 10-5 MHz linear array transducer was used to acquire longitudinal sonograms of the Achilles tendon, 20 mm proximal to the tendon insertion. Participants then completed a series (90-100 repetitions) of conditioning exercises against an effective resistance between 100% and 150% body weight. Longitudinal sonograms were repeated immediately on completion of the exercise intervention, and anteroposterior Achilles tendon thickness was determined. Achilles tendon thickness was significantly reduced immediately following conditioning exercise (t = 9.71, P < 0.001), resulting in an average transverse strain of -18.8%. In contrast to preexercise measures, Achilles tendon thickness was significantly correlated with body weight (r = 0.72, P < 0.001) and to a lesser extent height (r = 0.45, P = 0.01) and body mass index (r = 0.63, P < 0.001) after exercise. Conditioning of the Achilles tendon via resistive ankle exercises induces alterations in tendon structure that substantially improve correlations between Achilles tendon thickness and body anthropometry. It is recommended that conditioning exercises, which standardize the load history of tendon, are employed before measurements of sonographic tendon thickness in vivo.

  1. Quadriceps tendon autograft for arthroscopic knee ligament reconstruction: use it now, use it often.

    PubMed

    Sheean, Andrew J; Musahl, Volker; Slone, Harris S; Xerogeanes, John W; Milinkovic, Danko; Fink, Christian; Hoser, Christian

    2018-04-28

    Traditional bone-patellar tendon-bone and hamstring tendon ACL grafts are not without limitations. A growing body of anatomic, biomechanical and clinical data has demonstrated the utility of quadriceps tendon autograft in arthroscopic knee ligament reconstruction. The quadriceps tendon autograft provides a robust volume of tissue that can be reliably harvested, mitigating the likelihood of variably sized grafts and obviating the necessity of allograft augmentation. Modern, minimally invasive harvest techniques offer the advantages of low rates of donor site morbidity and residual extensor mechanism strength deficits. New data suggest that quadriceps tendon autograft may possess superior biomechanical characteristics when compared with bone-patella tendon-bone (BPTB) autograft. However, there have been very few direct, prospective comparisons between the clinical outcomes associated with quadriceps tendon autograft and other autograft options (eg, hamstring tendon and bone-patellar tendon-bone). Nevertheless, quadriceps tendon autograft should be one of the primary options in any knee surgeon's armamentarium. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  2. The role of the non-collagenous matrix in tendon function.

    PubMed

    Thorpe, Chavaunne T; Birch, Helen L; Clegg, Peter D; Screen, Hazel R C

    2013-08-01

    Tendon consists of highly ordered type I collagen molecules that are grouped together to form subunits of increasing diameter. At each hierarchical level, the type I collagen is interspersed with a predominantly non-collagenous matrix (NCM) (Connect. Tissue Res., 6, 1978, 11). Whilst many studies have investigated the structure, organization and function of the collagenous matrix within tendon, relatively few have studied the non-collagenous components. However, there is a growing body of research suggesting the NCM plays an important role within tendon; adaptations to this matrix may confer the specific properties required by tendons with different functions. Furthermore, age-related alterations to non-collagenous proteins have been identified, which may affect tendon resistance to injury. This review focuses on the NCM within the tensional region of developing and mature tendon, discussing the current knowledge and identifying areas that require further study to fully understand structure-function relationships within tendon. This information will aid in the development of appropriate techniques for tendon injury prevention and treatment. © 2013 The Authors. International Journal of Experimental Pathology © 2013 International Journal of Experimental Pathology.

  3. An overview of structure, mechanical properties, and treatment for age-related tendinopathy.

    PubMed

    Zhou, B; Zhou, Y; Tang, K

    2014-04-01

    Tendons transfer tensile loads from muscle to bone, which enable joint motions and stabilize joints. Tendons sustain large mechanical loads in vivo and as a result, tendons were frequently injured. Aging has been confirmed as a predisposing factor of tendinopathy and bad recovery quality following tendon repair. Current treatment methods are generally not effective and involve either symptomatic relief with non-steroidal antiinflammatory drugs and physical therapy or surgery when conservative treatments failed. The limitation in treatment options is due to our incomplete knowledge of age-related tendinopathy. Studies over the past decades have uncovered a number of important mechanical and cellular changes of aging tendon. However, the basis of aging as a major risk factor for tendon injury and impaired tendon healing remained poorly understood. The objectives of this review are to provide an overview of the current knowledge about the aging-associated changes of structure, mechanical properties and treatment in tendon and highlight causes and therapies for age-related tendinopathy.

  4. Australian football players' Achilles tendons respond to game loads within 2 days: an ultrasound tissue characterisation (UTC) study.

    PubMed

    Rosengarten, Samuel D; Cook, Jill L; Bryant, Adam L; Cordy, Justin T; Daffy, John; Docking, Sean I

    2015-02-01

    The Achilles tendon is a tissue that responds to mechanical loads at a molecular and cellular level. In vitro and in vivo studies have shown that the expression of anabolic and/or catabolic proteins can change within hours of loading and return to baseline levels within 72 h. These biochemical changes have not been correlated with changes in whole tendon structure on imaging. We examined the nature and temporal sequence of changes in Achilles tendon structure in response to competitive game loads in elite Australian football players. Elite male Australian football players with no history of Achilles tendinopathy were recruited. Achilles tendon structure was quantified using ultrasound tissue characterisation (UTC) imaging, a valid and reliable measure of intratendinous structure, the day prior to the match (day 0), and then reimaged on days 1, 2 and 4 postgame. Of the 18 participants eligible for this study, 12 had no history of tendinopathy (NORM) and 6 had a history of patellar or hamstring tendinopathy (TEN). Differences in baseline UTC echopattern were observed between the NORM and TEN groups, with the Achilles of the TEN group exhibiting altered UTC echopattern, consistent with a slightly disorganised tendon structure. In the NORM group, a significant reduction in echo-type I (normal tendon structure) was seen on day 2 (p=0.012) that returned to baseline on day 4. There was a transient change in UTC echopattern in the Achilles tendon as a result of an Australian football game in individuals without a history of lower limb tendinopathy. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  5. Achilles tendon structure improves on UTC imaging over a 5-month pre-season in elite Australian football players.

    PubMed

    Docking, S I; Rosengarten, S D; Cook, J

    2016-05-01

    Pre-season injuries are common and may be due to a reintroduction of training loads. Tendons are sensitive to changes in load, making them vulnerable to injury in the pre-season. This study investigated changes in Achilles tendon structure on ultrasound tissue characterization (UTC) over the course of a 5-month pre-season in elite male Australian football players. Eighteen elite male Australian football players with no history of Achilles tendinopathy and normal Achilles tendons were recruited. The left Achilles tendon was scanned with UTC to quantify the stability of the echopattern. Participants were scanned at the start and completion of a 5-month pre-season. Fifteen players remained asymptomatic over the course of the pre-season. All four echo-types were significantly different at the end of the pre-season, with the overall echopattern suggesting an improvement in Achilles tendon structure. Three of the 18 participants developed Achilles tendon pain that coincided with a change in the UTC echopattern. This study demonstrates that the UTC echopattern of the Achilles tendon improves over a 5-month pre-season training period, representing increased fibrillar alignment. However, further investigation is needed to elucidate with this alteration in the UTC echopattern results in improved tendon resilience and load capacity. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. High-resolution study of the 3D collagen fibrillary matrix of Achilles tendons without tissue labelling and dehydrating.

    PubMed

    Wu, Jian-Ping; Swift, Benjamin John; Becker, Thomas; Squelch, Andrew; Wang, Allan; Zheng, Yong-Chang; Zhao, Xuelin; Xu, Jiake; Xue, Wei; Zheng, Minghao; Lloyd, David; Kirk, Thomas Brett

    2017-06-01

    Knowledge of the collagen structure of an Achilles tendon is critical to comprehend the physiology, biomechanics, homeostasis and remodelling of the tissue. Despite intensive studies, there are still uncertainties regarding the microstructure. The majority of studies have examined the longitudinally arranged collagen fibrils as they are primarily attributed to the principal tensile strength of the tendon. Few studies have considered the structural integrity of the entire three-dimensional (3D) collagen meshwork, and how the longitudinal collagen fibrils are integrated as a strong unit in a 3D domain to provide the tendons with the essential tensile properties. Using second harmonic generation imaging, a 3D imaging technique was developed and used to study the 3D collagen matrix in the midportion of Achilles tendons without tissue labelling and dehydration. Therefore, the 3D collagen structure is presented in a condition closely representative of the in vivo status. Atomic force microscopy studies have confirmed that second harmonic generation reveals the internal collagen matrix of tendons in 3D at a fibril level. Achilles tendons primarily contain longitudinal collagen fibrils that braid spatially into a dense rope-like collagen meshwork and are encapsulated or wound tightly by the oblique collagen fibrils emanating from the epitenon region. The arrangement of the collagen fibrils provides the longitudinal fibrils with essential structural integrity and endows the tendon with the unique mechanical function for withstanding tensile stresses. A novel 3D microscopic method has been developed to examine the 3D collagen microstructure of tendons without tissue dehydrating and labelling. The study also provides new knowledge about the collagen microstructure in an Achilles tendon, which enables understanding of the function of the tissue. The knowledge may be important for applying surgical and tissue engineering techniques to tendon reconstruction. © 2017 The Authors Journal of Microscopy © 2017 Royal Microscopical Society.

  7. Hybrid system of unbonded post-tensioned CLT panels and light-frame wood shear walls

    Treesearch

    T. Ho; T. Dao; S. Aaleti; J. van de Lindt; Douglas Rammer

    2016-01-01

    Cross-laminated timber (CLT) is a relatively new type of massive timber system that has shown to possess excellent mechanical properties and structural behavior in building construction. When post-tensioned with high-strength tendons, CLT panels perform well under cyclic loadings because of two key characteristics: their rocking behavior and self-centering capacity....

  8. Achilles tendon: US examination

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fornage, B.D.

    Real-time ultrasonography (US) using linear-array probes and a stand-off pad as a ''waterpath'' was performed to evaluate the Achilles tendon in 67 patients (including 24 athletes) believed to have acute or chronic traumatic or inflammatory pathologic conditions. Tendons in 23 patients appeared normal on US scans. The 44 abnormal tendons comprised five complete and four partial ruptures, seven instances of postoperative change, and 28 cases of tendonitis. US depiction of the inner structure of the tendon resulted in the diagnosis of focal abnormalities, including partial ruptures, nodules, and calcifications. Tendonitis was characterized by enlargement and decreased echogenicity of the tendon.more » The normal US appearance of the Achilles tendon is described.« less

  9. Diagnostic value of tendon thickness and structure in the sonographic diagnosis of supraspinatus tendinopathy: room for a two-step approach.

    PubMed

    Arend, Carlos Frederico; Arend, Ana Amalia; da Silva, Tiago Rodrigues

    2014-06-01

    The aim of our study was to systematically compare different methodologies to establish an evidence-based approach based on tendon thickness and structure for sonographic diagnosis of supraspinatus tendinopathy when compared to MRI. US was obtained from 164 symptomatic patients with supraspinatus tendinopathy detected at MRI and 42 asymptomatic controls with normal MRI. Diagnostic yield was calculated for either maximal supraspinatus tendon thickness (MSTT) and tendon structure as isolated criteria and using different combinations of parallel and sequential testing at US. Chi-squared tests were performed to assess sensitivity, specificity, and accuracy of different diagnostic approaches. Mean MSTT was 6.68 mm in symptomatic patients and 5.61 mm in asymptomatic controls (P<.05). When used as an isolated criterion, MSTT>6.0mm provided best results for accuracy (93.7%) when compared to other measurements of tendon thickness. Also as an isolated criterion, abnormal tendon structure (ATS) yielded 93.2% accuracy for diagnosis. The best overall yield was obtained by both parallel and sequential testing using either MSTT>6.0mm or ATS as diagnostic criteria at no particular order, which provided 99.0% accuracy, 100% sensitivity, and 95.2% specificity. Among these parallel and sequential tests that provided best overall yield, additional analysis revealed that sequential testing first evaluating tendon structure required assessment of 258 criteria (vs. 261 for sequential testing first evaluating tendon thickness and 412 for parallel testing) and demanded a mean of 16.1s to assess diagnostic criteria and reach the diagnosis (vs. 43.3s for sequential testing first evaluating tendon thickness and 47.4s for parallel testing). We found that using either MSTT>6.0mm or ATS as diagnostic criteria for both parallel and sequential testing provides the best overall yield for sonographic diagnosis of supraspinatus tendinopathy when compared to MRI. Among these strategies, a two-step sequential approach first assessing tendon structure was advantageous because it required a lower number of criteria to be assessed and demanded less time to assess diagnostic criteria and reach the diagnosis. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  10. Using the zebrafish to understand tendon development and repair

    PubMed Central

    Chen, Jessica W.; Galloway, Jenna L.

    2017-01-01

    Tendons are important components of our musculoskeletal system. Injuries to these tissues are very common, resulting from occupational-related injuries, sports-related trauma, and age-related degeneration. Unfortunately, there are few treatment options, and current therapies rarely restore injured tendons to their original function. An improved understanding of the pathways regulating their development and repair would have significant impact in stimulating the formulation of regenerative-based approaches for tendon injury. The zebrafish provides an ideal system in which to perform genetic and chemical screens to identify new pathways involved in tendon biology. Until recently, there had been few descriptions of tendons and ligaments in the zebrafish and their similarity to mammalian tendon tissues. In this chapter, we describe the development of the zebrafish tendon and ligament tissues in the context of their gene expression, structure, and interactions with neighboring musculoskeletal tissues. We highlight the similarities with tendon development in higher vertebrates, showing that the craniofacial tendons and ligaments in zebrafish morphologically, molecularly, and structurally resemble mammalian tendons and ligaments from embryonic to adult stages. We detail methods for fluorescent in situ hybridization and immunohistochemistry as an assay to examine morphological changes in the zebrafish musculoskeleton. Staining assays such as these could provide the foundation for screen-based approaches to identify new regulators of tendon development, morphogenesis, and repair. These discoveries would provide new targets and pathways to study in the context of regenerative medicine-based approaches to improve tendon healing. PMID:28129848

  11. Current Biomechanical Concepts for Rotator Cuff Repair

    PubMed Central

    2013-01-01

    For the past few decades, the repair of rotator cuff tears has evolved significantly with advances in arthroscopy techniques, suture anchors and instrumentation. From the biomechanical perspective, the focus in arthroscopic repair has been on increasing fixation strength and restoration of the footprint contact characteristics to provide early rehabilitation and improve healing. To accomplish these objectives, various repair strategies and construct configurations have been developed for rotator cuff repair with the understanding that many factors contribute to the structural integrity of the repaired construct. These include repaired rotator cuff tendon-footprint motion, increased tendon-footprint contact area and pressure, and tissue quality of tendon and bone. In addition, the healing response may be compromised by intrinsic factors such as decreased vascularity, hypoxia, and fibrocartilaginous changes or aforementioned extrinsic compression factors. Furthermore, it is well documented that torn rotator cuff muscles have a tendency to atrophy and become subject to fatty infiltration which may affect the longevity of the repair. Despite all the aforementioned factors, initial fixation strength is an essential consideration in optimizing rotator cuff repair. Therefore, numerous biomechanical studies have focused on elucidating the strongest devices, knots, and repair configurations to improve contact characteristics for rotator cuff repair. In this review, the biomechanical concepts behind current rotator cuff repair techniques will be reviewed and discussed. PMID:23730471

  12. Chronic Degeneration Leads to Poor Healing of Repaired Massive Rotator Cuff Tears in Rats.

    PubMed

    Killian, Megan L; Cavinatto, Leonardo M; Ward, Samuel R; Havlioglu, Necat; Thomopoulos, Stavros; Galatz, Leesa M

    2015-10-01

    Chronic rotator cuff tears present a clinical challenge, often with poor outcomes after surgical repair. Degenerative changes to the muscle, tendon, and bone are thought to hinder healing after surgical repair; additionally, the ability to overcome degenerative changes after surgical repair remains unclear. The purpose of this study was to evaluate healing outcomes of muscle, tendon, and bone after tendon repair in a model of chronic rotator cuff disease and to compare these outcomes to those of acute rotator cuff injuries and repair. The hypothesis was that degenerative rotator cuff changes associated with chronic multitendon tears and muscle unloading would lead to poor structural and mechanical outcomes after repair compared with acute injuries and repair. Controlled laboratory study. Chronic rotator cuff injuries, induced via detachment of the supraspinatus (SS) and infraspinatus (IS) tendons and injection of botulinum toxin A into the SS and IS muscle bellies, were created in the shoulders of rats. After 8 weeks of injury, tendons were surgically reattached to the humeral head, and an acute, dual-tendon injury and repair was performed on the contralateral side. After 8 weeks of healing, muscles were examined histologically, and tendon-to-bone samples were examined microscopically, histologically, and biomechanically and via micro-computed tomography. All repairs were intact at the time of dissection, with no evidence of gapping or ruptures. Tendon-to-bone healing after repair in our chronic injury model led to reduced bone quality and morphological disorganization at the repair site compared with acute injuries and repair. SS and IS muscles were atrophic at 8 weeks after repair of chronic injuries, indicating incomplete recovery after repair, whereas SS and IS muscles exhibited less atrophy and degeneration in the acute injury group at 8 weeks after repair. After chronic injuries and repair, humeral heads had decreased total mineral density and an altered trabecular structure, and the repair had decreased strength, stiffness, and toughness, compared with the acute injury and repair group. Chronic degenerative changes in rotator cuff muscles, tendons, and bone led to inferior healing characteristics after repair compared with acute injuries and repair. The changes were not reversible after repair in the time course studied, consistent with clinical impressions. High retear rates after rotator cuff repair are associated with tear size and chronicity. Understanding the mechanisms behind this association may allow for targeted tissue therapy for tissue degeneration that occurs in the setting of chronic tears. © 2015 The Author(s).

  13. Chronic Degeneration Leads to Poor Healing of Repaired Massive Rotator Cuff Tears in Rats

    PubMed Central

    Killian, Megan L.; Cavinatto, Leonardo M.; Ward, Samuel R.; Havlioglu, Necat; Thomopoulos, Stavros; Galatz, Leesa M.

    2016-01-01

    Background Chronic rotator cuff tears present a clinical challenge, often with poor outcomes after surgical repair. Degenerative changes to the muscle, tendon, and bone are thought to hinder healing after surgical repair; additionally, the ability to overcome degenerative changes after surgical repair remains unclear. Purpose/Hypothesis The purpose of this study was to evaluate healing outcomes of muscle, tendon, and bone after tendon repair in a model of chronic rotator cuff disease and to compare these outcomes to those of acute rotator cuff injuries and repair. The hypothesis was that degenerative rotator cuff changes associated with chronic multitendon tears and muscle unloading would lead to poor structural and mechanical outcomes after repair compared with acute injuries and repair. Study Design Controlled laboratory study. Methods Chronic rotator cuff injuries, induced via detachment of the supraspinatus (SS) and infraspinatus (IS) tendons and injection of botulinum toxin A into the SS and IS muscle bellies, were created in the shoulders of rats. After 8 weeks of injury, tendons were surgically reattached to the humeral head, and an acute, dual-tendon injury and repair was performed on the contralateral side. After 8 weeks of healing, muscles were examined histologically, and tendon-to-bone samples were examined microscopically, histologically, and biomechanically and via micro–computed tomography. Results All repairs were intact at the time of dissection, with no evidence of gapping or ruptures. Tendon-to-bone healing after repair in our chronic injury model led to reduced bone quality and morphological disorganization at the repair site compared with acute injuries and repair. SS and IS muscles were atrophic at 8 weeks after repair of chronic injuries, indicating incomplete recovery after repair, whereas SS and IS muscles exhibited less atrophy and degeneration in the acute injury group at 8 weeks after repair. After chronic injuries and repair, humeral heads had decreased total mineral density and an altered trabecular structure, and the repair had decreased strength, stiffness, and toughness, compared with the acute injury and repair group. Conclusion Chronic degenerative changes in rotator cuff muscles, tendons, and bone led to inferior healing characteristics after repair compared with acute injuries and repair. The changes were not reversible after repair in the time course studied, consistent with clinical impressions. Clinical Relevance High retear rates after rotator cuff repair are associated with tear size and chronicity. Understanding the mechanisms behind this association may allow for targeted tissue therapy for tissue degeneration that occurs in the setting of chronic tears. PMID:26297522

  14. Tissue Engineering Strategies for the Tendon/ligament-to-bone insertion

    PubMed Central

    Smith, Lester; Xia, Younan; Galatz, Leesa M.; Genin, Guy M.; Thomopoulos, Stavros

    2012-01-01

    Injuries to connective tissues are painful and disabling and result in costly medical expenses. These injuries often require re-attachment of an unmineralized connective tissue to bone. The uninjured tendon/ligament-to-bone insertion (enthesis) is a functionally graded material that exhibits a gradual transition from soft tissue (i.e., tendon or ligament) to hard tissue (i.e., mineralized bone) through a fibrocartilaginous transition region. This transition is believed to facilitate force transmission between the two dissimilar tissues by ameliorating potentially damaging interfacial stress concentrations. The transition region is impaired or lost upon tendon/ligament injury and is not regenerated following surgical repair or natural healing, exposing the tissue to risk of re-injury. The need to regenerate a robust tendon-to-bone insertion has led a number of tissue engineering repair strategies. This review treats the tendon-to-bone insertion site as a tissue structure whose primary role is mechanical and discusses current and emerging strategies for engineering the tendon/ligament-to-bone insertion in this context. The focus lies on strategies for producing mechanical structures that can guide and subsequently sustain a graded tissue structure and the associated cell populations. PMID:22185608

  15. Tendon regeneration in human and equine athletes: Ubi Sumus-Quo Vadimus (where are we and where are we going to)?

    PubMed

    Spaas, Jan H; Guest, Deborah J; Van de Walle, Gerlinde R

    2012-10-01

    Tendon injuries are one of the most common orthopaedic problems in both human and equine athletes. When a damaged tendon heals naturally, it loses a substantial part of the original strength and elasticity. Therefore, tendons recover structurally (reparation) but not functionally (regeneration) after conservative medical or surgical treatment. Since the structure and matrix composition of human and equine tendons share many similarities, the nature of tendon injuries are also strongly comparable in both species. Therefore, the evaluation of regenerative therapies in horses may have applications for future human medicine and vice versa. The current review focuses briefly on the physiology of human and equine tendon in order to better comprehend the modus operandi of this structure under pathophysiological circumstances. In addition, the reparative effects of conservative medical and surgical interventions are discussed concisely, and an extensive overview is given on the regenerative therapies that are currently being explored. For the latter, the results of equine clinical studies might prove invaluable for gaining additional insights into the treatment of human tendinopathies, since not all of these novel regenerative therapies have been evaluated in humans yet.

  16. Tissue-engineering strategies for the tendon/ligament-to-bone insertion.

    PubMed

    Smith, Lester; Xia, Younan; Galatz, Leesa M; Genin, Guy M; Thomopoulos, Stavros

    2012-01-01

    Injuries to connective tissues are painful and disabling and result in costly medical expenses. These injuries often require reattachment of an unmineralized connective tissue to bone. The uninjured tendon/ligament-to-bone insertion (enthesis) is a functionally graded material that exhibits a gradual transition from soft tissue (i.e., tendon or ligament) to hard tissue (i.e., mineralized bone) through a fibrocartilaginous transition region. This transition is believed to facilitate force transmission between the two dissimilar tissues by ameliorating potentially damaging interfacial stress concentrations. The transition region is impaired or lost upon tendon/ligament injury and is not regenerated following surgical repair or natural healing, exposing the tissue to risk of reinjury. The need to regenerate a robust tendon-to-bone insertion has led a number of tissue engineering repair strategies. This review treats the tendon-to-bone insertion site as a tissue structure whose primary role is mechanical and discusses current and emerging strategies for engineering the tendon/ligament-to-bone insertion in this context. The focus lies on strategies for producing mechanical structures that can guide and subsequently sustain a graded tissue structure and the associated cell populations.

  17. Diabetes Alters Mechanical Properties and Collagen Fiber Re-Alignment in Multiple Mouse Tendons

    PubMed Central

    Connizzo, Brianne K.; Bhatt, Pankti R.; Liechty, Kenneth W.; Soslowsky, Louis J.

    2014-01-01

    Tendons function to transfer load from muscle to bone through their complex composition and hierarchical structure, consisting mainly of type I collagen. Recent evidence suggests that type II diabetes may cause alterations in collagen structure, such as irregular fibril morphology and density, which could play a role in the mechanical function of tendons. Using the db/db mouse model of type II diabetes, the diabetic skin was found to have impaired biomechanical properties when compared to the non-diabetic group. The purpose of this study was to assess the effect of diabetes on biomechanics, collagen fiber re-alignment, and biochemistry in three functionally different tendons (Achilles, supraspinatus, patellar) using the db/db mouse model. Results showed that cross-sectional area and stiffness, but not modulus, were significantly reduced in all three tendons. However, the tendon response to load (transition strain, collagen fiber re-alignment) occurred earlier in the mechanical test, contrary to expectations. In addition, the patellar tendon had an altered response to diabetes when compared to the other two tendons, with no changes in fiber realignment and decreased collagen content at the midsubstance of the tendon. Overall, type II diabetes alters tendon mechanical properties and the dynamic response to load. PMID:24833253

  18. Freezing does not alter multiscale tendon mechanics and damage mechanisms in tension.

    PubMed

    Lee, Andrea H; Elliott, Dawn M

    2017-12-01

    It is common in biomechanics to use previously frozen tissues, where it is assumed that the freeze-thaw process does not cause consequential mechanical or structural changes. We have recently quantified multiscale tendon mechanics and damage mechanisms using previously frozen tissue, where damage was defined as an irreversible change in the microstructure that alters the macroscopic mechanical parameters. Because freezing has been shown to alter tendon microstructures, the objective of this study was to determine if freezing alters tendon multiscale mechanics and damage mechanisms. Multiscale testing using a protocol that was designed to evaluate tendon damage (tensile stress-relaxation followed by unloaded recovery) was performed on fresh and previously frozen rat tail tendon fascicles. At both the fascicle and fibril levels, there was no difference between the fresh and frozen groups for any of the parameters, suggesting that there is no effect of freezing on tendon mechanics. After unloading, the microscale fibril strain fully recovered, and interfibrillar sliding only partially recovered, suggesting that the tendon damage is localized to the interfibrillar structures and that mechanisms of damage are the same in both fresh and previously frozen tendons. © 2017 New York Academy of Sciences.

  19. Electromechanical impedance-based health diagnosis for tendon and anchorage zone in a nuclear containment structure

    NASA Astrophysics Data System (ADS)

    Min, Jiyoung; Shim, Hyojin; Yun, Chung-Bang

    2012-04-01

    For a nuclear containment structure, the structural health monitoring is essential because of its high potential risk and grave social impact. In particular, the tendon and anchorage zone are to be monitored because they are under high tensile or compressive stress. In this paper, a method to monitor the tendon force and the condition of the anchorage zone is presented by using the impedance-based health diagnosis system. First, numerical simulations were conducted for cases with various loose tensile forces on the tendon as well as damages on the bearing plate and concrete structure. Then, experimental studies were carried out on a scaled model of the anchorage system. The relationship between the loose tensile force and the impedance-based damage index was analyzed by a regression analysis. When a structure gets damaged, the damage index increases so that the status of damage can be identified. The results of the numerical and experimental studies indicate a big potential of the proposed impedance-based method for monitoring the tendon and anchorage system.

  20. An age-related study of morphology and cross-link composition of collagen fibrils in the digital flexor tendons of young thoroughbred horses.

    PubMed

    Patterson-Kane, J C; Parry, D A; Birch, H L; Goodship, A E; Firth, E C

    1997-01-01

    The superficial digital flexor tendon is the most commonly injured tendon in the racing Thoroughbred. Despite the clinical significance of this structure, only limited data exist regarding normal age-related morphology of the tensile units, the collagen fibrils. The age at which these collagen fibrils become mature in composition and structure may be of importance. Consequently, the association of age and collagen fibril crosslink composition, diameter distribution and crimp morphology in the superficial and deep digital flexor tendons of Thoroughbreds up to and including three years of age has been studied. Replacement of immature crosslinks, peaking of the collagen fibril mass-average diameter and collagen fibril index, and stabilization of collagen crimp morphology changes supported the hypothesis that both digital flexor tendons become mature in structure by two years of age.

  1. [Anterior dislocation of the popliteus tendon].

    PubMed

    Martinez Molina, Oscar

    2009-01-01

    Review the most relevant aspects of the posterolateral corner anatomy of the knee, based on the analysis of papers that throughout the years have made important contributions to the knowledge of these structures. Last et al rejected the idea that the popliteal tendon is an isolated structure, suggesting rather that its variants are closely linked to other anatomical structures. The studies by Tria et al contributed the features of the tendon as it attaches to the lateral condyle, just to mention a couple of examples. This is the case of a 48 year-old female patient with a knee injury caused by an external rotation mechanism. Clinical features included pain, a protruding sensation in the lateral aspect of the knee, and voluntary pseudoblocking resulting from external rotation maneuvers. Knee arthroscopy was performed and dislocation of the popliteal tendon anterior to the lateral condyle was diagnosed, besides a longitudinal tear. The tendon was repositioned, radiofrequency was applied to both the tendon and the popliteal hiatus, and the former was kept in place with a plaster cast worn for 6 weeks. Even though the isolated tear or avulsion of the tendon has already been reported, the dislocation or instability of the popliteal tendon as it relates to the lateral femoral condyle has apparently not been approached yet. As we did in this case, other authors have also confirmed the diagnosis arthroscopically, Naver in 1985, Rose in 1988, and Burstein in 1990.

  2. Coordinated Development of Muscles and Tendon-Like Structures: Early Interactions in the Drosophila Leg.

    PubMed

    Soler, Cedric; Laddada, Lilia; Jagla, Krzysztof

    2016-01-01

    The formation of the musculoskeletal system is a remarkable example of tissue assembly. In both vertebrates and invertebrates, precise connectivity between muscles and skeleton (or exoskeleton) via tendons or equivalent structures is fundamental for movement and stability of the body. The molecular and cellular processes underpinning muscle formation are well-established and significant advances have been made in understanding tendon development. However, the mechanisms contributing to proper connection between these two tissues have received less attention. Observations of coordinated development of tendons and muscles suggest these tissues may interact during the different steps in their development. There is growing evidence that, depending on animal model and muscle type, these interactions can take place from progenitor induction to the final step of the formation of the musculoskeletal system. Here, we briefly review and compare the mechanisms behind muscle and tendon interaction throughout the development of vertebrates and Drosophila before going on to discuss our recent findings on the coordinated development of muscles and tendon-like structures in Drosophila leg. By altering apodeme formation (the functional Drosophila equivalent of tendons in vertebrates) during the early steps of leg development, we affect the spatial localization of subsequent myoblasts. These findings provide the first evidence of the developmental impact of early interactions between muscle and tendon-like precursors, and confirm the appendicular Drosophila muscle system as a valuable model for studying these processes.

  3. Coordinated Development of Muscles and Tendon-Like Structures: Early Interactions in the Drosophila Leg

    PubMed Central

    Soler, Cedric; Laddada, Lilia; Jagla, Krzysztof

    2016-01-01

    The formation of the musculoskeletal system is a remarkable example of tissue assembly. In both vertebrates and invertebrates, precise connectivity between muscles and skeleton (or exoskeleton) via tendons or equivalent structures is fundamental for movement and stability of the body. The molecular and cellular processes underpinning muscle formation are well-established and significant advances have been made in understanding tendon development. However, the mechanisms contributing to proper connection between these two tissues have received less attention. Observations of coordinated development of tendons and muscles suggest these tissues may interact during the different steps in their development. There is growing evidence that, depending on animal model and muscle type, these interactions can take place from progenitor induction to the final step of the formation of the musculoskeletal system. Here, we briefly review and compare the mechanisms behind muscle and tendon interaction throughout the development of vertebrates and Drosophila before going on to discuss our recent findings on the coordinated development of muscles and tendon-like structures in Drosophila leg. By altering apodeme formation (the functional Drosophila equivalent of tendons in vertebrates) during the early steps of leg development, we affect the spatial localization of subsequent myoblasts. These findings provide the first evidence of the developmental impact of early interactions between muscle and tendon-like precursors, and confirm the appendicular Drosophila muscle system as a valuable model for studying these processes. PMID:26869938

  4. Tendon material properties vary and are interdependent among turkey hindlimb muscles

    PubMed Central

    Matson, Andrew; Konow, Nicolai; Miller, Samuel; Konow, Pernille P.; Roberts, Thomas J.

    2012-01-01

    SUMMARY The material properties of a tendon affect its ability to store and return elastic energy, resist damage, provide mechanical feedback and amplify or attenuate muscle power. While the structural properties of a tendon are known to respond to a variety of stimuli, the extent to which material properties vary among individual muscles remains unclear. We studied the tendons of six different muscles in the hindlimb of Eastern wild turkeys to determine whether there was variation in elastic modulus, ultimate tensile strength and resilience. A hydraulic testing machine was used to measure tendon force during quasi-static lengthening, and a stress–strain curve was constructed. There was substantial variation in tendon material properties among different muscles. Average elastic modulus differed significantly between some tendons, and values for the six different tendons varied nearly twofold, from 829±140 to 1479±106 MPa. Tendons were stretched to failure, and the stress at failure, or ultimate tensile stress, was taken as a lower-limit estimate of tendon strength. Breaking tests for four of the tendons revealed significant variation in ultimate tensile stress, ranging from 66.83±14.34 to 112.37±9.39 MPa. Resilience, or the fraction of energy returned in cyclic length changes was generally high, and one of the four tendons tested was significantly different in resilience from the other tendons (range: 90.65±0.83 to 94.02±0.71%). An analysis of correlation between material properties revealed a positive relationship between ultimate tensile strength and elastic modulus (r2=0.79). Specifically, stiffer tendons were stronger, and we suggest that this correlation results from a constrained value of breaking strain, which did not vary significantly among tendons. This finding suggests an interdependence of material properties that may have a structural basis and may explain some adaptive responses observed in studies of tendon plasticity. PMID:22771746

  5. Tendon material properties vary and are interdependent among turkey hindlimb muscles.

    PubMed

    Matson, Andrew; Konow, Nicolai; Miller, Samuel; Konow, Pernille P; Roberts, Thomas J

    2012-10-15

    The material properties of a tendon affect its ability to store and return elastic energy, resist damage, provide mechanical feedback and amplify or attenuate muscle power. While the structural properties of a tendon are known to respond to a variety of stimuli, the extent to which material properties vary among individual muscles remains unclear. We studied the tendons of six different muscles in the hindlimb of Eastern wild turkeys to determine whether there was variation in elastic modulus, ultimate tensile strength and resilience. A hydraulic testing machine was used to measure tendon force during quasi-static lengthening, and a stress-strain curve was constructed. There was substantial variation in tendon material properties among different muscles. Average elastic modulus differed significantly between some tendons, and values for the six different tendons varied nearly twofold, from 829±140 to 1479±106 MPa. Tendons were stretched to failure, and the stress at failure, or ultimate tensile stress, was taken as a lower-limit estimate of tendon strength. Breaking tests for four of the tendons revealed significant variation in ultimate tensile stress, ranging from 66.83±14.34 to 112.37±9.39 MPa. Resilience, or the fraction of energy returned in cyclic length changes was generally high, and one of the four tendons tested was significantly different in resilience from the other tendons (range: 90.65±0.83 to 94.02±0.71%). An analysis of correlation between material properties revealed a positive relationship between ultimate tensile strength and elastic modulus (r(2)=0.79). Specifically, stiffer tendons were stronger, and we suggest that this correlation results from a constrained value of breaking strain, which did not vary significantly among tendons. This finding suggests an interdependence of material properties that may have a structural basis and may explain some adaptive responses observed in studies of tendon plasticity.

  6. A medical imaging analysis system for trigger finger using an adaptive texture-based active shape model (ATASM) in ultrasound images

    PubMed Central

    Chuang, Bo-I; Kuo, Li-Chieh; Yang, Tai-Hua; Su, Fong-Chin; Jou, I-Ming; Lin, Wei-Jr; Sun, Yung-Nien

    2017-01-01

    Trigger finger has become a prevalent disease that greatly affects occupational activity and daily life. Ultrasound imaging is commonly used for the clinical diagnosis of trigger finger severity. Due to image property variations, traditional methods cannot effectively segment the finger joint’s tendon structure. In this study, an adaptive texture-based active shape model method is used for segmenting the tendon and synovial sheath. Adapted weights are applied in the segmentation process to adjust the contribution of energy terms depending on image characteristics at different positions. The pathology is then determined according to the wavelet and co-occurrence texture features of the segmented tendon area. In the experiments, the segmentation results have fewer errors, with respect to the ground truth, than contours drawn by regular users. The mean values of the absolute segmentation difference of the tendon and synovial sheath are 3.14 and 4.54 pixels, respectively. The average accuracy of pathological determination is 87.14%. The segmentation results are all acceptable in data of both clear and fuzzy boundary cases in 74 images. And the symptom classifications of 42 cases are also a good reference for diagnosis according to the expert clinicians’ opinions. PMID:29077737

  7. Time-Dependent Alterations of MMPs, TIMPs and Tendon Structure in Human Achilles Tendons after Acute Rupture

    PubMed Central

    Minkwitz, Susann; Schmock, Aysha; Kurtoglu, Alper; Tsitsilonis, Serafeim; Manegold, Sebastian; Klatte-Schulz, Franka

    2017-01-01

    A balance between matrix metalloproteinases (MMPs) and their inhibitors (TIMPs) is required to maintain tendon homeostasis. Variation in this balance over time might impact on the success of tendon healing. This study aimed to analyze structural changes and the expression profile of MMPs and TIMPs in human Achilles tendons at different time-points after rupture. Biopsies from 37 patients with acute Achilles tendon rupture were taken at surgery and grouped according to time after rupture: early (2–4 days), middle (5–6 days), and late (≥7 days), and intact Achilles tendons served as control. The histological score increased from the early to the late time-point after rupture, indicating the progression towards a more degenerative status. In comparison to intact tendons, qRT-PCR analysis revealed a significantly increased expression of MMP-1, -2, -13, TIMP-1, COL1A1, and COL3A1 in ruptured tendons, whereas TIMP-3 decreased. Comparing the changes over time post rupture, the expression of MMP-9, -13, and COL1A1 significantly increased, whereas MMP-3 and -10 expression decreased. TIMP expression was not significantly altered over time. MMP staining by immunohistochemistry was positive in the ruptured tendons exemplarily analyzed from early and late time-points. The study demonstrates a pivotal contribution of all investigated MMPs and TIMP-1, but a minor role of TIMP-2, -3, and -4, in the early human tendon healing process. PMID:29053586

  8. Is the chronic painful tendinosis tendon a strong tendon?: a case study involving an Olympic weightlifter with chronic painful Jumper's knee.

    PubMed

    Gisslén, Karl; Ohberg, Lars; Alfredson, Håkan

    2006-09-01

    The chronic painful tendinosis tendon is generally considered a degenerated and weak tendon. However, this has not been scientifically verified, and is to be considered a hypothesis. We present here a case study involving a high-level Olympic weightlifter with chronic painful patellar tendinosis who started heavy-weight training very early after successful treatment with sclerosing injections. A 25-year-old super heavy-weight (+105 kg) Olympic weightlifter with 9 months duration of severe pain (prohibiting full training) in the proximal patellar tendon, where ultrasound and Doppler showed a widened tendon with structural changes and neovascularisation, was given one treatment with ultrasound and Doppler-guided injections of the sclerosing agent polidocanol. The injections targeted the neovessels posterior to the tendon. The patient was pain-free after the treatment, and already after 2-weeks he started with heavy-weight training (240 kg in deep squats) to try to qualify for the Olympics. Additional very heavy training on training camps, most often without having any discomfort or pain in the patellar tendon, resulted in Swedish records and ninth place at the European Championships 17 weeks after the treatment. Despite beating the national records, he did not qualify for the Olympics. Ultrasound and Doppler follow-ups have shown only a few remaining neovessels, and little structural tendon changes. This case questions previous theories about the weak tendinosis tendon, and stresses the importance of studies evaluating tendon strength.

  9. Isolation, culture and biological characteristics of multipotent porcine tendon-derived stem cells.

    PubMed

    Yang, Jinjuan; Zhao, Qianjun; Wang, Kunfu; Ma, Caiyun; Liu, Hao; Liu, Yingjie; Guan, Weijun

    2018-06-01

    Tendon-derived stem cells (TDSCs), a postulated multi-potential stem cell population, play significant role in the postnatal replenishment of tendon injuries. However, the majority of experimental materials were obtained from horse, rat, human and rabbit, but rarely from pig. In this research, 1‑day‑old pig was chosen as experimental sample source to isolate and culture TDSCs in vitro. Specific markers of TDSCs were then characterized by immunofluorescence and reverse transcription polymerase chain reaction (RT‑PCR) assays. The results showed that TDSCs could be expanded for 11 passages in vitro. The expression of specific markers, such as collagen Ⅰ, collagen Ⅲ, α‑smooth muscle actin (α‑SMA), CD105 and CD90 were observed by immunofluorescence and RT‑PCR. TDSCs were induced to differentiate into adipocytes, osteoblasts and chondrocytes, respectively. These results suggest that TDSCs isolated from porcine tendon exhibit the characteristics of multipotent stem cells. TDSCs, therefore, may be potential candidates for cellular transplantation therapy and tissue engineering in tendon injuries.

  10. Detection of partial-thickness tears in ligaments and tendons by Stokes-polarimetry imaging

    NASA Astrophysics Data System (ADS)

    Kim, Jihoon; John, Raheel; Walsh, Joseph T.

    2008-02-01

    A Stokes polarimetry imaging (SPI) system utilizes an algorithm developed to construct degree of polarization (DoP) image maps from linearly polarized light illumination. Partial-thickness tears of turkey tendons were imaged by the SPI system in order to examine the feasibility of the system to detect partial-thickness rotator cuff tear or general tendon pathology. The rotating incident polarization angle (IPA) for the linearly polarized light provides a way to analyze different tissue types which may be sensitive to IPA variations. Degree of linear polarization (DoLP) images revealed collagen fiber structure, related to partial-thickness tears, better than standard intensity images. DoLP images also revealed structural changes in tears that are related to the tendon load. DoLP images with red-wavelength-filtered incident light may show tears and related organization of collagen fiber structure at a greater depth from the tendon surface. Degree of circular polarization (DoCP) images exhibited well the horizontal fiber orientation that is not parallel to the vertically aligned collagen fibers of the tendon. The SPI system's DOLP images reveal alterations in tendons and ligaments, which have a tissue matrix consisting largely of collagen, better than intensity images. All polarized images showed modulated intensity as the IPA was varied. The optimal detection of the partial-thickness tendon tears at a certain IPA was observed. The SPI system with varying IPA and spectral information can improve the detection of partial-thickness rotator cuff tears by higher visibility of fiber orientations and thereby improve diagnosis and treatment of tendon related injuries.

  11. Is Statin Use Associated With Tendon Rupture? A Population-Based Retrospective Cohort Analysis.

    PubMed

    Contractor, Tahmeed; Beri, Abhimanyu; Gardiner, Joseph C; Tang, Xiaoqin; Dwamena, Francesca C

    2015-01-01

    Previous case reports and small studies have suggested that 3-hydroxy-3-methylglutaryl-CoA reductase inhibitors (HMG-CoA-Is) may increase the risk of tendon rupture. We conducted a population-based retrospective cohort evaluation to better assess this relationship. From approximately 800,000 enrollees of a private insurance database, those who were aged ≤64 years with at least 1 year of continuous enrollment were selected. Exposure was defined as initiation of HMG-CoA-I after the beginning of the study period. Each exposed person was matched with 2 controls of similar age and gender. Baseline characteristics, including known risk factors for tendon rupture, were compared between exposed and control cohorts with fidelity to the study's matched design. After adjusting for differences in follow-up and baseline characteristics, incidence rate ratios for tendon rupture was assessed in HMG-CoA-I users and nonusers. A total of 34,749 exposed patients were matched with 69,498 controls. There was no difference in the occurrence of tendon ruptures in HMG-CoA-I users versus nonusers. The results remained unchanged after adjustment for age and gender. In conclusion, this population-based retrospective cohort evaluation suggests that use of HMG-CoA-Is as a group are not associated with tendon rupture.

  12. Tendon entheses of the human masticatory muscles.

    PubMed

    Hems, T; Tillmann, B

    2000-09-01

    Tendons attach to the limb skeleton via chondral-apophysary or periosteal-diaphysary entheses. It was the aim of the present study to investigate the tendon entheses of the temporal, the masseter, as well as the medial and lateral pterygoid muscles, considering the biomechanics and the mode of osteogenesis at the attachment sites. The origin and insertion zones of the four masticatory muscles were studied histologically and by polarization light microscopy in six halves of human heads. Contrary to the limb skeleton no causal relationship between the histological structure of the tendon entheses and the osteogenic mode of the bone areas involved was observed in the masticatory muscles that were studied. Based on the histological findings, a purely structural classification of the tendon attachments irrespective of the osteogenesis is therefore proposed that is applicable to the entire skeleton. It is possible to distinguish between tendon entheses inserting into periosteum, into bone or into fibrocartilage. Tendon attachments with periosteal insertion are found at the temporal plane, the retromolar triangle, zygomatic arch, lateral pterygoid plate, in the caudal zone of the pterygoid fovea of the neck of mandible as well as major portions of the ramus and angle of the mandible. The attachment zones in which collagen fibrils of tendons insert into the bone via the periosteum correspond in their structure to plane periosteal-diaphysary insertions into the diaphyses of long bones. Attachment zones to the bone are present at the inferior temporal line, the base of the coronoid process, the caudal surface of the zygomatic arch, the cranial zones of the pterygoid fovea of the neck of the mandible as well as at circumscribed areas of the ramus and angle of the mandible. In these zones the collagen fibers of the tendon insert immediately into the bone without any mediation of other tissues. The entheses resemble those of circumscribed periosteal-diaphysary attachments to long bones. Fibrocartilaginous entheses occur at the coronoid process, the cranialmost portions of the pterygoid fovea of the neck of the mandible as well as in circumscribed areas of the medial and lateral facets of the angle of the mandible. The structures of these attachment sites are comparable to chondral-apophysary tendon attachments. As for masticatory muscles, the described forms of tendon entheses occur at the same time in the majority of the attachment sites. From the structure of the three types of tendon entheses it is possible to conclude that they fulfill a biomechanical function similar to that of the limb skeleton, namely adapting the different elasticity moduli of bone and tendon tissues. From a technical perspective they can be considered to act as an "angle and stretching brake".

  13. The Achilles tendon: fundamental properties and mechanisms governing healing

    PubMed Central

    Freedman, Benjamin R.; Gordon, Joshua A.; Soslowsky, Louis J.

    2014-01-01

    Summary This review highlights recent research on Achilles tendon healing, and comments on the current clinical controversy surrounding the diagnosis and treatment of injury. The processes of Achilles tendon healing, as demonstrated through changes in its structure, composition, and biomechanics, are reviewed. Finally, a review of tendon developmental biology and mechano transductive pathways is completed to recognize recent efforts to augment injured Achilles tendons, and to suggest potential future strategies for therapeutic intervention and functional tissue engineering. Despite an abundance of clinical evidence suggesting that current treatments and rehabilitation strategies for Achilles tendon ruptures are equivocal, significant questions remain to fully elucidate the basic science mechanisms governing Achilles tendon injury, healing, treatment, and rehabilitation. PMID:25332943

  14. Structural changes in loaded equine tendons can be monitored by a novel spectroscopic technique

    PubMed Central

    Kostyuk, Oksana; Birch, Helen L; Mudera, Vivek; Brown, Robert A

    2004-01-01

    This study aimed to investigate the preferential collagen fibril alignment in unloaded and loaded tendons using elastic scattering spectroscopy. The device consisted of an optical probe, a pulsed light source (320–860 nm), a spectrometer and a PC. Two probes with either 2.75 mm or 300 μm source-detector separations were used to monitor deep and superficial layers, respectively. Equine superficial digital flexor tendons were subjected to ex vivo progressive tensional loading. Seven times more backscattered light was detected parallel rather than perpendicular to the tendon axis with the 2.75 mm separation probe in unloaded tendons. In contrast, using the 300 μm separation probe the plane of maximum backscatter (3-fold greater) was perpendicular to the tendon axis. There was no optical anisotropy in the cross-sectional plane of the tendon (i.e. the transversely cut tendon surface), with no structural anisotropy. During mechanical loading (9–14% strain) backscatter anisotropy increased 8.5- to 18.5-fold along the principal strain axis for 2.75 mm probe separation, but almost disappeared in the perpendicular plane (measured using the 300 μm probe separation). Optical (anisotropy) and mechanical (strain) measurements were highly correlated. We conclude that spatial anisotropy of backscattered light can be used for quantitative monitoring of collagen fibril alignment and tissue reorganization during loading, with the potential for minimally invasive real-time structural monitoring of fibrous tissues in normal, pathological or repairing tissues and in tissue engineering. PMID:14578479

  15. Chronic alterations in growth hormone/insulin-like growth factor-I signaling lead to changes in mouse tendon structure.

    PubMed

    Nielsen, R H; Clausen, N M; Schjerling, P; Larsen, J O; Martinussen, T; List, E O; Kopchick, J J; Kjaer, M; Heinemeier, K M

    2014-02-01

    The growth hormone/insulin-like growth factor-I (GH/IGF-I) axis is an important stimulator of collagen synthesis in connective tissue, but the effect of chronically altered GH/IGF-I levels on connective tissue of the muscle-tendon unit is not known. We studied three groups of mice; 1) giant transgenic mice that expressed bovine GH (bGH) and had high circulating levels of GH and IGF-I, 2) dwarf mice with a disrupted GH receptor gene (GHR-/-) leading to GH resistance and low circulating IGF-I, and 3) a wild-type control group (CTRL). We measured the ultra-structure, collagen content and mRNA expression (targets: GAPDH, RPLP0, IGF-IEa, IGF-IR, COL1A1, COL3A1, TGF-β1, TGF-β2, TGF-β3, versican, scleraxis, tenascin C, fibronectin, fibromodulin, decorin) in the Achilles tendon, and the mRNA expression was also measured in calf muscle (same targets as tendon plus IGF-IEb, IGF-IEc). We found that GHR-/- mice had significantly lower collagen fibril volume fraction in Achilles tendon, as well as decreased mRNA expression of IGF-I isoforms and collagen types I and III in muscle compared to CTRL. In contrast, the mRNA expression of IGF-I isoforms and collagens in bGH mice was generally high in both tendon and muscle compared to CTRL. Mean collagen fibril diameter was significantly decreased with both high and low GH/IGF-I signaling, but the GHR-/- mouse tendons were most severely affected with a total loss of the normal bimodal diameter distribution. In conclusion, chronic manipulation of the GH/IGF-I axis influenced both morphology and mRNA levels of selected genes in the muscle-tendon unit of mice. Whereas only moderate structural changes were observed with up-regulation of GH/IGF-I axis, disruption of the GH receptor had pronounced effects upon tendon ultra-structure. © 2013.

  16. Tension Regulation at the Suture Lines for Repair of Neglected Achilles Tendon Laceration.

    PubMed

    Massoud, Elsayed Ibraheem Elsayed

    2017-03-01

    Operative intervention is the preferred option for management of the neglected laceration of the Achilles tendon. However, the commonly used techniques rarely follow the principles of the regenerative medicine for the restoration of the lost tissue. This study postulated that incorporation of the autogenous tendon graft would properly progress when the interplay between mechanical loading and healing phases was correctly applied. A prospective study included 15 patients who were treated for neglected Achilles tendon laceration using the technique of lengthening of the proximal tendon stump. An absorbable reinforcement suture was used for control of the mechanical environment at the suture lines. By an average 5 years of the prospective follow-up, all the repaired tendons had restored continuity and length. The calf circumference equalized to the uninjured side in 12 patients. However, 3 patients had calf atrophy but they improved compared to the preoperative measurements. Sonogram confirmed the restoration of the normal thickness and the gliding characteristics of the repaired tendon. The technique restored continuity and tension of the repaired tendon, preserved the calf circumference, and prevented peritendinous adhesions. The absorbable reinforcement suture spontaneously allowed for the mechanical loading of the grafted tendon. Level IV, case series.

  17. Fibrocartilage in tendons and ligaments — an adaptation to compressive load

    PubMed Central

    BENJAMIN, M.; RALPHS, J. R.

    1998-01-01

    Where tendons and ligaments are subject to compression, they are frequently fibrocartilaginous. This occurs at 2 principal sites: where tendons (and sometimes ligaments) wrap around bony or fibrous pulleys, and in the region where they attach to bone, i.e. at their entheses. Wrap-around tendons are most characteristic of the limbs and are commonly wider at their point of bony contact so that the pressure is reduced. The most fibrocartilaginous tendons are heavily loaded and permanently bent around their pulleys. There is often pronounced interweaving of collagen fibres that prevents the tendons from splaying apart under compression. The fibrocartilage can be located within fascicles, or in endo- or epitenon (where it may protect blood vessels from compression or allow fascicles to slide). Fibrocartilage cells are commonly packed with intermediate filaments which could be involved in transducing mechanical load. The ECM often contains aggrecan which allows the tendon to imbibe water and withstand compression. Type II collagen may also be present, particularly in tendons that are heavily loaded. Fibrocartilage is a dynamic tissue that disappears when the tendons are rerouted surgically and can be maintained in vitro when discs of tendon are compressed. Finite element analyses provide a good correlation between its distribution and levels of compressive stress, but at some locations fibrocartilage is a sign of pathology. Enthesis fibrocartilage is most typical of tendons or ligaments that attach to the epiphyses of long bones where it may also be accompanied by sesamoid and periosteal fibrocartilages. It is characteristic of sites where the angle of attachment changes throughout the range of joint movement and it reduces wear and tear by dissipating stress concentration at the bony interface. There is a good correlation between the distribution of fibrocartilage within an enthesis and the levels of compressive stress. The complex interlocking between calcified fibrocartilage and bone contributes to the mechanical strength of the enthesis and cartilage-like molecules (e.g. aggrecan and type II collagen) in the ECM contribute to its ability to withstand compression. Pathological changes are common and are known as enthesopathies. PMID:10029181

  18. Post-tensioning tendon force loss detection using low power pulsed eddy current measurement

    NASA Astrophysics Data System (ADS)

    Kim, Ji-Min; Lee, Jun; Sohn, Hoon

    2018-04-01

    In the field of bridge engineering, pre-fabrication of a bridge member and its construction in site have been issued and studied, which achieves improved quality and rapid construction. For integration of those pre-fabricated segments into a structural member (i.e., a concrete slab, girder and pier), post-tensioning (PT) technique is adopted utilizing a high-strength steel tendon, and an effective investigation of the remaining PT tendon force is essential to assure an overall structural integrity. This study proposes a pulsed eddy current based tendon force loss detection system. A compact eddy current sensor is designed to be installed on the surface of an anchor holding a steel PT tendon. The intensity of the induced eddy current varies with PT tendon force alteration due to the magnetostriction effect of a ferromagnetic material. The advantages of the proposed system are as follows: (1) low power consumption, (2) rapid inspection, and (3) simple installation. Its performance was validated experimentally in a full-scale lab test of a 3.3-m long, 15.2-mm diameter mono-tendon that was tensioned using a universal testing machine. Tendon force was controlled from 20 to 180 kN with 20 kN interval, and eddy current responses were measured and analyzed at each force condition. The proposed damage index and the amount of force loss of PT tendon were monotonically related, and an excessive loss as much as 30 % of an initially-introduced tendon force was successfully predicted.

  19. Observation of tendon repair in animal model using second-harmonic-generation microscopy

    NASA Astrophysics Data System (ADS)

    Hase, Eiji; Minamikawa, Takeo; Sato, Katsuya; Takahashi, Mitsuhiko; Yasui, Takashi

    2016-03-01

    Tendon rupture is a trauma difficult to recover the condition before injury. In previous researches, tensile test and staining method have been widely used to elucidate the mechanism of the repair process from the viewpoints of the mechanical property and the histological findings. However, since both methods are destructive and invasive, it is difficult to obtain both of them for the same sample. If both the mechanical property and the histological findings can be obtained from the same sample, one may obtain new findings regarding mechanisms of tendon repairing process. In this paper, we used second-harmonic-generation (SHG) microscopy, showing high selectivity and good image contrast to collagen molecules as well as high spatial resolution, optical three-dimensional sectioning, deep penetration, and without additional staining. Since SHG light intensity sensitively reflects the structural maturity of collagen molecule and its aggregates, it will be a good indicator for the repairing degree of the ruptured tendon. From comparison of SHG images between the 4-weeks-repaired tendon and the sound tendon in the animal model, we confirmed that SHG light intensity of the repaired tendon was significantly lower than that of the sound tendon, indicating that the collagen structure in the repaired tendon is still immature. Furthermore, we performed both SHG imaging and the tensile test for the same sample, and confirmed a correlation between them. This result shows a potential of SHG light for an indicator of the histological and mechanical recovery of the ruptured tendon.

  20. Therapeutics for tendon regeneration: a multidisciplinary review of tendon research for improved healing.

    PubMed

    Paredes, J J; Andarawis-Puri, Nelly

    2016-11-01

    Tendon injuries, known as tendinopathies, are common musculoskeletal injuries that affect a wide range of the population. Canonical tendon healing is characterized by fibrosis, scar formation, and the loss of tissue mechanical and structural properties. Understanding the regenerative tendon environment is an area of increasing interest in the field of musculoskeletal research. Previous studies have focused on utilizing individual elements from the fields of biomechanics, developmental biology, cell and growth factor therapy, and tissue engineering in an attempt to develop regenerative tendon therapeutics. Still, the specific mechanism for regenerative healing remains unknown. In this review, we highlight some of the current approaches of tendon therapeutics and elucidate the differences along the tendon midsubstance and enthesis, exhibiting the necessity of location-specific tendon therapeutics. Furthermore, we emphasize the necessity of further interdisciplinary research in order to reach the desired goal of fully understanding the mechanisms underlying regenerative healing. © 2016 New York Academy of Sciences.

  1. Cadaver study of anatomic landmark identification for placing ankle arthroscopy portals.

    PubMed

    Scheibling, B; Koch, G; Clavert, P

    2017-05-01

    Arthroscopy-assisted surgery is now widely used at the ankle for osteochondral lesions of the talus, anterior and posterior impingement syndromes, talocrural or subtalar fusion, foreign body removal, and ankle instability. Injuries to the vessels and nerves may occur during these procedures. To determine whether ultrasound topographic identification of vulnerable structures decreased the risk of iatrogenic injuries to vessels, nerves, and tendons and influenced the distance separating vulnerable structures from the arthroscope introduced through four different portals. Ultrasonography to identify vulnerable structures before or during arthroscopic surgery on the ankle may be useful. Twenty fresh cadaver ankles from body donations to the anatomy institute in Strasbourg, France, were divided into two equal groups. Preoperative ultrasonography to mark the trajectories of vessels, nerves, and tendons was performed in one group but not in the other. The portals were created using a 4-mm trocar. Each portal was then dissected. The primary evaluation criterion was the presence or absence of injuries to vessels, nerves, and tendons. The secondary evaluation criterion was the distance between these structures and the arthroscope. No tendon injuries occurred with ultrasonography. Without ultrasonography, there were two full-thickness tendon lesions, one to the extensor hallucis longus and the other to the Achilles tendon. Furthermore, with the anterolateral, anteromedial, and posteromedial portals, the distance separating the vessels and nerves from the arthroscope was greater with than without ultrasonography (P=0.041, P=0.005, and P=0.002), respectively; no significant difference was found with the anterior portal. Preoperative ultrasound topographic identification decreases the risk of iatrogenic injury to the vessels, nerves, and tendons during ankle arthroscopy and places these structures at a safer distance from the arthroscope. Our hypothesis was confirmed. IV, cadaver study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  2. [Ultrastructural observation of tendonization of artificial tendon 109HH in rabbit].

    PubMed

    Liu, L; Cao, Q; Xiao, H

    1995-09-01

    Ten New Zealand rabbits were divided into 5 groups at random. Calcaneal tendons were cut bilaterally, then atificial tendon 109HH was used to connect the two ends of the cut tendon. Ultrastructural changes of control group and experimental groups at 2, 6, 12, 28 weeks after section were observed. The results showed that fibroblast proliferated and a lot of ribosome and RER appeared in plasm during 2 approximately 6 weeks, indicating artificial tendon caused fibroblast proliferation. During this period, fibroblast over synthesized collagenous protein and the synthesis of collagenous fibers peaked. During 12-28 weeks, the number of fibroblasts and the synthesis of collagenous protein decreased. Finally, fibroblasts became inactive tendon cells. With the formation of new tendons, the artificial tendens were degradated and absorbed, and disappeared after 12 weeks. The new tendon fibers became thicker and had the correct direction through reconstruction. The structure and function of new tendons could be restored to be consistent with normal values.

  3. Medial gastrocnemius structure and gait kinetics in spastic cerebral palsy and typically developing children: A cross-sectional study.

    PubMed

    Martín Lorenzo, Teresa; Rocon, Eduardo; Martínez Caballero, Ignacio; Lerma Lara, Sergio

    2018-05-01

    To compare medial gastrocnemius muscle-tendon structure, gait propulsive forces, and ankle joint gait kinetics between typically developing children and those with spastic cerebral palsy, and to describe significant associations between structure and function in children with spastic cerebral palsy.A sample of typically developing children (n = 9 /16 limbs) and a sample of children with spastic cerebral palsy (n = 29 /43 limbs) were recruited. Ultrasound and 3-dimensional motion capture were used to assess muscle-tendon structure, and propulsive forces and ankle joint kinetics during gait, respectively.Children with spastic cerebral palsy had shorter fascicles and muscles, and longer Achilles tendons than typically developing children. Furthermore, total negative power and peak negative power at the ankle were greater, while total positive power, peak positive power, net power, total vertical ground reaction force, and peak vertical and anterior ground reaction forces were smaller compared to typically developing children. Correlation analyses revealed that smaller resting ankle joint angles and greater maximum dorsiflexion in children with spastic cerebral palsy accounted for a significant decrease in peak negative power. Furthermore, short fascicles, small fascicle to belly ratios, and large tendon to fascicle ratios accounted for a decrease in propulsive force generation.Alterations observed in the medial gastrocnemius muscle-tendon structure of children with spastic cerebral palsy may impair propulsive mechanisms during gait. Therefore, conventional treatments should be revised on the basis of muscle-tendon adaptations.

  4. How does a cadaver model work for testing ultrasound diagnostic capability for rheumatic-like tendon damage?

    PubMed

    Janta, Iustina; Morán, Julio; Naredo, Esperanza; Nieto, Juan Carlos; Uson, Jacqueline; Möller, Ingrid; Bong, David; Bruyn, George A W; D Agostino, Maria Antonietta; Filippucci, Emilio; Hammer, Hilde Berner; Iagnocco, Annamaria; Terslev, Lene; González, Jorge Murillo; Mérida, José Ramón; Carreño, Luis

    2016-06-01

    To establish whether a cadaver model can serve as an effective surrogate for the detection of tendon damage characteristic of rheumatoid arthritis (RA). In addition, we evaluated intraobserver and interobserver agreement in the grading of RA-like tendon tears shown by US, as well as the concordance between the US findings and the surgically induced lesions in the cadaver model. RA-like tendon damage was surgically induced in the tibialis anterior tendon (TAT) and tibialis posterior tendon (TPT) of ten ankle/foot fresh-frozen cadaveric specimens. Of the 20 tendons examined, six were randomly assigned a surgically induced partial tear; six a complete tear; and eight left undamaged. Three rheumatologists, experts in musculoskeletal US, assessed from 1 to 5 the quality of US imaging of the cadaveric models on a Likert scale. Tendons were then categorized as having either no damage, (0); partial tear, (1); or complete tear (2). All 20 tendons were blindly and independently evaluated twice, over two rounds, by each of the three observers. Overall, technical performance was satisfactory for all items in the two rounds (all values over 2.9 in a Likert scale 1-5). Intraobserver and interobserver agreement for US grading of tendon damage was good (mean κ values 0.62 and 0.71, respectively), with greater reliability found in the TAT than the TPT. Concordance between US findings and experimental tendon lesions was acceptable (70-100 %), again greater for the TAT than for the TPT. A cadaver model with surgically created tendon damage can be useful in evaluating US metric properties of RA tendon lesions.

  5. Biomechanical behavior of muscle-tendon complex during dynamic human movements.

    PubMed

    Fukashiro, Senshi; Hay, Dean C; Nagano, Akinori

    2006-05-01

    This paper reviews the research findings regarding the force and length changes of the muscle-tendon complex during dynamic human movements, especially those using ultrasonography and computer simulation. The use of ultrasonography demonstrated that the tendinous structures of the muscle-tendon complex are compliant enough to influence the biomechanical behavior (length change, shortening velocity, and so on) of fascicles substantially. It was discussed that the fascicles are a force generator rather than a work generator; the tendinous structures function not only as an energy re-distributor but also as a power amplifier, and the interaction between fascicles and tendinous structures is essential for generating higher joint power outputs during the late pushoff phase in human vertical jumping. This phenomenon could be explained based on the force-length/velocity relationships of each element (contractile and series elastic elements) in the muscle-tendon complex during movements. Through computer simulation using a Hill-type muscle-tendon complex model, the benefit of making a countermovement was examined in relation to the compliance of the muscle-tendon complex and the length ratio between the contractile and series elastic elements. Also, the integral roles of the series elastic element were simulated in a cyclic human heel-raise exercise. It was suggested that the storage and reutilization of elastic energy by the tendinous structures play an important role in enhancing work output and movement efficiency in many sorts of human movements.

  6. Is passive stiffness in human muscles related to the elasticity of tendon structures?

    PubMed

    Kubo, K; Kanehisa, H; Fukunaga, T

    2001-08-01

    The purpose of this study was to examine in vivo whether passive stiffness in human muscles was related to the elasticity of tendon structures and to performance during stretch-shortening cycle exercise. Passive torque of plantar flexor muscles was measured during passive stretch from 90 degrees (anatomical position) to 65 degrees of dorsiflexion at a constant velocity of 5 degrees.s-1. The slope of the linear portion of the passive torque-angle curve during stretching was defined as the passive stiffness of the muscle. The elongation of the tendon and aponeurosis of the medial gastrocnemius muscle (MG) was directly measured using ultrasonography during ramp isometric plantar flexion up to the voluntary maximum. The relationship between the estimated muscle force of MG and tendon elongation was fitted to a linear regression, the slope of which was defined as the stiffness of the tendon. In addition, the dynamic torques during maximal voluntary concentric plantar flexion with and without prior eccentric contraction were determined at a constant velocity of 120 degrees.s-1. There were no significant correlations between passive stiffness and either the tendon stiffness (r = 0.19, P > 0.05) or the relative increase in torque with prior eccentric contraction (r = -0.19, P > 0.05). However, tendon stiffness was negatively correlated to the relative increase in torque output (r = -0.42, P < 0.05). The present results suggested that passive stiffness was independent of the elasticity of tendon structures, and had no favourable effect on the muscle performance during stretch-shortening cycle exercise.

  7. Characteristics and Clinical Outcomes in Overhead Sports Athletes after Rotator Cuff Repair

    PubMed Central

    Inui, Hiroaki; Ninomiya, Hiroki; Tanaka, Hiroshi; Nobuhara, Katsuya

    2017-01-01

    Rotator cuff tears in young overhead sports athletes are rare. The pathomechanism causing rotator cuff tears in young overhead athletes is different from that in aged patients. The purpose of this study was to investigate rotator cuff tear characteristics in young overhead sports athletes to reveal the pathomechanism causing these injuries. This study included 25 overhead sports athletes less than 30 years old with atraumatic rotator cuff tears necessitating repair. Rotator cuff tear characteristics were evaluated intraoperatively, including rotator cuff tear shape and injured rotator cuff tendon. Clinical outcome measures were assessed before surgery and at the final follow-up. In this study, 22 patients reported minimal to no shoulder pain and returned to sports without significant complaints at last follow-up. The isolated infraspinatus tendon was most often injured; the incidence rate of the tear at this site was 32% (8 cases). In the deceleration phase of overhead motion, the eccentric contraction force of the ISP (infraspinatus) tendon peaks and the increased load leads to injury at the ISP tendon. The pathomechanism of rotator cuff injuries in young overhead athletes might be not only internal or subacromial impingement, but also these mechanisms. PMID:28702502

  8. Posterior Displacement of Supraspinatus Central Tendon Observed on Magnetic Resonance Imaging: A Useful Preoperative Indicator of Rotator Cuff Tear Characteristics.

    PubMed

    Updegrove, Gary F; Armstrong, April D; Mosher, Timothy J; Kim, H Mike

    2015-11-01

    To characterize the orientation of the normal supraspinatus central tendon and describe the displacement patterns of the central tendon in rotator cuff tears using a magnetic resonance imaging (MRI)-based method. We performed a retrospective MRI and chart review of 183 patients with a rotator cuff tear (cuff tear group), 52 with a labral tear but no rotator cuff tear (labral tear group), and 74 with a normal shoulder (normal group). The orientation of the supraspinatus central tendon relative to the bicipital groove was evaluated based on axial MRI and was numerically represented by the shortest distance from the lateral extension line of the central tendon to the bicipital groove. Tear size, fatty degeneration, and involvement of the anterior supraspinatus were evaluated to identify the factors associated with orientation changes. The mean distance from the bicipital groove to the central tendon line was 0.7 mm and 1.3 mm in the normal group and labral tear group, respectively. Full-thickness cuff tears involving the anterior supraspinatus showed a significantly greater distance (17.7 mm) than those sparing the anterior supraspinatus (4.9 mm, P = .001). Fatty degeneration of the supraspinatus was significantly correlated with the distance (P = .006). Disruption of the anterior supraspinatus and fatty degeneration of the supraspinatus were independent predictors of posterior displacement. The supraspinatus central tendon has a constant orientation toward the bicipital groove in normal shoulders, and the central tendon is frequently displaced posteriorly in full-thickness rotator cuff tears involving the anterior leading edge of the supraspinatus. The degree of posterior displacement is proportional to tear size and severity of fatty degeneration of the supraspinatus muscle. A simple and quick assessment of the central tendon orientation on preoperative MRI can be a useful indicator of tear characteristics, potentially providing insight into the intraoperative repair strategy. Level IV, diagnostic case-control study. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  9. Simultaneous anatomic reconstruction of the acromioclavicular and coracoclavicular ligaments using a single tendon graft.

    PubMed

    Shin, Sang-Jin; Campbell, Sean; Scott, Jonathan; McGarry, Michelle H; Lee, Thay Q

    2014-09-01

    The purpose of this study was to introduce a novel surgical technique for simultaneous anatomic reconstruction of the acromioclavicular and coracoclavicular ligaments using a single tendon graft and to compare its biomechanical characteristics to those of a coracoid cerclage reconstruction of the coracoclavicular ligaments. Six matched pairs of human acromioclavicular joints with an average age of 54.8 ± 7.8 years were used. One shoulder from each pair received the single tendon acromioclavicular-coracoclavicular reconstruction; the contralateral shoulder received the coracoid cerclage reconstruction. Bovine extensor tendon was used for both techniques. The single tendon acromioclavicular-coracoclavicular reconstruction technique provided anatomic restoration of the two coracoclavicular ligaments and the superior and inferior acromioclavicular ligaments simultaneously using one coracoid hole, one acromion hole, and two clavicular holes with interference screws. Anterior-posterior and superior-inferior translations were quantified for all specimens before and after reconstruction, followed by load to failure testing. Following coracoid cerclage reconstruction, total anterior-posterior translation was significantly greater than intact (10.0 ± 5.7 mm; p = 0.008). Following single tendon acromioclavicular-coracoclavicular reconstruction, there was no significant difference in anterior-posterior translation compared to intact (-1.6 ± 2.2 mm; n.s.). The coracoid cerclage technique demonstrated significantly greater anterior-posterior translation than the single tendon acromioclavicular-coracoclavicular technique (p = 0.007). Both techniques restored superior-inferior translation to the intact condition (n.s.). Ultimate load, deformation at ultimate load, and energy absorbed at ultimate load were significantly greater after acromioclavicular-coracoclavicular reconstruction than after coracoid cerclage reconstruction (p < 0.05). This novel single tendon anatomic acromioclavicular-coracoclavicular reconstruction provided greater stability and stronger load to failure characteristics than the isolated coracoid cerclage reconstruction. A simultaneous acromioclavicular-coracoclavicular reconstruction technique using a single free tendon graft provided anatomic reconstruction of the conoid, trapezoid, and superior and inferior acromioclavicular ligaments and may reduce postoperative subluxation.

  10. Comparison of a novel bone-tendon allograft with a human dermis-derived patch for repair of chronic large rotator cuff tears using a canine model.

    PubMed

    Smith, Matthew J; Cook, James L; Kuroki, Keiichi; Jayabalan, Prakash S; Cook, Cristi R; Pfeiffer, Ferris M; Waters, Nicole P

    2012-02-01

    This study tested a bone-tendon allograft versus human dermis patch for reconstructing chronic rotator cuff repair by use of a canine model. Mature research dogs (N = 15) were used. Radiopaque wire was placed in the infraspinatus tendon (IST) before its transection. Three weeks later, radiographs showed IST retraction. Each dog then underwent 1 IST treatment: debridement (D), direct repair of IST to bone with a suture bridge and human dermis patch augmentation (GJ), or bone-tendon allograft (BT) reconstruction. Outcome measures included lameness grading, radiographs, and ultrasonographic assessment. Dogs were killed 6 months after surgery and both shoulders assessed biomechanically and histologically. BT dogs were significantly (P = .01) less lame than the other groups. BT dogs had superior bone-tendon, tendon, and tendon-muscle integrity compared with D and GJ dogs. Biomechanical testing showed that the D group had significantly (P = .05) more elongation than the other groups whereas BT had stiffness and elongation characteristics that most closely matched normal controls. Radiographically, D and GJ dogs showed significantly more retraction than BT dogs (P = .003 and P = .045, respectively) Histologically, GJ dogs had lymphoplasmacytic infiltrates, tendon degeneration and hypocellularity, and poor tendon-bone integration. BT dogs showed complete incorporation of allograft bone into host bone, normal bone-tendon junctions, and well-integrated allograft tendon. The bone-tendon allograft technique re-establishes a functional IST bone-tendon-muscle unit and maintains integrity of repair in this model. Clinical trials using this bone-tendon allograft technique are warranted. Copyright © 2012 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  11. The role of bone sialoprotein in the tendon-bone insertion.

    PubMed

    Marinovich, Ryan; Soenjaya, Yohannes; Wallace, Gregory Q; Zuskov, Andre; Dunkman, Andrew; Foster, Brian L; Ao, Min; Bartman, Kevin; Lam, Vida; Rizkalla, Amin; Beier, Frank; Somerman, Martha J; Holdsworth, David W; Soslowsky, Louis J; Lagugné-Labarthet, François; Goldberg, Harvey A

    2016-01-01

    Tendons/ligaments insert into bone via a transitional structure, the enthesis, which is susceptible to injury and difficult to repair. Fibrocartilaginous entheses contain fibrocartilage in their transitional zone, part of which is mineralized. Mineral-associated proteins within this zone have not been adequately characterized. Members of the Small Integrin Binding Ligand N-linked Glycoprotein (SIBLING) family are acidic phosphoproteins expressed in mineralized tissues. Here we show that two SIBLING proteins, bone sialoprotein (BSP) and osteopontin (OPN), are present in the mouse enthesis. Histological analyses indicate that the calcified zone of the quadriceps tendon enthesis is longer in Bsp(-/-) mice, however no difference is apparent in the supraspinatus tendon enthesis. In an analysis of mineral content within the calcified zone, micro-CT and Raman spectroscopy reveal that the mineral content in the calcified fibrocartilage of the quadriceps tendon enthesis are similar between wild type and Bsp(-/-) mice. Mechanical testing of the patellar tendon shows that while the tendons fail under similar loads, the Bsp(-/-) patellar tendon is 7.5% larger in cross sectional area than wild type tendons, resulting in a 16.5% reduction in failure stress. However, Picrosirius Red staining shows no difference in collagen organization. Data collected here indicate that BSP is present in the calcified fibrocartilage of murine entheses and suggest that BSP plays a regulatory role in this structure, influencing the growth of the calcified fibrocartilage in addition to the weakening of the tendon mechanical properties. Based on the phenotype of the Bsp(-/-) mouse enthesis, and the known in vitro functional properties of the protein, BSP may be a useful therapeutic molecule in the reattachment of tendons and ligaments to bone. Copyright © 2016 International Society of Matrix Biology. All rights reserved.

  12. The Role of Bone Sialoprotein in the Tendon-Bone Insertion

    PubMed Central

    Marinovich, Ryan; Soenjaya, Yohannes; Wallace, Gregory Q.; Zuskov, Andre; Dunkman, Andrew; Foster, Brian L.; Ao, Min; Bartman, Kevin; Lam, Vida; Rizkalla, Amin; Beier, Frank; Somerman, Martha J.; Holdsworth, David W.; Soslowsky, Louis J.; Lagugné-Labarthet, François; Goldberg, Harvey A.

    2016-01-01

    Tendons/ligaments insert into bone via a transitional structure, the enthesis, which is susceptible to injury and difficult to repair. Fibrocartilaginous entheses contain fibrocartilage in their transitional zone, part of which is mineralized. Mineral-associated proteins within this zone have not been adequately characterized. Members of the Small Integrin Binding Ligand N-Linked Glycoprotein (SIBLING) family are acidic phosphoproteins expressed in mineralized tissues. Here we show that two SIBLING proteins, bone sialoprotein (BSP) and osteopontin (OPN), are present in the mouse enthesis. Histological analyses indicate that the calcified zone of the quadriceps tendon enthesis is longer in Bsp−/− mice, however no difference is apparent in the supraspinatus tendon enthesis. In an analysis of mineral content within the calcified zone, micro-CT and Raman spectroscopy reveal that the mineral content in the calcified fibrocartilage of the quadriceps tendon enthesis are similar between wild type and Bsp−/− mice. Mechanical testing of the patellar tendon shows that while the tendons fail under similar loads, the Bsp−/− patellar tendon is 7.5% larger in cross sectional area than wild type tendons, resulting in a 16.5% reduction in failure stress. However, picrosirius red staining shows no difference in collagen organization. Data collected here indicate that BSP is present in the calcified fibrocartilage of murine entheses and suggest that BSP plays a regulatory role in this structure, influencing the growth of the calcified fibrocartilage in addition to the weakening of the tendon mechanical properties. Based on the phenotype of the Bsp−/− mouse enthesis, and the known in vitro functional properties of the protein, BSP may be a useful therapeutic molecule in the reattachment of tendons and ligaments to bone. PMID:26826499

  13. Living nanofiber yarn-based woven biotextiles for tendon tissue engineering using cell tri-culture and mechanical stimulation.

    PubMed

    Wu, Shaohua; Wang, Ying; Streubel, Philipp N; Duan, Bin

    2017-10-15

    Non-woven nanofibrous scaffolds have been developed for tendon graft application by using electrospinning strategies. However, electrospun nanofibrous scaffolds face some obstacles and limitations, including suboptimal scaffold structure, weak tensile and suture-retention strengths, and compact structure for cell infiltration. In this work, a novel nanofibrous, woven biotextile, fabricated based on electrospun nanofiber yarns, was implemented as a tissue engineered tendon scaffold. Based on our modified electrospinning setup, polycaprolactone (PCL) nanofiber yarns were fabricated with reproducible quality, and were further processed into plain-weaving fabrics interlaced with polylactic acid (PLA) multifilaments. Nonwoven nanofibrous PCL meshes with random or aligned fiber structures were generated using typical electrospinning as comparative counterparts. The woven fabrics contained 3D aligned microstructures with significantly larger pore size and obviously enhanced tensile mechanical properties than their nonwoven counterparts. The biological results revealed that cell proliferation and infiltration, along with the expression of tendon-specific genes by human adipose derived mesenchymal stem cells (HADMSC) and human tenocytes (HT), were significantly enhanced on the woven fabrics compared with those on randomly-oriented or aligned nanofiber meshes. Co-cultures of HADMSC with HT or human umbilical vein endothelial cells (HUVEC) on woven fabrics significantly upregulated the functional expression of most tenogenic markers. HADMSC/HT/HUVEC tri-culture on woven fabrics showed the highest upregulation of most tendon-associated markers than all the other mono- and co-culture groups. Furthermore, we conditioned the tri-cultured constructs with dynamic conditioning and demonstrated that dynamic stretch promoted total collagen secretion and tenogenic differentiation. Our nanofiber yarn-based biotextiles have significant potential to be used as engineered scaffolds to synergize the multiple cell interaction and mechanical stimulation for promoting tendon regeneration. Tendon grafts are essential for the treatment of various tendon-related conditions due to the inherently poor healing capacity of native tendon tissues. In this study, we combined electrospun nanofiber yarns with textile manufacturing strategies to fabricate nanofibrous woven biotextiles with hierarchical features, aligned fibrous topography, and sufficient mechanical properties as tendon tissue engineered scaffolds. Comparing to traditional electrospun random or aligned meshes, our novel nanofibrous woven fabrics possess strong tensile and suture-retention strengths and larger pore size. We also demonstrated that the incorporation of tendon cells and vascular cells promoted the tenogenic differentiation of the engineered tendon constructs, especially under dynamic stretch. This study not only presents a novel tissue engineered tendon scaffold fabrication technique but also provides a useful strategy to promote tendon differentiation and regeneration. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  14. The role of animal models in tendon research

    PubMed Central

    Hast, M. W.; Zuskov, A.; Soslowsky, L. J.

    2014-01-01

    Tendinopathy is a debilitating musculoskeletal condition which can cause significant pain and lead to complete rupture of the tendon, which often requires surgical repair. Due in part to the large spectrum of tendon pathologies, these disorders continue to be a clinical challenge. Animal models are often used in this field of research as they offer an attractive framework to examine the cascade of processes that occur throughout both tendon pathology and repair. This review discusses the structural, mechanical, and biological changes that occur throughout tendon pathology in animal models, as well as strategies for the improvement of tendon healing. Cite this article: Bone Joint Res 2014;3:193–202. PMID:24958818

  15. Rescue plan for Achilles: Therapeutics steering the fate and functions of stem cells in tendon wound healing.

    PubMed

    Schneider, Magdalena; Angele, Peter; Järvinen, Tero A H; Docheva, Denitsa

    2017-12-24

    Due to the increasing age of our society and a rise in engagement of young people in extreme and/or competitive sports, both tendinopathies and tendon ruptures present a clinical and financial challenge. Tendon has limited natural healing capacity and often responds poorly to treatments, hence it requires prolonged rehabilitation in most cases. Till today, none of the therapeutic options has provided successful long-term solutions, meaning that repaired tendons do not recover their complete strength and functionality. Our understanding of tendon biology and healing increases only slowly and the development of new treatment options is insufficient. In this review, following discussion on tendon structure, healing and the clinical relevance of tendon injury, we aim to elucidate the role of stem cells in tendon healing and discuss new possibilities to enhance stem cell treatment of injured tendon. To date, studies mainly apply stem cells, often in combination with scaffolds or growth factors, to surgically created tendon defects. Deeper understanding of how stem cells and vasculature in the healing tendon react to growth factors, common drugs used to treat injured tendons and promising cellular boosters could help to develop new and more efficient ways to manage tendon injuries. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.

  16. Structure formation in fibrous materials based on poly-3-hydroxybutyrate for traumatology

    NASA Astrophysics Data System (ADS)

    Olkhov, A. A.; Sklyanchuk, E. D.; Staroverova, O. V.; Abbasov, T. A.; Guryev, V. V.; Akatov, V. S.; Fadeyeva, I. S.; Fesenko, N. I.; Filatov, Yu. N.; Iordanskii, A. L.

    2015-10-01

    The paper reviews the structure formation of fibrous materials based on poly-3-hydroxybutyrate depending on parameters of electrospinning and characteristics of polymer solution. Fiber structure was studied by DSC, ESR and SEM. The molecular weight affects the diameter and uniformity of the fiber. An electromechanical impact leads to an orientation of crystalline structure in the fiber. The design of an artificial bioresorbable implant based on nano- and microfibers of poly-3-hydroxybutyrate is created. Dynamics of growth of mesenchymal stem cells on poly-3-hydroxybutyrate scaffolds is studied. Successful field tests of implants of the Achilles tendon in Wistar rats are conducted.

  17. Effects of resistance and stretching training programmes on the viscoelastic properties of human tendon structures in vivo

    PubMed Central

    Kubo, Keitaro; Kanehisa, Hiroaki; Fukunaga, Tetsuo

    2002-01-01

    The present study examined whether resistance and stretching training programmes altered the viscoelastic properties of human tendon structures in vivo. Eight subjects completed 8 weeks (4 days per week) of resistance training which consisted of unilateral plantar flexion at 70 % of one repetition maximum with 10 repetitions per set (5 sets per day). They performed resistance training (RT) on one side and resistance training and static stretching training (RST; 10 min per day, 7 days per week) on the other side. Before and after training, the elongation of the tendon structures in the medial gastrocnemius muscle was directly measured using ultrasonography, while the subjects performed ramp isometric plantar flexion up to the voluntary maximum, followed by a ramp relaxation. The relationship between estimated muscle force (Fm) and tendon elongation (L) was fitted to a linear regression, the slope of which was defined as stiffness. The hysteresis was calculated as the ratio of the area within the Fm-L loop to the area beneath the load portion of the curve. The stiffness increased significantly by 18.8 ± 10.4 % for RT and 15.3 ± 9.3 % for RST. There was no significant difference in the relative increase of stiffness between RT and RST. The hysteresis, on the other hand, decreased 17 ± 20 % for RST, but was unchanged for RT. These results suggested that the resistance training increased the stiffness of tendon structures as well as muscle strength and size, and the stretching training affected the viscosity of tendon structures but not the elasticity. PMID:11773330

  18. COMPARISON OF FUNCTIONAL ACTIVITIES ON STRUCTURAL CHANGES OF THE INFERIOR PATELLAR POLE

    PubMed Central

    Wallmann, Harvey; Stalcup, Patrick; DiTommaso, Katie

    2017-01-01

    Background It is well known that eccentric and concentric exercise produce varied amounts of stress on the connective tissues. Diagnostic ultrasound has been used to measure these structural changes by observing fascicle length, angle, and thickness; however, there is a lack of evidence comparing the structural changes as it relates to eccentric, concentric, and stretching protocols. Purpose The purpose of this study was to compare the acute effects of static stretching, eccentric, concentric, and a combination of eccentric/concentric exercises on structural changes of the muscle tendon unit at the inferior patellar pole utilizing the diagnostic ultrasound. Study Design A repeated measures 2 × 4 within factorial study design with repeated measures on both factors was used to determine the differences in patellar tendon thickness within and between groups. Methods Forty-seven healthy subjects were screened for any lower extremity deficits or orthopaedic pathology. Forty-four (N=44) subjects completed all four protocols; the attrition was due to injuries to the lower extremity, occurring unrelated to the study. A baseline measurement of the anterior inferior patellar tendon was performed with the diagnostic ultrasound prior to each participant completing one of the four interventions per week over a four-week period. Interventions completed by each participant included static stretching, concentric, eccentric, and combined concentric and eccentric exercises. Immediately following each intervention, a post-intervention inferior patellar tendon measurement was recorded using the diagnostic ultrasound. Results Significant differences in anterior to posterior tendon thickness of the inferior patellar tendon were observed between pre (4.983 ± 0.041mm) and post (5.198 ± 0.055mm) measurements (p<0.0005) for the main effect of time. However, no differences in tendon thickness were noted comparing each intervention to one another (p=0.351). Conclusion Differences in tendon thickness were noted acutely for pre- to post measurements across all interventions. Further research is needed to determine if differences in tendon thickness exist with a longer duration of exercise over time and with different types of intervention. PMID:29234561

  19. PAPP-A affects tendon structure and mechanical properties.

    PubMed

    Yang, Tai-Hua; Thoreson, Andrew R; An, Kai-Nan; Zhao, Chunfeng; Conover, Cheryl A; Amadio, Peter C

    2015-10-01

    Pregnancy-associated plasma protein-A (PAPP-A) serves to increase local insulin-like growth factor (IGF) stimulation of proliferation and differentiation in many tissues through proteolysis of inhibitory IGF-binding proteins. The purpose of this study was to investigate the effects of PAPP-A on tendon structure and mechanical properties. A total of 30 tails from 6-month-old mice were tested with 10 tails in each of following groups: PAPP-A knockout (KO), skeletal-specific PAPP-A overexpressing transgenic (Tg) and wild type (WT). Morphologically, the total tail cross-sectional area (CSA), individual tissue CSAs of bone, muscle and tendon, and fascicle diameter were measured. A fascicle pullout test was performed to assess stiffness and strength of interfascicular structures. Fascicles were mechanically characterized through low and high displacement rate uniaxial tension tests providing modulus at each rate, hysteresis area and stress relaxation ratio. The KO mice had a smaller total tail CSA (p<0.05), fascicle diameter (p<0.05), absolute tendon CSA (p<0.05), fast and slow stiffness (p<0.05 for both) and larger hysteresis area (p<0.05) compared to WT and Tg mice. On the other hand, the Tg mice had a larger fascicle diameter (p<0.05), absolute tendon CSA (p<0.05), higher interfascicular strength and stiffness (p<0.05) and lower fascicular modulus at low displacement rates (p<0.05) compared to WT and KO mice. Tg mice also had larger total tail CSA area (p<0.05) and smaller hysteresis area (p<0.05) than KO mice, and larger normalized tendon CSA (p<0.05) than WT mice. Based on these data, we conclude that PAPP-A affects fascicle structure, thereby affecting tendon phenotype. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Beneficial Effects of Autologous Bone Marrow-Derived Mesenchymal Stem Cells in Naturally Occurring Tendinopathy

    PubMed Central

    Smith, Roger Kenneth Whealands; Werling, Natalie Jayne; Dakin, Stephanie Georgina; Alam, Rafiqul; Goodship, Allen E.; Dudhia, Jayesh

    2013-01-01

    Tendon injuries are a common age-related degenerative condition where current treatment strategies fail to restore functionality and normal quality of life. This disease also occurs naturally in horses, with many similarities to human tendinopathy making it an ideal large animal model for human disease. Regenerative approaches are increasingly used to improve outcome involving mesenchymal stem cells (MSCs), supported by clinical data where injection of autologous bone marrow derived MSCs (BM-MSCs) suspended in marrow supernatant into injured tendons has halved the re-injury rate in racehorses. We hypothesized that stem cell therapy induces a matrix more closely resembling normal tendon than the fibrous scar tissue formed by natural repair. Twelve horses with career-ending naturally-occurring superficial digital flexor tendon injury were allocated randomly to treatment and control groups. 1X107 autologous BM-MSCs suspended in 2 ml of marrow supernatant were implanted into the damaged tendon of the treated group. The control group received the same volume of saline. Following a 6 month exercise programme horses were euthanized and tendons assessed for structural stiffness by non-destructive mechanical testing and for morphological and molecular composition. BM-MSC treated tendons exhibited statistically significant improvements in key parameters compared to saline-injected control tendons towards that of normal tendons and those in the contralateral limbs. Specifically, treated tendons had lower structural stiffness (p<0.05) although no significant difference in calculated modulus of elasticity, lower (improved) histological scoring of organisation (p<0.003) and crimp pattern (p<0.05), lower cellularity (p<0.007), DNA content (p<0.05), vascularity (p<0.03), water content (p<0.05), GAG content (p<0.05), and MMP-13 activity (p<0.02). Treatment with autologous MSCs in marrow supernatant therefore provides significant benefits compared to untreated tendon repair in enhancing normalisation of biomechanical, morphological, and compositional parameters. These data in natural disease, with no adverse findings, support the use of this treatment for human tendon injuries. PMID:24086616

  1. Immunolocalization of Collagens (I and III) and Cartilage Oligomeric Matrix Protein in the Normal and Injured Equine Superficial Digital Flexor Tendon

    PubMed Central

    2013-01-01

    This is a descriptive study of tendon pathology with different structural appearances of repair tissue correlated to immunolocalization of cartilage oligomeric matrix protein (COMP) and type I and III collagens and expression of COMP mRNA. The material consists of nine tendons from seven horses (5–25 years old; mean age of 10 years) with clinical tendinopathy and three normal tendons from horses (3, 3, and 13 years old) euthanized for non-orthopedic reasons. The injured tendons displayed different repair-tissue appearances with organized and disorganized fibroblastic regions as well as areas of necrosis. The normal tendons presented distinct immunoreactivity for COMP and expression of COMP mRNA and type I collagen in the normal aligned fiber structures, but no immunolabeling of type III collagen. However, immunoreactivity for type III collagen was present in the endotenon surrounding the fiber bundles, where no expression of COMP could be seen. Immunostaining for type I and III collagens was present in all of the pathologic regions indicating repair tissue. Interestingly, the granulation tissues showed immunostaining for COMP and expression of COMP mRNA, indicating a role for COMP in repair and remodeling of the tendon after fiber degeneration and rupture. The present results suggest that not only type III collagen but also COMP is involved in the repair and remodeling processes of the tendon. PMID:23020676

  2. Modelling approaches for evaluating multiscale tendon mechanics

    PubMed Central

    Fang, Fei; Lake, Spencer P.

    2016-01-01

    Tendon exhibits anisotropic, inhomogeneous and viscoelastic mechanical properties that are determined by its complicated hierarchical structure and varying amounts/organization of different tissue constituents. Although extensive research has been conducted to use modelling approaches to interpret tendon structure–function relationships in combination with experimental data, many issues remain unclear (i.e. the role of minor components such as decorin, aggrecan and elastin), and the integration of mechanical analysis across different length scales has not been well applied to explore stress or strain transfer from macro- to microscale. This review outlines mathematical and computational models that have been used to understand tendon mechanics at different scales of the hierarchical organization. Model representations at the molecular, fibril and tissue levels are discussed, including formulations that follow phenomenological and microstructural approaches (which include evaluations of crimp, helical structure and the interaction between collagen fibrils and proteoglycans). Multiscale modelling approaches incorporating tendon features are suggested to be an advantageous methodology to understand further the physiological mechanical response of tendon and corresponding adaptation of properties owing to unique in vivo loading environments. PMID:26855747

  3. Experimental verification of the influence of time-dependent material properties on long-term bridge characteristics.

    DOT National Transportation Integrated Search

    2006-08-01

    Post-tensioned cast-in-place box girder bridges are commonly used in California. Losses in tension in : the steel prestressing tendons used in these bridges occur over time due to creep and shrinkage of : concrete and relaxation of the tendons. The u...

  4. Initial experience with visualizing hand and foot tendons by dual-energy computed tomography.

    PubMed

    Deng, Kai; Sun, Cong; Liu, Cheng; Ma, Rui

    2009-01-01

    To assess the feasibility of visualizing hand and foot tendons by dual-energy computed tomography (CT). Twenty patients who suffered from hand or feet pains were scanned on dual-source CT (Definition, Forchheim, Germany) with dual-energy mode at tube voltages of 140 and 80 kV and a corresponding ratio of 1:4 between tube currents. The reconstructed images were postprocessed by volume rendering techniques (VRT) and multiplanar reconstruction (MPR). All of the suspected lesions were confirmed by surgery or follow-up studies. Twelve patients (total of 24 hands and feet, respectively) were found to be normal and the other eight patients (total of nine hands and feet, respectively) were found abnormal. Dual-energy techniques are very useful in visualizing tendons of the hands and feet, such as flexor pollicis longus tendon, flexor digitorum superficialis/profundus tendon, Achilles tendon, extensor hallucis longus tendon, and extensor digitorum longus tendon, etc. It can depict the whole shape of the tendons and their fixation points clearly. Peroneus longus tendon in the sole of the foot was not displayed very well. The distal ends of metacarpophalangeal joints with extensor digitoium tendon and extensor pollicis longus tendon were poorly shown. The lesions of tendons such as the circuitry, thickening, and adherence were also shown clearly. Dual-energy CT offers a new method to visualize tendons of the hand and foot. It could clearly display both anatomical structures and pathologic changes of hand and foot tendons.

  5. Mineralization can be an incidental ultrasonographic finding in equine tendons and ligaments.

    PubMed

    O'Brien, Etienne J O; Smith, Roger K W

    2018-05-18

    Tendon/ligament mineralization is recognized in horses but information regarding its clinical significance is limited. The aims of this observational study were to report the structures most commonly affected by ultrasonographically detectable mineralization and, for these, determine frequency of diagnosis and key clinical features. Cases presented at our hospital in April 1999-April 2013 and September 2014-November 2015 were included: a total of 27 horses (22 retrospective, five prospective). Mineralizations were most common in deep digital flexor tendons (10) and suspensory ligament branches (eight), representing 10% and 7% (estimated), respectively, of horses diagnosed with injuries to these structures during the study. Two deep digital flexor tendon and three suspensory ligament branch cases showed bilateral mineralization. Deep digital flexor tendon mineralization was restricted to the digital flexor tendon sheath, most commonly in the proximal sheath (±sesamoidean canal), and seven of 10 cases involved hindlimbs. Suspensory ligament branch mineralization was visible in the same ultrasound window as the proximal sesamoid bones in 10/11 limbs and six of eight cases involved forelimbs. Previous corticosteroid medication was a feature of one deep digital flexor tendon and one suspensory ligament branch case. Mineralization was associated with lameness in some but not all limbs. Mineralized foci within the deep digital flexor tendon preceded hypoechoic lesion formation in two limbs. Of the cases with deep digital flexor tendon or suspensory ligament branch injury only, one of three and two of three cases, respectively, became sound. Findings indicated that tendon/ligament mineralization can be associated with lameness in some horses, but can also be an incidental finding. © 2018 American College of Veterinary Radiology.

  6. Markers for the identification of tendon-derived stem cells in vitro and tendon stem cells in situ - update and future development.

    PubMed

    Lui, Pauline Po Yee

    2015-06-02

    The efficacy of tendon-derived stem cells (TDSCs) for the promotion of tendon and tendon-bone junction repair has been reported in animal studies. Modulation of the tendon stem cell niche in vivo has also been reported to influence tendon structure. There is a need to have specific and reliable markers that can define TDSCs in vitro and tendon stem cells in situ for several reasons: to understand the basic biology of TDSCs and their subpopulations in vitro; to understand the identity, niches and functions of tendon/progenitor stem cells in vivo; to meet the governmental regulatory requirements for quality of TDSCs when translating the exciting preclinical findings into clinical trial/practice; and to develop new treatment strategies for mobilizing endogenous stem/progenitor cells in tendon. TDSCs were reported to express the common mesenchymal stem cell (MSC) markers and some embryonic stem cell (ESC) markers, and there were attempts to use these markers to label tendon stem cells in situ. Are these stem cell markers useful for the identification of TDSCs in vitro and tracking of tendon stem cells in situ? This review aims to discuss the values of the panel of MSC, ESC and tendon-related markers for the identification of TDSCs in vitro. Important factors influencing marker expression by TDSCs are discussed. The usefulness and limitations of the panel of MSC, ESC and tendon-related markers for tracking stem cells in tendon, especially tendon stem cells, in situ are then reviewed. Future research directions are proposed.

  7. Non-linear finite element model to assess the effect of tendon forces on the foot-ankle complex.

    PubMed

    Morales-Orcajo, Enrique; Souza, Thales R; Bayod, Javier; Barbosa de Las Casas, Estevam

    2017-11-01

    A three-dimensional foot finite element model with actual geometry and non-linear behavior of tendons is presented. The model is intended for analysis of the lower limb tendon forces effect in the inner foot structure. The geometry of the model was obtained from computational tomographies and magnetic resonance images. Tendon tissue was characterized with the first order Ogden material model based on experimental data from human foot tendons. Kinetic data was employed to set the load conditions. After model validation, a force sensitivity study of the five major foot extrinsic tendons was conducted to evaluate the function of each tendon. A synergic work of the inversion-eversion tendons was predicted. Pulling from a peroneus or tibialis tendon stressed the antagonist tendons while reducing the stress in the agonist. Similar paired action was predicted for the Achilles tendon with the tibialis anterior. This behavior explains the complex control motion performed by the foot. Furthermore, the stress state at the plantar fascia, the talocrural joint cartilage, the plantar soft tissue and the tendons were estimated in the early and late midstance phase of walking. These estimations will help in the understanding of the functional role of the extrinsic muscle-tendon-units in foot pronation-supination. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  8. Collagen V haploinsufficiency in a murine model of classic Ehlers-Danlos syndrome is associated with deficient structural and mechanical healing in tendons.

    PubMed

    Johnston, Jessica M; Connizzo, Brianne K; Shetye, Snehal S; Robinson, Kelsey A; Huegel, Julianne; Rodriguez, Ashley B; Sun, Mei; Adams, Sheila M; Birk, David E; Soslowsky, Louis J

    2017-12-01

    Classic Ehlers-Danlos syndrome (EDS) patients suffer from connective tissue hyperelasticity, joint instability, skin hyperextensibility, tissue fragility, and poor wound healing due to heterozygous mutations in COL5a1 or COL5a2 genes. This study investigated the roles of collagen V in establishing structure and function in uninjured patellar tendons as well as in the injury response using a Col5a1 +/- mouse, a model for classic EDS. These analyses were done comparing tendons from a classic EDS model (Col5a1 +/- ) with wild-type controls. Tendons were subjected to mechanical testing, histological, and fibril analysis before injury as well as 3 and 6 weeks after injury. We found that Col5a1 +/- tendons demonstrated diminished recovery of mechanical competency after injury as compared to normal wild-type tendons, which recovered their pre-injury values by 6 weeks post injury. Additionally, the Col5a1 +/- tendons demonstrated altered fibril morphology and diameter distributions compared to the wild-type tendons. This study indicates that collagen V plays an important role in regulating collagen fibrillogenesis and the associated recovery of mechanical integrity in tendons after injury. In addition, the dysregulation with decreased collagen V expression in EDS is associated with a diminished injury response. The results presented herein have the potential to direct future targeted therapeutics for classic EDS patients. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2707-2715, 2017. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  9. Revisiting the continuum model of tendon pathology: what is its merit in clinical practice and research?

    PubMed Central

    Cook, J L; Rio, E; Purdam, C R; Docking, S I

    2016-01-01

    The pathogenesis of tendinopathy and the primary biological change in the tendon that precipitates pathology have generated several pathoaetiological models in the literature. The continuum model of tendon pathology, proposed in 2009, synthesised clinical and laboratory-based research to guide treatment choices for the clinical presentations of tendinopathy. While the continuum has been cited extensively in the literature, its clinical utility has yet to be fully elucidated. The continuum model proposed a model for staging tendinopathy based on the changes and distribution of disorganisation within the tendon. However, classifying tendinopathy based on structure in what is primarily a pain condition has been challenged. The interplay between structure, pain and function is not yet fully understood, which has partly contributed to the complex clinical picture of tendinopathy. Here we revisit and assess the merit of the continuum model in the context of new evidence. We (1) summarise new evidence in tendinopathy research in the context of the continuum, (2) discuss tendon pain and the relevance of a model based on structure and (3) describe relevant clinical elements (pain, function and structure) to begin to build a better understanding of the condition. Our goal is that the continuum model may help guide targeted treatments and improved patient outcomes. PMID:27127294

  10. Pathological changes in the subsynovial connective tissue increase with self-reported carpal tunnel syndrome symptoms.

    PubMed

    Tat, Jimmy; Wilson, Katherine E; Keir, Peter J

    2015-05-01

    Fibrosis and thickening of the subysnovial connective tissue are the most common pathological findings in carpal tunnel syndrome. The relationship between subsynovial connective tissue characteristics and self-reported carpal tunnel syndrome symptoms was assessed. Symptoms were characterized using the Boston Carpal Tunnel Questionnaire and Katz hand diagram in twenty-two participants (11 with symptoms, 11 with no symptoms). Using ultrasound, the thickness of the subsynovial connective tissue was measured using a thickness ratio (subsynovial thickness/tendon thickness) and gliding function was assessed using a shear strain index ((Displacement(tendon)-Displacement(subsynovial))/Displacement(tendon)x 100). For gliding function, participants performed 10 repeated flexion-extension cycles of the middle finger at a rate of one cycle per second. Participants with symptoms had a 38.5% greater thickness ratio and 39.2% greater shear strain index compared to participants without symptoms (p<0.05). Ultrasound detected differences the SSCT in symptomatic group that was characterized by low self-reported symptom severity scores. This study found ultrasound useful for measuring structural and functional changes in the SSCT that could provide insight in the early pathophysiology associated with carpal tunnel syndrome symptoms. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Evaluating adhesion reduction efficacy of type I/III collagen membrane and collagen-GAG resorbable matrix in primary flexor tendon repair in a chicken model.

    PubMed

    Turner, John B; Corazzini, Rubina L; Butler, Timothy J; Garlick, David S; Rinker, Brian D

    2015-09-01

    Reduction of peritendinous adhesions after injury and repair has been the subject of extensive prior investigation. The application of a circumferential barrier at the repair site may limit the quantity of peritendinous adhesions while preserving the tendon's innate ability to heal. The authors compare the effectiveness of a type I/III collagen membrane and a collagen-glycosaminoglycan (GAG) resorbable matrix in reducing tendon adhesions in an experimental chicken model of a "zone II" tendon laceration and repair. In Leghorn chickens, flexor tendons were sharply divided using a scalpel and underwent repair in a standard fashion (54 total repairs). The sites were treated with a type I/III collagen membrane, collagen-GAG resorbable matrix, or saline in a randomized fashion. After 3 weeks, qualitative and semiquantitative histological analysis was performed to evaluate the "extent of peritendinous adhesions" and "nature of tendon healing." The data was evaluated with chi-square analysis and unpaired Student's t test. For both collagen materials, there was a statistically significant improvement in the degree of both extent of peritendinous adhesions and nature of tendon healing relative to the control group. There was no significant difference seen between the two materials. There was one tendon rupture observed in each treatment group. Surgical handling characteristics were subjectively favored for type I/III collagen membrane over the collagen-GAG resorbable matrix. The ideal method of reducing clinically significant tendon adhesions after injury remains elusive. Both materials in this study demonstrate promise in reducing tendon adhesions after flexor tendon repair without impeding tendon healing in this model.

  12. The influence of freezing on the tensile strength of tendon grafts : a biomechanical study.

    PubMed

    Arnout, Nele; Myncke, Jan; Vanlauwe, Johan; Labey, Luc; Lismont, Daniel; Bellemans, Johan

    2013-08-01

    We investigated the influence of freezing on the tensile strength of fresh frozen tendon grafts. The biomechanical characteristics of tendons that are less commonly used in knee surgery (tibialis anterior, tibialis posterior, peroneus longus and medial and lateral half of Achilles tendons) were compared to those of a semitendinosus and gracilis graft harvested from the same 10 multi-organ donors. All right side tendons constituted the study group and were frozen at -80 degrees C and thawed at room temperature 5 times. All left side tendons were frozen at -80 degrees C and thawed at room temperature once. There were 59 tendons in the control group and 56 in the study group. The looped grafts were clamped at one side using a custom-made freeze clamp and loaded until failure on an Instron 4505 testing machine. The average ultimate failure load was not significantly different between the control and the study group (p > 0.05). The failure load of the medial tendon Achilles was the lowest in both study and control group (p < 0.001). There was no significant difference in maximum stress, maximum displacement, maximum strain and stiffness between the control and study group (p > 0.05). From our study, we conclude that freezing tendons at -80 degrees C and thawing several times does not influence the maximum load, maximum stress, maximum displacement, maximum strain and stiffness. The medial half of the Achilles tendon is clearly the weakest tendon (p < 0.001). These findings show that tendon grafts can be frozen at -80 degrees C and thawed at room temperature several times without altering their biomechanical properties.

  13. Human tendon behaviour and adaptation, in vivo

    PubMed Central

    Magnusson, S Peter; Narici, Marco V; Maganaris, Constantinos N; Kjaer, Michael

    2008-01-01

    Tendon properties contribute to the complex interaction of the central nervous system, muscle–tendon unit and bony structures to produce joint movement. Until recently limited information on human tendon behaviour in vivo was available; however, novel methodological advancements have enabled new insights to be gained in this area. The present review summarizes the progress made with respect to human tendon and aponeurosis function in vivo, and how tendons adapt to ageing, loading and unloading conditions. During low tensile loading or with passive lengthening not only the muscle is elongated, but also the tendon undergoes significant length changes, which may have implications for reflex responses. During active loading, the length change of the tendon far exceeds that of the aponeurosis, indicating that the aponeurosis may more effectively transfer force onto the tendon, which lengthens and stores elastic energy subsequently released during unloading, in a spring-like manner. In fact, data recently obtained in vivo confirm that, during walking, the human Achilles tendon provides elastic strain energy that can decrease the energy cost of locomotion. Also, new experimental evidence shows that, contrary to earlier beliefs, the metabolic activity in human tendon is remarkably high and this affords the tendon the ability to adapt to changing demands. With ageing and disuse there is a reduction in tendon stiffness, which can be mitigated with resistance exercises. Such adaptations seem advantageous for maintaining movement rapidity, reducing tendon stress and risk of injury, and possibly, for enabling muscles to operate closer to the optimum region of the length–tension relationship. PMID:17855761

  14. The distal biceps tendon.

    PubMed

    Schmidt, Christopher C; Jarrett, Claudius D; Brown, Brandon T

    2013-04-01

    Distal biceps tendon ruptures continue to be an important injury seen and treated by upper extremity surgeons. Since the mid-1980s, the emphasis has been placed on techniques that limit complications or improve initial tendon-to-bone fixation strength. Recently, basic science research has expanded the knowledge base regarding the biceps tendon structure, footprint anatomy, and biomechanics. Clinical data have further delineated the results of conservative and surgical management of both partial and complete tears in acute or chronic states. The current literature on the distal biceps tendon is described in detail. Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  15. Increased muscle belly and tendon stiffness in patients with Parkinson's disease, as measured by myotonometry.

    PubMed

    Marusiak, Jarosław; Jaskólska, Anna; Budrewicz, Sławomir; Koszewicz, Magdalena; Jaskólski, Artur

    2011-09-01

    Based on Davis's law, greater tonus of the muscle belly in individuals with Parkinson's disease can create greater tension in the tendon, leading to structural adjustment and an increase in tendon stiffness. Our study aimed to separately assess passive stiffness in the muscle belly and tendon in medicated patients with Parkinson's disease, using myotonometry. We tested 12 patients with Parkinson's disease and 12 healthy matched controls. Passive stiffness of muscle belly and tendon was estimated by myotonometry, electromyography, and mechanomyography in relaxed biceps and triceps brachii muscles. Compared with controls, patients with Parkinson's disease had higher stiffness in the muscle belly and tendon of the biceps brachii and in the tendon of the triceps brachii. In patients with Parkinson's disease, there was a positive correlation between muscle belly stiffness and parkinsonian rigidity in the biceps brachii. Patients with Parkinson's disease have higher passive stiffness of the muscle belly and tendon than healthy matched controls. Copyright © 2011 Movement Disorder Society.

  16. Stem Cell Applications in Tendon Disorders: A Clinical Perspective

    PubMed Central

    Young, Mark

    2012-01-01

    Tendon injuries are a common cause of morbidity and a significant health burden on society. Tendons are structural tissues connecting muscle to bone and are prone to tearing and tendinopathy, an overuse or degenerative condition that is characterized by failed healing and cellular depletion. Current treatments, for tendon tear are conservative, surgical repair or surgical scaffold reconstruction. Tendinopathy is treated by exercises, injection therapies, shock wave treatments or surgical tendon debridement. However, tendons usually heal with fibrosis and scar tissue, which has suboptimal tensile strength and is prone to reinjury, resulting in lifestyle changes with activity restriction. Preclinical studies show that cell therapies have the potential to regenerate rather than repair tendon tissue, a process termed tenogenesis. A number of different cell lines, with varying degrees of differentiation, have being evaluated including stem cells, tendon derived cells and dermal fibroblasts. Even though cellular therapies offer some potential in treating tendon disorders, there have been few published clinical trials to determine the ideal cell source, the number of cells to administer, or the optimal bioscaffold for clinical use. PMID:22448174

  17. Differences between the Cell Populations from the Peritenon and the Tendon Core with Regard to Their Potential Implication in Tendon Repair

    PubMed Central

    Cadby, Jennifer A.; Buehler, Evelyne; Godbout, Charles; van Weeren, P. René; Snedeker, Jess G.

    2014-01-01

    The role of intrinsic and extrinsic healing in injured tendons is still debated. In this study, we characterized cell plasticity, proliferative capacity, and migration characteristics as proxy measures of healing potential in cells derived from the peritenon (extrinsic healing) and compared these to cells from the tendon core (intrinsic healing). Both cell populations were extracted from horse superficial digital flexor tendon and characterized for tenogenic and matrix remodeling markers as well as for rates of migration and replication. Furthermore, colony-forming unit assays, multipotency assays, and real-time quantitative polymerase chain reaction analyses of markers of osteogenic and adipogenic differentiation after culture in induction media were performed. Finally, cellular capacity for differentiation towards a myofibroblastic phenotype was assessed. Our results demonstrate that both tendon- and peritenon-derived cell populations are capable of adipogenic and osteogenic differentiation, with higher expression of progenitor cell markers in peritenon cells. Cells from the peritenon also migrated faster, replicate more quickly, and show higher differentiation potential toward a myofibroblastic phenotype when compared to cells from the tendon core. Based on these data, we suggest that cells from the peritenon have substantial potential to influence tendon-healing outcome, warranting further scrutiny of their role. PMID:24651449

  18. A Biomechanical Comparison of Allograft Tendons for Ligament Reconstruction.

    PubMed

    Palmer, Jeremiah E; Russell, Joseph P; Grieshober, Jason; Iacangelo, Abigail; Ellison, Benjamin A; Lease, T Dylan; Kim, Hyunchul; Henn, R Frank; Hsieh, Adam H

    2017-03-01

    Allograft tendons are frequently used for ligament reconstruction about the knee, but they entail availability and cost challenges. The identification of other tissues that demonstrate equivalent performance to preferred tendons would improve limitations. Hypothesis/Purpose: We compared the biomechanical properties of 4 soft tissue allograft tendons: tibialis anterior (TA), tibialis posterior (TP), peroneus longus (PL), and semitendinosus (ST). We hypothesized that allograft properties would be similar when standardized by the looped diameter. Controlled laboratory study. This study consisted of 2 arms evaluating large and small looped-diameter grafts: experiment A consisted of TA, TP, and PL tendons (n = 47 each) with larger looped diameters of 9.0 to 9.5 mm, and experiment B consisted of TA, TP, PL, and ST tendons (n = 53 each) with smaller looped diameters of 7.0 to 7.5 mm. Each specimen underwent mechanical testing to measure the modulus of elasticity (E), ultimate tensile force (UTF), maximal elongation at failure, ultimate tensile stress (UTS), and ultimate tensile strain (UTε). Experiment A: No significant differences were noted among tendons for UTF, maximal elongation at failure, and UTϵ. UTS was significantly higher for the PL (54 MPa) compared with the TA (44 MPa) and TP (43 MPa) tendons. E was significantly higher for the PL (501 MPa) compared with the TP (416 MPa) tendons. Equivalence testing showed that the TP and PL tendon properties were equivalent or superior to those of the TA tendons for all outcomes. Experiment B: All groups exhibited a similar E. UTF was again highest in the PL tendons (2294 N) but was significantly different from only the ST tendons (1915 N). UTϵ was significantly higher for the ST (0.22) compared with the TA (0.19) and TP (0.19) tendons. Equivalence testing showed that the TA, TP, and PL tendon properties were equivalent or superior to those of the ST tendons. Compared with TA tendons, TP and PL tendons of a given looped diameter exhibited noninferior initial biomechanical strength and stiffness characteristics. ST tendons were mostly similar to TA tendons but exhibited a significantly higher elongation/UTϵ and smaller cross-sectional area. For smaller looped-diameter grafts, all tissues were noninferior to ST tendons. In contrast to previous findings, PL tendons proved to be equally strong. The results of this study should encourage surgeons to use these soft tissue allografts interchangeably, which is important as the number of ligament reconstructions performed with allografts continues to rise.

  19. Calf Endurance and Achilles Tendon Structure in Classical Ballet Dancers.

    PubMed

    Zellers, Jennifer A; van Ostrand, Katrina; Silbernagel, Karin Grävare

    2017-06-15

    Optimal lower leg function is critical for ballet dancers to meet their occupational requirements. Achilles tendon injury is particularly detrimental to ballet dancers. While standardized measures have been validated and incorporated into clinical practice for use in people with Achilles tendon injury, normative ranges specific to the dancer population have not been described. The purpose of this pilot study was to observe the performance of pre-professional ballet students and professional ballet dancers on a well-established test battery for lower leg functional performance as well as ultra-sonographic evaluation of the structure of their Achilles tendons. The dancers in this study had significantly shorter Achilles tendons than non-dancers (p = 0.016). Dancers demonstrated significantly higher maximum heel-rise height on the heel-rise test for calf endurance (p < 0.001) but performed significantly less work than non-dancers (p = 0.014). The results of this study support the use of the heel-rise test as a tool for screening and to guide rehabilitation.

  20. Functional tissue engineering of tendon: Establishing biological success criteria for improving tendon repair.

    PubMed

    Breidenbach, Andrew P; Gilday, Steven D; Lalley, Andrea L; Dyment, Nathaniel A; Gooch, Cynthia; Shearn, Jason T; Butler, David L

    2014-06-27

    Improving tendon repair using Functional Tissue Engineering (FTE) principles has been the focus of our laboratory over the last decade. Although our primary goals were initially focused only on mechanical outcomes, we are now carefully assessing the biological properties of our tissue-engineered tendon repairs so as to link biological influences with mechanics. However, given the complexities of tendon development and healing, it remains challenging to determine which aspects of tendon biology are the most important to focus on in the context of tissue engineering. To address this problem, we have formalized a strategy to identify, prioritize, and evaluate potential biological success criteria for tendon repair. We have defined numerous biological properties of normal tendon relative to cellular phenotype, extracellular matrix and tissue ultra-structure that we would like to reproduce in our tissue-engineered repairs and prioritized these biological criteria by examining their relative importance during both normal development and natural tendon healing. Here, we propose three specific biological criteria which we believe are essential for normal tendon function: (1) scleraxis-expressing cells; (2) well-organized and axially-aligned collagen fibrils having bimodal diameter distribution; and (3) a specialized tendon-to-bone insertion site. Moving forward, these biological success criteria will be used in conjunction with our already established mechanical success criteria to evaluate the effectiveness of our tissue-engineered tendon repairs. © 2013 Published by Elsevier Ltd.

  1. Characterising the proximal patellar tendon attachment and its relationship to skeletal maturity in adolescent ballet dancers

    PubMed Central

    Rudavsky, Aliza; Cook, Jillianne; Magnusson, Stig Peter; Kjaer, Michael; Docking, Sean

    2017-01-01

    Summary Background It is unknown how and when the proximal attachment of the patellar tendon matures; puberty may be key in ensuring normal tendon formation. The aim of this study was to investigate the features of the proximal patellar tendon attachment at different stages of skeletal maturity, to help gain an understanding of how and when the tendon attachment matures. Methods Sixty adolescent elite ballet students (ages 11–18) and eight mature adults participated. Peak height velocity (PHV) estimated skeletal maturity. Ultrasound tissue characterisation (UTC) scan was taken of the left knee and analysed for stability of echopattern. An image-based grading scale for greyscale ultrasound was developed to describe the tendon appearance. Anterior-posterior thickness was measured at the inferior pole of the patella, 1 and 2 centimetres distally. Outcomes were compared with skeletal maturity. Results Mid-portion patellar tendon thickness increased with skeletal maturity (p=0.001 at 1 cm and p=0.007 at 2 cm). There was more variance in structural appearance (greyscale classification and UTC echopattern) in pre and peri-PHV participants. Tendon attachment one-year post PHV appeared similar to mature tendons. Conclusions Early adolescence was associated with highly variable tendon appearance, whereas the tendon appeared mature after PHV. Adolescence may be a critical time for the formation of normal tendon attachment. Level of evidence IIb individual cohort study. PMID:29264342

  2. It's positive to be negative: Achilles tendon work loops during human locomotion.

    PubMed

    Zelik, Karl E; Franz, Jason R

    2017-01-01

    Ultrasound imaging is increasingly used with motion and force data to quantify tendon dynamics during human movement. Frequently, tendon dynamics are estimated indirectly from muscle fascicle kinematics (by subtracting muscle from muscle-tendon unit length), but there is mounting evidence that this Indirect approach yields implausible tendon work loops. Since tendons are passive viscoelastic structures, when they undergo a loading-unloading cycle they must exhibit a negative work loop (i.e., perform net negative work). However, prior studies using this Indirect approach report large positive work loops, often estimating that tendons return 2-5 J of elastic energy for every 1 J of energy stored. More direct ultrasound estimates of tendon kinematics have emerged that quantify tendon elongations by tracking either the muscle-tendon junction or localized tendon tissue. However, it is unclear if these yield more plausible estimates of tendon dynamics. Our objective was to compute tendon work loops and hysteresis losses using these two Direct tendon kinematics estimates during human walking. We found that Direct estimates generally resulted in negative work loops, with average tendon hysteresis losses of 2-11% at 1.25 m/s and 33-49% at 0.75 m/s (N = 8), alluding to 0.51-0.98 J of tendon energy returned for every 1 J stored. We interpret this finding to suggest that Direct approaches provide more plausible estimates than the Indirect approach, and may be preferable for understanding tendon energy storage and return. However, the Direct approaches did exhibit speed-dependent trends that are not consistent with isolated, in vitro tendon hysteresis losses of about 5-10%. These trends suggest that Direct estimates also contain some level of error, albeit much smaller than Indirect estimates. Overall, this study serves to highlight the complexity and difficulty of estimating tendon dynamics non-invasively, and the care that must be taken to interpret biological function from current ultrasound-based estimates.

  3. Anatomy, function, and pathophysiology of the posterior tibial tendon.

    PubMed

    Smith, C F

    1999-07-01

    The posterior tibial tendon is vital for the structure and function of the foot and ankle. Dysfunction of the tendon can be debilitating and devastating. In recent years, much attention had been directed toward the diagnosis and treatment of PTTD. To properly diagnose and devise an appropriate treatment regimen, the anatomy, function, and pathophysiology associated with PTTD need to be thoroughly understood.

  4. Neuronal regulation of tendon homoeostasis

    PubMed Central

    Ackermann, Paul W

    2013-01-01

    The regulation of tendon homoeostasis, including adaptation to loading, is still not fully understood. Accumulating data, however, demonstrates that in addition to afferent (sensory) functions, the nervous system, via efferent pathways which are associated with through specific neuronal mediators plays an active role in regulating pain, inflammation and tendon homeostasis. This neuronal regulation of intact-, healing- and tendinopathic tendons has been shown to be mediated by three major groups of molecules including opioid, autonomic and excitatory glutamatergic neuroregulators. In intact healthy tendons the neuromediators are found in the surrounding structures: paratenon, endotenon and epitenon, whereas the proper tendon itself is practically devoid of neurovascular supply. This neuroanatomy reflects that normal tendon homoeostasis is regulated from the tendon surroundings. After injury and during tendon repair, however, there is extensive nerve ingrowth into the tendon proper, followed by a time-dependent emergence of sensory, autonomic and glutamatergic mediators, which amplify and fine-tune inflammation and regulate tendon regeneration. In tendinopathic condition, excessive and protracted presence of sensory and glutamatergic neuromediators has been identified, suggesting involvement in inflammatory, nociceptive and hypertrophic (degenerative) tissue responses. Under experimental and clinical conditions of impaired (e.g. diabetes) as well as excessive (e.g. tendinopathy) neuromediator release, dysfunctional tendon homoeostasis develops resulting in chronic pain and gradual degeneration. Thus there is a prospect that in the future pharmacotherapy and tissue engineering approaches targeting neuronal mediators and their receptors may prove to be effective therapies for painful, degenerative and traumatic tendon disorders. PMID:23718724

  5. Scleraxis is required for cell lineage differentiation and extracellular matrix remodeling during murine heart valve formation in vivo.

    PubMed

    Levay, Agata K; Peacock, Jacqueline D; Lu, Yinhui; Koch, Manuel; Hinton, Robert B; Kadler, Karl E; Lincoln, Joy

    2008-10-24

    Heart valve structures, derived from mesenchyme precursor cells, are composed of differentiated cell types and extracellular matrix arranged to facilitate valve function. Scleraxis (scx) is a transcription factor required for tendon cell differentiation and matrix organization. This study identified high levels of scx expression in remodeling heart valve structures at embryonic day 15.5 through postnatal stages using scx-GFP reporter mice and determined the in vivo function using mice null for scx. Scx(-/-) mice display significantly thickened heart valve structures from embryonic day 17.5, and valves from mutant mice show alterations in valve precursor cell differentiation and matrix organization. This is indicated by decreased expression of the tendon-related collagen type XIV, increased expression of cartilage-associated genes including sox9, as well as persistent expression of mesenchyme cell markers including msx1 and snai1. In addition, ultrastructure analysis reveals disarray of extracellular matrix and collagen fiber organization within the valve leaflet. Thickened valve structures and increased expression of matrix remodeling genes characteristic of human heart valve disease are observed in juvenile scx(-/-) mice. In addition, excessive collagen deposition in annular structures within the atrioventricular junction is observed. Collectively, our studies have identified an in vivo requirement for scx during valvulogenesis and demonstrate its role in cell lineage differentiation and matrix distribution in remodeling valve structures.

  6. Influence of residual composition on the structure and properties of extracellular matrix derived hydrogels.

    PubMed

    Claudio-Rizo, Jesús A; Rangel-Argote, Magdalena; Castellano, Laura E; Delgado, Jorge; Mata-Mata, José L; Mendoza-Novelo, Birzabith

    2017-10-01

    In this work, hydrolysates of extracellular matrix (hECM) were obtained from rat tail tendon (TR), bovine Achilles tendon (TAB), porcine small intestinal submucosa (SIS) and bovine pericardium (PB), and they were polymerized to generate ECM hydrogels. The composition of hECM was evaluated by quantifying the content of sulphated glycosaminoglycans (sGAG), fibronectin and laminin. The polymerization process, structure, physicochemical properties, in vitro degradation and biocompatibility were studied and related to their composition. The results indicated that the hECM derived from SIS and PB were significantly richer in sGAG, fibronectin and laminin, than those derived from TAB and TR. These differences in hECM composition influenced the polymerization and the structural characteristics of the fibrillar gel network. Consequently, the swelling, mechanics and degradation of the hydrogels showed a direct relationship with the remaining composition. Moreover, the cytocompatibility and the secretion of transforming growth factor beta-1 (TGF-β1) by macrophages were enhanced in hydrogels with the highest residual content of ECM biomolecules. The results of this work evidenced the role of the ECM molecules remaining after both decellularization and hydrolysis steps to produce tissue derived hydrogels with structure and properties tailored to enhance their performance in tissue engineering and regenerative medicine applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Micro-mechanical properties of the tendon-to-bone attachment.

    PubMed

    Deymier, Alix C; An, Yiran; Boyle, John J; Schwartz, Andrea G; Birman, Victor; Genin, Guy M; Thomopoulos, Stavros; Barber, Asa H

    2017-07-01

    The tendon-to-bone attachment (enthesis) is a complex hierarchical tissue that connects stiff bone to compliant tendon. The attachment site at the micrometer scale exhibits gradients in mineral content and collagen orientation, which likely act to minimize stress concentrations. The physiological micromechanics of the attachment thus define resultant performance, but difficulties in sample preparation and mechanical testing at this scale have restricted understanding of structure-mechanical function. Here, microscale beams from entheses of wild type mice and mice with mineral defects were prepared using cryo-focused ion beam milling and pulled to failure using a modified atomic force microscopy system. Micromechanical behavior of tendon-to-bone structures, including elastic modulus, strength, resilience, and toughness, were obtained. Results demonstrated considerably higher mechanical performance at the micrometer length scale compared to the millimeter tissue length scale, describing enthesis material properties without the influence of higher order structural effects such as defects. Micromechanical investigation revealed a decrease in strength in entheses with mineral defects. To further examine structure-mechanical function relationships, local deformation behavior along the tendon-to-bone attachment was determined using local image correlation. A high compliance zone near the mineralized gradient of the attachment was clearly identified and highlighted the lack of correlation between mineral distribution and strain on the low-mineral end of the attachment. This compliant region is proposed to act as an energy absorbing component, limiting catastrophic failure within the tendon-to-bone attachment through higher local deformation. This understanding of tendon-to-bone micromechanics demonstrates the critical role of micrometer scale features in the mechanics of the tissue. The tendon-to-bone attachment (enthesis) is a complex hierarchical tissue with features at a numerous scales that dissipate stress concentrations between compliant tendon and stiff bone. At the micrometer scale, the enthesis exhibits gradients in collagen and mineral composition and organization. However, the physiological mechanics of the enthesis at this scale remained unknown due to difficulty in preparing and testing micrometer scale samples. This study is the first to measure the tensile mechanical properties of the enthesis at the micrometer scale. Results demonstrated considerably enhanced mechanical performance at the micrometer length scale compared to the millimeter tissue length scale and identified a high-compliance zone near the mineralized gradient of the attachment. This understanding of tendon-to-bone micromechanics demonstrates the critical role of micrometer scale features in the mechanics of the tissue. Copyright © 2017. Published by Elsevier Ltd.

  8. Postinjury biomechanics of Achilles tendon vary by sex and hormone status

    PubMed Central

    Fryhofer, George W.; Freedman, Benjamin R.; Hillin, Cody D.; Salka, Nabeel S.; Pardes, Adam M.; Weiss, Stephanie N.; Farber, Daniel C.

    2016-01-01

    Achilles tendon ruptures are common injuries. Sex differences are present in mechanical properties of uninjured Achilles tendon, but it remains unknown if these differences extend to tendon healing. We hypothesized that ovariectomized females (OVX) and males would exhibit inferior postinjury tendon properties compared with females. Male, female, and OVX Sprague-Dawley rats (n = 32/group) underwent acclimation and treadmill training before blunt transection of the Achilles tendon midsubstance. Injured hindlimbs were immobilized for 1 wk, followed by gradual return to activity and assessment of active and passive hindlimb function. Animals were euthanized at 3 or 6 wk postinjury to assess tendon structure, mechanics, and composition. Passive ankle stiffness and range of motion were superior in females at 3 wk; however, by 6 wk, passive and active function were similar in males and females but remained inferior in OVX. At 6 wk, female tendons had greater normalized secant modulus, viscoelastic behavior, and laxity compared with males. Normalized secant modulus, cross-sectional area and tendon glycosaminoglycan composition were inferior in OVX compared with females at 6 wk. Total fatigue cycles until tendon failure were similar among groups. Postinjury muscle fiber size was better preserved in females compared with males, and females had greater collagen III at the tendon injury site compared with males at 6 wk. Despite male and female Achilles tendons withstanding similar durations of fatigue loading, early passive hindlimb function and tendon mechanical properties, including secant modulus, suggest superior healing in females. Ovarian hormone loss was associated with inferior Achilles tendon healing. PMID:27633741

  9. Informing Stem Cell-Based Tendon Tissue Engineering Approaches with Embryonic Tendon Development.

    PubMed

    Okech, William; Kuo, Catherine K

    Adult tendons fail to regenerate normal tissue after injury, and instead form dysfunctional scar tissue with abnormal mechanical properties. Surgical repair with grafts is the current standard to treat injuries, but faces significant limitations including pain and high rates of re-injury. To address this, we aim to regenerate new, normal tendons to replace dysfunctional tendons. A common approach to tendon tissue engineering is to design scaffolds and bioreactors based on adult tendon properties that can direct adult stem cell tenogenesis. Despite significant progress, advances have been limited due, in part, to a need for markers and potent induction cues. Our goal is to develop novel tendon tissue engineering approaches informed by embryonic tendon development. We are characterizing structure-property relationships of embryonic tendon to identify design parameters for three-dimensional scaffolds and bioreactor mechanical loading systems to direct adult stem cell tenogenesis. We will review studies in which we quantified changes in the mechanical and biochemical properties of tendon during embryonic development and elucidated specific mechanisms of functional property elaboration. We then examined the effects of these mechanical and biochemical factors on embryonic tendon cell behavior. Using custom-designed bioreactors, we also examined the effects of dynamic mechanical loading and growth factor treatment on embryonic tendon cells. Our findings have established cues to induce tenogenesis as well as metrics to evaluate differentiation. We finish by discussing how we have evaluated the tenogenic differentiation potential of adult stem cells by comparing their responses to that of embryonic tendon cells in these culture systems.

  10. Quantitative tissue parameters of Achilles tendon and plantar fascia in healthy subjects using a handheld myotonometer.

    PubMed

    Orner, Sarah; Kratzer, Wolfgang; Schmidberger, Julian; Grüner, Beate

    2018-01-01

    The aim of the study was to examine the quantitative tissue properties of the Achilles tendon and plantar fascia using a handheld, non-invasive MyotonPRO device, in order to generate normal values and examine the biomechanical relationship of both structures. Prospective study of a large, healthy sample population. The study sample included 207 healthy subjects (87 males and 120 females) for the Achilles tendon and 176 healthy subjects (73 males and 103 females) for the plantar fascia. For the correlations of the tissue parameters of the Achilles tendon and plantar fascia an intersection of both groups was formed which included 150 healthy subjects (65 males and 85 females). All participants were measured in a prone position. Consecutive measurements of the Achilles tendon and plantar fascia were performed by MyotonPRO device at defined sites. For the left and right Achilles tendons and plantar fasciae all five MyotonPRO parameters (Frequency [Hz], Decrement, Stiffness [N/m], Creep and Relaxation Time [ms]) were calculated of healthy males and females. The correlation of the tissue parameters of the Achilles tendon and plantar fascia showed a significant positive correlation of all parameters on the left as well as on the right side. The MyotonPRO is a feasible device for easy measurement of passive tissue properties of the Achilles tendon and plantar fascia in a clinical setting. The generated normal values of the Achilles tendon and plantar fascia are important for detecting abnormalities in patients with Achilles tendinopathy or plantar fasciitis in the future. Biomechanically, both structures are positively correlated. This may provide new aspects in the diagnostics and therapy of plantar fasciitis and Achilles tendinopathy. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Basic Study and Clinical Implications of Left Ventricular False Tendon. Is it Associated With Innocent Murmur in Children or Heart Disease?

    PubMed

    Sánchez Ferrer, Francisco; Sánchez Ferrer, María Luisa; Grima Murcia, María Dolores; Sánchez Ferrer, Marina; Sánchez del Campo, Francisco

    2015-08-01

    Left ventricular false tendon is a structure of unknown function in cardiac physiology that was first described anatomically by Turner. This condition may be related to various electrical or functional abnormalities, but no consensus has ever been reached. The purpose of this study was to determine the time of appearance, prevalence and histologic composition of false tendon, as well as its association with innocent murmur in children and with heart disease. The basic research was performed by anatomic dissection of hearts from adult human cadavers to describe false tendon and its histology. The clinical research consisted of echocardiographic study in a pediatric population to identify any relationship with heart disease, innocent murmur in children, or other abnormalities. Fetal echocardiography was performed prenatally at different gestational ages. False tendon was a normal finding in cardiac dissection and was composed of muscle and connective tissue fibers. In the pediatric population, false tendon was present in 83% on echocardiography and showed a statistically significant association only with innocent murmur in children and slower aortic acceleration. The presence of false tendon was first observed on fetal echocardiography from week 20 of pregnancy. Left ventricular false tendon is a normal finding visualized by fetal echocardiography from week 20 and is present until adulthood with no pathologic effects except for innocent murmur during childhood. It remains to be determined if false tendon is the cause of the murmurs or if its absence or structural anomalies are related to disease. Copyright © 2014 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  12. Functional grading of mineral and collagen in the attachment of tendon to bone.

    PubMed

    Genin, Guy M; Kent, Alistair; Birman, Victor; Wopenka, Brigitte; Pasteris, Jill D; Marquez, Pablo J; Thomopoulos, Stavros

    2009-08-19

    Attachment of dissimilar materials is a major challenge because high levels of localized stress may develop at their interfaces. An effective biologic solution to this problem exists at one of nature's most extreme interfaces: the attachment of tendon (a compliant, structural "soft tissue") to bone (a stiff, structural "hard tissue"). The goal of our study was to develop biomechanical models to describe how the tendon-to-bone insertion derives its mechanical properties. We examined the tendon-to-bone insertion and found two factors that give the tendon-to-bone transition a unique grading in mechanical properties: 1), a gradation in mineral concentration, measured by Raman spectroscopy; and 2), a gradation in collagen fiber orientation, measured by polarized light microscopy. Our measurements motivate a new physiological picture of the tissue that achieves this transition, the tendon-to-bone insertion, as a continuous, functionally graded material. Our biomechanical model suggests that the experimentally observed increase in mineral accumulation within collagen fibers can provide significant stiffening of the partially mineralized fibers, but only for concentrations of mineral above a "percolation threshold" corresponding to formation of a mechanically continuous mineral network within each collagen fiber (e.g., the case of mineral connectivity extending from one end of the fiber to the other). Increasing dispersion in the orientation distribution of collagen fibers from tendon to bone is a second major determinant of tissue stiffness. The combination of these two factors may explain the nonmonotonic variation of stiffness over the length of the tendon-to-bone insertion reported previously. Our models explain how tendon-to-bone attachment is achieved through a functionally graded material composition, and provide targets for tissue engineered surgical interventions and biomimetic material interfaces.

  13. Landing strategies of athletes with an asymptomatic patellar tendon abnormality.

    PubMed

    Edwards, Suzi; Steele, Julie R; McGhee, Deirdre E; Beattie, Sue; Purdam, Craig; Cook, Jill L

    2010-11-01

    Risk factors associated with a clinical presentation of patellar tendinopathy are patellar tendon ultrasonographic abnormality (PTA) and excessive loading. It remains unknown whether characteristics of an athlete's landing technique contribute to this excessive patellar tendon loading. This study investigated whether asymptomatic athletes with and without PTA had different landing strategies and hypothesized that asymptomatic athletes with a PTA would create higher patellar tendon loading and a different lower-limb landing strategy compared with athletes with normal patellar tendons. Seven athletes with no previous history or clinical signs of patellar tendon injury with a PTA were matched to athletes with normal patellar tendons (controls). Participants performed five successful trials of a stop-jump task, which involved a simultaneous two-foot horizontal and then vertical landing. During each trial, the participants' ground reaction forces and lower-limb electromyographic data were recorded, the three-dimensional kinematics measured, and the peak patellar tendon force calculated by dividing the net knee joint moment by the patellar tendon moment arm. Significant between-group differences in landing technique were mostly observed during the horizontal landing phase. Participants with a PTA created similar patellar tendon loading to the controls, but with altered sequencing, by landing with significantly greater knee flexion and extending their hips while the controls flexed their hips as they landed, reflecting a different muscle recruitment order compared with the PTA group. The crucial part in the development of PTA and, in turn, patellar tendinopathy may not be the magnitude of the patellar tendon load but rather the loading patterns. This research provides clinicians with important landing assessment criteria against which to identify athletes at risk of developing patellar tendinopathy.

  14. Synovial Mesenchymal Stem Cells Promote Meniscus Regeneration Augmented by an Autologous Achilles Tendon Graft in a Rat Partial Meniscus Defect Model

    PubMed Central

    Ozeki, Nobutake; Muneta, Takeshi; Matsuta, Seiya; Koga, Hideyuki; Nakagawa, Yusuke; Mizuno, Mitsuru; Tsuji, Kunikazu; Mabuchi, Yo; Akazawa, Chihiro; Kobayashi, Eiji; Saito, Tomoyuki; Sekiya, Ichiro

    2015-01-01

    Although meniscus defects and degeneration are strongly correlated with the later development of osteoarthritis, the promise of regenerative medicine strategies is to prevent and/or delay the disease's progression. Meniscal reconstruction has been shown in animal models with tendon grafting and transplantation of mesenchymal stem cells (MSCs); however, these procedures have not shown the same efficacy in clinical studies. Here, our aim was to investigate the ability of tendon grafts pretreated with exogenous synovial-derived MSCs to prevent cartilage degeneration in a rat partial meniscus defect model. We removed the anterior half of the medial meniscus and grafted autologous Achilles tendons with or without a 10-minute pretreatment of the tendon with synovial MSCs. The meniscus and surrounding cartilage were evaluated at 2, 4, and 8 weeks (n = 5). Tendon grafts increased meniscus size irrespective of synovial MSCs. Histological scores for regenerated menisci were better in the tendon + MSC group than in the other two groups at 4 and 8 weeks. Both macroscopic and histological scores for articular cartilage were significantly better in the tendon + MSC group at 8 weeks. Implanted synovial MSCs survived around the grafted tendon and native meniscus integration site by cell tracking assays with luciferase+, LacZ+, DiI+, and/or GFP+ synovial MSCs and/or GFP+ tendons. Flow cytometric analysis showed that transplanted synovial MSCs retained their MSC properties at 7 days and host synovial tissue also contained cells with MSC characteristics. Synovial MSCs promoted meniscus regeneration augmented by autologous Achilles tendon grafts and prevented cartilage degeneration in rats. Stem Cells 2015;33:1927–1938 PMID:25993981

  15. Extracorporeal shock waves promote healing of collagenase-induced Achilles tendinitis and increase TGF-beta1 and IGF-I expression.

    PubMed

    Chen, Yeung-Jen; Wang, Ching-Jen; Yang, Kuender D; Kuo, Yur-Ren; Huang, Hui-Chen; Huang, Yu-Ting; Sun, Yi-Chih; Wang, Feng-Sheng

    2004-07-01

    Extracorporeal shock waves (ESW) have recently been used in resolving tendinitis. However, mechanisms by which ESW promote tendon repair is not fully understood. In this study, we reported that an optimal ESW treatment promoted healing of Achilles tendintis by inducing TGF-beta1 and IGF-I. Rats with the collagenease-induced Achilles tendinitis were given a single ESW treatment (0.16 mJ/mm(2) energy flux density) with 0, 200, 500 and 1000 impulses. Achilles tendons were subjected to biomechanical (load to failure and stiffness), biochemical properties (DNA, glycosaminoglycan and hydroxyproline content) and histological assessment. ESW with 200 impulses restored biomechanical and biochemical characteristics of healing tendons 12 weeks after treatment. However, ESW treatments with 500 and 1000 impulses elicited inhibitory effects on tendinitis repair. Histological observation demonstrated that ESW treatment resolved edema, swelling, and inflammatory cell infiltration in injured tendons. Lesion site underwent intensive tenocyte proliferation, neovascularization and progressive tendon tissue regeneration. Tenocytes at the hypertrophied cellular tissue and newly developed tendon tissue expressed strong proliferating cell nuclear antigen (PCNA) after ESW treatment, suggesting that physical ESW could increase the mitogenic responses of tendons. Moreover, the proliferation of tenocytes adjunct to hypertrophied cell aggregate and newly formed tendon tissue coincided with intensive TGF-beta1 and IGF-I expression. Increasing TGF-beta1 expression was noted in the early stage of tendon repair, and elevated IGF-I expression was persisted throughout the healing period. Together, low-energy shock wave effectively promoted tendon healing. TGF-beta1 and IGF-I played important roles in mediating ESW-stimulated cell proliferation and tissue regeneration of tendon.

  16. Fascicles and the interfascicular matrix show decreased fatigue life with ageing in energy storing tendons.

    PubMed

    Thorpe, Chavaunne T; Riley, Graham P; Birch, Helen L; Clegg, Peter D; Screen, Hazel R C

    2017-07-01

    Tendon is composed of rope-like fascicles bound together by interfascicular matrix (IFM). The IFM is critical for the function of energy storing tendons, facilitating sliding between fascicles to allow these tendons to cyclically stretch and recoil. This capacity is required to a lesser degree in positional tendons. We have previously demonstrated that both fascicles and IFM in energy storing tendons have superior fatigue resistance compared with positional tendons, but the effect of ageing on the fatigue properties of these different tendon subunits has not been determined. Energy storing tendons become more injury-prone with ageing, indicating reduced fatigue resistance, hence we tested the hypothesis that the decline in fatigue life with ageing in energy storing tendons would be more pronounced in the IFM than in fascicles. We further hypothesised that tendon subunit fatigue resistance would not alter with ageing in positional tendons. Fascicles and IFM from young and old energy storing and positional tendons were subjected to cyclic fatigue testing until failure, and mechanical properties were calculated. The results show that both IFM and fascicles from the SDFT exhibit a similar magnitude of reduced fatigue life with ageing. By contrast, the fatigue life of positional tendon subunits was unaffected by ageing. The age-related decline in fatigue life of tendon subunits in energy storing tendons is likely to contribute to the increased risk of injury in aged tendons. Full understanding of the mechanisms resulting in this reduced fatigue life will aid in the development of treatments and interventions to prevent age-related tendinopathy. Understanding the effect of ageing on tendon-structure function relationships is crucial for the development of effective preventative measures and treatments for age-related tendon injury. In this study, we demonstrate for the first time that the fatigue resistance of the interfascicular matrix decreases with ageing in energy storing tendons. This is likely to contribute to the increased risk of injury in aged tendons. Full understanding of the mechanisms that result in this reduced fatigue resistance will aid in the development of treatments and interventions to prevent age-related tendinopathy. Copyright © 2017. Published by Elsevier Ltd.

  17. [Clinical application of peroneal muscles tendon transposition in repair of Achilles tendon rupture].

    PubMed

    Jin, Rihao; Jin, Yu; Fang, Xiulin

    2006-07-01

    To discuss applied anatomy, biomechanics and surgical procedures of long peroneal muscles tendon transposition in repair of occlusive achilles tendon rupture. The blood supply and the morphology of long peroneal muscles tendon were observed in the lower extremity of 50 sides adult specimens and the mechanical tests which stretch load on the tendon were carried out. The methods were designed on the basis of the anatomical characteristics and morphology. Ten patients suffering occlusive Achilles tendon rupture were treated by using long peroneal muscles tendon transposition from March 2001 to July 2004. Among 10 patients, there were 7 males and 3 females, aging 32 to 54 years including 6 cases of jump injury, 2 cases of bruise, 1 case of step vacancy and 1 case of spontaneity injury. The interval between injury and surgery was 6 hours to 7 days in 7 fresh rupture and 21 days to 3 months in 3 old rupture. All cases belonged to occlusive Achilles tendon rupture (8 cases of complete rupture and 2 cases of incomplete rupture). The origin of long peroneal muscles was proximal tibia and fibular head, the end of them was base of first metatarsal bones and medial cuboid. The length of tendon was 13.5 +/- 2.5 cm. The width of origin tendon was 0.9 +/- 0.2 cm and the thickness was 0.3 +/- 0.1 cm; the width on apex of lateral malleolus was 0.7 +/- 0.1 cm and the thickness was 0.4 +/- 0.1 cm, the width on head of cuboid was 0.7 +/- 0.1 cm and the thickness was 0.3 +/- 0.1 cm. The long peroneal muscles tendon had abundant blood supply. The results of mechanical test showed that the biggest load was 2,292.4 +/- 617.3 N on tendon calcaneus, 1,020.4 +/- 175.4 N on long peroneal muscles tendon, 752.0 +/- 165.4 N on peroneus brevis tendon and 938.2 +/- 216.7 N on tibialis posterior tendon. Ten cases of occlusive Achilles tendon rupture achieved healing by first intention and were followed up 18-24 months. No Achilles tendon re-rupture, necrosis of skin or other complications occurred. According to Amerind-holm criterion for curative results, the results were excellent in 7 cases and good in 3 cases and the excellent and good rate was 100%. The long peroneal muscles tendon transposition is a perfect and simple way to repair occlusive Achilles tendon rupture.

  18. Changes in type I collagen following laser welding.

    PubMed

    Bass, L S; Moazami, N; Pocsidio, J; Oz, M C; LoGerfo, P; Treat, M R

    1992-01-01

    Selection of ideal laser parameters for tissue welding is inhibited by poor understanding of the mechanism. We investigated structural changes in collagen molecules extracted from rat tail tendon (> 90% type I collagen) after tissue welding using an 808 nm diode laser and indocyanine green dye applied to the weld site. Mobility patterns on SDS-PAGE were identical in the lasered and untreated tendon extracts with urea or acetic acid. Pepsin incubation after acetic acid extraction revealed a reduction of collagen alpha and beta bands in lasered compared with untreated specimens. Circular dichroism studies of rat tail tendon showed absence of helical structure in collagen from lasered tendon. No evidence for covalent bonding was present in laser-treated tissues. Collagen molecules are denatured by the laser wavelength and parameters used in this study. No significant amount of helical structure is regenerated on cooling. We conclude that non-covalent interactions between denatured collagen molecules may be responsible for the creation of tissue welding.

  19. Health monitoring of prestressing tendons in post-tensioned concrete structures

    NASA Astrophysics Data System (ADS)

    Salamone, Salvatore; Bartoli, Ivan; Nucera, Claudio; Phillips, Robert; Lanza di Scalea, Francesco

    2011-04-01

    Currently 90% of bridges built in California are post-tensioned box-girder. In such structures the steel tendons are the main load-carrying components. The loss of prestress, as well as the presence of defects or the tendon breakage, can be catastrophic for the entire structure. Unfortunately, today there is no well-established method for the monitoring of prestressing (PS) tendons that can provide simultaneous information related to the presence of defects and the level of prestress in a continuous, real time manner. If such a monitoring system were available, considerable savings would be achieved in bridge maintenance since repairs would be implemented in a timely manner without traffic disruptions. This paper presents a health monitoring system for PS tendons in post-tensioned structures of interest to Caltrans. Such a system uses ultrasonic guided waves and embedded sensors to provide simultaneously and in real time, (a) measurements of the level of applied prestress, and (b) defect detection at early grow stages. The proposed PS measurement technique exploits the sensitivity of ultrasonic waves to the inter-wire contact developing in a multi-wire strand as a function of prestress level. In particular the nonlinear ultrasonic behavior of the tendon under changing levels of prestress is monitored by tracking higher-order harmonics at (nω) arising under a fundamental guided-wave excitation at (ω). Moreover this paper also present real-time damage detection and location in post-tensioned bridge joints using Acoustic Emission techniques. Experimental tests on large-scale single-tendon PT joint specimens, subjected to multiple load cycles, will be presented to validate the monitoring of PS loads (through nonlinear ultrasonic probing) and the monitoring of damage progression and location (through acoustic emission techniques). Issues and potential for the use of such techniques to monitor post-tensioned bridges in the field will be discussed.

  20. Fixation of the Achilles tendon insertion using suture button technology.

    PubMed

    Fanter, Nathan J; Davis, Edward W; Baker, Champ L

    2012-09-01

    In the operative treatment of Achilles insertional tendinopathy, no guidelines exist concerning which form of fixation of the Achilles tendon insertion is superior. Transcalcaneal drill pin passage does not place any major plantar structures at risk, and the addition of a Krackow stitch and suture button to the fixation technique provides a significant increase in ultimate load to failure in Achilles tendon insertional repairs. Controlled laboratory study. The Achilles tendon insertions in 6 fresh-frozen cadaveric ankles were detached, and transcalcaneal drill pins were passed. Plantar dissection took place to evaluate the drill pin relationship to the plantar fascia, lateral plantar nerve and artery, flexor digitorum longus tendon, and master knot of Henry. The Achilles tendons were then repaired with a double-row suture anchor construct alone or with a suture button and Krackow stitch added to the double-row suture anchor construct. The repairs were then tested to maximum load to failure at 20 mm/min. The mode of failure was recorded, and the mean maximum load to failure was assessed using the Student t test for distributions with equal variance. Transcalcaneal drill pin passage did not place any selected anatomic structures at risk. The mean maximum load to failure for the suture bridge group was 239.2 N; it was 391.4 N for the group with the suture button (P = .014). The lateral plantar artery was the structure placed at greatest risk from drill pin placement, with a mean distance of 22.7 mm (range, 16.5-29.2 mm) between the pin and artery. In this laboratory study, transcalcaneal drill pin passage appeared to be anatomically safe, and the use of suture button technology with a Krackow stitch for Achilles tendon insertional repair significantly increased repair strength. Achilles tendon insertional repair with suture button fixation and a Krackow stitch may facilitate the earlier institution of postoperative rehabilitation and improve clinical outcomes.

  1. Use of quantitative analysis of sonographic brightness for detection of early healing of tendon injury in horses.

    PubMed

    Micklethwaite, L; Wood, A K; Sehgal, C M; Polansky, M; Dowling, B A; Dart, A J; Rose, R J; Hodgson, D R

    2001-08-01

    To determine whether quantitative analysis of sonographic brightness could be used to detect healing of an induced injury of the superficial digital flexor tendon in horses and whether rate of healing was influenced by equine recombinant growth hormone. 8 clinically normal Standardbreds. A localized injury was created in the left and right superficial digital flexor tendons of each horse by injection of 2,000 units of collagenase. After injury, 4 horses received equine recombinant growth hormone, a possible promoter of tendon healing. Sonographic images (7.5 MHz) of the flexor tendons and ligaments of the metacarpal region were recorded on videotape prior to injury and weekly for 7 weeks after injury. Images were digitized, and sonographic brightness of tendons and ligaments was calculated. Collagenase-induced injury was sonographically similar to naturally occurring injury. After injury, sonographic brightness of the tendon decreased; after 3 weeks, brightness progressively increased, although by 7 weeks brightness had not returned to preinjury value. Equine recombinant growth hormone had no significant effect on the rate of tendon healing, as evaluated sonographically or at necropsy. As healing developed, alterations in sonographic brightness of injured tendons coincided with real changes in tendon structure. Quantitative sonographic brightness could be used to accurately monitor healing of equine tendon and ligament injuries and investigate the efficacy of various treatment regimens.

  2. THE ROLE OF MECHANOBIOLOGY IN TENDON HEALING

    PubMed Central

    Killian, Megan L.; Cavinatto, Leonardo; Galatz, Leesa M.; Thomopoulos, Stavros

    2011-01-01

    Mechanical cues affect tendon healing, homeostasis, and development in a variety of settings. Alterations in the mechanical environment are known to result in changes in the expression of extracellular matrix proteins, growth factors, transcription factors, and cytokines that can alter tendon structure and cell viability. Loss of muscle force in utero or in the immediate postnatal period delays tendon and enthesis development. The response of healing tendons to mechanical load varies depending on anatomic location. Flexor tendons require motion to prevent adhesion formation, yet excessive force results in gap formation and subsequent weakening of the repair. Excessive motion in the setting of anterior cruciate ligament reconstruction causes accumulation of macrophages, which are detrimental to tendon graft healing. Complete removal of load is detrimental to rotator cuff healing, yet large forces are also harmful. Controlled loading can enhance healing in most settings; however, a fine balance must be reached between loads that are too low (leading to a catabolic state) and too high (leading to micro-damage). This review will summarize existing knowledge of the mechanobiology of tendon development, homeostasis, and healing. PMID:22244066

  3. Cell-laden composite suture threads for repairing damaged tendons.

    PubMed

    Costa-Almeida, Raquel; Domingues, Rui M A; Fallahi, Afsoon; Avci, Huseyin; Yazdi, Iman K; Akbari, Mohsen; Reis, Rui L; Tamayol, Ali; Gomes, Manuela E; Khademhosseini, Ali

    2018-04-01

    Tendons have limited regenerative capacity due to their low cellularity and hypovascular nature, which results in poor clinical outcomes of presently used therapies. As tendon injuries are often observed in active adults, it poses an increasing socio-economic burden on healthcare systems. Currently, suture threads are used during surgical repair to anchor the tissue graft or to connect injured ends. Here, we created composite suture threads coated with a layer of cell-laden hydrogel that can be used for bridging the injured tissue aiming at tendon regeneration. In addition, the fibres can be used to engineer 3-dimensional constructs through textile processes mimicking the architecture and mechanical properties of soft tissues, including tendons and ligaments. Encapsulated human tendon-derived cells migrated within the hydrogel and aligned at the surface of the core thread. An up-regulation of tendon-related genes (scleraxis and tenascin C) and genes involved in matrix remodelling (matrix metalloproteinases 1, matrix metalloproteinases 2) was observed. Cells were able to produce a collagen-rich matrix, remodelling their micro-environment, which is structurally comparable to native tendon tissue. Copyright © 2017 John Wiley & Sons, Ltd.

  4. [Application of silk-based tissue engineering scaffold for tendon / ligament regeneration].

    PubMed

    Hu, Yejun; Le, Huihui; Jin, Zhangchu; Chen, Xiao; Yin, Zi; Shen, Weiliang; Ouyang, Hongwei

    2016-03-01

    Tendon/ligament injury is one of the most common impairments in sports medicine. The traditional treatments of damaged tissue repair are unsatisfactory, especially for athletes, due to lack of donor and immune rejection. The strategy of tissue engineering may break through these limitations, and bring new hopes to tendon/ligament repair, even regeneration. Silk is a kind of natural biomaterials, which has good biocompatibility, wide range of mechanical properties and tunable physical structures; so it could be applied as tendon/ligament tissue engineering scaffolds. The silk-based scaffold has robust mechanical properties; combined with other biological ingredients, it could increase the surface area, promote more cell adhesion and improve the biocompatibility. The potential clinical application of silk-based scaffold has been confirmed by in vivo studies on tendon/ligament repairing, such as anterior cruciate ligament, medial collateral ligament, achilles tendon and rotator cuff. To develop novel biomechanically stable and host integrated tissue engineered tendon/ligament needs more further micro and macro studies, combined with product development and clinical application, which will give new hope to patients with tendon/ligament injury.

  5. Cellular and molecular maturation in fetal and adult ovine calcaneal tendons

    PubMed Central

    Russo, Valentina; Mauro, Annunziata; Martelli, Alessandra; Di Giacinto, Oriana; Di Marcantonio, Lisa; Nardinocchi, Delia; Berardinelli, Paolo; Barboni, Barbara

    2015-01-01

    Processes of development during fetal life profoundly transform tendons from a plastic tissue into a highly differentiated structure, characterised by a very low ability to regenerate after injury in adulthood. Sheep tendon is frequently used as a translational model to investigate cell-based regenerative approaches. However, in contrast to other species, analytical and comparative baseline studies on the normal developmental maturation of sheep tendons from fetal through to adult life are not currently available. Thus, a detailed morphological and biochemical study was designed to characterise tissue maturation during mid- (2 months of pregnancy: 14 cm of length) and late fetal (4 months: 40 cm of length) life, through to adulthood. The results confirm that ovine tendon morphology undergoes profound transformations during this period. Endotenon was more developed in fetal tendons than in adult tissues, and its cell phenotype changed through tendon maturation. Indeed, groups of large rounded cells laying on smaller and more compacted ones expressing osteocalcin, vascular endothelial growth factor (VEGF) and nerve growth factor (NGF) were identified exclusively in fetal mid-stage tissues, and not in late fetal or adult tendons. VEGF, NGF as well as blood vessels and nerve fibers showed decreased expression during tendon development. Moreover, the endotenon of mid- and late fetuses contained identifiable cells that expressed several pluripotent stem cell markers [Telomerase Reverse Transcriptase (TERT), SRY Determining Region Y Box-2 (SOX2), Nanog Homeobox (NANOG) and Octamer Binding Transcription Factor-4A (OCT-4A)]. These cells were not identifiable in adult specimens. Ovine tendon development was also accompanied by morphological modifications to cell nuclei, and a progressive decrease in cellularity, proliferation index and expression of connexins 43 and 32. Tendon maturation was similarly characterised by modulation of several other gene expression profiles, including Collagen type I, Collagen type III, Scleraxis B, Tenomodulin, Trombospondin 4 and Osteocalcin. These gene profiles underwent a dramatic reduction in adult tissues. Transforming growth factor-1 expression (involved in collagen synthesis) underwent a similar decrease. In conclusion, these morphological studies carried out on sheep tendons at different stages of development and aging offer normal structural and molecular baseline data to allow accurate evaluation of data from subsequent interventional studies investigating tendon healing and regeneration in ovine experimental models. PMID:25546075

  6. Effect of Age and Proteoglycan Deficiency on Collagen Fiber Re-Alignment and Mechanical Properties in Mouse Supraspinatus Tendon

    PubMed Central

    Connizzo, Brianne K.; Sarver, Joseph J.; Iozzo, Renato V.; Birk, David E.; Soslowsky, Louis J.

    2013-01-01

    Collagen fiber realignment is one mechanism by which tendon responds to load. Re-alignment is altered when the structure of tendon is altered, such as in the natural process of aging or with alterations of matrix proteins, such as proteoglycan expression. While changes in re-alignment and mechanical properties have been investigated recently during development, they have not been studied in (1) aged tendons, or (2) in the absence of key proteoglycans. Collagen fiber re-alignment and the corresponding mechanical properties are quantified throughout tensile mechanical testing in both the insertion site and the midsubstance of mouse supraspinatus tendons in wild type (WT), decorin-null (Dcn-/-), and biglycan-null (Bgn-/-) mice at three different ages (90 days, 300 days, and 570 days). Percent relaxation was significantly decreased with age in the WT and Dcn-/- tendons, but not in the Bgn-/- tendons. Changes with age were found in the linear modulus at the insertion site where the 300 day group was greater than the 90 day and 570 day group in the Bgn-/- tendons and the 90 day group was smaller than the 300 day and 570 day groups in the Dcn-/- tendons. However, no changes in modulus were found across age in WT tendons were found. The midsubstance fibers of the WT and Bgn-/- tendons were initially less aligned with increasing age. The re-alignment was significantly altered with age in the WT tendons, with older groups responding to load later in the mechanical test. This was also seen in the Dcn-/- midsubstance and the Bgn-/- insertion, but not in the other locations. Although some studies have found changes in the WT mechanical properties with age, this study did not support those findings. However, it did show fiber re-alignment changes at both locations with age, suggesting a breakdown of tendon′s ability to respond to load in later ages. In the proteoglycan-null tendons however, there were changes in the mechanical properties, accompanied only by location-dependent re-alignment changes, suggesting a site-specific role for these molecules in loading. Finally, changes in the mechanical properties did not occur in concert with changes in re-alignment, suggesting that typical mechanical property measurements alone are insufficient to describe how structural alterations affect tendon′s response to load. PMID:23445064

  7. The effects of scaffold architecture and fibrin gel addition on tendon cell phenotype.

    PubMed

    Pawelec, K M; Wardale, R J; Best, S M; Cameron, R E

    2015-01-01

    Development of tissue engineering scaffolds relies on careful selection of pore architecture and chemistry of the cellular environment. Repair of skeletal soft tissue, such as tendon, is particularly challenging, since these tissues have a relatively poor healing response. When removed from their native environment, tendon cells (tenocytes) lose their characteristic morphology and the expression of phenotypic markers. To stimulate tendon cells to recreate a healthy extracellular matrix, both architectural cues and fibrin gels have been used in the past, however, their relative effects have not been studied systematically. Within this study, a combination of collagen scaffold architecture, axial and isotropic, and fibrin gel addition was assessed, using ovine tendon-derived cells to determine the optimal strategy for controlling the proliferation and protein expression. Scaffold architecture and fibrin gel addition influenced tendon cell behavior independently in vitro. Addition of fibrin gel within a scaffold doubled cell number and increased matrix production for all architectures studied. However, scaffold architecture dictated the type of matrix produced by cells, regardless of fibrin addition. Axial scaffolds, mimicking native tendon, promoted a mature matrix, with increased tenomodulin, a marker for mature tendon cells, and decreased scleraxis, an early transcription factor for connective tissue. This study demonstrated that both architectural cues and fibrin gel addition alter cell behavior and that the combination of these signals could improve clinical performance of current tissue engineering constructs.

  8. Varying whole body vibration amplitude differentially affects tendon and ligament structural and material properties

    PubMed Central

    Keller, Benjamin V.; Davis, Matthew L.; Thompson, William R.; Dahners, Laurence E.; Weinhold, Paul S.

    2014-01-01

    Whole Body Vibration (WBV) is becoming increasingly popular for helping to maintain bone mass and strengthening muscle. Vibration regimens optimized for bone maintenance often operate at hypogravity levels (<1 G) and regimens for muscle strengthening often employ hypergravity (>1 G) vibrations. The effect of vibratory loads on tendon and ligament properties is unclear though excessive vibrations may be injurious. Our objective was to evaluate how tendon gene expression and the mechanical/histological properties of tendon and ligament were affected in response to WBV in the following groups: no vibration, low vibration (0.3 G peak-to-peak), and high vibration (2 G peak-to-peak). Rats were vibrated for 20 min a day, 5 days a week, for 5 weeks. Upon sacrifice, the medial collateral ligament (MCL), patellar tendon (PT), and the Achilles Tendon (AT) were isolated with insertion sites intact. All tissues were tensile tested to determine structural and material properties or used for histology. Patellar tendon was also subjected to quantitative RT-PCR to evaluate expression of anabolic and catabolic genes. No differences in biomechanical data between the control and the low vibration groups were found. There was evidence of significant weakness in the MCL with high vibration, but no significant effect on the PT or AT. Histology of the MCL and PT showed a hypercellular tissue response and some fiber disorganization with high vibration. High vibration caused an increase in collagen expression and a trend for an increase in IGF-1 expression suggesting a potential anabolic response to prevent tendon overuse injury. PMID:23623311

  9. Dissection of a single rat muscle-tendon complex changes joint moments exerted by neighboring muscles: implications for invasive surgical interventions.

    PubMed

    Maas, Huub; Baan, Guus C; Huijing, Peter A

    2013-01-01

    The aim of this paper is to investigate mechanical functioning of a single skeletal muscle, active within a group of (previously) synergistic muscles. For this purpose, we assessed wrist angle-active moment characteristics exerted by a group of wrist flexion muscles in the rat for three conditions: (i) after resection of the upper arm skin; (ii) after subsequent distal tenotomy of flexor carpi ulnaris muscle (FCU); and (iii) after subsequent freeing of FCU distal tendon and muscle belly from surrounding tissues (MT dissection). Measurements were performed for a control group and for an experimental group after recovery (5 weeks) from tendon transfer of FCU to extensor carpi radialis (ECR) insertion. To assess if FCU tenotomy and MT dissection affects FCU contributions to wrist moments exclusively or also those of neighboring wrist flexion muscles, these data were compared to wrist angle-moment characteristics of selectively activated FCU. FCU tenotomy and MT dissection decreased wrist moments of the control group at all wrist angles tested, including also angles for which no or minimal wrist moments were measured when activating FCU exclusively. For the tendon transfer group, wrist flexion moment increased after FCU tenotomy, but to a greater extent than can be expected based on wrist extension moments exerted by selectively excited transferred FCU. We conclude that dissection of a single muscle in any surgical treatment does not only affect mechanical characteristics of the target muscle, but also those of other muscles within the same compartment. Our results demonstrate also that even after agonistic-to-antagonistic tendon transfer, mechanical interactions with previously synergistic muscles do remain present.

  10. Engineering cellular fibers for musculoskeletal soft tissues using directed self-assembly.

    PubMed

    Schiele, Nathan R; Koppes, Ryan A; Chrisey, Douglas B; Corr, David T

    2013-05-01

    Engineering strategies guided by developmental biology may enhance and accelerate in vitro tissue formation for tissue engineering and regenerative medicine applications. In this study, we looked toward embryonic tendon development as a model system to guide our soft tissue engineering approach. To direct cellular self-assembly, we utilized laser micromachined, differentially adherent growth channels lined with fibronectin. The micromachined growth channels directed human dermal fibroblast cells to form single cellular fibers, without the need for a provisional three-dimensional extracellular matrix or scaffold to establish a fiber structure. Therefore, the resulting tissue structure and mechanical characteristics were determined solely by the cells. Due to the self-assembly nature of this approach, the growing fibers exhibit some key aspects of embryonic tendon development, such as high cellularity, the rapid formation (within 24 h) of a highly organized and aligned cellular structure, and the expression of cadherin-11 (indicating direct cell-to-cell adhesions). To provide a dynamic mechanical environment, we have also developed and characterized a method to apply precise cyclic tensile strain to the cellular fibers as they develop. After an initial period of cellular fiber formation (24 h postseeding), cyclic strain was applied for 48 h, in 8-h intervals, with tensile strain increasing from 0.7% to 1.0%, and at a frequency of 0.5 Hz. Dynamic loading dramatically increased cellular fiber mechanical properties with a nearly twofold increase in both the linear region stiffness and maximum load at failure, thereby demonstrating a mechanism for enhancing cellular fiber formation and mechanical properties. Tissue engineering strategies, designed to capture key aspects of embryonic development, may provide unique insight into accelerated maturation of engineered replacement tissue, and offer significant advances for regenerative medicine applications in tendon, ligament, and other fibrous soft tissues.

  11. Histological study of the influence of plasma rich in growth factors (PRGF) on the healing of divided Achilles tendons in sheep.

    PubMed

    Fernández-Sarmiento, J Andrés; Domínguez, Juan M; Granados, María M; Morgaz, Juan; Navarrete, Rocío; Carrillo, José M; Gómez-Villamandos, Rafael J; Muñoz-Rascón, Pilar; Martín de Las Mulas, Juana; Millán, Yolanda; García-Balletbó, Montserrat; Cugat, Ramón

    2013-02-06

    The use of plasma rich in growth factors (PRGF) has been proposed to improve the healing of Achilles tendon injuries, but there is debate about the effectiveness of this therapy. The objective of the present study was to evaluate the histological effects of PRGF, which is a type of leukocyte-poor platelet-rich plasma, on tendon healing. The Achilles tendons of twenty-eight sheep were divided surgically. The animals were randomly divided into four groups of seven animals each. The repaired tendons in two groups received an infiltration of PRGF intraoperatively and every week for the following three weeks under ultrasound guidance. The tendons in the other two groups received injections with saline solution. The animals in one PRGF group and one saline solution group were killed at four weeks, and the animals in the remaining two groups were killed at eight weeks. The Achilles tendons were examined histologically, and the morphometry of fibroblast nuclei was calculated. The fibroblast nuclei of the PRGF-treated tendons were more elongated and more parallel to the tendon axis than the fibroblast nuclei of the tendons in the saline solution group at eight weeks. PRGF-treated tendons showed more packed and better oriented collagen bundles at both four and eight weeks. In addition to increased maturation of the collagen structure, fibroblast density was significantly lower in PRGF-infiltrated tendons. PRGF-treated tendons exhibited faster vascular regression than tendons in the control groups, as demonstrated by a lower vascular density at eight weeks. PRGF was associated with histological changes consistent with an accelerated early healing process in repaired Achilles tendons in sheep after experimental surgical disruption. PRGF-treated tendons showed improvements in the morphometric features of fibroblast nuclei, suggesting a more advanced stage of healing. At eight weeks, histological examination revealed more mature organization of collagen bundles, lower vascular densities, and decreased fibroblast densities in PRGF-treated tendons than in tendons infiltrated with saline solution. These findings were consistent with a more advanced stage of the healing process. Based on the findings in this animal model, PRGF infiltration may improve the early healing process of surgically repaired Achilles tendons.

  12. Reappraisal of the ligament of Henle (ligamentum inguinale internum mediale; Henle, 1871): a topohistological study using Korean foetuses.

    PubMed

    Yang, J D; Hwang, H P; Kim, J H; Murakami, G; Rodríguez-Vázquez, J F; Cho, B H

    2013-05-01

    Ligament of Henle is one of muscle-associated connective tissues of the rectus abdominis muscle, but it has been confused with the conjoint tendon (a common aponeurosis for insertion of the inferomedial end of the obliquus internus and transversus abdominis muscles). To reconsider the inguinal connective tissue structures, we examined 20 mid-term foetuses (10 males and 10 females) at approximately 14-20 weeks of gestation (crown rump length 100-170 mm). In female horizontal sections, we consistently found the ligament of Henle asa wing-like aponeurosis extending from the lateral margin of the rectus tendon behind the superficial inguinal ring. The ligament was separated from and located behind the conjoint tendon. In all male foetuses, instead of the ligament, the conjoint tendon was evident behind the superficial ring and it winded around the posterior aspect of the spermatic cord. Therefore, although a limited number of specimens were examined, the ligament of Henle was likely to be a female-specific structure. The ligament of Henle, if developed well, may provide an arch-like structure suitable for a name "falx inguinalis" instead of the inferomedial end ofthe conjoint tendon. In addition, a covering fascia of the iliopsoas muscle joined the posterior wall of the inguinal canal in male, but not in female, specimens.

  13. Dual growth factor-immobilized asymmetrically porous membrane for bone-to-tendon interface regeneration on rat patellar tendon avulsion model.

    PubMed

    Kim, Joong-Hyun; Oh, Se Heang; Min, Hyun Ki; Lee, Jin Ho

    2018-01-01

    Insufficient repair of the bone-to-tendon interface (BTI) with structural/compositional gradients has been a significant challenge in orthopedics. In this study, dual growth factor (platelet-derived growth factor-BB [PDGF-BB] and bone morphogenetic protein-2 [BMP-2])-immobilized polycaprolactone (PCL)/Pluronic F127 asymmetrically porous membrane was fabricated to estimate its feasibility as a potential strategy for effective regeneration of BTI injury. The growth factors immobilized (via heparin-intermediated interactions) on the membrane were continuously released for up to ∼80% of the initial loading amount after 5 weeks without a significant initial burst. From the in vivo animal study using a rat patellar tendon avulsion model, it was observed that the PDGF-BB/BMP-2-immobilized membrane accelerates the regeneration of the BTI injury, probably because of the continuous release of both growth factors (biological stimuli) and their complementary effect to create a multiphasic structure (bone, fibrocartilage, and tendon) like a native structure, as well as the role of the asymmetrically porous membrane as a physical barrier (nanopore side; prevention of fibrous tissue invasion into the defect site) and scaffold (micropore side; guidance for tissue regeneration). © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 115-125, 2018. © 2017 Wiley Periodicals, Inc.

  14. Corrosion of post-tensioned tendons with deficient grout : [summary].

    DOT National Transportation Integrated Search

    2016-10-01

    Stressed steel cables greatly increase the strength and capability of concrete structural : components, providing tensile strength that concrete alone does not possess. The cables : called tendons run through sealed tubes in the concrete whic...

  15. Biomechanical characteristics of the horizontal mattress stitch: implication for double-row and suture-bridge rotator cuff repair.

    PubMed

    Tamboli, Mallika; Mihata, Teruhisa; Hwang, James; McGarry, Michelle H; Kang, Yangmi; Lee, Thay Q

    2014-03-01

    We investigated the effects of bite-size horizontal mattress stitch (distance between the limbs passed through the tendon) on the biomechanical properties of the repaired tendon. We anchored 20 bovine Achilles tendons to bone using no. 2 high-strength suture and 5-mm titanium suture anchors in a mattress-suture technique. Tendons were allocated randomly into two groups of ten each to receive stitches with a 4- or 10-mm bite. Specimens underwent cyclic loading from 5 to 30 N at 1 mm/s for 30 cycles, followed by tensile testing to failure. Gap formation, tendon strain, hysteresis, stiffness, yield load, ultimate load, energy to yield load, and energy to ultimate load were compared between groups using unpaired t tests. The 4-mm group had less (p < 0.05) gap formation and less (p < 0.05) longitudinal strain than did the 10-mm group. Ultimate load (293.6 vs. 148.9 N) and energy to ultimate load (2,563 vs. 1,472 N-mm) were greater (p < 0.001) for the 10-mm group than the 4-mm group. All tendons repaired with 4-mm suturing failed at the suture-tendon interface, with sutures pulling through the tendon, whereas the suture itself failed before the tendon did in seven of the ten specimens in the 10-mm group. Whereas a 4-mm bite fixed the tendon more tightly but at the cost of decreased ultimate strength, a 10-mm bite conveyed greater ultimate strength but with increased gap and strain. These results suggest that for the conventional double-row repair, small mattress stitches provide a tighter repair, whereas large stitches are beneficial to prevent sutures from pulling through the tendon after surgery. For suture-bridge rotator cuff repair, large stitches are beneficial because the repaired tendon has a higher strength, and the slightly mobile medial knot can be tightened by lateral fixation.

  16. Do Magnetic Resonance Imaging Characteristics of Full-Thickness Rotator Cuff Tears Correlate With Sleep Disturbance?

    PubMed

    Reyes, Bryan A; Hull, Brandon R; Kurth, Alexander B; Kukowski, Nathan R; Mulligan, Edward P; Khazzam, Michael S

    2017-11-01

    Many patients with rotator cuff tears suffer from nocturnal shoulder pain, resulting in sleep disturbance. To determine whether rotator cuff tear size correlated with sleep disturbance in patients with full-thickness rotator cuff tears. Cross-sectional study; Level of evidence, 3. Patients with a diagnosis of unilateral full-thickness rotator cuff tears (diagnosed via magnetic resonance imaging [MRI]) completed the Pittsburgh Sleep Quality Index (PSQI), a visual analog scale (VAS) quantifying their shoulder pain, and the American Shoulder and Elbow Surgeons (ASES) questionnaire. Shoulder MRI scans were analyzed for anterior-posterior tear size (mm), tendon retraction (mm), Goutallier grade (0-4), number of tendons involved (1-4), muscle atrophy (none, mild, moderate, or severe), and humeral head rise (present or absent). Bivariate correlations were calculated between the MRI characteristics and baseline survey results. A total of 209 patients with unilateral full-thickness rotator cuff tears were included in this study: 112 (54%) female and 97 (46%) male (mean age, 64.1 years). On average, shoulder pain had been present for 24 months. The mean PSQI score was 9.8, and the mean VAS score was 5.0. No significant correlations were found between any of the rotator cuff tear characteristics and sleep quality. Only tendon retraction had a significant correlation with pain. Although rotator cuff tears are frequently associated with nocturnal pain and sleep disruption, this study demonstrated that morphological characteristics of full-thickness rotator cuff tears, such as size and tendon retraction, do not correlate with sleep disturbance and have little to no correlation with pain levels.

  17. [Flexor tendon repair: a short story].

    PubMed

    Moutet, F; Corcella, D; Forli, A; Mesquida, V

    2014-12-01

    This short story of flexor tendon repair aims to illustrate hesitations and wanderings of this surgery. Obviously tendon repair was very early considered, but it developed and diffused rather lately. It became a routine practice only in 20th century. This was due on the one hand, in Occident, to the Galen's dogmatic interdiction, on the other hand, to the repair difficulties of this paradoxical structure. Actually tendon is made of fibroblasts and collagen (sticky substances), and then its only goal is to move. According to this necessity, whatever the used techniques are, gliding is the final purpose. Technical evolutions are illustrated by historical contributions to flexor tendon surgery of several "giants" of hand surgery. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  18. Isolation and biological characterization of tendon-derived stem cells from fetal bovine.

    PubMed

    Yang, Jinjuan; Zhao, Qianjun; Wang, Kunfu; Liu, Hao; Ma, Caiyun; Huang, Hongmei; Liu, Yingjie

    2016-09-01

    The lack of appropriate candidates of cell sources for cell transplantation has hampered efforts to develop therapies for tendon injuries, such as tendon rupture, tendonitis, and tendinopathy. Tendon-derived stem cells (TDSCs) are a type of stem cells which may be used in the treatment of tendon injuries. In this study, TDSCs were isolated from 5-mo-old Luxi Yellow fetal bovine and cultured in vitro and further analyzed for their biological characteristics using immunofluorescence and reverse transcription-polymerase chain reaction (RT-PCR) assays. It was found that primary TDSCs could be expanded for 42 passages in vitro maintaining proliferation. The expressions of stem cell marker nucleostemin and tenocyte-related markers, such as collagen I, collagen II, collagen III, and tenascin-C, were observed on different passage cells by immunofluorescence. The results from RT-PCR show that TDSCs were positive for collagen type I, CD44, tenascin-C, and collagen type III but negative for collagen type II. Meanwhile, TDSC passage 4 was successfully induced to differentiate into osteoblasts, adipocytes, and chondrocytes. Our results indicate that the fetal bovine TDSCs not only had strong self-renewal capacity but also possess the potential for multi-lineage differentiation. This study provides theoretical basis and experimental foundation for potential therapeutic application of the fetal bovine TDSCs in the treatment of tendon injuries.

  19. * Fabrication and Characterization of Biphasic Silk Fibroin Scaffolds for Tendon/Ligament-to-Bone Tissue Engineering.

    PubMed

    Font Tellado, Sònia; Bonani, Walter; Balmayor, Elizabeth R; Foehr, Peter; Motta, Antonella; Migliaresi, Claudio; van Griensven, Martijn

    2017-08-01

    Tissue engineering is an attractive strategy for tendon/ligament-to-bone interface repair. The structure and extracellular matrix composition of the interface are complex and allow for a gradual mechanical stress transfer between tendons/ligaments and bone. Thus, scaffolds mimicking the structural features of the native interface may be able to better support functional tissue regeneration. In this study, we fabricated biphasic silk fibroin scaffolds designed to mimic the gradient in collagen molecule alignment present at the interface. The scaffolds had two different pore alignments: anisotropic at the tendon/ligament side and isotropic at the bone side. Total porosity ranged from 50% to 80% and the majority of pores (80-90%) were <100-300 μm. Young's modulus varied from 689 to 1322 kPa depending on the type of construct. In addition, human adipose-derived mesenchymal stem cells were cultured on the scaffolds to evaluate the effect of pore morphology on cell proliferation and gene expression. Biphasic scaffolds supported cell attachment and influenced cytoskeleton organization depending on pore alignment. In addition, the gene expression of tendon/ligament, enthesis, and cartilage markers significantly changed depending on pore alignment in each region of the scaffolds. In conclusion, the biphasic scaffolds fabricated in this study show promising features for tendon/ligament-to-bone tissue engineering.

  20. Biochemical and Anatomical Characteristics of Dolphin Muscles.

    DTIC Science & Technology

    1984-01-01

    the Bioengineering Branch (Code 5143) of the Naval Ocean Systems Center and the Kinesiology Department of the University of California, Los Angeles...such a sample. TENDON ANALYSES The biochemistry of the dolphin tendon suggests that this tissue is well adapted to withstand large forces and significant...neuromuscular physiology, connective tissue, and muscle biochemistry . A detailed proposal outlining the goals, approach, milestones, and costs for

  1. Augmentation of Rotator Cuff Repair With Soft Tissue Scaffolds

    PubMed Central

    Thangarajah, Tanujan; Pendegrass, Catherine J.; Shahbazi, Shirin; Lambert, Simon; Alexander, Susan; Blunn, Gordon W.

    2015-01-01

    Background Tears of the rotator cuff are one of the most common tendon disorders. Treatment often includes surgical repair, but the rate of failure to gain or maintain healing has been reported to be as high as 94%. This has been substantially attributed to the inadequate capacity of tendon to heal once damaged, particularly to bone at the enthesis. A number of strategies have been developed to improve tendon-bone healing, tendon-tendon healing, and tendon regeneration. Scaffolds have received considerable attention for replacement, reconstruction, or reinforcement of tendon defects but may not possess situation-specific or durable mechanical and biological characteristics. Purpose To provide an overview of the biology of tendon-bone healing and the current scaffolds used to augment rotator cuff repairs. Study Design Systematic review; Level of evidence, 4. Methods A preliminary literature search of MEDLINE and Embase databases was performed using the terms rotator cuff scaffolds, rotator cuff augmentation, allografts for rotator cuff repair, xenografts for rotator cuff repair, and synthetic grafts for rotator cuff repair. Results The search identified 438 unique articles. Of these, 214 articles were irrelevant to the topic and were therefore excluded. This left a total of 224 studies that were suitable for analysis. Conclusion A number of novel biomaterials have been developed into biologically and mechanically favorable scaffolds. Few clinical trials have examined their effect on tendon-bone healing in well-designed, long-term follow-up studies with appropriate control groups. While there is still considerable work to be done before scaffolds are introduced into routine clinical practice, there does appear to be a clear indication for their use as an interpositional graft for large and massive retracted rotator cuff tears and when repairing a poor-quality degenerative tendon. PMID:26665095

  2. Differences in glutamate receptors and inflammatory cell numbers are associated with the resolution of pain in human rotator cuff tendinopathy.

    PubMed

    Dean, Benjamin John Floyd; Snelling, Sarah J B; Dakin, Stephanie G; Murphy, Richard J; Javaid, Muhammad Kassim; Carr, Andrew Jonathan

    2015-07-10

    The relationship between peripheral tissue characteristics and pain symptoms in soft tissue inflammation is poorly understood. The primary aim of this study was to determine immunohistochemical differences in tissue obtained from patients with persistent pain and patients who had become pain-free after surgical treatment for rotator cuff tendinopathy. The secondary aim was to investigate whether there would be differences in glutaminergic and inflammatory gene expression between disease-derived and healthy control cells in vitro. Supraspinatus tendon biopsies were obtained from nine patients with tendon pain before shoulder surgery and from nine further patients whose pain had resolved completely following shoulder surgery. Histological markers relating to the basic tendon characteristics, inflammation and glutaminergic signalling were quantified by immunohistochemical analysis. Gene expression of glutaminergic and inflammatory markers was determined in tenocyte explants derived from painful rotator cuff tendon tears in a separate cohort of patients and compared to that of explants from healthy control tendons. Dual labelling was performed to identify cell types expressing nociceptive neuromodulators. Tendon samples from patients with persistent pain demonstrated increased levels of metabotropic glutamate receptor 2 (mGluR2), kainate receptor 1 (KA1), protein gene product 9.5 (PGP9.5), CD206 (macrophage marker) and CD45 (pan-leucocyte marker) versus pain-free controls (p <0.05). NMDAR1 co-localised with CD206-positive cells, whereas PGP9.5 and glutamate were predominantly expressed by resident tendon cells. These results were validated by in vitro increases in the expression of mGluR2, N-methyl-D-aspartate receptor (NMDAR1), KA1, CD45, CD206 and tumour necrosis factor alpha (TNF-α) genes (p <0.05) in disease-derived versus control cells. We conclude that differences in glutamate receptors and inflammatory cell numbers are associated with the resolution of shoulder pain in rotator cuff tendinopathy, and that disease-derived cells exhibit a distinctly different neuro-inflammatory gene expression profile to healthy control cells.

  3. Biomechanical and structural parameters of tendons in rats subjected to swimming exercise.

    PubMed

    Bezerra, M A; Santos de Lira, K D; Coutinho, M P G; de Mesquita, G N; Novaes, K A; da Silva, R T B; de Brito Nascimento, A K; Inácio Teixeira, M F H B; Moraes, S R A

    2013-12-01

    The aim of this study was to evaluate the effect of swimming exercise, without overloading, on the biomechanical parameters of the calcaneal tendon of rats. 27 male Wistar rats (70 days) were distributed randomly into 2 groups, Control Group (CG; n=15) with restricted movements inside the cage and Swimming Group (SG; n=12), subjected to exercise training in a tank with a water temperature of 30±1°C, for 1 h/day, 5 days/week for 8 weeks. All animals were kept in a reversed light/dark cycle of 12 h with access to food and water ad libitum. After that, they were anesthetized and had their calcaneus tendons collected from their left rear paws. The tendon was submitted to a mechanical test on a conventional test machine. From the stress vs. strain curve, the biomechanical data were analyzed. For the statistical analysis, the Student-T test was used (p<0.05). Of the variables examined, the maximum tension (p=0.009), maximum force (p=0.03), energy of deformation/tendon cross sectional area (p=0.017) and elastic modulus of the tendon (p=0.013) showed positive outcomes in SG. There was no difference in the other parameters. The results indicate that the swimming exercise training, without overloading, was an important stimulus for improving the biomechanical parameters and structural properties of the calcaneal tendon. © Georg Thieme Verlag KG Stuttgart · New York.

  4. Effects of plyometric and isometric training on muscle and tendon stiffness in vivo.

    PubMed

    Kubo, Keitaro; Ishigaki, Tomonobu; Ikebukuro, Toshihiro

    2017-08-01

    The purpose of this study was to compare the effects of plyometric and isometric training on tendon properties during ramp and ballistic contractions and muscle stiffness under passive and active conditions. Eleven subjects completed 12 weeks (3 days/week) of a unilateral training program for the plantar flexors. They performed plyometric training on one side (PLY) and isometric training on the other side (ISO). Active muscle stiffness in the medial gastrocnemius muscle was calculated according to changes in estimated muscle force and fascicle length during fast stretching after submaximal isometric contractions. Passive muscle stiffness was also calculated from estimated passive muscle force and fascicle length during slow passive stretching. Stiffness and hysteresis of tendon structures were measured using ultrasonography during ramp and ballistic contractions. Passive muscle stiffness and tendon hysteresis did not change for PLY or ISO Active muscle stiffness significantly increased for PLY, but not for ISO Tendon stiffness during ramp and ballistic contractions increased significantly for ISO, but not for PLY In addition, tendon elongation values at force production levels beyond 100 N during ballistic contractions increased for PLY These results suggest that plyometric training (but not isometric training) enhances the extensibility of tendon structures during ballistic contractions and active muscle stiffness during fast stretching, and these changes may be related to improved performances during stretch-shortening cycle exercises. © 2017 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.

  5. Lower Robotic Arm Assembly Having a Plurality of Tendon Driven Digits

    NASA Technical Reports Server (NTRS)

    Bridgwater, Lyndon (Inventor); Nguyen, Vienny (Inventor); Radford, Nicolaus A. (Inventor); Guo, Raymond (Inventor)

    2016-01-01

    A lower robotic arm includes a base structure, a plurality of digits, and a plurality of tendons. The digits each include first, second, third, and fourth phalanges. Each digit is operatively attached to the base structure at the respective first phalange. A first joint operatively connects the first and second phalange to define a first axis, a second operatively connects the second and third phalange to define a second axis, and a third joint operatively connects the third and fourth phalange to define a third axis, such that the phalanges are selectively rotatable relative to the adjacent phalange, about the respective axis. The tendons are operatively connected to a respective one of the fourth phalanges. Each tendon selectively applies a first torque to the respective fourth phalange to urge the respective phalanges to rotate in a first direction about the respective axes.

  6. Epigenetic regulation of metalloproteinases and their inhibitors in rotator cuff tears

    PubMed Central

    Caires dos Santos, Leonardo; Martins de Oliveira, Adrielle; Santoro Belangero, Paulo; Antônio Figueiredo, Eduardo; Cohen, Carina; de Seixas Alves, Felipe; Hiromi Yanaguizawa, Wânia; Vicente Andreoli, Carlos; de Castro Pochini, Alberto; Ejnisman, Benno; Cardoso Smith, Marília; de Seixas Alves, Maria Teresa; Cohen, Moises

    2017-01-01

    Rotator cuff tear is a common orthopedic condition. Metalloproteinases (MMP) and their inhibitors (TIMP) seem to play a role in the development of joint injuries and in the failure of tissue healing. However, the mechanisms of regulation of gene expression in tendons are still unknown. Epigenetic mechanisms, such as DNA methylation and microRNAs regulation, are involved in the dynamic control of gene expression. Here, the mRNA expression and DNA methylation status of MMPs (MMP1, MMP2, MMP3, MMP9, MMP13, and MMP14) and TIMPs (TIMP1-3) and the expression of miR-29 family members in ruptured supraspinatus tendons were compared with non-injured tendons of individuals without this lesion. Additionally, the gene expression and methylation status at the edge of the ruptured tendon were compared with macroscopically non-injured rotator cuff tendon samples from the anterior and posterior regions of patients with tendon tears. Moreover, the possible associations between the molecular alterations and the clinical and histologic characteristics were investigated. Dysregulated expression and DNA methylation of MMP and TIMP genes were found across the rotator cuff tendon samples of patients with supraspinatus tears. These alterations were influenced at least in part by age at surgery, sex, smoking habit, tear size, and duration of symptoms. Alterations in the studied MMP and TIMP genes may contribute to the presence of microcysts, fissures, necrosis, and neovascularization in tendons and may thus be involved in the tendon healing process. In conclusion, MMPs and their inhibitors are regulated by epigenetic modifications and may play a role in rotator cuff tears. PMID:28902861

  7. Ultrasound elasticity imaging of human posterior tibial tendon

    NASA Astrophysics Data System (ADS)

    Gao, Liang

    Posterior tibial tendon dysfunction (PTTD) is a common degenerative condition leading to a severe impairment of gait. There is currently no effective method to determine whether a patient with advanced PTTD would benefit from several months of bracing and physical therapy or ultimately require surgery. Tendon degeneration is closely associated with irreversible degradation of its collagen structure, leading to changes to its mechanical properties. If these properties could be monitored in vivo, it could be used to quantify the severity of tendonosis and help determine the appropriate treatment. Ultrasound elasticity imaging (UEI) is a real-time, noninvasive technique to objectively measure mechanical properties in soft tissue. It consists of acquiring a sequence of ultrasound frames and applying speckle tracking to estimate displacement and strain at each pixel. The goals of my dissertation were to 1) use acoustic simulations to investigate the performance of UEI during tendon deformation with different geometries; 2) develop and validate UEI as a potentially noninvasive technique for quantifying tendon mechanical properties in human cadaver experiments; 3) design a platform for UEI to measure mechanical properties of the PTT in vivo and determine whether there are detectable and quantifiable differences between healthy and diseased tendons. First, ultrasound simulations of tendon deformation were performed using an acoustic modeling program. The effects of different tendon geometries (cylinder and curved cylinder) on the performance of UEI were investigated. Modeling results indicated that UEI accurately estimated the strain in the cylinder geometry, but underestimated in the curved cylinder. The simulation also predicted that the out-of-the-plane motion of the PTT would cause a non-uniform strain pattern within incompressible homogeneous isotropic material. However, to average within a small region of interest determined by principal component analysis (PCA) would improve the estimation. Next, UEI was performed on five human cadaver feet mounted in a materials testing system (MTS) while the PTT was attached to a force actuator. A portable ultrasound scanner collected 2D data during loading cycles. Young's modulus was calculated from the strain, loading force and cross sectional area of the PTT. Average Young's modulus for the five tendons was (0.45+/-0.16GPa) using UEI. This was consistent with simultaneous measurements made by the MTS across the whole tendon (0.52+/-0.18GPa). We also calculated the scaling factor (0.12+/-0.01) between the load on the PTT and the inversion force at the forefoot, a measurable quantity in vivo. This study suggests that UEI could be a reliable in vivo technique for estimating the mechanical properties of the human PTT. Finally, we built a custom ankle inversion platform for in vivo imaging of human subjects (eight healthy volunteers and nine advanced PTTD patients). We found non-linear elastic properties of the PTTD, which could be quantified by the slope between the elastic modulus (E) and the inversion force (F). This slope (DeltaE/DeltaF), or Non-linear Elasticity Parameter (NEP), was significantly different for the two groups: 0.16+/-0.20 MPa/N for healthy tendons and 0.45+/-0.43 MPa/N for PTTD tendons. A receiver operating characteristic (ROC) curve revealed an area under the curve (AUC) of 0.83+/-0.07, which indicated that the classifier system is valid. In summary, the acoustic modeling, cadaveric studies, and in vivo experiments together demonstrated that UEI accurately quantifies tendon mechanical properties. As a valuable clinical tool, UEI also has the potential to help guide treatment decisions for advanced PTTD and other tendinopathies.

  8. The Location-Specific Role of Proteoglycans in the Flexor Carpi Ulnaris Tendon

    PubMed Central

    Buckley, Mark R.; Huffman, George R.; Iozzo, Renato V.; Birk, David E.; Soslowsky, Louis J.

    2015-01-01

    Tendons like the flexor carpi ulnaris (FCU) that contain region-specific distributions of proteoglycans (PGs) as a result of the heterogeneous, multi-axial loads they are subjected to in vivo provide valuable models for understanding structure-function relationships in connective tissues. However, the contributions of specific PGs to FCU tendon mechanical properties are unknown. Therefore, the objective of this study was to determine how the location-dependent, viscoelastic mechanical properties of the FCU tendon are impacted individually by PG-associated glycosaminoglycans (GAGs) and by two small leucine-rich proteoglycans (SLRPs), biglycan and decorin. Full length FCU tendons from biglycan- and decorin-null mice were compared to wild type mice to evaluate the effects of specific SLRPs, while chondroitinase ABC digestion of isolated specimens removed from the tendon midsubstance was used to determine how chontroitin/dermatan sulfate (CS/DS) GAGs impact mechanics in mature FCU tendons. A novel combined genetic knockout/ digestion technique also was employed to compare SLRP-null and wild-type tendons in the absence of CS/DS GAGs that may impact properties in the mature state. In all genotypes, mechanical properties in the FCU tendon midsubstance were not affected by GAG digestion. Full-length tendons exhibited complex, multi-axial deformation under tension that may be associated with their in vivo loading environment. Mechanical properties were adversely affected by the absence of biglycan, and a decreased modulus localized in the center of the tendon was measured. These results help elucidate the role that local alterations in proteoglycan levels may play in processes that adversely impact tendon functionality including injury and pathology. PMID:23941206

  9. Enhancing the Biomechanical Performance of Anisotropic Nanofibrous Scaffolds in Tendon Tissue Engineering: Reinforcement with Cellulose Nanocrystals.

    PubMed

    Domingues, Rui M A; Chiera, Silvia; Gershovich, Pavel; Motta, Antonella; Reis, Rui L; Gomes, Manuela E

    2016-06-01

    Anisotropically aligned electrospun nanofibrous scaffolds based on natural/synthetic polymer blends have been established as a reasonable compromise between biological and biomechanical performance for tendon tissue engineering (TE) strategies. However, the limited tensile properties of these biomaterials restrict their application in this field due to the load-bearing nature of tendon/ligament tissues. Herein, the use of cellulose nanocrystals (CNCs) as reinforcing nanofillers in aligned electrospun scaffolds based on a natural/synthetic polymer blend matrix, poly-ε-caprolactone/chitosan (PCL/CHT) is reported. The incorporation of small amounts of CNCs (up to 3 wt%) into tendon mimetic nanofiber bundles has a remarkable biomaterial-toughing effect (85% ± 5%, p < 0.0002) and raises the scaffolds mechanical properties to tendon/ligament relevant range (σ = 39.3 ± 1.9 MPa and E = 540.5 ± 83.7 MPa, p < 0.0001). Aligned PCL/CHT/CNC nanocomposite fibrous scaffolds meet not only the mechanical requirements for tendon TE applications but also provide tendon mimetic extracellular matrix (ECM) topographic cues, a key feature for maintaining tendon cell's morphology and behavior. The strategy proposed here may be extended to other anisotropic aligned nanofibrous scaffolds based on natural/synthetic polymer blends and enable the full exploitation of the advantages provided by their tendon mimetic fibrous structures in tendon TE. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Ontogeny of the Alligator Cartilago Transiliens and Its Significance for Sauropsid Jaw Muscle Evolution

    PubMed Central

    Tsai, Henry P.; Holliday, Casey M.

    2011-01-01

    The cartilago transiliens is a fibrocartilaginous structure within the jaw muscles of crocodylians. The cartilago transiliens slides between the pterygoid buttress and coronoid region of the lower jaw and connects two muscles historically identified as m. pseudotemporalis superficialis and m. intramandibularis. However, the position of cartilago transiliens, and its anatomical similarities to tendon organs suggest the structure may be a sesamoid linking a single muscle. Incompressible sesamoids often form inside tendons that wrap around bone. However, such structures rarely ossify in reptiles and have thus far received scant attention. We tested the hypothesis that the cartilago transiliens is a sesamoid developed within in one muscle by investigating its structure in an ontogenetic series of Alligator mississippiensis using dissection, 3D imaging, and polarizing and standard light microscopy. In all animals studied, the cartilago transiliens receives collagen fibers and tendon insertions from its two main muscular attachments. However, whereas collagen fibers were continuous within the cartilaginous nodule of younger animals, such continuity decreased in older animals, where the fibrocartilaginous core grew to displace the fibrous region. Whereas several neighboring muscles attached to the fibrous capsule in older individuals, only two muscles had significant contributions to the structure in young animals. Our results indicate that the cartilago transiliens is likely a sesamoid formed within a single muscle (i.e., m. pseudotemporalis superficialis) as it wraps around the pterygoid buttress. This tendon organ is ubiquitous among fossil crocodyliforms indicating it is a relatively ancient, conserved structure associated with the development of the large pterygoid flanges in this clade. Finally, these findings indicate that similar tendon organs exist among potentially homologous muscle groups in birds and turtles, thus impacting inferences of jaw muscle homology and evolution in sauropsids in general. PMID:21949795

  11. Visualization of the extra-articular portion of the long head of the biceps tendon during intra-articular shoulder arthroscopy.

    PubMed

    Festa, Anthony; Allert, Jesse; Issa, Kimona; Tasto, James P; Myer, Jonathan J

    2014-11-01

    To quantify the amount of the extra-articular long head of the biceps tendon (LHBT) seen during intra-articular shoulder arthroscopy by pulling the tendon into the joint with a probe through an anterior portal while viewing through a standard posterior portal. Intra-articular shoulder arthroscopy was performed on 10 forequarter cadaveric specimens. The extra-articular portion of the LHBT was evaluated by pulling the tendon into the joint with an arthroscopic probe inserted through an anterior portal. The tendon was marked at the pulley insertion on the humerus with a vascular clip before and after the tendon was pulled into the joint. An open deltopectoral approach was performed, and the amount of extra-articular tendon visualized was calculated as an absolute amount and in relation to nearby anatomic structures. An additional 1.9 cm (range, 1.4 to 2.6 cm) of extra-articular LHBT was viewed by pulling the tendon into the joint with an arthroscopic probe through an anterior portal during shoulder arthroscopy. This represented 30.8% of the extra-articular portion of the tendon, 47.7% of tendon in the bicipital groove, and 76.3% of the tendon that lies under the area from the pulley insertion to the distal edge of the transverse humeral ligament. During intra-articular shoulder arthroscopy, the extra-articular portion of the LHBT is incompletely visualized by pulling the tendon into the joint with a probe placed through an anterior portal while viewing through a standard posterior portal. An additional extra-articular portion of the LHBT may be viewed by pulling the tendon into the joint with an arthroscopic probe during shoulder arthroscopy. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  12. Comparison of Clinical and Structural Outcomes by Subscapularis Tendon Status in Massive Rotator Cuff Tear.

    PubMed

    Lee, Sung Hyun; Nam, Dae Jin; Kim, Se Jin; Kim, Jeong Woo

    2017-09-01

    The subscapularis tendon is essential in maintaining normal glenohumeral biomechanics. However, few studies have addressed the outcomes of tears extending to the subscapularis tendon in massive rotator cuff tears. To assess the clinical and structural outcomes of arthroscopic repair of massive rotator cuff tears involving the subscapularis. Cohort study; Level of evidence, 3. Between January 2010 and January 2014, 122 consecutive patients with massive rotator cuff tear underwent arthroscopic rotator cuff repair. Overall, 122 patients were enrolled (mean age, 66 years; mean follow-up period, 39.5 months). Patients were categorized into 3 groups based on subscapularis tendon status: intact subscapularis tendon (I group; n = 45), tear involving less than the superior one-third (P group; n = 35), and tear involving more than one-third of the subscapularis tendon (C group; n = 42). All rotator cuff tears were repaired; however, subscapularis tendon tears involving less than the superior one-third in P group were only debrided. Pain visual analog scale, Constant, and American Shoulder and Elbow Surgeons scores and passive range of motion were measured preoperatively and at the final follow-up. Rotator cuff integrity, global fatty degeneration index, and occupation ratio were determined via magnetic resonance imaging preoperatively and 6 months postoperatively. We identified 37 retears (31.1%) based on postoperative magnetic resonance imaging evaluation. Retear rate in patients in the C group (47.6%) was higher than that in the I group (22.9%) or P group (20.0%) ( P = .011). Retear subclassification based on the involved tendons showed that subsequent subscapularis tendon retears were noted in only the C group. The improvement in clinical scores after repair was statistically significant in all groups but not different among the groups. Between-group comparison showed significant differences in preoperative external rotation ( P = .021). However, no statistically significant difference was found in any shoulder range of motion measurements after surgery. Arthroscopic repair of massive tears results in substantial improvements in shoulder function, despite the presence of combined subscapularis tears. However, this study showed a high failure rate of massive posterosuperior rotator cuff tear repair extending more than one-third of the subscapularis tendon. When combined subscapularis tendon tear was less than the superior one-third of the subscapularis tendon, arthroscopic debridement was a reasonable treatment method where comparable clinical and anatomic outcomes could be expected.

  13. DNA fragmentation and nuclear phenotype in tendons exposed to low-intensity infrared laser

    NASA Astrophysics Data System (ADS)

    de Paoli, Flavia; Ramos Cerqueira, Larissa; Martins Ramos, Mayara; Campos, Vera M.; Ferreira-Machado, Samara C.; Geller, Mauro; de Souza da Fonseca, Adenilson

    2015-03-01

    Clinical protocols are recommended in device guidelines outlined for treating many diseases on empirical basis. However, effects of low-intensity infrared lasers at fluences used in clinical protocols on DNA are controversial. Excitation of endogenous chromophores in tissues and free radicals generation could be described as a consequence of laser used. DNA lesions induced by free radicals cause changes in DNA structure, chromatin organization, ploidy degrees and cell death. In this work, we investigated whether low-intensity infrared laser therapy could alter the fibroblasts nuclei characteristics and induce DNA fragmentation. Tendons of Wistar rats were exposed to low-intensity infrared laser (830 nm), at different fluences (1, 5 and 10 J/cm2), in continuous wave (power output of 10mW, power density of 79.6 mW/cm2). Different frequencies were analyzed for the higher fluence (10 J/cm2), at pulsed emission mode (2.5, 250 and 2500 Hz), with the laser source at surface of skin. Geometric, densitometric and textural parameters obtained for Feulgen-stained nuclei by image analysis were used to define nuclear phenotypes. Significant differences were observed on the nuclear phenotype of tendons after exposure to laser, as well as, high cell death percentages was observed for all fluences and frequencies analyzed here, exception 1 J/cm2 fluence. Our results indicate that low-intensity infrared laser can alter geometric, densitometric and textural parameters in tendon fibroblasts nuclei. Laser can also induce DNA fragmentation, chromatin lost and consequently cell death, using fluences, frequencies and emission modes took out from clinical protocols.

  14. Arthroscopic suture retrievers and shuttles: a biomechanical investigation of the force required for tendon penetration and defect size.

    PubMed

    Lenz, Christopher G; Wieser, Karl; Lajtai, Georg; Meyer, Dominik C

    2015-11-17

    To compare instruments designed for arthroscopic suture handling during arthroscopic rotator cuff repair, to assess the force needed to penetrate the tendon, and to evaluate the residual defect size. Twenty-one instruments were each tested ten times on thawed sheep infraspinatus tendons. The force needed to pierce the tendon with each instrument was measured using a custom setup. Bone wax plates were used to make the perforation marks visible and to quantify the lesions each instrument created. The force to pierce a tendon had a range of 5.6-18.5 N/mm. Within the group of suture retrievers, the angled instruments required in average 85 % higher forces than straight instruments. The lesion area had a range of 2-7 mm(2). Suture retrievers produced significantly larger lesion sizes compared with suture shuttles. For the identical task of passing a suture through a tendon, differences exist regarding the ease of tendon penetration and potential damage to the tendon for different tools. The design, function, and resulting lesion size may be relevant and important for surgical handling and to avoid excess structural damage to the tendon. These results suggest that choosing the most appropriate tools for arthroscopic suture stitching influences the ease of handling and final integrity of the tissue.

  15. Relationship between tendon stiffness and failure: a metaanalysis

    PubMed Central

    LaCroix, Andrew S.; Duenwald-Kuehl, Sarah E.; Lakes, Roderic S.

    2013-01-01

    Tendon is a highly specialized, hierarchical tissue designed to transfer forces from muscle to bone; complex viscoelastic and anisotropic behaviors have been extensively characterized for specific subsets of tendons. Reported mechanical data consistently show a pseudoelastic, stress-vs.-strain behavior with a linear slope after an initial toe region. Many studies report a linear, elastic modulus, or Young's modulus (hereafter called elastic modulus) and ultimate stress for their tendon specimens. Individually, these studies are unable to provide a broader, interstudy understanding of tendon mechanical behavior. Herein we present a metaanalysis of pooled mechanical data from a representative sample of tendons from different species. These data include healthy tendons and those altered by injury and healing, genetic modification, allograft preparation, mechanical environment, and age. Fifty studies were selected and analyzed. Despite a wide range of mechanical properties between and within species, elastic modulus and ultimate stress are highly correlated (R2 = 0.785), suggesting that tendon failure is highly strain-dependent. Furthermore, this relationship was observed to be predictable over controlled ranges of elastic moduli, as would be typical of any individual species. With the knowledge gained through this metaanalysis, noninvasive tools could measure elastic modulus in vivo and reasonably predict ultimate stress (or structural compromise) for diseased or injured tendon. PMID:23599401

  16. Viscoelastic shear lag model to predict the micromechanical behavior of tendon under dynamic tensile loading.

    PubMed

    Wu, Jiayu; Yuan, Hong; Li, Longyuan; Fan, Kunjie; Qian, Shanguang; Li, Bing

    2018-01-21

    Owing to its viscoelastic nature, tendon exhibits stress rate-dependent breaking and stiffness function. A Kelvin-Voigt viscoelastic shear lag model is proposed to illustrate the micromechanical behavior of the tendon under dynamic tensile conditions. Theoretical closed-form expressions are derived to predict the deformation and stress transfer between fibrils and interfibrillar matrix while tendon is dynamically stretched. The results from the analytical solutions demonstrate that how the fibril overlap length and fibril volume fraction affect the stress transfer and mechanical properties of tendon. We find that the viscoelastic property of interfibrillar matrix mainly results in collagen fibril failure under fast loading rate or creep rupture of tendon. However, discontinuous fibril model and hierarchical structure of tendon ensure relative sliding under slow loading rate, helping dissipate energy and protecting fibril from damage, which may be a key reason why regularly staggering alignment microstructure is widely selected in nature. According to the growth, injury, healing and healed process of tendon observed by many researchers, the conclusions presented in this paper agrees well with the experimental findings. Additionally, the emphasis of this paper is on micromechanical behavior of tendon, whereas this analytical viscoelastic shear lag model can be equally applicable to other soft or hard tissues, owning the similar microstructure. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Fibrin gels exhibit improved biological, structural, and mechanical properties compared with collagen gels in cell-based tendon tissue-engineered constructs.

    PubMed

    Breidenbach, Andrew P; Dyment, Nathaniel A; Lu, Yinhui; Rao, Marepalli; Shearn, Jason T; Rowe, David W; Kadler, Karl E; Butler, David L

    2015-02-01

    The prevalence of tendon and ligament injuries and inadequacies of current treatments is driving the need for alternative strategies such as tissue engineering. Fibrin and collagen biopolymers have been popular materials for creating tissue-engineered constructs (TECs), as they exhibit advantages of biocompatibility and flexibility in construct design. Unfortunately, a few studies have directly compared these materials for tendon and ligament applications. Therefore, this study aims at determining how collagen versus fibrin hydrogels affect the biological, structural, and mechanical properties of TECs during formation in vitro. Our findings show that tendon and ligament progenitor cells seeded in fibrin constructs exhibit improved tenogenic gene expression patterns compared with their collagen-based counterparts for approximately 14 days in culture. Fibrin-based constructs also exhibit improved cell-derived collagen alignment, increased linear modulus (2.2-fold greater) compared with collagen-based constructs. Cyclic tensile loading, which promotes the maturation of tendon constructs in a previous work, exhibits a material-dependent effect in this study. Fibrin constructs show trending reductions in mechanical, biological, and structural properties, whereas collagen constructs only show improved tenogenic expression in the presence of mechanical stimulation. These findings highlight that components of the mechanical stimulus (e.g., strain amplitude or time of initiation) need to be tailored to the material and cell type. Given the improvements in tenogenic expression, extracellular matrix organization, and material properties during static culture, in vitro findings presented here suggest that fibrin-based constructs may be a more suitable alternative to collagen-based constructs for tissue-engineered tendon/ligament repair.

  18. Fibrin Gels Exhibit Improved Biological, Structural, and Mechanical Properties Compared with Collagen Gels in Cell-Based Tendon Tissue-Engineered Constructs

    PubMed Central

    Dyment, Nathaniel A.; Lu, Yinhui; Rao, Marepalli; Shearn, Jason T.; Rowe, David W.; Kadler, Karl E.; Butler, David L.

    2015-01-01

    The prevalence of tendon and ligament injuries and inadequacies of current treatments is driving the need for alternative strategies such as tissue engineering. Fibrin and collagen biopolymers have been popular materials for creating tissue-engineered constructs (TECs), as they exhibit advantages of biocompatibility and flexibility in construct design. Unfortunately, a few studies have directly compared these materials for tendon and ligament applications. Therefore, this study aims at determining how collagen versus fibrin hydrogels affect the biological, structural, and mechanical properties of TECs during formation in vitro. Our findings show that tendon and ligament progenitor cells seeded in fibrin constructs exhibit improved tenogenic gene expression patterns compared with their collagen-based counterparts for approximately 14 days in culture. Fibrin-based constructs also exhibit improved cell-derived collagen alignment, increased linear modulus (2.2-fold greater) compared with collagen-based constructs. Cyclic tensile loading, which promotes the maturation of tendon constructs in a previous work, exhibits a material-dependent effect in this study. Fibrin constructs show trending reductions in mechanical, biological, and structural properties, whereas collagen constructs only show improved tenogenic expression in the presence of mechanical stimulation. These findings highlight that components of the mechanical stimulus (e.g., strain amplitude or time of initiation) need to be tailored to the material and cell type. Given the improvements in tenogenic expression, extracellular matrix organization, and material properties during static culture, in vitro findings presented here suggest that fibrin-based constructs may be a more suitable alternative to collagen-based constructs for tissue-engineered tendon/ligament repair. PMID:25266738

  19. Can chronic stretching change the muscle-tendon mechanical properties? A review.

    PubMed

    Freitas, S R; Mendes, B; Le Sant, G; Andrade, R J; Nordez, A; Milanovic, Z

    2018-03-01

    It is recognized that stretching is an effective method to chronically increase the joint range of motion. However, the effects of stretching training on the muscle-tendon structural properties remain unclear. This systematic review with meta-analysis aimed to determine whether chronic stretching alter the muscle-tendon structural properties. Published papers regarding longitudinal stretching (static, dynamic and/or PNF) intervention (either randomized or not) in humans of any age and health status, with more than 2 weeks in duration and at least 2 sessions per week, were searched in PubMed, PEDro, ScienceDirect and ResearchGate databases. Structural or mechanical variables from joint (maximal tolerated passive torque or resistance to stretch) or muscle-tendon unit (muscle architecture, stiffness, extensibility, shear modulus, volume, thickness, cross-sectional area, and slack length) were extracted from those papers. A total of 26 studies were selected, with a duration ranging from 3 to 8 weeks, and an average total time under stretching of 1165 seconds per week. Small effects were seen for maximal tolerated passive torque, but trivial effects were seen for joint resistance to stretch, muscle architecture, muscle stiffness, and tendon stiffness. A large heterogeneity was seen for most of the variables. Stretching interventions with 3- to 8-week duration do not seem to change either the muscle or the tendon properties, although it increases the extensibility and tolerance to a greater tensile force. Adaptations to chronic stretching protocols shorter than 8 weeks seem to mostly occur at a sensory level. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Morphology and Histology of Lower Limb Tendons and Ligaments in Primates.

    DTIC Science & Technology

    1981-08-01

    dlllerent from Report) IS. SUPPLEMENTARY NOTES 19. KEY WORDS (Continue on revermo sidIft neceses end Identify by block ntmbe) Tendon Plantar Osseo-fibrous...ligaments were sanded smooth to facilitate the utilization of mechanical testing grips. Dissection of the Foot: The plantar aspect of the foot was...removed to expose the inner structures. The tendo-calcaneus tendon was dissected first and was freed of fascia from the gastrocnemius muscle to the

  1. Traumatic Extensor Tendon Injuries to the Hand: Clinical Anatomy, Biomechanics, and Surgical Procedure Review.

    PubMed

    Colzani, Giulia; Tos, Pierluigi; Battiston, Bruno; Merolla, Giovanni; Porcellini, Giuseppe; Artiaco, Stefano

    2016-04-01

    The extensor apparatus is a complex muscle-tendon system that requires integrity or optimal reconstruction to preserve hand function. Anatomical knowledge and the understanding of physiopathology of extensor tendons are essential for an accurate diagnosis of extensor tendon injuries (ETIs) of the hand and wrist, because these lesions are complex and commonly observed in clinical practice. A careful clinical history and assessment still remain the first step for the diagnosis, followed by US and MR to confirm the suspect of ETI or to investigate some doubtful conditions and rule out associate lesions. During last decades the evolution of surgical techniques and rehabilitative treatment protocol led to gradual improvement in clinical results of ETI treatment and surgical repair. Injury classification into anatomical zones and the evaluation of the characteristics of the lesions are considered key points to select the appropriate treatment for ETI. Both conservative and surgical management can be indicated in ETI, depending on the anatomical zone and on the characteristics of the injuries. As a general rule, an attempt of conservative treatment should be performed when the lesion is expected to have favorable result with nonoperative procedure. Many surgical techniques have been proposed over the time and with favorable results if the tendon injury is not underestimated and adequately treated. Despite recent research findings, a lack of evidence-based knowledge is still observed in surgical treatment and postoperative management of ETI. Further clinical and biomechanical investigations would be advisable to clarify this complex issue.

  2. Traumatic Extensor Tendon Injuries to the Hand: Clinical Anatomy, Biomechanics, and Surgical Procedure Review

    PubMed Central

    Colzani, Giulia; Tos, Pierluigi; Battiston, Bruno; Merolla, Giovanni; Porcellini, Giuseppe; Artiaco, Stefano

    2016-01-01

    The extensor apparatus is a complex muscle-tendon system that requires integrity or optimal reconstruction to preserve hand function. Anatomical knowledge and the understanding of physiopathology of extensor tendons are essential for an accurate diagnosis of extensor tendon injuries (ETIs) of the hand and wrist, because these lesions are complex and commonly observed in clinical practice. A careful clinical history and assessment still remain the first step for the diagnosis, followed by US and MR to confirm the suspect of ETI or to investigate some doubtful conditions and rule out associate lesions. During last decades the evolution of surgical techniques and rehabilitative treatment protocol led to gradual improvement in clinical results of ETI treatment and surgical repair. Injury classification into anatomical zones and the evaluation of the characteristics of the lesions are considered key points to select the appropriate treatment for ETI. Both conservative and surgical management can be indicated in ETI, depending on the anatomical zone and on the characteristics of the injuries. As a general rule, an attempt of conservative treatment should be performed when the lesion is expected to have favorable result with nonoperative procedure. Many surgical techniques have been proposed over the time and with favorable results if the tendon injury is not underestimated and adequately treated. Despite recent research findings, a lack of evidence-based knowledge is still observed in surgical treatment and postoperative management of ETI. Further clinical and biomechanical investigations would be advisable to clarify this complex issue. PMID:27616821

  3. Heparin functionalization increases retention of TGF-β2 and GDF5 on biphasic silk fibroin scaffolds for tendon/ligament-to-bone tissue engineering.

    PubMed

    Font Tellado, Sònia; Chiera, Silvia; Bonani, Walter; Poh, Patrina S P; Migliaresi, Claudio; Motta, Antonella; Balmayor, Elizabeth R; van Griensven, Martijn

    2018-05-01

    The tendon/ligament-to-bone transition (enthesis) is a highly specialized interphase tissue with structural gradients of extracellular matrix composition, collagen molecule alignment and mineralization. These structural features are essential for enthesis function, but are often not regenerated after injury. Tissue engineering is a promising strategy for enthesis repair. Engineering of complex tissue interphases such as the enthesis is likely to require a combination of biophysical, biological and chemical cues to achieve functional tissue regeneration. In this study, we cultured human primary adipose-derived mesenchymal stem cells (AdMCs) on biphasic silk fibroin scaffolds with integrated anisotropic (tendon/ligament-like) and isotropic (bone/cartilage like) pore alignment. We functionalized those scaffolds with heparin and explored their ability to deliver transforming growth factor β2 (TGF-β2) and growth/differentiation factor 5 (GDF5). Heparin functionalization increased the amount of TGF-β2 and GDF5 remaining attached to the scaffold matrix and resulted in biological effects at low growth factor doses. We analyzed the combined impact of pore alignment and growth factors on AdMSCs. TGF-β2 and pore anisotropy synergistically increased the expression of tendon/ligament markers and collagen I protein content. In addition, the combined delivery of TGF-β2 and GDF5 enhanced the expression of cartilage markers and collagen II protein content on substrates with isotropic porosity, whereas enthesis markers were enhanced in areas of mixed anisotropic/isotropic porosity. Altogether, the data obtained in this study improves current understanding on the combined effects of biological and structural cues on stem cell fate and presents a promising strategy for tendon/ligament-to-bone regeneration. Regeneration of the tendon/ligament-to-bone interphase (enthesis) is of significance in the repair of ruptured tendons/ligaments to bone to improve implant integration and clinical outcome. This study proposes a novel approach for enthesis regeneration based on a biomimetic and integrated tendon/ligament-to-bone construct, stem cells and heparin-based delivery of growth factors. We show that heparin can keep growth factors local and biologically active at low doses, which is critical to avoid supraphysiological doses and associated side effects. In addition, we identify synergistic effects of biological (growth factors) and structural (pore alignment) cues on stem cells. These results improve current understanding on the combined impact of biological and structural cues on the multi-lineage differentiation capacity of stem cells for regenerating complex tissue interphases. Copyright © 2018 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  4. Assessment of Postoperative Tendon Quality in Patients With Achilles Tendon Rupture Using Diffusion Tensor Imaging and Tendon Fiber Tracking.

    PubMed

    Sarman, Hakan; Atmaca, Halil; Cakir, Ozgur; Muezzinoglu, Umit Sefa; Anik, Yonca; Memisoglu, Kaya; Baran, Tuncay; Isik, Cengiz

    2015-01-01

    Although pre- and postoperative imaging of Achilles tendon rupture (ATR) has been well documented, radiographic evaluations of postoperative intratendinous healing and microstructure are still lacking. Diffusion tensor imaging (DTI) is an innovative technique that offers a noninvasive method for describing the microstructure characteristics and organization of tissues. DTI was used in the present study for quantitative assessment of fiber continuity postoperatively in patients with acute ATR. The data from 16 patients with ATR from 2005 to 2012 were retrospectively analyzed. The microstructure of ART was evaluated using tendon fiber tracking, tendon continuity, fractional anisotropy, and apparent diffusion coefficient values by way of DTI. The distal and proximal portions were measured separately in both the ruptured and the healthy extremities of each patient. The mean patient age was 41.56 ± 8.49 (range 26 to 56) years. The median duration of follow-up was 21 (range 6 to 80) months. The tendon fractional anisotropy values of the ruptured Achilles tendon were significantly lower statistically than those of the normal side (p = .001). However, none of the differences between the 2 groups with respect to the distal and proximal apparent diffusion coefficient were statistically significant (p = .358 and p = .899, respectively). In addition, the fractional anisotropy and apparent diffusion coefficient measurements were not significantly different in the proximal and distal regions of the ruptured tendons compared with the healthy tendons. The present study used DTI and fiber tracking to demonstrate the radiologic properties of postoperative Achilles tendons with respect to trajectory and tendinous fiber continuity. Quantifying DTI and fiber tractography offers an innovative and effective tool that might be able to detect microstructural abnormalities not appreciable using conventional radiologic techniques. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Descriptive analysis of retirement of Thoroughbred racehorses due to tendon injuries at the Hong Kong Jockey Club (1992-2004).

    PubMed

    Lam, K H; Parkin, T D H; Riggs, C M; Morgan, K L

    2007-03-01

    This study was part of a programme to optimise the longevity and maximise the health and welfare of the Thoroughbred racehorses in Hong Kong. Injuries to the superficial digital flexor (SDF) tendon are the most common veterinary reason for premature retirement in this population. To describe the frequency and pattern of retirements associated with SDF tendon injuries in Thoroughbred racehorses and to compare the characteristics of these horses with those that retired for other reasons. A retrospective analysis of retirement records documented in the Hong Kong Jockey Club clinical database between 1992 and 2004 was conducted. As this is complete census data, no statistical inference to the population is necessary. The mean annual cumulative incidence of retirements due to tendon injury was 3.2% accounting for 14% of all retirements. The risk of tendon injury increased over the 12 year period from 23-4.2%. The racing career, number of starts and earnings of horses retired with tendon injuries were reduced by 25.6, 41.2 and 53.3%, respectively. Thirteen percent of these horses never raced in Hong Kong. A greater proportion of 3- and 4-year-olds and entire males were retired because of tendon injuries. Ninety-seven percent of injuries affected the forelimb, the right more frequently than the left. Only 19.7% of retired horses that had received ultrasound examination for SDF tendon injury retired for this reason. This study provides population based data on the frequency, career and economic losses associated with tendon injury induced retirement. This descriptive study has provided a useful resource for further case-control studies to investigate risk factors for retirement from racing due to tendon injury. This is the first step toward the development of management tools to reduce the incidence of tendon injury related retirement in Hong Kong.

  6. Arthroscopically Assisted Latissimus Dorsi Tendon Transfer in Beach-Chair Position

    PubMed Central

    Jermolajevas, Viktoras; Kordasiewicz, Bartlomiej

    2015-01-01

    Irreparable rotator cuff tears remain a surgical problem. The open technique of latissimus dorsi (LD) tendon transfer to “replace” the irreparable rotator cuff is already well known. The aim of this article is to present a modified arthroscopically assisted LD tendon transfer technique. This technique was adopted to operate on patients in the beach-chair position with several improvements in tendon harvesting and fixation. It can be divided into 6 steps, and only 1 step—LD muscle and tendon release—is performed open. The advantages of the arthroscopic procedure are sparing of the deltoid muscle, the possibility of repairing the subscapularis tendon, and the ability to visualize structures at risk while performing tendon harvesting (radial nerve) and passing into the subacromial space (axillary nerve). It is performed in a similar manner to standard rotator cuff surgery—the beach-chair position does not need any modification, and no sophisticated equipment for either the open or arthroscopic part of the procedure is necessary. Nevertheless, this is a challenging procedure and should only be attempted after training, as well as extensive practice. PMID:26759777

  7. Monitoring of Grouting Compactness in a Post-Tensioning Tendon Duct Using Piezoceramic Transducers

    PubMed Central

    Jiang, Tianyong; Kong, Qingzhao; Wang, Wenxi; Huo, Linsheng; Song, Gangbing

    2016-01-01

    A post-tensioning tendon duct filled with grout can effectively prevent corrosion of the reinforcement, maintain bonding behavior between the reinforcement and concrete, and enhance the load bearing capacity of concrete structures. In practice, grouting of the post-tensioning tendon ducts always causes quality problems, which may reduce structural integrity and service life, and even cause accidents. However, monitoring of the grouting compactness is still a challenge due to the invisibility of the grout in the duct during the grouting process. This paper presents a stress wave-based active sensing approach using piezoceramic transducers to monitor the grouting compactness in real time. A segment of a commercial tendon duct was used as research object in this study. One lead zirconate titanate (PZT) piezoceramic transducer with marble protection, called a smart aggregate (SA), was bonded on the tendon and installed in the tendon duct. Two PZT patch sensors were mounted on the top outside surface of the duct, and one PZT patch sensor was bonded on the bottom outside surface of the tendon duct. In the active sensing approach, the SA was used as an actuator to generate a stress wave and the PZT sensors were utilized to detect the wave response. Cement or grout in the duct functions as a wave conduit, which can propagate the stress wave. If the cement or grout is not fully filled in the tendon duct, the top PZT sensors cannot receive much stress wave energy. The experimental procedures simulated four stages during the grout pouring process, which includes empty status, half grouting, 90% grouting, and full grouting of the duct. Experimental results show that the bottom PZT sensor can detect the signal when the grout level increases towards 50%, when a conduit between the SA and PZT sensor is formed. The top PZT sensors cannot receive any signal until the grout process is completely finished. The wavelet packet-based energy analysis was adopted in this research to compute the total signal energy received by PZT sensors. Experimental results show that the energy levels of the PZT sensors can reflect the degree of grouting compactness in the duct. The proposed method has the potential to be implemented to monitor the tendon duct grouting compactness of the reinforced concrete structures with post tensioning. PMID:27556470

  8. Ablating hedgehog signaling in tenocytes during development impairs biomechanics and matrix organization of the adult murine patellar tendon enthesis.

    PubMed

    Breidenbach, Andrew P; Aschbacher-Smith, Lindsey; Lu, Yinhui; Dyment, Nathaniel A; Liu, Chia-Feng; Liu, Han; Wylie, Chris; Rao, Marepalli; Shearn, Jason T; Rowe, David W; Kadler, Karl E; Jiang, Rulang; Butler, David L

    2015-08-01

    Restoring the native structure of the tendon enthesis, where collagen fibers of the midsubstance are integrated within a fibrocartilaginous structure, is problematic following injury. As current surgical methods fail to restore this region adequately, engineers, biologists, and clinicians are working to understand how this structure forms as a prerequisite to improving repair outcomes. We recently reported on the role of Indian hedgehog (Ihh), a novel enthesis marker, in regulating early postnatal enthesis formation. Here, we investigate how inactivating the Hh pathway in tendon cells affects adult (12-week) murine patellar tendon (PT) enthesis mechanics, fibrocartilage morphology, and collagen fiber organization. We show that ablating Hh signaling resulted in greater than 100% increased failure insertion strain (0.10 v. 0.05 mm/mm, p<0.01) as well as sub-failure biomechanical deficiencies. Although collagen fiber orientation appears overtly normal in the midsubstance, ablating Hh signaling reduces mineralized fibrocartilage by 32%, leading to less collagen embedded within mineralized tissue. Ablating Hh signaling also caused collagen fibers to coalesce at the insertion, which may explain in part the increased strains. These results indicate that Ihh signaling plays a critical role in the mineralization process of fibrocartilaginous entheses and may be a novel therapeutic to promote tendon-to-bone healing. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  9. Collagen V expression is crucial in regional development of the supraspinatus tendon.

    PubMed

    Connizzo, Brianne K; Adams, Sheila M; Adams, Thomas H; Birk, David E; Soslowsky, Louis J

    2016-12-01

    Manipulations in cell culture and mouse models have demonstrated that reduction of collagen V results in altered fibril structure and matrix assembly. A tissue-dependent role for collagen V in determining mechanical function was recently established, but its role in determining regional properties has not been addressed. The objective of this study was to define the role(s) of collagen V expression in establishing the site-specific properties of the supraspinatus tendon. The insertion and midsubstance of tendons from wild type, heterozygous and tendon/ligament-specific null mice were assessed for crimp morphology, fibril morphology, cell morphology, as well as total collagen and pyridinoline cross-link (PYD) content. Fibril morphology was altered at the midsubstance of both groups with larger, but fewer, fibrils and no change in cell morphology or collagen compared to the wild type controls. In contrast, a significant disruption of fibril assembly was observed at the insertion site of the null group with the presence of structurally aberrant fibrils. Alterations were also present in cell density and PYD content. Altogether, these results demonstrate that collagen V plays a crucial role in determining region-specific differences in mouse supraspinatus tendon structure. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:2154-2161, 2016. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  10. Faster Movement Speed Results in Greater Tendon Strain during the Loaded Squat Exercise

    PubMed Central

    Earp, Jacob E.; Newton, Robert U.; Cormie, Prue; Blazevich, Anthony J.

    2016-01-01

    Introduction: Tendon dynamics influence movement performance and provide the stimulus for long-term tendon adaptation. As tendon strain increases with load magnitude and decreases with loading rate, changes in movement speed during exercise should influence tendon strain. Methods: Ten resistance-trained men [squat one repetition maximum (1RM) to body mass ratio: 1.65 ± 0.12] performed parallel-depth back squat lifts with 60% of 1RM load at three different speeds: slow fixed-tempo (TS: 2-s eccentric, 1-s pause, 2-s concentric), volitional-speed without a pause (VS) and maximum-speed jump (JS). In each condition joint kinetics, quadriceps tendon length (LT), patellar tendon force (FT), and rate of force development (RFDT) were estimated using integrated ultrasonography, motion-capture, and force platform recordings. Results: Peak LT, FT, and RFDT were greater in JS than TS (p < 0.05), however no differences were observed between VS and TS. Thus, moving at faster speeds resulted in both greater tendon stress and strain despite an increased RFDT, as would be predicted of an elastic, but not a viscous, structure. Temporal comparisons showed that LT was greater in TS than JS during the early eccentric phase (10–14% movement duration) where peak RFDT occurred, demonstrating that the tendon's viscous properties predominated during initial eccentric loading. However, during the concentric phase (61–70 and 76–83% movement duration) differing FT and similar RFDT between conditions allowed for the tendon's elastic properties to predominate such that peak tendon strain was greater in JS than TS. Conclusions: Based on our current understanding, there may be an additional mechanical stimulus for tendon adaptation when performing large range-of-motion isoinertial exercises at faster movement speeds. PMID:27630574

  11. A Fibre-Reinforced Poroviscoelastic Model Accurately Describes the Biomechanical Behaviour of the Rat Achilles Tendon

    PubMed Central

    Heuijerjans, Ashley; Matikainen, Marko K.; Julkunen, Petro; Eliasson, Pernilla; Aspenberg, Per; Isaksson, Hanna

    2015-01-01

    Background Computational models of Achilles tendons can help understanding how healthy tendons are affected by repetitive loading and how the different tissue constituents contribute to the tendon’s biomechanical response. However, available models of Achilles tendon are limited in their description of the hierarchical multi-structural composition of the tissue. This study hypothesised that a poroviscoelastic fibre-reinforced model, previously successful in capturing cartilage biomechanical behaviour, can depict the biomechanical behaviour of the rat Achilles tendon found experimentally. Materials and Methods We developed a new material model of the Achilles tendon, which considers the tendon’s main constituents namely: water, proteoglycan matrix and collagen fibres. A hyperelastic formulation of the proteoglycan matrix enabled computations of large deformations of the tendon, and collagen fibres were modelled as viscoelastic. Specimen-specific finite element models were created of 9 rat Achilles tendons from an animal experiment and simulations were carried out following a repetitive tensile loading protocol. The material model parameters were calibrated against data from the rats by minimising the root mean squared error (RMS) between experimental force data and model output. Results and Conclusions All specimen models were successfully fitted to experimental data with high accuracy (RMS 0.42-1.02). Additional simulations predicted more compliant and soft tendon behaviour at reduced strain-rates compared to higher strain-rates that produce a stiff and brittle tendon response. Stress-relaxation simulations exhibited strain-dependent stress-relaxation behaviour where larger strains produced slower relaxation rates compared to smaller strain levels. Our simulations showed that the collagen fibres in the Achilles tendon are the main load-bearing component during tensile loading, where the orientation of the collagen fibres plays an important role for the tendon’s viscoelastic response. In conclusion, this model can capture the repetitive loading and unloading behaviour of intact and healthy Achilles tendons, which is a critical first step towards understanding tendon homeostasis and function as this biomechanical response changes in diseased tendons. PMID:26030436

  12. Evidence of structurally continuous collagen fibrils in tendons.

    PubMed

    Svensson, Rene B; Herchenhan, Andreas; Starborg, Tobias; Larsen, Michael; Kadler, Karl E; Qvortrup, Klaus; Magnusson, S Peter

    2017-03-01

    Tendons transmit muscle-generated force through an extracellular matrix of aligned collagen fibrils. The force applied by the muscle at one end of a microscopic fibril has to be transmitted through the macroscopic length of the tendon by mechanisms that are poorly understood. A key element in this structure-function relationship is the collagen fibril length. During embryogenesis short fibrils are produced but they grow rapidly with maturation. There is some controversy regarding fibril length in adult tendon, with mechanical data generally supporting discontinuity while structural investigations favor continuity. This study initially set out to trace the full length of individual fibrils in adult human tendons, using serial block face-scanning electron microscopy. But even with this advanced technique the required length could not be covered. Instead a statistical approach was used on a large volume of fibrils in shorter image stacks. Only a single end was observed after tracking 67.5mm of combined fibril lengths, in support of fibril continuity. To shed more light on this observation, the full length of a short tendon (mouse stapedius, 125μm) was investigated and continuity of individual fibrils was confirmed. In light of these results, possible mechanisms that could reconcile the opposing findings on fibril continuity are discussed. Connective tissues hold all parts of the body together and are mostly constructed from thin threads of the protein collagen (called fibrils). Connective tissues provide mechanical strength and one of the most demanding tissues in this regard are tendons, which transmit the forces generated by muscles. The length of the collagen fibrils is essential to the mechanical strength and to the type of damage the tissue may experience (slippage of short fibrils or breakage of longer ones). This in turn is important for understanding the repair processes after such damage occurs. Currently the issue of fibril length is contentious, but this study provides evidence that the fibrils are extremely long and likely continuous. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  13. Sonographically Guided Plantaris Tendon Release: A Cadaveric Validation Study.

    PubMed

    Smith, Jay; Alfredson, Håkan; Masci, Lorenzo; Sellon, Jacob L; Woods, Charonn D

    2018-06-13

    The plantaris tendon (PT) has been implicated in the pathogenesis of symptoms in a subset of patients with Achilles region pain syndromes and has been traditionally managed via open surgical resection. Although the PT can be visualized on ultrasound, a minimally invasive technique for sonographically guided PT release has not been formally described. To validate a technique to perform sonographically guided PT release in an unembalmed cadaveric model. Prospective, cadaveric laboratory investigation. Procedural skills laboratory in a tertiary medical center. Twenty unembalmed cadaveric knee-ankle-foot specimens (10 right, 10 left; 6 male, 10 female) from 16 donors ages 55-96 years (mean 82.6 years) with BMI's of 14.1 to 33.2 kg/m 2 (mean 23.3 kg/m 2 ). Following simulated local anesthesia and sonographically guided hydrodissection of the plantaris tendon-Achilles tendon interval, a single experienced operator performed sonographically guided PT release on each specimen using an in-plane, lateral to medial approach, a commercially available, disposable 3.0 mm hook knife, and either a 17-5 MHz or 15-7 MHz linear array transducer. Each specimen was subsequently dissected to assess for PT release and iatrogenic injury. Status of the PT, Achilles tendon, and regional neurovascular structures as determined by dissection. All 20 PT releases were completed in a single attempt through a 3-5 mm incision. Dissection confirmed complete PT release in all specimens without damage to the adjacent Achilles tendon or regional neurovascular structures. Sonographically guided PT release is technically feasible and can be performed while avoiding injury to the Achilles tendon and regional neurovascular structures. Additional research is warranted to further define the role of sonographically guided PT release in patients with suspected PT-mediated Achilles region pain syndromes. Copyright © 2018 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  14. Elastic fibres are broadly distributed in tendon and highly localized around tenocytes

    PubMed Central

    Grant, Tyler M; Thompson, Mark S; Urban, Jill; Yu, Jing

    2013-01-01

    Elastic fibres have the unique ability to withstand large deformations and are found in numerous tissues, but their organization and structure have not been well defined in tendon. The objective of this study was to characterize the organization of elastic fibres in tendon to understand their function. Immunohistochemistry was used to visualize elastic fibres in bovine flexor tendon with fibrillin-1, fibrillin-2 and elastin antibodies. Elastic fibres were broadly distributed throughout tendon, and highly localized longitudinally around groups of cells and transversely between collagen fascicles. The close interaction of elastic fibres and cells suggests that elastic fibres are part of the pericellular matrix and therefore affect the mechanical environment of tenocytes. Fibres present between fascicles are likely part of the endotenon sheath, which enhances sliding between adjacent collagen bundles. These results demonstrate that elastic fibres are highly localized in tendon and may play an important role in cellular function and contribute to the tissue mechanics of the endotenon sheath. PMID:23587025

  15. Isolation and characterization of 2 new human rotator cuff and long head of biceps tendon cells possessing stem cell-like self-renewal and multipotential differentiation capacity.

    PubMed

    Randelli, Pietro; Conforti, Erika; Piccoli, Marco; Ragone, Vincenza; Creo, Pasquale; Cirillo, Federica; Masuzzo, Pamela; Tringali, Cristina; Cabitza, Paolo; Tettamanti, Guido; Gagliano, Nicoletta; Anastasia, Luigi

    2013-07-01

    Stem cell therapy is expected to offer new alternatives to the traditional therapies of rotator cuff tendon tears. In particular, resident, tissue-specific, adult stem cells seem to have a higher regenerative potential for the tissue where they reside. Rotator cuff tendon and long head of the biceps tendon possess a resident stem cell population that, when properly stimulated, may be induced to proliferate, thus being potentially usable for tendon regeneration. Controlled laboratory study. Human tendon samples from the supraspinatus and the long head of the biceps were collected during rotator cuff tendon surgeries from 26 patients, washed with phosphate-buffered saline, cut into small pieces, and digested with collagenase type I and dispase. After centrifugation, cell pellets were resuspended in appropriate culture medium and plated. Adherent cells were cultured, phenotypically characterized, and then compared with human bone marrow stromal cells (BMSCs), as an example of adult stem cells, and human dermal fibroblasts, as normal proliferating cells with no stem cell properties. Two new adult stem cell populations from the supraspinatus and long head of the biceps tendons were isolated, characterized, and cultured in vitro. Cells showed adult stem cell characteristics (ie, they were self-renewing in vitro, clonogenic, and multipotent), as they could be induced to differentiate into different cell types--namely, osteoblasts, adipocytes, and skeletal muscle cells. This work demonstrated that human rotator cuff tendon stem cells and human long head of the biceps tendon stem cells can be isolated and possess a high regenerative potential, which is comparable with that of BMSCs. Moreover, comparative analysis of the sphingolipid pattern of isolated cells with that of BMSCs and fibroblasts revealed the possibility of using this class of lipids as new possible markers of the cell differentiation status. Rotator cuff and long head of the biceps tendons contain a stem cell population that can proliferate in vitro and could constitute an easily accessible stem cell source to develop novel therapies for tendon regeneration.

  16. Non-linear visco-elastic analysis and the design of super-pressure balloons : stress, strain and stability

    NASA Astrophysics Data System (ADS)

    Wakefield, David

    Tensys have a long-established background in the shape generation and load analysis of architectural stressed membrane structures. Founded upon their inTENS finite element analysis suite, these activities have broadened to encompass ‘lighter than air' structures such as aerostats, hybrid air-vehicles and stratospheric balloons. Since 2004 Tensys have acted as consultants to the NASA Ultra Long Duration Balloon (ULDB) Program. Early implementations of the super-pressure balloon design chosen for ULDB have shown problems of geometric instability, characterised by improper deployment and the potential for overall geometric instability once deployed. The latter has been reproduced numerically using inTENS, and the former are better understood following a series of large-scale hangar tests simulating launch and ascent. In both cases the solution lies in minimising the film lobing between the tendons. These tendons, which span between base and apex end fittings, cause the characteristic pumpkin shape of the balloons and also provide valuable constraint against excessive film deformation. There is also the requirement to generate a biaxial stress field in order to mobilise in-plane shear stiffness. A consequence of reduced lobing between tendons is the development of higher stresses in the balloon film under pressure. The different thermal characteristics between tendons and film lead to further significant meridional stress under low temperature flight conditions. The non-linear viscoelastic response of the envelope film acts positively to help dissipate excessive stress and local concentrations. However, creep over time may produce lobe geometry variations sufficient to compromise the geometric stability of the balloon. The design of a balloon requires an analysis approach that addresses the questions of stress and stability over the duration of a flight by time stepping analyses using an appropriate material model. This paper summarises the Dynamic Relaxation approach to stress and stability analysis inherent in inTENS, and focuses in particular on: Implementation of an alternative application of the Incremental Schapery Rand (ISR) representation of the non-linear visco-elastic response of the polyethylene balloon film. This is based upon the relaxation modulus, rather than the creep compliance, and as such fits more efficiently into the Dynamic Relaxation analysis procedure used within inTENS. Comparisons of results between the two approaches are given. Verification of the material model by comparison with material tests. Verification of the application to pumpkin balloon structures by comparison with scale model tests. Application of inTENS with ISR to time-stepping analyses of a balloon flight including diurnal variations of temperature and pressure. This includes the demonstration of a method for checking the likely hood of overall instability developing at any particular time in the flight as both balloon geometry and film properties change due to visco-elastic effects.

  17. Acute effects of constant torque and constant angle stretching on the muscle and tendon tissue properties.

    PubMed

    Konrad, Andreas; Budini, Francesco; Tilp, Markus

    2017-08-01

    Static stretching induces acute structural changes of the muscle-tendon unit (MTU) that are related to the intensity or duration of stretching. It has been reported that stretching with a constant torque (CT) leads to greater joint range of motion changes than stretching with a constant angle (CA). Whether or not this difference is due to different structural changes of the MTUs of the lower leg and ankle plantar flexors is not known. Therefore, the purpose of this study was to compare the acute effects of single CA and CT stretching on various muscle and tendon mechanical properties. Seventeen young, healthy volunteers were tested on two separate days using either CT or CA stretching (4 × 30 s each). Before and after stretching, dorsiflexion range of motion (RoM), passive resistive torque (PRT), and maximum voluntary contraction (MVC) were measured with a dynamometer. Ultrasonography of the medial gastrocnemius (GM) muscle-tendon junction (MTJ) displacement allowed us to determine the length changes in the tendon and muscle, respectively, and hence to calculate their stiffness. Maximum dorsiflexion increased while PRT, muscle-tendon stiffness, and muscle stiffness decreased following both CA and CT stretching. There was a greater increase in RoM following CT stretching compared to CA stretching. Moreover, the decline in PRT was greater during CT stretching compared to CA stretching. As expected, several functional adaptations (RoM, PRT) were different between CT and CA stretching due to the higher intensity of CT stretching. However, no structural differences in the adaptations to the stretching modalities could be detected. We suggest that the different functional adaptations between CA and CT stretching are the consequence of different adaptations in the perception of stretch and pain.

  18. The effect of exercise repetition on the frequency characteristics of motor output force: implications for Achilles tendinopathy rehabilitation.

    PubMed

    Grigg, Nicole L; Wearing, Scott C; O'Toole, John M; Smeathers, James E

    2014-01-01

    To investigate the frequency characteristics of the ground reaction force (GRF) recorded throughout the eccentric Achilles tendon rehabilitation programme described by Alfredson. Controlled laboratory study, longitudinal. Nine healthy adult males performed six sets (15 repetitions per set) of eccentric ankle exercise. Ground reaction force was recorded throughout the exercise protocol. For each exercise repetition the frequency power spectrum of the resultant ground reaction force was calculated and normalised to total power. The magnitude of peak relative power within the 8-12 Hz bandwidth and the frequency at which this peak occurred was determined. The magnitude of peak relative power within the 8-12 Hz bandwidth increased with each successive exercise set and following the 4th set (60 repetitions) of exercise the frequency at which peak relative power occurred shifted from 9 to 10 Hz. The increase in magnitude and frequency of ground reaction force vibrations with an increasing number of exercise repetitions is likely connected to changes in muscle activation with fatigue and tendon conditioning. This research illustrates the potential for the number of exercise repetitions performed to influence the tendons' mechanical environment, with implications for tendon remodelling and the clinical efficacy of eccentric rehabilitation programmes for Achilles tendinopathy. Copyright © 2013 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  19. Repair of full-thickness tendon injury using connective tissue progenitors efficiently derived from human embryonic stem cells and fetal tissues.

    PubMed

    Cohen, Shahar; Leshansky, Lucy; Zussman, Eyal; Burman, Michael; Srouji, Samer; Livne, Erella; Abramov, Natalie; Itskovitz-Eldor, Joseph

    2010-10-01

    The use of stem cells for tissue engineering (TE) encourages scientists to design new platforms in the field of regenerative and reconstructive medicine. Human embryonic stem cells (hESC) have been proposed to be an important cell source for cell-based TE applications as well as an exciting tool for investigating the fundamentals of human development. Here, we describe the efficient derivation of connective tissue progenitors (CTPs) from hESC lines and fetal tissues. The CTPs were significantly expanded and induced to generate tendon tissues in vitro, with ultrastructural characteristics and biomechanical properties typical of mature tendons. We describe a simple method for engineering tendon grafts that can successfully repair injured Achilles tendons and restore the ankle joint extension movement in mice. We also show the CTP's ability to differentiate into bone, cartilage, and fat both in vitro and in vivo. This study offers evidence for the possibility of using stem cell-derived engineered grafts to replace missing tissues, and sets a basic platform for future cell-based TE applications in the fields of orthopedics and reconstructive surgery.

  20. [Tendinopathy in rheumatic diseases].

    PubMed

    Henniger, M; Rehart, S

    2017-03-01

    Involvement of tendons and tendon sheaths is frequently found in the most common inflammatory systemic diseases, rheumatoid arthritis and spondyloarthritis. In rheumatoid arthritis tendon manifestations occur as tenosynovitis, with swelling and pain of the tendons mainly on the hands and feet. In spondyloarthritis the involvement of tendons presents as enthesitis with pain and swelling directly at the attachment points of tendons to the bony structures and more commonly in the lower extremities. Pathological alterations of tendons can be normally visualized by sonography and only sometimes with magnetic resonance imaging (MRI) or scintigraphy. Furthermore, it is important for diagnostics and effective therapy to detect all joints involved by means of clinical, sonographic and radiological examination as well as laboratory parameters of inflammation, antibody serology (e.g. anti-CCP antibodies) and HLA-B27. The histopathological alterations of tendinopathy in rheumatic diseases differ from degenerative/posttraumatic tendinopathy in their expression of the changes; however, a clear differentiation of the different rheumatic inflammatory systemic diseases is histopathologically not possible. Therapeutically, systemic medication is the most important part of treatment in rheumatic diseases. Local therapeutic measures can be employed in the treatment of tenosynovitis and enthesitis. In the case of failure or lack of efficacy of the medication and conservative therapy, tenosynovectomy is performed for persistent tenosynovitis and reconstructive surgical procedures are necessary for tendon ruptures.

  1. [Giant cell tumor of the tendon sheath: characteristic findings of the bone scintigraphy and correlation with MRI].

    PubMed

    Mena, E; Martín-Miramon, J C; Bernà, L; Veintemillas, M; Marín, A; Valls, R; Melloni, P

    2009-01-01

    We report 3 cases of an unusual tumor, that is, the giant cell tumor of the tendon sheath. The patients consulted due to the appearance of a well-defined, painless, soft tissue mass with mild-to-moderate inflammation located in the thumbs or toes. These clinical data, together with the bone scan findings, oriented the diagnostic suspicion that was confirmed by a pathology study of the tumor after resection. This work has aimed to review the characteristics of the bone scan (BS) image of this tumor and its correlation with the conventional X-ray imaging and magnetic resonance imaging (MRI).

  2. Effects of sodium hyaluronate on tendon healing and adhesion formation in horses.

    PubMed

    Gaughan, E M; Nixon, A J; Krook, L P; Yeager, A E; Mann, K A; Mohammed, H; Bartel, D L

    1991-05-01

    Sodium hyaluronate reduces adhesions after tendon repair in rodents and dogs, and has been used in limited clinical trials in people. To evaluate its effect on tendon healing and adhesion formation in horses and to compare these effects with those of a compound of similar visco-elastic properties, a study was performed in horses, using a model of collagenase injection in the flexor tendons within the digital sheath. Eight clinically normal horses were randomly allotted to 2 groups. Adhesion formation between the deep digital flexor tendon and the tendon sheath at the pastern region was induced in the forelimbs of all horses. Using tenoscopic control, a 20-gauge needle was inserted into the deep digital flexor tendon of horses under general anesthesia and 0.2 ml of collagenase (2.5 mg/ml) was injected. The procedure was repeated proximally at 2 other sites, spaced 1.5 cm apart. A biopsy forceps was introduced, and a 5-mm tendon defect was created at each injection site. Group-A horses had 120 mg of sodium hyaluronate (NaHA) gel injected into the tendon sheath of one limb. Group-B horses had methylcellulose gel injected at the same sites. The contralateral limbs of horses in both groups served as surgical, but noninjected, controls. Horses were euthanatized after 8 weeks of stall rest. Ultrasonographic evaluation revealed improved tendon healing after NaHa injection, but no difference in peritendinous adhesion formation. Tendon sheath fluid volume and hyaluronic acid (HA) content were greater in NaHA-treated limbs. Gross pathologic examination revealed considerably fewer and smaller adhesions when limbs were treated with NaHA. However, significant difference in pull-out strengths was not evident between NaHA-treated and control limbs. Histologically, the deep digital flexor tendon from the NaHA-treated limbs had reduced inflammatory cell infiltration, improved tendon structure, and less intratendinous hemorrhage. Treatment with methylcullulose had no significant effect on tendon healing, adhesion size, quantity, or strength or on the volume and composition of the tendon sheath fluid. Sodium hyaluronate, administered intrathecally, appears to have a pharmaceutically beneficial action in this collagenase-induced tendinitis and adhesion model in horses.

  3. Vascular abnormalities of the distal deep digital flexor tendon in 8 draught horses identified on histological examination.

    PubMed

    Crişan, Melania Ioana; Damian, Aurel; Gal, Adrian; Miclăuş, Viorel; Cernea, Cristina L; Denoix, Jean-Marie

    2013-08-01

    The purpose of this study was to provide a detailed description of the vascular changes in the distal part of deep digital flexor tendon (DDFT). Eight isolated forelimbs were collected from 8 horses with DDF tendinopathy diagnosed post-mortem by ultrasound and gross anatomopathological examination. The samples were fixed in 10% neutral buffered formalin, softened in 4% phenol and dehydrated with ethylic alcohol. Goldner's Trichrome staining method was used. The histopathological examination revealed vascular proliferation associated with structural disorders of blood vessels. Angiogenesis, fibroplasia and consecutive hypertrophy of the vascular wall with or without vascular occlusion were the most common findings. Other histopathological findings were: endothelial cell edema, progressive metaplasia from squamous to cubic cells, vascular wall hyalinization, endothelial cells apoptosis/necrosis and endothelial desquamation. These results demonstrated damage of the distal deep digital flexor tendon vasculature which may progressively alter the structural integrity of the tendon and contribute to degenerative lesions. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Measuring tendon properties in mdx mice: cell viability and viscoelastic characteristics.

    PubMed

    Rizzuto, E; Musarò, A; Catizone, A; Del Prete, Z

    2009-10-16

    Muscular dystrophy is a genetic disorder of skeletal muscle characterized by progressive muscle weakness. Here we assessed whether muscle wasting affects cell viability and mechanical properties of extensor digitorum longus (EDL) and of tibialis anterior (TA) tendons from mdx dystrophic mice compared to wild type (WT) mice. mdx mice represent the classical animal model for human Duchenne muscular dystrophy, and show several signs of the pathology, including a decrease in specific force and an increase of fibrotic index. Cell viability of tendons was evaluated by histological analysis, and viscoelastic properties have been assessed by a rapid measurement protocol that allowed us to compute, at the same time, tissue complex compliance for all the frequencies of interest. Confocal microscopy and mechanical properties measurements revealed that mdx tendons, compared to WT ones, have an increase in the number of dead cells and a significant reduction in tissue elasticity for all the frequencies that were tested. These findings indicate a reduced quality of the tissue. Moreover, mdx tendons have an increase in the viscous response, indicating that during dynamic loading, they dissipate more energy compared to WT. Our results demonstrate that muscular dystrophy involves not only muscle wasting, but also alteration in the viscoelastic properties of tendons, suggesting a paracrine effect of altered skeletal muscle on tendinous tissue.

  5. Failed healing of rotator cuff repair correlates with altered collagenase and gelatinase in supraspinatus and subscapularis tendons.

    PubMed

    Robertson, Catherine M; Chen, Christopher T; Shindle, Michael K; Cordasco, Frank A; Rodeo, Scott A; Warren, Russell F

    2012-09-01

    Despite improvements in arthroscopic rotator cuff repair technique and technology, a significant rate of failed tendon healing persists. Improving the biology of rotator cuff repairs may be an important focus to decrease this failure rate. The objective of this study was to determine the mRNA biomarkers and histological characteristics of repaired rotator cuffs that healed or developed persistent defects as determined by postoperative ultrasound. Increased synovial inflammation and tendon degeneration at the time of surgery are correlated with the failed healing of rotator cuff tendons. Case-control study; Level of evidence, 3. Biopsy specimens from the subscapularis tendon, supraspinatus tendon, glenohumeral synovium, and subacromial bursa of 35 patients undergoing arthroscopic rotator cuff repair were taken at the time of surgery. Expression of proinflammatory cytokines, tissue remodeling genes, and angiogenesis factors was evaluated by quantitative real-time polymerase chain reaction. Histological characteristics of the affected tissue were also assessed. Postoperative (>6 months) ultrasound was used to evaluate the healing of the rotator cuff. General linear modeling with selected mRNA biomarkers was used to predict rotator cuff healing. Thirty patients completed all analyses, of which 7 patients (23%) had failed healing of the rotator cuff. No differences in demographic data were found between the defect and healed groups. American Shoulder and Elbow Surgeons shoulder scores collected at baseline and follow-up showed improvement in both groups, but there was no significant difference between groups. Increased expression of matrix metalloproteinase 1 (MMP-1) and MMP-9 was found in the supraspinatus tendon in the defect group versus the healed group (P = .006 and .02, respectively). Similar upregulation of MMP-9 was also found in the subscapularis tendon of the defect group (P = .001), which was consistent with the loss of collagen organization as determined by histological examination. From a general linear model, the upregulation of MMP-1 and MMP-9 was highly correlated with failed healing of the rotator cuff (R(2) = .656). The upregulation of tissue remodeling genes in the torn rotator cuff at the time of surgery provides a snapshot of the biological environment surrounding the torn rotator cuff that is closely related to the healing of repaired rotator cuffs.

  6. Cell phenotypic variation in normal and damaged tendons

    PubMed Central

    Clegg, Peter D; Strassburg, Sandra; Smith, Roger K

    2007-01-01

    Injuries to tendons are common in both human athletes as well as in animals, such as the horse, which are used for competitive purposes. Furthermore, such injuries are also increasing in prevalence in the ageing, sedentary population. Tendon diseases often respond poorly to treatment and require lengthy periods of rehabilitation. The tendon has a unique extracellular matrix, which has developed to withstand the mechanical demands of such tensile-load bearing structures. Following injury, any repair process is inadequate and results in tissue that is distinct from original tendon tissue. There is growing evidence for the key role of the tendon cell (tenocyte) in both the normal physiological homeostasis and regulation of the tendon matrix and the pathological derangements that occur in disease. In particular, the tenocyte is considered to have a major role in effecting the subclinical matrix degeneration that is thought to occur prior to clinical disease, as well as in the severe degradative events that occur in the tendon at the onset of clinical disease. Furthermore, the tenocyte is likely to have a central role in the production of the biologically inadequate fibrocartilaginous repair tissue that develops subsequent to tendinopathy. Understanding the biology of the tenocyte is central to the development of appropriate interventions and drug therapies that will either prevent the onset of disease, or lead to more rapid and appropriate repair of injured tendon. Central to this is a full understanding of the proteolytic response in the tendon in disease by such enzymes as metalloproteinases, as well as the control of the inappropriate fibrocartilaginous differentiation. Finally, it is important that we understand the role of both intrinsic and extrinsic cellular elements in the repair process in the tendon subsequent to injury. PMID:17696903

  7. The study of optical properties and proteoglycan content of tendons by PS-OCT

    NASA Astrophysics Data System (ADS)

    Yang, Ying; Rupani, Asha; Weightman, Alan; Wimpenny, Ian; Bagnaninchi, Pierre; Ahearne, Mark

    2011-03-01

    Tendons are load-bearing collagenous tissues consisting mainly of type I collagen and various proteoglycans (PGs) including decorin and versican. It is widely accepted that highly orientated collagen fibers in tendons a play critical role for transferring tensile stress and demonstrate birefringent optical properties. However, the influence that proteoglycans have on the optical properties of tendons is yet to be fully elucidated. Tendinopathy (defined as a syndrome of tendon pain, tenderness and swelling that affects the normal function of the tissue) is a common disease associated with sporting injuries or degeneration. PG's are the essential components of the tendon extracellular matrix; changes in their quantities and compositions have been associated with tendinopathy. In this study, polarization sensitive optical coherence tomography (PS-OCT) has been used to reveal the relationship between proteoglycan content/location and birefringent properties of tendons. Tendons dissected from freshly slaughtered chickens were imaged at regular intervals by PS-OCT and polarizing light microscope during the extraction of PGs or glycosaminoglycans using established protocols (guanidine hydrochloride (GuHCl) or proteinase K solution). The macroscopic and microscopic time lapsed images are complimentary; mutually demonstrating that there was a higher concentration of PG's in the outer sheath region than in the fascicles; and the integrity of the sheath affected extraction process and the OCT birefringence bands. Extraction of PGs using GuHCl disturbed the organization of local collagen bundles, which corresponded to a reduction in the frequency of birefringence bands and the band width by PS-OCT. The feature of OCT penetration depth helped us to define the heterogeneous distribution of PG's in tendon, which was complimented by polarizing light microscopy. The results provide new insight of tendon structure and also demonstrate a great potential for using PS-OCT as a diagnostic tool to examine tendon pathology.

  8. Tendon neuroplastic training: changing the way we think about tendon rehabilitation: a narrative review

    PubMed Central

    Rio, Ebonie; Kidgell, Dawson; Moseley, G Lorimer; Docking, Sean; Purdam, Craig; Cook, Jill

    2016-01-01

    Tendinopathy can be resistant to treatment and often recurs, implying that current treatment approaches are suboptimal. Rehabilitation programmes that have been successful in terms of pain reduction and return to sport outcomes usually include strength training. Muscle activation can induce analgesia, improving self-efficacy associated with reducing one's own pain. Furthermore, strength training is beneficial for tendon matrix structure, muscle properties and limb biomechanics. However, current tendon rehabilitation may not adequately address the corticospinal control of the muscle, which may result in altered control of muscle recruitment and the consequent tendon load, and this may contribute to recalcitrance or symptom recurrence. Outcomes of interest include the effect of strength training on tendon pain, corticospinal excitability and short interval cortical inhibition. The aims of this concept paper are to: (1) review what is known about changes to the primary motor cortex and motor control in tendinopathy, (2) identify the parameters shown to induce neuroplasticity in strength training and (3) align these principles with tendon rehabilitation loading protocols to introduce a combination approach termed as tendon neuroplastic training. Strength training is a powerful modulator of the central nervous system. In particular, corticospinal inputs are essential for motor unit recruitment and activation; however, specific strength training parameters are important for neuroplasticity. Strength training that is externally paced and akin to a skilled movement task has been shown to not only reduce tendon pain, but modulate excitatory and inhibitory control of the muscle and therefore, potentially tendon load. An improved understanding of the methods that maximise the opportunity for neuroplasticity may be an important progression in how we prescribe exercise-based rehabilitation in tendinopathy for pain modulation and potentially restoration of the corticospinal control of the muscle-tendon complex. PMID:26407586

  9. Anatomy and histology of the transverse humeral ligament.

    PubMed

    Snow, Brian J; Narvy, Steven J; Omid, Reza; Atkinson, Roscoe D; Vangsness, C Thomas

    2013-10-01

    The classic literature describes the transverse humeral ligament (THL) as a distinct anatomic structure with a role in biceps tendon stability; however, recent literature suggests that it is not a distinct anatomic structure. The purpose of this study was to evaluate the gross and microscopic anatomy of the THL, including a specific investigation of the histology of this ligament. Thirty frozen, embalmed cadaveric specimens were dissected to determine the gross anatomy of the THL. Seven specimens were evaluated histologically for the presence of mechanoreceptors and free nerve endings. Two tissue layers were identified in the area described as the THL. In the deep layer, fibers of the subscapularis tendon were found to span the bicipital groove with contributions from the coracohumeral ligament and the supraspinatus tendon. Superficial to this layer was a fibrous fascial covering consisting of distinct bands of tissue. Neurohistology staining revealed the presence of free nerve endings but no mechanoreceptors. This study's findings demonstrate that the THL is a distinct structure continuous with the rotator cuff tendons and the coracohumeral ligament. The finding of free nerve endings in the THL suggests a potential role as a shoulder pain generator. Copyright 2013, SLACK Incorporated.

  10. Frequency characteristics of human muscle and cortical responses evoked by noisy Achilles tendon vibration.

    PubMed

    Mildren, Robyn L; Peters, Ryan M; Hill, Aimee J; Blouin, Jean-Sébastien; Carpenter, Mark G; Inglis, J Timothy

    2017-05-01

    Noisy stimuli, along with linear systems analysis, have proven to be effective for mapping functional neural connections. We explored the use of noisy (10-115 Hz) Achilles tendon vibration to examine somatosensory reflexes in the triceps surae muscles in standing healthy young adults ( n = 8). We also examined the association between noisy vibration and electrical activity recorded over the sensorimotor cortex using electroencephalography. We applied 2 min of vibration and recorded ongoing muscle activity of the soleus and gastrocnemii using surface electromyography (EMG). Vibration amplitude was varied to characterize reflex scaling and to examine how different stimulus levels affected postural sway. Muscle activity from the soleus and gastrocnemii was significantly correlated with the tendon vibration across a broad frequency range (~10-80 Hz), with a peak located at ~40 Hz. Vibration-EMG coherence positively scaled with stimulus amplitude in all three muscles, with soleus displaying the strongest coupling and steepest scaling. EMG responses lagged the vibration by ~38 ms, a delay that paralleled observed response latencies to tendon taps. Vibration-evoked cortical oscillations were observed at frequencies ~40-70 Hz (peak ~54 Hz) in most subjects, a finding in line with previous reports of sensory-evoked γ-band oscillations. Further examination of the method revealed 1 ) accurate reflex estimates could be obtained with <60 s of low-level (root mean square = 10 m/s 2 ) vibration; 2 ) responses did not habituate over 2 min of exposure; and importantly, 3 ) noisy vibration had a minimal influence on standing balance. Our findings suggest noisy tendon vibration is an effective novel approach to characterize somatosensory reflexes during standing. NEW & NOTEWORTHY We applied noisy (10-115 Hz) vibration to the Achilles tendon to examine the frequency characteristics of lower limb somatosensory reflexes during standing. Ongoing muscle activity was coherent with the noisy vibration (peak coherence ~40 Hz), and coherence positively scaled with increases in stimulus amplitude. Our findings suggest that noisy tendon vibration, along with linear systems analysis, is an effective novel approach to study somatosensory reflex actions in active muscles. Copyright © 2017 the American Physiological Society.

  11. Differences in tendon properties in elite badminton players with or without patellar tendinopathy.

    PubMed

    Couppé, C; Kongsgaard, M; Aagaard, P; Vinther, A; Boesen, M; Kjaer, M; Magnusson, S P

    2013-03-01

    The aim of this study was to examine the structural and mechanical properties of the patellar tendon in elite male badminton players with and without patellar tendinopathy. Seven players with unilateral patellar tendinopathy (PT group) on the lead extremity (used for forward lunge) and nine players with no current or previous patellar tendinopathy (CT group) were included. Magnetic resonance imaging was used to assess distal patellar tendon dimensions. Patellar tendon mechanical properties were assessed using simultaneous tendon force and deformation measurements. Distal tendon cross-sectional area (CSA) normalized for body weight (mm(2) /kg(2/3) ) was lower in the PT group compared with the CT group on both the non-lead extremity (6.1 ± 0.3 vs 7.4 ± 0.2, P < 0.05) and the lead extremity (6.5 ± 0.6 vs 8.4 ± 0.3, P < 0.05). Distal tendon stress was higher in the PT group compared with the CT group for both the non-lead extremity (31 ± 1 vs 27 ± 1 MPa, P < 0.05) and the lead extremity (32 ± 3 vs 21 ± 3 MPa, P < 0.01). Conclusively, the PT group had smaller distal patellar tendon CSA on both the injured (lead extremity) and the uninjured side (non-lead extremity) compared with the CT group. Subsequently, the smaller CSA yielded a greater distal patellar tendon stress in the PT group. Therefore, a small tendon CSA may predispose to the development of tendinopathy. © 2012 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

  12. Cellular therapy in bone-tendon interface regeneration

    PubMed Central

    Rothrauff, Benjamin B; Tuan, Rocky S

    2014-01-01

    The intrasynovial bone-tendon interface is a gradual transition from soft tissue to bone, with two intervening zones of uncalcified and calcified fibrocartilage. Following injury, the native anatomy is not restored, resulting in inferior mechanical properties and an increased risk of re-injury. Recent in vivo studies provide evidence of improved healing when surgical repair of the bone-tendon interface is augmented with cells capable of undergoing chondrogenesis. In particular, cellular therapy in bone-tendon healing can promote fibrocartilage formation and associated improvements in mechanical properties. Despite these promising results in animal models, cellular therapy in human patients remains largely unexplored. This review highlights the development and structure-function relationship of normal bone-tendon insertions. The natural healing response to injury is discussed, with subsequent review of recent research on cellular approaches for improved healing. Finally, opportunities for translating in vivo findings into clinical practice are identified. PMID:24326955

  13. Treatment with vacuum-assisted closure and cryo-preserved homologous de-epidermalised dermis of complex traumas to the lower limbs with loss of substance, and bones and tendons exposure.

    PubMed

    Brandi, C; Grimaldi, L; Nisi, G; Silvestri, A; Brafa, A; Calabrò, M; D'Aniello, C

    2008-12-01

    Lower-limb injuries with loss of tissue and exposure of bones and tendons are an increasing problem. The condition of the wound locally and the patient in general does not always allow immediate and adequate coverage of the structures exposed by the trauma. Therefore, new therapeutic solutions are needed. A reduction in the time that bones and tendons are exposed is essential to achieve complete healing of bone fractures, with reduced risks of infection and less disabling outcomes. The effectiveness of vacuum-assisted closure (VAC) therapy in supporting wound healing and of cryopreserved homologous de-epidermalised dermis (DED) in providing an effective template for re-epithelialisation has been previously reported. We carried out a study to evaluate the effectiveness of the synergistic and combined use of the two methodologies. Eighteen patients with traumatic loss of tissue in the lower limbs, involving exposure of bone and tendon structures, were enrolled in the study. All participants had local, general contraindications to first-instance reconstructions, or both. All patients received a combination of VAC therapy and DED implants. Granulation tissue was obtained in all wounds, with complete coverage of exposed structures. No infections were detected in the cohort, and all patients were prepared for further necessary reconstructive treatments. In our experience, the combination of VAC therapy and DED could, in selected cases, constitute an effective treatment for complex lower limb traumatic injuries with bone and tendon exposure.

  14. Do postoperative platelet-rich plasma injections accelerate early tendon healing and functional recovery after arthroscopic supraspinatus repair? A randomized controlled trial.

    PubMed

    Wang, Allan; McCann, Philip; Colliver, Jess; Koh, Eamon; Ackland, Timothy; Joss, Brendan; Zheng, Minghao; Breidahl, Bill

    2015-06-01

    Tendon-bone healing after rotator cuff repair directly correlates with a successful outcome. Biological therapies that elevate local growth-factor concentrations may potentiate healing after surgery. To ascertain whether postoperative and repeated application of platelet-rich plasma (PRP) to the tendon repair site improves early tendon healing and enhances early functional recovery after double-row arthroscopic supraspinatus repair. Randomized controlled trial; Level of evidence, 1. A total of 60 patients underwent arthroscopic double-row supraspinatus tendon repair. After randomization, half the patients received 2 ultrasound-guided injections of PRP to the repair site at postoperative days 7 and 14. Early structural healing was assessed with MRI at 16 weeks, and cuff appearances were graded according to the Sugaya classification. Functional scores were recorded with the Oxford Shoulder Score; Quick Disability of the Arm, Shoulder and Hand; visual analog scale for pain; and Short Form-12 quality-of-life score both preoperatively and at postoperative weeks 6, 12, and 16; isokinetic strength and active range of motion were measured at 16 weeks. PRP treatment did not improve early functional recovery, range of motion, or strength or influence pain scores at any time point after arthroscopic supraspinatus repair. There was no difference in structural integrity of the supraspinatus repair on MRI between the PRP group (0% full-thickness retear; 23% partial tear; 77% intact) and the control group (7% full-thickness retear; 23% partial tear; 70% intact) at 16 weeks postoperatively (P = .35). After arthroscopic supraspinatus tendon repair, image-guided PRP treatment on 2 occasions does not improve early tendon-bone healing or functional recovery. © 2015 The Author(s).

  15. Musculoskeletal modelling of human ankle complex: Estimation of ankle joint moments.

    PubMed

    Jamwal, Prashant K; Hussain, Shahid; Tsoi, Yun Ho; Ghayesh, Mergen H; Xie, Sheng Quan

    2017-05-01

    A musculoskeletal model for the ankle complex is vital in order to enhance the understanding of neuro-mechanical control of ankle motions, diagnose ankle disorders and assess subsequent treatments. Motions at the human ankle and foot, however, are complex due to simultaneous movements at the two joints namely, the ankle joint and the subtalar joint. The musculoskeletal elements at the ankle complex, such as ligaments, muscles and tendons, have intricate arrangements and exhibit transient and nonlinear behaviour. This paper develops a musculoskeletal model of the ankle complex considering the biaxial ankle structure. The model provides estimates of overall mechanical characteristics (motion and moments) of ankle complex through consideration of forces applied along ligaments and muscle-tendon units. The dynamics of the ankle complex and its surrounding ligaments and muscle-tendon units is modelled and formulated into a state space model to facilitate simulations. A graphical user interface is also developed during this research in order to include the visual anatomical information by converting it to quantitative information on coordinates. Validation of the ankle model was carried out by comparing its outputs with those published in literature as well as with experimental data obtained from an existing parallel ankle rehabilitation robot. Qualitative agreement was observed between the model and measured data for both, the passive and active ankle motions during trials in terms of displacements and moments. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. P2 porous titanium implants improve tendon healing in an acute rat supraspinatus repair model.

    PubMed

    Tucker, Jennica J; Gordon, Joshua A; Zanes, Robert C; Zuskov, Andrey; Vinciguerra, John D; Bloebaum, Roy D; Soslowsky, Louis J

    2017-03-01

    Current techniques in rotator cuff repair often lack structural integrity. P 2 porous titanium-coated constructs (DJO Surgical, Austin, TX, USA) promote osseointegration and soft tissue ingrowth. This study examined the ability of this material to improve the structural integrity of supraspinatus tendon repair in a rat model. We hypothesized that P 2 implants placed at the tendon-to-bone interface would improve mechanical and histologic measures of supraspinatus healing. Forty rats underwent supraspinatus repairs with P 2 implants in 1 shoulder and standard repair in the other. Rats were humanely killed at time 0 (n = 3), 2 weeks (n = 8), 4 weeks (n = 15), and 12 weeks (n = 14). Tendon-to-bone composite specimens were harvested and evaluated mechanically and histologically. Tendon cross-sectional area was decreased in the P 2 implant group at 4 weeks, percentage of relaxation was increased at 2 weeks, elastic modulus was increased at 4 weeks, and maximum load and maximum stress were both increased at 2 and 4 weeks. Histologic analysis revealed no foreign body reactions within or around the P 2 implant, and healthy viable bone was visible within the P 2 implant. The results support our hypothesis, specifically in early healing, in this randomized controlled animal study. These data support the use of P 2 porous titanium implants to improve tendon-to-bone healing. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  17. Marked pathological changes proximal and distal to the site of rupture in acute Achilles tendon ruptures.

    PubMed

    Maffulli, Nicola; Longo, Umile Giuseppe; Maffulli, Gayle D; Rabitti, Carla; Khanna, Anil; Denaro, Vincenzo

    2011-04-01

    A laboratory study was performed to evaluate the histopathological features of the macroscopically intact portion of the Achilles tendon in patients undergoing surgery for an acute rupture of the Achilles tendon. Tendon samples were harvested from 29 individuals (21 men, 8 women; mean age: 46 ± 12) who underwent repair of an Achilles tendon tear tear, and from 11 male patients who died of cardiovascular events (mean age: 61). Three pieces of tendon were harvested: at the rupture site, 4 cm proximal to the site of rupture, 1 cm proximal to the insertion of the Achilles tendon on the calcaneum. Slides were assessed using a semiquantitative grading scale assessing fiber structure and arrangement, rounding of the nuclei, regional variations in cellularity, increased vascularity, decreased collagen stainability, and hyalinization. Intra-observer reliability of the subscore readings was calculated. The pathological features were significantly more pronounced in the samples taken from the site of rupture than in the samples taken proximally and distal to it (0.008 < P < 0.01). There were no significant differences in the mean pathologic sum-scores in the samples taken proximally and distal to the site of rupture. Unruptured Achilles tendons, even at an advanced age, and ruptured Achilles tendons are clearly part of two distinct populations, with the latter demonstrating histopathological evidence of failed healing response even in areas macroscopically normal.

  18. Smad8/BMP2-engineered mesenchymal stem cells induce accelerated recovery of the biomechanical properties of the Achilles tendon.

    PubMed

    Pelled, Gadi; Snedeker, Jess G; Ben-Arav, Ayelet; Rigozzi, Samuela; Zilberman, Yoram; Kimelman-Bleich, Nadav; Gazit, Zulma; Müller, Ralph; Gazit, Dan

    2012-12-01

    Tendon tissue regeneration is an important goal for orthopedic medicine. We hypothesized that implantation of Smad8/BMP2-engineered MSCs in a full-thickness defect of the Achilles tendon (AT) would induce regeneration of tissue with improved biomechanical properties. A 2 mm defect was created in the distal region of murine ATs. The injured tendons were then sutured together or given implants of genetically engineered MSCs (GE group), non-engineered MSCs (CH3 group), or fibrin gel containing no cells (FG group). Three weeks later the mice were killed, and their healing tendons were excised and processed for histological or biomechanical analysis. A biomechanical analysis showed that tendons that received implants of genetically engineered MSCs had the highest effective stiffness (>70% greater than natural healing, p < 0.001) and elastic modulus. There were no significant differences in either ultimate load or maximum stress among the treatment groups. Histological analysis revealed a tendon-like structure with elongated cells mainly in the GE group. ATs that had been implanted with Smad8/BMP2-engineered stem cells displayed a better material distribution and functional recovery than control groups. While additional study is required to determine long-term effects of GE MSCs on tendon healing, we conclude that genetically engineered MSCs may be a promising therapeutic tool for accelerating short-term functional recovery in the treatment of tendon injuries. Copyright © 2012 Orthopaedic Research Society.

  19. Effectiveness of xenogenous-based bovine-derived platelet gel embedded within a three-dimensional collagen implant on the healing and regeneration of the Achilles tendon defect in rabbits

    PubMed Central

    Moshiri, Ali; Oryan, Ahmad; Meimandi-Parizi, Abdolhamid; Koohi-Hosseinabadi, Omid

    2014-01-01

    Background and objective: Tissue engineering is an option in reconstructing large tendon defects and managing their healing and regeneration. We designed and produced a novel xenogeneic-based bovine platelet, embedded it within a tissue-engineered collagen implant (CI) and applied it in an experimentally induced large tendon defect model in rabbits to test whether bovine platelets could stimulate tendon healing and regeneration in vivo. Methods: One hundred twenty rabbits were randomly divided into two experimental and pilot groups. In all the animals, the left Achilles tendon was surgically excised and the tendon edges were aligned by Kessler suture. Each group was then divided into three groups of control (no implant), treated with CI and treated with collagen-platelet implant. The pilot groups were euthanized at 10, 15, 30 and 40 days post-injury (DPI), and their gross and histologic characteristics were evaluated to study host–graft interaction mechanism. To study the tendon healing and its outcome, the experimental animals were tested during the experiment using hematologic, ultrasonographic and various methods of clinical examinations and then euthanized at 60 DPI and their tendons were evaluated by gross pathologic, histopathologic, scanning electron microscopic, biophysical and biochemical methods. Results: Bovine platelets embedded within a CI increased inflammation at short term while it increased the rate of implant absorption and matrix replacement compared with the controls and CI alone. Treatment also significantly increased diameter, density, amount, alignment and differentiation of the collagen fibrils and fibers and approximated the water uptake and delivery behavior of the healing tendons to normal contralaterals (p < 0.05). Treatment also improved echogenicity and homogenicity of the tendons and reduced peritendinous adhesion, muscle fibrosis and atrophy, and therefore, it improved the clinical scores and physical activity related to the injured limb when compared with the controls (p < 0.05). Conclusion: The bovine platelet gel embedded within the tissue-engineered CI was effective in healing, modeling and remodeling of the Achilles tendon in rabbit. This strategy may be a valuable option in the clinical setting. PMID:24840092

  20. Inducement of semitendinosus tendon regeneration to the pes anserinus after its harvest for anterior cruciate ligament reconstruction-A new inducer grafting technique

    PubMed Central

    2012-01-01

    Purpose To investigate the usefulness of the “inducer grafting” technique for regeneration of the semitendinosus (ST) tendon after its harvest for anterior cruciate ligament (ACL) reconstruction. Methods Twenty knees of 20 patients (mean age at the time of surgery, 23.1 years) underwent ACL reconstruction with a double bundle autograft using the ST tendon (7 patients) and the ST + the gracilis (G) tendons (13 patients). “Inducer grafting” technique After harvesting the ST tendon, a passing pin with a loop thread is inserted along with the tendon stripper. The passing pin is pulled out from the medial thigh and the loop thread retained. As an inducer graft, the ST tendon branch is used. After the ACL graft has been secured, the inducer graft is sutured to the pes anserinus and the proximal end passed through by pulling the thread out. Then the inducer graft is placed within the tendon canal. The mean follow-up period was 15 months. The presence and morphology of the regenerated ST tendon were examined by MRI. And the isometric hamstring strength was examined at 45°, 90° and 120° of knee flexion. Results One month after the operation in all the patients, MRI demonstrated a low-intensity structure at the anatomical location of the ST, at the level of the superior pole of the patella and the joint line, apparently representing the regenerated ST tendon. Four months after the operation, the distal portion of the regenerated ST tendon had reached the pes anserinus in all patients. Twelve months after the operation, the regenerated ST tendon was hypertrophic in 19 of the 20 patients (95%). The isometric knee flexion torque of the ACL-reconstructed limb was significantly lower at 90° and 120° compared with the contralateral limb. Conclusion These results suggest that the “inducer grafting” technique is able to improve the regeneration rate of the harvested ST tendon and promote hypertrophy of the regenerated ST tendon, extending all the way to the pes anserinus. However, this technique couldn’t improve the deficits in knee flexion torque after ACL reconstruction. PMID:22607724

  1. The Biomechanical and Histologic Effects of Platelet-Rich Plasma on Rat Rotator Cuff Repairs

    PubMed Central

    Beck, Jennifer; Evans, Douglas; Tonino, Pietro M.; Yong, Sherri; Callaci, John J.

    2013-01-01

    Background Rotator cuff tears are common injuries that are often treated with surgical repair. Because of the high concentration of growth factors within platelets, platelet-rich plasma (PRP) has the potential to enhance healing in rotator cuff repairs. Hypothesis Platelet-rich plasma would alter the biomechanical and histologic properties of rotator cuff repair during an acute injury response. Study Design Controlled laboratory study. Methods Platelet-rich plasma was produced from inbred donor rats. A tendon-from-bone supraspinatus tear was created surgically and an immediate transosseous repair performed. The control group underwent repair only. The PRP group underwent a repair with PRP augmentation. Rats in each group were sacrificed at 7, 14, and 21 days. The surgically repaired tendons underwent biomechanical testing, including failure load, stiffness, failure strain, and stress relaxation characteristics. Histological analysis evaluated the cellular characteristics of the repair tissue. Results At 7- and 21-day periods, augmentation with PRP showed statistically significant effects on the biomechanical properties of the repaired rat supraspinatus tear, but failure load was not increased at the 7-, 14-, or 21-day periods (P = .688, .209, and .477, respectively). The control group had significantly higher stiffness at 21 days (P = .006). The control group had higher failure strain at 7 days (P = .02), whereas the PRP group had higher failure strain at 21 days (P = .008). Histologically, the PRP group showed increased fibroblastic response and vascular proliferation at each time point. At 21 days, the collagen fibers in the PRP group were oriented in a more linear fashion toward the tendon footprint. Conclusion In this controlled, rat model study, PRP altered the tissue properties of the supraspinatus tendon without affecting the construct’s failure load. Clinical Relevance The decreased tendon tissue stiffness acutely and failure to enhance tendon-to-bone healing of repairs should be considered before augmenting rotator cuff repairs with PRP. Further studies will be necessary to determine the role of PRP in clinical practice. PMID:22822177

  2. Multiscale regression modeling in mouse supraspinatus tendons reveals that dynamic processes act as mediators in structure-function relationships.

    PubMed

    Connizzo, Brianne K; Adams, Sheila M; Adams, Thomas H; Jawad, Abbas F; Birk, David E; Soslowsky, Louis J

    2016-06-14

    Recent advances in technology have allowed for the measurement of dynamic processes (re-alignment, crimp, deformation, sliding), but only a limited number of studies have investigated their relationship with mechanical properties. The overall objective of this study was to investigate the role of composition, structure, and the dynamic response to load in predicting tendon mechanical properties in a multi-level fashion mimicking native hierarchical collagen structure. Multiple linear regression models were investigated to determine the relationships between composition/structure, dynamic processes, and mechanical properties. Mediation was then used to determine if dynamic processes mediated structure-function relationships. Dynamic processes were strong predictors of mechanical properties. These predictions were location-dependent, with the insertion site utilizing all four dynamic responses and the midsubstance responding primarily with fibril deformation and sliding. In addition, dynamic processes were moderately predicted by composition and structure in a regionally-dependent manner. Finally, dynamic processes were partial mediators of the relationship between composition/structure and mechanical function, and results suggested that mediation is likely shared between multiple dynamic processes. In conclusion, the mechanical properties at the midsubstance of the tendon are controlled primarily by fibril structure and this region responds to load via fibril deformation and sliding. Conversely, the mechanical function at the insertion site is controlled by many other important parameters and the region responds to load via all four dynamic mechanisms. Overall, this study presents a strong foundation on which to design future experimental and modeling efforts in order to fully understand the complex structure-function relationships present in tendon. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. The enthesis organ concept and its relevance to the spondyloarthropathies.

    PubMed

    Benjamin, Michael; McGonagle, Dennis

    2009-01-01

    A characteristic feature of the spondyloarthropathies is inflammation at tendon or ligament attachment sites. This has traditionally been viewed as a focal abnormality, even though the inflammatory reaction intrinsic to enthesitis may be quite extensive. We argue that the diffuse nature of the pathology is best understood in the context of an 'enthesis organ concept'. This highlights the fact that stress concentration at an insertion site involves not only the enthesis itself, but neighbouring tissues as well. The archetypal enthesis organ is that of the Achilles tendon where intermittent contact between tendon and bone immediately proximal to the enthesis leads to the formation of fibrocartilages on the deep surface of the tendon and on the opposing calcaneal tuberosity, but similar functional modifications are widespread throughout the skeleton. Many entheses have bursae and fat near the insertion site and both of these serve to promote frictionless movement. Collectively, the fibrocartilages, bursa, fat pad and the enthesis itself constitute the enthesis organ. However, it also includes both the immediately adjacent trabecular bone networks and in some cases deep fascia. The concept of a synovio-entheseal complex (SEC) and of a 'functional enthesis' are complimentary to that of an enthesis organ and also have important implications for understanding spondyloarthropathy. The SEC concept emphasizes the interdependence between synovial membrane and entheses within enthesis organs. It draws attention to the fact that one component (the enthesis) is prone to microdamage and the other (the synovium) to inflammation. If an enthesis is damaged, any ensuing inflammatory reaction is likely to occur in the synovium. The concept of a 'functional enthesis' serves to emphasise anatomical, biomechanical and pathological features that are shared between true fibrocartilaginous entheses and regions proximal to the attachment sites themselves where tendons or ligaments wrap around bony pulleys. Such'wrap-around regions' are well documented sites of pathology in SpA-for tenosynovitis is a recognized feature. Stress concentration at the enthesis itself is dissipated at many sites by fibrous connections between one tendon or ligament and another, close to the insertion site. At a microscopic level, enthesis fibrocartilage is of paramount importance in ensuring that fibre bending of the tendon or ligament is not focused at the hard tissue interface. Normal enthesis organs are avascular in their fibrocartilaginous regions, but tissue microdamage to entheses is common and appears to be associated with tissue repair responses and vessel ingrowth. This makes the enthesis organ a site where adjuvant molecules derived from bacteria may be preferentially deposited. This microdamage and propensity for bacterial molecule deposition in the context of genetic factors such as HLA-B27 appears to lead to the characteristic inflammatory changes of AS. Understanding the enthesis organ concept helps to explain synovitis and osteitis in spondyloarthropathy. An appreciation of the complex anatomy of 'articular enthesis organs' (e.g., that associated with the distal interphalangeal joints) is helpful in understanding disease patterns in psoriatic arthritis. In this chapter, we review the extent and types ofenthesis organs and show how a patho-anatomic appreciation of these structures leads to a new platform for understanding the pathogenesis of SpA.

  4. Ultrasonography of the distal limbs in Nellore and Girolando calves 8 to 12 months of age

    PubMed Central

    2014-01-01

    Background Ultrasonography can be used anywhere and allows rapid, noninvasive differentiation of soft tissue structures of the musculoskeletal system. The objectives of this study were to describe the ultrasonographic appearance of the structures of the metacarpo-/metatarsophalangeal and the interphalangeal joints, the appearance of the growth plates of the distal metacarpus/metatarsus and of the proximal phalanx and to measure the cross-sectional dimensions of the DDFT and SDFT in Nellore and Girolando calves eight to 12 months of age. Results In the longitudinal dorsal view the common digital extensor tendon and the digital extensor tendon were depicted as echogenic parallel fiber bundles located directly under the skin. The joint spaces appeared as anechoic interruptions of the hyperechogenic bone surfaces. The normal amount of synovial fluid could not be depicted. The growth plates were seen as anechoic interruptions of the bone surface proximal and distal to the fetlock joint space. In transverse sonograms of the distal palmar/plantar regions, the flexor tendons and branchs of the suspensory ligament were imaged as echogenic structures. The lumen of the digital flexor tendon sheath could not be imaged in these normal cattle. The thin digital distal annular ligament and the reversal of positions of the DDFT and SDFT could be appreciated. No significant differences were found between the cross-sectional measurements of the DDFT and the SDFT from Nellore and Girolando in any age, thoracic/pelvic limbs, right/left sides and lateral/medial digits. Conclusions The results of this study establish important ultrasonographic reference data of the normal structures of the distal limbs and the normal dimensions of the flexor tendons in Nellore and Girolando calves for use in clinical practice. PMID:24774582

  5. Fascicles from energy-storing tendons show an age-specific response to cyclic fatigue loading

    PubMed Central

    Thorpe, Chavaunne T.; Riley, Graham P.; Birch, Helen L.; Clegg, Peter D.; Screen, Hazel R. C.

    2014-01-01

    Some tendons, such as the human Achilles and equine superficial digital flexor tendon (SDFT), act as energy stores, stretching and recoiling to increase efficiency during locomotion. Our previous observations of rotation in response to applied strain in SDFT fascicles suggest a helical structure, which may provide energy-storing tendons with a greater ability to extend and recoil efficiently. Despite this specialization, energy-storing tendons are prone to age-related tendinopathy. The aim of this study was to assess the effect of cyclic fatigue loading (FL) on the microstructural strain response of SDFT fascicles from young and old horses. The data demonstrate two independent age-related mechanisms of fatigue failure; in young horses, FL caused low levels of matrix damage and decreased rotation. This suggests that loading causes alterations to the helix substructure, which may reduce their ability to recoil and recover. By contrast, fascicles from old horses, in which the helix is already compromised, showed greater evidence of matrix damage and suffer increased fibre sliding after FL, which may partially explain the age-related increase in tendinopathy. Elucidation of helix structure and the precise alterations occurring owing to both ageing and FL will help to develop appropriate preventative and repair strategies for tendinopathy. PMID:24402919

  6. Returning to Overuse Activity Following a Supraspinatus and Infraspinatus Tear Leads to Joint Damage in a Rat Model

    PubMed Central

    Reuther, Katherine E.; Thomas, Stephen J.; Evans, Elisabeth F.; Tucker, Jennica J.; Sarver, Joseph J.; Ilkhani-Pour, Sarah; Gray, Chancellor F.; Voleti, Pramod; Glaser, David L.; Soslowsky, Louis J.

    2013-01-01

    Large rotator cuff tears (supraspinatus and infraspinatus) are common in patients that perform overhead activities (laborers, athletes). In addition, following large cuff tears, these patients commonly attempt to return to pre-injury activity levels. However, there is a limited understanding of the damaging effects on the uninjured joint tissues when doing so. Therefore, the objective of this study was to investigate the effect of returning to overuse activity following a supraspinatus and infraspinatus tear on shoulder function and the structural and biological properties of the intact tendons and glenoid cartilage. Forty rats underwent four weeks of overuse followed by detachment of the supraspinatus and infraspinatus tendons and were then randomized into two groups: return to overuse or cage activity. Ambulatory measurements were performed over time and structural and biologic properties of the adjacent tendons and cartilage were evaluated. Results demonstrated that animals returning to overuse activity did not have altered shoulder function but despite this, did have altered cartilage and tendon properties. These mechanical changes corresponded to altered transcriptional regulation of chondrogenic genes within cartilage and tendon. This study helps define the mechanical and biologic mechanisms leading to joint damage and provides a framework for treating active cuff tear patients. PMID:23764174

  7. Revisiting physical examination: Abadie's sign and Achilles intratendinous changes in subjects with diabetes.

    PubMed

    Abate, Michele; Schiavone, Cosima; Salini, Vincenzo; Andia, Isabel

    2014-01-01

    The aim of this study was to evaluate whether or not the positivity of Abadie's sign could be an indicator of asymptomatic Achilles intratendinous changes. A total of 18 patients (36 tendons) suffering from diabetes, with at least 1 Achilles tendon positive to Abadie's sign, were compared to matched subjects with diabetes bilaterally negative to Abadie's sign. Anthropometric measures and the Toronto Clinical Neuropathy Score were registered. Echotexture was evaluated and degenerative features classified as absent, mild, moderate and severe. The frequencies of structural abnormalities, according to both Abadie's sign and the Toronto Clinical Neuropathy Score, were determined. In the first group 26 out of 36 tendons (72.2%) showed positive Abadie's sign and a significantly higher frequency of moderate and severe (65.3%) structural abnormalities compared to Achilles tendons with negative sign (4.3%; p < 0.0001). This frequency was similar to that observed in the subjects with the highest Toronto Clinical Neuropathy Score (64.2%). This study showed that Abadie's sign was a useful tool for assisting in the diagnosis of asymptomatic Achilles intratendinous changes, which, when detected early, could help prevent unexpected tendon rupture. The concordance between Abadie's sign and Achilles sonographic abnormalities needs to be evaluated in a larger sample to consider it useful for practical purposes. © 2013 S. Karger AG, Basel.

  8. The Incidence of Acute Traumatic Tendon Injuries in the Hand and Wrist: A 10-Year Population-based Study

    PubMed Central

    de Jong, Johanna P.; Nguyen, Jesse T.; Sonnema, Anne J. M.; Nguyen, Emily C.; Amadio, Peter C.

    2014-01-01

    Background Acute traumatic tendon injuries of the hand and wrist are commonly encountered in the emergency department. Despite the frequency, few studies have examined the true incidence of acute traumatic tendon injuries in the hand and wrist or compared the incidences of both extensor and flexor tendon injuries. Methods We performed a retrospective population-based cohort study of all acute traumatic tendon injuries of the hand and wrist in a mixed urban and rural Midwest county in the United States between 2001-2010. A regional epidemiologic database and medical codes were used to identify index cases. Epidemiologic information including occupation, year of injury, mechanism of injury and the injured tendon and zone were recorded. Results During the 10-year study period there was an incidence rate of 33.2 injuries per 100,000 person-years. There was a decreasing rate of injury during the study period. Highest incidence of injury occurred at 20-29 years of age. There was significant association between injury rate and age, and males had a higher incidence than females. The majority of cases involved a single tendon, with extensor tendon injuries occurring more frequently than flexor tendons. Typically, extensor tendon injuries involved zone three of the index finger, while flexor tendons involved zone two of the index finger. Work-related injuries accounted for 24.9% of acute traumatic tendon injuries. The occupations of work-related injuries were assigned to major groups defined by the 2010 Standard Occupational Classification structure. After assigning these patients' occupations to respective major groups, the most common groups work-related injuries occurred in construction and extraction occupations (44.2%), food preparation and serving related occupations (14.4%), and transportation and material moving occupations (12.5%). Conclusions Epidemiology data enhances our knowledge of injury patterns and may play a role in the prevention and treatment of future injuries, with an end result of reducing lost work time and economic burden. PMID:24900902

  9. Interactions between tenocytes and monosodium urate monohydrate crystals: implications for tendon involvement in gout.

    PubMed

    Chhana, Ashika; Callon, Karen E; Dray, Michael; Pool, Bregina; Naot, Dorit; Gamble, Greg D; Coleman, Brendan; McCarthy, Geraldine; McQueen, Fiona M; Cornish, Jillian; Dalbeth, Nicola

    2014-09-01

    Advanced imaging studies have demonstrated that urate deposition in periarticular structures, such as tendons, is common in gout. The aim of this study was to investigate the effects of monosodium urate monohydrate (MSU) crystals on tenocyte viability and function. The histological appearance of tendons in joints affected by advanced gout was examined using light microscopy. In vitro, colorimetric assays and flow cytometry were used to assess cell viability in primary rat and primary human tenocytes cultured with MSU crystals. Real-time PCR was used to determine changes in the relative mRNA expression levels of tendon-related genes, and Sirius red staining was used to measure changes in collagen deposition in primary rat tenocytes. In joint samples from patients with gout, MSU crystals were identified within the tendon, adjacent to and invading into tendon, and at the enthesis. MSU crystals reduced tenocyte viability in a dose-dependent manner. MSU crystals decreased the mRNA expression of tendon collagens, matrix proteins and degradative enzymes and reduced collagen protein deposition by tenocytes. These data indicate that MSU crystals directly interact with tenocytes to reduce cell viability and function. These interactions may contribute to tendon damage in people with advanced gout. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  10. Viscoelastic properties of healthy achilles tendon are independent of isometric plantar flexion strength and cross-sectional area.

    PubMed

    Suydam, Stephen M; Soulas, Elizabeth M; Elliott, Dawn M; Silbernagel, Karin Gravare; Buchanan, Thomas S; Cortes, Daniel H

    2015-06-01

    Changes in tendon viscoelastic properties are observed after injuries and during healing as a product of altered composition and structure. Continuous Shear Wave Elastography is a new technique measuring viscoelastic properties of soft tissues using external shear waves. Tendon has not been studied with this technique, therefore, the aims of this study were to establish the range of shear and viscosity moduli in healthy Achilles tendons, determine bilateral differences of these parameters and explore correlations of viscoelasticity to plantar flexion strength and tendon area. Continuous Shear Wave Elastography was performed over the free portion of both Achilles tendons from 29 subjects. Isometric plantar flexion strength and cross sectional area were measured. The average shear and viscous moduli was 83.2 kPa and 141.0 Pa-s, respectively. No correlations existed between the shear or viscous modulus and area or strength. This indicates that viscoelastic properties can be considered novel, independent biomarkers. The shear and viscosity moduli were bilaterally equivalent (p = 0.013, 0.017) which allows determining pathologies through side-to-side deviations. The average bilateral coefficient of variation was 7.2% and 9.4% for shear and viscosity modulus, respectively. The viscoelastic properties of the Achilles tendon may provide an unbiased, non-subjective rating system of tendon recovery and optimizing treatment strategies. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  11. Viscoelastic Properties of Healthy Achilles Tendon are Independent of Isometric Plantar Flexion Strength and Cross-Sectional Area

    PubMed Central

    Suydam, Stephen M.; Soulas, Elizabeth M.; Elliott, Dawn M.; Silbernagel, Karin Gravare; Buchanan, Thomas S.; Cortes, Daniel H.

    2015-01-01

    Changes in tendon viscoelastic properties are observed after injuries and during healing as a product of altered composition and structure. Continuous Shear Wave Elastography is a new technique measuring viscoelastic properties of soft tissues using external shear waves. Tendon has not been studied with this technique, therefore, the aims of this study were to establish the range of shear and viscosity moduli in healthy Achilles tendons, determine bilateral differences of these parameters and explore correlations of viscoelasticity to plantar flexion strength and tendon area. Continuous Shear Wave Elastography was performed over the free portion of both Achilles tendons from 29 subjects. Isometric plantar flexion strength and cross sectional area were measured. The average shear and viscous moduli was 83.2kPa and 141.0Pa-s, respectively. No correlations existed between the shear or viscous modulus and area or strength. This indicates that viscoelastic properties can be considered novel, independent biomarkers. The shear and viscosity moduli were bilaterally equivalent (p=0.013,0.017) which allows determining pathologies through side-to-side deviations. The average bilateral coefficient of variation was 7.2% and 9.4% for shear and viscosity modulus, respectively. The viscoelastic properties of the Achilles tendon may provide an unbiased, non-subjective rating system of tendon recovery and optimizing treatment strategies. PMID:25882209

  12. Role of tissue engineered collagen based tridimensional implant on the healing response of the experimentally induced large Achilles tendon defect model in rabbits: a long term study with high clinical relevance

    PubMed Central

    2013-01-01

    Background Tendon injury is one of the orthopedic conditions poses with a significant clinical challenge to both the surgeons and patients. The major limitations to manage these injuries are poor healing response and development of peritendinous adhesions in the injured area. This study investigated the effectiveness of a novel collagen implant on tendon healing in rabbits. Results Seventy five mature White New-Zealand rabbits were divided into treated (n = 55) and control (n = 20) groups. The left Achilles tendon was completely transected and 2 cm excised. The defects of the treated animals were filled with collagen implants and repaired with sutures, but in control rabbits the defects were sutured similarly but the gap was left untreated. Changes in the injured and normal contralateral tendons were assessed weekly by measuring the diameter, temperature and bioelectrical characteristics of the injured area. Clinical examination was done and scored. Among the treated animals, small pilot groups were euthanized at 5, 10, 15, 20, 30, 40 and 60 (n = 5 at each time interval) and the remainder (n = 20) and the control animals at 120 days post injury (DPI). The lesions of all animals were examined at macroscopic and microscopic levels and the dry matter content, water delivery and water uptake characteristics of the lesions and normal contralateral tendons of both groups were analyzed at 120 DPI. No sign of rejection was seen in the treated lesions. The collagen implant was invaded by the inflammatory cells at the inflammatory phase, followed by fibroplasia phase in which remnant of the collagen implant were still present while no inflammatory reaction could be seen in the lesions. However, the collagen implant was completely absorbed in the remodeling phase and the newly regenerated tendinous tissue filled the gap. Compared to the controls, the treated lesions showed improved tissue alignment and less peritendinous adhesion, muscle atrophy and fibrosis. They also showed significantly better clinical scoring, indices for water uptake and water absorption, and bioelectrical characteristics than the controls. Conclusion This novel collagen implant was biodegradable, biocompatible and possibly could be considered as a substitute for auto and allografts in clinical practice in near future. PMID:23672303

  13. Muscle-Tendon-Enthesis Unit.

    PubMed

    Tadros, Anthony S; Huang, Brady K; Pathria, Mini N

    2018-07-01

    Injuries to the muscle-tendon-enthesis unit are common and a significant source of pain and loss of function. This article focuses on the important anatomical and biomechanical considerations for each component of the muscle-tendon-enthesis unit. We review normal and pathologic conditions affecting this unit, illustrating the imaging appearance of common disorders on magnetic resonance imaging and ultrasound. Knowledge of the anatomy and biomechanics of these structures is crucial for the radiologist to make accurate diagnoses and provide clinically relevant assessments. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  14. Achilles and patellar tendinopathy display opposite changes in elastic properties: A shear wave elastography study.

    PubMed

    Coombes, B K; Tucker, K; Vicenzino, B; Vuvan, V; Mellor, R; Heales, L; Nordez, A; Hug, F

    2018-03-01

    To compare tendon elastic and structural properties of healthy individuals with those with Achilles or patellar tendinopathy. Sixty-seven participants (22 Achilles tendinopathy, 17 patellar tendinopathy, and 28 healthy controls) were recruited between March 2015 and March 2016. Shear wave velocity (SWV), an index of tissue elastic modulus, and tendon thickness were measured bilaterally at mid-tendon and insertional regions of Achilles and patellar tendons by an examiner blinded to group. Analysis of covariance, adjusted for age, body mass index, and sex was used to compare differences in tendon thickness and SWV between the two tendinopathy groups (relative to controls) and regions. Tendon thickness was included as a covariate for analysis of SWV. Compared to controls, participants with Achilles tendinopathy had lower SWV at the distal insertion (Mean difference MD; 95% CI: -1.56; -2.49 to -0.62 m/s; P < .001) and greater thickness at the mid-tendon (MD 0.19; 0.05-0.33 cm; P = .007). Compared to controls, participants with patellar tendinopathy had higher SWV at both regions (MD 1.25; 0.40-2.10 m/s; P = .005) and greater thickness proximally (MD 0.17; 0.06-0.29 cm; P = .003). Compared to controls, participants with Achilles and patellar tendinopathy displayed lower Achilles tendon elastic modulus and higher patellar tendon elastic modulus, respectively. More research is needed to explore whether maturation, aging, or chronic load underlie these findings and whether current management programs for Achilles and patellar tendinopathy need to be tailored to the tendon. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Sustained-release of naproxen sodium from electrospun-aligned PLLA-PCL scaffolds.

    PubMed

    Lui, Yuan Siang; Lewis, Mark P; Loo, Say Chye Joachim

    2017-04-01

    Spontaneous tendon healing may result in reduced tissue functionality. In view of this, tissue engineering (TE) emerges as a promising approach in promoting proper tendon regeneration. However, unfavourable post-surgical adhesion formations restrict adequate tendon healing through the TE approach. Naproxen sodium (NPS), a non-steroidal anti-inflammatory drug (NSAID), has been demonstrated to prevent adhesions by inhibiting the inflammatory response. Therefore, in this study, various factors, such as polymer composition, i.e. different poly-l-lactic acid (PLLA):polycaprolactone (PCL) ratios, and percentage of water:hexafluoroisopropanol (HFIP; as co-solvent) ratios, were investigated to understand how these can influence the release of NPS from electrospun scaffolds. By adjusting the amount of water as the co-solvent, NPS could be released sustainably for as long as 2 weeks. Scaffold breaking strength was also enhanced with the addition of water as the co-solvent. This NPS-loaded scaffold showed no significant cytotoxicity, and L929 murine fibroblasts cultured on the scaffolds were able to proliferate and align along the fibre orientation. These scaffolds with desirable tendon TE characteristics would be promising candidates in achieving better tendon regeneration in vivo. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  16. Cell therapy for tendinitis, experimental and clinical report.

    PubMed

    Lacitignola, L; Crovace, A; Rossi, G; Francioso, E

    2008-09-01

    To compare cultured bone marrow mesenchymal cells (cBMSC), bone marrow mononucleated cells (BMMNCs), and placebo to repair collagenase-induced tissue damage in an equine model of experimental tendonitis, 6 Standardbred horses with no signs of previous SDF tendon injury have been recruited. Three weeks after collagenase treatment an average of either 5.5 x 10(6) cBMSCs or 122.3 x 10(6) BMMNCs, saline solution (placebo) or fibrin glue were injected intralesionally in random order. Horses were stall rested for 21 weeks, and tendon ultrasound scans performed before and during this period. Horses were euthanized and tendons harvested for histology and immunohistochemistry. Data observed in this study showed effectiveness of cBMSC and BMMNC in regenerating tendon tissue after collagenase -induced tendonitis. Both cBMSC and BMMNC transplantation resulted in qualitatively similar regeneration of tendon extracellular matrix in terms of type I/III collagen ratio, fiber orientation, and COMP expression. After this favourable results, 20 horses were recruited referred for spontaneous lesions of the flexor tendons or the suspensory ligament. Horses were treated with autologous graft of BMMNCs.After treatment the. the exercise program allowed was 8 weeks stall rest, 4 weeks hand walking, 4 weeks trotting, 4 weeks of gradually raising of exercise level then horses were gone back to race. US characteristics of lesions started to improve at T3. CSA-l, FPS and TLS were better in all patients, with an appreciable filling of lesions indicated by a decreasing of CSA-l and increasing of TLS. When horses started the exercise program T8 tendon architecture improved, demonstrated by their longitudinal alignment and length. At T6, and persistently in later follow-up, no lameness was evident by clinical examination. At time of writing 12 patients (60%) were go back to races, while other 8 (40%) are under controlled exercise program. Re-injury rate was assessed at 25%. All the owners judged good to excellent the outcome in term of athletic success.

  17. Tendinous tissue properties after short- and long-term functional overload: Differences between controls, 12 weeks and 4 years of resistance training.

    PubMed

    Massey, G J; Balshaw, T G; Maden-Wilkinson, T M; Folland, J P

    2018-04-01

    The potential for tendinous tissues to adapt to functional overload, especially after several years of exposure to heavy-resistance training, is largely unexplored. This study compared the morphological and mechanical characteristics of the patellar tendon and knee extensor tendon-aponeurosis complex between young men exposed to long-term (4 years; n = 16), short-term (12 weeks; n = 15) and no (untrained controls; n = 39) functional overload in the form of heavy-resistance training. Patellar tendon cross-sectional area, vastus lateralis aponeurosis area and quadriceps femoris volume, plus patellar tendon stiffness and Young's modulus, and tendon-aponeurosis complex stiffness, were quantified with MRI, dynamometry and ultrasonography. As expected, long-term trained had greater muscle strength and volume (+58% and +56% vs untrained, both P < .001), as well as a greater aponeurosis area (+17% vs untrained, P < .01), but tendon cross-sectional area (mean and regional) was not different between groups. Only long-term trained had reduced patellar tendon elongation/strain over the whole force/stress range, whilst both short-term and long-term overload groups had similarly greater stiffness/Young's modulus at high force/stress (short-term +25/22%, and long-term +17/23% vs untrained; all P < .05). Tendon-aponeurosis complex stiffness was not different between groups (ANOVA, P = .149). Despite large differences in muscle strength and size, years of resistance training did not induce tendon hypertrophy. Both short-term and long-term overload demonstrated similar increases in high-force mechanical and material stiffness, but reduced elongation/strain over the whole force/stress range occurred only after years of overload, indicating a force/strain specific time-course to these adaptations. © 2017 Scandinavian Physiological Society. Published by John Wiley & Sons Ltd.

  18. The development and morphogenesis of the tendon-to-bone insertion What development can teach us about healing

    PubMed Central

    Thomopoulos, Stavros; Genin, Guy M.; Galatz, Leesa M.

    2013-01-01

    The attachment of dissimilar materials is a major challenge because of the high levels of stress that develop at such interfaces. An effective solution to this problem develops at the attachment of tendon (a compliant “soft tissue”) to bone (a stiff “hard tissue”). This tissue, the “enthesis”, transitions from tendon to bone through gradations in structure, composition, and mechanical properties. These gradations are not regenerated during tendon-to-bone healing, leading to a high incidence of failure after surgical repair. Understanding the development of the enthesis may allow scientists to develop treatments that regenerate the natural tendon-to-bone insertion. Recent work has demonstrated that both biologic and mechanical factors drive the development and morphogenesis of the enthesis. A cascade of biologic signals similar to those seen in the growth plate promotes mineralization of cartilage on the bony end of the enthesis and the formation of fibrocartilage on the tendon end of the enthesis. Mechanical loading is also necessary for the development of the enthesis. Removal of muscle load impairs the formation of bone, fibrocartilage, and tendon at the developing enthesis. This paper reviews recent work on the development of the enthesis, with an emphasis on the roles of biologic and mechanical factors. PMID:20190378

  19. Delayed Exercise Promotes Remodeling in Sub-Rupture Fatigue Damaged Tendons

    PubMed Central

    Bell, R.; Boniello, M.R.; Gendron, N.R.; Flatow, E.L.; Andarawis-Puri, N.

    2015-01-01

    Tendinopathy is a common musculoskeletal injury whose treatment is limited by ineffective therapeutic interventions. Previously we have shown that tendons ineffectively repair early sub-rupture fatigue damage. In contrast, physiological exercise has been shown to promote remodeling of healthy tendons but its utility as a therapeutic to promote repair of fatigue damaged tendons remains unknown. Therefore, the objective of this study was to assess the utility of exercise initiated 1 and 14 days after onset of fatigue damage to promote structural repair in fatigue damaged tendons. We hypothesized that exercise initiated 14 days after fatigue loading would promote remodeling as indicated by a decrease in area of collagen matrix damage, increased procollagen I and decorin, while decreasing proteins indicative of tendinopathy. Rats engaged in 6-week exercise for 30 min/day or 60 min/day starting 1 or 14 days after fatigue loading. Initiating exercise 1-day after onset of fatigue injury led to exacerbation of matrix damage, particularly at the tendon insertion. Initiating exercise 14 days after onset of fatigue injury led to remodeling of damaged regions in the midsubstance and collagen synthesis at the insertion. Physiological exercise applied after the initial biological response to injury has dampened can potentially promote remodeling of damaged tendons. PMID:25732052

  20. MicroRNA29a regulates IL-33-mediated tissue remodelling in tendon disease

    PubMed Central

    Millar, Neal L.; Gilchrist, Derek S.; Akbar, Moeed; Reilly, James H.; Kerr, Shauna C.; Campbell, Abigail L.; Murrell, George A. C.; Liew, Foo Y.; Kurowska-Stolarska, Mariola; McInnes, Iain B.

    2015-01-01

    MicroRNA (miRNA) has the potential for cross-regulation and functional integration of discrete biological processes during complex physiological events. Utilizing the common human condition tendinopathy as a model system to explore the cross-regulation of immediate inflammation and matrix synthesis by miRNA we observed that elevated IL-33 expression is a characteristic of early tendinopathy. Using in vitro tenocyte cultures and in vivo models of tendon damage, we demonstrate that such IL-33 expression plays a pivotal role in the transition from type 1 to type 3 collagen (Col3) synthesis and thus early tendon remodelling. Both IL-33 effector function, via its decoy receptor sST2, and Col3 synthesis are regulated by miRNA29a. Downregulation of miRNA29a in human tenocytes is sufficient to induce an increase in Col3 expression. These data provide a molecular mechanism of miRNA-mediated integration of the early pathophysiologic events that facilitate tissue remodelling in human tendon after injury. PMID:25857925

  1. Implementation of a smartphone as a wireless gyroscope application for the quantification of reflex response.

    PubMed

    LeMoyne, Robert; Mastroianni, Timothy

    2014-01-01

    The patellar tendon reflex constitutes a fundamental aspect of the conventional neurological evaluation. Dysfunctional characteristics of the reflex response can augment the diagnostic acuity of a clinician for subsequent referral to more advanced medical resources. The capacity to quantify the reflex response while alleviating the growing strain on specialized medical resources is a topic of interest. The quantification of the tendon reflex response has been successfully demonstrated with considerable accuracy and consistency through using a potential energy impact pendulum attached to a reflex hammer for evoking the tendon reflex with a smartphone, such as an iPhone, application representing a wireless accelerometer platform to quantify reflex response. Another sensor integrated into the smartphone, such as an iPhone, is the gyroscope, which measures rate of angular rotation. A smartphone application enables wireless transmission through Internet connectivity of the gyroscope signal recording of the reflex response as an email attachment. The smartphone wireless gyroscope application demonstrates considerable accuracy and consistency for the quantification of the tendon reflex response.

  2. Tendon Reconstruction with Tissue Engineering Approach--A Review.

    PubMed

    Verdiyeva, Gunay; Koshy, Kiron; Glibbery, Natalia; Mann, Haroon; Seifalian, Alexander M

    2015-09-01

    Tendon injuries are a common and rising occurrence, associated with significant impairment to quality of life and financial burden to the healthcare system. Clinically, they represent an unresolved problem, due to poor natural tendon healing and the inability of current treatment strategies to restore the tendon to its native state. Tissue engineering offers a promising alternative, with the incorporation of scaffolds, cells and growth factors to support the complete regeneration of the tendon. The materials used in tendon engineering to date have provided significant advances in structural integrity and biological compatibility and in many cases the results obtained are superior to those observed in natural healing. However, grafts fail to reproduce the qualities of the pre-injured tendon and each has weaknesses subject to its constituent parts. Furthermore, many materials and cell types are being investigated concurrently, with seemingly little association or comparison between research results. In this review the properties of the most-investigated and effective components have been appraised in light of the surrounding literature, with research from early in-vitro experiments to clinical trials being discussed. Extensive comparisons have been made between scaffolds, cell types and growth factors used, listing strengths and weaknesses to provide a stable platform for future research. Promising future endeavours are also described in the field of nanocomposite material science, stem cell sources and growth factors, which may bypass weaknesses found in individual elements. The future of tendon engineering looks bright, with growing understanding in material technology, cell and growth factor application and encouraging recent advances bringing us ever closer to regenerating the native tendon.

  3. The structure of the insertions of the tendons of biceps brachii, triceps and brachialis in elderly dissecting room cadavers.

    PubMed Central

    Benjamin, M; Newell, R L; Evans, E J; Ralphs, J R; Pemberton, D J

    1992-01-01

    The terminal portions of the tendon of brachialis, and the distal tendons of biceps brachii and triceps, were compared by routine histology. All tendons came from elderly dissecting room cadavers. There were pronounced quantitative differences between the 3 tendons in (1) the thickness of the attachment-zone fibrocartilage, (2) the thickness of cortical calcified tissue, and (3) the percentage of bone to marrow. There was significantly more uncalcified fibrocartilage at the attachment of biceps than at the other sites, reflecting greater range of movement of the tendon at this site. The thickness of cortical calcified tissue and the percentage of bone to marrow were significantly greater at the attachment of brachialis than either biceps or triceps. The large quantities of bone at the attachment of brachialis may be related more to the importance of the coronoid process in buttressing the elbow joint than to any special requirement for large amounts of calcified tissue at the tendon attachment. Near its attachment zone, the biceps tendon splits into superficial and deep laminae that are distinct from the macroscopic subdivision of this tendon. It is suggested that the lamination may facilitate the movements of pronation and supination. In support of this, the deep portion of the superficial lamina contained fibrocartilage where it rubbed against the attachment-zone of the deep lamina. In one body, the fibrocartilage of the biceps attachment-zone was subject to degenerative changes, including cell clumping and matrix fissuring. Images Fig. 2 Fig. 3 PMID:1506288

  4. Magnetic resonance anatomy of the superior part of the rotator cuff in normal shoulders, assessment and practical implication.

    PubMed

    Michelin, Paul; Trintignac, Adrien; Dacher, Jean Nicolas; Carvalhana, Gilbert; Lefebvre, Valentin; Duparc, Fabrice

    2014-12-01

    The superior part of the rotator cuff consists of the anterior (SSa) and posterior (SSp) parts of the supraspinatus tendon, the infraspinatus (IS) tendon plus the articular capsule. An overlap of the distal SSp tendon by the anterior part of the IS one has been anatomically demonstrated; the insertion area of the IS is more anterior than currently believed. The aim of our study was to assess this complex architecture through standard MRI scans. Twenty-five healthy volunteers underwent a shoulder MRI. Three planes T2 fat saturation sequences were read in consensus by two radiologists. The SSa, the SSp, the IS tendons and the articular capsule were assessed for visibility. The patterns of demarcation of each structure from adjacent ones were assessed. The width and the thickness of each tendinous band were measured on sagittal images. The SSa, the SSp and the IS tendons were distinguishable in all patients. The anterior part of the IS tendon overlapped the SSp tendon to reach a quite anterior insertion into the greater tuberosity of the humerus. The SSa, the SSp and the IS tendons were 6.5-3.4, 15.1-2.8 and 26.8-2.2 mm wide and thick, respectively. MR images of the normal superior rotator cuff are consistent with latest anatomical descriptions. The distal superposition of the IS over the SSp tendon should be considered regarding the linear increased signal areas and the commonly named "partial thickness ruptures" of the superior rotator cuff as well as the fatty infiltration of the IS muscle.

  5. Greater inadvertent muscle damage in direct anterior approach when compared with the direct superior approach for total hip arthroplasty.

    PubMed

    Amanatullah, D F; Masini, M A; Roger, D J; Pagnano, M W

    2016-08-01

    We wished to quantify the extent of soft-tissue damage sustained during minimally invasive total hip arthroplasty through the direct anterior (DA) and direct superior (DS) approaches. In eight cadavers, the DA approach was performed on one side, and the DS approach on the other, a single brand of uncemented hip prosthesis was implanted by two surgeons, considered expert in their surgical approaches. Subsequent reflection of the gluteus maximus allowed the extent of muscle and tendon damage to be measured and the percentage damage to each anatomical structure to be calculated. The DA approach caused substantially greater damage to the gluteus minimus muscle and tendon when compared with the DS approach (t-test, p = 0.049 and 0.003, respectively). The tensor fascia lata and rectus femoris muscles were damaged only in the DA approach. There was no difference in the amount of damage to the gluteus medius muscle and tendon, piriformis tendon, obturator internus tendon, obturator externus tendon or quadratus femoris muscle between approaches. The posterior soft-tissue releases of the DA approach damaged the gluteus minimus muscle and tendon, piriformis tendon and obturator internus tendon. The DS approach caused less soft-tissue damage than the DA approach. However the clinical relevance is unknown. Further clinical outcome studies, radiographic evaluation of component position, gait analyses and serum biomarker levels are necessary to evaluate and corroborate the safety and efficacy of the DS approach. Cite this article: Bone Joint J 2016;98-B1036-42. ©2016 The British Editorial Society of Bone & Joint Surgery.

  6. Rotator cuff healing after continuous subacromial bupivacaine infusion: an in vivo rabbit study

    PubMed Central

    FRIEL, NICOLE A.; WANG, VINCENT M.; SLABAUGH, MARK A.; WANG, FANCHIA; CHUBINSKAYA, SUSAN; COLE, BRIAN J.

    2013-01-01

    Background The objective of this study was to evaluate the effects of continuous subacromial bupivacaine infusion on supraspinatus muscle and rotator cuff tendon healing via gross, biomechanical, and histologic analyses. Methods Thirty-three New Zealand White rabbits underwent unilateral supraspinatus transection and rotator cuff repair (RCR). Rabbits were assigned to 1 of 3 groups: (1)RCR only, (2)RCR with continuous saline infusion for 48 hours, or (3)RCR with continuous 0.25% bupivacaine with epinephrine (1:200,000) infusion for 48 hours. Rabbits were sacrificed at either 2 (for histologic assessment) or 8 weeks post-operatively (for biomechanical and histologic assessment). Results Tensile testing showed significantly higher load to failure in intact tendons compared to repaired tendons (p<0.01); however, no statistical differences were detected among RCR only, RCR Saline, and RCR Bupivacaine groups. Histologically, the enthesis of repaired tendons showed increased cellularity and disorganized collagen fibers compared to intact tendons, with no differences between treatment groups. Muscle histology demonstrated scattered degenerative muscle fibers at 2 weeks in both RCR Saline and RCR Bupivacaine, but no degeneration was noted at 8 weeks. Conclusions The healing supraspinatus tendons exposed to bupivacaine infusion showed similar histologic and biomechanical characteristics compared to untreated and saline infused RCR groups. Muscle histology showed fiber damage at 2 weeks for both the saline and bupivacaine treated groups, with no apparent disruption at 8 weeks, suggesting a recovery process. Therefore, subacromial bupivacaine infusion in this rabbit rotator cuff model does not appear to impair muscle or tendon following acute injury and repair. Level Of Evidence Basic science study PMID:22818894

  7. Leg tendon glands in male bumblebees ( Bombus terrestris): structure, secretion chemistry, and possible functions

    NASA Astrophysics Data System (ADS)

    Jarau, Stefan; Žáček, Petr; Šobotník, Jan; Vrkoslav, Vladimír; Hadravová, Romana; Coppée, Audrey; Vašíčková, Soňa; Jiroš, Pavel; Valterová, Irena

    2012-12-01

    Among the large number of exocrine glands described in bees, the tarsal glands were thought to be the source of footprint scent marks. However, recent studies showed that the compounds used for marking by stingless bees are secreted by leg tendon instead of tarsal glands. Here, we report on the structure of leg tendon glands in males of Bombus terrestris, together with a description of the chemical composition of their secretions and respective changes of both during the males' lives. The ultrastructure of leg tendon glands shows that the secretory cells are located in three independent regions, separated from each other by unmodified epidermal cells: in the femur, tibia, and basitarsus. Due to the common site of secretion release, the organ is considered a single secretory gland. The secretion of the leg tendon glands of B. terrestris males differs in its composition from those of workers and queens, in particular by (1) having larger proportions of compounds with longer chain lengths, which we identified as wax esters; and (2) by the lack of certain hydrocarbons (especially long chain dienes). Other differences consist in the distribution of double bond positions in the unsaturated hydrocarbons that are predominantly located at position 9 in males but distributed at seven to nine different positions in the female castes. Double bond positions may change chemical and physical properties of a molecule, which can be recognized by the insects and, thus, may serve to convey specific information. The function of male-specific compounds identified from their tendon glands remains elusive, but several possibilities are discussed.

  8. Achilles tendinopathy modulates force frequency characteristics of eccentric exercise.

    PubMed

    Grigg, Nicole L; Wearing, Scott C; O'Toole, John M; Smeathers, James E

    2013-03-01

    Previous research has demonstrated that ground reaction force (GRF) recorded during eccentric ankle exercise is characterized by greater power in the 8- to 12-Hz bandwidth when compared with that recorded during concentric ankle exercise. Subsequently, it was suggested that vibrations in this bandwidth may underpin the beneficial effect of eccentric loading in tendon repair. However, this observation has been made only in individuals without Achilles tendinopathy. This research compared the force frequency characteristics of eccentric and concentric exercises in individuals with and without Achilles tendinopathy. Eleven male adults with unilateral midportion Achilles tendinopathy and nine control male adults without tendinopathy participated in the research. Kinematics and GRF were recorded while the participants performed a common eccentric rehabilitation exercise protocol and a concentric equivalent. Ankle joint kinematics and the frequency power spectrum of the resultant GRF were calculated. Eccentric exercise was characterized by a significantly greater proportion of spectral power between 4.5 and 11.5 Hz when compared with concentric exercise. There were no significant differences between limbs in the force frequency characteristics of concentric exercise. Eccentric exercise, in contrast, was defined by a shift in the power spectrum of the symptomatic limb, resulting in a second spectral peak at 9 Hz, rather than 10 Hz in the control limb. Compared with healthy tendon, Achilles tendinopathy was characterized by lower frequency vibrations during eccentric rehabilitation exercises. This finding may be associated with changes in neuromuscular activation and tendon stiffness that have been shown to occur with tendinopathy and provides a possible rationale for the previous observation of a different biochemical response to eccentric exercise in healthy and injured Achilles tendons.

  9. Finite Element Analysis of Grouting Compactness Monitoring in a Post-Tensioning Tendon Duct Using Piezoceramic Transducers

    PubMed Central

    Jiang, Tianyong; Song, Gangbing

    2017-01-01

    With the development of the post-tensioning technique, prestressed concrete structures have been widely used in civil engineering. To ensure the long-term effectiveness of the prestressed tendon, the grouting quality of the tendon duct is one of the important factors. However, it is still a challenge to monitor the grouting quality of post-tensioning tendon ducts, due to the invisibility of the grouting. The authors’ previous work proposed a real-time method that employed a stress wave-based active sensing approach with piezoceramic transducers to monitor the grouting compactness of a Post-Tensioning Tendon Duct (PTTD). To further understand the piezoceramic induced stress wave propagation in the PTTD with different grouting levels, this paper develops a two-dimensional finite element model for monitoring the grouting compactness of the tendon duct with a piezoceramic transducer. A smart aggregate (SA) developed to utilize one Lead Zirconate Titanate (PZT) transducer with marble protection is installed in the center location of the tendon duct as an actuator. Two PZT patches are bonded on the bottom and top surface of the tendon duct as the sensors. The analysis results show that the finite element analysis results are in good agreement with the experimental results, which demonstrates that the finite element analysis is feasible and reliable. For the top half of the specimen, not much stress wave could be detected before the full grouting level, except for negligible signals that may propagate through the walls of the tendon duct. When the tendon duct grouting is at 100%, the stress wave propagates to the top of the specimen, and the displacements are symmetric in both left-right and top-bottom directions before the stress waves reach the boundary. The proposed two-dimensional finite element model has the potential to be implemented to simulate the stress wave propagation principle for monitoring grouting compaction of the post-tensioning tendon duct. PMID:28961173

  10. Finite Element Analysis of Grouting Compactness Monitoring in a Post-Tensioning Tendon Duct Using Piezoceramic Transducers.

    PubMed

    Jiang, Tianyong; Zheng, Junbo; Huo, Linsheng; Song, Gangbing

    2017-09-29

    With the development of the post-tensioning technique, prestressed concrete structures have been widely used in civil engineering. To ensure the long-term effectiveness of the prestressed tendon, the grouting quality of the tendon duct is one of the important factors. However, it is still a challenge to monitor the grouting quality of post-tensioning tendon ducts, due to the invisibility of the grouting. The authors' previous work proposed a real-time method that employed a stress wave-based active sensing approach with piezoceramic transducers to monitor the grouting compactness of a Post-Tensioning Tendon Duct (PTTD). To further understand the piezoceramic induced stress wave propagation in the PTTD with different grouting levels, this paper develops a two-dimensional finite element model for monitoring the grouting compactness of the tendon duct with a piezoceramic transducer. A smart aggregate (SA) developed to utilize one Lead Zirconate Titanate (PZT) transducer with marble protection is installed in the center location of the tendon duct as an actuator. Two PZT patches are bonded on the bottom and top surface of the tendon duct as the sensors. The analysis results show that the finite element analysis results are in good agreement with the experimental results, which demonstrates that the finite element analysis is feasible and reliable. For the top half of the specimen, not much stress wave could be detected before the full grouting level, except for negligible signals that may propagate through the walls of the tendon duct. When the tendon duct grouting is at 100%, the stress wave propagates to the top of the specimen, and the displacements are symmetric in both left-right and top-bottom directions before the stress waves reach the boundary. The proposed two-dimensional finite element model has the potential to be implemented to simulate the stress wave propagation principle for monitoring grouting compaction of the post-tensioning tendon duct.

  11. Effect of Achilles tendon loading on plantar fascia tension in the standing foot.

    PubMed

    Cheung, Jason Tak-Man; Zhang, Ming; An, Kai-Nan

    2006-02-01

    The plantar fascia, which is one of the major arch-supporting structures of the human foot, sustains high tensions during weight-bearing. A positive correlation between Achilles tendon loading and plantar fascia tension has been reported. Excessive stretching and tightness of the Achilles tendon are thought to be the risk factors of plantar fasciitis but their biomechanical effects on the plantar fascia have not been fully addressed. A three-dimensional finite element model of the human foot and ankle, incorporating geometrical and material nonlinearity, was employed to investigate the loading response of the plantar fascia in the standing foot with different magnitudes of Achilles tendon loading. With the total ground reaction forces of one foot maintained at 350 N to represent half body weight, an increase in Achilles tendon load from (0-700 N) resulted in a general increase in total force and peak plantar pressure at the forefoot of up to about 250%. There was a lateral and anterior shift of the centre of pressure and a reduction in the arch height with an increasing Achilles tendon load as a result of the plantar flexion moment on the calcaneus. From the finite element predictions of simulated balanced standing, Achilles tendon forces of 75% of the total weight on the foot (350 N) were found to provide the closest match of the measured centre of pressure of the subject during balanced standing. Both the weight on the foot and Achilles tendon loading resulted in an increase in tension of the plantar fascia with the latter showing a two-times larger straining effect. Increasing tension on the Achilles tendon is coupled with an increasing strain on the plantar fascia. Overstretching of the Achilles tendon resulting from intense muscle contraction and passive stretching of tight Achilles tendon are plausible mechanical factors for overstraining of the plantar fascia.

  12. Biomaterials based strategies for rotator cuff repair.

    PubMed

    Zhao, Song; Su, Wei; Shah, Vishva; Hobson, Divia; Yildirimer, Lara; Yeung, Kelvin W K; Zhao, Jinzhong; Cui, Wenguo; Zhao, Xin

    2017-09-01

    Tearing of the rotator cuff commonly occurs as among one of the most frequently experienced tendon disorders. While treatment typically involves surgical repair, failure rates to achieve or sustain healing range from 20 to 90%. The insufficient capacity to recover damaged tendon to heal to the bone, especially at the enthesis, is primarily responsible for the failure rates reported. Various types of biomaterials with special structures have been developed to improve tendon-bone healing and tendon regeneration, and have received considerable attention for replacement, reconstruction, or reinforcement of tendon defects. In this review, we first give a brief introduction of the anatomy of the rotator cuff and then discuss various design strategies to augment rotator cuff repair. Furthermore, we highlight current biomaterials used for repair and their clinical applications as well as the limitations in the literature. We conclude this article with challenges and future directions in designing more advanced biomaterials for augmentation of rotator cuff repair. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. MMP inhibition as a potential method to augment the healing of skeletal muscle and tendon extracellular matrix

    PubMed Central

    Davis, Max E.; Gumucio, Jonathan P.; Sugg, Kristoffer B.; Bedi, Asheesh

    2013-01-01

    The extracellular matrix (ECM) of skeletal muscle and tendon is composed of different types of collagen molecules that play important roles in the transmission of forces throughout the body, and in the repair and regeneration of injured tissues. Fibroblasts are the primary cells in muscle and tendon that maintain, repair, and modify the ECM in response to mechanical loading, injury, and inactivity. Matrix metalloproteinases (MMPs) are enzymes that digest collagen and other structural molecules, which are synthesized and excreted by fibroblasts. MMPs are required for baseline ECM homeostasis, but disruption of MMP regulation due to injury or disease can alter the normal ECM architecture and prevent proper force transmission. Chronic injuries and diseases of muscles and tendons can be severely debilitating, and current therapeutic modalities to enhance healing are quite limited. This review will discuss the mechanobiology of MMPs, and the potential use of MMP inhibitors to improve the treatment of injured and diseased skeletal muscle and tendon tissue. PMID:23640595

  14. Engineering tendon and ligament tissues: present developments towards successful clinical products.

    PubMed

    Rodrigues, Márcia T; Reis, Rui L; Gomes, Manuela E

    2013-09-01

    Musculoskeletal diseases are one of the leading causes of disability worldwide. Among them, tendon and ligament injuries represent an important aspect to consider in both athletes and active working people. Tendon and ligament damage is an important cause of joint instability, and progresses into early onset of osteoarthritis, pain, disability and eventually the need for joint replacement surgery. The social and economical burden associated with these medical conditions presents a compelling argument for greater understanding and expanding research on this issue. The particular physiology of tendons and ligaments (avascular, hypocellular and overall structural mechanical features) makes it difficult for currently available treatments to reach a complete and long-term functional repair of the damaged tissue, especially when complete tear occurs. Despite the effort, the treatment modalities for tendon and ligament are suboptimal, which have led to the development of alternative therapies, such as the delivery of growth factors, development of engineered scaffolds or the application of stem cells, which have been approached in this review. Copyright © 2012 John Wiley & Sons, Ltd.

  15. In vitro structural properties of braided tendon grafts.

    PubMed

    Nicklin, S; Waller, C; Walker, P; Chung, W K; Walsh, W R

    2000-01-01

    In an effort to increase strength in hamstring tendon grafts for anterior cruciate ligament reconstruction, braiding or weaving of the tendons has been suggested. The purpose of this study was to examine the biomechanical properties of two braiding techniques compared with a four-stranded tendon graft using a sheep model. Digital extensor tendons from 5 adult sheep were harvested in 28 matched pairs and randomly allocated to French plait or four-stranded weave. The grafts were tested in a hydraulic testing machine with the tendons secured in brass grips frozen with liquid carbon dioxide. The tendons were preconditioned to a distraction of 1 mm for 10 cycles followed by testing to failure at 50 mm/sec, with a data acquisition rate of 1,000 Hz. The stiffness, ultimate load to failure, and the mode of failure were recorded. All braided samples failed at the midsubstance, while the four-stranded controls failed at the grip interface. There was a significant reduction in strength and stiffness of the braided samples compared with the controls. This study demonstrated that braiding decreases the strength and stiffness of a four-stranded tendon graft by up to 54% and 85%, respectively. This finding is supported by the work of Hearle et al. (1969), who demonstrated that the decrease in strength of fiber bundles is equal to the square of the cosine of the twist angle. The twist angle in our samples was approximately 45 degrees, which equates to a decrease in strength of 50%.

  16. The myoseptal system in Chimaera monstrosa: collagenous fiber architecture and its evolution in the gnathostome stem lineage.

    PubMed

    Gemballa, Sven; Hagen, Katja

    2004-01-01

    Recent studies have revealed the 3D morphology and collagen fiber architecture of myosepta in teleostome fishes. Here we present the first data set on the myoseptal structure of a representative of the chondrichthyan clade. We investigate the series of myosepta in the ratfish Chimaera monstrosa (Holocephali) from the anterior to the posterior body using microdissections of cleared and stained specimens, polarized light microscopy of excised myosepta, and histology. The features of the myoseptal system of Chimaera are compared to data from closely related vertebrate groups and are mapped onto a phylogenetic tree to further clarify the characteristics of the myoseptal series in the gnathostome ancestor. The 3D morphology and collagen fiber architecture of the myoseptal series in C. monstrosa resembles that of Teleostomi (Actinopterygii+Sarcopterygii) with regard to several features. Our comparative analysis reveals that some of them have evolved in the gnathostome stem lineage. (1) A series of epineural and epaxial lateral tendons (LTs) along the whole body, and a series of epipleural and hypaxial LTs in the postanal region evolved in the gnathostome stem lineage. (2) The LTs increase in length towards the posterior body (three-fold in Chimaera). Data on Chimaera and some comparative data on actinopterygian fishes indicate that LTs also increase in thickness towards the posterior body, but further data are necessary to test whether this holds true generally. (3) Another conspicuous apomorphic gnathostome feature is represented by multi-layer structures of myosepta. These are formed along the vertebral column by converging medial regions of successive sloping parts of myosepta. (4) The dorsalmost and ventralmost flanking parts of myosepta bear a set of mediolaterally oriented collagen fibers that are present in all gnathostomes but are lacking in outgroups. Preanal hypaxial myosepta are clearly different from epaxial myosepta and postanal hypaxial myosepta in terms of their collagen fiber architecture. In Chimaera, preanal hypaxial myosepta consist of an array of mediolaterally oriented collagen fibers closely resembling the condition in other gnathostome groups and in petromyzontids. Only one series of tendons, the myorhabdoid tendons of the flanking parts of myosepta, have evolved in the stem lineage of Myopterygii (Gnathostomata+Petromyzontida). Similar to LTs, the tendons of this series also increase in length towards the posterior body. In combination with other studies, the present study provides a framework for the design of morphologically based experiments and modeling to further address the function of myosepta and myoseptal tendons in gnathostomes.

  17. Diagnosis and treatment of infraspinatus tendon-bursa ossification in a Eurasian Dog.

    PubMed

    Ungru, Julia; Hungerbühler, Stephan; Henninger, Wolfgang; Klupiec, Petra; Bödeker, Julia; Langer, Anna; Fehr, Michael; Harms, Oliver

    2018-04-01

    A 4-year-old male Eurasian Dog presented at our veterinary clinic with a history of perpetual forelimb lameness in both thoracic limbs. In the clinical exploration, direct pressure over the infraspinatus tendon of insertion caused pain in both thoracic forelimbs and a firm band-like structure was palpable. No improvement was observed after treatment with rest, non-steroidal anti-inflammatory drugs and an intralesional injection of a long-acting glucocorticoid. Radiographic examination, ultrasonographic exploration and computed tomography were performed, identifying ossified structures lateral to the proximal humerus and an irregular roughened periosteum at the insertion and tendon of the infraspinatus muscle on both sides. There were more distinct alterations on the right thoracic limb. The imaging results led to a diagnosis of an infraspinatus tendon-bursa ossification accompanied by a chronic tendinopathy/tendovaginitis, accentuated on the right side. The dog was subjected to physiotherapy and autologous conditioned plasma (ACP) was injected into the insertion of the infraspinatus muscle of both thoracic limbs. After 5 months of physiotherapy and two injections of ACP with an interval of one week in both forelimbs, the dog showed no signs of lameness. This case report describes the diagnosis and management of infraspinatus tendon-bursa ossification in a Eurasian Dog. To the authors' knowledge, this condition has previously not been described in this breed of dog. Schattauer GmbH.

  18. A magnetic resonance imaging study of abnormalities of the patella and patellar tendon that predispose children to acute patellofemoral dislocation.

    PubMed

    Yılmaz, Barış; Çiçek, Esin Derin; Şirin, Evrim; Özdemir, Güzelali; Karakuş, Özgün; Muratlı, Hasan Hilmi

    This study compared 20 children hospitalised with acute patellofemoral dislocation with an age-matched healthy control group with no history of knee problems or patellar dislocation. The following morphological parameters were significantly different between the groups: the mean patellar width and length, mean sulcus depth, mean patellar tendon width and total patellar volume. The magnetic resonance imaging findings of this study suggested that structurally smaller than normal patella and patellar tendon volumes are predisposing factors for acute patellofemoral dislocation. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Rotator cuff disorders: How to write a surgically relevant magnetic resonance imaging report?

    PubMed Central

    Tawfik, Ahmed M; El-Morsy, Ahmad; Badran, Mohamed Aboelnour

    2014-01-01

    Evaluation of rotator cuff is a common indication for magnetic resonance imaging (MRI) scanning of the shoulder. Conventional MRI is the most commonly used technique, while magnetic resonance (MR) arthrography is reserved for certain cases. Rotator cuff disorders are thought to be caused by a combination of internal and external mechanisms. A well-structured MRI report should comment on the relevant anatomic structures including the acromial type and orientation, the presence of os acromiale, acromio-clavicular degenerative spurs and fluid in the subacromial subdeltoid bursa. In addition, specific injuries of the rotator cuff tendons and the condition of the long head of biceps should be accurately reported. The size and extent of tendon tears, tendon retraction and fatty degeneration or atrophy of the muscles are all essential components of a surgically relevant MRI report. PMID:24976930

  20. [Three-dimensional parallel collagen scaffold promotes tendon extracellular matrix formation].

    PubMed

    Zheng, Zefeng; Shen, Weiliang; Le, Huihui; Dai, Xuesong; Ouyang, Hongwei; Chen, Weishan

    2016-03-01

    To investigate the effects of three-dimensional parallel collagen scaffold on the cell shape, arrangement and extracellular matrix formation of tendon stem cells. Parallel collagen scaffold was fabricated by unidirectional freezing technique, while random collagen scaffold was fabricated by freeze-drying technique. The effects of two scaffolds on cell shape and extracellular matrix formation were investigated in vitro by seeding tendon stem/progenitor cells and in vivo by ectopic implantation. Parallel and random collagen scaffolds were produced successfully. Parallel collagen scaffold was more akin to tendon than random collagen scaffold. Tendon stem/progenitor cells were spindle-shaped and unified orientated in parallel collagen scaffold, while cells on random collagen scaffold had disorder orientation. Two weeks after ectopic implantation, cells had nearly the same orientation with the collagen substance. In parallel collagen scaffold, cells had parallel arrangement, and more spindly cells were observed. By contrast, cells in random collagen scaffold were disorder. Parallel collagen scaffold can induce cells to be in spindly and parallel arrangement, and promote parallel extracellular matrix formation; while random collagen scaffold can induce cells in random arrangement. The results indicate that parallel collagen scaffold is an ideal structure to promote tendon repairing.

  1. Cathepsins in Rotator Cuff Tendinopathy: Identification in Human Chronic Tears and Temporal Induction in a Rat Model.

    PubMed

    Seto, Song P; Parks, Akia N; Qiu, Yongzhi; Soslowsky, Louis J; Karas, Spero; Platt, Manu O; Temenoff, Johnna S

    2015-09-01

    While overuse of the supraspinatus tendon is a leading factor in rotator cuff injury, the underlying biochemical changes have not been fully elucidated. In this study, torn human rotator cuff (supraspinatus) tendon tissue was analyzed for the presence of active cathepsin proteases with multiplex cysteine cathepsin zymography. In addition, an overuse injury to supraspinatus tendons was induced through downhill running in an established rat model. Histological analysis demonstrated that structural damage occurred by 8 weeks of overuse compared to control rats in the region of tendon insertion into bone. In both 4- and 8-week overuse groups, via zymography, there was approximately a 180% increase in cathepsin L activity at the insertion region compared to the controls, while no difference was found in the midsubstance area. Additionally, an over 400% increase in cathepsin K activity was observed for the insertion region of the 4-week overused tendons. More cathepsin K and L immunostaining was observed at the insertion region of the overuse groups compared to controls. These results provide important information on a yet unexplored mechanism for tendon degeneration that may operate alone or in conjunction with other proteases to contribute to chronic tendinopathy.

  2. Cathepsins in Rotator Cuff Tendinopathy: Identification in Human Chronic Tears and Temporal Induction in a Rat Model

    PubMed Central

    Seto, Song P.; Parks, Akia N.; Qiu, Yongzhi; Soslowsky, Louis J.; Karas, Spero; Platt, Manu O.; Temenoff, Johnna S.

    2015-01-01

    While overuse of the supraspinatus tendon is a leading factor in rotator cuff injury, the underlying biochemical changes have not been fully elucidated. In this study, torn human rotator cuff (supraspinatus) tendon tissue was analyzed for the presence of active cathepsin proteases with multiplex cysteine cathepsin zymography. In addition, an overuse injury to supraspinatus tendons was induced through downhill running in an established rat model. Histological analysis demonstrated that structural damage occurred by 8 weeks of overuse compared to control rats in the region of tendon insertion into bone. In both 4- and 8-week overuse groups, via zymography, there was approximately a 180% increase in cathepsin L activity at the insertion region compared to the controls, while no difference was found in the midsubstance area. Additionally, an over 400% increase in cathepsin K activity was observed for the insertion region of the 4-week overused tendons. More cathepsin K and L immunostaining was observed at the insertion region of the overuse groups compared to controls. These results provide important information on a yet unexplored mechanism for tendon degeneration that may operate alone or in conjunction with other proteases to contribute to chronic tendinopathy. PMID:25558848

  3. Structural Integration and Control of Peerless Human-like Prosthetic Hand

    NASA Astrophysics Data System (ADS)

    Dave, Ankit; Muthu, P.; Karthikraj, V.; Latha, S.

    2018-04-01

    Limb damage can create severe disturbance in movement and operative abilities wherein the prosthetic rehabilitation has the potential to replace function and enhance the quality of life. This paper presents a humanlike prosthetic hand using such unique design concept of hand model using artificial bones, ligaments, and tendons controlled using Arduino. Amongst various platforms available, Arduino is known for its adaptability, adoration and low cost. The design of prosthetic hand has a unique structure with all carpal, metacarpal, and phalanges which are bones of the hand. These bones are attached to each other following the pattern of human hand using the polymeric rubber as a functioning ligament. Furthermore, this structure of finger is driven by tendons attached to all fingers and passes through the ligaments working as pulley resulting in more degrees of freedom. The motor can twitch the tendons to achieve the action of fingers. Thus the servos, controlled by an Arduino, are used to regulate the movement mechanism of the prosthetic hand.

  4. Degree of tendon degeneration and stage of rotator cuff disease.

    PubMed

    Jo, Chris Hyunchul; Shin, Won Hyoung; Park, Ji Wan; Shin, Ji Sun; Kim, Ji Eun

    2017-07-01

    While tendon degeneration has been known to be an important cause of rotator cuff disease, few studies have objectively proven the association of tendon degeneration and rotator cuff disease. The purpose of this study was to investigate changes of tendon degeneration with respect to the stage of rotator cuff disease. A total of 48 patients were included in the study: 12 with tendinopathy, 12 with a partial-thickness tear (pRCT), 12 with a full-thickness tear (fRCT), and 12 as the control. A full-thickness supraspinatus tendon sample was harvested en bloc from the middle portion between the lateral edge and the musculotendinous junction of the tendon using a biopsy punch with a diameter of 3 mm. Harvested samples were evaluated using a semi-quantitative grading scale with 7 parameters after haematoxylin and eosin staining. There was no significant difference in age, gender, symptom duration, and Kellgren-Lawrence grade between the groups except for the global fatty degeneration index. All of the seven parameters were significantly different between the groups and could be categorized as follows: early responders (fibre structure and arrangement), gradual responder (rounding of the nuclei), after-tear responders (cellularity, vascularity, and stainability), and late responder (hyalinization). The total degeneration scores were not significantly different between the control (6.08 ± 1.16) and tendinopathy (6.67 ± 1.83) (n.s.). However, the score of pRCT group (10.42 ± 1.31) was greater than that of tendinopathy (P < 0.001), and so was the score of fRCT (12.33 ± 1.15) than that of pRCT (p = 0.009). This study showed that the degeneration of supraspinatus tendon increases as the stage of rotator cuff disease progresses from tendinopathy to pRCT, and then to fRCT. The degree of degeneration of tendinopathy was not different from that of normal but aged tendons, and significant tendon degeneration began from the stage of pRCT. The clinical relevance of the study is that strategies and goals of the treatment for rotator cuff disease should be specific to its stage, in order to prevent disease progression for tendinopathy and pRCT, as well to restore the structural integrity for fRCT. Diagnostic, Level I.

  5. History-dependence of muscle slack length following contraction and stretch in the human vastus lateralis.

    PubMed

    Stubbs, Peter W; Walsh, Lee D; D'Souza, Arkiev; Héroux, Martin E; Bolsterlee, Bart; Gandevia, Simon C; Herbert, Robert D

    2018-06-01

    In reduced muscle preparations, the slack length and passive stiffness of muscle fibres have been shown to be influenced by previous muscle contraction or stretch. In human muscles, such behaviours have been inferred from measures of muscle force, joint stiffness and reflex magnitudes and latencies. Using ultrasound imaging, we directly observed that isometric contraction of the vastus lateralis muscle at short lengths reduces the slack lengths of the muscle-tendon unit and muscle fascicles. The effect is apparent 60 s after the contraction. These observations imply that muscle contraction at short lengths causes the formation of bonds which reduce the effective length of structures that generate passive tension in muscles. In reduced muscle preparations, stretch and muscle contraction change the properties of relaxed muscle fibres. In humans, effects of stretch and contraction on properties of relaxed muscles have been inferred from measurements of time taken to develop force, joint stiffness and reflex latencies. The current study used ultrasound imaging to directly observe the effects of stretch and contraction on muscle-tendon slack length and fascicle slack length of the human vastus lateralis muscle in vivo. The muscle was conditioned by (a) strong isometric contractions at long muscle-tendon lengths, (b) strong isometric contractions at short muscle-tendon lengths, (c) weak isometric contractions at long muscle-tendon lengths and (d) slow stretches. One minute after conditioning, ultrasound images were acquired from the relaxed muscle as it was slowly lengthened through its physiological range. The ultrasound image sequences were used to identify muscle-tendon slack angles and fascicle slack lengths. Contraction at short muscle-tendon lengths caused a mean 13.5 degree (95% CI 11.8-15.0 degree) shift in the muscle-tendon slack angle towards shorter muscle-tendon lengths, and a mean 5 mm (95% CI 2-8 mm) reduction in fascicle slack length, compared to the other conditions. A supplementary experiment showed the effect could be demonstrated if the muscle was conditioned by contraction at short lengths but not if the relaxed muscle was held at short lengths, confirming the role of muscle contraction. These observations imply that muscle contraction at short lengths causes the formation of bonds which reduce the effective length of structures that generate passive tension in muscles. © 2018 The Authors. The Journal of Physiology © 2018 The Physiological Society.

  6. Fetal derived embryonic-like stem cells improve healing in a large animal flexor tendonitis model

    PubMed Central

    2011-01-01

    Introduction Tendon injury is a common problem in athletes, with poor tissue regeneration and a high rate of re-injury. Stem cell therapy is an attractive treatment modality as it may induce tissue regeneration rather than tissue repair. Currently, there are no reports on the use of pluripotent cells in a large animal tendon model in vivo. We report the use of intra-lesional injection of male, fetal derived embryonic-like stem cells (fdESC) that express Oct-4, Nanog, SSEA4, Tra 1-60, Tra 1-81 and telomerase. Methods Tendon injury was induced using a collagenase gel-physical defect model in the mid-metacarpal region of the superficial digital flexor tendon (SDFT) of eight female adult Thoroughbred or Thoroughbred cross horses. Tendon lesions were treated one week later with intra-lesional injection of male derived fdESCs in media or media alone. Therapy was blinded and randomized. Serial ultrasound examinations were performed and final analysis at eight weeks included magnetic resonance imaging (MRI), biochemical assays (total DNA, glycosaminoglycan, collagen), gene expression (TNC, TNMD, SCX, COL1A1, COL3A1, COMP, DCN, MMP1, MMP3, MMP13, 18S) and histology. Differences between groups were assessed with Wilcoxon's rank sum test. Results Cell survival was demonstrated via the presence of the SRY gene in fdESC treated, but not control treated, female SDFT at the end of the trial. There were no differences in tendon matrix specific gene expression or total proteoglycan, collagen or DNA of tendon lesions between groups. Tissue architecture, tendon size, tendon lesion size, and tendon linear fiber pattern were significantly improved on histologic sections and ultrasound in the fdESC treated tendons. Conclusions Such profound structural effects lend further support to the notion that pluripotent stem cells can effect musculoskeletal regeneration, rather than repair, even without in vitro lineage specific differentiation. Further investigation into the safety of pluripotent cellular therapy as well as the mechanisms by which repair was improved seem warranted. PMID:21272343

  7. Lateral Knee Compartment Portals: A Cadaveric Study Defining a Posterolateral Viewing Safety Zone.

    PubMed

    Dilworth, Brian; Fehrenbacher, Victor; Nyland, John; Clark, Jamie; Greene, Joseph W

    2018-04-12

    This study attempted to define a reproducible "safe zone" based on extra- and intra-articular knee anatomy for placing one or 2 accessory portals in the lateral tibiofemoral compartment for posterolateral region viewing. Standard portals were created in 10 cadaveric knees to enable posterolateral region arthroscopic lateral tibiofemoral joint compartment viewing. After identifying the lateral knee surface tissue "soft spot," an accessory posterolateral portal (A) was created using an 18-gauge spinal needle and 4-mm cannula under direct visualization of a 70° arthroscope through the anteromedial portal. A second accessory portal (B) was then created 1 cm posterior and 1 cm superior to portal A. Accessory portal locations were measured relative to capsular fold and popliteus tendon locations. Distances from the peroneal nerve, lateral collateral ligament, popliteus tendon, and the biceps tendon were determined. Statistical analysis compared portal location differences from key anatomical structures (P < .05). Accessory portal A (mean ± 95% confidence interval) was located 8.8 ± 2.7 mm from the popliteus tendon, 11.6 ± 2.7 mm from the lateral collateral ligament (LCL), 26.8 ± 2.3 mm from the peroneal nerve, and 4.9 ± 2.5 mm from the biceps tendon. Accessory portal B was located 17.3 ± 2.8 mm from the popliteus tendon, 20 ± 2.8 mm from the LCL, 30.3 ± 3.3 mm from the peroneal nerve, and 7.0 ± 4.8 mm from the biceps tendon. Accessory portal B was located a greater distance from the LCL and the popliteus tendon than portal A (P < .0001). Using intra- and extra-articular anatomic landmarks, both accessory portals could be safely placed in the lateral tibiofemoral joint compartment to enable posterolateral region viewing. Accessory portals used individually or in combination may enable easier posterolateral region viewing for arthroscopic repair of lateral tibiofemoral compartment structures. Lateral tibiofemoral compartment portals can be safely created to enable improved visibility for complex arthroscopic procedures in the posterolateral viewing region. Copyright © 2018 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  8. Evaluation of the histological and mechanical features of tendon healing in a rabbit model with the use of second-harmonic-generation imaging and tensile testing.

    PubMed

    Hase, E; Sato, K; Yonekura, D; Minamikawa, T; Takahashi, M; Yasui, T

    2016-11-01

    This study aimed to evaluate the histological and mechanical features of tendon healing in a rabbit model with second-harmonic-generation (SHG) imaging and tensile testing. A total of eight male Japanese white rabbits were used for this study. The flexor digitorum tendons in their right leg were sharply transected, and then were repaired by intratendinous stitching. At four weeks post-operatively, the rabbits were killed and the flexor digitorum tendons in both right and left legs were excised and used as specimens for tendon healing (n = 8) and control (n = 8), respectively. Each specimen was examined by SHG imaging, followed by tensile testing, and the results of the two testing modalities were assessed for correlation. While the SHG light intensity of the healing tendon samples was significantly lower than that of the uninjured tendon samples, 2D Fourier transform SHG images showed a clear difference in collagen fibre structure between the uninjured and the healing samples, and among the healing samples. The mean intensity of the SHG image showed a moderate correlation (R 2 = 0.37) with Young's modulus obtained from the tensile testing. Our results indicate that SHG microscopy may be a potential indicator of tendon healing.Cite this article: E. Hase, K. Sato, D. Yonekura, T. Minamikawa, M. Takahashi, T. Yasui. Evaluation of the histological and mechanical features of tendon healing in a rabbit model with the use of second-harmonic-generation imaging and tensile testing. Bone Joint Res 2016;5:577-585. DOI: 10.1302/2046-3758.511.BJR-2016-0162.R1. © 2016 Yasui et al.

  9. Investigation of a tissue engineered tendon model by PS-OCT

    NASA Astrophysics Data System (ADS)

    Yang, Ying; Ahearne, Mark; Wimpenny, Ian; Guijarro-Leach, Juan; Torbet, Jim

    2010-02-01

    A few native tissues, such as tendon, skin and eye, possess highly organized collagenous matrices. In particular, the collagen fibers in tendon are organized into a hierarchical and unidirectional format, which gives rise to the high tissuespecific mechanical properties. This organization has been clearly revealed by a conventional polarized light microscope. The newly developed polarization-sensitive optical coherence tomography (PS-OCT) technique allows non-invasive visualization of birefringence images arising from orientated structures in a three dimensional format. Our previous studies of native tendon and tissue engineered tendon by PS-OCT demonstrate that tissue engineered tendon has a far less perfect collagen fiber organization than native tendon even under dynamic culture conditions. The purpose of this study is to use PS-OCT to assess the relationship between the degree of birefringence, collagen concentration and fiber density in model tendon tissues. The model tissue is constructed from an aligned collagen hydrogel and aligned polyester nanofibers. The effects of the diameter and density of the nanofibers and the collagen concentration in the model have been investigated. The alignment of collagen fibrils is induced by application of a high magnetic field during fibrillogenesis while aligned polyester nanofibers are manufactured using the electrospinning technique. It is found that the collagen concentration, the density and size of nanofiber bundles are the key parameters to produce birefringence in OCT images. The perfectly aligned collagen hydrogel with concentration as high as 4 mg/ml does not exhibit a birefringence image until the hydrogel has been compressed and concentrated. Aligned nanofiber bundles have demonstrated marginal birefringence in the absence of the collagen matrix. These studies enhance our understanding of how to control and optimize the parameters in tendon tissue engineering.

  10. [Tendinosis and ruptures of the Achilles tendon].

    PubMed

    Amlang, M H; Zwipp, H

    2012-02-01

    Tendinosis of the Achilles tendon is a degenerative-reparative structural change of the tendon with microdefects, increases in cross-section due to cicatricial tendon regeneration, neoangiogenesis and reduction of elasticity. The previously used term tendinitis is only rarely used for the chronic form since signs of inflammation such as redness and hyperthermia or elevated levels of inflammatory parameters on laboratory testing are generally absent. Duplex sonography with visualization of the neovascularization has become a valuable supplement not only for diagnostics but also for therapy planning. The classic, conservative therapy for painful tendinosis consists of oral anti-inflammatory drugs, pain-adapted load reduction, raising the heel, stretching the calf musculature, and various physiotherapeutic interventions. When conservative treatment over a period of 4 - 6 months fails to produce any or non-adequate pain relief, an indication for surgical treatment should be considered. In the therapy for fresh ruptures of the Achilles tendon further developments in minimally invasive techniques have led to a worldwide paradigm change over the past 10 years. The decisive advantage of minimally invasive surgical techniques is the lower risk of wound infection as compared to the sutures of the open technique. When compared with conservative functional therapy the minimally invasive repair has the advantage of being less dependent on the compliance of the patient since, in the early phase of tendon healing the suture prevents a separation of the tendon ends upon controlled movements. However, not every patient with a ruptured Achilles tendon should be treated with a minimally invasive repair. Open tendon reconstruction and functional conservative therapy are still justified when the correct indication is given. © Georg Thieme Verlag KG Stuttgart · New York.

  11. Acute first-time hamstring strains during slow-speed stretching: clinical, magnetic resonance imaging, and recovery characteristics.

    PubMed

    Askling, Carl M; Tengvar, Magnus; Saartok, Tönu; Thorstensson, Alf

    2007-10-01

    Hamstring strains can be of 2 types with different injury mechanisms, 1 occurring during high-speed running and the other during stretching exercises. A stretching type of injury to the proximal rear thigh may involve specific muscle-tendon structures that could affect recovery time. Case series (prognosis); Level of evidence, 2. Fifteen professional dancers with acute first-time hamstring strains were prospectively included in the study. All subjects were examined, clinically and with magnetic resonance imaging, on 4 occasions after injury: at day 2 to 4, 10, 21, and 42. The clinical follow-up period was 2 years. All dancers were injured during slow hip-flexion movements with extended knee and experienced relatively mild acute symptoms. All injuries were located proximally in the posterior thigh close to the ischial tuberosity. The injury involved the semimembranosus (87%), quadratus femoris (87%), and adductor magnus (33%). All injuries to the semimembranosus involved its proximal free tendon. There were no significant correlations between clinical or magnetic resonance imaging parameters and the time to return to preinjury level (median, 50 weeks; range, 30-76 weeks). Stretching exercises can give rise to a specific type of strain injury to the posterior thigh. A precise history and careful palpation provide the clinician enough information to predict a prolonged time until return to preinjury level. One factor underlying prolonged recovery time could be the involvement of the free tendon of the semimembranosus muscle.

  12. Isolated Subscapularis Repair in Irreparable Posterosuperior Massive Rotator Cuff Tears Involving the Subscapularis Tendon.

    PubMed

    Kim, Sung-Jae; Choi, Yun-Rak; Jung, Min; Lee, Won-Yong; Chun, Yong-Min

    2017-05-01

    No previous study has examined whether isolated subscapularis tendon repair in irreparable posterosuperior massive rotator tears involving the subscapularis tendon in relatively young patients without arthritis can yield satisfactory outcomes. We hypothesized that this procedure would produce favorable outcomes in patients who might otherwise be candidates for reverse arthroplasty. Case series; Level of evidence, 4. This retrospective study included 24 patients in their 50s and 60s, without shoulder arthritis, who underwent arthroscopic isolated subscapularis repair for an irreparable massive rotator cuff tear involving the subscapularis tendon. Preoperative and postoperative visual analog scale (VAS) pain scores, subjective shoulder values (SSVs), University of California at Los Angeles (UCLA) shoulder scores, American Shoulder and Elbow Surgeons (ASES) scores, subscapularis strength (modified bell-press test; maximum of 5), and shoulder active range of motion (ROM) were assessed. Postoperative magnetic resonance arthrography (MRA) was performed 6 months postoperatively to assess structural integrity of the repaired subscapularis. At a mean 34.8 months (range, 24-49 months) of follow-up, VAS pain scores (improved from 7.1 to 2.5), SSVs (33.3 to 75.2), ASES scores (35.9 to 76.0), UCLA shoulder scores (11.6 to 24.8), subscapularis strength, and ROM were significantly improved compared with preoperative measurements ( P < .001). Subscapularis muscle strength improved from 3.7 to 4.2 ( P < .001). For active ROM, forward flexion and internal rotation improved significantly ( P < .001); however, external rotation exhibited no significant improvement. Follow-up MRA was performed in 22 patients (92%) and showed retear of the repaired subscapularis in 6 (27% of the 22). Isolated repair of the subscapularis tendon in irreparable massive rotator cuff tears involving the subscapularis tendon yielded satisfactory short-term outcomes and structural integrity in patients in their 50s and 60s without arthritis. If patients with irreparable massive rotator cuff tears involving the subscapularis tendon are relatively young or have minimal concomitant arthritis, this repair can be worthwhile.

  13. Composition and structure of porcine digital flexor tendon-bone insertion tissues.

    PubMed

    Chandrasekaran, Sandhya; Pankow, Mark; Peters, Kara; Huang, Hsiao-Ying Shadow

    2017-11-01

    Tendon-bone insertion is a functionally graded tissue, transitioning from 200 MPa tensile modulus at the tendon end to 20 GPa tensile modulus at the bone, across just a few hundred micrometers. In this study, we examine the porcine digital flexor tendon insertion tissue to provide a quantitative description of its collagen orientation and mineral concentration by using Fast Fourier Transform (FFT) based image analysis and mass spectrometry, respectively. Histological results revealed uniformity in global collagen orientation at all depths, indicative of mechanical anisotropy, although at mid-depth, the highest fiber density, least amount of dispersion, and least cellular circularity were evident. Collagen orientation distribution obtained through 2D FFT of histological imaging data from fluorescent microscopy agreed with past measurements based on polarized light microscopy. Results revealed global fiber orientation across the tendon-bone insertion to be preserved along direction of physiologic tension. Gradation in the fiber distribution orientation index across the insertion was reflective of a decrease in anisotropy from the tendon to the bone. We provided elemental maps across the fibrocartilage for its organic and inorganic constituents through time-of-flight secondary ion mass spectrometry (TOF-SIMS). The apatite intensity distribution from the tendon to bone was shown to follow a linear trend, supporting past results based on Raman microprobe analysis. The merit of this study lies in the image-based simplified approach to fiber distribution quantification and in the high spatial resolution of the compositional analysis. In conjunction with the mechanical properties of the insertion tissue, fiber, and mineral distribution results for the insertion from this may potentially be incorporated into the development of a structural constitutive approach toward computational modeling. Characterizing the properties of the native insertion tissue would provide the microstructural basis for developing biomimetic scaffolds to recreate the graded morphology of a fibrocartilaginous insertion. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 3050-3058, 2017. © 2017 Wiley Periodicals, Inc.

  14. Carbon-14 bomb pulse dating shows that tendinopathy is preceded by years of abnormally high collagen turnover.

    PubMed

    Heinemeier, Katja Maria; Schjerling, Peter; Øhlenschlæger, Tommy F; Eismark, Christian; Olsen, Jesper; Kjær, Michael

    2018-03-23

    Tendons are essential weight-bearing structures that are often affected by tendinopathy, which leads to pain and impaired mobility. In healthy Achilles tendons, no significant renewal of the weight-bearing collagen matrix seems to occur during adult life, but tendinopathy may lead to increased turnover. The carbon-14 ([ 14 C]) bomb pulse method was used to measure lifelong replacement rates of collagen in tendinopathic and healthy Achilles tendons (tendinopathic: n = 25, born 1937-72. Healthy: n = 10, born 1929-66). As expected, the healthy tendon collagen had not been replaced during adulthood, but in tendinopathic tendon, a substantial renewal had occurred. Modeling of the [ 14 C] data suggested that one half of the collagen in tendinopathic matrix had undergone continuous slow turnover for years before the presentation of symptoms. This finding allows for a new concept in tendon pathogenesis because it suggests that either the symptoms of tendinopathy represent a late phase of a very prolonged disease process, or an abnormally high collagen exchange could be a risk factor for tendon disorders rather than being a result of disease.-Heinemeier, K. M., Schjerling, P., Øhlenschlæger, T. F., Eismark, C., Olsen, J., Kjær, M. Carbon-14 bomb pulse dating shows that tendinopathy is preceded by years of abnormally high collagen turnover.

  15. A Clinical, Biological, and Biomaterials Perspective into Tendon Injuries and Regeneration

    PubMed Central

    Walden, Grace; Liao, Xin; Donell, Simon; Raxworthy, Mike J.; Riley, Graham P.

    2017-01-01

    Tendon injury is common and debilitating, and it is associated with long-term pain and ineffective healing. It is estimated to afflict 25% of the adult population and is often a career-ending disease in athletes and racehorses. Tendon injury is associated with high morbidity, pain, and long-term suffering for the patient. Due to the low cellularity and vascularity of tendon tissue, once damage has occurred, the repair process is slow and inefficient, resulting in mechanically, structurally, and functionally inferior tissue. Current treatment options focus on pain management, often being palliative and temporary and ending in reduced function. Most treatments available do not address the underlying cause of the disease and, as such, are often ineffective with variable results. The need for an advanced therapeutic that addresses the underlying pathology is evident. Tissue engineering and regenerative medicine is an emerging field that is aimed at stimulating the body's own repair system to produce de novo tissue through the use of factors such as cells, proteins, and genes that are delivered by a biomaterial scaffold. Successful tissue engineering strategies for tendon regeneration should be built on a foundation of understanding of the molecular and cellular composition of healthy compared with damaged tendon, and the inherent differences seen in the tissue after disease. This article presents a comprehensive clinical, biological, and biomaterials insight into tendon tissue engineering and regeneration toward more advanced therapeutics. PMID:27596929

  16. Inflammatory process induced by carrageenan in adjacent tissue triggers the acute inflammation in deep digital flexor tendon of rats.

    PubMed

    Vieira, Cristiano Pedrozo; De Aro, Andrea Aparecida; Da Ré Guerra, Flávia; De Oliveira, Letícia Prado; De Almeida, Marcos Dos Santos; Pimentel, Edson Rosa

    2013-08-01

    Tendinopathy is a pathology found mainly in the rotator cuff, patellar, Achilles and flexor tendons. Tendinopathy is a significant impediment to performance in athletes and in workers in the labor market. Some studies have indicated that inflammation in adjacent tissues may affect the rotator cuff and Achilles tendon. In this study alterations were verified in the extracellular matrix (ECM) of the deep digital flexor tendon after two periods (12 and 24 hr) of induction inflammation in rat paw. Wistar rats were divided into three groups: those that received injection of 1% carrageenan; those that received 0.9% NaCl; and those that received no application. The tendon was divided into distal (d), proximal (p), and intermediate (i) regions. Biochemical analyses were performed and included non-collagenous proteins (NCP), glycosaminoglycans (GAGs), hydroxyproline (HoPro) and metalloproteinases 2 and 9. Tissue sections were stained with toluidine blue, hematoxylin-eosin, and Ponceau SS and observed under polarization microscopy. Remarkable results were detected that included the presence of MMP-9, degradation of NCP and GAG and the presence of cellular infiltrate closer to digits in d region. The different concentrations of HoPro, as well as alterations in the organization of the collagen fibers showed the collagenous matrix undergoing some alterations. The results indicated that the induced inflammation in rat paw exhibited characteristics similar to the typical acute inflammatory process observed in tendons. Copyright © 2013 Wiley Periodicals, Inc.

  17. Ultrasonographic Evaluation of Zone II Partial Flexor Tendon Lacerations of the Fingers: A Cadaveric Study.

    PubMed

    Kazmers, Nikolas H; Gordon, Joshua A; Buterbaugh, Kristen L; Bozentka, David J; Steinberg, David R; Khoury, Viviane

    2018-04-01

    Accurate assessment of zone II partial flexor tendon lacerations in the finger is clinically important. Surgical repair is recommended for lacerations of greater than 50% to 60%. Our goal was to evaluate ultrasonographic test characteristics and accuracy in identifying partial flexor tendon lacerations in a cadaveric model. From fresh-frozen above-elbow human cadaveric specimens, 32 flexor digitorum profundus tendons were randomly selected to remain intact or receive low- or high-grade lacerations involving 10% to 40% and 60% to 90% of the radioulnar width within Verdan Zone II, respectively. Static and dynamic ultrasonography using a linear array 14-MHz transducer was performed by a blinded musculoskeletal radiologist. Sensitivities, specificities, and other standard test performance metrics were calculated. Actual and measured percentages of tendon laceration were compared by the paired t test. After randomization, 24 tendons were lacerated (12 low- and 12 high-grade), whereas 8 remained intact. The sensitivity and specificity in detecting the presence versus absence of a partial laceration were 0.54 and 0.75, respectively, with positive and negative likelihood ratio values of 2.17 and 0.61. For low-grade lacerations, the sensitivity and specificity were 0.25 and 0.85, compared to 0.83 and 0.85 for high-grade lacerations. Ultrasonography underestimated the percentage of tendon involvement by a mean of 18.1% for the study population as a whole (95% confidence interval, 9.0% to 27.2%; P < .001) but accurately determined the extent for correctly diagnosed high-grade lacerations (-6.7%; 95% confidence interval, -18.7% to 5.2%; P = .22). Ultrasonography was useful in identifying and characterizing clinically relevant high-grade zone II partial flexor digitorum profundus lacerations in a cadaveric model. © 2017 by the American Institute of Ultrasound in Medicine.

  18. Changes in skeletal muscle and tendon structure and function following genetic inactivation of myostatin in rats

    PubMed Central

    Mendias, Christopher L; Lynch, Evan B; Gumucio, Jonathan P; Flood, Michael D; Rittman, Danielle S; Van Pelt, Douglas W; Roche, Stuart M; Davis, Carol S

    2015-01-01

    Myostatin is a negative regulator of skeletal muscle and tendon mass. Myostatin deficiency has been well studied in mice, but limited data are available on how myostatin regulates the structure and function of muscles and tendons of larger animals. We hypothesized that, in comparison to wild-type (MSTN+/+) rats, rats in which zinc finger nucleases were used to genetically inactivate myostatin (MSTNΔ/Δ) would exhibit an increase in muscle mass and total force production, a reduction in specific force, an accumulation of type II fibres and a decrease and stiffening of connective tissue. Overall, the muscle and tendon phenotype of myostatin-deficient rats was markedly different from that of myostatin-deficient mice, which have impaired contractility and pathological changes to fibres and their extracellular matrix. Extensor digitorum longus and soleus muscles of MSTNΔ/Δ rats demonstrated 20–33% increases in mass, 35–45% increases in fibre number, 20–57% increases in isometric force and no differences in specific force. The insulin-like growth factor-1 pathway was activated to a greater extent in MSTNΔ/Δ muscles, but no substantial differences in atrophy-related genes were observed. Tendons of MSTNΔ/Δ rats had a 20% reduction in peak strain, with no differences in mass, peak stress or stiffness. The general morphology and gene expression patterns were similar between tendons of both genotypes. This large rodent model of myostatin deficiency did not have the negative consequences to muscle fibres and extracellular matrix observed in mouse models, and suggests that the greatest impact of myostatin in the regulation of muscle mass may not be to induce atrophy directly, but rather to block hypertrophy signalling. PMID:25640143

  19. The anatomy and histology of the bicipital tunnel of the shoulder.

    PubMed

    Taylor, Samuel A; Fabricant, Peter D; Bansal, Manjula; Khair, M Michael; McLawhorn, Alexander; DiCarlo, Edward F; Shorey, Mary; O'Brien, Stephen J

    2015-04-01

    The bicipital tunnel is the extra-articular, fibro-osseous structure that encloses the long head of the biceps tendon. Twelve cadaveric shoulder specimens underwent in situ casting of the bicipital tunnel with methyl methacrylate cement to demonstrate structural competence (n = 6) and en bloc harvest with gross and histologic evaluation (n = 6). The percentage of empty tunnel was calculated histologically by subtracting the proportion of cross-sectional area of the long head of the biceps tendon from that of the bicipital tunnel for each zone. Cement casting demonstrated that the bicipital tunnel was a closed space. Zone 1 extended from the articular margin to the distal margin of the subscapularis tendon. Zone 2 extended from the distal margin of the subscapularis tendon to the proximal margin of the pectoralis major tendon. Zone 3 was the subpectoral region. Zones 1 and 2 were both enclosed by a dense connective tissue sheath and demonstrated the presence of synovium. Zone 3 had significantly greater percentage of empty tunnel than zones 1 and 2 did (P < .01). The bicipital tunnel is a closed space with 3 distinct zones. Zones 1 and 2 have similar features, including the presence of synovium, but differ from zone 3. A significant bottleneck occurs between zone 2 and zone 3, most likely at the proximal margin of the pectoralis major tendon. The bicipital tunnel is a closed space where space-occupying lesions may produce a bicipital tunnel syndrome. Careful consideration should be given to surgical techniques that decompress both zones 1 and 2 of the bicipital tunnel. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  20. Effect of eccentric training on the plantar flexor muscle-tendon tissue properties.

    PubMed

    Mahieu, Nele Nathalie; McNair, Peter; Cools, Ann; D'Haen, Caroline; Vandermeulen, Katrien; Witvrouw, Erik

    2008-01-01

    It has been shown that eccentric training can be effective in the rehabilitation of patients with Achilles tendonopathy. The mechanism behind these results is not clear. However, there is evidence that tendons are able to respond to repeated forces by altering their structure and composition, and, thus, their mechanical properties change. In this regard, the objective of the present study was to investigate whether eccentric training affects the mechanical properties of the plantar flexor's muscle-tendon tissue properties. Seventy-four healthy subjects were randomized into two groups: an eccentric training group and a control group. The eccentric training group performed a 6-wk eccentric training program for the calf muscles. Before and after this period, all subjects were evaluated for dorsiflexion range of motion using universal goniometry, passive resistive torque of the plantar flexors, and stiffness of the Achilles tendon. Passive resistive torque was measured during ankle dorsiflexion on an isokinetic dynamometer. Stiffness of the Achilles tendon was assessed using a dynamometer, in combination with ultrasonography. The results of the study reveal that the dorsiflexion range of motion was significantly increased only in the eccentric training group. The eccentric heel drop program also resulted in a significant decrease of the passive resistive torque of the plantar flexors (from 16.423 +/- 0.827 to 12.651 +/- 0.617 N.m). The stiffness of the Achilles tendon did not change significantly as a result of training. These findings provide evidence that an eccentric training program results in changes to some of the mechanical properties of the plantar flexor muscles. These changes were thought to be associated with modifications to structure rather than to stretch tolerance.

  1. Posterolateral complex knee injuries: magnetic resonance imaging with surgical correlation.

    PubMed

    Theodorou, D J; Theodorou, S J; Fithian, D C; Paxton, L; Garelick, D H; Resnick, D

    2005-05-01

    To describe the magnetic resonance imaging (MRI) findings of injuries of the posterolateral aspect of the knee and to evaluate the diagnostic capabilities of MRI in the assessment of these injuries. The MRI studies of 14 patients (mean age 33 years) with trauma to the posterolateral aspect of the knee were retrospectively reviewed, and the imaging findings were correlated with those of surgery. In all patients, MRI showed an intact iliotibial (ITB) band. MRI showed injury to the biceps tendon in 11 (79%), the gastrocnemius tendon in 1 (7%)), the popliteus tendon in 5 (36%), and the lateral collateral ligament (LCL) in 14 (100%) patients. Tear of the anterior cruciate ligament (ACL) was seen in 11 (79%) patients and tear of the posterior cruciate ligament (PCL) in 4 (29%) patients. With routine MRI, visualization of the popliteofibular or fabellofibular ligaments was incomplete. On MRI, the lateral meniscus and the medial meniscus were torn with equal frequency (n = 4; 29%). Osteochondral defects were seen in 5 (36%) cases and joint effusion in all 14 (100%) cases on MRI. Using surgical findings as the standard for diagnosis, MRI proved 86% accurate in the detection of injury to the ITB band, the biceps tendon (93%), the gastrocnemius tendon (100%), the popliteus tendon (86%), the LCL (100%), the ACL (79%), the PCL (86%), the lateral meniscus (90%), the medial meniscus (82%), and the osteochondral structures (79%). Surgical correlation confirmed the MRI findings of joint effusion in all cases. MRI is well suited for demonstrating the presence and extent of injuries of the major structures of the posterolateral complex of the knee, allowing characterization of the severity of injury.

  2. Hyaluronic acid injections protect patellar tendon from detraining-associated damage.

    PubMed

    Frizziero, Antonio; Salamanna, Francesca; Giavaresi, Gianluca; Ferrari, Andrea; Martini, Lucia; Marini, Marina; Veicsteinas, Arsenio; Maffulli, Nicola; Masiero, Stefano; Fini, Milena

    2015-09-01

    Having previously demonstrated that detraining affects patellar tendon (PT) proteoglycan content and collagen fiber organization, we undertook the present study with two aims: to improve knowledge on the adaptation of PT and its enthesis to detraining from a histological and histomorphometric point of view, and to investigate the hypothesis that repeated peri-patellar injections of hyaluronic acid (HA) on detrained PT may reduce and limit detrained associated-damage. Twenty-four male Sprague-Dawley rats were divided into 3 groups: Untrained (n=6), Trained (n=6) (10 wks-treadmill) and Detrained (n=12). In the detrained rats, the left tendon was untreated while the right tendon received repeated peri-patellar injections of either HA or saline (NaCl). Structure and morphology of PTs (modified Movin score, tear density, collagen type I and III) and enthesis (cell morphology, chondrocyte cluster formation, tidemark integrity, matrix staining and vascularization) were evaluated. The left PT and enthesis of the Detrained groups showed altered structure and morphology with the highest Movin score values, the highest percentage of collagen III and the lowest of collagen I; the lowest score values were observed in the Trained and Detrained-HA groups. Detrained-NaCl PTs showed the highest collagen III and the lowest collagen I values with respect to Detrained-HA PTs. This study strengthens previously published data showing the alteration in tendon and enthesis morphology due to discontinuation of training, and provides new data showing that treatment with HA is effective in the maintenance of the structural properties of PT and enthesis in Detrained rats. Such beneficial effects could play a significant role in the management of conservative and rehabilitation strategies in athletes that change type, intensity and duration of training.

  3. Probing multi-scale mechanical damage in connective tissues using X-ray diffraction.

    PubMed

    Bianchi, Fabio; Hofmann, Felix; Smith, Andrew J; Thompson, Mark S

    2016-11-01

    The accumulation of microstructural collagen damage following repetitive loading is linked to painful and debilitating tendon injuries. As a hierarchical, semi-crystalline material, collagen mechanics can be studied using X-ray diffraction. The aim of the study was to describe multi-structural changes in tendon collagen following controlled plastic damage (5% permanent strain). We used small angle X-ray scattering (SAXS) to interrogate the spacing of collagen molecules within a fibril, and wide angle X-ray scattering (WAXS) to measure molecular strains under macroscopic loading. Simultaneous recordings of SAXS and WAXS patterns, together with whole-tissue strain in physiologically hydrated rat-tail tendons were made during increments of in situ tensile loading. Results showed that while tissue level modulus was unchanged, fibril modulus decreased significantly, and molecular modulus significantly increased. Further, analysis of higher order SAXS peaks suggested structural changes in the gap and overlap regions, possibly localising the damage to molecular cross-links. Our results provide new insight into the fundamental damage processes at work in collagenous tissues and point to new directions for their mitigation and repair. This article reports the first in situ loading synchrotron studies on mechanical damage in collagenous tissues. We provide new insight into the nano- and micro-structural mechanisms of damage processes. Pre-damaged tendons showed differential alteration of moduli at macro, micro and nano-scales as measured using X-ray scattering techniques. Detailed analysis of higher order diffraction peaks suggested damage is localised to molecular cross-links. The results are consistent with previous X-ray scattering studies of tendons and also with recent thermal stability studies on damaged material. Detailed understanding of damage mechanisms is essential in the development of new therapies promoting tissue repair. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  4. Structural and functional assessment of intense therapeutic ultrasound effects on partial Achilles tendon transection

    NASA Astrophysics Data System (ADS)

    Barton, Jennifer K.; Rice, Photini S.; Howard, Caitlin C.; Koevary, Jen W.; Danford, Forest; Gonzales, David A.; Vande Geest, Jon; Latt, L. Daniel; Szivek, John A.; Amodei, Richard; Slayton, Michael

    2018-02-01

    Tendinopathies and tendon tears heal slowly because tendons have a limited blood supply. Intense therapeutic ultrasound (ITU) is a treatment modality that creates very small, focal coagula in tissue, which can stimulate a healing response. This pilot study investigated the effects of ITU on rabbit and rat models of partial Achilles tendon rupture. The right Achilles tendons of 20 New Zealand White rabbits and 118 rats were partially transected. Twenty-four hours after surgery, ITU coagula were placed in the tendon and surrounding tissue, alternating right and left legs. At various time points, the following data were collected: ultrasound imaging, optical coherence tomography (OCT) imaging, mechanical testing, gene expression analysis, histology, and multiphoton microscopy (MPM) of sectioned tissue. Ultrasound visualized cuts and treatment lesions. OCT showed the effect of the interventions on birefringence banding caused by collagen organization. MPM showed inflammatory infiltrate, collagen synthesis and organization. By day 14- 28, all tendons had a smooth appearance and histology, MPM and OCT still could still visualize residual healing processes. Few significant results in gene expression were seen, but trends were that ITU treatment caused an initial decrease in growth and collagen gene expression followed by an increase. No difference in failure loads was found between control, cut, and ITU treatment groups, suggesting that sufficient healing had occurred by 14 days to restore all test tissue to control mechanical properties. These results suggest that ITU does not cause harm to tendon tissue. Upregulation of some genes suggests that ITU may increase healing response.

  5. Ultrasound measures of tendon thickness: Intra-rater, Inter-rater and Inter-machine reliability.

    PubMed

    Del Baño-Aledo, María Elena; Martínez-Payá, Jacinto Javier; Ríos-Díaz, José; Mejías-Suárez, Silvia; Serrano-Carmona, Sergio; de Groot-Ferrando, Ana

    2017-01-01

    Ultrasound imaging is often used by physiotherapists and other healthcare professionals but the reliability of image acquisition with different ultrasound machines is unknown. The objective was to compare the intra-rater, inter-rater and intermachine reliability of thickness measurements of the plantar fascia (PF), Achilles tendon (AT), patellar tendon (PT) and elbow common extensor tendon (ECET) with musculoskeletal ultrasound imaging (MSUS). Tendon thickness was measured in four anatomical structures (14 participants, 28 images per tendon) by two sonographers and with two different ultrasound machines. Intraclass Correlation Coefficients (ICCs) and Bland-Altman plots were calculated. The standard error of measurement (SEM) and minimum detectable difference (MDD) were calculated. Inter-rater reliability was excellent for AT (ICC=0.98; 95% CI= 0.96-0.99) and very good for PT (ICC=0.85; 95% CI = 0.67-0.93) and ECET (ICC=0.81; 95% CI= 0.72-0.94). Reliability for PF was moderate, with an ICC of 0.63 (CI 95%= 0.20-0.83). Bland-Altman plot for inter-machine reliability showed a mean difference of 1 m for PF measurements and a mean difference of 4 m and 20 m for AT and PT. The relative SEMs were below 7% and the MDCs were below 0.7 mm. The MSUS reliability in measuring thickness of the four tendons is confirmed by the homogeneous readings intra sonographers, between operators and between different machines. Level of evidence: Tendon thickness can be measured reliably on different ultrasound devices, which is an important step forward in the use of this technique in daily clinical practice and research. III.

  6. Role of xenogenous bovine platelet gel embedded within collagen implant on tendon healing: an in vitro and in vivo study

    PubMed Central

    Oryan, Ahmad; Meimandi-Parizi, Abdolhamid; Maffulli, Nicola

    2015-01-01

    Surgical reconstruction of large Achilles tendon defects is demanding. Platelet concentrates may be useful to favor healing in such conditions. The characteristics of bovine platelet-gel embedded within a collagen-implant were determined in vitro, and its healing efficacy was examined in a large Achilles tendon defect in rabbits. Two cm of the left Achilles tendon of 60 rabbits were excised, and the animals were randomly assigned to control (no implant), collagen-implant, or bovine-platelet-gel-collagen-implant groups. The tendon edges were maintained aligned using a Kessler suture. No implant was inserted in the control group. In the two other groups, a collagen-implant or bovine-platelet-gel-collagen-implant was inserted in the defect. The bioelectricity and serum platelet-derived growth factor levels were measured weekly and at 60 days post injury, respectively. After euthanasia at 60 days post injury, the tendons were tested at macroscopic, microscopic, and ultrastructural levels, and their dry matter and biomechanical performances were also assessed. Another 60 rabbits were assigned to receive no implant, a collagen-implant, or a bovine-platelet-gel-collagen-implant, euthanized at 10, 20, 30, and 40 days post injury, and their tendons were evaluated grossly and histologically to determine host-graft interactions. Compared to the control and collagen-implant, treatment with bovine-platelet-gel-collagen-implant improved tissue bioelectricity and serum platelet-derived growth factor levels, and increased cell proliferation, differentiation, and maturation. It also increased number, diameter, and density of the collagen fibrils, alignment and maturation of the collagen fibrils and fibers, biomechanical properties and dry matter content of the injured tendons at 60 days post injury. The bovine-platelet-gel-collagen-implant also increased biodegradability, biocompatibility, and tissue incorporation behavior of the implant compared to the collagen-implant alone. This treatment also decreased tendon adhesion, muscle fibrosis, and atrophy, and improved the physical activity of the animals. The bovine-platelet-gel-collagen-implant was effective in neotenon formation in vivo, which may be valuable in the clinical setting. PMID:25341879

  7. Sports Injury-Related Fingers and Thumb Deformity Due to Tendon or Ligament Rupture.

    PubMed

    Bai, Rong-Jie; Zhang, Hui-Bo; Zhan, Hui-Li; Qian, Zhan-Hua; Wang, Nai-Li; Liu, Yue; Li, Wen-Ting; Yin, Yu-Ming

    2018-05-05

    Hand injuries are very common in sports, such as skiing and ball sports. One of the major reasons causing hand and finger deformity is due to ligament and tendon injury. The aim of this study was to investigate if the high-resolution 3T magnetic resonance imaging (MRI) can demonstrate the complex anatomy of the fingers and thumb, especially the tendons and ligaments, and provide the accurate diagnosis of clinically important fingers and thumbs deformity due to ligamentous and tendinous injuries during sport activities. Sixteen fresh un-embalmed cadaveric hands were harvested from eight cadavers. A total of 20 healthy volunteers' hands and 44 patients with fingers or thumb deformity due to sports-related injuries were included in this study. All subjects had MR examination with T1-weighted images and proton density-weighted imaging with fat suppression (PD FS) in axial, coronal, and sagittal plane, respectively. Subsequently, all 16 cadaveric hands were sliced into 2-mm thick slab with a band saw (six in coronal plane, six in sagittal plane, and four in axial plane). The correlation of anatomic sections and the MRI characteristics of tendons of fingers and the ulnar collateral ligament (UCL) at the metacarpal phalangeal joint (MCPJ) of thumb between 20 healthy volunteers and 44 patients (confirmed by surgery) were analyzed. The normal ligaments and tendons in 16 cadaveric hands and 20 volunteers' hands showed uniform low-signal intensity on all the sequences of the MRI. Among 44 patients with tendinous and ligamentous injuries in the fingers or thumb, 12 cases with UCL injury at MCPJ of the thumb (Stener lesion = 8 and non-Stener lesion = 4), 6 cases with the central slip injury, 12 cases with terminal tendon injury, and 14 cases with flexor digitorum profundus injury. The ligaments and tendons disruption manifested as increased signal intensity and poor definition, discontinuity, and heterogeneous signal intensity of the involved ligaments and tendons. Sports injury-related fingers and thumb deformity are relatively common. MRI is an accurate method for evaluation of the anatomy and pathologic conditions of the fingers and thumb. It is a useful tool for accurate diagnosis of the sports-related ligaments and tendons injuries in hand.

  8. Anabolic androgenic steroids reverse the beneficial effect of exercise on tendon biomechanics: an experimental study.

    PubMed

    Tsitsilonis, Serafim; Chatzistergos, Panayiotis E; Panayiotis, Chatzistergos E; Mitousoudis, Athanasios S; Athanasios, Mitousoudis S; Kourkoulis, Stavros K; Stavros, Kourkoulis K; Vlachos, Ioannis S; Ioannis, Vlachos S; Agrogiannis, George; George, Agrogiannis; Fasseas, Konstantinos; Konstantinos, Fasseas; Perrea, Despina N; Despina, Perrea N; Zoubos, Aristides B; Aristides, Zoubos B

    2014-06-01

    The effect of anabolic androgenic steroids on tendons has not yet been fully elucidated. Aim of the present study was the evaluation of the impact of anabolic androgenic steroids on the biomechanical and histological characteristics of Achilles tendons. Twenty-four male Wistar rats were randomized into four groups with exercise and anabolic steroids (nandrolone decanoate) serving as variables. Protocol duration was 12 weeks. Following euthanasia, tendons' biomechanical properties were tested with the use of a modified clamping configuration. Histological examination with light and electron microscopy were also performed. In the group of anabolic steroids and exercise the lowest fracture stress values were observed, while in the exercise group the highest ones. Histological examination by light and electron microscopy revealed areas of collagen dysplasia and an increased epitendon in the groups receiving anabolic steroids and exercise. These findings suggest that anabolic androgenic steroids reverse the beneficial effect of exercise, thus resulting in inferior maximal stress values. Copyright © 2013 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  9. Proteomic Analysis of Human Tendon and Ligament: Solubilization and Analysis of Insoluble Extracellular Matrix in Connective Tissues.

    PubMed

    Sato, Nori; Taniguchi, Takako; Goda, Yuichiro; Kosaka, Hirofumi; Higashino, Kosaku; Sakai, Toshinori; Katoh, Shinsuke; Yasui, Natsuo; Sairyo, Koichi; Taniguchi, Hisaaki

    2016-12-02

    Connective tissues such as tendon, ligament and cartilage are mostly composed of extracellular matrix (ECM). These tissues are insoluble, mainly due to the highly cross-linked ECM proteins such as collagens. Difficulties obtaining suitable samples for mass spectrometric analysis render the application of modern proteomic technologies difficult. Complete solubilization of them would not only elucidate protein composition of normal tissues but also reveal pathophysiology of pathological tissues. Here we report complete solubilization of human Achilles tendon and yellow ligament, which is achieved by chemical digestion combined with successive protease treatment including elastase. The digestion mixture was subjected to liquid chromatography-mass spectrometry. The low specificity of elastase was overcome by accurate mass analysis achieved using FT-ICR-MS. In addition to the detailed proteome of both tissues, we also quantitatively determine the major protein composition of samples, by measuring peak area of some characteristic peptides detected in tissue samples and in purified proteins. As a result, differences between human Achilles tendon and yellow ligament were elucidated at molecular level.

  10. Etiology and pathophysiology of tendon ruptures in sports.

    PubMed

    Kannus, P; Natri, A

    1997-04-01

    Of all spontaneous tendon ruptures, complete Achilles tendon tears are most closely associated with sports activities (1-3). Schönbauer (3) reported that 75% of all ruptures of the Achilles tendon are related to sports. In Plecko & Passl (2) the number was 60%. In our material of 430 cases, the number of sports-related Achilles ruptures was very similar (62%), while only 2% of ruptures of other tendons were sports-related (P < 0.001) (1). Also, the majority of Achilles reruptures occurred in sports. The ruptures occurred most often in soccer (34%), track and field (16%) and basketball (14%). The distribution of Achilles ruptures according to different sports varies considerably from country to country, according to the national sport traditions. For example, in northern and middle Europe, soccer, tennis, track and field, indoor ball games, downhill skiing, and gymnastics are the most common; and in North America, football, basketball, baseball, tennis and downhill skiing dominate the statistics (1, 2, 4). In sports, some Achilles ruptures are not spontaneous or degeneration-induced but may occur as a consequence of the remarkably high forces that are involved in the performance (2). Ruptures in the high jump or triple jump are good examples. In such cases, failure in the neuromuscular protective mechanisms due to fatigue or disturbed co-ordination can frequently be found. The spontaneous complete rupture of the supraspinatus tendon of the rotator cuff does not occur very frequently in sports. Those sports that include high-energy throwing movements, such as American and Finnish baseball, American football, rugby and discuss and javelin throwing, may, however, produce this injury. Partial tears and inflammations of the rotator cuff complex are much more frequent in throwing sports. The complete rupture of the proximal long head of the biceps brachii tendon is rare among competitive and recreational athletes. In our material, under 2% of these ruptures were associated with sports activities (5). The rupture (avulsion) of the distal tendon of the biceps muscle is rare. In sports, gymnastics, body building and weight lifting have been said to be able to produce this injury (6). In general, complete ruptures of the quadriceps tendon and the patellar tendon occur most often in older individuals. In our study, the mean age of these patients was 65 years (5). However, these injuries do also occur in younger age groups, especially in athletes. In athletes, the rupture most frequently occurs in high-power sports events, such as high jump, basketball and weight lifting, at the age of 15-30 years. A chronic-patellar apicitis (jumper's knee) may predispose rupture of the tendon (7). As is the case with the rotator cuff complex, overuse inflammation and partial tears of the quadriceps and patellar tendons are one of the most characteristic athletic injuries. Complete spontaneous ruptures of other tendons in sports are rare, although the literature does provide case studies from almost every tendon the human body possesses (8-18).

  11. Clinical follow-up of horses treated with allogeneic equine mesenchymal stem cells derived from umbilical cord blood for different tendon and ligament disorders.

    PubMed

    Van Loon, Vic J F; Scheffer, Carmen J W; Genn, Herman J; Hoogendoorn, Arie C; Greve, Jan W

    2014-01-01

    Mesenchymal stem cells (MSCs) offer promise as therapeutic aids in the repair of tendon and ligament disorders in sport horses. Equine allogeneic MSCs derived from umbilical cord blood (eUCB-MSCs) can be obtained in a minimally invasive fashion with successful propagation of MSCs. The objective of this study was to determine the applicability and therapeutic effect of eUCB-MSCs on tendinitis of the superficial digital flexor tendon, desmitis of the suspensory ligament, tendinitis of the deep digital flexor tendon, and desmitis of the inferior check ligament in clinical cases. A retrospective clinical study was performed. At two equine clinics, 52 warmblood horses were treated with cultured eUCB-MSCs between 2009 and 2012. About 2-10 × 10(6) cells per lesion were administered. When a lesion was treated twice, the total amount could run up to 20 × 10(6) cells. Pearson's chi-squared test was used to compare the effect of the injured structure on the success rate, as well as the effect of the age of the horse. Based on repeated examinations, 40 horses (77%) returned to work on the same or a higher level based on information provided by the owner. Neither the injured structure nor the age of the horse had a statistically significant influence on the result. Overall, the results of treatment of some tendon and ligament injuries with eUCB-MSCs in clinical cases are promising.

  12. Morphologic Characteristics and Strength of the Hamstring Muscles Remain Altered at 2 Years After Use of a Hamstring Tendon Graft in Anterior Cruciate Ligament Reconstruction.

    PubMed

    Konrath, Jason M; Vertullo, Christopher J; Kennedy, Ben A; Bush, Hamish S; Barrett, Rod S; Lloyd, David G

    2016-10-01

    The hamstring tendon graft used in anterior cruciate ligament (ACL) reconstruction has been shown to lead to changes to the semitendinosus and gracilis musculature. We hypothesized that (1) loss of donor muscle size would significantly correlate with knee muscle strength deficits, (2) loss of donor muscle size would be greater for muscles that do not experience tendon regeneration, and (3) morphological adaptations would also be evident in nondonor knee muscles. Cross-sectional study; Level of evidence, 3. Twenty participants (14 men and 6 women, mean age 29 ± 7 years, mean body mass 82 ± 15 kg) who had undergone an ACL reconstruction with a hamstring tendon graft at least 2 years previously underwent bilateral magnetic resonance imaging and subsequent strength testing. Muscle and tendon volumes, peak cross-sectional areas (CSAs), and lengths were determined for 12 muscles and 6 functional muscle groups of the surgical and contralateral limbs. Peak isokinetic concentric strength was measured in knee flexion/extension and internal/external tibial rotation. Only 35% of the patients showed regeneration of both the semitendinosus and gracilis tendons. The regenerated tendons were longer with larger volume and CSA compared with the contralateral side. Deficits in semitendinosus and gracilis muscle size were greater for muscles in which tendons did not regenerate. In addition, combined hamstring muscles (semitendinosus, semimembranosus, and biceps femoris) and combined medial knee muscles (semitendinosus, semimembranosus, gracilis, vastus medialis, medial gastrocnemius, and sartorius) on the surgical side were reduced in volume by 12% and 10%, respectively. A 7% larger volume was observed in the surgical limb for the biceps femoris muscle and corresponded with a lower internal/external tibial rotation strength ratio. The difference in volume, peak CSA, and length of the semitendinosus and gracilis correlated significantly with the deficit in knee flexion strength, with Pearson correlations of 0.51, 0.57, and 0.61, respectively. The muscle-tendon properties of the semitendinosus and gracilis are substantially altered after harvesting, and these alterations may contribute to knee flexor weakness in the surgical limb. These deficits are more pronounced in knees with tendons that do not regenerate and are only partially offset by compensatory hypertrophy of other hamstring muscles. © 2016 The Author(s).

  13. Ultrasonographic evaluation of the canine shoulder.

    PubMed

    Long, C D; Nyland, T G

    1999-01-01

    The aim of this study was to determine the normal ultrasonographic anatomy of the canine shoulder. Fourteen shoulders from 7 clinically normal mid-sized dogs were radiographed and imaged using high frequency ultrasound. Each shoulder was isolated postmortem, and the ultrasonographic and gross anatomy was studied during dissection. The ultrasonographic appearance of the shoulder specimens was similar to that found in the live dogs. Twenty-four shoulders isolated postmortem from 12 variably sized dogs were also used to characterize the normal ultrasound anatomy over a range of sizes. Important anatomic structures that could be consistently evaluated were the biceps tendon and bursa, the bicipital groove surface, the supraspinatous tendon, the infraspinatous tendon, the teres minor tendon, and the caudal aspect of the humeral head. Results of ultrasonographic examination of 4 dogs with shoulder lameness are described to illustrate some applications of canine shoulder ultrasonography in the evaluation of the canine shoulder. In these dogs, ultrasound was a valuable tool to evaluate effusion and synovial proliferation within the bicipital bursa, supraspinatous and biceps tendinitis, biceps tendon strain, and dystrophic calcification.

  14. The Improvement of Bone-Tendon Fixation by Porous Titanium Interference Screw: A Rabbit Animal Model.

    PubMed

    Tsai, Pei-I; Chen, Chih-Yu; Huang, Shu-Wei; Yang, Kuo-Yi; Lin, Tzu-Hung; Chen, San-Yuan; Sun, Jui-Sheng

    2018-05-04

    The interference screw is a widely used fixation device in the anterior cruciate ligament (ACL) reconstruction surgeries. Despite the generally satisfactory results, problems of using interference screws were reported. By using additive manufacturing (AM) technology, we developed an innovative titanium alloy (Ti 6 Al 4 V) interference screw with rough surface and inter-connected porous structure designs to improve the bone-tendon fixation. An innovative Ti 6 Al 4 V interference screws were manufactured by AM technology. In vitro mechanical tests were performed to validate its mechanical properties. Twenty-seven New Zealand white rabbits were randomly divided into control and AM screw groups for biomechanical analyses and histological analysis at 4, 8 and 12 weeks postoperatively; while micro-CT analysis was performed at 12 weeks postoperatively. The biomechanical tests showed that the ultimate failure load in the AM interference screw group was significantly higher than that in the control group at all tested periods. These results were also compatible with the findings of micro-CT and histological analyses. In micro-CT analysis, the bone-screw gap was larger in the control group; while for the additive manufactured screw, the screw and bone growth was in close contact. In histological study, the bone-screw gaps were wider in the control group and were almost invisible in the AM screw group. The innovative AM interference screws with surface roughness and inter-connected porous architectures demonstrated better bone-tendon-implant integration, and resulted in stronger biomechanical characteristics when compared to traditional screws. These advantages can be transferred to future interference screw designs to improve their clinical performance. The AM interference screw could improve graft fixation and eventually result in better biomechanical performance of the bone-tendon-screw construct. The innovative AM interference screws can be transferred to future interference screw designs to improve the performance of implants. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  15. Multiscale mechanical integrity of human supraspinatus tendon in shear after elastin depletion.

    PubMed

    Fang, Fei; Lake, Spencer P

    2016-10-01

    Human supraspinatus tendon (SST) exhibits region-specific nonlinear mechanical properties under tension, which have been attributed to its complex multiaxial physiological loading environment. However, the mechanical response and underlying multiscale mechanism regulating SST behavior under other loading scenarios are poorly understood. Furthermore, little is known about the contribution of elastin to tendon mechanics. We hypothesized that (1) SST exhibits region-specific shear mechanical properties, (2) fiber sliding is the predominant mode of local matrix deformation in SST in shear, and (3) elastin helps maintain SST mechanical integrity by facilitating force transfer among collagen fibers. Through the use of biomechanical testing and multiphoton microscopy, we measured the multiscale mechanical behavior of human SST in shear before and after elastase treatment. Three distinct SST regions showed similar stresses and microscale deformation. Collagen fiber reorganization and sliding were physical mechanisms observed as the SST response to shear loading. Measures of microscale deformation were highly variable, likely due to a high degree of extracellular matrix heterogeneity. After elastase treatment, tendon exhibited significantly decreased stresses under shear loading, particularly at low strains. These results show that elastin contributes to tendon mechanics in shear, further complementing our understanding of multiscale tendon structure-function relationships. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Effects of in vivo applications of peripheral blood-derived mesenchymal stromal cells (PB-MSCs) and platlet-rich plasma (PRP) on experimentally injured deep digital flexor tendons of sheep.

    PubMed

    Martinello, Tiziana; Bronzini, Ilaria; Perazzi, Anna; Testoni, Stefania; De Benedictis, Gulia Maria; Negro, Alessandro; Caporale, Giovanni; Mascarello, Francesco; Iacopetti, Ilaria; Patruno, Marco

    2013-02-01

    Tendon injuries, degenerative tendinopathies, and overuse tendinitis are common in races horses. Novel therapies aim to restore tendon functionality by means of cell-based therapy, growth factor delivery, and tissue engineering approaches. This study examined the use of autologous mesenchymal stromal cells derived from peripheral blood (PB-MSCs), platelet-rich plasma (PRP) and a combination of both for ameliorating experimental lesions on deep digital flexor tendons (DDFT) of Bergamasca sheep. In particular, testing the combination of blood-derived MSCs and PRP in an experimental animal model represents one of the few studies exploring a putative synergistic action of these treatments. Effectiveness of treatments was evaluated at 30 and 120 days comparing clinical, ultrasonographic, and histological features together with immunohistochemical expression of collagen types 1 and 3, and cartilage oligomeric matrix protein (COMP). Significant differences were found between treated groups and their corresponding controls (placebo) regarding tendon morphology and extracellular matrix (ECM) composition. However, our results indicate that the combined use of PRP and MSCs did not produce an additive or synergistic regenerative response and highlighted the predominant effect of MSCs on tendon healing, enhanced tissue remodeling and improved structural organization. Copyright © 2012 Orthopaedic Research Society.

  17. The effects of chronic unloading and gap formation on tendon-to-bone healing in a rat model of massive rotator cuff tears

    PubMed Central

    Killian, Megan L.; Cavinatto, Leonardo; Shah, Shivam A.; Sato, Eugene J.; Ward, Samuel R.; Havlioglu, Necat; Galatz, Leesa M.; Thomopoulos, Stavros

    2014-01-01

    The objective of this study was to understand the effect of pre-repair rotator cuff chronicity on post-repair healing outcomes using a chronic and acute multi-tendon rat rotator cuff injury model. Full-thickness dual tendon injuries (supra- and infraspinatus) were created unilaterally in adult male Sprague Dawley rats, and left chronically detached for 8 or 16 weeks. After chronic detachment, tears were repaired and acute dual tendon injuries were created and immediately repaired on contralateral shoulders. Tissue level outcomes for bone, tendon, and muscle were assessed 4 or 8 weeks after repair using histology, microcomputed tomography, biomechanical testing, and biochemical assays. Substantial gap formation was seen in 35% of acute repairs and 44% of chronic repairs. Gap formation negatively correlated with mechanical and structural outcomes for both healing time points regardless of injury duration. Bone and histomorphometry, as well as biomechanics, were similar between acute and chronic injury and repair regardless of chronicity and duration of healing. This study was the first to implement a multi-tendon rotator cuff injury with surgical repair following both chronic and acute injuries. Massive tear in a rodent model resulted in gap formation regardless of injury duration which had detrimental effects on repair outcomes. PMID:24243733

  18. Tendinopathy: injury, repair, and current exploration

    PubMed Central

    Lipman, Kelsey; Wang, Chenchao; Ting, Kang; Soo, Chia; Zheng, Zhong

    2018-01-01

    Both acute and chronic tendinopathy result in high morbidity, requiring management that is often lengthy and expensive. However, limited and conflicting scientific evidence surrounding current management options has presented a challenge when trying to identify the best treatment for tendinopathy. As a result of shortcomings of current treatments, response to available therapies is often poor, resulting in frustration in both patients and physicians. Due to a lack of understanding of basic tendon-cell biology, further scientific investigation is needed in the field for the development of biological solutions. Optimization of new delivery systems and therapies that spatially and temporally mimic normal tendon physiology hold promise for clinical application. This review focuses on the clinical importance of tendinopathy, the structure of healthy tendons, tendon injury, and healing, and a discussion of current approaches for treatment that highlight the need for the development of new nonsurgical interventions. PMID:29593382

  19. Development of high shrinkage polyethylene terephthalate (PET) shape memory polymer tendons for concrete crack closure

    NASA Astrophysics Data System (ADS)

    Teall, Oliver; Pilegis, Martins; Sweeney, John; Gough, Tim; Thompson, Glen; Jefferson, Anthony; Lark, Robert; Gardner, Diane

    2017-04-01

    The shrinkage force exerted by restrained shape memory polymers (SMPs) can potentially be used to close cracks in structural concrete. This paper describes the physical processing and experimental work undertaken to develop high shrinkage die-drawn polyethylene terephthalate (PET) SMP tendons for use within a crack closure system. The extrusion and die-drawing procedure used to manufacture a series of PET tendon samples is described. The results from a set of restrained shrinkage tests, undertaken at differing activation temperatures, are also presented along with the mechanical properties of the most promising samples. The stress developed within the tendons is found to be related to the activation temperature, the cross-sectional area and to the draw rate used during manufacture. Comparisons with commercially-available PET strip samples used in previous research are made, demonstrating an increase in restrained shrinkage stress by a factor of two for manufactured PET filament samples.

  20. Effect of the Interposition of Calcium Phosphate Materials on Tendon-Bone Healing During Repair of Chronic Rotator Cuff Tear.

    PubMed

    Zhao, Song; Peng, Lingjie; Xie, Guoming; Li, Dingfeng; Zhao, Jinzhong; Ning, Congqin

    2014-08-01

    The current nature of tendon-bone healing after rotator cuff (RC) repair is still the formation of granulation tissue at the tendon-bone interface rather than the formation of fibrocartilage, which is the crucial structure in native tendon insertion and can be observed after knee ligament reconstruction. The interposition of calcium phosphate materials has been found to be able to enhance tendon-bone healing in knee ligament reconstruction. However, whether the interposition of these kinds of materials can enhance tendon-bone healing or even change the current nature of tendon-bone healing after RC repair still needs to be explored. The interposition of calcium phosphate materials during RC repair would enhance tendon-bone healing or change its current nature of granulation tissue formation into a more favorable process. Controlled laboratory study. A total of 144 male Sprague-Dawley rats underwent unilateral detachment of the supraspinatus tendon, followed by delayed repair after 3 weeks. The animals were allocated into 1 of 3 groups: (1) repair alone, (2) repair with Ca5(PO4)2SiO4 (CPS) bioceramic interposition, or (3) repair with hydroxyapatite (HA) bioceramic interposition at the tendon-bone interface. Animals were sacrificed at 2, 4, or 8 weeks postoperatively, and microcomputed tomography (micro-CT) was used to quantify the new bone formation at the repair site. New fibrocartilage formation and collagen organization at the tendon-bone interface was evaluated by histomorphometric analysis. Biomechanical testing of the supraspinatus tendon-bone complex was performed. Statistical analysis was performed using 1-way analysis of variance. Significance was set at P < .05. The micro-CT analysis demonstrated remarkable osteogenic activity and osteoconductivity to promote new bone formation and ingrowth of CPS and HA bioceramic, with CPS bioceramic showing better results than HA. Histological observations indicated that CPS bioceramic had excellent biocompatibility and biodegradability. At early time points after the RC repair, CPS bioceramic significantly increased the area of fibrocartilage at the tendon-bone interface compared with the control and HA groups. Moreover, CPS and HA bioceramics had significantly improved collagen organization. Biomechanical tests indicated that the CPS and HA groups have greater ultimate load to failure and stiffness than the control group at 4 and 8 weeks, and the CPS specimens exhibited the maximum ultimate load to failure, stiffness, and stress of the healing enthesis. Both CPS and HA bioceramics aid in cell attachment and proliferation and accelerate new bone formation, and CPS bioceramic has a more prominent effect on tendon-to-bone healing. Local application of CPS and HA bioceramic at the tendon-bone interface shows promise in improving healing after rotator cuff tear repair. © 2014 The Author(s).

  1. Achilles or biceps tendon rupture in women and men with type 2 diabetes: A population-based case-control study.

    PubMed

    Spoendlin, Julia; Meier, Christian; Jick, Susan S; Meier, Christoph R

    2016-07-01

    Previous studies suggest that diabetes causes alterations in tendon collagen structure, but evidence on how such findings translate into clinical practice is scarce. We aimed to analyze the association between type 2 diabetes and the risk of tendon rupture. We conducted a matched case-control analysis using the UK-based Clinical Practice Research Datalink. Cases (n=7895) were aged 30-89years and had an incident diagnosis of Achilles- or biceps tendon rupture between 1995 and 2013. In multivariable logistic regression analyses we compared the odds of tendon rupture between patients with or without type 2 diabetes, in men and women separately, and taking into account diabetes severity (HbA1c), duration, and antidiabetic drug treatment. Within 165 (7.1%) female cases with type 2 diabetes, odds ratios (ORs) were increased with poorer diabetes control (OR 2.03, 95% CI 1.20-3.41, HbA1c ≥9% [≥75mmol/mol]), longer disease duration (OR 1.60, 95% CI 0.93-2.74, ≥10years), and current insulin use (OR 2.25, 95% CI 1.30-3.90, ≥20 prescriptions). Among 372 (6.7%) male cases, there was no effect of type 2 diabetes on the risk of tendon rupture. Our results suggest that the risk of tendon ruptures may be increased in women with poorly controlled type 2 diabetes, but not in men. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Human adipose tissue-derived tenomodulin positive subpopulation of stem cells: A promising source of tendon progenitor cells.

    PubMed

    Gonçalves, A I; Gershovich, P M; Rodrigues, M T; Reis, R L; Gomes, M E

    2018-03-01

    Cell-based therapies are of particular interest for tendon and ligament regeneration given the low regenerative potential of these tissues. Adipose tissue is an abundant source of stem cells, which may be employed for the healing of tendon lesions. However, human adult multipotent adipose-derived stem cells (hASCs) isolated from the stromal vascular fraction of adipose tissue originate highly heterogeneous cell populations that hinder their use in specific tissue-oriented applications. In this study, distinct subpopulations of hASCs were immunomagnetic separated and their tenogenic differentiation capacity evaluated in the presence of several growth factors (GFs), namely endothelial GF, basic-fibroblast GF, transforming GF-β1 and platelet-derived GF-BB, which are well-known regulators of tendon development, growth and healing. Among the screened hASCs subpopulations, tenomodulin-positive cells were shown to be more promising for tenogenic applications and therefore this subpopulation was further studied, assessing tendon-related markers (scleraxis, tenomodulin, tenascin C and decorin) both at gene and protein level. Additionally, the ability for depositing collagen type I and III forming extracellular matrix structures were weekly assessed up to 28 days. The results obtained indicated that tenomodulin-positive cells exhibit phenotypical features of tendon progenitor cells and can be biochemically induced towards tenogenic lineage, demonstrating that this subset of hASCs can provide a reliable source of progenitor cells for therapies targeting tendon regeneration. Copyright © 2017 John Wiley & Sons, Ltd.

  3. Teaching enthesis ultrasound: experience of an ultrasound training workshop.

    PubMed

    Miguel, Cláudia; De Miguel, Eugenio; Batlle-Gualda, Enrique; Rejón, Eduardo; Lojo, Leticia

    2012-12-01

    To evaluate a standardised enthesis ultrasound training method, a workshop was conducted to train rheumatologists on enthesis ultrasound. After a theoretical session about ultrasound elementary enthesis lesions (changes in tendon architecture/thickness, bone proliferation/erosion, bursitis or Doppler signal), a reading exercise of 28 entheses' ultrasonographic images (plantar fasciae, Achilles, origin and insertion of patellar tendon) was completed. Participants scored through an electronic multiple-choice device with six possible lesions in each enthesis. To assess the adequacy and efficacy of the workshop, we explored the following: (1) subjective outcomes: a 12-item structured satisfaction questionnaire (graded 1-5 using Likert scale) and (2) objective outcomes of reliability: sensitivity (Se), specificity (Sp) and percentage of correctly classified cases (CC). Forty-nine participants attended the workshop. The satisfaction questionnaire demonstrated a 4.7 mean global value. The inter-reader Kappa reliability coefficient was moderate for the plantar fascia (0.47), Achilles tendon (0.47), and distal patellar tendons (0.50) and good for the proximal patellar tendon (0.63). The whole group means comparing to teachers' consensus were as follows: (a) plantar fascia: Se, 73.2%; Sp, 87.7%; CC, 83.3%; (b) Achilles: Se, 66.9%; Sp, 85.0%; CC, 79.5%; (c) distal patellar tendon: Se, 74.6%; Sp, 85.3%; CC, 82.1%; and (d) proximal patellar tendon: Se, 82.2%; Sp, 90.6%; CC, 88%. The proposed learning method seemed to be simple, easily performed, effective and well accepted by the target audience.

  4. Advanced age diminishes tendon-to-bone healing in a rat model of rotator cuff repair.

    PubMed

    Plate, Johannes F; Brown, Philip J; Walters, Jordan; Clark, John A; Smith, Thomas L; Freehill, Michael T; Tuohy, Christopher J; Stitzel, Joel D; Mannava, Sandeep

    2014-04-01

    Advanced patient age is associated with recurrent tearing and failure of rotator cuff repairs clinically; however, basic science studies have not evaluated the influence of aging on tendon-to-bone healing after rotator cuff repair in an animal model. Hypothesis/ This study examined the effect of aging on tendon-to-bone healing in an established rat model of rotator cuff repair using the aged animal colony from the National Institute on Aging of the National Institutes of Health. The authors hypothesized that normal aging decreases biomechanical strength and histologic organization at the tendon-to-bone junction after acute repair. Controlled laboratory study. In 56 F344xBN rats, 28 old and 28 young (24 and 8 months of age, respectively), the supraspinatus tendon was transected and repaired. At 2 or 8 weeks after surgery, shoulder specimens underwent biomechanical testing to compare load-to-failure and load-relaxation response between age groups. Histologic sections of the tendon-to-bone interface were assessed with hematoxylin and eosin staining, and collagen fiber organization was assessed by semiquantitative analysis of picrosirius red birefringence under polarized light. Peak failure load was similar between young and old animals at 2 weeks after repair (31% vs 26% of age-matched uninjured controls, respectively; P > .05) but significantly higher in young animals compared with old animals 8 weeks after repair (86% vs 65% of age-matched uninjured controls, respectively; P < .01). Eight weeks after repair, fibroblasts appeared more organized and uniformly aligned in young animals on hematoxylin and eosin slides compared with old animals. Collagen birefringence analysis of the tendon-to-bone junction demonstrated that young animals had increased collagen fiber organization and similar histologic structure compared with age-matched controls (53.7 ± 2.4 gray scales; P > .05). In contrast, old animals had decreased collagen fiber organization and altered structure compared with age-matched controls (49.8 ± 3.1 gray scales; P < .01). In a rat model of aging, old animals demonstrated diminished tendon-to-bone healing after rotator cuff injury and repair. Old animals had significantly decreased failure strength and collagen fiber organization at the tendon-to-bone junction compared with young animals. This study implies that animal age may need to be considered in future studies of rotator cuff repair in animal models. With increasing age and activity level of the population, the incidence of rotator cuff tears is predicted to rise. Despite advances in rotator cuff repair technique, the retear rate remains specifically high in elderly patients. The findings of this research suggest that aging negatively influences tendon-to-bone healing after rotator cuff repair in a validated animal model.

  5. Structure, ontogeny and evolution of the patellar tendon in emus (Dromaius novaehollandiae) and other palaeognath birds

    PubMed Central

    Pitsillides, Andrew A.; Hutchinson, John R.

    2014-01-01

    The patella (kneecap) exhibits multiple evolutionary origins in birds, mammals, and lizards, and is thought to increase the mechanical advantage of the knee extensor muscles. Despite appreciable interest in the specialized anatomy and locomotion of palaeognathous birds (ratites and relatives), the structure, ontogeny and evolution of the patella in these species remains poorly characterized. Within Palaeognathae, the patella has been reported to be either present, absent, or fused with other bones, but it is unclear how much of this variation is real, erroneous or ontogenetic. Clarification of the patella’s form in palaeognaths would provide insight into the early evolution of the patella in birds, in addition to the specialized locomotion of these species. Findings would also provide new character data of use in resolving the controversial evolutionary relationships of palaeognaths. In this study, we examined the gross and histological anatomy of the emu patellar tendon across several age groups from five weeks to 18 months. We combined these results with our observations and those of others regarding the patella in palaeognaths and their outgroups (both extant and extinct), to reconstruct the evolution of the patella in birds. We found no evidence of an ossified patella in emus, but noted its tendon to have a highly unusual morphology comprising large volumes of adipose tissue contained within a collagenous meshwork. The emu patellar tendon also included increasing amounts of a cartilage-like tissue throughout ontogeny. We speculate that the unusual morphology of the patellar tendon in emus results from assimilation of a peri-articular fat pad, and metaplastic formation of cartilage, both potentially as adaptations to increasing tendon load. We corroborate previous observations of a ‘double patella’ in ostriches, but in contrast to some assertions, we find independent (i.e., unfused) ossified patellae in kiwis and tinamous. Our reconstructions suggest a single evolutionary origin of the patella in birds and that the ancestral patella is likely to have been a composite structure comprising a small ossified portion, lost by some species (e.g., emus, moa) but expanded in others (e.g., ostriches). PMID:25551026

  6. Effects of different duration isometric contractions on tendon elasticity in human quadriceps muscles

    PubMed Central

    Kubo, Keitaro; Kanehisa, Hiroaki; Fukunaga, Tetsuo

    2001-01-01

    The present study aimed to investigate the influence of isometric training protocols with long- and short-duration contractions on the elasticity of human tendon structures in vivo. The elasticity was assessed through in vivo determination of the elongation (L) of the tendons and aponeuroses using ultrasonography, while the subjects performed ramp isometric exercise up to maximum voluntary contraction (MVC).Eight young males completed 12 weeks (4 days per week) of a unilateral isometric training programme on knee extensors, which consisted of two different combinations of contraction and relaxation times at 70 % MVC: one leg was trained using a short-duration protocol (3 sets of 50 repetitions of contraction for 1 s and relaxation for 2 s), and the other leg was trained using a long-duration protocol (4 sets of a combination of contraction for 20 s and relaxation for 1 min). The training volume per session, expressed as the integrated torque, was the same for the two protocols.Both protocols resulted in a significant increase in MVC: 31.8 ± 17.2 % for the short-duration protocol and 33.9 ± 14.4 % for the long-duration protocol. Moreover, the training produced significant increases in the muscle volume of the constituents of the quadriceps femoris, with similar relative gains for the two protocols: 7.4 ± 3.9 % for the short-duration protocol and 7.6 ± 4.3 % for the long-duration protocol.The short-duration protocol produced no significant change in L values at any of the force production levels. For the long-duration protocol, however, the L values above 550 N were significantly shorter after training. Analysis revealed that the group × test time interaction effect on tendon stiffness was significant. Stiffness increased significantly for the long-duration protocol, but not for the short-duration protocol.The present study demonstrates a greater increase in stiffness of human tendon structures following isometric training using longer duration contractions compared to shorter contractions. This suggests that the changes in the elasticity of the tendon structures after resistance training may be affected by the duration of muscle contraction. PMID:11600697

  7. Open versus percutaneous repair in the treatment of acute Achilles tendon rupture: a randomized prospective study.

    PubMed

    Gigante, A; Moschini, A; Verdenelli, A; Del Torto, M; Ulisse, S; de Palma, L

    2008-02-01

    There is no agreement on the ideal type of surgical management for Achilles tendon rupture. The present randomized prospective study was performed to compare outcome data of open and percutaneous repair in the treatment of Achilles tendon rupture. Forty consecutive patients with acute rupture of Achilles tendon were recruited. Patients were randomized to receive open (group A) or percutaneous repair with Tenolig (group B). All patients followed the same rehabilitation protocol except for slight differences in the duration of immobilization. Follow-up included objective evaluation (at 4 and 12 months), subjective evaluation using the SF-12 questionnaire (at 24 months), and bilateral ultrasound scanning and isokinetic testing (at 12 months). The differences in the parameters evaluated clinically were not significant except for ankle circumference, which was significantly greater in group B. There were two minor complications in the open repair group and one case of failed repair in the percutaneous group. SF-12 questionnaire, ultrasound and isokinetic test data did not show significant differences between the groups. The present study demonstrates that the open and the percutaneous technique are both safe and effective in repairing the ruptured Achilles tendon and that both afford the same degree of restoration of clinical, ultrasound and isokinetic patterns. Medium-term results were substantially comparable. Percutaneous repair is performed on a day-surgery basis, it reduces cutaneous complications and operation times, and enables faster recovery, enhancing overall patient compliance. To us, these characteristics make it preferable to open repair in managing subcutaneous ruptures of Achilles tendon in non-professional sports practicing adults.

  8. Tensile properties of a morphologically split supraspinatus tendon.

    PubMed

    Matsuhashi, Tomoya; Hooke, Alexander W; Zhao, Kristin D; Goto, Akira; Sperling, John W; Steinmann, Scott P; An, Kai-Nan

    2014-07-01

    The supraspinatus tendon consists morphologically of two sub-regions, anterior and posterior. The anterior sub-region is thick and tubular while the posterior is thin and strap-like. The purpose of this study was to compare the structural and mechanical properties of the anterior and posterior sub-regions of the supraspinatus tendon. The supraspinatus tendons from seven human cadaveric shoulders were morphologically divided into the anterior and posterior sub-regions. Length, width, and thickness were measured. A servo-hydraulic testing machine (MTS Systems Corporation, Minneapolis, MN) was used for tensile testing. The maximal load at failure, modulus of elasticity and ultimate tendon stress were calculated. Repeated measures were used for statistical comparisons. The mean anterior tendon cross-sectional area was 47.3 mm(2) and the posterior was 32.1 mm(2) . Failure occurred most often at the insertion site: anterior (5/7) and posterior (6/7). All parameters of the anterior sub-region were significantly greater than those of the posterior sub-region. The moduli of elasticity at the insertion site were 592.4 MPa in the anterior sub-region and 217.7 MPa in the posterior (P = 0.01). The ultimate failure loads were 779.2 N in the anterior sub-region and 335.6 N in the posterior (P = 0.003). The ultimate stresses were 22.1 MPa in the anterior sub-region and 11.6 MPa in the posterior (P = 0.008). We recognized that the anterior and posterior sub-regions of the SSP tendon have significantly different mechanical properties. In a future study, we need to evaluate how best to repair an SSP tendon considering these region-specific properties. Copyright © 2013 Wiley Periodicals, Inc.

  9. Sonoanatomic Variation of Pes Anserine Bursa

    PubMed Central

    Imani, Farnad; Abolhasan Gharehdag, Farid; Faiz, Seyed Hamid Reza

    2013-01-01

    Background The pes anserine bursa lies beneath the pes anserine tendon, which is the insertional tendon of the sartorius, gracilis, and semitendinosus muscles on the medial side of the tibia, but it can lie in different sites in the medial knee. Accurate diagnosis of the position of the bursa is critical for diagnostic and therapeutic goals. The aim of this study was to evaluate sonoanatomic variations of the pes anserine bursa in the medial knee. Methods One hundred seventy asymptomatic volunteers were enrolled in this study. Using ultrasound imaging (transverse approach, 7-13 MHz linear array probe) the sonoanatomic position of the pes anserine bursa and its relation to the pes anserine tendon were evaluated. Additionally, we evaluated the sonoanatomic variation of the saphenous nerve. Results The position of the pes anserine bursa was between the medial collateral ligament and the pes anserine tendons in 21.2%/18.8% (males/females) of subjects; between the pes anserine tendons and the tibia in 67.1%/64.7% (m/f); and among the pes anserine tendons in 8.2%/12.9% (m/f). No significant differences in the position of the bursa existed between males and females. The saphenous nerve was found within the pes anserine tendons in 77.6%/74.1% (m/f) of subjects, but outside the pes anserine tendons in 18.8%/15.3% (m/f). Visibility of sonoanatomic structures was not related to either gender or BMI. Conclusions Ultrasound provides very accurate information about variations in the pes anserine bursa and the saphenous nerve. This suggests that our proposed ultrasound method can be a reliable guide to facilitate approaches to the medial knee for diagnostic and therapeutic objectives. PMID:23861998

  10. Back to basics--how the evolution of the extracellular matrix underpinned vertebrate evolution.

    PubMed

    Huxley-Jones, Julie; Pinney, John W; Archer, John; Robertson, David L; Boot-Handford, Raymond P

    2009-04-01

    The extracellular matrix (ECM) is a complex substrate that is involved in and influences a spectrum of behaviours such as growth and differentiation and is the basis for the structure of tissues. Although a characteristic of all metazoans, the ECM has elaborated into a variety of tissues unique to vertebrates, such as bone, tendon and cartilage. Here we review recent advances in our understanding of the molecular evolution of the ECM. Furthermore, we demonstrate that ECM genes represent a pivotal family of proteins the evolution of which appears to have played an important role in the evolution of vertebrates.

  11. Bone morphogenetic protein 7 (BMP-7) influences tendon-bone integration in vitro.

    PubMed

    Schwarting, Tim; Lechler, Philipp; Struewer, Johannes; Ambrock, Marius; Frangen, Thomas Manfred; Ruchholtz, Steffen; Ziring, Ewgeni; Frink, Michael

    2015-01-01

    Successful graft ingrowth following reconstruction of the anterior cruciate ligament is governed by complex biological processes at the tendon-bone interface. The aim of this study was to investigate in an in vitro study the effects of bone morphogenetic protein 7 (BMP-7) on tendon-bone integration. To study the biological effects of BMP-7 on the process of tendon-bone-integration, two independent in vitro models were used. The first model involved the mono- and coculture of bovine tendon specimens and primary bovine osteoblasts with and without BMP-7 exposure. The second model comprised the mono- and coculture of primary bovine osteoblasts and fibroblasts. Alkaline phosphatase (ALP), lactate dehydrogenase (LDH), lactate and osteocalcin (OCN) were analyzed by ELISA. Histological analysis and electron microscopy of the tendon specimens were performed. In both models, positive effects of BMP-7 on ALP enzyme activity were observed (p<0.001). Additionally, similar results were noted for LDH activity and lactate concentration. BMP-7 stimulation led to a significant increase in OCN expression. Whereas the effects of BMP-7 on tendon monoculture peaked during an early phase of the experiment (p<0.001), the cocultures showed a maximal increase during the later stages (p<0.001). The histological analysis showed a stimulating effect of BMP-7 on extracellular matrix formation. Organized ossification zones and calcium carbonate-like structures were only observed in the BMP-stimulated cell cultures. This study showed the positive effects of BMP-7 on the biological process of tendon-bone integration in vitro. Histological signs of improved mineralization were paralleled by increased rates of osteoblast-specific protein levels in primary bovine osteoblasts and fibroblasts. Our findings indicated a role for BMP-7 as an adjuvant therapeutic agent in the treatment of ligamentous injuries, and they emphasized the importance of the transdifferentiation process of tendinous fibroblasts at the tendon-bone interface.

  12. Synergistic promoting effects of bone morphogenetic protein 12/connective tissue growth factor on functional differentiation of tendon derived stem cells and patellar tendon window defect regeneration.

    PubMed

    Xu, Kang; Sun, Yanjun; Kh Al-Ani, Mohanad; Wang, Chunli; Sha, Yongqiang; Sung, Kl Paul; Dong, Nianguo; Qiu, Xuefeng; Yang, Li

    2018-01-03

    Current study investigated bone morphogenetic protein 12 (BMP12) and connective tissue growth factor (CTGF) activate tendon derived stem cells (TDSCs) tenogenic differentiation, and promotion of injured tendon regeneration. TDSCs were transfected with BMP12 and CTGF via recombinant adenovirus (Ad) infection. Gene transfection efficiency, cell viability and cytotoxicity, tenogenic gene expression, collagen I/III synthesis were evaluated in vitro. For the in vivo study, the transfected cells were transplanted into the rat patellar tendon window defect. At weeks 2 and 8 of post-surgery, the repaired tendon tissues were harvested for histological and biomechanical examinations. The transfected TDSCs revealed relatively stable transfection efficiency (80-90%) with active cell viability means while rare cytotoxicity in each group. During days 1 and 5, BMP12 and CTGF transfection caused tenogenic differentiation genes activation in TDSCs: type I/III collagen, tenascin-C, and scleraxis were all up-regulated, whereas osteogenic, adipogenic, and chondrogenic markers were all down-regulated respectively. In addition, BMP12 and CTGF overexpression significantly promote type I/III collagen synthesis. After in vivo transplantation, at 2 and 8 weeks post-surgery, BMP12, CTGF and co-transfection groups showed more integrated tendon tissue structure versus control, meanwhile, the ultimate failure loads and Young's were all higher than control. Remarkably, at 8 weeks post-surgery, the biomechanical properties of co-transfection group was approaching to normal rat patellar tendon, moreover, the ratio of type III/I collagen maintained about 20% in each transfection group, meanwhile, the type I collagen were significantly increased with co-transfection treatment. In conclusion, BMP12 and CTGF transfection stimulate tenogenic differentiation of TDSCs. The synergistic effects of simultaneous transfection of both may significantly promoted rat patellar tendon window defect regeneration. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Achilles Tendon Penetration for Continuous 810 nm and Superpulsed 904 nm Lasers Before and After Ice Application: An In Situ Study on Healthy Young Adults.

    PubMed

    Haslerud, Sturla; Naterstad, Ingvill Fjell; Bjordal, Jan Magnus; Lopes-Martins, Rodrigo Alvaro Brandão; Magnussen, Liv Heide; Leonardo, Patrícia Sardinha; Marques, Ricardo Henrique; Joensen, Jon

    2017-10-01

    There is a lack of knowledge about the influence tissue temperature may have on laser light penetration and tendon structure. The purpose of this study was to investigate whether penetration of laser energy in human Achilles tendons differed before and after ice pack application. The Achilles tendons (n = 54) from 27 healthy young adults were irradiated with two class 3B lasers (810 nm 200 mW continuous mode laser and a 904 nm 60 mW superpulsed mode laser). The optical energy penetrating the Achilles area was measured before and after 20 min of ice application. Measurements were obtained after 30, 60, and 120 sec irradiation with the 904 nm laser and after 30 and 60 sec irradiation with the 810 nm laser. Achilles tendon thickness was measured with ultrasonography. Optical energy penetration increased significantly (p < 0.01) after ice application for both lasers and at all time points from 0.34% to 0.39% of energy before ice application to 0.43-0.52% of energy after ice application for the 904 nm laser and from 0.24% to 0.25% of energy before ice application to 0.30-0.31% of energy after ice application for the 810 nm laser. The energy loss per centimeter of irradiated tissue was significantly higher (p < 0.05) at all time points after ice application. Ultrasonography imaging of skin-to-skin and transversal tendon thickness was significantly reduced after ice application at p = 0.05 and p = 0.03, respectively. Achilles tendon thickness in the longitudinal plane remained unchanged (p = 0.49). The penetration of laser light increased significantly through healthy Achilles tendons subjected to 20 min of cooling. These findings occurred in the presence of a significant reduction in skin temperature and Achilles tendon thickness.

  14. Engineering complex orthopaedic tissues via strategic biomimicry.

    PubMed

    Qu, Dovina; Mosher, Christopher Z; Boushell, Margaret K; Lu, Helen H

    2015-03-01

    The primary current challenge in regenerative engineering resides in the simultaneous formation of more than one type of tissue, as well as their functional assembly into complex tissues or organ systems. Tissue-tissue synchrony is especially important in the musculoskeletal system, wherein overall organ function is enabled by the seamless integration of bone with soft tissues such as ligament, tendon, or cartilage, as well as the integration of muscle with tendon. Therefore, in lieu of a traditional single-tissue system (e.g., bone, ligament), composite tissue scaffold designs for the regeneration of functional connective tissue units (e.g., bone-ligament-bone) are being actively investigated. Closely related is the effort to re-establish tissue-tissue interfaces, which is essential for joining these tissue building blocks and facilitating host integration. Much of the research at the forefront of the field has centered on bioinspired stratified or gradient scaffold designs which aim to recapitulate the structural and compositional inhomogeneity inherent across distinct tissue regions. As such, given the complexity of these musculoskeletal tissue units, the key question is how to identify the most relevant parameters for recapitulating the native structure-function relationships in the scaffold design. Therefore, the focus of this review, in addition to presenting the state-of-the-art in complex scaffold design, is to explore how strategic biomimicry can be applied in engineering tissue connectivity. The objective of strategic biomimicry is to avoid over-engineering by establishing what needs to be learned from nature and defining the essential matrix characteristics that must be reproduced in scaffold design. Application of this engineering strategy for the regeneration of the most common musculoskeletal tissue units (e.g., bone-ligament-bone, muscle-tendon-bone, cartilage-bone) will be discussed in this review. It is anticipated that these exciting efforts will enable integrative and functional repair of soft tissue injuries, and moreover, lay the foundation for the development of composite tissue systems and ultimately, total limb or joint regeneration.

  15. Engineering Complex Orthopaedic Tissues via Strategic Biomimicry

    PubMed Central

    Qu, Dovina; Mosher, Christopher Z.; Boushell, Margaret K.; Lu, Helen H.

    2014-01-01

    The primary current challenge in regenerative engineering resides in the simultaneous formation of more than one type of tissue, as well as their functional assembly into complex tissues or organ systems. Tissue-tissue synchrony is especially important in the musculoskeletal system, whereby overall organ function is enabled by the seamless integration of bone with soft tissues such as ligament, tendon, or cartilage, as well as the integration of muscle with tendon. Therefore, in lieu of a traditional single-tissue system (e.g. bone, ligament), composite tissue scaffold designs for the regeneration of functional connective tissue units (e.g. bone-ligament-bone) are being actively investigated. Closely related is the effort to re-establish tissue-tissue interfaces, which is essential for joining these tissue building blocks and facilitating host integration. Much of the research at the forefront of the field has centered on bioinspired stratified or gradient scaffold designs which aim to recapitulate the structural and compositional inhomogeneity inherent across distinct tissue regions. As such, given the complexity of these musculoskeletal tissue units, the key question is how to identify the most relevant parameters for recapitulating the native structure-function relationships in the scaffold design. Therefore, the focus of this review, in addition to presenting the state-of-the-art in complex scaffold design, is to explore how strategic biomimicry can be applied in engineering tissue connectivity. The objective of strategic biomimicry is to avoid over-engineering by establishing what needs to be learned from nature and defining the essential matrix characteristics that must be reproduced in scaffold design. Application of this engineering strategy for the regeneration of the most common musculoskeletal tissue units (e.g. bone-ligament-bone, muscle-tendon-bone, cartilage-bone) will be discussed in this review. It is anticipated that these exciting efforts will enable integrative and functional repair of soft tissue injuries, and moreover, lay the foundation for the development of composite tissue systems and ultimately, total limb or joint regeneration. PMID:25465616

  16. Arthroscopic Medial Meniscus Posterior Root Reconstruction Using Auto-Gracilis Tendon.

    PubMed

    Lee, Dhong Won; Haque, Russel; Chung, Kyu Sung; Kim, Jin Goo

    2017-08-01

    There have been several techniques to repair the medial meniscus posterior root tears (MMPRTs) with the goal of restoring the anatomic and firm fixation of the meniscal root to bone. Many anatomic studies about the menisci also have been developed, so a better understanding of the anatomy could help surgeons perform correct fixation of the MMPRTs. The meniscal roots have ligament-like structures that firmly attach the menisci to the tibial plateau, and this structural concept is important to restore normal biomechanics after anatomic root repair. We present arthroscopic transtibial medial meniscus posterior root reconstruction using auto-gracilis tendon.

  17. Arthroscopic repair of traumatic isolated subscapularis tendon lesions (Lafosse Type III or IV): a prospective magnetic resonance imaging-controlled case series with 1 year of follow-up.

    PubMed

    Grueninger, Patrick; Nikolic, Nikola; Schneider, Joerg; Lattmann, Thomas; Platz, Andreas; Chmiel, Corinne; Meier, Christoph

    2014-06-01

    The purpose of this study was to prospectively assess the efficacy of arthroscopic repair of isolated high-grade subscapularis (SSC) tendon lesions by means of clinical follow-up combined with magnetic resonance imaging investigations. Between January 2008 and September 2010, 11 patients (9 men and 2 women; mean age, 45 ± 10 years) with Lafosse type III or IV traumatic isolated SSC tendon lesions underwent arthroscopic repair including tenodesis of the long head of the biceps tendon. All patients were preoperatively assessed by clinical examination (Constant-Murley score [CMS]) and contrast-enhanced magnetic resonance arthrography. At 1 year of follow-up, specific clinical SSC tests, the CMS, and the loss of external rotation were evaluated. A native magnetic resonance investigation was performed to assess the structural integrity of the repair. The SSC muscle was compared with its preoperative condition regarding fatty infiltration and size (cross-sectional area). Patient satisfaction was graded from 1 (poor) to 4 (excellent). The mean time interval from trauma to surgery was 3.7 months. A concomitant lesion of the biceps tendon was observed in 10 patients (91%). The mean CMS improved from 44 to 89 points (P < .001). The functional tests showed a significant increase in strength (P < .05) (belly-press test, 4.8 v 2.9; lift-off test, 4.8 v 2.9). The mean loss of external rotation at 0° of abduction was 10° compared with the contralateral side (P < .05). Patient satisfaction was high. Magnetic resonance imaging evaluation showed complete structural integrity of the tendon repair in all studies. The SSC showed a significant decrease in fatty infiltration and increase in the cross-sectional area. Arthroscopic repair of higher-grade isolated SSC lesions provides reliable tendon healing accompanied by excellent functional results 1 year after surgery. Level IV, prospective therapeutic case series. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  18. Unbonded prestressing tendons and their role in the construction of slender elements of buildings

    NASA Astrophysics Data System (ADS)

    Mieszczak, M.

    2018-03-01

    Steel unbonded tendons have been introduced in Europe for construction prestressing many years later than in the USA, Honkong, Singapore or Australia. In Poland, they appeared in the early 1990s. Despite their short application, in the last decade, the Institute of Materials and Building Constructions of the Cracow University of Technology in cooperation with the TCE Structural Design & Consulting company has developed and implemented several interesting and unique designs of building components, using the advantages of this type of prestressing. In the author’s work, apart from the short description of these tendons, several selected (own and foreign) projects of unique character have been presented.

  19. Anatomical variations of the carpal tunnel structures

    PubMed Central

    Mitchell, Ryan; Chesney, Amy; Seal, Shane; McKnight, Leslie; Thoma, Achilleas

    2009-01-01

    There are many anatomical variations in and around the carpal tunnel that affect the nerves, tendons and arteries in this area. Awareness of these variations is important both during the clinical examination and during carpal tunnel release. The purpose of the present review is to highlight recognized anatomical variations within the carpal tunnel including variation in nerve anatomy, tendon anatomical variants, vascular anatomical variations and muscle anatomical variations. PMID:20808747

  20. Electron Beam Irradiated Intercalated CNT Yarns For Aerospace Applications

    NASA Technical Reports Server (NTRS)

    Waters, Deborah L.; Gaier, James R.; Williams, Tiffany S.; Lopez Calero, Johnny E.; Ramirez, Christopher; Meador, Michael A.

    2015-01-01

    Multi-walled CNT yarns have been experimentally and commercially created to yield lightweight, high conductivity fibers with good tensile properties for application as electrical wiring and multifunctional tendons. Multifunctional tendons are needed as the cable structures in tensegrity robots for use in planetary exploration. These lightweight robust tendons can provide mechanical strength for movement of the robot in addition to power distribution and data transmission. In aerospace vehicles, such as Orion, electrical wiring and harnessing mass can approach half of the avionics mass. Use of CNT yarns as electrical power and data cables could reduce mass of the wiring by thirty to seventy percent. These fibers have been intercalated with mixed halogens to increase their specific electrical conductivity to that near copper. This conductivity, combined with the superior strength and fatigue resistance makes it an attractive alternative to copper for wiring and multifunctional tendon applications. Electron beam irradiation has been shown to increase mechanical strength in pristine CNT fibers through increased cross-linking. Both pristine and intercalated CNT yarns have been irradiated using a 5-megavolt electron beam for various durations and the conductivities and tensile properties will be discussed. Structural information obtained using a field emission scanning electron microscope, energy dispersive X-ray spectroscopy (EDS), and Raman spectroscopy will correlate microstructural details with bulk properties.

  1. The collagen structure of bovine intervertebral disc studied using polarization-sensitive optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Matcher, Stephen J.; Winlove, C. Peter; Gangnus, Sergei V.

    2004-04-01

    Polarization-sensitive optical coherence tomography (PS-OCT) is used to measure the birefringence properties of bovine intervertebral disc and equine flexor tendon. For equine tendon the birefringence Dgrn is (6.0 ± 0.2) × 10-3 at a wavelength of 1.3 µm. This is somewhat larger than the values reported for bovine tendon. The surface region of the annulus fibrosus of a freshly excised intact bovine intervertebral disc displays an identical value of birefringence, Dgrn = (6.0 ± 0.6) × 10-3 at 1.3 µm. The nucleus pulposus does not display birefringence, the measured apparent value of Dgrn = (0.39 ± 0.01) × 10-3 being indistinguishable from the effects of depolarization due to multiple scattering. A clear difference is found between the depth-resolved retardance of equine tendon and that of bovine intervertebral disc. This apparently relates to the lamellar structure of the latter tissue, in which the collagen fibre orientation alternates between successive lamellae. A semi-empirical model based on Jones calculus shows that the measurements are in reasonable agreement with previous optical and x-ray data. These results imply that PS-OCT could be a useful tool to study collagen organization within the intervertebral disc in vitro and possibly in vivo and its variation with applied load and disease.

  2. Imaging and simulation of Achilles tendon dynamics: implications for walking performance in the elderly

    PubMed Central

    Franz, Jason R.; Thelen, Darryl G.

    2016-01-01

    The Achilles tendon (AT) is a complex structure, consisting of distinct fascicle bundles arising from each triceps surae muscle that may act as mechanically independent structures. Advances in tissue imaging are rapidly accelerating our understanding of the complexities of functional Achilles tendon behavior, with potentially important implications for musculoskeletal injury and performance. In this overview of our recent contributions to these efforts, we present the results of complementary experimental and computational approaches to investigate AT behavior during walking and its potential relevance to reduced triceps surae mechanical performance due to aging. Our experimental evidence reveals that older tendons exhibit smaller differences in tissue deformations than young adults between regions of the AT presumed to arise from the gastrocnemius and soleus muscles. These observations are consistent with a reduced capacity for inter-fascicle sliding within the AT, which could have implications for the mechanical independence of the triceps surae muscles. More uniform AT deformations are also correlated with hallmark biomechanical features of elderly gait – namely, a loss of net ankle moment, power, and positive work during push-off. Simulating age-related reductions in the capacity for inter-fascicle sliding in the AT during walking predicts detriments in gastrocnemius muscle-tendon mechanical performance coupled with underlying shifts in fascicle kinematics during push-off. AT compliance, also suspected to vary due to age, systematically modulates those effects. By integrating in vivo imaging with computational modeling, we have gained theoretical insight into multi-scale biomechanical changes due to aging, hypotheses regarding their functional effects, and opportunities for experiments that validate or invalidate these assertions. PMID:27209552

  3. Minimally invasive repair of the tibialis anterior tendon using a semitendinosus autograft.

    PubMed

    Michels, Frederick; Van Der Bauwhede, Jan; Oosterlinck, Dirk; Thomas, Sam; Guillo, Stéphane

    2014-03-01

    Ruptures of the tibialis anterior tendon are rare but can cause substantial functional deficiencies. The literature regarding the treatment of such injuries is very limited. Atraumatic ruptures often occur in the presence of an abnormal tendon structure, and retraction often makes end-to-end repair impossible. With traumatic lesions, the risk of developing both adhesions and scar tissue is high. This study assesses the results of a surgical reconstruction using the interposition of a semitendinosus tendon autograft in 12 patients. Three patients had a traumatic rupture, and 9 patients had an atraumatic rupture. In 8 patients, the procedure was carried out using a minimally invasive technique. The average postoperative American Orthopaedic Foot & Ankle Society (AOFAS) Ankle-Hindfoot score was 95.7 in the atraumatic group and 94.7 in the traumatic group. Active dorsiflexion was possible after 2 to 3 weeks. We believe that the interposition of a strong, healthy tendon facilitated healing and allowed early weight bearing. All patients had good recovery of dorsiflexion and gait. Repairing a ruptured tibialis anterior tendon using a semitendinosus autograft was a reliable technique and offered a good result. With the minimally invasive approach, there was no need to divide the extensor retinaculum, which we believe allowed faster recovery and reduced the risk of adhesions and wound healing problems. Level IV, retrospective case series.

  4. Diabetes Mellitus Alters the Mechanical Properties of the Native Tendon in an Experimental Rat Model

    PubMed Central

    Fox, Alice J. S.; Bedi, Asheesh; Deng, Xiang-Hua; Ying, Liang; Harris, Paul E.; Warren, Russell F.; Rodeo, Scott A.

    2017-01-01

    The purpose of this study was to determine the effect of the diabetic phenotype on the mechanical properties of the native patellar tendon and its enthesis. Diabetes was induced via intraperitoneal injection of streptozotocin in Lewis rats. Control (n = 18) and diabetic animals(n = 20) were killed at 12 and 19 days for analysis. Statistical comparisons were performed using Student’s t-tests and a two-tailed Fisher test with significance set at p < 0.05. Pre- and post-injection intraperitoneal glucose tolerance tests demonstrated significant impairment of glycemic control in the diabetic compared to control animals (p = 0.001). Mean serum hemoglobin A1c levels at 19 days was 10.6 ± 2.7% and 6.0 ± 1.0% for the diabetic and control groups, respectively (p = 0.0001). Fifteen of sixteen diabetic animals demonstrated intrasubstance failure of the patellar tendon, while only 7 of 14 control specimens failed within the tendon substance. The Young’s modulus of the diabetic tendon was significantly lower than control specimens by 19 days post-induction (161 ± 10 N m−2 compared to 200 ± 46 N m−2, respectively) (p = 0.02). The metabolic condition of poorly controlled diabetes negatively affects the mechanical properties of the native patellar tendon. These altered structural properties may predispose diabetic patients to a greater risk of tendinopathy and/or traumatic rupture. PMID:21246619

  5. Exercise following a short immobilization period is detrimental to tendon properties and joint mechanics in a rat rotator cuff injury model.

    PubMed

    Peltz, Cathryn D; Sarver, Joseph J; Dourte, Leann M; Würgler-Hauri, Carola C; Williams, Gerald R; Soslowsky, Louis J

    2010-07-01

    Rotator cuff tears are a common clinical problem that can result in pain and disability. Previous studies in a rat model showed enhanced tendon to bone healing with postoperative immobilization. The objective of this study was to determine the effect of postimmobilization activity level on insertion site properties and joint mechanics in a rat model. Our hypothesis was that exercise following a short period of immobilization will cause detrimental changes in insertion site properties compared to cage activity following the same period of immobilization, but that passive shoulder mechanics will not be affected. We detached and repaired the supraspinatus tendon of 22 Sprague-Dawley rats, and the injured shoulder was immobilized postoperatively for 2 weeks. Following immobilization, rats were prescribed cage activity or exercise for 12 weeks. Passive shoulder mechanics were determined, and following euthanasia, tendon cross-sectional area and mechanical properties were measured. Exercise following immobilization resulted in significant decreases compared to cage activity in range of motion, tendon stiffness, modulus, percent relaxation, and several parameters from both a structurally based elastic model and a quasi-linear viscoelastic model. Therefore, we conclude that after a short period of immobilization, increased activity is detrimental to both tendon mechanical properties and shoulder joint mechanics, presumably due to increased scar production. (c) 2010 Orthopaedic Research Society. Published by Wiley Periodicals, Inc

  6. 3D Mimicry of Native-Tissue-Fiber Architecture Guides Tendon-Derived Cells and Adipose Stem Cells into Artificial Tendon Constructs.

    PubMed

    Laranjeira, Mariana; Domingues, Rui M A; Costa-Almeida, Raquel; Reis, Rui L; Gomes, Manuela E

    2017-08-01

    Tendon and ligament (T/L) function is intrinsically related with their unique hierarchically and anisotropically organized extracellular matrix. Their natural healing capacity is, however, limited. Here, continuous and aligned electrospun nanofiber threads (CANT) based on synthetic/natural polymer blends mechanically reinforced with cellulose nanocrystals are produced to replicate the nanoscale collagen fibrils grouped into microscale collagen fibers that compose the native T/L. CANT are then incrementally assembled into 3D hierarchical scaffolds, resulting in woven constructions, which simultaneously mimic T/L nano-to-macro architecture, nanotopography, and nonlinear biomechanical behavior. Biological performance is assessed using human-tendon-derived cells (hTDCs) and human adipose stem cells (hASCs). Scaffolds nanotopography and microstructure induce a high cytoskeleton elongation and anisotropic organization typical of tendon tissues. Moreover, the expression of tendon-related markers (Collagen types I and III, Tenascin-C, and Scleraxis) by both cell types, and the similarities observed on their expression patterns over time suggest that the developed scaffolds not only prevent the phenotypic drift of hTDCs, but also trigger tenogenic differentiation of hASCs. Overall, these results demonstrate a feasible approach for the scalable production of 3D hierarchical scaffolds that exhibit key structural and biomechanical properties, which can be advantageously explored in acellular and cellular T/L TE strategies. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. The effects of chronic unloading and gap formation on tendon-to-bone healing in a rat model of massive rotator cuff tears.

    PubMed

    Killian, Megan L; Cavinatto, Leonardo; Shah, Shivam A; Sato, Eugene J; Ward, Samuel R; Havlioglu, Necat; Galatz, Leesa M; Thomopoulos, Stavros

    2014-03-01

    The objective of this study was to understand the effect of pre-repair rotator cuff chronicity on post-repair healing outcomes using a chronic and acute multi-tendon rat rotator cuff injury model. Full-thickness dual tendon injuries (supra- and infraspinatus) were created unilaterally in adult male Sprague Dawley rats, and left chronically detached for 8 or 16 weeks. After chronic detachment, tears were repaired and acute dual tendon injuries were created and immediately repaired on contralateral shoulders. Tissue level outcomes for bone, tendon, and muscle were assessed 4 or 8 weeks after repair using histology, microcomputed tomography, biomechanical testing, and biochemical assays. Substantial gap formation was seen in 35% of acute repairs and 44% of chronic repairs. Gap formation negatively correlated with mechanical and structural outcomes for both healing time points regardless of injury duration. Bone and histomorphometry, as well as biomechanics, were similar between acute and chronic injury and repair regardless of chronicity and duration of healing. This study was the first to implement a multi-tendon rotator cuff injury with surgical repair following both chronic and acute injuries. Massive tear in a rodent model resulted in gap formation regardless of injury duration which had detrimental effects on repair outcomes. © 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  8. Tendon and ligament injuries: the genetic component

    PubMed Central

    September, Alison V; Schwellnus, Martin P; Collins, Malcolm

    2007-01-01

    Tendons and ligaments within the upper and lower limbs are some of the more common sites of musculoskeletal injuries during physical activity. Several extrinsic and intrinsic factors have been shown to be associated with these injuries. More recently, studies have suggested that there is also, at least in part, a genetic component to the Achilles tendon, rotator cuff and anterior cruciate ligament injuries. However, specific genes have not been suggested to be associated with rotator cuff or anterior cruciate ligament injuries. Sequence variants of the tenascin C (TNC) gene, on the other hand, have been shown to be associated with Achilles tendinopathies and Achilles tendon ruptures, whereas a variant of the collagen V α 1 (COL5A1) gene has also been shown to be associated with Achilles tendinopathies. Both genes encode for important structural components of tendons and ligaments. The COL5A1 gene encodes for a component of type V collagen, which has an important role in regulating collagen fibre assembly and fibre diameters. The TNC gene, on the other hand, encodes for TNC, which regulates the tissue's response to mechanical load. To date, only variants in two genes have been shown to be associated with Achilles tendon injuries. In addition, although specific genes have not been identified, investigators have suggested that there is also a genetic component to both rotator cuff and anterior cruciate ligament injuries. In future, specific genotypes associated with increased risk of injury to specific tendons and ligaments can prevent these injuries by identifying individuals at higher risk. PMID:17261551

  9. The effects of sectioning the spring ligament on rearfoot stability and posterior tibial tendon efficiency.

    PubMed

    Jennings, Meagan M; Christensen, Jeffery C

    2008-01-01

    Posterior tibial tendon insufficiency has been implicated as a cause of adult acquired flatfoot. Multiple theories are debated as to whether or not a flatfoot deformity develops secondary to insufficiency of the posterior tibial tendon or of the ligamentous structures such as the spring ligament complex. This cadaveric study was undertaken in an attempt to determine the effect that sectioning the spring ligament complex has on foot stability, and whether engagement of the posterior tibial tendon would be able to compensate for the loss of the spring ligament complex. A 3-dimensional kinematic system and a custom-loading frame were used to quantify rotation about the talus, navicular, and calcaneus in 5 cadaveric specimens, before and after sectioning the spring ligament complex, while incremental tension was applied to the posterior tibial tendon. This study demonstrated that sectioning the spring ligament complex created instability in the foot for which the posterior tibial tendon was unable to compensate. Sectioning the spring ligament complex also produced significant changes in talar, navicular, and calcaneal rotations. During simulated midstance, the navicular plantarflexed, adducted, and everted; the talar head plantarflexed, adducted, and inverted; and the calcaneus plantarflexed, abducted, and everted, after sectioning the spring ligament complex. The results of this study indicate that the spring ligament complex is the major stabilizer of the arch during midstance and that the posterior tibial tendon is incapable of fully accommodating for its insufficiency, suggesting that the spring ligament complex should be evaluated and, if indicated, repaired in flatfoot reconstruction. 5.

  10. Treatment of posterior tibial tendon dysfunction without flexor digitorum tendon transfer: a retrospective study of 34 patients.

    PubMed

    Didomenico, Lawrence; Stein, Dawn Y; Wargo-Dorsey, Mari

    2011-01-01

    A retrospective study of patients who underwent gastrocnemius recession, double calcaneal osteotomy (Evans osteotomy and percutaneous calcaneal displacement osteotomy), and medial column fusion for the treatment of posterior tibial tendon dysfunction was conducted. The senior author performed the procedures between November 2002 and January 2009 on 34 patients who displayed at least Johnson and Strom stage II deformity and had undergone 12 months of failed conservative treatment. The coauthors evaluated the patients' radiographs before and after the operation. At a mean of 14 (range 3 to 44) months after surgery, radiographic measurements demonstrated statistically significant changes in the structural alignment of the feet. Based on our experience with these patients, we believe that a double calcaneal osteotomy combined with a gastrocnemius recession and stabilization of the medial column for the treatment of posterior tibial tendon dysfunction provides satisfactory correction, stability, and realignment of the foot. Furthermore, we feel that the use of flexor digitorum longus transfer, as well as triple arthrodesis, can be avoided without compromising the outcome when surgically treating posterior tibial tendon dysfunction. Copyright © 2011 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  11. Classification of the degenerative grade of lesions of supraspinatus rotator cuff tendons by FT-Raman spectroscopy

    NASA Astrophysics Data System (ADS)

    Palma Fogazza, Bianca; da Silva Carvalho, Carolina; Godoy Penteado, Sergio; Meneses, Cláudio S.; Abrahão Martin, Airton; da Silva Martinho, Herculano

    2007-02-01

    FT-Raman spectroscopy was employed to access the biochemical alterations occurring on the degenerative process of the rotator cuff supraspinatus tendons. The spectral characteristic variations in the 351 spectra of samples of 39 patients were identified with the help of Principal Components Analysis. The main variations occurred in the 840-911; 1022- 1218; 1257; 1270; 1300; 1452; 1663; and 1751 cm -1 regions corresponding to the vibrational bands of proline, hydroxiproline, lipids, nucleic acids, carbohydrates, collagen, and elastin. These alterations are compatible with the pathology alterations reported on the literature. Scattering plots of PC 4 vs PC 2 and PC 3 vs PC 2 contrasted with histopathological analysis has enabled the spectral classification of the data into normal and degenerated groups of tendons. By depicting empiric lines the estimated sensibility and specificity were 39,6 % and 97,8 %, respectively for PC 4 vs PC 2 and 36,0 % and 100 %, respectively for PC 3 vs PC 2. These results indicate that Raman spectroscopy can be used to probe the general tendon quality and could be applied as co adjuvant element in the usual arthroscopy surgery apparatus to guide the procedure and possibly infer about the probability of rerupture.

  12. Altered Gene and Protein Expressions in Torn Rotator Cuff Tendon Tissues in Diabetic Patients.

    PubMed

    Chung, Seok Won; Choi, Bo Mi; Kim, Ja Yeon; Lee, Yong-Soo; Yoon, Jong Pil; Oh, Kyung-Soo; Park, Kyung Sik

    2017-03-01

    To analyze and compare the gene and protein expression characteristics in torn rotator cuff tendon tissues between diabetic and nondiabetic patients. This was a pilot study. Twelve samples of rotator cuff tendon tissue from diabetic patients (mean age, 62.3 ± 9.9 years) and 12 age- and sex-matched nondiabetic tendon tissues (62.3 ± 9.9 years) were acquired from the torn tendon end of medium rotator cuff tears during arthroscopic surgery, after applying the same inclusion and exclusion criteria. Expressions of various genes of interest, including collagens I and III, matrix metalloprotease (MMP)-2, MMP-3, MMP-9, MMP-13, interleukin (IL)-1, IL-6, insulin-like growth factor-1, vascular endothelial growth factor, tenomodulin, tumor necrosis factor-α, and p53, were analyzed with real-time quantitative reverse transcription polymerase chain reaction (qRT-PCR). In addition, immunohistochemistry and western blot assay were performed for the genes that revealed significantly different expressions in real-time qRT-PCR between groups. Gene expression levels of MMP-9, MMP-13, IL-6, and tenomodulin were significantly higher in the diabetic than in the nondiabetic group by real-time qRT-PCR analyses (P = .011, .004, .009, and .010, respectively). The density of cells expressing MMP-9 and IL-6 was significantly increased in the torn tendons of the diabetic patients on immunohistochemical analysis, and the density of MMP-9 and IL-6 protein expressions was significantly higher in the diabetic group on western blot (P = .018 and .044, respectively). Diabetic torn cuff tendon tissues showed MMP-9 and IL-6 overexpressions compared with controls. The overexpressions of MMP-9 and IL-6 may be one of the explanations for the high healing failure rate after rotator cuff repair in the diabetic patients. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  13. Flexible bipolar nanofibrous membranes for improving gradient microstructure in tendon-to-bone healing.

    PubMed

    Li, Xiaoxi; Cheng, Ruoyu; Sun, Zhiyong; Su, Wei; Pan, Guoqing; Zhao, Song; Zhao, Jinzhong; Cui, Wenguo

    2017-10-01

    Enthesis is a specialized tissue interface between the tendon and bone. Enthesis structure is very complex because of gradient changes in its composition and structure. There is currently no strategy to create a suitable environment and to regenerate the gradual-changing enthesis because of the modular complexities between two tissue types. Herein, a dual-layer organic/inorganic flexible bipolar fibrous membrane (BFM) was successfully fabricated by electrospinning to generate biomimetic non-mineralized fibrocartilage and mineralized fibrocartilage in tendon-to-bone integration of enthesis. The growth of the in situ apatite nanoparticle layer was induced on the nano hydroxyapatite-poly-l-lactic acid (nHA-PLLA) fibrous layer in simulated body solution, and the poly-l-lactic acid (PLLA) fibrous layer retained its original properties to induce tendon regeneration. The in vivo results showed that BFM significantly increased the area of glycosaminoglycan staining at the tendon-bone interface and improved collagen organization when compared to the simplex fibrous membrane (SFM) of PLLA. Implanting the bipolar membrane also induced bone formation and fibrillogenesis as assessed by micro-CT and histological analysis. Biomechanical testing showed that the BFM group had a greater ultimate load-to-failure and stiffness than the SFM group at 12weeks after surgery. Therefore, this flexible bipolar nanofibrous membrane improves the healing and regeneration process of the enthesis in rotator cuff repair. In this study, we generated a biomimetic dual-layer organic/inorganic flexible bipolar fibrous membrane by sequential electrospinning and in situ biomineralization, producing integrated bipolar fibrous membranes of PLLA fibrous membrane as the upper layer and nHA-PLLA fibrous membrane as the lower layer to mimic non-mineralized fibrocartilage and mineralized fibrocartilage in tendon-to-bone integration of enthesis. Flexible bipolar nanofibrous membranes could be easily fabricated with gradient microstructure for enthesis regeneration in rotator cuff tears. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  14. The influence of exercise during growth on ultrasonographic parameters of the superficial digital flexor tendon of young Thoroughbred horses.

    PubMed

    Moffat, P A; Firth, E C; Rogers, C W; Smith, R K W; Barneveld, A; Goodship, A E; Kawcak, C E; McIlwraith, C W; van Weeren, P R

    2008-03-01

    Conditioning by early training may influence the composition of certain musculoskeletal tissues, but very few data exist on its effect during growth on tendon structure and function. To investigate whether conditioning exercise in young foals would lead to any ultrasonographically detectable damage to the superficial digital flexor tendon or an increase in cross-sectional area (CSA). Thirty-three Thoroughbred foals reared at pasture were allocated to 2 groups: control (PASTEX) allowed exercise freely at pasture; and CONDEX, also at pasture, began conditioning exercise from mean age 21 days over 1030 m on a purpose-built oval grass track, for 5 days/week until mean age 18 months. Foals were observed daily, and underwent orthopaedic examination monthly. Ultrasonographic images of the superficial digital flexor tendon (SDFT) at the mid-metacarpal level of both forelimbs were obtained in all foals at ages 5, 8, 12, 15 and 18 months. CSA was validated (r(2) = 0.89) by determining CSA from digital photographs of the transected SDFT surface from 12 of the horses necropsied at age 17.1 months. here was no clinical or ultrasonographic evidence of tendonopathy in either group and the greatest increase in mean CSA in both groups occurred between age 5 and 8 months. Across all age categories, there was no significant difference in mean CSA between the left and right limbs, or colts and fillies; there was a trend towards a larger CSA in the CONDEX group (P = 0.058). There was no conclusive evidence for a structural adaptive hypertrophy of the SDFT, probably because the regimen was insufficiently rigorous or because spontaneous pasture exercise may induce maximal development of energy storing tendons. A moderate amount of early conditioning exercise against a background of constant exercise at pasture is not harmful to the development of the flexor tendons.

  15. Return to Function, Complication, and Reoperation Rates Following Primary Pectoralis Major Tendon Repair in Military Service Members.

    PubMed

    Nute, Drew W; Kusnezov, Nicholas; Dunn, John C; Waterman, Brian R

    2017-01-04

    Pectoralis major tendon ruptures have become increasingly common injuries among young, active individuals over the past 30 years; however, there is presently a paucity of reported outcome data. We investigated the ability to return to full preoperative level of function, complications, reoperation rates, and risk factors for failure following surgical repair of the pectoralis major tendon in a cohort of young, highly active individuals. All U.S. active-duty military patients undergoing pectoralis major tendon repair between 2008 and 2013 were identified from the Military Health System using the Management Analysis and Reporting Tool (M2). Demographic characteristics, injury characteristics, and trends in preoperative and postoperative self-reported pain scale (0 to 10) and strength were extracted. The ability to return to the full preoperative level of function and rates of rerupture and reoperation were the primary outcome measures. Univariate analysis followed by multivariate analysis identified significant variables. A total of 257 patients with pectoralis major tendon repair were identified with a mean follow-up (and standard deviation) of 47.8 ± 17 months (range, 24 to 90 months). At the time of the latest follow-up, 242 patients (94%) were able to return to the full preoperative level of military function. Fifteen patients (5.8%) were unable to return to duty because of persistent upper-extremity disability. A total of 15 reruptures occurred in 14 patients (5.4%). Increasing body mass index and active psychiatric conditions were significant predictors of inability to return to function (odds ratio, 1.56 [p = 0.0001] for increasing body mass index; and odds ratio, 6.59 [p = 0.00165] for active psychiatric conditions) and total failure (odds ratio, 1.26 [p = 0.0012] for increasing body mass index; and odds ratio, 2.73 [p = 0.0486] for active psychiatric conditions). We demonstrate that 94% of patients were able to return to the full preoperative level of function within active military duty following surgical repair of pectoralis major tendon rupture and 5.4% of patients experienced rerupture after primary repair. Increasing body mass index and active psychiatric diagnoses are significant risk factors for an inability to return to function and postoperative failures. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

  16. Use of Posterior Hamstring Harvest During Anterior Cruciate Ligament Reconstruction in the Pediatric and Adolescent Population.

    PubMed

    Khanna, Krishn; Janghala, Abhinav; Pandya, Nirav K

    2018-06-01

    Posterior hamstring harvest has been described in the adult population in a limited fashion, but no study is available describing the use of posterior hamstring harvest in an active pediatric and adolescent cohort. At times, surgeons may be faced with a challenging anterior harvest due to patient anatomic characteristics, particularly the anatomic features and size of the pes tendons. Clinicians need to have multiple harvest approaches at their disposal. Complications with hamstring harvest such as premature graft transection are more problematic in this population due to higher failure rates with allograft tissue. The posterior harvest via its more proximal location may allow for easier tendon identification, visualization of the accessory attachments, and longer preserved tendon length if transection error occurs when the anterior approach is avoided based on surgical technique, patient anatomic characteristics, and surgeon and patient preference. To describe the technique of a posterior hamstring harvest in pediatric and adolescent patients and to analyze complications. Case series; Level of evidence, 4. This study was a retrospective review of a consecutive series of pediatric and adolescent patients who underwent posterior hamstring harvest. During surgery, the patient's leg was abducted and externally rotated to expose the posteromedial aspect of the knee. A 2-cm incision was made overlying the palpable medial hamstring at the popliteal crease. The posterior hamstring tendons were first harvested proximally with an open tendon stripper and distally with a closed stripper. Preoperative, intraoperative, and postoperative findings and complications were analyzed. A total of 214 patients (mean ± SD age, 15.7 ± 4.1 years; range, 8.0-19.8 years) underwent posterior harvest, with a mean ± SD follow-up of 1.83 ± 1.05 years. No complications occurred in our series related to graft harvest-no graft transections, neurovascular injuries, secondary procedures for wound healing or closure, cosmetic concerns, or limitations in return to activity due to the posterior incision. The posterior hamstring harvest is a safe and reliable technique to harvest autograft tendon in pediatric and adolescent anterior cruciate ligament reconstructions. The posterior technique entailed no complications related to harvest. No patients expressed any cosmetic concerns about their incision or had limitations in return to sport due to the posterior harvest.

  17. Uniformly-dispersed nanohydroxapatite-reinforced poly(ε-caprolactone) composite films for tendon tissue engineering application.

    PubMed

    Tong, Shi Yun; Wang, Zuyong; Lim, Poon Nian; Wang, Wilson; Thian, Eng San

    2017-01-01

    Regeneration of injuries at tendon-to-bone interface (TBI) remains a challenging issue due to the complex tissue composition involving both soft tendon tissues and relatively hard bone tissues. Tissue engineering using polymeric/ceramic composites has been of great interest to generate scaffolds for tissue's healing at TBI. Herein, we presented a novel method to blend polymers and bioceramics for tendon tissue engineering application. A homogeneous composite comprising of nanohydroxyapatite (nHA) particles in poly(ε-caprolactone) (PCL) matrix was obtained using a combination of solvent and mechanical blending process. X-ray diffraction analysis showed that the as-fabricated PCL/nHA composite film retained phase-pure apatite and semi-crystalline properties of PCL. Infrared spectroscopy spectra confirmed that the PCL/nHA composite film exhibited the characteristics functional groups of PCL and nHA, without alteration to the chemical properties of the composite. The incorporation of nHA resulted in PCL/nHA composite film with improved mechanical properties such as Young's Modulus and ultimate tensile stress, which were comparable to that of the native human rotator tendon. Seeding with human tenocytes, cells attached on the PCL/nHA composite film, and after 14days of culturing, these cells could acquire elongated morphology without induced cytotoxicity. PCL/nHA composite film could also result in increased cell metabolism with prolonged culturing, which was comparable to that of the PCL group and higher than that of the nHA group. All these results demonstrated that the developed technique of combining solvent and mechanical blending could be applied to fabricate composite films with potential for tendon tissue engineering applications. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Evaluating the Role of Subacromial Impingement in Rotator Cuff tendinopathy: Development and Analysis of a Novel Murine Model.

    PubMed

    Cong, Guang-Ting; Lebaschi, Amir H; Camp, Christopher L; Carballo, Camila B; Nakagawa, Yusuke; Wada, Susumu; Deng, Xiang-Hua; Rodeo, Scott A

    2018-04-23

    Subacromial impingement of the rotator cuff is understood as a contributing factor in the development of rotator cuff tendinopathy. However, changes that occur in the impinged tendon are poorly understood and warrant further study. To enable further study of rotator cuff tendinopathy, we performed a controlled laboratory study to determine feasibility and baseline characteristics of a new murine model for subacromial impingement. This model involves surgically inserting a microvascular clip into the subacromial space in adult C57Bl/6 mice. Along with a sham surgery arm, 90 study animals were distributed among time point groups for sacrifice up to 6 weeks. All animals underwent bilateral surgery (total N = 180). Biomechanical, histologic, and molecular analyses were performed to identify and quantify the progression of changes in the supraspinatus tendon. Decreases in failure force and stiffness were found in impinged tendon specimens compared to sham and no-surgery controls at all study time points. Semi-quantitative scoring of histologic specimens demonstrated significant, persistent tendinopathic changes over 6 weeks. Quantitative real-time polymerase chain reaction analysis of impinged tendon specimens demonstrated persistently increased expression of genes related to matrix remodeling, inflammation, and tendon development. Overall, this novel murine subacromial impingement model creates changes consistent with acute tendonitis, which may mimic the early stages of rotator cuff tendinopathy. This article is protected by copyright. All rights reserved Clinical Significance: A robust, simple, and reproducible animal model of rotator cuff tendinopathy is a valuable research tool to allow further studies of cellular and molecular mechanisms and evaluation of therapeutic interventions in rotator cuff tendinopathy. This article is protected by copyright. All rights reserved.

  19. [Bursitis with severe tendon and muscle necrosis on the lateral stifle area in cattle].

    PubMed

    Nuss, K; Räber, M; Sydler, T; Muggli, E; Hässig, M; Guscetti, F

    2011-11-01

    In 21 animals, chronic swelling on the lateral aspect of the stifle also known as «perigonitis», «stable-syndrome» or «bursitis bicipitalis femoris» were evaluated. Ultrasonography showed increased fluid in the distal subtendinous bursa of the biceps femoris muscle and structural changes in the tendons, muscles, subcutis and fasciae. Soft tissue swelling and an irregular contour of the lateral tibial condyle were typical signs on radiographs. Macroscopic changes were found at the insertion of the biceps femoris muscle, the distal subtendinous bursa of the biceps femoris muscle, the lateral collateral ligament of the stifle, the origin of muscles on the lateral femoral condyle and the lateral tibial condyle. They mainly consisted of tendon and muscle tissue necrosis with granulation tissue. Histology revealed areas of coagulation necrosis in tendons and ligaments, in which occasionally Onchocerca spp. were seen. The severity of lesions correlated well with the clinical signs, which were associated with a poor prognosis in advanced cases.

  20. 75 FR 62893 - Draft Regulatory Guide: Issuance, Availability

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-13

    ... for using portland cement grout to protect prestressing steel from corrosion. The prestressing tendon system of a prestressed concrete containment structure is a principal strength element of the structure... of the structure depends on the functional reliability of the structure's principal strength elements...

  1. The influence of the mechanical behaviour of the middle ear ligaments: a finite element analysis.

    PubMed

    Gentil, F; Parente, M; Martins, P; Garbe, C; Jorge, R N; Ferreira, A; Tavares, João Manuel R S

    2011-01-01

    The interest in computer modelling of biomechanical systems, mainly by using the finite element method (FEM), has been increasing, in particular for analysis of the mechanical behaviour of the human ear. In this work, a finite element model of the middle ear was developed to study the dynamic structural response to harmonic vibrations for distinct sound pressure levels applied on the eardrum. The model includes different ligaments and muscle tendons with elastic and hyperelastic behaviour for these supportive structures. Additionally, the nonlinear behaviour of the ligaments and muscle tendons was investigated, as they are the connection between ossicles by contact formulation. Harmonic responses of the umbo and stapes footplate displacements, between 100 Hz and 10 kHz, were obtained and compared with previously published work. The stress state of ligaments (superior, lateral, and anterior of malleus and superior and posterior of incus) was analysed, with the focus on balance of the supportive structures of the middle ear, as ligaments make the link between the ossicular chain and the walls of the tympanic cavity. The results obtained in this work highlight the importance of using hyperelastic models to simulate the mechanical behaviour for the ligaments and tendons.

  2. The relationship of lateral anatomic structures to exiting guide pins during femoral tunnel preparation utilizing an accessory medial portal.

    PubMed

    Farrow, Lutul D; Parker, Richard D

    2010-06-01

    Anatomic reconstruction of the anterior cruciate ligament through an accessory medial portal has become increasingly popular. The purpose of this study is to describe the relationship of guide pin exit points to the lateral anatomic structures when preparing the anterior cruciate ligament femoral tunnel through an accessory medial portal. We utilized seven fresh frozen cadaveric knees. Utilizing an anteromedial approach, a guide wire was placed into the center of each bundle's footprint. Each guide wire was advanced through the lateral femoral cortex. The guide pins were passed at 90, 110, and 130 degrees of knee flexion. The distances from each guide pin to the closest relevant structures on the lateral side of the knee were measured. At 90 degrees the posterolateral bundle guide pin was closest to the lateral condyle articular cartilage (mean 5.4 +/- 2.2 mm) and gastrocnemius tendon (mean 5.7 +/- 2.1 mm). At 110 degrees the posterolateral bundle pin was closest to the gastrocnemius tendon (mean 4.5 +/- 3.4 mm). At 130 degrees the posterolateral bundle pin was closest to the gastrocnemius tendon (mean 7.2 +/- 5.5 mm) and lateral collateral ligament (mean 6.8 +/- 2.1 mm). At 90 degrees the anteromedial bundle guide pin was closest to the articular cartilage (mean 2.0 +/- 2.0 mm). At 110 degrees the anteromedial bundle pin was closest to the articular cartilage (mean 7.4 +/- 3.5 mm) and gastrocnemius tendon (mean 12.3 +/- 3.1 mm). At 130 degrees the AM bundle pin was closest to the gastrocnemius tendon (mean 8.2 +/- 3.2 mm) and LCL (mean 15.1 +/- 2.9 mm). Neither guide pin (anteromedial or posterolateral bundle) put the peroneal nerve at risk at any knee flexion angle. At low knee flexion angles the anteromedial and posterolateral bundle guide pins closely approximated multiple lateral structures when using an accessory medial arthroscopic portal. Utilizing higher flexion angles increases the margin of error when preparing both femoral tunnels. During preparation of the anterior cruciate ligament femoral tunnel through an accessory anteromedial portal the tunnels should be drilled in at least 110 degrees of knee flexion in order to move guide pin exit points away from important lateral knee structures.

  3. Increased mast cell numbers in a calcaneal tendon overuse model.

    PubMed

    Pingel, J; Wienecke, J; Kongsgaard, M; Behzad, H; Abraham, T; Langberg, H; Scott, A

    2013-12-01

    Tendinopathy is often discovered late because the initial development of tendon pathology is asymptomatic. The aim of this study was to examine the potential role of mast cell involvement in early tendinopathy using a high-intensity uphill running (HIUR) exercise model. Twenty-four male Wistar rats were divided in two groups: running group (n = 12); sedentary control group (n = 12). The running-group was exposed to the HIUR exercise protocol for 7 weeks. The calcaneal tendons of both hind limbs were dissected. The right tendon was used for histologic analysis using Bonar score, immunohistochemistry, and second harmonic generation microscopy (SHGM). The left tendon was used for quantitative polymerase chain reaction (qPCR) analysis. An increased tendon cell density in the runners were observed compared to the controls (P = 0.05). Further, the intensity of immunostaining of protein kinase B, P = 0.03; 2.75 ± 0.54 vs 1.17 ± 0.53, was increased in the runners. The Bonar score (P = 0.05), and the number of mast cells (P = 0.02) were significantly higher in the runners compared to the controls. Furthermore, SHGM showed focal collagen disorganization in the runners, and reduced collagen density (P = 0.03). IL-3 mRNA levels were correlated with mast cell number in sedentary animals. The qPCR analysis showed no significant differences between the groups in the other analyzed targets. The current study demonstrates that 7-week HIUR causes structural changes in the calcaneal tendon, and further that these changes are associated with an increased mast cell density. © 2013 The Authors. Scand J Med Sci Sports published by John Wiley & Sons Ltd.

  4. Anatomy and relations of the infraspinatus and the teres minor muscles: a fresh cadaver dissection study.

    PubMed

    Bacle, Guillaume; Gregoire, Jean-Marc; Patat, Frédéric; Clavert, Philippe; de Pinieux, Gonzague; Laulan, Jacky; Lakhal, Walid; Favard, Luc

    2017-02-01

    Despite their functional importance, the infraspinatus (ISP) and teres minor (TM) muscles have been little investigated. This study aimed to describe the macroscopic morphology, innervation, and inter-relations of the ISP and TM muscles. Forty fresh cadaver dissections and histologic analysis were performed. Three groups of specimens were distinguished according to the rotator cuff tendon status: (1) intact rotator cuff; (2) supraspinatus tendon tears with intact ISP tendon; and (3) both supraspinatus and ISP tendons torn. Muscle fiber organization and muscle and tendon length were recorded. ISP and TM innervation and fiber structure were studied. ISP muscles were composed of three groups of fiber organized in two planes: two superficial groups, with mean pennation angles of, respectively, 27° ± 4° and 23° ± 3° with respect to the axis of the central tendon of the underlying group. TMs were thick fusiform muscles showing a parallel organization; 26 specimens (67 %) had aponeuroses isolating the TM, with a mean length of 5.2 ± 2.7 cm. Rotator cuff lesions were associated with relatively greater ISP tendon than muscle length. Innervation of the ISP muscle comprised 2-4 main branches from the suprascapular nerve and that of the TM 1 branch from the axillary nerve. ISP muscle body morphology derives from three groups of fibers in two planes. The TM has a parallel organization. Several nerve branches innervate the ISP muscle, whereas only one supplies the TM. The limits between the two muscles bodies consist of an aponeurotic fascia in two-thirds of cases.

  5. VGluT2 expression in painful Achilles and patellar tendinosis: evidence of local glutamate release by tenocytes.

    PubMed

    Scott, Alexander; Alfredson, Håkan; Forsgren, Sture

    2008-05-01

    The pathogenesis of chronic tendinopathy is unclear. We have previously measured high intratendinous levels of glutamate in patients with tendinosis, suggesting potential roles of glutamate in the modulation of pain, vascular function, and degenerative changes including apoptosis of tenocytes. However, the origin of free glutamate found in tendon tissue is completely unknown. Surgical biopsies of pain-free normal tendons and tendinosis tendons (Achilles and patellar) were examined immunohistochemically using antibodies against vesicular glutamate transporters (VGluT1 and VGluT2), as indirect markers of glutamate release. In situ hybridization for VGluT2 mRNA was also conducted. Specific immunoreactions for VGluT2, but not VGluT1, could be consistently detected in tenocytes. However, there were interindividual variations in the levels of immunoreactivity. The level of immunoreaction for VGluT2 was higher in tendinosis tendons compared to normal tendons (p < 0.05). In situ hybridization of VGluT2 demonstrated that mRNA was localized in a similar pattern as the protein, with marked expression by certain tenocytes, particularly those showing abnormal appearances. Reactivity for VGluT1 and -2 was absent from nerves and vessel structures in both normal and painful tendons. The current data demonstrate that tenocytes may be involved in the regulation of extracellular glutamate levels in tendons. Specifically, the observations suggest that free glutamate may be locally produced and released by tenocytes, rather than by peripheral neurons. Excessive free glutamate is expected to impact a variety of autocrine and paracrine functions important in the development of tendinosis, including tenocyte proliferation and apoptosis, extracellular matrix metabolism, nociception, and blood flow. (c) 2007 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  6. Anatomical feasibility study of flexor hallucis longus transfer in treatment of Achilles tendon and posteromedial portal of ankle arthroscopy.

    PubMed

    Mao, Haijiao; Wang, Linger; Dong, Wenwei; Liu, Zhenxin; Yin, Weigang; Xu, Dachuan; Wapner, Keith L

    2018-04-16

    The aim of this study was to evaluate the occurrence of anatomical variations of the musculotendinous junction of the flexor hallucis longus (FHL) muscle, the relationship between FHL tendon or muscle and the tibial neurovascular bundle at the level of the posterior ankle joint in human cadavers. Seventy embalmed feet from 20 male and 15 female cadavers, the cadavers' mean age was 65.4 (range from 14 to 82) years, were dissected and anatomically classified to observe FHL muscle morphology define the relationship between FHL tendon or muscle and the tibial neurovascular bundle. The distance between the musculotendinous junction and the relationship between FHL tendon or muscle and the tibial neurovascular bundle was determined. Three morphology types of FHL muscle were identified: a long lateral and shorter medial muscle belly, which was observed in 63 specimens (90%); equal length medial and lateral muscle bellies, this variant was only observed in five specimens (7.1%); one lateral and no medial muscle belly, which was observed in two specimens (2.9%). No statistically significant difference was observed according to gender or side (p > 0.05). Two patterns were identified and described between FHL tendon or muscle and the tibial neurovascular bundle. Pattern 1, the distance between the neurovascular bundle and FHL tendon was 3.46 mm (range 2.34-8.84, SD = 2.12) which was observed in 66 specimens (94.3%); Pattern 2, there was no distance which was observed in four specimens (5.7%). Knowing FHL muscle morphology, variations provide new important insights into secure planning and execution of a FHL transfer for Achilles tendon defect as well as for the interpretation of ultrasound and magnetic resonance images. With posterior arthroscopic for the treatment of various ankle pathologies, posteromedial portal may be introduced into the posterior aspect of the ankle without gross injury to the tibial neurovascular structures because of the gap between the neurovascular bundle and FHL tendon.

  7. Prolonged stretching of the ankle plantarflexors elicits muscle-tendon adaptations relevant to ankle gait kinetics in children with spastic cerebral palsy.

    PubMed

    Martín Lorenzo, Teresa; Rocon, Eduardo; Martínez Caballero, Ignacio; Ramírez Barragán, Ana; Lerma Lara, Sergio

    2017-11-01

    Tissue related ankle hyper-resistance has been reported to contribute to equinus gait in children with spastic cerebral palsy. Hence, ankle plantarflexor stretching programs have been developed in order to restore passive ankle dorsiflexion. Despite high quality evidence on the limited effects of stretching on passive joint mobility, further muscle-tendon adaptations have been reported which may impact gait performance. As such, children with spastic cerebral palsy subject to long-term manual static stretching achieved dorsiflexion gains through the reduction of muscle and fascicle strain whilst preserving tendon strain, and prolonged use of ankle-foot orthoses achieved similar dorsiflexion gains through increased tendon strain whilst preserving muscle and fascicle strain. The latter concurred with normalization of early stance plantarflexor moment yet reductions in push-off plantarflexor moment given the increase in tendon compliance. Therefore, similar limited gains in passive ankle joint mobility in response to stretching may be achieved either by preserving/restoring optimal muscle-tendon function, or at the expense of muscle-tendon function and thus contributing gait impairments. The largest increase in ankle passive joint mobility in children with SCP has been obtained through prolonged plantarflexor stretching through ankle casting combined with botulinum neurotoxin type A. However, to our knowledge, there are no published studies on muscle-tendinous adaptations to ankle casting combined with botulinum toxin type A and its effect on ankle joint gait kinetics. Therefore, we hypothesized that ankle casting elicits muscle-tendon adaptations which concur with altered ankle joint kinetics during the stance phase of gait in children with SCP. More information is needed about the relationships between muscle structure and function, and the effect of specific interventions designed to alter muscle properties and associated functional outcomes in children with spastic cerebral palsy. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Arthroscopic treatment of chronically painful calcifying tendinitis of the supraspinatus tendon.

    PubMed

    Seil, Romain; Litzenburger, Heike; Kohn, Dieter; Rupp, Stefan

    2006-05-01

    The purpose of this study was to analyze the outcome of arthroscopic removal of calcifying tendinitis of the rotator cuff, to document the postoperative pain evolution, and to analyze structural changes of the supraspinatus tendon by use of ultrasonography. Fifty-four of 58 patients with a mean age of 45.4 years (+/-8 years) enrolled in the study were available for follow-up. The calcific deposits were exclusively located in the supraspinatus tendon. Shoulder function was evaluated by using the Constant score. Radiographs were obtained preoperatively, immediately postoperatively, and at 3, 6, 12, and 24 months. The integrity of the rotator cuff was assessed by using ultrasonography. Shoulder function according to the Constant score improved from 32.8 points (+/-19.8) preoperatively to 90.9 (+/-13.0) at 24 months (P < 0.001). The evolution of postoperative pain was very irregular; 31% of the patients were pain free or reached their minimum pain level after 3 months, 17% after 6 months, 20% after 9 months, and 28% after 12 months; 78% of the patients returned to work within 6 weeks, irrespective of their profession. At the final follow-up 92% of the patients were very satisfied with the outcome. Ultrasonography revealed minor structural changes of the supraspinatus tendon in 66% of the patients. The study confirmed previously reported successful results of arthroscopic treatment of calcifying tendinitis of the rotator cuff. Complete intraoperative removal of the deposit did not appear to be essential. Even if most of the patients were able to return to work within 6 weeks, postoperative recovery was prolonged over several months in most of the patients. The clinical relevance of the ultrasonographic changes of the supraspinatus tendon has not yet been determined. Level IV, therapeutic case series.

  9. Imaging and simulation of Achilles tendon dynamics: Implications for walking performance in the elderly.

    PubMed

    Franz, Jason R; Thelen, Darryl G

    2016-06-14

    The Achilles tendon (AT) is a complex structure, consisting of distinct fascicle bundles arising from each triceps surae muscle that may act as mechanically independent structures. Advances in tissue imaging are rapidly accelerating our understanding of the complexities of functional Achilles tendon behavior, with potentially important implications for musculoskeletal injury and performance. In this overview of our recent contributions to these efforts, we present the results of complementary experimental and computational approaches to investigate AT behavior during walking and its potential relevance to reduced triceps surae mechanical performance due to aging. Our experimental evidence reveals that older tendons exhibit smaller differences in tissue deformations than young adults between regions of the AT presumed to arise from the gastrocnemius and soleus muscles. These observations are consistent with a reduced capacity for inter-fascicle sliding within the AT, which could have implications for the mechanical independence of the triceps surae muscles. More uniform AT deformations are also correlated with hallmark biomechanical features of elderly gait - namely, a loss of net ankle moment, power, and positive work during push-off. Simulating age-related reductions in the capacity for inter-fascicle sliding in the AT during walking predicts detriments in gastrocnemius muscle-tendon mechanical performance coupled with underlying shifts in fascicle kinematics during push-off. AT compliance, also suspected to vary due to age, systematically modulates those effects. By integrating in vivo imaging with computational modeling, we have gained theoretical insight into multi-scale biomechanical changes due to aging, hypotheses regarding their functional effects, and opportunities for experiments that validate or invalidate these assertions. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Multidisciplinary approach to the persistent double distal tendon of the biceps brachii.

    PubMed

    Blasi, Marc; de la Fuente, Javier; Martinoli, Carlo; Blasi, Juan; Pérez-Bellmunt, Albert; Domingo, Tomás; Miguel-Pérez, Maribel

    2014-01-01

    The aim of this study is to correlate the ultrasound (US) appearance of the persistent double or bifid distal tendon of the biceps brachii muscle with anatomical and histological data. This will provide a new model to study the pathological distal biceps brachii tendon (DBBT). The DBBT of 20 cadaveric elbows were examined with linear array broadband US transducers (frequency band 14-6 MHz) using an anterior approach. Trypan blue dye was injected underneath the paratenon under US guidance in 16 specimens. After they were dissected, five of them were processed to obtain histological slices stained with hematoxylin-eosin and antiserum to protein S100. At US, the DBBT is a tendon in which the fascicles are organized in two different hyperechoic components separated by a hyperechoic septum related to the endotenon. The endotenon is lax, flexible, and makes folding and gliding of the two portions feasible. The DBBT is surrounded by a hyperechoic paratenon adjacent to the tendon surface, which is only differentiable by US when dye is interposed between such structures. The connective septum of endotenon located between the two main components of the DBBT is responsible for the US image of two separate tendons and functionally enables it to work as two separate entities, thus allowing respective folding and gliding. The paratenon surrounding the lacertus fibrosus and the DBBT plays an important stabilization role, enabling them to change shape and arrangement during joint motion. It is also an important conduit for nerves and blood vessels.

  11. Tendon Adaptation to Sport-specific Loading in Adolescent Athletes.

    PubMed

    Cassel, M; Carlsohn, A; Fröhlich, K; John, M; Riegels, N; Mayer, F

    2016-02-01

    Tendon adaptation due to mechanical loading is controversially discussed. However, data concerning the development of tendon thickness in adolescent athletes is sparse. The purpose of this study was to examine possible differences in Achilles (AT) and patellar tendon (PT) thickness in adolescent athletes while considering age, gender and sport-specific loading. In 500 adolescent competitive athletes of 16 different sports and 40 recreational controls both ATs and PTs were sonographically measured. Subjects were divided into 2 age groups (< 13; ≥ 13 years) and 6 sport type categories (ball, combat, and water sports, combined disciplines, cycling, controls). In addition, 3 risk groups (low, moderate, high) were created according to the athlete's risk of developing tendinopathy. AT and PT thickness did not significantly differ between age groups (AT/PT:<13: 5.4±0.7 mm/3.6±0.5 mm;≥13: 5.3±0.7 mm/3.6±0.5 mm). In both age groups males presented higher tendon thickness than females (p<0.001). AT thickness was highest in ball sports/cyclists and lowest in controls (p≤0.002). PT thickness was greatest in water sports and lowest in controls (p=0.02). High risk athletes presented slightly higher AT thickness compared to the low risk group (p=0.03). Increased AT and PT thickness in certain sport types compared to controls supports the hypothesis of structural tendon adaptation due to sport-specific loading. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Low-Magnitude, High-Frequency Vibration Fails to Accelerate Ligament Healing but Stimulates Collagen Synthesis in the Achilles Tendon.

    PubMed

    Thompson, William R; Keller, Benjamin V; Davis, Matthew L; Dahners, Laurence E; Weinhold, Paul S

    2015-05-01

    Low-magnitude, high-frequency vibration accelerates fracture and wound healing and prevents disuse atrophy in musculoskeletal tissues. To investigate the role of low-magnitude, high-frequency vibration as a treatment to accelerate healing of an acute ligament injury and to examine gene expression in the intact Achilles tendon of the injured limb after low-magnitude, high-frequency vibration. Controlled laboratory study. Complete surgical transection of the medial collateral ligament (MCL) was performed in 32 Sprague-Dawley rats, divided into control and low-magnitude, high-frequency vibration groups. Low-magnitude, high-frequency vibration started on postoperative day 2, and rats received vibration for 30 minutes a day for 12 days. All rats were sacrificed 2 weeks after the operation, and their intact and injured MCLs were biomechanically tested or used for histological analysis. Intact Achilles tendons from the injured limb were evaluated for differences in gene expression. Mechanical testing revealed no differences in the ultimate tensile load or the structural stiffness between the control and vibration groups for either the injured or intact MCL. Vibration exposure increased gene expression of collagen 1 alpha (3-fold), interleukin 6 (7-fold), cyclooxygenase 2 (5-fold), and bone morphogenetic protein 12 (4-fold) in the intact Achilles tendon when compared with control tendons ( P < .05). While no differences were observed in the mechanical or histological properties of the fully transected MCL after low-magnitude, high-frequency vibration treatment, significant enhancements in gene expression were observed in the intact Achilles tendon. These included collagen, several inflammatory cytokines, and growth factors critical for tendons. As low-magnitude, high-frequency vibration had no negative effects on ligament healing, vibration therapy may be a useful tool to accelerate healing of other tissues (bone) in multitrauma injuries without inhibiting ligament healing. Additionally, the enhanced gene expression in response to low-magnitude, high-frequency vibration in the intact Achilles tendon suggests the need to further study its potential to accelerate tendon healing in partial injury or repair models.

  13. The supramolecular structure of bone: X-ray scattering analysis and lateral structure modeling

    PubMed Central

    Zhou, Hong-Wen; Burger, Christian; Wang, Hao; Hsiao, Benjamin S.; Chu, Benjamin; Graham, Lila

    2016-01-01

    The evolution of vertebrates required a key development in supramolecular evolution: internally mineralized collagen fibrils. In bone, collagen molecules and mineral crystals form a nanocomposite material comparable to cast iron in tensile strength, but several times lighter and more flexible. Current understanding of the internal nanoscale structure of collagen fibrils, derived from studies of rat tail tendon (RTT), does not explain how nucleation and growth of mineral crystals can occur inside a collagen fibril. Experimental obstacles encountered in studying bone have prevented a solution to this problem for several decades. This report presents a lateral packing model for collagen molecules in bone fibrils, based on the unprecedented observation of multiple resolved equatorial reflections for bone tissue using synchrotron small-angle X-ray scattering (SAXS; ∼1 nm resolution). The deduced structure for pre-mineralized bone fibrils includes features that are not present in RTT: spatially discrete microfibrils. The data are consistent with bone microfibrils similar to pentagonal Smith microfibrils, but are not consistent with the (nondiscrete) quasi-hexagonal microfibrils reported for RTT. These results indicate that collagen fibrils in bone and tendon differ in their internal structure in a manner that allows bone fibrils, but not tendon fibrils, to internally mineralize. In addition, the unique pattern of collagen cross-link types and quantities in mineralized tissues can be can be accounted for, in structural/functional terms, based on a discrete microfibril model. PMID:27599731

  14. Gross anatomical and dimensional characteristics of the proximal hamstring origin.

    PubMed

    Feucht, Matthias J; Plath, Johannes E; Seppel, Gernot; Hinterwimmer, Stefan; Imhoff, Andreas B; Brucker, Peter U

    2015-09-01

    The current study was undertaken to better define the gross anatomical and dimensional characteristics of the proximal hamstring origin. Twelve paired whole-lower extremities from six embalmed cadavers were dissected. The gross anatomy of the proximal hamstrings was studied. With the tendons attached to the ischial tuberosity, the width and thickness of each tendon was measured 1 cm distally to their origin, and the distance from the most proximal border of the common origin of the semitendinosus (ST) and long head of the biceps (LB) to their distal junction was assessed. After removal of the hamstring group, the shape, orientation, and dimension of the tendon footprints were determined. One cadaver demonstrated unique anatomy, which was considered as an anatomic variant and was therefore excluded from the study group. The ST and LB had a common origin on the posterolateral aspect of the ischial tuberosity (ST/LB), whereas the semimembranosus (SM) had a separated origin at the anterolateral aspect. The mean distance from the most proximal border of the ST/LB origin to the distal junction was 10.0 ± 1.3 cm. The shape of both footprints was longitudinal-oval, with the longitudinal axes of the SM and ST/LB footprints parallel aligned. Mean tendon width was 3.4 ± 0.5 cm for the common ST/LB complex and 4.2 ± 0.9 cm for the SM (p = 0.009). The corresponding values for tendon thickness were 1.0 ± 0.3 cm (ST/LB) and 0.8 ± 0.2 cm (SM), respectively (n.s.). Mean footprint length was 3.9 ± 0.4 cm for ST/LB and 4.5 ± 0.5 cm for SM (p = 0.002). The corresponding values for footprint height were 1.4 ± 0.5 cm (ST/LB) and 1.2 ± 0.3 cm (SM), respectively (n.s.). The ST and LB had a common origin, whereas the SM originated separately. The site of origin of both tendons was the lateral aspect of the ischial tuberosity, with the SM footprint lying directly anterior to the footprint of the ST/LB complex. The footprint of the SM was significantly wider than the footprint of the ST/LB. The reported gross anatomic findings and dimensions may aid surgeons in anchor placement at the anatomical attachment site, thereby facilitating anatomic hamstring repair. In addition, the provided data may improve diagnosis and conservative treatment of proximal hamstring tendinopathy, since detailed knowledge about the normal anatomy is crucial for recognizing tendon abnormalities and for several conservative treatment modalities such as shockwave application or ultrasound-guided injections.

  15. Ligamentization of tendon grafts treated with an endogenous preparation rich in growth factors: gross morphology and histology.

    PubMed

    Sánchez, Mikel; Anitua, Eduardo; Azofra, Juan; Prado, Roberto; Muruzabal, Francisco; Andia, Isabel

    2010-04-01

    To investigate whether the application of a particular platelet-rich plasma preparation rich in growth factors (PRGF) during anterior cruciate ligament (ACL) surgery gives a potential advantage for better tendon graft ligamentization. This study included 37 volunteers who underwent either conventional (control group, n = 15) or PRGF-assisted (n = 22) ACL reconstruction with an autogenous hamstring and required second-look arthroscopy to remove hardware or loose bodies, treat meniscal tears or plica syndrome, or resect cyclops lesions at 6 to 24 months after ACL surgery. The gross morphologies of the grafts were evaluated on second-look arthroscopy by use of the full arthroscopic score (0 to 4 points) to evaluate graft thickness and apparent tension (0 to 2 points) plus synovial coverage (0 to 2 points). At the same time, biopsy specimens were harvested uniformly from the grafted tendons. In these specimens the histologic transformation of the tendon graft to ACL-like tissue was evaluated by use of the Ligament Tissue Maturity Index, and a score to assess the progression of new connective tissue enveloping the graft was created by use of 3 criteria previously used to characterize changes during ligament healing: cellularity, vascularity, and collagen properties. The overall arthroscopic evaluation of PRGF-treated grafts showed an excellent rating in 57.1% of the knees (score of 4) and a fair rating in 42.9% (score of 2 or 3). In contrast, evaluation of untreated grafts showed an excellent rating in 33.3% of the knees, a fair rating in 46.7%, and a poor rating in 20% (score of 0 or 1). Overall, arthroscopic evaluations were not statistically different between PRGF and control groups (P = .051). PRGF treatment influenced the histologic characteristics of the tendon graft, resulting in tissue that was more mature than in controls (P = .024). Histologically evident newly formed connective tissue enveloping the graft was present in 77.3% of PRGF-treated grafts and 40% of controls. The appearance of the connective tissue envelope changed with increasing time from surgery. On the basis of the histologic findings, we suggest that the remodeling of PRGF-treated grafts involves the formation of synovial-like tissue enveloping the graft. This tissue is eventually integrated in the remodeled tendon graft, conferring a similar appearance to the normal ACL. The use of PRGF influenced the histologic characteristics of tendon grafts, resulting in more remodeling compared with untreated grafts. We have shown temporal histologic changes during the 6- to 24-month postoperative period of graft maturation, with newly formed connective tissue enveloping most grafts treated with PRGF. Level III, case-control study. Copyright 2010 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  16. The anatomical and imaging study of pes anserinus and its clinical application

    PubMed Central

    Zhong, Sheng; Wu, Bo; Wang, Miao; Wang, Xiaohong; Yan, Qi; Fan, Xingyu; Hu, Yanmei; Han, Yingying; Li, Youqiong

    2018-01-01

    Abstract Background: The pes anserinus was an important graft choice for anterior cruciate ligament (ACL) reconstruction. The infrapatellar branch of the saphenous nerve (IPBSN) might be damaged in this surgery. This study aimed to provide anatomic and ultrasonic measurement data of pes anserinus and superficial nerves. Methods: Eighty lower limb specimens of forty adult cadavers were dissected. The length, width, thickness, and the position of the tibial attachment of pes anserinus tendons were anthropometric measured, as well as the distance between the infrapatellar branch of the saphenous nerve and the pes anserinus. Sixty healthy adult participants were enrolled for ultrasonic research. The length, width, thickness of pes anserinus was also measured and the saphenous nerve was also assessed. Results: Anatomic results showed that there were 3 types of pes anserinus, the infrapatellar branch of the saphenous nerve (IPBSN) was almost paralleled to the upper edge of the pes anserinus tendon, and the average of distance between them was about 0.95 cm. The length of semitendinosus and gracilis tendons were 146.49 ± 12.83 mm and 124.62 ± 8.86 mm, the width of sartorius tendon was 25.58 ± 4.65 mm, wider than other tendons. The classification of pes anserinus tendons and the saphenous nerves could be identified in ultrasonic image. The length of semitendinosus and gracilis tendons were 151.35 ± 9.65 mm and 120.86 ± 8.99 mm, the width of sartorius tendon was 22.84 ± 3.83 mm. And there was no significance difference between anatomic and ultrasonic measurement (P > .05). Conclusion: The morphology of pes anserinus and its peripheral structures could be identified and measured precisely by ultrasound device, a presurgical ultrasonic examination was recommended. The arrangement of pes anserinus tendons was classified into 3 types according to our results. The incision should be performed medial to tibial eminence 1.5 cm and under the tibial tubercle level 2 to 3 cm, an oblique incision formed an angle of 50° with tibial transection was recommend, which was parallel to the direction of pes anserinus tendon. PMID:29642176

  17. The collagen structure of equine articular cartilage, characterized using polarization-sensitive optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Ugryumova, Nadya; Attenburrow, Don P.; Winlove, C. Peter; Matcher, Stephen J.

    2005-08-01

    Optical coherence tomography and polarization-sensitive optical coherence tomography images of equine articular cartilage are presented. Measurements were made on intact joint surfaces. Significant (e.g. × 2) variations in the intrinsic birefringence were found over spatial scales of a few millimetres, even on samples taken from young (18 month) animals that appeared visually homogeneous. A comparison of data obtained on a control tissue (equine flexor tendon) further suggests that significant variations in the orientation of the collagen fibres relative to the plane of the joint surface exist. Images of visually damaged cartilage tissue show characteristic features both in terms of the distribution of optical scatterers and of the birefringent components.

  18. Basic radiological assessment of synovial diseases: a pictorial essay

    PubMed Central

    Turan, Aynur; Çeltikçi, Pınar; Tufan, Abdurrahman; Öztürk, Mehmet Akif

    2017-01-01

    The synovium is a specialized tissue lining the synovial joints, bursae, and tendon sheaths of the body. It is affected by various localized or systemic disorders. Synovial diseases can be classified as inflammatory, infectious, degenerative, traumatic, hemorrhagic, and neoplastic. Damage in other intraarticular structures, particularly cartilages, generally occurs as a part of pathologic processes involving the synovium, leading to irreversible joint destruction. Imaging has an essential role in the early detection of synovial diseases prior to irreversible joint damage. Obtaining and understanding characteristic imaging findings of synovial diseases enables a proper diagnosis for early treatment. This article focuses on the recent literature that is related with the role of imaging in synovial disease. PMID:28638696

  19. Joint capsule attachment to the extensor carpi radialis brevis origin: an anatomical study with possible implications regarding the etiology of lateral epicondylitis.

    PubMed

    Nimura, Akimoto; Fujishiro, Hitomi; Wakabayashi, Yoshiaki; Imatani, Junya; Sugaya, Hiroyuki; Akita, Keiichi

    2014-02-01

    To identify the unique anatomical characteristic of the extensor carpi radialis brevis (ECRB) origin and points of differentiation from other extensors and to clarify the specific relationship of the ECRB to the underlying structures. We studied the origin of each extensor macroscopically for its muscular and tendinous parts; to identify the relationship between the ECRB origin and the deeper structures, we also examined the attachment of the joint capsule under the ECRB origin. The ECRB simply originated as a tendon without any muscle, whereas other extensors originated as a mixture of tendon and muscle. At the anterior part of the ECRB origin, the thin attachment of the joint capsule (average width, 3.3 mm) lay deep to the ECRB and was distinct. However, at the posterodistal portion, the joint capsule, annular ligament, and supinator were intermingled and originated as a single wide sheet from the humerus (average width, 10.7 mm). The anterior part of the ECRB origin was delicate, because the ECRB origin was purely tendinous, and the attachment of the articular capsule was thin compared with that of the posterodistal attachment. This thin attachment could be an initial factor leading to the development of lateral epicondylitis. The results of the current study may enhance magnetic resonance imaging understanding and may help clarify the etiology of the lateral epicondylitis. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  20. Regenerative Medicine in Rotator Cuff Injuries

    PubMed Central

    Randelli, Pietro; Ragone, Vincenza; Menon, Alessandra; Cabitza, Paolo; Banfi, Giuseppe

    2014-01-01

    Rotator cuff injuries are a common source of shoulder pathology and result in an important decrease in quality of patient life. Given the frequency of these injuries, as well as the relatively poor result of surgical intervention, it is not surprising that new and innovative strategies like tissue engineering have become more appealing. Tissue-engineering strategies involve the use of cells and/or bioactive factors to promote tendon regeneration via natural processes. The ability of numerous growth factors to affect tendon healing has been extensively analyzed in vitro and in animal models, showing promising results. Platelet-rich plasma (PRP) is a whole blood fraction which contains several growth factors. Controlled clinical studies using different autologous PRP formulations have provided controversial results. However, favourable structural healing rates have been observed for surgical repair of small and medium rotator cuff tears. Cell-based approaches have also been suggested to enhance tendon healing. Bone marrow is a well known source of mesenchymal stem cells (MSCs). Recently, ex vivo human studies have isolated and cultured distinct populations of MSCs from rotator cuff tendons, long head of the biceps tendon, subacromial bursa, and glenohumeral synovia. Stem cells therapies represent a novel frontier in the management of rotator cuff disease that required further basic and clinical research. PMID:25184132

  1. Effect of fiber distribution and realignment on the nonlinear and inhomogeneous mechanical properties of human supraspinatus tendon under longitudinal tensile loading.

    PubMed

    Lake, Spencer P; Miller, Kristin S; Elliott, Dawn M; Soslowsky, Louis J

    2009-12-01

    Tendon exhibits nonlinear stress-strain behavior that may be partly due to movement of collagen fibers through the extracellular matrix. While a few techniques have been developed to evaluate the fiber architecture of other soft tissues, the organizational behavior of tendon under load has not been determined. The supraspinatus tendon (SST) of the rotator cuff is of particular interest for investigation due to its complex mechanical environment and corresponding inhomogeneity. In addition, SST injury occurs frequently with limited success in treatment strategies, illustrating the need for a better understanding of SST properties. Therefore, the objective of this study was to quantitatively evaluate the inhomogeneous tensile mechanical properties, fiber organization, and fiber realignment under load of human SST utilizing a novel polarized light technique. Fiber distributions were found to become more aligned under load, particularly during the low stiffness toe-region, suggesting that fiber realignment may be partly responsible for observed nonlinear behavior. Fiber alignment was found to correlate significantly with mechanical parameters, providing evidence for strong structure-function relationships in tendon. Human SST exhibits complex, inhomogeneous mechanical properties and fiber distributions, perhaps due to its complex loading environment. Surprisingly, histological grade of degeneration did not correlate with mechanical properties.

  2. Longitudinal Long-term Magnetic Resonance Imaging and Clinical Follow-up After Single-Row Arthroscopic Rotator Cuff Repair: Clinical Superiority of Structural Tendon Integrity.

    PubMed

    Heuberer, Philipp R; Smolen, Daniel; Pauzenberger, Leo; Plachel, Fabian; Salem, Sylvia; Laky, Brenda; Kriegleder, Bernhard; Anderl, Werner

    2017-05-01

    The number of arthroscopic rotator cuff surgeries is consistently increasing. Although generally considered successful, the reported number of retears after rotator cuff repair is substantial. Short-term clinical outcomes are reported to be rarely impaired by tendon retears, whereas to our knowledge, there is no study documenting long-term clinical outcomes and tendon integrity after arthroscopic rotator cuff repair. To investigate longitudinal long-term repair integrity and clinical outcomes after arthroscopic rotator cuff reconstruction. Case series; Level of evidence, 4. Thirty patients who underwent arthroscopic rotator cuff repair with suture anchors for a full-tendon full-thickness tear of the supraspinatus or a partial-tendon full-thickness tear of the infraspinatus were included. Two and 10 years after initial arthroscopic surgery, tendon integrity was analyzed using magnetic resonance imaging (MRI). The University of California, Los Angeles (UCLA) score and Constant score as well as subjective questions regarding satisfaction with the procedure and return to normal activity were used to evaluate short- and long-term outcomes. At the early MRI follow-up, 42% of patients showed a full-thickness rerupture, while 25% had a partial rerupture, and 33% of tendons remained intact. The 10-year MRI follow-up (129 ± 11 months) showed 50% with a total rerupture, while the other half of the tendons were partially reruptured (25%) or intact (25%). The UCLA and Constant scores significantly improved from preoperatively (UCLA total: 50.6% ± 20.2%; Constant total: 44.7 ± 10.5 points) to 2 years (UCLA total: 91.4% ± 16.0% [ P < .001]; Constant total: 87.8 ± 15.3 points [ P < .001]) and remained significantly higher after 10 years (UCLA total: 89.7% ± 15.9% [ P < .001]; Constant total: 77.5 ± 15.6 points [ P < .001]). The Constant total score and Constant strength subscore, but not the UCLA score, were also significantly better at 10 years postoperatively in patients with intact tendons compared with patients with retorn tendons (Constant total: 89.0 ± 7.8 points vs 75.7 ± 14.1 points, respectively [ P = .034]; Constant strength: 18.0 ± 4.9 points vs 9.2 ± 5.2 points, respectively [ P = .006]). The majority of patients rated their satisfaction with the procedure as "excellent" (83.3%), and 87.5% returned to their normal daily activities. Arthroscopic rotator cuff repair showed good clinical long-term results despite a high rate of retears. Nonetheless, intact tendons provided significantly superior clinical long-term outcomes, making the improvement of tendon healing and repair integrity important goals of future research efforts.

  3. Sonographic differentiation of digital tendon rupture from adhesive scarring after primary surgical repair.

    PubMed

    Budovec, Joseph J; Sudakoff, Gary S; Dzwierzynski, William W; Matloub, Hani S; Sanger, James R

    2006-04-01

    After the surgical repair of finger tendons finger range of motion may be limited by tendon rupture or adhesive scarring. Differentiating tendon rupture from adhesive scarring may be difficult clinically. Digital tendon sonography allows the evaluation of tendon integrity in a dynamic setting. Our objective was to determine if sonography could differentiate tendon rupture from adhesive scarring in patients who have had primary tendon repair. A retrospective review was performed of the radiographic, clinical, and surgical records of patients referred for finger sonography over a 2-year period. Twenty-eight digits in 21 patients were evaluated for finger tendon disruption after primary surgical repair. The diagnosis of complete tendon rupture was made when 1 or more of the following was identified: a gap separating the proximal and distal tendon margins, visualization of only the proximal tendon margin, or visualization of only the distal tendon margin. Adhesive scarring was diagnosed if the tendon appeared intact with abnormal peritendinous soft tissue abutting or partially encasing the tendon, with synovial sheath thickening, or with restricted tendon motion during dynamic evaluation. Sonography correctly identified tendon rupture or adhesive scarring in 27 of 28 digits with 1 false-positive case (sensitivity, 100%; specificity, 93%; positive-predictive value, 93%; negative-predictive value, 100%; accuracy, 96%). Sonography is an accurate modality for differentiating tendon rupture from adhesive scarring in patients with prior surgical tendon repair. Diagnostic, Level I.

  4. rhPDGF-BB promotes early healing in a rat rotator cuff repair model.

    PubMed

    Kovacevic, David; Gulotta, Lawrence V; Ying, Liang; Ehteshami, John R; Deng, Xiang-Hua; Rodeo, Scott A

    2015-05-01

    Tendon-bone healing after rotator cuff repair occurs by fibrovascular scar tissue formation, which is weaker than a normal tendon-bone insertion site. Growth factors play a role in tissue formation and have the potential to augment soft tissue healing in the perioperative period. Our study aim was to determine if rhPDGF-BB delivery on a collagen scaffold can improve tendon-to-bone healing after supraspinatus tendon repair compared with no growth factor in rats as measured by (1) gross observations; (2) histologic analysis; and (3) biomechanical testing. Ninety-five male Sprague-Dawley rats underwent acute repair of the supraspinatus tendon. Rats were randomized into one of five groups: control (ie, repair only), scaffold only, and three different platelet-derived growth factor (PDGF) doses on the collagen scaffold. Animals were euthanized 5 days after surgery to assess cellular proliferation and angiogenesis. The remaining animals were analyzed at 4 weeks to assess repair site integrity by gross visualization, fibrocartilage formation with safranin-O staining, and collagen fiber organization with picrosirius red staining, and to determine the biomechanical properties (ie, load-to-failure testing) of the supraspinatus tendon-bone construct. The repaired supraspinatus tendon was in continuity with the bone in all animals. At 5 days, rhPDGF-BB delivery on a scaffold demonstrated a dose-dependent response in cellular proliferation and angiogenesis compared with the control and scaffold groups. At 28 days, with the numbers available, rhPDGF-BB had no effect on increasing fibrocartilage formation or improving collagen fiber maturity at the tendon-bone insertion site compared with controls. The control group had higher tensile loads to failure and stiffness (35.5 ± 8.8 N and 20.3 ± 4.5 N/mm) than all the groups receiving the scaffold, including the PDGF groups (scaffold: 27 ± 6.4 N, p = 0.021 and 13 ± 5.7 N/mm, p = 0.01; 30 µg/mL PDGF: 26.5 ± 7.5 N, p = 0.014 and 13.3 ± 3.2 N/mm, p = 0.01; 100 µg/mL PDGF: 25.7 ± 6.1 N, p = 0.005 and 11.6 ± 3.3 N/mm, p = 0.01; 300 µg/mL PDGF: 27 ± 6.9 N, p = 0.014 and 12.7 ± 4.1 N/mm, p = 0.01). rhPDGF-BB delivery on a collagen scaffold enhanced cellular proliferation and angiogenesis during the early phase of healing, but this did not result in either a more structurally organized or stronger attachment site at later stages of healing. The collagen scaffold had a detrimental effect on healing strength at 28 days, and its relatively larger size compared with the rat tendon may have caused mechanical impingement and extrinsic compression of the healing tendon. Future studies should be performed in larger animal models where healing occurs more slowly. Augmenting the healing environment to improve the structural integrity and to reduce the retear rate after rotator cuff repair may be realized with continued understanding and optimization of growth factor delivery systems.

  5. Step Cut Lengthening: A Technique for Treatment of Flexor Pollicis Longus Tendon Rupture.

    PubMed

    Chong, Chew-Wei; Chen, Shih-Heng

    2018-04-01

    Reconstruction of a tendon defect is a challenging task in hand surgery. Delayed repair of a ruptured flexor pollicis longus (FPL) tendon is often associated with tendon defect. Primary repair of the tendon is often not possible, particularly after debridement of the unhealthy segment of the tendon. As such, various surgical treatments have been described in the literature, including single-stage tendon grafting, 2-stage tendon grafting, flexor digitorum superficialis tendon transfer from ring finger, and interphalangeal joint arthrodesis. We describe step cut lengthening of FPL tendon for the reconstruction of FPL rupture. This is a single-stage reconstruction without the need for tendon grafting or tendon transfer. To our knowledge, no such technique has been previously described.

  6. Tendon transfer fixation: comparing a tendon to tendon technique vs. bioabsorbable interference-fit screw fixation.

    PubMed

    Sabonghy, Eric Peter; Wood, Robert Michael; Ambrose, Catherine Glauber; McGarvey, William Christopher; Clanton, Thomas Oscar

    2003-03-01

    Tendon transfer techniques in the foot and ankle are used for tendon ruptures, deformities, and instabilities. This fresh cadaver study compares the tendon fixation strength in 10 paired specimens by performing a tendon to tendon fixation technique or using 7 x 20-25 mm bioabsorbable interference-fit screw tendon fixation technique. Load at failure of the tendon to tendon fixation method averaged 279N (Standard Deviation 81N) and the bioabsorbable screw 148N (Standard Deviation 72N) [p = 0.0008]. Bioabsorbable interference-fit screws in these specimens show decreased fixation strength relative to the traditional fixation technique. However, the mean bioabsorbable screw fixation strength of 148N provides physiologic strength at the tendon-bone interface.

  7. A comparative analysis of the encapsulated end-organs of mammalian skeletal muscles and of their sensory nerve endings.

    PubMed

    Banks, R W; Hulliger, M; Saed, H H; Stacey, M J

    2009-06-01

    The encapsulated sensory endings of mammalian skeletal muscles are all mechanoreceptors. At the most basic functional level they serve as length sensors (muscle spindle primary and secondary endings), tension sensors (tendon organs), and pressure or vibration sensors (lamellated corpuscles). At a higher functional level, the differing roles of individual muscles in, for example, postural adjustment and locomotion might be expected to be reflected in characteristic complements of the various end-organs, their sensory endings and afferent nerve fibres. This has previously been demonstrated with regard to the number of muscle-spindle capsules; however, information on the other types of end-organ, as well as the complements of primary and secondary endings of the spindles themselves, is sporadic and inconclusive regarding their comparative provision in different muscles. Our general conclusion that muscle-specific variability in the provision of encapsulated sensory endings does exist demonstrates the necessity for the acquisition of more data of this type if we are to understand the underlying adaptive relationships between motor control and the structure and function of skeletal muscle. The present quantitative and comparative analysis of encapsulated muscle afferents is based on teased, silver-impregnated preparations. We begin with a statistical analysis of the number and distribution of muscle-spindle afferents in hind-limb muscles of the cat, particularly tenuissimus. We show that: (i) taking account of the necessity for at least one primary ending to be present, muscles differ significantly in the mean number of additional afferents per spindle capsule; (ii) the frequency of occurrence of spindles with different sensory complements is consistent with a stochastic, rather than deterministic, developmental process; and (iii) notwithstanding the previous finding, there is a differential distribution of spindles intramuscularly such that the more complex ones tend to be located closer to the main divisions of the nerve. Next, based on a sample of tendon organs from several hind-foot muscles of the cat, we demonstrate the existence in at least a large proportion of tendon organs of a structural substrate to account for multiple spike-initiation sites and pacemaker switching, namely the distribution of sensory terminals supplied by the different first-order branches of the Ib afferent to separate, parallel, tendinous compartments of individual tendon organs. We then show that the numbers of spindles, tendon organs and paciniform corpuscles vary independently in a sample of (mainly) hind-foot muscles of the cat. Grouping muscles by anatomical region in the cat indicated the existence of a gradual proximo-distal decline in the overall average size of the afferent complement of muscle spindles from axial through hind limb to intrinsic foot muscles, but with considerable muscle-specific variability. Finally, we present some comparative data on muscle-spindle afferent complements of rat, rabbit and guinea pig, one particularly notable feature being the high incidence of multiple primary endings in the rat.

  8. Multidimensional Ultrasound Imaging of the Wrist: Changes of Shape and Displacement of the Median Nerve and Tendons in Carpal Tunnel Syndrome

    PubMed Central

    Filius, Anika; Scheltens, Marjan; Bosch, Hans G.; van Doorn, Pieter A.; Stam, Henk J.; Hovius, Steven E.R.; Amadio, Peter C.; Selles, Ruud W.

    2015-01-01

    Dynamics of structures within the carpal tunnel may alter in carpal tunnel syndrome (CTS) due to fibrotic changes and increased carpal tunnel pressure. Ultrasound can visualize these potential changes, making ultrasound potentially an accurate diagnostic tool. To study this, we imaged the carpal tunnel of 113 patients and 42 controls. CTS severity was classified according to validated clinical and nerve conduction study (NCS) classifications. Transversal and longitudinal displacement and shape (changes) were calculated for the median nerve, tendons and surrounding tissue. To predict diagnostic value binary logistic regression modeling was applied. Reduced longitudinal nerve displacement (p≤0.019), increased nerve cross-sectional area (p≤0.006) and perimeter (p≤0.007), and a trend of relatively changed tendon displacements were seen in patients. Changes were more convincing when CTS was classified as more severe. Binary logistic modeling to diagnose CTS using ultrasound showed a sensitivity of 70-71% and specificity of 80-84%. In conclusion, CTS patients have altered dynamics of structures within the carpal tunnel. PMID:25865180

  9. Coherent X-Ray Imaging of Collagen Fibril Distributions within Intact Tendons

    PubMed Central

    Berenguer, Felisa; Bean, Richard J.; Bozec, Laurent; Vila-Comamala, Joan; Zhang, Fucai; Kewish, Cameron M.; Bunk, Oliver; Rodenburg, John M.; Robinson, Ian K.

    2014-01-01

    The characterization of the structure of highly hierarchical biosamples such as collagen-based tissues at the scale of tens of nanometers is essential to correlate the tissue structure with its growth processes. Coherent x-ray Bragg ptychography is an innovative imaging technique that gives high resolution images of the ordered parts of such samples. Herein, we report how we used this method to image the collagen fibrillar ultrastructure of intact rat tail tendons. The images show ordered fibrils extending over 10–20 μm in length, with a quantifiable D-banding spacing variation of 0.2%. Occasional defects in the fibrils distribution have also been observed, likely indicating fibrillar fusion events. PMID:24461021

  10. Incidence and Association of CT Findings of Ankle Tendon Injuries in Patients Presenting With Ankle and Hindfoot Fractures.

    PubMed

    Golshani, Ashkahn; Zhu, Liang; Cai, Chunyan; Beckmann, Nicholas M

    2017-02-01

    Tendon injuries are a commonly encountered finding in ankle CT examinations performed for fractures. This study was designed to identify the incidence and associations of tendon injuries in ankle CT examinations performed for fractures. A retrospective review was performed of 410 patients who underwent ankle CT during a 6-year period. Tendon injuries were common, seen in 25% of all ankle CT examinations. Tendon subluxation-dislocation accounted for most of the tendon injuries (77 of 196 total injuries). Pilon fractures carried 2.2 times increased risk of tibialis posterior tendon injury (p = 0.0094). Calcaneus fractures carried 11.86 times increased risk of peroneus brevis tendon and 10.71 times increased risk of peroneus longus tendon injury (p < 0.0001). Calcaneus fractures also carried 5.21 times increased risk of flexor hallucis longus tendon injury (p = 0.0024). Talus fracture was associated with injury to all flexor compartment tendons. Talus fractures carried 3.43 times increased risk of tibialis posterior tendon injury (p < 0.0001), 4.51 times increased risk of flexor digitorum longus tendon injury (p = 0.0005), and 6.97 times increased risk of flexor hallucis longus tendon injury (p < 0.0001). Calcaneal fractures are prone to peroneal tendon injury, and talus fractures are prone to flexor tendon injury. In patients with pilon fractures, it is important to look for tibialis posterior tendon injury, specifically for entrapment. Overall, the most common type of injury is tendon malalignment, so it is imperative to know the normal tendon paths and associated bony landmarks to identify tendon injury.

  11. Plyometric vs. isometric training influences on tendon properties and muscle output.

    PubMed

    Burgess, Katherine E; Connick, Mark J; Graham-Smith, Philip; Pearson, Stephen J

    2007-08-01

    The purpose of this study was to concurrently determine the effect that plyometric and isometric training has on tendon stiffness (K) and muscle output characteristics to compare any subsequent changes. Thirteen men trained the lower limbs either plyometrically or isometrically 2-3 times a week for a 6-week period. Medial gastrocnemius tendon stiffness was measured in vivo using ultrasonography during ramped isometric contractions before and after training. Mechanical output variables were measured using a force plate during concentric and isometric efforts. Significant (p < 0.05) training-induced increases in tendon K were seen for the plyometric (29.4%; 49.0 +/- 10.8 to 63.4 +/- 9.2 N x mm(-1)) and isometric groups (61.6%; 43.9 +/- 2.5 to 71.0 +/- 7.4 N x mm(-1)). Statistically similar increases in rate of force development and jump height were also seen for both training groups, with increases of 18.9 and 58.6% for the plyometric group and 16.7 and 64.3% for the isometric group, respectively. Jump height was found to be significantly correlated with tendon stiffness, such that stiffness could explain 21% of the variance in jump height. Plyometric training has been shown to place large stresses on the body, which can lead to a potential for injury, whereas explosive isometric training has been shown here to provide similar benefits to that of plyometric training with respect to the measured variables, but with reduced impact forces, and would therefore provide a useful adjunct for athletic training programs within a 6-week time frame.

  12. Should the annular tendon of the eye be named 'annulus of Zinn' or 'of Valsalva'?

    PubMed

    Zampieri, Fabio; Marrone, Daniela; Zanatta, Alberto

    2015-02-01

    The annular tendon is commonly named 'annulus of Zinn', from the German anatomist and botanist Johann Gottfried Zinn (1727-1759) who described this structure in his Descriptio anatomica oculi humani (Anatomical Description of the Human Eye, 1755). This structure, however, had been previously discovered not by Zinn, but by Antonio Maria Valsalva (1666-1723) some decades before the publication of Zinn, in his Dissertatio anatomica prima and Dissertatio anatomica altera (First and Second Anatomical Dissertations), inside Valsalva's Opera omnia published in 1740. We advance that this structure could be re-named such as 'annulus of Valsalva-Zinn' because Valsalva, even making a mistake in its functional interpretation, first described this anatomical structure. Likewise, Valsalva, with his discovery, advanced a revolutionary idea for that time on the usefulness of anatomy for clinic and pathology. © 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  13. Objective assessment of surgical training in flexor tendon repair: the utility of a low-cost porcine model as demonstrated by a single-subject research design.

    PubMed

    Zetlitz, Elisabeth; Wearing, Scott Cameron; Nicol, Alexander; Hart, Andrew Mackay

    2012-01-01

    This study evaluated the utility of a porcine flexor tendon model and standard biomechanical testing procedures to quantify the acquisition of surgical skills associated with Zone II flexor tendon repair in a trainee by benchmarking task performance outcomes relative to evidence-based standards. Single-subject repeated measures research design. Bench-top set-up of apparatus undertaken in a University Research laboratory. After initial directed learning, a trainee repaired 70 fresh flexor digitorum profundus tendons within the flexor sheath using either a Pennington or ventral-locking-loop modification of a two-strand Kessler core repair. Tendon repairs were then preconditioned and distracted to failure. Key biomechanical parameters of the repair, including the ultimate tensile strength (UTS), yield strength, 3 mm gap force and stiffness, were calculated. Repairs were divided into 3 categories, early (first 10 days), intermediate (ensuing 10 days), and late repairs (final 10 days), and potential changes in repair properties over the training period were evaluated using a general linear modeling approach. There was a significant change in the mechanical characteristics of the repairs over the training period, evidencing a clear learning effect (p < 0.05). Irrespective of the repair technique employed, early and intermediate repairs were characterized by a significantly lower UTS (29% and 20%, respectively), 3 mm gap (21% and 16%, respectively), and yield force (18% and 23%, respectively), but had a higher stiffness (33% and 38%, respectively) than late repairs (p < 0.05). The UTS of late repairs (47-48 N) were comparable to those published within the literature (45-51 N), suggesting surgical competence of the trainee. This simple, low-cost porcine model appears to be useful for providing preclinical training in flexor tendon repair techniques and has the potential to provide a quantitative index to evaluate the competency of surgical trainees. Further research is now required to identify optimal training parameters for flexor tendon repair and to develop procedure-specific standards for adequate benchmarking. Copyright © 2012 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  14. Biomechanical effects of a 2 suture-pass medial inter-implant mattress on transosseous-equivalent rotator cuff repair and considerations for a "technical efficiency ratio".

    PubMed

    Park, Maxwell C; Peterson, Alexander; Patton, John; McGarry, Michelle H; Park, Chong J; Lee, Thay Q

    2014-03-01

    Rotator cuff repair involving fewer tendon suture passes without compromising biomechanical performance would represent a technical advancement. An inter-implant "medial pulley-mattress" transosseous-equivalent (MP-TOE) repair requiring fewer tendon suture-passes was hypothesized to provide equivalent biomechanical characteristics compared to the control. In 6 human cadaveric shoulders, a transosseous-equivalent (TOE) repair (control) was performed utilizing 2 separate medial mattresses resulting in 4 tendon-bridging sutures. In 6 matched-pairs, 2 single-loaded anchors were used to create a medial inter-implant mattress construct (all sutures shuttled in 1 tendon pass per anchor)-after knot-tying, the same tendon-bridging pattern as the control was created. A materials testing machine cyclically loaded each repair from 10-180 N for 30 cycles; each repair subsequently underwent failure testing. Gap and strain were measured with a video digitizing system. A "technical efficiency ratio" (TER) was defined as: (#knots + #suture passes + #suture limbs)/#fixation points. Cyclic and failure testing demonstrated no significant differences between constructs. Gap formation at cycle 30 was 5.3 ± 0.8 mm (TOE) and 5.0 ± 0.3 mm (MP-TOE) (P = .62). Cycle 30 anterior strain values were -16.0 ± 7.3% (TOE) and -15.8 ± 6.6% (MP-TOE) (P = .99). Yield loads were 208.7 ± 2.7 N (TOE) and 204.0 ± 1.3 N (MP-TOE) (P = .17). Mode of failure demonstrated less tendon cut-out with the MP-TOE repair. The MP-TOE repair has a TER of 2.0 vs 2.5 for the control. The MP-TOE repair requiring fewer tendon suture passes, yet creating an additional inter-implant mattress configuration, is biomechanically equivalent to the original TOE technique, and may limit failure with improved medial load-sharing capacity. A TER may help quantify technical ease and help standardize comparisons between repair techniques. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.

  15. Characterization and Surgical Management of Achilles Tendon Sleeve Avulsions.

    PubMed

    Huh, Jeannie; Easley, Mark E; Nunley, James A

    2016-06-01

    An Achilles sleeve avulsion occurs when the tendon ruptures distally from its calcaneal insertion as a continuous "sleeve." This relatively rare injury pattern may not be appreciated until the time of surgery and can be challenging to treat because, unlike a midsubstance rupture, insufficient tendon remains on the calcaneus to allow for end-to-end repair, and unlike a tuberosity avulsion fracture, any bony element avulsed with the tendon is inadequate for internal fixation. This study aimed to highlight the characteristics of Achilles sleeve avulsions and present the outcomes of operative repair using suture anchor fixation. A retrospective analysis was conducted on 11 consecutive Achilles tendon sleeve avulsions (10 males, 1 female; mean age 44 years) that underwent operative repair between 2008 and 2014. Patient demographics, injury presentation, and operative details were reviewed. Postoperative outcomes were collected at a mean follow-up of 38.4 (range, 12-83.5) months, including the American Orthopaedic Foot & Ankle Society (AOFAS) Ankle-Hindfoot score, visual analog scale (VAS) for pain, plantarflexion strength, patient satisfaction, and complications. Eight patients (72.7%) had preexisting symptoms of insertional Achilles disease. Ten of 11 (90.9%) injuries were sustained during recreational athletic activity. An Achilles sleeve avulsion was recognized preoperatively in 7 of 11 (64%) cases, where lateral ankle radiographs demonstrated a small radiodensity several centimeters proximal to the calcaneal insertion. Intraoperatively, 90.9% of sleeve avulsions had a concomitant Haglund deformity and macroscopic evidence of insertional tendinopathy. All patients healed after suture anchor repair. The average AOFAS score was 92.8 and VAS score was 0.9. Ten patients (90.9%) were completely satisfied. One complication occurred, consisting of delayed wound healing. Achilles tendon sleeve avulsions predominantly occurred in middle-aged men with preexisting insertional disease, while engaged in athletic activity. Suture anchor fixation, combined with addressing concomitant insertional pathology, was a reliable and safe technique for the operative management of Achilles tendon sleeve avulsions. The majority of patients returned to their preinjury levels of work and recreational activity. Level IV, retrospective case series. © The Author(s) 2016.

  16. [EFFECT OF RECOMBINANT ADENOVIRUS-BONE MORPHOGENETIC PROTEIN 12 TRANSFECTION ON DIFFERENTIATION OF PERIPHERAL BLOOD MESENCHYMAL STEM CELLS INTO TENDON/LIGAMENT CELLS].

    PubMed

    Fu, Weili; Chen, Gang; Tang, Xin; Li, Qi; Ll, Jian

    2015-04-01

    To research the effect of recombinant adenovirus-bone morphogenetic protein 12 (Ad-BMP-12) transfection on the differentiation of peripheral blood mesenchymal stem cells (MSCs) into tendon/ligament cells. Peripheral blood MSCs were isolated from New Zealand rabbits (3-4 months old) and cultured in vitro until passage 3. The recombinant adenoviral vector system was prepared using AdEasy system, then transfected into MSCs at passage 3 (transfected group); untransfected MSCs served as control (untransfected group). The morphological characteristics and growth of transfected cells were observed under inverted phase contrast microscope. The transfection efficiency and green fluorescent protein (GFP) expression were detected by flow cytometry (FCM) and fluorescence microscopy. After cultured for 14 days in vitro, the expressions of tendon/ligament-specific markers were determined by immunohistochemistry and real-time fluorescent quantitative PCR. GFP expression could be observed in peripheral blood MSCs at 8 hours after transfection. At 24 hours after transfection, the cells had clear morphology and grew slowly under inverted phase contrast microscope and almost all expressed GFP at the same field under fluorescence microscopy. FCM analysis showed that the transfection efficiency of the transfected group was 99.57%, while it was 2.46% in the untransfected group. The immunohistochemistry showed that the expression of collagen type I gradually increased with culture time in vitro. Real-time fluorescent quantitative PCR results showed that the mRNA expressions of the tendon/ligament-specific genes (Tenomodulin, Tenascin-C, and Decorin) in the transfected group were significantly higher than those in untransfected group (0.061+/- 0.013 vs. 0.004 +/- 0.002, t = -7.700, P=0.031; 0.029 +/- 0.008 vs. 0.003 +/- 0.001, t = -5.741, P=0.020; 0.679 +/- 0.067 vs. 0.142 +/- 0.024, t = -12.998, P=0.000). Ad-BMP-12 can significantly promote differentiation of peripheral blood MSCs into tendon/ligament fibroblasts and enhance the expressions of tendon/ligament-specific phenotypic differentiation, which would provide the evidence for peripheral blood MSCs applied for tendon/ligament regeneration.

  17. Articulated Bone Block for Posterior Cruciate Ligament Reconstruction Using Bone-Patellar Tendon-Bone Autograft: Surgical Technique to Facilitate Graft Passage.

    PubMed

    Cugat, Ramón; Alentorn-Geli, Eduard; Cuscó, Xavier; Navarro, Jordi; Steinbacher, Gilbert; Álvarez-Díaz, Pedro; Seijas, Roberto; Barastegui, David; García-Balletbó, Montse

    2018-02-01

    Posterior cruciate ligament reconstruction using the transtibial technique provides successful clinical outcomes. However, a bone-patellar tendon-bone (BTB) autograft with the transtibial technique has not been used by some surgeons because of concerns with graft passage from the tibial to the femoral tunnels (sharp turn) that can damage graft fibers. In the present surgical technique, an arthroscopic, transtibial, single-bundle technique for posterior cruciate ligament reconstruction using the BTB autograft with an easy and effective technical tip to facilitate graft passage is presented. Once the BTB is harvested, the femoral bone block is divided into 2 equal-sized blocks providing an articulated structure while preserving the tendon component. This facilitates the passage of the BTB tendon once it is entered in the posterior tibia and the graft has to make a sharp turn to reach the femoral tunnel. This easy and effective technique tip may avoid graft damage during the sharp turn, while maintaining all the advantages of a BTB autograft (bone-to-bone healing, own tissue with fast incorporation, and strong fixation and stability).

  18. Extracellular vesicles of calcifying turkey leg tendon characterized by immunocytochemistry and high voltage electron microscopic tomography and 3-D graphic image reconstruction

    NASA Technical Reports Server (NTRS)

    Landis, W. J.; Hodgens, K. J.; McKee, M. D.; Nanci, A.; Song, M. J.; Kiyonaga, S.; Arena, J.; McEwen, B.

    1992-01-01

    To gain insight into the structure and possible function of extracellular vesicles in certain calcifying vertebrate tissues, normally mineralizing leg tendons from the domestic turkey, Meleagris gallopavo, have been studied in two separate investigations, one concerning the electron microscopic immunolocalization of the 66 kDa phosphoprotein, osteopontin, and the other detailing the organization and distribution of mineral crystals associated with the vesicles as determined by high voltage microscopic tomography and 3-D graphic image reconstruction. Immunolabeling shows that osteopontin is related to extracellular vesicles of the tendon in the sense that its initial presence appears coincident with the development of mineral associated with the vesicle loci. By high voltage electron microscopy and 3-D imaging techniques, mineral crystals are found to consist of small irregularly shaped particles somewhat randomly oriented throughout individual vesicles sites. Their appearance is different from that found for the mineral observed within calcifying tendon collagen, and their 3-D disposition is not regularly ordered. Possible spatial and temporal relationships of vesicles, osteopontin, mineral, and collagen are being examined further by these approaches.

  19. Melt electrowriting below the critical translation speed to fabricate crimped elastomer scaffolds with non-linear extension behaviour mimicking that of ligaments and tendons.

    PubMed

    Hochleitner, Gernot; Chen, Fei; Blum, Carina; Dalton, Paul D; Amsden, Brian; Groll, Jürgen

    2018-05-01

    Ligaments and tendons are comprised of aligned, crimped collagen fibrils that provide tissue-specific mechanical properties with non-linear extension behaviour, exhibiting low stress at initial strain (toe region behaviour). To approximate this behaviour, we report fibrous scaffolds with sinusoidal patterns by melt electrowriting (MEW) below the critical translation speed (CTS) by exploitation of the natural flow behaviour of the polymer melt. More specifically, we synthesised photopolymerizable poly(L-lactide-co-ε-caprolactone-co-acryloyl carbonate) (p(LLA-co-ε-CL-co-AC)) and poly(ε-caprolactone-co-acryloyl carbonate) (p(ε-CL-co-AC)) by ring-opening polymerization (ROP). Single fibre (fØ = 26.8 ± 1.9 µm) tensile testing revealed a customisable toe region with Young's Moduli ranging from E = 29 ± 17 MPa for the most crimped structures to E = 314 ± 157 MPa for straight fibres. This toe region extended to scaffolds containing multiple fibres, while the sinusoidal pattern could be influenced by printing speed. The synthesized polymers were cytocompatible and exhibited a tensile strength of σ = 26 ± 7 MPa after 10 4 cycles of preloading at 10% strain while retaining the distinct toe region commonly observed in native ligaments and tendon tissue. Damaged tendons and ligaments are serious and frequently occurring injuries worldwide. Recent therapies, including autologous grafts, still have severe disadvantages leading to a demand for synthetic alternatives. Materials envisioned to induce tendon and ligament regeneration should be degradable, cytocompatible and mimic the ultrastructural and mechanical properties of the native tissue. Specifically, we utilised photo-cross-linkable polymers for additive manufacturing (AM) with MEW. In this way, we were able to direct-write cytocompatible fibres of a few micrometres thickness into crimp-structured elastomer scaffolds that mimic the non-linear biomechanical behaviour of tendon and ligament tissue. Copyright © 2018 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  20. Extended healing validation of an artificial tendon to connect the quadriceps muscle to the Tibia: 180-day study.

    PubMed

    Melvin, Alan J; Litsky, Alan S; Mayerson, Joel L; Stringer, Keith; Juncosa-Melvin, Natalia

    2012-07-01

    Whenever a tendon or its bone insertion is disrupted or removed, existing surgical techniques provide a temporary connection or scaffolding to promote healing, but the interface of living to non-living materials soon breaks down under the stress of these applications, if it must bear the load more than acutely. Patients are thus disabled whose prostheses, defect size, or mere anatomy limit the availability or outcomes of such treatments. Our group developed the OrthoCoupler™ device to join skeletal muscle to prosthetic or natural structures without this interface breakdown. In this study, the goat knee extensor mechanism (quadriceps tendon, patella, and patellar tendon) was removed from the right hind limb in 16 goats. The device connected the quadriceps muscle to a stainless steel bone plate on the tibia. Mechanical testing and histology specimens were collected from each operated leg and contralateral unoperated control legs at 180 days. Maximum forces in the operated leg (vs. unoperated) were 1,400 ± 93 N (vs. 1,179 ± 61 N), linear stiffnesses were 33 ± 3 N/mm (vs. 37 ± 4 N/mm), and elongations at failure were 92.1 ± 5.3 mm (vs. 68.4 ± 3.8 mm; mean ± SEM). Higher maximum forces (p = 0.02) and elongations at failure (p=0.008) of legs with the device versus unoperated controls were significant; linear stiffnesses were not (p=0.3). We believe this technology will yield improved procedures for clinical challenges in orthopedic oncology, revision arthroplasty, tendon transfer, and tendon injury reconstruction. Copyright © 2011 Orthopaedic Research Society.

  1. Effectiveness of the Simultaneous Stretching of the Achilles Tendon and Plantar Fascia in Individuals With Plantar Fasciitis.

    PubMed

    Engkananuwat, Phoomchai; Kanlayanaphotporn, Rotsalai; Purepong, Nithima

    2018-01-01

    Since the plantar fascia and the Achilles tendon are anatomically connected, it is plausible that stretching of both structures simultaneously will result in a better outcome for plantar fasciitis. Fifty participants aged 40 to 60 years with a history of plantar fasciitis greater than 1 month were recruited. They were prospectively randomized into 2 groups. Group 1 was instructed to stretch the Achilles tendon while group 2 simultaneously stretched the Achilles tendon and plantar fascia. After 4 weeks of both stretching protocols, participants in group 2 demonstrated a significantly greater pressure pain threshold than participants in group 1 ( P = .040) with post hoc analysis. No significant differences between groups were demonstrated in other variables ( P > .05). Concerning within-group comparisons, both interventions resulted in significant reductions in pain at first step in the morning and average pain at the medial plantar calcaneal region over the past 24 hours, while there were increases in the pressure pain threshold, visual analog scale-foot and ankle score, and range of motion in ankle dorsiflexion ( P < .001). More participants in group 2 described their symptoms as being much improved to being completely improved than those in group 1. The simultaneous stretching of the Achilles tendon and plantar fascia for 4 weeks was a more effective intervention for plantar fasciitis. Patients who reported complete relief from symptoms at the end of the 4-week intervention in the simultaneous stretching group (n = 14; 56%) were double that of the stretching of the Achilles tendon-only group (n = 7; 28%). II, lesser quality RCT or prospective comparative study.

  2. Surgical anatomy of the lower trapezius tendon transfer.

    PubMed

    Omid, Reza; Cavallero, Matthew J; Granholm, Danielle; Villacis, Diego C; Yi, Anthony M

    2015-09-01

    The precise surgical anatomy of the lower trapezius tendon transfer has not been well described. A precise anatomic description of the different trapezius segments and the associated neurovascular structures is crucial for operative planning and execution. We aimed (1) to establish a reliable demarcation between the middle and lower trapezius, (2) to establish the precise relationship of the main neurovascular pedicle to the muscle belly, and (3) to evaluate the utility of the relationships established in (1) and (2) by using the results of this study to perform cadaveric lower trapezius tendon harvest. In phase 1, a single surgeon performed all measurements using 10 cadavers. In phase 2, 10 cadaveric shoulders were used to harvest the tendon by using the relationships established in phase 1. We found anatomically distinct insertion sites for the lower and middle trapezius. The lower trapezius inserted at the scapular spine dorsum and the middle trapezius inserted broadly along the superior surface of the scapular spine. The distance from tip of tendon insertion to the nearest nerve at the most superior portion of the lower trapezius was 58 mm (standard deviation ± 18). By use of these relationships, there were no cases of neurovascular injury during our cadaveric tendon harvests. The lower trapezius can be reliably and consistently identified without violating fibers of the middle trapezius. Muscle splitting can be performed safely without encountering the spinal accessory nerve (approximately 2 cm medial to the medial scapular border). Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  3. Multiscale mechanical effects of native collagen cross-linking in tendon.

    PubMed

    Eekhoff, Jeremy D; Fang, Fei; Lake, Spencer P

    2018-06-06

    The hierarchical structure of tendon allows for attenuation of mechanical strain down decreasing length scales. While reorganization of collagen fibers accounts for microscale strain attenuation, cross-linking between collagen molecules contributes to deformation mechanisms at the fibrillar and molecular scales. Divalent and trivalent enzymatic cross-links form during the development of collagen fibrils through the enzymatic activity of lysyl oxidase (LOX). By establishing connections between telopeptidyl and triple-helical domains of adjacent molecules within collagen fibrils, these cross-links stiffen the fibrils by resisting intermolecular sliding. Ultimately, greater enzymatic cross-linking leads to less compliant and stronger tendon as a result of stiffer fibrils. In contrast, nonenzymatic cross-links such as glucosepane and pentosidine are not produced during development but slowly accumulate through glycation of collagen. Therefore, these cross-links are only expected to be present in significant quantities in advanced age, where there has been sufficient time for glycation to occur, and in diabetes, where the presence of more free sugar in the extracellular matrix increases the rate of glycation. Unlike enzymatic cross-links, current evidence suggests that nonenzymatic cross-links are at least partially isolated to the surface of collagen fibers. As a result, glycation has been proposed to primarily impact tendon mechanics by altering molecular interactions at the fiber interface, thereby diminishing sliding between fibers. Thus, increased nonenzymatic cross-linking decreases microscale strain attenuation and the viscous response of tendon. In conclusion, enzymatic and nonenzymatic collagen cross-links have demonstrable and distinct effects on the mechanical properties of tendon across different length scales.

  4. [Reconstruction of big rotator cuff ruptures. A new technique of tendon refixation with the corkscrew suture anchor system].

    PubMed

    Kessler, M A; Lichtenberg, S; Habermeyer, P

    2003-10-01

    Tendon retraction and fatty degeneration is a major problem in repair of massive rotator cuff tears. Especially in the transosseous refixation technique, a tension-free refixation cannot be obtained in all cases. The purpose of this prospective study was to evaluate the postoperative results using a new tension-free reinsertion technique with a Corkscrew suture anchor system. Thirty patients (25 males, 5 females) with complete one and two tendon tears underwent open rotator cuff repair (rupture of one tendon: n=14, 47%). The torn tendons were mobilized and reinserted medially to reduce tension. Medialization was achieved by inserting tendon near the osteochondral border in a bony trough. The number of implanted suture anchors ranged from 2 to 6 (mean: 3.56). The mean age was 56 years (39-68 years) with a follow-up of 24 months (17-33 months). In one patient physical and sonographic examination showed a complete and in two patients a partial rerupture. A temporarily frozen shoulder occurred in two cases. No infection or rejection response was seen. In no case was revision surgery necessary. No displacement or loosening of the Corkscrew anchors was noticed. The constant score improved from 45 points preoperatively to 85 points at the time of follow-up (mean). The Corkscrew suture anchor system in combination with the new suture technique offers the possibility of a stable reinsertion even in reduced calcified bone structure. This facilitates good conditions for stable fibroblastic healing. Our midterm results show good osseous union combined with a low rerupture rate.

  5. The anatomical basis for disease localisation in seronegative spondyloarthropathy at entheses and related sites

    PubMed Central

    BENJAMIN, M.; McGONAGLE, D.

    2001-01-01

    The 2 major categories of idiopathic inflammatory arthritis are rheumatoid arthritis and the seronegative spondyloarthropathies. Whilst the synovium is the primary site of joint disease in the former, the primary site in the latter is less well defined. However, it has recently been proposed that enthesitis-associated changes in the spondyloarthropathies are primary and that all other joint manifestations are secondary. Nevertheless, some of the sites of disease localisation have not been adequately explained in terms of enthesitis. This article summarises current knowledge of the structure, function, blood supply, innervation, molecular composition and histopathology of the classic enthesis (i.e. the bony attachment of a tendon or ligament) and introduces the concept of ‘functional’ and articular ‘fibrocartilaginous’ entheses. The former are regions where tendons or ligaments wrap-around bony pulleys, but are not attached to them, and the latter are synovial joints that are lined by fibrocartilage rather than hyaline cartilage. We describe how these 3 types of entheses relate to other, and how all are prone to pathological changes in spondyloarthropathy. We propose that the inflammatory responses characteristic of spondyloarthropathies are triggered at these seemingly diverse sites, in genetically susceptible individuals, by a combination of anatomical factors which lead to higher levels of tissue microtrauma, and the deposition of microbes. PMID:11760883

  6. Decellularized Versus Fresh-Frozen Allografts in Anterior Cruciate Ligament Reconstruction: An In Vitro Study in a Rabbit Model.

    PubMed

    Dong, Shikui; Huangfu, Xiaoqiao; Xie, Guoming; Zhang, Yang; Shen, Peng; Li, Xiaoxi; Qi, Jin; Zhao, Jinzhong

    2015-08-01

    The common fresh-frozen allografts that are used for anterior cruciate ligament (ACL) reconstructions behave slower during the remodeling process and produce weaker tendon-bone integrations than do autografts. Decellularization of allogenic tendons results in a clean and porous collagen scaffold with low antigenicity and high compatibility, which may be more suitable for ACL reconstructions. Allograft decellularization will result in a tissue structure with suitable mechanical characteristics for ACL reconstruction, thereby promoting graft remodeling and enhancing tendon-bone healing. Controlled laboratory study. Decellularized allograft tissues were prepared with a pH-modified decellularization process and evaluated for their biocompatibility and biomechanical character in vitro. Eighty New Zealand White rabbits were divided into 2 groups, with 40 in each group, to receive ACL reconstruction with either fresh-frozen (common) allografts or decellularized allografts on both knees. At 2, 4, 8, and 12 weeks postoperatively, the rabbits were euthanized for biomechanical testing, micro-computed tomography analysis, and histologic analysis. The pH-modified decellularized allograft tissues kept excellent biocompatibility and biomechanical character during the in vitro study. Biomechanical testing indicated that the decellularized allograft had significantly higher ultimate load (P = .02) and stiffness (P = .01) levels than the common allograft at 12 weeks, and there was no significant difference between the 2 groups at any other time point. The micro-CT evaluation determined significantly higher bone mineral density (P < .01) in the decellularized allograft group than that in the common allograft group at 12 weeks, but no difference between the 2 groups was observed at any other time point. Regarding bone volume/total volume, there was no difference between the 2 groups at any time point. Fibroblast ingrowths, vascular formation, and connective tissue formation in the tendon-bone interface were better in the decellularized group within 8 weeks. New bone formation was more common in the decellularized allograft group. The collagen birefringence was restored more quickly in the decellularized allograft group than in the common allograft group at all time points. The use of pH-modified decellularized allografts compared with the common allografts resulted in better cellularity, vascularity, collagen matrix remolding, new bone formation around the graft, enhanced tendon-bone healing, and higher ultimate failure load and stiffness of the graft after ACL reconstruction in the rabbit model. The pH-modified decellularized allograft may be a better graft option than the common fresh-frozen allograft for knee ligament reconstructions. © 2015 The Author(s).

  7. The effect of seprafilm on adhesion formation and tendon healing after flexor tendon repair in chicken.

    PubMed

    Yilmaz, Erhan; Avci, Mustafa; Bulut, Mehmet; Kelestimur, Halidun; Karakurt, Lokman; Ozercan, Ibrahim

    2010-03-01

    Adhesion of the tendon, which can occur during healing of tendon repair, is negatively affected by the outcome of surgery. In this experimental study, we sought to prevent adhesion of the tendon, and determined the mechanical stiffness of repair tissue by wrapping sodium hyaluronate and carboxymethylcellulose (Seprafilm; Genzyme, Cambridge, Massachusetts) around the repaired tendon segments. The study group comprised 2 groups of 20 chickens. In group I, the right gastrocnemius tendons of the chickens were cut smoothly, and after tendon and sheath repair, the skin was sutured. In group II, the right gastrocnemius tendons of the chickens were cut, the tendons were repaired, and before skin closure, Seprafilm was wrapped around the repaired tendon segments. Plastic splints were used for holding the chickens' ankles in a neutral position, and they were allowed weight bearing for 8 weeks. In group II, anatomic space between the tendon-sheath and tendon was clear and the tendon-sheath complex was sliding easily around the repaired tendon segment, and this complex was more functional both biomechanically and histologically. Also, the Seprafilm-applied tendons (group II) were observed to be biomechanically more resistant to the tensile forces in group I. Seprafilm is an easily applied interpositional material that can be used safely to prevent adhesion during the tendon healing process. Copyright 2010, SLACK Incorporated.

  8. Minimally Invasive Posterior Hamstring Harvest

    PubMed Central

    Wilson, Trent J.; Lubowitz, James H.

    2013-01-01

    Autogenous hamstring harvesting for knee ligament reconstruction is a well-established standard. Minimally invasive posterior hamstring harvest is a simple, efficient, reproducible technique for harvest of the semitendinosus or gracilis tendon or both medial hamstring tendons. A 2- to 3-cm longitudinal incision from the popliteal crease proximally, in line with the semitendinosus tendon, is sufficient. The deep fascia is bluntly penetrated, and the tendon or tendons are identified. Adhesions are dissected. Then, an open tendon stripper is used to release the tendon or tendons proximally; a closed, sharp tendon stripper is used to release the tendon or tendons from the pes. Layered, absorbable skin closure is performed, and the skin is covered with a skin sealant, bolster dressing, and plastic adhesive bandage for 2 weeks. PMID:24266003

  9. What We Should Know Before Using Tissue Engineering Techniques to Repair Injured Tendons: A Developmental Biology Perspective

    PubMed Central

    Liu, Chia-Feng; Aschbacher-Smith, Lindsey; Barthelery, Nicolas J.; Dyment, Nathaniel; Butler, David

    2011-01-01

    Tendons connect muscles to bones, and serve as the transmitters of force that allow all the movements of the body. Tenocytes are the basic cellular units of tendons, and produce the collagens that form the hierarchical fiber system of the tendon. Tendon injuries are common, and difficult to repair, particularly in the case of the insertion of tendon into bone. Successful attempts at cell-based repair therapies will require an understanding of the normal development of tendon tissues, including their differentiated regions such as the fibrous mid-section and fibrocartilaginous insertion site. Many genes are known to be involved in the formation of tendon. However, their functional roles in tendon development have not been fully characterized. Tissue engineers have attempted to generate functional tendon tissue in vitro. However, a lack of knowledge of normal tendon development has hampered these efforts. Here we review studies focusing on the developmental mechanisms of tendon development, and discuss the potential applications of a molecular understanding of tendon development to the treatment of tendon injuries. PMID:21314435

  10. Effect of single intralesional treatment of surgically induced equine superficial digital flexor tendon core lesions with adipose-derived mesenchymal stromal cells: a controlled experimental trial.

    PubMed

    Geburek, Florian; Roggel, Florian; van Schie, Hans T M; Beineke, Andreas; Estrada, Roberto; Weber, Kathrin; Hellige, Maren; Rohn, Karl; Jagodzinski, Michael; Welke, Bastian; Hurschler, Christof; Conrad, Sabine; Skutella, Thomas; van de Lest, Chris; van Weeren, René; Stadler, Peter M

    2017-06-05

    Adipose tissue is a promising source of mesenchymal stromal cells (MSCs) for the treatment of tendon disease. The goal of this study was to assess the effect of a single intralesional implantation of adipose tissue-derived mesenchymal stromal cells (AT-MSCs) on artificial lesions in equine superficial digital flexor tendons (SDFTs). During this randomized, controlled, blinded experimental study, either autologous cultured AT-MSCs suspended in autologous inactivated serum (AT-MSC-serum) or autologous inactivated serum (serum) were injected intralesionally 2 weeks after surgical creation of centrally located SDFT lesions in both forelimbs of nine horses. Healing was assessed clinically and with ultrasound (standard B-mode and ultrasound tissue characterization) at regular intervals over 24 weeks. After euthanasia of the horses the SDFTs were examined histologically, biochemically and by means of biomechanical testing. AT-MSC implantation did not substantially influence clinical and ultrasonographic parameters. Histology, biochemical and biomechanical characteristics of the repair tissue did not differ significantly between treatment modalities after 24 weeks. Compared with macroscopically normal tendon tissue, the content of the mature collagen crosslink hydroxylysylpyridinoline did not differ after AT-MSC-serum treatment (p = 0.074) while it was significantly lower (p = 0.027) in lesions treated with serum alone. Stress at failure (p = 0.048) and the modulus of elasticity (p = 0.001) were significantly lower after AT-MSC-serum treatment than in normal tendon tissue. The effect of a single intralesional injection of cultured AT-MSCs suspended in autologous inactivated serum was not superior to treatment of surgically created SDFT lesions with autologous inactivated serum alone in a surgical model of tendinopathy over an observation period of 22 weeks. AT-MSC treatment might have a positive influence on collagen crosslinking of remodelling scar tissue. Controlled long-term studies including naturally occurring tendinopathies are necessary to verify the effects of AT-MSCs on tendon disease.

  11. Transcription factor EGR1 directs tendon differentiation and promotes tendon repair

    PubMed Central

    Guerquin, Marie-Justine; Charvet, Benjamin; Nourissat, Geoffroy; Havis, Emmanuelle; Ronsin, Olivier; Bonnin, Marie-Ange; Ruggiu, Mathilde; Olivera-Martinez, Isabel; Robert, Nicolas; Lu, Yinhui; Kadler, Karl E.; Baumberger, Tristan; Doursounian, Levon; Berenbaum, Francis; Duprez, Delphine

    2013-01-01

    Tendon formation and repair rely on specific combinations of transcription factors, growth factors, and mechanical parameters that regulate the production and spatial organization of type I collagen. Here, we investigated the function of the zinc finger transcription factor EGR1 in tendon formation, healing, and repair using rodent animal models and mesenchymal stem cells (MSCs). Adult tendons of Egr1–/– mice displayed a deficiency in the expression of tendon genes, including Scx, Col1a1, and Col1a2, and were mechanically weaker compared with their WT littermates. EGR1 was recruited to the Col1a1 and Col2a1 promoters in postnatal mouse tendons in vivo. Egr1 was required for the normal gene response following tendon injury in a mouse model of Achilles tendon healing. Forced Egr1 expression programmed MSCs toward the tendon lineage and promoted the formation of in vitro–engineered tendons from MSCs. The application of EGR1-producing MSCs increased the formation of tendon-like tissues in a rat model of Achilles tendon injury. We provide evidence that the ability of EGR1 to promote tendon differentiation is partially mediated by TGF-β2. This study demonstrates EGR1 involvement in adult tendon formation, healing, and repair and identifies Egr1 as a putative target in tendon repair strategies. PMID:23863709

  12. Surface Modification Counteracts Adverse Effects Associated with Immobilization after Flexor Tendon Repair

    PubMed Central

    Zhao, Chunfeng; Sun, Yu-Long; Jay, Gregory D.; Moran, Steven L.; An, Kai-Nan; Amadio, Peter C.

    2012-01-01

    SUMMARY Although post-rehabilitation is routinely performed following flexor tendon repair, in some clinical scenarios post-rehabilitation must be delayed. We investigated modification of the tendon surface using carbodiimide derivatized hyaluronic acid and lubricin (cd-HA-Lub) to maintain gliding function following flexor tendon repair with postoperative immobilization in a in vivo canine model. Flexor digitorum profundus tendons from the 2nd and 5th digits of one forepaw of six dogs were transected and repaired. One tendon in each paw was treated with cd-HA-Lub; the other repaired tendon was not treated. Following tendon repair, a forearm cast was applied to fully immobilize the operated forelimb for 10 days, after which the animals were euthanized. Digit normalized work of flexion (nWOF) and tendon gliding resistance were assessed. The nWOF of the FDP tendons treated with cd-HA-Lub was significantly lower than the nWOF of the untreated tendons (p < 0.01). The gliding resistance of cd-HA-Lub treated tendons was also significantly lower than that of the untreated tendons (p < 0.05). Surface treatment with cd-HA-Lub following flexor tendon repair provides an opportunity to improve outcomes for patients in whom the post-operative therapy must be delayed after flexor tendon repair. PMID:22714687

  13. Specialization of tendon mechanical properties results from interfascicular differences

    PubMed Central

    Thorpe, Chavaunne T.; Udeze, Chineye P.; Birch, Helen L.; Clegg, Peter D.; Screen, Hazel R. C.

    2012-01-01

    Tendons transfer force from muscle to bone. Specific tendons, including the equine superficial digital flexor tendon (SDFT), also store and return energy. For efficient function, energy-storing tendons need to be more extensible than positional tendons such as the common digital extensor tendon (CDET), and when tested in vitro have a lower modulus and failure stress, but a higher failure strain. It is not known how differences in matrix organization contribute to distinct mechanical properties in functionally different tendons. We investigated the properties of whole tendons, tendon fascicles and the fascicular interface in the high-strain energy-storing SDFT and low-strain positional CDET. Fascicles failed at lower stresses and strains than tendons. The SDFT was more extensible than the CDET, but SDFT fascicles failed at lower strains than CDET fascicles, resulting in large differences between tendon and fascicle failure strain in the SDFT. At physiological loads, the stiffness at the fascicular interface was lower in the SDFT samples, enabling a greater fascicle sliding that could account for differences in tendon and fascicle failure strain. Sliding between fascicles prior to fascicle extension in the SDFT may allow the large extensions required in energy-storing tendons while protecting fascicles from damage. PMID:22764132

  14. Specialization of tendon mechanical properties results from interfascicular differences.

    PubMed

    Thorpe, Chavaunne T; Udeze, Chineye P; Birch, Helen L; Clegg, Peter D; Screen, Hazel R C

    2012-11-07

    Tendons transfer force from muscle to bone. Specific tendons, including the equine superficial digital flexor tendon (SDFT), also store and return energy. For efficient function, energy-storing tendons need to be more extensible than positional tendons such as the common digital extensor tendon (CDET), and when tested in vitro have a lower modulus and failure stress, but a higher failure strain. It is not known how differences in matrix organization contribute to distinct mechanical properties in functionally different tendons. We investigated the properties of whole tendons, tendon fascicles and the fascicular interface in the high-strain energy-storing SDFT and low-strain positional CDET. Fascicles failed at lower stresses and strains than tendons. The SDFT was more extensible than the CDET, but SDFT fascicles failed at lower strains than CDET fascicles, resulting in large differences between tendon and fascicle failure strain in the SDFT. At physiological loads, the stiffness at the fascicular interface was lower in the SDFT samples, enabling a greater fascicle sliding that could account for differences in tendon and fascicle failure strain. Sliding between fascicles prior to fascicle extension in the SDFT may allow the large extensions required in energy-storing tendons while protecting fascicles from damage.

  15. Gene expression profiles of changes underlying different-sized human rotator cuff tendon tears.

    PubMed

    Chaudhury, Salma; Xia, Zhidao; Thakkar, Dipti; Hakimi, Osnat; Carr, Andrew J

    2016-10-01

    Progressive cellular and extracellular matrix (ECM) changes related to age and disease severity have been demonstrated in rotator cuff tendon tears. Larger rotator cuff tears demonstrate structural abnormalities that potentially adversely influence healing potential. This study aimed to gain greater insight into the relationship of pathologic changes to tear size by analyzing gene expression profiles from normal rotator cuff tendons, small rotator cuff tears, and large rotator cuff tears. We analyzed gene expression profiles of 28 human rotator cuff tendons using microarrays representing the entire genome; 11 large and 5 small torn rotator cuff tendon specimens were obtained intraoperatively from tear edges, which we compared with 12 age-matched normal controls. We performed real-time polymerase chain reaction and immunohistochemistry for validation. Torn rotator cuff tendons demonstrated upregulation of a number of key genes, such as matrix metalloproteinase 3, 10, 12, 13, 15, 21, and 25; a disintegrin and metalloproteinase (ADAM) 12, 15, and 22; and aggrecan. Amyloid was downregulated in all tears. Small tears displayed upregulation of bone morphogenetic protein 5. Chemokines and cytokines that may play a role in chemotaxis were altered; interleukins 3, 10, 13, and 15 were upregulated in tears, whereas interleukins 1, 8, 11, 18, and 27 were downregulated. The gene expression profiles of normal controls and small and large rotator cuff tear groups differ significantly. Extracellular matrix remodeling genes were found to contribute to rotator cuff tear pathogenesis. Rotator cuff tears displayed upregulation of a number of matrix metalloproteinase (3, 10, 12, 13, 15, 21, and 25), a disintegrin and metalloproteinase (ADAM 12, 15, and 22) genes, and downregulation of some interleukins (1, 8, and 27), which play important roles in chemotaxis. These gene products may potentially have a role as biomarkers of failure of healing or therapeutic targets to improve tendon healing. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  16. Biologics for tendon repair☆

    PubMed Central

    Docheva, Denitsa; Müller, Sebastian A.; Majewski, Martin; Evans, Christopher H.

    2015-01-01

    Tendon injuries are common and present a clinical challenge to orthopedic surgery mainly because these injuries often respond poorly to treatment and require prolonged rehabilitation. Therapeutic options used to repair ruptured tendons have consisted of suture, autografts, allografts, and synthetic prostheses. To date, none of these alternatives has provided a successful long-term solution, and often the restored tendons do not recover their complete strength and functionality. Unfortunately, our understanding of tendon biology lags far behind that of other musculoskeletal tissues, thus impeding the development of new treatment options for tendon conditions. Hence, in this review, after introducing the clinical significance of tendon diseases and the present understanding of tendon biology, we describe and critically assess the current strategies for enhancing tendon repair by biological means. These consist mainly of applying growth factors, stem cells, natural biomaterials and genes, alone or in combination, to the site of tendon damage. A deeper understanding of how tendon tissue and cells operate, combined with practical applications of modern molecular and cellular tools could provide the long awaited breakthrough in designing effective tendon-specific therapeutics and overall improvement of tendon disease management. PMID:25446135

  17. Investigating tendon mineralisation in the avian hindlimb: a model for tendon ageing, injury and disease

    PubMed Central

    Agabalyan, Natacha A; Evans, Darrell J R; Stanley, Rachael L

    2013-01-01

    Mineralisation of the tendon tissue has been described in various models of injury, ageing and disease. Often resulting in painful and debilitating conditions, the processes underlying this mechanism are poorly understood. To elucidate the progression from healthy tendon to mineralised tendon, an appropriate model is required. In this study, we describe the spontaneous and non-pathological ossification and calcification of tendons of the hindlimb of the domestic chicken (Gallus gallus domesticus). The appearance of the ossified avian tendon has been described previously, although there have been no studies investigating the developmental processes and underlying mechanisms leading to the ossified avian tendon. The tissue and cells from three tendons – the ossifying extensor and flexor digitorum longus tendons and the non-ossifying Achilles tendon – were analysed for markers of ageing and mineralisation using histology, immunohistochemistry, cytochemistry and molecular analysis. Histologically, the adult tissue showed a loss of healthy tendon crimp morphology as well as markers of calcium deposits and mineralisation. The tissue showed a lowered expression of collagens inherent to the tendon extracellular matrix and presented proteins expressed by bone. The cells from the ossified tendons showed a chondrogenic and osteogenic phenotype as well as tenogenic phenotype and expressed the same markers of ossification and calcification as the tissue. A molecular analysis of the gene expression of the cells confirmed these results. Tendon ossification within the ossified avian tendon seems to be the result of an endochondral process driven by its cells, although the roles of the different cell populations have yet to be elucidated. Understanding the role of the tenocyte within this tissue and the process behind tendon ossification may help us prevent or treat ossification that occurs in injured, ageing or diseased tendon. PMID:23826786

  18. Effects of celecoxib on proliferation and tenocytic differentiation of tendon-derived stem cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Kairui; Zhang, Sheng; Li, Qianqian

    Highlights: • Celecoxib has no effects on TDSCs cell proliferation in various concentrations. • Celecoxib reduced mRNAs levels of tendon associated transcription factor. • Celecoxib reduced mRNAs levels of main tendon associated collagen. • Celecoxib reduced mRNAs levels of tendon associated molecules. - Abstract: NSAIDs are often ingested to reduce the pain and improve regeneration of tendon after tendon injury. Although the effects of NSAIDs in tendon healing have been reported, the data and conclusions are not consistent. Recently, tendon-derived stem cells (TDSCs) have been isolated from tendon tissues and has been suggested involved in tendon repair. Our study aimsmore » to determine the effects of COX-2 inhibitor (celecoxib) on the proliferation and tenocytic differentiation of TDSCs. TDSCs were isolated from mice Achilles tendon and exposed to celecoxib. Cell proliferation rate was investigated at various concentrations (0.1, 1, 10 and 100 μg/ml) of celecoxib by using hemocytometer. The mRNA expression of tendon associated transcription factors, tendon associated collagens and tendon associated molecules were determined by reverse transcription-polymerase chain reaction. The protein expression of Collagen I, Collagen III, Scleraxis and Tenomodulin were determined by Western blotting. The results showed that celecoxib has no effects on TDSCs cell proliferation in various concentrations (p > 0.05). The levels of most tendon associated transcription factors, tendon associated collagens and tendon associated molecules genes expression were significantly decreased in celecoxib (10 μg/ml) treated group (p < 0.05). Collagen I, Collagen III, Scleraxis and Tenomodulin protein expression were also significantly decreased in celecoxib (10 μg/ml) treated group (p < 0.05). In conclusion, celecoxib inhibits tenocytic differentiation of tendon-derived stem cells but has no effects on cell proliferation.« less

  19. Fos Promotes Early Stage Teno-Lineage Differentiation of Tendon Stem/Progenitor Cells in Tendon.

    PubMed

    Chen, Jialin; Zhang, Erchen; Zhang, Wei; Liu, Zeyu; Lu, Ping; Zhu, Ting; Yin, Zi; Backman, Ludvig J; Liu, Huanhuan; Chen, Xiao; Ouyang, Hongwei

    2017-11-01

    Stem cells have been widely used in tendon tissue engineering. The lack of refined and controlled differentiation strategy hampers the tendon repair and regeneration. This study aimed to find new effective differentiation factors for stepwise tenogenic differentiation. By microarray screening, the transcript factor Fos was found to be expressed in significantly higher amounts in postnatal Achilles tendon tissue derived from 1 day as compared with 7-days-old rats. It was further confirmed that expression of Fos decreased with time in postnatal rat Achilles tendon, which was accompanied with the decreased expression of multiply tendon markers. The expression of Fos also declined during regular in vitro cell culture, which corresponded to the loss of tendon phenotype. In a cell-sheet and a three-dimensional cell culture model, the expression of Fos was upregulated as compared with in regular cell culture, together with the recovery of tendon phenotype. In addition, significant higher expression of tendon markers was found in Fos-overexpressed tendon stem/progenitor cells (TSPCs), and Fos knock-down gave opposite results. In situ rat tendon repair experiments found more normal tendon-like tissue formed and higher tendon markers expression at 4 weeks postimplantation of Fos-overexpressed TSPCs derived nonscaffold engineering tendon (cell-sheet), as compared with the control group. This study identifies Fos as a new marker and functional driver in the early stage teno-lineage differentiation of tendon, which paves the way for effective stepwise tendon differentiation and future tendon regeneration. Stem Cells Translational Medicine 2017;6:2009-2019. © 2017 The Authors Stem Cells Translational Medicine published by Wiley Periodicals, Inc. on behalf of AlphaMed Press.

  20. Hamstring tendon versus patellar tendon anterior cruciate ligament reconstruction using biodegradable interference fit fixation: a prospective matched-group analysis.

    PubMed

    Wagner, Michael; Kääb, Max J; Schallock, Jessica; Haas, Norbert P; Weiler, Andreas

    2005-09-01

    There are still controversies about graft selection for primary anterior cruciate ligament reconstruction, especially with respect to knee stability and functional outcome. Biodegradable interference screw fixation of hamstring tendon grafts provides clinical results similar to those achieved with identical fixation of bone-patellar tendon-bone grafts. Cohort study; Level of evidence, 2. In 1996 and 1997, primary isolated anterior cruciate ligament reconstruction using a bone-patellar tendon-bone autograft was performed in 72 patients. Since 1998, hamstring tendons were used as routine grafts. Matched patients with a hamstring tendon graft were selected from a database (n = 284). All patients were followed prospectively for a minimum of 2 years with KT-1000 arthrometer testing, International Knee Documentation Committee score, and Lysholm score. In the bone-patellar tendon-bone group, 9 patients were excluded because of bilateral rupture of the anterior cruciate ligament, 3 patients (4.2%) had a graft rupture, and 4 patients were lost to follow-up (follow-up rate, 92.1%), leaving 56 patients for a matched-group analysis. In the hamstring tendon database, the graft rupture rate was 5.6% (P = .698). The Lysholm score was 89.7 in the patellar tendon group and 94 in the hamstring tendon group (P = .003). The KT-1000 arthrometer side-to-side difference was 2.6 mm for the patellar tendon group and 2.1 mm for the hamstring tendon group (P = .041). There were significantly less positive pivot-shift test results in the hamstring tendon group (P = .005), and hamstring tendon patients showed lower thigh atrophy (P = .024) and patellofemoral crepitus (P = .003). Overall International Knee Documentation Committee scores were better (P = .001) in the hamstring tendon group (hamstring tendon: 34 x A, 21 x B, 0 x C, 0 x D; bone-patellar tendon-bone: 17 x A, 32 x B, 6 x C, 0 x D). In this comparison of anterior cruciate ligament reconstruction with bone-patellar tendon-bone and anatomical hamstring tendon grafts, the hamstring tendon graft was superior in knee stability and function. These findings are partially contrary to previous studies and might be attributable to the use of an anatomical joint line fixation for hamstring tendon grafts. Thus, hamstring tendons are the authors' primary graft choice for anterior cruciate ligament reconstruction, even in high-level athletes.

  1. Angiopoietin‐like 4 promotes angiogenesis in the tendon and is increased in cyclically loaded tendon fibroblasts

    PubMed Central

    Mousavizadeh, Rouhollah; Scott, Alex; Lu, Alex; Ardekani, Gholamreza S; Behzad, Hayedeh; Lundgreen, Kirsten; Ghaffari, Mazyar; McCormack, Robert G

    2016-01-01

    Key points Angiopoietin‐like 4 (ANGPTL4) modulates tendon neovascularization.Cyclic loading stimulates the activity of transforming growth factor‐β and hypoxia‐inducible factor 1α and thereby increases the expression and release of ANGPTL4 from human tendon cells.Targeting ANGPTL4 and its regulatory pathways is a potential avenue for regulating tendon vascularization to improve tendon healing or adaptation. Abstract The mechanisms that regulate angiogenic activity in injured or mechanically loaded tendons are poorly understood. The present study examined the potential role of angiopoietin‐like 4 (ANGPTL4) in the angiogenic response of tendons subjected to repetitive mechanical loading or injury. Cyclic stretching of human tendon fibroblasts stimulated the expression and release of ANGPTL4 protein via transforming growth factor‐β (TGF‐β) and hypoxia‐inducible factor 1α (HIF‐1α) signalling, and the released ANGPTL4 was pro‐angiogenic. Angiogenic activity was increased following ANGPTL4 injection into mouse patellar tendons, whereas the patellar tendons of ANGPTL4 knockout mice displayed reduced angiogenesis following injury. In human rotator cuff tendons, the expression of ANGPTL4 was correlated with the density of tendon endothelial cells. To our knowledge, this is the first study characterizing a role of ANGPTL4 in the tendon. ANGPTL4 may assist in the regulation of vascularity in the injured or mechanically loaded tendon. TGF‐β and HIF‐1α comprise two signalling pathways that modulate the expression of ANGPTL4 by mechanically stimulated tendon fibroblasts and, in the future, these could be manipulated to influence tendon healing or adaptation. PMID:26670924

  2. Successful conservative treatment outcomes and clinical characteristics of congenital hypoplasia of the extensor tendon central slip.

    PubMed

    Hidaka, N; Uemura, T; Nakamura, H

    2017-03-01

    Congenital hypoplasia of the extensor tendon central slip is a rare entity. This article describes the clinical characteristics in a series of 22 fingers in 16 patients (mean age: 10 months), and the outcomes of conservative treatment. Nine of 22 fingers were classified as slender or hypoplastic. Treatment with bracing was successful in 21 digits, resulting in full active extension of the proximal interphalangeal joint at a mean of 8.5 months after treatment. Bracing was unsuccessful in one digit, in which operative treatment resulted in a successful outcome. Some residual deformity was observed in ten fingers after a mean follow-up period of 2 years and 1 month. Congenital hypoplasia of the central slip can be treated successfully by the conservative hand bracing when worn with full compliance. Treatment time is extended by the infrequent application of the hand brace or in the case of hypoplastic slender fingers. IV.

  3. The effect of sterilization on mechanical properties of soft tissue allografts.

    PubMed

    Conrad, Bryan P; Rappé, Matthew; Horodyski, MaryBeth; Farmer, Kevin W; Indelicato, Peter A

    2013-09-01

    One major concern regarding soft tissue allograft use in surgical procedures is the risk of disease transmission. Current techniques of tissue sterilization, such as irradiation have been shown to adversely affect the mechanical properties of soft tissues. Grafts processed using Biocleanse processing (a proprietary technique developed by Regeneration Technologies to sterilize human tissues) will have better biomechanical characteristics than tissues that have been irradiated. Fifteen pairs of cadaveric Achilles tendon allografts were obtained and separated into three groups of 10 each. Three treatment groups were: Biocleanse, Irradiated, and Control (untreated). Each specimen was tested to determine the biomechanical properties of the tissue. Specimens were cyclically preloaded and then loaded to failure in tension. During testing, load, displacement, and optical strain data were captured. Following testing, the cross sectional area of the tendons was determined. Tendons in the control group were found to have a higher extrinsic stiffness (slope of the load-deformation curve, p = .005), have a higher ultimate stress (force/cross sectional area, p = .006) and higher ultimate failure load (p = .003) than irradiated grafts. Biocleanse grafts were also found to be stiffer than irradiated grafts (p = .014) yet were not found to be statistically different from either irradiated or non-irradiated grafts in terms of load to failure. Biocleanse processing seems to be a viable alternative to irradiation for Achilles tendon allografts sterilization in terms of their biomechanical properties.

  4. Relationship between severity of shoulder subluxation and soft-tissue injury in hemiplegic stroke patients.

    PubMed

    Huang, Shih-Wei; Liu, Sen-Yung; Tang, Hao-Wei; Wei, Ta-Sen; Wang, Wei-Te; Yang, Chao-Pin

    2012-09-01

    The aims of this study were: (i) to determine whether the severity of post-hemiplegic shoulder subluxation in stroke patients correlates with soft-tissue injury; and (ii) to determine the shoulder subluxation measurement cut-off points that are indications for further ultrasound examination for soft-tissue injuries in these patients. Cross-sectional study. A total of 39 stroke patients with shoulder subluxation. Shoulder subluxation was evaluated by physical examination, radiography and ultrasound. Soft-tissue injuries were assessed by ultrasound. Subluxation parameters were entered into stepwise logistic regression analyses to predict biceps and supraspinatus tendonitis. With the assumption that shoulder subluxation can be a predisposing factor for tendonitis, receiver operating characteristic curves for shoulder subluxation parameters of the affected side were used to determine cut-off points for optimal sensitivity and specificity of biceps and supraspinatus tendonitis. Shoulder subluxation lateral distance, measured by physical examination, is a predictor for supraspinatus tendonitis (odds ratio = 34.9, p = 0.036). Further ultrasound investigation for soft-tissue injury is indicated when subluxation lateral distance, measured by physical examination is ≥ 2.25 cm or, measured by radiographic examination, ≥ 3.18 cm for lateral distance, ≥ 3.08 cm for vertical distance, or ≥ 2.65 cm for horizontal distance. When post-hemiplegic shoulder subluxation measurements exceed the above-mentioned cut-off points in physical or radiographic examinations, further ultrasound evaluation for soft-tissue injury is recommended.

  5. Tendon injuries

    PubMed Central

    Wu, Fan; Nerlich, Michael; Docheva, Denitsa

    2017-01-01

    Tendons connect muscles to bones, ensuring joint movement. With advanced age, tendons become more prone to degeneration followed by injuries. Tendon repair often requires lengthy periods of rehabilitation, especially in elderly patients. Existing medical and surgical treatments often fail to regain full tendon function. The development of novel treatment methods has been hampered due to limited understanding of basic tendon biology. Recently, it was discovered that tendons, similar to other mesenchymal tissues, contain tendon stem/progenitor cells (TSPCs) which possess the common stem cell properties. The current strategies for enhancing tendon repair consist mainly of applying stem cells, growth factors, natural and artificial biomaterials alone or in combination. In this review, we summarise the basic biology of tendon tissues and provide an update on the latest repair proposals for tendon tears. Cite this article: EFORT Open Rev 2017;2:332-342. DOI: 10.1302/2058-5241.2.160075 PMID:28828182

  6. Tendon injuries of the hand

    PubMed Central

    Schöffl, Volker; Heid, Andreas; Küpper, Thomas

    2012-01-01

    Tendon injuries are the second most common injuries of the hand and therefore an important topic in trauma and orthopedic patients. Most injuries are open injuries to the flexor or extensor tendons, but less frequent injuries, e.g., damage to the functional system tendon sheath and pulley or dull avulsions, also need to be considered. After clinical examination, ultrasound and magnetic resonance imaging have proved to be important diagnostic tools. Tendon injuries mostly require surgical repair, dull avulsions of the distal phalanges extensor tendon can receive conservative therapy. Injuries of the flexor tendon sheath or single pulley injuries are treated conservatively and multiple pulley injuries receive surgical repair. In the postoperative course of flexor tendon injuries, the principle of early passive movement is important to trigger an “intrinsic” tendon healing to guarantee a good outcome. Many substances were evaluated to see if they improved tendon healing; however, little evidence was found. Nevertheless, hyaluronic acid may improve intrinsic tendon healing. PMID:22720265

  7. Evolution of the Achilles tendon: The athlete's Achilles heel?

    PubMed

    Malvankar, S; Khan, W S

    2011-12-01

    The Achilles tendon is believed to have first developed two million years ago enabling humans to run twice as fast. However if the Achilles tendon is so important in terms of evolution, then why is this tendon so prone to injury - especially for those more active like athletes. The Achilles tendon had an integral role in evolving apes from a herbivorous diet to early humans who started hunting for food over longer distances, resulting in bipedal locomotion. Evolutionary advantages of the Achilles tendon includes it being the strongest tendon in the body, having an energy-saving mechanism for fast locomotion, allows humans to jump and run, and additionally is a spring and shock absorber during gait. Considering these benefits it is therefore not surprising that studies have shown athletes have thicker Achilles tendons than subjects who are less active. However, contradictory to these findings that show the importance of the Achilles tendon for athletes, it is well known that obtaining an Achilles tendon injury for an athlete can be career-altering. A disadvantage of the Achilles tendon is that the aetiology of its pathology is complicated. Achilles tendon ruptures are believed to be caused by overloading the tensed tendon, like during sports. However studies have also shown athlete Achilles tendon ruptures to have degenerative changes in the tendon. Other flaws of the Achilles tendon are its non-uniform vascularity and incomplete repair system which may suggest the Achilles tendon is on the edge of evolution. Research has shown that there is a genetic influence on the predisposition a person has towards Achilles tendon injuries. So if this tendon is here to stay in our anatomy, and it probably is due to the slow rate of evolution in humans, research in genetic modification could be used to decrease athletes' predisposition to Achilles tendinopathy. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. Association between non-cholesterol sterol concentrations and Achilles tendon thickness in patients with genetic familial hypercholesterolemia.

    PubMed

    Baila-Rueda, Lucía; Lamiquiz-Moneo, Itziar; Jarauta, Estíbaliz; Mateo-Gallego, Rocío; Perez-Calahorra, Sofía; Marco-Benedí, Victoria; Bea, Ana M; Cenarro, Ana; Civeira, Fernando

    2018-01-15

    Familial hypercholesterolemia (FH) is a genetic disorder that result in abnormally high low-density lipoprotein cholesterol levels, markedly increased risk of coronary heart disease (CHD) and tendon xanthomas (TX). However, the clinical expression is highly variable. TX are present in other metabolic diseases that associate increased sterol concentration. If non-cholesterol sterols are involved in the development of TX in FH has not been analyzed. Clinical and biochemical characteristics, non-cholesterol sterols concentrations and Aquilles tendon thickness were determined in subjects with genetic FH with (n = 63) and without (n = 40) TX. Student-t test o Mann-Whitney test were used accordingly. Categorical variables were compared using a Chi square test. ANOVA and Kruskal-Wallis tests were performed to multiple independent variables comparison. Post hoc adjusted comparisons were performed with Bonferroni correction when applicable. Correlations of parameters in selected groups were calculated applying the non-parametric Spearman correlation procedure. To identify variables associated with Achilles tendon thickness changes, multiple linear regression were applied. Patients with TX presented higher concentrations of non-cholesterol sterols in plasma than patients without xanthomas (P = 0.006 and 0.034, respectively). Furthermore, there was a significant association between 5α-cholestanol, β-sitosterol, desmosterol, 24S-hydroxycholesterol and 27-hydroxycholesterol concentrations and Achilles tendon thickness (p = 0.002, 0.012, 0.020, 0.045 and 0.040, respectively). Our results indicate that non-cholesterol sterol concentrations are associated with the presence of TX. Since cholesterol and non-cholesterol sterols are present in the same lipoproteins, further studies would be needed to elucidate their potential role in the development of TX.

  9. Second Harmonic Generation Confocal Microscopy of Collagen Type I from Rat Tendon Cryosections

    PubMed Central

    Theodossiou, Theodossis A.; Thrasivoulou, Christopher; Ekwobi, Chidi; Becker, David L.

    2006-01-01

    We performed second harmonic generation (SHG) imaging of collagen in rat-tendon cryosections, using femtosecond laser scanning confocal microscopy, both in backscattering and transmission geometries. SHG transmission images of collagen fibers were spatially resolved due to a coherent, directional SHG component. This effect was enhanced with the use of an index-matching fluid (ni = 1.52). The average SHG intensity oscillated with wavelength in the backscattered geometry (isotropic SHG component), whereas the spectral profile was consistent with quasi-phase-matching conditions in transmission geometry (forward propagating, coherent SHG component) around 440 nm (λp = 880 nm). Collagen type I from bovine Achilles tendon was imaged for SHG in the backscattered geometry and its first-order effective nonlinear coefficient was determined (\\documentclass[10pt]{article} \\usepackage{amsmath} \\usepackage{wasysym} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{amsbsy} \\usepackage{mathrsfs} \\pagestyle{empty} \\oddsidemargin -1.0in \\begin{document} \\begin{equation*}{\\vert}d_{{\\mathrm{eff}}}{\\vert}\\approx 0.085({\\pm}0.025){\\times}10^{-12}{\\mathrm{mV}}^{-1}\\end{equation*}\\end{document}) by comparison to samples of inorganic materials with known effective nonlinear coefficients (LiNbO3 and LiIO3). The SHG spectral response of collagen type I from bovine Achilles tendon matched that of the rat-tendon cryosections in backscattered geometry. Collagen types I, II, and VI powders (nonfibrous) did not show any detectable SHG, indicating a lack of noncentrosymmetric crystalline structure at the molecular level. The various stages of collagen thermal denaturation were investigated in rat-tendon cryosections using SHG and bright-field imaging. Thermal denaturation resulted in the gradual destruction of the SHG signal. PMID:17130233

  10. Tendon Mineralization Is Progressive and Associated with Deterioration of Tendon Biomechanical Properties, and Requires BMP-Smad Signaling in the Mouse Achilles Tendon Injury Model

    PubMed Central

    Zhang, Kairui; Asai, Shuji; Hast, Michael W.; Liu, Min; Usami, Yu; Iwamoto, Masahiro; Soslowsky, Louis J.; Enomoto-Iwamoto, Motomi

    2016-01-01

    Ectopic tendon mineralization can develop following tendon rupture or trauma surgery. The pathogenesis of ectopic tendon mineralization and its clinical impact have not been fully elucidated yet. In this study, we utilized a mouse Achilles tendon injury model to determine whether ectopic tendon mineralization alters the biomechanical properties of the tendon and whether BMP signaling is involved in this condition. A complete transverse incision was made at the midpoint of the right Achilles tendon in 8-week-old CD1 mice and the gap was left open. Ectopic cartilaginous mass formation was found in the injured tendon by 4 weeks post-surgery and ectopic mineralization was detected at 8–10 weeks post-surgery. Ectopic mineralization grew over time and volume of the mineralized materials of 25-weeks samples was about 2.5 fold bigger than that of 10-weeks samples, indicating that injury-induced ectopic tendon mineralization is progressive. In vitro mechanical testing showed that max force, max stress and mid-substance modulus in the 25-weeks samples were significantly lower than the 10-weeks samples. We observed substantial increases in expression of bone morphogenetic protein family genes in injured tendons 1 week post-surgery. Immunohistochemical analysis showed that phosphorylation of both Smad1 and Smad3 were highly increased in injured tendons as early as 1 week post-injury and remained high in ectopic chondrogenic lesions 4 weeks post-injury. Treatment with the BMP receptor kinase inhibitor (LDN193189) significantly inhibited injury-induced tendon mineralization. These findings indicate that injury-induced ectopic tendon mineralization is progressive, involves BMP signaling and associated with deterioration of tendon biomechanical properties. PMID:26825318

  11. Angiopoietin-like 4 promotes angiogenesis in the tendon and is increased in cyclically loaded tendon fibroblasts.

    PubMed

    Mousavizadeh, Rouhollah; Scott, Alex; Lu, Alex; Ardekani, Gholamreza S; Behzad, Hayedeh; Lundgreen, Kirsten; Ghaffari, Mazyar; McCormack, Robert G; Duronio, Vincent

    2016-06-01

    Angiopoietin-like 4 (ANGPTL4) modulates tendon neovascularization. Cyclic loading stimulates the activity of transforming growth factor-β and hypoxia-inducible factor 1α and thereby increases the expression and release of ANGPTL4 from human tendon cells. Targeting ANGPTL4 and its regulatory pathways is a potential avenue for regulating tendon vascularization to improve tendon healing or adaptation. The mechanisms that regulate angiogenic activity in injured or mechanically loaded tendons are poorly understood. The present study examined the potential role of angiopoietin-like 4 (ANGPTL4) in the angiogenic response of tendons subjected to repetitive mechanical loading or injury. Cyclic stretching of human tendon fibroblasts stimulated the expression and release of ANGPTL4 protein via transforming growth factor-β (TGF-β) and hypoxia-inducible factor 1α (HIF-1α) signalling, and the released ANGPTL4 was pro-angiogenic. Angiogenic activity was increased following ANGPTL4 injection into mouse patellar tendons, whereas the patellar tendons of ANGPTL4 knockout mice displayed reduced angiogenesis following injury. In human rotator cuff tendons, the expression of ANGPTL4 was correlated with the density of tendon endothelial cells. To our knowledge, this is the first study characterizing a role of ANGPTL4 in the tendon. ANGPTL4 may assist in the regulation of vascularity in the injured or mechanically loaded tendon. TGF-β and HIF-1α comprise two signalling pathways that modulate the expression of ANGPTL4 by mechanically stimulated tendon fibroblasts and, in the future, these could be manipulated to influence tendon healing or adaptation. © 2015 The Authors. The Journal of Physiology © 2015 The Physiological Society.

  12. A wrist tendon travel assessment of hand movements associated with industrial repetitive activities.

    PubMed

    Ugbolue, U Chris; Nicol, Alexander C

    2012-01-01

    To investigate slow and fast paced industrial activity hand repetitive movements associated with carpal tunnel syndrome where movements are evaluated based on finger and wrist tendon travel measurements. Nine healthy subjects were recruited for the study aged between 23 and 33 years. Participants mimicked an industrial repetitive task by performing the following activities: wrist flexion and extension task, palm open and close task; and pinch task. Each task was performed for a period of 5 minutes at a slow (0.33 Hz) and fast (1 Hz) pace for a duration of 3 minutes and 2 minutes respectively. Tendon displacement produced higher flexor digitorum superficialis (FDS) tendon travel when compared to the flexor digitorum profundus (FDP) tendons. The left hand mean (SD) tendon travel for the FDS tendon and FDP tendon were 11108 (5188) mm and 9244 (4328) mm while the right hand mean tendon travel (SD) for the FDS tendon and FDP tendon were 9225 (3441) mm and 7670 (2856) mm respectively. Of the three tasks mimicking an industrial repetitive activity, the wrist flexion and extension task produced the most tendon travel. The findings may be useful to researchers in classifying the level of strenuous activity in relation to tendon travel.

  13. Doppler ultrasonography of the anterior knee tendons in elite badminton players: colour fraction before and after match.

    PubMed

    Koenig, M J; Torp-Pedersen, S; Boesen, M I; Holm, C C; Bliddal, H

    2010-02-01

    Anterior knee tendon problems are seldom reported in badminton players although the game is obviously stressful to the lower extremities. Painful anterior knee tendons are common among elite badminton players. The anterior knee tendons exhibit colour Doppler activity. This activity increases after a match. Painful tendons have more Doppler activity than tendons without pain. Cohort study. 72 elite badminton players were interviewed about training, pain and injuries. The participants were scanned with high-end ultrasound equipment. Colour Doppler was used to examine the tendons of 64 players before a match and 46 players after a match. Intratendinous colour Doppler flow was measured as colour fraction (CF). The tendon complex was divided into three loci: the quadriceps tendon, the proximal patellar tendon and the insertion on the tibial tuberosity. Interview: Of the 72 players, 62 players had problems with 86 tendons in the lower extremity. Of these 86 tendons, 48 were the anterior knee tendons. Ultrasound: At baseline, the majority of players (87%) had colour Doppler flow in at least one scanning position. After a match, the percentage of the knee complexes involved did not change. CF increased significantly in the dominant leg at the tibial tuberosity; single players had a significantly higher CF after a match at the tibial tuberosity and in the patellar tendon both before and after a match. Painful tendons had the highest colour Doppler activity. Most elite badminton players had pain in the anterior knee tendons and intratendinous Doppler activity both before and after match. High levels of Doppler activity were associated with self-reported ongoing pain.

  14. Effects of running on human Achilles tendon length-tension properties in the free and gastrocnemius components.

    PubMed

    Lichtwark, Glen A; Cresswell, Andrew G; Newsham-West, Richard J

    2013-12-01

    The elastic properties of the human Achilles tendon are important for locomotion; however, in vitro tests suggest that repeated cyclic contractions lead to tendon fatigue - an increase in length in response to stress applied. In vivo experiments have not, however, demonstrated mechanical fatigue in the Achilles tendon, possibly due to the limitations of using two-dimensional ultrasound imaging to assess tendon strain. This study used freehand three-dimensional ultrasound (3DUS) to determine whether the free Achilles tendon (calcaneus to soleus) or the gastrocnemius tendon (calcaneus to gastrocnemius) demonstrated tendon fatigue after running exercise. Participants (N=9) underwent 3DUS scans of the Achilles tendon during isometric contractions at four ankle torque levels (passive, and 14, 42 and 70 N m) before and after a 5 km run at a self-selected pace (10-14 km h(-1)). Running had a significant main effect on the length of the free Achilles tendon (P<0.01) with a small increase in length across the torque range. However, the mean lengthening effect was small (<1%) and was not accompanied by a change in free tendon stiffness. There was no significant change in the length of the gastrocnemius tendon or the free tendon cross-sectional area. While the free tendon was shown to lengthen, the lack of change in stiffness suggests the tendon exhibited mechanical creep rather than fatigue. These effects were much smaller than those predicted from in vitro experiments, possibly due to the different loading profile encountered and the ability of the tendon to repair in vivo.

  15. Tendon-Holding Capacities of Two Newly Designed Implants for Tendon Repair: An Experimental Study on the Flexor Digitorum Profundus Tendon of Sheep

    PubMed Central

    Ağır, İsmail; Aytekin, Mahmut Nedim; Başçı, Onur; Çaypınar, Barış; Erol, Bülent

    2014-01-01

    Background: Two main factors determine the strength of tendon repair; the tensile strength of material and the gripping capacity of a suture configuration. Different repair techniques and suture materials were developed to increase the strength of repairs but none of techniques and suture materials seem to provide enough tensile strength with safety margins for early active mobilization. In order to overcome this problem tendon suturing implants are being developed. We designed two different suturing implants. The aim of this study was to measure tendon-holding capacities of these implants biomechanically and to compare them with frequently used suture techniques Materials and Methods: In this study we used 64 sheep flexor digitorum profundus tendons. Four study groups were formed and each group had 16 tendons. We applied model 1 and model 2 implant to the first 2 groups and Bunnell and locking-loop techniques to the 3rd and 4th groups respectively by using 5 Ticron sutures. Results: In 13 tendons in group 1 and 15 tendons in group 2 and in all tendons in group 3 and 4, implants and sutures pulled out of the tendon in longitudinal axis at the point of maximum load. The mean tensile strengths were the largest in group 1 and smallest in group 3. Conclusion: In conclusion, the new stainless steel tendon suturing implants applied from outside the tendons using steel wires enable a biomechanically stronger repair with less tendon trauma when compared to previously developed tendon repair implants and the traditional suturing techniques. PMID:25067965

  16. Implications of obesity for tendon structure, ultrastructure and biochemistry: a study on Zucker rats.

    PubMed

    Biancalana, Adriano; Velloso, Lício Augusto; Taboga, Sebastião Roberto; Gomes, Laurecir

    2012-02-01

    The extracellular matrix consists of collagen, proteoglycans and non-collagen proteins. The incidence of obesity and associated diseases is currently increasing in developed countries. Obesity is considered to be a disease of modern times, and genes predisposing to the disease have been identified in humans and animals. The objective of the present study was to compare the morphological and biochemical aspects of the deep digital flexor tendon of lean (Fa/Fa or Fa/fa) and genetically obese (fa/fa) Zucker rats. Ultrastructural analysis showed the presence of lipid droplets in both groups, whereas disorganized collagen fibril bundles were observed in obese animals. Lean animals presented a larger amount of non-collagen proteins and glycosaminoglycans than obese rats. We propose that the overweight and lesser physical activity in obese animals may have provoked the alterations in the composition and organization of extracellular matrix components but a genetic mechanism cannot be excluded. These alterations might be related to organizational and structural modifications in the collagen bundles that influence the mechanical properties of tendons and the progression to a pathological state. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. Osmotic pressure induced tensile forces in tendon collagen

    NASA Astrophysics Data System (ADS)

    Masic, Admir; Bertinetti, Luca; Schuetz, Roman; Chang, Shu-Wei; Metzger, Till Hartmut; Buehler, Markus J.; Fratzl, Peter

    2015-01-01

    Water is an important component of collagen in tendons, but its role for the function of this load-carrying protein structure is poorly understood. Here we use a combination of multi-scale experimentation and computation to show that water is an integral part of the collagen molecule, which changes conformation upon water removal. The consequence is a shortening of the molecule that translates into tensile stresses in the range of several to almost 100 MPa, largely surpassing those of about 0.3 MPa generated by contractile muscles. Although a complete drying of collagen would be relevant for technical applications, such as the fabrication of leather or parchment, stresses comparable to muscle contraction already occur at small osmotic pressures common in biological environments. We suggest, therefore, that water-generated tensile stresses may play a role in living collagen-based materials such as tendon or bone.

  18. Architecture and functional ecology of the human gastrocnemius muscle-tendon unit.

    PubMed

    Butler, Erin E; Dominy, Nathaniel J

    2016-04-01

    The gastrocnemius muscle-tendon unit (MTU) is central to human locomotion. Structural variation in the human gastrocnemius MTU is predicted to affect the efficiency of locomotion, a concept most often explored in the context of performance activities. For example, stiffness of the Achilles tendon varies among individuals with different histories of competitive running. Such a finding highlights the functional variation of individuals and raises the possibility of similar variation between populations, perhaps in response to specific ecological or environmental demands. Researchers often assume minimal variation in human populations, or that industrialized populations represent the human species as well as any other. Yet rainforest hunter-gatherers, which often express the human pygmy phenotype, contradict such assumptions. Indeed, the human pygmy phenotype is a potential model system for exploring the range of ecomorphological variation in the architecture of human hindlimb muscles, a concept we review here. © 2015 Anatomical Society.

  19. [Effects of Gravity on Attachment of Tendon to Bone

    NASA Technical Reports Server (NTRS)

    Johnson, Roger B.

    1997-01-01

    We have received and processed all samples for either light or scanning electron microscopic analysis and have completed the histomorphometric analysis. We have characterized the changes caused by spaceflight to tendon attachments to the calcaneus, tibia, fibula and femur and compared them to hindlimbs and forelimbs from NIH.RZ. Soleus muscle histomorphometry has also been completed. Our results suggest severe osteoporosis in the femur, fibula and tibia of animals coincident to spaceflight, which had not resolved after 4-5 days following return to earth. This was evident at all sites, including sites of tendon attachments. This atrophy was not evident in the calcaneus. No muscle atrophy was evident. Comparison of scanning photomicrographs of flight animals with other lactating animals demonstrated structural similarities and suggested that it might be worthwhile to assess whether lactation is a factor in development of the osteoporosis in the spaceflight animals. In addition, evaluation of total calcium utilization by spaceflight animals would be beneficial.

  20. Monitoring tissue formation and organization of engineered tendon by optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Bagnaninchi, P. O.; Yang, Y.; Maffulli, N.; Wang, R. K.; El Haj, A.

    2006-02-01

    The uniaxial orientation and bundle formation of collagen fibres determine the mechanical properties of tendons. Thus the particular challenge of tendon tissue engineering is to build the tissue with a highly organized structure of collagen fibres. Ultimately the engineered construct will be used as autologous grafts in tendon surgery, withstanding physiological loading. We grew pig tenocytes in porous chitosan scaffolds with multiple microchannels of 250-500 μm. The cell proliferation and production of extra-cellular matrix (ECM) within the scaffolds have been successfully monitored by Optical Coherence Tomography (OCT), a bench-top OCT system equipped with a broadband light source centred at 1300 nm. Under sterile condition, the measurements were performed on-line and in a non-destructive manner. In addition, a novel method based on OCT imaging, which calculates the occupation ratio of the microchannel derived from the scattered intensity has been developed. It is confirmed that the occupation ratio is correlated to cell proliferation and ECM production in the scaffolds. Thus this method has been utilised to assess the effect of different culture conditions on the tissue formation. The use of a perfusion bioreactor has resulted in a significantly (p<1e -3) higher cell proliferation and matrix production.

  1. Quantitative ultrasound method for assessing stress-strain properties and the cross-sectional area of Achilles tendon

    NASA Astrophysics Data System (ADS)

    Du, Yi-Chun; Chen, Yung-Fu; Li, Chien-Ming; Lin, Chia-Hung; Yang, Chia-En; Wu, Jian-Xing; Chen, Tainsong

    2013-12-01

    The Achilles tendon is one of the most commonly observed tendons injured with a variety of causes, such as trauma, overuse and degeneration, in the human body. Rupture and tendinosis are relatively common for this strong tendon. Stress-strain properties and shape change are important biomechanical properties of the tendon to assess surgical repair or healing progress. Currently, there are rather limited non-invasive methods available for precisely quantifying the in vivo biomechanical properties of the tendons. The aim of this study was to apply quantitative ultrasound (QUS) methods, including ultrasonic attenuation and speed of sound (SOS), to investigate porcine tendons in different stress-strain conditions. In order to find a reliable method to evaluate the change of tendon shape, ultrasound measurement was also utilized for measuring tendon thickness and compared with the change in tendon cross-sectional area under different stress. A total of 15 porcine tendons of hind trotters were examined. The test results show that the attenuation and broadband ultrasound attenuation decreased and the SOS increased by a smaller magnitude as the uniaxial loading of the stress-strain upon tendons increased. Furthermore, the tendon thickness measured with the ultrasound method was significantly correlated with tendon cross-sectional area (Pearson coefficient = 0.86). These results also indicate that attenuation of QUS and ultrasonic thickness measurement are reliable and potential parameters for assessing biomechanical properties of tendons. Further investigations are needed to warrant the application of the proposed method in a clinical setting.

  2. Comparison of Autograft and Allograft with Surface Modification for Flexor Tendon Reconstruction: A Canine in Vivo Model.

    PubMed

    Wei, Zhuang; Reisdorf, Ramona L; Thoreson, Andrew R; Jay, Gregory D; Moran, Steven L; An, Kai-Nan; Amadio, Peter C; Zhao, Chunfeng

    2018-04-04

    Flexor tendon injury is common, and tendon reconstruction is indicated clinically if the primary repair fails or cannot be performed immediately after tendon injury. The purpose of the current study was to compare clinically standard extrasynovial autologous graft (EAG) tendon and intrasynovial allogeneic graft (IAG) that had both undergone biolubricant surface modification in a canine in vivo model. Twenty-four flexor digitorum profundus (FDP) tendons from the second and fifth digits of 12 dogs were used for this study. In the first phase, a model of failed FDP tendon repair was created. After 6 weeks, the ruptured FDP tendons with a scarred digit were reconstructed with the use of either EAG or IAG tendons treated with carbodiimide-derivatized hyaluronic acid and lubricin. At 12 weeks after tendon reconstruction, the digits were harvested for functional, biomechanical, and histologic evaluations. The tendon failure model was a clinically relevant and reproducible model for tendon reconstruction. The IAG group demonstrated improved digit function with decreased adhesion formation, lower digit work of flexion, and improved graft gliding ability compared with the EAG group. However, the IAG group had decreased healing at the distal tendon-bone junction. Our histologic findings verified the biomechanical evaluations and, further, showed that cellular repopulation of allograft at 12 weeks after reconstruction is still challenging. FDP tendon reconstruction using IAG with surface modification has some beneficial effects for reducing adhesions but demonstrated inferior healing at the distal tendon-bone junction compared with EAG. These mixed results indicate that vitalization and turnover acceleration are crucial to reducing failure of reconstruction with allograft. Flexor tendon reconstruction is a common surgical procedure. However, postoperative adhesion formation may lead to unsatisfactory clinical outcomes. In this study, we developed a potential flexor tendon allograft using chemical and tissue-engineering approaches. This technology could improve function following tendon reconstruction.

  3. A structure-based extracellular matrix expansion mechanism of fibrous tissue growth.

    PubMed

    Kalson, Nicholas S; Lu, Yinhui; Taylor, Susan H; Starborg, Tobias; Holmes, David F; Kadler, Karl E

    2015-05-20

    Embryonic growth occurs predominately by an increase in cell number; little is known about growth mechanisms later in development when fibrous tissues account for the bulk of adult vertebrate mass. We present a model for fibrous tissue growth based on 3D-electron microscopy of mouse tendon. We show that the number of collagen fibrils increases during embryonic development and then remains constant during postnatal growth. Embryonic growth was explained predominately by increases in fibril number and length. Postnatal growth arose predominately from increases in fibril length and diameter. A helical crimp structure was established in embryogenesis, and persisted postnatally. The data support a model where the shape and size of tendon is determined by the number and position of embryonic fibroblasts. The collagen fibrils that these cells synthesise provide a template for postnatal growth by structure-based matrix expansion. The model has important implications for growth of other fibrous tissues and fibrosis.

  4. Patellar tendon re-rupture on the opposite end of the previous site of surgical repair

    PubMed Central

    KOH, Bryan Thean Howe; SAYAMPANATHAN, Andrew A; LEE, Keng Thiam

    2017-01-01

    We describe a rare case of a patellar tendon “re-rupture” at the opposite end of a previous proximal tendon repair. A 32-year-old male with a history of surgically repaired right proximal patellar tendon rupture presented with an acute non-traumatic right knee pain and instability during sports. Magnetic resonance imaging confirmed a complete rupture of his distal patellar tendon at the tibial tuberosity. The patellar tendon was repaired using two 5.5 mm BioCorkscrews (Arthrex) inserted into the tibial tuberosity; the tendon was stitched with the No. 2 fiberwires using Krackow technique. As the patellar tendon was degenerative, the repair was augmented with a semitendinosus tendon harvested using an open tendon stripper, leaving the distal attachment intact. At 2.6 years followup he had mild anterior knee pain, range of motion 0-130° and was able to squat. MRI scan done at followup revealed good healing of repaired patellar tendon. PMID:28566788

  5. Ultrasonographic findings of shoulder teno-muscular structures in symptomatic and asymptomatic dogs.

    PubMed

    Barella, Gabriele; Lodi, Matteo; Faverzani, Stefano

    2017-11-14

    B-mode sonographic evaluation of shoulder joint in dogs provides qualitative information concerning mainly tendon and muscles structures. Although the sonographic findings of tenomuscular lesions have been described previously, their frequency in symptomatic and asymptomatic patients has not been reported yet. Aim of the study was to describe and compare qualitative ultrasonographic findings of shoulder joint in clinically symptomatic and asymptomatic dogs and to speculate which lesions might be considered major responsible for lameness. Fifty-two dogs with shoulder lameness and 58 asymptomatic dogs (both with unremarkable radiographic findings) underwent ultrasonographic B-mode examination of the scapulohumeral joint. Lesions detected were recorded and statistically compared between groups. Significant differences between groups were observed for the number of ultrasonographic abnormalities detected and for fluid accumulation, biceps brachii tendon (BT) lesions and bone surface irregularities. Sonography was considered useful for the determination of lesions absence and for the detection of BT lesions, fluid accumulation, muscle lacerations and bone surface irregularities. The odds for symptomatic dogs were greater than for asymptomatic patients to ultrasonographically diagnose BT lesions, fluid accumulation and bone surface irregularities. Ultrasound has proven to be a useful tool in the evaluation of tenomusculoskeletal structures of shoulder in dogs with unremarkable radiographic findings. Our results suggest that ultrasonography is useful in the diagnosis of tendon abnormalities, fluid accumulation, muscle lacerations and bone surface irregularities as potential contributors to shoulder lameness in dogs.

  6. The failure mode of two reabsorbable fixation systems: Swivelock with Fibertape versus Bio-Corkscrew with Fiberwire in bovine rotator cuff.

    PubMed

    De Carli, Angelo; Lanzetti, Riccardo Maria; Monaco, Edoardo; Labianca, Luca; Mossa, Luigi; Ferretti, Andrea; Feretti, Andrea

    2012-11-01

    Despite technical advances in rotator cuff surgery, recurrent or persistent defects in the repaired tendon continue to occur. The improved strength of sutures and suture anchors has shown that the most common site of failure is the suture-tendon interface. The purpose of this study was to compare two different types of repair under both cyclic and load-to-failure conditions. The hypothesis is that the use of a fixation system with knotless anchor and taped suture results in better biomechanical performance, under both cyclic and load-to-failure conditions. Thirty bovine shoulder specimens were randomly assigned to two group tests: the Swivelock 5-mm anchor with Fibertape (Group A) and the Bio-Corkscrew 5 mm with Fiberwire (Group B). We simulated the reconstruction of a rotator cuff tear with a single-row technique, performing a tenodesis with types A and B fixation. Each specimen underwent cyclic testing from 5 to 30 N for 30 cycles, followed by load-to-failure testing, in order to calculate the ultimate failure load (UFL). Load-to-failure tests revealed a significantly higher UFL in Group A than in Group B. Wire fixing failed at the anchor loop whereas tape fixing failed at the sutures, suture-tendon interface, and anchors. Cyclic testing revealed no significantly greater slippage between the two groups. Stiffness values were not statistically significantly different. In all cases, tendons remained intact until the end of the cyclic testing. The tape structure is biomechanically stronger than the wire structure.

  7. A review on animal models and treatments for the reconstruction of Achilles and flexor tendons.

    PubMed

    Bottagisio, Marta; Lovati, Arianna B

    2017-03-01

    Tendon is a connective tissue mainly composed of collagen fibers with peculiar mechanical properties essential to functional movements. The increasing incidence of tendon traumatic injuries and ruptures-associated or not with the loss of tissue-falls on the growing interest in the field of tissue engineering and regenerative medicine. The use of animal models is mandatory to deepen the knowledge of the tendon healing response to severe damages or acute transections. Thus, the selection of preclinical models is crucial to ensure a successful translation of effective and safe innovative treatments to the clinical practice. The current review is focused on animal models of tendon ruptures and lacerations or defective injuries with large tissue loss that require surgical approaches or grafting procedures. Data published between 2000 and 2016 were examined. The analyzed articles were compiled from Pub Med-NCBI using search terms, including animal model(s) AND tendon augmentation OR tendon substitute(s) OR tendon substitution OR tendon replacement OR tendon graft(s) OR tendon defect(s) OR tendon rupture(s). This article presents the existing preclinical models - considering their advantages and disadvantages-in which translational progresses have been made by using bioactive sutures or tissue engineering that combines biomaterials with cells and growth factors to efficiently treat transections or large defects of Achilles and flexor tendons.

  8. Effects of high loading by eccentric triceps surae training on Achilles tendon properties in humans.

    PubMed

    Geremia, Jeam Marcel; Baroni, Bruno Manfredini; Bobbert, Maarten Frank; Bini, Rodrigo Rico; Lanferdini, Fabio Juner; Vaz, Marco Aurélio

    2018-06-01

    To document the magnitude and time course of human Achilles tendon adaptations (i.e. changes in tendon morphological and mechanical properties) during a 12-week high-load plantar flexion training program. Ultrasound was used to determine Achilles tendon cross-sectional area (CSA), length and elongation as a function of plantar flexion torque during voluntary plantar flexion. Tendon force-elongation and stress-strain relationships were determined before the start of training (pre-training) and after 4 (post-4), 8 (post-8) and 12 (post-12) training weeks. At the end of the training program, maximum isometric force had increased by 49% and tendon CSA by 17%, but tendon length, maximal tendon elongation and maximal strain were unchanged. Hence, tendon stiffness had increased by 82%, and so had Young's modulus, by 86%. Significant changes were first detected at post-4 in stiffness (51% increase) and Young's modulus (87% increase), and at post-8 in CSA (15% increase). Achilles tendon material properties already improved after 4 weeks of high-load training: stiffness increased while CSA remained unchanged. Tendon hypertrophy (increased CSA) was observed after 8 training weeks and contributed to a further increase in Achilles tendon stiffness, but tendon stiffness increases were mostly caused by adaptations in tissue properties.

  9. Grasp Assist Device with Shared Tendon Actuator Assembly

    NASA Technical Reports Server (NTRS)

    Ihrke, Chris A. (Inventor); Bergelin, Bryan J. (Inventor); Bridgwater, Lyndon (Inventor)

    2015-01-01

    A grasp assist device includes a glove with first and second tendon-driven fingers, a tendon, and a sleeve with a shared tendon actuator assembly. Tendon ends are connected to the respective first and second fingers. The actuator assembly includes a drive assembly having a drive axis and a tendon hook. The tendon hook, which defines an arcuate surface slot, is linearly translatable along the drive axis via the drive assembly, e.g., a servo motor thereof. The flexible tendon is routed through the surface slot such that the surface slot divides the flexible tendon into two portions each terminating in a respective one of the first and second ends. The drive assembly may include a ball screw and nut. An end cap of the actuator assembly may define two channels through which the respective tendon portions pass. The servo motor may be positioned off-axis with respect to the drive axis.

  10. Three-dimensional study of pectoralis major muscle and tendon architecture.

    PubMed

    Fung, Lillia; Wong, Brian; Ravichandiran, Kajeandra; Agur, Anne; Rindlisbacher, Tim; Elmaraghy, Amr

    2009-05-01

    A thorough understanding of the normal structural anatomy of the pectoralis major (PM) is of paramount importance in the planning of PM tendon transfers or repairs following traumatic PM tears. However, there is little consensus regarding the complex musculotendinous architecture of the PM in the anatomic or surgical literature. The purpose of this study is to model and quantify the three-dimensional architecture of the pectoralis muscle and tendon. Eleven formalin embalmed cadaveric specimens were examined: five (2M/3F) were serially dissected, digitized, and modeled in 3D using Autodesk Maya; six (4M/2F) were dissected and photographed. The PM tendon consisted of longer anterior and shorter posterior layers that were continuous inferiorly. The muscle belly consisted of an architecturally uniform clavicular head (CH) and a segmented sternal head (SH) with 6-7 segments. The most inferior SH segment in all specimens was found to fold anteriorly forming a trough that cradled the inferior aspect of the adjacent superior segment. No twisting of either the PM muscle or tendon was noted. Within the CH, the fiber bundle lengths (FBL) were found to increase from superior to inferior, whereas the mean FBLs of SH were greatest in segments 3-5 found centrally. The mean lateral pennation angle was greater in the CH (29.4 +/- 6.9 degrees ) than in the SH (20.6 +/- 2.7 degrees ). The application of these findings could form the basis of future studies to optimize surgical planning and functional recovery of repair/reconstruction procedures.

  11. Cyclic tension promotes fibroblastic differentiation of human MSCs cultured on collagen-fibre scaffolds.

    PubMed

    Qiu, Yongzhi; Lei, Jennifer; Koob, Thomas J; Temenoff, Johnna S

    2016-12-01

    Mesenchymal stem cells (MSCs) have been suggested as a potential cell source for tendon/ligament tissue engineering. Extrinsic cues, such as the chemical and physical properties of scaffolds, as well as external forces, play an important role in fibroblastic differentiation of these cells. In this study, we employed a collagen-fibre scaffold that mimics the chemical and fibrous structure and mechanical properties of tendon/ligament, and studied how imparting cyclic tension to these fibrous collagen scaffolds affects tendon/ligament fibroblastic differentiation of MSCs. Human MSCs attached and spread on the surface of the scaffolds, and appeared aligned along the fibres 24 h after seeding. Cyclic tension was then applied to cell-laden scaffolds over a period of 14 days (10% strain, 1 Hz, 3 h on/3 h off). Real time RT-PCR analysis indicated that scleraxis, a transcription factor associated with the tendon fibroblast phenotype, was found to be significantly upregulated only under cyclic tension. Immunohistochemical staining demonstrated that MSCs cultured under cyclic tension after 14 days secreted more extracellular matrix, including collagen I, collagen III and tenascin-C, compared to constructs in static culture, after 14 days in vitro. Our data indicate that cyclic tension can promote fibroblastic differentiation of MSCs in these fibrous collagen-based scaffolds, which may have significant applications in the development of tissue-engineered graft alternatives for tendon and ligament injuries. Copyright © 2014 John Wiley & Sons, Ltd. Copyright © 2014 John Wiley & Sons, Ltd.

  12. Multiple tendon ruptures of unknown etiology.

    PubMed

    Axibal, Derek P; Anderson, John G

    2013-10-01

    Tendon ruptures are common findings in foot and ankle practice. The etiology of tendon ruptures tends to be multifactorial-usually due to a combination of trauma, effects of systemic diseases, adverse effects of medications, and obesity. We present an unusual case of right Achilles tendinitis, left Achilles tendon rupture, bilateral peroneus longus tendon rupture, and left peroneus brevis tendon rupture of unknown etiology. This case report highlights the need for research for other possible, lesser known etiologies of tendon pathology. Therapeutic, Level IV, Case Study.

  13. SAFE LOCALIZATION FOR PLACEMENT OF PERCUTANEOUS PINS IN THE CALCANEUS.

    PubMed

    Labronici, Pedro José; Pereira, Diogo do Nascimento; Pilar, Pedro Henrique Vargas Moreira; Franco, José Sergio; Serra, Marcos Donato; Cohen, José Carlos; Bitar, Rogério Carneiro

    2012-01-01

    To determine the areas presenting risk in six zones of the calcaneus, and to quantify the risks of injury to the anatomical structures (artery, vein, nerve and tendon). Fifty-three calcanei from cadavers were used, divided into three zones and each subdivided in two areas (upper and lower) by means of a longitudinal line through the calcaneus. The risk of injury to the anatomical structures in relation to each Kirschner wire was determined using a graded system according to the Licht classification. The total risk of injury to the anatomical structures through placement of more than one wire was quantified using the additive law of probabilities and the product law for independent events. The injury risk calculation according to the Licht classification showed that the highest risk of injury to the artery or vein was in zone IA (43%), in relation to injuries to nerves and tendons (13% and 0%, respectively). This study made it possible to identify the most vulnerable anatomical structures and quantify the risk of injury to the calcaneus.

  14. Structural Sizing Methodology for the Tendon-Actuated Lightweight In-Space MANipulator (TALISMAN) System

    NASA Technical Reports Server (NTRS)

    Jones, Thomas C.; Dorsey, John T.; Doggett, William R.

    2015-01-01

    The Tendon-Actuated Lightweight In-Space MANipulator (TALISMAN) is a versatile long-reach robotic manipulator that is currently being tested at NASA Langley Research Center. TALISMAN is designed to be highly mass-efficient and multi-mission capable, with applications including asteroid retrieval and manipulation, in-space servicing, and astronaut and payload positioning. The manipulator uses a modular, periodic, tension-compression design that lends itself well to analytical modeling. Given the versatility of application for TALISMAN, a structural sizing methodology was developed that could rapidly assess mass and configuration sensitivities for any specified operating work space, applied loads and mission requirements. This methodology allows the systematic sizing of the key structural members of TALISMAN, which include the truss arm links, the spreaders and the tension elements. This paper summarizes the detailed analytical derivations and methodology that support the structural sizing approach and provides results from some recent TALISMAN designs developed for current and proposed mission architectures.

  15. The Effects of Bio-Lubricating Molecules on Flexor Tendon Reconstruction in A Canine Allograft Model In Vivo

    PubMed Central

    Zhao, Chunfeng; Wei, Zhuang; Kirk, Ramona L.; Thoreson, Andrew R.; Jay, Gregory D.; Moran, Steven L.; An, Kai-Nan; Amadio, Peter C.

    2014-01-01

    Background Using allograft is an attractive alternative for flexor tendon reconstruction because of the lack of donor morbidity, and better matching to the intrasynovial environment. The purpose of this study was to use biolubricant molecules to modify the graft surface to decrease adhesions and improve digit function. Methods 28 flexor digitorum profundus (FDP) tendons from the 2nd and 5th digits of 14 dogs were first lacerated and repaired to create a model with repair failure and scar digit for tendon reconstruction. Six weeks after the initial surgery, the tendons were reconstructed with FDP allograft tendons obtained from canine cadavers. One graft tendon in each dog was treated with saline as a control and the other was treated with gelatin, carbodiimide derivatized, hyaluronic acid and lubricin (cd-HA-Lubricin). Six weeks postoperatively, digit function, graft mechanics, and biology were analyzed. Results Allograft tendons treated with cd-HA-Lubricin had decreased adhesions at the proximal tendon/graft repair and within flexor sheath, improved digit function, and increased graft gliding ability. The treatment also reduced the strength at the distal tendon to bone repair, but the distal attachment rupture rate was similar for both graft types. Histology showed that viable cells migrated to the allograft, but these were limited to the tendon surface. Conclusion cd-HA-Lubricin treatment of tendon allograft improves digit functional outcomes after flexor tendon reconstruction. However, delayed bone-tendon healing should be a caution. Furthermore, the cell infiltration into the allograft tendons substance should be a target for future studies, to shorten the allograft self-regeneration period. PMID:24445876

  16. Biomechanical and histological effects of augmented soft tissue mobilization therapy on achilles tendinopathy in a rabbit model.

    PubMed

    Imai, Kan; Ikoma, Kazuya; Chen, Qingshan; Zhao, Chunfeng; An, Kai-Nan; Gay, Ralph E

    2015-02-01

    Augmented soft tissue mobilization (ASTM) has been used to treat Achilles tendinopathy and is thought to promote collagen fiber realignment and hasten tendon regeneration. The objective of this study was to evaluate the biomechanical and histological effects of ASTM therapy on rabbit Achilles tendons after enzymatically induced injury. This study was a non-human bench controlled research study using a rabbit model. Both Achilles tendons of 12 rabbits were injected with collagenase to produce tendon injury simulating Achilles tendinopathy. One side was then randomly allocated to receive ASTM, while the other received no treatment (control). ASTM was performed on the Achilles tendon on postoperative days 21, 24, 28, 31, 35, and 38. Tendons were harvested 10 days after treatment and examined with dynamic viscoelasticity and light microscopy. Cross-sectional area in the treated tendons was significantly greater than in controls. Storage modulus tended to be lower in the treated tendons but elasticity was not significantly increased. Loss modulus was significantly lower in the treated tendons. There was no significant difference found in tangent delta (loss modulus/storage modulus). Microscopy of control tendons showed that the tendon fibers were wavy and type III collagen was well stained. The tendon fibers of the augmented soft tissue mobilization treated tendons were not wavy and type III collagen was not prevalent. Biomechanical and histological findings showed that the Achilles tendons treated with ASTM had better recovery of biomechanical function than did control tendons. Copyright © 2015 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.

  17. Augmentation of Distal Biceps Repair With an Acellular Dermal Graft Restores Native Biomechanical Properties in a Tendon-Deficient Model.

    PubMed

    Conroy, Christine; Sethi, Paul; Macken, Craig; Wei, David; Kowalsky, Marc; Mirzayan, Raffy; Pauzenberger, Leo; Dyrna, Felix; Obopilwe, Elifho; Mazzocca, Augustus D

    2017-07-01

    The majority of distal biceps tendon injuries can be repaired in a single procedure. In contrast, complete chronic tears with severe tendon substance deficiency and retraction often require tendon graft augmentation. In cases with extensive partial tears of the distal biceps, a human dermal allograft may be used as an alternative to restore tendon thickness and biomechanical integrity. Dermal graft augmentation will improve load to failure compared with nonaugmented repair in a tendon-deficient model. Controlled laboratory study. Thirty-six matched specimens were organized into 1 of 4 groups: native tendon, native tendon with dermal graft augmentation, tendon with an attritional defect, and tendon with an attritional defect repaired with a graft. To mimic a chronic attritional biceps lesion, a defect was created by a complete tear, leaving 30% of the tendon's width intact. The repair technique in all groups consisted of cortical button and interference screw fixation. All specimens underwent cyclical loading for 3000 cycles and were then tested to failure; gap formation and peak load at failure were documented. The mean (±SD) load to failure (320.9 ± 49.1 N vs 348.8 ± 77.6 N, respectively; P = .38) and gap formation (displacement) (1.8 ± 1.4 mm vs 1.6 ± 1.1 mm, respectively; P = .38) did not differ between the native tendon groups with and without graft augmentation. In the tendon-deficient model, the mean load to failure was significantly improved with graft augmentation compared with no graft augmentation (282.1 ± 83.8 N vs 199.7 ± 45.5 N, respectively; P = .04), while the mean gap formation was significantly reduced (1.2 ± 1.0 mm vs 2.7 ± 1.4 mm, respectively; P = .04). The mean load to failure of the deficient tendon with graft augmentation (282.1 N) compared with the native tendon (348.8 N) was not significantly different ( P = .12). This indicates that the native tendon did not perform differently from the grafted deficient tendon. In a tendon-deficient, complete distal biceps rupture model, acellular dermal allograft augmentation restored the native tendon's biomechanical properties at time zero. The grafted tissue-deficient model demonstrated no significant differences in the load to failure and gap formation compared with the native tendon. As expected, dermal augmentation of attritional tendon repair increased the load to failure and stiffness as well as decreased displacement compared with the ungrafted tissue-deficient model. Tendons with their native width showed no statistical difference or negative biomechanical consequences of dermal augmentation. Dermal augmentation of the distal biceps is a biomechanically feasible option for patients with an attritionally thinned-out tendon.

  18. US appearance of partial-thickness supraspinatus tendon tears: Application of the string theory. Pictorial essay.

    PubMed

    Guerini, H; Fermand, M; Godefroy, D; Feydy, A; Chevrot, A; Morvan, G; Gault, N; Drapé, J L

    2012-02-01

    The supraspinatus tendon is composed of 5 different layers consisting of intertwining bundles. On a front portion of the tendon, the layers become coated bundles which insert on the trochanter. At the insertion, the superficial or bursal surface of the tendon corresponding to the tendon fibers in contact with the subacromial bursa can be distinguished from the deep surface corresponding to the fibers in contact with the glenohumeral joint. A tendon tear may involve partial or total disruption of the tendon fibers and is called full-thickness tear if it affects the entire tendon, and partial-thickness tear if it involves only part of the tendon. Partial-thickness tears of the supraspinatus tendon include lesions of the superficial, deep and central surface or tendon delamination.A contrast enhanced examination requires injection of contrast agent into the joint (arthrography followed by computed tomography (CT) or magnetic resonance imaging (MRI)) to study the deep surface, and injection into the subacromial bursa (bursography followed by CT) to study the superficial surface. MRI and ultrasound (US) examination allow the study of these different tendon layers without the use of contrast agent (which is not possible at CT).

  19. Lubricin Surface Modification Improves Tendon Gliding After Tendon Repair in a Canine Model in Vitro

    PubMed Central

    Taguchi, Manabu; Sun, Yu-Long; Zhao, Chunfeng; Zobitz, Mark E.; Cha, Chung-Ja; Jay, Gregory D.; An, Kai-Nan; Amadio, Peter C.

    2011-01-01

    This study investigated the effects of lubricin on the gliding of repaired flexor digitorum profundus (FDP) tendons in vitro. Canine FDP tendons were completely lacerated, repaired with a modified Pennington technique, and treated with one of the following solutions: saline, carbodiimide derivatized gelatin/hyaluronic acid (cd-HA-gelatin), carbodiimide derivatized gelatin to which lubricin was added in a second step (cd-gelatin + lubricin), or carbodiimide derivatized gelatin/HA + lubricin (cd-HA-gelatin + lubricin). After treatment, gliding resistance was measured up to 1,000 cycles of simulated flexion/extension motion. The increase in average and peak gliding resistance in cd-HA-gelatin, cd-gelatin + lubricin, and cd-HA-gelatin + lubricin tendons was less than the control tendons after 1,000 cycles (p < 0.05). The increase in average gliding resistance of cd-HA-gelatin + lubricin treated tendons was also less than that of the cd-HA-gelatin treated tendons (p < 0.05). The surfaces of the repaired tendons and associated pulleys were assessed qualitatively with scanning electron microscopy and appeared smooth after 1,000 cycles of tendon motion for the cd-HA-gelatin, cd-gelatin + lubricin, and cd-HA-gelatin + lubricin treated tendons, while that of the saline control appeared roughened. These results suggest that tendon surface modification can improve tendon gliding ability, with a trend suggesting that lubricin fixed on the repaired tendon may provide additional improvement over that provided by HA and gelatin alone. PMID:18683890

  20. Pleiotropic roles of the matricellular protein Sparc in tendon maturation and ageing

    PubMed Central

    Gehwolf, Renate; Wagner, Andrea; Lehner, Christine; Bradshaw, Amy D.; Scharler, Cornelia; Niestrawska, Justyna A.; Holzapfel, Gerhard A.; Bauer, Hans-Christian; Tempfer, Herbert; Traweger, Andreas

    2016-01-01

    Acute and chronic tendinopathies remain clinically challenging and tendons are predisposed to degeneration or injury with age. Despite the high prevalence of tendon disease in the elderly, our current understanding of the mechanisms underlying the age-dependent deterioration of tendon function remains very limited. Here, we show that Secreted protein acidic and rich in cysteine (Sparc) expression significantly decreases in healthy-aged mouse Achilles tendons. Loss of Sparc results in tendon collagen fibrillogenesis defects and Sparc−/− tendons are less able to withstand force in comparison with their respective wild type counterparts. On the cellular level, Sparc-null and healthy-aged tendon-derived cells exhibited a more contracted phenotype and an altered actin cytoskeleton. Additionally, an elevated expression of the adipogenic marker genes PPARγ and Cebpα with a concomitant increase in lipid deposits in aged and Sparc−/− tendons was observed. In summary, we propose that Sparc levels in tendons are critical for proper collagen fibril maturation and its age-related decrease, together with a change in ECM properties favors lipid accretion in tendons. PMID:27586416

  1. Phenytoin accelerates tendon healing in a rat model of Achilles tendon rupture.

    PubMed

    Hajipour, B; Navali, A M; Mohammad, S Ali; Mousavi, G; Akbari, M Gahvechi; Miyandoab, T Maleki; Roshangar, L; Saleh, B Mohammadi; Kermani, T Asvadi; Laleh, F Moutab; Ghabili, M

    2016-01-01

    Tendons are vulnerable to various types of acute or chronic injures. Different methods have been investigated to achieve better healing. Phenytoin is a drug which could stimulate fibroblasts to produce collagen. This experimental study was performed to assess the effect of phenytoin on tendon healing in a rat model of tendon rupture. Thirty healthy rats were divided into 3 groups, 1) Sham group; 2) Tendon rupture; 3) Tendon rupture+phenytoin (100 mg/kg intraperitoneally) for 21 days. On 21st day after tendon injury, the rats were anesthetized and tendon tissue was sampled for studying by light and electron microscopy. Qualitative and quantitative microscopic comparisons of the repair tissues of both groups were made on the 21st day. The results obtained from light and electron microscopy studies showed that tendon tissue healing was significantly better in phenytoin group compared to the control group (p < 0.05). Systemic administration of phenytoin may have a positive effect on tendon healing by increasing fibroblast quantity, fibrillar collagen synthesis, vascularity, and suppressing inflammation (Tab. 2, Ref. 25).

  2. Magnetic resonance imaging-controlled results of the pectoralis major tendon transfer for irreparable anterosuperior rotator cuff tears performed with standard and modified fixation techniques.

    PubMed

    Lederer, Stefan; Auffarth, Alexander; Bogner, Robert; Tauber, Mark; Mayer, Michael; Karpik, Stefanie; Matis, Nicholas; Resch, Herbert

    2011-10-01

    Irreparable ruptures of the subscapularis tendon lead to impaired function of the shoulder joint. In such cases, transfer of the pectoralis major tendon has led to encouraging results. The procedure fails periodically, typically associated with insufficient in-growth of the transferred tissue. We hypothesized that tendon harvest with chips of cancellous bone would improve the tendon-bone interface. Of 62 consecutive pectoralis tendon transfers, 54 shoulders were followed-up at an average of 35 months. In all shoulders, the transferred tendon was rerouted behind the conjoint tendon and fixed by transosseous sutures. In 29 shoulders, the tendon was harvested with a cuff of cancellous bone. In 25 shoulders, the conventional technique with sharp detachment of the tendon was used. Apart from detailed clinical examination of all shoulders, a magnetic resonance image (MRI) was available in 52 shoulders. The overall Constant score had improved from an average of 38.8 points preoperatively to 63.4 points at follow-up. Shoulders treated with the new fixation technique scored 64.4 compared with 62.2 for the conventional fixations. The MRI showed intact tendons and muscles in 80.8% of shoulders. In 7 shoulders (13.5%), the transferred tendon was ruptured. Two of these were treated with the new fixation technique. Mean patient satisfaction score was 8.2 points. A secure method of fixation that avoids secondary ruptures despite insufficiency of the transferred tendon is of great importance. Also the rerouting of the transferred tendon under the conjoined tendon is essential to imitate the natural force vector and the function of an intact subscapularis tendon. Patients in this investigation were also monitored by MRI to verify the integrity of the transferred tendon. As a salvage procedure, the pectoralis major tendon transfer provides good results in most cases. Sufficient in-growth of the transferred tissue is essential for the success of the procedure. This seems to be facilitated by both methods. Copyright © 2011 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.

  3. Changes in Achilles tendon mechanical properties following eccentric heel drop exercise are specific to the free tendon.

    PubMed

    Obst, S J; Newsham-West, R; Barrett, R S

    2016-04-01

    Mechanical loading of the Achilles tendon during isolated eccentric contractions could induce immediate and region-dependent changes in mechanical properties. Three-dimensional ultrasound was used to examine the immediate effect of isolated eccentric exercise on the mechanical properties of the distal (free tendon) and proximal (gastrocnemii) regions of the Achilles tendon. Participants (n = 14) underwent two testing sessions in which tendon measurements were made at rest and during a 30% and 70% isometric plantar flexion contractions immediately before and after either: (a) 3 × 15 eccentric heel drops or (b) 10-min rest. There was a significant time-by-session interaction for free tendon length and strain for all loading conditions (P < 0.05). Pairwise comparisons revealed a significant increase in free tendon length and strain at all contraction intensities after eccentric exercise (P < 0.05). There was no significant time-by-session interaction for the gastrocnemii (medial or lateral) aponeurosis or tendon for any of the measured parameters. Immediate changes in Achilles tendon mechanical properties were specific to the free tendon and consistent with changes due to mechanical creep. These findings suggest that the mechanical properties of the free tendon may be more vulnerable to change with exercise compared with the gastrocnemii aponeurosis or tendon. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Deficits in heel-rise height and achilles tendon elongation occur in patients recovering from an Achilles tendon rupture.

    PubMed

    Silbernagel, Karin Grävare; Steele, Robert; Manal, Kurt

    2012-07-01

    Whether an Achilles tendon rupture is treated surgically or not, complications such as muscle weakness, decrease in heel-rise height, and gait abnormalities persist after injury. The purpose of this study was to evaluate if side-to-side differences in maximal heel-rise height can be explained by differences in Achilles tendon length. Case series; level of evidence, 4. Eight patients (mean [SD] age of 46 [13] years) with acute Achilles tendon rupture and 10 healthy subjects (mean [SD] age of 28 [8] years) were included in the study. Heel-rise height, Achilles tendon length, and patient-reported outcome were measured 3, 6, and 12 months after injury. Achilles tendon length was evaluated using motion analysis and ultrasound imaging. The Achilles tendon length test-retest reliability (intraclass correlation coefficient = 0.97) was excellent. For the healthy subjects, there were no side-to-side differences in tendon length and heel-rise height. Patients with Achilles tendon ruptures had significant differences between the injured and uninjured side for both tendon length (mean [SD] difference, 2.6-3.1 [1.2-1.4] cm, P = .017-.028) and heel-rise height (mean [SD] difference, -4.1 to -6.1 [1.7-1.8] cm, P = .012-.028). There were significant negative correlations (r = -0.943, P = .002, and r = -0.738, P = .037) between the side-to-side difference in heel-rise height and Achilles tendon length at the 6- and 12-month evaluations, respectively. The side-to-side difference found in maximal heel-rise height can be explained by a difference in Achilles tendon length in patients recovering from an Achilles tendon rupture. Minimizing tendon elongation appears to be an important treatment goal when aiming for full return of function.

  5. Reconstruction of chronic achilles tendon rupture with the use of interposed tissue between the stumps.

    PubMed

    Yasuda, Toshito; Kinoshita, Mitsuo; Okuda, Ryuzo

    2007-04-01

    The gap between the tendon stumps in chronic Achilles tendon rupture has reportedly been filled with interposed scar tissue. In the authors' clinical experience, this interposed tissue is often thick and resists tension, so they considered it was possible to use the interposed tissue for reconstruction of Achilles tendon rupture. Scar tissue interposed between the tendon stumps has the capacity to form tendon-like repair tissue in patients with chronic Achilles tendon rupture. Case series; Level of evidence, 4. Six patients with chronic rupture of the Achilles tendon underwent tendon reconstruction with the use of interposed tissue between the stumps. The average time from the primary injury to surgery was 22 weeks (range, 9 to 30 weeks). Preoperative magnetic resonance imaging (MRI), histology of the interposed tissue, and clinical results were evaluated. The average postoperative follow-up period was 31 months (range, 24 to 43 months). Preoperative T2-weighted MRI in all cases revealed that chronically ruptured Achilles tendons were thickened and fusiform-shaped with diffuse intratendinous high-signal alterations throughout. Longitudinal high-signal bands were seen throughout the tendon, except at the musculotendinous junction and insertion on the calcaneus. Histologically, scar tissue interposed between the tendon stumps consisted of dense collagen fibers, and degenerative changes were not seen. After surgery, no patient had difficulty in walking or stair climbing, and all were able to perform a single-limb toe raise. The mean preoperative and postoperative American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot scores were 88.2 and 98.3 points, respectively; the difference was statistically significant (P = .0277). Interposed tissue between the tendon stumps is suitable for repair of chronic Achilles tendon rupture if preoperative MRI shows a thickened fusiform-shaped Achilles tendon with diffuse intratendinous high-signal alterations throughout.

  6. The Achilles Tendon in Healthy Subjects: An Anthropometric and Ultrasound Mapping Study.

    PubMed

    Patel, Nick N; Labib, Sameh A

    Ultrasonography is an inexpensive, fast, and reliable imaging technique widely used to assess the Achilles tendon. Although significant data exists regarding pathologic tendon changes, ultrasound data from healthy individuals are more limited. We aimed to better characterize ultrasound Achilles tendon measurements in healthy individuals and identify important correlating factors. The information collected included patient demographics, body habitus, activity level, foot dominance, and resting ankle angle. Ultrasound analysis was performed bilaterally on the Achilles tendons of 50 subjects using a high-frequency transducer to measure tendon width, thickness, cross-sectional area, and length. Males had a significantly larger mean tendon length, width, thickness, and cross-sectional area. No statistically significant difference was found in any tendon dimension between the white and black participants. Similarly, no difference was found in any tendon parameter when comparing right versus left leg dominance. Healthy subjects had a mean ankle resting angle of 45.1° ± 24° with no statistically significant difference between right and left ankles. Considering all individuals, each tendon parameter (tendon length, width, thickness, and cross-sectional area) correlated positively with subject height, weight, tibia length, and foot size. Only the Achilles cross-sectional area correlated significantly with the activity level. The resting angle of the ankle correlated positively with both tendon length and thickness. In conclusion, we found significant variations in Achilles tendon anatomy in the healthy adult population. We have thoroughly characterized significant correlations between healthy tendon dimensions and various body habitus, activity levels, and ankle parameters. Greater knowledge of the normal Achilles tendon anatomy and characterization of its variations in the healthy population will potentially allow for better pathologic diagnosis and surgical repair. Copyright © 2017 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  7. The flexor digitorum profundus "demi-tendon"--a new technique for passage of the flexor profundus tendon through the A4 pulley.

    PubMed

    Elliot, D; Khandwala, A R; Ragoowansi, R

    2001-10-01

    The flexor digitorum profundus (FDP) tendon may retract after avulsion or division in Zone 1. When treatment has been delayed, the oedematous tendon can be too swollen to pass freely through the A4 pulley. We present a new technique for dealing with this situation which depends on the "double-barrelled" nature of the distal part of the FDP tendon. One half of the tendon is excised longitudinally and the remaining "demi-tendon" is passed through the intact A4 pulley to allow tendon repair or re-attachment. This technique has been used in six cases in which passage of the FDP tendon through the A4 pulley would otherwise have been impossible. Copyright 2001 The British Society for Surgery of the Hand.

  8. INDIRECT INTELLIGENT SLIDING MODE CONTROL OF A SHAPE MEMORY ALLOY ACTUATED FLEXIBLE BEAM USING HYSTERETIC RECURRENT NEURAL NETWORKS.

    PubMed

    Hannen, Jennifer C; Crews, John H; Buckner, Gregory D

    2012-08-01

    This paper introduces an indirect intelligent sliding mode controller (IISMC) for shape memory alloy (SMA) actuators, specifically a flexible beam deflected by a single offset SMA tendon. The controller manipulates applied voltage, which alters SMA tendon temperature to track reference bending angles. A hysteretic recurrent neural network (HRNN) captures the nonlinear, hysteretic relationship between SMA temperature and bending angle. The variable structure control strategy provides robustness to model uncertainties and parameter variations, while effectively compensating for system nonlinearities, achieving superior tracking compared to an optimized PI controller.

  9. Is Soleus Muscle-Tendon-Unit Behavior Related to Ground-Force Application During the Sprint Start?

    PubMed

    Schrödter, Erik; Brüggemann, Gert-Peter; Willwacher, Steffen

    2017-04-01

    To describe the stretch-shortening behavior of ankle plantar-flexing muscle-tendon units (MTUs) during the push-off in a sprint start. Fifty-four male (100-m personal best: 9.58-12.07 s) and 34 female (100-m personal best: 11.05-14.00 s) sprinters were analyzed using an instrumented starting block and 2-dimensional high-speed video imaging. Analysis was performed separately for front and rear legs, while accounting for block obliquities and performance levels. The results showed clear signs of a dorsiflexion in the upper ankle joint (front block 15.8° ± 7.4°, 95% CI 13.2-18.2°; rear block 8.0° ± 5.7°, 95% CI 6.4-9.7°) preceding plantar flexion. When observed in their natural block settings, the athletes' block obliquity did not significantly affect push-off characteristics. It seems that the stretch-shortening-cycle-like motion of the soleus MTU has an enhancing influence on push-off force generation. This study provides the first systematic observation of ankle-joint stretch-shortening behavior for sprinters of a wide range of performance levels. The findings highlight the importance of reactive-type training for the improvement of starting performance. Nonetheless, future studies need to resolve the independent contributions of tendinous and muscle-fascicle structures to overall MTU performance.

  10. Central Tendon Injuries of Hamstring Muscles: Case Series of Operative Treatment.

    PubMed

    Lempainen, Lasse; Kosola, Jussi; Pruna, Ricard; Puigdellivol, Jordi; Sarimo, Janne; Niemi, Pekka; Orava, Sakari

    2018-02-01

    As compared with injuries involving muscle only, those involving the central hamstring tendon have a worse prognosis. Limited information is available regarding the surgical treatment of central tendon injuries of the hamstrings. To describe the operative treatment and outcomes of central tendon injuries of the hamstrings among athletes. Case series; Level of evidence, 4. Eight athletes (6 top level, 2 recreational) with central hamstring tendon injuries underwent magnetic resonance imaging and surgical treatment. The indication for surgery was recurrent (n = 6) or acute (n = 2) central hamstring tendon injury. All patients followed the same postoperative rehabilitation protocol, and return to play was monitored. Magnetic resonance imaging found a central tendon injury in all 3 hamstring muscles (long head of the biceps femoris, semimembranosus, and semitendinosus) with disrupted tendon ends. In acute and recurrent central tendon injuries, full return to play was achieved at 2.5 to 4 months. There were no adverse events during follow-up. Central tendon injuries of the hamstrings can be successfully repaired surgically after acute and recurrent ruptures.

  11. Angiogenesis in healing autogenous flexor-tendon grafts.

    PubMed

    Gelberman, R H; Chu, C R; Williams, C S; Seiler, J G; Amiel, D

    1992-09-01

    On the basis of recent evidence that flexor tendon grafts may heal without the ingrowth of vascular adhesions, eighteen autogenous donor tendons of intrasynovial and extrasynovial origin were transferred to the synovial sheaths in the forepaws of nine dogs, and controlled passive mobilization was instituted early in the postoperative period. The angiogenic responses of the tendon grafts were determined with perfusion studies with India ink followed by cleaing of the tissues with the Spalteholz technique at two, four, and six weeks. A consistent pattern of neovascularization was noted in the donor tendons of extrasynovial origin. Vascular adhesions arising from the flexor digitorum superficialis and the tendon sheath enveloped the tendon grafts by two weeks. By six weeks, the vascularity of the tendon grafts of extrasynovial origin appeared completely integrated with that of the surrounding tissues. Examination of cross sections revealed that the segments of tendon had been completely vascularized by obliquely oriented intratendinous vessels. In contrast, the flexor tendon grafts of intrasynovial origin healed without ingrowth of vascular adhesions. Primary intrinsic neovascularization took place from the proximal and, to a lesser extent, distal sites of the sutures. Examination of cross sections revealed vessels extending through the surface layer of the tendon graft, with small vessels penetrating the interior of the tendons at regular intervals.

  12. The effect of mechanical stimulation on the maturation of TDSCs-poly(L-lactide-co-e-caprolactone)/collagen scaffold constructs for tendon tissue engineering.

    PubMed

    Xu, Yuan; Dong, Shiwu; Zhou, Qiang; Mo, Xiumei; Song, Lei; Hou, Tianyong; Wu, Jinglei; Li, Songtao; Li, Yudong; Li, Pei; Gan, Yibo; Xu, Jianzhong

    2014-03-01

    Mechanical stimulation plays an important role in the development and remodeling of tendons. Tendon-derived stem cells (TDSCs) are an attractive cell source for tendon injury and tendon tissue engineering. However, these cells have not yet been fully explored for tendon tissue engineering application, and there is also lack of understanding to the effect of mechanical stimulation on the maturation of TDSCs-scaffold construct for tendon tissue engineering. In this study, we assessed the efficacy of TDSCs in a poly(L-lactide-co-ε-caprolactone)/collagen (P(LLA-CL)/Col) scaffold under mechanical stimulation for tendon tissue engineering both in vitro and in vivo, and evaluated the utility of the transplanted TDSCs-scaffold construct to promote rabbit patellar tendon defect regeneration. TDSCs displayed good proliferation and positive expressed tendon-related extracellular matrix (ECM) genes and proteins under mechanical stimulation in vitro. After implanting into the nude mice, the fluorescence imaging indicated that TDSCs had long-term survival, and the macroscopic evaluation, histology and immunohistochemistry examinations showed high-quality neo-tendon formation under mechanical stimulation in vivo. Furthermore, the histology, immunohistochemistry, collagen content assay and biomechanical testing data indicated that dynamically cultured TDSCs-scaffold construct could significantly contributed to tendon regeneration in a rabbit patellar tendon window defect model. TDSCs have significant potential to be used as seeded cells in the development of tissue-engineered tendons, which can be successfully fabricated through seeding of TDSCs in a P(LLA-CL)/Col scaffold followed by mechanical stimulation. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. The revitalisation of flexor tendon allografts with bone marrow stromal cells and mechanical stimulation: An ex vivo model revitalising flexor tendon allografts.

    PubMed

    Wu, J H; Thoreson, A R; Gingery, A; An, K N; Moran, S L; Amadio, P C; Zhao, C

    2017-03-01

    The present study describes a novel technique for revitalising allogenic intrasynovial tendons by combining cell-based therapy and mechanical stimulation in an ex vivo canine model. Specifically, canine flexor digitorum profundus tendons were used for this study and were divided into the following groups: (1) untreated, unprocessed normal tendon; (2) decellularised tendon; (3) bone marrow stromal cell (BMSC)-seeded tendon; and (4) BMSC-seeded and cyclically stretched tendon. Lateral slits were introduced on the tendon to facilitate cell seeding. Tendons from all four study groups were distracted by a servohydraulic testing machine. Tensile force and displacement data were continuously recorded at a sample rate of 20 Hz until 200 Newton of force was reached. Before testing, the cross-sectional dimensions of each tendon were measured with a digital caliper. Young's modulus was calculated from the slope of the linear region of the stress-strain curve. The BMSCs were labeled for histological and cell viability evaluation on the decellularized tendon scaffold under a confocal microscope. Gene expression levels of selected extracellular matrix tendon growth factor genes were measured. Results were reported as mean ± SD and data was analyzed with one-way ANOVAs followed by Tukey's post hoc multiple-comparison test. We observed no significant difference in cross-sectional area or in Young's modulus among the four study groups. In addition, histological sections showed that the BMSCs were aligned well and viable on the tendon slices after two-week culture in groups three and four. Expression levels of several extracellular matrix tendon growth factors, including collagen type I, collagen type III, and matrix metalloproteinase were significantly higher in group four than in group three (p < 0.05). Lateral slits introduced into de-cellularised tendon is a promising method of delivery of BMSCs without compromising cell viability and tendon mechanical properties. In addition, mechanical stimulation of a cell-seeded tendon can promote cell proliferation and enhance expression of collagen types I and III in vitro . Cite this article: J. H. Wu, A. R. Thoreson, A. Gingery, K. N. An, S. L. Moran, P. C. Amadio, C. Zhao. The revitalisation of flexor tendon allografts with bone marrow stromal cells and mechanical stimulation: An ex vivo model revitalising flexor tendon allografts. Bone Joint Res 2017;6:179-185. DOI: 10.1302/2046-3758.63.BJR-2016-0207.R1. © 2017 Zhao et al.

  14. Characteristics of Intratendinous Microcirculation Shortly After an Achilles Rupture and Subsequent Treatment Outcomes.

    PubMed

    Chang, Yi-Ping; Shih, Kao-Shang; Chiang, Hongsen; Ma, Hsiao-Li; Lin, Leou-Chyr; Peng, Wei-Chen; Wen, Che-Sheng; Wang, Hsing-Kuo

    2017-01-01

    Early microcirculatory responses after experimental tenotomy are critical to the healing of tendons and their ultimate tensile strength. The effects of changes in microcirculation on the outcomes of tendon healing, however, have not been determined. To assess microcirculation values in injured Achilles tendons in the first 3 months after surgical repair and to correlate the inter-limb microcirculatory changes with functional outcomes at 3 and 6 months after surgery. Case-control study. A university sports physiotherapy laboratory. Thirteen subjects (median age: 45 years; range: 34.8-51.9 years) with a repaired Achilles tendon were recruited. Surgical repair. Measurements were obtained at 1, 2, 3, and 6 months after surgery. Bilateral measurements of tendon microcirculation (total hemoglobin [THb] and oxygen saturation [StO 2 ]) were recorded at the first 3 time points, whereas outcome measures of a Taiwan Chinese version of the Victorian Institute of Sport Assessment Scale-Achilles questionnaire, one-leg hopping distance, the star excursion balance test, and the heel raise index were conducted at the third and fourth time points. Correlations between the inter-limb microcirculatory changes, eg, between the measurements at 2 months and 1 month (2-1) after surgery, at 3 months and 2 months (3-2) after surgery, and at 3 months and 1 month (3-1) after surgery, and the outcome measures were investigated. Compared with the noninjured tendons, the repaired Achilles demonstrated greater THb (at 1, 2, and 3 months; P = .017, .008, and .012 respectively) and StO 2 (at 3 months; P = .017). Furthermore, the THb2-1 and THb3-2, StO 2 2-1, and StO 2 3-2 showed correlations with the heel raise index, differences in the star excursion balance test and one-leg hopping distance between the noninjured leg and injured leg, and Taiwan Chinese version of the Victorian Institute of Sport Assessment Scale-Achilles questionnaire scores (rho -0.921 to 0.855). Changes in the inter-limb microcirculation shortly after Achilles repair were correlated with subsequent symptoms and functional symmetry. III. Copyright © 2017 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  15. Achilles Tendon Open Surgical Treatment With Platelet-Rich Fibrin Matrix Augmentation: Biomechanical Evaluation.

    PubMed

    Alviti, Federica; Gurzì, Michele; Santilli, Valter; Paoloni, Marco; Padua, Roberto; Bernetti, Andrea; Bernardi, Marco; Mangone, Massimiliano

    The relationship between surgical technique and ankle biomechanical properties after surgery for acute rupture of the Achilles tendon (ATR) has not yet been fully investigated. Platelet-rich fibrin (PRF) matrices seem to play a central role in the complex processes of tendon healing. Our aim was to analyze the biomechanical characteristics, stiffness, and mechanical work of the ankle during walking in patients who had undergone surgery after ATR with and without PRF augmentation. We performed a retrospective review of all consecutive patients who had been treated with surgical repair after ATR. Of the 20 male subjects enrolled, 9 (45%) had undergone conventional open repair of the Achilles tendon using the Krackow technique (no-PRF) and 11 (55%) had undergone surgery with PRF augmentation. An additional 8 healthy subjects were included as a control group. A gait analysis evaluation was performed at 6 months after surgery. The percentage of the stance time of the operated leg, double-support time of the healthy leg, and net work of the ankle during the gait cycle showed statistically significant differences between the no-PRF and the healthy group (p < .005). No differences were found between the PRF and healthy groups. Treatment with suture and PRF augmentation could result in significant functional improvements in term of efficiency of motion. Copyright © 2017 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  16. [The elbow joint - a diagnostic challenge : anatomy, biomechanics, and pathology].

    PubMed

    Schueller-Weidekamm, C; Kainberger, F

    2008-12-01

    The elbow is one of the most commonly injured joints in sports activities. In particular, weight lifters, golfers, tennis players, and pitchers are affected. Injuries in sports involving overhead throwing are commonly based on the pathophysiologic model of valgus extension overload syndrome. The injuries are commonly complex and demand a good knowledge of the symptoms, the exact anatomy, and the biomechanics to arrive at a precise radiologic diagnosis. The characteristic patterns of injury that occur in specific sports activities are related to a combination of increased varus or valgus and extension or flexion overload that results in tensile forces and/or compression and shear stress. Acute symptoms are frequently based on chronic degeneration of the tendons and ligamentous structures due to repetitive microtrauma from overuse syndrome.

  17. Nano/micro hybrid scaffold of PCL or P3HB nanofibers combined with silk fibroin for tendon and ligament tissue engineering.

    PubMed

    Naghashzargar, Elham; Farè, Silvia; Catto, Valentina; Bertoldi, Serena; Semnani, Dariush; Karbasi, Saeed; Tanzi, Maria Cristina

    2015-07-04

    A novel biodegradable nano/micro hybrid structure was obtained by electrospinning P3HB or PCL nanofibers onto a twisted silk fibroin (SF) structure, with the aim of fabricating a suitable scaffold for tendon and ligament tissue engineering. The electrospinning (ES) processing parameters for P3HB and PCL were optimized on 2D samples, and applied to produce two different nano/micro hybrid constructs (SF/ES-PCL and SF/ES-P3HB).Morphological, chemico-physical and mechanical properties of the novel hybrid scaffolds were evaluated by SEM, ATR FT-IR, DSC, tensile and thermodynamic mechanical tests. The results demonstrated that the nanofibers were tightly wrapped around the silk filaments, and the crystallinity of the SF twisted yarns was not influenced by the presence of the electrospun polymers. The slightly higher mechanical properties of the hybrid constructs confirmed an increase of internal forces due to the interaction between nano and micro components. Cell culture tests with L929 fibroblasts, in the presence of the sample eluates or in direct contact with the hybrid structures, showed no cytotoxic effects and a good level of cytocompatibility of the nano/micro hybrid structures in term of cell viability, particularly at day 1. Cell viability onto the nano/micro hybrid structures decreased from the first to the third day of culture when compared with the control culture plastic, but appeared to be higher when compared with the uncoated SF yarns. Although additional in vitro and in vivo tests are needed, the original fabrication method here described appears promising for scaffolds suitable for tendon and ligament tissue engineering.

  18. The Role of Mechanical Loading in Tendon Development, Maintenance, Injury, and Repair

    PubMed Central

    Galloway, Marc T.; Lalley, Andrea L.; Shearn, Jason T.

    2013-01-01

    ➤ Tendon injuries often result from excessive or insufficient mechanical loading, impairing the ability of the local tendon cell population to maintain normal tendon function. ➤ The resident cell population composing tendon tissue is mechanosensitive, given that the cells are able to alter the extracellular matrix in response to modifications of the local loading environment. ➤ Natural tendon healing is insufficient, characterized by improper collagen fibril diameter formation, collagen fibril distribution, and overall fibril misalignment. ➤ Current tendon repair rehabilitation protocols focus on implementing early, well-controlled eccentric loading exercises to improve repair outcome. ➤ Tissue engineers look toward incorporating mechanical loading regimens to precondition cell populations for the creation of improved biological augmentations for tendon repair. PMID:24005204

  19. Lipids, adiposity and tendinopathy: is there a mechanistic link? Critical review

    PubMed Central

    Scott, Alex; Zwerver, Johannes; Grewal, Navi; de Sa, Agnetha; Alktebi, Thuraya; Granville, David J; Hart, David A

    2015-01-01

    Being overweight or obese is associated with an elevated risk of tendon pathology. However, for sportspeople the epidemiological data linking weight or adiposity on one hand, and risk of tendon pathology on the other, are less consistent. Indeed, the mechanistic links between diet, adiposity and tendon pathology remain largely unexamined. Recent studies have begun to examine the effects of dietary interventions on outcomes such as tendon biomechanics or pain. Oxidised low-density lipoprotein has been shown to (A) accumulate in the tendon tissues of mice that eat a fatty diet and (B) induce a pathological phenotype in human tendon cells. This paper addresses the current debate: is excessive body mass index (causing increased load and strain on tendon tissue) per se the underlying mechanism? Or do local or systemic influences of fat on tendons predispose to tendon pathology? This narrative review argues that excessive blood lipids may be an important avenue for clinical investigations. PMID:25488953

  20. Robot Arm with Tendon Connector Plate and Linear Actuator

    NASA Technical Reports Server (NTRS)

    Bridgwater, Lyndon (Inventor); Millerman, Alexander (Inventor); Ihrke, Chris A. (Inventor); Diftler, Myron A. (Inventor); Nguyen, Vienny (Inventor)

    2014-01-01

    A robotic system includes a tendon-driven end effector, a linear actuator, a flexible tendon, and a plate assembly. The linear actuator assembly has a servo motor and a drive mechanism, the latter of which translates linearly with respect to a drive axis of the servo motor in response to output torque from the servo motor. The tendon connects to the end effector and drive mechanism. The plate assembly is disposed between the linear actuator assembly and the tendon-driven end effector and includes first and second plates. The first plate has a first side that defines a boss with a center opening. The second plate defines an accurate through-slot having tendon guide channels. The first plate defines a through passage for the tendon between the center opening and a second side of the first plate. A looped end of the flexible tendon is received within the tendon guide channels.

  1. Peroneal tendon pathology: Pre- and post-operative high resolution US and MR imaging.

    PubMed

    Kumar, Yogesh; Alian, Ali; Ahlawat, Shivani; Wukich, Dane K; Chhabra, Avneesh

    2017-07-01

    Peroneal tendon pathology is an important cause of lateral ankle pain and instability. Typical peroneal tendon disorders include tendinitis, tenosynovitis, partial and full thickness tendon tears, peroneal retinacular injuries, and tendon subluxations and dislocations. Surgery is usually indicated when conservative treatment fails. Familiarity with the peroneal tendon surgeries and expected postoperative imaging findings is essential for accurate assessment and to avoid diagnostic pitfalls. Cross-sectional imaging, especially ultrasound and MRI provide accurate pre-operative and post-operative evaluation of the peroneal tendon pathology. In this review article, the normal anatomy, clinical presentation, imaging features, pitfalls and commonly performed surgical treatments for peroneal tendon abnormalities will be reviewed. The role of dynamic ultrasound and kinematic MRI for the evaluation of peroneal tendons will be discussed. Normal and abnormal postsurgical imaging appearances will be illustrated. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Mechanisms of tendon injury and repair

    PubMed Central

    Thomopoulos, Stavros; Parks, William C.; Rifkin, Daniel B.; Derwin, Kathleen A.

    2015-01-01

    Tendon disorders are common and lead to significant disability, pain, healthcare cost, and lost productivity. A wide range of injury mechanisms exist leading to tendinopathy or tendon rupture. Tears can occur in healthy tendons that are acutely overloaded (e.g., during a high speed or high impact event) or lacerated (e.g., a knife injury). Tendinitis or tendinosis can occur in tendons exposed to overuse conditions (e.g., an elite swimmer’s training regimen) or intrinsic tissue degeneration (e.g., age-related degeneration). The healing potential of a torn or pathologic tendon varies depending on anatomic location (e.g., Achilles vs. rotator cuff) and local environment (e.g., intrasynovial vs. extrasynovial). Although healing occurs to varying degrees, in general healing of repaired tendons follows the typical wound healing course, including an early inflammatory phase, followed by proliferative and remodeling phases. Numerous treatment approaches have been attempted to improve tendon healing, including growth factor- and cell-based therapies and rehabilitation protocols. This review will describe the current state of knowledge of injury and repair of the three most common tendinopathies-- flexor tendon lacerations, Achilles tendon rupture, and rotator cuff disorders-- with a particular focus on the use of animal models for understanding tendon healing. PMID:25641114

  3. Peroneal tendon displacement accompanying intra-articular calcaneal fractures.

    PubMed

    Toussaint, Rull James; Lin, Darius; Ehrlichman, Lauren K; Ellington, J Kent; Strasser, Nicholas; Kwon, John Y

    2014-02-19

    Peroneal tendon displacement (subluxation or dislocation) accompanying an intra-articular calcaneal fracture is often undetected and under-treated. The goals of this study were to determine (1) the prevalence of peroneal tendon displacement accompanying intra-articular calcaneal fractures, (2) the association of tendon displacement with fracture classifications, (3) the association of tendon displacement with heel width, and (4) the rate of missed diagnosis of the tendon displacement on radiographs and computed tomography (CT) scans and the resulting treatment rate. A retrospective radiographic review of all calcaneal fractures presenting at three institutions from June 30, 2006, to June 30, 2011, was performed. CT imaging of 421 intra-articular calcaneal fractures involving the posterior facet was available for review. The prevalence of peroneal tendon displacement was noted and its associations with fracture classification and heel width were evaluated. Peroneal tendon displacement was identified in 118 (28.0%) of the 421 calcaneal fracture cases. The presence of tendon displacement was significantly associated with joint-depression fractures compared with tongue-type fractures (p < 0.001). Only twelve (10.2%) of the 118 cases of peroneal tendon displacement had been identified in the radiology reports. Although sixty-five (55.1%) of the fractures with tendon displacement had been treated with internal fixation, the tendon displacement was treated surgically in only seven (10.8%) of these cases. Analysis of CT images showed a 28% prevalence of peroneal tendon displacement accompanying intra-articular calcaneal fractures. Surgeons and radiologists are encouraged to consider this association.

  4. Continuous Shear Wave Elastography: a New Method to Measure in-vivo Viscoelastic Properties of Tendons

    PubMed Central

    Cortes, Daniel H.; Suydam, Stephen M.; Silbernagel, Karin Grävare; Buchanan, Thomas S.; Elliott, Dawn M.

    2015-01-01

    Viscoelastic mechanical properties are frequently altered after tendon injuries and during recovery. Therefore, non-invasive measurements of shear viscoelastic properties may help evaluate tendon recovery and compare the effectiveness of different therapies. The objectives of this study are to present an elastography method to measure localized viscoelastic properties of tendon and to present initial results in healthy and injured human Achilles and semitendinosus tendons. The technique used an external actuator to generate the shear waves in the tendon at different frequencies and plane wave imaging to measure shear wave displacements. For each of the excitation frequencies, maps of direction specific wave speeds were calculated using Local Frequency Estimation. Maps of viscoelastic properties were obtained using a pixel wise curve-fit of wave speed and frequency. The method was validated by comparing measurements of wave speed in agarose gels to those obtained using magnetic resonance elastography. Measurements in human healthy Achilles tendons revealed a pronounced increase in wave speed as function of frequency that highlights the importance of tendon viscoelasticity. Additionally, the viscoelastic properties of the Achilles tendon were larger than those reported for other tissues. Measurements in a tendinopathic Achilles tendon showed that it is feasible to quantify local viscoeasltic properties. Similarly, measurement in the semitendinosus tendon showed a substantial differences in viscoelastic properties between the healthy and contralateral tendons. Consequently, this technique has the potential of evaluating localized changes in tendon viscoelastic properties due to injury and during recovery in a clinical setting. PMID:25796414

  5. An Overview of the Management of Flexor Tendon Injuries

    PubMed Central

    Griffin, M; Hindocha, S; Jordan, D; Saleh, M; Khan, W

    2012-01-01

    Flexor tendon injuries still remain a challenging condition to manage to ensure optimal outcome for the patient. Since the first flexor tendon repair was described by Kirchmayr in 1917, several approaches to flexor tendon injury have enabled successful repairs rates of 70-90%. Primary surgical repair results in better functional outcome compared to secondary repair or tendon graft surgery. Flexor tendon injury repair has been extensively researched and the literature demonstrates successful repair requires minimal gapping at the repair site or interference with tendon vascularity, secure suture knots, smooth junction of tendon end and having sufficient strength for healing. However, the exact surgical approach to achieve success being currently used among surgeons is still controversial. Therefore, this review aims to discuss the results of studies demonstrating the current knowledge regarding the optimal approach for flexor tendon repair. Post-operative rehabilitation for flexor tendon surgery is another area, which has caused extensive debate in hand surgery. The trend to more active mobilisation protocols seems to be favoured but further study in this area is needed to find the protocol, which achieves function and gliding but avoids rupture of the tendons. Lastly despite success following surgery complications commonly still occur post surgery, including adhesion formation, tendon rupture and stiffness of the joints. Therefore, this review aims to discuss the appropriate management of these difficulties post surgery. New techniques in management of flexor tendon will also be discussed including external laser devices, addition of growth factors and cytokines. PMID:22431948

  6. Effect of Implanting a Soft Tissue Autograft in a Central-Third Patellar Tendon Defect: Biomechanical and Histological Comparisons

    PubMed Central

    Kinneberg, Kirsten R. C.; Galloway, Marc T.; Butler, David L.; Shearn, Jason T.

    2011-01-01

    Previous studies by our laboratory have demonstrated that implanting a stiffer tissue engineered construct at surgery is positively correlated with repair tissue stiffness at 12 weeks. The objective of this study was to test this correlation by implanting a construct that matches normal tissue biomechanical properties. To do this, we utilized a soft tissue patellar tendon autograft to repair a central-third patellar tendon defect. Patellar tendon auto-graft repairs were contrasted against an unfilled defect repaired by natural healing (NH). We hypothesized that after 12 weeks, patellar tendon autograft repairs would have biomechanical properties superior to NH. Bilateral defects were established in the central-third patellar tendon of skeletally mature (one year old), female New Zealand White rabbits (n = 10). In one limb, the excised tissue, the patellar tendon autograft, was sutured into the defect site. In the contralateral limb, the defect was left empty (natural healing). After 12 weeks of recovery, the animals were euthanized and their limbs were dedicated to bio-mechanical (n = 7) or histological (n = 3) evaluations. Only stiffness was improved by treatment with patellar tendon autograft relative to natural healing (p = 0.009). Additionally, neither the patellar tendon autograft nor natural healing repairs regenerated a normal zonal insertion site between the tendon and bone. Immunohistochemical staining for collagen type II demonstrated that fibrocartilage-like tissue was regenerated at the tendon-bone interface for both repairs. However, the tissue was disorganized. Insufficient tissue integration at the tendon-to-bone junction led to repair tissue failure at the insertion site during testing. It is important to re-establish the tendon-to-bone insertion site because it provides joint stability and enables force transmission from muscle to tendon and subsequent loading of the tendon. Without loading, tendon mechanical properties deteriorate. Future studies by our laboratory will investigate potential strategies to improve patellar tendon autograft integration into bone using this model. [DOI: 10.1115/1.4004948] PMID:22010737

  7. Arthroscopic Repair of Massive Cuff Tears With Large Subscapularis Tendon Ruptures (Lafosse III/IV): A Prospective Magnetic Resonance Imaging-Controlled Case Series of 26 Cases With a Minimum Follow-up of 1 Year.

    PubMed

    Grueninger, Patrick; Nikolic, Nikola; Schneider, Joerg; Lattmann, Thomas; Platz, Andreas; Chmiel, Corinne; Meier, Christoph

    2015-11-01

    To prospectively assess arthroscopic repair of massive cuff tears (MCT) in a highly selective patient group with large subscapularis (SSC) tendon tears by means of clinical results and magnetic resonance imaging (MRI) studies. Between April 2009 and December 2010, 26 patients with MCT were treated with arthroscopic rotator cuff repair. Only lesions involving a large tear of the SSC tendon (Lafosse III or IV) in combination with a complete tear of the supraspinatus (SSP) tendon and a tear of at least the anterior third of the infraspinatus (ISP) tendon were included. Minimum follow-up was 1 year. Pre- and postoperative assessment included a standardized clinical examination, subjective patient outcome, and MRI (structural integrity, fatty muscle infiltration, and muscular mass). Mean follow-up was 17 months (range, 12 to 34 months). MRI was performed in 25 patients. In 21 (84%) the cuff repair was intact. A partial retear of the SSC was found in 2 patients (8%). In 2 patients (8%) a full-thickness retear of the posterosuperior cuff was observed (1 SSP, 1 SSP/ISP). A significant increase of the muscle mass and decrease of fatty infiltration was observed for the SSC and SSP but not for the ISP. The mean Constant-Murley score improved from 36 to 86 points (P < .001) with all its subscores as well (P < .001). Muscular strength improved for the SSC (4.9 v 3.0, P < .001), SSP (4.6 v 2.9, P < .001), and ISP (4.8 v 3.4, P < .001). Overall patient satisfaction was high (3.6 ± 0.8). Arthroscopic repair of MCT involving the ISP, SSP, and large tears of the SSC provides a reliable tendon healing, in particular for the SSC tendon, combined with good functional results. Level IV, therapeutic case series. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  8. Characterization of calcium and zinc spatial distributions at the fibrocartilage zone of bone-tendon junction by synchrotron radiation-based micro X-ray fluorescence analysis combined with backscattered electron imaging

    NASA Astrophysics Data System (ADS)

    Lu, Hongbin; Chen, Can; Wang, Zhanwen; Qu, Jin; Xu, Daqi; Wu, Tianding; Cao, Yong; Zhou, Jingyong; Zheng, Cheng; Hu, Jianzhong

    2015-09-01

    Tendon attaches to bone through a functionally graded fibrocartilage zone, including uncalcified fibrocartilage (UF), tidemark (TM) and calcified fibrocartilage (CF). This transition zone plays a pivotal role in relaxing load transfer between tendon and bone, and serves as a boundary between otherwise structurally and functionally distinct tissue types. Calcium and zinc are believed to play important roles in the normal growth, mineralization, and repair of the fibrocartilage zone of bone-tendon junction (BTJ). However, spatial distributions of calcium and zinc at the fibrocartilage zone of BTJ and their distribution-function relationship are not totally understood. Thus, synchrotron radiation-based micro X-ray fluorescence analysis (SR-μXRF) in combination with backscattered electron imaging (BEI) was employed to characterize the distributions of calcium and zinc at the fibrocartilage zone of rabbit patella-patellar tendon complex (PPTC). For the first time, the unique distributions of calcium and zinc at the fibrocartilage zone of the PPTC were clearly mapped by this method. The distributions of calcium and zinc at the fibrocartilage zone of the PPTC were inhomogeneous. A significant accumulation of zinc was exhibited in the transition region between UF and CF. The highest zinc content (3.17 times of that of patellar tendon) was found in the TM of fibrocartilage zone. The calcium content began to increase near the TM and increased exponentially across the calcified fibrocartilage region towards the patella. The highest calcium content (43.14 times of that of patellar tendon) was in the transitional zone of calcified fibrocartilage region and the patella, approximately 69 μm from the location with the highest zinc content. This study indicated, for the first time, that there is a differential distribution of calcium and zinc at the fibrocartilage zone of PPTC. These observations reveal new insights into region-dependent changes across the fibrocartilage zone of BTJ and will serve as critical benchmark parameters for current efforts in BTJ repair.

  9. The promoting effect of pentadecapeptide BPC 157 on tendon healing involves tendon outgrowth, cell survival, and cell migration.

    PubMed

    Chang, Chung-Hsun; Tsai, Wen-Chung; Lin, Miao-Sui; Hsu, Ya-Hui; Pang, Jong-Hwei Su

    2011-03-01

    Pentadecapeptide BPC 157, composed of 15 amino acids, is a partial sequence of body protection compound (BPC) that is discovered in and isolated from human gastric juice. Experimentally it has been demonstrated to accelerate the healing of many different wounds, including transected rat Achilles tendon. This study was designed to investigate the potential mechanism of BPC 157 to enhance healing of injured tendon. The outgrowth of tendon fibroblasts from tendon explants cultured with or without BPC 157 was examined. Results showed that BPC 157 significantly accelerated the outgrowth of tendon explants. Cell proliferation of cultured tendon fibroblasts derived from rat Achilles tendon was not directly affected by BPC 157 as evaluated by MTT assay. However, the survival of BPC 157-treated cells was significantly increased under the H(2)O(2) stress. BPC 157 markedly increased the in vitro migration of tendon fibroblasts in a dose-dependent manner as revealed by transwell filter migration assay. BPC 157 also dose dependently accelerated the spreading of tendon fibroblasts on culture dishes. The F-actin formation as detected by FITC-phalloidin staining was induced in BPC 157-treated fibroblasts. The protein expression and activation of FAK and paxillin were determined by Western blot analysis, and the phosphorylation levels of both FAK and paxillin were dose dependently increased by BPC 157 while the total amounts of protein was unaltered. In conclusion, BPC 157 promotes the ex vivo outgrowth of tendon fibroblasts from tendon explants, cell survival under stress, and the in vitro migration of tendon fibroblasts, which is likely mediated by the activation of the FAK-paxillin pathway.

  10. Partial supraspinatus tears are associated with tendon lengthening.

    PubMed

    Farshad-Amacker, Nadja A; Buck, Florian M; Farshad, Mazda; Pfirrmann, Christian W A; Gerber, Christian

    2015-02-01

    Tendon tear may result in muscular retraction with the loss of contractile amplitude and strength of the rotator cuff muscles. Currently, neither a validated method of measuring supraspinatus tendon length nor normal values are known. It was therefore the purpose of this study to measure the normal length of the supraspinatus tendon and to determine whether partial tears are associated with changes in tendon length. MR examinations of 49 asymptomatic volunteers and 37 patients with arthroscopically proven, isolated partial tears of the supraspinatus tendon were compared. The ratio of the extramuscular tendon length to the distance between the footprint and the glenoid surface was calculated (TL/FG ratio). Tendon length measurements were taken by two independent readers at the bursal and articular surfaces at the anterior, the central and the posterior parts of the tendon. TL/FG ratios at the bursal surface of tendons with partial tears were significantly higher than those in the control group [anterior: 0.78 ± 0.20 vs. 0.66 ± 0.15 (p < 0.05); central: 0.61 ± 0.13 vs. 0.52 ± 0.10 (p < 0.05); posterior: 0.57 ± 0.15 vs. 0.52 ± 0.10 (p < 0.05)]. At the articular surface, differences were significant only anteriorly [0.60 ± 0.13, vs. 0.54 ± 0.10 (p < 0.05)]. A cut-off TL/FG ratio of 0.63 for measurements at the bursal surface in the center of the tendon achieved a sensitivity of 46 % and a specificity of 92 % for the identification of partial cuff tearing. A reproducible method for measurement of extramuscular supraspinatus tendon length is described. Partial tearing of the supraspinatus tendon is associated with significant tendon lengthening, suggesting failure in continuity, and this is most reliably measured on the bursal surface. III.

  11. Tendon Reattachment to Bone in an Ovine Tendon Defect Model of Retraction Using Allogenic and Xenogenic Demineralised Bone Matrix Incorporated with Mesenchymal Stem Cells.

    PubMed

    Thangarajah, Tanujan; Shahbazi, Shirin; Pendegrass, Catherine J; Lambert, Simon; Alexander, Susan; Blunn, Gordon W

    2016-01-01

    Tendon-bone healing following rotator cuff repairs is mainly impaired by poor tissue quality. Demineralised bone matrix promotes healing of the tendon-bone interface but its role in the treatment of tendon tears with retraction has not been investigated. We hypothesized that cortical demineralised bone matrix used with minimally manipulated mesenchymal stem cells will result in improved function and restoration of the tendon-bone interface with no difference between xenogenic and allogenic scaffolds. In an ovine model, the patellar tendon was detached from the tibial tuberosity and a complete distal tendon transverse defect measuring 1 cm was created. Suture anchors were used to reattach the tendon and xenogenic demineralised bone matrix + minimally manipulated mesenchymal stem cells (n = 5), or allogenic demineralised bone matrix + minimally manipulated mesenchymal stem cells (n = 5) were used to bridge the defect. Graft incorporation into the tendon and its effect on regeneration of the enthesis was assessed using histomorphometry. Force plate analysis was used to assess functional recovery. Compared to the xenograft, the allograft was associated with significantly higher functional weight bearing at 6 (P = 0.047), 9 (P = 0.028), and 12 weeks (P = 0.009). In the allogenic group this was accompanied by greater remodeling of the demineralised bone matrix into tendon-like tissue in the region of the defect (p = 0.015), and a more direct type of enthesis characterized by significantly more fibrocartilage (p = 0.039). No failures of tendon-bone healing were noted in either group. Demineralised bone matrix used with minimally manipulated mesenchymal stem cells promotes healing of the tendon-bone interface in an ovine model of acute tendon retraction, with superior mechanical and histological results associated with use of an allograft.

  12. Response of tibialis anterior tendon to a chronic exposure of stretch-shortening cycles: age effects

    PubMed Central

    Ensey, James S; Hollander, Melinda S; Wu, John Z; Kashon, Michael L; Baker, Brent B; Cutlip, Robert G

    2009-01-01

    Background The purpose of the current study was to investigate the effects of aging on tendon response to repetitive exposures of stretch-shortening cycles (SSC's). Methods The left hind limb from young (3 mo, N = 4) and old (30 mo, N = 9) male Fisher 344 × Brown Norway rats were exposed to 80 maximal SSCs (60 deg/s, 50 deg range of motion) 3x/week for 4.5 weeks in vivo. After the last exposure, tendons from the tibialis anterior muscle were isolated, stored at -80°C, and then tested using a micro-mechanical testing machine. Deformation of each tendon was evaluated using both relative grip-to-grip displacements and reference marks via a video system. Results At failure, the young control tendons had higher strain magnitude than the young exposed (p < 0.01) and the old control tendons (p < .0001). Total load at inflection was affected by age only (p < 0.01). Old exposed and control tendons exhibited significantly higher loads at the inflection point than their young counterparts (p < 0.05 for both comparisons). At failure, the old exposed tendons carried higher loads than the young exposed tendons (p < 0.05). Stiffness was affected by age only at failure where the old tendons exhibited higher stiffness in both exposed and control tendons than their young counterparts (p < 0.05 and p < 0.01, respectively). Conclusion The chronic protocol enhanced the elastic stiffness of young tendon and the loads in both the young and old tendons. The old exposed tendons were found to exhibit higher load capacity than their younger counterparts, which differed from our initial hypothesis. PMID:19563638

  13. The biomechanical effects of limb lengthening and botulinum toxin type A on rabbit tendon.

    PubMed

    Olabisi, Ronke M; Best, Thomas M; Hurschler, Christof; Vanderby, Ray; Noonan, Kenneth J

    2010-12-01

    Numerous studies have examined the effects of distraction osteogenesis (DO) on bone, but relatively fewer have explored muscle adaptation, and even less have addressed the concomitant alterations that occur in the tendon. The purpose herein was to characterize the biomechanical properties of normal and elongated rabbit (N = 20) tendons with and without prophylactic botulinum toxin type A (BTX-A) treatment. Elastic and viscoelastic properties of Achilles and Tibialis anterior (TA) tendons were evaluated through pull to failure and stress relaxation tests. All TA tendons displayed nonlinear viscoelastic responses that were strain dependent. A power law formulation was used to model tendon viscoelastic responses and tendon elastic responses were fit with a microstructural model. Distraction-elongated tendons displayed increases in compliance and stress relaxation rates over undistracted tendons; BTX-A administration offset this result. The elastic moduli of distraction-lengthened TA tendons were diminished (p = 0.010) when distraction was combined with gastrocnemius (GA) BTX-A administration, elastic moduli were further decreased (p = 0.004) and distraction following TA BTX-A administration resulted in TA tendons with moduli not different from contralateral control (p > 0.05). Compared to contralateral control, distraction and GA BTX-A administration displayed shortened toe regions, (p = 0.031 and 0.038, respectively), while tendons receiving BTX-A in the TA had no differences in the toe region (p > 0.05). Ultimate tensile stress was unaltered by DO, but stress at the transition from the toe to the linear region of the stress-stretch curve was diminished in all distraction-elongated TA tendons (p < 0.05). The data suggest that prophylactic BTX-A treatment to the TA protects some tendon biomechanical properties. Copyright © 2010 Elsevier Ltd. All rights reserved.

  14. The Quadriga Effect Revisited: Designing a “Safety Incision” to Prevent Tendon Repair Rupture and Gap Formation in a Canine Model In Vitro

    PubMed Central

    Giambini, Hugo; Ikeda, Jun; Amadio, Peter C.; An, Kai-Nan; Zhao, Chunfeng

    2012-01-01

    Loss of experimental animals due to tendon repair failure results in the need for additional animals to complete the study. We designed a relief proximal to the flexor digitorum profundus (FDP) tendon repair site to serve as a “safety incision” to prevent repair site ruptures and maximize safety incision-to-suture strength. The FDP tendons were dissected in 24 canine forepaws. The 2nd and 5th tendons were lacerated at the proximal interphalangeal joint level and sutured using a modified Kessler technique and peripheral running suture. Tendon width was measured where the FDP tendon separates into each individual digit and a safety incision, equal to the 2nd and 5th tendon widths, was performed 3, 4, or 5 mm (Groups 1, 2, and 3) proximal to the separation. The tendons were pulled at a rate of 1 mm/s until either the “safety incision” ruptured or the repair failed. There was no gap formation at the repair site in Groups 1 and 2. However, all Group 3 tendons failed by repair site rupture with the safety incision intact. An adequate safety incision to protect repair gap and rupture and maintain tendon tension for the FDP animal model should be about 4 mm from where the FDP tendon separates. PMID:20872585

  15. Biomechanical Cadaveric Evaluation of Partial Acute Peroneal Tendon Tears.

    PubMed

    Wagner, Emilio; Wagner, Pablo; Ortiz, Cristian; Radkievich, Ruben; Palma, Felipe; Guzmán-Venegas, Rodrigo

    2018-06-01

    No clear guideline or solid evidence exists for peroneal tendon tears to determine when to repair, resect, or perform a tenodesis on the damaged tendon. The objective of this study was to analyze the mechanical behavior of cadaveric peroneal tendons artificially damaged and tested in a cyclic and failure mode. The hypothesis was that no failure would be observed in the cyclic phase. Eight cadaveric long leg specimens were tested on a specially designed frame. A longitudinal full thickness tendon defect was created, 3 cm in length, behind the tip of the fibula, compromising 66% of the visible width of the peroneal tendons. Cyclic testing was initially performed between 50 and 200 N, followed by a load-to-failure test. Tendon elongation and load to rupture were measured. No tendon failed or lengthened during cyclic testing. The mean load to failure for peroneus brevis was 416 N (95% confidence interval, 351-481 N) and for the peroneus longus was 723 N (95% confidence interval, 578-868 N). All failures were at the level of the defect created. In a cadaveric model of peroneal tendon tears, 33% of remaining peroneal tendon could resist high tensile forces, above the physiologic threshold. Some peroneal tendon tears can be treated conservatively without risking spontaneous ruptures. When surgically treating a symptomatic peroneal tendon tear, increased efforts may be undertaken to repair tears previously considered irreparable.

  16. Greater glycosaminoglycan content in human patellar tendon biopsies is associated with more pain and a lower VISA score.

    PubMed

    Attia, Mohamed; Scott, Alexander; Carpentier, Gilles; Lian, Oystein; Van Kuppevelt, Toin; Gossard, Camille; Papy-Garcia, Dulce; Tassoni, Marie-Claude; Martelly, Isabelle

    2014-03-01

    People with patellar tendinopathy experience chronic pain and activity limitation, but a pertinent biochemical marker correlated with these clinical features has not been identified. The Victoria Institute of Sport Assessment (VISA) questionnaire is a condition-specific patient-rated outcome measure. Since the quantity of glycosaminoglycans (GAGs) increases with advancing tendon pathology, we hypothesised that there would be a correlation between the quantity of GAGs in the patellar tendon and the VISA score. Tissue biopsies from athletes with chronic patellar tendinopathy (confirmed by clinical examination and MRI) were recruited (n=7), as well as controls with no history of knee pain (n=4). The quantity of sulphated GAGs in the human patellar tendons was determined with a dimethyl methylene blue (DMMB) assay; this method was first validated with rat tendon tissue. The extent and distribution of GAG species and proteoglycans (decorin, versican and aggrecan) in the human tendon biopsies were examined using immunohistochemistry. Greater sulphated GAG content of the patellar tendon was correlated with the greater tendon dysfunction (R(2)=0.798). The quantity of aggrecan in the tendon, a chondroitin sulphate-rich proteoglycan, also increased with advancing tendon pathology. Increased GAGs in the pathological human patellar tendon are related to a worse clinical status. These findings indicate that the VISA score reflects the extent of tendon tissue pathology.

  17. Central Tendon Injuries of Hamstring Muscles: Case Series of Operative Treatment

    PubMed Central

    Lempainen, Lasse; Kosola, Jussi; Pruna, Ricard; Puigdellivol, Jordi; Sarimo, Janne; Niemi, Pekka; Orava, Sakari

    2018-01-01

    Background: As compared with injuries involving muscle only, those involving the central hamstring tendon have a worse prognosis. Limited information is available regarding the surgical treatment of central tendon injuries of the hamstrings. Purpose: To describe the operative treatment and outcomes of central tendon injuries of the hamstrings among athletes. Study Design: Case series; Level of evidence, 4. Methods: Eight athletes (6 top level, 2 recreational) with central hamstring tendon injuries underwent magnetic resonance imaging and surgical treatment. The indication for surgery was recurrent (n = 6) or acute (n = 2) central hamstring tendon injury. All patients followed the same postoperative rehabilitation protocol, and return to play was monitored. Results: Magnetic resonance imaging found a central tendon injury in all 3 hamstring muscles (long head of the biceps femoris, semimembranosus, and semitendinosus) with disrupted tendon ends. In acute and recurrent central tendon injuries, full return to play was achieved at 2.5 to 4 months. There were no adverse events during follow-up. Conclusion: Central tendon injuries of the hamstrings can be successfully repaired surgically after acute and recurrent ruptures. PMID:29479545

  18. Immunomodulatory effects of amniotic membrane matrix incorporated into collagen scaffolds.

    PubMed

    Hortensius, Rebecca A; Ebens, Jill H; Harley, Brendan A C

    2016-06-01

    Adult tendon wound repair is characterized by the formation of disorganized collagen matrix which leads to decreases in mechanical properties and scar formation. Studies have linked this scar formation to the inflammatory phase of wound healing. Instructive biomaterials designed for tendon regeneration are often designed to provide both structural and cellular support. In order to facilitate regeneration, success may be found by tempering the body's inflammatory response. This work combines collagen-glycosaminoglycan scaffolds, previously developed for tissue regeneration, with matrix materials (hyaluronic acid and amniotic membrane) that have been shown to promote healing and decreased scar formation in skin studies. The results presented show that scaffolds containing amniotic membrane matrix have significantly increased mechanical properties and that tendon cells within these scaffolds have increased metabolic activity even when the media is supplemented with the pro-inflammatory cytokine interleukin-1 beta. Collagen scaffolds containing hyaluronic acid or amniotic membrane also temper the expression of genes associated with the inflammatory response in normal tendon healing (TNF-α, COLI, MMP-3). These results suggest that alterations to scaffold composition, to include matrix known to decrease scar formation in vivo, can modify the inflammatory response in tenocytes. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 104A: 1332-1342, 2016. © 2016 Wiley Periodicals, Inc.

  19. Neuromuscular and muscle-tendon system adaptations to isotonic and isokinetic eccentric exercise.

    PubMed

    Guilhem, G; Cornu, C; Guével, A

    2010-06-01

    To present the properties of an eccentric contraction and compare neuromuscular and muscle-tendon system adaptations induced by isotonic and isokinetic eccentric trainings. An eccentric muscle contraction is characterized by the production of muscle force associated to a lengthening of the muscle-tendon system. This muscle solicitation can cause micro lesions followed by a regeneration process of the muscle-tendon system. Eccentric exercise is commonly used in functional rehabilitation for its positive effect on collagen synthesis but also for resistance training to increase muscle strength and muscle mass in athletes. Indeed, eccentric training stimulates muscle hypertrophy, increases the fascicle pennation angle, fascicles length and neural activation, thus inducing greater strength gains than concentric or isometric training programs. Eccentric exercise is commonly performed either against a constant external load (isotonic) or at constant velocity (isokinetic), inducing different mechanical constraints. These different mechanical constraints could induce structural and neural adaptive strategies specific to each type of exercise. The literature tends to show that isotonic mode leads to a greater strength gain than isokinetic mode. This observation could be explained by a greater neuromuscular activation after IT training. However, the specific muscle adaptations induced by each mode remain difficult to determine due to the lack of standardized, comparative studies. 2010 Elsevier Masson SAS. All rights reserved.

  20. Anatomic factors related to the cause of tennis elbow.

    PubMed

    Bunata, Robert E; Brown, David S; Capelo, Roderick

    2007-09-01

    The pathogenesis of lateral epicondylitis remains unclear. Our purpose was to study the anatomy of the lateral aspect of the elbow under static and dynamic conditions in order to identify bone-to-tendon and tendon-to-tendon contact or rubbing that might cause abrasion of the tissues. Eighty-five cadaveric elbows were examined to determine details related to the bone structure and musculotendinous origins. We identified the relative positions of the musculotendinous units and the underlying bone when the elbow was in different degrees of flexion. We also recorded the contact between the extensor carpi radialis brevis and the lateral edge of the capitellum as elbow motion occurred, and we sought to identify the areas of the capitellum and extensor carpi radialis brevis where contact occurs. The average site of origin of the extensor carpi radialis brevis on the humerus lay slightly medial and superior to the outer edge of the capitellum. As the elbow was extended, the undersurface of the extensor carpi radialis brevis rubbed against the lateral edge of the capitellum while the extensor carpi radialis longus compressed the brevis against the underlying bone. The extensor carpi radialis brevis tendon has a unique anatomic location that makes its undersurface vulnerable to contact and abrasion against the lateral edge of the capitellum during elbow motion.

Top