Sample records for test facility improvements

  1. Recent Upgrades at the Fermilab Test Beam Facility

    NASA Astrophysics Data System (ADS)

    Rominsky, Mandy

    2016-03-01

    The Fermilab Test Beam Facility is a world class facility for testing and characterizing particle detectors. The facility has been in operation since 2005 and has undergone significant upgrades in the last two years. A second beam line with cryogenic support has been added and the facility has adopted the MIDAS data acquisition system. The facility also recently added a cosmic telescope test stand and improved tracking capabilities. With two operational beam lines, the facility can deliver a variety of particle types and momenta ranging from 120 GeV protons in the primary beam line down to 200 MeV particles in the tertiary beam line. In addition, recent work has focused on analyzing the beam structure to provide users with information on the data they are collecting. With these improvements, the Fermilab Test Beam facility is capable of supporting High Energy physics applications as well as industry users. The upgrades will be discussed along with plans for future improvements.

  2. Coupled Facility/Payload Vibration Modeling Improvements

    NASA Technical Reports Server (NTRS)

    Carnahan, Timothy M.; Kaiser, Michael

    2015-01-01

    A major phase of aerospace hardware verification is vibration testing. The standard approach for such testing is to use a shaker to induce loads into the payload. In preparation for vibration testing at NASA/GSFC there is an analysis to assess the responses of the payload. A new method of modeling the test is presented that takes into account dynamic interactions between the facility and the payload. This dynamic interaction has affected testing in the past, but been ignored or adjusted for during testing. By modeling the combination of the facility and test article (payload) it is possible to improve the prediction of hardware responses. Many aerospace test facilities work in similar way to those at NASA Goddard Space Flight Center. Lessons learned here should be applicable to other test facilities with similar setups.

  3. Test Activities in the Langley Transonic Dynamics Tunnel and a Summary of Recent Facility Improvements

    NASA Technical Reports Server (NTRS)

    Cole, Stanley R.; Johnson, R. Keith; Piatak, David J.; Florance, Jennifer P.; Rivera, Jose A., Jr.

    2003-01-01

    The Langley Transonic Dynamics Tunnel (TDT) has provided a unique capability for aeroelastic testing for over forty years. The facility has a rich history of significant contributions to the design of many United States commercial transports, military aircraft, launch vehicles, and spacecraft. The facility has many features that contribute to its uniqueness for aeroelasticity testing, perhaps the most important feature being the use of a heavy gas test medium to achieve higher test densities compared to testing in air. Higher test medium densities substantially improve model-building requirements and therefore simplify the fabrication process for building aeroelastically scaled wind tunnel models. This paper describes TDT capabilities that make it particularly suited for aeroelasticity testing. The paper also discusses the nature of recent test activities in the TDT, including summaries of several specific tests. Finally, the paper documents recent facility improvement projects and the continuous statistical quality assessment effort for the TDT.

  4. Improved E-ELT subsystem and component specifications, thanks to M1 test facility

    NASA Astrophysics Data System (ADS)

    Dimmler, M.; Marrero, J.; Leveque, S.; Barriga, Pablo; Sedghi, B.; Kornweibel, N.

    2014-07-01

    During the last 2 years ESO has operated the "M1 Test Facility", a test stand consisting of a representative section of the E-ELT primary mirror equipped with 4 complete prototype segment subunits including sensors, actuators and control system. The purpose of the test facility is twofold: it serves to study and get familiar with component and system aspects like calibration, alignment and handling procedures and suitable control strategies on real hardware long before the primary mirror (hereafter M1) components are commissioned. Secondly, and of major benefit to the project, it offered the possibility to evaluate component and subsystem performance and interface issues in a system context in such detail, that issues could be identified early enough to feed back into the subsystem and component specifications. This considerably reduces risk and cost of the production units and allows refocusing the project team on important issues for the follow-up of the production contracts. Experiences are presented in which areas the results of the M1 Test Facility particularly helped to improve subsystem specifications and areas, where additional tests were adopted independent of the main test facility. Presented are the key experiences of the M1 Test Facility which lead to improved specifications or identified the need for additional testing outside of the M1 Test Facility.

  5. The Planning and Implementation of Test Facility Improvements

    NASA Technical Reports Server (NTRS)

    Oberlander, Larry

    2008-01-01

    As engineering programs develop, and product testing begins, ideas for process improvement soon become obvious. Engineers envision new holding and handling fixtures. Additional custom-made support equipment may be needed. Perhaps modifications to the building or modifications to facility hardware are the order of the day. This is where a flexible creative test organization is needed. We need not be content with the status quo. All of these desired test innovations can make the difficult easy and improve the work flow. At times, implementing these new ideas demands more time or specialized expertise than test team members have. Through the coordinated use of labor resources, the needed improvements can still be made and in a timely fashion that supports program schedules. This presentation provides practical advice and a method whereby test personnel can creatively develop facility improvements and manage them from start to finish. You can control just how much time you invest and what part of your concepts you will personally design. By wisely defining the requirements and presenting them to the appropriate help sources (vendors, contractors, coworkers, and support departments), you can get the help you need to bring the improvements you have conceived, into fruition. Aspects of this presentation include defining requirements for test facility improvements, choosing labor resources, writing a statement of work, determining cost and benefits, securing department approval, coordinating procurement, managing the project, and training the end users. The process of successfully implementing test facility improvements is thoroughly explained. It has been tried, proven and improved over nearly 25 years of use. Whether considering a $50 improvement or a $50 million dollar improvement, this discussion will provide helpful pointers. Examples of improvements made through this process and their illustration will be included.

  6. Coupled Facility-Payload Vibration Modeling Improvements

    NASA Technical Reports Server (NTRS)

    Carnahan, Timothy M.; Kaiser, Michael A.

    2015-01-01

    A major phase of aerospace hardware verification is vibration testing. The standard approach for such testing is to use a shaker to induce loads into the payload. In preparation for vibration testing at National Aeronautics and Space Administration/Goddard Space Flight Center an analysis is performed to assess the responses of the payload. A new method of modeling the test is presented that takes into account dynamic interactions between the facility and the payload. This dynamic interaction has affected testing in the past, but been ignored or adjusted for during testing. By modeling the combined dynamics of the facility and test article (payload) it is possible to improve the prediction of hardware responses. Many aerospace test facilities work in similar way to those at NASA/Goddard Space Flight Center. Lessons learned here should be applicable to other test facilities with similar setups.

  7. Progress in Flaps Down Flight Reynolds Number Testing Techniques at the NTF

    NASA Technical Reports Server (NTRS)

    Payne, Frank; Bosetti, Cris; Gatlin, Greg; Tuttle, Dave; Griffiths, Bob

    2007-01-01

    A series of NASA/Boeing cooperative low speed wind tunnel tests was conducted in the National Transonic Facility (NTF) between 2003 and 2004 using a semi-span high lift model representative of the 777-200 aircraft. The objective of this work was to develop the capability to acquire high quality, low speed (flaps down) wind tunnel data at up to flight Reynolds numbers in a facility originally optimized for high speed full span models. In the course of testing, a number of facility and procedural improvements were identified and implemented. The impact of these improvements on key testing metrics data quality, productivity, and so forth - was significant, and is discussed here, together with the relevance of these metrics as applied to cryogenic wind tunnel testing in general. Details of the improvements at the NTF are discussed in AIAA-2006-0508 (Recent Improvements in Semi-span Testing at the National Transonic Facility). The development work at the NTF culminated with validation testing of a 787-8 semi-span model at full flight Reynolds number in the first quarter of 2006.

  8. Langley Research Center's Unitary Plan Wind Tunnel: Testing Capabilities and Recent Modernization Activities

    NASA Technical Reports Server (NTRS)

    Micol, John R.

    2001-01-01

    Description, capabilities, initiatives, and utilization of the NASA Langley Research Center's Unitary Plan Wind Tunnel are presented. A brief overview of the facility's operational capabilities and testing techniques is provided. A recent Construction of Facilities (CoF) project to improve facility productivity and efficiency through facility automation has been completed and is discussed. Several new and maturing thrusts are underway that include systematic efforts to provide credible assessment for data quality, modifications to the new automation control system for increased compatibility with the Modern Design Of Experiments (MDOE) testing methodology, and process improvements for better test coordination, planning, and execution.

  9. Langley Research Center's Unitary Plan Wind Tunnel: Testing Capabilities and Recent Modernization Activities

    NASA Technical Reports Server (NTRS)

    Micol, John R.

    2001-01-01

    Description, capabilities, initiatives, and utilization of the NASA Langley Research Center's Unitary Plan Wind Tunnel are presented. A brief overview of the facility's operational capabilities and testing techniques is provided. A recent Construction of Facilities (Car) project to improve facility productivity and efficiency through facility automation has been completed and is discussed. Several new and maturing thrusts are underway that include systematic efforts to provide credible assessment for data quality, modifications to the new automation control system for increased compatibility with the Modern Design of Experiments (MDOE) testing methodology, and process improvements for better test coordination, planning, and execution.

  10. Advancing Test Capabilities at NASA Wind Tunnels

    NASA Technical Reports Server (NTRS)

    Bell, James

    2015-01-01

    NASA maintains twelve major wind tunnels at three field centers capable of providing flows at 0.1 M 10 and unit Reynolds numbers up to 45106m. The maintenance and enhancement of these facilities is handled through a unified management structure under NASAs Aeronautics and Evaluation and Test Capability (AETC) project. The AETC facilities are; the 11x11 transonic and 9x7 supersonic wind tunnels at NASA Ames; the 10x10 and 8x6 supersonic wind tunnels, 9x15 low speed tunnel, Icing Research Tunnel, and Propulsion Simulator Laboratory, all at NASA Glenn; and the National Transonic Facility, Transonic Dynamics Tunnel, LAL aerothermodynamics laboratory, 8 High Temperature Tunnel, and 14x22 low speed tunnel, all at NASA Langley. This presentation describes the primary AETC facilities and their current capabilities, as well as improvements which are planned over the next five years. These improvements fall into three categories. The first are operations and maintenance improvements designed to increase the efficiency and reliability of the wind tunnels. These include new (possibly composite) fan blades at several facilities, new temperature control systems, and new and much more capable facility data systems. The second category of improvements are facility capability advancements. These include significant improvements to optical access in wind tunnel test sections at Ames, improvements to test section acoustics at Glenn and Langley, the development of a Supercooled Large Droplet capability for icing research, and the development of an icing capability for large engine testing. The final category of improvements consists of test technology enhancements which provide value across multiple facilities. These include projects to increase balance accuracy, provide NIST-traceable calibration characterization for wind tunnels, and to advance optical instruments for Computational Fluid Dynamics (CFD) validation. Taken as a whole, these individual projects provide significant enhancements to NASA capabilities in ground-based testing. They ensure that these wind tunnels will provide accurate and relevant experimental data for years to come, supporting both NASAs mission and the missions of our government and industry customers.

  11. Advances in Engine Test Capabilities at the NASA Glenn Research Center's Propulsion Systems Laboratory

    NASA Technical Reports Server (NTRS)

    Pachlhofer, Peter M.; Panek, Joseph W.; Dicki, Dennis J.; Piendl, Barry R.; Lizanich, Paul J.; Klann, Gary A.

    2006-01-01

    The Propulsion Systems Laboratory at the National Aeronautics and Space Administration (NASA) Glenn Research Center is one of the premier U.S. facilities for research on advanced aeropropulsion systems. The facility can simulate a wide range of altitude and Mach number conditions while supplying the aeropropulsion system with all the support services necessary to operate at those conditions. Test data are recorded on a combination of steady-state and highspeed data-acquisition systems. Recently a number of upgrades were made to the facility to meet demanding new requirements for the latest aeropropulsion concepts and to improve operational efficiency. Improvements were made to data-acquisition systems, facility and engine-control systems, test-condition simulation systems, video capture and display capabilities, and personnel training procedures. This paper discusses the facility s capabilities, recent upgrades, and planned future improvements.

  12. Realistic Development and Testing of Fission System at a Non-Nuclear Testing Facility

    NASA Technical Reports Server (NTRS)

    Godfroy, Tom; VanDyke, Melissa; Dickens, Ricky; Pedersen, Kevin; Lenard, Roger; Houts, Mike

    2000-01-01

    The use of resistance heaters to simulate heat from fission allows extensive development of fission systems to be performed in non-nuclear test facilities, saving time and money. Resistance heated tests on a module has been performed at the Marshall Space Flight Center in the Propellant Energy Source Testbed (PEST). This paper discusses the experimental facilities and equipment used for performing resistance heated tests. Recommendations are made for improving non-nuclear test facilities and equipment for simulated testing of nuclear systems.

  13. Realistic development and testing of fission systems at a non-nuclear testing facility

    NASA Astrophysics Data System (ADS)

    Godfroy, Tom; van Dyke, Melissa; Dickens, Ricky; Pedersen, Kevin; Lenard, Roger; Houts, Mike

    2000-01-01

    The use of resistance heaters to simulate heat from fission allows extensive development of fission systems to be performed in non-nuclear test facilities, saving time and money. Resistance heated tests on a module has been performed at the Marshall Space Flight Center in the Propellant Energy Source Testbed (PEST). This paper discusses the experimental facilities and equipment used for performing resistance heated tests. Recommendations are made for improving non-nuclear test facilities and equipment for simulated testing of nuclear systems. .

  14. Recent Improvements in Semi-Span Testing at the National Transonic Facility (Invited)

    NASA Technical Reports Server (NTRS)

    Gatlin, G. M.; Tomek, W. G.; Payne, F. M.; Griffiths, R. C.

    2006-01-01

    Three wind tunnel investigations of a commercial transport, high-lift, semi-span configuration have recently been conducted in the National Transonic Facility at the NASA Langley Research Center. Throughout the course of these investigations multiple improvements have been developed in the facility semi-span test capability. The primary purpose of the investigations was to assess Reynolds number scale effects on a modern commercial transport configuration up to full-scale flight test conditions (Reynolds numbers on the order of 27 million). The tests included longitudinal aerodynamic studies at subsonic takeoff and landing conditions across a range of Reynolds numbers from that available in conventional wind tunnels up to flight conditions. The purpose of this paper is to discuss lessons learned and improvements incorporated into the semi-span testing process. Topics addressed include enhanced thermal stabilization and moisture reduction procedures, assessments and improvements in model sealing techniques, compensation of model reference dimensions due to test temperature, significantly improved semi-span model access capability, and assessments of data repeatability.

  15. Universal opt-out screening for hepatitis C virus (HCV) within correctional facilities is an effective intervention to improve public health.

    PubMed

    Morris, Meghan D; Brown, Brandon; Allen, Scott A

    2017-09-11

    Purpose Worldwide efforts to identify individuals infected with the hepatitis C virus (HCV) focus almost exclusively on community healthcare systems, thereby failing to reach high-risk populations and those with poor access to primary care. In the USA, community-based HCV testing policies and guidelines overlook correctional facilities, where HCV rates are believed to be as high as 40 percent. This is a missed opportunity: more than ten million Americans move through correctional facilities each year. Herein, the purpose of this paper is to examine HCV testing practices in the US correctional system, California and describe how universal opt-out HCV testing could expand early HCV detection, improve public health in correctional facilities and communities, and prove cost-effective over time. Design/methodology/approach A commentary on the value of standardizing screening programs across facilities by mandating all facilities (universal) to implement opt-out testing policies for all prisoners upon entry to the correctional facilities. Findings Current variability in facility-level testing programs results in inconsistent testing levels across correctional facilities, and therefore makes estimating the actual number of HCV-infected adults in the USA difficult. The authors argue that universal opt-out testing policies ensure earlier diagnosis of HCV among a population most affected by the disease and is more cost-effective than selective testing policies. Originality/value The commentary explores the current limitations of selective testing policies in correctional systems and provides recommendations and implications for public health and correctional organizations.

  16. Improving Tanzanian childbirth service quality.

    PubMed

    Jaribu, Jennie; Penfold, Suzanne; Green, Cathy; Manzi, Fatuma; Schellenberg, Joanna

    2018-04-16

    Purpose The purpose of this paper is to describe a quality improvement (QI) intervention in primary health facilities providing childbirth care in rural Southern Tanzania. Design/methodology/approach A QI collaborative model involving district managers and health facility staff was piloted for 6 months in 4 health facilities in Mtwara Rural district and implemented for 18 months in 23 primary health facilities in Ruangwa district. The model brings together healthcare providers from different health facilities in interactive workshops by: applying QI methods to generate and test change ideas in their own facilities; using local data to monitor improvement and decision making; and health facility supervision visits by project and district mentors. The topics for improving childbirth were deliveries and partographs. Findings Median monthly deliveries increased in 4 months from 38 (IQR 37-40) to 65 (IQR 53-71) in Mtwara Rural district, and in 17 months in Ruangwa district from 110 (IQR 103-125) to 161 (IQR 148-174). In Ruangwa health facilities, the women for whom partographs were used to monitor labour progress increased from 10 to 57 per cent in 17 months. Research limitations/implications The time for QI innovation, testing and implementation phases was limited, and the study only looked at trends. The outcomes were limited to process rather than health outcome measures. Originality/value Healthcare providers became confident in the QI method through engagement, generating and testing their own change ideas, and observing improvements. The findings suggest that implementing a QI initiative is feasible in rural, low-income settings.

  17. DFL, Canada's Space AIT Facilities - Current and Planned Capabilities

    NASA Astrophysics Data System (ADS)

    Singhal, R.; Mishra, S.; Choueiry, E.; Dumoulin, J.; Ahmed, S.

    2004-08-01

    The David Florida Laboratory (DFL) of the Canadian Space Agency is the Canadian national ISO 9001:2000 registered facility for the assembly, integration, and (environmental) testing of space hardware. This paper briefly describes the three main qualification facilities: Structural Qualification Facilities (SQF); Radio Frequency Qualification Facilities (RFQF); and Thermal Qualification Facilities (TQF). The paper also describes the planned/new upgrades/improvements to the DFL's existing capabilities. These include: cylindrical near-field antenna measurement system, current capabilities in multi-frequency multi-band passive intermodulation (PIM) measurement; combined thermal/vibration test facility, improvement in efficiency and performance of the photogrammetry capability, acquisition of an additional mass properties measurement system for small and micro-satellites; combined control and data acquisition system for all existing thermal vacuum facilities, plus a new automatic thermal control system and hypobaric chamber.

  18. The Nature of Scatter at the DARHT Facility and Suggestions for Improved Modeling of DARHT Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morneau, Rachel Anne

    This report describes the US Stockpile Stewardship Program which is meant to sustain and evaluate nuclear weapon stockpile with no underground nuclear tests. This research will focus on DARHT, the Dual Axis Radiographic Hydrodynamic Test facility.

  19. Improved Cryogenic Optical Test Capability at Marshall Space Flight Center's X-ray Cryogenic Test Facility

    NASA Technical Reports Server (NTRS)

    Kegley, Jeffrey; Haight, Harlan; Hogue, William; Carpenter, Jay; Siler, Richard; Wright, Ernie; Eng, Ron; Baker, Mark; McCracken, Jeff

    2005-01-01

    Marshall Space Flight Center's X-ray & Cryogenic Test Facility (XRCF) has been performing optical wavefront testing and thermal structural deformation testing at subliquid nitrogen cryogenic temperatures since 1999. Recent modifications have been made to the facility in support of the James Webb Space Telescope (JWST) program. The test article envelope and the chamber's refrigeration capacity have both been increased. A new larger helium-cooled enclosure has been added to the existing enclosure increasing both the cross-sectional area and the length. This new enclosure is capable of supporting six JWST Primary Mirror Segment Assemblies. A second helium refrigeration system has been installed essentially doubling the cooling capacity available at the facility. Modifications have also been made to the optical instrumentation area. Improved access is now available for both the installation and operation of optical instrumentation outside the vacuum chamber. Chamber configuration, specifications, and performance data will be presented.

  20. Upgrade of the cryogenic CERN RF test facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pirotte, O.; Benda, V.; Brunner, O.

    2014-01-29

    With the large number of superconducting radiofrequency (RF) cryomodules to be tested for the former LEP and the present LHC accelerator a RF test facility was erected early in the 1990’s in the largest cryogenic test facility at CERN located at Point 18. This facility consisted of four vertical test stands for single cavities and originally one and then two horizontal test benches for RF cryomodules operating at 4.5 K in saturated helium. CERN is presently working on the upgrade of its accelerator infrastructure, which requires new superconducting cavities operating below 2 K in saturated superfluid helium. Consequently, the RFmore » test facility has been renewed in order to allow efficient cavity and cryomodule tests in superfluid helium and to improve its thermal performances. The new RF test facility is described and its performances are presented.« less

  1. Cryogenic Test Capability at Marshall Space Flight Center's X-ray Cryogenic Test Facility

    NASA Technical Reports Server (NTRS)

    Kegley, Jeffrey; Baker, Mark; Carpenter, Jay; Eng, Ron; Haight, Harlan; Hogue, William; McCracken, Jeff; Siler, Richard; Wright, Ernie

    2006-01-01

    Marshall Space Flight Center's X-ray & Cryogenic Test Facility (XRCF) has been performing sub-liquid nitrogen temperature testing since 1999. Optical wavefront measurement, thermal structural deformation, mechanism functional & calibration, and simple cryo-conditioning tests have been completed. Recent modifications have been made to the facility in support of the James Webb Space Telescope (JWST) program. The chamber's payload envelope and the facility s refrigeration capacity have both been increased. Modifications have also been made to the optical instrumentation area improving access for both the installation and operation of optical instrumentation outside the vacuum chamber. The facility's capabilities, configuration, and performance data will be presented.

  2. Good Laboratory Practices of Materials Testing at NASA White Sands Test Facility

    NASA Technical Reports Server (NTRS)

    Hirsch, David; Williams, James H.

    2005-01-01

    An approach to good laboratory practices of materials testing at NASA White Sands Test Facility is presented. The contents include: 1) Current approach; 2) Data analysis; and 3) Improvements sought by WSTF to enhance the diagnostic capability of existing methods.

  3. Recent National Transonic Facility Test Process Improvements (Invited)

    NASA Technical Reports Server (NTRS)

    Kilgore, W. A.; Balakrishna, S.; Bobbitt, C. W., Jr.; Adcock, J. B.

    2001-01-01

    This paper describes the results of two recent process improvements; drag feed-forward Mach number control and simultaneous force/moment and pressure testing, at the National Transonic Facility. These improvements have reduced the duration and cost of testing. The drag feed-forward Mach number control reduces the Mach number settling time by using measured model drag in the Mach number control algorithm. Simultaneous force/moment and pressure testing allows simultaneous collection of force/moment and pressure data without sacrificing data quality thereby reducing the overall testing time. Both improvements can be implemented at any wind tunnel. Additionally the NTF is working to develop and implement continuous pitch as a testing option as an additional method to reduce costs and maintain data quality.

  4. Recent National Transonic Facility Test Process Improvements (Invited)

    NASA Technical Reports Server (NTRS)

    Kilgore, W. A.; Balakrishna, S.; Bobbitt, C. W., Jr.; Adcock, J. B.

    2001-01-01

    This paper describes the results of two recent process improvements; drag feed-forward Mach number control and simultaneous force/moment and pressure testing, at the National Transonic Facility. These improvements have reduced the duration and cost of testing. The drag feedforward Mach number control reduces the Mach number settling time by using measured model drag in the Mach number control algorithm. Simultaneous force/moment and pressure testing allows simultaneous collection of force/moment and pressure data without sacrificing data quality thereby reducing the overall testing time. Both improvements can be implemented at any wind tunnel. Additionally the NTF is working to develop and implement continuous pitch as a testing option as an additional method to reduce costs and maintain data quality.

  5. Recent Productivity Improvements to the National Transonic Facility

    NASA Technical Reports Server (NTRS)

    Popernack, Thomas G., Jr.; Sydnor, George H.

    1998-01-01

    Productivity gains have recently been made at the National Transonic Facility wind tunnel at NASA Langley Research Center. A team was assigned to assess and set productivity goals to achieve the desired operating cost and output of the facility. Simulations have been developed to show the sensitivity of selected process productivity improvements in critical areas to reduce overall test cycle times. The improvements consist of an expanded liquid nitrogen storage system, a new fan drive, a new tunnel vent stack heater, replacement of programmable logic controllers, an increased data communications speed, automated test sequencing, and a faster model changeout system. Where possible, quantifiable results of these improvements are presented. Results show that in most cases, improvements meet the productivity gains predicted by the simulations.

  6. 77 FR 2829 - Energy Conservation Program: Test Procedure for Television Sets

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-19

    ... provisions designed to improve energy efficiency. (All references to EPCA refer to the statute as amended... also provides that the test procedure shall be reasonably designed to produce test results which... facility one is denoted with numerical values, while the data from test facility two is denoted with...

  7. Ergonomics and simulation-based approach in improving facility layout

    NASA Astrophysics Data System (ADS)

    Abad, Jocelyn D.

    2018-02-01

    The use of the simulation-based technique in facility layout has been a choice in the industry due to its convenience and efficient generation of results. Nevertheless, the solutions generated are not capable of addressing delays due to worker's health and safety which significantly impact overall operational efficiency. It is, therefore, critical to incorporate ergonomics in facility design. In this study, workstation analysis was incorporated into Promodel simulation to improve the facility layout of a garment manufacturing. To test the effectiveness of the method, existing and improved facility designs were measured using comprehensive risk level, efficiency, and productivity. Results indicated that the improved facility layout generated a decrease in comprehensive risk level and rapid upper limb assessment score; an increase of 78% in efficiency and 194% increase in productivity compared to existing design and thus proved that the approach is effective in attaining overall facility design improvement.

  8. Feasibility study and verified design concept for new improved hot gas facility

    NASA Technical Reports Server (NTRS)

    1986-01-01

    The MSFC Hot Gas Facility (HGF) was fabricated in 1975 as a temporary facility to provide immediate turnaround testing to support the SRB and ET TPS development. This facility proved to be very useful and was used to make more than 1300 runs, far more than ever intended in the original design. Therefore, it was in need of constant repair and needed to be replaced with a new improved design to support the continuing SRB/ET TPS product improvement and/or removal efforts. MSFC contracted with Lockheed-Huntsville to work on this improved design through contract NAS8-36304 Feasibility Study and Verified Design Concept for the New Improved Hot Gas Facility. The results of Lockheed-Huntsville's efforts under this contract are summarized.

  9. Quality of antenatal and delivery care before and after the implementation of a prevention of mother-to-child HIV transmission programme in Côte d'Ivoire.

    PubMed

    Delvaux, Thérèse; Konan, Jean-Paul Diby; Aké-Tano, Odile; Gohou-Kouassi, Valérie; Bosso, Patrice Emery; Buvé, Anne; Ronsmans, Carine

    2008-08-01

    To assess whether implementation of a prevention of mother-to-child HIV transmission (PMTCT) programme in Côte d'Ivoire improved the quality of antenatal and delivery care services. Quality of antenatal and delivery care services was assessed in five urban health facilities before (2002-2003) and after (2005) the implementation of a PMTCT programme through review of facility data; observation of antenatal consultations (n = 606 before; n = 591 after) and deliveries (n = 229 before; n = 231 after) and exit interviews of women; and interviews of health facility staff. HIV testing was never proposed at baseline and was proposed to 63% of women at the first ANC visit after PMTCT implementation. The overall testing rate was 42% and 83% of tested HIV-infected pregnant women received nevirapine. In addition, inter-personal communication and confidentiality significantly improved in all health facilities. In the maternity ward, quality of obstetrical care at admission, delivery and post-partum care globally improved in all facilities after the implementation of the programme although some indicators remained poor, such as filling in the partograph directly during labour. Episiotomy rates among primiparous women dropped from 64% to 25% (P < 0.001) after PMTCT implementation. Global scores for quality of antenatal and delivery care significantly improved in all facilities after the implementation of the programme. Introducing comprehensive PMTCT services can improve the quality of antenatal and delivery care in general.

  10. Assessing healthcare quality using routine data: evaluating the performance of the national tuberculosis programme in South Africa.

    PubMed

    McLaren, Zoë M; Sharp, Alana R; Zhou, Jifang; Wasserman, Sean; Nanoo, Ananta

    2017-02-01

    To assess the performance of healthcare facilities by means of indicators based on guidelines for clinical care of TB, which is likely a good measure of overall facility quality. We assessed quality of care in all public health facilities in South Africa using graphical, correlation and locally weighted kernel regression analysis of routine TB test data. Facility performance falls short of national standards of care. Only 74% of patients with TB provided a second specimen for testing, 18% received follow-up testing and 14% received drug resistance testing. Only resistance testing rates improved over time, tripling between 2004 and 2011. National awareness campaigns and changes in clinical guidelines had only a transient impact on testing rates. The poorest performing facilities remained at the bottom of the rankings over the period of study. The optimal policy strategy requires both broad-based policies and targeted resources to poor performers. This approach to assessing facility quality of care can be adapted to other contexts and also provides a low-cost method for evaluating the effectiveness of proposed interventions. Devising targeted policies based on routine data is a cost-effective way to improve the quality of public health care provided. © 2016 John Wiley & Sons Ltd.

  11. Past, Present, and Future Capabilities of the Transonic Dynamics Tunnel from an Aeroelasticity Perspective

    NASA Technical Reports Server (NTRS)

    Cole, Stanley R.; Garcia, Jerry L.

    2000-01-01

    The NASA Langley Transonic Dynamics Tunnel (TDT) has provided a unique capability for aeroelastic testing for forty years. The facility has a rich history of significant contributions to the design of many United States commercial transports, military aircraft, launch vehicles, and spacecraft. The facility has many features that contribute to its uniqueness for aeroelasticity testing, perhaps the most important feature being the use of a heavy gas test medium to achieve higher test densities. Higher test medium densities substantially improve model-building requirements and therefore simplify the fabrication process for building aeroelastically scaled wind tunnel models. Aeroelastic scaling for the heavy gas results in lower model structural frequencies. Lower model frequencies tend to a make aeroelastic testing safer. This paper will describe major developments in the testing capabilities at the TDT throughout its history, the current status of the facility, and planned additions and improvements to its capabilities in the near future.

  12. Quality Improvement Intervention for Reduction of Redundant Testing.

    PubMed

    Ducatman, Alan M; Tacker, Danyel H; Ducatman, Barbara S; Long, Dustin; Perrotta, Peter L; Lawther, Hannah; Pennington, Kelly; Lander, Owen; Warden, Mary; Failinger, Conard; Halbritter, Kevin; Pellegrino, Ronald; Treese, Marney; Stead, Jeffrey A; Glass, Eric; Cianciaruso, Lauren; Nau, Konrad C

    2017-01-01

    Laboratory data are critical to analyzing and improving clinical quality. In the setting of residual use of creatine kinase M and B isoenzyme testing for myocardial infarction, we assessed disease outcomes of discordant creatine kinase M and B isoenzyme +/troponin I (-) test pairs in order to address anticipated clinician concerns about potential loss of case-finding sensitivity following proposed discontinuation of routine creatine kinase and creatine kinase M and B isoenzyme testing. Time-sequenced interventions were introduced. The main outcome was the percentage of cardiac marker studies performed within guidelines. Nonguideline orders dominated at baseline. Creatine kinase M and B isoenzyme testing in 7496 order sets failed to detect additional myocardial infarctions but was associated with 42 potentially preventable admissions/quarter. Interruptive computerized soft stops improved guideline compliance from 32.3% to 58% ( P < .001) in services not receiving peer leader intervention and to >80% ( P < .001) with peer leadership that featured dashboard feedback about test order performance. This successful experience was recapitulated in interrupted time series within 2 additional services within facility 1 and then in 2 external hospitals (including a critical access facility). Improvements have been sustained postintervention. Laboratory cost savings at the academic facility were estimated to be ≥US$635 000 per year. National collaborative data indicated that facility 1 improved its order patterns from fourth to first quartile compared to peer norms and imply that nonguideline orders persist elsewhere. This example illustrates how pathologists can provide leadership in assisting clinicians in changing laboratory ordering practices. We found that clinicians respond to local laboratory data about their own test performance and that evidence suggesting harm is more compelling to clinicians than evidence of cost savings. Our experience indicates that interventions done at an academic facility can be readily instituted by private practitioners at external facilities. The intervention data also supplement existing literature that electronic order interruptions are more successful when combined with modalities that rely on peer education combined with dashboard feedback about laboratory order performance. The findings may have implications for the role of the pathology laboratory in the ongoing pivot from quantity-based to value-based health care.

  13. Program for the improvement of downhole drilling motor bearings and seals. Phase IV. Semi-annual report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tibbitts, G.A.; DeLafosse, P.H.; Black, A.

    1980-07-01

    Four main areas of development for the project are covered: design and fabrication of a dynamometer and a mud cooling system for the Bearing-Seal Package Test Facility; modification of the Bearing-Seal Package Test Facility based on test results; testing of new lubricant samples from Pacer Lubricants, Inc., in the Terra Tek High Temperature Lubricant Tester; and testing of new seal types in the Terra Tek Sea Tester. The Maurer Engineering Report, Semi-Annual Progress Report on Improvement of Downhole Motor Bearings and Seals by Jeff L. Barnwell, has been included as Appendix B.

  14. Accreditation status and geographic location of outpatient vascular testing facilities among Medicare beneficiaries: the VALUE (Vascular Accreditation, Location & Utilization Evaluation) study.

    PubMed

    Rundek, Tatjana; Brown, Scott C; Wang, Kefeng; Dong, Chuanhui; Farrell, Mary Beth; Heller, Gary V; Gornik, Heather L; Hutchisson, Marge; Needleman, Laurence; Benenati, James F; Jaff, Michael R; Meier, George H; Perese, Susana; Bendick, Phillip; Hamburg, Naomi M; Lohr, Joann M; LaPerna, Lucy; Leers, Steven A; Lilly, Michael P; Tegeler, Charles; Alexandrov, Andrei V; Katanick, Sandra L

    2014-10-01

    There is limited information on the accreditation status and geographic distribution of vascular testing facilities in the US. The Centers for Medicare & Medicaid Services (CMS) provide reimbursement to facilities regardless of accreditation status. The aims were to: (1) identify the proportion of Intersocietal Accreditation Commission (IAC) accredited vascular testing facilities in a 5% random national sample of Medicare beneficiaries receiving outpatient vascular testing services; (2) describe the geographic distribution of these facilities. The VALUE (Vascular Accreditation, Location & Utilization Evaluation) Study examines the proportion of IAC accredited facilities providing vascular testing procedures nationally, and the geographic distribution and utilization of these facilities. The data set containing all facilities that billed Medicare for outpatient vascular testing services in 2011 (5% CMS Outpatient Limited Data Set (LDS) file) was examined, and locations of outpatient vascular testing facilities were obtained from the 2011 CMS/Medicare Provider of Services (POS) file. Of 13,462 total vascular testing facilities billing Medicare for vascular testing procedures in a 5% random Outpatient LDS for the US in 2011, 13% (n=1730) of facilities were IAC accredited. The percentage of IAC accredited vascular testing facilities in the LDS file varied significantly by US region, p<0.0001: 26%, 12%, 11%, and 7% for the Northeast, South, Midwest, and Western regions, respectively. Findings suggest that the proportion of outpatient vascular testing facilities that are IAC accredited is low and varies by region. Increasing the number of accredited vascular testing facilities to improve test quality is a hypothesis that should be tested in future research. © The Author(s) 2014.

  15. EVA Training and Development Facilities

    NASA Technical Reports Server (NTRS)

    Cupples, Scott

    2016-01-01

    Overview: Vast majority of US EVA (ExtraVehicular Activity) training and EVA hardware development occurs at JSC; EVA training facilities used to develop and refine procedures and improve skills; EVA hardware development facilities test hardware to evaluate performance and certify requirement compliance; Environmental chambers enable testing of hardware from as large as suits to as small as individual components in thermal vacuum conditions.

  16. Utilisation of real-scale renewable energy test facility for validation of generic wind turbine and wind power plant controller models

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zeni, Lorenzo; Hesselbæk, Bo; Bech, John

    This article presents an example of application of a modern test facility conceived for experiments regarding the integration of renewable energy in the power system. The capabilities of the test facility are used to validate dynamic simulation models of wind power plants and their controllers. The models are based on standard and generic blocks. The successful validation of events related to the control of active power (control phenomena in <10 Hz range, including frequency control and power oscillation damping) is described, demonstrating the capabilities of the test facility and drawing the track for future work and improvements.

  17. Improvements and Performance of the Fermilab Solenoid Test Facility

    DOE PAGES

    Orris, Darryl; Arnold, Don; Brandt, Jeffrey; ...

    2017-06-01

    Here, the Solenoid Test Facility at Fermilab was built using a large vacuum vessel for testing of conduction-cooled superconducting solenoid magnets, and was first used to determine the performance of the MICE Coupling Coil. The facility was modified recently to enable testing of solenoid magnets for the Mu2e experiment, which operate at much higher current than the Coupling Coil. One pair of low current conduction-cooled copper and NbTi leads was replaced with two pairs of 10 kA HTS leads cooled by heat exchange with liquid nitrogen and liquid helium. The new design, with additional control and monitoring capability, also providesmore » helium cooling of the superconducting magnet leads by conduction. A high current power supply with energy extraction was added, and several improvements to the quench protection and characterization system were made. Here we present details of these changes and report on performance results from a test of the Mu2e prototype Transport Solenoid (TS) module. Progress on additional improvements in preparation for production TS module testing will be presented.« less

  18. Improvements and Performance of the Fermilab Solenoid Test Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Orris, Darryl; Arnold, Don; Brandt, Jeffrey

    Here, the Solenoid Test Facility at Fermilab was built using a large vacuum vessel for testing of conduction-cooled superconducting solenoid magnets, and was first used to determine the performance of the MICE Coupling Coil. The facility was modified recently to enable testing of solenoid magnets for the Mu2e experiment, which operate at much higher current than the Coupling Coil. One pair of low current conduction-cooled copper and NbTi leads was replaced with two pairs of 10 kA HTS leads cooled by heat exchange with liquid nitrogen and liquid helium. The new design, with additional control and monitoring capability, also providesmore » helium cooling of the superconducting magnet leads by conduction. A high current power supply with energy extraction was added, and several improvements to the quench protection and characterization system were made. Here we present details of these changes and report on performance results from a test of the Mu2e prototype Transport Solenoid (TS) module. Progress on additional improvements in preparation for production TS module testing will be presented.« less

  19. Influence of computational fluid dynamics on experimental aerospace facilities: A fifteen year projection

    NASA Technical Reports Server (NTRS)

    1983-01-01

    An assessment was made of the impact of developments in computational fluid dynamics (CFD) on the traditional role of aerospace ground test facilities over the next fifteen years. With improvements in CFD and more powerful scientific computers projected over this period it is expected to have the capability to compute the flow over a complete aircraft at a unit cost three orders of magnitude lower than presently possible. Over the same period improvements in ground test facilities will progress by application of computational techniques including CFD to data acquisition, facility operational efficiency, and simulation of the light envelope; however, no dramatic change in unit cost is expected as greater efficiency will be countered by higher energy and labor costs.

  20. Evaluating the Emergency Notification Systems of the NASA White Sands Test

    NASA Technical Reports Server (NTRS)

    Chavez, Alfred Paul

    2004-01-01

    The problem was that the NASA Fire and Emergency Services did not know if the current emergency notification systems on the NASA White Sands Test Facility were appropriate for alerting the employees of an emergency. The purpose of this Applied Research Project was to determine if the current emergency notification systems of the White Sands Test Facility are appropriate for alerting the employees of an emergency. This was a descriptive research project. The research questions were: 1) What are similar facilities using to alert the employees of an emergency?; 2) Are the current emergency notification systems suitable for the community hazards on the NASA White Sands Test Facility?; 3) What is the NASA Fire and Emergency Services currently using to measure the effectiveness of the emergency notification systems?; and 4) What are the current training methods used to train personnel to the emergency notification systems at the NASA White Sands Test Facility? The procedures involved were to research other established facilities, research published material from credible sources, survey the facility to determine the facility perception of the emergency notification systems, and evaluate the operating elements of the established emergency notification systems for the facility. The results were that the current systems are suitable for the type of hazards the facility may endure. The emergency notification systems are tested frequently to ensure effectiveness in the event of an emergency. Personnel are trained and participate in a yearly drill to make certain personnel are educated on the established systems. The recommendations based on the results were to operationally improve the existing systems by developing and implementing one system that can overall notify the facility of a hazard. Existing procedures and training should also be improved to ensure that all personnel are educated on what to do when the emergency notification systems are activated.

  1. Electromagnetic Test-Facility characterization: an identification approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zicker, J.E.; Candy, J.V.

    The response of an object subjected to high energy, transient electromagnetic (EM) fields sometimes called electromagnetic pulses (EMP), is an important issue in the survivability of electronic systems (e.g., aircraft), especially when the field has been generated by a high altitude nuclear burst. The characterization of transient response information is a matter of national concern. In this report we discuss techniques to: (1) improve signal processing at a test facility; and (2) parameterize a particular object response. First, we discuss the application of identification-based signal processing techniques to improve signal levels at the Lawrence Livermore National Laboratory (LLNL) EM Transientmore » Test Facility. We identify models of test equipment and then use these models to deconvolve the input/output sequences for the object under test. A parametric model of the object is identified from this data. The model can be used to extrapolate the response to these threat level EMP. Also discussed is the development of a facility simulator (EMSIM) useful for experimental design and calibration and a deconvolution algorithm (DECONV) useful for removing probe effects from the measured data.« less

  2. Major improvements in the quality of malaria case-management under the "test and treat" policy in Kenya.

    PubMed

    Zurovac, Dejan; Githinji, Sophie; Memusi, Dorothy; Kigen, Samuel; Machini, Beatrice; Muturi, Alex; Otieno, Gabriel; Snow, Robert W; Nyandigisi, Andrew

    2014-01-01

    Monitoring implementation of the "test and treat" case-management policy for malaria is an important component of all malaria control programmes in Africa. Unfortunately, routine information systems are commonly deficient to provide necessary information. Using health facility surveys we monitored health systems readiness and malaria case-management practices prior to and following implementation of the 2010 "test and treat" policy in Kenya. Between 2010 and 2013 six national, cross-sectional, health facility surveys were undertaken. The number of facilities assessed ranged between 172 and 176, health workers interviewed between 216 and 237 and outpatient consultations for febrile patients evaluated between 1,208 and 2,408 across six surveys. Comparing baseline and the last survey results, all readiness indicators showed significant (p<0.005) improvements: availability of parasitological diagnosis (55.2% to 90.7%); RDT availability (7.5% to 69.8%); total artemether-lumefantrine (AL) stock-out (27.2% to 7.0%); stock-out of one or more AL packs (59.5% to 21.6%); training coverage (0 to 50.2%); guidelines access (0 to 58.1%) and supervision (17.9% to 30.8%). Testing increased by 34.0% (23.9% to 57.9%; p<0.001) while testing and treatment according to test result increased by 34.2% (15.7% to 49.9%; p<0.001). Treatment adherence for test positive patients improved from 83.3% to 90.3% (p = 0.138) and for test negative patients from 47.9% to 83.4% (p<0.001). Significant testing and treatment improvements were observed in children and adults. There was no difference in practices with respect to the type and result of malaria test (RDT vs microscopy). Of eight dosing, dispensing and counseling tasks, improvements were observed for four tasks. Overall AL use for febrile patients decreased from 63.5% to 35.6% (p<0.001). Major improvements in the implementation of "test and treat" policy were observed in Kenya. Some gaps towards universal targets still remained. Other countries facing similar needs and challenges may consider health facility surveys to monitor malaria case-management.

  3. Developments in Test Facility and Data Networking for the Altitude Test Stand at the John C. Stennis Space Center, MS - A General Overview

    NASA Technical Reports Server (NTRS)

    Hebert, Phillip W., Sr.

    2008-01-01

    May 2007, NASA's Constellation Program selected John C Stennis Space Center (SSC) near Waveland Mississippi as the site to construct an altitude test facility for the developmental and qualification testing of the Ares1 upper stage (US) engine. Test requirements born out of the Ares1 US propulsion system design necessitate exceptional Data Acquisition System (DAS) design solutions that support facility and propellant systems conditioning, test operations control and test data analysis. This paper reviews the new A3 Altitude Test Facility's DAS design requirements for real-time deterministic digital data, DAS technology enhancements, system trades, technology validation activities, and the current status of this system's new architecture. Also to be discussed will be current network technologies to improve data transfer.

  4. Recent "Ground Testing" Experiences in the National Full-Scale Aerodynamics Complex

    NASA Technical Reports Server (NTRS)

    Zell, Peter; Stich, Phil; Sverdrup, Jacobs; George, M. W. (Technical Monitor)

    2002-01-01

    The large test sections of the National Full-scale Aerodynamics Complex (NFAC) wind tunnels provide ideal controlled wind environments to test ground-based objects and vehicles. Though this facility was designed and provisioned primarily for aeronautical testing requirements, several experiments have been designed to utilize existing model mount structures to support "non-flying" systems. This presentation will discuss some of the ground-based testing capabilities of the facility and provide examples of groundbased tests conducted in the facility to date. It will also address some future work envisioned and solicit input from the SATA membership on ways to improve the service that NASA makes available to customers.

  5. Development of test methods for scale model simulation of aerial applications in the NASA Langley Vortex Research Facility. [agricultural aircraft

    NASA Technical Reports Server (NTRS)

    Jordan, F. L., Jr.

    1980-01-01

    As part of basic research to improve aerial applications technology, methods were developed at the Langley Vortex Research Facility to simulate and measure deposition patterns of aerially-applied sprays and granular materials by means of tests with small-scale models of agricultural aircraft and dynamically-scaled test particles. Interactions between the aircraft wake and the dispersed particles are being studied with the objective of modifying wake characteristics and dispersal techniques to increase swath width, improve deposition pattern uniformity, and minimize drift. The particle scaling analysis, test methods for particle dispersal from the model aircraft, visualization of particle trajectories, and measurement and computer analysis of test deposition patterns are described. An experimental validation of the scaling analysis and test results that indicate improved control of chemical drift by use of winglets are presented to demonstrate test methods.

  6. Using Facility Condition Assessments to Identify Actions Related to Infrastructure

    NASA Technical Reports Server (NTRS)

    Rubert, Kennedy F.

    2010-01-01

    To support cost effective, quality research it is essential that laboratory and testing facilities are maintained in a continuous and reliable state of availability at all times. NASA Langley Research Center (LaRC) and its maintenance contractor, Jacobs Technology, Inc. Research Operations, Maintenance, and Engineering (ROME) group, are in the process of implementing a combined Facility Condition Assessment (FCA) and Reliability Centered Maintenance (RCM) program to improve asset management and overall reliability of testing equipment in facilities such as wind tunnels. Specific areas are being identified for improvement, the deferred maintenance cost is being estimated, and priority is being assigned against facilities where conditions have been allowed to deteriorate. This assessment serves to assist in determining where to commit available funds on the Center. RCM methodologies are being reviewed and enhanced to assure that appropriate preventive, predictive, and facilities/equipment acceptance techniques are incorporated to prolong lifecycle availability and assure reliability at minimum cost. The results from the program have been favorable, better enabling LaRC to manage assets prudently.

  7. Association between health worker motivation and healthcare quality efforts in Ghana.

    PubMed

    Alhassan, Robert Kaba; Spieker, Nicole; van Ostenberg, Paul; Ogink, Alice; Nketiah-Amponsah, Edward; de Wit, Tobias F Rinke

    2013-08-14

    Ghana is one of the sub-Saharan African countries making significant progress towards universal access to quality healthcare. However, it remains a challenge to attain the 2015 targets for the health related Millennium Development Goals (MDGs) partly due to health sector human resource challenges including low staff motivation. This paper addresses indicators of health worker motivation and assesses associations with quality care and patient safety in Ghana. The aim is to identify interventions at the health worker level that contribute to quality improvement in healthcare facilities. The study is a baseline survey of health workers (n = 324) in 64 primary healthcare facilities in two regions in Ghana. Data collection involved quality care assessment using the SafeCare Essentials tool, the National Health Insurance Authority (NHIA) accreditation data and structured staff interviews on workplace motivating factors. The Spearman correlation test was conducted to test the hypothesis that the level of health worker motivation is associated with level of effort by primary healthcare facilities to improve quality care and patient safety. The quality care situation in health facilities was generally low, as determined by the SafeCare Essentials tool and NHIA data. The majority of facilities assessed did not have documented evidence of processes for continuous quality improvement and patient safety. Overall, staff motivation appeared low although workers in private facilities perceived better working conditions than workers in public facilities (P <0.05). Significant positive associations were found between staff satisfaction levels with working conditions and the clinic's effort towards quality improvement and patient safety (P <0.05). As part of efforts towards attainment of the health related MDGs in Ghana, more comprehensive staff motivation interventions should be integrated into quality improvement strategies especially in government-owned healthcare facilities where working conditions are perceived to be the worst.

  8. Future experimental needs to support applied aerodynamics - A transonic perspective

    NASA Technical Reports Server (NTRS)

    Gloss, Blair B.

    1992-01-01

    Advancements in facilities, test techniques, and instrumentation are needed to provide data required for the development of advanced aircraft and to verify computational methods. An industry survey of major users of wind tunnel facilities at Langley Research Center (LaRC) was recently carried out to determine future facility requirements, test techniques, and instrumentation requirements; results from this survey are reflected in this paper. In addition, areas related to transonic testing at LaRC which are either currently being developed or are recognized as needing improvements are discussed.

  9. Intersocietal Accreditation Commission Accreditation Status of Outpatient Cerebrovascular Testing Facilities Among Medicare Beneficiaries: The VALUE Study.

    PubMed

    Brown, Scott C; Wang, Kefeng; Dong, Chuanhui; Farrell, Mary Beth; Heller, Gary V; Gornik, Heather L; Hutchisson, Marge; Needleman, Laurence; Benenati, James F; Jaff, Michael R; Meier, George H; Perese, Susana; Bendick, Phillip; Hamburg, Naomi M; Lohr, Joann M; LaPerna, Lucy; Leers, Steven A; Lilly, Michael P; Tegeler, Charles; Katanick, Sandra L; Alexandrov, Andrei V; Siddiqui, Adnan H; Rundek, Tatjana

    2016-09-01

    Accreditation of cerebrovascular ultrasound laboratories by the Intersocietal Accreditation Commission (IAC) and equivalent organizations is supported by the Joint Commission certification of stroke centers. Limited information exists on the accreditation status and geographic distribution of cerebrovascular testing facilities in the United States. Our study objectives were to identify the proportion of IAC-accredited outpatient cerebrovascular testing facilities used by Medicare beneficiaries, describe their geographic distribution, and identify variations in cerebrovascular testing procedure types and volumes by accreditation status. As part of the VALUE (Vascular Accreditation, Location, and Utilization Evaluation) Study, we examined the proportion of IAC-accredited facilities that conducted cerebrovascular testing in a 5% Centers for Medicare and Medicaid Services random Outpatient Limited Data Set in 2011 and investigated their geographic distribution using geocoding. Among 7327 outpatient facilities billing Medicare for cerebrovascular testing, only 22% (1640) were IAC accredited. The proportion of IAC-accredited cerebrovascular testing facilities varied by region (χ(2)[3] = 177.1; P < .0001), with 29%, 15%, 13%, and 10% located in the Northeast, South, Midwest, and West, respectively. However, of the total number of cerebrovascular outpatient procedures conducted in 2011 (38,555), 40% (15,410) were conducted in IAC-accredited facilities. Most cerebrovascular testing procedures were carotid duplex, with 40% of them conducted in IAC-accredited facilities. The proportion of facilities conducting outpatient cerebrovascular testing accredited by the IAC is low and varies by region. The growing number of certified stroke centers should be accompanied by more accredited outpatient vascular testing facilities, which could potentially improve the quality of stroke care.

  10. Limited Effectiveness of a Skills and Drills Intervention to Improve Emergency Obstetric and Newborn Care in Karnataka, India: A Proof-of-Concept Study.

    PubMed

    Varghese, Beena; Krishnamurthy, Jayanna; Correia, Blaze; Panigrahi, Ruchika; Washington, Maryann; Ponnuswamy, Vinotha; Mony, Prem

    2016-12-23

    The majority of the maternal and perinatal deaths are preventable through improved emergency obstetric and newborn care at facilities. However, the quality of such care in India has significant gaps in terms of provider skills and in their preparedness to handle emergencies. We tested the feasibility, acceptability, and effectiveness of a "skills and drills" intervention, implemented between July 2013 and September 2014, to improve emergency obstetric and newborn care in the state of Karnataka, India. Emergency drills through role play, conducted every 2 months, combined with supportive supervision and a 2-day skills refresher session were delivered across 4 sub-district, secondary-level government facilities by an external team of obstetric and pediatric specialists and nurses. We evaluated the intervention through a quasi-experimental design with 4 intervention and 4 comparison facilities, using delivery case sheet reviews, pre- and post-knowledge tests among providers, objective structured clinical examinations (OSCEs), and qualitative in-depth interviews. Primary outcomes consisted of improved diagnosis and management of selected maternal and newborn complications (postpartum hemorrhage, pregnancy-induced hypertension, and birth asphyxia). Secondary outcomes included knowledge and skill levels of providers and acceptability and feasibility of the intervention. Knowledge scores among providers improved significantly in the intervention facilities; in obstetrics, average scores between the pre- and post-test increased from 49% to 57% (P=.006) and in newborn care, scores increased from 48% to 56% (P=.03). Knowledge scores in the comparison facilities were similar but did not improve significantly over time. Skill levels were significantly higher among providers in intervention facilities than comparison facilities (mean objective structured clinical examination scores for obstetric skills: 55% vs. 46%, respectively; for newborn skills: 58% vs. 48%, respectively; P<.001 for both obstetric and newborn), along with their confidence in managing complications. However, this did not result in significant differences in correct diagnosis and management of complications between intervention and comparison facilities. Shortage of trained nurses and doctors along with unavailability of a consistent supply chain was cited by most providers as major health systems barriers affecting provision of care. Improvements in knowledge, skills, and confidence levels of providers as a result of the skills and drills intervention was not sufficient to translate into improved diagnosis and management of maternal and newborn complications. System-level changes including adequate in-service training may also be necessary to improve maternal and newborn outcomes. © Varghese et al.

  11. Refurbishment and Automation of Thermal Vacuum Facilities at NASA/GSFC

    NASA Technical Reports Server (NTRS)

    Dunn, Jamie; Gomez, Carlos; Donohue, John; Johnson, Chris; Palmer, John; Sushon, Janet

    1999-01-01

    The thermal vacuum facilities located at the Goddard Space Flight Center (GSFC) have supported both manned and unmanned space flight since the 1960s. Of the eleven facilities, currently ten of the systems are scheduled for refurbishment or replacement as part of a five-year implementation. Expected return on investment includes the reduction in test schedules, improvements in safety of facility operations, and reduction in the personnel support required for a test. Additionally, GSFC will become a global resource renowned for expertise in thermal engineering, mechanical engineering, and for the automation of thermal vacuum facilities and tests. Automation of the thermal vacuum facilities includes the utilization of Programmable Logic Controllers (PLCs), the use of Supervisory Control and Data Acquisition (SCADA) systems, and the development of a centralized Test Data Management System. These components allow the computer control and automation of mechanical components such as valves and pumps. The project of refurbishment and automation began in 1996 and has resulted in complete computer control of one facility (Facility 281), and the integration of electronically controlled devices and PLCs in multiple others.

  12. Refurbishment and Automation of Thermal Vacuum Facilities at NASA/GSFC

    NASA Technical Reports Server (NTRS)

    Dunn, Jamie; Gomez, Carlos; Donohue, John; Johnson, Chris; Palmer, John; Sushon, Janet

    1998-01-01

    The thermal vacuum facilities located at the Goddard Space Flight Center (GSFC) have supported both manned and unmanned space flight since the 1960s. Of the eleven facilities, currently ten of the systems are scheduled for refurbishment or replacement as part of a five-year implementation. Expected return on investment includes the reduction in test schedules, improvements in safety of facility operations, and reduction in the personnel support required for a test. Additionally, GSFC will become a global resource renowned for expertise in thermal engineering, mechanical engineering, and for the automation of thermal vacuum facilities and tests. Automation of the thermal vacuum facilities includes the utilization of Programmable Logic Controllers (PLCs), the use of Supervisory Control and Data Acquisition (SCADA) systems, and the development of a centralized Test Data Management System. These components allow the computer control and automation of mechanical components such as valves and pumps. The project of refurbishment and automation began in 1996 and has resulted in complete computer control of one facility (Facility 281), and the integration of electronically controlled devices and PLCs in multiple others.

  13. The Ferrara hard X-ray facility for testing/calibrating hard X-ray focusing telescopes

    NASA Astrophysics Data System (ADS)

    Loffredo, Gianluca; Frontera, Filippo; Pellicciotta, Damiano; Pisa, Alessandro; Carassiti, Vito; Chiozzi, Stefano; Evangelisti, Federico; Landi, Luca; Melchiorri, Michele; Squerzanti, Stefano

    2005-12-01

    We will report on the current configuration of the X-ray facility of the University of Ferrara recently used to perform reflectivity tests of mosaic crystals and to calibrate the experiment JEM X aboard Integral. The facility is now located in the technological campus of the University of Ferrara in a new building (named LARIX laboratory= LARge Italian X-ray facility) that includes a tunnel 100 m long with, on the sides, two large experimental rooms. The facility is being improved for determining the optical axis of mosaic crystals in Laue configuration, for calibrating Laue lenses and hard X-ray mirror prototypes.

  14. Heavy Gas Conversion of the NASA Langley Transonic Dynamics Tunnel

    NASA Technical Reports Server (NTRS)

    Corliss, James M.; Cole, Stanley, R.

    1998-01-01

    The heavy gas test medium has recently been changed in the Transonic Dynamics Tunnel (TDT) at the NASA Langley Research Center. A NASA Construction of Facilities project has converted the TDT heavy gas from dichlorodifluoromethane (R12) to 1,1,1,2 tetrafluoroethane (R134a). The facility s heavy gas processing system was extensively modified to implement the conversion to R134a. Additional system modifications have improved operator interfaces, hardware reliability, and quality of the research data. The facility modifications included improvements to the heavy gas compressor and piping, the cryogenic heavy gas reclamation system, and the heavy gas control room. A series of wind tunnel characterization and calibration tests are underway. Results of the flow characterization tests show the TDT operating envelope in R134a to be very similar to the previous operating envelope in R12.

  15. Assessment of facility readiness and provider preparedness for dealing with postpartum haemorrhage and pre-eclampsia/eclampsia in public and private health facilities of northern Karnataka, India: a cross-sectional study.

    PubMed

    Jayanna, Krishnamurthy; Mony, Prem; B M, Ramesh; Thomas, Annamma; Gaikwad, Ajay; H L, Mohan; Blanchard, James F; Moses, Stephen; Avery, Lisa

    2014-09-04

    The maternal mortality ratio in India has been declining over the past decade, but remains unacceptably high at 212 per 100,000 live births. Postpartum haemorrhage (PPH) and pre- eclampsia/eclampsia contribute to 40% of all maternal deaths. We assessed facility readiness and provider preparedness to deal with these two maternal complications in public and private health facilities of northern Karnataka state, south India. We undertook a cross-sectional study of 131 primary health centres (PHCs) and 148 higher referral facilities (74 public and 74 private) in eight districts of the region. Facility infrastructure and providers' knowledge related to screening and management of complications were assessed using facility checklists and test cases, respectively. We also attempted an audit of case sheets to assess provider practice in the management of complications. Chi square tests were used for comparing proportions. 84.5% and 62.9% of all facilities had atleast one doctor and three nurses, respectively; only 13% of higher facilities had specialists. Magnesium sulphate, the drug of choice to control convulsions in eclampsia was available in 18% of PHCs, 48% of higher public facilities and 70% of private facilities. In response to the test case on eclampsia, 54.1% and 65.1% of providers would administer anti-hypertensives and magnesium sulphate, respectively; 24% would administer oxygen and only 18% would monitor for magnesium sulphate toxicity. For the test case on PPH, only 37.7% of the providers would assess for uterine tone, and 40% correctly defined early PPH. Specialists were better informed than the other cadres, and the differences were statistically significant. We experienced generally poor response rates for audits due to non-availability and non-maintenance of case sheets. Addressing gaps in facility readiness and provider competencies for emergency obstetric care, alongside improving coverage of institutional deliveries, is critical to improve maternal outcomes. It is necessary to strengthen providers' clinical and problem solving skills through capacity building initiatives beyond pre-service training, such as through onsite mentoring and supportive supervision programs. This should be backed by a health systems response to streamline staffing and supply chains in order to improve the quality of emergency obstetric care.

  16. Improving Large-Scale Testing Capability by Modifying the 40- by 80-ft Wind Tunnel

    NASA Technical Reports Server (NTRS)

    Mort, Kenneth W.; Soderman, Paul T.; Eckert, William T.

    1979-01-01

    Interagency studies conducted during the last several years have indicated the need to Improve full-scale testing capabilities. The studies showed that the most effective trade between test capability and facility cost was provided by re-powering the existing Ames Research Center 40- by 80-ft Wind Tunnel to Increase the maximum speed from about 100 m/s (200 knots) lo about 150 m/s (300 knots) and by adding a new 24- by 37-m (80- by 120-ft) test section powered for about a 50-m/s (100-knot) maximum speed. This paper reviews the design of the facility, a few or its capabilities, and some of its unique features.

  17. Restoration of the Hypersonic Tunnel Facility at NASA Glenn Research Center, Plum Brook Station

    NASA Technical Reports Server (NTRS)

    Woodling, Mark A.

    2000-01-01

    The NASA Glenn Research Center's Hypersonic Tunnel Facility (HTF), located at the Plum Brook Station in Sandusky, Ohio, is a non-vitiated, free-jet facility, capable of testing large-scale propulsion systems at Mach Numbers from 5 to 7. As a result of a component failure in September of 1996, a restoration project was initiated in mid- 1997 to repair the damage to the facility. Following the 2-1/2 year effort, the HTF has been returned to an operational condition. Significant repairs and operational improvements have been implemented in order to ensure facility reliability and personnel safety. As of January 2000, this unique, state-of-the-art facility was ready for integrated systems testing.

  18. New Acoustic Arena Qualified at NASA Glenn's Aero-Acoustic Propulsion Laboratory

    NASA Technical Reports Server (NTRS)

    Wnuk, Stephen P.

    2004-01-01

    A new acoustic arena has been qualified in the Aero-Acoustic Propulsion Laboratory (AAPL) at the NASA Glenn Research Center. This arena is outfitted specifically for conducting fan noise research with the Advanced Noise Control Fan (ANCF) test rig. It features moveable walls with large acoustic wedges (2 by 2 by 1 ft) that create an acoustic environment usable at frequencies as low as 250 Hz. The arena currently uses two dedicated microphone arrays to acquire fan inlet and exhaust far-field acoustic data. It was used successfully in fiscal year 2003 to complete three ANCF tests. It also allowed Glenn to improve the operational efficiency of the four test rigs at AAPL and provided greater flexibility to schedule testing. There were a number of technical challenges to overcome in bringing the new arena to fruition. The foremost challenge was conflicting acoustic requirements of four different rigs. It was simply impossible to construct a static arena anywhere in the facility without intolerably compromising the acoustic test environment of at least one of the test rigs. This problem was overcome by making the wall sections of the new arena movable. Thus, the arena can be reconfigured to meet the operational requirements of any particular rig under test. Other design challenges that were encountered and overcome included structural loads of the large wedges, personnel access requirements, equipment maintenance requirements, and typical time and budget constraints. The new acoustic arena improves operations at the AAPL facility in several significant ways. First, it improves productivity by allowing multiple rigs to operate simultaneously. Second, it improves research data quality by providing a unique test area within the facility that is optimal for conducting fan noise research. Lastly, it reduces labor and equipment costs by eliminating the periodic need to transport the ANCF into and out of the primary AAPL acoustic arena. The investment to design, fabricate, and install the new compact arena in fiscal year 2002 has paid dividends in fiscal year 2003 and will for many years to come. It has provided a dedicated, high-quality acoustic arena to support low-speed fan testing for ANCF while minimizing scheduling impacts and improving operational productivity in the AAPL facility.

  19. Radiation Challenges for Electronics in the Vision for Space Exploration

    NASA Technical Reports Server (NTRS)

    LaBel, Kenneth A.

    2006-01-01

    The slides present a brief snapshot discussing electronics and exploration-related challenges. Radiation effects have been the prime target, however, electronic parts reliability issues must also be considered. Modern electronics are designed with a 3-5 year lifetime. Upscreening does not improve reliability, merely determines inherent levels. Testing costs are driven by device complexity; they increase tester complexity, beam requirements, and facility choices. Commercial devices may improve performance, but are not cost panaceas. There is need for a more cost-effective access to high energy heavy ion facilities such as NSCL and NSRL. Costs for capable test equipment can run more than $1M for full testing.

  20. Effect of an Education Presentation On the Knowledge and Awareness of Urinary Tract Infection among Non-Licensed and Licensed Health Care Workers in Long-Term Care Facilities.

    PubMed

    Freeman-Jobson, Jennifer H; Rogers, Jamie L; Ward-Smith, Peggy

    2016-01-01

    This article presents the findings of a pre-test, post-test quality improvement project that describes the change in knowledge from prior to and following an evidence-based education presentation. The presentation addressed the clinical symptoms, diagnostic processes, interventions, and responsibilities of licensed and unlicensed health care workers employed in long-term care facilities related to prevention and detection of non-catheter-related urinary tract infections. Results indicate that the education presentation improved knowledge in specific.

  1. Revalidation of the NASA Ames 11-by 11-Foot Transonic Wind Tunnel with a Commercial Airplane Model

    NASA Technical Reports Server (NTRS)

    Kmak, Frank J.; Hudgins, M.; Hergert, D.; George, Michael W. (Technical Monitor)

    2001-01-01

    The 11-By 11-Foot Transonic leg of the Unitary Plan Wind Tunnel (UPWT) was modernized to improve tunnel performance, capability, productivity, and reliability. Wind tunnel tests to demonstrate the readiness of the tunnel for a return to production operations included an Integrated Systems Test (IST), calibration tests, and airplane validation tests. One of the two validation tests was a 0.037-scale Boeing 777 model that was previously tested in the 11-By 11-Foot tunnel in 1991. The objective of the validation tests was to compare pre-modernization and post-modernization results from the same airplane model in order to substantiate the operational readiness of the facility. Evaluation of within-test, test-to-test, and tunnel-to-tunnel data repeatability were made to study the effects of the tunnel modifications. Tunnel productivity was also evaluated to determine the readiness of the facility for production operations. The operation of the facility, including model installation, tunnel operations, and the performance of tunnel systems, was observed and facility deficiency findings generated. The data repeatability studies and tunnel-to-tunnel comparisons demonstrated outstanding data repeatability and a high overall level of data quality. Despite some operational and facility problems, the validation test was successful in demonstrating the readiness of the facility to perform production airplane wind tunnel%, tests.

  2. Variations in pretransfusion practices.

    PubMed

    Padget, B J; Hannon, J L

    2003-01-01

    A variety of pretransfusion tests have been developed to improve the safety and effectiveness of transfusion. Recently, a number of traditional tests have been shown to offer limited clinical benefit and have been eliminated in many facilities. A survey of pretransfusion test practices was distributed to 116 hospital transfusion services. Routine test practices and facility size were analyzed. Ninety-one responses were received. Many smaller laboratories include tests such as anti-A,B, an autocontrol, and DAT, and immediate spin and 37 degrees Celsius microscopic readings. Nine percent never perform an Rh control with anti-D typing on patient samples. Various antibody screening and crossmatch methods are utilized. Individual laboratory test practices should be periodically assessed to ensure that they comply with standards, represent the recognized best practice, and are cost-effective. The survey responses indicate that many laboratories perform tests that are not necessary or cost-effective. These facilities should review their processes to determine which tests contribute to transfusion safety. Smaller facilities may be reluctant to change or lack the expertise necessary for this decision making and often continue to perform tests that have been eliminated in larger facilities. Consultation with larger hospital transfusion services may provide guidance for this change.

  3. Construction of the Propulsion Systems Laboratory No. 1 and 2

    NASA Image and Video Library

    1951-01-21

    Construction of the Propulsion Systems Laboratory No. 1 and 2 at the National Advisory Committee for Aeronautics (NACA) Lewis Flight Propulsion Laboratory. When it began operation in late 1952, the Propulsion Systems Laboratory was the NACA’s most powerful facility for testing full-scale engines at simulated flight altitudes. The facility contained two altitude simulating test chambers which were a technological combination of the static sea-level test stands and the complex Altitude Wind Tunnel, which recreated actual flight conditions on a larger scale. NACA Lewis began designing the new facility in 1947 as part of a comprehensive plan to improve the altitude testing capabilities across the lab. The exhaust, refrigeration, and combustion air systems from all the major test facilities were linked. In this way, different facilities could be used to complement the capabilities of one another. Propulsion Systems Laboratory construction began in late summer 1949 with the installation of an overhead exhaust pipe connecting the facility to the Altitude Wind Tunnel and Engine Research Building. The large test section pieces arriving in early 1951, when this photograph was taken. The two primary coolers for the altitude exhaust are in place within the framework near the center of the photograph.

  4. Refurbishment and Automation of the Thermal/Vacuum Facilities at the Goddard Space Flight Center

    NASA Technical Reports Server (NTRS)

    Donohue, John T.; Johnson, Chris; Ogden, Rick; Sushon, Janet

    1998-01-01

    The thermal/vacuum facilities located at the Goddard Space Flight Center (GSFC) have supported both manned and unmanned space flight since the 1960s. Of the 11 facilities, currently 10 of the systems are scheduled for refurbishment and/or replacement as part of a 5-year implementation. Expected return on investment includes the reduction in test schedules, improvements in the safety of facility operations, reduction in the complexity of a test and the reduction in personnel support required for a test. Additionally, GSFC will become a global resource renowned for expertise in thermal engineering, mechanical engineering and for the automation of thermal/vacuum facilities and thermal/vacuum tests. Automation of the thermal/vacuum facilities includes the utilization of Programmable Logic Controllers (PLCs) and the use of Supervisory Control and Data Acquisition (SCADA) systems. These components allow the computer control and automation of mechanical components such as valves and pumps. In some cases, the chamber and chamber shroud require complete replacement while others require only mechanical component retrofit or replacement. The project of refurbishment and automation began in 1996 and has resulted in the computer control of one Facility (Facility #225) and the integration of electronically controlled devices and PLCs within several other facilities. Facility 225 has been successfully controlled by PLC and SCADA for over one year. Insignificant anomalies have occurred and were resolved with minimal impact to testing and operations. The amount of work remaining to be performed will occur over the next four to five years. Fiscal year 1998 includes the complete refurbishment of one facility, computer control of the thermal systems in two facilities, implementation of SCADA and PLC systems to support multiple facilities and the implementation of a Database server to allow efficient test management and data analysis.

  5. The New Heavy Gas Testing Capability in the NASA Langley Transonic Dynamics Tunnel

    NASA Technical Reports Server (NTRS)

    Cole, Stanley R.; Rivera, Jose A., Jr.

    1997-01-01

    The NASA Langley Transonic Dynamics Tunnel (TDT) has provided a unique capability for aeroelastic testing for over thirty-five years. The facility has a rich history of significant contributions to the design of many United States commercial transports and military aircraft. The facility has many features which contribute to its uniqueness for aeroelasticity testing; however, perhaps the most important facility capability is the use of a heavy gas test medium to achieve higher test densities. Higher test medium densities substantially improve model building requirements and therefore simplify the fabrication process for building aeroelastically scaled wind-tunnel models. The heavy gas also provides other testing benefits, including reduction in the power requirements to operate the facility during testing. Unfortunately, the use of the original heavy gas has been curtailed due to environmental concerns. A new gas, referred to as R-134a, has been identified as a suitable replacement for the former TDT heavy gas. The TDT is currently undergoing a facility upgrade to allow testing in R-134a heavy gas. This replacement gas will result in an operational test envelope, model scaling advantages, and general testing capabilities similar to those available with the former TDT heavy gas. As such, the TDT is expected to remain a viable facility for aeroelasticity research and aircraft dynamic clearance testing well into the 21st century. This paper describes the anticipated advantages and facility calibration plans for the new heavy gas and briefly reviews several past test programs that exemplify the possible benefits of heavy gas testing.

  6. Recent Cycle Time Reduction at Langley Research Center

    NASA Technical Reports Server (NTRS)

    Kegelman, Jerome T.

    2000-01-01

    The NASA Langley Research Center (LaRC) has been engaged in an effort to reduce wind tunnel test cycle time in support of Agency goals and to satisfy the wind tunnel testing needs of the commercial and military aerospace communities. LaRC has established the Wind Tunnel Enterprise (WTE), with goals of reducing wind tunnel test cycle time by an order of magnitude by 2002, and by two orders of magnitude by 2010. The WTE also plans to meet customer expectations for schedule integrity, as well as data accuracy and quality assurance. The WTE has made progress towards these goals over the last year with a focused effort on technological developments balanced by attention to process improvements. This paper presents a summary of several of the WTE activities over the last year that are related to test cycle time reductions at the Center. Reducing wind tunnel test cycle time, defined here as the time between the freezing of loft lines and delivery of test data, requires that the relationship between high productivity and data quality assurance be considered. The efforts have focused on all of the drivers for test cycle time reduction, including process centered improvements, facility upgrades, technological improvements to enhance facility readiness and productivity, as well as advanced measurement techniques. The application of internet tools and computer modeling of facilities to allow a virtual presence of the customer team is also presented.

  7. Association between health worker motivation and healthcare quality efforts in Ghana

    PubMed Central

    2013-01-01

    Background Ghana is one of the sub-Saharan African countries making significant progress towards universal access to quality healthcare. However, it remains a challenge to attain the 2015 targets for the health related Millennium Development Goals (MDGs) partly due to health sector human resource challenges including low staff motivation. Purpose This paper addresses indicators of health worker motivation and assesses associations with quality care and patient safety in Ghana. The aim is to identify interventions at the health worker level that contribute to quality improvement in healthcare facilities. Methods The study is a baseline survey of health workers (n = 324) in 64 primary healthcare facilities in two regions in Ghana. Data collection involved quality care assessment using the SafeCare Essentials tool, the National Health Insurance Authority (NHIA) accreditation data and structured staff interviews on workplace motivating factors. The Spearman correlation test was conducted to test the hypothesis that the level of health worker motivation is associated with level of effort by primary healthcare facilities to improve quality care and patient safety. Results The quality care situation in health facilities was generally low, as determined by the SafeCare Essentials tool and NHIA data. The majority of facilities assessed did not have documented evidence of processes for continuous quality improvement and patient safety. Overall, staff motivation appeared low although workers in private facilities perceived better working conditions than workers in public facilities (P <0.05). Significant positive associations were found between staff satisfaction levels with working conditions and the clinic’s effort towards quality improvement and patient safety (P <0.05). Conclusion As part of efforts towards attainment of the health related MDGs in Ghana, more comprehensive staff motivation interventions should be integrated into quality improvement strategies especially in government-owned healthcare facilities where working conditions are perceived to be the worst. PMID:23945073

  8. Arc-Heater Facility for Hot Hydrogen Exposure of Nuclear Thermal Rocket Materials

    NASA Technical Reports Server (NTRS)

    Litchford, Ron J.; Foote, John P.; Wang,Ten-See; Hickman, Robert; Panda, Binayak; Dobson, Chris; Osborne, Robin; Clifton, Scooter

    2006-01-01

    A hyper-thermal environment simulator is described for hot hydrogen exposure of nuclear thermal rocket material specimens and component development. This newly established testing capability uses a high-power, multi-gas, segmented arc-heater to produce high-temperature pressurized hydrogen flows representative of practical reactor core environments and is intended to serve. as a low cost test facility for the purpose of investigating and characterizing candidate fueUstructura1 materials and improving associated processing/fabrication techniques. Design and development efforts are thoroughly summarized, including thermal hydraulics analysis and simulation results, and facility operating characteristics are reported, as determined from a series of baseline performance mapping tests.

  9. Using Plates and Trays with MyPlate Images to Encourage Healthy Food Choices: A Pilot Study at Military Dining Facilities

    DTIC Science & Technology

    dairy consumption . Future research should investigate the effectiveness of the MyPlate intervention for improving diet quality and nutrition knowledge in larger military dining facilities at different locations....introduced the new food labeling system. Dietary intake of facility patrons was measured during 12 lunch meals using the food photography method. Repeated...measures ANOVA, one-way ANOVA, paired t-test, and McNemars test were used. Results: Dairy consumption increased from baseline to intervention (0.50.4

  10. SNS Cryogenic Test Facility Kinney Vacuum Pump Commissioning and Operation at 2 K

    NASA Astrophysics Data System (ADS)

    DeGraff, B.; Howell, M.; Kim, S.; Neustadt, T.

    2017-12-01

    The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) has built and commissioned an independent Cryogenic Test Facility (CTF) in support of testing in the Radio-frequency Test Facility (RFTF). Superconducting Radio-frequency Cavity (SRF) testing was initially conducted with the CTF cold box at 4.5 K. A Kinney vacuum pump skid consisting of a roots blower with a liquid ring backing pump was recently added to the CTF system to provide testing capabilities at 2 K. System design, pump refurbishment and installation of the Kinney pump will be presented. During the commissioning and initial testing period with the Kinney pump, several barriers to achieve reliable operation were experienced. Details of these lessons learned and improvements to skid operations will be presented. Pump capacity data will also be presented.

  11. SNS Cryogenic Test Facility Kinney Vacuum Pump Commissioning and Operation at 2 K

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Degraff, Brian D.; Howell, Matthew P.; Kim, Sang-Ho

    The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) has built and commissioned an independent Cryogenic Test Facility (CTF) in support of testing in the Radio-frequency Test Facility (RFTF). Superconducting Radio-frequency Cavity (SRF) testing was initially conducted with the CTF cold box at 4.5 K. A Kinney vacuum pump skid consisting of a roots blower with a liquid ring backing pump was recently added to the CTF system to provide testing capabilities at 2 K. System design, pump refurbishment and installation of the Kinney pump will be presented. During the commissioning and initial testing period with the Kinneymore » pump, several barriers to achieve reliable operation were experienced. Details of these lessons learned and improvements to skid operations will be presented. Pump capacity data will also be presented.« less

  12. Effect of Community Engagement Interventions on Patient Safety and Risk Reduction Efforts in Primary Health Facilities: Evidence from Ghana

    PubMed Central

    Alhassan, Robert Kaba; Nketiah-Amponsah, Edward; Spieker, Nicole; Arhinful, Daniel Kojo; Ogink, Alice; van Ostenberg, Paul; Rinke de Wit, Tobias F.

    2015-01-01

    Background Patient safety and quality care remain major challenges to Ghana’s healthcare system. Like many health systems in Africa, this is largely because demand for healthcare is outstripping available human and material resource capacity of healthcare facilities and new investment is insufficient. In the light of these demand and supply constraints, systematic community engagement (SCE) in healthcare quality assessment can be a feasible and cost effective option to augment existing quality improvement interventions. SCE entails structured use of existing community groups to assess healthcare quality in health facilities. Identified quality gaps are discussed with healthcare providers, improvements identified and rewards provided if the quality gaps are closed. Purpose This paper evaluates whether or not SCE, through the assessment of health service quality, improves patient safety and risk reduction efforts by staff in healthcare facilities. Methods A randomized control trail was conducted in 64 primary healthcare facilities in the Greater Accra and Western regions of Ghana. Patient risk assessments were conducted in 32 randomly assigned intervention and control facilities. Multivariate multiple regression test was used to determine effect of the SCE interventions on staff efforts towards reducing patient risk. Spearman correlation test was used to ascertain associations between types of community groups engaged and risk assessment scores of healthcare facilities. Findings Clinic staff efforts towards increasing patient safety and reducing risk improved significantly in intervention facilities especially in the areas of leadership/accountability (Coef. = 10.4, p<0.05) and staff competencies (Coef. = 7.1, p<0.05). Improvement in service utilization and health resources could not be attributed to the interventions because these were outside the control of the study and might have been influenced by institutional or national level developments between the baseline and follow-up period. Community groups that were gender balanced, religious/faith-based, and had structured leadership appeared to be better options for effective SCE in healthcare quality assessment. Conclusion Community engagement in healthcare quality assessment is a feasible client-centered quality improvement option that should be discussed for possible scale-up in Ghana and other resource poor countries in Africa. PMID:26619143

  13. Effect of Community Engagement Interventions on Patient Safety and Risk Reduction Efforts in Primary Health Facilities: Evidence from Ghana.

    PubMed

    Alhassan, Robert Kaba; Nketiah-Amponsah, Edward; Spieker, Nicole; Arhinful, Daniel Kojo; Ogink, Alice; van Ostenberg, Paul; Rinke de Wit, Tobias F

    2015-01-01

    Patient safety and quality care remain major challenges to Ghana's healthcare system. Like many health systems in Africa, this is largely because demand for healthcare is outstripping available human and material resource capacity of healthcare facilities and new investment is insufficient. In the light of these demand and supply constraints, systematic community engagement (SCE) in healthcare quality assessment can be a feasible and cost effective option to augment existing quality improvement interventions. SCE entails structured use of existing community groups to assess healthcare quality in health facilities. Identified quality gaps are discussed with healthcare providers, improvements identified and rewards provided if the quality gaps are closed. This paper evaluates whether or not SCE, through the assessment of health service quality, improves patient safety and risk reduction efforts by staff in healthcare facilities. A randomized control trail was conducted in 64 primary healthcare facilities in the Greater Accra and Western regions of Ghana. Patient risk assessments were conducted in 32 randomly assigned intervention and control facilities. Multivariate multiple regression test was used to determine effect of the SCE interventions on staff efforts towards reducing patient risk. Spearman correlation test was used to ascertain associations between types of community groups engaged and risk assessment scores of healthcare facilities. Clinic staff efforts towards increasing patient safety and reducing risk improved significantly in intervention facilities especially in the areas of leadership/accountability (Coef. = 10.4, p<0.05) and staff competencies (Coef. = 7.1, p<0.05). Improvement in service utilization and health resources could not be attributed to the interventions because these were outside the control of the study and might have been influenced by institutional or national level developments between the baseline and follow-up period. Community groups that were gender balanced, religious/faith-based, and had structured leadership appeared to be better options for effective SCE in healthcare quality assessment. Community engagement in healthcare quality assessment is a feasible client-centered quality improvement option that should be discussed for possible scale-up in Ghana and other resource poor countries in Africa.

  14. Impact Landing Dynamics Facility Crash Test

    NASA Image and Video Library

    1975-08-03

    Photographed on: 08/03/75. -- By 1972 the Lunar Landing Research Facility was no longer in use for its original purpose. The 400-foot high structure was swiftly modified to allow engineers to study the dynamics of aircraft crashes. "The Impact Dynamics Research Facility is used to conduct crash testing of full-scale aircraft under controlled conditions. The aircraft are swung by cables from an A-frame structure that is approximately 400 ft. long and 230 foot high. The impact runway can be modified to simulate other grand crash environments, such as packed dirt, to meet a specific test requirement." "In 1972, NASA and the FAA embarked on a cooperative effort to develop technology for improved crashworthiness and passenger survivability in general aviation aircraft with little or no increase in weight and acceptable cost. Since then, NASA has "crashed" dozens of GA aircraft by using the lunar excursion module (LEM) facility originally built for the Apollo program." This photograph shows Crash Test No. 7. Crash Test: Test #7

  15. Status of the National Transonic Facility Characterization

    NASA Technical Reports Server (NTRS)

    Bobbitt, C., Jr.; Everhart, J.

    2001-01-01

    This paper describes the current activities at the National Transonic Facility to document the test-section flow and to support tunnel improvements. The paper is divided into sections on the tunnel calibration, flow quality measurements, data quality assurance, and implementation of wall interference corrections.

  16. Using mobile phone text messaging for malaria surveillance in rural Kenya

    PubMed Central

    2014-01-01

    Background Effective surveillance systems are required to track malaria testing and treatment practices. A 26-week study “SMS for Life” was piloted in five rural districts of Kenya to examine whether SMS reported surveillance data could ensure real-time visibility of accurate data and their use by district managers to impact on malaria case-management. Methods Health workers from 87 public health facilities used their personal mobile phones to send a weekly structured SMS text message reporting the counts of four basic surveillance data elements to a web-based system accessed by district managers. Longitudinal monitoring of SMS reported data through the web-based system and two rounds of cross-sectional health facility surveys were done to validate accuracy of data. Results Mean response rates were 96% with 87% of facilities reporting on time. Fifty-eight per cent of surveillance data parameters were accurately reported. Overall mean testing rates were 37% with minor weekly variations ranging from 32 to 45%. Overall test positivity rate was 24% (weekly range: 17-37%). Ratio of anti-malarial treatments to test positive cases was 1.7:1 (weekly range: 1.3:1–2.2:1). District specific trends showed fluctuating patterns in testing rates without notable improvement over time but the ratio of anti-malarial treatments to test positive cases improved over short periods of time in three out of five districts. Conclusions The study demonstrated the feasibility of using simple mobile phone text messages to transmit timely surveillance data from peripheral health facilities to higher levels. However, accuracy of data reported was suboptimal. Future work should focus on improving quality of SMS reported surveillance data. PMID:24642130

  17. Space simulation facilities providing a stable thermal vacuum facility

    NASA Technical Reports Server (NTRS)

    Tellalian, Martin L.

    1990-01-01

    CBI has recently constructed the Intermediate Thermal Vacuum Facility. Built as a corporate facility, the installation will first be used on the Boost Surveillance and Tracking System (BSTS) program. It will also be used to develop and test other sensor systems. The horizontal chamber has a horseshoe shaped cross section and is supported on pneumatic isolators for vibration isolation. The chamber structure was designed to meet stability and stiffness requirements. The design process included measurement of the ambient ground vibrations, analysis of various foundation test article support configurations, design and analysis of the chamber shell and modal testing of the chamber shell. A detailed 3-D finite element analysis was made in the design stage to predict the lowest three natural frequencies and mode shapes and to identify local vibrating components. The design process is described and the results are compared of the finite element analysis to the results of the field modal testing and analysis for the 3 lowest natural frequencies and mode shapes. Concepts are also presented for stiffening large steel structures along with methods to improve test article stability in large space simulation facilities.

  18. Assessment of screening practices for gestational hyperglycaemia in public health facilities: a descriptive study in bangalore, India.

    PubMed

    Babu, Giridhara R; Tejaswi, B; Kalavathi, M; Vatsala, G M; Murthy, G V S; Kinra, Sanjay; Neelon, Sara E Benjamin

    2015-02-20

    Screening and timely treatment of gestational hyperglycaemia (GH) is proved to be beneficial and improves maternal and foetal health outcomes. To understand screening practices, we explored the knowledge and perceptions of doctors working in public health facilities in Bangalore, India. We also studied participation factors by examining whether undergoing glucose estimation tests affects morning sickness in pregnant women. We aimed to understand the screening practices and knowledge of doctors. A semi-structured questionnaire was self-administered by the 50 participant doctors, selected from the sampling frame comprising of all the doctors working in public health facilities. We included 105 pregnant women for baseline assessment, in whom a well-structured questionnaire was used. We reported that gestational diabetes mellitus (GDM) screening was done in nearly all the health centres (96%). However, only 12% of the doctors could provide all components of GDM diagnosis and management correctly and 46% would diagnose by using a random blood glucose test. A majority (92%) of the doctors had poor knowledge (68%) about the cut-off values of glucose tests. More than 80% of pregnant women experienced some discomfort mostly due to rapid ingestion glucose in short span of time. Our study established that screening for GH is done in most public health facilities. Nonetheless, knowledge of doctors on the glucose tests and their interpretation needs improvement. Re-orientation trainings of the doctors can improve their knowledge and thereby can efficiently screen for GH. Further, adequate planning prior to the tests can aid successful completion of them. Significance for public healthRising burden of hyperglycaemia in pregnancy is a cause for concern and is associated with short and long term deleterious consequences for mother and offspring. Hence, there is an urgent need to explore the screening practices for gestational hyperglycaemia (GH). The current study considers patient and doctors' perspectives regarding GH screening. The results from our study indicate several issues during screening of gestational hyperglycaemia in public health facilities in Bangalore, India. These included low awareness levels among doctors, lack of standard operating procedures and lack of adequate care and attention provided to pregnant women. Re-orientation trainings of the doctors within public health facilities can improve their knowledge and thereby can efficiently screen for GH. Further, adequate planning and preparation of the patient prior to the tests can help ensure successful completion of the tests. The findings of the study are comparable with the practices of public health hospitals in India.

  19. Evaluating Fidelity to a Modified NIATx Process Improvement Strategy for Improving HIV Services in Correctional Facilities.

    PubMed

    Pankow, Jennifer; Willett, Jennifer; Yang, Yang; Swan, Holly; Dembo, Richard; Burdon, William M; Patterson, Yvonne; Pearson, Frank S; Belenko, Steven; Frisman, Linda K

    2018-04-01

    In a study aimed at improving the quality of HIV services for inmates, an organizational process improvement strategy using change teams was tested in 14 correctional facilities in 8 US states and Puerto Rico. Data to examine fidelity to the process improvement strategy consisted of quantitative ratings of the structural and process components of the strategy and qualitative notes that explicate challenges in maintaining fidelity to the strategy. Fidelity challenges included (1) lack of communication and leadership within change teams, (2) instability in team membership, and (3) issues with data utilization in decision-making to implement improvements to services delivery.

  20. Status of the National Transonic Facility Characterization (Invited)

    NASA Technical Reports Server (NTRS)

    Bobbitt, C., Jr.; Everhart, J.

    2001-01-01

    This paper describes the current activities at the National Transonic Facility to document the test-section flow and to support tunnel improvements. The paper is divided into sections on the tunnel calibration, flow quality measurements, data quality assurance, and implementation of wall interference corrections.

  1. NASA AETC Test Technology Subproject

    NASA Technical Reports Server (NTRS)

    Bell, James

    2017-01-01

    Funds directed to improve measurement capabilities (pressure, force, flow, and temperature), test techniques and processes, and develop technologies critical to meeting NASA research needs and applicable to a multitude of facilities. Primarily works by funding small ($40K - $400K) tasks which result in a demonstration or initial capability of a new technology in an AETC facility.TT research and development tasks are generally TRL 3-6; they should be things which work in small scale or lab environments but need further development for use in production facilities.TT differs from CA in its focus on smaller-scale tasks and on instrumentation. Technologies developed by TT may become CA projects in order be fully realized within a facility.

  2. Household trends in access to improved water sources and sanitation facilities in Vietnam and associated factors: findings from the Multiple Indicator Cluster Surveys, 2000-2011.

    PubMed

    Tuyet-Hanh, Tran Thi; Lee, Jong-Koo; Oh, Juhwan; Van Minh, Hoang; Ou Lee, Chul; Hoan, Le Thi; Nam, You-Seon; Long, Tran Khanh

    2016-01-01

    Despite progress made by the Millennium Development Goal (MDG) number 7.C, Vietnam still faces challenges with regard to the provision of access to safe drinking water and basic sanitation. This paper describes household trends in access to improved water sources and sanitation facilities separately, and analyses factors associated with access to improved water sources and sanitation facilities in combination. Secondary data from the Vietnam Multiple Indicator Cluster Survey in 2000, 2006, and 2011 were analyzed. Descriptive statistics and tests of significance describe trends over time in access to water and sanitation by location, demographic and socio-economic factors. Binary logistic regressions (2000, 2006, and 2011) describe associations between access to water and sanitation, and geographic, demographic, and socio-economic factors. There have been some outstanding developments in access to improved water sources and sanitation facilities from 2000 to 2011. In 2011, the proportion of households with access to improved water sources and sanitation facilities reached 90% and 77%, respectively, meeting the 2015 MDG targets for safe drinking water and basic sanitation set at 88% and 75%, respectively. However, despite these achievements, in 2011, only 74% of households overall had access to combined improved drinking water and sanitation facilities. There were also stark differences between regions. In 2011, only 47% of households had access to both improved water and sanitation facilities in the Mekong River Delta compared with 94% in the Red River Delta. In 2011, households in urban compared to rural areas were more than twice as likely (odds ratio [OR]: 2.2; 95% confidence interval [CI]: 1.9-2.5) to have access to improved water and sanitation facilities in combination, and households in the highest compared with the lowest wealth quintile were over 40 times more likely (OR: 42.3; 95% CI: 29.8-60.0). More efforts are required to increase household access to both improved water and sanitation facilities in the Mekong River Delta, South East and Central Highlands regions of Vietnam. There is also a need to address socio-economic factors associated with inadequate access to improved sanitation facilities.

  3. Optimizing Facility Configurations and Operating Conditions for Improved Performance in the NASA Ames 24 Inch Shock Tube

    NASA Technical Reports Server (NTRS)

    Bogdanoff, David W.; Cruden, Brett A.

    2016-01-01

    The Ames Electric Arc Shock Tube (EAST) is a shock tube wherein the driver gas can be heated by an electric arc discharge. The electrical energy is stored in a 1.2 MJ capacitor bank. Four inch and 24 inch diameter driven tubes are available. The facility is described and the need for testing in the 24 inch tube to better simulate low density NASA mission profiles is discussed. Three test entries, 53, 53B and 59, are discussed. Tests are done with air or Mars gas (95.7% CO2/2.7% N2/1.6% Ar) at pressures of 0.01 to 0.14 Torr. Velocities spanned 6.3-9.2 km/s, with a nominal center of 7 km/s. Many facility configurations are studied in an effort to improve data quality. Various driver and driven tube configurations and the use of a buffer section between the driver and the driven tube are studied. Diagnostics include test times, time histories of the shock light pulses and tilts of the shock wave off the plane normal to the tube axis. The report will detail the results of the various trials, give the best configuration/operating conditions found to date and provide recommendations for further improvements. Finally, diaphragm performance is discussed.

  4. Scale Model Icing Research Tunnel

    NASA Technical Reports Server (NTRS)

    Canacci, Victor A.

    1997-01-01

    NASA Lewis Research Center's Icing Research Tunnel (IRT) is the world's largest refrigerated wind tunnel and one of only three icing wind tunnel facilities in the United States. The IRT was constructed in the 1940's and has been operated continually since it was built. In this facility, natural icing conditions are duplicated to test the effects of inflight icing on actual aircraft components as well as on models of airplanes and helicopters. IRT tests have been used successfully to reduce flight test hours for the certification of ice-detection instrumentation and ice protection systems. To ensure that the IRT will remain the world's premier icing facility well into the next century, Lewis is making some renovations and is planning others. These improvements include modernizing the control room, replacing the fan blades with new ones to increase the test section maximum velocity to 430 mph, installing new spray bars to increase the size and uniformity of the artificial icing cloud, and replacing the facility heat exchanger. Most of the improvements will have a first-order effect on the IRT's airflow quality. To help us understand these effects and evaluate potential improvements to the flow characteristics of the IRT, we built a modular 1/10th-scale aerodynamic model of the facility. This closed-loop scale-model pilot tunnel was fabricated onsite in the various shops of Lewis' Fabrication Support Division. The tunnel's rectangular sections are composed of acrylic walls supported by an aluminum angle framework. Its turning vanes are made of tubing machined to the contour of the IRT turning vanes. The fan leg of the tunnel, which transitions from rectangular to circular and back to rectangular cross sections, is fabricated of fiberglass sections. The contraction section of the tunnel is constructed from sheet aluminum. A 12-bladed aluminum fan is coupled to a turbine powered by high-pressure air capable of driving the maximum test section velocity to 550 ft/sec (Mach 0.45). The air turbine and instrumentation are housed inside a fiberglass nacelle. Total and static pressure measurements can be taken around the loop, and velocity and flow angularity measurements can be taken with hot-wire and five-hole probes at specific locations. The Scale Model Icing Research Tunnel (SMIRT) is undergoing checkout tests to determine how its airflow characteristics compare with the IRT. Near-term uses for this scale-model tunnel include determining the aerodynamic effects of replacing the 52-yearold W-shaped heat exchanger with a flat-faced heat exchanger. SMIRT is an integral part of the improvements planned for the IRT because testing the proposed IRT improvements in a scale-model tunnel will lower costs and improve productivity.

  5. A survey of experiments and experimental facilities for active control of flexible structures

    NASA Technical Reports Server (NTRS)

    Sparks, Dean W., Jr.; Horner, Garnett C.; Juang, Jer-Nan; Klose, Gerhard

    1989-01-01

    A brief survey of large space structure control related experiments and facilities was presented. This survey covered experiments performed before and up to 1982, and those of the present period (1982-...). Finally, the future planned experiments and facilities in support of the control-structure interaction (CSI) program were reported. It was stated that new, improved ground test facilities are needed to verify the new CSI design techniques that will allow future space structures to perform planned NASA missions.

  6. A standards-based approach to quality improvement for HIV services at Zambia Defence Force facilities: results and lessons learned.

    PubMed

    Kols, Adrienne; Kim, Young-Mi; Bazant, Eva; Necochea, Edgar; Banda, Joseph; Stender, Stacie

    2015-07-01

    The Zambia Defence Force adopted the Standards-Based Management and Recognition approach to improve the quality of the HIV-related services at its health facilities. This quality improvement intervention relies on comprehensive, detailed assessment tools to communicate and verify adherence to national standards of care, and to test and implement changes to improve performance. A quasi-experimental evaluation of the intervention was conducted at eight Zambia Defence Force primary health facilities (four facilities implemented the intervention and four did not). Data from three previous analyses are combined to assess the effect of Standards-Based Management and Recognition on three domains: facility readiness to provide services; observed provider performance during antiretroviral therapy (ART) and antenatal care consultations; and provider perceptions of the work environment. Facility readiness scores for ART improved on four of the eight standards at intervention sites, and one standard at comparison sites. Facility readiness scores for prevention of mother-to-child transmission (PMTCT) of HIV increased by 15 percentage points at intervention sites and 7 percentage points at comparison sites. Provider performance improved significantly at intervention sites for both ART services (from 58 to 84%; P < 0.01) and PMTCT services (from 58 to 73%; P = 0.003); there was no significant change at comparison sites. Providers' perceptions of the work environment generally improved at intervention sites and declined at comparison sites; differences in trends between study groups were significant for eight items. A standards-based approach to quality improvement proved effective in supporting healthcare managers and providers to deliver ART and PMTCT services in accordance with evidence-based standards in a health system suffering from staff shortages.

  7. Randomized Multilevel Intervention to Improve Outcomes of Residents in Nursing Homes in Need of Improvement

    PubMed Central

    Rantz, Marilyn J.; Nahm, Helen E.; Zwygart-Stauffacher, Mary; Hicks, Lanis; Mehr, David; Flesner, Marcia; Petroski, Gregory F.; Madsen, Richard W.; Scott-Cawiezell, Jill

    2012-01-01

    Purpose A comprehensive multilevel intervention was tested to build organizational capacity to create and sustain improvement in quality of care and subsequently improve resident outcomes in nursing homes in need of improvement. Intervention facilities (n=29) received a two-year multilevel intervention with monthly on-site consultation from expert nurses with graduate education in gerontological nursing. Attention control facilities (n=29) that also needed to improve resident outcomes received monthly information about aging and physical assessment of elders. Design and Methods Randomized clinical trial of nursing homes in need of improving resident outcomes of bladder and bowel incontinence, weight loss, pressure ulcers, and decline in activities of daily living (ADL). It was hypothesized that following the intervention, experimental facilities would have better resident outcomes, higher quality of care, higher staff retention, more organizational attributes of improved working conditions than control facilities, similar staffing and staff mix, and lower total and direct care costs. Results The intervention did improve quality of care (p=0.02); there were improvements in pressure ulcers (p=0.05), weight loss (p=0.05). Staff retention, organizational working conditions, staffing, and staff mix and most costs were not affected by the intervention. Leadership turnover was surprisingly excessive in both intervention and control groups. Implications Some facilities that are in need of improving quality of care and resident outcomes are able to build the organizational capacity to improve while not increasing staffing or costs of care. Improvement requires continuous supportive consultation and leadership willing to involve staff and work together to build the systematic improvements in care delivery needed. PMID:21816681

  8. Short Duration Base Heating Test Improvements

    NASA Technical Reports Server (NTRS)

    Bender, Robert L.; Dagostino, Mark G.; Engel, Bradley A.; Engel, Carl D.

    1999-01-01

    Significant improvements have been made to a short duration space launch vehicle base heating test technique. This technique was first developed during the 1960's to investigate launch vehicle plume induced convective environments. Recent improvements include the use of coiled nitrogen buffer gas lines upstream of the hydrogen / oxygen propellant charge tubes, fast acting solenoid valves, stand alone gas delivery and data acquisition systems, and an integrated model design code. Technique improvements were successfully demonstrated during a 2.25% scale X-33 base heating test conducted in the NASA/MSFC Nozzle Test Facility in early 1999. Cost savings of approximately an order of magnitude over previous tests were realized due in large part to these improvements.

  9. Evaluation of a TB infection control implementation initiative in out-patient HIV clinics in Zambia and Botswana.

    PubMed

    Emerson, C; Lipke, V; Kapata, N; Mwananyambe, N; Mwinga, A; Garekwe, M; Lanje, S; Moshe, Y; Pals, S L; Nakashima, A K; Miller, B

    2016-07-01

    Out-patient human immunodeficiency virus (HIV) care and treatment clinics in Zambia and Botswana, countries with a high burden of HIV and TB infection. To develop a tuberculosis infection control (TB IC) training and implementation package and evaluate the implementation of TB IC activities in facilities implementing the package. Prospective program evaluation of a TB IC training and implementation package using a standardized facility risk assessment tool, qualitative interviews with facility health care workers and measures of pre- and post-test performance. A composite measure of facility performance in TB IC improved from 32% at baseline to 50% at 1 year among eight facilities in Zambia, and from 27% to 80% at 6 months among 10 facilities in Botswana. Although there was marked improvement in indicators of managerial, administrative and environmental controls, key ongoing challenges remained in ensuring access to personal protective equipment and implementing TB screening in health care workers. TB IC activities at out-patient HIV clinics in Zambia and Botswana improved after training using the implementation package. Continued infrastructure support, as well as monitoring and evaluation, are needed to support the scale-up and sustainability of TB IC programs in facilities in low-resource countries.

  10. High-temperature acoustic test facilities and methods

    NASA Astrophysics Data System (ADS)

    Pearson, Jerome

    1994-09-01

    The Wright Laboratory is the Air Force center for air vehicles, responsible for developing advanced technology and incorporating it into new flight vehicles and for continuous technological improvement of operational air vehicles. Part of that responsibility is the problem of acoustic fatigue. With the advent of jet aircraft in the 1950's, acoustic fatigue of aircraft structure became a significant problem. In the 1960's the Wright Laboratory constructed the first large acoustic fatigue test facilities in the United States, and the laboratory has been a dominant factor in high-intensity acoustic testing since that time. This paper discusses some of the intense environments encountered by new and planned Air Force flight vehicles, and describes three new acoustic test facilities of the Wright Laboratory designed for testing structures in these dynamic environments. These new test facilities represent the state of the art in high-temperature, high-intensity acoustic testing and random fatigue testing. They will allow the laboratory scientists and engineers to test the new structures and materials required to withstand the severe environments of captive-carry missiles, augmented lift wings and flaps, exhaust structures of stealth aircraft, and hypersonic vehicle structures well into the twenty-first century.

  11. Proposed Facility Modifications to Support Propulsion Systems Testing Under Simulated Space Conditions at Plum Brook Station's Spacecraft Propulsion Research Facility (B-2)

    NASA Technical Reports Server (NTRS)

    Edwards, Daryl A.

    2008-01-01

    Preparing NASA's Plum Brook Station's Spacecraft Propulsion Research Facility (B-2) to support NASA's new generation of launch vehicles has raised many challenges for B-2's support staff. The facility provides a unique capability to test chemical propulsion systems/vehicles while simulating space thermal and vacuum environments. Designed and constructed in the early 1960s to support upper stage cryogenic engine/vehicle system development, the Plum Brook Station B-2 facility will require modifications to support the larger, more powerful, and more advanced engine systems for the next generation of vehicles leaving earth's orbit. Engine design improvements over the years have included large area expansion ratio nozzles, greater combustion chamber pressures, and advanced materials. Consequently, it has become necessary to determine what facility changes are required and how the facility can be adapted to support varying customers and their specific test needs. Exhaust system performance, including understanding the present facility capabilities, is the primary focus of this work. A variety of approaches and analytical tools are being employed to gain this understanding. This presentation discusses some of the challenges in applying these tools to this project and expected facility configuration to support the varying customer needs.

  12. Proposed Facility Modifications to Support Propulsion Systems Testing Under Simulated Space Conditions at Plum Brook Station's Spacecraft Propulsion Research Facility (B-2)

    NASA Technical Reports Server (NTRS)

    Edwards, Daryl A.

    2007-01-01

    Preparing NASA's Plum Brook Station's Spacecraft Propulsion Research Facility (B-2) to support NASA's new generation of launch vehicles has raised many challenges for B-2 s support staff. The facility provides a unique capability to test chemical propulsion systems/vehicles while simulating space thermal and vacuum environments. Designed and constructed 4 decades ago to support upper stage cryogenic engine/vehicle system development, the Plum Brook Station B-2 facility will require modifications to support the larger, more powerful, and more advanced engine systems for the next generation of vehicles leaving earth's orbit. Engine design improvements over the years have included large area expansion ratio nozzles, greater combustion chamber pressures, and advanced materials. Consequently, it has become necessary to determine what facility changes are required and how the facility can be adapted to support varying customers and their specific test needs. Instrumental in this task is understanding the present facility capabilities and identifying what reasonable changes can be implemented. A variety of approaches and analytical tools are being employed to gain this understanding. This paper discusses some of the challenges in applying these tools to this project and expected facility configuration to support the varying customer needs.

  13. 42 CFR 493.2001 - Establishment and function of the Clinical Laboratory Improvement Advisory Committee.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... laboratory testing or methodology, and others as approved by HHS. (c) HHS will designate specialized...: (1) Criteria for categorizing nonwaived testing; (2) Determination of waived tests; (3) Personnel standards; (4) Facility administration and quality systems standards. (5) Proficiency testing standards; (6...

  14. 42 CFR 493.2001 - Establishment and function of the Clinical Laboratory Improvement Advisory Committee.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... laboratory testing or methodology, and others as approved by HHS. (c) HHS will designate specialized...: (1) Criteria for categorizing nonwaived testing; (2) Determination of waived tests; (3) Personnel standards; (4) Facility administration and quality systems standards. (5) Proficiency testing standards; (6...

  15. 42 CFR 493.2001 - Establishment and function of the Clinical Laboratory Improvement Advisory Committee.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... laboratory testing or methodology, and others as approved by HHS. (c) HHS will designate specialized...: (1) Criteria for categorizing nonwaived testing; (2) Determination of waived tests; (3) Personnel standards; (4) Facility administration and quality systems standards. (5) Proficiency testing standards; (6...

  16. James Webb Space Telescope (JWST) Integrated Science Instruments Module (ISIM) Cryo-Vacuum (CV) Test Campaign Summary

    NASA Technical Reports Server (NTRS)

    Yew, Calinda; Lui, Yan; Whitehouse, Paul; Banks, Kimberly

    2016-01-01

    JWST Integrated Science Instruments Module (ISIM) completed its system-level space simulation testing program at the NASA Goddard Space Flight Center (GSFC). In March 2016, ISIM was successfully delivered to the next level of integration with the Optical Telescope Element (OTE), to form OTIS (OTE + ISIM), after concluding a series of three cryo-vacuum (CV) tests. During these tests, the complexity of the mission has generated challenging requirements that demand highly reliable system performance and capabilities from the Space Environment Simulator (SES) vacuum chamber. The first test served as a risk reduction test; the second test provided the initial verification of the fully-integrated flight instruments; and the third test verified the system in its final flight configuration following mechanical environmental tests (vibration and acoustics). From one test to the next, shortcomings of the facility were uncovered and associated improvements in operational capabilities and reliability of the facility were required to enable the project to verify system-level requirements. This paper: (1) provides an overview of the integrated mechanical and thermal facility systems required to achieve the objectives of JWST ISIM testing, (2) compares the overall facility performance and instrumentation results from the three ISIM CV tests, and (3) summarizes lessons learned from the ISIM testing campaign.

  17. Centaur Rocket in Space Propulsion Research Facility (B-2)

    NASA Image and Video Library

    1969-07-21

    A Centaur second-stage rocket in the Space Propulsion Research Facility, better known as B‒2, operating at NASA’s Plum Brook Station in Sandusky, Ohio. Centaur was designed to be used with an Atlas booster to send the Surveyor spacecraft to the moon in the mid-1960s. After those missions, the rocket was modified to launch a series of astronomical observation satellites into orbit and send space probes to other planets. Researchers conducted a series of systems tests at the Plum Brook test stands to improve the Centaur fuel pumping system. Follow up full-scale tests in the B-2 facility led to the eventual removal of the boost pumps from the design. This reduced the system’s complexity and significantly reduced the cost of a Centaur rocket. The Centaur tests were the first use of the new B-2 facility. B‒2 was the world's only high altitude test facility capable of full-scale rocket engine and launch vehicle system level tests. It was created to test rocket propulsion systems with up to 100,000 pounds of thrust in a simulated space environment. The facility has the unique ability to maintain a vacuum at the rocket’s nozzle while the engine is firing. The rocket fires into a 120-foot deep spray chamber which cools the exhaust before it is ejected outside the facility. B‒2 simulated space using giant diffusion pumps to reduce chamber pressure 10-6 torr, nitrogen-filled cold walls create cryogenic temperatures, and quartz lamps replicate the radiation of the sun.

  18. CONCEPTUAL DESIGN ASSESSMENT FOR THE CO-FIRING OF BIO-REFINERY SUPPLIED LIGNIN PROJECT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ted Berglund; Jeffrey T. Ranney; Carol L. Babb

    2001-01-01

    The major aspects of this project are proceeding toward completion. Prior to this quarter, design criteria, tentative site selection, facility layout, and preliminary facility cost estimates have been completed and issued for review. Processing of bio-solids was completed, providing material for the pilot operations. Pilot facility design, equipment selection, and modification were completed during the fourth quarter. Initial pilot facility shakedown was completed during the fourth quarter. During pilot plant shakedown operations, several production batch test runs were performed. These pilot tests were coupled with laboratory testing to confirm pilot results. In initial batches of operations, cellulose to glucose conversionsmore » of 62.5% and 64.8% were observed in laboratory hydrolysis. As part of this testing, lignin dewatering was tested using laboratory and vendor-supplied filtration equipment. Dewatering tests reported moisture contents in the lignin of between 50% and 60%. Dewatering parameters and options will continue to be investigated during lignin production. After some unavoidable delays, a suitable representative supply of MSW feed material was procured. Shredding of the feed material was completed and final drying of the feed is expected to be completed by late January. Once feed drying is completed, pilot facility production will begin to produce lignin for co-fire testing. Facility modifications are expected to continue to improve facility operations and performance during the first quarter of 2001. The TVA-Colbert facility continues to make progress in evaluating the co-location of the Masada facility on the operation of the power generation facility. The TVA-Colbert fossil plant is fully capable of providing a reliable steam supply. The preferred steam supply connection points and steam pipeline routing have been identified. The environmental review of the pipeline routing has been completed and no major impacts have been identified. Detailed assessment of steam export impacts on the Colbert boiler system continues.« less

  19. Contamination Sources Effects Analysis (CSEA) - A Tool to Balance Cost/Schedule While Managing Facility Availability

    NASA Technical Reports Server (NTRS)

    Wilcox, Margaret

    2008-01-01

    A CSEA is similar to a Failure Modes Effects Analysis (FMEA). A CSEA tracks risk, deterrence, and occurrence of sources of contamination and their mitigation plans. Documentation is provided spanning mechanical and electrical assembly, precision cleaning, thermal vacuum bake-out, and thermal vacuum testing. These facilities all may play a role in contamination budgeting and reduction ultimately affecting test and flight. With a CSEA, visibility can be given to availability of these facilities, test sequencing and trade-offs. A cross-functional team including specialty engineering, contamination control, electrostatic dissipation, manufacturing, testing, and material engineering participate in an exercise that identifies contaminants and minimizes the complexity of scheduling these facilities considering their volatile schedules. Care can be taken in an efficient manner to insure correct cleaning processes are employed. The result is reduction in cycle time ("schedule hits"), reduced cost due to rework, reduced risk and improved communication and quality while achieving adherence to the Contamination Control Plan.

  20. Development and testing of the Shenandoah collector

    NASA Technical Reports Server (NTRS)

    Kinoshita, G. S.

    1981-01-01

    The test and development of the 7-meter Shenandoah parabolic dish collector incorporating an FEK-244 film reflective surface and cavity receiver are described. Four prototypes tested in the midtemperature Solar System Test Facility indicate, with changes incorporated from these development tests, that the improvements should lead to predicted performance levels in the production collectors.

  1. Langley Aircraft Landing Dynamics Facility

    NASA Technical Reports Server (NTRS)

    Davis, Pamela A.; Stubbs, Sandy M.; Tanner, John A.

    1987-01-01

    The Langley Research Center has recently upgraded the Landing Loads Track (LLT) to improve the capability of low-cost testing of conventional and advanced landing gear systems. The unique feature of the Langley Aircraft Landing Dynamics Facility (ALDF) is the ability to test aircraft landing gear systems on actual runway surfaces at operational ground speeds and loading conditions. A historical overview of the original LLT is given, followed by a detailed description of the new ALDF systems and operational capabilities.

  2. Preliminary Report on Oak Ridge National Laboratory Testing of Drake/ACSS/MA2/E3X

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Irminger, Philip; King, Daniel J.; Herron, Andrew N.

    2016-01-01

    A key to industry acceptance of a new technology is extensive validation in field trials. The Powerline Conductor Accelerated Test facility (PCAT) at Oak Ridge National Laboratory (ORNL) is specifically designed to evaluate the performance and reliability of a new conductor technology under real world conditions. The facility is set up to capture large amounts of data during testing. General Cable used the ORNL PCAT facility to validate the performance of TransPowr with E3X Technology a standard overhead conductor with an inorganic high emissivity, low absorptivity surface coating. Extensive testing has demonstrated a significant improvement in conductor performance across amore » wide range of operating temperatures, indicating that E3X Technology can provide a reduction in temperature, a reduction in sag, and an increase in ampacity when applied to the surface of any overhead conductor. This report provides initial results of that testing.« less

  3. 25th Space Simulation Conference. Environmental Testing: The Earth-Space Connection

    NASA Technical Reports Server (NTRS)

    Packard, Edward

    2008-01-01

    Topics covered include: Methods of Helium Injection and Removal for Heat Transfer Augmentation; The ESA Large Space Simulator Mechanical Ground Support Equipment for Spacecraft Testing; Temperature Stability and Control Requirements for Thermal Vacuum/Thermal Balance Testing of the Aquarius Radiometer; The Liquid Nitrogen System for Chamber A: A Change from Original Forced Flow Design to a Natural Flow (Thermo Siphon) System; Return to Mercury: A Comparison of Solar Simulation and Flight Data for the MESSENGER Spacecraft; Floating Pressure Conversion and Equipment Upgrades of Two 3.5kw, 20k, Helium Refrigerators; Affect of Air Leakage into a Thermal-Vacuum Chamber on Helium Refrigeration Heat Load; Special ISO Class 6 Cleanroom for the Lunar Reconnaissance Orbiter (LRO) Project; A State-of-the-Art Contamination Effects Research and Test Facility Martian Dust Simulator; Cleanroom Design Practices and Their Influence on Particle Counts; Extra Terrestrial Environmental Chamber Design; Contamination Sources Effects Analysis (CSEA) - A Tool to Balance Cost/Schedule While Managing Facility Availability; SES and Acoustics at GSFC; HST Super Lightweight Interchangeable Carrier (SLIC) Static Test; Virtual Shaker Testing: Simulation Technology Improves Vibration Test Performance; Estimating Shock Spectra: Extensions beyond GEVS; Structural Dynamic Analysis of a Spacecraft Multi-DOF Shaker Table; Direct Field Acoustic Testing; Manufacture of Cryoshroud Surfaces for Space Simulation Chambers; The New LOTIS Test Facility; Thermal Vacuum Control Systems Options for Test Facilities; Extremely High Vacuum Chamber for Low Outgassing Processing at NASA Goddard; Precision Cleaning - Path to Premier; The New Anechoic Shielded Chambers Designed for Space and Commercial Applications at LIT; Extraction of Thermal Performance Values from Samples in the Lunar Dust Adhesion Bell Jar; Thermal (Silicon Diode) Data Acquisition System; Aquarius's Instrument Science Data System (ISDS) Automated to Acquire, Process, Trend Data and Produce Radiometric System Assessment Reports; Exhaustive Thresholds and Resistance Checkpoints; Reconfigurable HIL Testing of Earth Satellites; FPGA Control System for the Automated Test of MicroShutters; Ongoing Capabilities and Developments of Re-Entry Plasma Ground Tests at EADS-ASTRIUM; Operationally Responsive Space Standard Bus Battery Thermal Balance Testing and Heat Dissipation Analysis; Galileo - The Serial-Production AIT Challenge; The Space Systems Environmental Test Facility Database (SSETFD), Website Development Status; Simulated Reentry Heating by Torching; Micro-Vibration Measurements on Thermally Loaded Multi-Layer Insulation Samples in Vacuum; High Temperature Life Testing of 80Ni-20Cr Wire in a Simulated Mars Atmosphere for the Sample Analysis at Mars (SAM) Instrument Suit Gas Processing System (GPS) Carbon Dioxide Scrubber; The Planning and Implementation of Test Facility Improvements; and Development of a Silicon Carbide Molecular Beam Nozzle for Simulation Planetary Flybys and Low-Earth Orbit.

  4. Results of tests performed on the Acoustic Quiet Flow Facility Three-Dimensional Model Tunnel: Report on the Modified D.S.M.A. Design

    NASA Technical Reports Server (NTRS)

    Barna, P. S.

    1996-01-01

    Numerous tests were performed on the original Acoustic Quiet Flow Facility Three-Dimensional Model Tunnel, scaled down from the full-scale plans. Results of tests performed on the original scale model tunnel were reported in April 1995, which clearly showed that this model was lacking in performance. Subsequently this scale model was modified to attempt to possibly improve the tunnel performance. The modifications included: (a) redesigned diffuser; (b) addition of a collector; (c) addition of a Nozzle-Diffuser; (d) changes in location of vent-air. Tests performed on the modified tunnel showed a marked improvement in performance amounting to a nominal increase of pressure recovery in the diffuser from 34 percent to 54 percent. Results obtained in the tests have wider application. They may also be applied to other tunnels operating with an open test section not necessarily having similar geometry as the model under consideration.

  5. Household trends in access to improved water sources and sanitation facilities in Vietnam and associated factors: findings from the Multiple Indicator Cluster Surveys, 2000–2011

    PubMed Central

    Tuyet-Hanh, Tran Thi; Lee, Jong-Koo; Oh, Juhwan; Van Minh, Hoang; Ou Lee, Chul; Hoan, Le Thi; Nam, You-Seon; Long, Tran Khanh

    2016-01-01

    Background Despite progress made by the Millennium Development Goal (MDG) number 7.C, Vietnam still faces challenges with regard to the provision of access to safe drinking water and basic sanitation. Objective This paper describes household trends in access to improved water sources and sanitation facilities separately, and analyses factors associated with access to improved water sources and sanitation facilities in combination. Design Secondary data from the Vietnam Multiple Indicator Cluster Survey in 2000, 2006, and 2011 were analyzed. Descriptive statistics and tests of significance describe trends over time in access to water and sanitation by location, demographic and socio-economic factors. Binary logistic regressions (2000, 2006, and 2011) describe associations between access to water and sanitation, and geographic, demographic, and socio-economic factors. Results There have been some outstanding developments in access to improved water sources and sanitation facilities from 2000 to 2011. In 2011, the proportion of households with access to improved water sources and sanitation facilities reached 90% and 77%, respectively, meeting the 2015 MDG targets for safe drinking water and basic sanitation set at 88% and 75%, respectively. However, despite these achievements, in 2011, only 74% of households overall had access to combined improved drinking water and sanitation facilities. There were also stark differences between regions. In 2011, only 47% of households had access to both improved water and sanitation facilities in the Mekong River Delta compared with 94% in the Red River Delta. In 2011, households in urban compared to rural areas were more than twice as likely (odds ratio [OR]: 2.2; 95% confidence interval [CI]: 1.9–2.5) to have access to improved water and sanitation facilities in combination, and households in the highest compared with the lowest wealth quintile were over 40 times more likely (OR: 42.3; 95% CI: 29.8–60.0). Conclusions More efforts are required to increase household access to both improved water and sanitation facilities in the Mekong River Delta, South East and Central Highlands regions of Vietnam. There is also a need to address socio-economic factors associated with inadequate access to improved sanitation facilities. PMID:26950563

  6. The ASCENT (Allocation System Changes for Equity in Kidney Transplantation) Study: a Randomized Effectiveness-Implementation Study to Improve Kidney Transplant Waitlisting and Reduce Racial Disparity.

    PubMed

    Patzer, Rachel E; Smith, Kayla; Basu, Mohua; Gander, Jennifer; Mohan, Sumit; Escoffery, Cam; Plantinga, Laura; Melanson, Taylor; Kalloo, Sean; Green, Gary; Berlin, Alex; Renville, Gary; Browne, Teri; Turgeon, Nicole; Caponi, Susan; Zhang, Rebecca; Pastan, Stephen

    2017-05-01

    The United Network for Organ Sharing (UNOS) implemented a new Kidney Allocation System (KAS) in December 2014 that is expected to substantially reduce racial disparities in kidney transplantation among waitlisted patients. However, not all dialysis facility clinical providers and end stage renal disease (ESRD) patients are aware of how the policy change could improve access to transplant. We describe the ASCENT (Allocation System Changes for Equity in KidNey Transplantation) study, a randomized controlled effectiveness-implementation study designed to test the effectiveness of a multicomponent intervention to improve access to the early steps of kidney transplantation among dialysis facilities across the United States. The multicomponent intervention consists of an educational webinar for dialysis medical directors, an educational video for patients and an educational video for dialysis staff, and a dialysis-facility specific transplant performance feedback report. Materials will be developed by a multidisciplinary dissemination advisory board and will undergo formative testing in dialysis facilities across the United States. This study is estimated to enroll ~600 U.S. dialysis facilities with low waitlisting in all 18 ESRD Networks. The co-primary outcomes include change in waitlisting, and waitlist disparity at 1 year; secondary outcomes include changes in facility medical director knowledge about KAS, staff training regarding KAS, patient education regarding transplant, and a medical director's intent to refer patients for transplant evaluation. The results from the ASCENT study will demonstrate the feasibility and effectiveness of a multicomponent intervention designed to increase access to the deceased-donor kidney waitlist and reduce racial disparities in waitlisting.

  7. Benchmarking of Improved DPAC Transient Deflagration Analysis Code

    DOE PAGES

    Laurinat, James E.; Hensel, Steve J.

    2017-09-27

    The deflagration pressure analysis code (DPAC) has been upgraded for use in modeling hydrogen deflagration transients. The upgraded code is benchmarked using data from vented hydrogen deflagration tests conducted at the HYDRO-SC Test Facility at the University of Pisa. DPAC originally was written to calculate peak pressures for deflagrations in radioactive waste storage tanks and process facilities at the Savannah River Site. Upgrades include the addition of a laminar flame speed correlation for hydrogen deflagrations and a mechanistic model for turbulent flame propagation, incorporation of inertial effects during venting, and inclusion of the effect of water vapor condensation on vesselmore » walls. In addition, DPAC has been coupled with chemical equilibrium with applications (CEA), a NASA combustion chemistry code. The deflagration tests are modeled as end-to-end deflagrations. As a result, the improved DPAC code successfully predicts both the peak pressures during the deflagration tests and the times at which the pressure peaks.« less

  8. Benchmarking of Improved DPAC Transient Deflagration Analysis Code

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laurinat, James E.; Hensel, Steve J.

    The deflagration pressure analysis code (DPAC) has been upgraded for use in modeling hydrogen deflagration transients. The upgraded code is benchmarked using data from vented hydrogen deflagration tests conducted at the HYDRO-SC Test Facility at the University of Pisa. DPAC originally was written to calculate peak pressures for deflagrations in radioactive waste storage tanks and process facilities at the Savannah River Site. Upgrades include the addition of a laminar flame speed correlation for hydrogen deflagrations and a mechanistic model for turbulent flame propagation, incorporation of inertial effects during venting, and inclusion of the effect of water vapor condensation on vesselmore » walls. In addition, DPAC has been coupled with chemical equilibrium with applications (CEA), a NASA combustion chemistry code. The deflagration tests are modeled as end-to-end deflagrations. As a result, the improved DPAC code successfully predicts both the peak pressures during the deflagration tests and the times at which the pressure peaks.« less

  9. Environmental Control and Life Support Systems Test Facility at MSFC

    NASA Technical Reports Server (NTRS)

    2001-01-01

    The Marshall Space Flight Center (MSFC) is responsible for designing and building the life support systems that will provide the crew of the International Space Station (ISS) a comfortable environment in which to live and work. Scientists and engineers at the MSFC are working together to provide the ISS with systems that are safe, efficient, and cost-effective. These compact and powerful systems are collectively called the Environmental Control and Life Support Systems, or simply, ECLSS. In this photograph, the life test area on the left of the MSFC ECLSS test facility is where various subsystems and components are tested to determine how long they can operate without failing and to identify components needing improvement. Equipment tested here includes the Carbon Dioxide Removal Assembly (CDRA), the Urine Processing Assembly (UPA), the mass spectrometer filament assemblies and sample pumps for the Major Constituent Analyzer (MCA). The Internal Thermal Control System (ITCS) simulator facility (in the module in the right) duplicates the function and operation of the ITCS in the ISS U.S. Laboratory Module, Destiny. This facility provides support for Destiny, including troubleshooting problems related to the ITCS.

  10. Experimental Supersonic Combustion Research at NASA Langley

    NASA Technical Reports Server (NTRS)

    Rogers, R. Clayton; Capriotti, Diego P.; Guy, R. Wayne

    1998-01-01

    Experimental supersonic combustion research related to hypersonic airbreathing propulsion has been actively underway at NASA Langley Research Center (LaRC) since the mid-1960's. This research involved experimental investigations of fuel injection, mixing, and combustion in supersonic flows and numerous tests of scramjet engine flowpaths in LaRC test facilities simulating flight from Mach 4 to 8. Out of this research effort has come scramjet combustor design methodologies, ground test techniques, and data analysis procedures. These technologies have progressed steadily in support of the National Aero-Space Plane (NASP) program and the current Hyper-X flight demonstration program. During NASP nearly 2500 tests of 15 scramjet engine models were conducted in LaRC facilities. In addition, research supporting the engine flowpath design investigated ways to enhance mixing, improve and apply nonintrusive diagnostics, and address facility operation. Tests of scramjet combustor operation at conditions simulating hypersonic flight at Mach numbers up to 17 also have been performed in an expansion tube pulse facility. This paper presents a review of the LaRC experimental supersonic combustion research efforts since the late 1980's, during the NASP program, and into the Hyper-X Program.

  11. Wind Energy Facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laurie, Carol

    2017-02-01

    This book takes readers inside the places where daily discoveries shape the next generation of wind power systems. Energy Department laboratory facilities span the United States and offer wind research capabilities to meet industry needs. The facilities described in this book make it possible for industry players to increase reliability, improve efficiency, and reduce the cost of wind energy -- one discovery at a time. Whether you require blade testing or resource characterization, grid integration or high-performance computing, Department of Energy laboratory facilities offer a variety of capabilities to meet your wind research needs.

  12. Wind Energy Facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Office of Energy Efficiency and Renewable Energy

    This book takes readers inside the places where daily discoveries shape the next generation of wind power systems. Energy Department laboratory facilities span the United States and offer wind research capabilities to meet industry needs. The facilities described in this book make it possible for industry players to increase reliability, improve efficiency, and reduce the cost of wind energy -- one discovery at a time. Whether you require blade testing or resource characterization, grid integration or high-performance computing, Department of Energy laboratory facilities offer a variety of capabilities to meet your wind research needs.

  13. The Hydrologic Instrumentation Facility of the U.S. Geological Survey

    USGS Publications Warehouse

    Wagner, C.R.; Jeffers, Sharon

    1984-01-01

    The U.S. Geological Survey Water Resources Division has improved support to the agencies field offices by the consolidation of all instrumentation support services in a single facility. This facility known as the Hydrologic Instrumentation Facility (HIF) is located at the National Space Technology Laboratory, Mississippi, about 50 miles east of New Orleans, Louisiana. The HIF is responsible for design and development, testing, evaluation, procurement, warehousing, distribution and repair of a variety of specialized hydrologic instrumentation. The centralization has resulted in more efficient and effective support of the Survey 's hydrologic programs. (USGS)

  14. A Method for Calculating the Probability of Successfully Completing a Rocket Propulsion Ground Test

    NASA Technical Reports Server (NTRS)

    Messer, Bradley P.

    2004-01-01

    Propulsion ground test facilities face the daily challenges of scheduling multiple customers into limited facility space and successfully completing their propulsion test projects. Due to budgetary and schedule constraints, NASA and industry customers are pushing to test more components, for less money, in a shorter period of time. As these new rocket engine component test programs are undertaken, the lack of technology maturity in the test articles, combined with pushing the test facilities capabilities to their limits, tends to lead to an increase in facility breakdowns and unsuccessful tests. Over the last five years Stennis Space Center's propulsion test facilities have performed hundreds of tests, collected thousands of seconds of test data, and broken numerous test facility and test article parts. While various initiatives have been implemented to provide better propulsion test techniques and improve the quality, reliability, and maintainability of goods and parts used in the propulsion test facilities, unexpected failures during testing still occur quite regularly due to the harsh environment in which the propulsion test facilities operate. Previous attempts at modeling the lifecycle of a propulsion component test project have met with little success. Each of the attempts suffered form incomplete or inconsistent data on which to base the models. By focusing on the actual test phase of the tests project rather than the formulation, design or construction phases of the test project, the quality and quantity of available data increases dramatically. A logistic regression model has been developed form the data collected over the last five years, allowing the probability of successfully completing a rocket propulsion component test to be calculated. A logistic regression model is a mathematical modeling approach that can be used to describe the relationship of several independent predictor variables X(sub 1), X(sub 2),..,X(sub k) to a binary or dichotomous dependent variable Y, where Y can only be one of two possible outcomes, in this case Success or Failure. Logistic regression has primarily been used in the fields of epidemiology and biomedical research, but lends itself to many other applications. As indicated the use of logistic regression is not new, however, modeling propulsion ground test facilities using logistic regression is both a new and unique application of the statistical technique. Results from the models provide project managers with insight and confidence into the affectivity of rocket engine component ground test projects. The initial success in modeling rocket propulsion ground test projects clears the way for more complex models to be developed in this area.

  15. Experimental aeroelasticity in wind tunnels - History, status, and future in brief

    NASA Technical Reports Server (NTRS)

    Ricketts, Rodney H.

    1993-01-01

    The state of the art of experimental aeroelasticity in the United States is assessed. A brief history of the development of ground test facilities, apparatus, and testing methods is presented. Several experimental programs are described that were previously conducted and helped to improve the state of the art. Some specific future directions for improving and enhancing experimental aeroelasticity are suggested.

  16. Improving district facility readiness: a 12-month evaluation of a data-driven health systems strengthening intervention in rural Rwanda.

    PubMed

    Iyer, Hari S; Kamanzi, Emmanuel; Mugunga, Jean Claude; Finnegan, Karen; Uwingabiye, Alice; Shyaka, Edward; Niyonzima, Saleh; Hirschhorn, Lisa R; Drobac, Peter C

    2015-01-01

    While health systems strengthening (HSS) interventions are recommended by global health policy experts to improve population health in resource-limited settings, few examples exist of evaluations of HSS interventions conducted at the district level. In 2009, a partnership between Partners In Health (PIH), a non-governmental organization, and the Rwandan Ministry of Health (RMOH) was provided funds to implement and evaluate a district-level HSS intervention in two rural districts of Rwanda. The partnership provided limited funds to 14 health centers for targeted systems support in 2010; six others received support prior to the intervention (reference). RMOH health systems norms were mapped across the WHO HSS framework, scored from 0 to 10 and incorporated into a rapid survey assessing 11 domains of facility readiness. Stakeholder meetings allowed partnership leaders to review results, set priorities, and allocate resources. Investments included salary support, infrastructure improvements, medical equipment, and social support for patients. We compared facility domain scores from the start of the intervention to 12 months and tested for correlation between change in score and change in funding allocation to assess equity in our approach. We found significant improvements among intervention facilities from baseline to 12 months across several domains [infrastructure (+4, p=0.0001), clinical services (+1.2, p=0.03), infection and sanitation control (+0.6, p=0.03), medical equipment (+1.0, p=0.02), information use (+2, p=0.002)]. Composite score across domains improved from 6.2 at baseline to 7.4 at 12 months (p=0.002). Across facilities, 50% had composite scores greater than the average score among reference facilities (7.4) at 12 months compared to none at baseline. Rapid facility surveys, stakeholder engagement, and information feedback can be used for gap analysis and resource allocation. This approach can achieve effective use of limited resources, improve facility readiness, and ensure consistency of facility capacity to provide quality care at the district level.

  17. Improving district facility readiness: a 12-month evaluation of a data-driven health systems strengthening intervention in rural Rwanda

    PubMed Central

    Iyer, Hari S.; Kamanzi, Emmanuel; Mugunga, Jean Claude; Finnegan, Karen; Uwingabiye, Alice; Shyaka, Edward; Niyonzima, Saleh; Hirschhorn, Lisa R.; Drobac, Peter C.

    2015-01-01

    Background While health systems strengthening (HSS) interventions are recommended by global health policy experts to improve population health in resource-limited settings, few examples exist of evaluations of HSS interventions conducted at the district level. In 2009, a partnership between Partners In Health (PIH), a non-governmental organization, and the Rwandan Ministry of Health (RMOH) was provided funds to implement and evaluate a district-level HSS intervention in two rural districts of Rwanda. Design The partnership provided limited funds to 14 health centers for targeted systems support in 2010; six others received support prior to the intervention (reference). RMOH health systems norms were mapped across the WHO HSS framework, scored from 0 to 10 and incorporated into a rapid survey assessing 11 domains of facility readiness. Stakeholder meetings allowed partnership leaders to review results, set priorities, and allocate resources. Investments included salary support, infrastructure improvements, medical equipment, and social support for patients. We compared facility domain scores from the start of the intervention to 12 months and tested for correlation between change in score and change in funding allocation to assess equity in our approach. Results We found significant improvements among intervention facilities from baseline to 12 months across several domains [infrastructure (+4, p=0.0001), clinical services (+1.2, p=0.03), infection and sanitation control (+0.6, p=0.03), medical equipment (+1.0, p=0.02), information use (+2, p=0.002)]. Composite score across domains improved from 6.2 at baseline to 7.4 at 12 months (p=0.002). Across facilities, 50% had composite scores greater than the average score among reference facilities (7.4) at 12 months compared to none at baseline. Conclusions Rapid facility surveys, stakeholder engagement, and information feedback can be used for gap analysis and resource allocation. This approach can achieve effective use of limited resources, improve facility readiness, and ensure consistency of facility capacity to provide quality care at the district level. PMID:26140729

  18. Enhancements to the FAST-MAC Circulation Control Model and Recent High-Reynolds Number Testing in the National Transonic Facility

    NASA Technical Reports Server (NTRS)

    Milholen, William E., II; Jones, Gregory S.; Chan, David T.; Goodliff, Scott L.; Anders, Scott G.; Melton, Latunia P.; Carter, Melissa B.; Allan, Brian G.; Capone, Francis J.

    2013-01-01

    A second wind tunnel test of the FAST-MAC circulation control model was recently completed in the National Transonic Facility at the NASA Langley Research Center. The model was equipped with four onboard flow control valves allowing independent control of the circulation control plenums, which were directed over a 15% chord simple-hinged flap. The model was configured for low-speed high-lift testing with flap deflections of 30 and 60 degrees, along with the transonic cruise configuration with zero degree flap deflection. Testing was again conducted over a wide range of Mach numbers up to 0.88, and Reynolds numbers up to 30 million based on the mean chord. The first wind tunnel test had poor transonic force and moment data repeatability at mild cryogenic conditions due to inadequate thermal conditioning of the balance. The second test demonstrated that an improvement to the balance heating system significantly improved the transonic data repeatability, but also indicated further improvements are still needed. The low-speed highlift performance of the model was improved by testing various blowing slot heights, and the circulation control was again demonstrated to be effective in re-attaching the flow over the wing at off-design transonic conditions. A new tailored spanwise blowing technique was also demonstrated to be effective at transonic conditions with the benefit of reduced mass flow requirements.

  19. Proposed aeroelastic and flutter tests for the National Transonic Facility

    NASA Technical Reports Server (NTRS)

    Stevenson, J. R.

    1981-01-01

    Tests that can exploit the capability of the NTF and the transonic cryogenic tunnel, or lead to improvements that could enhance testing in the NTF are discussed. Shock induced oscillation, supersonic single degree control surface flutter, and transonic flutter speed as a function of the Reynolds number are considered. Honeycombs versus screens to smooth the tunnel flow and a rapid tunnel dynamic pressure reducer are recommended to improve tunnel performance.

  20. Wii-Fit for Improving Gait and Balance in an Assisted Living Facility: A Pilot Study

    PubMed Central

    Padala, Kalpana P.; Padala, Prasad R.; Malloy, Timothy R.; Geske, Jenenne A.; Dubbert, Patricia M.; Dennis, Richard A.; Garner, Kimberly K.; Bopp, Melinda M.; Burke, William J.; Sullivan, Dennis H.

    2012-01-01

    Objectives. To determine the effects on balance and gait of a Wii-Fit program compared to a walking program in subjects with mild Alzheimer's dementia (AD). Methods. A prospective randomized (1 : 1) pilot study with two intervention arms was conducted in an assisted living facility with twenty-two mild AD subjects. In both groups the intervention occurred under supervision for 30 minutes daily, five times a week for eight weeks. Repeated measures ANOVA and paired t-tests were used to analyze changes. Results. Both groups showed improvement in Berg Balance Scale (BBS), Tinetti Test (TT) and Timed Up and Go (TUG) over 8 weeks. However, there was no statistically significant difference between the groups over time. Intragroup analysis in the Wii-Fit group showed significant improvement on BBS (P = 0.003), and TT (P = 0.013). The walking group showed a trend towards improvement on BBS (P = 0.06) and TUG (P = 0.07) and significant improvement in TT (P = 0.06). Conclusion. This pilot study demonstrates the safety and efficacy of Wii-Fit in an assisted living facility in subjects with mild AD. Use of Wii-Fit resulted in significant improvements in balance and gait comparable to those in the robust monitored walking program. These results need to be confirmed in a larger, methodologically sound study. PMID:22745909

  1. Improvements in safety testing of lithium cells

    NASA Astrophysics Data System (ADS)

    Stinebring, R. C.; Krehl, P.

    1985-07-01

    A systematic approach was developed for evaluating the basic safety parameters of high power lithium soluble cathode cells. This approach consists of performing a series of tests on each cell model during the design, prototype and production phases. Abusive testing is performed in a facility where maximum protection is given to test personnel.

  2. Improvements in safety testing of lithium cells

    NASA Technical Reports Server (NTRS)

    Stinebring, R. C.; Krehl, P.

    1985-01-01

    A systematic approach was developed for evaluating the basic safety parameters of high power lithium soluble cathode cells. This approach consists of performing a series of tests on each cell model during the design, prototype and production phases. Abusive testing is performed in a facility where maximum protection is given to test personnel.

  3. The prevention of mother-to-child transmission of HIV cascade analysis tool: supporting health managers to improve facility-level service delivery.

    PubMed

    Gimbel, Sarah; Voss, Joachim; Mercer, Mary Anne; Zierler, Brenda; Gloyd, Stephen; Coutinho, Maria de Joana; Floriano, Florencia; Cuembelo, Maria de Fatima; Einberg, Jennifer; Sherr, Kenneth

    2014-10-21

    The objective of the prevention of Mother-to-Child Transmission (pMTCT) cascade analysis tool is to provide frontline health managers at the facility level with the means to rapidly, independently and quantitatively track patient flows through the pMTCT cascade, and readily identify priority areas for clinic-level improvement interventions. Over a period of six months, five experienced maternal-child health managers and researchers iteratively adapted and tested this systems analysis tool for pMTCT services. They prioritized components of the pMTCT cascade for inclusion, disseminated multiple versions to 27 health managers and piloted it in five facilities. Process mapping techniques were used to chart PMTCT cascade steps in these five facilities, to document antenatal care attendance, HIV testing and counseling, provision of prophylactic anti-retrovirals, safe delivery, safe infant feeding, infant follow-up including HIV testing, and family planning, in order to obtain site-specific knowledge of service delivery. Seven pMTCT cascade steps were included in the Excel-based final tool. Prevalence calculations were incorporated as sub-headings under relevant steps. Cells not requiring data inputs were locked, wording was simplified and stepwise drop-offs and maximization functions were included at key steps along the cascade. While the drop off function allows health workers to rapidly assess how many patients were lost at each step, the maximization function details the additional people served if only one step improves to 100% capacity while others stay constant. Our experience suggests that adaptation of a cascade analysis tool for facility-level pMTCT services is feasible and appropriate as a starting point for discussions of where to implement improvement strategies. The resulting tool facilitates the engagement of frontline health workers and managers who fill out, interpret, apply the tool, and then follow up with quality improvement activities. Research on adoption, interpretation, and sustainability of this pMTCT cascade analysis tool by frontline health managers is needed. ClinicalTrials.gov NCT02023658, December 9, 2013.

  4. Development and Demonstration of a Computational Tool for the Analysis of Particle Vitiation Effects in Hypersonic Propulsion Test Facilities

    NASA Technical Reports Server (NTRS)

    Perkins, Hugh Douglas

    2010-01-01

    In order to improve the understanding of particle vitiation effects in hypersonic propulsion test facilities, a quasi-one dimensional numerical tool was developed to efficiently model reacting particle-gas flows over a wide range of conditions. Features of this code include gas-phase finite-rate kinetics, a global porous-particle combustion model, mass, momentum and energy interactions between phases, and subsonic and supersonic particle drag and heat transfer models. The basic capabilities of this tool were validated against available data or other validated codes. To demonstrate the capabilities of the code a series of computations were performed for a model hypersonic propulsion test facility and scramjet. Parameters studied were simulated flight Mach number, particle size, particle mass fraction and particle material.

  5. Status of the use and compliance with malaria rapid diagnostic tests in formal private health facilities in Nigeria.

    PubMed

    Mokuolu, Olugbenga A; Ntadom, Godwin N; Ajumobi, Olufemi O; Alero, Roberts A; Wammanda, Robinson D; Adedoyin, Olanrewaju T; Okafor, Henrietta U; Alabi, Adekunle D; Odey, Friday A; Agomo, Chimere O; Edozieh, Kate U; Fagbemi, Tolulope O; Njidda, Ahmad M; Babatunde, Seye; Agbo, Emmanuel C; Nwaneri, Nnamdi B; Shekarau, Emmanuel D; Obasa, Temitope O; Ezeigwe, Nnenna M

    2016-01-04

    Nigeria has the largest number of malaria-related deaths, accounting for a third of global malaria deaths. It is important that the country attains universal coverage of key malaria interventions, one of which is the policy of universal testing before treatment, which the country has recently adopted. However, there is a dearth of data on its implementation in formal private health facilities, where close to a third of the population seek health care. This study identified the level of use of malaria rapid diagnostic testing (RDT), compliance with test results and associated challenges in the formal private health facilities in Nigeria. A cross-sectional study that involved a multi-stage, random sampling of 240 formal private health facilities from the country's six geo-political zones was conducted from July to August 2014. Data were collected using health facility records, healthcare workers' interviews and an exit survey of febrile patients seen at the facilities, in order to determine fever prevalence, level of testing of febrile patience, compliance with test results, and health workers' perceptions to RDT use. Data from the 201 health facilities analysed indicated a fever prevalence of 38.5% (112,521/292,430). Of the 2077 exit interviews for febrile patients, malaria testing was ordered in 73.8% (95% CI 71.7-75.7%). Among the 1270 tested, 61.8% (719/1270) were tested with microscopy and 38.2% (445/1270) with RDT. Compliance to malaria test result [administering arteminisin-based combination therapy (ACT) to positive patients and withholding ACT from negative patients] was 80.9% (95% CI 78.7-83%). Compliance was not influenced by the age of patients or type of malaria test. The health facilities have various cadres of the health workers knowledgeable on RDT with 70% knowing the meaning, while 84.5% knew what it assesses. However, there was clearly a preference for microscopy as only 20% reported performing only RDT. In formal private health facilities in Nigeria there is a high rate of malaria testing for febrile patients, high level of compliance with test results but relatively low level of RDT utilization. This calls for improved engagement of the formal private health sector with a view to achieving universal coverage targets on malaria testing.

  6. A Summary of DOD-Sponsored Research Performed at NASA Langley's Impact Dynamics Research Facility

    NASA Technical Reports Server (NTRS)

    Jackson, Karen E.; Boitnott, Richard L.; Fasanella, Edwin L.; Jones, Lisa E.; Lyle, Karen H.

    2004-01-01

    The Impact Dynamics Research Facility (IDRF) is a 240-ft.-high gantry structure located at NASA Langley Research Center in Hampton, Virginia. The IDRF was originally built in the early 1960's for use as a Lunar Landing Research Facility. As such, the facility was configured to simulate the reduced gravitational environment of the Moon, allowing the Apollo astronauts to practice lunar landings under realistic conditions. In 1985, the IDRF was designated a National Historic Landmark based on its significant contributions to the Apollo Moon Landing Program. In the early 1970's the facility was converted into its current configuration as a full-scale crash test facility for light aircraft and rotorcraft. Since that time, the IDRF has been used to perform a wide variety of impact tests on full-scale aircraft, airframe components, and space vehicles in support of the General Aviation (GA) aircraft industry, the U.S. Department of Defense (DOD), the rotorcraft industry, and the NASA Space program. The objectives of this paper are twofold: to describe the IDRF facility and its unique capabilities for conducting structural impact testing, and to summarize the impact tests performed at the IDRF in support of the DOD. These tests cover a time period of roughly 2 1/2 decades, beginning in 1975 with the full-scale crash test of a CH-47 Chinook helicopter, and ending in 1999 with the external fuel system qualification test of a UH-60 Black Hawk helicopter. NASA officially closed the IDRF in September 2003; consequently, it is important to document the past contributions made in improved human survivability and impact tolerance through DOD-sponsored research performed at the IDRF.

  7. Safety Analysis and Protection Measures of the Control System of the Pulsed High Magnetic Field Facility in WHMFC

    NASA Astrophysics Data System (ADS)

    Shi, J. T.; Han, X. T.; Xie, J. F.; Yao, L.; Huang, L. T.; Li, L.

    2013-03-01

    A Pulsed High Magnetic Field Facility (PHMFF) has been established in Wuhan National High Magnetic Field Center (WHMFC) and various protection measures are applied in its control system. In order to improve the reliability and robustness of the control system, the safety analysis of the PHMFF is carried out based on Fault Tree Analysis (FTA) technique. The function and realization of 5 protection systems, which include sequence experiment operation system, safety assistant system, emergency stop system, fault detecting and processing system and accident isolating protection system, are given. The tests and operation indicate that these measures improve the safety of the facility and ensure the safety of people.

  8. Design and utilization of a Flight Test Engineering Database Management System at the NASA Dryden Flight Research Facility

    NASA Technical Reports Server (NTRS)

    Knighton, Donna L.

    1992-01-01

    A Flight Test Engineering Database Management System (FTE DBMS) was designed and implemented at the NASA Dryden Flight Research Facility. The X-29 Forward Swept Wing Advanced Technology Demonstrator flight research program was chosen for the initial system development and implementation. The FTE DBMS greatly assisted in planning and 'mass production' card preparation for an accelerated X-29 research program. Improved Test Plan tracking and maneuver management for a high flight-rate program were proven, and flight rates of up to three flights per day, two times per week were maintained.

  9. Test Results From a Simulated High-Voltage Lunar Power Transmission Line

    NASA Technical Reports Server (NTRS)

    Birchenough, Arthur; Hervol, David

    2008-01-01

    The Alternator Test Unit (ATU) in the Lunar Power System Facility (LPSF) located at the NASA Glenn Research Center (GRC) in Cleveland, Ohio was modified to simulate high-voltage transmission capability. The testbed simulated a 1 km transmission cable length from the ATU to the LPSF using resistors and inductors installed between the distribution transformers. Power factor correction circuitry was used to compensate for the reactance of the distribution system to improve the overall power factor. This test demonstrated that a permanent magnet alternator can successfully provide high-frequency ac power to a lunar facility located at a distance.

  10. Test Results from a Simulated High Voltage Lunar Power Transmission Line

    NASA Technical Reports Server (NTRS)

    Birchenough, Arthur; Hervol, David

    2008-01-01

    The Alternator Test Unit (ATU) in the Lunar Power System Facility (LPSF) located at the NASA Glenn Research Center (GRC) in Cleveland, OH was modified to simulate high voltage transmission capability. The testbed simulated a 1 km transmission cable length from the ATU to the LPSF using resistors and inductors installed between the distribution transformers. Power factor correction circuitry was used to compensate for the reactance of the distribution system to improve the overall power factor. This test demonstrated that a permanent magnet alternator can successfully provide high frequency AC power to a lunar facility located at a distance.

  11. Achieving walkable city in Indonesia: Policy and responsive design through public participation

    NASA Astrophysics Data System (ADS)

    Tanan, Natalia; Darmoyono, Laksmi

    2017-11-01

    This paper discusses approaches to policy and planning of pedestrian facility that facilitate walking in cities in Indonesia. It applies quantitative and qualitative methods to analyze walkability in some cities. The new perspective in policy and planning are focusing on improving non-motorized mobility; it encourages walking and put the provision of the pedestrian facility as an integral part of built environmental planning and development. The policy perceives pedestrian facility in broad, not only about physical development, but also benefit to socioeconomic activity and environmental quality. It is expected that the implementation of policies and walkability concept could upgrade the pedestrian facility, as a walkable city delivers green atmosphere of the urban environment. A design competition of pedestrian facility was held to test the policy and accommodate input from the public. Public participation through competition also enriches the design of pedestrian facility that responsive to local condition. Implementation is still a challenge due to limited budget; however, there are tendencies that few cities improve pedestrian facilities to encourage people walking in order to make the city livable and environmentally friendly.

  12. Measuring Quality Gaps in TB Screening in South Africa Using Standardised Patient Analysis.

    PubMed

    Christian, Carmen S; Gerdtham, Ulf-G; Hompashe, Dumisani; Smith, Anja; Burger, Ronelle

    2018-04-12

    This is the first multi-district Standardised Patient (SP) study in South Africa. It measures the quality of TB screening at primary healthcare (PHC) facilities. We hypothesise that TB screening protocols and best practices are poorly adhered to at the PHC level. The SP method allows researchers to observe how healthcare providers identify, test and advise presumptive TB patients, and whether this aligns with clinical protocols and best practice. The study was conducted at PHC facilities in two provinces and 143 interactions at 39 facilities were analysed. Only 43% of interactions resulted in SPs receiving a TB sputum test and being offered an HIV test. TB sputum tests were conducted routinely (84%) while HIV tests were offered less frequently (47%). Nurses frequently neglected to ask SPs whether their household contacts had confirmed TB (54%). Antibiotics were prescribed without taking temperatures in 8% of cases. The importance of returning to the facility to receive TB test results was only explained in 28%. The SP method has highlighted gaps in clinical practice, signalling missed opportunities. Early detection of sub-optimal TB care is instrumental in decreasing TB-related morbidity and mortality. The findings provide the rationale for further quality improvement work in TB management.

  13. Systems analysis and improvement to optimize pMTCT (SAIA): a cluster randomized trial

    PubMed Central

    2014-01-01

    Background Despite significant increases in global health investment and the availability of low-cost, efficacious interventions to prevent mother-to-child HIV transmission (pMTCT) in low- and middle-income countries with high HIV burden, the translation of scientific advances into effective delivery strategies has been slow, uneven and incomplete. As a result, pediatric HIV infection remains largely uncontrolled. A five-step, facility-level systems analysis and improvement intervention (SAIA) was designed to maximize effectiveness of pMTCT service provision by improving understanding of inefficiencies (step one: cascade analysis), guiding identification and prioritization of low-cost workflow modifications (step two: value stream mapping), and iteratively testing and redesigning these modifications (steps three through five). This protocol describes the SAIA intervention and methods to evaluate the intervention’s impact on reducing drop-offs along the pMTCT cascade. Methods This study employs a two-arm, longitudinal cluster randomized trial design. The unit of randomization is the health facility. A total of 90 facilities were identified in Côte d’Ivoire, Kenya and Mozambique (30 per country). A subset was randomly selected and assigned to intervention and comparison arms, stratified by country and service volume, resulting in 18 intervention and 18 comparison facilities across all three countries, with six intervention and six comparison facilities per country. The SAIA intervention will be implemented for six months in the 18 intervention facilities. Primary trial outcomes are designed to assess improvements in the pMTCT service cascade, and include the percentage of pregnant women being tested for HIV at the first antenatal care visit, the percentage of HIV-infected pregnant women receiving adequate prophylaxis or combination antiretroviral therapy in pregnancy, and the percentage of newborns exposed to HIV in pregnancy receiving an HIV diagnosis eight weeks postpartum. The Consolidated Framework for Implementation Research (CFIR) will guide collection and analysis of qualitative data on implementation process. Discussion This study is a pragmatic trial that has the potential benefit of improving maternal and infant outcomes by reducing drop-offs along the pMTCT cascade. The SAIA intervention is designed to provide simple tools to guide decision-making for pMTCT program staff at the facility level, and to identify low cost, contextually appropriate pMTCT improvement strategies. Trial registration ClinicalTrials.gov NCT02023658 PMID:24885976

  14. Systems analysis and improvement to optimize pMTCT (SAIA): a cluster randomized trial.

    PubMed

    Sherr, Kenneth; Gimbel, Sarah; Rustagi, Alison; Nduati, Ruth; Cuembelo, Fatima; Farquhar, Carey; Wasserheit, Judith; Gloyd, Stephen

    2014-05-08

    Despite significant increases in global health investment and the availability of low-cost, efficacious interventions to prevent mother-to-child HIV transmission (pMTCT) in low- and middle-income countries with high HIV burden, the translation of scientific advances into effective delivery strategies has been slow, uneven and incomplete. As a result, pediatric HIV infection remains largely uncontrolled. A five-step, facility-level systems analysis and improvement intervention (SAIA) was designed to maximize effectiveness of pMTCT service provision by improving understanding of inefficiencies (step one: cascade analysis), guiding identification and prioritization of low-cost workflow modifications (step two: value stream mapping), and iteratively testing and redesigning these modifications (steps three through five). This protocol describes the SAIA intervention and methods to evaluate the intervention's impact on reducing drop-offs along the pMTCT cascade. This study employs a two-arm, longitudinal cluster randomized trial design. The unit of randomization is the health facility. A total of 90 facilities were identified in Côte d'Ivoire, Kenya and Mozambique (30 per country). A subset was randomly selected and assigned to intervention and comparison arms, stratified by country and service volume, resulting in 18 intervention and 18 comparison facilities across all three countries, with six intervention and six comparison facilities per country. The SAIA intervention will be implemented for six months in the 18 intervention facilities. Primary trial outcomes are designed to assess improvements in the pMTCT service cascade, and include the percentage of pregnant women being tested for HIV at the first antenatal care visit, the percentage of HIV-infected pregnant women receiving adequate prophylaxis or combination antiretroviral therapy in pregnancy, and the percentage of newborns exposed to HIV in pregnancy receiving an HIV diagnosis eight weeks postpartum. The Consolidated Framework for Implementation Research (CFIR) will guide collection and analysis of qualitative data on implementation process. This study is a pragmatic trial that has the potential benefit of improving maternal and infant outcomes by reducing drop-offs along the pMTCT cascade. The SAIA intervention is designed to provide simple tools to guide decision-making for pMTCT program staff at the facility level, and to identify low cost, contextually appropriate pMTCT improvement strategies. ClinicalTrials.gov NCT02023658.

  15. A comparison of parent satisfaction in an open-bay and single-family room neonatal intensive care unit.

    PubMed

    Stevens, Dennis C; Helseth, Carol C; Khan, M Akram; Munson, David P; Reid, E J

    2011-01-01

    The purpose of this research was to test the hypothesis that parental satisfaction with neonatal intensive care is greater in a single-family room facility as compared with a conventional open-bay neonatal intensive care unit (NICU). This investigation was a prospective cohort study comparing satisfaction survey results for parents who responded to a commercially available parent NICU satisfaction survey following the provision of NICU care in open-bay and single-family room facilities. A subset of 16 items indicative of family-centered care was also computed and compared for these two NICU facilities. Parents whose babies received care in the single-family room facility expressed significantly improved survey responses in regard to the NICU environment, overall assessment of care, and total survey score than did parents of neonates in the open-bay facility. With the exception of the section on nursing in which scores in both facilities were high, nonsignificant improvement in median scores for the sections on delivery, physicians, discharge planning, and personal issues were noted. The total median item score for family-centered care was significantly greater in the single-family room than the open-bay facility. Parental satisfaction with care in the single-family room NICU was improved in comparison with the traditional open-bay NICU. The single-family room environment appears more conducive to the provision of family-centered care. Improved parental satisfaction with care and the potential for enhanced family-centered care need to be considered in decisions made regarding the configuration of NICU facilities in the future.

  16. HIV Testing, HIV Positivity, and Linkage and Referral Services in Correctional Facilities in the United States, 2009–2013

    PubMed Central

    Seth, Puja; Figueroa, Argelia; Wang, Guoshen; Reid, Laurie; Belcher, Lisa

    2016-01-01

    Background Because of health disparities, incarcerated persons are at higher risk for multiple health issues, including HIV. Correctional facilities have an opportunity to provide HIV services to an underserved population. This article describes Centers for Disease Control and Prevention (CDC)–funded HIV testing and service delivery in correctional facilities. Methods Data on HIV testing and service delivery were submitted to CDC by 61 health department jurisdictions in 2013. HIV testing, HIV positivity, receipt of test results, linkage, and referral services were described, and differences across demographic characteristics for linkage and referral services were assessed. Finally, trends were examined for HIV testing, HIV positivity, and linkage from 2009 to 2013. Results Of CDC-funded tests in 2013 among persons 18 years and older, 254,719 (7.9%) were conducted in correctional facilities. HIV positivity was 0.9%, and HIV positivity for newly diagnosed persons was 0.3%. Blacks accounted for the highest percentage of HIV-infected persons (1.3%) and newly diagnosed persons (0.5%). Only 37.9% of newly diagnosed persons were linked within 90 days; 67.5% were linked within any time frame; 49.7% were referred to partner services; and 45.2% were referred to HIV prevention services. There was a significant percent increase in HIV testing, overall HIV positivity, and linkage from 2009 to 2013. However, trends were stable for newly diagnosed persons. Conclusions Identification of newly diagnosed persons in correctional facilities has remained stable from 2009 to 2013. Correctional facilities seem to be reaching blacks, likely due to higher incarceration rates. The current findings indicate that improvements are needed in HIV testing strategies, service delivery during incarceration, and linkage to care postrelease. PMID:26462190

  17. Operational flow visualization techniques in the Langley Unitary Plan Wind Tunnel

    NASA Technical Reports Server (NTRS)

    Corlett, W. A.

    1982-01-01

    The unitary plan wind tunnel (UPWT) uses in daily operation are shown. New ideas for improving the quality of established flow visualization methods are developed and programs on promising new flow visualization techniques are pursued. The unitary plan wind tunnel is a supersonic facility, referred to as a production facility, although the majority of tests are inhouse basic research investigations. The facility has two 4 ft. by 4 ft. test sections which span a Mach range from 1.5 to 4.6. The cost of operation is about $10 per minute. Problems are the time required for a flow visualization test setup and investigation costs and the ability to obtain consistently repeatable results. Examples of sublimation, vapor screen, oil flow, minitufts, schlieren, and shadowgraphs taken in UPWT are presented. All tests in UPWT employ one or more of the flow visualization techniques.

  18. Safety Assurances at Space Test Centres: Lessons Learned

    NASA Astrophysics Data System (ADS)

    Alarcon Ruiz, Raul; O'Neil, Sean; Valls, Rafel Prades

    2010-09-01

    The European Space Agency’s(ESA) experts in quality, cleanliness and contamination control, safety, test facilities and test methods have accumulated valuable experience during the performance of dedicated audits of space test centres in Europe over a period of 10 years. This paper is limited to a summary of the safety findings and provides a valuable reference to the lessons learned, identifying opportunities for improvement in the areas of risk prevention measures associated to the safety of all test centre personnel, the test specimen, the test facilities and associated infrastructure. Through the analysis of the audit results the authors present what are the main lessons learned, and conclude how an effective safety management system will contribute to successful test campaigns and have a positive impact on the cost and schedule of space projects.

  19. Tritium protective clothing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fuller, T. P.; Easterly, C. E.

    Occupational exposures to radiation from tritium received at present nuclear facilities and potential exposures at future fusion reactor facilities demonstrate the need for improved protective clothing. Important areas relating to increased protection factors of tritium protective ventilation suits are discussed. These areas include permeation processes of tritium through materials, various tests of film permeability, selection and availability of suit materials, suit designs, and administrative procedures. The phenomenological nature of film permeability calls for more standardized and universal test methods, which would increase the amount of directly useful information on impermeable materials. Improvements in suit designs could be expedited and bettermore » communicated to the health physics community by centralizing devlopmental equipment, manpower, and expertise in the field of tritium protection to one or two authoritative institutions.« less

  20. Development and perceived effects of an educational programme on quality and safety in medication handling in residential facilities.

    PubMed

    Mygind, Anna; El-Souri, Mira; Rossing, Charlotte; Thomsen, Linda Aagaard

    2018-04-01

    To develop and test an educational programme on quality and safety in medication handling for staff in residential facilities for the disabled. The continuing pharmacy education instructional design model was used to develop the programme with 22 learning objectives on disease and medicines, quality and safety, communication and coordination. The programme was a flexible, modular seven + two days' course addressing quality and safety in medication handling, disease and medicines, and medication supervision and reconciliation. The programme was tested in five Danish municipalities. Municipalities were selected based on their application for participation; each independently selected a facility for residents with mental and intellectual disabilities, and a facility for residents with severe mental illnesses. Perceived effects were measured based on a questionnaire completed by participants before and after the programme. Effects on motivation and confidence as well as perceived effects on knowledge, skills and competences related to medication handling, patient empowerment, communication, role clarification and safety culture were analysed conducting bivariate, stratified analyses and test for independence. Of the 114 participants completing the programme, 75 participants returned both questionnaires (response rate = 66%). Motivation and confidence regarding quality and safety in medication handling significantly improved, as did perceived knowledge, skills and competences on 20 learning objectives on role clarification, safety culture, medication handling, patient empowerment and communication. The programme improved staffs' motivation and confidence and their perceived ability to handle residents' medication safely through improved role clarification, safety culture, medication handling and patient empowerment and communication skills. © 2017 Royal Pharmaceutical Society.

  1. Women's Preferences for Place of Delivery in Rural Tanzania: A Population-Based Discrete Choice Experiment

    PubMed Central

    Paczkowski, Magdalena; Mbaruku, Godfrey; de Pinho, Helen; Galea, Sandro

    2009-01-01

    Objectives. We fielded a population-based discrete choice experiment (DCE) in rural western Tanzania, where only one third of women deliver children in a health facility, to evaluate health-system factors that influence women's delivery decisions. Methods. Women were shown choice cards that described 2 hypothetical health centers by means of 6 attributes (distance, cost, type of provider, attitude of provider, drugs and equipment, free transport). The women were then asked to indicate which of the 2 facilities they would prefer to use for a future delivery. We used a hierarchical Bayes procedure to estimate individual and mean utility parameters. Results. A total of 1203 women completed the DCE. The model showed good predictive validity for actual facility choice. The most important facility attributes were a respectful provider attitude and availability of drugs and medical equipment. Policy simulations suggested that if these attributes were improved at existing facilities, the proportion of women preferring facility delivery would rise from 43% to 88%. Conclusions. In regions in which attended delivery rates are low despite availability of primary care facilities, policy experiments should test the effect of targeted quality improvements on facility use. PMID:19608959

  2. Innovations at a European Planetary Simulation Facility

    NASA Astrophysics Data System (ADS)

    Merrison, J.; Iversen, J. J.; Alois, S.; Rasmussen, K. R.

    2017-09-01

    This unique and recently improved planetary simulation facility is capable of re-creating extreme terrestrial, Martian and other planetary environments. It is supported by EU activities including Europlanet 2020 RI and a volcanology network VERTIGO. It is also used as a test facility by ESA for the forthcoming ExoMars 2020 mission. Specifically it is capable of recreating the key physical parameters such as temperature, pressure (gas composition), wind flow and importantly the suspension/transport of dust or sand particulates. This facility is available both to the scientific and Industrial community. The latest research and networking activities will be presented.

  3. A forecast of new test capabilities using Magnetic Suspension and Balance Systems

    NASA Technical Reports Server (NTRS)

    Lawing, Pierce L.; Johnson, William G., Jr.

    1988-01-01

    This paper outlines the potential of Magnetic Suspension and Balance System (MSBS) technology to solve existing problems related to support interference in wind tunnels. Improvement of existing test techniques and exciting new techniques are envisioned as a result of applying MSBS. These include improved data accuracy, dynamic stability testing, two-body/stores release testing, and pilot/designer-in-the-loop tests. It also discusses the use of MSBS for testing exotic configurations such as hybrid hypersonic vehicles. A new facility concept that combines features of ballistic tubes, magnetic suspension, and cryogenic tunnels is described.

  4. Improved control strategy for wind-powered refrigerated storage of apples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baldwin, J.D.C.; Vaughan, D.H.

    1981-01-01

    A refrigerated apple storage facility was constructed at the VPI and SU Horticultural Research Farm in Blacksburg, Virginia and began operation in March 1978. The system included a 10-kW electric wind generator, electrical battery storage, thermal (ice) storage, and auxiliary power. The need for an improved control system for the VPI and SU system was determined from tests on the individual components and in situ performance tests. The results of these tests formed the basis for an improved control strategy to improve the utilization of available wind energy and reduce the need for auxiliary power while maintaining an adequate applemore » storage environment.« less

  5. The availability and functional status of focused antenatal care laboratory services at public health facilities in Addis Ababa, Ethiopia.

    PubMed

    Desalegn, Daniel Melese; Abay, Serebe; Taye, Bineyam

    2016-08-11

    Provision of quality laboratory services is an essential aspect of a promoting safe motherhood and better outcomes for newborn. Therefore; this study was intended to assess status of focused antenatal care (FANC) laboratory services at public health facilities in Addis Ababa, Ethiopia. Institution based, descriptive cross-sectional study was conducted from April to May 2015. The study included 13 randomly selected health facilities and 13 purposively selected laboratory service providers. The status of FANC laboratory service was assessed by using pre-tested structured questionnaire and observation checklist. The study supplemented with qualitative data through in-depth interview of laboratory service providers. The quantitative data were coded and analysed by using SPSS Version 20 software and qualitative data was transcribed, coded, categorized and thematically analysed by the principal investigator. Only 5 (38.5 %) out of 13 visited health facilities reported the availability of all types of basic FANC laboratory investigations. Comparing the availability of individual tests in the study facilities, urine dipstick, urine microscopy and stool examination were available in all institutions. However, only 7 (53.8 %) of the health facilities reported the availability of hepatitis B virus screening test. Rapid syphilis (RPR) test was found in 10 (76.9 %) facilities. All laboratory facilities had at least one or more basic FANC laboratory tests interruption for more than a day within the last 1 year due to shortage of reagent and electric power disruption. Majority of the health facilities reported incomplete provision of FANC laboratory investigations. Laboratory supply shortage and electric power disruption were the facilities' major challenge to screen pregnant women for pregnancy related health conditions. Since such conditions may affect the outcome of pregnancy, therefore extensive efforts should be targeted to avoid services interruption by taking improvement measures including the fulfilment of all FANC laboratory resources.

  6. Recommendations for Health Monitoring and Reporting for Zebrafish Research Facilities

    PubMed Central

    Crim, Marcus J.; Lieggi, Christine

    2016-01-01

    Abstract The presence of subclinical infection or clinical disease in laboratory zebrafish may have a significant impact on research results, animal health and welfare, and transfer of animals between institutions. As use of zebrafish as a model of disease increases, a harmonized method for monitoring and reporting the health status of animals will facilitate the transfer of animals, allow institutions to exclude diseases that may negatively impact their research programs, and improve animal health and welfare. All zebrafish facilities should implement a health monitoring program. In this study, we review important aspects of a health monitoring program, including choice of agents, samples for testing, available testing methodologies, housing and husbandry, cost, test subjects, and a harmonized method for reporting results. Facilities may use these recommendations to implement their own health monitoring program. PMID:26991393

  7. A research study for the preliminary definition of an aerophysics free-flight laboratory facility

    NASA Technical Reports Server (NTRS)

    Canning, Thomas N.

    1988-01-01

    A renewed interest in hypervelocity vehicles requires an increase in the knowledge of aerodynamic phenomena. Tests conducted with ground-based facilities can be used both to better understand the physics of hypervelocity flight, and to calibrate and validate computer codes designed to predict vehicle performance in the hypervelocity environment. This research reviews the requirements for aerothermodynamic testing and discusses the ballistic range and its capabilities. Examples of the kinds of testing performed in typical high performance ballistic ranges are described. We draw heavily on experience obtained in the ballistics facilities at NASA Ames Research Center, Moffett Field, California. Prospects for improving the capabilities of the ballistic range by using advanced instrumentation are discussed. Finally, recent developments in gun technology and their application to extend the capability of the ballistic range are summarized.

  8. NASA Langley Low Speed Aeroacoustic Wind Tunnel: Background Noise and Flow Survey Results Prior to FY05 Construction of Facilities Modifications

    NASA Technical Reports Server (NTRS)

    Booth, Earl R., Jr.; Henderson, Brenda S.

    2005-01-01

    The NASA Langley Research Center Low Speed Aeroacoustic Wind Tunnel is a premier facility for model-scale testing of jet noise reduction concepts at realistic flow conditions. However, flow inside the open jet test section is less than optimum. A Construction of Facilities project, scheduled for FY 05, will replace the flow collector with a new design intended to reduce recirculation in the open jet test section. The reduction of recirculation will reduce background noise levels measured by a microphone array impinged by the recirculation flow and will improve flow characteristics in the open jet tunnel flow. In order to assess the degree to which this modification is successful, background noise levels and tunnel flow are documented, in order to establish a baseline, in this report.

  9. Improvements To Progressive Wave Tube Performance Through Closed-Loop Control

    NASA Technical Reports Server (NTRS)

    Rizzi, Stephen A.

    2000-01-01

    This report documents recent improvements to the acoustic and thermal control systems of the Thermal Acoustic Fatigue Apparatus (TAFA), a progressive wave tube test facility at the NASA Langley Research Center, Hampton, Virginia. A brief summary of past acoustic performance is given first to serve as a basis for comparison with the new performance data using a multiple-input, closed-loop, narrow-band controller. Performance data in the form of test section acoustic power spectral densities and coherence are presented in three of six facility configurations for a variety of input spectra. Tested spectra include uniform, two cases of pink noise, three cases of narrow-band random, a simulated launch payload bay environment for an expendable launch vehicle, and a simulated external acoustic load for the aft section of a reusable launch vehicle. In addition, a new closed-loop temperature controller and thermocouple data acquisition system are described.

  10. Popping a Hole in High-Speed Pursuits

    NASA Technical Reports Server (NTRS)

    2005-01-01

    NASA s Plum Brook Station, a 6,400-acre, remote test installation site for Glenn Research Center, houses unique, world-class test facilities, including the world s largest space environment simulation chamber and the world s only laboratory capable of full-scale rocket engine firings and launch vehicle system level tests at high-altitude conditions. Plum Brook Station performs complex and innovative ground tests for the U.S. Government (civilian and military), the international aerospace community, as well as the private sector. Popping a Hole in High-Speed Pursuits Recently, Plum Brook Station s test facilities and NASA s engineering experience were combined to improve a family of tire deflating devices (TDDs) that helps law enforcement agents safely, simply, and successfully stop fleeing vehicles in high-speed pursuit

  11. Development of an Uncertainty Model for the National Transonic Facility

    NASA Technical Reports Server (NTRS)

    Walter, Joel A.; Lawrence, William R.; Elder, David W.; Treece, Michael D.

    2010-01-01

    This paper introduces an uncertainty model being developed for the National Transonic Facility (NTF). The model uses a Monte Carlo technique to propagate standard uncertainties of measured values through the NTF data reduction equations to calculate the combined uncertainties of the key aerodynamic force and moment coefficients and freestream properties. The uncertainty propagation approach to assessing data variability is compared with ongoing data quality assessment activities at the NTF, notably check standard testing using statistical process control (SPC) techniques. It is shown that the two approaches are complementary and both are necessary tools for data quality assessment and improvement activities. The SPC approach is the final arbiter of variability in a facility. Its result encompasses variation due to people, processes, test equipment, and test article. The uncertainty propagation approach is limited mainly to the data reduction process. However, it is useful because it helps to assess the causes of variability seen in the data and consequently provides a basis for improvement. For example, it is shown that Mach number random uncertainty is dominated by static pressure variation over most of the dynamic pressure range tested. However, the random uncertainty in the drag coefficient is generally dominated by axial and normal force uncertainty with much less contribution from freestream conditions.

  12. Aero-Thermal Calibration of the NASA Glenn Icing Research Tunnel (2004 and 2005 Tests)

    NASA Technical Reports Server (NTRS)

    Arrington, E. Allen; Pastor, Christine M.; Gonsalez, Jose C.; Curry, Monroe R., III

    2010-01-01

    A full aero-thermal calibration of the NASA Glenn Icing Research Tunnel was completed in 2004 following the replacement of the inlet guide vanes upstream of the tunnel drive system and improvement to the facility total temperature instrumentation. This calibration test provided data used to fully document the aero-thermal flow quality in the IRT test section and to construct calibration curves for the operation of the IRT. The 2004 test was also the first to use the 2-D RTD array, an improved total temperature calibration measurement platform.

  13. Development of airframe design technology for crashworthiness.

    NASA Technical Reports Server (NTRS)

    Kruszewski, E. T.; Thomson, R. G.

    1973-01-01

    This paper describes the NASA portion of a joint FAA-NASA General Aviation Crashworthiness Program leading to the development of improved crashworthiness design technology. The objectives of the program are to develop analytical technology for predicting crashworthiness of structures, provide design improvements, and perform full-scale crash tests. The analytical techniques which are being developed both in-house and under contract are described, and typical results from these analytical programs are shown. In addition, the full-scale testing facility and test program are discussed.

  14. Knowledge of tuberculosis (TB) and human immunodeficiency virus (HIV) and perception about provider initiated HIV testing and counselling among TB patients attending health facilities in Harar town, Eastern Ethiopia.

    PubMed

    Seyoum, Ayichew; Legesse, Mengistu

    2013-02-08

    Tuberculosis (TB) and Human Immunodeficiency Virus (HIV) co-infection is one of the major health problems in Ethiopia. The national TB and HIV control guideline in Ethiopia recommends provider initiated HIV testing and counselling (PITC) as a routine care for TB patients. However, the impact of this approach on the treatment seeking of TB patients has not been well studied. In this study, we assessed knowledge of TB and HIV, and perception about PITC among TB patients attending health facilities in Harar town, Eastern Ethiopia. In a health facilities based cross-sectional study, a total of 415 study participants were interviewed about knowledge of TB and HIV as well as the impact of HIV testing on their treatment seeking behavior using a semi-structured questionnaires. Multivariable logistic regression analysis showed the association of distance > 10 km from health facility [adjusted odds ratio (AOR)=0.48, 95% CI: 0.24 - 0.97, P=0.042] with low knowledge of TB. Distance > 10 km from health facility (AOR= 0.12, 95% CI: 0.06 -0.23, P < 0.001) was also associated with low knowledge of HIV testing. Delay in treatment seeking was associated with female participants (AOR = 0.11, 95% CI: 0.05-0.25, <0.001), single marital status (AOR =0.001, 95% CI: 0.00 - 0.01, P< 0.001) and distance > 10 km from health facility (AOR =0.46, 95% CI: 0.28 - 0.75, P=0.002). Most of the study participants (70%) believed that there is no association between TB and HIV/AIDS. On the other hand, two thirds (66.5%) of the participants thought that HIV testing has importance for TB patients. However, the majority (81.6%) of the study participants in the age category less than 21 years believed that fear of PITC could cause delay in treatment seeking. The study showed the association of low knowledge of the study participants about TB and HIV testing with distance > 10 km from health facility. Study participants in the age category less than 21 years thought that fear of PITC could cause treatment delay of TB patients. Hence, emphasis should be given to improve knowledge of TB and HIV among residents far away from health facility, and attention also needs to be given to improve the perception of individuals in the age group less than 21 years about PITC in the present study area.

  15. Department of the Navy Justification of Estimates for Fiscal Year 1983 Submitted to Congress February 1982. Research, Development, Test and Evaluation: Research, Development, Test and Evaluation, Navy.

    DTIC Science & Technology

    1982-02-01

    Improvements to and Construction of Government -Owned Facilities Funded by RDT&E -------------------- 57 Section 8: Project Data for Construction at... Government -Owned Facilities Funded by RDT&E --------------------------. . Section 9: Flight Simulator Programs...653,427 936.167 29 63202N AVIONICS 2 3,314 3,745 3,622 10,342 U 407 26 632n3N A0V HELICOPTER DEV 2 4,577 4,790 U 27 63207N ENVIRONENTAL APPLICATIONS 2

  16. Runway Incursion Prevention System Testing at the Wallops Flight Facility

    NASA Technical Reports Server (NTRS)

    Jones, Denise R.

    2005-01-01

    A Runway Incursion Prevention System (RIPS) integrated with a Synthetic Vision System concept (SVS) was tested at the Reno/Tahoe International Airport (RNO) and Wallops Flight Facility (WAL) in the summer of 2004. RIPS provides enhanced surface situational awareness and alerts of runway conflicts in order to prevent runway incidents while also improving operational capability. A series of test runs was conducted using a Gulfstream-V (G-V) aircraft as the test platform and a NASA test aircraft and a NASA test van as incurring traffic. The purpose of the study, from the RIPS perspective, was to evaluate the RIPS airborne incursion detection algorithms and associated alerting and airport surface display concepts, focusing on crossing runway incursion scenarios. This paper gives an overview of the RIPS, WAL flight test activities, and WAL test results.

  17. Using pay for performance incentives (P4P) to improve management of suspected malaria fevers in rural Kenya: a cluster randomized controlled trial.

    PubMed

    Menya, Diana; Platt, Alyssa; Manji, Imran; Sang, Edna; Wafula, Rebeccah; Ren, Jing; Cheruiyot, Olympia; Armstrong, Janice; Neelon, Brian; O'Meara, Wendy Prudhomme

    2015-10-16

    Inappropriate treatment of non-malaria fevers with artemisinin-based combination therapies (ACTs) is a growing concern, particularly in light of emerging artemisinin resistance, but it is a behavior that has proven difficult to change. Pay for performance (P4P) programs have generated interest as a mechanism to improve health service delivery and accountability in resource-constrained health systems. However, there has been little experimental evidence to establish the effectiveness of P4P in developing countries. We tested a P4P strategy that emphasized parasitological diagnosis and appropriate treatment of suspected malaria, in particular reduction of unnecessary consumption of ACTs. A random sample of 18 health centers was selected and received a refresher workshop on malaria case management. Pre-intervention baseline data was collected from August to September 2012. Facilities were subsequently randomized to either the comparison (n = 9) or intervention arm (n = 9). Between October 2012 and November 2013, facilities in the intervention arm received quarterly incentive payments based on seven performance indicators. Incentives were for use by facilities rather than as payments to individual providers. All non-pregnant patients older than 1 year of age who presented to a participating facility and received either a malaria test or artemether-lumefantrine (AL) were eligible to be included in the analysis. Our primary outcome was prescription of AL to patients with a negative malaria diagnostic test (n = 11,953). Our secondary outcomes were prescription of AL to patients with laboratory-confirmed malaria (n = 2,993) and prescription of AL to patients without a malaria diagnostic test (analyzed at the cluster level, n = 178 facility-months). In the final quarter of the intervention period, the proportion of malaria-negative patients in the intervention arm who received AL was lower than in the comparison arm (7.3% versus 10.9%). The improvement from baseline to quarter 4 in the intervention arm was nearly three times that of the comparison arm (ratio of adjusted odds ratios for baseline to quarter 4 = 0.36, 95% CI: 0.24-0.57). The rate of prescription of AL to patients without a test was five times lower in the intervention arm (adjusted incidence rate ratio = 0.18, 95% CI: 0.07-0.48). Prescription of AL to patients with confirmed infection was not significantly different between the groups over the study period. Facility-based incentives coupled with training may be more effective than training alone and could complement other quality improvement approaches. This study was registered with ClinicalTrials.gov (NCT01809873) on 11 March 2013.

  18. Ventures in Community Improvement (VICI): Findings from a Four-Site Replication Initiative, 1984-1987.

    ERIC Educational Resources Information Center

    Levin, Laurie; And Others

    Ventures in Community Improvement (VICI) is a program that provides intensive training in construction skills to disadvantaged youth and at the same time allows them to produce tangible improvements in housing and public facilities in their own low-income communities. The model was tested twice previously, once in an eight-state demonstration that…

  19. Changes in Patient Sorting to Nursing Homes under Public Reporting: Improved Patient Matching or Provider Gaming?

    PubMed Central

    Werner, Rachel M; Konetzka, R Tamara; Stuart, Elizabeth A; Polsky, Daniel

    2011-01-01

    Objective To test whether public reporting in the setting of postacute care in nursing homes results in changes in patient sorting. Data Sources/Study Setting All postacute care admissions from 2001 to 2003 in the nursing home Minimum Data Set. Study Design We test changes in patient sorting (or the changes in the illness severity of patients going to high- versus low-scoring facilities) when public reporting was initiated in nursing homes in 2002. We test for changes in sorting with respect to pain, delirium, and walking and then examine the potential roles of cream skimming and downcoding in changes in patient sorting. We use a difference-in-differences framework, taking advantage of the variation in the launch of public reporting in pilot and nonpilot states, to control for underlying trends in patient sorting. Principal Findings There was a significant change in patient sorting with respect to pain after public reporting was initiated, with high-risk patients being more likely to go to high-scoring facilities and low-risk patients more likely to go to low-scoring facilities. There was also an overall decrease in patient risk of pain with the launch of public reporting, which may be consistent with changes in documentation of pain levels (or downcoding). There was no significant change in sorting for delirium or walking. Conclusions Public reporting of nursing home quality improves matching of high-risk patients to high-quality facilities. However, efforts should be made to reduce the incentives for downcoding by nursing facilities. PMID:21105869

  20. Availability and Quality of Family Planning Services in the Democratic Republic of the Congo: High Potential for Improvement.

    PubMed

    Mpunga, Dieudonné; Lumbayi, J P; Dikamba, Nelly; Mwembo, Albert; Ali Mapatano, Mala; Wembodinga, Gilbert

    2017-06-27

    To determine the availability and quality of family planning services within health facilities throughout the Democratic Republic of the Congo (DRC). Data were collected for the cross-sectional study from April 2014 to June 2014 by the Ministry of Public Health. A total of 1,568 health facilities that reported data to the National Health Information System were selected by multistage random sampling in the 11 provinces of the DRC existing at that time. Data were collected through interviews, document review, and direct observation. Two dependent variables were measured: availability of family planning services (consisting of a room for services, staff assigned to family planning, and evidence of client use of family planning) and quality of family planning services (assessed as "high" if the facility had at least 1 trained staff member, family planning service delivery guidelines, at least 3 types of methods, and a sphygmomanometer, or "low" if the facility did not meet any of these 4 criteria). Pearson's chi-square test and odds ratios (ORs) were used to test for significant associations, using the alpha significance level of .05. We successfully surveyed 1,555 facilities (99.2%) of those included in the sample. One in every 3 facilities (33%) offered family planning services as assessed by the index of availability, of which 20% met all 4 criteria for providing high-quality services. Availability was greatest at the highest level of the health system (hospitals) and decreased incrementally with each health system level, with disparities between provinces and urban and rural areas. Facilities in urban areas were more likely than in rural areas to meet the standard for high-quality services ( P <.001). Public facilities were less likely than private facilities to have high-quality services ( P =.02). Among all 1,555 facilities surveyed, 14% had at least 3 types of methods available at the time of the survey; the most widely available methods were male condoms, combined oral contraceptive pills, and progestin-only injectable contraceptives. Availability and quality of family planning services in health facilities in the DRC remain low, with inequitable distribution of services throughout the country. To improve access to and use of family planning, efforts should focus on improving availability and quality at lower health system levels and in rural areas where the majority of the population lives. © Mpunga et al.

  1. Factors affecting acceptance of provider-initiated HIV testing and counseling services among outpatient clients in selected health facilities in Harar Town, Eastern Ethiopia.

    PubMed

    Abdurahman, Sami; Seyoum, Berhanu; Oljira, Lemessa; Weldegebreal, Fitsum

    2015-01-01

    To improve the slow uptake of HIV counseling and testing, the World Health Organization (WHO) and the Joint United Nations Programme on HIV/AIDS (UNAIDS) have developed draft guidelines on provider-initiated testing and counseling (PITC). Both in low- and high-income countries, mainly from outpatient clinics and tuberculosis settings, indicates that the direct offer of HIV testing by health providers can result in significant improvements in test uptake. In Ethiopia, there were limited numbers of studies conducted regarding PITC in outpatient clinics. Therefore, in this study, we have assessed the factors affecting the acceptance of PITC among outpatient clients in selected health facilities in Harar, Harari Region State, Ethiopia. Institutional-based, cross-sectional quantitative and qualitative studies were conducted from February 12-30, 2011 in selected health facilities in Harar town, Harari Region State, Ethiopia. The study participants were recruited from the selected health facilities of Harar using a systematic random sampling technique. The collected data were double entered into a data entry file using Epi Info version 3.5.1. The data were transferred to SPSS software version 16 and analyzed according to the different variables. A total of 362 (70.6%) clients accepted PITC, and only 39.4% of clients had heard of PITC in the outpatient department service. Age, occupation, marital status, anyone who wanted to check their HIV status, and the importance of PITC were the variables that showed significant associations with the acceptance of PITC upon bivariate and multivariate analyses. The main reasons given for not accepting the tests were self-trust, not being at risk for HIV, not being ready, needing to consult their partners, a fear of the results, a shortage of staff, a busy work environment, a lack of private rooms, and a lack of refresher training, which were identified as the main barriers for PITC. There is evidence of the relatively increased acceptability of PITC services by outpatient department clients. A program needs to be strengthened to enhance the use of PITC; the Ministry of Health, Regional Health Bureau, and other responsible bodies - including health facilities - should design and strengthen information education and communication/behavioral change and communication interventions and promote activities related to PITC and HIV counseling and testing in both health facilities and the community at large.

  2. Physics and technology in the ion-cyclotron range of frequency on Tore Supra and TITAN test facility: implication for ITER

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Litaudon, X; Bernard, J. M.; Colas, L.

    2013-01-01

    To support the design of an ITER ion-cyclotron range of frequency heating (ICRH) system and to mitigate risks of operation in ITER, CEA has initiated an ambitious Research & Development program accompanied by experiments on Tore Supra or test-bed facility together with a significant modelling effort. The paper summarizes the recent results in the following areas: Comprehensive characterization (experiments and modelling) of a new Faraday screen concept tested on the Tore Supra antenna. A new model is developed for calculating the ICRH sheath rectification at the antenna vicinity. The model is applied to calculate the local heat flux on Toremore » Supra and ITER ICRH antennas. Full-wave modelling of ITER ICRH heating and current drive scenarios with the EVE code. With 20 MW of power, a current of 400 kA could be driven on axis in the DT scenario. Comparison between DT and DT(3He) scenario is given for heating and current drive efficiencies. First operation of CW test-bed facility, TITAN, designed for ITER ICRH components testing and could host up to a quarter of an ITER antenna. R&D of high permittivity materials to improve load of test facilities to better simulate ITER plasma antenna loading conditions.« less

  3. Measuring Quality Gaps in TB Screening in South Africa Using Standardised Patient Analysis

    PubMed Central

    Christian, Carmen S.; Gerdtham, Ulf-G.; Hompashe, Dumisani; Smith, Anja; Burger, Ronelle

    2018-01-01

    This is the first multi-district Standardised Patient (SP) study in South Africa. It measures the quality of TB screening at primary healthcare (PHC) facilities. We hypothesise that TB screening protocols and best practices are poorly adhered to at the PHC level. The SP method allows researchers to observe how healthcare providers identify, test and advise presumptive TB patients, and whether this aligns with clinical protocols and best practice. The study was conducted at PHC facilities in two provinces and 143 interactions at 39 facilities were analysed. Only 43% of interactions resulted in SPs receiving a TB sputum test and being offered an HIV test. TB sputum tests were conducted routinely (84%) while HIV tests were offered less frequently (47%). Nurses frequently neglected to ask SPs whether their household contacts had confirmed TB (54%). Antibiotics were prescribed without taking temperatures in 8% of cases. The importance of returning to the facility to receive TB test results was only explained in 28%. The SP method has highlighted gaps in clinical practice, signalling missed opportunities. Early detection of sub-optimal TB care is instrumental in decreasing TB-related morbidity and mortality. The findings provide the rationale for further quality improvement work in TB management. PMID:29649095

  4. James Webb Space Telescope (JWST) Integrated Science Instruments Module (ISIM) Cryo-Vacuum (CV) Test Campaign Summary

    NASA Technical Reports Server (NTRS)

    Yew, Calinda; Whitehouse, Paul; Lui, Yan; Banks, Kimberly

    2016-01-01

    JWST Integrated Science Instruments Module (ISIM) has completed its system-level testing program at the NASA Goddard Space Flight Center (GSFC). In March 2016, ISIM was successfully delivered for integration with the Optical Telescope Element (OTE) after the successful verification of the system through a series of three cryo-vacuum (CV) tests. The first test served as a risk reduction test; the second test provided the initial verification of the fully-integrated flight instruments; and the third test verified the system in its final flight configuration. The complexity of the mission has generated challenging requirements that demand highly reliable system performance and capabilities from the Space Environment Simulator (SES) vacuum chamber. As JWST progressed through its CV testing campaign, deficiencies in the test configuration and support equipment were uncovered from one test to the next. Subsequent upgrades and modifications were implemented to improve the facility support capabilities required to achieve test requirements. This paper: (1) provides an overview of the integrated mechanical and thermal facility systems required to achieve the objectives of JWST ISIM testing, (2) compares the overall facility performance and instrumentation results from the three ISIM CV tests, and (3) summarizes lessons learned from the ISIM testing campaign.

  5. Life-Cycle Assessments of Selected NASA Ground-Based Test Facilities

    NASA Technical Reports Server (NTRS)

    Sydnor, George Honeycutt

    2012-01-01

    In the past two years, two separate facility-specific life cycle assessments (LCAs) have been performed as summer student projects. The first project focused on 13 facilities managed by NASA s Aeronautics Test Program (ATP), an organization responsible for large, high-energy ground test facilities that accomplish the nation s most advanced aerospace research. A facility inventory was created for each facility, and the operational-phase carbon footprint and environmental impact were calculated. The largest impacts stemmed from electricity and natural gas used directly at the facility and to generate support processes such as compressed air and steam. However, in specialized facilities that use unique inputs like R-134a, R-14, jet fuels, or nitrogen gas, these sometimes had a considerable effect on the facility s overall environmental impact. The second LCA project was conducted on the NASA Ames Arc Jet Complex and also involved creating a facility inventory and calculating the carbon footprint and environmental impact. In addition, operational alternatives were analyzed for their effectiveness at reducing impact. Overall, the Arc Jet Complex impact is dominated by the natural-gas fired boiler producing steam on-site, but alternatives were provided that could reduce the impact of the boiler operation, some of which are already being implemented. The data and results provided by these LCA projects are beneficial to both the individual facilities and NASA as a whole; the results have already been used in a proposal to reduce carbon footprint at Ames Research Center. To help future life cycle projects, several lessons learned have been recommended as simple and effective infrastructure improvements to NASA, including better utility metering and data recording and standardization of modeling choices and methods. These studies also increased sensitivity to and appreciation for quantifying the impact of NASA s activities.

  6. Wind-tunnel simulation of store jettison with the aid of magnetic artificial gravity

    NASA Technical Reports Server (NTRS)

    Stephens, T.; Adams, R.

    1972-01-01

    A method employed in the simulation of jettison of stores from aircraft involving small scale wind-tunnel drop tests from a model of the parent aircraft is described. Proper scaling of such experiments generally dictates that the gravitational acceleration should ideally be a test variable. A method of introducing a controllable artificial component of gravity by magnetic means has been proposed. The use of a magnetic artificial gravity facility based upon this idea, in conjunction with small scale wind-tunnel drop tests, would improve the accuracy of simulation. A review of the scaling laws as they apply to the design of such a facility is presented. The design constraints involved in the integration of such a facility with a wind tunnel are defined. A detailed performance analysis procedure applicable to such a facility is developed. A practical magnet configuration is defined which is capable of controlling the strength and orientation of the magnetic artificial gravity field in the vertical plane, thereby allowing simulation of store jettison from a diving or climbing aircraft. The factors involved in the choice between continuous or intermittent operation of the facility, and the use of normal or superconducting magnets, are defined.

  7. Improving children's nutrition environments: A survey of adoption and implementation of nutrition guidelines in recreational facilities

    PubMed Central

    2011-01-01

    Background Although the mandate of recreational facilities is to enhance well-being, many offer foods inconsistent with recommendations for healthy eating. Little is known regarding recreational facility food environments and how they might be improved, as few studies exist. The Alberta Nutrition Guidelines for Children and Youth (ANGCY) are intended to ensure access to healthy food choices in schools, childcare and recreational facilities. This study investigated awareness, adoption and implementation of the ANGCY among recreational facilities in Alberta, Canada, one year following their release. Methods A cross-sectional telephone survey was conducted from June - December, 2009 (n = 151) with managers of publicly funded recreational facilities that served food. The questionnaire included 10 closed and 7 open ended questions to assess the organizational priority for healthy eating, awareness, adoption and implementation of the ANGCY. Chi-squared tests examined quantitative variables, while qualitative data were analysed using directed content analysis. Greenhalgh's model of diffusion of complex innovations within health service organizations constituted the theoretical framework for the study. Results One half of respondents had heard of the ANGCY, however their knowledge of them was limited. Although 51% of facilities had made changes to improve the nutritional quality of foods offered in the past year, only a small fraction (11%) of these changes were motivated by the ANGCY. At the time of the survey, 14% of facilities had adopted the ANGCY and 6% had implemented them. Barriers to adoption and implementation were primarily related to perceived negative attributes of the ANGCY, the inner (organizational) context, and negative feedback received during the implementation process. Managers strongly perceived that implementing nutrition guidelines would limit their profit-making ability. Conclusions If fully adopted and implemented, the ANGCY have the potential to make a significant and sustained contribution to improving the recreational facility food environment, however one year following their release, awareness, adoption and implementation of the ANGCY remained low. A mandated policy approach could offer an efficacious, cost-effective means of improving the food environment within recreational facilities. PMID:21631946

  8. Modification of the Ames 40- by 80-foot wind tunnel for component acoustic testing for the second generation supersonic transport

    NASA Technical Reports Server (NTRS)

    Schmitz, F. H.; Allmen, J. R.; Soderman, P. T.

    1994-01-01

    The development of a large-scale anechoic test facility where large models of engine/airframe/high-lift systems can be tested for both improved noise reduction and minimum performance degradation is described. The facility development is part of the effort to investigate economically viable methods of reducing second generation high speed civil transport noise during takeoff and climb-out that is now under way in the United States. This new capability will be achieved through acoustic modifications of NASA's second largest subsonic wind tunnel: the 40-by 80-Foot Wind Tunnel at the NASA Ames Research Center. Three major items are addressed in the design of this large anechoic and quiet wind tunnel: a new deep (42 inch (107 cm)) test section liner, expansion of the wind tunnel drive operating envelope at low rpm to reduce background noise, and other promising methods of improving signal-to-noise levels of inflow microphones. Current testing plans supporting the U.S. high speed civil transport program are also outlined.

  9. Optical characterization of ultra-sensitive TES bolometers for SAFARI

    NASA Astrophysics Data System (ADS)

    Audley, Michael D.; de Lange, Gerhard; Gao, Jian-Rong; Khosropanah, Pourya; Mauskopf, Philip D.; Morozov, Dmitry; Trappe, Neil A.; Doherty, Stephen; Withington, Stafford

    2014-07-01

    We have characterized the optical response of prototype detectors for SAFARI, the far-infrared imaging spectrometer for the SPICA satellite. SAFARI's three bolometer arrays will image a 2'×2' field of view with spectral information over the wavelength range 34—210 μm. SAFARI requires extremely sensitive detectors (goal NEP ~ 0.2 aW/√Hz), with correspondingly low saturation powers (~5 fW), to take advantage of SPICA's cooled optics. We have constructed an ultra-low background optical test facility containing an internal cold black-body illuminator and have recently added an internal hot black-body source and a light-pipe for external illumination. We illustrate the performance of the test facility with results including spectral-response measurements. Based on an improved understanding of the optical throughput of the test facility we find an optical efficiency of 60% for prototype SAFARI detectors.

  10. Computational Simulations of the NASA Langley HyMETS Arc-Jet Facility

    NASA Technical Reports Server (NTRS)

    Brune, A. J.; Bruce, W. E., III; Glass, D. E.; Splinter, S. C.

    2017-01-01

    The Hypersonic Materials Environmental Test System (HyMETS) arc-jet facility located at the NASA Langley Research Center in Hampton, Virginia, is primarily used for the research, development, and evaluation of high-temperature thermal protection systems for hypersonic vehicles and reentry systems. In order to improve testing capabilities and knowledge of the test article environment, an effort is underway to computationally simulate the flow-field using computational fluid dynamics (CFD). A detailed three-dimensional model of the arc-jet nozzle and free-jet portion of the flow-field has been developed and compared to calibration probe Pitot pressure and stagnation-point heat flux for three test conditions at low, medium, and high enthalpy. The CFD model takes into account uniform pressure and non-uniform enthalpy profiles at the nozzle inlet as well as catalytic recombination efficiency effects at the probe surface. Comparing the CFD results and test data indicates an effectively fully-catalytic copper surface on the heat flux probe of about 10% efficiency and a 2-3 kpa pressure drop from the arc heater bore, where the pressure is measured, to the plenum section, prior to the nozzle. With these assumptions, the CFD results are well within the uncertainty of the stagnation pressure and heat flux measurements. The conditions at the nozzle exit were also compared with radial and axial velocimetry. This simulation capability will be used to evaluate various three-dimensional models that are tested in the HyMETS facility. An end-to-end aerothermal and thermal simulation of HyMETS test articles will follow this work to provide a better understanding of the test environment, test results, and to aid in test planning. Additional flow-field diagnostic measurements will also be considered to improve the modeling capability.

  11. Enhancing the usability of CRT displays in test flight monitoring

    NASA Astrophysics Data System (ADS)

    Granaas, Michael M.; Sredinski, Victoria E.

    1991-01-01

    Enhancing the usability of Mission Control Center (MCC) CRT displays stands to improve the quality, productivity, and safety of flight-test research at the NASA Ames-Dryden Flight Research Facility. The results of this research suggests that much can be done to assist the user and improve the quality of flight research through the enhancement of current displays. This research has applications to a variety of flight data monitoring displays.

  12. LLNL electro-optical mine detection program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Anderson, C.; Aimonetti, W.; Barth, M.

    1994-09-30

    Under funding from the Advanced Research Projects Agency (ARPA) and the US Marine Corps (USMC), Lawrence Livermore National Laboratory (LLNL) has directed a program aimed at improving detection capabilities against buried mines and munitions. The program has provided a national test facility for buried mines in arid environments, compiled and distributed an extensive data base of infrared (IR), ground penetrating radar (GPR), and other measurements made at that site, served as a host for other organizations wishing to make measurements, made considerable progress in the use of ground penetrating radar for mine detection, and worked on the difficult problem ofmore » sensor fusion as applied to buried mine detection. While the majority of our effort has been concentrated on the buried mine problem, LLNL has worked with the U.S.M.C. on surface mine problems as well, providing data and analysis to support the COBRA (Coastal Battlefield Reconnaissance and Analysis) program. The original aim of the experimental aspect of the program was the utilization of multiband infrared approaches for the detection of buried mines. Later the work was extended to a multisensor investigation, including sensors other than infrared imagers. After an early series of measurements, it was determined that further progress would require a larger test facility in a natural environment, so the Buried Object Test Facility (BOTF) was constructed at the Nevada Test Site. After extensive testing, with sensors spanning the electromagnetic spectrum from the near ultraviolet to radio frequencies, possible paths for improvement were: improved spatial resolution providing better ground texture discrimination; analysis which involves more complicated spatial queueing and filtering; additional IR bands using imaging spectroscopy; the use of additional sensors other than IR and the use of data fusion techniques with multi-sensor data; and utilizing time dependent observables like temperature.« less

  13. A Testing Platform for Validation of Overhead Conductor Aging Models and Understanding Thermal Limits

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Irminger, Philip; Starke, Michael R; Dimitrovski, Aleksandar D

    2014-01-01

    Power system equipment manufacturers and researchers continue to experiment with novel overhead electric conductor designs that support better conductor performance and address congestion issues. To address the technology gap in testing these novel designs, Oak Ridge National Laboratory constructed the Powerline Conductor Accelerated Testing (PCAT) facility to evaluate the performance of novel overhead conductors in an accelerated fashion in a field environment. Additionally, PCAT has the capability to test advanced sensors and measurement methods for accessing overhead conductor performance and condition. Equipped with extensive measurement and monitoring devices, PCAT provides a platform to improve/validate conductor computer models and assess themore » performance of novel conductors. The PCAT facility and its testing capabilities are described in this paper.« less

  14. Hydrogen Infrastructure Testing and Research Facility Video (Text Version)

    Science.gov Websites

    grid integration, continuous code improvement, fuel cell vehicle operation, and renewable hydrogen stations. NRELs research on hydrogen safety provides guidance for safe operation, handling, and use of standards and testing fuel cell and hydrogen components for operation and safety. Building on NRELs Wind-to

  15. Registered nurses' medication management of the elderly in aged care facilities.

    PubMed

    Lim, L M; Chiu, L H; Dohrmann, J; Tan, K-L

    2010-03-01

    Data on adverse drug reactions (ADRs) showed a rising trend in the elderly over 65 years using multiple medications. To identify registered nurses' (RNs) knowledge of medication management and ADRs in the elderly in aged care facilities; evaluate an education programme to increase pharmacology knowledge and prevent ADRs in the elderly; and develop a learning programme with a view to extending provision, if successful. This exploratory study used a non-randomized pre- and post-test one group quasi-experimental design without comparators. It comprised a 23-item knowledge-based test questionnaire, one-hour teaching session and a self-directed learning package. The volunteer sample was RNs from residential aged care facilities, involved in medication management. Participants sat a pre-test immediately before the education, and post-test 4 weeks later (same questionnaire). Participants' perceptions obtained. Pre-test sample n = 58, post-test n = 40, attrition rate of 31%. Using Microsoft Excel 2000, descriptive statistical data analysis of overall pre- and post-test incorrect responses showed: pre-test proportion of incorrect responses = 0.40; post-test proportion of incorrect responses = 0.27; Z-test comparing pre- and post-tests scores of incorrect responses = 6.55 and one-sided P-value = 2.8E-11 (P < 0.001). Pre-test showed knowledge deficits in medication management and ADRs in the elderly; post-test showed statistically significant improvement in RNs' knowledge. It highlighted a need for continuing professional education. Further studies are required on a larger sample of RNs in other aged care facilities, and on the clinical impact of education by investigating nursing practice and elderly residents' outcomes.

  16. Effects of the EQUIP quasi-experimental study testing a collaborative quality improvement approach for maternal and newborn health care in Tanzania and Uganda.

    PubMed

    Waiswa, P; Manzi, F; Mbaruku, G; Rowe, A K; Marx, M; Tomson, G; Marchant, T; Willey, B A; Schellenberg, J; Peterson, S; Hanson, C

    2017-07-18

    Quality improvement is a recommended strategy to improve implementation levels for evidence-based essential interventions, but experience of and evidence for its effects in low-resource settings are limited. We hypothesised that a systemic and collaborative quality improvement approach covering district, facility and community levels, supported by report cards generated through continuous household and health facility surveys, could improve the implementation levels and have a measurable population-level impact on coverage and quality of essential services. Collaborative quality improvement teams tested self-identified strategies (change ideas) to support the implementation of essential maternal and newborn interventions recommended by the World Health Organization. In Tanzania and Uganda, we used a plausibility design to compare the changes over time in one intervention district with those in a comparison district in each country. Evaluation included indicators of process, coverage and implementation practice analysed with a difference-of-differences and a time-series approach, using data from independent continuous household and health facility surveys from 2011 to 2014. Primary outcomes for both countries were birth in health facilities, breastfeeding within 1 h after birth, oxytocin administration after birth and knowledge of danger signs for mothers and babies. Interpretation of the results considered contextual factors. The intervention was associated with improvements on one of four primary outcomes. We observed a 26-percentage-point increase (95% CI 25-28%) in the proportion of live births where mothers received uterotonics within 1 min after birth in the intervention compared to the comparison district in Tanzania and an 8-percentage-point increase (95% CI 6-9%) in Uganda. The other primary indicators showed no evidence of improvement. In Tanzania, we saw positive changes for two other outcomes reflecting locally identified improvement topics. The intervention was associated with an increase in preparation of clean birth kits for home deliveries (31 percentage points, 95% CI 2-60%) and an increase in health facility supervision by district staff (14 percentage points, 95% CI 0-28%). The systemic quality improvement approach was associated with improvements of only one of four primary outcomes, as well as two Tanzania-specific secondary outcomes. Reasons for the lack of effects included limited implementation strength as well a relatively short follow-up period in combination with a 1-year recall period for population-based estimates and a limited power of the study to detect changes smaller than 10 percentage points. Pan African Clinical Trials Registry: PACTR201311000681314.

  17. SuperCDMS Underground Detector Fabrication Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Platt, M.; Mahapatra, R.; Bunker, Raymond A.

    The SuperCDMS SNOLAB dark matter experiment processes Ge and Si crystals into fully tested phonon and ionization detectors at surface fabrication and test facilities. If not mitigated, it is anticipated that trace-level production of radioisotopes in the crystals due to exposure to cosmic rays at (or above) sea level will result in the dominant source of background events in future dark matter searches using the current SuperCDMS detector technology. Fabrication and testing of detectors in underground facilities shielded from cosmic radiation is one way to directly reduce production of trace levels of radioisotopes, thereby improving experimental sensitivity for the discoverymore » of dark matter beyond the level of the current experiment. In this report, we investigate the cost and feasibility to establish a complete detector fabrication processing chain in an underground location to mitigate cosmogenic activation of the Ge and Si detector substrates. For a specific and concrete evaluation, we explore options for such a facility located at SNOLAB, an underground laboratory in Sudbury, Canada hosting the current and future experimental phases of SuperCDMS.« less

  18. Long Duration Hot Hydrogen Exposure of Nuclear Thermal Rocket Materials

    NASA Technical Reports Server (NTRS)

    Litchford, Ron J.; Foote, John P.; Hickman, Robert; Dobson, Chris; Clifton, Scooter

    2007-01-01

    An arc-heater driven hyper-thermal convective environments simulator was recently developed and commissioned for long duration hot hydrogen exposure of nuclear thermal rocket materials. This newly established non-nuclear testing capability uses a high-power, multi-gas, wall-stabilized constricted arc-heater to .produce high-temperature pressurized hydrogen flows representative of nuclear reactor core environments, excepting radiation effects, and is intended to serve as a low cost test facility for the purpose of investigating and characterizing candidate fuel/structural materials and improving associated processing/fabrication techniques. Design and engineering development efforts are fully summarized, and facility operating characteristics are reported as determined from a series of baseline performance mapping runs and long duration capability demonstration tests.

  19. Gain Evaluation of Micro-Channel-Plate Photomultipliers in the Upgraded High-B Test Facility at Jefferson Lab

    NASA Astrophysics Data System (ADS)

    Barber, Corinne; DIRC at EIC Collaboration

    2015-10-01

    The High-B test facility at Thomas Jefferson National Accelerator Facility allows researchers to evaluate the gain of compact photon sensors, such as Micro-Channel-Plate Photomultipliers (MCP-PMTs), in magnetic fields up to 5 T. These ongoing studies support the development of a Detector of Internally Reflected Cherenkov light (DIRC) to be used in an Electron Ion Collider (EIC). Here, we present our summer 2015 activities to upgrade and improve the facility, and we show results for MCP-PMT gain changes in high B-fields. To monitor the light stability delivered to the MCP-PMTs being tested, we implemented a Silicon Photomultiplier (SiPM) in the setup and calibrated the ADC reading this sensor. A 405-nm Light-Emitting Diode (LED) housed in an optical tube compatible with neutral density filters was also installed. The filters provide an alternative way of reducing the light output of the LED to operate the MCP-PMTs in a single-photon mode. We calibrated a set of filters by means of a photodiode and measured the photon flux at multiple positions relative to the LED. This information helped us to design 3D-printed holders unique to each MCP-PMT so that the photocathode receives the greatest amount of light. The improvements to the setup allow for more precise PMT gain evaluation. This team includes 7 collaborators/co-authors besides myself: Yordanka Ilieva, Kijun Park, Greg Kalicy, Carl Zorn, Pawel Nadel-Turonski, Tongtong Cao, and Lee.

  20. Initial research program for the National Transonic Facility

    NASA Technical Reports Server (NTRS)

    Gloss, B. B.

    1984-01-01

    The construction and checkout of the National Transonic Facility (NTF) have been completed, and detailed calibration is now in progress. The initial NTF research program covers a wide range of study areas falling into three major elements: (1) the assessment of Reynolds number sensitivities for a broad range of configurations and flow phenomena; (2) validation of the ability of NTF to simulate full-scale aerodynamics; and (3) the development of test techniques for improved test simulations in existing wind tunnels. This paper, therefore, is a status report on these various elements of the initial NTF research program.

  1. NASA tire/runway friction projects

    NASA Technical Reports Server (NTRS)

    Yager, Thomas J.

    1995-01-01

    The paper reviews several aspects of NASA Langley Research Center's tire/runway friction evaluations directed towards improving the safety and economy of aircraft ground operations. The facilities and test equipment used in implementing different aircraft tire friction studies and other related aircraft ground performance investigations are described together with recent workshop activities at NASA Wallops Flight Facility. An overview of the pending Joint NASA/Transport Canada/FM Winter Runway Friction Program is given. Other NASA ongoing studies and on-site field tests are discussed including tire wear performance and new surface treatments. The paper concludes with a description of future research plans.

  2. 26th Space Simulation Conference Proceedings. Environmental Testing: The Path Forward

    NASA Technical Reports Server (NTRS)

    Packard, Edward A.

    2010-01-01

    Topics covered include: A Multifunctional Space Environment Simulation Facility for Accelerated Spacecraft Materials Testing; Exposure of Spacecraft Surface Coatings in a Simulated GEO Radiation Environment; Gravity-Offloading System for Large-Displacement Ground Testing of Spacecraft Mechanisms; Microscopic Shutters Controlled by cRIO in Sounding Rocket; Application of a Physics-Based Stabilization Criterion to Flight System Thermal Testing; Upgrade of a Thermal Vacuum Chamber for 20 Kelvin Operations; A New Approach to Improve the Uniformity of Solar Simulator; A Perfect Space Simulation Storm; A Planetary Environmental Simulator/Test Facility; Collimation Mirror Segment Refurbishment inside ESA s Large Space; Space Simulation of the CBERS 3 and 4 Satellite Thermal Model in the New Brazilian 6x8m Thermal Vacuum Chamber; The Certification of Environmental Chambers for Testing Flight Hardware; Space Systems Environmental Test Facility Database (SSETFD), Website Development Status; Wallops Flight Facility: Current and Future Test Capabilities for Suborbital and Orbital Projects; Force Limited Vibration Testing of JWST NIRSpec Instrument Using Strain Gages; Investigation of Acoustic Field Uniformity in Direct Field Acoustic Testing; Recent Developments in Direct Field Acoustic Testing; Assembly, Integration and Test Centre in Malaysia: Integration between Building Construction Works and Equipment Installation; Complex Ground Support Equipment for Satellite Thermal Vacuum Test; Effect of Charging Electron Exposure on 1064nm Transmission through Bare Sapphire Optics and SiO2 over HfO2 AR-Coated Sapphire Optics; Environmental Testing Activities and Capabilities for Turkish Space Industry; Integrated Circuit Reliability Simulation in Space Environments; Micrometeoroid Impacts and Optical Scatter in Space Environment; Overcoming Unintended Consequences of Ambient Pressure Thermal Cycling Environmental Tests; Performance and Functionality Improvements to Next Generation Thermal Vacuum Control System; Robotic Lunar Lander Development Project: Three-Dimensional Dynamic Stability Testing and Analysis; Thermal Physical Properties of Thermal Coatings for Spacecraft in Wide Range of Environmental Conditions: Experimental and Theoretical Study; Molecular Contamination Generated in Thermal Vacuum Chambers; Preventing Cross Contamination of Hardware in Thermal Vacuum Chambers; Towards Validation of Particulate Transport Code; Updated Trends in Materials' Outgassing Technology; Electrical Power and Data Acquisition Setup for the CBER 3 and 4 Satellite TBT; Method of Obtaining High Resolution Intrinsic Wire Boom Damping Parameters for Multi-Body Dynamics Simulations; and Thermal Vacuum Testing with Scalable Software Developed In-House.

  3. Main outcomes of an RCT to pilot test reporting and feedback to foster research integrity climates in the VA.

    PubMed

    Martinson, Brian C; Mohr, David C; Charns, Martin P; Nelson, David; Hagel-Campbell, Emily; Bangerter, Ann; Bloomfield, Hanna E; Owen, Richard; Thrush, Carol R

    2017-01-01

    Assessing the integrity of research climates and sharing such information with research leaders may support research best practices. We report here results of a pilot trial testing the effectiveness of a reporting and feedback intervention using the Survey of Organizational Research Climate (SOuRCe). We randomized 41 Veterans Health Administration (VA) facilities to a phone-based intervention designed to help research leaders understand their survey results (enhanced arm) or to an intervention in which results were simply distributed to research leaders (basic arm). Primary outcomes were (1) whether leaders took action, (2) whether actions taken were consistent with the feedback received, and (3) whether responses differed by receptivity to quality improvement input. Research leaders from 25 of 42 (59%) VA facilities consented to participate in the study intervention and follow-up, of which 14 were at facilities randomized to the enhanced arm. We completed follow-up interviews with 21 of the 25 leaders (88%), 12 from enhanced arm facilities. While not statistically significant, the proportion of leaders reporting taking some action in response to the feedback was twice as high in the enhanced arm than in the basic arm (67% vs. 33%, p = .20). While also not statistically significant, a higher proportion of actions taken among facilities in the enhanced arm were responsive to the survey results than in the basic arm (42% vs. 22%, p = .64). Enhanced feedback of survey results appears to be a promising intervention that may increase the likelihood of responsive action to improve organizational climates. Due to the small sample size of this pilot study, even large percentage-point differences between study arms are not statistically distinguishable. This hypothesis should be tested in a larger trial.

  4. Hyperthermal Environments Simulator for Nuclear Rocket Engine Development

    NASA Technical Reports Server (NTRS)

    Litchford, Ron J.; Foote, John P.; Clifton, W. B.; Hickman, Robert R.; Wang, Ten-See; Dobson, Christopher C.

    2011-01-01

    An arc-heater driven hyperthermal convective environments simulator was recently developed and commissioned for long duration hot hydrogen exposure of nuclear thermal rocket materials. This newly established non-nuclear testing capability uses a high-power, multi-gas, wall-stabilized constricted arc-heater to produce hightemperature pressurized hydrogen flows representative of nuclear reactor core environments, excepting radiation effects, and is intended to serve as a low-cost facility for supporting non-nuclear developmental testing of hightemperature fissile fuels and structural materials. The resulting reactor environments simulator represents a valuable addition to the available inventory of non-nuclear test facilities and is uniquely capable of investigating and characterizing candidate fuel/structural materials, improving associated processing/fabrication techniques, and simulating reactor thermal hydraulics. This paper summarizes facility design and engineering development efforts and reports baseline operational characteristics as determined from a series of performance mapping and long duration capability demonstration tests. Potential follow-on developmental strategies are also suggested in view of the technical and policy challenges ahead. Keywords: Nuclear Rocket Engine, Reactor Environments, Non-Nuclear Testing, Fissile Fuel Development.

  5. Safety Evaluation Report: Development of Improved Composite Pressure Vessels for Hydrogen Storage, Lincoln Composites, Lincoln, NE, May 25, 2010

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fort, III, William C.; Kallman, Richard A.; Maes, Miguel

    2010-12-22

    Lincoln Composites operates a facility for designing, testing, and manufacturing composite pressure vessels. Lincoln Composites also has a U.S. Department of Energy (DOE)-funded project to develop composite tanks for high-pressure hydrogen storage. The initial stage of this project involves testing the permeation of high-pressure hydrogen through polymer liners. The company recently moved and is constructing a dedicated research/testing laboratory at their new location. In the meantime, permeation tests are being performed in a corner of a large manufacturing facility. The safety review team visited the Lincoln Composites site on May 25, 2010. The project team presented an overview of themore » company and project and took the safety review team on a tour of the facility. The safety review team saw the entire process of winding a carbon fiber/resin tank on a liner, installing the boss and valves, and curing and painting the tank. The review team also saw the new laboratory that is being built for the DOE project and the temporary arrangement for the hydrogen permeation tests.« less

  6. A macro-ergonomic work system analysis of the diagnostic testing process in an outpatient health care facility for process improvement and patient safety.

    PubMed

    Hallock, M L; Alper, S J; Karsh, B

    The diagnosis of illness is important for quality patient care and patient safety and is greatly aided by diagnostic testing. For diagnostic tests, such as pathology and radiology, to positively impact patient care, the tests must be processed and the physician and patient must be notified of the results in a timely fashion. There are many steps in the diagnostic testing process, from ordering to result dissemination, where the process can break down and therefore delay patient care and reduce patient safety. This study was carried out to examine the diagnostic testing process (i.e. from ordering to result notification) and used a macro-ergonomic work system analysis to uncover system design flaws that contributed to delayed physician and patient notification of results. The study was carried out in a large urban outpatient health-care facility made up of 30 outpatient clinics. Results indicated a number of variances that contributed to delays, the majority of which occurred across the boundaries of different systems and were related to poor or absent feedback structures. Recommendations for improvements are discussed.

  7. Towards elimination of mother-to-child transmission of HIV: performance of different models of care for initiating lifelong antiretroviral therapy for pregnant women in Malawi (Option B+).

    PubMed

    van Lettow, Monique; Bedell, Richard; Mayuni, Isabell; Mateyu, Gabriel; Landes, Megan; Chan, Adrienne K; van Schoor, Vanessa; Beyene, Teferi; Harries, Anthony D; Chu, Stephen; Mganga, Andrew; van Oosterhout, Joep J

    2014-01-01

    Malawi introduced a new strategy to improve the effectiveness of prevention of mother-to-child HIV transmission (PMTCT), the Option B+ strategy. We aimed to (i) describe how Option B+ is provided in health facilities in the South East Zone in Malawi, identifying the diverse approaches to service organization (the "model of care") and (ii) explore associations between the "model of care" and health facility-level uptake and retention rates for pregnant women identified as HIV-positive at antenatal (ANC) clinics. A health facility survey was conducted in all facilities providing PMTCT/antiretroviral therapy (ART) services in six of Malawi's 28 districts to describe and compare Option B+ service delivery models. Associations of identified models with program performance were explored using facility cohort reports. Among 141 health facilities, four "models of care" were identified: A) facilities where newly identified HIV-positive women are initiated and followed on ART at the ANC clinic until delivery; B) facilities where newly identified HIV-positive women receive only the first dose of ART at the ANC clinic, and are referred to the ART clinic for follow-up; C) facilities where newly identified HIV-positive women are referred from ANC to the ART clinic for initiation and follow-up of ART; and D) facilities serving as ART referral sites (not providing ANC). The proportion of women tested for HIV during ANC was highest in facilities applying Model A and lowest in facilities applying Model B. The highest retention rates were reported in Model C and D facilities and lowest in Model B facilities. In multivariable analyses, health facility factors independently associated with uptake of HIV testing and counselling (HTC) in ANC were number of women per HTC counsellor, HIV test kit availability, and the "model of care" applied; factors independently associated with ART retention were district location, patient volume and the "model of care" applied. A large variety exists in the way health facilities have integrated PMTCT Option B+ care into routine service delivery. This study showed that the "model of care" chosen is associated with uptake of HIV testing in ANC and retention in care on ART. Further patient-level research is needed to guide policy recommendations.

  8. "Mobile technology to improve heart failure outcomes: A proof of concept paper".

    PubMed

    Athilingam, Ponrathi; Jenkins, Bradlee A; Zumpano, Heather; Labrador, Miguel A

    2018-02-01

    Heart failure (HF) causes significant symptom burden and human suffering with considerable economic burden due to hospital readmissions. Targeted interventions to encourage and support self-management behavior is warranted. To test the proof of concept of a mobile application (HeartMapp) in improving self-care management of patients with heart failure. An exploratory inquiry used a field study strategy with purposeful sampling and constant comparative analysis to test the proof of concept of HeartMapp using The Business Model Canvas framework. A total of 125 individuals, who were identified as potential candidates to use the HeartMapp completed the interview over a seven-week period in 2016. Constant comparative analysis indicated themes that Skilled Nursing Facilities had increased readmissions. Participants from Skilled Nursing Facilities reported concern on lack of staffing, star rating, and malpractice claims. Two types of patients were identified as early adapters of technology and those in denial. Health care facilities reported challenges on transitional care, nurses struggle with engagement of patients on self-care management. To avoid readmission penalty, hospitals task home care agencies to keep the patients home for 30-days. While home care agencies rely on remote telemonitoring reported that current telemonitoring devices are costly to maintain, thus exploring novel technology. The Business Model Canvas provided directions for future testing of HeartMapp for its usability as an adjunct device in home health setting to improve self-management and enhance communication with providers, and ultimately reduce readmissions. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Research and test facilities for development of technologies and experiments with commercial applications

    NASA Technical Reports Server (NTRS)

    1989-01-01

    One of NASA'S agency-wide goals is the commercial development of space. To further this goal NASA is implementing a policy whereby U.S. firms are encouraged to utilize NASA facilities to develop and test concepts having commercial potential. Goddard, in keeping with this policy, will make the facilities and capabilities described in this document available to private entities at a reduced cost and on a noninterference basis with internal NASA programs. Some of these facilities include: (1) the Vibration Test Facility; (2) the Battery Test Facility; (3) the Large Area Pulsed Solar Simulator Facility; (4) the High Voltage Testing Facility; (5) the Magnetic Field Component Test Facility; (6) the Spacecraft Magnetic Test Facility; (7) the High Capacity Centrifuge Facility; (8) the Acoustic Test Facility; (9) the Electromagnetic Interference Test Facility; (10) the Space Simulation Test Facility; (11) the Static/Dynamic Balance Facility; (12) the High Speed Centrifuge Facility; (13) the Optical Thin Film Deposition Facility; (14) the Gold Plating Facility; (15) the Paint Formulation and Application Laboratory; (16) the Propulsion Research Laboratory; (17) the Wallops Range Facility; (18) the Optical Instrument Assembly and Test Facility; (19) the Massively Parallel Processor Facility; (20) the X-Ray Diffraction and Scanning Auger Microscopy/Spectroscopy Laboratory; (21) the Parts Analysis Laboratory; (22) the Radiation Test Facility; (23) the Ainsworth Vacuum Balance Facility; (24) the Metallography Laboratory; (25) the Scanning Electron Microscope Laboratory; (26) the Organic Analysis Laboratory; (27) the Outgassing Test Facility; and (28) the Fatigue, Fracture Mechanics and Mechanical Testing Laboratory.

  10. Comparison of the diagnostic accuracy of a rapid immunochromatographic test and the rapid plasma reagin test for antenatal syphilis screening in Mozambique.

    PubMed Central

    Montoya, Pablo J.; Lukehart, Sheila A.; Brentlinger, Paula E.; Blanco, Ana J.; Floriano, Florencia; Sairosse, Josefa; Gloyd, Stephen

    2006-01-01

    OBJECTIVE: Programmes to control syphilis in developing countries are hampered by a lack of laboratory services, delayed diagnosis, and doubts about current screening methods. We aimed to compare the diagnostic accuracy of an immunochromatographic strip (ICS) test and the rapid plasma reagin (RPR) test with the combined gold standard (RPR, Treponema pallidum haemagglutination assay and direct immunofluorescence stain done at a reference laboratory) for the detection of syphilis in pregnancy. METHODS: We included test results from 4789 women attending their first antenatal visit at one of six health facilities in Sofala Province, central Mozambique. We compared diagnostic accuracy (sensitivity, specificity, and positive and negative predictive values) of ICS and RPR done at the health facilities and ICS performed at the reference laboratory. We also made subgroup comparisons by human immunodeficiency virus (HIV) and malaria status. FINDINGS: For active syphilis, the sensitivity of the ICS was 95.3% at the reference laboratory, and 84.1% at the health facility. The sensitivity of the RPR at the health facility was 70.7%. Specificity and positive and negative predictive values showed a similar pattern. The ICS outperformed RPR in all comparisons (P<0.001). CONCLUSION: The diagnostic accuracy of the ICS compared favourably with that of the gold standard. The use of the ICS in Mozambique and similar settings may improve the diagnosis of syphilis in health facilities, both with and without laboratories. PMID:16501726

  11. Modernization and Activation of the NASA Ames 11- by 11-Foot Transonic Wind Tunnel

    NASA Technical Reports Server (NTRS)

    Kmak, Frank J.

    2000-01-01

    The Unitary Plan Wind Tunnel (UPWT) was modernized to improve performance, capability, productivity, and reliability. Automation systems were installed in all three UPWT tunnel legs and the Auxiliaries facility. Major improvements were made to the four control rooms, model support systems, main drive motors, and main drive speed control. Pressure vessel repairs and refurbishment to the electrical distribution system were also completed. Significant changes were made to improve test section flow quality in the 11-by 11-Foot Transonic leg. After the completion of the construction phase of the project, acceptance and checkout testing was performed to demonstrate the capabilities of the modernized facility. A pneumatic test of the tunnel circuit was performed to verify the structural integrity of the pressure vessel before wind-on operations. Test section turbulence, flow angularity, and acoustic parameters were measured throughout the tunnel envelope to determine the effects of the tunnel flow quality improvements. The new control system processes were thoroughly checked during wind-off and wind-on operations. Manual subsystem modes and automated supervisory modes of tunnel operation were validated. The aerodynamic and structural performance of both the new composite compressor rotor blades and the old aluminum rotor blades was measured. The entire subsonic and supersonic envelope of the 11-by 11-Foot Transonic leg was defined up to the maximum total pressure.

  12. Mach Stability Improvements Using an Existing Second Throat Capability at the National Transonic Facility

    NASA Technical Reports Server (NTRS)

    Chan, David T.; Balakrishna, Sundareswara; Walker, Eric L.; Goodliff, Scott L.

    2015-01-01

    Recent data quality improvements at the National Transonic Facility have an intended goal of reducing the Mach number variation in a data point to within plus or minus 0.0005, with the ultimate goal of reducing the data repeatability of the drag coefficient for full-span subsonic transport models at transonic speeds to within half a drag count. This paper will discuss the Mach stability improvements achieved through the use of an existing second throat capability at the NTF to create a minimum area at the end of the test section. These improvements were demonstrated using both the NASA Common Research Model and the NTF Pathfinder-I model in recent experiments. Sonic conditions at the throat were verified using sidewall static pressure data. The Mach variation levels from both experiments in the baseline tunnel configuration and the choked tunnel configuration will be presented and the correlation between Mach number and drag will also be examined. Finally, a brief discussion is given on the consequences of using the second throat in its location at the end of the test section.

  13. Mach Stability Improvements Using an Existing Second Throat Capability at the National Transonic Facility

    NASA Technical Reports Server (NTRS)

    Chan, David T.

    2015-01-01

    Recent data quality improvements at the National Transonic Facility (NTF) have an intended goal of reducing the Mach number variation in a data point to within unit vector A plus or minus 0.0005, with the ultimate goal of reducing the data repeatability of the drag coefficient for full-span subsonic transport models at transonic speeds to within half of a drag count. This paper will discuss the Mach stability improvements achieved through the use of an existing second throat capability at the NTF to create a minimum area at the end of the test section. These improvements were demonstrated using both the NASA Common Research Model and the NTF Pathfinder-I model in recent experiments. Sonic conditions at the throat were verified using sidewall static pressure data. The Mach variation levels from both experiments in the baseline tunnel configuration and the choked tunnel configuration will be presented. Finally, a brief discussion is given on the consequences of using the second throat in its location at the end of the test section.

  14. Comparison of Perceived and Technical Healthcare Quality in Primary Health Facilities: Implications for a Sustainable National Health Insurance Scheme in Ghana

    PubMed Central

    Alhassan, Robert Kaba; Duku, Stephen Opoku; Janssens, Wendy; Nketiah-Amponsah, Edward; Spieker, Nicole; van Ostenberg, Paul; Arhinful, Daniel Kojo; Pradhan, Menno; Rinke de Wit, Tobias F.

    2015-01-01

    Background Quality care in health facilities is critical for a sustainable health insurance system because of its influence on clients’ decisions to participate in health insurance and utilize health services. Exploration of the different dimensions of healthcare quality and their associations will help determine more effective quality improvement interventions and health insurance sustainability strategies, especially in resource constrained countries in Africa where universal access to good quality care remains a challenge. Purpose To examine the differences in perceptions of clients and health staff on quality healthcare and determine if these perceptions are associated with technical quality proxies in health facilities. Implications of the findings for a sustainable National Health Insurance Scheme (NHIS) in Ghana are also discussed. Methods This is a cross-sectional study in two southern regions in Ghana involving 64 primary health facilities: 1,903 households and 324 health staff. Data collection lasted from March to June, 2012. A Wilcoxon-Mann-Whitney test was performed to determine differences in client and health staff perceptions of quality healthcare. Spearman’s rank correlation test was used to ascertain associations between perceived and technical quality care proxies in health facilities, and ordered logistic regression employed to predict the determinants of client and staff-perceived quality healthcare. Results Negative association was found between technical quality and client-perceived quality care (coef. = -0.0991, p<0.0001). Significant staff-client perception differences were found in all healthcare quality proxies, suggesting some level of unbalanced commitment to quality improvement and potential information asymmetry between clients and service providers. Overall, the findings suggest that increased efforts towards technical quality care alone will not necessarily translate into better client-perceived quality care and willingness to utilize health services in NHIS-accredited health facilities. Conclusion There is the need to intensify client education and balanced commitment to technical and perceived quality improvement efforts. This will help enhance client confidence in Ghana’s healthcare system, stimulate active participation in the national health insurance, increase healthcare utilization and ultimately improve public health outcomes. PMID:26465935

  15. Comparison of Perceived and Technical Healthcare Quality in Primary Health Facilities: Implications for a Sustainable National Health Insurance Scheme in Ghana.

    PubMed

    Alhassan, Robert Kaba; Duku, Stephen Opoku; Janssens, Wendy; Nketiah-Amponsah, Edward; Spieker, Nicole; van Ostenberg, Paul; Arhinful, Daniel Kojo; Pradhan, Menno; Rinke de Wit, Tobias F

    2015-01-01

    Quality care in health facilities is critical for a sustainable health insurance system because of its influence on clients' decisions to participate in health insurance and utilize health services. Exploration of the different dimensions of healthcare quality and their associations will help determine more effective quality improvement interventions and health insurance sustainability strategies, especially in resource constrained countries in Africa where universal access to good quality care remains a challenge. To examine the differences in perceptions of clients and health staff on quality healthcare and determine if these perceptions are associated with technical quality proxies in health facilities. Implications of the findings for a sustainable National Health Insurance Scheme (NHIS) in Ghana are also discussed. This is a cross-sectional study in two southern regions in Ghana involving 64 primary health facilities: 1,903 households and 324 health staff. Data collection lasted from March to June, 2012. A Wilcoxon-Mann-Whitney test was performed to determine differences in client and health staff perceptions of quality healthcare. Spearman's rank correlation test was used to ascertain associations between perceived and technical quality care proxies in health facilities, and ordered logistic regression employed to predict the determinants of client and staff-perceived quality healthcare. Negative association was found between technical quality and client-perceived quality care (coef. = -0.0991, p<0.0001). Significant staff-client perception differences were found in all healthcare quality proxies, suggesting some level of unbalanced commitment to quality improvement and potential information asymmetry between clients and service providers. Overall, the findings suggest that increased efforts towards technical quality care alone will not necessarily translate into better client-perceived quality care and willingness to utilize health services in NHIS-accredited health facilities. There is the need to intensify client education and balanced commitment to technical and perceived quality improvement efforts. This will help enhance client confidence in Ghana's healthcare system, stimulate active participation in the national health insurance, increase healthcare utilization and ultimately improve public health outcomes.

  16. Drive System Enhancement in the NASA Lewis Research Center Supersonic Wind Tunnels

    NASA Technical Reports Server (NTRS)

    Becks, Edward A.

    1998-01-01

    An overview of NASA Lewis' Aeropropulsion Wind Tunnel Productivity Improvements was presented at the 19th AIAA Advanced Measurement & Ground Testing Technology Conference. Since that time Lewis has implemented subsonic operation in their 10- by 10-Foot Supersonic Wind Tunnel as had been proven viable in the 8- by 6 and 9- by 15-Foot Wind Tunnel Complex and discussed at the aforementioned conference. In addition, two more years of data have been gathered to help quantify the true productivity increases in these facilities attributable to the drive system and operational improvements. This paper was invited for presentation at the 20th Advanced Measurement and Ground Testing Conference to discuss and quantify the productivity improvements in the 10- by 10 SWT since the implementation of less than full complement motor operation. An update on the increased productivity at the 8- by 6 and 9- by 15-Foot facility due to drive system enhancements will also be presented.

  17. Geodetic Imaging Lidar: Applications for high-accuracy, large area mapping with NASA's upcoming high-altitude waveform-based airborne laser altimetry Facility

    NASA Astrophysics Data System (ADS)

    Blair, J. B.; Rabine, D.; Hofton, M. A.; Citrin, E.; Luthcke, S. B.; Misakonis, A.; Wake, S.

    2015-12-01

    Full waveform laser altimetry has demonstrated its ability to capture highly-accurate surface topography and vertical structure (e.g. vegetation height and structure) even in the most challenging conditions. NASA's high-altitude airborne laser altimeter, LVIS (the Land Vegetation, and Ice Sensor) has produced high-accuracy surface maps over a wide variety of science targets for the last 2 decades. Recently NASA has funded the transition of LVIS into a full-time NASA airborne Facility instrument to increase the amount and quality of the data and to decrease the end-user costs, to expand the utilization and application of this unique sensor capability. Based heavily on the existing LVIS sensor design, the Facility LVIS instrument includes numerous improvements for reliability, resolution, real-time performance monitoring and science products, decreased operational costs, and improved data turnaround time and consistency. The development of this Facility instrument is proceeding well and it is scheduled to begin operations testing in mid-2016. A comprehensive description of the LVIS Facility capability will be presented along with several mission scenarios and science applications examples. The sensor improvements included increased spatial resolution (footprints as small as 5 m), increased range precision (sub-cm single shot range precision), expanded dynamic range, improved detector sensitivity, operational autonomy, real-time flight line tracking, and overall increased reliability and sensor calibration stability. The science customer mission planning and data product interface will be discussed. Science applications of the LVIS Facility include: cryosphere, territorial ecology carbon cycle, hydrology, solid earth and natural hazards, and biodiversity.

  18. A stochastic discrete optimization model for designing container terminal facilities

    NASA Astrophysics Data System (ADS)

    Zukhruf, Febri; Frazila, Russ Bona; Burhani, Jzolanda Tsavalista

    2017-11-01

    As uncertainty essentially affect the total transportation cost, it remains important in the container terminal that incorporates several modes and transshipments process. This paper then presents a stochastic discrete optimization model for designing the container terminal, which involves the decision of facilities improvement action. The container terminal operation model is constructed by accounting the variation of demand and facilities performance. In addition, for illustrating the conflicting issue that practically raises in the terminal operation, the model also takes into account the possible increment delay of facilities due to the increasing number of equipment, especially the container truck. Those variations expectantly reflect the uncertainty issue in the container terminal operation. A Monte Carlo simulation is invoked to propagate the variations by following the observed distribution. The problem is constructed within the framework of the combinatorial optimization problem for investigating the optimal decision of facilities improvement. A new variant of glow-worm swarm optimization (GSO) is thus proposed for solving the optimization, which is rarely explored in the transportation field. The model applicability is tested by considering the actual characteristics of the container terminal.

  19. Current Status of the Utilization of Powered Wheelchair in Preschool Children with Locomotive Disability in Japan

    PubMed Central

    UYAMA, Sachie; HANAKI, Keiichi

    2016-01-01

    [Purpose] This study aimed to elucidate the actual state of powered wheelchair (PWC) prescription for preschool children with disabilities in Japan, and also to determine the approximate number of preschool children with disabilities who would potentially benefit from PWC use. [Subjects and Methods] A total of 318 facilities providing rehabilitation for disabled children in Japan were enrolled in the study. A questionnaire about PWC use for preschoolers was mailed to the facilities. Each study items were analyzed employing the Fisher's exact test. [Results] Of the 318 facilities, consent to participate in this study was obtained from 108 (return rate: 34.0%). After PWC provision, many facilities reported improvement in quality of life indices for preschool children with disabilities. It was revealed that there were 6 preschool children from 2 to 6 years of age with disabilities who might acquire a means of independent locomotion through PWC provision and thereby experience improved quality of life. [Conclusion] There was no negative comment from the facilities studied about the prescription and provision of PWC for preschool children with disabilities. PMID:28289577

  20. Completeness of malaria indicator data reporting via the District Health Information Software 2 in Kenya, 2011-2015.

    PubMed

    Githinji, Sophie; Oyando, Robinson; Malinga, Josephine; Ejersa, Waqo; Soti, David; Rono, Josea; Snow, Robert W; Buff, Ann M; Noor, Abdisalan M

    2017-08-17

    Health facility-based data reported through routine health information systems form the primary data source for programmatic monitoring and evaluation in most developing countries. The adoption of District Health Information Software (DHIS2) has contributed to improved availability of routine health facility-based data in many low-income countries. An assessment of malaria indicators data reported by health facilities in Kenya during the first 5 years of implementation of DHIS2, from January 2011 to December 2015, was conducted. Data on 19 malaria indicators reported monthly by health facilities were extracted from the online Kenya DHIS2 database. Completeness of reporting was analysed for each of the 19 malaria indicators and expressed as the percentage of data values actually reported over the expected number; all health facilities were expected to report data for each indicator for all 12 months in a year. Malaria indicators data were analysed for 6235 public and 3143 private health facilities. Between 2011 and 2015, completeness of reporting in the public sector increased significantly for confirmed malaria cases across all age categories (26.5-41.9%, p < 0.0001, in children aged <5 years; 30.6-51.4%, p < 0.0001, in persons aged ≥5 years). Completeness of reporting of new antenatal care (ANC) clients increased from 53.7 to 70.5%, p < 0.0001). Completeness of reporting of intermittent preventive treatment in pregnancy (IPTp) decreased from 64.8 to 53.7%, p < 0.0001 for dose 1 and from 64.6 to 53.4%, p < 0.0001 for dose 2. Data on malaria tests performed and test results were not available in DHIS2 from 2011 to 2014. In 2015, sparse data on microscopy (11.5% for children aged <5 years; 11.8% for persons aged ≥5 years) and malaria rapid diagnostic tests (RDTs) (8.1% for all ages) were reported. In the private sector, completeness of reporting increased significantly for confirmed malaria cases across all age categories (16.7-23.1%, p < 0.0001, in children aged <5 years; 19.4-28.6%, p < 0.0001, in persons aged ≥5 years). Completeness of reporting also improved for new ANC clients (16.2-23.6%, p < 0.0001), and for IPTp doses 1 and 2 (16.6-20.2%, p < 0.0001 and 15.5-20.5%, p < 0.0001, respectively). In 2015, less than 3% of data values for malaria tests performed were reported in DHIS2 from the private sector. There have been sustained improvements in the completeness of data reported for most key malaria indicators since the adoption of DHIS2 in Kenya in 2011. However, major data gaps were identified for the malaria-test indicator and overall low reporting across all indicators from private health facilities. A package of proven DHIS2 implementation interventions and performance-based incentives should be considered to improve private-sector data reporting.

  1. Live births achieved via IVF are increased by improvements in air quality and laboratory environment.

    PubMed

    Heitmann, Ryan J; Hill, Micah J; James, Aidita N; Schimmel, Tim; Segars, James H; Csokmay, John M; Cohen, Jacques; Payson, Mark D

    2015-09-01

    Infertility is a common disease, which causes many couples to seek treatment with assisted reproduction techniques. Many factors contribute to successful assisted reproduction technique outcomes. One important factor is laboratory environment and air quality. Our facility had the unique opportunity to compare consecutively used, but separate assisted reproduction technique laboratories, as a result of a required move. Environmental conditions were improved by strategic engineering designs. All other aspects of the IVF laboratory, including equipment, physicians, embryologists, nursing staff and protocols, were kept constant between facilities. Air quality testing showed improved air quality at the new IVF site. Embryo implantation (32.4% versus 24.3%; P < 0.01) and live birth (39.3% versus 31.8%, P < 0.05) were significantly increased in the new facility compared with the old facility. More patients met clinical criteria and underwent mandatory single embryo transfer on day 5 leading to both a reduction in multiple gestation pregnancies and increased numbers of vitrified embryos per patient with supernumerary embryos available. Improvements in IVF laboratory conditions and air quality had profound positive effects on laboratory measures and patient outcomes. This study further strengthens the importance of the laboratory environment and air quality in the success of an IVF programme. Published by Elsevier Ltd.

  2. Process of constructing a lightweight x-ray flight mirror assembly

    NASA Astrophysics Data System (ADS)

    McClelland, Ryan S.; Biskach, Michael P.; Chan, Kai-Wing; Espina, Rebecca A.; Hohl, Bruce R.; Saha, Timo T.; Zhang, William W.

    2014-07-01

    Lightweight and high resolution optics are needed for future space-based x-ray telescopes to achieve advances in highenergy astrophysics. NASA's Next Generation X-ray Optics (NGXO) project has made significant progress towards building such optics, both in terms of maturing the technology for spaceflight readiness and improving the angular resolution. Technology Development Modules (TDMs) holding three pairs of mirrors have been regularly and repeatedly integrated and tested both for optical performance and mechanical strength. X-ray test results have been improved over the past year from 10.3 arc-seconds Half Power Diameter (HPD) to 8.3 arc-seconds HPD. A vibration test has been completed to NASA standard verification levels showing the optics can survive launch and pointing towards improvements in strengthening the modules through redundant bonds. A Finite Element Analysis (FEA) study was completed which shows the mirror distortion caused by bonding is insensitive to the number of bonds. Next generation TDMs, which will demonstrate a lightweight structure and mount additional pairs of mirrors, have been designed and fabricated. The light weight of the module structure is achieved through the use of E-60 Beryllium Oxide metal matrix composite material. As the angular resolution of the development modules has improved, gravity distortion during horizontal x-ray testing has become a limiting factor. To address this issue, a facility capable of testing in the vertical orientation has been designed and planned. Test boring at the construction site suggest standard caisson construction methods can be utilized to install a subterranean vertical vacuum pipe. This facility will also allow for the testing of kinematically mounted mirror segments, which greatly reduces the effect of bonding displacements. A development platform demonstrating the feasibility of kinematically mounting mirror segments has been designed, fabricated, and successfully tested.

  3. Changes in perceptions of quality of, and access to, services among clients of a fractional franchise network in Nepal.

    PubMed

    Agha, Sohail; Gage, Anastasia; Balal, Asma

    2007-05-01

    With declining levels of international donor funding for financing reproductive health programmes, developing country governments and international donors are looking towards private sector strategies to expand the supply of quality reproductive health services. One of the challenges of a health franchise is to improve the quality of services provided by independent private practitioners. Private providers are more likely to abide by the quality standards set by a franchiser if they see a financial benefit resulting from franchise participation. This study was conducted to measure whether (a) there were improvements in perceived quality of care and perceived access to health facilities once these facilities became part of a franchise and (b) improvements in perceived quality and perceived access were associated with increased client loyalty to franchised clinics. Franchisees were given basic reproductive health training for seven days and services marketing training for two days. Exit interviews were conducted with male and female clients at health facilities. A pre-test measurement was taken in April 2001, prior to the start of project activities. A post-test measurement was taken in February/March 2002, about 9 months after the pre-test. Multilevel regression analysis, which takes the hierarchical structure of the data into account, was used for the analysis. After taking provider-level variation into account and controlling for client characteristics, the analyses showed significant improvements in perceived quality of care and perceived access to services. Private provider participation in a franchise network helps improve client perceptions of quality of, and access to, services. Improvements in client perceptions of quality and access contribute to increased client loyalty to franchised clinics. Once increased client loyalty translates into higher client volumes, providers are likely to see the benefits of franchise participation. In turn, this should lead to increased provider willingness to remain part of the franchise and to abide by the standards of quality set by the franchiser.

  4. Development and Testing of a Sorbent-Based Atmosphere Revitalization System 2010/2011

    NASA Technical Reports Server (NTRS)

    Miller, Lee A.; Knox, James C.

    2012-01-01

    Spacecraft being developed for future exploration missions incorporate Environmental Control and Life Support Systems (ECLSS) that limit weight, power, and volume thus requiring systems with higher levels of efficiency while maintaining high dependability and robustness. For air revitalization, an approach that meets those goals utilizes a regenerative Vacuum-Swing Adsorption (VSA) system that removes 100% of the CO2 from the cabin atmosphere as well as 100% of the water. A Sorbent Based Atmosphere Revitalization (SBAR) system is a VSA system that utilizes standard commercial adsorbents that have been proven effective and safe in spacecraft including Skylab and the International Space Station. The SBAR system is the subject of a development, test, and evaluation program that is being conducted at NASA s Marshall Space Flight Center. While previous testing had validated that the technology is a viable option, potential improvements to system design and operation were identified. Modifications of the full-scale SBAR test articles and adsorption cycles have been implemented and have shown significant performance gains resulting in a decrease in the consumables required for a mission as well as improved mission safety. Previous testing had utilized single bed test articles, during this period the test facility was enhanced to allow testing on the full 2-bed SBAR system. The test facility simulates a spacecraft ECLSS and allows testing of the SBAR system over the full range of operational conditions using mission simulations that assess the real-time performance of the SBAR system during scenarios that include the metabolic transients associated with extravehicular activity. Although future manned missions are currently being redefined, the atmosphere revitalization requirements for the spacecraft are expected to be quite similar to the Orion and the Altair vehicles and the SBAR test program addressed validation to the defined mission requirements as well as operation in other potential vehicle architectures. The development program, including test articles, the test facility, and tests and results through early 2011 is discussed.

  5. Towards elimination of mother-to-child transmission of HIV: performance of different models of care for initiating lifelong antiretroviral therapy for pregnant women in Malawi (Option B+)

    PubMed Central

    van Lettow, Monique; Bedell, Richard; Mayuni, Isabell; Mateyu, Gabriel; Landes, Megan; Chan, Adrienne K; van Schoor, Vanessa; Beyene, Teferi; Harries, Anthony D; Chu, Stephen; Mganga, Andrew; van Oosterhout, Joep J

    2014-01-01

    Introduction Malawi introduced a new strategy to improve the effectiveness of prevention of mother-to-child HIV transmission (PMTCT), the Option B+ strategy. We aimed to (i) describe how Option B+ is provided in health facilities in the South East Zone in Malawi, identifying the diverse approaches to service organization (the “model of care”) and (ii) explore associations between the “model of care” and health facility–level uptake and retention rates for pregnant women identified as HIV-positive at antenatal (ANC) clinics. Methods A health facility survey was conducted in all facilities providing PMTCT/antiretroviral therapy (ART) services in six of Malawi's 28 districts to describe and compare Option B+ service delivery models. Associations of identified models with program performance were explored using facility cohort reports. Results Among 141 health facilities, four “models of care” were identified: A) facilities where newly identified HIV-positive women are initiated and followed on ART at the ANC clinic until delivery; B) facilities where newly identified HIV-positive women receive only the first dose of ART at the ANC clinic, and are referred to the ART clinic for follow-up; C) facilities where newly identified HIV-positive women are referred from ANC to the ART clinic for initiation and follow-up of ART; and D) facilities serving as ART referral sites (not providing ANC). The proportion of women tested for HIV during ANC was highest in facilities applying Model A and lowest in facilities applying Model B. The highest retention rates were reported in Model C and D facilities and lowest in Model B facilities. In multivariable analyses, health facility factors independently associated with uptake of HIV testing and counselling (HTC) in ANC were number of women per HTC counsellor, HIV test kit availability, and the “model of care” applied; factors independently associated with ART retention were district location, patient volume and the “model of care” applied. Conclusions A large variety exists in the way health facilities have integrated PMTCT Option B+ care into routine service delivery. This study showed that the “model of care” chosen is associated with uptake of HIV testing in ANC and retention in care on ART. Further patient-level research is needed to guide policy recommendations. PMID:25079437

  6. Availability and Quality of Family Planning Services in the Democratic Republic of the Congo: High Potential for Improvement

    PubMed Central

    Mpunga, Dieudonné; Lumbayi, JP; Dikamba, Nelly; Mwembo, Albert; Ali Mapatano, Mala; Wembodinga, Gilbert

    2017-01-01

    Objective: To determine the availability and quality of family planning services within health facilities throughout the Democratic Republic of the Congo (DRC). Methods: Data were collected for the cross-sectional study from April 2014 to June 2014 by the Ministry of Public Health. A total of 1,568 health facilities that reported data to the National Health Information System were selected by multistage random sampling in the 11 provinces of the DRC existing at that time. Data were collected through interviews, document review, and direct observation. Two dependent variables were measured: availability of family planning services (consisting of a room for services, staff assigned to family planning, and evidence of client use of family planning) and quality of family planning services (assessed as “high” if the facility had at least 1 trained staff member, family planning service delivery guidelines, at least 3 types of methods, and a sphygmomanometer, or “low” if the facility did not meet any of these 4 criteria). Pearson's chi-square test and odds ratios (ORs) were used to test for significant associations, using the alpha significance level of .05. Results: We successfully surveyed 1,555 facilities (99.2%) of those included in the sample. One in every 3 facilities (33%) offered family planning services as assessed by the index of availability, of which 20% met all 4 criteria for providing high-quality services. Availability was greatest at the highest level of the health system (hospitals) and decreased incrementally with each health system level, with disparities between provinces and urban and rural areas. Facilities in urban areas were more likely than in rural areas to meet the standard for high-quality services (P<.001). Public facilities were less likely than private facilities to have high-quality services (P=.02). Among all 1,555 facilities surveyed, 14% had at least 3 types of methods available at the time of the survey; the most widely available methods were male condoms, combined oral contraceptive pills, and progestin-only injectable contraceptives. Conclusion: Availability and quality of family planning services in health facilities in the DRC remain low, with inequitable distribution of services throughout the country. To improve access to and use of family planning, efforts should focus on improving availability and quality at lower health system levels and in rural areas where the majority of the population lives. PMID:28588047

  7. Hydrogen Infrastructure Testing and Research Facility | Hydrogen and Fuel

    Science.gov Websites

    stations, enabling NREL to validate current industry standards and methods for hydrogen fueling as well as the HITRF to: Develop, quantify performance of, and improve renewable hydrogen production methods

  8. Facility-based delivery in the context of Zimbabwe's HIV epidemic--missed opportunities for improving engagement with care: a community-based serosurvey.

    PubMed

    Buzdugan, Raluca; McCoy, Sandra I; Webb, Karen; Mushavi, Angela; Mahomva, Agnes; Padian, Nancy S; Cowan, Frances M

    2015-12-17

    In developing countries, facility-based delivery is recommended for maternal and neonatal health, and for prevention of mother-to-child HIV transmission (PMTCT). However, little is known about whether or not learning one's HIV status affects one's decision to deliver in a health facility. We examined this association in Zimbabwe. We analyzed data from a 2012 cross-sectional community-based serosurvey conducted to evaluate Zimbabwe's accelerated national PMTCT program. Eligible women (≥16 years old and mothers of infants born 9-18 months before the survey) were randomly sampled from the catchment areas of 157 health facilities in five of ten provinces. Participants were interviewed about where they delivered and provided blood samples for HIV testing. Overall 8796 (77 %) mothers reported facility-based delivery; uptake varied by community (30-100%). The likelihood of facility-based delivery was not associated with maternal HIV status. Women who self-reported being HIV-positive before delivery were as likely to deliver in a health facility as women who were HIV-negative, irrespective of when they learned their status - before (adjusted prevalence ratio (PRa) = 1.04, 95% confidence interval (CI) = 1.00-1.09) or during pregnancy (PRa = 1.05, 95% CI = 1.01-1.09). Mothers who had not accessed antenatal care or tested for HIV were most likely to deliver outside a health facility (69%). Overall, however 77% of home deliveries occurred among women who had accessed antenatal care and were HIV-tested. Uptake of facility-based delivery was similar among HIV-infected and HIV-uninfected mothers, which was somewhat unexpected given the substantial technical and financial investment aimed at retaining HIV-positive women in care in Zimbabwe.

  9. An evaluation of TRAC-PF1/MOD1 computer code performance during posttest simulations of Semiscale MOD-2C feedwater line break transients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hall, D.G.: Watkins, J.C.

    This report documents an evaluation of the TRAC-PF1/MOD1 reactor safety analysis computer code during computer simulations of feedwater line break transients. The experimental data base for the evaluation included the results of three bottom feedwater line break tests performed in the Semiscale Mod-2C test facility. The tests modeled 14.3% (S-FS-7), 50% (S-FS-11), and 100% (S-FS-6B) breaks. The test facility and the TRAC-PF1/MOD1 model used in the calculations are described. Evaluations of the accuracy of the calculations are presented in the form of comparisons of measured and calculated histories of selected parameters associated with the primary and secondary systems. In additionmore » to evaluating the accuracy of the code calculations, the computational performance of the code during the simulations was assessed. A conclusion was reached that the code is capable of making feedwater line break transient calculations efficiently, but there is room for significant improvements in the simulations that were performed. Recommendations are made for follow-on investigations to determine how to improve future feedwater line break calculations and for code improvements to make the code easier to use.« less

  10. Integration of Traditional Birth Attendants into Prevention of Mother-to-Child Transmission at Primary Health Facilities in Kaduna, North-West Nigeria.

    PubMed

    Nsirim, Reward O; Iyongo, Joseph A; Adekugbe, Olayinka; Ugochuku, Maureen

    2015-03-31

    One of the fundamental challenges to implementing successful prevention of mother-to-child transmission (PMTCT) programs in Nigeria is the uptake of PMTCT services at health facilities. Several issues usually discourage many pregnant women from receiving antenatal care services at designated health facilities within their communities. The CRS Nigeria PMTCT Project funded by the Global Fund in its Round 9 Phase 1 in Nigeria, sought to increase demand for HIV counseling and testing services for pregnant women at 25 supported primary health centers (PHCs) in Kaduna State, North-West Nigeria by integrating traditional birth attendants (TBAs) across the communities where the PHCs were located into the project. Community dialogues were held with the TBAs, community leaders and women groups. These dialogues focused on modes of mother to child transmission of HIV and the need for TBAs to refer their clients to PHCs for testing. Subsequently, data on number of pregnant women who were counseled, tested and received results was collected on a monthly basis from the 25 facilities using the national HIV/AIDS tools. Prior to this integration, the average number of pregnant women that were counseled, tested and received results was 200 pregnant women across all the 25 health facilities monthly. After the integration of TBAs into the program, the number of pregnant women that were counseled, tested and received results kept increasing month after month up to an average of 1500 pregnant women per month across the 25 health facilities. TBAs can thus play a key role in improving service uptake and utilization for pregnant women at primary health centers in the community - especially in the context of HIV/AIDS. They thus need to be integrated, rather than alienated, from primary healthcare service delivery.

  11. Challenges with implementing malaria rapid diagnostic tests at primary care facilities in a Ghanaian district: a qualitative study.

    PubMed

    Boadu, Nana Yaa; Amuasi, John; Ansong, Daniel; Einsiedel, Edna; Menon, Devidas; Yanow, Stephanie K

    2016-02-27

    Rapid diagnostic Tests (RDTs) for malaria enable diagnostic testing at primary care facilities in resource-limited settings, where weak infrastructure limits the use of microscopy. In 2010, Ghana adopted a test-before-treat guideline for malaria, with RDT use promoted to facilitate diagnosis. Yet healthcare practitioners still treat febrile patients without testing, or despite negative malaria test results. Few studies have explored RDT implementation beyond the notions of provider or patient acceptability. The aim of this study was to identify the factors directly influencing malaria RDT implementation at primary care facilities in a Ghanaian district. Qualitative interviews, focus groups and direct observations were conducted with 50 providers at six purposively selected primary care facilities in the Atwima-Nwabiagya district. Data were analysed thematically. RDT implementation was hampered by: (1) healthcare delivery constraints (weak supply chain, limited quality assurance and control, inadequate guideline emphasis, staffing limitations); (2) provider perceptions (entrenched case-management paradigms, limited preparedness for change); (3) social dynamics of care delivery (expected norms of provider-patient interaction, test affordability); and (4) limited provider engagement in policy processes leading to fragmented implementation of health sector reform. Limited health system capacity, socio-economic, political, and historical factors hampered malaria RDT implementation at primary care facilities in the study district. For effective RDT implementation providers must be: (1) adequately enabled through efficient allocation and management of essential healthcare commodities; (2) appropriately empowered with the requisite knowledge and skill through ongoing, effective professional development; and (3) actively engaged in policy dialogue to demystify socio-political misconceptions that hinder health sector reform policies from improving care delivery. Clear, consistent guideline emphasis, with complementary action to address deep-rooted provider concerns will build their confidence in, and promote uptake of recommended policies, practices, and technology for diagnosing malaria.

  12. Knowledge and Adherence to the National Guidelines for Malaria Diagnosis in Pregnancy among Health-Care Providers and Drug-Outlet Dispensers in Rural Western Kenya.

    PubMed

    Riley, Christina; Dellicour, Stephanie; Ouma, Peter; Kioko, Urbanus; Omar, Ahmeddin; Kariuki, Simon; Ng'ang'a, Zipporah; Desai, Meghna; Buff, Ann M; Gutman, Julie R

    2018-05-01

    Prompt diagnosis and effective treatment of acute malaria in pregnancy (MiP) is important for the mother and fetus; data on health-care provider adherence to diagnostic guidelines in pregnancy are limited. From September to November 2013, a cross-sectional survey was conducted in 51 health facilities and 39 drug outlets in Western Kenya. Provider knowledge of national diagnostic guidelines for uncomplicated MiP were assessed using standardized questionnaires. The use of parasitologic testing was assessed in health facilities via exit interviews with febrile women of childbearing age and in drug outlets via simulated-client scenarios, posing as pregnant women or their spouses. Overall, 93% of providers tested for malaria or accurately described signs and symptoms consistent with clinical malaria. Malaria was parasitologically confirmed in 77% of all patients presenting with febrile illness at health facilities and 5% of simulated clients at drug outlets. Parasitological testing was available in 80% of health facilities; 92% of patients evaluated at these facilities were tested. Only 23% of drug outlets had malaria rapid diagnostic tests (RDTs); at these outlets, RDTs were offered in 17% of client simulations. No differences were observed in testing rates by pregnancy trimester. The study highlights gaps among health providers in diagnostic knowledge and practice related to MiP, and the lack of malaria diagnostic capacity, particularly in drug outlets. The most important factor associated with malaria testing of pregnant women was the availability of diagnostics at the point of service. Interventions that increase the availability of malaria diagnostic services might improve malaria case management in pregnant women.

  13. A History of Full-Scale Aircraft and Rotorcraft Crash Testing and Simulation at NASA Langley Research Center

    NASA Technical Reports Server (NTRS)

    Jackson, Karen E.; Boitnott, Richard L.; Fasanella, Edwin L.; Jones, Lisa E.; Lyle, Karen H.

    2004-01-01

    This paper summarizes 2-1/2 decades of full-scale aircraft and rotorcraft crash testing performed at the Impact Dynamics Research Facility (IDRF) located at NASA Langley Research Center in Hampton, Virginia. The IDRF is a 240-ft.-high steel gantry that was built originally as a lunar landing simulator facility in the early 1960's. It was converted into a full-scale crash test facility for light aircraft and rotorcraft in the early 1970 s. Since the first full-scale crash test was preformed in February 1974, the IDRF has been used to conduct: 41 full-scale crash tests of General Aviation (GA) aircraft including landmark studies to establish baseline crash performance data for metallic and composite GA aircraft; 11 full-scale crash tests of helicopters including crash qualification tests of the Bell and Sikorsky Advanced Composite Airframe Program (ACAP) prototypes; 48 Wire Strike Protection System (WSPS) qualification tests of Army helicopters; 3 vertical drop tests of Boeing 707 transport aircraft fuselage sections; and, 60+ crash tests of the F-111 crew escape module. For some of these tests, nonlinear transient dynamic codes were utilized to simulate the impact response of the airframe. These simulations were performed to evaluate the capabilities of the analytical tools, as well as to validate the models through test-analysis correlation. In September 2003, NASA Langley closed the IDRF facility and plans are underway to demolish it in 2007. Consequently, it is important to document the contributions made to improve the crashworthiness of light aircraft and rotorcraft achieved through full-scale crash testing and simulation at the IDRF.

  14. Recent Enhancements to the National Transonic Facility

    NASA Technical Reports Server (NTRS)

    Kilgore, W. A.; Balakrishna, S.; Bobbitt, C. W.; Underwood, P.

    2003-01-01

    The National Transonic Facility continues to make enhancements to provide quality data in a safe, efficient and cost effective method for aerodynamic ground testing. Recent enhancements discussed in this paper include the restoration of reliability and improved performance of the heat exchanger systems resulting in the expansion of the NTF air operations envelope. Additionally, results are presented from a continued effort to reduce model dynamics through the use of a new stiffer balance and sting

  15. Fever case management at private health facilities and private pharmacies on the Kenyan coast: analysis of data from two rounds of client exit interviews and mystery client visits.

    PubMed

    Poyer, Stephen; Musuva, Anne; Njoki, Nancy; Okara, Robi; Cutherell, Andrea; Sievers, Dana; Lussiana, Cristina; Memusi, Dorothy; Kiptui, Rebecca; Ejersa, Waqo; Dolan, Stephanie; Charman, Nicole

    2018-03-13

    Private sector availability and use of malaria rapid diagnostic tests (RDTs) lags behind the public sector in Kenya. Increasing channels through which quality malaria diagnostic services are available can improve access to testing and help meet the target of universal diagnostic testing. Registered pharmacies are currently not permitted to perform blood tests, and evidence of whether malaria RDTs can be used by non-laboratory private providers in line with the national malaria control guidelines is required to inform ongoing policy discussions in Kenya. Two rounds of descriptive cross-sectional exit interviews and mystery client surveys were conducted at private health facilities and registered pharmacies in 2014 and 2015, 6 and 18 months into a multi-country project to prime the private sector market for the introduction of RDTs. Data were collected on reported RDT use, medicines received and prescribed, and case management of malaria test-negative mystery clients. Analysis compared outcomes at facilities and pharmacies independently for the two survey rounds. Across two rounds, 534 and 633 clients (including patients) from 130 and 120 outlets were interviewed, and 214 and 250 mystery client visits were completed. Reported testing by any malaria diagnostic test was higher in private health facilities than registered pharmacies in both rounds (2014: 85.6% vs. 60.8%, p < 0.001; 2015: 85.3% vs. 56.3%, p < 0.001). In registered pharmacies, testing by RDT was 52.1% in 2014 and 56.3% in 2015. At least 75% of test-positive patients received artemisinin-based combination therapy (ACT) in both rounds, with no significant difference between outlet types in either round. Provision of any anti-malarial for test-negative patients ranged from 0 to 13.9% across outlet types and rounds. In 2015, mystery clients received the correct (negative) diagnosis and did not receive an anti-malarial in 75.5% of visits to private health facilities and in 78.4% of visits to registered pharmacies. Non-laboratory staff working in registered pharmacies in Kenya can follow national guidelines for diagnosis with RDTs when provided with the same level of training and supervision as private health facility staff. Performance and compliance to treatment recommendations are comparable to diagnostic testing outcomes recorded in private health facilities.

  16. National Assessment of Data Quality and Associated Systems-Level Factors in Malawi

    PubMed Central

    O'Hagan, Richael; Marx, Melissa A; Finnegan, Karen E; Naphini, Patrick; Ng'ambi, Kumbukani; Laija, Kingsley; Wilson, Emily; Park, Lois; Wachepa, Sautso; Smith, Joseph; Gombwa, Lewis; Misomali, Amos; Mleme, Tiope; Yosefe, Simeon

    2017-01-01

    ABSTRACT Background: Routine health data can guide health systems improvements, but poor quality of these data hinders use. To address concerns about data quality in Malawi, the Ministry of Health and National Statistical Office conducted a data quality assessment (DQA) in July 2016 to identify systems-level factors that could be improved. Methods: We used 2-stage stratified random sampling methods to select health centers and hospitals under Ministry of Health auspices, included those managed by faith-based entities, for this DQA. Dispensaries, village clinics, police and military facilities, tertiary-level hospitals, and private facilities were excluded. We reviewed client registers and monthly reports to verify availability, completeness, and accuracy of data in 4 service areas: antenatal care (ANC), family planning, HIV testing and counseling, and acute respiratory infection (ARI). We also conducted interviews with facility and district personnel to assess health management information system (HMIS) functioning and systems-level factors that may be associated with data quality. We compared systems and quality factors by facility characteristics using 2-sample t tests with Welch's approximation, and calculated verification ratios comparing total entries in registers to totals from summarized reports. Results: We selected 16 hospitals (of 113 total in Malawi), 90 health centers (of 466), and 16 district health offices (of 28) in 16 of Malawi's 28 districts. Nearly all registers were available and complete in health centers and district hospitals, but data quality varied across service areas; median verification ratios comparing register and report totals at health centers ranged from 0.78 (interquartile range [IQR]: 0.25, 1.07) for ARI and 0.99 (IQR: 0.82, 1.36) for family planning to 1.00 (IQR: 0.96, 1.00) for HIV testing and counseling and 1.00 (IQR: 0.80, 1.23) for ANC. More than half (60%) of facilities reported receiving a documented supervisory visit for HMIS in the prior 6 months. A recent supervision visit was associated with better availability of data (P=.05), but regular district- or central-level supervision was not. Use of data by the facility to track performance toward targets was associated with both improved availability (P=.04) and completeness of data (P=.02). Half of facilities had a full-time statistical clerk, but their presence did not improve the availability or completeness of data (P=.39 and P=.69, respectively). Conclusion: Findings indicate both strengths and weaknesses in Malawi's HMIS performance, with key weaknesses including infrequent data quality checks and unreliable supervision. Efforts to strengthen HMIS in low- and middle-income countries should be informed by similar assessments. PMID:28963173

  17. Operational Philosophy for the Advanced Test Reactor National Scientific User Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    J. Benson; J. Cole; J. Jackson

    2013-02-01

    In 2007, the Department of Energy (DOE) designated the Advanced Test Reactor (ATR) as a National Scientific User Facility (NSUF). At its core, the ATR NSUF Program combines access to a portion of the available ATR radiation capability, the associated required examination and analysis facilities at the Idaho National Laboratory (INL), and INL staff expertise with novel ideas provided by external contributors (universities, laboratories, and industry). These collaborations define the cutting edge of nuclear technology research in high-temperature and radiation environments, contribute to improved industry performance of current and future light-water reactors (LWRs), and stimulate cooperative research between user groupsmore » conducting basic and applied research. To make possible the broadest access to key national capability, the ATR NSUF formed a partnership program that also makes available access to critical facilities outside of the INL. Finally, the ATR NSUF has established a sample library that allows access to pre-irradiated samples as needed by national research teams.« less

  18. Classification of Reactor Facility Operational State Using SPRT Methods with Radiation Sensor Networks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ramirez Aviles, Camila A.; Rao, Nageswara S.

    We consider the problem of inferring the operational state of a reactor facility by using measurements from a radiation sensor network, which is deployed around the facility’s ventilation stack. The radiation emissions from the stack decay with distance, and the corresponding measurements are inherently random with parameters determined by radiation intensity levels at the sensor locations. We fuse measurements from network sensors to estimate the intensity at the stack, and use this estimate in a one-sided Sequential Probability Ratio Test (SPRT) to infer the on/off state of the reactor facility. We demonstrate the superior performance of this method over conventionalmore » majority vote fusers and individual sensors using (i) test measurements from a network of NaI sensors, and (ii) emulated measurements using radioactive effluents collected at a reactor facility stack. We analytically quantify the performance improvements of individual sensors and their networks with adaptive thresholds over those with fixed ones, by using the packing number of the radiation intensity space.« less

  19. Consolidated Laser-Induced Fluorescence Diagnostic Systems for the NASA Ames Arc Jet Facilities

    NASA Technical Reports Server (NTRS)

    Grinstead, Jay H.; Wilder, Michael C.; Porter, Barry J.; Brown, Jeffrey D.; Yeung, Dickson; Battazzo, Stephen J.; Brubaker, Timothy R.

    2016-01-01

    The spectroscopic diagnostic technique of two photon absorption laser-induced fluorescence (LIF) of atomic species for non-intrusive arc jet flow property measurement was first implemented at NASA Ames in the mid-1990s. In 2013-2014, NASA combined the agency's large-scale arc jet test capabilities at NASA Ames. Concurrent with that effort, the agency also sponsored a project to establish two comprehensive LIF diagnostic systems for the Aerodynamic Heating Facility (AHF) and Interaction Heating Facility (IHF) arc jets. The scope of the project enabled further engineering development of the existing IHF LIF system as well as the complete reconstruction of the AHF LIF system. The updated LIF systems are identical in design and capability. They represent the culmination of over 20 years of development experience in transitioning a specialized laboratory research tool into a measurement system for large-scale, high-demand test facilities. This paper will document the latest improvements of the LIF system design and demonstrations of the redeveloped AHF and IHF LIF systems.

  20. Using Spatial-Temporal Primitives to Improve Geographic Skills for Preservice Teachers

    ERIC Educational Resources Information Center

    Kaufman, Martin M.

    2004-01-01

    An exercise to help improve the geographic skills of preservice teachers was developed and tested during a six year period on over 500 students. The exercise required these students to map two arrangements of roads and facilities within a small neighborhood. A set of special-temporal primitives (place, size, shape, distance, direction,…

  1. Space station protective coating development

    NASA Technical Reports Server (NTRS)

    Pippin, H. G.; Hill, S. G.

    1989-01-01

    A generic list of Space Station surfaces and candidate material types is provided. Environmental exposures and performance requirements for the different Space Station surfaces are listed. Coating materials and the processing required to produce a viable system, and appropriate environmental simulation test facilities are being developed. Mass loss data from the original version of the atomic oxygen test chamber and the improved facility; additional environmental exposures performed on candidate materials; and materials properties measurements on candidate coatings to determine the effects of the exposures are discussed. Methodologies of production, and coating materials, used to produce the large scale demonstration articles are described. The electronic data base developed for the contract is also described. The test chamber to be used for exposure of materials to atomic oxygen was built.

  2. An automated calibration laboratory - Requirements and design approach

    NASA Technical Reports Server (NTRS)

    O'Neil-Rood, Nora; Glover, Richard D.

    1990-01-01

    NASA's Dryden Flight Research Facility (Ames-Dryden), operates a diverse fleet of research aircraft which are heavily instrumented to provide both real time data for in-flight monitoring and recorded data for postflight analysis. Ames-Dryden's existing automated calibration (AUTOCAL) laboratory is a computerized facility which tests aircraft sensors to certify accuracy for anticipated harsh flight environments. Recently, a major AUTOCAL lab upgrade was initiated; the goal of this modernization is to enhance productivity and improve configuration management for both software and test data. The new system will have multiple testing stations employing distributed processing linked by a local area network to a centralized database. The baseline requirements for the new AUTOCAL lab and the design approach being taken for its mechanization are described.

  3. The Great Plains Wind Power Test Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schroeder, John

    2014-01-30

    This multi-year, multi-faceted project was focused on the continued development of a nationally-recognized facility for the testing, characterization, and improvement of grid-connected wind turbines, integrated wind-water desalination systems, and related educational and outreach topics. The project involved numerous faculty and graduate students from various engineering departments, as well as others from the departments of Geosciences (in particular the Atmospheric Science Group) and Economics. It was organized through the National Wind Institute (NWI), which serves as an intellectual hub for interdisciplinary and transdisciplinary research, commercialization and education related to wind science, wind energy, wind engineering and wind hazard mitigation at Texasmore » Tech University (TTU). Largely executed by an academic based team, the project resulted in approximately 38 peer-reviewed publications, 99 conference presentations, the development/expansion of several experimental facilities, and two provisional patents.« less

  4. Improved diagnostic testing and malaria treatment practices in Zambia.

    PubMed

    Hamer, Davidson H; Ndhlovu, Micky; Zurovac, Dejan; Fox, Matthew; Yeboah-Antwi, Kojo; Chanda, Pascalina; Sipilinyambe, Naawa; Simon, Jonathon L; Snow, Robert W

    2007-05-23

    Improving the accuracy of malaria diagnosis with rapid antigen-detection diagnostic tests (RDTs) has been proposed as an approach for reducing overtreatment of malaria in the current era of widespread implementation of artemisinin-based combination therapy in sub-Saharan Africa. To assess the association between use of microscopy and RDT and the prescription of antimalarials. Cross-sectional, cluster sample survey, carried out between March and May 2006, of all outpatients treated during 1 working day at government and mission health facilities in 4 sentinel districts in Zambia. Proportions of patients undergoing malaria diagnostic procedures and receiving antimalarial treatment. Seventeen percent of the 104 health facilities surveyed had functional microscopy, 63% had RDTs available, and 73% had 1 or more diagnostics available. Of patients with fever (suspected malaria), 27.8% (95% confidence interval [CI], 13.1%-42.5%) treated in health facilities with malaria diagnostics were tested and 44.6% had positive test results. Of patients with negative blood smear results, 58.4% (95% CI, 36.7%-80.2%) were prescribed an antimalaria drug, as were 35.5% (95% CI, 16.0%-55.0%) of those with a negative RDT result. Of patients with fever who did not have diagnostic tests done, 65.9% were also prescribed antimalarials. In facilities with artemether-lumefantrine in stock, this antimalarial was prescribed to a large proportion of febrile patients with a positive diagnostic test result (blood smear, 75.0% [95% CI, 51.7%-98.3%]; RDT, 70.4% [95% CI, 39.3%-100.0%]), but also to some of those with a negative diagnostic test result (blood smear, 30.4% [95% CI, 8.0%-52. 9%]; RDT, 26.7% [95% CI, 5.7%-47.7%]). Despite efforts to expand the provision of malaria diagnostics in Zambia, they continue to be underused and patients with negative test results frequently receive antimalarials. Provision of new tools to reduce inappropriate use of new expensive antimalarial treatments must be accompanied by a major change in clinical treatment of patients presenting with fever but lacking evidence of malaria infection.

  5. LISA technology development using the UF precision torsion pendulum

    NASA Astrophysics Data System (ADS)

    Apple, Stephen; Chilton, Andrew; Olatunde, Taiwo; Ciani, Giacomo; Mueller, Guido; Conklin, John

    2015-04-01

    LISA will directly observe low-frequency gravitational waves emitted by sources ranging from super-massive black hole mergers to compact galactic binaries. A laser interferometer will measure picometer changes in the distances between free falling test masses separated by millions of kilometers. A test mass and its associated sensing, actuation, charge control and caging subsystems are referred to as a gravitational reference sensor (GRS). The demanding acceleration noise requirement for the LISA GRS has motivated a rigorous testing campaign in Europe and a dedicated technology mission, LISA Pathfinder, scheduled for launch in the fall of 2015. At the University of Florida we are developing a nearly thermally noise limited torsion pendulum for testing GRS technology enhancements that may improve the performance and/or reduce the cost of the LISA GRS. This experimental facility is based on the design of a similar facility at the University of Trento, and consists of a vacuum enclosed torsion pendulum that suspends mock-ups of the LISA test masses, surrounded by electrode housings. Some of the technologies that will be demonstrated by this facility include a novel TM charge control scheme based on ultraviolet LEDs, an all-optical TM position and attitude sensor, and drift mode operation. This presentation will describe the design of the torsion pendulum facility, its current acceleration noise performance, and the status of the GRS technologies under development.

  6. Development and applications of nondestructive evaluation at Marshall Space Flight Center

    NASA Technical Reports Server (NTRS)

    Whitaker, Ann F.

    1990-01-01

    A brief description of facility design and equipment, facility usage, and typical investigations are presented for the following: Surface Inspection Facility; Advanced Computer Tomography Inspection Station (ACTIS); NDE Data Evaluation Facility; Thermographic Test Development Facility; Radiographic Test Facility; Realtime Radiographic Test Facility; Eddy Current Research Facility; Acoustic Emission Monitoring System; Advanced Ultrasonic Test Station (AUTS); Ultrasonic Test Facility; and Computer Controlled Scanning (CONSCAN) System.

  7. Impact Properties of Metal Fan Containment Materials Being Evaluated for the High-Speed Civil Transport (HSCT)

    NASA Technical Reports Server (NTRS)

    1996-01-01

    Under the Enabling Propulsion Materials (EPM) program - a partnership between NASA, Pratt & Whitney, and GE Aircraft Engines - the Materials and Structures Divisions of the NASA Lewis Research Center are involved in developing a fan-containment system for the High-Speed Civil Transport (HSCT). The program calls for a baseline system to be designed by the end of 1995, with subsequent testing of innovative concepts. Five metal candidate materials are currently being evaluated for the baseline system in the Structures Division's Ballistic Impact Facility. This facility was developed to provide the EPM program with cost-efficient and timely impact test data. At the facility, material specimens are impacted at speeds up to 350 m/sec by projectiles of various sizes and shapes to assess the specimens' ability to absorb energy and withstand impact. The tests can be conducted at either room or elevated temperatures. Posttest metallographic analysis is conducted to improve understanding of the failure modes. A dynamic finite element program is used to simulate the events and both guide the testing as well as aid in designing the fan-containment system.

  8. International Space Station (ISS)

    NASA Image and Video Library

    2001-02-01

    The Marshall Space Flight Center (MSFC) is responsible for designing and building the life support systems that will provide the crew of the International Space Station (ISS) a comfortable environment in which to live and work. Scientists and engineers at the MSFC are working together to provide the ISS with systems that are safe, efficient, and cost-effective. These compact and powerful systems are collectively called the Environmental Control and Life Support Systems, or simply, ECLSS. In this photograph, the life test area on the left of the MSFC ECLSS test facility is where various subsystems and components are tested to determine how long they can operate without failing and to identify components needing improvement. Equipment tested here includes the Carbon Dioxide Removal Assembly (CDRA), the Urine Processing Assembly (UPA), the mass spectrometer filament assemblies and sample pumps for the Major Constituent Analyzer (MCA). The Internal Thermal Control System (ITCS) simulator facility (in the module in the right) duplicates the function and operation of the ITCS in the ISS U.S. Laboratory Module, Destiny. This facility provides support for Destiny, including troubleshooting problems related to the ITCS.

  9. Structural Dynamic Assessment of the GN2 Piping System for NASA's New and Powerful Reverberant Acoustic Test Facility

    NASA Technical Reports Server (NTRS)

    McNelis, Mark E.; Staab, Lucas D.; Akers, James C.; Hughes, William O.; Chang, Li C.; Hozman, Aron D.; Henry, Michael W.

    2012-01-01

    The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) has led the design and build of the new world-class vibroacoustic test capabilities at the NASA GRC's Plum Brook Station in Sandusky, Ohio, USA from 2007 to 2011. SAIC-Benham has completed construction of a new reverberant acoustic test facility to support the future testing needs of NASA's space exploration program and commercial customers. The large Reverberant Acoustic Test Facility (RATF) is approximately 101,000 cubic feet in volume and was designed to operate at a maximum empty chamber acoustic overall sound pressure level (OASPL) of 163 dB. This combination of size and acoustic power is unprecedented amongst the world s known active reverberant acoustic test facilities. Initial checkout acoustic testing was performed on March 2011 by SAIC-Benham at test levels up to 161 dB OASPL. During testing, several branches of the gaseous nitrogen (GN2) piping system, which supply the fluid to the noise generating acoustic modulators, failed at their T-junctions connecting the 12 in. supply line to their respective 4 in. branch lines. The problem was initially detected when the oxygen sensors in the horn room indicated a lower than expected oxygen level from which was inferred GN2 leaks in the piping system. In subsequent follow up inspections, cracks were identified in the failed T-junction connections through non-destructive evaluation testing. Through structural dynamic modeling of the piping system, the root cause of the T-junction connection failures was determined. The structural dynamic assessment identified several possible corrective design improvements to the horn room piping system. The effectiveness of the chosen design repairs were subsequently evaluated in September 2011 during acoustic verification testing to 161 dB OASPL.

  10. Structural Dynamic Assessment of the GN2 Piping System for NASA's New and Powerful Reverberant Acoustic Test Facility

    NASA Technical Reports Server (NTRS)

    McNelis, Mark E.; Staab, Lucas D.; Akers, James C.; Hughes, WIlliam O.; Chang, Li, C.; Hozman, Aron D.; Henry, Michael W.

    2012-01-01

    The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) has led the design and build of the new world-class vibroacoustic test capabilities at the NASA GRC's Plum Brook Station in Sandusky, Ohio, USA from 2007-2011. SAIC-Benham has completed construction of a new reverberant acoustic test facility to support the future testing needs of NASA's space exploration program and commercial customers. The large Reverberant Acoustic Test Facility (RATF) is approximately 101,000 cu ft in volume and was designed to operate at a maximum empty chamber acoustic overall sound pressure level (OASPL) of 163 dB. This combination of size and acoustic power is unprecedented amongst the world's known active reverberant acoustic test facilities. Initial checkout acoustic testing was performed on March 2011 by SAIC-Benham at test levels up to 161 dB OASPL. During testing, several branches of the gaseous nitrogen (GN2) piping system, which supply the fluid to the noise generating acoustic modulators, failed at their "t-junctions" connecting the 12 inch supply line to their respective 4 inch branch lines. The problem was initially detected when the oxygen sensors in the horn room indicated a lower than expected oxygen level from which was inferred GN2 leaks in the piping system. In subsequent follow up inspections, cracks were identified in the failed "t-junction" connections through non-destructive evaluation testing . Through structural dynamic modeling of the piping system, the root cause of the "t-junction" connection failures was determined. The structural dynamic assessment identified several possible corrective design improvements to the horn room piping system. The effectiveness of the chosen design repairs were subsequently evaluated in September 2011 during acoustic verification testing to 161 dB OASPL.

  11. Occupational dose reduction at Department of Energy contractor facilities: Bibliography of selected readings in radiation protection and ALARA; Volume 5

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dionne, B.J.; Sullivan, S.G.; Baum, J.W.

    1994-01-01

    Promoting the exchange of information related to implementation of the As Low as Reasonably Achievable (ALARA) philosophy is a continuing objective for the Department of Energy (DOE). This report was prepared by the Brookhaven National Laboratory (BNL) ALARA Center for the DOE Office of Health. It contains the fifth in a series of bibliographies on dose reduction at DOE facilities. The BNL ALARA Center was originally established in 1983 under the sponsorship of the Nuclear Regulatory Commission to monitor dose-reduction research and ALARA activities at nuclear power plants. This effort was expanded in 1988 by the DOE`s Office of Environment,more » Safety and Health, to include DOE nuclear facilities. This bibliography contains abstracts relating to various aspects of ALARA program implementation and dose-reduction activities, with a specific focus on DOE facilities. Abstracts included in this bibliography were selected from proceedings of technical meetings, journals, research reports, searches of the DOE Energy, Science and Technology Database (in general, the citation and abstract information is presented as obtained from this database), and reprints of published articles provided by the authors. Facility types and activities covered in the scope of this report include: radioactive waste, uranium enrichment, fuel fabrication, spent fuel storage and reprocessing, facility decommissioning, hot laboratories, tritium production, research, test and production reactors, weapons fabrication and testing, fusion, uranium and plutonium processing, radiography, and accelerators. Information on improved shielding design, decontamination, containments, robotics, source prevention and control, job planning, improved operational and design techniques, as well as on other topics, has been included. In addition, DOE/EH reports not included in previous volumes of the bibliography are in this volume (abstracts 611 to 684). This volume (Volume 5 of the series) contains 217 abstracts.« less

  12. Multifunctional Nanocomposites for Improved Sustainability and Protection of Facilities

    DTIC Science & Technology

    2015-05-01

    ballistic panels. In addition, the team’s work tested various options for adding self - healing , CNT reinforcement, EMI shielding, and self ...and functional- ization methods; introducing a self - healing agent directly to the matrix or contained in embedded hollow glass fibers; using layers...using CNT sheet reinforcement ...................... 23 5 Ballistic Testing of Self - Healing GFRP Panel

  13. FFTF Passive Safety Test Data for Benchmarks for New LMR Designs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wootan, David W.; Casella, Andrew M.

    Liquid Metal Reactors (LMRs) continue to be considered as an attractive concept for advanced reactor design. Software packages such as SASSYS are being used to im-prove new LMR designs and operating characteristics. Significant cost and safety im-provements can be realized in advanced liquid metal reactor designs by emphasizing inherent or passive safety through crediting the beneficial reactivity feedbacks associ-ated with core and structural movement. This passive safety approach was adopted for the Fast Flux Test Facility (FFTF), and an experimental program was conducted to characterize the structural reactivity feedback. The FFTF passive safety testing pro-gram was developed to examine howmore » specific design elements influenced dynamic re-activity feedback in response to a reactivity input and to demonstrate the scalability of reactivity feedback results to reactors of current interest. The U.S. Department of En-ergy, Office of Nuclear Energy Advanced Reactor Technology program is in the pro-cess of preserving, protecting, securing, and placing in electronic format information and data from the FFTF, including the core configurations and data collected during the passive safety tests. Benchmarks based on empirical data gathered during operation of the Fast Flux Test Facility (FFTF) as well as design documents and post-irradiation examination will aid in the validation of these software packages and the models and calculations they produce. Evaluation of these actual test data could provide insight to improve analytical methods which may be used to support future licensing applications for LMRs« less

  14. Evaluation of the NASA Ames no. 1 7 by 10 foot wind tunnel as an acoustic test facility

    NASA Technical Reports Server (NTRS)

    Wilby, J. F.; Scharton, T. D.

    1975-01-01

    Measurements were made in the no. 1 7'x10' wind tunnel at NASA Ames Research Center, with the objectives of defining the acoustic characteristics and recommending minimum cost treatments so that the tunnel can be converted into an acoustic research facility. The results indicate that the noise levels in the test section are due to (a) noise generation in the test section, associated with the presence of solid bodies such as the pitot tube, and (b) propagation of acoustic energy from the fan. A criterion for noise levels in the test section is recommended, based on low-noise microphone support systems. Noise control methods required to meet the criterion include removal of hardware items for the test section and diffuser, improved design of microphone supports, and installation of acoustic treatment in the settling chamber and diffuser.

  15. Development of a Daily Life Support System for Elderly Persons with Dementia in the Care Facility.

    PubMed

    Takahashi, Yoshiyuki; Kawai, Toshihiro; Komeda, Takashi

    2015-01-01

    Taking care for dementia persons with BPSD is burdening on caregivers. To reduce caregivers' burdens and improve dementia persons' quality of life, monitoring and communication intervention system has been proposed. A part of the system, wandering and falling down detection system has been developed. It is designed based on the requirement of the caregivers working in the care facility. Functional test was carried out and had positive impressions from the caregivers.

  16. Effects assessment of 10 functioning years on the main components of the molten salt PCS experimental facility of ENEA

    NASA Astrophysics Data System (ADS)

    Gaggioli, Walter; Di Ascenzi, Primo; Rinaldi, Luca; Tarquini, Pietro; Fabrizi, Fabrizio

    2016-05-01

    In the frame of the Solar Thermodynamic Laboratory, ENEA has improved CSP Parabolic Trough technologies by adopting new advanced solutions for linear tube receivers and by implementing a binary mixture of molten salt (60% NaNO3 and 40% KNO3) [1] as both heat transfer fluid and heat storage medium in solar field and in storage tanks, thus allowing the solar plants to operate at high temperatures up to 550°C. Further improvements have regarded parabolic mirror collectors, piping and process instrumentation. All the innovative components developed by ENEA, together with other standard parts of the plant, have been tested and qualified under actual solar operating conditions on the PCS experimental facility at the ENEA Casaccia Research Center in Rome (Italy). The PCS (Prova Collettori Solari, i.e. Test of Solar Collectors) facility is the main testing loop built by ENEA and it is unique in the world for what concerns the high operating temperature and the fluid used (mixture of molten salt). It consists in one line of parabolic trough collectors (test section of 100 m long life-size solar collectors) using, as heat transfer fluid, the aforesaid binary mixture of molten salt up to 10 bar, at high temperature in the range 270° and 550°C and a flow rate up to 6.5 kg/s. It has been working since early 2004 [2] till now; it consists in a unique closed loop, and it is totally instrumented. In this paper the effects of over ten years qualification tests on the pressurized tank will be presented, together with the characterization of the thermal losses of the piping of the molten salt circuit, and some observations performed on the PCS facility during its first ten years of operation.

  17. An Overview of Facilities and Capabilities to Support the Development of Nuclear Thermal Propulsion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    James Werner; Sam Bhattacharyya; Mike Houts

    Abstract. The future of American space exploration depends on the ability to rapidly and economically access locations of interest throughout the solar system. There is a large body of work (both in the US and the Former Soviet Union) that show that Nuclear Thermal Propulsion (NTP) is the most technically mature, advanced propulsion system that can enable this rapid and economical access by its ability to provide a step increase above what is a feasible using a traditional chemical rocket system. For an NTP system to be deployed, the earlier measurements and recent predictions of the performance of the fuelmore » and the reactor system need to be confirmed experimentally prior to launch. Major fuel and reactor system issues to be addressed include fuel performance at temperature, hydrogen compatibility, fission product retention, and restart capability. The prime issue to be addressed for reactor system performance testing involves finding an affordable and environmentally acceptable method to test a range of engine sizes using a combination of nuclear and non-nuclear test facilities. This paper provides an assessment of some of the capabilities and facilities that are available or will be needed to develop and test the nuclear fuel, and reactor components. It will also address briefly options to take advantage of the greatly improvement in computation/simulation and materials processing capabilities that would contribute to making the development of an NTP system more affordable. Keywords: Nuclear Thermal Propulsion (NTP), Fuel fabrication, nuclear testing, test facilities.« less

  18. Malaria prevalence and treatment of febrile patients at health facilities and medicine retailers in Cameroon.

    PubMed

    Mangham, Lindsay J; Cundill, Bonnie; Achonduh, Olivia A; Ambebila, Joel N; Lele, Albertine K; Metoh, Theresia N; Ndive, Sarah N; Ndong, Ignatius C; Nguela, Rachel L; Nji, Akindeh M; Orang-Ojong, Barnabas; Wiseman, Virginia; Pamen-Ngako, Joelle; Mbacham, Wilfred F

    2012-03-01

    To investigate the quality of malaria case management in Cameroon 5 years after the adoption of artemisinin-based combination therapy (ACT). Treatment patterns were examined in different types of facility, and the factors associated with being prescribed or receiving an ACT were investigated. A cross-sectional cluster survey was conducted among individuals of all ages who left public and private health facilities and medicine retailers in Cameroon and who reported seeking treatment for a fever. Prevalence of malaria was determined by rapid diagnostic tests (RDTs) in consenting patients attending the facilities and medicine retailers. Among the patients, 73% were prescribed or received an antimalarial, and 51% were prescribed or received an ACT. Treatment provided to patients significantly differed by type of facility: 65% of patients at public facilities, 55% of patients at private facilities and 45% of patients at medicine retailers were prescribed or received an ACT (P = 0.023). The odds of a febrile patient being prescribed or receiving an ACT were significantly higher for patients who asked for an ACT (OR = 24.1, P < 0.001), were examined by the health worker (OR = 1.88, P = 0.021), had not previously sought an antimalarial for the illness (OR = 2.29, P = 0.001) and sought treatment at a public (OR = 3.55) or private facility (OR = 1.99, P = 0.003). Malaria was confirmed in 29% of patients and 70% of patients with a negative result were prescribed or received an antimalarial. Malaria case management could be improved. Symptomatic diagnosis is inefficient because two-thirds of febrile patients do not have malaria. Government plans to extend malaria testing should promote rational use of ACT; though, the introduction of rapid diagnostic testing needs to be accompanied by updated clinical guidelines that provide clear guidance for the treatment of patients with negative test results. © 2011 Blackwell Publishing Ltd.

  19. Mobile HIV screening in Cape Town, South Africa: clinical impact, cost and cost-effectiveness.

    PubMed

    Bassett, Ingrid V; Govindasamy, Darshini; Erlwanger, Alison S; Hyle, Emily P; Kranzer, Katharina; van Schaik, Nienke; Noubary, Farzad; Paltiel, A David; Wood, Robin; Walensky, Rochelle P; Losina, Elena; Bekker, Linda-Gail; Freedberg, Kenneth A

    2014-01-01

    Mobile HIV screening may facilitate early HIV diagnosis. Our objective was to examine the cost-effectiveness of adding a mobile screening unit to current medical facility-based HIV testing in Cape Town, South Africa. We used the Cost Effectiveness of Preventing AIDS Complications International (CEPAC-I) computer simulation model to evaluate two HIV screening strategies in Cape Town: 1) medical facility-based testing (the current standard of care) and 2) addition of a mobile HIV-testing unit intervention in the same community. Baseline input parameters were derived from a Cape Town-based mobile unit that tested 18,870 individuals over 2 years: prevalence of previously undiagnosed HIV (6.6%), mean CD4 count at diagnosis (males 423/µL, females 516/µL), CD4 count-dependent linkage to care rates (males 31%-58%, females 49%-58%), mobile unit intervention cost (includes acquisition, operation and HIV test costs, $29.30 per negative result and $31.30 per positive result). We conducted extensive sensitivity analyses to evaluate input uncertainty. Model outcomes included site of HIV diagnosis, life expectancy, medical costs, and the incremental cost-effectiveness ratio (ICER) of the intervention compared to medical facility-based testing. We considered the intervention to be "very cost-effective" when the ICER was less than South Africa's annual per capita Gross Domestic Product (GDP) ($8,200 in 2012). We projected that, with medical facility-based testing, the discounted (undiscounted) HIV-infected population life expectancy was 132.2 (197.7) months; this increased to 140.7 (211.7) months with the addition of the mobile unit. The ICER for the mobile unit was $2,400/year of life saved (YLS). Results were most sensitive to the previously undiagnosed HIV prevalence, linkage to care rates, and frequency of HIV testing at medical facilities. The addition of mobile HIV screening to current testing programs can improve survival and be very cost-effective in South Africa and other resource-limited settings, and should be a priority.

  20. CMIF ECLS system test findings

    NASA Technical Reports Server (NTRS)

    Schunk, Richard G.; Carrasquillo, Robyn L.; Ogle, Kathyrn Y.; Wieland, Paul O.; Bagdigian, Robert M.

    1989-01-01

    During 1987 three Space Station integrated Environmental Control and Life Support System (ECLSS) tests were conducted at the Marshall Space Flight Center (MSFC) Core Module Integration Facility (CMIF) as part of the MSFC ECLSS Phase II test program. The three tests ranged in duration from 50 to 150 hours and were conducted inside of the CMIF module simulator. The Phase II partial integrated system test configuration consisted of four regenerative air revitalization subsystems and one regenerative water reclamation subsystem. This paper contains a discussion of results and lessons learned from the Phase II test program. The design of the Phase II test configuration and improvements made throughout the program are detailed. Future plans for the MSFC CMIF test program are provided, including an overview of planned improvements for the Phase III program.

  1. Using Spacelab as a precursor of science operations for the Space Station

    NASA Technical Reports Server (NTRS)

    Marmann, R. A.

    1997-01-01

    For more than 15 years, Spacelab, has provided a laboratory in space for an international array of experiments, facilities, and experimenters. In addition to continuing this important work, Spacelab is now serving as a crucial stepping-stone to the improved science, improved operations, and rapid access to space that will characterize International Space Station. In the Space Station era, science operations will depend primarily on distributed/remote operations that will allow investigators to direct science activities from their universities, facilities, or home bases. Spacelab missions are a crucial part of preparing for these activities, having been used to test, prove, and refine remote operations over several missions. The knowledge gained from preparing these Missions is also playing a crucial role in reducing the time required to put an experiment into orbit, from revolutionizing the processes involved to testing the hardware needed for these more advanced operations. This paper discusses the role of the Spacelab program and the NASA Marshall Space Flight Center- (MSFC-) managed missions in developing and refining remote operations, new hardware and facilities for use on Space Station, and procedures that dramatically reduce preparation time for flight.

  2. Measuring The Impact Of Cash Transfers And Behavioral 'Nudges' On Maternity Care In Nairobi, Kenya.

    PubMed

    Cohen, Jessica; Rothschild, Claire; Golub, Ginger; Omondi, George N; Kruk, Margaret E; McConnell, Margaret

    2017-11-01

    Many patients in low-income countries express preferences for high-quality health care but often end up with low-quality providers. We conducted a randomized controlled trial with pregnant women in Nairobi, Kenya, to analyze whether cash transfers, enhanced with behavioral "nudges," can help women deliver in facilities that are consistent with their preferences and are of higher quality. We tested two interventions. The first was a labeled cash transfer (LCT), which explained that the cash was to help women deliver where they wanted. The second was a cash transfer that combined labeling and a commitment by the recipient to deliver in a prespecified desired facility as a condition of receiving the final payment (L-CCT). The L-CCT improved patient-perceived quality of interpersonal care but not perceived technical quality of care. It also increased women's likelihood of delivering in facilities that met standards for routine and emergency newborn care but not the likelihood of delivering in facilities that met standards for obstetric care. The LCT had fewer measured benefits. Women preferred facilities with high technical and interpersonal care quality, but these quality measures were often negatively correlated within facilities. Even with cash transfers, many women still used poor-quality facilities. A larger study is warranted to determine whether the L-CCT can improve maternal and newborn outcomes.

  3. [Physical improvements and rising motivation following the "school style" technique in the residents of a nursing home].

    PubMed

    Shiota, Kozue; Goto, Shinichi; Tanenaga, Satoshi; Koyama, Keiko

    2014-01-01

    After five years of using our unique "school style" technique, we were able to increase the number of home discharges and decrease the number of days spent in the facility. In order to identify the factors underlying these results, a survey was conducted regarding changes of the physical and cognitive function while in the facility. The subjects included 41 patients who newly began using our facility. All subjects participated in both group and individual programs and were evaluated using the Mini Mental State Examination (MMSE), Frontal Assessment Battery at the bedside (FAB), Vitality Index and Functional Independence Measure (FIM) determined monthly starting the first day of entry into our facility. We compared the results using the Friedman test. The rate of participation in the group program was 81.9%. The average duration of participation in functional training as an individual program was 5.94 days, while that for Kumon learning therapy was 3.27 days. Effective improvements were noted in all four evaluation measurements: MMSE・FAB・Vitality Index・FIM. Improvements in the physical and cognitive function were obtained despite the status of the subjects as elderly individuals with chronic disease. Against this background, we applied interventions with rehabilitation using an intensive program for individuals and noted a pleasant experience during all activities in our unique "school style" protocol, which seeks to improve the subject's motivation. These factors are therefore important for improving the physical and cognitive function.

  4. Design and Test of an Improved Crashworthiness Small Composite Airframe

    NASA Technical Reports Server (NTRS)

    Terry, James E.; Hooper, Steven J.; Nicholson, Mark

    2002-01-01

    The purpose of this small business innovative research (SBIR) program was to evaluate the feasibility of developing small composite airplanes with improved crashworthiness. A combination of analysis and half scale component tests were used to develop an energy absorbing airframe. Four full scale crash tests were conducted at the NASA Impact Dynamics Research Facility, two on a hard surface and two onto soft soil, replicating earlier NASA tests of production general aviation airplanes. Several seat designs and restraint systems including both an air bag and load limiting shoulder harnesses were tested. Tests showed that occupant loads were within survivable limits with the improved structural design and the proper combination of seats and restraint systems. There was no loss of cabin volume during the events. The analysis method developed provided design guidance but time did not allow extending the analysis to soft soil impact. This project demonstrated that survivability improvements are possible with modest weight penalties. The design methods can be readily applied by airplane designers using the examples in this report.

  5. Data acquisition and PV module power production in upgraded TEP/AzRISE solar test yard

    NASA Astrophysics Data System (ADS)

    Bennett, Whit E.; Fishgold, Asher D.; Lai, Teh; Potter, Barrett G.; Simmons-Potter, Kelly

    2017-08-01

    The Tucson Electric Power (TEP)/University of Arizona AzRISE (Arizona Research Institute for Solar Energy) solar test yard is continuing efforts to improve standardization and data acquisition reliability throughout the facility. Data reliability is ensured through temperature-insensitive data acquisition devices with battery backups in the upgraded test yard. Software improvements allow for real-time analysis of collected data, while uploading to a web server. Sample data illustrates high fidelity monitoring of the burn-in period of a polycrystalline silicon photovoltaic module test string with no data failures over 365 days of data collection. In addition to improved DAQ systems, precision temperature monitoring has been implemented so that PV module backside temperatures are routinely obtained. Weather station data acquired at the test yard provides local ambient temperature, humidity, wind speed, and irradiance measurements that have been utilized to enable characterization of PV module performance over an extended test period

  6. Continuous Improvement in Battery Testing at the NASA/JSC Energy System Test Area

    NASA Technical Reports Server (NTRS)

    Boyd, William; Cook, Joseph

    2003-01-01

    The Energy Systems Test Area (ESTA) at the Lyndon B. Johnson Space Center in Houston, Texas conducts development and qualification tests to fulfill Energy System Division responsibilities relevant to ASA programs and projects. EST A has historically called upon a variety of fluid, mechanical, electrical, environmental, and data system capabilities spread amongst five full-service facilities to test human and human supported spacecraft in the areas of propulsion systems, fluid systems, pyrotechnics, power generation, and power distribution and control systems. Improvements at ESTA are being made in full earnest of offering NASA project offices an option to choose a thorough test regime that is balanced with cost and schedule constraints. In order to continue testing of enabling power-related technologies utilized by the Energy System Division, an especially proactive effort has been made to increase the cost effectiveness and schedule responsiveness for battery testing. This paper describes the continuous improvement in battery testing at the Energy Systems Test Area being made through consolidation, streamlining, and standardization.

  7. The Nature of Scatter at the DARHT Facility and Suggestions for Improved Modeling of DARHT Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morneau, Rachel Anne; Klasky, Marc Louis

    The U.S. Stockpile Stewardship Program [1] is designed to sustain and evaluate the nuclear weapons stockpile while foregoing underground nuclear tests. The maintenance of a smaller, aging U.S. nuclear weapons stockpile without underground testing requires complex computer calculations [14]. These calculations in turn need to be verified and benchmarked [14]. A wide range of research facilities have been used to test and evaluate nuclear weapons while respecting the Comprehensive Nuclear Test-Ban Treaty (CTBT) [2]. Some of these facilities include the National Ignition Facility (NIF) at Lawrence Livermore National Laboratory, the Z machine at Sandia National Laboratories, and the Dual Axismore » Radiographic Hydrodynamic Test (DARHT) facility at Los Alamos National Laboratory. This research will focus largely on DARHT (although some information from Cygnus and the Los Alamos Microtron may be used in this research) by modeling it and comparing to experimental data. DARHT is an electron accelerator that employs high-energy flash x-ray sources for imaging hydro-tests. This research proposes to address some of the issues crucial to understanding DARHT Axis II and the analysis of the radiographic images produced. Primarily, the nature of scatter at DARHT will be modeled and verified with experimental data. It will then be shown that certain design decisions can be made to optimize the scatter field for hydrotest experiments. Spectral effects will be briefly explored to determine if there is any considerable effect on the density reconstruction caused by changes in the energy spectrum caused by target changes. Finally, a generalized scatter model will be made using results from MCNP that can be convolved with the direct transmission of an object to simulate the scatter of that object at the detector plane. The region in which with this scatter model is appropriate will be explored.« less

  8. Effect of integrated infectious disease training and on-site support on the management of childhood illnesses in Uganda: a cluster randomized trial.

    PubMed

    Imani, Peace; Jakech, Brian; Kirunda, Ibrahim; Mbonye, Martin K; Naikoba, Sarah; Weaver, Marcia R

    2015-08-28

    The Integrated Infectious Disease Capacity-Building Evaluation (IDCAP) was designed to test the effects of two interventions, Integrated Management of Infectious Disease (IMID) training and on-site support (OSS), on clinical practice of mid-level practitioners. This article reports the effects of these interventions on clinical practice in management of common childhood illnesses. Two trainees from each of 36 health facilities participated in the IMID training. IMID was a three-week core course, two one-week boost courses, and distance learning over nine months. Eighteen of the 36 health facilities were then randomly assigned to arm A, and participated in OSS, while the other 18 health facilities assigned to arm B did not. Clinical faculty assessed trainee practice on clinical practice of six sets of tasks: patient history, physical examination, laboratory tests, diagnosis, treatment, and patient/caregiver education. The effects of IMID were measured by the post/pre adjusted relative risk (aRR) of appropriate practice in arm B. The incremental effects of OSS were measured by the adjusted ratio of relative risks (aRRR) in arm A compared to arm B. All hypotheses were tested at a 5% level of significance. Patient samples were comparable across arms at baseline and endline. The majority of children were aged under five years; 84% at baseline and 97% at endline. The effects of IMID on patient history (aRR = 1.12; 95% CI = 1.04-1.21) and physical examination (aRR = 1.40; 95% CI = 1.16-1.68) tasks were statistically significant. OSS was associated with incremental improvement in patient history (aRRR = 1.18; 95% CI = 1.06-1.31), and physical examination (aRRR = 1.27; 95% CI = 1.02-1.59) tasks. Improvements in laboratory testing, diagnosis, treatment, and patient/caregiver education were not statistically significant. IMID training was associated with improved patient history taking and physical examination, and OSS further improved these clinical practices. On-site training and continuous quality improvement activities support transfer of learning to practice among mid-level practitioners.

  9. Water monitor system: Phase 1 test report

    NASA Technical Reports Server (NTRS)

    Taylor, R. E.; Jeffers, E. L.

    1976-01-01

    Automatic water monitor system was tested with the objectives of assuring high-quality effluent standards and accelerating the practice of reclamation and reuse of water. The NASA water monitor system is described. Various components of the system, including the necessary sensors, the sample collection system, and the data acquisition and display system, are discussed. The test facility and the analysis methods are described. Test results are reviewed, and recommendations for water monitor system design improvement are presented.

  10. Evaluating the effectiveness of a strategy for teaching neonatal resuscitation in West Africa.

    PubMed

    Enweronu-Laryea, Christabel; Engmann, Cyril; Osafo, Alexandra; Bose, Carl

    2009-11-01

    To evaluate the effectiveness of a strategy for teaching neonatal resuscitation on the cognitive knowledge of health professionals who attend deliveries in Ghana, West Africa. Train-the-trainer model was used to train health professionals at 2-3 day workshops from 2003 to 2007. Obstetric Anticipatory Care and Basic Neonatal Care modules were taught as part of Neonatal Resuscitation Training package. American Neonatal Resuscitation Program was adapted to the clinical role of participants and local resources. Cognitive knowledge was evaluated by written pre- and post-training tests. The median pre-training and post-training scores were 38% and 71% for midwives, 43% and 81% for nurses, 52% and 90% for nurse anaesthetists, and 62% and 98% for physicians. All groups of the 271 professionals (18 nurse anaesthetists, 55 nurses, 68 physicians, and 130 midwives) who completed the course showed significant improvement (p<0.001) in median post-training test scores. Midwives at primary health care facilities were less likely to achieve passing post-test scores than midwives at secondary and tertiary facilities [35/53 vs. 24/26 vs. 45/51 (p=0.004)] respectively. Evidence-based neonatal resuscitation training adapted to local resources significantly improved cognitive knowledge of all groups of health professionals. Further modification of training for midwives working at primary level health facilities and incorporation of neonatal resuscitation in continuing education and professional training programs are recommended.

  11. NeuroRecovery Network provides standardization of locomotor training for persons with incomplete spinal cord injury.

    PubMed

    Morrison, Sarah A; Forrest, Gail F; VanHiel, Leslie R; Davé, Michele; D'Urso, Denise

    2012-09-01

    To illustrate the continuity of care afforded by a standardized locomotor training program across a multisite network setting within the Christopher and Dana Reeve Foundation NeuroRecovery Network (NRN). Single patient case study. Two geographically different hospital-based outpatient facilities. This case highlights a 25-year-old man diagnosed with C4 motor incomplete spinal cord injury with American Spinal Injury Association Impairment Scale grade D. Standardized locomotor training program 5 sessions per week for 1.5 hours per session, for a total of 100 treatment sessions, with 40 sessions at 1 center and 60 at another. Ten-meter walk test and 6-minute walk test were assessed at admission and discharge across both facilities. For each of the 100 treatment sessions percent body weight support, average, and maximum treadmill speed were evaluated. Locomotor endurance, as measured by the 6-minute walk test, and overground gait speed showed consistent improvement from admission to discharge. Throughout training, the patient decreased the need for body weight support and was able to tolerate faster treadmill speeds. Data indicate that the patient continued to improve on both treatment parameters and walking function. Standardization across the NRN centers provided a mechanism for delivering consistent and reproducible locomotor training programs across 2 facilities without disrupting training or recovery progression. Copyright © 2012 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  12. Acute hepatitis B outbreaks in 2 skilled nursing facilities and possible sources of transmission: North Carolina, 2009-2010.

    PubMed

    Seña, Arlene C; Moorman, Anne; Njord, Levi; Williams, Roxanne E; Colborn, James; Khudyakov, Yury; Drobenuic, Jan; Xia, Guo-Liang; Wood, Hattie; Moore, Zack

    2013-07-01

    Acute hepatitis B virus (HBV) infections have been reported in long-term care facilities (LTCFs), primarily associated with infection control breaks during assisted blood glucose monitoring. We investigated HBV outbreaks that occurred in separate skilled nursing facilities (SNFs) to determine factors associated with transmission. Outbreak investigation with case-control studies. Two SNFs (facilities A and B) in Durham, North Carolina, during 2009-2010. Residents with acute HBV infection and controls randomly selected from HBV-susceptible residents during the outbreak period. After initial cases were identified, screening was offered to all residents, with repeat testing 3 months later for HBV-susceptible residents. Molecular testing was performed to assess viral relatedness. Infection control practices were observed. Case-control studies were conducted to evaluate associations between exposures and acute HBV infection in each facility. Six acute HBV cases were identified in each SNF. Viral phylogenetic analysis revealed a high degree of HBV relatedness within, but not between, facilities. No evaluated exposures were significantly associated with acute HBV infection in facility A; those associated with infection in facility B (all odds ratios >20) included injections, hospital or emergency room visits, and daily blood glucose monitoring. Observations revealed absence of trained infection control staff at facility A and suboptimal hand hygiene practices during blood glucose monitoring and insulin injections at facility B. These outbreaks underscore the vulnerability of LTCF residents to acute HBV infection, the importance of surveillance and prompt investigation of incident cases, and the need for improved infection control education to prevent transmission.

  13. The drivers of facility-based immunization performance and costs. An application to Moldova.

    PubMed

    Maceira, Daniel; Goguadze, Ketevan; Gotsadze, George

    2015-05-07

    This paper identifies factors that affect the cost and performance of the routine immunization program in Moldova through an analysis of facility-based data collected as part of a multi-country costing and financing study of routine immunization (EPIC). A nationally representative sample of health care facilities (50) was selected through multi-stage, stratified random sampling. Data on inputs, unit prices and facility outputs were collected during October 3rd 2012-January 14th 2013 using a pre-tested structured questionnaire. Ordinary least square (OLS) regression analysis was performed to determine factors affecting facility outputs (number of doses administered and fully immunized children) and explaining variation in total facility costs. The study found that the number of working hours, vaccine wastage rates, and whether or not a doctor worked at a facility (among other factors) were positively and significantly associated with output levels. In addition, the level of output, price of inputs and share of the population with university education were significantly associated with higher facility costs. A 1% increase in fully immunized child would increase total cost by 0.7%. Few costing studies of primary health care services in developing countries evaluate the drivers of performance and cost. This exercise attempted to fill this knowledge gap and helped to identify organizational and managerial factors at a primary care district and national level that could be addressed by improved program management aimed at improved performance. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Addressing social aspects associated with wastewater treatment facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Padilla-Rivera, Alejandro; Morgan-Sagastume, Juan Manuel; Noyola, Adalberto

    In wastewater treatment facilities (WWTF), technical and financial aspects have been considered a priority, while other issues, such as social aspects, have not been evaluated seriously and there is not an accepted methodology for assessing it. In this work, a methodology focused on social concerns related to WWTF is presented. The methodology proposes the use of 25 indicators as a framework for measuring social performance to evaluate the progress in moving towards sustainability. The methodology was applied to test its applicability and effectiveness in two WWTF in Mexico (urban and rural). This evaluation helped define the key elements, stakeholders andmore » barriers in the facilities. In this context, the urban facility showed a better overall performance, a result that may be explained mainly by the better socioeconomic context of the urban municipality. Finally, the evaluation of social aspects using the semi-qualitative approach proposed in this work allows for a comparison between different facilities and for the identification of strengths and weakness, and it provides an alternative tool for achieving and improving wastewater management. - Highlights: • The methodology proposes 25 indicators as a framework for measuring social performance in wastewater treatment facilities. • The evaluation helped to define the key elements, stakeholders and barriers in the wastewater treatment facilities. • The evaluation of social aspects allows the identification of strengths and weakness for improving wastewater management. • It provides a social profile of the facility that highlights the best and worst performances.« less

  15. Improving Ebola infection prevention and control in primary healthcare facilities in Sierra Leone: a single-group pretest post-test, mixed-methods study.

    PubMed

    Ratnayake, Ruwan; Ho, Lara S; Ansumana, Rashid; Brown, Hannah; Borchert, Matthias; Miller, Laura; Kratz, Thomas; McMahon, Shannon A; Sahr, Foday

    2016-01-01

    Accomplishing infection prevention and control (IPC) in health facilities in Sub-Saharan Africa is challenging. Owing to poor IPC, healthcare workers (HCWs) were frequently infected during Sierra Leone's Ebola epidemic. In late 2014, IPC was rapidly and nationally scaled up. We carried out workshops in sampled facilities to further improve adherence to IPC. We investigated HCW experiences and observed practice gaps, before and after the workshops. We conducted an uncontrolled, before and after, mixed-methods study in eight health facilities in Bo and Kenema Districts during December 2014 and January 2015. Quantitative methods administered to HCWs at baseline and follow-up included a survey on attitudes and self-efficacy towards IPC, and structured observations of behaviours. The intervention involved a workshop for HCWs to develop improvement plans for their facility. We analysed the changes between rounds in survey responses and behaviours. We used interviews to explore attitudes and self-efficacy throughout the study period. HCWs described IPC as 'life-saving' and personal protective equipment (PPE) as uncomfortable for providers and frightening for patients. At baseline, self-efficacy was high (median=4/strongly agree). Responses reflecting unfavourable attitudes were low for glove use (median=1/strongly disagree, IQR, 1-2) and PPE use with ill family members (median=1, IQR, 1-2), and mixed for PPE use with ill HCWs (median=2/disagree, IQR, 1-4). Observations demonstrated consistent glove reuse and poor HCW handwashing. The maintenance of distance (RR 1.09, 95% CI 1.02 to 1.16) and patient handwashing (RR 1.19, 95% CI 1.3 to 1.25) improved to >90%. We found favourable attitudes towards IPC and gaps in practice. Risk perceptions of HCWs and tendencies to ration PPE where chronic supply chain issues normally lead to PPE stock-outs may affect practice. As Sierra Leone's Ebola Recovery Strategy aims to make all facilities IPC compliant, socio-behavioural improvements and a secure supply chain are essential.

  16. How to improve the irradiation conditions for the International Fusion Materials Irradiation Facility

    NASA Astrophysics Data System (ADS)

    Daum, Eric

    2000-12-01

    The accelerator-based intense D-Li neutron source International Fusion Materials Irradiation Facility (IFMIF) provides very suitable irradiation conditions for fusion materials development with the attractive option of accelerated irradiations. Investigations show that a neutron moderator made of tungsten and placed in the IFMIF test cell can further improve the irradiation conditions. The moderator softens the IFMIF neutron spectrum by enhancing the fraction of low energy neutrons. For displacement damage, the ratio of point defects to cascades is more DEMO relevant and for tritium production in Li-based breeding ceramic materials it leads to a preferred production via the 6Li(n,t) 4He channel as it occurs in a DEMO breeding blanket.

  17. Challenges of using quality improvement methods in nursing homes that "need improvement".

    PubMed

    Rantz, Marilyn J; Zwygart-Stauffacher, Mary; Flesner, Marcia; Hicks, Lanis; Mehr, David; Russell, Teresa; Minner, Donna

    2012-10-01

    Qualitatively describe the adoption of strategies and challenges experienced by intervention facilities participating in a study targeted to improve quality of care in nursing homes "in need of improvement". To describe how staff use federal quality indicator/quality measure (QI/QM) scores and reports, quality improvement methods and activities, and how staff supported and sustained the changes recommended by their quality improvement teams. A randomized, two-group, repeated-measures design was used to test a 2-year intervention for improving quality of care and resident outcomes in facilities in "need of improvement". Intervention group (n = 29) received an experimental multilevel intervention designed to help them: (1) use quality-improvement methods, (2) use team and group process for direct-care decision-making, (3) focus on accomplishing the basics of care, and (4) maintain more consistent nursing and administrative leadership committed to communication and active participation of staff in decision-making. A qualitative analysis revealed a subgroup of homes likely to continue quality improvement activities and readiness indicators of homes likely to improve: (1) a leadership team (nursing home administrator, director of nurses) interested in learning how to use their federal QI/QM reports as a foundation for improving resident care and outcomes; (2) one of the leaders to be a "change champion" and make sure that current QI/QM reports are consistently printed and shared monthly with each nursing unit; (3) leaders willing to involve all staff in the facility in educational activities to learn about the QI/QM process and the reports that show how their facility compares with others in the state and nation; (4) leaders willing to plan and continuously educate new staff about the MDS and federal QI/QM reports and how to do quality improvement activities; (5) leaders willing to continuously involve all staff in quality improvement committee and team activities so they "own" the process and are responsible for change. Results of this qualitative analysis can help allocate expert nurse time to facilities that are actually ready to improve. Wide-spread adoption of this intervention is feasible and could be enabled by nursing home medical directors in collaborative practice with advanced practice nurses. Copyright © 2012 American Medical Directors Association, Inc. Published by Elsevier Inc. All rights reserved.

  18. Development of superconductor magnetic suspension and balance prototype facility for studying the feasibility of applying this technique to large scale aerodynamic testing

    NASA Technical Reports Server (NTRS)

    Zapata, R. N.; Humphris, R. R.; Henderson, K. C.

    1975-01-01

    The unique design and operational characteristics of a prototype magnetic suspension and balance facility which utilizes superconductor technology are described and discussed from the point of view of scalability to large sizes. The successful experimental demonstration of the feasibility of this new magnetic suspension concept of the University of Virginia, together with the success of the cryogenic wind-tunnel concept developed at Langley Research Center, appear to have finally opened the way to clean-tunnel, high-Re aerodynamic testing. Results of calculations corresponding to a two-step design extrapolation from the observed performance of the prototype magnetic suspension system to a system compatible with the projected cryogenic transonic research tunnel are presented to give an order-of-magnitude estimate of expected performance characteristics. Research areas where progress should lead to improved design and performance of large facilities are discussed.

  19. Small engine components test facility compressor testing cell at NASA Lewis Research Center

    NASA Technical Reports Server (NTRS)

    Brokopp, Richard A.; Gronski, Robert S.

    1992-01-01

    LeRC has designed and constructed a new test facility. This facility, called the Small Engine Components Facility (SECTF) is used to test gas turbines and compressors at conditions similar to actual engine conditions. The SECTF is comprised of a compressor testing cell and a turbine testing cell. Only the compressor testing cell is described. The capability of the facility, the overall facility design, the instrumentation used in the facility, and the data acquisition system are discussed in detail.

  20. The index of tobacco treatment quality: development of a tool to assess evidence-based treatment in a national sample of drug treatment facilities.

    PubMed

    Cupertino, A Paula; Hunt, Jamie J; Gajewski, Byron J; Jiang, Yu; Marquis, Janet; Friedmann, Peter D; Engelman, Kimberly K; Richter, Kimber P

    2013-03-15

    Quitting smoking improves health and drug use outcomes among people in treatment for substance abuse. The twofold purpose of this study is to describe tobacco treatment provision across a representative sample of U.S. facilities and to use these data to develop the brief Index of Tobacco Treatment Quality (ITTQ). We constructed survey items based on current tobacco treatment guidelines, existing surveys, expert input, and qualitative research. We administered the survey to a stratified sample of 405 facility administrators selected from all 3,800 U.S. adult outpatient facilities listed in the SAMHSA Inventory of Substance Abuse Treatment Services. We constructed the ITTQ with a subset of 7 items that have the strongest clinical evidence for smoking cessation. Most facilities (87.7%) reported that a majority of their clients were asked if they smoke cigarettes. Nearly half of facilities (48.6%) reported that a majority of their smoking clients were advised to quit. Fewer (23.3%) reported that a majority of their smoking clients received tobacco treatment counseling and even fewer facilities (18.3%) reported a majority of their smoking clients were advised to use quit smoking medications. The median facility ITTQ score was 2.57 (on a scale of 1-5) and the ITTQ displayed good internal consistency (Cronbach's alpha = .844). Moreover, the ITTQ had substantial test-retest reliability (.856), and ordinal confirmatory factor analysis found that our one-factor model for ITTQ fit the data very well with a CFI of 0.997 and an RMSEA of 0.042. The ITTQ is a brief and reliable tool for measuring tobacco treatment quality in substance abuse treatment facilities. Given the clear-cut room for improvement in tobacco treatment, the ITTQ could be an important tool for quality improvement by identifying service levels, facilitating goal setting, and measuring change.

  1. The index of tobacco treatment quality: development of a tool to assess evidence-based treatment in a national sample of drug treatment facilities

    PubMed Central

    2013-01-01

    Background Quitting smoking improves health and drug use outcomes among people in treatment for substance abuse. The twofold purpose of this study is to describe tobacco treatment provision across a representative sample of U.S. facilities and to use these data to develop the brief Index of Tobacco Treatment Quality (ITTQ). Methods We constructed survey items based on current tobacco treatment guidelines, existing surveys, expert input, and qualitative research. We administered the survey to a stratified sample of 405 facility administrators selected from all 3,800 U.S. adult outpatient facilities listed in the SAMHSA Inventory of Substance Abuse Treatment Services. We constructed the ITTQ with a subset of 7 items that have the strongest clinical evidence for smoking cessation. Results Most facilities (87.7%) reported that a majority of their clients were asked if they smoke cigarettes. Nearly half of facilities (48.6%) reported that a majority of their smoking clients were advised to quit. Fewer (23.3%) reported that a majority of their smoking clients received tobacco treatment counseling and even fewer facilities (18.3%) reported a majority of their smoking clients were advised to use quit smoking medications. The median facility ITTQ score was 2.57 (on a scale of 1–5) and the ITTQ displayed good internal consistency (Cronbach’s alpha = .844). Moreover, the ITTQ had substantial test-retest reliability (.856), and ordinal confirmatory factor analysis found that our one-factor model for ITTQ fit the data very well with a CFI of 0.997 and an RMSEA of 0.042. Conclusions The ITTQ is a brief and reliable tool for measuring tobacco treatment quality in substance abuse treatment facilities. Given the clear-cut room for improvement in tobacco treatment, the ITTQ could be an important tool for quality improvement by identifying service levels, facilitating goal setting, and measuring change. PMID:23497366

  2. Cervical cancer screening through human papillomavirus testing in community health campaigns versus health facilities in rural western Kenya.

    PubMed

    Huchko, Megan J; Ibrahim, Saduma; Blat, Cinthia; Cohen, Craig R; Smith, Jennifer S; Hiatt, Robert A; Bukusi, Elizabeth

    2018-04-01

    To determine the effectiveness of community health campaigns (CHCs) as a strategy for human papillomavirus (HPV)-based cervical cancer screening in rural western Kenya. Between January and November 2016, a cluster-randomized trial was carried out in 12 communities in western Kenya to investigate high-risk HPV testing offered via self-collection to women aged 25-65 years in CHCs versus government health facilities. Outcome measures were the total number of women accessing cervical cancer screening and the proportion of HPV-positive women accessing treatment. In total, 4944 women underwent HPV-based cervical cancer screening in CHCs (n=2898) or health facilities (n=2046). Screening uptake as a proportion of total eligible women in the population was greater in communities assigned to CHCs (60.0% vs 37.0%, P<0.001). Rates of treatment acquisition were low in both arms (CHCs 39.2%; health facilities 31.5%; P=0.408). Cervical cancer screening using HPV testing of self-collected samples reached a larger proportion of women when offered through periodic CHCs compared with health facilities. The community-based model is a promising strategy for cervical cancer prevention. Lessons learned from this trial can be used to identify ways of maximizing the impact of such strategies through greater community participation and improved linkage to treatment. ClinicalTrials.gov registration: NCT02124252. © 2017 International Federation of Gynecology and Obstetrics.

  3. An automated calibration laboratory for flight research instrumentation: Requirements and a proposed design approach

    NASA Technical Reports Server (NTRS)

    Oneill-Rood, Nora; Glover, Richard D.

    1990-01-01

    NASA's Dryden Flight Research Facility (Ames-Dryden), operates a diverse fleet of research aircraft which are heavily instrumented to provide both real time data for in-flight monitoring and recorded data for postflight analysis. Ames-Dryden's existing automated calibration (AUTOCAL) laboratory is a computerized facility which tests aircraft sensors to certify accuracy for anticipated harsh flight environments. Recently, a major AUTOCAL lab upgrade was initiated; the goal of this modernization is to enhance productivity and improve configuration management for both software and test data. The new system will have multiple testing stations employing distributed processing linked by a local area network to a centralized database. The baseline requirements for the new AUTOCAL lab and the design approach being taken for its mechanization are described.

  4. 78 FR 58449 - Generator Requirements at the Transmission Interface

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-24

    ... Connection Requirements), FAC-003-3 (Transmission Vegetation Management), PRC-004- 2.1a (Analysis and... and Generation Protection System Maintenance and Testing). The modifications improve reliability... Standards FAC-001-1 (Facility Connection Requirements), FAC-003-3 (Transmission Vegetation Management), PRC...

  5. Expanding Hardware-in-the-Loop Formation Navigation and Control with Radio Frequency Crosslink Ranging

    NASA Technical Reports Server (NTRS)

    Mitchell, Jason W.; Barbee, Brent W.; Baldwin, Philip J.; Luquette, Richard J.

    2007-01-01

    The Formation Flying Testbed (FFTB) at the National Aeronautics and Space Administration (NASA) Goddard Space Flight Center (GSFC) provides a hardware-in-the-loop test environment for formation navigation and control. The facility continues to evolve as a modular, hybrid, dynamic simulation facility for end-to-end guidance, navigation, and control (GN&C) design and analysis of formation flying spacecraft. The core capabilities of the FFTB, as a platform for testing critical hardware and software algorithms in-the-loop, are reviewed with a focus on recent improvements. With the most recent improvement, in support of Technology Readiness Level (TRL) 6 testing of the Inter-spacecraft Ranging and Alarm System (IRAS) for the Magnetospheric Multiscale (MMS) mission, the FFTB has significantly expanded its ability to perform realistic simulations that require Radio Frequency (RF) ranging sensors for relative navigation with the Path Emulator for RF Signals (PERFS). The PERFS, currently under development at NASA GSFC, modulates RF signals exchanged between spacecraft. The RF signals are modified to accurately reflect the dynamic environment through which they travel, including the effects of medium, moving platforms, and radiated power.

  6. Beyond signal functions in global obstetric care: Using a clinical cascade to measure emergency obstetric readiness

    PubMed Central

    Dettinger, Julia; Calkins, Kimberly; Kibore, Minnie; Gachuno, Onesmus; Walker, Dilys

    2018-01-01

    Background Globally, the rate of reduction in delivery-associated maternal and perinatal mortality has been slow compared to improvements in post-delivery mortality in children under five. Improving clinical readiness for basic obstetric emergencies is crucial for reducing facility-based maternal deaths. Emergency readiness is commonly assessed using tracers derived from the maternal signal functions model. Objective-method We compare emergency readiness using the signal functions model and a novel clinical cascade. The cascades model readiness as the proportion of facilities with resources to identify the emergency (stage 1), treat it (stage 2) and monitor-modify therapy (stage 3). Data were collected from 44 Kenyan clinics as part of an implementation trial. Findings Although most facilities (77.0%) stock maternal signal function tracer drugs, far fewer have resources to practically identify and treat emergencies. In hypertensive emergencies for example, 38.6% of facilities have resources to identify the emergency (Stage 1 readiness, including sphygmomanometer, stethoscope, urine collection device, protein test). 6.8% have the resources to treat the emergency (Stage 2, consumables (IV Kit, fluids), durable goods (IV pole) and drugs (magnesium sulfate and hydralazine). No facilities could monitor or modify therapy (Stage 3). Across five maternal emergencies, the signal functions overestimate readiness by 54.5%. A consistent, step-wise pattern of readiness loss across signal functions and care stage emerged and was profoundly consistent at 33.0%. Significance Comparing estimates from the maternal signal functions and cascades illustrates four themes. First, signal functions overestimate practical readiness by 55%. Second, the cascade’s intuitive indicators can support cross-sector health system or program planners to more precisely measure and improve emergency care. Third, adding few variables to existing readiness inventories permits step-wise modeling of readiness loss and can inform more precise interventions. Fourth, the novel aggregate readiness loss indicator provides an innovative and intuitive approach for modeling health system emergency readiness. Additional testing in diverse contexts is warranted. PMID:29474397

  7. Summary of Technical Meeting To Compare US/French Approaches for Physical Protection Test Beds

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mack, Thomas Kimball; Martinez, Ruben; Thomas, Gerald

    In September 2015, representatives of the US Department of Energy/National Nuclear Security Administration, including test bed professionals from Sandia National Laboratories, and representatives of the French Alternative Energies and Atomic Energy Commission participated in a one-week workshop to share best practices in design, organization, operations, utilization, improvement, and performance testing of physical protection test beds. The intended workshop outcomes were to (1) share methods of improving respective test bed methodologies and programs and (2) prepare recommendations for standards regarding creating and operating testing facilities for nations new to nuclear operations. At the workshop, the French and American subject matter expertsmore » compared best practices as developed at their respective test bed sites; discussed access delay test bed considerations; and presented the limitations/ constraints of physical protection test beds.« less

  8. Impact of Advanced Practice Registered Nurses on Quality Measures: The Missouri Quality Initiative Experience.

    PubMed

    Rantz, Marilyn J; Popejoy, Lori; Vogelsmeier, Amy; Galambos, Colleen; Alexander, Greg; Flesner, Marcia; Murray, Cathy; Crecelius, Charles; Ge, Bin; Petroski, Gregory

    2018-06-01

    The purpose of this article is to review the impact of advanced practice registered nurses (APRNs) on the quality measure (QM) scores of the 16 participating nursing homes of the Missouri Quality Initiative (MOQI) intervention. The MOQI was one of 7 program sites in the US, with specific interventions unique to each site tested for the Centers for Medicaid and Medicare Services Innovations Center. While the goals of the MOQI for long-stay nursing home residents did not specifically include improvement of the QM scores, it was anticipated that improvement most likely would occur. Primary goals of the MOQI were to reduce the frequency of avoidable hospital admissions and readmissions; improve resident health outcomes; improve the process of transitioning between inpatient hospitals and nursing facilities; and reduce overall healthcare spending without restricting access to care or choice of providers. A 2-group comparison analysis was conducted using statewide QMs; a matched comparison group was selected from facilities in the same counties as the intervention homes, similar baseline QM scores, similar size and ownership. MOQI nursing homes each had an APRN embedded full-time to improve care and help the facility achieve MOQI goals. Part of their clinical work with residents and staff was to focus on quality improvement strategies with potential to influence healthcare outcomes. Trajectories of QM scores for the MOQI intervention nursing homes and matched comparison group homes were tested with nonparametric tests to examine for change in the desired direction between the 2 groups from baseline to 36 months. A composite QM score for each facility was constructed, and baseline to 36-month average change scores were examined using nonparametric tests. Then, adjusting for baseline, a repeated measures analysis using analysis of covariance as conducted. Composite QM scores of the APRN intervention group were significantly better (P = .025) than the comparison group. The repeated measures analysis identified statistically significant group by time interaction (P = .012). Then group comparisons were made at each of the 6-month intervals and statistically significant differences were found at 24 months (P = .042) and 36 months (P = .002), and nearly significant at 30 months (P = .11). APRNs working full time in nursing homes can positively influence quality of care, and their impact can be measured on improving QMs. As more emphasis is placed on quality and outcomes for nursing home services, providers need to find successful strategies to improve their QMs. Results of these analyses reveal the positive impact on QM outcomes for the majority of the MOQI nursing homes, indicating budgeting for APRN services can be a successful strategy. Copyright © 2017 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  9. An Examination of Care Practices of Pregnant Women Incarcerated in Jail Facilities in the United States.

    PubMed

    Kelsey, C M; Medel, Nickole; Mullins, Carson; Dallaire, Danielle; Forestell, Catherine

    2017-06-01

    The number of incarcerated women in the United States has been steadily increasing over the last 30 years. An estimated 6-10% of these women are pregnant at intake. Previous studies on the health needs and care of pregnant incarcerated women have focused mainly on prison settings. Therefore, we examined the pregnancy-related accommodations and health care provided for regional jail populations. The present study is a quantitative survey (administered through phone or email to employees of predominately jail medical facilities) of common practices and policies employed across 53 jail facilities in the United States as a function of geographic region (North vs. South; West vs. Central vs. East). We examined provision of pregnancy screening, special diets, and drug rehabilitation and prohibition of shackling. Strikingly, across all aspects of the care of pregnant incarcerated women there are areas to be improved upon. Notably, only 37.7% of facilities pregnancy test all women upon entry, 45.7% put opioid addicted women through withdrawal protocol, and 56.7% of facilities use restraints on women hours after having a baby. In this first study to examine practices in regional jails nationwide, we found evidence that standards of care guidelines to improve health and well-being of pregnant incarcerated women, set by agencies such as American College of Obstetricians and Gynecologists, are not being followed in many facilities. Because not following these guidelines could pose major health risks to the mother and developing fetus, better policies, better enforcement of policies, and better common practices are needed to improve the health and welfare of pregnant incarcerated women.

  10. Experimental investigation of nozzle/plume aerodynamics at hypersonic speeds

    NASA Technical Reports Server (NTRS)

    Bogdanoff, David W.; Cambier, Jean-Luc; Papadopoulos, Perikles

    1994-01-01

    Much of the work involved the Ames 16-Inch Shock Tunnel facility. The facility was reactivated and upgraded, a data acquisition system was configured and upgraded several times, several facility calibrations were performed and test entries with a wedge model with hydrogen injection and a full scramjet combustor model, with hydrogen injection, were performed. Extensive CFD modeling of the flow in the facility was done. This includes modeling of the unsteady flow in the driver and driven tubes and steady flow modeling of the nozzle flow. Other modeling efforts include simulations of non-equilibrium flows and turbulence, plasmas, light gas guns and the use of non-ideal gas equations of state. New experimental techniques to improve the performance of gas guns, shock tubes and tunnels and scramjet combustors were conceived and studied computationally. Ways to improve scramjet engine performance using steady and pulsed detonation waves were also studied computationally. A number of studies were performed on the operation of the ram accelerator, including investigations of in-tube gasdynamic heating and the use of high explosives to raise the velocity capability of the device.

  11. Microbiological monitoring of guinea pigs reared conventionally at two breeding facilities in Korea.

    PubMed

    Park, Jong-Hwan; Seok, Seung-Hyeok; Baek, Min-Won; Lee, Hui-Young; Kim, Dong-Jae; Cho, Jung-Sik; Kim, Chuel-Kyu; Hwang, Dae-Youn; Park, Jae-Hak

    2006-10-01

    In this study, microbiological monitoring of guinea pigs reared conventionally in two facilities was performed twice in 2004, with a three-month-interval between surveys. This study was based on the recommendations of the FELASA Working Group, with some modifications. In serological tests in the first survey, some animals from facility A showed positive results for Encephalitozoon cuniculi, Sendai virus, pneumonia virus of mice (PVM), and Reovirus-3 (Reo-3); facility B showed a positive result only for E. cuniculi. The results of the second survey were similar to the first, except for the presence of Sendai virus; all animals from the two facilities were Sendai virus-negative in the second experiment. No pathogenic bacteria were cultured in the organs of any of the animals in the first survey. However, in the second survey, Bordetella bronchiseptica was cultured from the lung tissue of two 10-week-old animals from facility A. Chlamydial infection was examined by the Macchiavello method, but no animal showed positive results. Tests using fecal flotation or the KOH wet mount method showed no infection of endoparasites, protozoa, ectoparasites, or dermatophytes in any animal in both surveys. However, in the histopathological examination, an infection of protozoa-like organisms was observed in the cecum of some animals from facility A. The present study revealed that microbiological contamination was present in guinea pigs reared conventionally in two facilities in Korea, suggesting that there is a need to improve environmental conditions in order to eradicate microbial contamination.

  12. Space technology test facilities at the NASA Ames Research Center

    NASA Technical Reports Server (NTRS)

    Gross, Anthony R.; Rodrigues, Annette T.

    1990-01-01

    The major space research and technology test facilities at the NASA Ames Research Center are divided into five categories: General Purpose, Life Support, Computer-Based Simulation, High Energy, and the Space Exploraton Test Facilities. The paper discusses selected facilities within each of the five categories and discusses some of the major programs in which these facilities have been involved. Special attention is given to the 20-G Man-Rated Centrifuge, the Human Research Facility, the Plant Crop Growth Facility, the Numerical Aerodynamic Simulation Facility, the Arc-Jet Complex and Hypersonic Test Facility, the Infrared Detector and Cryogenic Test Facility, and the Mars Wind Tunnel. Each facility is described along with its objectives, test parameter ranges, and major current programs and applications.

  13. 40 CFR 160.43 - Test system care facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... testing facility shall have a number of animal rooms or other test system areas separate from those... GOOD LABORATORY PRACTICE STANDARDS Facilities § 160.43 Test system care facilities. (a) A testing facility shall have a sufficient number of animal rooms or other test system areas, as needed, to ensure...

  14. 40 CFR 160.43 - Test system care facilities.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... testing facility shall have a number of animal rooms or other test system areas separate from those... GOOD LABORATORY PRACTICE STANDARDS Facilities § 160.43 Test system care facilities. (a) A testing facility shall have a sufficient number of animal rooms or other test system areas, as needed, to ensure...

  15. Break modeling for RELAP5 analyses of ISP-27 Bethsy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Petelin, S.; Gortnar, O.; Mavko, B.

    This paper presents pre- and posttest analyses of International Standard Problem (ISP) 27 on the Bethsy facility and separate RELAP5 break model tests considering the measured boundary condition at break inlet. This contribution also demonstrates modifications which have assured the significant improvement of model response in posttest simulations. Calculations were performed using the RELAP5/MOD2/36.05 and RELAP5/MOD3.5M5 codes on the MicroVAX, SUN, and CONVEX computers. Bethsy is an integral test facility that simulates a typical 900-MW (electric) Framatome pressurized water reactor. The ISP-27 scenario involves a 2-in. cold-leg break without HPSI and with delayed operator procedures for secondary system depressurization.

  16. Force Measurement Improvements to the National Transonic Facility Sidewall Model Support System

    NASA Technical Reports Server (NTRS)

    Goodliff, Scott L.; Balakrishna, Sundareswara; Butler, David; Cagle, C. Mark; Chan, David; Jones, Gregory S.; Milholen, William E., II

    2016-01-01

    The National Transonic Facility is a transonic pressurized cryogenic facility. The development of the high Reynolds number semi-span capability has advanced over the years to include transonic active flow control and powered testing using the sidewall model support system. While this system can be used in total temperatures down to -250Â F for conventional unpowered configurations, it is limited to temperatures above -60Â F when used with powered models that require the use of the high-pressure air delivery system. Thermal instabilities and non-repeatable mechanical arrangements revealed several data quality shortfalls by the force and moment measurement system. Recent modifications to the balance cavity recirculation system have improved the temperature stability of the balance and metric model-to-balance hardware. Changes to the mechanical assembly of the high-pressure air delivery system, particularly hardware that interfaces directly with the model and balance, have improved the repeatability of the force and moment measurement system. Drag comparisons with the high-pressure air system removed will also be presented in this paper.

  17. Identification of Ways to Improve Military Construction for Energy-Efficient Facilities.

    DTIC Science & Technology

    1987-12-01

    inservice . Thus, it is necessary to control techniques, materials, and equip- S ment as part of the Military Construction, Army (MCA) process to ensure...Moreover, USACE often lacks proper test equipment and trained personnel at many construction sites. The 0 result is that acceptance testing often is...on a few diagnostic procedures. USACE quality assurance inspectors would be trained to do the tests. .-. Objectives 0 The overall objective of this

  18. The 11th Space Simulation Conference

    NASA Technical Reports Server (NTRS)

    Bond, A. C. (Editor)

    1980-01-01

    Subject areas range from specialized issues dealing with the space and entry environments to the environmental testing of systems and complete spacecraft of present-day vintage. Various papers consider: the test and development of several key systems of the orbiter vehicle; integrated tests of complete satellites; new and unique test facilities developed to meet the demanding requirements of high fidelity simulation of test environments; and contamination species, including the instrumentation for detection and measurement of such. Special topics include improved thermal protection methodologies and approaches, sophisticated sensor developments, and other related testing and development areas.

  19. Impact of a systems engineering intervention on PMTCT service delivery in Côte d’Ivoire, Kenya, Mozambique: a cluster randomized trial

    PubMed Central

    Rustagi, Alison Silvis; Gimbel, Sarah; Nduati, Ruth; de Fatima Cuembelo, Maria; Wasserheit, Judith N.; Farquhar, Carey; Gloyd, Stephen; Sherr, Kenneth

    2016-01-01

    BACKGROUND Efficacious interventions to prevent mother-to-child HIV transmission (PMTCT) have not translated well into effective programs. Prior studies of systems engineering applications to PMTCT lacked comparison groups or randomization. METHODS Thirty-six health facilities in Côte d’Ivoire, Kenya, and Mozambique were randomized to usual care or a systems engineering intervention, stratified by country and volume. The intervention guided facility staff to iteratively identify and then rectify barriers to PMTCT implementation. Registry data quantified coverage of HIV testing during first antenatal care visit, antiretrovirals (ARVs) for HIV-positive pregnant women, and screening HIV-exposed infants (HEI) for HIV by 6–8 weeks. We compared the change between baseline (January 2013–January 2014) and post-intervention (January–March 2015) periods using t-tests. All analyses were intent-to-treat. RESULTS ARV coverage increased 3-fold (+13.3 percentage points [95% CI: 0.5, 26.0] in intervention vs. +4.1 [−12.6, 20.7] in control facilities) and HEI screening increased 17-fold (+11.6 [−2.6, 25.7] in intervention vs. +0.7 [−12.9, 14.4] in control facilities). In pre-specified sub-group analyses, ARV coverage increased significantly in Kenya (+20.9 [−3.1, 44.9] in intervention vs. −21.2 [−52.7, 10.4] in controls; p=0.02). HEI screening increased significantly in Mozambique (+23.1 [10.3, 35.8] in intervention vs. +3.7 [−13.1, 20.6] in controls; p=0.04). HIV testing did not differ significantly between arms. CONCLUSIONS In this first randomized trial of systems engineering to improve PMTCT, we saw substantially larger improvements in ARV coverage and HEI screening in intervention facilities compared to controls, which were significant in pre-specified sub-groups. Systems engineering could strengthen PMTCT service delivery and protect infants from HIV. PMID:27082507

  20. Implementation and Operational Research: Impact of a Systems Engineering Intervention on PMTCT Service Delivery in Côte d'Ivoire, Kenya, Mozambique: A Cluster Randomized Trial.

    PubMed

    Rustagi, Alison Silvis; Gimbel, Sarah; Nduati, Ruth; Cuembelo, Maria de Fatima; Wasserheit, Judith N; Farquhar, Carey; Gloyd, Stephen; Sherr, Kenneth

    2016-07-01

    Efficacious interventions to prevent mother-to-child HIV transmission (PMTCT) have not translated well into effective programs. Previous studies of systems engineering applications to PMTCT lacked comparison groups or randomization. Thirty-six health facilities in Côte d'Ivoire, Kenya, and Mozambique were randomized to usual care or a systems engineering intervention, stratified by country and volume. The intervention guided facility staff to iteratively identify and then rectify barriers to PMTCT implementation. Registry data quantified coverage of HIV testing during first antenatal care visit, antiretrovirals (ARVs) for HIV-positive pregnant women, and screening HIV-exposed infants (HEI) for HIV by 6-8 weeks. We compared the change between baseline (January 2013-January 2014) and postintervention (January 2015-March 2015) periods using t-tests. All analyses were intent-to-treat. ARV coverage increased 3-fold [+13.3% points (95% CI: 0.5 to 26.0) in intervention vs. +4.1 (-12.6 to 20.7) in control facilities] and HEI screening increased 17-fold [+11.6 (-2.6 to 25.7) in intervention vs. +0.7 (-12.9 to 14.4) in control facilities]. In prespecified subgroup analyses, ARV coverage increased significantly in Kenya [+20.9 (-3.1 to 44.9) in intervention vs. -21.2 (-52.7 to 10.4) in controls; P = 0.02]. HEI screening increased significantly in Mozambique [+23.1 (10.3 to 35.8) in intervention vs. +3.7 (-13.1 to 20.6) in controls; P = 0.04]. HIV testing did not differ significantly between arms. In this first randomized trial of systems engineering to improve PMTCT, we saw substantially larger improvements in ARV coverage and HEI screening in intervention facilities compared with controls, which were significant in prespecified subgroups. Systems engineering could strengthen PMTCT service delivery and protect infants from HIV.

  1. Inputs to quality: supervision, management, and community involvement in health facilities in Egypt in 2004.

    PubMed

    Cherlin, Emily J; Allam, Adel A; Linnander, Erika L; Wong, Rex; El-Toukhy, Essam; Sipsma, Heather; Krumholz, Harlan M; Curry, Leslie A; Bradley, Elizabeth H

    2011-10-20

    As low- and middle-income countries experience economic development, ensuring quality of health care delivery is a central component of health reform. Nevertheless, health reforms in low- and middle-income countries have focused more on access to services rather than the quality of these services, and reporting on quality has been limited. In the present study, we sought to examine the prevalence and regional variation in key management practices in Egyptian health facilities within three domains: supervision of the facility from the Ministry of Health and Population (MOHP), managerial processes, and patient and community involvement in care. We conducted a cross-sectional analysis of data from 559 facilities surveyed with the Egyptian Service Provision Assessment (ESPA) survey in 2004, the most recent such survey in Egypt. We registered on the Measure Demographic and Health Survey (DHS) website http://legacy.measuredhs.com/login.cfm to gain access to the survey data. From the ESPA sampled 559 MOHP facilities, we excluded a total of 79 facilities because they did not offer facility-based 24-hour care or have at least one physician working in the facility, resulting in a final sample of 480 facilities. The final sample included 76 general service hospitals, 307 rural health units, and 97 maternal and child health and urban health units (MCH/urban units). We used standard frequency analyses to describe facility characteristics and tested the statistical significance of regional differences using chi-square statistics. Nearly all facilities reported having external supervision within the 6 months preceding the interview. In contrast, key facility-level managerial processes, such as having routine and documented management meetings and applying quality assurance approaches, were uncommon. Involvement of communities and patients was also reported in a minority of facilities. Hospitals and health units located in Urban Egypt compared with more rural parts of Egypt were significantly more likely to have management committees that met at least monthly, to keep official records of the meetings, and to have an approach for reviewing quality assurance activities. Although the data precede the recent reform efforts of the MOHP, they provide a baseline against which future progress can be measured. Targeted efforts to improve facility-level management are critical to supporting quality improvement initiatives directed at improving the quality of health care throughout the country.

  2. New recreational facilities for the young and the old in Los Angeles: policy and programming implications.

    PubMed

    Cohen, Deborah A; Sehgal, Amber; Williamson, Stephanie; Marsh, Terry; Golinelli, Daniela; McKenzie, Thomas L

    2009-01-01

    It is assumed that higher quality recreation facilities promote physical activity and serve communities better. We tested this assumption by comparing changes in the use of an expanded and renovated skate park (a facility for skateboarding) and a modernized senior citizen's center to two similar facilities that were not refurbished. The skate park was nearly tripled in size, and the senior center was remodeled and received new exercise equipment, a courtyard garden, and modern architectural features. We assessed use of these facilities through direct observation and surveyed both facility users and residents living within 2 miles of each facility. We found that making improvements to facilities alone will not always guarantee increased use. Although there was a 510% increase in use of the expanded skate park compared to a 77% increase in the comparison skate park, the senior center had substantially fewer users and provided fewer hours of exercise classes and other programmed activities after the facility was renovated. The implication of our study is that use results from a complex equation that includes not only higher quality recreation facilities but also progamming, staffing, fees, hours of operation, marketing, outreach, and perhaps a host of other human factors.

  3. Measurement Requirements for Improved Modeling of Arcjet Facility Flows

    NASA Technical Reports Server (NTRS)

    Fletcher, Douglas G.

    2000-01-01

    Current efforts to develop new reusable launch vehicles and to pursue low-cost robotic planetary missions have led to a renewed interest in understanding arc-jet flows. Part of this renewed interest is concerned with improving the understanding of arc-jet test results and the potential use of available computational-fluid- dynamic (CFD) codes to aid in this effort. These CFD codes have been extensively developed and tested for application to nonequilibrium, hypersonic flow modeling. It is envisioned, perhaps naively, that the application of these CFD codes to the simulation of arc-jet flows would serve two purposes: first. the codes would help to characterize the nonequilibrium nature of the arc-jet flows; and second. arc-jet experiments could potentially be used to validate the flow models. These two objectives are, to some extent, mutually exclusive. However, the purpose of the present discussion is to address what role CFD codes can play in the current arc-jet flow characterization effort, and whether or not the simulation of arc-jet facility tests can be used to eva1uate some of the modeling that is used to formu1ate these codes. This presentation is organized into several sections. In the introductory section, the development of large-scale, constricted-arc test facilities within NASA is reviewed, and the current state of flow diagnostics using conventional instrumentation is summarized. The motivation for using CFD to simulate arc-jet flows is addressed in the next section, and the basic requirements for CFD models that would be used for these simulations are briefly discussed. This section is followed by a more detailed description of experimental measurements that are needed to initiate credible simulations and to evaluate their fidelity in the different flow regions of an arc-jet facility. Observations from a recent combined computational and experiment.al investigation of shock-layer flows in a large-scale arc-jet facility are then used to illustrate the current state of development of diagnostic instrumentation, CFD simulations, and general knowledge in the field of arc-jet characterization. Finally, the main points are summarized and recommendations for future efforts are given.

  4. 10 CFR 26.123 - Testing facility capabilities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Testing facility capabilities. 26.123 Section 26.123 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.123 Testing facility capabilities. Each licensee testing facility shall have the capability, at the same...

  5. 10 CFR 26.123 - Testing facility capabilities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Testing facility capabilities. 26.123 Section 26.123 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.123 Testing facility capabilities. Each licensee testing facility shall have the capability, at the same...

  6. 10 CFR 26.123 - Testing facility capabilities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 1 2013-01-01 2013-01-01 false Testing facility capabilities. 26.123 Section 26.123 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.123 Testing facility capabilities. Each licensee testing facility shall have the capability, at the same...

  7. 10 CFR 26.123 - Testing facility capabilities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 1 2011-01-01 2011-01-01 false Testing facility capabilities. 26.123 Section 26.123 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.123 Testing facility capabilities. Each licensee testing facility shall have the capability, at the same...

  8. 10 CFR 26.123 - Testing facility capabilities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Testing facility capabilities. 26.123 Section 26.123 Energy NUCLEAR REGULATORY COMMISSION FITNESS FOR DUTY PROGRAMS Licensee Testing Facilities § 26.123 Testing facility capabilities. Each licensee testing facility shall have the capability, at the same...

  9. Initial Testing of the Mark-0 X-Band RF Gun at SLAC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vlieks, Arnold; Adolphsen, C.; Dolgashev, V.

    A new X-band RF gun (Mark-0) has been assembled, tuned and was tested in the ASTA facility at SLAC. This gun has been improved from an earlier gun used in Compton-scattering experiments at SLAC by the introduction of a racetrack dual-input coupler to reduce quadrupole fields. Waveguide-to-coupler irises were also redesigned to reduce surface magnetic fields and therefore peak pulse surface heating. Tests of this photocathode gun will allow us to gain early operational experience for beam tests of a new gun with further improvements (Mark-1) being prepared for SLAC's X-Band Test Area (XTA) program and the LLNL MEGa-ray program.more » Results of current testing up to {approx} 200 MV/m peak surface Electric fields are presented.« less

  10. Improving Student Safety.

    ERIC Educational Resources Information Center

    Dorn, Michael; Trump, Kenneth S.; Nichols, R. Leslie

    2001-01-01

    Presents the latest information on how schools can keep their students safe. Safety oriented actions discussed cover incident reporting and tracking, tactical site surveys, school safety and emergency operations planning, staff development efforts, and facility design. Explains the need to review and test specific prevention concepts and emergency…

  11. A brief, standardized tool for measuring HIV-related stigma among health facility staff: results of field testing in China, Dominica, Egypt, Kenya, Puerto Rico and St. Christopher & Nevis.

    PubMed

    Nyblade, Laura; Jain, Aparna; Benkirane, Manal; Li, Li; Lohiniva, Anna-Leena; McLean, Roger; Turan, Janet M; Varas-Díaz, Nelson; Cintrón-Bou, Francheska; Guan, Jihui; Kwena, Zachary; Thomas, Wendell

    2013-11-13

    Within healthcare settings, HIV-related stigma is a recognized barrier to access of HIV prevention and treatment services and yet, few efforts have been made to scale-up stigma reduction programs in service delivery. This is in part due to the lack of a brief, simple, standardized tool for measuring stigma among all levels of health facility staff that works across diverse HIV prevalence, language and healthcare settings. In response, an international consortium led by the Health Policy Project, has developed and field tested a stigma measurement tool for use with health facility staff. Experts participated in a content-development workshop to review an item pool of existing measures, identify gaps and prioritize questions. The resulting questionnaire was field tested in six diverse sites (China, Dominica, Egypt, Kenya, Puerto Rico and St. Christopher & Nevis). Respondents included clinical and non-clinical staff. Questionnaires were self- or interviewer-administered. Analysis of item performance across sites examined both psychometric properties and contextual issues. The key outcome of the process was a substantially reduced questionnaire. Eighteen core questions measure three programmatically actionable drivers of stigma within health facilities (worry about HIV transmission, attitudes towards people living with HIV (PLHIV), and health facility environment, including policies), and enacted stigma. The questionnaire also includes one short scale for attitudes towards PLHIV (5-item scale, α=0.78). Stigma-reduction programmes in healthcare facilities are urgently needed to improve the quality of care provided, uphold the human right to healthcare, increase access to health services, and maximize investments in HIV prevention and treatment. This brief, standardized tool will facilitate inclusion of stigma measurement in research studies and in routine facility data collection, allowing for the monitoring of stigma within healthcare facilities and evaluation of stigma-reduction programmes. There is potential for wide use of the tool either as a stand-alone survey or integrated within other studies of health facility staff.

  12. THE CONCEPTUAL DESIGN ASSESSMENT FOR THE CO-FIRING OF BIO-REFINERY SUPPLIED LIGNIN PROJECT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ted Berglund; Jeffrey T. Ranney; Carol L. Babb

    2001-07-01

    The major aspects of this project are proceeding toward completion. Prior to this quarter, design criteria, tentative site selection, facility layout, and preliminary facility cost estimates were completed and issued. Processing of bio-solids was completed, providing material for the pilot operations. Pilot facility design, equipment selection, and modification were completed during the fourth quarter of 2000. Initial pilot facility shakedown was completed during the fourth quarter. After some unavoidable delays, a suitable representative supply of MSW feed material was procured. During this first quarter of 2001, shredding of the feed material and final feed conditioning were completed. Pilot facility hydrolysismore » production was completed to produce lignin for co-fire testing. During this quarter, TVA completed the washing and dewatering of the lignin material produced from the MSW hydrolysis. Seven drums of lignin material were washed to recover the acid and sugar from the lignin and provide an improved fuel for steam generation. Samples of both the lignin and bio-solids fuel materials for co-fire testing were sent to the co-fire facility (EERC) for evaluation. After sample evaluation, EERC approved sending the material and all of the necessary fuel for testing was shipped to EERC. EERC has requested and will receive coal typical of the fuel to the TVA-Colbert boilers. This material will be used at EERC as baseline material and for mixing with the bio-fuel for combustion testing. EERC combustion testing of the bio based fuels is scheduled to begin in August of 2001. The TVA-Colbert facility has neared completion of the task to evaluate the co-location of the Masada facility on the operation of the power generation facility. The TVA-Colbert fossil plant is fully capable of providing a reliable steam supply. The preferred steam supply connection points and steam pipeline routing have been identified. The environmental review of the pipeline routing has been completed and no major impacts have been identified. Detailed assessment of steam export impacts on the Colbert boiler system have been completed and a cost estimate for steam supply system was completed. The cost estimate and the output and heat rate impacts will be used to determine a preliminary price for the exported steam. The preliminary steam price will be determined in the next quarter.« less

  13. Evaluation of a laboratory quality assurance pilot programme for malaria diagnostics in low-transmission areas of Kenya, 2013.

    PubMed

    Wanja, Elizabeth; Achilla, Rachel; Obare, Peter; Adeny, Rose; Moseti, Caroline; Otieno, Victor; Morang'a, Collins; Murigi, Ephantus; Nyamuni, John; Monthei, Derek R; Ogutu, Bernhards; Buff, Ann M

    2017-05-25

    One objective of the Kenya National Malaria Strategy 2009-2017 is scaling access to prompt diagnosis and effective treatment. In 2013, a quality assurance (QA) pilot was implemented to improve accuracy of malaria diagnostics at selected health facilities in low-transmission counties of Kenya. Trends in malaria diagnostic and QA indicator performance during the pilot are described. From June to December 2013, 28 QA officers provided on-the-job training and mentoring for malaria microscopy, malaria rapid diagnostic tests and laboratory QA/quality control (QC) practices over four 1-day visits at 83 health facilities. QA officers observed and recorded laboratory conditions and practices and cross-checked blood slides for malaria parasite presence, and a portion of cross-checked slides were confirmed by reference laboratories. Eighty (96%) facilities completed the pilot. Among 315 personnel at pilot initiation, 13% (n = 40) reported malaria diagnostics training within the previous 12 months. Slide positivity ranged from 3 to 7%. Compared to the reference laboratory, microscopy sensitivity ranged from 53 to 96% and positive predictive value from 39 to 53% for facility staff and from 60 to 96% and 52 to 80%, respectively, for QA officers. Compared to reference, specificity ranged from 88 to 98% and negative predictive value from 98 to 99% for health-facility personnel and from 93 to 99% and 99%, respectively, for QA officers. The kappa value ranged from 0.48-0.66 for facility staff and 0.57-0.84 for QA officers compared to reference. The only significant test performance improvement observed for facility staff was for specificity from 88% (95% CI 85-90%) to 98% (95% CI 97-99%). QA/QC practices, including use of positive-control slides, internal and external slide cross-checking and recording of QA/QC activities, all increased significantly across the pilot (p < 0.001). Reference material availability also increased significantly; availability of six microscopy job aids and seven microscopy standard operating procedures increased by a mean of 32 percentage points (p < 0.001) and 38 percentage points (p < 0.001), respectively. Significant gains were observed in malaria QA/QC practices over the pilot. However, these advances did not translate into improved accuracy of malaria diagnostic performance perhaps because of the limited duration of the QA pilot implementation.

  14. Barriers to providing palliative care in long-term care facilities

    PubMed Central

    Brazil, Kevin; Bédard, Michel; Krueger, Paul; Taniguchi, Alan; Kelley, Mary Lou; McAiney, Carrie; Justice, Christopher

    2006-01-01

    OBJECTIVE To assess challenges in providing palliative care in long-term care (LTC) facilities from the perspective of medical directors. DESIGN Cross-sectional mailed survey. A questionnaire was developed, reviewed, pilot-tested, and sent to 450 medical directors representing 531 LTC facilities. Responses were rated on 2 different 5-point scales. Descriptive analyses were conducted on all responses. SETTING All licensed LTC facilities in Ontario with designated medical directors. PARTICIPANTS Medical directors in the facilities. MAIN OUTCOME MEASURES Demographic and practice characteristics of physicians and facilities, importance of potential barriers to providing palliative care, strategies that could be helpful in providing palliative care, and the kind of training in palliative care respondents had received. RESULTS Two hundred seventy-five medical directors (61%) representing 302 LTC facilities (57%) responded to the survey. Potential barriers to providing palliative care were clustered into 3 groups: facility staff’s capacity to provide palliative care, education and support, and the need for external resources. Two thirds of respondents (67.1%) reported that inadequate staffing in their facilities was an important barrier to providing palliative care. Other barriers included inadequate financial reimbursement from the Ontario Health Insurance Program (58.5%), the heavy time commitment required (47.3%), and the lack of equipment in facilities (42.5%). No statistically significant relationship was found between geographic location or profit status of facilities and barriers to providing palliative care. Strategies respondents would use to improve provision of palliative care included continuing medical education (80.0%), protocols for assessing and monitoring pain (77.7%), finding ways to increase financial reimbursement for managing palliative care residents (72.1%), providing educational material for facility staff (70.7%), and providing practice guidelines related to assessing and managing palliative care patients (67.8%). CONCLUSION Medical directors in our study reported that their LTC facilities were inadequately staffed and lacked equipment. The study also highlighted the specialized role of medical directors, who identified continuing medical education as a key strategy for improving provision of palliative care. PMID:17327890

  15. Barriers to providing palliative care in long-term care facilities.

    PubMed

    Brazil, Kevin; Bédard, Michel; Krueger, Paul; Taniguchi, Alan; Kelley, Mary Lou; McAiney, Carrie; Justice, Christopher

    2006-04-01

    To assess challenges in providing palliative care in long-term care (LTC) facilities from the perspective of medical directors. Cross-sectional mailed survey. A questionnaire was developed, reviewed, pilot-tested, and sent to 450 medical directors representing 531 LTC facilities. Responses were rated on 2 different 5-point scales. Descriptive analyses were conducted on all responses. All licensed LTC facilities in Ontario with designated medical directors. Medical directors in the facilities. Demographic and practice characteristics of physicians and facilities, importance of potential barriers to providing palliative care, strategies that could be helpful in providing palliative care, and the kind of training in palliative care respondents had received. Two hundred seventy-five medical directors (61%) representing 302 LTC facilities (57%) responded to the survey. Potential barriers to providing palliative care were clustered into 3 groups: facility staff's capacity to provide palliative care, education and support, and the need for external resources. Two thirds of respondents (67.1%) reported that inadequate staffing in their facilities was an important barrier to providing palliative care. Other barriers included inadequate financial reimbursement from the Ontario Health Insurance Program (58.5%), the heavy time commitment required (47.3%), and the lack of equipment in facilities (42.5%). No statistically significant relationship was found between geographic location or profit status of facilities and barriers to providing palliative care. Strategies respondents would use to improve provision of palliative care included continuing medical education (80.0%), protocols for assessing and monitoring pain (77.7%), finding ways to increase financial reimbursement for managing palliative care residents (72.1%), providing educational material for facility staff (70.7%), and providing practice guidelines related to assessing and managing palliative care patients (67.8%). Medical directors in our study reported that their LTC facilities were inadequately staffed and lacked equipment. The study also highlighted the specialized role of medical directors, who identified continuing medical education as a key strategy for improving provision of palliative care.

  16. Gasification Product Improvement Facility (GPIF). Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-09-01

    The gasifier selected for development under this contract is an innovative and patented hybrid technology which combines the best features of both fixed-bed and fluidized-bed types. PyGas{trademark}, meaning Pyrolysis Gasification, is well suited for integration into advanced power cycles such as IGCC. It is also well matched to hot gas clean-up technologies currently in development. Unlike other gasification technologies, PyGas can be designed into both large and small scale systems. It is expected that partial repowering with PyGas could be done at a cost of electricity of only 2.78 cents/kWh, more economical than natural gas repowering. It is extremely unfortunatemore » that Government funding for such a noble cause is becoming reduced to the point where current contracts must be canceled. The Gasification Product Improvement Facility (GPIF) project was initiated to provide a test facility to support early commercialization of advanced fixed-bed coal gasification technology at a cost approaching $1,000 per kilowatt for electric power generation applications. The project was to include an innovative, advanced, air-blown, pressurized, fixed-bed, dry-bottom gasifier and a follow-on hot metal oxide gas desulfurization sub-system. To help defray the cost of testing materials, the facility was to be located at a nearby utility coal fired generating site. The patented PyGas{trademark} technology was selected via a competitive bidding process as the candidate which best fit overall DOE objectives. The paper describes the accomplishments to date.« less

  17. Process evaluation of the RaDIANT community study: a dialysis facility-level intervention to increase referral for kidney transplantation.

    PubMed

    Hamoda, Reem E; Gander, Jennifer C; McPherson, Laura J; Arriola, Kimberly J; Cobb, Loren; Pastan, Stephen O; Plantinga, Laura; Browne, Teri; Hartmann, Erica; Mulloy, Laura; Zayas, Carlos; Krisher, Jenna; Patzer, Rachel E

    2018-01-15

    The Reducing Disparities in Access to kidNey Transplantation Community Study (RaDIANT) was an End-Stage Renal Disease (ESRD) Network 6-developed, dialysis facility-level randomized trial testing the effectiveness of a 1-year multicomponent education and quality improvement intervention in increasing referral for kidney transplant evaluation among selected Georgia dialysis facilities. To assess implementation of the RaDIANT intervention, we conducted a process evaluation at the conclusion of the intervention period (January-December 2014). We administered a 20-item survey to the staff involved with transplant education in 67 dialysis facilities randomized to participate in intervention activities. Survey items assessed facility participation in the intervention (fidelity and reach), helpfulness and willingness to continue intervention activities (sustainability), suggestions for improving intervention components (sustainability), and factors that may have influenced participation and study outcomes (context). We defined high fidelity to the intervention as completing 11 or more activities, and high participation in an activity as having at least 75% participation across intervention facilities. Staff from 65 of the 67 dialysis facilities completed the questionnaire, and more than half (50.8%) reported high adherence (fidelity) to RaDIANT intervention requirements. Nearly two-thirds (63.1%) of facilities reported that RaDIANT intervention activities were helpful or very helpful, with 90.8% of facilities willing to continue at least one intervention component beyond the study period. Intervention components with high participation emphasized staff and patient-level education, including in-service staff orientations, patient and family education programs, and patient educational materials. Suggested improvements for intervention activities emphasized addressing financial barriers to transplantation, with financial education materials perceived as most helpful among RaDIANT educational materials. Variation in facility-level fidelity of the RADIANT intervention did not significantly influence the mean difference in proportion of patients referred pre- (2013) and post-intervention (2014). We found high fidelity to the RaDIANT multicomponent intervention at the majority of intervention facilities, with sustainability of select intervention components at intervention facilities and feasibility for dissemination across ESRD Networks. Future modification of the intervention should emphasize financial education regarding kidney transplantation and amend intervention components that facilities perceive as time-intensive or non-sustainable. Clinicaltrials.gov number NCT02092727 . Registered 13 Mar 2014 (retrospectively registered).

  18. Large-area sheet task advanced dendritic web growth development

    NASA Technical Reports Server (NTRS)

    Duncan, C. S.; Seidensticker, R. G.; Mchugh, J. P.; Hopkins, R. H.; Meier, D.; Schruben, J.

    1982-01-01

    The thermal stress model was used to generate the design of a low stress lid and shield configuration, which was fabricated and tested experimentally. In preliminary tests, the New Experimental Web Growth Facility performed as designed, producing web on the first run. These experiments suggested desirable design modifications in the melt level sensing system to improve further its performance, and these are being implemented.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Piette, Mary Ann; Sezgen, Osman; Watson, David S.

    This report describes the results of a research project to develop and evaluate the performance of new Automated Demand Response (Auto-DR) hardware and software technology in large facilities. Demand Response (DR) is a set of activities to reduce or shift electricity use to improve electric grid reliability, manage electricity costs, and ensure that customers receive signals that encourage load reduction during times when the electric grid is near its capacity. The two main drivers for widespread demand responsiveness are the prevention of future electricity crises and the reduction of electricity prices. Additional goals for price responsiveness include equity through costmore » of service pricing, and customer control of electricity usage and bills. The technology developed and evaluated in this report could be used to support numerous forms of DR programs and tariffs. For the purpose of this report, we have defined three levels of Demand Response automation. Manual Demand Response involves manually turning off lights or equipment; this can be a labor-intensive approach. Semi-Automated Response involves the use of building energy management control systems for load shedding, where a preprogrammed load shedding strategy is initiated by facilities staff. Fully-Automated Demand Response is initiated at a building or facility through receipt of an external communications signal--facility staff set up a pre-programmed load shedding strategy which is automatically initiated by the system without the need for human intervention. We have defined this approach to be Auto-DR. An important concept in Auto-DR is that a facility manager is able to ''opt out'' or ''override'' an individual DR event if it occurs at a time when the reduction in end-use services is not desirable. This project sought to improve the feasibility and nature of Auto-DR strategies in large facilities. The research focused on technology development, testing, characterization, and evaluation relating to Auto-DR. This evaluation also included the related decisionmaking perspectives of the facility owners and managers. Another goal of this project was to develop and test a real-time signal for automated demand response that provided a common communication infrastructure for diverse facilities. The six facilities recruited for this project were selected from the facilities that received CEC funds for new DR technology during California's 2000-2001 electricity crises (AB970 and SB-5X).« less

  20. The effect of state policies on nursing home resident outcomes.

    PubMed

    Mor, Vincent; Gruneir, Andrea; Feng, Zhanlian; Grabowski, David C; Intrator, Orna; Zinn, Jacqueline

    2011-01-01

    To test the effect of changes in Medicaid reimbursement on clinical outcomes of long-stay nursing home (NH) residents. Longitudinal, retrospective study of NHs, merging aggregated resident-level quality measures with facility characteristics and state policy survey data. All free-standing NHs in urban counties with at least 20 long-stay residents per quarter (length of stay > 90 days) in the continental United States between 1999 and 2005. Long-stay NH residents Annual state Medicaid average per diem reimbursement and the presence of case-mix reimbursement in each year. Quarterly facility-aggregated, risk-adjusted quality-of-care measures surpassing a threshold for functional (activity of daily living) decline, physical restraint use, pressure ulcer incidence or worsening, and persistent pain. All outcomes showed an improvement trend over the study period, particularly physical restraint use. Facility fixed-effect regressions revealed that a $10 increase in Medicaid payment increased the likelihood of a NH meeting quality thresholds by 9% for functional decline, 5% for pain control, and 2% for pressure ulcers but not reduced use of physical restraints. Facilities in states that increased Medicaid payment most showed the greatest improvement in outcomes. The introduction of case-mix reimbursement was unrelated to quality improvement. Improvements in the clinical quality of NH care have been achieved, particularly where Medicaid payment has increased, generally from a lower baseline. Although this is a positive finding, challenges to implementing efficient reimbursement policies remain. © 2010, Copyright the Authors. Journal compilation © 2010, The American Geriatrics Society.

  1. Acoustic Quality of the 40- by 80- Foot Wind Tunnel Test Section After Installation of a Deep Acoustic Lining

    NASA Technical Reports Server (NTRS)

    Soderman, Paul T.; Jaeger, Stephen M.; Hayes, Julie A.; Allen, Christopher S.

    2002-01-01

    A recessed, 42-inch deep acoustic lining has been designed and installed in the 40- by 80- Foot Wind Tunnel (40x80) test section to greatly improve the acoustic quality of the facility. This report describes the test section acoustic performance as determined by a detailed static calibration-all data were acquired without wind. Global measurements of sound decay from steady noise sources showed that the facility is suitable for acoustic studies of jet noise or similar randomly generated sound. The wall sound absorption, size of the facility, and averaging effects of wide band random noise all tend to minimize interference effects from wall reflections. The decay of white noise with distance was close to free field above 250 Hz. However, tonal sound data from propellers and fans, for example, will have an error band to be described that is caused by the sensitivity of tones to even weak interference. That error band could be minimized by use of directional instruments such as phased microphone arrays. Above 10 kHz, air absorption began to dominate the sound field in the large test section, reflections became weaker, and the test section tended toward an anechoic environment as frequency increased.

  2. A calibration loop to test hot-wire response under supercritical conditions

    NASA Astrophysics Data System (ADS)

    Radulović, Ivana; Vukoslavčević, P. V.; Wallace, J. M.

    2004-11-01

    A calibration facility to test the response of hot-wires in CO2 flow under supercritical conditions has been designed and constructed. It is capable of inducing variable speeds at different temperatures and pressures in the ranges of 0.15 - 2 m/s, 15 - 70 deg. C and 1 - 100 bar. The facility is designed as a closed loop with a test section, pump, electrical heater, DC motor and different regulating and measuring devices. The test section is a small tunnel, with a diffuser, honeycomb, screens and a nozzle to provide a uniform flow with a low turbulence level. The speed variation is created by a sealed, magnetic driven gear pump, with a variable rpm DC motor. Using the electrical heater and regulating the amount of CO2 in the facility, the desired temperature and pressure can be reached. The dimensions of the instalation are minimized to reduce the heat, pump power required, and CO2 consumption and to optimize safety. Preliminary testing of a single hot-wire velocity sensor at constant pressure (80 bar) and variable speed and temperature will be briefly described. The hot-wire probes calibrated in this loop will be used to measure turbulence properties in supercritical CO2 in support of improved designs of nuclear reactors to be cooled by supercritical fluids.

  3. Virtual machine provisioning, code management, and data movement design for the Fermilab HEPCloud Facility

    NASA Astrophysics Data System (ADS)

    Timm, S.; Cooper, G.; Fuess, S.; Garzoglio, G.; Holzman, B.; Kennedy, R.; Grassano, D.; Tiradani, A.; Krishnamurthy, R.; Vinayagam, S.; Raicu, I.; Wu, H.; Ren, S.; Noh, S.-Y.

    2017-10-01

    The Fermilab HEPCloud Facility Project has as its goal to extend the current Fermilab facility interface to provide transparent access to disparate resources including commercial and community clouds, grid federations, and HPC centers. This facility enables experiments to perform the full spectrum of computing tasks, including data-intensive simulation and reconstruction. We have evaluated the use of the commercial cloud to provide elasticity to respond to peaks of demand without overprovisioning local resources. Full scale data-intensive workflows have been successfully completed on Amazon Web Services for two High Energy Physics Experiments, CMS and NOνA, at the scale of 58000 simultaneous cores. This paper describes the significant improvements that were made to the virtual machine provisioning system, code caching system, and data movement system to accomplish this work. The virtual image provisioning and contextualization service was extended to multiple AWS regions, and to support experiment-specific data configurations. A prototype Decision Engine was written to determine the optimal availability zone and instance type to run on, minimizing cost and job interruptions. We have deployed a scalable on-demand caching service to deliver code and database information to jobs running on the commercial cloud. It uses the frontiersquid server and CERN VM File System (CVMFS) clients on EC2 instances and utilizes various services provided by AWS to build the infrastructure (stack). We discuss the architecture and load testing benchmarks on the squid servers. We also describe various approaches that were evaluated to transport experimental data to and from the cloud, and the optimal solutions that were used for the bulk of the data transport. Finally, we summarize lessons learned from this scale test, and our future plans to expand and improve the Fermilab HEP Cloud Facility.

  4. Virtual Machine Provisioning, Code Management, and Data Movement Design for the Fermilab HEPCloud Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Timm, S.; Cooper, G.; Fuess, S.

    The Fermilab HEPCloud Facility Project has as its goal to extend the current Fermilab facility interface to provide transparent access to disparate resources including commercial and community clouds, grid federations, and HPC centers. This facility enables experiments to perform the full spectrum of computing tasks, including data-intensive simulation and reconstruction. We have evaluated the use of the commercial cloud to provide elasticity to respond to peaks of demand without overprovisioning local resources. Full scale data-intensive workflows have been successfully completed on Amazon Web Services for two High Energy Physics Experiments, CMS and NOνA, at the scale of 58000 simultaneous cores.more » This paper describes the significant improvements that were made to the virtual machine provisioning system, code caching system, and data movement system to accomplish this work. The virtual image provisioning and contextualization service was extended to multiple AWS regions, and to support experiment-specific data configurations. A prototype Decision Engine was written to determine the optimal availability zone and instance type to run on, minimizing cost and job interruptions. We have deployed a scalable on-demand caching service to deliver code and database information to jobs running on the commercial cloud. It uses the frontiersquid server and CERN VM File System (CVMFS) clients on EC2 instances and utilizes various services provided by AWS to build the infrastructure (stack). We discuss the architecture and load testing benchmarks on the squid servers. We also describe various approaches that were evaluated to transport experimental data to and from the cloud, and the optimal solutions that were used for the bulk of the data transport. Finally, we summarize lessons learned from this scale test, and our future plans to expand and improve the Fermilab HEP Cloud Facility.« less

  5. Impact of academic facility type and volume on post-surgical outcomes following diagnosis of glioblastoma.

    PubMed

    Hauser, Alan; Dutta, Sunil W; Showalter, Timothy N; Sheehan, Jason P; Grover, Surbhi; Trifiletti, Daniel M

    2018-01-01

    To identify if facility type and/or facility volume impact overall survival (OS) following diagnosis of glioblastoma (GBM). We also sought to compare early post-surgical outcomes based on these factors. The National Cancer Database was queried for patients with GBM diagnosed from 2004 to 2013 with known survival. Patients were grouped based on facility type and facility volume. Multivariable analyses were performed to investigate factors associated OS following diagnosis and Chi-square tests were used to compare early post-surgical outcomes. 89,839 patients met inclusion criteria. Factors associated with improved OS on multivariable analysis included younger patient age, female gender, race, lower comorbidity score, higher performance score, smaller tumor size, unifocal tumors, MGMT hypermethylation, fully resected tumors, radiotherapy, and chemotherapy (each p < .001). Also, OS was improved among patients treated at centers averaging at least 30.2 cases per year (HR 0.948, compared to <7.4 cases/year, p < .001), and patients treated at Academic/Research programs had improved survival compared to those treated at Comprehensive Community Cancer programs (HR 1.069, p < .001) and Integrated Network Cancer programs (HR 1.126, p < .001). Similarly, Academic/Research programs and high volume centers demonstrated improved 30- and 90-day morality as well as 30-day readmission rates (p < .001). This study suggests that patients treated in Academic/Research programs and high patient-volume centers have increased survival and more favorable early-postsurgical outcomes. The extent to which differences in patient populations, socioeconomic factors, and/or provider expertise play into this cause will be areas of future research. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. The Granite Mountain Atmospheric Sciences Testbed (GMAST): A Facility for Long Term Complex Terrain Airflow Studies

    NASA Astrophysics Data System (ADS)

    Zajic, D.; Pace, J. C.; Whiteman, C. D.; Hoch, S.

    2011-12-01

    This presentation describes a new facility at Dugway Proving Ground (DPG), Utah that can be used to study airflow over complex terrain, and to evaluate how airflow over a mountain barrier affects wind patterns over adjacent flatter terrain. DPG's primary mission is to conduct testing, training, and operational assessments of chemical and biological weapon systems. These operations require very precise weather forecasts. Most test operations at DPG are conducted on fairly flat test ranges having uniform surface cover, where airflow patterns are generally well-understood. However, the DPG test ranges are located alongside large, isolated mountains, most notably Granite Mountain, Camelback Mountain, and the Cedar Mountains. Airflows generated over, or influenced by, these mountains can affect wind patterns on the test ranges. The new facility, the Granite Mountain Atmospheric Sciences Testbed, or GMAST, is designed to facilitate studies of airflow interactions with topography. This facility will benefit DPG by improving understanding of how mountain airflows interact with the test range conditions. A core infrastructure of weather sensors around and on Granite Mountain has been developed including instrumented towers and remote sensors, along with automated data collection and archival systems. GMAST is expected to be in operation for a number of years and will provide a reference domain for mountain meteorology studies, with data useful for analysts, modelers and theoreticians. Visiting scientists are encouraged to collaborate with DPG personnel to utilize this valuable scientific resource and to add further equipment and scientific designs for both short-term and long-term atmospheric studies. Several of the upcoming MATERHORN (MountAin TERrain atmospHeric mOdeling and obseRvatioNs) project field tests will be conducted at DPG, giving an example of GMAST utilization and collaboration between DPG and visiting scientists.

  7. Research and test facilities

    NASA Technical Reports Server (NTRS)

    1993-01-01

    A description is given of each of the following Langley research and test facilities: 0.3-Meter Transonic Cryogenic Tunnel, 7-by 10-Foot High Speed Tunnel, 8-Foot Transonic Pressure Tunnel, 13-Inch Magnetic Suspension & Balance System, 14-by 22-Foot Subsonic Tunnel, 16-Foot Transonic Tunnel, 16-by 24-Inch Water Tunnel, 20-Foot Vertical Spin Tunnel, 30-by 60-Foot Wind Tunnel, Advanced Civil Transport Simulator (ACTS), Advanced Technology Research Laboratory, Aerospace Controls Research Laboratory (ACRL), Aerothermal Loads Complex, Aircraft Landing Dynamics Facility (ALDF), Avionics Integration Research Laboratory, Basic Aerodynamics Research Tunnel (BART), Compact Range Test Facility, Differential Maneuvering Simulator (DMS), Enhanced/Synthetic Vision & Spatial Displays Laboratory, Experimental Test Range (ETR) Flight Research Facility, General Aviation Simulator (GAS), High Intensity Radiated Fields Facility, Human Engineering Methods Laboratory, Hypersonic Facilities Complex, Impact Dynamics Research Facility, Jet Noise Laboratory & Anechoic Jet Facility, Light Alloy Laboratory, Low Frequency Antenna Test Facility, Low Turbulence Pressure Tunnel, Mechanics of Metals Laboratory, National Transonic Facility (NTF), NDE Research Laboratory, Polymers & Composites Laboratory, Pyrotechnic Test Facility, Quiet Flow Facility, Robotics Facilities, Scientific Visualization System, Scramjet Test Complex, Space Materials Research Laboratory, Space Simulation & Environmental Test Complex, Structural Dynamics Research Laboratory, Structural Dynamics Test Beds, Structures & Materials Research Laboratory, Supersonic Low Disturbance Pilot Tunnel, Thermal Acoustic Fatigue Apparatus (TAFA), Transonic Dynamics Tunnel (TDT), Transport Systems Research Vehicle, Unitary Plan Wind Tunnel, and the Visual Motion Simulator (VMS).

  8. Can a quality improvement project impact maternal and child health outcomes at scale in northern Ghana?

    PubMed

    Singh, Kavita; Brodish, Paul; Speizer, Ilene; Barker, Pierre; Amenga-Etego, Issac; Dasoberi, Ireneous; Kanyoke, Ernest; Boadu, Eric A; Yabang, Elma; Sodzi-Tettey, Sodzi

    2016-06-16

    Quality improvement (QI) interventions are becoming more common in low- and middle-income countries, yet few studies have presented impact evaluations of these approaches. In this paper, we present an impact evaluation of a scale-up phase of 'Project Fives Alive!', a QI intervention in Ghana that aims to improve maternal and child health outcomes. 'Project Fives Alive!' employed a QI methodology to recognize barriers to care-seeking and care provision at the facility level and then to identify, test and implement simple and low-cost local solutions that address the barriers. A quasi-experimental design, multivariable interrupted time series analysis, with data coming from 744 health facilities and controlling for potential confounding factors, was used to study the effect of the project. The key independent variables were the change categories (interventions implemented) and implementation phase - Wave 2a (early phase) versus Wave 2b (later phase). The outcomes studied were early antenatal care (ANC), skilled delivery, facility-level under-five mortality and attendance of underweight infants at child welfare clinics. We stratified the analysis by facility type, namely health posts, health centres and hospitals. Several of the specific change categories were significantly associated with improved outcomes. For example, three of five change categories (early ANC, four or more ANC visits and skilled delivery/immediate postnatal care (PNC)) for health posts and two of five change categories (health education and triage) for hospitals were associated with increased skilled delivery. These change categories were associated with increases in skilled delivery varying from 28% to 58%. PNC changes for health posts and health centres were associated with greater attendance of underweight infants at child welfare clinics. The triage change category was associated with increased early antenatal care in hospitals. Intensity, the number of change categories tested, was associated with increased skilled delivery in health centres and reduced under-five mortality in hospitals. Using an innovative evaluation technique we determined that 'Project Fives Alive!' demonstrated impact at scale for the outcomes studied. The QI approach used by this project should be considered by other low- and middle-income countries in their efforts to improve maternal and child health.

  9. [Development and Effects of a Coping Skill Training Program for Caregivers in Feeding Difficulty of Older Adults with Dementia in Long-Term Care Facilities].

    PubMed

    Hong, Hyun Hwa; Gu, Mee Ock

    2018-04-01

    We developed and tested the effects of a coping skill training program for caregivers in feeding difficulty among older adults with dementia in long-term care facilities. A non-equivalent control group pretest-posttest design was used. The subjects comprised 34 caregivers (experimental group: 17, control group: 17) and 40 older adults with dementia (experimental group: 20, control group: 20). The developed program was delivered in 4-hour sessions over 6 weeks (including 2 weeks of lectures and lab practice on feeding difficulty coping skills, and 4 weeks of field practice). Data were collected before, immediately after, and 4 weeks after the program (January 3 to April 6, 2016). The data were analyzed using t-test and repeated measures ANOVA using SPSS/WIN 20.0. Compared to their counterparts in the control group, caregivers in the experimental group showed a significantly greater improvement in feeding knowledge and feeding behavior, while older adults with dementia showed greater improvements in feeding difficulty and Body Mass Index. The study findings indicate that this coping skill training program for caregivers in feeding difficulty is an effective intervention for older adults with dementia in long-term care facilities. © 2018 Korean Society of Nursing Science.

  10. Schlieren System Enhancements at GRC

    NASA Technical Reports Server (NTRS)

    Woike, Mark; Clem, Michelle M.

    2013-01-01

    This presentation describes the latest improvements that have been made to the Schlieren systems at the NASA Glenn Research Center. These systems are used for the visualization of flow and shock structures in our wind tunnel test facilities. Improvements have been made to the optics, light sources and knife edges using the latest state-of-the-art technology. The eventual goal of this upgrade work is to improve the sensitivity of the systems so that they can be used to make quantitative flow measurements.

  11. Spatial association of public sports facilities with body mass index in Korea.

    PubMed

    Han, Eun Jin; Kang, Kiyeon; Sohn, So Young

    2018-05-07

    Governments and also local councils create and enforce their own regional public health care plans for the problem of overweight and obesity in the population. Public sports facilities can help these plans. In this paper, we investigated the contribution of public sports facilities to the reduction of the obesity of local residents. We used the data obtained from the Fifth Korea National Health and Nutrition Examination Surveys; and measured the degree of obesity using body mass index (BMI). We conducted various spatial regression analyses including the global Moran's I test and local indicators of spatial autocorrelation analysis finding that there exists spatial dependence in the error term of spatial regression model for BMI. However, we also observed that the number of local public sports facilities is not significantly related to local BMI. This result can be caused by the low utilization ratio and an unbalanced spatial distribution of local public sports facilities. Based on our findings, we suggest that local councils need to improve the quality of public sports facilities encouraging the establishment of preferred types of pubic sports facilities.

  12. NEXT GENERATION ANALYSIS SOFTWARE FOR COMPONENT EVALUATION - Results of Rotational Seismometer Evaluation

    NASA Astrophysics Data System (ADS)

    Hart, D. M.; Merchant, B. J.; Abbott, R. E.

    2012-12-01

    The Component Evaluation project at Sandia National Laboratories supports the Ground-based Nuclear Explosion Monitoring program by performing testing and evaluation of the components that are used in seismic and infrasound monitoring systems. In order to perform this work, Component Evaluation maintains a testing facility called the FACT (Facility for Acceptance, Calibration, and Testing) site, a variety of test bed equipment, and a suite of software tools for analyzing test data. Recently, Component Evaluation has successfully integrated several improvements to its software analysis tools and test bed equipment that have substantially improved our ability to test and evaluate components. The software tool that is used to analyze test data is called TALENT: Test and AnaLysis EvaluatioN Tool. TALENT is designed to be a single, standard interface to all test configuration, metadata, parameters, waveforms, and results that are generated in the course of testing monitoring systems. It provides traceability by capturing everything about a test in a relational database that is required to reproduce the results of that test. TALENT provides a simple, yet powerful, user interface to quickly acquire, process, and analyze waveform test data. The software tool has also been expanded recently to handle sensors whose output is proportional to rotation angle, or rotation rate. As an example of this new processing capability, we show results from testing the new ATA ARS-16 rotational seismometer. The test data was collected at the USGS ASL. Four datasets were processed: 1) 1 Hz with increasing amplitude, 2) 4 Hz with increasing amplitude, 3) 16 Hz with increasing amplitude and 4) twenty-six discrete frequencies between 0.353 Hz to 64 Hz. The results are compared to manufacture-supplied data sheets.

  13. Status of molten carbonate fuel cell technology development

    NASA Astrophysics Data System (ADS)

    Parsons, E. L., Jr.; Williams, M. C.; George, T. J.

    The MCFC technology has been identified by the DOE as a promising product for commercialization. Development of the MCFC technology supports the National Energy Strategy. Review of the status of the MCFC technology indicates that the MCFC technology developers are making rapid and significant progress. Manufacturing facility development and extensive testing is occurring. Improvements in performance (power density), lower costs, improved packaging, and scale up to full height are planned. MCFC developers need to continue to be responsive to end-users in potential markets. It will be market demands for the correct product definition which will ultimately determine the character of MCFC power plants. There is a need for continued MCFC product improvement and multiple product development tests.

  14. Diode Laser Diagnostics of High Speed Flows (Postprint)

    DTIC Science & Technology

    2006-10-01

    Tests were conducted in the Research Cell 18 direct connect wind tunnel facility at WPAFB. TDLAS was used to detect water and oxygen at...the measurements and provide, in essence, an internal standard for the development of the oxygen sensor . American Institute of Aeronautics and...definitely improves SNR if fast flow noise dominates as in this case. The improved optical and electronic TDLAS system detected water and oxygen at

  15. ATR NSUF Instrumentation Enhancement Efforts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Joy L. Rempe; Mitchell K. Meyer; Darrell L. Knudson

    A key component of the Advanced Test Reactor (ATR) National Scientific User Facility (NSUF) effort is to expand instrumentation available to users conducting irradiation tests in this unique facility. In particular, development of sensors capable of providing real-time measurements of key irradiation parameters is emphasized because of their potential to increase data fidelity and reduce posttest examination costs. This paper describes the strategy for identifying new instrumentation needed for ATR irradiations and the program underway to develop and evaluate new sensors to address these needs. Accomplishments from this program are illustrated by describing new sensors now available to users ofmore » the ATR NSUF. In addition, progress is reported on current research efforts to provide improved in-pile instrumentation to users.« less

  16. Electromagnetic Interference/Compatibility (EMI/EMC) Control Test and Measurement Facility: User Test Planning Guide

    NASA Technical Reports Server (NTRS)

    Scully, Robert C.

    2011-01-01

    Test process, milestones and inputs are unknowns to first-time users of the EMI/EMC Test Facility. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  17. Performance needs assessment of maternal and newborn health service delivery in urban and rural areas of Osun State, South-West, Nigeria.

    PubMed

    Esan, Oluwaseun T; Fatusi, Adesegun O

    2014-06-01

    The study aimed to determine performance and compare gaps in maternal and newborn health (MNH) services in urban and rural areas of Osun State, Nigeria, to inform decisions for improved services. This study involved 14 urban and 10 rural-based randomly selected PHC facilities. Using a Performance Needs Assessment framework, desired performances were determined by key stakeholders and actual performances measured by conducting facility survey. Questionnaire interview of 143 health workers and 153 antenatal clients were done. Performance gaps were determined for the urban and rural areas and compared using Chi-square tests with SPSS version 17. PHC facilities and health workers in Osun State, Nigeria, were found to have significant gaps in MNH service performance and this was worse in the rural areas. Root cause of most of the performance gaps was poor political will of local government authorities. Improved government commitment to MNH is needful to address most of the gaps.

  18. Modeling and HIL Simulation of Flight Conditions Simulating Control System for the Altitude Test Facility

    NASA Astrophysics Data System (ADS)

    Zhou, Jun; Shen, Li; Zhang, Tianhong

    2016-12-01

    Simulated altitude test is an essential exploring, debugging, verification and validation means during the development of aero-engine. Free-jet engine test can simulate actual working conditions of aero-engine more realistically than direct-connect engine test but with relatively lower cost compared to propulsion wind tunnel test, thus becoming an important developing area of simulated altitude test technology. The Flight Conditions Simulating Control System (FCSCS) is of great importance to the Altitude Test Facility (ATF) but the development of that is a huge challenge. Aiming at improving the design efficiency and reducing risks during the development of FCSCS for ATFs, a Hardware- in-the-Loop (HIL) simulation system was designed and the mathematical models of key components such as the pressure stabilizing chamber, free-jet nozzle, control valve and aero-engine were built in this paper. Moreover, some HIL simulation experiments were carried out. The results show that the HIL simulation system designed and established in this paper is reasonable and effective, which can be used to adjust control parameters conveniently and assess the software and hardware in the control system immediately.

  19. Patient-, health worker-, and health facility-level determinants of correct malaria case management at publicly funded health facilities in Malawi: results from a nationally representative health facility survey.

    PubMed

    Steinhardt, Laura C; Chinkhumba, Jobiba; Wolkon, Adam; Luka, Madalitso; Luhanga, Misheck; Sande, John; Oyugi, Jessica; Ali, Doreen; Mathanga, Don; Skarbinski, Jacek

    2014-02-20

    Prompt and effective case management is needed to reduce malaria morbidity and mortality. However, malaria diagnosis and treatment is a multistep process that remains problematic in many settings, resulting in missed opportunities for effective treatment as well as overtreatment of patients without malaria. Prior to the widespread roll-out of malaria rapid diagnostic tests (RDTs) in late 2011, a national, cross-sectional, complex-sample, health facility survey was conducted in Malawi to assess patient-, health worker-, and health facility-level factors associated with malaria case management quality using multivariate Poisson regression models. Among the 2,019 patients surveyed, 34% had confirmed malaria defined as presence of fever and parasitaemia on a reference blood smear. Sixty-seven per cent of patients with confirmed malaria were correctly prescribed the first-line anti-malarial, with most cases of incorrect treatment due to missed diagnosis; 31% of patients without confirmed malaria were overtreated with an anti-malarial. More than one-quarter of patients were not assessed for fever or history of fever by health workers. The most important determinants of correct malaria case management were patient-level clinical symptoms, such as spontaneous complaint of fever to health workers, which increased both correct treatment and overtreatment by 72 and 210%, respectively (p<0.0001). Complaint of cough was associated with a 27% decreased likelihood of correct malaria treatment (p=0.001). Lower-level cadres of health workers were more likely to prescribe anti-malarials for patients, increasing the likelihood of both correct treatment and overtreatment, but no other health worker or health facility-level factors were significantly associated with case management quality. Introduction of RDTs holds potential to improve malaria case management in Malawi, but health workers must systematically assess all patients for fever, and then test and treat accordingly, otherwise, malaria control programmes might miss an opportunity to dramatically improve malaria case management, despite better diagnostic tools.

  20. Overview of the Orion Vibroacoustic Test Capability at NASA Glenn Research Center

    NASA Technical Reports Server (NTRS)

    Hughes, William O.; Hozman, Aron D.; McNelis, Mark E.; Otten, Kim D.

    2008-01-01

    In order to support the environmental test needs for our new Orion and Constellation program, NASA is developing unique world-class test facilities. To optimize this testing of spaceflight hardware while minimizing transportation issues, a one-stop, under one roof test capability is being developed at the Space Power Facility at the NASA Glenn Research Center's Plum Brook Station. This facility will provide the capability to perform the following environmental testing: (1) reverberation acoustic testing, (2) mechanical base-shake sine testing, (3) modal testing, (4) thermal-vacuum testing, and (5) EMI/EMC (electromagnetic interference and compatibility) testing. An overview of this test capability will be provided in this presentation, with special focus on the two new vibroacoustic test facilities currently being designed and built, the Reverberant Acoustic Test Facility (RATF) and the Mechanical Vibration Facility (MVF). Testing of the engineering developmental hardware and qualification hardware of the Orion (Crew Exploration Vehicle) will commence shortly after the facilities are commissioned.

  1. Service quality in contracted facilities.

    PubMed

    Rabbani, Fauziah; Pradhan, Nousheen Akber; Zaidi, Shehla; Azam, Syed Iqbal; Yousuf, Farheen

    2015-01-01

    The purpose of this paper is to explore the readiness of contracted and non-contracted first-level healthcare facilities in Pakistan to deliver quality maternal and neonatal health (MNH) care. A balanced scorecard (BSC) was used as the assessment framework. Using a cross-sectional study design, two rural health centers (RHCs) contracted out to Aga Khan Health Service, Pakistan were compared with four government managed RHCs. A BSC was designed to assess RHC readiness to deliver good quality MNH care. In total 20 indicators were developed, representing five BSC domains: health facility functionality, service provision, staff capacity, staff and patient satisfaction. Validated data collection tools were used to collect information. Pearson χ2, Fisher's Exact and the Mann-Whitney tests were applied as appropriate to detect significant service quality differences among the two facilities. Contracted facilities were generally found to be better than non-contracted facilities in all five BSC domains. Patients' inclination for facility-based delivery at contracted facilities was, however, significantly higher than non-contracted facilities (80 percent contracted vs 43 percent non-contracted, p=0.006). The study shows that contracting out initiatives have the potential to improve MNH care. This is the first study to compare MNH service delivery quality across contracted and non-contracted facilities using BSC as the assessment framework.

  2. New cleaning technologies advance coal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Onursal, B.

    1984-05-01

    Alternative options are discussed for reducing sulfur dioxide emissions from coal burning utility and industrial sources. Test results indicate that it may be most advantageous to use the AED Process after coal preparation or on coals that do not need much ash removal. However, the developer claims that research efforts after 1981 have led to process improvements for producing clean coals containing 1.5% to 3% ash. This paper describes the test facility where a full-scale test of the AED Process is underway.

  3. Survey of solar thermal test facilities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Masterson, K.

    The facilities that are presently available for testing solar thermal energy collection and conversion systems are briefly described. Facilities that are known to meet ASHRAE standard 93-77 for testing flat-plate collectors are listed. The DOE programs and test needs for distributed concentrating collectors are identified. Existing and planned facilities that meet these needs are described and continued support for most of them is recommended. The needs and facilities that are suitable for testing components of central receiver systems, several of which are located overseas, are identified. The central contact point for obtaining additional details and test procedures for these facilitiesmore » is the Solar Thermal Test Facilities Users' Association in Albuquerque, N.M. The appendices contain data sheets and tables which give additional details on the technical capabilities of each facility. Also included is the 1975 Aerospace Corporation report on test facilities that is frequently referenced in the present work.« less

  4. NREL’s Controllable Grid Interface Saves Time and Resources, Improves Reliability of Renewable Energy Technologies; NREL (National Renewable Energy Laboratory)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    The National Renewable Energy Laboratory's (NREL) controllable grid interface (CGI) test system at the National Wind Technology Center (NWTC) is one of two user facilities at NREL capable of testing and analyzing the integration of megawatt-scale renewable energy systems. The CGI specializes in testing of multimegawatt-scale wind and photovoltaic (PV) technologies as well as energy storage devices, transformers, control and protection equipment at medium-voltage levels, allowing the determination of the grid impacts of the tested technology.

  5. An Experimental Test Facility to Support Development of the Fluoride Salt Cooled High Temperature Reactor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yoder Jr, Graydon L; Aaron, Adam M; Cunningham, Richard Burns

    2014-01-01

    The need for high-temperature (greater than 600 C) energy exchange and delivery systems is significantly increasing as the world strives to improve energy efficiency and develop alternatives to petroleum-based fuels. Liquid fluoride salts are one of the few energy transport fluids that have the capability of operating at high temperatures in combination with low system pressures. The Fluoride Salt-Cooled High-Temperature Reactor design uses fluoride salt to remove core heat and interface with a power conversion system. Although a significant amount of experimentation has been performed with these salts, specific aspects of this reactor concept will require experimental confirmation during themore » development process. The experimental facility described here has been constructed to support the development of the Fluoride Salt Cooled High Temperature Reactor concept. The facility is capable of operating at up to 700 C and incorporates a centrifugal pump to circulate FLiNaK salt through a removable test section. A unique inductive heating technique is used to apply heat to the test section, allowing heat transfer testing to be performed. An air-cooled heat exchanger removes added heat. Supporting loop infrastructure includes a pressure control system; trace heating system; and a complement of instrumentation to measure salt flow, temperatures, and pressures around the loop. The initial experiment is aimed at measuring fluoride salt heat transfer inside a heated pebble bed similar to that used for the core of the pebble bed advanced high-temperature reactor. This document describes the details of the loop design, auxiliary systems used to support the facility, the inductive heating system, and facility capabilities.« less

  6. Activation of the E1 Ultra High Pressure Propulsion Test Facility at Stennis Space Center

    NASA Technical Reports Server (NTRS)

    Messer, Bradley; Messer, Elisabeth; Sewell, Dale; Sass, Jared; Lott, Jeff; Dutreix, Lionel, III

    2001-01-01

    After a decade of construction and a year of activation the El Ultra High Pressure Propulsion Test Facility at NASA's Stennis Space Center is fully operational. The El UHP Propulsion Test Facility is a multi-cell, multi-purpose component and engine test facility . The facility is capable of delivering cryogenic propellants at low, high, and ultra high pressures with flow rates ranging from a few pounds per second up to two thousand pounds per second. Facility activation is defined as a series of tasks required to transition between completion of construction and facility operational readiness. Activating the El UHP Propulsion Test Facility involved independent system checkouts, propellant system leak checks, fluid and gas sampling, gaseous system blow downs, pressurization and vent system checkouts, valve stability testing, valve tuning cryogenic cold flows, and functional readiness tests.

  7. Personal, interpersonal and structural challenges to accessing HIV testing, treatment and care services among female sex workers, men who have sex with men and transgenders in Karnataka state, South India.

    PubMed

    Beattie, Tara S H; Bhattacharjee, Parinita; Suresh, M; Isac, Shajy; Ramesh, B M; Moses, Stephen

    2012-10-01

    Despite high HIV prevalence rates among most-at-risk groups, utilisation of HIV testing, treatment and care services was relatively low in Karnataka prior to 2008. The authors aimed to understand the barriers to and identify potential solutions for improving HIV service utilisation. Focus group discussions were carried out among homogeneous groups of female sex workers, men who have sex with men and transgenders, and programme peer educators in six districts across Karnataka in March and April 2008. 26 focus group discussions were conducted, involving 302 participants. Participants had good knowledge about HIV and HIV voluntary counselling and testing (VCT) services, but awareness of other HIV services was low. The fear of the psychological impact of a positive HIV test result and the perceived repercussions of being seen accessing HIV services were key personal and interpersonal barriers to HIV service utilisation. Previous experiences of discrimination at government healthcare services, coupled with discriminatory attitudes and behaviours by VCT staff, were key structural barriers to VCT service uptake among those who had not been HIV tested. Among those who had used government-managed prevention of parent to child transmission and antiretroviral treatment services, poor physical facilities, long waiting times, lack of available treatment, the need to give bribes to receive care and discriminatory attitudes of healthcare staff presented additional structural barriers. Embedding some HIV care services within existing programmes for vulnerable populations, as well as improving service quality at government facilities, are suggested to help overcome the multiple barriers to service utilisation. Increasing the uptake of HIV testing, treatment and care services is key to improving the quality and longevity of the lives of HIV-infected individuals.

  8. KSC ground operations planning for Space Station

    NASA Technical Reports Server (NTRS)

    Lyon, J. R.; Revesz, W., Jr.

    1993-01-01

    At the Kennedy Space Center (KSC) in Florida, processing facilities are being built and activated to support the processing, checkout, and launch of Space Station elements. The generic capability of these facilities will be utilized to support resupply missions for payloads, life support services, and propellants for the 30-year life of the program. Special Ground Support Equipment (GSE) is being designed for Space Station hardware special handling requirements, and a Test, Checkout, and Monitoring System (TCMS) is under development to verify that the flight elements are ready for launch. The facilities and equipment used at KSC, along with the testing required to accomplish the mission, are described in detail to provide an understanding of the complexity of operations at the launch site. Assessments of hardware processing flows through KSC are being conducted to minimize the processing flow times for each hardware element. Baseline operations plans and the changes made to improve operations and reduce costs are described, recognizing that efficient ground operations are a major key to success of the Space Station.

  9. High Power MPD Thruster Development at the NASA Glenn Research Center

    NASA Technical Reports Server (NTRS)

    LaPointe, Michael R.; Mikellides, Pavlos G.; Reddy, Dhanireddy (Technical Monitor)

    2001-01-01

    Propulsion requirements for large platform orbit raising, cargo and piloted planetary missions, and robotic deep space exploration have rekindled interest in the development and deployment of high power electromagnetic thrusters. Magnetoplasmadynamic (MPD) thrusters can effectively process megawatts of power over a broad range of specific impulse values to meet these diverse in-space propulsion requirements. As NASA's lead center for electric propulsion, the Glenn Research Center has established an MW-class pulsed thruster test facility and is refurbishing a high-power steady-state facility to design, build, and test efficient gas-fed MPD thrusters. A complimentary numerical modeling effort based on the robust MACH2 code provides a well-balanced program of numerical analysis and experimental validation leading to improved high power MPD thruster performance. This paper reviews the current and planned experimental facilities and numerical modeling capabilities at the Glenn Research Center and outlines program plans for the development of new, efficient high power MPD thrusters.

  10. Lewis Research Center space station electric power system test facilities

    NASA Technical Reports Server (NTRS)

    Birchenough, Arthur G.; Martin, Donald F.

    1988-01-01

    NASA Lewis Research Center facilities were developed to support testing of the Space Station Electric Power System. The capabilities and plans for these facilities are described. The three facilities which are required in the Phase C/D testing, the Power Systems Facility, the Space Power Facility, and the EPS Simulation Lab, are described in detail. The responsibilities of NASA Lewis and outside groups in conducting tests are also discussed.

  11. Air STAR Beyond Visual Range UAS Description and Preliminary Test Results

    NASA Technical Reports Server (NTRS)

    Cunningham, Kevin; Cox, David E.; Foster, John V.; Riddick, Stephen E.; Laughter, Sean A.

    2016-01-01

    The NASA Airborne Subscale Transport Aircraft Research Unmanned Aerial System project's capabilities were expanded by updating the system design and concept of operations. The new remotely piloted airplane system design was flight tested to assess integrity and operational readiness of the design to perform flight research. The purpose of the system design is to improve aviation safety by providing a capability to validate, in high-risk conditions, technologies to prevent airplane loss of control. Two principal design requirements were to provide a high degree of reliability and that the new design provide a significant increase in test volume (relative to operations using the previous design). The motivation for increased test volume is to improve test efficiency and allow new test capabilities that were not possible with the previous design and concept of operations. Three successful test flights were conducted from runway 4-22 at NASA Goddard Space Flight Center's Wallops Flight Facility.

  12. Nuclear thermal propulsion test facility requirements and development strategy

    NASA Technical Reports Server (NTRS)

    Allen, George C.; Warren, John; Clark, J. S.

    1991-01-01

    The Nuclear Thermal Propulsion (NTP) subpanel of the Space Nuclear Propulsion Test Facilities Panel evaluated facility requirements and strategies for nuclear thermal propulsion systems development. High pressure, solid core concepts were considered as the baseline for the evaluation, with low pressure concepts an alternative. The work of the NTP subpanel revealed that a wealth of facilities already exists to support NTP development, and that only a few new facilities must be constructed. Some modifications to existing facilities will be required. Present funding emphasis should be on long-lead-time items for the major new ground test facility complex and on facilities supporting nuclear fuel development, hot hydrogen flow test facilities, and low power critical facilities.

  13. A microprocessor tester for the treat upgrade reactor trip system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lenkszus, F.R.; Bucher, R.G.

    1985-02-01

    The upgrading of the Transient Reactor Test (TREAT) Facility at ANL-Idaho has been designed to provide additional experimental capabilities for the study of core disruptive accident (CDA) phenomena. To improve the analytical extrapolation of test results to full-size assembly bundles, the facility upgrade will increase the maximum size of the test bundle from 7 to 37 fuel pins. By creating a core convertor zone around the test location, the neutron spectrum incident on the test assembly will be hardened and the maximum energy deposited in the sample will be increased. In addition, a programmable Automated Reactor Control System (ARCS) willmore » permit high-power transients up to 11,000 MW having a controlled reactor period of from 15 to 0.1 sec. These modifications to the core neutronics will improve simulation of LMFBR accident conditions. Finally, a sophisticated, multiply-redundant safety system, the Reactor Trip System (RTS), will provide safe operation for both steady state and transient production operating modes. To insure that this complex safety system is functioning properly, a Dedicated Microprocessor Tester (DMT) has been implemented to perform a thorough checkout of the RTS prior to all TREAT operations. A quantitative reliability analysis of the RTS shows that the unreliability, that is, the probability of failure, is acceptable for a 10 hour mission time or risk interval.« less

  14. 42 CFR 59a.4 - How are grant applications evaluated?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... LIBRARY OF MEDICINE GRANTS Grants for Establishing, Expanding, and Improving Basic Resources § 59a.4 How... Secretary's evaluation shall consider the scope of library or related services for the population and... coordination with other libraries and related facilities, and (d) Potential for testing or demonstration of new...

  15. Improve Carpet Life with Proper Installation.

    ERIC Educational Resources Information Center

    Grogan, Ralph

    1998-01-01

    Provides guidance on ways to extend carpet life in educational facilities by paying attention to the details of carpeting installation. Issues to consider include choosing carpeting to meet specific usage requirements, are fiber protectorants used, is the installation properly done by qualified installers, and is moisture testing done prior to…

  16. NRC visit

    NASA Image and Video Library

    2012-08-22

    Four members of the National Research Council visited Stennis Space Center on Aug. 22, touring test stands and facilities, and holding roundtable discussions with Stennis leaders. The NRC mission is to improve government decision making and public policy, increase public understanding, and promote the acquisition and dissemination of knowledge in matters involving science, engineering, technology and health.

  17. Evaluation of Liquefaction Susceptibility of Clean Sands after Blast Densification

    NASA Astrophysics Data System (ADS)

    Vega Posada, Carlos Alberto

    The effect of earthquakes on infrastructure facilities is an important topic of interest in geotechnical research. A key design issue for such facilities is whether or not liquefaction will occur during an earthquake. The consequences of this type of ground failure are usually severe, resulting in severe damage to a facility and in some cases the loss of human life. One approach to minimize the effect of liquefaction is to improve the ground condition by controlled blasting. The main limitations of the blast densification technique are that the design is mostly empirical and verification studies of densification have resulted in contradictory results in some case studies. In such cases, even though the ground surface settles almost immediately after blasting, common verification tests such as the cone penetration test (CPT), standard penetration test (SPT), and shear wave velocity test (Vs) suggest that the soil mass has not been improved at all. This raises concerns regarding the future performance of the soil and casts doubts on whether or not the improved deposit is still susceptible to liquefaction. In this work, a blast densification program was implemented at the Oakridge Landfill located in Dorchester County, SC, to gain information regarding the condition of a loose sand deposit during and after each blast event. In addition, an extensive laboratory testing program was conducted on reconstituted sand specimens to evaluate the mechanical behavior of saturated and gassy, medium dense sands during monotonic and cyclic loading. The results from the field and laboratory program indicate that gas released during blasting can remain trapped in the soil mass for several years, and this gas greatly affects the mechanical behavior of the sand. Gas greatly increases the liquefaction resistance of the soil. If the gas remains in the sand over the life of a project, then it will maintain this increased resistance to liquefaction, whether or not the penetration resistance increases with time. As part of this work, a methodology based on the critical state concepts was described to quantify the amount of densification needed at a certain project to make the soil more resistant to liquefaction and flow.

  18. Marshall Space Flight Center's Impact Testing Facility Capabilities

    NASA Technical Reports Server (NTRS)

    Evans, Steve; Finchum, Andy; Hubbs, Whitney; Gray, Perry

    2008-01-01

    Marshall Space Flight Center's (MSFC) Impact Testing Facility (ITF) serves as an important installation for space and missile related materials science research. The ITF was established and began its research in spacecraft debris shielding in the early 1960s, then played a major role in the International Space Station debris shield development. As NASA became more interested in launch debris and in-flight impact concerns, the ITF grew to include research in a variety of impact genres. Collaborative partnerships with the DoD led to a wider range of impact capabilities being relocated to MSFC as a result of the closure of Particle Impact Facilities in Santa Barbara, California, The Particle Impact Facility had a 30 year history in providing evaluations of aerospace materials and components during flights through rain, ice, and solid particle environments at subsonic through hypersonic velocities. The facility's unique capabilities were deemed a 'National Asset' by the DoD, The ITF now has capabilities including environmental, ballistic, and hypervelocity impact testing utilizing an array of air, powder, and two-stage light gas guns to accommodate a variety of projectile and target types and sizes. Relocated test equipment was dated and in need of upgrade. Numerous upgrades including new instrumentation, triggering circuitry, high speed photography, and optimized sabot designs have been implemented. Other recent research has included rain drop demise characterization tests to obtain data for inclusion in on-going model development. Future ITF improvements will be focused on continued instrumentation and performance enhancements. These enhancements will allow further, more in-depth, characterization of rain drop demise characterization and evaluation of ice crystal impact. Performance enhancements also include increasing the upper velocity limit of the current environmental guns to allow direct environmental simulation for missile components. The current and proposed ITF capabilities range from rain to micrometeoroids allowing the widest test parameter range possible for materials investigations in support of space, atmospheric, and ground environments. These test capabilities including hydrometeor, single/multi-particle, ballistic gas guns, exploding wire gun, and light gas guns combined with Smooth Particle Hydrodynamics Code (SPHC) simulations represent the widest range of impact test capabilities in the country.

  19. Marshall Space Flight Center's Impact Testing Facility Capabilities

    NASA Technical Reports Server (NTRS)

    Evans, Steve; Finchum, Andy; Hubbs, Whitney

    2008-01-01

    Marshall Space Flight Center's (MSFC) Impact Testing Facility (ITF) serves as an important installation for space and missile related materials science research. The ITF was established and began its research in spacecraft debris shielding in the early 1960% then played a major role in the International Space Station debris shield development. As NASA became more interested in launch debris and in-flight impact concerns, the ITF grew to include research in a variety of impact genres. Collaborative partnerships with the DoD led to a wider range of impact capabilities being relocated to MSFC as a result of the closure of Particle Impact Facilities in Santa Barbara, California. The Particle Impact Facility had a 30 year history in providing evaluations of aerospace materials and components during flights through rain, ice, and solid particle environments at subsonic through hypersonic velocities. The facility's unique capabilities were deemed a "National Asset" by the DoD. The ITF now has capabilities including environmental, ballistic, and hypervelocity impact testing utilizing an array of air, powder, and two-stage light gas guns to accommodate a variety of projectile and target types and sizes. Relocated test equipment was dated and in need of upgrade. Numerous upgrades including new instrumentation, triggering circuitry, high speed photography, and optimized sabot designs have been implemented. Other recent research has included rain drop demise characterization tests to obtain data for inclusion in on-going model development. Future ITF improvements will be focused on continued instrumentation and performance enhancements. These enhancements will allow further, more in-depth, characterization of rain drop demise characterization and evaluation of ice crystal impact. Performance enhancements also include increasing the upper velocity limit of the current environmental guns to allow direct environmental simulation for missile components. The current and proposed ITF capabilities range from rain to micrometeoroids allowing the widest test parameter range possible for materials investigations in support of space, atmospheric, and ground environments. These test capabilities including hydrometeor, single/multi-particle, ballistic gas grins, exploding wire gun, and light gas guns combined with Smooth Particle Hydrodynamics Code (SPHC) simulations represent the widest range of impact test capabilities in the country.

  20. Early assessment of the implementation of a national programme for the prevention of mother-to-child transmission of HIV in Cameroon and the effects of staff training: a survey in 70 rural health care facilities.

    PubMed

    Labhardt, Niklaus Daniel; Manga, Engelbert; Ndam, Mama; Balo, Jean-Richard; Bischoff, Alexandre; Stoll, Beat

    2009-03-01

    To assess the availability of equipment and the staff's knowledge to prevent Mother-To-Child Transmission (PMTCT) in rural healthcare facilities recently covered by the national PMTCT programme in Cameroon. In eight districts inventories of antiviral drugs and HIV test kits were made on site, using a standardised check-list. Knowledge of HIV and PMTCT was evaluated with a multiple-choice (MC) questionnaire based on typical clinical PMTCT cases. Staff participated subsequently in a 2-day training on HIV/AIDS and the Cameroon PMTCT guidelines. Immediately after training and after 7 months, retention of knowledge was tested with the same questions but in different order and layout. Sixty two peripheral nurse-led clinics and the eight district hospitals were assessed. Whereas all district hospitals presented complete equipment, only six of the peripheral clinics (10%) were equipped with both complete testing materials and a full set of drugs to provide PMTCT. Thirty six peripheral facilities (58%) possessed full equipment for HIV-testing and 8 (13%) stocked all PMTCT drugs. Of 137 nurses, 102 (74%) agreed to the two knowledge tests. Fewer than 66% knew that HIV-diagnosis requires positive results in two different types of rapid tests and only 19% chose the right recommendation on infant-feeding for HIV-positive mothers. Correct answers on drug regimens in different PMTCT settings varied from 25% to 56%. All percentages of correct answers improved greatly with training (P < 0.001) and retention remained high 7 months after training (P < 0.001). Prevent Mother-To-Child Transmission programmes in settings such as rural Cameroon need to be adapted to the special needs of peripheral nurse-led clinics. Appropriate short training may considerably improve nurses' competence in PMTCT. Other important components are regular supervision and measures to guarantee supply of equipment in rural areas.

  1. STD testing policies and practices in U.S. city and county jails.

    PubMed

    Parece, M S; Herrera, G A; Voigt, R F; Middlekauff, S L; Irwin, K L

    1999-09-01

    Studies have shown that sexually transmitted disease (STD) rates are high in the incarcerated population. However, little is known about STD testing policies or practices in jails. To assess STD testing policies and practices in jails. The Division of STD Prevention developed and distributed an e-mail survey to 94 counties reporting more than 40 primary and secondary cases in 1996 or having cities with more than 200,000 persons. State and local STD program managers completed the assessment in collaboration with health departments and the main jail facilities in the selected counties. Most facilities (52-77%) had a policy for STD screening based only on symptoms or by arrestee request, and in these facilities, 0.2% to 6% of arrestees were tested. Facilities having a policy of offering routine testing tested only 3% to 45% of arrestees. Large facilities, facilities using public providers, and facilities routinely testing for syphilis using Stat RPR tested significantly more arrestees (P<0.05). Approximately half of the arrestees were released within 48 hours after intake, whereas 45% of facilities did not have STD testing results until after 48 hours. Most facilities had a policy for STD screening based only on symptoms or by arrestee request. Facilities having a policy of routine STD testing are not testing most of the arrestees. There is a small window (<48 hours) for STD testing and treatment before release. Smaller jails and facilities using private providers may need additional resources to increase STD testing levels. Correctional facilities should be considered an important setting for STD public health intervention where routine rapid STD screening and treatment on-site could be implemented.

  2. The Effect of Performance-Based Financial Incentives on Improving Health Care Provision in Burundi: A Controlled Cohort Study

    PubMed Central

    Rudasingwa, Martin; Soeters, Robert; Bossuyt, Michel

    2015-01-01

    To strengthen the health care delivery, the Burundian Government in collaboration with international NGOs piloted performance-based financing (PBF) in 2006. The health facilities were assigned - by using a simple matching method - to begin PBF scheme or to continue with the traditional input-based funding. Our objective was to analyse the effect of that PBF scheme on the quality of health services between 2006 and 2008. We conducted the analysis in 16 health facilities with PBF scheme and 13 health facilities without PBF scheme. We analysed the PBF effect by using 58 composite quality indicators of eight health services: Care management, outpatient care, maternity care, prenatal care, family planning, laboratory services, medicines management and materials management. The differences in quality improvement in the two groups of health facilities were performed applying descriptive statistics, a paired non-parametric Wilcoxon Signed Ranks test and a simple difference-in-difference approach at a significance level of 5%. We found an improvement of the quality of care in the PBF group and a significant deterioration in the non-PBF group in the same four health services: care management, outpatient care, maternity care, and prenatal care. The findings suggest a PBF effect of between 38 and 66 percentage points (p<0.001) in the quality scores of care management, outpatient care, prenatal care, and maternal care. We found no PBF effect on clinical support services: laboratory services, medicines management, and material management. The PBF scheme in Burundi contributed to the improvement of the health services that were strongly under the control of medical personnel (physicians and nurses) in a short time of two years. The clinical support services that did not significantly improved were strongly under the control of laboratory technicians, pharmacists and non-medical personnel. PMID:25948432

  3. Magnetohydrodynamics Accelerator Research Into Advanced Hypersonics (MARIAH). Part 1

    NASA Technical Reports Server (NTRS)

    Micheletti, David A.; Baughman, Jack A.; Nelson, Gordon L.; Simmons, Gloyd A.

    1997-01-01

    This report documents the activities, results, conclusions and recommendations of the Magnetohydrodynamics Accelerator Research Into Advanced Hypersonics (MARIAH) Project in which the use of magnetohydrodynamics (MHD) technology is investigated for its applicability to augment hypersonic wind tunnels. The long range objective of this investigation is to advance the development of ground test facilities to support the development of hypervelocity flight vehicles. The MHD accelerator adds kinetic energy directly to the wind tunnel working fluid, thereby increasing its Mach number to hypervelocity levels. Several techniques for MHD augmentation, as well as other physical characteristics of the process are studied to enhance the overall performance of hypersonic wind tunnel design. Specific recommendations are presented to improve the effectiveness of ground test facilities. The work contained herein builds on nearly four decades of research and experimentation by the aeronautics ground test and evaluation community, both foreign and domestic.

  4. Magnetohydrodynamics Accelerator Research into Advanced Hypersonics (MARIAH). Part 2

    NASA Technical Reports Server (NTRS)

    Baughman, Jack A.; Micheletti, David A.; Nelson, Gordon L.; Simmons, Gloyd A.

    1997-01-01

    This report documents the activities, results, conclusions and recommendations of the Magnetohydrodynamics Accelerator Research Into Advanced Hypersonics (MARIAH) Project in which the use of magnetohydrodynamics (MHD) technology is investigated for its applicability to augment hypersonic wind tunnels. The long range objective of this investigation is to advance the development of ground test facilities to support the development of hypervelocity flight vehicles. The MHD accelerator adds kinetic energy directly to the wind tunnel working fluid, thereby increasing its Mach number to hypervelocity levels. Several techniques for MHD augmentation, as well as other physical characteristics of the process are studied to enhance the overall performance of hypersonic wind tunnel design. Specific recommendations are presented to improve the effectiveness of ground test facilities. The work contained herein builds on nearly four decades of research and experimentation by the aeronautics ground test and evaluation community, both foreign and domestic.

  5. Trends in family ratings of experience with care and racial disparities among Maryland nursing homes.

    PubMed

    Li, Yue; Ye, Zhiqiu; Glance, Laurent G; Temkin-Greener, Helena

    2014-07-01

    Providing equitable and patient-centered care is critical to ensuring high quality of care. Although racial/ethnic disparities in quality are widely reported for nursing facilities, it is unknown whether disparities exist in consumer experiences with care and how public reporting of consumer experiences affects facility performance and potential racial disparities. We analyzed trends of consumer ratings publicly reported for Maryland nursing homes during 2007-2010, and determined whether racial/ethnic disparities in experiences with care changed during this period. Multivariate longitudinal regression models controlled for important facility and county characteristics and tested changes overall and by facility groups (defined based on concentrations of black residents). Consumer ratings were reported for: overall care; recommendation of the facility; staff performance; care provided; food and meals; physical environment; and autonomy and personal rights. Overall ratings on care experience remained relatively high (mean=8.3 on a 1-10 scale) during 2007-2010. Ninety percent of survey respondents each year would recommend the facility to someone who needs nursing home care. Ratings on individual domains of care improved among all nursing homes in Maryland (P<0.01), except for food and meals (P=0.827 for trend). However, site-of-care disparities existed in each year for overall ratings, recommendation rate, and ratings on all domains of care (P<0.01 in all cases), with facilities more predominated by black residents having lower scores; such disparities persisted over time (P>0.2 for trends in disparities). Although Maryland nursing homes showed maintained or improved consumer ratings during the first 4 years of public reporting, gaps persisted between facilities with high versus low concentrations of minority residents.

  6. Protocol for Atomic Oxygen Testing of Materials in Ground-Based Facilities. No. 2

    NASA Technical Reports Server (NTRS)

    Minton, Timothy K.

    1995-01-01

    A second version of standard guidelines is proposed for improving materials testing in ground-based atomic oxygen environments for the purpose of predicting the durability of the tested materials in low Earth orbit (LEO). Accompanying these guidelines are background information and notes about testing. Both the guidelines and the additional information are intended to aid users who wish to evaluate the potential hazard of atomic oxygen in LEO to a candidate space component without actually flying the component in space, and to provide a framework for more consistent atomic oxygen testing in the future.

  7. Cost effectiveness as applied to the Viking Lander systems-level thermal development test program

    NASA Technical Reports Server (NTRS)

    Buna, T.; Shupert, T. C.

    1974-01-01

    The economic aspects of thermal testing at the systems-level as applied to the Viking Lander Capsule thermal development program are reviewed. The unique mission profile and pioneering scientific goals of Viking imposed novel requirements on testing, including the development of a simulation technique for the Martian thermal environment. The selected approach included modifications of an existing conventional thermal vacuum facility, and improved test-operational techniques that are applicable to the simulation of the other mission phases as well, thereby contributing significantly to the cost effectiveness of the overall thermal test program.

  8. SSME seal test program: Test results for smooth, hole-pattern and helically-grooved stators

    NASA Technical Reports Server (NTRS)

    Childs, Dara W.

    1987-01-01

    All of the listed seals were tested in a liquid Halon test facility at high Reynolds numbers. In addition, a helically-grooved-stator seal was tested in an air seal facility. An analysis of the test results with comparisons to theoretical predictions supports the following conclusions: (1) For small seals, the Hirs' friction-factor model is more restricted than had been thought; (2) For smooth seals, predictions of stiffness and damping improve markedly as the radical clearance is reduced; (3) Friction-factor data for hole-pattern-seal stators frequently deviates from the Hirs model; (4) Predictions of stiffness and damping coefficients for hole-pattern-stator seals is generally reasonable; (5) Tests for the hole-pattern stators at reduced clearances show no clear optimum for hole-pattern seals with respect to either hole-area ratio or hole depth to minimum clearance ratios; (6) Tests of these hole-pattern stators show no significant advantage in net damping over smooth seals; (7) Tests of helically-grooved seal stators in Halon show reasonable agreement between theory and prediction for leakage and direct stiffness but poor agreement for the net damping coefficient.

  9. Wake Shield Facility Modal Survey Test in Vibration Acoustic Test Facility

    NASA Image and Video Library

    1991-10-09

    Astronaut Ronald M. Sega stands beside the University of Houston's Wake Shield Facility before it undergoes a Modal Survey Test in the Vibration and Acoustic Test Facility Building 49, prior to being flown on space shuttle mission STS-60.

  10. Water facilities in retrospect and prospect: An illuminating tool for vehicle design

    NASA Technical Reports Server (NTRS)

    Erickson, G. E.; Peak, D. J.; Delfrate, J.; Skow, A. M.; Malcolm, G. N.

    1986-01-01

    Water facilities play a fundamental role in the design of air, ground, and marine vehicles by providing a qualitative, and sometimes quantitative, description of complex flow phenomena. Water tunnels, channels, and tow tanks used as flow-diagnostic tools have experienced a renaissance in recent years in response to the increased complexity of designs suitable for advanced technology vehicles. These vehicles are frequently characterized by large regions of steady and unsteady three-dimensional flow separation and ensuing vortical flows. The visualization and interpretation of the complicated fluid motions about isolated vehicle components and complete configurations in a time and cost effective manner in hydrodynamic test facilities is a key element in the development of flow control concepts, and, hence, improved vehicle designs. A historical perspective of the role of water facilities in the vehicle design process is presented. The application of water facilities to specific aerodynamic and hydrodynamic flow problems is discussed, and the strengths and limitations of these important experimental tools are emphasized.

  11. Geant4 simulation of the CERN-EU high-energy reference field (CERF) facility.

    PubMed

    Prokopovich, D A; Reinhard, M I; Cornelius, I M; Rosenfeld, A B

    2010-09-01

    The CERN-EU high-energy reference field facility is used for testing and calibrating both active and passive radiation dosemeters for radiation protection applications in space and aviation. Through a combination of a primary particle beam, target and a suitable designed shielding configuration, the facility is able to reproduce the neutron component of the high altitude radiation field relevant to the jet aviation industry. Simulations of the facility using the GEANT4 (GEometry ANd Tracking) toolkit provide an improved understanding of the neutron particle fluence as well as the particle fluence of other radiation components present. The secondary particle fluence as a function of the primary particle fluence incident on the target and the associated dose equivalent rates were determined at the 20 designated irradiation positions available at the facility. Comparisons of the simulated results with previously published simulations obtained using the FLUKA Monte Carlo code, as well as with experimental results of the neutron fluence obtained with a Bonner sphere spectrometer, are made.

  12. Additional experiments on flowability improvements of aviation fuels at low temperatures, volume 2

    NASA Technical Reports Server (NTRS)

    Stockemer, F. J.; Deane, R. L.

    1982-01-01

    An investigation was performed to study flow improver additives and scale-model fuel heating systems for use with aviation hydrocarbon fuel at low temperatures. Test were performed in a facility that simulated the heat transfer and temperature profiles anticipated in wing fuel tanks during flight of long-range commercial aircraft. The results are presented of experiments conducted in a test tank simulating a section of an outer wing integral fuel tank approximately full-scale in height, chilled through heat exchange panels bonded to the upper and lower horizontal surfaces. A separate system heated lubricating oil externally by a controllable electric heater, to transfer heat to fuel pumped from the test tank through an oil-to-fuel heat exchanger, and to recirculate the heated fuel back to the test tank.

  13. VCE testbed program planning and definition study

    NASA Technical Reports Server (NTRS)

    Westmoreland, J. S.; Godston, J.

    1978-01-01

    The flight definition of the Variable Stream Control Engine (VSCE) was updated to reflect design improvements in the two key components: (1) the low emissions duct burner, and (2) the coannular exhaust nozzle. The testbed design was defined and plans for the overall program were formulated. The effect of these improvements was evaluated for performance, emissions, noise, weight, and length. For experimental large scale testing of the duct burner and coannular nozzle, a design definition of the VCE testbed configuration was made. This included selecting the core engine, determining instrumentation requirements, and selecting the test facilities, in addition to defining control system and assembly requirements. Plans for a comprehensive test program to demonstrate the duct burner and nozzle technologies were formulated. The plans include both aeroacoustic and emissions testing.

  14. An outdoor test facility for the large-scale production of microalgae

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, D.A.; Weissman, J.; Goebel, R.

    The goal of the US Department of EnergySolar Energy Research Institute's Aquatic Species Program is to develop the technology base to produce liquid fuels from microalgae. This technology is being initially developed for the desert Southwest. As part of this program an outdoor test facility has been designed and constructed in Roswell, New Mexico. The site has a large existing infrastructure, a suitable climate, and abundant saline groundwater. This facility will be used to evaluate productivity of microalgae strains and conduct large-scale experiments to increase biomass productivity while decreasing production costs. Six 3-m/sup 2/ fiberglass raceways were constructed. Several microalgaemore » strains were screened for growth, one of which had a short-term productivity rate of greater than 50 g dry wt m/sup /minus/2/ d/sup /minus/1/. Two large-scale, 0.1-ha raceways have also been built. These are being used to evaluate the performance trade-offs between low-cost earthen liners and higher cost plastic liners. A series of hydraulic measurements is also being carried out to evaluate future improved pond designs. Future plans include a 0.5-ha pond, which will be built in approximately 2 years to test a scaled-up system. This unique facility will be available to other researchers and industry for studies on microalgae productivity. 6 refs., 9 figs., 1 tab.« less

  15. The ITER Neutral Beam Test Facility towards SPIDER operation

    NASA Astrophysics Data System (ADS)

    Toigo, V.; Dal Bello, S.; Gaio, E.; Luchetta, A.; Pasqualotto, R.; Zaccaria, P.; Bigi, M.; Chitarin, G.; Marcuzzi, D.; Pomaro, N.; Serianni, G.; Agostinetti, P.; Agostini, M.; Antoni, V.; Aprile, D.; Baltador, C.; Barbisan, M.; Battistella, M.; Boldrin, M.; Brombin, M.; Dalla Palma, M.; De Lorenzi, A.; Delogu, R.; De Muri, M.; Fellin, F.; Ferro, A.; Gambetta, G.; Grando, L.; Jain, P.; Maistrello, A.; Manduchi, G.; Marconato, N.; Pavei, M.; Peruzzo, S.; Pilan, N.; Pimazzoni, A.; Piovan, R.; Recchia, M.; Rizzolo, A.; Sartori, E.; Siragusa, M.; Spada, E.; Spagnolo, S.; Spolaore, M.; Taliercio, C.; Valente, M.; Veltri, P.; Zamengo, A.; Zaniol, B.; Zanotto, L.; Zaupa, M.; Boilson, D.; Graceffa, J.; Svensson, L.; Schunke, B.; Decamps, H.; Urbani, M.; Kushwah, M.; Chareyre, J.; Singh, M.; Bonicelli, T.; Agarici, G.; Garbuglia, A.; Masiello, A.; Paolucci, F.; Simon, M.; Bailly-Maitre, L.; Bragulat, E.; Gomez, G.; Gutierrez, D.; Mico, G.; Moreno, J.-F.; Pilard, V.; Chakraborty, A.; Baruah, U.; Rotti, C.; Patel, H.; Nagaraju, M. V.; Singh, N. P.; Patel, A.; Dhola, H.; Raval, B.; Fantz, U.; Fröschle, M.; Heinemann, B.; Kraus, W.; Nocentini, R.; Riedl, R.; Schiesko, L.; Wimmer, C.; Wünderlich, D.; Cavenago, M.; Croci, G.; Gorini, G.; Rebai, M.; Muraro, A.; Tardocchi, M.; Hemsworth, R.

    2017-08-01

    SPIDER is one of two projects of the ITER Neutral Beam Test Facility under construction in Padova, Italy, at the Consorzio RFX premises. It will have a 100 keV beam source with a full-size prototype of the radiofrequency ion source for the ITER neutral beam injector (NBI) and also, similar to the ITER diagnostic neutral beam, it is designed to operate with a pulse length of up to 3600 s, featuring an ITER-like magnetic filter field configuration (for high extraction of negative ions) and caesium oven (for high production of negative ions) layout as well as a wide set of diagnostics. These features will allow a reproduction of the ion source operation in ITER, which cannot be done in any other existing test facility. SPIDER realization is well advanced and the first operation is expected at the beginning of 2018, with the mission of achieving the ITER heating and diagnostic NBI ion source requirements and of improving its performance in terms of reliability and availability. This paper mainly focuses on the preparation of the first SPIDER operations—integration and testing of SPIDER components, completion and implementation of diagnostics and control and formulation of operation and research plan, based on a staged strategy.

  16. Infection prevention and control training and capacity building during the Ebola epidemic in Guinea

    PubMed Central

    Koivogui, Lamine; de Beer, Lindsey; Johnson, Candice Y.; Diaby, Dianka; Ouedraogo, Abdoulaye; Touré, Fatoumata; Bangoura, Fodé Ousmane; Chang, Michelle A.; Chea, Nora; Dotson, Ellen M.; Finlay, Alyssa; Fitter, David; Hamel, Mary J.; Hazim, Carmen; Larzelere, Maribeth; Park, Benjamin J.; Rowe, Alexander K.; Thompson-Paul, Angela M.; Twyman, Anthony; Barry, Moumié; Ntaw, Godlove; Diallo, Alpha Oumar

    2018-01-01

    Background During the 2014–2016 Ebola epidemic in West Africa, a key epidemiological feature was disease transmission within healthcare facilities, indicating a need for infection prevention and control (IPC) training and support. Methods IPC training was provided to frontline healthcare workers (HCW) in healthcare facilities that were not Ebola treatment units, as well as to IPC trainers and IPC supervisors placed in healthcare facilities. Trainings included both didactic and hands-on components, and were assessed using pre-tests, post-tests and practical evaluations. We calculated median percent increase in knowledge. Results From October–December 2014, 20 IPC courses trained 1,625 Guineans: 1,521 HCW, 55 IPC trainers, and 49 IPC supervisors. Median test scores increased 40% (interquartile range [IQR]: 19–86%) among HCW, 15% (IQR: 8–33%) among IPC trainers, and 21% (IQR: 15–30%) among IPC supervisors (all P<0.0001) to post-test scores of 83%, 93%, and 93%, respectively. Conclusions IPC training resulted in clear improvements in knowledge and was feasible in a public health emergency setting. This method of IPC training addressed a high demand among HCW. Valuable lessons were learned to facilitate expansion of IPC training to other prefectures; this model may be considered when responding to other large outbreaks. PMID:29489885

  17. Survey of aircraft icing simulation test facilities in North America

    NASA Technical Reports Server (NTRS)

    Olsen, W.

    1981-01-01

    A survey was made of the aircraft icing simulation facilities in North America: there are 12 wind tunnels, 28 engine test facilities, 6 aircraft tankers and 14 low velocity facilities, that perform aircraft icing tests full or part time. The location and size of the facility, its speed and temperature range, icing cloud parameters, and the technical person to contact are surveyed. Results are presented in tabular form. The capabilities of each facility were estimated by its technical contact person. The adequacy of these facilities for various types of icing tests is discussed.

  18. VIEW LOOKING SOUTH AT THE SATURN V (BLDG. 4550) AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW LOOKING SOUTH AT THE SATURN V (BLDG. 4550) AND SATURN I (BLDG. 4557) STRUCTURAL TEST FACILITIES, SATURN V TEST FACILITY IS IN THE FOREGROUND RIGHT. THE SATURN I TEST FACILITY IS IN THE BACKGROUND CENTER. - Marshall Space Flight Center, Saturn V Dynamic Test Facility, East Test Area, Huntsville, Madison County, AL

  19. Effects of resistance training on body composition and functional capacity among sarcopenic obese residents in long-term care facilities: a preliminary study.

    PubMed

    Chiu, Shu-Ching; Yang, Rong-Sen; Yang, Rea-Jeng; Chang, Shu-Fang

    2018-01-22

    Aging-related loss of muscle and strength with increased adiposity is prevalent among older people in long-term care (LTC) facilities. Studies have shown that people with sarcopenic obesity (SO) are at high risk of declining physical performance. At present, no interventional studies on residents with SO in nursing homes have been conducted in the literature. The objectives of this study include appraising the changes in body composition and physical performance following resistance training among residents with SO in LTC facilities. This study used a quasiexperimental research design. Residents who are 60 years of age or above and have been living a sedentary lifestyle in LTC facilities for the past 3 months will be eligible for inclusion. The intervention group engaged in chair muscle strength training twice a week for 12 weeks, whereas the control group underwent the usual care. The main variables were physical parameters of being lean and fat, the strength of grip and pinch, and a functional independence measure using descriptive analysis, chi-squared test, t-test, and generalized estimating equation for statistical analysis through SPSS. A total of 64 respondents with SO completed the study. After training, total grip strength (p = 0.001) and total pinch strength (p = 0.014) of the intervention group differed significantly from those of the control group. The right grip strength of the intervention group increased by 1.71 kg (p = 0.003) and the left grip strength improved by 1.35 kg (p = 0.028) compared with baseline values. The self-care scores of the intervention group increased by 2.76 points over baseline scores, particularly for the action of dressing oneself. Although grip strength and self-care scores improved more among those in the intervention group, body fat and skeletal muscle percentages did not differ significantly between the groups after training (p > 0.05). Resistance exercises for elderly residents in LTC facilities may play an important role in helping them maintain physical well-being and improve muscle strength. Clinicaltrials.gov, number NCT02912338 . Retrospectively registered on 09/21/2016.

  20. Scaled centrifugal compressor, collector and running gear program

    NASA Technical Reports Server (NTRS)

    Kenehan, J. G.

    1983-01-01

    The Scaled Centrifugal Compressor, Collector and Running gear Program was conducted in support of an overall NASA strategy to improve small-compressor performance, durability, and reliability while reducing initial and life-cycle costs. Accordingly, Garrett designed and provided a test rig, gearbox coupling, and facility collector for a new NASA facility, and provided a scaled model of an existing, high-performance impeller for evaluation scaling effects on aerodynamic performance and for obtaining other performance data. Test-rig shafting was designed to operate smoothly throughout a speed range up to 60,000 rpm. Pressurized components were designed to operate at pressures up to 300 psia and at temperatures to 1000 F. Nonrotating components were designed to provide a margin-of-safety of 0.05 or greater; rotating components, for a margin-of-safety based on allowable yield and ultimate strengths. Design activities were supported by complete design analysis, and the finished hardware was subjected to check-runs to confirm proper operation. The test rig will support a wide range of compressor tests and evaluations.

  1. 40 CFR 792.31 - Testing facility management.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 31 2010-07-01 2010-07-01 true Testing facility management. 792.31... facility management. For each study, testing facility management shall: (a) Designate a study director as... appropriately tested for identity, strength, purity, stability, and uniformity, as applicable. (e) Assure that...

  2. 10th European Zebrafish Meeting 2017, Budapest: Husbandry Workshop Summary.

    PubMed

    Oltová, Jana; Barton, Carrie; Certal, Ana Catarina; Argenton, Francesco; Varga, Zoltán M

    2018-01-02

    A husbandry workshop on July 3, 2017, at the 10th European Zebrafish Meeting in Budapest, Hungary (July 3-July 7, 2017), focused on the standardization, optimization, and streamlining of fish facility procedures. Standardization can be achieved for example by developing novel software and hardware tools, such as a fish facility database for husbandry and environmental facility management (Zebrabase, Oltova), or a hand-held, air-pressurized fish feeder for consistent food distribution (Blowfish, Argenton). Streamlining is achieved when work hours are reduced, as with the standardized fish feeder, or by limiting the number and types of fish diets and observing the effect on animal welfare and performance (Barton). Testing the characteristics of new fish diets and observing whether they produce better experimental outcomes (Certal) optimizes diets and improves fish productivity. Collectively, the workshop presentations emphasized how consistency and harmonization of husbandry procedures within and across aquatic facilities yield reproducible scientific outcomes.

  3. Document control and Conduct of Operations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Collins, S.K.; Meltzer, F.L.

    1993-01-01

    Department of Energy (DOE) Order 5480.19, Conduct of operations, places stringent requirements on a wide range of activities at DOE facilities. These requirements directly affect personnel at the Advanced Test Reactor (ATR), which is located in the Test Reactor Area of the Idaho National Engineering Laboratory and operated for DOE by EG G Idaho, Inc. In order for the ATR to comply with 5480.19, the very personality of the reactor facility's document control unit has had to undergo a major change. The Facility and Administrative Support Unit (FAS) is charged with nudntenance of ATR's controlled ddcuments-diousands of operating and administrativemore » procedures. Prior to the imposition of 5480.19, FAS was content to operate in a clerical support mode, seldom questioning or seeking to improve. This numer of doing business is inappropriate within the framework of DOE 5480.19 and is also at odds with the approach to Total Quality Management (TQM) promulgated by EG G Idaho.To comply with the requirements of 5480.19, FAS has Actively applied TQM principles. Empowered personnel to unprove operations through the establishment of a teatn approach. Begun an automation process that is already paying large dividends in terms of improved procedure accuracy and compliance. A state-of-the-art text retrival system is already in place. We are vigorously pursuing fully automated document tmcidng and document management. This paper describes in detail the steps taken to date, the improvements and the lessons learned. It aLw discusses plans for the future that will enable FAS to support the ATR in inccreasing its responsiveness to the Conduct of Operations Order.« less

  4. Impact of SMS/GPRS Printers in Reducing Time to Early Infant Diagnosis Compared With Routine Result Reporting: A Systematic Review and Meta-Analysis

    PubMed Central

    Markby, Jessica; Boeke, Caroline; Penazzato, Martina; Urick, Brittany; Ghadrshenas, Anisa; Harris, Lindsay; Ford, Nathan; Peter, Trevor

    2017-01-01

    Background: Despite significant gains made toward improving access, early infant diagnosis (EID) testing programs suffer from long test turnaround times that result in substantial loss to follow-up and mortality associated with delays in antiretroviral therapy initiation. These delays in treatment initiation are particularly impactful because of significant HIV-related infant mortality observed by 2–3 months of age. Short message service (SMS) and general packet radio service (GPRS) printers allow test results to be transmitted immediately to health care facilities on completion of testing in the laboratory. Methods: We conducted a systematic review and meta-analysis to assess the benefit of using SMS/GPRS printers to increase the efficiency of EID test result delivery compared with traditional courier paper–based results delivery methods. Results: We identified 11 studies contributing data for over 16,000 patients from East and Southern Africa. The test turnaround time from specimen collection to result received at the health care facility with courier paper–based methods was 68.0 days (n = 6835), whereas the test turnaround time with SMS/GPRS printers was 51.1 days (n = 6711), resulting in a 2.5-week (25%) reduction in the turnaround time. Conclusions: Courier paper–based EID test result delivery methods are estimated to add 2.5 weeks to EID test turnaround times in low resource settings and increase the risk that infants receive test results during or after the early peak of infant mortality. SMS/GPRS result delivery to health care facility printers significantly reduced test turnaround time and may reduce this risk. SMS/GPRS printers should be considered for expedited delivery of EID and other centralized laboratory test results. PMID:28825941

  5. Evaluation of Additive Manufacturing for Composite Part Molds

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Duty, Chad E.; Springfield, Robert M.

    2015-02-01

    The ORNL Manufacturing Demonstration Facility (MDF) collaborated with Tru-Design to test the quality and durability of molds used for making fiber reinforced composites using additive manufacturing. The partners developed surface treatment techniques including epoxy coatings and machining to improve the quality of the surface finish. Test samples made using the printed and surface finished molds demonstrated life spans suitable for one-of-a-kind and low-volume applications, meeting the project objective.

  6. Comparison of flight results with digital simulation for a digital electronic engine control in an F-15 airplane

    NASA Technical Reports Server (NTRS)

    Myers, L. P.; Burcham, F. W., Jr.

    1983-01-01

    Substantial benefits of a full authority digital electronic engine control on an air breathing engine were demonstrated repeatedly in simulation studies, ground engine tests, and engine altitude test facilities. A digital engine electronic control system showed improvements in efficiency, performance, and operation. An additional benefit of full authority digital controls is the capability of detecting and correcting failures and providing engine health diagnostics.

  7. What is the cost of providing outpatient HIV counseling and testing and antiretroviral therapy services in selected public health facilities in Nigeria?

    PubMed

    Aliyu, Husaina Bello; Chuku, Nkata Nwani; Kola-Jebutu, Abimbola; Abubakar, Zubaida; Torpey, Kwasi; Chabikuli, Otto Nzapfurundi

    2012-10-01

    Limited data on actual cost of providing HIV/AIDS services in Nigeria makes planning difficult. A study was conducted in 9 public health facilities supported by the Global HIV/AIDS Initiative Nigeria. The objective was to determine the cost of outpatient HIV Testing and Counseling (HTC) and antiretroviral therapy (ART) services per patient. Two tertiary and 7 secondary facilities were purposively selected across the six geopolitical regions. Facilities were distributed in urban and rural settings. Utilization and cost data for a 12-month period (January to December 2010) were analyzed. Cost elements included consumables, human resources, infrastructure, trainings, facility management, and Global HIV/AIDS Initiative Nigeria technical support. Total costs were apportioned based on percentage utilization by services, and unit costs were derived by dividing resource inputs by service outputs. Data were analyzed using Microsoft Excel 2003. A sensitivity analysis was also conducted for key assumptions. Mean costs for HTC and ART were US $7.4 and US $209.0, respectively. Costs were higher in Northern facilities (US $6.9, US $250.8), compared with Southern ones (US $6.7, US $194.7); and in tertiary facilities ($18.5, $338.4), compared with secondary ones ($6.3, $204.9). Major cost drivers for HTC and ART were human resources--ranging from 62% to 50%, and ARV drugs--ranging from 54% to 31%, respectively. Governments' ability to negotiate lower priced antiretroviral drugs will be central to reducing the cost of ART. Additionally, use of lower cadre staff to provide HTC will reduce costs and improves efficiency.

  8. Development of improved high temperature seals and lubricants for downhole motors in geothermal applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    De La Fosse, P.H.; Black, A.D.; DiBona, B.G.

    1983-01-01

    A major limitation of downhole mud motors for geothermal drilling, as well as straight-hole oil and gas drilling, is the bearing section. Reduced bearing life results from the inability to seal a lubricant in the bearing pack. A reliable rotary seal will extend the bearing life and will allow high pressure drops across the bit for improved bottomhole cleaning and increased drilling rate. This paper summarizes the results of a six-year program funded by the U.S. Department of Energy/Division of Geothermal Energy to develop a sealed bearing pack for use with downhole motors in geothermal applications. Descriptions of the Sealmore » Test Machine, Lubricant Test Machine and Bearing Pack Test Facility are presented. Summaries of all seal tests, lubricant tests and bearing pack tests are provided; and a comprehensive program bibliography is presented.« less

  9. Antenna Test Facility (ATF): User Test Planning Guide

    NASA Technical Reports Server (NTRS)

    Lin, Greg

    2011-01-01

    Test process, milestones and inputs are unknowns to first-time users of the ATF. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  10. Radiant Heat Test Facility (RHTF): User Test Planning Guide

    NASA Technical Reports Server (NTRS)

    DelPapa, Steven

    2011-01-01

    Test process, milestones and inputs are unknowns to first-time users of the RHTF. The User Test Planning Guide aids in establishing expectations for both NASA and non- NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  11. Automation and Upgrade of Thermal System for Large 38-Year-Young Test Facility

    NASA Technical Reports Server (NTRS)

    Webb, Andrew T.; Powers, Edward I. (Technical Monitor)

    2000-01-01

    The Goddard Space Flight Center's Space Environment Simulator (SES) facility has been improved by the upgrade of its thermal control hardware and software. This paper describes the preliminary design process, funding constraints, and the proposed enhancements as well as the installation details, the testing difficulties, and the overall benefits realized from this upgrade. The preliminary design process was discussed in a paper presented in October 1996 and will be recapped in this paper to provide background and comparison to actual product. Structuring the procurement process to match the funding constraints allowed Goddard to enhance its capabilities in an environment of reduced budgets. The installation of the new system into a location that has been occupied for over 38 years was one of the driving design factors for the size of the equipment. The installation was completed on time and under budget. The tuning of the automatic sequences for the new thermal system to the existing shroud system required more time and ultimately presented some setbacks to the vendor and the final completion of the system. However, the end product and its benefits to Goddard's thermal vacuum test portfolio will carry the usefulness of this facility well into the next century.

  12. Automation and Upgrade of Thermal System for Large 38-Year Young Test Facility

    NASA Technical Reports Server (NTRS)

    Webb, Andrew

    2000-01-01

    The Goddard Space Flight Center's Space Environment Simulator (SES) facility has been improved by the upgrade of its thermal control hardware and software. This paper describes the preliminary design process, funding constraints, and the proposed enhancements as well as the installation details, the testing difficulties, and the overall benefits realized from this upgrade. The preliminary design process was discussed in a paper presented in October 1996 and will be recapped in this paper to provide background and comparison to actual product. Structuring the procurement process to match the funding constraints allowed Goddard to enhance its capabilities in an environment of reduced budgets. The installation of the new system into a location that has been occupied for over 38-years was one of the driving design factors for the size of the equipment. The installation was completed on-time and under budget. The tuning of the automatic sequences for the new thermal system to the existing shroud system required more time and ultimately presented some setbacks to the vendor and the final completion of the system. However, the end product and its benefits to Goddard's thermal vacuum test portfolio will carry the usefulness of this facility well into the next century.

  13. Facility-Level Factors Influencing Retention of Patients in HIV Care in East Africa.

    PubMed

    Rachlis, Beth; Bakoyannis, Giorgos; Easterbrook, Philippa; Genberg, Becky; Braithwaite, Ronald Scott; Cohen, Craig R; Bukusi, Elizabeth A; Kambugu, Andrew; Bwana, Mwebesa Bosco; Somi, Geoffrey R; Geng, Elvin H; Musick, Beverly; Yiannoutsos, Constantin T; Wools-Kaloustian, Kara; Braitstein, Paula

    2016-01-01

    Losses to follow-up (LTFU) remain an important programmatic challenge. While numerous patient-level factors have been associated with LTFU, less is known about facility-level factors. Data from the East African International epidemiologic Databases to Evaluate AIDS (EA-IeDEA) Consortium was used to identify facility-level factors associated with LTFU in Kenya, Tanzania and Uganda. Patients were defined as LTFU if they had no visit within 12 months of the study endpoint for pre-ART patients or 6 months for patients on ART. Adjusting for patient factors, shared frailty proportional hazard models were used to identify the facility-level factors associated with LTFU for the pre- and post-ART periods. Data from 77,362 patients and 29 facilities were analyzed. Median age at enrolment was 36.0 years (Interquartile Range: 30.1, 43.1), 63.9% were women and 58.3% initiated ART. Rates (95% Confidence Interval) of LTFU were 25.1 (24.7-25.6) and 16.7 (16.3-17.2) per 100 person-years in the pre-ART and post-ART periods, respectively. Facility-level factors associated with increased LTFU included secondary-level care, HIV RNA PCR turnaround time >14 days, and no onsite availability of CD4 testing. Increased LTFU was also observed when no nutritional supplements were provided (pre-ART only), when TB patients were treated within the HIV program (pre-ART only), and when the facility was open ≤4 mornings per week (ART only). Our findings suggest that facility-based strategies such as point of care laboratory testing and separate clinic spaces for TB patients may improve retention.

  14. Materials Test Laboratory activities at the NASA-Johnson Space Center White Sands Test Facility (WSTF)

    NASA Technical Reports Server (NTRS)

    Stradling, J.; Pippen, D. L.

    1985-01-01

    The NASA Johnson Space Center White Sands Test Facility (WSTF) performs aerospace materials testing and evaluation. Established in 1963, the facility grew from a NASA site dedicated to the development of space engines for the Apollo project to a major test facility. In addition to propulsion tests, it tests materials and components, aerospace fluids, and metals and alloys in simulated space environments.

  15. 40 CFR 160.31 - Testing facility management.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Testing facility management. 160.31... GOOD LABORATORY PRACTICE STANDARDS Organization and Personnel § 160.31 Testing facility management. For each study, testing facility management shall: (a) Designate a study director as described in § 160.33...

  16. [Security Management in Clinical Laboratory Departments and Facilities: Current Status and Issues].

    PubMed

    Ishida, Haku; Nakamura, Junji; Yoshida, Hiroshi; Koike, Masaru; Inoue, Yuji

    2014-11-01

    We conducted a questionnaire survey regarding the current activities for protecting patients' privacy and the security of information systems (IS) related to the clinical laboratory departments of university hospitals, certified training facilities for clinical laboratories, and general hospitals in Yamaguchi Prefecture. The response rate was 47% from 215 medical institutions, including three commercial clinical laboratory centers. The results showed that there were some differences in management activities among facilities with respect to continuing education, the documentation or regulation of operational management for paper records, electronic information, remaining samples, genetic testing, and laboratory information for secondary use. They were suggested to be caused by differences in functions between university and general hospitals, differences in the scale of hospitals, or whether or not hospitals have received accreditation or ISO 15189. Regarding the IS, although the majority of facilities had sufficiently employed the access control to IS, there was some room for improvement in the management of special cases such as VIPs and patients with HIV infection. Furthermore, there were issues regarding the login method for computers shared by multiple staff, the showing of the names of personnel in charge of reports, and the risks associated with direct connections to systems and the Internet and the use of portable media such as USB memory sticks. These results indicated that further efforts are necessary for each facility to continue self-assessment and make improvements.

  17. Development and application of dynamic simulations of a subsonic wind tunnel

    NASA Technical Reports Server (NTRS)

    Szuch, J. R.; Cole, G. L.; Seidel, R. C.; Arpasi, D. J.

    1986-01-01

    Efforts are currently underway at NASA Lewis to improve and expand ground test facilities and to develop supporting technologies to meet anticipated aeropropulsion research needs. Many of these efforts have been focused on a proposed rehabilitation of the Altitude Wind Tunnel (AWT). In order to insure a technically sound design, an AWT modeling program (both analytical and physical) was initiated to provide input to the AWT final design process. This paper describes the approach taken to develop analytical, dynamic computer simulations of the AWT, and the use of these simulations as test-beds for: (1) predicting the dynamic response characteristics of the AWT, and (2) evaluating proposed AWT control concepts. Plans for developing a portable, real-time simulator for the AWT facility are also described.

  18. Can psychiatric liaison reduce neuroleptic use and reduce health service utilization for dementia patients residing in care facilities.

    PubMed

    Ballard, Clive; Powell, Ian; James, Ian; Reichelt, Katharina; Myint, Pat; Potkins, Dawn; Bannister, Carol; Lana, Marisa; Howard, Robert; O'Brien, John; Swann, Alan; Robinson, Damian; Shrimanker, Jay; Barber, Robert

    2002-02-01

    The quality of care and overuse of neuroleptic medication in care environments are major issues in the care of elderly people with dementia. The quality of care (Dementia Care Mapping), the severity of Behavioural and Psychological Symptoms (BPSD--Neuropsychiatric Inventory), expressive language skills (Sheffield Acquired Language Disorder scale), service utilization and use of neuroleptic drugs was compared over 9 months between six care facilities receiving a psychiatric liaison service and three facilities receiving the usual clinical support, using a single blind design. There was a significant reduction in neuroleptic usage in the facilities receiving the liaison service (McNemar test p<0.0001), but not amongst those receiving standard clinical support (McNemar test p=0.07). There were also significantly less GP contacts (t=3.9 p=0.0001) for residents in the facilities receiving the liaison service, and a three fold reduction in psychiatric in-patient bed usage (Bed days per person 0.6 vs. 1.5). Residents in care facilities receiving the liaison service experienced significantly less deterioration in expressive language skills (t=2.2 p=0.03), but there were no significant differences in BPSD or wellbeing. A resource efficient psychiatric liaison service can reduce neuroleptic drug use and reduce some aspects of health service utilization; but a more extensive intervention is probably required to improve the overall quality of care. Copyright 2002 John Wiley & Sons, Ltd.

  19. Facility-level association of preoperative stress testing and postoperative adverse cardiac events.

    PubMed

    Valle, Javier A; Graham, Laura; Thiruvoipati, Thejasvi; Grunwald, Gary; Armstrong, Ehrin J; Maddox, Thomas M; Hawn, Mary T; Bradley, Steven M

    2018-06-22

    Despite limited indications, preoperative stress testing is often used prior to non-cardiac surgery. Patient-level analyses of stress testing and outcomes are limited by case mix and selection bias. Therefore, we sought to describe facility-level rates of preoperative stress testing for non-cardiac surgery, and to determine the association between facility-level preoperative stress testing and postoperative major adverse cardiac events (MACE). We identified patients undergoing non-cardiac surgery within 2 years of percutaneous coronary intervention in the Veterans Affairs (VA) Health Care System, from 2004 to 2011, facility-level rates of preoperative stress testing and postoperative MACE (death, myocardial infarction (MI) or revascularisation within 30 days). We determined risk-standardised facility-level rates of stress testing and postoperative MACE, and the relationship between facility-level preoperative stress testing and postoperative MACE. Among 29 937 patients undergoing non-cardiac surgery at 131 VA facilities, the median facility rate of preoperative stress testing was 13.2% (IQR 9.7%-15.9%; range 6.0%-21.5%), and 30-day postoperative MACE was 4.0% (IQR 2.4%-5.4%). After risk standardisation, the median facility-level rate of stress testing was 12.7% (IQR 8.4%-17.4%) and postoperative MACE was 3.8% (IQR 2.3%-5.6%). There was no correlation between risk-standardised stress testing and composite MACE at the facility level (r=0.022, p=0.81), or with individual outcomes of death, MI or revascularisation. In a national cohort of veterans undergoing non-cardiac surgery, we observed substantial variation in facility-level rates of preoperative stress testing. Facilities with higher rates of preoperative stress testing were not associated with better postoperative outcomes. These findings suggest an opportunity to reduce variation in preoperative stress testing without sacrificing patient outcomes. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  20. The BetterBirth Program: Pursuing Effective Adoption and Sustained Use of the WHO Safe Childbirth Checklist Through Coaching-Based Implementation in Uttar Pradesh, India.

    PubMed

    Kara, Nabihah; Firestone, Rebecca; Kalita, Tapan; Gawande, Atul A; Kumar, Vishwajeet; Kodkany, Bhala; Saurastri, Rajiv; Pratap Singh, Vinay; Maji, Pinki; Karlage, Ami; Hirschhorn, Lisa R; Semrau, Katherine Ea

    2017-06-27

    Shifting childbirth into facilities has not improved health outcomes for mothers and newborns as significantly as hoped. Improving the quality and safety of care provided during facility-based childbirth requires helping providers to adhere to essential birth practices-evidence-based behaviors that reduce harm to and save lives of mothers and newborns. To achieve this goal, we developed the BetterBirth Program, which we tested in a matched-pair, cluster-randomized controlled trial in Uttar Pradesh, India. The goal of this intervention was to improve adoption and sustained use of the World Health Organization Safe Childbirth Checklist (SCC), an organized collection of 28 essential birth practices that are known to improve the quality of facility-based childbirth care. Here, we describe the BetterBirth Program in detail, including its 4 main features: implementation tools, an implementation strategy of coaching, an implementation pathway (Engage-Launch-Support), and a sustainability plan. This coaching-based implementation of the SCC motivates and empowers care providers to identify, understand, and resolve the barriers they face in using the SCC with the resources already available. We describe important lessons learned from our experience with the BetterBirth Program as it was tested in the BetterBirth Trial. For example, the emphasis on relationship building and respect led to trust between coaches and birth attendants and helped influence change. In addition, the cloud-based data collection and feedback system proved a valuable asset in the coaching process. More research on coaching-based interventions is required to refine our understanding of what works best to improve quality and safety of care in various settings.Note: At the time of publication of this article, the results of evaluation of the impact of the BetterBirth Program were pending publication in another journal. After the impact findings have been published, we will update this article with a reference to the impact findings. © Kara et al.

  1. Development of a Quality of Meals and Meal Service Set of Indicators for Residential Facilities for Elderly.

    PubMed

    Van Damme, N; Buijck, B; Van Hecke, A; Verhaeghe, S; Goossens, E; Beeckman, D

    2016-01-01

    To develop a content validated set of indicators to evaluate the quality of meals and meal service in residential facilities for elderly. Inadequate food intake is an important risk factor for malnutrition in residential facilities for elderly. Through better meeting the needs and preferences of residents and optimization of meals and meal service, residents' food intake can improve. No indicators were available which could help to guide strategies to improve the quality of meals and meal service. The indicator set was developed according to the Indicator Development Manual of the Dutch Institute for Health Care Improvement (CBO). The working group consisted of three nurse researchers and one expert in gastrology and had expertise in elderly care, malnutrition, indicator development, and food quality. A preliminary list of potential indicators was compiled using the literature and the working group's expertise. Criteria necessary to measure the indicator in practice were developed for each potential indicator. In a double Delphi procedure, the list of potential indicators and respective criteria were analyzed for content validity, using a multidisciplinary expert panel of 11 experts in elderly meal care. A preliminary list of 20 quality indicators, including 45 criteria, was submitted to the expert panel in a double Delphi procedure. After the second Delphi round, 13 indicators and 25 criteria were accepted as having content validity. The content validity index (CVI) ranged from 0.83 to 1. The indicator set consisted of six structural, four result, and three outcome indicators covering the quality domains food, service and choice, as well as nutritional screening. The criteria measure diverse aspects of meal care which are part of the responsibility of kitchen staff and health care professionals. The 'quality of meals and meal service' set of indicators is a resource to map meal quality in residential facilities for elderly. As soon as feasibility tests in practice are completed, the indicator set can be used to guide meal and meal service quality improvement projects in collaboration with kitchen staff and health care professionals. These improvement projects will help to improve food intake and reduce the risk of malnutrition among elders living in residential facilities.

  2. Influence of the magnetic field profile on ITER conductor testing

    NASA Astrophysics Data System (ADS)

    Nijhuis, A.; Ilyin, Y.; ten Kate, H. H. J.

    2006-08-01

    We performed simulations with the numerical CUDI-CICC code on a typical short ITER (International Thermonuclear Experimental Reactor) conductor test sample of dual leg configuration, as usually tested in the SULTAN test facility, and made a comparison with the new EFDA-Dipole test facility offering a larger applied DC field region. The new EFDA-Dipole test facility, designed for short sample testing of conductors for ITER, has a homogeneous high field region of 1.2 m, while in the SULTAN facility this region is three times shorter. The inevitable non-uniformity of the current distribution in the cable, introduced by the joints at both ends, has a degrading effect on voltage-current (VI) and voltage-temperature (VT) characteristics, particularly for these short samples. This can easily result in an underestimation or overestimation of the actual conductor performance. A longer applied DC high field region along a conductor suppresses the current non-uniformity by increasing the overall longitudinal cable electric field when reaching the current sharing mode. The numerical interpretation study presented here gives a quantitative analysis for a relevant practical case of a test of a short sample poloidal field coil insert (PFCI) conductor in SULTAN. The simulation includes the results of current distribution analysis from self-field measurements with Hall sensor arrays, current sharing measurements and inter-petal resistance measurements. The outcome of the simulations confirms that the current uniformity improves with a longer high field region but the 'measured' VI transition is barely affected, though the local peak voltages become somewhat suppressed. It appears that the location of the high field region and voltage taps has practically no influence on the VI curve as long as the transverse voltage components are adequately cancelled. In particular, for a thin conduit wall, the voltage taps should be connected to the conduit in the form of an (open) azimuthally soldered wire, averaging the transverse conduit surface potentials initiated in the joints.

  3. Summary of aluminum nitrate tests at the F/H-ETF

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCabe, D.J.; Wiggins, A.W.

    1992-05-01

    Biofouling of the Norton ceramic filters in the F/H Effluent Treatment Facility (ETF) has been minimized by bacterial control strategies on the influent streams. However, enough bacteria still exists in the routine influent to impact the filter performance. One method of remediating biofouling in routine influent, initially observed in laboratory tests on simulant solutions, involves addition of aluminum nitrate to the influent wastewater. Tests on actual feed at the ETF using aluminum nitrate showed significantly improved performance, with increases in filter permeability of up to four-fold compared to the baseline case. These improvements were only realized after modifications to themore » pH adjustment system were completed which minimized upsets in the pH of the feed solutions.« less

  4. Methods for evaluating temporal trends in noise exposure

    PubMed Central

    Neitzel, RL; Galusha, D; Dixon-Ernst, C; Rabinowitz, PM

    2014-01-01

    Objective Hearing conservation programs have been mandatory in many US industries since 1983. Since then, three program elements (audiometric testing, hearing protection, and training) have been the focus of much research. By comparison, little has been done on noise exposure evaluation. Design and study sample Utilizing a large dataset (>10,000 measurements over 20 years) from eight facilities operated by a multinational aluminum manufacturing company, we evaluated several approaches to assessing temporal trends in Time Weighted Average (TWA) exposures and the fraction of measurements exceeding 85 dBA by facility, by exposure group within facility, and by individual worker within facility. Results Overall, exposures declined across locations over the study period. Several facilities demonstrated substantial reductions in exposure, and the results of mean noise levels and exceedance fractions generally showed good agreement. The results of analyses at the individual level diverged with analyses by facility and exposure group within facility, suggesting that individual-level analyses, while challenging, may provide important information not available from coarser levels of analysis. Conclusions Validated metrics are needed to allow for assessment of temporal trends in noise exposure. Such metrics will improve our ability to characterize, in a standardized manner, efforts to reduce noise-induced hearing loss. PMID:24564696

  5. Methods for evaluating temporal trends in noise exposure.

    PubMed

    Neitzel, R L; Galusha, D; Dixon-Ernst, C; Rabinowitz, P M

    2014-03-01

    Hearing conservation programs have been mandatory in many US industries since 1983. Since then, three program elements (audiometric testing, hearing protection, and training) have been the focus of much research. By comparison, little has been done on noise exposure evaluation. Temporal trends in time weighted average (TWA) exposures and the fraction of measurements exceeding 85 dBA were evaluated by facility, by exposure group within facility, and by individual worker within facility. A large dataset (> 10 000 measurements over 20 years) from eight facilities operated by a multinational aluminum manufacturing company was studied. Overall, exposures declined across locations over the study period. Several facilities demonstrated substantial reductions in exposure, and the results of mean noise levels and exceedance fractions generally showed good agreement. The results of analyses at the individual level diverged with analyses by facility and exposure group within facility, suggesting that individual-level analyses, while challenging, may provide important information not available from coarser levels of analysis. Validated metrics are needed to allow for assessment of temporal trends in noise exposure. Such metrics will improve our ability to characterize, in a standardized manner, efforts to reduce noise-induced hearing loss.

  6. Implementation of repeat HIV testing during pregnancy in Kenya: a qualitative study.

    PubMed

    Rogers, Anna Joy; Weke, Elly; Kwena, Zachary; Bukusi, Elizabeth A; Oyaro, Patrick; Cohen, Craig R; Turan, Janet M

    2016-07-11

    Repeat HIV testing in late pregnancy has the potential to decrease rates of mother-to-child transmission of HIV by identifying mothers who seroconvert after having tested negative for HIV in early pregnancy. Despite being national policy in Kenya, the available data suggest that implementation rates are low. We conducted 20 in-depth semi-structured interviews with healthcare providers and managers to explore barriers and enablers to implementation of repeat HIV testing guidelines for pregnant women. Participants were from the Nyanza region of Kenya and were purposively selected to provide variation in socio-demographics and job characteristics. Interview transcripts were coded and analyzed in Dedoose software using a thematic analysis approach. Four themes were identified a priori using Ferlie and Shortell's Framework for Change and additional themes were allowed to emerge from the data. Participants identified barriers and enablers at the client, provider, facility, and health system levels. Key barriers at the client level from the perspective of providers included late initial presentation to antenatal care and low proportions of women completing the recommended four antenatal visits. Barriers to offering repeat HIV testing for providers included heavy workloads, time limitations, and failing to remember to check for retest eligibility. At the facility level, inconsistent volume of clients and lack of space required for confidential HIV retesting were cited as barriers. Finally, at the health system level, there were challenges relating to the HIV test kit supply chain and the design of nationally standardized antenatal patient registers. Enablers to improving the implementation of repeat HIV testing included client dissemination of the benefits of antenatal care through word-of-mouth, provider cooperation and task shifting, and it was suggested that use of an electronic health record system could provide automatic reminders for retest eligibility. This study highlights some important barriers to improving HIV retesting rates among pregnant women who attend antenatal clinics in the Nyanza region of Kenya at the client, provider, facility, and health system levels. To successfully implement Kenya's national repeat HIV testing guidelines during pregnancy, it is essential that these barriers be addressed and enablers capitalized on through a multi-faceted intervention program.

  7. Feasibility Study of Non-Destructive Techniques to Measure Corrosion in SAVY Containers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davenport, Matthew Nicholas

    2016-07-15

    Stainless Steel SAVY containers are used to transport and store nuclear material. They are prone to interior corrosion in the presence of certain chemicals and a low-oxygen environment. SAVY containers also have relatively thin walls to reduce their weight, making their structural integrity more vulnerable to the effects of corrosion. A nondestructive evaluation system that finds and monitors corrosion within containers in use would improve safety conditions and preclude hazards. Non-destructive testing can determine whether oxidation or corrosion is occurring inside the SAVY containers, and there are a variety of non-destructive testing methods that may be viable. The feasibility studymore » described will objectively decide which method best fits the requirements of the facility and the problem. To improve efficiency, the containers cannot be opened during the non-destructive examination. The chosen technique should also be user-friendly and relatively quick to apply. It must also meet facility requirements regarding wireless technology and maintenance. A feasibility study is an objective search for a new technology or product to solve a particular problem. First, the design, technical, and facility feasibility requirements are chosen and ranked in order of importance. Then each technology considered is given a score based upon a standard ranking system. The technology with the highest total score is deemed the best fit for a certain application.« less

  8. Energy Systems Test Area (ESTA). Power Systems Test Facilities

    NASA Technical Reports Server (NTRS)

    Situ, Cindy H.

    2010-01-01

    This viewgraph presentation provides a detailed description of the Johnson Space Center's Power Systems Facility located in the Energy Systems Test Area (ESTA). Facilities and the resources used to support power and battery systems testing are also shown. The contents include: 1) Power Testing; 2) Power Test Equipment Capabilities Summary; 3) Source/Load; 4) Battery Facilities; 5) Battery Test Equipment Capabilities Summary; 6) Battery Testing; 7) Performance Test Equipment; 8) Battery Test Environments; 9) Battery Abuse Chambers; 10) Battery Abuse Capabilities; and 11) Battery Test Area Resources.

  9. New NREL Research Facility Slashes Energy Use by 66 Percent

    Science.gov Websites

    Thermal Test Facility, which serves as a showcase of energy-saving features and the home of NREL's cutting technologies now being developed at the Thermal Test Facility will help us reach this goal." The facility energy-efficient building design, NREL's Thermal Test Facility houses sophisticated equipment for

  10. SSPF Operational Upgrades

    NASA Image and Video Library

    2016-11-15

    During a ribbon cutting ceremony in the high bay of the Space Station Processing Facility at NASA's Kennedy Space Center in Florida, center director Bob Cabana, far left, is joined by Bill Dowdell, Kennedy's International Space Station technical director, Josephine Burnett, director of Exploration Research and Technology, Andy Allen, Jacobs vice president and general manager and Test and Operations Support Contract program manager, and Jeff McAlear, Jacobs director of Processing Services. The event celebrated completion of facility modifications to improve processing and free up zones tailored to a variety of needs supporting a robust assortment of space-bound hardware including NASA programs and commercial space companies.

  11. Application of advanced coating techniques to rocket engine components

    NASA Technical Reports Server (NTRS)

    Verma, S. K.

    1988-01-01

    The materials problem in the space shuttle main engine (SSME) is reviewed. Potential coatings and the method of their application for improved life of SSME components are discussed. A number of advanced coatings for turbine blade components and disks are being developed and tested in a multispecimen thermal fatigue fluidized bed facility at IIT Research Institute. This facility is capable of producing severe strains of the degree present in blades and disk components of the SSME. The potential coating systems and current efforts at IITRI being taken for life extension of the SSME components are summarized.

  12. An overview of HyFIE Technical Research Project: cross-testing in main European hypersonic wind tunnels on EXPERT body

    NASA Astrophysics Data System (ADS)

    Brazier, Jean-Philippe; Martinez Schramm, Jan; Paris, Sébastien; Gawehn, Thomas; Reimann, Bodo

    2016-09-01

    HyFIE project aimed at improving the measurement techniques in hypersonic wind tunnels and comparing the experimental data provided by four major European facilities: DLR HEG and H2K, ONERA F4 and VKI Longshot. A common geometry of EXPERT body was chosen and four different models were used. A large amount of experimental data was collected and compared with the results of numerical simulations. Collapsing all the measured values showed a good agreement between the different facilities, as well as between experimental and computed data.

  13. Statistical models for incorporating data from routine HIV testing of pregnant women at antenatal clinics into HIV/AIDS epidemic estimates.

    PubMed

    Sheng, Ben; Marsh, Kimberly; Slavkovic, Aleksandra B; Gregson, Simon; Eaton, Jeffrey W; Bao, Le

    2017-04-01

    HIV prevalence data collected from routine HIV testing of pregnant women at antenatal clinics (ANC-RT) are potentially available from all facilities that offer testing services to pregnant women and can be used to improve estimates of national and subnational HIV prevalence trends. We develop methods to incorporate these new data source into the Joint United Nations Programme on AIDS Estimation and Projection Package in Spectrum 2017. We develop a new statistical model for incorporating ANC-RT HIV prevalence data, aggregated either to the health facility level (site-level) or regionally (census-level), to estimate HIV prevalence alongside existing sources of HIV prevalence data from ANC unlinked anonymous testing (ANC-UAT) and household-based national population surveys. Synthetic data are generated to understand how the availability of ANC-RT data affects the accuracy of various parameter estimates. We estimate HIV prevalence and additional parameters using both ANC-RT and other existing data. Fitting HIV prevalence using synthetic data generally gives precise estimates of the underlying trend and other parameters. More years of ANC-RT data should improve prevalence estimates. More ANC-RT sites and continuation with existing ANC-UAT sites may improve the estimate of calibration between ANC-UAT and ANC-RT sites. We have proposed methods to incorporate ANC-RT data into Spectrum to obtain more precise estimates of prevalence and other measures of the epidemic. Many assumptions about the accuracy, consistency, and representativeness of ANC-RT prevalence underlie the use of these data for monitoring HIV epidemic trends and should be tested as more data become available from national ANC-RT programs.

  14. Statistical Models for Incorporating Data from Routine HIV Testing of Pregnant Women at Antenatal Clinics into HIV/AIDS Epidemic Estimates

    PubMed Central

    Sheng, Ben; Marsh, Kimberly; Slavkovic, Aleksandra B.; Gregson, Simon; Eaton, Jeffrey W.; Bao, Le

    2017-01-01

    Objective HIV prevalence data collected from routine HIV testing of pregnant women at antenatal clinics (ANC-RT) are potentially available from all facilities that offer testing services to pregnant women, and can be used to improve estimates of national and sub-national HIV prevalence trends. We develop methods to incorporate this new data source into the UNAIDS Estimation and Projection Package (EPP) in Spectrum 2017. Methods We develop a new statistical model for incorporating ANC-RT HIV prevalence data, aggregated either to the health facility level (‘site-level’) or regionally (‘census-level’), to estimate HIV prevalence alongside existing sources of HIV prevalence data from ANC unlinked anonymous testing (ANC-UAT) and household-based national population surveys. Synthetic data are generated to understand how the availability of ANC-RT data affects the accuracy of various parameter estimates. Results We estimate HIV prevalence and additional parameters using both ANC-RT and other existing data. Fitting HIV prevalence using synthetic data generally gives precise estimates of the underlying trend and other parameters. More years of ANC-RT data should improve prevalence estimates. More ANC-RT sites and continuation with existing ANC-UAT sites may improve the estimate of calibration between ANC-UAT and ANC-RT sites. Conclusion We have proposed methods to incorporate ANC-RT data into Spectrum to obtain more precise estimates of prevalence and other measures of the epidemic. Many assumptions about the accuracy, consistency, and representativeness of ANC-RT prevalence underlie the use of these data for monitoring HIV epidemic trends, and should be tested as more data become available from national ANC-RT programs. PMID:28296804

  15. Latest update of tests and improvements to US Coast Guard viscous oil pumping system.

    PubMed

    Drieu, Michael D; Nourse, Peter C; MacKay, Ronald; Cooper, David A; Hvidbak, Flemming

    2003-01-01

    Over the past nine years, the US Coast Guard has incorporated the prevention through people (PTP) philosophy as a "human factors" approach to learn how maritime operations can be regulated safer and be more efficient by evaluating training, management policies, operational procedures, and establishing partnerships with the maritime industry. One of the key elements of applying a PTP approach is identifying and incorporating lessons learned from major marine casualties and pollution incidents. Since 1997, the US Coast Guard National Strike Force has responded to three major oil spills involving foreign freight vessels grounding, which included the removal of highly viscous oil using various lightering equipment and systems. An informal workgroup consisting of the US Coast Guard, US Navy Supervisor of Salvage (NAVSUPSALV), and various representatives from oil pollution clean-up companies met at the following facilities: the Chevron Asphalt Facility in Edmonds, WA (September 1999), the Oil and Hazardous Materials Simulated Environmental Test Tank (OHMSETT) testing facility in Leonardo, New Jersey (November 1999 and March 2000), the Alaska Clean Seas (ACS) warehouse annex in Prudhoe Bay, AK (October 2000), and Cenac Towing Company facility in Houma, LA (May 2002). The group shared ideas and techniques, and tested different pumps and hose lengths with viscous oil. It was during the early tests that the first quantitative results showed just how efficient lubricated transport of heavy oil product could be, and broadened the knowledge of such methods to the entire industry. Although this technology had existed for many years in the oil production and handling industry, its use had never been investigated in a laboratory setting with regard to salvage response lightering systems.

  16. 'As a clinician, you are not managing lab results, you are managing the patient': how the enactment of malaria at health facilities in Cameroon compares with new WHO guidelines for the use of malaria tests.

    PubMed

    Chandler, Clare I R; Mangham, Lindsay; Njei, Abanda Ngu; Achonduh, Olivia; Mbacham, Wilfred F; Wiseman, Virginia

    2012-05-01

    In response to widespread overuse of antimalarial drugs, the World Health Organisation changed guidelines in 2010 to restrict the use of antimalarials to parasitologically confirmed malaria cases. Malaria rapid diagnostic tests (RDTs) have been presented as a means to realize the new guidelines, and National Malaria Control Programmes, including that of Cameroon, are developing plans to introduce the tests to replace microscopy or clinical diagnosis at public health facilities across the country. We aimed to understand how malaria tests and antimalarial drugs are currently used as part of social interactions between health workers and patients at public and mission health facilities in Yaoundé and Bamenda and surrounding districts in the Northwest region of Cameroon. In May to June 2010, we held 17 focus group discussions with 146 health workers involved in clinical care from 49 health facilities. Clinicians enacted malaria as a 'juggling' exercise, involving attention to pathophysiology of the patient as well as their desires and medical reputations, utilising tests and medicines for their therapeutic effects as symbols in the process of care. Parasites were rarely mentioned in describing diagnostic decisions. These enactments of malaria contrast with evidence-based guidelines emanating from WHO, which assume the parasite is the central driver of practice. If RDTs are to be taken up in practice, public health practitioners need to pay careful attention to the values and priorities of health workers and patients if they are to work with them to improve diagnosis and treatment of febrile illnesses. Copyright © 2012 Elsevier Ltd. All rights reserved.

  17. 3 CFR 13625 - Executive Order 13625 of August 31, 2012. Improving Access to Mental Health Services for Veterans...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... health services for veterans, service members, and their families. Our public health approach must..., substance abuse treatment facilities, and rural health clinics, to test the effectiveness of community... full understanding of the underlying mechanisms of Post-Traumatic Stress Disorder (PTSD), other mental...

  18. NASA low speed centrifugal compressor

    NASA Technical Reports Server (NTRS)

    Hathaway, Michael D.

    1990-01-01

    The flow characteristics of a low speed centrifugal compressor were examined at NASA Lewis Research Center to improve understanding of the flow in centrifugal compressors, to provide models of various flow phenomena, and to acquire benchmark data for three dimensional viscous flow code validation. The paper describes the objectives, test facilities' instrumentation, and experiment preliminary comparisons.

  19. Evaluating Crude Oil Chemical Dispersion Efficacy In A Flow-Through Wave Tank Under Regular Non-Breaking Wave And Breaking Wave Conditions

    EPA Science Inventory

    Testing dispersant effectiveness under conditions similar to that of the open environment is required for improvements in operational procedures and the formulation of regulatory guidelines. To this end, a novel wave tank facility was fabricated to study the dispersion of crude ...

  20. E-learning education solutions for caregivers in long-term care (LTC) facilities: new possibilities.

    PubMed

    MacDonald, C J; Walton, R

    2007-11-01

    Online learning (referred to as e-learning throughout this article) has proved to be a useful tool for delivering accessible and convenient education to busy clinical healthcare workers. The ABS Management Company specifically designed a program to provide nurses and caregivers with the necessary knowledge and skills to improve the quality of care and the quality of life for the geriatric population in long-term care (LTC) facilities. The purpose of the "Online Solutions: Quality Education for Quality Care in Long-Term Care" program is to use new educational pedagogies and innovative ways to conceptualise and deliver healthcare education to meet the complex issues and concerns of caregivers in LTC facilities. During the one-year period that data were collected for this study, 881 caregivers completed the eight (one-hour) modules in the program. Of these, 753 (85%) completed the optional assessment (both the pre and post tests) for one or more of the eight modules. Therefore, of the 881 employees who reviewed all eight modules (881x8 = 7048 modules), 1046 modules (15%) had both pre-post test data upon which to build the analysis. Information from the evaluation revealed learner improvement in pre-post test scores in excess of 10%, suggesting an increase in new and relevant skills and knowledge related to abuse and neglect, elopement, infection control, nutrition and hydration, pressure ulcers, provision of basic care and restraints. Moreover, the data indicated a reduction in the use of restraints and occurrence of pressure ulcers, suggesting that learners applied new knowledge and skills in the workplace. Finally, staff turnover rates decreased more than 20% suggesting greater job satisfaction after participating in the program. The research findings point to an urgent and unmet need to provide more accessible just-in-time, just-for-you education programs for caregivers in LTC facilities to ensure quality and efficient services to residents and their families.

  1. Vibration and Acoustic Test Facility (VATF): User Test Planning Guide

    NASA Technical Reports Server (NTRS)

    Fantasia, Peter M.

    2011-01-01

    Test process, milestones and inputs are unknowns to first-time users of the VATF. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  2. TRAC analyses for CCTF and SCTF tests and UPTF design/operation. [Cylindrical Core Test Facility; Slab Core Test Facility; Upper Plenum Test Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spore, J.W.; Cappiello, M.W.; Dotson, P.J.

    The analytical support in 1985 for Cylindrical Core Test Facility (CCTF), Slab Core Test Facility (SCTF), and Upper Plenum Test Facility (UPTF) tests involves the posttest analysis of 16 tests that have already been run in the CCTF and the SCTF and the pretest analysis of 3 tests to be performed in the UPTF. Posttest analysis is used to provide insight into the detailed thermal-hydraulic phenomena occurring during the refill and reflood tests performed in CCTF and SCTF. Pretest analysis is used to ensure that the test facility is operated in a manner consistent with the expected behavior of anmore » operating full-scale plant during an accident. To obtain expected behavior of a plant during an accident, two plant loss-of-coolant-accident (LOCA) calculations were performed: a 200% cold-leg-break LOCA calculation for a 2772 MW(t) Babcock and Wilcox plant and a 200% cold-leg-break LOCA calculation for a 3315 MW(t) Westinghouse plant. Detailed results are presented for several CCTF UPI tests and the Westinghouse plant analysis.« less

  3. Development of a EUV Test Facility at the Marshall Space Flight Center

    NASA Technical Reports Server (NTRS)

    West, Edward; Pavelitz, Steve; Kobayashi, Ken; Robinson, Brian; Cirtain, Johnathan; Gaskin, Jessica; Winebarger, Amy

    2011-01-01

    This paper will describe a new EUV test facility that is being developed at the Marshall Space Flight Center (MSFC) to test EUV telescopes. Two flight programs, HiC - high resolution coronal imager (sounding rocket) and SUVI - Solar Ultraviolet Imager (GOES-R), set the requirements for this new facility. This paper will discuss those requirements, the EUV source characteristics, the wavelength resolution that is expected and the vacuum chambers (Stray Light Facility, Xray Calibration Facility and the EUV test chamber) where this facility will be used.

  4. Design Evolution and Verification of the A-3 Chemical Steam Generator

    NASA Technical Reports Server (NTRS)

    Kirchner, Casey K.

    2009-01-01

    Following is an overview of the Chemical Steam Generator system selected to provide vacuum conditions for a new altitude test facility, the A-3 Test Stand at Stennis Space Center (SSC) in Bay St. Louis, MS. A-3 will serve as NASA s primary facility for altitude testing of the J-2X rocket engine, to be used as the primary propulsion device for the upper stages of the Ares launch vehicles. The Chemical Steam Generators (CSGs) will produce vacuum conditions in the test cell through the production and subsequent supersonic ejection of steam into a diffuser downstream of the J-2X engine nozzle exit. The Chemical Steam Generators chosen have a rich heritage of operation at rocket engine altitude test facilities since the days of the Apollo program and are still in use at NASA White Sands Test Facility (WSTF) in New Mexico. The generators at WSTF have been modified to a degree, but are still very close to the heritage design. The intent for the A-3 implementation is to maintain this heritage design as much as possible, making minimal updates only where necessary to substitute for obsolete parts and to increase reliability. Reliability improvements are especially desired because the proposed system will require 27 generators, which is nine times the largest system installed in the 1960s. Improvements were suggested by the original design firm, Reaction Motors, by NASA SSC and NASA WSTF engineers, and by the A-3 test stand design contractor, Jacobs Technology, Inc. (JTI). This paper describes the range of improvements made to the design to date, starting with the heritage generator and the minor modifications made over time at WSTF, to the modernized configuration which will be used at A-3. The paper will discuss NASA s investment in modifications to SSC s E-2 test facility fire a full-scale Chemical Steam Generator in advance of the larger steam system installation at A-3. Risk mitigation testing will be performed in early 2009 at this test facility to verify that the CSGs operate as expected. The generator which will undergo this testing is of the most recent A-3 configuration, and will be instrumented far in excess of what is normally required for operation. The extra data will allow for easier troubleshooting and more complete knowledge of expected generator performance. In addition, the early testing will give SSC personnel experience in operating the CSG systems, which will expedite the process of installation and activation at A-3. Each Chemical Steam Generator is supported by a complement of valves, instruments, and flow control devices, with the entire assembly called a "module." The generators will be installed in groups of three, historically called "units". A module is so called because of its modular ability to be replaced or serviced without disturbing the other two modules installed on the same unit. A module is pictured in Figure 1, shown with its generator secured by white bands in its shipping (vs. installed) configuration. The heritage system at WSTF is composed of a single unit (three generator modules), pictured in Figure 2 as it was installed in 1965. In contrast, A-3 will have nine units operating in parallel to achieve vacuum conditions appropriate for testing the J-2X engine. Each of the combustors operates in two modes and achieves the so-called "full-steam" mode after all three of its stages ignite. Ignition of the first stage is achieved by exciting a spark plug; the second stage and main stage are lit by the flame front of the previous stage. The main stage burns approximately 97% of the total propellant flow and uses the heat energy to vaporize water into superheated steam. While the main stage remains unlit, the combustor is in so-called "idle" mode. In the WSTF system, this idle mode is not optimized for water usage, and does not need to be, as the water is pumped from a large reservoir. The water supply at A-3 will be contained in tanks with finite volume, so water optimization is preferred for the modnized configuration. Multiple solutions for this issue have been proposed, with the leading concept being a change to the operational definition of "idle mode," with the generator running in a lower heat flux condition.

  5. Rocket Motor Microphone Investigation

    NASA Technical Reports Server (NTRS)

    Pilkey, Debbie; Herrera, Eric; Gee, Kent L.; Giraud, Jerom H.; Young, Devin J.

    2010-01-01

    At ATK's facility in Utah, large full-scale solid rocket motors are tested. The largest is a five-segment version of the reusable solid rocket motor, which is for use on the Ares I launch vehicle. As a continuous improvement project, ATK and BYU investigated the use of microphones on these static tests, the vibration and temperature to which the instruments are subjected, and in particular the use of vent tubes and the effects these vents have at low frequencies.

  6. Atmospheric Reentry Materials and Structures Evaluation Facility (ARMSEF). User Test Planning Guide

    NASA Technical Reports Server (NTRS)

    2011-01-01

    Test process, milestones and inputs are unknowns to first-time users of the ARMSEF. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  7. Characterization of fast neutron spectrum in the TRIGA for hardness testing of electronic components

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nelson, George W.

    1986-07-01

    Argonne National Laboratory-West, operated by the University of Chicago, is located near Idaho Falls, ID, on the Idaho National Engineering Laboratory Site. ANL-West performs work in support of the Liquid Metal Fast Breeder Reactor Program (LMFBR) sponsored by the United States Department of Energy. The NRAD reactor is located at the Argonne Site within the Hot Fuel Examination Facility/North, a large hot cell facility where both non-destructive and destructive examinations are performed on highly irradiated reactor fuels and materials in support of the LMFBR program. The NRAD facility utilizes a 250-kW TRIGA reactor and is completely dedicated to neutron radiographymore » and the development of radiography techniques. Criticality was first achieved at the NRAD reactor in October of 1977. Since that time, a number of modifications have been implemented to improve operational efficiency and radiography production. This paper describes the modifications and changes that significantly improved operational efficiency and reliability of the reactor and the essential auxiliary reactor systems. (author)« less

  8. Concept mapping to improve team work, team learning and care of the person with dementia and behavioural and psychological symptoms.

    PubMed

    Aberdeen, Suzanne M; Byrne, Graeme

    2018-04-01

    The incidence of behavioural and psychological symptoms of dementia in residential aged care facilities is high. Effective team work and knowledgeable staff are cited as important facilitators of appropriate care responses to clients with these symptoms, but to achieve this within a resource-poor workplace can be challenging. In the study reported in this paper, concept mapping was trialled to enhance multifocal person-centred assessment and care planning as well as team learning. The outcomes of team concept mapping were evaluated using a quasi-experimental design with pre- and post-testing in 11 selected Australian residential aged care facilities , including two control residential aged care facilities , over a nine-month period. It was demonstrated that use of concept mapping improved team function, measured as effectiveness of care planning, as well as enhancing learning, with increased knowledge of dementia care even amongst staff who were not directly involved with the process. It is suggested that these results may be generalizable to other countries and care settings.

  9. Astronaut Ronald Sega with Wake Shield Facility on test stand at JSC

    NASA Technical Reports Server (NTRS)

    1991-01-01

    The Wake Shield Facility is displayed on a test stand at JSC. Astronaut Ronald M. Sega, mission specialist for STS-60, is seen with the facility during a break in testing in the acoustic and vibration facility at JSC.

  10. Astronaut Ronald Sega with Wake Shield Facility on test stand at JSC

    NASA Image and Video Library

    1991-10-09

    The Wake Shield Facility is displayed on a test stand at JSC. Astronaut Ronald M. Sega, mission specialist for STS-60, is seen with the facility during a break in testing in the acoustic and vibration facility at JSC.

  11. Preparing emergency personnel in dialysis: a just-in-time training program for additional staffing during disasters.

    PubMed

    Stoler, Genevieve B; Johnston, James R; Stevenson, Judy A; Suyama, Joe

    2013-06-01

    There are 341 000 patients in the United States who are dependent on routine dialysis for survival. Recent large-scale disasters have emphasized the importance of disaster preparedness, including supporting dialysis units, for people with chronic disease. Contingency plans for staffing are important for providing continuity of care for a technically challenging procedure such as dialysis. PReparing Emergency Personnel in Dialysis (PREP-D) is a just-in-time training program designed to train individuals having minimum familiarity with the basic steps of dialysis to support routine dialysis staff during a disaster. A 5-module educational program was developed through a collaborative, multidisciplinary effort. A pilot study testing the program was performed using 20 nontechnician dialysis facility employees and 20 clinical-year medical students as subjects. When comparing pretest and posttest scores, the entire study population showed a mean improvement of 28.9%, with dialysis facility employees and medical students showing improvements of 21.8% and 36.4%, respectively (P < .05 for all comparisons). PREP-D participants were able to demonstrate improved tests scores when taught in a just-in-time training format. The knowledge gained by using the PREP-D program during a staffing shortage may allow for continuity of care for critical services such as dialysis during a disaster.

  12. Evaluation of the impact of the 2012 Rhode Island health care worker influenza vaccination regulations: implementation process and vaccination coverage.

    PubMed

    Kim, Hanna; Lindley, Megan C; Dube, Donna; Kalayil, Elizabeth J; Paiva, Kristi A; Raymond, Patricia

    2015-01-01

    In October 2012, the Rhode Island Department of Health (HEALTH) amended its health care worker (HCW) vaccination regulations to require all HCWs to receive annual influenza vaccination or wear a surgical mask during direct patient contact when influenza is widespread. Unvaccinated HCWs failing to wear a mask are subject to a fine and disciplinary action. To describe the implementation of the 2012 Rhode Island HCW influenza vaccination regulations and examine their impact on vaccination coverage. Two data sources were used: (1) a survey of all health care facilities subject to the HCW regulations and (2) HCW influenza vaccination coverage data reported to HEALTH by health care facilities. Descriptive statistics and paired t tests were performed using SAS Release 9.2. For the 2012-2013 influenza season, 271 inpatient and outpatient health care facilities in Rhode Island were subject to the HCW regulations. Increase in HCW influenza vaccination coverage. Of the 271 facilities, 117 facilities completed the survey (43.2%) and 160 facilities reported vaccination data to HEALTH (59.0%). Between the 2011-2012 and 2012-2013 influenza seasons, the proportion of facilities having a masking policy, as required by the revised regulations, increased from 9.4% to 94.0% (P < .001). However, the proportion of facilities implementing Advisory Committee on Immunization Practices-recommended strategies to promote HCW influenza vaccination did not increase. The majority of facilities perceived benefits to collecting HCW influenza vaccination data, including strengthening infection prevention efforts (83.2%) and improving patient and coworker safety (75.2%). Concurrent with the new regulations, influenza vaccination coverage among employee HCWs in Rhode Island increased from 69.7% in the 2011-2012 influenza season to 87.2% in the 2012-2013 season. Rhode Island's experience demonstrates that statewide HCW influenza vaccination requirements incorporating mask wearing and moderate penalties for noncompliance can be effective in improving influenza vaccination coverage among HCWs.

  13. Evaluation of the Impact of the 2012 Rhode Island Health Care Worker Influenza Vaccination Regulations: Implementation Process and Vaccination Coverage

    PubMed Central

    Kim, Hanna; Lindley, Megan C.; Dube, Donna; Kalayil, Elizabeth J.; Paiva, Kristi A.; Raymond, Patricia

    2015-01-01

    Context In October 2012, the Rhode Island Department of Health (HEALTH) amended its health care worker (HCW) vaccination regulations to require all HCWs to receive annual influenza vaccination or wear a surgical mask during direct patient contact when influenza is widespread. Unvaccinated HCWs failing to wear a mask are subject to a fine and disciplinary action. Objective To describe the implementation of the 2012 Rhode Island HCW influenza vaccination regulations and examine their impact on vaccination coverage. Design Two data sources were used: (1) a survey of all health care facilities subject to the HCW regulations and (2) HCW influenza vaccination coverage data reported to HEALTH by health care facilities. Descriptive statistics and paired t tests were performed using SAS Release 9.2. Setting and participants For the 2012-2013 influenza season, 271 inpatient and outpatient health care facilities in Rhode Island were subject to the HCW regulations. Main Outcome Measure Increase in HCW influenza vaccination coverage. Results Of the 271 facilities, 117 facilities completed the survey (43.2%) and 160 facilities reported vaccination data to HEALTH (59.0%). Between the 2011-2012 and 2012-2013 influenza seasons, the proportion of facilities having a masking policy, as required by the revised regulations, increased from 9.4% to 94.0% (P< .001). However, the proportion of facilities implementing Advisory Committee on Immunization Practices–recommended strategies to promote HCW influenza vaccination did not increase. The majority of facilities perceived benefits to collecting HCW influenza vaccination data, including strengthening infection prevention efforts (83.2%) and improving patient and coworker safety (75.2%). Concurrent with the new regulations, influenza vaccination coverage among employee HCWs in Rhode Island increased from 69.7% in the 2011-2012 influenza season to 87.2% in the 2012-2013 season. Conclusion Rhode Island's experience demonstrates that statewide HCW influenza vaccination requirements incorporating mask wearing and moderate penalties for noncompliance can be effective in improving influenza vaccination coverage among HCWs. PMID:25105280

  14. Ground Handling of Batteries at Test and Launch-site Facilities

    NASA Technical Reports Server (NTRS)

    Jeevarajan, Judith A.; Hohl, Alan R.

    2008-01-01

    Ground handling of flight as well as engineering batteries at test facilities and launch-site facilities is a safety critical process. Test equipment interfacing with the batteries should have the required controls to prevent a hazardous failure of the batteries. Test equipment failures should not induce catastrophic failures on the batteries. Transportation requirements for batteries should also be taken into consideration for safe transportation. This viewgraph presentation includes information on the safe handling of batteries for ground processing at test facilities as well as launch-site facilities.

  15. Composite Overwrapped Pressure Vessel (COPV) Stress Rupture Testing

    NASA Technical Reports Server (NTRS)

    Greene, Nathanael J.; Saulsberry, Regor L.; Leifeste, Mark R.; Yoder, Tommy B.; Keddy, Chris P.; Forth, Scott C.; Russell, Rick W.

    2010-01-01

    This paper reports stress rupture testing of Kevlar(TradeMark) composite overwrapped pressure vessels (COPVs) at NASA White Sands Test Facility. This 6-year test program was part of the larger effort to predict and extend the lifetime of flight vessels. Tests were performed to characterize control parameters for stress rupture testing, and vessel life was predicted by statistical modeling. One highly instrumented 102-cm (40-in.) diameter Kevlar(TradeMark) COPV was tested to failure (burst) as a single-point model verification. Significant data were generated that will enhance development of improved NDE methods and predictive modeling techniques, and thus better address stress rupture and other composite durability concerns that affect pressure vessel safety, reliability and mission assurance.

  16. Considerations for setting up an order entry system for nuclear medicine tests.

    PubMed

    Hara, Narihiro; Onoguchi, Masahisa; Nishida, Toshihiko; Honda, Minoru; Houjou, Osamu; Yuhi, Masaru; Takayama, Teruhiko; Ueda, Jun

    2007-12-01

    Integrating the Healthcare Enterprise-Japan (IHE-J) was established in Japan in 2001 and has been working to standardize health information and make it accessible on the basis of the fundamental Integrating Healthcare Enterprise (IHE) specifications. However, because specialized operations are used in nuclear medicine tests, online sharing of patient information and test order information from the order entry system as shown by the scheduled workflow (SWF) is difficult, making information inconsistent throughout the facility and uniform management of patient information impossible. Therefore, we examined the basic design (subsystem design) for order entry systems, which are considered an important aspect of information management for nuclear medicine tests and needs to be consistent with the system used throughout the rest of the facility. There are many items that are required by the subsystem when setting up an order entry system for nuclear medicine tests. Among these items, those that are the most important in the order entry system are constructed using exclusion settings, because of differences in the conditions for using radiopharmaceuticals and contrast agents and appointment frame settings for differences in the imaging method and test items. To establish uniform management of patient information for nuclear medicine tests throughout the facility, it is necessary to develop an order entry system with exclusion settings and appointment frames as standard features. Thereby, integration of health information with the Radiology Information System (RIS) or Picture Archiving Communication System (PACS) based on Digital Imaging Communications in Medicine (DICOM) standards and real-time health care assistance can be attained, achieving the IHE agenda of improving health care service and efficiently sharing information.

  17. Changes in dynamics of accommodation after accommodative facility training in myopes and emmetropes.

    PubMed

    Allen, Peter M; Charman, W Neil; Radhakrishnan, Hema

    2010-05-12

    This study evaluates the effect of accommodative facility training in myopes and emmetropes. Monocular accommodative facility was measured in nine myopes and nine emmetropes for distance and near. Subjective facility was recorded with automated flippers and objective measurements were simultaneously taken with a PowerRefractor. Accommodative facility training (a sequence of 5 min monocular right eye, 5 min monocular left eye, 5 min binocular) was given on three consecutive days and facility was re-assessed on the fifth day. The results showed that training improved the facility rate in both groups. The improvement in facility rates were linked to the time constants and peak velocity of accommodation. Some changes in amplitude seen in emmetropes indicate an improvement in facility rate at the expense of an accurate accommodation response. Copyright 2010 Elsevier Ltd. All rights reserved.

  18. 40 CFR 792.43 - Test system care facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 31 2010-07-01 2010-07-01 true Test system care facilities. 792.43 Section 792.43 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT (CONTINUED) GOOD LABORATORY PRACTICE STANDARDS Facilities § 792.43 Test system care facilities...

  19. Facilities | Hydrogen and Fuel Cells | NREL

    Science.gov Websites

    integration research. Photo of the Hydrogen Infrastructure Testing and Research Facility building, with hydrogen fueling station and fuel cell vehicles. Hydrogen Infrastructure Testing and Research Facility The Hydrogen Infrastructure Testing and Research Facility (HITRF) at the ESIF combines electrolyzers, a

  20. 41 CFR 102-74.310 - What measures must Federal agencies take to improve the utilization of parking facilities?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) FEDERAL MANAGEMENT REGULATION REAL PROPERTY 74-FACILITY MANAGEMENT Facility Management Parking Facilities... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false What measures must Federal agencies take to improve the utilization of parking facilities? 102-74.310 Section 102-74.310...

  1. The NASA landing gear test airplane

    NASA Technical Reports Server (NTRS)

    Carter, John F.; Nagy, Christopher J.

    1995-01-01

    A tire and landing gear test facility has been developed and incorporated into a Convair 990 aircraft. The system can simulate tire vertical load profiles to 250,000 lb, sideslip angles to 15 degrees, and wheel braking on actual runways. Onboard computers control the preprogrammed test profiles through a feedback loop and also record three axis loads, tire slip angle, and tire condition. The aircraft to date has provided tire force and wear data for the Shuttle Orbiter tire on three different runways and at east and west coast landing sites. This report discusses the role of this facility in complementing existing ground tire and landing gear test facilities, and how this facility can simultaneously simulate the vertical load, tire slip, velocity, and surface for an entire aircraft landing. A description is given of the aircraft as well as the test system. An example of a typical test sequence is presented. Data collection and reduction from this facility are discussed, as well as accuracies of calculated parameters. Validation of the facility through ground and flight tests is presented. Tests to date have shown that this facility can operate at remote sites and gather complete data sets of load, slip, and velocity on actual runway surfaces. The ground and flight tests have led to a successful validation of this test facility.

  2. Improving Access to Malaria Rapid Diagnostic Test in Niger State, Nigeria: An Assessment of Implementation up to 2013

    PubMed Central

    Awoleye, Olatunji Joshua; Thron, Chris

    2016-01-01

    Nigeria's 2009–2013 malaria strategic plan adopted WHO diagnosis and treatment guidelines, which include the use of rapid diagnostic tests (RDTs) prior to prescribing treatment with artemisinin combination therapies (ACTs). The current study explores accessibility barriers to the use of RDTs in Niger State and makes recommendations for improving the uptake of RDTs. The study employs literature review, review of data from the Niger State Health Management Information System for January–October 2013, and application of Peters' conceptual framework for assessing access to health services. Data showed that 27 percent of public health facilities (HFs) implemented RDTs, with the aid of donor funds. In these facilities, 77 percent of fever cases presented during the study period were tested with RDTs; 53 percent of fever cases were confirmed cases of malaria, while 60 percent of fever cases were treated. Stockouts of RDTs were a major constraint, and severe fever tended to trigger presumptive treatment. We conclude that although implementation of RDTs led to a reduction in the use of ACTs at HFs, more substantial reduction could be achieved if the state government directed more resources towards the acquisition of RDTs as well as raising the level of awareness of potential users. PMID:27042376

  3. Quality of Voluntary Medical Male Circumcision Services during Scale-Up: A Comparative Process Evaluation in Kenya, South Africa, Tanzania and Zimbabwe

    PubMed Central

    Jennings, Larissa; Bertrand, Jane; Rech, Dino; Harvey, Steven A.; Hatzold, Karin; Samkange, Christopher A.; Omondi Aduda, Dickens S.; Fimbo, Bennett; Cherutich, Peter; Perry, Linnea; Castor, Delivette; Njeuhmeli, Emmanuel

    2014-01-01

    Background The rapid expansion of voluntary medical male circumcision (VMMC) has raised concerns whether health systems can deliver and sustain VMMC according to minimum quality criteria. Methods and Findings A comparative process evaluation was used to examine data from SYMMACS, the Systematic Monitoring of the Voluntary Medical Male Circumcision Scale-Up, among health facilities providing VMMC across two years of program scale-up. Site-level assessments examined the availability of guidelines, supplies and equipment, infection control, and continuity of care services. Direct observation of VMMC surgeries were used to assess care quality. Two sample tests of proportions and t-tests were used to examine differences in the percent of facilities meeting requisite preparedness standards and the mean number of directly-observed surgical tasks performed correctly. Results showed that safe, high quality VMMC can be implemented and sustained at-scale, although substantial variability was observed over time. In some settings, facility preparedness and VMMC service quality improved as the number of VMMC facilities increased. Yet, lapses in high performance and expansion of considerably deficient services were also observed. Surgical tasks had the highest quality scores, with lower performance levels in infection control, pre-operative examinations, and post-operative patient monitoring and counseling. The range of scale-up models used across countries additionally underscored the complexity of delivering high quality VMMC. Conclusions Greater efforts are needed to integrate VMMC scale-up and quality improvement processes in sub-Saharan African settings. Monitoring of service quality, not just adverse events reporting, will be essential in realizing the full health impact of VMMC for HIV prevention. PMID:24801073

  4. An exploratory study of factors that affect the performance and usage of rapid diagnostic tests for malaria in the Limpopo Province, South Africa.

    PubMed

    Moonasar, Devanand; Goga, Ameena Ebrahim; Frean, John; Kruger, Philip; Chandramohan, Daniel

    2007-06-02

    Malaria rapid diagnostic tests (RDTs) are relatively simple to perform and provide results quickly for making treatment decisions. However, the accuracy and application of RDT results depends on several factors such as quality of the RDT, storage, transport and end user performance. A cross sectional survey to explore factors that affect the performance and use of RDTs was conducted in the primary care facilities in South Africa. This study was conducted in three malaria risk sub-districts of the Limpopo Province, in South Africa. Twenty nurses were randomly selected from 17 primary health care facilities, three nurses from hospitals serving the study area and 10 other key informants, representing the managers of the malaria control programmes, routine and research laboratories, were interviewed, using semi-structured questionnaires. There was a high degree of efficiency in ordering and distribution of RDTs, however only 13/20 (65%) of the health facilities had appropriate air-conditioning and monitoring of room temperatures. Sixty percent (12/20) of the nurses did not receive any external training on conducting and interpreting RDT. Fifty percent of nurses (10/20) reported RDT stock-outs. Only 3/20 nurses mentioned that they periodically checked quality of RDT. Fifteen percent of nurses reported giving antimalarial drugs even if the RDT was negative. Storage, quality assurance, end user training and use of RDT results for clinical decision making in primary care facilities in South Africa need to be improved. Further studies of the factors influencing the quality control of RDTs, their performance of RDTs and the ways to improve their use of RDTs are needed.

  5. An exploratory study of factors that affect the performance and usage of rapid diagnostic tests for malaria in the Limpopo Province, South Africa

    PubMed Central

    Moonasar, Devanand; Goga, Ameena Ebrahim; Frean, John; Kruger, Philip; Chandramohan, Daniel

    2007-01-01

    Background Malaria rapid diagnostic tests (RDTs) are relatively simple to perform and provide results quickly for making treatment decisions. However, the accuracy and application of RDT results depends on several factors such as quality of the RDT, storage, transport and end user performance. A cross sectional survey to explore factors that affect the performance and use of RDTs was conducted in the primary care facilities in South Africa. Methods This study was conducted in three malaria risk sub-districts of the Limpopo Province, in South Africa. Twenty nurses were randomly selected from 17 primary health care facilities, three nurses from hospitals serving the study area and 10 other key informants, representing the managers of the malaria control programmes, routine and research laboratories, were interviewed, using semi-structured questionnaires. Results There was a high degree of efficiency in ordering and distribution of RDTs, however only 13/20 (65%) of the health facilities had appropriate air-conditioning and monitoring of room temperatures. Sixty percent (12/20) of the nurses did not receive any external training on conducting and interpreting RDT. Fifty percent of nurses (10/20) reported RDT stock-outs. Only 3/20 nurses mentioned that they periodically checked quality of RDT. Fifteen percent of nurses reported giving antimalarial drugs even if the RDT was negative. Conclusion Storage, quality assurance, end user training and use of RDT results for clinical decision making in primary care facilities in South Africa need to be improved. Further studies of the factors influencing the quality control of RDTs, their performance of RDTs and the ways to improve their use of RDTs are needed. PMID:17543127

  6. Central implementation strategies outperform local ones in improving HIV testing in Veterans Healthcare Administration facilities.

    PubMed

    Goetz, Matthew Bidwell; Hoang, Tuyen; Knapp, Herschel; Burgess, Jane; Fletcher, Michael D; Gifford, Allen L; Asch, Steven M

    2013-10-01

    Pilot data suggest that a multifaceted approach may increase HIV testing rates, but the scalability of this approach and the level of support needed for successful implementation remain unknown. To evaluate the effectiveness of a scaled-up multi-component intervention in increasing the rate of risk-based and routine HIV diagnostic testing in primary care clinics and the impact of differing levels of program support. Three arm, quasi-experimental implementation research study. Veterans Health Administration (VHA) facilities. Persons receiving primary care between June 2009 and September 2011 INTERVENTION: A multimodal program, including a real-time electronic clinical reminder to facilitate HIV testing, provider feedback reports and provider education, was implemented in Central and Local Arm Sites; sites in the Central Arm also received ongoing programmatic support. Control Arm sites had no intervention Frequency of performing HIV testing during the 6 months before and after implementation of a risk-based clinical reminder (phase I) or routine clinical reminder (phase II). The adjusted rate of risk-based testing increased by 0.4 %, 5.6 % and 10.1 % in the Control, Local and Central Arms, respectively (all comparisons, p < 0.01). During phase II, the adjusted rate of routine testing increased by 1.1 %, 6.3 % and 9.2 % in the Control, Local and Central Arms, respectively (all comparisons, p < 0.01). At study end, 70-80 % of patients had been offered an HIV test. Use of clinical reminders, provider feedback, education and social marketing significantly increased the frequency at which HIV testing is offered and performed in VHA facilities. These findings support a multimodal approach toward achieving the goal of having every American know their HIV status as a matter of routine clinical practice.

  7. Correlations of Different Surface Tests: Tire Behavior Math Model for the High Speed Civil Transport (HSCT) and Michelin Tire Properties Tests for Boeing 777

    NASA Technical Reports Server (NTRS)

    Roman, Ivan

    1995-01-01

    In the surfaces correlation study, several different volumetric and drainage measurement techniques for classifying surface texture were evaluated as part of a major study to develop and improve methods for predicting tire friction performance on all types of pavement. The objective of the evaluation was to seek relationships between the different techniques, and to relate those results to surface frictional characteristics. We needed to know how each of the tests could be related to each other. Another of my assigned projects was to make a tire behavior math model for the High Speed Civil Transport (HSCT) using the same methods used for the space shuttle a few years ago. A provided third order equation with two variables was used. This model will also be used for studies with the Boeing 777. Only a few changes will be necessary to adapt it for this other aircraft, which is the newest offered by Boeing. In my final project I was involved with testing the tires for this new aircraft using the Aircraft Landing Dynamics Facility (ALDF) test carriage within the carriage house at LaRC. A 50 inch diameter radial tire manufactured by Michelin Aircraft Tire Corporation had to be tested to double overload of 114,000 pounds. The rated load of each tire is 57,000 pounds, but Boeing required tests assuming failure of a companion tire that could have cost Michelin approximately $12 million to build a facility to provide the required test capability. Here at LaRC, only minimum modifications to the facility were required to perform this specific test.

  8. Implementation research to improve quality of maternal and newborn health care, Malawi.

    PubMed

    Brenner, Stephan; Wilhelm, Danielle; Lohmann, Julia; Kambala, Christabel; Chinkhumba, Jobiba; Muula, Adamson S; De Allegri, Manuela

    2017-07-01

    To evaluate the impact of a performance-based financing scheme on maternal and neonatal health service quality in Malawi. We conducted a non-randomized controlled before and after study to evaluate the effects of district- and facility-level performance incentives for health workers and management teams. We assessed changes in the facilities' essential drug stocks, equipment maintenance and clinical obstetric care processes. Difference-in-difference regression models were used to analyse effects of the scheme on adherence to obstetric care treatment protocols and provision of essential drugs, supplies and equipment. We observed 33 health facilities, 23 intervention facilities and 10 control facilities and 401 pregnant women across four districts. The scheme improved the availability of both functional equipment and essential drug stocks in the intervention facilities. We observed positive effects in respect to drug procurement and clinical care activities at non-intervention facilities, likely in response to improved district management performance. Birth assistants' adherence to clinical protocols improved across all studied facilities as district health managers supervised and coached clinical staff more actively. Despite nation-wide stock-outs and extreme health worker shortages, facilities in the study districts managed to improve maternal and neonatal health service quality by overcoming bottlenecks related to supply procurement, equipment maintenance and clinical performance. To strengthen and reform health management structures, performance-based financing may be a promising approach to sustainable improvements in quality of health care.

  9. User Perceptions of Shared Sanitation among Rural Households in Indonesia and Bangladesh

    PubMed Central

    Nelson, Kali B.; Karver, Jonathan; Kullman, Craig; Graham, Jay P.

    2014-01-01

    Background The practice of sharing sanitation facilities does not meet the current World Health Organization/UNICEF definition for what is considered improved sanitation. Recommendations have been made to categorize shared sanitation as improved sanitation if security, user access, and other conditions can be assured, yet limited data exist on user preferences with respect to shared facilities. Objective This study analyzed user perceptions of shared sanitation facilities in rural households in East Java, Indonesia, and Bangladesh. Methods Cross-sectional studies of 2,087 households in East Java and 3,000 households in Bangladesh were conducted using questionnaires and observational methods. Relative risks were calculated to analyze associations between sanitation access and user perceptions of satisfaction, cleanliness, and safety. Results In East Java, 82.4% of households with private improved sanitation facilities reported feeling satisfied with their place of defecation compared to 68.3% of households with shared improved facilities [RR 1.19, 95% CI 1.09, 1.31]. In Bangladesh, 87.7% of households with private improved facilities reported feeling satisfied compared to 74.5% of households with shared improved facilities [RR 1.15, 95% CI 1.10, 1.20]. In East Java, 79.5% of households who reported a clean latrine also reported feeling satisfied with their place of defecation; only 38.9% of households who reported a dirty latrine also reported feeling satisfied [RR 1.74, 95% CI 1.45, 2.08]. Conclusion Simple distinctions between improved and unimproved sanitation facilities tend to misrepresent the variability observed among households sharing sanitation facilities. Our results suggest that private improved sanitation is consistently preferred over any other sanitation option. An increased number of users appeared to negatively affect toilet cleanliness, and lower levels of cleanliness were associated with lower levels of satisfaction. However, when sanitation facilities were clean and shared by a limited number of households, users of shared facilities often reported feeling both satisfied and safe. PMID:25090096

  10. User perceptions of shared sanitation among rural households in Indonesia and Bangladesh.

    PubMed

    Nelson, Kali B; Karver, Jonathan; Kullman, Craig; Graham, Jay P

    2014-01-01

    The practice of sharing sanitation facilities does not meet the current World Health Organization/UNICEF definition for what is considered improved sanitation. Recommendations have been made to categorize shared sanitation as improved sanitation if security, user access, and other conditions can be assured, yet limited data exist on user preferences with respect to shared facilities. This study analyzed user perceptions of shared sanitation facilities in rural households in East Java, Indonesia, and Bangladesh. Cross-sectional studies of 2,087 households in East Java and 3,000 households in Bangladesh were conducted using questionnaires and observational methods. Relative risks were calculated to analyze associations between sanitation access and user perceptions of satisfaction, cleanliness, and safety. In East Java, 82.4% of households with private improved sanitation facilities reported feeling satisfied with their place of defecation compared to 68.3% of households with shared improved facilities [RR 1.19, 95% CI 1.09, 1.31]. In Bangladesh, 87.7% of households with private improved facilities reported feeling satisfied compared to 74.5% of households with shared improved facilities [RR 1.15, 95% CI 1.10, 1.20]. In East Java, 79.5% of households who reported a clean latrine also reported feeling satisfied with their place of defecation; only 38.9% of households who reported a dirty latrine also reported feeling satisfied [RR 1.74, 95% CI 1.45, 2.08]. Simple distinctions between improved and unimproved sanitation facilities tend to misrepresent the variability observed among households sharing sanitation facilities. Our results suggest that private improved sanitation is consistently preferred over any other sanitation option. An increased number of users appeared to negatively affect toilet cleanliness, and lower levels of cleanliness were associated with lower levels of satisfaction. However, when sanitation facilities were clean and shared by a limited number of households, users of shared facilities often reported feeling both satisfied and safe.

  11. 38. 100,000 POUND STATIC TEST FACILITY: GENERAL VIEW OF TEST ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    38. 100,000 POUND STATIC TEST FACILITY: GENERAL VIEW OF TEST BAY AND EXHAUST PIT, LOOKING WEST - White Sands Missile Range, V-2 Rocket Facilities, Near Headquarters Area, White Sands, Dona Ana County, NM

  12. 37. 100,000 POUND STATIC TEST FACILITY: GENERAL VIEW OF TEST ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    37. 100,000 POUND STATIC TEST FACILITY: GENERAL VIEW OF TEST BAY AND EXHAUST PIT, LOOKING SOUTHWEST - White Sands Missile Range, V-2 Rocket Facilities, Near Headquarters Area, White Sands, Dona Ana County, NM

  13. Improving Quality of Care in Primary Health-Care Facilities in Rural Nigeria

    PubMed Central

    Ugo, Okoli; Ezinne, Eze-Ajoku; Modupe, Oludipe; Nicole, Spieker; Kelechi, Ohiri

    2016-01-01

    Background: Nigeria has a high population density but a weak health-care system. To improve the quality of care, 3 organizations carried out a quality improvement pilot intervention at the primary health-care level in selected rural areas. Objective: To assess the change in quality of care in primary health-care facilities in rural Nigeria following the provision of technical governance support and to document the successes and challenges encountered. Method: A total of 6 states were selected across the 6 geopolitical zones of the country. However, assessments were carried out in 40 facilities in only 5 states. Selection was based on location, coverage, and minimum services offered. The facilities were divided randomly into 2 groups. The treatment group received quality-of-care assessment, continuous feedback, and improvement support, whereas the control group received quality assessment and no other support. Data were collected using the SafeCare Healthcare Standards and managed on the SafeCare Data Management System—AfriDB. Eight core areas were assessed at baseline and end line, and compliance to quality health-care standards was compared. Result: Outcomes from 40 facilities were accepted and analyzed. Overall scores increased in the treatment facilities compared to the control facilities, with strong evidence of improvement (t = 5.28, P = .0004) and 11% average improvement, but no clear pattern of improvement emerged in the control group. Conclusion: The study demonstrated governance support and active community involvement offered potential for quality improvement in primary health-care facilities. PMID:28462280

  14. Improving Quality of Care in Primary Health-Care Facilities in Rural Nigeria: Successes and Challenges.

    PubMed

    Ugo, Okoli; Ezinne, Eze-Ajoku; Modupe, Oludipe; Nicole, Spieker; Winifred, Ekezie; Kelechi, Ohiri

    2016-01-01

    Nigeria has a high population density but a weak health-care system. To improve the quality of care, 3 organizations carried out a quality improvement pilot intervention at the primary health-care level in selected rural areas. To assess the change in quality of care in primary health-care facilities in rural Nigeria following the provision of technical governance support and to document the successes and challenges encountered. A total of 6 states were selected across the 6 geopolitical zones of the country. However, assessments were carried out in 40 facilities in only 5 states. Selection was based on location, coverage, and minimum services offered. The facilities were divided randomly into 2 groups. The treatment group received quality-of-care assessment, continuous feedback, and improvement support, whereas the control group received quality assessment and no other support. Data were collected using the SafeCare Healthcare Standards and managed on the SafeCare Data Management System-AfriDB. Eight core areas were assessed at baseline and end line, and compliance to quality health-care standards was compared. Outcomes from 40 facilities were accepted and analyzed. Overall scores increased in the treatment facilities compared to the control facilities, with strong evidence of improvement ( t = 5.28, P = .0004) and 11% average improvement, but no clear pattern of improvement emerged in the control group. The study demonstrated governance support and active community involvement offered potential for quality improvement in primary health-care facilities.

  15. 78 FR 69433 - Executive Order 13650 Improving Chemical Facility Safety and Security Listening Sessions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-19

    ... Chemical Facility Safety and Security Listening Sessions AGENCY: National Protection and Programs... from stakeholders on issues pertaining to Improving Chemical Facility Safety and Security (Executive... regulations, guidance, and policies; and identifying best practices in chemical facility safety and security...

  16. Nuclear electric propulsion development and qualification facilities

    NASA Technical Reports Server (NTRS)

    Dutt, D. S.; Thomassen, K.; Sovey, J.; Fontana, Mario

    1991-01-01

    This paper summarizes the findings of a Tri-Agency panel consisting of members from the National Aeronautics and Space Administration (NASA), U.S. Department of Energy (DOE), and U.S. Department of Defense (DOD) that were charged with reviewing the status and availability of facilities to test components and subsystems for megawatt-class nuclear electric propulsion (NEP) systems. The facilities required to support development of NEP are available in NASA centers, DOE laboratories, and industry. However, several key facilities require significant and near-term modification in order to perform the testing required to meet a 2014 launch date. For the higher powered Mars cargo and piloted missions, the priority established for facility preparation is: (1) a thruster developmental testing facility, (2) a thruster lifetime testing facility, (3) a dynamic energy conversion development and demonstration facility, and (4) an advanced reactor testing facility (if required to demonstrate an advanced multiwatt power system). Facilities to support development of the power conditioning and heat rejection subsystems are available in industry, federal laboratories, and universities. In addition to the development facilities, a new preflight qualifications and acceptance testing facility will be required to support the deployment of NEP systems for precursor, cargo, or piloted Mars missions. Because the deployment strategy for NEP involves early demonstration missions, the demonstration of the SP-100 power system is needed by the early 2000's.

  17. Carbon Back Sputter Modeling for Hall Thruster Testing

    NASA Technical Reports Server (NTRS)

    Gilland, James H.; Williams, George J.; Burt, Jonathan M.; Yim, John Tamin

    2016-01-01

    Lifetime requirements for electric propulsion devices, including Hall Effect thrusters, are continually increasing, driven in part by NASA's inclusion of this technology in it's exploration architecture. NASA will demonstrate high-power electric propulsion system on the Solar Electric Propulsion Technology Demonstration Mission (SEP TDM). The Asteroid Redirect Robotic mission is one candidate SEP TDM, which is projected to require tens of thousands of thruster life. As thruster life is increased, for example through the use of improved magnetic field designs, the relative influence of facility effects increases. One such effect is the sputtering and redeposition, or back sputter, of facility materials by the high energy thruster plumes. In support of wear testing for the Hall Effect Rocket with Magnetic Shielding (HERMeS) project, the back sputter from a Hall effect thruster plume has been modeled for the NASA Glenn Research Center's Vacuum Facility 5. The predicted wear at a near-worst case condition of 600 V, 12.5 kW was found to be on the order of 1 micron/kh in a fully carbon-lined chamber. A more detailed numerical Monte Carlo code was also modified to estimate back sputter for a detailed facility and pumping configuration. This code demonstrated similar back sputter rate distributions, but is not yet accurately modeling the magnitudes. The modeling has been benchmarked to recent HERMeS wear testing, using multiple microbalance measurements. These recent measurements have yielded values on the order of 1.5 - 2 micron/kh at 600 V and 12.5 kW.

  18. NASA Agricultural Aircraft Research Program in the Langley Vortex Research Facility and the Langley Full Scale Wind Tunnel

    NASA Technical Reports Server (NTRS)

    Jordan, F. L., Jr.; Mclemore, H. C.; Bragg, M. B.

    1978-01-01

    The current status of aerial applications technology research at the Langley's Vortex Research Facility and Full-Scale Wind Tunnel is reviewed. Efforts have been directed mainly toward developing and validating the required experimental and theoretical research tools. A capability to simulate aerial dispersal of materials from agricultural airplanes with small-scale airplane models, numerical methods, and dynamically scaled test particles was demonstrated. Tests on wake modification concepts have proved the feasibility of tailoring wake properties aerodynamically to produce favorable changes in deposition and to provide drift control. An aerodynamic evaluation of the Thrush Commander 800 agricultural airplane with various dispersal systems installed is described. A number of modifications intended to provide system improvement to both airplane and dispersal system are examined, and a technique for documenting near-field spray characteristics is evaluated.

  19. The Advanced Technology Development Center (ATDC)

    NASA Technical Reports Server (NTRS)

    Clements, G. R.; Willcoxon, R. (Technical Monitor)

    2001-01-01

    NASA is building the Advanced Technology Development Center (ATDC) to provide a 'national resource' for the research, development, demonstration, testing, and qualification of Spaceport and Range Technologies. The ATDC will be located at Space Launch Complex 20 (SLC-20) at Cape Canaveral Air Force Station (CCAFS) in Florida. SLC-20 currently provides a processing and launch capability for small-scale rockets; this capability will be augmented with additional ATDC facilities to provide a comprehensive and integrated in situ environment. Examples of Spaceport Technologies that will be supported by ATDC infrastructure include densified cryogenic systems, intelligent automated umbilicals, integrated vehicle health management systems, next-generation safety systems, and advanced range systems. The ATDC can be thought of as a prototype spaceport where industry, government, and academia, in partnership, can work together to improve safety of future space initiatives. The ATDC is being deployed in five separate phases. Major ATDC facilities will include a Liquid Oxygen Area; a Liquid Hydrogen Area, a Liquid Nitrogen Area, and a multipurpose Launch Mount; 'Iron Rocket' Test Demonstrator; a Processing Facility with a Checkout and Control System; and Future Infrastructure Developments. Initial ATDC development will be completed in 2006.

  20. Effectiveness of Qigong in promoting the health of wheelchair-bound older adults in long-term care facilities.

    PubMed

    Kuan, Shu-Chien; Chen, Kuei-Min; Wang, Chi

    2012-04-01

    Institutional wheelchair-bound older adults often do not get regular exercise and are prone to health problems. The aim of this study was to test the effects of a 12-week qigong exercise program on the physiological and psychological health of wheelchair-bound older adults in long-term care facilities. Study design was quasi-experimental, pre-post test, nonequivalent control group. Participants comprised a convenience sample of 72 wheelchair-bound older adults (qigong = 34; control = 38). The qigong group exercised 35 min/day, 5 days/week for 12 weeks. Measures for physical health (blood pressure, heart rate variability, and distal skin temperature) and psychological health (Brief Symptom Rating Scale-5) were collected before and during study Weeks 4, 8, and 12. The qigong group participants' blood pressure, distal skin temperature, and psychological health were significantly improved (all p < .001). These findings suggest that qigong exercise is a suitable daily activity for elderly residents in long-term care facilities and may help in the control of blood pressure among older adults.

  1. Computing Q-D Relationships for Storage of Rocket Fuels

    NASA Technical Reports Server (NTRS)

    Jester, Keith

    2005-01-01

    The Quantity Distance Measurement Tool is a GIS BASEP computer program that aids safety engineers by calculating quantity-distance (Q-D) relationships for vessels that contain explosive chemicals used in testing rocket engines. (Q-D relationships are standard relationships between specified quantities of specified explosive materials and minimum distances by which they must be separated from persons, objects, and other explosives to obtain specified types and degrees of protection.) The program uses customized geographic-information-system (GIS) software and calculates Q-D relationships in accordance with NASA's Safety Standard For Explosives, Propellants, and Pyrotechnics. Displays generated by the program enable the identification of hazards, showing the relationships of propellant-storage-vessel safety buffers to inhabited facilities and public roads. Current Q-D information is calculated and maintained in graphical form for all vessels that contain propellants or other chemicals, the explosiveness of which is expressed in TNT equivalents [amounts of trinitrotoluene (TNT) having equivalent explosive effects]. The program is useful in the acquisition, siting, construction, and/or modification of storage vessels and other facilities in the development of an improved test-facility safety program.

  2. Jumping combined exercise programs reduce fall risk and improve balance and life quality of elderly people who live in a long-term care facility.

    PubMed

    Cakar, E; Dincer, U; Kiralp, M Z; Cakar, D B; Durmus, O; Kilac, H; Soydan, F C; Sevinc, S; Alper, C

    2010-03-01

    The objective of this study was to determine whether regular combined exercise program, which consists strength, stretching and aerobic exercises and additional jumping training, improve balance, fall risk, quality of life and depression status of older people living in a residential care. A total of 168 residents who live in a long term care facility were screened. The trial began with 78 eligible participants and they were randomly grouped as combined exercises program (COM) group that includes stretching, strength and aerobic exercises, and COM plus jumping (COMpJ) group. 66 of the participants finished the trial. The groups were convened three times a week for six weeks. Each group had a warm-up, effective training and a cooling down periods. The total exercising time was no longer than 45 minutes in each group. Berg balance test and Biodex Balance System for the assessment of the dynamic balance and fall risk, short form 36 (SF 36) for the health related quality of life and Geriatric Depression Scale (GDS) for evaluation of the depression status were used. The balance improvement and fall risk reduction were observed in both of the groups at the end of the trial; however, the improvements were statistically better in jumping combined group. Also health related quality of life improved in both groups. Regular group exercise in a long term care facility have several beneficial effects on the elderly residents in regard to balance improvement, fall risk reduction and quality of life. The addition of jumping to strength, stretching and aerobic exercises provides important contributions to balance improvement and fall risk reduction.

  3. Expanded Quality Management Using Information Power (EQUIP): protocol for a quasi-experimental study to improve maternal and newborn health in Tanzania and Uganda

    PubMed Central

    2014-01-01

    Background Maternal and newborn mortality remain unacceptably high in sub-Saharan Africa. Tanzania and Uganda are committed to reduce maternal and newborn mortality, but progress has been limited and many essential interventions are unavailable in primary and referral facilities. Quality management has the potential to overcome low implementation levels by assisting teams of health workers and others finding local solutions to problems in delivering quality care and the underutilization of health services by the community. Existing evidence of the effect of quality management on health worker performance in these contexts has important limitations, and the feasibility of expanding quality management to the community level is unknown. We aim to assess quality management at the district, facility, and community levels, supported by information from high-quality, continuous surveys, and report effects of the quality management intervention on the utilization and quality of services in Tanzania and Uganda. Methods In Uganda and Tanzania, the Expanded Quality Management Using Information Power (EQUIP) intervention is implemented in one intervention district and evaluated using a plausibility design with one non-randomly selected comparison district. The quality management approach is based on the collaborative model for improvement, in which groups of quality improvement teams test new implementation strategies (change ideas) and periodically meet to share results and identify the best strategies. The teams use locally-generated community and health facility data to monitor improvements. In addition, data from continuous health facility and household surveys are used to guide prioritization and decision making by quality improvement teams as well as for evaluation of the intervention. These data include input, process, output, coverage, implementation practice, and client satisfaction indicators in both intervention and comparison districts. Thus, intervention districts receive quality management and continuous surveys, and comparison districts-only continuous surveys. Discussion EQUIP is a district-scale, proof-of-concept study that evaluates a quality management approach for maternal and newborn health including communities, health facilities, and district health managers, supported by high-quality data from independent continuous household and health facility surveys. The study will generate robust evidence about the effectiveness of quality management and will inform future nationwide implementation approaches for health system strengthening in low-resource settings. Trial registration PACTR201311000681314 PMID:24690284

  4. Expanded Quality Management Using Information Power (EQUIP): protocol for a quasi-experimental study to improve maternal and newborn health in Tanzania and Uganda.

    PubMed

    Hanson, Claudia; Waiswa, Peter; Marchant, Tanya; Marx, Michael; Manzi, Fatuma; Mbaruku, Godfrey; Rowe, Alex; Tomson, Göran; Schellenberg, Joanna; Peterson, Stefan

    2014-04-02

    Maternal and newborn mortality remain unacceptably high in sub-Saharan Africa. Tanzania and Uganda are committed to reduce maternal and newborn mortality, but progress has been limited and many essential interventions are unavailable in primary and referral facilities. Quality management has the potential to overcome low implementation levels by assisting teams of health workers and others finding local solutions to problems in delivering quality care and the underutilization of health services by the community. Existing evidence of the effect of quality management on health worker performance in these contexts has important limitations, and the feasibility of expanding quality management to the community level is unknown. We aim to assess quality management at the district, facility, and community levels, supported by information from high-quality, continuous surveys, and report effects of the quality management intervention on the utilization and quality of services in Tanzania and Uganda. In Uganda and Tanzania, the Expanded Quality Management Using Information Power (EQUIP) intervention is implemented in one intervention district and evaluated using a plausibility design with one non-randomly selected comparison district. The quality management approach is based on the collaborative model for improvement, in which groups of quality improvement teams test new implementation strategies (change ideas) and periodically meet to share results and identify the best strategies. The teams use locally-generated community and health facility data to monitor improvements. In addition, data from continuous health facility and household surveys are used to guide prioritization and decision making by quality improvement teams as well as for evaluation of the intervention. These data include input, process, output, coverage, implementation practice, and client satisfaction indicators in both intervention and comparison districts. Thus, intervention districts receive quality management and continuous surveys, and comparison districts-only continuous surveys. EQUIP is a district-scale, proof-of-concept study that evaluates a quality management approach for maternal and newborn health including communities, health facilities, and district health managers, supported by high-quality data from independent continuous household and health facility surveys. The study will generate robust evidence about the effectiveness of quality management and will inform future nationwide implementation approaches for health system strengthening in low-resource settings. PACTR201311000681314.

  5. Harmonization activities of Noklus - a quality improvement organization for point-of-care laboratory examinations.

    PubMed

    Stavelin, Anne; Sandberg, Sverre

    2018-05-16

    Noklus is a non-profit quality improvement organization that focuses to improve all elements in the total testing process. The aim is to ensure that all medical laboratory examinations are ordered, performed and interpreted correctly and in accordance with the patients' needs for investigation, treatment and follow-up. For 25 years, Noklus has focused on point-of-care (POC) testing in primary healthcare laboratories and has more than 3100 voluntary participants. The Noklus quality system uses different tools to obtain harmonization and improvement: (1) external quality assessment for the pre-examination, examination and postexamination phase to monitor the harmonization process and to identify areas that need improvement and harmonization, (2) manufacturer-independent evaluations of the analytical quality and user-friendliness of POC instruments and (3) close interactions and follow-up of the participants through site visits, courses, training and guidance. Noklus also recommends which tests that should be performed in the different facilities like general practitioner offices, nursing homes, home care, etc. About 400 courses with more than 6000 delegates are organized annually. In 2017, more than 21,000 e-learning programs were completed.

  6. RESULTS FROM A DEMONSTRATION OF RF-BASED UF6 CYLINDER ACCOUNTING AND TRACKING SYSTEM INSTALLED AT A USEC FACILITY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pickett, Chris A; Kovacic, Donald N; Morgan, Jim

    Approved industry-standard cylinders are used globally for storing and transporting uranium hexafluoride (UF{sub 6}) at uranium enrichment plants and processing facilities. To verify that no diversion or undeclared production of nuclear material involving UF{sub 6} cylinders at the facility has occurred, the International Atomic Energy Agency (IAEA) conducts periodic, labor-intensive physical inspections to validate facility records, cylinder identities, and cylinder weights. A reliable cylinder monitoring system that would improve overall inspector effectiveness would be a significant improvement to the current international safeguards inspection regime. Such a system could include real-time unattended monitoring of cylinder movements, situation-specific rules-based event detection algorithms,more » and the capability to integrate with other types of safeguards technologies. This type of system could provide timely detection of abnormal operational activities that may be used to ensure more appropriate and efficient responses by the IAEA. A system of this type can reduce the reliance on paper records and have the additional benefit of facilitating domestic safeguards at the facilities at which it is installed. A radio-frequency (RF)-based system designed to track uranium hexafluoride (UF{sub 6}) cylinders during processing operations was designed, assembled, and tested at the United States Enrichment Corporation (USEC) facility in Portsmouth, Ohio, to determine the operational feasibility and durability of RF technology. The overall objective of the effort was to validate the robustness of RF technology for potential use as a future international safeguards tool for tracking UF6 cylinders at uranium-processing facilities. The results to date indicate that RF tags represent a feasible technique for tracking UF{sub 6} cylinders in operating facilities. Additional work will be needed to improve the operational robustness of the tags for repeated autoclave processing and to add tamper-indicating and data authentication features to some of the pertinent system components. Future efforts will focus on these needs along with implementing protocols relevant to IAEA safeguards. The work detailed in this report demonstrates the feasibility of constructing RF devices that can survive the operational rigors associated with the transportation, storage, and processing of UF6 cylinders. The system software specially designed for this project is called Cylinder Accounting and Tracking System (CATS). This report details the elements of the CATS rules-based architecture and its use in safeguards-monitoring and asset-tracking applications. Information is also provided on improvements needed to make the technology ready, as well as options for improving the safeguards aspects of the technology. The report also includes feedback from personnel involved in the testing, as well as individuals who could utilize an RF-based system in supporting the performance of their work. The system software was set up to support a Mailbox declaration, where a declaration can be made either before or after cylinder movements take place. When the declaration is made before cylinders move, the operators must enter this information into CATS. If the IAEA then shows up unexpectedly at the facility, they can see how closely the operational condition matches the declaration. If the declaration is made after the cylinders move, this provides greater operational flexibility when schedules are interrupted or are changed, by allowing operators to declare what moves have been completed. The IAEA can then compare where cylinders are with where CATS or the system says they are located. The ability of CATS to automatically generate Mailbox declarations is seen by the authors as a desirable feature. The Mailbox approach is accepted by the IAEA but has not been widely implemented (and never in enrichment facilities). During the course of this project, we have incorporated alternative methods for implementation.« less

  7. Multiple ART Programs Create a Dilemma for Providers to Monitor ARV Adherence in Uganda.

    PubMed

    Obua, Celestino; Gusdal, Annelie; Waako, Paul; Chalker, John C; Tomson, Goran; Wahlström, Rolf; Team, The Inrud-Iaa

    2011-01-01

    Increased availability and accessibility of antiretroviral therapy (ART) has improved the length and quality of life amongst people living with HIV/AIDS. This has changed the landscape for care from episodic to long-term care that requires more monitoring of adherence. This has led to increased demand on human resources, a major problem for most ART programs. This paper presents experiences and perspectives of providers in ART facilities, exploring the organizational factors affecting their capacity to monitor adherence to ARVs. From an earlier survey to test adherence indicators and rank facilities as good, medium or poor adherence performances, six facilities were randomly selected, two from each rank. Observations on facility set-up, provider-patient interactions and key informant interviews were carried out. The strengths, weaknesses, opportunities and threats identified by health workers as facilitators or barriers to their capacity to monitor adherence to ARVs were explored during group discussions. Findings show that the performance levels of the facilities were characterized by four different organizational ART programs operating in Uganda, with apparent lack of integration and coordination at the facilities. Of the six facilities studied, the two high adherence performing facilities were Non-Governmental Organization (NGO) programs, while facilities with dual organizational programs (Governmental/NGO) performed poorly. Working conditions, record keeping and the duality of programs underscored the providers' capacity to monitor adherence. Overall 70% of the observed provider-patient interactions were conducted in environments that ensured privacy of the patient. The mean performance for record keeping was 79% and 50% in the high and low performing facilities respectively. Providers often found it difficult to monitor adherence due to the conflicting demands from the different organizational ART programs. Organizational duality at facilities is a major factor in poor adherence monitoring. The different ART programs in Uganda need to be coordinated and integrated into a single well resourced program to improve ART services and adherence monitoring. The focus on long-term care of patients on ART requires that the limitations to providers' capacity for monitoring adherence become central during the planning and implementation of ART programs.

  8. NASA-STD-6001B Test 7: Impact of Test Methodology and Detection Advancements on the Obsolescence of Historical Offgas Data

    NASA Technical Reports Server (NTRS)

    Buchanan, Vanessa D.; Woods, Brenton; Harper, Susana A.; Beeson, Harold D.; Perez, Horacio; Ryder, Valerie; Tapia, Alma S.; Pedley, Michael D.

    2017-01-01

    NASA-STD-6001B states "all nonmetals tested in accordance with NASA-STD-6001 should be retested every 10 years or as required by the responsible program/project." The retesting of materials helps ensure the most accurate data are used in material selection. Manufacturer formulas and processes can change over time, sometimes without an update to product number and material information. Material performance in certain NASA-STD-6001 tests can be particularly vulnerable to these changes, such as material offgas (Test 7). In addition, Test 7 analysis techniques at NASA White Sands Test Facility were dramatically enhanced in the early 1990s, resulting in improved detection capabilities. Low level formaldehyde identification was improved again in 2004. Understanding the limitations in offgas analysis data prior to 1990 puts into question the validity and current applicability of that data. Case studies on Super Koropon (Registered trademark) and Aeroglaze (Registered trademark) topcoat highlight the importance of material retesting.

  9. Strengthening health facilities for maternal and newborn care: experiences from rural eastern Uganda

    PubMed Central

    Namazzi, Gertrude; Waiswa, Peter; Nakakeeto, Margaret; Nakibuuka, Victoria K.; Namutamba, Sarah; Najjemba, Maria; Namusaabi, Ruth; Tagoola, Abner; Nakate, Grace; Ajeani, Judith; Peterson, Stefan; Byaruhanga, Romano N.

    2015-01-01

    Background In Uganda maternal and neonatal mortality remains high due to a number of factors, including poor quality of care at health facilities. Objective This paper describes the experience of building capacity for maternal and newborn care at a district hospital and lower-level health facilities in eastern Uganda within the existing system parameters and a robust community outreach programme. Design This health system strengthening study, part of the Uganda Newborn Study (UNEST), aimed to increase frontline health worker capacity through district-led training, support supervision, and mentoring at one district hospital and 19 lower-level facilities. A once-off supply of essential medicines and equipment was provided to address immediate critical gaps. Health workers were empowered to requisition subsequent supplies through use of district resources. Minimal infrastructure adjustments were provided. Quantitative data collection was done within routine process monitoring and qualitative data were collected during support supervision visits. We use the World Health Organization Health System Building Blocks to describe the process of district-led health facility strengthening. Results Seventy two per cent of eligible health workers were trained. The mean post-training knowledge score was 68% compared to 32% in the pre-training test, and 80% 1 year later. Health worker skills and competencies in care of high-risk babies improved following support supervision and mentoring. Health facility deliveries increased from 3,151 to 4,115 (a 30% increase) in 2 years. Of 547 preterm babies admitted to the newly introduced kangaroo mother care (KMC) unit, 85% were discharged alive to continue KMC at home. There was a non-significant declining trend for in-hospital neonatal deaths across the 2-year study period. While equipment levels remained high after initial improvement efforts, maintaining supply of even the most basic medications was a challenge, with less than 40% of health facilities reporting no stock-outs. Conclusion Health system strengthening for care at birth and the newborn period is possible even in low-resource settings and can be associated with improved utilisation and outcomes. Through a participatory process with wide engagement, training, and improvements to support supervision and logistics, health workers were able to change behaviours and practices for maternal and newborn care. Local solutions are needed to ensure sustainability of medical commodities. PMID:25843496

  10. First regulatory inspections measuring adherence to Good Pharmacy Practices in the public sector in Uganda: a cross-sectional comparison of performance between supervised and unsupervised facilities.

    PubMed

    Trap, Birna; Kikule, Kate; Vialle-Valentin, Catherine; Musoke, Richard; Lajul, Grace Otto; Hoppenworth, Kim; Konradsen, Dorthe

    2016-01-01

    Since its inception, the Uganda National Drug Authority (NDA) has regularly inspected private sector pharmacies to monitor adherence to Good Pharmacy Practices (GPP). This study reports findings from the first public facility inspections following an intervention (SPARS: Supervision, Performance Assessment, and Recognition Strategy) to build GPP and medicines management capacity in the public sector. The study includes 455 public facilities: 417 facilities were inspected after at least four SPARS visits by trained managerial district staff (SPARS group), 38 before any exposure to SPARS. NDA inspectors measured 10 critical, 20 major, and 37 minor GPP indicators in every facility and only accredited facilities that passed all 10 critical and failed no more than 7 major indicators. Lack of compliance for a given indicator was defined as less than 75 % facilities passing that indicator. We assessed factors associated with certification using logistic regression analysis and compared number of failed indicators between the SPARS and comparative groups using two sample t-tests with equal or unequal variance. 57.4 % of inspected facilities obtained GPP certification: 57.1 % in the SPARS and 60.5 % in the comparative group (Adj. OR = 0.91, 95 % CI 0.45-1.85, p = 0.802). Overall, facilities failed an average of 10 indicators. SPARS facilities performed better than comparative facilities (9 (SD 6.1) vs. 13 (SD 7.7) failed indicators respectively; p = 0.017), and SPARS supported facilities scored better on indicators covered by SPARS. For all indicators but one minor, performance in the SPARS group was equal to or significantly better than in unsupervised facilities. Within the SPARS (intervention) group, certified facilities had < 75 % compliance on 7 indicators (all minor), and uncertified facilities on 19 (4 critical, 2 major, and 13 minor) indicators. Half of the Ugandan population obtains medicines from the public sector. Yet, we found only 3/5 of inspected public health facilities meet GPP standards. SPARS facilities tended to perform better than unsupervised facilities, substantiating the value of supporting supervision interventions in GPP areas that need strengthening. None compliant indicators can be improved through practices and behavioral changes; some require infrastructure investments. We conclude that regular NDA inspections of public sector pharmacies in conjunction with interventions to improve GPP adherence can revolutionize patient care in Uganda.

  11. Advanced Disease at Enrollment in HIV Care in Four Sub-Saharan African Countries: Change from 2006-2011 and Multi-Level Predictors in 2011

    PubMed Central

    Hoffman, Susie; Wu, Yingfeng; Lahuerta, Maria; Kulkarni, Sarah Gorrell; Nuwagaba-Biribonwoha, Harriet; Sadr, Wafaa El; Remien, Robert H.; Mugisha, Veronicah; Hawken, Mark; Chuva, Ema; Nash, Denis; Elul, Batya

    2015-01-01

    Objectives To examine changes between 2006 and 2011 in the proportion of HIV-positive patients newly-enrolled in HIV care with advanced disease and the median CD4+ cell count at enrollment; and identify patient-, facility-, and contextual-level factors associated with late enrollment in care in 2011. Design Cross sectional over time. Methods For time trends analyses, routinely-collected patient-level data (307,110 adults newly-enrolled in 138 HIV clinical care facilities) in Kenya, Mozambique, Rwanda and Tanzania; and for analyses of correlates, patient-level data (46,201 in 195 facilities), and facility- and population-level survey data were used. Late enrollment was defined as CD4+ count ≤350 cells/μl and/or WHO clinical stage 3/4. Results Late enrollment declined from 69.9% to 57.2%, (p<0.0001); median CD4+ count increased from 242 to 292 cells/μL (ptrend<0.0001). In 2011, risk of late enrollment was significantly higher for men and non-pregnant women vs. pregnant women; patients aged >25 vs. 15-25 years; non-married vs. married; and those entering from sites other than prevention of mother to child transmission (PMTCT). More extensive HIV testing coverage in the region of a facility was significantly associated with lower risk of late enrollment. Conclusions Despite improvement, in 2011, 57% of patients entered HIV care already ART-eligible. The lower risk of late enrollment among those referred from PMTCT and in regions where HIV testing coverage was higher suggests that innovative approaches to rapidly increase testing uptake among people living with HIV prior to the development of symptoms have the potential to reduce late enrollment in care. PMID:25136842

  12. An inventory of aeronautical ground research facilities. Volume 3: Structural

    NASA Technical Reports Server (NTRS)

    Pirrello, C. J.; Hardin, R. D.; Heckart, M. V.; Brown, K. R.

    1971-01-01

    An inventory of test facilities for conducting acceleration, environmental, impact, structural shock, load, heat, vibration, and noise tests is presented. The facility is identified with a description of the equipment, the testing capabilities, and cost of operation. Performance data for the facility are presented in charts and tables.

  13. 46 CFR 162.050-15 - Designation of facilities.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    .... This is the mean and standard deviation, respectively, of the differences between the known sample... sample analysis, and the materials necessary to perform the tests; (2) Each facility test rig must be of... facilities. (a) Each request for designation as a facility authorized to perform approval tests must be...

  14. Autoclave Meltout of Cast Explosives

    DTIC Science & Technology

    1996-08-22

    various tanks , kettles , and pelletizing equipment a usable product was recovered. This process creates large amounts of pink water requiring...vacuum treatment melt kettles , flaker belts, and improved material handling equipment in an integrated system. During the 1976/1977 period, AED...McAlester Army Ammo Plant , Oklahoma, to discuss proposed workload and inspect available facilities and equipment . Pilot model production and testing

  15. IMPROVING HUMAN HEALTH RISK ASSESSMENT FOR TETRACHLOROETHENE BY USING BIOMARKERS AND NEUROBEHAVIORAL TESTING IN DIVERSE RESIDENTIAL POPULATIONS

    EPA Science Inventory

    The U.S. EPA considers tetrachloroethene (perc) a problematic pollutant in urban areas. The New York State Department of Health (NYSDOH) has documented high levels of perc in the indoor air of apartments located in the same buildings as dry cleaning facilities in New York Stat...

  16. 40 CFR 792.43 - Test system care facilities.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... (a) A testing facility shall have a sufficient number of animal rooms or other test system areas, as... accomplished within a room or area by housing them separately in different chambers or aquaria. Separation of... different tests. (b) A testing facility shall have a number of animal rooms or other test system areas...

  17. 40 CFR 792.43 - Test system care facilities.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... (a) A testing facility shall have a sufficient number of animal rooms or other test system areas, as... accomplished within a room or area by housing them separately in different chambers or aquaria. Separation of... different tests. (b) A testing facility shall have a number of animal rooms or other test system areas...

  18. 40 CFR 792.43 - Test system care facilities.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... (a) A testing facility shall have a sufficient number of animal rooms or other test system areas, as... accomplished within a room or area by housing them separately in different chambers or aquaria. Separation of... different tests. (b) A testing facility shall have a number of animal rooms or other test system areas...

  19. Modifications to Marshall's Annular Seal Test (MAST) Rig and Facility for Improved Rotordynamic Coefficient Testing of Annular Seals and Fluid Film Bearings

    NASA Technical Reports Server (NTRS)

    Darden, J. M.; Earhart, E. M.

    2011-01-01

    The limits of rotordynamic stability continue to be pushed by the high power densities and rotational speeds of modern rocket engine turbomachinery. Destabilizing forces increase dramatically with rotor speed. Rotordynamic stability is lost when these destabilizing forces overwhelm the stabilizing forces. The vibration from the unstable rotor grows until it is limited by some nonlinearity. For example, a rolling element bearing with a stiffness characteristic that increases with deflection may limit the vibration amplitude. The loads and deflections resulting from this limit cycle vibration (LCV) can lead to bearing and seal damage which promotes ever increasing levels of subsynchronous vibration. Engineers combat LCV by introducing rotordynamic elements that generate increased stabilizing forces and reduced destabilizing forces. For example, replacing a labyrinth seal with a damping seal results in substantial increases in the damping and stiffness rotordynamic coefficients. Adding a swirl brake to the damping seal greatly reduces the destabilizing cross-coupled forces generated by the damping seal for even further increases in the stabilizing capacity. Marshall?s Annular Seal Test (MAST) rig is designed to experimentally measure the stabilizing capacity of new annular seal designs. The rig has been moved to a new facility and outfitted with a new slave bearing to allow increased test durations and to enable the testing of fluid film bearings. The purpose of this paper is to describe the new facility and the new bearing arrangement. Several novel seal and bearing designs will also be discussed.

  20. Calibration of the NASA Glenn 8- by 6-Foot Supersonic Wind Tunnel (1996 and 1997 Tests)

    NASA Technical Reports Server (NTRS)

    Arrington, E. Allen

    2012-01-01

    There were several physical and operational changes made to the NASA Glenn Research Center 8- by 6-Foot Supersonic Wind Tunnel during the period of 1992 through 1996. Following each of these changes, a facility calibration was conducted to provide the required information to support the research test programs. Due to several factors (facility research test schedule, facility downtime and continued facility upgrades), a full test section calibration was not conducted until 1996. This calibration test incorporated all test section configurations and covered the existing operating range of the facility. However, near the end of that test entry, two of the vortex generators mounted on the compressor exit tailcone failed causing minor damage to the honeycomb flow straightener. The vortex generators were removed from the facility and calibration testing was terminated. A follow-up test entry was conducted in 1997 in order to fully calibrate the facility without the effects of the vortex generators and to provide a complete calibration of the newly expanded low speed operating range. During the 1997 tunnel entry, all planned test points required for a complete test section calibration were obtained. This data set included detailed in-plane and axial flow field distributions for use in quantifying the test section flow quality.

  1. Feasibility study of a gamma camera for monitoring nuclear materials in the PRIDE facility

    NASA Astrophysics Data System (ADS)

    Jo, Woo Jin; Kim, Hyun-Il; An, Su Jung; Lee, Chae Young; Song, Han-Kyeol; Chung, Yong Hyun; Shin, Hee-Sung; Ahn, Seong-Kyu; Park, Se-Hwan

    2014-05-01

    The Korea Atomic Energy Research Institute (KAERI) has been developing pyroprocessing technology, in which actinides are recovered together with plutonium. There is no pure plutonium stream in the process, so it has an advantage of proliferation resistance. Tracking and monitoring of nuclear materials through the pyroprocess can significantly improve the transparency of the operation and safeguards. An inactive engineering-scale integrated pyroprocess facility, which is the PyRoprocess Integrated inactive DEmonstration (PRIDE) facility, was constructed to demonstrate engineering-scale processes and the integration of each unit process. the PRIDE facility may be a good test bed to investigate the feasibility of a nuclear material monitoring system. In this study, we designed a gamma camera system for nuclear material monitoring in the PRIDE facility by using a Monte Carlo simulation, and we validated the feasibility of this system. Two scenarios, according to locations of the gamma camera, were simulated using GATE (GEANT4 Application for Tomographic Emission) version 6. A prototype gamma camera with a diverging-slat collimator was developed, and the simulated and experimented results agreed well with each other. These results indicate that a gamma camera to monitor the nuclear material in the PRIDE facility can be developed.

  2. Travel time to maternity care and its effect on utilization in rural Ghana: a multilevel analysis.

    PubMed

    Masters, Samuel H; Burstein, Roy; Amofah, George; Abaogye, Patrick; Kumar, Santosh; Hanlon, Michael

    2013-09-01

    Rates of neonatal and maternal mortality are high in Ghana. In-facility delivery and other maternal services could reduce this burden, yet utilization rates of key maternal services are relatively low, especially in rural areas. We tested a theoretical implication that travel time negatively affects the use of in-facility delivery and other maternal services. Empirically, we used geospatial techniques to estimate travel times between populations and health facilities. To account for uncertainty in Ghana Demographic and Health Survey cluster locations, we adopted a novel approach of treating the location selection as an imputation problem. We estimated a multilevel random-intercept logistic regression model. For rural households, we found that travel time had a significant effect on the likelihood of in-facility delivery and antenatal care visits, holding constant education, wealth, maternal age, facility capacity, female autonomy, and the season of birth. In contrast, a facility's capacity to provide sophisticated maternity care had no detectable effect on utilization. As the Ghanaian health network expands, our results suggest that increasing the availability of basic obstetric services and improving transport infrastructure may be important interventions. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Engine component instrumentation development facility at NASA Lewis Research Center

    NASA Technical Reports Server (NTRS)

    Bruckner, Robert J.; Buggele, Alvin E.; Lepicovsky, Jan

    1992-01-01

    The Engine Components Instrumentation Development Facility at NASA Lewis is a unique aeronautics facility dedicated to the development of innovative instrumentation for turbine engine component testing. Containing two separate wind tunnels, the facility is capable of simulating many flow conditions found in most turbine engine components. This facility's broad range of capabilities as well as its versatility provide an excellent location for the development of novel testing techniques. These capabilities thus allow a more efficient use of larger and more complex engine component test facilities.

  4. Measuring Work Environment and Performance in Nursing Homes

    PubMed Central

    Temkin-Greener, Helena; Zheng, Nan (Tracy); Katz, Paul; Zhao, Hongwei; Mukamel, Dana B.

    2008-01-01

    Background Qualitative studies of the nursing home work environment have long suggested that such attributes as leadership and communication may be related to nursing home performance, including residents' outcomes. However, empirical studies examining these relationships have been scant. Objectives This study is designed to: develop an instrument for measuring nursing home work environment and perceived work effectiveness; test the reliability and validity of the instrument; and identify individual and facility-level factors associated with better facility performance. Research Design and Methods The analysis was based on survey responses provided by managers (N=308) and direct care workers (N=7,418) employed in 162 facilities throughout New York State. Exploratory factor analysis, Chronbach's alphas, analysis of variance, and regression models were used to assess instrument reliability and validity. Multivariate regression models, with fixed facility effects, were used to examine factors associated with work effectiveness. Results The reliability and the validity of the survey instrument for measuring work environment and perceived work effectiveness has been demonstrated. Several individual (e.g. occupation, race) and facility characteristics (e.g. management style, workplace conditions, staffing) that are significant predictors of perceived work effectiveness were identified. Conclusions The organizational performance model used in this study recognizes the multidimensionality of the work environment in nursing homes. Our findings suggest that efforts at improving work effectiveness must also be multifaceted. Empirical findings from such a line of research may provide insights for improving the quality of the work environment and ultimately the quality of residents' care. PMID:19330892

  5. Design philosophy of the Jet Propulsion Laboratory infrared detector test facility

    NASA Technical Reports Server (NTRS)

    Burns, R.; Blessinger, M. A.

    1983-01-01

    To support the development of advanced infrared remote sensing instrumentation using line and area arrays, a test facility has been developed to characterize the detectors. The necessary performance characteristics of the facility were defined by considering current and projected requirements for detector testing. The completed facility provides the desired level of detector testing capability as well as providing ease of human interaction.

  6. Assessing reported cases of sexual and gender-based violence, causes and preventive strategies, in European asylum reception facilities.

    PubMed

    Oliveira, Charlotte; Keygnaert, Ines; Oliveira Martins, Maria do Rosário; Dias, Sónia

    2018-05-09

    Sexual and gender-based violence (SGBV) is a widespread public health problem and a violation of human rights rooted in gender and power inequities. Refugees, asylum-seekers and migrants living in European asylum reception facilities (EARF) are especially vulnerable to SGBV. To contribute to closing the gap on systematic and accurate evidence on SGBV, we aim to explore reported cases of SGBV, causes and preventable measures described by residents and professionals from EARF. We developed a cross-sectional study using the Senperforto project database. Semi-structured interviews were conducted with residents (refugees, asylum-seekers and unaccompanied minors) and professionals (service and health care providers) at EARF, in 7 European countries. We used IBM® SPSS software to analyze our data. Further, statistical tests - Chi-square Test and Fisher's exact test (5% significance level) were conducted. In total 562 respondents: 375 residents (R) and 187 professionals (P) participated in the study. The majority of respondents were male (56.9%), aged 19 to 39 years (67.3%). Respondents described 698 cases of SGBV (R 328, P 370), comprising 1110 acts of multi-types of violence. Respondents from Malta (160) and Belgium (143) reported the highest number of SGBV cases. The main reported causes were frustration and stress (R 23.6%, P 37.6%, p 0.008) and differences related with cultural background (R 19.3%, P 20.3%, p 0.884). Respondents assumed that these acts of violence could be prevented by SGBV prevention interventions (R 31.5%, P 24.7%, p 0.293); improving living conditions (R 21.7%, P 15.3%, p 0.232); and promoting communication (R 16.1%, P 28.2%, p 0.042). The majority of R were not aware of existing preventable measures in the asylum facility or host country. While the majority of P were aware of existing preventable measures in the asylum facility or country. Proposed SGBV prevention strategies in EARF included SGBV sensitization and awareness, improving living conditions and improving communication between R and P. In the EARF context, SGBV is characterized by multi-types of violence acts, yet R and P believe that prevention is possible. Our results call for urgent integrative prevention strategies that are in line with country-level and international regulations.

  7. SLAC All Access: FACET

    ScienceCinema

    Hogan, Mark

    2018-02-13

    SLAC's Facility for Advanced Accelerator Experimental Tests, or FACET, is a test-bed where researchers are developing the technologies required for particle accelerators of the future. Scientists from all over the world come to explore ways of improving the power and efficiency of the particle accelerators used in basic research, medicine, industry and other areas important to society. In this video, Mark Hogan, head of SLAC's Advanced Accelerator Research Department, offers a glimpse into FACET, which uses part of SLAC's historic two-mile-long linear accelerator.

  8. Analysis of the flow in a 1-MJ electric-arc shock tunnel

    NASA Technical Reports Server (NTRS)

    Reller, J. O., Jr.; Reddy, N. M.

    1972-01-01

    In the electric-arc-heated shock tunnel, the facility performance over a range of shock Mach numbers from 7 to 19 was evaluated. The efficiency of the arc-heated driver is deduced using an improved form of the shock tube equation. A theoretical and experimental analysis is made of the tailored-interface condition. The free stream properties in the test section, with nitrogen as the test gas, are evaluated using a method based on stagnation point, heat transfer measurements.

  9. Augmentor transient capability of an F100 engine equipped with a digital electronic engine control

    NASA Technical Reports Server (NTRS)

    Burcham, F. W., Jr.; Pai, G. D.

    1984-01-01

    An F100 augmented turbofan engine equipped with digital electronic engine control (DEEC) system was evaluated. The engine was equipped with a specially modified augmentor to provide improved steady state and transient augmentor capability. The combination of the DEEC and the modified augmentor was evaluated in sea level and altitude facility tests and then in four different flight phases in an F-15 aircraft. The augmentor configuration, logic, and test results are presented.

  10. Improving calorimeter resolution using temperature compensation calculations

    NASA Astrophysics Data System (ADS)

    Smiga, Joseph; Purschke, Martin

    2017-01-01

    The sPHENIX experiment is an upgrade of the existing PHENIX apparatus at the Relativistic Heavy-Ion Collider (RHIC). The new detector improves upon measurements of various physical processes, such as jets of particles created during heavy-ion collisions. Prototypes of various calorimeter components were tested at the Fermilab Test Beam Facility (FTBF). This analysis tries to compensate the effects of temperature drifts in the silicon photomultipliers (SiPMs). Temperature data were used to calculate an appropriate compensation factor. This analysis will improve the achievable resolution and will also determine how accurately the temperature must be controlled in the final experiment. This will improve the performance of the calorimeters in the sPHENIX experiment. This project was supported in part by the U.S. Department of Energy, Office of Science, Office of Workforce Development for Teachers and Scientists (WDTS) under the Science Undergraduate Laboratory Internships Program (SULI).

  11. Flow behavior in the Wright Brothers Facility

    NASA Technical Reports Server (NTRS)

    Genn, S.

    1984-01-01

    It has become increasingly apparent that a reexamination of the flow characteristics in the low speed Wright Brothers Facility (WBF) is of some importance in view of recent improvements in the precision of the data acquisition system. In particular, the existence of local regions of separation, if any, in back portions of the circuit, and possible related unsteadiness, are of interest. Observations from that initial experiment did indicate some unsteady air flow problems in the cross leg, and thereafter the test region (Section A) was calibrated quantitatively. The intent was to learn something about the effect of upstream intermittent behavior flow on the test section flow, as well as to provide an extensive calibration as a standard for the effects induced by future alteration of the tunnel. Distributions of total pressure coefficients were measured first at one cross-section plane of the test section, namely the model station. Data were obtained for several tunnel speeds. The reduced data yielded an unexpected distribution involving larger pressures along the inside wall.

  12. Investigation of Aerodynamics Scale Effects for a Generic Fighter Configuration in the National Transonic Facility (Invited)

    NASA Technical Reports Server (NTRS)

    Tomek, W. G.; Wahls, R. A.; Owens, L. R.; Burner, A. B.; Graves, S. S.; Luckring, J. M.

    2003-01-01

    Two wind tunnel tests of a generic fighter configuration have been completed in the National Transonic Facility. The primary purpose of the tests was to assess Reynolds number scale effects on a thin-wing, fighter-type configuration up to full-scale flight conditions (that is, Reynolds numbers of the order of 60 million). The tests included longitudinal and lateral/directional studies at subsonic and transonic conditions across a range of Reynolds numbers from that available in conventional wind tunnels to flight conditions. Results are presented for three Mach numbers (0.6, 0.8, and 0.9) and three configurations: 1) Fuselage / Wing, 2) Fuselage / Wing / Centerline Vertical Tail / Horizontal Tail, and 3) Fuselage / Wing / Trailing-Edge Extension / Twin Vertical Tails. Reynolds number effects on the lateral-directional aerodynamic characteristics are presented herein, along with longitudinal data demonstrating the effects of fixing the boundary layer transition location for low Reynolds number conditions. In addition, an improved model videogrammetry system and results are discussed.

  13. An Integrated Tiered Service Delivery Model (ITSDM) Based on Local CD4 Testing Demands Can Improve Turn-Around Times and Save Costs whilst Ensuring Accessible and Scalable CD4 Services across a National Programme

    PubMed Central

    Glencross, Deborah K.; Coetzee, Lindi M.; Cassim, Naseem

    2014-01-01

    Background The South African National Health Laboratory Service (NHLS) responded to HIV treatment initiatives with two-tiered CD4 laboratory services in 2004. Increasing programmatic burden, as more patients access anti-retroviral therapy (ART), has demanded extending CD4 services to meet increasing clinical needs. The aim of this study was to review existing services and develop a service-model that integrated laboratory-based and point-of-care testing (POCT), to extend national coverage, improve local turn-around/(TAT) and contain programmatic costs. Methods NHLS Corporate Data Warehouse CD4 data, from 60–70 laboratories and 4756 referring health facilities was reviewed for referral laboratory workload, respective referring facility volumes and related TAT, from 2009–2012. Results An integrated tiered service delivery model (ITSDM) is proposed. Tier-1/POCT delivers CD4 testing at single health-clinics providing ART in hard-to-reach areas (<5 samples/day). Laboratory-based testing is extended with Tier-2/POC-Hubs (processing ≤30–40 CD4 samples/day), consolidating POCT across 8–10 health-clinics with other HIV-related testing and Tier-3/‘community’ laboratories, serving ≤40 health-clinics, processing ≤150 samples/day. Existing Tier-4/‘regional’ laboratories serve ≤100 facilities and process <350 samples/day; Tier-5 are high-volume ‘metro’/centralized laboratories (>350–1500 tests/day, serving ≥200 health-clinics). Tier-6 provides national support for standardisation, harmonization and quality across the organization. Conclusion The ITSDM offers improved local TAT by extending CD4 services into rural/remote areas with new Tier-3 or Tier-2/POC-Hub services installed in existing community laboratories, most with developed infrastructure. The advantage of lower laboratory CD4 costs and use of existing infrastructure enables subsidization of delivery of more expensive POC services, into hard-to-reach districts without reasonable access to a local CD4 laboratory. Full ITSDM implementation across 5 service tiers (as opposed to widespread implementation of POC testing to extend service) can facilitate sustainable ‘full service coverage’ across South Africa, and save>than R125 million in HIV/AIDS programmatic costs. ITSDM hierarchical parental-support also assures laboratory/POC management, equipment maintenance, quality control and on-going training between tiers. PMID:25490718

  14. Ensuring US National Aeronautics Test Capabilities

    NASA Technical Reports Server (NTRS)

    Marshall, Timothy J.

    2010-01-01

    U.S. leadership in aeronautics depends on ready access to technologically advanced, efficient, and affordable aeronautics test capabilities. These systems include major wind tunnels and propulsion test facilities and flight test capabilities. The federal government owns the majority of the major aeronautics test capabilities in the United States, primarily through the National Aeronautics and Space Administration (NASA) and the Department of Defense (DoD). However, changes in the Aerospace landscape, primarily the decrease in demand for testing over the last 20 years required an overarching strategy for management of these national assets. Therefore, NASA established the Aeronautics Test Program (ATP) as a two-pronged strategic initiative to: (1) retain and invest in NASA aeronautics test capabilities considered strategically important to the agency and the nation, and (2) establish a strong, high level partnership with the DoD. Test facility utilization is a critical factor for ATP because it relies on user occupancy fees to recover a substantial part of the operations costs for its facilities. Decreasing utilization is an indicator of excess capacity and in some cases low-risk redundancy (i.e., several facilities with basically the same capability and overall low utilization). However, low utilization does not necessarily translate to lack of strategic importance. Some facilities with relatively low utilization are nonetheless vitally important because of the unique nature of the capability and the foreseeable aeronautics testing needs. Unfortunately, since its inception, the customer base for ATP has continued to shrink. Utilization of ATP wind tunnels has declined by more than 50% from the FY 2006 levels. This significant decrease in customer usage is attributable to several factors, including the overall decline in new programs and projects in the aerospace sector; the impact of computational fluid dynamics (CFD) on the design, development, and research process; and the reductions in wind tunnel testing requirements within the largest consumer of ATP wind tunnel test time, the Aeronautics Research Mission Directorate (ARMD). Retirement of the Space Shuttle Program and recent perturbations of NASA's Constellation Program will exacerbate this downward trend. Therefore it is crucial that ATP periodically revisit and determine which of its test capabilities are strategically important, which qualify as low-risk redundancies that could be put in an inactive status or closed, and address the challenges associated with both sustainment and improvements to the test capabilities that must remain active. This presentation will provide an overview of the ATP vision, mission, and goals as well as the challenges and opportunities the program is facing both today and in the future. We will discuss the strategy ATP is taking over the next five years to address the National aeronautics test capability challenges and what the program will do to capitalize on its opportunities to ensure a ready, robust and relevant portfolio of National aeronautics test capabilities.

  15. Enhanced passive screening and diagnosis for gambiense human African trypanosomiasis in north-western Uganda – Moving towards elimination

    PubMed Central

    Bessell, Paul Richard; Ndung’u, Joseph Mathu

    2017-01-01

    Introduction The incidence of gambiense human African trypanosomiasis (gHAT) in Uganda has been declining, from 198 cases in 2008, to only 20 in 2012. Interruption of transmission of the disease by early diagnosis and treatment is core to the control and eventual elimination of gHAT. Until recently, the format of available screening tests had restricted screening and diagnosis to central health facilities (passive screening). We describe a novel strategy that is contributing to elimination of gHAT in Uganda through expansion of passive screening to the entire population at risk. Methodology / Principal findings In this strategy, patients who are clinically suspected of having gHAT at primary health facilities are screened using a rapid diagnostic test (RDT), followed by parasitological confirmation at strategically located microscopy centres. For patients who are positive with the RDT and negative by microscopy, blood samples undergo further testing using loop-mediated isothermal amplification (LAMP), a molecular test that detects parasite DNA. LAMP positive patients are considered strong suspects, and are re-evaluated by microscopy. Location and upgrading of facilities to perform microscopy and LAMP was informed by results of georeferencing and characterization of all public healthcare facilities in the 7 gHAT endemic districts in Uganda. Three facilities were upgraded to perform RDTs, microscopy and LAMP, 9 to perform RDTs and microscopy, and 200 to screen patients with RDTs. This reduced the distance that a sick person must travel to be screened for gHAT to a median distance of 2.5km compared to 23km previously. In this strategy, 9 gHAT cases were diagnosed in 2014, and 4 in 2015. Conclusions This enhanced passive screening strategy for gHAT has enabled full coverage of the population at risk, and is being replicated in other gHAT endemic countries. The improvement in case detection is making elimination of the disease in Uganda an imminent possibility. PMID:29023573

  16. Evaluating Past and Future USCG Use of Ohmsett Test Facility

    DTIC Science & Technology

    2016-10-01

    and Renewable Energy Test Facility, that was previously known as a fully capitalized acronym, Ohmsett. This facility is located on the U.S. Naval...Oil Spill Response Research and Renewable Energy Test Facility, that was previously known as a fully capitalized acronym, Ohmsett. This facility is...Incident Management Systems NSF National Strike Force NWS Naval Weapons Station Ohmsett National Oil Spill Response Research and Renewable Energy

  17. Linking data sources for measurement of effective coverage in maternal and newborn health: what do we learn from individual- vs ecological-linking methods?

    PubMed

    Willey, Barbara; Waiswa, Peter; Kajjo, Darious; Munos, Melinda; Akuze, Joseph; Allen, Elizabeth; Marchant, Tanya

    2018-06-01

    Improving maternal and newborn health requires improvements in the quality of facility-based care. This is challenging to measure: routine data may be unreliable; respondents in population surveys may be unable to accurately report on quality indicators; and facility assessments lack population level denominators. We explored methods for linking access to skilled birth attendance (SBA) from household surveys to data on provision of care from facility surveys with the aim of estimating population level effective coverage reflecting access to quality care. We used data from Mayuge District, Uganda. Data from household surveys on access to SBA were linked to health facility assessment census data on readiness to provide basic emergency obstetric and newborn care (BEmONC) in the same district. One individual- and two ecological-linking methods were applied. All methods used household survey reports on where care at birth was accessed. The individual-linking method linked this to data about facility readiness from the specific facility where each woman delivered. The first ecological-linking approach used a district-wide mean estimate of facility readiness. The second used an estimate of facility readiness adjusted by level of health facility accessed. Absolute differences between estimates derived from the different linking methods were calculated, and agreement examined using Lin's concordance correlation coefficient. A total of 1177 women resident in Mayuge reported a birth during 2012-13. Of these, 664 took place in facilities within Mayuge, and were eligible for linking to the census of the district's 38 facilities. 55% were assisted by a SBA in a facility. Using the individual-linking method, effective coverage of births that took place with an SBA in a facility ready to provide BEmONC was just 10% (95% confidence interval CI 3-17). The absolute difference between the individual- and ecological-level linking method adjusting for facility level was one percentage point (11%), and tests suggested good agreement. The ecological method using the district-wide estimate demonstrated poor agreement. The proportion of women accessing appropriately equipped facilities for care at birth is far lower than the coverage of facility delivery. To realise the life-saving potential of health services, countries need evidence to inform actions that address gaps in the provision of quality care. Linking household and facility-based information provides a simple but innovative method for estimating quality of care at the population level. These encouraging findings suggest that linking data sets can result in meaningful evidence even when the exact location of care seeking is not known.

  18. 49 CFR Appendix A to Part 665 - Tests To Be Performed at the Bus Testing Facility

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 7 2014-10-01 2014-10-01 false Tests To Be Performed at the Bus Testing Facility... Part 665—Tests To Be Performed at the Bus Testing Facility The eight tests to be performed on each vehicle are required by SAFETEA-LU and are based in part on tests described in the FTA report “First...

  19. 49 CFR Appendix A to Part 665 - Tests To Be Performed at the Bus Testing Facility

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 7 2012-10-01 2012-10-01 false Tests To Be Performed at the Bus Testing Facility... Part 665—Tests To Be Performed at the Bus Testing Facility The eight tests to be performed on each vehicle are required by SAFETEA-LU and are based in part on tests described in the FTA report “First...

  20. NASA Johnson Space Center: White Sands Test Facility

    NASA Technical Reports Server (NTRS)

    Aggarwal, Pravin; Kowalski, Robert R.

    2011-01-01

    This slide presentation reviews the testing facilities and laboratories available at the White Sands Test Facility (WSTF). The mission of WSTF is to provide the expertise and infrastructure to test and evaluate spacecraft materials, components and propulsion systems that enable the safe exploration and use of space. There are nine rocket test stands in two major test areas, six altitude test stands, three ambient test stands,

  1. STDAC: Solar thermal design assistance center annual report fiscal year 1994

    NASA Astrophysics Data System (ADS)

    The Solar Thermal Design Assistance Center (STDAC) at Sandia is a resource provided by the DOE Solar Thermal Program. The STDAC's major objective is to accelerate the use of solar thermal systems by providing direct technical assistance to users in industry, government, and foreign countries; cooperating with industry to test, evaluate, and develop renewable energy systems and components; and educating public and private professionals, administrators, and decision makers. This FY94 report highlights the activities and accomplishments of the STDAC. In 1994, the STDAC continued to provide significant direct technical assistance to domestic and international organizations in industry, government, and education, Applying solar thermal technology to solve energy problems is a vital element of direct technical assistance. The STDAC provides information on the status of new, existing, and developing solar technologies; helps users screen applications; predicts the performance of components and systems; and incorporates the experience of Sandia's solar energy personnel and facilities to provide expert guidance. The STDAC directly enhances the US solar industry's ability to successfully bring improved systems to the marketplace. By collaborating with Sandia's Photovoltaic Design Assistance Center and the National Renewable Energy Laboratory the STDAC is able to offer each customer complete service in applying solar thermal technology. At the National Solar Thermal Test Facility the STDAC tests and evaluates new and innovative solar thermal technologies. Evaluations are conducted in dose cooperation with manufacturers, and the results are used to improve the product and/or quantify its performance characteristics. Manufacturers, in turn, benefit from the improved design, economic performance, and operation of their solar thermal technology. The STDAC provides cost sharing and in-kind service to manufacturers in the development and improvement of solar technology.

  2. Alleviation of Facility/Engine Interactions in an Open-Jet Scramjet Test Facility

    NASA Technical Reports Server (NTRS)

    Albertson, Cindy W.; Emami, Saied

    2001-01-01

    Results of a series of shakedown tests to eliminate facility/engine interactions in an open-jet scramjet test facility are presented. The tests were conducted with the NASA DFX (Dual-Fuel eXperimental scramjet) engine in the NASA Langley Combustion Heated Scramjet Test Facility (CHSTF) in support of the Hyper-X program, The majority of the tests were conducted at a total enthalpy and pressure corresponding to Mach 5 flight at a dynamic pressure of 734 psf. The DFX is the largest engine ever tested in the CHSTF. Blockage, in terms of the projected engine area relative to the nozzle exit area, is 81% with the engine forebody leading edge aligned with the upper edge of the facility nozzle such that it ingests the nozzle boundary layer. The blockage increases to 95% with the engine forebody leading edge positioned 2 in. down in the core flow. Previous engines successfully tested in the CHSTF have had blockages of no more than 51%. Oil flow studies along with facility and engine pressure measurements were used to define flow behavior. These results guided modifications to existing aeroappliances and the design of new aeroappliances. These changes allowed fueled tests to be conducted without facility interaction effects in the data with the engine forebody leading edge positioned to ingest the facility nozzle boundary layer. Interaction effects were also reduced for tests with the engine forebody leading edge positioned 2 in. into the core flow, however some interaction effects were still evident in the engine data. A new shroud and diffuser have been designed with the goal of allowing fueled tests to be conducted with the engine forebody leading edge positioned in the core without facility interaction effects in the data. Evaluation tests of the new shroud and diffuser will be conducted once ongoing fueled engine tests have been completed.

  3. Development, application, and validation of a survey for infectious disease control practices at equine boarding facilities.

    PubMed

    Kirby, Alanna T; Traub-Dargatz, Josie L; Hill, Ashley E; Kogan, Lori R; Morley, Paul S; Heird, James C

    2010-11-15

    To develop a questionnaire for self-assessment of biosecurity practices at equine boarding facilities and to evaluate infectious disease control practices in these facilities in Colorado. Cross-sectional study. 64 equine boarding facilities in Colorado. Survey questions were rated according to importance for prevention and containment of equine infectious diseases. Point values (range, 0 to 20) were assigned for possible responses, with greater values given for optimal infection control methods. Questionnaires were mailed to equine boarding facilities in Colorado advertised on the World Wide Web. Survey responses were compared with assessments made by a member of the research team during visits to 30 randomly selected facilities. Agreement among results was analyzed via a kappa test and rated as poor, fair, moderate, substantial, or nearly perfect. Survey responses were received for 64 of 163 (39%) equine boarding facilities. Scores ranged from 106 to 402 points (maximum possible score, 418). Most facilities received better scores for movement and housing of equids than for other sections of the survey. Respondents at 24 of 48 (50%) facilities that routinely received new equids reported isolation of new arrivals. Agreement between self-assessment by survey respondents and evaluation by a member of the research team was determined to be fair to substantial. Most equine boarding facilities have opportunities to improve measures for prevention or containment of contagious diseases (eg, isolation of newly arrived equids and use of written health management protocols). Most self-assessments of infection control practices were accurate.

  4. Improving primary health care facility performance in Ghana: efficiency analysis and fiscal space implications.

    PubMed

    Novignon, Jacob; Nonvignon, Justice

    2017-06-12

    Health centers in Ghana play an important role in health care delivery especially in deprived communities. They usually serve as the first line of service and meet basic health care needs. Unfortunately, these facilities are faced with inadequate resources. While health policy makers seek to increase resources committed to primary healthcare, it is important to understand the nature of inefficiencies that exist in these facilities. Therefore, the objectives of this study are threefold; (i) estimate efficiency among primary health facilities (health centers), (ii) examine the potential fiscal space from improved efficiency and (iii) investigate the efficiency disparities in public and private facilities. Data was from the 2015 Access Bottlenecks, Cost and Equity (ABCE) project conducted by the Institute for Health Metrics and Evaluation. The Stochastic Frontier Analysis (SFA) was used to estimate efficiency of health facilities. Efficiency scores were then used to compute potential savings from improved efficiency. Outpatient visits was used as output while number of personnel, hospital beds, expenditure on other capital items and administration were used as inputs. Disparities in efficiency between public and private facilities was estimated using the Nopo matching decomposition procedure. Average efficiency score across all health centers included in the sample was estimated to be 0.51. Also, average efficiency was estimated to be about 0.65 and 0.50 for private and public facilities, respectively. Significant disparities in efficiency were identified across the various administrative regions. With regards to potential fiscal space, we found that, on average, facilities could save about GH₵11,450.70 (US$7633.80) if efficiency was improved. We also found that fiscal space from efficiency gains varies across rural/urban as well as private/public facilities, if best practices are followed. The matching decomposition showed an efficiency gap of 0.29 between private and public facilities. There is need for primary health facility managers to improve productivity via effective and efficient resource use. Efforts to improve efficiency should focus on training health workers and improving facility environment alongside effective monitoring and evaluation exercises.

  5. SSC Test Operations Contract Overview

    NASA Technical Reports Server (NTRS)

    Kleim, Kerry D.

    2010-01-01

    This slide presentation reviews the Test Operations Contract at the Stennis Space Center (SSC). There are views of the test stands layouts, and closer views of the test stands. There are descriptions of the test stand capabilities, some of the other test complexes, the Cryogenic propellant storage facility, the High Pressure Industrial Water (HPIW) facility, and Fluid Component Processing Facility (FCPF).

  6. Application Of Artificial Intelligence To Wind Tunnels

    NASA Technical Reports Server (NTRS)

    Lo, Ching F.; Steinle, Frank W., Jr.

    1989-01-01

    Report discusses potential use of artificial-intelligence systems to manage wind-tunnel test facilities at Ames Research Center. One of goals of program to obtain experimental data of better quality and otherwise generally increase productivity of facilities. Another goal to increase efficiency and expertise of current personnel and to retain expertise of former personnel. Third goal to increase effectiveness of management through more efficient use of accumulated data. System used to improve schedules of operation and maintenance of tunnels and other equipment, assignment of personnel, distribution of electrical power, and analysis of costs and productivity. Several commercial artificial-intelligence computer programs discussed as possible candidates for use.

  7. National Transonic Facility: A review of the operational plan

    NASA Technical Reports Server (NTRS)

    Liepmann, H. W.; Black, R. E.; Dietz, R. O.; Kirchner, M. E.; Sears, W. R.

    1980-01-01

    The proposed National Transonic Facility (NTF) operational plan is reviewed. The NTF will provide an aerodynamic test capability significantly exceeding that of other transonic regime wind tunnels now available. A limited number of academic research program that might use the NTF are suggested. It is concluded that the NTF operational plan is useful for management, technical, instrumentation, and model building techniques available in the specialized field of aerodynamic analysis and simulation. It is also suggested that NASA hold an annual conference to discuss wind tunnel research results and to report on developments that will further improve the utilization and cost effectiveness of the NTF and other wind tunnels.

  8. KSC-06pd0773

    NASA Image and Video Library

    2006-05-03

    KENNEDY SPACE CENTER, FLA. - Workers at Astrotech, a payload processing facility near Kennedy Space Center in Florida, check the second of NASA's Solar Terrestrial Relations Observatory (STEREO) spacecraft after its move into the facility. The two spacecraft will undergo preparations and final testing for launch. Liftoff will occur aboard a Boeing Delta II rocket from Launch Complex 17 on Cape Canaveral Air Force Station in the summer. STEREO consists of two spacecraft whose mission is the first to take measurements of the sun and solar wind in 3-D. This new view will improve our understanding of space weather and its impact on the Earth. Photo credit: NASA/Jim Grossmann

  9. Thermal Protection System Development, Testing and Qualification

    NASA Astrophysics Data System (ADS)

    Venkatapathy, Ethiraj; Arnold, James; Laub, B.; Hartman, G. J.

    The science community currently has interest in planetary entry probe missions to improve our understanding of the atmospheres of Saturn and Venus [1,2]. As in the case of the Galileo entry probe, such data are critical to the understanding of not only the individual planets but also to further knowledge regarding the formation of the solar system. It is believed that Saturn probes to depths corresponding to 10 bars will be sufficient [1] to provide the desired scientific data. The heating rates for the "shallow" Saturn probes and Venus are in the range of 2 - 5KW/cm2 . It is clear that new, mid-density Thermal Protection System (TPS) materials for such probes can be mission-enabling for mass efficiency [3] and also make the use of smaller vehicles possible from advancements in scientific instrumentation [4]. Past consideration of new Jovian multiprobe missions has been considered problematic without the Giant Planet Arcjet Facility that was used to qualify Carbon Phenolic for the Galileo Probe. This paper describes emerging TPS technology and the proposed use of an affordable, small 5 MW arc jet that can be used for TPS development in test gases appropriate for the aforementioned, new planetary probe applications. Emerging TPS technologies of interest include a mid-density, chopped molded carbon phenolic (CMCP) material around 0.8g/cc and a densified variant of phenolic impregnated carbon ablator (PICA) around 0.5g/cc. The small 5 MW arc jet facility, called the Development Arcjet Facility (DAF) and the methodology of testing TPS, both based on previous work, are discussed. Finally, the applications to Earth entry appropriate to speeds greater than lunar return (11km/s) are discussed as will facility-to-facility validation using air as a test gas. The use of other facilities for development, qualification and certification of TPS for Saturn and Venus is also discussed. [1] Atreya, S. K., et. al. Formation of Giant Planets and Their Atmospheres: Entry Probes for Saturn and Beyond; 5 th International Planetary Probe Workshop, June 25-29, Bordeaux, France. [2] Baines, K. H, et. al, Exploring Venus with Balloons: Science Objectives and Mission Architectures. 5 th International Planetary Probe Workshop, June 25-29 Bordeaux, France.

  10. Electronic Systems Test Laboratory (ESTL) User Test Planning Guide

    NASA Technical Reports Server (NTRS)

    Robinson, Neil

    2011-01-01

    Test process, milestones and inputs are unknowns to first-time users of the ESTL. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  11. Structures Test Laboratory (STL). User Test Planning Guide

    NASA Technical Reports Server (NTRS)

    Zipay, John J.

    2011-01-01

    Test process, milestones and inputs are unknowns to first-time users of the STL. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  12. Energy Systems Test Area (ESTA) Battery Test Operations User Test Planning Guide

    NASA Technical Reports Server (NTRS)

    Salinas, Michael

    2012-01-01

    Test process, milestones and inputs are unknowns to first-time users of the ESTA Battery Test Operations. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  13. Environmental Health Practice: Statistically Based Performance Measurement

    PubMed Central

    Enander, Richard T.; Gagnon, Ronald N.; Hanumara, R. Choudary; Park, Eugene; Armstrong, Thomas; Gute, David M.

    2007-01-01

    Objectives. State environmental and health protection agencies have traditionally relied on a facility-by-facility inspection-enforcement paradigm to achieve compliance with government regulations. We evaluated the effectiveness of a new approach that uses a self-certification random sampling design. Methods. Comprehensive environmental and occupational health data from a 3-year statewide industry self-certification initiative were collected from representative automotive refinishing facilities located in Rhode Island. Statistical comparisons between baseline and postintervention data facilitated a quantitative evaluation of statewide performance. Results. The analysis of field data collected from 82 randomly selected automotive refinishing facilities showed statistically significant improvements (P<.05, Fisher exact test) in 4 major performance categories: occupational health and safety, air pollution control, hazardous waste management, and wastewater discharge. Statistical significance was also shown when a modified Bonferroni adjustment for multiple comparisons was performed. Conclusions. Our findings suggest that the new self-certification approach to environmental and worker protection is effective and can be used as an adjunct to further enhance state and federal enforcement programs. PMID:17267709

  14. GEOTAIL Spacecraft historical data report

    NASA Technical Reports Server (NTRS)

    Boersig, George R.; Kruse, Lawrence F.

    1993-01-01

    The purpose of this GEOTAIL Historical Report is to document ground processing operations information gathered on the GEOTAIL mission during processing activities at the Cape Canaveral Air Force Station (CCAFS). It is hoped that this report may aid management analysis, improve integration processing and forecasting of processing trends, and reduce real-time schedule changes. The GEOTAIL payload is the third Delta 2 Expendable Launch Vehicle (ELV) mission to document historical data. Comparisons of planned versus as-run schedule information are displayed. Information will generally fall into the following categories: (1) payload stay times (payload processing facility/hazardous processing facility/launch complex-17A); (2) payload processing times (planned, actual); (3) schedule delays; (4) integrated test times (experiments/launch vehicle); (5) unique customer support requirements; (6) modifications performed at facilities; (7) other appropriate information (Appendices A & B); and (8) lessons learned (reference Appendix C).

  15. Tuberculosis infection control practices in a high-burden metro in South Africa: A perpetual bane for efficient primary health care service delivery.

    PubMed

    Engelbrecht, Michelle C; Kigozi, Gladys; Janse van Rensburg, Andre P; Van Rensburg, Dingie H C J

    2018-05-30

    Tuberculosis (TB) prevention, including infection control, is a key element in the strategy to end the global TB epidemic. While effective infection control requires all health system components to function well, this is an area that has not received sufficient attention inSouth Africa despite the availability of policy and guidelines. To describe the state of implementation of TB infection control measures in a high-burden metro in South Africa. The research was undertaken in a high TB- and HIV-burdened metropolitan area of South Africa. More specifically, the study sites were primary health care facilities (PHC), thatamong other services also diagnosed TB. A cross-sectional survey, focusing on the World Health Organization levels of infection control, which included structured interviews with nurses providing TB diagnosis and treatment services as well as observations, at all 41 PHC facilities in a high TB-burdened and HIV-burdened metro of South Africa. Tuberculosis infection control was poorly implemented, with few facilities scoring 80% and above on compliance with infection control measures. Facility controls: 26 facilities (63.4%) had an infection control committee and 12 (29.3%) had a written infection control plan. Administrative controls: 26 facilities (63.4%) reported separating coughing and noncoughing patients, while observations revealed that only 11 facilities (26.8%) had separate waiting areas for (presumptive) TB patients. Environmental controls: most facilities used open windows for ventilation (n = 30; 73.2%); however, on the day of the visit, only 12 facilities (30.3%) had open windows in consulting rooms. Personal protective equipment: 9 facilities (22%) did not have any disposable respirators in stock and only 9 respondents (22%) had undergone fit testing. The most frequently reported barrier to implementing good TBinfection control practices was lack of equipment (n = 22; 40%) such as masks and disposable respirators, as well as the structure or layout of the PHC facilities. The main recommendation to improve TB infection control was education for patients and health care workers (n = 18; 33.3%). All levels of the health care system should be engaged to address TB prevention and infection control in PHC facilities. Improved infection control will address the nosocomial spread of TB in health facilities and keep health care workers and patients safe from infection.

  16. Effectiveness of the WHO SCC on improving adherence to essential practices during childbirth, in resource constrained settings.

    PubMed

    Kumar, Somesh; Yadav, Vikas; Balasubramaniam, Sudharsanam; Jain, Yashpal; Joshi, Chandra Shekhar; Saran, Kailash; Sood, Bulbul

    2016-11-08

    India accounts for 27 % of world's neonatal deaths. Although more Indian women deliver in facilities currently than a decade ago, early neonatal mortality has not declined, likely because of insufficient quality of care. The WHO Safe Childbirth Checklist (SCC) was developed to support health workers to perform essential practices known to reduce preventable maternal and new-born deaths around the time of childbirth. Despite promising early research many outstanding questions remain about effectiveness of the SCC in low-resource settings. In collaboration with the Ministry of Health SCC was modified for Indian context and introduced in 101 intervention facilities in Rajasthan, India and 99 facilities served as comparison to study if it reduces mortality. This Quasi experimental Observational intervention-comparison was embedded in this larger program to test whether a program for introduction of SCC with simple implementation package was associated with increased adherence to 28 evidence-based practices. This study was conducted in 8 intervention and 8 comparison sites. Program interventions to promote appropriate use of the SCC included orienting providers to the checklist, modest modifications of the SCC to promote provider uptake and accountability, ensuring availability of essential supplies, and providing supportive supervision for helping providers in using the SCC. The SCC was used by providers in 86 % of 240 deliveries observed in the eight intervention facilities. Providers in the intervention group significantly adhered to practices included in the SCC than providers in the comparison group controlling for baseline scores and confounders. Women delivering in the intervention facilities received on an average 11.5 more of the 28 practices included compared with women in the comparison facilities. For selected practices provider performance in the intervention group increased as much as 93 % than comparison sites. Use of the SCC and provider performance of best practices increased in intervention facilities reflecting improvement in quality of facility childbirth care for women and new-born in low resource settings.

  17. Past and Present Large Solid Rocket Motor Test Capabilities

    NASA Technical Reports Server (NTRS)

    Kowalski, Robert R.; Owen, David B., II

    2011-01-01

    A study was performed to identify the current and historical trends in the capability of solid rocket motor testing in the United States. The study focused on test positions capable of testing solid rocket motors of at least 10,000 lbf thrust. Top-level information was collected for two distinct data points plus/minus a few years: 2000 (Y2K) and 2010 (Present). Data was combined from many sources, but primarily focused on data from the Chemical Propulsion Information Analysis Center s Rocket Propulsion Test Facilities Database, and heritage Chemical Propulsion Information Agency/M8 Solid Rocket Motor Static Test Facilities Manual. Data for the Rocket Propulsion Test Facilities Database and heritage M8 Solid Rocket Motor Static Test Facilities Manual is provided to the Chemical Propulsion Information Analysis Center directly from the test facilities. Information for each test cell for each time period was compiled and plotted to produce a graphical display of the changes for the nation, NASA, Department of Defense, and commercial organizations during the past ten years. Major groups of plots include test facility by geographic location, test cells by status/utilization, and test cells by maximum thrust capability. The results are discussed.

  18. Space Power Facility-Capabilities for Space Environmental Testing Within a Single Facility

    NASA Technical Reports Server (NTRS)

    Sorge, Richard N.

    2013-01-01

    The purpose of this paper is to describe the current and near-term environmental test capabilities of the NASA Glenn Research Center's Space Power Facility (SPF) located at Sandusky, Ohio. The paper will present current and near-term capabilities for conducting electromagnetic interference and compatibility testing, base-shake sinusoidal vibration testing, reverberant acoustic testing, and thermal-vacuum testing. The paper will also present modes of transportation, handling, ambient environments, and operations within the facility to conduct those tests. The SPF is in the midst of completing and activating new or refurbished capabilities which, when completed, will provide the ability to conduct most or all required full-scale end-assembly space simulation tests at a single test location. It is envisioned that the capabilities will allow a customer to perform a wide range of space simulation tests in one facility at reasonable cost.

  19. Improvement of the mechanical reliability of monolithic refractory linings for coal gasification process vessels. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Potter, R.A.

    1981-09-01

    Eighteen heat-up tests were run on nine standard and experimental dual component monolithic refractory concrete linings. These tests were run with a five foot diameter by 14-ft high Pressure Vessel/Test Furnace designed to accommodate a 12-inch thick by 5-ft high refractory lining, heat the hot face to 2000/sup 0/F and expose the lining to air or steam pressures up to 150 psig. Results obtained from standard type linings in the test facility indicated that lining degradation duplicated that observed in field installations. The lining performance was significantly improved due to information gained from a systematic study of the cracking thatmore » occurred in the linings; the analysis of the lining strains, shell stresses and acoustic emission results; and the stress analyses performed on the standard and experimental lining designs with the finite element analysis computer programs, REFSAM and RESGAP.« less

  20. 32 CFR 644.486 - Disposal of buildings and improvements constructed under emergency plant facilities (EPF) or...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Disposal of buildings and improvements constructed under emergency plant facilities (EPF) or similar contracts. 644.486 Section 644.486 National... Disposal of buildings and improvements constructed under emergency plant facilities (EPF) or similar...

Top