The compatibility of consumer DLP projectors with time-sequential stereoscopic 3D visualisation
NASA Astrophysics Data System (ADS)
Woods, Andrew J.; Rourke, Tegan
2007-02-01
A range of advertised "Stereo-Ready" DLP projectors are now available in the market which allow high-quality flickerfree stereoscopic 3D visualization using the time-sequential stereoscopic display method. The ability to use a single projector for stereoscopic viewing offers a range of advantages, including extremely good stereoscopic alignment, and in some cases, portability. It has also recently become known that some consumer DLP projectors can be used for timesequential stereoscopic visualization, however it was not well understood which projectors are compatible and incompatible, what display modes (frequency and resolution) are compatible, and what stereoscopic display quality attributes are important. We conducted a study to test a wide range of projectors for stereoscopic compatibility. This paper reports on the testing of 45 consumer DLP projectors of widely different specifications (brand, resolution, brightness, etc). The projectors were tested for stereoscopic compatibility with various video formats (PAL, NTSC, 480P, 576P, and various VGA resolutions) and video input connections (composite, SVideo, component, and VGA). Fifteen projectors were found to work well at up to 85Hz stereo in VGA mode. Twenty three projectors would work at 60Hz stereo in VGA mode.
Dual throat thruster cold flow analysis
NASA Technical Reports Server (NTRS)
Lundgreen, R. B.; Nickerson, G. R.; Obrien, C. J.
1978-01-01
The concept was evaluated with cold flow (nitrogen gas) testing and through analysis for application as a tripropellant engine for single-stage-to-orbit type missions. Three modes of operation were tested and analyzed: (1) Mode 1 Series Burn, (2) Mode 1 Parallel Burn, and (3) Mode 2. Primary emphasis was placed on the Mode 2 plume attachment aerodynamics and performance. The conclusions from the test data analysis are as follows: (1) the concept is aerodynamically feasible, (2) the performance loss is as low as 0.5 percent, (3) the loss is minimized by an optimum nozzle spacing corresponding to an AF-ATS ratio of about 1.5 or an Le/Rtp ratio of 3.0 for the dual throat hardware tested, requiring only 4% bleed flow, (4) the Mode 1 and Mode 2 geometry requirements are compatible and pose no significant design problems.
A high resolution cavity BPM for the CLIC Test Facility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chritin, N.; Schmickler, H.; Soby, L.
2010-08-01
In frame of the development of a high resolution BPM system for the CLIC Main Linac we present the design of a cavity BPM prototype. It consists of a waveguide loaded dipole mode resonator and a monopole mode reference cavity, both operating at 15 GHz, to be compatible with the bunch frequencies at the CLIC Test Facility. Requirements, design concept, numerical analysis, and practical considerations are discussed.
An Evaluation of Alternative Delivery Modes for Information Services.
ERIC Educational Resources Information Center
Short, Craig; Christal, Melodie E.
The use of the floppy disk as an alternative mode for delivering Information Services reports was evaluated for fiscal year 1985 by the National Center for Higher Education Management Systems (NCHEMS). A 5.25 inch, 8/9 sector, 40 track ASCII floppy disk used under PC-DOS on the IBM PC and IBM PC compatible hardware was tested. Tabular data but not…
NASA Technical Reports Server (NTRS)
Wingard, Charles Doug; Munafo, Paul M. (Technical Monitor)
2001-01-01
In the International Space Station (ISS), astronauts will convert urine into potable water with the Urine Processor Assembly (UPA). The urine is distilled, with the concentrated form containing about 15% brine solids, and the dilute form as a blend of pre-treated urine/wastewater. Eighteen candidate non-metallic materials for use with the UPA were tested in 2000 for compatibility with the concentrated and dilute urine solutions for continuous times of at least 30 days, and at conditions of 0.5 psia pressure and 100 F, to simulate the working UPA environment. A primary screening test for each material (virgin and conditioned) was dynamic mechanical analysis (DMA) in the stress relaxation mode, with the test data used to predict material performance for a 10-year use in space. Data showed that most of the candidate materials passed the compatibility testing, although a few significant changes in stress relaxation modulus were observed.
Neurolinguistic Programming Examined: Imagery, Sensory Mode, and Communication.
ERIC Educational Resources Information Center
Fromme, Donald K.; Daniell, Jennifer
1984-01-01
Tested Neurolinguistic Programming (NLP) assumptions by examining intercorrelations among response times of students (N=64) for extracting visual, auditory, and kinesthetic information from alphabetic images. Large positive intercorrelations were obtained, the only outcome not compatible with NLP. Good visualizers were significantly better in…
Spatial interactions during bimanual coordination patterns: the effect of directional compatibility.
Bogaerts, H; Swinnen, S P
2001-04-01
Whereas previous bimanual coordination research has predominantly focused on the constraining role of timing, the present study addressed the role of spatial (i.e., directional) constraints during the simultaneous production of equilateral triangles with both upper limbs. In addition to coordination modes in which mirror-image and isodirectional movements were performed (compatible patterns), new modes were tested in which the left limb lagged with respect to the right by one triangle side (non-compatible patterns). This resulted in the experimental manipulation of directional compatibility between the limbs. In addition, triangles with either horizontal or vertical orientations were to be drawn in order to assess the role of static images on movement production. Results supported the important role of directional constraints in bimanual coordination. Furthermore, triangles in vertical orientations (with a vertical symmetry axis, i.e., one apex pointing up) were drawn more successfully than those in horizontal orientations (with a horizontal symmetry axis, i.e., one apex pointing left or right), suggesting that the static aspects of a geometric form may affect movement dynamics. Finally, evidence suggested that cognitive processes related to integration of the submovements into a unified plan mediate the performance of new coordination patterns. The implications of the present finding for clinical populations are discussed
DOT National Transportation Integrated Search
2015-08-04
In 2012, the Navy requested spectrum certification for the shipboard AN/UPX-41(C) Digital Interrogator System, Software Version 5.5 with Mode 5. : Current operating conditions for the Navys AN/UPX-41(C) are the same as restrictions imposed on the ...
DOT National Transportation Integrated Search
2015-10-31
In 2012, the Navy requested spectrum certification for the shipboard AN/UPX-41(C) Digital Interrogator System, Software Version 5.5 with Mode 5. Current operating conditions for the Navys AN/UPX-41(C) are the same as restrictions imposed on the AN...
Electromagnetic Compatibility Testing of Implantable Neurostimulators Exposed to Metal Detectors
Seidman, Seth J; Kainz, Wolfgang; Casamento, Jon; Witters, Donald
2010-01-01
This paper presents results of electromagnetic compatibility (EMC) testing of three implantable neurostimulators exposed to the magnetic fields emitted from several walk-through and hand-held metal detectors. The motivation behind this testing comes from numerous adverse event reports involving active implantable medical devices (AIMDs) and security systems that have been received by the Food and Drug Administration (FDA). EMC testing was performed using three neurostimulators exposed to the emissions from 12 walk-through metal detectors (WTMDs) and 32 hand-held metal detectors (HHMDs). Emission measurements were performed on all HHMDs and WTMDs and summary data is presented. Results from the EMC testing indicate possible electromagnetic interference (EMI) between one of the neurostimulators and one WTMD and indicate that EMI between the three neurostimulators and HHMDs is unlikely. The results suggest that worst case situations for EMC testing are hard to predict and testing all major medical device modes and setting parameters are necessary to understand and characterize the EMC of AIMDs. PMID:20448818
NASA Technical Reports Server (NTRS)
Wingard, Charles D.
2003-01-01
In the International Space Station (ISS), astronauts will convert urine into potable water with the Urine Processor Assembly (UPA) by a distillation process. The urine is pre-treated, containing flush water and stabilizers. About 2.5% solids in the urine are concentrated up to 16% brine through distillation. Dynamic mechanical analysis (DMA) in the stress relaxation mode was primarily used to test 15 polymeric UPA materials for compatibility with the pre-treated and brine solutions. There were concerns that chromium trioxide (CrO3), a stabilizer not in the original pre-treat formulation for similar compatibility testing in 2000, could have an adverse effect on these polymers. DMA testing is partially complete for polymeric material samples immersed in the two solutions at room temperature for as long as 200 days. By comparing each material (conditioned and virgin), the stress relaxation modulus (E) was determined for short-term use and predicted for as long as a 10-year use in space. Such a delta E showed a decrease of as much as 79% for a Nylon material, but an increase as much as 454% for a polysulfone material, with increasing immersion time.
Mylonas, N; Damianou, C
2014-03-01
A prototype magnetic resonance imaging (MRI)-compatible positioning device that navigates a high intensity focused ultrasound (HIFU) transducer is presented. The positioning device has three user-controlled degrees of freedom that allow access to brain targets using a lateral coupling approach. The positioning device can be used for the treatment of brain cancer (thermal mode ultrasound) or ischemic stroke (mechanical mode ultrasound). The positioning device incorporates only MRI compatible materials such as piezoelectric motors, ABS plastic, brass screws, and brass rack and pinion. The robot has the ability to accurately move the transducer thus creating overlapping lesions in rabbit brain in vivo. The registration and repeatability of the system was evaluated using tissues in vitro and gel phantom and was also tested in vivo in the brain of a rabbit. A simple, cost effective, portable positioning device has been developed which can be used in virtually any clinical MRI scanner since it can be placed on the table of the MRI scanner. This system can be used to treat in the future patients with brain cancer and ischemic stroke. Copyright © 2013 John Wiley & Sons, Ltd.
Burgess, Edwin R; King, B H
2015-06-01
Various insecticides for the control of the house fly Musca domestica L. were tested for compatibility with a biological control agent, the pupal parasitoid Spalangia endius Walker. Bioassays used the mode in which each organism was expected to be harmed by the insecticides, a surface contact bioassay for S. endius and a feeding bioassay for M. domestica. A Pesticide Compatibility Index (PCI) was created that allows comparison of LC50 values when the mode of exposure to a pesticide differs. First LC50 values were converted into units of prescribed dosages (LPR=LC50-to-prescribed dosage ratio). This study used dosages from labels of granular baits. PCI is the ratio of LPRbiological control agent to LPRpest. For these PCI values, order of compatibility with S. endius was spinosad>thiamethoxam>inotefuran>methomyl>imidacloprid. That spinosad was better than imidacloprid or methomyl, both for parasitoid survival and for killing flies, is consistent with conclusions from the LC50 values. Permethrin and nitenpyram were also tested, but their PCIs were not calculated. Permethrin is prescribed as a contact insecticide against flies rather than being consumed as a bait, and nitenpyram has not been formulated as a fly insecticide. Compared with the other insecticides in terms of LC50 values, permethrin was moderately toxic to S. endius but one of the most toxic for M. domestica, whereas nitenpyram was least toxic for both S. endius and the flies. © The Authors 2015. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
NASA Technical Reports Server (NTRS)
Wilkes, R. L.; Kennedy, R. S.; Dunlap, W. P.; Lane, N. E.
1986-01-01
A need exists for an automated performance test system to study drugs, agents, treatments, and stresses of interest to the aviation, space, and environmental medical community. The purpose of this present study is to evaluate tests for inclusion in the NASA-sponsored Automated Performance Test System (APTS). Twenty-one subjects were tested over 10 replications with tests previously identified as good candidates for repeated-measure research. The tests were concurrently administered in paper-and-pencil and microcomputer modes. Performance scores for the two modes were compared. Data from trials 1 to 10 were examined for indications of test stability and reliability. Nine of the ten APT system tests achieved stability. Reliabilities were generally high. Cross-correlation of microbased tests with traditional paper-and-pencil versions revealed similarity of content within tests in the different modes, and implied at least three cognition and two motor factors. This protable, inexpensive, rugged, computerized battery of tests is recommended for use in repeated-measures studies of environmental and drug effects on performance. Identification of other tests compatible with microcomputer testing and potentially capable of tapping previously unidentified factors is recommended. Documentation of APTS sensitivity to environmental agents is available for more than a dozen facilities and is reported briefly. Continuation of such validation remains critical in establishing the efficacy of APTS tests.
NASA Technical Reports Server (NTRS)
Paul, Heather L.; Jennings, Mallory A.; Rivera, Fatonia L.; Martin, Devin
2011-01-01
NASA is designing a next generation Extravehicular Activity (EVA) Portable Life Support System (PLSS) for use in future surface exploration endeavors. To meet the new requirements for ventilation flow at nominal and buddy modes, a fan has been developed and tested. This paper summarizes the results of the performance and life cycle testing efforts conducted at the NASA Johnson Space Center. Additionally, oxygen compatibility assessment results from an evaluation conducted at White Sands Test Facility (WSTF) are provided, and lessons learned and future recommendations are outlined.
Yamaguchi, Motonori; Chen, Jing; Proctor, Robert W
2015-08-01
The Simon effect refers to the advantage of responding to spatially compatible stimuli. This effect can be eliminated or even reversed to favor spatially incompatible stimuli after participants practice a choice-reaction task with spatially incompatible mappings (e.g., pressing left and right keys to stimuli on the right and left, respectively). This transfer of incompatible spatial associations has been observed under conditions in which responses were made manually (e.g., keypresses, moving a joystick). The present study used vocal responses to reveal the primary determinants of the transfer effect, dissociating the influences of stimulus type, response mode, and their interaction (set-level compatibility). The results suggest that contextual match between the practice and transfer tasks with respect to stimulus type and response mode determined transfer of incompatible associations to the Simon task, and stimulus type determined the efficiency of acquiring new associations. However, there was little evidence that set-level compatibility plays any major role in either acquisition or transfer of spatial associations.
Hardware Demonstration: Radiated Emissions as a Function of Common Mode Current
NASA Technical Reports Server (NTRS)
Mc Closkey, John; Roberts, Jen
2016-01-01
This presentation describes the electromagnetic compatibility (EMC) tests performed on the Integrated Science Instrument Module (ISIM), the science payload of the James Webb Space Telescope (JWST), at NASAs Goddard Space Flight Center (GSFC) in August 2015. By its very nature of being an integrated payload, it could be treated as neither a unit level test nor an integrated spacecraft observatory test. Non-standard test criteria are described along with non-standard test methods that had to be developed in order to evaluate them. Results are presented to demonstrate that all test criteria were met in less than the time allocated.
Design of an MR-compatible fNIRS instrument
NASA Astrophysics Data System (ADS)
Emir, Uzay; Ademoglu, Ahmet; Ozturk, Cengizhan; Aydin, Kubilay; Demiralp, Tamer; Kurt, Adnan; Dincer, Alp; Akin, Ata
2005-04-01
Acquiring functional near infrared spectroscopy (fNIRS) and functional magnetic resonance-imaging (fMRI) data are usually done asynchronously. In order to correlate these two different modalities" data, measurements must be performed at the same time. In this study, we have designed a new MR compatible continuous wave intensity based fNIRS device to overcome this problem. For MR compatible fNIRS, we used two LEDs with wavelengths at 660 and 870 nm. There are four photodiodes for light detection. LEDs operated in a sequential multiplexing mode with adjustable "on" time for each LED. Emitted and diffused light was transferred to and from the tissue through 10 m long single mode plastic optical fibers (INDUSTRIAL FIBER OPTICS, INC.). By using fibers, we overcome MR compatibility problems that can be caused by semi-conductors on probe. This MR compatible fNIRS design can provide synchronous measurements with low cost.
Measurement technology of RF interference current in high current system
NASA Astrophysics Data System (ADS)
Zhao, Zhihua; Li, Jianxuan; Zhang, Xiangming; Zhang, Lei
2018-06-01
Current probe is a detection method commonly used in electromagnetic compatibility. With the development of power electronics technology, the power level of power conversion devices is constantly increasing, and the power current of the electric energy conversion device in the electromagnetic launch system can reach 10kA. Current probe conventionally used in EMC (electromagnetic compatibility) detection cannot meet the test requirements on high current system due to the magnetic saturation problem. The conventional high current sensor is also not suitable for the RF (Radio Frequency) interference current measurement in high current power device due to the high noise level in the output of active amplifier. In this paper, a passive flexible current probe based on Rogowski coil and matching resistance is proposed that can withstand high current and has low noise level, to solve the measurement problems of interference current in high current power converter. And both differential mode and common mode current detection can be easily carried out with the proposed probe because of the probe's flexible structure.
Nishimura, Ritsuko; Yoshizaki, Kazuhito; Kato, Kimiko; Hatta, Takeshi
2009-01-01
The present study examined the role of visual presentation mode (unilateral vs. bilateral visual fields) on attentional modulation. We examined whether or not the presentation mode affects the compatibility effect, using a paradigm involving two task-relevant letter arrays. Sixteen participants identified a target letter among task-relevant letters while ignoring either a compatible or incompatible distracter letter that was presented to both hemispheres. Two letters arrays were presented to visual fields, either unilaterally or bilaterally. Results indicated that the compatibility effect was greater in bilateral than in unilateral visual field conditions. Findings support the assumption that the two hemispheres have separate attentional resources.
APOLLO/SATURN (A/S) 201 - LAUNCH - CAPE
1966-02-26
A/S 201 was launched from the Kennedy Space Center Launch Complex 34 at 11:12 a.m., 02/26/1966. The instrumented Apollo Command and Service Module, and, a spacecraft Lunar Excursion Module Adapter, was successfully launched on the unmanned suborbital mission by the Saturn 1B to check spacecraft launch vehicle mechanical compatibility and to test the spacecraft heat shield in a high-velocity re-entry mode. CAPE KENNEDY, FL
DIII-D research to address key challenges for ITER and fusion energy
NASA Astrophysics Data System (ADS)
Buttery, R. J.; the DIII-D Team
2015-10-01
DIII-D has made significant advances in the scientific basis for fusion energy. The physics mechanism of resonant magnetic perturbation (RMP) edge localized mode (ELM) suppression is revealed as field penetration at the pedestal top, and reduced coil set operation was demonstrated. Disruption runaway electrons were effectively quenched by shattered pellets; runaway dissipation is explained by pitch angle scattering. Modest thermal quench radiation asymmetries are well described NIMROD modelling. With good pedestal regulation and error field correction, low torque ITER baselines have been demonstrated and shown to be compatible with an ITER test blanket module simulator. However performance and long wavelength turbulence degrade as low rotation and electron heating are approached. The alternative QH mode scenario is shown to be compatible with high Greenwald density fraction, with an edge harmonic oscillation demonstrating good impurity flushing. Discharge optimization guided by the EPED model has discovered a new super H-mode with doubled pedestal height. Lithium injection also led to wider, higher pedestals. On the path to steady state, 1 MA has been sustained fully noninductively with βN = 4 and RMP ELM suppression, while a peaked current profile scenario provides attractive options for ITER and a βN = 5 future reactor. Energetic particle transport is found to exhibit a critical gradient behaviour. Scenarios are shown to be compatible with radiative and snowflake divertor techniques. Physics studies reveal that the transition to H mode is locked in by a rise in ion diamagnetic flows. Intrinsic rotation in the plasma edge is demonstrated to arise from kinetic losses. New 3D magnetic sensors validate linear ideal MHD, but identify issues in nonlinear simulations. Detachment, characterized in 2D with sub-eV resolution, reveals a radiation shortfall in simulations. Future facility development targets burning plasma physics with torque free electron heating, the path to steady state with increased off axis currents, and a new divertor solution for fusion reactors.
DIII-D research to address key challenges for ITER and fusion energy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Buttery, Richard J.
DIII-D has made significant advances in the scientific basis for fusion energy. The physics mechanism of resonant magnetic perturbation (RMP) edge localized mode (ELM) suppression is revealed as field penetration at the pedestal top, and reduced coil set operation was demonstrated. Disruption runaway electrons were effectively quenched by shattered pellets; runaway dissipation is explained by pitch angle scattering. Modest thermal quench radiation asymmetries are well described NIMROD modeling. With good pedestal regulation and error field correction, low torque ITER baselines have been demonstrated and shown to be compatible with an ITER test blanket module simulator. However performance and long wavelengthmore » turbulence degrade as low rotation and electron heating are approached. The alternative QH mode scenario is shown to be compatible with high Greenwald density fraction, with an edge harmonic oscillation demonstrating good impurity flushing. Discharge optimization guided by the EPED model has discovered a new super H-mode with doubled pedestal height. Lithium injection also led to wider, higher pedestals. On the path to steady state, 1 MA has been sustained fully non inductively with β N = 4 and RMP ELM suppression, while a peaked current profile scenario provides attractive options for ITER and a β N = 5 future reactor. Energetic particle transport is found to exhibit a critical gradient behavior. Scenarios are shown to be compatible with radiative and snowflake diverter techniques. Physics studies reveal that the transition to H mode is locked in by a rise in ion diamagnetic flows. Intrinsic rotation in the plasma edge is demonstrated to arise from kinetic losses. New 3D magnetic sensors validate linear ideal MHD, but identify issues in nonlinear simulations. Detachment, characterized in 2D with sub-eV resolution, reveals a radiation shortfall in simulations. As a result, future facility development targets burning plasma physics with torque free electron heating, the path to steady state with increased off axis currents, and a new divertor solution for fusion reactors.« less
DIII-D research to address key challenges for ITER and fusion energy
Buttery, Richard J.
2015-07-29
DIII-D has made significant advances in the scientific basis for fusion energy. The physics mechanism of resonant magnetic perturbation (RMP) edge localized mode (ELM) suppression is revealed as field penetration at the pedestal top, and reduced coil set operation was demonstrated. Disruption runaway electrons were effectively quenched by shattered pellets; runaway dissipation is explained by pitch angle scattering. Modest thermal quench radiation asymmetries are well described NIMROD modeling. With good pedestal regulation and error field correction, low torque ITER baselines have been demonstrated and shown to be compatible with an ITER test blanket module simulator. However performance and long wavelengthmore » turbulence degrade as low rotation and electron heating are approached. The alternative QH mode scenario is shown to be compatible with high Greenwald density fraction, with an edge harmonic oscillation demonstrating good impurity flushing. Discharge optimization guided by the EPED model has discovered a new super H-mode with doubled pedestal height. Lithium injection also led to wider, higher pedestals. On the path to steady state, 1 MA has been sustained fully non inductively with β N = 4 and RMP ELM suppression, while a peaked current profile scenario provides attractive options for ITER and a β N = 5 future reactor. Energetic particle transport is found to exhibit a critical gradient behavior. Scenarios are shown to be compatible with radiative and snowflake diverter techniques. Physics studies reveal that the transition to H mode is locked in by a rise in ion diamagnetic flows. Intrinsic rotation in the plasma edge is demonstrated to arise from kinetic losses. New 3D magnetic sensors validate linear ideal MHD, but identify issues in nonlinear simulations. Detachment, characterized in 2D with sub-eV resolution, reveals a radiation shortfall in simulations. As a result, future facility development targets burning plasma physics with torque free electron heating, the path to steady state with increased off axis currents, and a new divertor solution for fusion reactors.« less
On-screen-display (OSD) menu detection for proper stereo content reproduction for 3D TV
NASA Astrophysics Data System (ADS)
Tolstaya, Ekaterina V.; Bucha, Victor V.; Rychagov, Michael N.
2011-03-01
Modern consumer 3D TV sets are able to show video content in two different modes: 2D and 3D. In 3D mode, stereo pair comes from external device such as Blue-ray player, satellite receivers etc. The stereo pair is split into left and right images that are shown one after another. The viewer sees different image for left and right eyes using shutter-glasses properly synchronized with a 3DTV. Besides, some devices that provide TV with a stereo content are able to display some additional information by imposing an overlay picture on video content, an On-Screen-Display (OSD) menu. Some OSDs are not always 3D compatible and lead to incorrect 3D reproduction. In this case, TV set must recognize the type of OSD, whether it is 3D compatible, and visualize it correctly by either switching off stereo mode, or continue demonstration of stereo content. We propose a new stable method for detection of 3D incompatible OSD menus on stereo content. Conventional OSD is a rectangular area with letters and pictograms. OSD menu can be of different transparency levels and colors. To be 3D compatible, an OSD is overlaid separately on both images of a stereo pair. The main problem in detecting OSD is to distinguish whether the color difference is due to OSD presence, or due to stereo parallax. We applied special techniques to find reliable image difference and additionally used a cue that usually OSD has very implicit geometrical features: straight parallel lines. The developed algorithm was tested on our video sequences database, with several types of OSD with different colors and transparency levels overlaid upon video content. Detection quality exceeded 99% of true answers.
Pitting intuitive and analytical thinking against each other: the case of transitivity.
Rusou, Zohar; Zakay, Dan; Usher, Marius
2013-06-01
Identifying which thinking mode, intuitive or analytical, yields better decisions has been a major subject of inquiry by decision-making researchers. Yet studies show contradictory results. One possibility is that the ambiguity is due to the variability in experimental conditions across studies. Our hypothesis is that decision quality depends critically on the level of compatibility between the thinking mode employed in the decision and the nature of the decision-making task. In two experiments, we pitted intuition and analytical thinking against each other on tasks that were either mainly intuitive or mainly analytical. Thinking modes, as well as task characteristics, were manipulated in a factorial design, with choice transitivity as the dependent measure. Results showed higher choice consistency (transitivity) when thinking mode and the characteristics of the decision task were compatible.
A bi-directional two-phase/two-phase heat exchanger
NASA Technical Reports Server (NTRS)
Ku, Jentung; Ottenstein, Laura
1993-01-01
This paper describes the design and test of a heat exchanger that transfers heat from one two-phase thermal loop to another with very small drops in temperature and pressure. The heat exchanger condenses the vapor in one loop while evaporating the liquid in the other without mixing of the condensing and evaporating fluids. The heat exchanger is bidirectional in that it can transfer heat in reverse, condensing on the normally evaporating side and vice versa. It is fully compatible with capillary pumped loops and mechanically pumped loops. Test results verified that performance of the heat exchanger met the design requirements. It demonstrated a heat transfer rate of 6800 watts in the normal mode of operation and 1000 watts in the reverse mode with temperature drops of less than 5 C between two thermal loops.
A new test machine for measuring friction and wear in controlled atmospheres to 1200 C
NASA Technical Reports Server (NTRS)
Sliney, Harold E.; Dellacorte, Christopher
1991-01-01
This paper describes a new high-temperature friction and wear test apparatus (tribometer). The tribometer can be used as a pin-on-disk or pin-on-ring configuration and is specially designed to measure the tribological properties of ceramics and high temperature metallic alloys from room temperature to 1200 C. Sliding mode can be selected to be either unidirectional at velocities up to 22 m/sec or oscillating at frequencies up to 4.6 Hz and amplitudes up to + or - 60 deg. The test atmosphere is established by a controlled flow rate of a purge gas. All components within the test chamber are compatible with oxidizing, inert or reducing gases.
Effect of Background Pressure on the Plasma Oscillation Characteristics of the HiVHAc Hall Thruster
NASA Technical Reports Server (NTRS)
Huang, Wensheng; Kamhawi, Hani; Lobbia, Robert B.; Brown, Daniel L.
2014-01-01
During a component compatibility test of the NASA HiVHAc Hall thruster, a high-speed camera and a set of high-speed Langmuir probes were implemented to study the effect of varying facility background pressure on thruster operation. The results show a rise in the oscillation frequency of the breathing mode with rising background pressure, which is hypothesized to be due to a shortening accelerationionization zone. An attempt is made to apply a simplified ingestion model to the data. The combined results are used to estimate the maximum acceptable background pressure for performance and wear testing.
A Computationally Efficient Visual Saliency Algorithm Suitable for an Analog CMOS Implementation.
D'Angelo, Robert; Wood, Richard; Lowry, Nathan; Freifeld, Geremy; Huang, Haiyao; Salthouse, Christopher D; Hollosi, Brent; Muresan, Matthew; Uy, Wes; Tran, Nhut; Chery, Armand; Poppe, Dorothy C; Sonkusale, Sameer
2018-06-27
Computer vision algorithms are often limited in their application by the large amount of data that must be processed. Mammalian vision systems mitigate this high bandwidth requirement by prioritizing certain regions of the visual field with neural circuits that select the most salient regions. This work introduces a novel and computationally efficient visual saliency algorithm for performing this neuromorphic attention-based data reduction. The proposed algorithm has the added advantage that it is compatible with an analog CMOS design while still achieving comparable performance to existing state-of-the-art saliency algorithms. This compatibility allows for direct integration with the analog-to-digital conversion circuitry present in CMOS image sensors. This integration leads to power savings in the converter by quantizing only the salient pixels. Further system-level power savings are gained by reducing the amount of data that must be transmitted and processed in the digital domain. The analog CMOS compatible formulation relies on a pulse width (i.e., time mode) encoding of the pixel data that is compatible with pulse-mode imagers and slope based converters often used in imager designs. This letter begins by discussing this time-mode encoding for implementing neuromorphic architectures. Next, the proposed algorithm is derived. Hardware-oriented optimizations and modifications to this algorithm are proposed and discussed. Next, a metric for quantifying saliency accuracy is proposed, and simulation results of this metric are presented. Finally, an analog synthesis approach for a time-mode architecture is outlined, and postsynthesis transistor-level simulations that demonstrate functionality of an implementation in a modern CMOS process are discussed.
An Approach to Average Modeling and Simulation of Switch-Mode Systems
ERIC Educational Resources Information Center
Abramovitz, A.
2011-01-01
This paper suggests a pedagogical approach to teaching the subject of average modeling of PWM switch-mode power electronics systems through simulation by general-purpose electronic circuit simulators. The paper discusses the derivation of PSPICE/ORCAD-compatible average models of the switch-mode power stages, their software implementation, and…
Radiation-Hard SpaceWire/Gigabit Ethernet-Compatible Transponder
NASA Technical Reports Server (NTRS)
Katzman, Vladimir
2012-01-01
A radiation-hard transponder was developed utilizing submicron/nanotechnology from IBM. The device consumes low power and has a low fabrication cost. This device utilizes a Plug-and-Play concept, and can be integrated into intra-satellite networks, supporting SpaceWire and Gigabit Ethernet I/O. A space-qualified, 100-pin package also was developed, allowing space-qualified (class K) transponders to be delivered within a six-month time frame. The novel, optical, radiation-tolerant transponder was implemented as a standalone board, containing the transponder ASIC (application specific integrated circuit) and optical module, with an FPGA (field-programmable gate array) friendly parallel interface. It features improved radiation tolerance; high-data-rate, low-power consumption; and advanced functionality. The transponder utilizes a patented current mode logic library of radiation-hardened-by-architecture cells. The transponder was developed, fabricated, and radhard tested up to 1 MRad. It was fabricated using 90-nm CMOS (complementary metal oxide semiconductor) 9 SF process from IBM, and incorporates full BIT circuitry, allowing a loop back test. The low-speed parallel LVCMOS (lowvoltage complementary metal oxide semiconductor) bus is compatible with Actel FPGA. The output LVDS (low-voltage differential signaling) interface operates up to 1.5 Gb/s. Built-in CDR (clock-data recovery) circuitry provides robust synchronization and incorporates two alarm signals such as synch loss and signal loss. The ultra-linear peak detector scheme allows on-line control of the amplitude of the input signal. Power consumption is less than 300 mW. The developed transponder with a 1.25 Gb/s serial data rate incorporates a 10-to-1 serializer with an internal clock multiplication unit and a 10-1 deserializer with internal clock and data recovery block, which can operate with 8B10B encoded signals. Three loop-back test modes are provided to facilitate the built-in-test functionality. The design is based on a proprietary library of differential current switching logic cells implemented in the standard 90-nm CMOS 9SF technology from IBM. The proprietary low-power LVDS physical interface is fully compatible with the SpaceWire standard, and can be directly connected to the SFP MSA (small form factor pluggable Multiple Source Agreement) optical transponder. The low-speed parallel interfaces are fully compatible with the standard 1.8 V CMOS input/output devices. The utilized proprietary annular CMOS layout structures provide TID tolerance above 1.2 MRad. The complete chip consumes less than 150 mW of power from a single 1.8-V positive supply source.
Design of the central region in the Warsaw K-160 cyclotron
NASA Astrophysics Data System (ADS)
Toprek, Dragan; Sura, Josef; Choinski, Jaroslav; Czosnyka, Tomas
2001-08-01
This paper describes the design of the central region for h=2 and 3 modes of acceleration in the Warsaw K-160 cyclotron. The central region is unique and compatible with the two above-mentioned harmonic modes of operation. Only one spiral type inflector will be used. The electric field distribution in the inflector and in the four acceleration gaps has been numerically calculated from an electric potential map produced by the program RELAX3D. The geometry of the central region has been tested with the computations of orbits carried out by means of the computer code CYCLONE. The optical properties of the spiral inflector and the central region were studied by using the programs CASINO and CYCLONE, respectively.
NASA Technical Reports Server (NTRS)
1975-01-01
The economic and technical feasibility is assessed of employing a pallet-only mode for conducting Atmospheric Magnetospheric Plasmas-in-Space experiments. A baseline design incorporating the experiment and instrument descriptions is developed. The prime instruments are packaged into four pallets in a physical and functional manner compatible with the Space Transportation System capabilities and/or constraints and an orbiter seven-day mission timeline. Operational compatibility is verified between the orbiter/payload and supporting facilities. The development status and the schedule requirements applicable to the Atmospheric Science Facility mission are identified. Conclusions and recommendations are presented and discussed.
Aslam, Muhammad Zubair; Jeoti, Varun; Karuppanan, Saravanan; Malik, Aamir Farooq; Iqbal, Asif
2018-05-24
A Finite Element Method (FEM) simulation study is conducted, aiming to scrutinize the sensitivity of Sezawa wave mode in a multilayer AlN/SiO₂/Si Surface Acoustic Wave (SAW) sensor to low concentrations of Volatile Organic Compounds (VOCs), that is, trichloromethane, trichloroethylene, carbon tetrachloride and tetrachloroethene. A Complimentary Metal-Oxide Semiconductor (CMOS) compatible AlN/SiO₂/Si based multilayer SAW resonator structure is taken into account for this purpose. In this study, first, the influence of AlN and SiO₂ layers’ thicknesses over phase velocities and electromechanical coupling coefficients ( k ²) of two SAW modes (i.e., Rayleigh and Sezawa) is analyzed and the optimal thicknesses of AlN and SiO₂ layers are opted for best propagation characteristics. Next, the study is further extended to analyze the mass loading effect on resonance frequencies of SAW modes by coating a thin Polyisobutylene (PIB) polymer film over the AlN surface. Finally, the sensitivity of the two SAW modes is examined for VOCs. This study concluded that the sensitivity of Sezawa wave mode for 1 ppm of selected volatile organic gases is twice that of the Rayleigh wave mode.
A new test machine for measuring friction and wear in controlled atmospheres to 1200 C
NASA Technical Reports Server (NTRS)
Sliney, Harold E.; Dellacorte, Christopher
1989-01-01
This paper describes a new high temperature friction and wear test apparatus (tribometer) at NASA Lewis Research Center, Cleveland, Ohio. The tribometer can be used as a pin-on-disk or pin-on-ring configuration and is specially designed to measure the tribological properties of ceramics and high temperature metallic alloys from room temperature to 1200 C. Sliding mode can be selected to be either unidirectional at velocities up to 22 m/sec or oscillating at frequencies up 4.5 Hz and amplitudes up to + or - 60 deg. The test atmosphere is established by a controlled flow rate of a purge gas. All components within the test chamber are compatible with oxidizing, inert, or reducing gases.
NASA Astrophysics Data System (ADS)
Abbasi, R. U.; Abe, M.; Abu-Zayyad, T.; Allen, M.; Azuma, R.; Barcikowski, E.; Belz, J. W.; Bergman, D. R.; Blake, S. A.; Cady, R.; Cheon, B. G.; Chiba, J.; Chikawa, M.; di Matteo, A.; Fujii, T.; Fujita, K.; Fukushima, M.; Furlich, G.; Goto, T.; Hanlon, W.; Hayashi, M.; Hayashi, Y.; Hayashida, N.; Hibino, K.; Honda, K.; Ikeda, D.; Inoue, N.; Ishii, T.; Ishimori, R.; Ito, H.; Ivanov, D.; Jeong, H. M.; Jeong, S. M.; Jui, C. C. H.; Kadota, K.; Kakimoto, F.; Kalashev, O.; Kasahara, K.; Kawai, H.; Kawakami, S.; Kawana, S.; Kawata, K.; Kido, E.; Kim, H. B.; Kim, J. H.; Kim, J. H.; Kishigami, S.; Kitamura, S.; Kitamura, Y.; Kuzmin, V.; Kuznetsov, M.; Kwon, Y. J.; Lee, K. H.; Lubsandorzhiev, B.; Lundquist, J. P.; Machida, K.; Martens, K.; Matsuyama, T.; Matthews, J. N.; Mayta, R.; Minamino, M.; Mukai, K.; Myers, I.; Nagasawa, K.; Nagataki, S.; Nakamura, R.; Nakamura, T.; Nonaka, T.; Oda, H.; Ogio, S.; Ogura, J.; Ohnishi, M.; Ohoka, H.; Okuda, T.; Omura, Y.; Ono, M.; Onogi, R.; Oshima, A.; Ozawa, S.; Park, I. H.; Pshirkov, M. S.; Rodriguez, D. C.; Rubtsov, G.; Ryu, D.; Sagawa, H.; Sahara, R.; Saito, K.; Saito, Y.; Sakaki, N.; Sakurai, N.; Scott, L. M.; Seki, T.; Sekino, K.; Shah, P. D.; Shibata, F.; Shibata, T.; Shimodaira, H.; Shin, B. K.; Shin, H. S.; Smith, J. D.; Sokolsky, P.; Stokes, B. T.; Stratton, S. R.; Stroman, T. A.; Suzawa, T.; Takagi, Y.; Takahashi, Y.; Takamura, M.; Takeda, M.; Takeishi, R.; Taketa, A.; Takita, M.; Tameda, Y.; Tanaka, H.; Tanaka, K.; Tanaka, M.; Thomas, S. B.; Thomson, G. B.; Tinyakov, P.; Tkachev, I.; Tokuno, H.; Tomida, T.; Troitsky, S.; Tsunesada, Y.; Tsutsumi, K.; Uchihori, Y.; Udo, S.; Urban, F.; Wong, T.; Yamamoto, M.; Yamane, R.; Yamaoka, H.; Yamazaki, K.; Yang, J.; Yashiro, K.; Yoneda, Y.; Yoshida, S.; Yoshii, H.; Zhezher, Y.; Zundel, Z.; Telescope Array Collaboration
2018-05-01
The Telescope Array (TA) observatory utilizes fluorescence detectors and surface detectors (SDs) to observe air showers produced by ultra high energy cosmic rays in Earth’s atmosphere. Cosmic-ray events observed in this way are termed hybrid data. The depth of air shower maximum is related to the mass of the primary particle that generates the shower. This paper reports on shower maxima data collected over 8.5 yr using the Black Rock Mesa and Long Ridge fluorescence detectors in conjunction with the array of SDs. We compare the means and standard deviations of the observed {X}\\max distributions with Monte Carlo {X}\\max distributions of unmixed protons, helium, nitrogen, and iron, all generated using the QGSJet II-04 hadronic model. We also perform an unbinned maximum likelihood test of the observed data, which is subjected to variable systematic shifting of the data {X}\\max distributions to allow us to test the full distributions, and compare them to the Monte Carlo to see which elements are not compatible with the observed data. For all energy bins, QGSJet II-04 protons are found to be compatible with TA hybrid data at the 95% confidence level after some systematic {X}\\max shifting of the data. Three other QGSJet II-04 elements are found to be compatible using the same test procedure in an energy range limited to the highest energies where data statistics are sparse.
Compatibility of the Radio Frequency Mass Gauge with Graphite-Epoxy Composite Tanks
NASA Technical Reports Server (NTRS)
Zimmerli, G. A.; Mueller, C. H.
2015-01-01
The radio frequency mass gauge (RFMG) is a low-gravity propellant quantity gauge being developed at NASA for possible use in long-duration space missions utilizing cryogenic propellants. As part of the RFMG technology development process, we evaluated the compatibility of the RFMG with a graphite-epoxy composite material used to construct propellant tanks. The key material property that can affect compatibility with the RFMG is the electrical conductivity. Using samples of 8552/IM7 graphite-epoxy composite, we characterized the resistivity and reflectivity over a range of frequencies. An RF impedance analyzer was used to characterize the out-of-plane electrical properties (along the sample thickness) in the frequency range 10 to 1800 MHZ. The resistivity value at 500 MHz was 4.8 ohm-cm. Microwave waveguide measurements of samples in the range 1.7 - 2.6 GHz, performed by inserting the samples into a WR-430 waveguide, showed reflectivity values above 98%. Together, these results suggested that a tank constructed from graphite/epoxy composite would produce good quality electromagnetic tank modes, which is needed for the RFMG. This was verified by room-temperature measurements of the electromagnetic modes of a 2.4 m diameter tank constructed by Boeing from similar graphite-epoxy composite material. The quality factor Q of the tank electromagnetic modes, measured via RF reflection measurements from an antenna mounted in the tank, was typically in the range 400 less than Q less than 3000. The good quality modes observed in the tank indicate that the RFMG is compatible with graphite-epoxy tanks, and thus the RFMG could be used as a low-gravity propellant quantity gauge in such tanks filled with cryogenic propellants.
Compatibility of the Radio Frequency Mass Gauge with Composite Tanks
NASA Technical Reports Server (NTRS)
Zimmerli, Greg; Mueller, Carl
2015-01-01
The radio frequency mass gauge (RFMG) is a low-gravity propellant quantity gauge being developed at NASA for possible use in long-duration space missions utilizing cryogenic propellants. As part of the RFMG technology development process, we evaluated the compatibility of the RFMG with a graphite-epoxy composite material used to construct propellant tanks. The key material property that can affect compatibility with the RFMG is the electrical conductivity. Using samples of 8552IM7 graphite-epoxy composite, we characterized the resistivity and reflectivity over a range of frequencies. An RF impedance analyzer was used to characterize the out-of-plane electrical properties (along the sample thickness) in the frequency range 10 to 1800 MHZ. The resistivity value at 500 MHz was 4.8 ohm-cm. Microwave waveguide measurements of samples in the range 1.7 2.6 GHz, performed by inserting the samples into a WR-430 waveguide, showed reflectivity values above 98. Together, these results suggested that a tank constructed from graphite-epoxy composite would produce good quality electromagnetic tank modes, which is needed for the RFMG. This was verified by room-temperature measurements of the electromagnetic modes of a 2.4 m diameter tank constructed by Boeing from similar graphite-epoxy composite material. The quality factor Q of the tank electromagnetic modes, measured via RF reflection measurements from an antenna mounted in the tank, was typically in the range 400 Q 3000. The good quality modes observed in the tank indicate that the RFMG is compatible with graphite-epoxy tanks, and thus the RFMG could be used as a low-gravity propellant quantity gauge in such tanks filled with cryogenic propellants.
Development and Validation of a Mobile Device-based External Ventricular Drain Simulator.
Morone, Peter J; Bekelis, Kimon; Root, Brandon K; Singer, Robert J
2017-10-01
Multiple external ventricular drain (EVD) simulators have been created, yet their cost, bulky size, and nonreusable components limit their accessibility to residency programs. To create and validate an animated EVD simulator that is accessible on a mobile device. We developed a mobile-based EVD simulator that is compatible with iOS (Apple Inc., Cupertino, California) and Android-based devices (Google, Mountain View, California) and can be downloaded from the Apple App and Google Play Store. Our simulator consists of a learn mode, which teaches users the procedure, and a test mode, which assesses users' procedural knowledge. Twenty-eight participants, who were divided into expert and novice categories, completed the simulator in test mode and answered a postmodule survey. This was graded using a 5-point Likert scale, with 5 representing the highest score. Using the survey results, we assessed the module's face and content validity, whereas construct validity was evaluated by comparing the expert and novice test scores. Participants rated individual survey questions pertaining to face and content validity a median score of 4 out of 5. When comparing test scores, generated by the participants completing the test mode, the experts scored higher than the novices (mean, 71.5; 95% confidence interval, 69.2 to 73.8 vs mean, 48; 95% confidence interval, 44.2 to 51.6; P < .001). We created a mobile-based EVD simulator that is inexpensive, reusable, and accessible. Our results demonstrate that this simulator is face, content, and construct valid. Copyright © 2017 by the Congress of Neurological Surgeons
A multifunctional PVDF-based tactile sensor for minimally invasive surgery
NASA Astrophysics Data System (ADS)
Sokhanvar, S.; Packirisamy, M.; Dargahi, J.
2007-08-01
In this paper a multifunctional tactile sensor system using PVDF (polyvinylidene fluoride), is proposed, designed, analyzed, tested and validated. The working principle of the sensor is in such a way that it can be used in combination with almost any end-effectors. However, the sensor is particularly designed to be integrated with minimally invasive surgery (MIS) tools. In addition, the structural and transduction materials are selected to be compatible with micro-electro-mechanical systems (MEMS) technology, so that miniaturization would be possible. The corrugated shape of the sensor ensures the safe tissue grasping and compatibility with the traditional tooth-like end effectors of MIS tools. A unit of this sensor comprised of a base, a flexible beam and three PVDF sensing elements. Two PVDF sensing elements sandwiched at the end supports work in thickness mode to measure the magnitude and position of applied load. The third PVDF sensing element is attached to the beam and it works in the extensional mode to measure the softness of the contact object. The proposed sensor is modeled both analytically and numerically and a series of simulations are performed in order to estimate the characteristics of the sensor in measuring the magnitude and position of a point load, distributed load, and also the softness of the contact object. Furthermore, in order to validate the theoretical results, the prototyped sensor was tested and the results are compared. The results are very promising and proving the capability of the sensor for haptic sensing.
Surfing gravitational waves: can bigravity survive growing tensor modes?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Amendola, Luca; Könnig, Frank; Martinelli, Matteo
The theory of bigravity offers one of the simplest possibilities to describe a massive graviton while having self-accelerating cosmological solutions without a cosmological constant. However, it has been shown recently that bigravity is affected by early-time fast growing modes on the tensor sector. Here we argue that we can only trust the linear analysis up to when perturbations are in the linear regime and use a cut-off to stop the growing of the metric perturbations. This analysis, although more consistent, still leads to growing tensor modes that are unacceptably large for the theory to be compatible with measurements of themore » cosmic microwave background (CMB), both in temperature and polarization spectra. In order to suppress the growing modes and make the model compatible with CMB spectra, we find it necessary to either fine-tune the initial conditions, modify the theory or set the cut-off for the tensor perturbations of the second metric much lower than unity. Initial conditions such that the growing mode is sufficiently suppresed can be achieved in scenarios in which inflation ends at the GeV scale.« less
A Model of the Pulsating Extremely Low-mass White Dwarf Precursor WASP 0247-25B
NASA Astrophysics Data System (ADS)
Istrate, A. G.; Fontaine, G.; Heuser, C.
2017-10-01
We present an analysis of the evolutionary and pulsation properties of the extremely low-mass white dwarf precursor (B) component of the double-lined eclipsing system WASP 0247-25. Given that the fundamental parameters of that star have been obtained previously at a unique level of precision, WASP 0247-25B represents the ideal case for testing evolutionary models of this newly found category of pulsators. Taking into account the known constraints on the mass, orbital period, effective temperature, surface gravity, and atmospheric composition, we present a model that is compatible with these constraints and show pulsation modes that have periods very close to the observed values. Importantly, these modes are predicted to be excited. Although the overall consistency remains perfectible, the observable properties of WASP 0247-25B are closely reproduced. A key ingredient of our binary evolutionary models is represented by rotational mixing as the main competitor against gravitational settling. Depending on assumptions made about the values of the degree index ℓ for the observed pulsation modes, we found three possible seismic solutions. We discuss two tests, rotational splitting and multicolor photometry, that should readily identify the modes and discriminate between these solutions. However, this will require improved temporal resolution and higher S/N observations, which are currently unavailable.
NASA Astrophysics Data System (ADS)
Russell, John L.; Campbell, John L.; Boyd, Nicholas I.; Dias, Johnny F.
2018-02-01
The newly developed GUMAP software creates element maps from OMDAQ list mode files, displays these maps individually or collectively, and facilitates on-screen definitions of specified regions from which a PIXE spectrum can be built. These include a free-hand region defined by moving the cursor. The regional charge is entered automatically into the spectrum file in a new GUPIXWIN-compatible format, enabling a GUPIXWIN analysis of the spectrum. The code defaults to the OMDAQ dead time treatment but also facilitates two other methods for dead time correction in sample regions with count rates different from the average.
Konietschke, Frank; Libiger, Ondrej; Hothorn, Ludwig A
2012-01-01
Statistical association between a single nucleotide polymorphism (SNP) genotype and a quantitative trait in genome-wide association studies is usually assessed using a linear regression model, or, in the case of non-normally distributed trait values, using the Kruskal-Wallis test. While linear regression models assume an additive mode of inheritance via equi-distant genotype scores, Kruskal-Wallis test merely tests global differences in trait values associated with the three genotype groups. Both approaches thus exhibit suboptimal power when the underlying inheritance mode is dominant or recessive. Furthermore, these tests do not perform well in the common situations when only a few trait values are available in a rare genotype category (disbalance), or when the values associated with the three genotype categories exhibit unequal variance (variance heterogeneity). We propose a maximum test based on Marcus-type multiple contrast test for relative effect sizes. This test allows model-specific testing of either dominant, additive or recessive mode of inheritance, and it is robust against variance heterogeneity. We show how to obtain mode-specific simultaneous confidence intervals for the relative effect sizes to aid in interpreting the biological relevance of the results. Further, we discuss the use of a related all-pairwise comparisons contrast test with range preserving confidence intervals as an alternative to Kruskal-Wallis heterogeneity test. We applied the proposed maximum test to the Bogalusa Heart Study dataset, and gained a remarkable increase in the power to detect association, particularly for rare genotypes. Our simulation study also demonstrated that the proposed non-parametric tests control family-wise error rate in the presence of non-normality and variance heterogeneity contrary to the standard parametric approaches. We provide a publicly available R library nparcomp that can be used to estimate simultaneous confidence intervals or compatible multiplicity-adjusted p-values associated with the proposed maximum test.
Space Power Facility-Capabilities for Space Environmental Testing Within a Single Facility
NASA Technical Reports Server (NTRS)
Sorge, Richard N.
2013-01-01
The purpose of this paper is to describe the current and near-term environmental test capabilities of the NASA Glenn Research Center's Space Power Facility (SPF) located at Sandusky, Ohio. The paper will present current and near-term capabilities for conducting electromagnetic interference and compatibility testing, base-shake sinusoidal vibration testing, reverberant acoustic testing, and thermal-vacuum testing. The paper will also present modes of transportation, handling, ambient environments, and operations within the facility to conduct those tests. The SPF is in the midst of completing and activating new or refurbished capabilities which, when completed, will provide the ability to conduct most or all required full-scale end-assembly space simulation tests at a single test location. It is envisioned that the capabilities will allow a customer to perform a wide range of space simulation tests in one facility at reasonable cost.
Air-to-air radar flight testing
NASA Astrophysics Data System (ADS)
Scott, Randall E.
1988-06-01
This volume in the AGARD Flight Test Techniques Series describes flight test techniques, flight test instrumentation, ground simulation, data reduction and analysis methods used to determine the performance characteristics of a modern air-to-air (a/a) radar system. Following a general coverage of specification requirements, test plans, support requirements, development and operational testing, and management information systems, the report goes into more detailed flight test techniques covering a/a radar capabilities of: detection, manual acquisition, automatic acquisition, tracking a single target, and detection and tracking of multiple targets. There follows a section on additional flight test considerations such as electromagnetic compatibility, electronic countermeasures, displays and controls, degraded and backup modes, radome effects, environmental considerations, and use of testbeds. Other sections cover ground simulation, flight test instrumentation, and data reduction and analysis. The final sections deal with reporting and a discussion of considerations for the future and how they may affect radar flight testing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ding, Xuran, E-mail: xheron9413@163.com; Lou, Wenzhong, E-mail: louwz@bit.edu.cn, E-mail: fengyue@bit.edu.cn; Feng, Yue, E-mail: louwz@bit.edu.cn, E-mail: fengyue@bit.edu.cn
A controllable IC-compatible thin-film fuse was developed that had Al/SiO{sub 2} thin-film stacks on a silicon substrate. The micro fuse has both a traditional mode and a controllable mode when applied as a fuse. It blows at 800 mA and 913.8 mV in the traditional mode. In the controllable mode, it blows within 400 ns at 10 V. It can be used for small electronic elements as well as electropyrotechnic initiators to improve the no-firing current.
Design and Testing of a Ground-based System for Phase Stabilized Standard Frequency Transmission
NASA Astrophysics Data System (ADS)
Wang, J. Q.; Jiang, Y. C.; Gou, W.; Yu, L. F.; Liu, Q. H.; Fan, Q. Y.; Lou, F. X.; Lao, B. Q.
2014-09-01
In this paper, a 1.5 GHz phase stabilized frequency transmission system is described. Compatible with the coaxial cable and optical fiber transmission media, the system has both the capabilities of real-time and post phase compensation. The phase stabilizing principle of the equipment is analyzed, and its performance is evaluated. Under the test environment, the results of the prototype system based on a coaxial cable show that the real-time compensation mode can improve the phase stabilities by more than 112 times in comparison with the uncompensated cables. The frequency stabilities are also improved significantly with a 7-second integration time, and one order-of-magnitude improvement is achieved after 60 seconds. The post compensation mode can improve phase fluctuations by 40 times. The frequency stabilities can be improved significantly after 2.5-second integration, while a 10-fold enhancement is achieved after 40 seconds. With longer integration time, both real-time and post compensation modes can improve the frequency stabilities by more than 1.5 orders of magnitude. The proposed equipment can effectively reduce slowly stretching effects due to the factors such as the temperature coefficient variations of the transmission medium and mechanical disturbances.
Impact of pulse duration on Ho:YAG laser lithotripsy: fragmentation and dusting performance.
Bader, Markus J; Pongratz, Thomas; Khoder, Wael; Stief, Christian G; Herrmann, Thomas; Nagele, Udo; Sroka, Ronald
2015-04-01
In vitro investigations of Ho:YAG laser-induced stone fragmentation were performed to identify potential impacts of different pulse durations on stone fragmentation characteristics. A Ho:YAG laser system (Swiss LaserClast, EMS S.A., Nyon, Switzerland) with selectable long or short pulse mode was tested with regard to its fragmentation and laser hardware compatibility properties. The pulse duration is depending on the specific laser parameters. Fragmentation tests (hand-held, hands-free, single-pulse-induced crater) on artificial BEGO stones were performed under reproducible experimental conditions (fibre sizes: 365 and 200 µm; laser settings: 10 W through combinations of 0.5, 1, 2 J/pulse and 20, 10, 5 Hz, respectively). Differences in fragmentation rates between the two pulse duration regimes were detected with statistical significance for defined settings. Hand-held and motivated Ho:YAG laser-assisted fragmentation of BEGO stones showed no significant difference between short pulse mode and long pulse mode, neither in fragmentation rates nor in number of fragments and fragment sizes. Similarly, the results of the hands-free fragmentation tests (with and without anti-repulsion device) showed no statistical differences between long pulse and short pulse modes. The study showed that fragmentation rates for long and short pulse durations at identical power settings remain at a comparable level. Longer holmium laser pulse duration reduces stone pushback. Therefore, longer laser pulses may result in better clinical outcome of laser lithotripsy and more convenient handling during clinical use without compromising fragmentation effectiveness.
NASA Astrophysics Data System (ADS)
Moreira, Roberto L.; Lobo, Ricardo P. S. M.; Ramos, Sérgio L. L. M.; Sebastian, Mailadil T.; Matinaga, Franklin M.; Righi, Ariete; Dias, Anderson
2018-05-01
The low-temperature vibrational properties of B a2ZnTe O6 double-perovskite ceramics obtained by the solid-state route were investigated by Raman scattering and Fourier-transform infrared reflectivity. We found that this material undergoes a reversible ferroelastic phase transition at around 140 K, well compatible with a recently proposed rhombohedral-to-monoclinic structural change that would occur below 165 K. Complementary calorimetric measurements showed that the phase transition has a first-order character, with an entropy jump compatible with a displacive mechanism. The vibrational spectra show clearly the splitting of the doubly degenerate E modes into nondegenerate representations of the low-symmetry phase. In particular, the lowest-frequency Raman mode presents soft-mode behavior and splits below the critical temperature, confirming the in-plane ferroelastic deformation in the low-temperature phase.
[Magnetic resonance compatibility research for coronary mental stents].
Wang, Ying; Liu, Li; Wang, Shuo; Shang, Ruyao; Wang, Chunren
2015-01-01
The objective of this article is to research magnetic resonance compatibility for coronary mental stents, and to evaluate the magnetic resonance compatibility based on laboratory testing results. Coronary stents magnetic resonance compatibility test includes magnetically induced displacement force test, magnetically induced torque test, radio frequency induced heating and evaluation of MR image. By magnetic displacement force and torque values, temperature, and image distortion values to determine metal coronary stent demagnetization effect. The methods can be applied to test magnetic resonance compatibility for coronary mental stents and evaluate its demagnetization effect.
In situ 3D nanoprinting of free-form coupling elements for hybrid photonic integration
NASA Astrophysics Data System (ADS)
Dietrich, P.-I.; Blaicher, M.; Reuter, I.; Billah, M.; Hoose, T.; Hofmann, A.; Caer, C.; Dangel, R.; Offrein, B.; Troppenz, U.; Moehrle, M.; Freude, W.; Koos, C.
2018-04-01
Hybrid photonic integration combines complementary advantages of different material platforms, offering superior performance and flexibility compared with monolithic approaches. This applies in particular to multi-chip concepts, where components can be individually optimized and tested. The assembly of such systems, however, requires expensive high-precision alignment and adaptation of optical mode profiles. We show that these challenges can be overcome by in situ printing of facet-attached beam-shaping elements. Our approach allows precise adaptation of vastly dissimilar mode profiles and permits alignment tolerances compatible with cost-efficient passive assembly techniques. We demonstrate a selection of beam-shaping elements at chip and fibre facets, achieving coupling efficiencies of up to 88% between edge-emitting lasers and single-mode fibres. We also realize printed free-form mirrors that simultaneously adapt beam shape and propagation direction, and we explore multi-lens systems for beam expansion. The concept paves the way to automated assembly of photonic multi-chip systems with unprecedented performance and versatility.
A Numerical Theory for Impedance Education in Three-Dimensional Normal Incidence Tubes
NASA Technical Reports Server (NTRS)
Watson, Willie R.; Jones, Michael G.
2016-01-01
A method for educing the locally-reacting acoustic impedance of a test sample mounted in a 3-D normal incidence impedance tube is presented and validated. The unique feature of the method is that the excitation frequency (or duct geometry) may be such that high-order duct modes may exist. The method educes the impedance, iteratively, by minimizing an objective function consisting of the difference between the measured and numerically computed acoustic pressure at preselected measurement points in the duct. The method is validated on planar and high-order mode sources with data synthesized from exact mode theory. These data are then subjected to random jitter to simulate the effects of measurement uncertainties on the educed impedance spectrum. The primary conclusions of the study are 1) Without random jitter the method is in excellent agreement with that for known impedance samples, and 2) Random jitter that is compatible to that found in a typical experiment has minimal impact on the accuracy of the educed impedance.
Evans, T E; Moyer, R A; Thomas, P R; Watkins, J G; Osborne, T H; Boedo, J A; Doyle, E J; Fenstermacher, M E; Finken, K H; Groebner, R J; Groth, M; Harris, J H; La Haye, R J; Lasnier, C J; Masuzaki, S; Ohyabu, N; Pretty, D G; Rhodes, T L; Reimerdes, H; Rudakov, D L; Schaffer, M J; Wang, G; Zeng, L
2004-06-11
A stochastic magnetic boundary, produced by an applied edge resonant magnetic perturbation, is used to suppress most large edge-localized modes (ELMs) in high confinement (H-mode) plasmas. The resulting H mode displays rapid, small oscillations with a bursty character modulated by a coherent 130 Hz envelope. The H mode transport barrier and core confinement are unaffected by the stochastic boundary, despite a threefold drop in the toroidal rotation. These results demonstrate that stochastic boundaries are compatible with H modes and may be attractive for ELM control in next-step fusion tokamaks.
A Model of the Pulsating Extremely Low-mass White Dwarf Precursor WASP 0247–25B
DOE Office of Scientific and Technical Information (OSTI.GOV)
Istrate, A. G.; Fontaine, G.; Heuser, C., E-mail: istrate@uwm.edu
We present an analysis of the evolutionary and pulsation properties of the extremely low-mass white dwarf precursor (B) component of the double-lined eclipsing system WASP 0247−25. Given that the fundamental parameters of that star have been obtained previously at a unique level of precision, WASP 0247−25B represents the ideal case for testing evolutionary models of this newly found category of pulsators. Taking into account the known constraints on the mass, orbital period, effective temperature, surface gravity, and atmospheric composition, we present a model that is compatible with these constraints and show pulsation modes that have periods very close to themore » observed values. Importantly, these modes are predicted to be excited. Although the overall consistency remains perfectible, the observable properties of WASP 0247−25B are closely reproduced. A key ingredient of our binary evolutionary models is represented by rotational mixing as the main competitor against gravitational settling. Depending on assumptions made about the values of the degree index ℓ for the observed pulsation modes, we found three possible seismic solutions. We discuss two tests, rotational splitting and multicolor photometry, that should readily identify the modes and discriminate between these solutions. However, this will require improved temporal resolution and higher S/N observations, which are currently unavailable.« less
Wang, Qing; Long, Yao; Yao, Lin; Xu, Li; Shi, Zhi-Guo; Xu, Lanying
2016-01-01
A mixed-mode chromatographic stationary phase, C18-DTT (dithiothreitol) silica (SiO2) was prepared through "thiol-ene" click chemistry. The obtained material was characterized by fourier transform infrared spectroscope, nitrogen adsorption analysis and contact angle analysis. Chromatographic performance of the C18-DTT was systemically evaluated by studying the effect of acetonitrile content, pH, buffer concentration of the mobile phase and column temperature. It was demonstrated that the novel stationary phase possessed reversed phase liquid chromatography (RPLC)/hydrophilic interaction liquid chromatography (HILIC) mixed-mode property. The stop-flow test revealed that C18-DTT exhibited excellent compatibility with 100% aqueous mobile phase. Additionally, the stability and column-to-column reproducibility of the C18-DTT material were satisfactory, with relative standard deviations of retention factor of the tested analytes (verapamil, fenbufen, guanine, tetrandrine and nicotinic acid) in the range of 1.82-3.72% and 0.85-1.93%, respectively. Finally, the application of C18-DTT column was demonstrated in the separation of non-steroidal anti-inflammatory drugs, aromatic carboxylic acids, alkaloids, nucleo-analytes and polycyclic aromatic hydrocarbons. It had great resolving power in the analysis of various compounds in HILIC and RPLC chromatographic conditions and was a promising RPLC/HILIC mixed-mode stationary phase. Copyright © 2015 Elsevier B.V. All rights reserved.
Human-Automation Interaction Design for Adaptive Cruise Control Systems of Ground Vehicles.
Eom, Hwisoo; Lee, Sang Hun
2015-06-12
A majority of recently developed advanced vehicles have been equipped with various automated driver assistance systems, such as adaptive cruise control (ACC) and lane keeping assistance systems. ACC systems have several operational modes, and drivers can be unaware of the mode in which they are operating. Because mode confusion is a significant human error factor that contributes to traffic accidents, it is necessary to develop user interfaces for ACC systems that can reduce mode confusion. To meet this requirement, this paper presents a new human-automation interaction design methodology in which the compatibility of the machine and interface models is determined using the proposed criteria, and if the models are incompatible, one or both of the models is/are modified to make them compatible. To investigate the effectiveness of our methodology, we designed two new interfaces by separately modifying the machine model and the interface model and then performed driver-in-the-loop experiments. The results showed that modifying the machine model provides a more compact, acceptable, effective, and safe interface than modifying the interface model.
Human-Automation Interaction Design for Adaptive Cruise Control Systems of Ground Vehicles
Eom, Hwisoo; Lee, Sang Hun
2015-01-01
A majority of recently developed advanced vehicles have been equipped with various automated driver assistance systems, such as adaptive cruise control (ACC) and lane keeping assistance systems. ACC systems have several operational modes, and drivers can be unaware of the mode in which they are operating. Because mode confusion is a significant human error factor that contributes to traffic accidents, it is necessary to develop user interfaces for ACC systems that can reduce mode confusion. To meet this requirement, this paper presents a new human-automation interaction design methodology in which the compatibility of the machine and interface models is determined using the proposed criteria, and if the models are incompatible, one or both of the models is/are modified to make them compatible. To investigate the effectiveness of our methodology, we designed two new interfaces by separately modifying the machine model and the interface model and then performed driver-in-the-loop experiments. The results showed that modifying the machine model provides a more compact, acceptable, effective, and safe interface than modifying the interface model. PMID:26076406
Reproductive biology of the native forage grass Trichloris crinita (Poaceae, Chloridoideae).
Kozub, P C; Barboza, K; Galdeano, F; Quarin, C L; Cavagnaro, J B; Cavagnaro, P F
2017-05-01
Trichloris crinita is a perennial forage grass species native to arid regions of the American continent. Due to its extensive area of distribution, good forage quality and resistance to drought and grazing, this species is widely utilised as forage and for revegetation purposes in environments with low water availability. Despite its importance, genetic improvement of T. crinita has been very limited, partly as consequence of the lack of knowledge on its mode of reproduction. In the present work, we studied the reproductive biology of T. crinita by means of embryological analyses, flow cytometric seed screen (FCSS), self-compatibility tests and progeny testing with morphological and molecular markers. Cytological analyses revealed embryo sacs with eight nuclei and of Polygonum type for all T. crinita accessions analysed. FCSS histograms exhibited two clear peaks corresponding to 2C and 3C DNA content, indicating embryo sacs of sexual origin. Controlled pollination experiments designed to evaluate seed set (%) demonstrated that T. crinita is self-compatible, whereas results from morphological and simple sequence repeat (SSR) marker analysis of progeny revealed lack of outcrossing. Together, these results indicate that T. crinita reproduces sexually. It is a self-compatible and autogamous species. It is expected that these data will have a positive impact in the genetics and breeding of this species, and therefore contribute to its proper utilisation in arid regions. © 2017 German Botanical Society and The Royal Botanical Society of the Netherlands.
OpenSimulator Interoperability with DRDC Simulation Tools: Compatibility Study
2014-09-01
into two components: (1) backend data services consisting of user accounts, login service, assets, and inventory; and (2) the simulator server which...components are combined into a single OpenSimulator process. In grid mode, the two components are separated, placing the backend services into a ROBUST... mobile devices. Potential points of compatibility between Unity and OpenSimulator include: a Unity-based desktop computer OpenSimulator viewer; a
Frequency-bin entanglement of ultra-narrow band non-degenerate photon pairs
NASA Astrophysics Data System (ADS)
Rieländer, Daniel; Lenhard, Andreas; Jime`nez Farìas, Osvaldo; Máttar, Alejandro; Cavalcanti, Daniel; Mazzera, Margherita; Acín, Antonio; de Riedmatten, Hugues
2018-01-01
We demonstrate frequency-bin entanglement between ultra-narrowband photons generated by cavity enhanced spontaneous parametric down conversion. Our source generates photon pairs in widely non-degenerate discrete frequency modes, with one photon resonant with a quantum memory material based on praseodymium doped crystals and the other photon at telecom wavelengths. Correlations between the frequency modes are analyzed using phase modulators and narrowband filters before detection. We show high-visibility two photon interference between the frequency modes, allowing us to infer a coherent superposition of the modes. We develop a model describing the state that we create and use it to estimate optimal measurements to achieve a violation of the Clauser-Horne (CH) Bell inequality under realistic assumptions. With these settings we perform a Bell test and show a significant violation of the CH inequality, thus proving the entanglement of the photons. Finally we demonstrate the compatibility with a quantum memory material by using a spectral hole in the praseodymium (Pr) doped crystal as spectral filter for measuring high-visibility two-photon interference. This demonstrates the feasibility of combining frequency-bin entangled photon pairs with Pr-based solid state quantum memories.
Intelsat TDMA and its implementation in Australia
NASA Astrophysics Data System (ADS)
Howe, Stuart
The developmental history and characteristics of the Intelsat digital communications network are surveyed, with a focus on the current implementation status in Australia. Topics addressed include the fundamental principles and advantages of a TDMA system, the hardware required for a TDMA traffic station, and the Intelsat Indian Ocean Primary satellite network. Detailed consideration is given to TDMA test equipment (burst-mode link analyzers, PCM DSI test sets, burst-power meters, burst negators, and reference burst generators), terminal integration with terrestrial and RF links (TWT sharing and equalization), equipment compatibility, and traffic. Plans call for 950 TDMA circuits by the end of 1990, representing about 36.5 percent of the traffic between Australia and Europe, Africa, India and Pakistan, and the Middle East.
Three-dimensional whispering gallery modes in InGaAs nanoneedle lasers on silicon
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tran, T.-T. D.; Chen, R.; Ng, K. W.
2014-09-15
As-grown InGaAs nanoneedle lasers, synthesized at complementary metal–oxide–semiconductor compatible temperatures on polycrystalline and crystalline silicon substrates, were studied in photoluminescence experiments. Radiation patterns of three-dimensional whispering gallery modes were observed upon optically pumping the needles above the lasing threshold. Using the radiation patterns as well as finite-difference-time-domain simulations and polarization measurements, all modal numbers of the three-dimensional whispering gallery modes could be identified.
Schatzl, Magdalena; Hackl, Florian; Glaser, Martin; Rauter, Patrick; Brehm, Moritz; Spindlberger, Lukas; Simbula, Angelica; Galli, Matteo; Fromherz, Thomas; Schäffler, Friedrich
2017-03-15
Efficient coupling to integrated high-quality-factor cavities is crucial for the employment of germanium quantum dot (QD) emitters in future monolithic silicon-based optoelectronic platforms. We report on strongly enhanced emission from single Ge QDs into L3 photonic crystal resonator (PCR) modes based on precise positioning of these dots at the maximum of the respective mode field energy density. Perfect site control of Ge QDs grown on prepatterned silicon-on-insulator substrates was exploited to fabricate in one processing run almost 300 PCRs containing single QDs in systematically varying positions within the cavities. Extensive photoluminescence studies on this cavity chip enable a direct evaluation of the position-dependent coupling efficiency between single dots and selected cavity modes. The experimental results demonstrate the great potential of the approach allowing CMOS-compatible parallel fabrication of arrays of spatially matched dot/cavity systems for group-IV-based data transfer or quantum optical systems in the telecom regime.
2017-01-01
Efficient coupling to integrated high-quality-factor cavities is crucial for the employment of germanium quantum dot (QD) emitters in future monolithic silicon-based optoelectronic platforms. We report on strongly enhanced emission from single Ge QDs into L3 photonic crystal resonator (PCR) modes based on precise positioning of these dots at the maximum of the respective mode field energy density. Perfect site control of Ge QDs grown on prepatterned silicon-on-insulator substrates was exploited to fabricate in one processing run almost 300 PCRs containing single QDs in systematically varying positions within the cavities. Extensive photoluminescence studies on this cavity chip enable a direct evaluation of the position-dependent coupling efficiency between single dots and selected cavity modes. The experimental results demonstrate the great potential of the approach allowing CMOS-compatible parallel fabrication of arrays of spatially matched dot/cavity systems for group-IV-based data transfer or quantum optical systems in the telecom regime. PMID:28345012
Traffic Aware Strategic Aircrew Requests (TASAR) Concept of Operations
NASA Technical Reports Server (NTRS)
Henderson, Jeffrey
2013-01-01
Aircrews submit trajectory change requests to air traffic control (ATC) to better achieve the operator's preferred business trajectory. Requests are currently made with limited information and are often denied because the change is not compatible with traffic. Also, request opportunities can be overlooked due to lack of automation that advises aircrews of trajectory changes that improve flight time, fuel burn, and other objectives. The Traffic Aware Strategic Aircrew Requests (TASAR) concept leverages Automatic Dependent Surveillance-Broadcast (ADS-B) surveillance information to advise the aircrew of beneficial trajectory changes that are probed for traffic compatibility prior to issuing the request to ATC. This document describes the features, benefits, and limitations of TASAR automation hosted on an Electronic Flight Bag. TASAR has two modes: (1) auto mode that continuously assesses opportunities for improving the performance of the flight and (2) manual mode that probes trajectory changes entered by aircrews for conflicts and performance objectives. The roles and procedures of the aircrew and ATC remain unchanged under TASAR.
Arc fusion splicing of photonic crystal fibers to standard single mode fibers
NASA Astrophysics Data System (ADS)
Borzycki, Krzysztof; Kobelke, Jens; Schuster, Kay; Wójcik, Jan
2010-04-01
Coupling a photonic crystal fiber (PCF) to measuring instruments or optical subsystems is often done by splicing it to short lengths of single mode fiber (SMF) used for interconnections, as SMF is standardized, widely available and compatible with most fiber optic components and measuring instruments. This paper presents procedures and results of loss measurements during fusion splicing of five PCFs tested at NIT laboratory within activities of COST Action 299 "FIDES". Investigated silica-based fibers had 80-200 μm cladding diameter and were designed as single mode. A standard splicing machine designed for telecom fibers was used, but splicing procedure and arc power were tailored to each PCF. Splice loss varied between 0.7 and 2.8 dB at 1550 nm. Splices protected with heat-shrinkable sleeves served well for gripping fibers during mechanical tests and survived temperature cycling from -30°C to +70°C with stable loss. Collapse of holes in the PCF was limited by reducing fusion time to 0.2-0.5 s; additional measures included reduction of discharge power and shifting SMF-PCF contact point away from the axis of electrodes. Unfortunately, short fusion time sometimes precluded proper smoothing of glass surface, leading to a trade-off between splice loss and strength.
CMOS-Compatible Fabrication for Photonic Crystal-Based Nanofluidic Structure.
Peng, Wang; Chen, Youping; Ai, Wu; Zhang, Dailin; Song, Han; Xiong, Hui; Huang, Pengcheng
2017-12-01
Photonic crystal (PC)-based devices have been widely used since 1990s, while PC has just stepped into the research area of nanofluidic. In this paper, photonic crystal had been used as a complementary metal oxide semiconductors (CMOS) compatible part to create a nanofluidic structure. A nanofluidic structure prototype had been fabricated with CMOS-compatible techniques. The nanofluidic channels were sealed by direct bonding polydimethylsiloxane (PDMS) and the periodic gratings on photonic crystal structure. The PC was fabricated on a 4-in. Si wafer with Si 3 N 4 as the guided mode layer and SiO 2 film as substrate layer. The higher order mode resonance wavelength of PC-based nanofluidic structure had been selected, which can confine the enhanced electrical field located inside the nanochannel area. A design flow chart was used to guide the fabrication process. By optimizing the fabrication device parameters, the periodic grating of PC-based nanofluidic structure had a high-fidelity profile with fill factor at 0.5. The enhanced electric field was optimized and located within the channel area, and it can be used for PC-based nanofluidic applications with high performance.
NASA Technical Reports Server (NTRS)
Beeson, Harold D.; Davis, Dennis D.; Ross, William L., Sr.; Tapphorn, Ralph M.
2002-01-01
This document represents efforts accomplished at the NASA Johnson Space Center White Sands Test Facility (WSTF) in support of the Enhanced Technology for Composite Overwrapped Pressure Vessels (COPV) Program, a joint research and technology effort among the U.S. Air Force, NASA, and the Aerospace Corporation. WSTF performed testing for several facets of the program. Testing that contributed to the Task 3.0 COPV database extension objective included baseline structural strength, failure mode and safe-life, impact damage tolerance, sustained load/impact effect, and materials compatibility. WSTF was also responsible for establishing impact protection and control requirements under Task 8.0 of the program. This included developing a methodology for establishing an impact control plan. Seven test reports detail the work done at WSTF. As such, this document contributes to the database of information regarding COPV behavior that will ensure performance benefits and safety are maintained throughout vessel service life.
Wu, Hao; Wang, Ruoxu; Liu, Deming; Fu, Songnian; Zhao, Can; Wei, Huifeng; Tong, Weijun; Shum, Perry Ping; Tang, Ming
2016-04-01
We proposed and demonstrated a few-mode fiber (FMF) based optical-fiber sensor for distributed curvature measurement through quasi-single-mode Brillouin frequency shift (BFS). By central-alignment splicing FMF and single-mode fiber (SMF) with a fusion taper, a SMF-components-compatible distributed curvature sensor based on FMF is realized using the conventional Brillouin optical time-domain analysis system. The distributed BFS change induced by bending in FMF has been theoretically and experimentally investigated. The precise BFS response to the curvature along the fiber link has been calibrated. A proof-of-concept experiment is implemented to validate its effectiveness in distributed curvature measurement.
Evolutionary Model and Oscillation Frequencies for α Ursae Majoris: A Comparison with Observations
NASA Astrophysics Data System (ADS)
Guenther, D. B.; Demarque, P.; Buzasi, D.; Catanzarite, J.; Laher, R.; Conrow, T.; Kreidl, T.
2000-02-01
Inspired by the observations of low-amplitude oscillations of α Ursae Majoris A by Buzasi et al. using the WIRE satellite, a grid of stellar evolutionary tracks has been constructed to derive physically consistent interior models for the nearby red giant. The pulsation properties of these models were then calculated and compared with the observations. It is found that, by adopting the correct metallicity and for a normal helium abundance, only models in the mass range of 4.0-4.5 Msolar fall within the observational error box for α UMa A. This mass range is compatible, within the uncertainties, with the mass derived from the astrometric mass function. Analysis of the pulsation spectra of the models indicates that the observed α UMa oscillations can be most simply interpreted as radial (i.e., l=0) p-mode oscillations of low radial order n. The lowest frequencies observed by Buzasi et al. are compatible, within the observational errors, with model frequencies of radial orders n=0, 1, and 2 for models in the mass range of 4.0-4.5 Msolar. The higher frequencies observed can also be tentatively interpreted as higher n-valued radial p-modes, if we allow that some n-values are not presently observed. The theoretical l=1, 2, and 3 modes in the observed frequency range are g-modes with a mixed mode character, that is, with p-mode-like characteristics near the surface and g-mode-like characteristics in the interior. The calculated radial p-mode frequencies are nearly equally spaced, separated by 2-3 μHz. The nonradial modes are very densely packed throughout the observed frequency range and, even if excited to significant amplitudes at the surface, are unlikely to be resolved by the present observations.
Build your own low-cost seismic/bathymetric recorder annotator
Robinson, W.
1994-01-01
An inexpensive programmable annotator, completely compatible with at least three models of widely used graphic recorders (Raytheon LSR-1811, Raytheon LSR-1807 M, and EDO 550) has been developed to automatically write event marks and print up to sixteen numbers on the paper record. Event mark and character printout intervals, character height and character position are all selectable with front panel switches. Operation is completely compatible with recorders running in either continuous or start-stop mode. ?? 1994.
Jones, Adam M; DeRose, Christopher T; Lentine, Anthony L; Trotter, Douglas C; Starbuck, Andrew L; Norwood, Robert A
2013-05-20
We explore the design space for optimizing CMOS compatible waveguide crossings on a silicon photonics platform. This paper presents simulated and experimental excess loss and crosstalk suppression data for vertically integrated silicon nitride over silicon-on-insulator waveguide crossings. Experimental results show crosstalk suppression exceeding -49/-44 dB with simulation results as low as -65/-60 dB for the TE/TM mode in a waveguide crossing with a 410 nm vertical gap.
Analysis of Motorcycle Weave Mode by using Energy Flow Method
NASA Astrophysics Data System (ADS)
Marumo, Yoshitaka; Katayama, Tsuyoshi
The activation mechanism of motorcycle weave mode is clarified within the framework of the energy flow method, which calculates energy flow of mechanical forces in each motion. It is demonstrated that only a few mechanical forces affect the stability of the weave mode from among a total of about 40 mechanical forces. The activation of the lateral, yawing and rolling motions destabilize the weave mode, while activation of the steering motion stabilizes the weave mode. A detailed investigation of the energy flow of the steering motion reveals that the steering motion plays an important role in clarifying the characteristics of the weave mode. As activation of the steering motion progresses the phase of the front tire side force, and the weave mode is consequently stabilized. This paper provides a design guide for stabilizing the weave mode and the wobble mode compatibility.
Mutual interferences and design principles for mechatronic devices in magnetic resonance imaging.
Yu, Ningbo; Gassert, Roger; Riener, Robert
2011-07-01
Robotic and mechatronic devices that work compatibly with magnetic resonance imaging (MRI) are applied in diagnostic MRI, image-guided surgery, neurorehabilitation and neuroscience. MRI-compatible mechatronic systems must address the challenges imposed by the scanner's electromagnetic fields. We have developed objective quantitative evaluation criteria for device characteristics needed to formulate design guidelines that ensure MRI-compatibility based on safety, device functionality and image quality. The mutual interferences between an MRI system and mechatronic devices working in its vicinity are modeled and tested. For each interference, the involved components are listed, and a numerical measure for "MRI-compatibility" is proposed. These interferences are categorized into an MRI-compatibility matrix, with each element representing possible interactions between one part of the mechatronic system and one component of the electromagnetic fields. Based on this formulation, design principles for MRI-compatible mechatronic systems are proposed. Furthermore, test methods are developed to examine whether a mechatronic device indeed works without interferences within an MRI system. Finally, the proposed MRI-compatibility criteria and design guidelines have been applied to an actual design process that has been validated by the test procedures. Objective and quantitative MRI-compatibility measures for mechatronic and robotic devices have been established. Applying the proposed design principles, potential problems in safety, device functionality and image quality can be considered in the design phase to ensure that the mechatronic system will fulfill the MRI-compatibility criteria. New guidelines and test procedures for MRI instrument compatibility provide a rational basis for design and evaluation of mechatronic devices in various MRI applications. Designers can apply these criteria and use the tests, so that MRI-compatibility results can accrue to build an experiential database.
NASA Astrophysics Data System (ADS)
Cárdenas Moctezuma, A.; Torres Guzmán, J. C.
2016-01-01
CENAM, through the Force and Pressure Division, organized a comparison on testing machines calibration, in compression mode. The participating laboratories were SIM National Institutes of Metrology from Colombia, Peru and Costa Rica, where CENAM, Mexico was the pilot and reference laboratory. The results obtained by the laboratories are presented in this paper as well as the analysis of compatibility. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
High power and single mode quantum cascade lasers.
Bismuto, Alfredo; Bidaux, Yves; Blaser, Stéphane; Terazzi, Romain; Gresch, Tobias; Rochat, Michel; Muller, Antoine; Bonzon, Christopher; Faist, Jerome
2016-05-16
We present a single mode quantum cascade laser with nearly 1 W optical power. A buried distributed feedback reflector is used on the back section for wavelength selection. The laser is 6 mm long, 3.5 μm wide, mounted episide-up and the laser facets are left uncoated. Laser emission is centered at 4.68 μm. Single-mode operation with a side mode suppression ratio of more than 30 dB is obtained in whole range of operation. Farfield measurements prove a symmetric, single transverse-mode emission in TM00-mode with typical divergences of 41° and 33° in the vertical and horizontal direction respectively. This work shows the potential for simple fabrication of high power lasers compatible with standard DFB processing.
Phillips, Steven; Wilson, William H.
2011-01-01
A complete theory of cognitive architecture (i.e., the basic processes and modes of composition that together constitute cognitive behaviour) must explain the systematicity property—why our cognitive capacities are organized into particular groups of capacities, rather than some other, arbitrary collection. The classical account supposes: (1) syntactically compositional representations; and (2) processes that are sensitive to—compatible with—their structure. Classical compositionality, however, does not explain why these two components must be compatible; they are only compatible by the ad hoc assumption (convention) of employing the same mode of (concatenative) compositionality (e.g., prefix/postfix, where a relation symbol is always prepended/appended to the symbols for the related entities). Architectures employing mixed modes do not support systematicity. Recently, we proposed an alternative explanation without ad hoc assumptions, using category theory. Here, we extend our explanation to domains that are quasi-systematic (e.g., aspects of most languages), where the domain includes some but not all possible combinations of constituents. The central category-theoretic construct is an adjunction involving pullbacks, where the primary focus is on the relationship between processes modelled as functors, rather than the representations. A functor is a structure-preserving map (or construction, for our purposes). An adjunction guarantees that the only pairings of functors are the systematic ones. Thus, (quasi-)systematicity is a necessary consequence of a categorial cognitive architecture whose basic processes are functors that participate in adjunctions. PMID:21857816
Characterization of Geiger mode avalanche photodiodes for fluorescence decay measurements
NASA Astrophysics Data System (ADS)
Jackson, John C.; Phelan, Don; Morrison, Alan P.; Redfern, R. Michael; Mathewson, Alan
2002-05-01
Geiger mode avalanche photodiodes (APD) can be biased above the breakdown voltage to allow detection of single photons. Because of the increase in quantum efficiency, magnetic field immunity, robustness, longer operating lifetime and reduction in costs, solid-state detectors capable of operating at non-cryogenic temperatures and providing single photon detection capabilities provide attractive alternatives to the photomultiplier tube (PMT). Shallow junction Geiger mode APD detectors provide the ability to manufacture photon detectors and detector arrays with CMOS compatible processing steps and allows the use of novel Silicon-on-Insulator(SoI) technology to provide future integrated sensing solutions. Previous work on Geiger mode APD detectors has focused on increasing the active area of the detector to make it more PMT like, easing the integration of discrete reaction, detection and signal processing into laboratory experimental systems. This discrete model for single photon detection works well for laboratory sized test and measurement equipment, however the move towards microfluidics and systems on a chip requires integrated sensing solutions. As we move towards providing integrated functionality of increasingly nanoscopic sized emissions, small area detectors and detector arrays that can be easily integrated into marketable systems, with sensitive small area single photon counting detectors will be needed. This paper will demonstrate the 2-dimensional and 3-dimensional simulation of optical coupling that occurs in Geiger mode APDs. Fabricated Geiger mode APD detectors optimized for fluorescence decay measurements were characterized and preliminary results show excellent results for their integration into fluorescence decay measurement systems.
NASA Technical Reports Server (NTRS)
Tucker, W. B.; Hooper, H. L.
1963-01-01
This report presents two fundamental properties of lunar trajectories and makes use of these properties to solve various lunar landing site problems. Not only are various problems treated and solved but the properties and methods are established for use in the solution of other problems. This report presents an analysis of lunar landing site problems utilizing the direct mission mode as well as the orbital mission mode. A particular landing site is then specified and different flight profiles are analyzed for getting an exploration vehicle to that landing site. Rendezvous compatible lunar orbits for various stay-times at the landing site are treated. Launch opportunities are discussed for establishing rendezvous compatible lunar orbits without powered plane changes. Then, the minimum required plane changes for rendezvous in the lunar orbit are discussed for launching from earth on any day. On days that afford rendezvous compatible opportunities, there are no powered plane change requirements in the operations from launch at AMR through the rendezvous in lunar orbit, after the stay at the lunar site.
Kinetic Modeling Sheds Light on the Mode of Action of Recombinant Factor VIIa on Thrombin Generation
2011-01-01
Regular Article Kinetic modeling sheds light on the mode of action of recombinant factor VIIa on thrombin generation Alexander Y. Mitrophanov...its effects on the quantitative parameters of thrombin generation. For recombinant activated factor VII (rFVIIa) ― a promising hemostasis-inducing...modulate thrombin production , it is necessary to identify rFVIIa-induced effects that are compatible with the available biochemical knowledge about
Microsoft PowerPoint - Walter Coke Comm May 19 Karen correction presentation [Compatibility Mode
Contains slides from a presentation to Collegeville, Harriman Park, and Fairmont neighborhoods in North Birmingham, Alabama updating the community on the environmental sampling and next steps on the Walter Coke cleanup site.
Compatibility of information and mode of control: The case for natural control systems
NASA Technical Reports Server (NTRS)
Owen, Dean H.
1993-01-01
The operation of control systems has been determined largely by mechanical constraints. Compatibility with the characteristics of the operator is a secondary consideration, with the result that control may never be optimal, control workload may interfere with performance of secondary tasks, and learning may be more difficult and protracted than necessary. With the introduction of a computer in the control loop, the mode of operation can be adapted to the operator, rather than vice versa. The concept of natural control is introduced to describe a system that supports control of the information used by the operator in achieving an intended goal. As an example, control of speed during simulated approach to a pad by helicopter pilots is used to contrast path-speed control with direct control of global optical flow-pattern information. Differences are evidenced in the performance domains of control activity, speed, and global optical flow velocity.
Effect of control surface mass unbalance on the stability of a closed-loop active control system
NASA Technical Reports Server (NTRS)
Nissim, E.
1989-01-01
The effects on stability of inertial forces arising from closed-loop activation of mass-unbalanced control surfaces are studied analytically using inertial energy approach, similar to the aerodynamic energy approach used for flutter suppression. The limitations of a single control surface like a leading-edge (LE) control or a trailing-edge (TE) control are demonstrated and compared to the superior combined LE-TE mass unbalanced system. It is shown that a spanwise section for sensor location can be determined which ensures minimum sensitivity to the mode shapes of the aircraft. It is shown that an LE control exhibits compatibility between inertial stabilization and aerodynamic stabilization, and that a TE control lacks such compatibility. The results of the present work should prove valuable, both for the purpose of flutter suppression using mass unbalanced control surfaces, or for the stabilization of structural modes of large space structures by means of inertial forces.
Monolithically integrated Si gate-controlled light-emitting device: science and properties
NASA Astrophysics Data System (ADS)
Xu, Kaikai
2018-02-01
The motivation of this study is to develop a p-n junction based light emitting device, in which the light emission is conventionally realized using reverse current driving, by voltage driving. By introducing an additional terminal of insulated gate for voltage driving, a novel three-terminal Si light emitting device is described where both the light intensity and spatial light pattern of the device are controlled by the gate voltage. The proposed light emitting device employs injection-enhanced Si in avalanche mode where electric field confinement occurs in the corner of a reverse-biased p+n junction. It is found that, depending on the bias conditions, the light intensity is either a linear or a quadratic function of the applied gate voltage or the reverse-bias. Since the light emission is based on the avalanching mode, the Si light emitting device offers the potential for very large scale integration-compatible light emitters for inter- or intra-chip signal transmission and contactless functional testing of wafers.
NASA Technical Reports Server (NTRS)
Walker, J. W.; Hornbeck, L. J.; Stubbs, D. P.
1977-01-01
The results are presented of a program to design, fabricate, and test CCD arrays suitable for operation in an electron-bombarded mode. These intensified charge coupled devices have potential application to astronomy as photon-counting arrays. The objectives of this program were to deliver arrays of 250 lines of 400 pixels each and some associated electronics. Some arrays were delivered on tube-compatible headers and some were delivered after incorporation in vacuum tubes. Delivery of these devices required considerable improvements to be made in the processing associated with intensified operation. These improvements resulted in a high yield in the thinning process, reproducible results in the accumulation process, elimination of a dark current source in the accumulation process, solution of a number of header related problems, and the identification of a remaining major source of dark current. Two systematic failure modes were identified and protective measures established. The effects of tube processing on the arrays in the delivered ICCDs were determined and are reported along with the characterization data on the arrays.
Volatile organic compounds discrimination based on dual mode detection
NASA Astrophysics Data System (ADS)
Yu, Yuanyuan; Wu, Enxiu; Chen, Yan; Feng, Zhihong; Zheng, Shijun; Zhang, Hao; Pang, Wei; Liu, Jing; Zhang, Daihua
2018-06-01
We report on a volatile organic compound (VOC) sensor that can provide concentration-independent signals toward target gases. The device is based on a dual-mode detection mechanism that can simultaneously record the mechanical (resonant frequency, f r) and electrical (current, I) responses of the same gas adsorption event. The two independent signals form a unique I–f r trace for each target VOC as the concentration varies. The mechanical response (frequency shift, Δf r) resulting from mass load on the device is directly related to the amount of surface adsorptions, while the electrical response (current variation, ΔI) is associated with charge transfer across the sensing interface and changes in carrier mobility. The two responses resulting from independent physical processes reflect intrinsic physical properties of each target gas. The ΔI–Δf r trace combined with the concentration dependent frequency (or current) signals can therefore be used to achieve target both recognition and quantification. The dual-mode device is designed and fabricated using standard complementary metal oxide semiconductor (CMOS) compatible processes. It exhibits consistent and stable performance in our tests with six different VOCs including ethanol, methanol, acetone, formaldehyde, benzene and hexane.
Volatile organic compounds discrimination based on dual mode detection.
Yu, Yuanyuan; Wu, Enxiu; Chen, Yan; Feng, Zhihong; Zheng, Shijun; Zhang, Hao; Pang, Wei; Liu, Jing; Zhang, Daihua
2018-06-15
We report on a volatile organic compound (VOC) sensor that can provide concentration-independent signals toward target gases. The device is based on a dual-mode detection mechanism that can simultaneously record the mechanical (resonant frequency, f r ) and electrical (current, I) responses of the same gas adsorption event. The two independent signals form a unique I-f r trace for each target VOC as the concentration varies. The mechanical response (frequency shift, Δf r ) resulting from mass load on the device is directly related to the amount of surface adsorptions, while the electrical response (current variation, ΔI) is associated with charge transfer across the sensing interface and changes in carrier mobility. The two responses resulting from independent physical processes reflect intrinsic physical properties of each target gas. The ΔI-Δf r trace combined with the concentration dependent frequency (or current) signals can therefore be used to achieve target both recognition and quantification. The dual-mode device is designed and fabricated using standard complementary metal oxide semiconductor (CMOS) compatible processes. It exhibits consistent and stable performance in our tests with six different VOCs including ethanol, methanol, acetone, formaldehyde, benzene and hexane.
Test operations procedure (TOP) 1-2-512 electromagnetic compatibility tests
NASA Astrophysics Data System (ADS)
1995-05-01
This TOP provides guidance for the planning, execution, and reporting of grounding and bonding and electromagnetic compatibility (EMC) tests of electrical, electronic, and electrochemical equipment, subsystems, and systems.
2010-09-01
modèles à orientation opérationnelle ( comparativement à ceux orientés vers la recherche) qui pourraient être compatibles avec le modèle de propagation...concentre sur les modèles à orientation opérationnelle (en sacrifiant un certain degré d’exactitude pour accroître la réactivité, comparativement aux modèles...these modeling efforts are not applicable to Bellhop because they are designed specifically to take advantage of the normal mode decomposition
Compatibility Studies of Hydrogen Peroxide and a New Hypergolic Fuel Blend
NASA Technical Reports Server (NTRS)
Baldridge, Jennifer; Villegas, Yvonne
2002-01-01
Several preliminary materials compatibility studies have been conducted to determine the practicality of a new hypergolic fuel system. Hypergolic fuel ignites spontaneously as the oxidizer decomposes and releases energy in the presence of the fuel. The bipropellant system tested consists of high-test hydrogen peroxide (HTP) and a liquid fuel blend consisting of a hydrocarbon fuel, an ignition enhancer and a transition metal catalyst. In order for further testing of the new fuel blend to take place, some basic materials compatibility and HTP decomposition studies must be accomplished. The thermal decomposition rate of HTP was tested using gas evolution and isothermal microcalorimetry (IMC). Materials were analyzed for compatibility with hydrogen peroxide including a study of the affect welding has on stainless steel elemental composition and its relation to HTP decomposition. Compatibility studies of valve materials in the fuel blend were performed to determine the corrosion resistance of the materials.
Geostationary platform systems concepts definition study. Volume 2: Technical, book 1
NASA Technical Reports Server (NTRS)
1980-01-01
The initial selection and definition of operational geostationary platform concepts is discussed. Candidate geostationary platform missions and payloads were identified from COMSAT, Aerospace, and NASA studies. These missions and payloads were cataloged; classified with to communications, military, or scientific uses; screened for application and compatibility with geostationary platforms; and analyzed to identify platform requirements. Two platform locations were then selected (Western Hemisphere - 110 deg W, and Atlantic - 15 deg W), and payloads allocated based on nominal and high traffic models. Trade studies were performed leading to recommendation of selected concepts. Of 30 Orbit Transfer Vehicle (0TV) configuration and operating mode options identified, 18 viable candidates compatible with the operational geostationary platform missions were selected for analysis. Each was considered using four platform operational modes - 8 or 16 year life, and serviced or nonserviced, providing a total of 72 OTV/platform-mode options. For final trade study concept selection, a cost program was developed considering payload and platform costs and weight; transportation unit and total costs for the shuttle and OTV; and operational costs such as assembly or construction time, mating time, and loiter time. Servicing costs were added for final analysis and recommended selection.
Breeding graft-compatible Douglas-fir rootstocks (Pseudotsuga menziesii (Mirb.) Franco).
D.L. Copes
1999-01-01
A study encompassing 24 years was conducted to determine if a breeding program could produce highly graft-compatible rootstocks. Twenty-seven trees of apparent high graft compatibility were selected and crossed to produce 226 control-pollinated families. Seedlings were grown, field planted, and grafted with test scions. Graft unions from field tests were evaluated...
Hydrocarbon-fuel/combustion-chamber-liner materials compatibility
NASA Technical Reports Server (NTRS)
Gage, Mark L.
1990-01-01
Results of material compatibility experiments using hydrocarbon fuels in contact with copper-based combustion chamber liner materials are presented. Mil-Spec RP-1, n- dodecane, propane, and methane fuels were tested in contact with OFHC, NASA-Z, and ZrCu coppers. Two distinct test methods were employed. Static tests, in which copper coupons were exposed to fuel for long durations at constant temperature and pressure, provided compatibility data in a precisely controlled environment. Dynamic tests, using the Aerojet Carbothermal Test Facility, provided fuel and copper compatibility data under realistic booster engine service conditions. Tests were conducted using very pure grades of each fuel and fuels to which a contaminant, e.g., ethylene or methyl mercaptan, was added to define the role played by fuel impurities. Conclusions are reached as to degradation mechanisms and effects, methods for the elimination of these mechanisms, selection of copper alloy combustion chamber liners, and hydrocarbon fuel purchase specifications.
Statistical EMC: A new dimension electromagnetic compatibility of digital electronic systems
NASA Astrophysics Data System (ADS)
Tsaliovich, Anatoly
Electromagnetic compatibility compliance test results are used as a database for addressing three classes of electromagnetic-compatibility (EMC) related problems: statistical EMC profiles of digital electronic systems, the effect of equipment-under-test (EUT) parameters on the electromagnetic emission characteristics, and EMC measurement specifics. Open area test site (OATS) and absorber line shielded room (AR) results are compared for equipment-under-test highest radiated emissions. The suggested statistical evaluation methodology can be utilized to correlate the results of different EMC test techniques, characterize the EMC performance of electronic systems and components, and develop recommendations for electronic product optimal EMC design.
Preparation of refractory cermet structures for lithium compatibility testing
NASA Technical Reports Server (NTRS)
Heestand, R. L.; Jones, R. A.; Wright, T. R.; Kizer, D. E.
1973-01-01
High-purity nitride and carbide cermets were synthesized for compatability testing in liquid lithium. A process was developed for the preparation of high-purity hafnium nitride powder, which was subsequently blended with tungsten powder or tantalum nitride and tungsten powders and fabricated into 3 in diameter billets by uniaxial hot pressing. Specimens were then cut from the billets for compatability testing. Similar processing techniques were applied to produce hafnium carbide and zirconium carbide cermets for use in the testing program. All billets produced were characterized with respect to chemistry, structure, density, and strength properties.
On-chip WDM mode-division multiplexing interconnection with optional demodulation function.
Ye, Mengyuan; Yu, Yu; Chen, Guanyu; Luo, Yuchan; Zhang, Xinliang
2015-12-14
We propose and fabricate a wavelength-division-multiplexing (WDM) compatible and multi-functional mode-division-multiplexing (MDM) integrated circuit, which can perform the mode conversion and multiplexing for the incoming multipath WDM signals, avoiding the wavelength conflict. An phase-to-intensity demodulation function can be optionally applied within the circuit while performing the mode multiplexing. For demonstration, 4 × 10 Gb/s non-return-to-zero differential phase shift keying (NRZ-DPSK) signals are successfully processed, with open and clear eye diagrams. Measured bit error ratio (BER) results show less than 1 dB receive sensitivity variation for three modes and four wavelengths with demodulation. In the case without demodulation, the average power penalties at 4 wavelengths are -1.5, -3 and -3.5 dB for TE₀-TE₀, TE₀-TE₁ and TE₀-TE₂ mode conversions, respectively. The proposed flexible scheme can be used at the interface of long-haul and on-chip communication systems.
Effect of Background Pressure on the Plasma Oscillation Characteristics of the HiVHAc Hall Thruster
NASA Technical Reports Server (NTRS)
Huang, Wensheng; Kamhawi, Hani; Lobbia, Robert B.; Brown, Daniel L.
2014-01-01
During a component compatibility test of the NASA HiVHAc Hall thruster, a number of plasma diagnostics were implemented to study the effect of varying facility background pressure on thruster operation. These diagnostics characterized the thruster performance, the plume, and the plasma oscillations in the thruster. Thruster performance and plume characteristics as functions of background pressure were previously published. This paper focuses on changes in the plasma oscillation characteristics with changing background pressure. The diagnostics used to study plasma oscillations include a high-speed camera and a set of high-speed Langmuir probes. The results show a rise in the oscillation frequency of the "breathing" mode with rising background pressure, which is hypothesized to be due to a shortening acceleration/ionization zone. An attempt is made to apply a simplified ingestion model to the data. The combined results are used to estimate the maximum acceptable background pressure for performance and wear testing.
Free-decay time-domain modal identification for large space structures
NASA Technical Reports Server (NTRS)
Kim, Hyoung M.; Vanhorn, David A.; Doiron, Harold H.
1992-01-01
Concept definition studies for the Modal Identification Experiment (MIE), a proposed space flight experiment for the Space Station Freedom (SSF), have demonstrated advantages and compatibility of free-decay time-domain modal identification techniques with the on-orbit operational constraints of large space structures. Since practical experience with modal identification using actual free-decay responses of large space structures is very limited, several numerical and test data reduction studies were conducted. Major issues and solutions were addressed, including closely-spaced modes, wide frequency range of interest, data acquisition errors, sampling delay, excitation limitations, nonlinearities, and unknown disturbances during free-decay data acquisition. The data processing strategies developed in these studies were applied to numerical simulations of the MIE, test data from a deployable truss, and launch vehicle flight data. Results of these studies indicate free-decay time-domain modal identification methods can provide accurate modal parameters necessary to characterize the structural dynamics of large space structures.
The NASA/OAST telerobot testbed architecture
NASA Technical Reports Server (NTRS)
Matijevic, J. R.; Zimmerman, W. F.; Dolinsky, S.
1989-01-01
Through a phased development such as a laboratory-based research testbed, the NASA/OAST Telerobot Testbed provides an environment for system test and demonstration of the technology which will usefully complement, significantly enhance, or even replace manned space activities. By integrating advanced sensing, robotic manipulation and intelligent control under human-interactive supervision, the Testbed will ultimately demonstrate execution of a variety of generic tasks suggestive of space assembly, maintenance, repair, and telescience. The Testbed system features a hierarchical layered control structure compatible with the incorporation of evolving technologies as they become available. The Testbed system is physically implemented in a computing architecture which allows for ease of integration of these technologies while preserving the flexibility for test of a variety of man-machine modes. The development currently in progress on the functional and implementation architectures of the NASA/OAST Testbed and capabilities planned for the coming years are presented.
Copper nanorod array assisted silicon waveguide polarization beam splitter.
Kim, Sangsik; Qi, Minghao
2014-04-21
We present the design of a three-dimensional (3D) polarization beam splitter (PBS) with a copper nanorod array placed between two silicon waveguides. The localized surface plasmon resonance (LSPR) of a metal nanorod array selectively cross-couples transverse electric (TE) mode to the coupler waveguide, while transverse magnetic (TM) mode passes through the original input waveguide without coupling. An ultra-compact and broadband PBS compared to all-dielectric devices is achieved with the LSPR. The output ports of waveguides are designed to support either TM or TE mode only to enhance the extinction ratios. Compared to silver, copper is fully compatible with complementary metal-oxide-semiconductor (CMOS) technology.
Spatial mode discriminator based on leaky waveguides
NASA Astrophysics Data System (ADS)
Xu, Jing; Liu, Jialing; Shi, Hongkang; Chen, Yuntian
2018-06-01
We propose a conceptually simple and experimentally compatible configuration to discriminate the spatial mode based on leaky waveguides, which are inserted in-between the transmission link. The essence of such a spatial mode discriminator is to introduce the leakage of the power flux on purpose for detection. Importantly, the leaky angle of each individual spatial mode with respect to the propagation direction are different for non-degenerated modes, while the radiation patterns of the degenerated spatial modes in the plane perpendicular to the propagation direction are also distinguishable. Based on these two facts, we illustrate the operation principle of the spatial mode discriminators via two concrete examples; a w-type slab leaky waveguide without degeneracy, and a cylindrical leaky waveguide with degeneracy. The correlation between the leakage angle and the spatial mode distribution for a slab leaky waveguide, as well as differences between the in-plane radiation patterns of degenerated modes in a cylindrical leaky waveguide, are verified numerically and analytically. Such findings can be readily useful in discriminating the spatial modes for optical communication or optical sensing.
42 CFR 493.863 - Standard; Compatibility testing.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 5 2010-10-01 2010-10-01 false Standard; Compatibility testing. 493.863 Section 493.863 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... for Laboratories Performing Tests of Moderate Complexity (including the Subcategory), High Complexity...
42 CFR 493.863 - Standard; Compatibility testing.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 5 2011-10-01 2011-10-01 false Standard; Compatibility testing. 493.863 Section 493.863 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH AND HUMAN... for Laboratories Performing Tests of Moderate Complexity (including the Subcategory), High Complexity...
NASA Technical Reports Server (NTRS)
Roberts, Floyd E., III
1994-01-01
Software provides for control and acquisition of data from optical pyrometer. There are six individual programs in PYROLASER package. Provides quick and easy way to set up, control, and program standard Pyrolaser. Temperature and emisivity measurements either collected as if Pyrolaser in manual operating mode or displayed on real-time strip charts and stored in standard spreadsheet format for posttest analysis. Shell supplied to allow macros, which are test-specific, added to system easily. Written using Labview software for use on Macintosh-series computers running System 6.0.3 or later, Sun Sparc-series computers running Open-Windows 3.0 or MIT's X Window System (X11R4 or X11R5), and IBM PC or compatible computers running Microsoft Windows 3.1 or later.
Cryogenic scanning tunneling microscope with a magnetic coarse approach
NASA Astrophysics Data System (ADS)
Davydov, D. N.; Deltour, R.; Horii, N.; Timofeev, V. A.; Grokholski, A. S.
1993-11-01
A compact, rigid, and reliable cryogenic scanning tunneling microscope (CSTM) with a vertical electromagnetic coarse approach system was developed. This device can be used for topographic and local tunneling spectroscopy studies at liquid nitrogen and helium temperatures. Minimal step sizes of 28 nm for the electromagnetic translation device were achieved. The additional possibility of a coarse approach operation in the inertial slip-stick mode, without electromagnets, was successfully tested, making this STM compatible with external magnetic fields. A simple technique for characterizing the STM rigidity has been developed. Preliminary data, taken with this instrument are presented, demonstrating the achievement, at liquid helium temperature, of atomic resolution for topographic studies, and also the possibility of measuring simultaneously superconducting energy gap spectra.
Grant, James; Kenney, Mitchell; Shah, Yash D; Escorcia-Carranza, Ivonne; Cumming, David R S
2018-04-16
We experimentally demonstrate a CMOS compatible medium wave infrared metal-insulator-metal (MIM) metamaterial absorber structure where for a single dielectric spacer thickness at least 93% absorption is attained for 10 separate bands centred at 3.08, 3.30, 3.53, 3.78, 4.14, 4.40, 4.72, 4.94, 5.33, 5.60 μm. Previous hyperspectral MIM metamaterial absorber designs required that the thickness of the dielectric spacer layer be adjusted in order to attain selective unity absorption across the band of interest thereby increasing complexity and cost. We show that the absorption characteristics of the hyperspectral metamaterial structures are polarization insensitive and invariant for oblique incident angles up to 25° making them suitable for practical implementation in an imaging system. Finally, we also reveal that under TM illumination and at certain oblique incident angles there is an extremely narrowband Fano resonance (Q > 50) between the MIM absorber mode and the surface plasmon polariton mode that could have applications in hazardous/toxic gas identification and biosensing.
Automation of electromagnetic compatability (EMC) test facilities
NASA Technical Reports Server (NTRS)
Harrison, C. A.
1986-01-01
Efforts to automate electromagnetic compatibility (EMC) test facilities at Marshall Space Flight Center are discussed. The present facility is used to accomplish a battery of nine standard tests (with limited variations) deigned to certify EMC of Shuttle payload equipment. Prior to this project, some EMC tests were partially automated, but others were performed manually. Software was developed to integrate all testing by means of a desk-top computer-controller. Near real-time data reduction and onboard graphics capabilities permit immediate assessment of test results. Provisions for disk storage of test data permit computer production of the test engineer's certification report. Software flexibility permits variation in the tests procedure, the ability to examine more closely those frequency bands which indicate compatibility problems, and the capability to incorporate additional test procedures.
NASA Astrophysics Data System (ADS)
Mekanik, F.; Imteaz, M. A.; Gato-Trinidad, S.; Elmahdi, A.
2013-10-01
In this study, the application of Artificial Neural Networks (ANN) and Multiple regression analysis (MR) to forecast long-term seasonal spring rainfall in Victoria, Australia was investigated using lagged El Nino Southern Oscillation (ENSO) and Indian Ocean Dipole (IOD) as potential predictors. The use of dual (combined lagged ENSO-IOD) input sets for calibrating and validating ANN and MR Models is proposed to investigate the simultaneous effect of past values of these two major climate modes on long-term spring rainfall prediction. The MR models that did not violate the limits of statistical significance and multicollinearity were selected for future spring rainfall forecast. The ANN was developed in the form of multilayer perceptron using Levenberg-Marquardt algorithm. Both MR and ANN modelling were assessed statistically using mean square error (MSE), mean absolute error (MAE), Pearson correlation (r) and Willmott index of agreement (d). The developed MR and ANN models were tested on out-of-sample test sets; the MR models showed very poor generalisation ability for east Victoria with correlation coefficients of -0.99 to -0.90 compared to ANN with correlation coefficients of 0.42-0.93; ANN models also showed better generalisation ability for central and west Victoria with correlation coefficients of 0.68-0.85 and 0.58-0.97 respectively. The ability of multiple regression models to forecast out-of-sample sets is compatible with ANN for Daylesford in central Victoria and Kaniva in west Victoria (r = 0.92 and 0.67 respectively). The errors of the testing sets for ANN models are generally lower compared to multiple regression models. The statistical analysis suggest the potential of ANN over MR models for rainfall forecasting using large scale climate modes.
Loguercio, Alessandro D; Muñoz, Miguel Angel; Luque-Martinez, Issis; Hass, Viviane; Reis, Alessandra; Perdigão, Jorge
2015-09-01
To evaluate the effect of adhesion strategy on the enamel microshear bond strengths (μSBS), etching pattern, and in situ degree of conversion (DC) of seven universal adhesives. 84 extracted third molars were sectioned in four parts (buccal, lingual, proximal) and divided into 21 groups, according to the combination of the main factors adhesive (AdheSE Universal [ADU], All-Bond Universal [ABU], Clearfil Universal [CFU], Futurabond U [FBU], G-Bond Plus [GBP], Prime&Bond Elect (PBE), and Scotchbond Universal Adhesive [SBU]), and adhesion strategy (etch-and-rinse, active self-etch, and passive self-etch). Specimens were stored in water (37°C/24h) and tested at 1.0mm/min (μSBS). Enamel-resin interfaces were evaluated for DC using micro-Raman spectroscopy. The enamel-etching pattern was evaluated under a field-emission scanning electron microscope (direct and replica techniques). Data were analyzed with two-way ANOVA and Tukey's test (α=0.05). Active self-etch application increased μSBS and DC for five out of the seven universal adhesives when compared to passive application (p<0.001). A deeper enamel-etching pattern was observed for all universal adhesives in the etch-and-rinse strategy. A slight improvement in etching ability was observed in active self-etch application compared to that of passive self-etch application. Replicas of GBP and PBE applied in active self-etch mode displayed morphological features compatible with water droplets. The DC of GBP and PBE were not affected by the application/strategy mode. In light of the improved performance of universal adhesives when applied actively in SE mode, selective enamel etching with phosphoric acid may not be crucial for their adhesion to enamel. The active application of universal adhesives in self-etch mode may be a practical alternative to enamel etching in specific clinical situations. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
2009-01-01
This Interim Standard establishes requirements for evaluation, testing, and selection of materials that are intended for use in space vehicles, associated Ground Support Equipment (GSE), and facilities used during assembly, test, and flight operations. Included are requirements, criteria, and test methods for evaluating the flammability, offgassing, and compatibility of materials.
NASA Astrophysics Data System (ADS)
Yang, Tian; He, Xiaolong; Zhou, Xin; Lei, Zeyu; Wang, Yalin; Yang, Jie; Cai, De; Chen, Sung-Liang; Wang, Xueding
2018-05-01
Integrating surface plasmon resonance (SPR) devices upon single-mode fiber (SMF) end facets renders label-free sensing systems that have a simple dip-and-read configuration, a small form factor, high compatibility with fiber-optic techniques, and invasive testing capability. Such devices are not only low cost replacement of current equipments in centralized laboratories, but also highly desirable for opening paths to new applications of label-free optical sensing technologies, such as point-of-care immunological tests and intravascular ultrasound imaging. In this paper, we explain the requirements and challenges for such devices from the perspectives of biomolecule and ultrasound detection applications. In such a context, we review our recent work on SMF end-facet SPR cavities. This include a glue-and-strip fabrication method to transfer a nano-patterned thin gold film to the SMF end-facet with high yield, high quality and high alignment precision, the designs of distributed Bragg reflector (DBR) and distributed feedback (DFB) SPR cavities that couple efficiently with the SMF guided mode and reach quality factors of over 100, and the preliminary results for biomolecule interaction sensing and ultrasound detection. The particular advantages and potential values of these devices have been discussed, in terms of sensitivity, data reliability, reproducibility, bandwidth, etc.
High-temperature compatibility study of iridium (DOP-26 alloy) with graphite and plutonia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Axler, K.M.; Eash, D.T.
1987-12-01
This report outlines the materials compatibility tests conducted on DOP-26 iridium alloy and carbon. The carbon used was in the form of woven graphite as present in the impact shell used to encase plutonia in nuclear heat sources. In addition, compatibility tests of the DOP-26 alloy with plutonia are described. The reactivity observed in both systems is discussed. 4 refs., 6 figs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Colldelram, Carles, E-mail: ccolldelram@cells.es; Nicolas, Josep, E-mail: jnicolas@cells.es; Nikitina, Liudmila, E-mail: lnikitina@cells.es
In this work we report the design and performance of a novel compact in-vacuum actuator, designed to be compatible with all the motions required for the scissor-type ESRF mirror bender. These mirror benders include several linear actuators, which drive the mirror bending torques, as well as the main alignment motions such as pitch and translation along the normal to the mirror surface. The motions are provided by compact linear actuators, which consist of motor, reduction, spindle and nut, encapsulated on a closed air volume to provide vacuum compatibility. The actuator includes a hydroformed bellows to transmit the force to themore » actuator tip, and an electrical feedthrough for the motor cables. The design boundaries for these actuators are quite tight, as they must be integrated in a narrow volume, must be UHV compatible and must provide high resolution, for a relatively high load. As a result, they have limited mechanical performance, and in some cases poor reliability. To overcome these problems, we designed and implemented a different concept. In the proposed concept, the motor rotation is converted onto a linear motion by means of a cam instead of a spindle and a nut. This allows for much shorter and stiffer transmission system, with similar dimensions. The vacuum compatibility is intrinsic for this solution, since the whole mechanism of the actuator is UHV compatible. All motions are preloaded and guided by vacuum compatible (hybrid metal-ceramics) ball bearings. This allows the system reaching a repeatability and backlash well within the micron. The absence of friction allows for a high reliability and releases the maintenance needs of the system. The transmission is intrinsically irreversible, and the system can hold a load of 250 N within a few nanometers without any holding current on the motors. This allows the system to move reliably also in micro-stepping mode, providing a resolution well below the half-step nominal resolution of 100 nm. Performances have been tested on a prototype. We report the results of the tests obtained in air and in vacuum after bake-out. Two units of the new actuator have been installed at the photoemission beamline of ALBA (CIRCE) and are routinely used to align the 3 µm spot on the field of view of the Photoemission Electron Microscope. The absence of any noticeable backlash, or any friction effect and the reliability of the micro-stepping motion has simplified very much the alignment of the photon beam, reducing the alignment process to few minutes. The excellent performances and relatively high load capacity of this new compact actuator make of it a versatile element to be integrated in other systems requiring reliable in-vacuum positioning.« less
Transient analysis mode participation for modal survey target mode selection using MSC/NASTRAN DMAP
NASA Technical Reports Server (NTRS)
Barnett, Alan R.; Ibrahim, Omar M.; Sullivan, Timothy L.; Goodnight, Thomas W.
1994-01-01
Many methods have been developed to aid analysts in identifying component modes which contribute significantly to component responses. These modes, typically targeted for dynamic model correlation via a modal survey, are known as target modes. Most methods used to identify target modes are based on component global dynamic behavior. It is sometimes unclear if these methods identify all modes contributing to responses important to the analyst. These responses are usually those in areas of hardware design concerns. One method used to check the completeness of target mode sets and identify modes contributing significantly to important component responses is mode participation. With this method, the participation of component modes in dynamic responses is quantified. Those modes which have high participation are likely modal survey target modes. Mode participation is most beneficial when it is used with responses from analyses simulating actual flight events. For spacecraft, these responses are generated via a structural dynamic coupled loads analysis. Using MSC/NASTRAN DMAP, a method has been developed for calculating mode participation based on transient coupled loads analysis results. The algorithm has been implemented to be compatible with an existing coupled loads methodology and has been used successfully to develop a set of modal survey target modes.
Experimental Interactions of Components of Hemodialysis Units with Human Blood
Zucker, W. H.; Shinoda, B. A.; Mason, R. G.
1974-01-01
An in vitro model test system for estimation of the blood compatibility of hemodialysis membranes and tubing is described. The model test system consists of a modified hemodialysis unit and blood pump through which fresh citrated human blood is circulated. The effects of the use of different pump and tubing types upon hematologic and blood coagulation parameters are described. Preexposure of test surfaces to albumin appeared to enhance blood compatibility characteristics of the model test system, whereas preexposure to a high density lipoprotein preparation or a proteinpolysaccharide preparation was without appreciable benefit. Use of blood from subjects receiving aspirin resulted in enhanced blood compatibility in the test system as did use of heparin. Use of Warfarin or dextran did not appear to enhance blood compatibility of test surfaces under the conditions of this test system. Dialysis membranes and tubing which formed parts of the test system were examined by scanning and transmission electron microscopy in control tests and in tests for effects of proteins and antithrombotic agents. ImagesFig 5Fig 6Fig 7Fig 8Fig 9Fig 10Fig 11Fig 12Fig 13Fig 14Fig 1Fig 2Fig 3Fig 4 PMID:4825611
Efficient spot size converter for higher-order mode fiber-chip coupling.
Lai, Yaxiao; Yu, Yu; Fu, Songnian; Xu, Jing; Shum, Perry Ping; Zhang, Xinliang
2017-09-15
We propose and demonstrate a silicon-based spot size converter (SSC), composed of two identical tapered channel waveguides and a Y-junction. The SSC is designed for first-order mode fiber-to-chip coupling on the basis of mode petal separation and the recombination method. Compared with a traditional on-chip SSC, this method is superior with reduced coupling loss when dealing with a higher-order mode. To the best of our knowledge, we present the first experimental observations of a higher-order SSC which is fully compatible with a standard fabrication process. Average coupling losses of 3 and 5.5 dB are predicted by simulation and demonstrated experimentally. A fully covered 3 dB bandwidth over a 1515-1585 nm wavelength range is experimentally observed.
On-chip switch for reconfigurable mode-multiplexing optical network.
Sun, Chunlei; Yu, Yu; Chen, Guanyu; Zhang, Xinliang
2016-09-19
The switching and routing is essential for an advanced and reconfigurable optical network, and great efforts have been done for traditional single-mode system. We propose and demonstrate an on-chip switch compatible with mode-division multiplexing system. By controlling the induced phase difference, the functionalities of dynamically routing data channels can be achieved. The proposed switch is experimentally demonstrated with low insertion loss of ~1 dB and high extinction ratio of ~20 dB over the C-band for OFF-ON switchover. For further demonstration, the non-return-to-zero on-off keying signals at 10 Gb/s carried on the two spatial modes are successfully processed. Open and clear eye diagrams can be observed and the bit error rate measurements indicate a good data routing performance.
Blade Vibration Measurement System
NASA Technical Reports Server (NTRS)
Platt, Michael J.
2014-01-01
The Phase I project successfully demonstrated that an advanced noncontacting stress measurement system (NSMS) could improve classification of blade vibration response in terms of mistuning and closely spaced modes. The Phase II work confirmed the microwave sensor design process, modified the sensor so it is compatible as an upgrade to existing NSMS, and improved and finalized the NSMS software. The result will be stand-alone radar/tip timing radar signal conditioning for current conventional NSMS users (as an upgrade) and new users. The hybrid system will use frequency data and relative mode vibration levels from the radar sensor to provide substantially superior capabilities over current blade-vibration measurement technology. This frequency data, coupled with a reduced number of tip timing probes, will result in a system capable of detecting complex blade vibrations that would confound traditional NSMS systems. The hardware and software package was validated on a compressor rig at Mechanical Solutions, Inc. (MSI). Finally, the hybrid radar/tip timing NSMS software package and associated sensor hardware will be installed for use in the NASA Glenn spin pit test facility.
Channel electron multiplier compatibility with Viton and Apiezon-L vacuum grease
NASA Astrophysics Data System (ADS)
McComas, D. J.; Baldonado, J. R.; Bame, S. J.; Barraclough, B. L.
1987-12-01
Clean Viton and Viton coated with Apiezon-L vacuum grease were tested for their noncontaminating compatibility with channel electron multipliers (CEMs). The test setup and procedure were the same as those used previously in conjunction with CEM compatibility tests of certain epoxies, solder, and fluorocarbon polymer materials useful for construction of spaceflight sensors. While some CEM gain degradation was noted during exposure to Viton and Apiezon-L, the present tests indicate that, at least over instrument lifetimes of about 2 x 10 to the 12th counts, these materials should be suitable for (1) preflight space sensor testing systems, (2) hermetic seals for CEM-based space sensors, and (3) terrestrial CEM-based instrumentation.
Compatibility testing of spacecraft materials and space-storable liquid propellants
NASA Technical Reports Server (NTRS)
Constantino, L. L.; Denson, J. R.; Krishnan, C. S.; Toy, A.
1974-01-01
Compatibility measurements were made for aluminum 2219-T87 alloy and titanium 6Al-4V alloy in the presence of liquid fluorine and flox. Results of post test characterization after exposure durations of 61 and 70 weeks are presented. Results of the total test program are analyzed.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-16
... Toxicology Testing. Labeling (dose limits). Electromagnetic incompatibility........ Electromagnetic... analysis and nonclinical testing must validate electromagnetic compatibility performance, wireless... electromagnetic compatibility performance, wireless performance, and electrical safety; and (4) Labeling must...
NASA Astrophysics Data System (ADS)
Cicek, Paul-Vahe; Elsayed, Mohannad; Nabki, Frederic; El-Gamal, Mourad
2017-11-01
An above-IC compatible multi-level MEMS surface microfabrication technology based on a silicon carbide structural layer is presented. The fabrication process flow provides optimal electrostatic transduction by allowing the creation of independently controlled submicron vertical and lateral gaps without the need for high resolution lithography. Adopting silicon carbide as the structural material, the technology ensures material, chemical and thermal compatibility with modern semiconductor nodes, reporting the lowest peak processing temperature (i.e. 200 °C) of all comparable works. This makes this process ideally suited for integrating capacitive-based MEMS directly above standard CMOS substrates. Process flow design and optimization are presented in the context of bulk-mode disk resonators, devices that are shown to exhibit improved performance with respect to previous generation flexural beam resonators, and that represent relatively complex MEMS structures. The impact of impending improvements to the fabrication technology is discussed.
TESL Reporter, Vol. 10, No. 3.
ERIC Educational Resources Information Center
Pack, Alice C., Ed.
This issue of a publication devoted to providing ideas and guidance for teachers of English as a second language includes the following articles and features: (1) "Toward Interactive Modes in Guided Composition," (2) "Computer Compatibility in the Classroom," (3) "Discourse Structure in Reading," (4) "Terminal Behavior and Language," (5) "Sector…
Anderson, Collin; Boehme, Sabrina; Ouellette, Jacquelyn; Stidham, Chanelle; MacKay, Mark
2014-01-01
Purpose: The physical and chemical compatibility of intravenous acetaminophen with commonly administered injectable medications was evaluated. Methods: Simulated Y-site evaluation was accomplished by mixing 2 mL of acetaminophen (10 mg/mL) with 2 mL of an alternative intravenous medication and subsequently storing the mixture in a polypropylene syringe for 4 hours. The aliquot solutions were visually inspected and evaluated for crystal content at 4 hours by infusing 4 mL of the medication mixture through a 0.45-μm nitrocellulose filter disc. Medication mixtures that were selected for chemical stability testing were analyzed by high-performance liquid chromatography at 0, 1, and 4 hours using a Zorbax Eclipse Plus C18, 4.6 x 100 mm, 3.5-μm column for separation of analytes with subsequent diode-array detection. Medications were considered chemically compatible if the concentrations of all components were >90% of the original concentrations during the 4 hour simulated Y-site compatibility test. Results: U.S. Pharmacopeial Convention (USP) standards for physical particle counts were met for acetaminophen injection (10 mg/mL) when combined with cefoxitin, ceftriaxone, clindamycin, dexamethasone, diphenhydramine, dolasetron, fentanyl, granisetron, hydrocortisone, hydromorphone, ketorolac, meperidine, methylprednisolone, midazolam, morphine, nalbuphine, ondansetron, piperacillin/tazobactam, ranitidine, and vancomycin. Injectable acetaminophen is incompatible with acyclovir and diazepam and therefore should not be administered concomitantly with either of these products. Further testing confirmed the chemical compatibility of acetaminophen with ceftriaxone, diphenhydramine, granisetron, ketorolac, nalbuphine, ondansetron, piperacillin/tazobactam, and vancomycin. Conclusion: All medications tested with acetaminophen were physically compatible except for acyclovir and diazepam. All 8 medications tested for chemical compatibility with acetaminophen were stable over the 4 hour simulated Y-site administration study. PMID:24421562
Loncke, Filip T; Campbell, Jamie; England, Amanda M; Haley, Tanya
2006-02-15
Message generating is a complex process involving a number of processes, including the selection of modes to use. When expressing a message, human communicators typically use a combination of modes. This phenomenon is often termed multimodality. This article explores the use of models that explain multimodality as an explanatory framework for augmentative and alternative communication (AAC). Multimodality is analysed from a communication, psycholinguistic, and cognitive perspective. Theoretical and applied topics within AAC can be explained or described within the multimodality framework considering iconicity, simultaneous communication, lexical organization, and compatibility of communication modes. Consideration of multimodality is critical to understanding underlying processes in individuals who use AAC and individuals who interact with them.
Copper nanorod array assisted silicon waveguide polarization beam splitter
Kim, Sangsik; Qi, Minghao
2014-01-01
We present the design of a three-dimensional (3D) polarization beam splitter (PBS) with a copper nanorod array placed between two silicon waveguides. The localized surface plasmon resonance (LSPR) of a metal nanorod array selectively cross-couples transverse electric (TE) mode to the coupler waveguide, while transverse magnetic (TM) mode passes through the original input waveguide without coupling. An ultra-compact and broadband PBS compared to all-dielectric devices is achieved with the LSPR. The output ports of waveguides are designed to support either TM or TE mode only to enhance the extinction ratios. Compared to silver, copper is fully compatible with complementary metal-oxide-semiconductor (CMOS) technology. PMID:24787839
Buckling of circular cylindrical shells under dynamically applied axial loads
NASA Technical Reports Server (NTRS)
Tulk, J. D.
1972-01-01
A theoretical and experimental study was made of the buckling characteristics of perfect and imperfect circular cylindrical shells subjected to dynamic axial loading. Experimental data included dynamic buckling loads (124 data points), high speed photographs of buckling mode shapes and observations of the dynamic stability of shells subjected to rapidly applied sub-critical loads. A mathematical model was developed to describe the dynamic behavior of perfect and imperfect shells. This model was based on the Donnell-Von Karman compatibility and equilibrium equations and had a wall deflection function incorporating five separate modes of deflection. Close agreement between theory and experiment was found for both dynamic buckling strength and buckling mode shapes.
Moving base simulation of an ASTOVL lift-fan aircraft
NASA Technical Reports Server (NTRS)
Chung, William W. Y.; Borchers, Paul F.; Franklin, James A.
1995-01-01
Using a generalized simulation model, a moving-base simulation of a lift-fan short takeoff/vertical landing fighter aircraft was conducted on the Vertical Motion Simulator at Ames Research Center. Objectives of the experiment were to (1) assess the effects of lift-fan propulsion system design features on aircraft control during transition and vertical flight including integration of lift fan/lift/cruise engine/aerodynamic controls and lift fan/lift/cruise engine dynamic response, (2) evaluate pilot-vehicle interface with the control system and head-up display including control modes for low-speed operational tasks and control mode/display integration, and (3) conduct operational evaluations of this configuration during takeoff, transition, and landing similar to those carried out previously by the Ames team for the mixed-flow, vectored thrust, and augmentor-ejector concepts. Based on results of the simulation, preliminary assessments of acceptable and borderline lift-fan and lift/cruise engine thrust response characteristics were obtained. Maximum pitch, roll, and yaw control power used during transition, hover, and vertical landing were documented. Control and display mode options were assessed for their compatibility with a range of land-based and shipboard operations from takeoff to cruise through transition back to hover and vertical landing. Flying qualities were established for candidate control modes and displays for instrument approaches and vertical landings aboard an LPH assault ship and DD-963 destroyer. Test pilot and engineer teams from the Naval Air Warfare Center, Boeing, Lockheed, McDonnell Douglas, and the British Defence Research Agency participated in the program.
Customized binary and multi-level HfO2-x-based memristors tuned by oxidation conditions.
He, Weifan; Sun, Huajun; Zhou, Yaxiong; Lu, Ke; Xue, Kanhao; Miao, Xiangshui
2017-08-30
The memristor is a promising candidate for the next generation non-volatile memory, especially based on HfO 2-x , given its compatibility with advanced CMOS technologies. Although various resistive transitions were reported independently, customized binary and multi-level memristors in unified HfO 2-x material have not been studied. Here we report Pt/HfO 2-x /Ti memristors with double memristive modes, forming-free and low operation voltage, which were tuned by oxidation conditions of HfO 2-x films. As O/Hf ratios of HfO 2-x films increase, the forming voltages, SET voltages, and R off /R on windows increase regularly while their resistive transitions undergo from gradually to sharply in I/V sweep. Two memristors with typical resistive transitions were studied to customize binary and multi-level memristive modes, respectively. For binary mode, high-speed switching with 10 3 pulses (10 ns) and retention test at 85 °C (>10 4 s) were achieved. For multi-level mode, the 12-levels stable resistance states were confirmed by ongoing multi-window switching (ranging from 10 ns to 1 μs and completing 10 cycles of each pulse). Our customized binary and multi-level HfO 2-x -based memristors show high-speed switching, multi-level storage and excellent stability, which can be separately applied to logic computing and neuromorphic computing, further suitable for in-memory computing chip when deposition atmosphere may be fine-tuned.
NASA Technical Reports Server (NTRS)
Hirsch, David; Johnson, Harry
1994-01-01
The NASA Lewis Research Center requested NASA Johnson Space Center White Sands Test Facility to conduct flammability, odor, offgassing, thermal vacuum stability, and compatibility tests with aerospace fluids of several wire insulations.
Inflation in a Scale Invariant Universe
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ferreira, Pedro G.; Hill, Christopher T.; Noller, Johannes
A scale-invariant universe can have a period of accelerated expansion at early times: inflation. We use a frame-invariant approach to calculate inflationary observables in a scale invariant theory of gravity involving two scalar fields - the spectral indices, the tensor to scalar ratio, the level of isocurvature modes and non-Gaussianity. We show that scale symmetry leads to an exact cancellation of isocurvature modes and that, in the scale-symmetry broken phase, this theory is well described by a single scalar field theory. We find the predictions of this theory strongly compatible with current observations.
Phason thermal transport of three-helix state in insulating chiral magnets
NASA Astrophysics Data System (ADS)
Tatara, Gen
2018-06-01
Thermal dynamics of the three-helix state in a chiral magnet is studied based on a phason representation. Although phason representation is convenient for intuitive description, it is not straightforwardly compatible with microscopic linear response calculation of transport phenomena, because it is a (semi)macroscopic picture obtained by a coarse graining. By separating the slow phason mode and fast magnon mode, we show that phason thermal dynamics is driven by thermal magnon flow via the spin-transfer effect. The magnon and phason velocities are calculated by use of thermal vector potential formalism.
NASA Technical Reports Server (NTRS)
Harrison, Cecil A.
1986-01-01
The efforts to automate the electromagentic compatibility (EMC) test facilites at Marshall Flight Center were examined. A battery of nine standard tests is to be integrated by means of a desktop computer-controller in order to provide near real-time data assessment, store the data acquired during testing on flexible disk, and provide computer production of the certification report.
Oxygen Compatibility Testing of Composite Materials
NASA Technical Reports Server (NTRS)
Graf, Neil A.; Hudgins, Richard J.; McBain, Michael
2000-01-01
The development of polymer composite liquid oxygen LO2 tanks is a critical step in creating the next generation of launch vehicles. Future launch vehicles need to minimize the gross liftoff weight (GLOW), which is possible due to the 25%-40% reduction in weight that composite materials could provide over current aluminum technology. Although a composite LO2 tank makes these weight savings feasible, composite materials have not historically been viewed as "LO2 compatible." To be considered LO2 compatible, materials must be selected that will resist any type of detrimental, combustible reaction when exposed to usage environments. This is traditionally evaluated using a standard set of tests. However, materials that do not pass the standard tests can be shown to be safe for a particular application. This paper documents the approach and results of a joint NASA/Lockheed Martin program to select and verify LO2 compatible composite materials for liquid oxygen fuel tanks. The test approach developed included tests such as mechanical impact, particle impact, puncture, electrostatic discharge, friction, and pyrotechnic shock. These tests showed that composite liquid oxygen tanks are indeed feasible for future launch vehicles.
NASA Astrophysics Data System (ADS)
Verma, Payal; Juneja, Sucheta; Savelyev, Dmitry A.; Khonina, Svetlana N.; Gopal, Ram
2016-04-01
This paper presents design and fabrication of a 1-DOF (degree-of-freedom) drive mode and 2-DOF sense mode micro-gyroscope. It is an inherently robust structure and offers a high sense frequency bandwidth. The proposed design utilizes resonance of the1-DOF drive mode oscillator and employs dynamic amplification concept in sense modes to increase the sensitivity while maintaining robustness. The 2-DOF in the sense direction renders the device immune to process imperfections and environmental effects. The design is simulated using FEA software (CoventorWare®). The device is designed considering process compatibility with SU-8 based UV-LIGA process, which is an economical fabrication technique. The complete fabrication process is presented along with SEM images of the fabricated device. The device has 9 µm thick Nickel as the key structural layer with an overall reduced key structure size of 2.2 mm by 2.1 mm.
A back-illuminated megapixel CMOS image sensor
NASA Technical Reports Server (NTRS)
Pain, Bedabrata; Cunningham, Thomas; Nikzad, Shouleh; Hoenk, Michael; Jones, Todd; Wrigley, Chris; Hancock, Bruce
2005-01-01
In this paper, we present the test and characterization results for a back-illuminated megapixel CMOS imager. The imager pixel consists of a standard junction photodiode coupled to a three transistor-per-pixel switched source-follower readout [1]. The imager also consists of integrated timing and control and bias generation circuits, and provides analog output. The analog column-scan circuits were implemented in such a way that the imager could be configured to run in off-chip correlated double-sampling (CDS) mode. The imager was originally designed for normal front-illuminated operation, and was fabricated in a commercially available 0.5 pn triple-metal CMOS-imager compatible process. For backside illumination, the imager was thinned by etching away the substrate was etched away in a post-fabrication processing step.
NASA Technical Reports Server (NTRS)
Perry, J. C.
1975-01-01
A series of electromagnetic compatibility (EMC) tests were conducted in May, 1975 in the Soviet Union. The purpose of the EMC tests was to determine the effects of the operating environment of the Soviet aircraft, Soyuz, upon the electrical performance of the USA's cable communications equipment located in Soyuz. The test procedures necessary to check out the cable communications test configuration in preparation for the EMC tests are presented.
78 FR 35173 - Physical Medicine Devices; Reclassification of Stair-Climbing Wheelchairs
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-12
.... Electromagnetic interference: The device may interfere with the operation of other electrical devices or be... electromagnetic compatibility testing as well as characterization of speed/acceleration, battery longevity, and... electrical safety and electromagnetic compatibility of the device. Performance testing must demonstrate...
InfoQUEST: An Online Catalog for Small Libraries.
ERIC Educational Resources Information Center
Campbell, Bonnie
1984-01-01
InfoQUEST is a microcomputer-based online public access catalog, designed for the small library handling file sizes up to 25,000 records. Based on the IBM-PC, or compatible machines, the system will accept downloading, in batch mode, of records from the library's file on the UTLAS Catalog Support System. (Author/EJS)
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-12
... add to the SC deliverables Change 1 to DO-224C ``Singal-in-Space Minimum Aviation System Performance Standards (MASPS) for Advanced VHF Digital Data Communications Including Compatibility with Digital Voice... Performance Standards (MOPS) for Aircraft VDL Mode 2 Physical Link and Network Layer'' Other Business Adjourn...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-10
... basic safety and essential performance--Collateral standard: Electromagnetic compatibility--Requirements... standard: Electromagnetic compatibility--Requirements and tests 5-34 5-53 IEC 60601-1-2 Third edition 2007... for basic safety and essential performance--Collateral standard: Electromagnetic compatibility...
An in vitro investigation into the physical properties of irreversible hydrocolloid alternatives.
Patel, Rishi D; Kattadiyil, Mathew T; Goodacre, Charles J; Winer, Myron S
2010-11-01
A number of manufacturers have introduced new products that are marketed as alternatives to irreversible hydrocolloid impression materials. However, there is a paucity of laboratory and clinical research on these products compared to traditional irreversible hydrocolloid. The purpose of this study was to evaluate the detail reproduction, gypsum compatibility, and linear dimensional change of 3 recently introduced impression materials designed as alternatives to irreversible hydrocolloid. The tested materials were Position Penta Quick, Silgimix, and AlgiNot. An irreversible hydrocolloid impression material, Jeltrate Plus Antimicrobial, served as the control. The parameters of detail reproduction, gypsum compatibility, and linear dimensional change were tested in accordance with ANSI/ADA Specifications No. 18 and 19. The gypsum compatibility was tested using a type III stone (Microstone Golden) and a type IV stone (Die-Keen Green). The data were analyzed using the Kruskal-Wallis rank test and the Mann-Whitney U test (α=.05). The test materials demonstrated significantly (P<.001) better detail reproduction than the control material. Silgimix exhibited the best compatibility with Microstone, whereas AlgiNot and Position Penta Quick exhibited the best gypsum compatibility with Die-Keen. An incompatibility was observed over time between the Jeltrate control material and the Microstone gypsum material. For linear dimensional change, the mean dimension of the control material most closely approximated the distance between the lines on the test die, but it exhibited the greatest variability in measurements. All of the test materials exhibited linear dimensional change within the ADA's accepted limit of 1.0%. The 3 new impression materials exhibited better detail reproduction and less variability in linear dimensional change than the irreversible hydrocolloid control. Gypsum compatibility varied with the brand of gypsum used, with an incompatibility identified between the control material (Jeltrate Plus Antimicrobial) and Microstone related to surface changes observed over time. Copyright © 2010 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.
Zhu, Long; Wang, Andong; Chen, Shi; Liu, Jun; Mo, Qi; Du, Cheng; Wang, Jian
2017-10-16
Twisted light carrying orbital angular momentum (OAM) is a special kind of structured light that has a helical phase front, a phase singularity, and a doughnut intensity profile. Beyond widespread developments in manipulation, microscopy, metrology, astronomy, nonlinear and quantum optics, OAM-carrying twisted light has seen emerging application of optical communications in free space and specially designed fibers. Instead of specialty fibers, here we show the direct use of a conventional graded-index multi-mode fiber (MMF) for OAM communications. By exploiting fiber-compatible mode exciting and filtering elements, we excite the first four OAM mode groups in an MMF. We demonstrate 2.6-km MMF transmission using four data-carrying OAM mode groups (OAM 0,1 , OAM +1,1 /OAM -1,1 , OAM +2,1 , OAM +3,1 ). Moreover, we demonstrate two data-carrying OAM mode groups multiplexing transmission over the 2.6-km MMF with low-level crosstalk free of multiple-input multiple-output digital signal processing (MIMO-DSP). The demonstrations may open up new perspectives to fiber-based OAM communication/non-communication applications using already existing conventional fibers.
Effects of the thermal sterilization procedure on polymeric products
NASA Technical Reports Server (NTRS)
Campbell, B. A.; Kalfayan, S. H.
1971-01-01
Properties of samples are tested, after thermal exposure, and values are compared with unexposed samples. Thermal stability or compatibility ratings of formulated or compounded organic polymers using trade names are made and degree of change in measured properties is assessed. Products are rated compatible, marginal, or not compatible.
Soukhanovskii, V. A.; Allen, S. L.; Fenstermacher, M. E.; ...
2016-11-16
Experimental results from the National Spherical Torus Experiment (NSTX), a medium-size spherical tokamak with a compact divertor, and DIII-D, a large conventional aspect ratio tokamak, demonstrate that the snowflake (SF) divertor configuration may provide a promising solution for mitigating divertor heat loads and target plate erosion compatible with core H-mode confinement in the future fusion devices, where the standard radiative divertor solution may be inadequate. In NSTX, where the initial high-power SF experiment was performed, the SF divertor was compatible with H-mode confinement, and led to the destabilization of large Edge Localized Modes (ELMs). However, a stable partial detachment ofmore » the outer strike point was also achieved where inter-ELM peak heat flux was reduced by factors 3-5, and peak ELM heat flux was reduced by up to 80% (see standard divertor). The DIII-D studies show the SF divertor enables significant power spreading in attached and radiative divertor conditions. Results include: compatibility with the core and pedestal, peak inter-ELM divertor heat flux reduction due to geometry at lower ne, and ELM energy and divertor peak heat flux reduction, especially prominent in radiative D 2-seeded SF divertor, and nearly complete power detachment and broader radiated power distribution in the radiative D 2-seeded SF divertor at PSOL = 3 - 4 MW. A variety of SF configurations can be supported by the divertor coil set in NSTX Upgrade. Edge transport modeling with the multifluid edge transport code UEDGE shows that the radiative SF divertor can successfully reduce peak divertor heat flux for the projected PSOL ≃ 9 MW case. Furthermore, the radiative SF divertor with carbon impurity provides a wider ne operating window, 50% less argon is needed in the impurity-seeded SF configuration to achieve similar q peak reduction factors (see standard divertor).« less
Jia, Hao; Zhou, Ting; Zhang, Lei; Ding, Jianfeng; Fu, Xin; Yang, Lin
2017-08-21
We propose a 2 × 2 multimode optical switch, which is composed of two mode de-multiplexers, n 2 × 2 single-mode optical switches where n is the number of the supported spatial modes, and two mode multiplexers. As a proof of concept, asymmetric directional couplers are employed to construct the mode multiplexers and de-multiplexers, balanced Mach-Zehnder interferometer is utilized to construct the 2 × 2 single-mode optical switches. The fabricated silicon 2 × 2 multimode optical switch has a broad optical bandwidth and can support four spatial modes. The link-crosstalk for all four modes is smaller than -18.8 dB. The inter-mode crosstalk for the same optical link is less than -22.1 dB. 40 Gbps data transmission is performed for all spatial modes and all optical links. The power penalties for the error-free switching (BER<10 -9 ) at 25 Gbps are less than 1.8 dB for all channels at the wavelength of 1550 nm. The power consumption of the device is 117.9 mW in the "cross" state and 116.2 mW in the "bar" state. The switching time is about 21 μs. This work enables large-capacity multimode photonic networks-on-chip.
Materials Compatibility Testing in RSRM ODC: Free Cleaner Selection
NASA Technical Reports Server (NTRS)
Keen, Jill M.; Sagers, Neil W.; McCool, Alex (Technical Monitor)
2001-01-01
Government regulations have mandated production phase-outs of a number of solvents, including 1,1,1-trichloroethane, an ozone-depleting chemical (ODC). This solvent was used extensively in the production of the Reusable Solid Rocket Motors (RSRMs) for the Space Shuttle. Many tests have been performed to identify replacement cleaners. One major area of concern in the selection of a new cleaner has been compatibility. Some specific areas considered included cleaner compatibility with non-metallic surfaces, painted surfaces, support materials such as gloves and wipers as well as corrosive properties of the cleaners on the alloys used on these motors. The intent of this paper is to summarize the test logic, methodology, and results acquired from testing the many cleaner and material combinations.
Electromagnetic Compatibility Design of the Computer Circuits
NASA Astrophysics Data System (ADS)
Zitai, Hong
2018-02-01
Computers and the Internet have gradually penetrated into every aspect of people’s daily work. But with the improvement of electronic equipment as well as electrical system, the electromagnetic environment becomes much more complex. Electromagnetic interference has become an important factor to hinder the normal operation of electronic equipment. In order to analyse the computer circuit compatible with the electromagnetic compatibility, this paper starts from the computer electromagnetic and the conception of electromagnetic compatibility. And then, through the analysis of the main circuit and system of computer electromagnetic compatibility problems, we can design the computer circuits in term of electromagnetic compatibility. Finally, the basic contents and methods of EMC test are expounded in order to ensure the electromagnetic compatibility of equipment.
Wideband fiber optic communications link
NASA Astrophysics Data System (ADS)
Bray, J. R.
1984-12-01
This thesis examined the feasibility of upgrading a nine port fiber optic bundle telecommunications system to a single strand fiber optic system. Usable pieces of equipment were identified and new Light Emitting Diodes (LED), Photodetectors and single strand SMA styled fiber optic connectors were ordered. Background research was conducted in the area of fiber optic power launching, fiber losses, connector losses and efficiencies. A new modulation/demodulation circuit was designed and constructed using parts from unused equipment. A new front panel was constructed to house the components, switches and connectors. A 2-m piece of optical fiber was terminated with the new connectors and tested for connector loss, numeric aperture and attenuation. The new LED was characterized by its emission radiation pattern and the entire system was tested for functional operation, frequency response and bandwidth of operation. An operations manual was prepared to ensure proper use in the future. The result was a two piece, single strand, fiber optic communications systems fully TTL compatible, capable of transmitting digital signals from 80 Kbit/sec to 20 Mbit/sec. The system was tested in a half duplex mode using both baseband and carrier modulated signals.
NEXT Ion Thruster Performance Dispersion Analyses
NASA Technical Reports Server (NTRS)
Soulas, George C.; Patterson, Michael J.
2008-01-01
The NEXT ion thruster is a low specific mass, high performance thruster with a nominal throttling range of 0.5 to 7 kW. Numerous engineering model and one prototype model thrusters have been manufactured and tested. Of significant importance to propulsion system performance is thruster-to-thruster performance dispersions. This type of information can provide a bandwidth of expected performance variations both on a thruster and a component level. Knowledge of these dispersions can be used to more conservatively predict thruster service life capability and thruster performance for mission planning, facilitate future thruster performance comparisons, and verify power processor capabilities are compatible with the thruster design. This study compiles the test results of five engineering model thrusters and one flight-like thruster to determine unit-to-unit dispersions in thruster performance. Component level performance dispersion analyses will include discharge chamber voltages, currents, and losses; accelerator currents, electron backstreaming limits, and perveance limits; and neutralizer keeper and coupling voltages and the spot-to-plume mode transition flow rates. Thruster level performance dispersion analyses will include thrust efficiency.
Feasibility study for removing calcified material using a planar rectangular ultrasound transducer.
Damianou, Christakis; Couppis, Andreas
2016-01-01
The aim of the proposed study was to conduct a feasibility study using a flat rectangular (3 mm × 10 mm) MRI compatible transducer operating at 5.3 MHz for destroying calcified material in an in vitro model. The proposed method can be used in the future for treating atherosclerosis plaques of the coronary, carotid or peripheral arteries. The system was tested initially on calcium rods. Another test was performed in a hydroxyapatite-polylactide model. A parametric study was performed where the mass of calcified material removed was studied as a function of intensity, pulse repetition frequency (PRF), duty factor (DF) and presence of bubbles. The amount of calcified material removed is directly related to the intensity, PRF and DF. It was found that the presence of bubbles accelerates the removal of calcified material. In order to ensure that pure mechanical mode ultrasound was used, the protocols were designed so that the temperature does not exceed 1 °C.
Perceptual video quality comparison of 3DTV broadcasting using multimode service systems
NASA Astrophysics Data System (ADS)
Ok, Jiheon; Lee, Chulhee
2015-05-01
Multimode service (MMS) systems allow broadcasters to provide multichannel services using a single HD channel. Using these systems, it is possible to provide 3DTV programs that can be watched either in three-dimensional (3-D) or two-dimensional (2-D) modes with backward compatibility. In the MMS system for 3DTV broadcasting using the Advanced Television Systems Committee standards, the left and the right views are encoded using MPEG-2 and H.264, respectively, and then transmitted using a dual HD streaming format. The left view, encoded using MPEG-2, assures 2-D backward compatibility while the right view, encoded using H.264, can be optionally combined with the left view to generate stereoscopic 3-D views. We analyze 2-D and 3-D perceptual quality when using the MMS system by comparing items in the frame-compatible format (top-bottom), which is a conventional transmission scheme for 3-D broadcasting. We performed perceptual 2-D and 3-D video quality evaluation assuming 3DTV programs are encoded using the MMS system and top-bottom format. The results show that MMS systems can be preferable with regard to perceptual 2-D and 3-D quality and backward compatibility.
Flexible and unique representations of two-digit decimals.
Zhang, Li; Chen, Min; Lin, Chongde; Szűcs, Denes
2014-09-01
We examined the representation of two-digit decimals through studying distance and compatibility effects in magnitude comparison tasks in four experiments. Using number pairs with different leftmost digits, we found both the second digit distance effect and compatibility effect with two-digit integers but only the second digit distance effect with two-digit pure decimals. This suggests that both integers and pure decimals are processed in a compositional manner. In contrast, neither the second digit distance effect nor the compatibility effect was observed in two-digit mixed decimals, thereby showing no evidence for compositional processing of two-digit mixed decimals. However, when the relevance of the rightmost digit processing was increased by adding some decimals pairs with the same leftmost digits, both pure and mixed decimals produced the compatibility effect. Overall, results suggest that the processing of decimals is flexible and depends on the relevance of unique digit positions. This processing mode is different from integer analysis in that two-digit mixed decimals demonstrate parallel compositional processing only when the rightmost digit is relevant. Findings suggest that people probably do not represent decimals by simply ignoring the decimal point and converting them to natural numbers. Copyright © 2014 Elsevier B.V. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-04
... for Safety--Collateral Standard: Electromagnetic Compatibility--Requirements and Tests,'' and ASME A18.1 ``Safety Standard for Platform Lifts and Stairway Chair Lifts'') must validate electromagnetic...: Electromagnetic Compatibility--Requirements and Tests,'' and ASME A18.1 ``Safety Standard for Platform Lifts and...
NASA Astrophysics Data System (ADS)
Hoskins, Douglas; Snead, Robert
1988-05-01
This report details the results of an electromagnetic compatibility test on the SCI Systems Data Acquisition and Control Assembly (DACA). This assembly is an electronic processor which controls the central communication link from the Tethered Satellite System (TSS) to the Space Transportation System Orbiter Space Shuttle.
Two-Dimensional Edge Detection by Guided Mode Resonant Metasurface
NASA Astrophysics Data System (ADS)
Saba, Amirhossein; Tavakol, Mohammad Reza; Karimi-Khoozani, Parisa; Khavasi, Amin
2018-05-01
In this letter, a new approach to perform edge detection is presented using an all-dielectric CMOS-compatible metasurface. The design is based on guided-mode resonance which provides a high quality factor resonance to make the edge detection experimentally realizable. The proposed structure that is easy to fabricate, can be exploited for detection of edges in two dimensions due to its symmetry. Also, the trade-off between gain and resolution of edge detection is discussed which can be adjusted by appropriate design parameters. The proposed edge detector has also the potential to be used in ultrafast analog computing and image processing.
Being While Doing: An Inductive Model of Mindfulness at Work.
Lyddy, Christopher J; Good, Darren J
2016-01-01
Mindfulness at work has drawn growing interest as empirical evidence increasingly supports its positive workplace impacts. Yet theory also suggests that mindfulness is a cognitive mode of "Being" that may be incompatible with the cognitive mode of "Doing" that undergirds workplace functioning. Therefore, mindfulness at work has been theorized as "being while doing," but little is known regarding how people experience these two modes in combination, nor the influences or outcomes of this interaction. Drawing on a sample of 39 semi-structured interviews, this study explores how professionals experience being mindful at work. The relationship between Being and Doing modes demonstrated changing compatibility across individuals and experience, with two basic types of experiences and three types of transitions. We labeled experiences when informants were unable to activate Being mode while engaging Doing mode as Entanglement, and those when informants reported simultaneous co-activation of Being and Doing modes as Disentanglement. This combination was a valuable resource for offsetting important limitations of the typical reliance on the Doing cognitive mode. Overall our results have yielded an inductive model of mindfulness at work, with the core experience, outcomes, and antecedent factors unified into one system that may inform future research and practice.
Heck, Martijn J R; Bente, Erwin A J M; Smalbrugge, Barry; Oei, Yok-Siang; Smit, Meint K; Anantathanasarn, Sanguan; Nötzel, Richard
2007-12-10
First observation of passive mode-locking in two-section quantum-dot lasers operating at wavelengths around 1.55 mum is reported. Pulse generation at 4.6 GHz from a 9 mm long device is verified by background-free autocorrelation, RF-spectra and real-time oscilloscope traces. The output pulses are stretched in time and heavily up-chirped with a value of 20 ps/nm, contrary to what is normally observed in passively mode-locked semiconductor lasers. The complete output spectrum is shown to be coherent over 10 nm. From a 7 mm long device Q-switching is observed over a large operating regime. The lasers have been realized using a fabrication technology that is compatible with further photonic integration. This makes the laser a promising candidate for e.g. a mode-comb generator in a complex photonic chip.
Integrated amorphous silicon-aluminum long-range surface plasmon polariton (LR-SPP) waveguides
NASA Astrophysics Data System (ADS)
Sturlesi, Boaz; Grajower, Meir; Mazurski, Noa; Levy, Uriel
2018-03-01
We demonstrate the design, fabrication, and experimental characterization of a long range surface plasmon polariton waveguide that is compatible with complementary metal-oxide semiconductor backend technology. The structure consists of a thin aluminum strip embedded in amorphous silicon. This configuration offers a symmetric environment in which surface plasmon polariton modes undergo minimal loss. Furthermore, the plasmonic mode profile matches the modes of the dielectric (amorphous silicon) waveguide, thus allowing efficient coupling between silicon photonics and plasmonic platforms. The propagation length of the plasmonic waveguide was measured to be about 27 μm at the telecom wavelength around 1550 nm, in good agreement with numerical simulations. As such, the waveguide features both tight mode confinement and decent propagation length. On top of its photonic properties, placing a metal within the structure may also allow for additional functionalities such as photo-detection, thermo-optic tuning, and electro-optic control to be implemented.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Rate of Permeation in Plastic Packaging and Receptacles B Appendix B to Part 173 Transportation Other..., App. B Appendix B to Part 173—Procedure for Testing Chemical Compatibility and Rate of Permeation in... °C. (64 °F.) b. Test Method 2: 28 days at a temperature no lower than 50 °C. (122 °F.) c. Test Method...
Demonstration of a stable ultrafast laser based on a nonlinear microcavity
Peccianti, M.; Pasquazi, A.; Park, Y.; Little, B.E.; Chu, S.T.; Moss, D.J.; Morandotti, R.
2012-01-01
Ultrashort pulsed lasers, operating through the phenomenon of mode-locking, have had a significant role in many facets of our society for 50 years, for example, in the way we exchange information, measure and diagnose diseases, process materials, and in many other applications. Recently, high-quality resonators have been exploited to demonstrate optical combs. The ability to phase-lock their modes would allow mode-locked lasers to benefit from their high optical spectral quality, helping to realize novel sources such as precision optical clocks for applications in metrology, telecommunication, microchip-computing, and many other areas. Here we demonstrate the first mode-locked laser based on a microcavity resonator. It operates via a new mode-locking method, which we term filter-driven four-wave mixing, and is based on a CMOS-compatible high quality factor microring resonator. It achieves stable self-starting oscillation with negligible amplitude noise at ultrahigh repetition rates, and spectral linewidths well below 130 kHz. PMID:22473009
Final Report Advanced Quasioptical Launcher System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jeffrey Neilson
2010-04-30
This program developed an analytical design tool for designing antenna and mirror systems to convert whispering gallery RF modes to Gaussian or HE11 modes. Whispering gallery modes are generated by gyrotrons used for electron cyclotron heating of fusion plasmas in tokamaks. These modes cannot be easily transmitted and must be converted to free space or waveguide modes compatible with transmission line systems.This program improved the capability of SURF3D/LOT, which was initially developed in a previous SBIR program. This suite of codes revolutionized quasi-optical launcher design, and this code, or equivalent codes, are now used worldwide. This program added functionality tomore » SURF3D/LOT to allow creating of more compact launcher and mirror systems and provide direct coupling to corrugated waveguide within the vacuum envelope of the gyrotron. Analysis was also extended to include full-wave analysis of mirror transmission line systems. The code includes a graphical user interface and is available for advanced design of launcher systems.« less
Practical Reason within and across Disciplinary Borders: A Response to Longhofer and Floersch
ERIC Educational Resources Information Center
Kemp, Susan P.; Nurius, Paula S.
2014-01-01
Longhofer and Floersch argue for more expansive thinking about the modes of social science research predominant in contemporary social work science. This commentary concurs with aspects of their article that we see as compatible both with social work aims and with current trends and imperatives in research and practice, including mixed methods and…
47 CFR 61.22 - Composition of tariffs.
Code of Federal Regulations, 2011 CFR
2011-10-01
.../2 inch (8.89 cm) diskette, or a 5 inch CD-ROM, formatted in an IBM-compatible form using either Word... tariff. The diskette or CD-ROM must be submitted in “read only” mode. The diskette or CD-ROM must be... multiple diskettes or CD-ROMs are submitted, the issuing carrier shall clearly label each diskette in the...
NASA Astrophysics Data System (ADS)
Wang, Qichao; Wang, Jiachun; Zhao, Dapeng; Zhang, Jikui; Li, Zhigang; Chen, Zongsheng; Zeng, Jie; Miao, Lei; Shi, Jiaming
2016-11-01
We propose a new method to disclose the camouflaged targets coated with far infrared/CO2 laser stealth-compatible coating by utilizing terahertz (THz) radar. A coating based on one-dimensional photonic crystal (1DPC) with a defect mode is specially designed and successfully prepared, which possesses a high reflectivity in 8-14 μm waveband and a low reflectivity at 10.6 μm, by alternating thin films of Ge, ZnSe and Si. The propagation characteristic of 0.3-2 THz wave at incident angle from 0° to 80° in such PC coating is investigated theoretically based on characteristic matrix method. The maximal transmittance is up to 92%, and the absorptivity keeps lower than 0.5% over the whole band. The results are verified by experiments, which demonstrate the feasibility of using THz radar to detect the targets covered with such stealth-compatible coatings.
Wang, Ting; Su, Yingjuan; Li, Yuan
2012-01-01
Essentially all ferns can perform both sexual and asexual reproduction. Their populations represent suitable study objects to test the population genetic effects of different reproductive systems. Using the diploid homosporous fern Alsophila spinulosa as an example species, the main purpose of this study was to assess the relative impact of sexual and asexual reproduction on the level and structure of population genetic variation. Inter-simple sequence repeats analysis was conducted on 140 individuals collected from seven populations (HSG, LCH, BPC, MPG, GX, LD, and ZHG) in China. Seventy-four polymorphic bands discriminated a total of 127 multilocus genotypes. Character compatibility analysis revealed that 50.0 to 70.0% of the genotypes had to be deleted in order to obtain a tree-like structure in the data set from populations HSG, LCH, MPG, BPC, GX, and LD; and there was a gradual decrease of conflict in the data set when genotypes with the highest incompatibility counts were successively deleted. In contrast, in population ZHG, only 33.3% of genotypes had to be removed to achieve complete compatibility in the data set, which showed a sharp decline in incompatibility upon the deletion of those genotypes. All populations examined possessed similar levels of genetic variation. Population ZHG was not found to be more differentiated than the other populations. Sexual recombination is the predominant source of genetic variation in most of the examined populations of A. spinulosa. However, somatic mutation contributes most to the genetic variation in population ZHG. This change of the primary mode of reproduction does not cause a significant difference in the population genetic composition. Character compatibility analysis represents an effective approach to separate the role of sexual and asexual components in shaping the genetic pattern of fern populations.
Power Electronics for a Miniaturized Arcjet
NASA Technical Reports Server (NTRS)
Pinero, Luis R.; Bowers, Glen E.
1997-01-01
A 0.3 kW Power Processing Unit (PPU) was designed, tested on resistive loads, and then integrated with a miniaturized arcjet. The main goal of the design was to minimize size and mass while maintaining reasonable efficiency. In order to obtain the desired reductions in mass, simple topologies and control methods were considered. The PPU design incorporates a 50 kHz, current-mode-control, pulse-width-modulated (PWM), push-pull topology. An input voltage of 28 +/- 4V was chosen for compatibility with typical unregulated low voltage busses anticipated for smallsats. An efficiency of 0.90 under nominal operating conditions was obtained. The component mass of the PPU was 0.475 kg and could be improved by optimization of the output filter design. The estimated mass for a flight PPU based on this design is less than a kilogram.
NASA Technical Reports Server (NTRS)
Harper, Susan A.; Juarez, Alfredo; Peralta, Stephen F.; Stoltzfus, Joel; Arpin, Christina Pina; Beeson, Harold D.
2016-01-01
Solvents used to clean oxygen system components must be assessed for oxygen compatibility, as incompatible residue or fluid inadvertently left behind within an oxygen system can pose a flammability risk. The most recent approach focused on solvent ignition susceptibility to assess the flammability risk associated with these materials. Previous evaluations included Ambient Pressure Liquid Oxygen (LOX) Mechanical Impact Testing (ASTM G86) and Autogenous Ignition Temperature (AIT) Testing (ASTM G72). The goal in this approach was to identify a solvent material that was not flammable in oxygen. As environmental policies restrict the available options of acceptable solvents, it has proven difficult to identify one that is not flammable in oxygen. A more rigorous oxygen compatibility approach is needed in an effort to select a new solvent for NASA applications. NASA White Sands Test Facility proposed an approach that acknowledges oxygen flammability, yet selects solvent materials based on their relative oxygen compatibility ranking, similar to that described in ASTM G63-99. Solvents are selected based on their ranking with respect to minimal ignition susceptibility, damage and propagation potential, as well as their relative ranking when compared with other solvent materials that are successfully used in oxygen systems. Test methods used in this approach included ASTM G86 (Ambient Pressure LOX Mechanical Impact Testing and Pressurized Gaseous Oxygen (GOX) Mechanical Impact Testing), ASTM G72 (AIT Testing), and ASTM D240 (Heat of Combustion (HOC) Testing). Only four solvents were tested through the full battery of tests for evaluation of oxygen compatibility: AK-225G as a baseline comparison, Solstice PF, L-14780, and Vertrel MCA. Baseline solvent AK-225G exhibited the lowest HOC and highest AIT of solvents tested. Nonetheless, Solstice PF, L-14780, and Vertrel MCA HOCs all fell well within the range of properties that are associated with proven oxygen system materials. Tested AITs for these solvents fell only slightly lower than the AIT for the proven AK-225G solvent. Based on these comparisons in which solvents exhibited properties within those ranges seen with proven oxygen system materials, it is believed that Solstice PF, L-14780, and Vertrel MCA would perform well with respect to oxygen compatibility.
ERIC Educational Resources Information Center
Chang, J. C.; And Others
1986-01-01
Discusses a new program at the University of Michigan in hazardous waste management. Describes a laboratory demonstration that deals with the reactivity and potential violence of several reactions that may be encountered on a hazardous waste site. Provides criteria for selecting particular compatibility testing methods. (TW)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pennington, J.C.; Theriot, E.A.
1983-06-01
A formulation of the fungus Cercospora rodmanii Conway has been produced, as a biocontrol of waterhyacinth (Eichhornia crassipes (Mart.) Solms.). To ensure the most efficient germination of the formulation, 12 potential enhancing agents were tested for addition during the spray application. The agents were aspartic acid, glucose, glutamic acid, gum xanthan, nutrient agar, Ortho X-77 Spreader, Tween 20, Tween 60, Tween 80, sodium alginate, Super Slupper, and yeast extract. Compatibility of test agents and combinations of test agents with two lots of the formulation was determined in the laboratory. All combinations of test agents were compatible with both lots ofmore » the C. rodmanii formulation. The C. rodmanii formulation was sprayed with test agents on waterhyacinth pseudolaminae. Damage was monitored each week for 8 weeks by assigning a disease index to each original and new pseudolaminae. No spots having characteristics suggestive of C. rodmanii infection were observed at any time during the study. Lack of infectivity could be remedied by isolating a virulent strain of C. rodmanii from the field. Agents determined to be compatible in this study could then be reexamined for enhancing infectivity on a virulent C. rodmanii formulation. 14 references, 2 figures, 5 tables.« less
Bacterial Compatibility in Combined Inoculations Enhances the Growth of Potato Seedlings.
Santiago, Christine D; Yagi, Shogo; Ijima, Motoaki; Nashimoto, Tomoya; Sawada, Maki; Ikeda, Seishi; Asano, Kenji; Orikasa, Yoshitake; Ohwada, Takuji
2017-03-31
The compatibility of strains is crucial for formulating bioinoculants that promote plant growth. We herein assessed the compatibility of four potential bioinoculants isolated from potato roots and tubers (Sphingomonas sp. T168, Streptomyces sp. R170, Streptomyces sp. R181, and Methylibium sp. R182) that were co-inoculated in order to improve plant growth. We screened these strains using biochemical tests, and the results obtained showed that R170 had the highest potential as a bioinoculant, as indicated by its significant ability to produce plant growth-promoting substances, its higher tolerance against NaCl (2%) and AlCl 3 (0.01%), and growth in a wider range of pH values (5.0-10.0) than the other three strains. Therefore, the compatibility of R170 with other strains was tested in combined inoculations, and the results showed that the co-inoculation of R170 with T168 or R182 synergistically increased plant weight over un-inoculated controls, indicating the compatibility of strains based on the increased production of plant growth promoters such as indole-3-acetic acid (IAA) and siderophores as well as co-localization on roots. However, a parallel test using strain R181, which is the same Streptomyces genus as R170, showed incompatibility with T168 and R182, as revealed by weaker plant growth promotion and a lack of co-localization. Collectively, our results suggest that compatibility among bacterial inoculants is important for efficient plant growth promotion, and that R170 has potential as a useful bioinoculant, particularly in combined inoculations that contain compatible bacteria.
Fu, Xiaoran; Apgar, James R.; Keating, Amy E.
2007-01-01
Computational protein design can be used to select sequences that are compatible with a fixed-backbone template. This strategy has been used in numerous instances to engineer novel proteins. However, the fixed-backbone assumption severely restricts the sequence space that is accessible via design. For challenging problems, such as the design of functional proteins, this may not be acceptable. In this paper, we present a method for introducing backbone flexibility into protein design calculations and apply it to the design of diverse helical BH3 ligands that bind to the anti-apoptotic protein Bcl-xL, a member of the Bcl-2 protein family. We demonstrate how normal mode analysis can be used to sample different BH3 backbones, and show that this leads to a larger and more diverse set of low-energy solutions than can be achieved using a native high-resolution Bcl-xL complex crystal structure as a template. We tested several of the designed solutions experimentally and found that this approach worked well when normal mode calculations were used to deform a native BH3 helix structure, but less well when they were used to deform an idealized helix. A subsequent round of design and testing identified a likely source of the problem as inadequate sampling of the helix pitch. In all, we tested seventeen designed BH3 peptide sequences, including several point mutants. Of these, eight bound well to Bcl-xL and four others showed weak but detectable binding. The successful designs showed a diversity of sequences that would have been difficult or impossible to achieve using only a fixed backbone. Thus, introducing backbone flexibility via normal mode analysis effectively broadened the set of sequences identified by computational design, and provided insight into positions important for binding Bcl-xL. PMID:17597151
Ballistic mode Mercury orbiter missions.
NASA Technical Reports Server (NTRS)
Hollenbeck, G. R.
1973-01-01
The MVM'73 Mercury flyby mission will initiate exploration of this unique planet. No firm plans for follow-on investigations have materialized due to the difficult performance requirements of the next logical step, an orbiter mission. Previous investigations of ballistic mode flight opportunities have indicated requirements for a Saturn V class launch vehicle. Consequently, most recent effort has been oriented to use of solar electric propulsion. More comprehensive study of the ballistic flight mode utilizing Venus gravity-assist has resulted in identification of timely high-performance mission opportunities compatible with programmed launch vehicles and conventional spacecraft propulsion technologies. A likely candidate for an initial orbiter mission is a 1980 opportunity which offers net orbiter spacecraft mass of about 435 kg with the Titan IIIE/Centaur launch vehicle and single stage solid propulsion for orbit insertion.
Polarization modulation based on the hybrid waveguide of graphene sandwiched structure
NASA Astrophysics Data System (ADS)
Yang, Junbo; Chen, Dingbo; Zhang, Jingjing; Zhang, Zhaojian; Huang, Jie
2017-09-01
Polarization beam splitter (PBS) plays an important role to realize beam control and modulation. A novel hybrid structure of graphene sandwiched waveguide is proposed to fulfill polarization manipulation and selection based on the refractive index engineering techniques. The fundamental mode of TM cannot be supported in this case. However, both TE and TM mode are excited and transmitting in the hybrid waveguide if the design parameters, including the waveguide width and the waveguide height, are changed. The incident wavelength largely affects the effective index, which results in supporting/not supporting the TM mode. The proposed design exhibits high extinction ratio, compact in size, flexible to control, compatible with CMOS process, and easy to be integrated with other optoelectronic devices, allowing it to be used in optical communication and optical information processing.
Amorphous SiC/c-ZnO-Based Quasi-Lamb Mode Sensor for Liquid Environments.
Caliendo, Cinzia; Hamidullah, Muhammad; Laidoudi, Farouk
2017-05-25
The propagation of the quasi-Lamb modes along a-SiC/ZnO thin composite plates was modeled and analysed with the aim to design a sensor able to detect the changes in parameters of a liquid environment, such as added mass and viscosity changes. The modes propagation was modeled by numerically solving the system of coupled electro-mechanical field equations in three media. The mode shape, the power flow, the phase velocity, and the electroacoustic coupling efficiency (K²) of the modes were calculated, specifically addressing the design of enhanced-coupling, microwave frequency sensors for applications in probing the solid/liquid interface. Three modes were identified that have predominant longitudinal polarization, high phase velocity, and quite good K²: the fundamental quasi symmetric mode (qS₀) and two higher order quasi-longitudinal modes (qL₁ and qL₂) with a dominantly longitudinal displacement component in one plate side. The velocity and attenuation of these modes were calculated for different liquid viscosities and added mass, and the gravimetric and viscosity sensitivities of both the phase velocity and attenuation were theoretically calculated. The present study highlights the feasibility of the a-SiC/ZnO acoustic waveguides for the development of high-frequency, integrated-circuit compatible electroacoustic devices suitable for working in a liquid environment.
GEOSTEP: A gravitation experiment in Earth-orbiting satellite to test the Equivalence Principle
NASA Astrophysics Data System (ADS)
Bonneville, R.
2003-10-01
Testing the Equivalence Principle has been recognized by the scientific community as a short-term prime objective for fundamental physics in space. In 1994, a Phase 0/A study of the GEOSTEP mission has been initiated by CNES in order to design a space experiment to test the Equivalence Principle to an accuracy of 10 -17, with the constraint to be compatible with the small versatile platform PROTEUS under study. The GEOSTEP payload comprises a set of four differential accelerometers placed at cryogenic temperature on board a drag-free, 3-axis stabilized satellite in low-Earth orbit. Each accelerometer contains a pair of test masses A-A, A-B, A-C, B-C (inner mass - outer mass) made of three different materials A, B, C with decreasing densities. The accelerometer concept is the fully electrostatic levitation and read-out device proposed by ONERA, called SAGE (Space Accelerometer for Gravitation Experiment). The drag-free and attitude control system (DFACS) is monitored by the common-mode data of the accelerometers along their three axes, while the possible violation signal is detected by the differential-mode data along the longitudinal sensitive axis. The cryostat is a single chamber supercritical Helium dewar designed by CEA. Helium boiling off from the dewar feeds a set of proportional gas thrusters performing the DFACS. Error analysis and data processing preparation is managed by OCA/CERGA. The satellite will be on a 6 am - 6 pm near-polar, near-circular, Sun-synchronous orbit, at an altitude of 600 to 900 km, depending on the atmospheric density at the time of launch. GEOSTEP could be launched in 2002; the nominal mission duration is at least four months.
Automated JPSS VIIRS GEO code change testing by using Chain Run Scripts
NASA Astrophysics Data System (ADS)
Chen, W.; Wang, W.; Zhao, Q.; Das, B.; Mikles, V. J.; Sprietzer, K.; Tsidulko, M.; Zhao, Y.; Dharmawardane, V.; Wolf, W.
2015-12-01
The Joint Polar Satellite System (JPSS) is the next generation polar-orbiting operational environmental satellite system. The first satellite in the JPSS series of satellites, J-1, is scheduled to launch in early 2017. J1 will carry similar versions of the instruments that are on board of Suomi National Polar-Orbiting Partnership (S-NPP) satellite which was launched on October 28, 2011. The center for Satellite Applications and Research Algorithm Integration Team (STAR AIT) uses the Algorithm Development Library (ADL) to run S-NPP and pre-J1 algorithms in a development and test mode. The ADL is an offline test system developed by Raytheon to mimic the operational system while enabling a development environment for plug and play algorithms. The Perl Chain Run Scripts have been developed by STAR AIT to automate the staging and processing of multiple JPSS Sensor Data Record (SDR) and Environmental Data Record (EDR) products. JPSS J1 VIIRS Day Night Band (DNB) has anomalous non-linear response at high scan angles based on prelaunch testing. The flight project has proposed multiple mitigation options through onboard aggregation, and the Option 21 has been suggested by the VIIRS SDR team as the baseline aggregation mode. VIIRS GEOlocation (GEO) code analysis results show that J1 DNB GEO product cannot be generated correctly without the software update. The modified code will support both Op21, Op21/26 and is backward compatible with SNPP. J1 GEO code change version 0 delivery package is under development for the current change request. In this presentation, we will discuss how to use the Chain Run Script to verify the code change and Lookup Tables (LUTs) update in ADL Block2.
NASA Astrophysics Data System (ADS)
Latimer, T. W.; Rinehart, G. H.
1992-05-01
This report covers progress on the Milliwatt Generator Project from April 1986 through March 1988. Activities included fuel processing and characterization, production of heat sources, fabrication of pressure-burst test units, compatibility studies, impact testing, and examination of surveillance units. The major task of the Los Alamos Milliwatt Generator Project is to fabricate MC2893A heat sources (4.0 W) for MC2730A radioisotope thermoelectric generators (RTG's) and MC3599 heat sources (4.5 W) for MC3500 RTG's. The MWG Project interfaces with the following contractors: Sandia National Laboratories, Albuquerque (designer); E.I. du Pont de Nemours and Co. (Inc.), Savannah River Plant (fuel); Monsanto Research Corporation, Mound Facility (metal hardware); and General Electric Company, Neutron Devices Department (RTG's). In addition to MWG fabrication activities, Los Alamos is involved in (1) fabrication of pressure-burst test units, (2) compatibility testing and evaluation, (3) examination of surveillance units, and (4) impact testing and subsequent examination of compatibility and surveillance units.
Auction-based bandwidth allocation in the Internet
NASA Astrophysics Data System (ADS)
Wei, Jiaolong; Zhang, Chi
2002-07-01
It has been widely accepted that auctioning which is the pricing approach with minimal information requirement is a proper tool to manage scare network resources. Previous works focus on Vickrey auction which is incentive compatible in classic auction theory. In the beginning of this paper, the faults of the most representative auction-based mechanisms are discussed. And then a new method called uniform-price auction (UPA), which has the simplest auction rule is proposed and it's incentive compatibility in the network environment is also proved. Finally, the basic mode is extended to support applications which require minimum bandwidth guarantees for a given time period by introducing derivative market, and a market mechanism for network resource allocation which is predictable, riskless, and simple for end-users is completed.
Mossotti, Victor G.; Eldeeb, A. Raouf; Oscarson, Robert
1998-01-01
MORPH-I is a set of C-language computer programs for the IBM PC and compatible minicomputers. The programs in MORPH-I are used for the fractal analysis of scanning electron microscope and electron microprobe images of pore profiles exposed in cross-section. The program isolates and traces the cross-sectional profiles of exposed pores and computes the Richardson fractal dimension for each pore. Other programs in the set provide for image calibration, display, and statistical analysis of the computed dimensions for highly complex porous materials. Requirements: IBM PC or compatible; minimum 640 K RAM; mathcoprocessor; SVGA graphics board providing mode 103 display.
Compatibility tests of materials for a lithium-cooled space power reactor concept
NASA Technical Reports Server (NTRS)
Sinclair, J. H.
1973-01-01
Materials for a lithium-cooled space power reactor concept must be chemically compatible for up to 50,000 hr at high temperature. Capsule tests at 1040 C (1900 F) were made of material combinations of prime interest: T-111 in direct contact with uranium mononitride (UN), Un in vacuum separated from T-111 by tungsten wire, UN with various oxygen impurity levels enclosed in tungsten wire lithium-filled T-111 capsules, and TZM and lithium together in T-111 capsules. All combinations were compatible for over 2800 hr except for T-111 in direct contact with UN.
JTIDS electromagnetic compatibility in the 960-1215 MHz band
NASA Astrophysics Data System (ADS)
Lokuta, Robert S.
1992-01-01
The Joint Tactical Information Distribution System (JTIDS) operates in the 960-1215 MHz frequency band. This band is allocated world-wide on a primary basis for aeronautical radio navigation. JTIDS was designed to be electromagnetically compatible with the Air Traffic Control systems that operate in this band. Over the past 15 years, extensive bench tests, flight tests, and analyses were conducted to assess the electromagnetic compatibility (EMC) of JTIDS in the 960-1215 MHz band. This report summarizes the results and conclusions of these efforts, presents some supporting data and provides specific guidance for the operation of JTIDS within the National Air Space. Guidance and recommendations are also provided to assist in the definition and scope of a JTIDS EMC test and analysis effort.
47 CFR 73.9003 - Compliance requirements for covered demodulator products: Unscreened content.
Code of Federal Regulations, 2010 CFR
2010-10-01
... operating in a mode compatible with the digital visual interface (DVI) rev. 1.0 Specification as an image having the visual equivalent of no more than 350,000 pixels per frame (e.g. an image with resolution of 720×480 pixels for a 4:3 (nonsquare pixel) aspect ratio), and 30 frames per second. Such an image may...
USDA-ARS?s Scientific Manuscript database
Two opposing evolutionary constraints exert pressure on pathogens: one to diversify virulence factors in order to evade host defenses, and the other to retain virulence factors critical for maintaining a compatible interaction. To better understand how the diversified arsenals of fungal genes promot...
Hybrid CMS methods with model reduction for assembly of structures
NASA Technical Reports Server (NTRS)
Farhat, Charbel
1991-01-01
Future on-orbit structures will be designed and built in several stages, each with specific control requirements. Therefore there must be a methodology which can predict the dynamic characteristics of the assembled structure, based on the dynamic characteristics of the subassemblies and their interfaces. The methodology developed by CSC to address this issue is Hybrid Component Mode Synthesis (HCMS). HCMS distinguishes itself from standard component mode synthesis algorithms in the following features: (1) it does not require the subcomponents to have displacement compatible models, which makes it ideal for analyzing the deployment of heterogeneous flexible multibody systems, (2) it incorporates a second-level model reduction scheme at the interface, which makes it much faster than other algorithms and therefore suitable for control purposes, and (3) it does answer specific questions such as 'how does the global fundamental frequency vary if I change the physical parameters of substructure k by a specified amount?'. Because it is based on an energy principle rather than displacement compatibility, this methodology can also help the designer to define an assembly process. Current and future efforts are devoted to applying the HCMS method to design and analyze docking and berthing procedures in orbital construction.
Electrochemical Test Method for Evaluating Long-Term Propellant-Material Compatibility
1978-12-01
matrix of test conditions is illustrated in Fig. 13. A statistically designed test matrix (Graeco-Latin Cube) could not be used because of passivation...ears simulated time results in a findl decomposition level of 0.753 mg/cm The data was examined using statistical techniqves to evaluate the relative...metals. The compatibility of all nine metals was evaluated in hydrazine containing water and chloride. The results of the statistical analy(is
Analytical formulation of orbiter-payload models coupled by trunnion joints with Coulomb friction
NASA Technical Reports Server (NTRS)
Liu, Frank C.
1987-01-01
An orbiter and its payload substructure are linked together by five trunnion joints which have thirty degrees-of-freedom. Geometric compatibility conditions require fourteen of the interface physical coordinates of the orbiter and payload to be equal to each other and the remaining sixteen are free to have relative motions under Coulomb friction. The component modes synthesis method using fourteen inertia relief attachment modes for the formulation of the coupled system is presented. The exact nonlinear friction function is derived based on the characteristics of the joints. Formulation is applicable to an orbiter that carries any number of payload substructures.
Analytical formulation of orbiter-payload coupled by trunnion joints with Coulomb friction
NASA Technical Reports Server (NTRS)
Liu, Frank C.
1986-01-01
An orbiter and its payload substructure are linked together by five trunnion joints which have thirty degrees-of-freedom. Geometric compatibility conditions require fourteen of the interface physical coordinates of the orbiter and payload to be equal to each other and the remaining sixteen are free to have relative motions under Coulomb friction. The component modes synthesis method using fourteen inertia relief attachment modes for the formulation of the coupled system is presented. The exact nonlinear friction function is derived based on the characteristics of the joints. Formulation is applicable to an orbiter that carries any number of payload substructures.
A Dual-Mode Microwave Applicator for Liver Tumor Thermotherapy
NASA Astrophysics Data System (ADS)
Reimann, Carolin; Schüßler, Martin; Jakoby, Rolf; Bazrafshan, Babak; Hübner, Frank; Vogl, Thomas
2018-03-01
The concept of a novel dual-mode microwave applicator for diagnosis and thermal ablation treatment of tumorous tissue is presented in this paper. This approach is realized by integrating a planar resonator array to, firstly, detect abnormalities by a relative dielectric analysis, and secondly, perform a highly localized thermal ablation. A further essential advantage is addressed by designing the applicator to be MRI compatible to provide a multimodal imaging procedure. Investigations for an appropriate frequency range lead to the use of much higher operating frequencies between 5 GHz and 10 GHz, providing a significantly lower power consumption for microwave ablation of only 20 W compared to commercial available applicators.
Comparative serological investigation between cat and tiger blood for transfusion
THENGCHAISRI, Naris; SINTHUSINGHA, Chayakrit; ARTHITWONG, Surapong; SATTASATHUCHANA, Panpicha
2017-01-01
Evidence suggests that non-domesticated felids inherited the same AB-erythrocyte antigens as domestic cats. To study the possible compatibility of tiger blood with that of other endangered felidae, blood samples from captive tigers and domestic cats were subjected to an in vitro study. The objectives of this study were to (1) identify whether the captive tigers had blood type AB and (2) determine the compatibility between the blood of captive tigers and that of domestic cats with a similar blood type. The anti-coagulated blood with ethylenediaminetetraacetic acid of 30 tigers was examined to determine blood type, and a crossmatching test was performed between tiger and cat blood. All 30 tigers had blood type A. Tube agglutination tests using tiger plasma with cat erythrocytes resulted in 100% agglutination (n=30) with type B cat erythrocytes and 76.7% agglutination (n=23) with type A cat erythrocytes. The 80% of major and 60% of minor compatibilities between blood from 10 tigers and 10 domestic cats with blood type A were found to pass compatibility tests. Interestingly, 3/10 of the tigers’ red blood cell samples were fully compatible with all cat plasmas, and 1/10 of the tiger plasma samples were fully compatible with the type A red cells of domestic cats. Although the result of present findings revealed type-A blood group in the surveyed tigers, the reaction of tiger plasma with Type-A red cell from cats suggested a possibility of other blood type in tigers. PMID:28450662
Comparative serological investigation between cat and tiger blood for transfusion.
Thengchaisri, Naris; Sinthusingha, Chayakrit; Arthitwong, Surapong; Sattasathuchana, Panpicha
2017-06-29
Evidence suggests that non-domesticated felids inherited the same AB-erythrocyte antigens as domestic cats. To study the possible compatibility of tiger blood with that of other endangered felidae, blood samples from captive tigers and domestic cats were subjected to an in vitro study. The objectives of this study were to (1) identify whether the captive tigers had blood type AB and (2) determine the compatibility between the blood of captive tigers and that of domestic cats with a similar blood type. The anti-coagulated blood with ethylenediaminetetraacetic acid of 30 tigers was examined to determine blood type, and a crossmatching test was performed between tiger and cat blood. All 30 tigers had blood type A. Tube agglutination tests using tiger plasma with cat erythrocytes resulted in 100% agglutination (n=30) with type B cat erythrocytes and 76.7% agglutination (n=23) with type A cat erythrocytes. The 80% of major and 60% of minor compatibilities between blood from 10 tigers and 10 domestic cats with blood type A were found to pass compatibility tests. Interestingly, 3/10 of the tigers' red blood cell samples were fully compatible with all cat plasmas, and 1/10 of the tiger plasma samples were fully compatible with the type A red cells of domestic cats. Although the result of present findings revealed type-A blood group in the surveyed tigers, the reaction of tiger plasma with Type-A red cell from cats suggested a possibility of other blood type in tigers.
NASA Technical Reports Server (NTRS)
Diwan, Ravinder M.
1989-01-01
The behavior of liquid oxygen (LOX) compatibility of aluminum lithium (Al-Li) alloys is investigated. Alloy systems of Alcoa 2090, vintages 1 to 3, and of Martin Marietta Corporation (MMC) Weldalite 049 were evaluated for their behavior related to the LOX compatibility employing liquid oxygen impact test conditions under ambient pressures and up to 1000 psi. The developments of these aluminum lithium alloys are of critical and significant interest because of their lower densities and higher specific strengths and improved mechanical properties at cryogenic temperatures. Of the different LOX impact tests carried out at the Marshall Space Flight Center (MSFC), it is seen that in certain test conditions at higher pressures, not all Al-Li alloys are LOX compatible. In case of any reactivity, it appears that lithium makes the material more sensitive at grain boundaries due to microstructural inhomogeneities and associated precipitate free zones (PFZ). The objectives were to identify and rationalize the microstructural mechanisms that could be relaxed to LOX compatibility behavior of the alloy system in consideration. The LOX compatibility behavior of Al-Li 2090 and Weldalite 049 is analyzed in detail using microstructural characterization techniques with light optical metallography, scanning electron microscopy (SEM), electron microprobe analysis, and surface studies using secondary ion mass spectrometry (SIMS), electron spectroscopy in chemical analysis (ESCA) and Auger electron spectroscopy (AES). Differences in the behavior of these aluminum lithium alloys are assessed and related to their chemistry, heat treatment conditions, and microstructural effects.
Echocardiography as an indication of continuous-time cardiac quiescence
NASA Astrophysics Data System (ADS)
Wick, C. A.; Auffermann, W. F.; Shah, A. J.; Inan, O. T.; Bhatti, P. T.; Tridandapani, S.
2016-07-01
Cardiac computed tomography (CT) angiography using prospective gating requires that data be acquired during intervals of minimal cardiac motion to obtain diagnostic images of the coronary vessels free of motion artifacts. This work is intended to assess B-mode echocardiography as a continuous-time indication of these quiescent periods to determine if echocardiography can be used as a cost-efficient, non-ionizing modality to develop new prospective gating techniques for cardiac CT. These new prospective gating approaches will not be based on echocardiography itself but on CT-compatible modalities derived from the mechanics of the heart (e.g. seismocardiography and impedance cardiography), unlike the current standard electrocardiogram. To this end, echocardiography and retrospectively-gated CT data were obtained from ten patients with varied cardiac conditions. CT reconstructions were made throughout the cardiac cycle. Motion of the interventricular septum (IVS) was calculated from both echocardiography and CT reconstructions using correlation-based, deviation techniques. The IVS was chosen because it (1) is visible in echocardiography images, whereas the coronary vessels generally are not, and (2) has been shown to be a suitable indicator of cardiac quiescence. Quiescent phases were calculated as the minima of IVS motion and CT volumes were reconstructed for these phases. The diagnostic quality of the CT reconstructions from phases calculated from echocardiography and CT data was graded on a four-point Likert scale by a board-certified radiologist fellowship-trained in cardiothoracic radiology. Using a Wilcoxon signed-rank test, no significant difference in the diagnostic quality of the coronary vessels was found between CT volumes reconstructed from echocardiography- and CT-selected phases. Additionally, there was a correlation of 0.956 between the echocardiography- and CT-selected phases. This initial work suggests that B-mode echocardiography can be used as a tool to develop CT-compatible gating techniques based on modalities derived from cardiac mechanics rather than relying on the ECG alone.
NASA Astrophysics Data System (ADS)
Cao, Yuan; Zhao, Yongli; Yu, Xiaosong; Han, Jiawei; Zhang, Jie
2017-11-01
A PANDA polarization-maintaining few-mode ring-core fiber (PM-FM-RCF) structure with two air holes around the ring core is proposed. The relative mode multiplicity factor (RMMF) is defined to evaluate the spatial efficiency of the designed PM-FM-RCF. The performance analysis and comparison of the proposed PANDA PM-FM-RCFs considering three different types of step-index profiles are detailed. Through modal characteristic analysis and numerical simulation, the PM-FM-RCF with a lower refractive index difference (Δnoi=1.5%) between the ring core and the inner central circle can support up to 16 polarization modes with large RMMF at C-band, which shows the optimum modal properties compared with the PM-FM-RCF with higher Δnoi. All the supported polarization modes are effectively separated from their adjacent polarization modes with effective refractive index differences (Δn) larger than 10-4, which also show relatively small chromatic dispersion (-20 to 25 ps/nm/km), low attenuation (<1.4 dB/km), and small bending radius (˜8 mm) over the C-band. The designed PM-FM-RCF can be compatible with standard single-mode fibers and applied in multiple-input multiple-output-free spatial division multiplexing optical networks for short-reach optical interconnection.
Being While Doing: An Inductive Model of Mindfulness at Work
Lyddy, Christopher J.; Good, Darren J.
2017-01-01
Mindfulness at work has drawn growing interest as empirical evidence increasingly supports its positive workplace impacts. Yet theory also suggests that mindfulness is a cognitive mode of “Being” that may be incompatible with the cognitive mode of “Doing” that undergirds workplace functioning. Therefore, mindfulness at work has been theorized as “being while doing,” but little is known regarding how people experience these two modes in combination, nor the influences or outcomes of this interaction. Drawing on a sample of 39 semi-structured interviews, this study explores how professionals experience being mindful at work. The relationship between Being and Doing modes demonstrated changing compatibility across individuals and experience, with two basic types of experiences and three types of transitions. We labeled experiences when informants were unable to activate Being mode while engaging Doing mode as Entanglement, and those when informants reported simultaneous co-activation of Being and Doing modes as Disentanglement. This combination was a valuable resource for offsetting important limitations of the typical reliance on the Doing cognitive mode. Overall our results have yielded an inductive model of mindfulness at work, with the core experience, outcomes, and antecedent factors unified into one system that may inform future research and practice. PMID:28270775
Ratner, Buddy D.
2007-01-01
The biomaterials community has been unable to accurately assign the term “blood compatible” to a biomaterial in spite of 50 years of intensive research on the subject. There is no clear consensus as to which materials are “blood compatible.” There are no standardized methods to assess blood compatibility. Since we use millions of devices in contact with blood each year, it is imperative we give serious thought to this intellectual catastrophe. In this perspective, I consider five hypotheses as to why progress has been slow in evolving a clear understanding of blood compatibility: Hypothesis 1 -- It is impossible to make a blood compatible material. Hypothesis 2 -- We do not understand the biology behind blood compatibility. Hypothesis 3 -- We do not understand how to test for or evaluate blood compatibility. Hypothesis 4 -- Certain materials of natural origin seem to show better blood compatibility but we do not know how to exploit this concept. Hypothesis 5 -- We now have better blood compatible materials but the regulatory and economic climate prevent adoption in clinical practice. PMID:17689608
NASA Technical Reports Server (NTRS)
1980-01-01
The compatibility of the Multimission Modular Spacecraft (MMS) Ground Support Software System (GSSS), currently operational on a ModComp IV/35, with the VAX 11/780 system is discussed. The compatibility is examined in various key areas of the GSSS through the results of in depth testing performed on the VAX 11/780 and ModComp IV/35 systems. The compatibility of the GSSS with the ModComp CLASSIC is presented based upon projections from ModComp supplied literature.
Electrochemical Genosensing of Circulating Biomarkers
Campuzano, Susana; Yáñez-Sedeño, Paloma; Pingarrón, José Manuel
2017-01-01
Management and prognosis of diseases requires the measurement in non- or minimally invasively collected samples of specific circulating biomarkers, consisting of any measurable or observable factors in patients that indicate normal or disease-related biological processes or responses to therapy. Therefore, on-site, fast and accurate determination of these low abundance circulating biomarkers in scarcely treated body fluids is of great interest for health monitoring and biological applications. In this field, electrochemical DNA sensors (or genosensors) have demonstrated to be interesting alternatives to more complex conventional strategies. Currently, electrochemical genosensors are considered very promising analytical tools for this purpose due to their fast response, low cost, high sensitivity, compatibility with microfabrication technology and simple operation mode which makes them compatible with point-of-care (POC) testing. In this review, the relevance and current challenges of the determination of circulating biomarkers related to relevant diseases (cancer, bacterial and viral infections and neurodegenerative diseases) are briefly discussed. An overview of the electrochemical nucleic acid–based strategies developed in the last five years for this purpose is given to show to both familiar and non-expert readers the great potential of these methodologies for circulating biomarker determination. After highlighting the main features of the reported electrochemical genosensing strategies through the critical discussion of selected examples, a conclusions section points out the still existing challenges and future directions in this field. PMID:28420103
Santos, Cleusa C.; Feitosa, Fabiana G.; Ribeiro, Maria C.; Menge, Paulo; Lira, Izabelle M.
2017-01-01
Objective To report the echocardiographic evaluation of 103 infants with presumed congenital Zika syndrome. Methods An observational retrospective study was performed at Instituto de Medicina Integral Prof. Fernando Figueira (IMIP), Recife, Brazil. 103 infants with presumed congenital Zika syndrome. All infants had microcephaly and head computed tomography findings compatible with congenital Zika syndrome. Zika IgM antibody was detected in cerebrospinal fluid samples of 23 infants. In 80 infants, the test was not performed because it was not available at that time. All infants had negative serology for HIV, syphilis, rubella, cytomegalovirus and toxoplasmosis. A complete transthoracic two-dimensional, M-mode, continuous wave and pulsed wave Doppler and color Doppler echocardiographic (PHILIPS HD11XE or HD15) examination was performed on all infants. Results 14/103 (13.5%) echocardiograms were compatible with congenital heart disease: 5 with an ostium secundum atrial septal defect, 8 had a hemodynamically insignificant small apical muscular ventricular septal defect and one infant with dyspnea had a large membranous ventricular septal defect. The echocardiograms considered normal included 45 infants with a persistent foramen ovale and 16 with a minimum patent ductus arteriosus. Conclusions Preliminarily this study suggests that congenital Zika syndrome may be associated with an increase prevalence of congenital heart disease. However the types of defects noted were septal defects, a proportion of which would not be hemodynamically significant. PMID:28426680
Selection and propagation of highly graft-compatible Douglas-fir rootstocksa case history.
Donald L. Copes
1981-01-01
Two populations of Douglas-fir trees were screened for graft compatibility. Two-stage testing procedures were used with either high- or low-intensity screening in the first step. Of 303 trees, 16 (5 percent) were found to be 90- to 100-percent graft compatible and suitable for seed orchard use as rootstocks. High-intensity screening in the first stage was more...
78 FR 1162 - Cardiovascular Devices; Reclassification of External Cardiac Compressor
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-08
... safety and electromagnetic compatibility; For devices containing software, software verification... electromagnetic compatibility; For devices containing software, software verification, validation, and hazard... electrical components, appropriate analysis and testing must validate electrical safety and electromagnetic...
DOE Office of Scientific and Technical Information (OSTI.GOV)
MM Hall
2006-01-31
A major materials selection and qualification issue identified in the Space Materials Plan is the potential for creating materials compatibility problems by combining dissimilar reactor core, Brayton Unit and other power conversion plant materials in a recirculating, inert He/Xe gas loop containing reactive impurity gases. Reported here are results of equilibrium thermochemical analyses that address the compatibility of space nuclear power plant (SNPP) materials in high temperature impure He gas environments. These studies provide early information regarding the constraints that exist for SNPP materials selection and provide guidance for establishing test objectives and environments for SNPP materials qualification testing.
Steady state scenario development with elevated minimum safety factor on DIII-D
Holcomb, Christopher T.; Ferron, John R.; Luce, Timothy C.; ...
2014-08-15
On DIII-D, a high β scenario with minimum safety factor (q min) near 1.4 has been optimized with new tools and shown to be a favourable candidate for long pulse or steady state operation in future devices. Furthermore, the new capability to redirect up to 5 MW of neutral beam injection (NBI) from on- to off-axis improves the ability to sustain elevated q min with a less peaked pressure profile. The observed changes increase the ideal magnetohydrodynamics (MHD) n = 1 mode β N limit thus providing a path forward for increasing the noninductive current drive fraction by operating atmore » high β N. Quasi-stationary discharges free of tearing modes have been sustained at βN = 3.5 and β T = 3.6% for two current profile diffusion timescales (about 3 s) limited by neutral beam duration. The discharge performance has normalized fusion performance expected to give fusion gain Q ≈ 5 in a device the size of ITER. Analysis of the poloidal flux evolution and current drive balance show that the loop voltage profile is almost relaxed even with 25% of the current driven inductively, and q min remains elevated near 1.4. Our observations increase confidence that the current profile will not evolve to one unstable to a tearing mode. In preliminary tests a divertor heat flux reduction technique based on producing a radiating mantle with neon injection appears compatible with this operating scenario. 0D model extrapolations suggest it may be possible to push this scenario up to 100% noninductive current drive by raising β N. Similar discharges with q min = 1.5–2 were susceptible to tearing modes and off-axis fishbones, and with q min > 2 lower normalized global energy confinement time is observed.« less
Wang, Jing; Qi, Minghao; Xuan, Yi; Huang, Haiyang; Li, You; Li, Ming; Chen, Xin; Jia, Qi; Sheng, Zhen; Wu, Aimin; Li, Wei; Wang, Xi; Zou, Shichang; Gan, Fuwan
2014-01-01
A novel silicon-on-insulator (SOI) polarization splitter-rotator (PSR) with a large fabrication tolerance is proposed based on cascaded multimode interference (MMI) couplers and an assisted mode-evolution taper. The tapers are designed to adiabatically convert the input TM0 mode into the TE1 mode, which will output as the TE0 mode after processed by the subsequent MMI mode converter, 90-degree phase shifter (PS) and MMI 3 dB coupler. The numerical simulation results show that the proposed device has a < 0.5 dB insertion loss with < −17 dB crosstalk in C optical communication band. Fabrication tolerance analysis is also performed with respect to the deviations of MMI coupler width, PS width, slab height and upper-cladding refractive index, showing that this device could work well even when affected by considerable fabrication errors. With such a robust performance with a large bandwidth, this device offers potential applications for CMOS-compatible polarization diversity, especially in the booming 100 Gb/s coherent optical communications based on silicon photonics technology. PMID:25402029
Wang, Jing; Qi, Minghao; Xuan, Yi; Huang, Haiyang; Li, You; Li, Ming; Chen, Xin; Jia, Qi; Sheng, Zhen; Wu, Aimin; Li, Wei; Wang, Xi; Zou, Shichang; Gan, Fuwan
2014-11-17
A novel silicon-on-insulator (SOI) polarization splitter-rotator (PSR) with a large fabrication tolerance is proposed based on cascaded multimode interference (MMI) couplers and an assisted mode-evolution taper. The tapers are designed to adiabatically convert the input TM(0) mode into the TE(1) mode, which will output as the TE(0) mode after processed by the subsequent MMI mode converter, 90-degree phase shifter (PS) and MMI 3 dB coupler. The numerical simulation results show that the proposed device has a < 0.5 dB insertion loss with < -17 dB crosstalk in C optical communication band. Fabrication tolerance analysis is also performed with respect to the deviations of MMI coupler width, PS width, slab height and upper-cladding refractive index, showing that this device could work well even when affected by considerable fabrication errors. With such a robust performance with a large bandwidth, this device offers potential applications for CMOS-compatible polarization diversity, especially in the booming 100 Gb/s coherent optical communications based on silicon photonics technology.
Microcalorimeters with Germanium Thermistors for High Resolution Soft and Hard X-ray Astronomy
NASA Technical Reports Server (NTRS)
Silver, E.
2003-01-01
This is a progress report for the first year of a three year Space Research and Technology (SR&T) grant to continue the advancement of neutron transmutation doped (NTD-based) microcalorimeters. We have re-prioritized certain aspects of the statement of work and chose to emphasize issues of array development in the first year rather than wait until year two. Consequently, some of the projects scheduled for the first year were delayed to the second year. Here we report on our progress to: a) Build and test a 1 x 4 element array and to investigate electrical and thermal cross-talk; b) Build a multiplexed 4 channel analog pulse processor; c) Build a digital pulse processor that can accommodate 4 channels with independent triggers; d) Develop a proportional thermal baseline restoration system compatible with the constant voltage mode of microcalorimeter operation.
A graphical language for reliability model generation
NASA Technical Reports Server (NTRS)
Howell, Sandra V.; Bavuso, Salvatore J.; Haley, Pamela J.
1990-01-01
A graphical interface capability of the hybrid automated reliability predictor (HARP) is described. The graphics-oriented (GO) module provides the user with a graphical language for modeling system failure modes through the selection of various fault tree gates, including sequence dependency gates, or by a Markov chain. With this graphical input language, a fault tree becomes a convenient notation for describing a system. In accounting for any sequence dependencies, HARP converts the fault-tree notation to a complex stochastic process that is reduced to a Markov chain which it can then solve for system reliability. The graphics capability is available for use on an IBM-compatible PC, a Sun, and a VAX workstation. The GO module is written in the C programming language and uses the Graphical Kernel System (GKS) standard for graphics implementation. The PC, VAX, and Sun versions of the HARP GO module are currently in beta-testing.
Studies on Stress-Strain Relationships of Polymeric Materials Used in Space Applications
NASA Technical Reports Server (NTRS)
Jana, Sadhan C.; Freed, Alan
2002-01-01
A two-year research plan was undertaken in association with Polymers Branch, NASA Glenn Research Center, to carry out experimental and modeling work relating stress and strain behavior of polymeric materials, especially elastomers and vulcanized rubber. An experimental system based on MTS (Mechanical Testing and Simulation) A/T-4 test facility environment has been developed for a broader range of polymeric materials in addition to a design of laser compatible temperature control chamber for online measurements of various strains. Necessary material processing has been accomplished including rubber compounding and thermoplastic elastomer processing via injection molding. A broad suite of testing methodologies has been identified to reveal the complex non-linear mechanical behaviors of rubbery materials when subjected to complex modes of deformation. This suite of tests required the conceptualization, design and development of new specimen geometries, test fixtures, and test systems including development of a new laser based technique to measure large multi-axial deformations. Test data has been generated for some of these new fixtures and has revealed some complex coupling effects generated during multi-axial deformations. In addition, fundamental research has been conducted concerning the foundation principles of rubber thermodynamics and resulting theories of rubber elasticity. Studies have been completed on morphological properties of several thermoplastic elastomers. Finally, a series of steps have been identified to further advance the goals of NASA's ongoing effort.
Environmentally Friendly Corrosion Preventative Compounds
NASA Technical Reports Server (NTRS)
Calle, Luz Marina; Montgomery, Eliza; Kolody, Mark; Curran, Jerry; Back, Teddy; Balles, Angela
2012-01-01
The objective of the Ground Systems Development and Operations Program Environmentally Friendly Corrosion Protective Coatings and Corrosion Preventive Compounds (CPCs) project is to identify, test, and develop qualification criteria for the use of environmentally friendly corrosion protective coatings and CPCs for flight hardware and ground support equipment. This document is the Final Report for Phase I evaluations, which included physical property, corrosion resistance, and NASA spaceport environment compatibility testing and analysis of fifteen CPC types. The CPCs consisted of ten different oily film CPCs and five different wax or grease CPC types. Physical property testing encompassed measuring various properties of the bulk CPCs, while corrosion resistance testing directly measured the ability of each CPC material to protect various metals against corrosion. The NASA spaceport environment compatibility testing included common tests required by NASA-STD-6001, "Flammability, Odor, Offgassing, and Compatibility Requirements and Test Procedures for Materials in Environments that Support Combustion". At the end of Phase I, CPC materials were down-selected for inclusion in the next test phases. This final report includes all data and analysis of results obtained by following the experimental test plan that was developed as part of the project. Highlights of the results are summarized by test criteria type.
Three conceptual units for behavior
Moxley, Roy
1987-01-01
Three generic units for behavior are examined in terms of their background: an if-then unit for stimulus and response (S-R), a holistic unit for Kantor's behavior segment, and an AB-because-of-C unit for Skinner's three-term contingency. The units are distinguished in terms of their respective historical backgrounds, causal modes, advantages, and disadvantages. The ways in which these units may be compatible are discussed. PMID:22477957
Ayal, Shahar; Rusou, Zohar; Zakay, Dan; Hochman, Guy
2015-01-01
A framework is presented to better characterize the role of individual differences in information processing style and their interplay with contextual factors in determining decision making quality. In Experiment 1, we show that individual differences in information processing style are flexible and can be modified by situational factors. Specifically, a situational manipulation that induced an analytical mode of thought improved decision quality. In Experiment 2, we show that this improvement in decision quality is highly contingent on the compatibility between the dominant thinking mode and the nature of the task. That is, encouraging an intuitive mode of thought led to better performance on an intuitive task but hampered performance on an analytical task. The reverse pattern was obtained when an analytical mode of thought was encouraged. We discuss the implications of these results for the assessment of decision making competence, and suggest practical directions to help individuals better adjust their information processing style to the situation at hand and make optimal decisions. PMID:26284011
Ayal, Shahar; Rusou, Zohar; Zakay, Dan; Hochman, Guy
2015-01-01
A framework is presented to better characterize the role of individual differences in information processing style and their interplay with contextual factors in determining decision making quality. In Experiment 1, we show that individual differences in information processing style are flexible and can be modified by situational factors. Specifically, a situational manipulation that induced an analytical mode of thought improved decision quality. In Experiment 2, we show that this improvement in decision quality is highly contingent on the compatibility between the dominant thinking mode and the nature of the task. That is, encouraging an intuitive mode of thought led to better performance on an intuitive task but hampered performance on an analytical task. The reverse pattern was obtained when an analytical mode of thought was encouraged. We discuss the implications of these results for the assessment of decision making competence, and suggest practical directions to help individuals better adjust their information processing style to the situation at hand and make optimal decisions.
Coupling effects in the modal emission of colloidal quantum dot microdisk lasers.
NASA Astrophysics Data System (ADS)
Lafalce, Evan; Zheng, Qingji; Lin, Chunhao; Smith, Marcus; Malak, Sidney; Jung, Jaehan; Yoon, Young; Lin, Zhiqun; Tsukruk, Vladimir; Vardeny, Z. Valy
Solution-processed semiconductors such as colloidal quantum dots (CQD) are particularly suited materials for monolithic fabrication of laser microstructures because of their ease of fabrication and compatibility with conventional lithographic techniques. We use the functionality of core/alloyed-shell CQDs to fabricate microdisk lasers of variable size and study the resulting whispering-gallery mode laser emission. In particular we study the effects of near-field coupling on resonant modes of pairs of these lasers with sub-micrometer spacing. We demonstrate the occurrence of lasing modes that originate from the interaction between two such microdisks by means of varying the spatial distribution and magnitude of the gain and loss in the coupled-pair. The transition from emission of modes localized on a single disk to those of the interacting pair is accompanied by coalescence of eigen-frequencies and pump-induced turn-off of lasing, highlighting the role of parity-time symmetry and exceptional point physics. This work was funded by AFOSR through MURI Grant RA 9550-14-1-0037.
Effect of the eruption of El Chichon stratospheric aerosol size and composition
NASA Technical Reports Server (NTRS)
Oberbeck, V. R.; Danielsen, E. F.; Snetsinger, K. G.; Ferry, G. V.; Fong, W.; Hayes, D. M.
1983-01-01
Dominant effects of the El Chichon eruption on stratospheric aerosols at 19.8 to 20.7 km are: (1) vapor depositional growth of the small-aerosol (background) mode; (2) development of a large-particle mode by sedimentation from the highest altitudes in the cloud; (3) a change in the large-particle mode from sulfate-coated silicates to sulfate aerosols, some with silicate cores; (4) a 100-fold increase in sulfate mass in the large particle mode. Terminal velocities of large silicate particles, maximum r = 2.3 micron, sampled 1 month after eruption, and calibrated with the aid of lidar data, indicate initial injection to 26 to 27 km. Smaller velocities of sulfate aerosols, median r = 0.5 micron, are compatible with major growth in 2 to 3 months at 27 to 28 km. Aerosol settling accounts for the descent of the main lidar return to 26.5 km in August and to 20 to 21 km in December.
Application of Solar-Electric Propulsion to Robotic Missions in Near-Earth Space
NASA Technical Reports Server (NTRS)
Woodcock, Gordon R.; Dankanich, John
2007-01-01
Interest in applications of solar electric propulsion (SEP) is increasing. Application of SEP technology is favored when: (1) the mission is compatible with low-thrust propulsion, (2) the mission needs high total delta V such that chemical propulsion is disadvantaged; and (3) performance enhancement is needed. If all such opportunities for future missions are considered, many uses of SEP are likely. Representative missions are surveyed and several SEP applications selected for analysis, including orbit raising, lunar science and robotic exploration, and planetary science. These missions span SEP power range from 10 kWe to about 100 kWe. A SEP design compatible with small inexpensive launch vehicles, and capable of lunar science missions, is presented. Modes of use and benefits are described, and potential SEP evolution is discussed.
Ultralow-Loss CMOS Copper Plasmonic Waveguides.
Fedyanin, Dmitry Yu; Yakubovsky, Dmitry I; Kirtaev, Roman V; Volkov, Valentyn S
2016-01-13
Surface plasmon polaritons can give a unique opportunity to manipulate light at a scale well below the diffraction limit reducing the size of optical components down to that of nanoelectronic circuits. At the same time, plasmonics is mostly based on noble metals, which are not compatible with microelectronics manufacturing technologies. This prevents plasmonic components from integration with both silicon photonics and silicon microelectronics. Here, we demonstrate ultralow-loss copper plasmonic waveguides fabricated in a simple complementary metal-oxide semiconductor (CMOS) compatible process, which can outperform gold plasmonic waveguides simultaneously providing long (>40 μm) propagation length and deep subwavelength (∼λ(2)/50, where λ is the free-space wavelength) mode confinement in the telecommunication spectral range. These results create the backbone for the development of a CMOS plasmonic platform and its integration in future electronic chips.
TM digital image products for applications. [computer compatible tapes
NASA Technical Reports Server (NTRS)
Barker, J. L.; Gunther, F. J.; Abrams, R. B.; Ball, D.
1984-01-01
The image characteristics of digital data generated by LANDSAT 4 thematic mapper (TM) are discussed. Digital data from the TM resides in tape files at various stages of image processing. Within each image data file, the image lines are blocked by a factor of either 5 for a computer compatible tape CCT-BT, or 4 for a CCT-AT and CCT-PT; in each format, the image file has a different format. Nominal geometric corrections which provide proper geodetic relationships between different parts of the image are available only for the CCT-PT. It is concluded that detector 3 of band 5 on the TM does not respond; this channel of data needs replacement. The empty bin phenomenon in CCT-AT images results from integer truncations of mixed-mode arithmetric operations.
Mode Conversion of a Solar Extreme-ultraviolet Wave over a Coronal Cavity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zong, Weiguo; Dai, Yu, E-mail: ydai@nju.edu.cn
2017-01-10
We report on observations of an extreme-ultraviolet (EUV) wave event in the Sun on 2011 January 13 by Solar Terrestrial Relations Observatory and Solar Dynamics Observatory in quadrature. Both the trailing edge and the leading edge of the EUV wave front in the north direction are reliably traced, revealing generally compatible propagation velocities in both perspectives and a velocity ratio of about 1/3. When the wave front encounters a coronal cavity near the northern polar coronal hole, the trailing edge of the front stops while its leading edge just shows a small gap and extends over the cavity, meanwhile gettingmore » significantly decelerated but intensified. We propose that the trailing edge and the leading edge of the northward propagating wave front correspond to a non-wave coronal mass ejection component and a fast-mode magnetohydrodynamic wave component, respectively. The interaction of the fast-mode wave and the coronal cavity may involve a mode conversion process, through which part of the fast-mode wave is converted to a slow-mode wave that is trapped along the magnetic field lines. This scenario can reasonably account for the unusual behavior of the wave front over the coronal cavity.« less
NASA Astrophysics Data System (ADS)
Glazkov, Yury; Artjuchin, Yury; Astakhov, Alexander; Vas'kov, Alexander; Malyshev, Veniamin; Mitroshin, Edward; Glinsky, Valery; Moiseenko, Vasily; Makovlev, Vyacheslav
The development of aircraft-type reusable space vehicles (RSV) involves the problem of complete compatibility of automatic, director and manual control. Task decision is complicated, in particular, due to considerable quantitative and qualitative changes of vehicle dynamic characteristics, little stability margins (and even of unstability) of the RSV, and stringent requirements to control accuracy at some flight phases. Besides, during control a pilot is affected by g-loads which hamper motor activity and deteriorate its accuracy, alter the functional status of the visual analyser, and influence higher nervous activity. A study of g-load effects on the control efficiency, especially in manual and director modes, is of primary importance. The main tools for study of a rational selection of manual and director vehicle control systems and as an aid in formulating recommendations for optimum crew-automatic control system interactions are special complex and functional flight simulator test stands. The proposed simulator stand includes a powerful digital computer complex combined with the control system of the centrifuge. The interior of a pilot's vehicle cabin is imitated. A situation image system, pyscho-physical monitoring system, physician, centrifuge operator, and instructor stations are linked with the test stand.
Potential Damage to Flight Hardware from MIL-STD-462 CS02 Setup
NASA Technical Reports Server (NTRS)
Harris, Patrick K.; Block, Nathan F.
2002-01-01
The MIL-STD-462 CS02 conducted susceptibility test setup, performed during electromagnetic compatibility (EMC) testing, consists of an audio transformer with the secondary used as an inductor and a large capacitor. Together, these two components form an L-type low-pass filter to minimize the injected test signal input into the power source. Some flight hardware power input configurations are not compatible with this setup and break into oscillation when powered up. This can damage flight hardware and caused a catastrophic failure to an item tested in the Goddard Space Flight Center (GSFC) Large EMC Test Facility.
Hydrazine-Compatible Elastomer
NASA Technical Reports Server (NTRS)
Markles, O., F.; Dye, T. G.
1982-01-01
Hydrazine hardly reacts with ethylene propylene diene monomer, even at high temperatures. According to report to tests, EPDM is most hydrazine-compatible material among elastomers. Has strong potential as valve-seat and O-ring seal with hydrazine, especially at high temperatures.
NASA Technical Reports Server (NTRS)
Denson, J. R.; Toy, A.
1974-01-01
Compatibility data for aluminum alloy 2219-T87 and titanium alloy Ti-6Al-4V were obtained while these alloys were exposed to both liquid and vapor fluorine and FLOX at -320 F + or -10 F. These data were obtained using a new low cost compatibility method which incorporates totally sealed containers and double dogbone test specimens and propellants in the simultaneous exposure to vapor and liquid phases. The compatibility investigation covered a storage period in excess of one year. Pitting was more severe in the 2219-T87 aluminum alloy than in the Ti-6Al-4V titanium alloy for both fluorine and FLOX exposure. The degree of chemical attack is more severe in the presence of FLOX than in fluorine and phase. The mechanical properties of the two alloys were not affected by storage in either of the two propellants.
Environmentally compatible hand wipe cleaning solvents
NASA Technical Reports Server (NTRS)
Clayton, Catherine P.; Kovach, Michael P.
1995-01-01
Several solvents of environmental concern have previously been used for hand wipe cleaning of SRB surfaces, including 1,1,1-trichloroethane, perchloroethylene, toluene, xylene, and MEK. USBI determined the major types of surfaces involved, and qualification requirements of replacement cleaning agents. Nineteen environmentally compatible candidates were tested on 33 material substrates with 26 types of potential surface contaminants, involving over 7,000 individual evaluations. In addition to the cleaning performance evaluation, bonding, compatibility, and corrosion tests were conducted. Results showed that one cleaner was not optimum for all surfaces. In most instances, some of the candidates cleaned better than the 1,1,1-trichloroethane baseline control. Aqueous cleaners generally cleaned better, and were more compatible with nonmetallic materials, such as paints, plastics, and elastomers. Organic base cleaners were better on metal surfaces. Five cleaners have been qualified and are now being implemented in SRB hand wipe cleaning operations.
Hyperbaric Oxygen Therapy and Oxygen Compatibility of Skin and Wound Care Products
Bernatchez, Stéphanie F.; Tucker, Joseph; Chiffoleau, Gwenael
2017-01-01
Objective: Use test methods to assess the oxygen compatibility of various wound care products. Approach: There are currently no standard test methods specifically for evaluating the oxygen compatibility and safety of materials under hyperbaric oxygen (HBO) conditions. However, tests such as the oxygen index (OI), oxygen exposure (OE), and autogenous ignition temperature (AIT) can provide useful information. Results: The OI test measures the minimum oxygen concentration that will support candle-like burning, and it was used to test 44 materials. All but two exhibited an OI equal to or greater (safer) than a control material commonly used in HBO. The OE test exposes each material to an oxygen-enriched atmosphere (>99.5% oxygen) to monitor temperature and pressure for an extended duration. The results of the OE testing indicated that none of the 44 articles tested with this method self-ignited within the 60°C, 3 atm pressurized oxygen atmosphere. The AIT test exposes materials to a rapid ramp up in temperature in HBO conditions at 3 atm until ignition occurs. Ten wound care materials and seven materials usually avoided in HBO chambers were tested. The AIT ranged from 138°C to 384°C for wound care products and from 146°C to 420°C for the other materials. Innovation: This work provides useful data and recommendations to help develop a new standard approach for evaluating the HBO compatibility of wound care products to ensure safety for patients and clinicians. Conclusion: The development of an additional test to measure the risk of electrostatic discharge of materials in HBO conditions is needed. PMID:29098113
2012-02-21
Testing and Materials °C Celsius DiEGME Diethylene Glycol Monomethyl Ether EPDM Ethylene Propylene Diene Monomer FARE Forward Area Refueling...urethane class AU, polyether urethane class EU, EPDM , Viton®, fluorosilicone class FQ, polytetrafluoroethylene (PTFE), polyolefin and polyester...sleeve Material not provided AAFARS 4720-00-540-1368 Hose, nonmetallic Material not provided AAFARS 4720-01-218-6958 Hose, preformed Rubber
Assessing a Couple's Relationship and Compatibility Using the MARI[R] Card Test and Mandala Drawings
ERIC Educational Resources Information Center
Frame, Phyllis G.
2006-01-01
This paper illustrates the use of the MARI[R] Card Test, a transpersonal assessment tool which includes archetypal designs and color choices, as well as the drawing of a white and black mandala, or circle picture, for assessing the compatibility of two people in a committed relationship. In an informal pilot research study, 22 couples were given…
EMC (Electromagnetic Compatibility) System Test and Analysis Interface.
1983-05-01
D- R136 64 EMC (ELECTROARGNETIC COMPATIBILITY) SYSTEM TEST AND V ANALYSIS INTE FACE(J) BOEING CO SEATTLE WA E F BALL ET AL MAY 93 RRDC-TR-83-121...RADC-TR-83- 121 Final Tedical Report May 1963 EMC SYSTEM TEST AND ANAL YSIS INTERFACE_ The Boeing Company E. F. Ball, L. Knutson and B. L...Carlson *. . APPROVE FOR PUBLIC REESEk DIS TRIBUTION ULMTED D IS -ELECTE ,... DEC 20 1983 >- D" c: ROME AIR DEVELOPMENT CENTER * Air Force Systems Command
NASA Technical Reports Server (NTRS)
Schwarz, Mark A.; Kent, Craig J.; Bousquet, Robert; Brown, Steven W.
2015-01-01
This work describes the development of an improved vacuum compatible flat plate radiometric source used for characterizing and calibrating remote optical sensors, in situ, throughout their testing period. The original flat plate radiometric source was developed for use by the VIIRS instrument during the NPOESS Preparatory Project (NPP). Following this effort, the FPI has had significant upgrades in order to improve both the radiometric throughput and uniformity. Results of the VIIRS testing with the reconfigured FPI are reported and discussed.
User document for computer programs for ring-stiffened shells of revolution
NASA Technical Reports Server (NTRS)
Cohen, G. A.
1973-01-01
A user manual and related program documentation is presented for six compatible computer programs for structural analysis of axisymmetric shell structures. The programs apply to a common structural model but analyze different modes of structural response. In particular, they are: (1) Linear static response under asymmetric loads; (2) Buckling of linear states under asymmetric loads; (3) Nonlinear static response under axisymmetric loads; (4) Buckling nonlinear states under axisymmetric (5) Imperfection sensitivity of buckling modes under axisymmetric loads; and (6) Vibrations about nonlinear states under axisymmetric loads. These programs treat branched shells of revolution with an arbitrary arrangement of a large number of open branches but with at most one closed branch.
Widened photonic functionality of asymmetric high-index contrast/photonic crystal gratings
NASA Astrophysics Data System (ADS)
Nguyen, Hai Son; Dubois, Florian; Letartre, Xavier; Leclercq, Jean-Louis; Seassal, Christian; Viktorovitch, Pierre
2016-03-01
In this presentation we emphasize that, within the variety of parameters usable for the design of HCGs, the transverse (vertical) symmetry properties of HCGs provide a power-full joystick for the dispersion engineering of guided mode resonances. We concentrate on asymmetric HCGs designed to accommodate guided mode resonances with ultra-flat zero-curvature dispersion characteristics (or photons with ultra-heavy effective mass), as well as with Dirac cone shaped linear dispersion characteristics. Examples of the great potential of this family of asymmetric HCGs will include the development of a platform for polaritonic devices and the production of micro-lasers particularly suited for hybrid III-V / silicon heterogeneous photonic integration, along CMOS compatible technological schemes.
NASA Technical Reports Server (NTRS)
Kot, R. A.; Oliver, J. D.; Wilson, S. G.
1984-01-01
A monolithic, GaAs, dual mode, quadrature amplitude shift keying and quadrature phase shift keying transceiver with one and two billion bits per second data rate is being considered to achieve a low power, small and ultra high speed communication system for satellite as well as terrestrial purposes. Recent GaAs integrated circuit achievements are surveyed and their constituent device types are evaluated. Design considerations, on an elemental level, of the entire modem are further included for monolithic realization with practical fabrication techniques. Numerous device types, with practical monolithic compatability, are used in the design of functional blocks with sufficient performances for realization of the transceiver.
Dark matter candidates: a ten-point test
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taoso, Marco; Masiero, Antonio; Bertone, Gianfranco, E-mail: taoso@pd.infn.it, E-mail: bertone@iap.fr, E-mail: antonio.masiero@pd.infn.it
An extraordinarily rich zoo of non-baryonic dark matter candidates has been proposed over the last three decades. Here we present a ten-point test that a new particle has to pass in order to be considered a viable DM candidate. (I) Does it match the appropriate relic density? (II) Is it cold? (III) Is it neutral? (IV) Is it consistent with BBN? (V) Does it leave stellar evolution unchanged? (VI) Is it compatible with constraints on self-interactions? (VII) Is it consistent with direct DM searches? (VIII) Is it compatible with gamma-ray constraints? (IX) Is it compatible with other astrophysical bounds? (X)more » Can it be probed experimentally?.« less
Reliability and Characteristics of Wafer-Level Chip-Scale Packages under Current Stress
NASA Astrophysics Data System (ADS)
Chen, Po-Ying; Kung, Heng-Yu; Lai, Yi-Shao; Hsiung Tsai, Ming; Yeh, Wen-Kuan
2008-02-01
In this work, we present a novel approach and method for elucidating the characteristics of wafer-level chip-scale packages (WLCSPs) for electromigration (EM) tests. The die in WLCSP was directly attached to the substrate via a soldered interconnect. The shrinking of the area of the die that is available for power, and the solder bump also shrinks the volume and increases the density of electrons for interconnect efficiency. The bump current density now approaches to 106 A/cm2, at which point the EM becomes a significant reliability issue. As known, the EM failure depends on numerous factors, including the working temperature and the under bump metallization (UBM) thickness. A new interconnection geometry is adopted extensively with moderate success in overcoming larger mismatches between the displacements of components during current and temperature changes. Both environments and testing parameters for WLCSP are increasingly demanded. Although failure mechanisms are considered to have been eliminated or at least made manageable, new package technologies are again challenging its process, integrity and reliability. WLCSP technology was developed to eliminate the need for encapsulation to ensure compatibility with smart-mount technology (SMT). The package has good handing properties but is now facing serious reliability problems. In this work, we investigated the reliability of a WLCSP subjected to different accelerated current stressing conditions at a fixed ambient temperature of 125 °C. A very strong correlation exists between the mean time to failure (MTTF) of the WLCSP test vehicle and the mean current density that is carried by a solder joint. A series of current densities were applied to the WLCSP architecture; Black's power law was employed in a failure mode simulation. Additionally, scanning electron microscopy (SEM) was adopted to determine the differences existing between high- and low-current-density failure modes.
Evaluating the compatibility of multi-functional and intensive urban land uses
NASA Astrophysics Data System (ADS)
Taleai, M.; Sharifi, A.; Sliuzas, R.; Mesgari, M.
2007-12-01
This research is aimed at developing a model for assessing land use compatibility in densely built-up urban areas. In this process, a new model was developed through the combination of a suite of existing methods and tools: geographical information system, Delphi methods and spatial decision support tools: namely multi-criteria evaluation analysis, analytical hierarchy process and ordered weighted average method. The developed model has the potential to calculate land use compatibility in both horizontal and vertical directions. Furthermore, the compatibility between the use of each floor in a building and its neighboring land uses can be evaluated. The method was tested in a built-up urban area located in Tehran, the capital city of Iran. The results show that the model is robust in clarifying different levels of physical compatibility between neighboring land uses. This paper describes the various steps and processes of developing the proposed land use compatibility evaluation model (CEM).
Low-Loss Photonic Reservoir Computing with Multimode Photonic Integrated Circuits.
Katumba, Andrew; Heyvaert, Jelle; Schneider, Bendix; Uvin, Sarah; Dambre, Joni; Bienstman, Peter
2018-02-08
We present a numerical study of a passive integrated photonics reservoir computing platform based on multimodal Y-junctions. We propose a novel design of this junction where the level of adiabaticity is carefully tailored to capture the radiation loss in higher-order modes, while at the same time providing additional mode mixing that increases the richness of the reservoir dynamics. With this design, we report an overall average combination efficiency of 61% compared to the standard 50% for the single-mode case. We demonstrate that with this design, much more power is able to reach the distant nodes of the reservoir, leading to increased scaling prospects. We use the example of a header recognition task to confirm that such a reservoir can be used for bit-level processing tasks. The design itself is CMOS-compatible and can be fabricated through the known standard fabrication procedures.
Potential Damage to Flight Hardware from MIL-STD-462 CS02 Setup
NASA Technical Reports Server (NTRS)
Harris, Patrick K.; Block, Nathan F.
2003-01-01
The MIL-STD-462 CS02 conducted susceptibility test setup includes an audio transformer, with the secondary used as an inductor, and a large capacitor. Together, these two components form an L-type low-pass filter to minimize the injected test signal input into the power source. Some flight hardware power input configurations are not compatible with this setup and break into oscillation when powered up. This, in turn, can damage flight hardware. Such an oscillation resulted in the catastrophic failure of an item tested in the Goddard Space Flight Center (GSFC) Large electromagnetic compatibility (EMC) Test Facility.
Compatibility testing of vacuum seal materials
NASA Astrophysics Data System (ADS)
Foster, P. A.; Rodin, W. A.
1993-05-01
Small scale materials compatibility testing was conducted for three elastomers considered for use as vacuum seal materials: Adiprene MOCA-cured; Adiprene Cyanacured; and Sylgard silastic rubber. The tests were conducted using orthogonal array designed experiments for each of the elastomers placed in contact with three materials commonly used during weapon disassembly operations: Duxseal, Sylgard 186 grease, and 2-propyl alcohol. The test results indicated that only the 2-propyl alcohol had a significant effect on the elastomer hardness and physical properties. The alcohol had the largest effect on the two Adiprene materials, and the silastic rubber was the least affected.
DOT National Transportation Integrated Search
2000-04-01
The Coast Guard funded the National Telecommunications and Information Administration : (NTIA) to perform electromagnetic compatibility (EMC) tests between an ITU-R M. 825-3 : (Characteristics Of a Transponder System Using Digital Selective Calling T...
Effect of Time on Gypsum-Impression Material Compatibility
NASA Astrophysics Data System (ADS)
Won, John Boram
The purpose of this study was to evaluate the compatibility of dental gypsum with three recently introduced irreversible hydrocolloid (alginate) alternatives. The test materials were Alginot® (Kerr™), Position Penta Quick® (3M ESPE™) and Silgimix ® (Sultan Dental™). The irreversible hydrocolloid impression material, Jeltrate Plus antimicrobial® (Dentsply Caulk™) served as the control.
NASA Technical Reports Server (NTRS)
Campbell, Colin; Cox, Marlon; Meginnis, Carly; Falconi, Eric
2017-01-01
The Variable Oxygen Regulator (VOR), a stepper actuated two-stage mechanical regulator, is being developed for the purpose of serving as the Primary Oxygen Regulator (POR) and Secondary Oxygen Regulator (SOR) within the Advanced EMU PLSS, now referred to as the xEMU and xPLSS. Three prototype designs have been fabricated and tested as part of this development. Building upon the lessons learned from the 35 years of Shuttle/ISS EMU Program operation including the fleet-wide EMU Secondary Oxygen Pack (SOP) contamination failure that occurred in 2000, the VOR is being analyzed, designed, and tested for oxygen compatibility with controlled Non-Volatile Residue (NVR) and a representative worst-case hydro-carbon system contamination event (>100mg/sq ft dodecane). This paper discusses the steps taken in testing of VOR 2.0 with for oxygen compatibility and then discusses follow-on design changes implemented in the VOR 3.0 (3rd prototype) as a result.
Electrochemical detection for microscale analytical systems: a review.
Wang, Joseph
2002-02-11
As the field of chip-based microscale systems continues its rapid growth, there are urgent needs for developing compatible detection modes. Electrochemistry detection offers considerable promise for such microfluidic systems, with features that include remarkable sensitivity, inherent miniaturization and portability, independence of optical path length or sample turbidity, low cost, low-power requirements and high compatibility with advanced micromachining and microfabrication technologies. This paper highlights recent advances, directions and key strategies in controlled-potential electrochemical detectors for miniaturized analytical systems. Subjects covered include the design and integration of the electrochemical detection system, its requirements and operational principles, common electrode materials, derivatization reactions, electrical-field decouplers, typical applications and future prospects. It is expected that electrochemical detection will become a powerful tool for microscale analytical systems and will facilitate the creation of truly portable (and possibly disposable) devices.
NASA Astrophysics Data System (ADS)
Ishizawa, Y.; Abe, K.; Shirako, G.; Takai, T.; Kato, H.
The electromagnetic compatibility (EMC) control method, system EMC analysis method, and system test method which have been applied to test the components of the MOS-1 satellite are described. The merits and demerits of the problem solving, specification, and system approaches to EMC control are summarized, and the data requirements of the SEMCAP (specification and electromagnetic compatibility analysis program) computer program for verifying the EMI safety margin of the components are sumamrized. Examples of EMC design are mentioned, and the EMC design process and selection method for EMC critical points are shown along with sample EMC test results.
Mixed-mode chromatography/isotope ratio mass spectrometry.
McCullagh, James S O
2010-03-15
Liquid chromatography coupled to molecular mass spectrometry (LC/MS) has been a standard technique since the early 1970s but liquid chromatography coupled to high-precision isotope ratio mass spectrometry (LC/IRMS) has only been available commercially since 2004. This development has, for the first time, enabled natural abundance and low enrichment delta(13)C measurements to be applied to individual analytes in aqueous mixtures creating new opportunities for IRMS applications, particularly for the isotopic study of biological molecules. A growing number of applications have been published in a range of areas including amino acid metabolism, carbohydrates studies, quantification of cellular and plasma metabolites, dietary tracer and nucleic acid studies. There is strong potential to extend these to new compounds and complex matrices but several challenges face the development of LC/IRMS methods. To achieve accurate isotopic measurements, HPLC separations must provide baseline-resolution between analyte peaks; however, the design of current liquid interfaces places severe restrictions on compatible flow rates and in particular mobile phase compositions. These create a significant challenge on which reports associated with LC/IRMS have not previously focused. Accordingly, this paper will address aspects of chromatography in the context of LC/IRMS, in particular focusing on mixed-mode separations and their benefits in light of these restrictions. It aims to provide an overview of mixed-mode stationary phases and of ways to improve high aqueous separations through manipulation of parameters such as column length, temperature and mobile phase pH. The results of several practical experiments are given using proteogenic amino acids and nucleosides both of which are of noted importance in the LC/IRMS literature. This communication aims to demonstrate that mixed-mode stationary phases provide a flexible approach given the constraints of LC/IRMS interface design and acts as a practical guide for the development of new chromatographic methods compatible with LC/IRMS applications. Copyright 2010 John Wiley & Sons, Ltd.
Double Retort System for Materials Compatibility Testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
V. Munne; EV Carelli
2006-02-23
With Naval Reactors (NR) approval of the Naval Reactors Prime Contractor Team (NRPCT) recommendation to develop a gas cooled reactor directly coupled to a Brayton power conversion system as the Space Nuclear Power Plant (SNPP) for Project Prometheus (References a and b) there was a need to investigate compatibility between the various materials to be used throughout the SNPP. Of particular interest was the transport of interstitial impurities from the nickel-base superalloys, which were leading candidates for most of the piping and turbine components to the refractory metal alloys planned for use in the reactor core. This kind of contaminationmore » has the potential to affect the lifetime of the core materials. This letter provides technical information regarding the assembly and operation of a double retort materials compatibility testing system and initial experimental results. The use of a double retort system to test materials compatibility through the transfer of impurities from a source to a sink material is described here. The system has independent temperature control for both materials and is far less complex than closed loops. The system is described in detail and the results of three experiments are presented.« less
Kelly-Cirino, Cassandra D; Curry, Patricia S; Marola, Jamie L; Helstrom, Niels K; Salfinger, Max
2016-11-01
OMNIgene®•SPUTUM (OM-S) is a sputum transport reagent designed to work with all tuberculosis diagnostics and eliminate the need for cold chain. The aim of this preliminary study was to assess the compatibility of OM-S-treated sputum with the Xpert® MTB/RIF assay. Fifty-five characterized sputa from the FIND TB Specimen Bank were used. Compatibility of OM-S was assessed for both Xpert sample preparation methods: H.1 protocol (sediment, n=25) and H.2 protocol (direct expectorate, n=30). All controls were prepared using the H.2 protocol. Results revealed 100% concordance of MTB/RIF results for all except the low-positive group in the H.1 study arm (n=10; 88% concordance). OM-S-treated sputa were successful in both protocols; if the Xpert buffer is not added during the H.2 procedure, sample viscosity may require repeat testing. Using OM-S could offer users flexibility in clinical testing algorithms. Larger compatibility studies are warranted, particularly with respect to MTB/RIF results for low-positive samples. Copyright © 2016 Elsevier Inc. All rights reserved.
Datta, Naomi; Olarte, J.
1974-01-01
All 17 Salmonella typhi strains tested from the epidemic in Mexico carried R factors of compatibility group H, conferring resistance to chloramphenicol, streptomycin, tetracycline, and sulfonamides. Some S. typhi strains carried, in addition, non-conjugative, ampicillin resistance plasmids and R factors of the I or A–C complex. All 20 Shigella dysenteriae 1 strains tested of epidemic origin carried O-group R factors. Ampicillin resistance in S. dysenteriae 1 was not proved to be plasmid borne. R factors of group H were not identified in any of the tested Mexican isolates other than S. typhi, but R factors of group O were identified in Escherichia coli, Shigella flexneri, and one strain of S. typhi, as well as in the epidemic S. dysenteriae. An R factor was identified which seemed to have two compatibility specificities, groups Iω and O. PMID:4599123
Earth's Outer Core Properties Estimated Using Bayesian Inversion of Normal Mode Eigenfrequencies
NASA Astrophysics Data System (ADS)
Irving, J. C. E.; Cottaar, S.; Lekic, V.
2016-12-01
The outer core is arguably Earth's most dynamic region, and consists of an iron-nickel liquid with an unknown combination of lighter alloying elements. Frequencies of Earth's normal modes provide the strongest constraints on the radial profiles of compressional wavespeed, VΦ, and density, ρ, in the outer core. Recent great earthquakes have yielded new normal mode measurements; however, mineral physics experiments and calculations are often compared to the Preliminary reference Earth model (PREM), which is 35 years old and does not provide uncertainties. Here we investigate the thermo-elastic properties of the outer core using Earth's free oscillations and a Bayesian framework. To estimate radial structure of the outer core and its uncertainties, we choose to exploit recent datasets of normal mode centre frequencies. Under the self-coupling approximation, centre frequencies are unaffected by lateral heterogeneities in the Earth, for example in the mantle. Normal modes are sensitive to both VΦ and ρ in the outer core, with each mode's specific sensitivity depending on its eigenfunctions. We include a priori bounds on outer core models that ensure compatibility with measurements of mass and moment of inertia. We use Bayesian Monte Carlo Markov Chain techniques to explore different choices in parameterizing the outer core, each of which represents different a priori constraints. We test how results vary (1) assuming a smooth polynomial parametrization, (2) allowing for structure close to the outer core's boundaries, (3) assuming an Equation-of-State and adiabaticity and inverting directly for thermo-elastic parameters. In the second approach we recognize that the outer core may have distinct regions close to the core-mantle and inner core boundaries and investigate models which parameterize the well mixed outer core separately from these two layers. In the last approach we seek to map the uncertainties directly into thermo-elastic parameters including the bulk modulus, its pressure derivative, and molar mass and volume, with particular attention paid to the (inherent) trade-offs between the different coefficients. We discuss our results in terms of added uncertainty to the light element composition of the outer core and the potential existence of anomalous structure near the outer core's boundaries.
compare the effects of elevated temperature on 801-finish glass. The strength qualities at 75 F of Owens - Corning ECG-140 continuous-filament roving glass...with an 801 epoxy compatible finish and the same glass with an HTS epoxy compatible finish were tested. The strength qualities of Owens - Corning ECG
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chou, Y. S.; Stevenson, Jeffry W.; Choi, Jung-Pyung
2013-01-01
A generic solid oxide fuel cell (SOFC) test fixture was developed to evaluate candidate materials under realistic conditions. A commerical 50 mm x 50 mm NiO-YSZ anode supported thin YSZ electrolyte cell with lanthanum strontium manganite (LSM) cathode was tested to evaluate the stability of candidate materials. The cell was tested in two stages at 800oC: stage I of low (~3% H2O) humidity and stage II of high (~30% H2O) humidity hydrogen fuel at constant voltage or constant current mode. Part I of the work was published earlier with information of the generic test fixture design, materials, cell performance, andmore » optical post-mortem analysis. In part II, detailed microstructure and interfacial characterizations are reported regarding the SOFC candidate materials: (Mn,Co)-spinel conductive coating, alumina coating for sealing area, ferritic stainless steel interconnect, refractory sealing glass, and their interactions with each other. Overall, the (Mn,Co)-spinel coating was very effective in minimizing Cr migration. No Cr was identified in the cathode after 1720h at 800oC. Aluminization of metallic interconnect also proved to be chemically compatible with alkaline-earth silicate sealing glass. The details of interfacial reaction and microstructure development are discussed.« less
NASA Astrophysics Data System (ADS)
Geng, Ying; Li, Shenping; Li, Ming-Jun; Sutton, Clifford G.; McCollum, Robert L.; McClure, Randy L.; Koklyushkin, Alexander V.; Matthews, Karen I.; Luther, James P.; Butler, Douglas L.
2015-03-01
A complete single mode dual-core fiber system for short-reach optical interconnects is fabricated and tested for high-speed data transmission. It includes dual-core fibers capable of bi-directional data transmission, dual-core simplex LC connectors, and fan-outs. The transmission system offers simplified bi-directional traffic engineering with integrated bidirectional transceivers and compact system design, utilizing simplex dual-core LC connectors that use half the space while increasing the bandwidth density by a factor of two. The fiber has two cores that are compatible with single mode fiber and conforms to the industry standard outer diameter of 125 μm. This reduces operational complexity by reducing the size and number of fibers, cables and connectors. Measured OTDR loss for both cores was 0.34 dB/km at 1310 nm and 0.19 dB/km at 1550 nm. Crosstalk for a piece of 5.8 km long dual-core fiber was measured to be below -75 dB at 1310 nm, and below -40 dB at 1550 nm. Both free-space optics fan-outs and tapered-fiber-coupler based MCF fan-outs were evaluated for the transmission system. Error-free and penalty-free 25 Gb/s bi-directional transmission performance was demonstrated for three different fiber lengths, 200 m, 2 km and 10 km, using the complete all-fiber-based system including connectors and fan-outs. This single mode, dual-core fiber transmission system adds complementary value to systems where additional increases in bandwidth density can come from wavelength division multiplexing and multiple bits per symbol.
Detergent-compatible proteases: microbial production, properties, and stain removal analysis.
Niyonzima, Francois Niyongabo; More, Sunil
2015-01-01
Proteases are one of the most important commercial enzymes used in various industrial domains such as detergent and leather industries. The alkaline proteases as well as other detergent-compatible enzymes such as lipases and amylases serve now as the key components in detergent formulations. They break down various stains during fabric washing. The search for detergent-compatible proteases with better properties is a continuous exercise. The current trend is to use detergent-compatible proteases that are stable over a wide temperature range. Although the proteases showing stability at elevated pH have the capacity to be used in detergent formulations, their usage can be significant if they are also stable and compatible with detergent and detergent ingredients, and also able to remove protein stains. Despite the existence of some reviews on alkaline proteases, there is no specification for the use of alkaline proteases as detergent additives. The present review describes the detergent-compatible proteases tested as detergent additives. An overview was provided for screening, optimization, purification, and properties of detergent compatible proteases, with an emphasis on the stability and compatibility of the alkaline proteases with the detergent and detergent compounds, as well as stain removal examination methods.
Chang, Ye; Hui, Zhipeng; Wang, Xiayu; Qu, Hemi; Pang, Wei
2018-01-01
In this paper, we develop a novel dual-mode gas sensor system which comprises a silicon nanoribbon field effect transistor (Si-NR FET) and a film bulk acoustic resonator (FBAR). We investigate their sensing characteristics using polar and nonpolar organic compounds, and demonstrate that polarity has a significant effect on the response of the Si-NR FET sensor, and only a minor effect on the FBAR sensor. In this dual-mode system, qualitative discrimination can be achieved by analyzing polarity with the Si-NR FET and quantitative concentration information can be obtained using a polymer-coated FBAR with a detection limit at the ppm level. The complementary performance of the sensing elements provides higher analytical efficiency. Additionally, a dual mixture of two types of freons (CFC-113 and HCFC-141b) is further analyzed with the dual-mode gas sensor. Owing to the small size and complementary metal-oxide semiconductor (CMOS)-compatibility of the system, the dual-mode gas sensor shows potential as a portable integrated sensing system for the analysis of gas mixtures in the future. PMID:29370109
Chang, Ye; Hui, Zhipeng; Wang, Xiayu; Qu, Hemi; Pang, Wei; Duan, Xuexin
2018-01-25
In this paper, we develop a novel dual-mode gas sensor system which comprises a silicon nanoribbon field effect transistor (Si-NR FET) and a film bulk acoustic resonator (FBAR). We investigate their sensing characteristics using polar and nonpolar organic compounds, and demonstrate that polarity has a significant effect on the response of the Si-NR FET sensor, and only a minor effect on the FBAR sensor. In this dual-mode system, qualitative discrimination can be achieved by analyzing polarity with the Si-NR FET and quantitative concentration information can be obtained using a polymer-coated FBAR with a detection limit at the ppm level. The complementary performance of the sensing elements provides higher analytical efficiency. Additionally, a dual mixture of two types of freons (CFC-113 and HCFC-141b) is further analyzed with the dual-mode gas sensor. Owing to the small size and complementary metal-oxide semiconductor (CMOS)-compatibility of the system, the dual-mode gas sensor shows potential as a portable integrated sensing system for the analysis of gas mixtures in the future.
A high specific power solar array for low to mid-power spacecraft
NASA Technical Reports Server (NTRS)
Jones, P. Alan; White, Stephen F.; Harvey, T. Jeffery; Smith, Brian S.
1993-01-01
UltraFlex is the generic term for a solar array system which delivers on-orbit power in the 400 to 6,000 watt per wing sizes with end-of-life specific power performance ranging to 150 watts-per-kilogram. Such performance is accomplished with off-the-shelf solar cells and state-of the-art materials and processes. Much of the recent work in photovoltaics is centered on advanced solar cell development. Successful as such work has been, no integrated solar array system has emerged which meets NASA's stated goals of 'increasing the end-of-life performance of space solar cells and arrays while minimizing their mass and cost.' This issue is addressed; namely, is there an array design that satisfies the usual requirements for space-rated hardware and that is inherently reliable, inexpensive, easily manufactured and simple, which can be used with both advanced cells currently in development and with inexpensive silicon cells? The answer is yes. The UltraFlex array described incorporates use of a blanket substrate which is thermally compatible with silicon and other materials typical of advanced multi-junction devices. The blanket materials are intrinsically insensitive to atomic oxygen degradation, are space rated, and are compatible with standard cell bonding processes. The deployment mechanism is simple and reliable and the structure is inherently stiff (high natural frequency). Mechanical vibration modes are also readily damped. The basic design is presented as well as supporting analysis and development tests.
A high specific power solar array for low to mid-power spacecraft
NASA Astrophysics Data System (ADS)
Jones, P. Alan; White, Stephen F.; Harvey, T. Jeffery; Smith, Brian S.
1993-05-01
UltraFlex is the generic term for a solar array system which delivers on-orbit power in the 400 to 6,000 watt per wing sizes with end-of-life specific power performance ranging to 150 watts-per-kilogram. Such performance is accomplished with off-the-shelf solar cells and state-of the-art materials and processes. Much of the recent work in photovoltaics is centered on advanced solar cell development. Successful as such work has been, no integrated solar array system has emerged which meets NASA's stated goals of 'increasing the end-of-life performance of space solar cells and arrays while minimizing their mass and cost.' This issue is addressed; namely, is there an array design that satisfies the usual requirements for space-rated hardware and that is inherently reliable, inexpensive, easily manufactured and simple, which can be used with both advanced cells currently in development and with inexpensive silicon cells? The answer is yes. The UltraFlex array described incorporates use of a blanket substrate which is thermally compatible with silicon and other materials typical of advanced multi-junction devices. The blanket materials are intrinsically insensitive to atomic oxygen degradation, are space rated, and are compatible with standard cell bonding processes. The deployment mechanism is simple and reliable and the structure is inherently stiff (high natural frequency). Mechanical vibration modes are also readily damped. The basic design is presented as well as supporting analysis and development tests.
Phonon Enhancement of Electronic and Optoelectronic Devices
2006-12-01
wave vector q determines the momentum transfer in the electron transition. Inasmuch as the polar mode confinement has not yet been studied in the InAs...and the geometry is compatible with the TM polarization of intersubband transitions. Due to the shallow skin depth in the metal (several hundred A...noise temperature ofa-1400 K is among the lowest at this high frequency. Figure 6 shows the schematic and measurement results of frequency locking of a
A feasibility study of unmanned rendezvous and docking in Mars orbit: Midterm review
NASA Technical Reports Server (NTRS)
1974-01-01
The ascent, rendezvous, docking and sample transfer operations in a potential MSSR mission that uses the Mars orbital rendezvous mode are considered. In order that the design choices made for these operations remain compatible with the rest of the mission, the impact on the Earth launch, Mars landing and orbiting and Earth return phase are also being assessed. The selection and description of a preliminary baseline concept are presented.
2015-12-01
AEHF satellites and MILSTAR satellites in the backwards-compatible mode. Mission requirements specific to Navy operations, including threat levels and...Center for Cost Analysis (NCCA) Component Cost Position (CCP) memo dated December 18, 2015 Confidence Level Confidence Level of cost estimate for... Econ Qty Sch Eng Est Oth Spt Total 6.970 0.082 0.637 0.034 0.000 -1.210 0.000 -0.418 -0.875 6.095 Current SAR Baseline to Current Estimate (TY $M) PAUC
[Experience in the use of equipment for ECG system analysis in municipal polyclinics].
Bondarenko, A A
2006-01-01
Two electrocardiographs, an analog-digital electrocardiograph with preliminary analog filtering of signal and a smart cardiograph implemented as a PC-compatible device without preliminary analog filtering, are considered. Advantages and disadvantages of ECG systems based on artificial intelligence are discussed. ECG interpretation modes provided by the two electrocardiographs are considered. The reliability of automatic ECG interpretation is assessed. Problems of rational use of automated ECG processing systems are discussed.
NASA Astrophysics Data System (ADS)
Delabie, E.; Hillesheim, J. C.; Mailloux, J.; Maggi, C. F.; Rimini, F.; Solano, E. R.; JET contributors Team
2016-10-01
The threshold power to access H-mode on JET-ILW has a minimum as function of density. Power ramps in the low and high density branch show qualitatively very different behavior above threshold. In the high density branch, edge density and temperature abruptly increase after the L-H transition, and the plasma evolves into a type I ELMy H-mode. Transitions in the low density branch are gradual and lead to the formation of a temperature pedestal, without increase in edge density. These characteristics are reminiscent of the I-mode regime, but with high frequency ELM activity. The small ELMs allow stable H-mode operation with tolerable tungsten contamination, as long as both density and power stay below the type I ELM boundary. The density range in which the low density branch can be accessed scales favourably with toroidal field but unfavourably with isotope mass. At BT=3.4T, a stable H-mode has been obtained at
Neighboring block based disparity vector derivation for multiview compatible 3D-AVC
NASA Astrophysics Data System (ADS)
Kang, Jewon; Chen, Ying; Zhang, Li; Zhao, Xin; Karczewicz, Marta
2013-09-01
3D-AVC being developed under Joint Collaborative Team on 3D Video Coding (JCT-3V) significantly outperforms the Multiview Video Coding plus Depth (MVC+D) which simultaneously encodes texture views and depth views with the multiview extension of H.264/AVC (MVC). However, when the 3D-AVC is configured to support multiview compatibility in which texture views are decoded without depth information, the coding performance becomes significantly degraded. The reason is that advanced coding tools incorporated into the 3D-AVC do not perform well due to the lack of a disparity vector converted from the depth information. In this paper, we propose a disparity vector derivation method utilizing only the information of texture views. Motion information of neighboring blocks is used to determine a disparity vector for a macroblock, so that the derived disparity vector is efficiently used for the coding tools in 3D-AVC. The proposed method significantly improves a coding gain of the 3D-AVC in the multiview compatible mode about 20% BD-rate saving in the coded views and 26% BD-rate saving in the synthesized views on average.
Dielectric Covered Planar Antennas
NASA Technical Reports Server (NTRS)
Llombart Juan, Nuria (Inventor); Lee, Choonsup (Inventor); Chattopadhyay, Goutam (Inventor); Gill, John J. (Inventor); Skalare, Anders J. (Inventor); Siegel, Peter H. (Inventor)
2014-01-01
An antenna element suitable for integrated arrays at terahertz frequencies is disclosed. The antenna element comprises an extended spherical (e.g. hemispherical) semiconductor lens, e.g. silicon, antenna fed by a leaky wave waveguide feed. The extended spherical lens comprises a substantially spherical lens adjacent a substantially planar lens extension. A couple of TE/TM leaky wave modes are excited in a resonant cavity formed between a ground plane and the substantially planar lens extension by a waveguide block coupled to the ground plane. Due to these modes, the primary feed radiates inside the lens with a directive pattern that illuminates a small sector of the lens. The antenna structure is compatible with known semiconductor fabrication technology and enables production of large format imaging arrays.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wan, Yating; Li, Qiang; Lau, Kei May, E-mail: eekmlau@ust.hk
2016-07-04
Temperature characteristics of optically pumped micro-disk lasers (MDLs) incorporating InAs quantum dot active regions are investigated for on-chip light sources. The InAs quantum dot MDLs were grown on V-groove patterned (001) silicon, fully compatible with the prevailing complementary metal oxide-semiconductor technology. By combining the high-quality whispering gallery modes and 3D confinement of injected carriers in quantum dot micro-disk structures, we achieved lasing operation from 10 K up to room temperature under continuous optical pumping. Temperature dependences of the threshold, lasing wavelength, slope efficiency, and mode linewidth are examined. An excellent characteristic temperature T{sub o} of 105 K has been extracted.
NASA Astrophysics Data System (ADS)
Levi, Assi; Mumcuoglu, Kosta Y.; Ingber, Arieh; Enk, Claes D.
2012-06-01
Scabies is an intensely pruritic disorder induced by a delayed type hypersensitivity reaction to infestation of the skin by the mite Sarcoptes scabiei. The diagnosis of scabies is established clinically and confirmed by identifying mites or eggs by microscopic examination of scrapings from the skin or by surface microscopy using a dermatoscope. Reflectance-mode confocal microscopy is a novel technique used for noninvasive imaging of skin structures and lesions at a resolution compatible to that of conventional histology. Recently, the technique was employed for the confirmation of the clinical diagnosis of scabies. We demonstrate the first ever documentation of a larva moving freely inside the skin of a patient infected with scabies.
NASA Astrophysics Data System (ADS)
Itobe, Hiroki; Nakagawa, Yosuke; Mizumoto, Yuta; Kangawa, Hiroi; Kakinuma, Yasuhiro; Tanabe, Takasumi
2016-05-01
We fabricated a calcium fluoride (CaF2) whispering gallery mode (WGM) microcavity with a computer controlled ultra-precision cutting process. We observed a thermo-opto-mechanical (TOM) oscillation in the CaF2 WGM microcavity, which may influence the stability of the optical output when the cavity is employed for Kerr comb generation. We studied experimentally and numerically the mechanism of the TOM oscillation and showed that it is strongly dependent on cavity diameter. In addition, our numerical study suggests that a microcavity structure fabricated with a hybrid material (i.e. CaF2 and silicon), which is compatible with an ultra-high Q and high thermal conductivity, will allow us to reduce the TOM oscillation and stabilize the optical output.
An instability of hyperbolic space under the Yang-Mills flow
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gegenberg, Jack; Day, Andrew C.; Liu, Haitao
2014-04-15
We consider the Yang-Mills flow on hyperbolic 3-space. The gauge connection is constructed from the frame-field and (not necessarily compatible) spin connection components. The fixed points of this flow include zero Yang-Mills curvature configurations, for which the spin connection has zero torsion and the associated Riemannian geometry is one of constant curvature. We analytically solve the linearized flow equations for a large class of perturbations to the fixed point corresponding to hyperbolic 3-space. These can be expressed as a linear superposition of distinct modes, some of which are exponentially growing along the flow. The growing modes imply the divergence ofmore » the (gauge invariant) perturbative torsion for a wide class of initial data, indicating an instability of the background geometry that we confirm with numeric simulations in the partially compactified case. There are stable modes with zero torsion, but all the unstable modes are torsion-full. This leads us to speculate that the instability is induced by the torsion degrees of freedom present in the Yang-Mills flow.« less
Julstrom, Stephen; Kozma-Spytek, Linda; Isabelle, Scott
2011-09-01
In the development of the requirements for telecoil-compatible magnetic signal sources for wireless and cordless telephones to be specified in the American National Standards Institute (ANSI) C63.19 and ANSI/Telecommunications Industry Association-1083 compatibility standards, it became evident that additional data concerning in-the-field telecoil use and subjective preferences were needed. Primarily, the magnetic signal levels and, secondarily, the field orientations required for effective and comfortable telecoil use with wireless and cordless handsets needed further characterization. (A companion article addresses user signal-to-noise needs and preferences.) Test subjects used their own hearing aids, which were addressed with both a controlled acoustic speech source and a controlled magnetic speech source. Each subject's hearing aid was first measured to find the telecoil's magnetic field orientation for maximum response, and an appropriate large magnetic head-worn coil was selected to apply the magnetic signal. Subjects could control the strength of the magnetic signal, first to match the loudness of a reference acoustic signal and then to find their Most Comfortable Level (MCL). The subjective judgments were compared against objective in-ear probe tube level measurements. The 57 test subjects covered an age range of 22 to 79 yr, with a self-reported hearing loss duration of 12 to 72 yr. All had telecoils that they used for at least some telecommunications needs. The self-reported degree of hearing loss ranged from moderate to profound. A total of 69 hearing aids were surveyed for their telecoil orientation. A guided intake questionnaire yielded general background information for each subject. A custom-built test jig enabled hearing aid telecoil orientation within the aid to be determined. By comparing this observation with the in-use hearing aid position, the in-use orientation for each telecoil was determined. A custom-built test control box fed by prepared speech recordings from computer files enabled the tester to switch between acoustic and magnetic speech signals and to read and record the subject's selected magnetic level settings. The overwhelming majority of behind-the-ear aids tested exhibited in-use telecoil orientations that were substantially vertical. An insufficient number of participants used in-the-ear aids to be able to draw general conclusions concerning the telecoil orientations of this style aid. The subjects showed a generally consistent preference for telecoil speech levels that subjectively matched the level that they heard from 65 dB SPL acoustic speech. The magnetic level needed to achieve their MCL, however, varied over a 30 dB range. Producing the necessary magnetic field strengths from a wireless or cordless telephone's handset in an in-use vertical orientation is vital for compatibility with the vast majority of behind-the-ear aids. Due to the very wide range of preferred magnetic signal levels shown, only indirect conclusions can be drawn concerning required signal levels. The strong preference for a 65 dB SPL equivalent level can be combined with established standards addressing hearing aid performance to derive reasonable source level requirements. Greater consistency between in-the-field hearing aid telecoil and microphone sensitivity adjustments could yield improved results for some users. American Academy of Audiology.
Gionfriddo, Emanuela; Souza-Silva, Érica A; Pawliszyn, Janusz
2015-08-18
This work aims to investigate the behavior of analytes in complex mixtures and matrixes with the use of solid-phase microextraction (SPME). Various factors that influence analyte uptake such as coating chemistry, extraction mode, the physicochemical properties of analytes, and matrix complexity were considered. At first, an aqueous system containing analytes bearing different hydrophobicities, molecular weights, and chemical functionalities was investigated by using commercially available liquid and solid porous coatings. The differences in the mass transfer mechanisms resulted in a more pronounced occurrence of coating saturation in headspace mode. Contrariwise, direct immersion extraction minimizes the occurrence of artifacts related to coating saturation and provides enhanced extraction of polar compounds. In addition, matrix-compatible PDMS-modified solid coatings, characterized by a new morphology that avoids coating fouling, were compared to their nonmodified analogues. The obtained results indicate that PDMS-modified coatings reduce artifacts associated with coating saturation, even in headspace mode. This factor, coupled to their matrix compatibility, make the use of direct SPME very practical as a quantification approach and the best choice for metabolomics studies where wide coverage is intended. To further understand the influence on analyte uptake on a system where additional interactions occur due to matrix components, ex vivo and in vivo sampling conditions were simulated using a starch matrix model, with the aim of mimicking plant-derived materials. Our results corroborate the fact that matrix handling can affect analyte/matrix equilibria, with consequent release of high concentrations of previously bound hydrophobic compounds, potentially leading to coating saturation. Direct immersion SPME limited the occurrence of the artifacts, which confirms the suitability of SPME for in vivo applications. These findings shed light into the implementation of in vivo SPME strategies in quantitative metabolomics studies of complex plant-based systems.
From GeoSTEP to MidiSTEP: a small satellite experiment to test the equivalence principle
NASA Astrophysics Data System (ADS)
Bonneville, R.
1996-11-01
Testing the equivalence principle (EP) has been recognized by the scientific community as a short term prime objective for fundamental physics in space. In 1994 a phase 0/A study of the GeoSTEP mission was initiated by CNES in order to design a space experiment to test the EP at the accuracy of 0264-9381/13/11A/020/img1, with the concern to be compatible with the small versatile platform `PROTEUS' under study. The GeoSTEP payload includes a set of four differential accelerometers placed at cryogenic temperature on board a drag-free, three-axis stabilized satellite in low-Earth orbit. Each accelerometer contains a pair of test masses A - A, A - B, A - C, B - C (inner mass - outer mass) made of three different materials A, B, C with decreasing densities. The accelerometer concept is the fully electrostatic levitation and read-out device proposed by ONERA (`SAGE'). The drag-free and attitude control system (DFACS) is monitored by the common mode data of the accelerometers along their three axes, while the expected violation signal is detected by the differential mode data along the longitudinal sensitive axis. The cryostat is a single chamber supercritical helium dewar designed by CEA. Helium boiling off from the dewar feeds a set of proportional gas thrusters performing the DFCAS. Error analysis and data processing preparation is managed by OCA/CERGA. The satellite will be on a 6 am - 6 pm near polar, near circular, Sun-synchronous orbit, at an altitude of 600 to 900 km, depending upon the atmosphere density at the launch date. The mission will last at least 4 months and could be launched in 2002. A descoped, room-temperature version of the project using electric thrusters (FEEPs) and called MidiSTEP has also been considered.
Brain-Compatible Assessments. Second Edition
ERIC Educational Resources Information Center
Ronis, Diane L.
2007-01-01
Diane Ronis, a recognized expert in brain-compatible learning and assessment, goes beyond the world of standardized testing to show educators how to build and use targeted assessments based on the latest neuroscientific research. Updated to reflect recent findings about how the brain learns, this book provides readers with revised tools for…
USDA-ARS?s Scientific Manuscript database
The objectives were to evaluate the efficiency of entomopathogenic fungi against Plutella xylostella (L.) and the compatibility of the most virulent isolates with some of the insecticides registered for use on cabbage crops. Pathogenicity tests used isolates of Beauveria bassiana, Metarhizium rileyi...
2012-01-01
Background Magnetic resonance imaging (MRI) is an important tool for cardiac research, and it is frequently used for resting cardiac assessments. However, research into non-pharmacological stress cardiac evaluation is limited. Methods We aimed to design a portable and relatively inexpensive MRI cycle ergometer capable of continuously measuring pedalling workload while patients exercise to maintain target heart rates. Results We constructed and tested an MRI-compatible cycle ergometer for a 1.5 T MRI scanner. Resting and sub-maximal exercise images (at 110 beats per minute) were successfully obtained in 8 healthy adults. Conclusions The MRI-compatible cycle ergometer constructed by our research group enabled cardiac assessments at fixed heart rates, while continuously recording power output by directly measuring pedal force and crank rotation. PMID:22423637
NASA Technical Reports Server (NTRS)
Valdez, A.
1999-01-01
This document contains the procedure and the test results of the Advanced Microwave Sounding Unit-A (AMSU-A) Electromagnetic Interference (EMI), Electromagnetic Susceptibility, and Electromagnetic Compatibility (EMC) qualification test for the Meteorological Satellite (METSAT) and the Meteorological Operation Platform (METOP) projects. The test was conducted in accordance with the approved EMI/EMC Test Plan/Procedure, Specification number AE-26151/5D. This document describes the EMI/EMC test performed by Aerojet and it is presented in the following manner: Section-1 contains introductory material and a brief summary of the test results. Section 2 contains more detailed descriptions of the test plan, test procedure, and test results for each type of EMI/EMC test conducted. Section 3 contains supplementary information that includes test data sheets, plots, and calculations collected during the qualification testing.
Electromagnetic Compatibility Testing Studies
NASA Technical Reports Server (NTRS)
Trost, Thomas F.; Mitra, Atindra K.
1996-01-01
This report discusses the results on analytical models and measurement and simulation of statistical properties from a study of microwave reverberation (mode-stirred) chambers performed at Texas Tech University. Two analytical models of power transfer vs. frequency in a chamber, one for antenna-to-antenna transfer and the other for antenna to D-dot sensor, were experimentally validated in our chamber. Two examples are presented of the measurement and calculation of chamber Q, one for each of the models. Measurements of EM power density validate a theoretical probability distribution on and away from the chamber walls and also yield a distribution with larger standard deviation at frequencies below the range of validity of the theory. Measurements of EM power density at pairs of points which validate a theoretical spatial correlation function on the chamber walls and also yield a correlation function with larger correlation length, R(sub corr), at frequencies below the range of validity of the theory. A numerical simulation, employing a rectangular cavity with a moving wall shows agreement with the measurements. The determination that the lowest frequency at which the theoretical spatial correlation function is valid in our chamber is considerably higher than the lowest frequency recommended by current guidelines for utilizing reverberation chambers in EMC testing. Two suggestions have been made for future studies related to EMC testing.
Li, Jing-Jing; Gao, Qi; Liu, Zhi-Dong; Kang, Qiong-Hua; Hou, Yi-Jun; Zhang, Luo-Chuan; Hu, Xiao-Mei; Li, Jie; Zhang, Juan
2015-01-01
Internal quality control (IQC) is a critical component of laboratory quality management, and IQC products can determine the reliability of testing results. In China, given the fact that most blood transfusion compatibility laboratories do not employ IQC products or do so minimally, there is a lack of uniform and standardized IQC methods. To explore the reliability of IQC products and methods, we studied 697 results from IQC samples in our laboratory from 2012 to 2014. The results showed that the sensitivity and specificity of the IQCs in anti-B testing were 100% and 99.7%, respectively. The sensitivity and specificity of the IQCs in forward blood typing, anti-A testing, irregular antibody screening, and cross-matching were all 100%. The reliability analysis indicated that 97% of anti-B testing results were at a 99% confidence level, and 99.9% of forward blood typing, anti-A testing, irregular antibody screening, and cross-matching results were at a 99% confidence level. Therefore, our IQC products and methods are highly sensitive, specific, and reliable. Our study paves the way for the establishment of a uniform and standardized IQC method for pre-transfusion compatibility testing in China and other parts of the world. PMID:26488582
NASA Astrophysics Data System (ADS)
Zhu, Zhongyunshen; Song, Yuxin; Zhang, Zhenpu; Sun, Hao; Han, Yi; Li, Yaoyao; Zhang, Liyao; Xue, Zhongying; Di, Zengfeng; Wang, Shumin
2017-09-01
We demonstrate Au-assisted vapor-solid-solid (VSS) growth of Ge nanowires (NWs) by molecular beam epitaxy at the substrate temperature of ˜180 °C, which is compatible with the temperature window for Si-based integrated circuit. Low temperature grown Ge NWs hold a smaller size, similar uniformity, and better fit with Au tips in diameter, in contrast to Ge NWs grown at around or above the eutectic temperature of Au-Ge alloy in the vapor-liquid-solid (VLS) growth. Six ⟨110⟩ growth orientations were observed on Ge (110) by the VSS growth at ˜180 °C, differing from only one vertical growth direction of Ge NWs by the VLS growth at a high temperature. The evolution of NWs dimension and morphology from the VLS growth to the VSS growth is qualitatively explained by analyzing the mechanism of the two growth modes.
Apollo-Soyuz test project docking system
NASA Technical Reports Server (NTRS)
Swan, W. L., Jr.
1976-01-01
The United States and Soviet Union in July 1975 successfully completed a joint space mission utilizing each country's spacecraft and the compatible docking system designed and fabricated by each country. The compatible docking system is described, along with the extensive research, development, and testing leading up to the successful mission. It also describes the formulation and implementation of methods for breaking the language barrier, bridging the extensive distances for communication and travel, and adjusting to each country's different culture during the three-year development program.
NASA Technical Reports Server (NTRS)
Faget, N. M.
1986-01-01
Attention is given to results obtained to date in developmental investigations of a thermal energy storage (TES) system for the projected NASA Space Station's solar dynamic power system; these tests have concentrated on issues related to materials compatibility for phase change materials (PCMs) and their containment vessels' materials. The five PCMs tested have melting temperatures that correspond to the operating temperatures of either the Brayton or Rankine heat engines, which were independently chosen for their high energy densities.
Extending the physics basis of quiescent H-mode toward ITER relevant parameters
Solomon, W. M.; Burrell, K. H.; Fenstermacher, M. E.; ...
2015-06-26
Recent experiments on DIII-D have addressed several long-standing issues needed to establish quiescent H-mode (QH-mode) as a viable operating scenario for ITER. In the past, QH-mode was associated with low density operation, but has now been extended to high normalized densities compatible with operation envisioned for ITER. Through the use of strong shaping, QH-mode plasmas have been maintained at high densities, both absolute (more » $$\\bar{n}$$ e ≈ 7 × 10 19 m ₋3) and normalized Greenwald fraction ($$\\bar{n}$$ e/n G > 0.7). In these plasmas, the pedestal can evolve to very high pressure and edge current as the density is increased. High density QH-mode operation with strong shaping has allowed access to a previously predicted regime of very high pedestal dubbed “Super H-mode”. Calculations of the pedestal height and width from the EPED model are quantitatively consistent with the experimentally observed density evolution. The confirmation of the shape dependence of the maximum density threshold for QH-mode helps validate the underlying theoretical model of peeling- ballooning modes for ELM stability. In general, QH-mode is found to achieve ELM- stable operation while maintaining adequate impurity exhaust, due to the enhanced impurity transport from an edge harmonic oscillation, thought to be a saturated kink- peeling mode driven by rotation shear. In addition, the impurity confinement time is not affected by rotation, even though the energy confinement time and measured E×B shear are observed to increase at low toroidal rotation. Together with demonstrations of high beta, high confinement and low q 95 for many energy confinement times, these results suggest QH-mode as a potentially attractive operating scenario for the ITER Q=10 mission.« less
Iwano, Megumi; Igarashi, Motoko; Tarutani, Yoshiaki; Kaothien-Nakayama, Pulla; Nakayama, Hideki; Moriyama, Hideki; Yakabe, Ryo; Entani, Tetsuyuki; Shimosato-Asano, Hiroko; Ueki, Masao; Tamiya, Gen; Takayama, Seiji
2014-01-01
In the Brassicaceae, intraspecific non-self pollen (compatible pollen) can germinate and grow into stigmatic papilla cells, while self-pollen or interspecific pollen is rejected at this stage. However, the mechanisms underlying this selective acceptance of compatible pollen remain unclear. Here, using a cell-impermeant calcium indicator, we showed that the compatible pollen coat contains signaling molecules that stimulate Ca2+ export from the papilla cells. Transcriptome analyses of stigmas suggested that autoinhibited Ca2+-ATPase13 (ACA13) was induced after both compatible pollination and compatible pollen coat treatment. A complementation test using a yeast Saccharomyces cerevisiae strain lacking major Ca2+ transport systems suggested that ACA13 indeed functions as an autoinhibited Ca2+ transporter. ACA13 transcription increased in papilla cells and in transmitting tracts after pollination. ACA13 protein localized to the plasma membrane and to vesicles near the Golgi body and accumulated at the pollen tube penetration site after pollination. The stigma of a T-DNA insertion line of ACA13 exhibited reduced Ca2+ export, as well as defects in compatible pollen germination and seed production. These findings suggest that stigmatic ACA13 functions in the export of Ca2+ to the compatible pollen tube, which promotes successful fertilization. PMID:24569769
Moscoso-Mártir, Alvaro; Müller, Juliana; Islamova, Elmira; Merget, Florian; Witzens, Jeremy
2017-09-20
Based on the single channel characterization of a Silicon Photonics (SiP) transceiver with Semiconductor Optical Amplifier (SOA) and semiconductor Mode-Locked Laser (MLL), we evaluate the optical power budget of a corresponding Wavelength Division Multiplexed (WDM) link in which penalties associated to multi-channel operation and the management of polarization diversity are introduced. In particular, channel cross-talk as well as Cross Gain Modulation (XGM) and Four Wave Mixing (FWM) inside the SOA are taken into account. Based on these link budget models, the technology is expected to support up to 12 multiplexed channels without channel pre-emphasis or equalization. Forward Error Correction (FEC) does not appear to be required at 14 Gbps if the SOA is maintained at 25 °C and MLL-to-SiP as well as SiP-to-SOA interface losses can be maintained below 3 dB. In semi-cooled operation with an SOA temperature below 55 °C, multi-channel operation is expected to be compatible with standard 802.3bj Reed-Solomon FEC at 14 Gbps provided interface losses are maintained below 4.5 dB. With these interface losses and some improvements to the Transmitter (Tx) and Receiver (Rx) electronics, 25 Gbps multi-channel operation is expected to be compatible with 7% overhead hard decision FEC.
Inheritance of proportionate dwarfism in Angus cattle.
Latter, M R; Latter, B D H; Wilkins, J F; Windsor, P A
2006-04-01
To determine the mode of inheritance of congenital proportionate dwarfism in Angus and Angus crossbred cattle, initially detected in two commercial beef herds in northern New South Wales. Matings of normal carrier sires to unrelated cows of diverse breeds, and of one carrier sire to his unaffected daughters. An unrelated Piedmontese bull was also mated to unaffected daughters of the carrier sires. Two carrier Angus bulls and nine unaffected daughters, all of whom were completely indistinguishable from normal animals, were purchased for controlled breeding studies under known nutritional and disease conditions. Affected and carrier individuals were examined for the presence of obvious chromosomal abnormalities. Angus dwarfism has been successfully reproduced under controlled experimental conditions over successive years using unrelated dams and is undoubtedly heritable. The high frequency of occurrence of affected individuals (23/61 = 0.38 +/- .06) among the progeny of matings of the Angus sires to unrelated females of diverse breeding is not compatible with recessive inheritance, because of the negligible frequency of proportionate dwarfism in the breeds of the dams. Both paternal and maternal transmission of the defect was demonstrated, so that imprinting in the strict sense of a gene that is only expressed when received from the male parent appears not to be involved. Tested individuals showed no evidence of gross chromosomal abnormality. Dominant autosomal inheritance with incomplete penetrance was indicated by the lack of expression of the defective gene in the two Angus sires and in three unaffected daughters who produced dwarf calves from matings to the Piedmontese bull. The mode of inheritance is that of a single autosomal dominant gene with a penetrance coefficient of 0.75 +/- 0.12, estimated from the observed incidence of 23/61 affected offspring of the two carrier Angus bulls mated to unrelated dams. Simple genetic models involving either (i) an unstable mutant which changes at high frequency to the expressed dominant dwarfing allele during gametogenesis, or (ii) a dominant allele with penetrance determined by an unlinked modifying locus, are shown to be compatible with the experimental data. Both models indicate that penetrance of the dwarfing gene may possibly be higher in matings involving carrier daughters of the two Angus bulls.
TRAC, a collaborative computer tool for tracer-test interpretation
NASA Astrophysics Data System (ADS)
Gutierrez, A.; Klinka, T.; Thiéry, D.; Buscarlet, E.; Binet, S.; Jozja, N.; Défarge, C.; Leclerc, B.; Fécamp, C.; Ahumada, Y.; Elsass, J.
2013-05-01
Artificial tracer tests are widely used by consulting engineers for demonstrating water circulation, proving the existence of leakage, or estimating groundwater velocity. However, the interpretation of such tests is often very basic, with the result that decision makers and professionals commonly face unreliable results through hasty and empirical interpretation. There is thus an increasing need for a reliable interpretation tool, compatible with the latest operating systems and available in several languages. BRGM, the French Geological Survey, has developed a project together with hydrogeologists from various other organizations to build software assembling several analytical solutions in order to comply with various field contexts. This computer program, called TRAC, is very light and simple, allowing the user to add his own analytical solution if the formula is not yet included. It aims at collaborative improvement by sharing the tool and the solutions. TRAC can be used for interpreting data recovered from a tracer test as well as for simulating the transport of a tracer in the saturated zone (for the time being). Calibration of a site operation is based on considering the hydrodynamic and hydrodispersive features of groundwater flow as well as the amount, nature and injection mode of the artificial tracer. The software is available in French, English and Spanish, and the latest version can be downloaded from the web site http://trac.brgm.fr">http://trac.brgm.fr.
Low Speed, 2-D Rotor/Stator Active Noise Control at the Source Demonstration
NASA Technical Reports Server (NTRS)
Simonich, John C.; Kousen, Ken A.; Zander, Anthony C.; Bak, Michael; Topol, David A.
1997-01-01
Wake/blade-row interaction noise produced by the Annular Cascade Facility at Purdue University has been modeled using the LINFLO analysis. Actuator displacements needed for complete cancellation of the propagating acoustic response modes have been determined, along with the associated actuator power requirements. As an alternative, weighted least squares minimization of the total far-field sound power using individual actuators has also been examined. Attempts were made to translate the two-dimensional aerodynamic results into three-dimensional actuator requirements. The results lie near the limit of present actuator technology. In order to investigate the concept of noise control at the source for active rotor/stator noise control at the source, various techniques for embedding miniature actuators into vanes were examined. Numerous miniature speaker arrangements were tested and analyzed to determine their suitability as actuators for a demonstration test in the Annular Cascade Facility at Purdue. The best candidates demonstrated marginal performance. An alternative concept to using vane mounted speakers as control actuators was developed and tested. The concept uses compression drivers which are mounted externally to the stator vanes. Each compression driver is connected via a tube to an air cavity in the stator vane, from which the driver signal radiates into the working section of the experimental rig. The actual locations and dimensions of the actuators were used as input parameters for a LINFLO computational analysis of the actuator displacements required for complete cancellation of tones in the Purdue experimental rig. The actuators were designed and an arrangement determined which is compatible with the Purdue experimental rig and instrumentation. Experimental tests indicate that the actuators are capable of producing equivalent displacements greater than the requirements predicted by the LINFLO analysis. The acoustic output of the actuators was also found to be unaffected by the presence of air flow representative of the Purdue experimental rig. A test of the active noise control at the source concept for rotor/stator active noise control was demonstrated. This 2-D test demonstrated conclusively the simultaneous reduction of two acoustic modes. Reductions of over 10 dB were obtained over a wide operating range.
NASA Astrophysics Data System (ADS)
Clark, T. L.; McCollum, M. B.; Trout, D. H.; Javor, K.
1995-06-01
The purpose of the MEDIC Handbook is to provide practical and helpful information in the design of electrical equipment for electromagnetic compatibility (EMS). Included is the definition of electromagnetic interference (EMI) terms and units as well as an explanation of the basic EMI interactions. An overview of typical NASA EMI test requirements and associated test setups is given. General design techniques to minimize the risk of EMI and EMI suppression techniques at the board and equipment interface levels are presented. The Handbook contains specific EMI test compliance design techniques and retrofit fixes for noncompliant equipment. Also presented are special tests that are useful in the design process or in instances of specification noncompliance.
NASA Technical Reports Server (NTRS)
Clark, T. L.; Mccollum, M. B.; Trout, D. H.; Javor, K.
1995-01-01
The purpose of the MEDIC Handbook is to provide practical and helpful information in the design of electrical equipment for electromagnetic compatibility (EMS). Included is the definition of electromagnetic interference (EMI) terms and units as well as an explanation of the basic EMI interactions. An overview of typical NASA EMI test requirements and associated test setups is given. General design techniques to minimize the risk of EMI and EMI suppression techniques at the board and equipment interface levels are presented. The Handbook contains specific EMI test compliance design techniques and retrofit fixes for noncompliant equipment. Also presented are special tests that are useful in the design process or in instances of specification noncompliance.
A STUDY OF SMALL GROUP DYNAMICS AND PRODUCTIVITY IN THE BSCS LABORATORY BLOCK PROGRAM.
ERIC Educational Resources Information Center
HURD, PAUL DEHART; ROWE, MARY BUDD
THE RELATIONSHIP BETWEEN SMALL GROUP COMPATIBILITY AND ACHIEVEMENT IN THE BIOLOGICAL SCIENCE CURRICULUM STUDY LABORATORY BLOCK PROGRAM WAS TESTED. STUDENTS IN 14 CLASSES FROM FOUR HIGH SCHOOLS WERE ASSIGNED TO FOUR-MEMBER LABORATORY GROUPS CLASSIFIED AS COMPATIBLE OR INCOMPATIBLE. GROUP CLASSIFICATION WAS VALIDATED BY OBSERVERS WHO WERE NOT AWARE…
Integrated Data Collection Analysis (IDCA) Program - Mixing Procedures and Materials Compatibility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Olinger, Becky D.; Sandstrom, Mary M.; Warner, Kirstin F.
Three mixing procedures have been standardized for the IDCA proficiency test—solid-solid, solid-liquid, and liquid-liquid. Due to the variety of precursors used in formulating the materials for the test, these three mixing methods have been designed to address all combinations of materials. Hand mixing is recommended for quantities less than 10 grams and Jar Mill mixing is recommended for quantities over 10 grams. Consideration must also be given to the type of container used for the mixing due to the wide range of chemical reactivity of the precursors and mixtures. Eight web site sources from container and chemical manufacturers have beenmore » consulted. Compatible materials have been compiled as a resource for selecting containers made of materials stable to the mixtures. In addition, container materials used in practice by the participating laboratories are discussed. Consulting chemical compatibility tables is highly recommended for each operation by each individual engaged in testing the materials in this proficiency test.« less
Inducing PLA/starch compatibility through butyl-etherification of waxy and high amylose starch.
Wokadala, Obiro Cuthbert; Emmambux, Naushad Mohammad; Ray, Suprakas Sinha
2014-11-04
In this study, waxy and high amylose starches were modified through butyl-etherification to facilitate compatibility with polylactide (PLA). Fourier transform infrared spectroscopy, proton nuclear magnetic resonance spectroscopy and wettability tests showed that hydrophobic butyl-etherified waxy and high amylose starches were obtained with degree of substitution values of 2.0 and 2.1, respectively. Differential scanning calorimetry, tensile testing, and scanning electron microscopy (SEM) demonstrated improved PLA/starch compatibility for both waxy and high amylose starch after butyl-etherification. The PLA/butyl-etherified waxy and high amylose starch composite films had higher tensile strength and elongation at break compared to PLA/non-butyl-etherified composite films. The morphological study using SEM showed that PLA/butyl-etherified waxy starch composites had a more homogenous microstructure compared to PLA/butyl-etherified high amylose starch composites. Thermogravimetric analysis showed that PLA/starch composite thermal stability decreased with starch butyl-etherification for both waxy and high amylose starches. This study mainly demonstrates that PLA/starch compatibility can be improved through starch butyl-etherification. Copyright © 2014 Elsevier Ltd. All rights reserved.
Enhancing creativity: Proper body posture meets proper emotion.
Hao, Ning; Xue, Hua; Yuan, Huan; Wang, Qing; Runco, Mark A
2017-02-01
This study tested whether compatibility or incompatibility between body posture and emotion was beneficial for creativity. In Study 1, participants were asked to solve the Alternative Uses Task (AUT) problems when performing open or closed body posture in positive or negative emotional state respectively. The results showed that originality of AUT performance was higher in the compatible conditions (i.e., open-positive and closed-negative) than in the incompatible conditions (i.e., closed-positive and open-negative). In Study 2, the compatibility effect was replicated in both the AUT and the Realistic Presented Problem test (i.e., RPP). Moreover, it was revealed that participants exhibited the highest associative flexibility in the open-positive condition, and the highest persistence in the closed-negative condition. These findings indicate that compatibility between body posture and emotion is beneficial for creativity. This may be because when the implicit emotions elicited by body posture match explicit emotions, the effects of emotions on creativity are enhanced, therefore promoting creativity through the flexibility or the persistence pathway respectively. Copyright © 2016 Elsevier B.V. All rights reserved.
Expert systems for fault diagnosis in nuclear reactor control
NASA Astrophysics Data System (ADS)
Jalel, N. A.; Nicholson, H.
1990-11-01
An expert system for accident analysis and fault diagnosis for the Loss Of Fluid Test (LOFT) reactor, a small scale pressurized water reactor, was developed for a personal computer. The knowledge of the system is presented using a production rule approach with a backward chaining inference engine. The data base of the system includes simulated dependent state variables of the LOFT reactor model. Another system is designed to assist the operator in choosing the appropriate cooling mode and to diagnose the fault in the selected cooling system. The response tree, which is used to provide the link between a list of very specific accident sequences and a set of generic emergency procedures which help the operator in monitoring system status, and to differentiate between different accident sequences and select the correct procedures, is used to build the system knowledge base. Both systems are written in TURBO PROLOG language and can be run on an IBM PC compatible with 640k RAM, 40 Mbyte hard disk and color graphics.
Development of Implantable Wireless Sensor Nodes for Animal Husbandry and MedTech Innovation.
Lu, Jian; Zhang, Lan; Zhang, Dapeng; Matsumoto, Sohei; Hiroshima, Hiroshi; Maeda, Ryutaro; Sato, Mizuho; Toyoda, Atsushi; Gotoh, Takafumi; Ohkohchi, Nobuhiro
2018-03-26
In this paper, we report the development, evaluation, and application of ultra-small low-power wireless sensor nodes for advancing animal husbandry, as well as for innovation of medical technologies. A radio frequency identification (RFID) chip with hybrid interface and neglectable power consumption was introduced to enable switching of ON/OFF and measurement mode after implantation. A wireless power transmission system with a maximum efficiency of 70% and an access distance of up to 5 cm was developed to allow the sensor node to survive for a duration of several weeks from a few minutes' remote charge. The results of field tests using laboratory mice and a cow indicated the high accuracy of the collected biological data and bio-compatibility of the package. As a result of extensive application of the above technologies, a fully solid wireless pH sensor and a surgical navigation system using artificial magnetic field and a 3D MEMS magnetic sensor are introduced in this paper, and the preliminary experimental results are presented and discussed.
Analyzing the generality of conflict adaptation effects.
Funes, Maria Jesús; Lupiáñez, Juan; Humphreys, Glyn
2010-02-01
Conflict adaptation effects refer to the reduction of interference when the incongruent stimulus occurs immediately after an incongruent trial, compared with when it occurs after a congruent trial. The present study analyzes the key conditions that lead to adaptation effects that are specific to the type of conflict involved versus those that are conflict general. In the first 2 experiments, we combined 2 types of conflict for which compatibility arises from clearly different sources in terms of dimensional overlap while keeping the task context constant across conflict types. We found a clear pattern of specificity on conflict adaptation across conflict types. In subsequent experiments, we tested whether this pattern could be accounted in terms of feature integration processes contributing differently to repetition versus alternation of conflict types. The results clearly indicated that feature integration was not key to generating conflict type specificity on conflict adaptation. The data are consistent with there being separate modes of control for different types of cognitive conflict.
Validation of a dual-cycle ergometer for exercise during 100 percent oxygen prebreathing
NASA Technical Reports Server (NTRS)
Wiegman, Janet F.; Ohlhausen, John H.; Webb, James T.; Pilmanis, Andrew A.
1992-01-01
A study has been designed to determine if exercise, while prebreathing 100 percent oxygen prior to decompression, can reduce the current resting-prebreathe time requirements for extravehicular activity and high altitude reconnaissance flight. For that study, a suitable exercise mode was required. Design considerations included space limitations, cost, pressure suit compatibility, ease and maintenance of calibration, accuracy of work output, and assurance that no significant mechanical advantage or disadvantage would be introduced into the system. In addition, the exercise device must enhance denitrogenation by incorporation of both upper and lower body musculature at high levels of oxygen consumption. The purpose of this paper is to describe the specially constructed, dual-cycle ergometer developed for simultaneous arm and leg exercise during prebreathing, and to compare maximal oxygen uptake obtained on the device to that obtained during leg-only cycle ergometry and treadmill testing. Results demonstrate the suitability of the dual-cycle ergometer as an appropriate tool for exercise research during 100 percent oxygen prebreathing.
NASA Astrophysics Data System (ADS)
Paimushin, V. N.; Shishkin, V. M.
2016-01-01
A rod-shape finite element with twelve degrees of freedom is proposed for modeling the elastic and damping properties of rotor blades with regard to their geometric stiffness caused by rotation of the rotor. A model of coupling of the torsion bar with blades is developed based on the hypothesis of linear deplanation of the connecting section of the torsion bar and a special transition element to ensure the compatibility of displacements of the torsion bar and blades upon their vibrations in the flapping and rotation planes. Numerical experiments were carried out to test and assess the validity of the model developed. Suggestions are made for ensuring unconditional stability of the iteration method in a subspace in determining the specified number of modes and frequencies of free vibrations of the torsion bar-blade structure.
Aeroservoelastic Modeling of Body Freedom Flutter for Control System Design
NASA Technical Reports Server (NTRS)
Ouellette, Jeffrey
2017-01-01
One of the most severe forms of coupling between aeroelasticity and flight dynamics is an instability called freedom flutter. The existing tools often assume relatively weak coupling, and are therefore unable to accurately model body freedom flutter. Because the existing tools were developed from traditional flutter analysis models, inconsistencies in the final models are not compatible with control system design tools. To resolve these issues, a number of small, but significant changes have been made to the existing approaches. A frequency domain transformation is used with the unsteady aerodynamics to ensure a more physically consistent stability axis rational function approximation of the unsteady aerodynamic model. The aerodynamic model is augmented with additional terms to account for limitations of the baseline unsteady aerodynamic model and to account for the gravity forces. An assumed modes method is used for the structural model to ensure a consistent definition of the aircraft states across the flight envelope. The X-56A stiff wing flight-test data were used to validate the current modeling approach. The flight-test data does not show body-freedom flutter, but does show coupling between the flight dynamics and the aeroelastic dynamics and the effects of the fuel weight.
Development of multichannel MEG system at IGCAR
NASA Astrophysics Data System (ADS)
Mariyappa, N.; Parasakthi, C.; Gireesan, K.; Sengottuvel, S.; Patel, Rajesh; Janawadkar, M. P.; Radhakrishnan, T. S.; Sundar, C. S.
2013-02-01
We describe some of the challenging aspects in the indigenous development of the whole head multichannel magnetoencephalography (MEG) system at IGCAR, Kalpakkam. These are: i) fabrication and testing of a helmet shaped sensor array holder of a polymeric material experimentally tested to be compatible with liquid helium temperatures, ii) the design and fabrication of the PCB adapter modules, keeping in mind the inter-track cross talk considerations between the electrical leads used to provide connections from SQUID at liquid helium temperature (4.2K) to the electronics at room temperature (300K) and iii) use of high resistance manganin wires for the 86 channels (86×8 leads) essential to reduce the total heat leak which, however, inevitably causes an attenuation of the SQUID output signal due to voltage drop in the leads. We have presently populated 22 of the 86 channels, which include 6 reference channels to reject the common mode noise. The whole head MEG system to cover all the lobes of the brain will be progressively assembled when other three PCB adapter modules, presently under fabrication, become available. The MEG system will be used for a variety of basic and clinical studies including localization of epileptic foci during pre-surgical mapping in collaboration with neurologists.
Frei, Reto; Breitbach, Anthony S; Blackwell, Helen E
2012-05-01
We report the highly efficient syntheses of a series of focused libraries in the small molecule macroarray format using Suzuki-Miyaura and copper-catalyzed azide-alkyne cycloaddition (or "click") reactions. The libraries were based on stilbene and triazole scaffolds, which are known to have a broad range of biological activities, including quorum-sensing (QS) modulation in bacteria. The library products were generated in parallel on the macroarray in extremely short reaction times (~10-20 min) and isolated in excellent purities. Biological testing of one macroarray library post-cleavage (ex situ) revealed several potent agonists of the QS receptor, LuxR, in Vibrio fischeri. These synthetic agonists, in contrast to others that we have reported, were only active in the presence of the native QS signal in V. fischeri, which is suggestive of a different mode of activity. Notably, the results presented herein showcase the ready compatibility of the macroarray platform with chemical reactions that are commonly utilized in small molecule probe and drug discovery today. As such, this work serves to expand the utility of the small molecule macroarray as a rapid and operationally straightforward approach toward the synthesis and screening of bioactive agents.
Design of the central region for axial injection in the VINCY cyclotron
NASA Astrophysics Data System (ADS)
Milinković, Ljiljana; Toprek, Dragan
1996-02-01
This paper describes the design of the central region for h = 1, h = 2 and h = 4 modes of acceleration in the VINCY cyclotron. The result which is worth reported in that the central region is unique and compatible with the three above mentioned harmonic modes of operation. Only one spiral type inflector will be used. The central region is designed to operate with two external ion sources: (a) an ECR ion source with the maximum extraction voltage of 25 kV for heavy ions, and (b) a multicusp ion source with the maximum extraction voltage of 30 kV for H - and D - ions. Heavy ions will be accelerated by the second and fourth harmonics, D - ions by the second harmonic and H - ions by the first harmonic of the RF field. The central region is equipped with an axial injection system. The electric field distribution in the inflector and in the four acceleration gaps has been numerically calculated from an electric potential map produced by the program RELAX3D. The geometry of the central region has been tested with the computations of orbits carried out by means of the computer code CYCLONE. The optical properties of the spiral inflector and the central region were studied by using the programs CASINO and CYCLONE respectively. We have also made an effort to minimize the inflector fringe field using the RELAX3D program.
Pressurized Pepsin Digestion in Proteomics
López-Ferrer, Daniel; Petritis, Konstantinos; Robinson, Errol W.; Hixson, Kim K.; Tian, Zhixin; Lee, Jung Hwa; Lee, Sang-Won; Tolić, Nikola; Weitz, Karl K.; Belov, Mikhail E.; Smith, Richard D.; Paša-Tolić, Ljiljana
2011-01-01
Integrated top-down bottom-up proteomics combined with on-line digestion has great potential to improve the characterization of protein isoforms in biological systems and is amendable to high throughput proteomics experiments. Bottom-up proteomics ultimately provides the peptide sequences derived from the tandem MS analyses of peptides after the proteome has been digested. Top-down proteomics conversely entails the MS analyses of intact proteins for more effective characterization of genetic variations and/or post-translational modifications. Herein, we describe recent efforts toward efficient integration of bottom-up and top-down LC-MS-based proteomics strategies. Since most proteomics separations utilize acidic conditions, we exploited the compatibility of pepsin (where the optimal digestion conditions are at low pH) for integration into bottom-up and top-down proteomics work flows. Pressure-enhanced pepsin digestions were successfully performed and characterized with several standard proteins in either an off-line mode using a Barocycler or an on-line mode using a modified high pressure LC system referred to as a fast on-line digestion system (FOLDS). FOLDS was tested using pepsin and a whole microbial proteome, and the results were compared against traditional trypsin digestions on the same platform. Additionally, FOLDS was integrated with a RePlay configuration to demonstrate an ultrarapid integrated bottom-up top-down proteomics strategy using a standard mixture of proteins and a monkey pox virus proteome. PMID:20627868
Design on compatible stealth photonic crystal of nearmiddle infrared and 1.06 μm laser
NASA Astrophysics Data System (ADS)
Zhang, Ji-kui; Wang, Jia-Chun; Wang, Qi-Chao
2016-01-01
In the near and middle infrared atmospheric window, infrared stealth material require a low absorptivity (which means a low emissivity according to Kirchhoff's law of black body), at the same time, it also requires high absorptivity so as to decrease the reflectance at military laser wavelength of 1.06μm. Under this circumstances, compatible stealth of infrared and laser is an urgent demand, but the demand is ambivalent for conventional materials. Photonic crystal (PC), as a new type of artificial periodic structure function material, can realize broadband thermal infrared stealth based on its high-reflection photon forbidden band(also called photonic band gap). The high-reflection photon forbidden band of PC can be adjusted to near and middle infrared wave band through some rational methods. When a defect was added into the periodic structure of PC, a "hole-digging" reflection spectrum, which is high absorption at military laser wavelength of 1.06μm, can be achieved, so compatible stealth of near and middle infrared and military laser wavelength of 1.06μm can be achieved too. In this paper, we selected near and middle infrared-transparent materials, Te and MgF2 , as high refractive index and low refractive index material respectively, and designed a one-dimensional one-defect-mode PC whose photon forbidden band was broadened to 1-5μm by constructing two photonic crystals into one. The optical property of the PC was calculated by Transfer matrix method(TMM) of thin-film optical theory, and the results shows that the as-designed PC has a high spectral reflectance in the near and middle infrared band, among which the reflectivity in 1.68μm 5.26μm band reached more than 90%, and the 2.48 5.07μm band even reached 99.99%. The result also shows that between the band gap of 1-5μm, there are one defect mode locating in the wavelength of 1.06μm, whose reflectance is below 0.70%, which means its spectral absorptivity is greater than 99.30%. All the above we have discussed proved that this "hole-digging spectrum" PC can realize the compatible stealth of near and middle infrared and 1.06μm military laser.
NASA Astrophysics Data System (ADS)
Karzig, Torsten; Knapp, Christina; Lutchyn, Roman M.; Bonderson, Parsa; Hastings, Matthew B.; Nayak, Chetan; Alicea, Jason; Flensberg, Karsten; Plugge, Stephan; Oreg, Yuval; Marcus, Charles M.; Freedman, Michael H.
2017-06-01
We present designs for scalable quantum computers composed of qubits encoded in aggregates of four or more Majorana zero modes, realized at the ends of topological superconducting wire segments that are assembled into superconducting islands with significant charging energy. Quantum information can be manipulated according to a measurement-only protocol, which is facilitated by tunable couplings between Majorana zero modes and nearby semiconductor quantum dots. Our proposed architecture designs have the following principal virtues: (1) the magnetic field can be aligned in the direction of all of the topological superconducting wires since they are all parallel; (2) topological T junctions are not used, obviating possible difficulties in their fabrication and utilization; (3) quasiparticle poisoning is abated by the charging energy; (4) Clifford operations are executed by a relatively standard measurement: detection of corrections to quantum dot energy, charge, or differential capacitance induced by quantum fluctuations; (5) it is compatible with strategies for producing good approximate magic states.
Electrostatic repulsive out-of-plane actuator using conductive substrate.
Wang, Weimin; Wang, Qiang; Ren, Hao; Ma, Wenying; Qiu, Chuankai; Chen, Zexiang; Fan, Bin
2016-10-07
A pseudo-three-layer electrostatic repulsive out-of-plane actuator is proposed. It combines the advantages of two-layer and three-layer repulsive actuators, i.e., fabrication requirements and fill factor. A theoretical model for the proposed actuator is developed and solved through the numerical calculation of Schwarz-Christoffel mapping. Theoretical and simulated results show that the pseudo-three-layer actuator offers higher performance than the two-layer and three-layer actuators with regard to the two most important characteristics of actuators, namely, driving force and theoretical stroke. Given that the pseudo-three-layer actuator structure is compatible with both the parallel-plate actuators and these two types of repulsive actuators, a 19-element two-layer repulsive actuated deformable mirror is operated in pseudo-three-layer electrical connection mode. Theoretical and experimental results demonstrate that the pseudo-three-layer mode produces a larger displacement of 0-4.5 μm for a dc driving voltage of 0-100 V, when compared with that in two-layer mode.
Electrostatic repulsive out-of-plane actuator using conductive substrate
Wang, Weimin; Wang, Qiang; Ren, Hao; Ma, Wenying; Qiu, Chuankai; Chen, Zexiang; Fan, Bin
2016-01-01
A pseudo-three-layer electrostatic repulsive out-of-plane actuator is proposed. It combines the advantages of two-layer and three-layer repulsive actuators, i.e., fabrication requirements and fill factor. A theoretical model for the proposed actuator is developed and solved through the numerical calculation of Schwarz-Christoffel mapping. Theoretical and simulated results show that the pseudo-three-layer actuator offers higher performance than the two-layer and three-layer actuators with regard to the two most important characteristics of actuators, namely, driving force and theoretical stroke. Given that the pseudo-three-layer actuator structure is compatible with both the parallel-plate actuators and these two types of repulsive actuators, a 19-element two-layer repulsive actuated deformable mirror is operated in pseudo-three-layer electrical connection mode. Theoretical and experimental results demonstrate that the pseudo-three-layer mode produces a larger displacement of 0–4.5 μm for a dc driving voltage of 0–100 V, when compared with that in two-layer mode. PMID:27713542
Multipolar second-harmonic generation by Mie-resonant dielectric nanoparticles
NASA Astrophysics Data System (ADS)
Smirnova, Daria; Smirnov, Alexander I.; Kivshar, Yuri S.
2018-01-01
By combining analytical and numerical approaches, we study resonantly enhanced second-harmonic generation by individual high-index dielectric nanoparticles made of centrosymmetric materials. Considering both bulk and surface nonlinearities, we describe second-harmonic nonlinear scattering from a silicon nanoparticle optically excited in the vicinity of the magnetic and electric dipolar resonances. We discuss the contributions of different nonlinear sources and the effect of the low-order optical Mie modes on the characteristics of the generated far field. We demonstrate that the multipolar expansion of the radiated field is dominated by dipolar and quadrupolar modes (two axially symmetric electric quadrupoles, an electric dipole, and a magnetic quadrupole) and the interference of these modes can ensure directivity of the nonlinear scattering. The developed multipolar analysis can be instructive for interpreting the far-field measurements of the nonlinear scattering and it provides prospective insights into a design of complementary metal-oxide-semiconductor compatible nonlinear nanoantennas fully integrated with silicon-based photonic circuits, as well as methods of nonlinear diagnostics.
2006-11-08
Communications, Navigation, and Network Reconfigurable Test-bed (CoNNeCT) Flight Hardware Compatibility Test Sets - Glenn Research Center and Networks Integration Management Office (NIMO) Testing for the Tracking and Data Relay Satellite System (TDRSS) - Goddard Space Flight Center Testing
2006-11-16
Communications, Navigation, and Network Reconfigurable Test-bed (CoNNeCT) Flight Hardware Compatibility Test Sets - Glenn Research Center and Networks Integration Management Office (NIMO) Testing for the Tracking and Data Relay Satellite System (TDRSS) - Goddard Space Flight Center Testing
Ziessler, Michael; Nattkemper, Dieter; Vogt, Stefan
2012-01-01
Evidence for the anticipation of environmental effects as an integral part of response planning comes mainly from experiments in which the effects were physically presented. Thus, in these studies it cannot be excluded that effect codes were activated during response preparation only because the effects were displayed as external stimuli before response execution. In order to provide more clear-cut evidence for the anticipation of response effects in action planning, we performed a series of three experiments using a new paradigm, where displaying effect codes before the response was avoided. Participants first learned arbitrary effects of key-pressing responses. In the following test phase they were instructed to execute a response only if a Go stimulus was presented after a variable stimulus onset asynchrony (SOA). The Go stimulus was either compatible or incompatible with the effect, but independent of the response. In Experiment 1 we tested the paradigm with two responses and two effects. We found a significant compatibility effect: If the Go stimulus was compatible with the response effect, responses were initiated faster than in incompatible trials. In Experiment 2 response effects were only present in the acquisition phase, but not in the test phase. The compatibility effect disappeared, indicating that the results of Experiment 1 were indeed related to the anticipation of the forthcoming response effects. In Experiment 3 we extended this paradigm by using a larger number of stimuli and response alternatives. Again we found a robust compatibility effect, which can only be explained if the effect representations are active before response execution. The compatibility effects in Experiments 1 and 3 did not depend on the SOA. The fact that the Go stimulus affected response preparation at any time indicates that the role of effect anticipation is not limited to response selection. PMID:23293623
NASA Technical Reports Server (NTRS)
Burns, H. D.; Mitchell, M. A.; McMillian, J. H.; Farner, B. R.; Harper, S. A.; Peralta, S. F.; Lowrey, N. M.; Ross, H. R.; Juarez, A.
2015-01-01
Since the 1990's, NASA's rocket propulsion test facilities at Marshall Space Flight Center (MSFC) and Stennis Space Center (SSC) have used hydrochlorofluorocarbon-225 (HCFC-225), a Class II ozone-depleting substance, to safety clean and verify the cleanliness of large scale propulsion oxygen systems and associated test facilities. In 2012 through 2014, test laboratories at MSFC, SSC, and Johnson Space Center-White Sands Test Facility collaborated to seek out, test, and qualify an environmentally preferred replacement for HCFC-225. Candidate solvents were selected, a test plan was developed, and the products were tested for materials compatibility, oxygen compatibility, cleaning effectiveness, and suitability for use in cleanliness verification and field cleaning operations. Honewell Soltice (TradeMark) Performance Fluid (trans-1-chloro-3,3, 3-trifluoropropene) was selected to replace HCFC-225 at NASA's MSFC and SSC rocket propulsion test facilities.
Multimode and single-mode fibers for data center and high-performance computing applications
NASA Astrophysics Data System (ADS)
Bickham, Scott R.
2016-03-01
Data center (DC) and high performance computing (HPC) applications have traditionally used a combination of copper, multimode fiber and single-mode fiber interconnects with relative percentages that depend on factors such as the line rate, reach and connectivity costs. The balance between these transmission media has increasingly shifted towards optical fiber due to the reach constraints of copper at data rates of 10 Gb/s and higher. The percentage of single-mode fiber deployed in the DC has also grown slightly since 2014, coinciding with the emergence of mega DCs with extended distance needs beyond 100 m. This trend will likely continue in the next few years as DCs expand their capacity from 100G to 400G, increase the physical size of their facilities and begin to utilize silicon-photonics transceiver technology. However there is a still a need for the low-cost and high-density connectivity, and this is sustaining the deployment of multimode fiber for links <= 100 m. In this paper, we discuss options for single-mode and multimode fibers in DCs and HPCs and introduce a reduced diameter multimode fiber concept which provides intra-and inter-rack connectivity as well as compatibility with silicon-photonic transceivers operating at 1310 nm. We also discuss the trade-offs between single-mode fiber attributes such as bend-insensitivity, attenuation and mode field diameter and their roles in capacity and connectivity in data centers.
NASA Technical Reports Server (NTRS)
Brinca, A. L.; Tsurutani, B. T.
1987-01-01
The characteristics of electromagnetic waves excited by cometary newborn ions with large perpendicular energies are examined using a model of solar wind permeated by dilute drifting ring distributions of electrons and oxygen ions with finite thermal spreads. The model has parameters compatible with the ICE observations at the Giacobini-Zinner comet. It is shown that cometary newborn ions with large perpendicular energies can excite a wave mode with rest frame frequencies in the order of the heavy ion cyclotron frequency, Omega(i), and unusual propagation characteristics at small obliquity angles. For parallel propagation, the mode is left-hand circularly polarized, might be unstable in a frequency range containing Omega(i), and moves in the direction of the newborn ion drift along the static magnetic field.
High performance waveguide-coupled Ge-on-Si linear mode avalanche photodiodes.
Martinez, Nicholas J D; Derose, Christopher T; Brock, Reinhard W; Starbuck, Andrew L; Pomerene, Andrew T; Lentine, Anthony L; Trotter, Douglas C; Davids, Paul S
2016-08-22
We present experimental results for a selective epitaxially grown Ge-on-Si separate absorption and charge multiplication (SACM) integrated waveguide coupled avalanche photodiode (APD) compatible with our silicon photonics platform. Epitaxially grown Ge-on-Si waveguide-coupled linear mode avalanche photodiodes with varying lateral multiplication regions and different charge implant dimensions are fabricated and their illuminated device characteristics and high-speed performance is measured. We report a record gain-bandwidth product of 432 GHz for our highest performing waveguide-coupled avalanche photodiode operating at 1510nm. Bit error rate measurements show operation with BER< 10-12, in the range from -18.3 dBm to -12 dBm received optical power into a 50 Ω load and open eye diagrams with 13 Gbps pseudo-random data at 1550 nm.
Polymer waveguides for electro-optical integration in data centers and high-performance computers.
Dangel, Roger; Hofrichter, Jens; Horst, Folkert; Jubin, Daniel; La Porta, Antonio; Meier, Norbert; Soganci, Ibrahim Murat; Weiss, Jonas; Offrein, Bert Jan
2015-02-23
To satisfy the intra- and inter-system bandwidth requirements of future data centers and high-performance computers, low-cost low-power high-throughput optical interconnects will become a key enabling technology. To tightly integrate optics with the computing hardware, particularly in the context of CMOS-compatible silicon photonics, optical printed circuit boards using polymer waveguides are considered as a formidable platform. IBM Research has already demonstrated the essential silicon photonics and interconnection building blocks. A remaining challenge is electro-optical packaging, i.e., the connection of the silicon photonics chips with the system. In this paper, we present a new single-mode polymer waveguide technology and a scalable method for building the optical interface between silicon photonics chips and single-mode polymer waveguides.
Dynamic analysis of rotor flex-structure based on nonlinear anisotropic shell models
NASA Astrophysics Data System (ADS)
Bauchau, Olivier A.; Chiang, Wuying
1991-05-01
In this paper an anisotropic shallow shell model is developed that accommodates transverse shearing deformations and arbitrarily large displacements and rotations, but strains are assumed to remain small. Two kinematic models are developed, the first using two DOF to locate the direction of the normal to the shell's midplane, the second using three. The latter model allows for an automatic compatibility of the shell model with beam models. The shell model is validated by comparing its predictions with several benchmark problems. In actual helicopter rotor blade problems, the shell model of the flex structure is shown to give very different results shown compared to beam models. The lead-lag and torsion modes in particular are strongly affected, whereas flapping modes seem to be less affected.
NASA Astrophysics Data System (ADS)
Zhu, Jun; Chen, Lijun; Ma, Lantao; Li, Dejian; Jiang, Wei; Pan, Lihong; Shen, Huiting; Jia, Hongmin; Hsiang, Chingyun; Cheng, Guojie; Ling, Li; Chen, Shijie; Wang, Jun; Liao, Wenkui; Zhang, Gary
2014-04-01
Defect review is a time consuming job. Human error makes result inconsistent. The defects located on don't care area would not hurt the yield and no need to review them such as defects on dark area. However, critical area defects can impact yield dramatically and need more attention to review them such as defects on clear area. With decrease in integrated circuit dimensions, mask defects are always thousands detected during inspection even more. Traditional manual or simple classification approaches are unable to meet efficient and accuracy requirement. This paper focuses on automatic defect management and classification solution using image output of Lasertec inspection equipment and Anchor pattern centric image process technology. The number of mask defect found during an inspection is always in the range of thousands or even more. This system can handle large number defects with quick and accurate defect classification result. Our experiment includes Die to Die and Single Die modes. The classification accuracy can reach 87.4% and 93.3%. No critical or printable defects are missing in our test cases. The missing classification defects are 0.25% and 0.24% in Die to Die mode and Single Die mode. This kind of missing rate is encouraging and acceptable to apply on production line. The result can be output and reloaded back to inspection machine to have further review. This step helps users to validate some unsure defects with clear and magnification images when captured images can't provide enough information to make judgment. This system effectively reduces expensive inline defect review time. As a fully inline automated defect management solution, the system could be compatible with current inspection approach and integrated with optical simulation even scoring function and guide wafer level defect inspection.
Maruo, Tomoyuki; Saitoh, Youichi; Hosomi, Koichi; Kishima, Haruhiko; Shimokawa, Toshio; Hirata, Masayuki; Goto, Tetsu; Morris, Shayne; Harada, Yu; Yanagisawa, Takufumi; Aly, Mohamed M; Yoshimine, Toshiki
2011-04-01
Patients with Parkinson's disease (PD) reportedly show deficits in sensory processing in addition to motor symptoms. However, little is known about the effects of bilateral deep brain stimulation of the subthalamic nucleus (STN-DBS) on temperature sensation as measured by quantitative sensory testing (QST). This study was designed to quantitatively evaluate the effects of STN-DBS on temperature sensation and pain in PD patients. We conducted a QST study comparing the effects of STN-DBS on cold sense thresholds (CSTs) and warm sense thresholds (WSTs) as well as on cold-induced and heat-induced pain thresholds (CPT and HPT) in 17 PD patients and 14 healthy control subjects. The CSTs and WSTs of patients were significantly smaller during the DBS-on mode when compared with the DBS-off mode (P<.001), whereas the CSTs and WSTs of patients in the DBS-off mode were significantly greater than those of healthy control subjects (P<.02). The CPTs and HPTs in PD patients were significantly larger on the more affected side than on the less affected side (P<.02). Because elevations in thermal sense and pain thresholds of QST are reportedly almost compatible with decreases in sensation, our findings confirm that temperature sensations may be disturbed in PD patients when compared with healthy persons and that STN-DBS can be used to improve temperature sensation in these patients. The mechanisms underlying our findings are not well understood, but improvement in temperature sensation appears to be a sign of modulation of disease-related brain network abnormalities. Copyright © 2010 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.
Visual land-use compatibility and scenic-resource quality
William G. Hendrix
1977-01-01
The effect that land-use relationships have upon perceived quality of the visual landscape is discussed, and a case is made for expansion of fit-misfit theory into what has been called visual land-use compatibility. An assessment methodology that was designed to test people's perceptions of land-use relationships is presented and the results are discussed.
NASA Applications for Computational Electromagnetic Analysis
NASA Technical Reports Server (NTRS)
Lewis, Catherine C.; Trout, Dawn H.; Krome, Mark E.; Perry, Thomas A.
2011-01-01
Computational Electromagnetic Software is used by NASA to analyze the compatibility of systems too large or too complex for testing. Recent advances in software packages and computer capabilities have made it possible to determine the effects of a transmitter inside a launch vehicle fairing, better analyze the environment threats, and perform on-orbit replacements with assured electromagnetic compatibility.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Rate of Permeation in Plastic Packaging and Receptacles B Appendix B to Part 173 Transportation Other... Plastic Packaging and Receptacles 1. The purpose of this procedure is to determine the chemical compatibility and permeability of liquid hazardous materials packaged in plastic packaging and receptacles...
Code of Federal Regulations, 2010 CFR
2010-10-01
... Rate of Permeation in Plastic Packaging and Receptacles B Appendix B to Part 173 Transportation Other... Plastic Packaging and Receptacles 1. The purpose of this procedure is to determine the chemical compatibility and permeability of liquid hazardous materials packaged in plastic packaging and receptacles...
Code of Federal Regulations, 2012 CFR
2012-10-01
... Rate of Permeation in Plastic Packaging and Receptacles B Appendix B to Part 173 Transportation Other... Plastic Packaging and Receptacles 1. The purpose of this procedure is to determine the chemical compatibility and permeability of liquid hazardous materials packaged in plastic packaging and receptacles...
Code of Federal Regulations, 2013 CFR
2013-10-01
... Rate of Permeation in Plastic Packaging and Receptacles B Appendix B to Part 173 Transportation Other... Plastic Packaging and Receptacles 1. The purpose of this procedure is to determine the chemical compatibility and permeability of liquid hazardous materials packaged in plastic packaging and receptacles...
Emissions data by category of engines
NASA Technical Reports Server (NTRS)
Barriage, J.; Westfield, W.; Becker, E. E.
1976-01-01
Exhaust gas pollutant emissions data under test stand conditions were obtained for the following: (1) full-rich baseline test (7-mode cycle), (2) lean-out tests for each power mode, and (3) different spark settings. The test data were also used to create a theoretical 5-mode cycle baseline. The emissions data in the framework of the theoretical 5-mode cycle were emphasized. There is no significant difference in the test results produced by data exhibited on the 7-mode cycle or 5-mode cycle. The 5-mode cycle was slightly more conservative for the carbon monoxide pollutant than the 7-mode cycle. The data were evaluated to determine which mode(s) had the greatest influence on improving general aviation piston engine emissions. Improvements that were achieved as a result of making lean-out adjustments to the fuel metering device were: (1) taxi mode only, (2) taxi and approach modes combined, and (3) leaning-out of the climb mode to best power.
1983-06-01
NOTES 19. KEY WORDS (Continue on reveree side if necesaary and Identify by block number) Neoprene Synthetic Liners TCE, XR-5, EPDM Hypalon Compatibility...CPE, Hypalon , XR-5, HDPE, Neoprene, and EPDM ) were immersed in TNT, RDX, and TCE solutions for I week. Liner and test .*. method selection and data...Mean Weight Change Values - EPDM /Neoprene Group 57 Unexposed and in Distilled Water 7 Mean Weight Change Values - PVC Group in Distilled 58 Water and in
Development of Simulated Disturbing Source for Isolation Switch
NASA Astrophysics Data System (ADS)
Cheng, Lin; Liu, Xiang; Deng, Xiaoping; Pan, Zhezhe; Zhou, Hang; Zhu, Yong
2018-01-01
In order to simulate the substation in the actual scene of the harsh electromagnetic environment, and then research on electromagnetic compatibility testing of electronic instrument transformer, On the basis of the original isolation switch as a harassment source of the electronic instrument transformer electromagnetic compatibility test system, an isolated switch simulation source system was developed, to promote the standardization of the original test. In this paper, the circuit breaker is used to control the opening and closing of the gap arc to simulate the operating of isolating switch, and the isolation switch simulation harassment source system is designed accordingly. Comparison with the actual test results of the isolating switch, it is proved that the system can meet the test requirements, and the simulation harassment source system has good stability and high reliability.
Mixed-Mode Bending Method for Delamination Testing
NASA Technical Reports Server (NTRS)
Reeder, James R.; Crews, John R., Jr.
1990-01-01
A mixed mode delamination test procedure was developed combining double cantilever beam (DCB) mode I loading and end-notch fixture (ENF) mode II loading on a split unidirectional laminate. By loading with a lever, a single applied load simultaneously produces mode I and mode II bending loads on the specimen. This mixed-mode bending (MMB) test was analyzed using both finite-element procedures and beam theory to calculate the mode I and mode II components of strain-energy release rate G(sub I) and G(sub II), respectively. A wide range of G(sub I)/G(sub II) ratios can be produced by varying the load position on the lever. As the delamination extended, the G(sub I)/G(sub II) ratios varied by less than 5%. Beam theory equations agreed closely with the finite-element results and provide a basis for selection of G(sub I)/G(sub II) test ratios and a basis for computing the mode I and mode II components of measured delamination toughness. The MMB test was demonstrated using AS4/PEEK (APC2) unidirectional laminates. The MMB test introduced in this paper is rather simple and is believed to offer several advantages over most current mixed-mode test.
Continuing Issues (FY 1979) Regarding DoD Use of the Space Transportation System.
1979-12-01
estimates) to the cost of launching experimental payloads In the sortie mode is the analytical verification of compatibility ("Integrsaton") of the experiment...with the Shuttle; the Integration cost mya be reduced by the Air Force by treir proposed "class cargo" generalized integra- tion analysis that, once...camactness and light weight (for a given experimental weight) rather than on intrinsic cost , to minmize lazc costa as couted by the NASA volume and weight
Generation of High Purity Photon-Pair in a Short Highly Non-Linear Fiber
2013-01-01
Avalanche photodiode. A 10 m long HNLF fabricated by Sumitomo with a core diameter of 4 microns is fusion spliced to a single mode fiber for a...parametric down conversion (SPDC) was first observed in χ(2) nonlinear crystal [3]. However, the compatibility of a nonlinear crystal source with fiber and...PAIR IN A SHORT HIGHLY NON-LINEAR FIBER 5a. CONTRACT NUMBER 5b. GRANT NUMBER FA8750-12-1-0136 5c. PROGRAM ELEMENT NUMBER N/A 6. AUTHOR(S
Evanescent Modes and Tunnelling Instantaneously Act at a Distance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nimtz, Guenter; Stahlhofen, Alfons A.
Photonic tunnelling experiments have shown that i) the Einstein energy relation is violated, ii) the tunnelling process is non-local, iii) the signal velocity is faster than light, i.e. superluminal, iv) the tunnelling signal is not observable, since photonic tunnelling is described by virtual photons, and v) according to the experimental results the signal velocity is infinite inside the barriers, implying that tunnelling instantaneously acts at a distance. We think these properties are not compatible with the claims of many text books on Special Relativity.
Driving platform for OLED lighting investigations
NASA Astrophysics Data System (ADS)
Vogel, Uwe; Elgner, Andreas; Kreye, Daniel; Amelung, Jörg; Scholles, Michael
2006-08-01
OLED technology may be excellently suitable for lighting applications by combining high efficiency, cost effective manufacturing and the use of low cost materials. Certain issues remain to be solved so far, including OLED brightness, color, lifetime, large area uniformity and encapsulation. Another aspect, that might be capable in addressing some of the mentioned issues, is OLED lighting electrical driving. We report on the design of a driving platform for OLED lighting test panels or substrates. It is intended for being a test environment for lighting substrates as well as demonstration/presentation environment. It is based on a 128-channel passive-matrix driver/controller ASIC OC2. Its key component is an MSP430-compatible 16-bit micro-controller core including embedded Flash memory (program), EEPROM (parameter), and RAM (data memory). A significant feature of the device is an electronic approach for improving the lifetime/uniformity behavior of connected OLED. The embedded micro-controller is the key to the high versatility of OC2, since by firmware modification it can be adapted to various applications and conditions. Here its application for an OLED lighting driving platform is presented. Major features of this platform are PC-control mode (via USB interface), stand-alone mode (no external control necessary, just power supply), on-board OLED panel parameter storage, flat geometry of OLED lighting panel carrier (board), AC and DC driving regimes, adjustable reverse voltage, dedicated user SW (PC/Windows-based), sub-tile patterning and single sub-tile control, combination of multiple channels for increasing driving current. This publication contains results of the project "High Brightness OLEDs for ICT & Next Generation Lighting Applications" (OLLA), funded by the European Commission.
DTT: a divertor tokamak test facility for the study of the power exhaust issues in view of DEMO
NASA Astrophysics Data System (ADS)
Albanese, R.; WPDTT2 Team; DTT Project Proposal Contributors, the
2017-01-01
In parallel with the programme to optimize the operation with a conventional divertor based on detached conditions to be tested on the ITER device, a project has been launched to investigate alternative power exhaust solutions for DEMO, aimed at the definition and the design of a divertor tokamak test facility (DTT). The DTT project proposal refers to a set of parameters selected so as to have edge conditions as close as possible to DEMO, while remaining compatible with DEMO bulk plasma performance in terms of dimensionless parameters and given constraints. The paper illustrates the DTT project proposal, referring to a 6 MA plasma with a major radius of 2.15 m, an aspect ratio of about 3, an elongation of 1.6-1.8, and a toroidal field of 6 T. This selection will guarantee sufficient flexibility to test a wide set of divertor concepts and techniques to cope with large heat loads, including conventional tungsten divertors; liquid metal divertors; both conventional and advanced magnetic configurations (including single null, snow flake, quasi snow flake, X divertor, double null); internal coils for strike point sweeping and control of the width of the scrape-off layer in the divertor region; and radiation control. The Poloidal Field system is planned to provide a total flux swing of more than 35 Vs, compatible with a pulse length of more than 100 s. This is compatible with the mission of studying the power exhaust problem and is obtained using superconducting coils. Particular attention is dedicated to diagnostics and control issues, especially those relevant for plasma control in the divertor region, designed to be as compatible as possible with a DEMO-like environment. The construction is expected to last about seven years, and the selection of an Italian site would be compatible with a budget of 500 M€.
NASA Technical Reports Server (NTRS)
Anderson, W. E.; Boxwell, R.; Crockett, D. V.; Ross, R.; Lewis, T.; McNeal, C.; Verdarame, K.
1999-01-01
For propulsion applications that require that the propellants are storable for long periods, have a high density impulse, and are environmentally clean and non-toxic, the best choice is a combination of high-concentration hydrogen peroxide (High Test Peroxide, or HTP) and a liquid hydrocarbon (LHC) fuel. The HTP/LHC combination is suitable for low-cost launch vehicles, space taxi and space maneuvering vehicles, and kick stages. Orbital Sciences Corporation is under contract with the NASA Marshall Space Flight Center in cooperation with the Air Force Research Lab to design, develop and demonstrate a new low-cost liquid upper stage based on HTP and JP-8. The Upper Stage Flight Experiment (USFE) focuses on key technologies necessary to demonstrate the operation of an inherently simple propulsion system with an innovative, state-of-the-art structure. Two key low-cost vehicle elements will be demonstrated - a 10,000 lbf thrust engine and an integrated composite tank structure. The suborbital flight test of the USFE is scheduled for 2001. Preceding the flight tests are two major series of ground tests at NASA Stennis Space Center and a subscale tank development program to identify compatible composite materials and to verify their compatibility over long periods of time. The ground tests include a thrust chamber development test series and an integrated stage test. This paper summarizes the results from the first phase of the thrust chamber development tests and the results to date from the tank material compatibility tests. Engine and tank configurations that meet the goals of the program are described.
Orbital transfer rocket engine technology program: Soft wear ring seal technology
NASA Technical Reports Server (NTRS)
Lariviere, Brian W.
1992-01-01
Liquid oxygen (LOX) compatibility tests, including autogenous ignition, promoted ignition, LOX impact tests, and friction and wear tests on different PV products were conducted for several polymer materials as verification for the implementation of soft wear ring seals in advanced rocket engine turbopumps. Thermoplastics, polyimide based materials, and polyimide-imide base materials were compared for oxygen compatibility, specific wear coefficient, wear debris production, and heat dissipation mechanisms. A thermal model was generated that simulated the frictional heating input and calculated the surface temperature and temperature distribution within the seal. The predictions were compared against measured values. Heat loads in the model were varied to better match the test data and determine the difference between the measured and the calculated coefficients of friction.
Hamilton Standard Q-fan demonstrator dynamic pitch change test program, volume 1
NASA Technical Reports Server (NTRS)
Demers, W. J.; Nelson, D. J.; Wainauski, H. S.
1975-01-01
Tests of a full scale variable pitch fan engine to obtain data on the structural characteristics, response times, and fan/core engine compatibility during transient changes in blade angle, fan rpm, and engine power is reported. Steady state reverse thrust tests with a take off nozzle configuration were also conducted. The 1.4 meter diameter, 13 bladed controllable pitch fan was driven by a T55 L 11A engine with power and blade angle coordinated by a digital computer. The tests demonstrated an ability to change from full forward thrust to reverse thrust in less than one (1) second. Reverse thrust was effected through feather and through flat pitch; structural characteristics and engine/fan compatibility were within satisfactory limits.
Designing degradable hydrogels for orthogonal control of cell microenvironments
Kharkar, Prathamesh M.
2013-01-01
Degradable and cell-compatible hydrogels can be designed to mimic the physical and biochemical characteristics of native extracellular matrices and provide tunability of degradation rates and related properties under physiological conditions. Hence, such hydrogels are finding widespread application in many bioengineering fields, including controlled bioactive molecule delivery, cell encapsulation for controlled three-dimensional culture, and tissue engineering. Cellular processes, such as adhesion, proliferation, spreading, migration, and differentiation, can be controlled within degradable, cell-compatible hydrogels with temporal tuning of biochemical or biophysical cues, such as growth factor presentation or hydrogel stiffness. However, thoughtful selection of hydrogel base materials, formation chemistries, and degradable moieties is necessary to achieve the appropriate level of property control and desired cellular response. In this review, hydrogel design considerations and materials for hydrogel preparation, ranging from natural polymers to synthetic polymers, are overviewed. Recent advances in chemical and physical methods to crosslink hydrogels are highlighted, as well as recent developments in controlling hydrogel degradation rates and modes of degradation. Special attention is given to spatial or temporal presentation of various biochemical and biophysical cues to modulate cell response in static (i.e., non-degradable) or dynamic (i.e., degradable) microenvironments. This review provides insight into the design of new cell-compatible, degradable hydrogels to understand and modulate cellular processes for various biomedical applications. PMID:23609001
Just Out of Reach: On the Reliability of the Action-Sentence Compatibility Effect
Papesh, Megan H.
2015-01-01
The action-sentence compatibility effect (ACE; Glenberg & Kaschak, 2002), a hallmark finding in Embodied Cognition, implicates the motor system in language comprehension. In the ACE, people process sentences implying movement toward or away from themselves, responding with actions toward or away from their bodies. These processes interact, implying a linkage between linguistic and motor systems. From a theoretical perspective, the ACE has been extremely influential, being widely-cited evidence in favor of embodied cognition. The present study began as an attempt to extend the ACE in a new direction, but eventually became a series of attempts to simply replicate the effect. Across eight experiments, I tested whether the ACE extends to a novel mouse-tracking method and/or is susceptible to higher-order cognitive influences. In three experiments, attempts were made to “disembody” the ACE by presenting participants' names on the computer screen (as in Markman & Brendl, 2005). In each experiment, the ACE could not be disembodied, because the ACE did not occur. In further experiments, the ACE was not observed in reading times, regardless of response mode (mouse movements versus button-presses) or stimuli, including those from the original research. Similarly, no ACE was observed in physical movement times. Bayes Factor analyses of the current experiments, and the previous ACE literature, suggest that the evidence for the ACE is generally weak: Many studies considered as positive evidence actually support the null hypothesis, and very few published results offer strong evidence for the ACE. Implications for the embodiment hypothesis are discussed. PMID:26595844
Permeability modes in fluctuating lipid membranes with DNA-translocating pores.
Moleiro, L H; Mell, M; Bocanegra, R; López-Montero, I; Fouquet, P; Hellweg, Th; Carrascosa, J L; Monroy, F
2017-09-01
Membrane pores can significantly alter not only the permeation dynamics of biological membranes but also their elasticity. Large membrane pores able to transport macromolecular contents represent an interesting model to test theoretical predictions that assign active-like (non-equilibrium) behavior to the permeability contributions to the enhanced membrane fluctuations existing in permeable membranes [Maneville et al. Phys. Rev. Lett. 82, 4356 (1999)]. Such high-amplitude active contributions arise from the forced transport of solvent and solutes through the open pores, which becomes even dominant at large permeability. In this paper, we present a detailed experimental analysis of the active shape fluctuations that appear in highly permeable lipid vesicles with large macromolecular pores inserted in the lipid membrane, which are a consequence of transport permeability events occurred in an osmotic gradient. The experimental results are found in quantitative agreement with theory, showing a remarkable dependence with the density of membrane pores and giving account of mechanical compliances and permeability rates that are compatible with the large size of the membrane pore considered. The presence of individual permeation events has been detected in the fluctuation time-series, from which a stochastic distribution of the permeation events compatible with a shot-noise has been deduced. The non-equilibrium character of the membrane fluctuations in a permeation field, even if the membrane pores are mere passive transporters, is clearly demonstrated. Finally, a bio-nano-technology outlook of the proposed synthetic concept is given on the context of prospective uses as active membrane DNA-pores exploitable in gen-delivery applications based on lipid vesicles. Copyright © 2017 Elsevier B.V. All rights reserved.
Wu, Chang-Lin; He, Jian-An; Gu, Da-Yong; Shao, Chao-Peng; Zhu, Yi; Dang, Xin-Tang
2018-01-01
This study was aimed to establish a novel strategy based on the surface plasmon resonance (SPR) technology for platelet compatibility testing. A novel surface matrix was prepared based on poly (OEGMA-co-HEMA) via surface-initiated polymerization as a biosensor surface platform. Type O universal platelets and donor platelets were immobilized on these novel matrices via amine-coupling reaction and worked as a capturing ligand for binding the platelet antibody. Antibodies binding to platelets were monitored in real time by injecting the samples into a microfluidic channel. Clinical serum samples (n = 186) with multiple platelet transfusions were assayed for platelet antibodies using the SPR technology and monoclonal antibody-immobilized platelet antigen (MAIPA) assay. The novel biosensor surface achieved nonfouling background and high immobilization capacity and showed good repeatability and stability after regeneration. The limit of detection of the SPR biosensor for platelet antibody was estimated to be 50 ng/mL. The sensitivity and specificity were 92% and 98.7%. It could detect the platelet antibody directly in serum samples, and the results were similar to MAIPA assay. A novel strategy to facilitate the sensitive and reliable detection of platelet compatibility for developing an SPR-based biosensor was established in this study. The SPR-based biosensor combined with novel surface chemistry is a promising method for platelet compatibility testing.
Highly efficient and compatible shampoo for use after hair transplant.
Schweiger, Dorothea; Schoelermann, Andrea M; Filbry, Alexander; Hamann, Tina; Moser, Claudia; Rippke, Frank
2015-01-01
Sensitive or hyperreactive skin is a common condition defined by prickling, burning, pain, and pruritus. Although this skin problem was initially described on the face, the scalp is often affected. A sensitive scalp can react with irritation to harsh surfactants or other additives which are often present in shampoos. For this reason, we developed a new rinse-off hypertolerant shampoo specifically designed for the hypersensitive and problematic scalp. The shampoo formulation is based on an extremely mild surfactant system and contains bisabolol, an anti-irritant and anti-inflammatory ingredient of chamomile. The shampoo is free of additives such as perfumes, silicones, colorants, parabens, paraffins, and betaine. Since skin can remain in a hyperreactive state after wounding, the status after hair transplantation was chosen as a model system to test the shampoo. Scalp condition and compatibility of each volunteer were analyzed by a plastic surgeon directly after hair transplant and after stitch removal. The plastic surgeons also rated whether they would recommend the further use of the test shampoo. Additionally, volunteers completed a self-assessment questionnaire. Following hair transplantation, regular use of the shampoo resulted in a significant reduction in the extent of scabbing and erythema. This was confirmed by dermatological scalp examinations performed by the plastic surgeon as well as in volunteers' self-assessments. The plastic surgeon highly recommended the further use of the test shampoo after hair transplant to all study participants. Application of the test shampoo demonstrated excellent skin compatibility and product efficacy after hair transplant. The test shampoo significantly reduced the extent of scabs and erythema. Therefore, the shampoo is ideally suited for use after hair transplantation and for the treatment of sensitive scalp. The excellent skin compatibility is because of the mild surfactant system, the calming ingredient bisabolol, and the absence of potentially irritating ingredients.
Compatibility tests between Jarytherm DBT synthetic oil and solid materials from wastes
NASA Astrophysics Data System (ADS)
Fasquelle, Thomas; Falcoz, Quentin; Neveu, Pierre; Flamant, Gilles; Walker, Jérémie
2016-05-01
Direct thermocline thermal energy storage is the cheapest sensible thermal energy storage configuration. Indeed, a thermocline tank consists in one tank instead of two and reduces costs. Thermocline thermal energy storages are often filled with cheap solid materials which could react with the heat transfer fluid in the case of incompatibility. PROMES laboratory is building a pilot-scale parabolic trough solar loop including a direct thermocline thermal energy storage system. The working fluid will be a synthetic oil, the Jarytherm® DBT, and the thermal energy storage tank will be filled with stabilized solid materials elaborated from vitrified wastes. Compatibility tests have been conducted in order to check on one hand if the thermo-mechanical properties and life time of the energy storage medium are not affected by the contact with oil and, on the other hand, if the thermal oil performances are not degraded by the solid filler. These experiments consisted in putting in contact the oil and the solid materials in small tanks. In order to discriminate the solid materials tested in the shortest time, accelerating aging conditions at 330 °C for 500 hours were used. The measurements consisted in X-Ray Diffraction and Scanning Electron Microscopy for the solids, and thermo-physical and chemical properties measurements for the oil. Regarding the solid samples, their crystalline structure did not change during the test, but it is difficult to conclude about their elementary composition and they seem to absorb oil. While thermal properties still makes Jarytherm® DBT a good heat transfer fluid after the accelerated aging tests, this study results in differentiating most compatible materials. Thus according to our study, Jarytherm® DBT can be used in direct thermocline thermal energy storage applications when compatibility of the solid material has been demonstrated.
Physical compatibility of plazomicin with select i.v. drugs during simulated Y-site administration.
Asempa, Tomefa E; Avery, Lindsay M; Kidd, James M; Kuti, Joseph L; Nicolau, David P
2018-06-12
The results of a study to determine the physical compatibility of plazomicin sulfate solution during simulated Y-site administration with 92 i.v. drugs are reported. Plazomicin injection solution (500 mg/10 mL) was diluted in 0.9% sodium chloride or 5% dextrose for injection to a final volume of 50 mL (final plazomicin concentration, 24 mg/mL), consistent with a 15-mg/kg dose administered to an 80-kg patient (i.e., 1,200 mg). All other i.v. drugs were reconstituted according to manufacturers' recommendations and diluted with 0.9% sodium chloride or 5% dextrose for injection to the upper range of concentrations used clinically. Y-site conditions were simulated by mixing 5 mL of plazomicin solution with 5 mL of tested drug solutions in a 1:1 ratio. Solutions were assessed for visual (via color and Tyndall beam testing), turbidity (using a laboratory-grade turbidimeter), and pH changes over a 60-minute observation period. Incompatibility was defined a priori as precipitation, color change, a positive Tyndall test, or a turbidity change of ≥0.5 nephelometric turbidity units at any time during the 60-minute observation period. Plazomicin was physically compatible with 79 of the 92 drugs tested. Determinations of physical incompatibility with plazomicin were made for 13 drugs: albumin, amiodarone, amphotericin B deoxycholate, anidulafungin, calcium chloride, daptomycin, esomeprazole, heparin, levofloxacin, methylprednisolone, micafungin, phenytoin, and propofol, CONCLUSION: Plazomicin at a concentration of 24 mg/mL was physically compatible with 85% of the drugs tested, including 31 of 36 antimicrobial agents. Copyright © 2018 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
Dual mode operation, highly selective nanohole array-based plasmonic colour filters
NASA Astrophysics Data System (ADS)
Fouladi Mahani, Fatemeh; Mokhtari, Arash; Mehran, Mahdiyeh
2017-09-01
Taking advantage of nanostructured metal films as plasmonic colour filters (PCFs) has been evolved remarkably as an alternative to the conventional technologies of chemical colour filtering. However, most of the proposed PCFs depict a poor colour purity focusing on generating either the additive or subtractive colours. In this paper, we present dual mode operation PCFs employing an opaque aluminium film patterned with sub-wavelength holes. Subtractive colours like cyan, magenta, and yellow are the results of reflection mode of these filters yielding optical efficiencies as high as 70%-80% and full width at half maximum of the stop-bands up to 40-50 nm. The colour selectivity of the transmission mode for the additive colours is also significant due to their enhanced performance through the utilization of a relatively thick aluminium film in contact with a modified dielectric environment. These filters provide a simple design with one-step lithography in addition to compatibility with the conventional CMOS processes. Moreover, they are polarization insensitive due to their symmetric geometry. A complete palette of pure subtractive and additive colours has been realized with potential applications, such as multispectral imaging, CMOS image sensors, displays, and colour printing.
Measurement of damping and temperature: Precision bounds in Gaussian dissipative channels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Monras, Alex; Illuminati, Fabrizio
2011-01-15
We present a comprehensive analysis of the performance of different classes of Gaussian states in the estimation of Gaussian phase-insensitive dissipative channels. In particular, we investigate the optimal estimation of the damping constant and reservoir temperature. We show that, for two-mode squeezed vacuum probe states, the quantum-limited accuracy of both parameters can be achieved simultaneously. Moreover, we show that for both parameters two-mode squeezed vacuum states are more efficient than coherent, thermal, or single-mode squeezed states. This suggests that at high-energy regimes, two-mode squeezed vacuum states are optimal within the Gaussian setup. This optimality result indicates a stronger form ofmore » compatibility for the estimation of the two parameters. Indeed, not only the minimum variance can be achieved at fixed probe states, but also the optimal state is common to both parameters. Additionally, we explore numerically the performance of non-Gaussian states for particular parameter values to find that maximally entangled states within d-dimensional cutoff subspaces (d{<=}6) perform better than any randomly sampled states with similar energy. However, we also find that states with very similar performance and energy exist with much less entanglement than the maximally entangled ones.« less
Dual mode operation, highly selective nanohole array-based plasmonic colour filters.
Mahani, Fatemeh Fouladi; Mokhtari, Arash; Mehran, Mahdiyeh
2017-09-20
Taking advantage of nanostructured metal films as plasmonic colour filters (PCFs) has been evolved remarkably as an alternative to the conventional technologies of chemical colour filtering. However, most of the proposed PCFs depict a poor colour purity focusing on generating either the additive or subtractive colours. In this paper, we present dual mode operation PCFs employing an opaque aluminium film patterned with sub-wavelength holes. Subtractive colours like cyan, magenta, and yellow are the results of reflection mode of these filters yielding optical efficiencies as high as 70%-80% and full width at half maximum of the stop-bands up to 40-50 nm. The colour selectivity of the transmission mode for the additive colours is also significant due to their enhanced performance through the utilization of a relatively thick aluminium film in contact with a modified dielectric environment. These filters provide a simple design with one-step lithography in addition to compatibility with the conventional CMOS processes. Moreover, they are polarization insensitive due to their symmetric geometry. A complete palette of pure subtractive and additive colours has been realized with potential applications, such as multispectral imaging, CMOS image sensors, displays, and colour printing.
Convective and global stability analysis of a Mach 5.8 boundary layer grazing a compliant surface
NASA Astrophysics Data System (ADS)
Dettenrieder, Fabian; Bodony, Daniel
2016-11-01
Boundary layer transition on high-speed vehicles is expected to be affected by unsteady surface compliance. The stability properties of a Mach 5.8 zero-pressure-gradient laminar boundary layer grazing a nominally-flat thermo-mechanically compliant panel is considered. The linearized compressible Navier-Stokes equations describe small amplitude disturbances in the fluid while the panel deformations are described by the Kirchhoff-Love plate equation and its thermal state by the transient heat equation. Compatibility conditions that couple disturbances in the fluid to those in the solid yield simple algebraic and robin boundary conditions for the velocity and thermal states, respectively. A local convective stability analysis shows that the panel can modify both the first and second Mack modes when, for metallic-like panels, the panel thickness exceeds the lengthscale δ99 Rex- 0 . 5 . A global stability analysis, which permits finite panel lengths with clamped-clamped boundary conditions, shows a rich eigenvalue spectrum with several branches. Unstable modes are found with streamwise-growing panel deformations leading to Mach wave-type radiation. Stable global modes are also found and have distinctly different panel modes but similar radiation patterns. Air Force Office of Scientific Research.
Mode-converting coupler for silicon-on-sapphire devices
NASA Astrophysics Data System (ADS)
Zlatanovic, S.; Offord, B. W.; Owen, M.; Shimabukuro, R.; Jacobs, E. W.
2015-02-01
Silicon-on-sapphire devices are attractive for the mid-infrared optical applications up to 5 microns due to the low loss of both silicon and sapphire in this wavelength band. Designing efficient couplers for silicon-on-sapphire devices presents a challenge due to a highly confined mode in silicon and large values of refractive index of both silicon and sapphire. Here, we present design, fabrication, and measurements of a mode-converting coupler for silicon-on-sapphire waveguides. We utilize a mode converter layout that consists of a large waveguide that is overlays a silicon inverse tapered waveguide. While this geometry was previously utilized for silicon-on-oxide devices, the novelty is in using materials that are compatible with the silicon-on-sapphire platform. In the current coupler the overlaying waveguide is made of silicon nitride. Silicon nitride is the material of choice because of the large index of refraction and low absorption from near-infrared to mid-infrared. The couplers were fabricated using a 0.25 micron silicon-on-sapphire process. The measured coupling loss from tapered lensed silica fibers to the silicon was 4.8dB/coupler. We will describe some challenges in fabrication process and discuss ways to overcome them.
SAFARI optical system architecture and design concept
NASA Astrophysics Data System (ADS)
Pastor, Carmen; Jellema, Willem; Zuluaga-Ramírez, Pablo; Arrazola, David; Fernández-Rodriguez, M.; Belenguer, Tomás.; González Fernández, Luis M.; Audley, Michael D.; Evers, Jaap; Eggens, Martin; Torres Redondo, Josefina; Najarro, Francisco; Roelfsema, Peter
2016-07-01
SpicA FAR infrared Instrument, SAFARI, is one of the instruments planned for the SPICA mission. The SPICA mission is the next great leap forward in space-based far-infrared astronomy and will study the evolution of galaxies, stars and planetary systems. SPICA will utilize a deeply cooled 2.5m-class telescope, provided by European industry, to realize zodiacal background limited performance, and high spatial resolution. The instrument SAFARI is a cryogenic grating-based point source spectrometer working in the wavelength domain 34 to 230 μm, providing spectral resolving power from 300 to at least 2000. The instrument shall provide low and high resolution spectroscopy in four spectral bands. Low Resolution mode is the native instrument mode, while the high Resolution mode is achieved by means of a Martin-Pupplet interferometer. The optical system is all-reflective and consists of three main modules; an input optics module, followed by the Band and Mode Distributing Optics and the grating Modules. The instrument utilizes Nyquist sampled filled linear arrays of very sensitive TES detectors. The work presented in this paper describes the optical design architecture and design concept compatible with the current instrument performance and volume design drivers.
Espino, Orlando; Byrne, Ruth M J
2013-11-01
A new theory explains how people make hypothetical inferences from a premise consistent with several alternatives to a conclusion consistent with several alternatives. The key proposal is that people rely on a heuristic that identifies compatible possibilities. It is tested in 7 experiments that examine inferences between conditionals and disjunctions. Participants accepted inferences between conditionals and inclusive disjunctions when a compatible possibility was immediately available, in their binary judgments that a conclusion followed or not (Experiment 1a) and ternary judgments that included it was not possible to know (Experiment 1b). The compatibility effect was amplified when compatible possibilities were more readily available, e.g., for 'A only if B' conditionals (Experiment 2). It was eliminated when compatible possibilities were not available, e.g., for 'if and only if A B' bi-conditionals and exclusive disjunctions (Experiment 3). The compatibility heuristic occurs even for inferences based on implicit negation e.g., 'A or B, therefore if C D' (Experiment 4), and between universals 'All A's are B's' and disjunctions (Experiment 5a) and universals and conditionals (Experiment 5b). The implications of the results for alternative theories of the cognitive processes underlying hypothetical deductions are discussed. Copyright © 2013. Published by Elsevier Inc.
Vacuum-Compatible Wideband White Light and Laser Combiner Source System
NASA Technical Reports Server (NTRS)
Azizi, Alineza; Ryan, Daniel J.; Tang, Hong; Demers, Richard T.; Kadogawa, Hiroshi; An, Xin; Sun, George Y.
2010-01-01
For the Space Interferometry Mission (SIM) Spectrum Calibration Development Unit (SCDU) testbed, wideband white light is used to simulate starlight. The white light source mount requires extremely stable pointing accuracy (<3.2 microradians). To meet this and other needs, the laser light from a single-mode fiber was combined, through a beam splitter window with special coating from broadband wavelengths, with light from multimode fiber. Both lights were coupled to a photonic crystal fiber (PCF). In many optical systems, simulating a point star with broadband spectrum with stability of microradians for white light interferometry is a challenge. In this case, the cameras use the white light interference to balance two optical paths, and to maintain close tracking. In order to coarse align the optical paths, a laser light is sent into the system to allow tracking of fringes because a narrow band laser has a great range of interference. The design requirements forced the innovators to use a new type of optical fiber, and to take a large amount of care in aligning the input sources. The testbed required better than 1% throughput, or enough output power on the lowest spectrum to be detectable by the CCD camera (6 nW at camera). The system needed to be vacuum-compatible and to have the capability for combining a visible laser light at any time for calibration purposes. The red laser is a commercially produced 635-nm laser 5-mW diode, and the white light source is a commercially produced tungsten halogen lamp that gives a broad spectrum of about 525 to 800 nm full width at half maximum (FWHM), with about 1.4 mW of power at 630 nm. A custom-made beam splitter window with special coating for broadband wavelengths is used with the white light input via a 50-mm multi-mode fiber. The large mode area PCF is an LMA-8 made by Crystal Fibre (core diameter of 8.5 mm, mode field diameter of 6 mm, and numerical aperture at 625 nm of 0.083). Any science interferometer that needs a tracking laser fringe to assist in alignment can use this system.
Electronics systems test laboratory testing of shuttle communications systems
NASA Technical Reports Server (NTRS)
Stoker, C. J.; Bromley, L. K.
1985-01-01
Shuttle communications and tracking systems space to space and space to ground compatibility and performance evaluations are conducted in the NASA Johnson Space Center Electronics Systems Test Laboratory (ESTL). This evaluation is accomplished through systems verification/certification tests using orbiter communications hardware in conjunction with other shuttle communications and tracking external elements to evaluate end to end system compatibility and to verify/certify that overall system performance meets program requirements before manned flight usage. In this role, the ESTL serves as a multielement major ground test facility. The ESTL capability and program concept are discussed. The system test philosophy for the complex communications channels is described in terms of the major phases. Results of space to space and space to ground systems tests are presented. Several examples of the ESTL's unique capabilities to locate and help resolve potential problems are discussed in detail.
Preparation and Compatibility Evaluation of Polypropylene/High Density Polyethylene Polyblends
Lin, Jia-Horng; Pan, Yi-Jun; Liu, Chi-Fan; Huang, Chien-Lin; Hsieh, Chien-Teng; Chen, Chih-Kuang; Lin, Zheng-Ian; Lou, Ching-Wen
2015-01-01
This study proposes melt-blending polypropylene (PP) and high density polyethylene (HDPE) that have a similar melt flow index (MFI) to form PP/HDPE polyblends. The influence of the content of HDPE on the properties and compatibility of polyblends is examined by using a tensile test, flexural test, Izod impact test, scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), differential scanning calorimetry (DSC), polarized light microscopy (PLM), and X-ray diffraction (XRD). The SEM results show that PP and HDPE are incompatible polymers with PP being a continuous phase and HDPE being a dispersed phase. The FTIR results show that the combination of HDPE does not influence the chemical structure of PP, indicating that the polyblends are made of a physical blending. The DSC and XRD results show that PP and HDPE are not compatible, and the combination of HDPE is not correlated with the crystalline structure and stability of PP. The PLM results show that the combination of HDPE causes stacking and incompatibility between HDPE and PP spherulites, and PP thus has incomplete spherulite morphology and a smaller spherulite size. However, according to mechanical property test results, the combination of HDPE improves the impact strength of PP. PMID:28793750
Preparation and Compatibility Evaluation of Polypropylene/High Density Polyethylene Polyblends.
Lin, Jia-Horng; Pan, Yi-Jun; Liu, Chi-Fan; Huang, Chien-Lin; Hsieh, Chien-Teng; Chen, Chih-Kuang; Lin, Zheng-Ian; Lou, Ching-Wen
2015-12-17
This study proposes melt-blending polypropylene (PP) and high density polyethylene (HDPE) that have a similar melt flow index (MFI) to form PP/HDPE polyblends. The influence of the content of HDPE on the properties and compatibility of polyblends is examined by using a tensile test, flexural test, Izod impact test, scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), differential scanning calorimetry (DSC), polarized light microscopy (PLM), and X-ray diffraction (XRD). The SEM results show that PP and HDPE are incompatible polymers with PP being a continuous phase and HDPE being a dispersed phase. The FTIR results show that the combination of HDPE does not influence the chemical structure of PP, indicating that the polyblends are made of a physical blending. The DSC and XRD results show that PP and HDPE are not compatible, and the combination of HDPE is not correlated with the crystalline structure and stability of PP. The PLM results show that the combination of HDPE causes stacking and incompatibility between HDPE and PP spherulites, and PP thus has incomplete spherulite morphology and a smaller spherulite size. However, according to mechanical property test results, the combination of HDPE improves the impact strength of PP.
Seal Materials Compatible with the Electroplating Solvent Used in Constellation-X Mirrors
NASA Technical Reports Server (NTRS)
Pei, Xiong-Skiba
1999-01-01
The existing gasket seals used in electroplating of the Constellation-X mirrors are difficult to assemble, and the current seal material is hydrophobic and too thick. The combination of the above problems result in: 1) non-uniform plating; 2) defect sites such as pits on the mirror edges; 3) "bear claws" on the edges of the mandrels and mirrors causing difficulties in shell-mirror separations; and 4) leakage of the plating solution past the seals into the mandrel causing chemical etching of the mandrel interior. This paper reports the results of this summer study in searching for alternate seal materials chemically compatible with the electroplating solvent. Fifteen common elastomeric rubber seal materials made-by Parker Seals were investigated including butyl, ethylene propylene, fluorosilicone, nitrile, Viton fluorocarbon, and silicone. Test results showed that Viton fluorocarbon compounds as a group were superior to the other tested compounds for chemical compatibility with the plating bath.
New optical architecture for holographic data storage system compatible with Blu-ray Disc™ system
NASA Astrophysics Data System (ADS)
Shimada, Ken-ichi; Ide, Tatsuro; Shimano, Takeshi; Anderson, Ken; Curtis, Kevin
2014-02-01
A new optical architecture for holographic data storage system which is compatible with a Blu-ray Disc™ (BD) system is proposed. In the architecture, both signal and reference beams pass through a single objective lens with numerical aperture (NA) 0.85 for realizing angularly multiplexed recording. The geometry of the architecture brings a high affinity with an optical architecture in the BD system because the objective lens can be placed parallel to a holographic medium. Through the comparison of experimental results with theory, the validity of the optical architecture was verified and demonstrated that the conventional objective lens motion technique in the BD system is available for angularly multiplexed recording. The test-bed composed of a blue laser system and an objective lens of the NA 0.85 was designed. The feasibility of its compatibility with BD is examined through the designed test-bed.
Compatibility of refrigerants and lubricants with motor materials. Volume 1, Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Doerr, R.; Kujak, S.
This volume contains the abstract, scope, discussion of results, charts of motor material compatibility, test procedures, material identifications, and 84 pages of data summary tables. Compatibility test results for 11 pure refrigerants and 17 refrigerant-lubricant combinations with 24 motor materials are included. The greatest effect on the motor materials was caused by adsorption followed by desorption of refrigerants at higher temperatures. High internal pressure of the adsorbed refrigerants and their tendency to evolve from the materials resulted in blisters, cracks, internal bubbles in the varnish, and delamination or bubbles in the sheet insulations. The second effect was extraction or dissolutionmore » of materials that lead to embrittlement of some sheet insulations. HCFC-22 and HCFC- 22/mineral oil had the most deleterious effects; the materials are expected to be reliable when used with most of the new refrigerants and lubricants. Tables.« less
Analysis of structural dynamic data from Skylab. Volume 2: Skylab analytical and test model data
NASA Technical Reports Server (NTRS)
Demchak, L.; Harcrow, H.
1976-01-01
The orbital configuration test modal data, analytical test correlation modal data, and analytical flight configuration modal data are presented. Tables showing the generalized mass contributions (GMCs) for each of the thirty tests modes are given along with the two dimensional mode shape plots and tables of GMCs for the test correlated analytical modes. The two dimensional mode shape plots for the analytical modes and uncoupled and coupled modes of the orbital flight configuration at three development phases of the model are included.
2011-01-01
Background Integration of compatible or incompatible emotional valence and semantic information is an essential aspect of complex social interactions. A modified version of the Implicit Association Test (IAT) called Dual Valence Association Task (DVAT) was designed in order to measure conflict resolution processing from compatibility/incompatibly of semantic and facial valence. The DVAT involves two emotional valence evaluative tasks which elicits two forms of emotional compatible/incompatible associations (facial and semantic). Methods Behavioural measures and Event Related Potentials were recorded while participants performed the DVAT. Results Behavioural data showed a robust effect that distinguished compatible/incompatible tasks. The effects of valence and contextual association (between facial and semantic stimuli) showed early discrimination in N170 of faces. The LPP component was modulated by the compatibility of the DVAT. Conclusions Results suggest that DVAT is a robust paradigm for studying the emotional interference effect in the processing of simultaneous information from semantic and facial stimuli. PMID:21489277
Anderson, Collin; MacKay, Mark
2016-11-01
Calcium and phosphate precipitation is an ongoing concern when compounding pediatric parenteral nutrition (PN) solutions. Considerable effort has been expended in producing graphs, tables, and equations to guide the practitioner in prescribing PN that will remain stable. Calcium gluconate is preferred over calcium chloride when compounding PN because of its superior compatibility with inorganic phosphates. PN solutions containing calcium gluconate carry a higher aluminum load than equivalent solutions compounded with calcium chloride, leading to increased potential for aluminum toxicity. This study tested the solubility of calcium chloride in PN solutions compounded with an organic phosphate component, sodium glycerophosphate (NaGP), in place of sodium phosphate. Five PN solutions were compounded by adding calcium chloride at 10, 20, 30, 40, and 50 mEq/L and corresponding concentrations of NaGP at 10, 20, 30, 40, and 50 mmol/L. Each of the 5 solutions was compounded using 1.5% and 4% amino acids, cysteine, and lipids. The physical stability was evaluated by visual inspection (precipitation, haze, and color change). Solutions were evaluated microscopically for any microcrystals using U.S. Pharmacopeia <788> standards. Compatibility testing showed no changes in the PN solution in any of the concentrations tested. Calcium chloride was found to be physically compatible with NaGP in PN at the tested concentrations. Utilization of NaGP in PN solutions would eliminate the need for precipitation curves and allow for the use of calcium chloride. Compounding with NaGP and calcium chloride allows the practitioner a mechanism for reducing the aluminum load in PN. © 2015 American Society for Parenteral and Enteral Nutrition.
Characterization of a prototype MR-compatible Delta4 QA system in a 1.5 tesla MR-linac
NASA Astrophysics Data System (ADS)
de Vries, J. H. W.; Seravalli, E.; Houweling, A. C.; Woodings, S. J.; van Rooij, R.; Wolthaus, J. W. H.; Lagendijk, J. J. W.; Raaymakers, B. W.
2018-01-01
To perform patient plan quality assurance (QA) on a newly installed MR-linac (MRL) it is necessary to have an MR-compatible QA device. An MR compatible device (MR-Delta4) has been developed together with Scandidos AB (Uppsala, Sweden). The basic characteristics of the detector response, such as short-term reproducibility, dose linearity, field size dependency, dose rate dependency, dose-per-pulse dependency and angular dependency, were investigated for the clinical Delta4-PT as well as for the MR compatible version. All tests were performed with both devices on a conventional linac and the MR compatible device was tested on the MRL as well. No statistically significant differences were found in the short-term reproducibility (<0.1%), dose linearity (⩽0.5%), field size dependency (<2.0% for field sizes larger than 5 × 5 cm2), dose rate dependency (<1.0%) or angular dependency for any phantom/linac combination. The dose-per-pulse dependency (<0.8%) was found to be significantly different between the two devices. This difference can be explained by the fact that the diodes in the clinical Delta4-PT were irradiated with a much larger dose than the MR-Delta4-PT ones. The absolute difference between the devices (<0.5%) was found to be small, so no clinical impact is expected. For both devices, the results were consistent with the characteristics of the Delta4-PT device reported in the literature (Bedford et al 2009 Phys. Med. Biol. 54 N167-76 Sadagopan et al 2009 J. Appl. Clin. Med. Phys. 10 2928). We found that the characteristics of the MR compatible Delta4 phantom were found to be comparable to the clinically used one. Also, the found characteristics do not differ from the previously reported characteristics of the commercially available non-MR compatible Delta4-PT phantom. Therefore, the MR compatible Delta4 prototype was found to be safe and effective for use in the 1.5 tesla magnetic field of the Elekta MR-linac
EMC (Electromagnetic Compatibility) Standards Handbook. Revision 4,
1982-11-01
report was prepared by the lIT Research Institute as part of AF Project 649E under Contract F-19628-80-C-0042 with the Electronic Systems Division of...the Air Pbrce Systems Command in support of the DoD Electromagnetic Compatibility Analysis Center, Annapolis, Maryland. This report has been reviewed...3-1 "JVDE Organizations .. .0 . . . . . . . . . . . . . . . . . . . . . 3 1 VDE Testing Station
NASA Astrophysics Data System (ADS)
He, Chunli; Wang, Miao; Cai, Xianmei; Huang, Xiaobo; Li, Li; Zhu, Haomiao; Shen, Jian; Yuan, Jiang
2011-11-01
To improve hydrophilicity and blood compatibility properties of polyurethane (PU) film, we chemically induced graft copolymerization of 2-hydroxyethyl methacrylate (HEMA) onto the surface of polyurethane film using benzoyl peroxide as an initiator. The effects of grafting temperature, grafting time, monomer and initiator concentrations on the grafting yields were studied. The maximum grafting yield value was obtained 0.0275 g/cm2 for HEMA. Characterization of the films was carried out by attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR), water contact angle measurements. ATR-FTIR data showed that HEMA was successfully grafted onto the PU films surface. Water contact angle measurement demonstrated the grafted films possessed a relatively hydrophilic surface. The blood compatibility of the grafted films was preliminarily evaluated by a platelet-rich plasma adhesion test and hemolysis test. The results of platelet adhesion experiment showed that polyurethane grafted polymerization with monomer of 2-hydroxyethyl methacrylate had good blood compatibility featured by the low platelet adhesion. Hemolysis rate of the PU-g-PHEMA films was dramatically decreased than the ungrafted PU films. This kind of new biomaterials grafted with HEMA monomers might have a potential usage for biomedical applications.
Julstrom, Stephen; Kozma-Spytek, Linda; Isabelle, Scott
2011-09-01
During the revision of the American National Standards Institute (ANSI) C63.19 and the development of the ANSI/Telecommunications Industry Association-1083 hearing aid compatibility standards, it became evident that additional data concerning user acceptance of interfering magnetic noises generated by wireless and cordless telephones were needed in order to determine the requirements for telecoil-coupling compatibility. Further insight was needed into the magnetic signal-to-noise (S/N) ratios required to achieve specific levels of telephone usability by hearing aid wearers. (A companion article addresses magnetic signal level requirements.) Test subjects used their own hearing aids. The magnetic signals were applied through large magnetic head-worn coils, selected for the field orientation appropriate for each hearing aid. After adjusting their aid's volume control to an acoustic speech reference, the subjects adjusted the applied magnetic signal level to find their Most Comfortable Level (MCL). Each subject then adjusted the levels of six of eight different representative interfering noises to three levels of subjective telephone usability: "usable for a brief call," "acceptable for normal use," and "excellent performance." Each subject's objective noise audibility threshold in the presence of speech was also obtained for the various noise types. The 57 test subjects covered an age range of 22 to 79 yr, with a self-reported hearing loss duration of 12 to 72 yr. All had telecoils that they used for at least some telecommunications needs. The self-reported degree of hearing loss ranged from moderate to profound. A guided intake questionnaire yielded general background information for each subject. A test control box fed by prepared speech and noise recordings from computer files enabled the subject or the tester, depending on the portion of the test, to select A-weighting-normalized noise interference levels in 1.25 dB steps relative to the selected MCL. For each subject for each tested noise type, the values for the selected S/N ratios were recorded for the three categories of subjective usability and the objective noise threshold. About half of the test subjects needed a minimum 21 dB S/N ratio for them to consider their listening experience "acceptable for normal use" of a telephone. With a 30 dB S/N ratio, about 85% of the subjects reported normal use acceptability. Significant differences were apparent in the measured S/N user requirements among the noise types, though, indicating a deficiency in an A-weighted level measurement's ability to consistently predict the subjective acceptability of the various noises. An improved weighting function having both spectral and temporal components was developed to substantially eliminate these predictive inconsistencies. The interfering noise level that subjects chose for a telephone usability rating of "excellent performance" matched closely their objectively measured noise audibility threshold. A rating of "acceptable for normal use" was typically achieved at a 4 dB higher noise level, and a rating of "usable for a brief call," at a 10.4 dB higher noise level. These results did not relate significantly to noise type or to the subject's aided noise-in-speech hearing acuity. American Academy of Audiology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Denton, Mark A.
Under Task Order 22 of the industry Advisory and Assistance Services (A&AS) Contract to the Department of Energy (DOE) DE-NE0000291, AREVA has been tasked with providing assistance with engineering, analysis, cost estimating, and design support of a system for disposal of radioactive wastes in deep boreholes (without the use of radioactive waste). As part of this task order, AREVA was requested, through a letter of technical direction, to evaluate Sandia National Laboratory’s (SNL’s) waste package borehole emplacement system concept recommendation using input from DOE and SNL. This summary review report (SRR) documents this evaluation, with its focus on the primarymore » input document titled: “Deep Borehole Field Test Specifications/M2FT-15SN0817091” Rev. 1 [1], hereafter referred to as the “M2 report.” The M2 report focuses on the conceptual design development for the Deep Borehole Field Test (DBFT), mainly the test waste packages (WPs) and the system for demonstrating emplacement and retrieval of those packages in the Field Test Borehole (FTB). This SRR follows the same outline as the M2 report, which allows for easy correlation between AREVA’s review comments, discussion, potential proposed alternatives, and path forward with information established in the M2 report. AREVA’s assessment focused on three primary elements of the M2 report: the conceptual design of the WPs proposed for deep borehole disposal (DBD), the mode of emplacement of the WP into DBD, and the conceptual design of the DBFT. AREVA concurs with the M2 report’s selection of the wireline emplacement mode specifically over the drill-string emplacement mode and generically over alternative emplacement modes. Table 5-1 of this SRR compares the pros and cons of each emplacement mode considered viable for DBD. The primary positive characteristics of the wireline emplacement mode include: (1) considered a mature technology; (2) operations are relatively simple; (3) probability of a radiological release due to off-normal events are relatively low; (4) costs are relatively low; and (5) maintenance activities are relatively simple. The primary drawback associated with the wireline emplacement mode for DBD is the number of emplacement trips-in to the borehole, which results in a relatively higher probability for a drop event. Fortunately, the WPs can be engineered with impact limiters that will minimize the likelihood of a breach of the WP due to a drop. The WP designs presented in the M2 report appear to be focused on compatibility with the drill-string emplacement mode (e.g., the threaded connections). With the recommendation that the wireline emplacement mode be utilized for the DBFT, some changes may be warranted to these WPs. For example, the development of a WP release connection that is more reliable than the currently credited connection, which is considered to have a high failure probability, and the integration of an impact limiter into its design. The M2 report states the engineering demonstration of the DBFT will occur in the FTB over a 4-year period. AREVA recommends development and testing of the WP emplacement handling equipment occur separately (but concurrently, if not earlier) from the FTB at a mock-up facility. The separation of this activity would prevent schedule interference between the science and engineering thrusts of the project. Performing tests in a mock-up facility would allow additional control and observation compared to the FTB. The mock-up facility could also be utilized as a training facility for future operations. Terminal velocity and impact limiter testing would require the FTB for testing, since these areas would be difficult to reproduce in a limited depth mock-up. Although only at the end of the conceptual stage of design development, DBD appears to be a viable solution for some waste forms produced by the nuclear industry. However, regulatory requirements have yet to be established for pre- and post-closure performance of DBD and should be established as soon as possible. Some of the main areas of focus from a regulatory perspective include: (1) establishing acceptable performance requirements for the long-term behavior of DBD; (2) determining acceptable borehole abandonment criteria; (3) establishing retrievability requirements; (4) developing a consensus on the factor of safety (FoS) for the emplacement mode and WP; and (5) establishing safety and safeguards performance requirements for DBD. Although conservative requirements have been utilized to provide the foundation for the conceptual design of DBD, regulatory requirements and feedback are necessary to confirm recommendations made herein and to ensure the long-term performance of DBD is acceptable. The combination of the M2 report and this SRR is intended to facilitate the completion of the conceptual design for DBD for the Cs and Sr capsules and calcined waste forms. Using the conceptual design, preliminary design activities (the second stage of a three-stage process described in the M2 report) can proceed and the DBFT utilized to support, demonstrate, and confirm engineering elements of this design.« less
Visual compatibility of defibrotide with selected drugs during simulated Y-site administration.
Correard, Florian; Savry, Amandine; Gauthier-Villano, Laurence; Pisano, Pascale; Pourroy, Bertrand
2014-08-01
The visual compatibility of a solution of defibrotide (the only drug recommended for treatment and prophylaxis of hepatic venoocclusive disease) with solutions of various drugs commonly administered in bone marrow transplant procedures was studied. Solutions of 43 drug products in concentrations typically used in clinical practice were evaluated in 1:1 mixtures with defibrotide solution in glass tubes kept at room temperature. The evaluated products included antiinfectious, corticoid, sedative, analgesic, and cardiovascular agents widely used for hematopoietic stem cell transplantation and other marrow transplant procedures; in most cases, test solutions were prepared via dilution in or reconstitution with sterile water, 0.9% sodium chloride injection, or 5% dextrose injection. The mixtures were visually observed immediately after manual mixing and at specified time points (60, 150, and 240 minutes). Visual compatibility was defined as the absence of color change, haze, fibers, particles, gas generation, and precipitate formation. The effect of mixing order on visual compatibility was ascertained. Of the 43 tested drug solutions, 36 were found to be visually compatible with the defibrotide solution over the entire four-hour study period. Solutions of 7 drugs (amikacin, furosemide, midazolam, mycophenolate mofetil, nicardipine, tobramycin, and vancomycin) were visually incompatible with defibrotide solution. In some cases, evidence of incompatibility was observed intermittently or was dependent on mixing order. Defibrotide solution was found to be visually compatible with solutions of 36 i.v. products that are likely to be coadministered with the drug in a bone marrow transplant unit. Seven drug solutions were visually incompatible with defibrotide solution. Copyright © 2014 by the American Society of Health-System Pharmacists, Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Lee, J. A.; Chen, P. S.
2004-01-01
This Technical Memorandum describes the development of several high-strength aluminum (Al) alloys that are compatible with hydrogen peroxide (H2O2) propellant for NASA Hypersonic-X (Hyper-X) vehicles fuel tanks and structures. The yield strengths for some of these Al-magnesium-based alloys are more than 3 times stronger than the conventional 5254-H112 Al alloy, while maintaining excellent H2O2 compatibility similar to class 1 5254 alloy. The alloy development strategy is to add scandium, zirconium, and other transitional metals with unique electrochemical properties, which will not act as catalysts, to decompose the highly concentrated 90 percent H2O2. Test coupons are machined from sheet metals for H2O2 long-term exposure testing and mechanical properties testing. In addition, the ability to weld the new alloys using friction stir welding has also been explored. The new high-strength alloys could represent an enabling material technology for Hyper-X vehicles, where flight weight reduction is a critical requirement.
Poor Positive Predictive Value of Lyme Disease Serologic Testing in an Area of Low Disease Incidence
Lantos, Paul M.; Branda, John A.; Boggan, Joel C.; Chudgar, Saumil M.; Wilson, Elizabeth A.; Ruffin, Felicia; Fowler, Vance; Auwaerter, Paul G.; Nigrovic, Lise E.
2015-01-01
Background. Lyme disease is diagnosed by 2-tiered serologic testing in patients with a compatible clinical illness, but the significance of positive test results in low-prevalence regions has not been investigated. Methods. We reviewed the medical records of patients who tested positive for Lyme disease with standardized 2-tiered serologic testing between 2005 and 2010 at a single hospital system in a region with little endemic Lyme disease. Based on clinical findings, we calculated the positive predictive value of Lyme disease serology. Next, we reviewed the outcome of serologic testing in patients with select clinical syndromes compatible with disseminated Lyme disease (arthritis, cranial neuropathy, or meningitis). Results. During the 6-year study period 4723 patients were tested for Lyme disease, but only 76 (1.6%) had positive results by established laboratory criteria. Among 70 seropositive patients whose medical records were available for review, 12 (17%; 95% confidence interval, 9%–28%) were found to have Lyme disease (6 with documented travel to endemic regions). During the same time period, 297 patients with a clinical illness compatible with disseminated Lyme disease underwent 2-tiered serologic testing. Six of them (2%; 95% confidence interval, 0.7%–4.3%) were seropositive, 3 with documented travel and 1 who had an alternative diagnosis that explained the clinical findings. Conclusions. In this low-prevalence cohort, fewer than 20% of positive Lyme disease tests are obtained from patients with clinically likely Lyme disease. Positive Lyme disease test results may have little diagnostic value in this setting. PMID:26195017
40 CFR 1042.505 - Testing engines using discrete-mode or ramped-modal duty cycles.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Testing engines using discrete-mode or...-IGNITION ENGINES AND VESSELS Test Procedures § 1042.505 Testing engines using discrete-mode or ramped-modal... the Clean Air Act. (a) You may perform steady-state testing with either discrete-mode or ramped-modal...
NASA Astrophysics Data System (ADS)
Li, Xi; Lin, Qiu-han; Zhao, Xin-Ying; Han, Zhi-Wei; Wang, Bo-liang
2017-04-01
Thermal techniques (differential scanning calorimetry (DSC) and the vacuum stability test (VST)), according to STANAG 4147, and non-thermal techniques (Fourier transform infrared (FTIR) spectrometry and X-ray diffractometry (XRD)) were used to examine compatibility issues for 2,4,6,8,10,12-hexanitrohexaazaisowurtzitane (CL-20) with a selection of insensitive explosives, including nitroguanidine (NQ), 2,4,6-trinitrotoluene (TNT), 2,6-diamino-3,5-dinitropyridine-1-oxide (ANPyO), 2,4,6-triamino-1,3,5-trinitrobenzene (TATB), 3-nitro-1,2,4-triazol-5-one (NTO) and 2,6-diamino-3,5-dinitropyrazine-1-oxide (LLM-105). DSC measurements showed that ANPyO, TATB, NTO and LLM-105 were compatible with CL-20. The compatibility of CL-20/NQ, CL-20/TNT, CL-20/ANPyO, CL-20/TATB, CL-20/NTO and CL-20/LLM-105 mixtures was further explored using the VST, which revealed that all the selected insensitive explosives were compatible with CL-20. Possible chemical interactions were suspected for CL-20/TATB from the FTIR results and for CL-20/NTO from XRD analysis. In summary, ANPyO and LLM-105 demonstrated the optimal compatibility with CL-20.
Overhead tray for cable test system
NASA Technical Reports Server (NTRS)
Saltz, K. T.
1976-01-01
System consists of overhead slotted tray, series of compatible adapter cables, and automatic test set which consists of control console and cable-switching console. System reduces hookup time and also reduces cost of fabricating and storing test cables.
2014-01-01
Background The use of radio frequency identification (RFID) systems in healthcare is increasing, and concerns for electromagnetic compatibility (EMC) pose one of the biggest obstacles for widespread adoption. Numerous studies have demonstrated that RFID systems can interfere with medical devices; however, the majority of past studies relied on time-consuming and burdensome test schemes based on ad hoc test methods applied to individual RFID systems. Methods This paper presents the results of using an RFID simulator that allows for faster evaluation of RFID-medical device EMC against a library of RFID test signals at various field strengths. Results The results of these tests demonstrate the feasibility and adequacy of simulator testing and can be used to support its incorporation into applicable consensus standards. Conclusions This work can aid the medical device community in better assessing the risks associated with medical device exposure to RFID. PMID:25086451
Seidman, Seth J; Bekdash, Omar; Guag, Joshua; Mehryar, Maryam; Booth, Paul; Frisch, Paul
2014-08-03
The use of radio frequency identification (RFID) systems in healthcare is increasing, and concerns for electromagnetic compatibility (EMC) pose one of the biggest obstacles for widespread adoption. Numerous studies have demonstrated that RFID systems can interfere with medical devices; however, the majority of past studies relied on time-consuming and burdensome test schemes based on ad hoc test methods applied to individual RFID systems. This paper presents the results of using an RFID simulator that allows for faster evaluation of RFID-medical device EMC against a library of RFID test signals at various field strengths. The results of these tests demonstrate the feasibility and adequacy of simulator testing and can be used to support its incorporation into applicable consensus standards. This work can aid the medical device community in better assessing the risks associated with medical device exposure to RFID.
High performance waveguide-coupled Ge-on-Si linear mode avalanche photodiodes
Martinez, Nicholas J. D.; Derose, Christopher T.; Brock, Reinhard W.; ...
2016-08-09
Here, we present experimental results for a selective epitaxially grown Ge-on-Si separate absorption and charge multiplication (SACM) integrated waveguide coupled avalanche photodiode (APD) compatible with our silicon photonics platform. Epitaxially grown Ge-on-Si waveguide-coupled linear mode avalanche photodiodes with varying lateral multiplication regions and different charge implant dimensions are fabricated and their illuminated device characteristics and high-speed performance is measured. We report a record gain-bandwidth product of 432 GHz for our highest performing waveguide-coupled avalanche photodiode operating at 1510nm. Bit error rate measurements show operation with BER< 10 –12, in the range from –18.3 dBm to –12 dBm received optical powermore » into a 50 Ω load and open eye diagrams with 13 Gbps pseudo-random data at 1550 nm.« less
Programmable dispersion on a photonic integrated circuit for classical and quantum applications.
Notaros, Jelena; Mower, Jacob; Heuck, Mikkel; Lupo, Cosmo; Harris, Nicholas C; Steinbrecher, Gregory R; Bunandar, Darius; Baehr-Jones, Tom; Hochberg, Michael; Lloyd, Seth; Englund, Dirk
2017-09-04
We demonstrate a large-scale tunable-coupling ring resonator array, suitable for high-dimensional classical and quantum transforms, in a CMOS-compatible silicon photonics platform. The device consists of a waveguide coupled to 15 ring-based dispersive elements with programmable linewidths and resonance frequencies. The ability to control both quality factor and frequency of each ring provides an unprecedented 30 degrees of freedom in dispersion control on a single spatial channel. This programmable dispersion control system has a range of applications, including mode-locked lasers, quantum key distribution, and photon-pair generation. We also propose a novel application enabled by this circuit - high-speed quantum communications using temporal-mode-based quantum data locking - and discuss the utility of the system for performing the high-dimensional unitary optical transformations necessary for a quantum data locking demonstration.
The Modification of Cellulosic Surface with Fatty Acids via Plasma Mediated Reactions
NASA Astrophysics Data System (ADS)
Nada, Ahmed Ali Ahmed
Much attention has been paid recently to understand the healing process made by the human body, in order to develop new approaches for promoting healing. The wound healing process includes four main phases, namely, hemostatic, inflammatory, proliferation, and remodeling, which take place successively. The human body can provide all the requirements of the healing process in normal wounds, unless there is a kind of deficiency of the skin function or massive fluid losses of vast wounds. Therefore, wound care of non-healing wounds has recently been the growing concern of many applications. The goal of this work is to explore the development of a new cellulose-based wound dressing composite that contain or release wound healing agents attained via dry textile chemical finishing techniques (thermal curing-plasma treatment). The synthesis of different wound healing agents derived from fatty acids and attached chemically to cellulose or even delivered through cyclodextrine modified cellulose are reported in this work. First, free fatty acids, which are obtained from commercial vegetable oils, were identified as wound healing agents. Many of these free acids are known to bind with and deactivate the proteases associated with inflammation at a wound site. Linoleic acid is extracted from commercial products of safflower seed oil while ricinoleic acid is obtained from castor oil. Conjugated linoleic acid was synthesized. Un-conjugated linoleic acid was used to prepare two derivatives namely linoleic azide and allylic ketone of linoleic acid. Different cellulose derivatives such as cellulose peroxide, iododeoxycellulose and cellulose diazonium salt in different degree of substitutions were synthesized in order to facilitate the free radical reaction with the fatty acid derivatives. New modified cellulosic products were synthesized by reacting the cellulosic and the linoleic acid derivatives via thermal or plasma technique and characterized by FT-IR ATR, the wettability test, etc. The cyto-compatiability of the new product was investigated using the cytotoxicity test to identify the cytotoxic potentials of the grafted samples. The highest yield was obtained in the thermal curing (at 140°C, 3 min, and a 20% solution of azide derivative -- 170°C, 3 min, and a 2.5% solution of allylic ketone derivatives) of the iododeoxycellulose fabrics with either linoleic azide or the allylic ketone derivative. Atmospheric plasma machines were used for this study such as NCAPS (dielectric barrier discharge plasma) and APJeT. APJet plasma machine was used in two different modes namely downstream and in-situ. Although, the plasma treatment uses a lower energy to achieve the chemical reactions between the two components, the APJet obtained good results in the in-situ mode (at 800 Watts/cm3 RF power, 45 sec. exposure time) while retaining sufficient tensile strength. In general samples treated with the allylic ketone of linoleic acid treated samples showed higher graft yield than the azide derivative, especially those treated via thermal curing. Moreover, they are more cytologically compatible than the plasma treated samples. In the course of producing a wound healing product that contains or releases fatty acids, allylic beta-CD was synthesized for first time as a textile finishing agent. Per(2, 3, 6- tri-O-allyl)-beta-CD was synthesized and characterized using spectral analysis. Cellulosic derivatives were treated with per(2, 3, 6- tri-O-allyl)-beta-CD via either pad-thermofixation technique or plasma treatment. Thermal treatment showed superior efficiency over plasma techniques to activate the vinyl groups and creating a self-assembled CD network chemically bonded with the cellulose derivatives (at 180°C, 3 min, and a 20 % solution of Per(2, 3, 6- tri- O-allyl)-beta-CD). APJeT machine (in-situ mode) succeeded only to activate cellulose/ allylic CD reaction, but however, it could not offer enough energy to stimulate vinyl-vinyl reactions. Oleic acid with its semi-linear chemical structure tends to include in the CD cavity faster and to higher levels, than the others after 4 hrs at 25°C. At higher temperatures the equilibrium of free and included oleic acid shifts and a remarkable decrease in the total inclusion was observed. However, ricinoleic acid anions showed very poor tendency for inclusion either with high temperature or at long time which may be attributed to its chemical structure, which is too large for the CD cavities. Also, un-conjugated linoleic acid anions showed higher inclusion than the conjugated ones. MMT assay was used to determine the cyto- compatibility for the newly modified samples. Generally speaking, the highest fixation yields the highest cyto-compatibility of the treated samples. Iododeoxycellulose samples in both thermal and plasma curing reported high cyto-compatibility either with allylic ketone or azide derivative of linoleic acid over the other cellulose derivatives. Pure extracted fatty acids or included ones showed high cyto-compatibility towards L929 mouse cell line.
... red blood cells or anemia The recipient's and donor's blood are not compatible Urine tests show the presence ... Careful testing of donor and recipient blood types before transfusion or transplant can prevent this problem.
The oxygen sensitivity/compatibility ranking of several materials by different test methods
NASA Technical Reports Server (NTRS)
Lockhart, Billy J.; Bryan, Coleman J.; Hampton, Michael D.
1989-01-01
Eleven materials were evaluated for oxygen compatibility using the following test methods: heat of combustion (ASTM D 2015), liquid oxygen impact (ASTM D 2512), pneumatic impact (ASTM G 74), gaseous mechanical impact (ASTM G 86), autogenous ignition temperature by pressurized differential scanning calorimeter, and the determination of the 50 percent reaction level in liquid oxygen using silicon carbide as a reaction enhancer. The eleven materials evaluated were: Teflon TFE, Vespel SP-21, Krytox 240AC, Viton PLV5010B, Fluorel E2160, Kel F 81, Fluorogold, Fluorogreen E-600, Rulon A, Garlock 8573, nylon 6/6.
NASA Technical Reports Server (NTRS)
Gostowski, Rudy
2003-01-01
High-Test Hydrogen Peroxide (HTP) is receiving renewed interest as a monopropellant and as the oxidizer for bipropellant systems. HTP is hydrogen peroxide having concentrations ranging from 70 to 98%. In these applications the energy and oxygen released during decomposition of HTP is used for propulsion. In propulsion systems components must be fabricated and connected using available joining processes. Welding is a common joining method for metallic components. The goal of this study was to compare the HTP compatibility of welded vs. unwelded stainless steel.
NASA Technical Reports Server (NTRS)
Ratcliffe, James G.; Johnston, William M., Jr.
2014-01-01
Mixed mode I-mode II interlaminar tests were conducted on IM7/8552 tape laminates using the mixed-mode bending test. Three mixed mode ratios, G(sub II)/G(sub T) = 0.2, 0.5, and 0.8, were considered. Tests were performed at all three mixed-mode ratios under quasi-static and cyclic loading conditions, where the former static tests were used to determine initial loading levels for the latter fatigue tests. Fatigue tests at each mixed-mode ratio were performed at four loading levels, Gmax, equal to 0.5G(sub c), 0.4G(sub c), 0.3G(sub c), and 0.2G(sub c), where G(sub c) is the interlaminar fracture toughness of the corresponding mixed-mode ratio at which a test was performed. All fatigue tests were performed using constant-amplitude load control and delamination growth was automatically documented using compliance solutions obtained from the corresponding quasi-static tests. Static fracture toughness data yielded a mixed-mode delamination criterion that exhibited monotonic increase in Gc with mixed-mode ratio, G(sub II)/G(sub T). Fatigue delamination onset parameters varied monotonically with G(sub II)/G(sub T), which was expected based on the fracture toughness data. Analysis of non-normalized data yielded a monotonic change in Paris law exponent with mode ratio. This was not the case when normalized data were analyzed. Fatigue data normalized by the static R-curve were most affected in specimens tested at G(sub II)/G(sub T)=0.2 (this process has little influence on the other data). In this case, the normalized data yielded a higher delamination growth rate compared to the raw data for a given loading level. Overall, fiber bridging appeared to be the dominant mechanism, affecting delamination growth rates in specimens tested at different load levels and differing mixed-mode ratios.
Mirabelli, Mario F; Gionfriddo, Emanuela; Pawliszyn, Janusz; Zenobi, Renato
2018-02-12
We evaluated the performance of a dielectric barrier discharge ionization (DBDI) source for pesticide analysis in grape juice, a fairly complex matrix due to the high content of sugars (≈20% w/w) and pigments. A fast sample preparation method based on direct immersion solid-phase microextraction (SPME) was developed, and novel matrix compatible SPME fibers were used to reduce in-source matrix suppression effects. A high resolution LTQ Orbitrap mass spectrometer allowed for rapid quantification in full scan mode. This direct SPME-DBDI-MS approach was proven to be effective for the rapid and direct analysis of complex sample matrices, with limits of detection in the parts-per-trillion (ppt) range and inter- and intra-day precision below 30% relative standard deviation (RSD) for samples spiked at 1, 10 and 10 ng ml -1 , with overall performance comparable or even superior to existing chromatographic approaches.
Carbon nanotube-based three-dimensional monolithic optoelectronic integrated system
NASA Astrophysics Data System (ADS)
Liu, Yang; Wang, Sheng; Liu, Huaping; Peng, Lian-Mao
2017-06-01
Single material-based monolithic optoelectronic integration with complementary metal oxide semiconductor-compatible signal processing circuits is one of the most pursued approaches in the post-Moore era to realize rapid data communication and functional diversification in a limited three-dimensional space. Here, we report an electrically driven carbon nanotube-based on-chip three-dimensional optoelectronic integrated circuit. We demonstrate that photovoltaic receivers, electrically driven transmitters and on-chip electronic circuits can all be fabricated using carbon nanotubes via a complementary metal oxide semiconductor-compatible low-temperature process, providing a seamless integration platform for realizing monolithic three-dimensional optoelectronic integrated circuits with diversified functionality such as the heterogeneous AND gates. These circuits can be vertically scaled down to sub-30 nm and operates in photovoltaic mode at room temperature. Parallel optical communication between functional layers, for example, bottom-layer digital circuits and top-layer memory, has been demonstrated by mapping data using a 2 × 2 transmitter/receiver array, which could be extended as the next generation energy-efficient signal processing paradigm.
Drop-in compatible entanglement for optical-fiber networks.
Hall, Matthew A; Altepeter, Joseph B; Kumar, Prem
2009-08-17
A growing number of quantum communication protocols require entanglement distribution among remote parties, which is best accomplished by exploiting the mature technology and extensive infrastructure of low-loss optical fiber. For this reason, a practical source of entangled photons must be drop-in compatible with optical fiber networks. Here we demonstrate such a source for the first time, in which the nonlinearity of standard single-mode fiber is utilized to yield entangled photon pairs in the 1310-nm O-band. Using an ultra-stable design, we produce polarization entanglement with 98.0% +/- 0.5% fidelity to a maximally entangled state as characterized via coincidence-basis tomography. To demonstrate the source's drop-in capability, we transmit one photon from each entangled pair through a telecommunications-grade optical amplifier set to boost classical 1550-nm (C-band) communication signals. We verify that the photon pairs experience no measurable decoherence upon passing through the active amplifier (the output state's fidelity with a maximally entangled state is 98.4% +/- 1.4%). (c) 2009 Optical Society of America
A CMOS-Compatible, Low-Noise ISFET Based on High Efficiency Ion-Modulated Lateral-Bipolar Conduction
Chang, Sheng-Ren; Chen, Hsin
2009-01-01
Ion-sensitive, field-effect transistors (ISFET) have been useful biosensors in many applications. However, the signal-to-noise ratio of the ISFET is limited by its intrinsic, low-frequency noise. This paper presents an ISFET capable of utilizing lateral-bipolar conduction to reduce low-frequency noise. With a particular layout design, the conduction efficiency is further enhanced. Moreover, the ISFET is compatible with the standard CMOS technology. All materials above the gate-oxide are removed by simple, die-level post-CMOS process, allowing ions to modulate the lateral-bipolar current directly. By varying the gate-to-bulk voltage, the operation mode of the ISFET is controlled effectively, so is the noise performance measured and compared. Finally, the biasing conditions preferable for different low-noise applications are identified. Under the identified biasing condition, the signal-to-noise ratio of the ISFET as a pH sensor is proved to be improved by more than five times. PMID:22408508
Music and the brain - design of an MEG compatible piano.
Chacon-Castano, Julian; Rathbone, Daniel R; Hoffman, Rachel; Heng Yang; Pantazis, Dimitrios; Yang, Jason; Hornberger, Erik; Hanumara, Nevan C
2017-07-01
Magnetoencephalography (MEG) neuroimaging has been used to study subjects' responses when listening to music, but research into the effects of playing music has been limited by the lack of MEG compatible instruments that can operate in a magnetically shielded environment without creating electromagnetic interference. This paper describes the design and preliminary testing of an MEG compatible piano keyboard with 25 full size keys that employs a novel 3-state optical encoder design and electronics to provide realistic velocity-controlled volume modulation. This instrument will allow researchers to study musical performance on a finer timescale than fMRI and enable a range of MEG studies.
Preparation of anionic polyurethane nanoparticles and blood compatible behaviors.
Zhu, Qinshu; Wang, Yan; Zhou, Min; Mao, Chun; Huang, Xiaohua; Bao, Jianchun; Shen, Jian
2012-05-01
The anionic polyurethane nanoparticles (APU-NPs) were obtained by an emulsion polymerization method. It was found that the average size of the prepared APU-NPs is about 84 nm, and the APU-NPs have zeta-potential of -38.9 mV. The bulk characterization of synthesized APU-NPs was investigated by FTIR. The blood compatibility of APU-NPs was characterized by in vitro for coagulation tests, complement activation, platelet activation, cytotoxicity experiments, and hemolysis assay. The results showed that the APU-NPs synthesized in this paper are blood compatible with low level of cell cytotoxicity, and the results were significant for their potential use in vivo.
Oxygen fires, materials compatibility and system contaminants
NASA Astrophysics Data System (ADS)
Barter, Simon A.; Hillen, Lance W.
An evaluation is made of aircraft fires initiated by oxygen systems, giving attention to such systems' mechanical design and materials-selection factors. While many oxygen compatibility tests are conducted on single components, operational systems become contaminated through frequent use and occasional abuse; it is therefore essential for the designer to have information about the oxygen compatibility of the entire spectrum of potential contaminants and their various combinations. Valve designs are noted to be especially sensitive to system contamination. Gaseous oxygen fire severity is fundamentally determined by the period of oxygen flow. There is a clear need for an automatic shut-off device which would operate when abnormal flow conditions occur.
Advanced techniques for determining long term compatibility of materials with propellants
NASA Technical Reports Server (NTRS)
Green, R. L.; Stebbins, J. P.; Smith, A. W.; Pullen, K. E.
1973-01-01
A method for the prediction of propellant-material compatibility for periods of time up to ten years is presented. Advanced sensitive measurement techniques used in the prediction method are described. These include: neutron activation analysis, radioactive tracer technique, and atomic absorption spectroscopy with a graphite tube furnace sampler. The results of laboratory tests performed to verify the prediction method are presented.
International Symposium on Electromagnetic Compatibility, Wakefield, MA, August 20-22, 1985, Record
NASA Astrophysics Data System (ADS)
Various papers on electromagnetic compatibility are presented. The general topics addressed include: EMI transient/impulsive disturbances, electromagnetic shielding, antennas and propagation, measurement technology, anechoic chamber/open site measurements, communications systems, electrostatic discahrge, cables/transmission lines. Also considered are: elecromagnetic environments, antennas, electromagnetic pulse, nonlinear effect, computer/data transmission systems, EMI standards and requirements, enclosures/TEM cells, systems EMC, and test site measurements.
NASA Technical Reports Server (NTRS)
Herald, Stephen D.; Frisby, Paul M.; Davis, Samuel Eddie
2009-01-01
Safe and reliable seal materials for high-pressure oxygen systems sometimes appear to be extinct species when sought out by oxygen systems designers. Materials that seal well are easy to find, but these materials are typically incompatible with oxygen, especially in cryogenic liquid form. This incompatibility can result in seals that leak, or much worse, seals that easily ignite and burn during use. Materials that are compatible with oxygen are easy to find, such as the long list of compatible metals, but these metallic materials are limiting as seal materials. A material that seals well and is oxygen compatible has been the big game in the designer's safari. Scientists at the Materials Combustion Research Facility (MCRF), part of NASA/Marshall Space Flight Center (MSFC), are constantly searching for better materials and processes to improve the safety of oxygen systems. One focus of this effort is improving the characteristics of polymers used in the presence of an oxygen enriched environment. Very few systems can be built which contain no polymeric materials; therefore, materials which have good impact resistance, low heat of combustion, high auto-ignition temperature and that maintain good mechanical properties are essential. The scientists and engineers at the Materials Combustion Research Facility, in cooperation with seal suppliers, are currently testing a new formulation of polytetrafluoroethylene (PTFE) with Brass filler. This Brass-filled PTFE is showing great promise as a seal and seat material for high pressure oxygen systems. Early research has demonstrated very encouraging results, which could rank this material as one of the best fluorinated polymers ever tested. This paper will compare the data obtained for Brass-filled PTFE with other fluorinated polymers, such as TFE-Teflon (PTFE) , Kel-F 81, Viton A, Viton A-500, Fluorel , and Algoflon . A similar metal filled fluorinated polymer, Salox-M , was tested in comparison to Brass-filled PTFE to demonstrate the importance of the metal chosen and relative percentage of filler. General conclusions on the oxygen compatibility of this formulation are drawn, with an emphasis on comparing and contrasting the materials performance to the performance of the current state-of-the-art oxygen compatible polymers.
Seismology of rapidly rotating and solar-like stars
NASA Astrophysics Data System (ADS)
Reese, Daniel Roy
2018-05-01
A great deal of progress has been made in stellar physics thanks to asteroseismology, the study of pulsating stars. Indeed, asteroseismology is currently the only way to probe the internal structure of stars. The work presented here focuses on some of the theoretical aspects of this domain and addresses two broad categories of stars, namely solar-like pulsators (including red giants), and rapidly rotating pulsating stars. The work on solar-like pulsators focuses on setting up methods for efficiently characterising a large number of stars, in preparation for space missions like TESS and PLATO 2.0. In particular, the AIMS code applies an MCMC algorithm to find stellar properties and a sample of stellar models which fit a set of seismic and classic observational constraints. In order to reduce computation time, this code interpolates within a precalculated grid of models, using a Delaunay tessellation which allows a greater flexibility on the construction of the grid. Using interpolated models based on the outputs from this code or models from other forward modelling codes, it is possible to obtain refined estimates of various stellar properties such as the mean density thanks to inversion methods put together by me and G. Buldgen, my former PhD student. Finally, I show how inversion-type methods can also be used to test more qualitative information such as whether a decreasing rotation profile is compatible with a set of observed rotational splittings and a given reference model. In contrast to solar-like pulsators, the pulsation modes of rapidly rotating stars remain much more difficult to interpret due to the complexity of the numerical calculations needed to calculate such modes, the lack of simple frequency patterns, and the fact that it is difficult to predict mode amplitudes. The work described here therefore focuses on addressing the above difficulties one at a time in the hopes that it will one day be possible to carry out detailed asteroseismology in these stars. First of all, the non-adiabatic pulsation equations and their numerical implementation are described. The variational principle and work integrals are addressed. This is followed by a brief classification of the pulsation modes one can expect in rapidly rotating stars. I then address the frequencies patterns resulting from acoustic island modes and the interpretations of observed pulsation spectra based on these. This is then followed by a description of mode identification techniques and the ongoing efforts to adapt them to rapid rotation. Finally, the last part briefly deals with mode excitation.
DOT National Transportation Integrated Search
2016-10-14
Milestones Since Last Workshop - Finalized GPS/GNSS receiver test plan and test procedures - Coordinated government and manufacturer participation and executed Non-Disclosure Agreements (NDAs) - Developed/validated radiated RF test environment - Carr...
Inductive interference in rapid transit signaling systems. volume 2. suggested test procedures.
DOT National Transportation Integrated Search
1987-03-31
These suggested test procedures have been prepared in order to develop standard methods of analysis and testing to quantify and resolve issues of electromagnetic compatibility in rail transit operations. Electromagnetic interference, generated by rai...
NASA Technical Reports Server (NTRS)
Li, Jian; OBrien, T. Kevin; Lee, Shaw Ming
1997-01-01
Monotonic and fatigue tests were performed to compare the Mode II and III interlaminar fracture toughness and fatigue delamination onset for Tenax-HTA/R6376 carbon/toughened epoxy composites. The Mode II interlaminar fracture toughness and fatigue delamination onset were characterized using the end-notched flexure (ENF) test while the Mode III interlaminar fracture toughness and fatigue delamination onset were characterized by using the edge crack torsion (ECT) test. Monotonic tests show that the Mode III fracture toughness is higher than the Mode II fracture toughness. Both Mode II and III cyclic loading greatly increases the tendency for a delamination to grow relative to a single monotonically increasing load. Under fatigue loading, the Mode III specimen also has a longer life than the Mode II specimen.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bortolon, A.; Maingi, R.; Mansfield, D. K.
A newly installed Lithium Granule Injector (LGI) was used to pace edge localized modes (ELM) in DIII-D. ELM pacing efficiency was studied injecting lithium granules of nominal diameter 0.3–0.9mm, speed of 50–120 m s -1 and average injection rates up to 100 Hz for 0.9mm granules and up to 700 Hz for 0.3mm granules. The efficiency of ELM triggering was found to depend strongly on size of the injected granules, with triggering efficiency close to 100% obtained with 0.9mm diameter granules, lower with smaller sizes, and weakly depending on granule velocity. Robust ELM pacing was demonstrated in ITER-like plasmas formore » the entire shot length, at ELM frequencies 3–5 times larger than the ‘natural’ ELM frequency observed in reference discharges. Within the range of ELM frequencies obtained, the peak ELM heat flux at the outer strike point was reduced with increasing pacing frequency. The peak heat flux reduction at the inner strike point appears to saturate at high pacing frequency. Lithium was found in the plasma core, with a concurrent reduction of metallic impurities and carbon. Altogether, high frequency ELM pacing using the lithium granule injection appears to be compatible with both H-mode energy confinement and attractive H-mode pedestal characteristics, but further assessment is need« less
Visualizing Infrared (IR) Spectroscopy with Computer Animation
NASA Technical Reports Server (NTRS)
Abrams, Charles B.; Fine, Leonard W.
1996-01-01
IR Tutor, an interactive, animated infrared (IR) spectroscopy tutorial has been developed for Macintosh and IBM-compatible computers. Using unique color animation, complicated vibrational modes can be introduced to beginning students. Rules governing the appearance of IR absorption bands become obvious because the vibrational modes can be visualized. Each peak in the IR spectrum is highlighted, and the animation of the corresponding normal mode can be shown. Students can study each spectrum stepwise, or click on any individual peak to see its assignment. Important regions of each spectrum can be expanded and spectra can be overlaid for comparison. An introduction to the theory of IR spectroscopy is included, making the program a complete instructional package. Our own success in using this software for teaching and research in both academic and industrial environments will be described. IR Tutor consists of three sections: (1) The 'Introduction' is a review of basic principles of spectroscopy. (2) 'Theory' begins with the classical model of a simple diatomic molecule and is expanded to include larger molecules by introducing normal modes and group frequencies. (3) 'Interpretation' is the heart of the tutorial. Thirteen IR spectra are analyzed in detail, covering the most important functional groups. This section features color animation of each normal mode, full interactivity, overlay of related spectra, and expansion of important regions. This section can also be used as a reference.
Bortolon, A.; Maingi, R.; Mansfield, D. K.; ...
2016-04-08
A newly installed Lithium Granule Injector (LGI) was used to pace edge localized modes (ELM) in DIII-D. ELM pacing efficiency was studied injecting lithium granules of nominal diameter 0.3–0.9mm, speed of 50–120 m s -1 and average injection rates up to 100 Hz for 0.9mm granules and up to 700 Hz for 0.3mm granules. The efficiency of ELM triggering was found to depend strongly on size of the injected granules, with triggering efficiency close to 100% obtained with 0.9mm diameter granules, lower with smaller sizes, and weakly depending on granule velocity. Robust ELM pacing was demonstrated in ITER-like plasmas formore » the entire shot length, at ELM frequencies 3–5 times larger than the ‘natural’ ELM frequency observed in reference discharges. Within the range of ELM frequencies obtained, the peak ELM heat flux at the outer strike point was reduced with increasing pacing frequency. The peak heat flux reduction at the inner strike point appears to saturate at high pacing frequency. Lithium was found in the plasma core, with a concurrent reduction of metallic impurities and carbon. Altogether, high frequency ELM pacing using the lithium granule injection appears to be compatible with both H-mode energy confinement and attractive H-mode pedestal characteristics, but further assessment is need« less
NASA Wiring for Space Applications Program: Fiscal year 1994 - 1995 testing activities
NASA Technical Reports Server (NTRS)
Johnson, Harry T.; Hirsch, David
1995-01-01
The results of the testing of wire insulation materials for space applications is presented in this report. The wire insulations tested were partially fluorinated polyimide, extruded ETFE, extruded PTFE, PTFE tape, and PTFE/Kapton. The tests performed were flammability tests, odor tests, compatibility tests with aerospace fluids, offgassing tests, and thermal vacuum stability tests.
NASA Wiring for Space Applications Program: Fiscal year 1994 - 1995 testing activities
NASA Astrophysics Data System (ADS)
Johnson, Harry T.; Hirsch, David
1995-11-01
The results of the testing of wire insulation materials for space applications is presented in this report. The wire insulations tested were partially fluorinated polyimide, extruded ETFE, extruded PTFE, PTFE tape, and PTFE/Kapton. The tests performed were flammability tests, odor tests, compatibility tests with aerospace fluids, offgassing tests, and thermal vacuum stability tests.
42 CFR 493.959 - Immunohematology.
Code of Federal Regulations, 2014 CFR
2014-10-01
... challenges per testing event a program must provide for each analyte or test procedure is five. Analyte or... Compatibility testing Antibody identification (d) Evaluation of a laboratory's analyte or test performance. HHS... program must compare the laboratory's response for each analyte with the response that reflects agreement...
42 CFR 493.959 - Immunohematology.
Code of Federal Regulations, 2013 CFR
2013-10-01
... challenges per testing event a program must provide for each analyte or test procedure is five. Analyte or... Compatibility testing Antibody identification (d) Evaluation of a laboratory's analyte or test performance. HHS... program must compare the laboratory's response for each analyte with the response that reflects agreement...
42 CFR 493.959 - Immunohematology.
Code of Federal Regulations, 2012 CFR
2012-10-01
... challenges per testing event a program must provide for each analyte or test procedure is five. Analyte or... Compatibility testing Antibody identification (d) Evaluation of a laboratory's analyte or test performance. HHS... program must compare the laboratory's response for each analyte with the response that reflects agreement...
42 CFR 493.959 - Immunohematology.
Code of Federal Regulations, 2011 CFR
2011-10-01
... challenges per testing event a program must provide for each analyte or test procedure is five. Analyte or... Compatibility testing Antibody identification (d) Evaluation of a laboratory's analyte or test performance. HHS... program must compare the laboratory's response for each analyte with the response that reflects agreement...
NASA Technical Reports Server (NTRS)
Li, Jian; Lee, Edward W.; OBrien, T. Kevin; Lee, Shaw Ming
1996-01-01
An analytical and experimental investigation was carried out on G40-800/R6376 graphite epoxy laminates to evaluate the Edge Crack Torsion (ECT) test as a candidate for a standard Mode 3 interlaminar fracture toughness test for laminated composites. The ECT test consists of a (90/(+/- 45)(sub 3)/(+/- 45)(sub 3)/90))(sub s) laminate with a delamination introduced by a non-adhesive film at the mid-plane along one edge and loaded in a special fixture to create torsion along the length of the laminate. Dye penetrate enhanced X-radiograph of failed specimens revealed that the delamination initiated at the middle of the specimen length and propagated in a self similar manner along the laminate mid-plane. A three-dimensional finite element analysis was performed that indicated that a pure Mode 3 delamination exists at the middle of specimen length away from both ends. At the ends near the loading point a small Mode 2 component exists. However, the magnitude of this Mode 2 strain energy release rate at the loading point is small compared to the magnitude of Mode 3 component in the mid-section of the specimen. Hence, the ECT test yielded the desired Mode 3 delamination. The Mode 3 fracture toughness was obtained from a compliance calibration method and was in good agreement with the finite element results. Mode 2 End-Notched Flexure (ENF) tests and Mode 1 Double Cantilever Beam (DCB) tests were also performed for the same composite material. The Mode 1 fracture toughness was much smaller than both the Mode 2 and Mode 3 fracture toughness. The Mode 2 fracture toughness was found to be 75% of the Mode 3 fracture toughness.
Contractor point of view for system development and test program
NASA Technical Reports Server (NTRS)
Koide, F. K.; Ringer, D. E.; Earl, C. E.
1981-01-01
Industry's practice of testing space qualified hardware is examined. An overview of the Global Positioning System (GPS) Test Program is discussed from the component level to the sub-system compatibility tests with the space vehicle and finally to the launch site tests, all related to the Rubidium clock.
The perceived compatibility of safety and production expectations in hazardous occupations.
McLain, David L; Jarrell, Kimberly A
2007-01-01
Safety hazards are unavoidable in many work environments. Employees must be both productive and safe, however, conflicting safety and production demands can negatively affect safety, production, or both. The employee's perception of the compatibility of management's safety and production expectations is a possible predictor of such consequences. This paper defines "safety-production compatibility" and describes how measures of safety-production compatibility, as well as safety pressure and production pressure, were developed. We used LISREL structural equation modeling to test the influences of safety-production compatibility, safety pressure, and production pressure on safe work behavior and interference with performing other work tasks. The 239 study participants were workers employed in diverse but hazardous occupations. Pressure to work safely was positively associated with safe work behavior. The perceived compatibility of safety and production demands positively influenced safe work behavior and reduced the interference of safety hazards performing other tasks. Safety-production compatibility was also found to mediate the relationship between trust in management and safe work behavior. The results of this field study suggest increased compatibility, and thus less conflict, between safety and production demands influences safe work behavior and the interference of safety hazards with performing other work tasks. More broadly, the worker's reaction to multiple work demands is a safety and performance influence. Safety management efforts that focus only on the hazards fail to eliminate many accidents because accidents arise from many factors including technology, safety climate, social influences, production, and safety demands. This study suggests that workers differ in their perception of the compatibility of safety and production demands. These differences will show up in safe work behavior, influencing the effectiveness of safety management efforts and the trust workers have in management's concern for safety.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lopez-Ferrer, Daniel; Petritis, Konstantinos; Robinson, Errol W.
2011-02-01
Integrated top-down bottom-up proteomics combined with online digestion has great potential to improve the characterization of protein isoforms in biological systems and is amendable to highthroughput proteomics experiments. Bottom-up proteomics ultimately provides the peptide sequences derived from the tandem MS analyses of peptides after the proteome has been digested. Top-down proteomics conversely entails the MS analyses of intact proteins for more effective characterization of genetic variations and/or post-translational modifications (PTMs). Herein, we describe recent efforts towards efficient integration of bottom-up and top-down LCMS based proteomic strategies. Since most proteomic platforms (i.e. LC systems) operate in acidic environments, we exploited themore » compatibility of the pepsin (i.e. the enzyme’s natural acidic activity) for the integration of bottom-up and top-down proteomics. Pressure enhanced pepsin digestions were successfully performed and characterized with several standard proteins in either an offline mode using a Barocycler or an online mode using a modified high pressure LC system referred to as a fast online digestion system (FOLDS). FOLDS was tested using pepsin and a whole microbial proteome, and the results compared against traditional trypsin digestions on the same platform. Additionally, FOLDS was integrated with a RePlay configuration to demonstrate an ultra-rapid integrated bottom-up top-down proteomic strategy employing a standard mixture of proteins and a monkey pox virus proteome.« less
Codec-on-Demand Based on User-Level Virtualization
NASA Astrophysics Data System (ADS)
Zhang, Youhui; Zheng, Weimin
At work, at home, and in some public places, a desktop PC is usually available nowadays. Therefore, it is important for users to be able to play various videos on different PCs smoothly, but the diversity of codec types complicates the situation. Although some mainstream media players can try to download the needed codec automatically, this may fail for average users because installing the codec usually requires administrator privileges to complete, while the user may not be the owner of the PC. We believe an ideal solution should work without users' intervention, and need no special privileges. This paper proposes such a user-friendly, program-transparent solution for Windows-based media players. It runs the media player in a user-mode virtualization environment, and then downloads the needed codec on-the-fly. Because of API (Application Programming Interface) interception, some resource-accessing API calls from the player will be redirected to the downloaded codec resources. Then from the viewpoint of the player, the necessary codec exists locally and it can handle the video smoothly, although neither system registry nor system folders was modified during this process. Besides convenience, the principle of least privilege is maintained and the host system is left clean. This paper completely analyzes the technical issues and presents such a prototype which can work with DirectShow-compatible players. Performance tests show that the overhead is negligible. Moreover, our solution conforms to the Software-As-A-Service (SaaS) mode, which is very promising in the Internet era.
The multi-mode modulator: A versatile fluidic device for two-dimensional gas chromatography.
Seeley, John V; Schimmel, Nicolaas E; Seeley, Stacy K
2018-02-09
A fluidic device called the multi-mode modulator (MMM) has been developed for use as a comprehensive two-dimensional gas chromatography (GC x GC) modulator. The MMM can be employed in a wide range of capacities including as a traditional heart-cutting device, a low duty cycle GC x GC modulator, and a full transfer GC x GC modulator. The MMM is capable of producing narrow component pulses (widths <50ms) while operating at flows compatible with high resolution chromatography. The sample path of modulated components is confined to the interior of a joining capillary. The joining capillary dimensions and the position of the columns within the joining capillary can be optimized for the selected modulation mode. Furthermore, the joining capillary can be replaced easily and inexpensively if it becomes fouled due to sample matrix components or column bleed. The principles of operation of the MMM are described and its efficacy is demonstrated as a heart-cutting device and as a GC x GC modulator. Copyright © 2017 Elsevier B.V. All rights reserved.
Tian, Zhen; Yuan, Jingqi; Zhang, Xiang; Kong, Lei; Wang, Jingcheng
2018-05-01
The coordinated control system (CCS) serves as an important role in load regulation, efficiency optimization and pollutant reduction for coal-fired power plants. The CCS faces with tough challenges, such as the wide-range load variation, various uncertainties and constraints. This paper aims to improve the load tacking ability and robustness for boiler-turbine units under wide-range operation. To capture the key dynamics of the ultra-supercritical boiler-turbine system, a nonlinear control-oriented model is developed based on mechanism analysis and model reduction techniques, which is validated with the history operation data of a real 1000 MW unit. To simultaneously address the issues of uncertainties and input constraints, a discrete-time sliding mode predictive controller (SMPC) is designed with the dual-mode control law. Moreover, the input-to-state stability and robustness of the closed-loop system are proved. Simulation results are presented to illustrate the effectiveness of the proposed control scheme, which achieves good tracking performance, disturbance rejection ability and compatibility to input constraints. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Zhu, Danfeng; Zhang, Jinqiannan; Ye, Han; Yu, Zhongyuan; Liu, Yumin
2018-07-01
We propose a design of reciprocal optical diode based on asymmetric spatial mode conversion in multimode silicon waveguide on the silicon-on-insulator platform. The design possesses large bandwidth, high contrast ratio and high fabrication tolerance. The forward even-to-odd mode conversion and backward blockade of even mode are achieved by partial depth etching in the functional region. Simulated by three-dimension finite-difference time-domain method, the forward transmission efficiency is about -2.05 dB while the backward transmission efficiency is only -22.68 dB, reaching a highest contrast ratio of 0.983 at the wavelength of 1550 nm. The operational bandwidth is up to 200 nm (from 1450 nm to 1650 nm) with contrast ratio higher than 0.911. The numerical analysis also demonstrates that the proposed optical diode possesses high tolerance for geometry parameter errors which may be introduced in fabrication. The design based on partial depth etching is compatible with CMOS process and is expected to contribute to the silicon-based all-optical circuits.
Biocybernetic system evaluates indices of operator engagement in automated task
NASA Technical Reports Server (NTRS)
Pope, A. T.; Bogart, E. H.; Bartolome, D. S.
1995-01-01
A biocybernetic system has been developed as a method to evaluate automated flight deck concepts for compatibility with human capabilities. A biocybernetic loop is formed by adjusting the mode of operation of a task set (e.g., manual/automated mix) based on electroencephalographic (EEG) signals reflecting an operator's engagement in the task set. A critical issue for the loop operation is the selection of features of the EEG to provide an index of engagement upon which to base decisions to adjust task mode. Subjects were run in the closed-loop feedback configuration under four candidate and three experimental control definitions of an engagement index. The temporal patterning of system mode switching was observed for both positive and negative feedback of the index. The indices were judged on the basis of their relative strength in exhibiting expected feedback control system phenomena (stable operation under negative feedback and unstable operation under positive feedback). Of the candidate indices evaluated in this study, an index constructed according to the formula, beta power/(alpha power + theta power), reflected task engagement best.
Compatibility of elastomers in alternate jet fuels
NASA Technical Reports Server (NTRS)
Kalfayan, S. H.; Fedors, R. F.; Reilly, W. W.
1979-01-01
The compatibility of elastomeric compositions of known resistance to aircraft fuels was tested for potential use in Jet A type fuels obtainable from alternate sources, such as coal. Since such fuels were not available at the time, synthetic alternate fuels were prepared by adding tetralin to a petroleum based Jet A type fuel to simulate coal derived fuels which are expected to contain higher amounts of aromatic and hydroaromatic hydrocarbons. The elastomeric compounds tested were based on butadiene-acrylonitrile rubber, a castable Thiokol polysulfide rubber, and a castable fluorosilicone rubber. Batches of various cross-link densities of these rubbers were made and their chemical stress relaxation behavior in fuel, air, and nitrogen, their swelling properties, and response to mechanical testing were determined.
Power processor for a 30cm ion thruster
NASA Technical Reports Server (NTRS)
Biess, J. J.; Inouye, L. Y.
1974-01-01
A thermal vacuum power processor for the NASA Lewis 30cm Mercury Ion Engine was designed, fabricated and tested to determine compliance with electrical specifications. The power processor breadboard used the silicon controlled rectifier (SCR) series resonant inverter as the basic power stage to process all the power to an ion engine. The power processor includes a digital interface unit to process all input commands and internal telemetry signals so that operation is compatible with a central computer system. The breadboard was tested in a thermal vacuum environment. Integration tests were performed with the ion engine and demonstrate operational compatibility and reliable operation without any component failures. Electromagnetic interference data were also recorded on the design to provide information on the interaction with total spacecraft.
Testing the statistical compatibility of independent data sets
NASA Astrophysics Data System (ADS)
Maltoni, M.; Schwetz, T.
2003-08-01
We discuss a goodness-of-fit method which tests the compatibility between statistically independent data sets. The method gives sensible results even in cases where the χ2 minima of the individual data sets are very low or when several parameters are fitted to a large number of data points. In particular, it avoids the problem that a possible disagreement between data sets becomes diluted by data points which are insensitive to the crucial parameters. A formal derivation of the probability distribution function for the proposed test statistics is given, based on standard theorems of statistics. The application of the method is illustrated on data from neutrino oscillation experiments, and its complementarity to the standard goodness-of-fit is discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leonard, Philip; Francois, Elizabeth Green
During this project we investigated a number of energetic materials both old and new and determined that most of them were unsuitable due to safety or sensitivity reasons. Unsuccessful coformulants include TNAZ and BNFF for volatility reasons, and DAAF due to thermal compatibility issues. The powerful explosive HMX became a focus of the work in later stages as it conferred excellent power while being commonly available in well-regulated particle size lots and is chemically compatible in the melt with many coformulants. Ultimately three preferred formulations emerged from this work: a formulation tested on large scale by ARDEC involving PrNQ andmore » HMX; a formulation tested at ARDEC and LANL using a nitrate salt eutectic and HMX; a formulation tested at LANL using LLM-201 and HMX.« less
Code of Federal Regulations, 2010 CFR
2010-07-01
... this section for how to adjust discrete-mode testing. For this section, “regeneration” means an... ramped-modal cycle, or on average less than once per typical mode in a discrete-mode test. (a) Developing... modes of a discrete-mode steady-state test. You may use either of the following different approaches for...
Oxygen Compatibility Testing of Composite Materials
NASA Technical Reports Server (NTRS)
Engel, Carl D.; Watkins, Casey N.
2006-01-01
Composite materials offer significant weight-saving potential for aerospace applications in propellant and oxidizer tanks. This application for oxygen tanks presents the challenge of being oxygen compatible in addition to complying with the other required material characteristics. This effort reports on the testing procedures and data obtained in examining and selecting potential composite materials for oxygen tank usage. Impact testing of composites has shown that most of these materials initiate a combustion event when impacted at 72 ft-lbf in the presence of liquid oxygen, though testing has also shown substantial variability in reaction sensitivities to impact. Data for screening of 14 potential composites using the Bruceton method is given herein and shows that the 50-percent reaction frequencies range from 17 to 67 ft-lbf. The pressure and temperature rises for several composite materials were recorded to compare the energy releases as functions of the combustion reactions with their respective reaction probabilities. The test data presented are primarily for a test pressure of 300 psia in liquid oxygen. The impact screening process is compared with oxygen index and autogenous ignition test data for both the composite and the basic resin. The usefulness of these supplemental tests in helping select the most oxygen compatible materials is explored. The propensity for mechanical impact ignition of the composite compared with the resin alone is also examined. Since an ignition-free composite material at the peak impact energy of 72 ft-lbf has not been identified, composite reactivity must be characterized over the impact energy level and operating pressure ranges to provide data for hazard analyses in selecting the best potential material for liquid tank usage.
NASA Technical Reports Server (NTRS)
Strickland, John W.; Davis, S. Eddie
1995-01-01
The elimination of CFC-containing cleaning solvents for oxygen systems has prompted the development of a number of alternative cleaning solvents that must now be evaluated not only for cleanability, but compatibility as well. NASA Handbook 8060.1(NHB 8060.1) establishes the requirements for evaluation, testing, and selection of materials for use in oxygen rich environments. Materials intended for use in space vehicles, specified test facilities, and ground support equipment must meet the requirements of this document. In addition to the requirements of NHB 8060.1 for oxygen service, alternative cleaning solvents must also be evaluated in other areas (such as corrosivity, non-metals compatibility, non-volatile residue contamination, etc.). This paper will discuss the testing requirements of NHB 8060.1 and present preliminary results from early screening tests performed at Marshall Space Flight Center's Materials Combustion Research Facility.
Compatability of dispersion-strengthened platinum with resistojet propellants
NASA Technical Reports Server (NTRS)
Whalen, Margaret V.; Nathal, Michael V.
1987-01-01
Resistojets for the Space Station require long life and multipropellant capability. The choice of available materials to meet these requirements is limited. Dispersion-strengthened platinum was selected. Past results indicated that it should be suffieiently inert in candidate propellant environments and should be capable of operating at moderate temperatures for extended periods. A series of propellant compatibility tests was done with platinum strengthened with either yttria or zirconia. Data presented included the results of 1000-hr tests in CO2, H2, ammonia (NH3), N2, steam, hydrazine (N2H4), and methane (CH4); and 2000-hr tests in H2 and NH3. The platinum samples were tested at 1400 C in CO2, H2, NH3, N2, steam, and N2H4; at 500 C in CH4; and at 800 C in N2H4. The mass-loss results indicated material life, exptrapolated from experimental mass-loss data, in excess of 100 000 hr in all environments except steam and N2H4, where it was greater than or =45000 hr. Generally, on the basis of mass loss, there were no compatibility concerns in any of the environments considered. Optical and scanning electron microscopy were used to determine the effect of propellants on the material surface and to evaluate material stability.
Europa Propulsion Valve Seat Material Testing
NASA Technical Reports Server (NTRS)
Addona, Brad M.
2017-01-01
The Europa mission and spacecraft design presented unique challenges for selection of valve seat materials that met the fluid compatibility requirements, and combined fluid compatibility and high radiation exposure level requirements. The Europa spacecraft pressurization system valves will be exposed to fully saturated propellant vapor for the duration of the mission. The effects of Nitrogen Tetroxide (NTO) and Monomethylhydrazine (MMH) propellant vapors on heritage valve seat materials, such as Vespel SP-1 and Polychlorotrifluoroethylene (PCTFE), were evaluated to determine if an alternate material is required. In liquid system applications, Teflon is the only available compatible valve seat material. Radiation exposure data for Teflon in an air or vacuum environment has been previously documented. Radiation exposure data for Teflon in an oxidizer environment such as NTO, was not available, and it was unknown whether the effects would be similar to those on air-exposed samples. Material testing was conducted by Marshall Space Flight Center (MSFC) and White Sands Test Facility (WSTF) to determine the effects of propellant vapor on heritage seat materials for pressurization valve applications, and the effects of combined radiation and NTO propellant exposure on Teflon. The results indicated that changes in heritage pressurization valve seat materials' properties rendered them unsuitable for the Europa application. The combined radiation and NTO exposure testing of Teflon produced results equivalent to combined radiation and air exposure results.
Chemical Reactivity Test (CRT)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zaka, F.
The Chemical Reactivity Test (CRT) is used to determine the thermal stability of High Explosives (HEs) and chemical compatibility between (HEs) and alien materials. The CRT is one of the small-scale safety tests performed on HE at the High Explosives Applications Facility (HEAF).
NASA Technical Reports Server (NTRS)
DellaCorte, Christopher; Krantz, Timothy L.; Dube, Michael J.
2011-01-01
The photovoltaic solar panels on the International Space Station (ISS) track the Sun through continuous rotating motion enabled by large bearings on the main truss called solar array alpha rotary joints (SARJs). In late 2007, shortly after installation, the starboard SARJ had become hard to turn and had to be shut down after exceeding drive current safety limits. The port SARJ, of the same design, had been working well for over 2 years. An exhaustive failure investigation ensued that included multiple extravehicular activities to collect information and samples for engineering forensics, detailed structural and thermal analyses, and a careful review of the build records. The ultimate root cause was determined to be kinematic design vulnerability coupled with inadequate lubrication, and manufacturing flaws; this was corroborated through ground tests, metallurgical studies, and modeling. A highly successful recovery plan was developed and implemented that included replacing worn and damaged components in orbit and applying space-compatible grease to improve lubrication. Beyond the technical aspects, however, lie several key programmatic lessons learned. These lessons, such as running ground tests to intentional failure to experimentally verify failure modes, are reviewed and discussed so they can be applied to future projects to avoid such problems.
Shin, Yun Kyoung; Cho, Yang Seok; Lien, Mei-Ching; Proctor, Robert W
2007-09-01
It has been argued that the psychological refractory period (PRP) effect is eliminated with two ideomotor compatible tasks when instructions stress fast and simultaneous responding. Three experiments were conducted to test this hypothesis. In all experiments, Task 1 required spatially compatible manual responses (left or right) to the direction of an arrow, and Task 2 required saying the name of the auditory letter A or B. In Experiments 1 and 3, the manual responses were keypresses made with the left and right hands, whereas in Experiment 2 they were left-right toggle-switch movements made with the dominant hand. Instructions that stressed response speed reduced reaction time and increased error rate compared to standard instructions to respond fast and accurately, but did not eliminate the PRP effect on Task 2 reaction time. These results imply that, even when response speed is emphasized, ideomotor compatible tasks do not bypass response selection.
Suspected X-linked facial dysmorphia and growth retardation in related Labrador retriever puppies.
Dierks, C; Hoffmann, H; Heinrich, F; Hellige, M; Hewicker-Trautwein, M; Distl, O
2017-02-01
Seven male Labrador retriever puppies from four different litters were identified with a brachycephalic-like face and skull, associated with low birth weight, severe growth retardation, and reduced abilities to crawl and suckle, which were not compatible with survival. Excessive doming of the cranium, brachygnathia superior and inferior, and an abnormally opened fontanelle were found in all affected puppies by computed tomography and at post-mortem examination. Pedigree analysis supported an X-linked recessive mode of inheritance. Copyright © 2017 Elsevier Ltd. All rights reserved.
Search for lepton-flavor violation in the decay tau- --> l- l+ l-.
Aubert, B; Barate, R; Boutigny, D; Couderc, F; Gaillard, J-M; Hicheur, A; Karyotakis, Y; Lees, J P; Tisserand, V; Zghiche, A; Palano, A; Pompili, A; Chen, J C; Qi, N D; Rong, G; Wang, P; Zhu, Y S; Eigen, G; Ofte, I; Stugu, B; Abrams, G S; Borgland, A W; Breon, A B; Brown, D N; Button-Shafer, J; Cahn, R N; Charles, E; Day, C T; Gill, M S; Gritsan, A V; Groysman, Y; Jacobsen, R G; Kadel, R W; Kadyk, J; Kerth, L T; Kolomensky, Yu G; Kukartsev, G; LeClerc, C; Levi, M E; Lynch, G; Mir, L M; Oddone, P J; Orimoto, T J; Pripstein, M; Roe, N A; Ronan, M T; Shelkov, V G; Telnov, A V; Wenzel, W A; Ford, K; Harrison, T J; Hawkes, C M; Morgan, S E; Watson, A T; Watson, N K; Fritsch, M; Goetzen, K; Held, T; Koch, H; Lewandowski, B; Pelizaeus, M; Steinke, M; Boyd, J T; Chevalier, N; Cottingham, W N; Kelly, M P; Latham, T E; Wilson, F F; Abe, K; Cuhadar-Donszelmann, T; Hearty, C; Mattison, T S; McKenna, J A; Thiessen, D; Kyberd, P; Teodorescu, L; Blinov, V E; Bukin, A D; Druzhinin, V P; Golubev, V B; Ivanchenko, V N; Kravchenko, E A; Onuchin, A P; Serednyakov, S I; Skovpen, Yu I; Solodov, E P; Yushkov, A N; Best, D; Bruinsma, M; Chao, M; Eschrich, I; Kirkby, D; Lankford, A J; Mandelkern, M; Mommsen, R K; Roethel, W; Stoker, D P; Buchanan, C; Hartfiel, B L; Gary, J W; Shen, B C; Wang, K; Del Re, D; Hadavand, H K; Hill, E J; MacFarlane, D B; Paar, H P; Rahatlou, Sh; Sharma, V; Berryhill, J W; Campagnari, C; Dahmes, B; Levy, S L; Long, O; Lu, A; Mazur, M A; Richman, J D; Verkerke, W; Beck, T W; Eisner, A M; Heusch, C A; Lockman, W S; Schalk, T; Schmitz, R E; Schumm, B A; Seiden, A; Spradlin, P; Williams, D C; Wilson, M G; Albert, J; Chen, E; Dubois-Felsmann, G P; Dvoretskii, A; Hitlin, D G; Narsky, I; Piatenko, T; Porter, F C; Ryd, A; Samuel, A; Yang, S; Jayatilleke, S; Mancinelli, G; Meadows, B T; Sokoloff, M D; Abe, T; Blanc, F; Bloom, P; Chen, S; Clark, P J; Ford, W T; Nauenberg, U; Olivas, A; Rankin, P; Smith, J G; Van Hoek, W C; Zhang, L; Harton, J L; Hu, T; Soffer, A; Toki, W H; Wilson, R J; Altenburg, D; Brandt, T; Brose, J; Colberg, T; Dickopp, M; Feltresi, E; Hauke, A; Lacker, H M; Maly, E; Müller-Pfefferkorn, R; Nogowski, R; Otto, S; Schubert, J; Schubert, K R; Schwierz, R; Spaan, B; Bernard, D; Bonneaud, G R; Brochard, F; Grenier, P; Thiebaux, Ch; Vasileiadis, G; Verderi, M; Bard, D J; Khan, A; Lavin, D; Muheim, F; Playfer, S; Andreotti, M; Azzolini, V; Bettoni, D; Bozzi, C; Calabrese, R; Cibinetto, G; Luppi, E; Negrini, M; Sarti, A; Treadwell, E; Baldini-Ferroli, R; Calcaterra, A; De Sangro, R; Finocchiaro, G; Patteri, P; Piccolo, M; Zallo, A; Buzzo, A; Capra, R; Contri, R; Crosetti, G; Lo Vetere, M; Macri, M; Monge, M R; Passaggio, S; Patrignani, C; Robutti, E; Santroni, A; Tosi, S; Bailey, S; Brandenburg, G; Morii, M; Won, E; Dubitzky, R S; Langenegger, U; Bhimji, W; Bowerman, D A; Dauncey, P D; Egede, U; Gaillard, J R; Morton, G W; Nash, J A; Taylor, G P; Grenier, G J; Lee, S-J; Mallik, U; Cochran, J; Crawley, H B; Lamsa, J; Meyer, W T; Prell, S; Rosenberg, E I; Yi, J; Davier, M; Grosdidier, G; Höcker, A; Laplace, S; Le Diberder, F; Lepeltier, V; Lutz, A M; Petersen, T C; Plaszczynski, S; Schune, M H; Tantot, L; Wormser, G; Cheng, C H; Lange, D J; Simani, M C; Wright, D M; Bevan, A J; Coleman, J P; Fry, J R; Gabathuler, E; Gamet, R; Kay, M; Parry, R J; Payne, D J; Sloane, R J; Touramanis, C; Back, J J; Harrison, P F; Mohanty, G B; Brown, C L; Cowan, G; Flack, R L; Flaecher, H U; George, S; Green, M G; Kurup, A; Marker, C E; McMahon, T R; Ricciardi, S; Salvatore, F; Vaitsas, G; Winter, M A; Brown, D; Davis, C L; Allison, J; Barlow, N R; Barlow, R J; Hart, P A; Hodgkinson, M C; Lafferty, G D; Lyon, A J; Williams, J C; Farbin, A; Hulsbergen, W D; Jawahery, A; Kovalskyi, D; Lae, C K; Lillard, V; Roberts, D A; Blaylock, G; Dallapiccola, C; Flood, K T; Hertzbach, S S; Kofler, R; Koptchev, V B; Moore, T B; Saremi, S; Staengle, H; Willocq, S; Cowan, R; Sciolla, G; Taylor, F; Yamamoto, R K; Mangeol, D J J; Patel, P M; Robertson, S H; Lazzaro, A; Palombo, F; Bauer, J M; Cremaldi, L; Eschenburg, V; Godang, R; Kroeger, R; Reidy, J; Sanders, D A; Summers, D J; Zhao, H W; Brunet, S; Côté, D; Taras, P; Nicholson, H; Cartaro, C; Cavallo, N; Fabozzi, F; Gatto, C; Lista, L; Monorchio, D; Paolucci, P; Piccolo, D; Sciacca, C; Baak, M; Raven, G; Wilden, L; Jessop, C P; LoSecco, J M; Gabriel, T A; Allmendinger, T; Brau, B; Gan, K K; Honscheid, K; Hufnagel, D; Kagan, H; Kass, R; Pulliam, T; Ter-Antonyan, R; Wong, Q K; Brau, J; Frey, R; Igonkina, O; Potter, C T; Sinev, N B; Strom, D; Torrence, E; Colecchia, F; Dorigo, A; Galeazzi, F; Margoni, M; Morandin, M; Posocco, M; Rotondo, M; Simonetto, F; Stroili, R; Tiozzo, G; Voci, C; Benayoun, M; Briand, H; Chauveau, J; David, P; de la Vaissière, Ch; Del Buono, L; Hamon, O; John, M J J; Leruste, Ph; Ocariz, J; Pivk, M; Roos, L; T'Jampens, S; Therin, G; Manfredi, P F; Re, V; Behera, P K; Gladney, L; Guo, Q H; Panetta, J; Anulli, F; Biasini, M; Peruzzi, I M; Pioppi, M; Angelini, C; Batignani, G; Bettarini, S; Bondioli, M; Bucci, F; Calderini, G; Carpinelli, M; Del Gamba, V; Forti, F; Giorgi, M A; Lusiani, A; Marchiori, G; Martinez-Vidal, F; Morganti, M; Neri, N; Paoloni, E; Rama, M; Rizzo, G; Sandrelli, F; Walsh, J; Haire, M; Judd, D; Paick, K; Wagoner, D E; Danielson, N; Elmer, P; Lu, C; Miftakov, V; Olsen, J; Smith, A J S; Varnes, E W; Bellini, F; Cavoto, G; Faccini, R; Ferrarotto, F; Ferroni, F; Gaspero, M; Li Gioi, L; Mazzoni, M A; Morganti, S; Pierini, M; Piredda, G; Safai Tehrani, F; Voena, C; Christ, S; Wagner, G; Waldi, R; Adye, T; De Groot, N; Franek, B; Geddes, N I; Gopal, G P; Olaiya, E O; Xella, S M; Aleksan, R; Emery, S; Gaidot, A; Ganzhur, S F; Giraud, P-F; Hamel de Monchenault, G; Kozanecki, W; Langer, M; Legendre, M; London, G W; Mayer, B; Schott, G; Vasseur, G; Yèche, Ch; Zito, M; Purohit, M V; Weidemann, A W; Yumiceva, F X; Aston, D; Bartoldus, R; Berger, N; Boyarski, A M; Buchmueller, O L; Convery, M R; Cristinziani, M; De Nardo, G; Dong, D; Dorfan, J; Dujmic, D; Dunwoodie, W; Elsen, E E; Field, R C; Glanzman, T; Gowdy, S J; Hadig, T; Halyo, V; Hryn'ova, T; Innes, W R; Kelsey, M H; Kim, P; Kocian, M L; Leith, D W G S; Libby, J; Luitz, S; Luth, V; Lynch, H L; Marsiske, H; Messner, R; Muller, D R; O'Grady, C P; Ozcan, V E; Perazzo, A; Perl, M; Petrak, S; Ratcliff, B N; Roodman, A; Salnikov, A A; Schindler, R H; Schwiening, J; Simi, G; Snyder, A; Soha, A; Stelzer, J; Su, D; Sullivan, M K; Va'vra, J; Wagner, S R; Weaver, M; Weinstein, A J R; Wisniewski, W J; Wittgen, M; Wright, D H; Young, C C; Burchat, P R; Edwards, A J; Meyer, T I; Petersen, B A; Roat, C; Ahmed, S; Alam, M S; Ernst, J A; Saeed, M A; Saleem, M; Wappler, F R; Bugg, W; Krishnamurthy, M; Spanier, S M; Eckmann, R; Kim, H; Ritchie, J L; Satpathy, A; Schwitters, R F; Izen, J M; Kitayama, I; Lou, X C; Ye, S; Bianchi, F; Bona, M; Gallo, F; Gamba, D; Borean, C; Bosisio, L; Cossutti, F; Della Ricca, G; Dittongo, S; Grancagnolo, S; Lanceri, L; Poropat, P; Vitale, L; Vuagnin, G; Panvini, R S; Banerjee, Sw; Brown, C M; Fortin, D; Jackson, P D; Kowalewski, R; Roney, J M; Band, H R; Dasu, S; Datta, M; Eichenbaum, A M; Hollar, J J; Johnson, J R; Kutter, P E; Li, H; Liu, R; Di Lodovico, F; Mihalyi, A; Mohapatra, A K; Pan, Y; Prepost, R; Sekula, S J; Tan, P; von Wimmersperg-Toeller, J H; Wu, J; Wu, S L; Yu, Z; Neal, H
2004-03-26
A search for the lepton-flavor-violating decay of the tau into three charged leptons has been performed using 91.5 fb(-1) of data collected at an e(+)e(-)center-of-mass energy around 10.58 GeV with the BABAR detector at the SLAC storage ring PEP-II. In all six decay modes considered, the numbers of events found in data are compatible with the background expectations. Upper limits on the branching fractions are set in the range (1-3)x10(-7) at 90% confidence level.
Low Earth Orbit satellite/terrestrial mobile service compatibility
NASA Technical Reports Server (NTRS)
Sheriff, Ray E.; Gardiner, John G.
1993-01-01
Currently the geostationary type of satellite is the only one used to provide commercial mobile-satellite communication services. Low earth orbit (LEO) satellite systems are now being proposed as a future alternative. By the implementation of LEO satellite systems, predicted at between 5 and 8 years time, mobile space/terrestrial technology will have progressed to the third generation stage of development. This paper considers the system issues that will need to be addressed when developing a dual mode terminal, enabling access to both terrestrial and LEO satellite systems.
Fluid equations in the presence of electron cyclotron current drive
NASA Astrophysics Data System (ADS)
Jenkins, Thomas G.; Kruger, Scott E.
2012-12-01
Two-fluid equations, which include the physics imparted by an externally applied radiofrequency source near electron cyclotron resonance, are derived in their extended magnetohydrodynamic forms using the formalism of Hegna and Callen [Phys. Plasmas 16, 112501 (2009)]. The equations are compatible with the closed fluid/drift-kinetic model developed by Ramos [Phys. Plasmas 17, 082502 (2010); 18, 102506 (2011)] for fusion-relevant regimes with low collisionality and slow dynamics, and they facilitate the development of advanced computational models for electron cyclotron current drive-induced suppression of neoclassical tearing modes.
Fluid equations in the presence of electron cyclotron current drive
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jenkins, Thomas G.; Kruger, Scott E.
Two-fluid equations, which include the physics imparted by an externally applied radiofrequency source near electron cyclotron resonance, are derived in their extended magnetohydrodynamic forms using the formalism of Hegna and Callen [Phys. Plasmas 16, 112501 (2009)]. The equations are compatible with the closed fluid/drift-kinetic model developed by Ramos [Phys. Plasmas 17, 082502 (2010); 18, 102506 (2011)] for fusion-relevant regimes with low collisionality and slow dynamics, and they facilitate the development of advanced computational models for electron cyclotron current drive-induced suppression of neoclassical tearing modes.
Lantos, Paul M; Branda, John A; Boggan, Joel C; Chudgar, Saumil M; Wilson, Elizabeth A; Ruffin, Felicia; Fowler, Vance; Auwaerter, Paul G; Nigrovic, Lise E
2015-11-01
Lyme disease is diagnosed by 2-tiered serologic testing in patients with a compatible clinical illness, but the significance of positive test results in low-prevalence regions has not been investigated. We reviewed the medical records of patients who tested positive for Lyme disease with standardized 2-tiered serologic testing between 2005 and 2010 at a single hospital system in a region with little endemic Lyme disease. Based on clinical findings, we calculated the positive predictive value of Lyme disease serology. Next, we reviewed the outcome of serologic testing in patients with select clinical syndromes compatible with disseminated Lyme disease (arthritis, cranial neuropathy, or meningitis). During the 6-year study period 4723 patients were tested for Lyme disease, but only 76 (1.6%) had positive results by established laboratory criteria. Among 70 seropositive patients whose medical records were available for review, 12 (17%; 95% confidence interval, 9%-28%) were found to have Lyme disease (6 with documented travel to endemic regions). During the same time period, 297 patients with a clinical illness compatible with disseminated Lyme disease underwent 2-tiered serologic testing. Six of them (2%; 95% confidence interval, 0.7%-4.3%) were seropositive, 3 with documented travel and 1 who had an alternative diagnosis that explained the clinical findings. In this low-prevalence cohort, fewer than 20% of positive Lyme disease tests are obtained from patients with clinically likely Lyme disease. Positive Lyme disease test results may have little diagnostic value in this setting. © The Author 2015. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
NASA Astrophysics Data System (ADS)
Prakoso, N. I.; Rochmadi; Purwono, S.
2018-04-01
One of enhanced oil recovery (EOR) methods is using surfactants to reduce the interfacial tension between the injected fluid and the oil in old reservoir. The most important principle in enhanced oil recovery process is the dynamic interaction of surfactants with crude oil. Sodium ligno sulphonate (SLS) is a commercial surfactant and already synthesized from palm solid waste by another researcher. This work aimed to apply SLS as a surfactant for EOR especially in TPN 008 oil from Pertamina Indonesia. In its application as an EOR’s surfactant, SLS shall be passed feasibility test like IFT, thermal stability, compatibility, filtration, molecular weight, density, viscosity and pH tests. The feasibility test is very important for a preliminary test prior to another advanced test. The results demonstrated that 1% SLS solution in formation water (TPN 008) had 0.254 mN/M IFT value and was also great in thermal stability, compatibility, filtration, molecular weight, viscosity and pH test.
Analysis of visual quality improvements provided by known tools for HDR content
NASA Astrophysics Data System (ADS)
Kim, Jaehwan; Alshina, Elena; Lee, JongSeok; Park, Youngo; Choi, Kwang Pyo
2016-09-01
In this paper, the visual quality of different solutions for high dynamic range (HDR) compression using MPEG test contents is analyzed. We also simulate the method for an efficient HDR compression which is based on statistical property of the signal. The method is compliant with HEVC specification and also easily compatible with other alternative methods which might require HEVC specification changes. It was subjectively tested on commercial TVs and compared with alternative solutions for HDR coding. Subjective visual quality tests were performed using SUHD TVs model which is SAMSUNG JS9500 with maximum luminance up to 1000nit in test. The solution that is based on statistical property shows not only improvement of objective performance but improvement of visual quality compared to other HDR solutions, while it is compatible with HEVC specification.
NASA Technical Reports Server (NTRS)
1978-01-01
The progress made on the development and delivery of noncorrosive fluid subsystems is reported. These subsystems are to be compatible with closed-loop solar heating or combined heating and hot water systems. They are also to be compatible with both metallic and non-metallic plumbing systems. At least 100 gallons of each type of fluid recommended by the contractor will be delivered under the contract. The performance testing of a number of fluids is described.
Arcjet system integration development
NASA Technical Reports Server (NTRS)
Zafran, Sidney
1994-01-01
Compatibility between an arcjet propulsion system and a communications satellite was verified by testing a Government-furnished, 1.4 kW hydrazine arcjet system with the FLTSATCOM qualification model satellite in a 9.1-meter (30-foot) diameter thermal-vacuum test chamber. Background pressure was maintained at 10(exp -5) torr during arcjet operation by cryopumping the thruster exhaust with an array of 5 K liquid helium cooled panels. Power for the arcjet system was obtained from the FLTSATCOM battery simulator. Spacecraft telemetry was monitored during each thruster firing period. No changes in telemetry data attributable to arcjet operation were detected in any of the tests. Electromagnetic compatibility data obtained included radiated emission measurements, conducted emission measurements, and cable coupling measurements. Significant noise was observed at lower frequencies. Above 500 MHz, radiated emissions were generally within limits, indicating that communication links at S-band and higher frequencies will not be affected. Other test data taken with a diagnostic array of calorimeters, radiometers, witness plates, and a residual gas analyzer evidenced compatible operation, and added to the data base for arcjet system integration. Two test series were conducted. The first series only included the arcjet and diagnostic array operating at approximately 0.1 torr background pressure. The second series added the qualification model spacecraft, a solar panel, and the helium cryopanels. Tests were conducted at 0.1 torr and 10(exp-5) torr. The arcjet thruster was canted 20 degrees relative to the solar panel axis, typical of the configuration used for stationkeeping thrusters on geosynchronous communications satellites.
Arcjet system integration development
NASA Astrophysics Data System (ADS)
Zafran, Sidney
1994-03-01
Compatibility between an arcjet propulsion system and a communications satellite was verified by testing a Government-furnished, 1.4 kW hydrazine arcjet system with the FLTSATCOM qualification model satellite in a 9.1-meter (30-foot) diameter thermal-vacuum test chamber. Background pressure was maintained at 10(exp -5) torr during arcjet operation by cryopumping the thruster exhaust with an array of 5 K liquid helium cooled panels. Power for the arcjet system was obtained from the FLTSATCOM battery simulator. Spacecraft telemetry was monitored during each thruster firing period. No changes in telemetry data attributable to arcjet operation were detected in any of the tests. Electromagnetic compatibility data obtained included radiated emission measurements, conducted emission measurements, and cable coupling measurements. Significant noise was observed at lower frequencies. Above 500 MHz, radiated emissions were generally within limits, indicating that communication links at S-band and higher frequencies will not be affected. Other test data taken with a diagnostic array of calorimeters, radiometers, witness plates, and a residual gas analyzer evidenced compatible operation, and added to the data base for arcjet system integration. Two test series were conducted. The first series only included the arcjet and diagnostic array operating at approximately 0.1 torr background pressure. The second series added the qualification model spacecraft, a solar panel, and the helium cryopanels. Tests were conducted at 0.1 torr and 10(exp-5) torr. The arcjet thruster was canted 20 degrees relative to the solar panel axis, typical of the configuration used for stationkeeping thrusters on geosynchronous communications satellites.
Thünken, Timo; Meuthen, Denis; Bakker, Theo C M; Baldauf, Sebastian A
2012-08-07
Mating preferences for genetic compatibility strictly depend on the interplay of the genotypes of potential partners and are therein fundamentally different from directional preferences for ornamental secondary sexual traits. Thus, the most compatible partner is on average not the one with most pronounced ornaments and vice versa. Hence, mating preferences may often conflict. Here, we present a solution to this problem while investigating the interplay of mating preferences for relatedness (a compatibility criterion) and large body size (an ornamental or quality trait). In previous experiments, both sexes of Pelvicachromis taeniatus, a cichlid fish with mutual mate choice, showed preferences for kin and large partners when these criteria were tested separately. In the present study, test fish were given a conflicting choice between two potential mating partners differing in relatedness as well as in body size in such a way that preferences for both criteria could not simultaneously be satisfied. We show that a sex-specific trade-off occurs between mating preferences for body size and relatedness. For females, relatedness gained greater importance than body size, whereas the opposite was true for males. We discuss the potential role of the interplay between mating preferences for relatedness and body size for the evolution of inbreeding preference.
Thünken, Timo; Meuthen, Denis; Bakker, Theo C. M.; Baldauf, Sebastian A.
2012-01-01
Mating preferences for genetic compatibility strictly depend on the interplay of the genotypes of potential partners and are therein fundamentally different from directional preferences for ornamental secondary sexual traits. Thus, the most compatible partner is on average not the one with most pronounced ornaments and vice versa. Hence, mating preferences may often conflict. Here, we present a solution to this problem while investigating the interplay of mating preferences for relatedness (a compatibility criterion) and large body size (an ornamental or quality trait). In previous experiments, both sexes of Pelvicachromis taeniatus, a cichlid fish with mutual mate choice, showed preferences for kin and large partners when these criteria were tested separately. In the present study, test fish were given a conflicting choice between two potential mating partners differing in relatedness as well as in body size in such a way that preferences for both criteria could not simultaneously be satisfied. We show that a sex-specific trade-off occurs between mating preferences for body size and relatedness. For females, relatedness gained greater importance than body size, whereas the opposite was true for males. We discuss the potential role of the interplay between mating preferences for relatedness and body size for the evolution of inbreeding preference. PMID:22513859
Vadapalli, Sriharsha Babu; Atluri, Kaleswararao; Putcha, Madhu Sudhan; Kondreddi, Sirisha; Kumar, N. Suman; Tadi, Durga Prasad
2016-01-01
Objectives: This in vitro study was designed to compare polyvinyl-siloxane (PVS) monophase and polyether (PE) monophase materials under dry and moist conditions for properties such as surface detail reproduction, dimensional stability, and gypsum compatibility. Materials and Methods: Surface detail reproduction was evaluated using two criteria. Dimensional stability was evaluated according to American Dental Association (ADA) specification no. 19. Gypsum compatibility was assessed by two criteria. All the samples were evaluated, and the data obtained were analyzed by a two-way analysis of variance (ANOVA) and Pearson's Chi-square tests. Results: When surface detail reproduction was evaluated with modification of ADA specification no. 19, both the groups under the two conditions showed no significant difference statistically. When evaluated macroscopically both the groups showed statistically significant difference. Results for dimensional stability showed that the deviation from standard was significant among the two groups, where Aquasil group showed significantly more deviation compared to Impregum group (P < 0.001). Two conditions also showed significant difference, with moist conditions showing significantly more deviation compared to dry condition (P < 0.001). The results of gypsum compatibility when evaluated with modification of ADA specification no. 19 and by giving grades to the casts for both the groups and under two conditions showed no significant difference statistically. Conclusion: Regarding dimensional stability, both impregum and aquasil performed better in dry condition than in moist; impregum performed better than aquasil in both the conditions. When tested for surface detail reproduction according to ADA specification, under dry and moist conditions both of them performed almost equally. When tested according to macroscopic evaluation, impregum and aquasil performed significantly better in dry condition compared to moist condition. In dry condition, both the materials performed almost equally. In moist condition, aquasil performed significantly better than impregum. Regarding gypsum compatibility according to ADA specification, in dry condition both the materials performed almost equally, and in moist condition aquasil performed better than impregum. When tested by macroscopic evaluation, impregum performed better than aquasil in both the conditions. PMID:27583217
Vadapalli, Sriharsha Babu; Atluri, Kaleswararao; Putcha, Madhu Sudhan; Kondreddi, Sirisha; Kumar, N Suman; Tadi, Durga Prasad
2016-01-01
This in vitro study was designed to compare polyvinyl-siloxane (PVS) monophase and polyether (PE) monophase materials under dry and moist conditions for properties such as surface detail reproduction, dimensional stability, and gypsum compatibility. Surface detail reproduction was evaluated using two criteria. Dimensional stability was evaluated according to American Dental Association (ADA) specification no. 19. Gypsum compatibility was assessed by two criteria. All the samples were evaluated, and the data obtained were analyzed by a two-way analysis of variance (ANOVA) and Pearson's Chi-square tests. When surface detail reproduction was evaluated with modification of ADA specification no. 19, both the groups under the two conditions showed no significant difference statistically. When evaluated macroscopically both the groups showed statistically significant difference. Results for dimensional stability showed that the deviation from standard was significant among the two groups, where Aquasil group showed significantly more deviation compared to Impregum group (P < 0.001). Two conditions also showed significant difference, with moist conditions showing significantly more deviation compared to dry condition (P < 0.001). The results of gypsum compatibility when evaluated with modification of ADA specification no. 19 and by giving grades to the casts for both the groups and under two conditions showed no significant difference statistically. Regarding dimensional stability, both impregum and aquasil performed better in dry condition than in moist; impregum performed better than aquasil in both the conditions. When tested for surface detail reproduction according to ADA specification, under dry and moist conditions both of them performed almost equally. When tested according to macroscopic evaluation, impregum and aquasil performed significantly better in dry condition compared to moist condition. In dry condition, both the materials performed almost equally. In moist condition, aquasil performed significantly better than impregum. Regarding gypsum compatibility according to ADA specification, in dry condition both the materials performed almost equally, and in moist condition aquasil performed better than impregum. When tested by macroscopic evaluation, impregum performed better than aquasil in both the conditions.
Evaluation of an MR-compatible blood sampler for PET
NASA Astrophysics Data System (ADS)
Breuer, J.; Grazioso, R.; Zhang, N.; Schmand, M.; Wienhard, K.
2010-10-01
The integration of magnetic resonance imaging (MRI) and positron emission tomography (PET) is an upcoming hybrid imaging technique. Prototype scanners for pre-clinical and clinical research have been built and tested. However, the potential of the PET part can be better exploited if the arterial input function (AIF) of the administered tracer is known. This work presents a dedicated MR-compatible blood sampling system for precise measurement of the AIF in an MR-PET study. The device basically consists of an LSO/APD-detector assembly which performs a coincidence measurement of the annihilation photons resulting from positron decays. During the measurement, arterial blood is drawn continuously from an artery and lead through the detector unit. Besides successful tests of the MR compatibility and the detector performance, measurements of the AIF of rats have been carried out. The results show that the developed blood sampling system is a practical and reliable tool for measuring the AIF in MR-PET studies.
Whispering-Gallery-Mode Tunable Narrow-Band-Pass Filter
NASA Technical Reports Server (NTRS)
Savchenkov, Anatoliy; Iltchenko, Vladimir; Matsko, Andrey; Maleki, Lute
2004-01-01
An experimental tunable, narrow-band-pass electro-optical filter is based on a whispering-gallery resonator. This device is a prototype of tunable filters needed for the further development of reconfigurable networking wavelength-division multiplexers and communication systems that utilize radio-frequency (more specifically, microwave) subcarrier signals on optical carrier signals. The characteristics of whispering-gallery resonators that make them attractive for such applications include high tuning speed, compactness, wide tuning range, low power consumption, and compatibility with single-mode optical fibers. In addition, relative to Fabry-Perot resonators, these devices offer advantages of greater robustness and lower cost. As described in several prior NASA Tech Briefs articles, a whispering-gallery resonator is a spheroidal, disk-like, or toroidal body made of a highly transparent material. It is so named because it is designed to exploit whispering-gallery electromagnetic modes, which are waveguide modes that propagate circumferentially and are concentrated in a narrow toroidal region centered on the equatorial plane and located near the outermost edge. The experimental whispering-gallery tunable filter (see figure) is made from a disk of Z-cut LiNbO3 of 4.8-mm diameter and 0.17-mm thickness. The perimeter of the disk is rounded to a radius of curvature of 100 m. Metal coats on the flat faces of the disk serve as electrodes for exploiting the electro-optical effect in LiNbO3 for tuning. There is no metal coat on the rounded perimeter region, where the whispering-gallery modes propagate. Light is coupled from an input optical fiber into the whispering-gallery modes by means of a diamond prism. Another diamond prism is used to couple light from the whispering-gallery modes to an output optical fiber. This device is designed and operated to exploit transverse magnetic (TM) whispering- gallery modes, rather than transverse electric (TE) modes because the resonance quality factors (Q values) of the TM modes are higher. If Q values were not of major concern, it would be better to use the TE modes because the electro-optical shifts of the TE modes are 3 times those of the TM modes.
ISDN at NASA Lewis Research Center
NASA Technical Reports Server (NTRS)
Bakes, Catherine Murphy; Goldberg, Fredric; Eubanks, Steven W.
1992-01-01
An expository investigation of the potential impact of the Integrated Services Digital Network (ISDN) at NASA Lewis Research Center is described. To properly frame the subject, the paper contains a detailed survey of the components of Narrowband ISDN. The principles and objectives are presented as decreed by the Consultative Committee for International Telephone and Telegraph (CCITT). The various channel types are delineated and their associated service combinations are described. The subscriber-access network functions are explained pictorially via the ISDN reference configuration. A section on switching techniques is presented to enable the reader to understand the emergence of the concept of fast packet switching. This new technology is designed to operate over the high bandwidth, low error rate transmission media that characterizes the LeRC environment. A brief introduction to the next generation of networks is covered with sections on Broadband ISDM (B-ISDN), Asynchronous Transfer Mode (ATM), and Synchronous Optical Networks (SONET). Applications at LeRC are presented, first in terms of targets of opportunity, then in light of compatibility constraints. In-place pilot projects and testing are described that demonstrate actual usage at LeRC.
Set-up of an XAFS beamline for measurements between 2.4-8 keV at DORIS III
DOE Office of Scientific and Technical Information (OSTI.GOV)
Welter, Edmund
2010-06-23
In this paper results from the commissioning phase and from first user experiments of a new EXAFS beamline at the DORIS III storage ring are presented. The bending magnet EXAFS beamline A1 underwent a complete rebuild and now covers the energy range 2.4-8 keV. A Ni-coated toroidal mirror, placed in a 2:1 focusing position and a plane mirror with one Ni coated stripe and one uncoated (SiO{sub 2}) stripe are used for effective higher harmonics suppression and focusing. The UHV-compatible fixed-exit Double Crystal Monochromator (DCM) is equipped with two Si(111) crystal pairs. The second crystal of one of the twomore » crystal pairs is tilted by 90 deg. around the surface normal to shift the position of glitches. It allows Bragg angles between 5 deg. and 55.5 deg. and continuous scans in quick-EXAFS mode. Test measurements during the commissioning phase proved the excellent performance of the monochromator and a high quality of the XAFS spectra over the entire working range.« less
Development of Implantable Wireless Sensor Nodes for Animal Husbandry and MedTech Innovation
Lu, Jian; Zhang, Lan; Zhang, Dapeng; Matsumoto, Sohei; Hiroshima, Hiroshi; Maeda, Ryutaro; Sato, Mizuho; Toyoda, Atsushi; Gotoh, Takafumi; Ohkohchi, Nobuhiro
2018-01-01
In this paper, we report the development, evaluation, and application of ultra-small low-power wireless sensor nodes for advancing animal husbandry, as well as for innovation of medical technologies. A radio frequency identification (RFID) chip with hybrid interface and neglectable power consumption was introduced to enable switching of ON/OFF and measurement mode after implantation. A wireless power transmission system with a maximum efficiency of 70% and an access distance of up to 5 cm was developed to allow the sensor node to survive for a duration of several weeks from a few minutes’ remote charge. The results of field tests using laboratory mice and a cow indicated the high accuracy of the collected biological data and bio-compatibility of the package. As a result of extensive application of the above technologies, a fully solid wireless pH sensor and a surgical navigation system using artificial magnetic field and a 3D MEMS magnetic sensor are introduced in this paper, and the preliminary experimental results are presented and discussed. PMID:29587448
NASA Technical Reports Server (NTRS)
Sharp, G. R.; Gedeon, L.; Oglebay, J. C.; Shaker, F. S.; Siegert, C. E.
1978-01-01
A prototype electric power management and thruster control system for a 30 cm ion thruster is described. The system meets all of the requirements necessary to operate a thruster in a fully automatic mode. Power input to the system can vary over a full two to one dynamic range (200 to 400 V) for the solar array or other power source. The power management and control system is designed to protect the thruster, the flight system and itself from arcs and is fully compatible with standard spacecraft electronics. The system is easily integrated into flight systems which can operate over a thermal environment ranging from 0.3 to 5 AU. The complete power management and control system measures 45.7 cm (18 in.) x 15.2 cm (6 in.) x 114.8 cm (45.2 in.) and weighs 36.2 kg (79.7 lb). At full power the overall efficiency of the system is estimated to be 87.4 percent. Three systems are currently being built and a full schedule of environmental and electrical testing is planned.
An accurate behavioral model for single-photon avalanche diode statistical performance simulation
NASA Astrophysics Data System (ADS)
Xu, Yue; Zhao, Tingchen; Li, Ding
2018-01-01
An accurate behavioral model is presented to simulate important statistical performance of single-photon avalanche diodes (SPADs), such as dark count and after-pulsing noise. The derived simulation model takes into account all important generation mechanisms of the two kinds of noise. For the first time, thermal agitation, trap-assisted tunneling and band-to-band tunneling mechanisms are simultaneously incorporated in the simulation model to evaluate dark count behavior of SPADs fabricated in deep sub-micron CMOS technology. Meanwhile, a complete carrier trapping and de-trapping process is considered in afterpulsing model and a simple analytical expression is derived to estimate after-pulsing probability. In particular, the key model parameters of avalanche triggering probability and electric field dependence of excess bias voltage are extracted from Geiger-mode TCAD simulation and this behavioral simulation model doesn't include any empirical parameters. The developed SPAD model is implemented in Verilog-A behavioral hardware description language and successfully operated on commercial Cadence Spectre simulator, showing good universality and compatibility. The model simulation results are in a good accordance with the test data, validating high simulation accuracy.
Sensitivity of technetium-99m-pyrophosphate scintigraphy in diagnosing cardiac amyloidosis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Falk, R.H.; Lee, V.W.; Rubinow, A.
1983-03-01
To determine the value of technetium-99m-pyrophosphate myocardial scintigraphy in the diagnosis of amyloid heart disease this procedure was prospectively performed in 20 consecutive patients with biopsy-proven primary amyloidosis. Eleven patients had echocardiographic abnormalities compatible with amyloid cardiomyopathy, 9 of whom had congestive heart failure. Diffuse myocardial pyrophosphate uptake was of equal or greater intensity than that of the ribs in 9 of the 11 patients with echocardiograms suggestive of amyloidosis, but in only 2 of the 9 with normal echocardiograms, despite abnormal electrocardiograms (p less than 0.01). Increased wall thickness measured by M-mode echocardiography correlated with myocardial pyrophosphate uptake (rmore » . 0.68, p less than 0.01). None of 10 control patients with nonamyloid, nonischemic heart disease had a strongly positive myocardial pyrophosphate uptake. Thus, myocardial technetium-99m-pyrophosphate scanning is a sensitive and specific test for the diagnosis of cardiac amyloidosis in patients with congestive heart failure of obscure origin. It does not appear to be of value for the early detection of cardiac involvement in patients with known primary amyloidosis without echocardiographic abnormalities.« less
Graphical workstation capability for reliability modeling
NASA Technical Reports Server (NTRS)
Bavuso, Salvatore J.; Koppen, Sandra V.; Haley, Pamela J.
1992-01-01
In addition to computational capabilities, software tools for estimating the reliability of fault-tolerant digital computer systems must also provide a means of interfacing with the user. Described here is the new graphical interface capability of the hybrid automated reliability predictor (HARP), a software package that implements advanced reliability modeling techniques. The graphics oriented (GO) module provides the user with a graphical language for modeling system failure modes through the selection of various fault-tree gates, including sequence-dependency gates, or by a Markov chain. By using this graphical input language, a fault tree becomes a convenient notation for describing a system. In accounting for any sequence dependencies, HARP converts the fault-tree notation to a complex stochastic process that is reduced to a Markov chain, which it can then solve for system reliability. The graphics capability is available for use on an IBM-compatible PC, a Sun, and a VAX workstation. The GO module is written in the C programming language and uses the graphical kernal system (GKS) standard for graphics implementation. The PC, VAX, and Sun versions of the HARP GO module are currently in beta-testing stages.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tichenor, Daniel A.; Ray-Chaudhuri, Avijit K.; Replogle, William C.
The Engineering Test Stand (ETS) is a developmental lithography tool designed to demonstrate full-field EUV imaging and provide data for commercial-tool development. In the first phase of integration, currently in progress, the ETS is configured using a developmental projection system, while fabrication of an improved projection system proceeds in parallel. The optics in the second projection system have been fabricated to tighter specifications for improved resolution and reduced flare. The projection system is a 4-mirror, 4x-reduction, ring-field design having a numeral aperture of 0.1, which supports 70 nm resolution at a k{sub 1} of 0.52. The illuminator produces 13.4 nmmore » radiation from a laser-produced plasma, directs the radiation onto an arc-shaped field of view, and provides an effective fill factor at the pupil plane of 0.7. The ETS is designed for full-field images in step-and-scan mode using vacuum-compatible, magnetically levitated, scanning stages. This paper describes system performance observed during the first phase of integration, including static resist images of 100 nm isolated and dense features.« less
Future Directions for Space Transportation and Propulsion at NASA
NASA Technical Reports Server (NTRS)
Sackheim, Robert L.
2005-01-01
Contents include the following: Oxygen Compatible Materials. Manufacturing Technology Demonstrations. Turbopump Inducer Waterflow Test. Turbine Damping "Whirligig" Test. Single Element Preburner and Main Injector Test. 40K Multi-Element Preburner and MI. Full-Scale Battleship Preburner. Prototype Preburner Test Article. Full-Scale Prototype TCA. Turbopump Hot-Fire Test Article. Prototype Engine. Validated Analytical Models.
NASA Astrophysics Data System (ADS)
Raylman, Raymond R.; Majewski, Stan; Velan, S. Sendhil; Lemieux, Susan; Kross, Brian; Popov, Vladimir; Smith, Mark F.; Weisenberger, Andrew G.
2007-06-01
Multi-modality imaging (such as PET-CT) is rapidly becoming a valuable tool in the diagnosis of disease and in the development of new drugs. Functional images produced with PET, fused with anatomical images created by MRI, allow the correlation of form with function. Perhaps more exciting than the combination of anatomical MRI with PET, is the melding of PET with MR spectroscopy (MRS). Thus, two aspects of physiology could be combined in novel ways to produce new insights into the physiology of normal and pathological processes. Our team is developing a system to acquire MRI images and MRS spectra, and PET images contemporaneously. The prototype MR-compatible PET system consists of two opposed detector heads (appropriate in size for small animal imaging), operating in coincidence mode with an active field-of-view of ˜14 cm in diameter. Each detector consists of an array of LSO detector elements coupled through a 2-m long fiber optic light guide to a single position-sensitive photomultiplier tube. The use of light guides allows these magnetic field-sensitive elements of the PET imager to be positioned outside the strong magnetic field of our 3T MRI scanner. The PET scanner imager was integrated with a 12-cm diameter, 12-leg custom, birdcage coil. Simultaneous MRS spectra and PET images were successfully acquired from a multi-modality phantom consisting of a sphere filled with 17 brain relevant substances and a positron-emitting radionuclide. There were no significant changes in MRI or PET scanner performance when both were present in the MRI magnet bore. This successful initial test demonstrates the potential for using such a multi-modality to obtain complementary MRS and PET data.
Microelectromechanical systems (MEMS) sensors based on lead zirconate titanate (PZT) films
NASA Astrophysics Data System (ADS)
Wang, Li-Peng
2001-12-01
In this thesis, modeling, fabrication and testing of microelectromechanical systems (MEMS) accelerometers based on piezoelectric lead zirconate titanate (PZT) films are investigated. Three different types of structures, cantilever beam, trampoline, and annular diaphragm, are studied. It demonstrates the high-performance, miniaturate, mass-production-compatible, and potentially circuitry-integratable piezoelectric-type PZT MEMS devices. Theoretical models of the cantilever-beam and trampoline accelerometers are derived via structural dynamics and the constitutive equations of piezoelectricity. The time-dependent transverse vibration equations, mode shapes, resonant frequencies, and sensitivities of the accelerometers are calculated through the models. Optimization of the silicon and PZT thickness is achieved with considering the effects of the structural dynamics, the material properties, and manufacturability for different accelerometer specifications. This work is the first demonstration of the fabrication of bulk-micromachined accelerometers combining a deep-trench reactive ion etching (DRIE) release strategy and thick piezoelectric PZT films deposited using a sol-gel method. Processing challenges which are overcome included materials compatibility, metallization, processing of thick layers, double-side processing, deep-trench silicon etching, post-etch cleaning and process integration. In addition, the processed PZT films are characterized by dielectric, ferroelectric (polarization electric-field hysteresis), and piezoelectric measurements and no adverse effects are found. Dynamic frequency response and impedance resonance measurements are performed to ascertain the performance of the MEMS accelerometers. The results show high sensitivities and broad frequency ranges of the piezoelectric-type PZT MEMS accelerometers; the sensitivities range from 0.1 to 7.6 pC/g for resonant frequencies ranging from 44.3 kHz to 3.7 kHz. The sensitivities were compared to theoretical values and a reasonable agreement (˜36% difference) is obtained.
Propellant material compatibility program and results
NASA Technical Reports Server (NTRS)
Toth, L. R.; Cannon, W. A.; Coulbert, C. D.; Long, H. R.
1976-01-01
The effects of long-term (up to 10 years) contact of inert materials with earth-storable propellants were studied for the purpose of designing chemical propulsion system components that can be used for current as well as future planetary spacecraft. The primary experimental work, and results to date are reported. Investigations include the following propellants: hydrazine, hydrazine-hydrazine nitrate blends, monomethyl-hydrazine, and nitrogen tetroxide. Materials include: aluminum alloys, corrosion-resistant steels, and titanium alloys. More than 700 test specimen capsules were placed in long-term storage testing at 43 C in the special material compatibility facility. Material ratings relative to the 10-year requirement have been assigned.
NASA Technical Reports Server (NTRS)
Wingard, C. D.
2018-01-01
The Universal Waste Management System (UWMS) is an improved Waste Collection System for astronauts living and working in low Earth orbit spacecraft. Polymeric materials used in water recovery on International Space Station are regularly exposed to phosphoric acid-treated 'pretreated' urine. Polymeric materials used in UWMS are not only exposed to pretreated urine, but also to concentrated phosphoric acid with oxidizer before dilution known as 'pure pretreat.' Samples of five different polymeric materials immersed in pure pretreat for 1 year were tested for liquid compatibility by measuring changes in storage modulus with a dynamic mechanical analyzer.
NASA Technical Reports Server (NTRS)
Estes, Robert H.; Moore, N. R.
2007-01-01
NASA's Global Precipitation Measurement (GPM) mission is an ongoing Goddard Space Flight Center (GSFC) project whose basic objective is to improve global precipitation measurements. It has been decided that the GPM spacecraft is to be a "design for demise" spacecraft. This requirement resulted in the need for a propellant tank that would also demise or ablate to an appropriate degree upon re-entry. This paper will describe GSFC-performed spacecraft and tankage demise analyses, vendor conceptual design studies, and vendor performed hydrazine compatibility and wettability tests performed on 6061 and 2219 aluminum alloys.
Electromagnetic compatibility of PLC adapters for in-home/domestic networks
NASA Astrophysics Data System (ADS)
Potisk, Lukas; Hallon, Jozef; Orgon, Milos; Fujdiak, Radek
2018-01-01
The use of programable logic controllers (PLC) technology in electrical networks 230 V causes electromagnetic radiation that interferes with other electrical equipment connected to the network [1-4]. Therefore, this article describes the issues of electromagnetic compatibility (EMC) of new PLC adapters used in IP broadband services in a multi-user environment. The measurements of disturbing electromagnetic field originated in PLC adapters were made in a certified laboratory EMC (laboratory of electromagnetic compatibility) in the Institute of Electrical Engineering at Faculty of Electrical Engineering and Information Technology of the Slovak University of Technology in Bratislava. The measured spectra of the radiated electromagnetic field will be compared with the results obtained when testing older PLC modems [5].
Joiner, Logan C; Tynes, Clay; Arnold, John; Miller, Rachel R; Gorman, Greg
2018-04-01
Purpose: The purpose of this study was to determine the physical compatibility of micafungin with commonly used concentrations of sodium bicarbonate hydration fluids administered via a Y-site connected to a central venous catheter (Y-site/CVC). Methods: Micafungin sodium (evaluated concentration of 1.5 mg/mL) was combined in a 3:1 (vehicle:drug) ratio with the following commonly used hydration vehicles: 40 mEq/L sodium bicarbonate in 5% dextrose in water with ¼ normal saline (40SB-D5W-1/4NS), 75 mEq/L sodium bicarbonate in D5W (75SB-D5W), and 154 mEq/L sodium bicarbonate in D5W (154SB-D5W). A 3:1 ratio was used based on the flow rates (typically 125 mL/m 2 /h for bicarbonate-containing vehicles and 50 mL/h for micafungin) of the corresponding solutions in a clinical setting. Visual observations recorded to determine physical compatibility included visual inspection against different backgrounds (unaided, black, and white). Other physical observations were as follows: odor, evolution of gas, pH, and turbidity immediately recorded after mixing and at specified time points up to 2 hours. Evaluations at each time point were compared against baseline observation values at Time 0. Results: All combinations tested were found to be compatible up to 2 hours. Time points beyond 2 hours cannot be safely verified as compatible. Conclusion: Micafungin may be administered safely using a Y-site/CVC delivery system with all the vehicles tested in this study.
Image quality associated with the use of an MR-compatible incubator in neonatal neuroimaging.
O'Regan, K; Filan, P; Pandit, N; Maher, M; Fanning, N
2012-04-01
MRI in the neonate poses significant challenges associated with patient transport and monitoring, and the potential for diminished image quality owing to patient motion. The objective of this study was to evaluate the usefulness of a dedicated MR-compatible incubator with integrated radiofrequency coils in improving image quality of MRI studies of the brain acquired in term and preterm neonates using standard MRI equipment. Subjective and objective analyses of image quality of neonatal brain MR examinations were performed before and after the introduction of an MR-compatible incubator. For all studies, the signal-to-noise ratio (SNR) was calculated, image quality was graded (1-3) and each was assessed for image artefact (e.g. motion). Student's t-test and the Mann-Whitney U-test were used to compare mean SNR values. 39 patients were included [mean gestational age 39 weeks (range 30-42 weeks); mean postnatal age 13 days (range 1-56 days); mean weight 3.5 kg (range 1.4-4.5 kg)]. Following the introduction of the MR-compatible incubator, diagnostic quality scans increased from 50 to 89% and motion artefact decreased from 73 to 44% of studies. SNR did not increase initially, but, when using MR sequences and parameters specifically tailored for neonatal brain imaging, SNR increased from 70 to 213 (p=0.001). Use of an MR-compatible incubator in neonatal neuroimaging provides a safe environment for MRI of the neonate and also facilitates patient monitoring and transport. When specifically tailored MR protocols are used, this results in improved image quality.
Modeling of magnetorheological fluid in quasi-static squeeze flow mode
NASA Astrophysics Data System (ADS)
Horak, Wojciech
2018-06-01
This work presents a new nonlinear model to describe MR fluid behavior in the squeeze flow mode. The basis for deriving the model were the principles of continuum mechanics and the theory of tensor transformation. The analyzed case concerned quasi-static squeeze with a constant area, between two parallel plates with non-slip boundary conditions. The developed model takes into account the rheological properties or MR fluids as a viscoplastic material for which yield stress increases due to compression. The model also takes into account the formation of normal force in the MR fluid as a result of the magnetic field impact. Moreover, a new parameter has been introduced which characterizes the behavior of MR fluid subjected to compression. The proposed model has been experimentally validated and the obtained results suggest that the assumptions made in the model development are reasonable, as good model compatibility with the experiments was obtained.
Kohigashi, Tsuyoshi; Otsuka, Yoichi; Shimazu, Ryo; Matsumoto, Takuya; Iwata, Futoshi; Kawasaki, Hideya; Arakawa, Ryuichi
2016-01-01
Mass spectrometry imaging (MSI) with ambient sampling and ionization can rapidly and easily capture the distribution of chemical components in a solid sample. Because the spatial resolution of MSI is limited by the size of the sampling area, reducing sampling size is an important goal for high resolution MSI. Here, we report the first use of a nanopipette for sampling and ionization by tapping-mode scanning probe electrospray ionization (t-SPESI). The spot size of the sampling area of a dye molecular film on a glass substrate was decreased to 6 μm on average by using a nanopipette. On the other hand, ionization efficiency increased with decreasing solvent flow rate. Our results indicate the compatibility between a reduced sampling area and the ionization efficiency using a nanopipette. MSI of micropatterns of ink on a glass and a polymer substrate were also demonstrated. PMID:28101441
Universality of Generalized Bunching and Efficient Assessment of Boson Sampling.
Shchesnovich, V S
2016-03-25
It is found that identical bosons (fermions) show a generalized bunching (antibunching) property in linear networks: the absolute maximum (minimum) of the probability that all N input particles are detected in a subset of K output modes of any nontrivial linear M-mode network is attained only by completely indistinguishable bosons (fermions). For fermions K is arbitrary; for bosons it is either (i) arbitrary for only classically correlated bosons or (ii) satisfies K≥N (or K=1) for arbitrary input states of N particles. The generalized bunching allows us to certify in a polynomial in N number of runs that a physical device realizing boson sampling with an arbitrary network operates in the regime of full quantum coherence compatible only with completely indistinguishable bosons. The protocol needs only polynomial classical computations for the standard boson sampling, whereas an analytic formula is available for the scattershot version.
Hereditary esophageal dysfunction in the Miniature Schnauzer dog.
Cox, V S; Wallace, L J; Anderson, V E; Rushmer, R A
1980-03-01
Miniature Schnauzers maintained in a colony for 9 years were used to study the inheritance of esophageal dysfunction (canine achalasia, megaesophagus). All dogs were evaluated radiographically, using a barium swallow contrast technique which clearly distinguished normal and affected pups. At 4 to 6 months of age, all affected dogs had recovered clinically except one, and radiographic evidence of dysfunction was markedly diminished. None of the affected dogs required a special feeding regimen. Analysis of breeding pairs revealed a ratio of 9 affected/11 normal dogs when an affected male was mated with a normal female, and a 13/3 ratio was observed when two affected dogs were mated. These ratios were compatible with a simple autosomal dominant or a 60% penetrance autosomal-recessive mode of inheritance. Outbreeding to an affected Miniature Schnauzer/Poodle crossbred dog resulted in only two of 30 affected pups, indicating a polygenic mode of inheritance in outbred populations.
Modeling of Slot Waveguide Sensors Based on Polymeric Materials
Bettotti, Paolo; Pitanti, Alessandro; Rigo, Eveline; De Leonardis, Francesco; Passaro, Vittorio M. N.; Pavesi, Lorenzo
2011-01-01
Slot waveguides are very promising for optical sensing applications because of their peculiar spatial mode profile. In this paper we have carried out a detailed analysis of mode confinement properties in slot waveguides realized in very low refractive index materials. We show that the sensitivity of a slot waveguide is not directly related to the refractive index contrast of high and low materials forming the waveguide. Thus, a careful design of the structures allows the realization of high sensitivity devices even in very low refractive index materials (e.g., polymers) to be achieved. Advantages of low index dielectrics in terms of cost, functionalization and ease of fabrication are discussed while keeping both CMOS compatibility and integrable design schemes. Finally, applications of low index slot waveguides as substitute of bulky fiber capillary sensors or in ring resonator architectures are addressed. Theoretical results of this work are relevant to well established polymer technologies. PMID:22164020
Ideal Magnetic Dipole Scattering
NASA Astrophysics Data System (ADS)
Feng, Tianhua; Xu, Yi; Zhang, Wei; Miroshnichenko, Andrey E.
2017-04-01
We introduce the concept of tunable ideal magnetic dipole scattering, where a nonmagnetic nanoparticle scatters light as a pure magnetic dipole. High refractive index subwavelength nanoparticles usually support both electric and magnetic dipole responses. Thus, to achieve ideal magnetic dipole scattering one has to suppress the electric dipole response. Such a possibility was recently demonstrated for the so-called anapole mode, which is associated with zero electric dipole scattering. By spectrally overlapping the magnetic dipole resonance with the anapole mode, we achieve ideal magnetic dipole scattering in the far field with tunable strong scattering resonances in the near infrared spectrum. We demonstrate that such a condition can be realized at least for two subwavelength geometries. One of them is a core-shell nanosphere consisting of a Au core and silicon shell. It can be also achieved in other geometries, including nanodisks, which are compatible with current nanofabrication technology.
An estimation of global solar p-mode frequencies from IRIS network data: 1989-1996
NASA Astrophysics Data System (ADS)
Serebryanskiy, A.; Ehgamberdiev, Sh.; Kholikov, Sh.; Fossat, E.; Gelly, B.; Schmider, F. X.; Grec, G.; Cacciani, A.; Palle, P. L.; Lazrek, M.; Hoeksema, J. T.
2001-06-01
The IRIS network has accumulated full disk helioseismological data since July 1989, i.e. a complete 11-year solar cycle. Since the last paper publishing a frequency list [A&A 317 (1997) L71], not only has the network acquired new data, but has also developed new co-operative programs with compatible instruments [Abstr. SOHO 6/GONG 98 Workshop (1998) 51], so that merging IRIS files with these co-operative program data sets has made possible the improvement of the overall duty cycle. This paper presents new estimations of low degree p-mode frequencies obtained from this IRIS++ data bank covering the period 1989-1996, as well as the variation of their main parameters along the total range of magnetic activity, from before the last maximum to the very minimum. A preliminary estimation of the peak profile asymmetries is also included.
Asteroid models from photometry and complementary data sources
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kaasalainen, Mikko
I discuss inversion methods for asteroid shape and spin reconstruction with photometry (lightcurves) and complementary data sources such as adaptive optics or other images, occultation timings, interferometry, and range-Doppler radar data. These are essentially different sampling modes (generalized projections) of plane-of-sky images. An important concept in this approach is the optimal weighting of the various data modes. The maximum compatibility estimate, a multi-modal generalization of the maximum likelihood estimate, can be used for this purpose. I discuss the fundamental properties of lightcurve inversion by examining the two-dimensional case that, though not usable in our three-dimensional world, is simple to analyze,more » and it shares essentially the same uniqueness and stability properties as the 3-D case. After this, I review the main aspects of 3-D shape representations, lightcurve inversion, and the inclusion of complementary data.« less
Peeters, Bart; Geerts, Inge; Van Mullem, Mia; Micalessi, Isabel; Saegeman, Veroniek; Moerman, Jan
2016-05-01
Many hospitals opt for early postnatal discharge of newborns with a potential risk of readmission for neonatal hyperbilirubinemia. Assays/algorithms with the possibility to improve prediction of significant neonatal hyperbilirubinemia are needed to optimize screening protocols and safe discharge of neonates. This study investigated the predictive value of umbilical cord blood (UCB) testing for significant hyperbilirubinemia. Neonatal UCB bilirubin, UCB direct antiglobulin test (DAT), and blood group were determined, as well as the maternal blood group and the red blood cell antibody status. Moreover, in newborns with clinically apparent jaundice after visual assessment, plasma total bilirubin (TB) was measured. Clinical factors positively associated with UCB bilirubin were ABO incompatibility, positive DAT, presence of maternal red cell antibodies, alarming visual assessment and significant hyperbilirubinemia in the first 6 days of life. UCB bilirubin performed clinically well with an area under the receiver-operating characteristic curve (AUC) of 0.82 (95 % CI 0.80-0.84). The combined UCB bilirubin, DAT, and blood group analysis outperformed results of these parameters considered separately to detect significant hyperbilirubinemia and correlated exponentially with hyperbilirubinemia post-test probability. Post-test probabilities for neonatal hyperbilirubinemia can be calculated using exponential functions defined by UCB bilirubin, DAT, and ABO compatibility results. • The diagnostic value of the triad umbilical cord blood bilirubin measurement, direct antiglobulin testing and blood group analysis for neonatal hyperbilirubinemia remains unclear in literature. • Currently no guideline recommends screening for hyperbilirubinemia using umbilical cord blood. What is New: • Post-test probability for hyperbilirubinemia correlated exponentially with umbilical cord blood bilirubin in different risk groups defined by direct antiglobulin test and ABO blood group compatibility results. • Exponential functions can be used to calculate hyperbilirubinemia probability.
Soukhanovskii, V. A.; Allen, S. L.; Fenstermacher, M. E.; ...
2016-06-02
Experimental results from the National Spherical Torus Experiment (NSTX), a medium-size spherical tokamak with a compact divertor, and DIII-D, a large conventional aspect ratio tokamak, demonstrate that the snowflake (SF) divertor configuration may provide a promising solution for mitigating divertor heat loads and target plate erosion compatible with core H-mode confinement in future fusion devices, where the standard radiative divertor solution may be inadequate. In NSTX, where the initial high-power SF experiment were performed, the SF divertor was compatible with H-mode confinement, and led to the destabilization of large ELMs. However, a stable partial detachment of the outer strike pointmore » was also achieved where inter-ELM peak heat flux was reduced by factors 3-5, and peak ELM heat flux was reduced by up to 80% (cf. standard divertor). The DIII-D studies show the SF divertor enables significant power spreading in attached and radiative divertor conditions. Results include: compatibility with the core and pedestal, peak inter-ELM divertor heat flux reduction due to geometry at lower n e, and ELM energy and divertor peak heat flux reduction, especially prominent in radiative D 2-seeded SF divertor, and nearly complete power detachment and broader radiated power distribution in the radiative D 2-seeded SF divertor at P SOL = 3 - 4 MW. A variety of SF configurations can be supported by the divertor coil set in NSTX Upgrade. Edge transport modeling with the multi-fluid edge transport code UEDGE shows that the radiative SF divertor can successfully reduce peak divertor heat flux for the projected P SOL ≃9 MW case. In conclusion, the radiative SF divertor with carbon impurity provides a wider n e operating window, 50% less argon is needed in the impurity-seeded SF configuration to achieve similar q peak reduction factors (cf. standard divertor).« less
Highly efficient and compatible shampoo for use after hair transplant
Schweiger, Dorothea; Schoelermann, Andrea M; Filbry, Alexander; Hamann, Tina; Moser, Claudia; Rippke, Frank
2015-01-01
Background Sensitive or hyperreactive skin is a common condition defined by prickling, burning, pain, and pruritus. Although this skin problem was initially described on the face, the scalp is often affected. A sensitive scalp can react with irritation to harsh surfactants or other additives which are often present in shampoos. For this reason, we developed a new rinse-off hypertolerant shampoo specifically designed for the hypersensitive and problematic scalp. Methods The shampoo formulation is based on an extremely mild surfactant system and contains bisabolol, an anti-irritant and anti-inflammatory ingredient of chamomile. The shampoo is free of additives such as perfumes, silicones, colorants, parabens, paraffins, and betaine. Since skin can remain in a hyperreactive state after wounding, the status after hair transplantation was chosen as a model system to test the shampoo. Scalp condition and compatibility of each volunteer were analyzed by a plastic surgeon directly after hair transplant and after stitch removal. The plastic surgeons also rated whether they would recommend the further use of the test shampoo. Additionally, volunteers completed a self-assessment questionnaire. Results Following hair transplantation, regular use of the shampoo resulted in a significant reduction in the extent of scabbing and erythema. This was confirmed by dermatological scalp examinations performed by the plastic surgeon as well as in volunteers’ self-assessments. The plastic surgeon highly recommended the further use of the test shampoo after hair transplant to all study participants. Conclusion Application of the test shampoo demonstrated excellent skin compatibility and product efficacy after hair transplant. The test shampoo significantly reduced the extent of scabs and erythema. Therefore, the shampoo is ideally suited for use after hair transplantation and for the treatment of sensitive scalp. The excellent skin compatibility is because of the mild surfactant system, the calming ingredient bisabolol, and the absence of potentially irritating ingredients. PMID:26229498
NASA Technical Reports Server (NTRS)
Greene, Nathanael; Saulsberry, Regor; Yoder, Tommy; Forsyth, Brad; Carillo, Marlene; Thesken, John
2006-01-01
A viewgraph presentation describing stress rupture testing on Composite Overwrapped Pressure Vessels (COPV) is shown. The topics include: 1) Purpose for Testing; 2) NASA WSTF COPV Test Program; 3) NASA WSTF Test Facilities; 4) COPV Impact Study; 5) Fluids Compatibility Testing; 6) Stress Rupture Testing; and 7) COPV Lifting.
The mixed-mode bending method for delamination testing
NASA Technical Reports Server (NTRS)
Reeder, James R.; Crews, John H., Jr.
1989-01-01
A mixed-mode bending (MMB) test procedure is presented which combines double cantilever beam mode-I loading and end-notch flexure mode II loading on a split, unidirectional laminate. The MMB test has been analyzed by FEM and by beam theory in order to ascertain the mode I and mode II components' respective strain energy release rates, G(I) and G(II); these analyses indicate that a wide range of G(I)/G(II) ratios can be generated by varying the applied load's position on the loading lever. The MMB specimen analysis and test procedures are demonstrated for the case of AS4/PEEK unidirectional laminates.
NASA Technical Reports Server (NTRS)
Ott, Melanie; Thomes, W. Joe; Blair, Diana; Chuska, Rick; Switzer, Rob
2010-01-01
The Diamond AVIM optical fiber connector has been used for over a decade in flight environments. AVIM which stands for Aviation Intermediate Maintenance is always referenced as a fiber optic connector type from the DIN (Deutsches Institut fur Normung) family of optical fiber connectors. The newly available Mini AVIM and DMI (Definition Multimedia Interface) connectors also by Diamond provide similar features as the high performance AVIM with the added benefits of being small form factor for board mount and internal box use where long connectors and strain relief can not be accommodated. Transceiver, fiber laser technology and receiver optic technology based on small sized constraints will benefit the most by the reduction in connector form factor. It is for this reason that the Mini AVIM is being evaluated for multimode and single mode optical fiber use in both fiber based and cable based packaging configurations. In a fiber based termination, there are no cable materials to bond to the connector. The only bonding that is conducted is the mounting of the fiber with epoxy to the connector ferrules (which are called DMI ferrules). In a cable configuration, the compatibility of the connector subcomponents along with the upjacketing materials of the cable around the fiber needs to be considered carefully for termination fabrication. Cabled terminations will show greater insertion loss and high probability of failures during thermal cycling testing. This is due to the stressing of the combination of materials that each have different Coefficients of Thermal Expansion (CTE's) and that are bonded together to the connector subcomponents. As the materials flex during thermal excursions, forces are applied to the termination and can make the system fail if the grouping of materials (per their CTE's) are not compatible and this includes cable materials, epoxies, ferrule and connector body components. For this evaluation, multimode 100 micron core step index fiber was used for the fiber terminated condition, and single mode SMF-28 upjacketed with W.L. Gore Flexlite was used for the cabled configuration. For background purposes, a comparison is presented here for information purposes between the high performance AVIM connector features and the Mini AVIM small form factor connectors. Basic connector features are described here.
Summary of Rocketdyne Engine A5 Rocket Based Combined Cycle Testing
NASA Technical Reports Server (NTRS)
Ketchum. A.; Emanuel, Mark; Cramer, John
1998-01-01
Rocketdyne Propulsion and Power (RPP) has completed a highly successful experimental test program of an advanced rocket based combined cycle (RBCC) propulsion system. The test program was conducted as part of the Advanced Reusable Technology program directed by NASA-MSFC to demonstrate technologies for low-cost access to space. Testing was conducted in the new GASL Flight Acceleration Simulation Test (FAST) facility at sea level (Mach 0), Mach 3.0 - 4.0, and vacuum flight conditions. Significant achievements obtained during the test program include 1) demonstration of engine operation in air-augmented rocket mode (AAR), ramjet mode and rocket mode and 2) smooth transition from AAR to ramjet mode operation. Testing in the fourth mode (scramjet) is scheduled for November 1998.
Jovanović, Marko; Peter-Katalinić, Jasna
2016-02-01
Oligosaccharides represent complex class of analytes for mass spectrometric analysis due to the high variety of structural isomers concerning glycosidic linkages and possible branching. A systematic study of the negative ion mode matrix-assisted laser desorption/ionization (MALDI) mass spectrometry of various neutral oligosaccharides under selection of an appropriate matrix, like 2,5-dihydroxyacetophenone (2,5-DHAP) is reported here, without commonly used anion dopant strategies. Nevertheless, we were able to generate relevant in-source decay (ISD) cross-ring fragment ions, typically obtained in the negative ion mode. Data observed indicate that the intrinsic property of the terminal non-reduced aldose is crucial for this behavior. A systematic study of the post source decay (PSD) of molecular, pseudomolecular and ISD cross-ring cleavage precursor ions is reported here. A direct comparison of the positive and negative ion mode MALDI MS1 and PSD behavior of neutral oligosaccharides could also be performed under the use of the same matrix preparation, because 2,5-DHAP is fully compatible with positive ion mode acquisition. We found that PSD spectra of deprotonated neutral oligosaccharides obtained in the negative ion mode are richer, because they contained both glycosidic and cross-ring fragment ions. However, we also found that cross-ring fragment ions are readily produced in the positive ion mode when potassiated precursor ions were selected. In addition, we show evidence that non-anionic dopants and specific instrumental parameters can also significantly influence the ISD fragmentation. Taken together, our results should increase our understanding of oligosaccharide behavior in the negative ion mode as well as increase our knowledge regarding many aspects of in-source MALDI chemistry. Copyright © 2016 John Wiley & Sons, Ltd.
FLiNaK Compatability Studies with Inconel 600 and Silicon Carbide
Yoder, Jr, Graydon L.; Heatherly, Dennis Wayne; Wilson, Dane F.; ...
2016-07-26
A small liquid fluoride salt test apparatus has been constructed and testing conducted to examine the compatibility of SiC, Inconel 600, and a spiral wound gasket material in FLiNaK salt. These tests were conducted to test materials and sealing systems that would be used in a FLiNaK salt test loop. Three months of testing at 700oC was used to assure that these materials and seals would be acceptable operating under expected test loop conditions. The SiC specimens showed little or no change over the test period while the spiral wound gasket material showed no degradation, except for the possibility ofmore » salt seeping into the outermost spirals of the gasket. The Inconel 600 specimens showed regions of voiding which penetrated the specimen surface to about 250 m in depth. Analysis indicated that the salt had leached chrome from the Inconel surface as was expected for this material. Because the test loop will have a limited working lifetime, it was concluded that these materials would be satisfactory for loop construction.« less
NASA Technical Reports Server (NTRS)
Perry, Jimmy L.
1992-01-01
The same kind of standard and controls are established that are currently in use for the procurement of new analog, digital, and IBM/IBM compatible 3480 tape cartridges, and 1 in wide channel video magnetic tapes. The Magnetic Tape Certification Facility (MTCF) maintains a Qualified Products List (QPL) for the procurement of new magnetic media and uses the following specifications for the QPL and Acceptance Tests: (1) NASA TM-79724 is used for the QPL and Acceptance Testing of new analog magnetic tapes; (2) NASA TM-80599 is used for the QPL and Acceptance Testing of new digital magnetic tapes; (3) NASA TM-100702 is used for the QPL and Acceptance Testing of new IBM/IBM compatible 3840 magnetic tape cartridges; and (4) NASA TM-100712 is used for the QPL and Acceptance Testing of new 1 in wide channel video magnetic tapes. This document will be used for the QPL and Acceptance Testing of new Helical Scan 8 mm digital data tape cartridges.
NASA Technical Reports Server (NTRS)
Heard, Walter L., Jr.; Lake, Mark S.; Bush, Harold G.; Jensen, J. Kermit; Phelps, James E.; Wallsom, Richard E.
1992-01-01
This report presents results of tests performed in neutral buoyancy by two pressure-suited test subjects to simulate Extravehicular Activity (EVA) tasks associated with the on-orbit construction and repair of a precision reflector spacecraft. Two complete neutral buoyancy assemblies of the test article (tetrahedral truss with three attached reflector panels) were performed. Truss joint hardware, two different panel attachment hardware concepts, and a panel replacement tool were evaluated. The test subjects found the operation and size of the truss joint hardware to be acceptable. Both panel attachment concepts were found to be EVA compatible, although one concept was judged by the test subjects to be considerably easier to operate. The average time to install a panel from a position within arm's reach of the test subjects was 1 min 14 sec. The panel replacement tool was used successfully to demonstrate the removal and replacement of a damaged reflector panel in 10 min 25 sec.
Luo, Ye; Chamanzar, Maysamreza; Apuzzo, Aniello; Salas-Montiel, Rafael; Nguyen, Kim Ngoc; Blaize, Sylvain; Adibi, Ali
2015-02-11
The enhancement and confinement of electromagnetic radiation to nanometer scale have improved the performances and decreased the dimensions of optical sources and detectors for several applications including spectroscopy, medical applications, and quantum information. Realization of on-chip nanofocusing devices compatible with silicon photonics platform adds a key functionality and provides opportunities for sensing, trapping, on-chip signal processing, and communications. Here, we discuss the design, fabrication, and experimental demonstration of light nanofocusing in a hybrid plasmonic-photonic nanotaper structure. We discuss the physical mechanisms behind the operation of this device, the coupling mechanisms, and how to engineer the energy transfer from a propagating guided mode to a trapped plasmonic mode at the apex of the plasmonic nanotaper with minimal radiation loss. Optical near-field measurements and Fourier modal analysis carried out using a near-field scanning optical microscope (NSOM) show a tight nanofocusing of light in this structure to an extremely small spot of 0.00563(λ/(2n(rmax)))(3) confined in 3D and an exquisite power input conversion of 92%. Our experiments also verify the mode selectivity of the device (low transmission of a TM-like input mode and high transmission of a TE-like input mode). A large field concentration factor (FCF) of about 4.9 is estimated from our NSOM measurement with a radius of curvature of about 20 nm at the apex of the nanotaper. The agreement between our theory and experimental results reveals helpful insights about the operation mechanism of the device, the interplay of the modes, and the gradual power transfer to the nanotaper apex.
Lim, H P; Fong, Y K
2005-01-01
Basidiospores were isolated from the fruiting bodies of Ganoderma infecting oil palms from an estate in Johor and from ornamental palms (including oil palms) from Singapore. The spores were then germinated to obtain homokaryotic mycelia. Based on clamp connection formation in paired hyphal fusions, tester strains were identified from the homokaryons isolated. Compatibility tests were then carried out using these testers to determine the relatedness of the homokaryotic Ganoderma isolates, both from Johor and from Singapore. Results from the compatibility tests showed that Ganoderma from both locations belong to the same species, while the Ganoderma isolates from Singapore share some common alleles. The pathogenicity tests carried out on Chrysalidocarpus lutescens seedlings using inoculum growing on rubber wood blocks showed that dikaryotic mycelia can cause basal stem rot infection.
Assessment of theory of mind in children with communication disorders: role of presentation mode.
van Buijsen, Marit; Hendriks, Angelique; Ketelaars, Mieke; Verhoeven, Ludo
2011-01-01
Children with communication disorders have problems with both language and social interaction. The theory-of-mind hypothesis provides an explanation for these problems, and different tests have been developed to test this hypothesis. However, different modes of presentation are used in these tasks, which make the results difficult to compare. In the present study, the performances of typically developing children, children with specific language impairments, and children with autism spectrum disorders were therefore compared using three theory-of-mind tests (the Charlie test, the Smarties test, and the Sally-and-Anne test) presented in three different manners each (spoken, video, and line drawing modes). The results showed differential outcomes for the three types of tests and a significant interaction between group of children and mode of presentation. For the typically developing children, no differential effects of presentation mode were detected. For the children with SLI, the highest test scores were consistently evidenced in the line-drawing mode. For the children with ASD, test performance depended on the mode of presentation. Just how the children's non-verbal age, verbal age, and short-term memory related to their test scores was also explored for each group of children. The test scores of the SLI group correlated significantly with their short-term memory, those of the ASD group with their verbal age. These findings demonstrate that performance on theory-of-mind tests clearly depend upon mode of test presentation as well as the children's cognitive and linguistic abilities. Copyright © 2011 Elsevier Ltd. All rights reserved.
A reduced order, test verified component mode synthesis approach for system modeling applications
NASA Astrophysics Data System (ADS)
Butland, Adam; Avitabile, Peter
2010-05-01
Component mode synthesis (CMS) is a very common approach used for the generation of large system models. In general, these modeling techniques can be separated into two categories: those utilizing a combination of constraint modes and fixed interface normal modes and those based on a combination of free interface normal modes and residual flexibility terms. The major limitation of the methods utilizing constraint modes and fixed interface normal modes is the inability to easily obtain the required information from testing; the result of this limitation is that constraint mode-based techniques are primarily used with numerical models. An alternate approach is proposed which utilizes frequency and shape information acquired from modal testing to update reduced order finite element models using exact analytical model improvement techniques. The connection degrees of freedom are then rigidly constrained in the test verified, reduced order model to provide the boundary conditions necessary for constraint modes and fixed interface normal modes. The CMS approach is then used with this test verified, reduced order model to generate the system model for further analysis. A laboratory structure is used to show the application of the technique with both numerical and simulated experimental components to describe the system and validate the proposed approach. Actual test data is then used in the approach proposed. Due to typical measurement data contaminants that are always included in any test, the measured data is further processed to remove contaminants and is then used in the proposed approach. The final case using improved data with the reduced order, test verified components is shown to produce very acceptable results from the Craig-Bampton component mode synthesis approach. Use of the technique with its strengths and weaknesses are discussed.
Evaluation philosophy for shuttle launched payloads
NASA Technical Reports Server (NTRS)
Heuser, R. E.
1975-01-01
Potential benefits of factory-to-pad testing constitute major cost savings and increase test effectiveness. Overall flight performance will be improved. The factory-to-pad approach is compatible with space shuttle processing and the large space telescope program.
Strain compatibility tests for sprayed foam cryogenic insulation
NASA Technical Reports Server (NTRS)
Hill, W. L.; Kimberlin, D. O.
1970-01-01
Mechanical stress applied to foam-coated aluminum alloy specimens maintained at cryogenic temperature simulates actual use conditions of the foam insulation. The testing reveals defects in the polyurethane foam or in the foam to metal bond.
Testing for EMC (electromagnetic compatibility) in the clinical environment.
Paperman, D; David, Y; Martinez, M
1996-01-01
Testing for electromagnetic compatibility (EMC) in the clinical environment introduces a host of complex conditions not normally encountered under laboratory conditions. In the clinical environment, various radio-frequency (RF) sources of electromagnetic interference (EMI) may be present throughout the entire spectrum of interest. Isolating and analyzing the impact from the sources of interference to medical devices involves a multidisciplinary approach based on training in, and knowledge of, the following: operation of medical devices and their susceptibility to EMI; RF propagation modalities and interaction theory; spectrum analysis systems and techniques (preferably with signature analysis capabilities) and calibrated antennas; the investigation methodology of suspected EMC problems, and testing protocols and standards. Using combinations of standard test procedures adapted for the clinical environment with personnel that have an understanding of radio-frequency behavior increases the probability of controlling, proactively, EMI in the clinical environment, thus providing for a safe and more effective patient care environment.
42 CFR 493.1278 - Standard: Histocompatibility.
Code of Federal Regulations, 2013 CFR
2013-10-01
... screening, compatibility testing and crossmatching) to be performed for each type of cell, tissue or organ... protocols for cadaver donor, living, living-related, and combined organ and tissue transplants; (ii) Testing protocols for patients at high risk for allograft rejection; and (iii) The level of testing required to...
42 CFR 493.1278 - Standard: Histocompatibility.
Code of Federal Regulations, 2014 CFR
2014-10-01
... screening, compatibility testing and crossmatching) to be performed for each type of cell, tissue or organ... protocols for cadaver donor, living, living-related, and combined organ and tissue transplants; (ii) Testing protocols for patients at high risk for allograft rejection; and (iii) The level of testing required to...
NASA Astrophysics Data System (ADS)
Toliver, Paul; Ozdur, Ibrahim; Agarwal, Anjali; Woodward, T. K.
2013-05-01
In this paper, we describe a detailed performance comparison of alternative single-pixel, single-mode LIDAR architectures including (i) linear-mode APD-based direct-detection, (ii) optically-preamplified PIN receiver, (iii) PINbased coherent-detection, and (iv) Geiger-mode single-photon-APD counting. Such a comparison is useful when considering next-generation LIDAR on a chip, which would allow one to leverage extensive waveguide-based structures and processing elements developed for telecom and apply them to small form-factor sensing applications. Models of four LIDAR transmit and receive systems are described in detail, which include not only the dominant sources of receiver noise commonly assumed in each of the four detection limits, but also additional noise terms present in realistic implementations. These receiver models are validated through the analysis of detection statistics collected from an experimental LIDAR testbed. The receiver is reconfigurable into four modes of operation, while transmit waveforms and channel characteristics are held constant. The use of a diffuse hard target highlights the importance of including speckle noise terms in the overall system analysis. All measurements are done at 1550 nm, which offers multiple system advantages including less stringent eye safety requirements and compatibility with available telecom components, optical amplification, and photonic integration. Ultimately, the experimentally-validated detection statistics can be used as part of an end-to-end system model for projecting rate, range, and resolution performance limits and tradeoffs of alternative integrated LIDAR architectures.
Li, Dongrui; Cheng, Zhigang; Chen, Gang; Liu, Fangyi; Wu, Wenbo; Yu, Jie; Gu, Ying; Liu, Fengyong; Ren, Chao; Liang, Ping
2018-04-03
To test the accuracy and efficacy of the multimodality imaging-compatible insertion robot with a respiratory motion calibration module designed for ablation of liver tumors in phantom and animal models. To evaluate and compare the influences of intervention experience on robot-assisted and ultrasound-controlled ablation procedures. Accuracy tests on rigid body/phantom model with a respiratory movement simulation device and microwave ablation tests on porcine liver tumor/rabbit liver cancer were performed with the robot we designed or with the traditional ultrasound-guidance by physicians with or without intervention experience. In the accuracy tests performed by the physicians without intervention experience, the insertion accuracy and efficiency of robot-assisted group was higher than those of ultrasound-guided group with statistically significant differences. In the microwave ablation tests performed by the physicians without intervention experience, better complete ablation rate was achieved when applying the robot. In the microwave ablation tests performed by the physicians with intervention experience, there was no statistically significant difference of the insertion number and total ablation time between the robot-assisted group and the ultrasound-controlled group. The evaluation by the NASA-TLX suggested that the robot-assisted insertion and microwave ablation process performed by physicians with or without experience were more comfortable. The multimodality imaging-compatible insertion robot with a respiratory motion calibration module designed for ablation of liver tumors could increase the insertion accuracy and ablation efficacy, and minimize the influence of the physicians' experience. The ablation procedure could be more comfortable with less stress with the application of the robot.
Development of a fiber based Raman probe compatible with interventional magnetic resonance imaging
NASA Astrophysics Data System (ADS)
Ashok, Praveen C.; Praveen, Bavishna B.; Rube, Martin; Cox, Benjamin; Melzer, Andreas; Dholakia, Kishan
2014-02-01
Raman spectroscopy has proven to be a powerful tool for discriminating between normal and abnormal tissue types. Fiber based Raman probes have demonstrated its potential for in vivo disease diagnostics. Combining Raman spectroscopy with Magnetic Resonance Imaging (MRI) opens up new avenues for MR guided minimally invasive optical biopsy. Although Raman probes are commercially available, they are not compatible with a MRI environment due to the metallic components which are used to align the micro-optic components such as filters and lenses at the probe head. Additionally they are not mechanically compatible with a typical surgical environment as factors such as sterility and length of the probe are not addressed in those designs. We have developed an MRI compatible fiber Raman probe with a disposable probe head hence maintaining sterility. The probe head was specially designed to avoid any material that would cause MR imaging artefacts. The probe head that goes into patient's body had a diameter <1.5 mm so that it is compatible with biopsy needles and catheters. The probe has been tested in MR environment and has been proven to be capable of obtaining Raman signal while the probe is under real-time MR guidance.
NASA Technical Reports Server (NTRS)
Ratcliffe, James G.
2004-01-01
The edge crack torsion (ECT) test is designed to initiate mode III delamination growth in composite laminates. The test has undergone several design changes during its development. The objective of this paper was to determine the suitability of the current ECT test design a mode III fracture test. To this end, ECT tests were conducted on specimens manufactured from IM7/8552 and S2/8552 tape laminates. Three-dimensional finite element analyses were performed. The analysis results were used to calculate the distribution of mode I, mode II, and mode III strain energy release rate along the delamination front. The results indicated that mode IIIdominated delamination growth would be initiated from the specimen center. However, in specimens of both material types, the measured values of GIIIc exhibited significant dependence on delamination length. Load-displacement response of the specimens exhibited significant deviation from linearity before specimen failure. X-radiographs of a sample of specimens revealed that damage was initiated in the specimens prior to failure. Further inspection of the failure surfaces is required to identify the damage and determine that mode III delamination is initiated in the specimens.
Adhikari, Birendra; Jones, Michael G.; Orme, Christopher J.; Wendt, Daniel S.; Wilson, Aaron D.
2015-10-01
The switchable polarity solvent forward osmosis (SPS FO) desalination process requires use of a polishing filtration step to remove trace quantities of draw solution from the product water stream. Selected nanofiltration (NF) and reverse osmosis (RO) membranes were tested for their ability to recover water from 1-cyclohexylpiperidenium bicarbonate solutions in this application. This submission includes the experimental data used to calculate NF and RO membrane flux-normalized net driving pressure (FNNDP) and flux-normalized rejection (FNR) performance in recovering water from 1-cyclohexylpiperidenium bicarbonate solutions. This data is further described and visualized in the manuscript entitled "Compatibility study of nanofiltration and reverse osmosis membranes with 1 cyclohexylpiperidenium bicarbonate solutions" (see attached Compatibility Study Manuscript).
Sensor Networking Testbed with IEEE 1451 Compatibility and Network Performance Monitoring
NASA Technical Reports Server (NTRS)
Gurkan, Deniz; Yuan, X.; Benhaddou, D.; Figueroa, F.; Morris, Jonathan
2007-01-01
Design and implementation of a testbed for testing and verifying IEEE 1451-compatible sensor systems with network performance monitoring is of significant importance. The performance parameters measurement as well as decision support systems implementation will enhance the understanding of sensor systems with plug-and-play capabilities. The paper will present the design aspects for such a testbed environment under development at University of Houston in collaboration with NASA Stennis Space Center - SSST (Smart Sensor System Testbed).
1982-01-01
Overgarment-Dynamics .............. .19 TABLES 1. Basic Anthropometry .......... ...................... 3 2. Flame Resistant CB Overgarment Test...participants (TPs) during this evaluation. Basic anthropometry of these subjects is given in Table I. TABLE 1 Basic Anthropometry Mean SD Maximum...5 S H L XL 39 H L XL XXL 43 L XL XXL XXL The areas considered were ease of doffing and donning, compatibility with prescribed clothing and field
RHETT2/EPDM Hall Thruster Propulsion System Electromagnetic Compatibility Evaluation
NASA Technical Reports Server (NTRS)
Sarmiento, Charles J.; Sankovic, John M.; Freitas, Joseph; Lynn, Peter R.
1997-01-01
Electromagnetic compatibility measurements were obtained as part of the Electric Propulsion Demonstration Module (EPDM) flight qualification program. Tests were conducted on a Hall thruster system operating at a nominal 66O W discharge power. Measurements of conducted and radiated susceptibility and emissions were obtained and referenced to MEL-STD-461 C. The power processor showed some conducted susceptibility below 4 kHz for the magnet current and discharge voltage. Radiated susceptibility testing yielded a null result. Conducted emissions showed slight violations of the specified limit for MIL-461C CE03. Radiated emissions exceeded the RE02 standard at low frequencies, below 300 MHz, by up to 40 dB RV/m/MHz.
NASA Astrophysics Data System (ADS)
Barber, Corinne; DIRC at EIC Collaboration
2015-10-01
The High-B test facility at Thomas Jefferson National Accelerator Facility allows researchers to evaluate the gain of compact photon sensors, such as Micro-Channel-Plate Photomultipliers (MCP-PMTs), in magnetic fields up to 5 T. These ongoing studies support the development of a Detector of Internally Reflected Cherenkov light (DIRC) to be used in an Electron Ion Collider (EIC). Here, we present our summer 2015 activities to upgrade and improve the facility, and we show results for MCP-PMT gain changes in high B-fields. To monitor the light stability delivered to the MCP-PMTs being tested, we implemented a Silicon Photomultiplier (SiPM) in the setup and calibrated the ADC reading this sensor. A 405-nm Light-Emitting Diode (LED) housed in an optical tube compatible with neutral density filters was also installed. The filters provide an alternative way of reducing the light output of the LED to operate the MCP-PMTs in a single-photon mode. We calibrated a set of filters by means of a photodiode and measured the photon flux at multiple positions relative to the LED. This information helped us to design 3D-printed holders unique to each MCP-PMT so that the photocathode receives the greatest amount of light. The improvements to the setup allow for more precise PMT gain evaluation. This team includes 7 collaborators/co-authors besides myself: Yordanka Ilieva, Kijun Park, Greg Kalicy, Carl Zorn, Pawel Nadel-Turonski, Tongtong Cao, and Lee.
[Development and application of component-based Chinese medicine theory].
Zhang, Jun-Hua; Fan, Guan-Wei; Zhang, Han; Fan, Xiao-Hui; Wang, Yi; Liu, Li-Mei; Li, Chuan; Gao, Yue; Gao, Xiu-Mei; Zhang, Bo-Li
2017-11-01
Traditional Chinese medicine (TCM) prescription is the main therapies for disease prevention and treatment in Chinese medicine. Following the guidance of the theory of TCM and developing drug by composing prescriptions of TCM materials and pieces, it is a traditional application mode of TCM, and still widely used in clinic. TCM prescription has theoretical advantages and rich clinical application experience in dealing with multi-factor complex diseases, but scientific research is relatively weak. The lack of scientific cognition of the effective substances and mechanism of Chinese medicine leads to insufficient understanding of the efficacy regularity, which affects the stability of effect and hinders the improvement of quality of Chinese medicinal products. Component-based Chinese medicine (CCM) is an innovation based on inheritance, which breaks through the tradition of experience-based prescription and realize the transformation of compatibility from herbal pieces to components. CCM is an important achievement during the research process of modernization of Chinese medicine. Under the support of three national "973" projects, in order to reveal the scientific connotation of the prescription compatibility theory and develop innovative Chinese drugs, we have launched theoretical innovation and technological innovation around the "two relatively clear", and opened up the research field of CCM. CCM is an innovation based on inheritance, breaking through the tradition of experience based prescription, and realizing the transformation from compatibility of herbal pieces to component compatibility, which is an important achievement of the modernization of traditional Chinese medicine. In the past more than 10 years, with the deepening of research and the expansion of application, the theory and methods of CCM and efficacy-oriented compatibility have been continuously improved. The value of CCM is not only in developing new drug, more important is to build a communication bridge between traditional Chinese medicine and modern science and construct the system of key technologies which meet the need of innovation and development of TCM. This paper focused on the research progress, related concepts and technology development of CCM, as well as its application prospect in the theory research of Chinese medicine, development of innovative Chinese drugs, secondary development of Chinese patent medicine and upgrading of pharmaceutical technology. Copyright© by the Chinese Pharmaceutical Association.
Chemical compatibility of cartridge materials
NASA Technical Reports Server (NTRS)
Wilcox, Roy C.; Zee, R. H.
1991-01-01
This twelve month progress report deals with the chemical compatibility of semiconductor crystals grown in zero gravity. Specifically, it studies the chemical compatibility between TZM, a molybdenum alloy containing titanium and zirconium, and WC 103, a titanium alloy containing Niobium and Hafnium, and Gallium arsenide (GaAs) and Cadmium Zinc Tellurite (CdZnTe). Due to the health hazards involved, three approaches were used to study the chemical compatibility between the semiconductor and cartridge materials: reaction retort, thermogravimetric analysis, and bulk cylindrical cartridge containers. A scanning electron microscope with an energy dispersive X-ray analyzer was used to examine all samples after testing. The first conclusion drawn is that reaction rates with TZM were not nearly as great as they were with WC 103. Second, the total reaction between GaAs and WC 103 was almost twice that with TZM. Therefore, even though WC 103 is easier to fabricate, at least half of the cartridge thickness will be degraded if contact is made with one of the semiconductor materials leading to a loss of strength properties.
Guide for Oxygen Compatibility Assessments on Oxygen Components and Systems
NASA Technical Reports Server (NTRS)
Rosales, Keisa R.; Shoffstall, Michael S.; Stoltzfus, Joel M.
2007-01-01
Understanding and preventing fire hazards is necessary when designing, maintaining, and operating oxygen systems. Ignition risks can be minimized by controlling heat sources and using materials that will not ignite or will not support burning in the end-use environment. Because certain materials are more susceptible to ignition in oxygen-enriched environments, a compatibility assessment should be performed before the component is introduced into an oxygen system. This document provides an overview of oxygen fire hazards and procedures that are consistent with the latest versions of American Society for Testing and Materials (ASTM) Standards G63 (1999) and G94 (2005) to address fire hazards associated with oxygen systems. This document supersedes the previous edition, NASA Technical Memorandum 104823, Guide for Oxygen Hazards Analyses on Components and Systems (1996). The step-by-step oxygen compatibility assessment method described herein (see Section 4) enables oxygen-system designers, system engineers, and facility managers to determine areas of concern with respect to oxygen compatibility and, ultimately, prevent damage to a system or injury to personnel.
Hu, Xiao-Min; Chen, Jiang-Shan; Liu, Bi-Heng; Guo, Yu; Huang, Yun-Feng; Zhou, Zong-Quan; Han, Yong-Jian; Li, Chuan-Feng; Guo, Guang-Can
2016-10-21
The physical impact and the testability of the Kochen-Specker (KS) theorem is debated because of the fact that perfect compatibility in a single quantum system cannot be achieved in practical experiments with finite precision. Here, we follow the proposal of A. Cabello and M. T. Cunha [Phys. Rev. Lett. 106, 190401 (2011)], and present a compatibility-loophole-free experimental violation of an inequality of noncontextual theories by two spatially separated entangled qutrits. A maximally entangled qutrit-qutrit state with a fidelity as high as 0.975±0.001 is prepared and distributed to separated spaces, and these two photons are then measured locally, providing the compatibility requirement. The results show that the inequality for noncontextual theory is violated by 31 standard deviations. Our experiments pave the way to close the debate about the testability of the KS theorem. In addition, the method to generate high-fidelity and high-dimension entangled states will provide significant advantages in high-dimension quantum encoding and quantum communication.
Földes, Noémi; Philipp, Andrea M; Badets, Arnaud; Koch, Iring
2018-05-01
The ideomotor principle states that actions are represented by their anticipated sensory effects. This notion is often tested using the response-effect compatibility (REC) paradigm, where participants' responses are followed either by a compatible or incompatible response effect (e.g., an effect on the right side after a right-hand response is considered R-E compatible due to the spatial overlap, whereas an effect on the left side after the right-hand response is considered incompatible). Shorter reaction times are typically observed in the compatible condition compared to the incompatible condition (i.e., REC effect), suggesting that effect anticipation plays a role in action control. Previous evidence from verbal REC suggested that effect anticipation can be due to conceptual R-E overlap, but there was also phonological overlap (i.e., anticipated reading of a word preceded by the vocal response of saying that very word). To examine the representational basis of REC, in three experiments, we introduced a bilingual R-E mapping to exclude phonological R-E overlap (i.e., in the R-E compatible condition, the translation equivalent of the response word is presented as an effect word in a different language). Our findings show that the REC effect is obtained when presenting the effect word in the same language as the response (i.e., monolingual condition), but the compatibility effect was not found when the semantically same word is presented in a different language, suggesting no conceptually generalized REC in a bilingual setting. (232 words). Copyright © 2018 Elsevier B.V. All rights reserved.