HOT CELL BUILDING, TRA632. FLOOR PLAN OF EXPANSION SHOWS LOCATION ...
HOT CELL BUILDING, TRA-632. FLOOR PLAN OF EXPANSION SHOWS LOCATION OF NEW CELLS, "HEAVY" CELL AT WEST END, "LIGHT" CELLS AT EAST. MOCK-UP AND STORAGE AREAS IN SOUTH HALF OF FLOOR. H.K. FERGUSON 895-MTR-ETR-632-A1, 12/1958. INL INDEX NO. 531-0632-00-279-101924, REV. 4. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
HOT CELL BUILDING, TRA632. FIRST FLOOR FOUNDATION PLAN SHOWS SECTIONALIZED ...
HOT CELL BUILDING, TRA-632. FIRST FLOOR FOUNDATION PLAN SHOWS SECTIONALIZED FLOOR LOADINGS AND CONCRETE SLAB THICKNESSES, A TYPICAL FEATURE OF NUCLEAR ARCHITECTURE. IDAHO OPERATIONS OFFICE MTR-632-IDO-2, 11/1952. INL INDEX NO. 531-0632-62-396-110561, REV. 1. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
LPT. Low power test (TAN640 and 641) floor plan. Cells ...
LPT. Low power test (TAN-640 and -641) floor plan. Cells 101 and 102, control rooms, shielded counting room, generator room, list of room numbers and names. Door details. Ralph M. Parsons 1229-12 ANP/GE-7-640-A-1. November 1956. Approved by INEEL Classification Office for public release. INEEL index code no. 038-0640-00-693-107274 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
5. ENGINE TEST CELL BUILDING INTERIOR. CENTRAL ROOM ON MAIN ...
5. ENGINE TEST CELL BUILDING INTERIOR. CENTRAL ROOM ON MAIN FLOOR. LOOKING NORTHWEST. - Fairchild Air Force Base, Engine Test Cell Building, Near intersection of Arnold Street & George Avenue, Spokane, Spokane County, WA
2012-09-01
suspended in the runoff waters around the lakebeds, sealing lakebed surface cracks and filling fissures. Shallow flooding along with consistent winds are...of the recorded specimens consist of isolated fragments of tooth enamel or bone that are not securely dated. Irvingtonian fossil localities have...require frequent repair as well. Concrete floors are cracking throughout all four test cells. Entry doors sag and drag on buckled floors. One-half
Laing, Andrew C; Robinovitch, Stephen N
2009-05-01
Low stiffness floors such as carpet appear to decrease hip fracture risk by providing a modest degree of force attenuation during falls without impairing balance. It is unknown whether other compliant floors can more effectively reduce impact loads without coincident increases in fall risk. We used a hip impact simulator to assess femoral neck force for four energy-absorbing floors (SmartCell, SofTile, Firm Foam, Soft Foam) compared to a rigid floor. We also assessed the influence of these floors on balance/mobility in 15 elderly women. We observed differences in the mean attenuation in peak femoral neck force provided by the SmartCell (24.5%), SofTile (47.2%), Firm Foam (76.6%), and Soft Foam (52.4%) floors. As impact velocity increased from 2 to 4m/s, force attenuation increased for SmartCell (from 17.3% to 33.7%) and SofTile (from 44.9% to 51.2%), but decreased for the Firm Foam (from 87.0% to 64.5%) and Soft Foam (from 66.1% to 37.9%) conditions. Regarding balance, there were no significant differences between the rigid, SmartCell, and SofTile floors in proportion of successful trials, Get Up and Go time, balance confidence or utility ratings. SofTile, Firm Foam, and Soft Foam caused significant increases (when compared to the rigid floor) in postural sway in the anterior-posterior and medial-lateral directions during standing. However, SmartCell increased sway only in the anterior-posterior direction. This study demonstrates that two commercially available compliant floors can attenuate femoral impact force by up to 50% while having only limited influence on balance in older women, and supports development of clinical trials to test their effectiveness in high-risk settings.
Comparing the field and laboratory emission cell (FLEC) with traditional emissions testing chambers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roache, N.F.; Guo, Z.; Fortmann, R.
1996-12-31
A series of tests was designed to evaluate the performance of the field and laboratory emission cell (FLEC) as applied to the testing of emissions from two indoor coating materials, floor wax and latex paint. These tests included validation of the repeatability of the test method, evaluation of the effect of different air velocities on source emissions, and a comparison of FLEC versus small chamber characterization of emissions. The FLEC exhibited good repeatability in characterization of emissions when applied to both sources under identical conditions. Tests with different air velocities showed significant effects on the emissions from latex paint, yetmore » little effect on emissions from the floor wax. Comparisons of data from the FLEC and small chamber show good correlation for measurements involving floor wax, but less favorable results for emissions from latex paint. The procedures and findings are discussed; conclusions are limited and include emphasis on the need for additional study and development of a standard method.« less
A&M. Hot cell addition (TAN633). Floor plan, elevations. Arrangement of ...
A&M. Hot cell addition (TAN-633). Floor plan, elevations. Arrangement of monorail along corridor, four hot cells, plug access openings, viewing windows, photo darkroom. Ralph M. Parsons 1229-13-ANP/GE-3-633-A-1. Date: December 1956 as redrawn in August 1998. Approved by INEEL Classification Office for public release. INEEL index code no. 034-0633-00-693-107315 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
A&M. TAN633. Hot cell floor plans, elevations, sections. Hole schedule ...
A&M. TAN-633. Hot cell floor plans, elevations, sections. Hole schedule (penetrations through concrete). Swing-door details. Ralph M. Parsons 1229-13-ANP/GE-3-633-A-3. Date: December 1956. Approved by INEEL Classification Office for public release. INNEL index code no. 034-0633-00-693-107317 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
21. Photocopy of engineering drawing, May, 1941 (original drawing located ...
21. Photocopy of engineering drawing, May, 1941 (original drawing located at Fairchild Air Force Base, Civil Engineering Building, Civil Engineering vault). ENGINE TEST CELL BUILDING. SECOND FLOOR PLAN, RIGHT AND LEFT END PORTIONS, TEST CELLS 5-12. - Fairchild Air Force Base, Engine Test Cell Building, Near intersection of Arnold Street & George Avenue, Spokane, Spokane County, WA
18. Photocopy of engineering drawing, May, 1941 (original drawing located ...
18. Photocopy of engineering drawing, May, 1941 (original drawing located at Fairchild Air Force Base, Civil Engineering Building, Civil Engineering vault). ENGINE TEST CELL BUILDING. FIRST FLOOR PLAN, CENTRAL PORTION AND TEST CELLS 1-4. - Fairchild Air Force Base, Engine Test Cell Building, Near intersection of Arnold Street & George Avenue, Spokane, Spokane County, WA
22. Photocopy of engineering drawing, May, 1941 (original drawing located ...
22. Photocopy of engineering drawing, May, 1941 (original drawing located at Fairchild Air Force Base, Civil Engineering Building, Civil Engineering vault). ENGINE TEST CELL BUILDING. THIRD FLOOR AND ROOF PLAN, CENTRAL PORTION AND TEST CELLS 1-4. - Fairchild Air Force Base, Engine Test Cell Building, Near intersection of Arnold Street & George Avenue, Spokane, Spokane County, WA
16. Photocopy of engineering drawing, May, 1941 (original drawing located ...
16. Photocopy of engineering drawing, May, 1941 (original drawing located at Fairchild Air Force Base, Civil Engineering Building, Civil Engineering vault). ENGINE TEST CELL BUILDING. BASEMENT FLOOR PLAN, CENTRAL PORTION AND TEST CELLS 1-4. - Fairchild Air Force Base, Engine Test Cell Building, Near intersection of Arnold Street & George Avenue, Spokane, Spokane County, WA
17. Photocopy of engineering drawing, May, 1941 (original drawing located ...
17. Photocopy of engineering drawing, May, 1941 (original drawing located at Fairchild Air Force Base, Civil Engineering Building, Civil Engineering vault). ENGINE TEST CELL BUILDING. BASEMENT FLOOR PLAN, RIGHT AND LEFT END PORTIONS, TEST CELLS 5-12. - Fairchild Air Force Base, Engine Test Cell Building, Near intersection of Arnold Street & George Avenue, Spokane, Spokane County, WA
20. Photocopy of engineering drawing, May, 1941 (original drawing located ...
20. Photocopy of engineering drawing, May, 1941 (original drawing located at Fairchild Air Force Base, Civil Engineering Building, Civil Engineering vault). ENGINE TEST CELL BUILDING. SECOND FLOOR PLAN, CENTRAL PORTION AND TEST CELLS 1-4. - Fairchild Air Force Base, Engine Test Cell Building, Near intersection of Arnold Street & George Avenue, Spokane, Spokane County, WA
19. Photocopy of engineering drawing, May, 1941 (original drawing located ...
19. Photocopy of engineering drawing, May, 1941 (original drawing located at Fairchild Air Force Base, Civil Engineering Building, Civil Engineering vault). ENGINE TEST CELL BUILDING. FIRST FLOOR PLAN, RIGHT AND LEFT END PORTIONS, TEST CELLS 5-12. - Fairchild Air Force Base, Engine Test Cell Building, Near intersection of Arnold Street & George Avenue, Spokane, Spokane County, WA
23. Photocopy of engineering drawing, May, 1941 (original drawing located ...
23. Photocopy of engineering drawing, May, 1941 (original drawing located at Fairchild Air Force Base, Civil Engineering Building, Civil Engineering vault). ENGINE TEST CELL BUILDING. THIRD FLOOR AND ROOF PLAN, RIGHT AND LEFT END PORTIONS, TEST CELLS 5-12. - Fairchild Air Force Base, Engine Test Cell Building, Near intersection of Arnold Street & George Avenue, Spokane, Spokane County, WA
31. INTERIOR VIEW TO THE EAST OF THE FIRST FLOOR ...
31. INTERIOR VIEW TO THE EAST OF THE FIRST FLOOR SOUTH CORRIDOR AND VIEWING GALLERY TO THE DISASSEMBLY BAY AND POST-MORTEM CELLS. VIEWING STATIONS ARE ON BOTH SIDES OF THE CORRIDOR. - Nevada Test Site, Reactor Maintenance Assembly & Dissassembly Facility, Area 25, Jackass Flats, Junction of Roads F & G, Mercury, Nye County, NV
41. Historic photo of Building 202 test cell interior, Robert ...
41. Historic photo of Building 202 test cell interior, Robert J. Gardener checking fuel implinging qualities of a twenty-thousand-pound-thrust rocket engine injector. Setting appears to be a platform mounted on top of scrubber tank underneath test cell floor, December 1959. On file at NASA Plumbrook Research Center, Sandusky, Ohio. NASA photo number C-52166. - Rocket Engine Testing Facility, GRC Building No. 202, NASA Glenn Research Center, Cleveland, Cuyahoga County, OH
Lachance, Chantelle C; Korall, Alexandra M B; Russell, Colin M; Feldman, Fabio; Robinovitch, Stephen N; Mackey, Dawn C
2018-09-01
Purpose-designed compliant flooring and carpeting have been promoted as a means for reducing fall-related injuries in high-risk environments, such as long-term care. However, it is not known whether these surfaces influence the forces that long-term care staff exert when pushing residents in wheelchairs. We studied 14 direct-care staff who pushed a loaded wheelchair instrumented with a triaxial load cell to test the effects on hand force of flooring overlay (vinyl versus carpet) and flooring subfloor (concrete versus compliant rubber [brand: SmartCells]). During straight-line pushing, carpet overlay increased initial and sustained hand forces compared to vinyl overlay by 22-49% over a concrete subfloor and by 8-20% over a compliant subfloor. Compliant subflooring increased initial and sustained hand forces compared to concrete subflooring by 18-31% when under a vinyl overlay. In contrast, compliant flooring caused no change in initial or sustained hand forces compared to concrete subflooring when under a carpet overlay. Copyright © 2018 Elsevier Ltd. All rights reserved.
29. Photocopy of engineering drawing, May, 1941 (original drawing located ...
29. Photocopy of engineering drawing, May, 1941 (original drawing located at Fairchild Air Force Base, Civil Engineering Building, Civil Engineering vault). ENGINE TEST CELL BUILDING. 19508 RENOVATION OF FIRST FLOOR, CENTRAL PORTION. - Fairchild Air Force Base, Engine Test Cell Building, Near intersection of Arnold Street & George Avenue, Spokane, Spokane County, WA
Wang, W; Wideman, R F; Chapman, M E; Bersi, T K; Erf, G F
2003-12-01
Commercial broilers are constantly exposed to airborne microorganisms and endotoxin (lipopolysaccharide, LPS). It has been shown that microbial contamination of the air was higher in broiler houses using floor litter than in broiler houses using netting-type floors. The current study evaluated the effect of housing conditions on blood leukocyte profiles and tested the hypothesis that, when compared to broilers reared in clean stainless steel cages (Cage group), broilers raised on floor litter (Floor group) should experience a higher environmental challenge and have a desensitized immune system that may exhibit better tolerance/resistance to subsequent intravenous LPS challenge. Hematological parameters were evaluated prior to and following i.v. administration of 1 mg/kg BW Salmonella typhimurium LPS (dissolved at 1 mg/0.25 mL in PBS) or i.v. injection of 0.25 mL/kg BW PBS alone. The results showed that prior to LPS/PBS injection, broilers in the cage group had higher heterophil and monocyte concentrations, a higher B cell percentage within the lymphocyte population, and a higher heterophil to lymphocyte (H:L) ratio in the blood. The i.v. LPS injection resulted in 25% mortality in the cage group and 42% mortality in the floor group within 8 h post-injection. LPS reduced the concentrations of total white blood cells (WBC) and all differential WBC except eosinophils and increased thrombocyte concentrations within 1 h post-injection in both groups. All of these values returned to their respective pre-injection levels within 48 h post-injection in the surviving birds. The two groups exhibited similar overall hematological changes after LPS injection except that the cage group showed a higher H:L ratio at 8 h post-injection and a lower B-cell percentage within the lymphocyte population at 48 h post-injection when compared with the floor group. We concluded that the immune systems of broilers reared on floor litter were desensitized and exhibited less pronounced leukocyte responses to i.v. LPS when compared with those of broilers reared in clean stainless steel cages. However, such desensitization of the immune system did not help broilers survive subsequent i.v. LPS challenge.
Structural Element Tests in Support of the Keyworker Blast Shelter Program
1985-10-01
forced concrete -lab with two transverse reinforced concrete floor beams to transfer the interior column loads to the floor slab. Using a roof slab... lateral buck- "-4 ling; however, this could have occurred after a column buckled and the roof collapsed. Since load cell 2 (middle column ) recorded the...ANALYSIS OF FREE-FIELD AND STRUCTURE LOADING DATA ... ........ .. 102 6.1.1 Loading Wave Velocity ........... .................... ... 102 6.1.2 Lateral
NASA Astrophysics Data System (ADS)
Hyun, Seung; Kwon, Owoong; Lee, Bom-Yi; Seol, Daehee; Park, Beomjin; Lee, Jae Yong; Lee, Ju Hyun; Kim, Yunseok; Kim, Jin Kon
2016-01-01
Multiple data writing-based multi-level non-volatile memory has gained strong attention for next-generation memory devices to quickly accommodate an extremely large number of data bits because it is capable of storing multiple data bits in a single memory cell at once. However, all previously reported devices have failed to store a large number of data bits due to the macroscale cell size and have not allowed fast access to the stored data due to slow single data writing. Here, we introduce a novel three-dimensional multi-floor cascading polymeric ferroelectric nanostructure, successfully operating as an individual cell. In one cell, each floor has its own piezoresponse and the piezoresponse of one floor can be modulated by the bias voltage applied to the other floor, which means simultaneously written data bits in both floors can be identified. This could achieve multi-level memory through a multiple data writing process.Multiple data writing-based multi-level non-volatile memory has gained strong attention for next-generation memory devices to quickly accommodate an extremely large number of data bits because it is capable of storing multiple data bits in a single memory cell at once. However, all previously reported devices have failed to store a large number of data bits due to the macroscale cell size and have not allowed fast access to the stored data due to slow single data writing. Here, we introduce a novel three-dimensional multi-floor cascading polymeric ferroelectric nanostructure, successfully operating as an individual cell. In one cell, each floor has its own piezoresponse and the piezoresponse of one floor can be modulated by the bias voltage applied to the other floor, which means simultaneously written data bits in both floors can be identified. This could achieve multi-level memory through a multiple data writing process. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr07377d
Hyun, Seung; Kwon, Owoong; Lee, Bom-Yi; Seol, Daehee; Park, Beomjin; Lee, Jae Yong; Lee, Ju Hyun; Kim, Yunseok; Kim, Jin Kon
2016-01-21
Multiple data writing-based multi-level non-volatile memory has gained strong attention for next-generation memory devices to quickly accommodate an extremely large number of data bits because it is capable of storing multiple data bits in a single memory cell at once. However, all previously reported devices have failed to store a large number of data bits due to the macroscale cell size and have not allowed fast access to the stored data due to slow single data writing. Here, we introduce a novel three-dimensional multi-floor cascading polymeric ferroelectric nanostructure, successfully operating as an individual cell. In one cell, each floor has its own piezoresponse and the piezoresponse of one floor can be modulated by the bias voltage applied to the other floor, which means simultaneously written data bits in both floors can be identified. This could achieve multi-level memory through a multiple data writing process.
HOT CELL BUILDING, TRA632, INTERIOR. DETAIL OF HOT CELL NO. ...
HOT CELL BUILDING, TRA-632, INTERIOR. DETAIL OF HOT CELL NO. 2 SHOWS MANIPULATION INSTRUMENTS AND SHIELDED OPERATING WINDOWS. PENETRATIONS FOR OPERATING INSTRUMENTS GO THROUGH SHIELDING ABOVE WINDOWS. CONDUIT FOR UTILITIES AND CONTROLS IS BEHIND METAL CABINET BELOW WINDOWS NEAR FLOOR. CAMERA FACES WEST. WARNING SIGN LIMITS FISSILE MATERIAL TO SPECIFIED NUMBER OF GRAMS OF URANIUM AND PLUTONIUM. INL NEGATIVE NO. HD46-28-2. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Tian, Jing; Yam, Caleb; Balasundaram, Gayathri; Wang, Hui; Gore, Aniket; Sampath, Karuna
2003-07-01
The floor plate, a specialized group of cells in the ventral midline of the neural tube of vertebrates, plays crucial roles in patterning the central nervous system. Recent work from zebrafish, chick, chick-quail chimeras and mice to investigate the development of the floor plate have led to several models of floor-plate induction. One model suggests that the floor plate is formed by inductive signalling from the notochord to the overlying neural tube. The induction is thought to be mediated by notochord-derived Sonic hedgehog (Shh), a secreted protein, and requires direct cellular contact between the notochord and the neural tube. Another model proposes a role for the organizer in generating midline precursor cells that produce floor plate cells independent of notochord specification, and proposes that floor plate specification occurs early, during gastrulation. We describe a temperature-sensitive mutation that affects the zebrafish Nodal-related secreted signalling factor, Cyclops, and use it to address the issue of when the floor plate is induced in zebrafish. Zebrafish cyclops regulates the expression of shh in the ventral neural tube. Although null mutations in cyclops result in the lack of the medial floor plate, embryos homozygous for the temperature-sensitive mutation have floor plate cells at the permissive temperature and lack floor plate cells at the restrictive temperature. We use this mutant allele in temperature shift-up and shift-down experiments to answer a central question pertaining to the timing of vertebrate floor plate induction. Abrogation of Cyc/Nodal signalling in the temperature-sensitive mutant embryos at various stages indicates that the floor plate in zebrafish is induced early in development, during gastrulation. In addition, continuous Cyclops signalling is required through gastrulation for a complete ventral neural tube throughout the length of the neuraxis. Finally, by modulation of Nodal signalling levels in mutants and in ectopic overexpression experiments, we show that, similar to the requirements for prechordal plate mesendoderm fates, uninterrupted and high levels of Cyclops signalling are required for induction and specification of a complete ventral neural tube.
The influence of novel compliant floors on balance control in elderly women--A biomechanical study.
Wright, Alexander D; Laing, Andrew C
2011-07-01
Novel compliant floors aim to decrease the risk for fall-related injury by providing substantial force attenuation during the impact phase of falls. Certain models of compliant flooring have been shown to have limited influence on postural sway and successful completion of dynamic balance tasks. However, the effects of these products on balance recovery mechanisms following an externally induced perturbation have yet to be quantified. We used a floor translation paradigm to induce a balance perturbation to thirteen elderly community-dwelling women. Outcome measures included the displacement rates and margins of safety for both the underfoot centre-of-pressure and whole-body centre-of-mass across two novel compliant floors (SmartCell, SofTile), two basic foam surfaces (Firm-Foam, Soft-Foam) and a standard 'Rigid' floor as a control condition. The centre-of-mass and centre-of-pressure margins of safety, and all centre-of-mass displacement rates, were not significantly lower for the two novel compliant flooring systems compared to the control floor. The centre-of-pressure displacement rates were similar to the control floor for the SmartCell floor condition. The majority of the margin of safety and displacement rate variables for the foam floors were significantly lower than the control condition. This study illustrates that the SmartCell and SofTile novel compliant floors have minimal influences on balance and balance control responses following externally induced perturbations in older community-dwelling women, and supports pilot installations of these floors to inform decisions regarding the development of clinical trials. Crown Copyright © 2011. Published by Elsevier Ltd. All rights reserved.
The influence of novel compliant floors on balance control in elderly women—A biomechanical study
Wright, Alexander D.; Laing, Andrew C.
2012-01-01
Novel compliant floors aim to decrease the risk for fall-related injury by providing substantial force attenuation during the impact phase of falls. Certain models of compliant flooring have been shown to have limited influence on postural sway and successful completion of dynamic balance tasks. However, the effects of these products on balance recovery mechanisms following an externally induced perturbation have yet to be quantified. We used a floor translation paradigm to induce a balance perturbation to thirteen elderly community-dwelling women. Outcome measures included the displacement rates and margins of safety for both the underfoot centre-of-pressure and whole-body centre-of-mass across two novel compliant floors (Smart-Cell, SofTile), two basic foam surfaces (Firm-Foam, Soft-Foam) and a standard ‘Rigid’ floor as a control condition. The centre-of-mass and centre-of-pressure margins of safety, and all centre-of-mass displacement rates, were not significantly lower for the two novel compliant flooring systems compared to the control floor. The centre-of-pressure displacement rates were similar to the control floor for the SmartCell floor condition. The majority of the margin of safety and displacement rate variables for the foam floors were significantly lower than the control condition. This study illustrates that the SmartCell and SofTile novel compliant floors have minimal influences on balance and balance control responses following externally induced perturbations in older community-dwelling women, and supports pilot installations of these floors to inform decisions regarding the development of clinical trials. PMID:21545881
FLOOR PLAN OF MAIN PROCESSING BUILDING (CPP601), SECOND FLOOR SHOWING ...
FLOOR PLAN OF MAIN PROCESSING BUILDING (CPP-601), SECOND FLOOR SHOWING PROCESS MAKEUP AREA AND EIGHTEEN CELLS AND ADJOINING REMOTE ANALYTICAL FACILITY (CPP-627) SHOWING COLD LAB, DECONTAMINATION ROOM, MULTICURIE CELL ROOM, AND OFFICES. TO LEFT ARE LABORATORY BUILDING (CPP-602) AND MAINTENANCE BUILDING (CPP-630). INL DRAWING NUMBER 200-0601-00-706-051980. ALTERNATE ID NUMBER CPP-E-1980. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
FLOOR PLAN OF MAIN PROCESSING BUILDING (CPP601), FIRST FLOOR SHOWING ...
FLOOR PLAN OF MAIN PROCESSING BUILDING (CPP-601), FIRST FLOOR SHOWING SAMPLE CORRIDORS AND EIGHTEEN CELLS AND ADJOINING REMOTE ANALYTICAL FACILITY (CPP-627) SHOWING REMOTE ANALYTICAL FACILITIES LAB, DECONTAMINATION ROOM, AND MULTICURIE CELL ROOM. TO LEFT ARE LABORATORY BUILDING (CPP-602) AND MAINTENANCE BUILDING (CPP-630). INL DRAWING NUMBER 200-0601-00-706-051979. ALTERNATE ID NUMBER CPP-E-1979. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
Crashworthy airframe design concepts: Fabrication and testing
NASA Technical Reports Server (NTRS)
Cronkhite, J. D.; Berry, V. L.
1982-01-01
Crashworthy floor concepts applicable to general aviation aircraft metal airframe structures were investigated. Initially several energy absorbing lower fuselage structure concepts were evaluated. Full scale floor sections representative of a twin engine, general aviation airplane lower fuselage structure were designed and fabricated. The floors featured an upper high strength platform with an energy absorbing, crushable structure underneath. Eighteen floors were fabricated that incorporated five different crushable subfloor concepts. The floors were then evaluated through static and dynamic testing. Computer programs NASTRAN and KRASH were used for the static and dynamic analysis of the floor section designs. Two twin engine airplane fuselages were modified to incorporate the most promising crashworthy floor sections for test evaluation.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-24
... That Would Not Permit Floor Brokers To Use Personal Portable Phone Devices on the Trading Floor Due to the Unavailability of Exchange-Provided Cell Phones on September 11, 2013 September 18, 2013. Pursuant... personal portable phone devices on the Trading Floor due to the unavailability of Exchange-provided cell...
Inohaya, Keiji; Takano, Yoshiro; Kudo, Akira
2010-06-01
The floor plate is a key organizer that controls the specification of neurons in the central nervous system. Here, we show a new role of the floor plate: segmental pattern formation of the vertebral column. Analysis of a spontaneous medaka mutant, fused centrum (fsc), which exhibits fused centra and the absence of the intervertebral ligaments, revealed that fsc encodes wnt4b, which was expressed exclusively in the floor plate. In fsc mutants, we found that wnt4b expression was completely lost in the floor plate and that abnormal conversion of the intervertebral ligament cells into osteoblasts appeared to cause a defect of the intervertebral ligaments. The establishment of the transgenic rescue lines and mosaic analyses allowed the conclusion to be drawn that production of wnt4b by floor plate cells is essential for the segmental patterning of the vertebral column. Our findings provide a novel perspective on the mechanism of vertebrate development.
Physical and chemical test results of electrostatic safe flooring materials
NASA Technical Reports Server (NTRS)
Gompf, R. H.
1988-01-01
This test program was initiated because a need existed at the Kennedy Space Center (KSC) to have this information readily available to the engineer who must make the choice of which electrostatic safe floor to use in a specific application. The information, however, should be of value throughout both the government and private industry in the selection of a floor covering material. Included are the test results of 18 floor covering materials which by test evaluation at KSC are considered electrostatically safe. Tests were done and/or the data compiled in the following areas: electrostatics, flammability, hypergolic compatibility, outgassing, floor type, material thickness, and available colors. Each section contains the test method used to gather the data and the test results.
Celiker Tosun, O; Kaya Mutlu, E; Ergenoglu, A M; Yeniel, A O; Tosun, G; Malkoc, M; Askar, N; Itil, I M
2015-06-01
To determine whether symptoms of urinary incontinence is reduced by pelvic floor muscle training, to determine whether urinary incontinence can be totally eliminated by strengthening the pelvic floor muscle to grade 5 on the Oxford scale. Prospective randomized controlled clinical trial. Outpatient urogynecology department. One hundred thirty cases with stress and mixed urinary incontinence. All participants were randomly allocated to the pelvic floor muscle training group or control group. A 12-week home based exercise program, prescribed individually, was performed by the pelvic floor muscle training group. Urinary incontinence symptoms (Incontinence Impact Questionnaire-7, Urogenital Distress Inventory-6, bladder diary, stop test and pad test) were assessed, and the pelvic floor muscle strength was measured for (PERFECT testing, perineometric and ultrasound) all participants before and after 12 weeks of treatment. The pelvic floor muscle training group had significant improvement in their symptoms of urinary incontinence (P=0.001) and an increase in pelvic floor muscle strength (P=0.001, by the dependent t test) compared with the control group. All the symptoms of urinary incontinence were significantly decreased in the patients that had reached pelvic floor muscle strength of grade 5 and continued the pelvic floor muscle training (P<0.05). The study demonstrated that pelvic floor muscle training is effective in reducing the symptoms of stress and mixed urinary incontinence and in increasing pelvic floor muscle strength. © The Author(s) 2014.
Tosun, Ozge Celiker; Solmaz, Ulas; Ekin, Atalay; Tosun, Gokhan; Gezer, Cenk; Ergenoglu, Ahmet Mete; Yeniel, Ahmet Ozgur; Mat, Emre; Malkoc, Mehtap; Askar, Niyazi
2016-01-01
[Purpose] The aim of this study was to evaluate whether the effect of pelvic floor exercises on pelvic floor muscle strength could be detected via ultrasonography in patients with urinary incontinence. [Subjects and Methods] Of 282 incontinent patients, 116 participated in the study and were randomly divided into a pelvic floor muscle training (n=65) group or control group (n=51). The pelvic floor muscle training group was given pelvic floor exercise training for 12 weeks. Both groups were evaluated at the beginning of the study and after 12 weeks. Abdominal ultrasonography measurements in transverse and longitudinal planes, the PERFECT scheme, perineometric evaluation, the stop test, the stress test, and the pad test were used to assess pelvic floor muscle strength in all cases. [Results] After training, the PERFECT, perineometry and transabdominal ultrasonography measurements were found to be significantly improved, and the stop test and pad test results were significantly decreased in the pelvic floor muscle training group, whereas no difference was observed in the control group. There was a positive correlation between the PERFECT force measurement scale and ultrasonography force measurement scale before and after the intervention in the control and pelvic floor muscle training groups (r=0.632 and r=0.642, respectively). [Conclusion] Ultrasonography can be used as a noninvasive method to identify the change in pelvic floor muscle strength with exercise training. PMID:27065519
ETR ELECTRICAL BUILDING, TRA648. FLOOR PLANS FOR FIRST FLOOR AND ...
ETR ELECTRICAL BUILDING, TRA-648. FLOOR PLANS FOR FIRST FLOOR AND BASEMENT. SECTIONS. KAISER ETR-5528-MTR-648-A-2, 12/1955. INL INDEX NO. 532-0648-00-486-101402, REV. 6. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
ETR, TRA642. FLOOR PLAN UNDER BALCONY ON CONSOLE FLOOR. MOTORGENERATOR ...
ETR, TRA-642. FLOOR PLAN UNDER BALCONY ON CONSOLE FLOOR. MOTOR-GENERATOR SETS AND OTHER ELECTRICAL EQUIPMENT. PHILLIPS PETROLEUM COMPANY ETR-D-1781, 7/1960. INL INDEX NO. 532-0642-00-706-020384, REV. 1. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
EVAPORATOR FLOOR, CELL ONE IN FOREGROUND, CRYSTALLIZER MEZZANINE TO REAR, ...
EVAPORATOR FLOOR, CELL ONE IN FOREGROUND, CRYSTALLIZER MEZZANINE TO REAR, OLIVER MUD FILTER WING TO RIGHT REAR. VIEW FROM NORTHEAST - Lihue Plantation Company, Sugar Mill Building, Haleko Road, Lihue, Kauai County, HI
Migration of DEHP and DINP into dust from PVC flooring products at different surface temperature.
Jeon, Seunghwan; Kim, Ki-Tae; Choi, Kyungho
2016-03-15
Phthalates are important endocrine disrupting chemicals that have been linked to various adverse human health effects. Phthalates are ubiquitously present in indoor environment and could enter humans. Vinyl or PVC floorings have been recognized as one of important sources of phthalate release to indoor environment including house dust. In the present study, we estimated the migration of di(2-ethylhexyl)phthalate (DEHP) and di-isononyl phthalate (DINP) from the flooring materials into the dust under different heating conditions. For this purpose, a small chamber specifically designed for the present study and a Field and Laboratory Emission Cell (FLEC) were used, and four major types of PVC flooring samples including two UV curing paint coated, an uncoated residential, and a wax-coated commercial type were tested. Migration of DEHP was observed for an uncoated residential type and a wax-coated commercial type flooring. After 14 days of incubation, the levels of DEHP in the dust sample was determined at room temperature on average (standard deviation) at 384 ± 19 and 481 ± 53 μg/g, respectively. In contrast, migration of DINP was not observed. The migration of DEHP was strongly influenced by surface characteristics such as UV curing coating. In the residential flooring coated with UV curing paint, migration of DEHP was not observed at room temperature. But under the heated condition, the release of DEHP was observed in the dust in the FLEC. Migration of DEHP from flooring materials increased when the flooring was heated (50 °C). In Korea, heated flooring system, or 'ondol', is very common mode of heating in residential setting, therefore the contribution of PVC flooring to the total indoor DEHP exposure among general population is expected to be greater especially during winter season when the floor is heated. Copyright © 2015 Elsevier B.V. All rights reserved.
Impact evaluation of composite floor sections
NASA Technical Reports Server (NTRS)
Boitnott, Richard L.; Fasanella, Edwin L.
1989-01-01
Graphite-epoxy floor sections representative of aircraft fuselage construction were statically and dynamically tested to evaluate their response to crash loadings. These floor sections were fabricated using a frame-stringer design typical of present aluminum aircraft without features to enhance crashworthiness. The floor sections were tested as part of a systematic research program developed to study the impact response of composite components of increasing complexity. The ultimate goal of the research program is to develop crashworthy design features for future composite aircraft. Initially, individual frames of six-foot diameter were tested both statically and dynamically. The frames were then used to construct built-up floor sections for dynamic tests at impact velocities of approximately 20 feet/sec to simulate survivable crash velocities. In addition, static tests were conducted to gain a better understanding of the failure mechanisms seen in the dynamic tests.
Gait of dairy cows on floors with different slipperiness.
Telezhenko, E; Magnusson, M; Bergsten, C
2017-08-01
This study assessed the slip resistance of different types of solid flooring in cattle housing using a range of technical tests and gait analysis. Dynamic and static coefficient of friction, skid resistance, and abrasiveness were tested on concrete flooring with a smooth finish, a grooved pattern, or a tamped pattern, acid-resistant mastic asphalt, soft rubber mats, and a worn slatted concrete floor. Coefficients of friction and skid resistance were tested under clean and slurry-soiled conditions. Linear kinematic variables were assessed in 40 cows with trackway measurements after the cows passed over the floors in a straight walk. All gait variables were assessed as deviations from those obtained on the slatted concrete floor, which was used as a baseline. The coefficient of friction tests divided the floors into 3 categories: concrete flooring, which had a low coefficient of friction (0.29-0.41); mastic asphalt flooring, which had medium values (0.38-0.45); and rubber mats, which had high values (0.49-0.57). The highest abrasion (g/10 m) was on the asphalt flooring (4.48), and the concrete flooring with a tamped pattern had significantly higher abrasiveness (2.77) than the other concrete floors (1.26-1.60). Lowest values on the skid-resistance tests (dry/wet) were for smooth concrete (79/35) and mastic asphalt (65/47), especially with a slurry layer on the surface. Gait analysis mainly differentiated floors with higher friction and abrasion by longer strides and better tracking. Step asymmetry was lower on floors with high skid-resistance values. The most secure cow gait, in almost every aspect, was observed on soft rubber mats. Relationships between gait variables and physical floor characteristics ranged from average to weak (partial correlations 0.54-0.16). Thus, none of the physical characteristics alone was informative enough to characterize slip resistance. With reference to gait analysis, the abrasiveness of the hard surfaces was more informative than the coefficient of friction, but the effect of pattern was better detected by skid-resistance measurements. Consequently, several physical characteristics are needed to objectively describe the slip resistance of cattle floors. Soft rubber mats gave better tracking than hard, solid floors, even with a grooved surface or a tamped pattern. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Experimental Verification of an Instrument to Test Flooring Materials
NASA Astrophysics Data System (ADS)
Philip, Rony; Löfgren, Hans, Dr
2018-02-01
The focus of this work is to validate the fluid model with different flooring materials and the measurements of an instrument to test flooring materials and its force attenuating capabilities using mathematical models to describe the signature and coefficients of the floor. The main contribution of the present work focus on the development of a mathematical fluid model for floors. The aim of the thesis was to analyze, compare different floor materials and to study the linear dynamics of falling impacts on floors. The impact of the hammer during a fall is captured by an accelerometer and response is collected using a picoscope. The collected data was analyzed using matlab least square method which is coded as per the fluid model. The finding from this thesis showed that the fluid model works with more elastic model but it doesn’t work for rigid materials like wood. The importance of parameters like velocity, mass, energy loss and other coefficients of floor which influences the model during the impact of falling on floors were identified and a standardized testing method was set.
Kahn Bani Sa’ad Correctional Facility, Kahn Bani Sa’ad, Iraq
2008-07-25
building (Building No. 07/03): 1. Ground floor columns were tested with a Schmidt hammer devise (measures the elastic properties or strength of...3. First floor columns – Schmidt hammer and ultrasonic tests were conducted on all the first floor columns. The test results showed the strength...Building Nos. 07/02 and 07/01): 1. Ground floor columns – Using a Schmidt hammer device, very few columns showed low strength. Further study and
30. GENERAL TEST ROOM IN 1946 ADDITION, FOURTH FLOOR, LOOKING ...
30. GENERAL TEST ROOM IN 1946 ADDITION, FOURTH FLOOR, LOOKING WEST. ORIGINALLY HAD SUSPENDED ACOUSTICAL CEILINGS WITH FLOURESCENT LIGHTING AND ASPHALT MASTIC TILE FLOORS - Underwriters' Laboratories, 207-231 East Ohio Street, Chicago, Cook County, IL
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-24
...--Equities That Would Not Permit Floor Brokers to Use Personal Portable Phone Devices on the Trading Floor Due to the Unavailability of Exchange-Provided Cell Phones on September 11, 2013 September 18, 2013... Floor brokers to use personal portable phone devices on the Trading Floor due to the unavailability of...
11. VIEW OF INTERIOR OF BUILDING 220 FIRST FLOOR, CELL ...
11. VIEW OF INTERIOR OF BUILDING 220 FIRST FLOOR, CELL BLOCK 'A' (SOLITARY CONFINEMENT CELL BLOCK), TYPICAL SOLITARY CONFINEMENT CELL. THE CELL SHOWN IN CENTER OF PHOTO, HAS A 2-1/2' THICK STEEL DOOR. THE CELL SHOWN IN THE LEFT OF PHOTO, HAS A 3/4' DIAMETER IRON GRILLE DOOR. - U.S. Naval Base, Pearl Harbor, Brig, Neville Way near Ninth Street at Marine Barracks, Pearl City, Honolulu County, HI
33. INTERIOR VIEW TO THE SOUTHWEST OF ROOM 135, A ...
33. INTERIOR VIEW TO THE SOUTHWEST OF ROOM 135, A FIRST FLOOR CORRIDOR AND VIEWING GALLERY NEXT TO THE POST-MORTEM CELLS. VIEWING AND WORK STATIONS ARE ON THE WEST WALL. - Nevada Test Site, Reactor Maintenance Assembly & Dissassembly Facility, Area 25, Jackass Flats, Junction of Roads F & G, Mercury, Nye County, NV
What Will Science Gain From Mapping the World Ocean Floor?
NASA Astrophysics Data System (ADS)
Jakobsson, M.
2017-12-01
It is difficult to estimate how much of the World Ocean floor topography (bathymetry) that has been mapped. Estimates range from a few to more than ten percent of the World Ocean area. The most recent version of the bathymetric grid compiled by the General Bathymetric Chart of the Oceans (GEBCO) has bathymetric control points in 18% of the 30 x 30 arc second large grid cells. The depth values for the rest of the cells are obtained through interpolation guided by satellite altimetry in deep water. With this statistic at hand, it seems tenable to suggest that there are many scientific discoveries to be made from a complete high-resolution mapping of the World Ocean floor. In this presentation, some of our recent scientific discoveries based on modern multibeam bathymetric mapping will be highlighted and discussed. For example, how multibeam mapping provided evidence for a km-thick ice shelf covering the entire Arctic Ocean during peak glacial conditions, a hypothesis proposed nearly half a century ago, and how groundwater escape features are visible in high-resolution bathymetry in the Baltic Sea, with potential implications for the freshwater budget and distribution of nutrients and pollutants. Presented examples will be placed in the context of mapping resolution, systematic surveys versus mapping along transits, and scientific hypothesis driven mapping versus ocean exploration. The newly announced Nippon Foundation - GEBCO Seabed 2030 project has the vision to map 100% of the World Ocean floor mapped by 2030. Are there specific scientific areas where we can expect new discoveries from all mapping data collected through the Seabed 2030 project? Are there outstanding hypothesis that can be tested from a fully mapped World Ocean floor?
Evaluation of Floors and Item Gradients for Reading and Math Tests for Young Children
ERIC Educational Resources Information Center
Bradley-Johnson, Sharon; Durmusoglu, Gokce
2005-01-01
Ignoring the adequacy of floors and item gradients for tests used with young children can have serious consequences. Thus, because of the importance of early intervention for reading and math problems, we used the criteria suggested by Bracken for adequate floors and item gradients, and reviewed 15 reading tests and 12 math tests for ages 4-0…
Growth of cultured corneal endothelial cells onto a vitreous carbon matrix.
Wickham, M G; Cleveland, P H; Binder, P S; Akers, P H
1983-01-01
Fourth passage cells of a rabbit corneal endothelial line were grown for 1 week in flasks containing pieces of a reticulated vitreous carbon matrix. The rate of cell growth in flasks containing the matrix was consistent with that in control flasks. Small fragments of the vitreous carbon material lying on the flask floor were covered by the monolayers as the cells grew to confluency. Vertical growth of cells onto larger pieces of the matrix proceeded in a staged fashion with maximum cell density on pieces of the matrix closest to the floor of the flask. As defined by scanning electron microscopy, cell growth occurred to a level at least 600 microns above the floor of the flask and the confluent monolayer. This novel culture procedure should be a model situation for study of many different aspects of the in vitro capabilities of corneal endothelial cells.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Mercury Vapor Measurement and Cell Room Monitoring Plans 5 Table 5 to Subpart IIIII of Part 63 Protection... Hazardous Air Pollutants: Mercury Emissions From Mercury Cell Chlor-Alkali Plants Pt. 63, Subpt. IIIII... and Cell Room Monitoring Plans Your Floor-Level Mercury Vapor Measurement Plan required by § 63.8192(d...
Code of Federal Regulations, 2013 CFR
2013-07-01
... Mercury Vapor Measurement and Cell Room Monitoring Plans 5 Table 5 to Subpart IIIII of Part 63 Protection... Hazardous Air Pollutants: Mercury Emissions From Mercury Cell Chlor-Alkali Plants Pt. 63, Subpt. IIIII... and Cell Room Monitoring Plans Your Floor-Level Mercury Vapor Measurement Plan required by § 63.8192(d...
Code of Federal Regulations, 2012 CFR
2012-07-01
... Mercury Vapor Measurement and Cell Room Monitoring Plans 5 Table 5 to Subpart IIIII of Part 63 Protection... Hazardous Air Pollutants: Mercury Emissions From Mercury Cell Chlor-Alkali Plants Pt. 63, Subpt. IIIII... and Cell Room Monitoring Plans Your Floor-Level Mercury Vapor Measurement Plan required by § 63.8192(d...
Code of Federal Regulations, 2014 CFR
2014-07-01
... Mercury Vapor Measurement and Cell Room Monitoring Plans 5 Table 5 to Subpart IIIII of Part 63 Protection... Hazardous Air Pollutants: Mercury Emissions From Mercury Cell Chlor-Alkali Plants Pt. 63, Subpt. IIIII... and Cell Room Monitoring Plans Your Floor-Level Mercury Vapor Measurement Plan required by § 63.8192(d...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Mercury Vapor Measurement and Cell Room Monitoring Plans 5 Table 5 to Subpart IIIII of Part 63 Protection... Hazardous Air Pollutants: Mercury Emissions From Mercury Cell Chlor-Alkali Plants Pt. 63, Subpt. IIIII... and Cell Room Monitoring Plans Your Floor-Level Mercury Vapor Measurement Plan required by § 63.8192(d...
Crane, Barbara; Goodworth, Adam D; Liquori, Melissa; Ghosh, Suhash; Certo, Catherine; McCafferty, Lorraine
2016-09-01
A major improvement in hospital safety could be realized if serious injury did not accompany falls. We studied several commercially available floor pads made of different materials to determine which (if any) would be practical in a hospital room and reduce injury without posing a threat to the balance of patients. A multidisciplinary approach was undertaken to (1) measure upper and lower body motion in 17 young (<50 years) and 17 older (>55 years) adults during an instrumented sit to stand test from a hospital bed onto the different floor pads, (2) predict the energy dissipation available in floor pads by quantifying the relative mechanical properties, and (3) obtain professional feedback from hospital nurses via a questionnaire (8 questions) following a period of working on the different floor pads. Five floor pads, composed of foam, gel, and/or rubber were tested. All pads were compared with a typical hospital floor (concrete covered with linoleum tiles, considered the control). All of the pads subject to mechanical testing showed at least 3 times more energy absorption compared with the control. Balance testing showed that three of the pads resulted in minimal or no significant increases in body motion during sit-to-stand. Nursing feedback revealed that only 2 of these 3 pads may be feasible for hospital room use: one made primarily of firm rubber and one made of foam. Floor pads do exist that show promise for hospital use that absorbing energy without major impacts on balance during sit-to-stand. Although only commercially available pads were investigated, results may inform the design and multidisciplinary testing of other floor surfaces.
PROCESS WATER BUILDING, TRA605, INTERIOR. FIRST FLOOR. CAMERA IS IN ...
PROCESS WATER BUILDING, TRA-605, INTERIOR. FIRST FLOOR. CAMERA IS IN SOUTHEAST CORNER AND FACES NORTHWEST. CONTROL ROOM AT RIGHT. CRANE MONORAIL IS OVER FLOOR HATCHES AND FLOOR OPENINGS. SIX VALVE HANDWHEELS ALONG FAR WALL IN LEFT CENTER VIEW. SEAL TANK IS ON OTHER SIDE OF WALL; PROCESS WATER PIPES ARE BELOW VALVE WHEELS. NOTE CURBS AROUND FLOOR OPENINGS. INL NEGATIVE NO. HD46-26-3. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
NASA Astrophysics Data System (ADS)
Su, Rose Mary; Tocci, Gregory
2005-09-01
The measurement of the Impact Insulation Class (IIC) rating of any floor/ceiling construction requires the use of a certified laboratory space. In a recent investigation into the IIC rating of a new floor system, several tests were conducted in a certified laboratory. In many tests, the IIC rating was controlled by the 100-Hz 1/3-octave frequency band, despite changes in the floor/ceiling construction. The base floor/ceiling construction included a wood structural floor on open-web wood joists and a GWB ceiling below. This paper will investigate the possibility that room resonances influenced the IIC ratings of the several floor systems tested. These data will be compared with IIC data collected for the same floor construction with the GWB ceiling removed. The removal of the GWB ceiling increased the receiver room volume and exposed the glass fiber insulation to the receiver room, thus eliminating the control of the 100-Hz 1/3-octave band over the IIC rating.
Nondestructive structural evaluation of wood floor systems with a vibration technique.
Xiping Wang; Robert J. Ross; Lawrence Andrew Soltis
2002-01-01
The objective of this study was to determine if transverse vibration methods could be used to effectively assess the structural integrity of wood floors as component systems. A total of 10 wood floor systems, including 3 laboratory-built floor sections and 7 in-place floors in historic buildings, were tested. A forced vibration method was applied to the floor systems...
The test program measured the mold resistance of Lonseal Lonwood Natural flooring. One additional ancillary test for emissions of VOCs and formaldehyde was performed. Lonwood Natural flooring is a sheet vinyl product with an embossed wood-grain texture. Constructed in multiple la...
MTR BUILDING AND BALCONY FLOORS. CAMERA FACING EASTERLY. PHOTOGRAPHER DID ...
MTR BUILDING AND BALCONY FLOORS. CAMERA FACING EASTERLY. PHOTOGRAPHER DID NOT EXPLAIN DARK CLOUD. MTR WING WILL ATTACH TO GROUND FLOOR. INL NEGATIVE NO. 1567. Unknown Photographer, 2/28/1951 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Jin, Minfei; Wu, Yuelin; Wang, Jun; Ye, Weiping; Wang, Lei; Yin, Peipei; Liu, Wei; Pan, Chenhao; Hua, Xiaolin
2016-11-17
Pelvic floor dysfunction (PFD) is a condition affecting many women worldwide, with symptoms including stress urinary incontinence (SUI) and pelvic organ prolapse (POP). We have previously demonstrated stable elastin-expressing bone marrow-derived mesenchymal stem cells (BMSCs) attenuated PFD in rats, and aim to further study the effect of microRNA-29a-3p regulation on elastin expression and efficacy of BMSC transplantation therapy. We inhibited endogenous microRNA-29a-3p in BMSCs and investigated its effect on elastin expression by RT-PCR and Western blot. MicroRNA-29-inhibited BMSCs were then transplanted into PFD rats, accompanied by sustained release of bFGF using formulated bFGF in poly (lactic-co-glycolic acid) (PLGA) nanoparticles (NP), followed by evaluation of urodynamic tests. MicroRNA-29a-3p inhibition resulted in upregulated expression and secretion of elastin in in vitro culture of BMSCs. After co-injection with PLGA-loaded bFGF NP into the PFD rats in vivo, microRNA-29a-3p-inhibited BMSCs significantly improved the urodynamic test results. Our multidisciplinary study, combining microRNA biology, genetically engineered BMSCs, and nanoparticle technology, provides an excellent stem cell-based therapy for repairing connective tissues and treating PFD.
35. INTERIOR VIEW TO THE NORTHWEST OF ROOM 152, A ...
35. INTERIOR VIEW TO THE NORTHWEST OF ROOM 152, A FIRST FLOOR CORRIDOR AND VIEWING GALLERY ON THE WEST SIDE OF THE POST-MORTEM CELLS. VIEWING AND WORK STATIONS ARE IN THE EAST WALL. - Nevada Test Site, Reactor Maintenance Assembly & Dissassembly Facility, Area 25, Jackass Flats, Junction of Roads F & G, Mercury, Nye County, NV
STEEL BEAMS FOR FIRST FLOOR BEING READIED FOR CONCRETE POUR ...
STEEL BEAMS FOR FIRST FLOOR BEING READIED FOR CONCRETE POUR UNDER WEATHER SHELTER DURING COLD WINTER. NOTE ABUNDANCE OF BEAMS; THE FLOOR WILL SUPPORT HEAVY LOADS. INL NEGATIVE NO. 1175. Unknown Photographer, 12/20/1950 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
What Do You Really Know About Floor Finishes & Strippers?
ERIC Educational Resources Information Center
Wirth, T. J.
1972-01-01
An independent testing laboratory reveals the results of comparative studies done on vinyl flooring and the question of to wax or not to wax'' and which waxes work best with what flooring; and provides six evaluation tips on floor strippers. (EA)
Analytical modeling of transport aircraft crash scenarios to obtain floor pulses
NASA Technical Reports Server (NTRS)
Wittlin, G.; Lackey, D.
1983-01-01
The KRAS program was used to analyze transport aircraft candidate crash scenarios. Aircraft floor pulses and seat/occupant responses are presented. Results show that: (1) longitudinal only pulses can be represented by equivalent step inputs and/or static requirements; (2) the L1649 crash test floor longitudinal pulse for the aft direction (forward inertia) is less than 9g static or an equivalent 5g pulse; aft inertia accelerations are extremely small ((ch76) 3g) for representative crash scenarios; (3) a viable procedure to relate crash scenario floor pulses to standard laboratory dynamic and static test data using state of the art analysis and test procedures was demonstrated; and (4) floor pulse magnitudes are expected to be lower for wide body aircraft than for smaller narrow body aircraft.
MTRETR MAINTENANCE SHOP, TRA653. FLOOR PLAN FOR FIRST FLOOR: MACHINE ...
MTR-ETR MAINTENANCE SHOP, TRA-653. FLOOR PLAN FOR FIRST FLOOR: MACHINE SHOP, ELECTRICAL AND INSTRUMENT SHOP, TOOL CRIB, ELECTRONIC SHOP, LOCKER ROOM, SPECIAL TEMPERATURE CONTROLLED ROOM, AND OFFICES. "NEW" ON DRAWING REFERS TO REVISION OF 11/1956 DRAWING ON WHICH AREAS WERE DESIGNATED AS "FUTURE." HUMMEL HUMMEL & JONES 810-MTR-ETR-653-A-7, 5/1957. INL INDEX NO. 532-0653-00-381-101839, REV. 2. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Adappa, Nithin D; Sung, Chi-Kwang; Choi, Bryan; Huang, Tian-Gui; Genden, Eric M; Shin, Edward J
2008-09-01
To assess immune-based gene therapy in a murine floor of mouth (FOM) squamous cell carcinoma (SCC) model. In vitro and in vivo testing of immune therapy for SCC. Multiple SCC lines were infected by using advRSV-interleukin-12 (IL-12) and advCMV-interleukin-12/granulocyte macrophage colony-stimulating factor (IL-12/GM-CSF) and monitored for production of IL-12 and GM-CSF. Intratumoral injections of viral vectors were administered with systemic Ig-4-1BB ligand in an orthotopic murine FOM SCC model and followed for tumor size and survival. In vitro, all cell lines produced substantial levels of IL-12 and GM-CSF. In vivo, tumors treated with advCMV-IL-12/GM-CSF and Ig-4-1BBL showed a striking reduction in tumor volume (vs control P<0.0001) and improved median survival (38 days vs 19 days for control, P<0.0001). Combination immune-based therapies effectively improve survival in mice bearing FOM SCC over single-modality therapy.
Said, Hakim K; Bevers, Michael; Butler, Charles E
2007-12-01
Patients who undergo pelvic floor resection as treatment for recurrent cancer following radiation therapy have increased rates of complications, particularly if permanent prosthetic mesh is used for reconstruction. Human acellular dermal matrix (HADM), commonly used for reconstruction in other torso locations, is associated with lower rates of complications (including infection, adhesions and cutaneous exposure) than synthetic mesh. We describe an effective technique to reconstruct the pelvic floor and perineum with HADM and thigh-based flaps following pelvic exenteration and radical vulvectomy. A 75-year-old woman underwent radical resection of the pelvic floor and perineum to treat recurrent vulvar squamous cell carcinoma and osteoradionecrosis. The pelvic floor and perineal soft tissue defect were reconstructed with HADM (AlloDerm; LifeCell Corporation, Branchburg, NJ) and bilateral, thigh-based tissue flaps, respectively. Despite a large resection, previous irradiation therapy and bacterial contamination the wounds healed without complications. Reconstruction of pelvic floor defects using HADM is an option when wound conditions are unfavorable for the use of permanent prosthetic meshes.
Jin, Minfei; Chen, Ying; Zhou, Yun; Mei, Yan; Liu, Wei; Pan, Chenhao; Hua, Xiaolin
2016-04-05
Pelvic floor dysfunction (PFD) is a group of clinical conditions including stress urinary incontinence (SUI) and pelvic organ prolapse (POP). The abnormality of collagen and elastin metabolism in pelvic connective tissues is implicated in SUI and POP. To reconstitute the connective tissues with normal distribution of collagen and elastin, we transduced elastin to bone marrow-derived mesenchymal stem cells (BMSC). Elastin-expressing BMSCs were then differentiated to fibroblasts using bFGF, which produced collagen and elastin. To achieve the sustained release of bFGF, we formulated bFGF in poly (lactic-co-glycolic acid) (PLGA) nanoparticles (NP). In an in vitro cell culture system of 7 days, when no additional bFGF was administrated, the initial PLGA-loaded bFGF NP induced prolonged production of collagen and elastin from elastin-expressing BMSCs. In vivo, co-injection of PLGA-loaded bFGF NP and elastin-expressing BMSCs into the PFD rats significantly improved the outcome of urodynamic tests. Together, these results provided an efficient model of connective tissue engineering using BMSC and injectable PLGA-loaded growth factors. Our results provided the first instance of a multidisciplinary approach, combining both stem cell and nanoparticle technologies, for the treatment of PFD.
34. INTERIOR VIEW TO THE NORTH OF ROOMS 143 AND ...
34. INTERIOR VIEW TO THE NORTH OF ROOMS 143 AND 150, A FIRST FLOOR CORRIDOR AND VIEWING GALLERY ON THE EAST SIDE OF THE POST-MORTEM CELLS. VIEWING AND WORK STATIONS ARE IN THE NORTH AND WEST WALLS. - Nevada Test Site, Reactor Maintenance Assembly & Dissassembly Facility, Area 25, Jackass Flats, Junction of Roads F & G, Mercury, Nye County, NV
Neurophysiology of the pelvic floor in clinical practice: a systematic literature review
Bianchi, Francesca; Squintani, Giovanna Maddalena; Osio, Maurizio; Morini, Alberto; Bana, Cristina; Ardolino, Gianluca; Barbieri, Sergio; Bertolasi, Laura; Caramelli, Riccardo; Cogiamanian, Filippo; Currà, Antonio; de Scisciolo, Giuseppe; Foresti, Camillo; Frasca, Vittorio; Frasson, Emma; Inghilleri, Maurizio; Maderna, Luca; Motti, Luisa; Onesti, Emanuela; Romano, Marcello Calogero; Del Carro, Ubaldo
2017-01-01
Summary Neurophysiological testing of the pelvic floor is recognized as an essential tool to identify pathophysiological mechanisms of pelvic floor disorders, support clinical diagnosis, and aid in therapeutic decisions. Nevertheless, the diagnostic value of these tests in specific neurological diseases of the pelvic floor is not completely clarified. Seeking to fill this gap, the members of the Neurophysiology of the Pelvic Floor Study Group of the Italian Clinical Neurophysiology Society performed a systematic review of the literature to gather available evidence for and against the utility of neurophysiological tests. Our findings confirm the utility of some tests in specific clinical conditions [e.g. concentric needle electromyography, evaluation of sacral reflexes and of pudendal somatosensory evoked potentials (pSEPs) in cauda equina and conus medullaris lesions, and evaluation of pSEPs and perineal sympathetic skin response in spinal cord lesions], and support their use in clinical practice. Other tests, particularly those not currently supported by high-level evidence, when employed in individual patients, should be evaluated in the overall clinical context, or otherwise used for research purposes.
Generation of airborne Listeria innocua from model floor drains.
Berrang, Mark E; Frank, Joseph F
2012-07-01
Listeria monocytogenes can colonize floor drains in poultry processing and further processing facilities, remaining present even after cleaning and disinfection. Therefore, during wash down, workers exercise caution to avoid spraying hoses directly into drains in an effort to prevent the escape and transfer of drain microflora to food contact surfaces. The objective of this study was to examine the extent to which an inadvertent water spray into a colonized floor drain can cause the spread of airborne Listeria. Listeria innocua was used to inoculate a polyvinyl chloride model floor drain, resulting in approximately 10(8) cells per ml of phosphate-buffered saline and 10(4) attached cells per square centimeter of inner surface. Each model drain was subjected to a 2-s spray of tap water at 68.9 kPa from a distance of 1 m. Drains were sprayed while filled and again after emptying. Airborne cells were collected by using sedimentation plates containing Listeria selective agar which were placed on the floor and walls of a contained room at incremental horizontal and vertical distances of 0.6, 1.2, 2.4, or 4.0 m from the drain. Sedimentation plates were exposed for 10 min. A mechanical sampler was used to also collect air by impaction on the surface of Listeria selective agar to determine the number of cells per liter of air. The experiment was conducted in triplicate rooms for each of four replications. L. innocua was detected on sedimentation plates on the floor as far as 4.0 m from the drain and on walls as high as 2.4 m above the floor and 4 m from the drain. A 2-s spray with a water hose into a contaminated drain can cause airborne spread of Listeria, resulting in the potential for cross-contamination of food contact surfaces, equipment, and exposed product.
NASA Astrophysics Data System (ADS)
Zhou, Xuhong; Cao, Liang; Chen, Y. Frank; Liu, Jiepeng; Li, Jiang
2016-01-01
The developed pre-stressed cable reinforced concrete truss (PCT) floor system is a relatively new floor structure, which can be applied to various long-span structures such as buildings, stadiums, and bridges. Due to the lighter mass and longer span, floor vibration would be a serviceability concern problem for such systems. In this paper, field testing and theoretical analysis for the PCT floor system were conducted. Specifically, heel-drop impact and walking tests were performed on the PCT floor system to capture the dynamic properties including natural frequencies, mode shapes, damping ratios, and acceleration response. The PCT floor system was found to be a low frequency (<10 Hz) and low damping (damping ratio<2 percent) structural system. The comparison of the experimental results with the AISC's limiting values indicates that the investigated PCT system exhibits satisfactory vibration perceptibility, however. The analytical solution obtained from the weighted residual method agrees well with the experimental results and thus validates the proposed analytical expression. Sensitivity studies using the analytical solution were also conducted to investigate the vibration performance of the PCT floor system.
How Are Pelvic Floor Disorders Diagnosed?
... Share Facebook Twitter Pinterest Email Print How are pelvic floor disorders diagnosed? A physical exam may be all ... fee ). This test is used to evaluate the pelvic floor and rectum while the patient is having a ...
NASA Technical Reports Server (NTRS)
Arnold, D. B.; Burnside, J. V.; Hajari, J. V.
1976-01-01
Fire resistance mechanical property tests were conducted on sandwich configurations composed of resin-fiberglass laminates bonded with adhesives to Nomex honeycomb core. The test results were compared to proposed and current requirements for aircraft floor panel applications to demonstrate that the fire safety of the airplane could be improved without sacrificing mechanical performance of the aircraft floor panels.
76 FR 13580 - Bus Testing; Calculation of Average Passenger Weight and Test Vehicle Weight
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-14
... occupied per standing passenger from 1.5 to 1.75 square feet, and updating the Structural Strength and... standing passenger from 1.5 square feet of free floor space to 1.75 square feet of free floor space to... (assumed to be each 1.75 square foot of free floor space). * * * * * 3. Amend Appendix A to part 665 by...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-22
... Permit Floor Brokers To Use Personal Portable Phone Devices on The Trading Floor Due to the Unavailability of Exchange- Provided Cell Phones Beginning on October 10, 2013 Until the Earlier of When Cell Phone Service Is Restored or October 11, 2013 October 16, 2013. Pursuant to Section 19(b)(1) \\1\\ of the...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-22
... Not Permit Floor Brokers To Use Personal Portable Phone Devices on the Trading Floor Due to the Unavailability of Exchange-Provided Cell Phones Beginning on October 10, 2013 Until the Earlier of When Cell Phone Service Is Restored or October 11, 2013 October 16, 2013. Pursuant to Section 19(b)(1) \\1\\ of the...
Dairy cow preferences for soft or hard flooring when standing or walking.
Telezhenko, E; Lidfors, L; Bergsten, C
2007-08-01
Concrete is the most commonly used alley flooring in confined dairy herds because of its qualities of construction and ease of cleaning. Nevertheless, the hardness, abrasiveness, and slipperiness of concrete floors have adverse effects on animal well-being and health, and yielding rubber flooring is becoming popular as a way of improving the flooring conditions on walkways. The aim of this study was to investigate preferences of dairy cows for rubber compared with concrete flooring under the conditions of a commercial dairy farm. The study was conducted in an organic dairy herd with free-stall housing. Floor preference was tested on groups of standing cows in a 120-m2 holding pen before milking, and 1 yr later on a 12- x 3-m walkway. The holding pen and the walkway were divided lengthwise into 2 identical sections. Two types of solid rubber mats (soft and extra soft) were tested against solid concrete in the holding pen. Slatted and solid rubber mats were tested against slatted concrete in the walkway. Each floor type was tested over 4 d on the left side and 4 d on the right side of the holding pen and the walkway, respectively. Concrete flooring on both sides of the sections was tested as a control before the testing of different section materials. All observations of the distribution of cows in the sections were made from video recordings captured in association with the afternoon milking. The number of cows on each section was recorded approximately every 7 min in the holding pen, and continuously on the walkway. A significantly higher proportion of cows stood on the side with the soft and extra soft rubber mats (65.1 +/- 2.7 and 69.3 +/- 2.6%, respectively, mean +/- SEM) compared with the control distribution when only the solid concrete was available (50.9 +/- 3.9%). A significantly higher proportion of nonlame cows walked exclusively on the side with the slatted (64.5 +/- 5.4%, d 4) or solid rubber mats (68.2 +/- 5.1%, d 4) compared with controls (28.9 +/- 4.3%). Lame cows within a group of walking cows did not show a higher preference for soft flooring as distinct as nonlame cows (52.7 +/- 6.9 and 59.4 +/- 6.2% for the solid and slatted rubber mats, respectively, at d 4 vs. 40.3 +/- 6.2% for control), presumably because of competition with other, higher ranked cows. It was concluded that the majority of cows preferred to walk and stand on soft rubber rather than on concrete flooring.
Support design and practice for floor heave of deeply buried roadway
NASA Astrophysics Data System (ADS)
Liu, Chaoke; Ren, Jianxi; Gao, Bingli; Song, Yongjun
2017-05-01
Aiming at the severe floor heave of auxiliary haulage roadway in Jianzhuang Coal Mine, the paper analysed mechanical environment and failure characteristics of auxiliary haulage roadway surrounding rock with the combination of mechanical test, theoretical analysis, industrial test, etc. The mechanical mechanism for deformation and failure of weak rock roadway in Jianzhuang Coal Mine was disclosed by establishing a roadway mechanical model under the effect of even-distributed load, which provided a basis for the design of inverted concrete arch. Based on complex failure mechanism of the roadway, a support method with combined inverted concrete arch and anchor in floor was proposed. The result shows that the ground stress environment has extremely adverse influence on the roadway, and the practice indicates that the floor heave countermeasures can effectively control the floor heave. The obtained conclusion provides a reference for the research and design on control technology of roadway floor heave in the future.
LOFT, TAN650. Service building preamp tower, top three floors. Floor ...
LOFT, TAN-650. Service building pre-amp tower, top three floors. Floor plan, cable mazes, duct labyrinth. Borated water tank enclosure on roof. Kaiser engineers 6413-11-STEP/LOFT-650-A-3. Date: October 1964. INEEL index code no. 036-650-00-486-122215 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
NASA Technical Reports Server (NTRS)
Smith, Russell W.; Langford, William M.
2012-01-01
In support of NASA s Habitat Demonstration Unit - Deep Space Habitat Prototype, a number of evolved structural sections were designed, fabricated, analyzed and installed in the 5 meter diameter prototype. The hardware consisted of three principal structural sections, and included the development of novel fastener insert concepts. The articles developed consisted of: 1) 1/8th of the primary flooring section, 2) an inner radius floor beam support which interfaced with, and supported (1), 3) two upper hatch section prototypes, and 4) novel insert designs for mechanical fastener attachments. Advanced manufacturing approaches were utilized in the fabrication of the components. The structural components were developed using current commercial aircraft constructions as a baseline (for both the flooring components and their associated mechanical fastener inserts). The structural sections utilized honeycomb sandwich panels. The core section consisted of 1/8th inch cell size Nomex, at 9 lbs/cu ft, and which was 0.66 inches thick. The facesheets had 3 plys each, with a thickness of 0.010 inches per ply, made from woven E-glass with epoxy reinforcement. Analysis activities consisted of both analytical models, as well as initial closed form calculations. Testing was conducted to help verify analysis model inputs, as well as to facilitate correlation between testing and analysis. Test activities consisted of both 4 point bending tests as well as compressive core crush sequences. This paper presents an overview of this activity, and discusses issues encountered during the various phases of the applied research effort, and its relevance to future space based habitats.
Recent testing of a micro autonomous positioning system for multi-object instrumentation
NASA Astrophysics Data System (ADS)
Cochrane, W. A.; Atkinson, D. C.; Bailie, T. E. C.; Dickson, C.; Lim, T.; Luo, X.; Montgomery, D. M.; Schnetler, H.; Taylor, W. D.; Wilson, B.
2012-09-01
A multiple pick off mirror positioning sub-system has been developed as a solution for the deployment of mirrors within multi-object instrumentation such as the EAGLE instrument in the European Extremely Large Telescope (E-ELT). The positioning sub-system is a two wheeled differential steered friction drive robot with a footprint of approximately 20 x 20 mm. Controlled by RF communications there are two versions of the robot that exist. One is powered by a single cell lithium ion battery and the other utilises a power floor system. The robots use two brushless DC motors with 125:1 planetary gear heads for positioning in the coarse drive stages. A unique power floor allows the robots to be positioned at any location in any orientation on the focal plane. The design, linear repeatability tests, metrology and power continuity of the robot will be evaluated and presented in this paper. To gather photons from the objects of interest it is important to position POMs within a sphere of confusion of less than 10 μm, with an angular alignment better than 1 mrad. The robots potential of meeting these requirements will be described through the open-loop repeatability tests conducted with a Faro laser beam tracker. Tests have involved sending the robot step commands and automatically taking continuous measurements every three seconds. Currently the robot is capable of repeatedly travelling 233 mm within 0.307 mm at 5 mm/s. An analysis of the power floors reliability through the continuous monitoring of the voltage across the tracks with a Pico logger will also be presented.
Novel safety floors do not influence early compensatory balance reactions in older adults.
Wright, Alexander D; Heckman, George A; McIlroy, William E; Laing, Andrew C
2014-01-01
Novel safety flooring systems are a promising approach for reducing fall-related injuries in seniors, as they have been demonstrated to substantially reduce impact severity during falls, while minimally impairing balance control in community-dwelling older women. This pilot study aimed to characterize the potential effects of flooring conditions on dynamic balance control in retirement home-dwellers with more limited mobility. A tether-release paradigm was used to simulate a trip-type perturbation in 15 seniors across five flooring surfaces (three novel safety floors and one carpet compared to institutional-grade resilient rolled-sheeting). Kinetic and kinematic data tracked the displacement profiles of the underfoot centre-of-pressure and whole-body centre-of-mass, which were used to characterize compensatory balance reactions. Difference tests (ANOVA) found that the onset of the compensatory balance reaction was not associated with floor condition, nor were the timing and magnitude of peak centre-of-pressure excursion (minimum margin of safety) and velocity. Accordingly, the minimum margin of safety of the centre-of-mass was not significantly different across floors. Equivalence tests supported these findings. This study provides evidence that the carpet and novel safety floors tested do not negatively influence characteristics of initial dynamic balance responses following a lean-and-release perturbation compared to an institutional-grade resilient rolled-sheeting surface. In combination with reports of substantial force attenuative properties during fall-related impacts, these findings support the promise of novel safety floors as a biomechanically effective strategy for reducing fall-related injuries. Crown Copyright © 2014. Published by Elsevier B.V. All rights reserved.
ETR, TRA642. CONSOLE FLOOR. CAMERA IS ON WEST SIDE OF ...
ETR, TRA-642. CONSOLE FLOOR. CAMERA IS ON WEST SIDE OF FLOOR AND FACES NORTH. OUTER WALL OF STORAGE CANAL IS AT RIGHT. SHIELDING IS THICKER AT LOWER LEVEL, WHERE SPENT FUEL ELEMENTS WILL COOL AFTER REMOVAL FROM REACTOR. INL NEGATIVE NO. 56-1401. Jack L. Anderson, Photographer, 5/1/1956 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
2006-08-21
Dynamic Testing of In-Situ Composite Floors and Evaluation of Vibration Serviceability Using the Finite Element Method By Anthony R. Barrett...Setareh Alfred L. Wicks 21 August 2006 Blacksburg, VA Keywords: vibration, floor, serviceability , walking, modal analysis, fundamental frequency...burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Washington Headquarters Services
Operational Testing of Floor Cleaning Cloths for Household ...
Report The objective of this study was to evaluate the Swiffer® Sweeper® floor mop system (SSFMS) as a low-tech method to clean indoor residential floors contaminated with B. anthracis spores (the causative agent of anthrax).
NASA Astrophysics Data System (ADS)
Negreira, J.; Trollé, A.; Jarnerö, K.; Sjökvist, L.-G.; Bard, D.
2015-03-01
In timber housing constructions, vibrations can be a nuisance for inhabitants. Notably, the vibrational response of wooden floor systems is an issue in need of being dealt with more adequately in the designing of such buildings. Studies addressing human response to vibrations are needed in order to be able to better estimate what level of vibrations in dwellings can be seen as acceptable. In the present study, measurements on five different wooden floors were performed in a laboratory environment at two locations in Sweden (SP in Växjö and LU in Lund). Acceleration measurements were carried out while a person either was walking on a particular floor or was seated in a chair placed there as the test leader was walking on the floor. These participants filled out a questionnaire regarding their perception and experiencing of the vibrations in question. Independently of the subjective tests, several static and dynamic characteristics of the floors were determined through measurements. The ultimate aim was to develop indicators of human response to floor vibrations, specifically those regarding vibration acceptability and vibration annoyance, their being drawn based on relationships between the questionnaire responses obtained and the parameter values determined on the basis of the measurements carried out. To that end, use was made of multilevel regression. Although the sample of floors tested was small, certain clear trends could be noted. The first eigenfrequency (calculated in accordance with Eurocode 5) and Hu and Chui's criterion (calculated from measured quantities) proved to be the best indicators of vibration annoyance, and the Maximum Transient Vibration Value (computed on the basis of the accelerations experienced by the test subjects) to be the best indicator of vibration acceptability.
Smolen, Tomasz; Chuderski, Adam
2015-01-01
Fluid intelligence (Gf) is a crucial cognitive ability that involves abstract reasoning in order to solve novel problems. Recent research demonstrated that Gf strongly depends on the individual effectiveness of working memory (WM). We investigated a popular claim that if the storage capacity underlay the WM-Gf correlation, then such a correlation should increase with an increasing number of items or rules (load) in a Gf-test. As often no such link is observed, on that basis the storage-capacity account is rejected, and alternative accounts of Gf (e.g., related to executive control or processing speed) are proposed. Using both analytical inference and numerical simulations, we demonstrated that the load-dependent change in correlation is primarily a function of the amount of floor/ceiling effect for particular items. Thus, the item-wise WM correlation of a Gf-test depends on its overall difficulty, and the difficulty distribution across its items. When the early test items yield huge ceiling, but the late items do not approach floor, that correlation will increase throughout the test. If the early items locate themselves between ceiling and floor, but the late items approach floor, the respective correlation will decrease. For a hallmark Gf-test, the Raven-test, whose items span from ceiling to floor, the quadratic relationship is expected, and it was shown empirically using a large sample and two types of WMC tasks. In consequence, no changes in correlation due to varying WM/Gf load, or lack of them, can yield an argument for or against any theory of WM/Gf. Moreover, as the mathematical properties of the correlation formula make it relatively immune to ceiling/floor effects for overall moderate correlations, only minor changes (if any) in the WM-Gf correlation should be expected for many psychological tests.
ETR, TRA642 AND TRA647. FLOOR PLANS FOR FIRST AND SECOND ...
ETR, TRA-642 AND TRA-647. FLOOR PLANS FOR FIRST AND SECOND FLOORS OF THE OFFICE AND CONTROL BUILDING ALONG THE NORTH WALL OF THE ETR BUILDING. HEALTH PHYSICS, OPERATIONS, AND CONTROL ROOM. AIRLOCK DOOR. OFFICES. STAIRWAY LOCATIONS. KAISER ETR-5528-MTR-642-A-3, 10/1955. INL INDEX NO. 532-0642-00-100911, REV. 0. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
PROCESS WATER BUILDING, TRA605. FLOOR AND ROOF PLANS FOR SECOND ...
PROCESS WATER BUILDING, TRA-605. FLOOR AND ROOF PLANS FOR SECOND FLOOR. DETAILS OF CONCRETE ROOF SLABS. FLASH EVAPORATOR SUPPORTS AND PIPE OPENINGS TO TANKS BELOW. NOTE SPECIFIES THAT EQUIPMENT IS TO BE INSTALLED BEFORE ERECTION OF ROOF AND WALLS. BLAW-KNOX 3150-805-4, 1/1951. INL INDEX NO. 531-0605-62-098-100660, REV. 2. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
ETR BUILDING, TRA642, INTERIOR. CONSOLE FLOOR, NORTH HALF. CAMERA IS ...
ETR BUILDING, TRA-642, INTERIOR. CONSOLE FLOOR, NORTH HALF. CAMERA IS NEAR NORTHWEST CORNER AND FACING SOUTH ALONG WEST CORRIDOR. STORAGE CANAL IS ALONG LEFT OF VIEW; PERIMETER WALL, ALONG RIGHT. CORRIDOR WAS ONE MEANS OF WALKING FROM NORTH TO SOUTH SIDE OF CONSOLE FLOOR. INL NEGATIVE NO. HD46-18-1. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
View from second floor platform looking up at subsequent platforms. ...
View from second floor platform looking up at subsequent platforms. Note the Shuttle assembly outlined by the platform edges. - Marshall Space Flight Center, Saturn V Dynamic Test Facility, East Test Area, Huntsville, Madison County, AL
Floor Plans Level 15 Load Platform, Level 17 Lower ...
Floor Plans - Level 15 Load Platform, Level 17 Lower Platform, Level 22 and Upper Platform, and Level 27 - Marshall Space Flight Center, Saturn V S-IC Static Test Facility, West Test Area, Huntsville, Madison County, AL
Finite Element Analysis of an Energy Absorbing Sub-floor Structure
NASA Technical Reports Server (NTRS)
Moore, Scott C.
1995-01-01
As part of the Advanced General Aviation Transportation Experiments program, the National Aeronautics and Space Administration's Langley Research Center is conducting tests to design energy absorbing structures to improve occupant survivability in aircraft crashes. An effort is currently underway to design an Energy Absorbing (EA) sub-floor structure which will reduce occupant loads in an aircraft crash. However, a recent drop test of a fuselage specimen with a proposed EA sub-floor structure demonstrated that the effects of sectioning the fuselage on both the fuselage section's stiffness and the performance of the EA structure were not fully understood. Therefore, attempts are underway to model the proposed sub-floor structure on computers using the DYCAST finite element code to provide a better understanding of the structure's behavior in testing, and in an actual crash.
Need to Identify Parameters of Concrete in the Weakest Zone of the Industrial Floor
NASA Astrophysics Data System (ADS)
Stawiski, Bohdan; Radzik, Łukasz
2017-10-01
The ways in which industrial floors are exploited leads to the requirement for the highest strength of their upper zone. Physical phenomena occurring during the compaction and hardening of the concrete cause different strength distributions. In the top zone of industrial floors, the strength is significantly lower (over a dozen MPa) than the strength in the bottom zone (several dozen MPa). Standard tests of control samples do not detect this fact. Processes for the application and finishing of embedded mineral-aggregate hardeners (dry shakes) can be regarded as uncontrolled. The effects of the use of dry shakes are not evaluated. In combination with the phenomenon of bleeding, they often fail by delamination. This paper presents the results of industrial floor testing. The ultrasonic pulse velocity method with dry point contact transducers was used. The results show how upper layer strength was reduced, and how dry shakes application affected the strength of the floor. The strength distribution in hardened concrete, which delaminated from the rest of the floor was presented as well. The extension of compulsory control tests of concrete samples was proposed. In the authors’ opinion, particular attention should be paid to 3 centimetres of the upper layer.
EVAPORATOR FLOOR, CLARIFIERS TO THE LEFT, SCALES TO THE RIGHT, ...
EVAPORATOR FLOOR, CLARIFIERS TO THE LEFT, SCALES TO THE RIGHT, EVAPORATOR CELLS ONE, TWO AND THREE IN THE BACKGROUND. VIEW FROM NORTHWEST FROM LIME VATS - Lihue Plantation Company, Sugar Mill Building, Haleko Road, Lihue, Kauai County, HI
LOFT. Containment and service building (TAN650) ground floor plan. Penetrations ...
LOFT. Containment and service building (TAN-650) ground floor plan. Penetrations in dome wall. Shielded personnel maze at airlock door. Reactor chamber floor hatches and holddowns. Rails in concrete floor. Kaiser engineers 6413-11-STEP/LOFT-650-A-2. Date: October 1964. INEEL index code no. 036-650-00-486-122214 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
Distribution of Cryptococcus neoformans in a natural site.
Ruiz, A; Fromtling, R A; Bulmer, G S
1981-01-01
Pigeon droppings in a vacant tower were assayed for the number and size of viable cells of Cryptococcus neoformans. The dry, thinly scattered floor debris contained 2.6 x 10(6) viable cells per g--300 times more cells than were cultured from a large, compact pile of pigeon droppings (7.4 x 10(3) cells per g). Aerosols generated from floor debris containing pigeon droppings had an average of 360 viable cells in 31 liters of air; 27 of these cells (7.5%) were 1.1 to 3.3 micrometers in diameter and, therefore, capable of human lung deposition. Environmental factors which may influence the distribution, survival, and proliferation of C. neoformans in nature are discussed. PMID:7012011
Characterization of the protective capacity of flooring systems using force-deflection profiling.
Glinka, Michal N; Karakolis, Thomas; Callaghan, Jack P; Laing, Andrew C
2013-01-01
'Safety floors' aim to decrease the risk of fall-related injuries by absorbing impact energy during falls. Ironically, excessive floor deflection during walking or standing may increase fall risk. In this study we used a materials testing system to characterize the ability of a range of floors to absorb energy during simulated head and hip impacts while resisting deflection during simulated single-leg stance. We found that energy absorption for all safety floors (mean (SD)=14.8 (4.9)J) and bedside mats (25.1 (9.3)J) was 3.2- to 5.4-fold greater than the control condition (commercial carpet). While footfall deflections were not significantly different between safety floors (1.8 (0.7)mm) and the control carpet (3.7 (0.6)mm), they were significantly higher for two bedside mats. Finally, all of the safety floors, and two bedside mats, displayed 3-10 times the energy-absorption-to-deflection ratios observed for the baseline carpet. Overall, these results suggest that the safety floors we tested effectively addressed two competing demands required to reduce fall-related injury risk; namely the ability to absorb substantial impact energy without increasing footfall deflections. This study contributes to the literature suggesting that safety floors are a promising intervention for reducing fall-related injury risk in older adults. Copyright © 2012 IPEM. Published by Elsevier Ltd. All rights reserved.
Do stages of menopause affect the outcomes of pelvic floor muscle training?
Tosun, Özge Çeliker; Mutlu, Ebru Kaya; Tosun, Gökhan; Ergenoğlu, Ahmet Mete; Yeniel, Ahmet Özgur; Malkoç, Mehtap; Aşkar, Niyazi; İtil, İsmail Mete
2015-02-01
The purpose of our study is to determine whether there is a difference in pelvic floor muscle strength attributable to pelvic floor muscle training conducted during different stages of menopause. One hundred twenty-two women with stress urinary incontinence and mixed urinary incontinence were included in this prospective controlled study. The participants included in this study were separated into three groups according to the Stages of Reproductive Aging Workshop staging system as follows: group 1 (n = 41): stages -3 and -2; group 2 (n = 32): stages +1 and -1; and group 3 (n = 30): stage +2. All three groups were provided an individual home exercise program throughout the 12-week study. Pelvic floor muscle strength before and after the 12-week treatment was measured in all participants (using the PERFECT [power, endurance, number of repetitions, and number of fast (1-s) contractions; every contraction is timed] scheme, perineometry, transabdominal ultrasound, Brink scale, pad test, and stop test). Data were analyzed using analysis of variance. There were no statistically significant differences in pre-exercise training pelvic floor muscle strength parameters among the three groups. After 12 weeks, there were statistically significant increases in PERFECT scheme, Brink scale, perineometry, and ultrasound values. In contrast, there were significant decreases in stop test and 1-hour pad test values observed in the three groups (P = 0.001, dependent t test). In comparison with the other groups, group 1 demonstrated statistically significant improvements in the following postexercise training parameters: power, repetition, speed, Brink vertical displacement, and stop test. The lowest increase was observed in group 2 (P < 0.05). Strength increase can be achieved at all stages of menopause with pelvic floor muscle training, but the rates of increase vary according to the menopausal stage of the participants. Women in the late menopausal transition and early menopause are least responsive to pelvic floor muscle strength training. Further studies in this field are needed.
This data was generated from a small chamber bis(2-ethylhexyl) phthalate (DEHP) emission test. It was to participate an interaboratory study of DEHP emissions from vinyl flooring in a SVOC emission chamber organized by Virginia Polytechnic Institute and State University (VT).
NASA Technical Reports Server (NTRS)
Littell, Justin D. (Inventor)
2017-01-01
An energy-absorbing (EA) beam member and having a cell core structure is positioned in an aircraft fuselage proximate to the floor of the aircraft. The cell core structure has a length oriented along a width of the fuselage, a width oriented along a length of the fuselage, and a depth extending away from the floor. The cell core structure also includes cell walls that collectively define a repeating conusoidal pattern of alternating respective larger and smaller first and second radii along the length of the cell core structure. The cell walls slope away from a direction of flight of the aircraft at a calibrated lean angle. An EA beam member may include the cell core structure and first and second plates along the length of the cell core structure on opposite edges of the cell material.
PUMP HOUSE FOR MTR WELL NO. 1, TRA601. FLOOR PLAN, ...
PUMP HOUSE FOR MTR WELL NO. 1, TRA-601. FLOOR PLAN, ELEVATIONS, SECTION SHOWING WELL CASING, ROOF FRAMING PLAN. AS BUILT. WELL HOUSE FOR WELL NO. 2, TRA-602, WAS IDENTICAL IN ALL PARTICULARS EXCEPT FLOOR DIMENSIONS AND ARRANGEMENT OF PUMP AND ELECTRICAL EQUIPMENT INSIDE. IDAHO OPERATIONS OFFICE MTR-601-IDO-1, 12/1954. INL INDEX NO. 531-0601-00-396-110463, REV. 2. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Michael G. Shelton
1995-01-01
Five forest floor weights (0, 10, 20, 30, and 40 MgJha), three forest floor compositions (pine, pine-hardwood, and hardwood), and two seed placements (forest floor and soil surface) were tested in a three-factorial. split-plot design with four incomplete, randomized blocks. The experiment was conducted in a nursery setting and used wooden frames to define 0.145-m
LPT. Shield test facility (TAN645 and 646). Floor plan and ...
LPT. Shield test facility (TAN-645 and -646). Floor plan and room names. Ralph M. Parsons 1229-17 ANP/GE-6-645-A-1. April 1957. Approved by INEEL Classification Office for public release. INEEL index code no. 037-0645/0646-00-693-107347 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
Cariati, Paolo; Cabello Serrano, Almudena; Roman Ramos, Maria; Sanchez Lopez, Dario; Fernandez Solis, Jose; Martinez Lara, Ildefonso
2018-05-11
The main aim of the present report is to study the behavior of SCC of the floor of the mouth. A retrospective analysis was conducted using the records of patients diagnosed with squamous cell carcinoma of the floor of the mouth between 2000 and 2012 in the HUVN. Ninety-three patients with squamous cell carcinoma of the floor of the mouth treated with tumourectomy and selective neck dissection were included in the study. The pattern of distribution of cervical metastases and numerous histological features such as T-stage, N stage, surgical margins, tumor thickness, ECS (extracapsular spread) and vascular invasion were analyzed. Level I was the most affected level, followed by Level II. T stage, tumor thickness, and surgical margins showed a strong relationship with the risk of developing a local or cervical failure at follow-up. Overall survival was 52.7%. T stage, tumor thickness, N stage, recurrence, extracapsular spread, and vascular invasion were also associated with a poor prognosis. SCC of the floor of the mouth is an aggressive disease even at early stages. Due to the low rate of positive nodes observed at level IV and V in clinically N0 patients, supraomohyoid neck dissection might be considered sufficiently safe in this group. Copyright © 2018 Sociedad Española de Otorrinolaringología y Cirugía de Cabeza y Cuello. Publicado por Elsevier España, S.L.U. All rights reserved.
Foarde, Karin; Berry, Michael
2004-01-01
Choosing the appropriate floor surface for a school environment is a complex issue. To assist school personnel in determining which flooring is best for their school, we studied the biocontaminant levels associated with carpeted and hard surface flooring. Two schools were selected, one predominantly tiled and one predominantly carpeted, as similar as possible with the exception of their floor coverings. Neither school was a "problem" building. Multiple biocontaminants were measured. For flooring, there were statistically significant differences for all the tested biocontaminants except fungi. The carpeted surfaces, being strong sinks, generally had higher surface loadings of the biocontaminants, while the airborne levels were significantly higher over tiled floors. Significant differences in airborne levels were found for dust mass, spores, fungi, beta-1,3 glucans, and endotoxins. The results suggest that carpet flooring was not the major contributor to airborne levels of biocontaminants in these two nonproblem schools.
SAFETY AND SECURITY BUILDING, TRA614. SIMPLIFIED FLOOR LAYOUT AND WEST ...
SAFETY AND SECURITY BUILDING, TRA-614. SIMPLIFIED FLOOR LAYOUT AND WEST ELEVATION. BLAW-KNOX 3150-14-1, 1/1950. INL INDEX NO. 531-0614-00-098-100024, REV. 2. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
A&M. TAN607 floor plans. Shows three floor levels of pool, ...
A&M. TAN-607 floor plans. Shows three floor levels of pool, hot shop, and warm shop. Includes view of pool vestibule, personnel labyrinth, location of floor rails, and room numbers of office areas, labs, instrument rooms, and stairways. This drawing was re-drawn to show as-built features in 1993. Ralph M. Parsons 902-3-ANP-607-A 96. Date of original: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 034-0607-00-693-106748 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
Evaluation of Mobile Phone Interference With Aircraft GPS Navigation Systems
NASA Technical Reports Server (NTRS)
Pace, Scott; Oria, A. J.; Guckian, Paul; Nguyen, Truong X.
2004-01-01
This report compiles and analyzes tests that were conducted to measure cell phone spurious emissions in the Global Positioning System (GPS) radio frequency band that could affect the navigation system of an aircraft. The cell phone in question had, as reported to the FAA (Federal Aviation Administration), caused interference to several GPS receivers on-board a small single engine aircraft despite being compliant with data filed at the time with the FCC by the manufacturer. NASA (National Aeronautics and Space Administration) and industry tests show that while there is an emission in the 1575 MHz GPS band due to a specific combination of amplifier output impedance and load impedance that induces instability in the power amplifier, these spurious emissions (i.e., not the intentional transmit signal) are similar to those measured on non-intentionally transmitting devices such as, for example, laptop computers. Additional testing on a wide sample of different commercial cell phones did not result in any emission in the 1575 MHz GPS Band above the noise floor of the measurement receiver.
Effects of pelvic floor muscle training during pregnancy.
de Oliveira, Claudia; Lopes, Marco Antonio Borges; Carla Longo e Pereira, Luciana; Zugaib, Marcelo
2007-08-01
The objective of the present study was to evaluate the effect of pelvic floor muscle training in 46 nulliparous pregnant women. The women were divided into 2 groups: an exercise group and a control group. Functional evaluation of the pelvic floor muscle was performed by digital vaginal palpation using the strength scale described by Ortiz and by a perineometer (with and without biofeedback). The functional evaluation of the pelvic floor muscles showed a significant increase in pelvic floor muscle strength during pregnancy in both groups (P < .001). However, the magnitude of the change was greater in the exercise group than in the control group (47.4% vs. 17.3%, P < .001). The study also showed a significant positive correlation (Spearman's test, r = 0.643; P < .001) between perineometry and digital assessment in the strength of pelvic floor muscles. Pelvic floor muscle training resulted in a significant increase in pelvic floor muscle pressure and strength during pregnancy. A significant positive correlation between functional evaluation of the pelvic floor muscle and perineometry was observed during pregnancy.
Engine Research Building’s Central Control Room
1948-07-21
Operators in the Engine Research Building’s Central Control Room at the National Advisory Committee for Aeronautics (NACA) Lewis Flight Propulsion Laboratory. The massive 4.25-acre Engine Research Building contains dozens of test cells, test stands, and altitude chambers. A powerful collection of compressors and exhausters located in the central portion of the basement provided process air and exhaust for these test areas. This system is connected to similar process air systems in the laboratory’s other large test facilities. The Central Control Room coordinates this activity and communicates with the local utilities. This photograph was taken just after a major upgrade to the control room in 1948. The panels on the wall contain rudimentary floor plans of the different Engine Research Building sections with indicator lights and instrumentation for each test cell. The process air equipment included 12 exhausters, four compressors, a refrigeration system, cooling water, and an exhaust system. The operators in the control room kept in contact with engineers running the process air system and those conducting the tests in the test cells. The operators also coordinated with the local power companies to make sure enough electricity was available to operate the powerful compressors and exhausters.
Cervical lymph node metastases in squamous cell carcinoma of tongue and floor of mouth.
Ehsan-ul-Haq, Muhammad; Warraich, Riaz Ahmed; Abid, Hina; Sajid, Malik Ali Hassan
2011-01-01
Oral squamous cell carcinoma has high chances of cervical lymph node metastasis. This case series describes the distribution of cervical lymph nodes in 50 cases of squamous cell carcinoma of tongue and floor of mouth. The mean age was 47.28±10.5 years. Thirty positive metastatic lymph nodes were found; 90% occurring at level I-II mostly in T4 size but also in T1 and T2 cases. The distribution of involved lymph nodes in oral cancer affects the neck dissection extent and is, therefore, an important pre-operative feature.
Lachance, Chantelle C; Korall, Alexandra M B; Russell, Colin M; Feldman, Fabio; Robinovitch, Stephen N; Mackey, Dawn C
2016-09-01
The aim of this study was to investigate the effects of flooring type and resident weight on external hand forces required to push floor-based lifts in long-term care (LTC). Novel compliant flooring is designed to reduce fall-related injuries among LTC residents but may increase forces required for staff to perform pushing tasks. A motorized lift may offset the effect of flooring on push forces. Fourteen female LTC staff performed straight-line pushes with two floor-based lifts (conventional, motor driven) loaded with passengers of average and 90th-percentile resident weights over four flooring systems (concrete+vinyl, compliant+vinyl, concrete+carpet, compliant+carpet). Initial and sustained push forces were measured by a handlebar-mounted triaxial load cell and compared to participant-specific tolerance limits. Participants rated pushing difficulty. Novel compliant flooring increased initial and sustained push forces and subjective ratings compared to concrete flooring. Compared to the conventional lift, the motor-driven lift substantially reduced initial and sustained push forces and perceived difficulty of pushing for all four floors and both resident weights. Participants exerted forces above published tolerance limits only when using the conventional lift on the carpet conditions (concrete+carpet, compliant+carpet). With the motor-driven lift only, resident weight did not affect push forces. Novel compliant flooring increased linear push forces generated by LTC staff using floor-based lifts, but forces did not exceed tolerance limits when pushing over compliant+vinyl. The motor-driven lift substantially reduced push forces compared to the conventional lift. Results may help to address risk of work-related musculoskeletal injury, especially in locations with novel compliant flooring. © 2016, Human Factors and Ergonomics Society.
8. "TEST STAND, ARCHITECTURAL, FLOOR PLANS AND SCHEDULES." Specifications No. ...
8. "TEST STAND, ARCHITECTURAL, FLOOR PLANS AND SCHEDULES." Specifications No. ENG-04-353-55-72; Drawing No. 60-0912; sheet 22 of 148; file no. 1320/73. Stamped: RECORD DRAWING - AS CONSTRUCTED. Below stamp: Contract no. 4338, no change. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-A Terminal Room, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA
16 CFR 1211.7 - Inherent entrapment protection requirements.
Code of Federal Regulations, 2010 CFR
2010-01-01
... door a minimum of 2 inches (50.8 mm). (b)(1) A solid object is to be placed on the floor of the test... the operator. When tested on the floor, the object shall be 1 inch (25.4 mm) high. In the test... when the door is fully closed. (2) For operators other than those attached to the door, a solid object...
Materials emission of chemicals--PVC flooring materials.
Lundgren, B; Jonsson, B; Ek-Olausson, B
1999-09-01
Data of chemical emissions from flooring materials have been collected and investigated in a database known as METS. The emission tests are performed using the Field and Laboratory Emission Cell (FLEC). The emission rates of total volatile organic compounds (TVOC) in the boiling point range of hexane to octadecane varies from around 4,000 micrograms/(m2.h) to less than 10 micrograms/(m2.h). Results obtained 1994/95 are presented and compared with the results obtained in 1992 for similar materials. The tests are performed 4 weeks and 26 weeks after the manufacturing of the material. The emission rates of TVOC decrease on the average approximately 60% from 4 to 26 weeks. The differences and trends in emission rates of individual chemicals and their use are discussed. For many VOCs emission rates decrease rapidly and become near to or below 2 micrograms/(m2.h) (the detection limit) after 26 weeks. For a small number of individual compounds the emission rate decrease little over 26 weeks. A small number of chemicals are singled out for particular interest in a health and comfort evaluation based on the emission results.
ETR BUILDING, TRA642, INTERIOR. CONSOLE FLOOR, SOUTH HALF. CABLE TUNNEL. ...
ETR BUILDING, TRA-642, INTERIOR. CONSOLE FLOOR, SOUTH HALF. CABLE TUNNEL. CAMERA FACING SOUTH INTO ETR ELECTRICAL BUILDING (TRA-648). INL NEGATIVE NO. HD46-20-2. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
MODELING OF THE FAST ORGANIC EMISSIONS FROM A WOOD-FINISHING PRODUCT -- FLOOR WAX
The paper discusses environmental chamber and full-scale residential house tests conducted to characterize the fast organic emissions from a wood finishing product, floor wax. For the environmental chamber tests, a very small amount (< 5 g/sq m) of the wax was applied to an alumi...
20. FIFTH FLOOR BLDG. 28A, VIEW SOUND TEST ROOMS LOOKING ...
20. FIFTH FLOOR BLDG. 28A, VIEW SOUND TEST ROOMS LOOKING NORTHEAST. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT
22. FIFTH FLOOR BLDG. 28A, DETAIL DOUBLE DOORS SOUND TEST ...
22. FIFTH FLOOR BLDG. 28A, DETAIL DOUBLE DOORS SOUND TEST ROOM LOOKING NORTH. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT
21. FIFTH FLOOR BLDG. 28A, ELEVATION WEST END SOUND TEST ...
21. FIFTH FLOOR BLDG. 28A, ELEVATION WEST END SOUND TEST ROOM. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT
The Shock and Vibration Bulletin. Part 3. Skylab, Vibration Testing and Analysis
1973-06-01
Zft- ,Instrument Unit - (Acoustic Test Only) -orward Compartment Crew Ouarters Meteoroid Shield IntertageTACS Spheres (Acoustic Tesi - Radiator...weighs more than the lower floor. You Mru ertes: You hadn’t flown this struc- might feel that since the analysis approach wasconfirmed on the upper floor
ETR, TRA642. BENCH MARK AND ELEVATION LOCATIONS, FLOOR LOADING DATA, ...
ETR, TRA-642. BENCH MARK AND ELEVATION LOCATIONS, FLOOR LOADING DATA, CRANE WORKING AREAS. PHILLIPS PETROLEUM COMPANY ETR-D-1584, 5/1959. INL INDEX NO. 532-0642-00-706-020323, REV. 3. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Li, Huaqiong; Fang, Crystal Hay Yu; Shi, Wenxiong; Gurusamy, Subramaniam; Li, Shuzhou; Krishnan, Manoj N; George, Saji
2015-11-04
Although building constructions are a recurring part of urbanization, the health risk of particulate matters (PM) originating from such activities have seldom been subjected to detailed studies. We sought to characterize the relative risk of air borne PM collected from different heights (ground and top floor) of a building adjacent to a building under early phase of construction. We determined the physico-chemical properties such as size and shape, elemental composition and surface charge of the PM. The oxidative stress dependent cytotoxic and pro-inflammatory responses were assessed in BEAS-2B and RAW 264.7 cell lines using high-content-screening platforms. In comparison to top floor, the total mass of PM collected from ground floor was two-three folds higher and the mass fraction was dominated by PM20-35. Elemental analysis showed abundance of Si, Al, K, Ca and Fe in bigger PM while for PM0.25-0.5 it was mostly constituted by C and crystals rich in S and K. PM caused NFκB activation, secretion of pro-inflammatory cytokines and cytotoxicity wherein PM0.25-0.5 was the most potent among the tested PM. Estimated exposure level and lung burden together with the data on hazard potential were used for developing a MATLAB based risk-assessment model which suggested that the potential for health risk is relatively higher at the ground floor. Our studies demonstrated differences in, relative abundance of PM, their physicochemical and biological properties collected from different heights adjacent to a construction site and showed that relative health risk is higher at the ground floor. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Zhu, Leina; Gonzalez, Jorge
2017-01-01
Researchers and practitioners often use standardized vocabulary tests such as the Peabody Picture Vocabulary Test-4 (PPVT-4; Dunn and Dunn, 2007) and its companion, the Expressive Vocabulary Test-2 (EVT-2; Williams, 2007), to assess English vocabulary skills as an indicator of children's school readiness. Despite their psychometric excellence in the norm sample, issues arise when standardized vocabulary tests are used to asses children from culturally, linguistically and ethnically diverse backgrounds (e.g., Spanish-speaking English language learners) or delayed in some manner. One of the biggest challenges is establishing the appropriateness of these measures with non-English or non-standard English speaking children as often they score one to two standard deviations below expected levels (e.g., Lonigan et al., 2013). This study re-examines the issues in analyzing the PPVT-4 and EVT-2 scores in a sample of 4-to-5-year-old low SES Hispanic preschool children who were part of a larger randomized clinical trial on the effects of a supplemental English shared-reading vocabulary curriculum (Pollard-Durodola et al., 2016). It was found that data exhibited strong floor effects and the presence of floor effects made it difficult to differentiate the invention group and the control group on their vocabulary growth in the intervention. A simulation study is then presented under the multilevel structural equation modeling (MSEM) framework and results revealed that in regular multilevel data analysis, ignoring floor effects in the outcome variables led to biased results in parameter estimates, standard error estimates, and significance tests. Our findings suggest caution in analyzing and interpreting scores of ethnically and culturally diverse children on standardized vocabulary tests (e.g., floor effects). It is recommended appropriate analytical methods that take into account floor effects in outcome variables should be considered.
An experimental parametric study of VOC from flooring systems exposed to alkaline solutions.
Sjöberg, A; Ramnäs, O
2007-12-01
This study outlined the influence of a number of parameters affecting the emission rate from one of the largest sources of VOC in the building stock in the Nordic countries. This source is flooring systems of polyvinyl chloride or linoleum attached to a substrate of moisture damaged or insufficiently dried concrete. The secondary emission rate of degradation products was measured, with the Field and Laboratory Emission Cell, on different flooring systems consisting of three different floorings and three adhesives, exposed to three different aqueous solutions in the range of 11-13.1 pH. The conclusion drawn in this study is that the great majority of the secondary emission originates from the floor adhesive. The occurrence of adhesive and the amount of adhesive used have a significant influence on the emission rate. A critical pH value for degradation of the adhesive seems to lie somewhere between 11 and 13 pH. When designing a floor system or a renovation of a damaged flooring system, it is important to bear in mind the influence of parameters that may drastically shorten the service life. Flooring adhesive may decompose in a moist alkaline environment and give rise to unacceptable secondary emission rates.
FIRST FLOOR PLAN OF REMOTE ANALYTICAL FACILITY (CPP627) SHOWING REMOTE ...
FIRST FLOOR PLAN OF REMOTE ANALYTICAL FACILITY (CPP-627) SHOWING REMOTE ANALYTICAL LABORATORY, DECONTAMINATION ROOM, AND MULTICURIE CELL ROOM. INL DRAWING NUMBER 200-0627-00-008-105065. ALTERNATE ID NUMBER 4272-14-102. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
Bhan, Shivam; Levine, Iris; Laing, Andrew C
2013-12-01
The biomechanical effectiveness of safety floors has never been assessed during sideways falls with human volunteers. Furthermore, the influence of body mass index (BMI) and gender on the protective capacity of safety floors is unknown. The purpose of this study was to test whether safety floors provide greater impact attenuation compared with traditional flooring, and whether BMI and gender modify their impact attenuation properties. Thirty participants (7 men and 7 women of low BMI; 7 men and 9 women of high BMI) underwent lateral pelvis release trials on 2 common floors and 4 safety floors. As a group, the safety floors reduced peak force (by up to 11.7%), and increased the time to peak force (by up to 25.5%) compared with a traditional institutional grade floor. Force attenuation was significantly higher for the low BMI group, and for males. Force attenuation was greatest for the low BMI males, averaging 26.5% (SD = 3.0) across the safety floors. These findings demonstrate an overall protective effect of safety floors during lateral falls on the pelvis, but also suggest augmented benefits for frail older adults (often with low body mass) who are at an increased risk of hip fracture.
Deflection of Resilient Materials for Reduction of Floor Impact Sound
Lee, Jung-Yoon; Kim, Jong-Mun
2014-01-01
Recently, many residents living in apartment buildings in Korea have been bothered by noise coming from the houses above. In order to reduce noise pollution, communities are increasingly imposing bylaws, including the limitation of floor impact sound, minimum thickness of floors, and floor soundproofing solutions. This research effort focused specifically on the deflection of resilient materials in the floor sound insulation systems of apartment houses. The experimental program involved conducting twenty-seven material tests and ten sound insulation floating concrete floor specimens. Two main parameters were considered in the experimental investigation: the seven types of resilient materials and the location of the loading point. The structural behavior of sound insulation floor floating was predicted using the Winkler method. The experimental and analytical results indicated that the cracking strength of the floating concrete floor significantly increased with increasing the tangent modulus of resilient material. The deflection of the floating concrete floor loaded at the side of the specimen was much greater than that of the floating concrete floor loaded at the center of the specimen. The Winkler model considering the effect of modulus of resilient materials was able to accurately predict the cracking strength of the floating concrete floor. PMID:25574491
Deflection of resilient materials for reduction of floor impact sound.
Lee, Jung-Yoon; Kim, Jong-Mun
2014-01-01
Recently, many residents living in apartment buildings in Korea have been bothered by noise coming from the houses above. In order to reduce noise pollution, communities are increasingly imposing bylaws, including the limitation of floor impact sound, minimum thickness of floors, and floor soundproofing solutions. This research effort focused specifically on the deflection of resilient materials in the floor sound insulation systems of apartment houses. The experimental program involved conducting twenty-seven material tests and ten sound insulation floating concrete floor specimens. Two main parameters were considered in the experimental investigation: the seven types of resilient materials and the location of the loading point. The structural behavior of sound insulation floor floating was predicted using the Winkler method. The experimental and analytical results indicated that the cracking strength of the floating concrete floor significantly increased with increasing the tangent modulus of resilient material. The deflection of the floating concrete floor loaded at the side of the specimen was much greater than that of the floating concrete floor loaded at the center of the specimen. The Winkler model considering the effect of modulus of resilient materials was able to accurately predict the cracking strength of the floating concrete floor.
Global rates of marine sulfate reduction and implications for sub-sea-floor metabolic activities
NASA Astrophysics Data System (ADS)
Bowles, Marshall W.; Mogollón, José M.; Kasten, Sabine; Zabel, Matthias; Hinrichs, Kai-Uwe
2014-05-01
Sulfate reduction is a globally important redox process in marine sediments, yet global rates are poorly quantified. We developed an artificial neural network trained with 199 sulfate profiles, constrained with geomorphological and geochemical maps to estimate global sulfate-reduction rate distributions. Globally, 11.3 teramoles of sulfate are reduced yearly (~15% of previous estimates), accounting for the oxidation of 12 to 29% of the organic carbon flux to the sea floor. Combined with global cell distributions in marine sediments, these results indicate a strong contrast in sub-sea-floor prokaryote habitats: In continental margins, global cell numbers in sulfate-depleted sediment exceed those in the overlying sulfate-bearing sediment by one order of magnitude, whereas in the abyss, most life occurs in oxic and/or sulfate-reducing sediments.
Nuclear changes in oral mucosa of alcoholics and crack cocaine users.
Webber, L P; Pellicioli, A C A; Magnusson, A S; Danilevicz, C K; Bueno, C C; Sant'Ana Filho, M; Rados, P V; Carrard, V C
2016-02-01
The effects of drugs of abuse on oral mucosa are only partly understood. The aims of the present study were to: (1) evaluate the frequency of nuclear changes in normal-appearing oral mucosa of alcoholics and crack cocaine users and (2) assess their association with cell proliferation rate. Oral smears were obtained from the border of the tongue and floor of the mouth of 26 crack cocaine users (24 males and 2 females), 29 alcoholics (17 males and 12 females), and 35 controls (17 males and 18 females). Histological slides were submitted to Feulgen staining to assess the frequency of micronuclei (MN), binucleated cells (BN), broken eggs (BE), and karyorrhexis (KR). A significant increase in the frequency of MN was observed in cells exfoliated from the tongue of crack cocaine users (p = 0.01), and alcoholics showed a higher frequency of KR in cells obtained from the floor of the mouth (p = 0.01). Our findings suggest that the use of crack cocaine induces clastogenic effects, whereas alcoholism is associated with higher degrees of keratinization in the floor of the mouth. © The Author(s) 2015.
THERMAL EVALUATION OF CONTAMINATED LIQUID ONTO CELL FLOORS
DOE Office of Scientific and Technical Information (OSTI.GOV)
NOEMAIL), J
2009-05-04
For the Salt Disposition Integration Project (SDIP), postulated events in the new Salt Waste Processing Facility (SWPF) can result in spilling liquids that contain Cs-137 and organics onto cell floors. The parameters of concern are the maximum temperature of the fluid following a spill and the time required for the maximum fluid temperature to be reached. Control volume models of the various process cells have been developed using standard conduction and natural convection relationships. The calculations are performed using the Mathcad modeling software. The results are being used in Consolidated Hazards Analysis Planning (CHAP) to determine the controls that maymore » be needed to mitigate the potential impact of liquids containing Cs-137 and flammable organics that spill onto cell floors. Model development techniques and the ease of making model changes within the Mathcad environment are discussed. The results indicate that certain fluid spills result in overheating of the fluid, but the times to reach steady-state are several hundred hours. The long times allow time for spill clean up without the use of expensive mitigation controls.« less
A&M. TAN607 floor plan for first floor. Shows stepped door ...
A&M. TAN-607 floor plan for first floor. Shows stepped door plug design from hot shop into special services cubicle, cubicle windows, and other details. This drawing was re-drawn to show as-built conditions in 1985. Ralph M. Parsons 902-3-ANP-607-A 99. Date of original: January 1955. Approved by INEEL Classification Office for public release. INEEL index code no. 034-0607-00-693-106751 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
Gustavsson, Johanna; Bonander, Carl; Andersson, Ragnar; Nilson, Finn
2015-10-01
Fall-related injuries affect the lives of elderly to a substantial degree. This quasi-experimental study investigates the fall-injury reducing effect of impact absorbing flooring among female nursing home residents. The intervention site is a nursing home in Sweden where impact absorbing flooring was installed in parts of one of six wards (six out of 10 apartments (excluding bathrooms), the communal dining-room and parts of the corridor). The impact absorbing flooring is a 12 mm thick closed cell flexible polyurethane/polyurea composite tile (500×500 mm) with an exterior surface of polyurethane/polyurea. A generalised linear model (log-binomial) was used to calculate the RR of injury from falls on impact absorbing flooring compared to falls on regular flooring, adjusted for age, body mass index, visual and cognitive impairments. During the study period (1 October 2011 to 31 March 2014), 254 falls occurred on regular flooring and 77 falls on impact absorbing flooring. The injury/fall rate was 30.3% for falls on regular flooring and 16.9% for falls on impact absorbing flooring. Adjusted for covariates, the impact absorbing flooring significantly reduced the RR of injury in the event of a fall by 59% (RR 0.41 (95% Cl 0.20 to 0.80)). This is, to our knowledge, the first study evaluating the injury-reducing effect of impact absorbing flooring in a nursing home showing statistically significant effect. The results from this study are promising, indicating the considerable potential of impact absorbing flooring as a fall-related injury intervention among frail elderly. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
LPT. Shield test facility (TAN646). Floor plan for water treatment ...
LPT. Shield test facility (TAN-646). Floor plan for water treatment room on west facade, tank and filter locations in basement along service tunnel and in coupling station. Ralph M. Parsons 1229-17 ANP/GE-6-646-P-2. April 1957. INEEL Index code no. 037-0645/0646-51-693-107387 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
DOE Office of Scientific and Technical Information (OSTI.GOV)
Josephson, Walter S.
The 324 Building on the Hanford site played a key role in radiochemical and metallurgical research programs conducted by DOE. The B hot cell in the 324 Building was the site of high-level waste vitrification research. During clean-out operations in November 2009, a tear was noted in the stainless steel liner on the floor of B Cell. Exposure rate readings taken at various locations in the soil about 0.5 meters below B Cell reached 8,900 Roentgen (R) per hour, confirming the existence of a significant soil contamination field. The source of the radioactive material was likely a 510 L spillmore » from the Canister Fabrication Project, consisting of purified, concentrated Cs-137 and Sr-90 solutions totaling 48,000 TBq (1.3 MCi). MCNP modeling was used to estimate that the measured exposure rates were caused by 5,900 TBq (160 kCi) of Sr- 90 and Cs-137, although additional contamination was thought to exist deeper in the soil column. Two physical soil samples were obtained at different depths, which helped verify the contamination estimates. A detailed exposure rate survey inside B Cell was combined with additional MCNP modeling to estimate that an additional 1,700 TBq (460 kCi) is present just below the floor. Based on the results of the sampling campaign, it is likely that the radioactive material below B Cell is primarily consists of feed solutions from the FRG Canister Fabrication Project, and that it contains purified Sr-90 and Cs-137 with enough actinide carryover to make some of the soil transuranic. The close agreement between the Geoprobe calculations and the physical samples adds confidence that there are more than 3700 TBq (100,000 Ci) of Sr-90 and Cs-137 in the soil approximately 1 meter below the cell floor. The majority of the Cs-137 is contained in the first meter of soil, while significant Sr-90 contamination extends to 10 meters below the cell floor. It is also likely that an additional 15,000 TBq (400,000 Ci) of Cs-137 and Sr-90 activity is present directly below the floor of the cell, and that the residual activity inside the cell is only half of the previous estimates. However, the partitioning of activity between residuals in the cell and in the soil below the floor is much more uncertain than the activity calculations associated with the Geoprobe measurements. Taken together, the calculated soil activities represent about half of the spill associated with the FRG Canister Fabrication project. The remainder of the spill is believed to have remained in the cell, where the majority has been removed as part of cell cleanup activities. The magnitude of the soil contamination below 324 B Cell is sobering, and it represents one of the most challenging remediation activities in the DOE complex. Of course, safe remediation begins with a good understanding of the magnitude of the problem. As a result, additional modeling and cross-comparison efforts are planned for 2012. (authors)« less
NASA Astrophysics Data System (ADS)
Cao, Liang; Liu, Jiepeng; Li, Jiang; Zhang, Ruizhi
2018-04-01
An extensive experimental and theoretical research study was undertaken to study the vibration serviceability of a long-span prestressed concrete floor system to be used in the lounge of a major airport. Specifically, jumping impact tests were carried out to obtain the floor's modal parameters, followed by an analysis of the distribution of peak accelerations. Running tests were also performed to capture the acceleration responses. The prestressed concrete floor was found to have a low fundamental natural frequency (≈ 8.86 Hz) corresponding to the average modal damping ratio of ≈ 2.17%. A coefficients β rp is proposed for convenient calculation of the maximum root-mean-square acceleration for running. In the theoretical analysis, the prestressed concrete floor under running excitation is treated as a two-span continuous anisotropic rectangular plate with simply-supported edges. The calculated analytical results (natural frequencies and root-mean-square acceleration) agree well with the experimental ones. The analytical approach is thus validated.
PROCESS WATER BUILDING, TRA605, INTERIOR. FIRST FLOOR. ELECTRICAL EQUIPMENT IN ...
PROCESS WATER BUILDING, TRA-605, INTERIOR. FIRST FLOOR. ELECTRICAL EQUIPMENT IN LEFT HALF OF VIEW. CAMERA IS IN NORTHWEST CORNER FACING SOUTHEAST. INL NEGATIVE NO. HD46-27-1. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
ETR BUILDING, TRA642, INTERIOR. FIRST FLOOR. INSIDE UTILITY CORRIDOR ALONG ...
ETR BUILDING, TRA-642, INTERIOR. FIRST FLOOR. INSIDE UTILITY CORRIDOR ALONG SOUTH PERIMETER WALL (COMMON TO ELECTRICAL BUILDING, TRA-648). CAMERA FACES WEST. INL NEGATIVE NO. HD46-16-2. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
SAFETY AND SECURITY BUILDING, TRA614. FLOOR, ROOF, AND FOUNDATION PLANS. ...
SAFETY AND SECURITY BUILDING, TRA-614. FLOOR, ROOF, AND FOUNDATION PLANS. ROOM FUNCTIONS. DOOR AND ROOM FINISH SCHEDULE. BLAW-KNOX 3150-814-1, 3/1950. INL INDEX NO. 531-0614-00-098-100702, REV. 6. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
MTR WING A, TRA604, INTERIOR. MAIN FLOOR. DETAIL VIEW INSIDE ...
MTR WING A, TRA-604, INTERIOR. MAIN FLOOR. DETAIL VIEW INSIDE LABORATORY 114. CAMERA FACING NORTH. DISPOSAL OF RADIOACTIVE MATERIALS IS UNDERWAY. INL NEGATIVE NO. HD46-12-4. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Floor Plans Engine Removal Platform, Hold Down Arm Platform, ...
Floor Plans - Engine Removal Platform, Hold Down Arm Platform, Hydraulic Equipment Platforms, Isometric Cutaway of Engine Removal Platform, Isometric Cutaway of Hold Down Arm Platform, Isometric Cutaway of Hydraulic Platforms and Engine Support System Access - Marshall Space Flight Center, Saturn V S-IC Static Test Facility, West Test Area, Huntsville, Madison County, AL
ETR BUILDING, TRA642, INTERIOR. CONSOLE FLOOR, SOUTH HALF. SOUTH SIDE ...
ETR BUILDING, TRA-642, INTERIOR. CONSOLE FLOOR, SOUTH HALF. SOUTH SIDE OF ETR REACTOR, CAMERA FACING NORTH. CABINET CONTAINING "NUCLEAR INSTRUMENT SYSTEMS" IS RESTRICTED. INL NEGATIVE NO. HD46-18-4. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Subjective assessments of floor slipperiness before and after walk under two lighting conditions.
Li, Kai Way; Zhao, Caijun; Peng, Lu; Liu, Ai-Qun
2018-06-01
A gait experiment was performed. The participants were tested under shoes, floors, surface and lighting conditions. They gave floor slipperiness ratings before and after a gait trial. The perceived sense of slip (PSOS) was collected. It was found that the perceived floor slipperiness (PFS) before walking was affected significantly by the lighting, floor and surface conditions. Relative low PFS values were recorded under wet and detergent-contaminated conditions in the normal daylight condition as compared with those in the dimmed condition. The PFS after the gait was significantly affected by the floor and surface conditions. The PSOS was highly correlated with the PFS after trial. The regression analyses results indicated that both the coefficient of friction (COF) of the floor and lighting were primary predictors of the PFS before a gait. The COF and walking speed were the primary predictors of the PFS after a gait.
Friction between footwear and floor covered with solid particles under dry and wet conditions.
Li, Kai Way; Meng, Fanxing; Zhang, Wei
2014-01-01
Solid particles on the floor, both dry and wet, are common but their effects on the friction on the floor were seldom discussed in the literature. In this study, friction measurements were conducted to test the effects of particle size of solid contaminants on the friction coefficient on the floor under footwear, floor, and surface conditions. The results supported the hypothesis that particle size of solids affected the friction coefficient and the effects depended on footwear, floor, and surface conditions. On dry surfaces, solid particles resulted in friction loss when the Neolite footwear pad was used. On the other hand, solid particles provided additional friction when measured with the ethylene vinyl acetate (EVA) footwear pad. On wet surfaces, introducing solid particles made the floors more slip-resistant and such effects depended on particle size. This study provides information for better understanding of the mechanism of slipping when solid contaminants are present.
Hopper, Luke S; Wheeler, Talia J; Webster, James M; Allen, Nick; Roberts, Jonathan R; Fleming, Paul R
2014-01-01
The mechanical properties of dance floors have the potential to influence dancers' performance and injury risk. Little information is available that describes dancers' preferences for dance floor mechanical properties. Investigation of dancers' perceptions of varied dance floors can serve to enlighten governing bodies, floor manufacturers, and the dance community. The aim of this study was to assess the perceptions of dancers from a touring professional ballet company regarding four floors with varied force reduction (FR) that were created to replicate those used by the company in normal dance training and performance. A specialized questionnaire was developed that incorporated a series of qualitative and quantitative measures that could be used by participants to express their perceptions of the custom built dance floors. Floor FR was quantified with reference to the protocols specified by European standards. Dancer perceptions were in general agreement with floor FR values; however, some discrepancies were observed. Dancers expressed a preference for floor FR within the mid to upper limits (57% to 72%) of the European standards, although a minority preferred low FR (approximately 36%) floors. A limited ability to perceive inconsistencies in FR across test floors was observed, which may have implications for injury risk. Investigation of the perceptions of dancers from more diverse backgrounds, on floors that provide a closer representation of typical dance studio and stage sizes, over longer periods of time, would provide further insight into the perceptual and adaptive responses of dancers to varied floor mechanical properties.
Jarungroongruangchai, Weerawut; Charoenpitakchai, Mongkol; Silpeeyodom, Tawatchai; Pruksapong, Chatchai; Burusapat, Chairat
2014-02-01
Squamous cell carcinoma (SCC) of the oral tongue and floor of mouth are the most common head and neck cancers. Regional metastasis of SCC is most likely found at the cervical lymph node. Size and characteristics of pathologically suspicious lymph nodes are related to the aggressiveness of the primary tumor: The objective of this study is to analyze the conrrelation between sizes of cervical node and metastasis in SCC of oral tongue and floor of mouth. Retrospective review was conducted firom the patient's charts between January 2008 and December 2012. Clinical, histopathology and surgical records were reviewed. Cervical lymph nodes ofSCC of oral tongue and floor of mouth were reviewed and divided into four groups depending on their size (1-5 mm, 6-9 mm, 10-30 mm and more than 30 am,). A p-value <0.05 was considered statistically significant. 196 patients with SCC of the oral cavity were recorded. Sixteen patients ofSCC of the oral tongue and 15patients of SCC of the floor of mouth underwent neck dissection (641 cervical nodes). Most ofthe patients were diagnosed with stage 3 (41.94%). Extracapsular extension was found in 72.15% of SCC of oral tongue and 73.33 % of SCC ofthe floor of mouth. Size of cervical lymph nodes less than 10 mm was found to be metastasis at 9.27% and 10.82% of SCC of oral tongue and floor of mouth, respectively. Cervical node metastasis can be found in SCC of the oral tongue and floor ofmouth with clinlically negative node andsize of cervical node less than 10 mm. Here in, size of cervical node less than 10 mm was still important due to the chance for metastasis especially high grade tumors, advanced stage cancer and lymphovascular invasion.
Buttner, Mark P.; Cruz, Patricia; Stetzenbach, Linda D.; Cronin, Tracy
2007-01-01
This research was designed to evaluate surface sampling protocols for use with culture and quantitative PCR (QPCR) amplification assay for detection of the gram-negative bacterial biothreat simulant Erwinia herbicola on a variety of surface materials. Surfaces selected for evaluation were wood laminate, glass and computer monitor screens, metal file cabinets, plastic arena seats, nylon seat cushions, finished concrete flooring, and vinyl tile flooring. Laboratory and test chamber studies were performed to evaluate two sampling methods, a sponge and a macrofoam swab, for detection of E. herbicola on surface materials. In laboratory trials, seven materials were inoculated with a known concentration of E. herbicola cells and samples were collected from the surfaces of the materials to determine sampling efficiencies. Culture analysis was ineffective for assessing E. herbicola collection efficiency because very few culturable cells were obtained from surface samples. QPCR demonstrated that E. herbicola DNA was present in high concentrations on all of the surface samples, and sampling efficiencies ranged from 0.7 to 52.2%, depending on the sampling method and the surface material. The swab was generally more efficient than the sponge for collection of E. herbicola from surfaces. Test chamber trials were also performed in which E. herbicola was aerosolized into the chamber and allowed to settle onto test materials. Surface sampling results supported those obtained in laboratory trials. The results of this study demonstrate the capabilities of QPCR to enhance the detection and enumeration of biocontaminants on surface materials and provide information on the comparability of sampling methods. PMID:17416685
Buttner, Mark P; Cruz, Patricia; Stetzenbach, Linda D; Cronin, Tracy
2007-06-01
This research was designed to evaluate surface sampling protocols for use with culture and quantitative PCR (QPCR) amplification assay for detection of the gram-negative bacterial biothreat simulant Erwinia herbicola on a variety of surface materials. Surfaces selected for evaluation were wood laminate, glass and computer monitor screens, metal file cabinets, plastic arena seats, nylon seat cushions, finished concrete flooring, and vinyl tile flooring. Laboratory and test chamber studies were performed to evaluate two sampling methods, a sponge and a macrofoam swab, for detection of E. herbicola on surface materials. In laboratory trials, seven materials were inoculated with a known concentration of E. herbicola cells and samples were collected from the surfaces of the materials to determine sampling efficiencies. Culture analysis was ineffective for assessing E. herbicola collection efficiency because very few culturable cells were obtained from surface samples. QPCR demonstrated that E. herbicola DNA was present in high concentrations on all of the surface samples, and sampling efficiencies ranged from 0.7 to 52.2%, depending on the sampling method and the surface material. The swab was generally more efficient than the sponge for collection of E. herbicola from surfaces. Test chamber trials were also performed in which E. herbicola was aerosolized into the chamber and allowed to settle onto test materials. Surface sampling results supported those obtained in laboratory trials. The results of this study demonstrate the capabilities of QPCR to enhance the detection and enumeration of biocontaminants on surface materials and provide information on the comparability of sampling methods.
FLOOR PLAN OF MAIN PROCESSING BUILDING (CPP601) BASEMENT SHOWING PROCESS ...
FLOOR PLAN OF MAIN PROCESSING BUILDING (CPP-601) BASEMENT SHOWING PROCESS CORRIDOR AND EIGHTEEN CELLS. TO LEFT IS LABORATORY BUILDING (CPP-602). INL DRAWING NUMBER 200-0601-00-706-051981. ALTERNATE ID NUMBER CPP-E-1981. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
SECOND FLOOR PLAN OF REMOTE ANALYTICAL FACILITY (CPP627) WARM LABORATORY ...
SECOND FLOOR PLAN OF REMOTE ANALYTICAL FACILITY (CPP-627) WARM LABORATORY ROOM, DECONTAMINATION ROOM, HOT CHEMISTRY LABORATORY, AND MULTICURIE CELL ROOM. INL DRAWING NUMBER 200-0627-00-098-105066. ALTERNATE ID NUMBER 4272-14-103. - Idaho National Engineering Laboratory, Idaho Chemical Processing Plant, Fuel Reprocessing Complex, Scoville, Butte County, ID
Ulm, Christian; Bertl, Kristina; Strbac, Georg D; Esfandeyari, Azadeh; Stavropoulos, Andreas; Zechner, Werner
2017-12-01
Sinus floor augmentation is a routinely used surgical technique for increasing the bone height/volume of the atrophic posterior maxilla. Optimal integration of the implanted augmentation material within the newly formed bone will-at least partly-depend on adequate vascularization to ensure sufficient recruitment of osteoblast and osteoclast precursor cells. The present technical note describes a modification intended to facilitate increased blood inflow into the augmented space. After preparation of the lateral window and elevation of the Schneiderian membrane, the cortical bone of the sinus floor is perforated several times either by using a piezoelectric device or a microsurgical handpiece with the corresponding tip or bur; these perforations should extend into the trabecular bone. The experiences with this modified technique after 12 patients are presented and discussed. It is expected that by means of this relatively simple technique, increased blood and cell inflow into the augmented space is achieved. This may, in turn, enhance new bone formation and improve the integration of the augmentation material.
TRITIUM LABORATORY, TRA666, INTERIOR. MAIN FLOOR. CONTROL ROOM ENCLOSURE AT ...
TRITIUM LABORATORY, TRA-666, INTERIOR. MAIN FLOOR. CONTROL ROOM ENCLOSURE AT CENTER OF VIEW. SIGN ABOVE DOOR SAYS "HYDRAULIC TEST FACILITY CONTROL ROOM." SIGN IN WINDOW SAYS "EATING AREA." "EVACUATION AND EMERGENCY INFORMATION" IS POSTED ON CABINET AT LEFT OF VIEW. INL NEGATIVE NO. HD30-2-3. Mike Crane, Photographer, 6/2001 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
NASA Technical Reports Server (NTRS)
Pope, L. D.; Wilby, E. G.; Willis, C. M.; Mayes, W. H.
1983-01-01
As part of the continuing development of an aircraft interior noise prediction model, in which a discrete modal representation and power flow analysis are used, theoretical results are considered for inclusion of sidewall trim, stiffened structures, and cabin acoustics with floor partition. For validation purposes, predictions of the noise reductions for three test articles (a bare ring-stringer stiffened cylinder, an unstiffened cylinder with floor and insulation, and a ring-stringer stiffened cylinder with floor and sidewall trim) are compared with measurements.
Krebs, N; Berry, S L; Tucker, C B
2011-01-01
Interest in the use of rubber flooring in freestall barns has increased, but little is known about which design features of these surfaces are important for cattle. In 2 experiments, we evaluated how the type and compressibility of the flooring surface in front of the feed bunk influenced the behavioral response to 4 h of forced standing after morning milking. Two flooring types were compared: rubber and concrete. Rubber was tested at 3 levels of compressibility: 2, 4, and 35 times as compressible as concrete. Four hours of forced standing was evaluated because it mimicked conditions that can occur on dairies, particularly when waiting for artificial insemination or veterinary treatment. The effects of cow weight and hoof surface area, gait score, and hoof health on the response to treatment were evaluated. Restless behavior, as measured by number of steps, almost doubled over the 4h of forced standing, regardless of flooring material. Cows lay down, on average, within 5 min after access to the lying area was provided. These results indicate that the 4 h of forced standing was uncomfortable. No differences in restless behavior were observed in association with the type or compressibility of the flooring surface in front of the feed bunk. Cow size, hoof health, or gait score did not consistently explain the response to the flooring treatments or stepping rate, although these populations of animals were generally healthy. It is unclear if comfort did not differ between the flooring options tested during 4 h of forced standing or if alterative methodology, such as measuring more subtle shifts in weight, is required to assess design features of rubber flooring. Copyright © 2011 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
The Effects of Inflated Seating Cushions on Engagement in Preschool Circle Time
ERIC Educational Resources Information Center
Seifert, Anna M.; Metz, Alexia E.
2017-01-01
Inflatable balls and cushions made of non-latex rubber can provide alternatives to sitting on the floor/ground or classroom chairs. This study tested the effect of inflatable cushions (wiggle cushions) placed on the floor for seating during circle time in typical preschool classrooms. The effect on attention was tested using alternating periods of…
MTR WING, TRA604. BASEMENT FLOOR PLAN. FIREPROOF RECORD ROOM BELOW ...
MTR WING, TRA-604. BASEMENT FLOOR PLAN. FIRE-PROOF RECORD ROOM BELOW COUNTING ROOM. HEATING AND COOLING EQUIPMENT. UNSPECIFIED EXPANSION AREA ALONG WEST WALL. BLAW-KNOX 3150-4-1, 7/1950. INL INDEX NO. 531-0604-00-098-100007, REV. 1. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
ETR, TRA642. ON GROUND FLOOR. WITH OUTER THERMAL RING IN ...
ETR, TRA-642. ON GROUND FLOOR. WITH OUTER THERMAL RING IN PLACE AND CONDUIT PRESERVED, HIGH-DENSITY CONCRETE IS PLACED BETWEEN THE THERMAL RING AND THE OUTER REACTOR FORM. INL NEGATIVE NO. 56-2400. Jack L. Anderson, Photographer, 6/10/1956 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Floor Plans Fuel Tank Support, Fuel Platform, and LOX ...
Floor Plans - Fuel Tank Support, Fuel Platform, and LOX Platform Plans - Marshall Space Flight Center, F-1 Engine Static Test Stand, On Route 565 between Huntsville and Decatur, Huntsville, Madison County, AL
Floor Plans Rolling Platform, Tech Systems Platform, and Load ...
Floor Plans - Rolling Platform, Tech Systems Platform, and Load Platform Plans - Marshall Space Flight Center, F-1 Engine Static Test Stand, On Route 565 between Huntsville and Decatur, Huntsville, Madison County, AL
Floor Plans Foundation Plan at Bedrock and Subgrade Level ...
Floor Plans - Foundation Plan at Bedrock and Subgrade Level Plan - Marshall Space Flight Center, F-1 Engine Static Test Stand, On Route 565 between Huntsville and Decatur, Huntsville, Madison County, AL
The distribution of mercury in a forest floor transect across the central United States
Charles H. (Hobie) Perry; Michael C. Amacher; William Cannon; Randall K. Kolka; Laurel Woodruff
2009-01-01
Mercury (Hg) stored in soil organic matter may be released when the forest floor is consumed by fire. Our objective is to document the spatial distribution of forest floor Hg for a transect crossing the central United States. Samples collected by the Forest Service, U.S. Department of Agriculture's Forest Inventory and Analysis Soil Quality Indicator were tested...
VIEW OF THE PRODUCTION FLOOR OF BUILDING 460. BUILDING 460 ...
VIEW OF THE PRODUCTION FLOOR OF BUILDING 460. BUILDING 460 WAS CONSTRUCTED FOR THE MANUFACTURE OF STAINLESS STEEL COMPONENTS SUCH AS RESERVOIRS, TUBES, AND NON-FISSILE TRIGGER COMPONENTS. MANUFACTURING, TESTING, AND INSPECTION PROCESSES OCCUPIED MOST OF THE GROUND FLOOR. (2/20/96) - Rocky Flats Plant, Stainless Steel & Non-Nuclear Components Manufacturing, Southeast corner of intersection of Cottonwood & Third Avenues, Golden, Jefferson County, CO
Berrang, Mark E; Hofacre, Charles L; Frank, Joseph F
2014-12-01
Listeria monocytogenes can colonize a poultry processing plant as a resident in floor drains. Limiting growth and attachment to drain surfaces may help lessen the potential for cross-contamination of product. The objective of this study was to compare a hydrogen peroxide-peroxyacetic acid-based chemical to chitosan-arginine or heat to prevent attachment of or destroy existing L. monocytogenes on the inner surface of model floor drains. L. monocytogenes was introduced to result in about 10(9) planktonic and attached cells within untreated polyvinyl chloride model drain pipes. Treatments (0.13 % peroxide-based sanitizer, 0.1 % chitosan-arginine, or 15 s of hot water at 95 to 100°C) were applied immediately after inoculation or after 24 h of incubation. Following treatment, all pipes were incubated for an additional 24 h; planktonic and attached cells were enumerated by plate count. All treatments significantly (P < 0.05) lowered numbers of planktonic and attached cells recovered. Chitosan-arginine resulted in approximately a 6-log reduction in planktonic cells when applied prior to incubation and a 3-log reduction after the inoculum had a chance to grow. Both heat and peroxide significantly outperformed chitosan-arginine (8- to 9-log reduction) and were equally effective before and after incubation. Heat was the only treatment that eliminated planktonic L. monocytogenes. All treatments were less effective against attached cells. Chitosan-arginine provided about a 4.5-log decrease in attached cells when applied before incubation and no significant decrease when applied after growth. Like with planktonic cells, peroxide-peroxyacetic acid and heat were equally effective before or after incubation, causing decreases ranging from 7 to 8.5 log for attached L. monocytogenes. Applied at the most efficacious time, any of these techniques may lessen the potential for L. monocytogenes to remain as a long-term resident in processing plant floor drains.
Study of Semi-Span Model Testing Techniques
NASA Technical Reports Server (NTRS)
Gatlin, Gregory M.; McGhee, Robert J.
1996-01-01
An investigation has been conducted in the NASA Langley 14- by 22-Foot Subsonic Tunnel in order to further the development of semi-span testing capabilities. A twin engine, energy efficient transport (EET) model with a four-element wing in a takeoff configuration was used for this investigation. Initially a full span configuration was tested and force and moment data, wing and fuselage surface pressure data, and fuselage boundary layer measurements were obtained as a baseline data set. The semi-span configurations were then mounted on the wind tunnel floor, and the effects of fuselage standoff height and shape as well as the effects of the tunnel floor boundary layer height were investigated. The effectiveness of tangential blowing at the standoff/floor juncture as an active boundary-layer control technique was also studied. Results indicate that the semi-span configuration was more sensitive to variations in standoff height than to variations in floor boundary layer height. A standoff height equivalent to 30 percent of the fuselage radius resulted in better correlation with full span data than no standoff or the larger standoff configurations investigated. Undercut standoff leading edges or the use of tangential blowing in the standoff/ floor juncture improved correlation of semi-span data with full span data in the region of maximum lift coefficient.
Wei, John T; Dunn, Rodney; Nygaard, Ingrid; Burgio, Kathryn; Lukacz, Emily S; Markland, Alayne; Wren, Patricia A; Brubaker, Linda; Barber, Matthew D; Jelovsek, J Eric; Spino, Cathie; Meikle, Susie; Janz, Nancy
To establish validity for the Pelvic Floor Disorders Network (PFDN) self-administered Adaptive Behavior Index (ABI) and to assess whether ABI assesses known discordance between severity of pelvic floor symptoms and self-reported bother. In addition to the ABI questionnaire, participants in 1 of 6 Pelvic Floor Disorders Network trials completed condition-specific measures of pretreatment symptom severity (including Pelvic Floor Distress Inventory; PFDI) and health-related quality of life (Pelvic Floor Impact Questionnaire; PFIQ). The final survey was developed from an iterative process using subject and expert endorsement, factor analyses, and response distributions. Domains were created using a development cohort (n = 304 women), reliability and validity were established using a validation cohort (n = 596 women), and test-retest reliability was assessed (n = 111 women). Factor analyses supported an 11-item avoidance domain and a 6-item hygiene domain. Cronbach' alphas were 0.88 and 0.68, respectively. Test-retest reliability was 0.84 for both domains. Construct validity was demonstrated in correlations between the ABI domains and baseline PFDI and PFIQ (r values, 0.43-0.79 with all P values <0.0001). Moreover, the ABI accounted for 8% to 26% of unexplained variance between the symptoms severity measure and the impact on health related quality of life. After treatment, avoidance domain scores improved for urinary and fecal incontinence groups and hygiene scores improved for the fecal incontinence group. The ABI is a reliable and valid measure in women with pelvic floor disorders. Adaptive behaviors account in part for discordance between pelvic floor symptom severity and bother.
NASA Technical Reports Server (NTRS)
Anderson, R. A.; Ougland, R. M.; Karch, R. J.
1978-01-01
Extensive fire resistance and mechanical property tests were conducted on sandwich configurations composed of resin-fiberglass laminates bonded with adhesive to Nomex honeycomb and foam core. The test results were used to select a combination of materials that would improve the fire safety of the airplane without sacrificing mechanical performance of the aircraft floor panels. A test panel is being service evaluated in a commercial aircraft.
42 CFR 84.151 - Harness test; minimum requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... concrete floor without disarranging the harness or exerting a pull on the facepiece. (5) The arrangement... manner that prevents a pull equivalent to dragging the maximum length of the hose over a concrete floor...
Yazgi, H; Uyanik, M H; Ayyildiz, A
2009-01-01
This study investigated the colonization of slime-producing coagulase-negative Staphylococcus (CoNS) in 80 patient wards in Turkey (40 vinyl and 40 ceramic tile floors). A total of 480 samples that included 557 CoNS isolates were obtained. Slime production was investigated with the Christensen method and methicillin-susceptibility was tested by the disk-diffusion method. There was a significant difference in the percentage of slime-producing CoNS isolates on vinyl (12.4%) versus ceramic tile flooring (4.4%). From vinyl flooring, the percentage of slime producing methicillin-resistant CoNS (MRCoNS) (8.9%) was significantly higher than for methicillin-sensitive CoNS (MSCoNS) (3.6%), whereas there was no difference from ceramic tile flooring (2.5% MRCoNS versus 1.8% MSCoNS). The most commonly isolated slime-producing CoNS species was S. epidermidis on both types of flooring. It is concluded that vinyl flooring seems to be a more suitable colonization surface for slime-producing CoNS than ceramic tile floors. Further studies are needed to investigate bacterial strains colonized on flooring materials, which are potential pathogens for nosocomial infections.
NASA Technical Reports Server (NTRS)
Theobald, M. A.
1978-01-01
The single source location used for helicopter model studies was utilized in a study to determine the distances and directions upstream of the model accurate at which measurements of the direct acoustic field could be obtained. The method used was to measure the decrease of sound pressure levels with distance from a noise source and thereby determine the Hall radius as a function of frequency and direction. Test arrangements and procedures are described. Graphs show the normalized sound pressure level versus distance curves for the glass fiber floor treatment and for the foam floor treatment.
ETRCF, TRA654, INTERIOR. CAMERA IS ON MAIN FLOOR. NOTE CRANE ...
ETR-CF, TRA-654, INTERIOR. CAMERA IS ON MAIN FLOOR. NOTE CRANE HOOKS. ELECTRICAL EQUIPMENT IS PART OF PAST EXPERIMENT. DOOR AT LEFT EDGE OF VIEW LEADS TO REACTOR SERVICE BUILDING, TRA-635. INL NEGATIVE NO. HD24-1-2. Mike Crane, Photographer, ca. 2003 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
ETR BUILDING, TRA642, INTERIOR. FIRST FLOOR. REACTOR IS IN CENTER ...
ETR BUILDING, TRA-642, INTERIOR. FIRST FLOOR. REACTOR IS IN CENTER OF VIEW. CAMERA FACES NORTHWEST. NOTE CRANE RAILS AND DANGLING ELECTRICAL CABLE AT UPPER PART OF VIEW FOR "MOFFETT 2 TON" CRANE. INL NEGATIVE NO. HD46-14-4. Mike Crane, Photographer, 2/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
ETR, TRA642. ON BASEMENT FLOOR. REACTOR VESSEL WILL BE PLACED ...
ETR, TRA-642. ON BASEMENT FLOOR. REACTOR VESSEL WILL BE PLACED WITHIN THE INNER METAL FORM. WHEN CONCRETE IS POURED OUTSIDE THIS FORM, CONDUIT HOLES WILL BE PRESERVE SPACE THROUGH HOLES. INL NEGATIVE NO. 56-1507. Jack L. Anderson, Photographer, 5/8/1956 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
MTR WING, TRA604. FIRST FLOOR PLAN. ENTRY LOBBY, MACHINE SHOP, ...
MTR WING, TRA-604. FIRST FLOOR PLAN. ENTRY LOBBY, MACHINE SHOP, INSTRUMENT SHOP, COUNTING ROOM, HEALTH PHYSICS LAB, LABS AND OFFICES, STORAGE, SHIPPING AND RECEIVING. BLAW-KNOX 3150-4-2, 7/1950. INL INDEX NO. 053-604-00-099-100008, REV. 7. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
MTRETR MAINTENANCE SHOP, TRA653. FLOOR PLAN FOR MEZZANINE: LUNCH AND ...
MTR-ETR MAINTENANCE SHOP, TRA-653. FLOOR PLAN FOR MEZZANINE: LUNCH AND CONFERENCE ROOM, STORAGE AREA, OFFICES FOR FOREMEN, STENOS, ENGINEERS, DISPATCHER, WOMEN'S RESTROOM. HUMMEL HUMMEL & JONES 810-MTR-ETR-653-A-12, 2/1958. INL INDEX NO. 532-0653-00-381-102837, REV. 3. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
FAST CHOPPER DETECTOR HOUSE, TRA665. SECOND FLOOR ADDITION: PLAN, SECTIONS ...
FAST CHOPPER DETECTOR HOUSE, TRA-665. SECOND FLOOR ADDITION: PLAN, SECTIONS AND DETAILS AS ADDED TO THE EXISTING CHOPPER HOUSE IN 1962. F.C. TORKELSON 842-MTR-665-S-3, 4/1962. INL INDEX NO. 531-0665-60-851-150997, REV. 3. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Piezoelectric energy harvester under parquet floor
NASA Astrophysics Data System (ADS)
Bischur, E.; Schwesinger, N.
2011-03-01
The design, fabrication and testing of piezoelectric energy harvesting modules for floors is described. These modules are used beneath a parquet floor to harvest the energy of people walking over it. The harvesting modules consist of monoaxial stretched PVDF-foils. Multilayer modules are built up as roller-type capacitors. The fabrication process of the harvesting modules is simple and very suitable for mass production. Due to the use of organic polymers, the modules are characterized by a great flexibility and the possibility to create them in almost any geometrical size. The energy yield was determined depending on the dynamic loading force, the thickness of piezoelectric active material, the size of the piezoelectric modules, their alignment in the walking direction and their position on the floor. An increase of the energy yield at higher loading forces and higher thicknesses of the modules was observed. It was possible to generate up to 2.1mWs of electric energy with dynamic loads of 70kg using a specific module design. Furthermore a test floor was assembled to determine the influence of the size, alignment and position of the modules on the energy yield.
Emission of volatile organic compounds (VOCs) from PVC floor coverings.
Wiglusz, R; Igielska, B; Sitko, E; Nikel, G; Jarnuszkiewicz, I
1998-01-01
In this study 29 PVC floor coverings were tested for emission of vinyl chloride (VC) and other volatile organic compounds (VOCs). A study on the effect of higher temperature on emission of VOCs from newly manufactured PVC flooring was also carried out. The study was conducted in climatic chamber, according to Polish Standard PN-89/Z-04021. GC method was used for analyzing of the compounds emitted. VC was not emitted from any of the floorings tested. Other VOCs were emitted in different concentrations. The influence of temperature on emission was conducted at temperatures of 23 degrees C and 35 degrees C from 2 hrs up to 180 days after introduction of materials in the chamber. The increase of temperature caused increase of total volatile organic compounds (TVOC) emission during 24 hrs of experiment. Then the emission was comparable for both temperatures. After 9 days emission of identified and unidentified compounds (TVOC) showed a rapid decay and stayed on very low level during a few months. The study conducted showed that PVC floorings after 10 days of installation in the room should not be source of indoor air contamination.
Yanfei Guo; Michael G. Shelton; B.R. Lockhart
1999-01-01
Effects of the forest floor (0, 10, 20, 30,40, and 50 Mg/ha) and acorn placement (buried 1.5 cm below the soil surface, pressed into the soil surface, and placed within the forest floor) on establishment and early development of water oak (Quercus nigra L.) seedlings were tested in a 6 x 3 factorial study in southeastern Arkansas. Increasing...
16. VIEW OF FIRST FLOOR EAST OPERATING GALLERY. NOTE THE ...
16. VIEW OF FIRST FLOOR EAST OPERATING GALLERY. NOTE THE SERIES OF MANIPULATOR ARMS ALONG THE LEFT WALL. - Nevada Test Site, Engine Maintenance Assembly & Disassembly Facility, Area 25, Jackass Flats, Mercury, Nye County, NV
NASA Technical Reports Server (NTRS)
Pope, L. D.; Wilby, E. G.
1982-01-01
An airplane interior noise prediction model is developed to determine the important parameters associated with sound transmission into the interiors of airplanes, and to identify apropriate noise control methods. Models for stiffened structures, and cabin acoustics with floor partition are developed. Validation studies are undertaken using three test articles: a ring stringer stiffened cylinder, an unstiffened cylinder with floor partition, and ring stringer stiffened cylinder with floor partition and sidewall trim. The noise reductions of the three test articles are computed using the heoretical models and compared to measured values. A statistical analysis of the comparison data indicates that there is no bias in the predictions although a substantial random error exists so that a discrepancy of more than five or six dB can be expected for about one out of three predictions.
Dual-stiffness flooring: can it reduce fracture rates associated with falls?
Knoefel, Frank; Patrick, Louise; Taylor, Jodie; Goubran, Rafik
2013-04-01
Falls cause significant morbidity and mortality in long term care facilities. Dual-stiffness flooring (DSF) has previously shown promise in reducing such morbidity in experimental models. This study set out to measure the impact of SmartCell flooring on falls-related morbidity in a nursing home. All falls occurring at an Arizona nursing home between July 1, 2008, and December 31, 2010, were reviewed for age, sex, diagnosis of osteoporosis, number of medications, history of previous falls, type of flooring (normal vs DSF), time of day, type of injury, and resulting actions. Fall-related outcomes were compared across room types using chi-square and logistic regression methods. Eighty-two falls on the DSF were compared with 85 falls on the regular floor. There was a tendency for residents falling on DSF to have less bruising and abrasions, while having more redness and cuts. There were 2 fractures on regular flooring (2.4% fracture rate) and none on the DSF flooring (0% fracture rate). The fracture rate of 2.4% of falls on the regular floor is consistent with previous reports in the literature, whereas a 0% rate found on the DSF floor is a clinically significant improvement. This suggests that DSF may be a practical approach for institutions and consumers to reduce fall-related injuries. A larger scale controlled study to confirm these encouraging preliminary findings is warranted. Copyright © 2013 American Medical Directors Association, Inc. Published by Elsevier Inc. All rights reserved.
Leclercq, S; Saulnier, H
2001-01-01
Slips contribute to 12% of occupational accidents. A slip resistant floor is a mean to prevent slipping accidents occurring in workshops. Floor slip resistance is often evaluated by measuring a friction index, proportional to the force opposing slipping of a reference elastomer on the floor surface under test. When implementing a portable appliance, slip resistance measurements carried out on lubricated floors were not stabilized. The authors advanced the hypothesis of oil impregnating the elastomer. A new elastomer suited to in-situ measurement has been developed to achieve stable measuring conditions. This study highlights the fact that the nature and characteristics of a reference elastomer must be specified when slip resistance measurements are carried out.
Research on Vibration Test in Urban Indoor Substation
NASA Astrophysics Data System (ADS)
Ma, Yuchao; Mo, Juan; Xu, Jin; Fan, Baozhen
2018-01-01
The problem of vibration and noise of urban indoor substations has becoming more and more socially concerned.The urban indoor substation of 110kV and its conjoined buildings were taken as the research object and the vibration tests of the transformer and each floor slab were respectively carried out.The sound vibration characteristics and sound transmission rules of the urban indoor substation were obtained through the time-frequency analysis and coherence analysis of the test data. The vibration spectrum of transformer body was mainly 100Hz together with its multiplying factors and the vibration characteristics of the floor slab were basically the same as those of the transformer body. it is crucial to control the vibration and noise transmission in the equipment floor of the urban indoor substation.
Dance floor mechanical properties and dancer injuries in a touring professional ballet company.
Hopper, Luke S; Allen, Nick; Wyon, Matthew; Alderson, Jacqueline A; Elliott, Bruce C; Ackland, Timothy R
2014-01-01
The mechanical properties of the floors used by dancers have often been suggested to be associated with injury, yet limited etiological evidence is available to support this hypothesis. The dance floors at three theatres regularly used by a touring professional ballet company were mechanically quantified with the aim of comparing floor properties with injury incidence in dancers. Cross sectional. Test points on the floors were quantified in accordance with European Sports Surface Standard protocols for force reduction. Injuries and associated variables occurring within the ballet company dancers during activity on the three floors were recorded by the company's medical staff. An injury was recorded if a dancer experienced an incident that restricted the dancer from performing all normal training or performance activities for a 24 h period. Injuries were delimited to those occurring in the lower limbs or lumbar region during non-lifting tasks. Floor construction varied between venues and a range of floor mechanical properties were observed. None of the floors complied with the range of force reduction values required by the European Sport Surface Standards. The highest injury rate was observed on the floor with the greatest variability of force reduction magnitudes. No difference in injury frequency was observed between the venues with the highest and lowest mean force reduction magnitudes. Professional dancers can be required to perform on floors that may be inadequate for safe dance practice. Intra-floor force reduction variability may have a stronger association with injury risk than mean floor force reduction magnitude. Copyright © 2013 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
Quenneville, Cheryl E; Fournier, Ed; Shewchenko, Nicholas
2017-09-01
The lower legs are at risk of substantial injury during events such as frontal automotive crashes and antivehicular mine blasts. Loading to occupants can be assessed using an instrumented anthropomorphic test device (ATD), whose measurements can be compared to established injury criteria. NATO's AEP-55 STANAG 4569 recognizes two surrogates for lower leg injury assessments from impacts with intruding floor pans resulting from underbelly blast loads; (1) the rigid Hybrid III instrumented lower leg, and; (2) the compliant MILitary Lower eXtremity (MIL-LX). The established injury criterion for the Hybrid III leg specifies a maximum lower tibia compressive load of 5.4 kN, whereas the MIL-LX limit is 2.6 kN measured at the upper tibia for similar injury severity levels. The difference in compliance between the two legs could affect the evaluation of protection levels, resulting in an over- or under-estimation of the force attenuation of energy attenuating (EA) floor mats. The responses of the two lower leg surrogates were evaluated at impact velocities up to 12 m/s, representing floor intrusions during antivehicle mine blasts. An air cannon was used to accelerate a rigid or padded floor plate into the sole of the surrogate lower legs, loading them axially, in order to assess the protective capability of commercial EA floor mats. The peak load from the lower and upper load cells in the Hybrid III and MIL-LX legs were compared to identify at what point their respective injury criteria would be exceeded in both the padded and unpadded conditions. Comparisons of the surrogate legs' responses resulted in different evaluations of risk, with the Hybrid III leg exceeding its limit at an impact speed of 6.0 m/s, and the MIL-LX exceeding its limit at 5.5 m/s (for tests including an EA product). Furthermore, the inclusion of an EA mat had a greater relative protective effect on the Hybrid III than the MIL-LX leg, with padding reducing the force to 17 to 34% of the unpadded condition for the Hybrid III, versus 67 to 89% of the unpadded condition for the MIL-LX. The load reduction was found to be velocity dependent for both surrogates. These results indicate that the two surrogates are not equivalent in their assessment of protective capability. Therefore, the selection of ATD leg for testing of EA mats (and other protective devices) will influence the evaluation of these systems, and more robust metrics are required to identify which is the most appropriate surrogate for evaluating injury to the lower limb. Reprint & Copyright © 2017 Association of Military Surgeons of the U.S.
NASA Astrophysics Data System (ADS)
Dixon, T. H.; Xie, S.; Malservisi, R.; Lembke, C.; Iannaccone, G.; Law, J.; Rodgers, M.; Russell, R.; Voss, N. K.
2017-12-01
A GPS-buoy system has been built and is currently undergoing test to measure precise 3D sea floor motion in the shallow (less than 200 m) continental shelf environment. Offshore deformation is undersampled in most subduction zones. In Cascadia, the shallow shelf environment constitutes roughly 20%-25% of the offshore area between the coastline and the trench. In the system being tested, the GPS receiver at the top of the buoy is connected to the sea floor through a rigid structure supported by a float. A similar design has been used by INGV (Italy) to measure vertical deformation on the sea floor near the Campi Flegrei caldera. Synthetic analysis shows that by adding a 3-axis digital compass to measure heading and tilt, along with kinematic GPS measurements, position of the anchor can be recovered to an accuracy of several centimeters or better, depending on water depth and GPS baseline length. Synthetic resolution tests show that our ability to detect shallow slow slip events on subduction plate boundaries can be greatly improved by adding offshore GPS-buoy sites.
Advanced low-floor vehicle (ALFV) specification research.
DOT National Transportation Integrated Search
2015-08-01
This report details the results of research on market comparison, operational cost efficiencies, and prototype tests conducted on : a novel design for an Advanced Low Floor Vehicle (ALFV), flex-route transit bus. Section I describes how the need for ...
Bukovsky, Antonin; Copas, Pleas; Caudle, Michael R; Cekanova, Maria; Dassanayake, Tamara; Asbury, Bridgett; Van Meter, Stuart E; Elder, Robert F; Brown, Jeffrey B; Cross, Stephanie B
2001-01-01
Background Pelvic floor disorders affect almost 50% of aging women. An important role in the pelvic floor support belongs to the levator ani muscle. The p27/kip1 (p27) protein, multifunctional cyclin-dependent kinase inhibitor, shows changing expression in differentiating skeletal muscle cells during development, and relatively high levels of p27 RNA were detected in the normal human skeletal muscles. Methods Biopsy samples of levator ani muscle were obtained from 22 symptomatic patients with stress urinary incontinence, pelvic organ prolapse, and overlaps (age range 38–74), and nine asymptomatic women (age 31–49). Cryostat sections were investigated for p27 protein expression and type I (slow twitch) and type II (fast twitch) fibers. Results All fibers exhibited strong plasma membrane (and nuclear) p27 protein expression. cytoplasmic p27 expression was virtually absent in asymptomatic women. In perimenopausal symptomatic patients (ages 38–55), muscle fibers showed hypertrophy and moderate cytoplasmic p27 staining accompanied by diminution of type II fibers. Older symptomatic patients (ages 57–74) showed cytoplasmic p27 overexpression accompanied by shrinking, cytoplasmic vacuolization and fragmentation of muscle cells. The plasma membrane and cytoplasmic p27 expression was not unique to the muscle cells. Under certain circumstances, it was also detected in other cell types (epithelium of ectocervix and luteal cells). Conclusions This is the first report on the unusual (plasma membrane and cytoplasmic) expression of p27 protein in normal and abnormal human striated muscle cells in vivo. Our data indicate that pelvic floor disorders are in perimenopausal patients associated with an appearance of moderate cytoplasmic p27 expression, accompanying hypertrophy and transition of type II into type I fibers. The patients in advanced postmenopause show shrinking and fragmentation of muscle fibers associated with strong cytoplasmic p27 expression. PMID:11696252
ETR HEAT EXCHANGER BUILDING, TRA644. FLOOR PLAN AND SECTIONS. PUMP ...
ETR HEAT EXCHANGER BUILDING, TRA-644. FLOOR PLAN AND SECTIONS. PUMP CUBICLES WITH PUMP MOTORS OUTSIDE CUBICLES. HEAT EXCHANGER EQUIPMENT. COOLANT PIPE TUNNEL ENTERS FROM REACTOR BUILDING. KAISER ETR-5582-MTR-644-A-3, 2/1956. INL INDEX NO. 532-0644-00-486-101294, REV. 6. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
12. CONTROL PANELS, WEST SIDE (LEFT & RIGHT), MAIN FLOOR: ...
12. CONTROL PANELS, WEST SIDE (LEFT & RIGHT), MAIN FLOOR: CENTER OF CLUSTERS, TOP BOX: MEGAWATT METER CENTER OF CLUSTERS, LOWER THREE BOXES: AMPERE METERS LEFT SIDE OF CLUSTERS: VOLTAGE CHART RECORDER RIGHT SIDE OF CLUSTERS: RECLOSE RELAY CENTER UNDER CLUSTERS: TESTING SWITCHES BELOW TESTING SWITCHES: BREAKER SWITCHES - Bonneville Power Administration South Bank Substation, I-84, South of Bonneville Dam Powerhouse, Bonneville, Multnomah County, OR
MTR, TRA603. SECOND FLOOR PLAN. OFFICES AND INSTRUMENT ROOM. STEEL ...
MTR, TRA-603. SECOND FLOOR PLAN. OFFICES AND INSTRUMENT ROOM. STEEL PARTITIONS ON EAST SIDE OF INSTRUMENT ROOM. DETAIL OF COLUMN ENCASEMENTS. STAIRWAYS IN NORTH AND SOUTH CORNERS. PASSENGER ELEVATION. BLAW-KNOX 3150-803-3, 7/1950. INL INDEX NO. 531-0603-00-098-100562, REV. 6. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Exclusive queueing model including the choice of service windows
NASA Astrophysics Data System (ADS)
Tanaka, Masahiro; Yanagisawa, Daichi; Nishinari, Katsuhiro
2018-01-01
In a queueing system involving multiple service windows, choice behavior is a significant concern. This paper incorporates the choice of service windows into a queueing model with a floor represented by discrete cells. We contrived a logit-based choice algorithm for agents considering the numbers of agents and the distances to all service windows. Simulations were conducted with various parameters of agent choice preference for these two elements and for different floor configurations, including the floor length and the number of service windows. We investigated the model from the viewpoint of transit times and entrance block rates. The influences of the parameters on these factors were surveyed in detail and we determined that there are optimum floor lengths that minimize the transit times. In addition, we observed that the transit times were determined almost entirely by the entrance block rates. The results of the presented model are relevant to understanding queueing systems including the choice of service windows and can be employed to optimize facility design and floor management.
Research on Upgrading Structures for Host and Risk Area Shelters
1982-09-01
both "as-built" and upgraded configurations. These analysis and prediction techniques have been applied to floors and roofs constructed of many...scale program and were previously applied to full-scale wood floor tests (Ref. 2). TEST ELEMENTS AND PROCEDURES Three tests were conducted on 8-inch...weights. A 14,000-lb crane counterweight was used for the preload, applying a load of 7,000 lb to each one-third point on the plank. The drop weight was
Drahota, Amy; Gal, Diane; Windsor, Julie; Dixon, Simon; Udell, Julie; Ward, Derek; Soilemezi, Dia; Dean, Taraneh; Severs, Martin
2011-12-01
Falls are an issue disproportionately affecting older people who are at increased risk of falls and injury. This protocol describes a pilot study investigating shock-absorbing flooring for fall-related injuries in wards for older people. To inform future research by evaluating fall-related injuries on the intervention and existing flooring, assessing the sustainability of the flooring in ward environments, estimating the cost-effectiveness of the floor and assessing how the floor affects patients and other users. This study uses mixed methods a pilot cluster randomised controlled trial, observation via mechanical testing and interviews. Eight participating wards (clusters) are randomised using a computer-generated list. No blinding is incorporated into the study. Each site has a baseline period of approximately 6 months. Then, four sites receive the intervention floor, while four continue using standard floors. Sites are then followed up for approximately 1 year. Any person admitted to a bed in the 'study area' of a participating ward can be entered into the trial. Orientated patients, visitors and any hospital staff who use the floor in a study area are eligible for inclusion in an interview. An 8.3 mm thick vinyl floor covering with polyvinyl chloride foam backing (Tarkett Omnisports EXCEL). The primary outcome is fall-related injuries. Severity of injuries, falls, cost-effectiveness, user views and mechanical performance (shock absorbency and slip resistance) are also being assessed.
Modality dependence and intermodal transfer in the Corsi Spatial Sequence Task: Screen vs. Floor.
Röser, Andrea; Hardiess, Gregor; Mallot, Hanspeter A
2016-07-01
Four versions of the Corsi Spatial Sequence Task (CSST) were tested in a complete within-subject design, investigating whether participants' performance depends on the modality of task presentation and reproduction that put different demands on spatial processing. Presentation of the sequence (encoding phase) and the reproduction (recall phase) were each carried out either on a computer screen or on the floor of a room, involving actual walking in the recall phase. Combinations of the two different encoding and recall procedures result in the modality conditions Screen-Screen, Screen-Floor, Floor-Screen, and Floor-Floor. Results show the expected decrease in performance with increasing sequence length, which is likely due to processing limitations of working memory. We also found differences in performance between the modality conditions indicating different involvements of spatial working memory processes. Participants performed best in the Screen-Screen modality condition. Floor-Screen and Floor-Floor modality conditions require additional working memory resources for reference frame transformation and spatial updating, respectively; the resulting impairment of the performance was about the same in these two conditions. Finally, the Screen-Floor modality condition requires both types of additional spatial demands and led to the poorest performance. Therefore, we suggest that besides the well-known spatial requirements of CSST, additional working memory resources are demanded in walking CSST supporting processes such as spatial updating, mental rotation, reference frame transformation, and the control of walking itself.
Knowledge of the pelvic floor in nulliparous women
Neels, Hedwig; Wyndaele, Jean-Jacques; Tjalma, Wiebren A. A.; De Wachter, Stefan; Wyndaele, Michel; Vermandel, Alexandra
2016-01-01
[Purpose] Proper pelvic floor function is important to avoid serious dysfunctions including incontinence, prolapse, and sexual problems. The current study evaluated the knowledge of young nulliparous women about their pelvic floor and identified what additional information they wanted. [Subjects and Methods] In this cross-sectional survey, a validated, 36 item questionnaire was distributed to 212 nulliparous women. The questionnaire addressed demography, pelvic floor muscles, pelvic floor dysfunction, and possible information sources. Descriptive statistics were generated for all variables. Stability and validity testing were performed using Kappa statistics and intra class correlation coefficients to define agreement for each question. The study was approved by the ethics Committee (B300201318334). [Results] Using a VAS scale (0 to 10), the women rated their knowledge about the pelvic floor as a mean of 2.4 (SD 2.01). A total of 93% of the women were insufficiently informed and requested more information; 25% had concerns about developing urinary incontinence, and 14% about fecal incontinence. Many of the women were unaware what pelvic floor training meant. [Conclusion] There was a significant lack of knowledge about pelvic floor function among nulliparous women. The majority of nulliparous women expressed a need for education, which might offer a way to reduce dysfunction. PMID:27313364
Kansy, Katinka; Mueller, Andreas Albert; Mücke, Thomas; Koersgen, Friederike; Wolff, Klaus Dietrich; Zeilhofer, Hans-Florian; Hölzle, Frank; Pradel, Winnie; Schneider, Matthias; Kolk, Andreas; Smeets, Ralf; Acero, Julio; Haers, Piet; Ghali, G E; Hoffmann, Jürgen
2017-12-01
Microvascular surgery following tumor resection has become an important field of oral maxillofacial surgery (OMFS). Following the results on general aspects of current reconstructive practice in German-speaking countries, Europe and worldwide, this paper presents specific concepts for the management of resection and reconstruction of T1/T2 squamous cell carcinoma (SCC) of the anterior floor of the mouth and tongue. The DOESAK questionnaire was distributed in three different phases to a growing number of maxillofacial units worldwide. Within this survey, clinical patient settings were presented to participants and center-specific treatment strategies were evaluated. A total of 188 OMFS units from 36 different countries documented their treatment strategies for T1/T2 anterior floor of the mouth squamous cell carcinoma and tongue carcinoma. For floor of mouth carcinoma close to the mandible, a wide variety of concepts are presented: subperiosteal removal of the tumor versus continuity resection of the mandible and reconstruction ranging from locoregional closure to microvascular bony reconstruction. For T2 tongue carcinoma, concepts are more uniform. These results demonstrate the lack of evidence and the controversy of different guidelines for the extent of safety margins and underline the crucial need of global prospective randomized trials on this topic to finally obtain evidence for a common guideline based on a strong community of OMFS units. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. All rights reserved.
19. VIEW OF INTERIOR OF BUILDING 220 SECOND FLOOR, FROM ...
19. VIEW OF INTERIOR OF BUILDING 220 SECOND FLOOR, FROM THE FEMALE MEDIUM SECURITY AREA FACING THE FEMALE MEDIUM SECURITY SLEEPING AREA. THE FEMALE CELL BLOCK DOOR IN SHOWN ON THE RIGHT OF PHOTO. THE SLEEPING AREA IS IN THE CENTER OF PHOTO. - U.S. Naval Base, Pearl Harbor, Brig, Neville Way near Ninth Street at Marine Barracks, Pearl City, Honolulu County, HI
Li, Ning; Tsushima, Eiki; Tsushima, Hitoshi
2013-04-05
Use of hip protectors and compliant flooring has been recommended for preventing hip fracture due to falls. We aimed to identify the factors attenuating forces in falls by comparing and analyzing the impact forces occurring with various combinations of hip protectors and flooring materials. We designed a simplified pendulum device to simulate the impact force at the hip during falling. The impact force was measured on pressure-sensitive recording film under combined conditions of two kinds of hip protector (hard or soft shell) and three kinds of floor material (concrete, wooden, or tatami matting). We then calculated the percentage force attenuation under each test condition compared with the use of a concrete floor and no hip protector. All the tests using tatami matting reduced the impact to below the average fracture threshold of elderly people (3472N). A combination of tatami and soft hip protector provided the best attenuation (72.5%). Multiple regression analyses showed that use of tatami matting and a soft hip protector had the biggest force-attenuation effect. The soft hip protector gave better percentage force attenuation than did the hard one. Use of tatami matting as a flooring material could be an effective strategy for helping prevent hip fractures. Copyright © 2013 Elsevier Ltd. All rights reserved.
HEALTH AND SAFETY BUILDING, TRA667. SOUTH AND WEST ELEVATIONS. FLOOR ...
HEALTH AND SAFETY BUILDING, TRA-667. SOUTH AND WEST ELEVATIONS. FLOOR PLAN AND ROOM DESIGNATIONS. NOTE PAIR OF ENTRY DOORS IN WEST ELEVATION FOR MEN AND WOMEN. CONCRETE T-BEAMS. F.C. TORKELSON CO. 842-MTR-667-A1, 1/1963. INL INDEX NO. 531-0667-00-851-151143, REV. 4. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
ETR, TRA642. ON GROUND FLOOR, CAMERA LOOKS SOUTHWEST INTO PIT. ...
ETR, TRA-642. ON GROUND FLOOR, CAMERA LOOKS SOUTHWEST INTO PIT. CANAL STRUCTURE IS AT RIGHT OF CENTER WITH RECTANGULAR OPENING TO BE MATED WITH THE DE-FUELING MECHANISM THAT WILL DEPOSIT FUEL RODS INTO THE WORKING CANAL. INL NEGATIVE NO. 56-3710. R.G. Larsen, Photographer, 11/13/1956 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
PROCESS WATER BUILDING, TRA605. SECTIONS B, C AND D SHOW ...
PROCESS WATER BUILDING, TRA-605. SECTIONS B, C AND D SHOW RELATIONSHIP BETWEEN FLASH EVAPORATORS (ABOVE) AND SEAL AND SUMP TANKS (BELOW). BASEMENT FLOOR IS BELOW GRADE; FIRST FLOOR, ABOVE GRADE. SHIELDING TOLERANCES. BLAW-KNOX 3150-5-7, 8/1950. INL INDEX NO. 531-605-00-098-100012, REV. 2. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Verelst, M; Leivseth, G
2004-01-01
The purpose of this study was to investigate whether there is a relationship between changes in the diameter of the urogenital hiatus and force developed in pelvic floor musculature. In addition, we wanted to examine the reliability of the method that measures force development in the pelvic floor in the transverse direction of the urogenital hiatus. Passive and total force in the pelvic floor was measured with an intra-vaginal device in 20 healthy parous volunteers. The measurements were done with a consecutively increasing diameter in the transverse plane of the urogenital hiatus. The procedure was repeated with a few days interval. The measurements show an increase in force with an increasing device-diameter. The results are reliable at all the diameters tested, estimated by the within-subject day-to-day variability which was non-significant. The 40 mm diameter device is most favourable, estimated by Bland Altman plots of the test-retest measurements. Force development in pelvic floor muscles increased as a function of vaginal diameter when measured in the frontal plane. The measurements were reliable at all the different diameters chosen. 2004 Wiley-Liss, Inc.
Kim, Sumin
2010-04-15
This paper assesses the reproducibility of testing formaldehyde and TVOC emission behavior from wood flooring composites bonded by urea-formaldehyde resin at various manufacturing steps for surface finishing materials. The surface adhesion step of laminate flooring for this research was divided into two steps; HDF only and HDF with LPMs. In the case of engineered flooring, the manufacturing steps were divided into three steps; plywood only, fancy veneer bonded on plywood and UV coated on fancy veneer with plywood. Formaldehyde and VOCs emission decreased at the process of final surface finishing materials; LPMs were applied on the surface of HDF for laminate flooring. Although emissions increased when fancy veneer was bonded onto plywood in the case of engineered flooring, emission was dramatically reduced up to similar level with plywood only when final surface finishing; UV-curable coating was applied on fancy veneer. This study suggests that formaldehyde and VOCs emission from floorings can be controlled at manufacturing steps for surface finishing. 2009 Elsevier B.V. All rights reserved.
Sloto, Ronald A.
1997-01-01
A suite of borehole geophysical logs and heat-pulse-flowmeter measurements run in the former production well at the John Wagner and Sons, Inc. plant indicate two zones of borehole flow. In the upper part of the well, water enters the borehole through a fracture at 90 ft (feet) below floor level, moves upward, and exits the borehole through a fracture at 72 ft below floor level. Water also enters the borehole through fractures at 205-213, 235, and 357 ft below floor level; moves downward; and exits the borehole through fractures at 450-459, 468-470, and 483-490 ft below floor level. Five zones were selected for aquifer-isolation (packer) tests on the basis of borehole geophysical logs. The zones were isolated using a straddle-packer assembly. The lowermost three zones (below 248, 223 to 248, and 198 to 223 ft below floor level) were hydraulically isolated from zones above and below. Specific capacities were 0.12, 0.034, and 0.15 gallons per minute per foot, respectively. The hydrograph from zone 2 (223 to 248 ft below floor level) showed interference from a nearby pumping well. For the upper two zones (81 to 106 and 57 to 81 ft below floor level), similar drawdowns in the isolated zone and the zones above and below the isolated zone indicate that these fractures are hydraulically connected outside the borehole in the unconfined part of the Stockton Formation. The specific capacity of zones 4 and 5 are similar—0.82 and 0.61, respectively.
Interior building details of Building A, dungeon cell adjacent to ...
Interior building details of Building A, dungeon cell adjacent to northwest cell: granite and brick threshold, poured concrete floors, plastered finished walls, vaulted veiling; northwesterly view - San Quentin State Prison, Building 22, Point San Quentin, San Quentin, Marin County, CA
Experiment on the concrete slab for floor vibration evaluation of deteriorated building
NASA Astrophysics Data System (ADS)
Hong, S. U.; Na, J. H.; Kim, S. H.; Lee, Y. T.
2014-08-01
Damages from noise and vibration are increasing every year, and most of which are noises between floors in deteriorated building caused by floor impact sound. In this study, the floor vibration of the deteriorated buildings constructed with the concrete slabs of thickness no more than 150 mm was evaluated by the vibration impact sound. This highly reliable study was conducted to assess floor vibration according with the serviceability evaluation standard of Reiher / Meister and Koch and vibration evaluation standard of ISO and AIJ. Designed pressure for the concrete slab sample of floor vibration assessment was 24MPa, and the sample was manufactured pursuant to KS F 2865 and JIS A 1440-2 with size of 3200 mm × 3200 mm × 140 mm. Tests were conducted twice with accelerometers, and Fast Fourier Transform was performed for comparative analysis by the vibration assessment criteria. The peak displacement from Test 1 was in the range of 0.00869 - 0.02540 mm; the value of peak frequency ranged from 18 to 27 Hz, and the average value was 22Hz. The peak acceleration value from Test 2 was in the range of 0.47 - 1.07 % g; the value of peak frequency was 18.5 - 22.57 Hz, and the average was 21Hz. The vibration was apparently recognizable in most cases according to the Reiher/Meister standard. In case of Koch graph for the damage assessment of the structure, the vibration was at the medium level and causes no damage to the building structure. The measured vibration results did not exceed the damage limit or serviceability limit of building according to the vibration assessment criteria of ISO and residential assessment guidelines provided by Architectural Institute of Japan (AIJ).
Contemporary bloodletting in cardiac surgical care.
Koch, Colleen G; Reineks, Edmunds Z; Tang, Anne S; Hixson, Eric D; Phillips, Shannon; Sabik, Joseph F; Henderson, J Michael; Blackstone, Eugene H
2015-03-01
Health care providers are seldom aware of the frequency and volume of phlebotomy for laboratory testing, bloodletting that often leads to hospital-acquired anemia. Our objectives were to examine the frequency of laboratory testing in patients undergoing cardiac surgery, calculate cumulative phlebotomy volume from time of initial surgical consultation to hospital discharge, and propose strategies to reduce phlebotomy volume. From January 1, 2012 to June 30, 2012, 1,894 patients underwent cardiac surgery at Cleveland Clinic; 1,867 had 1 hospitalization and 27 had 2. Each laboratory test was associated with a test name and blood volume. Phlebotomy volume was estimated separately for the intensive care unit (ICU), hospital floors, and cumulatively. A total of 221,498 laboratory tests were performed, averaging 115 tests per patient. The most frequently performed tests were 88,068 blood gas analyses, 39,535 coagulation tests, 30,421 complete blood counts, and 29,374 metabolic panels. Phlebotomy volume differed between ICU and hospital floors, with median volumes of 332 mL and 118 mL, respectively. Cumulative median volume for the entire hospital stay was 454 mL. More complex procedures were associated with higher overall phlebotomy volume than isolated procedures; eg, combined coronary artery bypass grafting (CABG) and valve procedure median volume was 653 mL (25th/75th percentiles, 428 of 1,065 mL) versus 448 mL (284 of 658 mL) for isolated CABG and 338 mL (237 of 619) for isolated valve procedures. We were astonished by the extent of bloodletting, with total phlebotomy volumes approaching amounts equivalent to 1 to 2 red blood cell units. Implementation of process improvement initiatives can potentially reduce phlebotomy volumes and resource utilization. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
This report describes the implementation and testing of control measures to reduce airborne asbestos generated by the drilling of asbestos-containing flooring materials, an OSHA Class III asbestos maintenance activity. Bosch 11224 and 11222 rotary drills were fitted with shrouds ...
DOT National Transportation Integrated Search
2014-08-01
The Advanced Structures and Composites Center at the University of Maine (UMaine) performed live load testing : and rating adjustment factor analysis for three truss bridges. The Maine Department of Transportation (DOT) : indicated that the floor bea...
Lachance, Chantelle C; Feldman, Fabio; Laing, Andrew C; Leung, Pet Ming; Robinovitch, Stephen N; Mackey, Dawn C
2016-12-01
A promising strategy for reducing the incidence and severity of fall-related injuries in long-term care (LTC) is to decrease the ground surface stiffness, and the subsequent forces applied to the body parts at impact, through installation of compliant flooring that does not substantially affect balance or mobility. Definitive evidence of the effects of compliant flooring on fall-related injuries in LTC is lacking. The Flooring for Injury Prevention (FLIP) Study is designed to address this gap. The FLIP Study is a 4-year, parallel-group, 2-arm, randomised controlled superiority trial of flooring in 150 resident rooms at a LTC site. The primary objective is to determine whether compliant flooring reduces serious fall-related injuries relative to control flooring. Intervention (2.54 cm SmartCells compliant; 74 rooms) and control (2.54 cm plywood; 76 rooms) floorings were installed over the top of existing concrete floors and covered with identical 2.00 mm vinyl. The primary outcome is serious fall-related injury, defined as any impact-related injury due to a fall in a study room that results in Emergency Department visit or hospital admission. Secondary outcomes include minor fall-related injury, any fall-related injury, falls, number of fallers, fractures, and healthcare utilisation and costs for serious fall-related injuries. Randomisation of study rooms, and residents in rooms, was stratified by residential unit, and flooring assignments were concealed. Outcome ascertainment began September 2013. Results from the FLIP Study will provide evidence about the effects of compliant flooring on fall-related injuries in LTC and will guide development of safer environments for vulnerable older adults. NCT01618786. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nixon, R.
The deterioration of concrete structures due to chloride induced reinforcing steel corrosion such as in elevated concrete floor slabs, columns, and beams in bleach plants is a constant and growing problem within the pulp and paper industry. In general, the condition analysis methods used for assessing the extent of bleach plant concrete degradation include physical testing of drilled concrete core samples, chloride ion concentration testing, half-cell potential measurements, and physical sounding of concrete surfaces, i.e. chain drag for topside surfaces and hammer sounding of soffit surfaces. While this paper does not promote any vastly different evaluative methods, it does sharemore » learnings relative to interpreting the data provided by these typical test methods. It further offers some recommendations on how to improve the use of these typical evaluation techniques and offers some other test methods which should be considered as valuable additions for such evaluations. One of the most common methods which has been used in the past for large scale bleach plant concrete restoration has been the application of site dry mixed shotcrete for rebuilding the soffits of floor slabs and the faces of columns and beams. More often than not, bulk mixed dry shotcrete repairs have not been cost-effective because they prematurely failed due to excessive hydration related shrinkage cracking, lack of sufficient adhesion to the parent concrete substrate or other problems related to poor durability or construction practice.« less
Tactile Imaging Markers to Characterize Female Pelvic Floor Conditions.
van Raalte, Heather; Egorov, Vladimir
2015-08-01
The Vaginal Tactile Imager (VTI) records pressure patterns from vaginal walls under an applied tissue deformation and during pelvic floor muscle contractions. The objective of this study is to validate tactile imaging and muscle contraction parameters (markers) sensitive to the female pelvic floor conditions. Twenty-two women with normal and prolapse conditions were examined by a vaginal tactile imaging probe. We identified 9 parameters which were sensitive to prolapse conditions ( p < 0.05 for one-way ANOVA and/or p < 0.05 for t -test with correlation factor r from -0.73 to -0.56). The list of parameters includes pressure, pressure gradient and dynamic pressure response during muscle contraction at identified locations. These parameters may be used for biomechanical characterization of female pelvic floor conditions to support an effective management of pelvic floor prolapse.
Tactile Imaging Markers to Characterize Female Pelvic Floor Conditions
van Raalte, Heather; Egorov, Vladimir
2015-01-01
The Vaginal Tactile Imager (VTI) records pressure patterns from vaginal walls under an applied tissue deformation and during pelvic floor muscle contractions. The objective of this study is to validate tactile imaging and muscle contraction parameters (markers) sensitive to the female pelvic floor conditions. Twenty-two women with normal and prolapse conditions were examined by a vaginal tactile imaging probe. We identified 9 parameters which were sensitive to prolapse conditions (p < 0.05 for one-way ANOVA and/or p < 0.05 for t-test with correlation factor r from −0.73 to −0.56). The list of parameters includes pressure, pressure gradient and dynamic pressure response during muscle contraction at identified locations. These parameters may be used for biomechanical characterization of female pelvic floor conditions to support an effective management of pelvic floor prolapse. PMID:26389014
Gynecological Surgery and Low Back Pain in Older Women
Ericksen, Jeffery; Pidcoe, Peter E.; Ketchum-McKinney, Jessica M.; Burnet, Evie N.; Huang, Emily; Wilson, James C.; Hoogstad, Vincent
2010-01-01
Objective: To determine sacroiliac joint compliance characteristics and pelvic floor movements in older women relative to gynecological surgery history and back pain complaints. Design: Single-visit laboratory measurement. Setting: University clinical research center. Participants: Twenty-five women aged 65 years or older. Outcome Measures: Sacroiliac joint compliance measured by Doppler imaging of vibrations and ultrasound measures of pelvic floor motion during the active straight leg raise test. Results: Doppler imaging of vibrations demonstrated test reliability ranging from 0.701 to 0.898 for detecting vibration on the ilium and sacrum sides of the sacroiliac joint. The presence of low-back pain or prior gynecological surgery was not significantly associated with a difference in the compliance or laxity symmetry of the sacroiliac joints. No significant difference in pelvic floor movement was found during the active straight leg raise test between subject groups. All P values were ≥.4159. Conclusions: Prior gynecological surgery and low-back pain were not significantly associated with side-to-side differences in the compliance of the sacroiliac joints or in significant changes in pelvic floor movement during a loading maneuver in a group of older women. PMID:23569659
NASA Technical Reports Server (NTRS)
Jackson, Karen E.; Fasanella, Edwin L.; Lyle, Karen H.
2003-01-01
A 25-fps vertical drop test of a 1/5-scale model composite fuselage section was conducted to replicate a previous test of a full-scale fuselage section. The purpose of the test was to obtain experimental data characterizing the impact response of the 1/5-scale model fuselage section for comparison with the corresponding full-scale data. This comparison is performed to assess the scaling procedures and to determine if scaling effects are present. For the drop test, the 1/5-scale model fuselage section was configured in a similar manner as the full-scale section, with lead masses attached to the floor through simulated seat rails. Scaled acceleration and velocity responses are compared and a general assessment of structural damage is made. To further quantify the data correlation, comparisons of the average acceleration data are made as a function of floor location and longitudinal position. Also, the percentage differences in the velocity change (area under the acceleration curve) and the velocity change squared (proportional to kinetic energy) are compared as a function of floor location. Finally, correlation coefficients are calculated for corresponding 1/5- and full-scale data channels and these values are plotted versus floor location. From a scaling perspective, the differences between the 1/5- and full-scale tests are relatively small, indicating that appropriate scaling procedures were used in fabricating the test specimens and in conducting the experiments. The small differences in the scaled test data are attributed to minor scaling anomalies in mass, potential energy, and impact attitude.
NASA Technical Reports Server (NTRS)
Kempf, Michael J.; Chen, Fei; Kern, Roger; Venkateswaran, Kasthuri
2005-01-01
While the microbial diversity of a spacecraft assembly facility at the Jet Propulsion Laboratory (Pasadena, CA) was being monitored, H2O2-resistant bacterial strains were repeatedly isolated from various surface locations. H2O2 is a possible sterilant for spacecraft hardware because it is a low-temperature process and compatible with various modern-day spacecraft materials, electronics, and components. Both conventional biochemical testing and molecular analyses identified these strains as Bacillus pumilus. This Bacillus species was found in both unclassified (entrance floors, anteroom, and air-lock) and classified (floors, cabinet tops, and air) locations. Both vegetative cells and spores of several B. pumilus isolates were exposed to 5% liquid H2O2 for 60 min. Spores of each strain exhibited higher resistance than their respective vegetative cells to liquid H2O2. Results indicate that the H2O2 resistance observed in both vegetative cells and spores is strain-specific, as certain B. pumilus strains were two to three times more resistant than a standard Bacillus subtilis dosimetry strain. An example of this trend was observed when the type strain of B. pumilus, ATCC 7061, proved sensitive, whereas several environmental strains exhibited varying degrees of resistance, to H2O2. Repeated isolation of H2O2-resistant strains of B. pumilus in a clean-room is a concern because their persistence might potentially compromise life-detection missions, which have very strict cleanliness and sterility requirements for spacecraft hardware.
Experimental Investigation of Properties of Foam Concrete for Industrial Floors in Testing Field
NASA Astrophysics Data System (ADS)
Vlcek, Jozef; Drusa, Marian; Scherfel, Walter; Sedlar, Bronislav
2017-12-01
Foam concrete (FC), as a mixture of cement, water, additives and technical foam, is well known for more than 30 years. It is building material with good mechanical properties, low thermal conductivity, simple and even high technological treatment. Foam concrete contains closed void pores, what allows achieving low bulk density and spare of raw materials. Thanks to its properties, it is usable as a replacement of conventional subbase layers of the industrial floors, the transport areas or as a part of the foundation structures of the buildings. Paper presents the preparation of the testing field (physical model) which was created for experimental investigation of the foam concrete subbase layer of the industrial floor in a real scale.
Kobayashi, Wataru; Kukobota, Kosei; Ito, Ryohei; Sakaki, Hirotaka; Nakagawa, Hirosi; Teh, Beng Gwan
2016-06-01
The purpose of this study was to compare quality of life (QoL) and the survival rate after surgery with and without radiotherapy versus superselective intra-arterial chemoradiotherapy (SSIACRT) for advanced cancer of the tongue and floor of the mouth. Patients with stage III and IV squamous cell carcinoma of the tongue and floor of the mouth treated between 2000 and 2013 were included in this study. The predictor variables were surgery without radiotherapy, surgery followed by radiotherapy, and SSIACRT. The outcome variables were QoL and the survival rate. The University of Washington QoL questionnaire (UW-QOL) was used for evaluation of QoL. The Kaplan-Meier method was used to estimate the overall survival rate. The UW-QOL was analyzed by analysis of covariance, and the survival rate was analyzed statistically by the log-rank test. Sixty-two patients were eligible for this study. Of these, 13 were treated by surgery without radiotherapy, 29 were treated by surgery plus radiotherapy, and 20 were treated by SSIACRT. The SSIACRT group had the best UW-QOL scores among the 3 groups. The 5-year Kaplan-Meier disease-specific survival rates for these groups were 92.9%, 62.9%, and 83.2%, respectively, with no significant difference (P = .20) shown. The QoL scores of the SSIACRT group were the best among the 3 groups in most domains. The superiority of QoL and the survival rate in the SSIACRT group showed that SSIACRT should be preferred in managing advanced cancer of the tongue and floor of the mouth. Copyright © 2016 The American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Anatomic Site Based Ploidy Analysis of Oral Premalignant Lesions
Islam, M. N.; Kornberg, L.; Veenker, E.; Cohen, D. M.
2009-01-01
The location of oral leukoplakia correlates strongly with the probability of finding dysplastic or malignant alterations at biopsy. It is well established that early detection can dramatically improve the 5-year survival rates for oral squamous cell carcinomas. Since aneuploidy is predictive of future conversion to malignancy, we hypothesized that dysplastic lesions from high-risk sites (floor of mouth, tongue and lips) would exhibit greater aneuploidy than low-risk sites (palate, gingiva and buccal mucosa). Epithelial sections from 60 archival samples diagnosed as mild dysplasia (36 females, 20 males) from various high/low risk locations were stained with Blue Feulgen Stain for DNA Ploidy Analysis (Clarient, Aliso Viejo, CA) and ploidy was analyzed using a ChromaVision ACIS II (Clarient, ALiso Viejo, CA) Image cytometry system. A DNA histogram was generated using an image analyzing software that evaluated the amount of Feulgen stain which is proportional to the amount of nuclear DNA. An ANOVA analysis followed by the Student’s‘t’ test revealed significant differences between means (P ≤ 0.05). Lesions originating from lateral/ventral tongue (85%), floor of mouth (50%) and soft palate (44%) exhibited a higher frequency of aneuploidy than lesions from gingiva (22%) and lower lip (25%). This pilot study demonstrates that dysplastic lesions from high-risk sites such as the floor of the mouth and lateral/ventral tongue have higher frequency of aneuploidy. PMID:20237983
MTR MAIN FLOOR. MEN DEMONSTRATE INSERTION OF DUMMY PLUG INTO ...
MTR MAIN FLOOR. MEN DEMONSTRATE INSERTION OF DUMMY PLUG INTO AN MTR BEAM HOLE. ONE MAN CHECKS RADIATION LEVEL AT THE END OF THE UNIVERSAL COFFIN, WHILE ANOTHER USES TOOL TO INSERT PLUG INTO HOLE THROUGH COFFIN. MEN WEAR "ANTI-C" (ANTI-CONTAMINATION) CLOTHING. INL NEGATIVE NO. 6198. R.G. Larsen, Photographer, 6/27/1952 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
7. "CONTROL BUILDING; FLOOR PLAN, ELEVATIONS AND DETAILS." Specifications No. ...
7. "CONTROL BUILDING; FLOOR PLAN, ELEVATIONS AND DETAILS." Specifications No. OC1-59-53; Drawing No. 5841-A-1; D.O. SERIES AW1525/2 Rev. B. Stamped: RECORD DRAWING AS CONSTRUCTED. Below stamp: Contract No. 5619, Rev. B. Date: 7-8-59. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Firing Control Building, Test Area 1-100, northeast end of Test Area 1-100 Road, Boron, Kern County, CA
PROCESS WATER BUILDING, TRA605. FLOOR PLAN AND SECTION OF FLASH ...
PROCESS WATER BUILDING, TRA-605. FLOOR PLAN AND SECTION OF FLASH EVAPORATOR ROOM SHOWING ITS LOCATION ABOVE THE SEAL AND SUMP TANKS. PIPING TAKES WATER FROM SEAL TANK UPWARD TO FLASH EVAPORATORS AND THEN BACK DOWN TO SUMP TANK. BLAW-KNOX 3150-5-6, 8/1950. INL INDEX NO. 531-605-00-098-100011, REV. 3. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Mayoral, M; Paredes, P; Sieira, R; Vidal-Sicart, S; Marti, C; Pons, F
2014-01-01
The use of sentinel lymph node biopsy in squamous cell carcinoma of the oral cavity is still subject to debate although some studies have reported its feasibility. The main reason for this debate is probably due to the high false-negative rate for floor-of-mouth tumors per se. We report the case of a 54-year-old man with a T1N0 floor-of-mouth squamous cell carcinoma who underwent the sentinel lymph node procedure. Lymphoscintigraphy and SPECT/CT imaging were performed for lymphatic mapping with a conventional gamma camera. Sentinel lymph nodes were identified at right Ib, left IIa and Ia levels. However, these sentinel lymph nodes were difficult to detect intraoperatively with a gamma probe owing to the activity originating from the injection site. The use of a portable gamma camera made it possible to localize and excise all the sentinel lymph nodes. This case demonstrates the usefulness of this tool to improve sentinel lymph node detecting in floor-of-mouth tumors, especially those close to the injection area. Copyright © 2013 Elsevier España, S.L. and SEMNIM. All rights reserved.
Jeong, Yongsu; Epstein, Douglas J
2003-08-01
The establishment of the floor plate at the ventral midline of the CNS is dependent on an inductive signaling process mediated by the secreted protein Sonic hedgehog (Shh). To understand molecularly how floor plate induction proceeds we identified a Shh-responsive regulatory element that directs transgene reporter expression to the ventral midline of the CNS and notochord in a Shh-like manner and characterized critical cis-acting sequences regulating this element. Cross-species comparisons narrowed the activity of the Shh floor plate enhancer to an 88-bp sequence within intron 2 of Shh that included highly conserved binding sites matching the consensus for homeodomain, Tbx and Foxa transcription factors. Mutational analysis revealed that the homeodomain and Foxa binding sites are each required for activation of the Shh floor plate enhancer, whereas the Tbx site was required for repression in regions of the CNS where Shh is not normally expressed. We further show that Shh enhancer activity was detected in the mouse node from where the floor plate and notochord precursors derive. Shh reporter expression was restricted to the ventral (mesodermal) layer of the node in a pattern similar to endogenous Shh. X-gal-positive cells emerging from the node were only detected in the notochord lineage, suggesting that the floor plate and notochord arise from distinct precursors in the mouse node.
Terahop and Lawrence Livermore National LaboratoryStructural Fire RF Testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haugen, P; Pratt, G
The Georgia Public Safety Training Center's Live Fire Training Facility in Forsyth, GA is a three story structure constructed of rebar-reinforced concrete wall and floors. All the door and window coverings on the building are constructed of thick, plate metal to withstand the high temperatures generated inside the building during training exercises. All of the building's walls and floors are 1-foot thick, and regular concrete columns run up along the inside of the wall increasing the thickness to 20-inches in those locations. A center concrete staircase divides the structure in half. For typical exercises, fires are started in the backmore » right corner of the building on the first floor and in the front right corner on the second floor as shown in Figure 2. Due to the high heat generated during these exercises, measured at 300 F on the floor and 700 F near the ceilings, there were limited locations at which equipment could be placed that did not incorporate heat shielding, such as the Lawrence Livermore National Laboratory's UWB system. However, upon inspection of the building, two preferable locations were identified in which equipment could be placed that would be protected from the temperature extremes generated by the fires. These locations are identified in Figure 2 as the tested TX locations. These were preferred locations because, while they protected the hardware from temperature extremes, they also force the RF transmission path through the building to cross very near the fire locations and anticipated plasma generation regions. Both of the locations listed in Figure 2 were tested by the UWB equipment and found to be suitable deployment locations to establish a solid RF link for data collection. The transmission location on the first floor was ultimately chosen for use during the actual exercises because it was accessible to the data collection team during the exercises. This allowed them to remove the hardware once the testing was complete without having to wait for the entire day of exercises to complete. Unfortunately, RF transmission directly through the central location of the fire on the first floor was not possible, so the transmission path had to be shifted approximately 6-feet off the side of the fire's center. The corner where the fire was located on the first floor was re-enforced with a mixture of concrete and metal fibers for heat resistance. This material was highly reflective, permitting very little RF energy to pass through it. This phenomenon was also observed and verified by Terahop's testing, discussed in the next section. An image of these re-enforced walls and a close up of the actual wall material containing the metal fibers can bee seen in Figure 3.« less
An, Jae-Yoon; Kim, Sumin; Kim, Hyun-Joong
2011-03-15
Formaldehyde was measured with a desiccator, a 20 L chamber and the FLEC method. The formaldehyde emission rate from laminate was the highest at 32 °C using the desiccator, which then decreased with time. The formaldehyde emission using the 20 L small chamber and FLEC showed a similar tendency. There was a strong correlation between the formaldehyde and total volatile organic compounds (TVOCs) with both types of floorings using the two different methods. The formaldehyde emission rate and TVOC results were higher when tested using the FLEC method than with the 20 L small chamber method. The emission rate was affected by the joint edge length in laminate flooring. Toluene, ethylbenzene and xylene were the main VOCs emitted from laminate flooring, and there were more unidentified VOCs emitted than identified VOCs. The samples heated with a floor heating system emitted more formaldehyde than those heated using an air circulation system due to the temperature difference between the bottom panel and flooring. The TVOC emission level of the samples was higher when an air circulation system was used than when a floor heating system was used due to the high ventilation rate. Copyright © 2010 Elsevier B.V. All rights reserved.
Anatomic-histologic study of the floor of the mouth: the lingual lymph nodes.
Ananian, Sargis G; Gvetadze, Shalva R; Ilkaev, Konstantin D; Mochalnikova, Valeria V; Zayratiants, Georgiy O; Mkhitarov, Vladimir A; Yang, Xin; Ciciashvili, Aleksandr M
2015-06-01
The lingual lymph nodes are inconstant nodes located within the fascial/intermuscular spaces of the floor of the mouth. Oral tongue squamous cell carcinoma has been reported to recur and metastasize in lingual lymph nodes with poor prognosis. Lingual lymph nodes are not currently included in basic tongue squamous cell carcinoma surgery. Twenty-one cadavers (7 males, 14 females) were studied, aged from 57 to 94 years (mean age 76.3 years). The gross specimen of the floor of the mouth was divided into blocks: A (median nodes), B, B' (parahyoid), C, C' (paraglandular). Serial histological microslides were cut and stained with hematoxylin-eosin. Frequency of lingual lymph nodes in each block and their microscopic features were assessed. The lingual lymph nodes in overall number of 7 were detected in 5 of the 21 cadavers (23.8%). The total incidence of lingual lymph node was 33.3% (7 nodes/21 cadavers). Block A failed to demonstrate any lymph nodes (0%); Blocks B, B'-2 nodes (9.5%) and 2 nodes (9.5%), respectively; Blocks C, C'-1 node (4.8%) and 2 nodes (9.5%), respectively. The mean lingual lymph node length was 4.1 mm (from 1.4 to 8.7 mm), the mean thickness was 2.8 mm (from 0.8 to 7.5 mm). Five cadavers (23.8%) revealed mucosa-associated lymphoid tissue. Atrophic changes appeared in 4 (57.1%) lingual lymph nodes. The presence of lymph node-bearing tissue in the floor of the mouth is demonstrated. In account of resection radicalism and better local control the fat tissue of the floor of the mouth should be removed in conjunction to glossectomy. Further anatomic and clinical research is required to establish the role of lingual lymph node in oral squamous cell carcinoma recurrence and metastasis. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Investigation of Concrete Floor Vibration Using Heel-Drop Test
NASA Astrophysics Data System (ADS)
Azaman, N. A. Mohd; Ghafar, N. H. Abd; Azhar, A. F.; Fauzi, A. A.; Ismail, H. A.; Syed Idrus, S. S.; Mokhjar, S. S.; Hamid, F. F. Abd
2018-04-01
In recent years, there is an increased in floor vibration problems of structures like residential and commercial building. Vibration is defined as a serviceability issue related to the comfort of the occupant or damage equipment. Human activities are the main source of vibration in the building and it could affect the human comfort and annoyance of residents in the building when the vibration exceed the recommend level. A new building, Madrasah Tahfiz located at Yong Peng have vibration problem when load subjected on the first floor of the building. However, the limitation of vibration occurs on building is unknown. Therefore, testing is needed to determine the vibration behaviour (frequency, damping ratio and mode shape) of the building. Heel-drop with pace 2Hz was used in field measurement to obtain the vibration response. Since, the heel-drop test results would vary in light of person performance, test are carried out three time to reduce uncertainty. Natural frequency from Frequency Response Function analysis (FRF) is 17.4Hz, 16.8, 17.4Hz respectively for each test.
Wideman, R F; Hamal, K R; Stark, J M; Blankenship, J; Lester, H; Mitchell, K N; Lorenzoni, G; Pevzner, I
2012-04-01
Bacterial chondronecrosis with osteomyelitis (BCO) is the most common cause of lameness in commercial broilers. Bacteria entering the blood via translocation from the respiratory system or gastrointestinal tract spread hematogenously to the proximal epiphyseal-physeal cartilage of rapidly growing femora and tibiae, causing BCO. We tested the hypothesis that rearing broilers on wire flooring should increase the incidence of BCO by persistently imposing additional torque and shear stress on susceptible leg joints. We also tested the hypothesis that probiotics might attenuate bacterial translocation and thereby reduce the incidence of BCO. In 5 independent experiments using 4 commercial lines, broilers grown on wire flooring developed lameness attributable predominately to BCO. The fastest-growing birds were not necessarily the most susceptible to lameness on wire flooring, nor did the genders differ in susceptibility in the 2 experiments that included both male and female broilers. The pathogenesis of BCO is not instantaneous, and accordingly, many broilers that did not exhibit lameness, nevertheless, did possess early pathognomonic lesions. These subclinical lesions were equally likely to develop in the right or left leg. The lesion status of the proximal femoral head did not determine the lesion status of the ipsilateral or contralateral proximal tibial head and vice versa. Broilers reared on wire flooring consistently had higher incidences of lameness than hatch-mates reared on wood-shavings litter. Adding probiotics to the diet beginning at 1 d of age consistently reduced the incidence of lameness for broilers reared on wire flooring. These experiments indicate that probiotics administered prophylactically may constitute an alternative to antibiotics for reducing lameness attributable to BCO. Rearing broilers on wire flooring provides an important new research model for investigating the etiology, pathogenesis, and treatment strategies for BCO.
Investigation of Seal-to-Floor Effects on Semi-Span Transonic Models
NASA Technical Reports Server (NTRS)
Sleppy, Mark A.; Engel, Eric A.; Watson, Kevin T.; Atler, Douglas M.
2009-01-01
In an effort to achieve the maximum possible Reynolds number (Re) when conducting production testing for flight loads aerodynamic databases, it has been the preferred practice of The Boeing Company / Commercial Airplanes (BCA) -- Loads and Dynamics Group since the early 1990's to test large scale semi-span models in the 11- By 11-Foot Transonic Wind Tunnel (TWT) leg of the Unitary Plan Wind Tunnel (UPWT) at the NASA Ames Research Center (ARC). There are many problems related to testing large scale semi-span models of high aspect ratio flexible transport wings, such as; floor boundary layer effects, wing spanwise wall effects, solid blockage buoyancy effects, floor mechanical interference effects, airflow under the model effects, or tunnel flow gradient effects. For most of these issues, BCA has developed and implemented either standard testing methods or numerical correction schemes and these will not be discussed in this document. Other researchers have reported on semi-span transonic testing correction issues, however most of the reported research has been for low Mach testing. Some of the reports for low Mach testing address the difficult problem of preventing undesirable airflow under a semi-span model while ensuring unrestricted main balance functionality, however, for transonic models this issue has gone unresolved. BCA has been cognizant for sometime that there are marked differences in wing pressure distributions from semi-span transonic model testing than from full model or flight testing. It has been suspected that these differences are at least in part due to airflow under the model. Previous efforts by BCA to address this issue have proven to be ineffective or inconclusive and in one situation resulted in broken hardware. This paper reports on a Boeing-NASA collaborative investigation based on a series of small tests conducted between June 2006 and November 2007 in the 11 by 11 foot Transonic Wind Tunnel at NASA Ames on three large commercial jet transport configurations to assess the effects of sealing a semi-span model to the floor and to investigate efficient sealing and testing techniques. This document will show how sealing the model to the floor has a small but remarkably far reaching spanwise effect on wing pressures, wing local section forces and wing force summations.
Code of Federal Regulations, 2013 CFR
2013-04-01
... under the HUD building product standard and certification program for construction adhesives for wood... program for construction adhesives for wood floor systems. (a) Applicable standards. (1) All construction adhesives for field glued wood floor systems shall be designed, manufactured, and tested in compliance with...
Code of Federal Regulations, 2014 CFR
2014-04-01
... under the HUD building product standard and certification program for construction adhesives for wood... program for construction adhesives for wood floor systems. (a) Applicable standards. (1) All construction adhesives for field glued wood floor systems shall be designed, manufactured, and tested in compliance with...
The Development of Mutuality in Natural Small Groups.
ERIC Educational Resources Information Center
Baker, Paul Morgan
1983-01-01
Describes factors affecting the development of mutuality of attraction in natural small groups, and tests the hypothesis of the acquaintance process in 41 female residents of three floors of a university dormitory over the course of a year. Two floors showed definite increases in dyadic mutuality over time. (JAC)
Code of Federal Regulations, 2010 CFR
2010-04-01
... under the HUD building product standard and certification program for construction adhesives for wood... program for construction adhesives for wood floor systems. (a) Applicable standards. (1) All construction adhesives for field glued wood floor systems shall be designed, manufactured, and tested in compliance with...
Bangsgaard Bendtsen, Katja Maria; Krych, Lukasz; Sørensen, Dorte Bratbo; Pang, Wanyong; Nielsen, Dennis Sandris; Josefsen, Knud; Hansen, Lars H; Sørensen, Søren J; Hansen, Axel Kornerup
2012-01-01
Stress has profound influence on the gastro-intestinal tract, the immune system and the behavior of the animal. In this study, the correlation between gut microbiota composition determined by Denaturing Grade Gel Electrophoresis (DGGE) and tag-encoded 16S rRNA gene amplicon pyrosequencing (454/FLX) and behavior in the Tripletest (Elevated Plus Maze, Light/Dark Box, and Open Field combined), the Tail Suspension Test, and Burrowing in 28 female BALB/c mice exposed to two weeks of grid floor induced stress was investigated. Cytokine and glucose levels were measured at baseline, during and after exposure to grid floor. Stressing the mice clearly changed the cecal microbiota as determined by both DGGE and pyrosequencing. Odoribacter, Alistipes and an unclassified genus from the Coriobacteriaceae family increased significantly in the grid floor housed mice. Compared to baseline, the mice exposed to grid floor housing changed the amount of time spent in the Elevated Plus Maze, in the Light/Dark Box, and burrowing behavior. The grid floor housed mice had significantly longer immobility duration in the Tail Suspension Test and increased their number of immobility episodes from baseline. Significant correlations were found between GM composition and IL-1α, IFN-γ, closed arm entries of Elevated Plus Maze, total time in Elevated Plus Maze, time spent in Light/Dark Box, and time spent in the inner zone of the Open Field as well as total time in the Open Field. Significant correlations were found to the levels of Firmicutes, e.g. various species of Ruminococccaceae and Lachnospiraceae. No significant difference was found for the evaluated cytokines, except an overall decrease in levels from baseline to end. A significant lower level of blood glucose was found in the grid floor housed mice, whereas the HbA1c level was significantly higher. It is concluded that grid floor housing changes the GM composition, which seems to influence certain anxiety-related parameters.
ETR, TRA642. ON GROUND FLOOR. THE 60TON ETR REACTOR VESSEL ...
ETR, TRA-642. ON GROUND FLOOR. THE 60-TON ETR REACTOR VESSEL IS DROPPED INTO PLACE OVER PIT. KAISER USED TWO MULTI-BLOCK DRUM PULLEYS WITH A COMBINED CAPACITY OF 100 TONS AND A 100-TON DRUM HOIST. THE VESSEL WAS 35 1/2 FEET LONG. INL NEGATIVE NO. 56-4149. R.G. Larsen, Photographer, 12/18/1956 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Carbon dioxide and methane emissions from the scale model of open dairy lots.
Ding, Luyu; Cao, Wei; Shi, Zhengxiang; Li, Baoming; Wang, Chaoyuan; Zhang, Guoqiang; Kristensen, Simon
2016-07-01
To investigate the impacts of major factors on carbon loss via gaseous emissions, carbon dioxide (CO2) and methane (CH4) emissions from the ground of open dairy lots were tested by a scale model experiment at various air temperatures (15, 25, and 35 °C), surface velocities (0.4, 0.7, 1.0, and 1.2 m sec(-1)), and floor types (unpaved soil floor and brick-paved floor) in controlled laboratory conditions using the wind tunnel method. Generally, CO2 and CH4 emissions were significantly enhanced with the increase of air temperature and velocity (P < 0.05). Floor type had different effects on the CO2 and CH4 emissions, which were also affected by air temperature and soil characteristics of the floor. Although different patterns were observed on CH4 emission from the soil and brick floors at different air temperature-velocity combinations, statistical analysis showed no significant difference in CH4 emissions from different floors (P > 0.05). For CO2, similar emissions were found from the soil and brick floors at 15 and 25 °C, whereas higher rates were detected from the brick floor at 35 °C (P < 0.05). Results showed that CH4 emission from the scale model was exponentially related to CO2 flux, which might be helpful in CH4 emission estimation from manure management. Gaseous emissions from the open lots are largely dependent on outdoor climate, floor systems, and management practices, which are quite different from those indoors. This study assessed the effects of floor types and air velocities on CO2 and CH4 emissions from the open dairy lots at various temperatures by a wind tunnel. It provided some valuable information for decision-making and further studies on gaseous emissions from open lots.
Pelvic floor assessment after delivery: how should women be selected?
Soligo, Marco; Livio, Stefania; De Ponti, Elena; Scebba, Ileana; Carpentieri, Federica; Serati, Maurizio; Ferrazzi, Enrico
2016-11-01
Pelvic floor dysfunction after delivery is quite common. New mothers deserve to receive targeted care for pelvic floor dysfunction, but how should women who are at risk be identified and selected for treatment? This study investigated risk factors and puerperal health-seeking behaviours to develop a restrictive patient selection model for postpartum pelvic floor dysfunction assessment. This prospective observational study involved women who were at ≥32 weeks gestational age when they delivered in a tertiary referral maternity hospital in Milan, Italy, between July and December 2014. Eligible women were scheduled for a 3-month postnatal pelvic floor clinic. The adherence rate to the pelvic floor clinic and the prevalence of pelvic floor dysfunctions at 3 months postpartum were recorded. Univariable and logistic multivariable analyses were performed to select risk factors for pelvic floor dysfunctions. Risk factors were then tested for sensitivity and specificity for 3-month postpartum pelvic floor dysfunctions. Of 1606 eligible women, 1293 (80.5%) were included in the analysis; 685 puerperal women (53.0%) adhered to the 3-month postnatal pelvic floor clinic; pelvic floor dysfunctions were detected in 238 women (34.7%). Four elements emerged as risk factors: symptoms before pregnancy (OR 1.72, 95% CI 1.15-2.56; p=0.008), symptoms during pregnancy (OR 2.13, 95% CI 1.49-3.06; p<0.0001), vacuum extractor use (OR 1.62, 95% CI 1.04-2.54; p=0.034), and severe perineal tears (OR 19.45, 95% CI 2.42-156.15; p=0.005). The combined sensitivity and specificity for the 4 risk factors were 82% and 39%, respectively. Internal risk factors analysis offers the potential to efficiently restrict patient selection for follow-up. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Reliability and validity of a Turkish version of the Global Pelvic Floor Bother Questionnaire.
Doğan, Hanife; Özengin, Nuriye; Bakar, Yeşim; Duran, Bülent
2016-10-01
The aim of this study was to translate the Global Pelvic Floor Bother Questionnaire (GPFBQ) into Turkish and to assess its validity and reliability. The Turkish adaptation of the GPFBQ was created by following the stages of the intercultural adaptation process. A test-retest interval of 1 week was used to assess the reliability, which was examined by the intraclass correlation coefficient. The validity of the GPFBQ was assessed and compared with the Pelvic Floor Distress Inventory-20 (PFDI-20) and the Pelvic Floor Impact Questionnaire-7 (PFIQ-7) using Spearman's rank correlation coefficients. For construct validity, confirmatory factor analysis was performed. A total of 131 women, whose mean age was 46.83 years, were included in the study. The test-retest reliability of the GPFBQ was excellent (0.998, p < 0.0001). The GPFBQ correlated significantly with the PFDI-20 (r = 0.860, p = 0.00) and PFIQ-7 (r = 0.802, p = 0.00). Confirmatory factor analysis was performed to determine construct validity, and it was found that it had four dimensions. The Turkish version of the GPFBQ is a valid and reliable tool for assessing the symptoms of bother and severity in Turkish-speaking women with pelvic floor dysfunction.
Clinical knee findings in floor layers with focus on meniscal status.
Rytter, Søren; Jensen, Lilli Kirkeskov; Bonde, Jens Peter
2008-10-22
The aim of this study was to examine the prevalence of self-reported and clinical knee morbidity among floor layers compared to a group of graphic designers, with special attention to meniscal status. We obtained information about knee complaints by questionnaire and conducted a bilateral clinical and radiographic knee examination in 134 male floor layers and 120 male graphic designers. After the exclusion of subjects with reports of earlier knee injuries the odds ratio (OR) with 95% confidence intervals (CI) of knee complaints and clinical findings were computed among floor layers compared to graphic designers, using logistic regression. Estimates were adjusted for effects of body mass index, age and knee straining sports. Using radiographic evaluations, we conducted side-specific sensitivity analyses regarding clinical signs of meniscal lesions after the exclusion of participants with tibiofemoral (TF) osteoarthritis (OA). Reports of knee pain (OR = 2.7, 95% CI = 1.5-4.6), pain during stair walking (OR = 2.2, 95% CI = 1.3-3.9) and symptoms of catching of the knee joint (OR = 2.9, 95% CI = 1.4-5.7) were more prevalent among floor layers compared to graphic designers. Additionally, significant more floor layers than graphic designers had clinical signs suggesting possible meniscal lesions: a positive McMurray test (OR = 2.4, 95% CI = 1.1-5.0) and TF joint line tenderness (OR = 5.4, 95% CI = 2.4-12.0). Excluding floor layers (n = 22) and graphic designers (n = 15) with radiographic TF OA did not alter this trend between the two study groups: a positive McMurray test (OR = 2.2, 95% CI = 1.0-4.9), TF joint line tenderness (OR = 5.0, 95% CI = 2.0-12.5). Results indicate that floor layers have a high prevalence of both self-reported and clinical knee morbidity. Clinical knee findings suggesting possible meniscal lesions were significant more prevalent among floor layers compared to a group of low-level exposed graphic designers and an association with occupational kneeling could be possible. However, causality cannot be confirmed due to the cross-sectional study design.
How do cattle respond to sloped floors? An investigation using behavior and electromyograms.
Rajapaksha, E; Tucker, C B
2014-05-01
On dairy farms, flooring is often sloped to facilitate drainage. Sloped floors have been identified as a possible risk factor for lameness, but relatively little is known about how this flooring feature affects dairy cattle. Ours is the first study to evaluate the short-term effects of floor slope on skeletal muscle activity, restless behavior (measured by number of steps), and latency to lie down after 90 min of standing. Sixteen Holstein cows were exposed to floors with a 0, 3, 6, or 9% slope in a crossover design, with a minimum of 45 h between each testing session. Electromyograms were used to evaluate the activity of middle gluteal and biceps femoris muscles. Muscle activity was evaluated in 2 contexts: (1) static muscle contractions when cows continuously transferred weight to each hind leg, before and after 90 min of standing; and (2) dynamic contractions that occurred during 90 min of treatment exposure. Median power frequency and median amplitude of both static and dynamic muscle electrical signals were calculated. Total muscle activity was calculated using the root mean square of the signals. Restless behavior, the number of steps per treatment, steps and kicks in the milking parlor, and the latency to lie down after the test sessions were also measured. It was predicted that restless behavior, muscle fatigue (as measured by median power frequency and median amplitude), total muscle activity, and latency to lie down after testing would increase with floor slope. However, no treatment differences were found. Median power frequency was significantly greater for the middle gluteal muscle [35 ± 4 Hz (mean and SE)] compared with the biceps femoris muscle (24 ± 3 Hz), indicating that the contractive properties of these muscles differ. The number of steps per minute and total muscle activity increased significantly over 90 min of standing, irrespective of floor slope. Although restless behavior and muscle function did not change with slope in our study, this work demonstrates that electromyograms can be used to measure skeletal leg muscle activity in cattle. This technology, along with restless behavior, could be useful in assessing cow comfort in other situations, such as prolonged standing. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harvey, Scott D.; He, Lijian; Wahl, Jon H.
2012-08-30
This study provides a preliminary evaluation of the Field and Laboratory Emission Cell (FLEC) for its suitability for sampling building materials for toxic compounds and their associated impurities and residues that might remain after a terrorist chemical attack. Chemical warfare (CW) agents and toxic industrial chemicals were represented by a range of test probes that included CW surrogates. The test probes encompassed the acid-base properties, volatilities, and polarities of the expected chemical agents and residual compounds. Results indicated that dissipation of the test probes depended heavily on the underlying material. Near complete dissipation of almost all test probes occurred frommore » galvanized stainless steel within 3.0 hrs, whereas far stronger retention with concomitant slower release was observed for vinyl composition floor tiles. The test probes displayed immediated permanence on Teflon. FLEC sampling was further evaluated by profiling residues remaining after the evaporation of 2-chloroethyl ethyl sulfide, a sulfur mustard simulant. This study lays the groundwork for the eventual goal of applying this sampling approach for collection of forensic attribution signatures that remain after a terrorist chemical attack.« less
Spontaneous remission of a squamous cell carcinoma of the floor of the mouth.
de Andrade Sousa, Alexandre; Lopes Rena, Rafael; Souza Silva, Guilherme; Marcos Arantes Soares, João; Porcaro-Salles, José Maria; Nunes, Laiz; Alves Mesquita, Ricardo; Jham, Bruno Correia
2014-10-01
Spontaneous remission is a rare, but well recognized event in oncology. Certain tumours, such as melanomas, hypernephromas and neuroblastomas, are known for showing spontaneous regression. Similarly, spontaneous regression of oral lymphomas, as well as oropharyngeal and recurrent tongue carcinomas, has been reported. Here, we present a novel case of a patient with a primary squamous cell carcinoma on the floor of the mouth whose tumour regressed spontaneously in three months, without any treatment. We also review of the literature on the spontaneous remission of oral cancer and discuss possible mechanisms for this phenomenon. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Long-term (6-wk) hindlimb suspension inhibits spermatogenesis in adult male rats
NASA Technical Reports Server (NTRS)
Tash, Joseph S.; Johnson, Donald C.; Enders, George C.
2002-01-01
The International Space Station will allow extended habitation in space and long-term exposure to microgravity (microG). A concern is the impact of long-term microG exposure on the ability of species to reproduce. The model often used to simulate microG is rat hindlimb suspension (HLS), where the hindlimbs are elevated above the cage floor with a tail harness. Experiments described here are the first to examine the effect of long-term HLS on testicular function in adult male rats. Free-roaming (controls), animals with only the tail harnessed but hindlimbs in contact with the cage floor (TO), and HLS animals were tested for 6 wk. Cryptorchidism was prevented in TO and HLS animals by partial constriction of the inguinal canal with sutures. All parameters were compared at the end of the 6-wk experiment. Testicular weights and spermatogenesis were significantly reduced by HLS, such that no spermatogenic cells beyond round spermatids were present and epididymides were devoid of mature sperm. In many tubules, loss of all germ cells, except a few spermatogonia, resulting in histopathology similar to the Sertoli cell, was observed. Spermatogenesis appeared unaffected in control and TO animals. Sertoli and Leydig cell appearance, testosterone, luteinizing hormone, and follicle-stimulating hormone levels, and epididymal and seminal vesicle weight were unchanged by HLS. Cortisone was not elevated by HLS; thus stress may not be a factor. These results demonstrate that spermatogenesis is severely inhibited by long-term HLS, whereas testicular androgen production is not. These results have significant implications regarding serious effects of long-term exposure to microG on the reproductive capability of scrotal mammals, including humans.
Investigation of dairy cattle ease of movement on new methyl methacrylate resin aggregate floorings.
Franco-Gendron, N; Bergeron, R; Curilla, W; Conte, S; DeVries, T; Vasseur, E
2016-10-01
Freestall dairy farms commonly present issues with cattle slips and falls caused by smooth flooring and manure slurry. This study examined the effect of 4 new methyl methacrylate (MMA) resin aggregate flooring types (1-4) compared with rubber (positive) and concrete (negative control) on dairy cow (n=18) ease of movement when walking on straight and right-angled corridors. Our hypothesis was that cow ease of movement when walking on the MMA surfaces would be better than when walking on traction milled concrete, and at least as good as when walking on rubber. Cattle ease of movement was measured using kinematics, accelerometers, and visual observation of gait and associated behaviors. Stride length, swing time, stance time, and hoof height were obtained from kinematic evaluation. Acceleration and asymmetry of variance were measured with accelerometers. Locomotion score and behaviors associated with lameness, such as arch back, head bob, tracking up, step asymmetry, and reluctance to bear weight were visually observed. Stride length, swing time, stance time, and the number of steps taken were the only variables affected by flooring type. Differences between flooring types for these variables were tested using a generalized linear mixed model with cow as a random effect, week as a random block factor, and flooring type as a fixed effect. Multiple comparisons with a Scheffé adjustment were done to analyze differences among flooring types. Stride length was 0.14 m longer (better) on rubber when compared with concrete, and 0.11 and 0.17 m shorter on MMA 1 and 2 compared with rubber. On MMA 3 and 4, stride length did not differ from either rubber or concrete. Swing time was 0.04 s shorter (worse) on MMA 1 than on rubber, but did not differ from any other flooring. Stance time was 0.18 s longer (worse) on MMA 2 when compared with rubber, but it did not differ from any other treatment. The number of steps was higher on MMA 4 compared with rubber (4.57 vs. 3.95 steps), but did not differ from any other treatment. Of all the MMA floors tested, MMA 3 was the only one that was consistently as good as rubber (positive control). All 4 MMA floors never differed from concrete (negative control) in any of the ease of movement variables measured. These results suggest that MMA 3 may improve cow ease of movement, compared with the other MMA floors, but more research is required to confirm these findings. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
MTR, TRA603. FIRST FLOOR PLAN. REACTOR AT CENTER. TWENTYMETER CHOPPER ...
MTR, TRA-603. FIRST FLOOR PLAN. REACTOR AT CENTER. TWENTY-METER CHOPPER HOUSE. COFFIN TURNING ROLLS. REMOVABLE PANEL OVER CANAL ON EAST SIDE. NEW PLUG STORAGE ACCESS. DOOR SCHEDULE INDICATES STEEL (FOR VAULT), WIRE MESH, AND HOLLOW METAL TYPES. STORAGE AND ISSUE ROOM. SAFETY SHOWERS. DOORWAY TO WING, TRA-604. BLAW-KNOX 3150-803-2, 7/1950. INL INDEX NO. 531-0603-00-098-100561, REV. 10. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
A&M. TAN607 first floor plan for cold assembly area. Shows ...
A&M. TAN-607 first floor plan for cold assembly area. Shows special source vaults, X-ray room, instrument shops, and positions of large machines in component test laboratory. This drawing was re-drawn to show conditions in 1994. Ralph M. Parsons 902-3-ANP-607-A 100. Date of original: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 034-060-00-693-106752 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
38. INTERIOR VIEW TO THE NORTHWEST OF THE SECOND FLOOR ...
38. INTERIOR VIEW TO THE NORTHWEST OF THE SECOND FLOOR CORRIDOR ON THE SOUTH SIDE OF THE DISASSEMBLY BAY. VIEWING AND WORK STATIONS ARE ALONG THE NORTH WALL OF THE CORRIDOR. - Nevada Test Site, Reactor Maintenance Assembly & Dissassembly Facility, Area 25, Jackass Flats, Junction of Roads F & G, Mercury, Nye County, NV
LPT. EBOR (TAN646). Floor plan for new helium management wing. ...
LPT. EBOR (TAN-646). Floor plan for new helium management wing. Detail of sample vault and basement switch room. Kaiser engineers EBOR/GA-646-A-101. Date: May 1963. INEEL index code no. 037-0646-00-486-119115 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
ADM. Service Building (TAN603). Floor plan. Names of functional areas. ...
ADM. Service Building (TAN-603). Floor plan. Names of functional areas. Ralph M. Parsons 902-2-ANY-603-A 43. Date: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 033-0603-00-693-106718 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
ADM. Change House (TAN606). Elevations and floor plan. Room Names. ...
ADM. Change House (TAN-606). Elevations and floor plan. Room Names. Ralph M. Parsons 902-2-ANP-606-A 65. Date: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 035-0606-00-693-106733 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
ADM. Warehouse (TAN604) Floor plan. General warehouse and chemical storage. ...
ADM. Warehouse (TAN-604) Floor plan. General warehouse and chemical storage. Ralph M. Parsons 902-2-ANP-604-A 55. Date: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 035-0604-00-693-106727 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
LOFT. Containment and service building (TAN650) basement floor plan. Basement ...
LOFT. Containment and service building (TAN-650) basement floor plan. Basement airlock, shielded roadway, service areas, connection to control building. Kaiser engineers 6413-11-STEP/LOFT-650-A-1. Date: October 1964. INEEL index code no. 036-650-00-416-122213 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
A&M. Technical service laboratory in administration building (TAN602). Floor plan, ...
A&M. Technical service laboratory in administration building (TAN-602). Floor plan, reception desk, door and finish schedules. Ralph M. Parsons 1480-12-ANP/GE-3-602-A-1. INEEL index code no. 033-0602-00-693-107488 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
36. AS BUILT DRAWING OF TAN 629 HANGAR SHOWING FLOOR ...
36. AS BUILT DRAWING OF TAN 629 HANGAR SHOWING FLOOR PLAN AND VICINITY PLAN RELATIONSHIP TO ADMINISTRATION AND MAINTENANCE AREA. RALPH M. PARSONS DRAWING NUMBER: 1229-2 ANP/GE 5-629-A-2. DATED MARCH 15, 1957. - Idaho National Engineering Laboratory, Test Area North, Hangar No. 629, Scoville, Butte County, ID
Spring tube braces for seismic isolation of buildings
NASA Astrophysics Data System (ADS)
Karayel, V.; Yuksel, Ercan; Gokce, T.; Sahin, F.
2017-01-01
A new low-cost seismic isolation system based on spring tube bracings has been proposed and studied at the Structural and Earthquake Engineering Laboratory of Istanbul Technical University. Multiple compression-type springs are positioned in a special cylindrical tube to obtain a symmetrical response in tension and compression-type axial loading. An isolation floor, which consists of pin-ended steel columns and spring tube bracings, is constructed at the foundation level or any intermediate level of the building. An experimental campaign with three stages was completed to evaluate the capability of the system. First, the behavior of the spring tubes subjected to axial displacement reversals with varying frequencies was determined. In the second phase, the isolation floor was assessed in the quasi-static tests. Finally, a ¼ scaled 3D steel frame was tested on the shake table using actual acceleration records. The transmitted acceleration to the floor levels is greatly diminished because of the isolation story, which effects longer period and higher damping. There are no stability and self-centering problems in the isolation floor.
Ortega, Gil R; Taksali, Sudeep; Smart, Ryan; Baumgaertner, Michael R
2009-01-01
Cellular phone use within the hospital setting has increased as physicians, nurses, and ancillary staff incorporate wireless technologies in improving efficiencies, cost, and maintaining patient safety and high quality healthcare [11]. Through the use of wireless, cellular communication, an overall improvement in communication accuracy and efficiency between intraoperative orthopaedic surgeons and floor nurses may be achieved. Both communication types occurred while the surgeon was scrubbed in the operating room (OR). Indirect communication occurred when the pager call was answered by the OR circulating nurse with communication between the surgeon, circulating nurse, and floor nurse. Direct communication consisted of cell phone and Jabra Bluetooth BT200 wireless ear piece used by the surgeon. The surgeon answered the floor nurse's cellular call by phone ring-activated automatic answering. The study was conducted during scheduled orthopaedic procedures. An independent observer measured time variables with a stop-watch while orthopaedic nurses randomly called via pager or cell phone. The nurses asked for patient caregiver confirmation and answers to 30 different patient-care questions. Sixty trials were performed with 30 cell and 30 page communications. Direct cellular communication showed a better response rate than indirect page (Cell 100%, Page 73%). Indirect page communication allowed a 27% and 33% error rate with patient problem and surgeon solution communications, respectively. There were no reported communication errors while using direct wireless, cellular communication. When compared to page communications, cellular communications showed statistically significant improvements in mean time intervals in response time (Cell = 11s, Page = 211s), correct patient identification (Cell = 5s, Page = 172s), patient problem and solution time (Cell = 13s, Page = 189s), and total communication time (Cell = 32s, Page = 250s) (s = seconds, all P < 0.001). Floor nurse satisfaction ratings (dependent on communication times and/or difficulties) were improved with direct cellular communication (Cell = 29 excellent, Page = 11 excellent). Intraoperative case interruptions (defined as delaying surgical progress) were more frequent with indirect page communication (10 page v. 0 cell). Our study demonstrates that direct wireless communication may be used to improve intraoperative communication and enhance patient safety. Direct wireless, cellular intraoperative communication improves communication times, communication accuracy, communication satisfaction, and minimizes intraoperative case interruption. As a result of this study, we hope to maintain our transition to direct wireless, cellular intraoperative orthopaedic communication to reduce medical errors, improve patient care, and enhance both orthopaedic surgeon and nursing efficiencies.
Callahan, S R; Cross, A J; DeDecker, A E; Lindemann, M D; Estienne, M J
2017-01-01
The objective was to determine effects of nursery group-size-floor space allowance on growth, physiology, and hematology of replacement gilts. A 3 × 3 factorial arrangement of treatments was used wherein gilts classified as large, medium, or small ( = 2537; BW = 5.6 ± 0.6 kg) from 13 groups of weaned pigs were placed in pens of 14, 11, or 8 pigs resulting in floor space allowances of 0.15, 0.19, or 0.27 m/pig, respectively. Pigs were weighed on d 0 (weaning) and d 46 (exit from nursery). The ADG was affected by group-size-floor space allowance × pig size ( = 0.04). Large- and medium-size gilts allowed the most floor space had greater ( < 0.05) ADG than similar size gilts allowed the least floor space but for small size gilts there was no effect ( > 0.05) of group size-floor space allowance. Mortality in the nursery was not affected ( > 0.05) by treatment, size, or treatment × size and overall was approximately 2.1%. Complete blood counts and blood chemistry analyses were performed on samples collected at d 6 and 43 from a subsample of gilts ( = 18/group-size-floor space allowance) within a single group. The concentration ( < 0.01) and percentage ( = 0.03) of reticulocytes was the least and red blood cell distribution width the greatest ( < 0.01) in gilts allowed 0.15 m floor space (effects of treatment). Blood calcium was affected by treatment ( = 0.02) and concentrations for gilts allowed the greatest and intermediate amounts of floor space were greater ( < 0.05) than for gilts allowed the least floor space. Serum concentrations of cortisol were not affected by treatment × day ( = 0.27). Cortisol concentrations increased from d 6 to d 43 in all groups and were affected by day ( < 0.01) but not treatment ( = 0.53). Greater space allowance achieved by placing fewer pigs per pen in the nursery affected blood parameters and resulted in large- and medium-size replacement gilts displaying increased ADG. Further study will determine if these effects influence lifetime reproductive capacity and sow longevity.
Ozdemir, Filiz Ciledag; Pehlivan, Erkan; Melekoglu, Rauf
2017-01-01
To investigate the pelvic floor muscle strength of the women andevaluateits possible correlation with sexual dysfunction. In this cross-sectional type study, stratified clusters were used for the sampling method. Index of Female Sexual Function (IFSF) worksheetwere used for questions on sexual function. The pelvic floor muscle strength of subjects was assessed byperineometer. The chi-squared test, logistic regression and Pearson's correlation analysis were used for the statistical analysis. Four hundred thirty primiparous women, mean age 38.5 participated in this study. The average pelvic floor muscle strength value was found 31.4±9.6 cm H 2 O and the average Index of Female Sexual Function (IFSF) score was found 26.5±6.9. Parity (odds ratio OR=5.546) and age 40 or higher (OR=3.484) were found correlated with pelvic floor muscle weakness (p<0.05). The factors directly correlated with sexual dysfunction were found being overweight (OR=2.105) and age 40 or higher (OR=2.451) (p<0.05). Pearson's correlation analysis showed that there was a statistically significantlinear correlation between the muscular strength of the pelvic floor and sexual function (p=0.001). The results suggested subjects with decreased pelvic floor muscle strength value had higher frequency of sexual dysfunction.
40 CFR Table 7 to Subpart IIIii of... - Required Elements of Washdown Plans
Code of Federal Regulations, 2012 CFR
2012-07-01
... baskets 6. Hydrogen system piping 7. Basement floor of cell rooms 8. Tanks 9. Pillars and beams in cell... Mercury Cell Chlor-Alkali Plants Pt. 63, Subpt. IIIII, Table 7 Table 7 to Subpart IIIII of Part 63... following as part of your plan . . . 1. Center aisles of cell rooms A description of the manner of washdown...
40 CFR Table 7 to Subpart IIIii of... - Required Elements of Washdown Plans
Code of Federal Regulations, 2011 CFR
2011-07-01
... baskets 6. Hydrogen system piping 7. Basement floor of cell rooms 8. Tanks 9. Pillars and beams in cell... Mercury Cell Chlor-Alkali Plants Pt. 63, Subpt. IIIII, Table 7 Table 7 to Subpart IIIII of Part 63... following as part of your plan . . . 1. Center aisles of cell rooms A description of the manner of washdown...
40 CFR Table 7 to Subpart IIIii of... - Required Elements of Washdown Plans
Code of Federal Regulations, 2010 CFR
2010-07-01
... Mercury Cell Chlor-Alkali Plants Pt. 63, Subpt. IIIII, Table 7 Table 7 to Subpart IIIII of Part 63... following as part of your plan . . . 1. Center aisles of cell rooms A description of the manner of washdown... baskets 6. Hydrogen system piping 7. Basement floor of cell rooms 8. Tanks 9. Pillars and beams in cell...
40 CFR Table 7 to Subpart IIIii of... - Required Elements of Washdown Plans
Code of Federal Regulations, 2013 CFR
2013-07-01
... Mercury Cell Chlor-Alkali Plants Pt. 63, Subpt. IIIII, Table 7 Table 7 to Subpart IIIII of Part 63... following as part of your plan . . . 1. Center aisles of cell rooms A description of the manner of washdown... baskets 6. Hydrogen system piping 7. Basement floor of cell rooms 8. Tanks 9. Pillars and beams in cell...
40 CFR Table 7 to Subpart IIIii of... - Required Elements of Washdown Plans
Code of Federal Regulations, 2014 CFR
2014-07-01
... Mercury Cell Chlor-Alkali Plants Pt. 63, Subpt. IIIII, Table 7 Table 7 to Subpart IIIII of Part 63... following as part of your plan . . . 1. Center aisles of cell rooms A description of the manner of washdown... baskets 6. Hydrogen system piping 7. Basement floor of cell rooms 8. Tanks 9. Pillars and beams in cell...
Discharge properties of hippocampal neurons during performance of a jump avoidance task
Lenck-Santini, Pierre-Pascal; Fenton, André A.; Muller, Robert U.
2008-01-01
We recorded single hippocampal cells while rats performed a jump avoidance task. In this task, a rat was dropped onto the metal floor of a 33 cm gray wooden cube and was given a mild electric shock if it did not jump up onto the box rim in less than 15 sec. We found that many hippocampal pyramidal cells and most interneurons discharged preferentially at either the drop, the jump or on both events. By simultaneously recording the hippocampal EEG, we found that the discharge of most of the event-related pyramidal cells was modulated by the theta rhythm and moreover that discharge precessed with theta cycles in the same fashion seen for pyramidal cells in their role as place cells. The elevations of firing rate at drop and jump were accompanied by increases in theta frequency. We conclude that many of the features of event-related discharge can be interpreted as being equivalent to the activity of place cells with firing fields above the box floor. Nevertheless, there are sufficient differences between expectations from place cells and observed activity to indicate that pyramidal cells may be able to signal events as well as location. PMID:18596153
Exceptionally well-preserved Cretaceous microfossils reveal new biomineralization styles.
Wendler, Jens E; Bown, Paul
2013-01-01
Calcareous microplankton shells form the dominant components of ancient and modern pelagic sea-floor carbonates and are widely used in palaeoenvironmental reconstructions. The efficacy of these applications, however, is dependent upon minimal geochemical alteration during diagenesis, but these modifying processes are poorly understood. Here we report on new biomineralization architectures of previously unsuspected complexity in calcareous cell-wall coverings of extinct dinoflagellates (pithonellids) from a Tanzanian microfossil-lagerstätte. These Cretaceous 'calcispheres' have previously been considered biomineralogically unremarkable but our new observations show that the true nature of these tests has been masked by recrystallization. The pristine Tanzanian fossils are formed from fibre-like crystallites and show archeopyles and exquisitely constructed opercula, demonstrating the dinoflagellate affinity of pithonellids, which has long been uncertain. The interwoven fibre-like structures provide strength and flexibility enhancing the protective function of these tests. The low-density wall fabrics may represent specific adaptation for oceanic encystment life cycles, preventing the cells from rapid sinking.
Kim, Sumin
2009-01-01
The objective of this research was to develop environment-friendly adhesives for face fancy veneer bonding of engineered flooring using the natural tannin form bark in the wood. The natural wattle tannin adhesive were used to replace UF resin in the formaldehyde-based resin system in order to reduce formaldehyde and volatile organic compound (VOC) emissions from the adhesives used between plywoods and fancy veneers. PVAc was added to the natural tannin adhesive to increase viscosity of tannin adhesive for surface bonding. For tannin/PVAc hybrid adhesives, 5%, 10%, 20% and 30% of PVAc to the natural tannin adhesives were added. tannin/PVAc hybrid adhesives showed better bonding than the commercial natural tannin adhesive with a higher level of wood penetration. The initial adhesion strength was sufficient to be maintained within the optimum initial tack range. The standard formaldehyde emission test (desiccator method), field and laboratory emission cell (FLEC) and VOC analyzer were used to determine the formaldehyde and VOC emissions from engineered flooring bonded with commercial the natural tannin adhesive and tannin/PVAc hybrid adhesives. By desiccator method and FLEC, the formaldehyde emission level of each adhesive showed the similar tendency. All adhesives satisfied the E(1) grade (below 1.5 mg/L) and E(0) grade (below 0.5 mg/L) with UV coating. VOC emission results by FLEC and VOC analyzer were different with the formaldehyde emission results. TVOC emission was slightly increased as adding PVAc.
Wang, W Y; Chang, J J
1997-08-01
In the present study, we hypothesized that the enhancements obtained from the practice of jumping activity could be transferred to improve the walking balance in children with mental retardation (MR) and Down's syndrome (DS). Fourteen children with the diagnosis of MR or DS, aged 3 to 6 years, were recruited from a day care institution. They were ambulant but without jumping ability. Sixty-one non-handicapped children was used to serve as a normative comparison group. Before the training program, the performances of walking balance, jump skills and jumping distances were assessed individually by one physical therapist. The balance sub-test in the Bruininks Oseretsky Test of Motor Proficiency (BOTMP) was administered to assess the walking balance. Motor Skill Inventory (MSI) was used to assess the qualitative levels of jumping skills. A jumping skill training lesson that included horizontal jumps and vertical jumps was designed and integrated into the educational program. The recruited children received 3 sessions of training per-week for 6 weeks. A post-training test and a follow-up test were administered to the handicapped children. In BOTMP scores, statistical differences exited between the pre-training and post-training tests in the tested items of floor walk and beam walk. However, no significant difference was found in the items of floor stand, beam stand and floor heel-toe walk. MSI scales revealed there were significant differences between pre-training and post-training tests. There was no significant difference between the scores of post-training test and the follow-up test. The results implicated that the jumping activity might effectively evoke the automatic and dynamic postural control. Moreover, the significant improvements of the floor walk and beam walk performances might be due to the transferred effects via the practice of dynamic jumping activity. Furthermore, implications and suggestions are discussed.
Oblasser, Claudia; McCourt, Christine; Hanzal, Engelbert; Christie, Janice
2016-04-01
This paper presents a feasibility trial protocol the purpose of which is to prepare for a future randomised controlled trial to determine the effectiveness of vibrating vaginal pelvic floor training balls for postpartum pelvic floor muscle rehabilitation. Vibrating vaginal pelvic floor training balls are available in Austria to enhance women's pelvic floor muscles and thus prevent or treat urinary incontinence and other pelvic floor problems following childbirth. Nonetheless, there is currently little empirical knowledge to substantiate their use or assess their relative effectiveness in comparison to current standard care, which involves pelvic floor muscle exercises. Single blind, randomised controlled feasibility trial with two parallel groups. It is planned to recruit 56 postpartum women in Vienna, who will be randomised into one of two intervention groups to use either vibrating vaginal balls or a comparator pelvic floor muscle exercises for 12 weeks. As this is a feasibility study, study design features (recruitment, selection, randomisation, intervention concordance, data collection methods and tools) will be assessed and participants' views and experiences will be surveyed. Tested outcome measures, collected before and after the intervention, will be pelvic floor muscle performance as reported by participants and measured by perineometry. Descriptive and inferential statistics and content analysis will serve the preparation of the future trial. The results of this feasibility trial will inform the design and conduct of a full randomised controlled trial and provide insight into the experiences of women regarding the interventions and study participation. © 2015 John Wiley & Sons Ltd.
Liu, Baoyan; Wang, Yang; Xu, Huanfang; Chen, Yuelai; Wu, Jiani; Mo, Qian; Liu, Zhishun
2014-08-15
In women with mixed urinary incontinence, pelvic floor muscle training and solifenacin is the recommended conservative treatment, while electroacupuncture is a safe, economical and effective option. In this prospective, multi-center, randomized controlled trial, five hundred women with mixed urinary incontinence, from 10 centers will be randomized to receive either electroacupuncture or pelvic floor muscle training plus solifenacin. Women in the acupuncture group will receive electroacupuncture for 3 sessions per week, over 12 weeks, while women in the control group will receive pelvic floor muscle training plus solifenacin (5 mg once daily) for 36 weeks. The primary outcome measure is the proportion of change in 72-hour incontinence episode frequency from baseline to week 12. The secondary outcome measures include eleven items, including proportion of participants with ≥50% decrease in average 72-h incontinence episode frequency, change from baseline in the amount of urine leakage and proportion of change from baseline in 72-h incontinence episode frequency in week 25-36, and so forth. Statistical analysis will include covariance analysis, nonparametric tests and t tests. The objective of this trial is to compare the efficacy and safety of electroacupuncture versus pelvic floor muscle training plus solifenacin in women with moderate and severe mixed urinary incontinence. ClinicalTrials.gov Identifier: NCT02047032.
The floor effect: impoverished spatial memory for elevator buttons.
Vendetti, Michael; Castel, Alan D; Holyoak, Keith J
2013-05-01
People typically remember objects to which they have frequently been exposed, suggesting that memory is a by-product of perception. However, prior research has shown that people have exceptionally poor memory for the features of some objects (e.g., coins) to which they have been exposed over the course of many years. Here, we examined how people remember the spatial layout of the buttons on a frequently used elevator panel, to determine whether physical interaction (rather than simple exposure) would ensure the incidental encoding of spatial information. Participants who worked in an eight-story office building displayed very poor recall for the elevator panel but above-chance performance on a recognition test. Performance was related to how often and how recently the person had used the elevator. In contrast to their poor memory for the spatial layout of the elevator buttons, most people readily recalled small distinctive graffiti on the elevator walls. In a more implicit test, the majority were able to locate their office floor and the eighth floor button when asked to point toward these buttons when in the actual elevator, with the button labels covered. However, identification was very poor for other floors (including the first floor), suggesting that even frequent interaction with information does not always lead to accurate spatial memory. These findings have implications for understanding the complex relationships among attention, expertise, and memory.
Miyamoto, Shinji; Shinmyouzu, Kouhei; Miyamoto, Ikuya; Takeshita, Kenji; Terada, Toshihisa; Takahashi, Tetsu
2013-08-01
This study utilized the constitution and expression of Runx2/Cbfa1 to conduct 6-month-post-operation histomorphometrical and histochemical analysis of osteocalcin in bone regeneration following sinus-floor augmentation procedures using β-tricalcium phosphate (β-TCP) and autogenous cortical bone. Thirteen sinuses of nine patients were treated with sinus-floor augmentation using 50% β-TCP and 50% autogenous cancellous bone harvested from the ramus of the mandible. Biopsies of augmented sinuses were taken at 6 months for histomorphometric and immunohistochemical measurements. Runx2/Cbfa1- and osteocalcin-positive cells were found around TCP particles and on the bone surface. Approximately 60% of cells found around TCP particles stained positive for Runx2/Cbfa1. Fewer cells stained positive for osteocalcin. These positive cells decreased apically with increasing vertical distance from the maxillary bone surface. Histomorphometric analysis showed that the augmented site close to residual bone and periosteum contained approximately 42% bony tissue and 42% soft connective tissue, and the remaining 16% consisted of TCP particles. On the other hand, the augmented bone far from residual bone and periosteum contained 35% bony tissue and 50% soft connective tissue. Our data suggest that TCP particles attract osteoprogenitor cells that migrate into the interconnecting micropores of the bone-substitute material by 6 months. The augmented site close to residual bone contained a higher proportion of bony tissue and a lower proportion of soft connective tissue than did the augmented site far from residual bone. © 2012 John Wiley & Sons A/S.
12. BUILDING 621, INTERIOR, GROUND FLOOR, LOOKING NORTHWEST AT SCREENING ...
12. BUILDING 621, INTERIOR, GROUND FLOOR, LOOKING NORTHWEST AT SCREENING MACHINE THAT REMOVES SHELL FRAGMENTS. METALLIC DUST REMOVED BY MAGNETIC SEPERATOR UNDERNEATH SCREEN. SAWDUST IS RETURNED TO SAWDUST HOPPER BY ELEVATOR. HOODS OVER SCREENING MACHINE AT WORKBENCH REMOVE FINE SAWDUST. - Picatinny Arsenal, 600 Area, Test Areas District, State Route 15 near I-80, Dover, Morris County, NJ
LPT. Guard House (TAN642). Elevations, floor plan, sections, details. Ralph ...
LPT. Guard House (TAN-642). Elevations, floor plan, sections, details. Ralph M. Parsons 1229-12 ANP/GE-7-642-A-S-H7V-1. November 1956. Approved by INEEL Classification Office for public release. INEEL index code no. 038-0642-00-693-107306 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
A&M. Demineralization plant, TAN649. Floor plan, elevation details. Ralph M. ...
A&M. Demineralization plant, TAN-649. Floor plan, elevation details. Ralph M. Parsons 1480-4-ANP/GE-3-649-A-1. Date: October 1958. Approved by INEEL Classification Office for public release. INEEL index code no. 034-0649-00-693-107439 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
IET. Control and equipment building (TAN620) floor plan. Schedule of ...
IET. Control and equipment building (TAN-620) floor plan. Schedule of furniture and equipment. Ralph M. Parsons 902-4-ANP-A 320. Date: February 1954. Approved by INEEL Classification Office for public release. INEEL index code no. 035-0620-00-693-106905 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paul Higley; J. Robert Woolsey; Ralph Goodman
A Consortium, designed to assemble leaders in gas hydrates research, has been established at the University of Mississippi's Center for Marine Resources and Environmental Technology, CMRET. The primary objective of the group is to design and emplace a remote monitoring station on the sea floor in the northern Gulf of Mexico by the year 2005, in an area where gas hydrates are known to be present at, or just below, the sea floor. This mission necessitates assembling a station that will monitor physical and chemical parameters of the sea water and sea floor sediments on a more-or-less continuous basis overmore » an extended period of time. Development of the station allows for the possibility of expanding its capabilities to include biological monitoring, as a means of assessing environmental health. Establishment of the Consortium has succeeded in fulfilling the critical need to coordinate activities, avoid redundancies and communicate effectively among researchers in this relatively new research arena. Complementary expertise, both scientific and technical, has been assembled to promote innovative research methods and construct necessary instrumentation. Noteworthy achievements one year into the extended life of this cooperative agreement include: (1) Progress on the vertical line array (VLA) of sensors: (1a) Repair attempts of the VLA cable damaged in the October >1000m water depth deployment failed; a new design has been tested successfully. (1b) The acoustic modem damaged in the October deployment was repaired successfully. (1c) Additional acoustic modems with greater depth rating and the appropriate surface communications units have been purchased. (1d) The VLA computer system is being modified for real time communications to the surface vessel using radio telemetry and fiber optic cable. (1e) Positioning sensors--including compass and tilt sensors--were completed and tested. (1f) One of the VLAs has been redesigned to collect near sea floor geochemical data. (2) Progress on the Sea Floor Probe: (2a) With the Consortium's decision to divorce its activities from those of the Joint Industries Program (JIP), due to the JIP's selection of a site in 1300m of water, the Sea Floor Probe (SFP) system was revived as a means to emplace arrays in the shallow subsurface until arrangements can be made for boreholes at >1000m water depth. (2b) The SFP penetrometer has been designed and construction begun. (2c) The SFP geophysical and pore-fluid probes have been designed. (3) Progress on the Acoustic Systems for Monitoring Gas Hydrates: (3a) Video recordings of bubbles emitted from a seep in Mississippi Canyon have been analyzed for effects of currents and temperature changes. (3b) Several acoustic monitoring system concepts have been evaluated for their appropriateness to MC118, i.e., on the deep sea floor. (3c) A mock-up system was built but was rejected as too impractical for deployment on the sea floor. (4) Progress on the Electromagnetic Bubble Detector and Counter: (4a) Laboratory tests were performed using bubbles of different sizes in waters of different salinities to test the sensitivity of the. Differences were detected satisfactorily. (4b) The system was field tested, first at the dock and then at the shallow water test site at Cape Lookout Bight where methane bubbles from the sea floor, naturally, in 10m water depth. The system successfully detected peaks in bubbling as spike decreases in conductivity. (5) Progress on the Mid-Infrared Sensor for Continuous Methane Monitoring: (5a) Modeling and design of an optics platform complementary to the constructed electronics platform for successful incorporation into ''sphereIR'' continues. AutoCAD design and manual construction of mounting pieces for major optical components have been completed. (5b) Initial design concepts for IR-ATR sensor probe geometries have been established and evaluated. Initial evaluations of a horizontal ATR (HATR) sensing probe with fiber optic guiding light have been performed and validate the design concept as a potentially viable deep sea sensing probe. (5c) Ray tracing simulations have been performed to evaluate light propagation through HATR elements to facilitate the optimal design of both the sensing probe and optical configuration of ''sphereIR''. (5d) The highly permeable polymer, polydimethylsiloxane (PDMS), was investigated as a potential methane enrichment membrane for IR-ATR sensors. (6) Progress on the Seismo-acoustic Characterization of Sea Floor Properties and Processes at the Hydrate Monitoring Station: (6a) All system components underwent extensive testing in preparation for determining sea floor acoustic reflection responses at the Gas Hydrate Monitoring Station. (6b) Final testing and commissioning have been completed.« less
5. Photographic copy of architectural floor plans for Officers' Quarters ...
5. Photographic copy of architectural floor plans for Officers' Quarters "A" & "B": Taylor & Barnes, Architects & Engineers, 803 W. Third Street, Los Angeles California, O.C.E. Office of Civil Engineer Job No. Muroc ESA 210-48 and 210-49, Military Construction: Muroc Flight Test Base, Muroc, California, Warehouses and Additional Housing for Officers: Officers Quarters, Floor Plan, Foundation Plan & Details, Sheet No. 12 of 16, May 1945. Reproduced from the holdings of the National Archives, Pacific Southwest Region - Edwards Air Force Base, North Base, Officers' Quarters A, North Base Road, Boron, Kern County, CA
Wagenlehner, Florian Martin Erich; Fröhlich, Oliver; Bschleipfer, Thomas; Weidner, Wolfgang; Perletti, Gianpaolo
2014-06-01
Anatomical damage to pelvic floor structures may cause multiple symptoms. The Integral Theory System Questionnaire (ITSQ) is a holistic questionnaire that uses symptoms to help locate damage in specific connective tissue structures as a guide to reconstructive surgery. It is based on the integral theory, which states that pelvic floor symptoms and prolapse are both caused by lax suspensory ligaments. The aim of the present study was to psychometrically validate the ITSQ. Established psychometric properties including validity, reliability, and responsiveness were considered for evaluation. Criterion validity was assessed in a cohort of 110 women with pelvic floor dysfunctions by analyzing the correlation of questionnaire responses with objective clinical data. Test-retest was performed with questionnaires from 47 patients. Cronbach's alpha and "split-half" reliability coefficients were calculated for inner consistency analysis. Psychometric properties of ITSQ were comparable to the ones of previously validated Pelvic Floor Questionnaires. Face validity and content validity were approved by an expert group of the International Collaboration of Pelvic Floor surgeons. Convergent validity assessed using Bayesian method was at least as accurate as the expert assessment of anatomical defects. Objective data measurement in patients demonstrated significant correlations with ITSQ domains fulfilling criterion validity. Internal consistency values ranked from 0.85 to 0.89 in different scenarios. The ITSQ proofed accurate and is able to serve as a holistic Pelvic Floor Questionnaire directing symptoms to site-specific pelvic floor reconstructive surgery.
Onishi, Keisuke
2017-01-01
Commissural axons switch on responsiveness to Wnt attraction during midline crossing and turn anteriorly only after exiting the floor plate. We report here that Sonic Hedgehog (Shh)-Smoothened signaling downregulates Shisa2, which inhibits the glycosylation and cell surface presentation of Frizzled3 in rodent commissural axon growth cones. Constitutive Shisa2 expression causes randomized turning of post-crossing commissural axons along the anterior–posterior (A–P) axis. Loss of Shisa2 led to precocious anterior turning of commissural axons before or during midline crossing. Post-crossing commissural axon turning is completely randomized along the A–P axis when Wntless, which is essential for Wnt secretion, is conditionally knocked out in the floor plate. This regulatory link between Shh and planar cell polarity (PCP) signaling may also occur in other developmental processes. PMID:28885142
Biomechanical paradigm and interpretation of female pelvic floor conditions before a treatment
Lucente, Vincent; van Raalte, Heather; Murphy, Miles; Egorov, Vladimir
2017-01-01
Background Further progress in restoring a woman’s health may be possible if a patient with a damaged pelvic floor could undergo medical imaging and biomechanical diagnostic tests. The results of such tests could contribute to the analysis of multiple treatment options and suggest the optimal one for that patient. Aim To develop a new approach for the biomechanical characterization of vaginal conditions, muscles, and connective tissues in the female pelvic floor. Methods Vaginal tactile imaging (VTI) allows biomechanical assessment of the soft tissue along the entire length of the anterior, posterior, and lateral vaginal walls at rest, with manually applied deflection pressures and with muscle contraction, muscle relaxation, and Valsalva maneuver. VTI allows a large body of measurements to evaluate individual variations in tissue elasticity, support defects, as well as pelvic muscle function. Presuming that 1) the female pelvic floor organs are suspended by ligaments against which muscles contract to open or close the outlets and 2) damaged ligaments weaken the support and may reduce the force of muscle contraction, we made an attempt to characterize multiple pelvic floor structures from VTI data. Results All of the 138 women enrolled in the study were successfully examined with the VTI. The study subjects have had normal pelvic support or pelvic organ prolapse (stages I–IV). The average age of this group of subjects was 60±15 years. We transposed a set of 31 VTI parameters into a quantitative characterization of pelvic muscles and ligamentous structures. Interpretation of the acquired VTI data for normal pelvic floor support and prolapse conditions is proposed based on biomechanical assessment of the functional anatomy. Conclusion Vaginal tactile imaging allows biomechanical characterization of female pelvic floor structures and tissues in vivo, which may help to optimize treatment of the diseased conditions such as prolapse, incontinence, atrophy, and some forms of pelvic pain. PMID:28831274
Metz, Melanie; Junginger, Bärbel; Henrich, Wolfgang; Baeßler, Kaven
2017-04-01
Introduction The aim of this study was to develop and validate a questionnaire for the assessment of pelvic floor disorders, their symptoms and risk factors in pregnancy and after birth including symptom course, severity and impact on quality of life. Methods The validated German pelvic floor questionnaire was modified and a new risk factor domain developed. The questionnaire was initially completed by 233 nulliparous women in the third trimester of pregnancy and at six weeks (n = 148) and one year (n = 120) post partum. Full pyschometric testing was performed. The clinical course of symptoms and the influence of risk factors were analysed. Results Study participants had a median age of 31 (19-46) years. 63 % had spontaneous vaginal deliveries, 15 % operative vaginal deliveries and 22 % were delivered by caesarean section. Content validity: Missing answers never exceeded 4 %. Construct validity: The questionnaire distinguished significantly between women who reported bothersome symptoms and those who did not. Reliability: Cronbach's alpha values exceeded 0.7 for bladder, bowel and support function, and 0.65 for sexual function. The test-retest analysis showed moderate to almost complete concordance. The intraclass coefficients for domain scores (between 0.732 and 0.818) were in acceptable to optimal range. Reactivity: The questionnaire was able to track changes significantly with good effect size for each domain. Risk factors for pelvic floor symptoms included familial predisposition, maternal age over 35 years, BMI above 25, nicotine abuse, subjective inability to voluntarily contract the pelvic floor musculature and postpartum wound pain. Conclusion This pelvic floor questionnaire proved to be valid, reliable and reactive for the assessment of pelvic floor disorders, their risk factors, incidence and impact on quality of life during pregnancy and post partum. The questionnaire can be utilised to assess the course of symptoms and treatment effects using a scoring system.
Female Pelvic Floor Biomechanics: Bridging the Gap
Easley, Deanna C.; Abramowitch, Steven D.; Moalli, Pamela A.
2017-01-01
Purpose of review The pelvic floor is a complex assembly of connective tissues and striated muscle that simultaneously counteract gravitational forces, inertial forces, and intraabdominal pressures while maintaining the position of the pelvic organs. In 30% of women, injury or failure of the pelvic floor results in pelvic organ prolapse (POP). Surgical treatments have high recurrence rates, due, in part, to a limited understanding of physiologic loading conditions. It is critical to apply biomechanics to help elucidate how altered loading conditions of the pelvis contribute to the development of pelvic organ prolapse and to define surgeries to restore normal support. Recent findings Evidence suggests the ewe is a potential animal model for studying vaginal properties and that uterosacral and cardinal ligaments experience significant creep, which may be affecting surgical outcomes. A new method of measuring ligament displacements in vivo was developed, and finite element models that simulate urethral support, pelvic floor dynamics, and the impact of episiotomies on the pelvic floor were studied. Summary This review highlights some contributions over the past year, including mechanical testing and the creation of models, which are used to understand pelvic floor changes with loading, and the impact of surgical procedures, to illustrate how biomechanics is being utilized. PMID:28267057
A dual-rating method for evaluating impact noise isolation of floor-ceiling assemblies.
LoVerde, John J; Dong, D Wayland
2017-01-01
Impact Insulation Class (IIC), the single-number rating for evaluating the impact noise insulation of a floor-ceiling assembly, and the associated field testing ratings, are unsatisfactory because they do not have strong correlation with subjective reaction nor provide suitable detailed information for evaluation or design of floor-ceiling assemblies. Various proposals have been made for improving the method, but the data presented indicate that no single-number rating can adequately characterize the impact noise isolation of an assembly. For realistic impact noise sources and floor-ceiling assembly types, there are two frequency domains for impact noise, and the impact noise levels in the two domains can vary independently. Therefore, two ratings are required in order to satisfactorily evaluate the impact isolation provided by a floor-ceiling assembly. Two different ratings are introduced for measuring field impact isolation in the two frequency domains, using the existing impact source and measurement method. They are named low-frequency impact rating (LIR) and high-frequency impact rating (HIR). LIR and HIR are proposed to improve the current method for design and evaluation of floor-ceiling assemblies and also provide a better method for predicting subjective reaction.
Mazzone, Elena; Martinelli, Diego; Berardinelli, Angela; Messina, Sonia; D'Amico, Adele; Vasco, Gessica; Main, Marion; Doglio, Luca; Politano, Luisa; Cavallaro, Filippo; Frosini, Silvia; Bello, Luca; Carlesi, Adelina; Bonetti, Anna Maria; Zucchini, Elisabetta; De Sanctis, Roberto; Scutifero, Marianna; Bianco, Flaviana; Rossi, Francesca; Motta, Maria Chiara; Sacco, Annalisa; Donati, Maria Alice; Mongini, Tiziana; Pini, Antonella; Battini, Roberta; Pegoraro, Elena; Pane, Marika; Pasquini, Elisabetta; Bruno, Claudio; Vita, Giuseppe; de Waure, Chiara; Bertini, Enrico; Mercuri, Eugenio
2010-11-01
The North Star Ambulatory Assessment is a functional scale specifically designed for ambulant boys affected by Duchenne muscular dystrophy (DMD). Recently the 6-minute walk test has also been used as an outcome measure in trials in DMD. The aim of our study was to assess a large cohort of ambulant boys affected by DMD using both North Star Assessment and 6-minute walk test. More specifically, we wished to establish the spectrum of findings for each measure and their correlation. This is a prospective multicentric study involving 10 centers. The cohort included 112 ambulant DMD boys of age ranging between 4.10 and 17 years (mean 8.18±2.3 DS). Ninety-one of the 112 were on steroids: 37/91 on intermittent and 54/91 on daily regimen. The scores on the North Star assessment ranged from 6/34 to 34/34. The distance on the 6-minute walk test ranged from 127 to 560.6 m. The time to walk 10 m was between 3 and 15 s. The time to rise from the floor ranged from 1 to 27.5 s. Some patients were unable to rise from the floor. As expected the results changed with age and were overall better in children treated with daily steroids. The North Star assessment had a moderate to good correlation with 6-minute walk test and with timed rising from floor but less with 10 m timed walk/run test. The 6-minute walk test in contrast had better correlation with 10 m timed walk/run test than with timed rising from floor. These findings suggest that a combination of these outcome measures can be effectively used in ambulant DMD boys and will provide information on different aspects of motor function, that may not be captured using a single measure. Copyright © 2010. Published by Elsevier B.V.
FAST CHOPPER DETECTOR HOUSE, TRA665. FIRST FLOOR, PLAN AND SECTION, ...
FAST CHOPPER DETECTOR HOUSE, TRA-665. FIRST FLOOR, PLAN AND SECTION, AS PROPOSED FOR MODIFICATION IN 1962. CONCRETE WALLS THREE FEET THICK. EXISTING WINDOWS IN MTR AND DETECTOR HOUSE WALLS WERE TO BE FILLED IN WITH HIGH-DENSITY BRICK. NOTE 20-METER MARK, WHERE THE FAST CHOPPER DETECTOR HAD BEEN LOCATED. F.C. TORKELSON 842-MTR-665-S-2, 4/1962. INL INDEX NO. 531-0665-60-851-150996, REV. 5. - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
14. CONTROL PANELS, EAST SIDE, MAIN FLOOR: TO LEFT (ORIGINAL ...
14. CONTROL PANELS, EAST SIDE, MAIN FLOOR: TO LEFT (ORIGINAL EQUIPMENT): UPPER FOUR GLASS BOXES ARE OVERCURRENT PROTECTIVE RELAYS; MIDDLE FOUR GLASS BOXES CONTAIN TESTING SWITCHES; LOWER TWO BOXES ARE DG1 METERING CHART RECORDERS TO RIGHT (MODERN EQUIPMENT): UPPER FOUR BLACK BOXES ARE PROTECTIVE SERVICE RELAYS; MIDDLE FOUR BOXES CONTAIN TESTING SWITCHES; LARGE BOX BELOW HOUSES REMOTE METERING SYSTEM METAL CABINETS (LABELED L-2 & L-4) BELOW CONTAIN ORIGINAL POWER CIRCUIT BREAKERS - Bonneville Power Administration South Bank Substation, I-84, South of Bonneville Dam Powerhouse, Bonneville, Multnomah County, OR
Validity of the Jump-and-Reach Test in Subelite Adolescent Handball Players.
Muehlbauer, Thomas; Pabst, Jan; Granacher, Urs; Büsch, Dirk
2017-05-01
Muehlbauer, T, Pabst, J, Granacher, U, and Büsch, D. Validity of the jump-and-reach test in subelite adolescent handball players. J Strength Cond Res 31(5): 1282-1289, 2017-The primary purpose of this study was to examine concurrent validity of the jump-and-reach (JaR) test using the Vertec system and a criterion device (i.e., Optojump system). In separate subanalyses, we investigated the influence of gym floor condition and athletes' sex on the validity of vertical jump height. Four hundred forty subelite adolescent female (n = 222, mean age: 14 ± 1 year, age range: 13-15 years) and male (n = 218, mean age: 15 ± 1 year, age range: 14-16 years) handball players performed the JaR test in gyms with region or point elastic floors. Maximal vertical jump height was simultaneously assessed using the Vertec and the Optojump systems. In general, significantly higher jump heights were obtained for the Vertec compared with the Optojump system (11.2 cm, Δ31%, Cohen's d = 2.58). The subanalyses revealed significantly larger jump heights for the Vertec compared with the Optojump system irrespective of gym floor condition and players' sex. The association between Optojump- and Vertec-derived vertical jump heights amounted to rP = 0.84, with a coefficient of determination (R) of 0.71. The subanalyses indicated significantly larger correlations in males (rP = 0.75, R = 0.56) than in females (rP = 0.63, R = 0.40). Yet, correlations were not significantly different between region (rP = 0.83, R = 0.69) as opposed to point elastic floor (rP = 0.87, R = 0.76). Our findings indicate that the 2 apparatuses cannot be used interchangeably. Consequently, gym floor and sex-specific regression equations were provided to estimate true (Optojump system) vertical jump height from Vertec-derived data.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Hazardous Air Pollutants: Mercury Emissions From Mercury Cell Chlor-Alkali Plants Pt. 63, Subpt. IIIII...; cracks or spalling in cell room floors, pillars, or beams; caustic leaks; liquid mercury accumulations or... through a detection cell where ultraviolet light at 253.7 nanometers (nm) is directed perpendicularly...
Code of Federal Regulations, 2014 CFR
2014-07-01
... Hazardous Air Pollutants: Mercury Emissions From Mercury Cell Chlor-Alkali Plants Pt. 63, Subpt. IIIII...; cracks or spalling in cell room floors, pillars, or beams; caustic leaks; liquid mercury accumulations or... through a detection cell where ultraviolet light at 253.7 nanometers (nm) is directed perpendicularly...
Code of Federal Regulations, 2013 CFR
2013-07-01
... Hazardous Air Pollutants: Mercury Emissions From Mercury Cell Chlor-Alkali Plants Pt. 63, Subpt. IIIII...; cracks or spalling in cell room floors, pillars, or beams; caustic leaks; liquid mercury accumulations or... through a detection cell where ultraviolet light at 253.7 nanometers (nm) is directed perpendicularly...
Crash tests of three identical low-wing single-engine airplane
NASA Technical Reports Server (NTRS)
Castle, C. B.; Alfaro-Bou, E.
1983-01-01
Three identical four place, low wing single engine airplane specimens with nominal masses of 1043 kg were crash tested under controlled free flight conditions. The tests were conducted at the same nominal velocity of 25 m/sec along the flight path. Two airplanes were crashed on a concrete surface (at 10 and 30 deg pitch angles), and one was crashed on soil (at a -30 deg pitch angle). The three tests revealed that the specimen in the -30 deg test on soil sustained massive structural damage in the engine compartment and fire wall. Also, the highest longitudinal cabin floor accelerations occurred in this test. Severe damage, but of lesser magnitude, occurred in the -30 deg test on concrete. The highest normal cabin floor accelerations occurred in this test. The least structural damage and lowest accelerations occurred in the 10 deg test on concrete.
Development and Testing of a Mobile Platform for Tank Remediation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nance, T.A.
2001-01-16
The Department of Energy (DOE) is committed to removing millions of gallons of high level radioactive waste from waste storage tanks at the Savannah River Site (SRS). SRS was the first site in the DOE complex to have emptied and closed high level waste tanks. Tank closure at the Site is now progressing to tanks containing waste composed of liquid and large deposits of solids, including a tank that has a potential ''heel''. A heel is a hardened mass of solid waste material spread across the tank bottom. Tank closure requires breaking up this heel and moving the material tomore » the intake of a pumping system for transfer from the tank. In the past, overhead spray systems have been used with some success at moving waste. But the limited number of risers restricts the coverage area of the overhead spray system. Therefore, a floor- level spray system will be used to separate manageable size chunks of the material from the heel. The chunks will be guided into the pump's intake to be remove from the tank. The floor-level spray system movement will be accomplished by using a mobile platform, a crawler, which provides transport to nearly every point on the tank floor. Transport of the spray system will allow the system to ''corral'' the waste away from the tank walls and control the movement of the material across the tank floor. Because the available access riser is small, and a wide crawler platform is required to support the spray system, the crawler's frame must fold to enter the tank. After entry into the tank, the crawler unfolds on the tank floor using the crawler drive tracks to expand the frame and position the mobile platform under the entry riser. The spray system will then be lowered separately through the entry riser and mated onto the crawler on the tank floor. The crawler and spray system are tethered and controlled remotely by personnel at the control station. Motorized cable reels will also be remotely controlled to pay out, retrieve, and manage the tethers as the mobile platform moves the spray system across the tank floor. Both the crawler and spray systems are designed to be retrievable. Development of the tank cleaning system was evaluated using a performance test program. The tests evaluated the spray system dynamics, the crawler's fit through the riser, the crawler landing in mocked up tank with simulant, the crawler's traction, and the crawler and spray system mating. Initial testing verified the crawler platform was compatible with the dynamics produced by the spray system. The riser fit test confirmed that a dedicated riser is required for deployment of the crawler and the spray system. The crawler traction test defined the capabilities of the crawler at different levels of simulant. Deployment testing through a mockup riser verified the basic system processes. Finally, testing of the complete system in a full-scale mockup with sludge simulant was performed to evaluate the tank cleaning ability of the crawler. This paper describes th e tank conditions, the tank closure process, the development of the crawler and spray system, and the testing program and results used to evaluate the mobile platform and spray system.« less
40 CFR Table 9 to Subpart IIIii of... - Required Records for Work Practice Standards
Code of Federal Regulations, 2010 CFR
2010-07-01
... Mercury Cell Chlor-Alkali Plants Pt. 63, Subpt. IIIII, Table 9 Table 9 to Subpart IIIII of Part 63... other deficiency in a cell room floor, pillar, or beam that could cause liquid mercury to become trapped.... f. If you take a cell off line or isolate the leaking equipment, the date and time you take the cell...
40 CFR Table 9 to Subpart IIIii of... - Required Records for Work Practice Standards
Code of Federal Regulations, 2014 CFR
2014-07-01
... Mercury Cell Chlor-Alkali Plants Pt. 63, Subpt. IIIII, Table 9 Table 9 to Subpart IIIII of Part 63... other deficiency in a cell room floor, pillar, or beam that could cause liquid mercury to become trapped.... f. If you take a cell off line or isolate the leaking equipment, the date and time you take the cell...
40 CFR Table 9 to Subpart IIIii of... - Required Records for Work Practice Standards
Code of Federal Regulations, 2013 CFR
2013-07-01
... Mercury Cell Chlor-Alkali Plants Pt. 63, Subpt. IIIII, Table 9 Table 9 to Subpart IIIII of Part 63... other deficiency in a cell room floor, pillar, or beam that could cause liquid mercury to become trapped.... f. If you take a cell off line or isolate the leaking equipment, the date and time you take the cell...
Sun, Zhi-Jing; Zhu, Lan; Liang, Maolian; Xu, Tao; Lang, Jing-He
2016-08-01
WeChat is a promising tool for capturing electronic data; however, no research has examined its use. This study evaluates the reliability and feasibility of WeChat for administering the Pelvic Floor Impact Questionnaire Short Form 7 questionnaire to women with pelvic floor disorders. Sixty-eight pelvic floor rehabilitation women were recruited between June and December 2015 and crossover randomized to two groups. All participants completed two questionnaire formats. One group completed the paper version followed by the WeChat version; the other group completed the questionnaires in reverse order. Two weeks later, each group completed the two versions in reverse order. The WeChat version's reliability was assessed using intraclass correlation coefficients and test-retest reliability. Forty-two women (61.8%) preferred the WeChat to the paper format, eight (11.8%) preferred the paper format, and 18 (26.5%) had no preference. The younger women preferred WeChat. Completion time was 116.5 (61.3) seconds for the WeChat version and 133.4 (107.0) seconds for the paper version, with no significant difference (P = 0.145). Age and education did not impact completion time (P > 0.05). Consistency between the WeChat and paper versions was excellent. The intraclass correlation coefficients of the Pelvic Floor Impact Questionnaire Short Form 7 and the three subscales ranged from 0.915 to 0.980. The Bland-Altman analysis and linear regression results also showed high consistency. The test-retest study had a Pearson's correlation coefficient of 0.908, demonstrating a strong correlation. WeChat-based questionnaires were well accepted by women with pelvic floor disorders and had good data quality and reliability.
Surani, Salim; Hesselbacher, Sean; Guntupalli, Bharat; Surani, Sara; Subramanian, Shyam
2015-12-01
Sleepiness in nurses has been shown to impact patient care and safety. The objectives of this study are to measure sleep quality, sleepiness, fatigue, and vigilance in inpatient nurses and to assess how setting (intensive care unit versus the general floor) and shift worked (day versus night) affect these measures. Nurses from both the ICU and floor were included in the study. Participants completed questionnaires assessing self-reported sleep quality (Pittsburgh Sleep Quality Index, PSQI), sleepiness (Stanford Sleepiness Scale and Epworth Sleepiness Scale, ESS), and fatigue (Fatigue Severity Scale, FSS). Vigilance was measured by means of the psychomotor vigilance test (PVT), before and after a 12-hour duty shift. The ESS was abnormal in 22% of all nurses, the FSS was abnormal in 33%, and the global PSQI was abnormal in 63%. More ICU nurses than floor nurses reported abnormal sleep quality (component 5) on the PSQI. Sleep medication use (PSQI component 6) was higher in night shift nurses. The FSS was greater in night shift nurses. On preshift PVT testing, day-shift nurses overall provided faster mean reaction time (RT) than night-shift nurses. ICU nurses working the day shift made more than twice as many total errors and false starts than day shift floor nurses. Floor nurses demonstrated a significant decrease from preshift to postshift in the mean of the fastest 10% RT. Our data indicate that a significant number of inpatient nurses have impaired sleep quality, excessive sleepiness, and abnormal fatigue, which may place them at a greater risk of making medical errors and harming patients; these problems are especially pronounced in night shift workers. PVT results were inconsistent, but floor and day shift nurses performed better on some tasks than ICU and night shift nurses.
Examination of space/volume requirements for US underground coal mine refuge alternatives.
Porter, William L; Dempsey, Patrick G; Jansky, Jacqueline H
2017-01-01
The Mine Safety and Health Administration requires that 1.4 m 2 (15 ft 2 ) of floor space is to be provided for each person inside a refuge alternative (RA). However, the amount of floor space needed for a person to reside inside an RA and perform basic tasks is unknown. During testing, participants entered into an RA or a simulated RA of various space/volume configurations and performed several simulated tasks that are representative of the survivability tasks performed within an RA. The results indicate that the floor space requirements were generally adequate for the tasks studied. Certain tasks such as changing scrubber cartridges, using toilets, and moving about the RA were impacted by the minimum height tested (0.6 m). As such, RAs of this height will require critical design consideration as a whole and the supplies provided for use inside of the RA to ensure the ability to use an RA.
FET. Control and equipment building (TAN630). Basement floor plan. Tunnel ...
FET. Control and equipment building (TAN-630). Basement floor plan. Tunnel to hangar (TAN-629). Electrical and chemical services. Ralph M. Parsons 1229-2 ANP/GE-630-A-1. Date: March 1957. Approved by INEEL Classification Office for public release. INEEL index code no. 036-0630-00-693-107080 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
36. INTERIOR VIEW TO THE NORTHWEST OF THE SECOND FLOOR ...
36. INTERIOR VIEW TO THE NORTHWEST OF THE SECOND FLOOR CORRIDOR ON THE EAST SIDE OF THE DISASSEMBLY BAY. A VIEWING AND WORK STATION AND ENTRANCE TO THE CONTROL ROOM ARE ON THE WEST SIDE OF THE CORRIDOR. - Nevada Test Site, Reactor Maintenance Assembly & Dissassembly Facility, Area 25, Jackass Flats, Junction of Roads F & G, Mercury, Nye County, NV
ADM. Fuel Pump House (TAN611). Elevations, floor plan. Drawing includes ...
ADM. Fuel Pump House (TAN-611). Elevations, floor plan. Drawing includes elevation and plans for "H.M." structures (Hose Storage?). Ralph M. Parsons 902-2-ANP-611-A 78 Date: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 035-0611-00-693-106741 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
The Tower and Glass Marbles Problem
ERIC Educational Resources Information Center
Denman, Richard T.; Hailey, David; Rothenberg, Michael
2010-01-01
The Catseye Marble company tests the strength of its marbles by dropping them from various levels of their office tower, to find the highest floor from which a marble will not break. We find the smallest number of drops required and from which floor each drop should be made. We also find out how these answers change if a restriction is placed on…
FET. Control and equipment building, TAN630. Main floor plan. Control ...
FET. Control and equipment building, TAN-630. Main floor plan. Control room. Room numbers and functions. Ralph M. Parsons. 1229-2-ANP/GE-5-630-A-2. Date: March 1957. Approved by INEEL Classification Office for public release. INEEL index code no. 036-0630-00-693-107081 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
A&M. TAN607. Foundation plan for hot shop floor and pool. ...
A&M. TAN-607. Foundation plan for hot shop floor and pool. Tunnels to turntable. Motor pit. Ralph M. Parsons 902-3-ANP-607-S128. Date: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 034-0607-62-693-160722 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
A&M. TAN607 second floor plan for cold assembly area. Metallurgical ...
A&M. TAN-607 second floor plan for cold assembly area. Metallurgical lab, chemistry lab, nuclear instrument lab, equipment rooms. Ralph M. Parsons 902-ANP-607-A 102. Date: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 034-0607-693-106754 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
4. "ARCHITECTURAL, FLOOR PLAN-ELEVATIONS-SECTIONS, OBSERVATION BUNKERS." Specifications No. ENG (NASA)04-353-63-1; Drawing No. 60-09-34; sheet 325. Ref. No. A-13. D.O. SERIES 1597/87. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Observation Bunker 1-D-3, Test Area 1-125, northwest end of Altair Boulevard, Boron, Kern County, CA
2D and 3D Traveling Salesman Problem
ERIC Educational Resources Information Center
Haxhimusa, Yll; Carpenter, Edward; Catrambone, Joseph; Foldes, David; Stefanov, Emil; Arns, Laura; Pizlo, Zygmunt
2011-01-01
When a two-dimensional (2D) traveling salesman problem (TSP) is presented on a computer screen, human subjects can produce near-optimal tours in linear time. In this study we tested human performance on a real and virtual floor, as well as in a three-dimensional (3D) virtual space. Human performance on the real floor is as good as that on a…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-01-12
... frames, upper deck floor beams, electronic bay access door cutout, nose wheel well, and main entry doors... intervals for certain airplanes. This AD results from fatigue tests and analysis that identified additional... frames, upper deck floor beams, electronic bay access door cutout, nose wheel well, and main entry doors...
Hasegawa, Kouichi; Menheniott, Trevelyan; Rollo, Ben; Zhang, Dongcheng; Hough, Shelley; Alshawaf, Abdullah; Febbraro, Fabia; Ighaniyan, Samiramis; Leung, Jessie; Elliott, David A.; Newgreen, Donald F.; Pera, Martin F.
2015-01-01
Abstract The caudal neural plate is a distinct region of the embryo that gives rise to major progenitor lineages of the developing central and peripheral nervous system, including neural crest and floor plate cells. We show that dual inhibition of the glycogen synthase kinase 3β and activin/nodal pathways by small molecules differentiate human pluripotent stem cells (hPSCs) directly into a preneuroepithelial progenitor population we named “caudal neural progenitors” (CNPs). CNPs coexpress caudal neural plate and mesoderm markers, and, share high similarities to embryonic caudal neural plate cells in their lineage differentiation potential. Exposure of CNPs to BMP2/4, sonic hedgehog, or FGF2 signaling efficiently directs their fate to neural crest/roof plate cells, floor plate cells, and caudally specified neuroepithelial cells, respectively. Neural crest derived from CNPs differentiated to neural crest derivatives and demonstrated extensive migratory properties in vivo. Importantly, we also determined the key extrinsic factors specifying CNPs from human embryonic stem cell include FGF8, canonical WNT, and IGF1. Our studies are the first to identify a multipotent neural progenitor derived from hPSCs, that is the precursor for major neural lineages of the embryonic caudal neural tube. Stem Cells 2015;33:1759–1770 PMID:25753817
Characterizing performance of ultra-sensitive accelerometers
NASA Technical Reports Server (NTRS)
Sebesta, Henry
1990-01-01
An overview is given of methodology and test results pertaining to the characterization of ultra sensitive accelerometers. Two issues are of primary concern. The terminology ultra sensitive accelerometer is used to imply instruments whose noise floors and resolution are at the state of the art. Hence, the typical approach of verifying an instrument's performance by measuring it with a yet higher quality instrument (or standard) is not practical. Secondly, it is difficult to find or create an environment with sufficiently low background acceleration. The typical laboratory acceleration levels will be at several orders of magnitude above the noise floor of the most sensitive accelerometers. Furthermore, this background must be treated as unknown since the best instrument available is the one to be tested. A test methodology was developed in which two or more like instruments are subjected to the same but unknown background acceleration. Appropriately selected spectral analysis techniques were used to separate the sensors' output spectra into coherent components and incoherent components. The coherent part corresponds to the background acceleration being measured by the sensors being tested. The incoherent part is attributed to sensor noise and data acquisition and processing noise. The method works well for estimating noise floors that are 40 to 50 dB below the motion applied to the test accelerometers. The accelerometers being tested are intended for use as feedback sensors in a system to actively stabilize an inertial guidance component test platform.
Xia, Lunguo; Xu, Yuanjin; Chang, Qing; Sun, Xiaojuan; Zeng, Deliang; Zhang, Wenjie; Zhang, Xiuli; Zhang, Zhiyuan; Jiang, Xinquan
2011-07-01
This study evaluated the synergistic osteogenic effect of bone morphogenetic protein-2 (BMP-2) and Nel-like molecule-1 (Nell-1) genes in a rabbit maxillary sinus floor elevation model. Bone marrow stromal cells (bMSCs) were cultured and transduced with AdEGFP, AdNell-1, AdBMP-2, or AdNell-1 + AdBMP-2 overexpression virus. These gene-modified autologous bMSCs were then combined with a β-tricalcium phosphate (β-TCP) granule scaffold and used to elevate the maxillary sinus floor in rabbits. bMSCs cotransduced with AdNell-1 + AdBMP-2 demonstrated a synergistic effect on osteogenic differentiation as detected by real-time PCR analysis on markers of runt-related transcription factor-2, osteocalcin, collagen type 1, alkaline phosphatase activity, and calcium deposits in vitro. As for maxillary sinus floor elevation in a rabbit model in vivo, AdNell-1 + AdBMP-2 gene-transduced autologeous bMSCs/β-TCP complex had the largest bone area and most mature bone structure among the groups, as detected by HE staining and immunohistochemistry at weeks 2 and 8 after implantation. Our data suggested that the BMP-2 and Nell-1 genes possessed a synergistic effect on osteogenic differentiation of bMSCs, while bMSCs modified with the BMP-2 and Nell-1 genes could promote new bone formation and maturation in the rabbit maxillary sinus model.
Maddalena, R; Mendell, M J; Eliseeva, K; Chan, W R; Sullivan, D P; Russell, M; Satish, U; Fisk, W J
2015-08-01
Ventilation rates (VRs) in buildings must adequately control indoor levels of pollutants; however, VRs are constrained by the energy costs. Experiments in a simulated office assessed the effects of VR per occupant on perceived air quality (PAQ), Sick Building Syndrome (SBS) symptoms, and decision-making performance. A parallel set of experiments assessed the effects of VR per unit floor area on the same outcomes. Sixteen blinded healthy young adult subjects participated in each study. Each exposure lasted four hours and each subject experienced two conditions in a within-subject study design. The order of presentation of test conditions, day of testing, and gender were balanced. Temperature, relative humidity, VRs, and concentrations of pollutants were monitored. Online surveys assessed PAQ and SBS symptoms and a validated computer-based tool measured decision-making performance. Neither changing the VR per person nor changing the VR per floor area, had consistent statistically significant effects on PAQ or SBS symptoms. However, reductions in either occupant-based VR or floor-area-based VR had a significant and independent negative impact on most decision-making measures. These results indicate that the changes in VR employed in the study influence performance of healthy young adults even when PAQ and SBS symptoms are unaffected. The study results indicate the importance of avoiding low VRs per person and low VRs per floor area to minimize decrements in cognitive performance. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Sonic hedgehog in the notochord is sufficient for patterning of the intervertebral discs
Choi, Kyung-Suk; Lee, Chanmi; Harfe, Brian D.
2012-01-01
The intervertebral discs, located between adjacent vertebrae, are required for stability of the spine and distributing mechanical load throughout the vertebral column. All cell types located in thes middle regions of the discs, called nuclei pulposi, are derived from the embryonic notochord. Recently, it was shown that the hedgehog signaling pathway plays an essential role during formation of nuclei pulposi. However, during the time that nuclei pulposi are forming, Shh is expressed in both the notochord and the nearby floor plate. To determine the source of SHH protein sufficient for formation of nuclei pulposi we removed Shh from either the floor plate or the notochord using tamoxifen-inducible Cre alleles. Removal of Shh from the floor plate resulted in phenotypically normal intervertebral discs, indicating that Shh expression in this tissue is not required for disc patterning. In addition, embryos that lacked Shh in the floor plate had normal vertebral columns, demonstrating that Shh expression in the notochord is sufficient for pattering the entire vertebral column. Removal of Shh from the notochord resulted in the absence of Shh in the floor plate, loss of intervertebral discs and vertebral structures. These data indicate that Shh expression in the notochord is sufficient for patterning of the intervertebral discs and the vertebral column. PMID:22841806
Sonic hedgehog in the notochord is sufficient for patterning of the intervertebral discs.
Choi, Kyung-Suk; Lee, Chanmi; Harfe, Brian D
2012-01-01
The intervertebral discs, located between adjacent vertebrae, are required for stability of the spine and distributing mechanical load throughout the vertebral column. All cell types located in the middle regions of the discs, called nuclei pulposi, are derived from the embryonic notochord. Recently, it was shown that the hedgehog signaling pathway plays an essential role during formation of nuclei pulposi. However, during the time that nuclei pulposi are forming, Shh is expressed in both the notochord and the nearby floor plate. To determine the source of SHH protein sufficient for formation of nuclei pulposi we removed Shh from either the floor plate or the notochord using tamoxifen-inducible Cre alleles. Removal of Shh from the floor plate resulted in phenotypically normal intervertebral discs, indicating that Shh expression in this tissue is not required for disc patterning. In addition, embryos that lacked Shh in the floor plate had normal vertebral columns, demonstrating that Shh expression in the notochord is sufficient for pattering the entire vertebral column. Removal of Shh from the notochord resulted in the absence of Shh in the floor plate, loss of intervertebral discs and vertebral structures. These data indicate that Shh expression in the notochord is sufficient for patterning of the intervertebral discs and the vertebral column. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Keleş, A; Keskin, C
2018-02-01
To conduct a quantitative and qualitative analysis of the band-shaped isthmus area, the floor of which was in the apical third in the mesial roots of mandibular first molars using micro-computed tomography (micro-CT). Micro-CT images of 269 mesial roots of mandibular first molars were evaluated, and 40 specimens with a band-shaped isthmus, with a floor in the apical third, were selected. The major diameter, minor diameter, roundness, area and perimeter values for the most coronal and apical slices where the isthmus was visible were measured. The distances between these slices were measured as the isthmus length, and the total volume, structure model index and surface area of the isthmus were measured. The distances between the isthmus floor and two apical foramina and the number of root canal orifices were calculated. The dimensions of the isthmus roof and the floor were compared, and the data were analysed using descriptive statistics and Student's t-tests with a significance threshold set at 5%. A total of 15% of the specimens had band-shaped isthmuses with a floor in the apical third. The isthmus roof exhibited significantly greater major and minor diameter values compared to the isthmus floor (P < 0.05). No significant difference was detected between the isthmus roof and the floor with regard to roundness (P > 0.05). Three- and two-dimensional analyses of the mesial roots of mandibular molars revealed that band-shaped isthmuses had complex shapes. © 2017 International Endodontic Journal. Published by John Wiley & Sons Ltd.
40 CFR Table 2 to Subpart IIIii of... - Work Practice Standards-Required Inspections
Code of Federal Regulations, 2010 CFR
2010-07-01
... Mercury Cell Chlor-Alkali Plants Pt. 63, Subpt. IIIII, Table 2 Table 2 to Subpart IIIII of Part 63—Work... must . . . 1. Each vent hose on each mercury cell Half day A leaking vent hose Take action immediately... mercury seal pot stopper securely in place. 6. Cell room floors Month Cracks, spalling, or other...
Regular exercisers have stronger pelvic floor muscles than nonregular exercisers at midpregnancy.
Bø, Kari; Ellstrøm Engh, Marie; Hilde, Gunvor
2018-04-01
Today all healthy pregnant women are encouraged to be physically active throughout pregnancy, with recommendations to participate in at least 30 minutes of aerobic activity on most days of the week in addition to performing strength training of the major muscle groups 2-3 days per week and also pelvic floor muscle training. There is, however, an ongoing debate whether general physical activity enhances or declines pelvic floor muscle function. The objectives of the study were to compare vaginal resting pressure, pelvic floor muscle strength, and endurance in regular exercisers (exercise ≥30 minutes 3 or more times per week) and nonexercisers at midpregnancy. Furthermore, another objective was to assess whether regular general exercise or pelvic floor muscle strength was associated with urinary incontinence. This was a cross-sectional study at mean gestational week 20.9 (±1.4) including 218 nulliparous pregnant women, with a mean age of 28.6 years (range, 19-40 years) and prepregnancy body mass index of 23.9 kg/m 2 (SD, 4.0). Vaginal resting pressure, pelvic floor muscle strength, and pelvic floor muscle endurance were measured by a high-precision pressure transducer connected to a vaginal balloon. The International Consultation on Incontinence Questionnaire Urinary Incontinence Short Form was used to assess urinary incontinence. Differences between groups were analyzed using an independent-sample Student t test. Linear regression analysis was conducted to adjust for prepregnancy body mass index, age, smoking during pregnancy, and regular pelvic floor muscle training during pregnancy. The significance value was set to P ≤ .05. Regular exercisers had statistically significant stronger (mean 6.4 cm H 2 O [95% confidence interval, 1.7-11.2]) and more enduring (mean 39.9 cm H 2 Osec [95% confidence interval, 42.2-75.7]) pelvic floor muscles. Only pelvic floor muscle strength remained statistically significant, when adjusting for possible confounders. Pelvic floor muscle strength and not regular general exercise was associated with urinary continence (adjusted B, -6.4 [95% confidence interval, -11.5 to -1.4]). Regular exercisers at midpregnancy have stronger pelvic floor muscles than their sedentary counterparts. However, pelvic floor muscle strength and not regular general exercise was associated with urinary incontinence. There is a need for additional studies in elite athletes and women performing more strenuous exercise regimens. Copyright © 2017 Elsevier Inc. All rights reserved.
Sran, Meena M; Robinovitch, Stephen N
2008-08-01
In vivo biomechanical study of 11 male volunteers. To measure the peak forces applied to the buttocks in a backward fall from standing, and to determine whether this force is lowered by reductions in floor stiffness. Fall-related vertebral fractures are common and backward falls result in impact to the buttocks. Compliant flooring may reduce impact force and risk for vertebral fracture during a fall. However, we have little knowledge of the peak forces applied to the body during a backward fall, or how floor stiffness affects this force. Eleven males, mean age 25 +/- 5 (SD) years, were suddenly released from a backward lean of 15 degrees , falling backward onto the ground which was covered with 4.5, 7.5, or 10.5 cm of ethylene vinyl acetate foam rubber. We measured 3-dimensional impact forces applied to the buttocks at 960 Hz with a force plate. We used repeated measures analysis of variance and post hoc t tests to compare peak forces between conditions. We also modeled peak vertical force for falls onto a bare floor. RESULTS.: There was a significant difference in peak vertical force between falls onto the 10.5 cm foam condition compared with the 7.5 cm (P = 0.002) and 4.5 cm (P < 0.001) conditions. Peak vertical force (N) was (mean +/- SD) 5099 +/- 868, 4788 +/- 702, and 4544 +/- 672 for the 4.5, 7.5, and 10.5 cm foam conditions, respectively, and estimated at 6027 +/- 988 for the rigid (bare floor) condition. Compared with the bare floor, these foam floors provided, on average, 24, 20, and 15% force attenuation respectively. In a backward fall onto the buttocks, peak impact forces are 6.4 to 9.0 times body weight in a fall onto a bare floor. Reducing floor stiffness using even a thin (4.5 cm) layer of foam may provide 15% vertical force attenuation during a fall onto the buttocks.
Indoor air quality and health problems associated with damp floor coverings.
Tuomainen, Anneli; Seuri, Markku; Sieppi, Anne
2004-04-01
To study the relationship between a high incidence of bronchial asthma among employees working in an office building and an indoor air problem related to the degradation of polyvinyl chloride (PVC) floor coverings in the building. The indoor air measurements and results of renovations are also described. Employees' symptoms were surveyed by a questionnaire, and the incidence of asthma was calculated from the medical records for 1997-2000. The quality of indoor air was assessed by microbial sampling and by investigation of the building for possible moisture damage. Indoor air was sampled for volatile organic compounds (VOCs) through Tenax adsorbent tubes. In situ volatile emission measurements from the concrete floor were performed via the field and laboratory emission cell (FLEC) method. In an office with approximately 150 employees, eight new cases of asthma were found in 4 years. In addition, the workers complained of respiratory, conjunctival and nasal symptoms. Emissions indicating the degradation of plastic floor coverings (e.g. 2-ethyl-1-hexanol, 1-butanol) were found in the indoor air and floor material samples. The plastic floor coverings, adhesives and the levelling layers were carefully removed from 12 rooms. The VOCs had diffused into the underlying concrete slabs. The concrete was warmed to remove the diffused VOCs from these areas. After the repairs the concentrations of the VOCs indicating the degradation of PVC, decreased, as did the prevalence of the employees' symptoms and several asthma patients' need for medication. The workers in the office building complained of several respiratory, conjunctival and dermal symptoms. The incidence of adult-onset asthma was approximately nine-times higher than that among Finns employed in similar work. The most probable single cause of the indoor air problem was the degradation of the plastic floor coverings.
32. INTERIOR VIEW TO THE NORTH OF THE FIRST FLOOR ...
32. INTERIOR VIEW TO THE NORTH OF THE FIRST FLOOR EAST CORRIDOR AND VIEWING GALLERY TO THE DISASSEMBLY BAY. A VIEWING AND WORK STATION FOR THE EAST SIDE OF THE UPPER LEVEL OF THE DISASSEMBLY BAY IS ON THE WEST SIDE OF THE CORRIDOR. - Nevada Test Site, Reactor Maintenance Assembly & Dissassembly Facility, Area 25, Jackass Flats, Junction of Roads F & G, Mercury, Nye County, NV
Instrumentation and control building, architectural, floor plans. Specifications no. Eng-04-353-55-72; Drawing No. 60-09-12' sheet 64 of 148; file no. 1321/15. Stamped: record drawing - as constructed. Below stamp: Contract no. 4338, no change. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Control Center, Test Area 1-115, near Altair & Saturn Boulevards, Boron, Kern County, CA
Cell phone radiation effects on cytogenetic abnormalities of oral mucosal cells.
Daroit, Natália Batista; Visioli, Fernanda; Magnusson, Alessandra Selinger; Vieira, Geila Radunz; Rados, Pantelis Varvaki
2015-01-01
The aim of this study was to evaluate the effects of exposure to cell phone electromagnetic radiation on the frequency of micronuclei, broken eggs cells, binucleated cells, and karyorrhexis in epithelial cells of the oral mucosa. The sample was composed of 60 cell phone users, who were non-smokers and non-drinkers, and had no clinically visible oral lesions. Cells were obtained from anatomical sites with the highest incidence of oral cancer: lower lip, border of the tongue, and floor of the mouth. The Feulgen reaction was used for quantification of nuclear anomalies in 1,000 cells/slide. A slightly increase in the number of micronucleated cells in the lower lip and in binucleated cells on the floor of the mouth was observed in individuals who used their phones > 60 minutes/week. The analysis also revealed an increased number of broken eggs in the tongue of individuals owning a cell phone for over eight years. Results suggest that exposure to electromagnetic waves emitted by cell phones can increase nuclear abnormalities in individuals who use a cell phone for more than 60 minutes per week and for over eight years. Based on the present findings, we suggest that exposure to electromagnetic radiation emitted by cell phones may interfere with the development of metanuclear anomalies. Therefore, it is demonstrated that, despite a significant increase in these anomalies, the radiation emitted by cell phones among frequent users is within acceptable physiological limits.
Zhang, Yong; Wang, Zhen-Ning; He, Lei; Gao, Ge; Zhai, Qing; Yin, Zhi-Tao; Zeng, Xian-Dong
2014-01-01
AIM: To evaluate the efficacy of botulinum toxin type A injection to the puborectalis and external sphincter muscle in the treatment of patients with anismus unresponsive to simple biofeedback training. METHODS: This retrospective study included 31 patients suffering from anismus who were unresponsive to simple biofeedback training. Diagnosis was made by anorectal manometry, balloon expulsion test, surface electromyography of the pelvic floor muscle, and defecography. Patients were given botulinum toxin type A (BTX-A) injection and pelvic floor biofeedback training. Follow-up was conducted before the paper was written. Improvement was evaluated using the chronic constipation scoring system. RESULTS: BTX-A injection combined with pelvic floor biofeedback training achieved success in 24 patients, with 23 maintaining persistent satisfaction during a mean period of 8.4 mo. CONCLUSION: BTX-A injection combined with pelvic floor biofeedback training seems to be successful for intractable anismus. PMID:25253964
Dolman, M; Chase, J
1996-08-01
A small-scale study was undertaken to test the relative predictive power of the Health Belief Model and Subjective Expected Utility Theory for the uptake of a behaviour (pelvic floor exercises) to reduce post-partum urinary incontinence in primigravida females. A structured questionnaire was used to gather data relevant to both models from a sample antenatal and postnatal primigravida women. Questions examined the perceived probability of becoming incontinent, the perceived (dis)utility of incontinence, the perceived probability of pelvic floor exercises preventing future urinary incontinence, the costs and benefits of performing pelvic floor exercises and sources of information and knowledge about incontinence. Multiple regression analysis focused on whether or not respondents intended to perform pelvic floor exercises and the factors influencing their decisions. Aggregated data were analysed to compare the Health Belief Model and Subjective Expected Utility Theory directly.
Zhang, Yong; Wang, Zhen-Ning; He, Lei; Gao, Ge; Zhai, Qing; Yin, Zhi-Tao; Zeng, Xian-Dong
2014-09-21
To evaluate the efficacy of botulinum toxin type A injection to the puborectalis and external sphincter muscle in the treatment of patients with anismus unresponsive to simple biofeedback training. This retrospective study included 31 patients suffering from anismus who were unresponsive to simple biofeedback training. Diagnosis was made by anorectal manometry, balloon expulsion test, surface electromyography of the pelvic floor muscle, and defecography. Patients were given botulinum toxin type A (BTX-A) injection and pelvic floor biofeedback training. Follow-up was conducted before the paper was written. Improvement was evaluated using the chronic constipation scoring system. BTX-A injection combined with pelvic floor biofeedback training achieved success in 24 patients, with 23 maintaining persistent satisfaction during a mean period of 8.4 mo. BTX-A injection combined with pelvic floor biofeedback training seems to be successful for intractable anismus.
Photographic copy of floor plans for Bachelor Officers' Quarters (Tl) ...
Photographic copy of floor plans for Bachelor Officers' Quarters (T-l) known as the "Desert Rat Hotel" in the early days of the Muroc Flight Test Base (North Base). The plans show the layout of quarters, lavatories, mess as well as, the cooling system installation. Contract W-509-Eng 2937, Military Construction; Muroc Bombing Range, Muroc Lake, Calif; Materiel Test Site, Officers Quarters, Evaporative Coolers, Sheet 5 of 11, May 1942. Reproduced from the holdings of the National Archives, Pacific Southwest Region - Edwards Air Force Base, North Base, Bachelor Officers' Quarters T-1, Second & C Streets, Boron, Kern County, CA
ETR, TRA642, CAMERA IS BELOW, BUT NEAR THE CEILING OF ...
ETR, TRA-642, CAMERA IS BELOW, BUT NEAR THE CEILING OF THE GROUND FLOOR, AND LOOKS DOWN TOWARD THE CONSOLE FLOOR. CAMERA FACES WESTERLY. THE REACTOR PIT IS IN THE CENTER OF THE VIEW. BEYOND IT TO THE LEFT IS THE SOUTH SIDE OF THE WORKING CANAL. IN THE FOREGROUND ON THE RIGHT IS THE SHIELDING FOR THE PROCESS WATER TUNNEL AND PIPING. SPIRAL STAIRCASE AT LEFT OF VIEW. INL NEGATIVE NO. 56-2237. Jack L. Anderson, Photographer, 7/6/1956 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Wang, Fang; Li, Qiong; Wang, Zuolin
2017-08-01
To compare the effects of Bio-Oss ® in combination with concentrated growth factors (CGFs) and bone marrow-derived mesenchymal stem cells (BMSCs) on bone regeneration for maxillary sinus floor augmentation in beagle dogs. Six beagle dogs received bilateral maxillary sinus floor augmentation. Venous blood drawn from dogs was collected and centrifuged to obtain CGFs. BMSCs derived from canine bone marrow were cultured using density gradient centrifugation. The suspension of BMSCs was added onto Bio-Oss ® granules at a density of 2 × 10 6 cells/ml, and the BMSCs/Bio-Oss ® constructs were incubated for an additional 4 h before use. Twelve sinuses were grafted with a mixture of CGFs/Bio-Oss ® , BMSCs/Bio-Oss ® construct, or Bio-Oss ® alone. Six months later, the bone formation of bilateral sinuses was evaluated by Micro-CT, microhardness test, histological examination, and histomorphometry. No adverse effect was found in these dogs. The dome-shaped augmentation protruded into the sinus cavity. Micro-CT revealed that there was significant difference in BV/TV but not in Tb. N, between groups A, B, and C. The extent of microhardness in groups A and B was significantly higher than in group C. The proportion of newly formed bone in groups A and B showed significant difference when compared to group C (P ≤ 0.01). The amount of residual grafts in groups A and B was significantly lower than in group C. Grafting with Bio-Oss ® in combination with CGFs can increase new bone formation more efficiently than using Bio-Oss ® alone in a canine model. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
How does horizontal and vertical navigation influence spatial memory of multifloored environments?
Thibault, Guillaume; Pasqualotto, Achille; Vidal, Manuel; Droulez, Jacques; Berthoz, Alain
2013-01-01
Although a number of studies have been devoted to 2-D navigation, relatively little is known about how the brain encodes and recalls navigation in complex multifloored environments. Previous studies have proposed that humans preferentially memorize buildings by a set of horizontal 2-D representations. Yet this might stem from the fact that environments were also explored by floors. Here, we have investigated the effect of spatial learning on memory of a virtual multifloored building. Two groups of 28 participants watched a computer movie that showed either a route along floors one at a time or travel between floors by simulated lifts, consisting in both cases of a 2-D trajectory in the vertical plane. To test recognition, the participants viewed a camera movement that either replicated a segment of the learning route (familiar segment) or did not (novel segment-i.e., shortcuts). Overall, floor recognition was not reliably superior to column recognition, but learning along a floor route produced a better spatial memory performance than did learning along a column route. Moreover, the participants processed familiar segments more accurately than novel ones, not only after floor learning, but crucially, also after column learning, suggesting a key role of the observation mode on the exploitation of spatial memory.
A pilot study on the improvement of the lying area of finishing pigs by a soft lying mat.
Savary, Pascal; Gygax, Lorenz; Jungbluth, Thomas; Wechsler, Beat; Hauser, Rudolf
2011-01-01
In this pilot study, we tested whether a soft mat (foam covered with a heat-sealed thermoplastic) reduces alterations and injuries at the skin and the leg joints.The soft mat in the lying area of partly slatted pens was compared to a lying area consisting of either bare or slightly littered (100 g straw per pig and day) concrete flooring. In this study we focused on skin lesions on the legs of finishing pigs as indicators of impaired welfare. Pigs were kept in 19 groups of 8-10 individuals and were examined for skin lesions around the carpal and tarsal joints either at a weight of <35 kg, or at close to 100 kg. The likelihood of hairless patches and wounds at the tarsal joints was significantly lower in pens with the soft lying mat than in pens with a bare concrete floor. Pens with a littered concrete floor did not differ compared to pens with a bare concrete floor. The soft lying mat thus improved floor quality in the lying area in terms of preventing skin lesions compared to bare and slightly littered concrete flooring. Such soft lying mats have thus the potential to improve lying comfort and welfare of finishing pigs.
Wagner, Jason M; Conrad, Rachel D; Cannon, Trinitia Y; Alleman, Anthony M
2016-05-01
Limited data exist regarding the feasibility of ultrasound-guided transcutaneous biopsy of the base of the tongue and floor of the mouth. This retrospective study reviewed 8 cases with lesions in the base of the tongue or floor of the mouth that were biopsied by fine-needle aspiration. Core biopsy was also needed in 1 case. All biopsies were technically successful, and all yielded squamous cell carcinoma. One biopsy yielded a false-positive result, as subsequent resection yielded high-grade dysplasia with no invasion. The other biopsy results were considered true-positive based on subsequent pathologic examinations (2 cases) or clinical/imaging follow-up (5 cases). There were no significant complications associated with the biopsies. © 2016 by the American Institute of Ultrasound in Medicine.
Cancer - mouth; Mouth cancer; Head and neck cancer - oral; Squamous cell cancer - mouth; Malignant neoplasm - oral ... Oral cancer most commonly involves the lips or the tongue. It may also occur on the: Cheek lining Floor ...
Abd El-Wahab, A; Beineke, A; Beyerbach, M; Visscher, C F; Kamphues, J
2011-09-01
Actions concerning animal health in turkey production are coming more and more to the fore. Litter quality has a great impact on the bird's health and welfare. This study aimed at evaluating the effects of using floor heating, different litter materials, and exposure to litter with a "critical moisture content" of 35% for 16 or 24 hr/day on the severity of foot pad dermatitis (FPD), a widespread disease in fattening turkeys. Four groups of 2-wk-old female turkeys, with 20 birds in each, were reared during 3 wk. All turkeys were fed a commercial pellet diet ad libitum. The first two groups were kept on wood shavings (35% moisture) without and with floor heating. The other two groups were housed on lignocellulose (Soft Cell) of 35% moisture without and with floor heating. In each group, half of the birds were housed for 8 hr/day in adjacent separate boxes where the litter was kept clean and dry throughout the experimental period. Foot pads were assessed weekly for external and at day 35 for histopathologic scoring (scores: 0 = healthy; 7 = ulcer). At day 14 each bird had normal and healthy foot pads. The results indicate that using floor heating resulted in significantly lower FPD scores (0.8 +/- 0.2) compared to groups without floor heating (2.0 +/- 0.8). Using lignocellulose as a litter material resulted in significantly lower histopathologic FPD scores (1.4 +/- 0.7) compared with wood shavings (1.7 +/- 0.8). In all birds housed on dry litter for 8 hr/day, significantly lower FPD scores were found compared to birds housed on wet litter for 24 hr. In conclusion, using floor heating, even with wet litter (35% moisture), independent of the litter type, resulted in reduced severity of FPD compared to those birds housed in pens without using floor heating. Additionally, using lignocellulose as a litter material resulted in lower FPD compared with wood shavings. Keeping litter dry and "warm" could be achieved by using floor heating, which is considered a practical step to enhance animal health and welfare.
Neurophysiological testing in anorectal disorders
Remes-Troche, Jose M; Rao, Satish SC
2013-01-01
Neurophysiological tests of anorectal function can provide useful information regarding the integrity of neuronal innervation, as well as neuromuscular function. This information can give insights regarding the pathophysiological mechanisms that lead to several disorders of anorectal function, particularly fecal incontinence, pelvic floor disorders and dyssynergic defecation. Currently, several tests are available for the neurophysiological evaluation of anorectal function. These tests are mostly performed on patients referred to tertiary care centers, either following negative evaluations or when there is lack of response to conventional therapy. Judicious use of these tests can reveal significant and new understanding of the underlying mechanism(s) that could pave the way for better management of these disorders. In addition, these techniques are complementary to other modalities of investigation, such as pelvic floor imaging. The most commonly performed neurophysiological tests, along with their indications and clinical utility are discussed. Several novel techniques are evolving that may reveal new information on brain–gut interactions. PMID:19072383
6. Historic American Buildings Survey Nathaniel R. Ewan, Photographer March ...
6. Historic American Buildings Survey Nathaniel R. Ewan, Photographer March 3, 1937 INTERIOR - MURDERER'S CELL - SECOND FLOOR - Burlington County Prison, 128 High Street, Mount Holly, Burlington County, NJ
Shan, Le-Qun; Skaggs, David L; Lee, Christopher; Kissinger, Catherine; Myung, Karen S
2013-04-03
Patients undergoing posterior spinal instrumentation and fusion surgery for adolescent idiopathic scoliosis were admitted to the intensive care unit until two years ago, at which time we changed our protocol to admit these patients to the general hospital floor following a brief stay in a postanesthesia care unit. This study compared postoperative management on a hospital floor with that in the intensive care unit for patients with adolescent idiopathic scoliosis undergoing posterior spinal fusion. A retrospective review of 124 consecutive patients with adolescent idiopathic scoliosis treated with spinal fusion from August 2007 to August 2010 was performed. Inclusion criteria were a diagnosis of adolescent idiopathic scoliosis and posterior spinal instrumentation and fusion surgery. Of 124 patients, sixty-six were managed postoperatively in the intensive care unit and fifty-eight, on the hospital floor. The mean age at the time of surgery was fourteen years. A mean of eleven vertebral levels (range, six to fifteen levels) were fused. No significant difference between the groups was found with respect to the mean age at the time of surgery, mean weight, mean preoperative and postoperative Cobb angles, and mean number of levels fused (p ≥ 0.12). However, the use of analgesic and antianxiety medication, number of postoperative blood tests, days of hospital stay, and number of physical therapy sessions were significantly decreased in the floor group compared with the intensive care unit group (p ≤ 0.05). No patient from the floor group had to be admitted to the intensive care unit. The mean charge was $33,121 for the floor group and $39,252 for the intensive care unit group (p < 0.001). Initial postoperative management of patients with adolescent idiopathic scoliosis following a posterior spinal instrumentation and fusion surgery on a general hospital floor, rather than in an intensive care unit, was associated with a shorter hospital stay, fewer blood tests, less analgesic and antianxiety medication usage, and fewer physical therapy sessions at this high-volume, academic, tertiary-care children's hospital. In addition to improved patient outcomes, there was a significant decrease of 16% in hospital charges for the group that did not go to the intensive care unit.
A&M. TAN607 third floor plan for hot shop. Crane control ...
A&M. TAN-607 third floor plan for hot shop. Crane control rooms and their shielding windows. Plenum. Wall rack for manipulators in hot shop. Ralph M. Parsons 902-3-ANP-607-A 103. Date: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 034-0607-00-693-106755 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
Yaşar, Levent; Telci, Serpil Ortakuz; Doğan, Keziban; Kaya, Eyüp; Ekin, Murat
2018-05-19
To investigate the role of measuring the thickness of pelvic floor muscles with static MRI in the physiopathology of urinary incontinence in women with stress and mixed types of urinary incontinence diagnosed with urodynamic studies. A retrospective clinical study was designed in collaboration with the radiology department. We recruited only patients who had undergone static pelvic MRI to determine the etiology of pelvic pain and exclude gynecologic disorders. The study included 45 women diagnosed with stress or mixed-type urinary incontinence based on pelvic examination and urodynamic testing without symptomatic pelvic organ prolapse and 40 continent controls. We evaluated the images of pelvic static MRI of all patients to measure the thickness of the pelvic floor muscles with the radiologist by using an image analysis workstation retrospectively. The right and left puborectalis parts of levator ani muscle thicknesses were significantly lower in the urinary incontinence group than in the control group (p < 0.01). The right and left PR/OI ratios were significantly lower than in the control group. (p = 0.001). Morphologic changes of pelvic floor muscle thickness can be demonstrated by a static pelvic MRI, and this can be used as a prognostic test in the treatment and follow-up of patients with stress or mixed urinary incontinence.
de Assis, Liamara Cavalcante; Bernardes, João Marcos; Barbosa, Angélica Mércia Pascon; Santini, Ana Carolina Monteiro; Vianna, Luana Schneider; Dias, Adriano
2015-10-01
To evaluate the effectiveness of an illustrated home exercise guide targeting the pelvic floor muscles in promoting urinary continence during pregnancy. A randomized clinical trial was performed with 87 participants, evaluated six times during pregnancy and divided into three groups: Gsup, supervised; Gobs, not supervised, and Gref, women who did not perform the home exercises program. A miction diary and perineometry were used to evaluate urinary incontinence (primary outcome) and pelvic floor muscle strength (secondary outcome), respectively. The Kruskal-Wallis test with post hoc Dunn's and chi-square and Z tests with Bonferroni correction were used for continuous variables and proportions, respectively, with the level of significance set at 5%. At the end of the study, 6.9% of pregnant women in the Gsup and Gobs had urinary incontinence, while 96.6% of Gref women were incontinent. Regarding pelvic floor muscle function, Gsup and Gobs had mean contractions of 10 and 8.9 cmH2O, respectively, while Gref had a value of 4.7 cmH2O. Both results were significant. An illustrated home exercise guide targeting the pelvic floor muscles is effective in promoting urinary continence during pregnancy, even without permanent supervision. clinicaltrials.gov Registry--NCT00740428.
A hemangioma on the floor of the mouth presenting as a ranula.
Skoulakis, Charalampos E; Khaldi, Lubna; Serletis, Demetre; Semertzidis, Themistoklis
2008-11-01
A painless, bluish, submucosal swelling on one side of the floor of the mouth usually indicates the presence of a ranula. Rarely, such a swelling may be caused by an inflammatory disease process in a salivary gland, a neoplasm in the sublingual salivary gland, a lymphatic nodular swelling, or embryologic cysts. We report a patient with swelling in the floor of her mouth that was clinically diagnosed as a ranula. Suspicion arose during surgery that it was a vascular tumor and, on histologic testing, the swelling was confirmed to be a hemangioma. To our knowledge, this is the first report in the literature of a hemangioma presenting as a ranula.
Hackney, James; Brummel, Sara; Newman, Mary; Scott, Shannon; Reinagel, Matthew; Smith, Jennifer
2015-09-01
We carried out a study to investigate how low stiffness flooring may help prevent overuse injuries of the lower extremity in dancers. It was hypothesized that performing a ballet jump (sauté) on a reduced stiffness dance floor would decrease maximum joint flexion angles and negative angular velocities at the hips, knees, or ankles compared to performing the same jump on a harder floor. The participants were 15 young adult female dancers (age range 18 to 28, mean = 20.89 ± 2.93 years) with at least 5 years of continuous ballet experience and without history of serious lower body injury, surgery, or recent pain. They performed sautés on a (low stiffness) Harlequin ® WoodSpring Floor and on a vinyl-covered hardwood on concrete floor. Maximum joint flexion angles and negative velocities at bilateral hips, knees, and ankles were measured with the "Ariel Performance Analysis System" (APAS). Paired one-tailed t-tests yielded significant decreases in maximum knee angle (average decrease = 3.4° ± 4.2°, p = 0.026) and angular negative velocity of the ankles (average decrease = 18.7°/sec ± 27.9°/sec, p = 0.009) with low stiffness flooring. If the knee angle is less acute, then the length of the external knee flexion moment arm will also be shorter and result in a smaller external knee flexion moment, given an equal landing force. Also, high velocities of eccentric muscle contraction, which are necessary to control negative angular velocity of the ankle joint, are associated with higher risk of musculotendinous injury. Hence, our findings indicate that reduced floor stiffness may indeed help decrease the likelihood of lower extremity injuries.
Noorafshan, Ali; Karimi, Fatemeh; Kamali, Ali-Mohammad; Karbalay-Doust, Saied; Nami, Mohammad
2017-11-15
The present study examined the consequences of rapid eye-movement sleep-deprivation (REM-SD) with or without curcumin treatment. The outcome measures comprised quantitative features in the three-dimensional reconstruction (3DR) CA1 and dentate gyrus in experimental and control animals using stereological procedures. Male rats were arbitrarily assigned to nine groups based on the intervention and treatment administered including: 1-cage control+distilled water, 2-cage control+curcumin (100mg/kg/day), 3-cage control+olive oil, 4-REM-SD+distilled water, 5-REM-SD+curcumin, 6-REM-SD+olive oil, 7-grid-floor control+distilled water, 8-grid-floor control+curcumin, and 9-grid-floor control+olive oil. Animals in the latter three groups were placed on wire-mesh grids in the sleep-deprivation box. REM-SD was induced by an apparatus comprising a water tank and multiple platforms. After a period of 21days, rats were submitted to the novel object-recognition task. Later, their brains were excised and evaluated using stereological methods. Our results indicated a respective 29% and 31% reduction in the total volume of CA1, and dentate gyrus in REM-SD+distilled water group as compared to the grid-floor control+distilled water group (p<0.05). Other than the above, the overall number of the pyramidal cells of CA1 and granular cells of dentate gyrus in the sleep-deprived group were found to be reduced by 48% and 25%, respectively. The REM-SD+distilled water group also exhibited impaired object recognition memory and deformed three-dimensional reconstructions of these regions. The volume, cell number, reconstruction, object recognition time, and body weight were however recovered in the REM-SD+curcumin compared to the REM-SD+distilled water group. This suggests the potential neuro-restorative effects of curcumin in our model. Copyright © 2017 Elsevier Inc. All rights reserved.
Emergency evacuation tests of a crashed L-1649.
DOT National Transportation Integrated Search
1966-08-01
Four basic evacuation tests were performed on a crashed L-1649 in Phoenix, Arizona, to document problem areas, passenger reaction, emergency lighting, slope of flooring and other items affecting passenger egress. Two day and two night tests were run ...
NASA Astrophysics Data System (ADS)
Redsven, I.; Kymäläinen, H.-R.; Pesonen-Leinonen, E.; Kuisma, R.; Ojala-Paloposki, T.; Hautala, M.; Sjöberg, A.-M.
2007-04-01
Detection of adenosine triphosphate (ATP) by bioluminescence is used, for instance, in the food industry and in hospitals to assess the hygiene status of surfaces. The aim of this laboratory study was to investigate the feasibility of the ATP method for estimating the cleanability of resilient floor coverings from biological soil. The surfaces were worn using a Soiling and Wearing Drum Tester, and soiled and cleaned with an Erichsen Washability and Scrubbing Resistance Tester. In the laboratory test carried out with the bioluminescence method, most of the new and worn floor coverings that were biologically soiled were cleaned efficiently. According to this study, the semiquantitative ATP screening method can be used for hygiene monitoring of flooring materials. No correlation was found between cleanability and contact angles or surface topography measured using a profilometer. However, by revealing local irregularities and damage on surfaces, scanning electron micrographs appeared useful in explaining differences in cleanability.
The Feasibility of Sugar Palm (Arenga pinnata) Trunk for Raw Material of Parquet (Wood Flooring)
NASA Astrophysics Data System (ADS)
Nuryawan, A.; Tarigan, A.; Hakim, L.
2017-03-01
In the market, parquet was made from high density wood such as teak, merbau, kempas, ulin, oak, lime, maple, or other high density wood. Parquet has been used for flooring in specific buildings, for instance sport hall, library, commercial building (i.e hotel lobby, hypermarket), and office building. Because of the scarcity of high density wood nowadays and in order to find out the alternative material for wood flooring, the utilization of sugar palm trunk was considered. In this contribution, unproductive sugar palm tree was cut down and divided into three sections using chain saw, namely bottom, middle, and tip. For each section, physical and mechanical samples testing were made according to British Standard 373:1957 for small clear specimen. Investigation of both properties was done in ambient temperature with at least three replications. Instron UTM (Universal Testing Machine) was used to evaluate the mechanical properties. Results of the physical testing (density, moisture content and tangential shrinkage) showed the entire trunk was suitable for raw material of parquet. However, the results of mechanical testing (hardness, MOE/modulus of elasticity, MOR/modulus of rupture, and compression perpendicular to grain) showed only bottom and middle parts were suitable for raw material of parquet while the upper part was vice versa.
Eicher, S D; Lay, D C; Arthington, J D; Schutz, M M
2013-06-01
Some housing systems on dairy farms can result in long-term chronic pain. The effects of acute pain on immunity have been explored, but chronic pain's influence on immune responses is still poorly understood. Therefore, the objective of this research was to determine chronic effects of flooring on immune responses and production in freestall housing for dairy cows. Thirty heifers were studied from before calving as first-calf heifers until d 180 of their second lactation. Treatments were rubber (Kraiburg; Agromatic Inc., Fond du Lac, WI) flooring or concrete with diamond grooves in a freestall barn, each in 2 quadrants of the barn. Heifers entered the treatments after calving, so the system was dynamic and each cow was considered an experimental unit. At the end of the first lactation, cows were housed in a bedded pack barn with pasture access until calving was imminent. At that time, they returned to their assigned treatment, but not necessarily into the same quadrant. Production, reproduction, cortisol, acute-phase proteins, and health data were recorded throughout lactation 1, locomotion was scored weekly, and hoof scoring and care was conducted on d 60 and 180 of lactations 1 and 2, and quantitative real-time-PCR of blood leukocytes was analyzed in mid lactation of lactation 1. Mature-equivalent milk fat, milk protein, and protein percentages during the first lactation were greater for cows on the rubber flooring. Hoof and leg therapy treatments per cow were fewer for rubber floor-housed cows. Locomotion scores were less for cows housed on rubber during the second lactation. White blood cell counts were less for cows housed on rubber, and caused by greater lymphocyte counts for cows housed on concrete. The possibility of chronic inflammation was substantiated by less IL-1β and more IL-1 receptor antagonists for cows housed on rubber at d 150 in the second lactation. Cortisol and acute-phase proteins did not differ between the treatments. Interferon-γ, IL-12, the modulator of tissue reconstruction (B-cell-transforming growth factor 1), and pain-modulating neurokinin (tachykinin 1) were not different at d 105. These data show indicators of chronic inflammation for cows housed on the concrete flooring compared with those housed on rubber. Implications for the use of rubber flooring in freestall barns are broader than just lameness and may affect many aspects of cow physiology and production. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Virtual reality: new method of teaching anorectal and pelvic floor anatomy.
Dobson, Howard D; Pearl, Russell K; Orsay, Charles P; Rasmussen, Mary; Evenhouse, Ray; Ai, Zhuming; Blew, Gregory; Dech, Fred; Edison, Marcia I; Silverstein, Jonathan C; Abcarian, Herand
2003-03-01
A clear understanding of the intricate spatial relationships among the structures of the pelvic floor, rectum, and anal canal is essential for the treatment of numerous pathologic conditions. Virtual-reality technology allows improved visualization of three-dimensional structures over conventional media because it supports stereoscopic-vision, viewer-centered perspective, large angles of view, and interactivity. We describe a novel virtual reality-based model designed to teach anorectal and pelvic floor anatomy, pathology, and surgery. A static physical model depicting the pelvic floor and anorectum was created and digitized at 1-mm intervals in a CT scanner. Multiple software programs were used along with endoscopic images to generate a realistic interactive computer model, which was designed to be viewed on a networked, interactive, virtual-reality display (CAVE or ImmersaDesk). A standard examination of ten basic anorectal and pelvic floor anatomy questions was administered to third-year (n = 6) and fourth-year (n = 7) surgical residents. A workshop using the Virtual Pelvic Floor Model was then given, and the standard examination was readministered so that it was possible to evaluate the effectiveness of the Digital Pelvic Floor Model as an educational instrument. Training on the Virtual Pelvic Floor Model produced substantial improvements in the overall average test scores for the two groups, with an overall increase of 41 percent (P = 0.001) and 21 percent (P = 0.0007) for third-year and fourth-year residents, respectively. Resident evaluations after the workshop also confirmed the effectiveness of understanding pelvic anatomy using the Virtual Pelvic Floor Model. This model provides an innovative interactive educational framework that allows educators to overcome some of the barriers to teaching surgical and endoscopic principles based on understanding highly complex three-dimensional anatomy. Using this collaborative, shared virtual-reality environment, teachers and students can interact from locations world-wide to manipulate the components of this model to achieve the educational goals of this project along with the potential for virtual surgery.
78 FR 73512 - Privacy Act of 1974; System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-06
... Center Drive, East Tower, 2nd Floor, Suite 02G09, Alexandria, VA 22350-3100. Instructions: All... office telephone/fax/cell phone numbers, and email address.'' * * * * * Routine uses of records...
NASA Astrophysics Data System (ADS)
Hester, David; Brownjohn, James; Bocian, Mateusz; Xu, Yan; Quattrone, Antonino
2018-05-01
This paper explores the use of wireless Inertial Measurement Units (IMU) originally developed for bio-mechanical research applications for modal testing of civil engineering infrastructure. Due to their biomechanics origin, these devices combine a triaxial accelerometer with gyroscopes and magnetometers for orientation, as well as on board data logging capability and wireless communication for optional data streaming and to coordinate synchronisation with other IMUs in a network. The motivation for application to civil structures is that their capabilities and simple operating procedures make them suitable for modal testing of many types of civil infrastructure of limited dimension including footbridges and floors while also enabling recovering of dynamic forces generated and applied to structures by moving humans. To explore their capabilities in civil applications, the IMUs are evaluated through modal tests on three different structures with increasing challenge of spatial and environmental complexity. These are, a full-scale floor mock-up in a laboratory, a short span road bridge and a seven story office tower. For each case, the results from the IMUs are compared with those from a conventional wired system to identify the limitations. The main conclusion is that the relatively high noise floor and limited communication range will not be a serious limitation in the great majority of typical civil modal test applications where convenient operation is a significant advantage over conventional wired systems.
Measurement properties of the Spinal Cord Injury-Functional Index (SCI-FI) short forms.
Heinemann, Allen W; Dijkers, Marcel P; Ni, Pengsheng; Tulsky, David S; Jette, Alan
2014-07-01
To evaluate the psychometric properties of the Spinal Cord Injury-Functional Index (SCI-FI) short forms (basic mobility, self-care, fine motor, ambulation, manual wheelchair, and power wheelchair) based on internal consistency; correlations between short forms banks, full item bank forms, and a 10-item computer adaptive test version; magnitude of ceiling and floor effects; and test information functions. Cross-sectional cohort study. Six rehabilitation hospitals in the United States. Individuals with traumatic spinal cord injury (N=855) recruited from 6 national Spinal Cord Injury Model Systems facilities. Not applicable. SCI-FI full item bank, 10-item computer adaptive test, and parallel short form scores. The SCI-FI short forms (with separate versions for individuals with paraplegia and tetraplegia) demonstrate very good internal consistency, group-level reliability, excellent correlations between short forms and scores based on the total item bank, and minimal ceiling and floor effects (except ceiling effects for persons with paraplegia on self-care, fine motor, and power wheelchair ability and floor effects for persons with tetraplegia on self-care, fine motor, and manual wheelchair ability). The test information functions are acceptable across the range of scores where most persons in the sample performed. Clinicians and researchers should consider the SCI-FI short forms when computer adaptive testing is not feasible. Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Liu, Wen; Fu, Xiao; Deng, Zhongliang
2016-12-02
Indoor positioning technologies has boomed recently because of the growing commercial interest in indoor location-based service (ILBS). Due to the absence of satellite signal in Global Navigation Satellite System (GNSS), various technologies have been proposed for indoor applications. Among them, Wi-Fi fingerprinting has been attracting much interest from researchers because of its pervasive deployment, flexibility and robustness to dense cluttered indoor environments. One challenge, however, is the deployment of Access Points (AP), which would bring a significant influence on the system positioning accuracy. This paper concentrates on WLAN based fingerprinting indoor location by analyzing the AP deployment influence, and studying the advantages of coordinate-based clustering compared to traditional RSS-based clustering. A coordinate-based clustering method for indoor fingerprinting location, named Smallest-Enclosing-Circle-based (SEC), is then proposed aiming at reducing the positioning error lying in the AP deployment and improving robustness to dense cluttered environments. All measurements are conducted in indoor public areas, such as the National Center For the Performing Arts (as Test-bed 1) and the XiDan Joy City (Floors 1 and 2, as Test-bed 2), and results show that SEC clustering algorithm can improve system positioning accuracy by about 32.7% for Test-bed 1, 71.7% for Test-bed 2 Floor 1 and 73.7% for Test-bed 2 Floor 2 compared with traditional RSS-based clustering algorithms such as K-means.
Liu, Wen; Fu, Xiao; Deng, Zhongliang
2016-01-01
Indoor positioning technologies has boomed recently because of the growing commercial interest in indoor location-based service (ILBS). Due to the absence of satellite signal in Global Navigation Satellite System (GNSS), various technologies have been proposed for indoor applications. Among them, Wi-Fi fingerprinting has been attracting much interest from researchers because of its pervasive deployment, flexibility and robustness to dense cluttered indoor environments. One challenge, however, is the deployment of Access Points (AP), which would bring a significant influence on the system positioning accuracy. This paper concentrates on WLAN based fingerprinting indoor location by analyzing the AP deployment influence, and studying the advantages of coordinate-based clustering compared to traditional RSS-based clustering. A coordinate-based clustering method for indoor fingerprinting location, named Smallest-Enclosing-Circle-based (SEC), is then proposed aiming at reducing the positioning error lying in the AP deployment and improving robustness to dense cluttered environments. All measurements are conducted in indoor public areas, such as the National Center For the Performing Arts (as Test-bed 1) and the XiDan Joy City (Floors 1 and 2, as Test-bed 2), and results show that SEC clustering algorithm can improve system positioning accuracy by about 32.7% for Test-bed 1, 71.7% for Test-bed 2 Floor 1 and 73.7% for Test-bed 2 Floor 2 compared with traditional RSS-based clustering algorithms such as K-means. PMID:27918454
Cellular Scale Anisotropic Topography Guides Schwann Cell Motility
Mitchel, Jennifer A.; Hoffman-Kim, Diane
2011-01-01
Directed migration of Schwann cells (SC) is critical for development and repair of the peripheral nervous system. Understanding aspects of motility specific to SC, along with SC response to engineered biomaterials, may inform strategies to enhance nerve regeneration. Rat SC were cultured on laminin-coated microgrooved poly(dimethyl siloxane) platforms that were flat or presented repeating cellular scale anisotropic topographical cues, 30 or 60 µm in width, and observed with timelapse microscopy. SC motion was directed parallel to the long axis of the topography on both the groove floor and the plateau, with accompanying differences in velocity and directional persistence in comparison to SC motion on flat substrates. In addition, feature dimension affected SC morphology, alignment, and directional persistence. Plateaus and groove floors presented distinct cues which promoted differential motility and variable interaction with the topographical features. SC on the plateau surfaces tended to have persistent interactions with the edge topography, while SC on the groove floors tended to have infrequent contact with the corners and walls. Our observations suggest the capacity of SC to be guided without continuous contact with a topographical cue. SC exhibited a range of distinct motile morphologies, characterized by their symmetry and number of extensions. Across all conditions, SC with a single extension traveled significantly faster than cells with more or no extensions. We conclude that SC motility is complex, where persistent motion requires cellular asymmetry, and that anisotropic topography with cellular scale features can direct SC motility. PMID:21949703
Catala, M; Teillet, M A; De Robertis, E M; Le Douarin, M L
1996-09-01
The spinal cord of thoracic, lumbar and caudal levels is derived from a region designated as the sinus rhomboidalis in the 6-somite-stage embryo. Using quail/chick grafts performed in ovo, we show the following. (1) The floor plate and notochord derive from a common population of cells, located in Hensen's node, which is equivalent to the chordoneural hinge (CNH) as it was defined at the tail bud stage. (2) The lateral walls and the roof of the neural tube originate caudally and laterally to Hensen's node, during the regression of which the basal plate anlage is bisected by floor plate tissue. (3) Primary and secondary neurulations involve similar morphogenetic movements but, in contrast to primary neurulation, extensive bilateral cell mixing is observed on the dorsal side of the region of secondary neurulation. (4) The posterior midline of the sinus rhomboidalis gives rise to somitic mesoderm and not to spinal cord. Moreover, mesodermal progenitors are spatially arranged along the rest of the primitive streak, more caudal cells giving rise to more lateral embryonic structures. Together with the results reported in our study of tail bud development (Catala, M., Teillet, M.-A. and Le Douarin, N.M. (1995). Mech. Dev. 51, 51-65), these results show that the mechanisms that preside at axial elongation from the 6-somite stage onwards are fundamentally similar during the complete process of neurulation.
Zijderveld, Steven A; Zerbo, Ilara R; van den Bergh, Johan P A; Schulten, Engelbert A J M; ten Bruggenkate, Chris M
2005-01-01
A prospective human clinical study was conducted to determine the clinical and histologic bone formation ability of 2 graft materials, a beta-tricalcium phosphate (Cerasorb; Curasan, Kleinostheim, Germany) and autogenous chin bone, in maxillary sinus floor elevation surgery. Ten healthy patients underwent a bilateral (n = 6) or unilateral (n = 4) maxillary sinus floor elevation procedure under local anesthesia. In each case, residual posterior maxillary bone height was between 4 and 8 mm. In cases of bilateral sinus floor elevation, the original bone was augmented with a split-mouth design with 100% beta-tricalcium phosphate on the test side and 100% chin bone on the contralateral control side. The unilateral cases were augmented with 100% beta-tricalcium phosphate. After a healing period of 6 months, ITI full body screw-type implants (Straumann, Waldenburg, Switzerland) were placed. At the time of implant surgery, biopsy samples were removed with a 3.5-mm trephine drill. Sixteen sinus floor elevations were performed. Forty-one implants were placed, 26 on the test side and 15 on the control side. The clinical characteristics at the time of implantation differed, especially regarding clinical appearance and drilling resistance. The increase in height was examined radiographically prior to implantation and was found to be sufficient in all cases. After a mean of nearly 1 year of follow-up, no implant losses or failures had occurred. The promising clinical results of the present study and the lack of implant failures are probably mainly the result of requiring an original bone height of at least 4 mm at the implant location. Although autogenous bone grafting is still the gold standard, according to the clinical results, the preimplantation sinus floor elevation procedure used, which involved a limited volume of beta-tricalcium phosphate, appeared to be a clinically reliable procedure in this patient population.
A study of facilities and fixtures for testing of a high speed civil transport wing component
NASA Technical Reports Server (NTRS)
Cerro, J. A.; Vause, R. F.; Bowman, L. M.; Jensen, J. K.; Martin, C. J., Jr.; Stockwell, A. E.; Waters, W. A., Jr.
1996-01-01
A study was performed to determine the feasibility of testing a large-scale High Speed Civil Transport wing component in the Structures and Materials Testing Laboratory in Building 1148 at NASA Langley Research Center. The report includes a survey of the electrical and hydraulic resources and identifies the backing structure and floor hard points which would be available for reacting the test loads. The backing structure analysis uses a new finite element model of the floor and backstop support system in the Structures Laboratory. Information on the data acquisition system and the thermal power requirements is also presented. The study identified the hardware that would be required to test a typical component, including the number and arrangement of hydraulic actuators required to simulate expected flight loads. Load introduction and reaction structure concepts were analyzed to investigate the effects of experimentally induced boundary conditions.
Benefits of automated surface decontamination of a radioiodine ward.
Westcott, Eliza; Broadhurst, Alicia; Crossley, Steven; Lee, Lloyd; Phan, Xuyen; Scharli, Rainer; Xu, Yan
2012-02-01
A floor-washing robot has been acquired to assist physicists with decontamination of radioiodine therapy ward rooms after discharge of the patient at Sir Charles Gairdner Hospital. The effectiveness of the robot in decontaminating the ward has been evaluated. A controlled experiment was performed by deliberately contaminating a polyvinyl chloride flooring offcut with 131I followed by automated decontamination with the robot. The extent of fixed and removable contamination was assessed before and after decontamination by two methods: (1) direct Geiger-Mueller counting and (2) beta-counting wipe tests. Surface contamination was also assessed in situ on the ward by Geiger-Mueller counting and wipe testing. Contamination maps confirmed that contamination was removed rather than spread around by the robot. Wipe testing revealed that the robot was successful in clearing approximately 60-80% of removable contamination. The robotic floor-washing device was considered suitable to provide effective automated decontamination of the radioiodine ward. In addition, the robot affords other benefits: the time spent by the physicists decontaminating the room is greatly reduced offering financial and occupational safety and health benefits. The robot has also found utility in other decontamination applications in the healthcare environment.
NASA Astrophysics Data System (ADS)
Sayanagi, K.; Goto, T.; Harada, M.; Kasaya, T.; Sawa, T.; Nakajima, T.; Isezaki, N.; Takeuchi, A.; Nagao, T.; Matsuo, J.
2009-12-01
It is generally not easy to obtain the fine-scale structure of the oceanic crust with accuracy better than several tens of meters, because the deep sea prevents us from approaching the bottom in most parts of the oceans. The necessity of such detailed information, however, has increased in researches and developments of the ocean floor. For instance, it is essential in development of ocean floor resources like sea-floor hydrothermal deposits and methane hydrate in order to estimate accurate abundance of those resources. Therefore, it is very important to develop some instruments for precise measurements of the oceanic crust. From this standpoint, we have developed new measurement systems for electrical and magnetic explorations by Remotely Operated Vehicle (ROV) and Autonomous Underwater Vehicle (AUV). In our project, the main target is sea-floor hydrothermal deposits. We are working on research and development regarding measurement of the magnetic field with high resolution and high sampling rate, electrical exploration with accurately controlled source signals, electrical exploration tools for shallow and deep targets, versatile instruments of electrical and magnetic explorations with multi-platforms (deep-tow system, ROV, and AUV), comprehensive analyses of electrical, magnetic, acoustic and thermal data, and so on. We finished basic designs of the magnetic and electrical observation systems last year, and we have been manufacturing each instrument. So far, the first test of the magnetic exploration system was carried out in the Kumano Basin during the R/V Yokosuka cruise in July, 2009. In the test, a vector magnetometer on AUV “Urashima” and a scalar magnetometer hung below towing vehicle “Yokosuka Deep-Tow” successfully detected magnetic anomaly produced by an artificial magnetic body set up on the ocean floor. Details will be reported in another paper by Harada, M. et al. in this meeting. In addition, various performance tests will be planned for check and improvement of the observation systems. For instance, the vector magnetometer will be tested over a volcanic island using a helicopter. The electrical exploration system will be also tested using ROV “Kaiko 7000II” off the northeastern part of Japan during the R/V Kairei cruise. We will present the outline and the current state of the project in this presentation. Note that this project has been supported by the Ministry of Education, Culture, Sports, Science & Technology (MEXT).
40. INTERIOR VIEW TO THE SOUTHEAST OF ROOM 302, A ...
40. INTERIOR VIEW TO THE SOUTHEAST OF ROOM 302, A SMALL ISOLATED OFFICE ON THE THIRD FLOOR ON THE EAST SIDE OF THE DISASSEMBLY BAY. A METAL SPIRAL STAIRCASE IS IN THE SOUTHEAST CORNER AND HATCHWAYS ARE IN THE CEILING AND FLOOR TOWARD THE EAST SIDE OF THE ROOM. - Nevada Test Site, Reactor Maintenance Assembly & Dissassembly Facility, Area 25, Jackass Flats, Junction of Roads F & G, Mercury, Nye County, NV
A&M. TAN607 second floor plan for hot shop. Roof of ...
A&M. TAN-607 second floor plan for hot shop. Roof of pool. Viewing window locations. Special equipment room. This drawing was re-drawn to show conditions in 1994. Ralph M. Parsons 902-3-ANP-607-A 101. Date: December 1952. Approved by INEEL Classification Office for public release. INEEL index code no. 034-060-00-693-106753 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
1983-11-01
Securing and fortifying (a) Doors (b) Hallways (c) Stairs (d) Windows (e) Floors (f) Ceilings 3 (g) Unoccupied rooms (h) Basements (i) Upper floors...observed, the instructors were interviewed, and training K was assessed through administration of a multiple-choice test and a Perception of Training...instructing clearing procedures. It would provide the opportunity to both critique and practice, using one structure. A Perception of Training
Farzinmehr, Azizeh; Moezy, Azar; Koohpayehzadeh, Jalil; Kashanian, Maryam
2015-11-01
To determine whether Whole Body Vibration Training (WBVT) is effective at improving pelvic floor muscles strength in women with Stress Urinary Incontinence (SUI). The study was designed as a randomized clinical trial. 43 women with SUI were randomly assigned in two groups; WBVT and Pelvic Floor Muscle Training (PFMT) and received interventions for four weeks. Pelvic floor muscle (PFM) strength, quality of life and incontinence intensity were evaluated. All measurements were conducted pre and post intervention and also after 3 months in all participants. The ANOVA and the independent sample t test were applied respectively to determine the differences in each group and between the groups. This study showed the WBVT protocol in this study was effective in pelvic floor muscles strength similar to PFMT, and also in reducing the severity of incontinence and increasing I-QOL questionnaire score. We found significant differences in each group pre and post intervention (p = 0.0001); but no significant difference in comparison of two groups' outcomes. Also after three-month follow up, there was no significant difference between groups. The findings of this study showed the beneficial effects of WBVT in improving pelvic floor muscles strength and quality of life in patients with urinary incontinence in four-week treatment period and after three months follow up.
Effect of different flooring systems on claw conformation of dairy cows.
Telezhenko, E; Bergsten, C; Magnusson, M; Nilsson, C
2009-06-01
The effect of different flooring surfaces in walking and standing areas on claw conformation, claw horn growth, and wear was studied in 2 experiments during 2 consecutive housing seasons in a research dairy herd of 170 cows. In experiment 1, the flooring systems tested were solid rubber mats, mastic asphalt with and without rubber-matted feed-stalls, and aged concrete slats. In experiment 2, slatted concrete flooring was compared with slatted rubber flooring. The cows were introduced to the respective flooring systems in early lactation and their claws were trimmed before the exposure period. Toe length, toe angle, sole concavity, and claw width, as well as claw growth and wear rates were recorded for lateral and medial claws of the left hind limb. Claw asymmetry calculations were based on these claw measurements and on differences in sole protrusion between lateral and medial soles. Asphalt floors caused shorter toe length and steeper toe angle. They also increased wear on rear claws (5.30 +/- 0.31 and 5.95 +/- 0.33 mm/mo for lateral and medial claw, respectively; LSM +/- SE) and horn growth rate (5.12 +/- 0.36 and 5.83 +/- 0.31 mm/mo of lateral and medial claws, respectively). Rubber mats instead of asphalt in walking areas reduced wear (1.36 +/- 0.19 and 2.02 +/- 0.20 mm/mo for lateral and medial claw, respectively) and claw growth (3.83 +/- 0.23 and 3.94 +/- 0.17 mm/mo for lateral and medial claw, respectively). Rubber-matted feed-stalls together with asphalt walkways decreased claw wear (3.29 +/- 0.31 and 4.10 +/- 0.32 mm/mo for lateral and medial claw, respectively). The concavity of claw soles was reduced on asphalt, especially in the lateral rear claws. Rubber matting in feed-stalls prevented loss of sole concavity compared with asphalt. Claw asymmetry did not differ between flooring systems. While different access to abrasive flooring affected claw conformation, there was no evidence that flooring system influenced the disproportion between lateral and medial claws.
A Monocular Vision Sensor-Based Obstacle Detection Algorithm for Autonomous Robots.
Lee, Tae-Jae; Yi, Dong-Hoon; Cho, Dong-Il Dan
2016-03-01
This paper presents a monocular vision sensor-based obstacle detection algorithm for autonomous robots. Each individual image pixel at the bottom region of interest is labeled as belonging either to an obstacle or the floor. While conventional methods depend on point tracking for geometric cues for obstacle detection, the proposed algorithm uses the inverse perspective mapping (IPM) method. This method is much more advantageous when the camera is not high off the floor, which makes point tracking near the floor difficult. Markov random field-based obstacle segmentation is then performed using the IPM results and a floor appearance model. Next, the shortest distance between the robot and the obstacle is calculated. The algorithm is tested by applying it to 70 datasets, 20 of which include nonobstacle images where considerable changes in floor appearance occur. The obstacle segmentation accuracies and the distance estimation error are quantitatively analyzed. For obstacle datasets, the segmentation precision and the average distance estimation error of the proposed method are 81.4% and 1.6 cm, respectively, whereas those for a conventional method are 57.5% and 9.9 cm, respectively. For nonobstacle datasets, the proposed method gives 0.0% false positive rates, while the conventional method gives 17.6%.
[Vertical distribution of fuels in Pinus yunnanensis forest and related affecting factors].
Wang, San; Niu, Shu-Kui; Li, De; Wang, Jing-Hua; Chen, Feng; Sun, Wu
2013-02-01
In order to understand the effects of fuel loadings spatial distribution on forest fire kinds and behaviors, the canopy fuels and floor fuels of Pinus yunnanensis forests with different canopy density, diameter at breast height (DBH), tree height, and stand age and at different altitude, slope grade, position, and aspect in Southwest China were taken as test objects, with the fuel loadings and their spatial distribution characteristics at different vertical layers compared and the fire behaviors in different stands analyzed. The relationships between the fuel loadings and the environmental factors were also analyzed by canonical correspondence analysis (CCA). In different stands, there existed significant differences in the vertical distribution of fuels. Pinus yunnanensis-Qak-Syzygium aromaticum, Pinus yunnanensis-oak, and Pinus yunnanensis forests were likely to occur floor fire but not crown fire, while Pinus yunnanensis-Platycladus orientalis, Pinus yunnanensis-Keteleeria fortune, and Keteleeria fortune-Pinus yunnanensis were not only inclined to occur floor fire, but also, the floor fire could be easily transformed into crown fire. The crown fuels were mainly affected by the stand age, altitude, DBH, and tree height, while the floor fuels were mainly by the canopy density, slope grade, altitude, and stand age.
Doorbar-Baptist, Stuart; Adams, Roger; Rebbeck, Trudy
2017-04-01
This study documents a protocol designed to evaluate pelvic floor motor control in men with prostate cancer. It also aims to evaluate the reliability of therapists in rating motor control of pelvic floor muscles (PFMs) using real time ultrasound imaging (RUSI) video clips. We further determine predictors of acquiring motor control. Ninety-one men diagnosed with prostate cancer attending a physiotherapy clinic for pelvic floor exercises were taught detailed pelvic floor motor control exercises by a physiotherapist using trans-abdominal RUSI for biofeedback. A new protocol to rate motor control skill acquisition was developed. Three independent physiotherapists assessed motor control skill attainment by viewing RUSI videos of the contractions. Inter-rater reliability was evaluated using intra-class correlation coefficients. Logistic regression analysis was conducted to identify predictors of successful skill attainment. Acquisition of the skill was compared between pre- and post-operative participants using an independent-group t-test. There was good reliability for rating the RUSI video clips (ICC 0.73 (95%CI 0.59-0.82)) for experienced therapists. Having low BMI and being seen pre-operatively predicted motor skill attainment, accounting for 46.3% of the variance. Significantly more patients trained pre-operatively acquired the skill of pelvic floor control compared with patients initially seen post-operatively (OR 11.87, 95%CI 1.4 to 99.5, p = 0.02). A new protocol to evaluate attainment of pelvic floor control in men with prostate cancer can be assessed reliably from RUSI images, and is most effectively delivered pre-operatively.
On buoyancy-driven natural ventilation of a room with a heated floor
NASA Astrophysics Data System (ADS)
Gladstone, Charlotte; Woods, Andrew W.
2001-08-01
The natural ventilation of a room, both with a heated floor and connected to a cold exterior through two openings, is investigated by combining quantitative models with analogue laboratory experiments. The heated floor generates an areal source of buoyancy while the openings allow displacement ventilation to operate. When combined, these produce a steady state in which the air in the room is well-mixed, and the heat provided by the floor equals the heat lost by displacement. We develop a quantitative model describing this process, in which the advective heat transfer through the openings is balanced with the heat flux supplied at the floor. This model is successfully tested with observations from small-scale analogue laboratory experiments. We compare our results with the steady-state flow associated with a point source of buoyancy: for a given applied heat flux, an areal source produces heated air of lower temperature but a greater volume flux of air circulates through the room. We generalize the model to account for the effects of (i) a cooled roof as well as a heated floor, and (ii) an external wind or temperature gradient. In the former case, the direction of the flow through the openings depends on the temperature of the exterior air relative to an averaged roof and floor temperature. In the latter case, the flow is either buoyancy dominated or wind dominated depending on the strength of the pressure associated with the wind. Furthermore, there is an intermediate multiple-solution regime in which either flow regime may develop.
NASA Technical Reports Server (NTRS)
Wolf, Stephen W. D.; Ray, Edward J.
1988-01-01
The unique combination of adaptive wall technology with a contonuous flow cryogenic wind tunnel is described. This powerful combination allows wind tunnel users to carry out 2-D tests at flight Reynolds numbers with wall interference essentially eliminated. Validation testing was conducted to support this claim using well tested symmetrical and cambered airfoils at transonic speeds and high Reynolds numbers. The test section hardware has four solid walls, with the floor and ceiling flexible. The method of adapting/shaping the floor and ceiling to eliminate top and bottom wall interference at its source is outlined. Data comparisons for different size models tested and others in several sophisticated 2-D wind tunnels are made. In addition, the effects of Reynolds number, testing at high lift with associated large flexible wall movements, the uniqueness of the adapted wall shapes, and the effects of sidewall boundary layer control are examined. The 0.3-m TCT is now the most advanced 2-D research facility anywhere.
78 FR 45184 - Privacy Act of 1974; System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-26
...: Federal Docket Management System Office, 4800 Mark Center Drive, East Tower, 2nd Floor, Suite 02G09... and home address, work and home telephone numbers, email address, and cell phone number.'' Authority...
76 FR 67155 - Privacy Act of 1974; System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-31
..., East Tower, 2nd Floor, Suite 02G09, Alexandria, VA 22350-3100. Instructions: All submissions received... address, home phone number, cell phone number, email addresses, rank/ grade, date of rank, nationality...
76 FR 61679 - Privacy Act of 1974; Systems of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-05
... Office, 4800 Mark Center Drive, East Tower, 2nd Floor, Suite 02G09, Alexandria, VA 22350- 3100... Number (SSN), current address, permanent address, phone number, cell phone number, e-mail address, office...
Pregnancy-induced adaptations in intramuscular extracellular matrix of rat pelvic floor muscles
Alperin, Marianna; Kaddis, Timothy; Pichika, Rajeswari; Esparza, Mary C.; Lieber, Richard L.
2017-01-01
BACKGROUND Birth trauma to pelvic floor muscles is a major risk factor for pelvic floor disorders. Intramuscular extracellular matrix determines muscle stiffness, supports contractile component, and shields myofibers from mechanical strain. OBJECTIVE Our goal was to determine whether pregnancy alters extracellular matrix mechanical and biochemical properties in a rat model, which may provide insights into the pathogenesis of pelvic floor muscle birth injury. To examine whether pregnancy effects were unique to pelvic floor muscles, we also studied a hind limb muscle. STUDY DESIGN Passive mechanical properties of coccygeus, iliocaudalis, pubocaudalis, and tibialis anterior were compared among 3-month old Sprague–Dawley virgin, late-pregnant, and postpartum rats. Muscle tangent stiffness was calculated as the slope of the stress–sarcomere length curve between 2.5 and 4.0 μm, obtained from a stress-relaxation protocol at a bundle level. Elastin and collagen isoform concentrations were quantified by the use of enzyme-linked immunosorbent assay. Enzymatic and glycosylated collagen crosslinks were determined by high-performance liquid chromatography. Data were compared by the use of repeated-measures, 2-way analysis of variance with Tukey post-hoc testing. Correlations between mechanical and biochemical parameters were assessed by linear regressions. Significance was set to P < .05. Results are reported as mean ± SEM. RESULTS Pregnancy significantly increased stiffness in coccygeus (P < .05) and pubocaudalis (P < .0001) relative to virgin controls, with no change in iliocaudalis. Postpartum, pelvic floor muscle stiffness did not differ from virgins (P > .3). A substantial increase in collagen V in coccygeus and pubocaudalis was observed in late-pregnant, compared with virgin, animals, (P < .001). Enzymatic crosslinks decreased in coccygeus (P < .0001) and pubocaudalis (P < .02) in pregnancy, whereas glycosylated crosslinks were significantly elevated in late-pregnant rats in all pelvic floor muscles (P < .05). Correlations between muscle stiffness and biochemical parameters were inconsistent. In contrast to the changes observed in pelvic floor muscles, the tibialis anterior was unaltered by pregnancy. CONCLUSIONS In contrast to other pelvic tissues, pelvic floor muscle stiffness increased in pregnancy, returning to prepregnancy state post-partum. This adaptation may shield myofibers from excessive mechanical strain during parturition. Biochemical alterations in pelvic floor muscle extracellular matrix due to pregnancy include increase in collagen V and a differential response in enzymatic vs glycosylated collagen crosslinks. The relationships between pelvic floor muscle biochemical and mechanical parameters remain unclear. PMID:26875952
Ter Haar, Gert; Hampel, Rachel
2015-10-01
To report a surgical technique for combined rostrolateral rhinotomy (vestibulotomy) and long-term outcome for treatment of squamous cell carcinoma (SCC) of the rostral nasal septum in dogs. Retrospective case series. Medium sized, mixed breed dogs (n = 10), aged 7-12.5 years, with SCC of the rostral nasal septum that did not invade the superficial nasal planum. Disease extent was assessed with computed tomography and tumor resection achieved solely with central nasal planum elevation and lateral rhinotomy. Owners were interviewed 60-2,555 days (median, 548 days) postoperatively to determine outcome and survival time. Vestibulotomy facilitated full-thickness resection of the nasal septum and tumor mass in 10 dogs and nasal floor resection in 4 dogs. There were no major intraoperative complications and all dogs had an excellent cosmetic outcome. Tumor removal was complete in 8 dogs and incomplete in 2 dogs. There was no recurrence in 6 dogs. Of the 4 dogs with recurrence, 3 had required nasal floor resection at initial surgery. A combined rostrolateral rhinotomy technique may be used to achieve complete resection of SCC limited to the nasal septum with acceptable cosmetic results. This technique may not be suitable for tumors extending into the nasal floor. © Copyright 2015 by The American College of Veterinary Surgeons.
Testing of the Anorectal and Pelvic Floor Area
... minutes and is well tolerated by most people. Balloon capacity and compliance A balloon capacity and compliance ... while measurements of volume and pressure are recorded. Balloon evacuation study A balloon evacuation study tests pelvic ...
Impact of pelvic floor muscle training in the postpartum period.
Gagnon, Louise-Helene; Boucher, Jodi; Robert, Magali
2016-02-01
Our study piloted a novel, two-tiered approach to delivering pelvic floor muscle training (PFMT) to postpartum women involving a standardized group workshop followed by the opportunity to self-select for individual PFMT sessions. The aim of the study was to evaluate the outcomes in women who self-selected for individual PFMT using validated quality of life (QoL) questionnaires, the Pelvic Floor Distress Inventory-20 (PFDI-20), the Pelvic Floor Impact Questionnaire-7 (PFIQ-7), the Pelvic Organ Prolapse/Urinary Incontinence Sexual Questionnaire-12 (PISQ-12), as well as the Modified Oxford Scale (MOS) for strength. Women's satisfaction with the program was also assessed. This was a single-center prospective cohort study conducted between December 2013 and September 2014. Changes from baseline to postintervention QoL and MOS scores were tested using the Wilcoxon signed-rank test. Two hundred and eighteen women attended the workshop, 54 enrolled in PFMT sessions, and 50 completed follow-up. Significant improvements were seen in the PFDI-20 (mean change -41.8, p < 0.001) and PFIQ-7 (mean change -23.0, p < 0.001) questionnaires. Results for the PISQ-12 could not be tabulated, as there were too many missing responses. The MOS score was significantly improved from baseline (4; range {0-5} compared with 3; range {0-4}; p < 0.001). Forty-nine of 50 women's expectations for the program were met [9 of 10; standard deviation (SD) 1.4]. Results suggest that a two-tiered, self-selection approach to administering PFMT in the postpartum period contributes to significant improvements in pelvic floor function, QoL, MOS strength, and to high satisfaction rates.
Pilkington, S A; Nugent, K P; Brenner, J; Harris, S; Clarke, A; Lamparelli, M; Thomas, C; Tarver, D
2012-10-01
Accurate and reliable imaging of pelvic floor dynamics is important for tailoring treatment in pelvic floor disorders; however, two imaging modalities are available. Barium proctography (BaP) is widely used, but involves a significant radiation dose. Magnetic resonance (MR) proctography allows visualization of all pelvic midline structures but patients are supine. This project investigates whether there are measurable differences between BaP and MR proctography. Patient preference for the tests was also investigated. Consecutive patients referred for BaP were invited to participate (National Research Ethics Service approved). Participants underwent BaP in Poole and MR proctography in Dorchester. Proctograms were reported by a consultant radiologist with pelvic floor subspecialization. A total of 71 patients were recruited. Both tests were carried out on 42 patients. Complete rectal emptying was observed in 29% (12/42) on BaP and in 2% (1/42) on MR proctography. Anismus was reported in 29% (12/42) on BaP and 43% (18/42) on MR proctography. MR proctography missed 31% (11/35) of rectal intussusception detected on BaP. In 10 of these cases no rectal evacuation was achieved during MR proctography. The measure of agreement between grade of rectal intussusception was fair (κ=0.260) although MR proctography tended to underestimate the grade. Rectoceles were extremely common but clinically relevant differences in size were evident. Patients reported that they found MR proctography less embarrassing but harder to empty their bowel. The results demonstrate that MR proctography under-reports pelvic floor abnormalities especially where there has been poor rectal evacuation. © 2012 The Authors. Colorectal Disease © 2012 The Association of Coloproctology of Great Britain and Ireland.
LOFT. Reactor support apparatus inside containment building (TAN650). Camera is ...
LOFT. Reactor support apparatus inside containment building (TAN-650). Camera is on crane rail level and facing northerly. View shows top two banks of round conduit openings on wall for electrical and other connections to control room. Ladders and platforms provide access to reactor instrumentation. Note hatch in floor and drain at edge of floor near wall. Date: 1974. INEEL negative no. 74-219 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
LOFT. Containment and service building (TAN650). Section through north/south axis. ...
LOFT. Containment and service building (TAN-650). Section through north/south axis. Shows basement and four additional levels of pre-amp tower, shielded roadway, chambers below reactor floor, railroad door, sumps, shielding. Section C shows basement sumps and chambers below reactor floor. Kaiser engineers 6413-11-STEP/LOFT-650-A-5. Date: October 1964. INEEL index code no. 036-650-00-486-122217 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID
2004-02-10
KENNEDY SPACE CENTER, FLA. - A worker on the floor watches as the Multi-Purpose Logistics Module Raffaello moves toward another work stand in the Space Station Processing Facility. Raffaello is the second MPLM built by the Italian Space Agency, serving as a reusable logistics carrier and primary delivery system to resupply and return station cargo requiring a pressurized environment. It has been moved across the floor to allow the third MPLM, Donatello, to be brought in for routine testing. Donatello has been stored in the Operations and Checkout Building. This is the first time all three MPLMs are in the SSPF; the other one is the Leonardo. Raffaello is scheduled to fly on Space Shuttle Atlantis on mission STS-114.
Human Occupancy as a Source of Indoor Airborne Bacteria
Hospodsky, Denina; Qian, Jing; Nazaroff, William W.; Yamamoto, Naomichi; Bibby, Kyle; Rismani-Yazdi, Hamid; Peccia, Jordan
2012-01-01
Exposure to specific airborne bacteria indoors is linked to infectious and noninfectious adverse health outcomes. However, the sources and origins of bacteria suspended in indoor air are not well understood. This study presents evidence for elevated concentrations of indoor airborne bacteria due to human occupancy, and investigates the sources of these bacteria. Samples were collected in a university classroom while occupied and when vacant. The total particle mass concentration, bacterial genome concentration, and bacterial phylogenetic populations were characterized in indoor, outdoor, and ventilation duct supply air, as well as in the dust of ventilation system filters and in floor dust. Occupancy increased the total aerosol mass and bacterial genome concentration in indoor air PM10 and PM2.5 size fractions, with an increase of nearly two orders of magnitude in airborne bacterial genome concentration in PM10. On a per mass basis, floor dust was enriched in bacterial genomes compared to airborne particles. Quantitative comparisons between bacterial populations in indoor air and potential sources suggest that resuspended floor dust is an important contributor to bacterial aerosol populations during occupancy. Experiments that controlled for resuspension from the floor implies that direct human shedding may also significantly impact the concentration of indoor airborne particles. The high content of bacteria specific to the skin, nostrils, and hair of humans found in indoor air and in floor dust indicates that floors are an important reservoir of human-associated bacteria, and that the direct particle shedding of desquamated skin cells and their subsequent resuspension strongly influenced the airborne bacteria population structure in this human-occupied environment. Inhalation exposure to microbes shed by other current or previous human occupants may occur in communal indoor environments. PMID:22529946
Luginbuehl, Helena; Lehmann, Corinne; Baeyens, Jean-Pierre; Kuhn, Annette; Radlinger, Lorenz
2015-11-17
Pelvic floor muscle training is effective and recommended as first-line therapy for female patients with stress urinary incontinence. However, standard pelvic floor physiotherapy concentrates on voluntary contractions even though the situations provoking stress urinary incontinence (for example, sneezing, coughing, running) require involuntary fast reflexive pelvic floor muscle contractions. Training procedures for involuntary reflexive muscle contractions are widely implemented in rehabilitation and sports but not yet in pelvic floor rehabilitation. Therefore, the research group developed a training protocol including standard physiotherapy and in addition focused on involuntary reflexive pelvic floor muscle contractions. The aim of the planned study is to compare this newly developed physiotherapy program (experimental group) and the standard physiotherapy program (control group) regarding their effect on stress urinary incontinence. The working hypothesis is that the experimental group focusing on involuntary reflexive muscle contractions will have a higher improvement of continence measured by the International Consultation on Incontinence Modular Questionnaire Urinary Incontinence (short form), and - regarding secondary and tertiary outcomes - higher pelvic floor muscle activity during stress urinary incontinence provoking activities, better pad-test results, higher quality of life scores (International Consultation on Incontinence Modular Questionnaire) and higher intravaginal muscle strength (digitally tested) from before to after the intervention phase. This study is designed as a prospective, triple-blinded (participant, investigator, outcome assessor), randomized controlled trial with two physiotherapy intervention groups with a 6-month follow-up including 48 stress urinary incontinent women per group. For both groups the intervention will last 16 weeks and will include 9 personal physiotherapy consultations and 78 short home training sessions (weeks 1-5 3x/week, 3x/day; weeks 6-16 3x/week, 1x/day). Thereafter both groups will continue with home training sessions (3x/week, 1x/day) until the 6-month follow-up. To compare the primary outcome, International Consultation on Incontinence Modular Questionnaire (short form) between and within the two groups at ten time points (before intervention, physiotherapy sessions 2-9, after intervention) ANOVA models for longitudinal data will be applied. This study closes a gap, as involuntary reflexive pelvic floor muscle training has not yet been included in stress urinary incontinence physiotherapy, and if shown successful could be implemented in clinical practice immediately. NCT02318251 ; 4 December 2014 First patient randomized: 11 March 2015.
78 FR 69653 - Privacy Act of 1974; System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-20
... Office, 4800 Mark Center Drive, East Tower, 2nd Floor, Suite 02G09, Alexandria, VA 22350-3100... records in the system: Name, nationality, address, email address, home and/or work telephone numbers, cell...
Code of Federal Regulations, 2010 CFR
2010-10-01
... cargo, and its interior walls and floors are free from protrusions. (2) Structurally serviceable means... equipment, mounting and securing chassis or vehicle, or insertion into ships' cells. (3) In addition...
NASA Technical Reports Server (NTRS)
Carden, H. D.
1984-01-01
Three six-place, low wing, twin-engine general aviation airplane test specimens were crash tested at the langley Impact Dynamics research Facility under controlled free-flight conditions. One structurally unmodified airplane was the baseline airplane specimen for the test series. The other airplanes were structurally modified to incorporate load-limiting (energy-absorbing) subfloor concepts into the structure for full scale crash test evaluation and comparison to the unmodified airplane test results. Typically, the lowest floor accelerations and anthropomorphic dummy occupant responses, and the least seat crushing of standard and load-limiting seats, occurred in the modified load-limiting subfloor airplanes wherein the greatest structural crushing of the subfloor took place. The better performing of the two load-limiting subfloor concepts reduced the peak airplane floor accelerations at the pilot and four seat/occupant locations to -25 to -30 g's as compared to approximately -50 to -55 g's acceleration magnitude for the unmodified airplane structure.
Impact of vaginal parity and aging on the architectural design of pelvic floor muscles.
Alperin, Marianna; Cook, Mark; Tuttle, Lori J; Esparza, Mary C; Lieber, Richard L
2016-09-01
Vaginal delivery and aging are key risk factors for pelvic floor muscle dysfunction, which is a critical component of pelvic floor disorders. However, alterations in the pelvic floor muscle intrinsic structure that lead to muscle dysfunction because of childbirth and aging remain elusive. The purpose of this study was to determine the impact of vaginal deliveries and aging on human cadaveric pelvic floor muscle architecture, which is the strongest predictor of active muscle function. Coccygeus, iliococcygeus, and pubovisceralis were obtained from younger donors who were ≤51 years old, vaginally nulliparous (n = 5) and vaginally parous (n = 6) and older donors who were >51 years old, vaginally nulliparous (n = 6) and vaginally parous (n = 6), all of whom had no history of pelvic floor disorders. Architectural parameters, which are predictive of muscle's excursion and force-generating capacity, were determined with the use of validated methods. Intramuscular collagen content was quantified by hydroxyproline assay. Main effects of parity and aging and the interactions were determined with the use of 2-way analysis of variance, with Tukey's post-hoc testing and a significance level of .05. The mean age of younger and older donors differed by approximately 40 years (P = .001) but was similar between nulliparous and parous donors within each age group (P > .9). The median parity was 2 (range, 1-3) in younger and older vaginally parous groups (P = .7). The main impact of parity was increased fiber length in the more proximal coccygeus (P = .03) and iliococcygeus (P = .04). Aging changes manifested as decreased physiologic cross-sectional area across all pelvic floor muscles (P < .05), which substantially exceeded the age-related decline in muscle mass. The physiologic cross-sectional area was lower in younger vaginally parous, compared with younger vaginally nulliparous, pelvic floor muscles; however, the differences did not reach statistical significance. Pelvic floor muscle collagen content was not altered by parity but increased dramatically with aging (P < .05). Increased fiber length in more proximal pelvic floor muscles likely represents an adaptive response to the chronically increased load placed on these muscles by the displaced apical structures, presumably as a consequence of vaginal delivery. In younger specimens, a consistent trend towards decrease in force-generating capacity of all pelvic floor muscles in the parous group suggests a potential mechanism for clinically identified pelvic floor muscle weakness in vaginally parous women. The substantial decrease in predicted muscle force production and fibrosis with aging represent likely mechanisms for the pelvic floor muscle dysfunction in older women. Copyright © 2016 Elsevier Inc. All rights reserved.
Ardali, Gunay; Brody, Lori T; States, Rebecca A; Godwin, Ellen M
2017-10-20
The ability to get up from the floor after a fall is a basic skill required for functional independence. Consequently, the inability to safely get down and up from the floor or to perform a floor transfer (FT) may indicate decreased mobility and/or increased frailty. A reliable and valid test of FT ability is a critical part of the clinical decision-making process. The FT test is a simple, performance-based test that can be administered quickly and easily to determine a patient's ability to safely and successfully get down and up from the floor using any movement strategy and without time restriction. The primary purpose of this cross-sectional study was to determine the intrarater reliability and validity of the FT test as a practical alternative to several widely used yet time-consuming measures of physical disability, frailty, and functional mobility. A total of 61 community-dwelling older adults (65-96 years of age) participated in the study divided into 2 separate subsamples: 15 of them in the intrarater reliability part, while the other 46 in the concurrent validity one. In both subsamples, the participants were stratified on the basis of the self-reported levels of FT ability as independent, assisted, and dependent. Intrarater reliability was assessed in 2 separate occasions and scores were analyzed by intraclass correlation coefficient and κ statistics. Concurrent validity of the FT test was assessed against the self-reported FT ability questionnaire, Physical Functioning Scale, Phenotype of Physical Frailty, and the Short Physical Performance Battery. Known-groups validity was tested by determining whether the FT test distinguished between (1) community-dwelling older adults with physical disabilities versus those who without physical disabilities; and (2) community-dwelling older adults who were functionally dependent versus those who were independent. Participants were also categorized on the basis of FT test outcome as independent, assisted, or dependent. The Spearman correlation coefficients were calculated to examine the strength of the relationships between the FT test and physical status measures. The Kruskal-Wallis test was used to determine whether the FT test significantly discriminated between groups as categorized by the Physical Functioning Scale and Short Physical Performance Battery, and to examine the significance level of the sociodemographic data across the 3 FT test outcome groups. The intrarater reliabilities of the measures were good (0.73-1.00). There were statistically positive and strong correlations between the FT test and all physical status measures (ρ ranged from 0.86 to 0.93, P < .001). Older adults who passed the FT test were collectively categorized as those without physical disabilities and functionally independent, whereas older adults who failed the FT test were categorized as those with physical disabilities and functionally dependent (P < .001). The FT test is a reliable and valid measure for screening for physical disability, frailty, and functional mobility. It can determine which older adults have physical disabilities and/or functional dependence and hence may be useful in assessing readiness for independent living. Inclusion of the FT test at initial evaluation may reveal the presence of these conditions and address the safety of older adults in the community.
40 CFR Table 9 to Subpart IIIii of... - Required Records for Work Practice Standards
Code of Federal Regulations, 2012 CFR
2012-07-01
... Mercury Cell Chlor-Alkali Plants Pt. 63, Subpt. IIIII, Table 9 Table 9 to Subpart IIIII of Part 63... other deficiency in a cell room floor, pillar, or beam that could cause liquid mercury to become trapped... hydrogen leak identified during an inspection required by Table 2 to this subpart or at any other time a...
40 CFR Table 9 to Subpart IIIii of... - Required Records for Work Practice Standards
Code of Federal Regulations, 2011 CFR
2011-07-01
... Mercury Cell Chlor-Alkali Plants Pt. 63, Subpt. IIIII, Table 9 Table 9 to Subpart IIIII of Part 63... other deficiency in a cell room floor, pillar, or beam that could cause liquid mercury to become trapped... hydrogen leak identified during an inspection required by Table 2 to this subpart or at any other time a...
dos Anjos, Daniela Brianne Martins; Rodrigues, Roberta Cunha Matheus; Padilha, Kátia Melissa; Pedrosa, Rafaela Batista dos Santos; Gallani, Maria Cecília Bueno Jayme
2016-01-01
ABSTRACT Objective: evaluate the practicality, acceptability and the floor and ceiling effects, estimate the reliability and verify the convergent construct's validity with the instrument called the Heart Valve Disease Impact on daily life (IDCV) of the valve disease in patients with mitral and or aortic heart valve disease. Method: data was obtained from 86 heart valve disease patients through 3 phases: a face to face interview for a socio-demographic and clinic characterization and then other two done through phone calls of the interviewed patients for application of the instrument (test and repeat test). Results: as for the practicality and acceptability, the instrument was applied with an average time of 9,9 minutes and with 110% of responses, respectively. Ceiling and floor effects observed for all domains, especially floor effect. Reliability was tested using the test - repeating pattern to give evidence of temporal stability of the measurement. Significant negative correlations with moderate to strong magnitude were found between the score of the generic question about the impact of the disease and the scores of IDCV, which points to the validity of the instrument convergent construct. Conclusion: the instrument to measure the impact of valve heart disease on the patient's daily life showed evidence of reliability and validity when applied to patients with heart valve disease. PMID:27992024
Damphousse, M; Jousse, M; Verollet, D; Guinet, A; Le Breton, F; Lacroix, P; Sheik Ismael, S; Amarenco, G
2012-04-01
Proctalgia fugax (PF) is a very common condition especially in women. Causes and pathophysiological mechanisms of PF are unknown. Recently, a pudendal neuropathy was clinically suspected in women with PF. The goal of our study was to demonstrate, or not, such abnormalities by means electrophysiological testing. Fifty-five patients with PF (45 female and 10 male, mean age 50.2 years) were evaluated. EMG testing with motor unit potential analysis of pelvic floor muscles (bulbocavernosus muscle and striated external anal sphincter), study of bulbocavernosus reflex and pudendal nerve terminal motor latencies (PNTML) were performed. EMG testing was altered in two males out of 10 (20%) and 29/45 females (64%). In women, denervation was found bilateral in 25/29 (86%). Sacral latency was delayed in eight out of 29 (bilateral in five cases, unilateral in three cases) and PNTML altered in 17 cases (13 bilateral alteration, four unilateral). A significant difference (P<0.002 Chi(2) test) was demonstrated between male and female concerning pelvic floor muscles denervation. Pelvic floor muscles denervation was a common feature in women suffering from PF, due to a stretch bilateral pudendal neuropathy. Distal lesions of the pudendal nerves, principally due to a stretch perineal neuropathy, can be imagined as a factor or co-factor of PF. Copyright © 2012 Elsevier Masson SAS. All rights reserved.
Oh, Je Hyeok; Kim, Chan Woong; Kim, Sung Eun; Lee, Sang Jin; Lee, Dong Hoon
2014-07-01
When rescuers perform cardiopulmonary resuscitation (CPR) from a standing position, the height at which chest compressions are carried out is raised. To determine whether chest compressions delivered on a bed adjusted to rescuer's knee height are as effective as those delivered on the floor. A total of 20 fourth-year medical students participated in the study. The students performed chest compressions for 2 min each on a manikin lying on the floor (test 1) and on a manikin lying on a bed (test 2). The average compression rate (ACR) and the average compression depth (ACD) were compared between the two tests. The ACR was not significantly different between tests 1 and 2 (120.1 to 132.9 vs 115.7 to 131.2 numbers/min, 95% CI, p=0.324). The ACD was also not significantly different between tests 1 and 2 (51.2 to 56.6 vs 49.4 to 55.7 mm, 95% CI, p=0.058). The results suggest that there may be no significant differences in compression rate and depth between CPR performed on manikins placed on the floor and those placed at a rescuer's knee height. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
MTR MAIN FLOOR. NEUTRON TUNNEL (SPANNED BY STILELIKE STEPS) PROJECTS ...
MTR MAIN FLOOR. NEUTRON TUNNEL (SPANNED BY STILE-LIKE STEPS) PROJECTS FROM THE SOUTHEAST CORNER OF THE MTR TOWARD SOUTHEAST CORNER OF BUILDING, WHERE SHIELDING BLOCKS BEGIN TO SURROUND THE TUNNEL AS IT NEARS DETECTING INSTRUMENTS NEAR THE BUILDING WALL. GEAR RELATED TO CRYSTAL NEUTRON SPECTROMETER IS IN FOREGROUND SURROUNDED BY SHIELDING. DATA CONSOLES ARE AT MID-LEVEL OF EAST FACE. OTHER WORK PROCEEDS ON TOP OF AND ELSEWHERE AROUND REACTOR. NOTE TOOLS HANGING AGAINST SOUTHEAST CORNER, USED TO CHANGE FUEL ELEMENTS AND OTHER REACTOR ITEMS DURING REFUELING CYCLES. INL NEGATIVE NO. 10439. Unknown Photographer, 4/20/1954 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
NASA Technical Reports Server (NTRS)
Mayes, W. H.; Stephens, D. G.; Holmes, H. K.; Lewis, R. B.; Holliday, B. G.; Ward, D. W.; Deloach, R.; Cawthorn, J. M.; Finley, T. D.; Lynch, J. W.
1978-01-01
Outdoor and indoor noise levels resulting from aircraft flyovers and certain nonaircraft events were recorded, as were the associated vibration levels in the walls, windows, and floors at building test sites. In addition, limited subjective tests were conducted to examine the human detection and annoyance thresholds for building vibration and rattle caused by aircraft noise. Representative peak levels of aircraft noise-induced building vibrations are reported and comparisons are made with structural damage criteria and with vibration levels induced by common domestic events. In addition, results of a pilot study are reported which indicate the human detection threshold for noise-induced floor vibrations.
Gupta, Mridula; Bisesi, Michael; Lee, Jiyoung
2017-07-01
The survivability of Staphylococcus aureus and spores of Aspergillus niger was compared on 5 common floor materials. Floor materials were inoculated with a known concentration of S aureus and spores of A niger on day 0. Their survivability was measured on days, 2, 7, 14, and 28 by bulk rinsate method and enumerated using culture-based method. The difference in change of S aureus levels was statistically significant for all tested days (P < .001) for all floor materials. Vinyl composition tile (VCT) and porcelain tile (PT) had statistically similar survivability and differed statistically from carpets. On both VCT and PT, positive growth for S aureus occurred by day 2 (1-1.7 log 10 ), declined slightly (0.1 to -0.2 log 10 ) by day 7, and remained positive until day 28. However, S aureus was undetected by day 7 on both carpets. A niger spores were undetected on residential broadloom carpet and rubber-backed commercial carpet after day 2 but survived on VCT, PT, and wood until day 28. Floor materials with hard and smooth surfaces, such as VCT and PT, can allow survival of S aureus and A niger for up to 4 weeks. It may imply that floor materials can play a major role in preserving microbial contaminants in the built environment. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
De Palo, P; Tateo, A; Zezza, F; Corrente, M; Centoducati, P
2006-12-01
An evaluation of behavioral and hygienic conditions was carried out with 4 materials used as free-stall flooring for dairy cows: polyethylene vinyl acetate (EVA) and polypropylene vinyl acetate (PVA) mats, wood shavings, and solid manure. The free-stall type selected by cows was evaluated in response to changes in environmental temperature and humidity. Two tests were used: 1) a preference test, in which 8 cows were housed in a pen with 32 free stalls and 4 types of flooring; and 2) an aversion test, in which 32 cows were placed in 4 pens, each with 8 free stalls. The free stalls in each pen had a single type of bedding material. These tests showed that the comfort of dairy cows was predominantly influenced by environmental conditions. The preference test for lying showed that cows preferred free-stall floors with EVA mats over those with PVA mats, wood shavings, and solid manure (332.4 +/- 24.0 vs. 130.8 +/- 6.2, 160.9 +/- 23.7, and 102.6 +/- 23.2 min/d, respectively), but under conditions of heat stress, with a temperature-humidity index > 80, they chose wood shavings and solid manure lying areas. These results were confirmed by the aversion test. In all experimental and environmental conditions, the PVA mats were the least suitable. The mats contaminated with organic manure and the free stalls bedded with wood shavings and organic solids did not differ in either the coliform load on the lying surfaces (EVA mats: 290 +/- 25; PVA mats: 306 +/- 33; wood shavings: 290 +/- 39; and solid manure: 305 +/- 23 log(10) cfu/mL) or the total bacterial count in the raw milk (EVA mats: 232 +/- 22; PVA mats: 233 + 24; wood shavings: 221 +/- 24; and solid manure: 220 +/- 25 log(10) cfu/mL). These results demonstrate that the comfort of dairy cows housed in barns with free stalls as resting areas does not depend only on the material used, but also on the value of the material in microenvironmental conditions.
Effect of rubber flooring on dairy cattle stepping behavior and muscle activity.
Rajapaksha, Eranda; Winkler, Christoph; Tucker, Cassandra B
2015-04-01
Use of compressible flooring, such as rubber, has increased on dairy farms. Rubber improves locomotion and is well used by cattle in preference experiments that combine walking and standing. Previous work has found that rubber is particularly beneficial for lame animals, perhaps because a softer material is particularly useful when a single hoof is compromised. The goal of this work was to evaluate the effect of flooring while standing, because cattle in freestall housing spend 40 to 50% of their time engaged in this behavior. In a 2 × 2 design, cows (n = 16) were evaluated on 4 standing surfaces that varied in terms of both floor type (concrete or rubber) and presentation [same floor under all 4 legs (all 4 legs on either concrete or rubber) or a rough surface under only one hind leg and the other 3 legs on concrete or rubber] in a crossover design. Surface electromyograms were used to evaluate muscle fatigue, total activity, and movement of muscle activity between legs during 1 h of standing. Muscle fatigue was evaluated in 2 contexts: (1) static contractions when cows continuously transferred weight to each hind leg, before and after 1 h of standing, and (2) dynamic contractions associated with steps during 1 h on treatment surfaces. In addition, stepping rate, time between each consecutive step, and the latency to lie down after testing were measured. No interaction between floor type and presentation was found. Presentation had a significant effect; when one hind leg was on a rough surface, cattle took 1.7 times more steps with this leg and the non-rough hind leg had 1.2 times more muscle activity, compared with when all 4 legs were on the same surface. These changes are consistent with movement away from concrete with protrusions. When standing on rubber, muscle-activity movements among legs remained stable (0.6-0.7 movements per min) over 1 h but increased on concrete (0.6-0.9 movements per min), indicating that, like humans, cattle may sway to counteract effects of standing. However, additional work, including measurements of blood flow in the leg, is needed to fully understand the biological implications of these changes. Overall, the rubber flooring tested had little effect on standing behavior. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Reilly, E T C; Freeman, R M; Waterfield, M R; Waterfield, A E; Steggles, P; Pedlar, F
2014-12-01
To test whether supervised pelvic floor exercises antenatally will reduce the incidence of postpartum stress incontinence in at-risk primigravidae with bladder neck mobility, ultrasonically proven. Single blind, randomised controlled trial. Antenatal clinic in a UK NHS Trust Hospital. Two hundred and sixty-eight primigravidae attending an antenatal clinic at approximately 20 weeks of gestation with bladder neck mobility, on standardised valsalva, of 5 mm or more linear movement. The median age was 28, ranging from 16 to 47 years. Patients randomised to supervised pelvic floor exercises (n = 139) attended a physiotherapist at monthly intervals from 20 weeks until delivery. The exercises comprised three repetitions of eight contractions each held for six seconds, with two minutes rest between repetitions. These were repeated twice daily. At 34 weeks of gestation the number of contractions per repetition was increased to 12. Both the untreated control group and the study group received verbal advice on pelvic floor exercises from their midwives antenatally. Subjective reporting of stress incontinence at three months postpartum. Pelvic floor strength, using perineometry, and bladder neck mobility measured by perineal ultrasound. Of the 268 women enrolled, information on the main outcome variable was available for 110 in the control group and 120 in the study group. Fewer women in the supervised pelvic floor exercise group reported postpartum stress incontinence, 19.2% compared with 32.7% in the control group (RR 0.59 [0.37-0.92]). There was no change in bladder neck mobility and no difference in pelvic floor strength between groups after exercise, although all those developing postpartum stress incontinence had significantly poorer perineometry scores than those who were continent. The findings suggest that antenatal supervised pelvic floor exercises are effective in reducing the risk of postpartum stress incontinence in primigravidae with bladder neck mobility. © RCOG 2002 BJOG: an International Journal of Obstetrics and Gynaecology.
NASA Astrophysics Data System (ADS)
Kempf, M. J.; Chen, F.; Quigley, M. S.; Pillai, S.; Kern, R.; Venkateswaran, K.
2001-12-01
Hydrogen peroxide vapor is currently the sterilant-of-choice for flight hardware because it is a low-heat sterilization process suitable for use with various spacecraft components. Hydrogen peroxide is a strong oxidizing agent that produces hydroxyl free radicals ( .OH) which attack essential cell components, including lipids, proteins, and DNA. Planetary protection research efforts at the Jet Propulsion Laboratory (JPL) are focused on developing cleaning and sterilization technologies for spacecraft preparation prior to launch. These efforts include research to assess the microbial diversity of spacecraft assembly areas and any extreme characteristics these microbes might possess. Previous studies have shown that some heat-tolerant Bacillus species isolated from the JPL Spacecraft Assembly Facility (SAF) are resistant to recommended hydrogen peroxide vapor sterilization exposures. A Bacillus species, which was related to a hydrogen peroxide resistant strain, was repeatedly isolated from various locations in the JPL-SAF. This species was found in both unclassified (entrance floors, ante-room, and air-lock) and classified (class 100K) (floors, cabinet tops, and air) areas. The phylogenetic affiliation of these strains was carried out using biochemical tests and 16S rDNA sequencing. The 16S rDNA analysis showed >99% sequence similarity to Bacillus pumilus. In order to understand the epidemiology of these strains, a more highly evolved gene (topoisomerase II β -subunit, gyrB) was also sequenced. Among 4 clades, one cluster, comprised of 3 strains isolated from the air-lock area, tightly aligned with the B. pumilus ATCC 7061 type strain (97%). The gyrB sequence similarity of this clade was only 91% with the 3 other clades. The genetic relatedness of these strains, as per pulse field gel electrophoresis patterns, will be presented. The vegetative cells and spores of a number of isolates were tested for their hydrogen peroxide resistance. Cells and spores were separately treated with 5% liquid hydrogen peroxide. After 60 minutes of exposure, the samples were diluted in tryptic soy broth and incubated at 32oC. Vegetative cells of one of the isolates, FO-036b, were the only cells to survive the exposure to hydrogen peroxide. In contrast, spores of several of the isolates survived exposure to hydrogen peroxide. Spores of these isolates do not appear to have any obvious morphological changes. We are in the process of analyzing these hydrogen peroxide resistant spores and comparing them to spores of microbes that are not as hydrogen peroxide resistant. The impact and implications of the identification and recurrence of these hydrogen peroxide microbes, and their spores, will be discussed.
NASA Astrophysics Data System (ADS)
Fu, Yubin; Liu, Jia; Su, Jia; Zhao, Zhongkai; Liu, Yang; Xu, Qian
2012-03-01
Microbial fuel cell (MFC) on the ocean floor is a kind of novel energy- harvesting device that can be developed to drive small instruments to work continuously. The shape of electrode has a great effect on the performance of the MFC. In this paper, several shapes of electrode and cell structure were designed, and their performance in MFC were compared in pairs: Mesh (cell-1) vs. flat plate (cell-2), branch (cell-3) vs. cylinder (cell-4), and forest (cell-5) vs. disk (cell-6) FC. Our results showed that the maximum power densities were 16.50, 14.20, 19.30, 15.00, 14.64, and 9.95 mWm-2 for cell-1, 2, 3, 4, 5 and 6 respectively. And the corresponding diffusion-limited currents were 7.16, 2.80, 18.86, 10.50, 18.00, and 6.900 mA. The mesh and branch anodes showed higher power densities and much higher diffusion-limited currents than the flat plate and the cylinder anodes respectively due to the low diffusion hindrance with the former anodes. The forest cathode improved by 47% of the power density and by 161% of diffusion-limited current than the disk cathode due to the former's extended solid/liquid/gas three-phase boundary. These results indicated that the shape of electrode is a major parameter that determining the diffusion-limited current of an MFC, and the differences in the electrode shape lead to the differences in cell performance. These results would be useful for MFC structure design in practical applications.
Submillimeter bolt location in car bodywork for production line quality inspection
NASA Astrophysics Data System (ADS)
Altamirano-Robles, Leopoldo; Arias-Estrada, Miguel; Alviso-Quibrera, Samuel; Lopez-Lopez, Aurelio
2000-03-01
In the automotive industry, a vehicle begins with the construction of the vehicle floor. Later on, several robots weld a series of bolts to this floor which are used to fix other parts. Due to several problems, like welding tools wearing, robot miscalibration or momentary low power supply, among others, some bolts are incorrectly positioned or are not present at all, bringing problems and delays in the next work cells. Therefore, it is of importance to verify the quality of welded parts before the following assembly steps. A computer vision system is proposed in order to locate autonomously the presence and quality of the bolts. The system should carry on the inspection in real time at the car assembly line under the following conditions: without touching the bodywork, with a precision in the submillimeter range and in few seconds. In this paper we present a basic computer vision system for bolt location in the submillimeter range. We analyze three arrangements of the system components (camera and illumination sources) that produce different results in the localization. Results are presented and compared for the three approaches obtained under laboratory conditions. The algorithms were tested in the assembling line. Variations up to one millimeter in the welded position of the bolts were observed.
Concorde noise-induced building vibrations: John F. Kennedy International Airport
NASA Technical Reports Server (NTRS)
Mayes, W. H.; Stephens, D. G.; Deloach, R.; Cawthorn, J. M.; Holmes, H. K.; Lewis, R. B.; Holliday, B. G.; Ward, D. W.; Miller, W. T.
1978-01-01
Outdoor and indoor noise levels resulting from aircraft flyovers and certain nonaircraft events were recorded at eight homesites and a school along with the associated vibration levels in the walls, windows, and floors at these test sites. Limited subjective tests were conducted to examine the human detection and annoyance thresholds for building vibration and rattle caused by aircraft noise. Both vibration and rattle were detected subjectively in several houses for some operations of both the Concorde and subsonic aircraft. Seated subjects more readily detected floor vibrations than wall or window vibrations. Aircraft noise generally caused more window vibrations than common nonaircraft events such as walking and closing doors. Nonaircraft events and aircraft flyovers resulted in comparable wall vibration levels, while floor vibrations were generally greater for nonaircraft events than for aircraft flyovers. The relationship between structural vibration and aircraft noise is linear, with vibration levels being accurately predicted from overall sound pressure levels (OASPL) measured near the structure. Relatively high levels of structural vibration measured during Concorde operations are due more to higher OASPL levels than to unique Concorde-source characteristics.
78 FR 34352 - Privacy Act of 1974; System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-07
... Management System Office, 4800 Mark Center Drive, East Tower, 2nd Floor, Suite 02G09, Alexandria, VA 22350... Number (DoD ID Number), home and work addresses, work, fax, home and personal cell phone numbers, US...
Wang, W; Erf, G F; Wideman, R F
2002-11-01
Intravenous endotoxin has been shown to trigger a delayed pulmonary hypertensive response that varies widely in magnitude and duration among individual broilers. It was proposed that this individual variability may reflect immunological differences acquired during previous respiratory challenges that might have subsequently altered the endotoxin-initiated biochemical cascade. In Experiment 1, we tested the hypothesis that, when compared with broilers reared in clean stainless steel cages (Cage group), broilers reared on floor litter (Floor group) should experience a greater respiratory challenge and therefore may consistently exhibit a more enhanced pulmonary hypertensive response to intravenous endotoxin. Birds in the Cage group were grown in stainless steel cages at a low density (72 birds/8 m2 chamber), and fecal and dander materials were removed daily. Birds in the Floor group were reared on wood-shavings litter at a higher density (110 birds/8 m2 chamber). Pulmonary and systemic mean arterial pressures and blood-gas values were evaluated prior to and following the intravenous administration of 1 mg Salmonella typhimurium endotoxin. Broilers in the Floor and Cage groups exhibited pulmonary hypertensive responses to endotoxin that were very similar in terms of time of onset, duration, and magnitude, as well as variability in the response among individuals. Systemic hypotension also developed similarly in both groups following endotoxin injection. Blood-gas values indicated that the partial pressure of CO2 and the HCO3- concentration in arterial blood were higher (P < 0.05) in the Floor group than in the Cage group prior to and subsequent to the endotoxin injection. In Experiment 2, we reevaluated the effect of a dirty vs. a clean environment on blood-gas values using a different strain of broilers, and confirmed the negative impact of floor rearing on blood-gas values. We conclude that broilers reared on the floor inhaled litter dust and noxious fumes, which impaired pulmonary gas exchange and increased the arterial partial pressure of CO2 when compared with broilers reared in clean stainless steel cages. Nevertheless, the pulmonary hypertensive response to endotoxin did not differ between broilers reared on the floor and those in cages.
Development and assessment of floor and ceiling items for the PROMIS physical function item bank
2013-01-01
Introduction Disability and Physical Function (PF) outcome assessment has had limited ability to measure functional status at the floor (very poor functional abilities) or the ceiling (very high functional abilities). We sought to identify, develop and evaluate new floor and ceiling items to enable broader and more precise assessment of PF outcomes for the NIH Patient-Reported-Outcomes Measurement Information System (PROMIS). Methods We conducted two cross-sectional studies using NIH PROMIS item improvement protocols with expert review, participant survey and focus group methods. In Study 1, respondents with low PF abilities evaluated new floor items, and those with high PF abilities evaluated new ceiling items for clarity, importance and relevance. In Study 2, we compared difficulty ratings of new floor items by low functioning respondents and ceiling items by high functioning respondents to reference PROMIS PF-10 items. We used frequencies, percentages, means and standard deviations to analyze the data. Results In Study 1, low (n = 84) and high (n = 90) functioning respondents were mostly White, women, 70 years old, with some college, and disability scores of 0.62 and 0.30. More than 90% of the 31 new floor and 31 new ceiling items were rated as clear, important and relevant, leaving 26 ceiling and 30 floor items for Study 2. Low (n = 246) and high (n = 637) functioning Study 2 respondents were mostly White, women, 70 years old, with some college, and Health Assessment Questionnaire (HAQ) scores of 1.62 and 0.003. Compared to difficulty ratings of reference items, ceiling items were rated to be 10% more to greater than 40% more difficult to do, and floor items were rated to be about 12% to nearly 90% less difficult to do. Conclusions These new floor and ceiling items considerably extend the measurable range of physical function at either extreme. They will help improve instrument performance in populations with broad functional ranges and those concentrated at one or the other extreme ends of functioning. Optimal use of these new items will be assisted by computerized adaptive testing (CAT), reducing questionnaire burden and insuring item administration to appropriate individuals. PMID:24286166
Zeng, Deliang; Xia, Lunguo; Zhang, Wenjie; Huang, Hui; Wei, Bin; Huang, Qingfeng; Wei, Jie; Liu, Changsheng; Jiang, Xinquan
2012-04-01
The objective of this study was to assess the effects of maxillary sinus floor elevation with a tissue-engineered bone constructed with bone marrow stromal cells (bMSCs) and calcium-magnesium phosphate cement (CMPC) material. The calcium (Ca), magnesium (Mg), and phosphorus (P) ions released from calcium phosphate cement (CPC), magnesium phosphate cement (MPC), and CMPC were detected by inductively coupled plasma atomic emission spectroscopy (ICP-AES), and the proliferation and osteogenic differentiation of bMSCs seeded on CPC, MPC, and CMPC or cultured in CPC, MPC, and CMPC extracts were measured by MTT analysis, alkaline phosphatase (ALP) activity assay, alizarin red mineralization assay, and real-time PCR analysis of the osteogenic genes ALP and osteocalcin (OCN). Finally, bMSCs were combined with CPC, MPC, and CMPC and used for maxillary sinus floor elevation in rabbits, while CPC, MPC, or CMPC without cells served as control groups. The new bone formation in each group was detected by histological finding and fluorochrome labeling at weeks 2 and 8 after surgical operation. It was observed that the Ca ion concentrations of the CMPC and CPC scaffolds was significantly higher than that of the MPC scaffold, while the Mg ions concentration of CMPC and MPC was significantly higher than that of CPC. The bMSCs seeded on CMPC and MPC or cultured in their extracts proliferated more quickly than the cells seeded on CPC or cultured in its extract, respectively. The osteogenic differentiation of bMSCs seeded on CMPC and CPC or cultured in the corresponding extracts was significantly enhanced compared to that of bMSCs seeded on MPC or cultured in its extract; however, there was no significant difference between CMPC and CPC. As for maxillary sinus floor elevation in vivo, CMPC could promote more new bone formation and mineralization compared to CPC and MPC, while the addition of bMSCs could further enhance its new bone formation ability significantly. Our data suggest that CMPC possesses moderate biodegradability and excellent osteoconductivity, which may be attributed to its Ca and Mg ion composition, and the tissue-engineered bone constructed of CMPC and bMSCs might be a potential alterative graft for maxillofacial bone regeneration.
NASA Technical Reports Server (NTRS)
Shields, N. L., Jr.; Martin, M. F.; Paulukaitis, K. R.; Haslam, J. W., Jr.; Henderson, D. E.
1986-01-01
The teleoperator and Robotics Evaluation Facility (TOREF) is composed of a 4,000 square foot precision air bearing floor, the Teleoperator Motion Base, the Target Motion and Support Simulator, the mock-ups of the Hubble Space Telescope, Multi-mission Modular Spacecraft, and the Orbital Maneuvering Vehicle (OMV). The TOREF and its general capabilities to support the OMV and other remote system simulations; the facility operating procedures and requirements; and the results of generic OMV investigations are summarized.
PBF Reactor Building (PER620). Camera on main floor faces south ...
PBF Reactor Building (PER-620). Camera on main floor faces south (open) doorway. In foreground is canal gate, lined with stainless steel and painted with protective coatings. Reactor pit is round with protective coatings. Reactor put is round form discernible beyond. Lifting beams and rigging are in place for a load test before reactor vessel arrives. Photographer: John Capek. Date: January 26, 1970. INEEL negative no. 70-347 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
This photocopy of an engineering drawing shows the floor plan ...
This photocopy of an engineering drawing shows the floor plan of the Liner Lab, including room functions. Austin, Field & Fry, Architects Engineers, 22311 West Third Street, Los Angeles 57, California: Edwards Test Station Complex Phase II, Jet Propulsion Laboratory, California Institute of Technology, Edwards Air Force Base, Edwards, California: "Liner Laboratory, Floor Plan and Schedules," drawing no. E33/4-2, 26 June 1962. California Institute of Technology, Jet Propulsion Laboratory, Plant Engineering: engineering drawings of structures at JPL Edwards Facility. Drawings on file at JPL Plant Engineering, Pasadena, California. California Institute of Technology, Jet Propulsion Laboratory, Plant Engineering: engineering drawings of structures at JPL Edwards Facility. Drawings on file at JPL Plant Engineering, Pasadena, California - Jet Propulsion Laboratory Edwards Facility, Liner Laboratory, Edwards Air Force Base, Boron, Kern County, CA
Deterioration of the Floor of Interior Courtyard of Sultan Hassan Mosque in Cairo, Egypt.
NASA Astrophysics Data System (ADS)
Nazel, Tarek
The college- mosque of Sultan Hassan is considered one of the finest examples of Islamic architecture not only in Egypt but also in the East. Its open interior courtyard is paved with three different types of marble slabs. These marble slabs suffer from severe deterioration. Causes of this deterioration were determined accurately through the ocular examination of the courtyard and confirmed by the laboratory tests which were carried out on samples representing the three common types of marble used in the floor namely the white, the red and the black marble. Sun light and heat are the main deterioration factors and the consequent thermal expansion is the main property which led to the detected deterioration phenomena. Types and mechanisms of deterioration affected the floor were described and explained.
New step toward geodetic range observations at the sea floor with the BBOBS system
NASA Astrophysics Data System (ADS)
Shiobara, H.; Shinohara, M.; Isse, T.
2011-12-01
Since 1999, we had developed the broadband ocean bottom seismometer (BBOBS) and its new generation model (BBOBS-NX), and performed several practical observations with them in these ten years to create a category of the ocean floor broadband seismology. Now, the BBOBS data is proved to be acceptable for broadband seismic analyses. In these studies, the period range of the data used is about 10 - 200 s, but in longer period range, i.e. geodetic range, is an unknown region in observations at the sea floor. The acoustic GPS link observation is one of successful methods to know horizontal movement of the sea floor, but it is difficult to obtain continuous data in time. The borehole tilt-meter system is ideal in observational conditions, but it is impossible to expand spatially dense observation network. On the other hand, high mobility of our BBOBS and BBOBS-NX can be a breakthrough for this kind of observation network. So that, based on our BBOBS technology, two kinds of attempts to expand observation range toward the geodetic one have been started since 2009. Our aim in these attempts is to extend observation periods more than one week long for detecting slow slip events, as a first step. Finally, we would like to build the observation network by using them. The first attempt is a precise pressure measurement to detect vertical displacement at the sea floor by attaching an absolute pressure gauge and a parasitic data logger to the original OBS data recorder. The stable frequency oscillator (MCXO) in the data recorder is useful for precise pressure measurement of the gauge with frequency outputs. Although the final resolution of the pressure becomes smaller than 1 Pa, we still have problems due to the drift of the gauge and some scale of sea level change in practical observations. The total precision of the pressure value is also affected by the shift and drift of the frequency standard to measure frequency output signals of the gauge. In our measurements, this effect is estimated less than 60 Pa from the maximum frequency deviation of the MCXO, but it will be negligible by using a small chip scale atomic clock (CSAC), which is available now, as the frequency standard. The second one is a tilt observation just beneath the sea floor by using the BBOBS-NX system, which had been tested 6 times in 2008 - 2010 by free falling deployment with appropriate penetration to the sea floor sediment. The tilt is measured by using two horizontal mass position (acceleration) signals of the broadband sensor. The noise reduction ratio in horizontal components of the BBOBS-NX compared with those of the BBOBS staying on the sea floor is more than 10 in the period range longer than 10 s. It means the possibility of the BBOBS-NX system for the tilt observation in the geodetic range. As we didn't record the mass position signal continuously, a test observation was performed by using the same sensor of the BBOBS-NX at the ERI's Nokogiriyama observatory in 2010. The result is comparable with that of the water tube tilt-meter there in the diurnal Earth tide range. In July 2011, we started a test observation of the tilt measurement at the sea floor SE off Kii peninsula by using the BBOBS-NX as the feasibility study. The deployment was ideally performed by the ROV, and the recovery is planned in January 2012.
A Monocular Vision Sensor-Based Obstacle Detection Algorithm for Autonomous Robots
Lee, Tae-Jae; Yi, Dong-Hoon; Cho, Dong-Il “Dan”
2016-01-01
This paper presents a monocular vision sensor-based obstacle detection algorithm for autonomous robots. Each individual image pixel at the bottom region of interest is labeled as belonging either to an obstacle or the floor. While conventional methods depend on point tracking for geometric cues for obstacle detection, the proposed algorithm uses the inverse perspective mapping (IPM) method. This method is much more advantageous when the camera is not high off the floor, which makes point tracking near the floor difficult. Markov random field-based obstacle segmentation is then performed using the IPM results and a floor appearance model. Next, the shortest distance between the robot and the obstacle is calculated. The algorithm is tested by applying it to 70 datasets, 20 of which include nonobstacle images where considerable changes in floor appearance occur. The obstacle segmentation accuracies and the distance estimation error are quantitatively analyzed. For obstacle datasets, the segmentation precision and the average distance estimation error of the proposed method are 81.4% and 1.6 cm, respectively, whereas those for a conventional method are 57.5% and 9.9 cm, respectively. For nonobstacle datasets, the proposed method gives 0.0% false positive rates, while the conventional method gives 17.6%. PMID:26938540
NASA Astrophysics Data System (ADS)
Sukmaji, I. C.; Wijang, W. R.; Andri, S.; Bambang, K.; Teguh, T.
2017-01-01
Nowadays composite is a superior material used in automotive component due to its outstanding mechanical behavior. The sandwich polypropylene honeycomb core with carbon/glass fiber composite skin (SHCG) as based material in a floor component of electric car application is investigated in the present research. In sandwich structure form, it can absorb noise better compare with the conventional material [1]. Also in present paper, Finite Element Analysis (FEA) of SHCG as based material for floor component of the electric car is analyzed. The composite sandwich is contained with a layer uniform carbon fiber and mixing non-uniform carbon-glass fiber in upper and lower skin. Between skins of SHCG are core polypropylene honeycomb that it have good flexibility to form following dies profile. The variables of volume fraction ratio of carbon/glass fiber in SHCG skin are 20/80%, 30/70%, and 50/50%. The specimen of SHCG is tested using the universal testing machine by three points bending method refers to ASTM C393 and ASTM C365. The cross point between tensile strength to the volume fraction the mixing carbon/glass line and ratio cost line are the searched material with good mechanical performance and reasonable cost. The point is 30/70 volume fraction of carbon/glass fiber. The result of the testing experiment is become input properties of model structure sandwich in FEA simulation. FEA simulation approach is conducted to find critical strength and factor of complex safety geometry against varied distributed passenger loads of a floor component the electric car. The passenger loads variable are 80, 100, 150, 200, 250 and 300 kg.
Chevalier, Francine; Fernandez-Lao, Carolina; Cuesta-Vargas, Antonio Ignacio
2014-11-25
To describe the clinical, functional and quality of life characteristics in women with Stress Urinary Incontinence (SUI). In addition, to analyse the relationship between the variables reported by the patients and those informed by the clinicians, and the relationship between instrumented variables and the manual pelvic floor strength assessment. Two hundred and eighteen women participated in this observational, analytical study. An interview about Urinary Incontinence and the quality of life questionnaires (EuroQoL-5D and SF-12) were developed as outcomes reported by the patients. Manual muscle testing and perineometry as outcomes informed by the clinician were assessed. Descriptive and correlation analysis were carried out. The average age of the subjects was (39.93 ± 12.27 years), (24.49 ± 3.54 BMI). The strength evaluated by manual testing of the right levator ani muscles was 7.79 ± 2.88, the strength of left levator ani muscles was 7.51 ± 2.91 and the strength assessed with the perineometer was 7.64 ± 2.55. A positive correlation was found between manual muscle testing and perineometry of the pelvic floor muscles (p < .001). No correlation was found between outcomes of quality of life reported by the patients and outcomes of functional capacity informed by the physiotherapist. A stratification of the strength of pelvic floor muscles in a normal distribution of a large sample of women with SUI was done, which provided the clinic with a baseline. There is a relationship between the strength of the pelvic muscles assessed manually and that obtained by a perineometer in women with SUI. There was no relationship between these values of strength and quality of life perceived.
The role of tridimensional dynamic ultrasound for pelvic floor evaluation.
de la Portilla, Fernando; Rubio Manzanares Dorado, Mercedes; Pino Díaz, Verónica; Vazquez Monchul, Jorge M; Palacios, Carmen; Díaz Pavón, José M; Sánchez Gil, José M; García Cabrera, Ana María
2015-10-01
Dynamic endoanal ultrasound has emerged in recent years as a test that could replace the now existing tests in the diagnosis of pelvic floor disorders. The aim of this paper is to determine the usefulness of echodefecography in the diagnosis and evaluation of patients with symptoms of anorrectal obstruction, and show the results obtained after its implementation in a pelvic floor unit, as a complementary tool that could replace conventional defecography. In this retrospective study we analyzed 66 patients with a mean age of 55 years (19-83), 61 women (92%). All dynamic ultrasound was performed in 3 dimensions and was correlated with symptoms and physical findings in the consultation. A descriptive and inferential study was performed to find a kappa correlation between physical examination and echodefecography. The reasons for consultation were: Anorrectal obstruction syndrome 36 patients (54.5%), pelvic organ prolapse 27 patients (40.9%), and anorrectal obstruction syndrome along with pelvic organ prolapse 3 patients (4.5%). The correlation of the 2 groups indicated that echodefecography diagnosed more patients with grade III rectocele, enteroceles, and anismus than the combination of scan-ultrasound-manometry-proctoscopy (Kappa 0.26, 0.38 and 0.21, 95% CI: from 0,07 to 1.00, 0.15 to 1.00 and from 0.12 to 1.00, respectively) (P<.001). Conversely, echodefecography diagnosed less perineal descense (Kappa 0.28, 95% CI: 0.12 to 1.00). Dynamic anal ultrasonography may have a role as a complementary test in patients with pelvic floor disorders, achieving diagnoses that would go undetected by inspection, physical examination and manometry. Copyright © 2014 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.
Yun, Seok Hyeon; Park, Sang Jin; Sim, Chang Sun; Sung, Joo Hyun; Kim, Ahra; Lee, Jang Myeong; Lee, Sang Hyun; Lee, Jiho
2017-01-01
Recently, noise coming from the neighborhood via floor wall has become a great social problem. The noise between the floors can be a cause of physical and psychological problems, and the different types of floor impact sound (FIS) may have the different effects on the human's body and mind. The purpose of this study is to assess the responses of subjective feeling, task performance ability, cortisol and HRV for the various types of floor impact. Ten men and 5 women were enrolled in our study, and the English listening test was performed under the twelve different types of FIS, which were made by the combinations of bang machine (B), tapping machine (T), impact ball (I) and sound-proof mattress (M). The 15 subjects were exposed to each FIS for about 3 min, and the subjective annoyance, performance ability (English listening test), cortisol level of urine/saliva and heart rate variability (HRV) were examined. The sound pressure level (SPL) and frequency of FIS were analyzed. Repeated-measures ANOVA, paired t-test, Wilcoxon signed rank test were performed for data analysis. The SPL of tapping machine (T) was reduced with the soundproof mattress (M) by 3.9-7.3 dBA. Impact ball (I) was higher than other FIS in low frequency (31.5-125 Hz) by 10 dBA, and tapping machine (T) was higher than other FIS in high frequency (2-4 k Hz) by 10 dBA. The subjective annoyance is highest in the combination of bang machine and tapping machine (BT), and next in the tapping machine (T). The English listening score was also lowest in the BT, and next in T. The difference of salivary cortisol levels between various types of FIS was significant ( p = 0.003). The change of HRV parameters by the change of FIS types was significant in some parameters, which were total power (TP) ( p = 0.004), low frequency (LF) ( p = 0.002) and high frequency (HF) ( p = 0.011). These results suggest that the human's subjective and objective responses were different according to FIS types and those combinations.
Crash Simulation of a Boeing 737 Fuselage Section Vertical Drop Test
NASA Technical Reports Server (NTRS)
Fasanella, Edwin L.; Jackson, Karen E.; Jones, Yvonne T.; Frings, Gary; Vu, Tong
2004-01-01
A 30-ft/s vertical drop test of a fuselage section of a Boeing 737 aircraft was conducted in October of 1999 at the FAA Technical Center in Atlantic City, NJ. This test was performed to evaluate the structural integrity of a conformable auxiliary fuel tank mounted beneath the floor and to determine its effect on the impact response of the airframe structure and the occupants. The test data were used to compare with a finite element simulation of the fuselage structure and to gain a better understanding of the impact physics through analytical/experimental correlation. To perform this simulation, a full-scale 3-dimensional finite element model of the fuselage section was developed using the explicit, nonlinear transient-dynamic finite element code, MSC.Dytran. The emphasis of the simulation was to predict the structural deformation and floor-level acceleration responses obtained from the drop test of the B737 fuselage section with the auxiliary fuel tank.
NASA Technical Reports Server (NTRS)
Regian, J. Wesley; Shebilske, Wayne; Monk, John M.
1993-01-01
We explored the training potential of Virtual Reality (VR) technology. Thirty-one adults were trained and tested on spatial skills in a VR. They learned a sequence of button and knob responses on a VR console and performed flawlessly on the same console. Half were trained with a rote strategy; the rest used a meaningful strategy. Response times were equivalent for both groups and decreased significantly over five test trials indicating that learning continued on VR tests. The same subjects practiced navigating through a VR building, which had three floors with four rooms on each floor. The dependent measure was the number of rooms traversed on routes that differed from training routes. Many subjects completed tests in the fewest rooms possible. All subjects learned configurational knowledge according to the criterion of taking paths that were significantly shorter than those predicted by a random walk as determined by a Monte Carlo analysis. The results were discussed as a departure point for empirically testing the training potential of VR technology.
Nuclear Organization and Myt1 Interaction in Transcriptional Control of Neural Cell Differentiation
2002-01-01
secreted from the notochord and floor plate [4]. Oligodendrocytes also respond to cell contact- dependent interactions from the notch-signaling pathway...appendix A 1 mature oligodendrocytes sending out multiple processes to begin myelinating axons primarily during the postnatal period of...snRNA transcription [32]. 7 Gene regulation also occurs post-transcriptionally in processes such as RNA splicing. Many splicing factors are
The Langley 14- by 22-Foot Subsonic Tunnel: Description, Flow Characteristics, and Guide for Users
NASA Technical Reports Server (NTRS)
Gentry, Garl L., Jr.; Quinto, P. Frank; Gatlin, Gregory M.; Applin, Zachary T.
1990-01-01
The Langley 14- by 22-foot Subsonic Tunnel is a closed circuit, single-return atmospheric wind tunnel with a test section that can be operated in a variety of configurations (closed, slotted, partially open, and open). The closed test section configuration is 14.5 ft high by 21.75 ft wide and 50 ft long with a maximum speed of about 338 ft/sec. The open test section configuration has a maximum speed of about 270 ft/sec, and is formed by raising the ceiling and walls, to form a floor-only configuration. The tunnel may be configured with a moving-belt ground plane and a floor boundary-layer removal system at the entrance to the test section for ground effect testing. In addition, the tunnel had a two-component laser velocimeter, a frequency modulated (FM) tape system for dynamic data acquisition, flow visualization equipment, and acoustic testing capabilities. Users of the 14- by 22-foot Subsonic Tunnel are provided with information required for planning of experimental investigations including test hardware and model support systems.
Karino, Masaaki; Kanno, Takahiro; Kaneko, Ichiro; Ide, Taichi; Yoshino, Aya; Sekine, Joji
2017-11-01
We usually perform surgery for resectable oral and maxillofacial carcinomas. Following complete cancer resection, reconstruction of soft and hard tissues using various types of local flaps and/or vascularized free flaps is usually performed. The maxilla is composed of various anatomical structures. In particular, reconstruction of the orbit is one of the most important and challenging procedures for prevention of functional and esthetic complications. Here we report 2 cases of orbital floor defect reconstruction following advanced maxillary cancer resection using a pedicled coronoid process and temporal muscle (fascial)combined(PCPTM)flap. Case 1: A 69-year-old Japanese man with squamous cell carcinoma of the left maxilla (cT4aN2bM0, Stage IV A). Case 2: An 86-year-old Japanese woman with recurrence of myoepithelial carcinoma of the left maxilla. In both cases, the orbital floor defect was reconstructed following hemi-maxillectomy using a PCPTM flap. Minor infection and/or partial necrosis were observed postoperatively, and a maxillofacial prosthesis was used in one case. A PCPTM flap was feasible for reconstruction of surgical defects of the orbital floor following maxillectomy for cancer.
Deegan, Emily G; Stothers, Lynn; Kavanagh, Alex; Macnab, Andrew J
2018-01-01
There remains no gold standard for quantification of voluntary pelvic floor muscle (PFM) strength, despite international guidelines that recommend PFM assessment in females with urinary incontinence (UI). Methods currently reported for quantification of skeletal muscle strength across disciplines are systematically reviewed and their relevance for clinical and academic use related to the pelvic floor are described. A systematic review via Medline, PubMed, CINHAL, and the Cochrane database using key terms for pelvic floor anatomy and function were cross referenced with skeletal muscle strength quantification from 1946 to 2016. Full text peer-reviewed articles in English having female subjects with incontinence were identified. Each study was analyzed for use of controls, type of methodology as direct or indirect measures, benefits, and limitations of the technique. A total of 1586 articles were identified of which 50 met the inclusion criteria. Nine methodologies of determining PFM strength were described including: digital palpation, perineometer, dynamometry, EMG, vaginal cones, ultrasonography, magnetic resonance imaging, urine stream interruption test, and the Colpexin pull test. Thirty-two percent lacked a control group. Technical refinements in both direct and indirect instrumentation for PFM strength measurement are allowing for sensitivity. However, the most common methods of quantification remain digital palpation and perineometry; techniques that pose limitations and yield subjective or indirect measures of muscular strength. Dynamometry has potential as an accurate and sensitive tool, but is limited by inability to assess PFM strength during dynamic movements. © 2017 Wiley Periodicals, Inc.
Noise-Optimized Silicon Radiometers
Eppeldauer, George P.
2000-01-01
This paper describes a new, experimentally verified, noise analysis and the design considerations of the dynamic characteristics of silicon radiometers. Transimpedance gain, loop gain, and voltage gain were optimized versus frequency for photodiode current meters measuring ac and dc optical radiation. Silicon radiometers with improved dynamic characteristics were built and tested. The frequency-dependent photocurrent gains were measured. The noise floor was optimized in an ac measurement mode using photodiodes of different shunt resistance and operational amplifiers with low 1/f voltage and current noise. In the dark (without any signal), the noise floor of the optimized silicon radiometers was dominated by the Johnson noise of the source resistance. The Johnson noise was decreased and equalized to the amplified 1/f input noise at a 9 Hz chopping frequency and 30 s integration time constant, resulting in an equivalent root-mean-square (rms) photocurrent noise of 8 × 10−17 A. The lowest noise floor of 5 × 10−17 A, equal to a noise equivalent power (NEP) of 1.4 × 10−16 W at the 730 nm peak responsivity, was obtained at a 100 s integration time constant. The radiometers, optimized for ac measurements, were tested in a dc measurement mode as well. Performances in ac and dc measurement modes were compared. In the ac mode, a ten times shorter (40 s) overall measurement time was needed than in the dc mode (400 s) to obtain the same 10−16 A noise floor. PMID:27551606
Effects of a single inhalative exposure to formaldehyde on the open field behavior of mice.
Malek, Fathi A; Möritz, Klaus-Uwe; Fanghänel, Jochen
2004-02-01
The effects of formaldehyde on the explorative behavior and locomotor activity of mice after a single inhalative exposure were examined in an open field. Adult male mice were exposed to approximately 1.1 ppm, 2.3 ppm, or 5.2 ppm formaldehyde vapour for 2 hours and the open field test was carried out two hours after the end of exposure (trial 1) and repeated 24 hours thereafter (trial 2). The following behavioral parameters were quantitatively examined: numbers of crossed floor squares (inner, peripheral, total), sniffing, grooming, rearing, climbing, and incidence of fecal boli. The results of the first trial revealed that the motion activity was significantly reduced in all exposed groups. In the 1.1 ppm group, the frequency of rearing was reduced and that of floor sniffing increased. The exposure to the two higher formaldehyde concentrations caused a significant decrease in total numbers of floor squares crossed by the subjects, air sniffing, and rearing. The open field test on the next day (trial 2) showed that the frequencies of floor sniffing, grooming, and rearing in all formaldehyde groups were significantly altered. In the 2.5 ppm group, an increased incidence of fecal boli was observed. From the results obtained, we conclude that the exposure of male mice to formaldehyde vapour affects their locomotor and explorative activity in the open field, and that some open field parameters are still altered in the exposed animals even after 24 hours.
Recent Improvements to the Acoustical Testing Laboratory at the NASA Glenn Research Center
NASA Technical Reports Server (NTRS)
Podboy, Devin M.; Mirecki, Julius H.; Walker, Bruce E.; Sutliff, Daniel L.
2014-01-01
The Acoustical Testing Laboratory (ATL) consists of a 27- by 23- by 20-ft (height) convertible hemi/anechoic chamber and separate sound-attenuating test support enclosure. Absorptive fiberglass wedges in the test chamber provide an anechoic environment down to 100 Hz. A spring-isolated floor system affords vibration isolation above 3 Hz. These specifications, along with very low design background levels, enable the acquisition of accurate and repeatable acoustical measurements on test articles that produce very low sound pressures. Removable floor wedges allow the test chamber to operate in either a hemi-anechoic or anechoic configuration, depending on the size of the test article and the specific test being conducted. The test support enclosure functions as a control room during normal operations. Recently improvements were accomplished in support of continued usage of the ATL by NASA programs including an analysis of the ultra-sonic characteristics. A 3-D traverse system inside the chamber was utilized for acquiring acoustic data for these tests. The traverse system drives a linear array of 13, 1/4 in.-microphones spaced 3 in. apart (36 in. span). An updated data acquisition system was also incorporated into the facility.
Recent Improvements to the Acoustical Testing Laboratory at the NASA Glenn Research Center
NASA Technical Reports Server (NTRS)
Podboy, Devin M.; Mirecki, Julius H.; Walker, Bruce E.; Sutliff, Daniel L.
2014-01-01
The Acoustical Testing Laboratory (ATL) consists of a 27 by 23 by 20 ft (height) convertible hemi/anechoic chamber and separate sound-attenuating test support enclosure. Absorptive fiberglass wedges in the test chamber provide an anechoic environment down to 100 Hz. A spring-isolated floor system affords vibration isolation above 3 Hz. These specifications, along with very low design background levels, enable the acquisition of accurate and repeatable acoustical measurements on test articles that produce very low sound pressures. Removable floor wedges allow the test chamber to operate in either a hemi-anechoic or anechoic configuration, depending on the size of the test article and the specific test being conducted. The test support enclosure functions as a control room during normal operations. Recently improvements were accomplished in support of continued usage of the ATL by NASA programs including an analysis of the ultra-sonic characteristics. A 3 dimensional traverse system inside the chamber was utilized for acquiring acoustic data for these tests. The traverse system drives a linear array of 13, 1/4"-microphones spaced 3" apart (36" span). An updated data acquisition system was also incorporated into the facility.
Effect of softer flooring in tie stalls on resting behavior and leg injuries of lactating cows.
Rushen, J; Haley, D; de Passillé, A M
2007-08-01
To test the advantages of softer flooring in tie stalls, we compared the behavior and injuries of dairy cows housed in tie stalls with either soft rubber mats (n = 12) or concrete flooring (n = 12), both lightly covered with straw. Data were collected for 112 d beginning at 14 DIM (+/-4 d). Cows' general activity was observed continuously for 24 h every 28 d. Behavior was also scored by a scan sampling technique every 14 d such that each cow was observed for a period of 3 min every 12 min. We scored the occurrence of leg lesions and other injuries every 7 d throughout the study. Cows on rubber mats had shorter bouts of lying but the frequency of bouts was higher, leading them to tend to spend more time lying compared with cows housed on concrete. Cows on concrete spent more time standing idle, but there was no difference in the time spent eating. There was no effect of stall flooring on the number of minor abrasions to the legs and body. There was a significantly higher incidence of swelling of the carpus joints for cows housed on concrete. Cows housed on soft rubber flooring appeared to be less hesitant to change posture from lying to standing (and vice versa), and as a result changed posture more frequently and spent more time lying than cows on concrete flooring. The decreased incidence of swelling of the carpus joint for cows on soft rubber mats may have important long-term effects in preventing a variety of leg problems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Elhajj, N.R.
1999-03-01
Since 1992, the US Department of Housing and Urban Development has sponsored numerous studies to identify, evaluate, and implement innovative structural materials, such as cold-formed steel (CFS), in the residential market. The use of CFS is still very limited, partly because steel is not being effectively integrated into conventional home construction. One of the major barriers to the use of CFS floor joists is the impact it has on placement of large waste drains and ductwork installed in floor systems. This report provides an overview of tests conducted by the NAHB to integrate these systems with CFS. A brief literaturemore » review of relevant work followed by a detailed overview of the experimental and analytical approach are also provided. The report recommends adoption of the research findings in residential and commercial applications.« less
Gross decontamination experiment report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mason, R.; Kinney, K.; Dettorre, J.
1983-07-01
A Gross Decontamination Experiment was conducted on various levels and surfaces of the TMI - Unit 2 reactor building in March 1982. The polar crane, D-rings, missile shields, refueling canals, refueling bridges, equipment, and elevations 305' and 347'-6'' were flushed with low pressure water. Additionally, floor surfaces on elevation 305' and floor surfaces and major pieces of equipment on elevation 347'-6'' were sprayed with high pressure water. Selective surfaces were decontaminated with a mechanical scrubber and chemicals. Strippable coating was tested and evaluated on equipment and floor surfaces. The effectiveness, efficiency, and safety of several decontamination techniques were established formore » the large, complex decontamination effort. Various decontamination equipment was evaluated and its effectiveness was documented. Decontamination training and procedures were documented and evaluated, as were the support system and organization for the experiment.« less
Psychometric properties of the Mayo Elbow Performance Score.
Celik, Derya
2015-06-01
To translate and culturally adapt the Mayo Elbow Performance Score (MEPS), a widely used instrument for evaluating disability associated with elbow injuries, into Turkish (MEPS-T) and to determine psychometric properties of the translated version. The MEPS was translated into Turkish using published methodological guidelines. The measurement properties of the MEPS-T (construct validity and floor and ceiling effects) were tested in 91 patients with elbow pathology. The reproducibility of the MEPS-T was tested in 59 patients over 7-14 days. The responsiveness of the MEPS-T was tested in a subgroup of 46 patients diagnosed with lateral epicondylitis and who received conservative treatment for 6 weeks. The interclass correlation coefficient (ICC) was used to estimate the test-retest reliability. The construct validity was analyzed with the disabilities of the arm, shoulder and hand (DASH), Visual Analog Scale (VAS) and the Short Form 36 (SF-36). Effect size (ES) was used to assess the responsiveness. The distribution of floor and ceiling effects was determined. The MEPS-T showed very good test-retest reliability (ICC 0.89). The correlation coefficients between the MEPS-T and DASH and VAS were -0.61 and -0.53, respectively (p < 0.001). The highest correlations were between the MEPS-T and the mental component summary (r = 0.47, p = 0.001) and role emotional (r = 0.45, p = 0.001). The MEPS-T ES, 0.50, was moderate (95% CI 0.33-0.62). We observed no ceiling or floor effects. The MEPS-T represents a valid, reliable and moderately responsive instrument for evaluating patients with elbow disease.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-05
...., train separation, redundancy, and single failure). The water level on the containment floor will be... testing requirements are conducted in accordance with the McGuire Inservice Testing Program and TS 3.6.6... Condition for Operation (LCO) 3.10.1, ``Inservice Leak and Hydrostatic Testing Operation,'' and the...
Guattery, Jason M; Dardas, Agnes Z; Kelly, Michael; Chamberlain, Aaron; McAndrew, Christopher; Calfee, Ryan P
2018-04-01
The Patient Reported Outcomes Measurement Information System (PROMIS) was developed to provide valid, reliable, and standardized measures to gather patient-reported outcomes for many health domains, including depression, independent of patient condition. Most studies confirming the performance of these measures were conducted with a consented, volunteer study population for testing. Using a study population that has undergone the process of informed consent may be differentiated from the validation group because they are educated specifically as to the purpose of the questions and they will not have answers recorded in their permanent health record. (1) When given as part of routine practice to an orthopaedic population, do PROMIS Physical Function and Depression item banks produce score distributions different than those produced by the populations used to calibrate and validate the item banks? (2) Does the presence of a nonnormal distribution in the PROMIS Depression scores in a clinical population reflect a deliberately hasty answering of questions by patients? (3) Are patients who are reporting minimal depressive symptoms by scoring the minimum score on the PROMIS Depression Computer Adaptive Testing (CAT) distinct from other patients according to demographic data or their scores on other PROMIS assessments? Univariate descriptive statistics and graphic histograms were used to describe the frequency distribution of scores for the Physical Function and Depression item banks for all orthopaedic patients 18 years or older who had an outpatient visit between June 2015 and December 2016. The study population was then broken into two groups based on whether they indicated a lack of depressive symptoms and scored the minimum score (34.2) on the Depression CAT assessment (Floor Group) or not (Standard Group). The distribution of Physical Function CAT scores was compared between the two groups. Finally, a time-per-question value was calculated for both the Physical Function and Depression CATs and was compared between assessments within each group as well as between the two groups. Bivariate statistics compared the demographic data between the two groups. Physical Function CAT scores in musculoskeletal patients were normally distributed like the distribution calibration population; however, the score distribution of the Depression CAT in musculoskeletal patients was nonnormal with a spike in the floor score. After excluding the floor spike, the distribution of the Depression CAT scores was not different from the population control group. Patients who scored the floor score on the Depression CAT took slightly less time per question for Physical Function CAT when compared with other musculoskeletal patients (floor patients: 11 ± 9 seconds; normally distributed patients: 12 ± 10 seconds; mean difference: 1 second [0.8-1.1]; p < 0.001 but not clinically relevant). They spent a substantially shorter amount of time per question on the Depression CAT (Floor Group: 4 ± 3 seconds; Standard Group: 7 ± 7 seconds; mean difference: 3 [2.9-3.2]; p < 0.001). Patients who scored the minimum score on the PROMIS Depression CAT were younger than other patients (Floor Group: 50 ± 18 SD; Standard Group: 55 ± 16 SD; mean difference: 4.5 [4.2-4.7]; p < 0.001) with a larger percentage of men (Floor Group: 48.8%; Standard Group 40.0%; odds ratio 0.6 [0.6-0.7]; p < 0.001) and minor differences in racial breakdown (Floor Group: white 85.2%, black 11.9%, other 0.03%; Standard Group: white 83.9%, black 13.7%, other 0.02%). In an orthopaedic surgery population that is given PROMIS CAT as part of routine practice, the Physical Function item bank had a normal performance, but there is a group of patients who hastily complete Depression questions producing a strong floor effect and calling into question the validity of those floor scores that indicate minimal depression. Level II, diagnostic study.
NASA Technical Reports Server (NTRS)
Stimpert, D. L.
1973-01-01
A lift fan exhaust suppression system to meet future VTOL aircraft noise goals was designed and tested. The test vehicle was a 1.3 pressure ratio, 36 inch (91.44 cm) diameter lift fan with two chord rotor to stator spacing. A two splitter fan exhaust suppression system thirty inches (76.2 cm) long achieved 10 PNdB exhaust suppression in the aft quadrant compared to a design value of 20 PNdB. It was found that a broadband noise floor limited the realizable suppression. An analytical investigation of broadband noise generated by flow over the treatment surfaces provided very good agreement with the measured suppression levels and noise floor sound power levels. A fan thrust decrement of 22% was measured for the fully suppressed configuration of which 11.1% was attributed to the exhaust suppression hardware.
Environmental monitoring in a laboratory animal facility.
Wellstood-Nuesse, S; Shields, R P
1976-08-01
A study was made of the microbial environmental status of an animal facility. Cultures were made of animal and surgical room floors; the germicidal effectiveness of the phenolic disinfectant-detergent employed in the facility was tested against standard test organisms as well as against other microorganisms isolated from the facility, and killing power of the disinfectant-detergent was evaluated during various steps of the usual cleaning procedures, ie, mops and mop bucket solutions were tested before, during, and after mopping a room. It was found that colony counts for animal rooms cleaned with a chlorhexidine disinfectant were much lower than those cleaned with a phenolic disinfectant. The phenolic disinfectant killed some organisms after 10 min exposure, but no others. Pseudomonads were the most resistant organisms. Contaminated mops and mop bucket solutions appeared responsible for the high counts on floors cleaned with the phenolic disinfectant. Guidelines for achievable levels of cleanliness were suggested.
Vásquez, N; Knight, S L; Susser, J; Gall, A; Ellaway, P H; Craggs, M D
2015-12-01
Two case studies. To determine whether 6 weeks of regular pelvic floor muscle training (PFMT) can improve the strength and endurance of voluntary contractions in incomplete spinal cord injury and reduce neurogenic detrusor over-activity (NDO) and incontinence. The London Spinal Cord Injury Centre, Stanmore, London, UK. A 6-week programme of PFMT was conducted in two male subjects with stable supra-sacral motor incomplete (AIS C and D) spinal cord injuries. Clinical evaluations before and after training comprised measures of strength and endurance of voluntary pelvic floor contractions both objectively by anal canal-pressure measurements and subjectively using the modified Oxford grading system. NDO was determined by standard urodynamic tests of bladder function and incontinence measured by the International Consultation on Incontinence Questionnaire-Urology. Both subjects improved the strength and endurance of their pelvic floor muscle contractions by over 100% at the end of training. After training, Subject 1 (AIS D) was able to reduce bladder pressure during over-activity almost completely by voluntarily contracting the pelvic floor muscles. Subject 2 (AIS C) achieved a lesser reduction overall after training. Continence improved only in subject 1. These case studies provide evidence that a 6-week programme of PFMT may have a beneficial effect on promoting voluntary control of NDO and reduce incontinence in selected cases with a motor incomplete spinal cord lesion.
Improvement of Space Shuttle Main Engine Low Frequency Acceleration Measurements
NASA Technical Reports Server (NTRS)
Stec, Robert C.
1999-01-01
The noise floor of low frequency acceleration data acquired on the Space Shuttle Main Engines is higher than desirable. Difficulties of acquiring high quality acceleration data on this engine are discussed. The approach presented in this paper for reducing the acceleration noise floor focuses on a search for an accelerometer more capable of measuring low frequency accelerations. An overview is given of the current measurement system used to acquire engine vibratory data. The severity of vibration, temperature, and moisture environments are considered. Vibratory measurements from both laboratory and rocket engine tests are presented.
57. ORIGINAL TILE PRESS AND EXPERIMENTAL DENTAL KILN, SECOND FLOOR, ...
57. ORIGINAL TILE PRESS AND EXPERIMENTAL DENTAL KILN, SECOND FLOOR, NORTH WING, HENRY MERCER USED THE KILN FOR HIS EARLIEST GLAZE TESTS. THE PRESS WAS DESIGNED TO BE USED WITH METAL CASED MOLDS. SINCE ONLY THE EARLIEST TILE DESIGNS ARE IN METAL CASES. THIS TECHNIQUE WAS PROBABLY DISCONTINUED. THIS PRESS WAS, THEREFORE, PROBABLY NOT USED EXTENSIVELY AT THIS SITE. THE UPPER PART OF GLAZE KILN No. 2 IS AT THE LEFT REAR. - Moravian Pottery & Tile Works, Southwest side of State Route 313 (Swamp Road), Northwest of East Court Street, Doylestown, Bucks County, PA
Essential roles of fibronectin in the development of the left-right embryonic body plan.
Pulina, Maria V; Hou, Shuan-Yu; Mittal, Ashok; Julich, Dorthe; Whittaker, Charlie A; Holley, Scott A; Hynes, Richard O; Astrof, Sophie
2011-06-15
Studies in Xenopus laevis suggested that cell-extracellular matrix (ECM) interactions regulate the development of the left-right axis of asymmetry; however, the identities of ECM components and their receptors important for this process have remained unknown. We discovered that FN is required for the establishment of the asymmetric gene expression pattern in early mouse embryos by regulating morphogenesis of the node, while cellular fates of the nodal cells, canonical Wnt and Shh signaling within the node were not perturbed by the absence of FN. FN is also required for the expression of Lefty 1/2 and activation of SMADs 2 and 3 at the floor plate, while cell fate specification of the notochord and the floor plate, as well as signaling within and between these two embryonic organizing centers remained intact in FN-null mutants. Furthermore, our experiments indicate that a major cell surface receptor for FN, integrin α5β1, is also required for the development of the left-right asymmetry, and that this requirement is evolutionarily conserved in fish and mice. Taken together, our studies demonstrate the requisite role for a structural ECM protein and its integrin receptor in the development of the left-right axis of asymmetry in vertebrates. Copyright © 2011 Elsevier Inc. All rights reserved.
Radon mitigation at Birch Cliff Public School.
Moridi, R; Becker, E
1996-01-01
In 1991, Canadian Institute for Radiation Safety (CAIRS) conducted a radon screening program in all Metropolitan Toronto public schools. Birch Cliff Public School had a radon progeny level higher than the action level of 4.16 x 10(-7) Jm-3 (20 mWL). Follow-up radon testing was carried out at the school. Locations on the ground floor and in the basement were tested. All locations on the ground floor had radon progeny levels below the action level. Six locations in the basement had readings above the action level. All cracks and openings in the basement were sealed and a new heating/ventilating (HV) system for the basement was designed and installed. Then, the basement was tested again. Radon progeny levels are now well below the action level with an average of 7.43 x 10(-8) Jm-3 (3.57 mWL). This is about one fifth of the average radon progeny level found in the first stage of follow-up testing.
McClurg, D; Ashe, R G; Lowe-Strong, A S
2008-01-01
Lower urinary tract dysfunction affects up to 75% of the multiple sclerosis population. Results from our recent Pilot Study (McClurg et al., 2006) indicated that a combined programme of pelvic floor muscle training, electromyography biofeedback and neuromuscular electrical stimulation modalities may alleviate some of the distressing symptoms within this population. This clinical trial aimed to evaluate further the efficacy of these interventions and to establish the benefit of neuromuscular electrical stimulation above and beyond that of EMG biofeedback and pelvic floor muscle training. 74 multiple sclerosis patients who presented with lower urinary tract dysfunction were randomly allocated to one of two groups - Group 1 received Pelvic Floor Muscle Training, Electromyography Biofeedback and Placebo Neuromuscular Electrical Stimulation (n=37), and Group 2 which received Pelvic Floor Muscle Training, Electromyography Biofeedback, and Active Neuromuscular Electrical Stimulation (n=37). Treatment was for nine weeks with outcome measures recorded at weeks 0, 9, 16 and 24. The Primary Outcome Measure was the number of leakage episodes. Within group analysis was by Paired Samples t-test. Group differences were analysed using Repeated Measures Analysis of Variance and Post-hoc tests were used to determine the significance of differences between Groups at each time point. The mean number of incontinence episodes were reduced in Group 2 by 85% (p=0.001) whereas in Group 1 a lesser reduction of 47% (p=0.001) was observed. However, there was a statistically superior benefit in Group 2 when compared to Group 1 (p=0.0028). This superior benefit was evident in all other outcome measures. The addition of Active Neuromuscular Electrical Stimulation to a programme of Pelvic Floor Muscle Training and Electromyography Biofeedback should be considered as a first-line option in alleviating some of the symptoms of lower urinary tract dysfunction associated with multiple sclerosis. (c) 2007 Wiley-Liss, Inc.
Characteristics of Tornado-Like Vortices Simulated in a Large-Scale Ward-Type Simulator
NASA Astrophysics Data System (ADS)
Tang, Zhuo; Feng, Changda; Wu, Liang; Zuo, Delong; James, Darryl L.
2018-02-01
Tornado-like vortices are simulated in a large-scale Ward-type simulator to further advance the understanding of such flows, and to facilitate future studies of tornado wind loading on structures. Measurements of the velocity fields near the simulator floor and the resulting floor surface pressures are interpreted to reveal the mean and fluctuating characteristics of the flow as well as the characteristics of the static-pressure deficit. We focus on the manner in which the swirl ratio and the radial Reynolds number affect these characteristics. The transition of the tornado-like flow from a single-celled vortex to a dual-celled vortex with increasing swirl ratio and the impact of this transition on the flow field and the surface-pressure deficit are closely examined. The mean characteristics of the surface-pressure deficit caused by tornado-like vortices simulated at a number of swirl ratios compare well with the corresponding characteristics recorded during full-scale tornadoes.
An assessment of formaldehyde emissions from laminate flooring manufactured in China.
Pierce, Jennifer S; Abelmann, Anders; Lotter, Jason T; Ruestow, Peter S; Unice, Kenneth M; Beckett, Evan M; Fritz, Heidi A; Bare, Jennifer L; Finley, Brent L
2016-11-01
Formaldehyde emissions from two laminate flooring products, labeled as California Air Resources Board (CARB) compliant, were evaluated. Passive 24-hr samples (n = 79) and real-time measurements were collected following installation and removal of the products in two rooms of similar size. Mean formaldehyde concentrations following installation were 0.038 and 0.022 ppm for Products 1 and 2 respectively, and 7 days after flooring removal the concentrations returned to background pre-installation levels. Both products were also evaluated in a small chamber (ASTM D6007) using Deconstructive (de-laminated product) and Non-Deconstructive (intact product) methods. Deconstructive testing showed that Product 1 exceeded the applicable CARB emission standard by 4-fold, while Product 2 was equivalent to the standard. Non-Deconstructive measurements were far below the Deconstructive results and were used to predict 24-hr steady-state room air concentrations. Based on the products that we tested (one of which was found to not be compliant with the CARB standard), the airborne formaldehyde concentrations measured following installation in a real-world setting would not be expected to elicit adverse acute health effects. Copyright © 2016 Elsevier Inc. All rights reserved.
Electronic system for floor surface type detection in robotics applications
NASA Astrophysics Data System (ADS)
Tarapata, Grzegorz; Paczesny, Daniel; Tarasiuk, Łukasz
2016-11-01
The paper reports a recognizing method base on ultrasonic transducers utilized for the surface types detection. Ultra-sonic signal is transmitted toward the examined substrate, then reflected and scattered signal goes back to another ultra-sonic receiver. Thee measuring signal is generated by a piezo-electric transducer located at specified distance from the tested substrate. The detector is a second piezo-electric transducer located next to the transmitter. Depending on thee type of substrate which is exposed by an ultrasonic wave, the signal is partially absorbed inn the material, diffused and reflected towards the receiver. To measure the level of received signal, the dedicated electronic circuit was design and implemented in the presented systems. Such system was designed too recognize two types of floor surface: solid (like concrete, ceramic stiles, wood) and soft (carpets, floor coverings). The method will be applied in electronic detection system dedicated to autonomous cleaning robots due to selection of appropriate cleaning method. This work presents the concept of ultrasonic signals utilization, the design of both the measurement system and the measuring stand and as well number of wide tests results which validates correctness of applied ultrasonic method.
IMPACT OF VAGINAL PARITY AND AGING ON THE ARCHITECTURAL DESIGN OF PELVIC FLOOR MUSCLES
Alperin, Marianna; Cook, Mark; Tuttle, Lori J.; Esparza, Mary C.; Lieber, Richard L.
2016-01-01
Background Vaginal delivery and aging are key risk factors for pelvic floor muscle dysfunction, which is a critical component of pelvic floor disorders. However, alterations in the PFM intrinsic structure due to childbirth and aging that lead to muscle dysfunction remain elusive. Objectives To determine the impact of vaginal deliveries and aging on human cadaveric PFM architecture, the strongest predictor of active muscle function. Study Design Coccygeus, iliococcygeus and pubovisceralis were obtained from younger, ≤ 51 years, vaginally nulliparous (N=5) and vaginally parous (N=6), and older, >51 years, vaginally nulliparous (N=6) and vaginally parous (N=6) donors without history of PFDs. Architectural parameters, predictive of muscle’s excursion and force-generating capacity, were determined using validated methods. Intramuscular collagen content was quantified by hydroxyproline assay. Main effects of parity and aging and the interactions were determined using two-way ANOVA, with Tukey’s post-hoc testing with significance level of 0.05. Results The mean age of younger and older donors differed by ~40 years (P=0.001), but was similar between nulliparous and parous donors within each age group (P>0.9). Median parity was 2 (range 1–3) in younger and older vaginally parous groups, P=0.7. The main impact of parity was increased fiber length in the more proximal coccygeus (P=0.03), and iliococcygeus (P=0.04). Aging changes manifested as decreased physiological cross sectional area across all pelvic floor muscles, P<0.05, which substantially exceeded the age-related decline in muscle mass. Physiological cross sectional area was lower in younger vaginally parous, compared to younger vaginally nulliparous pelvic floor muscles, however the differences did not reach statistical significance. Pelvic floor muscles’ collagen content was not altered by parity, but increased dramatically with aging, P<0.05. Conclusions Increased fiber length in more proximal pelvic floor muscles likely represents an adaptive response to the chronically increased load placed on these muscles by the displaced apical structures, presumably as a consequence of vaginal delivery. In younger specimens, a consistent trend towards decrease in force generating capacity of all pelvic floor muscles in parous group suggests a potential mechanism for clinically identified pelvic floor muscle weakness in vaginally parous women. The substantial decrease in predicted muscle force production and fibrosis with aging represent likely mechanisms for the pelvic floor muscle dysfunction in older women. PMID:26953079
Brain Mechanisms Underlying Urge Incontinence and its Response to Pelvic Floor Muscle Training.
Griffiths, Derek; Clarkson, Becky; Tadic, Stasa D; Resnick, Neil M
2015-09-01
Urge urinary incontinence is a major problem, especially in the elderly, and to our knowledge the underlying mechanisms of disease and therapy are unknown. We used biofeedback assisted pelvic floor muscle training and functional brain imaging (functional magnetic resonance imaging) to investigate cerebral mechanisms, aiming to improve the understanding of brain-bladder control and therapy. Before receiving biofeedback assisted pelvic floor muscle training functionally intact, older community dwelling women with urge urinary incontinence as well as normal controls underwent comprehensive clinical and bladder diary evaluation, urodynamic testing and brain functional magnetic resonance imaging. Evaluation was repeated after pelvic floor muscle training in those with urge urinary incontinence. Functional magnetic resonance imaging was done to determine the brain reaction to rapid bladder filling with urgency. Of 65 subjects with urge urinary incontinence 28 responded to biofeedback assisted pelvic floor muscle training with 50% or greater improvement of urge urinary incontinence frequency on diary. However, responders and nonresponders displayed 2 patterns of brain reaction. In pattern 1 in responders before pelvic floor muscle training the dorsal anterior cingulate cortex and the adjacent supplementary motor area were activated as well as the insula. After the training dorsal anterior cingulate cortex/supplementary motor area activation diminished and there was a trend toward medial prefrontal cortex deactivation. In pattern 2 in nonresponders before pelvic floor muscle training the medial prefrontal cortex was deactivated, which changed little after the training. In older women with urge urinary incontinence there appears to be 2 patterns of brain reaction to bladder filling and they seem to predict the response and nonresponse to biofeedback assisted pelvic floor muscle training. Moreover, decreased cingulate activation appears to be a consequence of the improvement in urge urinary incontinence induced by training while prefrontal deactivation may be a mechanism contributing to the success of training. In nonresponders the latter mechanism is unavailable, which may explain why another form of therapy is required. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Omenzetter, Piotr; Morris, Hugh; Worth, Margaret; Gaul, Andrew; Jager, Simon; Desgeorges, Yohann
2012-04-01
An innovative three-story timber building, using self-centering, post-tensioned timber shear walls as the main horizontal load resisting system and lightweight non-composite timber-concrete floors, has recently been completed in Nelson, New Zealand. It is expected to be the trailblazer for similar but taller structures to be more widely adopted. Performance based standards require an advanced understanding of building responses and in order to meet the need for in-situ performance data the building has been subjected to forced vibration testing and instrumented for continuous monitoring using a total of approximately 90 data channels to capture its dynamic and long-term responses. The first part of the paper presents a brief discussion of the existing research on the seismic performance of timber frame buildings and footfall induced floor vibrations. An outline of the building structural system, focusing on the novel design solutions, is then discussed. This is followed by the description of the monitoring system. The analysis of monitoring results starts with a discussion of the monitoring of long-term deformations. Next, the assessment of the floor vibration serviceability performance is outlined. Then, the forced vibration tests conducted on the whole building at different construction stages are reviewed. The system identification results from seismic shaking records are also discussed. Finally, updating of a finite element model of the building is conducted.
Cell separation technique in dilectrophoretic chip with bulk electrode
NASA Astrophysics Data System (ADS)
Iliescu, Ciprian; Tay, Francis E. H.; Xu, Guolin; Yu, Liming
2006-01-01
This paper presents a new technique for separation of two cell populations in a dielectrophoretic chip with bulk silicon electrode. A characteristic of the dielectrophoretic chip is its "sandwich" structure: glass/silicon/glass that generates a unique definition of the microfluidic channel with conductive walls (silicon) and isolating floor and ceiling (glass). The structure confers the opportunity to use the electrodes not only to generate a gradient of the electric field but also to generate a gradient of velocity of the fluid inside the channel. This interesting combination gives rise to a new solution for dielectrophoretic separation of two cell populations. The separation method consists of four steps. First, the microchannel is field with the cells mixture. Second, the cells are trapped in different locations of the microfluidic channel, the cell population which exhibits positive dielectrophoresis is trapped in the area where the distance between the electrodes is the minimum whilst, the other population that exhibit negative dielectrophoresis is trapped where the distance between electrodes is the maximum. In the next step, increasing the flow in the microchannel will result in an increased hydrodynamic force that sweeps the cells trapped by positive dielectrophoresis out of the chip. In the last step, the electric field is removed and the second population is sweep out and collected at the outlet. The device was tested for separation of dead yeast cells from live yeast cells. The paper presents analytical aspects of the separation method a comparative study between different electrode profiles and experimental results.
Influence of sports flooring and shoes on impact forces and performance during jump tasks.
Malisoux, Laurent; Gette, Paul; Urhausen, Axel; Bomfim, Joao; Theisen, Daniel
2017-01-01
We aim to determine the influence of sports floorings and sports shoes on impact mechanics and performance during standardised jump tasks. Twenty-one male volunteers performed ankle jumps (four consecutive maximal bounds with very dynamic ankle movements) and multi-jumps (two consecutive maximal counter-movement jumps) on force plates using minimalist and cushioned shoes under 5 sports flooring (SF) conditions. The shock absorption properties of the SF, defined as the proportion of peak impact force absorbed by the tested flooring when compared with a concrete hard surface, were: SF0 = 0% (no flooring), SF1 = 19%, SF2 = 26%, SF3 = 37% and SF4 = 45%. Shoe and flooring effects were compared using 2x5 repeated-measures ANOVA with post-hoc Bonferroni-corrected comparisons. A significant interaction between SF and shoe conditions was found for VILR only (p = 0.003). In minimalist shoes, SF influenced Vertical Instantaneous Loading Rate (VILR) during ankle jumps (p = 0.006) and multi-jumps (p<0.001), in accordance with shock absorption properties. However, in cushioned shoes, SF influenced VILR during ankle jumps only (p<0.001). Contact Time was the only additional variable affected by SF, but only during multi-jumps in minimalist shoes (p = 0.037). Cushioned shoes induced lower VILR (p<0.001) and lower Contact Time (p≤0.002) during ankle jumps and multi-jumps compared to minimalist shoes. During ankle jumps, cushioned shoes induced greater Peak Vertical Ground Reaction Force (PVGRF, p = 0.002), greater Vertical Average Loading Rate (p<0.001), and lower eccentric (p = 0.008) and concentric (p = 0.004) work. During multi-jumps, PVGRF was lower (p<0.001) and jump height was higher (p<0.001) in cushioned compared to minimalist shoes. In conclusion, cushioning influenced impact forces during standardised jump tasks, whether it was provided by the shoes or the sports flooring. VILR is the variable that was the most affected.
Influence of sports flooring and shoes on impact forces and performance during jump tasks
Urhausen, Axel; Bomfim, Joao
2017-01-01
We aim to determine the influence of sports floorings and sports shoes on impact mechanics and performance during standardised jump tasks. Twenty-one male volunteers performed ankle jumps (four consecutive maximal bounds with very dynamic ankle movements) and multi-jumps (two consecutive maximal counter-movement jumps) on force plates using minimalist and cushioned shoes under 5 sports flooring (SF) conditions. The shock absorption properties of the SF, defined as the proportion of peak impact force absorbed by the tested flooring when compared with a concrete hard surface, were: SF0 = 0% (no flooring), SF1 = 19%, SF2 = 26%, SF3 = 37% and SF4 = 45%. Shoe and flooring effects were compared using 2x5 repeated-measures ANOVA with post-hoc Bonferroni-corrected comparisons. A significant interaction between SF and shoe conditions was found for VILR only (p = 0.003). In minimalist shoes, SF influenced Vertical Instantaneous Loading Rate (VILR) during ankle jumps (p = 0.006) and multi-jumps (p<0.001), in accordance with shock absorption properties. However, in cushioned shoes, SF influenced VILR during ankle jumps only (p<0.001). Contact Time was the only additional variable affected by SF, but only during multi-jumps in minimalist shoes (p = 0.037). Cushioned shoes induced lower VILR (p<0.001) and lower Contact Time (p≤0.002) during ankle jumps and multi-jumps compared to minimalist shoes. During ankle jumps, cushioned shoes induced greater Peak Vertical Ground Reaction Force (PVGRF, p = 0.002), greater Vertical Average Loading Rate (p<0.001), and lower eccentric (p = 0.008) and concentric (p = 0.004) work. During multi-jumps, PVGRF was lower (p<0.001) and jump height was higher (p<0.001) in cushioned compared to minimalist shoes. In conclusion, cushioning influenced impact forces during standardised jump tasks, whether it was provided by the shoes or the sports flooring. VILR is the variable that was the most affected. PMID:29020108
Floors: Selection and Maintenance.
ERIC Educational Resources Information Center
Berkeley, Bernard
Flooring for institutional, commercial, and industrial use is described with regard to its selection, care, and maintenance. The following flooring and subflooring material categories are discussed--(1) resilient floor coverings, (2) carpeting, (3) masonry floors, (4) wood floors, and (5) "formed-in-place floors". The properties, problems,…
10 CFR 430.3 - Materials incorporated by reference.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Energy Efficiency and Renewable Energy, Building Technologies Program, 6th Floor, 950 L'Enfant Plaza, SW... B. (8) ASHRAE 103-1993, Methods of Testing for Annual Fuel Utilization Efficiency of Residential...) ASHRAE 116-1995 (RA 2005), Methods of Testing for Rating Seasonal Efficiency of Unitary Air Conditioners...
Vibration behaviour of foamed concrete floor with polypropylene and rise husk ash fibre
NASA Astrophysics Data System (ADS)
Azaman, N. A. Mohd; Ghafar, N. H. Abd; Ayub, N.; Ibrahim, M. Z.
2017-11-01
In the history of the construction industry, lightweight concrete or foamed concrete is a special concrete which can very useful in the construction sector because it is very lightweight and it can compact by itself at each angle of foamwork. Foamed concrete is one of lightweight concrete which widely used for floor construction due to its light weight and economic. The significant challenges in the floor design process are considering the vibration that needs improvements for the poor dynamic behaviour insulation. An alternative material to replace sand with certain amount of rice husk ash (RHA) and polypropylene was introduced. Research was determine the dynamic behavior of foam-polypropylene and foam-RHA concrete by using impact hammer test. The natural frequency for normal foamed concrete, 0.5 % of Polypropylene and 15% of RHA is 29.8 Hz, 29.3 Hz and 29.5 Hz respectively.
Effect of incremental filling technique on adhesion of light-cured resin composite to cavity floor.
Chikawa, Hirokazu; Inai, Norimichi; Cho, Eitetsu; Kishikawa, Ryuzo; Otsuki, Masayuki; Foxton, Richard M; Tagami, Junji
2006-09-01
The purpose of this study was to evaluate the effect of various incremental filling techniques on adhesion between composite and cavity floor using light-cured resin composite. Black ABS resin and hybrid resin composite were used as mold materials--instead of dentin--for the preparation of cavities, and standardized to 5x5x5 mm. Each cavity was then treated with a bonding system (Clearfil SE bond). Resin composite (Clearfil Photo Core) was placed on the bonding resin using different incremental filling techniques or in bulk and irradiated for a total of 80 seconds using a halogen light unit. Specimens were subjected to the micro-tensile bond test at a crosshead speed of 1 mm/min. Data were analyzed by two-way ANOVA. The results indicated that an incremental filling technique was more effective in improving adhesion to the cavity floor than a bulk filling technique.
ERIC Educational Resources Information Center
Ellis, Tom
2000-01-01
Examines tested techniques that can keep a school's carpeting in good condition. Cleaning with hot water extraction, removing spills and spots, handling emergency cleanups, and cleaning soft surface flooring are addressed. (GR)
Human Factors Evaluations of Two-Dimensional Spacecraft Conceptual Layouts
NASA Technical Reports Server (NTRS)
Kennedy, Kriss J.; Toups, Larry D.; Rudisill, Marianne
2010-01-01
Much of the human factors work done in support of the NASA Constellation lunar program has been with low fidelity mockups. These volumetric replicas of the future lunar spacecraft allow researchers to insert test subjects from the engineering and astronaut population and evaluate the vehicle design as the test subjects perform simulations of various operational tasks. However, lunar outpost designs must be evaluated without the use of mockups, creating a need for evaluation tools that can be performed on two-dimension conceptual spacecraft layouts, such as floor plans. A tool based on the Cooper- Harper scale was developed and applied to one lunar scenario, enabling engineers to select between two competing floor plan layouts. Keywords: Constellation, human factors, tools, processes, habitat, outpost, Net Habitable Volume, Cooper-Harper.
Meyer, Sascha R A; De Jonghe, Jos F M; Schmand, Ben; Ponds, Rudolf W H M
2018-05-16
Episodic memory tests need to determine the degree to which patients with moderate to severe memory deficits can still benefit from retrieval support. Especially in the case of Alzheimer's disease (AD), this may support health care to be more closely aligned with patients' memory capacities. We investigated whether the different measures of episodic memory of the Visual Association Test-Extended (VAT-E) can provide a more detailed and informative assessment on memory disturbances across a broad range of cognitive decline, from normal to severe impairment as seen in AD, by examining differences in floor effects. The VAT-E consists of 24 pairs of black-and-white line drawings. In a within-group design, we compared score distributions of VAT-E subtests in healthy elderly controls, mild cognitive impairment (MCI), and AD (n = 144), as well as in relation to global cognitive impairment. Paired associate recall showed a floor effect in 41% of MCI patients and 62% of AD patients. Free recall showed a floor effect in 73% of MCI patients and 84% of AD patients. Multiple-choice cued recognition did not show a floor effect in either of the patient groups. We conclude that the VAT-E covers a broad range of episodic memory decline in patients. As expected, paired associate recall was of intermediate difficulty, free recall was most difficult, and multiple-choice cued recognition was least difficult for patients. These varying levels of difficulty enable a more accurate determination of the level of retrieval support that can still benefit patients across a broad range of cognitive decline.
Botelho, Simone; Pereira, Larissa Carvalho; Marques, Joseane; Lanza, Ana Helena; Amorim, Cesar Ferreira; Palma, Paulo; Riccetto, Cassio
2013-06-01
The continence mechanisms depend on the integrity of the pelvic floor muscles. It is therefore important to find simple, reliable, and safe methods to assess its contractility in a clinical setting. This study aims to investigate if digital palpation of the pelvic floor muscles presents correlation with its electromyographic activity. The sample consisted of 307 women with mean age of 23.93 years, including 39 nulliparous, 117 primigravid pregnant, 64 primiparous, in post-vaginal delivery, and 87 primiparous women, in post-cesarean section delivery. The assessment consisted of both digital palpation and surface electromyography. One, and the same, highly skilled and experienced physiotherapist, who was able to classify the different grades of contractility accurately, performed digital palpation using the Modified Oxford Grading Scale. Surface electromyography was performed using an intravaginal probe. For electromyography evaluation, three contractions of 5 sec each were recorded, and an average of three Root Mean squares was considered for analysis. Spearman's Coefficient, Jonckheere-Terpstra Test, Kruskal-Wallis as well as Dunn Test were used for statistical analysis. The strong correlation found between the two methods (P < 0.001) indicates that both digital palpation and electromyography can be used in everyday practice, both for clinical use and scientific research, although both have their specific limitations and requirements to avoid the risk of biases. There was a correlation between pelvic floor muscle contractility measured by surface electromyography and by digital palpation. Both methods can be used to validate data in research and clinical setting. Copyright © 2012 Wiley Periodicals, Inc.
[Cultural adaptation of the female pelvic floor questionnaire (FPFQ) into French].
Deparis, J; Bonniaud, V; Desseauve, D; Guilhot, J; Masanovic, M; De Tayrac, R; Fauconnier, A; Fritel, X
2017-09-01
The Female Pelvic Floor Questionnaire (FPFQ) is a self-administered tool on pelvic floor function. Our aim was to carry out a cultural adaptation of the FPFQ into French and to assess its psychometric properties. After cross-cultural adaptation into French, acceptability and reliability of the questionnaire were assessed through a sample of 56 women in a test-retest. Discriminative construct validity was evaluated by comparing the results obtained by the FPFQ to those of other validated questionnaires. Longitudinal follow-up of the 282 pregnant women included in the PreNatal Pelvic floor Prevention trial (3PN) was used to analyze responsiveness. The proportion of missing data did not exceed 4 % for questions about bladder function, bowel function and pelvic organ prolapse; 10 % for issues related to sexual function. Question 9 was considered difficult to understand by 14 % of women. After rewriting, this issue was retested in a new sample of 52 women and presented no further problems. The intra-class correlation coefficient was greater than or equal to 0.7 for all domains during the test-retest. The FPFQ was strongly and significantly correlated (Spearman r>0.5) with the other validated questionnaires. The French version of FPFQ recorded changes in urinary and sexual symptoms for the women involved in 3PN trial with a standardized response mean equal to 0.83 and 0.44, respectively. The French version of the FPFQ is self-administered, reliable, valid, and can detect a change in symptoms during follow-up. Level 4. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Dijkstra-Eshuis, Joke; Van den Bos, Tine W L; Splinter, Rosa; Bevers, Rob F M; Zonneveld, Willemijn C G; Putter, Hein; Pelger, Rob C M; Voorham-van der Zalm, Petra J
2015-02-01
Laparoscopic radical prostatectomy (LARP) may cause stress urinary incontinence (SUI). This study reports the effects of preoperative pelvic floor muscle therapy (PFMT) on SUI and quality of life (QoL) in men undergoing LARP. In this single-center randomized controlled trial, 122 patients undergoing LARP were assigned to an intervention group of PFMT with biofeedback once a week preoperatively, with 4 weeks' follow-up or to a control group receiving standard care. Randomization and allocation to the trial group were carried out by a central computer system. The primary analysis was based on 121 (n = 65; n = 56), comparing SUI rates and QoL in the two groups in a 1-year follow-up. Validated questionnaires, the Pelvic Floor Inventories (PeLFls), the King's Health Questionnaire (KHQ), the International Prostate Symptom Score (IPSS), a bladder diary, a 24-hr pad test and pelvic floor examination were used. Continence was defined as no leakage at all. All analyses were performed according to intention-to-treat. One hundred twenty-two patients were randomized, 19 patients were excluded from analysis because of early drop-out. There were no significant differences between both groups in the incidence of SUI and QoL based on the KHQ, IPSS, and pad tests (P ≥ 0.05). In all patients continence was achieved in 77.2% at 1 year postoperatively. Preoperative PFMT does not appear to be effective in the prevention of SUI and QoL following LARP. © 2014 Wiley Periodicals, Inc.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-20
... anthropomorphic test dummy (ATD) or its equivalent, undeformed floor, no yaw, and with all lateral structural... Side Facing Seat Dynamic Test Requirements AGENCY: Federal Aviation Administration (FAA), DOT. ACTION... installation of a single-place side facing seat on Embraer S.A. EMB 500 aircraft. Side- facing seats are...
Masten Space Systems’ Completes Test of Surface Sampling Technology
2018-06-13
Honeybee Robotics in Pasadena, California, flight tested its pneumatic sampler collection system, PlanetVac, on Masten Space Systems’ Xodiac rocket on May 24, launching from Mojave, California, and landing to collect a sample of more than 320 grams of top soil from the surface of the desert floor. NASA Flight Opportunities program funded the test flight.
30 CFR 7.67 - Construction test.
Code of Federal Regulations, 2014 CFR
2014-07-01
... § 7.66. (a) Test procedures. (1) The blasting unit shall be dropped 20 times from a height of 3 feet... each time in an attempt to have a different surface, corner, or edge strike the floor first for each... shall be submerged in 1 foot of water for 1 hour in each of 3 tests. The water temperature shall be...
A Field Test for Upper Body Strength and Endurance.
ERIC Educational Resources Information Center
Nelson, Jack K.; And Others
1991-01-01
Researchers studied the reliability of the modified push-up test in measuring upper body strength and endurance in elementary through college students. It also examined the accuracy of partner scoring. The test proved much easier to administer than the regular floor push-up. It was valid and reliable for all students and suitable for partner…
Does pelvic floor muscle contraction early after delivery cause perineal pain in postpartum women?
Neels, Hedwig; De Wachter, Stefan; Wyndaele, Jean-Jacques; Wyndaele, Michel; Vermandel, Alexandra
2017-01-01
Pelvic floor muscle training is effective and necessary in the prevention and treatment of pelvic floor dysfunction during pregnancy and after childbirth. But because of the high prevalence of perineal pain observed in women after childbirth, many women and caregivers fear to start pelvic floor muscle training immediately after childbirth. However, it is unknown whether pelvic floor muscle contractions (PFMC) provoke perineal pain in women shortly after childbirth. Therefore, the main objective is to study whether PFMC performed immediately after childbirth is painful or not. Observational longitudinal study. Perineal pain was assessed (1-6 days and 9 weeks postpartum) using a visual analogue scale (VAS 0-10) during PFMC and during several activities of daily living (ADL), during micturition and defecation. Descriptive statistics, Wilcoxon and McNemar tests were used. A total of 233 women participated (148 primiparous and 85 multiparous). Immediately postpartum the prevalence and intensity of pain during ADL (73%; VAS 4.9 (±2.3)), micturition (47%; VAS 3.4 (±1.7)) and defecation (19%; VAS 3.6 (±2.2)) were significantly higher (all p<0.000) than during PFMC (8%; VAS 2.2 (±0.9)). At 9 weeks postpartum, 30% experienced perineal pain during sexual intercourse (VAS 4.6 +/- 2.3) and 18% during defecation (VAS 4.7 +/- 2.3), but none during PFMC. Perineal pain is highly prevalent immediately after childbirth during ADL, micturition and defecation, but not during PFMC (only 8%). In case perineal pain occurs during PFMC, the intensity of pain is low (VAS 2). These results show that fear of perineal pain should not discourage women to start pelvic floor muscle training shortly after childbirth. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Reducing ingress of organic vapours into homes situated on contaminated land.
Crump, D; Brown, V; Rowley, J; Squire, R
2004-04-01
The efficacy of current landfill gas and radon mitigation measures for the prevention of ingress of organic vapours was investigated by the study of four houses situated on contaminated land in North West England. The chemical present in the ground of greatest concern for health due to exposure to vapour in the indoor air was hexachlorobutadiene (HCBD) and the concentration of this compound was used to assess the effectiveness of the remedial measures. A two stage remediation was undertaken. For a house with a solid floor the top surface of the floor was sealed and then for the second stage a fan was used to pressurise the soil gas beneath the house. In a house with a suspended timber floor, extra air bricks were installed to increase ventilation of the floor void and then a fan to further increase air exchange in the void. HCBD in air was monitored by both pumped and diffusive sampling methods. Control houses were also monitored that were not subject to remediation. It is concluded that the remedial measures used for radon protection of a suspended floor have the potential to reduce indoor HCBD concentrations by about 80%, at least in downstairs rooms (where initial levels were highest). The two techniques used for properties with solid floors do not appear to be as effective, and no benefit at all was seen without making allowances for changes in concentration that occurred in the control house over the same period. Further work is required to test the efficacy of the techniques over a longer period and under different circumstances of type of contamination and building characteristics.
Meyer, Sascha R A; Spaan, Pauline E J; Boelaarts, Leo; Ponds, Rudolf W H M; Schmand, Ben; de Jonghe, Jos F M
2016-09-01
Repeated measurements of episodic memory are needed for monitoring amnestic mild cognitive impairment (aMCI) and mild Alzheimer's disease (AD). Most episodic memory tests may pose a challenge to patients, even when they are in the milder stages of the disease. This cross-sectional study compared floor effects of the Visual Association Test (VAT) and the Rey Auditory Verbal Learning Test (RAVLT) in healthy elderly controls and in patients with aMCI or AD (N = 125). A hierarchical multiple regression analysis was used to examine whether linear or quadratic trends best fitted the data of cognitive test performance across global cognitive impairment. Results showed that VAT total scores decreased linearly across the range of global cognitive impairment, whereas RAVLT total scores showed a quadratic trend, with total scores levelling off for 90% of aMCI patients and 94% of AD patients. We conclude that the VAT shows few if any floor effects in patients with aMCI and mild AD and is therefore a potentially promising cognitive test for monitoring episodic memory impairment.
Clausen, Per Axel; Hansen, Vivi; Gunnarsen, Lars; Afshari, Alireza; Wolkoff, Peder
2004-05-01
The emission of di-2-ethylhexyl phthalate (DEHP) from a PVC flooring was studied for up to 472 days in both the FLEC (Field and Laboratory Emission Cell) and the CLIMPAQ (Chamberfor Laboratory Investigations of Materials, Pollution, and Air Quality). The loading of the CLIMPAQs was varied but was constant in the FLECs. The sorption properties of FLEC and CLIMPAQ were investigated using different methods. In addition, the uptake of DEHP by office floor dust on the PVC flooring was studied in CLIMPAQ experiments. The concentration versus time curves in both FLECs and CLIMPAQs increased slowly over about 150 days and reached a quasi-static equilibrium at 1 microg m(-3). The main conclusions were that (i) the emission rate of DEHP was limited by gas-phase mass transport and (ii) the dust layer increased the emission rate by increasing the external concentration gradient above the surface of the PVC. These conclusions were based on the facts that the specific emission rate was inversely proportional to the loading and that the dust had sorbed about four times as much DEHP over a 68-day period as emitted in the gas-phase experiments. About one-half of the emitted DEHP was deposited on the internal surfaces of both the FLEC and the CLIMPAQ.
Zero Emission Bay Area (ZEBA) Fuel Cell Bus Demonstration Results. Fourth Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eudy, Leslie; Post, Matthew
This report presents results of a demonstration of fuel cell electric buses (FCEB) operating in Oakland, California. Alameda-Contra Costa Transit District (AC Transit) leads the Zero Emission Bay Area (ZEBA) demonstration, which includes 12 advanced-design fuel cell buses and two hydrogen fueling stations. The FCEBs in service at AC Transit are 40-foot, low-floor buses built by Van Hool with a hybrid electric propulsion system that includes a US Hybrid fuel cell power system and EnerDel lithium-based energy storage system. The buses began revenue service in May 2010.
Fuel cell drives for road vehicles
NASA Astrophysics Data System (ADS)
Charnah, R. M.
For fuel-cell driven vehicles, including buses, the fuel cell may be the main, determining factor in the system but must be integrated into the complete design process. A Low-Floor Bus design is used to illustrate this point. The influence of advances in drive-train electronics is illustrated as are novel designs for motors and mechanical transmission of power to the wheels allowing the use of novel hub assemblies. A hybrid electric power system is being deployed in which Fuel Cells produce the energy needs but are coupled with batteries especially for acceleration phases and for recuperative braking.
Varella, Larissa Ramalho Dantas; Torres, Vanessa Braga; Angelo, Priscylla Helouyse Melo; Eugênia de Oliveira, Maria Clara; Matias de Barros, Alef Cavalcanti; Viana, Elizabel de Souza Ramalho; Micussi, Maria Thereza de Albuquerque Barbosa Cabral
2016-01-01
[Purpose] The aim of the present study was to assess the influence of parity, type of delivery, and physical activity level on pelvic floor muscles in postmenopausal women. [Subjects and Methods] This was an observational analytic cross-sectional study with a sample of 100 postmenopausal women, aged between 45 and 65 years, divided into three groups according to menopausal stage: hysterectomized and early and late postmenopause. Patients were assessed for sociodemographic and gyneco-obstetric factors and subjected to a muscle strength test and perineometry. Descriptive statistics, ANOVA, Kruskal-Wallis and multiple regression were applied. [Results] The results showed homogeneity in sociodemographic and anthropometric characteristics. There was no difference in pelvic floor muscle function among the three groups. Type of delivery, parity and physical activity level showed no influence on muscle function. [Conclusion] The findings demonstrate that parity, type of delivery, and physical activity level had no influence on pelvic floor muscle pressure in postmenopausal women. One hypothesis to explain these results is the fact that the decline in muscle function in postmenopausal women is related to the female aging process. PMID:27134366
Experimental Investigation of SBLI to Unravel Inlet Unstart Physics
NASA Astrophysics Data System (ADS)
Funderburk, Morgan; Narayanaswamy, Venkateswaran
2016-11-01
The phenomenon of shock boundary layer interaction (SBLI) driven inlet unstart persists as one of the most significant problems facing supersonic ramjet/scramjet engines. In order to determine how the characteristics of the SBLI units specific to rectangular inlets evolve during an unstart event, an experimental investigation is made using surface streakline methods and pitot/wall pressure measurements in the vicinity of the floor and corner SBLI induced by a compression ramp in a rectangular channel. Mean and unsteady measurements were taken at a variety of shock strengths to simulate the evolution of the combustion-induced back pressure ratio during unstart. The freestream Mach number was also varied. Statistical correlation methods were used to determine the degree of interaction between the floor and corner SBLI with different flowfield locations for the various test conditions. Finally, comparison to a two-dimensional compression ramp SBLI was made to determine any modification caused by the introduction of the corner SBLI. Results indicate that the floor and corner SBLI transition from distinct units to members of a global separated flow with increasing back pressure, and that considerable modification of the floor SBLI by the corner flow occurs. AFOSR Grant FA9550-15-1-0296.
Impact data from a transport aircraft during a controlled impact demonstration
NASA Technical Reports Server (NTRS)
Fasanella, E. L.; Alfaro-Bou, E.; Hayduk, R. J.
1986-01-01
On December 1, 1984, the FAA and NASA conducted a remotely piloted air-to-ground crash test of a Boeing 720 transport aircraft instrumented to measure crash loads of the structure and the anthropomorphic dummy passengers. Over 330 time histories of accelerations and loads collected during the Full-Scale Transport Controlled Impact Demonstration (CID) for the 1-sec period after initial impact are presented. Although a symmetric 1 deg. nose-up attitude with a 17 ft/sec sink rate was planned, the plane was yawed and rolled 13 deg. at initial (left-wing) impact. The first fuselage impact occurred near the nose wheel well with the nose pitched down 2.5 deg. Peak normal (vertical) floor accelerations were highest in the cockpit and forward cabin near the nose wheel well and were approximately 14G. The remaining cabin floor received normal acceleration peaks of 7G or less. The peak longitudinal floor accelerations showed a similar distribution, with the highest (7G) in the cockpit and forward cabin, decreasing to 4G or less toward the rear. Peak transverse floor accelerations ranged from about 5G in the cockpit to 1G in the aft fuselage.
Johnston, J D; Kruman, B A; Nelson, M C; Merrill, R M; Graul, R J; Hoybjerg, T G; Tuttle, S C; Myers, S J; Cook, R B; Weber, K S
2017-09-01
Residential endotoxin exposure is associated with protective and pathogenic health outcomes. Evaporative coolers, an energy-efficient type of air conditioner used in dry climates, are a potential source of indoor endotoxins; however, this association is largely unstudied. We collected settled dust biannually from four locations in homes with evaporative coolers (n=18) and central air conditioners (n=22) in Utah County, Utah (USA), during winter (Jan-Apr) and summer (Aug-Sept), 2014. Dust samples (n=281) were analyzed by the Limulus amebocyte lysate test. Housing factors were measured by survey, and indoor temperature and relative humidity measures were collected during both seasons. Endotoxin concentrations (EU/mg) were significantly higher in homes with evaporative coolers from mattress and bedroom floor samples during both seasons. Endotoxin surface loads (EU/m 2 ) were significantly higher in homes with evaporative coolers from mattress and bedroom floor samples during both seasons and in upholstered furniture during winter. For the nine significant season-by-location comparisons, EU/mg and EU/m 2 were approximately three to six times greater in homes using evaporative coolers. A plausible explanation for these findings is that evaporative coolers serve as a reservoir and distribution system for Gram-negative bacteria or their cell wall components in homes. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Salivary mineral composition in patients with oral cancer.
Dziewulska, Anna; Janiszewska-Olszowska, Joanna; Bachanek, Teresa; Grocholewicz, Katarzyna
2013-01-01
To analyse the mineral content of saliva in patients with oral cancer in order to identify possible markers that might aid the diagnosis of oral cancer. The study group consisted of 34 patients, aged 35-72 years with a diagnosis of oral cancer, including seven women and 27 men, before the start of treatment. Samples of unstimulated saliva were collected in plastic containers. The concentrations of sodium and potassium were assessed using ion selective electrodes, and the concentrations of calcium, magnesium, iron and phosphorus were assessed using colorimetric methods. Statistically significant differences between the study and control groups were found only for the concentration of sodium--higher concentrations were found in the study group. When comparing different cancer localisations, the highest levels of salivary sodium were found in cases of cancer of the floor of the oral cavity, and the lowest levels in tongue or parotid gland cancer. The highest calcium levels were found in cancer of the floor of the oral cavity, and the lowest levels in tongue cancer. The highest levels of magnesium were found in cancer of the floor of the oral cavity, and the lowest in tongue cancer. As regards the different histological types, higher sodium and calcium levels were found in squamous cell carcinomas than in other types. Salivary mineral content in patients with oral squamous cell carcinoma is indicative of oral dehydration; however, we found no evidence of any salivary mineral markers that would be useful for the diagnosis of oral cancer.
Yu, Kwanha; McGlynn, Sean; Matise, Michael P
2013-04-01
Cell fate specification in the CNS is controlled by the secreted morphogen sonic hedgehog (Shh). At spinal cord levels, Shh produced by both the notochord and floor plate (FP) diffuses dorsally to organize patterned gene expression in dividing neural and glial progenitors. Despite the fact that two discrete sources of Shh are involved in this process, the individual contribution of the FP, the only intrinsic source of Shh throughout both neurogenesis and gliogenesis, has not been clearly defined. Here, we have used conditional mutagenesis approaches in mice to selectively inactivate Shh in the FP (Shh(FP)) while allowing expression to persist in the notochord, which underlies the neural tube during neurogenesis but not gliogenesis. We also inactivated Smo, the common Hh receptor, in neural tube progenitors. Our findings confirm and extend prior studies suggesting an important requirement for Shh(FP) in specifying oligodendrocyte cell fates via repression of Gli3 in progenitors. Our studies also uncover a connection between embryonic Shh signaling and astrocyte-mediated reactive gliosis in adults, raising the possibility that this pathway is involved in the development of the most common cell type in the CNS. Finally, we find that intrinsic spinal cord Shh signaling is required for the proper formation of the ependymal zone, the epithelial cell lining of the central canal that is also an adult stem cell niche. Together, our studies identify a crucial late embryonic role for Shh(FP) in regulating the specification and differentiation of glial and epithelial cells in the mouse spinal cord.
Volatile Organic Compounds Enhance Allergic Airway Inflammation in an Experimental Mouse Model
Bönisch, Ulrike; Böhme, Alexander; Kohajda, Tibor; Mögel, Iljana; Schütze, Nicole; von Bergen, Martin; Simon, Jan C.; Lehmann, Irina; Polte, Tobias
2012-01-01
Background Epidemiological studies suggest an association between exposure to volatile organic compounds (VOCs) and adverse allergic and respiratory symptoms. However, whether VOCs exhibit a causal role as adjuvants in asthma development remains unclear. Methods To investigate the effect of VOC exposure on the development of allergic airway inflammation Balb/c mice were exposed to VOCs emitted by new polyvinylchloride (PVC) flooring, sensitized with ovalbumin (OVA) and characterized in acute and chronic murine asthma models. Furthermore, prevalent evaporated VOCs were analyzed and mice were exposed to selected single VOCs. Results Exposure of mice to PVC flooring increased eosinophilic lung inflammation and OVA-specific IgE serum levels compared to un-exposed control mice. The increased inflammation was associated with elevated levels of Th2-cytokines. Long-term exposure to PVC flooring exacerbated chronic airway inflammation. VOCs with the highest concentrations emitted by new PVC flooring were N-methyl-2-pyrrolidone (NMP) and 2,2,4-trimethyl-1,3-pentanediol diisobutyrate (TXIB). Exposure to NMP or TXIB also increased the allergic immune response in OVA-sensitized mice. In vitro or in vivo exposure to NMP or TXIB reduced IL-12 production in maturing dendritic cells (DCs) and enhanced airway inflammation after adoptive DC transfer into Balb/c mice. At higher concentrations both VOCs induced oxidative stress demonstrated by increased isoprostane and glutathione-S-transferase-pi1 protein levels in the lung of non-sensitized mice. Treatment of PVC flooring-exposed mice with N-acetylcysteine prevented the VOC-induced increase of airway inflammation. Conclusions Our results demonstrate that exposure to VOCs may increase the allergic immune response by interfering with DC function and by inducing oxidative stress and has therefore to be considerate as risk factor for the development of allergic diseases. PMID:22802943
Volatile organic compounds enhance allergic airway inflammation in an experimental mouse model.
Bönisch, Ulrike; Böhme, Alexander; Kohajda, Tibor; Mögel, Iljana; Schütze, Nicole; von Bergen, Martin; Simon, Jan C; Lehmann, Irina; Polte, Tobias
2012-01-01
Epidemiological studies suggest an association between exposure to volatile organic compounds (VOCs) and adverse allergic and respiratory symptoms. However, whether VOCs exhibit a causal role as adjuvants in asthma development remains unclear. To investigate the effect of VOC exposure on the development of allergic airway inflammation Balb/c mice were exposed to VOCs emitted by new polyvinylchloride (PVC) flooring, sensitized with ovalbumin (OVA) and characterized in acute and chronic murine asthma models. Furthermore, prevalent evaporated VOCs were analyzed and mice were exposed to selected single VOCs. Exposure of mice to PVC flooring increased eosinophilic lung inflammation and OVA-specific IgE serum levels compared to un-exposed control mice. The increased inflammation was associated with elevated levels of Th2-cytokines. Long-term exposure to PVC flooring exacerbated chronic airway inflammation. VOCs with the highest concentrations emitted by new PVC flooring were N-methyl-2-pyrrolidone (NMP) and 2,2,4-trimethyl-1,3-pentanediol diisobutyrate (TXIB). Exposure to NMP or TXIB also increased the allergic immune response in OVA-sensitized mice. In vitro or in vivo exposure to NMP or TXIB reduced IL-12 production in maturing dendritic cells (DCs) and enhanced airway inflammation after adoptive DC transfer into Balb/c mice. At higher concentrations both VOCs induced oxidative stress demonstrated by increased isoprostane and glutathione-S-transferase-pi1 protein levels in the lung of non-sensitized mice. Treatment of PVC flooring-exposed mice with N-acetylcysteine prevented the VOC-induced increase of airway inflammation. Our results demonstrate that exposure to VOCs may increase the allergic immune response by interfering with DC function and by inducing oxidative stress and has therefore to be considerate as risk factor for the development of allergic diseases.
A new mechanism for calcium loss in forest-floor soils
Lawrence, G.B.; David, M.B.; Shortle, W.C.
1995-01-01
CALCIUM is the fifth most abundant element in trees, and is an essential component for wood formation and the maintenance of cell walls. Depletion of Ca from the rooting zone can result in acidification of soil1 and surface water2 and possibly growth decline and dieback of red spruce3,4. During the past six decades, concentrations of root-available Ca (exchangeable and acid-ex tract able forms) in forest-floor soils have decreased in the northeastern United States5,6. Both net forest growth and acid deposition have been put forth as mechanisms that can account for this Ca depletion5,6. Here, however, we present data collected in red spruce forests in the northeastern United States that are inconsistent with either of these mechanisms. We propose that aluminium, mobilized in the mineral soil by acid deposition, is transported into the forest floor in a reactive form that reduces storage of Ca, and thus its availability for root uptake. This results in potential stress to trees and, by increasing the demand for Ca, also decreases neutralization of drainage waters, thereby leading to acidification of lakes and streams.
Piezoresistive pressure sensor array for robotic skin
NASA Astrophysics Data System (ADS)
Mirza, Fahad; Sahasrabuddhe, Ritvij R.; Baptist, Joshua R.; Wijesundara, Muthu B. J.; Lee, Woo H.; Popa, Dan O.
2016-05-01
Robots are starting to transition from the confines of the manufacturing floor to homes, schools, hospitals, and highly dynamic environments. As, a result, it is impossible to foresee all the probable operational situations of robots, and preprogram the robot behavior in those situations. Among human-robot interaction technologies, haptic communication is an intuitive physical interaction method that can help define operational behaviors for robots cooperating with humans. Multimodal robotic skin with distributed sensors can help robots increase perception capabilities of their surrounding environments. Electro-Hydro-Dynamic (EHD) printing is a flexible multi-modal sensor fabrication method because of its direct printing capability of a wide range of materials onto substrates with non-uniform topographies. In past work we designed interdigitated comb electrodes as a sensing element and printed piezoresistive strain sensors using customized EHD printable PEDOT:PSS based inks. We formulated a PEDOT:PSS derivative ink, by mixing PEDOT:PSS and DMSO. Bending induced characterization tests of prototyped sensors showed high sensitivity and sufficient stability. In this paper, we describe SkinCells, robot skin sensor arrays integrated with electronic modules. 4x4 EHD-printed arrays of strain sensors was packaged onto Kapton sheets and silicone encapsulant and interconnected to a custom electronic module that consists of a microcontroller, Wheatstone bridge with adjustable digital potentiometer, multiplexer, and serial communication unit. Thus, SkinCell's electronics can be used for signal acquisition, conditioning, and networking between sensor modules. Several SkinCells were loaded with controlled pressure, temperature and humidity testing apparatuses, and testing results are reported in this paper.
Characterization of an Outdoor Ambient Radio Frequency Environment
2016-02-16
radio frequency noise ”) prior to testing of a specific system under test (SUT). With this characterization, locations can be selected to avoid RF...spectrum analyzer, ambient RF noise floor, RF interference 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT SAR 18...environment (sometimes referred to as “radio frequency noise ”) prior to testing of a specific system under test (SUT). With this characterization
16 CFR 1209.6 - Test procedures for critical radiant flux.
Code of Federal Regulations, 2011 CFR
2011-01-01
... radiant flux of exposed attic floor insulation using a radiant heat energy source. (a) Apparatus and... ACT REGULATIONS INTERIM SAFETY STANDARD FOR CELLULOSE INSULATION The Standard § 1209.6 Test procedures... radiant heat energy panel or equivalent panel inclined at 30° above and directed at a horizontally-mounted...
16 CFR 1209.6 - Test procedures for critical radiant flux.
Code of Federal Regulations, 2012 CFR
2012-01-01
... radiant flux of exposed attic floor insulation using a radiant heat energy source. (a) Apparatus and... ACT REGULATIONS INTERIM SAFETY STANDARD FOR CELLULOSE INSULATION The Standard § 1209.6 Test procedures... radiant heat energy panel or equivalent panel inclined at 30° above and directed at a horizontally-mounted...
16 CFR 1209.6 - Test procedures for critical radiant flux.
Code of Federal Regulations, 2014 CFR
2014-01-01
... radiant flux of exposed attic floor insulation using a radiant heat energy source. (a) Apparatus and... ACT REGULATIONS INTERIM SAFETY STANDARD FOR CELLULOSE INSULATION The Standard § 1209.6 Test procedures... radiant heat energy panel or equivalent panel inclined at 30° above and directed at a horizontally-mounted...
16 CFR 1209.6 - Test procedures for critical radiant flux.
Code of Federal Regulations, 2010 CFR
2010-01-01
... radiant flux of exposed attic floor insulation using a radiant heat energy source. (a) Apparatus and... ACT REGULATIONS INTERIM SAFETY STANDARD FOR CELLULOSE INSULATION The Standard § 1209.6 Test procedures... radiant heat energy panel or equivalent panel inclined at 30° above and directed at a horizontally-mounted...
NORTH BASEMENT WALL. IBEAM COLUMNS HAVE BEEN ENCASED IN CONCRETE. ...
NORTH BASEMENT WALL. I-BEAM COLUMNS HAVE BEEN ENCASED IN CONCRETE. STEEL BEAMS LAY ACROSS FIRST FLOOR AWAITING CONCRETE POUR. CAMERA LOOKS SOUTHWEST. INL NEGATIVE NO. 735. Unknown Photographer, 10/6/1950 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
2006-01-05
KENNEDY SPACE CENTER, FLA. - In NASA Kennedy Space Center’s Orbiter Processing Facility bay 3, a fuel cell removed from the orbiter Discovery is lowered toward the floor. Fuel cells are located under the forward portion of the payload bay. They make power for the orbiter by mixing hydrogen and oxygen to produce electricity. Fuel cells also create potable water that is pumped into storage tanks for the crew to use in orbit. Discovery is the designated orbiter for the second return-to-flight mission, STS-121, scheduled for launch in May. Photo credit: NASA/Kim Shiflett
Lorenzo Gómez, M F; Silva Abuín, J M; García Criado, F J; Geanini Yagüez, A; Urrutia Avisrror, M
2008-06-01
We analyze the pelvic floor muscles treatment outcomes by using biofeedback (BFB) with electromyography with superficial electrodes in women diagnosed as having stress urinary incontinence (SUI). Besides, we compare this treatment with pelvic floor muscle exercises (PFME) plus vaginal electrostimulation. 85 women with stress urinary incontinence, aged 42 - 74 years. We divided the patients in two groups: Group 1 (N = 50): This patients carry out a perineal biofeedback with superficial electrodes without electrostimulation, and Group 2 (N = 35): This patients were treated with pelvis floor muscle exercices and vaginal electrostimulation. All patients carry out two session per week (of 30 minutes each one) during ten weeks. We assess the outcomes through international urinary incontinence questionnaires (IU-5 and ICIQ-SF) and urinary incontinence related quality of life test (King's questionnaire). Student t-test and Fisher Exact test were used, p < 0.05 was considered statistically significant. No difference was found in the age average of both groups. 84% of patients of group 1 and 80% of patients of group 2 were cured with the treatment. We assumed they were cured when incontinence episodes not happened or they do not need to use absorbent materials. In the Group 1, 50% of patients in the fourth week and 84% in the tenth week were cured. In the Group 2, 71.42% of patients in the fourth week and 80% in the tenth week were cured. In the Group 2, eight patients (22.85%) complained side effects. Both groups improved the quality of life similarly. Grade 1 and grade 2 stress urinary incontinence treatment by using perineal biofeedback with superficial electrodes electromyography is better or similar to more invasive treatments. Also pelvic floor muscle exercices plus vaginal electrostimulation have good outcomes although some patients complain side effects. Both conservative treatments are effective and feasible.
Rivalta, Massimo; Sighinolfi, Maria Chiara; Micali, Salvatore; De Stefani, Stefano; Bianchi, Giampaolo
2010-03-01
Urinary incontinence (UI) is a debilitating condition that can cause discomfort, embarrassment, loss of confidence; it can lead to withdrawal from social life, and adversely affects physical and mental health, sexual function and quality of life (QoL) in women. The aim is to determine the impact of combined pelvic floor rehabilitation (PFR) on UI, female sexual dysfunction, and QoL. Female Sexual Function Index questionnaire (FSFI) and King's Health Questionnaire (KHQ). Sixteen patients with UI were selected and underwent a complete PFR program (biofeedback, functional electrical stimulation, pelvic floor muscles exercises, and vaginal cones). Patient filled out the FSFI questionnaire and the KHQ at the baseline and at follow-up. After PFR none of the patients reported urine leakage during sexual activity. Resolution of incontinence was achieved in 13 (81.25%) women. Only three (18.75%) patients had positive 1-hour pad test after the treatment. There was significant difference between pad test leakage before and after the PFR (P < 0.001). The mean Stamey incontinence score was 1.37 +/- 0.5 at the baseline vs. 0.25 +/- 0.57 at the follow up (P < 0.001). Before PFR, FSFI total score ranged from 25.8 to 2 (mean 14.65 +/- 6.88), after treatment the FSFI total score ranged from 36 to 2 (mean 22.65 +/- 9.5) (P < 0.001). The improvement of the scores in the six FSFI domains, 5 months after the conclusion of PFR, was statistically significant (desire, arousal, lubrication, orgasm, satisfaction, and pain). All the nine domains in the KHQ presented a low average score after treatment and the improvements were statistically significant. PFR led to a significant difference in the daily use of pads, 1-hour pad test, and Stamey incontinence scores. The treatment caused an improvement in patient's QoL index and sexual function.
Frequency and risk-factors analysis of Escherichia coli O157:H7 in Bali-cattle.
Suardana, I Wayan; Widiasih, Dyah Ayu; Nugroho, Widagdo Sri; Wibowo, Michael Haryadi; Suyasa, I Nyoman
2017-08-01
Cattle are known as the main reservoir of zoonotic agents verocytotoxin-producing Escherichia coli. These bacteria are usually isolated from calves with diarrhea and/or mucus and blood. Tolerance of these agents to the environmental conditions will strengthen of their transmission among livestock. A total of 238 cattle fecal samples from four sub-districts in Badung, Bali were used in this study. Epidemiological data observed include cattle age, sex, cattle rearing system, the source of drinking water, weather, altitude, and type of cage floor, the cleanliness of cage floor, the slope of cage floor, and the level of cattle cleanliness. The study was initiated by culturing of samples onto eosin methylene blue agar, then Gram stained, and tested for indole, methyl-red, voges proskauer, and citrate, Potential E.coli isolates were then cultured onto sorbitol MacConkey agar, and further tested using O157 latex agglutination test and H7 antisera. Molecular identification was performed by analysis of the 16S rRNA gene, and epidemiological data was analyzed using STATA 12.0 software. The results showed, the prevalence of E. coli O157:H7 in cattle at Badung regency was 6.30% (15/238) covering four sub districts i.e. Petang, Abiansemal, Mengwi, and Kuta which their prevalence was 8.62%(5/58), 10%(6/60), 3.33%(2/60), and 3.33(2/60)%, respectively. The analysis of 16S rRNA gene confirmed of isolates as an E. coli O157:H7 strain with 99% similarities. Furthermore, the risk factors analysis showed that the slope of the cage floor has a highly significant effect (P<0.05) to the distribution of infection. Consequently, implementing this factor must be concerned in order to decrease of infection. Copyright © 2017 Elsevier B.V. All rights reserved.
Tveter, Anne Therese; Dagfinrud, Hanne; Moseng, Tuva; Holm, Inger
2014-07-01
To provide reference values and reference equations for frequently used clinical field tests of health-related physical fitness for use in clinical practice. Cross-sectional design. General community. Convenience sample of volunteers (N=370) between 18 and 90 years of age were recruited from a wide range of settings (ie, work sites, schools, community centers for older adults) and different geographic locations (ie, urban, suburban, rural) in southeastern Norway. Not applicable. The participants conducted 5 clinical field tests (6-minute walk test, stair test, 30-second sit-to-stand test, handgrip test, fingertip-to-floor test). The results of the field tests showed that performance remained unchanged until approximately 50 years of age; after that, performance deteriorated with increasing age. Grip strength (79%), meters walked in 6 minutes (60%), and seconds used on the stair test (59%) could be well predicted by age, sex, height, and weight in participants ≥50 years of age, whereas the performance on all tests was less well predicted in participants <50 years of age. The reference values and reference equations provided in this study may increase the applicability and interpretability of the 6-minute walk test, stair test, 30-second sit-to-stand test, handgrip test, and fingertip-to-floor test in clinical practice. Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
The Use of Miniature Electret Microphones in Small Optoacoustic Cells.
1980-06-30
conductivity. The work-horse material has been carnauba wax (used in floor polishes), but shellac, sealing wax , and naphthalene have been used. Such...electret is normally short with large area working faces. * The typical electret material is an organic wax or plastic, a material of poor electrical
DOING Physics: Physics Activities for Groups.
ERIC Educational Resources Information Center
Zwicker, Earl, Ed.
1985-01-01
Recommends an experiment which will help students experience the physical evidence that floors, tables, and walls actually bend when pressure is exerted against them. Set-up includes: laser, radio, solar cell, and wall-mounted mirror. When the beam is moved by pressure on the wall, participants can "hear the wall bend." (DH)