Sample records for test accuracy studies

  1. Preferred Reporting Items for a Systematic Review and Meta-analysis of Diagnostic Test Accuracy Studies: The PRISMA-DTA Statement.

    PubMed

    McInnes, Matthew D F; Moher, David; Thombs, Brett D; McGrath, Trevor A; Bossuyt, Patrick M; Clifford, Tammy; Cohen, Jérémie F; Deeks, Jonathan J; Gatsonis, Constantine; Hooft, Lotty; Hunt, Harriet A; Hyde, Christopher J; Korevaar, Daniël A; Leeflang, Mariska M G; Macaskill, Petra; Reitsma, Johannes B; Rodin, Rachel; Rutjes, Anne W S; Salameh, Jean-Paul; Stevens, Adrienne; Takwoingi, Yemisi; Tonelli, Marcello; Weeks, Laura; Whiting, Penny; Willis, Brian H

    2018-01-23

    Systematic reviews of diagnostic test accuracy synthesize data from primary diagnostic studies that have evaluated the accuracy of 1 or more index tests against a reference standard, provide estimates of test performance, allow comparisons of the accuracy of different tests, and facilitate the identification of sources of variability in test accuracy. To develop the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) diagnostic test accuracy guideline as a stand-alone extension of the PRISMA statement. Modifications to the PRISMA statement reflect the specific requirements for reporting of systematic reviews and meta-analyses of diagnostic test accuracy studies and the abstracts for these reviews. Established standards from the Enhancing the Quality and Transparency of Health Research (EQUATOR) Network were followed for the development of the guideline. The original PRISMA statement was used as a framework on which to modify and add items. A group of 24 multidisciplinary experts used a systematic review of articles on existing reporting guidelines and methods, a 3-round Delphi process, a consensus meeting, pilot testing, and iterative refinement to develop the PRISMA diagnostic test accuracy guideline. The final version of the PRISMA diagnostic test accuracy guideline checklist was approved by the group. The systematic review (produced 64 items) and the Delphi process (provided feedback on 7 proposed items; 1 item was later split into 2 items) identified 71 potentially relevant items for consideration. The Delphi process reduced these to 60 items that were discussed at the consensus meeting. Following the meeting, pilot testing and iterative feedback were used to generate the 27-item PRISMA diagnostic test accuracy checklist. To reflect specific or optimal contemporary systematic review methods for diagnostic test accuracy, 8 of the 27 original PRISMA items were left unchanged, 17 were modified, 2 were added, and 2 were omitted. The 27-item PRISMA diagnostic test accuracy checklist provides specific guidance for reporting of systematic reviews. The PRISMA diagnostic test accuracy guideline can facilitate the transparent reporting of reviews, and may assist in the evaluation of validity and applicability, enhance replicability of reviews, and make the results from systematic reviews of diagnostic test accuracy studies more useful.

  2. Systematic Review and Meta-Analysis of Studies Evaluating Diagnostic Test Accuracy: A Practical Review for Clinical Researchers-Part II. Statistical Methods of Meta-Analysis

    PubMed Central

    Lee, Juneyoung; Kim, Kyung Won; Choi, Sang Hyun; Huh, Jimi

    2015-01-01

    Meta-analysis of diagnostic test accuracy studies differs from the usual meta-analysis of therapeutic/interventional studies in that, it is required to simultaneously analyze a pair of two outcome measures such as sensitivity and specificity, instead of a single outcome. Since sensitivity and specificity are generally inversely correlated and could be affected by a threshold effect, more sophisticated statistical methods are required for the meta-analysis of diagnostic test accuracy. Hierarchical models including the bivariate model and the hierarchical summary receiver operating characteristic model are increasingly being accepted as standard methods for meta-analysis of diagnostic test accuracy studies. We provide a conceptual review of statistical methods currently used and recommended for meta-analysis of diagnostic test accuracy studies. This article could serve as a methodological reference for those who perform systematic review and meta-analysis of diagnostic test accuracy studies. PMID:26576107

  3. Accuracy of clinical tests in the diagnosis of anterior cruciate ligament injury: a systematic review

    PubMed Central

    2014-01-01

    Background Numerous clinical tests are used in the diagnosis of anterior cruciate ligament (ACL) injury but their accuracy is unclear. The purpose of this study is to evaluate the diagnostic accuracy of clinical tests for the diagnosis of ACL injury. Methods Study Design: Systematic review. The review protocol was registered through PROSPERO (CRD42012002069). Electronic databases (PubMed, MEDLINE, EMBASE, CINAHL) were searched up to 19th of June 2013 to identify diagnostic studies comparing the accuracy of clinical tests for ACL injury to an acceptable reference standard (arthroscopy, arthrotomy, or MRI). Risk of bias was appraised using the QUADAS-2 checklist. Index test accuracy was evaluated using a descriptive analysis of paired likelihood ratios and displayed as forest plots. Results A total of 285 full-text articles were assessed for eligibility, from which 14 studies were included in this review. Included studies were deemed to be clinically and statistically heterogeneous, so a meta-analysis was not performed. Nine clinical tests from the history (popping sound at time of injury, giving way, effusion, pain, ability to continue activity) and four from physical examination (anterior draw test, Lachman’s test, prone Lachman’s test and pivot shift test) were investigated for diagnostic accuracy. Inspection of positive and negative likelihood ratios indicated that none of the individual tests provide useful diagnostic information in a clinical setting. Most studies were at risk of bias and reported imprecise estimates of diagnostic accuracy. Conclusion Despite being widely used and accepted in clinical practice, the results of individual history items or physical tests do not meaningfully change the probability of ACL injury. In contrast combinations of tests have higher diagnostic accuracy; however the most accurate combination of clinical tests remains an area for future research. Clinical relevance Clinicians should be aware of the limitations associated with the use of clinical tests for diagnosis of ACL injury. PMID:25187877

  4. Empirical evidence of the importance of comparative studies of diagnostic test accuracy.

    PubMed

    Takwoingi, Yemisi; Leeflang, Mariska M G; Deeks, Jonathan J

    2013-04-02

    Systematic reviews that "compare" the accuracy of 2 or more tests often include different sets of studies for each test. To investigate the availability of direct comparative studies of test accuracy and to assess whether summary estimates of accuracy differ between meta-analyses of noncomparative and comparative studies. Systematic reviews in any language from the Database of Abstracts of Reviews of Effects and the Cochrane Database of Systematic Reviews from 1994 to October 2012. 1 of 2 assessors selected reviews that evaluated at least 2 tests and identified meta-analyses that included both noncomparative studies and comparative studies. 1 of 3 assessors extracted data about review and study characteristics and test performance. 248 reviews compared test accuracy; of the 6915 studies, 2113 (31%) were comparative. Thirty-six reviews (with 52 meta-analyses) had adequate studies to compare results of noncomparative and comparative studies by using a hierarchical summary receiver-operating characteristic meta-regression model for each test comparison. In 10 meta-analyses, noncomparative studies ranked tests in the opposite order of comparative studies. A total of 25 meta-analyses showed more than a 2-fold discrepancy in the relative diagnostic odds ratio between noncomparative and comparative studies. Differences in accuracy estimates between noncomparative and comparative studies were greater than expected by chance (P < 0.001). A paucity of comparative studies limited exploration of direction in bias. Evidence derived from noncomparative studies often differs from that derived from comparative studies. Robustly designed studies in which all patients receive all tests or are randomly assigned to receive one or other of the tests should be more routinely undertaken and are preferred for evidence to guide test selection. National Institute for Health Research (United Kingdom).

  5. Methods specification for diagnostic test accuracy studies in fine-needle aspiration cytology: a survey of reporting practice.

    PubMed

    Schmidt, Robert L; Factor, Rachel E; Affolter, Kajsa E; Cook, Joshua B; Hall, Brian J; Narra, Krishna K; Witt, Benjamin L; Wilson, Andrew R; Layfield, Lester J

    2012-01-01

    Diagnostic test accuracy (DTA) studies on fine-needle aspiration cytology (FNAC) often show considerable variability in diagnostic accuracy between study centers. Many factors affect the accuracy of FNAC. A complete description of the testing parameters would help make valid comparisons between studies and determine causes of performance variation. We investigated the manner in which test conditions are specified in FNAC DTA studies to determine which parameters are most commonly specified and the frequency with which they are specified and to see whether there is significant variability in reporting practice. We identified 17 frequently reported test parameters and found significant variation in the reporting of these test specifications across studies. On average, studies reported 5 of the 17 items that would be required to specify the test conditions completely. A more complete and standardized reporting of methods, perhaps by means of a checklist, would improve the interpretation of FNAC DTA studies.

  6. Test expectancy affects metacomprehension accuracy.

    PubMed

    Thiede, Keith W; Wiley, Jennifer; Griffin, Thomas D

    2011-06-01

    Theory suggests that the accuracy of metacognitive monitoring is affected by the cues used to judge learning. Researchers have improved monitoring accuracy by directing attention to more appropriate cues; however, this is the first study to more directly point students to more appropriate cues using instructions regarding tests and practice tests. The purpose of the present study was to examine whether the accuracy metacognitive monitoring was affected by the nature of the test expected. Students (N= 59) were randomly assigned to one of two test expectancy groups (memory vs. inference). Then after reading texts, judging learning, completed both memory and inference tests. Test performance and monitoring accuracy were superior when students received the kind of test they had been led to expect rather than the unexpected test. Tests influence students' perceptions of what constitutes learning. Our findings suggest that this could affect how students prepare for tests and how they monitoring their own learning. ©2010 The British Psychological Society.

  7. Receiver operating characteristic (ROC) curves: review of methods with applications in diagnostic medicine

    NASA Astrophysics Data System (ADS)

    Obuchowski, Nancy A.; Bullen, Jennifer A.

    2018-04-01

    Receiver operating characteristic (ROC) analysis is a tool used to describe the discrimination accuracy of a diagnostic test or prediction model. While sensitivity and specificity are the basic metrics of accuracy, they have many limitations when characterizing test accuracy, particularly when comparing the accuracies of competing tests. In this article we review the basic study design features of ROC studies, illustrate sample size calculations, present statistical methods for measuring and comparing accuracy, and highlight commonly used ROC software. We include descriptions of multi-reader ROC study design and analysis, address frequently seen problems of verification and location bias, discuss clustered data, and provide strategies for testing endpoints in ROC studies. The methods are illustrated with a study of transmission ultrasound for diagnosing breast lesions.

  8. Accuracy of clinical tests in the diagnosis of anterior cruciate ligament injury: a systematic review.

    PubMed

    Swain, Michael S; Henschke, Nicholas; Kamper, Steven J; Downie, Aron S; Koes, Bart W; Maher, Chris G

    2014-01-01

    Numerous clinical tests are used in the diagnosis of anterior cruciate ligament (ACL) injury but their accuracy is unclear. The purpose of this study is to evaluate the diagnostic accuracy of clinical tests for the diagnosis of ACL injury. Systematic review. The review protocol was registered through PROSPERO (CRD42012002069). Electronic databases (PubMed, MEDLINE, EMBASE, CINAHL) were searched up to 19th of June 2013 to identify diagnostic studies comparing the accuracy of clinical tests for ACL injury to an acceptable reference standard (arthroscopy, arthrotomy, or MRI). Risk of bias was appraised using the QUADAS-2 checklist. Index test accuracy was evaluated using a descriptive analysis of paired likelihood ratios and displayed as forest plots. A total of 285 full-text articles were assessed for eligibility, from which 14 studies were included in this review. Included studies were deemed to be clinically and statistically heterogeneous, so a meta-analysis was not performed. Nine clinical tests from the history (popping sound at time of injury, giving way, effusion, pain, ability to continue activity) and four from physical examination (anterior draw test, Lachman's test, prone Lachman's test and pivot shift test) were investigated for diagnostic accuracy. Inspection of positive and negative likelihood ratios indicated that none of the individual tests provide useful diagnostic information in a clinical setting. Most studies were at risk of bias and reported imprecise estimates of diagnostic accuracy. Despite being widely used and accepted in clinical practice, the results of individual history items or physical tests do not meaningfully change the probability of ACL injury. In contrast combinations of tests have higher diagnostic accuracy; however the most accurate combination of clinical tests remains an area for future research. Clinicians should be aware of the limitations associated with the use of clinical tests for diagnosis of ACL injury.

  9. Accuracy testing of electric groundwater-level measurement tapes

    USGS Publications Warehouse

    Jelinski, Jim; Clayton, Christopher S.; Fulford, Janice M.

    2015-01-01

    The accuracy tests demonstrated that none of the electric-tape models tested consistently met the suggested USGS accuracy of ±0.01 ft. The test data show that the tape models in the study should give a water-level measurement that is accurate to roughly ±0.05 ft per 100 ft without additional calibration. To meet USGS accuracy guidelines, the electric-tape models tested will need to be individually calibrated. Specific conductance also plays a part in tape accuracy. The probes will not work in water with specific conductance values near zero, and the accuracy of one probe was unreliable in very high conductivity water (10,000 microsiemens per centimeter).

  10. Using Meta-Analysis to Inform the Design of Subsequent Studies of Diagnostic Test Accuracy

    ERIC Educational Resources Information Center

    Hinchliffe, Sally R.; Crowther, Michael J.; Phillips, Robert S.; Sutton, Alex J.

    2013-01-01

    An individual diagnostic accuracy study rarely provides enough information to make conclusive recommendations about the accuracy of a diagnostic test; particularly when the study is small. Meta-analysis methods provide a way of combining information from multiple studies, reducing uncertainty in the result and hopefully providing substantial…

  11. Protocol for accuracy of point of care (POC) or in-office urine drug testing (immunoassay) in chronic pain patients: a prospective analysis of immunoassay and liquid chromatography tandem mass spectometry (LC/MS/MS).

    PubMed

    Manchikanti, Laxmaiah; Malla, Yogesh; Wargo, Bradley W; Cash, Kimberly A; Pampati, Vidyasagar; Damron, Kim S; McManus, Carla D; Brandon, Doris E

    2010-01-01

    Therapeutic use, overuse, abuse, and diversion of controlled substances in managing chronic non-cancer pain continues to be an issue for physicians and patients. It has been stated that physicians, along with the public and federal, state, and local government; professional associations; and pharmaceutical companies all share responsibility for preventing abuse of controlled prescription drugs. The challenge is to eliminate or significantly curtail abuse of controlled prescription drugs while still assuring the proper treatment of those patients. A number of techniques, instruments, and tools have been described to monitor controlled substance use and abuse. Thus, multiple techniques and tools available for adherence monitoring include urine drug testing in conjunction with prescription monitoring programs and other screening tests. However, urine drug testing is associated with multiple methodological flaws. Multiple authors have provided conflicting results in relation to diagnostic accuracy with differing opinions about how to monitor adherence in a non-systematic fashion. Thus far, there have not been any studies systematically assessing the diagnostic accuracy of immunoassay with laboratory testing. A diagnostic accuracy study of urine drug testing. An interventional pain management practice, a specialty referral center, a private practice setting in the United States. To compare the information obtained by point of care (POC) or in-office urine drug testing (index test) to the information found when all drugs and analytes are tested by liquid chromatography tandem mass spectroscopy (LC/MS/MS) reference test in the same urine sample. The study is designed to include 1,000 patients with chronic pain receiving controlled substances. The primary outcome measure is the diagnostic accuracy. Patients will be tested for various controlled substances, including opioids, benzodiazepines, and illicit drugs. The diagnostic accuracy study is performed utilizing the Standards for Reporting of Diagnostic Accuracy Studies (STARD) initiative which established reporting guidelines for diagnostic accuracy studies to improve the quality of reporting. The prototypical flow diagram of diagnostic accuracy study as described by STARD will be utilized. Results of diagnostic accuracy and correlation of clinical factors in relation to threshold levels, prevalence of abuse, false-positives, false-negatives, influence of other drugs, and demographic characteristics will be calculated. The limitations include lack of availability of POC testing with lower cutoff levels. This article presents a protocol for a diagnostic accuracy study of urine drug testing. The protocol also will permit correlation of various clinical factors in relation to threshold levels, prevalence of abuse, false-positives, false-negatives, influence of other drugs, and demographic characteristics. NCT 01052155.

  12. Age-related reduction of the confidence-accuracy relationship in episodic memory: effects of recollection quality and retrieval monitoring.

    PubMed

    Wong, Jessica T; Cramer, Stefanie J; Gallo, David A

    2012-12-01

    We investigated age-related reductions in episodic metamemory accuracy. Participants studied pictures and words in different colors and then took forced-choice recollection tests. These tests required recollection of the earlier presentation color, holding familiarity of the response options constant. Metamemory accuracy was assessed for each participant by comparing recollection test accuracy with corresponding confidence judgments. We found that recollection test accuracy was greater in younger than older adults and also for pictures than font color. Metamemory accuracy tracked each of these recollection differences, as well as individual differences in recollection test accuracy within each age group, suggesting that recollection ability affects metamemory accuracy. Critically, the age-related impairment in metamemory accuracy persisted even when the groups were matched on recollection test accuracy, suggesting that metamemory declines were not entirely due to differences in recollection frequency or quantity, but that differences in recollection quality and/or monitoring also played a role. We also found that age-related impairments in recollection and metamemory accuracy were equivalent for pictures and font colors. This result contrasted with previous false recognition findings, which predicted that older adults would be differentially impaired when monitoring memory for less distinctive memories. These and other results suggest that age-related reductions in metamemory accuracy are not entirely attributable to false recognition effects, but also depend heavily on deficient recollection and/or monitoring of specific details associated with studied stimuli. 2013 APA, all rights reserved

  13. Bias in estimating accuracy of a binary screening test with differential disease verification

    PubMed Central

    Brinton, John T.; Ringham, Brandy M.; Glueck, Deborah H.

    2011-01-01

    SUMMARY Sensitivity, specificity, positive and negative predictive value are typically used to quantify the accuracy of a binary screening test. In some studies it may not be ethical or feasible to obtain definitive disease ascertainment for all subjects using a gold standard test. When a gold standard test cannot be used an imperfect reference test that is less than 100% sensitive and specific may be used instead. In breast cancer screening, for example, follow-up for cancer diagnosis is used as an imperfect reference test for women where it is not possible to obtain gold standard results. This incomplete ascertainment of true disease, or differential disease verification, can result in biased estimates of accuracy. In this paper, we derive the apparent accuracy values for studies subject to differential verification. We determine how the bias is affected by the accuracy of the imperfect reference test, the percent who receive the imperfect reference standard test not receiving the gold standard, the prevalence of the disease, and the correlation between the results for the screening test and the imperfect reference test. It is shown that designs with differential disease verification can yield biased estimates of accuracy. Estimates of sensitivity in cancer screening trials may be substantially biased. However, careful design decisions, including selection of the imperfect reference test, can help to minimize bias. A hypothetical breast cancer screening study is used to illustrate the problem. PMID:21495059

  14. Pigeons exhibit higher accuracy for chosen memory tests than for forced memory tests in duration matching-to-sample.

    PubMed

    Adams, Allison; Santi, Angelo

    2011-03-01

    Following training to match 2- and 8-sec durations of feederlight to red and green comparisons with a 0-sec baseline delay, pigeons were allowed to choose to take a memory test or to escape the memory test. The effects of sample omission, increases in retention interval, and variation in trial spacing on selection of the escape option and accuracy were studied. During initial testing, escaping the test did not increase as the task became more difficult, and there was no difference in accuracy between chosen and forced memory tests. However, with extended training, accuracy for chosen tests was significantly greater than for forced tests. In addition, two pigeons exhibited higher accuracy on chosen tests than on forced tests at the short retention interval and greater escape rates at the long retention interval. These results have not been obtained in previous studies with pigeons when the choice to take the test or to escape the test is given before test stimuli are presented. It appears that task-specific methodological factors may determine whether a particular species will exhibit the two behavioral effects that were initially proposed as potentially indicative of metacognition.

  15. A New, Wireless-enabled Blood Glucose Monitoring System That Links to a Smart Mobile Device: Accuracy and User Performance Evaluation.

    PubMed

    Christiansen, Mark; Greene, Carmine; Pardo, Scott; Warchal-Windham, Mary Ellen; Harrison, Bern; Morin, Robert; Bailey, Timothy S

    2017-05-01

    These studies investigated the accuracy of the new Contour ® Next ONE blood glucose monitoring system (BGMS) that is designed to sync with the Contour™ Diabetes app on a smartphone or tablet. A laboratory study tested fingertip capillary blood samples from 100 subjects in duplicate using 3 test strip lots, based on ISO 15197:2013 Section 6.3 analytical accuracy standards. A clinical study assessed accuracy per ISO 15197:2013 Section 8 criteria. Subjects with (n = 333) or without (n = 43) diabetes and who had not used the BGMS previously were enrolled. Each subject performed a self-test using the BGMS, which was repeated by a site staff member. Alternate site tests and venipunctures were also performed for analysis. A questionnaire was provided to assess user feedback on ease of use. In the laboratory study, 100% (600/600) of combined results for all 3 test strip lots met ISO 15197:2013 Section 6.3 accuracy criteria. In the clinical study, among subjects with diabetes, 99.4% (327/329) of subject self-test results, 99.7% (331/332) of results obtained by study staff, 97.2% (309/318) of subject palm results, and 100% (330/330) of venous results met ISO 15197:2013 Section 8 accuracy criteria. Moreover, 97.6% (321/329) of subject self-test results were within ±10 mg/dl (±0.6 mmol/L) or ±10% of the YSI reference result. Questionnaire results indicated that most subjects considered the system easy to use. The BGMS exceeded ISO 15197:2013 accuracy criteria in the laboratory and in a clinical setting.

  16. Quality and reporting of diagnostic accuracy studies in TB, HIV and malaria: evaluation using QUADAS and STARD standards.

    PubMed

    Fontela, Patricia Scolari; Pant Pai, Nitika; Schiller, Ian; Dendukuri, Nandini; Ramsay, Andrew; Pai, Madhukar

    2009-11-13

    Poor methodological quality and reporting are known concerns with diagnostic accuracy studies. In 2003, the QUADAS tool and the STARD standards were published for evaluating the quality and improving the reporting of diagnostic studies, respectively. However, it is unclear whether these tools have been applied to diagnostic studies of infectious diseases. We performed a systematic review on the methodological and reporting quality of diagnostic studies in TB, malaria and HIV. We identified diagnostic accuracy studies of commercial tests for TB, malaria and HIV through a systematic search of the literature using PubMed and EMBASE (2004-2006). Original studies that reported sensitivity and specificity data were included. Two reviewers independently extracted data on study characteristics and diagnostic accuracy, and used QUADAS and STARD to evaluate the quality of methods and reporting, respectively. Ninety (38%) of 238 articles met inclusion criteria. All studies had design deficiencies. Study quality indicators that were met in less than 25% of the studies included adequate description of withdrawals (6%) and reference test execution (10%), absence of index test review bias (19%) and reference test review bias (24%), and report of uninterpretable results (22%). In terms of quality of reporting, 9 STARD indicators were reported in less than 25% of the studies: methods for calculation and estimates of reproducibility (0%), adverse effects of the diagnostic tests (1%), estimates of diagnostic accuracy between subgroups (10%), distribution of severity of disease/other diagnoses (11%), number of eligible patients who did not participate in the study (14%), blinding of the test readers (16%), and description of the team executing the test and management of indeterminate/outlier results (both 17%). The use of STARD was not explicitly mentioned in any study. Only 22% of 46 journals that published the studies included in this review required authors to use STARD. Recently published diagnostic accuracy studies on commercial tests for TB, malaria and HIV have moderate to low quality and are poorly reported. The more frequent use of tools such as QUADAS and STARD may be necessary to improve the methodological and reporting quality of future diagnostic accuracy studies in infectious diseases.

  17. Quality and Reporting of Diagnostic Accuracy Studies in TB, HIV and Malaria: Evaluation Using QUADAS and STARD Standards

    PubMed Central

    Fontela, Patricia Scolari; Pant Pai, Nitika; Schiller, Ian; Dendukuri, Nandini; Ramsay, Andrew; Pai, Madhukar

    2009-01-01

    Background Poor methodological quality and reporting are known concerns with diagnostic accuracy studies. In 2003, the QUADAS tool and the STARD standards were published for evaluating the quality and improving the reporting of diagnostic studies, respectively. However, it is unclear whether these tools have been applied to diagnostic studies of infectious diseases. We performed a systematic review on the methodological and reporting quality of diagnostic studies in TB, malaria and HIV. Methods We identified diagnostic accuracy studies of commercial tests for TB, malaria and HIV through a systematic search of the literature using PubMed and EMBASE (2004–2006). Original studies that reported sensitivity and specificity data were included. Two reviewers independently extracted data on study characteristics and diagnostic accuracy, and used QUADAS and STARD to evaluate the quality of methods and reporting, respectively. Findings Ninety (38%) of 238 articles met inclusion criteria. All studies had design deficiencies. Study quality indicators that were met in less than 25% of the studies included adequate description of withdrawals (6%) and reference test execution (10%), absence of index test review bias (19%) and reference test review bias (24%), and report of uninterpretable results (22%). In terms of quality of reporting, 9 STARD indicators were reported in less than 25% of the studies: methods for calculation and estimates of reproducibility (0%), adverse effects of the diagnostic tests (1%), estimates of diagnostic accuracy between subgroups (10%), distribution of severity of disease/other diagnoses (11%), number of eligible patients who did not participate in the study (14%), blinding of the test readers (16%), and description of the team executing the test and management of indeterminate/outlier results (both 17%). The use of STARD was not explicitly mentioned in any study. Only 22% of 46 journals that published the studies included in this review required authors to use STARD. Conclusion Recently published diagnostic accuracy studies on commercial tests for TB, malaria and HIV have moderate to low quality and are poorly reported. The more frequent use of tools such as QUADAS and STARD may be necessary to improve the methodological and reporting quality of future diagnostic accuracy studies in infectious diseases. PMID:19915664

  18. Diagnostic Accuracy of the Neck Tornado Test as a New Screening Test in Cervical Radiculopathy.

    PubMed

    Park, Juyeon; Park, Woo Young; Hong, Seungbae; An, Jiwon; Koh, Jae Chul; Lee, Youn-Woo; Kim, Yong Chan; Choi, Jong Bum

    2017-01-01

    The Spurling test, although a highly specific provocative test of the cervical spine in cervical radiculopathy (CR), has low to moderate sensitivity. Thus, we introduced the neck tornado test (NTT) to examine the neck and the cervical spine in CR. The aim of this study was to introduce a new provocative test, the NTT, and compare the diagnostic accuracy with a widely accepted provocative test, the Spurling test. Retrospective study. Medical records of 135 subjects with neck pain (CR, n = 67; without CR, n = 68) who had undergone cervical spine magnetic resonance imaging and been referred to the pain clinic between September 2014 and August 2015 were reviewed. Both the Spurling test and NTT were performed in all patients by expert examiners. Sensitivity, specificity, and accuracy were compared for both the Spurling test and the NTT. The sensitivity of the Spurling test and the NTT was 55.22% and 85.07% ( P < 0.0001); specificity, 98.53% and 86.76% ( P = 0.0026); accuracy, 77.04% and 85.93% ( P = 0.0423), respectively. The NTT is more sensitive with superior diagnostic accuracy for CR diagnosed by magnetic resonance imaging than the Spurling test.

  19. Physical examination tests for screening and diagnosis of cervicogenic headache: A systematic review.

    PubMed

    Rubio-Ochoa, J; Benítez-Martínez, J; Lluch, E; Santacruz-Zaragozá, S; Gómez-Contreras, P; Cook, C E

    2016-02-01

    It has been suggested that differential diagnosis of headaches should consist of a robust subjective examination and a detailed physical examination of the cervical spine. Cervicogenic headache (CGH) is a form of headache that involves referred pain from the neck. To our knowledge, no studies have summarized the reliability and diagnostic accuracy of physical examination tests for CGH. The aim of this study was to summarize the reliability and diagnostic accuracy of physical examination tests used to diagnose CGH. A systematic review following PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines was performed in four electronic databases (MEDLINE, Web of Science, Embase and Scopus). Full text reports concerning physical tests for the diagnosis of CGH which reported the clinometric properties for assessment of CGH, were included and screened for methodological quality. Quality Appraisal for Reliability Studies (QAREL) and Quality Assessment of Studies of Diagnostic Accuracy (QUADAS-2) scores were completed to assess article quality. Eight articles were retrieved for quality assessment and data extraction. Studies investigating diagnostic reliability of physical examination tests for CGH scored poorer on methodological quality (higher risk of bias) than those of diagnostic accuracy. There is sufficient evidence showing high levels of reliability and diagnostic accuracy of the selected physical examination tests for the diagnosis of CGH. The cervical flexion-rotation test (CFRT) exhibited both the highest reliability and the strongest diagnostic accuracy for the diagnosis of CGH. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Accuracy of Carbohydrate Counting in Adults

    PubMed Central

    Rushton, Wanda E.

    2016-01-01

    In Brief This study investigates carbohydrate counting accuracy in patients using insulin through a multiple daily injection regimen or continuous subcutaneous insulin infusion. The average accuracy test score for all patients was 59%. The carbohydrate test in this study can be used to emphasize the importance of carbohydrate counting to patients and to provide ongoing education. PMID:27621531

  1. Text Difficulty Affects Metacomprehension Accuracy and Knowledge Test Performance in Text Learning

    ERIC Educational Resources Information Center

    Vössing, J.; Stamov-Roßnagel, C.; Heinitz, K.

    2017-01-01

    Metacomprehension as reflected in judgements of one's learning is crucial for self-regulated study, yet their accuracy is often low. We investigated text difficulty as a constraint on metacomprehension accuracy in text learning. A total of 235 participants studied a 10-section expository text and afterwards took a knowledge test. They made…

  2. Accuracy of a Rapid Diagnostic Test (Cypress Chagas Quick Test®) for the Diagnosis of Chronic Chagas Disease in a Nonendemic Area: A Retrospective Longitudinal Study.

    PubMed

    Angheben, Andrea; Staffolani, Silvia; Anselmi, Mariella; Tais, Stefano; Degani, Monica; Gobbi, Federico; Buonfrate, Dora; Gobbo, Maria; Bisoffi, Zeno

    2017-11-01

    We analyzed the accuracy of Chagas Quick Test ® , a rapid diagnostic test, for the diagnosis of chronic Chagas disease through a retrospective study on a cohort of 669 patients consecutively examined at a single reference center in Italy, during a 7-year period. We observed high concordance with serological reference standard but low accuracy for screening purposes (sensitivity/specificity: 82.8%/98.7%) at least in our nonendemic context.

  3. Diagnostic Accuracy of Molecular Amplification Tests for Human African Trypanosomiasis—Systematic Review

    PubMed Central

    Boer, Kimberly R.; Dyserinck, Heleen C.; Büscher, Philippe; Schallig, Henk D. H. F.; Leeflang, Mariska M. G.

    2012-01-01

    Background A range of molecular amplification techniques have been developed for the diagnosis of Human African Trypanosomiasis (HAT); however, careful evaluation of these tests must precede implementation to ensure their high clinical accuracy. Here, we investigated the diagnostic accuracy of molecular amplification tests for HAT, the quality of articles and reasons for variation in accuracy. Methodology Data from studies assessing diagnostic molecular amplification tests were extracted and pooled to calculate accuracy. Articles were included if they reported sensitivity and specificity or data whereby values could be calculated. Study quality was assessed using QUADAS and selected studies were analysed using the bivariate random effects model. Results 16 articles evaluating molecular amplification tests fulfilled the inclusion criteria: PCR (n = 12), NASBA (n = 2), LAMP (n = 1) and a study comparing PCR and NASBA (n = 1). Fourteen articles, including 19 different studies were included in the meta-analysis. Summary sensitivity for PCR on blood was 99.0% (95% CI 92.8 to 99.9) and the specificity was 97.7% (95% CI 93.0 to 99.3). Differences in study design and readout method did not significantly change estimates although use of satellite DNA as a target significantly lowers specificity. Sensitivity and specificity of PCR on CSF for staging varied from 87.6% to 100%, and 55.6% to 82.9% respectively. Conclusion Here, PCR seems to have sufficient accuracy to replace microscopy where facilities allow, although this conclusion is based on multiple reference standards and a patient population that was not always representative. Future studies should, therefore, include patients for which PCR may become the test of choice and consider well designed diagnostic accuracy studies to provide extra evidence on the value of PCR in practice. Another use of PCR for control of disease could be to screen samples collected from rural areas and test in reference laboratories, to spot epidemics quickly and direct resources appropriately. PMID:22253934

  4. Diagnostic accuracy of molecular amplification tests for human African trypanosomiasis--systematic review.

    PubMed

    Mugasa, Claire M; Adams, Emily R; Boer, Kimberly R; Dyserinck, Heleen C; Büscher, Philippe; Schallig, Henk D H F; Leeflang, Mariska M G

    2012-01-01

    A range of molecular amplification techniques have been developed for the diagnosis of Human African Trypanosomiasis (HAT); however, careful evaluation of these tests must precede implementation to ensure their high clinical accuracy. Here, we investigated the diagnostic accuracy of molecular amplification tests for HAT, the quality of articles and reasons for variation in accuracy. Data from studies assessing diagnostic molecular amplification tests were extracted and pooled to calculate accuracy. Articles were included if they reported sensitivity and specificity or data whereby values could be calculated. Study quality was assessed using QUADAS and selected studies were analysed using the bivariate random effects model. 16 articles evaluating molecular amplification tests fulfilled the inclusion criteria: PCR (n = 12), NASBA (n = 2), LAMP (n = 1) and a study comparing PCR and NASBA (n = 1). Fourteen articles, including 19 different studies were included in the meta-analysis. Summary sensitivity for PCR on blood was 99.0% (95% CI 92.8 to 99.9) and the specificity was 97.7% (95% CI 93.0 to 99.3). Differences in study design and readout method did not significantly change estimates although use of satellite DNA as a target significantly lowers specificity. Sensitivity and specificity of PCR on CSF for staging varied from 87.6% to 100%, and 55.6% to 82.9% respectively. Here, PCR seems to have sufficient accuracy to replace microscopy where facilities allow, although this conclusion is based on multiple reference standards and a patient population that was not always representative. Future studies should, therefore, include patients for which PCR may become the test of choice and consider well designed diagnostic accuracy studies to provide extra evidence on the value of PCR in practice. Another use of PCR for control of disease could be to screen samples collected from rural areas and test in reference laboratories, to spot epidemics quickly and direct resources appropriately.

  5. Skin Testing for Allergic Rhinitis: A Health Technology Assessment

    PubMed Central

    Kabali, Conrad; Chan, Brian; Higgins, Caroline; Holubowich, Corinne

    2016-01-01

    Background Allergic rhinitis is the most common type of allergy worldwide. The accuracy of skin testing for allergic rhinitis is still debated. This health technology assessment had two objectives: to determine the diagnostic accuracy of skin-prick and intradermal testing in patients with suspected allergic rhinitis and to estimate the costs to the Ontario health system of skin testing for allergic rhinitis. Methods We searched All Ovid MEDLINE, Embase, and Cochrane Database of Systematic Reviews, Database of Abstracts of Reviews of Effects, CRD Health Technology Assessment Database, Cochrane Central Register of Controlled Trials, and NHS Economic Evaluation Database for studies that evaluated the diagnostic accuracy of skin-prick and intradermal testing for allergic rhinitis using nasal provocation as the reference standard. For the clinical evidence review, data extraction and quality assessment were performed using the QUADAS-2 tool. We used the bivariate random-effects model for meta-analysis. For the economic evidence review, we assessed studies using a modified checklist developed by the (United Kingdom) National Institute for Health and Care Excellence. We estimated the annual cost of skin testing for allergic rhinitis in Ontario for 2015 to 2017 using provincial data on testing volumes and costs. Results We meta-analyzed seven studies with a total of 430 patients that assessed the accuracy of skin-prick testing. The pooled pair of sensitivity and specificity for skin-prick testing was 85% and 77%, respectively. We did not perform a meta-analysis for the diagnostic accuracy of intradermal testing due to the small number of studies (n = 4). Of these, two evaluated the accuracy of intradermal testing in confirming negative skin-prick testing results, with sensitivity ranging from 27% to 50% and specificity ranging from 60% to 100%. The other two studies evaluated the accuracy of intradermal testing as a stand-alone tool for diagnosing allergic rhinitis, with sensitivity ranging from 60% to 79% and specificity ranging from 68% to 69%. We estimated the budget impact of continuing to publicly fund skin testing for allergic rhinitis in Ontario to be between $2.5 million and $3.0 million per year. Conclusions Skin-prick testing is moderately accurate in identifying subjects with or without allergic rhinitis. The diagnostic accuracy of intradermal testing could not be well established from this review. Our best estimate is that publicly funding skin testing for allergic rhinitis costs the Ontario government approximately $2.5 million to $3.0 million per year. PMID:27279928

  6. Skin Testing for Allergic Rhinitis: A Health Technology Assessment.

    PubMed

    2016-01-01

    Allergic rhinitis is the most common type of allergy worldwide. The accuracy of skin testing for allergic rhinitis is still debated. This health technology assessment had two objectives: to determine the diagnostic accuracy of skin-prick and intradermal testing in patients with suspected allergic rhinitis and to estimate the costs to the Ontario health system of skin testing for allergic rhinitis. We searched All Ovid MEDLINE, Embase, and Cochrane Database of Systematic Reviews, Database of Abstracts of Reviews of Effects, CRD Health Technology Assessment Database, Cochrane Central Register of Controlled Trials, and NHS Economic Evaluation Database for studies that evaluated the diagnostic accuracy of skin-prick and intradermal testing for allergic rhinitis using nasal provocation as the reference standard. For the clinical evidence review, data extraction and quality assessment were performed using the QUADAS-2 tool. We used the bivariate random-effects model for meta-analysis. For the economic evidence review, we assessed studies using a modified checklist developed by the (United Kingdom) National Institute for Health and Care Excellence. We estimated the annual cost of skin testing for allergic rhinitis in Ontario for 2015 to 2017 using provincial data on testing volumes and costs. We meta-analyzed seven studies with a total of 430 patients that assessed the accuracy of skin-prick testing. The pooled pair of sensitivity and specificity for skin-prick testing was 85% and 77%, respectively. We did not perform a meta-analysis for the diagnostic accuracy of intradermal testing due to the small number of studies (n = 4). Of these, two evaluated the accuracy of intradermal testing in confirming negative skin-prick testing results, with sensitivity ranging from 27% to 50% and specificity ranging from 60% to 100%. The other two studies evaluated the accuracy of intradermal testing as a stand-alone tool for diagnosing allergic rhinitis, with sensitivity ranging from 60% to 79% and specificity ranging from 68% to 69%. We estimated the budget impact of continuing to publicly fund skin testing for allergic rhinitis in Ontario to be between $2.5 million and $3.0 million per year. Skin-prick testing is moderately accurate in identifying subjects with or without allergic rhinitis. The diagnostic accuracy of intradermal testing could not be well established from this review. Our best estimate is that publicly funding skin testing for allergic rhinitis costs the Ontario government approximately $2.5 million to $3.0 million per year.

  7. Compensation of kinematic geometric parameters error and comparative study of accuracy testing for robot

    NASA Astrophysics Data System (ADS)

    Du, Liang; Shi, Guangming; Guan, Weibin; Zhong, Yuansheng; Li, Jin

    2014-12-01

    Geometric error is the main error of the industrial robot, and it plays a more significantly important fact than other error facts for robot. The compensation model of kinematic error is proposed in this article. Many methods can be used to test the robot accuracy, therefore, how to compare which method is better one. In this article, a method is used to compare two methods for robot accuracy testing. It used Laser Tracker System (LTS) and Three Coordinate Measuring instrument (TCM) to test the robot accuracy according to standard. According to the compensation result, it gets the better method which can improve the robot accuracy apparently.

  8. Thermocouple Calibration and Accuracy in a Materials Testing Laboratory

    NASA Technical Reports Server (NTRS)

    Lerch, B. A.; Nathal, M. V.; Keller, D. J.

    2002-01-01

    A consolidation of information has been provided that can be used to define procedures for enhancing and maintaining accuracy in temperature measurements in materials testing laboratories. These studies were restricted to type R and K thermocouples (TCs) tested in air. Thermocouple accuracies, as influenced by calibration methods, thermocouple stability, and manufacturer's tolerances were all quantified in terms of statistical confidence intervals. By calibrating specific TCs the benefits in accuracy can be as great as 6 C or 5X better compared to relying on manufacturer's tolerances. The results emphasize strict reliance on the defined testing protocol and on the need to establish recalibration frequencies in order to maintain these levels of accuracy.

  9. Value of physical tests in diagnosing cervical radiculopathy: a systematic review.

    PubMed

    Thoomes, Erik J; van Geest, Sarita; van der Windt, Danielle A; Falla, Deborah; Verhagen, Arianne P; Koes, Bart W; Thoomes-de Graaf, Marloes; Kuijper, Barbara; Scholten-Peeters, Wendy G M; Vleggeert-Lankamp, Carmen L

    2018-01-01

    In clinical practice, the diagnosis of cervical radiculopathy is based on information from the patient's history, physical examination, and diagnostic imaging. Various physical tests may be performed, but their diagnostic accuracy is unknown. This study aimed to summarize and update the evidence on diagnostic performance of tests carried out during a physical examination for the diagnosis of cervical radiculopathy. A review of the accuracy of diagnostic tests was carried out. The study sample comprised diagnostic studies comparing results of tests performed during a physical examination in diagnosing cervical radiculopathy with a reference standard of imaging or surgical findings. Sensitivity, specificity, likelihood ratios are presented, together with pooled results for sensitivity and specificity. A literature search up to March 2016 was performed in CENTRAL, PubMed (MEDLINE), Embase, CINAHL, Web of Science, and Google Scholar. The methodological quality of studies was assessed using the QUADAS-2. Five diagnostic accuracy studies were identified. Only Spurling's test was evaluated in more than one study, showing high specificity ranging from 0.89 to 1.00 (95% confidence interval [CI]: 0.59-1.00); sensitivity varied from 0.38 to 0.97 (95% CI: 0.21-0.99). No studies were found that assessed the diagnostic accuracy of widely used neurological tests such as key muscle strength, tendon reflexes, and sensory impairments. There is limited evidence for accuracy of physical examination tests for the diagnosis of cervical radiculopathy. When consistent with patient history, clinicians may use a combination of Spurling's, axial traction, and an Arm Squeeze test to increase the likelihood of a cervical radiculopathy, whereas a combined results of four negative neurodynamics tests and an Arm Squeeze test could be used to rule out the disorder. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Diagnostic Accuracy of the Neck Tornado Test as a New Screening Test in Cervical Radiculopathy

    PubMed Central

    Park, Juyeon; Park, Woo Young; Hong, Seungbae; An, Jiwon; Koh, Jae Chul; Lee, Youn-Woo; Kim, Yong Chan; Choi, Jong Bum

    2017-01-01

    Background: The Spurling test, although a highly specific provocative test of the cervical spine in cervical radiculopathy (CR), has low to moderate sensitivity. Thus, we introduced the neck tornado test (NTT) to examine the neck and the cervical spine in CR. Objectives: The aim of this study was to introduce a new provocative test, the NTT, and compare the diagnostic accuracy with a widely accepted provocative test, the Spurling test. Design: Retrospective study. Methods: Medical records of 135 subjects with neck pain (CR, n = 67; without CR, n = 68) who had undergone cervical spine magnetic resonance imaging and been referred to the pain clinic between September 2014 and August 2015 were reviewed. Both the Spurling test and NTT were performed in all patients by expert examiners. Sensitivity, specificity, and accuracy were compared for both the Spurling test and the NTT. Results: The sensitivity of the Spurling test and the NTT was 55.22% and 85.07% (P < 0.0001); specificity, 98.53% and 86.76% (P = 0.0026); accuracy, 77.04% and 85.93% (P = 0.0423), respectively. Conclusions: The NTT is more sensitive with superior diagnostic accuracy for CR diagnosed by magnetic resonance imaging than the Spurling test. PMID:28824298

  11. Effects of disease severity distribution on the performance of quantitative diagnostic methods and proposal of a novel 'V-plot' methodology to display accuracy values.

    PubMed

    Petraco, Ricardo; Dehbi, Hakim-Moulay; Howard, James P; Shun-Shin, Matthew J; Sen, Sayan; Nijjer, Sukhjinder S; Mayet, Jamil; Davies, Justin E; Francis, Darrel P

    2018-01-01

    Diagnostic accuracy is widely accepted by researchers and clinicians as an optimal expression of a test's performance. The aim of this study was to evaluate the effects of disease severity distribution on values of diagnostic accuracy as well as propose a sample-independent methodology to calculate and display accuracy of diagnostic tests. We evaluated the diagnostic relationship between two hypothetical methods to measure serum cholesterol (Chol rapid and Chol gold ) by generating samples with statistical software and (1) keeping the numerical relationship between methods unchanged and (2) changing the distribution of cholesterol values. Metrics of categorical agreement were calculated (accuracy, sensitivity and specificity). Finally, a novel methodology to display and calculate accuracy values was presented (the V-plot of accuracies). No single value of diagnostic accuracy can be used to describe the relationship between tests, as accuracy is a metric heavily affected by the underlying sample distribution. Our novel proposed methodology, the V-plot of accuracies, can be used as a sample-independent measure of a test performance against a reference gold standard.

  12. Liver fibrosis diagnosis by blood test and elastography in chronic hepatitis C: agreement or combination?

    PubMed

    Calès, P; Boursier, J; Lebigot, J; de Ledinghen, V; Aubé, C; Hubert, I; Oberti, F

    2017-04-01

    In chronic hepatitis C, the European Association for the Study of the Liver and the Asociacion Latinoamericana para el Estudio del Higado recommend performing transient elastography plus a blood test to diagnose significant fibrosis; test concordance confirms the diagnosis. To validate this rule and improve it by combining a blood test, FibroMeter (virus second generation, Echosens, Paris, France) and transient elastography (constitutive tests) into a single combined test, as suggested by the American Association for the Study of Liver Diseases and the Infectious Diseases Society of America. A total of 1199 patients were included in an exploratory set (HCV, n = 679) or in two validation sets (HCV ± HIV, HBV, n = 520). Accuracy was mainly evaluated by correct diagnosis rate for severe fibrosis (pathological Metavir F ≥ 3, primary outcome) by classical test scores or a fibrosis classification, reflecting Metavir staging, as a function of test concordance. Score accuracy: there were no significant differences between the blood test (75.7%), elastography (79.1%) and the combined test (79.4%) (P = 0.066); the score accuracy of each test was significantly (P < 0.001) decreased in discordant vs. concordant tests. Classification accuracy: combined test accuracy (91.7%) was significantly (P < 0.001) increased vs. the blood test (84.1%) and elastography (88.2%); accuracy of each constitutive test was significantly (P < 0.001) decreased in discordant vs. concordant tests but not with combined test: 89.0 vs. 92.7% (P = 0.118). Multivariate analysis for accuracy showed an interaction between concordance and fibrosis level: in the 1% of patients with full classification discordance and severe fibrosis, non-invasive tests were unreliable. The advantage of combined test classification was confirmed in the validation sets. The concordance recommendation is validated. A combined test, expressed in classification instead of score, improves this rule and validates the recommendation of a combined test, avoiding 99% of biopsies, and offering precise staging. © 2017 John Wiley & Sons Ltd.

  13. Test Expectancy Affects Metacomprehension Accuracy

    ERIC Educational Resources Information Center

    Thiede, Keith W.; Wiley, Jennifer; Griffin, Thomas D.

    2011-01-01

    Background: Theory suggests that the accuracy of metacognitive monitoring is affected by the cues used to judge learning. Researchers have improved monitoring accuracy by directing attention to more appropriate cues; however, this is the first study to more directly point students to more appropriate cues using instructions regarding tests and…

  14. A systematic review of the PTSD Checklist's diagnostic accuracy studies using QUADAS.

    PubMed

    McDonald, Scott D; Brown, Whitney L; Benesek, John P; Calhoun, Patrick S

    2015-09-01

    Despite the popularity of the PTSD Checklist (PCL) as a clinical screening test, there has been no comprehensive quality review of studies evaluating its diagnostic accuracy. A systematic quality assessment of 22 diagnostic accuracy studies of the English-language PCL using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) assessment tool was conducted to examine (a) the quality of diagnostic accuracy studies of the PCL, and (b) whether quality has improved since the 2003 STAndards for the Reporting of Diagnostic accuracy studies (STARD) initiative regarding reporting guidelines for diagnostic accuracy studies. Three raters independently applied the QUADAS tool to each study, and a consensus among the 4 authors is reported. Findings indicated that although studies generally met standards in several quality areas, there is still room for improvement. Areas for improvement include establishing representativeness, adequately describing clinical and demographic characteristics of the sample, and presenting better descriptions of important aspects of test and reference standard execution. Only 2 studies met each of the 14 quality criteria. In addition, study quality has not appreciably improved since the publication of the STARD Statement in 2003. Recommendations for the improvement of diagnostic accuracy studies of the PCL are discussed. (c) 2015 APA, all rights reserved).

  15. The urine dipstick test useful to rule out infections. A meta-analysis of the accuracy

    PubMed Central

    Devillé, Walter LJM; Yzermans, Joris C; van Duijn, Nico P; Bezemer, P Dick; van der Windt, Daniëlle AWM; Bouter, Lex M

    2004-01-01

    Background Many studies have evaluated the accuracy of dipstick tests as rapid detectors of bacteriuria and urinary tract infections (UTI). The lack of an adequate explanation for the heterogeneity of the dipstick accuracy stimulates an ongoing debate. The objective of the present meta-analysis was to summarise the available evidence on the diagnostic accuracy of the urine dipstick test, taking into account various pre-defined potential sources of heterogeneity. Methods Literature from 1990 through 1999 was searched in Medline and Embase, and by reference tracking. Selected publications should be concerned with the diagnosis of bacteriuria or urinary tract infections, investigate the use of dipstick tests for nitrites and/or leukocyte esterase, and present empirical data. A checklist was used to assess methodological quality. Results 70 publications were included. Accuracy of nitrites was high in pregnant women (Diagnostic Odds Ratio = 165) and elderly people (DOR = 108). Positive predictive values were ≥80% in elderly and in family medicine. Accuracy of leukocyte-esterase was high in studies in urology patients (DOR = 276). Sensitivities were highest in family medicine (86%). Negative predictive values were high in both tests in all patient groups and settings, except for in family medicine. The combination of both test results showed an important increase in sensitivity. Accuracy was high in studies in urology patients (DOR = 52), in children (DOR = 46), and if clinical information was present (DOR = 28). Sensitivity was highest in studies carried out in family medicine (90%). Predictive values of combinations of positive test results were low in all other situations. Conclusions Overall, this review demonstrates that the urine dipstick test alone seems to be useful in all populations to exclude the presence of infection if the results of both nitrites and leukocyte-esterase are negative. Sensitivities of the combination of both tests vary between 68 and 88% in different patient groups, but positive test results have to be confirmed. Although the combination of positive test results is very sensitive in family practice, the usefulness of the dipstick test alone to rule in infection remains doubtful, even with high pre-test probabilities. PMID:15175113

  16. Diagnostic accuracy of physical examination tests of the ankle/foot complex: a systematic review.

    PubMed

    Schwieterman, Braun; Haas, Deniele; Columber, Kirby; Knupp, Darren; Cook, Chad

    2013-08-01

    Orthopedic special tests of the ankle/foot complex are routinely used during the physical examination process in order to help diagnose ankle/lower leg pathologies. The purpose of this systematic review was to investigate the diagnostic accuracy of ankle/lower leg special tests. A search of the current literature was conducted using PubMed, CINAHL, SPORTDiscus, ProQuest Nursing and Allied Health Sources, Scopus, and Cochrane Library. Studies were eligible if they included the following: 1) a diagnostic clinical test of musculoskeletal pathology in the ankle/foot complex, 2) description of the clinical test or tests, 3) a report of the diagnostic accuracy of the clinical test (e.g. sensitivity and specificity), and 4) an acceptable reference standard for comparison. The quality of included studies was determined by two independent reviewers using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Nine diagnostic accuracy studies met the inclusion criteria for this systematic review; analyzing a total of 16 special tests of the ankle/foot complex. After assessment using the QUADAS-2, only one study had low risk of bias and low concerns regarding applicability. Most ankle/lower leg orthopedic special tests are confirmatory in nature and are best utilized at the end of the physical examination. Most of the studies included in this systematic review demonstrate notable biases, which suggest that results and recommendations in this review should be taken as a guide rather than an outright standard. There is need for future research with more stringent study design criteria so that more accurate diagnostic power of ankle/lower leg special tests can be determined. 3a.

  17. DIAGNOSTIC ACCURACY OF PHYSICAL EXAMINATION TESTS OF THE ANKLE/FOOT COMPLEX: A SYSTEMATIC REVIEW

    PubMed Central

    Schwieterman, Braun; Haas, Deniele; Columber, Kirby; Knupp, Darren

    2013-01-01

    Background: Orthopedic special tests of the ankle/foot complex are routinely used during the physical examination process in order to help diagnose ankle/lower leg pathologies. Purpose: The purpose of this systematic review was to investigate the diagnostic accuracy of ankle/lower leg special tests. Methods: A search of the current literature was conducted using PubMed, CINAHL, SPORTDiscus, ProQuest Nursing and Allied Health Sources, Scopus, and Cochrane Library. Studies were eligible if they included the following: 1) a diagnostic clinical test of musculoskeletal pathology in the ankle/foot complex, 2) description of the clinical test or tests, 3) a report of the diagnostic accuracy of the clinical test (e.g. sensitivity and specificity), and 4) an acceptable reference standard for comparison. The quality of included studies was determined by two independent reviewers using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool. Results: Nine diagnostic accuracy studies met the inclusion criteria for this systematic review; analyzing a total of 16 special tests of the ankle/foot complex. After assessment using the QUADAS-2, only one study had low risk of bias and low concerns regarding applicability. Conclusion: Most ankle/lower leg orthopedic special tests are confirmatory in nature and are best utilized at the end of the physical examination. Most of the studies included in this systematic review demonstrate notable biases, which suggest that results and recommendations in this review should be taken as a guide rather than an outright standard. There is need for future research with more stringent study design criteria so that more accurate diagnostic power of ankle/lower leg special tests can be determined. Level of Evidence: 3a PMID:24175128

  18. One process is not enough! A speed-accuracy tradeoff study of recognition memory.

    PubMed

    Boldini, Angela; Russo, Riccardo; Avons, S E

    2004-04-01

    Speed-accuracy tradeoff (SAT) methods have been used to contrast single- and dual-process accounts of recognition memory. In these procedures, subjects are presented with individual test items and are required to make recognition decisions under various time constraints. In this experiment, we presented word lists under incidental learning conditions, varying the modality of presentation and level of processing. At test, we manipulated the interval between each visually presented test item and a response signal, thus controlling the amount of time available to retrieve target information. Study-test modality match had a beneficial effect on recognition accuracy at short response-signal delays (< or =300 msec). Conversely, recognition accuracy benefited more from deep than from shallow processing at study only at relatively long response-signal delays (> or =300 msec). The results are congruent with views suggesting that both fast familiarity and slower recollection processes contribute to recognition memory.

  19. Fundamental Importance of Reference Glucose Analyzer Accuracy for Evaluating the Performance of Blood Glucose Monitoring Systems (BGMSs).

    PubMed

    Bailey, Timothy S; Klaff, Leslie J; Wallace, Jane F; Greene, Carmine; Pardo, Scott; Harrison, Bern; Simmons, David A

    2016-07-01

    As blood glucose monitoring system (BGMS) accuracy is based on comparison of BGMS and laboratory reference glucose analyzer results, reference instrument accuracy is important to discriminate small differences between BGMS and reference glucose analyzer results. Here, we demonstrate the important role of reference glucose analyzer accuracy in BGMS accuracy evaluations. Two clinical studies assessed the performance of a new BGMS, using different reference instrument procedures. BGMS and YSI analyzer results were compared for fingertip blood that was obtained by untrained subjects' self-testing and study staff testing, respectively. YSI analyzer accuracy was monitored using traceable serum controls. In study 1 (N = 136), 94.1% of BGMS results were within International Organization for Standardization (ISO) 15197:2013 accuracy criteria; YSI analyzer serum control results showed a negative bias (-0.64% to -2.48%) at the first site and a positive bias (3.36% to 6.91%) at the other site. In study 2 (N = 329), 97.8% of BGMS results were within accuracy criteria; serum controls showed minimal bias (<0.92%) at both sites. These findings suggest that the ability to demonstrate that a BGMS meets accuracy guidelines is influenced by reference instrument accuracy. © 2016 Diabetes Technology Society.

  20. The effect of storage temperature on the accuracy of a cow-side test for ketosis

    PubMed Central

    Hubbard, Jennifer; LeBlanc, Stephen; Duffield, Todd; Bagg, Randal; Dubuc, Jocelyn

    2010-01-01

    The objective of this study was to assess the effect of storage conditions on the accuracy of a milk test strip for ketosis. Storage at 21°C for up to 18 wk had little effect on accuracy for diagnosis and classification of subclinical ketosis. PMID:20676298

  1. Recommended reporting standards for test accuracy studies of infectious diseases of finfish, amphibians, molluscs and crustaceans: the STRADAS-aquatic checklist.

    PubMed

    Gardner, Ian A; Whittington, Richard J; Caraguel, Charles G B; Hick, Paul; Moody, Nicholas J G; Corbeil, Serge; Garver, Kyle A; Warg, Janet V; Arzul, Isabelle; Purcell, Maureen K; Crane, Mark St J; Waltzek, Thomas B; Olesen, Niels J; Gallardo Lagno, Alicia

    2016-02-25

    Complete and transparent reporting of key elements of diagnostic accuracy studies for infectious diseases in cultured and wild aquatic animals benefits end-users of these tests, enabling the rational design of surveillance programs, the assessment of test results from clinical cases and comparisons of diagnostic test performance. Based on deficiencies in the Standards for Reporting of Diagnostic Accuracy (STARD) guidelines identified in a prior finfish study (Gardner et al. 2014), we adapted the Standards for Reporting of Animal Diagnostic Accuracy Studies-paratuberculosis (STRADAS-paraTB) checklist of 25 reporting items to increase their relevance to finfish, amphibians, molluscs, and crustaceans and provided examples and explanations for each item. The checklist, known as STRADAS-aquatic, was developed and refined by an expert group of 14 transdisciplinary scientists with experience in test evaluation studies using field and experimental samples, in operation of reference laboratories for aquatic animal pathogens, and in development of international aquatic animal health policy. The main changes to the STRADAS-paraTB checklist were to nomenclature related to the species, the addition of guidelines for experimental challenge studies, and the designation of some items as relevant only to experimental studies and ante-mortem tests. We believe that adoption of these guidelines will improve reporting of primary studies of test accuracy for aquatic animal diseases and facilitate assessment of their fitness-for-purpose. Given the importance of diagnostic tests to underpin the Sanitary and Phytosanitary agreement of the World Trade Organization, the principles outlined in this paper should be applied to other World Organisation for Animal Health (OIE)-relevant species.

  2. Test Accuracy of Informant-Based Cognitive Screening Tests for Diagnosis of Dementia and Multidomain Cognitive Impairment in Stroke.

    PubMed

    McGovern, Aine; Pendlebury, Sarah T; Mishra, Nishant K; Fan, Yuhua; Quinn, Terence J

    2016-02-01

    Poststroke cognitive assessment can be performed using standardized questionnaires designed for family or care givers. We sought to describe the test accuracy of such informant-based assessments for diagnosis of dementia/multidomain cognitive impairment in stroke. We performed a systematic review using a sensitive search strategy across multidisciplinary electronic databases. We created summary test accuracy metrics and described reporting and quality using STARDdem and Quality Assessment of Diagnostic Accuracy Studies (QUADAS) tools, respectively. From 1432 titles, we included 11 studies. Ten papers used the Informant Questionnaire on Cognitive Decline in the Elderly (IQCODE). Four studies described IQCODE for diagnosis of poststroke dementia (n=1197); summary sensitivity: 0.81 (95% confidence interval, 0.60-0.93); summary specificty: 0.83 (95% confidence interval, 0.64-0.93). Five studies described IQCODE as tool for predicting future dementia (n=837); summary sensitivity: 0.60 (95% confidence interval, 0.32-0.83); summary specificity: 0.97 (95% confidence interval, 0.70-1.00). All papers had issues with at least 1 aspect of study reporting or quality. There is a limited literature on informant cognitive assessments in stroke. IQCODE as a diagnostic tool has test properties similar to other screening tools, IQCODE as a prognostic tool is specific but insensitive. We found no papers describing test accuracy of informant tests for diagnosis of prestroke cognitive decline, few papers on poststroke dementia and all included papers had issues with potential bias. © 2015 American Heart Association, Inc.

  3. Diagnostic accuracy of scapular physical examination tests for shoulder disorders: a systematic review.

    PubMed

    Wright, Alexis A; Wassinger, Craig A; Frank, Mason; Michener, Lori A; Hegedus, Eric J

    2013-09-01

    To systematically review and critique the evidence regarding the diagnostic accuracy of physical examination tests for the scapula in patients with shoulder disorders. A systematic, computerised literature search of PubMED, EMBASE, CINAHL and the Cochrane Library databases (from database inception through January 2012) using keywords related to diagnostic accuracy of physical examination tests of the scapula. The Quality Assessment of Diagnostic Accuracy Studies tool was used to critique the quality of each paper. Eight articles met the inclusion criteria; three were considered to be of high quality. Of the three high-quality studies, two were in reference to a 'diagnosis' of shoulder pain. Only one high-quality article referenced specific shoulder pathology of acromioclavicular dislocation with reported sensitivity of 71% and 41% for the scapular dyskinesis and SICK scapula test, respectively. Overall, no physical examination test of the scapula was found to be useful in differentially diagnosing pathologies of the shoulder.

  4. Influence of Fine Motor Skill on Accuracy of Measurements Using a Handheld Sliding Caliper at Adolescents Group Aged 19-20

    NASA Astrophysics Data System (ADS)

    Brychta, Petr; Hojk, Vladimír; Hrubý, Jiří; Pilc, Jozef

    2017-10-01

    This innovate ve interdisciplinary study deals with influence of fine motor skill level (finger dexterity) of individual on his measurement results in metrology practice. The main objective of this study was determinate fine motor skill level of individuals using a motor test. Further determinate the potential effect of different fine motor skill levels on accuracy of measuring using a mechanical handheld sliding caliper. Fine motor skill test and metrological test were implemented. Pursuant the results of fine motor skill test were probands divided into 2 groups. The groups are significantly different on accuracy of measurement (p=0,006). Pearson coefficient shows a significant correlation r = - 0.66 between the Purdue Pegboard test and a measurement error. Results confirmed that the fine motor skill of the upper limbs (especially finger coordination) significantly influence accuracy of measurement using a mechanical handheld sliding caliper.

  5. Efficient strategies to find diagnostic test accuracy studies in kidney journals.

    PubMed

    Rogerson, Thomas E; Ladhani, Maleeka; Mitchell, Ruth; Craig, Jonathan C; Webster, Angela C

    2015-08-01

    Nephrologists looking for quick answers to diagnostic clinical questions in MEDLINE can use a range of published search strategies or Clinical Query limits to improve the precision of their searches. We aimed to evaluate existing search strategies for finding diagnostic test accuracy studies in nephrology journals. We assessed the accuracy of 14 search strategies for retrieving diagnostic test accuracy studies from three nephrology journals indexed in MEDLINE. Two investigators hand searched the same journals to create a reference set of diagnostic test accuracy studies to compare search strategy results against. We identified 103 diagnostic test accuracy studies, accounting for 2.1% of all studies published. The most specific search strategy was the Narrow Clinical Queries limit (sensitivity: 0.20, 95% CI 0.13-0.29; specificity: 0.99, 95% CI 0.99-0.99). Using the Narrow Clinical Queries limit, a searcher would need to screen three (95% CI 2-6) articles to find one diagnostic study. The most sensitive search strategy was van der Weijden 1999 Extended (sensitivity: 0.95; 95% CI 0.89-0.98; specificity 0.55, 95% CI 0.53-0.56) but required a searcher to screen 24 (95% CI 23-26) articles to find one diagnostic study. Bachmann 2002 was the best balanced search strategy, which was sensitive (0.88, 95% CI 0.81-0.94), but also specific (0.74, 95% CI 0.73-0.75), with a number needed to screen of 15 (95% CI 14-17). Diagnostic studies are infrequently published in nephrology journals. The addition of a strategy for diagnostic studies to a subject search strategy in MEDLINE may reduce the records needed to screen while preserving adequate search sensitivity for routine clinical use. © 2015 Asian Pacific Society of Nephrology.

  6. The diagnostic accuracy of serological tests for Lyme borreliosis in Europe: a systematic review and meta-analysis.

    PubMed

    Leeflang, M M G; Ang, C W; Berkhout, J; Bijlmer, H A; Van Bortel, W; Brandenburg, A H; Van Burgel, N D; Van Dam, A P; Dessau, R B; Fingerle, V; Hovius, J W R; Jaulhac, B; Meijer, B; Van Pelt, W; Schellekens, J F P; Spijker, R; Stelma, F F; Stanek, G; Verduyn-Lunel, F; Zeller, H; Sprong, H

    2016-03-25

    Interpretation of serological assays in Lyme borreliosis requires an understanding of the clinical indications and the limitations of the currently available tests. We therefore systematically reviewed the accuracy of serological tests for the diagnosis of Lyme borreliosis in Europe. We searched EMBASE en MEDLINE and contacted experts. Studies evaluating the diagnostic accuracy of serological assays for Lyme borreliosis in Europe were eligible. Study selection and data-extraction were done by two authors independently. We assessed study quality using the QUADAS-2 checklist. We used a hierarchical summary ROC meta-regression method for the meta-analyses. Potential sources of heterogeneity were test-type, commercial or in-house, Ig-type, antigen type and study quality. These were added as covariates to the model, to assess their effect on test accuracy. Seventy-eight studies evaluating an Enzyme-Linked ImmunoSorbent assay (ELISA) or an immunoblot assay against a reference standard of clinical criteria were included. None of the studies had low risk of bias for all QUADAS-2 domains. Sensitivity was highly heterogeneous, with summary estimates: erythema migrans 50% (95% CI 40% to 61%); neuroborreliosis 77% (95% CI 67% to 85%); acrodermatitis chronica atrophicans 97% (95% CI 94% to 99%); unspecified Lyme borreliosis 73% (95% CI 53% to 87%). Specificity was around 95% in studies with healthy controls, but around 80% in cross-sectional studies. Two-tiered algorithms or antibody indices did not outperform single test approaches. The observed heterogeneity and risk of bias complicate the extrapolation of our results to clinical practice. The usefulness of the serological tests for Lyme disease depends on the pre-test probability and subsequent predictive values in the setting where the tests are being used. Future diagnostic accuracy studies should be prospectively planned cross-sectional studies, done in settings where the test will be used in practice.

  7. Recommended reporting standards for test accuracy studies of infectious diseases of finfish, amphibians, molluscs and crustaceans: the STRADAS-aquatic checklist

    USGS Publications Warehouse

    Gardner, Ian A; Whittington, Richard J; Caraguel, Charles G B; Hick, Paul; Moody, Nicholas J G; Corbeil, Serge; Garver, Kyle A.; Warg, Janet V.; Arzul, Isabelle; Purcell, Maureen; St. J. Crane, Mark; Waltzek, Thomas B.; Olesen, Niels J; Lagno, Alicia Gallardo

    2016-01-01

    Complete and transparent reporting of key elements of diagnostic accuracy studies for infectious diseases in cultured and wild aquatic animals benefits end-users of these tests, enabling the rational design of surveillance programs, the assessment of test results from clinical cases and comparisons of diagnostic test performance. Based on deficiencies in the Standards for Reporting of Diagnostic Accuracy (STARD) guidelines identified in a prior finfish study (Gardner et al. 2014), we adapted the Standards for Reporting of Animal Diagnostic Accuracy Studies—paratuberculosis (STRADAS-paraTB) checklist of 25 reporting items to increase their relevance to finfish, amphibians, molluscs, and crustaceans and provided examples and explanations for each item. The checklist, known as STRADAS-aquatic, was developed and refined by an expert group of 14 transdisciplinary scientists with experience in test evaluation studies using field and experimental samples, in operation of reference laboratories for aquatic animal pathogens, and in development of international aquatic animal health policy. The main changes to the STRADAS-paraTB checklist were to nomenclature related to the species, the addition of guidelines for experimental challenge studies, and the designation of some items as relevant only to experimental studies and ante-mortem tests. We believe that adoption of these guidelines will improve reporting of primary studies of test accuracy for aquatic animal diseases and facilitate assessment of their fitness-for-purpose. Given the importance of diagnostic tests to underpin the Sanitary and Phytosanitary agreement of the World Trade Organization, the principles outlined in this paper should be applied to other World Organisation for Animal Health (OIE)-relevant species.

  8. A Multivariate Multilevel Approach to the Modeling of Accuracy and Speed of Test Takers

    ERIC Educational Resources Information Center

    Klein Entink, R. H.; Fox, J. P.; van der Linden, W. J.

    2009-01-01

    Response times on test items are easily collected in modern computerized testing. When collecting both (binary) responses and (continuous) response times on test items, it is possible to measure the accuracy and speed of test takers. To study the relationships between these two constructs, the model is extended with a multivariate multilevel…

  9. Placental growth factor (alone or in combination with soluble fms-like tyrosine kinase 1) as an aid to the assessment of women with suspected pre-eclampsia: systematic review and economic analysis.

    PubMed

    Frampton, Geoff K; Jones, Jeremy; Rose, Micah; Payne, Liz

    2016-11-01

    Pre-eclampsia (PE) prediction based on blood pressure, presence of protein in the urine, symptoms and laboratory test abnormalities can result in false-positive diagnoses. This may lead to unnecessary antenatal admissions and preterm delivery. Blood tests that measure placental growth factor (PlGF) or the ratio of soluble fms-like tyrosine kinase 1 (sFlt-1) to PlGF could aid prediction of PE if either were added to routine clinical assessment or used as a replacement for proteinuria testing. To evaluate the diagnostic accuracy and cost-effectiveness of PlGF-based tests for patients referred to secondary care with suspected PE in weeks 20-37 of pregnancy. Systematic reviews and an economic analysis. Bibliographic databases including MEDLINE, EMBASE, Web of Science and The Cochrane Library and Database of Abstracts of Reviews of Effects were searched up to July 2015 for English-language references. Conferences, websites, systematic reviews and confidential company submissions were also accessed. Systematic reviews of test accuracy and economic studies were conducted to inform an economic analysis. Test accuracy studies were required to include women with suspected PE and report quantitatively the accuracy of PlGF-based tests; their risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) criteria. The economic studies review had broad eligibility criteria to capture any types of economic analysis; critical appraisal employed standard checklists consistent with National Institute for Health and Care Excellence criteria. Study selection, critical appraisal and data extraction in both reviews were performed by two reviewers. An independent economic analysis was conducted based on a decision tree model, using the best evidence available. The model evaluates costs (2014, GBP) from a NHS and Personal Social Services perspective. Given the short analysis time horizon, no discounting was undertaken. Four studies were included in the systematic review of test accuracy: two on Alere's Triage ® PlGF test (Alere, Inc., San Diego, CA, USA) for predicting PE requiring delivery within a specified time and two on Roche Diagnostics' Elecsys ® sFlt-1 to PlGF ratio test (Roche Diagnostics GmbH, Mannheim, Germany) for predicting PE within a specified time. Three studies were included in the systematic review of economic studies, and two confidential company economic analyses were assessed separately. Study heterogeneity precluded meta-analyses of test accuracy or cost-analysis outcomes, so narrative syntheses were conducted to inform the independent economic model. The model predicts that, when supplementing routine clinical assessment for rule-out and rule-in of PE, the two tests would be cost-saving in weeks 20-35 of gestation, and marginally cost-saving in weeks 35-37, but with minuscule impact on quality of life. Length of neonatal intensive care unit stay was the most influential parameter in sensitivity analyses. All other sensitivity analyses had negligible effects on results. No head-to-head comparisons of the tests were identified. No studies investigated accuracy of PlGF-based tests when used as a replacement for proteinuria testing. Test accuracy studies were found to be at high risk of clinical review bias. The Triage and Elecsys tests would save money if added to routine clinical assessment for PE. The magnitude of savings is uncertain, but the tests remain cost-saving under worst-case assumptions. Further research is required to clarify how the test results would be interpreted and applied in clinical practice. This study is registered as PROSPERO CRD42015017670. The National Institute for Health Research Health Technology Assessment programme.

  10. The diagnostic test accuracy of magnetic resonance imaging, magnetic resonance arthrography and computer tomography in the detection of chondral lesions of the hip.

    PubMed

    Smith, Toby O; Simpson, Michael; Ejindu, Vivian; Hing, Caroline B

    2013-04-01

    The purpose of this study was to assess the diagnostic test accuracy of magnetic resonance imaging (MRI), magnetic resonance arthrography (MRA) and multidetector arrays in CT arthrography (MDCT) for assessing chondral lesions in the hip joint. A review of the published and unpublished literature databases was performed to identify all studies reporting the diagnostic test accuracy (sensitivity/specificity) of MRI, MRA or MDCT for the assessment of adults with chondral (cartilage) lesions of the hip with surgical comparison (arthroscopic or open) as the reference test. All included studies were reviewed using the quality assessment of diagnostic accuracy studies appraisal tool. Pooled sensitivity, specificity, likelihood ratios and diagnostic odds ratios were calculated with 95 % confidence intervals using a random-effects meta-analysis for MRI, MRA and MDCT imaging. Eighteen studies satisfied the eligibility criteria. These included 648 hips from 637 patients. MRI indicated a pooled sensitivity of 0.59 (95 % CI: 0.49-0.70) and specificity of 0.94 (95 % CI: 0.90-0.97), and MRA sensitivity and specificity values were 0.62 (95 % CI: 0.57-0.66) and 0.86 (95 % CI: 0.83-0.89), respectively. The diagnostic test accuracy for the detection of hip joint cartilage lesions is currently superior for MRI compared with MRA. There were insufficient data to perform meta-analysis for MDCT or CTA protocols. Based on the current limited diagnostic test accuracy of the use of magnetic resonance or CT, arthroscopy remains the most accurate method of assessing chondral lesions in the hip joint.

  11. The STARD statement for reporting diagnostic accuracy studies: application to the history and physical examination.

    PubMed

    Simel, David L; Rennie, Drummond; Bossuyt, Patrick M M

    2008-06-01

    The Standards for Reporting of Diagnostic Accuracy (STARD) statement provided guidelines for investigators conducting diagnostic accuracy studies. We reviewed each item in the statement for its applicability to clinical examination diagnostic accuracy research, viewing each discrete aspect of the history and physical examination as a diagnostic test. Nonsystematic review of the STARD statement. Two former STARD Group participants and 1 editor of a journal series on clinical examination research reviewed each STARD item. Suggested interpretations and comments were shared to develop consensus. The STARD Statement applies generally well to clinical examination diagnostic accuracy studies. Three items are the most important for clinical examination diagnostic accuracy studies, and investigators should pay particular attention to their requirements: describe carefully the patient recruitment process, describe participant sampling and address if patients were from a consecutive series, and describe whether the clinicians were masked to the reference standard tests and whether the interpretation of the reference standard test was masked to the clinical examination components or overall clinical impression. The consideration of these and the other STARD items in clinical examination diagnostic research studies would improve the quality of investigations and strengthen conclusions reached by practicing clinicians. The STARD statement provides a very useful framework for diagnostic accuracy studies. The group correctly anticipated that there would be nuances applicable to studies of the clinical examination. We offer guidance that should enhance their usefulness to investigators embarking on original studies of a patient's history and physical examination.

  12. [In vivo model to evaluate the accuracy of complete-tooth spectrophotometer for dental clinics].

    PubMed

    Liu, Feng; Yang, Jian; Xu, Tong-Kai; Xu, Ming-Ming; Ma, Yu

    2011-02-01

    To test ΔE between measured value and right value from the Crystaleye complete-tooth spectrophotometer, and to evaluate the accuracy rate of the spectrophotometer. Twenty prosthodontists participated in the study. Each of them used Vita 3D-Master shadeguide to do the shade matching, and used Crystaleye complete-tooth spectrophotometer (before and after the test training) tested the middle of eight fixed tabs from shadeguide in the dark box. The results of shade matching and spectrophotometer were recorded. The accuracy rate of shade matching and the spectrophotometer before and after training were calculated. The average accuracy rate of shade matching was 49%. The average accuracy rate of the spectrophotometer before and after training was 83% and 99%. The accuracy of the spectrophotometer was significant higher than that in shade matching, and training can improve the accuracy rate.

  13. Fundamental Importance of Reference Glucose Analyzer Accuracy for Evaluating the Performance of Blood Glucose Monitoring Systems (BGMSs)

    PubMed Central

    Bailey, Timothy S.; Klaff, Leslie J.; Wallace, Jane F.; Greene, Carmine; Pardo, Scott; Harrison, Bern; Simmons, David A.

    2016-01-01

    Background: As blood glucose monitoring system (BGMS) accuracy is based on comparison of BGMS and laboratory reference glucose analyzer results, reference instrument accuracy is important to discriminate small differences between BGMS and reference glucose analyzer results. Here, we demonstrate the important role of reference glucose analyzer accuracy in BGMS accuracy evaluations. Methods: Two clinical studies assessed the performance of a new BGMS, using different reference instrument procedures. BGMS and YSI analyzer results were compared for fingertip blood that was obtained by untrained subjects’ self-testing and study staff testing, respectively. YSI analyzer accuracy was monitored using traceable serum controls. Results: In study 1 (N = 136), 94.1% of BGMS results were within International Organization for Standardization (ISO) 15197:2013 accuracy criteria; YSI analyzer serum control results showed a negative bias (−0.64% to −2.48%) at the first site and a positive bias (3.36% to 6.91%) at the other site. In study 2 (N = 329), 97.8% of BGMS results were within accuracy criteria; serum controls showed minimal bias (<0.92%) at both sites. Conclusions: These findings suggest that the ability to demonstrate that a BGMS meets accuracy guidelines is influenced by reference instrument accuracy. PMID:26902794

  14. Accuracy of four commonly used color vision tests in the identification of cone disorders.

    PubMed

    Thiadens, Alberta A H J; Hoyng, Carel B; Polling, Jan Roelof; Bernaerts-Biskop, Riet; van den Born, L Ingeborgh; Klaver, Caroline C W

    2013-04-01

    To determine which color vision test is most appropriate for the identification of cone disorders. In a clinic-based study, four commonly used color vision tests were compared between patients with cone dystrophy (n = 37), controls with normal visual acuity (n = 35), and controls with low vision (n = 39) and legal blindness (n = 11). Mean outcome measures were specificity, sensitivity, positive predictive value and discriminative accuracy of the Ishihara test, Hardy-Rand-Rittler (HRR) test, and the Lanthony and Farnsworth Panel D-15 tests. In the comparison between cone dystrophy and all controls, sensitivity, specificity and predictive value were highest for the HRR and Ishihara tests. When patients were compared to controls with normal vision, discriminative accuracy was highest for the HRR test (c-statistic for PD-axes 1, for T-axis 0.851). When compared to controls with poor vision, discriminative accuracy was again highest for the HRR test (c-statistic for PD-axes 0.900, for T-axis 0.766), followed by the Lanthony Panel D-15 test (c-statistic for PD-axes 0.880, for T-axis 0.500) and Ishihara test (c-statistic 0.886). Discriminative accuracies of all tests did not further decrease when patients were compared to controls who were legally blind. The HRR, Lanthony Panel D-15 and Ishihara all have a high discriminative accuracy to identify cone disorders, but the highest scores were for the HRR test. Poor visual acuity slightly decreased the accuracy of all tests. Our advice is to use the HRR test since this test also allows for evaluation of all three color axes and quantification of color defects.

  15. Physical examination tests for the diagnosis of femoroacetabular impingement. A systematic review.

    PubMed

    Pacheco-Carrillo, Aitana; Medina-Porqueres, Ivan

    2016-09-01

    Numerous clinical tests have been proposed to diagnose FAI, but little is known about their diagnostic accuracy. To summarize and evaluate research on the accuracy of physical examination tests for diagnosis of FAI. A search of the PubMed, SPORTDiscus and CINAHL databases was performed. Studies were considered eligible if they compared the results of physical examination tests to those of a reference standard. Methodological quality and internal validity assessment was performed by two independent reviewers using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) tool. The systematic search strategy revealed 298 potential articles, five of which articles met the inclusion criteria. After assessment using the QUADAS score, four of the five articles were of high quality. Clinical tests included were Impingement sign, IROP test (Internal Rotation Over Pressure), FABER test (Flexion-Abduction-External Rotation), Stinchfield/RSRL (Resisted Straight Leg Raise) test, Scour test, Maximal squat test, and the Anterior Impingement test. IROP test, impingement sign, and FABER test showed the most sensitive values to identify FAI. The diagnostic accuracy of physical examination tests to assess FAI is limited due to its heterogenecity. There is a strong need for sound research of high methodological quality in this area. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Diagnostic accuracy research in glaucoma is still incompletely reported: An application of Standards for Reporting of Diagnostic Accuracy Studies (STARD) 2015.

    PubMed

    Michelessi, Manuele; Lucenteforte, Ersilia; Miele, Alba; Oddone, Francesco; Crescioli, Giada; Fameli, Valeria; Korevaar, Daniël A; Virgili, Gianni

    2017-01-01

    Research has shown a modest adherence of diagnostic test accuracy (DTA) studies in glaucoma to the Standards for Reporting of Diagnostic Accuracy Studies (STARD). We have applied the updated 30-item STARD 2015 checklist to a set of studies included in a Cochrane DTA systematic review of imaging tools for diagnosing manifest glaucoma. Three pairs of reviewers, including one senior reviewer who assessed all studies, independently checked the adherence of each study to STARD 2015. Adherence was analyzed on an individual-item basis. Logistic regression was used to evaluate the effect of publication year and impact factor on adherence. We included 106 DTA studies, published between 2003-2014 in journals with a median impact factor of 2.6. Overall adherence was 54.1% for 3,286 individual rating across 31 items, with a mean of 16.8 (SD: 3.1; range 8-23) items per study. Large variability in adherence to reporting standards was detected across individual STARD 2015 items, ranging from 0 to 100%. Nine items (1: identification as diagnostic accuracy study in title/abstract; 6: eligibility criteria; 10: index test (a) and reference standard (b) definition; 12: cut-off definitions for index test (a) and reference standard (b); 14: estimation of diagnostic accuracy measures; 21a: severity spectrum of diseased; 23: cross-tabulation of the index and reference standard results) were adequately reported in more than 90% of the studies. Conversely, 10 items (3: scientific and clinical background of the index test; 11: rationale for the reference standard; 13b: blinding of index test results; 17: analyses of variability; 18; sample size calculation; 19: study flow diagram; 20: baseline characteristics of participants; 28: registration number and registry; 29: availability of study protocol; 30: sources of funding) were adequately reported in less than 30% of the studies. Only four items showed a statistically significant improvement over time: missing data (16), baseline characteristics of participants (20), estimates of diagnostic accuracy (24) and sources of funding (30). Adherence to STARD 2015 among DTA studies in glaucoma research is incomplete, and only modestly increasing over time.

  17. The methodological quality of diagnostic test accuracy studies for musculoskeletal conditions can be improved.

    PubMed

    Henschke, Nicholas; Keuerleber, Julia; Ferreira, Manuela; Maher, Christopher G; Verhagen, Arianne P

    2014-04-01

    To provide an overview of reporting and methodological quality in diagnostic test accuracy (DTA) studies in the musculoskeletal field and evaluate the use of the QUality Assessment of Diagnostic Accuracy Studies (QUADAS) checklist. A literature review identified all systematic reviews that evaluated the accuracy of clinical tests to diagnose musculoskeletal conditions and used the QUADAS checklist. Two authors screened all identified reviews and extracted data on the target condition, index tests, reference standard, included studies, and QUADAS items. A descriptive analysis of the QUADAS checklist was performed, along with Rasch analysis to examine the construct validity and internal reliability. A total of 19 systematic reviews were included, which provided data on individual items of the QUADAS checklist for 392 DTA studies. In the musculoskeletal field, uninterpretable or intermediate test results are commonly not reported, with 175 (45%) studies scoring "no" to this item. The proportion of studies fulfilling certain items varied from 22% (item 11) to 91% (item 3). The interrater reliability of the QUADAS checklist was good and Rasch analysis showed excellent construct validity and internal consistency. This overview identified areas where the reporting and performance of diagnostic studies within the musculoskeletal field can be improved. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Improved Motor-Timing: Effects of Synchronized Metro-Nome Training on Golf Shot Accuracy

    PubMed Central

    Sommer, Marius; Rönnqvist, Louise

    2009-01-01

    This study investigates the effect of synchronized metronome training (SMT) on motor timing and how this training might affect golf shot accuracy. Twenty-six experienced male golfers participated (mean age 27 years; mean golf handicap 12.6) in this study. Pre- and post-test investigations of golf shots made by three different clubs were conducted by use of a golf simulator. The golfers were randomized into two groups: a SMT group and a Control group. After the pre-test, the golfers in the SMT group completed a 4-week SMT program designed to improve their motor timing, the golfers in the Control group were merely training their golf-swings during the same time period. No differences between the two groups were found from the pre-test outcomes, either for motor timing scores or for golf shot accuracy. However, the post-test results after the 4-weeks SMT showed evident motor timing improvements. Additionally, significant improvements for golf shot accuracy were found for the SMT group and with less variability in their performance. No such improvements were found for the golfers in the Control group. As with previous studies that used a SMT program, this study’s results provide further evidence that motor timing can be improved by SMT and that such timing improvement also improves golf accuracy. Key points This study investigates the effect of synchronized metronome training (SMT) on motor timing and how this training might affect golf shot accuracy. A randomized control group design was used. The 4 week SMT intervention showed significant improvements in motor timing, golf shot accuracy, and lead to less variability. We conclude that this study’s results provide further evidence that motor timing can be improved by SMT training and that such timing improvement also improves golf accuracy. PMID:24149608

  19. The Role of Incidental Unfocused Prompts and Recasts in Improving English as a Foreign Language Learners' Accuracy

    ERIC Educational Resources Information Center

    Rahimi, Muhammad; Zhang, Lawrence Jun

    2016-01-01

    This study was designed to investigate the effects of incidental unfocused prompts and recasts on improving English as a foreign language (EFL) learners' grammatical accuracy as measured in students' oral interviews and the Test of English as a Foreign Language (TOEFL) grammar test. The design of the study was quasi-experimental with pre-tests,…

  20. Assessment of data quality of and staff satisfaction with an electronic health record system in a developing country (Uganda): a qualitative and quantitative comparative study.

    PubMed

    Ndira, S P; Rosenberger, K D; Wetter, T

    2008-01-01

    To assess if electronic health record systems in developing countries can improve on timeliness, availability and accuracy of routine health reports and staff satisfaction after introducing the electronic system, compared to the paper-based alternative. The research was conducted with hospital staff of Tororo District Hospital in Uganda. A comparative intervention study with qualitative and quantitative methods was used to compare the paper-based (pre-test) to the electronic system (post-test) focusing on accuracy, availability and timeliness of monthly routine reports about mothers visiting the hospital; and staff satisfaction with the electronic system as outcome measures. Timeliness: pre-test 13 of 19 months delivered to the district timely, delivery dates for six months could not be established; post-test 100%. pre-test 79% of reports were present at the district health office; post-test 100%. Accuracy: pre-test 73.2% of selected reports could be independently confirmed as correct; post-test 71.2%. Difficulties were encountered in finding enough mothers through direct follow up to inquire on accuracy of information recorded about them. Staff interviews showed that the electronic system is appreciated by the majority of the hospital staff. Remaining obstacles include staff workload, power shortages, network breakdowns and parallel data entry (paper-based and electronic). While timeliness and availability improved, improvement of accuracy could not be established. Better approaches to ascertaining accuracy have to be devised, e.g. evaluation of intended use. For success, organizational, managerial and social challenges must be addressed beyond technical aspects.

  1. Diagnostic Accuracy of the Slump Test for Identifying Neuropathic Pain in the Lower Limb.

    PubMed

    Urban, Lawrence M; MacNeil, Brian J

    2015-08-01

    Diagnostic accuracy study with nonconsecutive enrollment. To assess the diagnostic accuracy of the slump test for neuropathic pain (NeP) in those with low to moderate levels of chronic low back pain (LBP), and to determine whether accuracy of the slump test improves by adding anatomical or qualitative pain descriptors. Neuropathic pain has been linked with poor outcomes, likely due to inadequate diagnosis, which precludes treatment specific for NeP. Current diagnostic approaches are time consuming or lack accuracy. A convenience sample of 21 individuals with LBP, with or without radiating leg pain, was recruited. A standardized neurosensory examination was used to determine the reference diagnosis for NeP. Afterward, the slump test was administered to all participants. Reports of pain location and quality produced during the slump test were recorded. The neurosensory examination designated 11 of the 21 participants with LBP/sciatica as having NeP. The slump test displayed high sensitivity (0.91), moderate specificity (0.70), a positive likelihood ratio of 3.03, and a negative likelihood ratio of 0.13. Adding the criterion of pain below the knee significantly increased specificity to 1.00 (positive likelihood ratio = 11.9). Pain-quality descriptors did not improve diagnostic accuracy. The slump test was highly sensitive in identifying NeP within the study sample. Adding a pain-location criterion improved specificity. Combining the diagnostic outcomes was very effective in identifying all those without NeP and half of those with NeP. Limitations arising from the small and narrow spectrum of participants with LBP/sciatica sampled within the study prevent application of the findings to a wider population. Diagnosis, level 4-.

  2. Illusory expectations can affect retrieval-monitoring accuracy.

    PubMed

    McDonough, Ian M; Gallo, David A

    2012-03-01

    The present study investigated how expectations, even when illusory, can affect the accuracy of memory decisions. Participants studied words presented in large or small font for subsequent memory tests. Replicating prior work, judgments of learning indicated that participants expected to remember large words better than small words, even though memory for these words was equivalent on a standard test of recognition memory and subjective judgments. Critically, we also included tests that instructed participants to selectively search memory for either large or small words, thereby allowing different memorial expectations to contribute to performance. On these tests we found reduced false recognition when searching memory for large words relative to small words, such that the size illusion paradoxically affected accuracy measures (d' scores) in the absence of actual memory differences. Additional evidence for the role of illusory expectations was that (a) the accuracy effect was obtained only when participants searched memory for the aspect of the stimuli corresponding to illusory expectations (size instead of color) and (b) the accuracy effect was eliminated on a forced-choice test that prevented the influence of memorial expectations. These findings demonstrate the critical role of memorial expectations in the retrieval-monitoring process. 2012 APA, all rights reserved

  3. Guidance for deriving and presenting percentage study weights in meta-analysis of test accuracy studies.

    PubMed

    Burke, Danielle L; Ensor, Joie; Snell, Kym I E; van der Windt, Danielle; Riley, Richard D

    2018-06-01

    Percentage study weights in meta-analysis reveal the contribution of each study toward the overall summary results and are especially important when some studies are considered outliers or at high risk of bias. In meta-analyses of test accuracy reviews, such as a bivariate meta-analysis of sensitivity and specificity, the percentage study weights are not currently derived. Rather, the focus is on representing the precision of study estimates on receiver operating characteristic plots by scaling the points relative to the study sample size or to their standard error. In this article, we recommend that researchers should also provide the percentage study weights directly, and we propose a method to derive them based on a decomposition of Fisher information matrix. This method also generalises to a bivariate meta-regression so that percentage study weights can also be derived for estimates of study-level modifiers of test accuracy. Application is made to two meta-analyses examining test accuracy: one of ear temperature for diagnosis of fever in children and the other of positron emission tomography for diagnosis of Alzheimer's disease. These highlight that the percentage study weights provide important information that is otherwise hidden if the presentation only focuses on precision based on sample size or standard errors. Software code is provided for Stata, and we suggest that our proposed percentage weights should be routinely added on forest and receiver operating characteristic plots for sensitivity and specificity, to provide transparency of the contribution of each study toward the results. This has implications for the PRISMA-diagnostic test accuracy guidelines that are currently being produced. Copyright © 2017 John Wiley & Sons, Ltd.

  4. The STARD Statement for Reporting Diagnostic Accuracy Studies: Application to the History and Physical Examination

    PubMed Central

    Rennie, Drummond; Bossuyt, Patrick M. M.

    2008-01-01

    Summary Objective The Standards for Reporting of Diagnostic Accuracy (STARD) statement provided guidelines for investigators conducting diagnostic accuracy studies. We reviewed each item in the statement for its applicability to clinical examination diagnostic accuracy research, viewing each discrete aspect of the history and physical examination as a diagnostic test. Setting Nonsystematic review of the STARD statement. Interventions Two former STARD Group participants and 1 editor of a journal series on clinical examination research reviewed each STARD item. Suggested interpretations and comments were shared to develop consensus. Measurements and Main Results The STARD Statement applies generally well to clinical examination diagnostic accuracy studies. Three items are the most important for clinical examination diagnostic accuracy studies, and investigators should pay particular attention to their requirements: describe carefully the patient recruitment process, describe participant sampling and address if patients were from a consecutive series, and describe whether the clinicians were masked to the reference standard tests and whether the interpretation of the reference standard test was masked to the clinical examination components or overall clinical impression. The consideration of these and the other STARD items in clinical examination diagnostic research studies would improve the quality of investigations and strengthen conclusions reached by practicing clinicians. Conclusions The STARD statement provides a very useful framework for diagnostic accuracy studies. The group correctly anticipated that there would be nuances applicable to studies of the clinical examination. We offer guidance that should enhance their usefulness to investigators embarking on original studies of a patient’s history and physical examination. PMID:18347878

  5. Evidence synthesis to inform model-based cost-effectiveness evaluations of diagnostic tests: a methodological review of health technology assessments.

    PubMed

    Shinkins, Bethany; Yang, Yaling; Abel, Lucy; Fanshawe, Thomas R

    2017-04-14

    Evaluations of diagnostic tests are challenging because of the indirect nature of their impact on patient outcomes. Model-based health economic evaluations of tests allow different types of evidence from various sources to be incorporated and enable cost-effectiveness estimates to be made beyond the duration of available study data. To parameterize a health-economic model fully, all the ways a test impacts on patient health must be quantified, including but not limited to diagnostic test accuracy. We assessed all UK NIHR HTA reports published May 2009-July 2015. Reports were included if they evaluated a diagnostic test, included a model-based health economic evaluation and included a systematic review and meta-analysis of test accuracy. From each eligible report we extracted information on the following topics: 1) what evidence aside from test accuracy was searched for and synthesised, 2) which methods were used to synthesise test accuracy evidence and how did the results inform the economic model, 3) how/whether threshold effects were explored, 4) how the potential dependency between multiple tests in a pathway was accounted for, and 5) for evaluations of tests targeted at the primary care setting, how evidence from differing healthcare settings was incorporated. The bivariate or HSROC model was implemented in 20/22 reports that met all inclusion criteria. Test accuracy data for health economic modelling was obtained from meta-analyses completely in four reports, partially in fourteen reports and not at all in four reports. Only 2/7 reports that used a quantitative test gave clear threshold recommendations. All 22 reports explored the effect of uncertainty in accuracy parameters but most of those that used multiple tests did not allow for dependence between test results. 7/22 tests were potentially suitable for primary care but the majority found limited evidence on test accuracy in primary care settings. The uptake of appropriate meta-analysis methods for synthesising evidence on diagnostic test accuracy in UK NIHR HTAs has improved in recent years. Future research should focus on other evidence requirements for cost-effectiveness assessment, threshold effects for quantitative tests and the impact of multiple diagnostic tests.

  6. Investigating the encoding-retrieval match in recognition memory: effects of experimental design, specificity, and retention interval.

    PubMed

    Dewhurst, Stephen A; Knott, Lauren M

    2010-12-01

    Five experiments investigated the encoding-retrieval match in recognition memory by manipulating read and generate conditions at study and at test. Experiments 1A and 1B confirmed previous findings that reinstating encoding operations at test enhances recognition accuracy in a within-groups design but reduces recognition accuracy in a between-groups design. Experiment 2A showed that generating from anagrams at study and at test enhanced recognition accuracy even when study and test items were generated from different anagrams. Experiment 2B showed that switching from one generation task at study (e.g., anagram solution) to a different generation task at test (e.g., fragment completion) eliminated this recognition advantage. Experiment 3 showed that the recognition advantage found in Experiment 1A is reliably present up to 1 week after study. The findings are consistent with theories of memory that emphasize the importance of the match between encoding and retrieval operations.

  7. Performance of alternative strategies for primary cervical cancer screening in sub-Saharan Africa: systematic review and meta-analysis of diagnostic test accuracy studies

    PubMed Central

    Combescure, Christophe; Fokom-Defo, Victoire; Tebeu, Pierre Marie; Vassilakos, Pierre; Kengne, André Pascal; Petignat, Patrick

    2015-01-01

    Objective To assess and compare the accuracy of visual inspection with acetic acid (VIA), visual inspection with Lugol’s iodine (VILI), and human papillomavirus (HPV) testing as alternative standalone methods for primary cervical cancer screening in sub-Saharan Africa. Design Systematic review and meta-analysis of diagnostic test accuracy studies. Data sources Systematic searches of multiple databases including Medline, Embase, and Scopus for studies published between January 1994 and June 2014. Review methods Inclusion criteria for studies were: alternative methods to cytology used as a standalone test for primary screening; study population not at particular risk of cervical cancer (excluding studies focusing on HIV positive women or women with gynaecological symptoms); women screened by nurses; reference test (colposcopy and directed biopsies) performed at least in women with positive screening results. Two reviewers independently screened studies for eligibility and extracted data for inclusion, and evaluated study quality using the quality assessment of diagnostic accuracy studies 2 (QUADAS-2) checklist. Primary outcomes were absolute accuracy measures (sensitivity and specificity) of screening tests to detect cervical intraepithelial neoplasia grade 2 or worse (CIN2+). Results 15 studies of moderate quality were included (n=61 381 for VIA, n=46 435 for VILI, n=11 322 for HPV testing). Prevalence of CIN2+ did not vary by screening test and ranged from 2.3% (95% confidence interval 1.5% to 3.3%) in VILI studies to 4.9% (2.7% to 7.8%) in HPV testing studies. Positivity rates of VILI, VIA, and HPV testing were 16.5% (9.8% to 24.7%), 16.8% (11.0% to 23.6%), and 25.8% (17.4% to 35.3%), respectively. Pooled sensitivity was higher for VILI (95.1%; 90.1% to 97.7%) than VIA (82.4%; 76.3% to 87.3%) in studies where the reference test was performed in all women (P<0.001). Pooled specificity of VILI and VIA were similar (87.2% (78.1% to 92.8%) v 87.4% (77.1% to 93.4%); P=0.85). Pooled sensitivity and specificity were similar for HPV testing versus VIA (both P≥0.23) and versus VILI (both P≥0.16). Accuracy of VIA and VILI increased with sample size and time period. Conclusions For primary screening of cervical cancer in sub-Saharan Africa, VILI is a simple and affordable alternative to cytology that demonstrates higher sensitivity than VIA. Implementation studies are needed to assess the effect of these screening strategies on the incidence and outcomes of cervical cancer in the region. PMID:26142020

  8. Effects of disease severity distribution on the performance of quantitative diagnostic methods and proposal of a novel ‘V-plot’ methodology to display accuracy values

    PubMed Central

    Dehbi, Hakim-Moulay; Howard, James P; Shun-Shin, Matthew J; Sen, Sayan; Nijjer, Sukhjinder S; Mayet, Jamil; Davies, Justin E; Francis, Darrel P

    2018-01-01

    Background Diagnostic accuracy is widely accepted by researchers and clinicians as an optimal expression of a test’s performance. The aim of this study was to evaluate the effects of disease severity distribution on values of diagnostic accuracy as well as propose a sample-independent methodology to calculate and display accuracy of diagnostic tests. Methods and findings We evaluated the diagnostic relationship between two hypothetical methods to measure serum cholesterol (Cholrapid and Cholgold) by generating samples with statistical software and (1) keeping the numerical relationship between methods unchanged and (2) changing the distribution of cholesterol values. Metrics of categorical agreement were calculated (accuracy, sensitivity and specificity). Finally, a novel methodology to display and calculate accuracy values was presented (the V-plot of accuracies). Conclusion No single value of diagnostic accuracy can be used to describe the relationship between tests, as accuracy is a metric heavily affected by the underlying sample distribution. Our novel proposed methodology, the V-plot of accuracies, can be used as a sample-independent measure of a test performance against a reference gold standard. PMID:29387424

  9. Metacognitive Influences on Study Time Allocation in an Associative Recognition Task: An Analysis of Adult Age Differences

    PubMed Central

    Hines, Jarrod C.; Touron, Dayna R.; Hertzog, Christopher

    2009-01-01

    The current study evaluated a metacognitive account of study time allocation, which argues that metacognitive monitoring of recognition test accuracy and latency influences subsequent strategic control and regulation. We examined judgments of learning (JOLs), recognition test confidence judgments (CJs), and subjective response time (RT) judgments by younger and older adults in an associative recognition task involving two study-test phases, with self-paced study in phase 2. Multilevel regression analyses assessed the degree to which age and metacognitive variables predicted phase 2 study time independent of actual test accuracy and RT. Outcomes supported the metacognitive account – JOLs and CJs predicted study time independent of recognition accuracy. For older adults with errant RT judgments, subjective retrieval fluency influenced response confidence as well as (mediated through confidence) subsequent study time allocation. Older adults studied items longer which had been assigned lower CJs, suggesting no age deficit in using memory monitoring to control learning. PMID:19485662

  10. The Comparison of Accuracy Scores on the Paper and Pencil Testing vs. Computer-Based Testing

    ERIC Educational Resources Information Center

    Retnawati, Heri

    2015-01-01

    This study aimed to compare the accuracy of the test scores as results of Test of English Proficiency (TOEP) based on paper and pencil test (PPT) versus computer-based test (CBT). Using the participants' responses to the PPT documented from 2008-2010 and data of CBT TOEP documented in 2013-2014 on the sets of 1A, 2A, and 3A for the Listening and…

  11. Accuracy of a Classical Test Theory-Based Procedure for Estimating the Reliability of a Multistage Test. Research Report. ETS RR-17-02

    ERIC Educational Resources Information Center

    Kim, Sooyeon; Livingston, Samuel A.

    2017-01-01

    The purpose of this simulation study was to assess the accuracy of a classical test theory (CTT)-based procedure for estimating the alternate-forms reliability of scores on a multistage test (MST) having 3 stages. We generated item difficulty and discrimination parameters for 10 parallel, nonoverlapping forms of the complete 3-stage test and…

  12. Accuracy and User Performance Evaluation of a New, Wireless-enabled Blood Glucose Monitoring System That Links to a Smart Mobile Device.

    PubMed

    Bailey, Timothy S; Wallace, Jane F; Pardo, Scott; Warchal-Windham, Mary Ellen; Harrison, Bern; Morin, Robert; Christiansen, Mark

    2017-07-01

    The new Contour ® Plus ONE blood glucose monitoring system (BGMS) features an easy-to-use, wireless-enabled blood glucose meter that links to a smart mobile device via Bluetooth ® connectivity and can sync with the Contour ™ Diabetes app on a smartphone or tablet. The accuracy of the new BGMS was assessed in 2 studies according to ISO 15197:2013 criteria. In Study 1 (laboratory study), fingertip capillary blood samples from 100 subjects were tested in duplicate using 3 test strip lots. In Study 2 (clinical study), 134 subjects with type 1 or type 2 diabetes enrolled at 2 clinical sites. BGMS results and YSI analyzer (YSI) reference results were compared for fingertip blood obtained by untrained subjects' self-testing and for study staff-obtained fingertip, subject palm, and venous results. In Study 1, 99.0% (594/600) of combined results for all 3 test strip lots fulfilled ISO 15197:2013 Section 6.3 accuracy criteria. In Study 2, 99.2% (133/134) of subject-obtained capillary fingertip results, 99.2% (133/134) of study staff-obtained fingertip results, 99.2% (125/126) of subject-obtained palm results, and 100% (132/132) of study staff-obtained venous results met ISO 15197:2013 Section 8 accuracy criteria. Moreover, 95.5% (128/134) of subject-obtained fingertip self-test results were within ±10 mg/dl (±0.6 mmol/L) or ±10% of the YSI reference result. Questionnaire results showed that most subjects found the BGMS easy to use. The BGMS exceeded ISO 15197:2013 accuracy criteria both in the laboratory and in a clinical setting when used by untrained subjects with diabetes.

  13. Diagnostic Accuracy, Sensitivity, and Specificity of Executive Function Tests in Moderate Traumatic Brain Injury in Ghana.

    PubMed

    Adjorlolo, Samuel

    2018-06-01

    The sociocultural differences between Western and sub-Saharan African countries make it imperative to standardize neuropsychological tests in the latter. However, Western-normed tests are frequently administered in sub-Saharan Africa because of challenges hampering standardization efforts. Yet a salient topical issue in the cross-cultural neuropsychology literature relates to the utility of Western-normed neuropsychological tests in minority groups, non-Caucasians, and by extension Ghanaians. Consequently, this study investigates the diagnostic accuracy, sensitivity, and specificity of executive function (EF) tests (The Stroop Test, Trail Making Test, and Controlled Oral Word Association Test), and a Revised Quick Cognitive Screening Test (RQCST) in a sample of 50 patients diagnosed with moderate traumatic brain injury and 50 healthy controls in Ghana. The EF test scores showed good diagnostic accuracy, with area under the curve (AUC) values of the Trail Making Test scores ranging from .746 to .902. With respect to the Stroop Test scores, the AUC values ranged from .793 to .898, while Controlled Oral Word Association Test had AUC value of .787. The RQCST scores discriminated between the groups, with AUC values ranging from .674 to .912. The AUC values of composite EF score and a neuropsychological score created from EF and RQCST scores were .936 and. 942, respectively. Additionally, the Stroop Test, Trail Making Test, EF composite score, and RQCST scores showed good to excellent sensitivities and specificities. In general, this study has shown that commonly used EF tests in Western countries have diagnostic accuracy, sensitivity, and specificity when administered in Ghanaian samples. The findings and implications of the study are discussed.

  14. Adjusting for partial verification or workup bias in meta-analyses of diagnostic accuracy studies.

    PubMed

    de Groot, Joris A H; Dendukuri, Nandini; Janssen, Kristel J M; Reitsma, Johannes B; Brophy, James; Joseph, Lawrence; Bossuyt, Patrick M M; Moons, Karel G M

    2012-04-15

    A key requirement in the design of diagnostic accuracy studies is that all study participants receive both the test under evaluation and the reference standard test. For a variety of practical and ethical reasons, sometimes only a proportion of patients receive the reference standard, which can bias the accuracy estimates. Numerous methods have been described for correcting this partial verification bias or workup bias in individual studies. In this article, the authors describe a Bayesian method for obtaining adjusted results from a diagnostic meta-analysis when partial verification or workup bias is present in a subset of the primary studies. The method corrects for verification bias without having to exclude primary studies with verification bias, thus preserving the main advantages of a meta-analysis: increased precision and better generalizability. The results of this method are compared with the existing methods for dealing with verification bias in diagnostic meta-analyses. For illustration, the authors use empirical data from a systematic review of studies of the accuracy of the immunohistochemistry test for diagnosis of human epidermal growth factor receptor 2 status in breast cancer patients.

  15. Diagnostic Accuracy of Fall Risk Assessment Tools in People With Diabetic Peripheral Neuropathy

    PubMed Central

    Pohl, Patricia S.; Mahnken, Jonathan D.; Kluding, Patricia M.

    2012-01-01

    Background Diabetic peripheral neuropathy affects nearly half of individuals with diabetes and leads to increased fall risk. Evidence addressing fall risk assessment for these individuals is lacking. Objective The purpose of this study was to identify which of 4 functional mobility fall risk assessment tools best discriminates, in people with diabetic peripheral neuropathy, between recurrent “fallers” and those who are not recurrent fallers. Design A cross-sectional study was conducted. Setting The study was conducted in a medical research university setting. Participants The participants were a convenience sample of 36 individuals between 40 and 65 years of age with diabetic peripheral neuropathy. Measurements Fall history was assessed retrospectively and was the criterion standard. Fall risk was assessed using the Functional Reach Test, the Timed “Up & Go” Test, the Berg Balance Scale, and the Dynamic Gait Index. Sensitivity, specificity, positive and negative likelihood ratios, and overall diagnostic accuracy were calculated for each fall risk assessment tool. Receiver operating characteristic curves were used to estimate modified cutoff scores for each fall risk assessment tool; indexes then were recalculated. Results Ten of the 36 participants were classified as recurrent fallers. When traditional cutoff scores were used, the Dynamic Gait Index and Functional Reach Test demonstrated the highest sensitivity at only 30%; the Dynamic Gait Index also demonstrated the highest overall diagnostic accuracy. When modified cutoff scores were used, all tools demonstrated improved sensitivity (80% or 90%). Overall diagnostic accuracy improved for all tests except the Functional Reach Test; the Timed “Up & Go” Test demonstrated the highest diagnostic accuracy at 88.9%. Limitations The small sample size and retrospective fall history assessment were limitations of the study. Conclusions Modified cutoff scores improved diagnostic accuracy for 3 of 4 fall risk assessment tools when testing people with diabetic peripheral neuropathy. PMID:22836004

  16. Accuracy of urinary human papillomavirus testing for presence of cervical HPV: systematic review and meta-analysis

    PubMed Central

    Pathak, Neha; Dodds, Julie; Khan, Khalid

    2014-01-01

    Objective To determine the accuracy of testing for human papillomavirus (HPV) DNA in urine in detecting cervical HPV in sexually active women. Design Systematic review and meta-analysis. Data sources Searches of electronic databases from inception until December 2013, checks of reference lists, manual searches of recent issues of relevant journals, and contact with experts. Eligibility criteria Test accuracy studies in sexually active women that compared detection of urine HPV DNA with detection of cervical HPV DNA. Data extraction and synthesis Data relating to patient characteristics, study context, risk of bias, and test accuracy. 2×2 tables were constructed and synthesised by bivariate mixed effects meta-analysis. Results 16 articles reporting on 14 studies (1443 women) were eligible for meta-analysis. Most used commercial polymerase chain reaction methods on first void urine samples. Urine detection of any HPV had a pooled sensitivity of 87% (95% confidence interval 78% to 92%) and specificity of 94% (95% confidence interval 82% to 98%). Urine detection of high risk HPV had a pooled sensitivity of 77% (68% to 84%) and specificity of 88% (58% to 97%). Urine detection of HPV 16 and 18 had a pooled sensitivity of 73% (56% to 86%) and specificity of 98% (91% to 100%). Metaregression revealed an increase in sensitivity when urine samples were collected as first void compared with random or midstream (P=0.004). Limitations The major limitations of this review are the lack of a strictly uniform method for the detection of HPV in urine and the variation in accuracy between individual studies. Conclusions Testing urine for HPV seems to have good accuracy for the detection of cervical HPV, and testing first void urine samples is more accurate than random or midstream sampling. When cervical HPV detection is considered difficult in particular subgroups, urine testing should be regarded as an acceptable alternative. PMID:25232064

  17. Assessing clinical reasoning (ASCLIRE): Instrument development and validation.

    PubMed

    Kunina-Habenicht, Olga; Hautz, Wolf E; Knigge, Michel; Spies, Claudia; Ahlers, Olaf

    2015-12-01

    Clinical reasoning is an essential competency in medical education. This study aimed at developing and validating a test to assess diagnostic accuracy, collected information, and diagnostic decision time in clinical reasoning. A norm-referenced computer-based test for the assessment of clinical reasoning (ASCLIRE) was developed, integrating the entire clinical decision process. In a cross-sectional study participants were asked to choose as many diagnostic measures as they deemed necessary to diagnose the underlying disease of six different cases with acute or sub-acute dyspnea and provide a diagnosis. 283 students and 20 content experts participated. In addition to diagnostic accuracy, respective decision time and number of used relevant diagnostic measures were documented as distinct performance indicators. The empirical structure of the test was investigated using a structural equation modeling approach. Experts showed higher accuracy rates and lower decision times than students. In a cross-sectional comparison, the diagnostic accuracy of students improved with the year of study. Wrong diagnoses provided by our sample were comparable to wrong diagnoses in practice. We found an excellent fit for a model with three latent factors-diagnostic accuracy, decision time, and choice of relevant diagnostic information-with diagnostic accuracy showing no significant correlation with decision time. ASCLIRE considers decision time as an important performance indicator beneath diagnostic accuracy and provides evidence that clinical reasoning is a complex ability comprising diagnostic accuracy, decision time, and choice of relevant diagnostic information as three partly correlated but still distinct aspects.

  18. Towards improving diagnosis of memory loss in general practice: TIMeLi diagnostic test accuracy study protocol.

    PubMed

    Creavin, Sam T; Cullum, Sarah J; Haworth, Judy; Wye, Lesley; Bayer, Antony; Fish, Mark; Purdy, Sarah; Ben-Shlomo, Yoav

    2016-07-19

    People with cognitive problems, and their families, report distress and uncertainty whilst undergoing evaluation for dementia and perceive that traditional diagnostic evaluation in secondary care is insufficiently patient centred. The James Lind Alliance has prioritised research to investigate the role of primary care in supporting a more effective diagnostic pathway, and the topic is also of interest to health commissioners. However, there are very few studies that investigate the accuracy of diagnostic tests for dementia in primary care. We will conduct a prospective diagnostic test accuracy study to evaluate the accuracy of a range of simple tests for diagnosing all-cause-dementia in symptomatic people aged over 70 years who have consulted with their general practitioner (GP). We will invite eligible people to attend a research clinic where they will undergo a range of index tests that a GP could perform in the surgery and also be assessed by a specialist in memory disorders at the same appointment. Participating GPs will request neuroimaging and blood tests and otherwise manage patients in line with their usual clinical practice. The reference standard will be the consensus judgement of three experts (neurologist, psychiatrist and geriatrician) based on information from the specialist assessment, GP records and investigations, but not including items in the index test battery. The target condition will be all-cause dementia but we will also investigate diagnostic accuracy for sub-types where possible. We will use qualitative interviews with patients and focus groups with clinicians to help us understand the acceptability and feasibility of diagnosing dementia in primary care using the tests that we are investigating. Our results will help clinicians decide on which tests to perform in someone where there is concern about possible dementia and inform commissioning of diagnostic pathways.

  19. Bayesian estimation of sensitivity and specificity of a milk pregnancy-associated glycoprotein-based ELISA and of transrectal ultrasonographic exam for diagnosis of pregnancy at 28-45 days following breeding in dairy cows.

    PubMed

    Dufour, Simon; Durocher, Jean; Dubuc, Jocelyn; Dendukuri, Nandini; Hassan, Shereen; Buczinski, Sébastien

    2017-05-01

    Using a milk sample for pregnancy diagnosis in dairy cattle is extremely convenient due to the low technical inputs required for collection of biological materials. Determining accuracy of a novel pregnancy diagnostic test that relies on a milk sample is, however, difficult since no gold standard test is available for comparison. The objective of the current study was to estimate diagnostic accuracy of the milk PAG-based ELISA and of transrectal ultrasonographic (TUS) exam for determining pregnancy status of individual dairy cows using a methodology suited for test validation in the absence of gold standard. Secondary objectives were to evaluate whether test accuracy varies with cow's characteristics and to identify the optimal ELISA optical density threshold for PAG test interpretation. Cows (n=519) from 18 commercial dairies tested with both TUS and PAG between 28 and 45days following breeding were included in the study. Other covariates (number of days since breeding, parity, and daily milk production) hypothesized to affect TUS or PAG test accuracy were measured. A Bayesian hierarchical latent class model (LCM) methodology assuming conditional independence between tests was used to obtain estimates of tests' sensitivities (Se) and specificities (Sp), to evaluate impact of covariates on these, and to compute misclassification costs across a range of ELISA thresholds. Very little disagreement was observed between tests with only 23 cows yielding discordant results. Using the LCM model with non-informative priors for tests accuracy parameters, median (95% credibility intervals [CI]) TUS Se and Sp estimates of 0.96 (0.91, 1.00) and 0.99 (0.97, 1.0) were obtained. For the PAG test, median (95% CI) Se of 0.99 (0.98, 1.00) and Sp of 0.95 (0.89, 1.0) were observed. The impact of adjusting for conditional dependence between tests was negligible. Test accuracy of the PAG test varied slightly by parity number. When assuming false negative to false positive costs ratio≥3:1, the optimal ELISA optical density threshold allowing minimization of misclassification costs was 0.25. In conclusion, both TUS and PAG showed excellent accuracy for pregnancy diagnosis in dairy cows. When using the PAG test, a threshold of 0.25 could be used for test interpretation. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Diagnostic accuracy of physical examination for anterior knee instability: a systematic review.

    PubMed

    Leblanc, Marie-Claude; Kowalczuk, Marcin; Andruszkiewicz, Nicole; Simunovic, Nicole; Farrokhyar, Forough; Turnbull, Travis Lee; Debski, Richard E; Ayeni, Olufemi R

    2015-10-01

    Determining diagnostic accuracy of Lachman, pivot shift and anterior drawer tests versus gold standard diagnosis (magnetic resonance imaging or arthroscopy) for anterior cruciate ligament (ACL) insufficiency cases. Secondarily, evaluating effects of: chronicity, partial rupture, awake versus anaesthetized evaluation. Searching MEDLINE, EMBASE and PubMed identified studies on diagnostic accuracy for ACL insufficiency. Studies identification and data extraction were performed in duplicate. Quality assessment used QUADAS tool, and statistical analyses were completed for pooled sensitivity and specificity. Eight studies were included. Given insufficient data, pooled analysis was only possible for sensitivity on Lachman and pivot shift test. During awake evaluation, sensitivity for the Lachman test was 89 % (95 % CI 0.76, 0.98) for all rupture types, 96 % (95 % CI 0.90, 1.00) for complete ruptures and 68 % (95 % CI 0.25, 0.98) for partial ruptures. For pivot shift in awake evaluation, results were 79 % (95 % CI 0.63, 0.91) for all rupture types, 86 % (95 % CI 0.68, 0.99) for complete ruptures and 67 % (95 % CI 0.47, 0.83) for partial ruptures. Decreased sensitivity of Lachman and pivot shift tests for partial rupture cases and for awake patients raised suspicions regarding the accuracy of these tests for diagnosis of ACL insufficiency. This may lead to further research aiming to improve the understanding of the true accuracy of these physical diagnostic tests and increase the reliability of clinical investigation for this pathology. IV.

  1. Differential Effects of Intelligence, Perceptual Speed and Age on Growth in Attentional Speed and Accuracy

    ERIC Educational Resources Information Center

    Goldhammer, Frank; Rauch, Wolfgang A.; Schweizer, Karl; Moosbrugger, Helfried

    2010-01-01

    The study investigates the effects of intelligence, perceptual speed and age on intraindividual growth in attentional speed and attentional accuracy over the course of a 6-minute testing session. A sample of 193 subjects completed the Advanced Progressive Matrices and the Vienna Matrices Test representing intelligence, the tests Alertness and…

  2. Systematic Review of Health Economic Evaluations of Diagnostic Tests in Brazil: How accurate are the results?

    PubMed

    Oliveira, Maria Regina Fernandes; Leandro, Roseli; Decimoni, Tassia Cristina; Rozman, Luciana Martins; Novaes, Hillegonda Maria Dutilh; De Soárez, Patrícia Coelho

    2017-08-01

    The aim of this study is to identify and characterize the health economic evaluations (HEEs) of diagnostic tests conducted in Brazil, in terms of their adherence to international guidelines for reporting economic studies and specific questions in test accuracy reports. We systematically searched multiple databases, selecting partial and full HEEs of diagnostic tests, published between 1980 and 2013. Two independent reviewers screened articles for relevance and extracted the data. We performed a qualitative narrative synthesis. Forty-three articles were reviewed. The most frequently studied diagnostic tests were laboratory tests (37.2%) and imaging tests (32.6%). Most were non-invasive tests (51.2%) and were performed in the adult population (48.8%). The intended purposes of the technologies evaluated were mostly diagnostic (69.8%), but diagnosis and treatment and screening, diagnosis, and treatment accounted for 25.6% and 4.7%, respectively. Of the reviewed studies, 12.5% described the methods used to estimate the quantities of resources, 33.3% reported the discount rate applied, and 29.2% listed the type of sensitivity analysis performed. Among the 12 cost-effectiveness analyses, only two studies (17%) referred to the application of formal methods to check the quality of the accuracy studies that provided support for the economic model. The existing Brazilian literature on the HEEs of diagnostic tests exhibited reasonably good performance. However, the following points still require improvement: 1) the methods used to estimate resource quantities and unit costs, 2) the discount rate, 3) descriptions of sensitivity analysis methods, 4) reporting of conflicts of interest, 5) evaluations of the quality of the accuracy studies considered in the cost-effectiveness models, and 6) the incorporation of accuracy measures into sensitivity analyses.

  3. Executive Processes, Memory Accuracy, and Memory Monitoring: An Aging and Individual Difference Analysis

    ERIC Educational Resources Information Center

    Rhodes, M.G.; Kelley, C.M.

    2005-01-01

    The current study examined the neuropsychological correlates of memory accuracy in older and younger adults. Participants were tested in a memory monitoring paradigm developed by Koriat and Goldsmith (1996), which permits separate assessments of the accuracy of responses generated during retrieval and the accuracy of monitoring those responses.…

  4. A Method for Assessing the Accuracy of a Photogrammetry System for Precision Deployable Structures

    NASA Technical Reports Server (NTRS)

    Moore, Ashley

    2005-01-01

    The measurement techniques used to validate analytical models of large deployable structures are an integral Part of the technology development process and must be precise and accurate. Photogrammetry and videogrammetry are viable, accurate, and unobtrusive methods for measuring such large Structures. Photogrammetry uses Software to determine the three-dimensional position of a target using camera images. Videogrammetry is based on the same principle, except a series of timed images are analyzed. This work addresses the accuracy of a digital photogrammetry system used for measurement of large, deployable space structures at JPL. First, photogrammetry tests are performed on a precision space truss test article, and the images are processed using Photomodeler software. The accuracy of the Photomodeler results is determined through, comparison with measurements of the test article taken by an external testing group using the VSTARS photogrammetry system. These two measurements are then compared with Australis photogrammetry software that simulates a measurement test to predict its accuracy. The software is then used to study how particular factors, such as camera resolution and placement, affect the system accuracy to help design the setup for the videogrammetry system that will offer the highest level of accuracy for measurement of deploying structures.

  5. Accuracy of simple urine tests for diagnosis of urinary tract infections in low-risk pregnant women.

    PubMed

    Feitosa, Danielle Cristina Alves; da Silva, Márcia Guimarães; de Lima Parada, Cristina Maria Garcia

    2009-01-01

    Anatomic and physiological alterations during pregnancy predispose pregnant women to urinary tract infections (UTI). This study aimed to identify the accuracy of the simple urine test for UTI diagnosis in low-risk pregnant women. Diagnostic test performance was conducted in Botucatu, SP, involving 230 pregnant women, between 2006 and 2008. Results showed 10% UTI prevalence. Sensitivity, specificity and accuracy of the simple urine test were 95.6%, 63.3% and 66.5%, respectively, in relation to UTI diagnoses. The analysis of positive (PPV) and negative (NPV) predictive values showed that, when a regular simple urine test was performed, the chance of UTI occurrence was small (NPV 99.2%). In view of an altered result for such a test, the possibility of UTI existence was small (PPV 22.4%). It was concluded that the accuracy of the simple urine test as a diagnostic means for UTI was low, and that performing a urine culture is essential for appropriate diagnosis.

  6. Diagnostic accuracy of tuberculous lymphadenitis fine needle aspiration biopsy confirmed by PCR as gold standard

    NASA Astrophysics Data System (ADS)

    DSuryadi; Delyuzar; Soekimin

    2018-03-01

    Indonesia is the second country with the TB (tuberculosis) burden in the world. Improvement in controlling TB and reducing the complications can accelerate early diagnosis and correct treatment. PCR test is a gold standard. However, it is quite expensive for routine diagnosis. Therefore, an accurate and cheaper diagnostic method such as fine needle aspiration biopsy is needed. The study aimsto determine the accuracy of fine needle aspiration biopsy cytology in the diagnosis of tuberculous lymphadenitis. A cross-sectional analytic study was conducted to the samples from patients suspected with tuberculous lymphadenitis. The fine needle aspiration biopsy (FNAB)test was performed and confirmed by PCR test.There is a comparison to the sensitivity, specificity, accuracy, positive predictive value and negative predictive value of both methods. Sensitivity (92.50%), specificity (96.49%), accuracy (94.85%), positive predictive value (94.87%) and negative predictive value (94.83%) were in FNAB test compared to gold standard. We concluded that fine needle aspiration biopsy is a recommendation for a cheaper and accurate diagnostic test for tuberculous lymphadenitis diagnosis.

  7. Dose accuracy of a durable insulin pen with memory function, before and after simulated lifetime use and under stress conditions.

    PubMed

    Xue, Ligang; Mikkelsen, Kristian Handberg

    2013-03-01

    The objective of this study was to assess the dose accuracy of NovoPen® 5 in delivering low, medium and high doses of insulin before and after simulated lifetime use. A secondary objective was to evaluate the durability of the pen and its memory function under various stress conditions designed to simulate conditions that may be encountered in everyday use of an insulin pen. All testing was conducted according to International Organization for Standardization guideline 11608-1, 2000 for pen injectors. Dose accuracy was measured for the delivery of 1 unit (U) (10 mg), 30 U (300 mg) and 60 U (600 mg) test medium in standard, cool and hot conditions and before and after simulated lifetime use. Dose accuracy was also tested after preconditioning in dry heat storage; cold storage; damp cyclical heat; shock, bump and vibration; free fall and after electrostatic charge and radiated field test. Memory function was tested under all temperature and physical conditions. NovoPen 5 maintained dosing accuracy and memory function at minimum, medium and maximum doses in standard, cool and hot conditions, stress tests and simulated lifetime use. The pens remained intact and retained dosing accuracy and a working memory function at all doses after exposure to variations in temperature and after physical challenge. NovoPen 5 was accurate at all doses tested and under various functionality tests. Its durable design ensured that the dose accuracy and memory function were retained under conditions of stress likely to be encountered in everyday use.

  8. Meta-analysis of diagnostic accuracy studies in mental health

    PubMed Central

    Takwoingi, Yemisi; Riley, Richard D; Deeks, Jonathan J

    2015-01-01

    Objectives To explain methods for data synthesis of evidence from diagnostic test accuracy (DTA) studies, and to illustrate different types of analyses that may be performed in a DTA systematic review. Methods We described properties of meta-analytic methods for quantitative synthesis of evidence. We used a DTA review comparing the accuracy of three screening questionnaires for bipolar disorder to illustrate application of the methods for each type of analysis. Results The discriminatory ability of a test is commonly expressed in terms of sensitivity (proportion of those with the condition who test positive) and specificity (proportion of those without the condition who test negative). There is a trade-off between sensitivity and specificity, as an increasing threshold for defining test positivity will decrease sensitivity and increase specificity. Methods recommended for meta-analysis of DTA studies --such as the bivariate or hierarchical summary receiver operating characteristic (HSROC) model --jointly summarise sensitivity and specificity while taking into account this threshold effect, as well as allowing for between study differences in test performance beyond what would be expected by chance. The bivariate model focuses on estimation of a summary sensitivity and specificity at a common threshold while the HSROC model focuses on the estimation of a summary curve from studies that have used different thresholds. Conclusions Meta-analyses of diagnostic accuracy studies can provide answers to important clinical questions. We hope this article will provide clinicians with sufficient understanding of the terminology and methods to aid interpretation of systematic reviews and facilitate better patient care. PMID:26446042

  9. Screening for Dyslexia in French-Speaking University Students: An Evaluation of the Detection Accuracy of the Alouette Test.

    PubMed

    Cavalli, Eddy; Colé, Pascale; Leloup, Gilles; Poracchia-George, Florence; Sprenger-Charolles, Liliane; El Ahmadi, Abdessadek

    Developmental dyslexia is a lifelong impairment affecting 5% to 10% of the population. In French-speaking countries, although a number of standardized tests for dyslexia in children are available, tools suitable to screen for dyslexia in adults are lacking. In this study, we administered the Alouette reading test to a normative sample of 164 French university students without dyslexia and a validation sample of 83 students with dyslexia. The Alouette reading test is designed to screen for dyslexia in children, since it taps skills that are typically deficient in dyslexia (i.e., phonological skills). However, the test's psychometric properties have not previously been available, and it is not standardized for adults. The results showed that, on the Alouette test, dyslexic readers were impaired on measures of accuracy, speed, and efficiency (accuracy/reading time). We also found significant correlations between the Alouette reading efficiency and phonological efficiency scores. Finally, in terms of the Alouette test, speed-accuracy trade-offs were found in both groups, and optimal cutoff scores were determined with receiver operator characteristic curves analysis, yielding excellent discriminatory power, with 83.1% sensitivity and 100% specificity for reading efficiency. Thus, this study supports the Alouette test as a sensitive and specific screening tool for adults with dyslexia.

  10. Overinterpretation and misreporting of diagnostic accuracy studies: evidence of "spin".

    PubMed

    Ochodo, Eleanor A; de Haan, Margriet C; Reitsma, Johannes B; Hooft, Lotty; Bossuyt, Patrick M; Leeflang, Mariska M G

    2013-05-01

    To estimate the frequency of distorted presentation and overinterpretation of results in diagnostic accuracy studies. MEDLINE was searched for diagnostic accuracy studies published between January and June 2010 in journals with an impact factor of 4 or higher. Articles included were primary studies of the accuracy of one or more tests in which the results were compared with a clinical reference standard. Two authors scored each article independently by using a pretested data-extraction form to identify actual overinterpretation and practices that facilitate overinterpretation, such as incomplete reporting of study methods or the use of inappropriate methods (potential overinterpretation). The frequency of overinterpretation was estimated in all studies and in a subgroup of imaging studies. Of the 126 articles, 39 (31%; 95% confidence interval [CI]: 23, 39) contained a form of actual overinterpretation, including 29 (23%; 95% CI: 16, 30) with an overly optimistic abstract, 10 (8%; 96% CI: 3%, 13%) with a discrepancy between the study aim and conclusion, and eight with conclusions based on selected subgroups. In our analysis of potential overinterpretation, authors of 89% (95% CI: 83%, 94%) of the studies did not include a sample size calculation, 88% (95% CI: 82%, 94%) did not state a test hypothesis, and 57% (95% CI: 48%, 66%) did not report CIs of accuracy measurements. In 43% (95% CI: 34%, 52%) of studies, authors were unclear about the intended role of the test, and in 3% (95% CI: 0%, 6%) they used inappropriate statistical tests. A subgroup analysis of imaging studies showed 16 (30%; 95% CI: 17%, 43%) and 53 (100%; 95% CI: 92%, 100%) contained forms of actual and potential overinterpretation, respectively. Overinterpretation and misreporting of results in diagnostic accuracy studies is frequent in journals with high impact factors. http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.12120527/-/DC1. © RSNA, 2013.

  11. German translation, cross-cultural adaptation and diagnostic test accuracy of three frailty screening tools : PRISMA-7, FRAIL scale and Groningen Frailty Indicator.

    PubMed

    Braun, Tobias; Grüneberg, Christian; Thiel, Christian

    2018-04-01

    Routine screening for frailty could be used to timely identify older people with increased vulnerability und corresponding medical needs. The aim of this study was the translation and cross-cultural adaptation of the PRISMA-7 questionnaire, the FRAIL scale and the Groningen Frailty Indicator (GFI) into the German language as well as a preliminary analysis of the diagnostic test accuracy of these instruments used to screen for frailty. A diagnostic cross-sectional study was performed. The instrument translation into German followed a standardized process. Prefinal versions were clinically tested on older adults who gave structured in-depth feedback on the scales in order to compile a final revision of the German language scale versions. For the analysis of diagnostic test accuracy (criterion validity), PRISMA-7, FRAIL scale and GFI were considered the index tests. Two reference tests were applied to assess frailty, either based on Fried's model of a Physical Frailty Phenotype or on the model of deficit accumulation, expressed in a Frailty Index. Prefinal versions of the German translations of each instrument were produced and completed by 52 older participants (mean age: 73 ± 6 years). Some minor issues concerning comprehensibility and semantics of the scales were identified and resolved. Using the Physical Frailty Phenotype (frailty prevalence: 4%) criteria as a reference standard, the accuracy of the instruments was excellent (area under the curve AUC >0.90). Taking the Frailty Index (frailty prevalence: 23%) as the reference standard, the accuracy was good (AUC between 0.73 and 0.88). German language versions of PRISMA-7, FRAIL scale and GFI have been established and preliminary results indicate sufficient diagnostic test accuracy that needs to be further established.

  12. Sensitivity, Specificity, Predictive Values, and Accuracy of Three Diagnostic Tests to Predict Inferior Alveolar Nerve Blockade Failure in Symptomatic Irreversible Pulpitis

    PubMed Central

    Rodríguez-Wong, Laura; Noguera-González, Danny; Esparza-Villalpando, Vicente; Montero-Aguilar, Mauricio

    2017-01-01

    Introduction The inferior alveolar nerve block (IANB) is the most common anesthetic technique used on mandibular teeth during root canal treatment. Its success in the presence of preoperative inflammation is still controversial. The aim of this study was to evaluate the sensitivity, specificity, predictive values, and accuracy of three diagnostic tests used to predict IANB failure in symptomatic irreversible pulpitis (SIP). Methodology A cross-sectional study was carried out on the mandibular molars of 53 patients with SIP. All patients received a single cartridge of mepivacaine 2% with 1 : 100000 epinephrine using the IANB technique. Three diagnostic clinical tests were performed to detect anesthetic failure. Anesthetic failure was defined as a positive painful response to any of the three tests. Sensitivity, specificity, predictive values, accuracy, and ROC curves were calculated and compared and significant differences were analyzed. Results IANB failure was determined in 71.7% of the patients. The sensitivity scores for the three tests (lip numbness, the cold stimuli test, and responsiveness during endodontic access) were 0.03, 0.35, and 0.55, respectively, and the specificity score was determined as 1 for all of the tests. Clinically, none of the evaluated tests demonstrated a high enough accuracy (0.30, 0.53, and 0.68 for lip numbness, the cold stimuli test, and responsiveness during endodontic access, resp.). A comparison of the areas under the curve in the ROC analyses showed statistically significant differences between the three tests (p < 0.05). Conclusion None of the analyzed tests demonstrated a high enough accuracy to be considered a reliable diagnostic tool for the prediction of anesthetic failure. PMID:28694714

  13. Judgments of Learning are Influenced by Multiple Cues In Addition to Memory for Past Test Accuracy.

    PubMed

    Hertzog, Christopher; Hines, Jarrod C; Touron, Dayna R

    When people try to learn new information (e.g., in a school setting), they often have multiple opportunities to study the material. One of the most important things to know is whether people adjust their study behavior on the basis of past success so as to increase their overall level of learning (for example, by emphasizing information they have not yet learned). Monitoring their learning is a key part of being able to make those kinds of adjustments. We used a recognition memory task to replicate prior research showing that memory for past test outcomes influences later monitoring, as measured by judgments of learning (JOLs; confidence that the material has been learned), but also to show that subjective confidence in whether the test answer and the amount of time taken to restudy the items also have independent effects on JOLs. We also show that there are individual differences in the effects of test accuracy and test confidence on JOLs, showing that some but not all people use past test experiences to guide monitoring of their new learning. Monitoring learning is therefore a complex process of considering multiple cues, and some people attend to those cues more effectively than others. Improving the quality of monitoring performance and learning could lead to better study behaviors and better learning. An individual's memory of past test performance (MPT) is often cited as the primary cue for judgments of learning (JOLs) following test experience during multi-trial learning tasks (Finn & Metcalfe, 2007; 2008). We used an associative recognition task to evaluate MPT-related phenomena, because performance monitoring, as measured by recognition test confidence judgments (CJs), is fallible and varies in accuracy across persons. The current study used multilevel regression models to show the simultaneous and independent influences of multiple cues on Trial 2 JOLs, in addition to performance accuracy (the typical measure of MPT in cued-recall experiments). These cues include recognition CJs, perceived recognition fluency, and Trial 2 study time allocation (an index of reprocessing fluency). Our results expand the scope of MPT-related phenomena in recognition memory testing to show independent effects of recognition test accuracy and CJs on second-trial JOLs, while also demonstrating individual differences in the effects of these cues on JOLs (as manifested in significant random effects for those regression effects in the model). The effect of study time on second-trial JOLs controlling on other variables, including Trial 1 recognition memory accuracy, also demonstrates that second-trial encoding behavior influence JOLs in addition to MPT.

  14. Diagnostic accuracy of nucleic acid amplification tests (NAATs) in urine for genitourinary tuberculosis: a systematic review and meta-analysis.

    PubMed

    Altez-Fernandez, Carlos; Ortiz, Victor; Mirzazadeh, Majid; Zegarra, Luis; Seas, Carlos; Ugarte-Gil, Cesar

    2017-06-05

    Genitourinary tuberculosis is the third most common form of extrapulmonary tuberculosis. Diagnosis is difficult because of unspecific clinical manifestations and low accuracy of conventional tests. Unfortunately, the delayed diagnosis impacts the urinary tract severely. Nucleic acid amplification tests yield fast results, and among these, new technologies can also detect drug resistance. There is lack of consensus regarding the use of these tests in genitourinary tuberculosis; we therefore aimed to assess the accuracy of nucleic acid amplification tests in the diagnosis of genitourinary tuberculosis and to evaluate the heterogeneity between studies. We did a systematic review and meta-analysis of research articles comparing the accuracy of a reference standard and a nucleic acid amplification test for diagnosis of urinary tract tuberculosis. We searched Medline, EMBASE, Web of Science, LILACS, Cochrane Library, and Scopus for articles published between Jan 1, 1990, and Apr 14, 2016. Two investigators identified eligible articles and extracted data for individual study sites. We analyzed data in groups with the same index test. Then, we generated pooled summary estimates (95% CIs) for sensitivity and specificity by use of random-effects meta-analysis when studies were not heterogeneous. We identified eleven relevant studies from ten articles, giving information on PCR, LCR and Xpert MTB/RIF tests. All PCR studies were "in-house" tests, with different gene targets and had several quality concerns therefore we did not proceed with a pooled analysis. Only one study used LCR. Xpert studies were of good quality and not heterogeneous, pooled sensitivity was 0·87 (0·66-0·96) and specificity was 0·91 (0·84-0·95). PCR studies were highly heterogeneous. Among Xpert MTB/RIF studies, specificity was favorable with an acceptable confidence interval, however new studies can update meta-analysis and get more precise estimates. Further high-quality studies are urgently needed to improve diagnosis of genitourinary tuberculosis. PROSPERO CRD42016039020.

  15. Verification and classification bias interactions in diagnostic test accuracy studies for fine-needle aspiration biopsy.

    PubMed

    Schmidt, Robert L; Walker, Brandon S; Cohen, Michael B

    2015-03-01

    Reliable estimates of accuracy are important for any diagnostic test. Diagnostic accuracy studies are subject to unique sources of bias. Verification bias and classification bias are 2 sources of bias that commonly occur in diagnostic accuracy studies. Statistical methods are available to estimate the impact of these sources of bias when they occur alone. The impact of interactions when these types of bias occur together has not been investigated. We developed mathematical relationships to show the combined effect of verification bias and classification bias. A wide range of case scenarios were generated to assess the impact of bias components and interactions on total bias. Interactions between verification bias and classification bias caused overestimation of sensitivity and underestimation of specificity. Interactions had more effect on sensitivity than specificity. Sensitivity was overestimated by at least 7% in approximately 6% of the tested scenarios. Specificity was underestimated by at least 7% in less than 0.1% of the scenarios. Interactions between verification bias and classification bias create distortions in accuracy estimates that are greater than would be predicted from each source of bias acting independently. © 2014 American Cancer Society.

  16. Research on Horizontal Accuracy Method of High Spatial Resolution Remotely Sensed Orthophoto Image

    NASA Astrophysics Data System (ADS)

    Xu, Y. M.; Zhang, J. X.; Yu, F.; Dong, S.

    2018-04-01

    At present, in the inspection and acceptance of high spatial resolution remotly sensed orthophoto image, the horizontal accuracy detection is testing and evaluating the accuracy of images, which mostly based on a set of testing points with the same accuracy and reliability. However, it is difficult to get a set of testing points with the same accuracy and reliability in the areas where the field measurement is difficult and the reference data with high accuracy is not enough. So it is difficult to test and evaluate the horizontal accuracy of the orthophoto image. The uncertainty of the horizontal accuracy has become a bottleneck for the application of satellite borne high-resolution remote sensing image and the scope of service expansion. Therefore, this paper proposes a new method to test the horizontal accuracy of orthophoto image. This method using the testing points with different accuracy and reliability. These points' source is high accuracy reference data and field measurement. The new method solves the horizontal accuracy detection of the orthophoto image in the difficult areas and provides the basis for providing reliable orthophoto images to the users.

  17. Sensitivity to Spatiotemporal Percepts Predicts the Perception of Emotion

    PubMed Central

    Castro, Vanessa L.; Boone, R. Thomas

    2015-01-01

    The present studies examined how sensitivity to spatiotemporal percepts such as rhythm, angularity, configuration, and force predicts accuracy in perceiving emotion. In Study 1, participants (N = 99) completed a nonverbal test battery consisting of three nonverbal emotion perception tests and two perceptual sensitivity tasks assessing rhythm sensitivity and angularity sensitivity. Study 2 (N = 101) extended the findings of Study 1 with the addition of a fourth nonverbal test, a third configural sensitivity task, and a fourth force sensitivity task. Regression analyses across both studies revealed partial support for the association between perceptual sensitivity to spatiotemporal percepts and greater emotion perception accuracy. Results indicate that accuracy in perceiving emotions may be predicted by sensitivity to specific percepts embedded within channel- and emotion-specific displays. The significance of such research lies in the understanding of how individuals acquire emotion perception skill and the processes by which distinct features of percepts are related to the perception of emotion. PMID:26339111

  18. Clinical accuracy of point-of-care urine culture in general practice.

    PubMed

    Holm, Anne; Cordoba, Gloria; Sørensen, Tina Møller; Jessen, Lisbeth Rem; Frimodt-Møller, Niels; Siersma, Volkert; Bjerrum, Lars

    2017-06-01

    To assess the clinical accuracy (sensitivity (SEN), specificity (SPE), positive predictive value and negative predictive value) of two point-of-care (POC) urine culture tests for the identification of urinary tract infection (UTI) in general practice. Prospective diagnostic accuracy study comparing two index tests (Flexicult™ SSI-Urinary Kit or ID Flexicult™) with a reference standard (urine culture performed in the microbiological department). General practice in the Copenhagen area patients. Adult female patients consulting their general practitioner with suspected uncomplicated, symptomatic UTI. (1) Overall accuracy of POC urine culture in general practice. (2) Individual accuracy of each of the two POC tests in this study. (3) Accuracy of POC urine culture in general practice with enterococci excluded, since enterococci are known to multiply in boric acid used for transportation for the reference standard. (4) Accuracy based on expert reading of photographs of POC urine cultures performed in general practice. Standard culture performed in the microbiological department was used as reference standard for all four measures. Twenty general practices recruited 341 patients with suspected uncomplicated UTI. The overall agreement between index test and reference was 0.76 (CI: 0.71-0.80), SEN 0.88 (CI: 0.83-0.92) and SPE 0.55 (CI: 0.46-0.64). The two POC tests produced similar results individually. Overall agreement with enterococci excluded was 0.82 (0.77-0.86) and agreement between expert readings of photographs and reference results was 0.81 (CI: 0.76-0.85). POC culture used in general practice has high SEN but low SPE. Low SPE could be due to both misinterpretation in general practice and an imperfect reference standard. Registration number: ClinicalTrials.gov NCT02323087.

  19. Social Eavesdropping: Can You Hear the Emotionality in a "Hello" That Is Not Meant for You?

    PubMed

    Karthikeyan, Sethu; Ramachandra, Vijayachandra

    2017-01-01

    The study examined third-party listeners' ability to detect the Hellos spoken to prevalidated happy, neutral, and sad facial expressions. The average detection accuracies from the happy and sad (HS), happy and neutral (HN), and sad and neutral (SN) listening tests followed the average vocal pitch differences between the two sets of Hellos in each of the tests; HS and HN detection accuracies were above chance reflecting the significant pitch differences between the respective Hellos. The SN detection accuracy was at chance reflecting the lack of pitch difference between sad and neutral Hellos. As expected, the SN detection accuracy positively correlated with theory of mind; participating in these tests has been likened to the act of eavesdropping, which has been discussed from an evolutionary perspective. An unexpected negative correlation between the HS detection accuracy and the empathy quotient has been discussed with respect to autism research on empathy and pitch discrimination.

  20. Social class, contextualism, and empathic accuracy.

    PubMed

    Kraus, Michael W; Côté, Stéphane; Keltner, Dacher

    2010-11-01

    Recent research suggests that lower-class individuals favor explanations of personal and political outcomes that are oriented to features of the external environment. We extended this work by testing the hypothesis that, as a result, individuals of a lower social class are more empathically accurate in judging the emotions of other people. In three studies, lower-class individuals (compared with upper-class individuals) received higher scores on a test of empathic accuracy (Study 1), judged the emotions of an interaction partner more accurately (Study 2), and made more accurate inferences about emotion from static images of muscle movements in the eyes (Study 3). Moreover, the association between social class and empathic accuracy was explained by the tendency for lower-class individuals to explain social events in terms of features of the external environment. The implications of class-based patterns in empathic accuracy for well-being and relationship outcomes are discussed.

  1. Diagnostic accuracy of the Thessaly test, standardised clinical history and other clinical examination tests (Apley's, McMurray's and joint line tenderness) for meniscal tears in comparison with magnetic resonance imaging diagnosis.

    PubMed

    Blyth, Mark; Anthony, Iain; Francq, Bernard; Brooksbank, Katriona; Downie, Paul; Powell, Andrew; Jones, Bryn; MacLean, Angus; McConnachie, Alex; Norrie, John

    2015-08-01

    Reliable non-invasive diagnosis of meniscal tears is difficult. Magnetic resonance imaging (MRI) is often used but is expensive and incidental findings are problematic. There are a number of physical examination tests for the diagnosis of meniscal tears that are simple, cheap and non-invasive. To determine the diagnostic accuracy of the Thessaly test and to determine if the Thessaly test (alone or in combination with other physical tests) can obviate the need for further investigation by MRI or arthroscopy for patients with a suspected meniscal tear. Single-centre prospective diagnostic accuracy study. Although the study was performed in a secondary care setting, it was designed to replicate the results that would have been achieved in a primary care setting. Two cohorts of patients were recruited: patients with knee pathology (n = 292) and a control cohort with no knee pathology (n = 75). Sensitivity, specificity and diagnostic accuracy of the Thessaly test in determining the presence of meniscal tears. Participants were assessed by both a primary care clinician and a musculoskeletal clinician. Both clinicians performed the Thessaly test, McMurray's test, Apley's test, joint line tenderness test and took a standardised clinical history from the patient. The Thessaly test had a sensitivity of 0.66, a specificity of 0.39 and a diagnostic accuracy of 54% when utilised by primary care clinicians. This compared with a sensitivity of 0.62, a specificity of 0.55 and diagnostic accuracy of 59% when used by musculoskeletal clinicians. The diagnostics accuracy of the other tests when used by primary care clinicians was 54% for McMurray's test, 53% for Apley's test, 54% for the joint line tenderness test and 55% for clinical history. For primary care clinicians, age and past history of osteoarthritis were both significant predictors of MRI diagnosis of meniscal tears. For musculoskeletal clinicians age and a positive diagnosis of meniscal tears on clinical history taking were significant predictors of MRI diagnosis. No physical tests were significant predictors of MRI diagnosis in our multivariate models. The specificity of MRI diagnosis was tested in subgroup of patients who went on to have a knee arthroscopy and was found to be low [0.53 (95% confidence interval 0.28 to 0.77)], although the sensitivity was 1.0. The Thessaly test was no better at diagnosing meniscal tears than other established physical tests. The sensitivity, specificity and diagnostic accuracy of all physical tests was too low to be of routine clinical value as an alternative to MRI. Caution needs to be exercised in the indiscriminate use of MRI scanning in the identification of meniscal tears in the diagnosis of the painful knee, due to the low specificity seen in the presence of concomitant knee pathology. Further research is required to determine the true diagnostic accuracy and cost-effectiveness of MRI for the detection of meniscal tears. Current Controlled Trial ISRCTN43527822. The National Institute for Health Research Health Technology Assessment programme.

  2. ROC curves in clinical chemistry: uses, misuses, and possible solutions.

    PubMed

    Obuchowski, Nancy A; Lieber, Michael L; Wians, Frank H

    2004-07-01

    ROC curves have become the standard for describing and comparing the accuracy of diagnostic tests. Not surprisingly, ROC curves are used often by clinical chemists. Our aims were to observe how the accuracy of clinical laboratory diagnostic tests is assessed, compared, and reported in the literature; to identify common problems with the use of ROC curves; and to offer some possible solutions. We reviewed every original work using ROC curves and published in Clinical Chemistry in 2001 or 2002. For each article we recorded phase of the research, prospective or retrospective design, sample size, presence/absence of confidence intervals (CIs), nature of the statistical analysis, and major analysis problems. Of 58 articles, 31% were phase I (exploratory), 50% were phase II (challenge), and 19% were phase III (advanced) studies. The studies increased in sample size from phase I to III and showed a progression in the use of prospective designs. Most phase I studies were powered to assess diagnostic tests with ROC areas >/=0.70. Thirty-eight percent of studies failed to include CIs for diagnostic test accuracy or the CIs were constructed inappropriately. Thirty-three percent of studies provided insufficient analysis for comparing diagnostic tests. Other problems included dichotomization of the gold standard scale and inappropriate analysis of the equivalence of two diagnostic tests. We identify available software and make some suggestions for sample size determination, testing for equivalence in diagnostic accuracy, and alternatives to a dichotomous classification of a continuous-scale gold standard. More methodologic research is needed in areas specific to clinical chemistry.

  3. Physical examination tests for the diagnosis of posterior cruciate ligament rupture: a systematic review.

    PubMed

    Kopkow, Christian; Freiberg, Alice; Kirschner, Stephan; Seidler, Andreas; Schmitt, Jochen

    2013-11-01

    Systematic literature review. To summarize and evaluate research on the accuracy of physical examination tests for diagnosis of posterior cruciate ligament (PCL) tear. Rupture of the PCL is a severe knee injury that can lead to delayed rehabilitation, instability, or chronic knee pathologies. To our knowledge, there is currently no systematic review of studies on the diagnostic accuracy of clinical examination tests to evaluate the integrity of the PCL. A comprehensive systematic literature search was conducted in MEDLINE from 1946, Embase from 1974, and the Allied and Complementary Medicine Database from 1985 until April 30, 2012. Studies were considered eligible if they compared the results of physical examination tests performed in the context of a PCL physical examination to those of a reference standard (arthroscopy, arthrotomy, magnetic resonance imaging). Methodological quality assessment was performed by 2 independent reviewers using the revised version of the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. The search strategy revealed 1307 articles, of which 11 met the inclusion criteria for this review. In these studies, 11 different physical examination tests were identified. Due to differences in study types, different patient populations, and methodological quality, meta-analysis was not indicated. Presently, most physical examination tests have not been evaluated sufficiently enough to be confident in their ability to either confirm or rule out a PCL tear. The diagnostic accuracy of physical examination tests to assess the integrity of the PCL is largely unknown. There is a strong need for further research in this area. Level of Evidence Diagnosis, level 3a.

  4. Full-arch implant fixed prostheses: a comparative study on the effect of connection type and impression technique on accuracy of fit.

    PubMed

    Papaspyridakos, Panos; Hirayama, Hiroshi; Chen, Chun-Jung; Ho, Chung-Han; Chronopoulos, Vasilios; Weber, Hans-Peter

    2016-09-01

    The aim of this study was to assess the effect of connection type and impression technique on the accuracy of fit of implant-supported fixed complete-arch dental prostheses (IFCDPs). An edentulous mandibular cast with five implants was fabricated to serve as master cast (control) for both implant- and abutment-level baselines. A titanium one-piece framework for an IFCDP was milled at abutment level and used for accuracy of fit measurements. Polyether impressions were made using a splinted and non-splinted technique at the implant and abutment level leading to four test groups, n = 10 each. Hence, four groups of test casts were generated. The impression accuracy was evaluated indirectly by assessing the fit of the IFCDP framework on the generated casts of the test groups, clinically and radiographically. Additionally, the control and all test casts were digitized with a high-resolution reference scanner (IScan D103i, Imetric, Courgenay, Switzerland) and standard tessellation language datasets were generated and superimposed. Potential correlations between the clinical accuracy of fit data and the data from the digital scanning were investigated. To compare the accuracy of casts of the test groups versus the control at the implant and abutment level, Fisher's exact test was used. Of the 10 casts of test group I (implant-level splint), all 10 presented with accurate clinical fit when the framework was seated on its respective cast, while only five of 10 casts of test group II (implant-level non-splint) showed adequate fit. All casts of group III (abutment-level splint) presented with accurate fit, whereas nine of 10 of the casts of test group IV (abutment-level non-splint) were accurate. Significant 3D deviations (P < 0.05) were found between group II and the control. No statistically significant differences were found between groups I, III, and IV compared with the control. Implant connection type (implant level vs. abutment level) and impression technique did affect the 3D accuracy of implant impressions only with the non-splint technique (P < 0.05). For one-piece IFCDPs, the implant-level splinted impression technique showed to be more accurate than the non-splinted approach, whereas at the abutment-level, no difference in the accuracy was found. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Characterization of medical students recall of factual knowledge using learning objects and repeated testing in a novel e-learning system.

    PubMed

    Taveira-Gomes, Tiago; Prado-Costa, Rui; Severo, Milton; Ferreira, Maria Amélia

    2015-01-24

    Spaced-repetition and test-enhanced learning are two methodologies that boost knowledge retention. ALERT STUDENT is a platform that allows creation and distribution of Learning Objects named flashcards, and provides insight into student judgments-of-learning through a metric called 'recall accuracy'. This study aims to understand how the spaced-repetition and test-enhanced learning features provided by the platform affect recall accuracy, and to characterize the effect that students, flashcards and repetitions exert on this measurement. Three spaced laboratory sessions (s0, s1 and s2), were conducted with n=96 medical students. The intervention employed a study task, and a quiz task that consisted in mentally answering open-ended questions about each flashcard and grading recall accuracy. Students were randomized into study-quiz and quiz groups. On s0 both groups performed the quiz task. On s1 and s2, the study-quiz group performed the study task followed by the quiz task, whereas the quiz group only performed the quiz task. We measured differences in recall accuracy between groups/sessions, its variance components, and the G-coefficients for the flashcard component. At s0 there were no differences in recall accuracy between groups. The experiment group achieved a significant increase in recall accuracy that was superior to the quiz group in s1 and s2. In the study-quiz group, increases in recall accuracy were mainly due to the session, followed by flashcard factors and student factors. In the quiz group, increases in recall accuracy were mainly accounted by flashcard factors, followed by student and session factors. The flashcard G-coefficient indicated an agreement on recall accuracy of 91% in the quiz group, and of 47% in the study-quiz group. Recall accuracy is an easily collectible measurement that increases the educational value of Learning Objects and open-ended questions. This metric seems to vary in a way consistent with knowledge retention, but further investigation is necessary to ascertain the nature of such relationship. Recall accuracy has educational implications to students and educators, and may contribute to deliver tailored learning experiences, assess the effectiveness of instruction, and facilitate research comparing blended-learning interventions.

  6. Cluster Detection Tests in Spatial Epidemiology: A Global Indicator for Performance Assessment

    PubMed Central

    Guttmann, Aline; Li, Xinran; Feschet, Fabien; Gaudart, Jean; Demongeot, Jacques; Boire, Jean-Yves; Ouchchane, Lemlih

    2015-01-01

    In cluster detection of disease, the use of local cluster detection tests (CDTs) is current. These methods aim both at locating likely clusters and testing for their statistical significance. New or improved CDTs are regularly proposed to epidemiologists and must be subjected to performance assessment. Because location accuracy has to be considered, performance assessment goes beyond the raw estimation of type I or II errors. As no consensus exists for performance evaluations, heterogeneous methods are used, and therefore studies are rarely comparable. A global indicator of performance, which assesses both spatial accuracy and usual power, would facilitate the exploration of CDTs behaviour and help between-studies comparisons. The Tanimoto coefficient (TC) is a well-known measure of similarity that can assess location accuracy but only for one detected cluster. In a simulation study, performance is measured for many tests. From the TC, we here propose two statistics, the averaged TC and the cumulated TC, as indicators able to provide a global overview of CDTs performance for both usual power and location accuracy. We evidence the properties of these two indicators and the superiority of the cumulated TC to assess performance. We tested these indicators to conduct a systematic spatial assessment displayed through performance maps. PMID:26086911

  7. Photon caliper to achieve submillimeter positioning accuracy

    NASA Astrophysics Data System (ADS)

    Gallagher, Kyle J.; Wong, Jennifer; Zhang, Junan

    2017-09-01

    The purpose of this study was to demonstrate the feasibility of using a commercial two-dimensional (2D) detector array with an inherent detector spacing of 5 mm to achieve submillimeter accuracy in localizing the radiation isocenter. This was accomplished by delivering the Vernier ‘dose’ caliper to a 2D detector array where the nominal scale was the 2D detector array and the non-nominal Vernier scale was the radiation dose strips produced by the high-definition (HD) multileaf collimators (MLCs) of the linear accelerator. Because the HD MLC sequence was similar to the picket fence test, we called this procedure the Vernier picket fence (VPF) test. We confirmed the accuracy of the VPF test by offsetting the HD MLC bank by known increments and comparing the known offset with the VPF test result. The VPF test was able to determine the known offset within 0.02 mm. We also cross-validated the accuracy of the VPF test in an evaluation of couch hysteresis. This was done by using both the VPF test and the ExacTrac optical tracking system to evaluate the couch position. We showed that the VPF test was in agreement with the ExacTrac optical tracking system within a root-mean-square value of 0.07 mm for both the lateral and longitudinal directions. In conclusion, we demonstrated the VPF test can determine the offset between a 2D detector array and the radiation isocenter with submillimeter accuracy. Until now, no method to locate the radiation isocenter using a 2D detector array has been able to achieve such accuracy.

  8. Post-hoc simulation study to adopt a computerized adaptive testing (CAT) for a Korean Medical License Examination.

    PubMed

    Seo, Dong Gi; Choi, Jeongwook

    2018-05-17

    Computerized adaptive testing (CAT) has been adopted in license examinations due to a test efficiency and accuracy. Many research about CAT have been published to prove the efficiency and accuracy of measurement. This simulation study investigated scoring method and item selection methods to implement CAT in Korean medical license examination (KMLE). This study used post-hoc (real data) simulation design. The item bank used in this study was designed with all items in a 2017 KMLE. All CAT algorithms for this study were implemented by a 'catR' package in R program. In terms of accuracy, Rasch and 2parametric logistic (PL) model performed better than 3PL model. Modal a Posteriori (MAP) or Expected a Posterior (EAP) provided more accurate estimates than MLE and WLE. Furthermore Maximum posterior weighted information (MPWI) or Minimum expected posterior variance (MEPV) performed better than other item selection methods. In terms of efficiency, Rasch model was recommended to reduce test length. Simulation study should be performed under varied test conditions before adopting a live CAT. Based on a simulation study, specific scoring and item selection methods should be predetermined before implementing a live CAT.

  9. Estimating the Accuracy of Neurocognitive Effort Measures in the Absence of a "Gold Standard"

    ERIC Educational Resources Information Center

    Mossman, Douglas; Wygant, Dustin B.; Gervais, Roger O.

    2012-01-01

    Psychologists frequently use symptom validity tests (SVTs) to help determine whether evaluees' test performance or reported symptoms accurately represent their true functioning and capability. Most studies evaluating the accuracy of SVTs have used either known-group comparisons or simulation designs, but these approaches have well-known…

  10. System Accuracy Evaluation of Four Systems for Self-Monitoring of Blood Glucose Following ISO 15197 Using a Glucose Oxidase and a Hexokinase-Based Comparison Method.

    PubMed

    Link, Manuela; Schmid, Christina; Pleus, Stefan; Baumstark, Annette; Rittmeyer, Delia; Haug, Cornelia; Freckmann, Guido

    2015-04-14

    The standard ISO (International Organization for Standardization) 15197 is widely accepted for the accuracy evaluation of systems for self-monitoring of blood glucose (SMBG). Accuracy evaluation was performed for 4 SMBG systems (Accu-Chek Aviva, ContourXT, GlucoCheck XL, GlucoMen LX PLUS) with 3 test strip lots each. To investigate a possible impact of the comparison method on system accuracy data, 2 different established methods were used. The evaluation was performed in a standardized manner following test procedures described in ISO 15197:2003 (section 7.3). System accuracy was assessed by applying ISO 15197:2003 and in addition ISO 15197:2013 criteria (section 6.3.3). For each system, comparison measurements were performed with a glucose oxidase (YSI 2300 STAT Plus glucose analyzer) and a hexokinase (cobas c111) method. All 4 systems fulfilled the accuracy requirements of ISO 15197:2003 with the tested lots. More stringent accuracy criteria of ISO 15197:2013 were fulfilled by 3 systems (Accu-Chek Aviva, ContourXT, GlucoMen LX PLUS) when compared to the manufacturer's comparison method and by 2 systems (Accu-Chek Aviva, ContourXT) when compared to the alternative comparison method. All systems showed lot-to-lot variability to a certain degree; 2 systems (Accu-Chek Aviva, ContourXT), however, showed only minimal differences in relative bias between the 3 evaluated lots. In this study, all 4 systems complied with the evaluated test strip lots with accuracy criteria of ISO 15197:2003. Applying ISO 15197:2013 accuracy limits, differences in the accuracy of the tested systems were observed, also demonstrating that the applied comparison method/system and the lot-to-lot variability can have a decisive influence on accuracy data obtained for a SMBG system. © 2015 Diabetes Technology Society.

  11. Homogeneity tests of clustered diagnostic markers with applications to the BioCycle Study

    PubMed Central

    Tang, Liansheng Larry; Liu, Aiyi; Schisterman, Enrique F.; Zhou, Xiao-Hua; Liu, Catherine Chun-ling

    2014-01-01

    Diagnostic trials often require the use of a homogeneity test among several markers. Such a test may be necessary to determine the power both during the design phase and in the initial analysis stage. However, no formal method is available for the power and sample size calculation when the number of markers is greater than two and marker measurements are clustered in subjects. This article presents two procedures for testing the accuracy among clustered diagnostic markers. The first procedure is a test of homogeneity among continuous markers based on a global null hypothesis of the same accuracy. The result under the alternative provides the explicit distribution for the power and sample size calculation. The second procedure is a simultaneous pairwise comparison test based on weighted areas under the receiver operating characteristic curves. This test is particularly useful if a global difference among markers is found by the homogeneity test. We apply our procedures to the BioCycle Study designed to assess and compare the accuracy of hormone and oxidative stress markers in distinguishing women with ovulatory menstrual cycles from those without. PMID:22733707

  12. Accuracy of five intraoral scanners compared to indirect digitalization.

    PubMed

    Güth, Jan-Frederik; Runkel, Cornelius; Beuer, Florian; Stimmelmayr, Michael; Edelhoff, Daniel; Keul, Christine

    2017-06-01

    Direct and indirect digitalization offer two options for computer-aided design (CAD)/ computer-aided manufacturing (CAM)-generated restorations. The aim of this study was to evaluate the accuracy of different intraoral scanners and compare them to the process of indirect digitalization. A titanium testing model was directly digitized 12 times with each intraoral scanner: (1) CS 3500 (CS), (2) Zfx Intrascan (ZFX), (3) CEREC AC Bluecam (BLU), (4) CEREC AC Omnicam (OC) and (5) True Definition (TD). As control, 12 polyether impressions were taken and the referring plaster casts were digitized indirectly with the D-810 laboratory scanner (CON). The accuracy (trueness/precision) of the datasets was evaluated by an analysing software (Geomagic Qualify 12.1) using a "best fit alignment" of the datasets with a highly accurate reference dataset of the testing model, received from industrial computed tomography. Direct digitalization using the TD showed the significant highest overall "trueness", followed by CS. Both performed better than CON. BLU, ZFX and OC showed higher differences from the reference dataset than CON. Regarding the overall "precision", the CS 3500 intraoral scanner and the True Definition showed the best performance. CON, BLU and OC resulted in significantly higher precision than ZFX did. Within the limitations of this in vitro study, the accuracy of the ascertained datasets was dependent on the scanning system. The direct digitalization was not superior to indirect digitalization for all tested systems. Regarding the accuracy, all tested intraoral scanning technologies seem to be able to reproduce a single quadrant within clinical acceptable accuracy. However, differences were detected between the tested systems.

  13. Proposal of a method for the evaluation of inaccuracy of home sphygmomanometers.

    PubMed

    Akpolat, Tekin

    2009-10-01

    There is no formal protocol for evaluating the individual accuracy of home sphygmomanometers. The aims of this study were to propose a method for achieving accuracy in automated home sphygmomanometers and to test the applicability of the defined method. The purposes of this method were to avoid major inaccuracies and to estimate the optimal circumstance for individual accuracy. The method has three stages and sequential measurement of blood pressure is used. The tested devices were categorized into four groups: accurate, acceptable, inaccurate and very inaccurate (major inaccuracy). The defined method takes approximately 10 min (excluding relaxation time) and was tested on three different occasions. The application of the method has shown that inaccuracy is a common problem among non-tested devices, that validated devices are superior to those that are non-validated or whose validation status is unknown, that major inaccuracy is common, especially in non-tested devices and that validation does not guarantee individual accuracy. A protocol addressing the accuracy of a particular sphygmomanometer in an individual patient is required, and a practical method has been suggested to achieve this. This method can be modified, but the main idea and approach should be preserved unless a better method is proposed. The purchase of validated devices and evaluation of accuracy for the purchased device in an individual patient will improve the monitoring of self-measurement of blood pressure at home. This study addresses device inaccuracy, but errors related to the patient, observer or blood pressure measurement technique should not be underestimated, and strict adherence to the manufacturer's instructions is essential.

  14. Using meta-analysis to inform the design of subsequent studies of diagnostic test accuracy.

    PubMed

    Hinchliffe, Sally R; Crowther, Michael J; Phillips, Robert S; Sutton, Alex J

    2013-06-01

    An individual diagnostic accuracy study rarely provides enough information to make conclusive recommendations about the accuracy of a diagnostic test; particularly when the study is small. Meta-analysis methods provide a way of combining information from multiple studies, reducing uncertainty in the result and hopefully providing substantial evidence to underpin reliable clinical decision-making. Very few investigators consider any sample size calculations when designing a new diagnostic accuracy study. However, it is important to consider the number of subjects in a new study in order to achieve a precise measure of accuracy. Sutton et al. have suggested previously that when designing a new therapeutic trial, it could be more beneficial to consider the power of the updated meta-analysis including the new trial rather than of the new trial itself. The methodology involves simulating new studies for a range of sample sizes and estimating the power of the updated meta-analysis with each new study added. Plotting the power values against the range of sample sizes allows the clinician to make an informed decision about the sample size of a new trial. This paper extends this approach from the trial setting and applies it to diagnostic accuracy studies. Several meta-analytic models are considered including bivariate random effects meta-analysis that models the correlation between sensitivity and specificity. Copyright © 2012 John Wiley & Sons, Ltd. Copyright © 2012 John Wiley & Sons, Ltd.

  15. Posterior Predictive Checks for Conditional Independence between Response Time and Accuracy

    ERIC Educational Resources Information Center

    Bolsinova, Maria; Tijmstra, Jesper

    2016-01-01

    Conditional independence (CI) between response time and response accuracy is a fundamental assumption of many joint models for time and accuracy used in educational measurement. In this study, posterior predictive checks (PPCs) are proposed for testing this assumption. These PPCs are based on three discrepancy measures reflecting different…

  16. Alaska national hydrography dataset positional accuracy assessment study

    USGS Publications Warehouse

    Arundel, Samantha; Yamamoto, Kristina H.; Constance, Eric; Mantey, Kim; Vinyard-Houx, Jeremy

    2013-01-01

    Initial visual assessments Wide range in the quality of fit between features in NHD and these new image sources. No statistical analysis has been performed to actually quantify accuracy Determining absolute accuracy is cost prohibitive (must collect independent, well defined test points) Quantitative analysis of relative positional error is feasible.

  17. Strategic Development for Middle School Students Struggling With Fractions: Assessment and Intervention.

    PubMed

    Zhang, Dake; Stecker, Pamela; Huckabee, Sloan; Miller, Rhonda

    2016-09-01

    Research has suggested that different strategies used when solving fraction problems are highly correlated with students' problem-solving accuracy. This study (a) utilized latent profile modeling to classify students into three different strategic developmental levels in solving fraction comparison problems and (b) accordingly provided differentiated strategic training for students starting from two different strategic developmental levels. In Study 1 we assessed 49 middle school students' performance on fraction comparison problems and categorized students into three clusters of strategic developmental clusters: a cross-multiplication cluster with the highest accuracy, a representation strategy cluster with medium accuracy, and a whole-number strategy cluster with the lowest accuracy. Based on the strategic developmental levels identified in Study 1, in Study 2 we selected three students from the whole-number strategy cluster and another three students from the representation strategy cluster and implemented a differentiated strategic training intervention within a multiple-baseline design. Results showed that both groups of students transitioned from less advanced to more advanced strategies and improved their problem-solving accuracy during the posttest, the maintenance test, and the generalization test. © Hammill Institute on Disabilities 2014.

  18. Assessment of colon polyp morphology: Is education effective?

    PubMed Central

    Kim, Jae Hyun; Nam, Kyoung Sik; Kwon, Hye Jung; Choi, Youn Jung; Jung, Kyoungwon; Kim, Sung Eun; Moon, Won; Park, Moo In; Park, Seun Ja

    2017-01-01

    AIM To determine the inter-observer variability for colon polyp morphology and to identify whether education can improve agreement among observers. METHODS For purposes of the tests, we recorded colonoscopy video clips that included scenes visualizing the polyps. A total of 15 endoscopists and 15 nurses participated in the study. Participants watched 60 video clips of the polyp morphology scenes and then estimated polyp morphology (pre-test). After education for 20 min, participants performed a second test in which the order of 60 video clips was changed (post-test). To determine if the effectiveness of education was sustained, four months later, a third, follow-up test was performed with the same participants. RESULTS The overall Fleiss’ kappa value of the inter-observer agreement was 0.510 in the pre-test, 0.618 in the post-test, and 0.580 in the follow-up test. The overall diagnostic accuracy of the estimation for polyp morphology in the pre-, post-, and follow-up tests was 0.662, 0.797, and 0.761, respectively. After education, the inter-observer agreement and diagnostic accuracy of all participants improved. However, after four months, the inter-observer agreement and diagnostic accuracy of expert groups were markedly decreased, and those of beginner and nurse groups remained similar to pre-test levels. CONCLUSION The education program used in this study can improve inter-observer agreement and diagnostic accuracy in assessing the morphology of colon polyps; it is especially effective when first learning endoscopy. PMID:28974894

  19. Assessment of colon polyp morphology: Is education effective?

    PubMed

    Kim, Jae Hyun; Nam, Kyoung Sik; Kwon, Hye Jung; Choi, Youn Jung; Jung, Kyoungwon; Kim, Sung Eun; Moon, Won; Park, Moo In; Park, Seun Ja

    2017-09-14

    To determine the inter-observer variability for colon polyp morphology and to identify whether education can improve agreement among observers. For purposes of the tests, we recorded colonoscopy video clips that included scenes visualizing the polyps. A total of 15 endoscopists and 15 nurses participated in the study. Participants watched 60 video clips of the polyp morphology scenes and then estimated polyp morphology (pre-test). After education for 20 min, participants performed a second test in which the order of 60 video clips was changed (post-test). To determine if the effectiveness of education was sustained, four months later, a third, follow-up test was performed with the same participants. The overall Fleiss' kappa value of the inter-observer agreement was 0.510 in the pre-test, 0.618 in the post-test, and 0.580 in the follow-up test. The overall diagnostic accuracy of the estimation for polyp morphology in the pre-, post-, and follow-up tests was 0.662, 0.797, and 0.761, respectively. After education, the inter-observer agreement and diagnostic accuracy of all participants improved. However, after four months, the inter-observer agreement and diagnostic accuracy of expert groups were markedly decreased, and those of beginner and nurse groups remained similar to pre-test levels. The education program used in this study can improve inter-observer agreement and diagnostic accuracy in assessing the morphology of colon polyps; it is especially effective when first learning endoscopy.

  20. A Meta-Analysis of Typhoid Diagnostic Accuracy Studies: A Recommendation to Adopt a Standardized Composite Reference

    PubMed Central

    Storey, Helen L.; Huang, Ying; Crudder, Chris; Golden, Allison; de los Santos, Tala; Hawkins, Kenneth

    2015-01-01

    Novel typhoid diagnostics currently under development have the potential to improve clinical care, surveillance, and the disease burden estimates that support vaccine introduction. Blood culture is most often used as the reference method to evaluate the accuracy of new typhoid tests; however, it is recognized to be an imperfect gold standard. If no single gold standard test exists, use of a composite reference standard (CRS) can improve estimation of diagnostic accuracy. Numerous studies have used a CRS to evaluate new typhoid diagnostics; however, there is no consensus on an appropriate CRS. In order to evaluate existing tests for use as a reference test or inclusion in a CRS, we performed a systematic review of the typhoid literature to include all index/reference test combinations observed. We described the landscape of comparisons performed, showed results of a meta-analysis on the accuracy of the more common combinations, and evaluated sources of variability based on study quality. This wide-ranging meta-analysis suggests that no single test has sufficiently good performance but some existing diagnostics may be useful as part of a CRS. Additionally, based on findings from the meta-analysis and a constructed numerical example demonstrating the use of CRS, we proposed necessary criteria and potential components of a typhoid CRS to guide future recommendations. Agreement and adoption by all investigators of a standardized CRS is requisite, and would improve comparison of new diagnostics across independent studies, leading to the identification of a better reference test and improved confidence in prevalence estimates. PMID:26566275

  1. Assessment of the accuracy and stability of frameless gamma knife radiosurgery.

    PubMed

    Chung, Hyun-Tai; Park, Woo-Yoon; Kim, Tae Hoon; Kim, Yong Kyun; Chun, Kook Jin

    2018-06-03

    The aim of this study was to assess the accuracy and stability of frameless gamma knife radiosurgery (GKRS). The accuracies of the radiation isocenter and patient couch movement were evaluated by film dosimetry with a half-year cycle. Radiation isocenter assessment with a diode detector and cone-beam computed tomography (CBCT) image accuracy tests were performed daily with a vendor-provided tool for one and a half years after installation. CBCT image quality was examined twice a month with a phantom. The accuracy of image coregistration using CBCT images was studied using magnetic resonance (MR) and computed tomography (CT) images of another phantom. The overall positional accuracy was measured in whole procedure tests using film dosimetry with an anthropomorphic phantom. The positional errors of the radiation isocenter at the center and at an extreme position were both less than 0.1 mm. The three-dimensional deviation of the CBCT coordinate system was stable for one and a half years (mean 0.04 ± 0.02 mm). Image coregistration revealed a difference of 0.2 ± 0.1 mm between CT and CBCT images and a deviation of 0.4 ± 0.2 mm between MR and CBCT images. The whole procedure test of the positional accuracy of the mask-based irradiation revealed an accuracy of 0.5 ± 0.6 mm. The radiation isocenter accuracy, patient couch movement accuracy, and Gamma Knife Icon CBCT accuracy were all approximately 0.1 mm and were stable for one and a half years. The coordinate system assigned to MR images through coregistration was more accurate than the system defined by fiducial markers. Possible patient motion during irradiation should be considered when evaluating the overall accuracy of frameless GKRS. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  2. Testing a tool for the classification of study designs in systematic reviews of interventions and exposures showed moderate reliability and low accuracy.

    PubMed

    Hartling, Lisa; Bond, Kenneth; Santaguida, P Lina; Viswanathan, Meera; Dryden, Donna M

    2011-08-01

    To develop and test a study design classification tool. We contacted relevant organizations and individuals to identify tools used to classify study designs and ranked these using predefined criteria. The highest ranked tool was a design algorithm developed, but no longer advocated, by the Cochrane Non-Randomized Studies Methods Group; this was modified to include additional study designs and decision points. We developed a reference classification for 30 studies; 6 testers applied the tool to these studies. Interrater reliability (Fleiss' κ) and accuracy against the reference classification were assessed. The tool was further revised and retested. Initial reliability was fair among the testers (κ=0.26) and the reference standard raters κ=0.33). Testing after revisions showed improved reliability (κ=0.45, moderate agreement) with improved, but still low, accuracy. The most common disagreements were whether the study design was experimental (5 of 15 studies), and whether there was a comparison of any kind (4 of 15 studies). Agreement was higher among testers who had completed graduate level training versus those who had not. The moderate reliability and low accuracy may be because of lack of clarity and comprehensiveness of the tool, inadequate reporting of the studies, and variability in tester characteristics. The results may not be generalizable to all published studies, as the test studies were selected because they had posed challenges for previous reviewers with respect to their design classification. Application of such a tool should be accompanied by training, pilot testing, and context-specific decision rules. Copyright © 2011 Elsevier Inc. All rights reserved.

  3. Diagnostic test accuracy of nutritional tools used to identify undernutrition in patients with colorectal cancer: a systematic review.

    PubMed

    Håkonsen, Sasja Jul; Pedersen, Preben Ulrich; Bath-Hextall, Fiona; Kirkpatrick, Pamela

    2015-05-15

    Effective nutritional screening, nutritional care planning and nutritional support are essential in all settings, and there is no doubt that a health service seeking to increase safety and clinical effectiveness must take nutritional care seriously. Screening and early detection of malnutrition is crucial in identifying patients at nutritional risk. There is a high prevalence of malnutrition in hospitalized patients undergoing treatment for colorectal cancer. To synthesize the best available evidence regarding the diagnostic test accuracy of nutritional tools (sensitivity and specificity) used to identify malnutrition (specifically undernutrition) in patients with colorectal cancer (such as the Malnutrition Screening Tool and Nutritional Risk Index) compared to reference tests (such as the Subjective Global Assessment or Patient Generated Subjective Global Assessment). Patients with colorectal cancer requiring either (or all) surgery, chemotherapy and/or radiotherapy in secondary care. Focus of the review: The diagnostic test accuracy of validated assessment tools/instruments (such as the Malnutrition Screening Tool and Nutritional Risk Index) in the diagnosis of malnutrition (specifically under-nutrition) in patients with colorectal cancer, relative to reference tests (Subjective Global Assessment or Patient Generated Subjective Global Assessment). Types of studies: Diagnostic test accuracy studies regardless of study design. Studies published in English, German, Danish, Swedish and Norwegian were considered for inclusion in this review. Databases were searched from their inception to April 2014. Methodological quality was determined using the Quality Assessment of Diagnostic Accuracy Studies checklist. Data was collected using the data extraction form: the Standards for Reporting Studies of Diagnostic Accuracy checklist for the reporting of studies of diagnostic accuracy. The accuracy of diagnostic tests is presented in terms of sensitivity, specificity, positive and negative predictive values. In addition, the positive likelihood ratio (sensitivity/ [1 - specificity]) and negative likelihood ratio (1 - sensitivity)/ specificity), were also calculated and presented in this review to provide information about the likelihood that a given test result would be expected when the target condition is present compared with the likelihood that the same result would be expected when the condition is absent. Not all trials reported true positive, true negative, false positive and false negative rates, therefore these rates were calculated based on the data in the published papers. A two-by-two truth table was reconstructed for each study, and sensitivity, specificity, positive predictive value, negative predictive value positive likelihood ratio and negative likelihood ratio were calculated for each study. A summary receiver operator characteristics curve was constructed to determine the relationship between sensitivity and specificity, and the area under the summary receiver operator characteristics curve which measured the usefulness of a test was calculated. Meta-analysis was not considered appropriate, therefore data was synthesized in a narrative summary. 1. One study evaluated the Malnutrition Screening Tool against the reference standard Patient-Generated Subjective Global Assessment. The sensitivity was 56% and the specificity 84%. The positive likelihood ratio was 3.100, negative likelihood ratio was 0.59, the diagnostic odds ratio (CI 95%) was 5.20 (1.09-24.90) and the Area Under the Curve (AUC) represents only a poor to fair diagnostic test accuracy. A total of two studies evaluated the diagnostic accuracy of Malnutrition Universal Screening Tool (MUST) (index test) compared to both Subjective Global Assessment (SGA) (reference standard) and PG-SGA (reference standard) in patients with colorectal cancer. In MUST vs SGA the sensitivity of the tool was 96%, specificity was 75%, LR+ 3.826, LR- 0.058, diagnostic OR (CI 95%) 66.00 (6.61-659.24) and AUC represented excellent diagnostic accuracy. In MUST vs PG-SGA the sensitivity of the tool was 72%, specificity 48.9%, LR+ 1.382, LR- 0.579, diagnostic OR (CI 95%) 2.39 (0.87-6.58) and AUC indicated that the tool failed as a diagnostic test to identify patients with colorectal cancer at nutritional risk,. The Nutrition Risk Index (NRI) was compared to SGA representing a sensitivity of 95.2%, specificity of 62.5%, LR+ 2.521, LR- 0.087, diagnostic OR (CI 95%) 28.89 (6.93-120.40) and AUC represented good diagnostic accuracy. In regard to NRI vs PG-SGA the sensitivity of the tool was 68%, specificity 64%, LR+ 1.947, LR- 0.487, diagnostic OR (CI 95%) 4.00 (1.23-13.01) and AUC indicated poor diagnostic test accuracy. There are no single, specific tools used to screen or assess the nutritional status of colorectal cancer patients. All tools showed varied diagnostic accuracies when compared to the reference standards SGA and PG-SGA. Hence clinical judgment combined with perhaps the SGA or PG-SGA should play a major role. The PG-SGA offers several advantages over the SGA tool: 1) the patient completes the medical history component, thereby decreasing the amount of time involved; 2) it contains more nutrition impact symptoms, which are important to the patient with cancer; and 3) it has a scoring system that allows patients to be triaged for nutritional intervention. Therefore, the PG-SGA could be used as a nutrition assessment tool as it allows quick identification and prioritization of colorectal cancer patients with malnutrition in combination with other parameters. This systematic review highlights the need for the following: Further studies needs to investigate the diagnostic accuracy of already existing nutritional screening tools in the context of colorectal cancer patients. If new screenings tools are developed, they should be developed and validated in the specific clinical context within the same patient population (colorectal cancer patients). The Joanna Briggs Institute.

  4. F-18 FDG PET, CT, and MRI for detecting the malignant potential in patients with gastrointestinal stromal tumors: A protocol for a network meta-analysis of diagnostic test accuracy.

    PubMed

    Wei, Kongyuan; Pan, Bei; Yang, Huan; Lu, Cuncun; Ge, Long; Cao, Nong

    2018-04-01

    Gastrointestinal stromal tumor (GIST) is a rare cancer in gastrointestinal carcinomas and has been widely known as a curable disease among all the digestive tumors. However, early detection of malignant potential in patients with GIST has still been a huge challenge all around the world. CT, MRI, and F-18 FDG PET are all considered as good tests for diagnosing malignant GIST efficiently, but no recommended suggestions presents which test among the 3 is the prior one in detecting the malignant potential of GIST. We perform this study to assess the accuracy between CT, MRI, and F-18 FDG PET through network meta-analysis method, and to rank these tests. PubMed, EMBASE.com, CNKI, and CBM databases will be searched without search date and language restrictions. We will include diagnostic tests which assessed the accuracy of CT, MRI, and F-18 FDG PET in detecting the malignant potential of GIST. The risk of bias in each study will be independently assessed as low, moderate, or high using criteria adapted from Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2). Meta-analysis will be performed using STATA 12.0 and R 3.4.1 software. The competing diagnostic tests will be ranked by a superiority index. This study is ongoing, and will be submitted to a peer-reviewed journal for publication. This study will provide a comprehensive evidence summary of CT, MRI, and F-18 FDG PET in detecting the malignant potential of GIST.

  5. Geometric validation of a mobile laser scanning system for urban applications

    NASA Astrophysics Data System (ADS)

    Guan, Haiyan; Li, Jonathan; Yu, Yongtao; Liu, Yan

    2016-03-01

    Mobile laser scanning (MLS) technologies have been actively studied and implemented over the past decade, as their application fields are rapidly expanding and extending beyond conventional topographic mapping. Trimble's MX-8, as one of the MLS systems in the current market, generates rich survey-grade laser and image data for urban surveying. The objective of this study is to evaluate whether Trimble MX-8 MLS data satisfies the accuracy requirements of urban surveying. According to the formula of geo-referencing, accuracies of navigation solution and laser scanner determines the accuracy of the collected LiDAR point clouds. Two test sites were selected to test the performance of Trimble MX-8. Those extensive tests confirm that Trimble MX-8 offers a very promising tool to survey complex urban areas.

  6. Using simple artificial intelligence methods for predicting amyloidogenesis in antibodies

    PubMed Central

    2010-01-01

    Background All polypeptide backbones have the potential to form amyloid fibrils, which are associated with a number of degenerative disorders. However, the likelihood that amyloidosis would actually occur under physiological conditions depends largely on the amino acid composition of a protein. We explore using a naive Bayesian classifier and a weighted decision tree for predicting the amyloidogenicity of immunoglobulin sequences. Results The average accuracy based on leave-one-out (LOO) cross validation of a Bayesian classifier generated from 143 amyloidogenic sequences is 60.84%. This is consistent with the average accuracy of 61.15% for a holdout test set comprised of 103 AM and 28 non-amyloidogenic sequences. The LOO cross validation accuracy increases to 81.08% when the training set is augmented by the holdout test set. In comparison, the average classification accuracy for the holdout test set obtained using a decision tree is 78.64%. Non-amyloidogenic sequences are predicted with average LOO cross validation accuracies between 74.05% and 77.24% using the Bayesian classifier, depending on the training set size. The accuracy for the holdout test set was 89%. For the decision tree, the non-amyloidogenic prediction accuracy is 75.00%. Conclusions This exploratory study indicates that both classification methods may be promising in providing straightforward predictions on the amyloidogenicity of a sequence. Nevertheless, the number of available sequences that satisfy the premises of this study are limited, and are consequently smaller than the ideal training set size. Increasing the size of the training set clearly increases the accuracy, and the expansion of the training set to include not only more derivatives, but more alignments, would make the method more sound. The accuracy of the classifiers may also be improved when additional factors, such as structural and physico-chemical data, are considered. The development of this type of classifier has significant applications in evaluating engineered antibodies, and may be adapted for evaluating engineered proteins in general. PMID:20144194

  7. Using simple artificial intelligence methods for predicting amyloidogenesis in antibodies.

    PubMed

    David, Maria Pamela C; Concepcion, Gisela P; Padlan, Eduardo A

    2010-02-08

    All polypeptide backbones have the potential to form amyloid fibrils, which are associated with a number of degenerative disorders. However, the likelihood that amyloidosis would actually occur under physiological conditions depends largely on the amino acid composition of a protein. We explore using a naive Bayesian classifier and a weighted decision tree for predicting the amyloidogenicity of immunoglobulin sequences. The average accuracy based on leave-one-out (LOO) cross validation of a Bayesian classifier generated from 143 amyloidogenic sequences is 60.84%. This is consistent with the average accuracy of 61.15% for a holdout test set comprised of 103 AM and 28 non-amyloidogenic sequences. The LOO cross validation accuracy increases to 81.08% when the training set is augmented by the holdout test set. In comparison, the average classification accuracy for the holdout test set obtained using a decision tree is 78.64%. Non-amyloidogenic sequences are predicted with average LOO cross validation accuracies between 74.05% and 77.24% using the Bayesian classifier, depending on the training set size. The accuracy for the holdout test set was 89%. For the decision tree, the non-amyloidogenic prediction accuracy is 75.00%. This exploratory study indicates that both classification methods may be promising in providing straightforward predictions on the amyloidogenicity of a sequence. Nevertheless, the number of available sequences that satisfy the premises of this study are limited, and are consequently smaller than the ideal training set size. Increasing the size of the training set clearly increases the accuracy, and the expansion of the training set to include not only more derivatives, but more alignments, would make the method more sound. The accuracy of the classifiers may also be improved when additional factors, such as structural and physico-chemical data, are considered. The development of this type of classifier has significant applications in evaluating engineered antibodies, and may be adapted for evaluating engineered proteins in general.

  8. Retrieving self-vocalized information: An event-related potential (ERP) study on the effect of retrieval orientation.

    PubMed

    Rosburg, Timm; Johansson, Mikael; Sprondel, Volker; Mecklinger, Axel

    2014-11-18

    Retrieval orientation refers to a pre-retrieval process and conceptualizes the specific form of processing that is applied to a retrieval cue. In the current event-related potential (ERP) study, we sought to find evidence for an involvement of the auditory cortex when subjects attempt to retrieve vocalized information, and hypothesized that adopting retrieval orientation would be beneficial for retrieval accuracy. During study, participants saw object words that they subsequently vocalized or visually imagined. At test, participants had to identify object names of one study condition as targets and to reject object names of the second condition together with new items. Target category switched after half of the test trials. Behaviorally, participants responded less accurately and more slowly to targets of the vocalize condition than to targets of the imagine condition. ERPs to new items varied at a single left electrode (T7) between 500 and 800ms, indicating a moderate retrieval orientation effect in the subject group as a whole. However, whereas the effect was strongly pronounced in participants with high retrieval accuracy, it was absent in participants with low retrieval accuracy. A current source density (CSD) mapping of the retrieval orientation effect indicated a source over left temporal regions. Independently from retrieval accuracy, the ERP retrieval orientation effect was surprisingly also modulated by test order. Findings are suggestive for an involvement of the auditory cortex in retrieval attempts of vocalized information and confirm that adopting retrieval orientation is potentially beneficial for retrieval accuracy. The effects of test order on retrieval-related processes might reflect a stronger focus on the newness of items in the more difficult test condition when participants started with this condition. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Accuracy of velocities from repeated GPS surveys: relative positioning is concerned

    NASA Astrophysics Data System (ADS)

    Duman, Huseyin; Ugur Sanli, D.

    2016-04-01

    Over more than a decade, researchers have been interested in studying the accuracy of GPS positioning solutions. Recently, reporting the accuracy of GPS velocities has been added to this. Researchers studying landslide motion, tectonic motion, uplift, sea level rise, and subsidence still report results from GPS experiments in which repeated GPS measurements from short sessions are used. This motivated some other researchers to study the accuracy of GPS deformation rates/velocities from various repeated GPS surveys. In one of the efforts, the velocity accuracy was derived from repeated GPS static surveys using short observation sessions and Precise Point Positioning mode of GPS software. Velocities from short GPS sessions were compared with the velocities from 24 h sessions. The accuracy of velocities was obtained using statistical hypothesis testing and quantifying the accuracy of least squares estimation models. The results reveal that 45-60 % of the horizontal and none of the vertical solutions comply with the results from 24 h solutions. We argue that this case in which the data was evaluated using PPP should also apply to the case in which the data belonging to long GPS base lengths is processed using fundamental relative point positioning. To test this idea we chose the two IGS stations ANKR and NICO and derive their velocities from the reference stations held fixed in the stable EURASIAN plate. The University of Bern's GNSS software BERNESE was used to produce relative positioning solutions, and the results are compared with those of GIPSY/OASIS II PPP results. First impressions indicate that it is worth designing a global experiment and test these ideas in detail.

  10. Can mandibular bone resorption predict hip fracture in elderly women? A systematic review of diagnostic test accuracy.

    PubMed

    Devlin, Hugh; Whelton, Christopher

    2015-09-01

    The aim of this systematic review was to determine the diagnostic accuracy of the mandibular cortical width measurements and porosity in detecting hip osteoporosis. All of the included studies used measurements on panoramic radiographs. Studies were included if they compared the radiographic measurements (or index tests) with central dual energy X-ray absorptiometry (DXA) of the hip as the reference standard. A measure of diagnostic accuracy such as sensitivity and specificity or area under the receiver operating characteristic curve was also required for inclusion. Seven studies were identified. Meta-analysis was not possible because of the heterogeneity of the studies. The studies all demonstrated moderate diagnostic accuracy. If a patient with a thin or porous mandibular cortex is identified by a chance radiographic finding, additional clinical risk factors need to be considered and the patient referred for further investigation with DXA where necessary. © 2013 John Wiley & Sons A/S and The Gerodontology Society. Published by John Wiley & Sons Ltd.

  11. A Concurrent Test of Accuracy-of-Classification for the Strong Vocational Interest and Kuder Occupational Interest Survey

    ERIC Educational Resources Information Center

    Zytowski, Donald G.

    1972-01-01

    Owing to the uncertainty concerning the concurrent validity of the SVIB and the KOIS, a test of accuracy of classification of men in the occupations common to both inventories was undertaken. The results suggest that neither show any less validity than had been shown in separate studies previously. (Author)

  12. Developing Local Oral Reading Fluency Cut Scores for Predicting High-Stakes Test Performance

    ERIC Educational Resources Information Center

    Grapin, Sally L.; Kranzler, John H.; Waldron, Nancy; Joyce-Beaulieu, Diana; Algina, James

    2017-01-01

    This study evaluated the classification accuracy of a second grade oral reading fluency curriculum-based measure (R-CBM) in predicting third grade state test performance. It also compared the long-term classification accuracy of local and publisher-recommended R-CBM cut scores. Participants were 266 students who were divided into a calibration…

  13. The power of timing: Adding a time-to-completion cutoff to the Word Choice Test and Recognition Memory Test improves classification accuracy.

    PubMed

    Erdodi, Laszlo A; Tyson, Bradley T; Shahein, Ayman G; Lichtenstein, Jonathan D; Abeare, Christopher A; Pelletier, Chantalle L; Zuccato, Brandon G; Kucharski, Brittany; Roth, Robert M

    2017-05-01

    The Recognition Memory Test (RMT) and Word Choice Test (WCT) are structurally similar, but psychometrically different. Previous research demonstrated that adding a time-to-completion cutoff improved the classification accuracy of the RMT. However, the contribution of WCT time-cutoffs to improve the detection of invalid responding has not been investigated. The present study was designed to evaluate the classification accuracy of time-to-completion on the WCT compared to the accuracy score and the RMT. Both tests were administered to 202 adults (M age  = 45.3 years, SD = 16.8; 54.5% female) clinically referred for neuropsychological assessment in counterbalanced order as part of a larger battery of cognitive tests. Participants obtained lower and more variable scores on the RMT (M = 44.1, SD = 7.6) than on the WCT (M = 46.9, SD = 5.7). Similarly, they took longer to complete the recognition trial on the RMT (M = 157.2 s,SD = 71.8) than the WCT (M = 137.2 s, SD = 75.7). The optimal cutoff on the RMT (≤43) produced .60 sensitivity at .87 specificity. The optimal cutoff on the WCT (≤47) produced .57 sensitivity at .87 specificity. Time-cutoffs produced comparable classification accuracies for both RMT (≥192 s; .48 sensitivity at .88 specificity) and WCT (≥171 s; .49 sensitivity at .91 specificity). They also identified an additional 6-10% of the invalid profiles missed by accuracy score cutoffs, while maintaining good specificity (.93-.95). Functional equivalence was reached at accuracy scores ≤43 (RMT) and ≤47 (WCT) or time-to-completion ≥192 s (RMT) and ≥171 s (WCT). Time-to-completion cutoffs are valuable additions to both tests. They can function as independent validity indicators or enhance the sensitivity of accuracy scores without requiring additional measures or extending standard administration time.

  14. Accuracy of physical examination for chronic lumbar radiculopathy

    PubMed Central

    2013-01-01

    Background Clinical examination of patients with chronic lumbar radiculopathy aims to clarify whether there is nerve root impingement. The aims of this study were to investigate the association between findings at clinical examination and nerve root impingement, to evaluate the accuracy of clinical index tests in a specialised care setting, and to see whether imaging clarifies the cause of chronic radicular pain. Methods A total of 116 patients referred with symptoms of lumbar radiculopathy lasting more than 12 weeks and at least one positive index test were included. The tests were the straight leg raising test, and tests for motor muscle strength, dermatome sensory loss, and reflex impairment. Magnetic resonance imaging (n = 109) or computer tomography (n = 7) were imaging reference standards. Images were analysed at the level of single nerve root(s), and nerve root impingement was classified as present or absent. Sensitivities, specificities, and positive and negative likelihood ratios (LR) for detection of nerve root impingement were calculated for each individual index test. An overall clinical evaluation, concluding on the level and side of the radiculopathy, was performed. Results The prevalence of disc herniation was 77.8%. The diagnostic accuracy of individual index tests was low with no tests reaching positive LR >4.0 or negative LR <0.4. The overall clinical evaluation was slightly more accurate, with a positive LR of 6.28 (95% CI 1.06–37.21) for L4, 1.74 (95% CI 1.04–2.93) for L5, and 1.29 (95% CI 0.97–1.72) for S1 nerve root impingement. An overall clinical evaluation, concluding on the level and side of the radiculopathy was also performed, and receiver operating characteristic (ROC) analysis with area under the curve (AUC) calculation for diagnostic accuracy of this evaluation was performed. Conclusions The accuracy of individual clinical index tests used to predict imaging findings of nerve root impingement in patients with chronic lumbar radiculopathy is low when applied in specialised care, but clinicians’ overall evaluation improves diagnostic accuracy slightly. The tests are not very helpful in clarifying the cause of radicular pain, and are therefore inaccurate for guidance in the diagnostic workup of the patients. The study population was highly selected and therefore the results from this study should not be generalised to unselected patient populations in primary care nor to even more selected surgical populations. PMID:23837886

  15. Perceptual-cognitive expertise of handball coaches in their young and middle adult years.

    PubMed

    Fischer, Lennart; Baker, Joseph; Rienhoff, Rebecca; Strauß, Bernd; Tirp, Judith; Büsch, Dirk; Schorer, Jörg

    2016-09-01

    There is little research investigating the maintenance of perceptual-cognitive expertise in general and even less comparing coaches of different ages. The aim of this study was to test for perceptual-cognitive differences between age groups, licence levels, and their interaction. This study investigated differences in skilled performance between young and middle-aged coaches of three different skill levels. Participants performed an accuracy-oriented pattern recall (mean distance in pixel) and a time-oriented flicker test (mean detection time in ms). There were some significant differences between age groups and between skill groups for both tests, but no interactions. For the pattern recall test, the effect sizes were larger for skill level differences, while for the flicker test effects were larger for ageing. These results suggest coaches are able to maintain accuracy skills better than reaction timed tasks. This is in line with findings on speeded performance in general populations, which show declines with age. Moreover, results also support findings on perceptual expertise in skills where accuracy was important.

  16. Implicit recognition based on lateralized perceptual fluency.

    PubMed

    Vargas, Iliana M; Voss, Joel L; Paller, Ken A

    2012-02-06

    In some circumstances, accurate recognition of repeated images in an explicit memory test is driven by implicit memory. We propose that this "implicit recognition" results from perceptual fluency that influences responding without awareness of memory retrieval. Here we examined whether recognition would vary if images appeared in the same or different visual hemifield during learning and testing. Kaleidoscope images were briefly presented left or right of fixation during divided-attention encoding. Presentation in the same visual hemifield at test produced higher recognition accuracy than presentation in the opposite visual hemifield, but only for guess responses. These correct guesses likely reflect a contribution from implicit recognition, given that when the stimulated visual hemifield was the same at study and test, recognition accuracy was higher for guess responses than for responses with any level of confidence. The dramatic difference in guessing accuracy as a function of lateralized perceptual overlap between study and test suggests that implicit recognition arises from memory storage in visual cortical networks that mediate repetition-induced fluency increments.

  17. Diagnostic accuracy of level 3 portable sleep tests versus level 1 polysomnography for sleep-disordered breathing: a systematic review and meta-analysis

    PubMed Central

    El Shayeb, Mohamed; Topfer, Leigh-Ann; Stafinski, Tania; Pawluk, Lawrence; Menon, Devidas

    2014-01-01

    Background: Greater awareness of sleep-disordered breathing and rising obesity rates have fueled demand for sleep studies. Sleep testing using level 3 portable devices may expedite diagnosis and reduce the costs associated with level 1 in-laboratory polysomnography. We sought to assess the diagnostic accuracy of level 3 testing compared with level 1 testing and to identify the appropriate patient population for each test. Methods: We conducted a systematic review and meta-analysis of comparative studies of level 3 versus level 1 sleep tests in adults with suspected sleep-disordered breathing. We searched 3 research databases and grey literature sources for studies that reported on diagnostic accuracy parameters or disease management after diagnosis. Two reviewers screened the search results, selected potentially relevant studies and extracted data. We used a bivariate mixed-effects binary regression model to estimate summary diagnostic accuracy parameters. Results: We included 59 studies involving a total of 5026 evaluable patients (mostly patients suspected of having obstructive sleep apnea). Of these, 19 studies were included in the meta-analysis. The estimated area under the receiver operating characteristics curve was high, ranging between 0.85 and 0.99 across different levels of disease severity. Summary sensitivity ranged between 0.79 and 0.97, and summary specificity ranged between 0.60 and 0.93 across different apnea–hypopnea cut-offs. We saw no significant difference in the clinical management parameters between patients who underwent either test to receive their diagnosis. Interpretation: Level 3 portable devices showed good diagnostic performance compared with level 1 sleep tests in adult patients with a high pretest probability of moderate to severe obstructive sleep apnea and no unstable comorbidities. For patients suspected of having other types of sleep-disordered breathing or sleep disorders not related to breathing, level 1 testing remains the reference standard. PMID:24218531

  18. [Analysis on accuracy and influencing factors of oral fluid-based rapid HIV self-testing among men who have sex with men].

    PubMed

    Li, Youfang; Wang, Yumiao; Zhang, Renzhong; Wang, Jue; Li, Zhiqing; Wang, Ling; Pan, Songfeng; Yang, Yanling; Ma, Yanling; Jia, Manhong

    2016-01-01

    To understood the accuracy of oral fluid-based rapid HIV self-testing among men who have sex with men (MSM) and related factors. Survey was conducted among MSM selected through non-probability sampling to evaluate the quality of their rapid HIV self-testing, and related information was analyzed. The most MSM were aged 21-30 years (57.0%). Among them, 45.7% had educational level of college or above, 78.5% were unmarried, 59.3% were casual laborers. The overall accuracy rate of oral fluid based self-testing was 95.0%, the handling of"inserting test paper into tube as indicated by arrow on it"had the highest accuracy rate (98.0%), and the handling of"gently upsetting tube for 3 times"had lowest accuracy rate (65.0%); Chi-square analysis showed that educational level, no touch with middle part of test paper, whether reading the instruction carefully, whether understanding the instruction and inserting test paper into tube as indicated by the arrow on it were associated with the accuracy of oral fluid-based rapid HIV self-testing, (P<0.05). Multivariate logistic regression analysis indicated that educational level, no touch with middle part of test paper and understanding instructions were associated with the accuracy of oral fluid-based rapid HIV self-testing. The accuracy of oral fluid-based rapid HIV self-testing was high among MSM, the accuracy varied with the educational level of the MSM. Touch with the middle part of test paper or not and understanding the instructions or not might influence the accuracy of the self-testing.

  19. Accuracy of human papillomavirus testing on self-collected versus clinician-collected samples: a meta-analysis.

    PubMed

    Arbyn, Marc; Verdoodt, Freija; Snijders, Peter J F; Verhoef, Viola M J; Suonio, Eero; Dillner, Lena; Minozzi, Silvia; Bellisario, Cristina; Banzi, Rita; Zhao, Fang-Hui; Hillemanns, Peter; Anttila, Ahti

    2014-02-01

    Screening for human papillomavirus (HPV) infection is more effective in reducing the incidence of cervical cancer than screening using Pap smears. Moreover, HPV testing can be done on a vaginal sample self-taken by a woman, which offers an opportunity to improve screening coverage. However, the clinical accuracy of HPV testing on self-samples is not well-known. We assessed whether HPV testing on self-collected samples is equivalent to HPV testing on samples collected by clinicians. We identified relevant studies through a search of PubMed, Embase, and CENTRAL. Studies were eligible for inclusion if they fulfilled all of the following selection criteria: a cervical cell sample was self-collected by a woman followed by a sample taken by a clinician; a high-risk HPV test was done on the self-sample (index test) and HPV-testing or cytological interpretation was done on the specimen collected by the clinician (comparator tests); and the presence or absence of cervical intraepithelial neoplasia grade 2 (CIN2) or worse was verified by colposcopy and biopsy in all enrolled women or in women with one or more positive tests. The absolute accuracy for finding CIN2 or worse, or CIN grade 3 (CIN3) or worse of the index and comparator tests as well as the relative accuracy of the index versus the comparator tests were pooled using bivariate normal models and random effect models. We included data from 36 studies, which altogether enrolled 154 556 women. The absolute accuracy varied by clinical setting. In the context of screening, HPV testing on self-samples detected, on average, 76% (95% CI 69-82) of CIN2 or worse and 84% (72-92) of CIN3 or worse. The pooled absolute specificity to exclude CIN2 or worse was 86% (83-89) and 87% (84-90) to exclude CIN3 or worse. The variation of the relative accuracy of HPV testing on self-samples compared with tests on clinician-taken samples was low across settings, enabling pooling of the relative accuracy over all studies. The pooled sensitivity of HPV testing on self-samples was lower than HPV testing on a clinician-taken sample (ratio 0·88 [95% CI 0·85-0·91] for CIN2 or worse and 0·89 [0·83-0·96] for CIN3 or worse). Also specificity was lower in self-samples versus clinician-taken samples (ratio 0·96 [0·95-0·97] for CIN2 or worse and 0·96 [0·93-0·99] for CIN3 or worse). HPV testing with signal-based assays on self-samples was less sensitive and specific than testing on clinician-based samples. By contrast, some PCR-based HPV tests generally showed similar sensitivity on both self-samples and clinician-based samples. In screening programmes using signal-based assays, sampling by a clinician should be recommended. However, HPV testing on a self-sample can be suggested as an additional strategy to reach women not participating in the regular screening programme. Some PCR-based HPV tests could be considered for routine screening after careful piloting assessing feasibility, logistics, population compliance, and costs. The 7th Framework Programme of the European Commission, the Belgian Foundation against Cancer, the International Agency for Research on Cancer, and the German Guideline Program in Oncology. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Encoding Modality Can Affect Memory Accuracy via Retrieval Orientation

    ERIC Educational Resources Information Center

    Pierce, Benton H.; Gallo, David A.

    2011-01-01

    Research indicates that false memory is lower following visual than auditory study, potentially because visual information is more distinctive. In the present study we tested the extent to which retrieval orientation can cause a modality effect on memory accuracy. Participants studied unrelated words in different modalities, followed by criterial…

  1. The Discriminant Accuracy of a Grammatical Measure with Latino English-Speaking Children

    ERIC Educational Resources Information Center

    Gutierrez-Clellen, Vera F.; Simon-Cereijido, Gabriela

    2007-01-01

    Purpose: To evaluate the discriminant accuracy of a grammatical measure for the identification of language impairment (LI) in Latino English-speaking children. Specifically, the study examined the diagnostic accuracy of the Test of English Morphosyntax (E-MST; Pena, Gutierrez-Clellen, Iglesias, Goldstein, & Bedore (n.d.) to determine (a)…

  2. Extraversion/Introversion and Gender in Relation to the English Pronunciation Accuracy of Arabic Speaking College Students.

    ERIC Educational Resources Information Center

    Hassan, Badran A.

    The relationship between both extraversion/introversion and gender to the pronunciation accuracy of English as a foreign language was examined. Instruments for this study included a specifically developed introversion scale and an English language pronunciation accuracy test. Subjects were third-year English language specialists. It was found…

  3. Infrared Imagery of Shuttle (IRIS). Task 2, summary report

    NASA Technical Reports Server (NTRS)

    Chocol, C. J.

    1978-01-01

    End-to-end tests of a 16 element indium antimonide sensor array and 10 channels of associated electronic signal processing were completed. Quantitative data were gathered on system responsivity, frequency response, noise, stray capacitance effects, and sensor paralleling. These tests verify that the temperature accuracies, predicted in the Task 1 study, can be obtained with a very carefully designed electro-optical flight system. Pre-flight and inflight calibration of a high quality are mandatory to obtain these accuracies. Also, optical crosstalk in the array-dewar assembly must be carefully eliminated by its design. Tests of the scaled up tracking system reticle also demonstrate that the predicted tracking system accuracies can be met in the flight system. In addition, improvements in the reticle pattern and electronics are possible, which will reduce the complexity of the flight system and increase tracking accuracy.

  4. Grading evidence from test accuracy studies: what makes it challenging compared with the grading of effectiveness studies?

    PubMed

    Rogozińska, Ewelina; Khan, Khalid

    2017-06-01

    Guideline panels need to process a sizeable amount of information to issue a decision on whether to recommend a health technology or not. Grading of Recommendations Assessment, Development, and Evaluation (GRADE) is being frequently applied in guideline development to facilitate this task, typically for the synthesis of effectiveness research. Questions regarding the accuracy of medical tests are ubiquitous, and they temporally precede questions about therapy. However, literature summarising the experience of applying GRADE approach to accuracy evaluations is not as rich as one for effectiveness evidence. Type of study design (cross-sectional), two-dimensional nature of the performance measures (sensitivity and specificity), propensity towards a higher level of between-study heterogeneity, poor reporting of quality features and uncertainty about how best to assess for publication bias among other features make this task challenging. This article presents solutions adopted to addresses above challenges for judicious estimation of the strength of test accuracy evidence used to inform evidence syntheses for guideline development. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  5. Methods Used in Economic Evaluations of Testing and Diagnosis for Ovarian Cancer: A Systematic Review.

    PubMed

    Sharma, Vishal; Sundar, Sudha S; Breheny, Katie; Monahan, Mark; Sutton, Andrew John

    2016-06-01

    There are multiple tests available that can help diagnose ovarian cancer, and the cost-effective analysis of these diagnostic interventions is essential for making well-informed decisions regarding resource allocation. There are multiple factors that can impact on the conclusions drawn from economic evaluations including test accuracy, the impact of the testing pathway on patient costs and outcomes, and delays along the ovarian cancer test-treat pathway. The objective of this study was to evaluate how test accuracy, the choice of perspective, and delays along the testing and diagnostic pathway have been incorporated in economic evaluations of testing for ovarian cancer. A systematic review of published literature was undertaken to identify economic evaluations (eg, cost-effectiveness, cost-utility analysis) focused on testing and diagnosis for ovarian cancer. Seven studies met the inclusion criteria. Six studies incorporated test accuracy and its impact on patients to some extent. Four studies adopted a societal perspective, but only one considered the costs incurred by patients on the testing and diagnosis pathway. Where delays on the testing pathway were incorporated into the analysis, these were frequently due to false-negative test results leading to delays in patients accessing treatment. Any anxiety that patients might experience as a result of a positive test was not considered in these studies. The impact on patients of receiving a positive test in terms of anxiety and the costs incurred by patients having to attend for testing and diagnosis are rarely considered. Delays along the testing and diagnosis pathway can have a major effect on patient outcomes, and it is important that these are acknowledged in economic evaluations focused on testing. Future economic analysis should incorporate these key determinants in order that diagnostic tests for ovarian cancer can be robustly evaluated.

  6. Diagnostic accuracy of functional, imaging and biochemical tests for patients presenting with chest pain to the emergency department: A systematic review and meta-analysis.

    PubMed

    Iannaccone, Mario; Gili, Sebastiano; De Filippo, Ovidio; D'Amico, Salvatore; Gagliardi, Marco; Bertaina, Maurizio; Mazzilli, Silvia; Rettegno, Sara; Bongiovanni, Federica; Gatti, Paolo; Ugo, Fabrizio; Boccuzzi, Giacomo G; Colangelo, Salvatore; Prato, Silvia; Moretti, Claudio; D'Amico, Maurizio; Noussan, Patrizia; Garbo, Roberto; Hildick-Smith, David; Gaita, Fiorenzo; D'Ascenzo, Fabrizio

    2018-01-01

    Non-invasive ischaemia tests and biomarkers are widely adopted to rule out acute coronary syndrome in the emergency department. Their diagnostic accuracy has yet to be precisely defined. Medline, Cochrane Library CENTRAL, EMBASE and Biomed Central were systematically screened (start date 1 September 2016, end date 1 December 2016). Prospective studies (observational or randomised controlled trial) comparing functional/imaging or biochemical tests for patients presenting with chest pain to the emergency department were included. Overall, 77 studies were included, for a total of 49,541 patients (mean age 59.9 years). Fast and six-hour highly sensitive troponin T protocols did not show significant differences in their ability to detect acute coronary syndromes, as they reported a sensitivity and specificity of 0.89 (95% confidence interval 0.79-0.94) and 0.84 (0.74-0.9) vs 0.89 (0.78-0.94) and 0.83 (0.70-0.92), respectively. The addition of copeptin to troponin increased sensitivity and reduced specificity, without improving diagnostic accuracy. The diagnostic value of non-invasive tests for patients without troponin increase was tested. Coronary computed tomography showed the highest level of diagnostic accuracy (sensitivity 0.93 (0.81-0.98) and specificity 0.90 (0.93-0.94)), along with myocardial perfusion scintigraphy (sensitivity 0.85 (0.77-0.91) and specificity 0.92 (0.83-0.96)). Stress echography was inferior to coronary computed tomography but non-inferior to myocardial perfusion scintigraphy, while exercise testing showed the lower level of diagnostic accuracy. Fast and six-hour highly sensitive troponin T protocols provide an overall similar level of diagnostic accuracy to detect acute coronary syndrome. Among the non-invasive ischaemia tests for patients without troponin increase, coronary computed tomography and myocardial perfusion scintigraphy showed the highest sensitivity and specificity.

  7. Consumer preferences for the predictive genetic test for Alzheimer disease.

    PubMed

    Huang, Ming-Yi; Huston, Sally A; Perri, Matthew

    2014-04-01

    The purpose of this study was to assess consumer preferences for predictive genetic testing for Alzheimer disease in the United States. A rating conjoint analysis was conducted using an anonymous online survey distributed by Qualtrics to a general population panel in April 2011 in the United States. The study design included three attributes: Accuracy (40%, 80%, and 100%), Treatment Availability (Cure is available/Drug for symptom relief but no cure), and Anonymity (Anonymous/Not anonymous). A total of 12 scenarios were used to elicit people's preference, assessed by an 11-point scale. The respondents also indicated their highest willingness-to-pay (WTP) for each scenario through open-ended questions. A total of 295 responses were collected over 4 days. The most important attribute for the aggregate model was Accuracy, contributing 64.73% to the preference rating. Treatment Availability and Anonymity contributed 20.72% and 14.59%, respectively, to the preference rating. The median WTP for the highest-rating scenario (Accuracy 100%, a cure is available, test result is anonymous) was $100 (mean = $276). The median WTP for the lowest-rating scenario (40% accuracy, no cure but drugs for symptom relief, not anonymous) was zero (mean = $34). The results of this study highlight attributes people find important when making the hypothetical decision to obtain an AD genetic test. These results should be of interests to policy makers, genetic test developers and health care providers.

  8. PAX1 Methylation Hallmarks Promising Accuracy for Cervical Cancer Screening in Asians: Results from a Meta-Analysis.

    PubMed

    Kong, Ling-Ying; Du, Wei; Wang, Li; Yang, Zhi; Zhang, Hong-Sheng

    2015-01-01

    DNA methylation has been proposed as a potential biomarker for cervical cancer detection. This study aimed to evaluate the diagnostic role of paired boxed gene 1 (PAX1) methylation for cervical cancer screening in Asians. Eligible studies were retrieved by searching the electronic databases, and the quality of the enrolled studies was assessed via the quality assessment for studies of diagnostic accuracy (QUADAS) tool. The bivariate meta-analysis model was employed to generate the summary receiver operator characteristic (SROC) curve using Stata 12.0 software. Cochran's Q test and I2 statistics were applied to assess heterogeneity among studies. Publication bias was evaluated by the Deeks' funnel plot asymmetry test. A total of 9 articles containing 15 individual studies were included. The SROC analysis showed that single PAX1 methylation allowed for the discrimination between cancer/high-grade squamous intraepithelial lesion (HSIL) patients and normal individuals with a sensitivity (95% confidence interval) of 0.80 (0.70 - 0.87) and specificity of 0.89 (0.86 - 0.92), corresponding to an area under curve (AUC) of 0.92. Notably, our subgroup analysis suggested that combing parallel testing of PAX1 methylation and HPV DNA (AUC, sensitivity, and specificity of 0.90, 0.82, and 0.84, respectively) seemed to harbor higher accuracy than single HPV DNA testing (AUC, sensitivity, and specificity of 0.81, 0.86, and 0.67, respectively). PAX1 methylation hallmarks a potential diagnostic value for cervical cancer screening in Asians, and parallel testing of PAX1 methylation and HPV in cervical scrapings confers an improved accuracy than single HPV DNA testing.

  9. The Predictive Impact of Biological and Sociocultural Factors on Executive Processing: The Role of Age, Education, and Frequency of Reading and Writing Habits.

    PubMed

    Cotrena, Charles; Branco, Laura D; Cardoso, Caroline O; Wong, Cristina Elizabeth I; Fonseca, Rochele P

    2016-01-01

    Although the impact of education and age on executive functions (EF) has been widely studied, the influence of daily cognitive stimulation on EF has not been sufficiently investigated. Therefore, the aim of the present study was to evaluate whether the age, education, and frequency of reading and writing habits (FRWH) of healthy adults could predict their performance on measures of inhibition and cognitive flexibility. Inhibition speed, inhibitory control, and set shifting were assessed using speed, accuracy, and discrepancy scores on the Trail-Making Test (TMT) and Hayling Test. Demographic characteristics and the FRWH were assessed using specialized questionnaires. Regression analyses showed that age and the FRWH predicted speed and accuracy on the TMT. The FRWH predicted both speed and accuracy on the Hayling Test, for which speed and accuracy scores were also partly explained by age and education, respectively. Surprisingly, only the FRWH was associated with Hayling Test discrepancy scores, considered one of the purest EF measures. This highlights the importance of regular cognitive stimulation over the number of years of formal education on EF tasks. Further studies are required to investigate the role of the FRWH so as to better comprehend its relationship with EF and general cognition.

  10. An ROC-type measure of diagnostic accuracy when the gold standard is continuous-scale.

    PubMed

    Obuchowski, Nancy A

    2006-02-15

    ROC curves and summary measures of accuracy derived from them, such as the area under the ROC curve, have become the standard for describing and comparing the accuracy of diagnostic tests. Methods for estimating ROC curves rely on the existence of a gold standard which dichotomizes patients into disease present or absent. There are, however, many examples of diagnostic tests whose gold standards are not binary-scale, but rather continuous-scale. Unnatural dichotomization of these gold standards leads to bias and inconsistency in estimates of diagnostic accuracy. In this paper, we propose a non-parametric estimator of diagnostic test accuracy which does not require dichotomization of the gold standard. This estimator has an interpretation analogous to the area under the ROC curve. We propose a confidence interval for test accuracy and a statistical test for comparing accuracies of tests from paired designs. We compare the performance (i.e. CI coverage, type I error rate, power) of the proposed methods with several alternatives. An example is presented where the accuracies of two quick blood tests for measuring serum iron concentrations are estimated and compared.

  11. Bayesian Estimation of Combined Accuracy for Tests with Verification Bias

    PubMed Central

    Broemeling, Lyle D.

    2011-01-01

    This presentation will emphasize the estimation of the combined accuracy of two or more tests when verification bias is present. Verification bias occurs when some of the subjects are not subject to the gold standard. The approach is Bayesian where the estimation of test accuracy is based on the posterior distribution of the relevant parameter. Accuracy of two combined binary tests is estimated employing either “believe the positive” or “believe the negative” rule, then the true and false positive fractions for each rule are computed for two tests. In order to perform the analysis, the missing at random assumption is imposed, and an interesting example is provided by estimating the combined accuracy of CT and MRI to diagnose lung cancer. The Bayesian approach is extended to two ordinal tests when verification bias is present, and the accuracy of the combined tests is based on the ROC area of the risk function. An example involving mammography with two readers with extreme verification bias illustrates the estimation of the combined test accuracy for ordinal tests. PMID:26859487

  12. Diagnostic Accuracy Assessment of Sensititre and Agar Disk Diffusion for Determining Antimicrobial Resistance Profiles of Bovine Clinical Mastitis Pathogens▿

    PubMed Central

    Saini, V.; Riekerink, R. G. M. Olde; McClure, J. T.; Barkema, H. W.

    2011-01-01

    Determining the accuracy and precision of a measuring instrument is pertinent in antimicrobial susceptibility testing. This study was conducted to predict the diagnostic accuracy of the Sensititre MIC mastitis panel (Sensititre) and agar disk diffusion (ADD) method with reference to the manual broth microdilution test method for antimicrobial resistance profiling of Escherichia coli (n = 156), Staphylococcus aureus (n = 154), streptococcal (n = 116), and enterococcal (n = 31) bovine clinical mastitis isolates. The activities of ampicillin, ceftiofur, cephalothin, erythromycin, oxacillin, penicillin, the penicillin-novobiocin combination, pirlimycin, and tetracycline were tested against the isolates. Diagnostic accuracy was determined by estimating the area under the receiver operating characteristic curve; intertest essential and categorical agreements were determined as well. Sensititre and the ADD method demonstrated moderate to highly accurate (71 to 99%) and moderate to perfect (71 to 100%) predictive accuracies for 74 and 76% of the isolate-antimicrobial MIC combinations, respectively. However, the diagnostic accuracy was low for S. aureus-ceftiofur/oxacillin combinations and other streptococcus-ampicillin combinations by either testing method. Essential agreement between Sensititre automatic MIC readings and MIC readings obtained by the broth microdilution test method was 87%. Essential agreement between Sensititre automatic and manual MIC reading methods was 97%. Furthermore, the ADD test method and Sensititre MIC method exhibited 92 and 91% categorical agreement (sensitive, intermediate, resistant) of results, respectively, compared with the reference method. However, both methods demonstrated lower agreement for E. coli-ampicillin/cephalothin combinations than for Gram-positive isolates. In conclusion, the Sensititre and ADD methods had moderate to high diagnostic accuracy and very good essential and categorical agreement for most udder pathogen-antimicrobial combinations and can be readily employed in veterinary diagnostic laboratories. PMID:21270215

  13. Group Sequential Testing of the Predictive Accuracy of a Continuous Biomarker with Unknown Prevalence

    PubMed Central

    Koopmeiners, Joseph S.; Feng, Ziding

    2015-01-01

    Group sequential testing procedures have been proposed as an approach to conserving resources in biomarker validation studies. Previously, Koopmeiners and Feng (2011) derived the asymptotic properties of the sequential empirical positive predictive value (PPV) and negative predictive value curves, which summarize the predictive accuracy of a continuous marker, under case-control sampling. A limitation of their approach is that the prevalence can not be estimated from a case-control study and must be assumed known. In this manuscript, we consider group sequential testing of the predictive accuracy of a continuous biomarker with unknown prevalence. First, we develop asymptotic theory for the sequential empirical PPV and NPV curves when the prevalence must be estimated, rather than assumed known in a case-control study. We then discuss how our results can be combined with standard group sequential methods to develop group sequential testing procedures and bias-adjusted estimators for the PPV and NPV curve. The small sample properties of the proposed group sequential testing procedures and estimators are evaluated by simulation and we illustrate our approach in the context of a study to validate a novel biomarker for prostate cancer. PMID:26537180

  14. Accuracy of clinical neurological examination in diagnosing lumbo-sacral radiculopathy: a systematic literature review.

    PubMed

    Tawa, Nassib; Rhoda, Anthea; Diener, Ina

    2017-02-23

    Lumbar radiculopathy remains a clinical challenge among primary care clinicians in both assessment and diagnosis. This often leads to misdiagnosis and inappropriate treatment of patients resulting in poor health outcomes, exacerbating this already debilitating condition. This review evaluated 12 primary diagnostic accuracy studies that specifically assessed the performance of various individual and grouped clinical neurological tests in detecting nerve root impingement, as established in the current literature. Eight electronic data bases were searched for relevant articles from inception until July 2016. All primary diagnostic studies which investigated the accuracy of clinical neurological test (s) in diagnosing lumbar radiculopathy among patients with low back and referred leg symptoms were screened for inclusion. Qualifying studies were retrieved and independently assessed for methodological quality using the 'Quality Assessment of Diagnostic tests Accuracy Studies' criteria. A total of 12 studies which investigated standard components of clinical neurological examination of (sensory, motor, tendon reflex and neuro-dynamics) of the lumbo-sacral spine were included. The mean inter-observer agreement on quality assessment by two independent reviewers was fair (k = 0.3 - 0.7). The diagnostic performance of sensory testing using MR imaging as a reference standard demonstrated a sensitivity (confidence interval 95%) 0.61 (0.47-0.73) and a specificity of 0.63 (0.38-0.84). Motor tests sensitivity was poor to moderate, ranging from 0.13 (0.04-0.31) to 0.61 (0.36-0.83). Generally, the diagnostic performance of reflex testing was notably good with specificity ranging from (confidence interval 95%) 0.60 (0.51-0.69) to 0.93 (0.87-0.97) and sensitivity ranging from 0.14 (0.09-0.21) to 0.67 (0.21-0.94). Femoral nerve stretch test had a high sensitivity of (confidence interval 95%) 1.00 (0.40-1.00) and specificity of 0.83 (0.52-0.98) while SLR test recorded a mean sensitivity of 0.84 (0.72-0.92) and specificity of 0.78 (0.67-0.87). There is a scarcity of studies on the diagnostic accuracy of clinical neurological examination testing. Furthermore there seem to be a disconnect among researchers regarding the diagnostic utility of lower limb neuro-dynamic tests which include the Straight Leg Raise and Femoral Nerve tests for sciatic and femoral nerve respectively. Whether these tests are able to detect the presence of disc herniation and subsequent nerve root compression or hyper-sensitivity of the sacral and femoral plexus due to mechanical irritation still remains debatable.

  15. Accuracy Analysis for Finite-Volume Discretization Schemes on Irregular Grids

    NASA Technical Reports Server (NTRS)

    Diskin, Boris; Thomas, James L.

    2010-01-01

    A new computational analysis tool, downscaling test, is introduced and applied for studying the convergence rates of truncation and discretization errors of nite-volume discretization schemes on general irregular (e.g., unstructured) grids. The study shows that the design-order convergence of discretization errors can be achieved even when truncation errors exhibit a lower-order convergence or, in some cases, do not converge at all. The downscaling test is a general, efficient, accurate, and practical tool, enabling straightforward extension of verification and validation to general unstructured grid formulations. It also allows separate analysis of the interior, boundaries, and singularities that could be useful even in structured-grid settings. There are several new findings arising from the use of the downscaling test analysis. It is shown that the discretization accuracy of a common node-centered nite-volume scheme, known to be second-order accurate for inviscid equations on triangular grids, degenerates to first order for mixed grids. Alternative node-centered schemes are presented and demonstrated to provide second and third order accuracies on general mixed grids. The local accuracy deterioration at intersections of tangency and in flow/outflow boundaries is demonstrated using the DS tests tailored to examining the local behavior of the boundary conditions. The discretization-error order reduction within inviscid stagnation regions is demonstrated. The accuracy deterioration is local, affecting mainly the velocity components, but applies to any order scheme.

  16. Diagnosis of rotator cuff tears using 3-Tesla MRI versus 3-Tesla MRA: a systematic review and meta-analysis.

    PubMed

    McGarvey, Ciaran; Harb, Ziad; Smith, Christian; Houghton, Russell; Corbett, Steven; Ajuied, Adil

    2016-02-01

    To compare the diagnostic accuracy of magnetic resonance imaging (MRI), 2-dimensional magnetic resonance arthrogram (MRA) and 3-dimensional isotropic MRA in the diagnosis of rotator cuff tears when performed exclusively at 3-T. A systematic review was undertaken of the Cochrane, MEDLINE and PubMed databases in accordance with the PRISMA guidelines. Studies comparing 3-T MRI or 3-T MRA (index tests) to arthroscopic surgical findings (reference test) were included. Methodological appraisal was performed using QUADAS 2. Pooled sensitivity and specificity were calculated and summary receiver-operating curves generated. Kappa coefficients quantified inter-observer reliability. Fourteen studies comprising 1332 patients were identified for inclusion. Twelve studies were retrospective and there were concerns regarding index test bias and applicability in nine and six studies respectively. Reference test bias was a concern in all studies. Both 3-T MRI and 3-T MRA showed similar excellent diagnostic accuracy for full-thickness supraspinatus tears. Concerning partial-thickness supraspinatus tears, 3-T 2D MRA was significantly more sensitive (86.6 vs. 80.5 %, p = 0.014) but significantly less specific (95.2 vs. 100 %, p < 0.001). There was a trend towards greater accuracy in the diagnosis of subscapularis tears with 3-T MRA. Three-Tesla 3D isotropic MRA showed similar accuracy to 3-T conventional 2D MRA. Three-Tesla MRI appeared equivalent to 3-T MRA in the diagnosis of full- and partial-thickness tears, although there was a trend towards greater accuracy in the diagnosis of subscapularis tears with 3-T MRA. Three-Tesla 3D isotropic MRA appears equivalent to 3-T 2D MRA for all types of tears.

  17. Ensemble coding remains accurate under object and spatial visual working memory load.

    PubMed

    Epstein, Michael L; Emmanouil, Tatiana A

    2017-10-01

    A number of studies have provided evidence that the visual system statistically summarizes large amounts of information that would exceed the limitations of attention and working memory (ensemble coding). However the necessity of working memory resources for ensemble coding has not yet been tested directly. In the current study, we used a dual task design to test the effect of object and spatial visual working memory load on size averaging accuracy. In Experiment 1, we tested participants' accuracy in comparing the mean size of two sets under various levels of object visual working memory load. Although the accuracy of average size judgments depended on the difference in mean size between the two sets, we found no effect of working memory load. In Experiment 2, we tested the same average size judgment while participants were under spatial visual working memory load, again finding no effect of load on averaging accuracy. Overall our results reveal that ensemble coding can proceed unimpeded and highly accurately under both object and spatial visual working memory load, providing further evidence that ensemble coding reflects a basic perceptual process distinct from that of individual object processing.

  18. Diagnostic accuracy of clinical illness for bovine respiratory disease (BRD) diagnosis in beef cattle placed in feedlots: A systematic literature review and hierarchical Bayesian latent-class meta-analysis.

    PubMed

    Timsit, E; Dendukuri, N; Schiller, I; Buczinski, S

    2016-12-01

    Diagnosis of bovine respiratory disease (BRD) in beef cattle placed in feedlots is typically based on clinical illness (CI) detected by pen-checkers. Unfortunately, the accuracy of this diagnostic approach (namely, sensitivity [Se] and specificity [Sp]) remains poorly understood, in part due to the absence of a reference test for ante-mortem diagnosis of BRD. Our objective was to pool available estimates of CI's diagnostic accuracy for BRD diagnosis in feedlot beef cattle while adjusting for the inaccuracy in the reference test. The presence of lung lesions (LU) at slaughter was used as the reference test. A systematic review of the literature was conducted to identify research articles comparing CI detected by pen-checkers during the feeding period to LU at slaughter. A hierarchical Bayesian latent-class meta-analysis was used to model test accuracy. This approach accounted for imperfections of both tests as well as the within and between study variability in the accuracy of CI. Furthermore, it also predicted the Se CI and Sp CI for future studies. Conditional independence between CI and LU was assumed, as these two tests are not based on similar biological principles. Seven studies were included in the meta-analysis. Estimated pooled Se CI and Sp CI were 0.27 (95% Bayesian credible interval: 0.12-0.65) and 0.92 (0.72-0.98), respectively, whereas estimated pooled Se LU and Sp LU were 0.91 (0.82-0.99) and 0.67 (0.64-0.79). Predicted Se CI and Sp CI for future studies were 0.27 (0.01-0.96) and 0.92 (0.14-1.00), respectively. The wide credible intervals around predicted Se CI and Sp CI estimates indicated considerable heterogeneity among studies, which suggests that pooled Se CI and Sp CI are not generalizable to individual studies. In conclusion, CI appeared to have poor Se but high Sp for BRD diagnosis in feedlots. Furthermore, considerable heterogeneity among studies highlighted an urgent need to standardize BRD diagnosis in feedlots. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. The Use of Linear Programming for Prediction.

    ERIC Educational Resources Information Center

    Schnittjer, Carl J.

    The purpose of the study was to develop a linear programming model to be used for prediction, test the accuracy of the predictions, and compare the accuracy with that produced by curvilinear multiple regression analysis. (Author)

  20. Five common tumor biomarkers and CEA for diagnosing early gastric cancer: A protocol for a network meta-analysis of diagnostic test accuracy.

    PubMed

    Shen, Minghui; Wang, Hui; Wei, Kongyuan; Zhang, Jianling; You, Chongge

    2018-05-01

    Although surgical resection is the recommended treatment for the patients with gastric cancer, lots of patients show advanced or metastatic gastric cancer at the time of diagnosis. Detection of gastric cancer at early stages is a huge challenge because of lack of appropriate detection tests. Unfortunately, existing clinical guidelines focusing on early diagnosis of gastric cancer do not provide consistent and prudent evidence. Serum carcinoembryonic antigen was considered as a complementary test, although it is not good enough to diagnose early gastric cancer. There are no other tumor markers recommended for diagnosing early gastric cancer. This study aims to evaluate and compare the diagnostic accuracy of 5 common tumor biomarkers (CA19-9, CA125, PG, IncRNA, and DNA methylation) and CEA and their combinations for diagnosing gastric cancer through network meta-analysis method, and to rank these tests using a superiority index. PubMed, EMBASE.com, and the Cochrane Central Register of Controlled Trials (CENTRAL) will be searched from their inception to March 2018. We will include diagnostic tests which assessed the accuracy of the above-mentioned tumor biomarkers and CEA for diagnosing gastric cancer. The risk of bias for each study will be independently assessed as low, moderate, or high using criteria adapted from Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2). Network meta-analysis will be performed using STATA 12.0 and R 3.4.1 software. The competing diagnostic tests will be ranked by a superiority index. This study is ongoing and will be submitted to a peer-reviewed journal for publication. This study will provide systematically suggestions to select different tumor biomarkers for detecting the early gastric cancer.

  1. 40 CFR 53.53 - Test for flow rate accuracy, regulation, measurement accuracy, and cut-off.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., measurement accuracy, and cut-off. 53.53 Section 53.53 Protection of Environment ENVIRONMENTAL PROTECTION..., measurement accuracy, and cut-off. (a) Overview. This test procedure is designed to evaluate a candidate... measurement accuracy, coefficient of variability measurement accuracy, and the flow rate cut-off function. The...

  2. A vine copula mixed effect model for trivariate meta-analysis of diagnostic test accuracy studies accounting for disease prevalence.

    PubMed

    Nikoloulopoulos, Aristidis K

    2017-10-01

    A bivariate copula mixed model has been recently proposed to synthesize diagnostic test accuracy studies and it has been shown that it is superior to the standard generalized linear mixed model in this context. Here, we call trivariate vine copulas to extend the bivariate meta-analysis of diagnostic test accuracy studies by accounting for disease prevalence. Our vine copula mixed model includes the trivariate generalized linear mixed model as a special case and can also operate on the original scale of sensitivity, specificity, and disease prevalence. Our general methodology is illustrated by re-analyzing the data of two published meta-analyses. Our study suggests that there can be an improvement on trivariate generalized linear mixed model in fit to data and makes the argument for moving to vine copula random effects models especially because of their richness, including reflection asymmetric tail dependence, and computational feasibility despite their three dimensionality.

  3. Investigating the spatial accuracy of CBCT-guided cranial radiosurgery: A phantom end-to-end test study.

    PubMed

    Calvo-Ortega, Juan-Francisco; Hermida-López, Marcelino; Moragues-Femenía, Sandra; Pozo-Massó, Miquel; Casals-Farran, Joan

    2017-03-01

    To evaluate the spatial accuracy of a frameless cone-beam computed tomography (CBCT)-guided cranial radiosurgery (SRS) using an end-to-end (E2E) phantom test methodology. Five clinical SRS plans were mapped to an acrylic phantom containing a radiochromic film. The resulting phantom-based plans (E2E plans) were delivered four times. The phantom was setup on the treatment table with intentional misalignments, and CBCT-imaging was used to align it prior to E2E plan delivery. Comparisons (global gamma analysis) of the planned and delivered dose to the film were performed using a commercial triple-channel film dosimetry software. The necessary distance-to-agreement to achieve a 95% (DTA95) gamma passing rate for a fixed 3% dose difference provided an estimate of the spatial accuracy of CBCT-guided SRS. Systematic (∑) and random (σ) error components, as well as 95% confidence levels were derived for the DTA95 metric. The overall systematic spatial accuracy averaged over all tests was 1.4mm (SD: 0.2mm), with a corresponding 95% confidence level of 1.8mm. The systematic (Σ) and random (σ) spatial components of the accuracy derived from the E2E tests were 0.2mm and 0.8mm, respectively. The E2E methodology used in this study allowed an estimation of the spatial accuracy of our CBCT-guided SRS procedure. Subsequently, a PTV margin of 2.0mm is currently used in our department. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  4. Effects of Emotion on Associative Recognition: Valence and Retention Interval Matter

    PubMed Central

    Pierce, Benton H.; Kensinger, Elizabeth A.

    2011-01-01

    In two experiments, we examined the effects of emotional valence and arousal on associative binding. Participants studied negative, positive, and neutral word pairs, followed by an associative recognition test. In Experiment 1, with a short-delayed test, accuracy for intact pairs was equivalent across valences, whereas accuracy for rearranged pairs was lower for negative than for positive and neutral pairs. In Experiment 2, we tested participants after a one-week delay and found that accuracy was greater for intact negative than for intact neutral pairs, whereas rearranged pair accuracy was equivalent across valences. These results suggest that, although negative emotional valence impairs associative binding after a short delay, it may improve binding after a longer delay. The results also suggest that valence, as well as arousal, needs to be considered when examining the effects of emotion on associative memory. PMID:21401233

  5. Quality control procedures for dynamic treatment delivery techniques involving couch motion.

    PubMed

    Yu, Victoria Y; Fahimian, Benjamin P; Xing, Lei; Hristov, Dimitre H

    2014-08-01

    In this study, the authors introduce and demonstrate quality control procedures for evaluating the geometric and dosimetric fidelity of dynamic treatment delivery techniques involving treatment couch motion synchronous with gantry and multileaf collimator (MLC). Tests were designed to evaluate positional accuracy, velocity constancy and accuracy for dynamic couch motion under a realistic weight load. A test evaluating the geometric accuracy of the system in delivering treatments over complex dynamic trajectories was also devised. Custom XML scripts that control the Varian TrueBeam™ STx (Serial #3) axes in Developer Mode were written to implement the delivery sequences for the tests. Delivered dose patterns were captured with radiographic film or the electronic portal imaging device. The couch translational accuracy in dynamic treatment mode was 0.01 cm. Rotational accuracy was within 0.3°, with 0.04 cm displacement of the rotational axis. Dose intensity profiles capturing the velocity constancy and accuracy for translations and rotation exhibited standard deviation and maximum deviations below 3%. For complex delivery involving MLC and couch motions, the overall translational accuracy for reproducing programmed patterns was within 0.06 cm. The authors conclude that in Developer Mode, TrueBeam™ is capable of delivering dynamic treatment delivery techniques involving couch motion with good geometric and dosimetric fidelity.

  6. Is there sufficient evidence for tuning fork tests in diagnosing fractures? A systematic review.

    PubMed

    Mugunthan, Kayalvili; Doust, Jenny; Kurz, Bodo; Glasziou, Paul

    2014-08-04

    To determine the diagnostic accuracy of tuning fork tests for detecting fractures. Systematic review of primary studies evaluating the diagnostic accuracy of tuning fork tests for the presence of fracture. We searched MEDLINE, CINAHL, AMED, EMBASE, Sports Discus, CAB Abstracts and Web of Science from commencement to November 2012. We manually searched the reference lists of any review papers and any identified relevant studies. Two reviewers independently reviewed the list of potentially eligible studies and rated the studies for quality using the QUADAS-2 tool. Data were extracted to form 2×2 contingency tables. The primary outcome measure was the accuracy of the test as measured by its sensitivity and specificity with 95% CIs. We included six studies (329 patients), with two types of tuning fork tests (pain induction and loss of sound transmission). The studies included patients with an age range 7-60 years. The prevalence of fracture ranged from 10% to 80%. The sensitivity of the tuning fork tests was high, ranging from 75% to 100%. The specificity of the tests was highly heterogeneous, ranging from 18% to 95%. Based on the studies in this review, tuning fork tests have some value in ruling out fractures, but are not sufficiently reliable or accurate for widespread clinical use. The small sample size of the studies and the observed heterogeneity make generalisable conclusion difficult. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  7. Adherence to Standards for Reporting Diagnostic Accuracy in Emergency Medicine Research.

    PubMed

    Gallo, Lucas; Hua, Nadia; Mercuri, Mathew; Silveira, Angela; Worster, Andrew

    2017-08-01

    Diagnostic tests are used frequently in the emergency department (ED) to guide clinical decision making and, hence, influence clinical outcomes. The Standards for Reporting of Diagnostic Accuracy (STARD) criteria were developed to ensure that diagnostic test studies are performed and reported to best inform clinical decision making in the ED. The objective was to determine the extent to which diagnostic studies published in emergency medicine journals adhered to STARD 2003 criteria. Diagnostic studies published in eight MEDLINE-listed, peer-reviewed, emergency medicine journals over a 5-year period were reviewed for compliance to STARD criteria. A total of 12,649 articles were screened and 114 studies were included in our study. Twenty percent of these were randomly selected for assessment using STARD 2003 criteria. Adherence to STARD 2003 reporting standards for each criteria ranged from 8.7% adherence (criteria-reporting adverse events from performing index test or reference standard) to 100% (multiple criteria). Just over half of STARD criteria are reported in more than 80% studies. As poorly reported studies may negatively impact their clinical usefulness, it is essential that studies of diagnostic test accuracy be performed and reported adequately. Future studies should assess whether studies have improved compliance with the STARD 2015 criteria amendment. © 2017 by the Society for Academic Emergency Medicine.

  8. Comparison of Feature Selection Techniques in Machine Learning for Anatomical Brain MRI in Dementia.

    PubMed

    Tohka, Jussi; Moradi, Elaheh; Huttunen, Heikki

    2016-07-01

    We present a comparative split-half resampling analysis of various data driven feature selection and classification methods for the whole brain voxel-based classification analysis of anatomical magnetic resonance images. We compared support vector machines (SVMs), with or without filter based feature selection, several embedded feature selection methods and stability selection. While comparisons of the accuracy of various classification methods have been reported previously, the variability of the out-of-training sample classification accuracy and the set of selected features due to independent training and test sets have not been previously addressed in a brain imaging context. We studied two classification problems: 1) Alzheimer's disease (AD) vs. normal control (NC) and 2) mild cognitive impairment (MCI) vs. NC classification. In AD vs. NC classification, the variability in the test accuracy due to the subject sample did not vary between different methods and exceeded the variability due to different classifiers. In MCI vs. NC classification, particularly with a large training set, embedded feature selection methods outperformed SVM-based ones with the difference in the test accuracy exceeding the test accuracy variability due to the subject sample. The filter and embedded methods produced divergent feature patterns for MCI vs. NC classification that suggests the utility of the embedded feature selection for this problem when linked with the good generalization performance. The stability of the feature sets was strongly correlated with the number of features selected, weakly correlated with the stability of classification accuracy, and uncorrelated with the average classification accuracy.

  9. Learning Linear Spatial-Numeric Associations Improves Accuracy of Memory for Numbers

    PubMed Central

    Thompson, Clarissa A.; Opfer, John E.

    2016-01-01

    Memory for numbers improves with age and experience. One potential source of improvement is a logarithmic-to-linear shift in children’s representations of magnitude. To test this, Kindergartners and second graders estimated the location of numbers on number lines and recalled numbers presented in vignettes (Study 1). Accuracy at number-line estimation predicted memory accuracy on a numerical recall task after controlling for the effect of age and ability to approximately order magnitudes (mapper status). To test more directly whether linear numeric magnitude representations caused improvements in memory, half of children were given feedback on their number-line estimates (Study 2). As expected, learning linear representations was again linked to memory for numerical information even after controlling for age and mapper status. These results suggest that linear representations of numerical magnitude may be a causal factor in development of numeric recall accuracy. PMID:26834688

  10. Learning Linear Spatial-Numeric Associations Improves Accuracy of Memory for Numbers.

    PubMed

    Thompson, Clarissa A; Opfer, John E

    2016-01-01

    Memory for numbers improves with age and experience. One potential source of improvement is a logarithmic-to-linear shift in children's representations of magnitude. To test this, Kindergartners and second graders estimated the location of numbers on number lines and recalled numbers presented in vignettes (Study 1). Accuracy at number-line estimation predicted memory accuracy on a numerical recall task after controlling for the effect of age and ability to approximately order magnitudes (mapper status). To test more directly whether linear numeric magnitude representations caused improvements in memory, half of children were given feedback on their number-line estimates (Study 2). As expected, learning linear representations was again linked to memory for numerical information even after controlling for age and mapper status. These results suggest that linear representations of numerical magnitude may be a causal factor in development of numeric recall accuracy.

  11. Diagnostic accuracy of serological diagnosis of hepatitis C and B using dried blood spot samples (DBS): two systematic reviews and meta-analyses.

    PubMed

    Lange, Berit; Cohn, Jennifer; Roberts, Teri; Camp, Johannes; Chauffour, Jeanne; Gummadi, Nina; Ishizaki, Azumi; Nagarathnam, Anupriya; Tuaillon, Edouard; van de Perre, Philippe; Pichler, Christine; Easterbrook, Philippa; Denkinger, Claudia M

    2017-11-01

    Dried blood spots (DBS) are a convenient tool to enable diagnostic testing for viral diseases due to transport, handling and logistical advantages over conventional venous blood sampling. A better understanding of the performance of serological testing for hepatitis C (HCV) and hepatitis B virus (HBV) from DBS is important to enable more widespread use of this sampling approach in resource limited settings, and to inform the 2017 World Health Organization (WHO) guidance on testing for HBV/HCV. We conducted two systematic reviews and meta-analyses on the diagnostic accuracy of HCV antibody (HCV-Ab) and HBV surface antigen (HBsAg) from DBS samples compared to venous blood samples. MEDLINE, EMBASE, Global Health and Cochrane library were searched for studies that assessed diagnostic accuracy with DBS and agreement between DBS and venous sampling. Heterogeneity of results was assessed and where possible a pooled analysis of sensitivity and specificity was performed using a bivariate analysis with maximum likelihood estimate and 95% confidence intervals (95%CI). We conducted a narrative review on the impact of varying storage conditions or limits of detection in subsets of samples. The QUADAS-2 tool was used to assess risk of bias. For the diagnostic accuracy of HBsAg from DBS compared to venous blood, 19 studies were included in a quantitative meta-analysis, and 23 in a narrative review. Pooled sensitivity and specificity were 98% (95%CI:95%-99%) and 100% (95%CI:99-100%), respectively. For the diagnostic accuracy of HCV-Ab from DBS, 19 studies were included in a pooled quantitative meta-analysis, and 23 studies were included in a narrative review. Pooled estimates of sensitivity and specificity were 98% (CI95%:95-99) and 99% (CI95%:98-100), respectively. Overall quality of studies and heterogeneity were rated as moderate in both systematic reviews. HCV-Ab and HBsAg testing using DBS compared to venous blood sampling was associated with excellent diagnostic accuracy. However, generalizability is limited as no uniform protocol was applied and most studies did not use fresh samples. Future studies on diagnostic accuracy should include an assessment of impact of environmental conditions common in low resource field settings. Manufacturers also need to formally validate their assays for DBS for use with their commercial assays.

  12. Comparative Diagnostic Accuracy of the ACE-III, MIS, MMSE, MoCA, and RUDAS for Screening of Alzheimer Disease.

    PubMed

    Matías-Guiu, Jordi A; Valles-Salgado, María; Rognoni, Teresa; Hamre-Gil, Frank; Moreno-Ramos, Teresa; Matías-Guiu, Jorge

    2017-01-01

    Our aim was to evaluate and compare the diagnostic properties of 5 screening tests for the diagnosis of mild Alzheimer disease (AD). We conducted a prospective and cross-sectional study of 92 patients with mild AD and of 68 healthy controls from our Department of Neurology. The diagnostic properties of the following tests were compared: Mini-Mental State Examination (MMSE), Addenbrooke's Cognitive Examination III (ACE-III), Memory Impairment Screen (MIS), Montreal Cognitive Assessment (MoCA), and Rowland Universal Dementia Assessment Scale (RUDAS). All tests yielded high diagnostic accuracy, with the ACE-III achieving the best diagnostic properties. The area under the curve was 0.897 for the ACE-III, 0.889 for the RUDAS, 0.874 for the MMSE, 0.866 for the MIS, and 0.856 for the MoCA. The Mini-ACE score from the ACE-III showed the highest diagnostic capacity (area under the curve 0.939). Memory scores of the ACE-III and of the RUDAS showed a better diagnostic accuracy than those of the MMSE and of the MoCA. All tests, especially the ACE-III, conveyed a higher diagnostic accuracy in patients with full primary education than in the less educated group. Implementing normative data improved the diagnostic accuracy of the ACE-III but not that of the other tests. The ACE-III achieved the highest diagnostic accuracy. This better discrimination was more evident in the more educated group. © 2017 S. Karger AG, Basel.

  13. Reporting completeness and transparency of meta-analyses of depression screening tool accuracy: A comparison of meta-analyses published before and after the PRISMA statement.

    PubMed

    Rice, Danielle B; Kloda, Lorie A; Shrier, Ian; Thombs, Brett D

    2016-08-01

    Meta-analyses that are conducted rigorously and reported completely and transparently can provide accurate evidence to inform the best possible healthcare decisions. Guideline makers have raised concerns about the utility of existing evidence on the diagnostic accuracy of depression screening tools. The objective of our study was to evaluate the transparency and completeness of reporting in meta-analyses of the diagnostic accuracy of depression screening tools using the PRISMA tool adapted for diagnostic test accuracy meta-analyses. We searched MEDLINE and PsycINFO from January 1, 2005 through March 13, 2016 for recent meta-analyses in any language on the diagnostic accuracy of depression screening tools. Two reviewers independently assessed the transparency in reporting using the PRISMA tool with appropriate adaptations made for studies of diagnostic test accuracy. We identified 21 eligible meta-analyses. Twelve of 21 meta-analyses complied with at least 50% of adapted PRISMA items. Of 30 adapted PRISMA items, 11 were fulfilled by ≥80% of included meta-analyses, 3 by 50-79% of meta-analyses, 7 by 25-45% of meta-analyses, and 9 by <25%. On average, post-PRISMA meta-analyses complied with 17 of 30 items compared to 13 of 30 items pre-PRISMA. Deficiencies in the transparency of reporting in meta-analyses of the diagnostic test accuracy of depression screening tools of meta-analyses were identified. Authors, reviewers, and editors should adhere to the PRISMA statement to improve the reporting of meta-analyses of the diagnostic accuracy of depression screening tools. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. English Verb Accuracy of Bilingual Cantonese-English Preschoolers.

    PubMed

    Rezzonico, Stefano; Goldberg, Ahuva; Milburn, Trelani; Belletti, Adriana; Girolametto, Luigi

    2017-07-26

    Knowledge of verb development in typically developing bilingual preschoolers may inform clinicians about verb accuracy rates during the 1st 2 years of English instruction. This study aimed to investigate tensed verb accuracy in 2 assessment contexts in 4- and 5-year-old Cantonese-English bilingual preschoolers. The sample included 47 Cantonese-English bilinguals enrolled in English preschools. Half of the children were in their 1st 4 months of English language exposure, and half had completed 1 year and 4 months of exposure to English. Data were obtained from the Test of Early Grammatical Impairment (Rice & Wexler, 2001) and from a narrative generated in English. By the 2nd year of formal exposure to English, children in the present study approximated 33% accuracy of tensed verbs in a formal testing context versus 61% in a narrative context. The use of the English verb BE approximated mastery. Predictors of English third-person singular verb accuracy were task, grade, English expressive vocabulary, and lemma frequency. Verb tense accuracy was low across both groups, but a precocious mastery of BE was observed. The results of the present study suggest that speech-language pathologists may consider, in addition to an elicitation task, evaluating the use of verbs during narratives in bilingual Cantonese-English bilingual children.

  15. Accuracy and reliability of peer assessment of athletic training psychomotor laboratory skills.

    PubMed

    Marty, Melissa C; Henning, Jolene M; Willse, John T

    2010-01-01

    Peer assessment is defined as students judging the level or quality of a fellow student's understanding. No researchers have yet demonstrated the accuracy or reliability of peer assessment in athletic training education. To determine the accuracy and reliability of peer assessment of athletic training students' psychomotor skills. Cross-sectional study. Entry-level master's athletic training education program. First-year (n  =  5) and second-year (n  =  8) students. Participants evaluated 10 videos of a peer performing 3 psychomotor skills (middle deltoid manual muscle test, Faber test, and Slocum drawer test) on 2 separate occasions using a valid assessment tool. Accuracy of each peer-assessment score was examined through percentage correct scores. We used a generalizability study to determine how reliable athletic training students were in assessing a peer performing the aforementioned skills. Decision studies using generalizability theory demonstrated how the peer-assessment scores were affected by the number of participants and number of occasions. Participants had a high percentage of correct scores: 96.84% for the middle deltoid manual muscle test, 94.83% for the Faber test, and 97.13% for the Slocum drawer test. They were not able to reliably assess a peer performing any of the psychomotor skills on only 1 occasion. However, the φ increased (exceeding the 0.70 minimal standard) when 2 participants assessed the skill on 3 occasions (φ  =  0.79) for the Faber test, with 1 participant on 2 occasions (φ  =  0.76) for the Slocum drawer test, and with 3 participants on 2 occasions for the middle deltoid manual muscle test (φ  =  0.72). Although students did not detect all errors, they assessed their peers with an average of 96% accuracy. Having only 1 student assess a peer performing certain psychomotor skills was less reliable than having more than 1 student assess those skills on more than 1 occasion. Peer assessment of psychomotor skills could be an important part of the learning process and a tool to supplement instructor assessment.

  16. Results of a remote multiplexer/digitizer unit accuracy and environmental study

    NASA Technical Reports Server (NTRS)

    Wilner, D. O.

    1977-01-01

    A remote multiplexer/digitizer unit (RMDU), a part of the airborne integrated flight test data system, was subjected to an accuracy study. The study was designed to show the effects of temperature, altitude, and vibration on the RMDU. The RMDU was subjected to tests at temperatures from -54 C (-65 F) to 71 C (160 F), and the resulting data are presented here, along with a complete analysis of the effects. The methods and means used for obtaining correctable data and correcting the data are also discussed.

  17. Assessing Giftedness in Children: Comparing the Accuracy of Three Shortened Measures of Intelligence to the Stanford-Binet Intelligence Scales, Fifth Edition

    ERIC Educational Resources Information Center

    Newton, Jocelyn H.; McIntosh, David E.; Dixon, Felicia; Williams, Tasha; Youman, Elizabeth

    2008-01-01

    This study examined the accuracy of three shortened measures of intelligence: the Woodcock-Johnson Tests of Cognitive Ability, Third Edition Brief Intellectual Ability (WJ III COG BIA) score; the Stanford-Binet Intelligence Scale, Fifth Edition Abbreviated IQ (SB5 ABIQ); and the Kaufman Brief Intelligence Test IQ Composite (K-BIT) in predicting…

  18. Concurrent Validity and Diagnostic Accuracy of the Dynamic Indicators of Basic Early Literacy Skills and the Comprehensive Test of Phonological Processing

    ERIC Educational Resources Information Center

    Hintze, John M.; Ryan, Amanda L.; Stoner, Gary

    2003-01-01

    The purpose of this study was to (a) examine the concurrent validity of the Dynamic Indicators of Basic Early Literacy Skills (DIBELS) with the Comprehensive Test of Phonological Processing (CTOPP), and (b) explore the diagnostic accuracy of the DIBELS in predicting CTOPP performance using suggested and alternative cut-scores. Eighty-six students…

  19. Systematic review of the accuracy of the ParaSight-F test in the diagnosis of Plasmodium falciparum malaria.

    PubMed

    Cruciani, Mario; Nardi, Stefano; Malena, Marina; Bosco, Oliviero; Serpelloni, Giovanni; Mengoli, Carlo

    2004-07-01

    The Parasight-F test is a device for the rapid diagnosis of Plasmodium falciparum malaria. In a number of field studies rather wide disparities in the performance of the test have been reported. To provide an evaluation of the quality of available reports and an overall summary of diagnostic accuracy of the Parasight-F test, we have performed a systematic review. Systematic review and meta-analysis of controlled studies evaluating the diagnostic accuracy of Parasight-F test in comparison with light microscopy. 15,359 subjects (4,119 with falciparum malaria) studied with the Parasight-F test as reported in 32 studies from 29 publications. Summary receiving operator characteristic (SROC) curve as well as odds ratio calculated by the fixed effect model and the random effect model. Based on pooled data, the predictive values were calculated for a range of P. falciparum prevalence through a Bayesian approach. Overall, the Parasight-F test demonstrated 0.90 (95%, confidence intervals 0.88-0.93) sensitivity and 0.94 (0.92-0.96) specificity. Both sensitivity and specificity were significantly higher in the non-resident than in the resident population. The post-test probability indicates that in settings of low malaria prevalence, a negative test almost absolutely excludes infection, while in settings of high prevalence, the same result still gives a substantial chance of infection being present. The Parasight-F test is a simple and accurate test for the diagnosis of P. falciparum infection. The test could be of particular value in the diagnosis of malaria in travelers returning from endemic areas.

  20. A Meta-Analysis of the Impact of Short-Term Sleep Deprivation on Cognitive Variables

    PubMed Central

    Lim, Julian; Dinges, David F.

    2012-01-01

    A substantial amount of research has been conducted in an effort to understand the impact of short-term (<48 hr) total sleep deprivation (SD) on outcomes in various cognitive domains. Despite this wealth of information, there has been disagreement on how these data should be interpreted, arising in part because the relative magnitude of effect sizes in these domains is not known. To address this question, we conducted a meta-analysis to discover the effects of short-term SD on both speed and accuracy measures in 6 cognitive categories: simple attention, complex attention, working memory, processing speed, short-term memory, and reasoning. Seventy articles containing 147 cognitive tests were found that met inclusion criteria for this study. Effect sizes ranged from small and nonsignificant (reasoning accuracy: ḡ = −0.125, 95% CI [−0.27, 0.02]) to large (lapses in simple attention: ḡ = −0.776, 95% CI [−0.96, −0.60], p < .001). Across cognitive domains, significant differences were observed for both speed and accuracy; however, there were no differences between speed and accuracy measures within each cognitive domain. Of several moderators tested, only time awake was a significant predictor of between-studies variability, and only for accuracy measures, suggesting that heterogeneity in test characteristics may account for a significant amount of the remaining between-studies variance. The theoretical implications of these findings for the study of SD and cognition are discussed. PMID:20438143

  1. A meta-analysis of the impact of short-term sleep deprivation on cognitive variables.

    PubMed

    Lim, Julian; Dinges, David F

    2010-05-01

    A substantial amount of research has been conducted in an effort to understand the impact of short-term (<48 hr) total sleep deprivation (SD) on outcomes in various cognitive domains. Despite this wealth of information, there has been disagreement on how these data should be interpreted, arising in part because the relative magnitude of effect sizes in these domains is not known. To address this question, we conducted a meta-analysis to discover the effects of short-term SD on both speed and accuracy measures in 6 cognitive categories: simple attention, complex attention, working memory, processing speed, short-term memory, and reasoning. Seventy articles containing 147 cognitive tests were found that met inclusion criteria for this study. Effect sizes ranged from small and nonsignificant (reasoning accuracy: g = -0.125, 95% CI [-0.27, 0.02]) to large (lapses in simple attention: g = -0.776, 95% CI [-0.96, -0.60], p < .001). Across cognitive domains, significant differences were observed for both speed and accuracy; however, there were no differences between speed and accuracy measures within each cognitive domain. Of several moderators tested, only time awake was a significant predictor of between-studies variability, and only for accuracy measures, suggesting that heterogeneity in test characteristics may account for a significant amount of the remaining between-studies variance. The theoretical implications of these findings for the study of SD and cognition are discussed. (c) 2010 APA, all rights reserved.

  2. The Relationship Between Eyewitness Confidence and Identification Accuracy: A New Synthesis.

    PubMed

    Wixted, John T; Wells, Gary L

    2017-05-01

    The U.S. legal system increasingly accepts the idea that the confidence expressed by an eyewitness who identified a suspect from a lineup provides little information as to the accuracy of that identification. There was a time when this pessimistic assessment was entirely reasonable because of the questionable eyewitness-identification procedures that police commonly employed. However, after more than 30 years of eyewitness-identification research, our understanding of how to properly conduct a lineup has evolved considerably, and the time seems ripe to ask how eyewitness confidence informs accuracy under more pristine testing conditions (e.g., initial, uncontaminated memory tests using fair lineups, with no lineup administrator influence, and with an immediate confidence statement). Under those conditions, mock-crime studies and police department field studies have consistently shown that, for adults, (a) confidence and accuracy are strongly related and (b) high-confidence suspect identifications are remarkably accurate. However, when certain non-pristine testing conditions prevail (e.g., when unfair lineups are used), the accuracy of even a high-confidence suspect ID is seriously compromised. Unfortunately, some jurisdictions have not yet made reforms that would create pristine testing conditions and, hence, our conclusions about the reliability of high-confidence identifications cannot yet be applied to those jurisdictions. However, understanding the information value of eyewitness confidence under pristine testing conditions can help the criminal justice system to simultaneously achieve both of its main objectives: to exonerate the innocent (by better appreciating that initial, low-confidence suspect identifications are error prone) and to convict the guilty (by better appreciating that initial, high-confidence suspect identifications are surprisingly accurate under proper testing conditions).

  3. Prognostic significance of electrical alternans versus signal averaged electrocardiography in predicting the outcome of electrophysiological testing and arrhythmia-free survival

    NASA Technical Reports Server (NTRS)

    Armoundas, A. A.; Rosenbaum, D. S.; Ruskin, J. N.; Garan, H.; Cohen, R. J.

    1998-01-01

    OBJECTIVE: To investigate the accuracy of signal averaged electrocardiography (SAECG) and measurement of microvolt level T wave alternans as predictors of susceptibility to ventricular arrhythmias. DESIGN: Analysis of new data from a previously published prospective investigation. SETTING: Electrophysiology laboratory of a major referral hospital. PATIENTS AND INTERVENTIONS: 43 patients, not on class I or class III antiarrhythmic drug treatment, undergoing invasive electrophysiological testing had SAECG and T wave alternans measurements. The SAECG was considered positive in the presence of one (SAECG-I) or two (SAECG-II) of three standard criteria. T wave alternans was considered positive if the alternans ratio exceeded 3.0. MAIN OUTCOME MEASURES: Inducibility of sustained ventricular tachycardia or fibrillation during electrophysiological testing, and 20 month arrhythmia-free survival. RESULTS: The accuracy of T wave alternans in predicting the outcome of electrophysiological testing was 84% (p < 0.0001). Neither SAECG-I (accuracy 60%; p < 0.29) nor SAECG-II (accuracy 71%; p < 0.10) was a statistically significant predictor of electrophysiological testing. SAECG, T wave alternans, electrophysiological testing, and follow up data were available in 36 patients while not on class I or III antiarrhythmic agents. The accuracy of T wave alternans in predicting the outcome of arrhythmia-free survival was 86% (p < 0.030). Neither SAECG-I (accuracy 65%; p < 0.21) nor SAECG-II (accuracy 71%; p < 0.48) was a statistically significant predictor of arrhythmia-free survival. CONCLUSIONS: T wave alternans was a highly significant predictor of the outcome of electrophysiological testing and arrhythmia-free survival, while SAECG was not a statistically significant predictor. Although these results need to be confirmed in prospective clinical studies, they suggest that T wave alternans may serve as a non-invasive probe for screening high risk populations for malignant ventricular arrhythmias.

  4. Three-Dimensional Accuracy of Facial Scan for Facial Deformities in Clinics: A New Evaluation Method for Facial Scanner Accuracy.

    PubMed

    Zhao, Yi-Jiao; Xiong, Yu-Xue; Wang, Yong

    2017-01-01

    In this study, the practical accuracy (PA) of optical facial scanners for facial deformity patients in oral clinic was evaluated. Ten patients with a variety of facial deformities from oral clinical were included in the study. For each patient, a three-dimensional (3D) face model was acquired, via a high-accuracy industrial "line-laser" scanner (Faro), as the reference model and two test models were obtained, via a "stereophotography" (3dMD) and a "structured light" facial scanner (FaceScan) separately. Registration based on the iterative closest point (ICP) algorithm was executed to overlap the test models to reference models, and "3D error" as a new measurement indicator calculated by reverse engineering software (Geomagic Studio) was used to evaluate the 3D global and partial (upper, middle, and lower parts of face) PA of each facial scanner. The respective 3D accuracy of stereophotography and structured light facial scanners obtained for facial deformities was 0.58±0.11 mm and 0.57±0.07 mm. The 3D accuracy of different facial partitions was inconsistent; the middle face had the best performance. Although the PA of two facial scanners was lower than their nominal accuracy (NA), they all met the requirement for oral clinic use.

  5. Supervised segmentation of microelectrode recording artifacts using power spectral density.

    PubMed

    Bakstein, Eduard; Schneider, Jakub; Sieger, Tomas; Novak, Daniel; Wild, Jiri; Jech, Robert

    2015-08-01

    Appropriate detection of clean signal segments in extracellular microelectrode recordings (MER) is vital for maintaining high signal-to-noise ratio in MER studies. Existing alternatives to manual signal inspection are based on unsupervised change-point detection. We present a method of supervised MER artifact classification, based on power spectral density (PSD) and evaluate its performance on a database of 95 labelled MER signals. The proposed method yielded test-set accuracy of 90%, which was close to the accuracy of annotation (94%). The unsupervised methods achieved accuracy of about 77% on both training and testing data.

  6. Accuracy of a Laryngopharyngeal Endoscopic Esthesiometer (LPEER) for Evaluating Laryngopharyngeal Mechanosensitivity: A Validation Study in a Prospectively Recruited Cohort of Patients.

    PubMed

    Giraldo-Cadavid, Luis F; Burguete, Javier; Rueda, Felipe; Galvis, Ana M; Castaneda, Natalia; Arbulu, Mario; Balaguera, Jorge I; Paez, Nelson; Fernandez, Secundino

    2018-02-01

    Recent studies have shown an association between alterations in laryngopharyngeal mechanosensitivity (LPMS) and dysphagia, obstructive sleep apnea, and chronic cough hypersensitivity syndrome. A previous reliability study of a new laryngopharyngeal endoscopic esthesiometer and rangefinder (LPEER) showed high intra- and inter-rater reliability; however, its accuracy has not been tested. We performed an accuracy study of the LPEER in a prospectively and consecutively recruited cohort of 118 patients at two tertiary care university hospitals. Most of the patients were suffering from dysphagia, and all of them underwent a standard clinical evaluation and fiberoptic endoscopic evaluation of swallowing with sensory testing (FEESST) using a new sensory testing protocol. The sensory test included determinations of the laryngeal adductor reflex threshold (LART), the cough reflex threshold (CRT) and the gag reflex threshold (GRT). Abnormalities on these reflex thresholds were evaluated for associations with major alterations in swallowing safety (pharyngeal residues, penetration, and aspiration). We evaluated the discriminative capacity of the LPMS test using ROC curves and the area under the curve (AUC-ROC) and its relationship with the eight-point penetration-aspiration scale (PAS) using the Spearman's ρ correlation coefficient (SCC). We found a positive correlation between the PAS and LART (SCC 0.47; P < 0.001), CRT (SCC 0.46; P < 0.001) and GRT (SCC 0.34; P = 0.002). The AUC-ROC values for detecting a PAS ≥7 were as follows: LART, 0.83 (P < 0.0001); CRT, 0.79 (P < 0.0001); GRT, 0.72 (P < 0.0001). In this study, the LPEER showed good accuracy for evaluating LPMS. These results justify further validation studies in independent populations.

  7. Investigation of Metabolomic Blood Biomarkers for Detection of Adenocarcinoma Lung Cancer

    PubMed Central

    Fahrmann, Johannes F.; Kim, Kyoungmi; DeFelice, Brian C.; Taylor, Sandra L.; Gandara, David R.; Yoneda, Ken Y.; Cooke, David T.; Fiehn, Oliver; Kelly, Karen; Miyamoto, Suzanne

    2015-01-01

    Background Untargeted metabolomics was utilized in case control studies of adenocarcinoma (ADC) lung cancer in order to develop and test metabolite classifiers in serum and plasma as potential biomarkers for diagnosing lung cancer. Methods Serum and plasma were collected and used in two independent case-control studies (ADC1 and ADC2). Controls were frequency matched for gender, age and smoking history. There were 52 ADC cases and 31 controls in ADC1 and 43 ADC cases and 43 controls in ADC2. Metabolomics was conducted using gas chromatography time-of-flight mass spectrometry. Differential analysis was performed on ADC1 and the top candidates (FDR < 0.05) for serum and plasma used to develop individual and multiplex-classifiers that were then tested on an independent set of serum and plasma samples (ADC2). Results Aspartate provided the best accuracy (81.4%) for an individual metabolite classifier in serum whereas pyrophosphate had the best accuracy (77.9%) in plasma when independently tested. Multiplex classifiers of either 2 or 4 serum metabolites had an accuracy of 72.7% when independently tested. For plasma, a multi-metabolite classifier consisting of 8 metabolites gave an accuracy of 77.3% when independently tested. Comparison of overall diagnostic performance between the two blood matrices yielded similar performances. However, serum is most ideal given higher sensitivity for low abundant metabolites. Conclusion This study shows the potential of metabolite-based diagnostic tests for detection of lung adenocarcinoma. Further validation in a larger pool of samples is warranted. Impact These biomarkers could improve early detection and diagnosis of lung cancer. PMID:26282632

  8. The accuracy of postoperative, non-invasive Air-Test to diagnose atelectasis in healthy patients after surgery: a prospective, diagnostic pilot study

    PubMed Central

    Ferrando, Carlos; Romero, Carolina; Tusman, Gerardo; Suarez-Sipmann, Fernando; Canet, Jaume; Dosdá, Rosa; Valls, Paola; Villena, Abigail; Serralta, Ferran; Jurado, Ana; Carrizo, Juan; Navarro, Jose; Parrilla, Cristina; Romero, Jose E; Pozo, Natividad; Soro, Marina; Villar, Jesús; Belda, Francisco Javier

    2017-01-01

    Objective To assess the diagnostic accuracy of peripheral capillary oxygen saturation (SpO2) while breathing room air for 5 min (the ‘Air-Test’) in detecting postoperative atelectasis. Design Prospective cohort study. Diagnostic accuracy was assessed by measuring the agreement between the index test and the reference standard CT scan images. Setting Postanaesthetic care unit in a tertiary hospital in Spain. Participants Three hundred and fifty patients from 12 January to 7 February 2015; 170 patients scheduled for surgery under general anaesthesia who were admitted into the postsurgical unit were included. Intervention The Air-Test was performed in conscious extubated patients after a 30 min stabilisation period during which they received supplemental oxygen therapy via a venturi mask. The Air-Test was defined as positive when SpO2 was ≤96% and negative when SpO2 was ≥97%. Arterial blood gases were measured in all patients at the end of the Air-Test. In the subsequent 25 min, the presence of atelectasis was evaluated by performing a CT scan in 59 randomly selected patients. Main outcome measures The primary study outcome was assessment of the accuracy of the Air-Test for detecting postoperative atelectasis compared with the reference standard. The secondary outcome was the incidence of positive Air-Test results. Results The Air-Test diagnosed postoperative atelectasis with an area under the receiver operating characteristic curve of 0.90 (95% CI 0.82 to 0.98) with a sensitivity of 82.6% and a specificity of 87.8%. The presence of atelectasis was confirmed by CT scans in all patients (30/30) with positive and in 5 patients (17%) with negative Air-Test results. Based on the Air-Test, postoperative atelectasis was present in 36% of the patients (62 out of 170). Conclusion The Air-Test may represent an accurate, simple, inexpensive and non-invasive method for diagnosing postoperative atelectasis. Trial Registration NCT02650037. PMID:28554935

  9. Transfer Learning with Convolutional Neural Networks for Classification of Abdominal Ultrasound Images.

    PubMed

    Cheng, Phillip M; Malhi, Harshawn S

    2017-04-01

    The purpose of this study is to evaluate transfer learning with deep convolutional neural networks for the classification of abdominal ultrasound images. Grayscale images from 185 consecutive clinical abdominal ultrasound studies were categorized into 11 categories based on the text annotation specified by the technologist for the image. Cropped images were rescaled to 256 × 256 resolution and randomized, with 4094 images from 136 studies constituting the training set, and 1423 images from 49 studies constituting the test set. The fully connected layers of two convolutional neural networks based on CaffeNet and VGGNet, previously trained on the 2012 Large Scale Visual Recognition Challenge data set, were retrained on the training set. Weights in the convolutional layers of each network were frozen to serve as fixed feature extractors. Accuracy on the test set was evaluated for each network. A radiologist experienced in abdominal ultrasound also independently classified the images in the test set into the same 11 categories. The CaffeNet network classified 77.3% of the test set images accurately (1100/1423 images), with a top-2 accuracy of 90.4% (1287/1423 images). The larger VGGNet network classified 77.9% of the test set accurately (1109/1423 images), with a top-2 accuracy of VGGNet was 89.7% (1276/1423 images). The radiologist classified 71.7% of the test set images correctly (1020/1423 images). The differences in classification accuracies between both neural networks and the radiologist were statistically significant (p < 0.001). The results demonstrate that transfer learning with convolutional neural networks may be used to construct effective classifiers for abdominal ultrasound images.

  10. The Effect of Delayed-JOLs and Sentence Generation on Children's Monitoring Accuracy and Regulation of Idiom Study

    ERIC Educational Resources Information Center

    van Loon, Mariëtte H.; de Bruin, Anique B. H.; van Gog, Tamara; van Merriënboer, Jeroen J. G.

    2013-01-01

    When studying verbal materials, both adults and children are often poor at accurately monitoring their level of learning and regulating their subsequent restudy of materials, which leads to suboptimal test performance. The present experiment investigated how monitoring accuracy and regulation of study could be improved when learning idiomatic…

  11. Methods for the Joint Meta-Analysis of Multiple Tests

    ERIC Educational Resources Information Center

    Trikalinos, Thomas A.; Hoaglin, David C.; Small, Kevin M.; Terrin, Norma; Schmid, Christopher H.

    2014-01-01

    Existing methods for meta-analysis of diagnostic test accuracy focus primarily on a single index test. We propose models for the joint meta-analysis of studies comparing multiple index tests on the same participants in paired designs. These models respect the grouping of data by studies, account for the within-study correlation between the tests'…

  12. Added value of cost-utility analysis in simple diagnostic studies of accuracy: (18)F-fluoromethylcholine PET/CT in prostate cancer staging.

    PubMed

    Gerke, Oke; Poulsen, Mads H; Høilund-Carlsen, Poul Flemming

    2015-01-01

    Diagnostic studies of accuracy targeting sensitivity and specificity are commonly done in a paired design in which all modalities are applied in each patient, whereas cost-effectiveness and cost-utility analyses are usually assessed either directly alongside to or indirectly by means of stochastic modeling based on larger randomized controlled trials (RCTs). However the conduct of RCTs is hampered in an environment such as ours, in which technology is rapidly evolving. As such, there is a relatively limited number of RCTs. Therefore, we investigated as to which extent paired diagnostic studies of accuracy can be also used to shed light on economic implications when considering a new diagnostic test. We propose a simple decision tree model-based cost-utility analysis of a diagnostic test when compared to the current standard procedure and exemplify this approach with published data from lymph node staging of prostate cancer. Average procedure costs were taken from the Danish Diagnosis Related Groups Tariff in 2013 and life expectancy was estimated for an ideal 60 year old patient based on prostate cancer stage and prostatectomy or radiation and chemotherapy. Quality-adjusted life-years (QALYs) were deduced from the literature, and an incremental cost-effectiveness ratio (ICER) was used to compare lymph node dissection with respective histopathological examination (reference standard) and (18)F-fluoromethylcholine positron emission tomography/computed tomography (FCH-PET/CT). Lower bounds of sensitivity and specificity of FCH-PET/CT were established at which the replacement of the reference standard by FCH-PET/CT comes with a trade-off between worse effectiveness and lower costs. Compared to the reference standard in a diagnostic accuracy study, any imperfections in accuracy of a diagnostic test imply that replacing the reference standard generates a loss in effectiveness and utility. We conclude that diagnostic studies of accuracy can be put to a more extensive use, over and above a mere indication of sensitivity and specificity of an imaging test, and that health economic considerations should be undertaken when planning a prospective diagnostic accuracy study. These endeavors will prove especially fruitful when comparing several imaging techniques with one another, or the same imaging technique using different tracers, with an independent reference standard for the evaluation of results.

  13. Diagnostic accuracy of clinical tests for assessment of hamstring injury: a systematic review.

    PubMed

    Reiman, Michael P; Loudon, Janice K; Goode, Adam P

    2013-04-01

    Systematic literature review. The diagnosis of a hamstring injury has traditionally relied on various clinical measures (eg, palpation, swelling, manual resistance), as well as the use of diagnostic imaging. But a few studies have suggested the use of specific clinical tests that may be helpful for the diagnostic process. To summarize the current literature on the diagnostic accuracy of orthopaedic special tests for hamstring injuries and to determine their clinical utility. A computer-assisted literature search of the MEDLINE, CINAHL, and Embase databases (along with a manual search of grey literature) was conducted using key words related to diagnostic accuracy of hamstring injuries. To be considered for inclusion in the review, the study required (1) patients with hamstring or posterior thigh pain; (2) a cohort, case-control, or cross-sectional design; (3) inclusion of at least 1 clinical examination test used to evaluate hamstring pathology; (4) comparison against an acceptable reference standard; (5) reporting of diagnostic accuracy of the measures (sensitivity [SN], specificity [SP], or likelihood ratios); and (6) publication in English. SN, SP, and positive and negative likelihood ratios were calculated for each diagnostic test. The search strategy identified 602 potential articles, of which only 3 articles met the inclusion criteria, with only 1 of these 3 articles being of high quality. Two of the studies investigated a single special test, whereas the third article examined a composite clinical assessment employing various special tests. The SN values ranged from 0.55 (95% confidence interval [CI]: 0.46, 0.69) for the active range-of-motion test to 1.00 (95% CI: 0.97, 1.00) for the taking-off-the-shoe test. The SP values ranged from 0.03 (95% CI: 0.00, 0.22) for the composite clinical assessment to 1.00 (95% CI: 0.97, 1.00) for the taking-off-the-shoe test, active range-of-motion test, passive range-of-motion test, and resisted range-of-motion test. The use of a single special test demonstrated stronger SP than SN properties, whereas the composite clinical assessment demonstrated stronger SN than SP properties. Very few studies have investigated the utilization of clinical special tests for the diagnosis of hamstring injuries. Further studies of higher quality design are suggested prior to advocating independent clinical utilization of these special tests. Diagnosis, level 3b.

  14. VOLUMETRIC TANK TESTING: AN OVERVIEW

    EPA Science Inventory

    This report summarizes the technical findings of an EPA study on volumetric tank testing. The results of this study, which evaluated the viability of volumetric tank tests as a means of detecting leaks in underground storage tanks, are described. Also, the accuracy requirements s...

  15. Meta-analysis of diagnostic accuracy studies accounting for disease prevalence: alternative parameterizations and model selection.

    PubMed

    Chu, Haitao; Nie, Lei; Cole, Stephen R; Poole, Charles

    2009-08-15

    In a meta-analysis of diagnostic accuracy studies, the sensitivities and specificities of a diagnostic test may depend on the disease prevalence since the severity and definition of disease may differ from study to study due to the design and the population considered. In this paper, we extend the bivariate nonlinear random effects model on sensitivities and specificities to jointly model the disease prevalence, sensitivities and specificities using trivariate nonlinear random-effects models. Furthermore, as an alternative parameterization, we also propose jointly modeling the test prevalence and the predictive values, which reflect the clinical utility of a diagnostic test. These models allow investigators to study the complex relationship among the disease prevalence, sensitivities and specificities; or among test prevalence and the predictive values, which can reveal hidden information about test performance. We illustrate the proposed two approaches by reanalyzing the data from a meta-analysis of radiological evaluation of lymph node metastases in patients with cervical cancer and a simulation study. The latter illustrates the importance of carefully choosing an appropriate normality assumption for the disease prevalence, sensitivities and specificities, or the test prevalence and the predictive values. In practice, it is recommended to use model selection techniques to identify a best-fitting model for making statistical inference. In summary, the proposed trivariate random effects models are novel and can be very useful in practice for meta-analysis of diagnostic accuracy studies. Copyright 2009 John Wiley & Sons, Ltd.

  16. Can extra-articular strains be used to measure facet contact forces in the lumbar spine? An in-vitro biomechanical study.

    PubMed

    Zhu, Q A; Park, Y B; Sjovold, S G; Niosi, C A; Wilson, D C; Cripton, P A; Oxland, T R

    2008-02-01

    Experimental measurement of the load-bearing patterns of the facet joints in the lumbar spine remains a challenge, thereby limiting the assessment of facet joint function under various surgical conditions and the validation of computational models. The extra-articular strain (EAS) technique, a non-invasive measurement of the contact load, has been used for unilateral facet joints but does not incorporate strain coupling, i.e. ipsilateral EASs due to forces on the contralateral facet joint. The objectives of the present study were to establish a bilateral model for facet contact force measurement using the EAS technique and to determine its effectiveness in measuring these facet joint contact forces during three-dimensional flexibility tests in the lumbar spine. Specific goals were to assess the accuracy and repeatability of the technique and to assess the effect of soft-tissue artefacts. In the accuracy and repeatability tests, ten uniaxial strain gauges were bonded to the external surface of the inferior facets of L3 of ten fresh lumbar spine specimens. Two pressure-sensitive sensors (Tekscan) were inserted into the joints after the capsules were cut. Facet contact forces were measured with the EAS and Tekscan techniques for each specimen in flexion, extension, axial rotation, and lateral bending under a +/- 7.5 N m pure moment. Four of the ten specimens were tested five times in axial rotation and extension for repeatability. These same specimens were disarticulated and known forces were applied across the facet joint using a manual probe (direct accuracy) and a materials-testing system (disarticulated accuracy). In soft-tissue artefact tests, a separate set of six lumbar spine specimens was used to document the virtual facet joint contact forces during a flexibility test following removal of the superior facet processes. Linear strain coupling was observed in all specimens. The average peak facet joint contact forces during flexibility testing was greatest in axial rotation (71 +/- 25 N), followed by extension (27 +/- 35 N) and lateral bending (25 +/- 28 N), and they were most repeatable in axial rotation (coefficient of variation, 5 per cent). The EAS accuracy was about 20 per cent in the direct accuracy assessment and about 30 per cent in the disarticulated accuracy test. The latter was very similar to the Tekscan accuracy in the same test. Virtual facet loads (r.m.s.) were small in axial rotation (12 N) and lateral bending (20 N), but relatively large in flexion (34 N) and extension (35 N). The results suggested that the bilateral EAS model could be used to determine the facet joint contact forces in axial rotation but may result in considerable error in flexion, extension, and lateral bending.

  17. Early-Onset Neonatal Sepsis: Still Room for Improvement in Procalcitonin Diagnostic Accuracy Studies

    PubMed Central

    Chiesa, Claudio; Pacifico, Lucia; Osborn, John F.; Bonci, Enea; Hofer, Nora; Resch, Bernhard

    2015-01-01

    Abstract To perform a systematic review assessing accuracy and completeness of diagnostic studies of procalcitonin (PCT) for early-onset neonatal sepsis (EONS) using the Standards for Reporting of Diagnostic Accuracy (STARD) initiative. EONS, diagnosed during the first 3 days of life, remains a common and serious problem. Increased PCT is a potentially useful diagnostic marker of EONS, but reports in the literature are contradictory. There are several possible explanations for the divergent results including the quality of studies reporting the clinical usefulness of PCT in ruling in or ruling out EONS. We systematically reviewed PubMed, Scopus, and the Cochrane Library databases up to October 1, 2014. Studies were eligible for inclusion in our review if they provided measures of PCT accuracy for diagnosing EONS. A data extraction form based on the STARD checklist and adapted for neonates with EONS was used to appraise the quality of the reporting of included studies. We found 18 articles (1998–2014) fulfilling our eligibility criteria which were included in the final analysis. Overall, the results of our analysis showed that the quality of studies reporting diagnostic accuracy of PCT for EONS was suboptimal leaving ample room for improvement. Information on key elements of design, analysis, and interpretation of test accuracy were frequently missing. Authors should be aware of the STARD criteria before starting a study in this field. We welcome stricter adherence to this guideline. Well-reported studies with appropriate designs will provide more reliable information to guide decisions on the use and interpretations of PCT test results in the management of neonates with EONS. PMID:26222858

  18. Central additive effect of Ginkgo biloba and Rhodiola rosea on psychomotor vigilance task and short-term working memory accuracy.

    PubMed

    Al-Kuraishy, Hayder M

    2016-01-01

    The present study investigates the effect of combined treatment with Ginkgo biloba and/or Rhodiola rosea on psychomotor vigilance task (PVT) and short-term working memory accuracy. A total number of 112 volunteers were enrolled to study the effect of G. biloba and R. rosea on PVT and short-term working memory accuracy as compared to placebo effects, the central cognitive effect was assessed by critical flicker-fusion frequency, PVT, and computerized N-back test. Placebo produced no significant effects on all neurocognitive tests measure P > 0.05 in normal healthy volunteers, G. biloba or R. rosea improve PVT and low to moderate working memory accuracy, The combined effect of R. rosea and G. biloba leading to more significant effect on PVT, all levels of short-term working memory accuracy and critical fusion versus flicker P < 0.01, more than of G. biloba or R. rosea when they used alone. The combined effect of R. rosea and G. biloba leading to a more significant effect on cognitive function than either G. biloba or R. rosea when they used alone.

  19. The control of manual entry accuracy in management/engineering information systems, phase 1

    NASA Technical Reports Server (NTRS)

    Hays, Daniel; Nocke, Henry; Wilson, Harold; Woo, John, Jr.; Woo, June

    1987-01-01

    It was shown that clerical personnel can be tested for proofreading performance under simulated industrial conditions. A statistical study showed that errors in proofreading follow an extreme value probability theory. The study showed that innovative man/machine interfaces can be developed to improve and control accuracy during data entry.

  20. Diagnostic Accuracy of Chinese Medicine Diagnosis Scale of Phlegm and Blood Stasis Syndrome in Coronary Heart Disease: A Study Protocol.

    PubMed

    Liu, Xiao-Qi; Peng, Dan-Hong; Wang, Yan-Ping; Xie, Rong; Chen, Xin-Lin; Yu, Chun-Quan; Li, Xian-Tao

    2018-05-03

    Phlegm and blood stasis syndrome (PBSS) is one of the main syndromes in coronary heart disease (CHD). Syndromes of Chinese medicine (CM) are lack of quantitative and easyimplementation diagnosis standards. To quantify and standardize the diagnosis of PBSS, scales are usually applied. To evaluate the diagnostic accuracy of CM diagnosis scale of PBSS in CHD. Six hundred patients with stable angina pectoris of CHD, 300 in case group and 300 in control group, will be recruited from 5 hospitals across China. Diagnosis from 2 experts will be considered as the "gold standard". The study design consists of 2 phases: pilot test is used to evaluate the reliability and validity, and diagnostic test is used to assess the diagnostic accuracy of the scale, including sensitivity, specififi city, likelihood ratio and area under the receiver operator characteristic (ROC) curve. This study will evaluate the diagnostic accuracy of CM diagnosis scale of PBSS in CHD. The consensus of 2 experts may not be ideal as a "gold standard", and itself still requires further study. (No. ChiCTR-OOC-15006599).

  1. Comparative analysis of Mouse Inoculation Test and Virus Isolation in Cell Culture for rabies diagnosis in animals of Parana, Brazil.

    PubMed

    Corona, Thaila Francini; Böger, Beatriz; Rocha, Tatiana Carneiro da; Svoboda, Walfrido Külh; Gomes, Eliane Carneiro

    2018-01-01

    Rabies is an acute zoonotic disease, caused by a rhabdovirus that can affect all mammals, and is commonly transmitted by the bite of a rabid animal. The definitive diagnosis is laboratorial, by the Fluorescent Antibody Test (FAT) as a quick test and Mouse Inoculation Test (MIT) as a confirmatory test (gold standard). Studies conducted over the past three decades indicate that MIT and Virus Isolation in Cell Culture (VICC) can provide the same effectiveness, the latter being considered superior in bioethics and animal welfare. The aim of this study was to compare VICC with MIT, in terms of accuracy, biosafety and occupational health, supply and equipment costs, bioethics and animal welfare, in a Brazilian public health lab. We utilized 400 samples of animal neurological tissue to compare the performance of VICC against MIT. The variables analyzed were accuracy, biosafety and occupational health, time spent in performing the tests, supply and equipment costs, bioethics and animal welfare evaluation. Both VICC and MIT had almost the same accuracy (99.8%), although VICC presented fewer risks regarding biosafety and mental health of the technicians, and reduced time between inoculation and obtaining the results (approximately 22 days less). In addition, VICC presented lower supply costs (86.5% less), equipment costs (32.6% less), and the advantage of not using animals. These results confirm that VICC can replace MIT, offering the same accuracy and better features regarding cost, results, biosafety and occupational health, and bioethics and animal welfare.

  2. Confirmatory Tests for the Diagnosis of Primary Aldosteronism: A Prospective Diagnostic Accuracy Study.

    PubMed

    Song, Ying; Yang, Shumin; He, Wenwen; Hu, Jinbo; Cheng, Qingfeng; Wang, Yue; Luo, Ting; Ma, Linqiang; Zhen, Qianna; Zhang, Suhua; Mei, Mei; Wang, Zhihong; Qing, Hua; Bruemmer, Dennis; Peng, Bin; Li, Qifu

    2018-01-01

    The diagnosis of primary aldosteronism typically requires at least one confirmatory test. The fludrocortisone suppression test is generally accepted as a reliable confirmatory test, but it is cumbersome. Evidence from accuracy studies of the saline infusion test (SIT) and the captopril challenge test (CCT) has provided conflicting results. This prospective study aimed to evaluate the diagnostic accuracy of the SIT and CCT using fludrocortisone suppression test as the reference standard. One hundred thirty-five patients diagnosed with primary aldosteronism and 101 patients diagnosed with essential hypertension who completed the 3 confirmatory tests were included for the diagnostic accuracy analysis. The areas under the receiver-operator characteristics curves of the CCT and SIT were 0.96 (95% confidence interval [CI], 0.92-0.98) and 0.96 (95% CI, 0.92-0.98), respectively, using post-test plasma aldosterone concentration (PAC) for diagnosis. However, the areas under the receiver-operator characteristics curves of the CCT decreased to 0.71 (95% CI, 0.65-0.77) when the PAC suppression percentage was used to diagnose primary aldosteronism. The optimal cutoff of PAC post-CCT was set at 11 ng/dL, resulting in a sensitivity of 0.90 (95% CI, 0.84-0.95) and a specificity of 0.90 (95% CI, 0.83-0.95), which were not significantly different from those of SIT (with PAC post-SIT set at 8 ng/dL, sensitivity: 0.85 [95% CI, 0.78-0.91], P =0.192; specificity: 0.92 [95% CI, 0.85-0.97], P =0.551). In conclusion, both CCT and SIT are accurate alternatives to the more complex fludrocortisone suppression test. Because CCT is safe and much easier to perform, it may serve as a more feasible alternative. When interpreting the results of CCT, PAC post-CCT is highly recommended. © 2017 American Heart Association, Inc.

  3. Refining Ovarian Cancer Test accuracy Scores (ROCkeTS): protocol for a prospective longitudinal test accuracy study to validate new risk scores in women with symptoms of suspected ovarian cancer

    PubMed Central

    Sundar, Sudha; Rick, Caroline; Dowling, Francis; Au, Pui; Rai, Nirmala; Champaneria, Rita; Stobart, Hilary; Neal, Richard; Davenport, Clare; Mallett, Susan; Sutton, Andrew; Kehoe, Sean; Timmerman, Dirk; Bourne, Tom; Van Calster, Ben; Gentry-Maharaj, Aleksandra; Deeks, Jon

    2016-01-01

    Introduction Ovarian cancer (OC) is associated with non-specific symptoms such as bloating, making accurate diagnosis challenging: only 1 in 3 women with OC presents through primary care referral. National Institute for Health and Care Excellence guidelines recommends sequential testing with CA125 and routine ultrasound in primary care. However, these diagnostic tests have limited sensitivity or specificity. Improving accurate triage in women with vague symptoms is likely to improve mortality by streamlining referral and care pathways. The Refining Ovarian Cancer Test Accuracy Scores (ROCkeTS; HTA 13/13/01) project will derive and validate new tests/risk prediction models that estimate the probability of having OC in women with symptoms. This protocol refers to the prospective study only (phase III). Methods and analysis ROCkeTS comprises four parallel phases. The full ROCkeTS protocol can be found at http://www.birmingham.ac.uk/ROCKETS. Phase III is a prospective test accuracy study. The study will recruit 2450 patients from 15 UK sites. Recruited patients complete symptom and anxiety questionnaires, donate a serum sample and undergo ultrasound scored as per International Ovarian Tumour Analysis (IOTA) criteria. Recruitment is at rapid access clinics, emergency departments and elective clinics. Models to be evaluated include those based on ultrasound derived by the IOTA group and novel models derived from analysis of existing data sets. Estimates of sensitivity, specificity, c-statistic (area under receiver operating curve), positive predictive value and negative predictive value of diagnostic tests are evaluated and a calibration plot for models will be presented. ROCkeTS has received ethical approval from the NHS West Midlands REC (14/WM/1241) and is registered on the controlled trials website (ISRCTN17160843) and the National Institute of Health Research Cancer and Reproductive Health portfolios. PMID:27507231

  4. Presymptomatic electrophysiological tests predict clinical onset and survival in SOD1(G93A) ALS mice.

    PubMed

    Mancuso, Renzo; Osta, Rosario; Navarro, Xavier

    2014-12-01

    We assessed the predictive value of electrophysiological tests as a marker of clinical disease onset and survival in superoxide-dismutase 1 (SOD1)(G93A) mice. We evaluated the accuracy of electrophysiological tests in differentiating transgenic versus wild-type mice. We made a correlation analysis of electrophysiological parameters and the onset of symptoms, survival, and number of spinal motoneurons. Presymptomatic electrophysiological tests show great accuracy in differentiating transgenic versus wild-type mice, with the most sensitive parameter being the tibialis anterior compound muscle action potential (CMAP) amplitude. The CMAP amplitude at age 10 weeks correlated significantly with clinical disease onset and survival. Electrophysiological tests increased their survival prediction accuracy when evaluated at later stages of the disease and also predicted the amount of lumbar spinal motoneuron preservation. Electrophysiological tests predict clinical disease onset, survival, and spinal motoneuron preservation in SOD1(G93A) mice. This is a methodological improvement for preclinical studies. © 2014 Wiley Periodicals, Inc.

  5. Comparison of accuracy of fibrosis degree classifications by liver biopsy and non-invasive tests in chronic hepatitis C.

    PubMed

    Boursier, Jérôme; Bertrais, Sandrine; Oberti, Frédéric; Gallois, Yves; Fouchard-Hubert, Isabelle; Rousselet, Marie-Christine; Zarski, Jean-Pierre; Calès, Paul

    2011-11-30

    Non-invasive tests have been constructed and evaluated mainly for binary diagnoses such as significant fibrosis. Recently, detailed fibrosis classifications for several non-invasive tests have been developed, but their accuracy has not been thoroughly evaluated in comparison to liver biopsy, especially in clinical practice and for Fibroscan. Therefore, the main aim of the present study was to evaluate the accuracy of detailed fibrosis classifications available for non-invasive tests and liver biopsy. The secondary aim was to validate these accuracies in independent populations. Four HCV populations provided 2,068 patients with liver biopsy, four different pathologist skill-levels and non-invasive tests. Results were expressed as percentages of correctly classified patients. In population #1 including 205 patients and comparing liver biopsy (reference: consensus reading by two experts) and blood tests, Metavir fibrosis (FM) stage accuracy was 64.4% in local pathologists vs. 82.2% (p < 10-3) in single expert pathologist. Significant discrepancy (≥ 2FM vs reference histological result) rates were: Fibrotest: 17.2%, FibroMeter2G: 5.6%, local pathologists: 4.9%, FibroMeter3G: 0.5%, expert pathologist: 0% (p < 10-3). In population #2 including 1,056 patients and comparing blood tests, the discrepancy scores, taking into account the error magnitude, of detailed fibrosis classification were significantly different between FibroMeter2G (0.30 ± 0.55) and FibroMeter3G (0.14 ± 0.37, p < 10-3) or Fibrotest (0.84 ± 0.80, p < 10-3). In population #3 (and #4) including 458 (359) patients and comparing blood tests and Fibroscan, accuracies of detailed fibrosis classification were, respectively: Fibrotest: 42.5% (33.5%), Fibroscan: 64.9% (50.7%), FibroMeter2G: 68.7% (68.2%), FibroMeter3G: 77.1% (83.4%), p < 10-3 (p < 10-3). Significant discrepancy (≥ 2 FM) rates were, respectively: Fibrotest: 21.3% (22.2%), Fibroscan: 12.9% (12.3%), FibroMeter2G: 5.7% (6.0%), FibroMeter3G: 0.9% (0.9%), p < 10-3 (p < 10-3). The accuracy in detailed fibrosis classification of the best-performing blood test outperforms liver biopsy read by a local pathologist, i.e., in clinical practice; however, the classification precision is apparently lesser. This detailed classification accuracy is much lower than that of significant fibrosis with Fibroscan and even Fibrotest but higher with FibroMeter3G. FibroMeter classification accuracy was significantly higher than those of other non-invasive tests. Finally, for hepatitis C evaluation in clinical practice, fibrosis degree can be evaluated using an accurate blood test.

  6. Comparison of accuracy of fibrosis degree classifications by liver biopsy and non-invasive tests in chronic hepatitis C

    PubMed Central

    2011-01-01

    Background Non-invasive tests have been constructed and evaluated mainly for binary diagnoses such as significant fibrosis. Recently, detailed fibrosis classifications for several non-invasive tests have been developed, but their accuracy has not been thoroughly evaluated in comparison to liver biopsy, especially in clinical practice and for Fibroscan. Therefore, the main aim of the present study was to evaluate the accuracy of detailed fibrosis classifications available for non-invasive tests and liver biopsy. The secondary aim was to validate these accuracies in independent populations. Methods Four HCV populations provided 2,068 patients with liver biopsy, four different pathologist skill-levels and non-invasive tests. Results were expressed as percentages of correctly classified patients. Results In population #1 including 205 patients and comparing liver biopsy (reference: consensus reading by two experts) and blood tests, Metavir fibrosis (FM) stage accuracy was 64.4% in local pathologists vs. 82.2% (p < 10-3) in single expert pathologist. Significant discrepancy (≥ 2FM vs reference histological result) rates were: Fibrotest: 17.2%, FibroMeter2G: 5.6%, local pathologists: 4.9%, FibroMeter3G: 0.5%, expert pathologist: 0% (p < 10-3). In population #2 including 1,056 patients and comparing blood tests, the discrepancy scores, taking into account the error magnitude, of detailed fibrosis classification were significantly different between FibroMeter2G (0.30 ± 0.55) and FibroMeter3G (0.14 ± 0.37, p < 10-3) or Fibrotest (0.84 ± 0.80, p < 10-3). In population #3 (and #4) including 458 (359) patients and comparing blood tests and Fibroscan, accuracies of detailed fibrosis classification were, respectively: Fibrotest: 42.5% (33.5%), Fibroscan: 64.9% (50.7%), FibroMeter2G: 68.7% (68.2%), FibroMeter3G: 77.1% (83.4%), p < 10-3 (p < 10-3). Significant discrepancy (≥ 2 FM) rates were, respectively: Fibrotest: 21.3% (22.2%), Fibroscan: 12.9% (12.3%), FibroMeter2G: 5.7% (6.0%), FibroMeter3G: 0.9% (0.9%), p < 10-3 (p < 10-3). Conclusions The accuracy in detailed fibrosis classification of the best-performing blood test outperforms liver biopsy read by a local pathologist, i.e., in clinical practice; however, the classification precision is apparently lesser. This detailed classification accuracy is much lower than that of significant fibrosis with Fibroscan and even Fibrotest but higher with FibroMeter3G. FibroMeter classification accuracy was significantly higher than those of other non-invasive tests. Finally, for hepatitis C evaluation in clinical practice, fibrosis degree can be evaluated using an accurate blood test. PMID:22129438

  7. Brain Painting: First Evaluation of a New Brain–Computer Interface Application with ALS-Patients and Healthy Volunteers

    PubMed Central

    Münßinger, Jana I.; Halder, Sebastian; Kleih, Sonja C.; Furdea, Adrian; Raco, Valerio; Hösle, Adi; Kübler, Andrea

    2010-01-01

    Brain–computer interfaces (BCIs) enable paralyzed patients to communicate; however, up to date, no creative expression was possible. The current study investigated the accuracy and user-friendliness of P300-Brain Painting, a new BCI application developed to paint pictures using brain activity only. Two different versions of the P300-Brain Painting application were tested: A colored matrix tested by a group of ALS-patients (n = 3) and healthy participants (n = 10), and a black and white matrix tested by healthy participants (n = 10). The three ALS-patients achieved high accuracies; two of them reaching above 89% accuracy. In healthy subjects, a comparison between the P300-Brain Painting application (colored matrix) and the P300-Spelling application revealed significantly lower accuracy and P300 amplitudes for the P300-Brain Painting application. This drop in accuracy and P300 amplitudes was not found when comparing the P300-Spelling application to an adapted, black and white matrix of the P300-Brain Painting application. By employing a black and white matrix, the accuracy of the P300-Brain Painting application was significantly enhanced and reached the accuracy of the P300-Spelling application. ALS-patients greatly enjoyed P300-Brain Painting and were able to use the application with the same accuracy as healthy subjects. P300-Brain Painting enables paralyzed patients to express themselves creatively and to participate in the prolific society through exhibitions. PMID:21151375

  8. Exploratory study of the relations between spatial ability and drawing from memory.

    PubMed

    Czarnolewski, Mark Y; Eliot, John

    2012-04-01

    Test scores of 119 students, attending either a public four-year college or a technical school, were related to their proportionality and detail drawing scores on the Memory for Designs Test. In regression models, the ETS Maze Tracing, Eliot-Price Mental Rotations, and Bender-Gestalt tests were consistent predictors of proportionality scores, with the latter two tests uniquely related to these. The ETS Shapes Memory Test and the Form Board Test were the strongest predictors for detail accuracy scores. The Shapes test predicted proportionality when the CTY Visual Memory Test BB was excluded. The models then provided support for the hypothesis that drawing designs from memory, a critical skill in drawing, regardless of whether one focuses on accuracy for proportionality scores or for detail scores, is jointly related to the measures of recognition, production, and traditional spatial ability measures. This study identified multifaceted skills in drawing from memory.

  9. The neglected tool in the Bayesian ecologist's shed: a case study testing informative priors' effect on model accuracy

    PubMed Central

    Morris, William K; Vesk, Peter A; McCarthy, Michael A; Bunyavejchewin, Sarayudh; Baker, Patrick J

    2015-01-01

    Despite benefits for precision, ecologists rarely use informative priors. One reason that ecologists may prefer vague priors is the perception that informative priors reduce accuracy. To date, no ecological study has empirically evaluated data-derived informative priors' effects on precision and accuracy. To determine the impacts of priors, we evaluated mortality models for tree species using data from a forest dynamics plot in Thailand. Half the models used vague priors, and the remaining half had informative priors. We found precision was greater when using informative priors, but effects on accuracy were more variable. In some cases, prior information improved accuracy, while in others, it was reduced. On average, models with informative priors were no more or less accurate than models without. Our analyses provide a detailed case study on the simultaneous effect of prior information on precision and accuracy and demonstrate that when priors are specified appropriately, they lead to greater precision without systematically reducing model accuracy. PMID:25628867

  10. The neglected tool in the Bayesian ecologist's shed: a case study testing informative priors' effect on model accuracy.

    PubMed

    Morris, William K; Vesk, Peter A; McCarthy, Michael A; Bunyavejchewin, Sarayudh; Baker, Patrick J

    2015-01-01

    Despite benefits for precision, ecologists rarely use informative priors. One reason that ecologists may prefer vague priors is the perception that informative priors reduce accuracy. To date, no ecological study has empirically evaluated data-derived informative priors' effects on precision and accuracy. To determine the impacts of priors, we evaluated mortality models for tree species using data from a forest dynamics plot in Thailand. Half the models used vague priors, and the remaining half had informative priors. We found precision was greater when using informative priors, but effects on accuracy were more variable. In some cases, prior information improved accuracy, while in others, it was reduced. On average, models with informative priors were no more or less accurate than models without. Our analyses provide a detailed case study on the simultaneous effect of prior information on precision and accuracy and demonstrate that when priors are specified appropriately, they lead to greater precision without systematically reducing model accuracy.

  11. Improving coding accuracy in an academic practice.

    PubMed

    Nguyen, Dana; O'Mara, Heather; Powell, Robert

    2017-01-01

    Practice management has become an increasingly important component of graduate medical education. This applies to every practice environment; private, academic, and military. One of the most critical aspects of practice management is documentation and coding for physician services, as they directly affect the financial success of any practice. Our quality improvement project aimed to implement a new and innovative method for teaching billing and coding in a longitudinal fashion in a family medicine residency. We hypothesized that implementation of a new teaching strategy would increase coding accuracy rates among residents and faculty. Design: single group, pretest-posttest. military family medicine residency clinic. Study populations: 7 faculty physicians and 18 resident physicians participated as learners in the project. Educational intervention: monthly structured coding learning sessions in the academic curriculum that involved learner-presented cases, small group case review, and large group discussion. overall coding accuracy (compliance) percentage and coding accuracy per year group for the subjects that were able to participate longitudinally. Statistical tests used: average coding accuracy for population; paired t test to assess improvement between 2 intervention periods, both aggregate and by year group. Overall coding accuracy rates remained stable over the course of time regardless of the modality of the educational intervention. A paired t test was conducted to compare coding accuracy rates at baseline (mean (M)=26.4%, SD=10%) to accuracy rates after all educational interventions were complete (M=26.8%, SD=12%); t24=-0.127, P=.90. Didactic teaching and small group discussion sessions did not improve overall coding accuracy in a residency practice. Future interventions could focus on educating providers at the individual level.

  12. Correlation between Histological Status of the Pulp and Its Response to Sensibility Tests

    PubMed Central

    Naseri, Mandana; Khayat, Akbar; Zamaheni, Sara; Shojaeian, Shiva

    2017-01-01

    Introduction: The purpose of this study was to assess the accuracy of sensibility tests by correlating it with histologic pulp condition. Methods and Materials: Assessment of clinical signs and symptoms were performed on 65 permanent teeth that were scheduled to be extracted for periodontal, prosthodontic or orthodontic reasons. The normal pulp and reversible pulpitis were considered as treatable tooth conditions while irreversible pulpitis and necrosis were considered as untreatable conditions. The teeth were then extracted and sectioned for histological analysis of dental pulp. Histologic status and classification corresponded to the treatable or untreatable pulp condition. Comparisons between histological treatable and untreatable pulp condition were performed with chi-square analysis for sensibility test responses. The positive predictive value (PPV), negative predictive value (NPV) and accuracy to detect untreatable from treatable pulp condition were calculated for each test. Results: A significant difference was detected in the normal and a sharp lingered response to heat and cold tests. There was significant difference in the negative response to EPT between histological groups. The kappa agreement coefficient between clinical and histological diagnosis of pulp condition was about 0.843 (P<0.001). The accuracy of cold and heat tests and EPT to detect treatable pulp or untreatable pulp states were 78, 74 and 62%, respectively. The sensibility tests diagnosed untreatable pulpitis with a higher probability (NPV=63%-67% -54%, PPV=83%-91% -95% for heat, cold and EPT, respectively). Conclusion: Sensibility test results were more likely to diagnose pulpal disease or untreatable pulp conditions. However, to increase the diagnostic accuracy patient history, clinical signs and symptoms and also radiographic findings in conjunction with sensibility tests must be used. The result of this small study demonstrated a good agreement between clinical and histological pulp diagnosis. PMID:28179918

  13. Accuracy of p53 Codon 72 Polymorphism Status Determined by Multiple Laboratory Methods: A Latent Class Model Analysis

    PubMed Central

    Walter, Stephen D.; Riddell, Corinne A.; Rabachini, Tatiana; Villa, Luisa L.; Franco, Eduardo L.

    2013-01-01

    Introduction Studies on the association of a polymorphism in codon 72 of the p53 tumour suppressor gene (rs1042522) with cervical neoplasia have inconsistent results. While several methods for genotyping p53 exist, they vary in accuracy and are often discrepant. Methods We used latent class models (LCM) to examine the accuracy of six methods for p53 determination, all conducted by the same laboratory. We also examined the association of p53 with cytological cervical abnormalities, recognising potential test inaccuracy. Results Pairwise disagreement between laboratory methods occurred approximately 10% of the time. Given the estimated true p53 status of each woman, we found that each laboratory method is most likely to classify a woman to her correct status. Arg/Arg women had the highest risk of squamous intraepithelial lesions (SIL). Test accuracy was independent of cytology. There was no strong evidence for correlations of test errors. Discussion Empirical analyses ignore possible laboratory errors, and so are inherently biased, but test accuracy estimated by the LCM approach is unbiased when model assumptions are met. LCM analysis avoids ambiguities arising from empirical test discrepancies, obviating the need to regard any of the methods as a “gold” standard measurement. The methods we presented here to analyse the p53 data can be applied in many other situations where multiple tests exist, but where none of them is a gold standard. PMID:23441193

  14. Diagnostic accuracy of refractometer and Brix refractometer to assess failure of passive transfer in calves: protocol for a systematic review and meta-analysis.

    PubMed

    Buczinski, S; Fecteau, G; Chigerwe, M; Vandeweerd, J M

    2016-06-01

    Calves are highly dependent of colostrum (and antibody) intake because they are born agammaglobulinemic. The transfer of passive immunity in calves can be assessed directly by dosing immunoglobulin G (IgG) or by refractometry or Brix refractometry. The latter are easier to perform routinely in the field. This paper presents a protocol for a systematic review meta-analysis to assess the diagnostic accuracy of refractometry or Brix refractometry versus dosage of IgG as a reference standard test. With this review protocol we aim to be able to report refractometer and Brix refractometer accuracy in terms of sensitivity and specificity as well as to quantify the impact of any study characteristic on test accuracy.

  15. Systematic reviews of diagnostic tests in endocrinology: an audit of methods, reporting, and performance.

    PubMed

    Spencer-Bonilla, Gabriela; Singh Ospina, Naykky; Rodriguez-Gutierrez, Rene; Brito, Juan P; Iñiguez-Ariza, Nicole; Tamhane, Shrikant; Erwin, Patricia J; Murad, M Hassan; Montori, Victor M

    2017-07-01

    Systematic reviews provide clinicians and policymakers estimates of diagnostic test accuracy and their usefulness in clinical practice. We identified all available systematic reviews of diagnosis in endocrinology, summarized the diagnostic accuracy of the tests included, and assessed the credibility and clinical usefulness of the methods and reporting. We searched Ovid MEDLINE, EMBASE, and Cochrane CENTRAL from inception to December 2015 for systematic reviews and meta-analyses reporting accuracy measures of diagnostic tests in endocrinology. Experienced reviewers independently screened for eligible studies and collected data. We summarized the results, methods, and reporting of the reviews. We performed subgroup analyses to categorize diagnostic tests as most useful based on their accuracy. We identified 84 systematic reviews; half of the tests included were classified as helpful when positive, one-fourth as helpful when negative. Most authors adequately reported how studies were identified and selected and how their trustworthiness (risk of bias) was judged. Only one in three reviews, however, reported an overall judgment about trustworthiness and one in five reported using adequate meta-analytic methods. One in four reported contacting authors for further information and about half included only patients with diagnostic uncertainty. Up to half of the diagnostic endocrine tests in which the likelihood ratio was calculated or provided are likely to be helpful in practice when positive as are one-quarter when negative. Most diagnostic systematic reviews in endocrine lack methodological rigor, protection against bias, and offer limited credibility. Substantial efforts, therefore, seem necessary to improve the quality of diagnostic systematic reviews in endocrinology.

  16. Comparison of two data mining techniques in labeling diagnosis to Iranian pharmacy claim dataset: artificial neural network (ANN) versus decision tree model.

    PubMed

    Rezaei-Darzi, Ehsan; Farzadfar, Farshad; Hashemi-Meshkini, Amir; Navidi, Iman; Mahmoudi, Mahmoud; Varmaghani, Mehdi; Mehdipour, Parinaz; Soudi Alamdari, Mahsa; Tayefi, Batool; Naderimagham, Shohreh; Soleymani, Fatemeh; Mesdaghinia, Alireza; Delavari, Alireza; Mohammad, Kazem

    2014-12-01

    This study aimed to evaluate and compare the prediction accuracy of two data mining techniques, including decision tree and neural network models in labeling diagnosis to gastrointestinal prescriptions in Iran. This study was conducted in three phases: data preparation, training phase, and testing phase. A sample from a database consisting of 23 million pharmacy insurance claim records, from 2004 to 2011 was used, in which a total of 330 prescriptions were assessed and used to train and test the models simultaneously. In the training phase, the selected prescriptions were assessed by both a physician and a pharmacist separately and assigned a diagnosis. To test the performance of each model, a k-fold stratified cross validation was conducted in addition to measuring their sensitivity and specificity. Generally, two methods had very similar accuracies. Considering the weighted average of true positive rate (sensitivity) and true negative rate (specificity), the decision tree had slightly higher accuracy in its ability for correct classification (83.3% and 96% versus 80.3% and 95.1%, respectively). However, when the weighted average of ROC area (AUC between each class and all other classes) was measured, the ANN displayed higher accuracies in predicting the diagnosis (93.8% compared with 90.6%). According to the result of this study, artificial neural network and decision tree model represent similar accuracy in labeling diagnosis to GI prescription.

  17. Taking Costs and Diagnostic Test Accuracy into Account When Designing Prevalence Studies: An Application to Childhood Tuberculosis Prevalence.

    PubMed

    Wang, Zhuoyu; Dendukuri, Nandini; Pai, Madhukar; Joseph, Lawrence

    2017-11-01

    When planning a study to estimate disease prevalence to a pre-specified precision, it is of interest to minimize total testing cost. This is particularly challenging in the absence of a perfect reference test for the disease because different combinations of imperfect tests need to be considered. We illustrate the problem and a solution by designing a study to estimate the prevalence of childhood tuberculosis in a hospital setting. All possible combinations of 3 commonly used tuberculosis tests, including chest X-ray, tuberculin skin test, and a sputum-based test, either culture or Xpert, are considered. For each of the 11 possible test combinations, 3 Bayesian sample size criteria, including average coverage criterion, average length criterion and modified worst outcome criterion, are used to determine the required sample size and total testing cost, taking into consideration prior knowledge about the accuracy of the tests. In some cases, the required sample sizes and total testing costs were both reduced when more tests were used, whereas, in other examples, lower costs are achieved with fewer tests. Total testing cost should be formally considered when designing a prevalence study.

  18. How to: evaluate a diagnostic test.

    PubMed

    Leeflang, Mariska M G; Allerberger, Franz

    2018-06-12

    The development of an in vitro diagnostic test from a good idea to a clinically relevant tool takes several steps, with more stringent requirements at every step. This article aims to summarize the necessary questions to be asked about a test and to illustrate study designs answering these questions. We also aim to relate the Regulation (EU) 2017/746 to the needs of evidence-based diagnostic testing, where applicable. We used literature on evidence-based diagnostics, a text book on clinical trials in the development and marketing of medical devices and the English version of Regulation 2017/746 of the European Parliament and of the Council on in vitro diagnostic medical devices. The combination of different test uses and different stages of development determine the required test characteristics and suitability of study designs. In an earlier stage of test development it may be crucial to know whether a test can differentiate diseased persons from healthy controls, while this tells us little about how a test will perform in practice. Later stages focus on the diagnostic accuracy of a test in a clinically relevant situation. However, a test that perfectly distinguishes between patients with and without a certain condition may still have little effect on patient outcomes. Therefore, randomized controlled trials of testing may be needed, as well as post-marketing monitoring. Both researchers and users of tests need to be aware of the limitations of diagnostic test accuracy and realize that accuracy is only indirectly linked to people's health status. Copyright © 2018. Published by Elsevier Ltd.

  19. Validation of a short cognitive battery to screen for fitness-to-drive of people with multiple sclerosis.

    PubMed

    Akinwuntan, A E; Backus, D; Grayson, J; Devos, H

    2018-05-26

    Some symptoms of multiple sclerosis (MS) affect driving. In a recent study, performance on five cognitive tests predicted the on-road test performance of individuals with relapsing-remitting MS with 91% accuracy, 70% sensitivity and 97% specificity. However, the accuracy with which the battery will predict the driving performance of a different cohort that includes all types of MS is unknown. Participants (n = 118; 48 ± 9 years of age; 97 females) performed a comprehensive off-road evaluation that lasted about 3 h and a standardized on-road test that lasted approximately 45 min over a 2-day period within the same week. Performance on the five cognitive tests was used to predict participants' performance on the standardized on-road test. Performance on the five tests together predicted outcome of the on-road test with 82% accuracy, 42% sensitivity and 90% specificity. The accuracy of predicting the on-road performance of a new MS cohort using performance on the battery of five cognitive tests remained very high (82%). The battery, which was administrable in <45 min and cost ~$150, was better at identifying those who actually passed the on-road test (90% specificity). The sensitivity (42%) of the battery indicated that it should not be used as the sole determinant of poor driving-related cognitive skills. A fail performance on the battery should only imply that more comprehensive testing is warranted. © 2018 EAN.

  20. A questionnaire study of cervical cancer screening beliefs and practices of Chinese and Caucasian mother-daughter pairs living in Canada.

    PubMed

    Chang, Sabrina C H; Woo, Jane S T; Gorzalka, Boris B; Brotto, Lori A

    2010-03-01

    Papanicolaou (Pap) testing rates among Chinese women remain low compared with their Caucasian counterparts despite extensive efforts to raise awareness of the importance of regular screening. We examined three potential predictors of Pap testing behaviour in Chinese women: acculturation, cervical cancer screening belief accuracy, and intergenerational transmission. Caucasian (n = 78) and Chinese (n = 93) female university students and their mothers completed questionnaires concerning acculturation, Pap testing beliefs, and behaviours. Ethnic group comparisons revealed that Chinese daughters and mothers had lower Pap testing rates and less accurate beliefs regarding cervical cancer screening. Among women who had had at least one Pap test, there was no ethnic difference in the proportion of women who adhered to the recommended screening frequency. Among the Chinese women, lower heritage acculturation was correlated with higher cancer screening belief accuracy in both the daughters and their mothers. Maternal Pap testing behaviour was predicted by level of cancer screening belief accuracy, whereas daughters' Pap testing behaviour was predicted by previous experience of sexual intercourse and heritage acculturation. No intergenerational transmission of Pap testing beliefs or behaviours was found. The accuracy of cancer screening beliefs, level of acculturation and experience of sexual intercourse may be predictors of Pap testing behaviour in Chinese women. Contrary to our prediction, we found no support for intergenerational transmission, suggesting that Pap testing beliefs and behaviours of Chinese women are independent of the beliefs and behaviours of their mothers.

  1. Meta-analysis: accuracy of rapid tests for malaria in travelers returning from endemic areas.

    PubMed

    Marx, Arthur; Pewsner, Daniel; Egger, Matthias; Nüesch, Reto; Bucher, Heiner C; Genton, Blaise; Hatz, Christoph; Jüni, Peter

    2005-05-17

    Microscopic diagnosis of malaria is unreliable outside specialized centers. Rapid tests have become available in recent years, but their accuracy has not been assessed systematically. To determine the accuracy of rapid diagnostic tests for ruling out malaria in nonimmune travelers returning from malaria-endemic areas. The authors searched MEDLINE, EMBASE, CAB Health, and CINAHL (1988 to September 2004); hand-searched conference proceedings; checked reference lists; and contacted experts and manufacturers. Diagnostic accuracy studies in nonimmune individuals with suspected malaria were included if they compared rapid tests with expert microscopic examination or polymerase chain reaction tests. Data on study and patient characteristics and results were extracted in duplicate. The main outcome was the likelihood ratio for a negative test result (negative likelihood ratio) for Plasmodium falciparum malaria. Likelihood ratios were combined by using random-effects meta-analysis, stratified by the antigen targeted (histidine-rich protein-2 [HRP-2] or parasite lactate dehydrogenase [LDH]) and by test generation. Nomograms of post-test probabilities were constructed. The authors included 21 studies and 5747 individuals. For P. falciparum, HRP-2-based tests were more accurate than parasite LDH-based tests: Negative likelihood ratios were 0.08 and 0.13, respectively (P = 0.019 for difference). Three-band HRP-2 tests had similar negative likelihood ratios but higher positive likelihood ratios compared with 2-band tests (34.7 vs. 98.5; P = 0.003). For P. vivax, negative likelihood ratios tended to be closer to 1.0 for HRP-2-based tests than for parasite LDH-based tests (0.24 vs. 0.13; P = 0.22), but analyses were based on a few heterogeneous studies. Negative likelihood ratios for the diagnosis of P. malariae or P. ovale were close to 1.0 for both types of tests. In febrile travelers returning from sub-Saharan Africa, the typical probability of P. falciparum malaria is estimated at 1.1% (95% CI, 0.6% to 1.9%) after a negative 3-band HRP-2 test result and 97% (CI, 92% to 99%) after a positive test result. Few studies evaluated 3-band HRP-2 tests. The evidence is also limited for species other than P. falciparum because of the few available studies and their more heterogeneous results. Further studies are needed to determine whether the use of rapid diagnostic tests improves outcomes in returning travelers with suspected malaria. Rapid malaria tests may be a useful diagnostic adjunct to microscopy in centers without major expertise in tropical medicine. Initial decisions on treatment initiation and choice of antimalarial drugs can be based on travel history and post-test probabilities after rapid testing. Expert microscopy is still required for species identification and confirmation.

  2. A systematic review and meta-analysis of the diagnostic accuracy of point-of-care tests for the detection of hyperketonemia in dairy cows.

    PubMed

    Tatone, Elise H; Gordon, Jessica L; Hubbs, Jessie; LeBlanc, Stephen J; DeVries, Trevor J; Duffield, Todd F

    2016-08-01

    Several rapid tests for use on farm have been validated for the detection of hyperketonemia (HK) in dairy cattle, however the reported sensitivity and specificity of each method varies and no single study has compared them all. Meta-analysis of diagnostic test accuracy is becoming more common in human medical literature but there are few veterinary examples. The objective of this work was to perform a systematic review and meta-analysis to determine the point-of-care testing method with the highest combined sensitivity and specificity, the optimal threshold for each method, and to identify gaps in the literature. A comprehensive literature search resulted in 5196 references. After removing duplicates and performing relevance screening, 23 studies were included for the qualitative synthesis and 18 for the meta-analysis. The three index tests evaluated in the meta-analysis were: the Precision Xtra(®) handheld device measuring beta-hydroxybutyrate (BHB) concentration in whole blood, and Ketostix(®) and KetoTest(®) semi-quantitative strips measuring the concentration of acetoacetate in urine and BHB in milk, respectively. The diagnostic accuracy of the 3 index tests relative to the reference standard measurement of BHB in serum or whole blood between 1.0-1.4mmol/L was compared using the hierarchical summary receiver operator characteristic (HSROC) method. Subgroup analysis was conducted for each index test to examine the accuracy at different thresholds. The impact of the reference standard threshold, the reference standard method, the prevalence of HK in the population, the primary study source and risk of bias of the primary study was explored using meta-regression. The Precision Xtra(®) device had the highest summary sensitivity in whole blood BHB at 1.2mmol/L, 94.8% (CI95%: 92.6-97.0), and specificity, 97.5% (CI95%: 96.9-98.1). The threshold employed (1.2-1.4mmol/L) did not impact the diagnostic accuracy of the test. The Ketostix(®) and KetoTest(®) strips had the highest summary sensitivity and specificity when the trace and weak positive thresholds were used, respectively. Controlling for the source of publication, HK prevalence and reference standard employed did not impact the estimated sensitivity and specificity of the tests. Including only peer-reviewed studies reduced the number of primary studies evaluating the Precision Xtra(®) by 43% and Ketostix(®) by 33%. Diagnosing HK with blood, urine or milk are valid options, however, the diagnostic inaccuracy of urine and milk should be considered when making economic and treatment decisions. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Diagnostic accuracy of the 14C-urea breath test in Helicobacter pylori infections: a meta-analysis.

    PubMed

    Zhou, Qiaohui; Li, Ling; Ai, Yaowei; Pan, Zhihong; Guo, Mingwen; Han, Jingbo

    2017-01-01

    To summarize and appraise the available literature regarding the use of the 14 C-urea breath test in the diagnosis of Helicobacter pylori infections in adult patients with dyspepsia and to calculate pooled diagnostic accuracy measures. We systematically searched the PubMed, EMBASE, Cochrane Library, Chinese Journals Full-text (CNKI) and CBMDisc databases to identify published data regarding the sensitivity, specificity, and other measures of diagnostic accuracy of the 14 C-urea breath test in the diagnosis of Helicobacter pylori infections in adult patients with dyspeptic symptoms. Risk of bias was assessed using the QUADAS (Quality Assessment of Diagnostic Accuracy Studies)-2 tool. Statistical analyses were performed using Meta-Disc 1.4 software and STATA. Eighteen studies met the inclusion criteria. Pooled results indicated that the  14 C-urea breath test showed a diagnostic sensitivity of 0.96 (95% CI 0.95 to 0.96) and specificity of 0.93 (95% CI 0.91 to 0.94). The positive like ratio (PLR) was 12.27 (95% CI 8.17 to 18.44), the negative like ratio (NLR) was 0.05 (95% CI 0.04 to 0.07), and the area under the curve was 0.985. The DOR was 294.95 (95% CI 178.37 to 487.70). The 14 C-urea breath test showed sufficient sensitivity and specificity for diagnosing Helicobacter pylori infection, but unexplained heterogeneity after meta-regression and several subgroup analyses remained. The UBT has high accuracy for diagnosing H. pylori infections in adult patients with dyspepsia. However, the reliability of these diagnostic meta-analytic estimates is limited by significant heterogeneity due to unknown factors.

  4. Effect of pH Test-Strip Characteristics on Accuracy of Readings.

    PubMed

    Metheny, Norma A; Gunn, Emily M; Rubbelke, Cynthia S; Quillen, Terrilynn Fox; Ezekiel, Uthayashanker R; Meert, Kathleen L

    2017-06-01

    Little is known about characteristics of colorimetric pH test strips that are most likely to be associated with accurate interpretations in clinical situations. To compare the accuracy of 4 pH test strips with varying characteristics (ie, multiple vs single colorimetric squares per calibration, and differing calibration units [1.0 vs 0.5]). A convenience sample of 100 upper-level nursing students with normal color vision was recruited to evaluate the accuracy of the test strips. Six buffer solutions (pH range, 3.0 to 6.0) were used during the testing procedure. Each of the 100 participants performed 20 pH tests in random order, providing a total of 2000 readings. The sensitivity and specificity of each test strip was computed. In addition, the degree to which the test strips under- or overestimated the pH values was analyzed using descriptive statistics. Our criterion for correct readings was an exact match with the pH buffer solution being evaluated. Although none of the test strips evaluated in our study was 100% accurate at all of the measured pH values, those with multiple squares per pH calibration were clearly superior overall to those with a single test square. Test strips with multiple squares per calibration were associated with greater overall accuracy than test strips with a single square per calibration. However, because variable degrees of error were observed in all of the test strips, use of a pH meter is recommended when precise readings are crucial. ©2017 American Association of Critical-Care Nurses.

  5. What do parents know about their children's comprehension of emotions? accuracy of parental estimates in a community sample of pre-schoolers.

    PubMed

    Kårstad, S B; Kvello, O; Wichstrøm, L; Berg-Nielsen, T S

    2014-05-01

    Parents' ability to correctly perceive their child's skills has implications for how the child develops. In some studies, parents have shown to overestimate their child's abilities in areas such as IQ, memory and language. Emotion Comprehension (EC) is a skill central to children's emotion regulation, initially learned from their parents. In this cross-sectional study we first tested children's EC and then asked parents to estimate the child's performance. Thus, a measure of accuracy between child performance and parents' estimates was obtained. Subsequently, we obtained information on child and parent factors that might predict parents' accuracy in estimating their child's EC. Child EC and parental accuracy of estimation was tested by studying a community sample of 882 4-year-olds who completed the Test of Emotion Comprehension (TEC). The parents were instructed to guess their children's responses on the TEC. Predictors of parental accuracy of estimation were child actual performance on the TEC, child language comprehension, observed parent-child interaction, the education level of the parent, and child mental health. Ninety-one per cent of the parents overestimated their children's EC. On average, parents estimated that their 4-year-old children would display the level of EC corresponding to a 7-year-old. Accuracy of parental estimation was predicted by child high performance on the TEC, child advanced language comprehension, and more optimal parent-child interaction. Parents' ability to estimate the level of their child's EC was characterized by a substantial overestimation. The more competent the child, and the more sensitive and structuring the parent was interacting with the child, the more accurate the parent was in the estimation of their child's EC. © 2013 John Wiley & Sons Ltd.

  6. 40 CFR 63.8 - Monitoring requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... in the relevant standard; or (B) The CMS fails a performance test audit (e.g., cylinder gas audit), relative accuracy audit, relative accuracy test audit, or linearity test audit; or (C) The COMS CD exceeds...) Data recording, calculations, and reporting; (v) Accuracy audit procedures, including sampling and...

  7. Diagnostic accuracy of rectal mucosa biopsy testing for chronic wasting disease within white-tailed deer (Odocoileus virginianus) herds in North America:Effects of age,sex,polymorphism at PRNP codon 96,and disease progression

    USDA-ARS?s Scientific Manuscript database

    An effective live animal diagnostic test is needed to assist in the control of chronic wasting disease (CWD), which has spread through captive and wild herds of white-tailed deer (Odocoileus virginianus) in Canada and the United States. In the present study, the diagnostic accuracy of rectal mucosa ...

  8. Picture superiority doubly dissociates the ERP correlates of recollection and familiarity.

    PubMed

    Curran, Tim; Doyle, Jeanne

    2011-05-01

    Two experiments investigated the processes underlying the picture superiority effect on recognition memory. Studied pictures were associated with higher accuracy than studied words, regardless of whether test stimuli were words (Experiment 1) or pictures (Experiment 2). Event-related brain potentials (ERPs) recorded during test suggested that the 300-500 msec FN400 old/new effect, hypothesized to be related to familiarity-based recognition, benefited from study/test congruity, such that it was larger when study and test format remained constant than when they differed. The 500-800 msec parietal old/new effect, hypothesized to be related to recollection, benefited from studying pictures, regardless of test format. The parallel between the accuracy and parietal ERP results suggests that picture superiority may arise from encoding the distinctive attributes of pictures in a manner that enhances their later recollection. Furthermore, when words were tested, opposite effects of studying words versus studying pictures were observed on the FN400 (word > picture) versus parietal (picture > word) old/new effects--providing strong evidence for a crossover interaction between these components that is consistent with a dual-process perspective.

  9. Accuracy evaluation of fluoroscopy-based 2D and 3D pose reconstruction with unicompartmental knee arthroplasty.

    PubMed

    Van Duren, B H; Pandit, H; Beard, D J; Murray, D W; Gill, H S

    2009-04-01

    The recent development in Oxford lateral unicompartmental knee arthroplasty (UKA) design requires a valid method of assessing its kinematics. In particular, the use of single plane fluoroscopy to reconstruct the 3D kinematics of the implanted knee. The method has been used previously to investigate the kinematics of UKA, but mostly it has been used in conjunction with total knee arthroplasty (TKA). However, no accuracy assessment of the method when used for UKA has previously been reported. In this study we performed computer simulation tests to investigate the effect of the different geometry of the unicompartmental implant has on the accuracy of the method in comparison to the total knee implants. A phantom was built to perform in vitro tests to determine the accuracy of the method for UKA. The computer simulations suggested that the use of the method for UKA would prove less accurate than for TKA's. The rotational degrees of freedom for the femur showed greatest disparity between the UKA and TKA. The phantom tests showed that the in-plane translations were accurate to <0.5mm RMS and the out-of-plane translations were less accurate with 4.1mm RMS. The rotational accuracies were between 0.6 degrees and 2.3 degrees which are less accurate than those reported in the literature for TKA, however, the method is sufficient for studying overall knee kinematics.

  10. Does low dose (13)C-urea breath test maintain a satisfactory accuracy in diagnosing Helicobacter pylori infection?

    PubMed

    Coelho, Luiz Gonzaga Vaz; Silva, Arilto Eleutério da; Coelho, Maria Clara de Freitas; Penna, Francisco Guilherme Cancela e; Ferreira, Rafael Otto Antunes; Santa-Cecilia, Elisa Viana

    2011-01-01

    The standard doses of (13)C-urea in (13)C-urea breath test is 75 mg. To assess the diagnostic accuracy of (13)C-urea breath test containing 25 mg of (13)C-urea comparing with the standard doses of 75 mg in the diagnosis of Helicobacter pylori infection. Two hundred seventy adult patients (96 males, 174 females, median age 41 years) performed the standard (13)C-urea breath test (75 mg (13)C-urea) and repeated the (13)C-urea breath test using only 25 mg of (13)C-urea within a 2 week interval. The test was performed using an infrared isotope analyzer. Patients were considered positive if delta over baseline was >4.0‰ at the gold standard test. One hundred sixty-one (59.6%) patients were H. pylori negative and 109 (40.4%) were positive by the gold standard test. Using receiver operating characteristic analysis we established a cut-off value of 3.4% as the best value of 25 mg (13)C-urea breath test to discriminate positive and negative patients, considering the H. pylori prevalence (95% CI: 23.9-37.3) at our setting. Therefore, we obtained to 25 mg (13)C-urea breath test a diagnostic accuracy of 92.9% (95% CI: 88.1-97.9), sensitivity 83.5% (95% CI: 75.4-89.3), specificity 99.4% (95% CI: 96.6-99.9), positive predictive value 98.3% (95% CI: 92.4-99.4), and negative predictive value 93.0% (95% CI: 88.6-96.1). Low-dose (13)C-urea breath test (25 mg (13)C-urea) does not reach accuracy sufficient to be recommended in clinical setting where a 30% prevalence of H. pylori infection is observed. Further studies should be done to determine the diagnostic accuracy of low doses of (13)C-urea in the urea breath test.

  11. QUADAS and STARD: evaluating the quality of diagnostic accuracy studies.

    PubMed

    Oliveira, Maria Regina Fernandes de; Gomes, Almério de Castro; Toscano, Cristiana Maria

    2011-04-01

    To compare the performance of two approaches, one based on the Quality Assessment of Diagnostic Accuracy Studies (QUADAS) and another on the Standards for Reporting Studies of Diagnostic Accuracy (STARD), in evaluating the quality of studies validating the OptiMal® rapid malaria diagnostic test. Articles validating the rapid test published until 2007 were searched in the Medline/PubMed database. This search retrieved 13 articles. A combination of 12 QUADAS criteria and three STARD criteria were compared with the 12 QUADAS criteria alone. Articles that fulfilled at least 50% of QUADAS criteria were considered as regular to good quality. Of the 13 articles retrieved, 12 fulfilled at least 50% of QUADAS criteria, and only two fulfilled the STARD/QUADAS criteria combined. Considering the two criteria combination (> 6 QUADAS and > 3 STARD), two studies (15.4%) showed good methodological quality. The articles selection using the proposed combination resulted in two to eight articles, depending on the number of items assumed as cutoff point. The STARD/QUADAS combination has the potential to provide greater rigor when evaluating the quality of studies validating malaria diagnostic tests, given that it incorporates relevant information not contemplated in the QUADAS criteria alone.

  12. Adaptive time-variant models for fuzzy-time-series forecasting.

    PubMed

    Wong, Wai-Keung; Bai, Enjian; Chu, Alice Wai-Ching

    2010-12-01

    A fuzzy time series has been applied to the prediction of enrollment, temperature, stock indices, and other domains. Related studies mainly focus on three factors, namely, the partition of discourse, the content of forecasting rules, and the methods of defuzzification, all of which greatly influence the prediction accuracy of forecasting models. These studies use fixed analysis window sizes for forecasting. In this paper, an adaptive time-variant fuzzy-time-series forecasting model (ATVF) is proposed to improve forecasting accuracy. The proposed model automatically adapts the analysis window size of fuzzy time series based on the prediction accuracy in the training phase and uses heuristic rules to generate forecasting values in the testing phase. The performance of the ATVF model is tested using both simulated and actual time series including the enrollments at the University of Alabama, Tuscaloosa, and the Taiwan Stock Exchange Capitalization Weighted Stock Index (TAIEX). The experiment results show that the proposed ATVF model achieves a significant improvement in forecasting accuracy as compared to other fuzzy-time-series forecasting models.

  13. Test-Enhanced Learning of Natural Concepts: Effects on Recognition Memory, Classification, and Metacognition

    ERIC Educational Resources Information Center

    Jacoby, Larry L.; Wahlheim, Christopher N.; Coane, Jennifer H.

    2010-01-01

    Three experiments examined testing effects on learning of natural concepts and metacognitive assessments of such learning. Results revealed that testing enhanced recognition memory and classification accuracy for studied and novel exemplars of bird families on immediate and delayed tests. These effects depended on the balance of study and test…

  14. Diagnostic accuracy of enzyme-linked immunosorbent assay (ELISA) and immunoblot (IB) for the detection of antibodies against Neospora caninum in milk from dairy cows.

    PubMed

    Chatziprodromidou, I P; Apostolou, T

    2018-04-01

    The aim of the study was to estimate the sensitivity and specificity of enzyme-linked immunosorbent assay (ELISA) and immunoblot (IB) for detecting antibodies of Neospora caninum in dairy cows, in the absence of a gold standard. The study complies with STRADAS-paratuberculosis guidelines for reporting the accuracy of the test. We tried to apply Bayesian models that do not require conditional independence of the tests under evaluation, but as convergence problems appeared, we used Bayesian methodology, that does not assume conditional dependence of the tests. Informative prior probability distributions were constructed, based on scientific inputs regarding sensitivity and specificity of the IB test and the prevalence of disease in the studied populations. IB sensitivity and specificity were estimated to be 98.8% and 91.3%, respectively, while the respective estimates for ELISA were 60% and 96.7%. A sensitivity analysis, where modified prior probability distributions concerning IB diagnostic accuracy applied, showed a limited effect in posterior assessments. We concluded that ELISA can be used to screen the bulk milk and secondly, IB can be used whenever needed.

  15. 40 CFR 53.53 - Test for flow rate accuracy, regulation, measurement accuracy, and cut-off.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... pressures and temperatures used in the tests and shall be checked at zero and at least one flow rate within...: Equation 5 ER18jy97.067 (ii) To successfully pass the flow rate CV measurement accuracy test, the absolute...

  16. 40 CFR 53.53 - Test for flow rate accuracy, regulation, measurement accuracy, and cut-off.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... pressures and temperatures used in the tests and shall be checked at zero and at least one flow rate within...: Equation 5 ER18jy97.067 (ii) To successfully pass the flow rate CV measurement accuracy test, the absolute...

  17. 40 CFR 53.53 - Test for flow rate accuracy, regulation, measurement accuracy, and cut-off.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... pressures and temperatures used in the tests and shall be checked at zero and at least one flow rate within...: Equation 5 ER18jy97.067 (ii) To successfully pass the flow rate CV measurement accuracy test, the absolute...

  18. 40 CFR 53.53 - Test for flow rate accuracy, regulation, measurement accuracy, and cut-off.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... pressures and temperatures used in the tests and shall be checked at zero and at least one flow rate within...: Equation 5 ER18jy97.067 (ii) To successfully pass the flow rate CV measurement accuracy test, the absolute...

  19. A new method to address verification bias in studies of clinical screening tests: cervical cancer screening assays as an example.

    PubMed

    Xue, Xiaonan; Kim, Mimi Y; Castle, Philip E; Strickler, Howard D

    2014-03-01

    Studies to evaluate clinical screening tests often face the problem that the "gold standard" diagnostic approach is costly and/or invasive. It is therefore common to verify only a subset of negative screening tests using the gold standard method. However, undersampling the screen negatives can lead to substantial overestimation of the sensitivity and underestimation of the specificity of the diagnostic test. Our objective was to develop a simple and accurate statistical method to address this "verification bias." We developed a weighted generalized estimating equation approach to estimate, in a single model, the accuracy (eg, sensitivity/specificity) of multiple assays and simultaneously compare results between assays while addressing verification bias. This approach can be implemented using standard statistical software. Simulations were conducted to assess the proposed method. An example is provided using a cervical cancer screening trial that compared the accuracy of human papillomavirus and Pap tests, with histologic data as the gold standard. The proposed approach performed well in estimating and comparing the accuracy of multiple assays in the presence of verification bias. The proposed approach is an easy to apply and accurate method for addressing verification bias in studies of multiple screening methods. Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Diagnostic accuracy of HLA-B*57:01 screening for the prediction of abacavir hypersensitivity and clinical utility of the test: a meta-analytic review.

    PubMed

    Cargnin, Sarah; Jommi, Claudio; Canonico, Pier Luigi; Genazzani, Armando A; Terrazzino, Salvatore

    2014-05-01

    To determine diagnostic accuracy of HLA-B*57:01 testing for prediction of abacavir-induced hypersensitivity and to quantify the clinical benefit of pretreatment screening through a meta-analytic review of published studies. A comprehensive search was performed up to June 2013. The methodological quality of relevant studies was assessed by the QUADAS-2 tool. The pooled diagnostic estimates were calculated using a random effect model. Despite the presence of heterogeneity in sensitivity or specificity estimates, the pooled diagnostic odds ratio to detect abacavir-induced hypersensitivity on the basis of clinical criteria was 33.07 (95% CI: 22.33-48.97, I(2): 13.9%), while diagnostic odds ratio for detection of immunologically confirmed abacavir hypersensitivity was 1141 (95% CI: 409-3181, I(2): 0%). Pooled analysis of risk ratio showed that prospective HLA-B*57:01 testing significantly reduced the incidence of abacavir-induced hypersensitivity. This meta-analysis demonstrates an excellent diagnostic accuracy of HLA-B*57:01 testing to detect immunologically confirmed abacavir hypersensitivity and corroborates existing recommendations.

  1. The Power Within: The Experimental Manipulation of Power Interacts with Trait BDD Symptoms to Predict Interoceptive Accuracy

    PubMed Central

    Kunstman, Jonathan W.; Clerkin, Elise M.; Palmer, Kateyln; Peters, M. Taylar; Dodd, Dorian R.; Smith, April R.

    2015-01-01

    Background and Objectives This study tested whether relatively low levels of interoceptive accuracy (IAcc) are associated with body dysmorphic disorder (BDD) symptoms. Additionally, given research indicating that power attunes individuals to their internal states, we sought to determine if state interoceptive accuracy could be improved through an experimental manipulation of power. Method Undergraduate women (N = 101) completed a baseline measure of interoceptive accuracy and then were randomized to a power or control condition. Participants were primed with power or a neutral control topic and then completed a post-manipulation measure of state IAcc. Trait BDD symptoms were assessed with a self-report measure. Results Controlling for baseline IAcc, within the control condition, there was a significant inverse relationship between trait BDD symptoms and interoceptive accuracy. Continuing to control for baseline IAcc, within the power condition, there was not a significant relationship between trait BDD symptoms and IAcc, suggesting that power may have attenuated this relationship. At high levels of BDD symptomology, there was also a significant simple effect of experimental condition, such that participants in the power (vs. control) condition had better interoceptive accuracy. These results provide initial evidence that power may positively impact interoceptive accuracy among those with high levels of BDD symptoms. Limitations This cross-sectional study utilized a demographically homogenous sample of women that reflected a broad range of symptoms; thus, although there were a number of participants reporting elevated BDD symptoms, these findings might not generalize to other populations or clinical samples. Conclusions . This study provides the first direct test of the relationship between trait BDD symptoms and IAcc, and provides preliminary evidence that among those with severe BDD symptoms, power may help connect individuals with their internal states. Future research testing the mechanisms linking BDD symptoms with IAcc, as well as how individuals can better connect with their internal experiences is needed. PMID:26295932

  2. The power within: The experimental manipulation of power interacts with trait BDD symptoms to predict interoceptive accuracy.

    PubMed

    Kunstman, Jonathan W; Clerkin, Elise M; Palmer, Kateyln; Peters, M Taylar; Dodd, Dorian R; Smith, April R

    2016-03-01

    This study tested whether relatively low levels of interoceptive accuracy (IAcc) are associated with body dysmorphic disorder (BDD) symptoms. Additionally, given research indicating that power attunes individuals to their internal states, we sought to determine if state interoceptive accuracy could be improved through an experimental manipulation of power.. Undergraduate women (N = 101) completed a baseline measure of interoceptive accuracy and then were randomized to a power or control condition. Participants were primed with power or a neutral control topic and then completed a post-manipulation measure of state IAcc. Trait BDD symptoms were assessed with a self-report measure. Controlling for baseline IAcc, within the control condition, there was a significant inverse relationship between trait BDD symptoms and interoceptive accuracy. Continuing to control for baseline IAcc, within the power condition, there was not a significant relationship between trait BDD symptoms and IAcc, suggesting that power may have attenuated this relationship. At high levels of BDD symptomology, there was also a significant simple effect of experimental condition, such that participants in the power (vs. control) condition had better interoceptive accuracy. These results provide initial evidence that power may positively impact interoceptive accuracy among those with high levels of BDD symptoms.. This cross-sectional study utilized a demographically homogenous sample of women that reflected a broad range of symptoms; thus, although there were a number of participants reporting elevated BDD symptoms, these findings might not generalize to other populations or clinical samples. This study provides the first direct test of the relationship between trait BDD symptoms and IAcc, and provides preliminary evidence that among those with severe BDD symptoms, power may help connect individuals with their internal states. Future research testing the mechanisms linking BDD symptoms with IAcc, as well as how individuals can better connect with their internal experiences is needed.. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Protocol for diagnostic test accuracy study: the efficacy of screening for common dental diseases by Dental Care Professionals

    PubMed Central

    2013-01-01

    Background The bulk of service delivery in dentistry is delivered by general dental practitioners, when a large proportion of patients who attend regularly are asymptomatic and do not require treatment. This represents a substantial and unnecessary cost, given that it is possible to delegate a range of tasks to dental care professionals, who are a less expensive resource. Screening for the common dental diseases by dental care professionals has the potential to release general dental practitioner’s time and increase the capacity to care for those who don't currently access services. The aim of this study is to compare the diagnostic test accuracy of dental care professionals when screening for dental caries and periodontal disease in asymptomatic adults aged eighteen years of age. Methods/design Ten dental practices across the North-West of England will take part in a diagnostic test accuracy study with 200 consecutive patients in each practice. The dental care professionals will act as the index test and the general dental practitioner will act as the reference test. Consenting asymptomatic patients will enter the study and see either the dental care professionals or general dental practitioner first to remove order effects. Both sets of clinicians will make an assessment of dental caries and periodontal disease and enter their decisions on a record sheet for each participant. The primary outcome measure is the diagnostic test accuracy of the dental care professionals and sensitivity, specificity, positive predictive value and negative predictive values will be reported. A number of clinical factors will be assessed for confounding. Discussion The results of this study will determine whether dental care professionals can screen for the two most prevalent oral diseases. This will inform the literature and is apposite given the recent policy change in the United Kingdom towards direct access. PMID:24053760

  4. Test equality between two binary screening tests with a confirmatory procedure restricted on screen positives.

    PubMed

    Lui, Kung-Jong; Chang, Kuang-Chao

    2015-01-01

    In studies of screening accuracy, we may commonly encounter the data in which a confirmatory procedure is administered to only those subjects with screen positives for ethical concerns. We focus our discussion on simultaneously testing equality of sensitivity and specificity between two binary screening tests when only subjects with screen positives receive the confirmatory procedure. We develop four asymptotic test procedures and one exact test procedure. We derive sample size calculation formula for a desired power of detecting a difference at a given nominal [Formula: see text]-level. We employ Monte Carlo simulation to evaluate the performance of these test procedures and the accuracy of the sample size calculation formula developed here in a variety of situations. Finally, we use the data obtained from a study of the prostate-specific-antigen test and digital rectal examination test on 949 Black men to illustrate the practical use of these test procedures and the sample size calculation formula.

  5. Comparative Study on the Different Testing Techniques in Tree Classification for Detecting the Learning Motivation

    NASA Astrophysics Data System (ADS)

    Juliane, C.; Arman, A. A.; Sastramihardja, H. S.; Supriana, I.

    2017-03-01

    Having motivation to learn is a successful requirement in a learning process, and needs to be maintained properly. This study aims to measure learning motivation, especially in the process of electronic learning (e-learning). Here, data mining approach was chosen as a research method. For the testing process, the accuracy comparative study on the different testing techniques was conducted, involving Cross Validation and Percentage Split. The best accuracy was generated by J48 algorithm with a percentage split technique reaching at 92.19 %. This study provided an overview on how to detect the presence of learning motivation in the context of e-learning. It is expected to be good contribution for education, and to warn the teachers for whom they have to provide motivation.

  6. Diagnostic accuracy of clinical tests of the hip: a systematic review with meta-analysis.

    PubMed

    Reiman, Michael P; Goode, Adam P; Hegedus, Eric J; Cook, Chad E; Wright, Alexis A

    2013-09-01

    Hip Physical Examination (HPE) tests have long been used to diagnose a myriad of intra-and extra-articular pathologies of the hip joint. Useful clinical utility is necessary to support diagnostic imaging and subsequent surgical decision making. Summarise and evaluate the current research and utility on the diagnostic accuracy of HPE tests for the hip joint germane to sports related injuries and pathology. A computer-assisted literature search of MEDLINE, CINHAL and EMBASE databases (January 1966 to January 2012) using keywords related to diagnostic accuracy of the hip joint. This systematic review with meta-analysis utilised the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines for the search and reporting phases of the study. Der-Simonian and Laird random effects models were used to summarise sensitivities (SN), specificities (SP), likelihood ratios and diagnostic OR. The employed search strategy revealed 25 potential articles, with 10 demonstrating high quality. Fourteen articles qualified for meta-analysis. The meta-analysis demonstrated that most tests possess weak diagnostic properties with the exception of the patellar-pubic percussion test, which had excellent pooled SN 95 (95% CI 92 to 97%) and good specificity 86 (95% CI 78 to 92%). Several studies have investigated pathology in the hip. Few of the current studies are of substantial quality to dictate clinical decision-making. Currently, only the patellar-pubic percussion test is supported by the data as a stand-alone HPE test. Further studies involving high quality designs are needed to fully assess the value of HPE tests for patients with intra- and extra-articular hip dysfunction.

  7. Accuracy and Precision of Silicon Based Impression Media for Quantitative Areal Texture Analysis

    PubMed Central

    Goodall, Robert H.; Darras, Laurent P.; Purnell, Mark A.

    2015-01-01

    Areal surface texture analysis is becoming widespread across a diverse range of applications, from engineering to ecology. In many studies silicon based impression media are used to replicate surfaces, and the fidelity of replication defines the quality of data collected. However, while different investigators have used different impression media, the fidelity of surface replication has not been subjected to quantitative analysis based on areal texture data. Here we present the results of an analysis of the accuracy and precision with which different silicon based impression media of varying composition and viscosity replicate rough and smooth surfaces. Both accuracy and precision vary greatly between different media. High viscosity media tested show very low accuracy and precision, and most other compounds showed either the same pattern, or low accuracy and high precision, or low precision and high accuracy. Of the media tested, mid viscosity President Jet Regular Body and low viscosity President Jet Light Body (Coltène Whaledent) are the only compounds to show high levels of accuracy and precision on both surface types. Our results show that data acquired from different impression media are not comparable, supporting calls for greater standardisation of methods in areal texture analysis. PMID:25991505

  8. The accuracy of postoperative, non-invasive Air-Test to diagnose atelectasis in healthy patients after surgery: a prospective, diagnostic pilot study.

    PubMed

    Ferrando, Carlos; Romero, Carolina; Tusman, Gerardo; Suarez-Sipmann, Fernando; Canet, Jaume; Dosdá, Rosa; Valls, Paola; Villena, Abigail; Serralta, Ferran; Jurado, Ana; Carrizo, Juan; Navarro, Jose; Parrilla, Cristina; Romero, Jose E; Pozo, Natividad; Soro, Marina; Villar, Jesús; Belda, Francisco Javier

    2017-05-29

    To assess the diagnostic accuracy of peripheral capillary oxygen saturation (SpO 2 ) while breathing room air for 5 min (the 'Air-Test') in detecting postoperative atelectasis. Prospective cohort study. Diagnostic accuracy was assessed by measuring the agreement between the index test and the reference standard CT scan images. Postanaesthetic care unit in a tertiary hospital in Spain. Three hundred and fifty patients from 12 January to 7 February 2015; 170 patients scheduled for surgery under general anaesthesia who were admitted into the postsurgical unit were included. The Air-Test was performed in conscious extubated patients after a 30 min stabilisation period during which they received supplemental oxygen therapy via a venturi mask. The Air-Test was defined as positive when SpO 2 was ≤96% and negative when SpO 2 was ≥97%. Arterial blood gases were measured in all patients at the end of the Air-Test. In the subsequent 25 min, the presence of atelectasis was evaluated by performing a CT scan in 59 randomly selected patients. The primary study outcome was assessment of the accuracy of the Air-Test for detecting postoperative atelectasis compared with the reference standard. The secondary outcome was the incidence of positive Air-Test results. The Air-Test diagnosed postoperative atelectasis with an area under the receiver operating characteristic curve of 0.90 (95% CI 0.82 to 0.98) with a sensitivity of 82.6% and a specificity of 87.8%. The presence of atelectasis was confirmed by CT scans in all patients (30/30) with positive and in 5 patients (17%) with negative Air-Test results. Based on the Air-Test, postoperative atelectasis was present in 36% of the patients (62 out of 170). The Air-Test may represent an accurate, simple, inexpensive and non-invasive method for diagnosing postoperative atelectasis. NCT02650037. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  9. Accuracy and eligibility of CBCT to digitize dental plaster casts.

    PubMed

    Becker, Kathrin; Schmücker, Ulf; Schwarz, Frank; Drescher, Dieter

    2018-05-01

    Software-based dental planning requires digital casts and oftentimes cone-beam computed tomography (CBCT) radiography. However, buying a dedicated model digitizing device can be expensive and might not be required. The present study aimed to assess whether digital models derived from CBCT and models digitized using a dedicated optical device are of comparable accuracy. A total of 20 plaster casts were digitized with eight CBCT and five optical model digitizers. Corresponding models were superimposed using six control points and subsequent iterative closest point matching. Median distances were calculated among all registered models. Data were pooled per scanner and model. Boxplots were generated, and the paired t test, a Friedman test, and a post-hoc Nemenyi test were employed for statistical comparison. Results were found significant at p < 0.05. All CBCT devices allowed the digitization of plaster casts, but failed to reach the accuracy of the dedicated model digitizers (p < 0.001). Median distances between CBCT and optically digitized casts were 0.064 + - 0.005 mm. Qualitative differences among the CBCT systems were detected (χ 2  = 78.07, p < 0.001), and one CBCT providing a special plaster cast digitization mode was found superior to the competitors (p < 0.05). CBCT systems failed to reach the accuracy from optical digitizers, but within the limits of the study, accuracy appeared to be sufficient for digital planning and forensic purposes. Most CBCT systems enabled digitization of plaster casts, and accuracy was found sufficient for digital planning and storage purposes.

  10. Accuracy of Four Imaging Techniques for Diagnosis of Posterior Pelvic Floor Disorders.

    PubMed

    van Gruting, Isabelle M A; Stankiewicz, Aleksandra; Kluivers, Kirsten; De Bin, Riccardo; Blake, Helena; Sultan, Abdul H; Thakar, Ranee

    2017-11-01

    To establish the diagnostic test accuracy of evacuation proctography, magnetic resonance imaging (MRI), transperineal ultrasonography, and endovaginal ultrasonography for detecting posterior pelvic floor disorders (rectocele, enterocele, intussusception, and anismus) in women with obstructed defecation syndrome and secondarily to identify the most patient-friendly imaging technique. In this prospective cohort study, 131 women with symptoms of obstructed defecation syndrome underwent evacuation proctogram, MRI, and transperineal and endovaginal ultrasonography. Images were analyzed by two blinded observers. In the absence of a reference standard, latent class analysis was used to assess diagnostic test accuracy of multiple tests with area under the curve (AUC) as the primary outcome measure. Secondary outcome measures were interobserver agreement calculated as Cohen's κ and patient acceptability using a visual analog scale. No significant differences in diagnostic accuracy were found among the imaging techniques for all the target conditions. Estimates of diagnostic test accuracy were highest for rectocele using MRI (AUC 0.79) or transperineal ultrasonography (AUC 0.85), for enterocele using transperineal (AUC 0.73) or endovaginal ultrasonography (AUC 0.87), for intussusception using evacuation proctography (AUC 0.76) or endovaginal ultrasonography (AUC 0.77), and for anismus using endovaginal (AUC 0.95) or transperineal ultrasonography (AUC 0.78). Interobserver agreement for the diagnosis of rectocele (κ 0.53-0.72), enterocele (κ 0.54-0.94) and anismus (κ 0.43-0.81) was moderate to excellent, but poor to fair for intussusception (κ -0.03 to 0.37) with all techniques. Patient acceptability was better for transperineal and endovaginal ultrasonography as compared with MRI and evacuation proctography (P<.001). Evacuation proctography, MRI, and transperineal and endovaginal ultrasonography were shown to have similar diagnostic test accuracy. Evacuation proctography is not the best available imaging technique. There is no one optimal test for the diagnosis of all posterior pelvic floor disorders. Because transperineal and endovaginal ultrasonography have good test accuracy and patient acceptability, we suggest these could be used for initial assessment of obstructed defecation syndrome. ClinicalTrials.gov, NCT02239302.

  11. Administrative database code accuracy did not vary notably with changes in disease prevalence.

    PubMed

    van Walraven, Carl; English, Shane; Austin, Peter C

    2016-11-01

    Previous mathematical analyses of diagnostic tests based on the categorization of a continuous measure have found that test sensitivity and specificity varies significantly by disease prevalence. This study determined if the accuracy of diagnostic codes varied by disease prevalence. We used data from two previous studies in which the true status of renal disease and primary subarachnoid hemorrhage, respectively, had been determined. In multiple stratified random samples from the two previous studies having varying disease prevalence, we measured the accuracy of diagnostic codes for each disease using sensitivity, specificity, and positive and negative predictive value. Diagnostic code sensitivity and specificity did not change notably within clinically sensible disease prevalence. In contrast, positive and negative predictive values changed significantly with disease prevalence. Disease prevalence had no important influence on the sensitivity and specificity of diagnostic codes in administrative databases. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Screening for Syphilis: Updated Evidence Report and Systematic Review for the US Preventive Services Task Force.

    PubMed

    Cantor, Amy G; Pappas, Miranda; Daeges, Monica; Nelson, Heidi D

    2016-06-07

    Screening for syphilis infection is currently recommended for high-risk individuals, including those with previous syphilis infection, an infected sexual partner, HIV infection, or more than 4 sex partners in the preceding year. To update a 2004 systematic review of studies of syphilis screening effectiveness, test accuracy, and screening harms in nonpregnant adults and adolescents. Cochrane Central Register of Controlled Trials and Cochrane Database of Systematic Reviews through October 2015 and Ovid MEDLINE (January 2004 to October 2015), with updated search through March 2016. English-language trials and observational studies of screening effectiveness, test accuracy, and screening harms in nonpregnant adults and adolescents. One investigator abstracted data, a second checked data for accuracy, and 2 investigators independently assessed study quality using predefined criteria. Transmission of disease, including HIV; complications of syphilis; diagnostic accuracy; and harms of screening. No evidence was identified regarding the effectiveness of screening on clinical outcomes or the effectiveness of risk assessment instruments; the harms of screening; or the effectiveness of screening in average-risk, nonpregnant adolescents or adults or high-risk individuals other than men who have sex with men (MSM) or men who are HIV positive. Four non-US studies indicated higher rates of syphilis detection with screening every 3 months vs 6 or 12 months for early syphilis in HIV-positive men or MSM. For example, there was an increased proportion of asymptomatic, higher-risk MSM in Australia (n = 6789 consultations) receiving a diagnosis of early syphilis when tested every 3 months vs annually (53% vs 16%, P = .001), but no difference among low-risk MSM. Treponemal and nontreponemal tests were accurate in asymptomatic individuals (sensitivity >85%, specificity >91%) in 3 studies but required confirmatory testing. Reverse sequence testing with an initial automated treponemal test yielded more false reactive test results than with rapid plasma reagin in 2 studies, one with a low-prevalence US population (0.6% vs 0.0%, P = .03) and another in a higher-prevalence Canadian population (0.26% vs 0.13%). Screening HIV-positive men or MSM for syphilis every 3 months is associated with improved syphilis detection. Treponemal or nontreponemal tests are accurate screening tests but require confirmation. Research is needed on the effect of screening on clinical outcomes; effective screening strategies, including reverse sequence screening, in various patient populations; and harms of screening.

  13. Accuracy of biochemical markers for predicting nasogastric tube placement in adults--a systematic review of diagnostic studies.

    PubMed

    Fernandez, Ritin S; Chau, Janita Pak-Chun; Thompson, David R; Griffiths, Rhonda; Lo, Hoi-Shan

    2010-08-01

    The objective of this study was to investigate the diagnostic performance of biochemical tests used to determine placement of nasogastric (NG) tubes after insertion in adults. A systematic review of diagnostic studies was undertaken. A literature search of the bibliographic databases and the World Wide Web was performed to locate original diagnostic studies in English or Chinese on biochemical markers for detecting NG tube location. Studies in which one or more different tests were evaluated with a reference standard, and diagnostic values were reported or could be calculated were included. Two reviewers independently checked all abstracts and full text studies for inclusion criteria. Included studies were assessed for their quality using the QUADAS tool. Study features and diagnostic values were extracted from the included studies. Of the 10 studies included in this review, seven investigated the diagnostic accuracy of pH, one investigated the diagnostic accuracy of pH and bilirubin respectively, two a combination of pH and bilirubin and one a combination of pH, pepsin and trypsin levels in identifying NG tube location. All studies used X-rays as the reference standard for comparison. Pooled results demonstrated that a pH of

  14. Diagnostic validation of three test methods for detection of cyprinid herpesvirus 3 (CyHV-3).

    PubMed

    Clouthier, Sharon C; McClure, Carol; Schroeder, Tamara; Desai, Megan; Hawley, Laura; Khatkar, Sunita; Lindsay, Melissa; Lowe, Geoff; Richard, Jon; Anderson, Eric D

    2017-03-06

    Cyprinid herpesvirus 3 (CyHV-3) is the aetiological agent of koi herpesvirus disease in koi and common carp. The disease is notifiable to the World Organisation for Animal Health. Three tests-quantitative polymerase chain reaction (qPCR), conventional PCR (cPCR) and virus isolation by cell culture (VI)-were validated to assess their fitness as diagnostic tools for detection of CyHV-3. Test performance metrics of diagnostic accuracy were sensitivity (DSe) and specificity (DSp). Repeatability and reproducibility were measured to assess diagnostic precision. Estimates of test accuracy, in the absence of a gold standard reference test, were generated using latent class models. Test samples originated from wild common carp naturally exposed to CyHV-3 or domesticated koi either virus free or experimentally infected with the virus. Three laboratories in Canada participated in the precision study. Moderate to high repeatability (81 to 99%) and reproducibility (72 to 97%) were observed for the qPCR and cPCR tests. The lack of agreement observed between some of the PCR test pair results was attributed to cross-contamination of samples with CyHV-3 nucleic acid. Accuracy estimates for the PCR tests were 99% for DSe and 93% for DSp. Poor precision was observed for the VI test (4 to 95%). Accuracy estimates for VI/qPCR were 90% for DSe and 88% for DSp. Collectively, the results show that the CyHV-3 qPCR test is a suitable tool for surveillance, presumptive diagnosis and certification of individuals or populations as CyHV-3 free.

  15. Accuracy of dengue clinical diagnosis with and without NS1 antigen rapid test: Comparison between human and Bayesian network model decision.

    PubMed

    Sa-Ngamuang, Chaitawat; Haddawy, Peter; Luvira, Viravarn; Piyaphanee, Watcharapong; Iamsirithaworn, Sopon; Lawpoolsri, Saranath

    2018-06-18

    Differentiating dengue patients from other acute febrile illness patients is a great challenge among physicians. Several dengue diagnosis methods are recommended by WHO. The application of specific laboratory tests is still limited due to high cost, lack of equipment, and uncertain validity. Therefore, clinical diagnosis remains a common practice especially in resource limited settings. Bayesian networks have been shown to be a useful tool for diagnostic decision support. This study aimed to construct Bayesian network models using basic demographic, clinical, and laboratory profiles of acute febrile illness patients to diagnose dengue. Data of 397 acute undifferentiated febrile illness patients who visited the fever clinic of the Bangkok Hospital for Tropical Diseases, Thailand, were used for model construction and validation. The two best final models were selected: one with and one without NS1 rapid test result. The diagnostic accuracy of the models was compared with that of physicians on the same set of patients. The Bayesian network models provided good diagnostic accuracy of dengue infection, with ROC AUC of 0.80 and 0.75 for models with and without NS1 rapid test result, respectively. The models had approximately 80% specificity and 70% sensitivity, similar to the diagnostic accuracy of the hospital's fellows in infectious disease. Including information on NS1 rapid test improved the specificity, but reduced the sensitivity, both in model and physician diagnoses. The Bayesian network model developed in this study could be useful to assist physicians in diagnosing dengue, particularly in regions where experienced physicians and laboratory confirmation tests are limited.

  16. Performance of a new test strip for freestyle blood glucose monitoring systems.

    PubMed

    Lock, John Paul; Brazg, Ronald; Bernstein, Robert M; Taylor, Elizabeth; Patel, Mona; Ward, Jeanne; Alva, Shridhara; Chen, Ting; Welsh, Zoë; Amor, Walter; Bhogal, Claire; Ng, Ronald

    2011-01-01

    a new strip, designed to enhance the ease of use and minimize interference of non-glucose sugars, has been developed to replace the current FreeStyle (Abbott Diabetes Care, Alameda, CA) blood glucose test strip. We evaluated the performance of this new strip. laboratory evaluation included precision, linearity, dynamic range, effects of operating temperature, humidity, altitude, hematocrit, interferents, and blood reapplication. System accuracy, lay user performance, and ease of use for finger capillary blood testing and accuracy for venous blood testing were evaluated at clinics. Lay users also compared the speed and ease of use between the new strip and the current FreeStyle strip. for glucose concentrations <75 mg/dL, 73%, 100%, and 100% of the individual capillary blood glucose results obtained by lay users fell within ± 5, 10, and 15 mg/dL, respectively, of the reference. For glucose concentrations ≥75 mg/dL, 68%, 95%, 99%, and 99% of the lay user results fell within  ±  5%, 10%, 15%, and 20%, respectively, of the reference. Comparable accuracy was obtained in the venous blood study. Lay users found the new test strip easy to use and faster and easier to use than the current FreeStyle strip. The new strip maintained accuracy under various challenging conditions, including high concentrations of various interferents, sample reapplication up to 60 s, and extremes in hematocrit, altitude, and operating temperature and humidity. our results demonstrated excellent accuracy of the new FreeStyle test strip and validated the improvements in minimizing interference and enhancing ease of use.

  17. A multimodality imaging-compatible insertion robot with a respiratory motion calibration module designed for ablation of liver tumors: a preclinical study.

    PubMed

    Li, Dongrui; Cheng, Zhigang; Chen, Gang; Liu, Fangyi; Wu, Wenbo; Yu, Jie; Gu, Ying; Liu, Fengyong; Ren, Chao; Liang, Ping

    2018-04-03

    To test the accuracy and efficacy of the multimodality imaging-compatible insertion robot with a respiratory motion calibration module designed for ablation of liver tumors in phantom and animal models. To evaluate and compare the influences of intervention experience on robot-assisted and ultrasound-controlled ablation procedures. Accuracy tests on rigid body/phantom model with a respiratory movement simulation device and microwave ablation tests on porcine liver tumor/rabbit liver cancer were performed with the robot we designed or with the traditional ultrasound-guidance by physicians with or without intervention experience. In the accuracy tests performed by the physicians without intervention experience, the insertion accuracy and efficiency of robot-assisted group was higher than those of ultrasound-guided group with statistically significant differences. In the microwave ablation tests performed by the physicians without intervention experience, better complete ablation rate was achieved when applying the robot. In the microwave ablation tests performed by the physicians with intervention experience, there was no statistically significant difference of the insertion number and total ablation time between the robot-assisted group and the ultrasound-controlled group. The evaluation by the NASA-TLX suggested that the robot-assisted insertion and microwave ablation process performed by physicians with or without experience were more comfortable. The multimodality imaging-compatible insertion robot with a respiratory motion calibration module designed for ablation of liver tumors could increase the insertion accuracy and ablation efficacy, and minimize the influence of the physicians' experience. The ablation procedure could be more comfortable with less stress with the application of the robot.

  18. Screening of hearing in elderly people: assessment of accuracy and reproducibility of the whispered voice test.

    PubMed

    Labanca, Ludimila; Guimarães, Fernando Sales; Costa-Guarisco, Letícia Pimenta; Couto, Erica de Araújo Brandão; Gonçalves, Denise Utsch

    2017-11-01

    Given the high prevalence of presbycusis and its detrimental effect on quality of life, screening tests can be useful tools for detecting hearing loss in primary care settings. This study therefore aimed to determine the accuracy and reproducibility of the whispered voice test as a screening method for detecting hearing impairment in older people. This cross-sectional study was carried out with 210 older adults aged between 60 and 97 years who underwent the whispered voice test employing ten different phrases and using audiometry as a reference test. Sensitivity, specificity and positive and negative predictive values were calculated and accuracy was measured by calculating the area under the ROC curve. The test was repeated on 20% of the ears by a second examiner to assess inter-examiner reproducibility (IER). The words and phrases that showed the highest area under the curve (AUC) and IER values were: "shoe" (AUC = 0.918; IER = 0.877), "window" (AUC = 0.917; IER = 0.869), "it looks like it's going to rain" (AUC = 0.911; IER = 0.810), and "the bus is late" (AUC = 0.900; IER = 0.810), demonstrating that the whispered voice test is a useful screening tool for detecting hearing loss among older people. It is proposed that these words and phrases should be incorporated into the whispered voice test protocol.

  19. The diagnostic accuracy of 1.5T magnetic resonance imaging for detecting root avulsions in traumatic adult brachial plexus injuries.

    PubMed

    Wade, Ryckie G; Itte, Vinay; Rankine, James J; Ridgway, John P; Bourke, Grainne

    2018-03-01

    Identification of root avulsions is of critical importance in traumatic brachial plexus injuries because it alters the reconstruction and prognosis. Pre-operative magnetic resonance imaging is gaining popularity, but there is limited and conflicting data on its diagnostic accuracy for root avulsion. This cohort study describes consecutive patients requiring brachial plexus exploration following trauma between 2008 and 2016. The index test was magnetic resonance imaging at 1.5 Tesla and the reference test was operative exploration of the supraclavicular plexus. Complete data from 29 males was available. The diagnostic accuracy of magnetic resonance imaging for root avulsion(s) of C5-T1 was 79%. The diagnostic accuracy of a pseudomeningocoele as a surrogate marker of root avulsion(s) of C5-T1 was 68%. We conclude that pseudomeningocoles were not a reliable sign of root avulsion and magnetic resonance imaging has modest diagnostic accuracy for root avulsions in the context of adult traumatic brachial plexus injuries. III.

  20. Self-audit of lockout/tagout in manufacturing workplaces: A pilot study.

    PubMed

    Yamin, Samuel C; Parker, David L; Xi, Min; Stanley, Rodney

    2017-05-01

    Occupational health and safety (OHS) self-auditing is a common practice in industrial workplaces. However, few audit instruments have been tested for inter-rater reliability and accuracy. A lockout/tagout (LOTO) self-audit checklist was developed for use in manufacturing enterprises. It was tested for inter-rater reliability and accuracy using responses of business self-auditors and external auditors. Inter-rater reliability at ten businesses was excellent (κ = 0.84). Business self-auditors had high (100%) accuracy in identifying elements of LOTO practice that were present as well those that were absent (81% accuracy). Reliability and accuracy increased further when problematic checklist questions were removed from the analysis. Results indicate that the LOTO self-audit checklist would be useful in manufacturing firms' efforts to assess and improve their LOTO programs. In addition, a reliable self-audit instrument removes the need for external auditors to visit worksites, thereby expanding capacity for outreach and intervention while minimizing costs. © 2017 Wiley Periodicals, Inc.

  1. Tourniquet Test for Dengue Diagnosis: Systematic Review and Meta-analysis of Diagnostic Test Accuracy.

    PubMed

    Grande, Antonio Jose; Reid, Hamish; Thomas, Emma; Foster, Charlie; Darton, Thomas C

    2016-08-01

    Dengue fever is a ubiquitous arboviral infection in tropical and sub-tropical regions, whose incidence has increased over recent decades. In the absence of a rapid point of care test, the clinical diagnosis of dengue is complex. The World Health Organisation has outlined diagnostic criteria for making the diagnosis of dengue infection, which includes the use of the tourniquet test (TT). To assess the quality of the evidence supporting the use of the TT and perform a diagnostic accuracy meta-analysis comparing the TT to antibody response measured by ELISA. A comprehensive literature search was conducted in the following databases to April, 2016: MEDLINE (PubMed), EMBASE, Cochrane Central Register of Controlled Trials, BIOSIS, Web of Science, SCOPUS. Studies comparing the diagnostic accuracy of the tourniquet test with ELISA for the diagnosis of dengue were included. Two independent authors extracted data using a standardized form. A total of 16 studies with 28,739 participants were included in the meta-analysis. Pooled sensitivity for dengue diagnosis by TT was 58% (95% Confidence Interval (CI), 43%-71%) and the specificity was 71% (95% CI, 60%-80%). In the subgroup analysis sensitivity for non-severe dengue diagnosis was 55% (95% CI, 52%-59%) and the specificity was 63% (95% CI, 60%-66%), whilst sensitivity for dengue hemorrhagic fever diagnosis was 62% (95% CI, 53%-71%) and the specificity was 60% (95% CI, 48%-70%). Receiver-operator characteristics demonstrated a test accuracy (AUC) of 0.70 (95% CI, 0.66-0.74). The tourniquet test is widely used in resource poor settings despite currently available evidence demonstrating only a marginal benefit in making a diagnosis of dengue infection alone. The protocol for this systematic review was registered at CRD42015020323.

  2. Coefficient of Friction Patterns Can Identify Damage in Native and Engineered Cartilage Subjected to Frictional-Shear Stress

    PubMed Central

    Whitney, G. A.; Mansour, J. M.; Dennis, J. E.

    2015-01-01

    The mechanical loading environment encountered by articular cartilage in situ makes frictional-shear testing an invaluable technique for assessing engineered cartilage. Despite the important information that is gained from this testing, it remains under-utilized, especially for determining damage behavior. Currently, extensive visual inspection is required to assess damage; this is cumbersome and subjective. Tools to simplify, automate, and remove subjectivity from the analysis may increase the accessibility and usefulness of frictional-shear testing as an evaluation method. The objective of this study was to determine if the friction signal could be used to detect damage that occurred during the testing. This study proceeded in two phases: first, a simplified model of biphasic lubrication that does not require knowledge of interstitial fluid pressure was developed. In the second phase, frictional-shear tests were performed on 74 cartilage samples, and the simplified model was used to extract characteristic features from the friction signals. Using support vector machine classifiers, the extracted features were able to detect damage with a median accuracy of approximately 90%. The accuracy remained high even in samples with minimal damage. In conclusion, the friction signal acquired during frictional-shear testing can be used to detect resultant damage to a high level of accuracy. PMID:25691395

  3. Evidence on the Effectiveness of Comprehensive Error Correction in Second Language Writing

    ERIC Educational Resources Information Center

    Van Beuningen, Catherine G.; De Jong, Nivja H.; Kuiken, Folkert

    2012-01-01

    This study investigated the effect of direct and indirect comprehensive corrective feedback (CF) on second language (L2) learners' written accuracy (N = 268). The study set out to explore the value of CF as a revising tool as well as its capacity to support long-term accuracy development. In addition, we tested Truscott's (e.g., 2001, 2007) claims…

  4. Fecal electrolyte testing for evaluation of unexplained diarrhea: Validation of body fluid test accuracy in the absence of a reference method.

    PubMed

    Voskoboev, Nikolay V; Cambern, Sarah J; Hanley, Matthew M; Giesen, Callen D; Schilling, Jason J; Jannetto, Paul J; Lieske, John C; Block, Darci R

    2015-11-01

    Validation of tests performed on body fluids other than blood or urine can be challenging due to the lack of a reference method to confirm accuracy. The aim of this study was to evaluate alternate assessments of accuracy that laboratories can rely on to validate body fluid tests in the absence of a reference method using the example of sodium (Na(+)), potassium (K(+)), and magnesium (Mg(2+)) testing in stool fluid. Validations of fecal Na(+), K(+), and Mg(2+) were performed on the Roche cobas 6000 c501 (Roche Diagnostics) using residual stool specimens submitted for clinical testing. Spiked recovery, mixing studies, and serial dilutions were performed and % recovery of each analyte was calculated to assess accuracy. Results were confirmed by comparison to a reference method (ICP-OES, PerkinElmer). Mean recoveries for fecal electrolytes were Na(+) upon spiking=92%, mixing=104%, and dilution=105%; K(+) upon spiking=94%, mixing=96%, and dilution=100%; and Mg(2+) upon spiking=93%, mixing=98%, and dilution=100%. When autoanalyzer results were compared to reference ICP-OES results, Na(+) had a slope=0.94, intercept=4.1, and R(2)=0.99; K(+) had a slope=0.99, intercept=0.7, and R(2)=0.99; and Mg(2+) had a slope=0.91, intercept=-4.6, and R(2)=0.91. Calculated osmotic gap using both methods were highly correlated with slope=0.95, intercept=4.5, and R(2)=0.97. Acid pretreatment increased magnesium recovery from a subset of clinical specimens. A combination of mixing, spiking, and dilution recovery experiments are an acceptable surrogate for assessing accuracy in body fluid validations in the absence of a reference method. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  5. Accuracy, risk and the intrinsic value of diagnostic imaging: a review of the cost-utility literature.

    PubMed

    Otero, Hansel J; Fang, Chi H; Sekar, Meera; Ward, Robert J; Neumann, Peter J

    2012-05-01

    The aim of this study was to systematically review the reporting of the value of imaging unrelated to treatment consequences and test characteristics in all imaging-related published cost-utility analyses (CUAs) in the medical literature. All CUAs published between 1976 and 2008 evaluating diagnostic imaging technologies contained in the CEA Registry, a publicly available comprehensive database of health related CUAs, were screened. Publication characteristics, imaging modality, and the inclusion of test characteristics including accuracy, costs, risks, and the potential value unrelated to treatment consequences (eg, reassurance or anxiety) were assessed. Ninety-six published CUAs evaluating 155 different imaging technologies were included in the final sample; 27 studies were published in imaging-specialized journals. Fifty-two studies (54%) evaluated the performance of a single imaging modality, while 44 studies (46%) compared two or more different imaging modalities. The most common areas of interest were cardiovascular (45%) and neuroradiology (17%). Forty-two technologies (27%) concerned ultrasound, while 34 (22%) concerned magnetic resonance. Seventy-nine (51%) technologies used ionizing radiation. Test accuracy was reported or calculated for 90% (n = 133 and n = 5, respectively) and assumed perfect (reference test or gold-standard test without alternative testing strategy to capture false-negatives and false-positives) for 8% (n = 12) of technologies. Only 22 studies (23%) assessing 40 imaging technologies (26%) considered inconclusive or indeterminate results. The risk of testing was reported for 32 imaging technologies (21%). Fifteen studies (16%) considered the value of diagnostic imaging unrelated to treatment. Four studies incorporated it as quality-of-life adjustments, while 10 studies mentioned it only in their discussions or as a limitation. The intrinsic value of imaging (the value of imaging unrelated to treatment) has not been appropriately defined or incorporated in the existing cost-utility literature, which could be due to a lack of evidence on the issue. Thus, more research is needed on metrics for a more comprehensive evaluation of diagnostic imaging. Similarly, the incorporation of variations in imaging tests accuracy, inconclusive results and associated risks has lacked uniformity in the cost-utility literature. Acknowledgment of these characteristics in future cost-utility publications will enhance their value and provide results that more closely resemble routine clinical practice. Copyright © 2012 AUR. Published by Elsevier Inc. All rights reserved.

  6. Gradient Calculation Methods on Arbitrary Polyhedral Unstructured Meshes for Cell-Centered CFD Solvers

    NASA Technical Reports Server (NTRS)

    Sozer, Emre; Brehm, Christoph; Kiris, Cetin C.

    2014-01-01

    A survey of gradient reconstruction methods for cell-centered data on unstructured meshes is conducted within the scope of accuracy assessment. Formal order of accuracy, as well as error magnitudes for each of the studied methods, are evaluated on a complex mesh of various cell types through consecutive local scaling of an analytical test function. The tests highlighted several gradient operator choices that can consistently achieve 1st order accuracy regardless of cell type and shape. The tests further offered error comparisons for given cell types, leading to the observation that the "ideal" gradient operator choice is not universal. Practical implications of the results are explored via CFD solutions of a 2D inviscid standing vortex, portraying the discretization error properties. A relatively naive, yet largely unexplored, approach of local curvilinear stencil transformation exhibited surprisingly favorable properties

  7. Assessing the dependence of sensitivity and specificity on prevalence in meta-analysis

    PubMed Central

    Li, Jialiang; Fine, Jason P.

    2011-01-01

    We consider modeling the dependence of sensitivity and specificity on the disease prevalence in diagnostic accuracy studies. Many meta-analyses compare test accuracy across studies and fail to incorporate the possible connection between the accuracy measures and the prevalence. We propose a Pearson type correlation coefficient and an estimating equation–based regression framework to help understand such a practical dependence. The results we derive may then be used to better interpret the results from meta-analyses. In the biomedical examples analyzed in this paper, the diagnostic accuracy of biomarkers are shown to be associated with prevalence, providing insights into the utility of these biomarkers in low- and high-prevalence populations. PMID:21525421

  8. Influence of impression technique and material on the accuracy of multiple implant impressions.

    PubMed

    Wöstmann, Bernd; Rehmann, Peter; Balkenhol, Markus

    2008-01-01

    This study aimed to analyze the influence of impression technique (pick-up versus reposition) and material on the accuracy of the working cast. Sixty impressions were made with 3 materials from a master cast with 4 XiVE implants. The changes in the implant axis direction, rotation, and 3-dimensional shift were assessed. The pick-up technique showed significantly (P < .05, U test) lower values for axis direction and 3D shift but higher values for rotation than the reposition technique. The differences between the materials were not significant (P > .05, H test). It can be concluded that the impression technique-in contrast to the impression material-has a significant influence on transfer accuracy.

  9. A Test Suite for 3D Radiative Hydrodynamics Simulations of Protoplanetary Disks

    NASA Astrophysics Data System (ADS)

    Boley, Aaron C.; Durisen, R. H.; Nordlund, A.; Lord, J.

    2006-12-01

    Radiative hydrodynamics simulations of protoplanetary disks with different treatments for radiative cooling demonstrate disparate evolutions (see Durisen et al. 2006, PPV chapter). Some of these differences include the effects of convection and metallicity on disk cooling and the susceptibility of the disk to fragmentation. Because a principal reason for these differences may be the treatment of radiative cooling, the accuracy of cooling algorithms must be evaluated. In this paper we describe a radiative transport test suite, and we challenge all researchers who use radiative hydrodynamics to study protoplanetary disk evolution to evaluate their algorithms with these tests. The test suite can be used to demonstrate an algorithm's accuracy in transporting the correct flux through an atmosphere and in reaching the correct temperature structure, to test the algorithm's dependence on resolution, and to determine whether the algorithm permits of inhibits convection when expected. In addition, we use this test suite to demonstrate the accuracy of a newly developed radiative cooling algorithm that combines vertical rays with flux-limited diffusion. This research was supported in part by a Graduate Student Researchers Program fellowship.

  10. People use the memory for past-test heuristic as an explicit cue for judgments of learning.

    PubMed

    Serra, Michael J; Ariel, Robert

    2014-11-01

    When people estimate their memory for to-be-learned material over multiple study-test trials, they tend to base their judgments of learning (JOLs) on their test performance for those materials on the previous trial. Their use of this information-known as the memory for past-test (MPT) heuristic-is believed to be responsible for improvements in the relative accuracy (resolution) of people's JOLs across learning trials. Although participants seem to use past-test information as a major basis for their JOLs, little is known about how learners translate this information into a judgment of learning. Toward this end, in two experiments, we examined whether participants factored past-test performance into their JOLs in either an explicit, theory-based way or an implicit way. To do so, we had one group of participants (learners) study paired associates, make JOLs, and take a test on two study-test trials. Other participants (observers) viewed learners' protocols and made JOLs for the learners. Presumably, observers could only use theory-based information to make JOLs for the learners, which allowed us to estimate the contribution of explicit and implicit information to learners' JOLs. Our analyses suggest that all participants factored simple past-test performance into their JOLs in an explicit, theory-based way but that this information made limited contributions to improvements in relative accuracy across trials. In contrast, learners also used other privileged, implicit information about their learning to inform their judgments (that observers had no access to) that allowed them to achieve further improvements in relative accuracy across trials.

  11. The Mini-Balance Evaluation Systems Test (Mini-BESTest) Demonstrates Higher Accuracy in Identifying Older Adult Participants With History of Falls Than Do the BESTest, Berg Balance Scale, or Timed Up and Go Test.

    PubMed

    Yingyongyudha, Anyamanee; Saengsirisuwan, Vitoon; Panichaporn, Wanvisa; Boonsinsukh, Rumpa

    2016-01-01

    Balance deficits a significant predictor of falls in older adults. The Balance Evaluation Systems Test (BESTest) and the Mini-Balance Evaluation Systems Test (Mini-BESTest) are tools that may predict the likelihood of a fall, but their capabilities and accuracies have not been adequately addressed. Therefore, this study aimed at examining the capabilities of the BESTest and Mini-BESTest for identifying older adult with history of falls and comparing the participants with history of falls identification accuracy of the BESTest, Mini-BESTest, Berg Balance Scale (BBS), and the Timed Up and Go Test (TUG) for identifying participants with a history of falls. Two hundred healthy older adults with a mean age of 70 years were classified into participants with and without history of fall groups on the basis of their 12-month fall history. Their balance abilities were assessed using the BESTest, Mini-BESTest, BBS, and TUG. An analysis of the resulting receiver operating characteristic curves was performed to calculate the area under the curve (AUC), sensitivity, specificity, cutoff score, and posttest accuracy of each. The Mini-BESTest showed the highest AUC (0.84) compared with the BESTest (0.74), BBS (0.69), and TUG (0.35), suggesting that the Mini-BESTest had the highest accuracy in identifying older adult with history of falls. At the cutoff score of 16 (out of 28), the Mini-BESTest demonstrated a posttest accuracy of 85% with a sensitivity of 85% and specificity of 75%. The Mini-BESTest had the highest posttest accuracy, with the others having results of 76% (BESTest), 60% (BBS), and 65% (TUG). The Mini-BESTest is the most accurate tool for identifying older adult with history of falls compared with the BESTest, BBS, and TUG.

  12. Critical Variables in Singing Accuracy Test Construction: A Review of Literature

    ERIC Educational Resources Information Center

    Nichols, Bryan E.

    2016-01-01

    The purpose of this review of literature was to identify research findings for designing assessments in singing accuracy. The aim was to specify the test construction variables that directly affect test performance to guide future design in singing accuracy assessment for research and classroom uses. Three pitch-matching tasks--single pitch,…

  13. The role of individual differences in the accuracy of confidence judgments.

    PubMed

    Pallier, Gerry; Wilkinson, Rebecca; Danthiir, Vanessa; Kleitman, Sabina; Knezevic, Goran; Stankov, Lazar; Roberts, Richard D

    2002-07-01

    Generally, self-assessment of accuracy in the cognitive domain produces overconfidence, whereas self-assessment of visual perceptual judgments results in underconfidence. Despite contrary empirical evidence, in models attempting to explain those phenomena, individual differences have often been disregarded. The authors report on 2 studies in which that shortcoming was addressed. In Experiment 1, participants (N= 520) completed a large number of cognitive-ability tests. Results indicated that individual differences provide a meaningful source of overconfidence and that a metacognitive trait might mediate that effect. In further analysis, there was only a relatively small correlation between test accuracy and confidence bias. In Experiment 2 (N = 107 participants), both perceptual and cognitive ability tests were included, along with measures of personality. Results again indicated the presence of a confidence factor that transcended the nature of the testing vehicle. Furthermore, a small relationship was found between that factor and some self-reported personality measures. Thus, personality traits and cognitive ability appeared to play only a small role in determining the accuracy of self-assessment. Collectively, the present results suggest that there are multiple causes of miscalibration, which current models of over- and underconfidence fail to encompass.

  14. Sample size in studies on diagnostic accuracy in ophthalmology: a literature survey.

    PubMed

    Bochmann, Frank; Johnson, Zoe; Azuara-Blanco, Augusto

    2007-07-01

    To assess the sample sizes used in studies on diagnostic accuracy in ophthalmology. Design and sources: A survey literature published in 2005. The frequency of reporting calculations of sample sizes and the samples' sizes were extracted from the published literature. A manual search of five leading clinical journals in ophthalmology with the highest impact (Investigative Ophthalmology and Visual Science, Ophthalmology, Archives of Ophthalmology, American Journal of Ophthalmology and British Journal of Ophthalmology) was conducted by two independent investigators. A total of 1698 articles were identified, of which 40 studies were on diagnostic accuracy. One study reported that sample size was calculated before initiating the study. Another study reported consideration of sample size without calculation. The mean (SD) sample size of all diagnostic studies was 172.6 (218.9). The median prevalence of the target condition was 50.5%. Only a few studies consider sample size in their methods. Inadequate sample sizes in diagnostic accuracy studies may result in misleading estimates of test accuracy. An improvement over the current standards on the design and reporting of diagnostic studies is warranted.

  15. Accuracy of the Canadian C-spine rule and NEXUS to screen for clinically important cervical spine injury in patients following blunt trauma: a systematic review

    PubMed Central

    Michaleff, Zoe A.; Maher, Chris G.; Verhagen, Arianne P.; Rebbeck, Trudy; Lin, Chung-Wei Christine

    2012-01-01

    Background: There is uncertainty about the optimal approach to screen for clinically important cervical spine (C-spine) injury following blunt trauma. We conducted a systematic review to investigate the diagnostic accuracy of the Canadian C-spine rule and the National Emergency X-Radiography Utilization Study (NEXUS) criteria, 2 rules that are available to assist emergency physicians to assess the need for cervical spine imaging. Methods: We identified studies by an electronic search of CINAHL, Embase and MEDLINE. We included articles that reported on a cohort of patients who experienced blunt trauma and for whom clinically important cervical spine injury detectable by diagnostic imaging was the differential diagnosis; evaluated the diagnostic accuracy of the Canadian C-spine rule or NEXUS or both; and used an adequate reference standard. We assessed the methodologic quality using the Quality Assessment of Diagnostic Accuracy Studies criteria. We used the extracted data to calculate sensitivity, specificity, likelihood ratios and post-test probabilities. Results: We included 15 studies of modest methodologic quality. For the Canadian C-spine rule, sensitivity ranged from 0.90 to 1.00 and specificity ranged from 0.01 to 0.77. For NEXUS, sensitivity ranged from 0.83 to 1.00 and specificity ranged from 0.02 to 0.46. One study directly compared the accuracy of these 2 rules using the same cohort and found that the Canadian C-spine rule had better accuracy. For both rules, a negative test was more informative for reducing the probability of a clinically important cervical spine injury. Interpretation: Based on studies with modest methodologic quality and only one direct comparison, we found that the Canadian C-spine rule appears to have better diagnostic accuracy than the NEXUS criteria. Future studies need to follow rigorous methodologic procedures to ensure that the findings are as free of bias as possible. PMID:23048086

  16. Working Memory Components and Problem-Solving Accuracy: Are There Multiple Pathways?

    ERIC Educational Resources Information Center

    Swanson, H. Lee; Fung, Wenson

    2016-01-01

    This study determined the working memory (WM) components (executive, phonological short-term memory [STM], and visual-spatial sketchpad) that best predicted mathematical word problem-solving accuracy in elementary schoolchildren (N = 392). The battery of tests administered to assess mediators between WM and problem-solving included measures of…

  17. Conceptual Scoring and Classification Accuracy of Vocabulary Testing in Bilingual Children

    ERIC Educational Resources Information Center

    Anaya, Jissel B.; Peña, Elizabeth D.; Bedore, Lisa M.

    2018-01-01

    Purpose: This study examined the effects of single-language and conceptual scoring on the vocabulary performance of bilingual children with and without specific language impairment. We assessed classification accuracy across 3 scoring methods. Method: Participants included Spanish-English bilingual children (N = 247) aged 5;1 (years;months) to…

  18. Assessment of the diagnostic value of a urinary adipsin rapid strip test for pre-eclampsia: A prospective multicenter study.

    PubMed

    Peng, Bing; Zhang, Li; Yan, Jianying; Qi, Hongbo; Zhang, Weiyuan; Fan, Ling; Hu, Yayi; Lin, Li; Li, Xiaotian; Hu, Rong; Xie, Lan; Zhang, Jianping; Wu, Yanqiao; Li, Li; Zhou, Rong

    2017-01-01

    The purpose of the present study was to evaluate the clinical value of the rapid strip test of urinary adipsin for the quick diagnosis of pre-eclampsia. In a multicenter diagnostic test study, we studied the diagnostic accuracy of the rapid strip test of urinary adipsin in women presenting with pre-eclampsia. A total of 204 pre-eclampsia patients and 254 healthy pregnant women were recruited for this study, respectively. The rapid strip test of urinary adipsin was used to detect the adipsin in the urine of each patient. The diagnostic value of the rapid strip test of urinary adipsin for pre-eclampsia was demonstrated by its high sensitivity and specificity (95.10% and 97.64%, respectively). The diagnostic accuracy was 96.51%. The consistency analysis showed that the kappa value was 0.93 compared with the gold standard diagnosis of pre-eclampsia. The rapid strip test of urinary adipsin is a non-invasive test for the diagnosis of pre-eclampsia with high sensitivity and specificity. It could help the quick diagnosis of pre-eclampsia in clinical practice greatly. © 2016 Japan Society of Obstetrics and Gynecology.

  19. Time-series-based hybrid mathematical modelling method adapted to forecast automotive and medical waste generation: Case study of Lithuania.

    PubMed

    Karpušenkaitė, Aistė; Ruzgas, Tomas; Denafas, Gintaras

    2018-05-01

    The aim of the study was to create a hybrid forecasting method that could produce higher accuracy forecasts than previously used 'pure' time series methods. Mentioned methods were already tested with total automotive waste, hazardous automotive waste, and total medical waste generation, but demonstrated at least a 6% error rate in different cases and efforts were made to decrease it even more. Newly developed hybrid models used a random start generation method to incorporate different time-series advantages and it helped to increase the accuracy of forecasts by 3%-4% in hazardous automotive waste and total medical waste generation cases; the new model did not increase the accuracy of total automotive waste generation forecasts. Developed models' abilities to forecast short- and mid-term forecasts were tested using prediction horizon.

  20. Accuracy of the Timed Up and Go test for predicting sarcopenia in elderly hospitalized patients.

    PubMed

    Martinez, Bruno Prata; Gomes, Isabela Barboza; Oliveira, Carolina Santana de; Ramos, Isis Resende; Rocha, Mônica Diniz Marques; Forgiarini Júnior, Luiz Alberto; Camelier, Fernanda Warken Rosa; Camelier, Aquiles Assunção

    2015-05-01

    The ability of the Timed Up and Go test to predict sarcopenia has not been evaluated previously. The objective of this study was to evaluate the accuracy of the Timed Up and Go test for predicting sarcopenia in elderly hospitalized patients. This cross-sectional study analyzed 68 elderly patients (≥60 years of age) in a private hospital in the city of Salvador-BA, Brazil, between the 1st and 5th day of hospitalization. The predictive variable was the Timed Up and Go test score, and the outcome of interest was the presence of sarcopenia (reduced muscle mass associated with a reduction in handgrip strength and/or weak physical performance in a 6-m gait-speed test). After the descriptive data analyses, the sensitivity, specificity and accuracy of a test using the predictive variable to predict the presence of sarcopenia were calculated. In total, 68 elderly individuals, with a mean age 70.4±7.7 years, were evaluated. The subjects had a Charlson Comorbidity Index score of 5.35±1.97. Most (64.7%) of the subjects had a clinical admission profile; the main reasons for hospitalization were cardiovascular disorders (22.1%), pneumonia (19.1%) and abdominal disorders (10.2%). The frequency of sarcopenia in the sample was 22.1%, and the mean length of time spent performing the Timed Up and Go test was 10.02±5.38 s. A time longer than or equal to a cutoff of 10.85 s on the Timed Up and Go test predicted sarcopenia with a sensitivity of 67% and a specificity of 88.7%. The accuracy of this cutoff for the Timed Up and Go test was good (0.80; IC=0.66-0.94; p=0.002). The Timed Up and Go test was shown to be a predictor of sarcopenia in elderly hospitalized patients.

  1. Diagnostic validity of methods for assessment of swallowing sounds: a systematic review.

    PubMed

    Taveira, Karinna Veríssimo Meira; Santos, Rosane Sampaio; Leão, Bianca Lopes Cavalcante de; Neto, José Stechman; Pernambuco, Leandro; Silva, Letícia Korb da; De Luca Canto, Graziela; Porporatti, André Luís

    2018-02-03

    Oropharyngeal dysphagia is a highly prevalent comorbidity in neurological patients and presents a serious health threat, which may lead to outcomes of aspiration pneumonia, ranging from hospitalization to death. This assessment proposes a non-invasive, acoustic-based method to differentiate between individuals with and without signals of penetration and aspiration. This systematic review evaluated the diagnostic validity of different methods for assessment of swallowing sounds, when compared to Videofluroscopic of Swallowing Study (VFSS) to detect oropharyngeal dysphagia. Articles in which the primary objective was to evaluate the accuracy of swallowing sounds were searched in five electronic databases with no language or time limitations. Accuracy measurements described in the studies were transformed to construct receiver operating characteristic curves and forest plots with the aid of Review Manager v. 5.2 (The Nordic Cochrane Centre, Copenhagen, Denmark). The methodology of the selected studies was evaluated using the Quality Assessment Tool for Diagnostic Accuracy Studies-2. The final electronic search revealed 554 records, however only 3 studies met the inclusion criteria. The accuracy values (area under the curve) were 0.94 for microphone, 0.80 for Doppler, and 0.60 for stethoscope. Based on limited evidence and low methodological quality because few studies were included, with a small sample size, from all index testes found for this systematic review, Doppler showed excellent diagnostic accuracy for the discrimination of swallowing sounds, whereas microphone-reported good accuracy discrimination of swallowing sounds of dysphagic patients and stethoscope showed best screening test. Copyright © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  2. Assessment of the Thematic Accuracy of Land Cover Maps

    NASA Astrophysics Data System (ADS)

    Höhle, J.

    2015-08-01

    Several land cover maps are generated from aerial imagery and assessed by different approaches. The test site is an urban area in Europe for which six classes (`building', `hedge and bush', `grass', `road and parking lot', `tree', `wall and car port') had to be derived. Two classification methods were applied (`Decision Tree' and `Support Vector Machine') using only two attributes (height above ground and normalized difference vegetation index) which both are derived from the images. The assessment of the thematic accuracy applied a stratified design and was based on accuracy measures such as user's and producer's accuracy, and kappa coefficient. In addition, confidence intervals were computed for several accuracy measures. The achieved accuracies and confidence intervals are thoroughly analysed and recommendations are derived from the gained experiences. Reliable reference values are obtained using stereovision, false-colour image pairs, and positioning to the checkpoints with 3D coordinates. The influence of the training areas on the results is studied. Cross validation has been tested with a few reference points in order to derive approximate accuracy measures. The two classification methods perform equally for five classes. Trees are classified with a much better accuracy and a smaller confidence interval by means of the decision tree method. Buildings are classified by both methods with an accuracy of 99% (95% CI: 95%-100%) using independent 3D checkpoints. The average width of the confidence interval of six classes was 14% of the user's accuracy.

  3. Analysis article: accuracy of the DIDGET glucose meter in children and young adults with diabetes.

    PubMed

    Kim, Sarah

    2011-09-01

    Diabetes is one of the most common chronic diseases among American children. Although studies show that intensive management, including frequent glucose testing, improves diabetes control, this is difficult to accomplish. Bayer's DIDGET® glucose meter system pairs with a popular handheld video game system and couples good blood glucose testing habits with video-game-based rewards. In this issue, Deeb and colleagues performed a study demonstrating the accuracy of the DIDGET meter, a critical asset to this novel product designed to alleviate some of the challenges of managing pediatric diabetes. © 2011 Diabetes Technology Society.

  4. Accuracy of electronic implant torque controllers following time in clinical service.

    PubMed

    Mitrani, R; Nicholls, J I; Phillips, K M; Ma, T

    2001-01-01

    Tightening of the screws in implant-supported restorations has been reported to be problematic, in that if the applied torque is too low, screw loosening occurs. If the torque is too high, then screw fracture can take place. Thus, accuracy of the torque driver is of the utmost importance. This study evaluated 4 new electronic torque drivers (controls) and 10 test electronic torque drivers, which had been in clinical service for a minimum of 5 years. Torque values of the test drivers were measured and were compared with the control values using a 1-way analysis of variance. Torque delivery accuracy was measured using a technique that simulated the clinical situation. In vivo, the torque driver turns the screw until the selected tightening torque is reached. In this laboratory experiment, an implant, along with an attached abutment and abutment gold screw, was held firmly in a Tohnichi torque gauge. Calibration accuracy for the Tohnichi is +/- 3% of the scale value. During torque measurement, the gold screw turned a minimum of 180 degrees before contact was made between the screw and abutment. Three torque values (10, 20, and 32 N-cm) were evaluated, at both high- and low-speed settings. The recorded torque measurements indicated that the 10 test electronic torque drivers maintained a torque delivery accuracy equivalent to the 4 new (unused) units. Judging from the torque output values obtained from the 10 test units, the clinical use of the electronic torque driver suggests that accuracy did not change significantly over the 5-year period of clinical service.

  5. Cytology versus HPV testing for cervical cancer screening in the general population.

    PubMed

    Koliopoulos, George; Nyaga, Victoria N; Santesso, Nancy; Bryant, Andrew; Martin-Hirsch, Pierre Pl; Mustafa, Reem A; Schünemann, Holger; Paraskevaidis, Evangelos; Arbyn, Marc

    2017-08-10

    Cervical cancer screening has traditionally been based on cervical cytology. Given the aetiological relationship between human papillomavirus (HPV) infection and cervical carcinogenesis, HPV testing has been proposed as an alternative screening test. To determine the diagnostic accuracy of HPV testing for detecting histologically confirmed cervical intraepithelial neoplasias (CIN) of grade 2 or worse (CIN 2+), including adenocarcinoma in situ, in women participating in primary cervical cancer screening; and how it compares to the accuracy of cytological testing (liquid-based and conventional) at various thresholds. We performed a systematic literature search of articles in MEDLINE and Embase (1992 to November 2015) containing quantitative data and handsearched the reference lists of retrieved articles. We included comparative test accuracy studies if all women received both HPV testing and cervical cytology followed by verification of the disease status with the reference standard, if positive for at least one screening test. The studies had to include women participating in a cervical cancer screening programme who were not being followed up for previous cytological abnormalities. We completed a 2 x 2 table with the number of true positives (TP), false positives (FP), true negatives (TN), and false negatives for each screening test (HPV test and cytology) used in each study. We calculated the absolute and relative sensitivities and the specificities of the tests for the detection of CIN 2+ and CIN 3+ at various thresholds and computed sensitivity (TP/(TP + TN) and specificity (TN/ (TN + FP) for each test separately. Relative sensitivity and specificity of one test compared to another test were defined as sensitivity of test-1 over sensitivity of test-2 and specificity of test-1 over specificity of test-2, respectively. To assess bias in the studies, we used the Quality Assessment of Diagnostic test Accuracy Studies (QUADAS) tool. We used a bivariate random-effects model for computing pooled accuracy estimates. This model takes into account the within- and between-study variability and the intrinsic correlation between sensitivity and specificity. We included a total of 40 studies in the review, with more than 140,000 women aged between 20 and 70 years old. Many studies were at low risk of bias. There were a sufficient number of included studies with adequate methodology to perform the following test comparisons: hybrid capture 2 (HC2) (1 pg/mL threshold) versus conventional cytology (CC) (atypical squamous cells of undetermined significance (ASCUS)+ and low-grade squamous intraepithelial lesions (LSIL)+ thresholds) or liquid-based cytology (LBC) (ASCUS+ and LSIL+ thresholds), other high-risk HPV tests versus conventional cytology (ASCUS+ and LSIL+ thresholds) or LBC (ASCUS+ and LSIL+ thresholds). For CIN 2+, pooled sensitivity estimates for HC2, CC and LBC (ASCUS+) were 89.9%, 62.5% and 72.9%, respectively, and pooled specificity estimates were 89.9%, 96.6%, and 90.3%, respectively. The results did not differ by age of women (less than or greater than 30 years old), or in studies with verification bias. Accuracy of HC2 was, however, greater in European countries compared to other countries. The results for the sensitivity of the tests were heterogeneous ranging from 52% to 94% for LBC, and 61% to 100% for HC2. Overall, the quality of the evidence for the sensitivity of the tests was moderate, and high for the specificity.The relative sensitivity of HC2 versus CC for CIN 2+ was 1.52 (95% CI: 1.24 to 1.86) and the relative specificity 0.94 (95% CI: 0.92 to 0.96), and versus LBC for CIN 2+ was 1.18 (95% CI: 1.10 to 1.26) and the relative specificity 0.96 (95% CI: 0.95 to 0.97). The relative sensitivity of HC2 versus CC for CIN 3+ was 1.46 (95% CI: 1.12 to 1.91) and the relative specificity 0.95 (95% CI: 0.93 to 0.97). The relative sensitivity of HC2 versus LBC for CIN 3+ was 1.17 (95% CI: 1.07 to 1.28) and the relative specificity 0.96 (95% CI: 0.95 to 0.97). Whilst HPV tests are less likely to miss cases of CIN 2+ and CIN 3+, these tests do lead to more unnecessary referrals. However, a negative HPV test is more reassuring than a negative cytological test, as the cytological test has a greater chance of being falsely negative, which could lead to delays in receiving the appropriate treatment. Evidence from prospective longitudinal studies is needed to establish the relative clinical implications of these tests.

  6. Testing Accuracy of Long-Range Ultrasonic Sensors for Olive Tree Canopy Measurements

    PubMed Central

    Gamarra-Diezma, Juan Luis; Miranda-Fuentes, Antonio; Llorens, Jordi; Cuenca, Andrés; Blanco-Roldán, Gregorio L.; Rodríguez-Lizana, Antonio

    2015-01-01

    Ultrasonic sensors are often used to adjust spray volume by allowing the calculation of the crown volume of tree crops. The special conditions of the olive tree require the use of long-range sensors, which are less accurate and faster than the most commonly used sensors. The main objectives of the study were to determine the suitability of the sensor in terms of sound cone determination, angle errors, crosstalk errors and field measurements. Different laboratory tests were performed to check the suitability of a commercial long-range ultrasonic sensor, as were the experimental determination of the sound cone diameter at several distances for several target materials, the determination of the influence of the angle of incidence of the sound wave on the target and distance on the accuracy of measurements for several materials and the determination of the importance of the errors due to interference between sensors for different sensor spacings and distances for two different materials. Furthermore, sensor accuracy was tested under real field conditions. The results show that the studied sensor is appropriate for olive trees because the sound cone is narrower for an olive tree than for the other studied materials, the olive tree canopy does not have a large influence on the sensor accuracy with respect to distance and angle, the interference errors are insignificant for high sensor spacings and the sensor's field distance measurements were deemed sufficiently accurate. PMID:25635414

  7. The accuracy of the glucagon test compared to the insulin tolerance test in the diagnosis of adrenal insufficiency in young children with growth hormone deficiency.

    PubMed

    di Iorgi, Natascia; Napoli, Flavia; Allegri, Anna; Secco, Andrea; Calandra, Erika; Calcagno, AnnaLisa; Frassinetti, Costanza; Ghezzi, Michele; Ambrosini, Linda; Parodi, Stefano; Gastaldi, Roberto; Loche, Sandro; Maghnie, Mohamad

    2010-05-01

    The accuracy of the glucagon test in the diagnosis of central adrenal insufficiency in young children has not yet been definitively established. The aim of this study was to investigate the diagnostic accuracy of the glucagon test as an alternative to the insulin tolerance test (ITT) in children with GH deficiency under 6 yr of age. This was a prospective study conducted in two Pediatric Endocrinology Centers. Forty-eight children (median age, 4.2 yr) with GH deficiency confirmed by a peak GH to ITT and arginine less than 10 microg/liter were enrolled: 24 with normal hypothalamic-pituitary anatomy, seven with isolated anterior pituitary hypoplasia, and 17 with structural hypothalamic-pituitary abnormalities at magnetic resonance imaging. Twelve subjects had central adrenal insufficiency defined by a peak cortisol response of less than 20 microg/dl to ITT. All children underwent a glucagon stimulation test with blood sampling for cortisol and glucose (time 0 to 180 min) after the im administration of 30 microg/kg of glucagon. The mean peak cortisol after glucagon was not significantly different from that obtained after ITT in the whole cohort (25.9 vs. 26.0 microg/dl; P = 0.908), and it was significantly reduced in patients with structural hypothalamic-pituitary abnormalities (P < 0.001). Receiver operating characteristic curve analysis showed that the best diagnostic accuracy was obtained with a peak cortisol cutoff to glucagon of 14.6 microg/dl (sensitivity, 66.67%; specificity, 100%; area under the curve = 0.91; 95% confidence interval, 0.82-0.99). Using this cutoff, 91.67% of the patients were correctly classified. This study shows that glucagon is an accurate and safe diagnostic test for adrenal function in young children who are at risk for adrenal insufficiency.

  8. Testing the accuracy of timing reports in visual timing tasks with a consumer-grade digital camera.

    PubMed

    Smyth, Rachael E; Oram Cardy, Janis; Purcell, David

    2017-06-01

    This study tested the accuracy of a visual timing task using a readily available and relatively inexpensive consumer grade digital camera. A visual inspection time task was recorded using short high-speed video clips and the timing as reported by the task's program was compared to the timing as recorded in the video clips. Discrepancies in these two timing reports were investigated further and based on display refresh rate, a decision was made whether the discrepancy was large enough to affect the results as reported by the task. In this particular study, the errors in timing were not large enough to impact the results of the study. The procedure presented in this article offers an alternative method for performing a timing test, which uses readily available hardware and can be used to test the timing in any software program on any operating system and display.

  9. Refining Ovarian Cancer Test accuracy Scores (ROCkeTS): protocol for a prospective longitudinal test accuracy study to validate new risk scores in women with symptoms of suspected ovarian cancer.

    PubMed

    Sundar, Sudha; Rick, Caroline; Dowling, Francis; Au, Pui; Snell, Kym; Rai, Nirmala; Champaneria, Rita; Stobart, Hilary; Neal, Richard; Davenport, Clare; Mallett, Susan; Sutton, Andrew; Kehoe, Sean; Timmerman, Dirk; Bourne, Tom; Van Calster, Ben; Gentry-Maharaj, Aleksandra; Menon, Usha; Deeks, Jon

    2016-08-09

    Ovarian cancer (OC) is associated with non-specific symptoms such as bloating, making accurate diagnosis challenging: only 1 in 3 women with OC presents through primary care referral. National Institute for Health and Care Excellence guidelines recommends sequential testing with CA125 and routine ultrasound in primary care. However, these diagnostic tests have limited sensitivity or specificity. Improving accurate triage in women with vague symptoms is likely to improve mortality by streamlining referral and care pathways. The Refining Ovarian Cancer Test Accuracy Scores (ROCkeTS; HTA 13/13/01) project will derive and validate new tests/risk prediction models that estimate the probability of having OC in women with symptoms. This protocol refers to the prospective study only (phase III). ROCkeTS comprises four parallel phases. The full ROCkeTS protocol can be found at http://www.birmingham.ac.uk/ROCKETS. Phase III is a prospective test accuracy study. The study will recruit 2450 patients from 15 UK sites. Recruited patients complete symptom and anxiety questionnaires, donate a serum sample and undergo ultrasound scored as per International Ovarian Tumour Analysis (IOTA) criteria. Recruitment is at rapid access clinics, emergency departments and elective clinics. Models to be evaluated include those based on ultrasound derived by the IOTA group and novel models derived from analysis of existing data sets. Estimates of sensitivity, specificity, c-statistic (area under receiver operating curve), positive predictive value and negative predictive value of diagnostic tests are evaluated and a calibration plot for models will be presented. ROCkeTS has received ethical approval from the NHS West Midlands REC (14/WM/1241) and is registered on the controlled trials website (ISRCTN17160843) and the National Institute of Health Research Cancer and Reproductive Health portfolios. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  10. Diagnostic accuracy of fractional exhaled nitric oxide measurement in predicting cough-variant asthma and eosinophilic bronchitis in adults with chronic cough: A systematic review and meta-analysis.

    PubMed

    Song, Woo-Jung; Kim, Hyun Jung; Shim, Ji-Su; Won, Ha-Kyeong; Kang, Sung-Yoon; Sohn, Kyoung-Hee; Kim, Byung-Keun; Jo, Eun-Jung; Kim, Min-Hye; Kim, Sang-Heon; Park, Heung-Woo; Kim, Sun-Sin; Chang, Yoon-Seok; Morice, Alyn H; Lee, Byung-Jae; Cho, Sang-Heon

    2017-09-01

    Individual studies have suggested the utility of fractional exhaled nitric oxide (Feno) measurement in detecting cough-variant asthma (CVA) and eosinophilic bronchitis (EB) in patients with chronic cough. We sought to obtain summary estimates of diagnostic test accuracy of Feno measurement in predicting CVA, EB, or both in adults with chronic cough. Electronic databases were searched for studies published until January 2016, without language restriction. Cross-sectional studies that reported the diagnostic accuracy of Feno measurement for detecting CVA or EB were included. Risk of bias was assessed with Quality Assessment of Diagnostic Accuracy Studies 2. Random effects meta-analyses were performed to obtain summary estimates of the diagnostic accuracy of Feno measurement. A total of 15 studies involving 2187 adults with chronic cough were identified. Feno measurement had a moderate diagnostic accuracy in predicting CVA in patients with chronic cough, showing the summary area under the curve to be 0.87 (95% CI, 0.83-0.89). Specificity was higher and more consistent than sensitivity (0.85 [95% CI, 0.81-0.88] and 0.72 [95% CI, 0.61-0.81], respectively). However, in the nonasthmatic population with chronic cough, the diagnostic accuracy to predict EB was found to be relatively lower (summary area under the curve, 0.81 [95% CI, 0.77-0.84]), and specificity was inconsistent. The present meta-analyses indicated the diagnostic potential of Feno measurement as a rule-in test for detecting CVA in adult patients with chronic cough. However, Feno measurement may not be useful to predict EB in nonasthmatic subjects with chronic cough. These findings warrant further studies to validate the roles of Feno measurement in clinical practice of patients with chronic cough. Copyright © 2017 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  11. Ultrasound versus liver function tests for diagnosis of common bile duct stones.

    PubMed

    Gurusamy, Kurinchi Selvan; Giljaca, Vanja; Takwoingi, Yemisi; Higgie, David; Poropat, Goran; Štimac, Davor; Davidson, Brian R

    2015-02-26

    Ultrasound and liver function tests (serum bilirubin and serum alkaline phosphatase) are used as screening tests for the diagnosis of common bile duct stones in people suspected of having common bile duct stones. There has been no systematic review of the diagnostic accuracy of ultrasound and liver function tests. To determine and compare the accuracy of ultrasound versus liver function tests for the diagnosis of common bile duct stones. We searched MEDLINE, EMBASE, Science Citation Index Expanded, BIOSIS, and Clinicaltrials.gov to September 2012. We searched the references of included studies to identify further studies and systematic reviews identified from various databases (Database of Abstracts of Reviews of Effects, Health Technology Assessment, Medion, and ARIF (Aggressive Research Intelligence Facility)). We did not restrict studies based on language or publication status, or whether data were collected prospectively or retrospectively. We included studies that provided the number of true positives, false positives, false negatives, and true negatives for ultrasound, serum bilirubin, or serum alkaline phosphatase. We only accepted studies that confirmed the presence of common bile duct stones by extraction of the stones (irrespective of whether this was done by surgical or endoscopic methods) for a positive test result, and absence of common bile duct stones by surgical or endoscopic negative exploration of the common bile duct, or symptom-free follow-up for at least six months for a negative test result as the reference standard in people suspected of having common bile duct stones. We included participants with or without prior diagnosis of cholelithiasis; with or without symptoms and complications of common bile duct stones, with or without prior treatment for common bile duct stones; and before or after cholecystectomy. At least two authors screened abstracts and selected studies for inclusion independently. Two authors independently collected data from each study. Where meta-analysis was possible, we used the bivariate model to summarise sensitivity and specificity. Five studies including 523 participants reported the diagnostic accuracy of ultrasound. One studies (262 participants) compared the accuracy of ultrasound, serum bilirubin and serum alkaline phosphatase in the same participants. All the studies included people with symptoms. One study included only participants without previous cholecystectomy but this information was not available from the remaining studies. All the studies were of poor methodological quality. The sensitivities for ultrasound ranged from 0.32 to 1.00, and the specificities ranged from 0.77 to 0.97. The summary sensitivity was 0.73 (95% CI 0.44 to 0.90) and the specificity was 0.91 (95% CI 0.84 to 0.95). At the median pre-test probability of common bile duct stones of 0.408, the post-test probability (95% CI) associated with positive ultrasound tests was 0.85 (95% CI 0.75 to 0.91), and negative ultrasound tests was 0.17 (95% CI 0.08 to 0.33).The single study of liver function tests reported diagnostic accuracy at two cut-offs for bilirubin (greater than 22.23 μmol/L and greater than twice the normal limit) and two cut-offs for alkaline phosphatase (greater than 125 IU/L and greater than twice the normal limit). This study also assessed ultrasound and reported higher sensitivities for bilirubin and alkaline phosphatase at both cut-offs but the specificities of the markers were higher at only the greater than twice the normal limit cut-off. The sensitivity for ultrasound was 0.32 (95% CI 0.15 to 0.54), bilirubin (cut-off greater than 22.23 μmol/L) was 0.84 (95% CI 0.64 to 0.95), and alkaline phosphatase (cut-off greater than 125 IU/L) was 0.92 (95% CI 0.74 to 0.99). The specificity for ultrasound was 0.95 (95% CI 0.91 to 0.97), bilirubin (cut-off greater than 22.23 μmol/L) was 0.91 (95% CI 0.86 to 0.94), and alkaline phosphatase (cut-off greater than 125 IU/L) was 0.79 (95% CI 0.74 to 0.84). No study reported the diagnostic accuracy of a combination of bilirubin and alkaline phosphatase, or combinations with ultrasound. Many people may have common bile duct stones in spite of having a negative ultrasound or liver function test. Such people may have to be re-tested with other modalities if the clinical suspicion of common bile duct stones is very high because of their symptoms. False-positive results are also possible and further non-invasive testing is recommended to confirm common bile duct stones to avoid the risks of invasive testing.It should be noted that these results were based on few studies of poor methodological quality and the results for ultrasound varied considerably between studies. Therefore, the results should be interpreted with caution. Further studies of high methodological quality are necessary to determine the diagnostic accuracy of ultrasound and liver function tests.

  12. The verification of LANDSAT data in the geographical analysis of wetlands in west Tennessee

    NASA Technical Reports Server (NTRS)

    Rehder, J.; Quattrochi, D. A.

    1978-01-01

    The reliability of LANDSAT imagery as a medium for identifying, delimiting, monitoring, measuring, and mapping wetlands in west Tennessee was assessed to verify LANDSAT as an accurate, efficient cartographic tool that could be employed by a wide range of users to study wetland dynamics. The verification procedure was based on the visual interpretation and measurement of multispectral imagery. The accuracy testing procedure was predicated on surrogate ground truth data gleaned from medium altitude imagery of the wetlands. Fourteen sites or case study areas were selected from individual 9 x 9 inch photo frames on the aerial photography. These sites were then used as data control calibration parameters for assessing the cartography accuracy of the LANDSAT imagery. An analysis of results obtained from the verification tests indicated that 1:250,000 scale LANDSAT data were the most reliable scale of imagery for visually mapping and measuring wetlands using the area grid technique. The mean areal percentage of accuracy was 93.54 percent (real) and 96.93 percent (absolute). As a test of accuracy, the LANDSAT 1:250,000 scale overall wetland measurements were compared with an area cell mensuration of the swamplands from 1:130,000 scale color infrared U-2 aircraft imagery. The comparative totals substantiated the results from the LANDSAT verification procedure.

  13. Social power facilitates the effect of prosocial orientation on empathic accuracy.

    PubMed

    Côté, Stéphane; Kraus, Michael W; Cheng, Bonnie Hayden; Oveis, Christopher; van der Löwe, Ilmo; Lian, Hua; Keltner, Dacher

    2011-08-01

    Power increases the tendency to behave in a goal-congruent fashion. Guided by this theoretical notion, we hypothesized that elevated power would strengthen the positive association between prosocial orientation and empathic accuracy. In 3 studies with university and adult samples, prosocial orientation was more strongly associated with empathic accuracy when distinct forms of power were high than when power was low. In Study 1, a physiological indicator of prosocial orientation, respiratory sinus arrhythmia, exhibited a stronger positive association with empathic accuracy in a face-to-face interaction among dispositionally high-power individuals. In Study 2, experimentally induced prosocial orientation increased the ability to accurately judge the emotions of a stranger but only for individuals induced to feel powerful. In Study 3, a trait measure of prosocial orientation was more strongly related to scores on a standard test of empathic accuracy among employees who occupied high-power positions within an organization. Study 3 further showed a mediated relationship between prosocial orientation and career satisfaction through empathic accuracy among employees in high-power positions but not among employees in lower power positions. Discussion concentrates upon the implications of these findings for studies of prosociality, power, and social behavior.

  14. Lack of Accuracy of Body Temperature for Detecting Serious Bacterial Infection in Febrile Episodes.

    PubMed

    De, Sukanya; Williams, Gabrielle J; Teixeira-Pinto, Armando; Macaskill, Petra; McCaskill, Mary; Isaacs, David; Craig, Jonathan C

    2015-09-01

    Body temperature is a time-honored marker of serious bacterial infection, but there are few studies of its test performance. The aim of our study was to determine the accuracy of temperature measured on presentation to medical care for detecting serious bacterial infection. Febrile children 0-5 years of age presenting to the emergency department of a tertiary care pediatric hospital were sampled consecutively. The accuracy of the axillary temperature measured at presentation was evaluated using logistic regression models to generate receiver operating characteristic curves. Reference standard tests for serious bacterial infection were standard microbiologic/radiologic tests and clinical follow-up. Age, clinicians' impression of appearance of the child (well versus unwell) and duration of illness were assessed as possible effect modifiers. Of 15,781 illness episodes 1120 (7.1%) had serious bacterial infection. The area under the receiver operating characteristic curve for temperature was 0.60 [95% confidence intervals (CI): 0.58-0.62]. A threshold of ≥ 38°C had a sensitivity of 0.67 (95% CI: 0.64-0.70), specificity of 0.45 (95% CI: 0.44-0.46), positive likelihood ratio of 1.2 (95% CI: 1.2-1.3) and negative likelihood ratio of 0.7 (95% CI: 0.7-0.8). Age and illness duration had a small but significant effect on the accuracy of temperature increasing its "rule-in" potential. Measured temperature at presentation to hospital is not an accurate marker of serious bacterial infection in febrile children. Younger age and longer duration of illness increase the rule-in potential of temperature but without substantial overall change in its test accuracy.

  15. A discussion of current issues and concepts in the practice of skull-photo/craniofacial superimposition.

    PubMed

    Gordon, G M; Steyn, M

    2016-05-01

    A recent review paper on cranio-facial superimposition (CFS) stated that "there have been specific conceptual variances" from the original methods used in the practice of skull-photo superimposition, leading to poor results as far as accuracy is concerned. It was argued that the deviations in the practice of the technique have resulted in the reduced accuracies (for both failure to include and failure to exclude) that are noted in several recent studies. This paper aims to present the results from recent research to highlight the advancement of skull-photo/cranio-facial superimposition, and to discuss some of the issues raised regarding deviations from original techniques. The evolving methodology of CFS is clarified in context with the advancement of technology, forensic science and specifically within the field of forensic anthropology. Developments in the skull-photo/cranio-facial superimposition techniques have largely focused on testing reliability and accuracy objectively. Techniques now being employed by forensic anthropologists must conform to rigorous scientific testing and methodologies. Skull-photo/cranio-facial superimposition is constantly undergoing accuracy and repeatability testing which is in line with the principles of the scientific method and additionally allows for advancement in the field. Much of the research has indicated that CFS is useful in exclusion which is consistent with the concept of Popperian falsifiability - a hypothesis and experimental design which is falsifiable. As the hypothesis is disproved or falsified, another evolves to replace it and explain the new observations. Current and future studies employing different methods to test the accuracy and reliability of skull-photo/cranio-facial superimposition will enable researchers to establish the contribution the technique can have for identification purposes. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  16. The Effect of Pixel Size on the Accuracy of Orthophoto Production

    NASA Astrophysics Data System (ADS)

    Kulur, S.; Yildiz, F.; Selcuk, O.; Yildiz, M. A.

    2016-06-01

    In our country, orthophoto products are used by the public and private sectors for engineering services and infrastructure projects, Orthophotos are particularly preferred due to faster and are more economical production according to vector digital photogrammetric production. Today, digital orthophotos provide an expected accuracy for engineering and infrastructure projects. In this study, the accuracy of orthophotos using pixel sizes with different sampling intervals are tested for the expectations of engineering and infrastructure projects.

  17. Diagnostic Accuracy of Memory Measures in Alzheimer’s Dementia and Mild Cognitive Impairment: a Systematic Review and Meta-Analysis

    PubMed Central

    Weissberger, Gali H.; Strong, Jessica V.; Stefanidis, Kayla B.; Summers, Mathew J.; Bondi, Mark W.; Stricker, Nikki H.

    2018-01-01

    With an increasing focus on biomarkers in dementia research, illustrating the role of neuropsychological assessment in detecting mild cognitive impairment (MCI) and Alzheimer’s dementia (AD) is important. This systematic review and meta-analysis, conducted in accordance with PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses) standards, summarizes the sensitivity and specificity of memory measures in individuals with MCI and AD. Both meta-analytic and qualitative examination of AD versus healthy control (HC) studies (n = 47) revealed generally high sensitivity and specificity (≥ 80% for AD comparisons) for measures of immediate (sensitivity = 87%, specificity = 88%) and delayed memory (sensitivity = 89%, specificity = 89%), especially those involving word-list recall. Examination of MCI versus HC studies (n = 38) revealed generally lower diagnostic accuracy for both immediate (sensitivity = 72%, specificity = 81%) and delayed memory (sensitivity = 75%, specificity = 81%). Measures that differentiated AD from other conditions (n = 10 studies) yielded mixed results, with generally high sensitivity in the context of low or variable specificity. Results confirm that memory measures have high diagnostic accuracy for identification of AD, are promising but require further refinement for identification of MCI, and provide support for ongoing investigation of neuropsychological assessment as a cognitive biomarker of preclinical AD. Emphasizing diagnostic test accuracy statistics over null hypothesis testing in future studies will promote the ongoing use of neuropsychological tests as Alzheimer’s disease research and clinical criteria increasingly rely upon cerebrospinal fluid (CSF) and neuroimaging biomarkers. PMID:28940127

  18. Evaluation of Raman spectroscopy in comparison to commonly performed dengue diagnostic tests

    NASA Astrophysics Data System (ADS)

    Khan, Saranjam; Ullah, Rahat; Khurram, Muhammad; Ali, Hina; Mahmood, Arshad; Khan, Ajmal; Ahmed, Mushtaq

    2016-09-01

    This study demonstrates the evaluation of Raman spectroscopy as a rapid diagnostic test in comparison to commonly performed tests for an accurate detection of dengue fever in human blood sera. Blood samples of 104 suspected dengue patients collected from Holy Family Hospital, Rawalpindi, Pakistan, have been used in this study. Out of 104 samples, 52 (50%) were positive based on immunoglobulin G (IgG), whereas 54 (52%) were positive based on immunoglobulin M (IgM) antibody tests. For the determination of the diagnostic capabilities of Raman spectroscopy, accuracy, sensitivity, specificity and false positive rate have been calculated in comparison to normally performed IgM and IgG captured enzyme-linked immunosorbent assay tests. Accuracy, precision, specificity, and sensitivity for Raman spectroscopy in comparison to IgM were found to be 66%, 70%, 72%, and 61%, whereas based on IgG they were 47%, 46%, 52%, and 43%, respectively.

  19. Neutral mood induction during reconsolidation reduces accuracy, but not vividness and anxiety of emotional episodic memories.

    PubMed

    Liu, Guanyu; McNally, Richard J

    2017-03-01

    Consolidated memories become labile upon reactivation and as a result have to go through reconsolidation to become re-stabilized. This property of memory may potentially be used to reduce the impact of highly negative episodic memories. Because detailed and vivid negative memories are mediated by high arousal, if arousal is lessened during reconsolidation, memory accuracy and vividness should diminish. In this study, we examined this hypothesis. Participants (N = 72) viewed a stressful, suspenseful video on Day 1 to develop negative episodic memories. Then, 24-29 h later, they saw a brief reminder of the stressful video (or not), and then viewed a neutral, calming (or positive) video. Another 24-29 h later, participants were tested on the accuracy, vividness, and anxiety associated with their memory of the stressful video on Day 1. Participants who watched the reminder and then the neutral video showed reduced memory accuracy compared to participants in the other groups. Despite the reduction in memory accuracy, their memory vividness and anxiety associated with the stressful video did not decrease. The use of undergraduates prevents generalizations to clinical populations. Also, the study did not test long-term memories that were more than 2 days old. Neutral mood induction during reconsolidation reduces the accuracy of highly negative episodic memories. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Clinical evaluation of the FreeStyle Precision Pro system.

    PubMed

    Brazg, Ronald; Hughes, Kristen; Martin, Pamela; Coard, Julie; Toffaletti, John; McDonnell, Elizabeth; Taylor, Elizabeth; Farrell, Lausanne; Patel, Mona; Ward, Jeanne; Chen, Ting; Alva, Shridhara; Ng, Ronald

    2013-06-05

    A new version of international standard (ISO 15197) and CLSI Guideline (POCT12) with more stringent accuracy criteria are near publication. We evaluated the glucose test performance of the FreeStyle Precision Pro system, a new blood glucose monitoring system (BGMS) designed to enhance accuracy for point-of-care testing (POCT). Precision, interference and system accuracy with 503 blood samples from capillary, venous and arterial sources were evaluated in a multicenter study. Study results were analyzed and presented in accordance with the specifications and recommendations of the final draft ISO 15197 and the new POCT12. The FreeStyle Precision Pro system demonstrated acceptable precision (CV <5%), no interference across a hematocrit range of 15-65%, and, except for xylose, no interference from 24 of 25 potentially interfering substances. It also met all accuracy criteria specified in the final draft ISO 15197 and POCT12, with 97.3-98.9% of the individual results of various blood sample types agreeing within ±12 mg/dl of the laboratory analyzer values at glucose concentrations <100mg/dl and within ±12.5% of the laboratory analyzer values at glucose concentrations ≥100 mg/dl. The FreeStyle Precision Pro system met the tighter accuracy requirements, providing a means for enhancing accuracy for point-of-care blood glucose monitoring. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. The use of video in standardized patient training to improve portrayal accuracy: A randomized post-test control group study.

    PubMed

    Schlegel, Claudia; Bonvin, Raphael; Rethans, Jan Joost; van der Vleuten, Cees

    2014-10-14

    Abstract Introduction: High-stake objective structured clinical examinations (OSCEs) with standardized patients (SPs) should offer the same conditions to all candidates throughout the exam. SP performance should therefore be as close to the original role script as possible during all encounters. In this study, we examined the impact of video in SP training on SPs' role accuracy, investigating how the use of different types of video during SP training improves the accuracy of SP portrayal. Methods: In a randomized post-test, control group design three groups of 12 SPs each with different types of video training and one control group of 12 SPs without video use in SP training were compared. The three intervention groups used role-modeling video, performance-feedback video, or a combination of both. Each SP from each group had four students encounter. Two blinded faculty members rated the 192 video-recorded encounters, using a case-specific rating instrument to assess SPs' role accuracy. Results: SPs trained by video showed significantly (p < 0.001) better role accuracy than SPs trained without video over the four sequential portrayals. There was no difference between the three types of video training. Discussion: Use of video during SP training enhances the accuracy of SP portrayal compared with no video, regardless of the type of video intervention used.

  2. Diagnostic accuracy of a bayesian latent group analysis for the detection of malingering-related poor effort.

    PubMed

    Ortega, Alonso; Labrenz, Stephan; Markowitsch, Hans J; Piefke, Martina

    2013-01-01

    In the last decade, different statistical techniques have been introduced to improve assessment of malingering-related poor effort. In this context, we have recently shown preliminary evidence that a Bayesian latent group model may help to optimize classification accuracy using a simulation research design. In the present study, we conducted two analyses. Firstly, we evaluated how accurately this Bayesian approach can distinguish between participants answering in an honest way (honest response group) and participants feigning cognitive impairment (experimental malingering group). Secondly, we tested the accuracy of our model in the differentiation between patients who had real cognitive deficits (cognitively impaired group) and participants who belonged to the experimental malingering group. All Bayesian analyses were conducted using the raw scores of a visual recognition forced-choice task (2AFC), the Test of Memory Malingering (TOMM, Trial 2), and the Word Memory Test (WMT, primary effort subtests). The first analysis showed 100% accuracy for the Bayesian model in distinguishing participants of both groups with all effort measures. The second analysis showed outstanding overall accuracy of the Bayesian model when estimates were obtained from the 2AFC and the TOMM raw scores. Diagnostic accuracy of the Bayesian model diminished when using the WMT total raw scores. Despite, overall diagnostic accuracy can still be considered excellent. The most plausible explanation for this decrement is the low performance in verbal recognition and fluency tasks of some patients of the cognitively impaired group. Additionally, the Bayesian model provides individual estimates, p(zi |D), of examinees' effort levels. In conclusion, both high classification accuracy levels and Bayesian individual estimates of effort may be very useful for clinicians when assessing for effort in medico-legal settings.

  3. Comparison of the accuracy of Hybrid Capture II and polymerase chain reaction in detecting clinically important cervical dysplasia: a systematic review and meta-analysis

    PubMed Central

    Luu, Hung N; Dahlstrom, Kristina R; Mullen, Patricia Dolan; VonVille, Helena M; Scheurer, Michael E

    2013-01-01

    The effectiveness of screening programs for cervical cancer has benefited from the inclusion of Human papillomavirus (HPV) DNA assays; which assay to choose, however, is not clear based on previous reviews. Our review addressed test accuracy of Hybrid Capture II (HCII) and polymerase chain reaction (PCR) assays based on studies with stronger designs and with more clinically relevant outcomes. We searched OvidMedline, PubMed, and the Cochrane Library for English language studies comparing both tests, published 1985–2012, with cervical dysplasia defined by the Bethesda classification. Meta-analysis provided pooled sensitivity, specificity, and 95% confidence intervals (CIs); meta-regression identified sources of heterogeneity. From 29 reports, we found that the pooled sensitivity and specificity to detect high-grade squamous intraepithelial lesion (HSIL) was higher for HCII than PCR (0.89 [CI: 0.89–0.90] and 0.85 [CI: 0.84–0.86] vs. 0.73 [CI: 0.73–0.74] and 0.62 [CI: 0.62–0.64]). Both assays had higher accuracy to detect cervical dysplasia in Europe than in Asia-Pacific or North America (diagnostic odd ratio – dOR = 4.08 [CI: 1.39–11.91] and 4.56 [CI: 1.86–11.17] for HCII vs. 2.66 [CI: 1.16–6.53] and 3.78 [CI: 1.50–9.51] for PCR) and accuracy to detect HSIL than atypical squamous cells of undetermined significance (ASCUS)/ low-grade squamous intraepithelial lesion (LSIL) (HCII-dOR = 9.04 [CI: 4.12–19.86] and PCR-dOR = 5.60 [CI: 2.87–10.94]). For HCII, using histology as a gold standard results in higher accuracy than using cytology (dOR = 2.87 [CI: 1.31–6.29]). Based on higher test accuracy, our results support the use of HCII in cervical cancer screening programs. The role of HPV type distribution should be explored to determine the worldwide comparability of HPV test accuracy. PMID:23930214

  4. The confidence-accuracy relationship for eyewitness identification decisions: Effects of exposure duration, retention interval, and divided attention.

    PubMed

    Palmer, Matthew A; Brewer, Neil; Weber, Nathan; Nagesh, Ambika

    2013-03-01

    Prior research points to a meaningful confidence-accuracy (CA) relationship for positive identification decisions. However, there are theoretical grounds for expecting that different aspects of the CA relationship (calibration, resolution, and over/underconfidence) might be undermined in some circumstances. This research investigated whether the CA relationship for eyewitness identification decisions is affected by three, forensically relevant variables: exposure duration, retention interval, and divided attention at encoding. In Study 1 (N = 986), a field experiment, we examined the effects of exposure duration (5 s vs. 90 s) and retention interval (immediate testing vs. a 1-week delay) on the CA relationship. In Study 2 (N = 502), we examined the effects of attention during encoding on the CA relationship by reanalyzing data from a laboratory experiment in which participants viewed a stimulus video under full or divided attention conditions and then attempted to identify two targets from separate lineups. Across both studies, all three manipulations affected identification accuracy. The central analyses concerned the CA relation for positive identification decisions. For the manipulations of exposure duration and retention interval, overconfidence was greater in the more difficult conditions (shorter exposure; delayed testing) than the easier conditions. Only the exposure duration manipulation influenced resolution (which was better for 5 s than 90 s), and only the retention interval manipulation affected calibration (which was better for immediate testing than delayed testing). In all experimental conditions, accuracy and diagnosticity increased with confidence, particularly at the upper end of the confidence scale. Implications for theory and forensic settings are discussed.

  5. The effects of 6-week training programs on throwing accuracy, proprioception, and core endurance in baseball.

    PubMed

    Lust, Kathleen R; Sandrey, Michelle A; Bulger, Sean M; Wilder, Nathan

    2009-08-01

    With a limited number of outcomes-based studies, only recommendations for strength-training and rehabilitation programs can be made. To determine the extent to which throwing accuracy, core stability, and proprioception improved after completion of a 6-week training program that included open kinetic chain (OKC), closed kinetic chain (CKC), and/or core-stability exercises. A 2 x 3 factorial design. Division III college. 19 healthy baseball athletes with a control group of 15. Two 6-week programs including OKC, CKC, and core-stabilization exercises that were progressed each week. Functional throwing-performance index, closed kinetic chain upper extremity stability test, back-extensor test, 45 degrees abdominal-fatigue test, and right- and left-side bridging test. There was no significant difference between groups. An increase was evident in all pretest-to-posttest results, with improvement ranging from 1.36% to 140%. Both of the 6-week training programs could be used to increase throwing accuracy, core stability, and proprioception in baseball.

  6. Satisfaction of Search in Chest Radiography 2015.

    PubMed

    Berbaum, Kevin S; Krupinski, Elizabeth A; Schartz, Kevin M; Caldwell, Robert T; Madsen, Mark T; Hur, Seung; Laroia, Archana T; Thompson, Brad H; Mullan, Brian F; Franken, Edmund A

    2015-11-01

    Two decades have passed since the publication of laboratory studies of satisfaction of search (SOS) in chest radiography. Those studies were performed using film. The current investigation tests for SOS effects in computed radiography of the chest. Sixty-four chest computed radiographs half demonstrating various "test" abnormalities were read twice by 20 radiologists, once with and once without the addition of a simulated pulmonary nodule. Receiver-operating characteristic detection accuracy and decision thresholds were analyzed to study the effects of adding the nodule on detecting the test abnormalities. Results of previous studies were reanalyzed using similar modern techniques. In the present study, adding nodules did not influence detection accuracy for the other abnormalities (P = .93), but did induce a reluctance to report them (P < .001). Adding nodules did not affect inspection time (P = .58) so the reluctance to report was not associated with reduced search. Reanalysis revealed a similar decision threshold shift that had not been recognized in the early studies of SOS in chest radiography (P < .01) in addition to reduced detection accuracy (P < .01). The nature of SOS in chest radiography has changed, but it is not clear why. SOS may be changing as a function of changes in radiology education and practice. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  7. Investigations of interference between electromagnetic transponders and wireless MOSFET dosimeters: a phantom study.

    PubMed

    Su, Zhong; Zhang, Lisha; Ramakrishnan, V; Hagan, Michael; Anscher, Mitchell

    2011-05-01

    To evaluate both the Calypso Systems' (Calypso Medical Technologies, Inc., Seattle, WA) localization accuracy in the presence of wireless metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters of dose verification system (DVS, Sicel Technologies, Inc., Morrisville, NC) and the dosimeters' reading accuracy in the presence of wireless electromagnetic transponders inside a phantom. A custom-made, solid-water phantom was fabricated with space for transponders and dosimeters. Two inserts were machined with positioning grooves precisely matching the dimensions of the transponders and dosimeters and were arranged in orthogonal and parallel orientations, respectively. To test the transponder localization accuracy with/without presence of dosimeters (hypothesis 1), multivariate analyses were performed on transponder-derived localization data with and without dosimeters at each preset distance to detect statistically significant localization differences between the control and test sets. To test dosimeter dose-reading accuracy with/without presence of transponders (hypothesis 2), an approach of alternating the transponder presence in seven identical fraction dose (100 cGy) deliveries and measurements was implemented. Two-way analysis of variance was performed to examine statistically significant dose-reading differences between the two groups and the different fractions. A relative-dose analysis method was also used to evaluate transponder impact on dose-reading accuracy after dose-fading effect was removed by a second-order polynomial fit. Multivariate analysis indicated that hypothesis 1 was false; there was a statistically significant difference between the localization data from the control and test sets. However, the upper and lower bounds of the 95% confidence intervals of the localized positional differences between the control and test sets were less than 0.1 mm, which was significantly smaller than the minimum clinical localization resolution of 0.5 mm. For hypothesis 2, analysis of variance indicated that there was no statistically significant difference between the dosimeter readings with and without the presence of transponders. Both orthogonal and parallel configurations had difference of polynomial-fit dose to measured dose values within 1.75%. The phantom study indicated that the Calypso System's localization accuracy was not affected clinically due to the presence of DVS wireless MOSFET dosimeters and the dosimeter-measured doses were not affected by the presence of transponders. Thus, the same patients could be implanted with both transponders and dosimeters to benefit from improved accuracy of radiotherapy treatments offered by conjunctional use of the two systems.

  8. Surface accuracy measurement sensor test on a 50-meter antenna surface model

    NASA Technical Reports Server (NTRS)

    Spiers, R. B.; Burcher, E. E.; Stump, C. W.; Saunders, C. G.; Brooks, G. F.

    1984-01-01

    The Surface Accuracy Measurement Sensor (SAMS) is a telescope with a focal plane photo electric detector that senses the lateral position of light source targets in its field of view. After extensive laboratory testing the engineering breadboard sensor system was installed and tested on a 30 degree segment of a 50-meter diameter, mesh surface, antenna model. Test results correlated well with the laboratory tests and indicated accuracies of approximately 0.59 arc seconds at 21 meters range. Test results are presented and recommendations given for sensor improvements.

  9. Technical Note: A Feasibility Study of Using the Flat Panel Detector on Linac for the kV X-ray Generator Test.

    PubMed

    Cai, Bin; Dolly, Steven; Kamal, Gregory; Yaddanapudi, Sridhar; Sun, Baozhou; Goddu, S Murty; Mutic, Sasa; Li, Hua

    2018-04-28

    To investigate the feasibility of using kV flat panel detector on linac for consistency evaluations of kV X-ray generator performance. An in-house designed aluminum (Al) array phantom with six 9×9 cm 2 square regions having various thickness was proposed and used in this study. Through XML script-driven image acquisition, kV images with various acquisition settings were obtained using the kV flat panel detector. Utilizing pre-established baseline curves, the consistency of X-ray tube output characteristics including tube voltage accuracy, exposure accuracy and exposure linearity were assessed through image quality assessment metrics including ROI mean intensity, ROI standard deviation (SD) and noise power spectrums (NPS). The robustness of this method was tested on two linacs for a three-month period. With the proposed method, tube voltage accuracy can be verified through conscience check with a 2% tolerance and 2 kVp intervals for forty different kVp settings. The exposure accuracy can be tested with a 4% consistency tolerance for three mAs settings over forty kVp settings. The exposure linearity tested with three mAs settings achieved a coefficient of variation (CV) of 0.1. We proposed a novel approach that uses the kV flat panel detector available on linac for X-ray generator test. This approach eliminates the inefficiencies and variability associated with using third party QA detectors while enabling an automated process. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  10. Accuracy of the radioactive copper incorporation test in the diagnosis of Wilson disease.

    PubMed

    Członkowska, Anna; Rodo, Maria; Wierzchowska-Ciok, Agata; Smolinski, Lukasz; Litwin, Tomasz

    2018-02-08

    In Wilson disease (WD), copper accumulates in the liver and other tissues because of mutations in the ATP7B copper transporter gene. Early and effective anticopper treatment is crucial. However, routine diagnostic methods based on clinical findings, copper metabolism tests, liver biopsies and DNA analyses do not always provide a conclusive diagnosis. The aim was to evaluate radioactive copper incorporation as a diagnostic test. We included cases with a diagnosis of WD supported by radiocopper testing and later, when available, confirmed by DNA analysis. Incorporation of 64 Cu was measured at 2, 24 and 48 hours following intravenous injection. Diagnostic accuracy (area under the receiver operating characteristic curve [AUC]), sensitivity, specificity and predictive value were assessed for 24 hours/2 hours and 48 hours/2 hours 64 Cu ratios and compared with serum measurements of ceruloplasmin, copper, non-ceruloplasmin-bound copper and urinary 24-hours copper excretion. Patients having two pathogenic ATP7B mutations (homozygotes/compound heterozygotes) (n = 74) had significantly lower 24 hours/2 hours and 48 hours/2 hours 64 Cu ratios than heterozygote controls (n = 21) (mean 0.14 and 0.12 vs 0.49 and 0.63, respectively; both P < .001). Of note, 24 hours/2 hours and 48 hours/2 hours 64 Cu ratios had excellent diagnostic accuracy, with AUCs approaching 1, and only 24-hours urinary copper excretion displayed similar positive features. Other copper metabolism tests studied had lower accuracy, specificity and sensitivity. The radioactive copper test had excellent diagnostic accuracy and may be useful in the evaluation of new therapies aimed at restoring ATP7B function. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. The accuracy of assessment of walking distance in the elective spinal outpatients setting.

    PubMed

    Okoro, Tosan; Qureshi, Assad; Sell, Beulah; Sell, Philip

    2010-02-01

    Self reported walking distance is a clinically relevant measure of function. The aim of this study was to define patient accuracy and understand factors that might influence perceived walking distance in an elective spinal outpatients setting. A prospective cohort study. 103 patients were asked to perform one test of distance estimation and 2 tests of functional distance perception using pre-measured landmarks. Standard spine specific outcomes included the patient reported claudication distance, Oswestry disability index (ODI), Low Back Outcome Score (LBOS), visual analogue score (VAS) for leg and back, and other measures. There are over-estimators and under-estimators. Overall, the accuracy to within 9.14 metres (m) (10 yards) was poor at only 5% for distance estimation and 40% for the two tests of functional distance perception. Distance: Actual distance 111 m; mean response 245 m (95% CI 176.3-314.7), Functional test 1 actual distance 29.2 m; mean response 71.7 m (95% CI 53.6-88.9) Functional test 2 actual distance 19.6 m; mean response 47.4 m (95% CI 35.02-59.95). Surprisingly patients over 60 years of age (n = 43) are twice as accurate with each test performed compared to those under 60 (n = 60) (average 70% overestimation compared to 140%; p = 0.06). Patients in social class I (n = 18) were more accurate than those in classes II-V (n = 85): There was a positive correlation between poor accuracy and increasing MZD (Pearson's correlation coefficient 0.250; p = 0.012). ODI, LBOS and other parameters measured showed no correlation. Subjective distance perception and estimation is poor in this population. Patients over 60 and those with a professional background are more accurate but still poor.

  12. A rigorous test of the accuracy of USGS digital elevation models in forested areas of Oregon and Washington.

    Treesearch

    Ward W. Carson; Stephen E. Reutebuch

    1997-01-01

    A procedure for performing a rigorous test of elevational accuracy of DEMs using independent ground coordinate data digitized photogrammetrically from aerial photography is presented. The accuracy of a sample set of 23 DEMs covering National Forests in Oregon and Washington was evaluated. Accuracy varied considerably between eastern and western parts of Oregon and...

  13. Molecular testing for Lynch syndrome in people with colorectal cancer: systematic reviews and economic evaluation.

    PubMed

    Snowsill, Tristan; Coelho, Helen; Huxley, Nicola; Jones-Hughes, Tracey; Briscoe, Simon; Frayling, Ian M; Hyde, Chris

    2017-09-01

    Inherited mutations in deoxyribonucleic acid (DNA) mismatch repair (MMR) genes lead to an increased risk of colorectal cancer (CRC), gynaecological cancers and other cancers, known as Lynch syndrome (LS). Risk-reducing interventions can be offered to individuals with known LS-causing mutations. The mutations can be identified by comprehensive testing of the MMR genes, but this would be prohibitively expensive in the general population. Tumour-based tests - microsatellite instability (MSI) and MMR immunohistochemistry (IHC) - are used in CRC patients to identify individuals at high risk of LS for genetic testing. MLH1 (MutL homologue 1) promoter methylation and BRAF V600E testing can be conducted on tumour material to rule out certain sporadic cancers. To investigate whether testing for LS in CRC patients using MSI or IHC (with or without MLH1 promoter methylation testing and BRAF V600E testing) is clinically effective (in terms of identifying Lynch syndrome and improving outcomes for patients) and represents a cost-effective use of NHS resources. Systematic reviews were conducted of the published literature on diagnostic test accuracy studies of MSI and/or IHC testing for LS, end-to-end studies of screening for LS in CRC patients and economic evaluations of screening for LS in CRC patients. A model-based economic evaluation was conducted to extrapolate long-term outcomes from the results of the diagnostic test accuracy review. The model was extended from a model previously developed by the authors. Ten studies were identified that evaluated the diagnostic test accuracy of MSI and/or IHC testing for identifying LS in CRC patients. For MSI testing, sensitivity ranged from 66.7% to 100.0% and specificity ranged from 61.1% to 92.5%. For IHC, sensitivity ranged from 80.8% to 100.0% and specificity ranged from 80.5% to 91.9%. When tumours showing low levels of MSI were treated as a positive result, the sensitivity of MSI testing increased but specificity fell. No end-to-end studies of screening for LS in CRC patients were identified. Nine economic evaluations of screening for LS in CRC were identified. None of the included studies fully matched the decision problem and hence a new economic evaluation was required. The base-case results in the economic evaluation suggest that screening for LS in CRC patients using IHC, BRAF V600E and MLH1 promoter methylation testing would be cost-effective at a threshold of £20,000 per quality-adjusted life-year (QALY). The incremental cost-effectiveness ratio for this strategy was £11,008 per QALY compared with no screening. Screening without tumour tests is not predicted to be cost-effective. Most of the diagnostic test accuracy studies identified were rated as having a risk of bias or were conducted in unrepresentative samples. There was no direct evidence that screening improves long-term outcomes. No probabilistic sensitivity analysis was conducted. Systematic review evidence suggests that MSI- and IHC-based testing can be used to identify LS in CRC patients, although there was heterogeneity in the methods used in the studies identified and the results of the studies. There was no high-quality empirical evidence that screening improves long-term outcomes and so an evidence linkage approach using modelling was necessary. Key determinants of whether or not screening is cost-effective are the accuracy of tumour-based tests, CRC risk without surveillance, the number of relatives identified for cascade testing, colonoscopic surveillance effectiveness and the acceptance of genetic testing. Future work should investigate screening for more causes of hereditary CRC and screening for LS in endometrial cancer patients. This study is registered as PROSPERO CRD42016033879. The National Institute for Health Research Health Technology Assessment programme.

  14. Accuracy of malaria diagnosis by microscopy, rapid diagnostic test, and PCR methods and evidence of antimalarial overprescription in non-severe febrile patients in two Tanzanian hospitals.

    PubMed

    Nicastri, Emanuele; Bevilacqua, Nazario; Sañé Schepisi, Monica; Paglia, Maria G; Meschi, Silvia; Ame, Shaali M; Mohamed, Jape A; Mangi, Sabina; Fumakule, Robert; Di Caro, Antonino; Capobianchi, Maria R; Kitua, Andrew; Molteni, Fabrizio; Racalbuto, Vincenzo; Ippolito, Giuseppe

    2009-05-01

    The study was aimed to evaluate the malaria over/underdiagnosis and over/underprescription of antimalarial drugs. Between February and March 2007 blood samples were collected from 336 non-severe febrile outpatients attended in two peripheral Tanzanian hospitals. Microscopy and a rapid diagnostic test (RDT) were done locally and the accuracy evaluated by qualitative polymerase chain reaction (PCR) for Plasmodium spp. The testing was performed at National Institute for Infectious Diseases Lazzaro Spallanzani (INMI), Rome, Italy. As a result of PCR, we identified 26 malaria cases out of 336 (7.7%) patients. Microscopy and RDT accuracies were 93.5% and 97.6%, respectively. Overprescription and underdiagnosis rates were 29.3% and 30.8%, respectively. On-field training, clinical management of febrile illness, and malaria microscopy in remote settings should be considered.

  15. Examining the Classification Accuracy of a Vocabulary Screening Measure with Preschool Children

    ERIC Educational Resources Information Center

    Marcotte, Amanda M.; Clemens, Nathan H.; Parker, Christopher; Whitcomb, Sara A.

    2016-01-01

    This study investigated the classification accuracy of the "Dynamic Indicators of Vocabulary Skills" (DIVS) as a preschool vocabulary screening measure. With a sample of 240 preschoolers, fall and winter DIVS scores were used to predict year-end vocabulary risk using the 25th percentile on the "Peabody Picture Vocabulary Test--Third…

  16. Advanced Mind-Reading in Adults with Asperger Syndrome

    ERIC Educational Resources Information Center

    Ponnet, Koen S.; Roeyers, Herbert; Buysse, Ann; De Clercq, Armand; Van Der Heyden, Eva

    2004-01-01

    This study investigated the mind-reading abilities of 19 adults with Asperger syndrome and 19 typically developing adults. Two static mind-reading tests and a more naturalistic empathic accuracy task were used. In the empathic accuracy task, participants attempted to infer the thoughts and feelings of target persons, while viewing a videotape of…

  17. Concurrent Validity and Classification Accuracy of Curriculum-Based Measurement for Written Expression

    ERIC Educational Resources Information Center

    Furey, William M.; Marcotte, Amanda M.; Hintze, John M.; Shackett, Caroline M.

    2016-01-01

    The study presents a critical analysis of written expression curriculum-based measurement (WE-CBM) metrics derived from 3- and 10-min test lengths. Criterion validity and classification accuracy were examined for Total Words Written (TWW), Correct Writing Sequences (CWS), Percent Correct Writing Sequences (%CWS), and Correct Minus Incorrect…

  18. Working Memory Components as Predictors of Children's Mathematical Word Problem Solving

    ERIC Educational Resources Information Center

    Zheng, Xinhua; Swanson, H. Lee; Marcoulides, George A.

    2011-01-01

    This study determined the working memory (WM) components (executive, phonological loop, and visual-spatial sketchpad) that best predicted mathematical word problem-solving accuracy of elementary school children in Grades 2, 3, and 4 (N = 310). A battery of tests was administered to assess problem-solving accuracy, problem-solving processes, WM,…

  19. Emotion Recognition Ability: A Multimethod-Multitrait Study.

    ERIC Educational Resources Information Center

    Gaines, Margie; And Others

    A common paradigm in measuring the ability to recognize facial expressions of emotion is to present photographs of facial expressions and to ask subjects to identify the emotion. The Affect Blend Test (ABT) uses this method of assessment and is scored for accuracy on specific affects as well as total accuracy. Another method of measuring affect…

  20. The diagnostic accuracy of Clinical Dehydration Scale in identifying dehydration in children with acute gastroenteritis: a systematic review.

    PubMed

    Falszewska, Anna; Dziechciarz, Piotr; Szajewska, Hania

    2014-10-01

    To systematically update diagnostic accuracy of the Clinical Dehydration Scale (CDS) in clinical recognition of dehydration in children with acute gastroenteritis. Six databases were searched for diagnostic accuracy studies in which population were children aged 1 to 36 months with acute gastroenteritis; index test was the CDS; and reference test was post-illness weight gain. Three studies involving 360 children were included. Limited evidence showed that in high-income countries the CDS provides strong diagnostic accuracy for ruling in moderate and severe (>6%) dehydration (positive likelihood ratio 5.2-6.6), but has limited value for ruling it out (negative likelihood ratio 0.4-0.55). In low-income countries, the CDS has limited value either for ruling moderate or severe dehydration in or out. In both settings, the CDS had limited value for ruling in or out dehydration <3% or dehydration 3% to 6%. The CDS can help assess moderate to severe dehydration in high-income settings. Given the limited data, the evidence should be viewed with caution. © The Author(s) 2014.

  1. Usefulness of the volume-viscosity swallow test for screening dysphagia in subacute stroke patients in rehabilitation income.

    PubMed

    Guillén-Solà, Anna; Marco, Ester; Martínez-Orfila, Joan; Donaire Mejías, M Fernanda; Depolo Passalacqua, Marina; Duarte, Esther; Escalada, Ferran

    2013-01-01

    Swallowing disorders affect up to 35-85% of patients with stroke. Dysphagia complications can lead to malnutrition, dehydration, bronchoaspirative pneumonia and death, and have impact on health care costs. To evaluate the clinical screening capacity of the Volume Viscosity Swallow Test (V-VST) for oropharyngeal dysphagia and aspiration in a homogeneous stroke patient sample. Cohort study of 52 stroke patients in a subacute phase. Piecemeal deglutition and oropharyngeal residue were considered signs of impaired efficacy and cough, fall in oxygen saturation and voice changes, signs of impaired safety. Sensitivity, specificity, positive and negative predictive values, accuracy and likelihood ratios were calculated for V-VST results and compared with those of videofluoroscopy (VFS), the gold standard for studies on swallowing disorders. The V-VST is a highly sensitive and specific test to detect aspiration with sensitivity of 88.2% and specificity of 71.4%; negative predictive value was 92.6%; accuracy index was 0.74. Sensitivity and specificity for penetration were 34.3% and 70.6%, respectively; accuracy was 32%. The V-VST is low in cost, easy to use and very sensitive, meeting the requirements of oropharyngeal dysphagia and aspiration screening test in subacute stroke patients.

  2. [Method for evaluating the positional accuracy of a six-degrees-of-freedom radiotherapy couch using high definition digital cameras].

    PubMed

    Takemura, Akihiro; Ueda, Shinichi; Noto, Kimiya; Kurata, Yuichi; Shoji, Saori

    2011-01-01

    In this study, we proposed and evaluated a positional accuracy assessment method with two high-resolution digital cameras for add-on six-degrees-of-freedom radiotherapy (6D) couches. Two high resolution digital cameras (D5000, Nikon Co.) were used in this accuracy assessment method. These cameras were placed on two orthogonal axes of a linear accelerator (LINAC) coordinate system and focused on the isocenter of the LINAC. Pictures of a needle that was fixed on the 6D couch were taken by the cameras during couch motions of translation and rotation of each axis. The coordinates of the needle in the pictures were obtained using manual measurement, and the coordinate error of the needle was calculated. The accuracy of a HexaPOD evo (Elekta AB, Sweden) was evaluated using this method. All of the mean values of the X, Y, and Z coordinate errors in the translation tests were within ±0.1 mm. However, the standard deviation of the Z coordinate errors in the Z translation test was 0.24 mm, which is higher than the others. In the X rotation test, we found that the X coordinate of the rotational origin of the 6D couch was shifted. We proposed an accuracy assessment method for a 6D couch. The method was able to evaluate the accuracy of the motion of only the 6D couch and revealed the deviation of the origin of the couch rotation. This accuracy assessment method is effective for evaluating add-on 6D couch positioning.

  3. A heel-strike real-time auditory feedback device to promote motor learning in children who have cerebral palsy: a pilot study to test device accuracy and feasibility to use a music and dance-based learning paradigm.

    PubMed

    Pitale, Jaswandi Tushar; Bolte, John H

    2018-01-01

    Cerebral palsy (CP) is a developmental disorder of movement and posture that occurs due to damage to the developing nervous system. As part of therapy, wearable sensors that trigger interactive feedback may provide multi-sensory guidance and motivation. A prototype of a heel-strike real-time feedback system has been developed which records the number of heel strikes during gait and indicates successful heel contact through real-time auditory feedback. The first aim of this feasibility study was to test the prototype accuracy.Since the end user for this device is a child, the device should be esthetically appealing and sufficiently motivating for children to perform repetitive challenging therapeutic movements. The second aim of this study was to collect feedback from the subjects with regard to the device usability and understand if the bell sound used as feedback used was motivating enough for children to continue using the prototype. This would help us in developing the next generation of the device. The prototype was tested with typically developing children and children who have CP. The accuracy in detecting heel strikes was calculated. As part of the study, the subjects were also asked questions to test the device compliance and acceptability of the musical beats with the pediatric population. The device accuracy in identifying heel strikes is 97.44% (95% CI 96.31, 98.88%). The subjects did not show any hesitation to put on the device and the sound feedback motivated them to move. Based on this pilot study, a minimum age limit of 5 years is appropriate and the intervention study should be conducted for no more than 30 min per week. The pilot study showed that a main study can be conducted to test auditory feedback as an intervention to promote motor learning in children who have cerebral palsy. No adverse event or safety issues were reported in the feasibility study.

  4. Exercise testing in children with Wolff-Parkinson-White syndrome: what is its value?

    PubMed

    Dalili, M; Vahidshahi, K; Aarabi-Moghaddam, M Y; Rao, J Y; Brugada, P

    2014-10-01

    This study was conducted to evaluate the accuracy of exercise testing for predicting accessory pathway characteristics in children with Wolff-Parkinson-White (WPW) syndrome. The study enrolled 37 children with WPW syndrome and candidates for invasive electrophysiologic study (EPS). Exercise testing was performed for all the study participants before the invasive study. Data from the invasive EPS were compared with findings from the exercise testing. The sudden disappearance of the delta (Δ) wave was seen in 10 cases (27 %). No significant correlation was found between the Δ wave disappearance and the antegrade effective refractory period of the accessory pathway (AERP-AP) or the shortest pre-excited RR interval (SPERRI). The sensitivity, specificity, and positive and negative predictive values of Δ wave disappearance, based on AERP-AP as gold standard, were respectively 29.4, 80, 71.4, and 40 %. The corresponding values with SPERRI as the gold standard were respectively 23.8, 71.4, 71.4 and 23.8 %. Exercise testing has a medium to low rate of accuracy in detecting low-risk WPW syndrome patients in the pediatric age group.

  5. The correlation between malaria RDT (Paracheck pf.®) faint test bands and microscopy in the diagnosis of malaria in Malawi.

    PubMed

    Makuuchi, Ryoko; Jere, Sandy; Hasejima, Nobuchika; Chigeda, Thoms; Gausi, January

    2017-05-02

    Faint test bands of Paracheck Pf.® are interpreted as malaria positive according to world health organization (WHO) guideline. However if there are conspicuous number of faint test bands, a performance of Paracheck Pf.® could be influenced depending on whether interpreting faint test bands as malaria positive or negative. Finding out the frequency and accurate interpretation of faint test bands are important to prevent the overdiagnosis and drug resistance. A cross-sectional, descriptive study was conducted to find out the frequency of faint test bands and evaluate the performance of Paracheck Pf.® by sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of diagnosis of Paracheck Pf.® using microscopy as the gold standard. 388 suspected patients with malaria in Malawi were recruited in this study. Malaria rapid diagnostic tests (RDTs) and microscopy were used and patients' information which includes age, sex, body temperature and signs or symptoms of malaria were recorded. Among all patients involved in the study, 29.1% (113/388) were found malaria positive by RDT. Overall 5.4% (21/388) of all Paracheck Pf.® tests resulted in a "faint test band" and 85.7% (18/21) corresponded with malaria negative by microscopy. Faint test bands which corresponded with malaria positive by microscopy were lower parasite density and there are no patients who showed definitive symptom of malaria, such as fever. When Paracheck Pf.® "faint test bands" were classified as positive, accuracy of diagnosis was 76.5% (95% CI 72%-80.7%) as compared to 80.4% (95% CI 76.1%-84.2%) when Paracheck Pf.® "faint test bands" were classified as negative. This study shows that frequency of faint test bands is 5.4% in all malaria RDTs. The accuracy of diagnosis was improved when faint test bands were interpreted as malaria negative. However information and data obtained in this study may not be enough and more intensive research including a frequency and property of faint test bands is needed for significant interpretation of faint test bands.

  6. Laboratory testing of a saliva-alcohol test device by Enzymatics, Inc.

    DOT National Transportation Integrated Search

    1992-12-01

    This study examined the accuracy of a new saliva-alcohol test device (Enzymatics, Inc. "Q.E.D.-A150") at nine different blood alcohol concentrations (BACs) under three temperature conditions. However, it did not assess the saliva collection procedure...

  7. Diagnostic accuracy and prognostic significance of blood fibrosis tests and liver stiffness measurement by FibroScan in non-alcoholic fatty liver disease.

    PubMed

    Boursier, Jérôme; Vergniol, Julien; Guillet, Anne; Hiriart, Jean-Baptiste; Lannes, Adrien; Le Bail, Brigitte; Michalak, Sophie; Chermak, Faiza; Bertrais, Sandrine; Foucher, Juliette; Oberti, Frédéric; Charbonnier, Maude; Fouchard-Hubert, Isabelle; Rousselet, Marie-Christine; Calès, Paul; de Lédinghen, Victor

    2016-09-01

    NAFLD is highly prevalent but only a small subset of patients develop advanced liver fibrosis with impaired liver-related prognosis. We aimed to compare blood fibrosis tests and liver stiffness measurement (LSM) by FibroScan for the diagnosis of liver fibrosis and the evaluation of prognosis in NAFLD. Diagnostic accuracy was evaluated in a cross-sectional study including 452 NAFLD patients with liver biopsy (NASH-CRN fibrosis stage), LSM, and eight blood fibrosis tests (BARD, NAFLD fibrosis score, FibroMeter(NAFLD), aspartate aminotransferase to platelet ratio index (APRI), FIB4, FibroTest, Hepascore, FibroMeter(V2G)). Prognostic accuracy was evaluated in a longitudinal study including 360 NAFLD patients. LSM and FibroMeter(V2G) were the two best-performing tests in the cross-sectional study: AUROCs for advanced fibrosis (F3/4) were, respectively, 0.831±0.019 and 0.817±0.020 (p⩽0.041 vs. other tests); rates of patients with ⩾90% negative/positive predictive values for F3/4 were 56.4% and 46.7% (p<0.001 vs. other tests); Obuchowski indexes were 0.834±0.014 and 0.798±0.016 (p⩽0.036 vs. other tests). Two fibrosis classifications were developed to precisely estimate the histological fibrosis stage from LSM or FibroMeter(V2G) results without liver biopsy (diagnostic accuracy, respectively: 80.8% vs. 77.4%, p=0.190). Kaplan-Meier curves in the longitudinal study showed that both classifications categorised NAFLD patients into subgroups with significantly different prognoses (p<0.001): the higher was the class of the fibrosis classification, the worse was the prognosis. LSM and FibroMeter(V2G) were the most accurate of nine evaluated tests for the non-invasive diagnosis of liver fibrosis in NAFLD. LSM and FibroMeter(V2G) fibrosis classifications help physicians estimate both fibrosis stage and patient prognosis in clinical practice. The amount of liver fibrosis is the main determinant of the liver-related prognosis in patients with non-alcoholic fatty liver disease (NAFLD). We evaluated eight blood tests and FibroScan in a cross-sectional diagnostic study and found that FibroScan and the blood test FibroMeter(V2G) were the two most accurate tests for the non-invasive evaluation of liver fibrosis in NAFLD. A longitudinal prognostic study showed these two tests initially developed for the diagnosis are also prognostic markers as they allow for the stratification of NAFLD patients in several subgroups with significantly different prognosis. Copyright © 2016 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.

  8. High Order Numerical Methods for LES of Turbulent Flows with Shocks

    NASA Technical Reports Server (NTRS)

    Kotov, D. V.; Yee, H. C.; Hadjadj, A.; Wray, A.; Sjögreen, B.

    2014-01-01

    Simulation of turbulent flows with shocks employing explicit subgrid-scale (SGS) filtering may encounter a loss of accuracy in the vicinity of a shock. In this work we perform a comparative study of different approaches to reduce this loss of accuracy within the framework of the dynamic Germano SGS model. One of the possible approaches is to apply Harten's subcell resolution procedure to locate and sharpen the shock, and to use a one-sided test filter at the grid points adjacent to the exact shock location. The other considered approach is local disabling of the SGS terms in the vicinity of the shock location. In this study we use a canonical shock-turbulence interaction problem for comparison of the considered modifications of the SGS filtering procedure. For the considered test case both approaches show a similar improvement in the accuracy near the shock.

  9. Laboratory and field tests of the Sutron RLR-0003-1 water level sensor

    USGS Publications Warehouse

    Fulford, Janice M.; Bryars, R. Scott

    2015-01-01

    Three Sutron RLR-0003-1 water level sensors were tested in laboratory conditions to evaluate the accuracy of the sensor over the manufacturer’s specified operating temperature and distance-to-water ranges. The sensor was also tested for compliance to SDI-12 communication protocol and in field conditions at a U.S. Geological Survey (USGS) streamgaging site. Laboratory results were compared to the manufacturer’s accuracy specification for water level and to the USGS Office of Surface Water (OSW) policy requirement that water level sensors have a measurement uncertainty of no more than 0.01 foot or 0.20 percent of the indicated reading. Except for one sensor, the differences for the temperature testing were within 0.05 foot and the average measurements for the sensors were within the manufacturer’s accuracy specification. Two of the three sensors were within the manufacturer’s specified accuracy and met the USGS accuracy requirements for the laboratory distance to water testing. Three units passed a basic SDI-12 communication compliance test. Water level measurements made by the Sutron RLR-0003-1 during field testing agreed well with those made by the bubbler system and a Design Analysis Associates (DAA) H3613 radar, and they met the USGS accuracy requirements when compared to the wire-weight gage readings.

  10. Imaging modalities for the non-invasive diagnosis of endometriosis.

    PubMed

    Nisenblat, Vicki; Bossuyt, Patrick M M; Farquhar, Cindy; Johnson, Neil; Hull, M Louise

    2016-02-26

    About 10% of women of reproductive age suffer from endometriosis. Endometriosis is a costly chronic disease that causes pelvic pain and subfertility. Laparoscopy, the gold standard diagnostic test for endometriosis, is expensive and carries surgical risks. Currently, no non-invasive tests that can be used to accurately diagnose endometriosis are available in clinical practice. This is the first review of diagnostic test accuracy of imaging tests for endometriosis that uses Cochrane methods to provide an update on the rapidly expanding literature in this field. • To provide estimates of the diagnostic accuracy of imaging modalities for the diagnosis of pelvic endometriosis, ovarian endometriosis and deeply infiltrating endometriosis (DIE) versus surgical diagnosis as a reference standard.• To describe performance of imaging tests for mapping of deep endometriotic lesions in the pelvis at specific anatomical sites.Imaging tests were evaluated as replacement tests for diagnostic surgery and as triage tests that would assist decision making regarding diagnostic surgery for endometriosis. We searched the following databases to 20 April 2015: MEDLINE, CENTRAL, EMBASE, CINAHL, PsycINFO, Web of Science, LILACS, OAIster, TRIP, ClinicalTrials.gov, MEDION, DARE, and PubMed. Searches were not restricted to a particular study design or language nor to specific publication dates. The search strategy incorporated words in the title, abstracts, text words across the record and medical subject headings (MeSH). We considered published peer-reviewed cross-sectional studies and randomised controlled trials of any size that included prospectively recruited women of reproductive age suspected of having one or more of the following target conditions: endometrioma, pelvic endometriosis, DIE or endometriotic lesions at specific intrapelvic anatomical locations. We included studies that compared the diagnostic test accuracy of one or more imaging modalities versus findings of surgical visualisation of endometriotic lesions. Two review authors independently collected and performed a quality assessment of data from each study. For each imaging test, data were classified as positive or negative for surgical detection of endometriosis, and sensitivity and specificity estimates were calculated. If two or more tests were evaluated in the same cohort, each was considered as a separate data set. We used the bivariate model to obtain pooled estimates of sensitivity and specificity when sufficient data sets were available. Predetermined criteria for a clinically useful imaging test to replace diagnostic surgery included sensitivity ≥ 94% and specificity ≥ 79%. Criteria for triage tests were set at sensitivity ≥ 95% and specificity ≥ 50%, ruling out the diagnosis with a negative result (SnNout test - if sensitivity is high, a negative test rules out pathology) or at sensitivity ≥ 50% with specificity ≥ 95%, ruling in the diagnosis with a positive result (SpPin test - if specificity is high, a positive test rules in pathology). We included 49 studies involving 4807 women: 13 studies evaluated pelvic endometriosis, 10 endometriomas and 15 DIE, and 33 studies addressed endometriosis at specific anatomical sites. Most studies were of poor methodological quality. The most studied modalities were transvaginal ultrasound (TVUS) and magnetic resonance imaging (MRI), with outcome measures commonly demonstrating diversity in diagnostic estimates; however, sources of heterogeneity could not be reliably determined. No imaging test met the criteria for a replacement or triage test for detecting pelvic endometriosis, albeit TVUS approached the criteria for a SpPin triage test. For endometrioma, TVUS (eight studies, 765 participants; sensitivity 0.93 (95% confidence interval (CI) 0.87, 0.99), specificity 0.96 (95% CI 0.92, 0.99)) qualified as a SpPin triage test and approached the criteria for a replacement and SnNout triage test, whereas MRI (three studies, 179 participants; sensitivity 0.95 (95% CI 0.90, 1.00), specificity 0.91 (95% CI 0.86, 0.97)) met the criteria for a replacement and SnNout triage test and approached the criteria for a SpPin test. For DIE, TVUS (nine studies, 12 data sets, 934 participants; sensitivity 0.79 (95% CI 0.69, 0.89) and specificity 0.94 (95% CI 0.88, 1.00)) approached the criteria for a SpPin triage test, and MRI (six studies, seven data sets, 266 participants; sensitivity 0.94 (95% CI 0.90, 0.97), specificity 0.77 (95% CI 0.44, 1.00)) approached the criteria for a replacement and SnNout triage test. Other imaging tests assessed in small individual studies could not be statistically evaluated.TVUS met the criteria for a SpPin triage test in mapping DIE to uterosacral ligaments, rectovaginal septum, vaginal wall, pouch of Douglas (POD) and rectosigmoid. MRI met the criteria for a SpPin triage test for POD and vaginal and rectosigmoid endometriosis. Transrectal ultrasonography (TRUS) might qualify as a SpPin triage test for rectosigmoid involvement but could not be adequately assessed for other anatomical sites because heterogeneous data were scant. Multi-detector computerised tomography enema (MDCT-e) displayed the highest diagnostic performance for rectosigmoid and other bowel endometriosis and met the criteria for both SpPin and SnNout triage tests, but studies were too few to provide meaningful results.Diagnostic accuracies were higher for TVUS with bowel preparation (TVUS-BP) and rectal water contrast (RWC-TVS) and for 3.0TMRI than for conventional methods, although the paucity of studies precluded statistical evaluation. None of the evaluated imaging modalities were able to detect overall pelvic endometriosis with enough accuracy that they would be suggested to replace surgery. Specifically for endometrioma, TVUS qualified as a SpPin triage test. MRI displayed sufficient accuracy to suggest utility as a replacement test, but the data were too scant to permit meaningful conclusions. TVUS could be used clinically to identify additional anatomical sites of DIE compared with MRI, thus facilitating preoperative planning. Rectosigmoid endometriosis was the only site that could be accurately mapped by using TVUS, TRUS, MRI or MDCT-e. Studies evaluating recent advances in imaging modalities such as TVUS-BP, RWC-TVS, 3.0TMRI and MDCT-e were observed to have high diagnostic accuracies but were too few to allow prudent evaluation of their diagnostic role. In view of the low quality of most of the included studies, the findings of this review should be interpreted with caution. Future well-designed diagnostic studies undertaken to compare imaging tests for diagnostic test accuracy and costs are recommended.

  11. Errors of car wheels rotation rate measurement using roller follower on test benches

    NASA Astrophysics Data System (ADS)

    Potapov, A. S.; Svirbutovich, O. A.; Krivtsov, S. N.

    2018-03-01

    The article deals with rotation rate measurement errors, which depend on the motor vehicle rate, on the roller, test benches. Monitoring of the vehicle performance under operating conditions is performed on roller test benches. Roller test benches are not flawless. They have some drawbacks affecting the accuracy of vehicle performance monitoring. Increase in basic velocity of the vehicle requires increase in accuracy of wheel rotation rate monitoring. It determines the degree of accuracy of mode identification for a wheel of the tested vehicle. To ensure measurement accuracy for rotation velocity of rollers is not an issue. The problem arises when measuring rotation velocity of a car wheel. The higher the rotation velocity of the wheel is, the lower the accuracy of measurement is. At present, wheel rotation frequency monitoring on roller test benches is carried out by following-up systems. Their sensors are rollers following wheel rotation. The rollers of the system are not kinematically linked to supporting rollers of the test bench. The roller follower is forced against the wheels of the tested vehicle by means of a spring-lever mechanism. Experience of the test bench equipment operation has shown that measurement accuracy is satisfactory at small rates of vehicles diagnosed on roller test benches. With a rising diagnostics rate, rotation velocity measurement errors occur in both braking and pulling modes because a roller spins about a tire tread. The paper shows oscillograms of changes in wheel rotation velocity and rotation velocity measurement system’s signals when testing a vehicle on roller test benches at specified rates.

  12. Diagnosis of Dementia by Machine learning methods in Epidemiological studies: a pilot exploratory study from south India.

    PubMed

    Bhagyashree, Sheshadri Iyengar Raghavan; Nagaraj, Kiran; Prince, Martin; Fall, Caroline H D; Krishna, Murali

    2018-01-01

    There are limited data on the use of artificial intelligence methods for the diagnosis of dementia in epidemiological studies in low- and middle-income country (LMIC) settings. A culture and education fair battery of cognitive tests was developed and validated for population based studies in low- and middle-income countries including India by the 10/66 Dementia Research Group. We explored the machine learning methods based on the 10/66 battery of cognitive tests for the diagnosis of dementia based in a birth cohort study in South India. The data sets for 466 men and women for this study were obtained from the on-going Mysore Studies of Natal effect of Health and Ageing (MYNAH), in south India. The data sets included: demographics, performance on the 10/66 cognitive function tests, the 10/66 diagnosis of mental disorders and population based normative data for the 10/66 battery of cognitive function tests. Diagnosis of dementia from the rule based approach was compared against the 10/66 diagnosis of dementia. We have applied machine learning techniques to identify minimal number of the 10/66 cognitive function tests required for diagnosing dementia and derived an algorithm to improve the accuracy of dementia diagnosis. Of 466 subjects, 27 had 10/66 diagnosis of dementia, 19 of whom were correctly identified as having dementia by Jrip classification with 100% accuracy. This pilot exploratory study indicates that machine learning methods can help identify community dwelling older adults with 10/66 criterion diagnosis of dementia with good accuracy in a LMIC setting such as India. This should reduce the duration of the diagnostic assessment and make the process easier and quicker for clinicians, patients and will be useful for 'case' ascertainment in population based epidemiological studies.

  13. Back to Anatomy: Improving Landmarking Accuracy of Clinical Procedures Using a Novel Approach to Procedural Teaching.

    PubMed

    Zeller, Michelle; Cristancho, Sayra; Mangel, Joy; Goldszmidt, Mark

    2015-06-01

    Many believe that knowledge of anatomy is essential for performing clinical procedures; however, unlike their surgical counterparts, internal medicine (IM) programs rarely incorporate anatomy review into procedural teaching. This study tested the hypothesis that an educational intervention focused on teaching relevant surface and underlying anatomy would result in improved bone marrow procedure landmarking accuracy. This was a preintervention-postintervention prospective study on landmarking accuracy of consenting IM residents attending their mandatory academic half-day. The intervention included an interactive video and visualization exercise; the video was developed specifically to teach the relevant underlying anatomy and includes views of live volunteers, cadavers, and skeletons. Thirty-one IM residents participated. At pretest, 48% (15/31) of residents landmarked accurately. Inaccuracy of pretest landmarking varied widely (n = 16, mean 20.06 mm; standard deviation 30.03 mm). At posttest, 74% (23/31) of residents accurately performed the procedure. McNemar test revealed a nonsignificant trend toward increased performance at posttest (P = 0.076; unadjusted odds for discordant pairs 3; 95% confidence interval 0.97-9.3). The Wilcoxon signed rank test demonstrated a significant difference between pre- and posttest accuracy in the 16 residents who were inaccurate at pretest (P = 0.004). No association was detected between participant baseline characteristics and pretest accuracy. This study demonstrates that residents who were initially inaccurate were able to significantly improve their landmarking skills by interacting with an educational tool emphasizing the relation between the surface and underlying anatomy. Our results support the use of basic anatomy in teaching bone marrow procedures. Results also support the proper use of video as an effective means for incorporating anatomy teaching around procedural skills.

  14. Diagnostic Accuracy of Tests for Polyuria in Lithium-Treated Patients.

    PubMed

    Kinahan, James Conor; NiChorcorain, Aoife; Cunningham, Sean; Freyne, Aideen; Cooney, Colm; Barry, Siobhan; Kelly, Brendan D

    2015-08-01

    In lithium-treated patients, polyuria increases the risk of dehydration and lithium toxicity. If detected early, it is reversible. Despite its prevalence and associated morbidity in clinical practice, it remains underrecognized and therefore undertreated. The 24-hour urine collection is limited by its convenience and practicality. This study explores the diagnostic accuracy of alternative tests such as questionnaires on subjective polyuria, polydipsia, nocturia (dichotomous and ordinal responses), early morning urine sample osmolality (EMUO), and fluid intake record (FIR). This is a cross-sectional study of 179 lithium-treated patients attending a general adult and an old age psychiatry service. Participants completed the tests after completing an accurate 24-hour urine collection. The diagnostic accuracy of the individual tests was explored using the appropriate statistical techniques. Seventy-nine participants completed all of the tests. Polydipsia severity, EMUO, and FIR significantly differentiated the participants with polyuria (area under the receiver operating characteristic curve of 0.646, 0.760, and 0.846, respectively). Of the tests investigated, the FIR made the largest significant change in the probability that a patient experiences polyuria (<2000 mL/24 hours; interval likelihood ratio, 0.18 and >3500 mL/24 hours; interval likelihood ratio, 14). Symptomatic questioning, EMUO, and an FIR could be used in clinical practice to inform the prescriber of the probability that a lithium-treated patient is experiencing polyuria.

  15. A comparison between on-site immunoassay drug-testing devices and laboratory results.

    PubMed

    Grönholm, M; Lillsunde, P

    2001-09-15

    The aim with this study was to evaluate the accuracy of several on-site testing devices on the market. A part of this study is included in the European Union's (EU's) roadside testing assessment project (ROSITA). An other request for this kind of study came from the Finnish prison department in the Ministry of Justice. The evaluation was performed on both urine assays and oral fluid assays. The on-site test results were compared with laboratory results (gas chromatography-mass spectrometry (GC/MS)). The samples were tested on amphetamines (AMP), cannabinoids (THC), opiates (OPI) and cocaine metabolites (COC). Some of the tests also included a metamphetamine (MET) and a benzodiazepine (BZO) test. Both positive and negative samples were tested. A total of 800 persons and eight on-site devices for urine and two for oral fluid testing were included in this study. Good results were obtained for the urine on-site devices, with accuracies of 93-99% for amphetamines, 97-99% for cannabinoids, 94-98% for opiates and 90-98% for benzodiazepines. However, differences in the ease of performance and interpretation of test result were observed. It was possible to detect amphetamines and opiates in oral fluid by the used on-site devices, but the benzodiazepines and cannabinoids did not fulfil the needs of sensitivity.

  16. Metamemory prediction accuracy for simple prospective and retrospective memory tasks in 5-year-old children.

    PubMed

    Kvavilashvili, Lia; Ford, Ruth M

    2014-11-01

    It is well documented that young children greatly overestimate their performance on tests of retrospective memory (RM), but the current investigation is the first to examine children's prediction accuracy for prospective memory (PM). Three studies were conducted, each testing a different group of 5-year-olds. In Study 1 (N=46), participants were asked to predict their success in a simple event-based PM task (remembering to convey a message to a toy mole if they encountered a particular picture during a picture-naming activity). Before naming the pictures, children listened to either a reminder story or a neutral story. Results showed that children were highly accurate in their PM predictions (78% accuracy) and that the reminder story appeared to benefit PM only in children who predicted they would remember the PM response. In Study 2 (N=80), children showed high PM prediction accuracy (69%) regardless of whether the cue was specific or general and despite typical overoptimism regarding their performance on a 10-item RM task using item-by-item prediction. Study 3 (N=35) showed that children were prone to overestimate RM even when asked about their ability to recall a single item-the mole's unusual name. In light of these findings, we consider possible reasons for children's impressive PM prediction accuracy, including the potential involvement of future thinking in performance predictions and PM. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. Development and Validation of a Food-Associated Olfactory Test (FAOT).

    PubMed

    Denzer-Lippmann, Melanie Yvonne; Beauchamp, Jonathan; Freiherr, Jessica; Thuerauf, Norbert; Kornhuber, Johannes; Buettner, Andrea

    2017-01-01

    Olfactory tests are an important tool in human nutritional research for studying food preferences, yet comprehensive tests dedicated solely to food odors are currently lacking. Therefore, within this study, an innovative food-associated olfactory test (FAOT) system was developed. The FAOT comprises 16 odorant pens that contain representative food odors relating to different macronutrient classes. The test underwent a sensory validation based on identification rate, intensity, hedonic value, and food association scores. The accuracy of the test was further compared to the accuracy of the established Sniffin' Sticks identification test. The identification rates and intensities of this new FAOT were found to be comparable to the Sniffin' Sticks olfactory identification test. The odorant pens were also assessed chemo-analytically and were found to be chemically stable for at least 24 weeks. Overall, this new identification test for use in assessing olfaction in a food-associated context is valid both in terms of its use in sensory perception studies and its chemical stability. The FOAT is particularly suited to examinations of the sense of smell regarding food odors. © The Author 2016. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  18. ACCURACY OF PLASMA FREE METANEPHRINES IN THE DIAGNOSIS OF PHEOCHROMOCYTOMA AND PARAGANGLIOMA: A SYSTEMATIC REVIEW AND META-ANALYSIS.

    PubMed

    Chen, Yan; Xiao, Huangmeng; Zhou, Xieda; Huang, Xiaoyu; Li, Yanbing; Xiao, Haipeng; Cao, Xiaopei

    2017-10-01

    Various studies have validated plasma free metanephrines (MNs) as biomarkers for pheochromocytoma and paraganglioma (PPGL). This meta-analysis aimed to estimate the overall diagnostic accuracy of this biochemical test for PPGL. We searched the PubMed, the Cochrane Library, Web of Science, Embase, Scopus, OvidSP, and ProQuest Dissertations & Theses databases from January 1, 1995 to December 2, 2016 and selected studies written in English that assessed plasma free MNs in the diagnosis of PPGL. Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) was used to evaluate the quality of the included studies. We calculated pooled sensitivities, specificities, positive and negative likelihood ratios, diagnostic odds ratios (DORs) and areas under curve (AUCs) with their 95% confidence intervals (95% CIs). Heterogeneity was assessed by I 2 . To identify the source of heterogeneity, we evaluated the threshold effect and performed a meta-regression. Deeks' funnel plot was selected for investigating any potential publication bias. Although the combination of metanephrine (MN) and normetanephrine (NMN) carried lower specificity (0.94, 95% CI 0.90-0.97) than NMN (0.97, 95% CI 0.92-0.99), NMN was generally more accurate than individual tests, with the highest AUC (0.99, 95% CI 0.97-0.99), DOR (443.35, 95% CI 216.9-906.23), and pooled sensitivity (0.97, 95% CI 0.94-0.98) values. Threshold effect and meta-regression analyses showed that different cut-offs, blood sampling positions, study types and test methods contributed to heterogeneity. This meta-analysis suggested an effective value for combined plasma free MNs for the diagnosis of PPGL, but testing for MNs requires more standardization using tightly regulated studies. AUC = area under curve; CI = confidence interval; DOR = diagnostic odds ratio; EIA = enzyme immunoassay; LC-ECD = liquid chromatography-electrochemical detection; LC-MS/MS = liquid chromatography-tandem mass spectrometry; MN = metanephrine; NMN = normetaneprhine; PPGL = pheochromocytoma and paraganglioma; QUADAS-2 = Quality Assessment of Diagnostic Accuracy Studies 2.

  19. Comparing and Combining Dichotomous and Polytomous Items with SPRT Procedure in Computerized Classification Testing.

    ERIC Educational Resources Information Center

    Lau, C. Allen; Wang, Tianyou

    The purposes of this study were to: (1) extend the sequential probability ratio testing (SPRT) procedure to polytomous item response theory (IRT) models in computerized classification testing (CCT); (2) compare polytomous items with dichotomous items using the SPRT procedure for their accuracy and efficiency; (3) study a direct approach in…

  20. The clinical utility of naturalistic action test in differentiating mild cognitive impairment from early dementia in memory clinic.

    PubMed

    Bruce, Irene; Ntlholang, Ontefetse; Crosby, Lisa; Cunningham, Conal; Lawlor, Brian

    2016-03-01

    This study aimed to examine the validity of the Naturalistic Action Test in differentiating Mild Cognitive Impairment from early dementia compared to clinical diagnosis and ascertain Naturalistic Action Test cut-off points. This was a cross-sectional study of 70 consecutive patients diagnosed with Mild Cognitive Impairment attending the memory clinic in St James's Hospital, Dublin, Ireland. Patients with a diagnosis of Mild Cognitive Impairment who attended for routine annual assessment were asked to participate in the study. The Naturalistic Action Test was carried out after the patient had completed their routine assessment in the clinic. The Area under the Curve, AUC ± SE was 0.808 ± 0.058, p < 0.001 with 95% CI (0.695-0.922). There was concordance in 40 and discrepancy in 30 patients between the NAT and the gold standard consensus diagnosis (PPV 38%, NPV 96%, sensitivity 94%, specificity 46% and accuracy 59%) using cut-off point of ≥14 for normal function on Naturalistic Action Test. The difference was not related to age, sex, level of education or informant. Using the Youden index, we determined a Naturalistic Action Test cut-off score of ≥11 for Mild Cognitive Impairment in our study (PPV 50%, NPV 91%, sensitivity 78%, specificity 73% and accuracy of 74%). There was discrepancy in 18 patients using the new cut-off point (≥11 for Mild Cognitive Impairment vs ≤10 for dementia). The Naturalistic Action Test is a useful tool that can increase diagnostic accuracy in differentiating Mild Cognitive Impairment from early dementia. Copyright © 2015 John Wiley & Sons, Ltd.

  1. Systematic review and meta-analysis: rapid diagnostic tests versus placental histology, microscopy and PCR for malaria in pregnant women.

    PubMed

    Kattenberg, Johanna H; Ochodo, Eleanor A; Boer, Kimberly R; Schallig, Henk Dfh; Mens, Petra F; Leeflang, Mariska Mg

    2011-10-28

    During pregnancy, malaria infection with Plasmodium falciparum or Plasmodium vivax is related to adverse maternal health and poor birth outcomes. Diagnosis of malaria, during pregnancy, is complicated by the absence or low parasite densities in peripheral blood. Diagnostic methods, other than microscopy, are needed for detection of placental malaria. Therefore, the diagnostic accuracy of rapid diagnostic tests (RDTs), detecting antigen, and molecular techniques (PCR), detecting DNA, for the diagnosis of Plasmodium infections in pregnancy was systematically reviewed. MEDLINE, EMBASE and Web of Science were searched for studies assessing the diagnostic accuracy of RDTs, PCR, microscopy of peripheral and placental blood and placental histology for the detection of malaria infection (all species) in pregnant women. The results of 49 studies were analysed in metandi (Stata), of which the majority described P. falciparum infections. Although both placental and peripheral blood microscopy cannot reliably replace histology as a reference standard for placental P. falciparum infection, many studies compared RDTs and PCR to these tests. The proportion of microscopy positives in placental blood (sensitivity) detected by peripheral blood microscopy, RDTs and PCR are respectively 72% [95% CI 62-80], 81% [95% CI 55-93] and 94% [95% CI 86-98]. The proportion of placental blood microscopy negative women that were negative in peripheral blood microscopy, RDTs and PCR (specificity) are 98% [95% CI 95-99], 94% [95% CI 76-99] and 77% [95% CI 71-82]. Based on the current data, it was not possible to determine if the false positives in RDTs and PCR are caused by sequestered parasites in the placenta that are not detected by placental microscopy. The findings suggest that RDTs and PCR may have good performance characteristics to serve as alternatives for the diagnosis of malaria in pregnancy, besides any other limitations and practical considerations concerning the use of these tests. Nevertheless, more studies with placental histology as reference test are urgently required to reliably determine the accuracy of RDTs and PCR for the diagnosis of placental malaria. P. vivax-infections have been neglected in diagnostic test accuracy studies of malaria in pregnancy.

  2. Systematic review and meta-analysis: rapid diagnostic tests versus placental histology, microscopy and PCR for malaria in pregnant women

    PubMed Central

    2011-01-01

    Background During pregnancy, malaria infection with Plasmodium falciparum or Plasmodium vivax is related to adverse maternal health and poor birth outcomes. Diagnosis of malaria, during pregnancy, is complicated by the absence or low parasite densities in peripheral blood. Diagnostic methods, other than microscopy, are needed for detection of placental malaria. Therefore, the diagnostic accuracy of rapid diagnostic tests (RDTs), detecting antigen, and molecular techniques (PCR), detecting DNA, for the diagnosis of Plasmodium infections in pregnancy was systematically reviewed. Methods MEDLINE, EMBASE and Web of Science were searched for studies assessing the diagnostic accuracy of RDTs, PCR, microscopy of peripheral and placental blood and placental histology for the detection of malaria infection (all species) in pregnant women. Results The results of 49 studies were analysed in metandi (Stata), of which the majority described P. falciparum infections. Although both placental and peripheral blood microscopy cannot reliably replace histology as a reference standard for placental P. falciparum infection, many studies compared RDTs and PCR to these tests. The proportion of microscopy positives in placental blood (sensitivity) detected by peripheral blood microscopy, RDTs and PCR are respectively 72% [95% CI 62-80], 81% [95% CI 55-93] and 94% [95% CI 86-98]. The proportion of placental blood microscopy negative women that were negative in peripheral blood microscopy, RDTs and PCR (specificity) are 98% [95% CI 95-99], 94% [95% CI 76-99] and 77% [95% CI 71-82]. Based on the current data, it was not possible to determine if the false positives in RDTs and PCR are caused by sequestered parasites in the placenta that are not detected by placental microscopy. Conclusion The findings suggest that RDTs and PCR may have good performance characteristics to serve as alternatives for the diagnosis of malaria in pregnancy, besides any other limitations and practical considerations concerning the use of these tests. Nevertheless, more studies with placental histology as reference test are urgently required to reliably determine the accuracy of RDTs and PCR for the diagnosis of placental malaria. P. vivax-infections have been neglected in diagnostic test accuracy studies of malaria in pregnancy. PMID:22035448

  3. Noninvasive fetal RhCE genotyping from maternal blood.

    PubMed

    Geifman-Holtzman, O; Grotegut, C A; Gaughan, J P; Holtzman, E J; Floro, C; Hernandez, E

    2009-01-01

    The successful prevention of RhD disease has brought attention to other red blood cells' antigens causing alloimmunisation including RhC/c and RhE/e. Prenatal diagnosis of fetal Rh genotype from maternal blood is in clinical use in Europe but not in the USA. To estimate the collective reported diagnostic accuracy of fetal RhCE genotyping from peripheral maternal blood and compare the results of genotyping when fetal cells and free fetal DNA (FfDNA) are used. English-written literature describing fetal RhCE determination from maternal blood using fetal cells or FfDNA was performed using medical subject headings and text words. The sources included Pubmed (1966-2007), Ovid (1966-2007), CINAHL, The Cochrane Library, ACP Journal Club and OCLC. Key words were prenatal diagnosis, fetal RhCE, fetal DNA in maternal blood and alloimmunisation. A study was considered eligible if it described fetal RhCE type determination using maternal peripheral blood reported in the English literature. Abstracts were excluded. From each study, we determined the number of samples tested, fetal RhCE genotype, the source of the fetal DNA, gestational age, presence of alloimmunisation and confirmation of fetal RhCE type. Exclusions and inclusions were noted. We calculated composite estimates of accuracy using a weighted random effects model. We assessed the papers against an international quality, STARD checklist which is standards for reporting studies of diagnostic accuracy. We identified 20 protocols in six English-written publications reporting fetal RhC/c (seven protocols) and/or E/e (13 protocols) genotyping using DNA obtained from maternal blood for a total of 369 samples. For RhC/c, 176 samples were tested and for RhE/e, 193 samples were tested. Accuracy was determined for each study and for all studies. The combined accuracy of fetal genotype was 96.3% for RhC/c and 98.2% for RhE/e. Only a few samples of the sorted cells were found to be a source for accurate diagnosis, but plasma was consistently the best source of fetal RhCE genotyping in 147/147 (100%) for RhC/c and 168/168 (100%) for RhE/e. The combined accuracy of noninvasive fetal RhC/c or RhE/e determination using maternal peripheral blood is 96.3% and 98.2%, respectively. FfDNA in maternal plasma is a better source for genotyping reported to be 100% correct for both RHCE genotypes. Further studies and reports of accuracy from laboratories performing the tests are required before prenatal determination of fetal RhC/c or RhE/e genotypes from maternal blood can safely replace the current methods used in the management of the RhC/c or RhE alloimmunised pregnancies.

  4. Diagnostic Accuracy of Obstructive Airway Adult Test for Diagnosis of Obstructive Sleep Apnea.

    PubMed

    Gasparini, Giulio; Vicini, Claudio; De Benedetto, Michele; Salamanca, Fabrizio; Sorrenti, Giovanni; Romandini, Mario; Bosi, Marcello; Saponaro, Gianmarco; Foresta, Enrico; Laforì, Andreina; Meccariello, Giuseppe; Bianchi, Alessandro; Toraldo, Domenico Maurizio; Campanini, Aldo; Montevecchi, Filippo; Rizzotto, Grazia; Cervelli, Daniele; Moro, Alessandro; Arigliani, Michele; Gobbi, Riccardo; Pelo, Sandro

    2015-01-01

    The gold standard for the diagnosis of Obstructive Sleep Apnea (OSA) is polysomnography, whose access is however reduced by costs and limited availability, so that additional diagnostic tests are needed. To analyze the diagnostic accuracy of the Obstructive Airway Adult Test (OAAT) compared to polysomnography for the diagnosis of OSA in adult patients. Ninety patients affected by OSA verified with polysomnography (AHI ≥ 5) and ten healthy patients, randomly selected, were included and all were interviewed by one blind examiner with OAAT questions. The Spearman rho, evaluated to measure the correlation between OAAT and polysomnography, was 0.72 (p < 0.01). The area under the ROC curve (95% CI) was the parameter to evaluate the accuracy of the OAAT: it was 0.91 (0.81-1.00) for the diagnosis of OSA (AHI ≥ 5), 0.90 (0.82-0.98) for moderate OSA (AHI ≥ 15), and 0.84 (0.76-0.92) for severe OSA (AHI ≥ 30). The OAAT has shown a high correlation with polysomnography and also a high diagnostic accuracy for the diagnosis of OSA. It has also been shown to be able to discriminate among the different degrees of severity of OSA. Additional large studies aiming to validate this questionnaire as a screening or diagnostic test are needed.

  5. Power calculation for comparing diagnostic accuracies in a multi-reader, multi-test design.

    PubMed

    Kim, Eunhee; Zhang, Zheng; Wang, Youdan; Zeng, Donglin

    2014-12-01

    Receiver operating characteristic (ROC) analysis is widely used to evaluate the performance of diagnostic tests with continuous or ordinal responses. A popular study design for assessing the accuracy of diagnostic tests involves multiple readers interpreting multiple diagnostic test results, called the multi-reader, multi-test design. Although several different approaches to analyzing data from this design exist, few methods have discussed the sample size and power issues. In this article, we develop a power formula to compare the correlated areas under the ROC curves (AUC) in a multi-reader, multi-test design. We present a nonparametric approach to estimate and compare the correlated AUCs by extending DeLong et al.'s (1988, Biometrics 44, 837-845) approach. A power formula is derived based on the asymptotic distribution of the nonparametric AUCs. Simulation studies are conducted to demonstrate the performance of the proposed power formula and an example is provided to illustrate the proposed procedure. © 2014, The International Biometric Society.

  6. Caffeine cravings impair memory and metacognition.

    PubMed

    Palmer, Matthew A; Sauer, James D; Ling, Angus; Riza, Joshua

    2017-10-01

    Cravings for food and other substances can impair cognition. We extended previous research by testing the effects of caffeine cravings on cued-recall and recognition memory tasks, and on the accuracy of judgements of learning (JOLs; predicted future recall) and feeling-of-knowing (FOK; predicted future recognition for items that cannot be recalled). Participants (N = 55) studied word pairs (POND-BOOK) and completed a cued-recall test and a recognition test. Participants made JOLs prior to the cued-recall test and FOK judgements prior to the recognition test. Participants were randomly allocated to a craving or control condition; we manipulated caffeine cravings via a combination of abstinence, cue exposure, and imagery. Cravings impaired memory performance on the cued-recall and recognition tasks. Cravings also impaired resolution (the ability to distinguish items that would be remembered from those that would not) for FOK judgements but not JOLs, and reduced calibration (correspondence between predicted and actual accuracy) for JOLs but not FOK judgements. Additional analysis of the cued-recall data suggested that cravings also reduced participants' ability to monitor the likely accuracy of answers during the cued-recall test. These findings add to prior research demonstrating that memory strength manipulations have systematically different effects on different types of metacognitive judgements.

  7. Analysis of near infrared spectra for age-grading of wild populations of Anopheles gambiae.

    PubMed

    Krajacich, Benjamin J; Meyers, Jacob I; Alout, Haoues; Dabiré, Roch K; Dowell, Floyd E; Foy, Brian D

    2017-11-07

    Understanding the age-structure of mosquito populations, especially malaria vectors such as Anopheles gambiae, is important for assessing the risk of infectious mosquitoes, and how vector control interventions may impact this risk. The use of near-infrared spectroscopy (NIRS) for age-grading has been demonstrated previously on laboratory and semi-field mosquitoes, but to date has not been utilized on wild-caught mosquitoes whose age is externally validated via parity status or parasite infection stage. In this study, we developed regression and classification models using NIRS on datasets of wild An. gambiae (s.l.) reared from larvae collected from the field in Burkina Faso, and two laboratory strains. We compared the accuracy of these models for predicting the ages of wild-caught mosquitoes that had been scored for their parity status as well as for positivity for Plasmodium sporozoites. Regression models utilizing variable selection increased predictive accuracy over the more common full-spectrum partial least squares (PLS) approach for cross-validation of the datasets, validation, and independent test sets. Models produced from datasets that included the greatest range of mosquito samples (i.e. different sampling locations and times) had the highest predictive accuracy on independent testing sets, though overall accuracy on these samples was low. For classification, we found that intramodel accuracy ranged between 73.5-97.0% for grouping of mosquitoes into "early" and "late" age classes, with the highest prediction accuracy found in laboratory colonized mosquitoes. However, this accuracy was decreased on test sets, with the highest classification of an independent set of wild-caught larvae reared to set ages being 69.6%. Variation in NIRS data, likely from dietary, genetic, and other factors limits the accuracy of this technique with wild-caught mosquitoes. Alternative algorithms may help improve prediction accuracy, but care should be taken to either maximize variety in models or minimize confounders.

  8. Comparative difficulty and the strategic regulation of accuracy: the impact of test-list context on monitoring and meta-metacognition.

    PubMed

    Arnold, Michelle M; Prike, Toby

    2015-05-01

    A growing body of research has shown that context manipulations can have little or no impact on accuracy performance, yet still significantly influence metacognitive performance. For example, participants in a test-list context paradigm study one list of words with a medium levels-of-processing task and a second word list with either a shallow or deep task: Recognition for medium words does not differ across conditions, however medium words are significantly more likely to be labeled as "remembered" (vs. merely familiar) if they had been studied with a shallow word list (Bodner & Lindsay, 2003). The goal of the current studies was to extend the test-list context paradigm to strategic regulation (report/withhold recognition test), and broaden it to incorporate different types of stimuli (i.e., face stimuli in place of a medium word list). The paradigm also was modified to include separate answer (studied/new) confidence and decision (report/withhold) confidence ratings at test. Results showed that context did not impact recognition accuracy for faces across the context conditions, however participants were more likely to report (i.e., volunteer) their face responses if they had studied the shallow word list. The results also demonstrated a difference between answer confidence and decision confidence, and the pattern of this difference depended on whether responses were reported or withheld (Experiment 1). Overall, the data are presented as support for the functional account of memory, which views memory states as inferential and attributional rather than static categories. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Quality of Liver and Kidney Function Tests among Public Medical Laboratories in Western Region of Amhara National Regional State of Ethiopia.

    PubMed

    Teka, Abaynesh; Kibatu, Girma

    2012-03-01

    Medical laboratories play essential roles in measurements of substances in body fluids for the purpose of diagnosis, treatment, prevention, and for greater understanding of the disease process. Thus, data generated from have to be reliable for which strict quality control, management and assurance are maintained. The aim of this study is to assess the accuracy and precision of clinical chemistry laboratories in western region of Amhara national regional state of Ethiopia in testing liver and kidney functions. Eight laboratories in hospitals and a Regional Health Research Laboratory Center participated in this study from February to March, 2011. Each participant was requested to measure six specimens for six chemistry tests from two control samples. Three hundred twenty four test results to be reported from all participant laboratories, if all measurements can be made, were designed to be collected and statistically evaluated. None of the study subject laboratories could deliver all the six tests for estimation of both liver and renal functions simultaneously during the study period. Only 213 values from the expected 324 values were reported and about 65 % of the 213 values reported fell outside of the allowable limits of errors for the chemistry tests of the control specimen used. This study finding showed that there were lack of accuracy and precision in chemistry measurements. A regular survey on medical laboratories should be conducted questioning the accuracy and precision of their analyses in order to sustain improvements in the quality of services provided by participating laboratories for the benefit of patients. Laboratory Quality Management Systems appreciate the need for regular quality control and quality assessment schemes in medical laboratories.

  10. Quality and accuracy assessment of nutrition information on the Web for cancer prevention.

    PubMed

    Shahar, Suzana; Shirley, Ng; Noah, Shahrul A

    2013-01-01

    This study aimed to assess the quality and accuracy of nutrition information about cancer prevention available on the Web. The keywords 'nutrition  +  diet  +  cancer  +  prevention' were submitted to the Google search engine. Out of 400 websites evaluated, 100 met the inclusion and exclusion criteria and were selected as the sample for the assessment of quality and accuracy. Overall, 54% of the studied websites had low quality, 48 and 57% had no author's name or information, respectively, 100% were not updated within 1 month during the study period and 86% did not have the Health on the Net seal. When the websites were assessed for readability using the Flesch Reading Ease test, nearly 44% of the websites were categorised as 'quite difficult'. With regard to accuracy, 91% of the websites did not precisely follow the latest WCRF/AICR 2007 recommendation. The quality scores correlated significantly with the accuracy scores (r  =  0.250, p  <  0.05). Professional websites (n  =  22) had the highest mean quality scores, whereas government websites (n  =  2) had the highest mean accuracy scores. The quality of the websites selected in this study was not satisfactory, and there is great concern about the accuracy of the information being disseminated.

  11. Dynamic Accuracy of Inertial Magnetic Sensor Modules

    DTIC Science & Technology

    2016-12-01

    and the cost of the YEI 3-space data-logging sensor was justified. C. PREVIOUS WORK In [7], Jeremy Cookson built a low-cost pendulum with an optical...encoder to test the dynamic accuracy of MARG sensor modules. The pendulum was designed in order to execute dynamic, repeatable tests in a single...3DM-GX1 and 3DM-GX3-25 sensors. In [8], Leslie Landry developed similar repeatable tests and utilized the pendulum to test the dynamic accuracy of

  12. Non-Intrusive Load Monitoring Assessment: Literature Review and Laboratory Protocol

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Butner, R. Scott; Reid, Douglas J.; Hoffman, Michael G.

    2013-07-01

    To evaluate the accuracy of NILM technologies, a literature review was conducted to identify any test protocols or standardized testing approaches currently in use. The literature review indicated that no consistent conventions were currently in place for measuring the accuracy of these technologies. Consequently, PNNL developed a testing protocol and metrics to provide the basis for quantifying and analyzing the accuracy of commercially available NILM technologies. This report discusses the results of the literature review and the proposed test protocol and metrics in more detail.

  13. Accuracy of Bayes and Logistic Regression Subscale Probabilities for Educational and Certification Tests

    ERIC Educational Resources Information Center

    Rudner, Lawrence

    2016-01-01

    In the machine learning literature, it is commonly accepted as fact that as calibration sample sizes increase, Naïve Bayes classifiers initially outperform Logistic Regression classifiers in terms of classification accuracy. Applied to subtests from an on-line final examination and from a highly regarded certification examination, this study shows…

  14. Predicting School Enrollments Using the Modified Regression Technique.

    ERIC Educational Resources Information Center

    Grip, Richard S.; Young, John W.

    This report is based on a study in which a regression model was constructed to increase accuracy in enrollment predictions. A model, known as the Modified Regression Technique (MRT), was used to examine K-12 enrollment over the past 20 years in 2 New Jersey school districts of similar size and ethnicity. To test the model's accuracy, MRT was…

  15. Psychopathy, IQ, and Violence in European American and African American County Jail Inmates

    ERIC Educational Resources Information Center

    Walsh, Zach; Swogger, Marc T.; Kosson, David S.

    2004-01-01

    The accuracy of the prediction of criminal violence may be improved by combining psychopathy with other variables that have been found to predict violence. Research has suggested that assessing intelligence (i.e., IQ) as well as psychopathy improves the accuracy of violence prediction. In the present study, the authors tested this hypothesis by…

  16. Peer-Mediated vs. Individual Writing: Measuring Fluency, Complexity, and Accuracy in Writing

    ERIC Educational Resources Information Center

    Soleimani, Maryam; Modirkhamene, Sima; Sadeghi, Karim

    2017-01-01

    Drawing upon Vygotsky's Sociocultural Theory (SCT), this study aimed at investigating the effect of two writing modes, namely, peer-mediated/collaborative vs. individual writing on measures of fluency, accuracy, and complexity of female EFL learners' writing. Based on an in-house placement test and the First Certificate in English writing paper, a…

  17. Evaluation of transition year Canadian test sites. [Saskatchewan Province

    NASA Technical Reports Server (NTRS)

    Payne, R. W. (Principal Investigator)

    1980-01-01

    The author has identified the following significant results. The spring small grain proportion accuracy in 15 Saskatchewan test sites was found to be comparable to that of the Large Area Crop Inventory Experiment Phase 3 and Transition Year results in the U.S. spring wheat states. Spring small grain labeling accuracy was 94%, and the direct wheat labeling accuracy was 89%, despite the low barley separation accuracy of 30%.

  18. Accuracy of imaging methods for detection of bone tissue invasion in patients with oral squamous cell carcinoma

    PubMed Central

    Uribe, S; Rojas, LA; Rosas, CF

    2013-01-01

    The objective of this review is to evaluate the diagnostic accuracy of imaging methods for detection of mandibular bone tissue invasion by squamous cell carcinoma (SCC). A systematic review was carried out of studies in MEDLINE, SciELO and ScienceDirect, published between 1960 and 2012, in English, Spanish or German, which compared detection of mandibular bone tissue invasion via different imaging tests against a histopathology reference standard. Sensitivity and specificity data were extracted from each study. The outcome measure was diagnostic accuracy. We found 338 articles, of which 5 fulfilled the inclusion criteria. Tests included were: CT (four articles), MRI (four articles), panoramic radiography (one article), positron emission tomography (PET)/CT (one article) and cone beam CT (CBCT) (one article). The quality of articles was low to moderate and the evidence showed that all tests have a high diagnostic accuracy for detection of mandibular bone tissue invasion by SCC, with sensitivity values of 94% (MRI), 91% (CBCT), 83% (CT) and 55% (panoramic radiography), and specificity values of 100% (CT, MRI, CBCT), 97% (PET/CT) and 91.7% (panoramic radiography). Available evidence is scarce and of only low to moderate quality. However, it is consistently shown that current imaging methods give a moderate to high diagnostic accuracy for the detection of mandibular bone tissue invasion by SCC. Recommendations are given for improving the quality of future reports, in particular provision of a detailed description of the patients' conditions, the imaging instrument and both imaging and histopathological invasion criteria. PMID:23420854

  19. Effect of Accreditation on Accuracy of Diagnostic Tests in Medical Laboratories.

    PubMed

    Jang, Mi Ae; Yoon, Young Ahn; Song, Junghan; Kim, Jeong Ho; Min, Won Ki; Lee, Ji Sung; Lee, Yong Wha; Lee, You Kyoung

    2017-05-01

    Medical laboratories play a central role in health care. Many laboratories are taking a more focused and stringent approach to quality system management. In Korea, laboratory standardization efforts undertaken by the Korean Laboratory Accreditation Program (KLAP) and the Korean External Quality Assessment Scheme (KEQAS) may have facilitated an improvement in laboratory performance, but there are no fundamental studies demonstrating that laboratory standardization is effective. We analyzed the results of the KEQAS to identify significant differences between laboratories with or without KLAP and to determine the impact of laboratory standardization on the accuracy of diagnostic tests. We analyzed KEQAS participant data on clinical chemistry tests such as albumin, ALT, AST, and glucose from 2010 to 2013. As a statistical parameter to assess performance bias between laboratories, we compared 4-yr variance index score (VIS) between the two groups with or without KLAP. Compared with the group without KLAP, the group with KLAP exhibited significantly lower geometric means of 4-yr VIS for all clinical chemistry tests (P<0.0001); this difference justified a high level of confidence in standardized services provided by accredited laboratories. Confidence intervals for the mean of each test in the two groups (accredited and non-accredited) did not overlap, suggesting that the means of the groups are significantly different. These results confirmed that practice standardization is strongly associated with the accuracy of test results. Our study emphasizes the necessity of establishing a system for standardization of diagnostic testing. © The Korean Society for Laboratory Medicine

  20. Effect of Accreditation on Accuracy of Diagnostic Tests in Medical Laboratories

    PubMed Central

    Jang, Mi-Ae; Yoon, Young Ahn; Song, Junghan; Kim, Jeong-Ho; Min, Won-Ki; Lee, Ji Sung

    2017-01-01

    Background Medical laboratories play a central role in health care. Many laboratories are taking a more focused and stringent approach to quality system management. In Korea, laboratory standardization efforts undertaken by the Korean Laboratory Accreditation Program (KLAP) and the Korean External Quality Assessment Scheme (KEQAS) may have facilitated an improvement in laboratory performance, but there are no fundamental studies demonstrating that laboratory standardization is effective. We analyzed the results of the KEQAS to identify significant differences between laboratories with or without KLAP and to determine the impact of laboratory standardization on the accuracy of diagnostic tests. Methods We analyzed KEQAS participant data on clinical chemistry tests such as albumin, ALT, AST, and glucose from 2010 to 2013. As a statistical parameter to assess performance bias between laboratories, we compared 4-yr variance index score (VIS) between the two groups with or without KLAP. Results Compared with the group without KLAP, the group with KLAP exhibited significantly lower geometric means of 4-yr VIS for all clinical chemistry tests (P<0.0001); this difference justified a high level of confidence in standardized services provided by accredited laboratories. Confidence intervals for the mean of each test in the two groups (accredited and non-accredited) did not overlap, suggesting that the means of the groups are significantly different. Conclusions These results confirmed that practice standardization is strongly associated with the accuracy of test results. Our study emphasizes the necessity of establishing a system for standardization of diagnostic testing. PMID:28224767

  1. Accuracy of straight leg raise and slump tests in detecting lumbar disc herniation: a pilot study.

    PubMed

    M'kumbuzi, V R P; Ntawukuriryayo, J T; Haminana, J D; Munyandamutsa, J; Nzakizwanimana, E

    2012-01-01

    To determine the accuracy of the Straight Leg Raise (SLR) and slump tests in detecting Lumbar Disc Herniation (LDH). Cross-sectional diagnostic accuracy study. Two referral hospitals in Kigali, Rwanda: King Faisal Hospital and Centre Hospitalier Universitaire de Kigali. All patients aged 18 to 70 who had an MRI and who were experiencing pain in the low back, leg or low back and leg. Closed Magnetic Resonance Imaging (MRI) investigations for each patient as witnessed by a radiologist who read the image were recorded by the first researcher and blinded to other researchers. The SLR and slump tests were performed three times on each patient by independent testers who were blinded to the result of the first test. The test order was randomized for each subject and the two tests were separated by one day wash-out period. Data were analyzed using a 2x2 table to ascertain diagnostic statistics including sensitivity and specificity with 95% confidence intervals. Thirty three from a possible 37 patients mean age 41.58 ± 10 years completed all of the tests. The sensitivity of SLR was greater (0.875; CI: 0.690-0.957) than that of the slump tests (0.800; CI: 0.6087-0.911) (p = 0.01) in detecting LDH. The specificity for SLR was 0.429 (CI: 0.158-0.750) and for slump was 0.714 (CI: 0.359-0.918). Substantial agreement (K = 0.774) was obtained between the SLR and MRI. The SLR was more accurate in detecting LDH. Further validation of this pilot finding is required by studying a larger sample.

  2. Virologic versus cytologic triage of women with equivocal Pap smears: a meta-analysis of the accuracy to detect high-grade intraepithelial neoplasia.

    PubMed

    Arbyn, Marc; Buntinx, Frank; Van Ranst, Marc; Paraskevaidis, Evangelos; Martin-Hirsch, Pierre; Dillner, Joakim

    2004-02-18

    The appropriate management of women with minor cytologic lesions in their cervix is unclear. We performed a meta-analysis to assess the accuracy of human papillomavirus (HPV) DNA testing as an alternative to repeat cytology in women who had equivocal results on a previous Pap smear. Data were extracted from articles published between 1992 and 2002 that contained results of virologic and cytologic testing followed by colposcopically directed biopsy in women with an index smear showing atypical cells of undetermined significance (ASCUS). Fifteen studies were identified in which HPV triage and the histologic outcome (presence or absence of a cervical intraepithelial neoplasia of grade II or worse [CIN2+]) was documented. Nine, seven, and two studies also documented the accuracy of repeat cytology when the cutoff for abnormal cytology was set at a threshold of ASCUS or worse, low-grade squamous intraepithelial lesion (LSIL) or worse, or high-grade squamous intraepithelial lesion (HSIL) or worse, respectively. Random-effects models were used for pooling of accuracy parameters in case of interstudy heterogeneity. Differences in accuracy were assessed by pooling the ratio of the sensitivity (or specificity) of HPV testing to that of repeat cytology. The sensitivity and specificity were 84.4% (95% confidence interval [CI] = 77.6% to 91.1%) and 72.9% (95% CI = 62.5% to 83.3%), respectively, for HPV testing overall and 94.8% (95% CI = 92.7% to 96.9%) and 67.3% (95% CI = 58.2% to 76.4%), respectively, for HPV testing in the eight studies that used the Hybrid Capture II assay. Sensitivity and specificity of repeat cytology at a threshold for abnormal cytology of ASCUS or worse was 81.8% (95% CI = 73.5% to 84.3%) and 57.6% (95% CI = 49.5% to 65.7%), respectively. Repeat cytology that used higher cytologic thresholds yielded substantially lower sensitivity but higher specificity than triage with the Hybrid Capture II assay. The ratio of the sensitivity of the Hybrid Capture II assay to that of repeat cytology at a threshold of ASCUS or worse pooled from the four studies that used both triage tests was 1.16 (95% CI = 1.04 to 1.29). The specificity ratio was not statistically different from unity. The published literature indicates that the Hybrid Capture II assay has improved accuracy (higher sensitivity, similar specificity) than the repeat Pap smear using the threshold of ASCUS for an outcome of CIN2+ among women with equivocal cytologic results. The sensitivity of triage at higher cytologic cutoffs is poor.

  3. An approach for Ewing test selection to support the clinical assessment of cardiac autonomic neuropathy.

    PubMed

    Stranieri, Andrew; Abawajy, Jemal; Kelarev, Andrei; Huda, Shamsul; Chowdhury, Morshed; Jelinek, Herbert F

    2013-07-01

    This article addresses the problem of determining optimal sequences of tests for the clinical assessment of cardiac autonomic neuropathy (CAN). We investigate the accuracy of using only one of the recommended Ewing tests to classify CAN and the additional accuracy obtained by adding the remaining tests of the Ewing battery. This is important as not all five Ewing tests can always be applied in each situation in practice. We used new and unique database of the diabetes screening research initiative project, which is more than ten times larger than the data set used by Ewing in his original investigation of CAN. We utilized decision trees and the optimal decision path finder (ODPF) procedure for identifying optimal sequences of tests. We present experimental results on the accuracy of using each one of the recommended Ewing tests to classify CAN and the additional accuracy that can be achieved by adding the remaining tests of the Ewing battery. We found the best sequences of tests for cost-function equal to the number of tests. The accuracies achieved by the initial segments of the optimal sequences for 2, 3 and 4 categories of CAN are 80.80, 91.33, 93.97 and 94.14, and respectively, 79.86, 89.29, 91.16 and 91.76, and 78.90, 86.21, 88.15 and 88.93. They show significant improvement compared to the sequence considered previously in the literature and the mathematical expectations of the accuracies of a random sequence of tests. The complete outcomes obtained for all subsets of the Ewing features are required for determining optimal sequences of tests for any cost-function with the use of the ODPF procedure. We have also found two most significant additional features that can increase the accuracy when some of the Ewing attributes cannot be obtained. The outcomes obtained can be used to determine the optimal sequences of tests for each individual cost-function by following the ODPF procedure. The results show that the best single Ewing test for diagnosing CAN is the deep breathing heart rate variation test. Optimal sequences found for the cost-function equal to the number of tests guarantee that the best accuracy is achieved after any number of tests and provide an improvement in comparison with the previous ordering of tests or a random sequence. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. 40 CFR 63.4967 - What are the requirements for continuous parameter monitoring system installation, operation, and...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., or to temperature simulation devices. (vi) Conduct a visual inspection of each sensor every quarter... sensor values with electronic signal simulations or via relative accuracy testing. (v) Perform accuracy... values with electronic signal simulations or with values obtained via relative accuracy testing. (vi...

  5. 40 CFR 63.4967 - What are the requirements for continuous parameter monitoring system installation, operation, and...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., or to temperature simulation devices. (vi) Conduct a visual inspection of each sensor every quarter... sensor values with electronic signal simulations or via relative accuracy testing. (v) Perform accuracy... values with electronic signal simulations or with values obtained via relative accuracy testing. (vi...

  6. 40 CFR 63.4967 - What are the requirements for continuous parameter monitoring system installation, operation, and...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., or to temperature simulation devices. (vi) Conduct a visual inspection of each sensor every quarter... sensor values with electronic signal simulations or via relative accuracy testing. (v) Perform accuracy... values with electronic signal simulations or with values obtained via relative accuracy testing. (vi...

  7. The microcomputer scientific software series 4: testing prediction accuracy.

    Treesearch

    H. Michael Rauscher

    1986-01-01

    A computer program, ATEST, is described in this combination user's guide / programmer's manual. ATEST provides users with an efficient and convenient tool to test the accuracy of predictors. As input ATEST requires observed-predicted data pairs. The output reports the two components of accuracy, bias and precision.

  8. Accuracy of cystatin C for the detection of abnormal renal function in children undergoing chemotherapy for malignancy: a systematic review using individual patient data.

    PubMed

    Whiting, Penny; Birnie, Kate; Sterne, Jonathan A C; Jameson, Catherine; Skinner, Rod; Phillips, Bob

    2018-05-01

    We conducted a systematic review and individual patient data (IPD) meta-analysis to examine the utility of cystatin C for evaluation of glomerular function in children with cancer. Eligible studies evaluated the accuracy of cystatin C for detecting poor renal function in children undergoing chemotherapy. Study quality was assessed using QUADAS-2. Authors of four studies shared IPD. We calculated the correlation between log cystatin C and GFR stratified by study and measure of cystatin C. We dichotomized the reference standard at GFR 80 ml/min/1.73m 2 and stratified cystatin C at 1 mg/l, to calculate sensitivity and specificity in each study and according to age group (0-4, 5-12, and ≥ 13 years). In sensitivity analyses, we investigated different GFR and cystatin C cut points. We used logistic regression to estimate the association of impaired renal function with log cystatin C and quantified diagnostic accuracy using the area under the ROC curve (AUC). Six studies, which used different test and reference standard thresholds, suggested that cystatin C has the potential to monitor renal function in children undergoing chemotherapy for malignancy. IPD data (504 samples, 209 children) showed that cystatin C has poor sensitivity (63%) and moderate specificity (89%), although use of a GFR cut point of < 60 ml/min/1.73m 2 (data only available from two of the studies) estimated sensitivity to be 92% and specificity 81.3%. The AUC for the combined data set was 0.890 (95% CI 0.826, 0.951). Diagnostic accuracy appeared to decrease with age. Cystatin C has better diagnostic accuracy than creatinine as a test for glomerular dysfunction in young people undergoing treatment for cancer. Diagnostic accuracy is not sufficient for it to replace current reference standards for predicting clinically relevant impairments that may alter dosing of important nephrotoxic agents.

  9. Part-of-speech tagging for clinical text: wall or bridge between institutions?

    PubMed Central

    Fan, Jung-wei; Prasad, Rashmi; Yabut, Rommel M.; Loomis, Richard M.; Zisook, Daniel S.; Mattison, John E.; Huang, Yang

    2011-01-01

    Part-of-speech (POS) tagging is a fundamental step required by various NLP systems. The training of a POS tagger relies on sufficient quality annotations. However, the annotation process is both knowledge-intensive and time-consuming in the clinical domain. A promising solution appears to be for institutions to share their annotation efforts, and yet there is little research on associated issues. We performed experiments to understand how POS tagging performance would be affected by using a pre-trained tagger versus raw training data across different institutions. We manually annotated a set of clinical notes at Kaiser Permanente Southern California (KPSC) and a set from the University of Pittsburg Medical Center (UPMC), and trained/tested POS taggers with intra- and inter-institution settings. The cTAKES POS tagger was also included in the comparison to represent a tagger partially trained from the notes of a third institution, Mayo Clinic at Rochester. Intra-institution 5-fold cross-validation estimated an accuracy of 0.953 and 0.945 on the KPSC and UPMC notes respectively. Trained purely on KPSC notes, the accuracy was 0.897 when tested on UPMC notes. Trained purely on UPMC notes, the accuracy was 0.904 when tested on KPSC notes. Applying the cTAKES tagger pre-trained with Mayo Clinic’s notes, the accuracy was 0.881 on KPSC notes and 0.883 on UPMC notes. After adding UPMC annotations to KPSC training data, the average accuracy on tested KPSC notes increased to 0.965. After adding KPSC annotations to UPMC training data, the average accuracy on tested UPMC notes increased to 0.953. The results indicated: first, the performance of pre-trained POS taggers dropped about 5% when applied directly across the institutions; second, mixing annotations from another institution following the same guideline increased tagging accuracy for about 1%. Our findings suggest that institutions can benefit more from sharing raw annotations but less from sharing pre-trained models for the POS tagging task. We believe the study could also provide general insights on cross-institution data sharing for other types of NLP tasks. PMID:22195091

  10. Part-of-speech tagging for clinical text: wall or bridge between institutions?

    PubMed

    Fan, Jung-wei; Prasad, Rashmi; Yabut, Rommel M; Loomis, Richard M; Zisook, Daniel S; Mattison, John E; Huang, Yang

    2011-01-01

    Part-of-speech (POS) tagging is a fundamental step required by various NLP systems. The training of a POS tagger relies on sufficient quality annotations. However, the annotation process is both knowledge-intensive and time-consuming in the clinical domain. A promising solution appears to be for institutions to share their annotation efforts, and yet there is little research on associated issues. We performed experiments to understand how POS tagging performance would be affected by using a pre-trained tagger versus raw training data across different institutions. We manually annotated a set of clinical notes at Kaiser Permanente Southern California (KPSC) and a set from the University of Pittsburg Medical Center (UPMC), and trained/tested POS taggers with intra- and inter-institution settings. The cTAKES POS tagger was also included in the comparison to represent a tagger partially trained from the notes of a third institution, Mayo Clinic at Rochester. Intra-institution 5-fold cross-validation estimated an accuracy of 0.953 and 0.945 on the KPSC and UPMC notes respectively. Trained purely on KPSC notes, the accuracy was 0.897 when tested on UPMC notes. Trained purely on UPMC notes, the accuracy was 0.904 when tested on KPSC notes. Applying the cTAKES tagger pre-trained with Mayo Clinic's notes, the accuracy was 0.881 on KPSC notes and 0.883 on UPMC notes. After adding UPMC annotations to KPSC training data, the average accuracy on tested KPSC notes increased to 0.965. After adding KPSC annotations to UPMC training data, the average accuracy on tested UPMC notes increased to 0.953. The results indicated: first, the performance of pre-trained POS taggers dropped about 5% when applied directly across the institutions; second, mixing annotations from another institution following the same guideline increased tagging accuracy for about 1%. Our findings suggest that institutions can benefit more from sharing raw annotations but less from sharing pre-trained models for the POS tagging task. We believe the study could also provide general insights on cross-institution data sharing for other types of NLP tasks.

  11. Diagnostic Accuracy of Memory Measures in Alzheimer's Dementia and Mild Cognitive Impairment: a Systematic Review and Meta-Analysis.

    PubMed

    Weissberger, Gali H; Strong, Jessica V; Stefanidis, Kayla B; Summers, Mathew J; Bondi, Mark W; Stricker, Nikki H

    2017-12-01

    With an increasing focus on biomarkers in dementia research, illustrating the role of neuropsychological assessment in detecting mild cognitive impairment (MCI) and Alzheimer's dementia (AD) is important. This systematic review and meta-analysis, conducted in accordance with PRISMA (Preferred Reporting Items for Systematic reviews and Meta-Analyses) standards, summarizes the sensitivity and specificity of memory measures in individuals with MCI and AD. Both meta-analytic and qualitative examination of AD versus healthy control (HC) studies (n = 47) revealed generally high sensitivity and specificity (≥ 80% for AD comparisons) for measures of immediate (sensitivity = 87%, specificity = 88%) and delayed memory (sensitivity = 89%, specificity = 89%), especially those involving word-list recall. Examination of MCI versus HC studies (n = 38) revealed generally lower diagnostic accuracy for both immediate (sensitivity = 72%, specificity = 81%) and delayed memory (sensitivity = 75%, specificity = 81%). Measures that differentiated AD from other conditions (n = 10 studies) yielded mixed results, with generally high sensitivity in the context of low or variable specificity. Results confirm that memory measures have high diagnostic accuracy for identification of AD, are promising but require further refinement for identification of MCI, and provide support for ongoing investigation of neuropsychological assessment as a cognitive biomarker of preclinical AD. Emphasizing diagnostic test accuracy statistics over null hypothesis testing in future studies will promote the ongoing use of neuropsychological tests as Alzheimer's disease research and clinical criteria increasingly rely upon cerebrospinal fluid (CSF) and neuroimaging biomarkers.

  12. Accuracy of the Yamax CW-701 Pedometer for measuring steps in controlled and free-living conditions

    PubMed Central

    Coffman, Maren J; Reeve, Charlie L; Butler, Shannon; Keeling, Maiya; Talbot, Laura A

    2016-01-01

    Objective The Yamax Digi-Walker CW-701 (Yamax CW-701) is a low-cost pedometer that includes a 7-day memory, a 2-week cumulative memory, and automatically resets to zero at midnight. To date, the accuracy of the Yamax CW-701 has not been determined. The purpose of this study was to assess the accuracy of steps recorded by the Yamax CW-701 pedometer compared with actual steps and two other devices. Methods The study was conducted in a campus-based lab and in free-living settings with 22 students, faculty, and staff at a mid-sized university in the Southeastern US. While wearing a Yamax CW-701, Yamax Digi-Walker SW-200, and an ActiGraph GTX3 accelerometer, participants engaged in activities at variable speeds and conditions. To assess accuracy of each device, steps recorded were compared with actual step counts. Statistical tests included paired sample t-tests, percent accuracy, intraclass correlation coefficient, and Bland–Altman plots. Results The Yamax CW-701 demonstrated reliability and concurrent validity during walking at a fast pace and walking on a track, and in free-living conditions. Decreased accuracy was noted walking at a slow pace. Conclusions These findings are consistent with prior research. With most pedometers and accelerometers, adequate force and intensity must be present for a step to register. The Yamax CW-701 is accurate in recording steps taken while walking at a fast pace and in free-living settings. PMID:29942555

  13. Accuracy of the Yamax CW-701 Pedometer for measuring steps in controlled and free-living conditions.

    PubMed

    Coffman, Maren J; Reeve, Charlie L; Butler, Shannon; Keeling, Maiya; Talbot, Laura A

    2016-01-01

    The Yamax Digi-Walker CW-701 (Yamax CW-701) is a low-cost pedometer that includes a 7-day memory, a 2-week cumulative memory, and automatically resets to zero at midnight. To date, the accuracy of the Yamax CW-701 has not been determined. The purpose of this study was to assess the accuracy of steps recorded by the Yamax CW-701 pedometer compared with actual steps and two other devices. The study was conducted in a campus-based lab and in free-living settings with 22 students, faculty, and staff at a mid-sized university in the Southeastern US. While wearing a Yamax CW-701, Yamax Digi-Walker SW-200, and an ActiGraph GTX3 accelerometer, participants engaged in activities at variable speeds and conditions. To assess accuracy of each device, steps recorded were compared with actual step counts. Statistical tests included paired sample t -tests, percent accuracy, intraclass correlation coefficient, and Bland-Altman plots. The Yamax CW-701 demonstrated reliability and concurrent validity during walking at a fast pace and walking on a track, and in free-living conditions. Decreased accuracy was noted walking at a slow pace. These findings are consistent with prior research. With most pedometers and accelerometers, adequate force and intensity must be present for a step to register. The Yamax CW-701 is accurate in recording steps taken while walking at a fast pace and in free-living settings.

  14. Fundus autofluorescence imaging: systematic review of test accuracy for the diagnosis and monitoring of retinal conditions.

    PubMed

    Frampton, G K; Kalita, N; Payne, L; Colquitt, J L; Loveman, E; Downes, S M; Lotery, A J

    2017-07-01

    We conducted a systematic review of the accuracy of fundus autofluorescence (FAF) imaging for diagnosing and monitoring retinal conditions. Searches in November 2014 identified English language references. Sources included MEDLINE, EMBASE, the Cochrane Library, Web of Science, and MEDION databases; reference lists of retrieved studies; and internet pages of relevant organisations, meetings, and trial registries. For inclusion, studies had to report FAF imaging accuracy quantitatively. Studies were critically appraised using QUADAS risk of bias criteria. Two reviewers conducted all review steps. From 2240 unique references identified, eight primary research studies met the inclusion criteria. These investigated diagnostic accuracy of FAF imaging for choroidal neovascularisation (one study), reticular pseudodrusen (three studies), cystoid macular oedema (two studies), and diabetic macular oedema (two studies). Diagnostic sensitivity of FAF imaging ranged from 32 to 100% and specificity from 34 to 100%. However, owing to methodological limitations, including high and/or unclear risks of bias, none of these studies provides conclusive evidence of the diagnostic accuracy of FAF imaging. Study heterogeneity precluded meta-analysis. In most studies, the patient spectrum was not reflective of those who would present in clinical practice and no studies adequately reported whether FAF images were interpreted consistently. No studies of monitoring accuracy were identified. An update in October 2016, based on MEDLINE and internet searches, identified four new studies but did not alter our conclusions. Robust quantitative evidence on the accuracy of FAF imaging and how FAF images are interpreted is lacking. We provide recommendations to address this.

  15. Photoplethysmography using a smartphone application for assessment of ulnar artery patency: a randomized clinical trial

    PubMed Central

    Di Santo, Pietro; Harnett, David T.; Simard, Trevor; Ramirez, F. Daniel; Pourdjabbar, Ali; Yousef, Altayyeb; Moreland, Robert; Bernick, Jordan; Wells, George; Dick, Alexander; Le May, Michel; Labinaz, Marino; So, Derek; Motazedian, Pouya; Jung, Richard G.; Chandrasekhar, Jaya; Mehran, Roxana; Chong, Aun-Yeong

    2018-01-01

    BACKGROUND: Radial artery access is commonly performed for coronary angiography and invasive hemodynamic monitoring. Despite limitations in diagnostic accuracy, the modified Allen test (manual occlusion of radial and ulnar arteries followed by release of the latter and assessment of palmar blush) is used routinely to evaluate the collateral circulation to the hand and, therefore, to determine patient eligibility for radial artery access. We sought to evaluate whether a smartphone application may provide a superior alternative to the modified Allen test. METHODS: We compared the modified Allen test with a smartphone heart rate–monitoring application (photoplethysmography readings detected using a smartphone camera lens placed on the patient’s index finger) in patients undergoing a planned cardiac catheterization. Test order was randomly assigned in a 1:1 fashion. All patients then underwent conventional plethysmography of the index finger, followed by Doppler ultrasonography of the radial and ulnar arteries (the diagnostic standard). The primary outcome was diagnostic accuracy of the heart rate–monitoring application. RESULTS: Among 438 patients who were included in the study, we found that the heart rate–monitoring application had a superior diagnostic accuracy compared with the modified Allen test (91.8% v. 81.7%, p = 0.002), attributable to its greater specificity (93.0% v. 82.8%, p = 0.001). We also found that this application had greater diagnostic accuracy for assessment of radial or ulnar artery patency in the ipsilateral and contralateral wrist (94.0% v. 84.0%, p < 0.001). INTERPRETATION: A smartphone application used at the bedside was diagnostically superior to traditional physical examination for confirming ulnar patency before radial artery access. This study highlights the potential for smartphone-based diagnostics to aid in clinical decision-making at the patient’s bedside. Trial registration: Clinicaltrials.gov, no. NCT02519491. PMID:29615421

  16. Use of Serial Quantitative PCR of the vapA Gene of Rhodococcus equi in Feces for Early Detection of R. equi Pneumonia in Foals.

    PubMed

    Madrigal, R G; Shaw, S D; Witkowski, L A; Sisson, B E; Blodgett, G P; Chaffin, M K; Cohen, N D

    2016-01-01

    Current screening tests for Rhodococcus equi pneumonia in foals lack adequate accuracy for clinical use. Real-time, quantitative PCR (qPCR) for virulent R. equi in feces has not been systematically evaluated as a screening test. The objective of this study was to evaluate the accuracy of qPCR for vapA in serially collected fecal samples as a screening test for R. equi pneumonia in foals. One hundred and twenty-five foals born in 2011 at a ranch in Texas. Fecal samples were collected concurrently with thoracic ultrasonography (TUS) screening examinations at ages 3, 5, and 7 weeks. Affected (pneumonic) foals (n = 25) were matched by age and date-of-birth to unaffected (n = 25) and subclinical (ie, having thoracic TUS lesions but no clinical signs of pneumonia) foals (n = 75). DNA was extracted from feces using commercial kits and concentration of virulent R. equi in feces was determined by qPCR. Subsequently affected foals had significantly greater concentrations of vapA in feces than foals that did not develop pneumonia (unaffected and subclinical foals) at 5 and 7 weeks of age. Accuracy of fecal qPCR, however, was poor as a screening test to differentiate foals that would develop clinical signs of pneumonia from those that would remain free of clinical signs (including foals with subclinical pulmonary lesions attributed to R. equi) using receiver operating characteristic (ROC) methods. In the population studied, serial qPCR on feces lacked adequate accuracy as a screening test for clinical R. equi foal pneumonia. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  17. Photoplethysmography using a smartphone application for assessment of ulnar artery patency: a randomized clinical trial.

    PubMed

    Di Santo, Pietro; Harnett, David T; Simard, Trevor; Ramirez, F Daniel; Pourdjabbar, Ali; Yousef, Altayyeb; Moreland, Robert; Bernick, Jordan; Wells, George; Dick, Alexander; Le May, Michel; Labinaz, Marino; So, Derek; Motazedian, Pouya; Jung, Richard G; Chandrasekhar, Jaya; Mehran, Roxana; Chong, Aun-Yeong; Hibbert, Benjamin

    2018-04-03

    Radial artery access is commonly performed for coronary angiography and invasive hemodynamic monitoring. Despite limitations in diagnostic accuracy, the modified Allen test (manual occlusion of radial and ulnar arteries followed by release of the latter and assessment of palmar blush) is used routinely to evaluate the collateral circulation to the hand and, therefore, to determine patient eligibility for radial artery access. We sought to evaluate whether a smartphone application may provide a superior alternative to the modified Allen test. We compared the modified Allen test with a smartphone heart rate-monitoring application (photoplethysmography readings detected using a smartphone camera lens placed on the patient's index finger) in patients undergoing a planned cardiac catheterization. Test order was randomly assigned in a 1:1 fashion. All patients then underwent conventional plethysmography of the index finger, followed by Doppler ultrasonography of the radial and ulnar arteries (the diagnostic standard). The primary outcome was diagnostic accuracy of the heart rate-monitoring application. Among 438 patients who were included in the study, we found that the heart rate-monitoring application had a superior diagnostic accuracy compared with the modified Allen test (91.8% v. 81.7%, p = 0.002), attributable to its greater specificity (93.0% v. 82.8%, p = 0.001). We also found that this application had greater diagnostic accuracy for assessment of radial or ulnar artery patency in the ipsilateral and contralateral wrist (94.0% v. 84.0%, p < 0.001). A smartphone application used at the bedside was diagnostically superior to traditional physical examination for confirming ulnar patency before radial artery access. This study highlights the potential for smartphone-based diagnostics to aid in clinical decision-making at the patient's bedside. Trial registration: Clinicaltrials.gov, no. NCT02519491. © 2018 Joule Inc. or its licensors.

  18. Individual differences in preschoolers' emotion content memory: the role of emotion knowledge.

    PubMed

    Channell, Marie Moore; Barth, Joan M

    2013-07-01

    This study examined the relation between preschool children's emotion knowledge and their ability to recall emotionally salient information. In total, 42 participants (ages 35-65months) viewed a brief video in which a child played with different toys and expressed one of four basic emotions (happy, sad, angry, or afraid) or a neutral expression in each of 10 vignettes. Children were tested on memory accuracy from the vignettes, and their emotion knowledge was also measured. Results indicated that preschoolers' emotion knowledge was significantly related to memory accuracy for emotion information above and beyond the effect of age or receptive language skills. Tests of a mediation model revealed that emotion knowledge fully mediated the effect of age (or general developmental level) on memory accuracy. Copyright © 2013 Elsevier Inc. All rights reserved.

  19. Sensitivity and specificity of the AdenoPlus point-of-care system in detecting adenovirus in conjunctivitis patients at an ophthalmic emergency department: a diagnostic accuracy study.

    PubMed

    Kam, K Y Ronald; Ong, Hon Shing; Bunce, Catey; Ogunbowale, Lola; Verma, Seema

    2015-09-01

    To estimate the diagnostic accuracy (sensitivity and specificity) of the AdenoPlus point-of-care adenoviral test compared to PCR in an ophthalmic accident and emergency service. These findings were compared with those of a previous study. This was a prospective diagnostic accuracy study on 121 patients presenting to an emergency eye unit with a clinical picture of acute adenoviral conjunctivitis. AdenoPlus testing was carried out on one eye of each patient and a PCR analysis was also performed on a swab taken from the same eye. AdenoPlus and PCR results were interpreted by masked personnel. Sensitivity and specificity for the AdenoPlus test were calculated using PCR results as the reference standard. 121 patients were enrolled and 109 met the inclusion criteria. 43 patients (39.4%) tested positive for adenovirus by PCR analysis. The sensitivity of the AdenoPlus swab in detecting adenovirus was 39.5% (17/43, 95% CI 26% to 54%) and specificity was 95.5% (63/66, 95% CI 87% to 98%) compared to PCR. The AdenoPlus test has a high specificity for diagnosing adenoviral conjunctivitis, but in this clinical setting, we could not reproduce the high sensitivity that has been previously published. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  20. Water-loss (intracellular) dehydration assessed using urinary tests: how well do they work? Diagnostic accuracy in older people.

    PubMed

    Hooper, Lee; Bunn, Diane K; Abdelhamid, Asmaa; Gillings, Rachel; Jennings, Amy; Maas, Katie; Millar, Sophie; Twomlow, Elizabeth; Hunter, Paul R; Shepstone, Lee; Potter, John F; Fairweather-Tait, Susan J

    2016-07-01

    Water-loss dehydration (hypertonic, hyperosmotic, or intracellular dehydration) is due to insufficient fluid intake and is distinct from hypovolemia due to excess fluid losses. Water-loss dehydration is associated with poor health outcomes such as disability and mortality in older people. Urine specific gravity (USG), urine color, and urine osmolality have been widely advocated for screening for dehydration in older adults. We assessed the diagnostic accuracy of urinary measures to screen for water-loss dehydration in older people. This was a diagnostic accuracy study of people aged ≥65 y taking part in the DRIE (Dehydration Recognition In our Elders; living in long-term care) or NU-AGE (Dietary Strategies for Healthy Ageing in Europe; living in the community) studies. The reference standard was serum osmolality, and index tests included USG, urine color, urine osmolality, urine cloudiness, additional dipstick measures, ability to provide a urine sample, and the volume of a random urine sample. Minimum useful diagnostic accuracy was set at sensitivity and specificity ≥70% or a receiver operating characteristic plot area under the curve ≥0.70. DRIE participants (women: 67%; mean age: 86 y; n = 162) had more limited cognitive and functional abilities than did NU-AGE participants (women: 64%; mean age: 70 y; n = 151). Nineteen percent of DRIE participants and 22% of NU-AGE participants were dehydrated (serum osmolality >300 mOsm/kg). Neither USG nor any other potential urinary tests were usefully diagnostic for water-loss dehydration. Although USG, urine color, and urinary osmolality have been widely advocated for screening for dehydration in older adults, we show, in the largest study to date to our knowledge, that their diagnostic accuracy is too low to be useful, and these measures should not be used to indicate hydration status in older people (either alone or as part of a wider tranche of tests). There is a need to develop simple, inexpensive, and noninvasive tools for the assessment of dehydration in older people. The DRIE study was registered at www.researchregister.org.uk as 122273. The NU-AGE trial was registered at clinicialtrials.gov as NCT01754012. © 2016 American Society for Nutrition.

  1. Limited diagnostic accuracy of magnetic resonance imaging and clinical tests for detecting partial-thickness tears of the rotator cuff.

    PubMed

    Brockmeyer, Matthias; Schmitt, Cornelia; Haupert, Alexander; Kohn, Dieter; Lorbach, Olaf

    2017-12-01

    The reliable diagnosis of partial-thickness tears of the rotator cuff is still elusive in clinical practise. Therefore, the purpose of the study was to determine the diagnostic accuracy of MR imaging and clinical tests for detecting partial-thickness tears of the rotator cuff as well as the combination of these parameters. 334 consecutive shoulder arthroscopies for rotator cuff pathologies performed during the time period between 2010 and 2012 were analyzed retrospectively for the findings of common clinical signs for rotator cuff lesions and preoperative MR imaging. These were compared with the intraoperative arthroscopic findings as "gold standard". The reports of the MR imaging were evaluated with regard to the integrity of the rotator cuff. The Ellman Classification was used to define partial-thickness tears of the rotator cuff in accordance with the arthroscopic findings. Descriptive statistics, sensitivity, specificity, positive and negative predictive value were calculated. MR imaging showed 80 partial-thickness and 70 full-thickness tears of the rotator cuff. The arthroscopic examination confirmed 64 partial-thickness tears of which 52 needed debridement or refixation of the rotator cuff. Sensitivity for MR imaging to identify partial-thickness tears was 51.6%, specificity 77.2%, positive predictive value 41.3% and negative predictive value 83.7%. For the Jobe-test, sensitivity was 64.1%, specificity 43.2%, positive predictive value 25.9% and negative predictive value 79.5%. Sensitivity for the Impingement-sign was 76.7%, specificity 46.6%, positive predictive value 30.8% and negative predictive value 86.5%. For the combination of MR imaging, Jobe-test and Impingement-sign sensitivity was 46.9%, specificity 85.4%, positive predictive value 50% and negative predictive value 83.8%. The diagnostic accuracy of MR imaging and clinical tests (Jobe-test and Impingement-sign) alone is limited for detecting partial-thickness tears of the rotator cuff. Additionally, the combination of MR imaging and clinical tests does not improve diagnostic accuracy. Level II, Diagnostic study.

  2. Picture Superiority Doubly Dissociates the ERP Correlates of Recollection and Familiarity

    ERIC Educational Resources Information Center

    Curran, Tim; Doyle, Jeanne

    2011-01-01

    Two experiments investigated the processes underlying the picture superiority effect on recognition memory. Studied pictures were associated with higher accuracy than studied words, regardless of whether test stimuli were words (Experiment 1) or pictures (Experiment 2). Event-related brain potentials (ERPs) recorded during test suggested that the…

  3. Testing Promotes Eyewitness Accuracy with a Warning: Implications for Retrieval Enhanced Suggestibility

    ERIC Educational Resources Information Center

    Thomas, Ayanna K.; Bulevich, John B.; Chan, Jason C. K.

    2010-01-01

    Numerous studies have demonstrated that repeated retrieval boosts later retention. However, recent research has shown that testing can increase eyewitness susceptibility to misleading post-event information (e.g., Chan, Thomas, & Bulevich, 2009). The present study examines the effects of warning on this counterintuitive finding. In two…

  4. Best Design for Multidimensional Computerized Adaptive Testing with the Bifactor Model

    ERIC Educational Resources Information Center

    Seo, Dong Gi; Weiss, David J.

    2015-01-01

    Most computerized adaptive tests (CATs) have been studied using the framework of unidimensional item response theory. However, many psychological variables are multidimensional and might benefit from using a multidimensional approach to CATs. This study investigated the accuracy, fidelity, and efficiency of a fully multidimensional CAT algorithm…

  5. Performance Evaluation of sUAS Equipped with Velodyne HDL-32E LiDAR Sensor

    NASA Astrophysics Data System (ADS)

    Jozkow, G.; Wieczorek, P.; Karpina, M.; Walicka, A.; Borkowski, A.

    2017-08-01

    The Velodyne HDL-32E laser scanner is used more frequently as main mapping sensor in small commercial UASs. However, there is still little information about the actual accuracy of point clouds collected with such UASs. This work evaluates empirically the accuracy of the point cloud collected with such UAS. Accuracy assessment was conducted in four aspects: impact of sensors on theoretical point cloud accuracy, trajectory reconstruction quality, and internal and absolute point cloud accuracies. Theoretical point cloud accuracy was evaluated by calculating 3D position error knowing errors of used sensors. The quality of trajectory reconstruction was assessed by comparing position and attitude differences from forward and reverse EKF solution. Internal and absolute accuracies were evaluated by fitting planes to 8 point cloud samples extracted for planar surfaces. In addition, the absolute accuracy was also determined by calculating point 3D distances between LiDAR UAS and reference TLS point clouds. Test data consisted of point clouds collected in two separate flights performed over the same area. Executed experiments showed that in tested UAS, the trajectory reconstruction, especially attitude, has significant impact on point cloud accuracy. Estimated absolute accuracy of point clouds collected during both test flights was better than 10 cm, thus investigated UAS fits mapping-grade category.

  6. False memory in aging: effects of emotional valence on word recognition accuracy.

    PubMed

    Piguet, Olivier; Connally, Emily; Krendl, Anne C; Huot, Jessica R; Corkin, Suzanne

    2008-06-01

    Memory is susceptible to distortions. Valence and increasing age are variables known to affect memory accuracy and may increase false alarm production. Interaction between these variables and their impact on false memory was investigated in 36 young (18-28 years) and 36 older (61-83 years) healthy adults. At study, participants viewed lists of neutral words orthographically related to negative, neutral, or positive critical lures (not presented). Memory for these words was subsequently tested with a remember-know procedure. At test, items included the words seen at study and their associated critical lures, as well as sets of orthographically related neutral words not seen at study and their associated unstudied lures. Positive valence was shown to have two opposite effects on older adults' discrimination of the lures: It improved correct rejection of unstudied lures but increased false memory for critical lures (i.e., lures associated with words studied previously). Thus, increased salience triggered by positive valence may disrupt memory accuracy in older adults when discriminating among similar events. These findings likely reflect a source memory deficit due to decreased efficiency in cognitive control processes with aging.

  7. Accuracy of fundus autofluorescence imaging for the diagnosis and monitoring of retinal conditions: a systematic review.

    PubMed

    Frampton, Geoff K; Kalita, Neelam; Payne, Liz; Colquitt, Jill; Loveman, Emma

    2016-04-01

    Natural fluorescence in the eye may be increased or decreased by diseases that affect the retina. Imaging methods based on confocal scanning laser ophthalmoscopy (cSLO) can detect this 'fundus autofluorescence' (FAF) by illuminating the retina using a specific light 'excitation wavelength'. FAF imaging could assist the diagnosis or monitoring of retinal conditions. However, the accuracy of the method for diagnosis or monitoring is unclear. To conduct a systematic review to determine the accuracy of FAF imaging using cSLO for the diagnosis or monitoring of retinal conditions, including monitoring of response to therapy. Electronic bibliographic databases; scrutiny of reference lists of included studies and relevant systematic reviews; and searches of internet pages of relevant organisations, meetings and trial registries. Databases included MEDLINE, EMBASE, The Cochrane Library, Web of Science and the Medion database of diagnostic accuracy studies. Searches covered 1990 to November 2014 and were limited to the English language. References were screened for relevance using prespecified inclusion criteria to capture a broad range of retinal conditions. Two reviewers assessed titles and abstracts independently. Full-text versions of relevant records were retrieved and screened by one reviewer and checked by a second. Data were extracted and critically appraised using the Quality Assessment of Diagnostic Accuracy Studies criteria (QUADAS) for assessing risk of bias in test accuracy studies by one reviewer and checked by a second. At all stages any reviewer disagreement was resolved through discussion or arbitration by a third reviewer. Eight primary research studies have investigated the diagnostic accuracy of FAF imaging in retinal conditions: choroidal neovascularisation (one study), reticular pseudodrusen (three studies), cystoid macular oedema (two studies) and diabetic macular oedema (two studies). Sensitivity of FAF imaging using an excitation wavelength of 488 nm was generally high (range 81-100%), but was lower (55% and 32%) in two studies using longer excitation wavelengths (514 nm and 790 nm, respectively). Specificity ranged from 34% to 100%. However, owing to limitations of the data, none of the studies provide conclusive evidence of the diagnostic accuracy of FAF imaging. No studies on the accuracy of FAF imaging for monitoring the progression of retinal conditions or response to therapy were identified. Owing to study heterogeneity, pooling of diagnostic outcomes in meta-analysis was not conducted. All included studies had high risk of bias. In most studies the patient spectrum was not reflective of those who would present in clinical practice and no studies adequately reported how FAF images were interpreted. Although already in use in clinical practice, it is unclear whether or not FAF imaging is accurate, and whether or not it is applied and interpreted consistently for the diagnosis and/or monitoring of retinal conditions. Well-designed prospective primary research studies, which conform to the paradigm of diagnostic test accuracy assessment, are required to investigate the accuracy of FAF imaging in diagnosis and monitoring of inherited retinal dystrophies, early age-related macular degeneration, geographic atrophy and central serous chorioretinopathy. This study is registered as PROSPERO CRD42014014997. The National Institute for Health Research Health Technology Assessment programme.

  8. The Effect of Moderate and High-Intensity Fatigue on Groundstroke Accuracy in Expert and Non-Expert Tennis Players

    PubMed Central

    Lyons, Mark; Al-Nakeeb, Yahya; Hankey, Joanne; Nevill, Alan

    2013-01-01

    Exploring the effects of fatigue on skilled performance in tennis presents a significant challenge to the researcher with respect to ecological validity. This study examined the effects of moderate and high-intensity fatigue on groundstroke accuracy in expert and non-expert tennis players. The research also explored whether the effects of fatigue are the same regardless of gender and player’s achievement motivation characteristics. 13 expert (7 male, 6 female) and 17 non-expert (13 male, 4 female) tennis players participated in the study. Groundstroke accuracy was assessed using the modified Loughborough Tennis Skills Test. Fatigue was induced using the Loughborough Intermittent Tennis Test with moderate (70%) and high-intensities (90%) set as a percentage of peak heart rate (attained during a tennis-specific maximal hitting sprint test). Ratings of perceived exertion were used as an adjunct to the monitoring of heart rate. Achievement goal indicators for each player were assessed using the 2 x 2 Achievement Goals Questionnaire for Sport in an effort to examine if this personality characteristic provides insight into how players perform under moderate and high-intensity fatigue conditions. A series of mixed ANOVA’s revealed significant fatigue effects on groundstroke accuracy regardless of expertise. The expert players however, maintained better groundstroke accuracy across all conditions compared to the novice players. Nevertheless, in both groups, performance following high-intensity fatigue deteriorated compared to performance at rest and performance while moderately fatigued. Groundstroke accuracy under moderate levels of fatigue was equivalent to that at rest. Fatigue effects were also similar regardless of gender. No fatigue by expertise, or fatigue by gender interactions were found. Fatigue effects were also equivalent regardless of player’s achievement goal indicators. Future research is required to explore the effects of fatigue on performance in tennis using ecologically valid designs that mimic more closely the demands of match play. Key Points Groundstroke accuracy under moderate-intensity fatigue is equivalent to performance at rest. Groundstroke accuracy declines significantly in both expert (40.3% decline) and non-expert (49.6%) tennis players following high-intensity fatigue. Expert players are more consistent, hit more accurate shots and fewer out shots across all fatigue intensities. The effects of fatigue on groundstroke accuracy are the same regardless of gender and player’s achievement goal indicators. PMID:24149809

  9. A comparison of five methods to predict genomic breeding values of dairy bulls from genome-wide SNP markers

    PubMed Central

    2009-01-01

    Background Genomic selection (GS) uses molecular breeding values (MBV) derived from dense markers across the entire genome for selection of young animals. The accuracy of MBV prediction is important for a successful application of GS. Recently, several methods have been proposed to estimate MBV. Initial simulation studies have shown that these methods can accurately predict MBV. In this study we compared the accuracies and possible bias of five different regression methods in an empirical application in dairy cattle. Methods Genotypes of 7,372 SNP and highly accurate EBV of 1,945 dairy bulls were used to predict MBV for protein percentage (PPT) and a profit index (Australian Selection Index, ASI). Marker effects were estimated by least squares regression (FR-LS), Bayesian regression (Bayes-R), random regression best linear unbiased prediction (RR-BLUP), partial least squares regression (PLSR) and nonparametric support vector regression (SVR) in a training set of 1,239 bulls. Accuracy and bias of MBV prediction were calculated from cross-validation of the training set and tested against a test team of 706 young bulls. Results For both traits, FR-LS using a subset of SNP was significantly less accurate than all other methods which used all SNP. Accuracies obtained by Bayes-R, RR-BLUP, PLSR and SVR were very similar for ASI (0.39-0.45) and for PPT (0.55-0.61). Overall, SVR gave the highest accuracy. All methods resulted in biased MBV predictions for ASI, for PPT only RR-BLUP and SVR predictions were unbiased. A significant decrease in accuracy of prediction of ASI was seen in young test cohorts of bulls compared to the accuracy derived from cross-validation of the training set. This reduction was not apparent for PPT. Combining MBV predictions with pedigree based predictions gave 1.05 - 1.34 times higher accuracies compared to predictions based on pedigree alone. Some methods have largely different computational requirements, with PLSR and RR-BLUP requiring the least computing time. Conclusions The four methods which use information from all SNP namely RR-BLUP, Bayes-R, PLSR and SVR generate similar accuracies of MBV prediction for genomic selection, and their use in the selection of immediate future generations in dairy cattle will be comparable. The use of FR-LS in genomic selection is not recommended. PMID:20043835

  10. Amylase in drain fluid for the diagnosis of pancreatic leak in post-pancreatic resection.

    PubMed

    Davidson, Tsetsegdemberel Bat-Ulzii; Yaghoobi, Mohammad; Davidson, Brian R; Gurusamy, Kurinchi Selvan

    2017-04-07

    The treatment of people with clinically significant postoperative pancreatic leaks is different from those without clinically significant pancreatic leaks. It is important to know the diagnostic accuracy of drain fluid amylase as a triage test for the detection of clinically significant pancreatic leaks, so that an informed decision can be made as to whether the patient with a suspected pancreatic leak needs further investigations and treatment. There is currently no systematic review of the diagnostic test accuracy of drain fluid amylase for the diagnosis of clinically relevant pancreatic leak. To determine the diagnostic accuracy of amylase in drain fluid at 48 hours or more for the diagnosis of pancreatic leak in people who had undergone pancreatic resection. We searched MEDLINE, Embase, the Science Citation Index Expanded, and the National Institute for Health Research Health Technology Assessment (NIHR HTA) websites up to 20 February 2017. We searched the references of the included studies to identify additional studies. We did not restrict studies based on language or publication status, or whether data were collected prospectively or retrospectively. We also performed a 'related search' and 'citing reference' search in MEDLINE and Embase. We included all studies that evaluated the diagnostic test accuracy of amylase in the drain fluid at 48 hours or more for the diagnosis of pancreatic leak in people who had undergone pancreatic resection excluding total pancreatectomy. We planned to exclude case-control studies because these studies are prone to bias, but did not find any. At least two authors independently searched and screened the references produced by the search to identify relevant studies. Two review authors independently extracted data from the included studies. The included studies reported drain fluid amylase on different postoperative days and measured at different cut-off levels, so it was not possible to perform a meta-analysis using the bivariate model as planned. We have reported the sensitivity, specificity, post-test probability of a positive and negative drain fluid amylase along with 95% confidence interval (CI) on each of the different postoperative days and measured at different cut-off levels. A total of five studies including 868 participants met the inclusion criteria for this review. The five studies included in this review reported the value of drain fluid amylase at different thresholds and different postoperative days. The sensitivities and specificities were variable; the sensitivities ranged between 0.72 and 1.00 while the specificities ranged between 0.73 and 0.99 for different thresholds on different postoperative days. At the median prevalence (pre-test probability) of 15.9%, the post-test probabilities for pancreatic leak ranged between 35.9% and 95.4% for a positive drain fluid amylase test and ranged between 0% and 5.5% for a negative drain fluid amylase test.None of the studies used the reference standard of confirmation by surgery or by a combination of surgery and clinical follow-up, but used the International Study Group on Pancreatic Fistula (ISGPF) grade B and C as the reference standard. The overall methodological quality was unclear or high in all the studies. Because of the paucity of data and methodological deficiencies in the studies, we are uncertain whether drain fluid amylase should be used as a method for testing for pancreatic leak in an unselected population after pancreatic resection; and we judge that the optimal cut-off of drain fluid amylase for making the diagnosis of pancreatic leak is also not clear. Further well-designed diagnostic test accuracy studies with pre-specified index test threshold of drain fluid amylase (at three times more on postoperative day 5 or another suitable pre-specified threshold), appropriate follow-up (for at least six to eight weeks to ensure that there are no pancreatic leaks), and clearly defined reference standards (of surgical, clinical, and radiological confirmation of pancreatic leak) are important to reliably determine the diagnostic accuracy of drain fluid amylase in the diagnosis of pancreatic leak.

  11. APPLICATION OF NONINVASIVE PREGNANCY DIAGNOSIS IN BACTRIAN CAMELS (CAMELUS BACTRIANUS) USING CUBONI REACTION AND BARIUM CHLORIDE TEST.

    PubMed

    Fedorova, Tamara; Brandlová, Karolína; Lukešová, Daniela

    2015-06-01

    Pregnancy diagnoses in half-tamed animals are often very complicated. This study aimed to examine the alternative noninvasive and cheap methods of pregnancy diagnosis from urine in domestic Bactrian camels (Camelus bactrianus). Urine from 14 female camels kept in four European zoologic gardens was collected and tested by two chemical tests--Cuboni reaction and barium chloride test. The Cuboni reaction was significantly (P<0.01) affected by the pregnancy status of female camels. The total accuracy of the Cuboni reaction was 70.5% but it increased significantly (P<0.05) in the time leading up to parturition. The accuracy was 100% in the 3rd third of pregnancy. Urine of nonpregnant females did not react with a solution of barium chloride while, contrary to other studies, white precipitates formed mostly (80 to 100%) in urine of pregnant females. This study concluded that the Cuboni reaction is applicable for pregnancy diagnosis in camels.

  12. The Effect of Involuntary Motor Activity on Myoelectric Pattern Recognition: A Case Study with Chronic Stroke Patients

    PubMed Central

    Zhang, Xu; Li, Yun; Chen, Xiang; Li, Guanglin; Rymer, William Zev; Zhou, Ping

    2013-01-01

    This study investigates the effect of involuntary motor activity of paretic-spastic muscles on classification of surface electromyography (EMG) signals. Two data collection sessions were designed for 8 stroke subjects to voluntarily perform 11 functional movements using their affected forearm and hand at a relatively slow and fast speed. For each stroke subject, the degree of involuntary motor activity present in voluntary surface EMG recordings was qualitatively described from such slow and fast experimental protocols. Myoelectric pattern recognition analysis was performed using different combinations of voluntary surface EMG data recorded from slow and fast sessions. Across all tested stroke subjects, our results revealed that when involuntary surface EMG was absent or present in both training and testing datasets, high accuracies (> 96%, > 98%, respectively, averaged over all the subjects) can be achieved in classification of different movements using surface EMG signals from paretic muscles. When involuntary surface EMG was solely involved in either training or testing datasets, the classification accuracies were dramatically reduced (< 89%, < 85%, respectively). However, if both training and testing datasets contained EMG signals with presence and absence of involuntary EMG interference, high accuracies were still achieved (> 97%). The findings of this study can be used to guide appropriate design and implementation of myoelectric pattern recognition based systems or devices toward promoting robot-aided therapy for stroke rehabilitation. PMID:23860192

  13. Estimation of diagnostic test accuracy without full verification: a review of latent class methods

    PubMed Central

    Collins, John; Huynh, Minh

    2014-01-01

    The performance of a diagnostic test is best evaluated against a reference test that is without error. For many diseases, this is not possible, and an imperfect reference test must be used. However, diagnostic accuracy estimates may be biased if inaccurately verified status is used as the truth. Statistical models have been developed to handle this situation by treating disease as a latent variable. In this paper, we conduct a systematized review of statistical methods using latent class models for estimating test accuracy and disease prevalence in the absence of complete verification. PMID:24910172

  14. The Potential Impact of Not Being Able to Create Parallel Tests on Expected Classification Accuracy

    ERIC Educational Resources Information Center

    Wyse, Adam E.

    2011-01-01

    In many practical testing situations, alternate test forms from the same testing program are not strictly parallel to each other and instead the test forms exhibit small psychometric differences. This article investigates the potential practical impact that these small psychometric differences can have on expected classification accuracy. Ten…

  15. Continuous Glucose Monitoring and Trend Accuracy

    PubMed Central

    Gottlieb, Rebecca; Le Compte, Aaron; Chase, J. Geoffrey

    2014-01-01

    Continuous glucose monitoring (CGM) devices are being increasingly used to monitor glycemia in people with diabetes. One advantage with CGM is the ability to monitor the trend of sensor glucose (SG) over time. However, there are few metrics available for assessing the trend accuracy of CGM devices. The aim of this study was to develop an easy to interpret tool for assessing trend accuracy of CGM data. SG data from CGM were compared to hourly blood glucose (BG) measurements and trend accuracy was quantified using the dot product. Trend accuracy results are displayed on the Trend Compass, which depicts trend accuracy as a function of BG. A trend performance table and Trend Index (TI) metric are also proposed. The Trend Compass was tested using simulated CGM data with varying levels of error and variability, as well as real clinical CGM data. The results show that the Trend Compass is an effective tool for differentiating good trend accuracy from poor trend accuracy, independent of glycemic variability. Furthermore, the real clinical data show that the Trend Compass assesses trend accuracy independent of point bias error. Finally, the importance of assessing trend accuracy as a function of BG level is highlighted in a case example of low and falling BG data, with corresponding rising SG data. This study developed a simple to use tool for quantifying trend accuracy. The resulting trend accuracy is easily interpreted on the Trend Compass plot, and if required, performance table and TI metric. PMID:24876437

  16. SVM-RFE based feature selection and Taguchi parameters optimization for multiclass SVM classifier.

    PubMed

    Huang, Mei-Ling; Hung, Yung-Hsiang; Lee, W M; Li, R K; Jiang, Bo-Ru

    2014-01-01

    Recently, support vector machine (SVM) has excellent performance on classification and prediction and is widely used on disease diagnosis or medical assistance. However, SVM only functions well on two-group classification problems. This study combines feature selection and SVM recursive feature elimination (SVM-RFE) to investigate the classification accuracy of multiclass problems for Dermatology and Zoo databases. Dermatology dataset contains 33 feature variables, 1 class variable, and 366 testing instances; and the Zoo dataset contains 16 feature variables, 1 class variable, and 101 testing instances. The feature variables in the two datasets were sorted in descending order by explanatory power, and different feature sets were selected by SVM-RFE to explore classification accuracy. Meanwhile, Taguchi method was jointly combined with SVM classifier in order to optimize parameters C and γ to increase classification accuracy for multiclass classification. The experimental results show that the classification accuracy can be more than 95% after SVM-RFE feature selection and Taguchi parameter optimization for Dermatology and Zoo databases.

  17. SVM-RFE Based Feature Selection and Taguchi Parameters Optimization for Multiclass SVM Classifier

    PubMed Central

    Huang, Mei-Ling; Hung, Yung-Hsiang; Lee, W. M.; Li, R. K.; Jiang, Bo-Ru

    2014-01-01

    Recently, support vector machine (SVM) has excellent performance on classification and prediction and is widely used on disease diagnosis or medical assistance. However, SVM only functions well on two-group classification problems. This study combines feature selection and SVM recursive feature elimination (SVM-RFE) to investigate the classification accuracy of multiclass problems for Dermatology and Zoo databases. Dermatology dataset contains 33 feature variables, 1 class variable, and 366 testing instances; and the Zoo dataset contains 16 feature variables, 1 class variable, and 101 testing instances. The feature variables in the two datasets were sorted in descending order by explanatory power, and different feature sets were selected by SVM-RFE to explore classification accuracy. Meanwhile, Taguchi method was jointly combined with SVM classifier in order to optimize parameters C and γ to increase classification accuracy for multiclass classification. The experimental results show that the classification accuracy can be more than 95% after SVM-RFE feature selection and Taguchi parameter optimization for Dermatology and Zoo databases. PMID:25295306

  18. Triple Test in Carcinoma Breast

    PubMed Central

    Sameer; Mukherjee, Arindam

    2014-01-01

    Introduction: The commonest clinical presentation in majority of breast pathology is a lump. A definite diagnosis of breast lump is very important for the surgeon to decide on the final course of treatment and also saves the patient from unnecessary physical, emotional and psychological trauma if there is a definite preoperative diagnosis of benign lesion. The present study was done to evaluate the effectiveness and relevance of “TRIPLE TEST”in diagnosis of carcinoma breast in rural labour class population. Materials and Methods: The present study was a prospective study conducted on patients over 35 years of age having palpable breast lumps presenting in the out patient department of general surgery, ESI Hospital Basaidarapur New Delhi, India. The duration of study was from May 2007 to June 2009 and a total of 100 cases were studied. Each patient was subjected to a detailed history, clinical breast examination ,diagnostic mammography and FNAC. In this study, the results of each modality was divided in three groups: benign, suspicious and malignant. The sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of each test was calculated individually and as combined. Result: Out of 100 patients enrolled in this study, 60 cases were benign and 40 cases were of malignant breast disease. The age of patients with carcinoma breast in the series varied from 35 years to 70 years. The highest incidence of malignancy noted was 30% in 41-50 years age group (4th decade) followed by 27.5% in 51-60 years age group (5th decade). The sensitivity of clinical examination was found to be 75%, specificity was 83.3%, positive predictive value (PPV) of 75% and diagnostic accuracy of 80%. The sensitivity, specificity, positive predictive value and diagnostic accuracy of mammography was calculated and was found to be 94.9% , 90% , 86% and 92% respectively. The sensitivity, specificity, positive predictive value and diagnostic accuracy of FNAC was 94.7%, 98.3%, 97.3% and 96.6% respectively. Out of 100 cases triple test was concordant (all three test either benign or malignant) in 80 cases, all the benign cases detected by triple test were benign on final biopsy i.e. 100% specificity and 100% negative predictive value. Conclusion: TTS is an accurate and least invasive diagnostic test based on which definitive treatment can be initiated. PMID:25478391

  19. Face Validity of Test and Acceptance of Generalized Personality Interpretations

    ERIC Educational Resources Information Center

    Delprato, Dennis J.

    1975-01-01

    The degree to which variations in the face validity of psychological tests affected students' willingness to accept personality interpretations was studied. Acceptance of personality interpretations was compared for four types of tests which varied in face validity. The relationship between judged accuracy and rated likability of the…

  20. Confidence Wagering during Mathematics and Science Testing

    ERIC Educational Resources Information Center

    Jack, Brady Michael; Liu, Chia-Ju; Chiu, Hoan-Lin; Shymansky, James A.

    2009-01-01

    This proposal presents the results of a case study involving five 8th grade Taiwanese classes, two mathematics and three science classes. These classes used a new method of testing called confidence wagering. This paper advocates the position that confidence wagering can predict the accuracy of a student's test answer selection during…

  1. Zagreb Amblyopia Preschool Screening Study: near and distance visual acuity testing increase the diagnostic accuracy of screening for amblyopia.

    PubMed

    Bušić, Mladen; Bjeloš, Mirjana; Petrovečki, Mladen; Kuzmanović Elabjer, Biljana; Bosnar, Damir; Ramić, Senad; Miletić, Daliborka; Andrijašević, Lidija; Kondža Krstonijević, Edita; Jakovljević, Vid; Bišćan Tvrdi, Ana; Predović, Jurica; Kokot, Antonio; Bišćan, Filip; Kovačević Ljubić, Mirna; Motušić Aras, Ranka

    2016-02-01

    To present and evaluate a new screening protocol for amblyopia in preschool children. Zagreb Amblyopia Preschool Screening (ZAPS) study protocol performed screening for amblyopia by near and distance visual acuity (VA) testing of 15 648 children aged 48-54 months attending kindergartens in the City of Zagreb County between September 2011 and June 2014 using Lea Symbols in lines test. If VA in either eye was >0.1 logMAR, the child was re-tested, if failed at re-test, the child was referred to comprehensive eye examination at the Eye Clinic. 78.04% of children passed the screening test. Estimated prevalence of amblyopia was 8.08%. Testability, sensitivity, and specificity of the ZAPS study protocol were 99.19%, 100.00%, and 96.68% respectively. The ZAPS study used the most discriminative VA test with optotypes in line as they do not underestimate amblyopia. The estimated prevalence of amblyopia was considerably higher than reported elsewhere. To the best of our knowledge, the ZAPS study protocol reached the highest sensitivity and specificity when evaluating diagnostic accuracy of VA tests for screening. The pass level defined at ≤0.1 logMAR for 4-year-old children, using Lea Symbols in lines missed no amblyopia cases, advocating that both near and distance VA testing should be performed when screening for amblyopia.

  2. Zagreb Amblyopia Preschool Screening Study: near and distance visual acuity testing increase the diagnostic accuracy of screening for amblyopia

    PubMed Central

    Bušić, Mladen; Bjeloš, Mirjana; Petrovečki, Mladen; Kuzmanović Elabjer, Biljana; Bosnar, Damir; Ramić, Senad; Miletić, Daliborka; Andrijašević, Lidija; Kondža Krstonijević, Edita; Jakovljević, Vid; Bišćan Tvrdi, Ana; Predović, Jurica; Kokot, Antonio; Bišćan, Filip; Kovačević Ljubić, Mirna; Motušić Aras, Ranka

    2016-01-01

    Aim To present and evaluate a new screening protocol for amblyopia in preschool children. Methods Zagreb Amblyopia Preschool Screening (ZAPS) study protocol performed screening for amblyopia by near and distance visual acuity (VA) testing of 15 648 children aged 48-54 months attending kindergartens in the City of Zagreb County between September 2011 and June 2014 using Lea Symbols in lines test. If VA in either eye was >0.1 logMAR, the child was re-tested, if failed at re-test, the child was referred to comprehensive eye examination at the Eye Clinic. Results 78.04% of children passed the screening test. Estimated prevalence of amblyopia was 8.08%. Testability, sensitivity, and specificity of the ZAPS study protocol were 99.19%, 100.00%, and 96.68% respectively. Conclusion The ZAPS study used the most discriminative VA test with optotypes in lines as they do not underestimate amblyopia. The estimated prevalence of amblyopia was considerably higher than reported elsewhere. To the best of our knowledge, the ZAPS study protocol reached the highest sensitivity and specificity when evaluating diagnostic accuracy of VA tests for screening. The pass level defined at ≤0.1 logMAR for 4-year-old children, using Lea Symbols in lines missed no amblyopia cases, advocating that both near and distance VA testing should be performed when screening for amblyopia. PMID:26935612

  3. Body Mass Index is a Poor Predictor of Bedside Appendix Ultrasound Success or Accuracy

    PubMed Central

    Lam, Samuel H.F.; Kerwin, Christopher; Konicki, P. John; Goodwine, Diana; Lambert, Michael J.

    2016-01-01

    Introduction The objective of this study was to determine whether there is a relationship between body mass index (BMI) and success or accuracy rate of beside ultrasound (BUS) for the diagnosis of appendicitis. Methods Patients four years of age and older presenting to the emergency department with suspected appendicitis were eligible. Enrollment was by convenience sampling. After informed consent, BUS was performed by trained emergency physicians who had undergone a minimum of one-hour didactic training on the use of BUS to diagnose appendicitis. We ascertained subject outcomes by a combination of medical record review and telephone follow up. Calculated BMI for adults and children were divided into four categories (underweight, normal, overweight, obese) according to Centers for Disease Control and Prevention classifications. Results A total of 125 subjects consented for the study, and 116 of them had adequate image data for final analysis. Seventy (60%) of the subjects were children. Prevalence of appendicitis was 39%. Fifty-two (45%) of the BUS studies were diagnostic (successful). Overall accuracy rate was 75%. Analysis by chi-square test or Mann-Whitney U test did not find any significant correlation between BMI category and BUS success. Similarly, there was no significant correlation between BMI category and BUS accuracy. The same conclusion was reached when children and adults were analyzed separately, or when subjects were dichotomized into underweight/normal and overweight/obese categories. Conclusion BMI category alone is a poor predictor of appendix BUS success or accuracy. PMID:27429696

  4. Glenohumeral articular cartilage lesions: prospective comparison of non-contrast magnetic resonance imaging and findings at arthroscopy.

    PubMed

    Spencer, Brian A; Dolinskas, Carol A; Seymour, Peter A; Thomas, Stephen J; Abboud, Joseph A

    2013-09-01

    The purpose of this study was to assess the diagnostic sensitivity, specificity, accuracy, negative predictive value (NPV), positive predictive value (PPV), and test-retest reliability of magnetic resonance imaging (MRI) for detecting cartilage abnormalities of the glenohumeral joint in comparison with the gold standard of diagnostic arthroscopy. Forty-four patients with a preoperative non-contrast MRI study of their affected shoulder underwent arthroscopy by one surgeon for rotator cuff tendinopathy from 2009 to 2010. Articular cartilage defects were prospectively recorded and graded according to the International Cartilage Repair Society classification system at the time of arthroscopy. One year after surgery, the preoperative MRI were reviewed by a board-certified radiologist and the treating surgeon for articular cartilage defects of both the humeral head and the glenoid. Sensitivity, specificity, accuracy, and test-retest reliability were calculated. At arthroscopy, 43% of the shoulders were found to have articular cartilage defects. When the readers' findings were combined, the sensitivity of detecting humeral lesions on MRI was 32%; specificity, 80%; accuracy, 63%; PPV, 57%; and NPV, 66%. The sensitivity of detecting glenoid lesions was 31%; specificity, 86%; accuracy, 76%; PPV, 33%; and NPV, 85%. This study finds that the overall accuracy of MRI in detecting articular cartilage damage in patients with the clinical diagnosis of subacromial pathology is moderate. Level II, development of diagnostic criteria based on consecutive patients with universally applied reference "gold" standard. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  5. Comparative analysis of Worldview-2 and Landsat 8 for coastal saltmarsh mapping accuracy assessment

    NASA Astrophysics Data System (ADS)

    Rasel, Sikdar M. M.; Chang, Hsing-Chung; Diti, Israt Jahan; Ralph, Tim; Saintilan, Neil

    2016-05-01

    Coastal saltmarsh and their constituent components and processes are of an interest scientifically due to their ecological function and services. However, heterogeneity and seasonal dynamic of the coastal wetland system makes it challenging to map saltmarshes with remotely sensed data. This study selected four important saltmarsh species Pragmitis australis, Sporobolus virginicus, Ficiona nodosa and Schoeloplectus sp. as well as a Mangrove and Pine tree species, Avecinia and Casuarina sp respectively. High Spatial Resolution Worldview-2 data and Coarse Spatial resolution Landsat 8 imagery were selected in this study. Among the selected vegetation types some patches ware fragmented and close to the spatial resolution of Worldview-2 data while and some patch were larger than the 30 meter resolution of Landsat 8 data. This study aims to test the effectiveness of different classifier for the imagery with various spatial and spectral resolutions. Three different classification algorithm, Maximum Likelihood Classifier (MLC), Support Vector Machine (SVM) and Artificial Neural Network (ANN) were tested and compared with their mapping accuracy of the results derived from both satellite imagery. For Worldview-2 data SVM was giving the higher overall accuracy (92.12%, kappa =0.90) followed by ANN (90.82%, Kappa 0.89) and MLC (90.55%, kappa = 0.88). For Landsat 8 data, MLC (82.04%) showed the highest classification accuracy comparing to SVM (77.31%) and ANN (75.23%). The producer accuracy of the classification results were also presented in the paper.

  6. Relationship between accuracy and complexity when learning underarm precision throwing.

    PubMed

    Valle, Maria Stella; Lombardo, Luciano; Cioni, Matteo; Casabona, Antonino

    2018-06-12

    Learning precision ball throwing was mostly studied to explore the early rapid improvement of accuracy, with poor attention on possible adaptive processes occurring later when the rate of improvement is reduced. Here, we tried to demonstrate that the strategy to select angle, speed and height at ball release can be managed during the learning periods following the performance stabilization. To this aim, we used a multivariate linear model with angle, speed and height as predictors of changes in accuracy. Participants performed underarm throws of a tennis ball to hit a target on the floor, 3.42 m away. Two training sessions (S1, S2) and one retention test were executed. Performance accuracy increased over the S1 and stabilized during the S2, with a rate of changes along the throwing axis slower than along the orthogonal axis. However, both the axes contributed to the performance changes over the learning and consolidation time. A stable relationship between the accuracy and the release parameters was observed only during S2, with a good fraction of the performance variance explained by the combination of speed and height. All the variations were maintained during the retention test. Overall, accuracy improvements and reduction in throwing complexity at the ball release followed separate timing over the course of learning and consolidation.

  7. Classification of right-hand grasp movement based on EMOTIV Epoc+

    NASA Astrophysics Data System (ADS)

    Tobing, T. A. M. L.; Prawito, Wijaya, S. K.

    2017-07-01

    Combinations of BCT elements for right-hand grasp movement have been obtained, providing the average value of their classification accuracy. The aim of this study is to find a suitable combination for best classification accuracy of right-hand grasp movement based on EEG headset, EMOTIV Epoc+. There are three movement classifications: grasping hand, relax, and opening hand. These classifications take advantage of Event-Related Desynchronization (ERD) phenomenon that makes it possible to differ relaxation, imagery, and movement state from each other. The combinations of elements are the usage of Independent Component Analysis (ICA), spectrum analysis by Fast Fourier Transform (FFT), maximum mu and beta power with their frequency as features, and also classifier Probabilistic Neural Network (PNN) and Radial Basis Function (RBF). The average values of classification accuracy are ± 83% for training and ± 57% for testing. To have a better understanding of the signal quality recorded by EMOTIV Epoc+, the result of classification accuracy of left or right-hand grasping movement EEG signal (provided by Physionet) also be given, i.e.± 85% for training and ± 70% for testing. The comparison of accuracy value from each combination, experiment condition, and external EEG data are provided for the purpose of value analysis of classification accuracy.

  8. 40 CFR 63.3968 - What are the requirements for continuous parameter monitoring system installation, operation, and...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... temperature simulation devices. (v) Conduct a visual inspection of each sensor every quarter if redundant... signal simulations or via relative accuracy testing. (v) Conduct an accuracy audit every quarter and... signal simulations or via relative accuracy testing. (vi) Perform leak checks monthly. (vii) Perform...

  9. 40 CFR 63.3968 - What are the requirements for continuous parameter monitoring system installation, operation, and...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... temperature simulation devices. (v) Conduct a visual inspection of each sensor every quarter if redundant... signal simulations or via relative accuracy testing. (v) Conduct an accuracy audit every quarter and... signal simulations or via relative accuracy testing. (vi) Perform leak checks monthly. (vii) Perform...

  10. 40 CFR 63.3968 - What are the requirements for continuous parameter monitoring system installation, operation, and...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... temperature simulation devices. (v) Conduct a visual inspection of each sensor every quarter if redundant... signal simulations or via relative accuracy testing. (v) Conduct an accuracy audit every quarter and... signal simulations or via relative accuracy testing. (vi) Perform leak checks monthly. (vii) Perform...

  11. Monitoring memory errors: the influence of the veracity of retrieved information on the accuracy of judgements of learning.

    PubMed

    Rhodes, Matthew G; Tauber, Sarah K

    2011-11-01

    The current study examined the degree to which predictions of memory performance made immediately or at a delay are sensitive to confidently held memory illusions. Participants studied unrelated pairs of words and made judgements of learning (JOLs) for each item, either immediately or after a delay. Half of the unrelated pairs (deceptive items; e.g., nurse-dollar) had a semantically related competitor (e.g., doctor) that was easily accessible when given a test cue (e.g., nurse-do_ _ _r) and half had no semantically related competitor (control items; e.g., subject-dollar). Following the study phase, participants were administered a cued recall test. Results from Experiment 1 showed that memory performance was less accurate for deceptive compared with control items. In addition, delaying judgement improved the relative accuracy of JOLs for control items but not for deceptive items. Subsequent experiments explored the degree to which the relative accuracy of delayed JOLs for deceptive items improved as a result of a warning to ensure that retrieved memories were accurate (Experiment 2) and corrective feedback regarding the veracity of information retrieved prior to making a JOL (Experiment 3). In all, these data suggest that delayed JOLs may be largely insensitive to memory errors unless participants are provided with feedback regarding memory accuracy.

  12. Accuracy of a smartphone to test laryngoscope's light and an audit to our laryngoscopes using an ISO standard.

    PubMed

    Machado, Diogo Alcino de Abreu Ribeiro Carvalho; Esteves, Dina da Assunção Azevedo; Branca, Pedro Manuel Araújo de Sousa

    Laryngoscope is a key tool in anesthetic practice. Direct laryngoscopy is a crucial moment and inadequate laryngoscope's light can lead to catastrophic consequences. From our experience laryngoscope's light is assessed in a subjective manner and we believe a more precise evaluation should be used. Our objective is to compare the accuracy of a smartphone compared to a lux meter. Secondly we audited our Operating Room laryngoscopes. We designed a pragmatic study, using as primary outcome the accuracy of a smartphone compared to the lux meter. Further we audited with both the lux meter and the smartphone all laryngoscopes and blades ready to use in our Operating Rooms, using the International Standard form the International Organization for Standardization. For primary outcome we found no significant difference between devices. Our audit showed that only 2 in 48 laryngoscopes complied with the ISO norm. When comparing the measurements between the lux meter and the smartphone we found no significant difference. Ideally every laryngoscope should perform as required. We believe all laryngoscopes should have a practical but reliable and objective test prior to its utilization. Our results suggest the smartphone was accurate enough to be used as a lux meter to test laryngoscope's light. Audit results showing only 4% comply with the ISO standard are consistent with other studies. The tested smartphone has enough accuracy to perform light measurement in laryngoscopes. We believe this is a step further to perform an objective routine check to laryngoscope's light. Copyright © 2016. Published by Elsevier Editora Ltda.

  13. High accuracy differential pressure measurements using fluid-filled catheters - A feasibility study in compliant tubes.

    PubMed

    Rotman, Oren Moshe; Weiss, Dar; Zaretsky, Uri; Shitzer, Avraham; Einav, Shmuel

    2015-09-18

    High accuracy differential pressure measurements are required in various biomedical and medical applications, such as in fluid-dynamic test systems, or in the cath-lab. Differential pressure measurements using fluid-filled catheters are relatively inexpensive, yet may be subjected to common mode pressure errors (CMP), which can significantly reduce the measurement accuracy. Recently, a novel correction method for high accuracy differential pressure measurements was presented, and was shown to effectively remove CMP distortions from measurements acquired in rigid tubes. The purpose of the present study was to test the feasibility of this correction method inside compliant tubes, which effectively simulate arteries. Two tubes with varying compliance were tested under dynamic flow and pressure conditions to cover the physiological range of radial distensibility in coronary arteries. A third, compliant model, with a 70% stenosis severity was additionally tested. Differential pressure measurements were acquired over a 3 cm tube length using a fluid-filled double-lumen catheter, and were corrected using the proposed CMP correction method. Validation of the corrected differential pressure signals was performed by comparison to differential pressure recordings taken via a direct connection to the compliant tubes, and by comparison to predicted differential pressure readings of matching fluid-structure interaction (FSI) computational simulations. The results show excellent agreement between the experimentally acquired and computationally determined differential pressure signals. This validates the application of the CMP correction method in compliant tubes of the physiological range for up to intermediate size stenosis severity of 70%. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Summarising and validating test accuracy results across multiple studies for use in clinical practice.

    PubMed

    Riley, Richard D; Ahmed, Ikhlaaq; Debray, Thomas P A; Willis, Brian H; Noordzij, J Pieter; Higgins, Julian P T; Deeks, Jonathan J

    2015-06-15

    Following a meta-analysis of test accuracy studies, the translation of summary results into clinical practice is potentially problematic. The sensitivity, specificity and positive (PPV) and negative (NPV) predictive values of a test may differ substantially from the average meta-analysis findings, because of heterogeneity. Clinicians thus need more guidance: given the meta-analysis, is a test likely to be useful in new populations, and if so, how should test results inform the probability of existing disease (for a diagnostic test) or future adverse outcome (for a prognostic test)? We propose ways to address this. Firstly, following a meta-analysis, we suggest deriving prediction intervals and probability statements about the potential accuracy of a test in a new population. Secondly, we suggest strategies on how clinicians should derive post-test probabilities (PPV and NPV) in a new population based on existing meta-analysis results and propose a cross-validation approach for examining and comparing their calibration performance. Application is made to two clinical examples. In the first example, the joint probability that both sensitivity and specificity will be >80% in a new population is just 0.19, because of a low sensitivity. However, the summary PPV of 0.97 is high and calibrates well in new populations, with a probability of 0.78 that the true PPV will be at least 0.95. In the second example, post-test probabilities calibrate better when tailored to the prevalence in the new population, with cross-validation revealing a probability of 0.97 that the observed NPV will be within 10% of the predicted NPV. © 2015 The Authors. Statistics in Medicine Published by John Wiley & Sons Ltd.

  15. Sensitivity and specificity of normality tests and consequences on reference interval accuracy at small sample size: a computer-simulation study.

    PubMed

    Le Boedec, Kevin

    2016-12-01

    According to international guidelines, parametric methods must be chosen for RI construction when the sample size is small and the distribution is Gaussian. However, normality tests may not be accurate at small sample size. The purpose of the study was to evaluate normality test performance to properly identify samples extracted from a Gaussian population at small sample sizes, and assess the consequences on RI accuracy of applying parametric methods to samples that falsely identified the parent population as Gaussian. Samples of n = 60 and n = 30 values were randomly selected 100 times from simulated Gaussian, lognormal, and asymmetric populations of 10,000 values. The sensitivity and specificity of 4 normality tests were compared. Reference intervals were calculated using 6 different statistical methods from samples that falsely identified the parent population as Gaussian, and their accuracy was compared. Shapiro-Wilk and D'Agostino-Pearson tests were the best performing normality tests. However, their specificity was poor at sample size n = 30 (specificity for P < .05: .51 and .50, respectively). The best significance levels identified when n = 30 were 0.19 for Shapiro-Wilk test and 0.18 for D'Agostino-Pearson test. Using parametric methods on samples extracted from a lognormal population but falsely identified as Gaussian led to clinically relevant inaccuracies. At small sample size, normality tests may lead to erroneous use of parametric methods to build RI. Using nonparametric methods (or alternatively Box-Cox transformation) on all samples regardless of their distribution or adjusting, the significance level of normality tests depending on sample size would limit the risk of constructing inaccurate RI. © 2016 American Society for Veterinary Clinical Pathology.

  16. METACOGNITIVE SCAFFOLDS IMPROVE SELF-JUDGMENTS OF ACCURACY IN A MEDICAL INTELLIGENT TUTORING SYSTEM

    PubMed Central

    Feyzi-Behnagh, Reza; Azevedo, Roger; Legowski, Elizabeth; Reitmeyer, Kayse; Tseytlin, Eugene; Crowley, Rebecca S.

    2013-01-01

    In this study, we examined the effect of two metacognitive scaffolds on the accuracy of confidence judgments made while diagnosing dermatopathology slides in SlideTutor. Thirty-one (N = 31) first- to fourth-year pathology and dermatology residents were randomly assigned to one of the two scaffolding conditions. The cases used in this study were selected from the domain of Nodular and Diffuse Dermatitides. Both groups worked with a version of SlideTutor that provided immediate feedback on their actions for two hours before proceeding to solve cases in either the Considering Alternatives or Playback condition. No immediate feedback was provided on actions performed by participants in the scaffolding mode. Measurements included learning gains (pre-test and post-test), as well as metacognitive performance, including Goodman-Kruskal Gamma correlation, bias, and discrimination. Results showed that participants in both conditions improved significantly in terms of their diagnostic scores from pre-test to post-test. More importantly, participants in the Considering Alternatives condition outperformed those in the Playback condition in the accuracy of their confidence judgments and the discrimination of the correctness of their assertions while solving cases. The results suggested that presenting participants with their diagnostic decision paths and highlighting correct and incorrect paths helps them to become more metacognitively accurate in their confidence judgments. PMID:24532850

  17. METACOGNITIVE SCAFFOLDS IMPROVE SELF-JUDGMENTS OF ACCURACY IN A MEDICAL INTELLIGENT TUTORING SYSTEM.

    PubMed

    Feyzi-Behnagh, Reza; Azevedo, Roger; Legowski, Elizabeth; Reitmeyer, Kayse; Tseytlin, Eugene; Crowley, Rebecca S

    2014-03-01

    In this study, we examined the effect of two metacognitive scaffolds on the accuracy of confidence judgments made while diagnosing dermatopathology slides in SlideTutor. Thirty-one ( N = 31) first- to fourth-year pathology and dermatology residents were randomly assigned to one of the two scaffolding conditions. The cases used in this study were selected from the domain of Nodular and Diffuse Dermatitides. Both groups worked with a version of SlideTutor that provided immediate feedback on their actions for two hours before proceeding to solve cases in either the Considering Alternatives or Playback condition. No immediate feedback was provided on actions performed by participants in the scaffolding mode. Measurements included learning gains (pre-test and post-test), as well as metacognitive performance, including Goodman-Kruskal Gamma correlation, bias, and discrimination. Results showed that participants in both conditions improved significantly in terms of their diagnostic scores from pre-test to post-test. More importantly, participants in the Considering Alternatives condition outperformed those in the Playback condition in the accuracy of their confidence judgments and the discrimination of the correctness of their assertions while solving cases. The results suggested that presenting participants with their diagnostic decision paths and highlighting correct and incorrect paths helps them to become more metacognitively accurate in their confidence judgments.

  18. How a GNSS Receiver Is Held May Affect Static Horizontal Position Accuracy

    PubMed Central

    Weaver, Steven A.; Ucar, Zennure; Bettinger, Pete; Merry, Krista

    2015-01-01

    The static horizontal position accuracy of a mapping-grade GNSS receiver was tested in two forest types over two seasons, and subsequently was tested in one forest type against open sky conditions in the winter season. The main objective was to determine whether the holding position during data collection would result in significantly different static horizontal position accuracy. Additionally, we wanted to determine whether the time of year (season), forest type, or environmental variables had an influence on accuracy. In general, the F4Devices Flint GNSS receiver was found to have mean static horizontal position accuracy levels within the ranges typically expected for this general type of receiver (3 to 5 m) when differential correction was not employed. When used under forest cover, in some cases the GNSS receiver provided a higher level of static horizontal position accuracy when held vertically, as opposed to held at an angle or horizontally (the more natural positions), perhaps due to the orientation of the antenna within the receiver, or in part due to multipath or the inability to use certain satellite signals. Therefore, due to the fact that numerous variables may affect static horizontal position accuracy, we only conclude that there is weak to moderate evidence that the results of holding position are significant. Statistical test results also suggest that the season of data collection had no significant effect on static horizontal position accuracy, and results suggest that atmospheric variables had weak correlation with horizontal position accuracy. Forest type was found to have a significant effect on static horizontal position accuracy in one aspect of one test, yet otherwise there was little evidence that forest type affected horizontal position accuracy. Since the holding position was found in some cases to be significant with regard to the static horizontal position accuracy of positions collected in forests, it may be beneficial to have an understanding of antenna positioning within the receiver to achieve the greatest accuracy during data collection. PMID:25923667

  19. How a GNSS Receiver Is Held May Affect Static Horizontal Position Accuracy.

    PubMed

    Weaver, Steven A; Ucar, Zennure; Bettinger, Pete; Merry, Krista

    2015-01-01

    The static horizontal position accuracy of a mapping-grade GNSS receiver was tested in two forest types over two seasons, and subsequently was tested in one forest type against open sky conditions in the winter season. The main objective was to determine whether the holding position during data collection would result in significantly different static horizontal position accuracy. Additionally, we wanted to determine whether the time of year (season), forest type, or environmental variables had an influence on accuracy. In general, the F4Devices Flint GNSS receiver was found to have mean static horizontal position accuracy levels within the ranges typically expected for this general type of receiver (3 to 5 m) when differential correction was not employed. When used under forest cover, in some cases the GNSS receiver provided a higher level of static horizontal position accuracy when held vertically, as opposed to held at an angle or horizontally (the more natural positions), perhaps due to the orientation of the antenna within the receiver, or in part due to multipath or the inability to use certain satellite signals. Therefore, due to the fact that numerous variables may affect static horizontal position accuracy, we only conclude that there is weak to moderate evidence that the results of holding position are significant. Statistical test results also suggest that the season of data collection had no significant effect on static horizontal position accuracy, and results suggest that atmospheric variables had weak correlation with horizontal position accuracy. Forest type was found to have a significant effect on static horizontal position accuracy in one aspect of one test, yet otherwise there was little evidence that forest type affected horizontal position accuracy. Since the holding position was found in some cases to be significant with regard to the static horizontal position accuracy of positions collected in forests, it may be beneficial to have an understanding of antenna positioning within the receiver to achieve the greatest accuracy during data collection.

  20. Pooled analysis of the accuracy of five cervical cancer screening tests assessed in eleven studies in Africa and India.

    PubMed

    Arbyn, Marc; Sankaranarayanan, Rengaswamy; Muwonge, Richard; Keita, Namory; Dolo, Amadou; Mbalawa, Charles Gombe; Nouhou, Hassan; Sakande, Boblewende; Wesley, Ramani; Somanathan, Thara; Sharma, Anjali; Shastri, Surendra; Basu, Parthasarathy

    2008-07-01

    Cervical cancer is the main cancer among women in sub-Saharan Africa, India and other parts of the developing world. Evaluation of screening performance of effective, feasible and affordable early detection and management methods is a public health priority. Five screening methods, naked eye visual inspection of the cervix uteri after application of diluted acetic acid (VIA), or Lugol's iodine (VILI) or with a magnifying device (VIAM), the Pap smear and human papillomavirus testing with the high-risk probe of the Hybrid Capture-2 assay (HC2), were evaluated in 11 studies in India and Africa. More than 58,000 women, aged 25-64 years, were tested with 2-5 screening tests and outcome verification was done on all women independent of the screen test results. The outcome was presence or absence of cervical intraepithelial neoplasia (CIN) of different degrees or invasive cervical cancer. Verification was based on colposcopy and histological interpretation of colposcopy-directed biopsies. Negative colposcopy was accepted as a truly negative outcome. VIA showed a sensitivity of 79% (95% CI 73-85%) and 83% (95% CI 77-89%), and a specificity of 85% (95% CI 81-89%) and 84% (95% CI 80-88%) for the outcomes CIN2+ or CIN3+, respectively. VILI was on average 10% more sensitive and equally specific. VIAM showed similar results as VIA. The Pap smear showed lowest sensitivity, even at the lowest cutoff of atypical squamous cells of undetermined significance (57%; 95% CI 38-76%) for CIN2+ but the specificity was rather high (93%; 95% CI 89-97%). The HC2-assay showed a sensitivity for CIN2+ of 62% (95% CI 56-68%) and a specificity of 94% (95% CI 92-95%). Substantial interstudy variation was observed in the accuracy of the visual screening methods. Accuracy of visual methods and cytology increased over time, whereas performance of HC2 was constant. Results of visual tests and colposcopy were highly correlated. This study was the largest ever done that evaluates the cross-sectional accuracy of screening tests for cervical cancer precursors in developing countries. The merit of the study was that all screened subjects were submitted to confirmatory investigations avoiding to verification bias. A major finding was the consistently higher sensitivity but equal specificity of VILI compared with VIA. Nevertheless, some caution is warranted in the interpretation of observed accuracy measures, since a certain degree of gold standard misclassification cannot be excluded. Because of the correlation between visual screening tests and colposcopy and a certain degree of over-diagnosis of apparent CIN2+ by study pathologists, it is possible that both sensitivity and specificity of VIA and VILI were overestimated. Gold standard verification error could also explain the surprisingly low sensitivity of HC2, which contrasts with findings from other studies. (c) 2008 Wiley-Liss, Inc.

  1. Assessing English Language Learners' Oral Performance: A Comparison of Monologue, Interview, and Group Oral Test

    ERIC Educational Resources Information Center

    Ahmadi, Alireza; Sadeghi, Elham

    2016-01-01

    In the present study we investigated the effect of test format on oral performance in terms of test scores and discourse features (accuracy, fluency, and complexity). Moreover, we explored how the scores obtained on different test formats relate to such features. To this end, 23 Iranian EFL learners participated in three test formats of monologue,…

  2. Enhancing Predictive Accuracy of Cardiac Autonomic Neuropathy Using Blood Biochemistry Features and Iterative Multitier Ensembles.

    PubMed

    Abawajy, Jemal; Kelarev, Andrei; Chowdhury, Morshed U; Jelinek, Herbert F

    2016-01-01

    Blood biochemistry attributes form an important class of tests, routinely collected several times per year for many patients with diabetes. The objective of this study is to investigate the role of blood biochemistry for improving the predictive accuracy of the diagnosis of cardiac autonomic neuropathy (CAN) progression. Blood biochemistry contributes to CAN, and so it is a causative factor that can provide additional power for the diagnosis of CAN especially in the absence of a complete set of Ewing tests. We introduce automated iterative multitier ensembles (AIME) and investigate their performance in comparison to base classifiers and standard ensemble classifiers for blood biochemistry attributes. AIME incorporate diverse ensembles into several tiers simultaneously and combine them into one automatically generated integrated system so that one ensemble acts as an integral part of another ensemble. We carried out extensive experimental analysis using large datasets from the diabetes screening research initiative (DiScRi) project. The results of our experiments show that several blood biochemistry attributes can be used to supplement the Ewing battery for the detection of CAN in situations where one or more of the Ewing tests cannot be completed because of the individual difficulties faced by each patient in performing the tests. The results show that AIME provide higher accuracy as a multitier CAN classification paradigm. The best predictive accuracy of 99.57% has been obtained by the AIME combining decorate on top tier with bagging on middle tier based on random forest. Practitioners can use these findings to increase the accuracy of CAN diagnosis.

  3. Investigations of interference between electromagnetic transponders and wireless MOSFET dosimeters: A phantom study

    PubMed Central

    Su, Zhong; Zhang, Lisha; Ramakrishnan, V.; Hagan, Michael; Anscher, Mitchell

    2011-01-01

    Purpose: To evaluate both the Calypso Systems’ (Calypso Medical Technologies, Inc., Seattle, WA) localization accuracy in the presence of wireless metal–oxide–semiconductor field-effect transistor (MOSFET) dosimeters of dose verification system (DVS, Sicel Technologies, Inc., Morrisville, NC) and the dosimeters’ reading accuracy in the presence of wireless electromagnetic transponders inside a phantom.Methods: A custom-made, solid-water phantom was fabricated with space for transponders and dosimeters. Two inserts were machined with positioning grooves precisely matching the dimensions of the transponders and dosimeters and were arranged in orthogonal and parallel orientations, respectively. To test the transponder localization accuracy with∕without presence of dosimeters (hypothesis 1), multivariate analyses were performed on transponder-derived localization data with and without dosimeters at each preset distance to detect statistically significant localization differences between the control and test sets. To test dosimeter dose-reading accuracy with∕without presence of transponders (hypothesis 2), an approach of alternating the transponder presence in seven identical fraction dose (100 cGy) deliveries and measurements was implemented. Two-way analysis of variance was performed to examine statistically significant dose-reading differences between the two groups and the different fractions. A relative-dose analysis method was also used to evaluate transponder impact on dose-reading accuracy after dose-fading effect was removed by a second-order polynomial fit.Results: Multivariate analysis indicated that hypothesis 1 was false; there was a statistically significant difference between the localization data from the control and test sets. However, the upper and lower bounds of the 95% confidence intervals of the localized positional differences between the control and test sets were less than 0.1 mm, which was significantly smaller than the minimum clinical localization resolution of 0.5 mm. For hypothesis 2, analysis of variance indicated that there was no statistically significant difference between the dosimeter readings with and without the presence of transponders. Both orthogonal and parallel configurations had difference of polynomial-fit dose to measured dose values within 1.75%.Conclusions: The phantom study indicated that the Calypso System’s localization accuracy was not affected clinically due to the presence of DVS wireless MOSFET dosimeters and the dosimeter-measured doses were not affected by the presence of transponders. Thus, the same patients could be implanted with both transponders and dosimeters to benefit from improved accuracy of radiotherapy treatments offered by conjunctional use of the two systems. PMID:21776780

  4. Sleep restriction and serving accuracy in performance tennis players, and effects of caffeine.

    PubMed

    Reyner, L A; Horne, J A

    2013-08-15

    Athletes often lose sleep on the night before a competition. Whilst it is unlikely that sleep loss will impair sports mostly relying on strength and endurance, little is known about potential effects on sports involving psychomotor performance necessitating judgement and accuracy, rather than speed, as in tennis for example, and where caffeine is 'permitted'. Two studies were undertaken, on 5h sleep (33%) restriction versus normal sleep, on serving accuracy in semi-professional tennis players. Testing (14:00 h-16:00 h) comprised 40 serves into a (1.8 m×1.1 m) 'service box' diagonally, over the net. Study 1 (8 m; 8 f) was within-Ss, counterbalanced (normal versus sleep restriction). Study 2 (6m;6f -different Ss) comprised three conditions (Latin square), identical to Study 1, except for an extra sleep restriction condition with 80 mg caffeine vs placebo in a sugar-free drink, given (double blind), 30 min before testing. Both studies showed significant impairments to serving accuracy after sleep restriction. Caffeine at this dose had no beneficial effect. Study 1 also assessed gender differences, with women significantly poorer under all conditions, and non-significant indications that women were more impaired by sleep restriction (also seen in Study 2). We conclude that adequate sleep is essential for best performance of this type of skill in tennis players and that caffeine is no substitute for 'lost sleep'. 210. © 2013.

  5. (LMRG): Microscope Resolution, Objective Quality, Spectral Accuracy and Spectral Un-mixing

    PubMed Central

    Bayles, Carol J.; Cole, Richard W.; Eason, Brady; Girard, Anne-Marie; Jinadasa, Tushare; Martin, Karen; McNamara, George; Opansky, Cynthia; Schulz, Katherine; Thibault, Marc; Brown, Claire M.

    2012-01-01

    The second study by the LMRG focuses on measuring confocal laser scanning microscope (CLSM) resolution, objective lens quality, spectral imaging accuracy and spectral un-mixing. Affordable test samples for each aspect of the study were designed, prepared and sent to 116 labs from 23 countries across the globe. Detailed protocols were designed for the three tests and customized for most of the major confocal instruments being used by the study participants. One protocol developed for measuring resolution and objective quality was recently published in Nature Protocols (Cole, R. W., T. Jinadasa, et al. (2011). Nature Protocols 6(12): 1929–1941). The first study involved 3D imaging of sub-resolution fluorescent microspheres to determine the microscope point spread function. Results of the resolution studies as well as point spread function quality (i.e. objective lens quality) from 140 different objective lenses will be presented. The second study of spectral accuracy looked at the reflection of the laser excitation lines into the spectral detection in order to determine the accuracy of these systems to report back the accurate laser emission wavelengths. Results will be presented from 42 different spectral confocal systems. Finally, samples with double orange beads (orange core and orange coating) were imaged spectrally and the imaging software was used to un-mix fluorescence signals from the two orange dyes. Results from 26 different confocal systems will be summarized. Time will be left to discuss possibilities for the next LMRG study.

  6. The Impact of Pushed Output on Accuracy and Fluency of Iranian EFL Learners' Speaking

    ERIC Educational Resources Information Center

    Sadeghi Beniss, Aram Reza; Edalati Bazzaz, Vahid

    2014-01-01

    The current study attempted to establish baseline quantitative data on the impacts of pushed output on two components of speaking (i.e., accuracy and fluency). To achieve this purpose, 30 female EFL learners were selected from a whole population pool of 50 based on the standard test of IELTS interview and were randomly assigned into an…

  7. Effects of Stimulus Octave and Timbre on the Tuning Accuracy of Advanced College Instrumentalists

    ERIC Educational Resources Information Center

    Byo, James L.; Schlegel, Amanda L.

    2016-01-01

    The purpose of this study was to test the effects of octave and timbre on advanced college musicians' (N = 63) ability to tune their instruments. We asked: "Are there differences in tuning accuracy due to octave (B-flat 2, B-flat 4) and stimulus timbre (oboe, clarinet, electronic tuner, tuba)?" and "To what extent do participants'…

  8. Predictive Utility and Classification Accuracy of Oral Reading Fluency and the Measures of Academic Progress for the Wisconsin Knowledge and Concepts Exam

    ERIC Educational Resources Information Center

    Ball, Carrie R.; O'Connor, Edward

    2016-01-01

    This study examined the predictive validity and classification accuracy of two commonly used universal screening measures relative to a statewide achievement test. Results indicated that second-grade performance on oral reading fluency and the Measures of Academic Progress (MAP), together with special education status, explained 68% of the…

  9. Accuracy and Variability of Item Parameter Estimates from Marginal Maximum a Posteriori Estimation and Bayesian Inference via Gibbs Samplers

    ERIC Educational Resources Information Center

    Wu, Yi-Fang

    2015-01-01

    Item response theory (IRT) uses a family of statistical models for estimating stable characteristics of items and examinees and defining how these characteristics interact in describing item and test performance. With a focus on the three-parameter logistic IRT (Birnbaum, 1968; Lord, 1980) model, the current study examines the accuracy and…

  10. Evaluation of a Home Biomonitoring Autonomous Mobile Robot.

    PubMed

    Dorronzoro Zubiete, Enrique; Nakahata, Keigo; Imamoglu, Nevrez; Sekine, Masashi; Sun, Guanghao; Gomez, Isabel; Yu, Wenwei

    2016-01-01

    Increasing population age demands more services in healthcare domain. It has been shown that mobile robots could be a potential solution to home biomonitoring for the elderly. Through our previous studies, a mobile robot system that is able to track a subject and identify his daily living activities has been developed. However, the system has not been tested in any home living scenarios. In this study we did a series of experiments to investigate the accuracy of activity recognition of the mobile robot in a home living scenario. The daily activities tested in the evaluation experiment include watching TV and sleeping. A dataset recorded by a distributed distance-measuring sensor network was used as a reference to the activity recognition results. It was shown that the accuracy is not consistent for all the activities; that is, mobile robot could achieve a high success rate in some activities but a poor success rate in others. It was found that the observation position of the mobile robot and subject surroundings have high impact on the accuracy of the activity recognition, due to the variability of the home living daily activities and their transitional process. The possibility of improvement of recognition accuracy has been shown too.

  11. Intelligent Diagnostic Assistant for Complicated Skin Diseases through C5's Algorithm.

    PubMed

    Jeddi, Fatemeh Rangraz; Arabfard, Masoud; Kermany, Zahra Arab

    2017-09-01

    Intelligent Diagnostic Assistant can be used for complicated diagnosis of skin diseases, which are among the most common causes of disability. The aim of this study was to design and implement a computerized intelligent diagnostic assistant for complicated skin diseases through C5's Algorithm. An applied-developmental study was done in 2015. Knowledge base was developed based on interviews with dermatologists through questionnaires and checklists. Knowledge representation was obtained from the train data in the database using Excel Microsoft Office. Clementine Software and C5's Algorithms were applied to draw the decision tree. Analysis of test accuracy was performed based on rules extracted using inference chains. The rules extracted from the decision tree were entered into the CLIPS programming environment and the intelligent diagnostic assistant was designed then. The rules were defined using forward chaining inference technique and were entered into Clips programming environment as RULE. The accuracy and error rates obtained in the training phase from the decision tree were 99.56% and 0.44%, respectively. The accuracy of the decision tree was 98% and the error was 2% in the test phase. Intelligent diagnostic assistant can be used as a reliable system with high accuracy, sensitivity, specificity, and agreement.

  12. Method for digital measurement of phase-frequency characteristics for a fixed-length ultrasonic spectrometer

    NASA Astrophysics Data System (ADS)

    Astashev, M. E.; Belosludtsev, K. N.; Kharakoz, D. P.

    2014-05-01

    One of the most accurate methods for measuring the compressibility of liquids is resonance measurement of sound velocity in a fixed-length interferometer. This method combines high sensitivity, accuracy, and small sample volume of the test liquid. The measuring principle is to study the resonance properties of a composite resonator that contains a test liquid sample. Ealier, the phase-locked loop (PLL) scheme was used for this. In this paper, we propose an alternative measurement scheme based on digital analysis of harmonic signals, describe the implementation of this scheme using commercially available data acquisition modules, and give examples of test measurements with accuracy evaluations of the results.

  13. An Approach towards Ultrasound Kidney Cysts Detection using Vector Graphic Image Analysis

    NASA Astrophysics Data System (ADS)

    Mahmud, Wan Mahani Hafizah Wan; Supriyanto, Eko

    2017-08-01

    This study develops new approach towards detection of kidney ultrasound image for both with single cyst as well as multiple cysts. 50 single cyst images and 25 multiple cysts images were used to test the developed algorithm. Steps involved in developing this algorithm were vector graphic image formation and analysis, thresholding, binarization, filtering as well as roundness test. Performance evaluation to 50 single cyst images gave accuracy of 92%, while for multiple cysts images, the accuracy was about 86.89% when tested to 25 multiple cysts images. This developed algorithm may be used in developing a computerized system such as computer aided diagnosis system to help medical experts in diagnosis of kidney cysts.

  14. Assessing the Accuracy of Passive Microwave Estimates of Snow Water Equivalent in Data-Scarce Regions for Use in Water Resource Applications: A Case Study in the Upper Helmand Watershed, Afghanistan

    DTIC Science & Technology

    2011-03-01

    to remotely sensed SCA and SWE. The first analysis, a comparison to SCA imagery, tests the models ability to correctly estimate the snow extent...remotely sensed data (Con- galton and Green 2009). The producer’s accuracies consistently show the model underestimating the snow extent at the end...and K. Green. 2009. Assessing the accuracy of remotely sensed data: principals and practices, Second edition. CRC Press, Taylor & Francis Group

  15. Radiological interpretation of images displayed on tablet computers: a systematic review.

    PubMed

    Caffery, L J; Armfield, N R; Smith, A C

    2015-06-01

    To review the published evidence and to determine if radiological diagnostic accuracy is compromised when images are displayed on a tablet computer and thereby inform practice on using tablet computers for radiological interpretation by on-call radiologists. We searched the PubMed and EMBASE databases for studies on the diagnostic accuracy or diagnostic reliability of images interpreted on tablet computers. Studies were screened for inclusion based on pre-determined inclusion and exclusion criteria. Studies were assessed for quality and risk of bias using Quality Appraisal of Diagnostic Reliability Studies or the revised Quality Assessment of Diagnostic Accuracy Studies tool. Treatment of studies was reported according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). 11 studies met the inclusion criteria. 10 of these studies tested the Apple iPad(®) (Apple, Cupertino, CA). The included studies reported high sensitivity (84-98%), specificity (74-100%) and accuracy rates (98-100%) for radiological diagnosis. There was no statistically significant difference in accuracy between a tablet computer and a digital imaging and communication in medicine-calibrated control display. There was a near complete consensus from authors on the non-inferiority of diagnostic accuracy of images displayed on a tablet computer. All of the included studies were judged to be at risk of bias. Our findings suggest that the diagnostic accuracy of radiological interpretation is not compromised by using a tablet computer. This result is only relevant to the Apple iPad and to the modalities of CT, MRI and plain radiography. The iPad may be appropriate for an on-call radiologist to use for radiological interpretation.

  16. Detection and mapping the spatial distribution of bracken fern weeds using the Landsat 8 OLI new generation sensor

    NASA Astrophysics Data System (ADS)

    Matongera, Trylee Nyasha; Mutanga, Onisimo; Dube, Timothy; Sibanda, Mbulisi

    2017-05-01

    Bracken fern is an invasive plant that presents serious environmental, ecological and economic problems around the world. An understanding of the spatial distribution of bracken fern weeds is therefore essential for providing appropriate management strategies at both local and regional scales. The aim of this study was to assess the utility of the freely available medium resolution Landsat 8 OLI sensor in the detection and mapping of bracken fern at the Cathedral Peak, South Africa. To achieve this objective, the results obtained from Landsat 8 OLI were compared with those derived using the costly, high spatial resolution WorldView-2 imagery. Since previous studies have already successfully mapped bracken fern using high spatial resolution WorldView-2 image, the comparison was done to investigate the magnitude of difference in accuracy between the two sensors in relation to their acquisition costs. To evaluate the performance of Landsat 8 OLI in discriminating bracken fern compared to that of Worldview-2, we tested the utility of (i) spectral bands; (ii) derived vegetation indices as well as (iii) the combination of spectral bands and vegetation indices based on discriminant analysis classification algorithm. After resampling the training and testing data and reclassifying several times (n = 100) based on the combined data sets, the overall accuracies for both Landsat 8 and WorldView-2 were tested for significant differences based on Mann-Whitney U test. The results showed that the integration of the spectral bands and derived vegetation indices yielded the best overall classification accuracy (80.08% and 87.80% for Landsat 8 OLI and WorldView-2 respectively). Additionally, the use of derived vegetation indices as a standalone data set produced the weakest overall accuracy results of 62.14% and 82.11% for both the Landsat 8 OLI and WorldView-2 images. There were significant differences {U (100) = 569.5, z = -10.8242, p < 0.01} between the classification accuracies derived based on Landsat OLI 8 and those derived using WorldView-2 sensor. Although there were significant differences between Landsat and WorldView-2 accuracies, the magnitude of variation (9%) between the two sensors was within an acceptable range. Therefore, the findings of this study demonstrated that the recently launched Landsat 8 OLI multispectral sensor provides valuable information that could aid in the long term continuous monitoring and formulation of effective bracken fern management with acceptable accuracies that are comparable to those obtained from the high resolution WorldView-2 commercial sensor.

  17. Accuracy of parasitological and immunological tests for the screening of human schistosomiasis in immigrants and refugees from African countries: An approach with Latent Class Analysis

    PubMed Central

    Beltrame, Anna; Guerriero, Massimo; Angheben, Andrea; Gobbi, Federico; Requena-Mendez, Ana; Zammarchi, Lorenzo; Formenti, Fabio; Perandin, Francesca; Bisoffi, Zeno

    2017-01-01

    Background Schistosomiasis is a neglected infection affecting millions of people, mostly living in sub-Saharan Africa. Morbidity and mortality due to chronic infection are relevant, although schistosomiasis is often clinically silent. Different diagnostic tests have been implemented in order to improve screening and diagnosis, that traditionally rely on parasitological tests with low sensitivity. Aim of this study was to evaluate the accuracy of different tests for the screening of schistosomiasis in African migrants, in a non endemic setting. Methodology/Principal findings A retrospective study was conducted on 373 patients screened at the Centre for Tropical Diseases (CTD) in Negrar, Verona, Italy. Biological samples were tested with: stool/urine microscopy, Circulating Cathodic Antigen (CCA) dipstick test, ELISA, Western blot, immune-chromatographic test (ICT). Test accuracy and predictive values of the immunological tests were assessed primarily on the basis of the results of microscopy (primary reference standard): ICT and WB resulted the test with highest sensitivity (94% and 92%, respectively), with a high NPV (98%). CCA showed the highest specificity (93%), but low sensitivity (48%). The analysis was conducted also using a composite reference standard, CRS (patients classified as infected in case of positive microscopy and/or at least 2 concordant positive immunological tests) and Latent Class Analysis (LCA). The latter two models demonstrated excellent agreement (Cohen’s kappa: 0.92) for the classification of the results. In fact, they both confirmed ICT as the test with the highest sensitivity (96%) and NPV (97%), moreover PPV was reasonably good (78% and 72% according to CRS and LCA, respectively). ELISA resulted the most specific immunological test (over 99%). The ICT appears to be a suitable screening test, even when used alone. Conclusions The rapid test ICT was the most sensitive test, with the potential of being used as a single screening test for African migrants. PMID:28582412

  18. 40 CFR 63.8 - Monitoring requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... with conducting performance tests under § 63.7. Verification of operational status shall, at a minimum... in the relevant standard; or (B) The CMS fails a performance test audit (e.g., cylinder gas audit), relative accuracy audit, relative accuracy test audit, or linearity test audit; or (C) The COMS CD exceeds...

  19. 40 CFR 63.8 - Monitoring requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... with conducting performance tests under § 63.7. Verification of operational status shall, at a minimum... in the relevant standard; or (B) The CMS fails a performance test audit (e.g., cylinder gas audit), relative accuracy audit, relative accuracy test audit, or linearity test audit; or (C) The COMS CD exceeds...

  20. The diagnostic accuracy and outcomes after coronary computed tomography angiography vs. conventional functional testing in patients with stable angina pectoris: a systematic review and meta-analysis.

    PubMed

    Nielsen, Lene H; Ortner, Nino; Nørgaard, Bjarne L; Achenbach, Stephan; Leipsic, Jonathon; Abdulla, Jawdat

    2014-09-01

    To systematically review and perform a meta-analysis of the diagnostic accuracy and post-test outcomes of conventional exercise electrocardiography (XECG) and single-photon emission computed tomography (SPECT) compared with coronary computed tomography angiography (coronary CTA) in patients suspected of stable coronary artery disease (CAD). We systematically searched for studies published from January 2002 to February 2013 examining the diagnostic accuracy (defined as at least ≥50% luminal obstruction on invasive coronary angiography) and outcomes of coronary CTA (≥16 slice) in comparison with XECG and SPECT. The search revealed 11 eligible studies (N = 1575) comparing the diagnostic accuracy and 7 studies (N = 216.603) the outcomes of coronary CTA vs. XECG or/and SPECT. The per-patient sensitivity [95% confidence interval (95% CI)] to identify significant CAD was 98% (93-99%) for coronary CTA vs. 67% (54-78%) (P < 0.001) for XECG and 99% (96-100%) vs. 73% (59-83%) (P = 0.001) for SPECT. The specificity (95% CI) of coronary CTA was 82% (63-93%) vs. 46% (30-64%) (P < 0.001) for XECG and 71% (60-80%) vs. 48% (31-64%) (P = 0.14) for SPECT. The odds ratio (OR) of downstream test utilization (DTU) for coronary CTA vs. XECG/SPECT was 1.38 (1.33-1.43, P < 0.001), for revascularization 2.63 (2.50-2.77, P < 0.001), for non-fatal myocardial infarction 0.53 (0.39-0.72, P < 0.001), and for all-cause mortality 1.01 (0.87-1.18, P = 0.87). The up-front diagnostic performance of coronary CTA is higher than of XECG and SPECT. When compared with XECG/SPECT testing, coronary CTA testing is associated with increased DTU and coronary revascularization. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  1. Modeling Student Test-Taking Motivation in the Context of an Adaptive Achievement Test

    ERIC Educational Resources Information Center

    Wise, Steven L.; Kingsbury, G. Gage

    2016-01-01

    This study examined the utility of response time-based analyses in understanding the behavior of unmotivated test takers. For the data from an adaptive achievement test, patterns of observed rapid-guessing behavior and item response accuracy were compared to the behavior expected under several types of models that have been proposed to represent…

  2. The Childhood Asperger Syndrome Test (CAST): Test-Retest Reliability in a High Scoring Sample

    ERIC Educational Resources Information Center

    Allison, Carrie; Williams, Jo; Scott, Fiona; Stott, Carol; Bolton, Patrick; Baron-Cohen, Simon; Brayne, Carol

    2007-01-01

    The Childhood Asperger Syndrome Test (CAST) is a 37-item parental self-completion questionnaire designed to screen for high-functioning autism spectrum conditions in epidemiological research. The CAST has previously demonstrated good accuracy for use as a screening test, with high sensitivity in studies with primary school aged children in…

  3. How Big Is Big Enough? Sample Size Requirements for CAST Item Parameter Estimation

    ERIC Educational Resources Information Center

    Chuah, Siang Chee; Drasgow, Fritz; Luecht, Richard

    2006-01-01

    Adaptive tests offer the advantages of reduced test length and increased accuracy in ability estimation. However, adaptive tests require large pools of precalibrated items. This study looks at the development of an item pool for 1 type of adaptive administration: the computer-adaptive sequential test. An important issue is the sample size required…

  4. Comparison of seven protocols to identify fecal contamination sources using Escherichia coli

    USGS Publications Warehouse

    Stoeckel, D.M.; Mathes, M.V.; Hyer, K.E.; Hagedorn, C.; Kator, H.; Lukasik, J.; O'Brien, T. L.; Fenger, T.W.; Samadpour, M.; Strickler, K.M.; Wiggins, B.A.

    2004-01-01

    Microbial source tracking (MST) uses various approaches to classify fecal-indicator microorganisms to source hosts. Reproducibility, accuracy, and robustness of seven phenotypic and genotypic MST protocols were evaluated by use of Escherichia coli from an eight-host library of known-source isolates and a separate, blinded challenge library. In reproducibility tests, measuring each protocol's ability to reclassify blinded replicates, only one (pulsed-field gel electrophoresis; PFGE) correctly classified all test replicates to host species; three protocols classified 48-62% correctly, and the remaining three classified fewer than 25% correctly. In accuracy tests, measuring each protocol's ability to correctly classify new isolates, ribotyping with EcoRI and PvuII approached 100% correct classification but only 6% of isolates were classified; four of the other six protocols (antibiotic resistance analysis, PFGE, and two repetitive-element PCR protocols) achieved better than random accuracy rates when 30-100% of challenge isolates were classified. In robustness tests, measuring each protocol's ability to recognize isolates from nonlibrary hosts, three protocols correctly classified 33-100% of isolates as "unknown origin," whereas four protocols classified all isolates to a source category. A relevance test, summarizing interpretations for a hypothetical water sample containing 30 challenge isolates, indicated that false-positive classifications would hinder interpretations for most protocols. Study results indicate that more representation in known-source libraries and better classification accuracy would be needed before field application. Thorough reliability assessment of classification results is crucial before and during application of MST protocols.

  5. Accuracy assessment of a mobile terrestrial lidar survey at Padre Island National Seashore

    USGS Publications Warehouse

    Lim, Samsung; Thatcher, Cindy A.; Brock, John C.; Kimbrow, Dustin R.; Danielson, Jeffrey J.; Reynolds, B.J.

    2013-01-01

    The higher point density and mobility of terrestrial laser scanning (light detection and ranging (lidar)) is desired when extremely detailed elevation data are needed for mapping vertically orientated complex features such as levees, dunes, and cliffs, or when highly accurate data are needed for monitoring geomorphic changes. Mobile terrestrial lidar scanners have the capability for rapid data collection on a larger spatial scale compared with tripod-based terrestrial lidar, but few studies have examined the accuracy of this relatively new mapping technology. For this reason, we conducted a field test at Padre Island National Seashore of a mobile lidar scanner mounted on a sport utility vehicle and integrated with a position and orientation system. The purpose of the study was to assess the vertical and horizontal accuracy of data collected by the mobile terrestrial lidar system, which is georeferenced to the Universal Transverse Mercator coordinate system and the North American Vertical Datum of 1988. To accomplish the study objectives, independent elevation data were collected by conducting a high-accuracy global positioning system survey to establish the coordinates and elevations of 12 targets spaced throughout the 12 km transect. These independent ground control data were compared to the lidar scanner-derived elevations to quantify the accuracy of the mobile lidar system. The performance of the mobile lidar system was also tested at various vehicle speeds and scan density settings (e.g. field of view and linear point spacing) to estimate the optimal parameters for desired point density. After adjustment of the lever arm parameters, the final point cloud accuracy was 0.060 m (east), 0.095 m (north), and 0.053 m (height). The very high density of the resulting point cloud was sufficient to map fine-scale topographic features, such as the complex shape of the sand dunes.

  6. Accuracy of maxillary positioning after standard and inverted orthognathic sequencing.

    PubMed

    Ritto, Fabio G; Ritto, Thiago G; Ribeiro, Danilo Passeado; Medeiros, Paulo José; de Moraes, Márcio

    2014-05-01

    This study aimed to compare the accuracy of maxillary positioning after bimaxillary orthognathic surgery, using 2 sequences. A total of 80 cephalograms (40 preoperative and 40 postoperative) from 40 patients were analyzed. Group 1 included radiographs of patients submitted to conventional sequence, whereas group 2 patients were submitted to inverted sequence. The final position of the maxillary central incisor was obtained after vertical and horizontal measurements of the tracings, and it was compared with what had been planned. The null hypothesis, which stated that there would be no difference between the groups, was tested. After applying the Welch t test for comparison of mean differences between maxillary desired and achieved position, considering a statistical significance of 5% and a 2-tailed test, the null hypothesis was not rejected (P > .05). Thus, there was no difference in the accuracy of maxillary positioning between groups. Conventional and inverted sequencing proved to be reliable in positioning the maxilla after LeFort I osteotomy in bimaxillary orthognathic surgeries. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Validity of wearable activity monitors for tracking steps and estimating energy expenditure during a graded maximal treadmill test.

    PubMed

    Kendall, Bradley; Bellovary, Bryanne; Gothe, Neha P

    2018-06-04

    The purpose of this study was to assess the accuracy of energy expenditure (EE) estimation and step tracking abilities of six activity monitors (AMs) in relation to indirect calorimetry and hand counted steps and assess the accuracy of the AMs between high and low fit individuals in order to assess the impact of exercise intensity. Fifty participants wore the Basis watch, Fitbit Flex, Polar FT7, Jawbone, Omron pedometer, and Actigraph during a maximal graded treadmill test. Correlations, intra-class correlations, and t-tests determined accuracy and agreement between AMs and criterions. The results indicate that the Omron, Fitbit, and Actigraph were accurate for measuring steps while the Basis and Jawbone significantly underestimated steps. All AMs were significantly correlated with indirect calorimetry, however, no devices showed agreement (p < .05). When comparing low and high fit groups, correlations between AMs and indirect calorimetry improved for the low fit group, suggesting AMs may be better at measuring EE at lower intensity exercise.

  8. The MRIS feasibility study

    NASA Technical Reports Server (NTRS)

    Neece, Robert T.; Cross, Aubrey E.; Schrader, James H.

    1993-01-01

    The Microwave Reflectometer Ionization Sensor (MRIS) is an instrument being developed for use in detecting and ranging of electron density layers in the reentry plasma of a space transfer vehicle. The rationale for the selection of the Double Sideband Suppressed Carrier (DSBSC) system used in the feasibility study for the MRIS is presented. A 25 GHz single-oscillator system and a 220 GHz double-oscillator system are described. The 25 GHz system was constructed and tested in the laboratory and test results are presented. As developed, the system employs a sideband spacing of 160 MHz. Based on an estimated electromagnetic wave velocity in the plasma, a round-trip phase shift measurement accuracy of +/- 7.6 degrees was required for the desired +/- 1/2 cm distance measurement accuracy. The interaction of parallel ground and reflecting planes produces interference that prevents the basic DSBSC system from meeting the accuracy goal so a frequency modulation was added to the system to allow averaging of the measured phase deviation. With an FM deviation of +/- 1 GHz, laboratory measurements were made for distances from 5 to 61 cm tip free space. Accounting for the plasma velocity factor, 82 percent of the data were equal to or better than the desired accuracy. Based on this measured result a sideband spacing to 250 MHz could be expected to yield data approximately 96 percent within the accuracy goal.

  9. Non-invasive diagnostic assessment tools for the detection of liver fibrosis in patients with suspected alcohol-related liver disease: a systematic review and economic evaluation.

    PubMed

    Stevenson, M; Lloyd-Jones, M; Morgan, M Y; Wong, R

    2012-01-01

    Excessive alcohol consumption may lead to the development of alcohol-related liver disease (ALD). Liver biopsy may be used in patients with suspected ALD to confirm the diagnosis, exclude other or additional liver pathologies, and provide accurate staging of the degree of liver injury in order to enable the prediction of prognosis and inform treatment decisions. However, as it is an invasive procedure that carries the risk of morbidity and mortality, current UK guidance recommends that biopsy is not required to confirm the diagnosis in patients with a high clinical suspicion of ALD in whom blood tests have excluded other causes of liver disease, unless it is necessary to confirm a diagnosis of acute alcoholic hepatitis in order to inform specific treatment decisions. To evaluate the diagnostic accuracy, cost-effectiveness, and effect on patient outcomes of four non-invasive tests for liver fibrosis [the Enhanced Liver Fibrosis (ELF™) test (Siemens Healthcare Diagnostic Inc., Tarrytown, NY, USA), FibroTest (BioPredictive, Paris, France), FibroMAX (BioPredictive, Paris, France) and transient elastography (FibroScan(®); produced by EchoSens, Paris, France and distributed in the UK by Artemis Medical Ltd, Kent, UK)] in patients suspected of having ALD. A systematic review was undertaken to identify studies reporting the diagnostic and prognostic accuracy of the ELF test, FibroTest, FibroMAX, and FibroScan for the identification of liver fibrosis and associated conditions in patients with suspected ALD. The following databases were searched in January 2010: MEDLINE (from 1950 to January 2010), MEDLINE In-Process & Other Non-Indexed Citations (from 1950 to January 2010), EMBASE (from 1980 to January 2010), Cochrane Database of Systematic Reviews (from 1996 to January 2010), Cochrane Central Register of Controlled Trials (from 1898 to January 2010), Cochrane Methodology Register (from 1904 to January 2010), Database of Abstracts of Reviews of Effects (from 1995 to January 2010), HTA Database (from 1995 to January 2010), NHS Economic Evaluation Database (from 1995 to January 2010), Cumulative Index to Nursing and Allied Health Literature (from 1982 to January 2010), Web of Knowledge and Science Citation Index (from 1969 to January 2010). Study quality was assessed using the QUADAS (Quality Assessment of Diagnostic Accuracy Studies) checklist. Owing to the heterogeneity of the studies, no formal meta-analysis was undertaken. A de novo mathematical model was constructed to estimate the incremental costs and incremental quality-adjusted life-years (QALYs) associated with alternative strategies compared with a biopsy-all strategy. The tests are assessed first as a replacement for liver biopsy, and secondly as an additional test prior to liver biopsy. Thirty-six scenarios were assessed for each non-invasive test strategy, which varied the sensitivity of biopsy, the anxiety associated with biopsy, sensitivity and specificity values and whether or not the biopsy was percutaneous or transjugular. For each scenario, threshold levels were reported where biopsying all patients was more cost-effective than the strategy for two parameters (the decreased level of abstinence associated with the strategy compared with biopsying all and the level of incidental QALY gain associated with biopsy). No studies were identified that specifically assessed the ELF test, although a study was identified that evaluated the diagnostic accuracy of the European Liver Fibrosis Test (essentially, the ELF test with the addition of age to the algorithm) compared with biopsy. Three studies of FibroTest, no relevant studies of FibroMax, and six studies of FibroScan assessing accuracy compared with biopsy in patients with known or suspected alcohol-related liver disease were identified. In all studies, the number of patients with suspected ALD was small, meaning that the estimated sensitivities and specificities were not robust. No conclusive estimate of the cost per QALY of each non-invasive test could be provided. Scenarios exist in which each of the strateg

  10. Predictive values of thermal and electrical dental pulp tests: a clinical study.

    PubMed

    Villa-Chávez, Carlos E; Patiño-Marín, Nuria; Loyola-Rodríguez, Juan P; Zavala-Alonso, Norma V; Martínez-Castañón, Gabriel A; Medina-Solís, Carlo E

    2013-08-01

    For a diagnostic test to be useful, it is necessary to determine the probability that the test will provide the correct diagnosis. Therefore, it is necessary to calculate the predictive value of diagnostics. The aim of the present study was to identify the sensitivity, specificity, positive and negative predictive values, accuracy, and reproducibility of thermal and electrical tests of pulp sensitivity. The thermal tests studied were the 1, 1, 1, 2-tetrafluoroethane (cold) and hot gutta-percha (hot) tests. For the electrical test, the Analytic Technology Pulp Tester (Analytic Technology, Redmond, WA) was used. A total of 110 teeth were tested: 60 teeth with vital pulp and 50 teeth with necrotic pulps (disease prevalence of 45%). The ideal standard was established by direct pulp inspection. The sensitivities of the diagnostic tests were 0.88 for the cold test, 0.86 for the heat test, and 0.76 for the electrical test, and the specificity was 1.0 for all 3 tests. The negative predictive value was 0.90 for the cold test, 0.89 for the heat test, and 0.83 for the electrical test, and the positive predictive value was 1.0 for all 3 tests. The highest accuracy (0.94) and reproducibility (0.88) were observed for the cold test. The cold test was the most accurate method for diagnostic testing. Copyright © 2013 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  11. Dimensional Accuracy of Hydrophilic and Hydrophobic VPS Impression Materials Using Different Impression Techniques - An Invitro Study

    PubMed Central

    Pilla, Ajai; Pathipaka, Suman

    2016-01-01

    Introduction The dimensional stability of the impression material could have an influence on the accuracy of the final restoration. Vinyl Polysiloxane Impression materials (VPS) are most frequently used as the impression material in fixed prosthodontics. As VPS is hydrophobic when it is poured with gypsum products, manufacturers added intrinsic surfactants and marketed as hydrophilic VPS. These hydrophilic VPS have shown increased wettability with gypsum slurries. VPS are available in different viscosities ranging from very low to very high for usage under different impression techniques. Aim To compare the dimensional accuracy of hydrophilic VPS and hydrophobic VPS using monophase, one step and two step putty wash impression techniques. Materials and Methods To test the dimensional accuracy of the impression materials a stainless steel die was fabricated as prescribed by ADA specification no. 19 for elastomeric impression materials. A total of 60 impressions were made. The materials were divided into two groups, Group1 hydrophilic VPS (Aquasil) and Group 2 hydrophobic VPS (Variotime). These were further divided into three subgroups A, B, C for monophase, one-step and two-step putty wash technique with 10 samples in each subgroup. The dimensional accuracy of the impressions was evaluated after 24 hours using vertical profile projector with lens magnification range of 20X-125X illumination. The study was analyzed through one-way ANOVA, post-hoc Tukey HSD test and unpaired t-test for mean comparison between groups. Results Results showed that the three different impression techniques (monophase, 1-step, 2-step putty wash techniques) did cause significant change in dimensional accuracy between hydrophilic VPS and hydrophobic VPS impression materials. One-way ANOVA disclosed, mean dimensional change and SD for hydrophilic VPS varied between 0.56% and 0.16%, which were low, suggesting hydrophilic VPS was satisfactory with all three impression techniques. However, mean dimensional change and SD for hydrophobic VPS were much higher with monophase, mere increase for 1-step and 2-step, than the standard steel die (p<0.05). Unpaired t-test displayed that hydrophilic VPS judged satisfactory compared to hydrophobic VPS among 1-step and 2-step impression technique. Conclusion Within the limitations of this study, it can be concluded that hydrophilic Vinyl polysiloxane was more dimensionally accurate than hydrophobic Vinyl polysiloxane using monophase, one step and two step putty wash impression techniques under moist conditions. PMID:27042587

  12. Accuracy Rates of Ancestry Estimation by Forensic Anthropologists Using Identified Forensic Cases.

    PubMed

    Thomas, Richard M; Parks, Connie L; Richard, Adam H

    2017-07-01

    A common task in forensic anthropology involves the estimation of the ancestry of a decedent by comparing their skeletal morphology and measurements to skeletons of individuals from known geographic groups. However, the accuracy rates of ancestry estimation methods in actual forensic casework have rarely been studied. This article uses 99 forensic cases with identified skeletal remains to develop accuracy rates for ancestry estimations conducted by forensic anthropologists. The overall rate of correct ancestry estimation from these cases is 90.9%, which is comparable to most research-derived rates and those reported by individual practitioners. Statistical tests showed no significant difference in accuracy rates depending on examiner education level or on the estimated or identified ancestry. More recent cases showed a significantly higher accuracy rate. The incorporation of metric analyses into the ancestry estimate in these cases led to a higher accuracy rate. © 2017 American Academy of Forensic Sciences.

  13. Validation of the standardized field sobriety test battery at BACs below 0.10 percent

    DOT National Transportation Integrated Search

    1998-08-01

    This study evaluated the accuracy of the National Highway Traffic Safety Administration's (NHTSA's) Standardized Field Sobriety Test (SFST) battery to assist officers in making arrest decisions for Driving While Intoxicated (DWI) at blood alcohol con...

  14. Accuracy of the Enhanced Liver Fibrosis Test vs FibroTest, Elastography, and Indirect Markers in Detection of Advanced Fibrosis in Patients With Alcoholic Liver Disease.

    PubMed

    Thiele, Maja; Madsen, Bjørn Stæhr; Hansen, Janne Fuglsang; Detlefsen, Sönke; Antonsen, Steen; Krag, Aleksander

    2018-04-01

    Alcohol is the leading cause of cirrhosis and liver-related mortality, but we lack serum markers to detect compensated disease. We compared the accuracy of the Enhanced Liver Fibrosis test (ELF), the FibroTest, liver stiffness measurements (made by transient elastography and 2-dimensional shear-wave elastography), and 6 indirect marker tests in detection of advanced liver fibrosis (Kleiner stage ≥F3). We performed a prospective study of 10 liver fibrosis markers (patented and not), all performed on the same day. Patients were recruited from primary centers (municipal alcohol rehabilitation, n = 128; 6% with advanced fibrosis) and secondary health care centers (hospital outpatient clinics, n = 161; 36% with advanced fibrosis) in the Region of Southern Denmark from 2013 through 2016. Biopsy-verified fibrosis stage was used as the reference standard. The primary aim was to validate ELF in detection of advanced fibrosis in patients with alcoholic liver disease recruited from primary and secondary health care centers, using the literature-based cutoff value of 10.5. Secondary aims were to assess the diagnostic accuracy of ELF for significant fibrosis and cirrhosis and to determine whether combinations of fibrosis markers increase diagnostic yield. The ELF identified patients with advanced liver fibrosis with an area under the receiver operating characteristic curve (AUROC) of 0.92 (95% confidence interval 0.89-0.96); findings did not differ significantly between patients from primary vs secondary care (P = .917). ELF more accurately identified patients with advanced liver fibrosis than indirect marker tests, but ELF and FibroTest had comparable diagnostic accuracies (AUROC of FibroTest, 0.90) (P = .209 for comparison with ELF). Results from the ELF and FibroTest did not differ significantly from those of liver stiffness measurement in intention-to-diagnose analyses (AUROC for transient elastography, 0.90), but did differ in the per-protocol analysis (AUROC for transient elastography, 0.97) (P = .521 and .004 for comparison with ELF). Adding a serum marker to transient elastography analysis did not increase accuracy. For patients in primary care, ELF values below 10.5 and FibroTest values below 0.58 had negative predictive values for advanced liver fibrosis of 98% and 94%, respectively. In a prospective, direct comparison of tests, ELF and FibroTest identified advanced liver fibrosis in alcoholic patients from primary and secondary care with high diagnostic accuracy (AUROC values of 0.90 or higher using biopsy as reference). Advanced fibrosis can be ruled out in primary health care patients based on an ELF value below 10.5 or a FibroTest value below 0.58. Copyright © 2018 AGA Institute. Published by Elsevier Inc. All rights reserved.

  15. A literature review of clinical tests for lumbar instability in low back pain: validity and applicability in clinical practice.

    PubMed

    Ferrari, Silvano; Manni, Tiziana; Bonetti, Francesca; Villafañe, Jorge Hugo; Vanti, Carla

    2015-01-01

    Several clinical tests have been proposed on low back pain (LBP), but their usefulness in detecting lumbar instability is not yet clear. The objective of this literature review was to investigate the clinical validity of the main clinical tests used for the diagnosis of lumbar instability in individuals with LBP and to verify their applicability in everyday clinical practice. We searched studies of the accuracy and/or reliability of Prone Instability Test (PIT), Passive Lumbar Extension Test (PLE), Aberrant Movements Pattern (AMP), Posterior Shear Test (PST), Active Straight Leg Raise Test (ASLR) and Prone and Supine Bridge Tests (PB and SB) in Medline, Embase, Cinahl, PubMed, and Scopus databases. Only the studies in which each test was investigated by at least one study concerning both the accuracy and the reliability were considered eligible. The quality of the studies was evaluated by QUADAS and QAREL scales. Six papers considering 333 LBP patients were included. The PLE was the most accurate and informative clinical test, with high sensitivity (0.84, 95% CI: 0.69 - 0.91) and high specificity (0.90, 95% CI: 0.85 -0.97). The diagnostic accuracy of AMP depends on each singular test. The PIT and the PST demonstrated by fair to moderate sensitivity and specificity [PIT sensitivity = 0.71 (95% CI: 0.51 - 0.83), PIT specificity = 0.57 (95% CI: 039 - 0.78); PST sensitivity = 0.50 (95% CI: 0.41 - 0.76), PST specificity = 0.48 (95% CI: 0.22 - 0.58)]. The PLE showed a good reliability (k = 0.76), but this result comes from a single study. The inter-rater reliability of the PIT ranged by slight (k = 0.10 and 0.04), to good (k = 0.87). The inter-rater reliability of the AMP ranged by slight (k = -0.07) to moderate (k = 0.64), whereas the inter-rater reliability of the PST was fair (k = 0.27). The data from the studies provided information on the methods used and suggest that PLE is the most appropriate tests to detect lumbar instability in specific LBP. However, due to the lack of available papers on other lumbar conditions, these findings should be confirmed with studies on non-specific LBP patients.

  16. Compassion meditation enhances empathic accuracy and related neural activity

    PubMed Central

    Mascaro, Jennifer S.; Rilling, James K.; Tenzin Negi, Lobsang; Raison, Charles L.

    2013-01-01

    The ability to accurately infer others’ mental states from facial expressions is important for optimal social functioning and is fundamentally impaired in social cognitive disorders such as autism. While pharmacologic interventions have shown promise for enhancing empathic accuracy, little is known about the effects of behavioral interventions on empathic accuracy and related brain activity. This study employed a randomized, controlled and longitudinal design to investigate the effect of a secularized analytical compassion meditation program, cognitive-based compassion training (CBCT), on empathic accuracy. Twenty-one healthy participants received functional MRI scans while completing an empathic accuracy task, the Reading the Mind in the Eyes Test (RMET), both prior to and after completion of either CBCT or a health discussion control group. Upon completion of the study interventions, participants randomized to CBCT and were significantly more likely than control subjects to have increased scores on the RMET and increased neural activity in the inferior frontal gyrus (IFG) and dorsomedial prefrontal cortex (dmPFC). Moreover, changes in dmPFC and IFG activity from baseline to the post-intervention assessment were associated with changes in empathic accuracy. These findings suggest that CBCT may hold promise as a behavioral intervention for enhancing empathic accuracy and the neurobiology supporting it. PMID:22956676

  17. A Study on the Effects of Sympathetic Skin Response Parameters in Diagnosis of Fibromyalgia Using Artificial Neural Networks.

    PubMed

    Ozkan, Ozhan; Yildiz, Murat; Arslan, Evren; Yildiz, Sedat; Bilgin, Suleyman; Akkus, Selami; Koyuncuoglu, Hasan R; Koklukaya, Etem

    2016-03-01

    Fibromyalgia syndrome (FMS), usually observed commonly in females over age 30, is a rheumatic disease accompanied by extensive chronic pain. In the diagnosis of the disease non-objective psychological tests and physiological tests and laboratory test results are evaluated and clinical experiences stand out. However, these tests are insufficient in differentiating FMS with similar diseases that demonstrate symptoms of extensive pain. Thus, objective tests that would help the diagnosis are needed. This study analyzes the effect of sympathetic skin response (SSR) parameters on the auxiliary tests used in FMS diagnosis, the laboratory tests and physiological tests. The study was conducted in Suleyman Demirel University, Faculty of Medicine, Physical Medicine and Rehabilitation Clinic in Turkey with 60 patients diagnosed with FMS for the first time and a control group of 30 healthy individuals. In the study all participants underwent laboratory tests (blood tests), certain physiological tests (pulsation, skin temperature, respiration) and SSR measurements. The test data and SSR parameters obtained were classified using artificial neural network (ANN). Finally, in the ANN framework, where only laboratory and physiological test results were used as input, a simulation result of 96.51 % was obtained, which demonstrated diagnostic accuracy. This data, with the addition of SSR parameter values obtained increased to 97.67 %. This result including SSR parameters - meaning a higher diagnostic accuracy - demonstrated that SSR could be a new auxillary diagnostic method that could be used in the diagnosis of FMS.

  18. Lot-to-Lot Variability of Test Strips and Accuracy Assessment of Systems for Self-Monitoring of Blood Glucose according to ISO 15197

    PubMed Central

    Baumstark, Annette; Pleus, Stefan; Schmid, Christina; Link, Manuela; Haug, Cornelia; Freckmann, Guido

    2012-01-01

    Background Accurate and reliable blood glucose (BG) measurements require that different test strip lots of the same BG monitoring system provide comparable measurement results. Only a small number of studies addressing this question have been published. Methods In this study, four test strip lots for each of five different BG systems [Accu-Chek® Aviva (system A), FreeStyle Lite® (system B), GlucoCheck XL (system C), Pura™/mylife™ Pura (system D), and OneTouch® Verio™ Pro (system E)] were evaluated with procedures according to DIN EN ISO 15197:2003. The BG system measurement results were compared with the manufacturer’s measurement procedure (glucose oxidase or hexokinase method). Relative bias according to Bland and Altman and system accuracy according to ISO 15197 were analyzed. A BG system consists of the BG meter itself and the test strips. Results The maximum lot-to-lot difference between any two of the four evaluated test strip lots per BG system was 1.0% for system E, 2.1% for system A, 3.1% for system C, 6.9% for system B, and 13.0% for system D. Only two systems (systems A and B) fulfill the criteria of DIN EN ISO 15197:2003 with each test strip lot. Conclusions Considerable lot-to-lot variability between test strip lots of the same BG system was found. These variations add to other sources of inaccuracy with the specific BG system. Manufacturers should regularly and effectively check the accuracy of their BG meters and test strips even between different test strip lots to minimize risk of false treatment decisions. PMID:23063033

  19. Differentiation of several interstitial lung disease patterns in HRCT images using support vector machine: role of databases on performance

    NASA Astrophysics Data System (ADS)

    Kale, Mandar; Mukhopadhyay, Sudipta; Dash, Jatindra K.; Garg, Mandeep; Khandelwal, Niranjan

    2016-03-01

    Interstitial lung disease (ILD) is complicated group of pulmonary disorders. High Resolution Computed Tomography (HRCT) considered to be best imaging technique for analysis of different pulmonary disorders. HRCT findings can be categorised in several patterns viz. Consolidation, Emphysema, Ground Glass Opacity, Nodular, Normal etc. based on their texture like appearance. Clinician often find it difficult to diagnosis these pattern because of their complex nature. In such scenario computer-aided diagnosis system could help clinician to identify patterns. Several approaches had been proposed for classification of ILD patterns. This includes computation of textural feature and training /testing of classifier such as artificial neural network (ANN), support vector machine (SVM) etc. In this paper, wavelet features are calculated from two different ILD database, publically available MedGIFT ILD database and private ILD database, followed by performance evaluation of ANN and SVM classifiers in terms of average accuracy. It is found that average classification accuracy by SVM is greater than ANN where trained and tested on same database. Investigation continued further to test variation in accuracy of classifier when training and testing is performed with alternate database and training and testing of classifier with database formed by merging samples from same class from two individual databases. The average classification accuracy drops when two independent databases used for training and testing respectively. There is significant improvement in average accuracy when classifiers are trained and tested with merged database. It infers dependency of classification accuracy on training data. It is observed that SVM outperforms ANN when same database is used for training and testing.

  20. Predicting one repetition maximum equations accuracy in paralympic rowers with motor disabilities.

    PubMed

    Schwingel, Paulo A; Porto, Yuri C; Dias, Marcelo C M; Moreira, Mônica M; Zoppi, Cláudio C

    2009-05-01

    Predicting one repetition maximum equations accuracy in paralympic rowers Resistance training intensity is prescribed using percentiles of the maximum strength, defined as the maximum tension generated for a muscle or muscular group. This value is found through the application of the one maximal repetition (1RM) test. One maximal repetition test demands time and still is not appropriate for some populations because of the risk it offers. In recent years, the prediction of maximal strength, through predicting equations, has been used to prevent the inconveniences of the 1RM test. The purpose of this study was to verify the accuracy of 12 1RM predicting equations for disabled rowers. Nine male paralympic rowers (7 one-leg amputated rowers and 2 cerebral paralyzed rowers; age, 30 +/- 7.9 years; height, 175.1 +/- 5.9 cm; weight, 69 +/- 13.6 kg) performed 1RM test for lying T-bar row and flat barbell bench press exercises to determine upper-body strength and leg press exercise to determine lower-body strength. One maximal repetition test was performed, and based on submaximal repetitions loads, several linear and exponential equations models were tested with regard of their accuracy. We did not find statistical differences for lying T-bar row and bench press exercises between measured and predicted 1RM values (p = 0.84 and 0.23 for lying T-bar row and flat barbell bench press, respectively); however, leg press exercise reached a high significant difference between measured and predicted values (p < 0.01). In conclusion, rowers with motor disabilities tolerate 1RM testing procedures, and predicting 1RM equations are accurate for bench press and lying T-bar row, but not for leg press, in this kind of athlete.

  1. EFFECT OF CERVICAL RELINING OF ACRYLIC RESIN COPINGS ON THE ACCURACY OF STONE DIES OBTAINED USING A POLYETHER IMPRESSION MATERIAL

    PubMed Central

    de Sá, André Tomazini Gomes; de Freitas, César Antunes; de Sá, Fátima Cristina; Ursi, Wagner José Silva; Simões, Tânia Christina; de Freitas, Márcia Furtado Antunes

    2008-01-01

    The purpose of this study was to evaluate the accuracy of the respective dies after polyether elastomeric procedure in the presence or absence of cervical contact of the acrylic resin shell with the cervical region, establishing a comparison to dies obtained with stock trays. This study consisted of three groups with 10 specimens each: 1) acrylic copings without cervical contact, (cn); 2) acrylic copings with cervical contact (cc); 3) perforated stock tray, (st). The accuracy of the resulting dies was verified with the aid of a master crown, precisely fit to the master steel die. ANOVA test found statistically significant differences among groups (p<0.001). Tukey's test found that the smallest discrepancy occurred in group cn, followed by cc, while the st group presented the highest difference (cc x cn: p=0.007; st x cn: p<0.001; st x cc: p<0.001). PMID:19089282

  2. Multispectral imaging burn wound tissue classification system: a comparison of test accuracies between several common machine learning algorithms

    NASA Astrophysics Data System (ADS)

    Squiers, John J.; Li, Weizhi; King, Darlene R.; Mo, Weirong; Zhang, Xu; Lu, Yang; Sellke, Eric W.; Fan, Wensheng; DiMaio, J. Michael; Thatcher, Jeffrey E.

    2016-03-01

    The clinical judgment of expert burn surgeons is currently the standard on which diagnostic and therapeutic decisionmaking regarding burn injuries is based. Multispectral imaging (MSI) has the potential to increase the accuracy of burn depth assessment and the intraoperative identification of viable wound bed during surgical debridement of burn injuries. A highly accurate classification model must be developed using machine-learning techniques in order to translate MSI data into clinically-relevant information. An animal burn model was developed to build an MSI training database and to study the burn tissue classification ability of several models trained via common machine-learning algorithms. The algorithms tested, from least to most complex, were: K-nearest neighbors (KNN), decision tree (DT), linear discriminant analysis (LDA), weighted linear discriminant analysis (W-LDA), quadratic discriminant analysis (QDA), ensemble linear discriminant analysis (EN-LDA), ensemble K-nearest neighbors (EN-KNN), and ensemble decision tree (EN-DT). After the ground-truth database of six tissue types (healthy skin, wound bed, blood, hyperemia, partial injury, full injury) was generated by histopathological analysis, we used 10-fold cross validation to compare the algorithms' performances based on their accuracies in classifying data against the ground truth, and each algorithm was tested 100 times. The mean test accuracy of the algorithms were KNN 68.3%, DT 61.5%, LDA 70.5%, W-LDA 68.1%, QDA 68.9%, EN-LDA 56.8%, EN-KNN 49.7%, and EN-DT 36.5%. LDA had the highest test accuracy, reflecting the bias-variance tradeoff over the range of complexities inherent to the algorithms tested. Several algorithms were able to match the current standard in burn tissue classification, the clinical judgment of expert burn surgeons. These results will guide further development of an MSI burn tissue classification system. Given that there are few surgeons and facilities specializing in burn care, this technology may improve the standard of burn care for patients without access to specialized facilities.

  3. Diagnostic accuracy of repetition tasks for the identification of specific language impairment (SLI) in bilingual children: evidence from Russian and Hebrew.

    PubMed

    Armon-Lotem, Sharon; Meir, Natalia

    2016-11-01

    Previous research demonstrates that repetition tasks are valuable tools for diagnosing specific language impairment (SLI) in monolingual children in English and a variety of other languages, with non-word repetition (NWR) and sentence repetition (SRep) yielding high levels of sensitivity and specificity. Yet, only a few studies have addressed the diagnostic accuracy of repetition tasks in bilingual children, and most available research focuses on English-Spanish sequential bilinguals. To evaluate the efficacy of three repetition tasks (forward digit span (FWD), NWR and SRep) in order to distinguish mono- and bilingual children with and without SLI in Russian and Hebrew. A total of 230 mono- and bilingual children aged 5;5-6;8 participated in the study: 144 bilingual Russian-Hebrew-speaking children (27 with SLI); and 52 monolingual Hebrew-speaking children (14 with SLI) and 34 monolingual Russian-speaking children (14 with SLI). Parallel repetition tasks were designed in both Russian and Hebrew. Bilingual children were tested in both languages. The findings confirmed that NWR and SRep are valuable tools in distinguishing monolingual children with and without SLI in Russian and Hebrew, while the results for FWD were mixed. Yet, testing of bilingual children with the same tools using monolingual cut-off points resulted in inadequate diagnostic accuracy. We demonstrate, however, that the use of bilingual cut-off points yielded acceptable levels of diagnostic accuracy. The combination of SRep tasks in L1/Russian and L2/Hebrew yielded the highest overall accuracy (i.e., 94%), but even SRep alone in L2/Hebrew showed excellent levels of sensitivity (i.e., 100%) and specificity (i.e., 89%), reaching 91% of total diagnostic accuracy. The results are very promising for identifying SLI in bilingual children and for showing that testing in the majority language with bilingual cut-off points can provide an accurate classification. © 2016 Royal College of Speech and Language Therapists.

  4. Learning Data Set Influence on Identification Accuracy of Gas Turbine Neural Network Model

    NASA Astrophysics Data System (ADS)

    Kuznetsov, A. V.; Makaryants, G. M.

    2018-01-01

    There are many gas turbine engine identification researches via dynamic neural network models. It should minimize errors between model and real object during identification process. Questions about training data set processing of neural networks are usually missed. This article presents a study about influence of data set type on gas turbine neural network model accuracy. The identification object is thermodynamic model of micro gas turbine engine. The thermodynamic model input signal is the fuel consumption and output signal is the engine rotor rotation frequency. Four types input signals was used for creating training and testing data sets of dynamic neural network models - step, fast, slow and mixed. Four dynamic neural networks were created based on these types of training data sets. Each neural network was tested via four types test data sets. In the result 16 transition processes from four neural networks and four test data sets from analogous solving results of thermodynamic model were compared. The errors comparison was made between all neural network errors in each test data set. In the comparison result it was shown error value ranges of each test data set. It is shown that error values ranges is small therefore the influence of data set types on identification accuracy is low.

  5. Systematic Review of the Performance of Noninvasive Tests in Diagnosing Bladder Outlet Obstruction in Men with Lower Urinary Tract Symptoms.

    PubMed

    Malde, Sachin; Nambiar, Arjun K; Umbach, Roland; Lam, Thomas B; Bach, Thorsten; Bachmann, Alexander; Drake, Marcus J; Gacci, Mauro; Gratzke, Christian; Madersbacher, Stephan; Mamoulakis, Charalampos; Tikkinen, Kari A O; Gravas, Stavros

    2017-03-01

    Several noninvasive tests have been developed for diagnosing bladder outlet obstruction (BOO) in men to avoid the burden and morbidity associated with invasive urodynamics. The diagnostic accuracy of these tests, however, remains uncertain. To systematically review available evidence regarding the diagnostic accuracy of noninvasive tests in diagnosing BOO in men with lower urinary tract symptoms (LUTS) using a pressure-flow study as the reference standard. The EMBASE, MEDLINE, Cochrane Database of Systematic Reviews, Cochrane Central, Google Scholar, and WHO International Clinical Trials Registry Platform Search Portal databases were searched up to May 18, 2016. All studies reporting diagnostic accuracy for noninvasive tests for BOO or detrusor underactivity in men with LUTS compared to pressure-flow studies were included. Two reviewers independently screened all articles, searched the reference lists of retrieved articles, and performed the data extraction. The quality of evidence and risk of bias were assessed using the QUADAS-2 tool. The search yielded 2774 potentially relevant reports. After screening titles and abstracts, 53 reports were retrieved for full-text screening, of which 42 (recruiting a total of 4444 patients) were eligible. Overall, the results were predominantly based on findings from nonrandomised experimental studies and, within the limits of such study designs, the quality of evidence was typically moderate across the literature. Differences in noninvasive test threshold values and variations in the urodynamic definition of BOO between studies limited the comparability of the data. Detrusor wall thickness (median sensitivity 82%, specificity 92%), near-infrared spectroscopy (median sensitivity 85%, specificity 87%), and the penile cuff test (median sensitivity 88%, specificity 75%) were all found to have high sensitivity and specificity in diagnosing BOO. Uroflowmetry with a maximum flow rate of <10ml/s was reported to have lower median sensitivity and specificity of 68% and 70%, respectively. Intravesical prostatic protrusion of >10mm was reported to have similar diagnostic accuracy, with median sensitivity of 68% and specificity of 75%. According to the literature, a number of noninvasive tests have high sensitivity and specificity in diagnosing BOO in men. However, although the majority of studies have a low overall risk of bias, the available evidence is limited by heterogeneity. While several tests have shown promising results regarding noninvasive assessment of BOO, invasive urodynamics remain the gold standard. Urodynamics is an accurate but potentially uncomfortable test for patients in diagnosing bladder problems such as obstruction. We performed a thorough and comprehensive review of the literature to determine if there were less uncomfortable but equally effective alternatives to urodynamics for diagnosing bladder problems. We found that some simple tests appear to be promising, although they are not as accurate. Further research is needed before these tests are routinely used in place of urodynamics. Copyright © 2016 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  6. Diagnosing Sporadic Creutzfeldt-Jakob Disease: Accuracy of CSF 14-3-3 Protein Test of the Spinal Fluid

    MedlinePlus

    ... JAKOB DISEASE: ACCURACY OF THE 14-3-3 PROTEIN TEST OF THE SPINAL FLUID This information sheet ... help you understand how the 14-3-3 protein test helps in diagnosing sporadic Creutzfeldt-Jakob disease ( ...

  7. A feasibility study of Q-sort to determine recall of skin test results and environmental remediation education.

    PubMed

    Townsend, Kristen; Corry, James M; Quigley, Beth Hogan; George, Maureen

    2012-02-01

    Allergic asthma is common in urban minority children and evidence suggests that remediation tailored to the child's allergic profile is the most effective management strategy. The purpose of this pilot study therefore was to examine the caregiver's recall of their child's skin test results and the accuracy of planned remediation ∼4 months after testing. Caregivers were asked to recall their child's skin test results ∼4 months after their skin testing but before any follow-up visit. A Q-sort was then used to determine the knowledge of the recommended remediation. In this Q-sort, caregivers placed 52 cards, each representing one intervention for an indoor allergen, on a response board that prioritized the interventions. At the conclusion of the Q-sort, caregivers received feedback on the accuracy of their recall and prioritization. African American caregivers (5 females; mean age 33.6) of 5 children (4 males; mean age 7.8) were enrolled. No caregiver's recall of skin test results was concordant with the actual results for type or number of allergens. Caregiver's accuracy in prioritizing strategies was 33-100% for cat dander, 40-70% for molds, 70-87% for dust mite allergens, and 100% for the one dog allergic child. Subjects preferred Q-sort to traditional methods of receiving remediation education. Caregivers do not accurately recall skin test results and this may, in part, impede their ability to implement appropriate interventions. A low-literacy game-style approach is a novel strategy to provide complex teaching that warrants further investigation.

  8. Tests for predicting complications of pre-eclampsia: A protocol for systematic reviews

    PubMed Central

    Thangaratinam, Shakila; Coomarasamy, Arri; Sharp, Steve; O'Mahony, Fidelma; O'Brien, Shaughn; Ismail, Khaled MK; Khan, Khalid S

    2008-01-01

    Background Pre-eclampsia is associated with several complications. Early prediction of complications and timely management is needed for clinical care of these patients to avert fetal and maternal mortality and morbidity. There is a need to identify best testing strategies in pre eclampsia to identify the women at increased risk of complications. We aim to determine the accuracy of various tests to predict complications of pre-eclampsia by systematic quantitative reviews. Method We performed extensive search in MEDLINE (1951–2004), EMBASE (1974–2004) and also will also include manual searches of bibliographies of primary and review articles. An initial search has revealed 19500 citations. Two reviewers will independently select studies and extract data on study characteristics, quality and accuracy. Accuracy data will be used to construct 2 × 2 tables. Data synthesis will involve assessment for heterogeneity and appropriately pooling of results to produce summary Receiver Operating Characteristics (ROC) curve and summary likelihood ratios. Discussion This review will generate predictive information and integrate that with therapeutic effectiveness to determine the absolute benefit and harm of available therapy in reducing complications in women with pre-eclampsia. PMID:18694494

  9. Can verbal working memory training improve reading?

    PubMed

    Banales, Erin; Kohnen, Saskia; McArthur, Genevieve

    2015-01-01

    The aim of the current study was to determine whether poor verbal working memory is associated with poor word reading accuracy because the former causes the latter, or the latter causes the former. To this end, we tested whether (a) verbal working memory training improves poor verbal working memory or poor word reading accuracy, and whether (b) reading training improves poor reading accuracy or verbal working memory in a case series of four children with poor word reading accuracy and verbal working memory. Each child completed 8 weeks of verbal working memory training and 8 weeks of reading training. Verbal working memory training improved verbal working memory in two of the four children, but did not improve their reading accuracy. Similarly, reading training improved word reading accuracy in all children, but did not improve their verbal working memory. These results suggest that the causal links between verbal working memory and reading accuracy may not be as direct as has been assumed.

  10. Experimental study of temperature sensor for an ocean-going liquid hydrogen (LH2) carrier

    NASA Astrophysics Data System (ADS)

    Nakano, A.; Shimazaki, T.; Sekiya, M.; Shiozawa, H.; Aoyagi, A.; Ohtsuka, K.; Iwakiri, T.; Mikami, Z.; Sato, M.; Kinoshita, K.; Matsuoka, T.; Takayama, Y.; Yamamoto, K.

    2018-04-01

    The prototype temperature sensors for an ocean-going liquid hydrogen (LH2) carrier were manufactured by way of trial. All of the sensors adopted Platinum 1000 (PT-1000) resistance thermometer elements. Various configurations of preproduction temperature sensors were tested in AIST's LH2 test facility. In the experiments, a PT-1000 resistance thermometer, calibrated at the National Metrology Institute of Japan at AIST, was used as the standard thermometer. The temperatures measured by the preproduction sensors were compared with the temperatures measured by the standard thermometer, and the measurement accuracy of the temperature sensors in LH2 was investigated and discussed. It was confirmed that the measurement accuracies of the preproduction temperature sensors were within ±50 mK, which is the required measurement accuracy for a technical demonstration ocean-going LH2 carrier.

  11. Synthetic Stromgren photometry for F dwarf stars

    NASA Technical Reports Server (NTRS)

    Bell, R. A.

    1988-01-01

    Recent synthetic spectrum and color calculations for cool dwarf star models are tested by comparison with observation. The accuracy of the computed dependence of the thermal colors B-V and b-y on effective temperature is examined, and H-beta indices are presented and compared with observed values. The accuracy of the predictions of the Stromgren uvby system metal-abundance indicator m1 and luminosity indicator c1 are tested. A new calibration of the c1, b-y diagram in terms of absolute magnitudes is given, making use of recent calculations of stellar isochrones. Observations of very metal-poor subdwarfs are used to study the accuracy of the isochrones. The c1, b-y diagram of the subdwarfs is compared with that of the turnoff-region stars in the very metal-poor globular cluster NGC 6397.

  12. Impact of confidence number on accuracy of the SureSight Vision Screener.

    PubMed

    2010-02-01

    To assess the relation between the confidence number provided by the Welch Allyn SureSight Vision Screener and screening accuracy, and to determine whether repeated testing to achieve a higher confidence number improves screening accuracy in pre-school children. Lay and nurse screeners screened 1452 children enrolled in the Vision in Preschoolers (VIP) Phase II Study. All children also underwent a comprehensive eye examination. By using statistical comparison of proportions, we examined sensitivity and specificity for detecting any ocular condition targeted for detection in the VIP study and conditions grouped by severity and by type (amblyopia, strabismus, significant refractive error, and unexplained decreased visual acuity) among children who had confidence numbers < or =4 (retest necessary), 5 (retest if possible), > or =6 (acceptable). Among the 687 (47.3%) children who had repeated testing by either lay or nurse screeners because of a low confidence number (<6) for one or both eyes in the initial testing, the same analyses were also conducted to compare results between the initial reading and repeated test reading with the highest confidence number in the same child. These analyses were based on the failure criteria associated with 90% specificity for detecting any VIP condition in VIP Phase II. A lower confidence number category were associated with higher sensitivity (0.71, 0.65, and 0.59 for < or =4, 5, and > or =6, respectively, p = 0.04) but no statistical difference in specificity (0.85, 0.85, and 0.91, p = 0.07) of detecting any VIP-targeted condition. Children with any VIP-targeted condition were as likely to be detected using the initial confidence number reading as using the higher confidence number reading from repeated testing. A higher confidence number obtained during screening with the SureSight Vision Screener is not associated with better screening accuracy. Repeated testing to reach the manufacturer's recommended minimum value is not helpful in pre-school vision screening.

  13. Laboratory Performance Evaluation Report of SEL 421 Phasor Measurement Unit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Zhenyu; faris, Anthony J.; Martin, Kenneth E.

    2007-12-01

    PNNL and BPA have been in close collaboration on laboratory performance evaluation of phasor measurement units for over ten years. A series of evaluation tests are designed to confirm accuracy and determine measurement performance under a variety of conditions that may be encountered in actual use. Ultimately the testing conducted should provide parameters that can be used to adjust all measurements to a standardized basis. These tests are performed with a standard relay test set using recorded files of precisely generated test signals. The test set provides test signals at a level and in a format suitable for input tomore » a PMU that accurately reproduces the signals in both signal amplitude and timing. Test set outputs are checked to confirm the accuracy of the output signal. The recorded signals include both current and voltage waveforms and a digital timing track used to relate the PMU measured value with the test signal. Test signals include steady-state waveforms to test amplitude, phase, and frequency accuracy, modulated signals to determine measurement and rejection bands, and step tests to determine timing and response accuracy. Additional tests are included as necessary to fully describe the PMU operation. Testing is done with a BPA phasor data concentrator (PDC) which provides communication support and monitors data input for dropouts and data errors.« less

  14. Model Performance of Water-Current Meters

    USGS Publications Warehouse

    Fulford, J.M.; ,

    2002-01-01

    The measurement of discharge in natural streams requires hydrographers to use accurate water-current meters that have consistent performance among meters of the same model. This paper presents the results of an investigation into the performance of four models of current meters - Price type-AA, Price pygmy, Marsh McBirney 2000 and Swoffer 2100. Tests for consistency and accuracy for six meters of each model are summarized. Variation of meter performance within a model is used as an indicator of consistency, and percent velocity error that is computed from a measured reference velocity is used as an indicator of meter accuracy. Velocities measured by each meter are also compared to the manufacturer's published or advertised accuracy limits. For the meters tested, the Price models werer found to be more accurate and consistent over the range of test velocities compared to the other models. The Marsh McBirney model usually measured within its accuracy specification. The Swoffer meters did not meet the stringent Swoffer accuracy limits for all the velocities tested.

  15. Accuracy statistics in predicting Independent Activities of Daily Living (IADL) capacity with comprehensive and brief neuropsychological test batteries.

    PubMed

    Karzmark, Peter; Deutsch, Gayle K

    2018-01-01

    This investigation was designed to determine the predictive accuracy of a comprehensive neuropsychological and brief neuropsychological test battery with regard to the capacity to perform instrumental activities of daily living (IADLs). Accuracy statistics that included measures of sensitivity, specificity, positive and negative predicted power and positive likelihood ratio were calculated for both types of batteries. The sample was drawn from a general neurological group of adults (n = 117) that included a number of older participants (age >55; n = 38). Standardized neuropsychological assessments were administered to all participants and were comprised of the Halstead Reitan Battery and portions of the Wechsler Adult Intelligence Scale-III. A comprehensive test battery yielded a moderate increase over base-rate in predictive accuracy that generalized to older individuals. There was only limited support for using a brief battery, for although sensitivity was high, specificity was low. We found that a comprehensive neuropsychological test battery provided good classification accuracy for predicting IADL capacity.

  16. Genomic selection models double the accuracy of predicted breeding values for bacterial cold water disease resistance compared to a traditional pedigree-based model in rainbow trout aquaculture.

    PubMed

    Vallejo, Roger L; Leeds, Timothy D; Gao, Guangtu; Parsons, James E; Martin, Kyle E; Evenhuis, Jason P; Fragomeni, Breno O; Wiens, Gregory D; Palti, Yniv

    2017-02-01

    Previously, we have shown that bacterial cold water disease (BCWD) resistance in rainbow trout can be improved using traditional family-based selection, but progress has been limited to exploiting only between-family genetic variation. Genomic selection (GS) is a new alternative that enables exploitation of within-family genetic variation. We compared three GS models [single-step genomic best linear unbiased prediction (ssGBLUP), weighted ssGBLUP (wssGBLUP), and BayesB] to predict genomic-enabled breeding values (GEBV) for BCWD resistance in a commercial rainbow trout population, and compared the accuracy of GEBV to traditional estimates of breeding values (EBV) from a pedigree-based BLUP (P-BLUP) model. We also assessed the impact of sampling design on the accuracy of GEBV predictions. For these comparisons, we used BCWD survival phenotypes recorded on 7893 fish from 102 families, of which 1473 fish from 50 families had genotypes [57 K single nucleotide polymorphism (SNP) array]. Naïve siblings of the training fish (n = 930 testing fish) were genotyped to predict their GEBV and mated to produce 138 progeny testing families. In the following generation, 9968 progeny were phenotyped to empirically assess the accuracy of GEBV predictions made on their non-phenotyped parents. The accuracy of GEBV from all tested GS models were substantially higher than the P-BLUP model EBV. The highest increase in accuracy relative to the P-BLUP model was achieved with BayesB (97.2 to 108.8%), followed by wssGBLUP at iteration 2 (94.4 to 97.1%) and 3 (88.9 to 91.2%) and ssGBLUP (83.3 to 85.3%). Reducing the training sample size to n = ~1000 had no negative impact on the accuracy (0.67 to 0.72), but with n = ~500 the accuracy dropped to 0.53 to 0.61 if the training and testing fish were full-sibs, and even substantially lower, to 0.22 to 0.25, when they were not full-sibs. Using progeny performance data, we showed that the accuracy of genomic predictions is substantially higher than estimates obtained from the traditional pedigree-based BLUP model for BCWD resistance. Overall, we found that using a much smaller training sample size compared to similar studies in livestock, GS can substantially improve the selection accuracy and genetic gains for this trait in a commercial rainbow trout breeding population.

  17. Performance analysis of the OneTouch UltraVue blood glucose monitoring system.

    PubMed

    Chang, Anna; Orth, Alice; Le, Bryan; Menchavez, Perla; Miller, Lupe

    2009-09-01

    OneTouch UltraVue is a new meter for self-monitoring of blood glucose that includes a color display, used-strip ejector, and no-button interface. The system uses an electrochemical biosensor technology based on glucose oxidase chemistry to detect glucose concentrations from 20 to 600 mg/dl (1.1 to 33.3 mmol/liter). Accuracy and reproducibility were evaluated over a wide range of glucose concentrations according to standard criteria. Clinical accuracy was assessed by health care providers (HCPs) in two studies and by diabetes patients in the second study. Reference glucose levels were determined by a YSI 2300 analyzer. Same-day reproducibility and day-to-day reproducibility were also evaluated. In the accuracy studies, 99.7% and 98.7% of tests by HCPs and 97.0% of tests by patients were within +/-15 mg/dl (+/-0.8 mmol/liter) of the YSI reference for blood glucose <75 mg/dl (<4.2 mmol/liter), and within +/-20% for blood glucose > or =75 mg/dl (> or =4.2 mmol/liter), respectively. Consensus error grid analysis showed that 99.7% and 95.3% of tests by HCPs and 97.0% of tests by patients fell within zone A (i.e., has no effect on clinical action); all other results were in zone B (i.e., altered clinical action, little or no effect on clinical outcome). In the reproducibility studies, the standard deviation was <1.5 mg/dl (<0.1 mmol/liter) for glucose concentrations <100 mg/dl (<5.6 mmol/liter), and the coefficient of variation was <2% for concentrations > or = 100 mg/dl (> or =5.6 mmol/liter). OneTouch UltraVue meets standard acceptability criteria for accuracy and reproducibility across a wide range of glucose concentrations. Its simple interface and lack of contact with used strips make it a viable option for older patients and their caregivers. 2009 Diabetes Technology Society.

  18. Performance Analysis of the OneTouch® UltraVue™ Blood Glucose Monitoring System

    PubMed Central

    Chang, Anna; Orth, Alice; Le, Bryan; Menchavez, Perla; Miller, Lupe

    2009-01-01

    Background OneTouch® UltraVue™ is a new meter for self-monitoring of blood glucose that includes a color display, used-strip ejector, and no-button interface. The system uses an electrochemical biosensor technology based on glucose oxidase chemistry to detect glucose concentrations from 20 to 600 mg/dl (1.1 to 33.3 mmol/liter). Methods Accuracy and reproducibility were evaluated over a wide range of glucose concentrations according to standard criteria. Clinical accu-racy was assessed by health care providers (HCPs) in two studies and by diabetes patients in the second study. Reference glucose lev-els were determined by a YSI 2300 analyzer. Same-day reproducibility and day-to-day reproducibility were also evaluated. Results In the accuracy studies, 99.7% and 98.7% of tests by HCPs and 97.0% of tests by patients were within ±15 mg/dl (±0.8 mmol/liter) of the YSI reference for blood glucose <75 mg/dl (<4.2 mmol/liter), and within ±20% for blood glucose ≥75 mg/dl (≥4.2 mmol/liter), respectively. Consensus error grid analysis showed that 99.7% and 95.3% of tests by HCPs and 97.0% of tests by patients fell within zone A (i.e., has no effect on clinical action); all other results were in zone B (i.e., altered clinical action, little or no effect on clini-cal outcome). In the reproducibility studies, the standard deviation was <1.5 mg/dl (<0.1 mmol/liter) for glucose concentra-tions <100 mg/dl (<5.6 mmol/liter), and the coefficient of variation was <2% for concentrations ≥100 mg/dl (≥5.6 mmol/liter). Conclusions OneTouch UltraVue meets standard acceptability criteria for accuracy and reproducibility across a wide range of glucose concentra-tions. Its simple interface and lack of contact with used strips make it a viable option for older patients and their caregivers. PMID:20144431

  19. Exploring Proficiency-Based vs. Performance-Based Items with Elicited Imitation Assessment

    ERIC Educational Resources Information Center

    Cox, Troy L.; Bown, Jennifer; Burdis, Jacob

    2015-01-01

    This study investigates the effect of proficiency- vs. performance-based elicited imitation (EI) assessment. EI requires test-takers to repeat sentences in the target language. The accuracy at which test-takers are able to repeat sentences highly correlates with test-takers' language proficiency. However, in EI, the factors that render an item…

  20. An integrated use of topography with RSI in gully mapping, Shandong Peninsula, China.

    PubMed

    He, Fuhong; Wang, Tao; Gu, Lijuan; Li, Tao; Jiang, Weiguo; Shao, Hongbo

    2014-01-01

    Taking the Quickbird optical satellite imagery of the small watershed of Beiyanzigou valley of Qixia city, Shandong province, as the study data, we proposed a new method by using a fused image of topography with remote sensing imagery (RSI) to achieve a high precision interpretation of gully edge lines. The technique first transformed remote sensing imagery into HSV color space from RGB color space. Then the slope threshold values of gully edge line and gully thalweg were gained through field survey and the slope data were segmented using thresholding, respectively. Based on the fused image in combination with gully thalweg thresholding vectors, the gully thalweg thresholding vectors were amended. Lastly, the gully edge line might be interpreted based on the amended gully thalweg vectors, fused image, gully edge line thresholding vectors, and slope data. A testing region was selected in the study area to assess the accuracy. Then accuracy assessment of the gully information interpreted by both interpreting remote sensing imagery only and the fused image was performed using the deviation, kappa coefficient, and overall accuracy of error matrix. Compared with interpreting remote sensing imagery only, the overall accuracy and kappa coefficient are increased by 24.080% and 264.364%, respectively. The average deviations of gully head and gully edge line are reduced by 60.448% and 67.406%, respectively. The test results show the thematic and the positional accuracy of gully interpreted by new method are significantly higher. Finally, the error sources for interpretation accuracy by the two methods were analyzed.

  1. An Integrated Use of Topography with RSI in Gully Mapping, Shandong Peninsula, China

    PubMed Central

    He, Fuhong; Wang, Tao; Gu, Lijuan; Li, Tao; Jiang, Weiguo; Shao, Hongbo

    2014-01-01

    Taking the Quickbird optical satellite imagery of the small watershed of Beiyanzigou valley of Qixia city, Shandong province, as the study data, we proposed a new method by using a fused image of topography with remote sensing imagery (RSI) to achieve a high precision interpretation of gully edge lines. The technique first transformed remote sensing imagery into HSV color space from RGB color space. Then the slope threshold values of gully edge line and gully thalweg were gained through field survey and the slope data were segmented using thresholding, respectively. Based on the fused image in combination with gully thalweg thresholding vectors, the gully thalweg thresholding vectors were amended. Lastly, the gully edge line might be interpreted based on the amended gully thalweg vectors, fused image, gully edge line thresholding vectors, and slope data. A testing region was selected in the study area to assess the accuracy. Then accuracy assessment of the gully information interpreted by both interpreting remote sensing imagery only and the fused image was performed using the deviation, kappa coefficient, and overall accuracy of error matrix. Compared with interpreting remote sensing imagery only, the overall accuracy and kappa coefficient are increased by 24.080% and 264.364%, respectively. The average deviations of gully head and gully edge line are reduced by 60.448% and 67.406%, respectively. The test results show the thematic and the positional accuracy of gully interpreted by new method are significantly higher. Finally, the error sources for interpretation accuracy by the two methods were analyzed. PMID:25302333

  2. Bridging naturalistic and laboratory assessment of memory: the Baycrest mask fit test.

    PubMed

    Armson, Michael J; Abdi, Hervé; Levine, Brian

    2017-09-01

    Autobiographical memory tests provide a naturalistic counterpoint to the artificiality of laboratory research methods, yet autobiographical events are uncontrolled and, in most cases, unverifiable. In this study, we capitalised on a scripted, complex naturalistic event - the mask fit test (MFT), a standardised procedure required of hospital employees - to bridge the gap between naturalistic and laboratory memory assessment. We created a test of recognition memory for the MFT and administered it to 135 hospital employees who had undertaken the MFT at various points over the past five years. Multivariate analysis revealed two dimensions defined by accuracy and response bias. Accuracy scores showed the expected relationship to encoding-test delay, supporting the validity of this measure. Relative to younger adults, older adults' memory for this naturalistic event was better than would be predicted from the cognitive ageing literature, a result consistent with the notion that older adults' memory performance is enhanced when stimuli are naturalistic and personally relevant. These results demonstrate that testing recognition memory for a scripted event is a viable method of studying autobiographical memory.

  3. Bivariate random-effects meta-analysis models for diagnostic test accuracy studies using arcsine-based transformations.

    PubMed

    Negeri, Zelalem F; Shaikh, Mateen; Beyene, Joseph

    2018-05-11

    Diagnostic or screening tests are widely used in medical fields to classify patients according to their disease status. Several statistical models for meta-analysis of diagnostic test accuracy studies have been developed to synthesize test sensitivity and specificity of a diagnostic test of interest. Because of the correlation between test sensitivity and specificity, modeling the two measures using a bivariate model is recommended. In this paper, we extend the current standard bivariate linear mixed model (LMM) by proposing two variance-stabilizing transformations: the arcsine square root and the Freeman-Tukey double arcsine transformation. We compared the performance of the proposed methods with the standard method through simulations using several performance measures. The simulation results showed that our proposed methods performed better than the standard LMM in terms of bias, root mean square error, and coverage probability in most of the scenarios, even when data were generated assuming the standard LMM. We also illustrated the methods using two real data sets. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Indicators of Late Emerging Reading-Accuracy Difficulties in Australian Schools

    ERIC Educational Resources Information Center

    Galletly, Susan A.; Knight, Bruce Allen; Dekkers, John; Galletly, Tracey A.

    2009-01-01

    Late-emerging reading-accuracy difficulties are those found present in older students not showing reading-accuracy difficulties when tested in earlier years (Leach, Scarborough and Rescorla, 2003). This paper discusses the constructs of reading-accuracy and late-emerging reading-accuracy difficulties. It then discusses data from a cross-sectional…

  5. Recollection can be Weak and Familiarity can be Strong

    PubMed Central

    Ingram, Katherine M.; Mickes, Laura; Wixted, John T.

    2012-01-01

    The Remember/Know procedure is widely used to investigate recollection and familiarity in recognition memory, but almost all of the results obtained using that procedure can be readily accommodated by a unidimensional model based on signal-detection theory. The unidimensional model holds that Remember judgments reflect strong memories (associated with high confidence, high accuracy, and fast reaction times), whereas Know judgments reflect weaker memories (associated with lower confidence, lower accuracy, and slower reaction times). Although this is invariably true on average, a new two-dimensional account (the Continuous Dual-Process model) suggests that Remember judgments made with low confidence should be associated with lower old/new accuracy, but higher source accuracy, than Know judgments made with high confidence. We tested this prediction – and found evidence to support it – using a modified Remember/Know procedure in which participants were first asked to indicate a degree of recollection-based or familiarity-based confidence for each word presented on a recognition test and were then asked to recollect the color (red or blue) and screen location (top or bottom) associated with the word at study. For familiarity-based decisions, old/new accuracy increased with old/new confidence, but source accuracy did not (suggesting that stronger old/new memory was supported by higher degrees of familiarity). For recollection-based decisions, both old/new accuracy and source accuracy increased with old/new confidence (suggesting that stronger old/new memory was supported by higher degrees of recollection). These findings suggest that recollection and familiarity are continuous processes and that participants can indicate which process mainly contributed to their recognition decisions. PMID:21967320

  6. Testing of the McMath-Pierce 0.8-Meter East Auxiliary Telescope's Acquisition and Slewing Accuracy

    NASA Astrophysics Data System (ADS)

    Harshaw, Richard; Ray, Jimmy; Prause, Lori; Douglass, David; Branston, Detrick; Genet, Russell M.

    2015-09-01

    Following mediocre results with pointing tests of the McMath-Pierce 0.8-meter East Auxiliary Telescope in April 2014, a team of astronomers/engineers met again in May 2014 to test other pointing models and assess the telescope's ability to point with enough accuracy to permit the efficient use of speckle interferometry. Results show that accurate collimation is a pre-requisite for such accuracy. Once attained, the telescope performs extremely well.

  7. Empathic Accuracy in Adolescents with Autism Spectrum Disorders and Adolescents with Attention-Deficit/Hyperactivity Disorder

    ERIC Educational Resources Information Center

    Demurie, Ellen; De Corel, Maaike; Roeyers, Herbert

    2011-01-01

    In research on theory of mind (ToM) in individuals with an autism spectrum disorder (ASD) mainly static mind-reading tasks were used. In this study both a static (Eyes Test) and a more naturalistic (empathic accuracy task) ToM measure were used to investigate the perspective taking abilities of adolescents with ASD (n = 13), adolescents with…

  8. The Effect of All-Capital vs. Regular Mixed Print, as Presented on a Computer Screen, on Reading Rate and Accuracy.

    ERIC Educational Resources Information Center

    Henney, Maribeth

    Two related studies were conducted to determine whether students read all-capital text and mixed text displayed on a computer screen with the same speed and accuracy. Seventy-seven college students read M. A. Tinker's "Basic Reading Rate Test" displayed on a PLATO computer screen. One treatment consisted of paragraphs in all-capital type…

  9. Blood glucose monitoring skills in children with Type I diabetes.

    PubMed

    Perwien, A R; Johnson, S B; Dymtrow, D; Silverstein, J

    2000-06-01

    While blood glucose monitoring has become increasingly important in diabetes care, studies have yet to address the accuracy of youngsters' performance of blood glucose testing with current reflectance meters. The present study examined testing skills and predictors of accurate testing skills in a sample of 7-14-year-old children attending a summer camp for youth with diabetes (n=266). A 15-item behavior observational skill test was used to assess accuracy of blood glucose monitoring skills with reflectance meters. Accurate performance of individual skills ranged between 14.6% and 99.6% for the sample. However, a number of children made critical errors (errors that were likely to lead to inaccurate blood glucose testing results). When duration of diabetes and metabolic control were controlled, female gender, older age, experience with a particular meter, and absence of hypoglycemia at the time of testing were positively associated with accurate skill performance. Findings suggest that younger children, children using a new blood glucose testing meter, and children suspected of having hypoglycemia should be supervised and observed when testing. Although all young children should be supervised when blood glucose testing, boys may need closer supervision until an older age than girls. This study underscores the need for health care providers to periodically observe children's blood glucose monitoring techniques to assure accurate testing habits and to correct problematic testing behaviors.

  10. Predictive Accuracy of Exercise Stress Testing the Healthy Adult.

    ERIC Educational Resources Information Center

    Lamont, Linda S.

    1981-01-01

    Exercise stress testing provides information on the aerobic capacity, heart rate, and blood pressure responses to graded exercises of a healthy adult. The reliability of exercise tests as a diagnostic procedure is discussed in relation to sensitivity and specificity and predictive accuracy. (JN)

  11. Optic nerve head and fibre layer imaging for diagnosing glaucoma.

    PubMed

    Michelessi, Manuele; Lucenteforte, Ersilia; Oddone, Francesco; Brazzelli, Miriam; Parravano, Mariacristina; Franchi, Sara; Ng, Sueko M; Virgili, Gianni

    2015-11-30

    The diagnosis of glaucoma is traditionally based on the finding of optic nerve head (ONH) damage assessed subjectively by ophthalmoscopy or photography or by corresponding damage to the visual field assessed by automated perimetry, or both. Diagnostic assessments are usually required when ophthalmologists or primary eye care professionals find elevated intraocular pressure (IOP) or a suspect appearance of the ONH. Imaging tests such as confocal scanning laser ophthalmoscopy (HRT), optical coherence tomography (OCT) and scanning laser polarimetry (SLP, as used by the GDx instrument), provide an objective measure of the structural changes of retinal nerve fibre layer (RNFL) thickness and ONH parameters occurring in glaucoma. To determine the diagnostic accuracy of HRT, OCT and GDx for diagnosing manifest glaucoma by detecting ONH and RNFL damage. We searched several databases for this review. The most recent searches were on 19 February 2015. We included prospective and retrospective cohort studies and case-control studies that evaluated the accuracy of OCT, HRT or the GDx for diagnosing glaucoma. We excluded population-based screening studies, since we planned to consider studies on self-referred people or participants in whom a risk factor for glaucoma had already been identified in primary care, such as elevated IOP or a family history of glaucoma. We only considered recent commercial versions of the tests: spectral domain OCT, HRT III and GDx VCC or ECC. We adopted standard Cochrane methods. We fitted a hierarchical summary ROC (HSROC) model using the METADAS macro in SAS software. After studies were selected, we decided to use 2 x 2 data at 0.95 specificity or closer in meta-analyses, since this was the most commonly-reported level. We included 106 studies in this review, which analysed 16,260 eyes (8353 cases, 7907 controls) in total. Forty studies (5574 participants) assessed GDx, 18 studies (3550 participants) HRT, and 63 (9390 participants) OCT, with 12 of these studies comparing two or three tests. Regarding study quality, a case-control design in 103 studies raised concerns as it can overestimate accuracy and reduce the applicability of the results to daily practice. Twenty-four studies were sponsored by the manufacturer, and in 15 the potential conflict of interest was unclear.Comparisons made within each test were more reliable than those between tests, as they were mostly based on direct comparisons within each study.The Nerve Fibre Indicator yielded the highest accuracy (estimate, 95% confidence interval (CI)) among GDx parameters (sensitivity: 0.67, 0.55 to 0.77; specificity: 0.94, 0.92 to 0.95). For HRT measures, the Vertical Cup/Disc (C/D) ratio (sensitivity: 0.72, 0.60 to 0.68; specificity: 0.94, 0.92 to 0.95) was no different from other parameters. With OCT, the accuracy of average RNFL retinal thickness was similar to the inferior sector (0.72, 0.65 to 0.77; specificity: 0.93, 0.92 to 0.95) and, in different studies, to the vertical C/D ratio.Comparing the parameters with the highest diagnostic odds ratio (DOR) for each device in a single HSROC model, the performance of GDx, HRT and OCT was remarkably similar. At a sensitivity of 0.70 and a high specificity close to 0.95 as in most of these studies, in 1000 people referred by primary eye care, of whom 200 have manifest glaucoma, such as in those who have already undergone some functional or anatomic testing by optometrists, the best measures of GDx, HRT and OCT would miss about 60 cases out of the 200 patients with glaucoma, and would incorrectly refer 50 out of 800 patients without glaucoma. If prevalence were 5%, e.g. such as in people referred only because of family history of glaucoma, the corresponding figures would be 15 patients missed out of 50 with manifest glaucoma, avoiding referral of about 890 out of 950 non-glaucomatous people.Heterogeneity investigations found that sensitivity estimate was higher for studies with more severe glaucoma, expressed as worse average mean deviation (MD): 0.79 (0.74 to 0.83) for MD < -6 db versus 0.64 (0.60 to 0.69) for MD ≥ -6 db, at a similar summary specificity (0.93, 95% CI 0.92 to 0.94 and, respectively, 0.94; 95% CI 0.93 to 0.95; P < 0.0001 for the difference in relative DOR). The accuracy of imaging tests for detecting manifest glaucoma was variable across studies, but overall similar for different devices. Accuracy may have been overestimated due to the case-control design, which is a serious limitation of the current evidence base.We recommend that further diagnostic accuracy studies are carried out on patients selected consecutively at a defined step of the clinical pathway, providing a description of risk factors leading to referral and bearing in mind the consequences of false positives and false negatives in the setting in which the diagnostic question is made. Future research should report accuracy for each threshold of these continuous measures, or publish raw data.

  12. Data mining methods in the prediction of Dementia: A real-data comparison of the accuracy, sensitivity and specificity of linear discriminant analysis, logistic regression, neural networks, support vector machines, classification trees and random forests

    PubMed Central

    2011-01-01

    Background Dementia and cognitive impairment associated with aging are a major medical and social concern. Neuropsychological testing is a key element in the diagnostic procedures of Mild Cognitive Impairment (MCI), but has presently a limited value in the prediction of progression to dementia. We advance the hypothesis that newer statistical classification methods derived from data mining and machine learning methods like Neural Networks, Support Vector Machines and Random Forests can improve accuracy, sensitivity and specificity of predictions obtained from neuropsychological testing. Seven non parametric classifiers derived from data mining methods (Multilayer Perceptrons Neural Networks, Radial Basis Function Neural Networks, Support Vector Machines, CART, CHAID and QUEST Classification Trees and Random Forests) were compared to three traditional classifiers (Linear Discriminant Analysis, Quadratic Discriminant Analysis and Logistic Regression) in terms of overall classification accuracy, specificity, sensitivity, Area under the ROC curve and Press'Q. Model predictors were 10 neuropsychological tests currently used in the diagnosis of dementia. Statistical distributions of classification parameters obtained from a 5-fold cross-validation were compared using the Friedman's nonparametric test. Results Press' Q test showed that all classifiers performed better than chance alone (p < 0.05). Support Vector Machines showed the larger overall classification accuracy (Median (Me) = 0.76) an area under the ROC (Me = 0.90). However this method showed high specificity (Me = 1.0) but low sensitivity (Me = 0.3). Random Forest ranked second in overall accuracy (Me = 0.73) with high area under the ROC (Me = 0.73) specificity (Me = 0.73) and sensitivity (Me = 0.64). Linear Discriminant Analysis also showed acceptable overall accuracy (Me = 0.66), with acceptable area under the ROC (Me = 0.72) specificity (Me = 0.66) and sensitivity (Me = 0.64). The remaining classifiers showed overall classification accuracy above a median value of 0.63, but for most sensitivity was around or even lower than a median value of 0.5. Conclusions When taking into account sensitivity, specificity and overall classification accuracy Random Forests and Linear Discriminant analysis rank first among all the classifiers tested in prediction of dementia using several neuropsychological tests. These methods may be used to improve accuracy, sensitivity and specificity of Dementia predictions from neuropsychological testing. PMID:21849043

  13. Accuracy Analysis of a Wireless Indoor Positioning System Using Geodetic Methods

    NASA Astrophysics Data System (ADS)

    Wagner, Przemysław; Woźniak, Marek; Odziemczyk, Waldemar; Pakuła, Dariusz

    2017-12-01

    Ubisense RTLS is one of the Indoor positioning systems using an Ultra Wide Band. AOA and TDOA methods are used as a principle of positioning. The accuracy of positioning depends primarily on the accuracy of determined angles and distance differences. The paper presents the results of accuracy research which includes a theoretical accuracy prediction and a practical test. Theoretical accuracy was calculated for two variants of system components geometry, assuming the parameters declared by the system manufacturer. Total station measurements were taken as a reference during the practical test. The results of the analysis are presented in a graphical form. A sample implementation (MagMaster) developed by Globema is presented in the final part of the paper.

  14. Swing arm profilometer: high accuracy testing for large reaction-bonded silicon carbide optics with a capacitive probe

    NASA Astrophysics Data System (ADS)

    Xiong, Ling; Luo, Xiao; Hu, Hai-xiang; Zhang, Zhi-yu; Zhang, Feng; Zheng, Li-gong; Zhang, Xue-jun

    2017-08-01

    A feasible way to improve the manufacturing efficiency of large reaction-bonded silicon carbide optics is to increase the processing accuracy in the ground stage before polishing, which requires high accuracy metrology. A swing arm profilometer (SAP) has been used to measure large optics during the ground stage. A method has been developed for improving the measurement accuracy of SAP using a capacitive probe and implementing calibrations. The experimental result compared with the interferometer test shows the accuracy of 0.068 μm in root-mean-square (RMS) and maps in 37 low-order Zernike terms show accuracy of 0.048 μm RMS, which shows a powerful capability to provide a major input in high-precision grinding.

  15. Magnetic resonance defecography versus videodefecography in the study of obstructed defecation syndrome: Is videodefecography still the test of choice after 50 years?

    PubMed

    Martín-Martín, G P; García-Armengol, J; Roig-Vila, J V; Espí-Macías, A; Martínez-Sanjuán, V; Mínguez-Pérez, M; Lorenzo-Liñán, M Á; Mulas-Fernández, C; González-Argenté, F X

    2017-10-01

    The aim of the present study was to evaluate the diagnostic accuracy of magnetic resonance (MR) defecography and compare it with videodefecography in the evaluation of obstructed defecation syndrome. This was a prospective cohort test accuracy study conducted at one major tertiary referral center on patients with a diagnosis of obstructed defecation syndrome who were referred to the colorectal surgery clinic in a consecutive series from 2009 to 2012. All patients underwent a clinical examination, videodefecography, and MR defecography in the supine position. We analyzed diagnostic accuracy for MR defecography and performed an agreement analysis using Cohen's kappa index (κ) for each diagnostic imaging examination performed with videodefecography and MR defecography. We included 40 patients with Rome III diagnostic criteria of obstructed defecation syndrome. The degree of agreement between the two tests was as follows: almost perfect for anismus (κ = 0.88) and rectal prolapse (κ = 0.83), substantial for enterocele (κ = 0.80) and rectocele grade III (κ = 0.65), moderate for intussusception (κ = 0.50) and rectocele grade II (κ = 0.49), and slight for rectocele grade I (κ = 0.30) and excessive perineal descent (κ = 0.22). Eighteen cystoceles and 11 colpoceles were diagnosed only by MR defecography. Most patients (54%) stated that videodefecography was the more uncomfortable test. MR defecography could become the imaging test of choice for evaluating obstructed defecation syndrome.

  16. A meta-analysis of the diagnostic test accuracy of MRA and MRI for the detection of glenoid labral injury.

    PubMed

    Smith, Toby O; Drew, Benjamin T; Toms, Andoni P

    2012-07-01

    Magnetic resonance imaging (MRI) and magnetic resonance arthrography (MRA) have gained increasing favour in the assessment of patients with suspected glenoid labral injuries. The purpose of this study was to determine the diagnostic accuracy of MRI or MRA in the detection of gleniod labral lesions. A systematic review was undertaken of the electronic databases Cochrane Central Register of Controlled Trials, MEDLINE, EMBASE, AMED and CINAHL, in addition to a search of unpublished literature databases. All studies which compared the ability of MRI or MRA (index test) to assess gleniod labral tears or lesions, when verified with a surgical procedure (arthroscopy or open surgery-reference test) were included. Data extraction and methodological appraisal using the QUADAS tool were both conducted by two reviewers independently. Data were analysed through a summary receiver operator characteristic curve and pooled sensitivity and specificity analysis were calculated with 95% confidence intervals. Sixty studies including 4,667 shoulders from 4,574 patients were reviewed. There appeared slightly greater diagnostic test accuracy for MRA over MRI for the detection of overall gleniod labral lesions (MRA-sensitivity 88%, specificity 93% vs. MRI sensitivity 76% vs. specificity 87%). Methodologically, studies recruited and identified their samples appropriately and clearly defined the radiological procedures. In general, it was not clearly defined why patients were lost during the study, and studies were poor at recording whether the same clinical data were available to the radiologist interpreting the MRI or MRA as would be available in clinical practice. Most studies did not state whether the surgeon interpreting the arthroscopic procedure was blinded to the results of the MR or MRA imaging. Based on the available literature, overall MRA appeared marginally superior to MRI for the detection of glenohumeral labral lesions. Level 2a.

  17. Comparative testing of pulse oximeter probes.

    PubMed

    van Oostrom, Johannes H; Melker, Richard J

    2004-05-01

    The testing of pulse oximeter probes is generally limited to the integrity of the electrical circuit and does not include the optical properties of the probes. Few pulse oximeter testers evaluate the accuracy of both the monitor and the probe. We designed a study to compare the accuracy of nonproprietary probes (OSS Medical) designed for use with Nellcor, Datex-Ohmeda, and Criticare pulse oximeter monitors with that of their corresponding proprietary probes by using a commercial off-the-shelf pulse oximeter tester (Index). The Index pulse oximeter tester does include testing of the optical properties of the pulse oximeter probes. The pulse oximeter tester was given a controlled input that simulated acute apnea. Desaturation curves were automatically recorded from the pulse oximeter monitors with a data-collection computer. Comparisons between equivalent proprietary and nonproprietary probes were performed. Data were analyzed by using univariate and multivariate general linear model analysis. Five OSS Medical probe models were statistically better than the equivalent proprietary probes. The remainder of the probes were statistically similar. Comparative and simulation studies can have significant advantages over human studies because they are cost-effective, evaluate equipment in a clinically relevant scenario, and pose no risk to patients, but they are limited by the realism of the simulation. We studied the performance of pulse oximeter probes in a simulated environment. Our results show significant differences between some probes that affect the accuracy of measurement.

  18. Accuracy of prospective memory tests in mild Alzheimer's disease.

    PubMed

    Martins, Sergilaine Pereira; Damasceno, Benito Pereira

    2012-01-01

    To verify the accuracy of prospective memory (ProM) tests in Alzheimer's disease (AD). Twenty mild AD patients (CDR 1), and 20 controls underwent Digit Span (DS), Trail Making (TM) A and B, visual perception, Rey Auditory-Verbal Learning tests, and Cornell Scale for Depression. AD diagnosis was based on DSM-IV and NINCDS-ADRDA criteria. ProM was assessed with the appointment and belonging subtests of Rivermead Behavioral Memory Test (RBMT); and with two new tests (the clock and animal tests). AD patients had a worse performance than controls on the majority of tests, except DS forward and TM-A. There was no correlation between RBMT and the new ProM tests. As for accuracy, the only significant difference concerned the higher sensitivity of our animal test versus the RBMT belonging test. The clock and the animal tests showed similar specificity, but higher sensitivity than the RBMT subtests.

  19. Determining predictability and accuracy of thermal and electrical dental pulp tests: An in vivo study.

    PubMed

    Salgar, Avinash Ramchandra; Singh, Shishir H; Podar, Rajesh S; Kulkarni, Gaurav P; Babel, Shashank N

    2017-01-01

    Pulp sensitivity testing, even with its limitations and shortcomings, has been and still remains a very helpful aid in endodontic diagnosis. Pulp sensitivity tests extrapolate pulpal health from the sensory response. The aim of the present study was to identify the sensitivity, specificity, positive and negative predictive values (NPVs) of thermal and electrical tests of pulp sensitivity. Pulp tests studied were two cold and heat tests respectively and electrical test. A total of 330 teeth were tested: 198 teeth with vital pulp and 132 teeth with necrotic pulps (disease prevalence of 40%). The ideal standard was established by observing bleeding within the pulp chamber. Sensitivity values of the diagnostic tests were 0.89 and 0.94 for cold test, 0.84 and 0.87 for the heat tests, and 0.75 for electrical pulp test and the specificity values of the diagnostic tests were 0.91 and 0.93 for the cold tests, 0.86 and 0.84 for the heat tests, and 0.90 for electrical pulp test. The NPVs were 0.91 and 0.96 for the cold tests, 0.89 and 0.91 for the heat tests, and 0.84 for electrical pulp test. The positive predictive values were 0.89 and 0.90 for the cold tests, 0.80 and 0.79 for the heat tests and 0.88 for electrical pulp test. The highest accuracy (0.9393) was observed with cold test (icy spray). The cold test done with icy spray was the most accurate method for sensitivity testing.

  20. [Application of disparity discriminating accuracy test in evaluating the stereopsis of postoperative intermittent exotropia].

    PubMed

    Feng, L X; Yao, J Y; Chen, L; Tang, Y; Hou, F

    2016-08-01

    To discuss the application of disparity discriminating accuracy test in evaluating the stereopsis of postoperative intermittent exotropia. Patients with intermittent exotropia who underwent surgery during July 2011 to June 2013 were followed up. The stereoacuity was examined by Titmus Stereotest, Randot Stereotest and Frisby Stereotest. Twenty adult cases whose stereoacuity reached normal were chosen as experimental group. Twenty healthy adults were selected as normal control group. Both groups were examined with disparity discriminating accuracy test. Discriminating accuracy of the two groups were analyzed with Two-Way ANOVA method. Test-retest reliability was analyzed with Intraclass Correlation Coefficient analysis. The test-retest reliability of disparity discriminating accuracy test is excellent (ICC=0.99, P<0.01) . Discriminating accuracy under different disparities in experimental group were 0.56±0.09, 0.67±0.14, 0.77±0.15, 0.82±0.14, 0.85±0.11, 0.85±0.14, 0.87±0.10, 0.84±0.16, while those in control group were 0.77±0.09, 0.88±0.09, 0.93±0.08, 0.91±0.09, 0.95±0.08, 0.96±0.05, 0.97±0.06, 0.96±0.04. There were statistically significant differences between them (F=38.06, P<0.01) . The discriminating ability of group grating in both groups was affected by the size of disparity. Under situation of small disparity, a large difference was found between the experimental group (0.67±0.12)and control group(0.86±0.07) (F=4.84, P<0.05). Stereoscopic function can be evaluated comprehensively with disparity discriminating accuracy test. Use this test, a certain degree of dysfunction in stereopsis can still be found in postoperative intermittent exotropic patients who reached normal stereoacuity examined with traditional stereotests. (Chin J Ophthalmol, 2016, 52: 584-588).

Top