Sample records for test mask variable

  1. Error response test system and method using test mask variable

    NASA Technical Reports Server (NTRS)

    Gender, Thomas K. (Inventor)

    2006-01-01

    An error response test system and method with increased functionality and improved performance is provided. The error response test system provides the ability to inject errors into the application under test to test the error response of the application under test in an automated and efficient manner. The error response system injects errors into the application through a test mask variable. The test mask variable is added to the application under test. During normal operation, the test mask variable is set to allow the application under test to operate normally. During testing, the error response test system can change the test mask variable to introduce an error into the application under test. The error response system can then monitor the application under test to determine whether the application has the correct response to the error.

  2. Self-masking: Listening during vocalization. Normal hearing.

    PubMed

    Borg, Erik; Bergkvist, Christina; Gustafsson, Dan

    2009-06-01

    What underlying mechanisms are involved in the ability to talk and listen simultaneously and what role does self-masking play under conditions of hearing impairment? The purpose of the present series of studies is to describe a technique for assessment of masked thresholds during vocalization, to describe normative data for males and females, and to focus on hearing impairment. The masking effect of vocalized [a:] on narrow-band noise pulses (250-8000 Hz) was studied using the maximum vocalization method. An amplitude-modulated series of sound pulses, which sounded like a steam engine, was masked until the criterion of halving the perceived pulse rate was reached. For masking of continuous reading, a just-follow-conversation criterion was applied. Intra-session test-retest reproducibility and inter-session variability were calculated. The results showed that female voices were more efficient in masking high frequency noise bursts than male voices and more efficient in masking both a male and a female test reading. The male had to vocalize 4 dBA louder than the female to produce the same masking effect on the test reading. It is concluded that the method is relatively simple to apply and has small intra-session and fair inter-session variability. Interesting gender differences were observed.

  3. 77 FR 58209 - Fourth Meeting: RTCA Special Committee 226, Audio Systems and Equipment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-19

    ... discussion on TSO-C99A (Oxygen Mask Communication) Continue discussion on the following: Risks of usage of... manufacturers Addition of noise test requirement to the vibration test variable nature of Oxygen Mask Microphone...

  4. Undersampling strategies for compressed sensing accelerated MR spectroscopic imaging

    NASA Astrophysics Data System (ADS)

    Vidya Shankar, Rohini; Hu, Houchun Harry; Bikkamane Jayadev, Nutandev; Chang, John C.; Kodibagkar, Vikram D.

    2017-03-01

    Compressed sensing (CS) can accelerate magnetic resonance spectroscopic imaging (MRSI), facilitating its widespread clinical integration. The objective of this study was to assess the effect of different undersampling strategy on CS-MRSI reconstruction quality. Phantom data were acquired on a Philips 3 T Ingenia scanner. Four types of undersampling masks, corresponding to each strategy, namely, low resolution, variable density, iterative design, and a priori were simulated in Matlab and retrospectively applied to the test 1X MRSI data to generate undersampled datasets corresponding to the 2X - 5X, and 7X accelerations for each type of mask. Reconstruction parameters were kept the same in each case(all masks and accelerations) to ensure that any resulting differences can be attributed to the type of mask being employed. The reconstructed datasets from each mask were statistically compared with the reference 1X, and assessed using metrics like the root mean square error and metabolite ratios. Simulation results indicate that both the a priori and variable density undersampling masks maintain high fidelity with the 1X up to five-fold acceleration. The low resolution mask based reconstructions showed statistically significant differences from the 1X with the reconstruction failing at 3X, while the iterative design reconstructions maintained fidelity with the 1X till 4X acceleration. In summary, a pilot study was conducted to identify an optimal sampling mask in CS-MRSI. Simulation results demonstrate that the a priori and variable density masks can provide statistically similar results to the fully sampled reference. Future work would involve implementing these two masks prospectively on a clinical scanner.

  5. Aided speech recognition in single-talker competition by elderly hearing-impaired listeners

    NASA Astrophysics Data System (ADS)

    Coughlin, Maureen; Humes, Larry

    2004-05-01

    This study examined the speech-identification performance in one-talker interference conditions that increased in complexity while audibility was ensured over a wide bandwidth (200-4000 Hz). Factorial combinations of three independent variables were used to vary the amount of informational masking. These variables were: (1) competition playback direction (forward or reverse); (2) gender match between target and competition talkers (same or different); and (3) target talker uncertainty (one of three possible talkers from trial to trial). Four groups of listeners, two elderly hearing-impaired groups differing in age (65-74 and 75-84 years) and two young normal-hearing groups, were tested. One of the groups of young normal-hearing listeners was tested under acoustically equivalent test conditions and one was tested under perceptually equivalent test conditions. The effect of each independent variable on speech-identification performance and informational masking was generally consistent with expectations. Group differences in the observed informational masking were most pronounced for the oldest group of hearing-impaired listeners. The eight measures of speech-identification performance were found to be strongly correlated with one another, and individual differences in speech understanding performance among the elderly were found to be associated with age and level of education. [Work supported, in part, by NIA.

  6. Feedforward and feedback control in apraxia of speech: effects of noise masking on vowel production.

    PubMed

    Maas, Edwin; Mailend, Marja-Liisa; Guenther, Frank H

    2015-04-01

    This study was designed to test two hypotheses about apraxia of speech (AOS) derived from the Directions Into Velocities of Articulators (DIVA) model (Guenther et al., 2006): the feedforward system deficit hypothesis and the feedback system deficit hypothesis. The authors used noise masking to minimize auditory feedback during speech. Six speakers with AOS and aphasia, 4 with aphasia without AOS, and 2 groups of speakers without impairment (younger and older adults) participated. Acoustic measures of vowel contrast, variability, and duration were analyzed. Younger, but not older, speakers without impairment showed significantly reduced vowel contrast with noise masking. Relative to older controls, the AOS group showed longer vowel durations overall (regardless of masking condition) and a greater reduction in vowel contrast under masking conditions. There were no significant differences in variability. Three of the 6 speakers with AOS demonstrated the group pattern. Speakers with aphasia without AOS did not differ from controls in contrast, duration, or variability. The greater reduction in vowel contrast with masking noise for the AOS group is consistent with the feedforward system deficit hypothesis but not with the feedback system deficit hypothesis; however, effects were small and not present in all individual speakers with AOS. Theoretical implications and alternative interpretations of these findings are discussed.

  7. Feedforward and Feedback Control in Apraxia of Speech: Effects of Noise Masking on Vowel Production

    PubMed Central

    Mailend, Marja-Liisa; Guenther, Frank H.

    2015-01-01

    Purpose This study was designed to test two hypotheses about apraxia of speech (AOS) derived from the Directions Into Velocities of Articulators (DIVA) model (Guenther et al., 2006): the feedforward system deficit hypothesis and the feedback system deficit hypothesis. Method The authors used noise masking to minimize auditory feedback during speech. Six speakers with AOS and aphasia, 4 with aphasia without AOS, and 2 groups of speakers without impairment (younger and older adults) participated. Acoustic measures of vowel contrast, variability, and duration were analyzed. Results Younger, but not older, speakers without impairment showed significantly reduced vowel contrast with noise masking. Relative to older controls, the AOS group showed longer vowel durations overall (regardless of masking condition) and a greater reduction in vowel contrast under masking conditions. There were no significant differences in variability. Three of the 6 speakers with AOS demonstrated the group pattern. Speakers with aphasia without AOS did not differ from controls in contrast, duration, or variability. Conclusion The greater reduction in vowel contrast with masking noise for the AOS group is consistent with the feedforward system deficit hypothesis but not with the feedback system deficit hypothesis; however, effects were small and not present in all individual speakers with AOS. Theoretical implications and alternative interpretations of these findings are discussed. PMID:25565143

  8. A Variable-Selection Heuristic for K-Means Clustering.

    ERIC Educational Resources Information Center

    Brusco, Michael J.; Cradit, J. Dennis

    2001-01-01

    Presents a variable selection heuristic for nonhierarchical (K-means) cluster analysis based on the adjusted Rand index for measuring cluster recovery. Subjected the heuristic to Monte Carlo testing across more than 2,200 datasets. Results indicate that the heuristic is extremely effective at eliminating masking variables. (SLD)

  9. [Patients' reaction to pharmacists wearing a mask during their consultations].

    PubMed

    Tamura, Eri; Kishimoto, Keiko; Fukushima, Noriko

    2013-01-01

      This study sought to determine the effect of pharmacists wearing a mask on the consultation intention of patients who do not have a trusting relationship with the pharmacists. We conducted a questionnaire survey of customers at a Tokyo drugstore in August 2012. Subjects answered a questionnaire after watching two medical teaching videos, one in which the pharmacist was wearing a mask and the other in which the pharmacist was not wearing a mask. Data analysis was performed using a paired t-test and multiple logistic regression. The paired t-test revealed a significant difference in 'Maintenance Problem' between the two pharmacist situations. After excluding factors not associated with wearing a mask, multiple logistic regression analysis identified three independent variables with a significant effect on participants not wanting to consult with a pharmacist wearing a mask. Positive factors were 'active-inactive' and 'frequency mask use', a negative factor was 'age'. Our study has shown that pharmacists wearing a mask may be a factor that prevents patients from consulting with pharmacist. Those patients whose intention to consult might be affected by the pharmacists wearing a mask tended to be younger, to have no habit of wearing masks preventively themselves, and to form a negative opinion of such pharmacists. Therefore, it was estimated that pharmacists who wear masks need to provide medical education by asking questions more positively than when they do not wear a mask in order to prevent the patient worrying about oneself.

  10. Influence of mask type and mask position on the effectiveness of bag-mask ventilation in a neonatal manikin.

    PubMed

    Deindl, Philipp; O'Reilly, Megan; Zoller, Katharina; Berger, Angelika; Pollak, Arnold; Schwindt, Jens; Schmölzer, Georg M

    2014-01-01

    Anatomical face mask with an air cushion rim might be placed accidentally in a false orientation on the newborn's face or filled with various amounts of air during neonatal resuscitation. Both false orientation as well as variable filling may reduce a tight seal and therefore hamper effective positive pressure ventilation (PPV). We aimed to measure the influence of mask type and mask position on the effectiveness of PPV. Twenty neonatal staff members delivered PPV to a modified, leak-free manikin. Resuscitation parameters were recorded using a self-inflatable bag PPV with an Intersurgical anatomical air cushion rim face mask (IS) and a size 0/1 Laerdal round face mask. Three different positions of the IS were tested: correct position, 90° and 180° rotation in reference to the midline of the face. IS masks in each correct position on the face but with different inflation of the air cushion (empty, 10, 20 and 30 mL). Mask leak was similar with mask rotation to either 90° or 180° but significantly increased from 27 (13-73) % with an adequate filled IS mask compared to 52 (16-83) % with an emptied air cushion rim. Anatomical-shaped face mask had similar mask leaks compared to round face mask. A wrongly positioned anatomical-shaped mask does not influence mask leak. Mask leak significantly increased once the air cushion rim was empty, which may cause failure in mask PPV.

  11. Cross sectional: perception of children from public and private schools regarding the esthetic impact of different types of face masks.

    PubMed

    Pithon, Matheus Melo; Ferraz, Caio Sousa; de Oliveira, Gabriel Couto; Dos Santos, Adrielle Mangabeira; Couto, Felipe Santos; da Silva Coqueiro, Raildo; Dos Santos, Rogério Lacerda

    2013-01-01

    The purpose was to evaluate the esthetic perception among children from public and private schools regarding the use of different types of face masks. Six different types of orthopedic face masks made from images of the same patient were evaluated. Initially, the images were standardized with the help of Adobe Photoshop software. The variable considered was type of mask: (A) Delaire with facebow; (B) Petit; (C) Delaire; (D)Turley; (E) Hickham; and (F) Sky Hook. The images were printed on photographic paper and incorporated into a specific personalized questionnaire that was distributed to 7- to 10-year-olds attending public and private schools (n=120). The data obtained were compared via chi-square, Fisher's exact tests, Mann-Whitney and Spearman's tests. The proportion of participants who chose image A as the best was significantly higher (P<.05) compared to the other masks. Images B and F were chosen as the worst, without a significant difference between them (P>.05). The mean scores between groups were not significantly correlated between private vs public schoolchildren (r=0.32) and between boys and girls (r=0.41). Delaire face mask with facebow was chosen as the most attractive, and the Petit and Sky Hook face masks were voted the least attractive.

  12. Dead space variability of face masks for valved holding chambers.

    PubMed

    Amirav, Israel; Newhouse, Michael T

    2008-03-01

    Valved holding chambers with masks are commonly used to deliver inhaled medications to young children with asthma. Optimal mask properties such as their dead space volume have received little attention. The smaller the mask the more likely it is that a greater proportion of the dose in the VHC will be inhaled with each breath, thus speeding VHC emptying and improving overall aerosol delivery efficiency and dose. Masks may have different DSV and thus different performance. To compare both physical dead space and functional dead space of different face masks under various applied pressures. The DSV of three commonly used face masks of VHCs was measured by water displacement both under various pressures (to simulate real-life application, dynamic DSV) and under no pressure (static DSV). There was a great variability of both static and dynamic dead space among various face mask for VHCs, which is probably related to their flexibility. Different masks have different DSV characteristics. This variability should be taken into account when comparing the clinical efficacy of various VHCs.

  13. Scanner qualification with IntenCD based reticle error correction

    NASA Astrophysics Data System (ADS)

    Elblinger, Yair; Finders, Jo; Demarteau, Marcel; Wismans, Onno; Minnaert Janssen, Ingrid; Duray, Frank; Ben Yishai, Michael; Mangan, Shmoolik; Cohen, Yaron; Parizat, Ziv; Attal, Shay; Polonsky, Netanel; Englard, Ilan

    2010-03-01

    Scanner introduction into the fab production environment is a challenging task. An efficient evaluation of scanner performance matrices during factory acceptance test (FAT) and later on during site acceptance test (SAT) is crucial for minimizing the cycle time for pre and post production-start activities. If done effectively, the matrices of base line performance established during the SAT are used as a reference for scanner performance and fleet matching monitoring and maintenance in the fab environment. Key elements which can influence the cycle time of the SAT, FAT and maintenance cycles are the imaging, process and mask characterizations involved with those cycles. Discrete mask measurement techniques are currently in use to create across-mask CDU maps. By subtracting these maps from their final wafer measurement CDU map counterparts, it is possible to assess the real scanner induced printed errors within certain limitations. The current discrete measurement methods are time consuming and some techniques also overlook mask based effects other than line width variations, such as transmission and phase variations, all of which influence the final printed CD variability. Applied Materials Aera2TM mask inspection tool with IntenCDTM technology can scan the mask at high speed, offer full mask coverage and accurate assessment of all masks induced source of errors simultaneously, making it beneficial for scanner qualifications and performance monitoring. In this paper we report on a study that was done to improve a scanner introduction and qualification process using the IntenCD application to map the mask induced CD non uniformity. We will present the results of six scanners in production and discuss the benefits of the new method.

  14. Preserved subliminal processing and impaired conscious access in schizophrenia

    PubMed Central

    Del Cul, Antoine; Dehaene, Stanislas; Leboyer, Marion

    2006-01-01

    Background Studies of visual backward masking have frequently revealed an elevated masking threshold in schizophrenia. This finding has frequently been interpreted as indicating a low-level visual deficit. However, more recent models suggest that masking may also involve late and higher-level integrative processes, while leaving intact early “bottom-up” visual processing. Objectives We tested the hypothesis that the backward masking deficit in schizophrenia corresponds to a deficit in the late stages of conscious perception, whereas the subliminal processing of masked stimuli is fully preserved. Method 28 patients with schizophrenia and 28 normal controls performed two backward-masking experiments. We used Arabic digits as stimuli and varied quasi-continuously the interval with a subsequent mask, thus allowing us to progressively “unmask” the stimuli. We finely quantified their degree of visibility using both objective and subjective measures to evaluate the threshold duration for access to consciousness. We also studied the priming effect caused by the variably masked numbers on a comparison task performed on a subsequently presented and highly visible target number. Results The threshold delay between digit and mask necessary for the conscious perception of the masked stimulus was longer in patients compared to control subjects. This higher consciousness threshold in patients was confirmed by an objective and a subjective measure, and both measures were highly correlated for patients as well as for controls. However, subliminal priming of masked numbers was effective and identical in patients compared to controls. Conclusions Access to conscious report of masked stimuli is impaired in schizophrenia, while fast bottom-up processing of the same stimuli, as assessed by subliminal priming, is preserved. These findings suggest a high-level origin of the masking deficit in schizophrenia, although they leave open for further research its exact relation to previously identified bottom-up visual processing abnormalities. PMID:17146006

  15. Extension of optical lithography by mask-litho integration with computational lithography

    NASA Astrophysics Data System (ADS)

    Takigawa, T.; Gronlund, K.; Wiley, J.

    2010-05-01

    Wafer lithography process windows can be enlarged by using source mask co-optimization (SMO). Recently, SMO including freeform wafer scanner illumination sources has been developed. Freeform sources are generated by a programmable illumination system using a micro-mirror array or by custom Diffractive Optical Elements (DOE). The combination of freeform sources and complex masks generated by SMO show increased wafer lithography process window and reduced MEEF. Full-chip mask optimization using source optimized by SMO can generate complex masks with small variable feature size sub-resolution assist features (SRAF). These complex masks create challenges for accurate mask pattern writing and low false-defect inspection. The accuracy of the small variable-sized mask SRAF patterns is degraded by short range mask process proximity effects. To address the accuracy needed for these complex masks, we developed a highly accurate mask process correction (MPC) capability. It is also difficult to achieve low false-defect inspections of complex masks with conventional mask defect inspection systems. A printability check system, Mask Lithography Manufacturability Check (M-LMC), is developed and integrated with 199-nm high NA inspection system, NPI. M-LMC successfully identifies printable defects from all of the masses of raw defect images collected during the inspection of a complex mask. Long range mask CD uniformity errors are compensated by scanner dose control. A mask CD uniformity error map obtained by mask metrology system is used as input data to the scanner. Using this method, wafer CD uniformity is improved. As reviewed above, mask-litho integration technology with computational lithography is becoming increasingly important.

  16. Particulate face masks for protection against airborne pathogens - one size does not fit all: an observational study.

    PubMed

    Winter, Susan; Thomas, Jane H; Stephens, Dianne P; Davis, Joshua S

    2010-03-01

    To determine the proportion of hospital staff who pass fit tests with each of three commonly used particulate face masks, and factors influencing preference and fit test results. Observational study. 50 healthy hospital staff volunteers in an 18-bed general intensive care unit in an Australian teaching hospital. Participants were administered a questionnaire about mask use and their preferred mask and underwent qualitative fit-testing with each of three different particulate masks: Kimberly-Clark Tecnol FluidShield N95 particulate filter respirator (KC), 3M Flat Fold 9320 particulate respirator and 3M 8822 particulate respirator with exhalation valve. Participants who failed fittesting were trained in correct mask donning, and fittesting was repeated. Proportion of participants who passed the fit test for each mask and the effect of training. The proportion of participants who passed a fit test was low for all three masks tested (KC, 16%; flat fold, 28%; and valved, 34%). Rates improved after training: the first mask tested fitted in 18% of participants pre-training and 40% post-training (P = 0.02). None of the masks fitted for 28% of participants. There were no significant predictors of fit-test results. A large proportion of individuals failed a fit test with any given mask, and we were not able to identify any factors that predicted mask fit in individuals. Training on mask use improved the rates of adequate fit. Hospitals should carry a range of P2 masks, and should conduct systematic P2 mask training and fit-testing programs for all staff potentially exposed to airborne pathogens.

  17. Football Face-Mask Removal With a Cordless Screwdriver on Helmets Used for at Least One Season of Play

    PubMed Central

    Decoster, Laura C; Shirley, Chandra P; Swartz, Erik E

    2005-01-01

    Context: The Inter-Association Task Force for the Appropriate Care of the Spine-Injured Athlete recommends leaving a football player's helmet in place and removing the face mask from the helmet “as quickly as possible and with as little movement of the head and neck as possible.” Although 2 groups have studied face-mask removal from new equipment, to our knowledge no researchers have investigated equipment that has been previously used. A full season of play may have a significant effect on football equipment and its associated hardware. Countless impacts, weather, playing surfaces, sweat, and other unforeseen or unknown variables might make the face-mask removal process more difficult on equipment that has been used. Objective: To determine the percentage of face masks that we could unscrew, with a cordless screwdriver, from football helmets used for a full season. Design: Cross-sectional. Setting: Three New England high schools. Patients or Other Participants: All football helmets used at 3 local high schools were tested (n = 222, mean games, 9.7 ± 1.2; mean practice weeks, 13.7 ± 1.2). Intervention(s): Each helmet was secured to a board, and a cordless screwdriver was used to attempt to remove all 4 screws attaching the face mask to the helmet. Main Outcome Measure(s): Variables included overall success or failure, time required for face-mask removal, and success by screw location. Data were analyzed with χ2, analysis of variance, and Tamhane post hoc tests. Results: Overall, 832 (94%) of 885 screws were unscrewed, and 183 (82.4%) of 222 face masks were removed. Mean removal time was 26.9 ± 5.83 seconds. Face-mask removal success was significantly different between school 1 (24 [52.2%] of 46) and schools 2 (84 [91.3%] of 92) and 3 (75 [89.3%] of 84; F2,219 = 24.608; P < .001). The removal success rate was significantly higher at top screws (98%) than at screws adjacent to ear holes (90%) (P < .001). Conclusions: Based on our results and previous findings that demonstrated quicker access time and reduced head movement associated with the use of the screwdriver compared with cutting tools, the former may be a good tool for face-mask removal. However, an appropriate cutting tool must be immediately available should the screwdriver fail. Helmet hardware adjacent to ear holes was more vulnerable to failure, perhaps because it is protected by less padding than the top hardware. Possible causes of the higher failure rate at school 1 are the use of hardware materials subject to rust and corrosion and differences in helmet brand; these areas warrant future research and rules consideration. PMID:16284636

  18. Development for 2D pattern quantification method on mask and wafer

    NASA Astrophysics Data System (ADS)

    Matsuoka, Ryoichi; Mito, Hiroaki; Toyoda, Yasutaka; Wang, Zhigang

    2010-03-01

    We have developed the effective method of mask and silicon 2-dimensional metrology. The aim of this method is evaluating the performance of the silicon corresponding to Hotspot on a mask. The method adopts a metrology management system based on DBM (Design Based Metrology). This is the high accurate contouring created by an edge detection algorithm used in mask CD-SEM and silicon CD-SEM. Currently, as semiconductor manufacture moves towards even smaller feature size, this necessitates more aggressive optical proximity correction (OPC) to drive the super-resolution technology (RET). In other words, there is a trade-off between highly precise RET and mask manufacture, and this has a big impact on the semiconductor market that centers on the mask business. 2-dimensional Shape quantification is important as optimal solution over these problems. Although 1-dimensional shape measurement has been performed by the conventional technique, 2-dimensional shape management is needed in the mass production line under the influence of RET. We developed the technique of analyzing distribution of shape edge performance as the shape management technique. On the other hand, there is roughness in the silicon shape made from a mass-production line. Moreover, there is variation in the silicon shape. For this reason, quantification of silicon shape is important, in order to estimate the performance of a pattern. In order to quantify, the same shape is equalized in two dimensions. And the method of evaluating based on the shape is popular. In this study, we conducted experiments for averaging method of the pattern (Measurement Based Contouring) as two-dimensional mask and silicon evaluation technique. That is, observation of the identical position of a mask and a silicon was considered. It is possible to analyze variability of the edge of the same position with high precision. The result proved its detection accuracy and reliability of variability on two-dimensional pattern (mask and silicon) and is adaptable to following fields of mask quality management. - Estimate of the correlativity of shape variability and a process margin. - Determination of two-dimensional variability of pattern. - Verification of the performance of the pattern of various kinds of Hotspots. In this report, we introduce the experimental results and the application. We expect that the mask measurement and the shape control on mask production will make a huge contribution to mask yield-enhancement and that the DFM solution for mask quality control process will become much more important technology than ever. It is very important to observe the shape of the same location of Design, Mask, and Silicon in such a viewpoint.

  19. Technique for ship/wake detection

    DOEpatents

    Roskovensky, John K [Albuquerque, NM

    2012-05-01

    An automated ship detection technique includes accessing data associated with an image of a portion of Earth. The data includes reflectance values. A first portion of pixels within the image are masked with a cloud and land mask based on spectral flatness of the reflectance values associated with the pixels. A given pixel selected from the first portion of pixels is unmasked when a threshold number of localized pixels surrounding the given pixel are not masked by the cloud and land mask. A spatial variability image is generated based on spatial derivatives of the reflectance values of the pixels which remain unmasked by the cloud and land mask. The spatial variability image is thresholded to identify one or more regions within the image as possible ship detection regions.

  20. A Fast Turn-Around Facility for Very Large Scale Integration (VLSI)

    DTIC Science & Technology

    1982-06-01

    statistics determination, the first test mask set will use the MATRIX chip design which was recently developed here at Stanford. This chip provides...reached when the basewidth is reduced to zero. Such devices, variably known as depleted- base transistors or bipolar static-induction transitors , have been

  1. Model-based virtual VSB mask writer verification for efficient mask error checking and optimization prior to MDP

    NASA Astrophysics Data System (ADS)

    Pack, Robert C.; Standiford, Keith; Lukanc, Todd; Ning, Guo Xiang; Verma, Piyush; Batarseh, Fadi; Chua, Gek Soon; Fujimura, Akira; Pang, Linyong

    2014-10-01

    A methodology is described wherein a calibrated model-based `Virtual' Variable Shaped Beam (VSB) mask writer process simulator is used to accurately verify complex Optical Proximity Correction (OPC) and Inverse Lithography Technology (ILT) mask designs prior to Mask Data Preparation (MDP) and mask fabrication. This type of verification addresses physical effects which occur in mask writing that may impact lithographic printing fidelity and variability. The work described here is motivated by requirements for extreme accuracy and control of variations for today's most demanding IC products. These extreme demands necessitate careful and detailed analysis of all potential sources of uncompensated error or variation and extreme control of these at each stage of the integrated OPC/ MDP/ Mask/ silicon lithography flow. The important potential sources of variation we focus on here originate on the basis of VSB mask writer physics and other errors inherent in the mask writing process. The deposited electron beam dose distribution may be examined in a manner similar to optical lithography aerial image analysis and image edge log-slope analysis. This approach enables one to catch, grade, and mitigate problems early and thus reduce the likelihood for costly long-loop iterations between OPC, MDP, and wafer fabrication flows. It moreover describes how to detect regions of a layout or mask where hotspots may occur or where the robustness to intrinsic variations may be improved by modification to the OPC, choice of mask technology, or by judicious design of VSB shots and dose assignment.

  2. Method of forming a variable width channel

    NASA Technical Reports Server (NTRS)

    Andrews, James T. (Inventor)

    1989-01-01

    A method of forming a channel of varying width in a body comprises the steps of forming a plurality of masking elements having an opening therethrough intersecting a plurality of the elements on a surface of the body, partially flowing the elements into the opening to form a masking pattern having a variable width opening therethrough, and removing portions of the exposed body to form the channel with a sidewall having a surface contour corresponding to an edge of the masking pattern.

  3. 42 CFR 84.252 - Gas masks; requirements and tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Gas masks; requirements and tests. 84.252 Section... Respirators § 84.252 Gas masks; requirements and tests. (a) Except for the tests prescribed in § 84.126, the minimum requirements and performance tests for gas masks, prescribed in Subpart I of this part, are...

  4. Body temperature variability (Part 2): masking influences of body temperature variability and a review of body temperature variability in disease.

    PubMed

    Kelly, Gregory S

    2007-03-01

    This is the second of a two-part review on body temperature variability. Part 1 discussed historical and modern findings on average body temperatures. It also discussed endogenous sources of temperature variability, including variations caused by site of measurement; circadian, menstrual, and annual biological rhythms; fitness; and aging. Part 2 reviews the effects of exogenous masking agents - external factors in the environment, diet, or lifestyle that can be a significant source of body temperature variability. Body temperature variability findings in disease states are also reviewed.

  5. Gestalt grouping and common onset masking.

    PubMed

    Kahan, Todd A; Mathis, Katherine M

    2002-11-01

    A four-dot mask that surrounds and is presented simultaneously with a briefly presented target will reduce a person's ability to identity that target if the mask persists beyond target offset and attention is divided (Enns & Di Lollo, 1997, 2000). This masking effect, referred to as common onset masking, reflects reentrant processing in the visual system and can best be explained with a theory of object substitution (Di Lollo, Enns, & Rensink, 2000). In the present experiments, we investigated whether Gestalt grouping variables would influence the strength of common onset masking. The results indicated that (1) masking was impervious to grouping by form, similarity of color, position, luminance polarity, and common region and (2) masking increased with the number of elements in the masking display.

  6. Suitability of E-tongue Sensors to Assess Taste-Masking of Pediatric Liquids by Different Beverages Considering Their Physico-chemical Properties.

    PubMed

    Immohr, Laura Isabell; Hedfeld, Claas; Lang, Artur; Pein-Hackelbusch, Miriam

    2017-02-01

    Manipulation of liquid oral drugs by mixing them into foodstuff is a common procedure for taste-masking of OTC pharmaceuticals when administered to children. However, the taste-masking capability of such application media is not systematically evaluated, and recommendations for suitable media are hardly published. In this study, a sensor array of commercially available and self-developed electronic tongue sensors was employed to assess the taste-masking efficiency of eight different beverages (tap water, apple juice, carrot juice, fennel tea, fruit tea, milk, cocoa, and Alete meal to drink) on the OTC pharmaceuticals Ambroxol-ratiopharm®, Cetirizin AL, and Laxoberal® by multivariate data analysis. The Euclidean distances between each pure application medium and its corresponding drug mixture were used as an indicator for the taste-masking efficiency and correlated to the physico-chemical properties of the beverages. Thus, the pH value, the viscosity, as well as the fat and sugar content of the beverages were included, whereas only the viscosity appeared to be insignificant in all cases. The sugar content as well as the fat content and pH value emerged to be a significant variable in taste-masking efficiency for some of the tested drug products. It was shown that the applied electronic tongue sensors were capable to demonstrate the impact of the physico-chemical properties of the application media on their taste-masking capacity regardless of their non-selectivity towards these characteristics.

  7. Optimizing the taste-masked formulation of acetaminophen using sodium caseinate and lecithin by experimental design.

    PubMed

    Hoang Thi, Thanh Huong; Lemdani, Mohamed; Flament, Marie-Pierre

    2013-09-10

    In a previous study of ours, the association of sodium caseinate and lecithin was demonstrated to be promising for masking the bitterness of acetaminophen via drug encapsulation. The encapsulating mechanisms were suggested to be based on the segregation of multicomponent droplets occurring during spray-drying. The spray-dried particles delayed the drug release within the mouth during the early time upon administration and hence masked the bitterness. Indeed, taste-masking is achieved if, within the frame of 1-2 min, drug substance is either not released or the released amount is below the human threshold for identifying its bad taste. The aim of this work was (i) to evaluate the effect of various processing and formulation parameters on the taste-masking efficiency and (ii) to determine the optimal formulation for optimal taste-masking effect. Four investigated input variables included inlet temperature (X1), spray flow (X2), sodium caseinate amount (X3) and lecithin amount (X4). The percentage of drug release amount during the first 2 min was considered as the response variable (Y). A 2(4)-full factorial design was applied and allowed screening for the most influential variables i.e. sodium caseinate amount and lecithin amount. Optimizing these two variables was therefore conducted by a simplex approach. The SEM and DSC results of spray-dried powder prepared under optimal conditions showed that drug seemed to be well encapsulated. The drug release during the first 2 min significantly decreased, 7-fold less than the unmasked drug particles. Therefore, the optimal formulation that performed the best taste-masking effect was successfully achieved. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Effectiveness of face masks used to protect Beijing residents against particulate air pollution.

    PubMed

    Cherrie, John W; Apsley, Andrew; Cowie, Hilary; Steinle, Susanne; Mueller, William; Lin, Chun; Horwell, Claire J; Sleeuwenhoek, Anne; Loh, Miranda

    2018-06-01

    Many residents in Beijing use disposable face masks in an attempt to protect their health from high particulate matter (PM) concentrations. Retail masks may be certified to local or international standards, but their real-life performance may not confer the exposure reduction potential that is marketed. This study aimed to evaluate the effectiveness of a range of face masks that are commercially available in China. Nine masks claiming protection against fine PM (PM 2.5 ) were purchased from consumer outlets in Beijing. The masks' filtration efficiency was tested by drawing airborne diesel exhaust through a section of the material and measuring the PM 2.5 and black carbon (BC) concentrations upstream and downstream of the filtering medium. Four masks were selected for testing on volunteers. Volunteers were exposed to diesel exhaust inside an experimental chamber while performing sedentary tasks and active tasks. BC concentrations were continuously monitored inside and outside the mask. The mean per cent penetration for each mask material ranged from 0.26% to 29%, depending on the flow rate and mask material. In the volunteer tests, the average total inward leakage (TIL) of BC ranged from 3% to 68% in the sedentary tests and from 7% to 66% in the active tests. Only one mask type tested showed an average TIL of less than 10%, under both test conditions. Many commercially available face masks may not provide adequate protection, primarily due to poor facial fit. Our results indicate that further attention should be given to mask design and providing evidence-based guidance to consumers. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  9. A respiratory mask for resting and exercising dogs.

    PubMed

    Stavert, D M; Reischl, P; O'Loughlin, B J

    1982-02-01

    A respiratory face mask has been developed for use with unsedated beagles trained to run on a treadmill. The latex rubber mask, shaped to fit the animal's muzzle, incorporates two modified, commercially available, pulmonary valves for separating inspiratory and expiratory flows. The mask has a dead space of 30 cm3 and a flow resistance below 1 cmH2O . 1(-1) . s. The flexible mask is used to measure breath-by-breath respiratory variables over extended periods of time during rest and exercise.

  10. Short-term variability and nocturnal decline in ambulatory blood pressure in normotension, white-coat hypertension, masked hypertension and sustained hypertension: a population-based study of older individuals in Spain.

    PubMed

    Gijón-Conde, Teresa; Graciani, Auxiliadora; López-García, Esther; Guallar-Castillón, Pilar; García-Esquinas, Esther; Rodríguez-Artalejo, Fernando; Banegas, José R

    2017-06-01

    Blood pressure (BP) variability and nocturnal decline in blood pressure are associated with cardiovascular outcomes. However, little is known about whether these indexes are associated with white-coat and masked hypertension. We performed a cross-sectional analysis of 1047 community-dwelling individuals aged ⩾60 years in Spain in 2012. Three observer-measured home BPs and 24-h ambulatory blood pressure monitoring (ABPM) were performed under standardized conditions. BP variability was defined as BP s.d. and coefficient of variation. Differences in BP variability and nocturnal BP decrease between groups were adjusted for sociodemographic and clinical covariates using generalized linear models. Of the cohort, 21.7% had white-coat hypertension, 7.0% had masked hypertension, 21.4% had sustained hypertension, and 49.9% were normotensive. Twenty-four hour, daytime and night-time systolic BP s.d. and coefficients of variation were significantly higher in subjects with white-coat hypertension than those with normotension (P<0.05) and were similar to subjects with sustained hypertension. In untreated subjects, 24-h but not daytime or night-time BP variability indexes were significantly higher in subjects with white-coat hypertension than in those with normotension (P<0.05). Percentage decrease in nocturnal systolic and diastolic BP was greatest in the white-coat hypertension group and lowest in the masked hypertension group in all patients and untreated patients (P<0.05). Lack of nocturnal decline in systolic blood pressure was observed in 70.2% of subjects with normotension, 57.8% of subjects with white-coat hypertension, 78.1% of subjects with masked hypertension, and 72.2% of subjects with sustained hypertension (P<0.001). In conclusion, 24-h BP variability was higher in subjects with white-coat hypertension and blunted nocturnal BP decrease was observed more frequently in subjects with masked hypertension. These findings may help to explain the reports of increased cardiovascular risk in patients with white-coat hypertension and poor prognosis in those with masked hypertension, highlighting the importance of ABPM.

  11. Inter- and intrafraction patient positioning uncertainties for intracranial radiotherapy: a study of four frameless, thermoplastic mask-based immobilization strategies using daily cone-beam CT.

    PubMed

    Tryggestad, Erik; Christian, Matthew; Ford, Eric; Kut, Carmen; Le, Yi; Sanguineti, Giuseppe; Song, Danny Y; Kleinberg, Lawrence

    2011-05-01

    To determine whether frameless thermoplastic mask-based immobilization is adequate for image-guided cranial radiosurgery. Cone-beam CT localization data from patients with intracranial tumors were studied using daily pre- and posttreatment scans. The systems studied were (1) Type-S IMRT (head only) mask (Civco) with head cushion; (2) Uni-Frame mask (Civco) with head cushion, coupled with a BlueBag body immobilizer (Medical Intelligence); (3) Type-S head and shoulder mask with head and shoulder cushion (Civco); (4) same as previous, coupled with a mouthpiece. The comparative metrics were translational shift magnitude and average rotation angle; systematic inter-, random inter-, and random intrafraction positioning error was computed. For strategies 1-4, respectively, the analysis for interfraction variability included data from 20, 9, 81, and 11 patients, whereas that for intrafraction variability included a subset of 7, 9, 16, and 8 patients. The results were compared for statistical significance using an analysis of variance test. Immobilization system 4 provided the best overall accuracy and stability. The mean interfraction translational shifts (± SD) were 2.3 (± 1.4), 2.2 (± 1.1), 2.7 (± 1.5), and 2.1 (± 1.0) mm whereas intrafraction motion was 1.1 (± 1.2), 1.1 (± 1.1), 0.7 (± 0.9), and 0.7 (± 0.8) mm for devices 1-4, respectively. No significant correlation between intrafraction motion and treatment time was evident, although intrafraction motion was not purely random. We find that all frameless thermoplastic mask systems studied are viable solutions for image-guided intracranial radiosurgery. With daily pretreatment corrections, symmetric PTV margins of 1 mm would likely be adequate if ideal radiation planning and targeting systems were available. Copyright © 2011 Elsevier Inc. All rights reserved.

  12. A novel adaptive scoring system for segmentation validation with multiple reference masks

    NASA Astrophysics Data System (ADS)

    Moltz, Jan H.; Rühaak, Jan; Hahn, Horst K.; Peitgen, Heinz-Otto

    2011-03-01

    The development of segmentation algorithms for different anatomical structures and imaging protocols is an important task in medical image processing. The validation of these methods, however, is often treated as a subordinate task. Since manual delineations, which are widely used as a surrogate for the ground truth, exhibit an inherent uncertainty, it is preferable to use multiple reference segmentations for an objective validation. This requires a consistent framework that should fulfill three criteria: 1) it should treat all reference masks equally a priori and not demand consensus between the experts; 2) it should evaluate the algorithmic performance in relation to the inter-reference variability, i.e., be more tolerant where the experts disagree about the true segmentation; 3) it should produce results that are comparable for different test data. We show why current state-of-the-art frameworks as the one used at several MICCAI segmentation challenges do not fulfill these criteria and propose a new validation methodology. A score is computed in an adaptive way for each individual segmentation problem, using a combination of volume- and surface-based comparison metrics. These are transformed into the score by relating them to the variability between the reference masks which can be measured by comparing the masks with each other or with an estimated ground truth. We present examples from a study on liver tumor segmentation in CT scans where our score shows a more adequate assessment of the segmentation results than the MICCAI framework.

  13. Testing the efficacy of homemade masks: would they protect in an influenza pandemic?

    PubMed

    Davies, Anna; Thompson, Katy-Anne; Giri, Karthika; Kafatos, George; Walker, Jimmy; Bennett, Allan

    2013-08-01

    This study examined homemade masks as an alternative to commercial face masks. Several household materials were evaluated for the capacity to block bacterial and viral aerosols. Twenty-one healthy volunteers made their own face masks from cotton t-shirts; the masks were then tested for fit. The number of microorganisms isolated from coughs of healthy volunteers wearing their homemade mask, a surgical mask, or no mask was compared using several air-sampling techniques. The median-fit factor of the homemade masks was one-half that of the surgical masks. Both masks significantly reduced the number of microorganisms expelled by volunteers, although the surgical mask was 3 times more effective in blocking transmission than the homemade mask. Our findings suggest that a homemade mask should only be considered as a last resort to prevent droplet transmission from infected individuals, but it would be better than no protection.

  14. Clustering Binary Data in the Presence of Masking Variables

    ERIC Educational Resources Information Center

    Brusco, Michael J.

    2004-01-01

    A number of important applications require the clustering of binary data sets. Traditional nonhierarchical cluster analysis techniques, such as the popular K-means algorithm, can often be successfully applied to these data sets. However, the presence of masking variables in a data set can impede the ability of the K-means algorithm to recover the…

  15. Automated evaluation of AIMS images: an approach to minimize evaluation variability

    NASA Astrophysics Data System (ADS)

    Dürr, Arndt C.; Arndt, Martin; Fiebig, Jan; Weiss, Samuel

    2006-05-01

    Defect disposition and qualification with stepper simulating AIMS tools on advanced masks of the 90nm node and below is key to match the customer's expectations for "defect free" masks, i.e. masks containing only non-printing design variations. The recently available AIMS tools allow for a large degree of automated measurements enhancing the throughput of masks and hence reducing cycle time - up to 50 images can be recorded per hour. However, this amount of data still has to be evaluated by hand which is not only time-consuming but also error prone and exhibits a variability depending on the person doing the evaluation which adds to the tool intrinsic variability and decreases the reliability of the evaluation. In this paper we present the results of an MatLAB based algorithm which automatically evaluates AIMS images. We investigate its capabilities regarding throughput, reliability and matching with handmade evaluation for a large variety of dark and clear defects and discuss the limitations of an automated AIMS evaluation algorithm.

  16. Masked Hypertension is Associated With Cognitive Decline in Geriatric Age-Geriatric MASked Hypertension and Cognition (G-MASH-cog) Study.

    PubMed

    Esme, Mert; Yavuz, Burcu Balam; Yavuz, Bunyamin; Asil, Serkan; Tuna Dogrul, Rana; Sumer, Fatih; Kilic, Mustafa Kemal; Kizilarslanoglu, Muhammet Cemal; Varan, Hacer Dogan; Sagir, Aykut; Balci, Cafer; Halil, Meltem; Cankurtaran, Mustafa

    2018-01-16

    Masked hypertension is described as high ambulatory blood pressure measurements (ABPM) where office blood pressure measurements are normal. Effect of hypertension on cognitive functions is well known. However, the effect of masked hypertension on cognitive functions is unclear. The aim of this study is to examine the relationship between masked hypertension and cognitive functions. One hundred-two normotensive patients admitted to the Geriatric Medicine outpatient clinic were included. Exclusion criteria were hypertension, dementia, major depression, and usage of antihypertensive medication. All patients underwent ABPM procedures and average daytime blood pressure, mean blood pressure at night and the 24-hour average blood pressure measurements were recorded. Comprehensive geriatric assessment tests and neuropsychological tests were administered. The diagnosis of masked hypertension was based on the definitions in the 2013 guideline of the European Society of Cardiology. Forty-four patients (43%) were diagnosed with masked hypertension. Patients with masked hypertension had significantly lower scores on Mini-Mental State Examination (MMSE) test, Quick Mild Cognitive Impairment Test (QMCI), and Categorical Fluency Test than the normotensive patients (p = .011; p = .046; and p = .004; respectively). Montreal Cognitive Assessment Scale test score was lower in masked hypertension, although this was not statistically significant. This study may indicate that geriatric patients with masked hypertension, compared to normotensive patients have decreased cognitive functions. Masked hypertension should be kept in mind while assessing older adults. When masked hypertension is detected, cognitive assessment is essential to diagnose possible cognitive dysfunction at early stage. © The Author 2017. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  17. Effectiveness of surgical masks against influenza bioaerosols.

    PubMed

    Makison Booth, C; Clayton, M; Crook, B; Gawn, J M

    2013-05-01

    Most surgical masks are not certified for use as respiratory protective devices (RPDs). In the event of an influenza pandemic, logistical and practical implications such as storage and fit testing will restrict the use of RPDs to certain high-risk procedures that are likely to generate large amounts of infectious bioaerosols. Studies have shown that in such circumstances increased numbers of surgical masks are worn, but the protection afforded to the wearer by a surgical mask against infectious aerosols is not well understood. To develop and apply a method for assessing the protection afforded by surgical masks against a bioaerosol challenge. A dummy test head attached to a breathing simulator was used to test the performance of surgical masks against a viral challenge. Several designs of surgical masks commonly used in the UK healthcare sector were evaluated by measuring levels of inert particles and live aerosolised influenza virus in the air, from in front of and behind each mask. Live influenza virus was measurable from the air behind all surgical masks tested. The data indicate that a surgical mask will reduce exposure to aerosolised infectious influenza virus; reductions ranged from 1.1- to 55-fold (average 6-fold), depending on the design of the mask. We describe a workable method to evaluate the protective efficacy of surgical masks and RPDs against a relevant aerosolised biological challenge. The results demonstrated limitations of surgical masks in this context, although they are to some extent protective. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  18. Optimal Mixtures of Test Types in Paired-Associate Learning (Sensory Information Processing). Final Report.

    ERIC Educational Resources Information Center

    Wolford, George

    Seven experiments were run to determine the precise nature of some of the variables which affect the processing of short-term visual information. In particular, retinal location, report order, processing order, lateral masking, and redundancy were studied along with the nature of the confusion errors which are made in the full report procedure.…

  19. Evaluating practical vs. theoretical inspection system capability with a new programmed defect test mask designed for 3X and 4X technology nodes

    NASA Astrophysics Data System (ADS)

    Glasser, Joshua; Pratt, Tim

    2008-10-01

    Programmed defect test masks serve the useful purpose of evaluating inspection system sensitivity and capability. It is widely recognized that when evaluating inspection system capability, it is important to understand the actual sensitivity of the inspection system in production; yet unfortunately we have observed that many test masks are a more accurate judge of theoretical sensitivity rather than real-world usable capability. Use of ineffective test masks leave the purchaser of inspection equipment open to the risks of over-estimating the capability of their inspection solution and overspecifying defect sensitivity to their customers. This can result in catastrophic yield loss for device makers. In this paper we examine some of the lithography-related technology advances which place an increasing burden on mask inspection complexity, such as MEEF, defect printability estimation, aggressive OPC, double patterning, and OPC jogs. We evaluate the key inspection system component contributors to successful mask inspection, including what can "go wrong" with these components. We designed and fabricated a test mask which both (a) more faithfully represents actual production use cases; and (b) stresses the key components of the inspection system. This mask's patterns represent 32nm, 36nm, and 45nm logic and memory technology including metal and poly like background patterns with programmed defects. This test mask takes into consideration requirements of advanced lithography, such as MEEF, defect printability, assist features, nearly-repetitive patterns, and data preparation. This mask uses patterns representative of 32nm, 36nm, and 45nm logic, flash, and DRAM technology. It is specifically designed to have metal and poly like background patterns with programmed defects. The mask is complex tritone and was designed for annular immersion lithography.

  20. Effectiveness of three just-in-time training modalities for N-95 mask fit testing.

    PubMed

    Jones, David; Stoler, Genevieve; Suyama, Joe

    2013-01-01

    To compare and contrast three different training modalities for fit testing N-95 respirator face masks. Block randomized interventional study. Urban university. Two hundred eighty-nine medical students. Students were randomly assigned to video, lecture, or slide show to evaluate the effectiveness of the methods for fit testing large groups of people. Ease of fit and success of fit for each instructional technique. Mask 1 was a Kimberly-Clark duckbill N-95 respirator mask, and mask 2 was a 3M™ carpenters N-95 respirator mask. "Ease of fit" was defined as the ability to successfully don a mask in less than 30 seconds. "Success of fit" was defined as the ability to correctly don a mask in one try. There were no statistical differences by training modality for either mask regarding ease of fit or success of fit. There were no differences among video presentation, small group demonstration, and self-directed slide show just-in-time training modalities for ease of fit or success of fit N-95 respirator mask fitting. Further study is needed to explore more effective fit training modalities.

  1. Occulting focal plane masks for Terrestrial Planet Finder Coronagraph: design, fabrication, simulations and test results

    NASA Technical Reports Server (NTRS)

    Balasubramanian, Kunjithapatham; Hoppe, Daniel J.; Halverson, Peter G.; Wilson, Daniel W.; Echternach, Pierre M.; Shi, Fang; Lowman, Andrew E.; Niessner, Albert F.; Trauger, John T.; Shaklan, Stuart B.

    2005-01-01

    Occulting focal plane masks for the Terrestrial Planet Finder Coronagraph (TPF-C) could be designed with continuous gray scale profile of the occulting pattern such as 1-sinc2 on a suitable material or with micron-scale binary transparent and opaque structures of metallic pattern on glass. We have designed, fabricated and tested both kinds of masks. The fundamental characteristics of such masks and initial test results from the High Contrast Imaging Test bed (HCIT) at JPL are presented.

  2. Method for correcting imperfections on a surface

    DOEpatents

    Sweatt, William C.; Weed, John W.

    1999-09-07

    A process for producing near perfect optical surfaces. A previously polished optical surface is measured to determine its deviations from the desired perfect surface. A multi-aperture mask is designed based on this measurement and fabricated such that deposition through the mask will correct the deviations in the surface to an acceptable level. Various mask geometries can be used: variable individual aperture sizes using a fixed grid for the apertures or fixed aperture sizes using a variable aperture spacing. The imperfections are filled in using a vacuum deposition process with a very thin thickness of material such as silicon monoxide to produce an amorphous surface that bonds well to a glass substrate.

  3. [Intensive care unit profesionals's knowledge about non invasive ventilation comparative analysis].

    PubMed

    Raurell-Torredà, M; Argilaga-Molero, E; Colomer-Plana, M; Ruiz-García, T; Galvany-Ferrer, A; González-Pujol, A

    2015-01-01

    The literature highlights the lack of noninvasive ventilation (NIV) protocols and the variability of the knowledge of NIV between intensive care units (ICU) and hospitals, so we want to compare NIV nurses's Knowledge from 4 multipurpose ICU and one surgical ICU. Multicenter, crosscutting, descriptive study in three university hospitals. The survey instrument was validated in a pilot test, and the calculated Kappa index was 0.9. Returning a completed survey is an indication of informed consent. Analysis by Chi square test. 117 responded (65%) nurses, 11±9.7 years of experience in ICU and 9.2±7.2 in use of NIV. One of the multipurpose ICU, was initiated NIV an average of 6 years later than the others (95% CI [3.3 to 8.6], P<.001). Only 23.1% of nurses would place a non-vented mask (with no exhalation port) by conventional ventilator, the rest any kind of face mask. 12.7% believed that the mask must be adjusted to the "2-finger" fit while 29% would seal the mask to the patient's face and cover the mask opening where air escapes to facilitate patient/ventilator synchronization. In the surgical ICU agitation identifies mostly as a complication of NIV compared with multipurpose UCIs (31.6% vs 1.8%, P<.001). 56.4% of nurses do not consider respiratory physiotherapy as nursing care, with no difference between units. Knowledge about types of interface is very dependent on the material of the unit. More training for complications of NIV as agitation and handling secretions it is necessary. Copyright © 2014 Elsevier España, S.L.U. y SEEIUC. All rights reserved.

  4. Facial and ocular deposition of nebulized budesonide: effects of face mask design.

    PubMed

    Harris, Keith W; Smaldone, Gerald C

    2008-02-01

    In vivo case reports and in vitro studies have indicated that aerosol therapy using face masks can result in drug deposition on the face and in the eyes, and that face mask design may affect drug delivery. To test different mask/nebulizer combinations for budesonide, a nebulized steroid used to treat pediatric patients with asthma. Using high-performance liquid chromatography, drug delivery (inhaled mass), facial, and ocular deposition of budesonide aerosols were studied in vitro using a ventilated face facsimile (tidal volume, 50 mL; rate, 25 breaths/min, duty cycle 0.4), a tight-fitting test mask, a standard commercial mask, and a prototype mask designed to optimize delivery by reducing particle inertia. Nebulizer insertion into the mask (front loaded vs bottom loaded) was also tested. Particle size was measured by cascade impaction. Pari LC Plus (PARI Respiratory Equipment; Midlothian, VA) and MistyNeb (Allegiance; McGaw Park, IL) nebulizers were tested. Inhaled mass for tight-fitting and prototype masks was similar (13.2 +/- 1.85% vs 14.4 +/- 0.67% [percentage of nebulizer charge], p = 0.58) and significantly greater than for the commercial mask (3.03 +/- 0.26%, p = 0.005). Mask insertion of nebulizer was a key factor (inhaled mass: front loaded vs bottom loaded, 8.23 +/- 0.18% vs 3.03 +/- 0.26%; p = 0.005). Ocular deposition varied by an order of magnitude and was a strong function of mask design (4.77 +/- 0.24% vs 0.35 +/- 0.05%, p = 0.002, tight fitting vs prototype). Particle sizes (7.3 to 9 microm) were larger than previously reported for budesonide. For pediatric breathing patterns, mask design is a key factor defining budesonide delivery to the lungs, face, and eyes. Front-loaded nebulizer mask combinations are more efficient than bottom-loaded systems.

  5. What's in a mask? Information masking with forward and backward visual masks.

    PubMed

    Davis, Chris; Kim, Jeesun

    2011-10-01

    Three experiments tested how the physical format and information content of forward and backward masks affected the extent of visual pattern masking. This involved using different types of forward and backward masks with target discrimination measured by percentage correct in the first experiment (with a fixed target duration) and by an adaptive threshold procedure in the last two. The rationale behind the manipulation of the content of the masks stemmed from masking theories emphasizing attentional and/or conceptual factors rather than visual ones. Experiment 1 used word masks and showed that masking was reduced (a masking reduction effect) when the forward and backward masks were the same word (although in different case) compared to when the masks were different words. Experiment 2 tested the extent to which a reduction in masking might occur due to the physical similarity between the forward and backward masks by comparing the effect of the same content of the masks in the same versus different case. The result showed a significant reduction in masking for same content masks but no significant effect of case. The last experiment examined whether the reduction in masking effect would be observed with nonword masks--that is, having no high-level representation. No reduction in masking was found from same compared to different nonword masks (Experiment 3). These results support the view that the conscious perception of a rapidly displayed target stimulus is in part determined by high-level perceptual/cognitive factors concerned with masking stimulus grouping and attention.

  6. Delivery of helium–oxygen mixture during spontaneous breathing: evaluation of three high-concentration face masks.

    PubMed

    Roche-Campo, Ferran; Vignaux, Laurence; Galia, Fabrice; Lyazidi, Aissam; Vargas, Frédéric; Texereau, Joëlle; Apiou-Sbirlea, Gabriela; Jolliet, Philippe; Brochard, Laurent

    2011-11-01

    To evaluate the efficacy of delivering a mixture of helium and oxygen gas (He–O2) in spontaneous ventilation. Three high oxygen flow reservoir masks were tested: the Heliox21, specifically designed for helium; the Hi-Ox80 mask, with an inspiratory and an expiratory valve; and a standard high-concentration face mask. This prospective randomized crossover study was performed in six healthy volunteers in a laboratory setting. Volunteers breathed a mixture of 78% He/22% O2 through each of the masks under two different breathing conditions (rest and hyperventilation: minute ventilation of 14.9 ± 6.1 and 26.7 ± 8.7 L min(−1), respectively) and four different He–O2 flow rates (7, 10, 12, and 15 L min(−1)). A nasopharyngeal catheter was used to estimate He pharyngeal concentration (Fp [He]) in the airways in order to determine the percentage of contamination with room air (% air cont) at end-expiration. Under all testing conditions, the Hi-Ox80 mask presented a significantly lower % air cont. During resting breathing pattern, a Fp [He] higher than 50% was achieved in 54% of the tests performed with the Hi-Ox80 mask compared to 29% for the Heliox21 mask and only 17% for the standard mask. At hyperventilation, a Fp [He] higher than 50% was achieved in 17% of the tests performed with the Hi-Ox mask compared to 4% for the other two masks. He–O2 administration via the usual high-concentration reservoir masks results in significant dilution by room air. The Hi-Ox80 mask minimized room air contamination and much more frequently achieved a pharyngeal He concentration higher than 50%.

  7. Effect of Ibuprofen on masking endodontic diagnosis.

    PubMed

    Read, Jason K; McClanahan, Scott B; Khan, Asma A; Lunos, Scott; Bowles, Walter R

    2014-08-01

    An accurate diagnosis is of upmost importance before initiating endodontic treatment; yet, there are occasions when the practitioner cannot reproduce the patient's chief complaint because the patient has become asymptomatic. Ibuprofen taken beforehand may "mask" or eliminate the patient's symptoms. In fact, 64%-83% of patients with dental pain take analgesics before seeing a dentist. The purpose of this study was to examine the possible "masking" effect of ibuprofen on endodontic diagnostic tests. Forty-two patients with endodontic pain underwent testing (cold, percussion, palpation, and bite force measurement) and then received either placebo or 800 mg ibuprofen. Both patients and operators were blinded to the medication received. One hour later, diagnostic testing was repeated and compared with pretreatment testing. Ibuprofen affected testing values for vital teeth by masking palpation 40%, percussion 25%, and cold 25% on affected teeth with symptomatic irreversible pulpitis and symptomatic apical periodontitis. There was no observed masking effect in the placebo group on palpation, percussion, or cold values. When nonvital teeth were included, the masking effect of ibuprofen was decreased. However, little masking occurred with the bite force measurement differences. Analgesics taken before the dental appointment can affect endodontic diagnostic testing results. Bite force measurements can assist in identifying the offending tooth in cases in which analgesics "mask" the endodontic diagnosis. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  8. Emergency face-mask removal effectiveness: a comparison of traditional and nontraditional football helmet face-mask attachment systems.

    PubMed

    Swartz, Erik E; Belmore, Keith; Decoster, Laura C; Armstrong, Charles W

    2010-01-01

    Football helmet face-mask attachment design changes might affect the effectiveness of face-mask removal. To compare the efficiency of face-mask removal between newly designed and traditional football helmets. Controlled laboratory study. Applied biomechanics laboratory. Twenty-five certified athletic trainers. The independent variable was face-mask attachment system on 5 levels: (1) Revolution IQ with Quick Release (QR), (2) Revolution IQ with Quick Release hardware altered (QRAlt), (3) traditional (Trad), (4) traditional with hardware altered (TradAlt), and (5) ION 4D (ION). Participants removed face masks using a cordless screwdriver with a back-up cutting tool or only the cutting tool for the ION. Investigators altered face-mask hardware to unexpectedly challenge participants during removal for traditional and Revolution IQ helmets. Participants completed each condition twice in random order and were blinded to hardware alteration. Removal success, removal time, helmet motion, and rating of perceived exertion (RPE). Time and 3-dimensional helmet motion were recorded. If the face mask remained attached at 3 minutes, the trial was categorized as unsuccessful. Participants rated each trial for level of difficulty (RPE). We used repeated-measures analyses of variance (α  =  .05) with follow-up comparisons to test for differences. Removal success was 100% (48 of 48) for QR, Trad, and ION; 97.9% (47 of 48) for TradAlt; and 72.9% (35 of 48) for QRAlt. Differences in time for face-mask removal were detected (F(4,20)  =  48.87, P  =  .001), with times ranging from 33.96 ± 14.14 seconds for QR to 99.22 ± 20.53 seconds for QRAlt. Differences were found in range of motion during face-mask removal (F(4,20)  =  16.25, P  =  .001), with range of motion from 10.10° ± 3.07° for QR to 16.91° ± 5.36° for TradAlt. Differences also were detected in RPE during face-mask removal (F(4,20)  =  43.20, P  =  .001), with participants reporting average perceived difficulty ranging from 1.44 ± 1.19 for QR to 3.68 ± 1.70 for TradAlt. The QR and Trad trials resulted in superior results. When trials required cutting loop straps, results deteriorated.

  9. ELECTRIC PULSE GENERATOR

    DOEpatents

    Buntenbach, R.W.

    1959-06-01

    S>An electro-optical apparatus is described which produces electric pulses in programmed sequences at times and durations controlled with great accuracy. An oscilloscope CRT is supplied with signals to produce a luminous spot moving in a circle. An opaque mask with slots of variable width transmits light from the spot to a photoelectric transducer. For shorter pulse decay times a CRT screen which emits UV can be used with a UVtransmitting filter and a UV- sensitive photoelectric cell. Pulses are varied by changing masks or by using masks with variable slots. This device may be used in multiple arrangements to produce other pulse aT rangements, or it can be used to trigger an electronic pulse generator. (T.R.H.)

  10. Respiratory Source Control Using Surgical Masks With Nanofiber Media

    PubMed Central

    Skaria, Shaji D.; Smaldone, Gerald C.

    2014-01-01

    Background: Potentially infected individuals (‘source’) are sometimes encouraged to use face masks to reduce exposure of their infectious aerosols to others (‘receiver’). To improve compliance with Respiratory Source Control via face mask and therefore reduce receiver exposure, a mask should be comfortable and effective. We tested a novel face mask designed to improve breathability and filtration using nanofiber filtration. Methods: Using radiolabeled test aerosols and a calibrated exposure chamber simulating source to receiver interaction, facepiece function was measured with a life-like ventilated manikin model. Measurements included mask airflow resistance (pressure difference during breathing), filtration, (mask capture of exhaled radiolabeled test aerosols), and exposure (the transfer of ‘infectious’ aerosols from the ‘source’ to a ‘receiver’). Polydisperse aerosols were measured at the source with a mass median aerodynamic diameter of 0.95 µm. Approximately 90% of the particles were <2.0 µm. Tested facepieces included nanofiber prototype surgical masks, conventional surgical masks, and for comparison, an N95-class filtering facepiece respirator (commonly known as an ‘N95 respirator’). Airflow through and around conventional surgical face mask and nanofiber prototype face mask was visualized using Schlieren optical imaging. Results: Airflow resistance [ΔP, cmH2O] across sealed surgical masks (means: 0.1865 and 0.1791 cmH2O) approached that of the N95 (mean: 0.2664 cmH2O). The airflow resistance across the nanofiber face mask whether sealed or not sealed (0.0504 and 0.0311 cmH2O) was significantly reduced in comparison. In addition, ‘infected’ source airflow filtration and receiver exposure levels for nanofiber face masks placed on the source were comparable to that achieved with N95 placed on the source; 98.98% versus 82.68% and 0.0194 versus 0.0557, respectively. Compared to deflection within and around the conventional face masks, Schlieren optical imaging demonstrated enhanced airflow through the nanofiber mask. Conclusions: Substituting nanofiber for conventional filter media significantly reduced face mask airflow resistance directing more airflow through the face mask resulting in enhanced filtration. Respiratory source control efficacy similar to that achieved through the use of an N95 respirator worn by the source and decreased airflow resistance using nanofiber masks may improve compliance and reduce receiver exposure. PMID:24737728

  11. Respiratory source control using surgical masks with nanofiber media.

    PubMed

    Skaria, Shaji D; Smaldone, Gerald C

    2014-07-01

    Potentially infected individuals ('source') are sometimes encouraged to use face masks to reduce exposure of their infectious aerosols to others ('receiver'). To improve compliance with Respiratory Source Control via face mask and therefore reduce receiver exposure, a mask should be comfortable and effective. We tested a novel face mask designed to improve breathability and filtration using nanofiber filtration. Using radiolabeled test aerosols and a calibrated exposure chamber simulating source to receiver interaction, facepiece function was measured with a life-like ventilated manikin model. Measurements included mask airflow resistance (pressure difference during breathing), filtration, (mask capture of exhaled radiolabeled test aerosols), and exposure (the transfer of 'infectious' aerosols from the 'source' to a 'receiver'). Polydisperse aerosols were measured at the source with a mass median aerodynamic diameter of 0.95 µm. Approximately 90% of the particles were <2.0 µm. Tested facepieces included nanofiber prototype surgical masks, conventional surgical masks, and for comparison, an N95-class filtering facepiece respirator (commonly known as an 'N95 respirator'). Airflow through and around conventional surgical face mask and nanofiber prototype face mask was visualized using Schlieren optical imaging. Airflow resistance [ΔP, cmH2O] across sealed surgical masks (means: 0.1865 and 0.1791 cmH2O) approached that of the N95 (mean: 0.2664 cmH2O). The airflow resistance across the nanofiber face mask whether sealed or not sealed (0.0504 and 0.0311 cmH2O) was significantly reduced in comparison. In addition, 'infected' source airflow filtration and receiver exposure levels for nanofiber face masks placed on the source were comparable to that achieved with N95 placed on the source; 98.98% versus 82.68% and 0.0194 versus 0.0557, respectively. Compared to deflection within and around the conventional face masks, Schlieren optical imaging demonstrated enhanced airflow through the nanofiber mask. Substituting nanofiber for conventional filter media significantly reduced face mask airflow resistance directing more airflow through the face mask resulting in enhanced filtration. Respiratory source control efficacy similar to that achieved through the use of an N95 respirator worn by the source and decreased airflow resistance using nanofiber masks may improve compliance and reduce receiver exposure. © The Author 2014. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  12. A cluster randomized clinical trial comparing fit‐tested and non‐fit‐tested N95 respirators to medical masks to prevent respiratory virus infection in health care workers

    PubMed Central

    MacIntyre, Chandini Raina; Wang, Quanyi; Cauchemez, Simon; Seale, Holly; Dwyer, Dominic E.; Yang, Peng; Shi, Weixian; Gao, Zhanhai; Pang, Xinghuo; Zhang, Yi; Wang, Xiaoli; Duan, Wei; Rahman, Bayzidur; Ferguson, Neil

    2011-01-01

    Please cite this paper as: MacIntyre et al. (2011) A cluster randomized clinical trial comparing fit‐tested and non‐fit‐tested N95 respirators to medical masks to prevent respiratory virus infection in health care workers. Influenza and Other Respiratory Viruses DOI: 10.1111/j.1750‐2659.2010.00198.x. Background  We compared the efficacy of medical masks, N95 respirators (fit tested and non fit tested), in health care workers (HCWs). Methods  A cluster randomized clinical trial (RCT) of 1441 HCWs in 15 Beijing hospitals was performed during the 2008/2009 winter. Participants wore masks or respirators during the entire work shift for 4 weeks. Outcomes included clinical respiratory illness (CRI), influenza‐like illness (ILI), laboratory‐confirmed respiratory virus infection and influenza. A convenience no‐mask/respirator group of 481 health workers from nine hospitals was compared. Findings  The rates of CRI (3·9% versus 6·7%), ILI (0·3% versus 0·6%), laboratory‐confirmed respiratory virus (1·4% versus 2·6%) and influenza (0·3% versus 1%) infection were consistently lower for the N95 group compared to medical masks. By intention‐to‐treat analysis, when P values were adjusted for clustering, non‐fit‐tested N95 respirators were significantly more protective than medical masks against CRI, but no other outcomes were significant. The rates of all outcomes were higher in the convenience no‐mask group compared to the intervention arms. There was no significant difference in outcomes between the N95 arms with and without fit testing. Rates of fit test failure were low. In a post hoc analysis adjusted for potential confounders, N95 masks and hospital level were significant, but medical masks, vaccination, handwashing and high‐risk procedures were not. Interpretation  Rates of infection in the medical mask group were double that in the N95 group. A benefit of respirators is suggested but would need to be confirmed by a larger trial, as this study may have been underpowered. The finding on fit testing is specific to the type of respirator used in the study and cannot be generalized to other respirators. Trial registration  Australian New Zealand Clinical Trials Registry (ANZCTR), ACTRN: ACTRN12609000257268 (http://www.anzctr.org.au). PMID:21477136

  13. Study of shape evaluation for mask and silicon using large field of view

    NASA Astrophysics Data System (ADS)

    Matsuoka, Ryoichi; Mito, Hiroaki; Shinoda, Shinichi; Toyoda, Yasutaka

    2010-09-01

    We have developed a highly integrated method of mask and silicon metrology. The aim of this integration is evaluating the performance of the silicon corresponding to Hotspot on a mask. It can use the mask shape of a large field, besides. The method adopts a metrology management system based on DBM (Design Based Metrology). This is the high accurate contouring created by an edge detection algorithm used in mask CD-SEM and silicon CD-SEM. Currently, as semiconductor manufacture moves towards even smaller feature size, this necessitates more aggressive optical proximity correction (OPC) to drive the super-resolution technology (RET). In other words, there is a trade-off between highly precise RET and mask manufacture, and this has a big impact on the semiconductor market that centers on the mask business. As an optimal solution to these issues, we provide a DFM solution that extracts 2-dimensional data for a more realistic and error-free simulation by reproducing accurately the contour of the actual mask, in addition to the simulation results from the mask data. On the other hand, there is roughness in the silicon form made from a mass-production line. Moreover, there is variation in the silicon form. For this reason, quantification of silicon form is important, in order to estimate the performance of a pattern. In order to quantify, the same form is equalized in two dimensions. And the method of evaluating based on the form is popular. In this study, we conducted experiments for averaging method of the pattern (Measurement Based Contouring) as two-dimensional mask and silicon evaluation technique. That is, observation of the identical position of a mask and a silicon was considered. The result proved its detection accuracy and reliability of variability on two-dimensional pattern (mask and silicon) and is adaptable to following fields of mask quality management. •Discrimination of nuisance defects for fine pattern. •Determination of two-dimensional variability of pattern. •Verification of the performance of the pattern of various kinds of Hotspots. In this report, we introduce the experimental results and the application. We expect that the mask measurement and the shape control on mask production will make a huge contribution to mask yield-enhancement and that the DFM solution for mask quality control process will become much more important technology than ever. It is very important to observe the form of the same location of Design, Mask, and Silicon in such a viewpoint. And we report it about algorithm of the image composition in Large Field.

  14. Efficacy of a heat exchanger mask in cold exercise-induced asthma.

    PubMed

    Beuther, David A; Martin, Richard J

    2006-05-01

    To determine the efficacy of a novel mask device in limiting cold air exercise-induced decline in lung function in subjects with a history of exercise-induced asthma (EIA). In spite of appropriate medical therapy, many asthma patients are limited in cold weather activities. In study 1, 13 asthmatic subjects performed two randomized, single-blind treadmill exercise tests while breathing cold air (- 25 to - 15 degrees C) through a placebo or active heat exchanger mask. In study 2, five subjects with EIA performed three treadmill exercise tests while breathing cold air: one test using the heat exchanger mask, one test without the mask but with albuterol pretreatment, and one test with neither the mask nor albuterol pretreatment (unprotected exercise). For all studies, spirometry was performed before and at 5, 15, and 30 min after exercise challenge. For both studies, a total of 15 subjects with a history of asthma symptoms during cold air exercise were recruited. In study 1, the mean decrease (+/- SE) in FEV1 was 19 +/- 4.9% with placebo, and 4.3 +/- 1.6% with the active device (p = 0.0002). The mean decrease in maximum mid-expiratory flow (FEF(25-75)) was 31 +/- 5.7% with placebo and 4.7 +/- 1.7% with the active device (p = 0.0002). In study 2, the mean decrease in FEV1 was 6.3 +/- 3.9%, 11 +/- 3.7%, and 28 +/- 10% for the heat exchanger mask, albuterol pretreatment, and unprotected exercises, respectively (p = 0.4375 for mask vs albuterol, p = 0.0625 for mask vs unprotected exercise). The mean decrease in FEF(25-75) was 10 +/- 4.8%, 23 +/- 6.0%, and 36 +/- 11%, respectively (p = 0.0625 for mask vs albuterol, p = 0.0625 for mask vs unprotected exercise). This heat exchanger mask blocks cold exercise-induced decline in lung function at least as effectively as albuterol pretreatment.

  15. If the MODIS Aerosol Product is so Infested with Cloud Contamination, Why Does Everybody Use the Product?

    NASA Technical Reports Server (NTRS)

    Remeer, Lorraine A.

    2011-01-01

    The MODIS aerosol cloud mask is based on a spatial variability test, using the assumption that aerosols are more homogeneous than clouds. On top of this first line of defense are a series of additional tests based on threshold values and ratios of various MODIS channels. The goal is to eliminate clouds and keep the aerosol. How well have we succeeded? There have been several studies showing cloud contamination in the MODIS aerosol product and several alternative cloud masks proposed. There are even "competing" MODIS aerosol products that offer an alternative "cloud free" world. Are these alternative products an improvement to the old standard product? We find there is a trade-off between retrieval availability and cloud contamination, and for many applications it is better to have a little bit of cloud in the product than to not have enough product. I will review the decisions that led us to the present MODIS cloud mask, and show how it is simultaneously too liberal and too conservative, some ideas on how to make it better and why in the end it doesn't matter. I hope to inspire a spirited discussion and will be very willing to take your complaints and suggestions.

  16. The influence of informational masking on speech perception and pupil response in adults with hearing impairment.

    PubMed

    Koelewijn, Thomas; Zekveld, Adriana A; Festen, Joost M; Kramer, Sophia E

    2014-03-01

    A recent pupillometry study on adults with normal hearing indicates that the pupil response during speech perception (cognitive processing load) is strongly affected by the type of speech masker. The current study extends these results by recording the pupil response in 32 participants with hearing impairment (mean age 59 yr) while they were listening to sentences masked by fluctuating noise or a single-talker. Efforts were made to improve audibility of all sounds by means of spectral shaping. Additionally, participants performed tests measuring verbal working memory capacity, inhibition of interfering information in working memory, and linguistic closure. The results showed worse speech reception thresholds for speech masked by single-talker speech compared to fluctuating noise. In line with previous results for participants with normal hearing, the pupil response was larger when listening to speech masked by a single-talker compared to fluctuating noise. Regression analysis revealed that larger working memory capacity and better inhibition of interfering information related to better speech reception thresholds, but these variables did not account for inter-individual differences in the pupil response. In conclusion, people with hearing impairment show more cognitive load during speech processing when there is interfering speech compared to fluctuating noise.

  17. Simulant Agent Resistance Test Manikin (SMARTMAN) Testing of Protective Mask Systems

    DTIC Science & Technology

    2013-09-16

    after approval of the test plan and conduct of the test readiness review (TRR) or equivalent, and/or other installation pretest reviews. 3.1.1...to various types of pre- test conditioning. The number of masks chosen to represent each type of pretest conditioning will be divided (equally...This does not negate the pretest conditioning. TOP 08-2-109 16 September 2013 8 a. Masks undergoing BFC conditioning will be conditioned before

  18. Light masking of circadian rhythms of heat production, heat loss, and body temperature in squirrel monkeys

    NASA Technical Reports Server (NTRS)

    Robinson, E. L.; Fuller, C. A.

    1999-01-01

    Whole body heat production (HP) and heat loss (HL) were examined to determine their relative contributions to light masking of the circadian rhythm in body temperature (Tb). Squirrel monkey metabolism (n = 6) was monitored by both indirect and direct calorimetry, with telemetered measurement of body temperature and activity. Feeding was also measured. Responses to an entraining light-dark (LD) cycle (LD 12:12) and a masking LD cycle (LD 2:2) were compared. HP and HL contributed to both the daily rhythm and the masking changes in Tb. All variables showed phase-dependent masking responses. Masking transients at L or D transitions were generally greater during subjective day; however, L masking resulted in sustained elevation of Tb, HP, and HL during subjective night. Parallel, apparently compensatory, changes of HL and HP suggest action by both the circadian timing system and light masking on Tb set point. Furthermore, transient HL increases during subjective night suggest that gain change may supplement set point regulation of Tb.

  19. A survey of Alberta physicians' use of and attitudes toward face masks and face shields in the operating room setting.

    PubMed

    Davis, Philip J; Spady, Donald; Forgie, Sarah E D

    2007-09-01

    There is little evidence that surgical mask use by physicians in the operating room (OR) reduces surgical site infections (SSIs), but masks do protect the wearer from potentially infectious splashes. Face shields offer even more protection because they cover the eyes, but they may be perceived as offering less protection to the patient than do masks. The objectives of this study were to ascertain if there were predictors to determine which OR physicians are continuing to use masks and what their reasons are for doing so, and which OR physicians would accept face shields and their reasons for doing so. We surveyed the province of Alberta's surgeons, general practice (GP) surgeons, anesthesiologists, and GP anesthetists to determine how many physicians in the OR wear surgical masks, their reasons for wearing surgical masks (ethical, legal, protection of the patient, protection of the wearer), and if they believe that face shields offer more protection to the patient or to the wearer. We also sought to examine which demographic factors affected their responses. The data were examined with chi(2) analysis to assess the relationships of age and practitioner type, and for various outcome variables. A significance level of P < .05 was accepted as statistically significant. The sex of the physician did not affect his/her responses. Older physicians believe that the OR team has an ethical and legal responsibility to wear surgical masks; masks are worn to prevent the spread of disease, not because it is tradition to do so; masks protect the wearer more than do face shields; and wearing face shields alone will subject the patient to higher rates of SSIs. Surgeons are more likely than are anesthesiologists to wear surgical masks in the OR and wear a surgical mask and a face shield if the patient has risk factors for a blood borne infection. According to our survey, age and profession were the most important variables that affected the potential use of surgical masks and face shields. Younger OR physicians likely would be amenable to using face shields in addition to masks in the OR to protect themselves from exposure to blood or bodily fluids.

  20. Wave Energy Prize MASK wave calibration data for the 1:20 scale testing at MASK

    DOE Data Explorer

    Driscoll, Rick

    2017-05-08

    Time series data, sensor layout, and wave calibration summaries for the wave height measurements for the 10 calibration sea states for the 1:20 scale testing of the Wave Energy Prize (WEP) at the US Navy's Maneuvering and Seakeeping (MASK) Basin at the Naval Surface Warfare Center in Carderock, Maryland. Measurements were made in the test area and upstream of the test area.

  1. Image discrimination models predict detection in fixed but not random noise

    NASA Technical Reports Server (NTRS)

    Ahumada, A. J. Jr; Beard, B. L.; Watson, A. B. (Principal Investigator)

    1997-01-01

    By means of a two-interval forced-choice procedure, contrast detection thresholds for an aircraft positioned on a simulated airport runway scene were measured with fixed and random white-noise masks. The term fixed noise refers to a constant, or unchanging, noise pattern for each stimulus presentation. The random noise was either the same or different in the two intervals. Contrary to simple image discrimination model predictions, the same random noise condition produced greater masking than the fixed noise. This suggests that observers seem unable to hold a new noisy image for comparison. Also, performance appeared limited by internal process variability rather than by external noise variability, since similar masking was obtained for both random noise types.

  2. X-ray mask fabrication advancements at the Microlithographic Mask Development Center

    NASA Astrophysics Data System (ADS)

    Kimmel, Kurt R.; Hughes, Patrick J.

    1996-05-01

    The Microlithographic Mask Development Center (MMD) was established as the X-ray mask manufacturing facility at the IBM Microelectronics Division semiconductor fabricator in Essex Junction, Vermont. This center, in operation for over two years, produces high yielding, defect-free X-ray masks for competitive logic and memory products at 250nm groundrules and below. The MMD is a complete mask facility that manufactures silicon membrane mask blanks in the NIST format and finished masks with electroplated gold X-ray absorber. Mask patterning, with dimensions as small as 180 nm, is accomplished using IBM-built variable shaped spot e-beam systems. Masks are routinely inspected and repaired using state-of-the-art equipment: two KLA SEM Specs for defect inspection, a Leica LMS 2000 for image placement characterization, an Amray 2040c for image dimension characterization and a Micrion 8000 XMR for defect repair. This facility maintains a baseline mask process with daily production of 250nm, 32Mb SRAM line monitor masks for the continuous improvement of mask quality and processes. Development masks are produced for several semiconductor manufacturers including IBM, Motorola, Loral, and Sanders. Masks for 64Mb and 256Mb DRAM (IBM) and advanced logic/SRAM (IBM and Motorola) designs have also been delivered. This paper describes the MMD facility and its technical capabilities. Key manufacturing metrics such as mask turnaround time, parametric yield learning and defect reduction activities are highlighted. The challenges associated with improved mask quality, sub-180nm mask fabrication, and the transition to refractory metal absorber are discussed.

  3. A further test of the linearity of temporal summation in forward masking.

    PubMed

    Plack, Christopher J; Carcagno, Samuele; Oxenham, Andrew J

    2007-10-01

    An experiment tested the hypothesis that the masking effects of two nonoverlapping forward maskers are summed linearly over time. First, the levels of individual noise maskers required to mask a brief 4-kHz signal presented at 10-, 20-, 30-, or 40-dB sensation level (SL) were found. The hypothesis predicts that a combination of the first masker presented at the level required to mask the 10-dB SL signal and the second masker presented at the level required to mask the 20-dB SL signal, should produce the same amount of masking as the converse situation (i.e., the first masker presented at the level required to mask the 20-dB SL signal and the second masker presented at the level required to mask the 10-dB SL signal), and similarly for the 30- and 40-dB SL signals. The results were consistent with the predictions.

  4. Phase-shifting point diffraction interferometer mask designs

    DOEpatents

    Goldberg, Kenneth Alan

    2001-01-01

    In a phase-shifting point diffraction interferometer, different image-plane mask designs can improve the operation of the interferometer. By keeping the test beam window of the mask small compared to the separation distance between the beams, the problem of energy from the reference beam leaking through the test beam window is reduced. By rotating the grating and mask 45.degree., only a single one-dimensional translation stage is required for phase-shifting. By keeping two reference pinholes in the same orientation about the test beam window, only a single grating orientation, and thus a single one-dimensional translation stage, is required. The use of a two-dimensional grating allows for a multiplicity of pinholes to be used about the pattern of diffracted orders of the grating at the mask. Orientation marks on the mask can be used to orient the device and indicate the position of the reference pinholes.

  5. Barriers to mask wearing for influenza-like illnesses among urban Hispanic households.

    PubMed

    Ferng, Yu-hui; Wong-McLoughlin, Jennifer; Barrett, Angela; Currie, Leanne; Larson, Elaine

    2011-01-01

    To identify barriers to mask wearing and to examine the factors associated with the willingness to wear masks among households. We used data sources from a study assessing the impact of 3 nonpharmaceutical interventions on the rates of influenza: exit interviews; home visits with a subset of the mask group; and a focus group. Risk perception score, univariate analysis, and logistic regression were conducted to identify the characteristics and predictors of mask use. Thematic barriers to mask wearing were identified from qualitative data obtained at home visits and focus group. Respondents from the mask group, when compared with the nonmask group, demonstrated higher risk perception scores concerning influenza (maximum score: 60, means: 37.6 and 30.2, p<.001) and increased perception of effectiveness of mask wearing (maximum score: 10, means: 7.8 and 7.3, p=.043). There was no significant association between demographic, attitudinal, or knowledge variables and adherence to wearing masks. Thematic barriers were identified such as social acceptability of mask use, comfort and fit, and perception of the risk/need for masks. Face masks may not be an effective intervention for seasonal or pandemic influenza unless the risk perception of influenza is high. Dissemination of culturally appropriate mask use information by health authorities and providers must be emphasized when educating the public. © 2010 Wiley Periodicals, Inc.

  6. Reflective Occultation Mask for Evaluation of Occulter Designs for Planet Finding

    NASA Technical Reports Server (NTRS)

    Hagopian, John; Lyon, Richard; Shiri, Shahram; Roman, Patrick

    2011-01-01

    Advanced formation flying occulter designs utilize a large occulter mask flying in formation with an imaging telescope to block and null starlight to allow imaging of faint planets in exosolar systems. A paper describes the utilization of subscale reflective occultation masks to evaluate formation flying occulter designs. The use of a reflective mask allows mounting of the occulter by conventional means and simplifies the test configuration. The innovation alters the test set-up to allow mounting of the mask using standard techniques to eliminate the problems associated with a standard configuration. The modified configuration uses a reflective set-up whereby the star simulator reflects off of a reflective occulting mask and into an evaluation telescope. Since the mask is sized to capture all rays required for the imaging test, it can be mounted directly to a supporting fixture without interfering with the beam. Functionally, the reflective occultation mask reflects light from the star simulator instead of transmitting it, with a highly absorptive carbon nanotube layer simulating the occulter blocking mask. A subscale telescope images the star source and companion dim source that represents a planet. The primary advantage of this is that the occulter can be mounted conventionally instead of using diffractive wires or magnetic levitation.

  7. Foul tip impact attenuation of baseball catcher masks using head impact metrics

    PubMed Central

    White, Terrance R.; Cutcliffe, Hattie C.; Shridharani, Jay K.; Wood, Garrett W.; Bass, Cameron R.

    2018-01-01

    Currently, no scientific consensus exists on the relative safety of catcher mask styles and materials. Due to differences in mass and material properties, the style and material of a catcher mask influences the impact metrics observed during simulated foul ball impacts. The catcher surrogate was a Hybrid III head and neck equipped with a six degree of freedom sensor package to obtain linear accelerations and angular rates. Four mask styles were impacted using an air cannon for six 30 m/s and six 35 m/s impacts to the nasion. To quantify impact severity, the metrics peak linear acceleration, peak angular acceleration, Head Injury Criterion, Head Impact Power, and Gadd Severity Index were used. An Analysis of Covariance and a Tukey’s HSD Test were conducted to compare the least squares mean between masks for each head injury metric. For each injury metric a P-Value less than 0.05 was found indicating a significant difference in mask performance. Tukey’s HSD test found for each metric, the traditional style titanium mask fell in the lowest performance category while the hockey style mask was in the highest performance category. Limitations of this study prevented a direct correlation from mask testing performance to mild traumatic brain injury. PMID:29856814

  8. Machine learning for inverse lithography: using stochastic gradient descent for robust photomask synthesis

    NASA Astrophysics Data System (ADS)

    Jia, Ningning; Y Lam, Edmund

    2010-04-01

    Inverse lithography technology (ILT) synthesizes photomasks by solving an inverse imaging problem through optimization of an appropriate functional. Much effort on ILT is dedicated to deriving superior masks at a nominal process condition. However, the lower k1 factor causes the mask to be more sensitive to process variations. Robustness to major process variations, such as focus and dose variations, is desired. In this paper, we consider the focus variation as a stochastic variable, and treat the mask design as a machine learning problem. The stochastic gradient descent approach, which is a useful tool in machine learning, is adopted to train the mask design. Compared with previous work, simulation shows that the proposed algorithm is effective in producing robust masks.

  9. Adaptation, saturation, and physiological masking in single auditory-nerve fibers.

    PubMed

    Smith, R L

    1979-01-01

    Results are reviewed concerning some effects, at a units's characteristic frequency, of a short-term conditioning stimulus on the responses to perstimulatory and poststimulatory test tones. A phenomenological equation is developed from the poststimulatory results and shown to be consistent with the perstimulatory results. According to the results and equation, the response to a test tone equals the unconditioned or unadapted response minus the decrement produced by adaptation to the conditioning tone. Furthermore, the decrement is proportional to the driven response to the conditioning tone and does not depend on sound intensity per se. The equation has a simple interpretation in terms of two processes in cascade--a static saturating nonlinearity followed by additive adaptation. Results are presented to show that this functional model is sufficient to account for the "physiological masking" produced by wide-band backgrounds. According to this interpretation, a sufficiently intense background produces saturation. Consequently, a superimposed test tone cause no change in response. In addition, when the onset of the background precedes the onset of the test tone, the total firing rate is reduced by adaptation. Evidence is reviewed concerning the possible correspondence between the variables in the model and intracellular events in the auditory periphery.

  10. Penetration of diesel exhaust particles through commercially available dust half masks.

    PubMed

    Penconek, Agata; Drążyk, Paulina; Moskal, Arkadiusz

    2013-04-01

    Half masks are certified by the competent, national institutions--National Institute for Occupational Safety and Health (NIOSH) in the USA and the respective European national institutions applying common European regulations. However, certification testing is conducted with particles of NaCl, paraffin oil, or dioctyl phthalate (DOP) and at the constant flow rate, whereas particles commonly found in workplaces may differ in size, shape, and morphology from these particles. Therefore, the aim of this study was to investigate filtration efficiency of commercially available filtering facepiece half masks under the condition of exposure to diesel fumes. In this study, we focused on the particulate phase [diesel exhaust particles (DEP)] of three (petroleum diesel, ecodiesel, and biodiesel) diesel fuel combustion types. Two types of European standard-certified half masks, FFP2 and FFP - Filtering Facepiece, and three types of popular diesel fuels were tested. The study showed that the filtration efficiencies for each examined half mask and for each of diesel exhaust fumes were lower than the minimum filtration efficiency required for the standard test aerosols by the European standards. For FFP2 and FFP3 particulate half masks, standard minimum filtration efficiency is 94 and 99%, respectively, whereas 84-89% of mass of DEP from various fuels were filtered by the tested FFP2 and only 75-86% by the FFP3. The study indicated that DEP is more penetrating for these filters than the standard salt or paraffin oil test aerosols. The study also showed that the most penetrating DEP are probably in the 30- to 300-nm size range, regardless of the fuel type and the half-mask model. Finally, the pressure drops across both half masks during the 80-min tests remained below an acceptable maximum of breathing resistance-regardless of the fuel types. The respiratory system, during 40-min test exposures, may be exposed to 12-16mg of DEP if a FFP2 or FFP3 particulate half mask is used. To conclude, commercially available half masks may not ensure a sufficient level of protection of the respiratory tract against diesel exhaust fumes.

  11. Masking Period Patterns and Forward Masking for Speech-Shaped Noise: Age-Related Effects.

    PubMed

    Grose, John H; Menezes, Denise C; Porter, Heather L; Griz, Silvana

    2016-01-01

    The purpose of this study was to assess age-related changes in temporal resolution in listeners with relatively normal audiograms. The hypothesis was that increased susceptibility to nonsimultaneous masking contributes to the hearing difficulties experienced by older listeners in complex fluctuating backgrounds. Participants included younger (n = 11), middle-age (n = 12), and older (n = 11) listeners with relatively normal audiograms. The first phase of the study measured masking period patterns for speech-shaped noise maskers and signals. From these data, temporal window shapes were derived. The second phase measured forward-masking functions and assessed how well the temporal window fits accounted for these data. The masking period patterns demonstrated increased susceptibility to backward masking in the older listeners, compatible with a more symmetric temporal window in this group. The forward-masking functions exhibited an age-related decline in recovery to baseline thresholds, and there was also an increase in the variability of the temporal window fits to these data. This study demonstrated an age-related increase in susceptibility to nonsimultaneous masking, supporting the hypothesis that exacerbated nonsimultaneous masking contributes to age-related difficulties understanding speech in fluctuating noise. Further support for this hypothesis comes from limited speech-in-noise data, suggesting an association between susceptibility to forward masking and speech understanding in modulated noise.

  12. Emergency Face-Mask Removal Effectiveness: A Comparison of Traditional and Nontraditional Football Helmet Face-Mask Attachment Systems

    PubMed Central

    Swartz, Erik E.; Belmore, Keith; Decoster, Laura C.; Armstrong, Charles W.

    2010-01-01

    Abstract Context: Football helmet face-mask attachment design changes might affect the effectiveness of face-mask removal. Objective: To compare the efficiency of face-mask removal between newly designed and traditional football helmets. Design: Controlled laboratory study. Setting: Applied biomechanics laboratory. Participants: Twenty-five certified athletic trainers. Intervention(s): The independent variable was face-mask attachment system on 5 levels: (1) Revolution IQ with Quick Release (QR), (2) Revolution IQ with Quick Release hardware altered (QRAlt), (3) traditional (Trad), (4) traditional with hardware altered (TradAlt), and (5) ION 4D (ION). Participants removed face masks using a cordless screwdriver with a back-up cutting tool or only the cutting tool for the ION. Investigators altered face-mask hardware to unexpectedly challenge participants during removal for traditional and Revolution IQ helmets. Participants completed each condition twice in random order and were blinded to hardware alteration. Main Outcome Measure(s): Removal success, removal time, helmet motion, and rating of perceived exertion (RPE). Time and 3-dimensional helmet motion were recorded. If the face mask remained attached at 3 minutes, the trial was categorized as unsuccessful. Participants rated each trial for level of difficulty (RPE). We used repeated-measures analyses of variance (α  =  .05) with follow-up comparisons to test for differences. Results: Removal success was 100% (48 of 48) for QR, Trad, and ION; 97.9% (47 of 48) for TradAlt; and 72.9% (35 of 48) for QRAlt. Differences in time for face-mask removal were detected (F4,20  =  48.87, P  =  .001), with times ranging from 33.96 ± 14.14 seconds for QR to 99.22 ± 20.53 seconds for QRAlt. Differences were found in range of motion during face-mask removal (F4,20  =  16.25, P  =  .001), with range of motion from 10.10° ± 3.07° for QR to 16.91° ± 5.36° for TradAlt. Differences also were detected in RPE during face-mask removal (F4,20  =  43.20, P  =  .001), with participants reporting average perceived difficulty ranging from 1.44 ± 1.19 for QR to 3.68 ± 1.70 for TradAlt. Conclusions: The QR and Trad trials resulted in superior results. When trials required cutting loop straps, results deteriorated. PMID:21062179

  13. Two Words, One Meaning: Evidence of Automatic Co-Activation of Translation Equivalents

    PubMed Central

    Dimitropoulou, Maria; Duñabeitia, Jon Andoni; Carreiras, Manuel

    2011-01-01

    Research on the processing of translations offers important insights on how bilinguals negotiate the representation of words from two languages in one mind and one brain. Evidence so far has shown that translation equivalents effectively activate each other as well as their shared concept even when translations lack of any formal overlap (i.e., non-cognates) and even when one of them is presented subliminally, namely under masked priming conditions. In the lexical decision studies testing masked translation priming effects with unbalanced bilinguals a remarkably stable pattern emerges: larger effects in the dominant (L1) to the non-dominant (L2) translation direction, than vice versa. Interestingly, this asymmetry vanishes when simultaneous and balanced bilinguals are tested, suggesting that the linguistic profile of the bilinguals could be determining the pattern of cross-language lexico-semantic activation across the L2 learning trajectory. The present study aims to detect whether L2 proficiency is the critical variable rendering the otherwise asymmetric cross-language activation of translations obtained in the lexical decision task into symmetric. Non-cognate masked translation priming effects were examined with three groups of Greek (L1)–English (L2) unbalanced bilinguals, differing exclusively at their level of L2 proficiency. Although increased L2 proficiency led to improved overall L2 performance, masked translation priming effects were virtually identical across the three groups, yielding in all cases significant but asymmetric effects (i.e., larger effects in the L1 → L2 than in the L2 → L1 translation direction). These findings show that proficiency does not modulate masked translation priming effects at intermediate levels, and that a native-like level of L2 proficiency is needed for symmetric effects to emerge. They furthermore, pose important constraints on the operation of the mechanisms underlying the development of cross-language lexico-semantic links. PMID:21886634

  14. Parametric and non-parametric masking of randomness in sequence alignments can be improved and leads to better resolved trees.

    PubMed

    Kück, Patrick; Meusemann, Karen; Dambach, Johannes; Thormann, Birthe; von Reumont, Björn M; Wägele, Johann W; Misof, Bernhard

    2010-03-31

    Methods of alignment masking, which refers to the technique of excluding alignment blocks prior to tree reconstructions, have been successful in improving the signal-to-noise ratio in sequence alignments. However, the lack of formally well defined methods to identify randomness in sequence alignments has prevented a routine application of alignment masking. In this study, we compared the effects on tree reconstructions of the most commonly used profiling method (GBLOCKS) which uses a predefined set of rules in combination with alignment masking, with a new profiling approach (ALISCORE) based on Monte Carlo resampling within a sliding window, using different data sets and alignment methods. While the GBLOCKS approach excludes variable sections above a certain threshold which choice is left arbitrary, the ALISCORE algorithm is free of a priori rating of parameter space and therefore more objective. ALISCORE was successfully extended to amino acids using a proportional model and empirical substitution matrices to score randomness in multiple sequence alignments. A complex bootstrap resampling leads to an even distribution of scores of randomly similar sequences to assess randomness of the observed sequence similarity. Testing performance on real data, both masking methods, GBLOCKS and ALISCORE, helped to improve tree resolution. The sliding window approach was less sensitive to different alignments of identical data sets and performed equally well on all data sets. Concurrently, ALISCORE is capable of dealing with different substitution patterns and heterogeneous base composition. ALISCORE and the most relaxed GBLOCKS gap parameter setting performed best on all data sets. Correspondingly, Neighbor-Net analyses showed the most decrease in conflict. Alignment masking improves signal-to-noise ratio in multiple sequence alignments prior to phylogenetic reconstruction. Given the robust performance of alignment profiling, alignment masking should routinely be used to improve tree reconstructions. Parametric methods of alignment profiling can be easily extended to more complex likelihood based models of sequence evolution which opens the possibility of further improvements.

  15. Challenges and requirements of mask data processing for multi-beam mask writer

    NASA Astrophysics Data System (ADS)

    Choi, Jin; Lee, Dong Hyun; Park, Sinjeung; Lee, SookHyun; Tamamushi, Shuichi; Shin, In Kyun; Jeon, Chan Uk

    2015-07-01

    To overcome the resolution and throughput of current mask writer for advanced lithography technologies, the platform of e-beam writer have been evolved by the developments of hardware and software in writer. Especially, aggressive optical proximity correction (OPC) for unprecedented extension of optical lithography and the needs of low sensitivity resist for high resolution result in the limit of variable shaped beam writer which is widely used for mass production. The multi-beam mask writer is attractive candidate for photomask writing of sub-10nm device because of its high speed and the large degree of freedom which enable high dose and dose modulation for each pixel. However, the higher dose and almost unlimited appetite for dose modulation challenge the mask data processing (MDP) in aspects of extreme data volume and correction method. Here, we discuss the requirements of mask data processing for multi-beam mask writer and presents new challenges of the data format, data flow, and correction method for user and supplier MDP tool.

  16. Face mask ventilation--the dos and don'ts.

    PubMed

    Wood, Fiona E; Morley, Colin J

    2013-12-01

    Face mask ventilation provides respiratory support to newly born or sick infants. It is a challenging technique and difficult to ensure that an appropriate tidal volume is delivered because large and variable leaks occur between the mask and face; airway obstruction may also occur. Technique is more important than the mask shape although the size must appropriately fit the face. The essence of the technique is to roll the mask on to the face from the chin while avoiding the eyes, with a finger and thumb apply a strong even downward pressure to the top of the mask, away from the stem and sloped sides or skirt of the mask, place the other fingers under the jaw and apply a similar upward pressure. Preterm infants require continuous end-expiratory pressure to facilitate lung aeration and maintain lung volume. This is best done with a T-piece device, not a self-inflating or flow-inflating bag. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. A Novel Strategy for Bitter Taste Masking of Gankeshuangqing Dispersible Tablets Based on Particle Coating Technology.

    PubMed

    Han, Xue; Zhang, Ding-Kun; Zhang, Fang; Lin, Jun-Zhi; Jiang, Hong; Lan, Yang; Xiong, Xi; Han, Li; Yang, Ming; Fu, Chao-Mei

    2017-01-01

    Currently, acute upper respiratory tract infections (AURTIs) are increasingly becoming a significant health burden. Gankeshuangqing dispersible tablets (GKSQDT) which have a good effect on treating AURTIs. GKSQDT is composed of baicalin and andrographolide. However, its severe bitterness limits application of patients. Due to the addition of plentiful accessories, common masking methods are unsuitable for GKSQDT. It is thus necessary to develop a new masking method. The Previous study showed that baicalin was less bitter than andrographolide. Thus, particle coating technology was adapted to prepare composite particles that baicalin coated on the surface of andrographolide to decrease bitterness. Initially, particle size of baicalin and coating time of composite was investigated to prepare composite. Then, scanning electron microscopy, wettability, and infrared (IR) spectrogram were used to characterize the microstructure of composite. Furthermore, electronic tongue test, animal preference experiment, and human sensory test were applied to evaluate the masking effect. To produce composite, baicalin should be ground in vibromill for 6 min. Then, andrographolide fine powder was added to grind together for 6 min. Contact angle of composite was smaller than mixture, and more similar to baicalin. Other physical characterization including microstructure, wettability, and IR also suggested that andrographolide was successfully coated by baicalin superfine. Furthermore, taste-masking test indicated taste-masked tablets was less bitter than original tablets. The study indicated that particle coating technology can be used for taste masking of GKSQDT without adding other substance. Moreover, it provides a new strategy of taste masking for national medicine. A new strategy to mask bitterness without adding any other substance based on coating technology was providedThe masking effect was confirmed by electronic tongue test, animal preference experiment and human sensory test. Abbreviations used: AURTIs: Acute Upper Respiratory Tract Infections; GSQDT: Gankeshuangqing Dispersible Tablets; IR: Infrared Spectrogram; LHPC: Low-substituted Hydroxypropyl Cellulose; CAs: Contact Angles; FTIR: Fourier Transform Infrared Spectra.

  18. Is masked priming modulated by memory load? A test of the automaticity of masked identity priming in lexical decision.

    PubMed

    Perea, Manuel; Marcet, Ana; Lozano, Mario; Gomez, Pablo

    2018-05-29

    One of the key assumptions of the masked priming lexical decision task (LDT) is that primes are processed without requiring attentional resources. Here, we tested this assumption by presenting a dual-task manipulation to increase memory load and measure the change in masked identity priming on the targets in the LDT. If masked priming does not require attentional resources, increased memory load should have no influence on the magnitude of the observed identity priming effects. We conducted two LDT experiments, using a within-subjects design, to investigate the effect of memory load (via a concurrent matching task Experiment 1 and a concurrent search task in Experiment 2) on masked identity priming. Results showed that the magnitude of masked identity priming on word targets was remarkably similar under high and low memory load. Thus, these experiments provide empirical evidence for the automaticity assumption of masked identity priming in the LDT.

  19. Auditory processing efficiency deficits in children with developmental language impairments

    NASA Astrophysics Data System (ADS)

    Hartley, Douglas E. H.; Moore, David R.

    2002-12-01

    The ``temporal processing hypothesis'' suggests that individuals with specific language impairments (SLIs) and dyslexia have severe deficits in processing rapidly presented or brief sensory information, both within the auditory and visual domains. This hypothesis has been supported through evidence that language-impaired individuals have excess auditory backward masking. This paper presents an analysis of masking results from several studies in terms of a model of temporal resolution. Results from this modeling suggest that the masking results can be better explained by an ``auditory efficiency'' hypothesis. If impaired or immature listeners have a normal temporal window, but require a higher signal-to-noise level (poor processing efficiency), this hypothesis predicts the observed small deficits in the simultaneous masking task, and the much larger deficits in backward and forward masking tasks amongst those listeners. The difference in performance on these masking tasks is predictable from the compressive nonlinearity of the basilar membrane. The model also correctly predicts that backward masking (i) is more prone to training effects, (ii) has greater inter- and intrasubject variability, and (iii) increases less with masker level than do other masking tasks. These findings provide a new perspective on the mechanisms underlying communication disorders and auditory masking.

  20. Testing for entanglement with periodic coarse graining

    NASA Astrophysics Data System (ADS)

    Tasca, D. S.; Rudnicki, Łukasz; Aspden, R. S.; Padgett, M. J.; Souto Ribeiro, P. H.; Walborn, S. P.

    2018-04-01

    Continuous-variable systems find valuable applications in quantum information processing. To deal with an infinite-dimensional Hilbert space, one in general has to handle large numbers of discretized measurements in tasks such as entanglement detection. Here we employ the continuous transverse spatial variables of photon pairs to experimentally demonstrate entanglement criteria based on a periodic structure of coarse-grained measurements. The periodization of the measurements allows an efficient evaluation of entanglement using spatial masks acting as mode analyzers over the entire transverse field distribution of the photons and without the need to reconstruct the probability densities of the conjugate continuous variables. Our experimental results demonstrate the utility of the derived criteria with a success rate in entanglement detection of ˜60 % relative to 7344 studied cases.

  1. A pilot study on the use of geometrically accurate face models to replicate ex vivo N95 mask fit.

    PubMed

    Golshahi, Laleh; Telidetzki, Karla; King, Ben; Shaw, Diana; Finlay, Warren H

    2013-01-01

    To test the feasibility of replicating a face mask seal in vitro, we created 5 geometrically accurate reconstructions of the head and neck of an adult human subject using different materials. Three breathing patterns were simulated with each replica and an attached N95 mask. Quantitative fit testing on the subject and the replicas showed that none of the 5 isotropic materials used allowed duplication of the ex vivo mask seal for the specific mask-face combination studied. Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  2. Variability metrics in Josephson Junction fabrication for Quantum Computing circuits

    NASA Astrophysics Data System (ADS)

    Rosenblatt, Sami; Hertzberg, Jared; Brink, Markus; Chow, Jerry; Gambetta, Jay; Leng, Zhaoqi; Houck, Andrew; Nelson, J. J.; Plourde, Britton; Wu, Xian; Lake, Russell; Shainline, Jeff; Pappas, David; Patel, Umeshkumar; McDermott, Robert

    Multi-qubit gates depend on the relative frequencies of the qubits. To reliably build multi-qubit devices therefore requires careful fabrication of Josephson junctions in order to precisely set their critical currents. The Ambegaokar-Baratoff relation between tunnel conductance and critical current implies a correlation between qubit frequency spread and tunnel junction resistance spread. Here we discuss measurement of large numbers of tunnel junctions to assess these resistance spreads, which can exceed 5% of mean resistance. With the goal of minimizing these spreads, we investigate process parameters such as lithographic junction area, evaporation and masking scheme, oxidation conditions, and substrate choice, as well as test environment, design and setup. In addition, trends of junction resistance with temperature are compared with theoretical models for further insights into process and test variability.

  3. EUV mask manufacturing readiness in the merchant mask industry

    NASA Astrophysics Data System (ADS)

    Green, Michael; Choi, Yohan; Ham, Young; Kamberian, Henry; Progler, Chris; Tseng, Shih-En; Chiou, Tsann-Bim; Miyazaki, Junji; Lammers, Ad; Chen, Alek

    2017-10-01

    As nodes progress into the 7nm and below regime, extreme ultraviolet lithography (EUVL) becomes critical for all industry participants interested in remaining at the leading edge. One key cost driver for EUV in the supply chain is the reflective EUV mask. As of today, the relatively few end users of EUV consist primarily of integrated device manufactures (IDMs) and foundries that have internal (captive) mask manufacturing capability. At the same time, strong and early participation in EUV by the merchant mask industry should bring value to these chip makers, aiding the wide-scale adoption of EUV in the future. For this, merchants need access to high quality, representative test vehicles to develop and validate their own processes. This business circumstance provides the motivation for merchants to form Joint Development Partnerships (JDPs) with IDMs, foundries, Original Equipment Manufacturers (OEMs) and other members of the EUV supplier ecosystem that leverage complementary strengths. In this paper, we will show how, through a collaborative supplier JDP model between a merchant and OEM, a novel, test chip driven strategy is applied to guide and validate mask level process development. We demonstrate how an EUV test vehicle (TV) is generated for mask process characterization in advance of receiving chip maker-specific designs. We utilize the TV to carry out mask process "stress testing" to define process boundary conditions which can be used to create Mask Rule Check (MRC) rules as well as serve as baseline conditions for future process improvement. We utilize Advanced Mask Characterization (AMC) techniques to understand process capability on designs of varying complexity that include EUV OPC models with and without sub-resolution assist features (SRAFs). Through these collaborations, we demonstrate ways to develop EUV processes and reduce implementation risks for eventual mass production. By reducing these risks, we hope to expand access to EUV mask capability for the broadest community possible as the technology is implemented first within and then beyond the initial early adopters.

  4. Maxillary Protraction With Intermaxillary Elastics to Miniplates Versus Bone-Anchored Face-Mask Therapy in Cleft Lip and Palate Patients.

    PubMed

    Jahanbin, Arezoo; Kazemian, Mozhgan; Eslami, Neda; Pouya, Iman Saeedi

    2016-07-01

    Cleft lip and palate patients usually have deficient maxilla due to postsurgical scars. The aim this study was to compare the effectiveness of miniplates-anchored face-mask therapy versus intermaxillary elastics to miniplates for maxillary traction in cleft lip and palate patients. This clinical trial included 11 prepubertal patients with cleft lip and palate. Initially, a w-arch expander was cemented and activated 3 mm per month to overcorrect the crossbite. Then, the patients were divided into 2 groups: mini-plate-anchored face-mask (n = 5): 2 miniplates were placed in the maxilla and the patients were instructed to wear a face-mask for 12 to 14 hours/per day. Intermaxillary elastics to miniplates (n = 6): 2 miniplates were inserted in the maxilla; 1 on each side and 2 miniplates were placed in the anterior mandible on both sides. Intermaxillary elastics with a force of 250 g per side were attached to the hooks. Cephalometric parameters before treatment (T1) and after achieving positive overjet (T2) were compared between the 2 groups. Fisher exact, paired, and independent t tests were used for statistical comparison. At T1 or T2 there was not a significant difference between the 2 groups in the skeletal, dental, and soft tissue variables. According to results of our preliminary study, intermaxillary elastics to miniplates might have a promising effect as an alternative for face mask therapy in maxillary protraction of cleft lip and palate patients.

  5. An experimental investigation of masking in the US FDA adverse event reporting system database.

    PubMed

    Wang, Hsin-wei; Hochberg, Alan M; Pearson, Ronald K; Hauben, Manfred

    2010-12-01

    A phenomenon of 'masking' or 'cloaking' in pharmacovigilance data mining has been described, which can potentially cause signals of disproportionate reporting (SDRs) to be missed, particularly in pharmaceutical company databases. Masking has been predicted theoretically, observed anecdotally or studied to a limited extent in both pharmaceutical company and health authority databases, but no previous publication systematically assesses its occurrence in a large health authority database. To explore the nature, extent and possible consequences of masking in the US FDA Adverse Event Reporting System (AERS) database by applying various experimental unmasking protocols to a set of drugs and events representing realistic pharmacovigilance analysis conditions. This study employed AERS data from 2001 through 2005. For a set of 63 Medical Dictionary for Regulatory Activities (MedDRA®) Preferred Terms (PTs), disproportionality analysis was carried out with respect to all drugs included in the AERS database, using a previously described urn-model-based algorithm. We specifically sought masking in which drug removal induced an increase in the statistical representation of a drug-event combination (DEC) that resulted in the emergence of a new SDR. We performed a series of unmasking experiments selecting drugs for removal using rational statistical decision rules based on the requirement of a reporting ratio (RR) >1, top-ranked statistical unexpectedness (SU) and relatedness as reflected in the WHO Anatomical Therapeutic Chemical level 4 (ATC4) grouping. In order to assess the possible extent of residual masking we performed two supplemental purely empirical analyses on a limited subset of data. This entailed testing every drug and drug group to determine which was most influential in uncovering masked SDRs. We assessed the strength of external evidence for a causal association for a small number of masked SDRs involving a subset of 29 drugs for which level of evidence adjudication was available from a previous study. The original disproportionality analysis identified 8719 SDRs for the 63 PTs. The SU-based unmasking protocols generated variable numbers of masked SDRs ranging from 38 to 156, representing a 0.43-1.8% increase over the number of baseline SDRs. A significant number of baseline SDRs were also lost in the course of our experiments. The trend in the number of gained SDRs per report removed was inversely related to the number of lost SDRs per protocol. Both the number and nature of the reports removed influenced the number of gained SDRs observed. The purely empirical protocols unmasked up to ten times as many SDRs. None of the masked SDRs had strong external evidence supporting a causal association. Most involved associations for which there was no external supporting evidence or were in the original product label. For two masked SDRs, there was external evidence of a possible causal association. We documented masking in the FDA AERS database. Attempts at unmasking SDRs using practically implementable protocols produced only small changes in the output of SDRs in our analysis. This is undoubtedly related to the large size and diversity of the database, but the complex interdependencies between drugs and events in authentic spontaneous reporting system (SRS) databases, and the impact of measures of statistical variability that are typically used in real-world disproportionality analysis, may be additional factors that constrain the discovery of masked SDRs and which may also operate in pharmaceutical company databases. Empirical determination of the most influential drugs may uncover significantly more SDRs than protocols based on predetermined statistical selection rules but are impractical except possibly for evaluating specific events. Routine global exercises to elicit masking, especially in large health authority databases are not justified based on results available to date. Exercises to elicit unmasking should be driven by prior knowledge or obvious data imbalances.

  6. The impact of 14nm photomask variability and uncertainty on computational lithography solutions

    NASA Astrophysics Data System (ADS)

    Sturtevant, John; Tejnil, Edita; Buck, Peter D.; Schulze, Steffen; Kalk, Franklin; Nakagawa, Kent; Ning, Guoxiang; Ackmann, Paul; Gans, Fritz; Buergel, Christian

    2013-09-01

    Computational lithography solutions rely upon accurate process models to faithfully represent the imaging system output for a defined set of process and design inputs. These models rely upon the accurate representation of multiple parameters associated with the scanner and the photomask. Many input variables for simulation are based upon designed or recipe-requested values or independent measurements. It is known, however, that certain measurement methodologies, while precise, can have significant inaccuracies. Additionally, there are known errors associated with the representation of certain system parameters. With shrinking total CD control budgets, appropriate accounting for all sources of error becomes more important, and the cumulative consequence of input errors to the computational lithography model can become significant. In this work, we examine via simulation, the impact of errors in the representation of photomask properties including CD bias, corner rounding, refractive index, thickness, and sidewall angle. The factors that are most critical to be accurately represented in the model are cataloged. CD bias values are based on state of the art mask manufacturing data and other variables changes are speculated, highlighting the need for improved metrology and communication between mask and OPC model experts. The simulations are done by ignoring the wafer photoresist model, and show the sensitivity of predictions to various model inputs associated with the mask. It is shown that the wafer simulations are very dependent upon the 1D/2D representation of the mask and for 3D, that the mask sidewall angle is a very sensitive factor influencing simulated wafer CD results.

  7. Masking Period Patterns & Forward Masking for Speech-Shaped Noise: Age-related effects

    PubMed Central

    Grose, John H.; Menezes, Denise C.; Porter, Heather L.; Griz, Silvana

    2015-01-01

    Objective The purpose of this study was to assess age-related changes in temporal resolution in listeners with relatively normal audiograms. The hypothesis was that increased susceptibility to non-simultaneous masking contributes to the hearing difficulties experienced by older listeners in complex fluctuating backgrounds. Design Participants included younger (n = 11), middle-aged (n = 12), and older (n = 11) listeners with relatively normal audiograms. The first phase of the study measured masking period patterns for speech-shaped noise maskers and signals. From these data, temporal window shapes were derived. The second phase measured forward-masking functions, and assessed how well the temporal window fits accounted for these data. Results The masking period patterns demonstrated increased susceptibility to backward masking in the older listeners, compatible with a more symmetric temporal window in this group. The forward-masking functions exhibited an age-related decline in recovery to baseline thresholds, and there was also an increase in the variability of the temporal window fits to these data. Conclusions This study demonstrated an age-related increase in susceptibility to non-simultaneous masking, supporting the hypothesis that exacerbated non-simultaneous masking contributes to age-related difficulties understanding speech in fluctuating noise. Further support for this hypothesis comes from limited speech-in-noise data suggesting an association between susceptibility to forward masking and speech understanding in modulated noise. PMID:26230495

  8. Speech-evoked Brainstem Auditory Responses and Auditory Processing Skills: A Correlation in Adults with Hearing Loss

    PubMed Central

    Sanguebuche, Taissane Rodrigues; Peixe, Bruna Pias; Bruno, Rúbia Soares; Biaggio, Eliara Pinto Vieira; Garcia, Michele Vargas

    2018-01-01

    Introduction  The auditory system consists of sensory structures and central connections. The evaluation of the auditory pathway at a central level can be performed through behavioral and electrophysiological tests, because they are complementary to each other and provide important information about comprehension. Objective  To correlate the findings of speech brainstem-evoked response audiometry with the behavioral tests Random Gap Detection Test and Masking Level Difference in adults with hearing loss. Methods  All patients were submitted to a basic audiological evaluation, to the aforementioned behavioral tests, and to an electrophysiological assessment, by means of click-evoked and speech-evoked brainstem response audiometry. Results  There were no statistically significant values among the electrophysiological test and the behavioral tests. However, there was a significant correlation between the V and A waves, as well as the D and F waves, of the speech-evoked brainstem response audiometry peaks. Such correlations are positive, indicating that the increase of a variable implies an increase in another and vice versa. Conclusion  It was possible to correlate the findings of the speech-evoked brainstem response audiometry with those of the behavioral tests Random Gap Detection and Masking Level Difference. However, there was no statistically significant correlation between them. This shows that the electrophysiological evaluation does not depend uniquely on the behavioral skills of temporal resolution and selective attention. PMID:29379574

  9. Attentional Modulation of Masked Repetition and Categorical Priming in Young and Older Adults

    ERIC Educational Resources Information Center

    Fabre, Ludovic; Lemaire, Patrick; Grainger, Jonathan

    2007-01-01

    Three experiments examined the effects of temporal attention and aging on masked repetition and categorical priming for numbers and words. Participants' temporal attention was manipulated by varying the stimulus onset asynchrony (i.e., constant or variable SOA). In Experiment 1, participants performed a parity judgment task and a lexical decision…

  10. Assessment of a respiratory face mask for capturing air pollutants and pathogens including human influenza and rhinoviruses.

    PubMed

    Zhou, S Steve; Lukula, Salimatu; Chiossone, Cory; Nims, Raymond W; Suchmann, Donna B; Ijaz, M Khalid

    2018-03-01

    Prevention of infection with airborne pathogens and exposure to airborne particulates and aerosols (environmental pollutants and allergens) can be facilitated through use of disposable face masks. The effectiveness of such masks for excluding pathogens and pollutants is dependent on the intrinsic ability of the masks to resist penetration by airborne contaminants. This study evaluated the relative contributions of a mask, valve, and Micro Ventilator on aerosol filtration efficiency of a new N95 respiratory face mask. The test mask was challenged, using standardized methods, with influenza A and rhinovirus type 14, bacteriophage ΦΧ174, Staphylococcus aureus ( S . aureus ), and model pollutants. The statistical significance of results obtained for different challenge microbial agents and for different mask configurations (masks with operational or nonoperational ventilation fans and masks with sealed Smart Valves) was assessed. The results demonstrate >99.7% efficiency of each test mask configuration for exclusion of influenza A virus, rhinovirus 14, and S . aureus and >99.3% efficiency for paraffin oil and sodium chloride (surrogates for PM 2.5 ). Statistically significant differences in effectiveness of the different mask configurations were not identified. The efficiencies of the masks for excluding smaller-size (i.e., rhinovirus and bacteriophage ΦΧ174) vs. larger-size microbial agents (influenza virus, S . aureus ) were not significantly different. The masks, with or without features intended for enhancing comfort, provide protection against both small- and large-size pathogens. Importantly, the mask appears to be highly efficient for filtration of pathogens, including influenza and rhinoviruses, as well as the fine particulates (PM 2.5 ) present in aerosols that represent a greater challenge for many types of dental and surgical masks. This renders this individual-use N95 respiratory mask an improvement over the former types of masks for protection against a variety of environmental contaminants including PM 2.5 and pathogens such as influenza and rhinoviruses.

  11. Assessment of a respiratory face mask for capturing air pollutants and pathogens including human influenza and rhinoviruses

    PubMed Central

    Zhou, S. Steve; Lukula, Salimatu; Chiossone, Cory; Nims, Raymond W.; Suchmann, Donna B.

    2018-01-01

    Background Prevention of infection with airborne pathogens and exposure to airborne particulates and aerosols (environmental pollutants and allergens) can be facilitated through use of disposable face masks. The effectiveness of such masks for excluding pathogens and pollutants is dependent on the intrinsic ability of the masks to resist penetration by airborne contaminants. This study evaluated the relative contributions of a mask, valve, and Micro Ventilator on aerosol filtration efficiency of a new N95 respiratory face mask. Methods The test mask was challenged, using standardized methods, with influenza A and rhinovirus type 14, bacteriophage ΦΧ174, Staphylococcus aureus (S. aureus), and model pollutants. The statistical significance of results obtained for different challenge microbial agents and for different mask configurations (masks with operational or nonoperational ventilation fans and masks with sealed Smart Valves) was assessed. Results The results demonstrate >99.7% efficiency of each test mask configuration for exclusion of influenza A virus, rhinovirus 14, and S. aureus and >99.3% efficiency for paraffin oil and sodium chloride (surrogates for PM2.5). Statistically significant differences in effectiveness of the different mask configurations were not identified. The efficiencies of the masks for excluding smaller-size (i.e., rhinovirus and bacteriophage ΦΧ174) vs. larger-size microbial agents (influenza virus, S. aureus) were not significantly different. Conclusions The masks, with or without features intended for enhancing comfort, provide protection against both small- and large-size pathogens. Importantly, the mask appears to be highly efficient for filtration of pathogens, including influenza and rhinoviruses, as well as the fine particulates (PM2.5) present in aerosols that represent a greater challenge for many types of dental and surgical masks. This renders this individual-use N95 respiratory mask an improvement over the former types of masks for protection against a variety of environmental contaminants including PM2.5 and pathogens such as influenza and rhinoviruses. PMID:29707364

  12. Performance of ICU ventilators during noninvasive ventilation with large leaks in a total face mask: a bench study.

    PubMed

    Nakamura, Maria Aparecida Miyuki; Costa, Eduardo Leite Vieira; Carvalho, Carlos Roberto Ribeiro; Tucci, Mauro Roberto

    2014-01-01

    Discomfort and noncompliance with noninvasive ventilation (NIV) interfaces are obstacles to NIV success. Total face masks (TFMs) are considered to be a very comfortable NIV interface. However, due to their large internal volume and consequent increased CO2 rebreathing, their orifices allow proximal leaks to enhance CO2 elimination. The ventilators used in the ICU might not adequately compensate for such leakage. In this study, we attempted to determine whether ICU ventilators in NIV mode are suitable for use with a leaky TFM. This was a bench study carried out in a university research laboratory. Eight ICU ventilators equipped with NIV mode and one NIV ventilator were connected to a TFM with major leaks. All were tested at two positive end-expiratory pressure (PEEP) levels and three pressure support levels. The variables analyzed were ventilation trigger, cycling off, total leak, and pressurization. Of the eight ICU ventilators tested, four did not work (autotriggering or inappropriate turning off due to misdetection of disconnection); three worked with some problems (low PEEP or high cycling delay); and one worked properly. The majority of the ICU ventilators tested were not suitable for NIV with a leaky TFM.

  13. Reading a standing wave: figure-ground-alternation masking of primes in evaluative priming.

    PubMed

    Bermeitinger, Christina; Kuhlmann, Michael; Wentura, Dirk

    2012-09-01

    We propose a new masking technique for masking word stimuli. Drawing on the phenomena of metacontrast and paracontrast, we alternately presented two prime displays of the same word with the background color in one display matching the font color in the other display and vice versa. The sequence of twenty alterations (spanning approx. 267 ms) was sandwich-masked by structure masks. Using this masking technique, we conducted evaluative priming experiments with positive and negative target and prime words. Significant priming effects were found - for primes and targets drawn from the same as well as from different word sets. Priming effects were independent of prime discrimination performance in direct tests and they were still significant after the sample was restricted to those participants who showed random responding in the direct test. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. Dynamics of normalization underlying masking in human visual cortex.

    PubMed

    Tsai, Jeffrey J; Wade, Alex R; Norcia, Anthony M

    2012-02-22

    Stimulus visibility can be reduced by other stimuli that overlap the same region of visual space, a process known as masking. Here we studied the neural mechanisms of masking in humans using source-imaged steady state visual evoked potentials and frequency-domain analysis over a wide range of relative stimulus strengths of test and mask stimuli. Test and mask stimuli were tagged with distinct temporal frequencies and we quantified spectral response components associated with the individual stimuli (self terms) and responses due to interaction between stimuli (intermodulation terms). In early visual cortex, masking alters the self terms in a manner consistent with a reduction of input contrast. We also identify a novel signature of masking: a robust intermodulation term that peaks when the test and mask stimuli have equal contrast and disappears when they are widely different. We fit all of our data simultaneously with family of a divisive gain control models that differed only in their dynamics. Models with either very short or very long temporal integration constants for the gain pool performed worse than a model with an integration time of ∼30 ms. Finally, the absolute magnitudes of the response were controlled by the ratio of the stimulus contrasts, not their absolute values. This contrast-contrast invariance suggests that many neurons in early visual cortex code relative rather than absolute contrast. Together, these results provide a more complete description of masking within the normalization framework of contrast gain control and suggest that contrast normalization accomplishes multiple functional goals.

  15. Multi-shaped beam: development status and update on lithography results

    NASA Astrophysics Data System (ADS)

    Slodowski, Matthias; Doering, Hans-Joachim; Dorl, Wolfgang; Stolberg, Ines A.

    2011-04-01

    According to the ITRS [1] photo mask is a significant challenge for the 22nm technology node requirements and beyond. Mask making capability and cost escalation continue to be critical for future lithography progress. On the technological side mask specifications and complexity have increased more quickly than the half-pitch requirements on the wafer designated by the roadmap due to advanced optical proximity correction and double patterning demands. From the economical perspective mask costs have significantly increased each generation, in which mask writing represents a major portion. The availability of a multi-electron-beam lithography system for mask write application is considered a potential solution to overcome these challenges [2, 3]. In this paper an update of the development status of a full-package high-throughput multi electron-beam writer, called Multi Shaped Beam (MSB), will be presented. Lithography performance results, which are most relevant for mask writing applications, will be disclosed. The MSB technology is an evolutionary development of the matured single Variable Shaped Beam (VSB) technology. An arrangement of Multi Deflection Arrays (MDA) allows operation with multiple shaped beams of variable size, which can be deflected and controlled individually [4]. This evolutionary MSB approach is associated with a lower level of risk and a relatively short time to implementation compared to the known revolutionary concepts [3, 5, 6]. Lithography performance is demonstrated through exposed pattern. Further details of the substrate positioning platform performance will be disclosed. It will become apparent that the MSB operational mode enables lithography on the same and higher performance level compared to single VSB and that there are no specific additional lithography challenges existing beside those which have already been addressed [1].

  16. Masking with faces in central visual field under a variety of temporal schedules.

    PubMed

    Daar, Marwan; Wilson, Hugh R

    2015-11-01

    With a few exceptions, previous studies have explored masking using either a backward mask or a common onset trailing mask, but not both. In a series of experiments, we demonstrate the use of faces in central visual field as a viable method to study the relationship between these two types of mask schedule. We tested observers in a two alternative forced choice face identification task, where both target and mask comprised synthetic faces, and show that a simple model can successfully predict masking across a variety of masking schedules ranging from a backward mask to a common onset trailing mask and a number of intermediate variations. Our data are well accounted for by a window of sensitivity to mask interference that is centered at around 100 ms. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. A masking level difference due to harmonicity.

    PubMed

    Treurniet, W C; Boucher, D R

    2001-01-01

    The role of harmonicity in masking was studied by comparing the effect of harmonic and inharmonic maskers on the masked thresholds of noise probes using a three-alternative, forced-choice method. Harmonic maskers were created by selecting sets of partials from a harmonic series with an 88-Hz fundamental and 45 consecutive partials. Inharmonic maskers differed in that the partial frequencies were perturbed to nearby values that were not integer multiples of the fundamental frequency. Average simultaneous-masked thresholds were as much as 10 dB lower with the harmonic masker than with the inharmonic masker, and this difference was unaffected by masker level. It was reduced or eliminated when the harmonic partials were separated by more than 176 Hz, suggesting that the effect is related to the extent to which the harmonics are resolved by auditory filters. The threshold difference was not observed in a forward-masking experiment. Finally, an across-channel mechanism was implicated when the threshold difference was found between a harmonic masker flanked by harmonic bands and a harmonic masker flanked by inharmonic bands. A model developed to explain the observed difference recognizes that an auditory filter output envelope is modulated when the filter passes two or more sinusoids, and that the modulation rate depends on the differences among the input frequencies. For a harmonic masker, the frequency differences of adjacent partials are identical, and all auditory filters have the same dominant modulation rate. For an inharmonic masker, however, the frequency differences are not constant and the envelope modulation rate varies across filters. The model proposes that a lower variability facilitates detection of a probe-induced change in the variability, thus accounting for the masked threshold difference. The model was supported by significantly improved predictions of observed thresholds when the predictor variables included envelope modulation rate variance measured using simulated auditory filters.

  18. Interactions between concentric form-from-structure and face perception revealed by visual masking but not adaptation

    PubMed Central

    Feczko, Eric; Shulman, Gordon L.; Petersen, Steven E.; Pruett, John R.

    2014-01-01

    Findings from diverse subfields of vision research suggest a potential link between high-level aspects of face perception and concentric form-from-structure perception. To explore this relationship, typical adults performed two adaptation experiments and two masking experiments to test whether concentric, but not nonconcentric, Glass patterns (a type of form-from-structure stimulus) utilize a processing mechanism shared by face perception. For the adaptation experiments, subjects were presented with an adaptor for 5 or 20 s, prior to discriminating a target. In the masking experiments, subjects saw a mask, then a target, and then a second mask. Measures of discriminability and bias were derived and repeated measures analysis of variance tested for pattern-specific masking and adaptation effects. Results from Experiment 1 show no Glass pattern-specific effect of adaptation to faces; results from Experiment 2 show concentric Glass pattern masking, but not adaptation, may impair upright/inverted face discrimination; results from Experiment 3 show concentric and radial Glass pattern masking impaired subsequent upright/inverted face discrimination more than translational Glass pattern masking; and results from Experiment 4 show concentric and radial Glass pattern masking impaired subsequent face gender discrimination more than translational Glass pattern masking. Taken together, these findings demonstrate interactions between concentric form-from-structure and face processing, suggesting a possible common processing pathway. PMID:24563526

  19. On the effectiveness of noise masks: naturalistic vs. un-naturalistic image statistics.

    PubMed

    Hansen, Bruce C; Hess, Robert F

    2012-05-01

    It has been argued that the human visual system is optimized for identification of broadband objects embedded in stimuli possessing orientation averaged power spectra fall-offs that obey the 1/f(β) relationship typically observed in natural scene imagery (i.e., β=2.0 on logarithmic axes). Here, we were interested in whether individual spatial channels leading to recognition are functionally optimized for narrowband targets when masked by noise possessing naturalistic image statistics (β=2.0). The current study therefore explores the impact of variable β noise masks on the identification of narrowband target stimuli ranging in spatial complexity, while simultaneously controlling for physical or perceived differences between the masks. The results show that β=2.0 noise masks produce the largest identification thresholds regardless of target complexity, and thus do not seem to yield functionally optimized channel processing. The differential masking effects are discussed in the context of contrast gain control. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. Nonconscious attention bias to threat is correlated with anterior cingulate cortex gray matter volume: a voxel-based morphometry result and replication.

    PubMed

    Carlson, Joshua M; Beacher, Felix; Reinke, Karen S; Habib, Reza; Harmon-Jones, Eddie; Mujica-Parodi, Lilianne R; Hajcak, Greg

    2012-01-16

    An important aspect of the fear response is the allocation of spatial attention toward threatening stimuli. This response is so powerful that modulations in spatial attention can occur automatically without conscious awareness. Functional neuroimaging research suggests that the amygdala and anterior cingulate cortex (ACC) form a network involved in the rapid orienting of attention to threat. A hyper-responsive attention bias to threat is a common component of anxiety disorders. Yet, little is known of how individual differences in underlying brain morphometry relate to variability in attention bias to threat. Here, we performed two experiments using dot-probe tasks that measured individuals' attention bias to backward masked fearful faces. We collected whole-brain structural magnetic resonance images and used voxel-based morphometry to measure brain morphometry. We tested the hypothesis that reduced gray matter within the amygdala and ACC would be associated with reduced attention bias to threat. In Experiment 1, we found that backward masked fearful faces captured spatial attention and that elevated attention bias to masked threat was associated with greater ACC gray matter volumes. In Experiment 2, this association was replicated in a separate sample. Thus, we provide initial and replicating evidence that ACC gray matter volume is correlated with biased attention to threat. Importantly, we demonstrate that variability in affective attention bias within the healthy population is associated with ACC morphometry. This result opens the door for future research into the underlying brain morphometry associated with attention bias in clinically anxious populations. Copyright © 2011 Elsevier Inc. All rights reserved.

  1. A simple signaling rule for variable life-adjusted display derived from an equivalent risk-adjusted CUSUM chart.

    PubMed

    Wittenberg, Philipp; Gan, Fah Fatt; Knoth, Sven

    2018-04-17

    The variable life-adjusted display (VLAD) is the first risk-adjusted graphical procedure proposed in the literature for monitoring the performance of a surgeon. It displays the cumulative sum of expected minus observed deaths. It has since become highly popular because the statistic plotted is easy to understand. But it is also easy to misinterpret a surgeon's performance by utilizing the VLAD, potentially leading to grave consequences. The problem of misinterpretation is essentially caused by the variance of the VLAD's statistic that increases with sample size. In order for the VLAD to be truly useful, a simple signaling rule is desperately needed. Various forms of signaling rules have been developed, but they are usually quite complicated. Without signaling rules, making inferences using the VLAD alone is difficult if not misleading. In this paper, we establish an equivalence between a VLAD with V-mask and a risk-adjusted cumulative sum (RA-CUSUM) chart based on the difference between the estimated probability of death and surgical outcome. Average run length analysis based on simulation shows that this particular RA-CUSUM chart has similar performance as compared to the established RA-CUSUM chart based on the log-likelihood ratio statistic obtained by testing the odds ratio of death. We provide a simple design procedure for determining the V-mask parameters based on a resampling approach. Resampling from a real data set ensures that these parameters can be estimated appropriately. Finally, we illustrate the monitoring of a real surgeon's performance using VLAD with V-mask. Copyright © 2018 John Wiley & Sons, Ltd.

  2. Agricultural resources investigations in northern Italy and southern France (Agreste project). Part 1: Activity performed on the Italian test-sites

    NASA Technical Reports Server (NTRS)

    Megier, J. (Principal Investigator)

    1976-01-01

    The author has identified the following significant results. Some qualitative results were obtained out of the experiment of reflectance measurements under greenhouse conditions. An effort was made to correlate phenological stages, production, and radiometric measurements. It was found that the first order effect of exposure variability to sun irradiation is responsible for different rice productivity classes. Effects of rice variety and fertilization become second order, because they are completely masked by the first order effects.

  3. Mask CD relationship to temperature at the time backscatter is received

    NASA Astrophysics Data System (ADS)

    Zable, Harold; Kronmiller, Tom; Pearman, Ryan; Guthrie, Bill; Shirali, Nagesh; Masuda, Yukihiro; Kamikubo, Takashi; Nakayamada, Noriaki; Fujimura, Aki

    2017-07-01

    Mask writers need to be able to write sub-50nm features accurately. Nano-imprint lithography (NIL) masters need to create sub-20nm line and space (L:S) patterns reliably. Increasingly slower resists are deployed, but mask write times need to remain reasonable. The leading edge EBM-9500 offers 1200A/cm2 current density to shoot variable shaped beam (VSB) to write the masks. Last year, thermal effect correction (TEC) was introduced by NuFlare in the EBM-95001. It is a GPU-accelerated inline correction for the effect that the temperature of the resist has on CD. For example, a 100nm CD may print at 102nm where that area was at a comparably high temperature at the time of the shot. Since thermal effect is a temporal effect, the simulated temperature of the surface of the mask is dynamically updated for the effect of each shot in order to accurately predict the cumulative effect that is the temperature at the location of the shot at the time of the shot and therefore its impact on CD. The shot dose is changed to reverse the effects of the temperature change. This paper for the first time reveals an enhancement to this thermal model and a simulator for it. It turns out that the temperature at the time each location receives backscatter from other shots also make a difference to the CD. The effect is secondary, but still measurable for some resists and substrates. Results of a test-chip study will be presented. The computation required for the backscatter effect is substantial. It has been demonstrated that this calculation can be performed fast enough to be inline with the EBM-9500 with a reasonable-sized computing platform. Run-time results and the computing architecture will be presented.

  4. Bubble masks for time-encoded imaging of fast neutrons.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brubaker, Erik; Brennan, James S.; Marleau, Peter

    2013-09-01

    Time-encoded imaging is an approach to directional radiation detection that is being developed at SNL with a focus on fast neutron directional detection. In this technique, a time modulation of a detected neutron signal is inducedtypically, a moving mask that attenuates neutrons with a time structure that depends on the source position. An important challenge in time-encoded imaging is to develop high-resolution two-dimensional imaging capabilities; building a mechanically moving high-resolution mask presents challenges both theoretical and technical. We have investigated an alternative to mechanical masks that replaces the solid mask with a liquid such as mineral oil. Instead of fixedmore » blocks of solid material that move in pre-defined patterns, the oil is contained in tubing structures, and carefully introduced air gapsbubblespropagate through the tubing, generating moving patterns of oil mask elements and air apertures. Compared to current moving-mask techniques, the bubble mask is simple, since mechanical motion is replaced by gravity-driven bubble propagation; it is flexible, since arbitrary bubble patterns can be generated by a software-controlled valve actuator; and it is potentially high performance, since the tubing and bubble size can be tuned for high-resolution imaging requirements. We have built and tested various single-tube mask elements, and will present results on bubble introduction and propagation as a function of tubing size and cross-sectional shape; real-time bubble position tracking; neutron source imaging tests; and reconstruction techniques demonstrated on simple test data as well as a simulated full detector system.« less

  5. Automated mask and wafer defect classification using a novel method for generalized CD variation measurements

    NASA Astrophysics Data System (ADS)

    Verechagin, V.; Kris, R.; Schwarzband, I.; Milstein, A.; Cohen, B.; Shkalim, A.; Levy, S.; Price, D.; Bal, E.

    2018-03-01

    Over the years, mask and wafers defects dispositioning has become an increasingly challenging and time consuming task. With design rules getting smaller, OPC getting complex and scanner illumination taking on free-form shapes - the probability of a user to perform accurate and repeatable classification of defects detected by mask inspection tools into pass/fail bins is reducing. The critical challenging of mask defect metrology for small nodes ( < 30 nm) was reviewed in [1]. While Critical Dimension (CD) variation measurement is still the method of choice for determining a mask defect future impact on wafer, the high complexity of OPCs combined with high variability in pattern shapes poses a challenge for any automated CD variation measurement method. In this study, a novel approach for measurement generalization is presented. CD variation assessment performance is evaluated on multiple different complex shape patterns, and is benchmarked against an existing qualified measurement methodology.

  6. Comparison of arterial spin labeling registration strategies in the multi-center GENetic frontotemporal dementia initiative (GENFI).

    PubMed

    Mutsaerts, Henri J M M; Petr, Jan; Thomas, David L; De Vita, Enrico; Cash, David M; van Osch, Matthias J P; Golay, Xavier; Groot, Paul F C; Ourselin, Sebastien; van Swieten, John; Laforce, Robert; Tagliavini, Fabrizio; Borroni, Barbara; Galimberti, Daniela; Rowe, James B; Graff, Caroline; Pizzini, Francesca B; Finger, Elizabeth; Sorbi, Sandro; Castelo Branco, Miguel; Rohrer, Jonathan D; Masellis, Mario; MacIntosh, Bradley J

    2018-01-01

    To compare registration strategies to align arterial spin labeling (ASL) with 3D T1-weighted (T1w) images, with the goal of reducing the between-subject variability of cerebral blood flow (CBF) images. Multi-center 3T ASL data were collected at eight sites with four different sequences in the multi-center GENetic Frontotemporal dementia Initiative (GENFI) study. In a total of 48 healthy controls, we compared the following image registration options: (I) which images to use for registration (perfusion-weighted images [PWI] to the segmented gray matter (GM) probability map (pGM) (CBF-pGM) or M0 to T1w (M0-T1w); (II) which transformation to use (rigid-body or non-rigid); and (III) whether to mask or not (no masking, M0-based FMRIB software library Brain Extraction Tool [BET] masking). In addition to visual comparison, we quantified image similarity using the Pearson correlation coefficient (CC), and used the Mann-Whitney U rank sum test. CBF-pGM outperformed M0-T1w (CC improvement 47.2% ± 22.0%; P < 0.001), and the non-rigid transformation outperformed rigid-body (20.6% ± 5.3%; P < 0.001). Masking only improved the M0-T1w rigid-body registration (14.5% ± 15.5%; P = 0.007). The choice of image registration strategy impacts ASL group analyses. The non-rigid transformation is promising but requires validation. CBF-pGM rigid-body registration without masking can be used as a default strategy. In patients with expansive perfusion deficits, M0-T1w may outperform CBF-pGM in sequences with high effective spatial resolution. BET-masking only improves M0-T1w registration when the M0 image has sufficient contrast. 1 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:131-140. © 2017 International Society for Magnetic Resonance in Medicine.

  7. On the impact of masking and blocking hypotheses for measuring the efficacy of new tuberculosis vaccines.

    PubMed

    Arregui, Sergio; Sanz, Joaquín; Marinova, Dessislava; Martín, Carlos; Moreno, Yamir

    2016-01-01

    Over the past 60 years, the Mycobacterium bovis bacille Calmette-Guérin (BCG) has been used worldwide to prevent tuberculosis (TB). However, BCG has shown a very variable efficacy in different trials, offering a wide range of protection in adults against pulmonary TB. One of the most accepted hypotheses to explain these inconsistencies points to the existence of a pre-existing immune response to antigens that are common to environmental sources of mycobacterial antigens and Mycobacterium tuberculosis. Specifically, two different mechanisms have been hypothesized to explain this phenomenon: the masking and the blocking effects. According to masking hypothesis, previous sensitization confers some level of protection against TB that masks vaccine's effects. In turn, the blocking hypothesis postulates that previous immune response prevents vaccine taking of a new TB vaccine. In this work we introduce a series of models to discriminate between masking and blocking mechanisms and address their relative likelihood. We apply our methodology to the data reported by BCG-REVAC clinical trials, which were specifically designed for studying BCG efficacy variability. Our results yield estimates that are consistent with high levels of blocking (41% in Manaus -95% CI [14-68]- and 96% in Salvador -95% CI [52-100]-). Moreover, we also show that masking does not play any relevant role in modifying vaccine's efficacy either alone or in addition to blocking. The quantification of these effects around a plausible model constitutes a relevant step towards impact evaluation of novel anti-tuberculosis vaccines, which are susceptible of being affected by similar effects, especially if applied on individuals previously exposed to mycobacterial antigens.

  8. Computerized Dead-Space Volume Measurement of Face Masks Applied to Simulated Faces.

    PubMed

    Amirav, Israel; Luder, Anthony S; Halamish, Asaf; Marzuk, Chatib; Daitzchman, Marcelo; Newhouse, Michael T

    2015-09-01

    The dead-space volume (VD) of face masks for metered-dose inhaler treatments is particularly important in infants and young children with asthma, who have relatively low tidal volumes. Data about VD have been traditionally obtained from water displacement measurements, in which masks are held against a flat surface. Because, in real life, masks are placed against the face, VD is likely to differ considerably between masks depending upon their contour and fit. The aim of this study was to develop an accurate and reliable way to measure VD electronically and to apply this technique by comparing the electronic VD of commonly available face masks. Average digital faces were obtained from 3-dimensional images of 270 infants and children. Commonly used face masks (small and medium) from various manufacturers (Monaghan Medical, Pari Respiratory Equipment, Philips Respironics, and InspiRx) were scanned and digitized by means of computed tomography. Each mask was electronically applied to its respective digital face, and the VD enclosed (mL) was computerized and precisely measured. VD varied between 22.6 mL (SootherMask, InspiRx) and 43.1 mL (Vortex, Pari) for small masks and between 41.7 mL (SootherMask) and 71.5 mL (AeroChamber, Monaghan Medical) for medium masks. These values were significantly lower and less variable than measurements obtained by water displacement. Computerized techniques provide an innovative and relatively simple way of accurately measuring the VD of face masks applied to digital faces. As determined by computerized measurement using average-size virtual faces, the InspiRx masks had a significantly smaller VD for both small and medium masks compared with the other masks. This is of considerable importance with respect to aerosol dose and delivery time, particularly in young children. (ClinicalTrials.gov registration NCT01274299.). Copyright © 2015 by Daedalus Enterprises.

  9. Bacterial cellulose skin masks-Properties and sensory tests.

    PubMed

    Pacheco, Guilherme; de Mello, Carolina Véspoli; Chiari-Andréo, Bruna Galdorfini; Isaac, Vera Lucia Borges; Ribeiro, Sidney José Lima; Pecoraro, Édison; Trovatti, Eliane

    2017-09-29

    Bacterial cellulose (BC) is a versatile material produced by microorganisms in the form of a membranous hydrogel, totally biocompatible, and endowed with high mechanical strength. Its high water-holding capacity based on its highly porous nanofibrillar structure allows BC to incorporate and to release substances very fast, thus being suitable for the preparation of skincare masks. The preparation and characterization of cosmetic masks based on BC membranes and active cosmetics. The masks were prepared by the simple incorporation of the cosmetic actives into BC membranes, used as a swelling matrix. The masks were characterized by Fourier transform infrared (FTIR), scanning electron microscopy (SEM), sensory tests, and skin moisture tests on volunteers. The results of sensory tests revealed the good performance of BC, being considered effective by the panel of volunteers, specially for adhesion to the skin (7.7 at the score scale), and improvement of the skin moisture (the hydration effect increased 76% in 75% of the volunteers that used vegetable extract mask formulation [VEM]), or a decrease in skin hydration (80% of the volunteers showed 32.6% decrease on skin hydration using propolis extract formulation [PEM] treatment), indicating the BC nanofiber membranes can be used to skincare applications. The results demonstrate the BC can be used as an alternative support for cosmetic actives for skin treatment. © 2017 Wiley Periodicals, Inc.

  10. Manufacturability study of masks created by inverse lithography technology (ILT)

    NASA Astrophysics Data System (ADS)

    Martin, Patrick M.; Progler, C. J.; Xiao, G.; Gray, R.; Pang, L.; Liu, Y.

    2005-11-01

    As photolithography is pushed to fabricate deep-sub wavelength devices for 90nm, 65nm and smaller technology nodes using available exposure tools (i.e., 248nm, 193nm steppers), photomask capability is becoming extremely critical. For example, PSM masks require more complicated processing; aggressive OPC makes the writing time longer and sometimes unpredictable; and, high MEEF imposes much more stringent demands on mask quality. Therefore, in order for any new lithography technology to be adopted into production, mask manufacturability must be studied thoroughly and carefully. In this paper we will present the mask manufacturability study on mask patterns created using Inverse Lithography Technology (ILT). Unlike conventional OPC methodologies, ILT uses a unique outcome-based technology to mathematically determine the mask features that produce the desired on-wafer results. ILT solves the most critical litho challenges of the deep sub-wavelength era. Potential benefits include: higher yield; expanded litho process windows; superb pattern fidelity at 90, 65 & 45-nm nodes; and reduced time-to-silicon - all without changing the existing lithography infrastructure and design-to-silicon flow. In this study a number of cell structures were selected and used as test patterns. "Luminized patterns" were generated for binary mask and attenuated phase-shift mask. Both conventional OPC patterns and "luminized patterns" were put on a test reticle side by side, and they all have a number of variations in term of correction aggressivity level and mask complexity. Mask manufacturability, including data fracturing, writing time, mask inspection, and metrology were studied. The results demonstrate that, by optimizing the inspection recipe, masks created using ILT technology can be made and qualified using current processes with a reasonable turn-around time.

  11. Mask process correction (MPC) modeling and its application to EUV mask for electron beam mask writer EBM-7000

    NASA Astrophysics Data System (ADS)

    Kamikubo, Takashi; Ohnishi, Takayuki; Hara, Shigehiro; Anze, Hirohito; Hattori, Yoshiaki; Tamamushi, Shuichi; Bai, Shufeng; Wang, Jen-Shiang; Howell, Rafael; Chen, George; Li, Jiangwei; Tao, Jun; Wiley, Jim; Kurosawa, Terunobu; Saito, Yasuko; Takigawa, Tadahiro

    2010-09-01

    In electron beam writing on EUV mask, it has been reported that CD linearity does not show simple signatures as observed with conventional COG (Cr on Glass) masks because they are caused by scattered electrons form EUV mask itself which comprises stacked heavy metals and thick multi-layers. To resolve this issue, Mask Process Correction (MPC) will be ideally applicable. Every pattern is reshaped in MPC. Therefore, the number of shots would not increase and writing time will be kept within reasonable range. In this paper, MPC is extended to modeling for correction of CD linearity errors on EUV mask. And its effectiveness is verified with simulations and experiments through actual writing test.

  12. Face mask use and control of respiratory virus transmission in households.

    PubMed

    MacIntyre, C Raina; Cauchemez, Simon; Dwyer, Dominic E; Seale, Holly; Cheung, Pamela; Browne, Gary; Fasher, Michael; Wood, James; Gao, Zhanhai; Booy, Robert; Ferguson, Neil

    2009-02-01

    Many countries are stockpiling face masks for use as a nonpharmaceutical intervention to control virus transmission during an influenza pandemic. We conducted a prospective cluster-randomized trial comparing surgical masks, non-fit-tested P2 masks, and no masks in prevention of influenza-like illness (ILI) in households. Mask use adherence was self-reported. During the 2006 and 2007 winter seasons, 286 exposed adults from 143 households who had been exposed to a child with clinical respiratory illness were recruited. We found that adherence to mask use significantly reduced the risk for ILI-associated infection, but <50% of participants wore masks most of the time. We concluded that household use of face masks is associated with low adherence and is ineffective for controlling seasonal respiratory disease. However, during a severe pandemic when use of face masks might be greater, pandemic transmission in households could be reduced.

  13. EUVL mask dual pods to be used for mask shipping and handling in exposure tools

    NASA Astrophysics Data System (ADS)

    Gomei, Yoshio; Ota, Kazuya; Lystad, John; Halbmair, Dave; He, Long

    2007-03-01

    The concept of Extreme Ultra-Violet Lithography (EUVL) mask dual pods is proposed for use in both mask shipping and handling in exposure tools. The inner pod was specially designed to protect masks from particle contamination during shipping from mask houses to wafer factories. It can be installed in a load-lock chamber of exposure tools and evacuated while holding the mask inside. The inner pod upper cover is removed just before the mask is installed to a mask stage. Prototypes were manufactured and tested for shipping and for vacuum cycling. We counted particle adders through these actions with a detectable level of 54 nm and up. The adder count was close to zero, or we can say that the obtained result is within the noise level of our present evaluation environment. This indicates that the present concept is highly feasible for EUVL mask shipping and handling in exposure tools.

  14. The Emergence of Visual Awareness: Temporal Dynamics in Relation to Task and Mask Type

    PubMed Central

    Kiefer, Markus; Kammer, Thomas

    2017-01-01

    One aspect of consciousness phenomena, the temporal emergence of visual awareness, has been subject of a controversial debate. How can visual awareness, that is the experiential quality of visual stimuli, be characterized best? Is there a sharp discontinuous or dichotomous transition between unaware and fully aware states, or does awareness emerge gradually encompassing intermediate states? Previous studies yielded conflicting results and supported both dichotomous and gradual views. It is well conceivable that these conflicting results are more than noise, but reflect the dynamic nature of the temporal emergence of visual awareness. Using a psychophysical approach, the present research tested whether the emergence of visual awareness is context-dependent with a temporal two-alternative forced choice task. During backward masking of word targets, it was assessed whether the relative temporal sequence of stimulus thresholds is modulated by the task (stimulus presence, letter case, lexical decision, and semantic category) and by mask type. Four masks with different similarity to the target features were created. Psychophysical functions were then fitted to the accuracy data in the different task conditions as a function of the stimulus mask SOA in order to determine the inflection point (conscious threshold of each feature) and slope of the psychophysical function (transition from unaware to aware within each feature). Depending on feature-mask similarity, thresholds in the different tasks were highly dispersed suggesting a graded transition from unawareness to awareness or had less differentiated thresholds indicating that clusters of features probed by the tasks quite simultaneously contribute to the percept. The latter observation, although not compatible with the notion of a sharp all-or-none transition between unaware and aware states, suggests a less gradual or more discontinuous emergence of awareness. Analyses of slopes of the fitted psychophysical functions also indicated that the emergence of awareness of single features is variable and might be influenced by the continuity of the feature dimensions. The present work thus suggests that the emergence of awareness is neither purely gradual nor dichotomous, but highly dynamic depending on the task and mask type. PMID:28316583

  15. System for interferometric distortion measurements that define an optical path

    DOEpatents

    Bokor, Jeffrey; Naulleau, Patrick

    2003-05-06

    An improved phase-shifting point diffraction interferometer can measure both distortion and wavefront aberration. In the preferred embodiment, the interferometer employs an object-plane pinhole array comprising a plurality of object pinholes located between the test optic and the source of electromagnetic radiation and an image-plane mask array that is positioned in the image plane of the test optic. The image-plane mask array comprises a plurality of test windows and corresponding reference pinholes, wherein the positions of the plurality of pinholes in the object-plane pinhole array register with those of the plurality of test windows in image-plane mask array. Electromagnetic radiation that is directed into a first pinhole of object-plane pinhole array thereby creating a first corresponding test beam image on the image-plane mask array. Where distortion is relatively small, it can be directly measured interferometrically by measuring the separation distance between and the orientation of the test beam and reference-beam pinhole and repeating this process for at least one other pinhole of the plurality of pinholes of the object-plane pinhole array. Where the distortion is relative large, it can be measured by using interferometry to direct the stage motion, of a stage supporting the image-plane mask array, and then use the final stage motion as a measure of the distortion.

  16. Place specificity of monopolar and tripolar stimuli in cochlear implants: the influence of residual masking.

    PubMed

    Fielden, Claire A; Kluk, Karolina; McKay, Colette M

    2013-06-01

    This experiment investigated whether place specificity of neural activity evoked by cochlear implant stimulation is improved in tripolar compared to monopolar mode using a forward masking protocol addressing some limitations of previous methods of measurement and analysis. The amount of residual masking (masking remaining at long masker-probe delays) was also measured, and its potential influence on the specificity measures was evaluated. The masker stimulus comprised equally loud interleaved mono- or tripolar stimulation on two electrodes equidistant from a central probe electrode in an apical and basal direction, reducing the influence of off-site listening. The effect of masker-probe distance on the threshold shift of the tripolar probe was analyzed to derive a measure of place specificity. On average, tripolar maskers were more place specific than monopolar maskers, although the mean effect was small. There was no significant effect of masker level on specificity or on the differences observed between modes. The mean influence of residual masking on normalized masking functions was similar for the two modes and, therefore, did not influence the comparison of specificity between the modes. However, variability in amount of residual masking was observed between subjects, and therefore should be considered in forward masking studies that compare place specificity across subjects.

  17. Recognition of speech in noise after application of time-frequency masks: Dependence on frequency and threshold parameters

    PubMed Central

    Sinex, Donal G.

    2013-01-01

    Binary time-frequency (TF) masks can be applied to separate speech from noise. Previous studies have shown that with appropriate parameters, ideal TF masks can extract highly intelligible speech even at very low speech-to-noise ratios (SNRs). Two psychophysical experiments provided additional information about the dependence of intelligibility on the frequency resolution and threshold criteria that define the ideal TF mask. Listeners identified AzBio Sentences in noise, before and after application of TF masks. Masks generated with 8 or 16 frequency bands per octave supported nearly-perfect identification. Word recognition accuracy was slightly lower and more variable with 4 bands per octave. When TF masks were generated with a local threshold criterion of 0 dB SNR, the mean speech reception threshold was −9.5 dB SNR, compared to −5.7 dB for unprocessed sentences in noise. Speech reception thresholds decreased by about 1 dB per dB of additional decrease in the local threshold criterion. Information reported here about the dependence of speech intelligibility on frequency and level parameters has relevance for the development of non-ideal TF masks for clinical applications such as speech processing for hearing aids. PMID:23556604

  18. Masking in three pinnipeds: underwater, low-frequency critical ratios.

    PubMed

    Southall, B L; Schusterman, R J; Kastak, D

    2000-09-01

    Behavioral techniques were used to determine underwater masked hearing thresholds for a northern elephant seal (Mirounga angustirostris), a harbor seal (Phoca vitulina), and a California sea lion (Zalophus californianus). Octave-band white noise maskers were centered at five test frequencies ranging from 200 to 2500 Hz; a slightly wider noise band was used for testing at 100 Hz. Critical ratios were calculated at one masking noise level for each test frequency. Above 200 Hz, critical ratios increased with frequency. This pattern is similar to that observed in most animals tested, and indicates that these pinnipeds lack specializations for detecting low-frequency tonal sounds in noise. However, the individual pinnipeds in this study, particularly the northern elephant seal, detected signals at relatively low signal-to-noise ratios. These results provide a means of estimating zones of auditory masking for pinnipeds exposed to anthropogenic noise sources.

  19. An investigation into the efficiency of disposable face masks.

    PubMed Central

    Rogers, K B

    1980-01-01

    Disposable face masks used in hospitals have been assessed for the protection afforded the patient and the wearer by challenges of simulated natural conditions of stress. Operating theatre masks made of synthetic materials allow the wearer to breathe through the masks, and these have been shown to protect the patient well but the wearer slightly less. Cheaper paper masks are worn for ward duties, and of these only the Promask protected in area in front of the wearer: air does not pass through this mask, expired air is prevented from passing forward, and the wearer breathes unfiltered air. All the other paper masks tested allowed many bacteria-laden particles to pass through them. PMID:7440756

  20. [Face protective patches do not reduce facial pressure ulcers in a simulated model of non-invasive ventilation].

    PubMed

    Riquelme M, Hugo; Wood V, David; Martínez F, Santiago; Carmona M, Fernando; Peña V, Axel; Wegner A, Adriana

    2017-06-01

    Noninvasive ventilation (NIV) frequently involves the development of facial pressure ulcers (FPU). Its prevention considers the empirical use of protective patches between skin and mask, in order to reduce the pressure exerted by it. To evaluate the effect of protective patches on the pressure exerted by the facial mask, and its impact on the programmed ventilatory parameters. Bilevel NIV simulated model using full face mask in phantom with a physiological airway (ALS PRO +) in supine position. Forehead, chin and cheekbones pressure were measured using 3 types of standard protective patches versus a control group using pressure sensors (Interlinks Electronics®). The values obtained with the protective patches-mask model were evaluated in the programmed variables maximum inspiratory flow (MIF)), expired tidal volume (Vte) and positive inspiratory pressure (IPAP), with Trilogy 100 ventilator, Respironics®. The programming and recording of the variables was carried out in 8 opportunities in each group by independent operators. There was no decrease in facial pressure with any of the protective patches compared to the control group. Moltopren increased facial pressure at all support points (p < 0.001), increased leakage, it decreased MIF, Vte and IPAP (p < 0.001). Hydrocolloid patches increased facial pressure only in the left cheekbone, increased leakage and decreased MIF. Polyurethane patches did not produce changes in facial pressure or ventilatory variables. The use of protective patches of moltopren, hydrocolloid and polyurethane transparent did not contribute to the decrease of the facial pressure. A deleterious effect of the moltopren and hydrocolloid patches was observed on the administration of ventilatory variables, concluding that the non-use of the protective patches allowed a better administration of the programmed parameters.

  1. The effects of fixed and removable face masks on maxillary deficiencies in growing patients.

    PubMed

    Jamilian, Abdolreza; Showkatbakhsh, Rahman; Taban, Tannaz

    2012-01-01

    To compare the effects of two different types of face masks in the treatment of Class III malocclusions with maxillary deficiency in growing patients. Forty-three patients (21 boys and 22 girls) with maxillary deficiencies were selected. Twenty-one patients (10 boys and 11 girls) with a mean age of 8.9 ± 1.4 years were treated with maxillary removable appliances and face masks. Twenty-two patients (10 boys and 12 girls) with a mean age of 9.3 ± 1.2 years were treated with maxillary fixed appliances and face masks. Lateral cephalograms obtained at the beginning and end of the study were analyzed. Paired t tests and Wilcoxon tests showed that SNA and ANB significantly increased in both groups. The Mann-Whitney test showed that there were no statistically significant differences between the two groups except for U1-SN, which increased by 6.2 ± 7.1 degrees in the removable face mask group and 11.1 ± 6.9 degrees in the fixed face mask group (P < .02). Both treatment modalities were successful in moving the maxilla forward. However, the maxillary incisors had more labial inclination in the fixed appliance group.

  2. Evaluation of the Sierra, hanging, quick-don, crew, pressure-breathing, oxygen mask.

    DOT National Transportation Integrated Search

    1966-06-01

    A new design, hanging, quick-don crew pressure breathing oxygen mask applicable to jet-transport operations was tested and evaluated in three phases, consisting of (1) exposing five masked subjects to a stepwise altitude-chamber flight profile with a...

  3. A face versus non-face context influences amygdala responses to masked fearful eye whites.

    PubMed

    Kim, M Justin; Solomon, Kimberly M; Neta, Maital; Davis, F Caroline; Oler, Jonathan A; Mazzulla, Emily C; Whalen, Paul J

    2016-12-01

    The structure of the mask stimulus is crucial in backward masking studies and we recently demonstrated such an effect when masking faces. Specifically, we showed that activity of the amygdala is increased to fearful facial expressions masked with neutral faces and decreased to fearful expressions masked with a pattern mask-but critically both masked conditions discriminated fearful expressions from happy expressions. Given this finding, we sought to test whether masked fearful eye whites would produce a similar profile of amygdala response in a face vs non-face context. During functional magnetic resonance imaging scanning sessions, 30 participants viewed fearful or happy eye whites masked with either neutral faces or pattern images. Results indicated amygdala activity was increased to fearful vs happy eye whites in the face mask condition, but decreased to fearful vs happy eye whites in the pattern mask condition-effectively replicating and expanding our previous report. Our data support the idea that the amygdala is responsive to fearful eye whites, but that the nature of this activity observed in a backward masking design depends on the mask stimulus. © The Author (2016). Published by Oxford University Press.

  4. A novel anti-influenza copper oxide containing respiratory face mask.

    PubMed

    Borkow, Gadi; Zhou, Steve S; Page, Tom; Gabbay, Jeffrey

    2010-06-25

    Protective respiratory face masks protect the nose and mouth of the wearer from vapor drops carrying viruses or other infectious pathogens. However, incorrect use and disposal may actually increase the risk of pathogen transmission, rather than reduce it, especially when masks are used by non-professionals such as the lay public. Copper oxide displays potent antiviral properties. A platform technology has been developed that permanently introduces copper oxide into polymeric materials, conferring them with potent biocidal properties. We demonstrate that impregnation of copper oxide into respiratory protective face masks endows them with potent biocidal properties in addition to their inherent filtration properties. Both control and copper oxide impregnated masks filtered above 99.85% of aerosolized viruses when challenged with 5.66+/-0.51 and 6.17+/-0.37 log(10)TCID(50) of human influenza A virus (H1N1) and avian influenza virus (H9N2), respectively, under simulated breathing conditions (28.3 L/min). Importantly, no infectious human influenza A viral titers were recovered from the copper oxide containing masks within 30 minutes (< or = 0.88 log(10)TCID(50)), while 4.67+/-1.35 log(10)TCID(50) were recovered from the control masks. Similarly, the infectious avian influenza titers recovered from the copper oxide containing masks were < or = 0.97+/-0.01 log(10)TCID(50) and from the control masks 5.03+/-0.54 log(10)TCID(50). The copper oxide containing masks successfully passed Bacterial Filtration Efficacy, Differential Pressure, Latex Particle Challenge, and Resistance to Penetration by Synthetic Blood tests designed to test the filtration properties of face masks in accordance with the European EN 14683:2005 and NIOSH N95 standards. Impregnation of copper oxide into respiratory protective face masks endows them with potent anti-influenza biocidal properties without altering their physical barrier properties. The use of biocidal masks may significantly reduce the risk of hand or environmental contamination, and thereby subsequent infection, due to improper handling and disposal of the masks.

  5. X ray reflection masks: Manufacturing, characterization and first tests

    NASA Astrophysics Data System (ADS)

    Rahn, Stephen

    1992-09-01

    SXPL (Soft X-ray Projection Lithography) multilayer mirrors are characterized, laterally structured and then used as reflection masks in a projecting lithography procedure. Mo/Si-multilayer mirrors with a 2d in the region of 14 nm were characterized by Cu-k(alpha) grazing incidence as well as soft X-ray normal incidence reflectivity measurements. The multilayer mirrors were patterned by reactive ion etching with CF4 using a photoresist as etch mask, thus producing X-ray reflection masks. The masks were tested at the synchrotron radiation laboratory of the electron accelerator ELSA. A double crystal X-ray monochromator was modified so as to allow about 0.5 sq cm of the reflection mask to be illuminated by white synchrotron radiation. The reflected patterns were projected (with an energy of 100 eV) onto a resist and structure sizes down to 8 micrometers were nicely reproduced. Smaller structures were distorted by Fresnel-diffraction. The theoretically calculated diffraction images agree very well with the observed images.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lemaire, H.; Barat, E.; Carrel, F.

    In this work, we tested Maximum likelihood expectation-maximization (MLEM) algorithms optimized for gamma imaging applications on two recent coded mask gamma cameras. We respectively took advantage of the characteristics of the GAMPIX and Caliste HD-based gamma cameras: noise reduction thanks to mask/anti-mask procedure but limited energy resolution for GAMPIX, high energy resolution for Caliste HD. One of our short-term perspectives is the test of MAPEM algorithms integrating specific prior values for the data to reconstruct adapted to the gamma imaging topic. (authors)

  7. Performance Comparisons of Jet and Mesh Nebulizers Using Different Interfaces in Simulated Spontaneously Breathing Adults and Children.

    PubMed

    Ari, Arzu; de Andrade, Armele Dornelas; Sheard, Meryl; AlHamad, Bshayer; Fink, James B

    2015-08-01

    Different types of nebulizers and interfaces are used for the treatment of adults and children with pulmonary diseases. The purpose of this study was to determine the efficiency of a mesh nebulizer (MN) with a proprietary adapter and a jet nebulizer (JN) under different configurations in adult and pediatric models of spontaneous breathing. We hypothesize that delivery efficiency of JN and MN will differ depending on the interface used during aerosol therapy in simulated spontaneously breathing adult and pediatric models. While we expect that aerosol delivery with JN will be less efficient than MN, we also hypothesize that lung deposition obtained with the adult lung model will be more than that with the pediatric lung model in all conditions tested in this study. A lung model using a teaching manikin connected to a sinusoidal pump via a collecting filter at the level of the bronchi simulating a spontaneously breathing adult (Vt 500 mL, RR 15 bpm, I:E ratio 1:2) or pediatric patient (Vt 150 mL, RR 25 bpm, I:E ratio 1:2). Albuterol sulfate (2.5 mg/3 mL) was aerosolized with JN (Mistymax 10, Airlife) or MN (Aerogen Solo(®), Aerogen) with the Adapter (Aerogen Solo(®) Adapter, Aerogen Ltd, Galway, Ireland) using mouthpiece, aerosol mask, and valved-mask in adults and the dragon mask, aerosol mask, and valved-mask in pediatrics (n=3). The Adapter, specifically designed for MN, was attached to all the interfaces used in this study with supplemental oxygen of 2 lpm, and in addition, the MP was tested with no additional flow in the adult model. The JN was driven with 10 lpm based on the manufacturer's label. Drug was eluted from the filter and analyzed via spectrophotometry. Descriptive statistics, dependent t-test and one-way analysis of variance were used for data analysis. Significant level was set at 0.05. In adults, delivery efficiency of JN with the valved mask was significantly greater than that with the aerosol mask (p=0.01). Aerosol delivery of JN with the mouthpiece was not statistically significant from the valved mask (p=0.123) and the aerosol mask (p=0.193). Drug delivery with MN with mouthpiece (15.42±1.4%) and valved-mask (15.15±1.1%) was greater than the open aerosol mask (7.54±0.39%; p=0.0001) in the adult lung model. With no flow mouthpiece delivery increased>2 fold (34.9±3.1%; p=.0001) compared to use of 2 lpm of flow. Using the JN with the pediatric model deposition with valved-mask (5.3±0.8%), dragon mask (4.7±0.9%), and aerosol mask (4.1±0.3%) were similar (p>0.05); while drug delivery with MN via valved-mask (11.1±0.7%) was greater than the dragon mask (6.44±0.3%; p=0.002) and aerosol mask (4.6±0.4%; p=0.002), and the dragon mask was more efficient than the open aerosol mask (p=0.009) CONCLUSION: The type of nebulizer and interface used for aerosol therapy affects delivery efficiency in these simulated spontaneously breathing adult and pediatric models. Drug delivery was greatest with the valved-mouthpiece and mask with JN and MN, while the standard aerosol mask was least efficient in these simulated spontaneously breathing adult and pediatric lung models. Delivery efficiency of JN was less than MN in all conditions tested in this study except in the aerosol mask. Lung deposition obtained with the adult lung model was more than that with the pediatric lung model.

  8. High-power modular LED-based illumination systems for mask-aligner lithography.

    PubMed

    Bernasconi, Johana; Scharf, Toralf; Vogler, Uwe; Herzig, Hans Peter

    2018-04-30

    Mask-aligner lithography is traditionally performed using mercury arc lamps with wavelengths ranging from 250 nm to 600 nm with intensity peaks at the i, g and h lines. Since mercury arc lamps present several disadvantages, it is of interest to replace them with high power light emitting diodes (LEDs), which recently appeared on the market at those wavelengths. In this contribution, we present a prototype of an LED-based mask-aligner illumination. An optical characterization is made and the prototype is tested in a mask-aligner. Very good performances are demonstrated. The measured uniformity in the mask plane is 2.59 ± 0.24 % which is within the uniformity of the standard lamp. Print tests show resolution of 1 micron in contact printing and of 3 microns in proximity printing with a proximity gap of 30 microns.

  9. Optical proximity correction for anamorphic extreme ultraviolet lithography

    NASA Astrophysics Data System (ADS)

    Clifford, Chris; Lam, Michael; Raghunathan, Ananthan; Jiang, Fan; Fenger, Germain; Adam, Kostas

    2017-10-01

    The change from isomorphic to anamorphic optics in high numerical aperture extreme ultraviolet scanners necessitates changes to the mask data preparation flow. The required changes for each step in the mask tape out process are discussed, with a focus on optical proximity correction (OPC). When necessary, solutions to new problems are demonstrated and verified by rigorous simulation. Additions to the OPC model include accounting for anamorphic effects in the optics, mask electromagnetics, and mask manufacturing. The correction algorithm is updated to include awareness of anamorphic mask geometry for mask rule checking. OPC verification through process window conditions is enhanced to test different wafer scale mask error ranges in the horizontal and vertical directions. This work will show that existing models and methods can be updated to support anamorphic optics without major changes. Also, the larger mask size in the Y direction can result in better model accuracy, easier OPC convergence, and designs that are more tolerant to mask errors.

  10. Effectiveness of Placebo Therapy for Maintaining Masking in a Clinical Trial of Vergence/Accommodative Therapy

    PubMed Central

    Kulp, Marjean; Mitchell, G. Lynn; Borsting, Eric; Scheiman, Mitchell; Cotter, Susan; Rouse, Michael; Tamkins, Susanna; Mohney, Brian G.; Toole, Andrew; Reuter, Kathleen

    2009-01-01

    Purpose To evaluate the effectiveness of the Convergence Insufficiency Treatment Trial (CITT) placebo therapy program in maintaining masking of patients randomized to the office-based treatment arms, determine whether demographic variables affect masking, and determine whether perception of assigned treatment group was associated with treatment outcome or adherence to treatment. Methods Patients (n = 221, ages, 9–17 years) were randomized to one of four treatment groups, two of which were office-based and masked to treatment (n = 114). The placebo therapy program was designed to appear to be real vergence/accommodative therapy, without stimulating vergence, accommodation, or fine saccades (beyond levels of daily visual activities). After treatment, patients in the office-based groups were asked whether they thought they had received real or placebo therapy and how confident they were in their answers. Results Ninety-three percent of patients assigned to real therapy and 85% assigned to placebo therapy thought they were in the real therapy group (P = 0.17). No significant differences were found between the two groups in adherence to the therapy (P ≥ 0.22 for all comparisons). The percentage of patients who thought they were assigned to real therapy did not differ by age, sex, race, or ethnicity (P > 0.30 for all comparisons). No association was found between patients' perception of group assignment and symptoms or signs at outcome (P ≥ 0.38 for all comparisons). Conclusions The CITT placebo therapy program was effective in maintaining patient masking in this study and therefore may have potential for use in future clinical trials using vergence/accommodative therapy. Masking was not affected by demographic variables. Perception of group assignment was not related to symptoms or signs at outcome (ClinicalTrials.gov number, NCT00338611). PMID:19151384

  11. Accuracy and performance of 3D mask models in optical projection lithography

    NASA Astrophysics Data System (ADS)

    Agudelo, Viviana; Evanschitzky, Peter; Erdmann, Andreas; Fühner, Tim; Shao, Feng; Limmer, Steffen; Fey, Dietmar

    2011-04-01

    Different mask models have been compared: rigorous electromagnetic field (EMF) modeling, rigorous EMF modeling with decomposition techniques and the thin mask approach (Kirchhoff approach) to simulate optical diffraction from different mask patterns in projection systems for lithography. In addition, each rigorous model was tested for two different formulations for partially coherent imaging: The Hopkins assumption and rigorous simulation of mask diffraction orders for multiple illumination angles. The aim of this work is to closely approximate results of the rigorous EMF method by the thin mask model enhanced with pupil filtering techniques. The validity of this approach for different feature sizes, shapes and illumination conditions is investigated.

  12. Performance of ICU ventilators during noninvasive ventilation with large leaks in a total face mask: a bench study* **

    PubMed Central

    Nakamura, Maria Aparecida Miyuki; Costa, Eduardo Leite Vieira; Carvalho, Carlos Roberto Ribeiro; Tucci, Mauro Roberto

    2014-01-01

    Objective: Discomfort and noncompliance with noninvasive ventilation (NIV) interfaces are obstacles to NIV success. Total face masks (TFMs) are considered to be a very comfortable NIV interface. However, due to their large internal volume and consequent increased CO2 rebreathing, their orifices allow proximal leaks to enhance CO2 elimination. The ventilators used in the ICU might not adequately compensate for such leakage. In this study, we attempted to determine whether ICU ventilators in NIV mode are suitable for use with a leaky TFM. Methods: This was a bench study carried out in a university research laboratory. Eight ICU ventilators equipped with NIV mode and one NIV ventilator were connected to a TFM with major leaks. All were tested at two positive end-expiratory pressure (PEEP) levels and three pressure support levels. The variables analyzed were ventilation trigger, cycling off, total leak, and pressurization. Results: Of the eight ICU ventilators tested, four did not work (autotriggering or inappropriate turning off due to misdetection of disconnection); three worked with some problems (low PEEP or high cycling delay); and one worked properly. Conclusions: The majority of the ICU ventilators tested were not suitable for NIV with a leaky TFM. PMID:25029653

  13. Masking Treatment and its Effect on Tinnitus Parameters.

    PubMed

    Aytac, Ismail; Baysal, Elif; Gulsen, Secaattin; Tumuklu, Koray; Durucu, Cengiz; Mumbuc, Lütfi Semih; Kanlikama, MUzaffer

    2017-12-01

    Tinnitus is described as the perception of sound without any external acoustic stimulation. Any pathology of auditory pathways or any system of the human body may result with tinnitus. The pathophysiology of tinnitus accompanying the disorders of auditory system is not fully understood and there is not any particular effective treatment method has been specified. Tinnitus masking therapy has been reported as an effective treatment modality in the treatment of tinnitus. In this study, the results of tinnitus masking treatment on the parameters were evaluated prospectively. Patients with normal physical examination was enrolled in the study. Blood tests (complete blood count, biochemical analysis of lipid profile, and thyroid hormones), pure tone audiometry, tympanometric measurement of the middle ear pressure and stapedial reflexes were performed, Sixty six patients with normal results of blood tests and normal hearing thresholds with type A tympanogram were included. Tinnitus sufferers questionnaires (socio-demographics, clinical information, Tinnitus Handicap Inventory (THI), Beck Depression Inventory (BDI) was filled, audiological tests were performed, tinnitus parameters (frequency, intensity, minimal masking levels, residual inhibition) were measured. After four weeks of the treatment the questionnaires were repeated. Masking treatment for tinnitus patients resulted with significant decrease in Tinnitus Handicap Inventory and VAS scores. After four weeks of the masking treatment the questionnaire was repeated. Twenty patients did not respond to treatment. Masking therapy is one of the most effective methods of treatment for tinnitus patients. Masking therapy, that is not invasive and cost-effective has an important place in the treatment of tinnitus. Especially in a short time provides a significant reduction in tinnitus parameters.

  14. The objective evaluation of aircrew protective breathing equipment : V., mask/goggles combinations for female crewmembers.

    DOT National Transportation Integrated Search

    1983-07-01

    A study was conducted to determine the degree of respiratory and visual protection given to the female crewmember by various crew oxygen mask/goggle combinations. The acceptance criteria for the mask/goggle combinations were for 10 of 12 test subject...

  15. Smelling Anxiety Chemosignals Impairs Clinical Performance of Dental Students.

    PubMed

    Singh, Preet Bano; Young, Alix; Lind, Synnøve; Leegaard, Marie Cathinka; Capuozzo, Alessandra; Parma, Valentina

    2018-05-15

    Despite the fact that human body odors can transfer anxiety-related signals, the impact of such signals in real-life situations is scant. In this study, the effects of anxiety chemosignals on the performance of dental students operating on simulation units, wearing t-shirts imbued with human sweat and masked with eugenol were tested. Twenty-four 4th year dental students (17F) donated their body odors in two sessions (Anxiety and Rest). Twenty-four normosmic, sex- and age-matched test subjects who were3rd year dental students performed three dental procedures while smelling masked anxiety body odors, masked rest body odors or masker alone. The intensity and pleasantness ratings showed that the test subjects could not report perceptual differences between the odor conditions. When exposed to masked anxiety body odors the test subject's dental performance was significantly worse than when they were exposed to masked rest body odors and masker alone, indicating that their performance was modulated by exposure to the emotional tone of the odor. These findings call for a careful evaluation of the anxiety-inducing effects of body odors in performance-related tasks and provide the first ecological evaluation of human anxiety chemosignal communication.

  16. Contralateral Masking in Bilateral Cochlear Implant Patients: A Model of Medial Olivocochlear Function Loss

    PubMed Central

    Aronoff, Justin M.; Padilla, Monica; Fu, Qian-Jie; Landsberger, David M.

    2015-01-01

    Contralateral masking is the phenomenon where a masker presented to one ear affects the ability to detect a signal in the opposite ear. For normal hearing listeners, contralateral masking results in masking patterns that are both sharper and dramatically smaller in magnitude than ipsilateral masking. The goal of this study was to investigate whether medial olivocochlear (MOC) efferents are needed for the sharpness and relatively small magnitude of the contralateral masking function. To do this, bilateral cochlear implant patients were tested because, by directly stimulating the auditory nerve, cochlear implants circumvent the effects of the MOC efferents. The results indicated that, as with normal hearing listeners, the contralateral masking function was sharper than the ipsilateral masking function. However, although there was a reduction in the magnitude of the contralateral masking function compared to the ipsilateral masking function, it was relatively modest. This is in sharp contrast to the results of normal hearing listeners where the magnitude of the contralateral masking function is greatly reduced. These results suggest that MOC function may not play a large role in the sharpness of the contralateral masking function but may play a considerable role in the magnitude of the contralateral masking function. PMID:25798581

  17. Type of mask may impact on continuous positive airway pressure adherence in apneic patients.

    PubMed

    Borel, Jean Christian; Tamisier, Renaud; Dias-Domingos, Sonia; Sapene, Marc; Martin, Francis; Stach, Bruno; Grillet, Yves; Muir, Jean François; Levy, Patrick; Series, Frederic; Pepin, Jean-Louis

    2013-01-01

    In obstructive sleep apnea patients (OSA), continuous positive airway pressure (CPAP) adherence is crucial to improve symptoms and cardiometabolic outcomes. The choice of mask may influence CPAP adherence but this issue has never been addressed properly. To evaluate the impact of nasal pillows, nasal and oronasal masks on CPAP adherence in a cohort of OSA. Newly CPAP treated OSA participating in "Observatoire Sommeil de la Fédération de Pneumologie", a French national prospective cohort, were included between March 2009 and December 2011. Anthropometric data, medical history, OSA severity, sleepiness, depressive status, treatment modalities (auto-CPAP versus fixed pressure, pressure level, interface type, use of humidifiers) and CPAP-related side effects were included in multivariate analysis to determine independent variables associated with CPAP adherence. 2311 OSA (age = 57(12) years, apnea+hypopnea index = 41(21)/h, 29% female) were included. Nasal masks, oronasal masks and nasal pillows were used by 62.4, 26.2 and 11.4% of the patients, respectively. In univariate analysis, oronasal masks and nasal pillows were associated with higher risk of CPAP non-adherence. CPAP non-adherence was also associated with younger age, female gender, mild OSA, gastroesophageal reflux, depression status, low effective pressure and CPAP-related side effects. In multivariate analysis, CPAP non-adherence was associated with the use of oronasal masks (OR = 2.0; 95%CI = 1.6; 2.5), depression, low effective pressure, and side effects. As oronasal masks negatively impact on CPAP adherence, a nasal mask should be preferred as the first option. Patients on oronasal masks should be carefully followed.

  18. Profiles of Patients Demonstrating Abnormal Masking Level Difference Response.

    ERIC Educational Resources Information Center

    Battin, R. Ray; Waryas, Paul A.

    1985-01-01

    Profiles of three persons (9-11 years old) with extremely reduced masking level difference results (scores which measure binaural release from masking) are reported. It is suggested that tests of the MLD appear to be a useful adjunct of an evaluation battery for patients with presumed auditory perceptual problems. (CL)

  19. Filter penetration and breathing resistance evaluation of respirators and dust masks.

    PubMed

    Ramirez, Joel; O'Shaughnessy, Patrick

    2017-02-01

    The primary objective of this study was to compare the filter performance of a representative selection of uncertified dust masks relative to the filter performance of a set of NIOSH-approved N95 filtering face-piece respirators (FFRs). Five different models of commercially available dust masks were selected for this study. Filter penetration of new dust masks was evaluated against a sodium chloride aerosol. Breathing resistance (BR) of new dust masks and FFRs was then measured for 120 min while challenging the dust masks and FFRs with Arizona road dust (ARD) at 25°C and 30% relative humidity. Results demonstrated that a wide range of maximum filter penetration was observed among the dust masks tested in this study (3-75% at the most penetrating particle size (p < 0.001). The breathing resistances of the unused FFRs and dust masks did not vary greatly (8-13 mm H 2 O) but were significantly different (p < 0.001). After dust loading there was a significant difference between the BR caused by the ARD dust layer on each FFR and dust mask. Microscopic analysis of the external layer of each dust mask and FFR suggests that different collection media in the external layer influences the development of the dust layer and therefore affects the increase in BR differently between the tested models. Two of the dust masks had penetration values < 5% and quality factors (0.26 and 0.33) comparable to those obtained for the two FFRs (0.23 and 0.31). However, the remaining three dust masks, those with penetration > 15%, had quality factors ranging between 0.04-0.15 primarily because their initial BR remained relatively high. These results indicate that some dust masks analysed during this research did not have an expected very low BR to compensate for their high penetration.

  20. Musicians and non-musicians are equally adept at perceiving masked speech

    PubMed Central

    Boebinger, Dana; Evans, Samuel; Scott, Sophie K.; Rosen, Stuart; Lima, César F.; Manly, Tom

    2015-01-01

    There is much interest in the idea that musicians perform better than non-musicians in understanding speech in background noise. Research in this area has often used energetic maskers, which have their effects primarily at the auditory periphery. However, masking interference can also occur at more central auditory levels, known as informational masking. This experiment extends existing research by using multiple maskers that vary in their informational content and similarity to speech, in order to examine differences in perception of masked speech between trained musicians (n = 25) and non-musicians (n = 25). Although musicians outperformed non-musicians on a measure of frequency discrimination, they showed no advantage in perceiving masked speech. Further analysis revealed that nonverbal IQ, rather than musicianship, significantly predicted speech reception thresholds in noise. The results strongly suggest that the contribution of general cognitive abilities needs to be taken into account in any investigations of individual variability for perceiving speech in noise. PMID:25618067

  1. Variability-aware double-patterning layout optimization for analog circuits

    NASA Astrophysics Data System (ADS)

    Li, Yongfu; Perez, Valerio; Tripathi, Vikas; Lee, Zhao Chuan; Tseng, I.-Lun; Ong, Jonathan Yoong Seang

    2018-03-01

    The semiconductor industry has adopted multi-patterning techniques to manage the delay in the extreme ultraviolet lithography technology. During the design process of double-patterning lithography layout masks, two polygons are assigned to different masks if their spacing is less than the minimum printable spacing. With these additional design constraints, it is very difficult to find experienced layout-design engineers who have a good understanding of the circuit to manually optimize the mask layers in order to minimize color-induced circuit variations. In this work, we investigate the impact of double-patterning lithography on analog circuits and provide quantitative analysis for our designers to select the optimal mask to minimize the circuit's mismatch. To overcome the problem and improve the turn-around time, we proposed our smart "anchoring" placement technique to optimize mask decomposition for analog circuits. We have developed a software prototype that is capable of providing anchoring markers in the layout, allowing industry standard tools to perform automated color decomposition process.

  2. Manipulating perceptual parameters in a continuous performance task.

    PubMed

    Shalev, Nir; Humphreys, Glyn; Demeyere, Nele

    2018-02-01

    Sustained attention (SA) is among the most studied faculties of human cognition, and thought to be crucial for many aspects of behavior. Measuring SA often relies on performance on a continuous, low-demanding task. Such continuous performance tasks (CPTs) have many variations, and sustained attention is typically estimated based on variability in reaction times. While relying on reaction times may be useful in some cases, it can pose a challenge when working with clinical populations. To increase interpersonal variability in task parameters that do not rely on speed, researchers have increased demands for memory and response inhibition. These approaches, however, may be confounded when used to assess populations that suffer from multiple cognitive deficits. In the current study, we propose a new approach for increasing task variability by increasing the attentional demands. In order to do so, we created a new variation of a CPT - a masked version, where inattention is more likely to cause misidentifying a target. After establishing that masking indeed decreases target detection, we further investigated which task parameter may influence response biases. To do so, we contrasted two versions of the CPT with different target/distractor ratio. We then established how perceptual parameters can be controlled independently in a CPT. Following the experimental manipulations, we tested the MCCPT with aging controls and chronic stroke patients to assure the task can be used with target populations. The results confirm the MCCPT as a task providing high sensitivity without relying on reaction speed, and feasible for patients.

  3. Simulation based mask defect repair verification and disposition

    NASA Astrophysics Data System (ADS)

    Guo, Eric; Zhao, Shirley; Zhang, Skin; Qian, Sandy; Cheng, Guojie; Vikram, Abhishek; Li, Ling; Chen, Ye; Hsiang, Chingyun; Zhang, Gary; Su, Bo

    2009-10-01

    As the industry moves towards sub-65nm technology nodes, the mask inspection, with increased sensitivity and shrinking critical defect size, catches more and more nuisance and false defects. Increased defect counts pose great challenges in the post inspection defect classification and disposition: which defect is real defect, and among the real defects, which defect should be repaired and how to verify the post-repair defects. In this paper, we address the challenges in mask defect verification and disposition, in particular, in post repair defect verification by an efficient methodology, using SEM mask defect images, and optical inspection mask defects images (only for verification of phase and transmission related defects). We will demonstrate the flow using programmed mask defects in sub-65nm technology node design. In total 20 types of defects were designed including defects found in typical real circuit environments with 30 different sizes designed for each type. The SEM image was taken for each programmed defect after the test mask was made. Selected defects were repaired and SEM images from the test mask were taken again. Wafers were printed with the test mask before and after repair as defect printability references. A software tool SMDD-Simulation based Mask Defect Disposition-has been used in this study. The software is used to extract edges from the mask SEM images and convert them into polygons to save in GDSII format. Then, the converted polygons from the SEM images were filled with the correct tone to form mask patterns and were merged back into the original GDSII design file. This merge is for the purpose of contour simulation-since normally the SEM images cover only small area (~1 μm) and accurate simulation requires including larger area of optical proximity effect. With lithography process model, the resist contour of area of interest (AOI-the area surrounding a mask defect) can be simulated. If such complicated model is not available, a simple optical model can be used to get simulated aerial image intensity in the AOI. With built-in contour analysis functions, the SMDD software can easily compare the contour (or intensity) differences between defect pattern and normal pattern. With user provided judging criteria, this software can be easily disposition the defect based on contour comparison. In addition, process sensitivity properties, like MEEF and NILS, can be readily obtained in the AOI with a lithography model, which will make mask defect disposition criteria more intelligent.

  4. The threshold signal:noise ratio in the perception of fragmented figures.

    PubMed

    Merkul'ev, A V; Pronin, S V; Semenov, L A; Foreman, N; Chikhman, V N; Shelepin, Yu E

    2006-01-01

    Perception thresholds were measured for fragmented outline figures (the Gollin test). A new approach to the question of the perception of incomplete images was developed. In this approach, figure fragmentation consisted of masking with multiplicative texture-like noise--this interference was termed "invisible" masking. The first series of studies established that the "similarity" between the amplitude-frequency spectra of test figures and "invisible" masks, expressed as a linear correlation coefficient, had significant effects on the recognition thresholds of these figures. The second series of experiments showed that progressing formation of the figures was accompanied by increases in the correlation between their spatial-frequency characteristics and the corresponding characteristics of the incomplete figure, while the correlation with the "invisible" mask decreased. It is suggested that the ratio of the correlation coefficients, characterizing the "similarity" of the fragmented figure with the intact figure and the "invisible" mask, corresponds to the signal:noise ratio. The psychophysical recognition threshold for figures for naive subjects not familiar with the test image alphabet was reached after the particular level of fragmentation at which this ratio was unity.

  5. Evoked-potential recovery during double click stimulation in a beluga whale: implications for biosonar gain control.

    PubMed

    Supin, Alexander Ya; Popov, Vladimir V

    2015-05-01

    Auditory evoked potentials (AEPs) were recorded in a beluga whale Delphinapterus leucas using a double-pulse stimulation paradigm, specifically measuring the recovery (release from masking) of the second (test) response as a function of delay after the first (conditioning) pulse at various levels of the conditioning and test stimuli. The conditioning/test stimulus level ratio influenced the recovery time (the higher the ratio, the longer the recovery). This interrelation was used to evaluate the intensity/time trade in release from forward masking. Trade was evaluated as 32.2 dB per time decade. Data were considered as simulating interactions between the transmitted pulse and echo during echolocation, assuming that a transmitted sonar pulse produces forward masking of the echo response. With increased target distance, the attenuation of the echo may be compensated by the release from masking. According to the model, the compensation results in substantial stabilization of the echo response even if the intensity/time trade of release from masking is not precisely equal to the rate of echo attenuation with distance.

  6. Utilization of a modified special-cubic design and an electronic tongue for bitterness masking formulation optimization.

    PubMed

    Li, Lianli; Naini, Venkatesh; Ahmed, Salah U

    2007-10-01

    A unique modification of simplex design was applied to an electronic tongue (E-Tongue) analysis in bitterness masking formulation optimization. Three formulation variables were evaluated in the simplex design, i.e. concentrations of two taste masking polymers, Amberlite and Carbopol, and pH of the granulating fluid. Response of the design was a bitterness distance measured using an E-Tongue by applying a principle component analysis, which represents taste masking efficiency of the formulation. The smaller the distance, the better the bitterness masking effect. Contour plots and polynomial equations of the bitterness distance response were generated as a function of formulation composition and pH. It was found that interactions between polymer and pH reduced the bitterness of the formulation, attributed to pH-dependent ionization and complexation properties of the ionic polymers, thus keeping the drug out of solution and unavailable to bitterness perception. At pH 4.9 and an Amberlite/Carbopol ratio of 1.4:1 (w/w), the optimal taste masking formulation was achieved and in agreement with human gustatory sensation study results. Therefore, adopting a modified simplex experimental design on response measured using an E-Tongue provided an efficient approach to taste masking formulation optimization using ionic binding polymers. (c) 2007 Wiley-Liss, Inc.

  7. [Recognition of visual objects under forward masking. Effects of cathegorial similarity of test and masking stimuli].

    PubMed

    Gerasimenko, N Iu; Slavutskaia, A V; Kalinin, S A; Kulikov, M A; Mikhaĭlova, E S

    2013-01-01

    In 38 healthy subjects accuracy and response time were examined during recognition of two categories of images--animals andnonliving objects--under forward masking. We revealed new data that masking effects depended of categorical similarity of target and masking stimuli. The recognition accuracy was the lowest and the response time was the most slow, when the target and masking stimuli belongs to the same category, that was combined with high dispersion of response times. The revealed effects were more clear in the task of animal recognition in comparison with the recognition of nonliving objects. We supposed that the revealed effects connected with interference between cortical representations of the target and masking stimuli and discussed our results in context of cortical interference and negative priming.

  8. Robust Skull-Stripping Segmentation Based on Irrational Mask for Magnetic Resonance Brain Images.

    PubMed

    Moldovanu, Simona; Moraru, Luminița; Biswas, Anjan

    2015-12-01

    This paper proposes a new method for simple, efficient, and robust removal of the non-brain tissues in MR images based on an irrational mask for filtration within a binary morphological operation framework. The proposed skull-stripping segmentation is based on two irrational 3 × 3 and 5 × 5 masks, having the sum of its weights equal to the transcendental number π value provided by the Gregory-Leibniz infinite series. It allows maintaining a lower rate of useful pixel loss. The proposed method has been tested in two ways. First, it has been validated as a binary method by comparing and contrasting with Otsu's, Sauvola's, Niblack's, and Bernsen's binary methods. Secondly, its accuracy has been verified against three state-of-the-art skull-stripping methods: the graph cuts method, the method based on Chan-Vese active contour model, and the simplex mesh and histogram analysis skull stripping. The performance of the proposed method has been assessed using the Dice scores, overlap and extra fractions, and sensitivity and specificity as statistical methods. The gold standard has been provided by two neurologist experts. The proposed method has been tested and validated on 26 image series which contain 216 images from two publicly available databases: the Whole Brain Atlas and the Internet Brain Segmentation Repository that include a highly variable sample population (with reference to age, sex, healthy/diseased). The approach performs accurately on both standardized databases. The main advantage of the proposed method is its robustness and speed.

  9. Large-Scale Structure of the Molecular Gas in Taurus Revealed by High Spatial Dynamic Range Spectral Line Mapping

    NASA Technical Reports Server (NTRS)

    Goldsmith, Paul F.

    2008-01-01

    Viewgraph topics include: optical image of Taurus; dust extinction in IR has provided a new tool for probing cloud morphology; observations of the gas can contribute critical information on gas temperature, gas column density and distribution, mass, and kinematics; the Taurus molecular cloud complex; average spectra in each mask region; mas 2 data; dealing with mask 1 data; behavior of mask 1 pixels; distribution of CO column densities; conversion to H2 column density; variable CO/H2 ratio with values much less than 10(exp -4) at low N indicated by UV results; histogram of N(H2) distribution; H2 column density distribution in Taurus; cumulative distribution of mass and area; lower CO fractional abundance in mask 0 and 1 regions greatly increases mass determined in the analysis; masses determined with variable X(CO) and including diffuse regions agrees well with the found from L(CO); distribution of young stars as a function of molecular column density; star formation efficiency; star formation rate and gas depletion; and enlarged images of some of the regions with numerous young stars. Additional slides examine the origin of the Taurus molecular cloud, evolution from HI gas, kinematics as a clue to its origin, and its relationship to star formation.

  10. Adapting MODIS Dust Mask Algorithm to Suomi NPP VIIRS for Air Quality Applications

    NASA Astrophysics Data System (ADS)

    Ciren, P.; Liu, H.; Kondragunta, S.; Laszlo, I.

    2012-12-01

    Despite pollution reduction control strategies enforced by the Environmental Protection Agency (EPA), large regions of the United States are often under exceptional events such as biomass burning and dust outbreaks that lead to non-attainment of particulate matter standards. This has warranted the National Weather Service (NWS) to provide smoke and dust forecast guidance to the general public. The monitoring and forecasting of dust outbreaks relies on satellite data. Currently, Aqua/MODIS (MODerate resolution Imaging Spectrometer) and Terra/MODIS provide measurements needed to derive dust mask and Aerosol Optical Thickness (AOT) products. The newly launched Suomi NPP VIIRS (Visible/Infrared Imaging Radiometer Suite) instrument has a Suspended Matter (SM) product that indicates the presence of dust, smoke, volcanic ash, sea salt, and unknown aerosol types in a given pixel. The algorithm to identify dust is different over land and ocean but for both, the information comes from AOT retrieval algorithm. Over land, the selection of dust aerosol model in the AOT retrieval algorithm indicates the presence of dust and over ocean a fine mode fraction smaller than 20% indicates dust. Preliminary comparisons of VIIRS SM to CALIPSO Vertical Feature Mask (VFM) aerosol type product indicate that the Probability of Detection (POD) is at ~10% and the product is not mature for operational use. As an alternate approach, NESDIS dust mask algorithm developed for NWS dust forecast verification that uses MODIS deep blue, visible, and mid-IR channels using spectral differencing techniques and spatial variability tests was applied to VIIRS radiances. This algorithm relies on the spectral contrast of dust absorption at 412 and 440 nm and an increase in reflectivity at 2.13 μm when dust is present in the atmosphere compared to a clear sky. To avoid detecting bright desert surface as airborne dust, the algorithm uses the reflectances at 1.24 μm and 2.25 μm to flag bright pixels. The algorithm flags pixels that fall into the glint region so sun glint is not picked up as dust. The algorithm also has a spatial variability test that uses reflectances at 0.86 μm to screen for clouds over water. Analysis of one granule for a known dust event on May 2, 2012 shows that the agreement between VIIRS and MODIS is 82% and VIIRS and CALIPSO is 71%. The probability of detection for VIIRS when compared to MODIS and CALIPSO is 53% and 45% respectively whereas the false alarm ratio for VIIRS when compared to MODIS and CALIPSO is 20% and 37% respectively. The algorithm details, results from the test cases, and the use of the dust flag product in NWS applications will be presented.

  11. Optical proximity correction for anamorphic extreme ultraviolet lithography

    NASA Astrophysics Data System (ADS)

    Clifford, Chris; Lam, Michael; Raghunathan, Ananthan; Jiang, Fan; Fenger, Germain; Adam, Kostas

    2017-10-01

    The change from isomorphic to anamorphic optics in high numerical aperture (NA) extreme ultraviolet (EUV) scanners necessitates changes to the mask data preparation flow. The required changes for each step in the mask tape out process are discussed, with a focus on optical proximity correction (OPC). When necessary, solutions to new problems are demonstrated, and verified by rigorous simulation. Additions to the OPC model include accounting for anamorphic effects in the optics, mask electromagnetics, and mask manufacturing. The correction algorithm is updated to include awareness of anamorphic mask geometry for mask rule checking (MRC). OPC verification through process window conditions is enhanced to test different wafer scale mask error ranges in the horizontal and vertical directions. This work will show that existing models and methods can be updated to support anamorphic optics without major changes. Also, the larger mask size in the Y direction can result in better model accuracy, easier OPC convergence, and designs which are more tolerant to mask errors.

  12. Mechanisms of Masked Priming: Testing the Entry Opening Model

    ERIC Educational Resources Information Center

    Wu, Hongmei

    2012-01-01

    Since it was introduced in Forster and Davis (1984), masked priming has been widely adopted in the psycholinguistic research on visual word recognition, but there has been little consensus on its actual mechanisms, i.e. how it occurs and how it should be interpreted. This dissertation addresses two different interpretations of masked priming, one…

  13. Cognitive disorganisation in schizotypy is associated with deterioration in visual backward masking.

    PubMed

    Cappe, Céline; Herzog, Michael H; Herzig, Daniela A; Brand, Andreas; Mohr, Christine

    2012-12-30

    To understand the causes of schizophrenia, a search for stable markers (endophenotypes) is ongoing. In previous years, we have shown that the shine-through visual backward masking paradigm meets the most important characteristics of an endophenotype. Here, we tested masking performance differences between healthy students with low and high schizotypy scores as determined by the self-report O-Life questionnaire assessing schizotypy along three dimensions, i.e. positive schizotypy (unusual experiences), cognitive disorganisation, and negative schizotypy (introvertive anhedonia). Forty participants performed the shine-through backward masking task and a classical cognitive test, the Wisconsin Card Sorting Task (WCST). We found that visual backward masking was impaired for students scoring high as compared to low on the cognitive disorganisation dimension, whereas the positive and negative schizotypy dimensions showed no link to masking performance. We also found group differences for students scoring high and low on the cognitive disorganisation factor for the WCST. These findings indicate that the shine-through paradigm is sensitive to differences in schizotypy which are closely linked with the pathological expression in schizophrenia. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  14. 42 CFR 84.125 - Particulate tests; canisters containing particulate filters; minimum requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... filters; minimum requirements. 84.125 Section 84.125 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF... RESPIRATORY PROTECTIVE DEVICES Gas Masks § 84.125 Particulate tests; canisters containing particulate filters; minimum requirements. Gas mask canisters containing filters for protection against particulates (e.g...

  15. 42 CFR 84.125 - Particulate tests; canisters containing particulate filters; minimum requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... filters; minimum requirements. 84.125 Section 84.125 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF... RESPIRATORY PROTECTIVE DEVICES Gas Masks § 84.125 Particulate tests; canisters containing particulate filters; minimum requirements. Gas mask canisters containing filters for protection against particulates (e.g...

  16. 42 CFR 84.125 - Particulate tests; canisters containing particulate filters; minimum requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... filters; minimum requirements. 84.125 Section 84.125 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF... RESPIRATORY PROTECTIVE DEVICES Gas Masks § 84.125 Particulate tests; canisters containing particulate filters; minimum requirements. Gas mask canisters containing filters for protection against particulates (e.g...

  17. 42 CFR 84.125 - Particulate tests; canisters containing particulate filters; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... filters; minimum requirements. 84.125 Section 84.125 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF... RESPIRATORY PROTECTIVE DEVICES Gas Masks § 84.125 Particulate tests; canisters containing particulate filters; minimum requirements. Gas mask canisters containing filters for protection against particulates (e.g...

  18. 42 CFR 84.125 - Particulate tests; canisters containing particulate filters; minimum requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... filters; minimum requirements. 84.125 Section 84.125 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF... RESPIRATORY PROTECTIVE DEVICES Gas Masks § 84.125 Particulate tests; canisters containing particulate filters; minimum requirements. Gas mask canisters containing filters for protection against particulates (e.g...

  19. A Novel Anti-Influenza Copper Oxide Containing Respiratory Face Mask

    PubMed Central

    Borkow, Gadi; Zhou, Steve S.; Page, Tom; Gabbay, Jeffrey

    2010-01-01

    Background Protective respiratory face masks protect the nose and mouth of the wearer from vapor drops carrying viruses or other infectious pathogens. However, incorrect use and disposal may actually increase the risk of pathogen transmission, rather than reduce it, especially when masks are used by non-professionals such as the lay public. Copper oxide displays potent antiviral properties. A platform technology has been developed that permanently introduces copper oxide into polymeric materials, conferring them with potent biocidal properties. Methodology/Principal Findings We demonstrate that impregnation of copper oxide into respiratory protective face masks endows them with potent biocidal properties in addition to their inherent filtration properties. Both control and copper oxide impregnated masks filtered above 99.85% of aerosolized viruses when challenged with 5.66±0.51 and 6.17±0.37 log10TCID50 of human influenza A virus (H1N1) and avian influenza virus (H9N2), respectively, under simulated breathing conditions (28.3 L/min). Importantly, no infectious human influenza A viral titers were recovered from the copper oxide containing masks within 30 minutes (≤0.88 log10TCID50), while 4.67±1.35 log10TCID50 were recovered from the control masks. Similarly, the infectious avian influenza titers recovered from the copper oxide containing masks were ≤0.97±0.01 log10TCID50 and from the control masks 5.03±0.54 log10TCID50. The copper oxide containing masks successfully passed Bacterial Filtration Efficacy, Differential Pressure, Latex Particle Challenge, and Resistance to Penetration by Synthetic Blood tests designed to test the filtration properties of face masks in accordance with the European EN 14683:2005 and NIOSH N95 standards. Conclusions/Significance Impregnation of copper oxide into respiratory protective face masks endows them with potent anti-influenza biocidal properties without altering their physical barrier properties. The use of biocidal masks may significantly reduce the risk of hand or environmental contamination, and thereby subsequent infection, due to improper handling and disposal of the masks. PMID:20592763

  20. Nasal versus face mask for multiple-breath washout technique in preterm infants.

    PubMed

    Schulzke, S M; Deeptha, K; Sinhal, S; Baldwin, D N; Pillow, J J

    2008-09-01

    The large dead space associated with face masks might impede the accuracy and feasibility of multiple-breath washout (MBW) measurements in small infants. We asked if a low dead space nasal mask would provide measurements of resting lung volume and ventilation inhomogeneity comparable to those obtained with a face mask, when using the MBW technique. Unsedated preterm infants breathing without mechanical assistance and weighing between 1.50 and 2.49 kg were studied. Paired MBW tests with nasal and face masks were obtained using sulphur hexafluoride (SF(6)) as the tracer gas. The order of mask application was quasi-randomized. Bland-Altman method and intraclass correlation coefficient were used to analyze outcomes. Measurements were obtained in 20 infants with a mean (SD) postmenstrual age of 36 (1.4) w and a test weight of 2.0 (0.3) kg. The mean difference (95% CI) for nasal vs. face mask was -3.2 breaths/min (-6.2, -0.1 breaths/min) for respiratory rate, -1.0 ml/kg (-2.3, 0.3 ml/kg) for lung volume, 0.6 (0.1, 1.1) for lung clearance index, 0.2 (0.1, 0.3) for first to zeroeth moment ratio and 1.33 (0.6, 2.4) for second to zeroeth moment ratio. Paired measurements of lung volume showed acceptable agreement and good correlation, but there was poor agreement and poor correlation between indices of ventilation inhomogeneity obtained with the two masks. Functional dead space of the nasal mask was similar to that of the face mask despite its smaller water displacement volume. During MBW in infants below 2.5 kg body weight, a nasal mask results in comparable lung volume measurements. Indices of ventilation inhomogeneity may not be directly comparable using masks with different dead space. (c) 2008 Wiley-Liss, Inc.

  1. Redesign of an Open-System Oxygen Face Mask With Mainstream Capnometer for Children.

    PubMed

    Napolitano, Natalie; Nishisaki, Akira; Buffman, Hayley S; Leffelman, Jessica; Maltese, Matthew R; Nadkarni, Vinay M

    2017-01-01

    Partial pressure of end-tidal carbon dioxide (P ETCO 2 ) monitoring in children is important to detect apnea or hypopnea early to intervene before hypoxemia develops. Monitoring P ETCO 2 in children without a tracheal tube is challenging. To improve P ETCO 2 measurement accuracy in a commercially available mask with a mainstream CO 2 detector, we implemented design changes with deform-and-hold shaping technology and anterior-posterior adjustment of the expiratory gas flow cup. Two sizes of redesigned face masks (small for 7-20 kg, medium for 10-40 kg) were evaluated. Initial bench testing used a simulator modeling a spontaneously breathing infant and child with a natural airway. An infant/child manikin head was connected to the breathing lung simulator. A mass flow controller provided expiratory CO 2 . Mask fit was then evaluated on healthy human subjects to identify anatomical features associated with good fit, defined as square shape capnography waveform during expiration. A 3-dimensional digital scan was used to quantify anatomical features. The gaps between face mask rims and facial surface were manually measured. Bench testing revealed a P ETCO 2 difference of 3.4 ± 1.5 mm Hg between a measured P ETCO 2 by the redesigned mask and CO 2 concentration at trachea, as compared with 6.7 ± 6.2 mm Hg between P ETCO 2 measured by nasal cannula and trachea (P < .001). In the human mask fit study, 35 children (13 ± 4 kg) with the small mask and 38 (24 ± 8 kg) with the medium mask were evaluated. Capnography tracing was successfully obtained in 86% of the small and 100% of the medium masks. In children with small-size masks, the gap between the face mask rim and the child's face was not statistically different among those with good mask fit and without (1.0 ± 1.5 mm vs 1.4 ± 1.9 mm, P = .73). P ETCO 2 measurement by a redesigned open-system face mask with a mainstream CO 2 detector was accurate in the bench setting. The redesigned face mask can attain good mask fit and accurate capnography tracings in the majority of infants and children. Copyright © 2017 by Daedalus Enterprises.

  2. Individual Differences in Behavioral and Electrophysiological Measures of Binaural Processing Across the Adult Life Span.

    PubMed

    Roup, Christina M; Leigh, Elizabeth D

    2015-06-01

    The purpose of the present study was to examine individual differences in binaural processing across the adult life span. Sixty listeners (aged 23-80 years) with symmetrical hearing were tested. Binaural behavioral processing was measured by the Words-in-Noise Test, the 500-Hz masking level difference, and the Dichotic Digit Test. Electrophysiologic responses were assessed by the auditory middle latency response binaural interaction component. No correlations among binaural measures were found. Age accounted for the greatest amount of variability in speech-in-noise performance. Age was significantly correlated with the Words-in-Noise Test binaural advantage and dichotic ear advantage. Partial correlations, however, revealed that this was an effect of hearing status rather than age per se. Inspection of individual results revealed that 20% of listeners demonstrated reduced binaural performance for at least 2 of the binaural measures. The lack of significant correlations among variables suggests that each is an important measurement of binaural abilities. For some listeners, binaural processing was abnormal, reflecting a binaural processing deficit not identified by monaural audiologic tests. The inclusion of a binaural test battery in the audiologic evaluation is supported given that these listeners may benefit from alternative forms of audiologic rehabilitation.

  3. Gray scale x-ray mask

    DOEpatents

    Morales, Alfredo M [Livermore, CA; Gonzales, Marcela [Seattle, WA

    2006-03-07

    The present invention describes a method for fabricating an embossing tool or an x-ray mask tool, providing microstructures that smoothly vary in height from point-to-point in etched substrates, i.e., structure which can vary in all three dimensions. The process uses a lithographic technique to transfer an image pattern in the surface of a silicon wafer by exposing and developing the resist and then etching the silicon substrate. Importantly, the photoresist is variably exposed so that when developed some of the resist layer remains. The remaining undeveloped resist acts as an etchant barrier to the reactive plasma used to etch the silicon substrate and therefore provides the ability etch structures of variable depths.

  4. Analytical modeling and tolerance analysis of a linear variable filter for spectral order sorting.

    PubMed

    Ko, Cheng-Hao; Chang, Kuei-Ying; Huang, You-Min

    2015-02-23

    This paper proposes an innovative method to overcome the low production rate of current linear variable filter (LVF) fabrication. During the fabrication process, a commercial coater is combined with a local mask on a substrate. The proposed analytical thin film thickness model, which is based on the geometry of the commercial coater, is developed to more effectively calculate the profiles of LVFs. Thickness tolerance, LVF zone width, thin film layer structure, transmission spectrum and the effects of variations in critical parameters of the coater are analyzed. Profile measurements demonstrate the efficacy of local mask theory in the prediction of evaporation profiles with a high degree of accuracy.

  5. Type of Mask May Impact on Continuous Positive Airway Pressure Adherence in Apneic Patients

    PubMed Central

    Borel, Jean Christian; Tamisier, Renaud; Dias-Domingos, Sonia; Sapene, Marc; Martin, Francis; Stach, Bruno; Grillet, Yves; Muir, Jean François; Levy, Patrick; Series, Frederic; Pepin, Jean-Louis

    2013-01-01

    Rationale In obstructive sleep apnea patients (OSA), continuous positive airway pressure (CPAP) adherence is crucial to improve symptoms and cardiometabolic outcomes. The choice of mask may influence CPAP adherence but this issue has never been addressed properly. Objective To evaluate the impact of nasal pillows, nasal and oronasal masks on CPAP adherence in a cohort of OSA. Methods Newly CPAP treated OSA participating in “Observatoire Sommeil de la Fédération de Pneumologie”, a French national prospective cohort, were included between March 2009 and December 2011. Anthropometric data, medical history, OSA severity, sleepiness, depressive status, treatment modalities (auto-CPAP versus fixed pressure, pressure level, interface type, use of humidifiers) and CPAP-related side effects were included in multivariate analysis to determine independent variables associated with CPAP adherence. Results 2311 OSA (age = 57(12) years, apnea+hypopnea index = 41(21)/h, 29% female) were included. Nasal masks, oronasal masks and nasal pillows were used by 62.4, 26.2 and 11.4% of the patients, respectively. In univariate analysis, oronasal masks and nasal pillows were associated with higher risk of CPAP non-adherence. CPAP non-adherence was also associated with younger age, female gender, mild OSA, gastroesophageal reflux, depression status, low effective pressure and CPAP-related side effects. In multivariate analysis, CPAP non-adherence was associated with the use of oronasal masks (OR = 2.0; 95%CI = 1.6; 2.5), depression, low effective pressure, and side effects. Conclusion As oronasal masks negatively impact on CPAP adherence, a nasal mask should be preferred as the first option. Patients on oronasal masks should be carefully followed. PMID:23691209

  6. Evaluation of Visual Acuity Measurements after Autorefraction versus Manual Refraction in Eyes with and without Diabetic Macular Edema

    PubMed Central

    Sun, Jennifer K.; Qin, Haijing; Aiello, Lloyd Paul; Melia, Michele; Beck, Roy W.; Andreoli, Christopher M.; Edwards, Paul A.; Glassman, Adam R.; Pavlica, Michael R.

    2012-01-01

    Objective To compare visual acuity (VA) scores after autorefraction versus research protocol manual refraction in eyes of patients with diabetes and a wide range of VA. Methods Electronic Early Treatment Diabetic Retinopathy Study (E-ETDRS) VA Test© letter score (EVA) was measured after autorefraction (AR-EVA) and after Diabetic Retinopathy Clinical Research Network (DRCR.net) protocol manual refraction (MR-EVA). Testing order was randomized, study participants and VA examiners were masked to refraction source, and a second EVA utilizing an identical manual refraction (MR-EVAsupl) was performed to determine test-retest variability. Results In 878 eyes of 456 study participants, median MR-EVA was 74 (Snellen equivalent approximately 20/32). Spherical equivalent was often similar for manual and autorefraction (median difference: 0.00, 5th and 95th percentiles −1.75 to +1.13 Diopters). However, on average, MR-EVA results were slightly better than AR-EVA results across the entire VA range. Furthermore, variability between AR-EVA and MR-EVA was substantially greater than the test-retest variability of MR-EVA (P<0.001). Variability of differences was highly dependent on autorefractor model. Conclusions Across a wide range of VA at multiple sites using a variety of autorefractors, VA measurements tend to be worse with autorefraction than manual refraction. Differences between individual autorefractor models were identified. However, even among autorefractor models comparing most favorably to manual refraction, VA variability between autorefraction and manual refraction is higher than the test-retest variability of manual refraction. The results suggest that with current instruments, autorefraction is not an acceptable substitute for manual refraction for most clinical trials with primary outcomes dependent on best-corrected VA. PMID:22159173

  7. Effect of test exercises and mask donning on measured respirator fit.

    PubMed

    Crutchfield, C D; Fairbank, E O; Greenstein, S L

    1999-12-01

    Quantitative respirator fit test protocols are typically defined by a series of fit test exercises. A rationale for the protocols that have been developed is generally not available. There also is little information available that describes the effect or effectiveness of the fit test exercises currently specified in respiratory protection standards. This study was designed to assess the relative impact of fit test exercises and mask donning on respirator fit as measured by a controlled negative pressure and an ambient aerosol fit test system. Multiple donnings of two different sizes of identical respirator models by each of 14 test subjects showed that donning affects respirator fit to a greater degree than fit test exercises. Currently specified fit test protocols emphasize test exercises, and the determination of fit is based on a single mask donning. A rationale for a modified fit test protocol based on fewer, more targeted test exercises and multiple mask donnings is presented. The modified protocol identified inadequately fitting respirators as effectively as the currently specified Occupational Safety and Health Administration (OSHA) quantitative fit test protocol. The controlled negative pressure system measured significantly (p < 0.0001) more respirator leakage than the ambient aerosol fit test system. The bend over fit test exercise was found to be predictive of poor respirator fit by both fit test systems. For the better fitting respirators, only the talking exercise generated aerosol fit factors that were significantly lower (p < 0.0001) than corresponding donning fit factors.

  8. Masking overshoot: Effects of ipsilateral, bilateral and contralateral priming

    NASA Astrophysics Data System (ADS)

    Connington, Maureen Catherine

    This study was concerned with masking overshoot, the elevation of the threshold of a brief signal when it is presented at the onset of a masking noise rather than at its temporal center. More specifically, it was concerned with the release from overshoot (i.e., threshold improvement) produced by priming stimuli, presented ipsilaterally, bilaterally and contralaterally at primer- masker gaps of 20, 40 and 80 msec. The more general purpose of the study was to assess the contributions of peripheral and central factors to the overshoot and overshoot-release phenomena. The primers and masking stimuli consisted of white noise bursts of 200 and 400 msec duration, respectively. The probe signal was a 20 msec 4kHz tone. The tone and masker were always presented in one ear. There were, however, 3 modes of primer presentation: ipsilateral, bilateral (identical waveforms to both ears) and contralateral. Three primer-masker gaps of 20, 40 and 80 msec were used. Five normally hearing adults were tested at primer and masker levels of 80 dB HL. Four of the five subjects exhibited significant masking overshoot, when tested without priming. Ipsilateral priming with 20 and 40 msec gaps produced significant masking release from overshoot. Threshold became poorer, however with increasing gap duration and with increasing distance of the perceived primer from the test ear (i.e. ipsilateral priming produced better thresholds than did bilateral priming and bilateral priming produced better thresholds than contralateral priming). There was significant masking enhancement (i.e. threshold was significantly poorer than in the unprimed probe at onset condition) with the contralateral 80 msec primer. The fact that ipsilateral and bilateral primers performed differently does not support the theory that masking overshoot and its release are solely the results of peripheral adaptation. In fact, the group results support the conclusion that masking overshoot is influenced by central factors. However, there were marked inter-subject differences. It seems possible that masking overshoot and its release are influenced by both peripheral adaptation effects and central processes and that the balance between the two is subject-dependent.

  9. Summation versus suppression in metacontrast masking: On the potential pitfalls of using metacontrast masking to assess perceptual-motor dissociation.

    PubMed

    Cardoso-Leite, Pedro; Waszak, Florian

    2014-07-01

    A briefly flashed target stimulus can become "invisible" when immediately followed by a mask-a phenomenon known as backward masking, which constitutes a major tool in the cognitive sciences. One form of backward masking is termed metacontrast masking. It is generally assumed that in metacontrast masking, the mask suppresses activity on which the conscious perception of the target relies. This assumption biases conclusions when masking is used as a tool-for example, to study the independence between perceptual detection and motor reaction. This is because other models can account for reduced perceptual performance without requiring suppression mechanisms. In this study, we used signal detection theory to test the suppression model against an alternative view of metacontrast masking, referred to as the summation model. This model claims that target- and mask-related activations fuse and that the difficulty in detecting the target results from the difficulty to discriminate this fused response from the response produced by the mask alone. Our data support this alternative view. This study is not a thorough investigation of metacontrast masking. Instead, we wanted to point out that when a different model is used to account for the reduced perceptual performance in metacontrast masking, there is no need to postulate a dissociation between perceptual and motor responses to account for the data. Metacontrast masking, as implemented in the Fehrer-Raab situation, therefore is not a valid method to assess perceptual-motor dissociations.

  10. Human frequency-following response to speech-like sounds: correlates of off-frequency masking.

    PubMed

    Krishnan, Ananthanarayan; Agrawal, Smita

    2010-01-01

    Off-frequency masking of the second formant by energy at the first formant has been shown to influence both identification and discrimination of the second formant in normal-hearing and hearing-impaired listeners. While both excitatory spread and two-tone suppression have been implicated in this simultaneous masking, their relative contribution has been shown to depend on both the level of the masker and the frequency separation between the probe and the masker. Off-frequency masking effects were evaluated in 10 normal-hearing human adults using the frequency-following response (FFR) to two two-tone approximations of vowel stimuli (/a/ and /u/). In the first experiment, the masking effect of F(1) on F(2) was evaluated by attenuating the level of F(1) relative to a fixed F(2) level. In the second experiment, the masking effect was evaluated by increasing the frequency separation between F(1) and F(2) using F(2) frequency as the variable. Results revealed that both attenuation of the F(1) level, and increasing the frequency separation between F(1) and F(2) increased the magnitude of the FFR component at F(2). These results are consistent with a release from off-frequency masking. Given that the results presented here are for high signal and masker levels and for relatively smaller frequency separation between the masker and the probe, it is possible that both suppression and excitatory spread contributed to the masking effects observed in our data. Copyright2009 S. Karger AG, Basel.

  11. Are personality traits associated with white-coat and masked hypertension?

    PubMed

    Terracciano, Antonio; Scuteri, Angelo; Strait, James; Sutin, Angelina R; Meirelles, Osorio; Marongiu, Michele; Orru, Marco; Pilia, Maria Grazia; Ferrucci, Luigi; Cucca, Francesco; Schlessinger, David; Lakatta, Edward

    2014-10-01

    Anxiety and other psychological dispositions are thought to be associated with blood pressure. This study tests whether personality traits have long-term associations with masked and white-coat effects. A community-based sample of 2838 adults from Sardinia (Italy) completed the Revised NEO Personality Inventory, and 7 years later, blood pressure was assessed in the clinic and with ambulatory monitoring. Logistic regressions were used to test whether anxiety, neuroticism, extraversion, openness, agreeableness, and conscientiousness predicted the white-coat and masked hypertension phenomena. Age, sex, and antihypertensive medication use were tested as moderators. Significant interactions were found between personality traits and antihypertensive medications in predicting masked and white-coat effects. Only among those taking antihypertensive medication, higher anxiety was associated with a higher risk of pseudo-resistant hypertension due to white-coat effect (odds ratio 1.39, 95% confidence interval 1.01-1.91) and higher conscientiousness was associated with a lower risk of masked uncontrolled hypertension (odds ratio 0.70, 95% confidence interval 0.49-0.99). There were no significant interactions with age or sex. Among those on antihypertensive medications, anxious individuals were more likely to have pseudo-resistant hypertension due to white-coat effect and less conscientious individuals were at increased risk of masked uncontrolled hypertension. Particularly among anxious and less conscientious individuals, ambulatory monitoring may improve the tailoring of pharmacological treatments.

  12. Differential effect of visual masking in perceptual categorization.

    PubMed

    Hélie, Sébastien; Cousineau, Denis

    2015-06-01

    This article explores the visual information used to categorize stimuli drawn from a common stimulus space into verbal and nonverbal categories using 2 experiments. Experiment 1 explores the effect of target duration on verbal and nonverbal categorization using backward masking to interrupt visual processing. With categories equated for difficulty for long and short target durations, intermediate target duration shows an advantage for verbal categorization over nonverbal categorization. Experiment 2 tests whether the results of Experiment 1 can be explained by shorter target duration resulting in a smaller signal-to-noise ratio of the categorization stimulus. To test for this possibility, Experiment 2 used integration masking with the same stimuli, categories, and masks as Experiment 1 with a varying level of mask opacity. As predicted, low mask opacity yielded similar results to long target duration while high mask opacity yielded similar results to short target duration. Importantly, intermediate mask opacity produced an advantage for verbal categorization over nonverbal categorization, similar to intermediate target duration. These results suggest that verbal and nonverbal categorization are affected differently by manipulations affecting the signal-to-noise ratio of the stimulus, consistent with multiple-system theories of categorizations. The results further suggest that verbal categorization may be more digital (and more robust to low signal-to-noise ratio) while the information used in nonverbal categorization may be more analog (and less robust to lower signal-to-noise ratio). This article concludes with a discussion of how these new results affect the use of masking in perceptual categorization and multiple-system theories of perceptual category learning. (c) 2015 APA, all rights reserved).

  13. Low cost solar array project cell and module formation research area: Process research of non-CZ silicon material

    NASA Technical Reports Server (NTRS)

    1981-01-01

    Liquid diffusion masks and liquid applied dopants to replace the CVD Silox masking and gaseous diffusion operations specified for forming junctions in the Westinghouse baseline process sequence for producing solar cells from dendritic web silicon were investigated. The baseline diffusion masking and drive processes were compared with those involving direct liquid applications to the dendritic web silicon strips. Attempts were made to control the number of variables by subjecting dendritic web strips cut from a single web crystal to both types of operations. Data generated reinforced earlier conclusions that efficiency levels at least as high as those achieved with the baseline back junction formation process can be achieved using liquid diffusion masks and liquid dopants. The deliveries of dendritic web sheet material and solar cells specified by the current contract were made as scheduled.

  14. Jitter Reduces Response-Time Variability in ADHD: An Ex-Gaussian Analysis.

    PubMed

    Lee, Ryan W Y; Jacobson, Lisa A; Pritchard, Alison E; Ryan, Matthew S; Yu, Qilu; Denckla, Martha B; Mostofsky, Stewart; Mahone, E Mark

    2015-09-01

    "Jitter" involves randomization of intervals between stimulus events. Compared with controls, individuals with ADHD demonstrate greater intrasubject variability (ISV) performing tasks with fixed interstimulus intervals (ISIs). Because Gaussian curves mask the effect of extremely slow or fast response times (RTs), ex-Gaussian approaches have been applied to study ISV. This study applied ex-Gaussian analysis to examine the effects of jitter on RT variability in children with and without ADHD. A total of 75 children, aged 9 to 14 years (44 ADHD, 31 controls), completed a go/no-go test with two conditions: fixed ISI and jittered ISI. ADHD children showed greater variability, driven by elevations in exponential (tau), but not normal (sigma) components of the RT distribution. Jitter decreased tau in ADHD to levels not statistically different than controls, reducing lapses in performance characteristic of impaired response control. Jitter may provide a nonpharmacologic mechanism to facilitate readiness to respond and reduce lapses from sustained (controlled) performance. © 2012 SAGE Publications.

  15. Exposure to noise during continuous positive airway pressure: influence of interfaces and delivery systems.

    PubMed

    Cavaliere, F; Conti, G; Costa, R; Spinazzola, G; Proietti, R; Sciuto, A; Masieri, S

    2008-01-01

    We measured noise intensity and perceived noisiness during continuous positive airway pressure (CPAP) performed with two interfaces (face-mask, helmet) and four delivery systems. Eight healthy volunteers received CPAP in random order with: two systems provided with a flow generator using the Venturi effect and a mechanical expiratory valve (A: Venturi, Starmed; B: Whisperflow-2, Caradyne Ltd); one 'free-flow' system provided with high flow O(2) and air flowmeters, an inspiratory gas reservoir, and a water valve (C: CF800, Drägerwerk, AG); and a standard mechanical ventilator (Servoventilator 300, Siemens-Elema). Systems A, B, and C were tested with a face-mask and a helmet at a CPAP value of 10 cm H(2)O; the mechanical ventilator was only tested with the face mask. Noise intensity was measured with a sound-level meter. After each test, participants scored noisiness on a visual analog scale (VAS). The noise levels measured ranged from 57+/-11 dBA (mechanical ventilator plus mask) to 93+/-1 and 94+/-2 dBA (systems A and B plus helmet) and were significantly affected by CPAP systems (A and B noisier than C and D) and interfaces (helmet CPAP noisier than mask CPAP). Subjective evaluation showed that systems A and B plus helmet were perceived as noisier than system C plus mask or helmet. Maximum noise levels observed in this study may potentially cause patient discomfort. Less noisy CPAP systems (not using Venturi effect) and interfaces (facial mask better than helmet) should be preferred, particularly for long or nocturnal treatments.

  16. Wafer hot spot identification through advanced photomask characterization techniques: part 2

    NASA Astrophysics Data System (ADS)

    Choi, Yohan; Green, Michael; Cho, Young; Ham, Young; Lin, Howard; Lan, Andy; Yang, Richer; Lung, Mike

    2017-03-01

    Historically, 1D metrics such as Mean to Target (MTT) and CD Uniformity (CDU) have been adequate for mask end users to evaluate and predict the mask impact on the wafer process. However, the wafer lithographer's process margin is shrinking at advanced nodes to a point that classical mask CD metrics are no longer adequate to gauge the mask contribution to wafer process error. For example, wafer CDU error at advanced nodes is impacted by mask factors such as 3-dimensional (3D) effects and mask pattern fidelity on sub-resolution assist features (SRAFs) used in Optical Proximity Correction (OPC) models of ever-increasing complexity. To overcome the limitation of 1D metrics, there are numerous on-going industry efforts to better define wafer-predictive metrics through both standard mask metrology and aerial CD methods. Even with these improvements, the industry continues to struggle to define useful correlative metrics that link the mask to final device performance. In part 1 of this work, we utilized advanced mask pattern characterization techniques to extract potential hot spots on the mask and link them, theoretically, to issues with final wafer performance. In this paper, part 2, we complete the work by verifying these techniques at wafer level. The test vehicle (TV) that was used for hot spot detection on the mask in part 1 will be used to expose wafers. The results will be used to verify the mask-level predictions. Finally, wafer performance with predicted and verified mask/wafer condition will be shown as the result of advanced mask characterization. The goal is to maximize mask end user yield through mask-wafer technology harmonization. This harmonization will provide the necessary feedback to determine optimum design, mask specifications, and mask-making conditions for optimal wafer process margin.

  17. A new suction mask to reduce leak during neonatal resuscitation: a manikin study.

    PubMed

    Lorenz, Laila; Maxfield, Dominic A; Dawson, Jennifer A; Kamlin, C Omar F; McGrory, Lorraine; Thio, Marta; Donath, Susan M; Davis, Peter G

    2016-09-01

    Leak around the face mask is a common problem during neonatal resuscitation. A newly designed face mask using a suction system to enhance contact between the mask and the infant's face might reduce leak and improve neonatal resuscitation. The aim of the study is to determine whether leak is reduced using the suction mask (Resusi-sure mask) compared with a conventional mask (Laerdal Silicone mask) in a manikin model. Sixty participants from different professional categories (neonatal consultants, fellows, registrars, nurses, midwives and students) used each face mask in a random order to deliver 2 min of positive pressure ventilation to a manikin. Delivered airway pressures were measured using a pressure line. Inspiratory and expiratory flows were measured using a flow sensor, and expiratory tidal volumes and mask leaks were derived from these values. A median (IQR) leak of 12.1 (0.6-39.0)% was found with the conventional mask compared with 0.7 (0.2-4.6)% using the suction mask (p=0.002). 50% of the participants preferred to use the suction mask and 38% preferred to use the conventional mask. There was no correlation between leak and operator experience. A new neonatal face mask based on the suction system reduced leak in a manikin model. Clinical studies to test the safety and effectiveness of this mask are needed. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  18. Antigen Masking During Fixation and Embedding, Dissected

    PubMed Central

    Scalia, Carla Rossana; Boi, Giovanna; Bolognesi, Maddalena Maria; Riva, Lorella; Manzoni, Marco; DeSmedt, Linde; Bosisio, Francesca Maria; Ronchi, Susanna; Leone, Biagio Eugenio; Cattoretti, Giorgio

    2016-01-01

    Antigen masking in routinely processed tissue is a poorly understood process caused by multiple factors. We sought to dissect the effect on antigenicity of each step of processing by using frozen sections as proxies of the whole tissue. An equivalent extent of antigen masking occurs across variable fixation times at room temperature. Most antigens benefit from longer fixation times (>24 hr) for optimal detection after antigen retrieval (AR; for example, Ki-67, bcl-2, ER). The transfer to a graded alcohol series results in an enhanced staining effect, reproduced by treating the sections with detergents, possibly because of a better access of the polymeric immunohistochemical detection system to tissue structures. A second round of masking occurs upon entering the clearing agent, mostly at the paraffin embedding step. This may depend on the non-freezable water removal. AR fully reverses the masking due both to the fixation time and the paraffin embedding. AR itself destroys some epitopes which do not survive routine processing. Processed frozen sections are a tool to investigate fixation and processing requirements for antigens in routine specimens. PMID:27798289

  19. Secondary gamma-ray production in a coded aperture mask

    NASA Technical Reports Server (NTRS)

    Owens, A.; Frye, G. M., Jr.; Hall, C. J.; Jenkins, T. L.; Pendleton, G. N.; Carter, J. N.; Ramsden, D.; Agrinier, B.; Bonfand, E.; Gouiffes, C.

    1985-01-01

    The application of the coded aperture mask to high energy gamma-ray astronomy will provide the capability of locating a cosmic gamma-ray point source with a precision of a few arc-minutes above 20 MeV. Recent tests using a mask in conjunction with drift chamber detectors have shown that the expected point spread function is achieved over an acceptance cone of 25 deg. A telescope employing this technique differs from a conventional telescope only in that the presence of the mask modifies the radiation field in the vicinity of the detection plane. In addition to reducing the primary photon flux incident on the detector by absorption in the mask elements, the mask will also be a secondary radiator of gamma-rays. The various background components in a CAMTRAC (Coded Aperture Mask Track Chamber) telescope are considered. Monte-Carlo calculations are compared with recent measurements obtained using a prototype instrument in a tagged photon beam line.

  20. [Effect of a surgical mask on six minute walking distance].

    PubMed

    Person, E; Lemercier, C; Royer, A; Reychler, G

    2018-03-01

    Six minutes walking test (6MWT) is regularly used in pulmonology. To minimize the risk of cross-infection, some patients must wear surgical mask at rest and sometimes during exercise. To evaluate the effect of wearing a surgical mask during 6MWT in healthy subjects. It is a prospective study on 44 healthy subjects. After a first 6MWT for training, they performed randomly two 6MWT: with or without a surgical mask. Distance and dyspnea, heart rate and saturation variations were recorded. Distance was not modified by the mask (P=0.99). Dyspnea variation was significantly higher with surgical mask (+5.6 vs. +4.6; P<0.001) and the difference was clinically relevant. No difference was found for the variation of other parameters. Wearing a surgical mask modifies significantly and clinically dyspnea without influencing walked distance. Copyright © 2017 SPLF. Published by Elsevier Masson SAS. All rights reserved.

  1. Three-dimensional printing for restoration of the donor face: A new digital technique tested and used in the first facial allotransplantation patient in Finland.

    PubMed

    Mäkitie, A A; Salmi, M; Lindford, A; Tuomi, J; Lassus, P

    2016-12-01

    Prosthetic mask restoration of the donor face is essential in current facial transplant protocols. The aim was to develop a new three-dimensional (3D) printing (additive manufacturing; AM) process for the production of a donor face mask that fulfilled the requirements for facial restoration after facial harvest. A digital image of a single test person's face was obtained in a standardized setting and subjected to three different image processing techniques. These data were used for the 3D modeling and printing of a donor face mask. The process was also tested in a cadaver setting and ultimately used clinically in a donor patient after facial allograft harvest. and Conclusions: All the three developed and tested techniques enabled the 3D printing of a custom-made face mask in a timely manner that is almost an exact replica of the donor patient's face. This technique was successfully used in a facial allotransplantation donor patient. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  2. Identification of Dust Source Regions at High-Resolution and Dynamics of Dust Source Mask over Southwest United States Using Remote Sensing Data

    NASA Astrophysics Data System (ADS)

    Sprigg, W. A.; Sahoo, S.; Prasad, A. K.; Venkatesh, A. S.; Vukovic, A.; Nickovic, S.

    2015-12-01

    Identification and evaluation of sources of aeolian mineral dust is a critical task in the simulation of dust. Recently, time series of space based multi-sensor satellite images have been used to identify and monitor changes in the land surface characteristics. Modeling of windblown dust requires precise delineation of mineral dust source and its strength that varies over a region as well as seasonal and inter-annual variability due to changes in land use and land cover. Southwest USA is one of the major dust emission prone zone in North American continent where dust is generated from low lying dried-up areas with bare ground surface and they may be scattered or appear as point sources on high resolution satellite images. In the current research, various satellite derived variables have been integrated to produce a high-resolution dust source mask, at grid size of 250 m, using data such as digital elevation model, surface reflectance, vegetation cover, land cover class, and surface wetness. Previous dust source models have been adopted to produce a multi-parameter dust source mask using data from satellites such as Terra (Moderate Resolution Imaging Spectroradiometer - MODIS), and Landsat. The dust source mask model captures the topographically low regions with bare soil surface, dried-up river plains, and lakes which form important source of dust in southwest USA. The study region is also one of the hottest regions of USA where surface dryness, land use (agricultural use), and vegetation cover changes significantly leading to major changes in the areal coverage of potential dust source regions. A dynamic high resolution dust source mask have been produced to address intra-annual change in the aerial extent of bare dry surfaces. Time series of satellite derived data have been used to create dynamic dust source masks. A new dust source mask at 16 day interval allows enhanced detection of potential dust source regions that can be employed in the dust emission and transport pathways models for better estimation of emission of dust during dust storms, particulate air pollution, public health risk assessment tools and decision support systems.

  3. Using automated texture features to determine the probability for masking of a tumor on mammography, but not ultrasound.

    PubMed

    Häberle, Lothar; Hack, Carolin C; Heusinger, Katharina; Wagner, Florian; Jud, Sebastian M; Uder, Michael; Beckmann, Matthias W; Schulz-Wendtland, Rüdiger; Wittenberg, Thomas; Fasching, Peter A

    2017-08-30

    Tumors in radiologically dense breast were overlooked on mammograms more often than tumors in low-density breasts. A fast reproducible and automated method of assessing percentage mammographic density (PMD) would be desirable to support decisions whether ultrasonography should be provided for women in addition to mammography in diagnostic mammography units. PMD assessment has still not been included in clinical routine work, as there are issues of interobserver variability and the procedure is quite time consuming. This study investigated whether fully automatically generated texture features of mammograms can replace time-consuming semi-automatic PMD assessment to predict a patient's risk of having an invasive breast tumor that is visible on ultrasound but masked on mammography (mammography failure). This observational study included 1334 women with invasive breast cancer treated at a hospital-based diagnostic mammography unit. Ultrasound was available for the entire cohort as part of routine diagnosis. Computer-based threshold PMD assessments ("observed PMD") were carried out and 363 texture features were obtained from each mammogram. Several variable selection and regression techniques (univariate selection, lasso, boosting, random forest) were applied to predict PMD from the texture features. The predicted PMD values were each used as new predictor for masking in logistic regression models together with clinical predictors. These four logistic regression models with predicted PMD were compared among themselves and with a logistic regression model with observed PMD. The most accurate masking prediction was determined by cross-validation. About 120 of the 363 texture features were selected for predicting PMD. Density predictions with boosting were the best substitute for observed PMD to predict masking. Overall, the corresponding logistic regression model performed better (cross-validated AUC, 0.747) than one without mammographic density (0.734), but less well than the one with the observed PMD (0.753). However, in patients with an assigned mammography failure risk >10%, covering about half of all masked tumors, the boosting-based model performed at least as accurately as the original PMD model. Automatically generated texture features can replace semi-automatically determined PMD in a prediction model for mammography failure, such that more than 50% of masked tumors could be discovered.

  4. Characterizing the reflectivity of handheld display devices.

    PubMed

    Liu, Peter; Badano, Aldo

    2014-08-01

    With increased use of handheld and tablet display devices for viewing medical images, methods for consistently measuring reflectivity of the devices are needed. In this note, the authors report on the characterization of diffuse reflections for handheld display devices including mobile phones and tablets using methods recommended by the American Association of Physicists in Medicine Task Group 18 (TG18). The authors modified the diffuse reflectance coefficient measurement method outlined in the TG18 report. The authors measured seven handheld display devices (two phones and five tablets) and three workstation displays. The device was attached to a black panel with Velcro. To study the effect of the back surface on the diffuse reflectance coefficient, the authors created Styrofoam masks with different size square openings and placed it in front of the device. Overall, for each display device, measurements of illuminance and reflected luminance on the display screen were taken. The authors measured with no mask, with masks of varying size, and with display-size masks, and calculated the corresponding diffuse reflectance coefficient. For all handhelds, the diffuse reflectance coefficient measured with no back panel were lower than measurements performed with a mask. The authors found an overall increase in reflectivity as the size of the mask decreases. For workstations displays, diffuse reflectance coefficients were higher when no back panel was used, and higher than with masks. In all cases, as luminance increased, illuminance increased, but not at the same rate. Since the size of handheld displays is smaller than that of workstation devices, the TG18 method suffers from a dependency on illumination condition. The authors show that the diffuse reflection coefficients can vary depending on the nature of the back surface of the illuminating box. The variability in the diffuse coefficient can be as large as 20% depending on the size of the mask. For all measurements, both luminance and illuminance increased as the size of the display window decreased. The TG18 method does not account for this variability. The authors conclude that the method requires a definitive description of the back panel used in the light source setup. The methods described in the TG18 document may need to be improved to provide consistent comparisons of desktop monitors, phones, and tablets.

  5. Propagation of resist heating mask error to wafer level

    NASA Astrophysics Data System (ADS)

    Babin, S. V.; Karklin, Linard

    2006-10-01

    As technology is approaching 45 nm and below the IC industry is experiencing a severe product yield hit due to rapidly shrinking process windows and unavoidable manufacturing process variations. Current EDA tools are unable by their nature to deliver optimized and process-centered designs that call for 'post design' localized layout optimization DFM tools. To evaluate the impact of different manufacturing process variations on final product it is important to trace and evaluate all errors through design to manufacturing flow. Photo mask is one of the critical parts of this flow, and special attention should be paid to photo mask manufacturing process and especially to mask tight CD control. Electron beam lithography (EBL) is a major technique which is used for fabrication of high-end photo masks. During the writing process, resist heating is one of the sources for mask CD variations. Electron energy is released in the mask body mainly as heat, leading to significant temperature fluctuations in local areas. The temperature fluctuations cause changes in resist sensitivity, which in turn leads to CD variations. These CD variations depend on mask writing speed, order of exposure, pattern density and its distribution. Recent measurements revealed up to 45 nm CD variation on the mask when using ZEP resist. The resist heating problem with CAR resists is significantly smaller compared to other types of resists. This is partially due to higher resist sensitivity and the lower exposure dose required. However, there is no data yet showing CD errors on the wafer induced by CAR resist heating on the mask. This effect can be amplified by high MEEF values and should be carefully evaluated at 45nm and below technology nodes where tight CD control is required. In this paper, we simulated CD variation on the mask due to resist heating; then a mask pattern with the heating error was transferred onto the wafer. So, a CD error on the wafer was evaluated subject to only one term of the mask error budget - the resist heating CD error. In simulation of exposure using a stepper, variable MEEF was considered.

  6. What You May Not See Might Slow You Down Anyway: Masked Images and Driving

    PubMed Central

    Lewis-Evans, Ben; de Waard, Dick; Jolij, Jacob; Brookhuis, Karel A.

    2012-01-01

    Many theories of driver behaviour suggest that unconscious or implicit emotions play a functional role in the shaping and control of behaviour. This has not been experimentally tested however. Therefore, in this study the effects of emotive masked images on driver behaviour were examined. While driving a simulator, participants were repeatedly exposed to negative or neutral emotionally laden target images that were sandwich masked by emotionally neutral images. These images were encountered across two different trials each of which consisted of 3–4 minutes of driving on a rural road. The results indicate an effect of the negative target images primarily in reducing the extent of familiarisation occurring between the first and second experimental drives. This is evident in a reduced decrease in heart rate and a reduced increase in high band heart rate variability and actual travelling speed from the first to second drives if the negative target image was presented in the second drive. In addition to these findings there was no clear effect of the target image on subjective ratings of effort or feelings of risk. There was however an effect of gender, with the majority of the effects found in the study being limited to the larger female dataset. These findings suggest that unconscious or implicit emotional stimuli may well influence driver behaviour without explicit awareness. PMID:22279549

  7. Edge-illumination x-ray phase contrast imaging with Pt-based metallic glass masks

    NASA Astrophysics Data System (ADS)

    Saghamanesh, Somayeh; Aghamiri, Seyed Mahmoud-Reza; Olivo, Alessandro; Sadeghilarijani, Maryam; Kato, Hidemi; Kamali-Asl, Alireza; Yashiro, Wataru

    2017-06-01

    Edge-illumination x-ray phase contrast imaging (EI XPCI) is a non-interferometric phase-sensitive method where two absorption masks are employed. These masks are fabricated through a photolithography process followed by electroplating which is challenging in terms of yield as well as time- and cost-effectiveness. We report on the first implementation of EI XPCI with Pt-based metallic glass masks fabricated by an imprinting method. The new tested alloy exhibits good characteristics including high workability beside high x-ray attenuation. The fabrication process is easy and cheap, and can produce large-size masks for high x-ray energies within minutes. Imaging experiments show a good quality phase image, which confirms the potential of these masks to make the EI XPCI technique widely available and affordable.

  8. Assessing the Effect of Early Visual Cortex Transcranial Magnetic Stimulation on Working Memory Consolidation.

    PubMed

    van Lamsweerde, Amanda E; Johnson, Jeffrey S

    2017-07-01

    Maintaining visual working memory (VWM) representations recruits a network of brain regions, including the frontal, posterior parietal, and occipital cortices; however, it is unclear to what extent the occipital cortex is engaged in VWM after sensory encoding is completed. Noninvasive brain stimulation data show that stimulation of this region can affect working memory (WM) during the early consolidation time period, but it remains unclear whether it does so by influencing the number of items that are stored or their precision. In this study, we investigated whether single-pulse transcranial magnetic stimulation (spTMS) to the occipital cortex during VWM consolidation affects the quantity or quality of VWM representations. In three experiments, we disrupted VWM consolidation with either a visual mask or spTMS to retinotopic early visual cortex. We found robust masking effects on the quantity of VWM representations up to 200 msec poststimulus offset and smaller, more variable effects on WM quality. Similarly, spTMS decreased the quantity of VWM representations, but only when it was applied immediately following stimulus offset. Like visual masks, spTMS also produced small and variable effects on WM precision. The disruptive effects of both masks and TMS were greatly reduced or entirely absent within 200 msec of stimulus offset. However, there was a reduction in swap rate across all time intervals, which may indicate a sustained role of the early visual cortex in maintaining spatial information.

  9. Analysis of the ability of catcher's masks to attenuate head accelerations on impact with a baseball.

    PubMed

    Shain, Kellen S; Madigan, Michael L; Rowson, Steven; Bisplinghoff, Jill; Duma, Stefan M

    2010-11-01

    The goals of this study were to measure the ability of catcher's masks to attenuate head accelerations on impact with a baseball and to compare these head accelerations to established injury thresholds for mild traumatic brain injury. Testing involved using a pneumatic cannon to shoot baseballs at an instrumented Hybrid III headform (a 50th percentile male head and neck) with and without a catcher's mask on the head. The ball speed was controlled from approximately 26.8 to 35.8 m/s (60-80 mph), and the regulation National Collegiate Athletic Association baseballs were used. Research laboratory. None. Catcher's masks and impact velocity. The linear and angular head accelerations of the Hybrid III headform. Peak linear resultant acceleration was 140 to 180 g without a mask and 16 to 30 g with a mask over the range of ball's speed investigated. Peak angular resultant acceleration was 19 500 to 25 700 rad/s without a mask and 2250 to 3230 rad/s with a mask. The Head Injury Criterion was 93 to 181 without a mask and 3 to 13 with a mask, and the Severity Index was 110 to 210 without a mask and 3 to 15 with a mask. Catcher's masks reduced head acceleration metrics by approximately 85%. Head acceleration metrics with a catcher's mask were significantly lower than contemporary injury thresholds, yet reports in the mass media clearly indicate that baseball impacts to the mask still occasionally result in mild traumatic brain injuries. Further research is needed to address this apparent contradiction.

  10. Accurate masking technology for high-resolution powder blasting

    NASA Astrophysics Data System (ADS)

    Pawlowski, Anne-Gabrielle; Sayah, Abdeljalil; Gijs, Martin A. M.

    2005-07-01

    We have combined eroding 10 µm diameter Al2O3 particles with a new masking technology to realize the smallest and most accurate possible structures by powder blasting. Our masking technology is based on the sequential combination of two polymers:(i) the brittle epoxy resin SU8 for its photosensitivity and (ii) the elastic and thermocurable poly-dimethylsiloxane for its large erosion resistance. We have micropatterned various types of structures with a minimum width of 20 µm for test structures with an aspect ratio of 1, and 50 µm for test structures with an aspect ratio of 2.

  11. Alternating phase-shift mask and binary mask for 45-nm node and beyond: the impact on the mask error control

    NASA Astrophysics Data System (ADS)

    Kojima, Yosuke; Shirasaki, Masanori; Chiba, Kazuaki; Tanaka, Tsuyoshi; Inazuki, Yukio; Yoshikawa, Hiroki; Okazaki, Satoshi; Iwase, Kazuya; Ishikawa, Kiichi; Ozawa, Ken

    2007-05-01

    For 45 nm node and beyond, the alternating phase-shift mask (alt. PSM), one of the most expected resolution enhancement technologies (RET) because of its high image contrast and small mask error enhancement factor (MEEF), and the binary mask (BIM) attract attention. Reducing CD and registration errors and defect are their critical issues. As the solution, the new blank for alt. PSM and BIM is developed. The top film of new blank is thin Cr, and the antireflection film and shielding film composed of MoSi are deposited under the Cr film. The mask CD performance is evaluated for through pitch, CD linearity, CD uniformity, global loading, resolution and pattern fidelity, and the blank performance is evaluated for optical density, reflectivity, sheet resistance, flatness and defect level. It is found that the performance of new blank is equal to or better than that of conventional blank in all items. The mask CD performance shows significant improvement. The lithography performance of new blank is confirmed by wafer printing and AIMS measurement. The full dry type alt. PSM has been used as test plate, and the test results show that new blank can almost meet the specifications of pi-0 CD difference, CD uniformity and process margin for 45 nm node. Additionally, the new blank shows the better pattern fidelity than that of conventional blank on wafer. AIMS results are almost same as wafer results except for the narrowest pattern. Considering the result above, this new blank can reduce the mask error factors of alt. PSM and BIM for 45 nm node and beyond.

  12. Excitation-based and informational masking of a tonal signal in a four-tone masker.

    PubMed

    Leibold, Lori J; Hitchens, Jack J; Buss, Emily; Neff, Donna L

    2010-04-01

    This study examined contributions of peripheral excitation and informational masking to the variability in masking effectiveness observed across samples of multi-tonal maskers. Detection thresholds were measured for a 1000-Hz signal presented simultaneously with each of 25, four-tone masker samples. Using a two-interval, forced-choice adaptive task, thresholds were measured with each sample fixed throughout trial blocks for ten listeners. Average thresholds differed by as much as 26 dB across samples. An excitation-based model of partial loudness [Moore, B. C. J. et al. (1997). J. Audio Eng. Soc. 45, 224-237] was used to predict thresholds. These predictions accounted for a significant portion of variance in the data of several listeners, but no relation between the model and data was observed for many listeners. Moreover, substantial individual differences, on the order of 41 dB, were observed for some maskers. The largest individual differences were found for maskers predicted to produce minimal excitation-based masking. In subsequent conditions, one of five maskers was randomly presented in each interval. The difference in performance for samples with low versus high predicted thresholds was reduced in random compared to fixed conditions. These findings are consistent with a trading relation whereby informational masking is largest for conditions in which excitation-based masking is smallest.

  13. Reticle writer for next-generation SEMI mask standard: mask handling and exposure

    NASA Astrophysics Data System (ADS)

    Ehrlich, Christian

    1998-12-01

    The world semiconductor industry is currently preparing itself for the next evolutionary step in the ongoing development of the integrated circuit, characterized by the 0.18 to 0.15 micrometer technology. The already complex engineering task for the mask tool makers is furthermore complicated by the introduction of the new SEMI reticle standard with a 230 mm by 230 mm large and 9 mm thick quartz glass blank that will have a weight of more than one kilogram. The production of these advanced masks is already identified as a key enabling technology which will stretch the capabilities of the manufacturing process, and its equipment, to the limit. The mask making e-beam system Leica ZBA320, capable of exposing a 230 mm reticle and featuring the variable shaped beam approach with a 20 kV accelerating voltage has been introduced recently. Now the first results of e-beam exposures with this new type of mask writer are presented. Enhancements form the previous generation system include improved deflection systems, stage metrology, pattern data handling, and an address grid down to 10 nanometers. This system's specified performance enables it to produce reticles designed to support semiconductor fabrication utilizing 180 nanometer design rules, and beyond, with high accuracy and productivity.

  14. The Effect Of Digital Unsharp Masking On The Detectability Of Interstitial Infiltrates And Pneumothoraces

    NASA Astrophysics Data System (ADS)

    MacMahon, Heber; Vyborny, Carl; Sabeti, Victoria; Metz, Charles; Doi, Kunio

    1985-09-01

    A potential advantage of digital radiographic systems is their ability to enhance images by various types of processing. Digital unsharp masking is one of the simplest and potentially most useful forms of enhancement. The efficacy of unsharp masking in clinical radiologic diagnosis has not been investigated systematically, however. The effect of digital unsharp masking on the detectability of two types of subtle abnormalities, pneumothorax and interstitial infiltrate, was studied in an observer performance test. An ROC analysis of this preliminary data suggests that unsharp masking may improve diagnostic accuracy for pneumothorax. Radiologists' performance in identifying interstitial infiltrates was degraded by the image processing, however, and false positive diagnoses tended to be more frequent.

  15. Digital sun sensor multi-spot operation.

    PubMed

    Rufino, Giancarlo; Grassi, Michele

    2012-11-28

    The operation and test of a multi-spot digital sun sensor for precise sun-line determination is described. The image forming system consists of an opaque mask with multiple pinhole apertures producing multiple, simultaneous, spot-like images of the sun on the focal plane. The sun-line precision can be improved by averaging multiple simultaneous measures. Nevertheless, the sensor operation on a wide field of view requires acquiring and processing images in which the number of sun spots and the related intensity level are largely variable. To this end, a reliable and robust image acquisition procedure based on a variable shutter time has been considered as well as a calibration function exploiting also the knowledge of the sun-spot array size. Main focus of the present paper is the experimental validation of the wide field of view operation of the sensor by using a sensor prototype and a laboratory test facility. Results demonstrate that it is possible to keep high measurement precision also for large off-boresight angles.

  16. Bias in masked word identification: unconscious influences of repetition priming.

    PubMed

    Masson, Michael E J

    2002-12-01

    The beneficial influence of a prior study episode on subsequent identification of a word includes a large bias component, revealed in the forced-choice variant of the masked word identification test. In that type of test, subjects show a preference for a studied probe over a nonstudied probe, regardless of which one matches the masked target word. The forced-choice test was used in the present experiments to test the possibility that this bias effect is due to conscious recollection. Results show that bias was strongly attenuated (1) by changes in modality between study and test, and (2) under certain conditions, by using a conceptually driven study task. The bias effect was found only when probes were orthographically similar to one another, as predicted by the counter model (Ratcliff & McKoon, 1997). These results provide strong evidence that the bias effect is not mediated by conscious recollection.

  17. Comprehension of a simplified assent form in a vaccine trial for adolescents.

    PubMed

    Lee, Sonia; Kapogiannis, Bill G; Flynn, Patricia M; Rudy, Bret J; Bethel, James; Ahmad, Sushma; Tucker, Diane; Abdalian, Sue Ellen; Hoffman, Dannie; Wilson, Craig M; Cunningham, Coleen K

    2013-06-01

    Future HIV vaccine efficacy trials with adolescents will need to ensure that participants comprehend study concepts in order to confer true informed assent. A Hepatitis B vaccine trial with adolescents offers valuable opportunity to test youth understanding of vaccine trial requirements in general. Youth reviewed a simplified assent form with study investigators and then completed a comprehension questionnaire. Once enrolled, all youth were tested for HIV and confirmed to be HIV-negative. 123 youth completed the questionnaire (mean age=15 years; 63% male; 70% Hispanic). Overall, only 69 (56%) youth answered all six questions correctly. Youth enrolled in a Hepatitis B vaccine trial demonstrated variable comprehension of the study design and various methodological concepts, such as treatment group masking.

  18. Rat Palatability Study for Taste Assessment of Caffeine Citrate Formulation Prepared via Hot-Melt Extrusion Technology

    PubMed Central

    Tiwari, Roshan V.; Polk, Ashley N.; Patil, Hemlata; Ye, Xingyou; Pimparade, Manjeet B.; Repka, Michael A.

    2017-01-01

    Developing a pediatric oral formulation with an age-appropriate dosage form and taste masking of naturally bitter active pharmaceutical ingredients (APIs) are key challenges for formulation scientists. Several techniques are used for taste masking of bitter APIs to improve formulation palatability; however, not all the techniques are applicable to pediatric dosage forms because of the limitations on the kind and concentration of the excipients that can be used. Hot-melt extrusion (HME) technology is used successfully for taste masking of bitter APIs, and overcomes some of the limitations of the existing taste masking techniques. Likewise, analytical taste assessment is an important quality control parameter evaluated by several in vivo and in vitro methods, such as the human taste panel, electrophysiological methods, electronic sensor, and animal preference tests to aid in selecting a taste-masked formulation. However, the most appropriate in-vivo method to assess the taste-masking efficacy of pediatric formulations remains unknown, because it is not known to what extent the human taste panel/electronic tongue can predict the palatability in the pediatric patients. The purpose of this study was to develop taste-masked caffeine citrate extrudates via HME, and to demonstrate the wide applicability of a single bottle-test rat model to record and compare the volume consumed of the taste-masked solutions to that of the pure API. Thus, this rat model can be considered as a low-cost alternative taste-assessment method to the most commonly used expensive human taste panel/electronic tongue method for pediatric formulations. PMID:26573158

  19. Effects of degraded sensory input on memory for speech: behavioral data and a test of biologically constrained computational models.

    PubMed

    Piquado, Tepring; Cousins, Katheryn A Q; Wingfield, Arthur; Miller, Paul

    2010-12-13

    Poor hearing acuity reduces memory for spoken words, even when the words are presented with enough clarity for correct recognition. An "effortful hypothesis" suggests that the perceptual effort needed for recognition draws from resources that would otherwise be available for encoding the word in memory. To assess this hypothesis, we conducted a behavioral task requiring immediate free recall of word-lists, some of which contained an acoustically masked word that was just above perceptual threshold. Results show that masking a word reduces the recall of that word and words prior to it, as well as weakening the linking associations between the masked and prior words. In contrast, recall probabilities of words following the masked word are not affected. To account for this effect we conducted computational simulations testing two classes of models: Associative Linking Models and Short-Term Memory Buffer Models. Only a model that integrated both contextual linking and buffer components matched all of the effects of masking observed in our behavioral data. In this Linking-Buffer Model, the masked word disrupts a short-term memory buffer, causing associative links of words in the buffer to be weakened, affecting memory for the masked word and the word prior to it, while allowing links of words following the masked word to be spared. We suggest that these data account for the so-called "effortful hypothesis", where distorted input has a detrimental impact on prior information stored in short-term memory. Copyright © 2010 Elsevier B.V. All rights reserved.

  20. Comparison of Aerosol Delivery by Face Mask and Tracheostomy Collar.

    PubMed

    Bugis, Alaa A; Sheard, Meryl M; Fink, James B; Harwood, Robert J; Ari, Arzu

    2015-09-01

    The purpose of this study was to compare the performance of a tracheostomy collar, Wright mask, and aerosol mask attached to a jet nebulizer in facilitating aerosolized medication delivery to the lungs. We also compared albuterol delivery with open versus closed fenestration and determined the effect of inspiratory-expiratory ratio (I:E) on aerosol delivery. Albuterol (2.5 mg/3 mL) was administered to an in vitro model consisting of an adult teaching mannequin extrathoracic and upper airway with stoma intubated with an 8-mm fenestrated tracheostomy tube. The cuff was deflated. A collecting filter at the level of the bronchi was connected to a breathing simulator at a tidal volume of 400 mL, breathing frequency of 20 breaths/min, and I:E of 2:1 and 1:2. A jet nebulizer was operated with O2 at 8 L/min. Each interface was tested in triplicate. The flow was discontinued at the end of nebulization. For each test, the nebulizer was attached to a tracheostomy collar with the fenestration open or closed, a Wright mask, or an aerosol mask. Drug was analyzed by spectrophotometry (276 nm). A paired t test and analysis of variance were performed (P < .05). The mean ± SD percent albuterol dose delivered distal to the bronchi was greater with the tracheostomy collar with a closed fenestration (9.4 ± 1.5%) compared with an open fenestration (7.0 ± 0.8%). The doses delivered with the Wright mask (4.1 ± 0.6%) and aerosol mask (3.5 ± 0.04%) were both less than with the tracheostomy collar under either condition (P < .05). Increasing the I:E from 1:2 to 2:1 increased aerosol delivery by 2.5-4%, with significance for the tracheostomy collar with an open fenestration (11.6 ± 1.4%), Wright mask (7.2 ± 0.6%), and aerosol mask (6.1 ± 0.5%). In an adult tracheostomy model, the tracheostomy collar delivered more aerosol to the bronchi than the Wright or aerosol mask. An I:E of 2:1 caused greater aerosol deposition compared with an I:E of 1:2. During aerosol administration via a tracheostomy collar, closing the fenestration improved aerosol delivery. Copyright © 2015 by Daedalus Enterprises.

  1. Benefits of using culturally unfamiliar stimuli in ambiguous emotion identification: A cross-cultural study.

    PubMed

    Koelkebeck, Katja; Kohl, Waldemar; Luettgenau, Julia; Triantafillou, Susanna; Ohrmann, Patricia; Satoh, Shinji; Minoshita, Seiko

    2015-07-30

    A novel emotion recognition task that employs photos of a Japanese mask representing a highly ambiguous stimulus was evaluated. As non-Asians perceive and/or label emotions differently from Asians, we aimed to identify patterns of task-performance in non-Asian healthy volunteers with a view to future patient studies. The Noh mask test was presented to 42 adult German participants. Reaction times and emotion attribution patterns were recorded. To control for emotion identification abilities, a standard emotion recognition task was used among others. Questionnaires assessed personality traits. Finally, results were compared to age- and gender-matched Japanese volunteers. Compared to other tasks, German participants displayed slowest reaction times on the Noh mask test, indicating higher demands of ambiguous emotion recognition. They assigned more positive emotions to the mask than Japanese volunteers, demonstrating culture-dependent emotion identification patterns. As alexithymic and anxious traits were associated with slower reaction times, personality dimensions impacted on performance, as well. We showed an advantage of ambiguous over conventional emotion recognition tasks. Moreover, we determined emotion identification patterns in Western individuals impacted by personality dimensions, suggesting performance differences in clinical samples. Due to its properties, the Noh mask test represents a promising tool in the differential diagnosis of psychiatric disorders, e.g. schizophrenia. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  2. Inheritance of coat colour in the Anatolian shepherd dog.

    PubMed

    Robinson, R

    1989-01-01

    The predominant colour of the Anatolian Shepherd dog varies from a dark fawn to light red, with a variable black muzzle and face (mask). Evidence is presented that the colour is due to the dominant yellow allele (Ay) of the agouti locus. Two other frequent colours are white spotting, due to the piebald allele (sp), and the chinchilla allele (ch). Two rarer colours are the agouti wolf-grey wild type (A+) and a light fawn with a blue facial mask, due to the dilution allele (d).

  3. Geometrical E-beam proximity correction for raster scan systems

    NASA Astrophysics Data System (ADS)

    Belic, Nikola; Eisenmann, Hans; Hartmann, Hans; Waas, Thomas

    1999-04-01

    High pattern fidelity is a basic requirement for the generation of masks containing sub micro structures and for direct writing. Increasing needs mainly emerging from OPC at mask level and x-ray lithography require a correction of the e-beam proximity effect. The most part of e-beam writers are raster scan system. This paper describes a new method for geometrical pattern correction in order to provide a correction solution for e-beam system that are not able to apply variable doses.

  4. [A comparison of various supraglottic airway devices for fiberoptical guided tracheal intubation].

    PubMed

    Metterlein, Thomas; Dintenfelder, Anna; Plank, Christoph; Graf, Bernhard; Roth, Gabriel

    Fiberoptical assisted intubation via placed supraglottic airway devices has been described as safe and easy procedure to manage difficult airways. However visualization of the glottis aperture is essential for fiberoptical assisted intubation. Various different supraglottic airway devices are commercially available and might offer different conditions for fiberoptical assisted intubation. The aim of this study was to compare the best obtainable view of the glottic aperture using different supraglottic airway devices. With approval of the local ethics committee 52 adult patients undergoing elective anesthesia were randomly assigned to a supraglottic airway device (Laryngeal Tube, Laryngeal Mask Airway I-Gel, Laryngeal Mask Airway Unique, Laryngeal Mask Airway Supreme, Laryngeal Mask Airway Aura-once). After standardized induction of anaesthesia the supraglottic airway device was placed according to the manufacturers recommendations. After successful ventilation the position of the supraglottic airway device in regard to the glottic opening was examined with a flexible fiberscope. A fully or partially visible glottic aperture was considered as suitable for fiberoptical assisted intubation. Suitability for fiberoptical assisted intubation was compared between the groups (H-test, U-test; p<0.05). Demographic data was not different between the groups. Placement of the supraglottic airway device and adequate ventilation was successful in all attempts. Glottic view suitable for fiberoptical assisted intubation differed between the devices ranging from 40% for the laringeal tube (LT), 66% for the laryngeal mask airway Supreme, 70% for the Laryngeal Mask Airway I-Gel and 90% for both the Laryngeal Mask Airway Unique and the Laryngeal Mask Airway Aura-once. None of the used supraglottic airway devices offered a full or partial glottic view in all cases. However the Laryngeal Mask Airway Unique and the Laryngeal Mask Airway Aura-once seem to be more suitable for fiberoptical assisted intubation compared to other devices. Copyright © 2016 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  5. A comparison of various supraglottic airway devices for fiberoptical guided tracheal intubation.

    PubMed

    Metterlein, Thomas; Dintenfelder, Anna; Plank, Christoph; Graf, Bernhard; Roth, Gabriel

    Fiberoptical assisted intubation via placed supraglottic airway devices has been described as safe and easy procedure to manage difficult airways. However visualization of the glottis aperture is essential for fiberoptical assisted intubation. Various different supraglottic airway devices are commercially available and might offer different conditions for fiberoptical assisted intubation. The aim of this study was to compare the best obtainable view of the glottic aperture using different supraglottic airway devices. With approval of the local ethics committee 52 adult patients undergoing elective anesthesia were randomly assigned to a supraglottic airway device (Laryngeal Tube, Laryngeal Mask Airway I-Gel, Laryngeal Mask Airway Unique, Laryngeal Mask Airway Supreme, Laryngeal Mask Airway Aura-once). After standardized induction of anesthesia the supraglottic airway device was placed according to the manufacturers recommendations. After successful ventilation the position of the supraglottic airway device in regard to the glottic opening was examined with a flexible fiberscope. A fully or partially visible glottic aperture was considered as suitable for fiberoptical assisted intubation. Suitability for fiberoptical assisted intubation was compared between the groups (H-test, U-test; p<0.05). Demographic data was not different between the groups. Placement of the supraglottic airway device and adequate ventilation was successful in all attempts. Glottic view suitable for fiberoptical assisted intubation differed between the devices ranging from 40% for the laringeal tube (LT), 66% for the laryngeal mask airway Supreme, 70% for the Laryngeal Mask Airway I-Gel and 90% for both the Laryngeal Mask Airway Unique and the Laryngeal Mask Airway Aura-once. None of the used supraglottic airway devices offered a full or partial glottic view in all cases. However the Laryngeal Mask Airway Unique and the Laryngeal Mask Airway Aura-once seem to be more suitable for fiberoptical assisted intubation compared to other devices. Copyright © 2016 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  6. The relationship between masking and short-term consolidation during recall from visual working memory.

    PubMed

    Ricker, Timothy J; Sandry, Joshua

    2018-04-10

    The presentation of a similar but irrelevant stimulus immediately following presentation of a memory item is called masking. Masking is known to reduce performance on working memory tests. This is the type of memory used to hold information in mind for brief periods of time for use in ongoing cognition. Two approaches to understanding masking effects have been proposed in different literatures. Working memory researchers often assume that the reduction in working memory performance after masking is because masking interferes with a transient sensory representation that is needed to complete consolidation into a working memory state. Researchers focused on the attentional blink, a finding that attention cannot be directed to new stimuli during working memory consolidation, have an alternative theory. Attentional blink researchers assume that masking slows the short-term consolidation process, thereby extending the length of the attentional blink. In two experiments, we contrast these two approaches to explaining masking effects and investigate the validity of both hypotheses. Some aspects of both approaches are validated, but neither theoretical perspective alone sufficiently explains the entire pattern of results. © 2018 New York Academy of Sciences.

  7. Application of the unified mask data format based on OASIS for VSB EB writers

    NASA Astrophysics Data System (ADS)

    Suzuki, Toshio; Hirumi, Junji; Suga, Osamu

    2005-11-01

    Mask data preparation (MDP) for modern mask manufacturing becomes a complex process because many kinds of EB data formats are used in mask makers and EB data files continue to become bigger by the application of RET. Therefore we developed a unified mask pattern data format named "OASIS.VSB1" and a job deck format named "MALY2" for Variable-Shaped-Beam (VSB) EB writers. OASIS.VSB is the mask pattern data format based on OASISTM 3 (Open Artwork System Interchange Standard) released as a successive format to GDSII by SEMI. We defined restrictions on OASIS for VSB EB writers to input OASIS.VSB data directly to VSB EB writers just like the native EB data. OASIS.VSB specification and MALY specification have been disclosed to the public and will become a SEMI standard in the near future. We started to promote the spread activities of OASIS.VSB and MALY. For practical use of OASIS.VSB and MALY, we are discussing the infrastructure system of MDP processing using OASIS.VSB and MALY with mask makers, VSB EB makers, and device makers. We are also discussing the tools for the infrastructure system with EDA vendors. The infrastructure system will enable TAT, the man-hour, and the cost in MDP to be reduced. In this paper, we propose the plan of the infrastructure system of MDP processing using OASIS.VSB and MALY as an application of OASIS.VSB and MALY.

  8. Additivity of nonsimultaneous masking for short Gaussian-shaped sinusoids.

    PubMed

    Laback, Bernhard; Balazs, Peter; Necciari, Thibaud; Savel, Sophie; Ystad, Solvi; Meunier, Sabine; Kronland-Martinet, Richard

    2011-02-01

    The additivity of nonsimultaneous masking was studied using Gaussian-shaped tone pulses (referred to as Gaussians) as masker and target stimuli. Combinations of up to four temporally separated Gaussian maskers with an equivalent rectangular bandwidth of 600 Hz and an equivalent rectangular duration of 1.7 ms were tested. Each masker was level-adjusted to produce approximately 8 dB of masking. Excess masking (exceeding linear additivity) was generally stronger than reported in the literature for longer maskers and comparable target levels. A model incorporating a compressive input/output function, followed by a linear summation stage, underestimated excess masking when using an input/output function derived from literature data for longer maskers and comparable target levels. The data could be predicted with a more compressive input/output function. Stronger compression may be explained by assuming that the Gaussian stimuli were too short to evoke the medial olivocochlear reflex (MOCR), whereas for longer maskers tested previously the MOCR caused reduced compression. Overall, the interpretation of the data suggests strong basilar membrane compression for very short stimuli.

  9. READING and FEELING: the effects of a literature-based intervention designed to increase emotional competence in second and third graders

    PubMed Central

    Kumschick, Irina R.; Beck, Luna; Eid, Michael; Witte, Georg; Klann-Delius, Gisela; Heuser, Isabella; Steinlein, Rüdiger; Menninghaus, Winfried

    2014-01-01

    Emotional competence has an important influence on development in school. We hypothesized that reading and discussing children’s books with emotional content increases children’s emotional competence. To examine this assumption, we developed a literature-based intervention, named READING and FEELING, and tested it on 104 second and third graders in their after-school care center. Children who attended the same care center but did not participate in the emotion-centered literary program formed the control group (n = 104). Our goal was to promote emotional competence and to evaluate the effectiveness of the READING and FEELING program. Emotional competence variables were measured prior to the intervention and 9 weeks later, at the end of the program. Results revealed significant improvements in the emotional vocabulary, explicit emotional knowledge, and recognition of masked feelings. Regarding the treatment effect for detecting masked feelings, we found that boys benefited significantly more than girls. These findings underscore the assumption that children’s literature is an appropriate vehicle to support the development of emotional competence in middle childhood. PMID:25566129

  10. Interferometric surface mapping with variable sensitivity.

    PubMed

    Jaerisch, W; Makosch, G

    1978-03-01

    In the photolithographic process, presently employed for the production of integrated circuits, sets of correlated masks are used for exposing the photoresist on silicon wafers. Various sets of masks which are printed in different printing tools must be aligned correctly with respect to the structures produced on the wafer in previous process steps. Even when perfect alignment is considered, displacements and distortions of the printed wafer patterns occur. They are caused by imperfections of the printing tools or/and wafer deformations resulting from high temperature processes. Since the electrical properties of the final integrated circuits and therefore the manufacturing yield depend to a great extent on the precision at which such patterns are superimposed, simple and fast overlay measurements and flatness measurements as well are very important in IC-manufacturing. A simple optical interference method for flatness measurements will be described which can be used under manufacturing conditions. This method permits testing of surface height variations by nearly grazing light incidence by absence of a physical reference plane. It can be applied to polished surfaces and rough surfaces as well.

  11. A randomized, investigator-masked clinical evaluation of the efficacy and safety of clobetasol propionate 0.05% shampoo and tar blend 1% shampoo in the treatment of moderate to severe scalp psoriasis.

    PubMed

    Griffiths, Christopher E M; Finlay, Andrew Y; Fleming, Colin J; Barker, Jonathan N W N; Mizzi, Fabienne; Arsonnaud, Stéphanie

    2006-01-01

    The clinical benefit of currently available tar blend shampoos for the treatment of scalp psoriasis is restricted due to their limited efficacy, low cosmetic appeal and potential for carcinogenicity. This 4-week multicentre, randomized, parallel-group, investigator-masked study included 162 subjects and aimed to compare the efficacy, safety and cosmetic acceptability of clobetasol propionate 0.05% shampoo versus a currently marketed tar blend 1% shampoo in subjects with moderate to severe scalp psoriasis. Clobetasol propionate shampoo was superior to tar blend shampoo with respect to all efficacy variables tested (p<0.001): Total and Global Severity Score; erythema; plaque thickening; desquamation; pruritus; total scalp area involved; and the subject's global assessment of clinical improvement. Both treatments were safe and well-tolerated. Furthermore, more subjects indicated that clobetasol propionate shampoo was more cosmetically acceptable than tar blend shampoo. Clobetasol propionate 0.05% shampoo is a good alternative to tar blend shampoo in the treatment of moderate to severe scalp psoriasis.

  12. Evaluation of visual acuity measurements after autorefraction vs manual refraction in eyes with and without diabetic macular edema.

    PubMed

    Sun, Jennifer K; Qin, Haijing; Aiello, Lloyd Paul; Melia, Michele; Beck, Roy W; Andreoli, Christopher M; Edwards, Paul A; Glassman, Adam R; Pavlica, Michael R

    2012-04-01

    To compare visual acuity (VA) scores after autorefraction vs manual refraction in eyes of patients with diabetes mellitus and a wide range of VAs. The letter score from the Electronic Visual Acuity (EVA) test from the electronic Early Treatment Diabetic Retinopathy Study was measured after autorefraction (AR-EVA score) and after manual refraction (MR-EVA score), which is the research protocol of the Diabetic Retinopathy Clinical Research Network. Testing order was randomized, study participants and VA examiners were masked to refraction source, and a second EVA test using an identical supplemental manual refraction (MR-EVAsuppl score) was performed to determine test-retest variability. In 878 eyes of 456 study participants, the median MR-EVA score was 74 (Snellen equivalent, approximately 20/32). The spherical equivalent was often similar for manual refraction and autorefraction (median difference, 0.00; 5th-95th percentile range, -1.75 to 1.13 diopters). However, on average, the MR-EVA scores were slightly better than the AR-EVA scores, across the entire VA range. Furthermore, the variability between the AR-EVA scores and the MR-EVA scores was substantially greater than the test-retest variability of the MR-EVA scores (P < .001). The variability of differences was highly dependent on the autorefractor model. Across a wide range of VAs at multiple sites using a variety of autorefractors, VA measurements tend to be worse with autorefraction than manual refraction. Differences between individual autorefractor models were identified. However, even among autorefractor models that compare most favorably with manual refraction, VA variability between autorefraction and manual refraction is higher than the test-retest variability of manual refraction. The results suggest that, with current instruments, autorefraction is not an acceptable substitute for manual refraction for most clinical trials with primary outcomes dependent on best-corrected VA.

  13. Simulation-based MDP verification for leading-edge masks

    NASA Astrophysics Data System (ADS)

    Su, Bo; Syrel, Oleg; Pomerantsev, Michael; Hagiwara, Kazuyuki; Pearman, Ryan; Pang, Leo; Fujimara, Aki

    2017-07-01

    For IC design starts below the 20nm technology node, the assist features on photomasks shrink well below 60nm and the printed patterns of those features on masks written by VSB eBeam writers start to show a large deviation from the mask designs. Traditional geometry-based fracturing starts to show large errors for those small features. As a result, other mask data preparation (MDP) methods have become available and adopted, such as rule-based Mask Process Correction (MPC), model-based MPC and eventually model-based MDP. The new MDP methods may place shot edges slightly differently from target to compensate for mask process effects, so that the final patterns on a mask are much closer to the design (which can be viewed as the ideal mask), especially for those assist features. Such an alteration generally produces better masks that are closer to the intended mask design. Traditional XOR-based MDP verification cannot detect problems caused by eBeam effects. Much like model-based OPC verification which became a necessity for OPC a decade ago, we see the same trend in MDP today. Simulation-based MDP verification solution requires a GPU-accelerated computational geometry engine with simulation capabilities. To have a meaningful simulation-based mask check, a good mask process model is needed. The TrueModel® system is a field tested physical mask model developed by D2S. The GPU-accelerated D2S Computational Design Platform (CDP) is used to run simulation-based mask check, as well as model-based MDP. In addition to simulation-based checks such as mask EPE or dose margin, geometry-based rules are also available to detect quality issues such as slivers or CD splits. Dose margin related hotspots can also be detected by setting a correct detection threshold. In this paper, we will demonstrate GPU-acceleration for geometry processing, and give examples of mask check results and performance data. GPU-acceleration is necessary to make simulation-based mask MDP verification acceptable.

  14. Effects of alcohol mixed with energy drink and alcohol alone on subjective intoxication.

    PubMed

    Ulbrich, Andrea; Hemberger, Sophie Helene; Loidl, Alexandra; Dufek, Stephanie; Pablik, Eleonore; Fodor, Sugarka; Herle, Marion; Aufricht, Christoph

    2013-12-01

    Recent studies suggest that the combination of caffeine-containing drinks together with alcohol might reduce the subjective feelings of alcohol intoxication-the so-called "masking effect". In this study, we aimed to review the effects of alcohol in combination with caffeine or energy drink with special focus on the "masking effect". Fifty-two healthy male volunteers were analysed concerning breath alcohol concentration and subjective sensations of intoxication using a 18 item Visual Analogue Scale in a randomised, double-blinded, controlled, four treatments cross-over trial after consumption of (A) placebo, (B) alcohol (vodka 37.5% at a dose of 46.5 g ethanol), (C) alcohol in combination with caffeine at a dose of 80 mg (equivalent to one 250 ml can of energy drink) and (D) alcohol in combination with energy drink at a dose of 250 ml (one can). Primary variables were headache, weakness, salivation and motor coordination. Out of four primary variables, weakness and motor coordination showed a statistically significant difference between alcohol and non-alcohol group, out of 14 secondary variables, five more variables (dizziness, alterations in sight, alterations in walking, agitation and alterations in speech) also showed significant differences due mainly to contrasts with the non-alcohol group. In none of these end points, could a statistically significant effect be found for the additional ingestion of energy drink or caffeine on the subjective feelings of alcohol intoxication. This within-subjects study does not confirm the presence of a "masking effect" when combining caffeine or energy drink with alcohol.

  15. The optical properties of smoke-protective devices.

    DOT National Transportation Integrated Search

    1978-10-01

    Optical properties of 13 smoke-protective devices were determined. The devices tested comprised 8 goggles and 5 fullface oxygen masks (3 rigid one-piece masks and 2 flexible hoods). Those properties evaluated were: (i) light transmission, (ii) optica...

  16. Perception without awareness: further evidence from a Stroop priming task.

    PubMed

    Daza, M Teresa; Ortells, Juan J; Fox, Elaine

    2002-11-01

    In the present research, we examined the influence of prime-target stimulus onset asynchrony (SOA) on Stroop-priming effects from masked words. Participants indicated the color of a central target, which was preceded by a 33-msec prime word followed either immediately or after a variable delay by a pattern mask. The prime word was incongruent or congruent with the target color on 75% and 25% of the trials, respectively. The words followed by an immediate mask produced reliable Stroop interference at SOAs of 300 and 400 msec but not at SOAs of 500 and 700 msec. The words followed by a delayed mask produced a reversed (i.e., facilitatory) Stroop effect, which reached significance at an SOA of 400 msec or longer, but never at the shorter 300-msec SOA. Such an differential time course of both types of Stroop priming effects provides further evidence for the existence of qualitative differences between conscious and nonconscious perceptual processes.

  17. Do different perceptual task sets modulate electrophysiological correlates of masked visuomotor priming? Attention to shape and color put to the test.

    PubMed

    Zovko, Monika; Kiefer, Markus

    2013-02-01

    According to classical theories, automatic processes operate independently of attention. Recent evidence, however, shows that masked visuomotor priming, an example of an automatic process, depends on attention to visual form versus semantics. In a continuation of this approach, we probed feature-specific attention within the perceptual domain and tested in two event-related potential (ERP) studies whether masked visuomotor priming in a shape decision task specifically depends on attentional sensitization of visual pathways for shape in contrast to color. Prior to the masked priming procedure, a shape or a color decision task served to induce corresponding task sets. ERP analyses revealed visuomotor priming effects over the occipitoparietal scalp only after the shape, but not after the color induction task. Thus, top-down control coordinates automatic processing streams in congruency with higher-level goals even at a fine-grained level. Copyright © 2012 Society for Psychophysiological Research.

  18. A backwards glance at words: Using reversed-interior masked primes to test models of visual word identification

    PubMed Central

    Lupker, Stephen J.

    2017-01-01

    The experiments reported here used “Reversed-Interior” (RI) primes (e.g., cetupmor-COMPUTER) in three different masked priming paradigms in order to test between different models of orthographic coding/visual word recognition. The results of Experiment 1, using a standard masked priming methodology, showed no evidence of priming from RI primes, in contrast to the predictions of the Bayesian Reader and LTRS models. By contrast, Experiment 2, using a sandwich priming methodology, showed significant priming from RI primes, in contrast to the predictions of open bigram models, which predict that there should be no orthographic similarity between these primes and their targets. Similar results were obtained in Experiment 3, using a masked prime same-different task. The results of all three experiments are most consistent with the predictions derived from simulations of the Spatial-coding model. PMID:29244824

  19. Masking Release for Igbo and English.

    PubMed

    Ebem, Deborah U; Desloge, Joseph G; Reed, Charlotte M; Braida, Louis D; Uguru, Joy O

    2013-09-01

    In this research, we explored the effect of noise interruption rate on speech intelligibility. Specifically, we used the Hearing In Noise Test (HINT) procedure with the original HINT stimuli (English) and Igbo stimuli to assess speech reception ability in interrupted noise. For a given noise level, the HINT test provides an estimate of the signal-to-noise ratio (SNR) required for 50%-correct speech intelligibility. The SNR for 50%-correct intelligibility changes depending upon the interruption rate of the noise. This phenomenon (called Masking Release) has been studied extensively in English but not for Igbo - which is an African tonal language spoken predominantly in South Eastern Nigeria. This experiment explored and compared the phenomenon of Masking Release for (i) native English speakers listening to English, (ii) native Igbo speakers listening to English, and (iii) native Igbo speakers listening to Igbo. Since Igbo is a tonal language and English is a non-tonal language, this allowed us to compare Masking Release patterns on native speakers of tonal and non-tonal languages. Our results for native English speakers listening to English HINT show that the SNR and the masking release are orderly and consistent with other English HINT data for English speakers. Our result for Igbo speakers listening to English HINT sentences show that there is greater variability in results across the different Igbo listeners than across the English listeners. This result likely reflects different levels of ability in the English language across the Igbo listeners. The masking release values in dB are less than for English listeners. Our results for Igbo speakers listening to Igbo show that in general, the SNRs for Igbo sentences are lower than for English/English and Igbo/English. This means that the Igbo listeners could understand 50% of the Igbo sentences at SNRs less than those required for English sentences by either native or non-native listeners. This result can be explained by the fact that the perception of Igbo utterances by Igbo subjects may have been aided by the prediction of tonal and vowel harmony features existent in the Igbo language. In agreement with other studies, our results also show that in a noisy environment listeners are able to perceive their native language better than a second language. The ability of native language speakers to perceive their language better than a second language in a noisy environment may be attributed to the fact that: Native speakers are more familiar with the sounds of their language than second language speakers.One of the features of language is that it is predictable hence even in noise a native speaker may be able to predict a succeeding word that is scarcely audible. These contextual effects are facilitated by familiarity.

  20. Comparative habitat ecology of Texas and masked bobwhites

    USGS Publications Warehouse

    Guthery, F.S.; King, N.M.; Nolte, K.R.; Kuvlesky, W.P.; DeStefano, S.; Gall, S.A.; Silvy, N.J.

    2000-01-01

    The habitat ecology of masked bobwhites (Colinus virginianus ridgwayi) is poorly understood, which hampers recovery efforts for this endangered bird. During 1994-96, we analyzed the habitat ecology of masked bobwhites in Sonora, Mexico, and Arizona, and compared these findings with the habitat ecology of Texas bobwhites (C. v. texanus) in southern Texas. Mean values for the quantity of low screening cover (<50 cm aboveground), operative temperature (??C), and exposure to aerial predators were relatively constant across regions (CV <14.2%), indicating these variables are important in adaptive habitat-use decisions by bobwhites. Bobwhites exhibited preference in all regions for higher canopy coverage of woody vegetation, lower exposure to aerial predators, and lower operative temperatures in comparison with randomly available conditions. The major habitat deficiencies for masked bobwhites were lack of woody and herbaceous cover, which led to high exposure to aerial predators in Sonora and Arizona. High operative temperatures at quail level were associated with the loss of ???24% of potential habitat space-time in Texas, Sonora, and Arizona. Management to improve habitat for masked bobwhites includes any practice that increases canopy coverage of woody vegetation, and height and coverage of herbaceous vegetation.

  1. Multi-atlas segmentation of the cartilage in knee MR images with sequential volume- and bone-mask-based registrations

    NASA Astrophysics Data System (ADS)

    Lee, Han Sang; Kim, Hyeun A.; Kim, Hyeonjin; Hong, Helen; Yoon, Young Cheol; Kim, Junmo

    2016-03-01

    In spite of its clinical importance in diagnosis of osteoarthritis, segmentation of cartilage in knee MRI remains a challenging task due to its shape variability and low contrast with surrounding soft tissues and synovial fluid. In this paper, we propose a multi-atlas segmentation of cartilage in knee MRI with sequential atlas registrations and locallyweighted voting (LWV). First, bone is segmented by sequential volume- and object-based registrations and LWV. Second, to overcome the shape variability of cartilage, cartilage is segmented by bone-mask-based registration and LWV. In experiments, the proposed method improved the bone segmentation by reducing misclassified bone region, and enhanced the cartilage segmentation by preventing cartilage leakage into surrounding similar intensity region, with the help of sequential registrations and LWV.

  2. Lithographic process window optimization for mask aligner proximity lithography

    NASA Astrophysics Data System (ADS)

    Voelkel, Reinhard; Vogler, Uwe; Bramati, Arianna; Erdmann, Andreas; Ünal, Nezih; Hofmann, Ulrich; Hennemeyer, Marc; Zoberbier, Ralph; Nguyen, David; Brugger, Juergen

    2014-03-01

    We introduce a complete methodology for process window optimization in proximity mask aligner lithography. The commercially available lithography simulation software LAB from GenISys GmbH was used for simulation of light propagation and 3D resist development. The methodology was tested for the practical example of lines and spaces, 5 micron half-pitch, printed in a 1 micron thick layer of AZ® 1512HS1 positive photoresist on a silicon wafer. A SUSS MicroTec MA8 mask aligner, equipped with MO Exposure Optics® was used in simulation and experiment. MO Exposure Optics® is the latest generation of illumination systems for mask aligners. MO Exposure Optics® provides telecentric illumination and excellent light uniformity over the full mask field. MO Exposure Optics® allows the lithography engineer to freely shape the angular spectrum of the illumination light (customized illumination), which is a mandatory requirement for process window optimization. Three different illumination settings have been tested for 0 to 100 micron proximity gap. The results obtained prove, that the introduced process window methodology is a major step forward to obtain more robust processes in mask aligner lithography. The most remarkable outcome of the presented study is that a smaller exposure gap does not automatically lead to better print results in proximity lithography - what the "good instinct" of a lithographer would expect. With more than 5'000 mask aligners installed in research and industry worldwide, the proposed process window methodology might have significant impact on yield improvement and cost saving in industry.

  3. Short-term visual deprivation can enhance spatial release from masking.

    PubMed

    Pagé, Sara; Sharp, Andréanne; Landry, Simon P; Champoux, François

    2016-08-15

    This research aims to study the effect of short-term visual deprivation on spatial release from masking, a major component of the cocktail party effect that allows people to detect an auditory target in noise. The Masking Level Difference (MLD) test was administered on healthy individuals over three sessions: before (I) and after 90min of visual deprivation (II), and after 90min of re-exposure to light (III). A non-deprived control group performed the same tests, but remained sighted between sessions I and II. The non-deprived control group displayed constant results across sessions. However, performance in the MLD test was improved following short-term visual deprivation and performance returned to pre-deprivation values after light re-exposure. This study finds that short-term visual deprivation transiently enhances the spatial release from masking. These data suggest the significant potential for enhancing a process involved in the cocktail party effect in normally developing individuals and adds to an emerging literature on the potential to enhance auditory ability after only a brief period of visual deprivation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  4. Particle protection capability of SEMI-compliant EUV-pod carriers

    NASA Astrophysics Data System (ADS)

    Huang, George; He, Long; Lystad, John; Kielbaso, Tom; Montgomery, Cecilia; Goodwin, Frank

    2010-04-01

    With the projected rollout of pre-production extreme ultraviolet lithography (EUVL) scanners in 2010, EUVL pilot line production will become a reality in wafer fabrication companies. Among EUVL infrastructure items that must be ready, EUV mask carriers remain critical. To keep non-pellicle EUV masks free from particle contamination, an EUV pod concept has been extensively studied. Early prototypes demonstrated nearly particle-free results at a 53 nm PSL equivalent inspection sensitivity during EUVL mask robotic handling, shipment, vacuum pump-purge, and storage. After the passage of SEMI E152, which specifies the EUV pod mechanical interfaces, standards-compliant EUV pod prototypes, including a production version inner pod and prototype outer pod, were built and tested. Their particle protection capability results are reported in this paper. A state-of-the-art blank defect inspection tool was used to quantify their defect protection capability during mask robotic handling, shipment, and storage tests. To ensure the availability of an EUV pod for 2010 pilot production, the progress and preliminary test results of pre-production EUV outer pods are reported as well.

  5. Spatial covert attention increases contrast sensitivity across the CSF: support for signal enhancement

    NASA Technical Reports Server (NTRS)

    Carrasco, M.; Penpeci-Talgar, C.; Eckstein, M.

    2000-01-01

    This study is the first to report the benefits of spatial covert attention on contrast sensitivity in a wide range of spatial frequencies when a target alone was presented in the absence of a local post-mask. We used a peripheral precue (a small circle indicating the target location) to explore the effects of covert spatial attention on contrast sensitivity as assessed by orientation discrimination (Experiments 1-4), detection (Experiments 2 and 3) and localization (Experiment 3) tasks. In all four experiments the target (a Gabor patch ranging in spatial frequency from 0.5 to 10 cpd) was presented alone in one of eight possible locations equidistant from fixation. Contrast sensitivity was consistently higher for peripherally- than for neutrally-cued trials, even though we eliminated variables (distracters, global masks, local masks, and location uncertainty) that are known to contribute to an external noise reduction explanation of attention. When observers were presented with vertical and horizontal Gabor patches an external noise reduction signal detection model accounted for the cueing benefit in a discrimination task (Experiment 1). However, such a model could not account for this benefit when location uncertainty was reduced, either by: (a) Increasing overall performance level (Experiment 2); (b) increasing stimulus contrast to enable fine discriminations of slightly tilted suprathreshold stimuli (Experiment 3); and (c) presenting a local post-mask (Experiment 4). Given that attentional benefits occurred under conditions that exclude all variables predicted by the external noise reduction model, these results support the signal enhancement model of attention.

  6. Automatic Masking for Robust 3D-2D Image Registration in Image-Guided Spine Surgery.

    PubMed

    Ketcha, M D; De Silva, T; Uneri, A; Kleinszig, G; Vogt, S; Wolinsky, J-P; Siewerdsen, J H

    During spinal neurosurgery, patient-specific information, planning, and annotation such as vertebral labels can be mapped from preoperative 3D CT to intraoperative 2D radiographs via image-based 3D-2D registration. Such registration has been shown to provide a potentially valuable means of decision support in target localization as well as quality assurance of the surgical product. However, robust registration can be challenged by mismatch in image content between the preoperative CT and intraoperative radiographs, arising, for example, from anatomical deformation or the presence of surgical tools within the radiograph. In this work, we develop and evaluate methods for automatically mitigating the effect of content mismatch by leveraging the surgical planning data to assign greater weight to anatomical regions known to be reliable for registration and vital to the surgical task while removing problematic regions that are highly deformable or often occluded by surgical tools. We investigated two approaches to assigning variable weight (i.e., "masking") to image content and/or the similarity metric: (1) masking the preoperative 3D CT ("volumetric masking"); and (2) masking within the 2D similarity metric calculation ("projection masking"). The accuracy of registration was evaluated in terms of projection distance error (PDE) in 61 cases selected from an IRB-approved clinical study. The best performing of the masking techniques was found to reduce the rate of gross failure (PDE > 20 mm) from 11.48% to 5.57% in this challenging retrospective data set. These approaches provided robustness to content mismatch and eliminated distinct failure modes of registration. Such improvement was gained without additional workflow and has motivated incorporation of the masking methods within a system under development for prospective clinical studies.

  7. Automatic masking for robust 3D-2D image registration in image-guided spine surgery

    NASA Astrophysics Data System (ADS)

    Ketcha, M. D.; De Silva, T.; Uneri, A.; Kleinszig, G.; Vogt, S.; Wolinsky, J.-P.; Siewerdsen, J. H.

    2016-03-01

    During spinal neurosurgery, patient-specific information, planning, and annotation such as vertebral labels can be mapped from preoperative 3D CT to intraoperative 2D radiographs via image-based 3D-2D registration. Such registration has been shown to provide a potentially valuable means of decision support in target localization as well as quality assurance of the surgical product. However, robust registration can be challenged by mismatch in image content between the preoperative CT and intraoperative radiographs, arising, for example, from anatomical deformation or the presence of surgical tools within the radiograph. In this work, we develop and evaluate methods for automatically mitigating the effect of content mismatch by leveraging the surgical planning data to assign greater weight to anatomical regions known to be reliable for registration and vital to the surgical task while removing problematic regions that are highly deformable or often occluded by surgical tools. We investigated two approaches to assigning variable weight (i.e., "masking") to image content and/or the similarity metric: (1) masking the preoperative 3D CT ("volumetric masking"); and (2) masking within the 2D similarity metric calculation ("projection masking"). The accuracy of registration was evaluated in terms of projection distance error (PDE) in 61 cases selected from an IRB-approved clinical study. The best performing of the masking techniques was found to reduce the rate of gross failure (PDE > 20 mm) from 11.48% to 5.57% in this challenging retrospective data set. These approaches provided robustness to content mismatch and eliminated distinct failure modes of registration. Such improvement was gained without additional workflow and has motivated incorporation of the masking methods within a system under development for prospective clinical studies.

  8. OPC care-area feedforwarding to MPC

    NASA Astrophysics Data System (ADS)

    Dillon, Brian; Peng, Yi-Hsing; Hamaji, Masakazu; Tsunoda, Dai; Muramatsu, Tomoyuki; Ohara, Shuichiro; Zou, Yi; Arnoux, Vincent; Baron, Stanislas; Zhang, Xiaolong

    2016-10-01

    Demand for mask process correction (MPC) is growing for leading-edge process nodes. MPC was originally intended to correct CD linearity for narrow assist features difficult to resolve on a photomask without any correction, but it has been extended to main features as process nodes have been shrinking. As past papers have observed, MPC shows improvements in photomask fidelity. Using advanced shape and dose corrections could give more improvements, especially at line-ends and corners. However, there is a dilemma on using such advanced corrections on full mask level because it increases data volume and run time. In addition, write time on variable shaped beam (VSB) writers also increases as the number of shots increases. Optical proximity correction (OPC) care-area defines circuit design locations that require high mask fidelity under mask writing process variations such as energy fluctuation. It is useful for MPC to switch its correction strategy and permit the use of advanced mask correction techniques in those local care-areas where they provide maximum wafer benefits. The use of mask correction techniques tailored to localized post-OPC design can result in similar desired level of data volume, run time, and write time. ASML Brion and NCS have jointly developed a method to feedforward the care-area information from Tachyon LMC to NDE-MPC to provide real benefit for improving both mask writing and wafer printing quality. This paper explains the detail of OPC care-area feedforwarding to MPC between ASML Brion and NCS, and shows the results. In addition, improvements on mask and wafer simulations are also shown. The results indicate that the worst process variation (PV) bands are reduced up to 37% for a 10nm tech node metal case.

  9. Phase-shifting point diffraction interferometer grating designs

    DOEpatents

    Naulleau, Patrick; Goldberg, Kenneth Alan; Tejnil, Edita

    2001-01-01

    In a phase-shifting point diffraction interferometer, by sending the zeroth-order diffraction to the reference pinhole of the mask and the first-order diffraction to the test beam window of the mask, the test and reference beam intensities can be balanced and the fringe contrast improved. Additionally, using a duty cycle of the diffraction grating other than 50%, the fringe contrast can also be improved.

  10. Aerial image based die-to-model inspections of advanced technology masks

    NASA Astrophysics Data System (ADS)

    Kim, Jun; Lei, Wei-Guo; McCall, Joan; Zaatri, Suheil; Penn, Michael; Nagpal, Rajesh; Faivishevsky, Lev; Ben-Yishai, Michael; Danino, Udy; Tam, Aviram; Dassa, Oded; Balasubramanian, Vivek; Shah, Tejas H.; Wagner, Mark; Mangan, Shmoolik

    2009-10-01

    Die-to-Model (D2M) inspection is an innovative approach to running inspection based on a mask design layout data. The D2M concept takes inspection from the traditional domain of mask pattern to the preferred domain of the wafer aerial image. To achieve this, D2M transforms the mask layout database into a resist plane aerial image, which in turn is compared to the aerial image of the mask, captured by the inspection optics. D2M detection algorithms work similarly to an Aerial D2D (die-to-die) inspection, but instead of comparing a die to another die it is compared to the aerial image model. D2M is used whenever D2D inspection is not practical (e.g., single die) or when a validation of mask conformity to design is needed, i.e., for printed pattern fidelity. D2M is of particular importance for inspection of logic single die masks, where no simplifying assumption of pattern periodicity may be done. The application can tailor the sensitivity to meet the needs at different locations, such as device area, scribe lines and periphery. In this paper we present first test results of the D2M mask inspection application at a mask shop. We describe the methodology of using D2M, and review the practical aspects of the D2M mask inspection.

  11. Across-channel interference in intensity discrimination: The role of practice and listening strategy

    PubMed Central

    Buss, Emily

    2008-01-01

    Pure tone intensity discrimination thresholds can be elevated by the introduction of remote maskers with roved level. This effect is on the order of 10 dB [10log(ΔI/I)] in some conditions and can be demonstrated under conditions of little or no energetic masking. The current study examined the effect of practice and observer strategy on this phenomenon. Experiment 1 included observers who had no formal experience with intensity discrimination and provided training over six hours on a single masked intensity discrimination task to assess learning effects. Thresholds fell with practice for most observers, with significant improvements in 6 out of 8 cases. Despite these improvements significant masking remained in all cases. The second experiment assessed trial-by-trial effects of roved masker level. Conditional probability of a ‘signal-present’ response as a function of the rove value assigned to each of the two masker tones indicates fundamental differences among observers’ processing strategies, even after six hours of practice. The variability in error patterns across practiced listeners suggests that observers approach the task differently, though this variability does not appear to be related to sensitivity. PMID:18177156

  12. Monaural informational masking release in children and adults

    NASA Astrophysics Data System (ADS)

    Buss, Emily; Hall, Joseph W.; Grose, John H.

    2004-05-01

    Informational masking refers to an elevation in signal threshold due to stimulus uncertainty, rather than to energetic masking. This study assessed informational masking and utilization of cues to reduce that masking in children aged 5-9 and adults. We used a manipulation introduced by Kidd et al. [J. Acoust. Soc. Am. 95, 3475-3480 (1994)] in which the signal was a train of eight consecutive tone bursts, each at 1 kHz and 60 ms in duration. Maskers were comprised of a pair of synchronous tone-burst trains whose frequencies were selected from the range spanning 0.2-5 kHz, with a protected region 851-1175 Hz. In the reference condition, where informational masking is pronounced, these maskers were eight bursts and had a fixed frequency within each interval, with new frequencies chosen randomly prior to each interval. Two conditions of masking release were tested: random frequency selection for each masker burst and a masker leading fringe of two additional 60-ms bursts. Both children and adults showed a significant informational masking effect, with children showing a larger effect. Both groups also showed significant release from masking, though initial results suggest that this may have been reduced in the youngest children. [Work supported by NIH, RO1 DC00397.

  13. Attentional capture by masked colour singletons.

    PubMed

    Ansorge, Ulrich; Horstmann, Gernot; Worschech, Franziska

    2010-09-15

    We tested under which conditions a colour singleton of which an observer is unaware captures attention. To prevent visual awareness of the colour singleton, we used backward masking. We find that a masked colour singleton cue captures attention if it matches the observer's goal to search for target colours but not if it is task-irrelevant. This is also reflected in event-related potentials to the visible target: the masked goal-matching cue elicits an attentional potential (N2pc) in a target search task. By contrast, a non-matching but equally strong masked colour singleton cue failed to elicit a capture effect and an N2pc. Results are discussed with regard to currently pertaining conceptions of attentional capture by colour singletons. Copyright 2010 Elsevier Ltd. All rights reserved.

  14. A multicentre phase III randomised controlled single-masked clinical trial evaluating the clinical efficacy and safety of light-masks at preventing dark-adaptation in the treatment of early diabetic macular oedema (CLEOPATRA): study protocol for a randomised controlled trial.

    PubMed

    Sivaprasad, Sobha; Arden, Geoffrey; Prevost, A Toby; Crosby-Nwaobi, Roxanne; Holmes, Helen; Kelly, Joanna; Murphy, Caroline; Rubin, Gary; Vasconcelos, Joanna; Hykin, Philip

    2014-11-22

    This study will evaluate hypoxia, as a novel concept in the pathogenesis of diabetic macular oedema (DMO). As the oxygen demand of the eye is maximum during dark-adaptation, we hypothesize that wearing light-masks during sleep will cause regression and prevent the development and progression of DMO. The study protocol comprises both an efficacy and mechanistic evaluation to test this hypothesis. This is a phase III randomised controlled single-masked multicentre clinical trial to test the clinical efficacy of light-masks at preventing dark-adaptation in the treatment of non-central DMO. Three hundred patients with non-centre-involving DMO in at least one eye will be randomised 1:1 to light-masks and control masks (with no light) to be used during sleep at night for a period of 24 months. The primary outcome is regression of non-central oedema by assessing change in the zone of maximal retinal thickness at baseline on optical coherence tomography (SD-OCT). Secondary outcomes will evaluate the prevention of development and progression of DMO by assessing changes in retinal thickness in different regions of the macula, macular volume, refracted visual acuity and level of retinopathy. Safety parameters will include sleep disturbance. Adverse events and measures of compliance will be assessed over 24 months. Participants recruited to the mechanistic sub-study will have additional retinal oximetry, multifocal electroretinography (ERG) and microperimetry to evaluate the role of hypoxia by assessing and comparing changes induced by supplemental oxygen and the light-masks at 12 months. The outcomes of this study will provide insight into the pathogenesis of DMO and provide evidence on whether a simple, non-invasive device in the form of a light-mask can help prevent the progression to centre-involving DMO and visual impairment in people with diabetes.

  15. Surgical face masks worn by patients with multidrug-resistant tuberculosis: impact on infectivity of air on a hospital ward.

    PubMed

    Dharmadhikari, Ashwin S; Mphahlele, Matsie; Stoltz, Anton; Venter, Kobus; Mathebula, Rirhandzu; Masotla, Thabiso; Lubbe, Willem; Pagano, Marcello; First, Melvin; Jensen, Paul A; van der Walt, Martie; Nardell, Edward A

    2012-05-15

    Drug-resistant tuberculosis transmission in hospitals threatens staff and patient health. Surgical face masks used by patients with tuberculosis (TB) are believed to reduce transmission but have not been rigorously tested. We sought to quantify the efficacy of surgical face masks when worn by patients with multidrug-resistant TB (MDR-TB). Over 3 months, 17 patients with pulmonary MDR-TB occupied an MDR-TB ward in South Africa and wore face masks on alternate days. Ward air was exhausted to two identical chambers, each housing 90 pathogen-free guinea pigs that breathed ward air either when patients wore surgical face masks (intervention group) or when patients did not wear masks (control group). Efficacy was based on differences in guinea pig infections in each chamber. Sixty-nine of 90 control guinea pigs (76.6%; 95% confidence interval [CI], 68-85%) became infected, compared with 36 of 90 intervention guinea pigs (40%; 95% CI, 31-51%), representing a 56% (95% CI, 33-70.5%) decreased risk of TB transmission when patients used masks. Surgical face masks on patients with MDR-TB significantly reduced transmission and offer an adjunct measure for reducing TB transmission from infectious patients.

  16. Comparison of performance of three different types of respiratory protection devices.

    PubMed

    Lawrence, Robert B; Duling, Matthew G; Calvert, Catherine A; Coffey, Christopher C

    2006-09-01

    Respiratory protection is offered to American workers in a variety of ways to guard against potential inhalation hazards. Two of the most common ways are elastomeric N95 respirators and N95 filtering-facepiece respirators. Some in the health care industry feel that surgical masks provide an acceptable level of protection in certain situations against particular hazards. This study compared the performance of these types of respiratory protection during a simulated workplace test that measured both filter penetration and face-seal leakage. A panel of 25 test subjects with varying face sizes tested 15 models of elastomeric N95 respirators, 15 models of N95 filtering-facepiece respirators, and 6 models of surgical masks. Simulated workplace testing was conducted using a TSI PORTACOUNT Plus model 8020, and consisted of a series of seven exercises. Six simulated workplace tests were performed with redonning of the respirator/mask occurring between each test. The results of these tests produced a simulated workplace protection factor (SWPF). The geometric mean (GM) and the 5th percentile values of the SWPFs were computed by category of respiratory protection using the six overall SWPF values. The level of protection provided by each of the three respiratory protection types was compared. The GM and 5th percentile SWPF values without fit testing were used for the comparison, as surgical masks were not intended to be fit tested. The GM values were 36 for elastomeric N95 respirators, 21 for N95 filtering-facepiece respirators, and 3 for surgical masks. An analysis of variance demonstrated a statistically significant difference between all three. Elastomeric N95 respirators had the highest 5th percentile SWPF of 7. N95 filtering-facepiece respirators and surgical masks had 5th percentile SWPFs of 3 and 1, respectively. A Fisher Exact Test revealed that the 5th percentile SWPFs for all three types of respiratory protection were statistically different. In addition, both qualitative (Bitrex and saccharin) and quantitative (N95-Companion) fit testing were performed on the N95 filtering- and elastomeric-facepiece respirators. It was found that passing a fit test generally improves the protection afforded the wearer. Passing the Bitrex fit test resulted in 5th percentile SWPFs of 11.1 and 7.9 for elastomeric and filtering-facepiece respirators, respectively. After passing the saccharin tests, the elastomeric respirators provided a 5th percentile of 11.7, and the filtering-facepiece respirators provided a 5th percentile of 11.0. The 5th percentiles after passing the N95-Companion were 13.0 for the elastomeric respirators and 20.5 for the filtering-facepiece respirators. The data supports fit testing as an essential element of a complete respiratory protection program.

  17. Reticle haze: an industrial approach

    NASA Astrophysics Data System (ADS)

    Gough, Stuart; Gérard, Xavier; Bichebois, Pascal; Roche, Agnès; Sundermann, Frank; Guyader, Véronique; Bièron, Yann; Galvier, Jean; Nicoleau, Serge

    2007-02-01

    Crystal growth on advanced reticles is currently a world wide industrial problem in high end semiconductor production environment, crystals are mainly found on reticles that use high energy photons at 193nm wavelength. The most common crystals to be found on masks are ammonium sulphate, a combination of sulphate, from maskshop residues after clean, pellicle materials and storage conditions and amines from clean room, tool and storage environments. High energy photons act as a catalyst to form crystals on both the pattern side as well as the backglass surface. After a number of exposures crystals can grow in size and eventually become printable. In order to detect HAZE before critical dimensions have been reached suitable detection methods need to be implemented to ensure image integrity. These detection methods are different and complementary depending on the surface to be inspected. Once crystals have started growing, the only method to regain mask quality is to clean the mask at the manufacturers site. This brings with it several undesirable situations, not only is the mask unavailable for production but the cleaning of a mask leads to a potential risk of damaging the mask especially for sub resolution patterns such as scatter bars and phase and transmission changes for eaPSM (Embedded Attenuated Phase Shift Mask) masks. This paper will discuss the initial haze issues seen in a 300mm wafer fab and actions put in place to address the problem. An explanation of results gained from haze reduction actions implemented in a wafer fab will be given. Haze seen by reticle inspection and surface analysis tools can be characterised by typical contamination patterns. These signatures appear after a certain number of wafers exposed depending on several reticle variables such as transmission, Binary, eaPSM, Pellicle. Details will be given of how reticles are managed to ensure minimum impact to a production environment with an appropriate reticle control plan. AMC (Airborne Molecular Contamination) in wafer fab and equipment environment is a key factor for crystal growth. The type of filtration installed to reduce AMC and method of atmospheric monitoring for critical areas will be explained. Choice of reticle storage conditions and materials used for transport during the life of the reticle will be included. Improvements in maskshop cleaning processes, reticle materials and environmental control have lead to extended mask lifetime in the wafer fab of more than 20 times. The fundamental differences and relative monitoring will be described and gain from implemented actions will be presented Once crystals have started growing, the only method to regain mask quality is to clean the mask at the manufacturers site. This brings with it several undesirable situations, not only is the mask unavailable for production but the cleaning of a mask leads to a potential risk of damaging the mask especially for sub resolution patterns such as scatter bars and phase and transmission changes for eaPSM (Embedded Attenuated Phase Shift Mask) masks. This paper will discuss the initial haze issues seen in a 300mm wafer fab and actions put in place to address the problem. An explanation of results gained from haze reduction actions implemented in a wafer fab will be given. Haze seen by reticle inspection and surface analysis tools can be characterised by typical contamination patterns. These signatures appear after a certain number of wafers exposed depending on several reticle variables such as transmission, Binary, eaPSM, Pellicle. Details will be given of how reticles are managed to ensure minimum impact to a production environment with an appropriate reticle control plan. AMC (Airborne Molecular Contamination) in wafer fab and equipment environment is a key factor for crystal growth. The type of filtration installed to reduce AMC and method of atmospheric monitoring for critical areas will be explained. Choice of reticle storage conditions and materials used for transport during the life of the reticle will be included. Improvements in maskshop cleaning processes, reticle materials and environmental control have lead to extended mask lifetime in the wafer fab of more than 20 times. The fundamental differences and relative monitoring will be described and gain from implemented actions will be presented

  18. The Q Continuum: Encounter with the Cloud Mask

    NASA Astrophysics Data System (ADS)

    Ackerman, S. A.; Frey, R.; Holz, R.; Philips, C.; Dutcher, S.

    2017-12-01

    We are developing a common cloud mask for MODIS and VIIRS observations, referred to as the MODIS VIIRS Continuity Mask (MVCM). Our focus is on extending the MODIS-heritage cloud detection approach in order to generate appropriate climate data records for clouds and climate studies. The MVCM is based on heritage from the MODIS cloud mask (MOD35 and MYD35) and employs a series of tests on MODIS reflectances and brightness temperatures. Cloud detection is based on contrasts (i.e., cloud versus background surface) at pixel resolution. The MVCM follows the same approach. These cloud masks use multiple cloud detection tests to indicate the confidence level that the observation is of a clear-sky scene. The outcome of a test ranges from 0 (cloudy) to 1 (clear-sky scene). Because of overlap in the sensitivities of the various spectral tests to the type of cloud, each test is considered in one of several groups. The final cloud mask is determined from the product of the minimum confidence of each group and is referred to as the Q value as defined in Ackerman et al (1998). In MOD35 and MYD35 processing, the Q value is not output, rather predetermined Q values determine the result: If Q ≥ .99 the scene is clear; .95 ≤ Q < .99 the pixel is probably a clear scene, .66 ≤ Q < .95 is probably cloudy and Q < .66 is cloudy. Thus representing Q discretely and not as a continuum. For the MVCM, the numerical value of the Q is output along with the classification of clear, probably clear, probably cloudy, and cloudy. Through comparisons with collocated CALIOP and MODIS observations, we will assess the categorization of the Q values as a function of scene type ). While validation studies have indicated the utility and statistical correctness of the cloud mask approach, the algorithm does not possess immeasurable power and perfection. This comparison will assess the time and space dependence of Q and assure that the laws of physics are followed, at least according to normal human notions. Using CALIOP as representing truth, a receiver operating characteristic curve (ROC) will be analyzed to determine the optimum Q for various scenes and seasons, thus providing a continuum of discriminating thresholds.

  19. Matching OPC and masks on 300-mm lithography tools utilizing variable illumination settings

    NASA Astrophysics Data System (ADS)

    Palitzsch, Katrin; Kubis, Michael; Schroeder, Uwe P.; Schumacher, Karl; Frangen, Andreas

    2004-05-01

    CD control is crucial to maximize product yields on 300mm wafers. This is particularly true for DRAM frontend lithography layers, like gate level, and deep trench (capacitor) level. In the DRAM process, large areas of the chip are taken up by array structures, which are difficult to structure due to aggressive pitch requirements. Consequently, the lithography process is centered such that the array structures are printed on target. Optical proximity correction is applied to print gate level structures in the periphery circuitry on target. Only slight differences of the different Zernike terms can cause rather large variations of the proximity curves, resulting in a difference of isolated and semi-isolated lines printed on different tools. If the deviations are too large, tool specific OPC is needed. The same is true for deep trench level, where the length to width ratio of elongated contact-like structures is an important parameter to adjust the electrical properties of the chip. Again, masks with specific biases for tools with different Zernikes are needed to optimize product yield. Additionally, mask making contributes to the CD variation of the process. Theoretically, the CD deviation caused by an off-centered mask process can easily eat up the majority of the CD budget of a lithography process. In practice, masks are very often distributed intelligently among production tools, such that lens and mask effects cancel each other. However, only dose adjusting and mask allocation may still result in a high CD variation with large systematical contributions. By adjusting the illumination settings, we have successfully implemented a method to reduce CD variation on our advanced processes. Especially inner and outer sigma for annular illumination, and the numerical aperture, can be optimized to match mask and stepper properties. This process will be shown to overcome slight lens and mask differences effectively. The effects on lithography process windows have to be considered, nonetheless.

  20. Fully optimized shaped pupils: preparation for a test at the Subaru Telescope

    NASA Astrophysics Data System (ADS)

    Carlotti, Alexis; Kasdin, N. Jeremy; Martinache, Frantz; Vanderbei, Robert J.; Young, Elizabeth J.; Che, George; Groff, Tyler D.; Guyon, Olivier

    2012-09-01

    The SCExAO instrument at the Subaru telescope, mainly based on a PIAA coronagraph can benefit from the addition of a robust and simple shaped pupil coronagraph. New shaped pupils, fully optimized in 2 dimensions, make it possible to design optimal apodizers for arbitrarily complex apertures, for instance on-axis telescopes such as the Subaru telescope. We have designed several masks with inner working angles as small as 2.5 λ / D, and for high-contrast regions with different shapes. Using Princeton University nanofabrication facilities, we have manufactured two masks by photolithography. These masks have been tested in the laboratory, both in Princeton and in the facilities of the National Astronomical Observatory of Japan (NAOJ) in Hilo. The goal of this work is to prepare tests on the sky of a shaped pupil coronagraph in 2012.

  1. A methodology for testing fault-tolerant software

    NASA Technical Reports Server (NTRS)

    Andrews, D. M.; Mahmood, A.; Mccluskey, E. J.

    1985-01-01

    A methodology for testing fault tolerant software is presented. There are problems associated with testing fault tolerant software because many errors are masked or corrected by voters, limiter, or automatic channel synchronization. This methodology illustrates how the same strategies used for testing fault tolerant hardware can be applied to testing fault tolerant software. For example, one strategy used in testing fault tolerant hardware is to disable the redundancy during testing. A similar testing strategy is proposed for software, namely, to move the major emphasis on testing earlier in the development cycle (before the redundancy is in place) thus reducing the possibility that undetected errors will be masked when limiters and voters are added.

  2. The effectiveness of nasal mask vs face mask ventilation in anesthetized, apneic pediatric subjects over 2 years of age: a randomized controlled trial.

    PubMed

    Itagaki, Taiga; Gubin, Tatyana A; Sayal, Puneet; Jiang, Yandong; Kacmarek, Robert M; Anderson, Thomas Anthony

    2016-02-01

    We hypothesized that anesthetized, apneic children could be ventilated equivalently or more efficiently by nasal mask ventilation (NMV) than face mask ventilation (FMV). The aim of this randomized controlled study was to test this hypothesis by comparing the expiratory tidal volume (Vte) between NMV and FMV. After the induction of anesthesia, 41 subjects, 3-17 years of age without anticipated difficult mask ventilation, were randomly assigned to receive either NMV or FMV with neck extension. Both groups were ventilated with pressure control ventilation (PCV) at 20 cmH2 O of peak inspiratory pressure (PIP) with positive end-expiratory pressure (PEEP) levels of 0, 5, and 10 cmH2 O. An additional mouth closing maneuver (MCM) was applied for the NMV group. The Vte was higher in the FMV group compared with the NMV group (median difference [95% CI]: 8.4 [5.5-11.6] ml·kg(-1) ; P < 0.001) when MCM was not applied. NMV achieved less PEEP than FMV (median difference [95% CI]: 5.0 [4.3-5.3] cmH2 O at 10 cmH2 O; P < 0.001) though both groups achieved the set PIP level. In the NMV group, MCM markedly increased Vte (median increase [95% CI]: 5.9 [2.5-9.0] ml·kg(-1) ; P < 0.005) and PEEP (median increase [95% CI]: 5.0 [0.6-8.6] cmH2 O at 10 cmH2 O; P < 0.005); however, PEEP was highly variable and lower than that of FMV (median difference [95% CI]: 2.5 [0.8-8.5] cmH2 O at 10 cmH2 O; P < 0.05). In anesthetized, apneic children greater than 2 years of age ventilated with an anesthesia ventilator and neck extension, FMV established a greater Vte than NMV regardless of mouth status. NMV could not maintain the set PEEP level due to an air leak from the mouth. The MCM increased the Vte and PEEP. © 2016 John Wiley & Sons Ltd.

  3. Suppression and Contrast Normalization in Motion Processing

    PubMed Central

    2017-01-01

    Sensory neurons are activated by a range of stimuli to which they are said to be tuned. Usually, they are also suppressed by another set of stimuli that have little effect when presented in isolation. The interactions between preferred and suppressive stimuli are often quite complex and vary across neurons, even within a single area, making it difficult to infer their collective effect on behavioral responses mediated by activity across populations of neurons. Here, we investigated this issue by measuring, in human subjects (three males), the suppressive effect of static masks on the ocular following responses induced by moving stimuli. We found a wide range of effects, which depend in a nonlinear and nonseparable manner on the spatial frequency, contrast, and spatial location of both stimulus and mask. Under some conditions, the presence of the mask can be seen as scaling the contrast of the driving stimulus. Under other conditions, the effect is more complex, involving also a direct scaling of the behavioral response. All of this complexity at the behavioral level can be captured by a simple model in which stimulus and mask interact nonlinearly at two stages, one monocular and one binocular. The nature of the interactions is compatible with those observed at the level of single neurons in primates, usually broadly described as divisive normalization, without having to invoke any scaling mechanism. SIGNIFICANCE STATEMENT The response of sensory neurons to their preferred stimulus is often modulated by stimuli that are not effective when presented alone. Individual neurons can exhibit multiple modulatory effects, with considerable variability across neurons even in a single area. Such diversity has made it difficult to infer the impact of these modulatory mechanisms on behavioral responses. Here, we report the effects of a stationary mask on the reflexive eye movements induced by a moving stimulus. A model with two stages, each incorporating a divisive modulatory mechanism, reproduces our experimental results and suggests that qualitative variability of masking effects in cortical neurons might arise from differences in the extent to which such effects are inherited from earlier stages. PMID:29018158

  4. Implementation on Landsat Data of a Simple Cloud Mask Algorithm Developed for MODIS Land Bands

    NASA Technical Reports Server (NTRS)

    Oreopoulos, Lazaros; Wilson, Michael J.; Varnai, Tamas

    2010-01-01

    This letter assesses the performance on Landsat-7 images of a modified version of a cloud masking algorithm originally developed for clear-sky compositing of Moderate Resolution Imaging Spectroradiometer (MODIS) images at northern mid-latitudes. While data from recent Landsat missions include measurements at thermal wavelengths, and such measurements are also planned for the next mission, thermal tests are not included in the suggested algorithm in its present form to maintain greater versatility and ease of use. To evaluate the masking algorithm we take advantage of the availability of manual (visual) cloud masks developed at USGS for the collection of Landsat scenes used here. As part of our evaluation we also include the Automated Cloud Cover Assesment (ACCA) algorithm that includes thermal tests and is used operationally by the Landsat-7 mission to provide scene cloud fractions, but no cloud masks. We show that the suggested algorithm can perform about as well as ACCA both in terms of scene cloud fraction and pixel-level cloud identification. Specifically, we find that the algorithm gives an error of 1.3% for the scene cloud fraction of 156 scenes, and a root mean square error of 7.2%, while it agrees with the manual mask for 93% of the pixels, figures very similar to those from ACCA (1.2%, 7.1%, 93.7%).

  5. Lithography-based automation in the design of program defect masks

    NASA Astrophysics Data System (ADS)

    Vakanas, George P.; Munir, Saghir; Tejnil, Edita; Bald, Daniel J.; Nagpal, Rajesh

    2004-05-01

    In this work, we are reporting on a lithography-based methodology and automation in the design of Program Defect masks (PDM"s). Leading edge technology masks have ever-shrinking primary features and more pronounced model-based secondary features such as optical proximity corrections (OPC), sub-resolution assist features (SRAF"s) and phase-shifted mask (PSM) structures. In order to define defect disposition specifications for critical layers of a technology node, experience alone in deciding worst-case scenarios for the placement of program defects is necessary but may not be sufficient. MEEF calculations initiated from layout pattern data and their integration in a PDM layout flow provide a natural approach for improvements, relevance and accuracy in the placement of programmed defects. This methodology provides closed-loop feedback between layout and hard defect disposition specifications, thereby minimizing engineering test restarts, improving quality and reducing cost of high-end masks. Apart from SEMI and industry standards, best-known methods (BKM"s) in integrated lithographically-based layout methodologies and automation specific to PDM"s are scarce. The contribution of this paper lies in the implementation of Design-For-Test (DFT) principles to a synergistic interaction of CAD Layout and Aerial Image Simulator to drive layout improvements, highlight layout-to-fracture interactions and output accurate program defect placement coordinates to be used by tools in the mask shop.

  6. Validation of masks for determination of V̇O2 max in horses exercising at high intensity.

    PubMed

    Sides, R H; Kirkpatrick, R; Renner, E; Gough, K; Katz, L M; Evans, D L; Bayly, W M

    2018-01-01

    The need for a horse to be ridden while wearing a measurement device that allows unrestricted ventilation and gas exchange has hampered accurate measurement of its maximal oxygen consumption (V̇O 2 max) under field conditions. Design and validate a facemask with the potential to measure V̇O 2 max accurately in the field. Experiment with 6 × 6 Latin square design. Two variations of a mask and associated electronic control module (ECM) were designed to enable breath-by-breath measurement of airflows through two 7.8 cm diameter pneumotachometers located 7.5 cm in front of each narus. The ECM was comprised of an analogue-to-digital converter and a lithium-ion battery that provided power and signal filtering to the pneumotachometers and an oxygen sensing cell, and powered a pump connected to gas sampling ports between the nares and pneumotachometers. Airflow and oxygen content of inspired and expired gases were recorded through the ECM and electronically transferred to a notebook. V̇O 2 was determined from these recordings using a customised software program. Mask B encased the lower jaw. Mask R left the jaw free so the horse could wear a bit if ridden. V̇O 2 max and arterial blood gases were measured in 6 horses during multiple treadmill tests. Each mask was worn twice and results compared to those from an established open flow-through system (O) by ANOVA-RM (P<0.05). System utility was evaluated using the intraclass correlation coefficient of 4 independent raters. Blood gases and V̇O 2 max (151.9±7.0 [mean±s.d.; O], 151.5±9.6 [B], 149.5±7.5 [R] ml/[kg.min]) were not different between masks. V̇O 2 max measures were reproducible for each mask. Intraclass correlation coefficient between raters = 0.99. Some rebreathing of expired air from mask dead space. Masks capable of measuring V̇O 2 max during treadmill exercise were developed, tested and found to be accurate. Mask R has potential application to measurement of V̇O 2 max under field conditions. © 2017 EVJ Ltd.

  7. Inward Leakage Variability between Respirator Fit Test Panels – Part I. Deterministic Approach

    PubMed Central

    Zhuang, Ziqing; Liu, Yuewei; Coffey, Christopher C.; Miller, Colleen; Szalajda, Jonathan

    2015-01-01

    Inter-panel variability has never been investigated. The objective of this study was to determine the variability between different anthropometric panels used to determine the inward leakage (IL) of N95 filtering facepiece respirators (FFRs) and elastomeric half-mask respirators (EHRs). A total of 144 subjects, who were both experienced and non-experienced N95 FFR users, were recruited. Five N95 FFRs and five N95 EHRs were randomly selected from among those models tested previously in our laboratory. The PortaCount Pro+ (without N95-Companion) was used to measure IL of the ambient particles with a detectable size range of 0.02 to 1 μm. The Occupational Safety and Health Administration standard fit test exercises were used for this study. IL test were performed for each subject using each of the 10 respirators. Each respirator/subject combination was tested in duplicate, resulting in a total 20 IL tests for each subject. Three 35-member panels were randomly selected without replacement from the 144 study subjects stratified by the National Institute for Occupational Safety and Health bivariate panel cell for conducting statistical analyses. The geometric mean (GM) IL values for all 10 studied respirators were not significantly different among the three randomly selected 35-member panels. Passing rate was not significantly different among the three panels for all respirators combined or by each model. This was true for all IL pass/fail levels of 1%, 2%, and 5%. Using 26 or more subjects to pass the IL test, all three panels had consistent passing/failing results for pass/fail levels of 1% and 5%. Some disagreement was observed for the 2% pass/fail level. Inter-panel variability exists, but it is small relative to the other sources of variation in fit testing data. The concern about inter-panel variability and other types of variability can be alleviated by properly selecting: pass/fail level (IL 1–5%); panel size (e.g., 25 or 35); and minimum number of subjects required to pass (e.g., 26 of 35 or 23 of 35). PMID:26011282

  8. Distinguishing State Variability From Trait Change in Longitudinal Data: The Role of Measurement (Non)Invariance in Latent State-Trait Analyses

    PubMed Central

    Geiser, Christian; Keller, Brian T.; Lockhart, Ginger; Eid, Michael; Cole, David A.; Koch, Tobias

    2014-01-01

    Researchers analyzing longitudinal data often want to find out whether the process they study is characterized by (1) short-term state variability, (2) long-term trait change, or (3) a combination of state variability and trait change. Classical latent state-trait (LST) models are designed to measure reversible state variability around a fixed set-point or trait, whereas latent growth curve (LGC) models focus on long-lasting and often irreversible trait changes. In the present paper, we contrast LST and LGC models from the perspective of measurement invariance (MI) testing. We show that establishing a pure state-variability process requires (a) the inclusion of a mean structure and (b) establishing strong factorial invariance in LST analyses. Analytical derivations and simulations demonstrate that LST models with non-invariant parameters can mask the fact that a trait-change or hybrid process has generated the data. Furthermore, the inappropriate application of LST models to trait change or hybrid data can lead to bias in the estimates of consistency and occasion-specificity, which are typically of key interest in LST analyses. Four tips for the proper application of LST models are provided. PMID:24652650

  9. A mask manufacturer's perspective on maskless lithography

    NASA Astrophysics Data System (ADS)

    Buck, Peter; Biechler, Charles; Kalk, Franklin

    2005-11-01

    Maskless Lithography (ML2) is again being considered for use in mainstream CMOS IC manufacturing. Sessions at technical conferences are being devoted to ML2. A multitude of new companies have been formed in the last several years to apply new concepts to breaking the throughput barrier that has in the past prevented ML2 from achieving the cost and cycle time performance necessary to become economically viable, except in rare cases. Has Maskless Lithography's (we used to call it "Direct Write Lithography") time really come? If so, what is the expected impact on the mask manufacturer and does it matter? The lithography tools used today in mask manufacturing are similar in concept to ML2 except for scale, both in throughput and feature size. These mask tools produce highly accurate lithographic images directly from electronic pattern files, perform multi-layer overlay, and mix-n-match across multiple tools, tool types and sites. Mask manufacturers are already accustomed to the ultimate low volume - one substrate per design layer. In order to achieve the economically required throughput, proposed ML2 systems eliminate or greatly reduce some of the functions that are the source of the mask writer's accuracy. Can these ML2 systems meet the demanding lithographic requirements without these functions? ML2 may eliminate the reticle but many of the processes and procedures performed today by the mask manufacturer are still required. Examples include the increasingly complex mask data preparation step and the verification performed to ensure that the pattern on the reticle is accurately representing the design intent. The error sources that are fixed on a reticle are variable with time on an ML2 system. It has been proposed that if ML2 is successful it will become uneconomical to be in the mask business - that ML2, by taking the high profit masks will take all profitability out of mask manufacturing and thereby endanger the entire semiconductor industry. Others suggest that a successful ML2 system solves the mask cost issue and thereby reduces the need and attractiveness of ML2. Are these concerns valid? In this paper we will present a perspective on maskless lithography from the considerable "direct write" experience of a mask manufacturer. We will examine the various business models proposed for ML2 insertion as well as the key technical challenges to achieving simultaneously the throughput and the lithographic quality necessary to become economically viable. We will consider the question of the economic viability of the mask industry in a post-ML2 world and will propose possible models where the mask industry can meaningfully participate.

  10. Forward Masking of the Speech-Evoked Auditory Brainstem Response.

    PubMed

    Hodge, Sarah E; Menezes, Denise C; Brown, Kevin D; Grose, John H

    2018-02-01

    The hypothesis tested was that forward masking of the speech-evoked auditory brainstem response (sABR) increases peak latency as an inverse function of masker-signal interval (Δt), and that the overall persistence of forward masking is age dependent. Older listeners exhibit deficits in forward masking. If forward-masked sABRs provide an objective measure of the susceptibility of speech sounds to prior stimulation, then this provides a novel approach to examining the age dependence of temporal processing. A /da/ stimulus forward masked by speech-shaped noise (Δt = 4-64 ms) was used to measure sABRs in 10 younger and nine older participants. Forward masking of subsegments of the /da/ stimulus (Δt = 16 ms) and click trains (Δt = 0-64 ms) was also measured. Forward-masked sABRs from young participants showed an increase in latency with decreasing Δt for the initial peak. Latency shifts for later peaks were smaller and more uniform. None of the peak latencies returned to baseline by Δt = 64 ms. Forward-masked /da/ subsegments showed peak latency shifts that did not depend simply on peak position, while forward-masked click trains showed latency shifts that were dependent on click position. The sABRs from older adults were less robust but confirmed the viability of the approach. Forward masking of the sABR provides an objective measure of the susceptibility of the auditory system to prior stimulation. Failure of recovery functions to return to baseline suggests an interaction between forward masking by the prior masker and temporal effects within the stimulus itself.

  11. Simple method for generating adjustable trains of picosecond electron bunches

    NASA Astrophysics Data System (ADS)

    Muggli, P.; Allen, B.; Yakimenko, V. E.; Park, J.; Babzien, M.; Kusche, K. P.; Kimura, W. D.

    2010-05-01

    A simple, passive method for producing an adjustable train of picosecond electron bunches is demonstrated. The key component of this method is an electron beam mask consisting of an array of parallel wires that selectively spoils the beam emittance. This mask is positioned in a high magnetic dispersion, low beta-function region of the beam line. The incoming electron beam striking the mask has a time/energy correlation that corresponds to a time/position correlation at the mask location. The mask pattern is transformed into a time pattern or train of bunches when the dispersion is brought back to zero downstream of the mask. Results are presented of a proof-of-principle experiment demonstrating this novel technique that was performed at the Brookhaven National Laboratory Accelerator Test Facility. This technique allows for easy tailoring of the bunch train for a particular application, including varying the bunch width and spacing, and enabling the generation of a trailing witness bunch.

  12. Overlay improvement by exposure map based mask registration optimization

    NASA Astrophysics Data System (ADS)

    Shi, Irene; Guo, Eric; Chen, Ming; Lu, Max; Li, Gordon; Li, Rivan; Tian, Eric

    2015-03-01

    Along with the increased miniaturization of semiconductor electronic devices, the design rules of advanced semiconductor devices shrink dramatically. [1] One of the main challenges of lithography step is the layer-to-layer overlay control. Furthermore, DPT (Double Patterning Technology) has been adapted for the advanced technology node like 28nm and 14nm, corresponding overlay budget becomes even tighter. [2][3] After the in-die mask registration (pattern placement) measurement is introduced, with the model analysis of a KLA SOV (sources of variation) tool, it's observed that registration difference between masks is a significant error source of wafer layer-to-layer overlay at 28nm process. [4][5] Mask registration optimization would highly improve wafer overlay performance accordingly. It was reported that a laser based registration control (RegC) process could be applied after the pattern generation or after pellicle mounting and allowed fine tuning of the mask registration. [6] In this paper we propose a novel method of mask registration correction, which can be applied before mask writing based on mask exposure map, considering the factors of mask chip layout, writing sequence, and pattern density distribution. Our experiment data show if pattern density on the mask keeps at a low level, in-die mask registration residue error in 3sigma could be always under 5nm whatever blank type and related writer POSCOR (position correction) file was applied; it proves random error induced by material or equipment would occupy relatively fixed error budget as an error source of mask registration. On the real production, comparing the mask registration difference through critical production layers, it could be revealed that registration residue error of line space layers with higher pattern density is always much larger than the one of contact hole layers with lower pattern density. Additionally, the mask registration difference between layers with similar pattern density could also achieve under 5nm performance. We assume mask registration excluding random error is mostly induced by charge accumulation during mask writing, which may be calculated from surrounding exposed pattern density. Multi-loading test mask registration result shows that with x direction writing sequence, mask registration behavior in x direction is mainly related to sequence direction, but mask registration in y direction would be highly impacted by pattern density distribution map. It proves part of mask registration error is due to charge issue from nearby environment. If exposure sequence is chip by chip for normal multi chip layout case, mask registration of both x and y direction would be impacted analogously, which has also been proved by real data. Therefore, we try to set up a simple model to predict the mask registration error based on mask exposure map, and correct it with the given POSCOR (position correction) file for advanced mask writing if needed.

  13. The effect of massage on heart rate variability in preterm infants.

    PubMed

    Smith, S L; Lux, R; Haley, S; Slater, H; Beachy, J; Beechy, J; Moyer-Mileur, L J

    2013-01-01

    To test the hypothesis that massage would improve autonomic nervous system (ANS) function as measured by heart rate variability (HRV) in preterm infants. Medically stable, 29- to 32-week preterm infants (17 massage, 20 control) were enrolled in a masked, randomized longitudinal study. Licensed massage therapists provided the massage or control condition twice a day for 4 weeks. Weekly HRV, a measure of ANS development and function, was analyzed using SPSS generalized estimating equations. Infant characteristics were similar between groups. HRV improved in massaged infants but not in the control infants (P<0.05). Massaged males had a greater improvement in HRV than females (P<0.05). HRV in massaged infants was on a trajectory comparable to term-born infants by study completion. Massage-improved HRV in a homogeneous sample of hospitalized, medically stable, preterm male infants and may improve infant response to exogenous stressors. We speculate that massage improves ANS function in these infants.

  14. Proximity Effect Correction by Pattern Modified Stencil Mask in Large-Field Projection Electron-Beam Lithography

    NASA Astrophysics Data System (ADS)

    Kobinata, Hideo; Yamashita, Hiroshi; Nomura, Eiichi; Nakajima, Ken; Kuroki, Yukinori

    1998-12-01

    A new method for proximity effect correction, suitable for large-field electron-beam (EB) projection lithography with high accelerating voltage, such as SCALPEL and PREVAIL in the case where a stencil mask is used, is discussed. In this lithography, a large-field is exposed by the same dose, and thus, the dose modification method, which is used in the variable-shaped beam and the cell projection methods, cannot be used in this case. In this study, we report on development of a new proximity effect correction method which uses a pattern modified stencil mask suitable for high accelerating voltage and large-field EB projection lithography. In order to obtain the mask bias value, we have investigated linewidth reduction, due to the proximity effect, in the peripheral memory cell area, and found that it could be expressed by a simple function and all the correction parameters were easily determined from only the mask pattern data. The proximity effect for the peripheral array pattern could also be corrected by considering the pattern density. Calculated linewidth deviation was 3% or less for a 0.07-µm-L/S memory cell pattern and 5% or less for a 0.14-µm-line and 0.42-µm-space peripheral array pattern, simultaneously.

  15. Deformably registering and annotating whole CLARITY brains to an atlas via masked LDDMM

    NASA Astrophysics Data System (ADS)

    Kutten, Kwame S.; Vogelstein, Joshua T.; Charon, Nicolas; Ye, Li; Deisseroth, Karl; Miller, Michael I.

    2016-04-01

    The CLARITY method renders brains optically transparent to enable high-resolution imaging in the structurally intact brain. Anatomically annotating CLARITY brains is necessary for discovering which regions contain signals of interest. Manually annotating whole-brain, terabyte CLARITY images is difficult, time-consuming, subjective, and error-prone. Automatically registering CLARITY images to a pre-annotated brain atlas offers a solution, but is difficult for several reasons. Removal of the brain from the skull and subsequent storage and processing cause variable non-rigid deformations, thus compounding inter-subject anatomical variability. Additionally, the signal in CLARITY images arises from various biochemical contrast agents which only sparsely label brain structures. This sparse labeling challenges the most commonly used registration algorithms that need to match image histogram statistics to the more densely labeled histological brain atlases. The standard method is a multiscale Mutual Information B-spline algorithm that dynamically generates an average template as an intermediate registration target. We determined that this method performs poorly when registering CLARITY brains to the Allen Institute's Mouse Reference Atlas (ARA), because the image histogram statistics are poorly matched. Therefore, we developed a method (Mask-LDDMM) for registering CLARITY images, that automatically finds the brain boundary and learns the optimal deformation between the brain and atlas masks. Using Mask-LDDMM without an average template provided better results than the standard approach when registering CLARITY brains to the ARA. The LDDMM pipelines developed here provide a fast automated way to anatomically annotate CLARITY images; our code is available as open source software at http://NeuroData.io.

  16. Resist heating effect on e-beam mask writing at 75 kV and 60 A/cm2

    NASA Astrophysics Data System (ADS)

    Benes, Zdenek; Deverich, Christina; Huang, Chester; Lawliss, Mark

    2003-12-01

    Resist heating has been known to be one of the main contributors to local CD variation in mask patterning using variable shape e-beam tools. Increasingly complex mask patterns require increased number of shapes which drives the need for higher electron beam current densities to maintain reasonable write times. As beam current density is increased, CD error resulting from resist heating may become a dominating contributor to local CD variations. In this experimental study, the IBM EL4+ mask writer with high voltage and high current density has been used to quantitatively investigate the effect of resist heating on the local CD uniformity. ZEP 7000 and several chemically amplified resists have been evaluated under various exposure conditions (single-pass, multi-pass, variable spot size) and pattern densities. Patterns were designed specifically to allow easy measurement of local CD variations with write strategies designed to maximize the effect of resist heating. Local CD variations as high as 15 nm in 18.75 × 18.75 μm sub-field size have been observed for ZEP 7000 in a single-pass writing with full 1000 nm spots at 50% pattern density. This number can be reduced by increasing the number of passes or by decreasing the maximum spot size. The local CD variation has been reduced to as low as 2 nm for ZEP 7000 for the same pattern under modified exposure conditions. The effectiveness of various writing strategies is discussed as well as their possible deficiencies. Minimal or no resist heating effects have been observed for the chemically amplified resists studied. The results suggest that the resist heating effect can be well controlled by careful selection of the resist/process system and/or writing strategy and that resist heating does not have to pose a problem for high throughput e-beam mask making that requires high voltage and high current densities.

  17. Hot spot variability and lithography process window investigation by CDU improvement using CDC technique

    NASA Astrophysics Data System (ADS)

    Thamm, Thomas; Geh, Bernd; Djordjevic Kaufmann, Marija; Seltmann, Rolf; Bitensky, Alla; Sczyrba, Martin; Samy, Aravind Narayana

    2018-03-01

    Within the current paper, we will concentrate on the well-known CDC technique from Carl Zeiss to improve the CD distribution of the wafer by improving the reticle CDU and its impact on hotspots and Litho process window. The CDC technique uses an ultra-short pulse laser technology, which generates a micro-level Shade-In-Element (also known as "Pixels") into the mask quartz bulk material. These scatter centers are able to selectively attenuate certain areas of the reticle in higher resolution compared to other methods and thus improve the CD uniformity. In a first section, we compare the CDC technique with scanner dose correction schemes. It becomes obvious, that the CDC technique has unique advantages with respect to spatial resolution and intra-field flexibility over scanner correction schemes, however, due to the scanner flexibility across wafer both methods are rather complementary than competing. In a second section we show that a reference feature based correction scheme can be used to improve the CDU of a full chip with multiple different features that have different MEEF and dose sensitivities. In detail we will discuss the impact of forward scattering light originated by the CDC pixels on the illumination source and the related proximity signature. We will show that the impact on proximity is small compared to the CDU benefit of the CDC technique. Finally we show to which extend the reduced variability across reticle will result in a better common electrical process window of a whole chip design on the whole reticle field on wafer. Finally we will discuss electrical verification results between masks with purposely made bad CDU that got repaired by the CDC technique versus inherently good "golden" masks on a complex logic device. No yield difference is observed between the repaired bad masks and the masks with good CDU.

  18. Phase-shifting point diffraction interferometer focus-aid enhanced mask

    DOEpatents

    Naulleau, Patrick

    2000-01-01

    A phase-shifting point diffraction interferometer system (PS/PDI) employing a PS/PDI mask that includes a PDI focus aid is provided. The PDI focus aid mask includes a large or secondary reference pinhole that is slightly displaced from the true or primary reference pinhole. The secondary pinhole provides a larger capture tolerance for interferometrically performing fine focus. With the focus-aid enhanced mask, conventional methods such as the knife-edge test can be used to perform an initial (or rough) focus and the secondary (large) pinhole is used to perform interferometric fine focus. Once the system is well focused, high accuracy interferometry can be performed using the primary (small) pinhole.

  19. Do little interactions get lost in dark random forests?

    PubMed

    Wright, Marvin N; Ziegler, Andreas; König, Inke R

    2016-03-31

    Random forests have often been claimed to uncover interaction effects. However, if and how interaction effects can be differentiated from marginal effects remains unclear. In extensive simulation studies, we investigate whether random forest variable importance measures capture or detect gene-gene interactions. With capturing interactions, we define the ability to identify a variable that acts through an interaction with another one, while detection is the ability to identify an interaction effect as such. Of the single importance measures, the Gini importance captured interaction effects in most of the simulated scenarios, however, they were masked by marginal effects in other variables. With the permutation importance, the proportion of captured interactions was lower in all cases. Pairwise importance measures performed about equal, with a slight advantage for the joint variable importance method. However, the overall fraction of detected interactions was low. In almost all scenarios the detection fraction in a model with only marginal effects was larger than in a model with an interaction effect only. Random forests are generally capable of capturing gene-gene interactions, but current variable importance measures are unable to detect them as interactions. In most of the cases, interactions are masked by marginal effects and interactions cannot be differentiated from marginal effects. Consequently, caution is warranted when claiming that random forests uncover interactions.

  20. Surgical Face Masks Worn by Patients with Multidrug-Resistant Tuberculosis

    PubMed Central

    Mphahlele, Matsie; Stoltz, Anton; Venter, Kobus; Mathebula, Rirhandzu; Masotla, Thabiso; Lubbe, Willem; Pagano, Marcello; First, Melvin; Jensen, Paul A.; van der Walt, Martie; Nardell, Edward A.

    2012-01-01

    Rationale: Drug-resistant tuberculosis transmission in hospitals threatens staff and patient health. Surgical face masks used by patients with tuberculosis (TB) are believed to reduce transmission but have not been rigorously tested. Objectives: We sought to quantify the efficacy of surgical face masks when worn by patients with multidrug-resistant TB (MDR-TB). Methods: Over 3 months, 17 patients with pulmonary MDR-TB occupied an MDR-TB ward in South Africa and wore face masks on alternate days. Ward air was exhausted to two identical chambers, each housing 90 pathogen-free guinea pigs that breathed ward air either when patients wore surgical face masks (intervention group) or when patients did not wear masks (control group). Efficacy was based on differences in guinea pig infections in each chamber. Measurements and Main Results: Sixty-nine of 90 control guinea pigs (76.6%; 95% confidence interval [CI], 68–85%) became infected, compared with 36 of 90 intervention guinea pigs (40%; 95% CI, 31–51%), representing a 56% (95% CI, 33–70.5%) decreased risk of TB transmission when patients used masks. Conclusions: Surgical face masks on patients with MDR-TB significantly reduced transmission and offer an adjunct measure for reducing TB transmission from infectious patients. PMID:22323300

  1. Bitter taste masking of enzyme-treated soy protein in water and bread.

    PubMed

    Bertelsen, Anne S; Laursen, Anne; Knudsen, Tine A; Møller, Stine; Kidmose, Ulla

    2018-08-01

    Bioactive protein hydrolysates are often very bitter. To overcome this challenge, xylitol, sucrose, α-cyclodextrin, maltodextrin and combinations of these were tested systematically as bitter-masking agents of an enzyme-treated soy protein in an aqueous model and in a bread model. Sensory descriptive analysis was used to reveal the bitter-masking effect of the taste-masking blends on the enzyme-treated soy protein. In water, xylitol, sucrose and maltodextrin reduced bitterness significantly, whereas α-cyclodextrin did not. No significant difference was observed in bitterness reduction between xylitol and sucrose. Both reduced bitterness significantly more than maltodextrin. No interactions between the taste-masking agents affecting bitterness reduction were found. Clearer bitter-masking effects were seen in the aqueous model compared with the bread model. The bitter-masking effects of α-cyclodextrin and maltodextrin were similar between water and bread. The effect of xylitol and sucrose on bitterness suppression varied between the systems. In water, bitterness was negatively correlated with sweetness. In bread, bitterness was negatively correlated with freshness, and maltodextrin significantly reduced bitterness of the enzyme-treated soy protein and increased freshness. Bitter-masking effects were generally more discernible in the aqueous model compared with the bread model. © 2018 Society of Chemical Industry. © 2018 Society of Chemical Industry.

  2. Dual-echo EPI for non-equilibrium fMRI - implications of different echo combinations and masking procedures.

    PubMed

    Beissner, Florian; Baudrexel, Simon; Volz, Steffen; Deichmann, Ralf

    2010-08-15

    Dual-echo EPI is based on the acquisition of two images with different echo times per excitation, thus allowing for the calculation of purely T2(*) weighted data. The technique can be used for the measurement of functional activation whenever the prerequisite of constant equilibrium magnetization cannot be fulfilled due to variable inter-volume delays. The latter is the case when image acquisition is triggered by physiological parameters (e.g. cardiac gating) or by the subject's response. Despite its frequent application, there is currently no standardized way of combining the information obtained from the two acquired echoes. The goal of this study was to quantify the implication of different echo combination methods (quotients of echoes and quantification of T(2)(*)) and calculation modalities, either pre-smoothing data before combination or subjecting unsmoothed combined data to masking (no masking, volume-wise masking, joint masking), on the theoretically predicted signal-to-noise ratio (SNR) of the BOLD response and on activation results of two fMRI experiments using finger tapping and visual stimulation in one group (n=5) and different motor paradigms to activate motor areas in the cortex and the brainstem in another group (n=21). A significant impact of echo combination and masking procedure was found for both SNR and activation results. The recommended choice is a direct calculation of T(2)(*) values, either using joint masking on unsmoothed data, or pre-smoothing images prior to T(2)(*) calculation. This method was most beneficial in areas close to the surface of the brain or adjacent to the ventricles and may be especially relevant to brainstem fMRI. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  3. Current status of x-ray mask manufacturing at the Microlithographic Mask Development Center

    NASA Astrophysics Data System (ADS)

    Kimmel, Kurt R.; Hughes, Patrick J.

    1996-07-01

    The Microlithographic Mask Development Center (MMD) has been the focal point of X-ray mask development efforts in the United States since its inception in 1993. Funded by the Advanced Research Projects Agency (ARPA), and with technical support from the Proximity X-ray Lithography Association (AT&T, IBM, Loral Federal Systems, and Motorola) the MMD has recently made dramatic advances in mask fabrication. Numerous defect-free 64Mb and 256Mb DRAM masks have been made on both boron-doped silicon and silicon carbide substrates. Image-placement error of less than 35nm 3 sigma is achieved with high yield. Image-size (critical dimension) control of 25nm 3 sigma on 250nm nominal images is representative performance. This progress is being made in a manufacturing environment with significant volumes, multiple customers, multiple substrate configurations, and fast turnaround-time (TAT) requirements. The MMD state-of-the-art equipment infrastructure has made much of this progress possible. This year the MMD qualified the EL-4, an IBM-designed-and-built variable-shaped-spot e-beam system. The fundamental performance parameters of this system will be described. Operational techniques of multiple partial exposure writing and product specific emulation (PSE) have been implemented to improve image-placement accuracy with remarkable success. Image-size control was studied in detail with contributory components separated. Defect density was systematically reduced to yield defect-free masks while simultaneously tightening inspection criteria. Information about these and other recent engineering highlights will be reported. An outline of the primary engineering challenges and goals for 1996 and status of progress toward 100 nm design rule capability will also be given.

  4. Emulating JWST/NIRCam Exoplanet Transit Observations in a Testbed laboratory experiment

    NASA Astrophysics Data System (ADS)

    Touli-Lebreton, D.; Vasisht, G.; Smith, R.; Krist, J.; Beichman, C.

    2014-03-01

    The transit technique is used for the detection and characterization of exoplanets. The combination of a transit measurement with a radial velocity measurement gives information about a planet's radius and mass, respectively, leading to an estimate of the planet's density and therefore to its composition and evolutionary history. Spectroscopic observations of individual planets have revealed atomic and molecular species such as H2O, CO2 and CH4 in atmospheres of planets orbiting bright stars, e.g. Deming et al 2013. These transit observations require extremely precise photometry. For instance, Jupiter transit results to a 1% brightness decrease of a solar type star while the Earth causes only a 0.0084% decrease (84 ppm). In our controlled laboratory experiment, we use a H2RG detector, two lamps of variable intensity, along with spectral line and photometric simulation masks to emulate the signals from a star-only, from a planet-only and finally, from a combination of a planet + star. Two masks have been used to simulate spectra in monochromatic light. The masks are 1040 pixels in length with one mask having a 2-pixel width and the other a 10-pixel width. From many-hour long observing sequences we obtain time series photometry with deliberate offsets introduced to test sensitivity to pointing jitter and other effects. We can modify the star- planet brightness contrast by factors up to 104:1. With cross correlation techniques we calculate positional shifts which are then used to decorrelate the effects of vertical and lateral offsets due to turbulence and instrumental vibrations on the photometry. Using Principal Component Analysis (PCA), we reject correlated temporal noise to achieve a precision lower than 50 ppm (Clanton et al 2012). Testbed experiments are ongoing to provide quantitative information on the achievable spectroscopic precision using realistic exoplanet spectra with the goal to define optimized data acquisition sequences for use, for example, with the James Webb Space Telescope.

  5. Preparation of sildenafil citrate microcapsules and in vitro/in vivo evaluation of taste masking efficiency.

    PubMed

    Yi, Eun-Jin; Kim, Ju-Young; Rhee, Yun-Seok; Kim, Su-Hyeon; Lee, Hyo-Joong; Park, Chun-Woong; Park, Eun-Seok

    2014-05-15

    The aim of the present study was to prepare the particulate taste-masking system to mask the bitter taste of sildenafil citrate (SC), a well-known phosphodiesterase-5 inhibitor used for erectile dysfunction (ED) and pulmonary artery hypertension (PAH). It was evaluated for the taste masking efficiency by the in vitro measurement using electronic tongue (e-tongue) system and the in vivo human panel sensory test. Microcapsules were prepared by microencapsulation with a gastro-soluble polymer, Eudragit(®) E100 (E100), using a spray drying technique at four different weight ratios (2:1, 1:1, 1:2, and 1:3). Characters of prepared microcapsules and the effect of polymer ratio on the taste masking were investigated. The particle morphology and the distribution of SC in microcapsules were observed by SEM-EDS and physical properties were evaluated by PXRD, Raman spectroscopy, and DSC. By drug dissolution studies at pH 1.2 buffer and DW, it was found that E100 was not able to alter the drug release in stomach. As the result of taste evaluation studies, there were a good correlation (R(2)=0.9867) between the weight ratio of polymer and the taste masking efficiency expressed in the distances on the PCA map of the e-tongue data, and a relevance of the e-tongue measurement with the result of sensory test. Copyright © 2014. Published by Elsevier B.V.

  6. Hybrid shearing and phase-shifting point diffraction interferometer

    DOEpatents

    Goldberg, Kenneth Alan; Naulleau, Patrick P.

    2003-06-03

    A new interferometry configuration combines the strengths of two existing interferometry methods, improving the quality and extending the dynamic range of both. On the same patterned mask, placed near the image-plane of an optical system under test, patterns for phase-shifting point diffraction interferometry and lateral shearing interferometry coexist. The former giving verifiable high accuracy for the measurement of nearly diffraction-limited optical systems. The latter enabling the measurement of optical systems with more than one wave of aberration in the system wavefront. The interferometry configuration is a hybrid shearing and point diffraction interferometer system for testing an optical element that is positioned along an optical path including: a source of electromagnetic energy in the optical path; a first beam splitter that is secured to a device that includes means for maneuvering the first beam splitter in a first position wherein the first beam splitter is in the optical path dividing light from the source into a reference beam and a test beam and in a second position wherein the first beam splitter is outside the optical path: a hybrid mask which includes a first section that defines a test window and at least one reference pinhole and a second section that defines a second beam splitter wherein the hybrid mask is secured to a device that includes means for maneuvering either the first section or the second section into the optical path positioned in an image plane that is created by the optical element, with the proviso that the first section of the hybrid mask is positioned in the optical path when first beam splitter is positioned in the optical path; and a detector positioned after the hybrid mask along the optical path.

  7. The Effect of Conventional and Transparent Surgical Masks on Speech Understanding in Individuals with and without Hearing Loss.

    PubMed

    Atcherson, Samuel R; Mendel, Lisa Lucks; Baltimore, Wesley J; Patro, Chhayakanta; Lee, Sungmin; Pousson, Monique; Spann, M Joshua

    2017-01-01

    It is generally well known that speech perception is often improved with integrated audiovisual input whether in quiet or in noise. In many health-care environments, however, conventional surgical masks block visual access to the mouth and obscure other potential facial cues. In addition, these environments can be noisy. Although these masks may not alter the acoustic properties, the presence of noise in addition to the lack of visual input can have a deleterious effect on speech understanding. A transparent ("see-through") surgical mask may help to overcome this issue. To compare the effect of noise and various visual input conditions on speech understanding for listeners with normal hearing (NH) and hearing impairment using different surgical masks. Participants were assigned to one of three groups based on hearing sensitivity in this quasi-experimental, cross-sectional study. A total of 31 adults participated in this study: one talker, ten listeners with NH, ten listeners with moderate sensorineural hearing loss, and ten listeners with severe-to-profound hearing loss. Selected lists from the Connected Speech Test were digitally recorded with and without surgical masks and then presented to the listeners at 65 dB HL in five conditions against a background of four-talker babble (+10 dB SNR): without a mask (auditory only), without a mask (auditory and visual), with a transparent mask (auditory only), with a transparent mask (auditory and visual), and with a paper mask (auditory only). A significant difference was found in the spectral analyses of the speech stimuli with and without the masks; however, no more than ∼2 dB root mean square. Listeners with NH performed consistently well across all conditions. Both groups of listeners with hearing impairment benefitted from visual input from the transparent mask. The magnitude of improvement in speech perception in noise was greatest for the severe-to-profound group. Findings confirm improved speech perception performance in noise for listeners with hearing impairment when visual input is provided using a transparent surgical mask. Most importantly, the use of the transparent mask did not negatively affect speech perception performance in noise. American Academy of Audiology

  8. Advances in Thin Film Thermocouple Durability Under High Temperature and Pressure Testing Conditions

    NASA Technical Reports Server (NTRS)

    Martin, Lisa C.; Fralick, Gustave C.; Taylor, Keith F.

    1999-01-01

    Thin film thermocouples for measuring material surface temperature have been previously demonstrated on several material systems and in various hostile test environments. A well-developed thin film fabrication procedure utilizing shadow masking for patterning the sensors elements had produced thin films with sufficient durability for applications in high temperature and pressure environments that exist in air-breathing and hydrogen-fueled burner rig and engine test facilities. However, while shadow masking had been a reliable method for specimens with flat and gently curved surfaces, it had not been consistently reliable for use on test components with sharp contours. This work reports on the feasibility of utilizing photolithography processing for patterning thin film thermocouples. Because this patterning process required changes in the thin film deposition process from that developed for shadow masking, the effect of these changes on thin film adherence during burner rig testing was evaluated. In addition to the results of changing the patterning method, the effects on thin film adherence of other processes used in the thin film fabrication procedure is also presented.

  9. Mask versus Nasal Tube for Stabilization of Preterm Infants at Birth: Respiratory Function Measurements.

    PubMed

    van Vonderen, Jeroen J; Kamlin, C Omar; Dawson, Jennifer A; Walther, Frans J; Davis, Peter G; te Pas, Arjan B

    2015-07-01

    To compare the nasal tube with face mask as interfaces for stabilization of very preterm infants at birth by using physiological measurements of leak, obstruction, and expired tidal volumes during positive pressure ventilation (PPV). In the delivery room, 43 infants <30 weeks gestation were allocated to receive respiratory support by nasal tube or face mask. Respiratory function, heart rate, and oxygen saturation were measured. Occurrence of obstruction, amount of leak, and tidal volumes were compared using a Mann-Whitney U test or a Fisher exact test. The first 5 minutes after initiation of PPV were analyzed (1566 inflations in the nasal tube group and 1896 inflations in the face mask group). Spontaneous breathing coincided with PPV in 32% of nasal tube and 34% of face mask inflations. During inflations, higher leak was observed using nasal tube compared with face mask (98% [33%-100%] vs 14 [0%-39%]; P < .0001). Obstruction occurred more often (8.2% vs 1.1%; P < .0001). Expired tidal volumes were significantly lower during inflations when using nasal tube compared with face mask (0.0 [0.0-3.1] vs 9.9 [5.5-12.8] mL/kg; P < .0001) and when spontaneous breathing coincided with PPV (4.4 [2.1-8.4] vs 9.6 [5.4-15.2] mL/kg; P < .0001) but were similar during breathing on continuous positive airway pressure (4.7 [2.8-6.9] vs 4.8 [2.7-7.9] mL/kg; P > 0.05). Heart rate was not significantly different between groups, but oxygen saturation was significantly lower in the nasal tube group the first 2 minutes after start of respiratory support. The use of a nasal tube led to large leak, more obstruction, and inadequate tidal volumes compared with face mask. Trial registration Registered with the Dutch Trial Registry (NTR 2061) and the Australia and New Zealand Clinical Trials Register (ACTRN 12610000230055). Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Factors affecting speech understanding in gated interference: Cochlear implant users and normal-hearing listeners

    NASA Astrophysics Data System (ADS)

    Nelson, Peggy B.; Jin, Su-Hyun

    2004-05-01

    Previous work [Nelson, Jin, Carney, and Nelson (2003), J. Acoust. Soc. Am 113, 961-968] suggested that cochlear implant users do not benefit from masking release when listening in modulated noise. The previous findings indicated that implant users experience little to no release from masking when identifying sentences in speech-shaped noise, regardless of the modulation frequency applied to the noise. The lack of masking release occurred for all implant subjects who were using three different devices and speech processing strategies. In the present study, possible causes of this reduced masking release in implant listeners were investigated. Normal-hearing listeners, implant users, and normal-hearing listeners presented with a four-band simulation of a cochlear implant were tested for their understanding of sentences in gated noise (1-32 Hz gate frequencies) when the duty cycle of the noise was varied from 25% to 75%. No systematic effect of noise duty cycle on implant and simulation listeners' performance was noted, indicating that the masking caused by gated noise is not only energetic masking. Masking release significantly increased when the number of spectral channels was increased from 4 to 12 for simulation listeners, suggesting that spectral resolution is important for masking release. Listeners were also tested for their understanding of gated sentences (sentences in quiet interrupted by periods of silence ranging from 1 to 32 Hz as a measure of auditory fusion, or the ability to integrate speech across temporal gaps. Implant and simulation listeners had significant difficulty understanding gated sentences at every gate frequency. When the number of spectral channels was increased for simulation listeners, their ability to understand gated sentences improved significantly. Findings suggest that implant listeners' difficulty understanding speech in modulated conditions is related to at least two (possibly related) factors: degraded spectral information and limitations in auditory fusion across temporal gaps.

  11. Masked Inhibitory Priming in English: Evidence for Lexical Inhibition

    ERIC Educational Resources Information Center

    Davis, Colin J.; Lupker, Stephen J.

    2006-01-01

    Predictions derived from the interactive activation (IA) model were tested in 3 experiments using the masked priming technique in the lexical decision task. Experiment 1 showed a strong effect of prime lexicality: Classifications of target words were facilitated by orthographically related nonword primes (relative to unrelated nonword primes) but…

  12. Attentional Sensitization of Unconscious Cognition: Task Sets Modulate Subsequent Masked Semantic Priming

    ERIC Educational Resources Information Center

    Kiefer, Markus; Martens, Ulla

    2010-01-01

    According to classical theories, automatic processes are autonomous and independent of higher level cognitive influence. In contrast, the authors propose that automatic processing depends on attentional sensitization of task-congruent processing pathways. In 3 experiments, the authors tested this hypothesis with a modified masked semantic priming…

  13. 78 FR 23458 - Airworthiness Directives; Dassault Aviation Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-19

    ... aircraft flight manual (AFM); performing operational tests of the oxygen mask oxygen assembly; and... prompted by failure of the flight crew oxygen supply due to a potentially defective flight crew mask oxygen assembly. We are issuing this AD to prevent failure to supply oxygen upon demand to the flight crew in...

  14. Performance of a continuous flow passenger oxygen mask at an altitude of 40,000 feet.

    DOT National Transportation Integrated Search

    1996-02-01

    A redesigned continuous flow passenger oxygen mask was tested for its ability to deliver an adequate supply of oxygen at an altitude of 40,000 feet above sea level. Four male subjects participated in the study. Blood oxygen saturation (SaO2) baseline...

  15. Forward-masking based gain control in odontocete biosonar: an evoked-potential study.

    PubMed

    Supin, Alexander Ya; Nachtigall, Paul E; Breese, Marlee

    2009-04-01

    Auditory evoked potentials (AEPs) were recorded during echolocation in a false killer whale Pseudorca crassidens. An electronically synthesized and played-back ("phantom") echo was used. Each electronic echo was triggered by an emitted biosonar pulse. The echo had a spectrum similar to that of the emitted biosonar clicks, and its intensity was proportional to that of the emitted click. The attenuation of the echo relative to the emitted click and its delay was controlled by the experimenter. Four combinations of echo attenuation and delay were tested (-31 dB, 2 ms), (-40 dB, 4 ms), (-49 dB, 8 ms), and (-58 dB, 16 ms); thus, attenuation and delay were associated with a rate of 9 dB of increased attenuation per delay doubling. AEPs related to emitted clicks displayed a regular amplitude dependence on the click level. Echo-related AEPs did not feature amplitude dependence on echo attenuation or emitted click levels, except in a few combinations of the lowest values of these two variables. The results are explained by a hypothesis that partial forward masking of the echoes by the preceding emitted sonar pulses serves as a kind of automatic gain control in the auditory system of echolocating odontocetes.

  16. A novel methodology for building robust design rules by using design based metrology (DBM)

    NASA Astrophysics Data System (ADS)

    Lee, Myeongdong; Choi, Seiryung; Choi, Jinwoo; Kim, Jeahyun; Sung, Hyunju; Yeo, Hyunyoung; Shim, Myoungseob; Jin, Gyoyoung; Chung, Eunseung; Roh, Yonghan

    2013-03-01

    This paper addresses a methodology for building robust design rules by using design based metrology (DBM). Conventional method for building design rules has been using a simulation tool and a simple pattern spider mask. At the early stage of the device, the estimation of simulation tool is poor. And the evaluation of the simple pattern spider mask is rather subjective because it depends on the experiential judgment of an engineer. In this work, we designed a huge number of pattern situations including various 1D and 2D design structures. In order to overcome the difficulties of inspecting many types of patterns, we introduced Design Based Metrology (DBM) of Nano Geometry Research, Inc. And those mass patterns could be inspected at a fast speed with DBM. We also carried out quantitative analysis on PWQ silicon data to estimate process variability. Our methodology demonstrates high speed and accuracy for building design rules. All of test patterns were inspected within a few hours. Mass silicon data were handled with not personal decision but statistical processing. From the results, robust design rules are successfully verified and extracted. Finally we found out that our methodology is appropriate for building robust design rules.

  17. In vitro and in vivo investigation of taste-masking effectiveness of Eudragit E PO as drug particle coating agent in orally disintegrating tablets.

    PubMed

    Drašković, Milica; Medarević, Djordje; Aleksić, Ivana; Parojčić, Jelena

    2017-05-01

    Considering that bitter taste of drugs incorporated in orally disintegrating tablets (ODTs) can be the main reason for avoiding drug therapy, it is of the utmost importance to achieve successful taste-masking. The evaluation of taste-masking effectiveness is still a major challenge. The objective of this study was to mask bitter taste of the selected model drugs by drug particle coating with Eudragit ® E PO, as well as to evaluate taste-masking effectiveness of prepared ODTs using compendial dissolution testing, dissolution in the small-volume shake-flask assembly and trained human taste panel. Model drugs were coated in fluidized bed. Disintequik™ ODT was used as a novel co-processed excipient for ODT preparation. Selected formulations were investigated in vitro and in vivo using techniques for taste-masking assessment. Significantly slower drug dissolution was observed from tablets with coated drug particles during the first 3 min of investigation. Results of in vivo taste-masking assessment demonstrated significant improvement in drug bitterness suppression in formulations with coated drug. Strong correlation between the results of drug dissolution in the small-volume shake-flask assembly and in vivo evaluation data was established (R ≥ 0.970). Drug particle coating with Eudragit ® E PO can be a suitable approach for bitter taste-masking. Strong correlation between in vivo and in vitro results implicate that small-volume dissolution method may be used as surrogate for human panel taste-masking assessment, in the case of physical taste-masking approach application.

  18. Respiratory source control using a surgical mask: An in vitro study.

    PubMed

    Patel, Rajeev B; Skaria, Shaji D; Mansour, Mohamed M; Smaldone, Gerald C

    2016-07-01

    Cough etiquette and respiratory hygiene are forms of source control encouraged to prevent the spread of respiratory infection. The use of surgical masks as a means of source control has not been quantified in terms of reducing exposure to others. We designed an in vitro model using various facepieces to assess their contribution to exposure reduction when worn at the infectious source (Source) relative to facepieces worn for primary (Receiver) protection, and the factors that contribute to each. In a chamber with various airflows, radiolabeled aerosols were exhaled via a ventilated soft-face manikin head using tidal breathing and cough (Source). Another manikin, containing a filter, quantified recipient exposure (Receiver). The natural fit surgical mask, fitted (SecureFit) surgical mask and an N95-class filtering facepiece respirator (commonly known as an "N95 respirator") with and without a Vaseline-seal were tested. With cough, source control (mask or respirator on Source) was statistically superior to mask or unsealed respirator protection on the Receiver (Receiver protection) in all environments. To equal source control during coughing, the N95 respirator must be Vaseline-sealed. During tidal breathing, source control was comparable or superior to mask or respirator protection on the Receiver. Source control via surgical masks may be an important adjunct defense against the spread of respiratory infections. The fit of the mask or respirator, in combination with the airflow patterns in a given setting, are significant contributors to source control efficacy. Future clinical trials should include a surgical mask source control arm to assess the contribution of source control in overall protection against airborne infection.

  19. Two-dimensional analytical modeling of a linear variable filter for spectral order sorting.

    PubMed

    Ko, Cheng-Hao; Wu, Yueh-Hsun; Tsai, Jih-Run; Wang, Bang-Ji; Chakraborty, Symphony

    2016-06-10

    A two-dimensional thin film thickness model based on the geometry of a commercial coater which can calculate more effectively the profiles of linear variable filters (LVFs) has been developed. This is done by isolating the substrate plane as an independent coordinate (local coordinate), while the rotation and translation matrices are used to establish the coordinate transformation and combine the characteristic vector with the step function to build a borderline which can conclude whether the local mask will block the deposition or not. The height of the local mask has been increased up to 40 mm in the proposed model, and two-dimensional simulations are developed to obtain a thin film profile deposition on the substrate inside the evaporation chamber to achieve the specific request of producing a LVF zone width in a more economical way than previously reported [Opt. Express23, 5102 (2015)OPEXFF1094-408710.1364/OE.23.005102].

  20. Effects of subliminally presented auditory suggestions of itching on scratching behavior.

    PubMed

    Mitchell, C W

    1995-02-01

    This study investigated effects of masked verbal suggestions of itching, utilizing a design closely analogous to commercially available subliminal audiotapes. Students participated in 1 of 3 groups (n = 21): an experimental group listened to an audiotape with music masking suggestions of itching, Control Group 1 listened to an audiotape with music only, and Control Group 2 listened to suggestions of itching presented supraliminally. Dependent variables included both behavioral and self-report measures of itching. There was no evidence of influence from subliminal suggestion; however, results assessing the influence of supraliminally presented suggestions were mixed for self-report and behavioral measures.

  1. The Relationship between MOC Reflex and Masked Threshold

    PubMed Central

    Garinis, Angela; Werner, Lynne; Abdala, Carolina

    2011-01-01

    Otoacoustic emission (OAE) amplitude can be reduced by acoustic stimulation. This effect is produced by the medial olivocochlear (MOC) reflex. Past studies have shown that the MOC reflex is related to listening in noise and attention. In the present study, the relationship between strength of the contralateral MOC reflex and masked threshold was investigated in 19 adults. Detection thresholds were determined for a 1000-Hz, 300-ms tone presented simultaneously with one repetition of a 300-ms masker in an ongoing train of 300-ms masker bursts at 600-ms intervals. Three masking conditions were tested: 1) broadband noise 2) a fixed-frequency 4-tone complex masker and 3) a random-frequency 4-tone complex masker. Broadband noise was expected to produce energetic masking and the tonal maskers were expected to produce informational masking in some listeners. DPOAEs were recorded at fine frequency interval from 500 to 4000 Hz, with and without contralateral acoustic stimulation. MOC reflex strength was estimated as a reduction in baseline level and a shift in frequency of DPOAE fine-structure maxima near 1000-Hz. MOC reflex and psychophysical testing were completed in separate sessions. Individuals with poorer thresholds in broadband noise and in random-frequency maskers were found to have stronger MOC reflexes. PMID:21878379

  2. XBAER-derived aerosol optical thickness from OLCI/Sentinel-3 observation

    NASA Astrophysics Data System (ADS)

    Mei, Linlu; Rozanov, Vladimir; Vountas, Marco; Burrows, John P.; Richter, Andreas

    2018-02-01

    A cloud identification algorithm used for cloud masking, which is based on the spatial variability of reflectances at the top of the atmosphere in visible wavelengths, has been developed for the retrieval of aerosol properties by MODIS. It is shown that the spatial pattern of cloud reflectance, as observed from space, is very different from that of aerosols. Clouds show a high spatial variability in the scale of a hundred metres to a few kilometres, whereas aerosols in general are homogeneous. The concept of spatial variability of reflectances at the top of the atmosphere is mainly applicable over the ocean, where the surface background is sufficiently homogeneous for the separation between aerosols and clouds. Aerosol retrievals require a sufficiently accurate cloud identification to be able to mask these ground scenes. However, a conservative mask will exclude strong aerosol episodes and a less conservative mask could introduce cloud contamination that biases the retrieved aerosol optical properties (e.g. aerosol optical depth and effective radii). A detailed study on the effect of cloud contamination on aerosol retrievals has been performed and parameters are established determining the threshold value for the MODIS aerosol cloud mask (3×3-STD) over the ocean. The 3×3-STD algorithm discussed in this paper is the operational cloud mask used for MODIS aerosol retrievals over the ocean.A prolonged pollution haze event occurred in the northeast part of China during the period 16-21 December 2016. To assess the impact of such events, the amounts and distribution of aerosol particles, formed in such events, need to be quantified. The newly launched Ocean Land Colour Instrument (OLCI) onboard Sentinel-3 is the successor of the MEdium Resolution Imaging Spectrometer (MERIS). It provides measurements of the radiance and reflectance at the top of the atmosphere, which can be used to retrieve the aerosol optical thickness (AOT) from synoptic to global scales. In this study, the recently developed AOT retrieval algorithm eXtensible Bremen AErosol Retrieval (XBAER) has been applied to data from the OLCI instrument for the first time to illustrate the feasibility of applying XBAER to the data from this new instrument. The first global retrieval results show similar patterns of aerosol optical thickness, AOT, to those from MODIS and MISR aerosol products. The AOT retrieved from OLCI is validated by comparison with AERONET observations and a correlation coefficient of 0.819 and bias (root mean square) of 0.115 is obtained. The haze episode is well captured by the OLCI-derived AOT product. XBAER is shown to retrieve AOT well from the observations of MERIS and OLCI.

  3. Projection Exposure with Variable Axis Immersion Lenses: A High-Throughput Electron Beam Approach to “Suboptical” Lithography

    NASA Astrophysics Data System (ADS)

    Pfeiffer, Hans

    1995-12-01

    IBM's high-throughput e-beam stepper approach PRojection Exposure with Variable Axis Immersion Lenses (PREVAIL) is reviewed. The PREVAIL concept combines technology building blocks of our probe-forming EL-3 and EL-4 systems with the exposure efficiency of pattern projection. The technology represents an extension of the shaped-beam approach toward massively parallel pixel projection. As demonstrated, the use of variable-axis lenses can provide large field coverage through reduction of off-axis aberrations which limit the performance of conventional projection systems. Subfield pattern sections containing 107 or more pixels can be electronically selected (mask plane), projected and positioned (wafer plane) at high speed. To generate the entire chip pattern subfields must be stitched together sequentially in a combination of electronic and mechanical positioning of mask and wafer. The PREVAIL technology promises throughput levels competitive with those of optical steppers at superior resolution. The PREVAIL project is being pursued to demonstrate the viability of the technology and to develop an e-beam alternative to “suboptical” lithography.

  4. More Realistic Face Model Surface Improves Relevance of Pediatric In-Vitro Aerosol Studies.

    PubMed

    Amirav, Israel; Halamish, Asaf; Gorenberg, Miguel; Omar, Hamza; Newhouse, Michael T

    2015-01-01

    Various hard face models are commonly used to evaluate the efficiency of aerosol face masks. Softer more realistic "face" surface materials, like skin, deform upon mask application and should provide more relevant in-vitro tests. Studies that simultaneously take into consideration many of the factors characteristic of the in vivo face are lacking. These include airways, various application forces, comparison of various devices, comparison with a hard-surface model and use of a more representative model face based on large numbers of actual faces. To compare mask to "face" seal and aerosol delivery of two pediatric masks using a soft vs. a hard, appropriately representative, pediatric face model under various applied forces. Two identical face models and upper airways replicas were constructed, the only difference being the suppleness and compressibility of the surface layer of the "face." Integrity of the seal and aerosol delivery of two different masks [AeroChamber (AC) and SootherMask (SM)] were compared using a breath simulator, filter collection and realistic applied forces. The soft "face" significantly increased the delivery efficiency and the sealing characteristics of both masks. Aerosol delivery with the soft "face" was significantly greater for the SM compared to the AC (p< 0.01). No statistically significant difference between the two masks was observed with the hard "face." The material and pliability of the model "face" surface has a significant influence on both the seal and delivery efficiency of face masks. This finding should be taken into account during in-vitro aerosol studies.

  5. Solid lipid microparticles containing loratadine prepared using a Micromixer.

    PubMed

    Milak, Spomenka; Medlicott, Natalie; Tucker, Ian G

    2006-12-01

    Solid lipid microparticles were investigated as a taste-masking approach for a lipophilic weak base in a suspension. The idea was that the drug concentration in the aqueous phase of a suspension might be reduced by its partitioning into the solid lipid particles. Loratadine, as a model drug, was used to prepare Precirol ATO 5 microparticles by a Micromixer. The effects of three process variables: drug loading, PVA concentration and water/lipid ratio on the microparticle size, encapsulation efficiency, surface appearance, in-vitro release and drug partitioning in a suspension were studied. Loratadine release was slow in simulated saliva and very fast at the pH of stomach. In suspension of loratadine lipid microparticles, drug was released into the aqueous phase to the same concentration as in a drug suspension. Therefore, the usefulness of these microparticles for taste-masking in liquids is limited. However, they might be useful for taste-masking in solid dosage forms.

  6. Don't kill canaries! Introducing a new test device to assess the electrostatic risk potential to photomasks

    NASA Astrophysics Data System (ADS)

    Sebald, Thomas

    2008-10-01

    Electrostatic protection is an issue for all masks, whether during mask production, shipping, storage, handling or inspection and exposure. Up to now, only manual electrostatic field measurements, or expensive and elaborate analyses with Canary reticles have given hints about the risks of pattern damage by ESD events. A new test device is being introduced, which consists of electrostatic field sensors, integrated INSIDE a closed fused quartz housing which has the outside dimensions of a 6 inch mask. This device can be handled and used like a normal 6 inch reticle. It can be handled and processed while recording the electrostatic charges on the chrome patterns created by friction or field induction just as a reticle would "see" during normal processing.

  7. E-beam generated holographic masks for optical vector-matrix multiplication

    NASA Technical Reports Server (NTRS)

    Arnold, S. M.; Case, S. K.

    1981-01-01

    An optical vector matrix multiplication scheme that encodes the matrix elements as a holographic mask consisting of linear diffraction gratings is proposed. The binary, chrome on glass masks are fabricated by e-beam lithography. This approach results in a fairly simple optical system that promises both large numerical range and high accuracy. A partitioned computer generated hologram mask was fabricated and tested. This hologram was diagonally separated outputs, compact facets and symmetry about the axis. The resultant diffraction pattern at the output plane is shown. Since the grating fringes are written at 45 deg relative to the facet boundaries, the many on-axis sidelobes from each output are seen to be diagonally separated from the adjacent output signals.

  8. Accelerator test of the coded aperture mask technique for gamma-ray astronomy

    NASA Technical Reports Server (NTRS)

    Jenkins, T. L.; Frye, G. M., Jr.; Owens, A.; Carter, J. N.; Ramsden, D.

    1982-01-01

    A prototype gamma-ray telescope employing the coded aperture mask technique has been constructed and its response to a point source of 20 MeV gamma-rays has been measured. The point spread function is approximately a Gaussian with a standard deviation of 12 arc minutes. This resolution is consistent with the cell size of the mask used and the spatial resolution of the detector. In the context of the present experiment, the error radius of the source position (90 percent confidence level) is 6.1 arc minutes.

  9. Contrast ratio and masking ability of three ceramic veneering materials.

    PubMed

    Shono, N N; Al Nahedh, H N A

    2012-01-01

    Porcelain veneer materials are translucent and are therefore affected by their thickness as well as the color of the underlying substructure, which limits their masking ability and compromises the esthetic result in heavily stained teeth. The purpose of this study was to compare the contrast ratio (CR) and masking ability of three different veneering ceramics with two thicknesses by measuring the color differences over white and black backgrounds. Correlations between CR and masking ability of these veneering ceramics were evaluated. A total of 30 disc-shaped specimens (12 mm diameter × 1.0 mm or 1.5 mm) were fabricated in shade A2 from three types of all-ceramic systems: IPS e.max Press (IPSe; Ivoclar Vivadent, Schaan, Liechtensein), Vita VM7 (VM7; VITA Zahnfabrik, Bad Säckingen, Germany), and Nobel Rondo Press Alumina: Solo (NRPA; Nobel Biocare, Zürich-Flughafen, Switzerland). The CR, defined as the ratio of illuminance (Y) of the test material when placed on the black background (Yb) to the illuminance of the same material when placed over a white background (Yw), was determined (CR=Yb/Yw). The color (CIE L*a*b*) and Y of each specimen were measured over standard white and black tiles using a spectrophotometer (ColorEye 7000 A, Model C6, GretagMacbeth, New Windsor, NY, USA). Masking abilities of the specimens were determined by measuring the color difference (ΔE) over white and black backgrounds. Both CR and ΔE data were analyzed using two-way analysis of variance (ANOVA). One-way ANOVA was used to compare the mean values of CR across the three materials followed by the Duncan multiple comparison test. The correlations between CR and ΔE were determined by comparing R(2) values obtained from a linear regression analysis. A Student t-test for independent samples was used to compare the mean contrast ratio and ΔE values for the two thicknesses. CR values of NRPA were significantly less than those of IPSe and VM7, and the CR of IPSe was higher than that of VM7. Furthermore, CR increased as the thickness of the discs increased to 1.5 mm for all three materials. Mean ΔE values were significantly higher with 1.0-mm-thick discs than with 1.5-mm discs. Among the three materials it was observed that NRPA had the highest ΔE when compared with IPSe or VM7, whereas the ΔE of the latter two were not significantly different from one another. There was a strong linear correlation between CR and masking ability. CR and masking ability are affected by the type as well as the thickness of the ceramic used. IPSe and VM7 are similar in their masking abilities, whereas NRPA had the lowest masking ability. NRPA was the most translucent, followed by VM7; IPSe was the most opaque. None of the materials tested was able to completely mask the black background. It is therefore recommended that the type of ceramic should be chosen according to each clinical situation.

  10. Higher Blood Pressure Variability in White Coat Hypertension; from the Korean Ambulatory Blood Pressure Monitoring Registry

    PubMed Central

    Kang, In Sook; Shin, Jinho; Ihm, Sang-Hyun; Kim, Ju Han; Park, Sungha; Kim, Kwang-Il; Kim, Woo-Shik; Kim, Soon Gil; Shin, Gil Ja

    2016-01-01

    Background and Objectives Blood pressure variability (BPV) was recently shown to be a risk factor of stroke. White coat hypertension (WCH) used to be regarded as innocuous, but one long-term follow-up study reported that WCH increased stroke rate compared to normotension (NT). In this study, we aimed to evaluate the relationship between WCH and BPV. Subjects and Methods We analyzed 1398 subjects from the Korean Ambulatory Blood Pressure Registry, who were divided into NT (n=364), masked hypertension (n=122), white coat hypertension (n=254), and sustained hypertension (n=658) groups. Results Baseline characteristics were similar among groups. The average real variability (ARV), a highly sensitive BPV parameter, was highest in the WCH group, followed by the sustained hypertension, masked hypertension, and NT groups. The results persisted after being adjusted for covariates. The WCH vs. sustained hypertension results (adjusted mean±standard error) were as follows: 24-h systolic ARV, 22.9±0.8 vs. 19.4±0.6; 24-h diastolic ARV, 16.8±0.6 vs. 14.3±0.5; daytime systolic ARV, 21.8±0.8 vs. 16.8±0.6; and daytime diastolic ARV, 16.2±0.6 vs. 13.4±0.5 (p<0.001 for all comparisons). Conclusion From the registry data, we found that subjects with WCH or masked hypertension had higher BPV than NT. However, long-term follow-up data assessing the clinical influences of WCH on stroke are needed. PMID:27275173

  11. Characterization of Carbon Dioxide Washout Measurement Techniques in the Mark-III Space Suit

    NASA Technical Reports Server (NTRS)

    Meginnis, I; Norcross, J.; Bekdash, O.

    2016-01-01

    It is essential to provide adequate carbon dioxide (CO2) washout in a space suit to reduce the risks associated with manned operations in space suits. Symptoms of elevated CO2 levels range from reduced cognitive performance and headache to unconsciousness and death at high levels of CO2. Because of this, NASA imposes limits on inspired CO2 levels for space suits when they are used in space and for ground testing. Testing and/or analysis must be performed to verify that a space suit meets CO2 washout requirements. Testing for developmental space suits has traditionally used an oronasal mask that collects CO2 samples at the left and rights sides of the mouth. Testing with this mask resulted in artificially elevated CO2 concentration measurements, which is most likely due to the dead space volume at the front of the mask. The mask also extends outward and into the supply gas stream, which may disrupt the washout effect of the suit supply gas. To mitigate these problems, a nasal cannula was investigated as a method for measuring inspired CO2 based on the assumptions that it is low profile and would not interfere with the designed suit gas flow path, and it has reduced dead space. This test series compared the performance of a nasal cannula to the oronasal mask in the Mark III space suit. Inspired CO2 levels were measured with subjects at rest and at metabolic workloads of 1000, 2000, and 3000 BTU/hr. Workloads were achieved by use of an arm ergometer or treadmill. Test points were conducted at air flow rates of 2, 4, and 6 actual cubic feet per minute, with a suit pressure of 4.3 psid. Results from this test series will evaluate the accuracy and repeatability across subjects of the nasal cannula collection method, which will provide rationale for using a nasal cannula as the new method for measuring inspired CO2 in a space suit. Proper characterization of sampling methods and of suit CO2 washout capability will better inform requirements definition and verification techniques for future CO2 washout limits in space suits

  12. Masked nonword repetition effects in yes/no and go/no-go lexical decision: a test of the evidence accumulation and deadline accounts.

    PubMed

    Perea, Manuel; Gómez, Pablo; Fraga, Isabel

    2010-06-01

    The pattern of masked repetition priming effects for word and nonword targets differs across tasks: Masked-priming effects in lexical decision occur for positive responses (i.e., words), but not for negative responses (nonwords), whereas masked-priming effects in the cross-case same-different task occur for positive responses (same), but not for negative responses (different)--regardless of lexical status. Here, we examined whether masked nonword priming effects are greater when the task involves an active go response to nonwords than when it involves the standard yes/no procedure in lexical decision. The obtained masked repetition priming effect for nonwords was of similar size in yes/no and go/no-go tasks. This finding is compatible with accounts of nonword priming that posit that nonword responses are produced by actively accumulating evidence for the nonword alternative in yes/no and go/no-go procedures, whereas it is inconsistent with the assumption of a deadline for no responses in the yes/no task.

  13. Achromatic Focal Plane Mask for Exoplanet Imaging Coronagraphy

    NASA Technical Reports Server (NTRS)

    Newman, Kevin Edward; Belikov, Ruslan; Guyon, Olivier; Balasubramanian, Kunjithapatham; Wilson, Dan

    2013-01-01

    Recent advances in coronagraph technologies for exoplanet imaging have achieved contrasts close to 1e10 at 4 lambda/D and 1e-9 at 2 lambda/D in monochromatic light. A remaining technological challenge is to achieve high contrast in broadband light; a challenge that is largely limited by chromaticity of the focal plane mask. The size of a star image scales linearly with wavelength. Focal plane masks are typically the same size at all wavelengths, and must be sized for the longest wavelength in the observational band to avoid starlight leakage. However, this oversized mask blocks useful discovery space from the shorter wavelengths. We present here the design, development, and testing of an achromatic focal plane mask based on the concept of optical filtering by a diffractive optical element (DOE). The mask consists of an array of DOE cells, the combination of which functions as a wavelength filter with any desired amplitude and phase transmission. The effective size of the mask scales nearly linearly with wavelength, and allows significant improvement in the inner working angle of the coronagraph at shorter wavelengths. The design is applicable to almost any coronagraph configuration, and enables operation in a wider band of wavelengths than would otherwise be possible. We include initial results from a laboratory demonstration of the mask with the Phase Induced Amplitude Apodization coronagraph.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kalavagunta, C; Lin, M; Snider, J

    Purpose: To quantify the factors leading to thermoplastic mask bolus-associated-increased skin dose in head and neck IMRT/VMAT using EBT2 film. Methods: EBT2 film placed beneath a dual layer 3-point ORFIT head, neck and shoulder mask was used to test the effect of mask thickness, beam modulation, air gap, and beam obliquity on bolus effect. Mask thickness was varied based on the distribution of 1.6mm Orfilight layer on top of 2 mm Efficast layer. Beam modulation was varied by irradiating the film with an open field (no beam modulation) and a step and shoot field (beam modulation). Air gap between maskmore » and film was varied from 0 to 5mm. Beam obliquity was varied by irradiating the film at gantry angles of 0°, 35°, and 70°.Finally, film strips placed on a Rando phantom under an Orfit mask, in regions of expected high dose, were irradiated using 5 IMRT and 5 VMAT plans with various modulation levels (modulation factor 2 to 5) and the results were compared with those obtained placing OSLDs at the same locations. Results: An 18–34% increase in mask bolus effect was observed for three factors where the effect of beam obliquity ≥ beam modulation > mask thickness. No increase in mask bolus effect was observed for change in air gap. A 6–13% increase in dose due to mask bolus effect was observed on film strips. Conclusion: This work underlines the role of beam obliquity and beam modulation combined with thermoplastic mask thickness in increasing mask bolus-associated skin dose in head and neck IMRT/VMAT. One possible method of dose reduction, based on knowledge gained from this work, is inclusion of skin as an avoidance structure in treatment planning. Another approach is to design a mask with the least amount of thermoplastic material necessary for immobilization.« less

  15. Palatability of a Novel Oral Formulation of Prednisone in Healthy Young Adults

    PubMed Central

    Bai, Shasha; Dormer, Nathan; Shoults, Catherine; Meyer, Amanda; Pierce, Carol D'Ann; Neville, Kathleen A.; Kearns, Gregory L.

    2017-01-01

    Objectives Prednisone is a widely used anti-inflammatory for a variety of conditions. While oral liquid formulations of prednisone enable weight-based dosing, children frequently find them to be objectionable due to bitter taste. This limitation of prednisone can adversely impact patient acceptance and may result in non-compliance. Efforts to mask flavors often result in poorly controlled, heterogeneous particle distributions and can provide ineffective taste masking. The present work utilized a novel drug delivery technology developed by Orbis Biosciences, Inc., to create an oral taste-masked formulation of prednisone. Methods The study examined the palatability of Orbis’ microsphere prednisone formulation in healthy young adults (n=24). Four test articles were used in the study including a reference formulation (Roxane Laboratories), a control, and the test formulation (Orbis) prepared in two different ways. Study participants were randomized in a crossover design. Key Findings Results indicated that the test prednisone formulation was indistinguishable from the control, and both were preferable to the reference formulation in every category of palatability assessed using a validated 9-point Hedonic Scale. The data also suggested that preparing the microsphere suspension immediately prior to administration results in the most ideal palatability properties. Conclusions In conclusion, the novel microsphere formulation technology was effective in taste-masking prednisone. PMID:28271493

  16. Comparison of Comfort and Effectiveness of Total Face Mask and Oronasal Mask in Noninvasive Positive Pressure Ventilation in Patients with Acute Respiratory Failure: A Clinical Trial.

    PubMed

    Sadeghi, Somayeh; Fakharian, Atefeh; Nasri, Peiman; Kiani, Arda

    2017-01-01

    Background . There is a growing controversy about the use of oronasal masks (ONM) or total facemask (TFM) in noninvasive positive pressure ventilation (NPPV), so we designed a trial to compare the uses of these two masks in terms of effectiveness and comfort. Methods . Between February and November 2014, a total of 48 patients with respiratory failure were studied. Patients were randomized to receive NPPV via ONM or TFM. Data were recorded at 60 minutes and six and 24 hours after intervention. Patient comfort was assessed using a questionnaire. Data were analyzed using t -test and chi-square test. Repeated measures ANOVA and Mann-Whitney U test were used to compare clinical and laboratory data. Results . There were no differences in venous blood gas (VBG) values between the two groups ( P > 0.05). However, at six hours, TFM was much more effective in reducing the partial pressure of carbon dioxide (PCO2) ( P = 0.04). Patient comfort and acceptance were statistically similar in both groups ( P > 0.05). Total time of NPPV was also similar in the two groups ( P > 0.05). Conclusions . TFM was superior to ONM in acute phase of respiratory failure but not once the patients were out of acute phase.

  17. Alexithymia in anorexia nervosa: the mediating role of depression.

    PubMed

    Torres, Sandra; Guerra, Marina Prista; Lencastre, Leonor; Miller, Kylee; Vieira, Filipa Mucha; Roma-Torres, António; Brandão, Isabel; Costa, Patrício

    2015-01-30

    The role of depression in the expression of alexithymia in anorexia nervosa (AN) has been controversially explained and several variables that may mask or increase the presence of emotional difficulties have scant examination in previous studies. This study aims to analyze the associations between alexithymia and state variables, such as age, BMI, illness duration, treatment duration, and medication status in AN participants, and to test the mediating role of depression in emotional difficulties. The Toronto Alexithymia Scale (TAS-20) and the Zung Self-Rating Depression Scale were administrated to 160 females: 80 participants with AN and 80 healthy controls. High levels of alexithymia were not a function of state variables. The mediating role of depression differed by the alexithymia dimension, with total mediation found for the TAS-DDF and partial mediation found for the TAS-DIF. Alexithymia is a relevant feature throughout the spectrum of AN and does not seem to be related to developmental maturation and some clinical features. Depression is probably the variable that best accounts for the variance in alexithymia, but is not a complete explanation for the known cognitive-affective disturbances in AN. Specific emotional competencies require scrutiny during psychiatric treatment. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  18. Effect of Three Different Core Materials on Masking Ability of a Zirconia Ceramic.

    PubMed

    Tabatabaian, Farhad; Masoomi, Faeze; Namdari, Mahshid; Mahshid, Minoo

    2016-09-01

    Masking ability of a restorative material plays a role in hiding colored substructures; however, the masking ability of zirconia ceramic (ZRC) has not yet been clearly understood in zirconia-based restorations. This study evaluated the effect of three different core materials on masking ability of a ZRC. Ten zirconia disc samples, 0.5mm in thickness and 10mm in diameter, were fabricated. A white (W) substrate (control) and three substrates of nickel-chromium alloy (NCA), non-precious gold alloy (NPGA), and ZRC were prepared. The zirconia discs were placed on the four types of substrates for spectrophotometry. The L*, a*, and b* values of the specimens were measured by a spectrophotometer and color change (ΔE) values were calculated to determine color differences between the test and control groups and were then compared with the perceptual threshold. Randomized block ANOVA and Bonferroni test analyzed the data. A significance level of 0.05 was considered. The mean and standard deviation values of ΔE for NCA, NPGA, and ZRC groups were 10.26±2.43, 9.45±1.74, and 6.70±1.91 units, respectively. Significant differences were found in the ΔE values between ZRC and the other two experimental groups (NCA and NPGA; P<0.0001 and P=0.001, respectively). The ΔE values for the groups were more than the predetermined perceptual threshold. Within the limitations of this study, it was concluded that the tested ZRC could not well mask the examined core materials.

  19. Masked Priming with Orthographic Neighbors: A Test of the Lexical Competition Assumption

    ERIC Educational Resources Information Center

    Nakayama, Mariko; Sears, Christopher R.; Lupker, Stephen J.

    2008-01-01

    In models of visual word identification that incorporate inhibitory competition among activated lexical units, a word's higher frequency neighbors will be the word's strongest competitors. Preactivation of these neighbors by a prime is predicted to delay the word's identification. Using the masked priming paradigm (K. I. Forster & C. Davis, 1984,…

  20. The Role of Low-Spatial Frequencies in Lexical Decision and Masked Priming

    ERIC Educational Resources Information Center

    Boden, C.; Giaschi, D.

    2009-01-01

    Spatial frequency filtering was used to test the hypotheses that low-spatial frequency information in printed text can: (1) lead to a rapid lexical decision or (2) facilitate word recognition. Adult proficient readers made lexical decisions in unprimed and masked repetition priming experiments with unfiltered, low-pass, high-pass and notch…

  1. The characteristics of bacterial nanocellulose gel releasing silk sericin for facial treatment.

    PubMed

    Aramwit, Pornanong; Bang, Nipaporn

    2014-12-09

    Recently, naturally derived facial masks with beneficial biological properties have received increasing interest. In this study, silk sericin-releasing bacterial nanocellulose gel was developed to be applied as a bioactive mask for facial treatment. The silk sericin-releasing bacterial nanocellulose gel produced at a pH of 4.5 had an ultrafine and extremely pure fiber network structure. The mechanical properties and moisture absorption ability of the gel were improved, compared to those of the commercially available paper mask. Silk sericin could be control-released from the gel. A peel test with porcine skin showed that the gel was less adhesive than the commercially available paper mask, which would be removed from the face more easily without pain. The in vitro cytotoxicity test showed that the gel was not toxic to L929 mouse fibroblast and HaCaT human keratinocyte cells. Furthermore, when implanted subcutaneously and evaluated according to ISO10993-6 standard, the gel was not irritant to tissue. The silk sericin-releasing bacterial nanocellulose gel had appropriate physical and biological properties and safety for the facial treatment application.

  2. Evaporated As2S3 Luneburg lenses for LiNbO3:Ti optical waveguides

    NASA Technical Reports Server (NTRS)

    Busch, J. R.; Wood, V. E.; Kenan, R. P.; Verber, C. M.

    1981-01-01

    Luneburg lenses of good quality were formed on high index optical waveguides by evaporation of arsenic trisulfide glass through simple masks. Using only two thin circular aperture masks, lenses with focal spots of a few times the diffraction limited width at f/4 were obtained. These lenses were designed for and tested at both visible (633 nm) and infrared wavelengths. Procedures for the design, fabrication, and testing of lenses of this type are described.

  3. Determinants of Unintentional Leaks During CPAP Treatment in OSA.

    PubMed

    Lebret, Marius; Arnol, Nathalie; Martinot, Jean-Benoît; Lambert, Loïc; Tamisier, Renaud; Pepin, Jean-Louis; Borel, Jean-Christian

    2018-04-01

    Unintentional leakage from the mouth or around the mask may lead to cessation of CPAP treatment; however, the causes of unintentional leaks are poorly understood. The objectives of this study were (1) to identify determining factors of unintentional leakage and (2) to determine the effect of the type of mask (nasal/oronasal) used on unintentional leakage. Seventy-four polysomnograms from patients with OSA syndrome treated with auto-CPAP were analyzed (23 women; 56 ± 13 years; BMI, 32.9 kg/m 2 (range, 29.0-38.0 kg/m 2 ). Polysomnographic recordings were obtained under auto-CPAP, and mandibular behavior was measured with a magnetic sensor. After sleep and respiratory scoring, polysomnographic signals were computed as mean values over nonoverlapping 10-s intervals. The presence/absence of unintentional leakage was dichotomized for each 10-s interval (yes/no). Univariate and multivariate conditional regression models estimated the risk of unintentional leaks during an interval "T" based on the explanatory variables from the previous interval "T-1." A sensitivity analysis for the type of mask was then conducted. The univariate analysis showed that mandibular lowering (mouth opening), a high level of CPAP, body position (other than supine), and rapid eye movement (REM) sleep increased the risk of unintentional leaks and microarousal decreased it. In the multivariate analysis, the same variables remained independently associated with an increased risk of unintentional leakage. The sensitivity analysis showed that oronasal masks reduced the risk of unintentional leaks in cases of mouth opening and REM sleep. Mouth opening, CPAP level, sleep position, and REM sleep independently contribute to unintentional leakage. These results provide a strong rationale for the definition of phenotypes and the individual management of leaks during CPAP treatment. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  4. SeaWiFS technical report series. Volume 31: Stray light in the SeaWiFS radiometer

    NASA Technical Reports Server (NTRS)

    Hooker, Stanford B. (Editor); Firestone, Elaine R. (Editor); Acker, James G. (Editor); Barnes, Robert A.; Holmes, Alan W.; Esaias, Wayne E.

    1995-01-01

    Some of the measurements from the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) will not be useful as ocean measurements. For the ocean data set, there are procedures in place to mask the SeaWiFS measurements of clouds and ice. Land measurements will also be masked using a geographic technique based on each measurment's latitude and longitude. Each of these masks involves a source of light much brighter than the ocean. Because of stray light in the SeaWiFS radiometer, light from these bright sources can contaminate ocean measurements located a variable number of pixels away from a bright source. In this document, the sources of stray light in the sensor are examined, and a method is developed for masking measurements near bright targets for stray light effects. In addition, a procedure is proposed for reducing the effects of stray light in the flight data from SeaWiFS. This correction can also reduce the number of pixels masked for stray light. Without these corrections, local area scenes must be masked 10 pixels before and after bright targets in the along-scan direction. The addition of these corrections reduces the along-scan masks to four pixels before and after bright sources. In the along-track direction, the flight data are not corrected, and are masked two pixels before and after. Laboratory measurements have shown that stray light within the instrument changes in a direct ratio to the intensity of the bright source. The measurements have also shown that none of the bands show peculiarities in their stray light response. In other words, the instrument's response is uniform from band to band. The along-scan correction is based on each band's response to a 1 pixel wide bright sources. Since these results are based solely on preflight laboratory measurements, their successful implementation requires compliance with two additional criteria. First, since SeaWiFS has a large data volume, the correction and masking procedures must be such that they can be converted into computationally fast algorithms. Second, they must be shown to operate properly on flight data. The laboratory results, and the corrections and masking procedures that derive from them, should be considered as zeroeth order estimates of the effects that will be found on orbit.

  5. Respiratory source control using a surgical mask: An in vitro study

    PubMed Central

    Patel, Rajeev B.; Skaria, Shaji D.; Mansour, Mohamed M.; Smaldone, Gerald C.

    2016-01-01

    ABSTRACT Cough etiquette and respiratory hygiene are forms of source control encouraged to prevent the spread of respiratory infection. The use of surgical masks as a means of source control has not been quantified in terms of reducing exposure to others. We designed an in vitro model using various facepieces to assess their contribution to exposure reduction when worn at the infectious source (Source) relative to facepieces worn for primary (Receiver) protection, and the factors that contribute to each. In a chamber with various airflows, radiolabeled aerosols were exhaled via a ventilated soft-face manikin head using tidal breathing and cough (Source). Another manikin, containing a filter, quantified recipient exposure (Receiver). The natural fit surgical mask, fitted (SecureFit) surgical mask and an N95-class filtering facepiece respirator (commonly known as an “N95 respirator”) with and without a Vaseline-seal were tested. With cough, source control (mask or respirator on Source) was statistically superior to mask or unsealed respirator protection on the Receiver (Receiver protection) in all environments. To equal source control during coughing, the N95 respirator must be Vaseline-sealed. During tidal breathing, source control was comparable or superior to mask or respirator protection on the Receiver. Source control via surgical masks may be an important adjunct defense against the spread of respiratory infections. The fit of the mask or respirator, in combination with the airflow patterns in a given setting, are significant contributors to source control efficacy. Future clinical trials should include a surgical mask source control arm to assess the contribution of source control in overall protection against airborne infection. PMID:26225807

  6. Advances in low-defect multilayers for EUVL mask blanks

    NASA Astrophysics Data System (ADS)

    Folta, James A.; Davidson, J. Courtney; Larson, Cindy C.; Walton, Christopher C.; Kearney, Patrick A.

    2002-07-01

    Low-defect multilayer coatings are required to fabricate mask blanks for Extreme Ultraviolet Lithography (EUVL). The mask blanks consist of high reflectance EUV multilayers on low thermal expansion substrates. A defect density of 0.0025 printable defects/cm2 for both the mask substrate and the multilayer is required to provide a mask blank yield of 60 percent. Current low defect multilayer coating technology allows repeated coating-added defect levels of 0.05/cm2 for defects greater than 90 nm polystyrene latex sphere (PSL) equivalent size for lots of 20 substrates. Extended clean operation of the coating system at levels below 0.08/cm2 for 3 months of operation has also been achieved. Two substrates with zero added defects in the quality area have been fabricated, providing an existence proof that ultra low defect coatings are possible. Increasing the ion source-to-target distance from 410 to 560 mm to reduce undesired coating of the ion source caused the defect density to increase to 0.2/cm2. Deposition and etching diagnostic witness substrates and deposition pinhole cameras showed a much higher level of ion beam spillover (ions missing the sputter target) than expected. Future work will quantify beam spillover, and test designs to reduce spillover, if it is confirmed to be the cause of the increased defect level. The LDD system will also be upgraded to allow clean coating of standard format mask substrates. The upgrade will confirm that the low defect process developed on Si wafers is compatible with the standard mask format 152 mm square substrates, and will provide a clean supply of EUVL mask blanks needed to support development of EUVL mask patterning processes and clean mask handling technologies.

  7. Identification of optimal mask size parameter for noise filtering in 99mTc-methylene diphosphonate bone scintigraphy images.

    PubMed

    Pandey, Anil K; Bisht, Chandan S; Sharma, Param D; ArunRaj, Sreedharan Thankarajan; Taywade, Sameer; Patel, Chetan; Bal, Chandrashekhar; Kumar, Rakesh

    2017-11-01

    Tc-methylene diphosphonate (Tc-MDP) bone scintigraphy images have limited number of counts per pixel. A noise filtering method based on local statistics of the image produces better results than a linear filter. However, the mask size has a significant effect on image quality. In this study, we have identified the optimal mask size that yields a good smooth bone scan image. Forty four bone scan images were processed using mask sizes 3, 5, 7, 9, 11, 13, and 15 pixels. The input and processed images were reviewed in two steps. In the first step, the images were inspected and the mask sizes that produced images with significant loss of clinical details in comparison with the input image were excluded. In the second step, the image quality of the 40 sets of images (each set had input image, and its corresponding three processed images with 3, 5, and 7-pixel masks) was assessed by two nuclear medicine physicians. They selected one good smooth image from each set of images. The image quality was also assessed quantitatively with a line profile. Fisher's exact test was used to find statistically significant differences in image quality processed with 5 and 7-pixel mask at a 5% cut-off. A statistically significant difference was found between the image quality processed with 5 and 7-pixel mask at P=0.00528. The identified optimal mask size to produce a good smooth image was found to be 7 pixels. The best mask size for the John-Sen Lee filter was found to be 7×7 pixels, which yielded Tc-methylene diphosphonate bone scan images with the highest acceptable smoothness.

  8. Evaluation of Occupational Exposure of Glazers of a Ceramic Industry to Cobalt Blue Dye

    PubMed Central

    KARGAR, Fatemeh; SHAHTAHERI, Seyed Jamaleddin; GOLBABAEI, Farideh; BARKHORDARI, Abolfazl; RAHIMI-FROUSHANI, Abbas; KHADEM, Monireh

    2013-01-01

    Background: Cobalt is one of the most important constituent present in ceramic industries. Glazers are the relevant workers when they are producing blue colored ceramic, causing occupational exposure to such metal. Through this study, urinary cobalt was determined in glazers in a ceramic industry when they were producing blue-colored ceramic glazes. Methods: In this case-control study, spot urine samples were collected from 49 glazers at the start and end of work shifts (totally 98 samples) in 2011. Control group were well matched for age, height, and weight. A solid phase extraction system was used for separation and preconcentration of samples followed by analysis by inductively coupled plasma-atomic emission spectroscopy (ICP-AES). All participants filled out a self administered questionnaire comprises questions about duration of exposure, work shift, use of mask, skin dermatitis, kind of job, ventilation system, overtime work, age, weight, and height. The lung function tests were performed on each control and cobalt exposed subjects. Analysis of covariance (ANCOVA) was used to evaluate the obtained results. Results: Urinary levels of cobalt were significantly higher in the glazers compared to the control group. There were significant differences at urinary concentration of cobalt at the start and end of the work shift in glazers. Spirometric parameters were significantly lower in the glazers compared to the control group. Among the variables used in questionnaire the significant variables were dermatitis skin, mask, ventilation, and overtime work. Conclusion: This study verified existence of cobalt in the urine glazers, showing lower amount than the ACGIH standard. PMID:26056641

  9. Vector wavefront propagation modeling for the TPF coronagraph

    NASA Astrophysics Data System (ADS)

    Lieber, Michael D.; Neureuther, Andrew R.; Ceperley, Dan; Kasdin, N. Jeremy; Ter-Gabrielyan, Nikolay

    2004-10-01

    The TPF mission to search for exo-solar planets is extremely challenging both technically and from a performance modeling perspective. For the visible light coronagraph approach, the requirements for 1e10 rejection of star light to planet signal has not yet been achieved in laboratory testing and full-scale testing on the ground has many more obstacles and may not be possible. Therefore, end-to-end performance modeling will be relied upon to fully predict performance. One of the key technologies developed for achieving the rejection ratios uses shaped pupil masks to selectively cancel starlight in planet search regions by taking advantage of diffraction. Modeling results published to date have been based upon scalar wavefront propagation theory to compute the residual star and planet images. This ignores the 3D structure of the mask and the interaction of light with matter. In this paper we discuss previous work with a system model of the TPF coronagraph and propose an approach for coupling in a vector propagation model using the Finite Difference Time Domain (FDTD) method. This method, implemented in a software package called TEMPEST, allows us to propagate wavefronts through a mask structure to an integrated system model to explore the vector propagation aspects of the problem. We can then do rigorous mask scatter modeling to understand the effects of real physical mask structures on the magnitude, phase, polarization, and wavelength dependence of the transmitted light near edges. Shaped mask technology is reviewed, and computational aspects and interface issues to a TPF integrated system model are also discussed.

  10. Airway physical examination tests for detection of difficult airway management in apparently normal adult patients.

    PubMed

    Roth, Dominik; Pace, Nathan L; Lee, Anna; Hovhannisyan, Karen; Warenits, Alexandra-Maria; Arrich, Jasmin; Herkner, Harald

    2018-05-15

    The unanticipated difficult airway is a potentially life-threatening event during anaesthesia or acute conditions. An unsuccessfully managed upper airway is associated with serious morbidity and mortality. Several bedside screening tests are used in clinical practice to identify those at high risk of difficult airway. Their accuracy and benefit however, remains unclear. The objective of this review was to characterize and compare the diagnostic accuracy of the Mallampati classification and other commonly used airway examination tests for assessing the physical status of the airway in adult patients with no apparent anatomical airway abnormalities. We performed this individually for each of the four descriptors of the difficult airway: difficult face mask ventilation, difficult laryngoscopy, difficult tracheal intubation, and failed intubation. We searched major electronic databases including CENTRAL, MEDLINE, Embase, ISI Web of Science, CINAHL, as well as regional, subject specific, and dissertation and theses databases from inception to 16 December 2016, without language restrictions. In addition, we searched the Science Citation Index and checked the references of all the relevant studies. We also handsearched selected journals, conference proceedings, and relevant guidelines. We updated this search in March 2018, but we have not yet incorporated these results. We considered full-text diagnostic test accuracy studies of any individual index test, or a combination of tests, against a reference standard. Participants were adults without obvious airway abnormalities, who were having laryngoscopy performed with a standard laryngoscope and the trachea intubated with a standard tracheal tube. Index tests included the Mallampati test, modified Mallampati test, Wilson risk score, thyromental distance, sternomental distance, mouth opening test, upper lip bite test, or any combination of these. The target condition was difficult airway, with one of the following reference standards: difficult face mask ventilation, difficult laryngoscopy, difficult tracheal intubation, and failed intubation. We performed screening and selection of the studies, data extraction and assessment of methodological quality (using QUADAS-2) independently and in duplicate. We designed a Microsoft Access database for data collection and used Review Manager 5 and R for data analysis. For each index test and each reference standard, we assessed sensitivity and specificity. We produced forest plots and summary receiver operating characteristic (ROC) plots to summarize the data. Where possible, we performed meta-analyses to calculate pooled estimates and compare test accuracy indirectly using bivariate models. We investigated heterogeneity and performed sensitivity analyses. We included 133 (127 cohort type and 6 case-control) studies involving 844,206 participants. We evaluated a total of seven different prespecified index tests in the 133 studies, as well as 69 non-prespecified, and 32 combinations. For the prespecified index tests, we found six studies for the Mallampati test, 105 for the modified Mallampati test, six for the Wilson risk score, 52 for thyromental distance, 18 for sternomental distance, 34 for the mouth opening test, and 30 for the upper lip bite test. Difficult face mask ventilation was the reference standard in seven studies, difficult laryngoscopy in 92 studies, difficult tracheal intubation in 50 studies, and failed intubation in two studies. Across all studies, we judged the risk of bias to be variable for the different domains; we mostly observed low risk of bias for patient selection, flow and timing, and unclear risk of bias for reference standard and index test. Applicability concerns were generally low for all domains. For difficult laryngoscopy, the summary sensitivity ranged from 0.22 (95% confidence interval (CI) 0.13 to 0.33; mouth opening test) to 0.67 (95% CI 0.45 to 0.83; upper lip bite test) and the summary specificity ranged from 0.80 (95% CI 0.74 to 0.85; modified Mallampati test) to 0.95 (95% CI 0.88 to 0.98; Wilson risk score). The upper lip bite test for diagnosing difficult laryngoscopy provided the highest sensitivity compared to the other tests (P < 0.001). For difficult tracheal intubation, summary sensitivity ranged from 0.24 (95% CI 0.12 to 0.43; thyromental distance) to 0.51 (95% CI 0.40 to 0.61; modified Mallampati test) and the summary specificity ranged from 0.87 (95% CI 0.82 to 0.91; modified Mallampati test) to 0.93 (0.87 to 0.96; mouth opening test). The modified Mallampati test had the highest sensitivity for diagnosing difficult tracheal intubation compared to the other tests (P < 0.001). For difficult face mask ventilation, we could only estimate summary sensitivity (0.17, 95% CI 0.06 to 0.39) and specificity (0.90, 95% CI 0.81 to 0.95) for the modified Mallampati test. Bedside airway examination tests, for assessing the physical status of the airway in adults with no apparent anatomical airway abnormalities, are designed as screening tests. Screening tests are expected to have high sensitivities. We found that all investigated index tests had relatively low sensitivities with high variability. In contrast, specificities were consistently and markedly higher than sensitivities across all tests. The standard bedside airway examination tests should be interpreted with caution, as they do not appear to be good screening tests. Among the tests we examined, the upper lip bite test showed the most favourable diagnostic test accuracy properties. Given the paucity of available data, future research is needed to develop tests with high sensitivities to make them useful, and to consider their use for screening difficult face mask ventilation and failed intubation. The 27 studies in 'Studies awaiting classification' may alter the conclusions of the review, once we have assessed them.

  11. A randomised controlled trial on the effect of mask choice on residual respiratory events with continuous positive airway pressure treatment.

    PubMed

    Ebben, Matthew R; Narizhnaya, Mariya; Segal, Alan Z; Barone, Daniel; Krieger, Ana C

    2014-06-01

    It has been found that mask style can affect the amount of continuous positive airway pressure (CPAP) required to reduce an apnoea/hyponoea index (AHI) to < 5/h on a titration study. However, it was not previously known whether switching from one CPAP mask style to another post titration could affect the residual AHI with CPAP. The purpose of this study was to investigate the differences in residual AHI with CPAP treatment between oronasal and nasal masks. Twenty-one subjects (age mean (M)=62.9, body mass index (BMI) M=29.6 kg/m2) were randomised (14 subjects completed the protocol) to undergo an in-laboratory CPAP titration with either a nasal mask or an oronasal mask. Subjects were then assigned this mask for 3weeks of at-home CPAP use with the optimal treatment pressure determined on the laboratory study (CPAP M=8.4 cm of H2O). At the end of this 3-week period, data were collected from the CPAP machine and the subject was given the other mask to use with the same CPAP settings for the next 3weeks at home (if the nasal mask was given initially, the oronasal one was given later and vice versa). On completion of the second 3-week period, data on residual AHI were again collected and compared with the first 3-week period on CPAP. A Wilcoxon Signed-Rank Test (two-tailed) revealed that residual AHI with CPAP treatment was significantly higher with the oronasal compared with the nasal mask (z = -3.296, p<0.001). All 14 subjects had a higher residual AHI with the oronasal versus nasal mask, and 50% of the subjects had a residual AHI >10/h in the oronasal mask condition, even though all of these subjects were titrated to an AHI of < 5/h in the laboratory. A higher residual AHI was seen in all patients with the use of an oronasal mask compared with a nasal mask. Switching to an oronasal mask post titration results in an increase in residual AHI with CPAP treatment, and pressure adjustment may be warranted. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. More Realistic Face Model Surface Improves Relevance of Pediatric In-Vitro Aerosol Studies

    PubMed Central

    Amirav, Israel; Halamish, Asaf; Gorenberg, Miguel; Omar, Hamza; Newhouse, Michael T.

    2015-01-01

    Background Various hard face models are commonly used to evaluate the efficiency of aerosol face masks. Softer more realistic “face” surface materials, like skin, deform upon mask application and should provide more relevant in-vitro tests. Studies that simultaneously take into consideration many of the factors characteristic of the in vivo face are lacking. These include airways, various application forces, comparison of various devices, comparison with a hard-surface model and use of a more representative model face based on large numbers of actual faces. Aim To compare mask to “face” seal and aerosol delivery of two pediatric masks using a soft vs. a hard, appropriately representative, pediatric face model under various applied forces. Methods Two identical face models and upper airways replicas were constructed, the only difference being the suppleness and compressibility of the surface layer of the “face.” Integrity of the seal and aerosol delivery of two different masks [AeroChamber (AC) and SootherMask (SM)] were compared using a breath simulator, filter collection and realistic applied forces. Results The soft “face” significantly increased the delivery efficiency and the sealing characteristics of both masks. Aerosol delivery with the soft “face” was significantly greater for the SM compared to the AC (p< 0.01). No statistically significant difference between the two masks was observed with the hard “face.” Conclusions The material and pliability of the model “face” surface has a significant influence on both the seal and delivery efficiency of face masks. This finding should be taken into account during in-vitro aerosol studies. PMID:26090661

  13. Electrically induced formation of uncapped, hollow polymeric microstructures

    NASA Astrophysics Data System (ADS)

    Lee, Sung Hun; Kim, Pilnam; Jeong, Hoon Eui; Suh, Kahp Y.

    2006-11-01

    Uncapped, hollow polymeric microstructures were fabricated on a silicon substrate using electric field induced stretching and detachment. Initially, square or cylinder microposts were generated using a solvent-assisted capillary molding technique, and a featureless electrode mask was positioned on the top of the microstructure with spacers maintaining an air gap (~20 µm). Upon exposure to an external electric field (1.0-3.0 V µm-1), the hollow microstructures were destabilized and stretched by the well-known electrohydrodynamic instability, resulting in contact of the top polymer surface with the mask. Subsequently, detachment of the capping layer occurred upon removal of the mask due to larger adhesion forces at the polymer/mask interface than cohesion forces of the polymer. These hollow microstructures were tested to capture the budding yeast, Saccharomyces cerevisiae, for shear protection.

  14. The effects of energetic and informational masking on The Words-in-Noise Test (WIN).

    PubMed

    Wilson, Richard H; Trivette, Cristine P; Williams, Daniel A; Watts, Kelly L

    2012-01-01

    In certain masking paradigms, the masker can have two components, energetic and informational. Energetic masking is the traditional peripheral masking, whereas informational masking involves confusions (uncertainty) between the signal and masker that originate more centrally in the auditory system. Sperry et al (1997) used Northwestern University Auditory Test No. 6 (NU-6) words in multitalker babble to study the differential effects of energetic and informational masking using babble played temporally forward (FB) and backward (BB). The FB and BB are the same except BB is void of the contextual and semantic content cues that are available in FB. It is these informational cues that are thought to fuel informational masking. Sperry et al found 15% better recognition performance (∼3 dB) on BB than on FB, which can be interpreted as the presence of informational masking in the FB condition and not in the BB condition (Dirks and Bower, 1969). The Words-in-Noise Test (WIN) (Wilson, 2003; Wilson and McArdle, 2007) uses NU-6 words as the signal and multitalker babble as the masker, which is a combination of stimuli that potentially could produce informational masking. The WIN presents 5 or 10 words at each of seven signal-to-noise ratios (S/N, SNR) from 24 to 0 dB in 4 dB decrements with the 50% correct point being the metric of interest. The same recordings of the NU-6 words and multitalker babble used by Sperry et al are used in the WIN. To determine whether informational masking was involved with the WIN. Descriptive, quasi-experimental designs were conducted in three experiments using FB and BB in various paradigms in which FB and BB varied from 4.3 sec concatenated segments to essentially continuous. Eighty young adults with normal hearing and 64 older adults with sensorineural hearing losses participated in a series of three experiments. Experiment 1 compared performance on the normal WIN (FB) with performance on the WIN in which the babble segment with each word was reversed temporally (BB). Experiment 2 examined the effects of continuous FB and BB segments on WIN performance. Experiment 3 replicated the Sperry et al (1997) experiment at 4 and 0 dB S/N using NU-6 words in the FB and BB conditions. Experiment 1-with the WIN paradigm, recognition performances on FB and BB were the same for listeners with normal hearing and listeners with hearing loss, except at the 0 dB S/N with the listeners with normal hearing at which performance was significantly better on BB than FB. Experiment 2-recognition performances on FB and BB were the same at all SNRs for listeners with normal hearing using a slightly modified WIN paradigm. Experiment 3-there was no difference in performances on the FB and BB conditions with either of the two SNRs. Informational masking was not involved in the WIN paradigm. The Sperry et al results were not replicated, which is thought to be related to the way in which the Sperry et al BB condition was produced. American Academy of Audiology.

  15. Relating binocular and monocular vision in strabismic and anisometropic amblyopia.

    PubMed

    Agrawal, Ritwick; Conner, Ian P; Odom, J V; Schwartz, Terry L; Mendola, Janine D

    2006-06-01

    To examine deficits in monocular and binocular vision in adults with amblyopia and to test the following 2 hypotheses: (1) Regardless of clinical subtype, the degree of impairment in binocular integration predicts the pattern of monocular acuity deficits. (2) Subjects who lack binocular integration exhibit the most severe interocular suppression. Seven subjects with anisometropia, 6 subjects with strabismus, and 7 control subjects were tested. Monocular tests included Snellen acuity, grating acuity, Vernier acuity, and contrast sensitivity. Binocular tests included Titmus stereo test, binocular motion integration, and dichoptic contrast masking. As expected, both groups showed deficits in monocular acuity, with subjects with strabismus showing greater deficits in Vernier acuity. Both amblyopic groups were then characterized according to the degree of residual stereoacuity and binocular motion integration ability, and 67% of subjects with strabismus compared with 29% of subjects with anisometropia were classified as having "nonbinocular" vision according to our criterion. For this nonbinocular group, Vernier acuity is most impaired. In addition, the nonbinocular group showed the most dichoptic contrast masking of the amblyopic eye and the least dichoptic contrast masking of the fellow eye. The degree of residual binocularity and interocular suppression predicts monocular acuity and may be a significant etiological mechanism of vision loss.

  16. Performance testing and results of the first Etec CORE-2564

    NASA Astrophysics Data System (ADS)

    Franks, C. Edward; Shikata, Asao; Baker, Catherine A.

    1993-03-01

    In order to be able to write 64 megabit DRAM reticles, to prepare to write 256 megabit DRAM reticles and in general to meet the current and next generation mask and reticle quality requirements, Hoya Micro Mask (HMM) installed in 1991 the first CORE-2564 Laser Reticle Writer from Etec Systems, Inc. The system was delivered as a CORE-2500XP and was subsequently upgraded to a 2564. The CORE (Custom Optical Reticle Engraver) system produces photomasks with an exposure strategy similar to that employed by an electron beam system, but it uses a laser beam to deliver the photoresist exposure energy. Since then the 2564 has been tested by Etec's standard Acceptance Test Procedure and by several supplementary HMM techniques to insure performance to all the Etec advertised specifications and certain additional HMM requirements that were more demanding and/or more thorough than the advertised specifications. The primary purpose of the HMM tests was to more closely duplicate mask usage. The performance aspects covered by the tests include registration accuracy and repeatability; linewidth accuracy, uniformity and linearity; stripe butting; stripe and scan linearity; edge quality; system cleanliness; minimum geometry resolution; minimum address size and plate loading accuracy and repeatability.

  17. Relationship Among Signal Fidelity, Hearing Loss, and Working Memory for Digital Noise Suppression.

    PubMed

    Arehart, Kathryn; Souza, Pamela; Kates, James; Lunner, Thomas; Pedersen, Michael Syskind

    2015-01-01

    This study considered speech modified by additive babble combined with noise-suppression processing. The purpose was to determine the relative importance of the signal modifications, individual peripheral hearing loss, and individual cognitive capacity on speech intelligibility and speech quality. The participant group consisted of 31 individuals with moderate high-frequency hearing loss ranging in age from 51 to 89 years (mean = 69.6 years). Speech intelligibility and speech quality were measured using low-context sentences presented in babble at several signal-to-noise ratios. Speech stimuli were processed with a binary mask noise-suppression strategy with systematic manipulations of two parameters (error rate and attenuation values). The cumulative effects of signal modification produced by babble and signal processing were quantified using an envelope-distortion metric. Working memory capacity was assessed with a reading span test. Analysis of variance was used to determine the effects of signal processing parameters on perceptual scores. Hierarchical linear modeling was used to determine the role of degree of hearing loss and working memory capacity in individual listener response to the processed noisy speech. The model also considered improvements in envelope fidelity caused by the binary mask and the degradations to envelope caused by error and noise. The participants showed significant benefits in terms of intelligibility scores and quality ratings for noisy speech processed by the ideal binary mask noise-suppression strategy. This benefit was observed across a range of signal-to-noise ratios and persisted when up to a 30% error rate was introduced into the processing. Average intelligibility scores and average quality ratings were well predicted by an objective metric of envelope fidelity. Degree of hearing loss and working memory capacity were significant factors in explaining individual listener's intelligibility scores for binary mask processing applied to speech in babble. Degree of hearing loss and working memory capacity did not predict listeners' quality ratings. The results indicate that envelope fidelity is a primary factor in determining the combined effects of noise and binary mask processing for intelligibility and quality of speech presented in babble noise. Degree of hearing loss and working memory capacity are significant factors in explaining variability in listeners' speech intelligibility scores but not in quality ratings.

  18. Some considerations in evaluating spoken word recognition by normal-hearing, noise-masked normal-hearing, and cochlear implant listeners. I: The effects of response format.

    PubMed

    Sommers, M S; Kirk, K I; Pisoni, D B

    1997-04-01

    The purpose of the present studies was to assess the validity of using closed-set response formats to measure two cognitive processes essential for recognizing spoken words---perceptual normalization (the ability to accommodate acoustic-phonetic variability) and lexical discrimination (the ability to isolate words in the mental lexicon). In addition, the experiments were designed to examine the effects of response format on evaluation of these two abilities in normal-hearing (NH), noise-masked normal-hearing (NMNH), and cochlear implant (CI) subject populations. The speech recognition performance of NH, NMNH, and CI listeners was measured using both open- and closed-set response formats under a number of experimental conditions. To assess talker normalization abilities, identification scores for words produced by a single talker were compared with recognition performance for items produced by multiple talkers. To examine lexical discrimination, performance for words that are phonetically similar to many other words (hard words) was compared with scores for items with few phonetically similar competitors (easy words). Open-set word identification for all subjects was significantly poorer when stimuli were produced in lists with multiple talkers compared with conditions in which all of the words were spoken by a single talker. Open-set word recognition also was better for lexically easy compared with lexically hard words. Closed-set tests, in contrast, failed to reveal the effects of either talker variability or lexical difficulty even when the response alternatives provided were systematically selected to maximize confusability with target items. These findings suggest that, although closed-set tests may provide important information for clinical assessment of speech perception, they may not adequately evaluate a number of cognitive processes that are necessary for recognizing spoken words. The parallel results obtained across all subject groups indicate that NH, NMNH, and CI listeners engage similar perceptual operations to identify spoken words. Implications of these findings for the design of new test batteries that can provide comprehensive evaluations of the individual capacities needed for processing spoken language are discussed.

  19. 77 FR 49412 - Takes of Marine Mammals Incidental to Specified Activities; Navy Research, Development, Test and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-16

    ...; high-pitched sounds contain high frequencies and low-pitched sounds contain low frequencies. Natural... estimated to occur between approximately 150 Hz and 160 kHz. High-frequency cetaceans (eight species of true... masking by high frequency sound. Human data indicate low-frequency sound can mask high-frequency sounds (i...

  20. Does the Mean Score Mask Poor Delivery of Educational Services in School Effectiveness Ratings?

    ERIC Educational Resources Information Center

    Lang, Michael H.; And Others

    This study investigated whether mean scores in school effectiveness ratings were masking poor delivery of educational services to low achievers in a sample of 242 Louisiana public elementary schools accounting for over 18,000 third graders tested in 1989. Ten separate multiple regression models, each producing studentized residuals used as school…

  1. Development of Spatial Release from Masking in Mandarin-Speaking Children with Normal Hearing

    ERIC Educational Resources Information Center

    Yuen, Kevin C. P.; Yuan, Meng

    2014-01-01

    Purpose: This study investigated the development of spatial release from masking in children using closed-set Mandarin disyllabic words and monosyllabic words carrying lexical tones as test stimuli and speech spectrum-weighted noise as a masker. Method: Twenty-six children ages 4-9 years and 12 adults, all with normal hearing, participated in…

  2. Dissociating Consciousness from Inhibitory Control: Evidence for Unconsciously Triggered Response Inhibition in the Stop-Signal Task

    ERIC Educational Resources Information Center

    van Gaal, Simon; Ridderinkhof, K. Richard; van den Wildenberg, Wery P. M.; Lamme, Victor A. F.

    2009-01-01

    Theories about the functional relevance of consciousness commonly posit that higher order cognitive control functions, such as response inhibition, require consciousness. To test this assertion, the authors designed a masked stop-signal paradigm to examine whether response inhibition could be triggered and initiated by masked stop signals, which…

  3. Feedforward and Feedback Control in Apraxia of Speech: Effects of Noise Masking on Vowel Production

    ERIC Educational Resources Information Center

    Maas, Edwin; Mailend, Marja-Liisa; Guenther, Frank H.

    2015-01-01

    Purpose: This study was designed to test two hypotheses about apraxia of speech (AOS) derived from the Directions Into Velocities of Articulators (DIVA) model (Guenther et al., 2006): the feedforward system deficit hypothesis and the feedback system deficit hypothesis. Method: The authors used noise masking to minimize auditory feedback during…

  4. Evidence for differential modulation of primary and nonprimary auditory cortex by forward masking in tinnitus.

    PubMed

    Roberts, Larry E; Bosnyak, Daniel J; Bruce, Ian C; Gander, Phillip E; Paul, Brandon T

    2015-09-01

    It has been proposed that tinnitus is generated by aberrant neural activity that develops among neurons in tonotopic of regions of primary auditory cortex (A1) affected by hearing loss, which is also the frequency region where tinnitus percepts localize (Eggermont and Roberts 2004; Roberts et al., 2010, 2013). These models suggest (1) that differences between tinnitus and control groups of similar age and audiometric function should depend on whether A1 is probed in tinnitus frequency region (TFR) or below it, and (2) that brain responses evoked from A1 should track changes in the tinnitus percept when residual inhibition (RI) is induced by forward masking. We tested these predictions by measuring (128-channel EEG) the sound-evoked 40-Hz auditory steady-state response (ASSR) known to localize tonotopically to neural sources in A1. For comparison the N1 transient response localizing to distributed neural sources in nonprimary cortex (A2) was also studied. When tested under baseline conditions where tinnitus subjects would have heard their tinnitus, ASSR responses were larger in a tinnitus group than in controls when evoked by 500 Hz probes while the reverse was true for tinnitus and control groups tested with 5 kHz probes, confirming frequency-dependent group differences in this measure. On subsequent trials where RI was induced by masking (narrow band noise centered at 5 kHz), ASSR amplitude increased in the tinnitus group probed at 5 kHz but not in the tinnitus group probed at 500 Hz. When collapsed into a single sample tinnitus subjects reporting comparatively greater RI depth and duration showed comparatively larger ASSR increases after masking regardless of probe frequency. Effects of masking on ASSR amplitude in the control groups were completely reversed from those in the tinnitus groups, with no change seen to 5 kHz probes but ASSR increases to 500 Hz probes even though the masking sound contained no energy at 500 Hz (an "off-frequency" masking effect). In contrast to these findings for the ASSR, N1 amplitude was larger in tinnitus than control groups at both probe frequencies under baseline conditions, decreased after masking in all conditions, and did not relate to RI. These results suggest that aberrant neural activity occurring in the TFR of A1 underlies tinnitus and its modulation during RI. They indicate further that while neural changes occur in A2 in tinnitus, these changes do not reflect the tinnitus percept. Models for tinnitus and forward masking are described that integrate these findings within a common framework. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  5. Mask Ventilation during Induction of General Anesthesia: Influences of Obstructive Sleep Apnea.

    PubMed

    Sato, Shin; Hasegawa, Makoto; Okuyama, Megumi; Okazaki, Junko; Kitamura, Yuji; Sato, Yumi; Ishikawa, Teruhiko; Sato, Yasunori; Isono, Shiroh

    2017-01-01

    Depending on upper airway patency during anesthesia induction, tidal volume achieved by mask ventilation may vary. In 80 adult patients undergoing general anesthesia, the authors tested a hypothesis that tidal volume during mask ventilation is smaller in patients with sleep-disordered breathing priorly defined as apnea hypopnea index greater than 5 per hour. One-hand mask ventilation with a constant ventilator setting (pressure-controlled ventilation) was started 20 s after injection of rocuronium and maintained for 1 min during anesthesia induction. Mask ventilation efficiency was assessed by the breath number needed to initially exceed 5 ml/kg ideal body weight of expiratory tidal volume (primary outcome) and tidal volumes (secondary outcomes) during initial 15 breaths (UMIN000012494). Tidal volume progressively increased by more than 70% in 1 min and did not differ between sleep-disordered breathing (n = 42) and non-sleep-disordered breathing (n = 38) patients. In post hoc subgroup analyses, the primary outcome breath number (mean [95% CI], 5.7 [4.1 to 7.3] vs. 1.7 [0.2 to 3.2] breath; P = 0.001) and mean tidal volume (6.5 [4.6 to 8.3] vs. 9.6 [7.7 to 11.4] ml/kg ideal body weight; P = 0.032) were significantly smaller in 20 sleep-disordered breathing patients with higher apnea hypopnea index (median [25th to 75th percentile]: 21.7 [17.6 to 31] per hour) than in 20 non-sleep disordered breathing subjects with lower apnea hypopnea index (1.0 [0.3 to 1.5] per hour). Obesity and occurrence of expiratory flow limitation during one-hand mask ventilation independently explained the reduction of efficiency of mask ventilation, while the use of two hands effectively normalized inefficient mask ventilation during one-hand mask ventilation. One-hand mask ventilation is difficult in patients with obesity and severe sleep-disordered breathing particularly when expiratory flow limitation occurs during mask ventilation.

  6. Accurate GM atrophy quantification in MS using lesion-filling with co-registered 2D lesion masks☆

    PubMed Central

    Popescu, V.; Ran, N.C.G.; Barkhof, F.; Chard, D.T.; Wheeler-Kingshott, C.A.; Vrenken, H.

    2014-01-01

    Background In multiple sclerosis (MS), brain atrophy quantification is affected by white matter lesions. LEAP and FSL-lesion_filling, replace lesion voxels with white matter intensities; however, they require precise lesion identification on 3DT1-images. Aim To determine whether 2DT2 lesion masks co-registered to 3DT1 images, yield grey and white matter volumes comparable to precise lesion masks. Methods 2DT2 lesion masks were linearly co-registered to 20 3DT1-images of MS patients, with nearest-neighbor (NNI), and tri-linear interpolation. As gold-standard, lesion masks were manually outlined on 3DT1-images. LEAP and FSL-lesion_filling were applied with each lesion mask. Grey (GM) and white matter (WM) volumes were quantified with FSL-FAST, and deep gray matter (DGM) volumes using FSL-FIRST. Volumes were compared between lesion mask types using paired Wilcoxon tests. Results Lesion-filling with gold-standard lesion masks compared to native images reduced GM overestimation by 1.93 mL (p < .001) for LEAP, and 1.21 mL (p = .002) for FSL-lesion_filling. Similar effects were achieved with NNI lesion masks from 2DT2. Global WM underestimation was not significantly influenced. GM and WM volumes from NNI, did not differ significantly from gold-standard. GM segmentation differed between lesion masks in the lesion area, and also elsewhere. Using the gold-standard, FSL-FAST quantified as GM on average 0.4% of the lesion area with LEAP and 24.5% with FSL-lesion_filling. Lesion-filling did not influence DGM volumes from FSL-FIRST. Discussion These results demonstrate that for global GM volumetry, precise lesion masks on 3DT1 images can be replaced by co-registered 2DT2 lesion masks. This makes lesion-filling a feasible method for GM atrophy measurements in MS. PMID:24567908

  7. Accelerated radiation damage testing of x-ray mask membrane materials

    NASA Astrophysics Data System (ADS)

    Seese, Philip A.; Cummings, Kevin D.; Resnick, Douglas J.; Yanof, Arnold W.; Johnson, William A.; Wells, Gregory M.; Wallace, John P.

    1993-06-01

    An accelerated test method and resulting metrology data are presented to show the effects of x- ray radiation on various x-ray mask membrane materials. A focused x-ray beam effectively reduces the radiation time to 1/5 of that required by normal exposure beam flux. Absolute image displacement results determined by this method indicate imperceptible movement for boron-doped silicon and silicon carbide membranes at a total incident dose of 500 KJ/cm2, while image displacement for diamond is 50 nm at 150 KJ/cm2 and silicon nitride is 70 nm at 36 KJ/cm2. Studies of temperature rise during the radiation test and effects of the high flux radiation, i.e., reciprocity tests, demonstrate the validity of this test method.

  8. Masked priming effect reflects evidence accumulated by the prime.

    PubMed

    Kinoshita, Sachiko; Norris, Dennis

    2010-01-01

    In the same-different match task, masked priming is observed with the same responses but not different responses. Norris and Kinoshita's (2008) Bayesian reader account of masked priming explains this pattern based on the same principle as that explaining the absence of priming for nonwords in the lexical decision task. The pattern of priming follows from the way the model makes optimal decisions in the two tasks; priming does not depend on first activating the prime and then the target. An alternative explanation is in terms of a bias towards responding "same" that exactly counters the facilitatory effect of lexical access. The present study tested these two views by varying both the degree to which the prime predicts the response and the visibility of the prime. Unmasked primes produced effects expected from the view that priming is influenced by the degree to which the prime predicts the response. In contrast, with masked primes, the size of priming for the same response was completely unaffected by predictability. These results rule out response bias as an explanation of the absence of masked priming for different responses and, in turn, indicate that masked priming is not a consequence of automatic lexical access of the prime.

  9. A Parallel Vector Machine for the PM Programming Language

    NASA Astrophysics Data System (ADS)

    Bellerby, Tim

    2016-04-01

    PM is a new programming language which aims to make the writing of computational geoscience models on parallel hardware accessible to scientists who are not themselves expert parallel programmers. It is based around the concept of communicating operators: language constructs that enable variables local to a single invocation of a parallelised loop to be viewed as if they were arrays spanning the entire loop domain. This mechanism enables different loop invocations (which may or may not be executing on different processors) to exchange information in a manner that extends the successful Communicating Sequential Processes idiom from single messages to collective communication. Communicating operators avoid the additional synchronisation mechanisms, such as atomic variables, required when programming using the Partitioned Global Address Space (PGAS) paradigm. Using a single loop invocation as the fundamental unit of concurrency enables PM to uniformly represent different levels of parallelism from vector operations through shared memory systems to distributed grids. This paper describes an implementation of PM based on a vectorised virtual machine. On a single processor node, concurrent operations are implemented using masked vector operations. Virtual machine instructions operate on vectors of values and may be unmasked, masked using a Boolean field, or masked using an array of active vector cell locations. Conditional structures (such as if-then-else or while statement implementations) calculate and apply masks to the operations they control. A shift in mask representation from Boolean to location-list occurs when active locations become sufficiently sparse. Parallel loops unfold data structures (or vectors of data structures for nested loops) into vectors of values that may additionally be distributed over multiple computational nodes and then split into micro-threads compatible with the size of the local cache. Inter-node communication is accomplished using standard OpenMP and MPI. Performance analyses of the PM vector machine, demonstrating its scaling properties with respect to domain size and the number of processor nodes will be presented for a range of hardware configurations. The PM software and language definition are being made available under unrestrictive MIT and Creative Commons Attribution licenses respectively: www.pm-lang.org.

  10. Reliability of measuring half-cycle cervical range of motion may be increased using a spirit level for calibration.

    PubMed

    Wilke, Jan; Niederer, Daniel; Vogt, Lutz; Banzer, Winfried

    2018-02-01

    Assessments of range of motion (ROM) represent an essential part of clinical diagnostics. Ultrasonic movement analyses have been demonstrated to provide reliable results when analyzing complete amplitudes (e.g., flexion-extension). However, due to subjective determination of the starting position, the assessment of half-cycle movements (e.g, flexion only) is less reproducible. The present study aimed to examine the reliability of measuring half-cycle cervical ROM using a spirit level for calibration. 20 healthy subjects (30 ± 12yrs, 7♂, 13♀) participated in the randomized, controlled, cross-over trial. In two testing sessions with one week of wash-out in between, cervical ROM was measured by means of an ultrasonic 3D movement analysis system using a test-retest design (baseline and 5 min post baseline). The sessions differed with reference to the mask carrying the ultrasound markers. It was removed during the 5 min break (mask off) or not (mask on). To determine the resting position, a bull's eye spirit level was used in each measurement. With ICC values of 0.90-0.98 (mask on, p < 0.001) and 0.90 to 0.97 (mask off, p < 0.001), both examined conditions demonstrated excellent test-retest reliability for separating the cycles regarding all movement planes. Cervical ROM during half-cycle movements can be assessed with excellent reliability using a spirit level. In contrast to subjective determination of the starting position, analyzing complete movement planes does not increase reliability. Using a defined and objective zero positioning allows the evaluation of repositioning tasks. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Temperature profiles of patient-applied eyelid warming therapies.

    PubMed

    Wang, Michael T M; Gokul, Akilesh; Craig, Jennifer P

    2015-12-01

    To compare temperature profile characteristics (on and off eye) of two patient-applied heat therapies for meibomian gland dysfunction (MGD): an eye mask containing disposable warming units (EyeGiene(®)) and a microwave-heated flaxseed eye bag(®) (MGDRx EyeBag(®)). In vitro evaluation: surface temperature profiles of activated eye masks and heated eye bags(®) (both n=10), were tracked every 10s until return to ambient temperature. Heat-transfer assessment: outer and inner eyelid temperature profiles throughout the eye mask and eye bag(®) treatment application period (10min) were investigated in triplicate. The devices were applied for 12 different time intervals in a randomised order, with a cool-down period in between to ensure ocular temperatures returned to baseline. Temperature measurements were taken before and immediately after each application. In vitro evaluation: on profile, the eye bag(®) surface temperature peaked earlier (0±0 s vs. 100±20 s, p<0.001), cooled more slowly and displayed less variability than the eye mask (all p<0.05). Heat-transfer assessment: the eye bag(®) effected higher peak inner eyelid temperatures (38.1±0.4°C vs. 37.4±0.2°C, p=0.04), as well as larger inner eyelid temperature increases over the first 2 min, and between 9 and 10 min (all p<0.05). The eye bag(®) surface temperature profile displayed greater uniformity and slower cooling than the eye mask, and was demonstrated to be significantly more effective in raising ocular temperatures than the eye mask, both statistically and clinically. This has implications for MGD treatment, where the melting points of meibomian secretions are likely to be higher with increasing disease severity. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Psychometric functions for informational masking

    NASA Astrophysics Data System (ADS)

    Lutfi, Robert A.; Kistler, Doris J.; Callahan, Michael R.; Wightman, Frederic L.

    2003-12-01

    The term informational masking has traditionally been used to refer to elevations in signal threshold resulting from masker uncertainty. In the present study, the method of constant stimuli was used to obtain complete psychometric functions (PFs) from 44 normal-hearing listeners in conditions known to produce varying amounts of informational masking. The listener's task was to detect a pure-tone signal in the presence of a broadband noise masker (low masker uncertainty) and in the presence of multitone maskers with frequencies and amplitudes that varied at random from one presentation to the next (high masker uncertainty). Relative to the broadband noise condition, significant reductions were observed in both the slope and the upper asymptote of the PF for multitone maskers producing large amounts of informational masking. Slope was affected more for some listeners and conditions while asymptote was affected more for others; consequently, neither parameter alone was highly predictive of individual thresholds or the amount of informational masking. Mean slopes and asymptotes varied nonmonotonically with the number of masker components in a manner similar to mean thresholds, particularly when the estimated effect of energetic masking on thresholds was subtracted out. As in past studies, the threshold data were well described by a model in which trial-by-trial judgments are based on a weighted sum of levels in dB at the output of independent auditory filters. The psychometric data, however, complicated the model's interpretation in two ways: First, they suggested that, depending on the listener and condition, the weights can either reflect a fixed influence of masker components on each trial or the effect of occasionally mistaking a masker component for the signal from trial to trial. Second, they indicated that in either case the variance of the underlying decision variable as estimated from PF slope is not by itself great enough to account for the observed changes in informational masking.

  13. Real-Time Functional Magnetic Resonance Imaging Amygdala Neurofeedback Changes Positive Information Processing in Major Depressive Disorder.

    PubMed

    Young, Kymberly D; Misaki, Masaya; Harmer, Catherine J; Victor, Teresa; Zotev, Vadim; Phillips, Raquel; Siegle, Greg J; Drevets, Wayne C; Bodurka, Jerzy

    2017-10-15

    In participants with major depressive disorder who are trained to upregulate their amygdalar hemodynamic responses during positive autobiographical memory recall with real-time functional magnetic resonance imaging neurofeedback (rtfMRI-nf) training, depressive symptoms diminish. This study tested whether amygdalar rtfMRI-nf also changes emotional processing of positive and negative stimuli in a variety of behavioral and imaging tasks. Patients with major depressive disorder completed two rtfMRI-nf sessions (18 received amygdalar rtfMRI-nf, 16 received control parietal rtfMRI-nf). One week before and following rtfMRI-nf training, participants performed tasks measuring responses to emotionally valenced stimuli including a backward-masking task, which measures the amygdalar hemodynamic response to emotional faces presented for traditionally subliminal duration and followed by a mask, and the Emotional Test Battery in which reaction times and performance accuracy are measured during tasks involving emotional faces and words. During the backward-masking task, amygdalar responses increased while viewing masked happy faces but decreased to masked sad faces in the experimental versus control group following rtfMRI-nf. During the Emotional Test Battery, reaction times decreased to identification of positive faces and during self-identification with positive words and vigilance scores increased to positive faces and decreased to negative faces during the faces dot-probe task in the experimental versus control group following rtfMRI-nf. rtfMRI-nf training to increase the amygdalar hemodynamic response to positive memories was associated with changes in amygdalar responses to happy and sad faces and improved processing of positive stimuli during performance of the Emotional Test Battery. These results may suggest that amygdalar rtfMRI-nf training alters responses to emotional stimuli in a manner similar to antidepressant pharmacotherapy. Copyright © 2017 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.

  14. Experimental verification of PSM polarimetry: monitoring polarization at 193nm high-NA with phase shift masks

    NASA Astrophysics Data System (ADS)

    McIntyre, Gregory; Neureuther, Andrew; Slonaker, Steve; Vellanki, Venu; Reynolds, Patrick

    2006-03-01

    The initial experimental verification of a polarization monitoring technique is presented. A series of phase shifting mask patterns produce polarization dependent signals in photoresist and are capable of monitoring the Stokes parameters of any arbitrary illumination scheme. Experiments on two test reticles have been conducted. The first reticle consisted of a series of radial phase gratings (RPG) and employed special apertures to select particular illumination angles. Measurement sensitivities of about 0.3 percent of the clear field per percent change in polarization state were observed. The second test reticle employed the more sensitive proximity effect polarization analyzers (PEPA), a more robust experimental setup, and a backside pinhole layer for illumination angle selection and to enable characterization of the full illuminator. Despite an initial complication with the backside pinhole alignment, the results correlate with theory. Theory suggests that, once the pinhole alignment is corrected in the near future, the second reticle should achieve a measurement sensitivity of about 1 percent of the clear field per percent change in polarization state. This corresponds to a measurement of the Stokes parameters after test mask calibration, to within about 0.02 to 0.03. Various potential improvements to the design, fabrication of the mask, and experimental setup are discussed. Additionally, to decrease measurement time, a design modification and double exposure technique is proposed to enable electrical detection of the measurement signal.

  15. The Effect of Oral Dexmedetomidine Premedication on Preoperative Cooperation and Emergence Delirium in Children Undergoing Dental Procedures.

    PubMed

    Keles, Sultan; Kocaturk, Ozlem

    2017-01-01

    The aim of this study was to detect the effect of 1  μ g/kg of oral dexmedetomidine (DEX) as premedication among children undergoing dental procedures. The study involved 100 children between 2 and 6 years of age, ASA I, who underwent full-mouth dental rehabilitation. The DEX group ( n = 50) received 1  μ g/kg DEX in apple juice, and the control group ( n = 50) received only apple juice. The patients' scores on the Ramsay Sedation Scale (RSS), parental separation anxiety scale, mask acceptance scale, and pediatric anesthesia emergence delirium scale (PAEDS) and hemodynamic parameters were recorded. The data were analyzed using chi-square test, Fisher's exact test, Student's t -test, and analysis of variance in SPSS. RSS scores were significantly higher in the DEX group than group C at 15, 30, and 45 min ( p < 0.05). More children (68% easy separation, 74% satisfactory mask acceptance) in the DEX group showed satisfactory ease of parental separation and mask acceptance behavior ( p < 0.05). There was no significant difference in the PAEDS scores and mean hemodynamic parameters of both groups. Oral DEX administered at 1  μ g/kg provided satisfactory sedation levels, ease of parental separation, and mask acceptance in children but was not effective in preventing emergence delirium. The trial was registered (Protocol Registration Receipt NCT03174678) at clinicaltrials.gov.

  16. [Respiratory protection provided by N95 filtering facepiece respirators and disposable medicine masks against airborne bacteria in different working environments].

    PubMed

    Lu, W; Zhu, X C; Zhang, X Y; Chen, Y T; Chen, W H

    2016-09-20

    Objective: To determine the relative protection provided by N95 filtering facepiece respirators (FFR) and disposable medicine masks (DMM) against airborne bacteria in different working environments. Methods: The field study was performed with 12 subjects wearing an N95 filtering facepiece respirator and a disposable medicine mask for 1h, respectively. Airborne microorganisms and bacteria samples from both the external (Ce) and the inner (Ci) surface of N95 FFR and DMM are collected. The Ce: Ci ratio was used to calculate the bacterial filtering proportion. Bacterial filtering efficiency (BFE) was measured using the JWL-2A Sampler. Results: The bacterial filtration efficiency of N95 FFR and DMM were 99.93% and 91.53%, respectively. There was significant difference between the two materials ( P <0.05). In summer, airborne bacterial concentration was higher than that in winter. In the same season, airborne bacterial concentration in hospital environment is higher than that in campus. The higher the airborne bacterial concentration, the greater bacterial contaminated on the external surface of the used masks. To all masks used in different working environment, bacterial contamination on the external surface was much greater than the inner surface ( P <0.01). Compared to N95 FFR, DMM had slighter bacterial contamination on the external surface and greater bacterial contamination on the inner surface. However, this difference was not significant ( P >0.05). The bacterial filtering proportion of N95 FFR is higher than DMM. These differences were significant in samples tested in summer ( P <0.05) , but were not significant in samples tested in winter ( P >0.05). Conclusion: Bacterial filtering efficiency of N95 respirator is superior to medicine mask, and this advantage become more obvious in high airborne bacterial concentration levels.

  17. Filter quality of electret masks in filtering 14.6–594 nm aerosol particles: Effects of five decontamination methods

    PubMed Central

    Lin, Tzu-Hsien; Chen, Chih-Chieh; Kuo, Chung-Wen

    2017-01-01

    This study investigates the effects of five decontamination methods on the filter quality (qf) of three commercially available electret masks—N95, Gauze and Spunlace nonwoven masks. Newly developed evaluation methods, the overall filter quality (qf,o) and the qf ratio were applied to evaluate the effectiveness of decontamination methods for respirators. A scanning mobility particle sizer is utilized to measure the concentration of polydispersed particles with diameter 14.6–594 nm. The penetration of particles and pressure drop (Δp) through the mask are used to determine qf and qf,o. Experimental results reveal that the most penetrating particle size (MPS) for the pre-decontaminated N95, Gauze and Spunlace masks were 118 nm, 461 nm and 279 nm, respectively, and the respective penetration rates were 2.6%, 23.2% and 70.0%. The Δp through the pretreated N95 masks was 9.2 mm H2O at the breathing flow rate of heavy-duty workers, exceeding the Δp values obtained through Gauze and Spunlace masks. Decontamination increased the sizes of the most penetrating particles, changing the qf values of all of the masks: qf fell as particle size increased because the penetration increased. Bleach increased the Δp of N95, but destroyed the Gauze mask. However, the use of an autoclave reduces the Δp values of both the N95 and the Gauze mask. Neither the rice cooker nor ethanol altered the Δp of the Gauze mask. Chemical decontamination methods reduced the qf,o values for the three electret masks. The value of qf,o for PM0.1 exceeded that for PM0.1–0.6, because particles smaller than 100 nm had lower penetration, resulting in a better qf for a given pressure drop. The values of qf,o, particularly for PM0.1, reveal that for the tested treatments and masks, physical decontamination methods are less destructive to the filter than chemical methods. Nevertheless, when purchasing new or reusing FFRs, penetration should be regarded as the priority. PMID:29023492

  18. How do different brands of size 1 laryngeal mask airway compare with face mask ventilation in a dedicated laryngeal mask airway teaching manikin?

    PubMed

    Tracy, Mark Brian; Priyadarshi, Archana; Goel, Dimple; Lowe, Krista; Huvanandana, Jacqueline; Hinder, Murray

    2018-05-01

    International neonatal resuscitation guidelines recommend the use of laryngeal mask airway (LMA) with newborn infants (≥34 weeks' gestation or >2 kg weight) when bag-mask ventilation (BMV) or tracheal intubation is unsuccessful. Previous publications do not allow broad LMA device comparison. To compare delivered ventilation of seven brands of size 1 LMA devices with two brands of face mask using self-inflating bag (SIB). 40 experienced neonatal staff provided inflation cycles using SIB with positive end expiratory pressure (PEEP) (5 cmH 2 O) to a specialised newborn/infant training manikin randomised for each LMA and face mask. All subjects received prior education in LMA insertion and BMV. 12 415 recorded inflations for LMAs and face masks were analysed. Leak detected was lowest with i-gel brand, with a mean of 5.7% compared with face mask (triangular 42.7, round 35.7) and other LMAs (45.5-65.4) (p<0.001). Peak inspiratory pressure was higher with i-gel, with a mean of 28.9 cmH 2 O compared with face mask (triangular 22.8, round 25.8) and other LMAs (14.3-22.0) (p<0.001). PEEP was higher with i-gel, with a mean of 5.1 cmH 2 O compared with face mask (triangular 3.0, round 3.6) and other LMAs (0.6-2.6) (p<0.001). In contrast to other LMAs examined, i-gel had no insertion failures and all users found i-gel easy to use. This study has shown dramatic performance differences in delivered ventilation, mask leak and ease of use among seven different brands of LMA tested in a manikin model. This coupled with no partial or complete insertion failures and ease of use suggests i-gel LMA may have an expanded role with newborn resuscitation as a primary resuscitation device. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  19. Laser Doppler imaging of cutaneous blood flow through transparent face masks: a necessary preamble to computer-controlled rapid prototyping fabrication with submillimeter precision.

    PubMed

    Allely, Rebekah R; Van-Buendia, Lan B; Jeng, James C; White, Patricia; Wu, Jingshu; Niszczak, Jonathan; Jordan, Marion H

    2008-01-01

    A paradigm shift in management of postburn facial scarring is lurking "just beneath the waves" with the widespread availability of two recent technologies: precise three-dimensional scanning/digitizing of complex surfaces and computer-controlled rapid prototyping three-dimensional "printers". Laser Doppler imaging may be the sensible method to track the scar hyperemia that should form the basis of assessing progress and directing incremental changes in the digitized topographical face mask "prescription". The purpose of this study was to establish feasibility of detecting perfusion through transparent face masks using the Laser Doppler Imaging scanner. Laser Doppler images of perfusion were obtained at multiple facial regions on five uninjured staff members. Images were obtained without a mask, followed by images with a loose fitting mask with and without a silicone liner, and then with a tight fitting mask with and without a silicone liner. Right and left oblique images, in addition to the frontal images, were used to overcome unobtainable measurements at the extremes of face mask curvature. General linear model, mixed model, and t tests were used for data analysis. Three hundred seventy-five measurements were used for analysis, with a mean perfusion unit of 299 and pixel validity of 97%. The effect of face mask pressure with and without the silicone liner was readily quantified with significant changes in mean cutaneous blood flow (P < .5). High valid pixel rate laser Doppler imager flow data can be obtained through transparent face masks. Perfusion decreases with the application of pressure and with silicone. Every participant measured differently in perfusion units; however, consistent perfusion patterns in the face were observed.

  20. Masks for prevention of respiratory viruses on the BMT unit: results of a quality initiative.

    PubMed

    Sokol, Kelsey A; De la Vega-Diaz, Imelda; Edmondson-Martin, Kathleen; Kim, Sara; Tindle, Sharon; Wallach, Fran; Steinberg, Amir

    2016-12-01

    Respiratory viral infections (RVI) cause significant morbidity and mortality in hospitalized oncology patients. These viruses are easily spread from asymptomatic and/or symptomatic healthcare workers and visitors to immunocompromised patients, and literature review of facemasks for prevention of infection revealed mixed results. The Bone Marrow Transplant (BMT) Quality Assurance (QA) Committee at Mount Sinai began a surgical mask initiative on the BMT unit. The purpose of our initiative was to assess the impact of surgical mask implementation for healthcare workers and visitors on nosocomial RVI in all patients hospitalized on the BMT unit. We hypothesized that implementing surgical masks would reduce the number of hospital-acquired RVI. We performed a retrospective study involving all patients with malignancy hospitalized on the BMT unit for 4 years. During the latter 2 years, all healthcare workers and visitors were required to wear a surgical mask in every patient room on the BMT unit. Primary endpoint was incidence of RVI after implementation of surgical masks. The 2-year incidence of RVI in the pre-mask period was 14 out of a total of 15 001 patient days on the unit vs 2 out of 15 608 patient days after mask implementation. The difference in incidence of RVI within the two time intervals was noted to be statistically significant (P<.05, 2-proportion z-test). Our quality initiative demonstrated that surgical masks are an infection control modality that may provide benefit to oncology/BMT units by decreasing the risk for hospital-acquired RVI. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. First 65nm tape-out using inverse lithography technology (ILT)

    NASA Astrophysics Data System (ADS)

    Hung, Chi-Yuan; Zhang, Bin; Tang, Deming; Guo, Eric; Pang, Linyong; Liu, Yong; Moore, Andrew; Wang, Kechang

    2005-11-01

    This paper presents SMIC's first 65nm tape out results, in particularly, using ILT. ILT mathematically determines the mask features that produce the desired on-wafer results with best wafer pattern fidelity, largest process window or both. SMIC applied it to its first 65nm tape-out to study ILT performance and benefits for deep sub-wavelength lithography. SMIC selected 3 SRAM designs as the first test case, because SRAM bit-cells contain features which are challenging lithographically. Mask patterns generated from both conventional OPC and ILT were placed on the mask side-by-side. Mask manufacturability (including fracturing, writing time, inspection, and metrology) and wafer print performance of ILT were studied. The results demonstrated that ILT achieved better CD accuracy, produced substantially larger process window than conventional OPC, and met SMIC's 65nm process window requirements.

  2. Cross-orientation masking in human color vision: application of a two-stage model to assess dichoptic and monocular sources of suppression.

    PubMed

    Kim, Yeon Jin; Gheiratmand, Mina; Mullen, Kathy T

    2013-05-28

    Cross-orientation masking (XOM) occurs when the detection of a test grating is masked by a superimposed grating at an orthogonal orientation, and is thought to reveal the suppressive effects mediating contrast normalization. Medina and Mullen (2009) reported that XOM was greater for chromatic than achromatic stimuli at equivalent spatial and temporal frequencies. Here we address whether the greater suppression found in binocular color vision originates from a monocular or interocular site, or both. We measure monocular and dichoptic masking functions for red-green color contrast and achromatic contrast at three different spatial frequencies (0.375, 0.75, and 1.5 cpd, 2 Hz). We fit these functions with a modified two-stage masking model (Meese & Baker, 2009) to extract the monocular and interocular weights of suppression. We find that the weight of monocular suppression is significantly higher for color than achromatic contrast, whereas dichoptic suppression is similar for both. These effects are invariant across spatial frequency. We then apply the model to the binocular masking data using the measured values of the monocular and interocular sources of suppression and show that these are sufficient to account for color binocular masking. We conclude that the greater strength of chromatic XOM has a monocular origin that transfers through to the binocular site.

  3. Photomask etch system and process for 10nm technology node and beyond

    NASA Astrophysics Data System (ADS)

    Chandrachood, Madhavi; Grimbergen, Michael; Yu, Keven; Leung, Toi; Tran, Jeffrey; Chen, Jeff; Bivens, Darin; Yalamanchili, Rao; Wistrom, Richard; Faure, Tom; Bartlau, Peter; Crawford, Shaun; Sakamoto, Yoshifumi

    2015-10-01

    While the industry is making progress to offer EUV lithography schemes to attain ultimate critical dimensions down to 20 nm half pitch, an interim optical lithography solution to address an immediate need for resolution is offered by various integration schemes using advanced PSM (Phase Shift Mask) materials including thin e-beam resist and hard mask. Using the 193nm wavelength to produce 10nm or 7nm patterns requires a range of optimization techniques, including immersion and multiple patterning, which place a heavy demand on photomask technologies. Mask schemes with hard mask certainly help attain better selectivity and hence better resolution but pose integration challenges and defectivity issues. This paper presents a new photomask etch solution for attenuated phase shift masks that offers high selectivity (Cr:Resist > 1.5:1), tighter control on the CD uniformity with a 3sigma value approaching 1 nm and controllable CD bias (5-20 nm) with excellent CD linearity performance (<5 nm) down to the finer resolution. The new system has successfully demonstrated capability to meet the 10 nm node photomask CD requirements without the use of more complicated hard mask phase shift blanks. Significant improvement in post wet clean recovery performance was demonstrated by the use of advanced chamber materials. Examples of CD uniformity, linearity, and minimum feature size, and etch bias performance on 10 nm test site and production mask designs will be shown.

  4. Use of simulation to optimize the pinhole diameter and mask thickness for an x-ray backscatter imaging system

    NASA Astrophysics Data System (ADS)

    Vella, A.; Munoz, Andre; Healy, Matthew J. F.; Lane, David; Lockley, D.

    2017-08-01

    The PENELOPE Monte Carlo simulation code was used to determine the optimum thickness and aperture diameter of a pinhole mask for X-ray backscatter imaging in a security application. The mask material needs to be thick enough to absorb most X-rays, and the pinhole must be wide enough for sufficient field of view whilst narrow enough for sufficient image spatial resolution. The model consisted of a fixed geometry test object, various masks with and without pinholes, and a 1040 x 1340 pixels' area detector inside a lead lined camera housing. The photon energy distribution incident upon masks was flat up to selected energy limits. This artificial source was used to avoid the optimisation being specific to any particular X-ray source technology. The pixelated detector was modelled by digitising the surface area represented by the PENELOPE phase space file and integrating the energies of the photons impacting within each pixel; a MATLAB code was written for this. The image contrast, signal to background ratio, spatial resolution, and collimation effect were calculated at the simulated detector as a function of pinhole diameter and various thicknesses of mask made of tungsten, tungsten/epoxy composite or bismuth alloy. A process of elimination was applied to identify suitable masks for a viable X-ray backscattering security application.

  5. Easy facial analysis using the facial golden mask.

    PubMed

    Kim, Yong-Ha

    2007-05-01

    For over 2000 years, many artists and scientists have tried to understand or quantify the form of the perfect, ideal, or most beautiful face both in art and in vivo (life). A mathematical relationship has been consistently and repeatedly reported to be present in beautiful things. This particular relationship is the golden ratio. It is a mathematical ratio of 1.618:1 that seems to appear recurrently in beautiful things in nature as well as in other things that are seen as beautiful. Dr. Marquardt made the facial golden mask that contains and includes all of the one-dimensional and two-dimensional geometric golden elements formed from the golden ratio. The purpose of this study is to evaluate the usefulness of the golden facial mask. In 40 cases, the authors applied the facial golden mask to preoperative and postoperative photographs and scored each photograph on a 1 to 5 scale from the perspective of their personal aesthetic views. The score was lower when the facial deformity was severe, whereas it was higher when the face was attractive. Compared with the average scores of facial mask applied photographs and nonapplied photographs using a nonparametric test, statistical significance was not reached (P > 0.05). This implies that the facial golden mask may be used as an analytical tool. The facial golden mask is easy to apply, inexpensive, and relatively objective. Therefore, the authors introduce it as a useful facial analysis.

  6. Multivariate analyses of tinnitus complaint and change in tinnitus complaint: a masker study.

    PubMed

    Jakes, S; Stephens, S D

    1987-11-01

    Multivariate statistical techniques were used to re-analyse the data from the recent DHSS multi-centre masker study. These analyses were undertaken to three ends. First, to clarify and attempt to replicate the previously found factor structure of complaints about tinnitus. Secondly, to attempt to identify common factors in the change or improvement measures pre- and post-masker treatment. Thirdly, to identify predictors of any such outcome factors. Two complaint factors were identified; 'Distress' and 'intrusiveness'. A series of analyses were conducted on change measures using different numbers of subjects and variables. When only semantic differential scales were used, the change factors were very similar to the complaint factors noted above. When variables measuring other aspects of improvement were included, several other factors were identified. These included; 'tinnitus helped', 'masking effects', 'residual inhibition' and 'matched loudness'. Twenty-five conceptually distinct predictors of outcome were identified. These predictor variables were quite different for different outcome factors. For example, high-frequency hearing loss was a predictor of tinnitus being helped by the masker, and a low frequency match and a low masking threshold predicted therapeutic success on residual inhibition. Decrease in matched loudness was predicted by louder tinnitus initially.

  7. The effect of massage on heart rate variability in preterm infants

    PubMed Central

    Smith, SL.; Lux, R.; Haley, S.; Slater, H.; Beechy, J.; Moyer-Mileur, LJ.

    2012-01-01

    Objective To test the hypothesis that massage would improve autonomic nervous system (ANS) function as measured by heart rate variability (HRV) in preterm infants. Study Design Medically stable, 29- to 32-week preterm infants (17 massage, 20 control) were enrolled in a masked, randomized longitudinal study. Licensed massage therapists provided the massage or control condition twice a day for 4 weeks. Weekly HRV, a measure of ANS development and function, was analyzed using SPSS generalized estimating equations. Results Infant characteristics were similar between groups. HRV improved in massaged infants but not in the control infants (P<0.05). Massaged males had a greater improvement in HRV than females (P<0.05). HRV in massaged infants was on a trajectory comparable to term-born infants by study completion. Conclusion Massage-improved HRV in a homogeneous sample of hospitalized, medically stable, preterm male infants and may improve infant response to exogenous stressors. We speculate that massage improves ANS function in these infants. PMID:22538325

  8. Developmental Effects in the Masking-Level Difference

    ERIC Educational Resources Information Center

    Hall, Joseph W.; Buss, Emily; Grose, John H.; Dev, Madhu B.

    2004-01-01

    Adults and children (aged 5 years 1 month to 10 years 8 months) were tested in a masking-level difference (MLD) paradigm in which detection of brief signals was contrasted for signal placement in masker envelope maxima versus masker envelope minima. Maskers were 50-Hz-wide noise bands centered on 500 Hz, and the signals were So or S[pi] 30-ms,…

  9. Repetition and Masked Form Priming within and between Languages Using Word and Nonword Neighbors

    ERIC Educational Resources Information Center

    Dijkstra, Ton; Hilberink-Schulpen, Beryl; van Heuven, Walter J. B.

    2010-01-01

    If access to the bilingual lexicon takes place in a language independent way, monolingual repetition and masked form priming accounts should be directly applicable to bilinguals. We tested such an account (Grainger and Jacobs, 1999) and extended it to explain bilingual effects from L2 to L1. Dutch-English bilinguals made a lexical decision on a…

  10. Perceptual and Cognitive Factors Imposing “Speed Limits” on Reading Rate: A Study with the Rapid Serial Visual Presentation

    PubMed Central

    Spinelli, Donatella; Zoccolotti, Pierluigi; De Luca, Maria; Martelli, Marialuisa

    2016-01-01

    Adults read at high speed, but estimates of their reading rate vary greatly, i.e., from 100 to 1500 words per minute (wpm). This discrepancy is likely due to different recording methods and to the different perceptual and cognitive processes involved in specific test conditions. The present study investigated the origins of these notable differences in RSVP reading rate (RR). In six experiments we investigated the role of many different perceptual and cognitive variables. The presence of a mask caused a steep decline in reading rate, with an estimated masking cost of about 200 wpm. When the decoding process was isolated, RR approached values of 1200 wpm. When the number of stimuli exceeded the short-term memory span, RR decreased to 800 wpm. The semantic context contributed to reading speed only by a factor of 1.4. Finally, eye movements imposed an upper limit on RR (around 300 wpm). Overall, data indicate a speed limit of 300 wpm, which corresponds to the time needed for eye movement execution, i.e., the most time consuming mechanism. Results reconcile differences in reading rates reported by different laboratories and thus provide suggestions for targeting different components of reading rate. PMID:27088226

  11. Selective processing of smoking-related cues in smokers: manipulation of deprivation level and comparison of three measures of processing bias.

    PubMed

    Mogg, Karin; Bradley, Brendan P

    2002-12-01

    Recent theories of addiction suggest that an attentional bias for drug-related cues plays an important role in maintaining drug-taking behaviours. A key feature of the present study is that it used three different measures of processing bias for linguistic and pictorial smoking-related cues: masked and unmasked conditions of the modified Stroop task, and a pictorial version of the visual probe task. Participants were smokers (n = 27), who were tested twice, with deprivation level manipulated as a within-subjects variable. They were asked to abstain from smoking for 12 h before one session, and to smoke normally before the other. Results were consistent with an attentional bias for smoking-related pictures on the visual probe task, and for smoking-related words in the unmasked condition of the modified Stroop task. The latter bias was most strongly predicted by self-reported urge to smoke, rather than by the deprivation manipulation. There was no evidence of a preconscious bias for smoking cues. The three measures of cognitive bias (from masked and unmasked Stroop and visual probe tasks) were not significantly correlated with each other, which suggests they may tap different underlying mechanisms. We discuss the results with respect to conceptualizations of selective attention, addiction and motivational states in general.

  12. Is tinnitus an early voice of masked hypertension? High masked hypertension rate in patients with tinnitus.

    PubMed

    Gun, Taylan; Özkan, Selçuk; Yavuz, Bunyamin

    2018-04-23

    Tinnitus is hearing a sound without any external acoustic stimulus. There are some clues of hypertension can cause tinnitus in different ways. The aim of the study was to evaluate the relationship between tinnitus and masked hypertension including echocardiographic parameters and severity of tinnitus. This study included 88 patients with tinnitus of at least 3 months duration and 85 age and gender-matched control subjects. Tinnitus severity index was used to classify the patients with tinnitus. After a complete medical history, all subjects underwent routine laboratory examination, office blood pressure measurement, hearing tests and ambulatory blood pressure monitoring. Masked hypertension is defined as normal office blood pressure measurement and high ambulatory blood pressure level. Baseline characteristics in patients and controls were similar. Prevalence of masked hypertension was significantly higher in patients with tinnitus than controls (18.2% vs 3.5%, p = 0.002). Office diastolic BP (76 ± 8.1 vs. 72.74 ± 8.68, p = 0.01), ambulatory 24-H diastolic BP (70.2 ± 9.6 vs. 66.9 ± 6.1, p = 0.07) and ambulatory daytime diastolic BP (73.7 ± 9.5 vs. 71.1 ± 6.2, p = 0.03) was significantly higher in patients with tinnitus than control group. Tinnitus severity index in patients without masked hypertension was 0 and tinnitus severity index in patients with masked hypertension were 2 (1-5). This study demonstrated that masked hypertension must be kept in mind if there is a complaint of tinnitus without any other obvious reason.

  13. Low surface energy polymeric release coating for improved contact print lithography

    NASA Astrophysics Data System (ADS)

    Mancini, David P.; Resnick, Douglas J.; Gehoski, Kathleen A.; Popovich, Laura L.; Chang, Daniel

    2002-03-01

    Contact printing has been used for decades in many various lithography applications in the microelectronic industry. While vacuum contact printing processes offer sub-micron resolution and high throughput, they often suffer from some important drawbacks. One of the most common problems is degradation in both resolution and defect density which occurs when the same mask si used for multiple exposures without frequent mask cleans. This is largely due to the relatively high surface energy of both quartz and chrome and the tendency of most photoresists to adhere to these surfaces. As a result, when a mask and wafer are pressed into intimate contact, resist will tend to stick to the mask creating a defect on the wafer, effectively propagating defects to subsequent wafers. In this study, DuPont Teflon AF 1601S is used as a photomask coating and evaluated for its ability to act as a release agent and reduce defects while maintaining resolution for multiple exposures. Teflon AF is an amorphous, transparent, low surface energy, polymeric material that can be spin coated into a thin conformal film. Tests have shown that when using an uncoated mask in vacuum contact, resolution of 0.75 micrometers dense lines is severely degraded after less than 10 consecutive exposures. However, when the mask is coated, 0.75 micrometers dense lines were successfully resolved using vacuum contact for over 200 exposures without cleaning. In addition, it has been demonstrated that Teflon AF coatings impart to a mask a self-cleaning capability, since particles tend to stick to the photoresist rather than the mask. A coated mask, which was purposefully contaminated with particulates, resolved 0.75 micrometers dense lines on all but the first wafer of a series of 25 consecutive exposures. The patented mask releases layer process has successfully been demonstrated with a positive novolak resist. Additional data which describes the system chemistry, dilution and coating process, and film morphology are also presented.

  14. The use of masks and respirators to prevent transmission of influenza: a systematic review of the scientific evidence

    PubMed Central

    bin‐Reza, Faisal; Lopez Chavarrias, Vicente; Nicoll, Angus; Chamberland, Mary E.

    2011-01-01

    Please cite this paper as: bin‐Reza et al. (2012) The use of masks and respirators to prevent transmission of influenza: a systematic review of the scientific evidence. Influenza and Other Respiratory Viruses 6(4), 257–267. There are limited data on the use of masks and respirators to reduce transmission of influenza. A systematic review was undertaken to help inform pandemic influenza guidance in the United Kingdom. The initial review was performed in November 2009 and updated in June 2010 and January 2011. Inclusion criteria included randomised controlled trials and quasi‐experimental and observational studies of humans published in English with an outcome of laboratory‐confirmed or clinically‐diagnosed influenza and other viral respiratory infections. There were 17 eligible studies. Six of eight randomised controlled trials found no significant differences between control and intervention groups (masks with or without hand hygiene; N95/P2 respirators). One household trial found that mask wearing coupled with hand sanitiser use reduced secondary transmission of upper respiratory infection/influenza‐like illness/laboratory‐confirmed influenza compared with education; hand sanitiser alone resulted in no reduction. One hospital‐based trial found a lower rate of clinical respiratory illness associated with non‐fit‐tested N95 respirator use compared with medical masks. Eight of nine retrospective observational studies found that mask and/or respirator use was independently associated with a reduced risk of severe acute respiratory syndrome (SARS). Findings, however, may not be applicable to influenza and many studies were suboptimal. None of the studies established a conclusive relationship between mask/respirator use and protection against influenza infection. Some evidence suggests that mask use is best undertaken as part of a package of personal protection especially hand hygiene. The effectiveness of masks and respirators is likely linked to early, consistent and correct usage. PMID:22188875

  15. Mask_explorer: A tool for exploring brain masks in fMRI group analysis.

    PubMed

    Gajdoš, Martin; Mikl, Michal; Mareček, Radek

    2016-10-01

    Functional magnetic resonance imaging (fMRI) studies of the human brain are appearing in increasing numbers, providing interesting information about this complex system. Unique information about healthy and diseased brains is inferred using many types of experiments and analyses. In order to obtain reliable information, it is necessary to conduct consistent experiments with large samples of subjects and to involve statistical methods to confirm or reject any tested hypotheses. Group analysis is performed for all voxels within a group mask, i.e. a common space where all of the involved subjects contribute information. To our knowledge, a user-friendly interface with the ability to visualize subject-specific details in a common analysis space did not yet exist. The purpose of our work is to develop and present such interface. Several pitfalls have to be avoided while preparing fMRI data for group analysis. One such pitfall is spurious non-detection, caused by inferring conclusions in the volume of a group mask that has been corrupted due to a preprocessing failure. We describe a MATLAB toolbox, called the mask_explorer, designed for prevention of this pitfall. The mask_explorer uses a graphical user interface, enables a user-friendly exploration of subject masks and is freely available. It is able to compute subject masks from raw data and create lists of subjects with potentially problematic data. It runs under MATLAB with the widely used SPM toolbox. Moreover, we present several practical examples where the mask_explorer is usefully applied. The mask_explorer is designed to quickly control the quality of the group fMRI analysis volume and to identify specific failures related to preprocessing steps and acquisition. It helps researchers detect subjects with potentially problematic data and consequently enables inspection of the data. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  16. Large-area soft x-ray projection lithography using multilayer mirrors structured by RIE

    NASA Astrophysics Data System (ADS)

    Rahn, Steffen; Kloidt, Andreas; Kleineberg, Ulf; Schmiedeskamp, Bernt; Kadel, Klaus; Schomburg, Werner K.; Hormes, F. J.; Heinzmann, Ulrich

    1993-01-01

    SXPL (soft X-ray projection lithography) is one of the most promising applications of X-ray reflecting optics using multilayer mirrors. Within our collaboration, such multilayer mirrors were fabricated, characterized, laterally structured and then used as reflection masks in a projecting lithography procedure. Mo/Si-multilayer mirrors were produced by electron beam evaporation in UHV under thermal treatment with an in-situ X-ray controlled thickness in the region of 2d equals 14 nm. The reflectivities measured at normal incidence reached up to 54%. Various surface analysis techniques have been applied in order to characterize and optimize the X-ray mirrors. The multilayers were patterned by reactive ion etching (RIE) with CF(subscript 4), using a photoresist as the etch mask, thus producing X-ray reflection masks. The masks were tested in the synchrotron radiation laboratory of the electron accelerator ELSA at the Physikalisches Institut of Bonn University. A double crystal X-ray monochromator was modified so as to allow about 0.5 cm(superscript 2) of the reflection mask to be illuminated by white synchrotron radiation. The reflected patterns were projected (with an energy of 100 eV) onto the resist (Hoechst AZ PF 514), which was mounted at an average distance of about 7 mm. In the first test-experiments, structure sizes down to 8 micrometers were nicely reproduced over the whole of the exposed area. Smaller structures were distorted by Fresnel-diffraction. The theoretically calculated diffraction images agree very well with the observed images.

  17. Does visual letter similarity modulate masked form priming in young readers of Arabic?

    PubMed

    Perea, Manuel; Abu Mallouh, Reem; Mohammed, Ahmed; Khalifa, Batoul; Carreiras, Manuel

    2018-05-01

    We carried out a masked priming lexical decision experiment to study whether visual letter similarity plays a role during the initial phases of word processing in young readers of Arabic (fifth graders). Arabic is ideally suited to test these effects because most Arabic letters share their basic shape with at least one other letter and differ only in the number/position of diacritical points (e.g., ض - ص ;ظ - ط ;غ - ع ;ث - ت - ن ب ;ذ - د ;خ - ح - ج ;ق - ف ;ش - س ;ز - ر). We created two one-letter-different priming conditions for each target word, in which a letter from the consonantal root was substituted by another letter that did or did not keep the same shape (e.g., خدمة - حدمة vs. خدمة - فدمة). Another goal of the current experiment was to test the presence of masked orthographic priming effects, which are thought to be unreliable in Semitic languages. To that end, we included an unrelated priming condition. We found a sizable masked orthographic priming effect relative to the unrelated condition regardless of visual letter similarity, thereby revealing that young readers are able to quickly process the diacritical points of Arabic letters. Furthermore, the presence of masked orthographic priming effects in Arabic suggests that the word identification stream in Indo-European and Semitic languages is more similar than previously thought. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Radiated Emissions Test Approach

    DOT National Transportation Integrated Search

    2015-10-02

    1. Draft Department of Transportation (DOT) Test Plan to Develop : Interference Tolerance Masks for GNSS Receivers in the L1 : Radiofrequency Band (1559 1610 MHz) provides high level : overview of radiated emissions test setup : 2. Presenta...

  19. The combined exercise stress echocardiography and cardiopulmonary exercise test for identification of masked heart failure with preserved ejection fraction in patients with hypertension.

    PubMed

    Nedeljkovic, Ivana; Banovic, Marko; Stepanovic, Jelena; Giga, Vojislav; Djordjevic-Dikic, Ana; Trifunovic, Danijela; Nedeljkovic, Milan; Petrovic, Milan; Dobric, Milan; Dikic, Nenad; Zlatar, Milan; Beleslin, Branko

    2016-01-01

    Heart failure with preserved ejection fraction (HFpEF) is commonly associated with hypertension (HTN). However, resting echocardiography (ECHO) can underestimate the severity of disease. Exercise stress echocardiography (ESE) and the cardiopulmonary exercise testing (CPX) appeared to be useful tests in dynamic assessment of HFpEF. The value of combined exercise stress echocardiography cardiopulmonary testing (ESE-CPX) in the identification of masked HFpEF is still undetermined. The purpose of this study was to analyse the value of the combined ESE-CPX in the identification of masked HFpEF in patients with HTN, dyspnoea and normal resting left ventricular (LV) systolic and diastolic function. We studied 87 patients with HTN, exertional dyspnoea and normal resting LV function. They all underwent ESE-CPX testing (supine bicycle, ramp protocol, 15 W/min). ECHO measurements were performed at rest, and at peak load. Achievement of peak E/e' ratio>15 was a marker for masked HFpEF. Increase of E/e'>15 occurred in 8/87 patients (9.2%) during ESE-CPX. Those patients had the lower peak VO2 (p = 0.012), the lower VO2 at anaerobic threshold (p = 0.025), the lower workload (p = 0.026), the lower peak partial pressure end tidal carbon dioxide (PetCO2) (p < 0.0001), and the higher VE/VCO2 slope (p < 0.0001) which was an independent multivariate predictor of HFpEF (p = 0.021), with the cut-off value of 32.95 according to the receiver-operator characteristic (ROC) curve (sensitivity (Sn) 100%, specificity (Sp) 90%). The combined ESE-CPX test is feasible and reliable test that can unmask HFpEF and may become an important aid in the early diagnosis of HFpEF, excluding the other causes of exertional dyspnoea. © The European Society of Cardiology 2015.

  20. Conventional Energy and Macronutrient Variables Distort the Accuracy of Children’s Dietary Reports: Illustrative Data from a Validation Study of Effect of Order Prompts

    PubMed Central

    Baxter, Suzanne Domel; Smith, Albert F.; Hardin, James W.; Nichols, Michele D.

    2008-01-01

    Objective Validation-study data are used to illustrate that conventional energy and macronutrient (protein, carbohydrate, fat) variables, which disregard accuracy of reported items and amounts, misrepresent reporting accuracy. Reporting-error-sensitive variables are proposed which classify reported items as matches or intrusions, and reported amounts as corresponding or overreported. Methods 58 girls and 63 boys were each observed eating school meals on 2 days separated by ≥4 weeks, and interviewed the morning after each observation day. One interview per child had forward-order (morning-to-evening) prompts; one had reverse-order prompts. Original food-item-level analyses found a sex-x-order prompt interaction for omission rates. Current analyses compared reference (observed) and reported information transformed to energy and macronutrients. Results Using conventional variables, reported amounts were less than reference amounts (ps<0.001; paired t-tests); report rates were higher for the first than second interview for energy, protein, and carbohydrate (ps≤0.049; mixed models). Using reporting-error-sensitive variables, correspondence rates were higher for girls with forward- but boys with reverse-order prompts (ps≤0.041; mixed models); inflation ratios were lower with reverse- than forward-order prompts for energy, carbohydrate, and fat (ps≤0.045; mixed models). Conclusions Conventional variables overestimated reporting accuracy and masked order prompt and sex effects. Reporting-error-sensitive variables are recommended when assessing accuracy for energy and macronutrients in validation studies. PMID:16959308

  1. The effectiveness of respiratory protection worn by communities to protect from volcanic ash inhalation. Part I: Filtration efficiency tests.

    PubMed

    Mueller, William; Horwell, Claire J; Apsley, Andrew; Steinle, Susanne; McPherson, Stephanie; Cherrie, John W; Galea, Karen S

    2018-04-22

    During volcanic eruptions and their aftermath, communities may be concerned about the impacts of inhaling volcanic ash. Access to effective respiratory protection (RP) is therefore important for many people in volcanic areas all over the world. However, evidence to support the use of effective RP during such crises is currently lacking. The aim of this study was to build the first evidence base on the effectiveness of common materials used to protect communities from ash inhalation in volcanic crises. We obtained 17 forms of RP, covering various types of cloth through to disposable masks (typically used in occupational settings), which communities are known to wear during volcanic crises. The RP materials were characterised and subjected to filtration efficiency (FE) tests, which were performed with three challenge dusts: ashes from Sakurajima (Japan) and Soufrière Hills (Montserrat) volcanoes and aluminium oxide (Aloxite), chosen as a low-toxicity surrogate dust of similar particle size distribution. FE tests were conducted at two concentrations (1.5 mg/m 3 and 2.5 mg/m 3 ) and two flow rates (equivalent to 40 and 80 l/min through 15.9 cm 2 sections of each RP type). Each material was held in a sample holder and PM 2.5 dust concentrations were measured both outside the mask material and inside the sample holder to determine FE. A limited number of tests were undertaken to assess the effect on FE of wetting a bandana and a surgical mask, as well as folding a bandana to provide multiple filter layers. Overall, four RP materials performed very well against volcanic ash, with median FEs in excess of 98% (N95-equiv., N99-equiv., PM 2.5 surgical (Japan), and Basic flat-fold (Indonesia)). The two standard surgical masks tested had median FEs of 89-91%. All other materials had median FEs ranging from 23 to 76% with no cloth materials achieving >44%. Folding a bandana resulted in better FE (40%; 3× folded) than single-layered material (29%). Wetting the bandana and surgical mask material did not improve FE overall. This first evidence base on the FE of common materials used to protect communities in volcanic crises from ash inhalation has been extended in a companion study (Steinle et al., 2018) on the total inward leakage of the best-performing masks when worn by human volunteers. This will provide a complete assessment of the effectiveness of these RP types. Copyright © 2018 The Authors. Published by Elsevier GmbH.. All rights reserved.

  2. Examining the policies and guidelines around the use of masks and respirators by healthcare workers in China, Pakistan and Vietnam

    PubMed Central

    MacIntyre, C Raina; Zheng, Yang; Wang, Quanyi; Toor, Zafar Iqbal; Dung, Tham Chi; Hien, Nguyen Tran; Seale, Holly

    2014-01-01

    Background: There is an ongoing debate regarding the type of respiratory protection that should be recommended for use for healthcare workers. Materials and methods: A cross-sectional survey was conducted in three countries: China, Pakistan and Vietnam. Results: In China and Pakistan, the infection control guidelines were developed to be in line with the recommendations from the World Health Organization (WHO) and the Centers for Disease Control and Prevention, while in the Vietnamese guidelines the recommendations correspond with the WHO suggestions only. The guidelines from all three countries document the need for training and fit testing; however there is no system to monitor the training and fit testing programs. Across the three countries, there was some inconsistency with regard to the types of products (i.e. masks vs. respirators) recommended for influenza, severe acute respiratory syndrome (SARS) and tuberculosis. Conclusions: Available evidence should be examined and a comprehensive policy should be developed on the use of masks and respirators. The policy should address critical areas such as regulation, training, fit testing and reuse. PMID:28989404

  3. Examining the policies and guidelines around the use of masks and respirators by healthcare workers in China, Pakistan and Vietnam.

    PubMed

    Chughtai, Abrar Ahmad; MacIntyre, C Raina; Zheng, Yang; Wang, Quanyi; Toor, Zafar Iqbal; Dung, Tham Chi; Hien, Nguyen Tran; Seale, Holly

    2015-03-01

    There is an ongoing debate regarding the type of respiratory protection that should be recommended for use for healthcare workers. A cross-sectional survey was conducted in three countries: China, Pakistan and Vietnam. In China and Pakistan, the infection control guidelines were developed to be in line with the recommendations from the World Health Organization (WHO) and the Centers for Disease Control and Prevention, while in the Vietnamese guidelines the recommendations correspond with the WHO suggestions only. The guidelines from all three countries document the need for training and fit testing; however there is no system to monitor the training and fit testing programs. Across the three countries, there was some inconsistency with regard to the types of products (i.e. masks vs. respirators) recommended for influenza, severe acute respiratory syndrome (SARS) and tuberculosis. Available evidence should be examined and a comprehensive policy should be developed on the use of masks and respirators. The policy should address critical areas such as regulation, training, fit testing and reuse.

  4. Respiratory fit testing for farmworkers in the Black Dirt region of Hudson Valley, New York.

    PubMed

    Earle-Richardson, Giulia; Fiske, Todd; Wyckoff, Sherry; Shuford, James; May, John

    2014-01-01

    Respiratory protection in agriculture has lagged behind other industries. Migrant farmworkers often work in dusty environments yet do not receive appropriate, fitted respiratory protection. During May and June of 2013, researchers pilot-tested a respiratory protection program adapted to fit the unique needs of migrant and seasonal farmworkers. It was implemented in Spanish, with literacy support, at convenient times and locations. Additionally, staff was known to workers, and a farmworker medical center provided medical follow-up. Fifty-six farmworkers participated (68%; 82 invited). Of the participants, 88% were male; 20% reported using respiratory protection. One worker had been fit tested previously; 57% reported being exposed to pesticides. All but six farmworkers passed the medical clearance (91%). The mask most commonly fit to the American-born population was a good fit for only 41% of Latino farmworkers. The fact that two thirds of invited farmworkers participated in the clearance and over half completed mask fitting indicates that the modified protocol meets farmworker needs. A wide range of mask types should be made available for Latino farmworkers.

  5. Speech-on-speech masking with variable access to the linguistic content of the masker speech for native and nonnative english speakers.

    PubMed

    Calandruccio, Lauren; Bradlow, Ann R; Dhar, Sumitrajit

    2014-04-01

    Masking release for an English sentence-recognition task in the presence of foreign-accented English speech compared with native-accented English speech was reported in Calandruccio et al (2010a). The masking release appeared to increase as the masker intelligibility decreased. However, it could not be ruled out that spectral differences between the speech maskers were influencing the significant differences observed. The purpose of the current experiment was to minimize spectral differences between speech maskers to determine how various amounts of linguistic information within competing speech Affiliationect masking release. A mixed-model design with within-subject (four two-talker speech maskers) and between-subject (listener group) factors was conducted. Speech maskers included native-accented English speech and high-intelligibility, moderate-intelligibility, and low-intelligibility Mandarin-accented English. Normalizing the long-term average speech spectra of the maskers to each other minimized spectral differences between the masker conditions. Three listener groups were tested, including monolingual English speakers with normal hearing, nonnative English speakers with normal hearing, and monolingual English speakers with hearing loss. The nonnative English speakers were from various native language backgrounds, not including Mandarin (or any other Chinese dialect). Listeners with hearing loss had symmetric mild sloping to moderate sensorineural hearing loss. Listeners were asked to repeat back sentences that were presented in the presence of four different two-talker speech maskers. Responses were scored based on the key words within the sentences (100 key words per masker condition). A mixed-model regression analysis was used to analyze the difference in performance scores between the masker conditions and listener groups. Monolingual English speakers with normal hearing benefited when the competing speech signal was foreign accented compared with native accented, allowing for improved speech recognition. Various levels of intelligibility across the foreign-accented speech maskers did not influence results. Neither the nonnative English-speaking listeners with normal hearing nor the monolingual English speakers with hearing loss benefited from masking release when the masker was changed from native-accented to foreign-accented English. Slight modifications between the target and the masker speech allowed monolingual English speakers with normal hearing to improve their recognition of native-accented English, even when the competing speech was highly intelligible. Further research is needed to determine which modifications within the competing speech signal caused the Mandarin-accented English to be less effective with respect to masking. Determining the influences within the competing speech that make it less effective as a masker or determining why monolingual normal-hearing listeners can take advantage of these differences could help improve speech recognition for those with hearing loss in the future. American Academy of Audiology.

  6. Across-site patterns of modulation detection: Relation to speech recognitiona)

    PubMed Central

    Garadat, Soha N.; Zwolan, Teresa A.; Pfingst, Bryan E.

    2012-01-01

    The aim of this study was to identify across-site patterns of modulation detection thresholds (MDTs) in subjects with cochlear implants and to determine if removal of sites with the poorest MDTs from speech processor programs would result in improved speech recognition. Five hundred millisecond trains of symmetric-biphasic pulses were modulated sinusoidally at 10 Hz and presented at a rate of 900 pps using monopolar stimulation. Subjects were asked to discriminate a modulated pulse train from an unmodulated pulse train for all electrodes in quiet and in the presence of an interleaved unmodulated masker presented on the adjacent site. Across-site patterns of masked MDTs were then used to construct two 10-channel MAPs such that one MAP consisted of sites with the best masked MDTs and the other MAP consisted of sites with the worst masked MDTs. Subjects’ speech recognition skills were compared when they used these two different MAPs. Results showed that MDTs were variable across sites and were elevated in the presence of a masker by various amounts across sites. Better speech recognition was observed when the processor MAP consisted of sites with best masked MDTs, suggesting that temporal modulation sensitivity has important contributions to speech recognition with a cochlear implant. PMID:22559376

  7. Discriminability measures for predicting readability of text on textured backgrounds

    NASA Technical Reports Server (NTRS)

    Scharff, L. F.; Hill, A. L.; Ahumada, A. J. Jr; Watson, A. B. (Principal Investigator)

    2000-01-01

    Several discriminability measures were examined for their ability to predict reading search times for three levels of text contrast and a range of backgrounds (plain, a periodic texture, and four spatial-frequency-filtered textures created from the periodic texture). Search times indicate that these background variations only affect readability when the text contrast is low, and that spatial frequency content of the background affects readability. These results were not well predicted by the single variables of text contrast (Spearman rank correlation = -0.64) and background RMS contrast (0.08), but a global masking index and a spatial-frequency-selective masking index led to better predictions (-0.84 and -0.81, respectively). c2000 Optical Society of America.

  8. Evaluation of Decision Trees for Cloud Detection from AVHRR Data

    NASA Technical Reports Server (NTRS)

    Shiffman, Smadar; Nemani, Ramakrishna

    2005-01-01

    Automated cloud detection and tracking is an important step in assessing changes in radiation budgets associated with global climate change via remote sensing. Data products based on satellite imagery are available to the scientific community for studying trends in the Earth's atmosphere. The data products include pixel-based cloud masks that assign cloud-cover classifications to pixels. Many cloud-mask algorithms have the form of decision trees. The decision trees employ sequential tests that scientists designed based on empirical astrophysics studies and simulations. Limitations of existing cloud masks restrict our ability to accurately track changes in cloud patterns over time. In a previous study we compared automatically learned decision trees to cloud masks included in Advanced Very High Resolution Radiometer (AVHRR) data products from the year 2000. In this paper we report the replication of the study for five-year data, and for a gold standard based on surface observations performed by scientists at weather stations in the British Islands. For our sample data, the accuracy of automatically learned decision trees was greater than the accuracy of the cloud masks p < 0.001.

  9. Analytical treatment of the deformation behavior of EUVL masks during electrostatic chucking

    NASA Astrophysics Data System (ADS)

    Brandstetter, Gerd; Govindjee, Sanjay

    2012-03-01

    A new analytical approach is presented to predict mask deformation during electro-static chucking in next generation extreme-ultraviolet-lithography (EUVL). Given an arbitrary profile measurement of the mask and chuck non-flatness, this method has been developed as an alternative to time-consuming finite element simulations for overlay error correction algorithms. We consider the feature transfer of each harmonic component in the profile shapes via linear elasticity theory and demonstrate analytically how high spatial frequencies are filtered. The method is compared to presumably more accurate finite element simulations and has been tested successfully in an overlay error compensation experiment, where the residual error y-component could be reduced by a factor 2. As a side outcome, the formulation provides a tool to estimate the critical pin-size and -pitch such that the distortion on the mask front-side remains within given tolerances. We find for a numerical example that pin-pitches of less than 5 mm will result in a mask pattern-distortion of less than 1 nm if the chucking pressure is below 30 kPa.

  10. Analytical treatment of the deformation behavior of extreme-ultraviolet-lithography masks during electrostatic chucking

    NASA Astrophysics Data System (ADS)

    Brandstetter, Gerd; Govindjee, Sanjay

    2012-10-01

    A new analytical approach is presented to predict mask deformation during electrostatic chucking in next-generation extreme-ultraviolet-lithography. Given an arbitrary profile measurement of the mask and chuck nonflatness, this method has been developed as an alternative to time-consuming finite element simulations for overlay error correction algorithms. We consider the feature transfer of each harmonic component in the profile shapes via linear elasticity theory and demonstrate analytically how high spatial frequencies are filtered. The method is compared to presumably more accurate finite element simulations and has been tested successfully in an overlay error compensation experiment, where the residual error y-component could be reduced by a factor of 2. As a side outcome, the formulation provides a tool to estimate the critical pin-size and -pitch such that the distortion on the mask front-side remains within given tolerances. We find for a numerical example that pin-pitches of less than 5 mm will result in a mask pattern distortion of less than 1 nm if the chucking pressure is below 30 kPa.

  11. Diffractive phase-shift lithography photomask operating in proximity printing mode.

    PubMed

    Cirino, Giuseppe A; Mansano, Ronaldo D; Verdonck, Patrick; Cescato, Lucila; Neto, Luiz G

    2010-08-02

    A phase shift proximity printing lithographic mask is designed, manufactured and tested. Its design is based on a Fresnel computer-generated hologram, employing the scalar diffraction theory. The obtained amplitude and phase distributions were mapped into discrete levels. In addition, a coding scheme using sub-cells structure was employed in order to increase the number of discrete levels, thus increasing the degree of freedom in the resulting mask. The mask is fabricated on a fused silica substrate and an amorphous hydrogenated carbon (a:C-H) thin film which act as amplitude modulation agent. The lithographic image is projected onto a resist coated silicon wafer, placed at a distance of 50 microm behind the mask. The results show a improvement of the achieved resolution--linewidth as good as 1.5 microm--what is impossible to obtain with traditional binary masks in proximity printing mode. Such achieved dimensions can be used in the fabrication of MEMS and MOEMS devices. These results are obtained with a UV laser but also with a small arc lamp light source exploring the partial coherence of this source.

  12. Formulation design of taste-masked particles, including famotidine, for an oral fast-disintegrating dosage form.

    PubMed

    Mizumoto, Takao; Tamura, Tetsuya; Kawai, Hitoshi; Kajiyama, Atsushi; Itai, Shigeru

    2008-04-01

    In this study, the taste-masking of famotidine, which could apply to any fast-disintegrating tablet, was investigated using the spray-dry method. The target characteristics of taste-masked particles were set as follows: the dissolution rate is not to be more than 30% at 1 min and not less than 85% at 15 min, and the particle size is not to be more than 150 microm in diameter to avoid a gritty feeling in the mouth. The target dissolution profiles of spray-dried particles consisting of Aquacoat ECD30 and Eudragit NE30D or triacetin was accomplished by the screening of formulas and the appropriate lab-scale manufacturing conditions. Lab-scale testing produced taste-masked particles that met the formulation targets. On the pilot scale, spray-dried particles with attributes, such as dissolution rate and particle size, of the same quality were produced, and reproducibility was also confirmed. This confirmed that the spray-dry method produced the most appropriate taste-masked particles for fast-disintegrating dosage forms.

  13. Schlieren System and method for moving objects

    NASA Technical Reports Server (NTRS)

    Weinstein, Leonard M. (Inventor)

    1995-01-01

    A system and method are provided for recording density changes in a flow field surrounding a moving object. A mask having an aperture for regulating the passage of images is placed in front of an image recording medium. An optical system is placed in front of the mask. A transition having a light field-of-view and a dark field-of-view is located beyond the test object. The optical system focuses an image of the transition at the mask such that the aperture causes a band of light to be defined on the image recording medium. The optical system further focuses an image of the object through the aperture of the mask so that the image of the object appears on the image recording medium. Relative motion is minimized between the mask and the transition. Relative motion is also minimized between the image recording medium and the image of the object. In this way, the image of the object and density changes in a flow field surrounding the object are recorded on the image recording medium when the object crosses the transition in front of the optical system.

  14. A masked negative self-esteem? Implicit and explicit self-esteem in patients with Narcissistic Personality Disorder.

    PubMed

    Marissen, Marlies A E; Brouwer, Marlies E; Hiemstra, Annemarie M F; Deen, Mathijs L; Franken, Ingmar H A

    2016-08-30

    The mask model of narcissism states that the narcissistic traits of patients with NPD are the result of a compensatory reaction to underlying ego fragility. This model assumes that high explicit self-esteem masks low implicit self-esteem. However, research on narcissism has predominantly focused on non-clinical participants and data derived from patients diagnosed with Narcissistic Personality Disorder (NPD) remain scarce. Therefore, the goal of the present study was to test the mask model hypothesis of narcissism among patients with NPD. Male patients with NPD were compared to patients with other PD's and healthy participants on implicit and explicit self-esteem. NPD patients did not differ in levels of explicit and implicit self-esteem compared to both the psychiatric and the healthy control group. Overall, the current study found no evidence in support of the mask model of narcissism among a clinical group. This implicates that it might not be relevant for clinicians to focus treatment of NPD on an underlying negative self-esteem. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. Evaluation of attenuated PSM photomask blanks with TF11 chrome and FEP-171 resist on a 248 nm DUV laser pattern generator

    NASA Astrophysics Data System (ADS)

    Xing, Kezhao; Björnborg, Charles; Karlsson, Henrik; Paulsson, Adisa; Rosendahl, Anna; Beiming, Peter; Vedenpää, Jukka; Walford, Jonathan; Newman, Tom

    2007-10-01

    Tighter requirements on mask resolution, CD and image positioning accuracy at and beyond the 45 nm technology node push the development of improved photomask blanks. One such blank for attenuated phase-shift masks (att-PSM) provides a thinner chrome film, named TF11, with higher chrome etch rate compared to the previous generation Att- PSM blank (NTAR5 chrome film) from the same supplier. Reduced stress in the chrome film also results in less image placement error induced by the material. FEP-171 is the positive chemically amplified resist (PCAR) that is most commonly used in advanced mask manufacturing with both 50 keV variable shaped e-beam (VSB) and DUV laser pattern generators. TF11 allows an FEP-171 resist film down to about 2000 Å thickness with sufficient etch resistance, while the standard resist thickness for NTAR5 is around 3000 Å. This work has experimentally evaluated the use of TF11 chrome and FEP-171 resist together with a 248 nm DUV laser pattern generator, the Sigma7500. First, patterning performance in resist with thicknesses from 2000 Å to 2600 Å, in steps of 100 Å, was tested with respect to swing curve and basic lithographic parameters including resolution, CD linearity, CD iso-dense bias and dose sensitivity. Patterning results on mask showed a swing minimum at around 2200 Å and a swing maximum at around 2500 Å, which correspond to reflectivity measurements for 248 nm wavelength performed by the blank supplier. It was concluded that the overall patterning performance was best close to the swing maximum. Thereafter the patterning performance using TF11 at two resist thicknesses, 2000 Å and 2550 Å, was studied in more detail and compared to performance using NTAR5 with 3200 Å resist. The evaluation showed that the Sigma7500-II offers good compatibility with TF11, especially using the optimized FEP-171 resist thickness of 2550 Å. It also showed that the patterning capability of the Sigma7500-II using TF11 and 2550 Å resist is improved compared to using NTAR5 and 3200 Å resist.

  16. Speech Segregation based on Binary Classification

    DTIC Science & Technology

    2016-07-15

    including the IBM, the target binary mask (TBM), the IRM, the short -time Fourier transform spectral magnitude (FFT-MAG) and its corresponding mask (FFT...complementary features and a fixed DNN as the discriminative learning machine. For evaluation metrics, besides SNR, we use the Short -Time Objective...target analysis is a recent successful intelligibility test conducted on both normal-hearing (NH) and hearing-impaired (HI) listeners. The speech

  17. Digital Images and Human Vision

    NASA Technical Reports Server (NTRS)

    Watson, Andrew B.; Null, Cynthia H. (Technical Monitor)

    1997-01-01

    Processing of digital images destined for visual consumption raises many interesting questions regarding human visual sensitivity. This talk will survey some of these questions, including some that have been answered and some that have not. There will be an emphasis upon visual masking, and a distinction will be drawn between masking due to contrast gain control processes, and due to processes such as hypothesis testing, pattern recognition, and visual search.

  18. Cortical dynamics of figure-ground segmentation: shine-through.

    PubMed

    Francis, Gregory

    2009-01-01

    The shine-through effect occurs when a brief offset vernier target is followed by a grating of non-offset vernier elements. Rather than mask the target, this stimulus sequence produces a percept of the target vernier occluding the mask elements. We analyzed the dynamics of the 3D LAMINART model of depth perception and found that it explains the appearance of shine-through for these stimuli. The model explanation proposes that shine-through is due to a combination of false binocular disparity matches between the target and the central element of the mask, and a weakening of between disparity competition due to spatial competition and boundary grouping. Simulations of the model demonstrate that its behavior closely matches empirical data on the properties of shine-through. The model is contrasted with an alternative explanation of shine-through, and novel mask conditions are studied that allow for empirical tests of the model hypotheses.

  19. Clay facial masks: physicochemical stability at different storage temperatures.

    PubMed

    Zague, Vivian; de Almeida Silva, Diego; Baby, André Rolim; Kaneko, Telma Mary; Velasco, Maria Valéria Robles

    2007-01-01

    Clay facial masks--formulations that contain a high percentage of solids dispersed in a liquid vehicle--have become of special interest due to specific properties presented by clays, such as particle size, cooling index, high adsorption capacity, and plasticity. Although most of the physicochemical properties of clay dispersions have been studied, specific aspects concerning the physicochemical stability of clay mask products remain unclear. This work aimed at investigating the accelerated physicochemical stability of clay mask formulations stored at different temperatures. Formulations were subjected to centrifuge testing and to thermal treatment for 15 days, during which temperature was varied from -5.0 degrees to 45.0 degrees C. The apparent viscosity and visual aspect (homogeneity) of all formulations were affected by temperature variation, whereas color, odor, and pH value remained unaltered. These results, besides the estimation of physicochemical stability under aging, can be useful in determining the best storage conditions for clay-based formulations.

  20. Actinic imaging and evaluation of phase structures on EUV lithography masks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mochi, Iacopo; Goldberg, Kenneth; Huh, Sungmin

    2010-09-28

    The authors describe the implementation of a phase-retrieval algorithm to reconstruct phase and complex amplitude of structures on EUV lithography masks. Many native defects commonly found on EUV reticles are difficult to detect and review accurately because they have a strong phase component. Understanding the complex amplitude of mask features is essential for predictive modeling of defect printability and defect repair. Besides printing in a stepper, the most accurate way to characterize such defects is with actinic inspection, performed at the design, EUV wavelength. Phase defect and phase structures show a distinct through-focus behavior that enables qualitative evaluation of themore » object phase from two or more high-resolution intensity measurements. For the first time, phase of structures and defects on EUV masks were quantitatively reconstructed based on aerial image measurements, using a modified version of a phase-retrieval algorithm developed to test optical phase shifting reticles.« less

  1. Combat spectacles: military testing of a new spectacle frame.

    PubMed

    Rengstorff, R H

    1985-09-01

    An improved spectacle frame has been developed for use during periods of extreme physical activity, particularly by military personnel during combat operations, and which can be used under protective face masks and headgear. The frame has a wrap-around shape, made of nylon with a contoured, recessed bridge and safety lens groove. U-shaped bridles snap on the frame front and an adjustable, interlocking strap fits over the bridles and passes under a protective mask sealing area. Field tests were conducted with 1231 soldiers at 12 military installations. Over 90% of those tested found combat spectacles were comfortable to wear, extremely durable, compatible with headgear and superior to existing military eyewear.

  2. In-die mask registration measurement on 28nm-node and beyond

    NASA Astrophysics Data System (ADS)

    Chen, Shen Hung; Cheng, Yung Feng; Chen, Ming Jui

    2013-09-01

    As semiconductor go to smaller node, the critical dimension (CD) of process become more and more small. For lithography, RET (Resolution Enhancement Technology) applications can be used for wafer printing of smaller CD/pitch on 28nm node and beyond. SMO (Source Mask Optimization), DPT (Double Patterning Technology) and SADP (Self-Align Double Patterning) can provide lower k1 value for lithography. In another way, image placement error and overlay control also become more and more important for smaller chip size (advanced node). Mask registration (image placement error) and mask overlay are important factors to affect wafer overlay control/performance especially for DPT or SADP. In traditional method, the designed registration marks (cross type, square type) with larger CD were put into scribe-line of mask frame for registration and overlay measurement. However, these patterns are far way from real patterns. It does not show the registration of real pattern directly and is not a convincing method. In this study, the in-die (in-chip) registration measurement is introduced. We extract the dummy patterns that are close to main pattern from post-OPC (Optical Proximity Correction) gds by our desired rule and choose the patterns that distribute over whole mask uniformly. The convergence test shows 100 points measurement has a reliable result.

  3. Hearing speech in music.

    PubMed

    Ekström, Seth-Reino; Borg, Erik

    2011-01-01

    The masking effect of a piano composition, played at different speeds and in different octaves, on speech-perception thresholds was investigated in 15 normal-hearing and 14 moderately-hearing-impaired subjects. Running speech (just follow conversation, JFC) testing and use of hearing aids increased the everyday validity of the findings. A comparison was made with standard audiometric noises [International Collegium of Rehabilitative Audiology (ICRA) noise and speech spectrum-filtered noise (SPN)]. All masking sounds, music or noise, were presented at the same equivalent sound level (50 dBA). The results showed a significant effect of piano performance speed and octave (P<.01). Low octave and fast tempo had the largest effect; and high octave and slow tempo, the smallest. Music had a lower masking effect than did ICRA noise with two or six speakers at normal vocal effort (P<.01) and SPN (P<.05). Subjects with hearing loss had higher masked thresholds than the normal-hearing subjects (P<.01), but there were smaller differences between masking conditions (P<.01). It is pointed out that music offers an interesting opportunity for studying masking under realistic conditions, where spectral and temporal features can be varied independently. The results have implications for composing music with vocal parts, designing acoustic environments and creating a balance between speech perception and privacy in social settings.

  4. Backward masked fearful faces enhance contralateral occipital cortical activity for visual targets within the spotlight of attention

    PubMed Central

    Reinke, Karen S.; LaMontagne, Pamela J.; Habib, Reza

    2011-01-01

    Spatial attention has been argued to be adaptive by enhancing the processing of visual stimuli within the ‘spotlight of attention’. We previously reported that crude threat cues (backward masked fearful faces) facilitate spatial attention through a network of brain regions consisting of the amygdala, anterior cingulate and contralateral visual cortex. However, results from previous functional magnetic resonance imaging (fMRI) dot-probe studies have been inconclusive regarding a fearful face-elicited contralateral modulation of visual targets. Here, we tested the hypothesis that the capture of spatial attention by crude threat cues would facilitate processing of subsequently presented visual stimuli within the masked fearful face-elicited ‘spotlight of attention’ in the contralateral visual cortex. Participants performed a backward masked fearful face dot-probe task while brain activity was measured with fMRI. Masked fearful face left visual field trials enhanced activity for spatially congruent targets in the right superior occipital gyrus, fusiform gyrus and lateral occipital complex, while masked fearful face right visual field trials enhanced activity in the left middle occipital gyrus. These data indicate that crude threat elicited spatial attention enhances the processing of subsequent visual stimuli in contralateral occipital cortex, which may occur by lowering neural activation thresholds in this retinotopic location. PMID:20702500

  5. A pattern-based method to automate mask inspection files

    NASA Astrophysics Data System (ADS)

    Kamal Baharin, Ezni Aznida Binti; Muhsain, Mohamad Fahmi Bin; Ahmad Ibrahim, Muhamad Asraf Bin; Ahmad Noorhani, Ahmad Nurul Ihsan Bin; Sweis, Jason; Lai, Ya-Chieh; Hurat, Philippe

    2017-03-01

    Mask inspection is a critical step in the mask manufacturing process in order to ensure all dimensions printed are within the needed tolerances. This becomes even more challenging as the device nodes shrink and the complexity of the tapeout increases. Thus, the amount of measurement points and their critical dimension (CD) types are increasing to ensure the quality of the mask. In addition to the mask quality, there is a significant amount of manpower needed when the preparation and debugging of this process are not automated. By utilizing a novel pattern search technology with the ability to measure and report match region scan-line (edge) measurements, we can create a flow to find, measure and mark all metrology locations of interest and provide this automated report to the mask shop for inspection. A digital library is created based on the technology product and node which contains the test patterns to be measured. This paper will discuss how these digital libraries will be generated and then utilized. As a time-critical part of the manufacturing process, this can also reduce the data preparation cycle time, minimize the amount of manual/human error in naming and measuring the various locations, reduce the risk of wrong/missing CD locations, and reduce the amount of manpower needed overall. We will also review an example pattern and how the reporting structure to the mask shop can be processed. This entire process can now be fully automated.

  6. Cross-orientation suppression in human visual cortex

    PubMed Central

    Heeger, David J.

    2011-01-01

    Cross-orientation suppression was measured in human primary visual cortex (V1) to test the normalization model. Subjects viewed vertical target gratings (of varying contrasts) with or without a superimposed horizontal mask grating (fixed contrast). We used functional magnetic resonance imaging (fMRI) to measure the activity in each of several hypothetical channels (corresponding to subpopulations of neurons) with different orientation tunings and fit these orientation-selective responses with the normalization model. For the V1 channel maximally tuned to the target orientation, responses increased with target contrast but were suppressed when the horizontal mask was added, evident as a shift in the contrast gain of this channel's responses. For the channel maximally tuned to the mask orientation, a constant baseline response was evoked for all target contrasts when the mask was absent; responses decreased with increasing target contrast when the mask was present. The normalization model provided a good fit to the contrast-response functions with and without the mask. In a control experiment, the target and mask presentations were temporally interleaved, and we found no shift in contrast gain, i.e., no evidence for suppression. We conclude that the normalization model can explain cross-orientation suppression in human visual cortex. The approach adopted here can be applied broadly to infer, simultaneously, the responses of several subpopulations of neurons in the human brain that span particular stimulus or feature spaces, and characterize their interactions. In addition, it allows us to investigate how stimuli are represented by the inferred activity of entire neural populations. PMID:21775720

  7. Early Handedness in Infancy Predicts Language Ability in Toddlers

    ERIC Educational Resources Information Center

    Nelson, Eliza L.; Campbell, Julie M.; Michel, George F.

    2014-01-01

    Researchers have long been interested in the relationship between handedness and language in development. However, traditional handedness studies using single age groups, small samples, or too few measurement time points have not capitalized on individual variability and may have masked 2 recently identified patterns in infants: those with a…

  8. Re-Examining Dissociations between Remembering and Knowing: Binary Judgments vs. Independent Ratings

    ERIC Educational Resources Information Center

    Brown, Aaron A.; Bodner, Glen E.

    2011-01-01

    When participants must classify their recognition experiences as remembering or knowing, variables often have dissociative effects on the two judgments. In contrast, when participants independently rate recollection "and" familiarity only parallel effects have been reported. To investigate this discrepancy we compared the effects of masked priming…

  9. Influence of face mask design on bag-valve-mask ventilation performance: a randomized simulation study.

    PubMed

    Na, J U; Han, S K; Choi, P C; Cho, J H; Shin, D H

    2013-10-01

    Different face mask designs can influence bag-valve-mask (BVM) ventilation performance during resuscitation. We compared a single-use, air-cushioned face mask (AM) with a reusable silicone face mask (SM) for quality of BVM ventilation on a manikin simulating cardiac arrest. Thirty-two physicians were recruited, and a prospective, randomized, crossover observational study was conducted after an American Heart Association-accredited basic life support provider course and standardized practice time were completed. Participants performed 12 cycles of BVM ventilation with both the AM and SM on a SmartMan lung simulator. Mean tidal volume was significantly higher in ventilations performed using the AM vs. the SM (548 ± 159 ml vs. 439 ± 163 ml, P < 0.01). In addition, the proportion of low-volume ventilation was significantly lower with the AM than the SM [6/12 (2-11) vs. 9/12 (5-12), P = 0.03]. Bag-valve-AM ventilation volume was not affected by the physical characteristics of the rescuers, except for sex. In contrast, bag-valve-SM ventilation volume was affected by most of the characteristics tested, including sex, height, weight, hand width, hand length, and grip power. The AM seems to be a more efficient face mask than the SM at delivering sufficient ventilation volumes. The performance of the AM did not seem to be associated with the physical characteristics of the rescuers, whereas that of the SM was affected by these factors. The SM may not be an appropriate face mask for performing one-person BVM ventilation during resuscitation for rescuers who are smaller in stature, have a smaller hand size, or have weaker grip power. © 2013 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  10. Moving stimuli are less effectively masked using traditional continuous flash suppression (CFS) compared to a moving Mondrian mask (MMM): a test case for feature-selective suppression and retinotopic adaptation.

    PubMed

    Moors, Pieter; Wagemans, Johan; de-Wit, Lee

    2014-01-01

    Continuous flash suppression (CFS) is a powerful interocular suppression technique, which is often described as an effective means to reliably suppress stimuli from visual awareness. Suppression through CFS has been assumed to depend upon a reduction in (retinotopically specific) neural adaptation caused by the continual updating of the contents of the visual input to one eye. In this study, we started from the observation that suppressing a moving stimulus through CFS appeared to be more effective when using a mask that was actually more prone to retinotopically specific neural adaptation, but in which the properties of the mask were more similar to those of the to-be-suppressed stimulus. In two experiments, we find that using a moving Mondrian mask (i.e., one that includes motion) is more effective in suppressing a moving stimulus than a regular CFS mask. The observed pattern of results cannot be explained by a simple simulation that computes the degree of retinotopically specific neural adaptation over time, suggesting that this kind of neural adaptation does not play a large role in predicting the differences between conditions in this context. We also find some evidence consistent with the idea that the most effective CFS mask is the one that matches the properties (speed) of the suppressed stimulus. These results question the general importance of retinotopically specific neural adaptation in CFS, and potentially help to explain an implicit trend in the literature to adapt one's CFS mask to match one's to-be-suppressed stimuli. Finally, the results should help to guide the methodological development of future research where continuous suppression of moving stimuli is desired.

  11. In-vivo heat retention comparison of eyelid warming masks.

    PubMed

    Bitton, Etty; Lacroix, Zoé; Léger, Stéphanie

    2016-08-01

    Meibomian gland dysfunction (MGD) is one of the most common causes of evaporative dry eye. Warm compresses (WC) are recommended as adjunct therapy to slowly transfer heat to the meibomian glands to melt or soften the stagnant meibum with targeted temperatures of 40-45°C. This clinical study evaluated the heat retention profiles of commercially available eyelid warming masks over a 12-min interval. Five eyelid-warming masks (MGDRx Eyebag(®), EyeDoctor(®), Bruder(®), Tranquileyes XR™, Thera°Pearl(®)) were heated following manufacturer's instructions and heat retention was assessed at 1-min intervals for 12min. A facecloth warmed with hot tap water was used as comparison. Twelve (n=12) subjects participated in the study (10F:2M, ranging in age from 21 to 30 with an average of 23.2±3.8years). Each mask demonstrated a unique heat retention profile, reaching maximum temperature at different times and having a different final temperature at the end of the 12-min evaluation. After heating, all eyelid warming masks reached a temperature near 37°C within the first minute. The facecloth was significantly cooler than all other masks as of the 2-min mark (p<0.05). Reusability, availability and heat retention profiles should be considered when selecting an eyelid warming masks for adjunct WC therapy in the management of MGD. All masks tested, with the exception of the facecloth, demonstrated stable heat retention throughout the 12min, bringing further awareness that patient education is required to discuss the shortcomings of the heat retention of the facecloth, if only heated once. Copyright © 2016 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  12. A threshold-based cloud mask for the high-resolution visible channel of Meteosat Second Generation SEVIRI

    NASA Astrophysics Data System (ADS)

    Bley, S.; Deneke, H.

    2013-10-01

    A threshold-based cloud mask for the high-resolution visible (HRV) channel (1 × 1 km2) of the Meteosat SEVIRI (Spinning Enhanced Visible and Infrared Imager) instrument is introduced and evaluated. It is based on operational EUMETSAT cloud mask for the low-resolution channels of SEVIRI (3 × 3 km2), which is used for the selection of suitable thresholds to ensure consistency with its results. The aim of using the HRV channel is to resolve small-scale cloud structures that cannot be detected by the low-resolution channels. We find that it is of advantage to apply thresholds relative to clear-sky reflectance composites, and to adapt the threshold regionally. Furthermore, the accuracy of the different spectral channels for thresholding and the suitability of the HRV channel are investigated for cloud detection. The case studies show different situations to demonstrate the behavior for various surface and cloud conditions. Overall, between 4 and 24% of cloudy low-resolution SEVIRI pixels are found to contain broken clouds in our test data set depending on considered region. Most of these broken pixels are classified as cloudy by EUMETSAT's cloud mask, which will likely result in an overestimate if the mask is used as an estimate of cloud fraction. The HRV cloud mask aims for small-scale convective sub-pixel clouds that are missed by the EUMETSAT cloud mask. The major limit of the HRV cloud mask is the minimum cloud optical thickness (COT) that can be detected. This threshold COT was found to be about 0.8 over ocean and 2 over land and is highly related to the albedo of the underlying surface.

  13. Annotated Bibliography for Gas Mask and Chemical Defense Gear Related Papers

    DTIC Science & Technology

    1988-01-15

    protective clothing and equipment on combat efficiency (Technical Report No. AMSAA--TR-313). Aberdeen Proving Ground, MD: Army Material Systems Analysis ...atmosphere containing a known concentration of a harmless test aerosol or gas and subsequent analysis of the concentration inside the mask. Qualitative...exercise. Ergonomics , 21, 531-538. Eleven healthy males performed steady--s:ate bicycle exercise while breathing at each of 6 added inspiratory resist

  14. Being forward not backward: lexical limits to masked priming.

    PubMed

    Davis, Chris; Kim, Jeesun; Forster, Kenneth I

    2008-05-01

    This study investigated whether masked priming is mediated by existing memory representations by determining whether nonwords targets would show repetition priming. To avoid the potential confound that nonword repetition priming would be obscured by a familiarity response bias, the standard lexical decision and naming tasks were modified to make targets unfamiliar. Participants were required to read a target string from right to left (i.e., "ECAF" should be read as "FACE") and then make a response. To examine if priming was based on lexical representations, repetition primes consisted of words when read forwards or backwards (e.g., "face", "ecaf") and nonwords (e.g., "pame", "emap"). Forward and backward primes were used to test if task instruction affected prime encoding. The lexical decision and naming tasks showed the same pattern of results: priming only occurred for forward primes with word targets (e.g., "face-ECAF"). Additional experiments to test if response priming affected the LDT indicated that the lexical status of the prime per se did not affect target responses. These results showed that the encoding of masked primes was unaffected by the novel task instruction and support the view that masked priming is due to the automatic triggering of pre-established computational processes based on stored information.

  15. Small effects of smoking on visual spatiotemporal processing.

    PubMed

    Kunchulia, Marina; Pilz, Karin S; Herzog, Michael H

    2014-12-04

    Nicotine is an important stimulant that is involved in modulating many neuronal processes, including those related to vision. Nicotine is also thought to play a key role in schizophrenia: A genetic variation of the cholinergic nicotine receptor gene, alpha-7 subunit (CHRNA7) has been shown to be associated with stronger backward masking deficits in schizophrenic patients. In this study, we tested visual backward masking in healthy smokers and non-smokers to further understand the effects of nicotine on spatiotemporal vision. In the first study, we tested 48 participants, a group of non-smokers (n = 12) and three groups of regular smokers that were either nicotine deprived (n = 12), non-deprived (n = 12) or deprived but were allowed to smoke a cigarette directly before the start of the experiment (n = 12). Performance was similar across groups, except for some small negative effects in nicotine-deprived participants. In the second study, we compared backward masking performance between regular smokers and non-smokers for older (n = 37, 13 smokers) and younger (n = 67, 21 smokers) adults. Older adults performed generally worse than younger adults but there were no significant differences in performance between smokers and non-smokers. Taken together, these findings indicate that nicotine has no long-term negative effects on visual spatiotemporal processing as determined by visual backward masking.

  16. Bitterness prediction of H1-antihistamines and prediction of masking effects of artificial sweeteners using an electronic tongue.

    PubMed

    Ito, Masanori; Ikehama, Kiyoharu; Yoshida, Koichi; Haraguchi, Tamami; Yoshida, Miyako; Wada, Koichi; Uchida, Takahiro

    2013-01-30

    The study objective was to quantitatively predict a drug's bitterness and estimate bitterness masking efficiency using an electronic tongue (e-Tongue). To verify the predicted bitterness by e-Tongue, actual bitterness scores were determined by human sensory testing. In the first study, bitterness intensities of eight H(1)-antihistamines were assessed by comparing the Euclidean distances between the drug and water. The distances seemed not to represent the drug's bitterness, but to be greatly affected by acidic taste. Two sensors were ultimately selected as best suited to bitterness evaluation, and the data obtained from the two sensors depicted the actual taste map of the eight drugs. A bitterness prediction model was established with actual bitterness scores from human sensory testing. Concerning basic bitter substances, such as H(1)-antihistamines, the predictability of bitterness intensity using e-Tongue was considered to be sufficiently promising. In another study, the bitterness masking efficiency when adding an artificial sweetener was estimated using e-Tongue. Epinastine hydrochloride aqueous solutions containing different levels of acesulfame potassium and aspartame were well discriminated by e-Tongue. The bitterness masking efficiency of epinastine hydrochloride with acesulfame potassium was successfully predicted using e-Tongue by several prediction models employed in the study. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Take a byte out of MEEF: VAMPIRE: Vehicle for Advanced Mask Pattern Inspection Readiness Evaluations

    NASA Astrophysics Data System (ADS)

    Badger, Karen D.; Rankin, Jed; Turley, Christina; Seki, Kazunori; Dechene, Dan J.; Abdelghany, Hesham

    2016-09-01

    MEEF, or Mask Error Enhancement Factor, is simply defined as the ratio of the change in printed wafer feature width to the change in mask feature width scaled to wafer level. It is important in chip manufacturing that leads to the amplification of mask errors, creating challenges with both achieving dimensional control tolerances and ensuring defect free masks, as measured by on-wafer image quality. As lithographic imaging continues to be stressed, using lower and lower k1 factor resolution enhancement techniques, the high MEEF areas present on advanced optical masks creates an environment where the need for increased mask defect sensitivity in high-MEEF areas becomes more and more critical. There are multiple approaches to mask inspection that may or may not provide enough sensitivity to detect all wafer-printable defects; the challenge in the application of these techniques is simultaneously maintaining an acceptable level of mask inspectability. The higher the MEEF, the harder the challenge will be to achieve and appropriate level of sensitivity while maintaining inspectability…and to do so on the geometries that matter. The predominant photomask fabrication inspection approach in use today compares the features on the reticle directly with the design database using high-NA optics. This approach has the ability to detect small defects, however, when inspecting aggressive OPC, it can lead to the over-detection of inconsequential, or nuisance defects. To minimize these nuisance detections, changing the sensitivity of the inspection can improve the inspectability of a mask inspected in high-NA mode, however, it leads to the inability to detect subtle, yet wafer-printable defects in High-MEEF geometry, due to the fact that this `desense' must be applied globally. There are also `lithography-emulating' approaches to inspection that use various means to provide high defect sensitivity and the ability to tolerate inconsequential, non-printing defects by using scanner-like conditions to determine which defects are wafer printable. This inspection technique is commonly referred to as being `lithography plane' or `litho plane,' since it's assessing the mask quality based on how the mask appears to the imaging optics during use, as proposed to traditional `reticle plane' inspection which is comparing the mask only with its target design. Regardless of how the defects are detected, the real question is when should they be detected? For larger technology nodes, defects are considered `statistical risks'…i.e., first they have to occur, and then they have to fall in high-MEEF areas in order to be of concern, and be below the detection limits of traditional reticle-plane inspection. In short, the `perfect storm' has to happen in order to miss printable defects using well-optimized traditional inspection approaches. The introduction of lithographic inspection techniques has revealed this statistical game is a much higher risk than originally estimated, in that very subtle waferprintable CD errors typically fall into the desense band for traditional reticle plane inspection. Because printability is largely influenced by MEEF, designs with high-MEEF values are at greater risk of traditional inspection missing printable CD errors. The question is… how high is high… and at what MEEF is optical inspection at the reticle plane sufficient? This paper will provide evaluation results for both reticle-plane and litho-plane inspections as they pertain to varying degrees of MEEF. A newly designed high-MEEF programmed defect test mask, named VAMPIRE, will be introduced. This test mask is based on 7 nm node technology and contains intentionally varying degrees of MEEF as well as a variety of programmed defects in high-MEEF environments…all of which have been verified for defect lithographic significance on a Zeiss AIMS system.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, T; Cho, M; Kang, S

    Purpose: To improve the setup accuracy of thermoplastic mask, we developed a new monitoring method based on force sensing technology and evaluated its feasibility. Methods: The thermoplastic mask setup monitoring system consists of a force sensing resistor sensor unit, a signal transport device, a control PC and an in-house software. The system is designed to monitor pressure variation between the mask and patient in real time. It also provides a warning to the user when there is a possibility of movement. A preliminary study was performed to evaluate the reliability of the sensor unit and developed monitoring system with amore » head phantom. Then, a simulation study with volunteers was conducted to evaluate the feasibility of the monitoring system. Note that the sensor unit can have multiple end-sensors and every end-sensor was confirmed to be within 2% reliability in pressure reading through a screening test. Results: To evaluate the reproducibility of the proposed monitoring system in practice, we simulated a mask setup with the head phantom. FRS sensors were attached on the face of the head phantom and pressure was monitored. For 3 repeated mask setups on the phantom, the variation of the pressure was less than 3% (only 1% larger than 2% potential uncertainty confirmed in the screening test). In the volunteer study, we intended to verify that the system could detect patient movements within the mask. Thus, volunteers were asked to turn their head or lift their chin. The system was able to detect movements effectively, confirming the clinical feasibility of the monitoring system developed. Conclusion: Through the proposed setup monitoring method, it is possible to monitor patient motion inside a mask in real time, which has never been possible with most commonly used systems using non-radiographic technology such as infrared camera system and surface imaging system. This work was supported by the Radiation Technology R&D program (No. 2013M2A2A7043498) and the Mid-career Researcher Program (2014R1A2A1A10050270) through the National Research Foundation of Korea funded by the Ministry of Science, ICT&Future Planning.« less

  19. Eye movement evidence for defocused attention in dysphoria--a perceptual span analysis.

    PubMed

    Brzezicka, Aneta; Krejtz, Izabela; von Hecker, Ulrich; Laubrock, Jochen

    2012-07-01

    The defocused attention hypothesis (von Hecker and Meiser, 2005) assumes that negative mood broadens attention, whereas the analytical rumination hypothesis (Andrews and Thompson, 2009) suggests a narrowing of the attentional focus with depression. We tested these conflicting hypotheses by directly measuring the perceptual span in groups of dysphoric and control subjects, using eye tracking. In the moving window paradigm, information outside of a variable-width gaze-contingent window was masked during reading of sentences. In measures of sentence reading time and mean fixation duration, dysphoric subjects were more pronouncedly affected than controls by a reduced window size. This difference supports the defocused attention hypothesis and seems hard to reconcile with a narrowing of attentional focus. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. Sequential dynamics of culturally moderated facial expressions of emotion.

    PubMed

    Matsumoto, David; Willingham, Bob; Olide, Andres

    2009-10-01

    There is consensus that when emotions are aroused, the displays of those emotions are either universal or culture-specific. We investigated the idea that an individual's emotional displays in a given context can be both universal and culturally variable, as they change over time. We examined the emotional displays of Olympic athletes across time, classified their expressive styles, and tested the association between those styles and a number of characteristics associated with the countries the athletes represented. Athletes from relatively urban, individualistic cultures expressed their emotions more, whereas athletes from less urban, collectivistic cultures masked their emotions more. These culturally influenced expressions occurred within a few seconds after initial, immediate, and universal emotional displays. Thus, universal and culture-specific emotional displays can unfold across time in an individual in a single context.

  1. Contrast masking in strabismic amblyopia: attenuation, noise, interocular suppression and binocular summation.

    PubMed

    Baker, Daniel H; Meese, Tim S; Hess, Robert F

    2008-07-01

    To investigate amblyopic contrast vision at threshold and above we performed pedestal-masking (contrast discrimination) experiments with a group of eight strabismic amblyopes using horizontal sinusoidal gratings (mainly 3c/deg) in monocular, binocular and dichoptic configurations balanced across eye (i.e. five conditions). With some exceptions in some observers, the four main results were as follows. (1) For the monocular and dichoptic conditions, sensitivity was less in the amblyopic eye than in the good eye at all mask contrasts. (2) Binocular and monocular dipper functions superimposed in the good eye. (3) Monocular masking functions had a normal dipper shape in the good eye, but facilitation was diminished in the amblyopic eye. (4) A less consistent result was normal facilitation in dichoptic masking when testing the good eye, but a loss of this when testing the amblyopic eye. This pattern of amblyopic results was replicated in a normal observer by placing a neutral density filter in front of one eye. The two-stage model of binocular contrast gain control [Meese, T.S., Georgeson, M.A. & Baker, D.H. (2006). Binocular contrast vision at and above threshold. Journal of Vision 6, 1224-1243.] was 'lesioned' in several ways to assess the form of the amblyopic deficit. The most successful model involves attenuation of signal and an increase in noise in the amblyopic eye, and intact stages of interocular suppression and binocular summation. This implies a behavioural influence from monocular noise in the amblyopic visual system as well as in normal observers with an ND filter over one eye.

  2. Influence of noise type on speech reception thresholds across four languages measured with matrix sentence tests.

    PubMed

    Hochmuth, Sabine; Kollmeier, Birger; Brand, Thomas; Jürgens, Tim

    2015-01-01

    To compare speech reception thresholds (SRTs) in noise using matrix sentence tests in four languages: German, Spanish, Russian, Polish. The four tests were composed of equivalent five-word sentences and were all designed and optimized using the same principles. Six stationary speech-shaped noises and three non-stationary noises were used as maskers. Forty native listeners with normal hearing: 10 for each language. SRTs were about 3 dB higher for the German and Spanish tests than for the Russian and Polish tests when stationary noise was used that matched the long-term frequency spectrum of the respective speech test materials. This general SRT difference was also observed for the other stationary noises. The within-test variability across noise conditions differed between languages. About 56% of the observed variance was predicted by the speech intelligibility index. The observed SRT benefit in fluctuating noise was similar for all tests, with a slightly smaller benefit for the Spanish test. Of the stationary noises employed, noise with the same spectrum as the speech yielded the best masking. SRT differences across languages and noises could be attributed in part to spectral differences. These findings provide the feasibility and limits of comparing audiological results across languages.

  3. Simultaneous masking between electric and acoustic stimulation in cochlear implant users with residual low-frequency hearing.

    PubMed

    Krüger, Benjamin; Büchner, Andreas; Nogueira, Waldo

    2017-09-01

    Ipsilateral electric-acoustic stimulation (EAS) is becoming increasingly important in cochlear implant (CI) treatment. Improvements in electrode designs and surgical techniques have contributed to improved hearing preservation during implantation. Consequently, CI implantation criteria have been expanded toward people with significant residual low-frequency hearing, who may benefit from the combined use of both the electric and acoustic stimulation in the same ear. However, only few studies have investigated the mutual interaction between electric and acoustic stimulation modalities. This work characterizes the interaction between both stimulation modalities using psychophysical masking experiments and cone beam computer tomography (CBCT). Two psychophysical experiments for electric and acoustic masking were performed to measure the hearing threshold elevation of a probe stimulus in the presence of a masker stimulus. For electric masking, the probe stimulus was an acoustic tone while the masker stimulus was an electric pulse train. For acoustic masking, the probe stimulus was an electric pulse train and the masker stimulus was an acoustic tone. Five EAS users, implanted with a CI and ipsilateral residual low-frequency hearing, participated in the study. Masking was determined at different electrodes and different acoustic frequencies. CBCT scans were used to determine the individual place-pitch frequencies of the intracochlear electrode contacts by using the Stakhovskaya place-to-frequency transformation. This allows the characterization of masking as a function of the difference between electric and acoustic stimulation sites, which we term the electric-acoustic frequency difference (EAFD). The results demonstrate a significant elevation of detection thresholds for both experiments. In electric masking, acoustic-tone thresholds increased exponentially with decreasing EAFD. In contrast, for the acoustic masking experiment, threshold elevations were present regardless of the tested EAFDs. Based on the present findings, we conclude that there is an asymmetry between the electric and the acoustic masker modalities. These observations have implications for the design and fitting of EAS sound-coding strategies. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. A variable-temperature nanostencil compatible with a low-temperature scanning tunneling microscope/atomic force microscope

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steurer, Wolfram, E-mail: wst@zurich.ibm.com; Gross, Leo; Schlittler, Reto R.

    2014-02-15

    We describe a nanostencil lithography tool capable of operating at variable temperatures down to 30 K. The setup is compatible with a combined low-temperature scanning tunneling microscope/atomic force microscope located within the same ultra-high-vacuum apparatus. The lateral movement capability of the mask allows the patterning of complex structures. To demonstrate operational functionality of the tool and estimate temperature drift and blurring, we fabricated LiF and NaCl nanostructures on Cu(111) at 77 K.

  5. A variable-temperature nanostencil compatible with a low-temperature scanning tunneling microscope/atomic force microscope.

    PubMed

    Steurer, Wolfram; Gross, Leo; Schlittler, Reto R; Meyer, Gerhard

    2014-02-01

    We describe a nanostencil lithography tool capable of operating at variable temperatures down to 30 K. The setup is compatible with a combined low-temperature scanning tunneling microscope/atomic force microscope located within the same ultra-high-vacuum apparatus. The lateral movement capability of the mask allows the patterning of complex structures. To demonstrate operational functionality of the tool and estimate temperature drift and blurring, we fabricated LiF and NaCl nanostructures on Cu(111) at 77 K.

  6. Analysis of public responses to preparedness policies: the cases of H1N1 influenza vaccination and gas mask distribution

    PubMed Central

    2013-01-01

    Background During several months in 2009–2010, the Israeli population was asked to take part in two preparedness programs: Acquisition of gas masks against a potential chemical-warfare attack, and vaccination against the A/H1N1 influenza pandemics. Compliance with the first request was moderate and did not attract much attention, whereas compliance with the second request was very low and was accompanied by significant controversy. The aims of this study are to compare the public’s attitudes towards these two preparedness campaigns, and to explore the roles of trust, reasoned assessment, and reflexive reactions in the public’s response to governmental preparedness policies. Methods The comparative analysis was based on a telephone survey of 2,018 respondents representing a cross-section of the adult Israeli population. Univariate analysis to describe associations of public response and attitude was performed by Chi-square tests. Findings A set of queries related to actual compliance, trust in credibility of authorities, personal opinions, reasons for non-compliance, and attitudes towards uncertainties was used to characterize the response to mask-acquisition and vaccination. In the case of mask-acquisition, the dominant response profile was of trusting compliance based on non-conditional belief in the need to adhere to the recommendation (35.6% of respondents). In the case of vaccination, the dominant response profile was of trusting non-compliance based on a reflective belief in the need for adherence (34.8% of respondents). Among the variables examined in the study, passivity was found to be the major reason for non-compliance with mask-acquisition, whereas reasoned assessment of risk played a major role in non-compliance with vaccination. Realization of the complexity in dealing with uncertainty related to developing epidemics and to newly-developed vaccines was identified in the public’s response to the H1N1 vaccination campaign. Conclusions The newly identified profile of “trusting-reflective-non-complier” individuals should be of concern to policy makers. The public is not accepting governmental recommendations in an unconditional manner. This is not driven by lack of trust in authorities, but rather by the perception of the responsibility of individuals in confronting forthcoming risks. Nevertheless, under certain conditions the public may respond in a non-reflective way and delegate this responsibly to authorities in an uncontested manner. This leaves the policy makers with the complex challenge of interacting with a passive non-involved public or alternatively with an opinionated, reflexive public. PMID:23537171

  7. An algorithm to improve speech recognition in noise for hearing-impaired listeners

    PubMed Central

    Healy, Eric W.; Yoho, Sarah E.; Wang, Yuxuan; Wang, DeLiang

    2013-01-01

    Despite considerable effort, monaural (single-microphone) algorithms capable of increasing the intelligibility of speech in noise have remained elusive. Successful development of such an algorithm is especially important for hearing-impaired (HI) listeners, given their particular difficulty in noisy backgrounds. In the current study, an algorithm based on binary masking was developed to separate speech from noise. Unlike the ideal binary mask, which requires prior knowledge of the premixed signals, the masks used to segregate speech from noise in the current study were estimated by training the algorithm on speech not used during testing. Sentences were mixed with speech-shaped noise and with babble at various signal-to-noise ratios (SNRs). Testing using normal-hearing and HI listeners indicated that intelligibility increased following processing in all conditions. These increases were larger for HI listeners, for the modulated background, and for the least-favorable SNRs. They were also often substantial, allowing several HI listeners to improve intelligibility from scores near zero to values above 70%. PMID:24116438

  8. Acute Effects of the Elevation Training Mask on Strength Performance in Recreational Weight lifters.

    PubMed

    Jagim, Andrew R; Dominy, Trevor A; Camic, Clayton L; Wright, Glenn; Doberstein, Scott; Jones, Margaret T; Oliver, Jonathan M

    2018-02-01

    Jagim, AR, Dominy, TA, Camic, CL, Wright, G, Doberstein, S, Jones, MT, and Oliver, JM. Acute effects of the elevation training mask on strength performance in recreational weightlifters. J Strength Cond Res 32(2): 482-489, 2018-The Elevation Training Mask 2.0 (ETM) is a novel device that purportedly simulates altitude training. The purpose of this study was to investigate the acute effects of the ETM on resistance exercise performance, metabolic stress markers, and ratings of mental fatigue. Twenty male recreational weight lifters completed 2 training sessions of back squat and bench press (6 sets of 10 repetitions at 85% of 5-repetition maximum and seventh set to failure) as well as a maximal effort sprint test (18% body mass) with the mask (ETM) and without the mask (NM). Training evaluation included baseline and postexercise blood lactate and oxygen saturation measures. Performance evaluation included peak and average velocity bar velocity, total volume load, total work, total repetitions completed, and sprint performance. Adverse side effects were reported in 12% (n = 3) of participants, which included feelings of light headedness, anxiety, and discomfort. No differences were found in repetitions or total workload in back squat (p = 0.07) or bench press (p = 0.08) between conditions. A lower peak velocity was identified during the back squat, bench press, and sprint test in the ETM condition (p = 0.04). Blood lactate values were lower after bench press and sprint during the ETM condition (p < 0.001). Significantly lower ratings of alertness and focus for task were found after squat, bench press, and sprint test in the ETM condition compared with the NM condition (p < 0.001). Wearing the ETM during bouts of resistance training did not hinder the ability to achieve desired training volumes during the resistance training session. However, wearing the ETM does seem to attenuate the ability to maintain working velocity during training bouts and negatively influence ratings of alertness and focus for task.

  9. In vitro and in vivo correlation of disintegration and bitter taste masking using orally disintegrating tablet containing ion exchange resin-drug complex.

    PubMed

    Kim, Jong-Il; Cho, Sang-Min; Cui, Jing-Hao; Cao, Qing-Ri; Oh, Euichaul; Lee, Beom-Jin

    2013-10-15

    Although the taste-masking of bitter drug using ion exchange resin has been recognized, in vitro testing using an electronic tongue (e-Tongue) and in vivo bitterness test by human panel test was not fully understood. In case of orally disintegrating tablet (ODT) containing bitter medicine, in vitro and in vivo disintegration is also importance for dosage performance. Donepezil hydrochloride was chosen as a model drug due to its bitterness and requires rapid disintegration for the preparation of ODT. In this study, ion exchange resin drug complex (IRDC) at three different ratios (1:2, 1:1, 2:1) was prepared using a spray-drying method and then IRDC-loaded ODT containing superdisintegrants (crospovidone, croscarmellose sodium, and sodium starch glycolate) were prepared by the direct compression method. The physical properties and morphologies were then characterized by scanning electron microscopy (SEM), X-ray powder diffraction (PXRD) and electrophoretic laser scattering (ELS), respectively. The in vitro taste-masking efficiency was measured with an electronic tongue (e-Tongue). In vivo bitterness scale was also evaluated by human volunteers and then we defined new term, "bitterness index (BI)" to link in vitro e-Tongue. There was a good correlation of IRDC between in vitro e-Tongue values and in vivo BI. Furthermore, IRDC-loaded ODT showed good in vitro/in vivo correlation in the disintegration time. The optimal IRDC-loaded ODTs displayed similar drug release profiles to the reference tablet (Aricept(®) ODT) in release media of pH 1.2, pH 4.0, pH 6.8 and distilled water but had significantly better palatability in vivo taste-masking evaluation. The current IRDC-loaded ODT according to the in vitro and in vivo correlation of disintegration and bitter taste masking could provide platforms in ODT dosage formulations of donepezil hydrochloride for improved patient compliances. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. High Reading Skills Mask Dyslexia in Gifted Children.

    PubMed

    van Viersen, Sietske; Kroesbergen, Evelyn H; Slot, Esther M; de Bree, Elise H

    2016-01-01

    This study investigated how gifted children with dyslexia might be able to mask literacy problems and the role of possible compensatory mechanisms. The sample consisted of 121 Dutch primary school children that were divided over four groups (typically developing [TD] children, children with dyslexia, gifted children, gifted children with dyslexia). The test battery included measures of literacy (reading/spelling) and cognitive abilities related to literacy and language (phonological awareness [PA], rapid automatized naming [RAN], verbal short-term memory [VSTM], working memory [WM], grammar, and vocabulary). It was hypothesized that gifted children with dyslexia would outperform children with dyslexia on literacy tests. In addition, a core-deficit model including dyslexia-related weaknesses and a compensational model involving giftedness-related strengths were tested using Bayesian statistics to explain their reading/spelling performance. Gifted children with dyslexia performed on all literacy tests in between children with dyslexia and TD children. Their cognitive profile showed signs of weaknesses in PA and RAN and strengths in VSTM, WM, and language skills. Findings indicate that phonology is a risk factor for gifted children with dyslexia, but this is moderated by other skills such as WM, grammar, and vocabulary, providing opportunities for compensation of a cognitive deficit and masking of literacy difficulties. © Hammill Institute on Disabilities 2014.

  11. Timing Analysis with INTEGRAL: Comparing Different Reconstruction Algorithms

    NASA Technical Reports Server (NTRS)

    Grinberg, V.; Kreykenboehm, I.; Fuerst, F.; Wilms, J.; Pottschmidt, K.; Bel, M. Cadolle; Rodriquez, J.; Marcu, D. M.; Suchy, S.; Markowitz, A.; hide

    2010-01-01

    INTEGRAL is one of the few instruments capable of detecting X-rays above 20keV. It is therefore in principle well suited for studying X-ray variability in this regime. Because INTEGRAL uses coded mask instruments for imaging, the reconstruction of light curves of X-ray sources is highly non-trivial. We present results from the comparison of two commonly employed algorithms, which primarily measure flux from mask deconvolution (ii-lc-extract) and from calculating the pixel illuminated fraction (ii-light). Both methods agree well for timescales above about 10 s, the highest time resolution for which image reconstruction is possible. For higher time resolution, ii-light produces meaningful results, although the overall variance of the lightcurves is not preserved.

  12. A new predictive model for continuous positive airway pressure in the treatment of obstructive sleep apnea.

    PubMed

    Ebben, Matthew R; Narizhnaya, Mariya; Krieger, Ana C

    2017-05-01

    Numerous mathematical formulas have been developed to determine continuous positive airway pressure (CPAP) without an in-laboratory titration study. Recent studies have shown that style of CPAP mask can affect the optimal pressure requirement. However, none of the current models take mask style into account. Therefore, the goal of this study was to develop new predictive models of CPAP that take into account the style of mask interface. Data from 200 subjects with attended CPAP titrations during overnight polysomnograms using nasal masks and 132 subjects using oronasal masks were randomized and split into either a model development or validation group. Predictive models were then created in each model development group and the accuracy of the models was then tested in the model validation groups. The correlation between our new oronasal model and laboratory determined optimal CPAP was significant, r = 0.61, p < 0.001. Our nasal formula was also significantly related to laboratory determined optimal CPAP, r = 0.35, p < 0.001. The oronasal model created in our study significantly outperformed the original CPAP predictive model developed by Miljeteig and Hoffstein, z = 1.99, p < 0.05. The predictive performance of our new nasal model did not differ significantly from Miljeteig and Hoffstein's original model, z = -0.16, p < 0.90. The best predictors for the nasal mask group were AHI, lowest SaO2, and neck size, whereas the top predictors in the oronasal group were AHI and lowest SaO2. Our data show that predictive models of CPAP that take into account mask style can significantly improve the formula's accuracy. Most of the past models likely focused on model development with nasal masks (mask style used for model development was not typically reported in previous investigations) and are not well suited for patients using an oronasal interface. Our new oronasal CPAP prediction equation produced significantly improved performance compared to the well-known Miljeteig and Hoffstein formula in patients titrated on CPAP with an oronasal mask and was also significantly related to laboratory determined optimal CPAP.

  13. Change in the magnitude and mechanisms of global temperature variability with warming.

    PubMed

    Brown, Patrick T; Ming, Yi; Li, Wenhong; Hill, Spencer A

    2017-01-01

    Natural unforced variability in global mean surface air temperature (GMST) can mask or exaggerate human-caused global warming, and thus a complete understanding of this variability is highly desirable. Significant progress has been made in elucidating the magnitude and physical origins of present-day unforced GMST variability, but it has remained unclear how such variability may change as the climate warms. Here we present modeling evidence that indicates that the magnitude of low-frequency GMST variability is likely to decline in a warmer climate and that its generating mechanisms may be fundamentally altered. In particular, a warmer climate results in lower albedo at high latitudes, which yields a weaker albedo feedback on unforced GMST variability. These results imply that unforced GMST variability is dependent on the background climatological conditions, and thus climate model control simulations run under perpetual preindustrial conditions may have only limited relevance for understanding the unforced GMST variability of the future.

  14. Change in the Magnitude and Mechanisms of Global Temperature Variability with Warming

    NASA Astrophysics Data System (ADS)

    Brown, P. T.; Ming, Y.; Li, W.; Hill, S. A.

    2017-12-01

    Natural unforced variability in global mean surface air temperature (GMST) can mask or exaggerate human-caused global warming, and thus a complete understanding of this variability is highly desirable. Significant progress has been made in elucidating the magnitude and physical origins of present-day unforced GMST variability, but it has remained unclear how such variability may change as the climate warms. Here we present modeling evidence that indicates that the magnitude of low-frequency GMST variability is likely to decline in a warmer climate and that its generating mechanisms may be fundamentally altered. In particular, a warmer climate results in lower albedo at high latitudes, which yields a weaker albedo feedback on unforced GMST variability. These results imply that unforced GMST variability is dependent on the background climatological conditions, and thus climate model control simulations run under perpetual preindustrial conditions may have only limited relevance for understanding the unforced GMST variability of the future.

  15. Neurophysiological model of tinnitus: dependence of the minimal masking level on treatment outcome.

    PubMed

    Jastreboff, P J; Hazell, J W; Graham, R L

    1994-11-01

    Validity of the neurophysiological model of tinnitus (Jastreboff, 1990), outlined in this paper, was tested on data from multicenter trial of tinnitus masking (Hazell et al., 1985). Minimal masking level, intensity match of tinnitus, and the threshold of hearing have been evaluated on a total of 382 patients before and after 6 months of treatment with maskers, hearing aids, or combination devices. The data has been divided into categories depending on treatment outcome and type of approach used. Results of analysis revealed that: i) the psychoacoustical description of tinnitus does not possess a predictive value for the outcome of the treatment; ii) minimal masking level changed significantly depending on the treatment outcome, decreasing on average by 5.3 dB in patients reporting improvement, and increasing by 4.9 dB in those whose tinnitus remained the same or worsened; iii) 73.9% of patients reporting improvement had their minimal masking level decreased as compared with 50.5% for patients not showing improvement, which is at the level of random change; iv) the type of device used has no significant impact on the treatment outcome and minimal masking level change; v) intensity match and threshold of hearing did not exhibit any significant changes which can be related to treatment outcome. These results are fully consistent with the neurophysiological interpretation of mechanisms involved in the phenomenon of tinnitus and its alleviation.

  16. A method of alignment masking for refining the phylogenetic signal of multiple sequence alignments.

    PubMed

    Rajan, Vaibhav

    2013-03-01

    Inaccurate inference of positional homologies in multiple sequence alignments and systematic errors introduced by alignment heuristics obfuscate phylogenetic inference. Alignment masking, the elimination of phylogenetically uninformative or misleading sites from an alignment before phylogenetic analysis, is a common practice in phylogenetic analysis. Although masking is often done manually, automated methods are necessary to handle the much larger data sets being prepared today. In this study, we introduce the concept of subsplits and demonstrate their use in extracting phylogenetic signal from alignments. We design a clustering approach for alignment masking where each cluster contains similar columns-similarity being defined on the basis of compatible subsplits; our approach then identifies noisy clusters and eliminates them. Trees inferred from the columns in the retained clusters are found to be topologically closer to the reference trees. We test our method on numerous standard benchmarks (both synthetic and biological data sets) and compare its performance with other methods of alignment masking. We find that our method can eliminate sites more accurately than other methods, particularly on divergent data, and can improve the topologies of the inferred trees in likelihood-based analyses. Software available upon request from the author.

  17. Lateralization of kin recognition signals in the human face

    PubMed Central

    Dal Martello, Maria F.; Maloney, Laurence T.

    2010-01-01

    When human subjects view photographs of faces, their judgments of identity, gender, emotion, age, and attractiveness depend more on one side of the face than the other. We report an experiment testing whether allocentric kin recognition (the ability to judge the degree of kinship between individuals other than the observer) is also lateralized. One hundred and twenty-four observers judged whether or not pairs of children were biological siblings by looking at photographs of their faces. In three separate conditions, (1) the right hemi-face was masked, (2) the left hemi-face was masked, or (3) the face was fully visible. The d′ measures for the masked left hemi-face and masked right hemi-face were 1.024 and 1.004, respectively (no significant difference), and the d′ measure for the unmasked face was 1.079, not significantly greater than that for either of the masked conditions. We conclude, first, that there is no superiority of one or the other side of the observed face in kin recognition, second, that the information present in the left and right hemi-faces relevant to recognizing kin is completely redundant, and last that symmetry cues are not used for kin recognition. PMID:20884584

  18. A robust threshold-based cloud mask for the HRV channel of MSG SEVIRI

    NASA Astrophysics Data System (ADS)

    Bley, S.; Deneke, H.

    2013-03-01

    A robust threshold-based cloud mask for the high-resolution visible (HRV) channel (1 × 1 km2) of the METEOSAT SEVIRI instrument is introduced and evaluated. It is based on operational EUMETSAT cloud mask for the low resolution channels of SEVIRI (3 × 3 km2), which is used for the selection of suitable thresholds to ensure consistency with its results. The aim of using the HRV channel is to resolve small-scale cloud structures which cannot be detected by the low resolution channels. We find that it is of advantage to apply thresholds relative to clear-sky reflectance composites, and to adapt the threshold regionally. Furthermore, the accuracy of the different spectral channels for thresholding and the suitability of the HRV channel are investigated for cloud detection. The case studies show different situations to demonstrate the behaviour for various surface and cloud conditions. Overall, between 4 and 24% of cloudy low-resolution SEVIRI pixels are found to contain broken clouds in our test dataset depending on considered region. Most of these broken pixels are classified as cloudy by EUMETSAT's cloud mask, which will likely result in an overestimate if the mask is used as estimate of cloud fraction.

  19. A prototype urine collection device for female aircrew

    NASA Technical Reports Server (NTRS)

    Bisson, Roger U.; Delger, Karlyna L.

    1993-01-01

    Women are gaining increased access to small military cockpits. This shift has stimulated the search for practical urine containment and disposal methods for female aircrew. There are no external urine collection devices (UCD) for women that are comfortable, convenient, and leak free. We describe a prototype UCD that begins to meet this need. Materials used to make custom aviator masks were adapted to mold a perineal mask. First, a perineal cast (negative) was used to make a mold (positive). Next, a perineal mask made of wax was formed to fit the positive mold. Finally, a soft, pliable perineal mask was fabricated using the wax model as a guide. The prototype was tested for comfort, fit, and leakage. In the sitting position, less than 5 cc of urine leakage occurred with each 600 cc of urine collected. Comfort was mostly satisfactory, but ambulation was limited and the outlet design could lead to kinking and obstruction. We concluded that a perineal mask may serve as a comfortable and functional external UCD acceptable for use by females in confined environments. Changes are needed to improve comfort, fit, and urine drainage. Integration into cockpits, pressure suits, chemical defense gear, and environments where access to relief facilities is restricted is planned.

  20. Reducing personal exposure to particulate air pollution improves cardiovascular health in patients with coronary heart disease.

    PubMed

    Langrish, Jeremy P; Li, Xi; Wang, Shengfeng; Lee, Matthew M Y; Barnes, Gareth D; Miller, Mark R; Cassee, Flemming R; Boon, Nicholas A; Donaldson, Ken; Li, Jing; Li, Liming; Mills, Nicholas L; Newby, David E; Jiang, Lixin

    2012-03-01

    Air pollution exposure increases cardiovascular morbidity and mortality and is a major global public health concern. We investigated the benefits of reducing personal exposure to urban air pollution in patients with coronary heart disease. In an open randomized crossover trial, 98 patients with coronary heart disease walked on a predefined route in central Beijing, China, under different conditions: once while using a highly efficient face mask, and once while not using the mask. Symptoms, exercise, personal air pollution exposure, blood pressure, heart rate, and 12-lead electrocardiography were monitored throughout the 24-hr study period. Ambient air pollutants were dominated by fine and ultrafine particulate matter (PM) that was present at high levels [74 μg/m³ for PM(2.5) (PM with aerodynamic diamater <2.5 µm)]. Consistent with traffic-derived sources, this PM contained organic carbon and polycyclic aromatic hydrocarbons and was highly oxidizing, generating large amounts of free radicals. The face mask was well tolerated, and its use was associated with decreased self-reported symptoms and reduced maximal ST segment depression (-142 vs. -156 μV, p = 0.046) over the 24-hr period. When the face mask was used during the prescribed walk, mean arterial pressure was lower (93 ± 10 vs. 96 ± 10 mmHg, p = 0.025) and heart rate variability increased (high-frequency power: 54 vs. 40 msec², p = 0.005; high-frequency normalized power: 23.5 vs. 20.5 msec, p = 0.001; root mean square successive differences: 16.7 vs. 14.8 msec, p = 0.007). However, mask use did not appear to influence heart rate or energy expenditure. Reducing personal exposure to air pollution using a highly efficient face mask appeared to reduce symptoms and improve a range of cardiovascular health measures in patients with coronary heart disease. Such interventions to reduce personal exposure to PM air pollution have the potential to reduce the incidence of cardiovascular events in this highly susceptible population.

  1. Alternative method for variable aspect ratio vias using a vortex mask

    NASA Astrophysics Data System (ADS)

    Schepis, Anthony R.; Levinson, Zac; Burbine, Andrew; Smith, Bruce W.

    2014-03-01

    Historically IC (integrated circuit) device scaling has bridged the gap between technology nodes. Device size reduction is enabled by increased pattern density, enhancing functionality and effectively reducing cost per chip. Exemplifying this trend are aggressive reductions in memory cell sizes that have resulted in systems with diminishing area between bit/word lines. This affords an even greater challenge in the patterning of contact level features that are inherently difficult to resolve because of their relatively small area and complex aerial image. To accommodate these trends, semiconductor device design has shifted toward the implementation of elliptical contact features. This empowers designers to maximize the use of free device space, preserving contact area and effectively reducing the via dimension just along a single axis. It is therefore critical to provide methods that enhance the resolving capacity of varying aspect ratio vias for implementation in electronic design systems. Vortex masks, characterized by their helically induced propagation of light and consequent dark core, afford great potential for the patterning of such features when coupled with a high resolution negative tone resist system. This study investigates the integration of a vortex mask in a 193nm immersion (193i) lithography system and qualifies its ability to augment aspect ratio through feature density using aerial image vector simulation. It was found that vortex fabricated vias provide a distinct resolution advantage over traditionally patterned contact features employing a 6% attenuated phase shift mask (APM). 1:1 features were resolvable at 110nm pitch with a 38nm critical dimension (CD) and 110nm depth of focus (DOF) at 10% exposure latitude (EL). Furthermore, iterative source-mask optimization was executed as means to augment aspect ratio. By employing mask asymmetries and directionally biased sources aspect ratios ranging between 1:1 and 2:1 were achievable, however, this range is ultimately dictated by pitch employed.

  2. The retention and disruption of color information in human short-term visual memory.

    PubMed

    Nemes, Vanda A; Parry, Neil R A; Whitaker, David; McKeefry, Declan J

    2012-01-27

    Previous studies have demonstrated that the retention of information in short-term visual perceptual memory can be disrupted by the presentation of masking stimuli during interstimulus intervals (ISIs) in delayed discrimination tasks (S. Magnussen & W. W. Greenlee, 1999). We have exploited this effect in order to determine to what extent short-term perceptual memory is selective for stimulus color. We employed a delayed hue discrimination paradigm to measure the fidelity with which color information was retained in short-term memory. The task required 5 color normal observers to discriminate between spatially non-overlapping colored reference and test stimuli that were temporally separated by an ISI of 5 s. The points of subjective equality (PSEs) on the resultant psychometric matching functions provided an index of performance. Measurements were made in the presence and absence of mask stimuli presented during the ISI, which varied in hue around the equiluminant plane in DKL color space. For all reference stimuli, we found a consistent mask-induced, hue-dependent shift in PSE compared to the "no mask" conditions. These shifts were found to be tuned in color space, only occurring for a range of mask hues that fell within bandwidths of 29-37 deg. Outside this range, masking stimuli had little or no effect on measured PSEs. The results demonstrate that memory masking for color exhibits selectivity similar to that which has already been demonstrated for other visual attributes. The relatively narrow tuning of these interference effects suggests that short-term perceptual memory for color is based on higher order, non-linear color coding. © ARVO

  3. Preclinical in vitro activity of QR-435 against influenza A virus as a virucide and in paper masks for prevention of viral transmission.

    PubMed

    Oxford, John S; Lambkin, Robert; Guralnik, Mario; Rosenbloom, Richard A; Petteruti, Michael P; Digian, Kelly; Lefante, Carolyn

    2007-01-01

    Prophylaxis against influenza is difficult, and current approaches against pandemics may be ineffective because of shortages of the two proven classes of antivirals in the face of a large-scale infection. Herbal/natural products may represent an effective alternative to conventional attempts to protect against infection by avian influenza virus. QR-435, an all-natural compound of green tea extract and other agents, has been developed to provide protection against a wide range of viral infections. The antiviral activities of several QR-435 preparations as well as QR-435 (1) green tea extract were tested against A/Sydney/5/97 and A/Panama-Resvir 17 strains of avian influenza virus H3N2 by means of an assay based on Madin-Darby canine kidney cells. Toxic effects of QR-435 formulations on these cells were also evaluated as were the virucidal properties of a commercially available mask impregnated with QR-435. The efficacy of a QR-435/mask combination was compared with that of the QR control/mask combination, an untreated mask, and no mask. QR-435 had significant in vitro activity against H3N2 at concentrations that were not associated with significant cellular toxic effects. The antiviral activity of QR-435 (1) was similar to that of QR-435. Masks impregnated with QR-435 were highly effective in blocking the passage of live H3N2 virus. These preclinical results warrant further evaluation of the prophylactic use of QR-435 against viral infection in humans.

  4. Semantic priming effects from single words in a lexical decision task.

    PubMed

    Noguera, Carmen; Ortells, Juan J; Abad, María J F; Carmona, Encarnación; Daza, M Teresa

    2007-06-01

    The present research examines the semantic priming effects of a centrally presented single prime word to which participants were instructed to either "attend and remember" or "ignore". The prime word was followed by a central probe target on which the participants made a lexical decision task. The main variables manipulated across experiments were prime duration (50 or 100 ms), the presence or absence of a mask following the prime, and the presence (or absence) and type of distractor stimulus (random set of consonants or pseudowords) on the probe display. There was a consistent interaction between the instructions and the semantic priming effects. Relative to the "attend and remember" instruction, an "ignore" instruction produced reduced positive priming from single primes presented for 100 ms, irrespective of the presence or absence of a prime mask, and regardless of whether the probe target was presented with or without distractors. Additionally, reliable negative priming was found from ignored primes presented for briefer durations (50 ms) and immediately followed by a mask. Methodological and theoretical implications of the present findings for the extant negative priming literature are discussed.

  5. PERSONNEL - PREFLIGHT - APOLLO-SOYUZ TEST PROJECT (ASTP) - EL-BAZ, FAROUK - JSC

    NASA Image and Video Library

    1975-07-08

    S75-28229 (8 July 1975) --- The three American ASTP prime crew astronauts participate in a photography mission briefing in Building 5 with Dr. Farouk El-Baz (wearing face mask) during Apollo-Soyuz Test Project preflight activity at NASA's Johnson Space Center. They are, left to right, Thomas P. Stafford, commander; Vance D. Brand, command module pilot; Dr. El-Baz; and Donald K. Slayton, docking module pilot. Dr. El-Baz is with the Center for Earth and Planetary Studies, National Air and Space Museum, Smithsonian Institution. The face mask is to protect the crewmen from possible exposure to disease prior to launch time. Photo credit: NASA

  6. Spatial Release from Masking in Children: Effects of Simulated Unilateral Hearing Loss

    PubMed Central

    Corbin, Nicole E.; Buss, Emily; Leibold, Lori J.

    2016-01-01

    Objectives The purpose of this study was twofold: 1) to determine the effect of an acute simulated unilateral hearing loss on children’s spatial release from masking in two-talker speech and speech-shaped noise, and 2) to develop a procedure to be used in future studies that will assess spatial release from masking in children who have permanent unilateral hearing loss. There were three main predictions. First, spatial release from masking was expected to be larger in two-talker speech than speech-shaped noise. Second, simulated unilateral hearing loss was expected to worsen performance in all listening conditions, but particularly in the spatially separated two-talker speech masker. Third, spatial release from masking was expected to be smaller for children than for adults in the two-talker masker. Design Participants were 12 children (8.7 to 10.9 yrs) and 11 adults (18.5 to 30.4 yrs) with normal bilateral hearing. Thresholds for 50%-correct recognition of Bamford-Kowal-Bench sentences were measured adaptively in continuous two-talker speech or speech-shaped noise. Target sentences were always presented from a loudspeaker at 0° azimuth. The masker stimulus was either co-located with the target or spatially separated to +90° or −90° azimuth. Spatial release from masking was quantified as the difference between thresholds obtained when the target and masker were co-located and thresholds obtained when the masker was presented from +90° or − 90°. Testing was completed both with and without a moderate simulated unilateral hearing loss, created with a foam earplug and supra-aural earmuff. A repeated-measures design was used to compare performance between children and adults, and performance in the no-plug and simulated-unilateral-hearing-loss conditions. Results All listeners benefited from spatial separation of target and masker stimuli on the azimuth plane in the no-plug listening conditions; this benefit was larger in two-talker speech than in speech-shaped noise. In the simulated-unilateral-hearing-loss conditions, a positive spatial release from masking was observed only when the masker was presented ipsilateral to the simulated unilateral hearing loss. In the speech-shaped noise masker, spatial release from masking in the no-plug condition was similar to that obtained when the masker was presented ipsilateral to the simulated unilateral hearing loss. In contrast, in the two-talker speech masker, spatial release from masking in the no-plug condition was much larger than that obtained when the masker was presented ipsilateral to the simulated unilateral hearing loss. When either masker was presented contralateral to the simulated unilateral hearing loss, spatial release from masking was negative. This pattern of results was observed for both children and adults, although children performed more poorly overall. Conclusions Children and adults with normal bilateral hearing experience greater spatial release from masking for a two-talker speech than a speech-shaped noise masker. Testing in a two-talker speech masker revealed listening difficulties in the presence of disrupted binaural input that were not observed in a speech-shaped noise masker. This procedure offers promise for the assessment of spatial release from masking in children with permanent unilateral hearing loss. PMID:27787392

  7. Citric Acid Suppresses the Bitter Taste of Olopatadine Hydrochloride Orally Disintegrating Tablets.

    PubMed

    Sotoyama, Mai; Uchida, Shinya; Tanaka, Shimako; Hakamata, Akio; Odagiri, Keiichi; Inui, Naoki; Watanabe, Hiroshi; Namiki, Noriyuki

    2017-01-01

    Orally disintegrating tablets (ODTs) are formulated to disintegrate upon contact with saliva, allowing administration without water. Olopatadine hydrochloride, a second-generation antihistamine, is widely used for treating allergic rhinitis. However, it has a bitter taste; therefore, the development of taste-masked olopatadine ODTs is essential. Some studies have suggested that citric acid could suppress the bitterness of drugs. However, these experiments were performed using solutions, and the taste-masking effect of citric acid on ODTs has not been evaluated using human gustatory sensation tests. Thus, this study evaluated citric acid's taste-masking effect on olopatadine ODTs. Six types of olopatadine ODTs containing 0-10% citric acid were prepared and subjected to gustatory sensation tests that were scored using the visual analog scale. The bitterness and overall palatability of olopatadine ODTs during disintegration in the mouth and after spitting out were evaluated in 11 healthy volunteers (age: 22.8±2.2 years). The hardness of the ODTs was >50 N. Disintegration time and dissolution did not differ among the different ODTs. The results of the gustatory sensation tests suggest that citric acid could suppress the bitterness of olopatadine ODTs in a dose-dependent manner. Olopatadine ODTs with a high content of citric acid (5-10%) showed poorer overall palatability than that of those without citric acid despite the bitterness suppression. ODTs containing 2.5% citric acid, yogurt flavoring, and aspartame were the most suitable formulations since they showed low bitterness and good overall palatability. Thus, citric acid is an effective bitterness-masking option for ODTs.

  8. Mycobacterium tuberculosis transmission rates in a sanatorium: implications for new preventive guidelines.

    PubMed

    Jernigan, J A; Adal, K A; Anglim, A M; Byers, K E; Farr, B M

    1994-12-01

    In 1990, the Centers for Disease Control and Prevention recommended substituting dust-mist particulate respirators for simple isolation masks in acid-fast bacillus isolation rooms, reasoning that air leaks around the simple masks could result in a higher rate of purified protein derivative skin-test conversion. In 1993, a Centers for Disease Control and Prevention draft guideline proposed that high-efficiency particulate air filter respirators be used instead of dust-mist particulate respirators. Epidemiologic data were not available to assess the importance of these changes or their cost-effectiveness. The University of Virginia was affiliated with a tuberculosis hospital from 1979 until 1987. We surveyed physicians who had served as residents in internal medicine during this period regarding purified protein derivative skin-test history. duration of work at the tuberculosis sanatorium, and any history of unprotected exposures to patients with active pulmonary or laryngeal tuberculosis. Patients with active tuberculosis at the sanatorium were isolated in negative-pressure rooms with UV lights. Physicians wore simple isolation masks in these rooms. Responses were received from 83 former resident physicians. Fifty-two physicians had worked on the tuberculosis wards for a total of 420 weeks, with no subsequent skin-test conversions (95% CI 0 to 1 conversion/8 physician-years). These data document a low risk of occupational transmission of Mycobacterium tuberculosis to physicians who wear simple isolation masks in negative-pressure ventilation rooms with UV lights. This low rate predicts that the additional protective efficacy and cost-effectiveness of the more expensive high-efficiency particulate air filter respirators and the respiratory protection program will be low.

  9. Does letter rotation slow down orthographic processing in word recognition?

    PubMed

    Perea, Manuel; Marcet, Ana; Fernández-López, María

    2018-02-01

    Leading neural models of visual word recognition assume that letter rotation slows down the conversion of the visual input to a stable orthographic representation (e.g., local detectors combination model; Dehaene, Cohen, Sigman, & Vinckier, 2005, Trends in Cognitive Sciences, 9, 335-341). If this premise is true, briefly presented rotated primes should be less effective at activating word representations than those primes with upright letters. To test this question, we conducted a masked priming lexical decision experiment with vertically presented words either rotated 90° or in marquee format (i.e., vertically but with upright letters). We examined the impact of the format on both letter identity (masked identity priming: identity vs. unrelated) and letter position (masked transposed-letter priming: transposed-letter prime vs. replacement-letter prime). Results revealed sizeable masked identity and transposed-letter priming effects that were similar in magnitude for rotated and marquee words. Therefore, the reading cost from letter rotation does not arise in the initial access to orthographic/lexical representations.

  10. The development of the Laryngeal Mask--a brief history of the invention, early clinical studies and experimental work from which the Laryngeal Mask evolved.

    PubMed

    Brain, A I

    1991-01-01

    The history of the invention and development of the Laryngeal Mask in the East End of London during the years 1981-88 is briefly described. The concept evolved from home-made prototypes built from the Goldman Dental Mask through a complex series of one-off latex models culminating in a primitive factory-made silicone cuff in 1986. This work defined the design parameters necessary to reconcile the needs for safety, reliability and ease of insertion while at the same time exploring the limits to possible use. In early 1988 the final version was tested by the inventor who had by this time used the device in more than 7500 patients undergoing routine surgery. From this experience a number of important lessons were learned relating to safe and effective use, which are summarized in the inventor's Instruction Manual. The importance of referring to this volume before use is stressed.

  11. Parallel compression/decompression-based datapath architecture for multibeam mask writers

    NASA Astrophysics Data System (ADS)

    Chaudhary, Narendra; Savari, Serap A.

    2017-06-01

    Multibeam electron beam systems will be used in the future for mask writing and for complimentary lithography. The major challenges of the multibeam systems are in meeting throughput requirements and in handling the large data volumes associated with writing grayscale data on the wafer. In terms of future communications and computational requirements Amdahl's Law suggests that a simple increase of computation power and parallelism may not be a sustainable solution. We propose a parallel data compression algorithm to exploit the sparsity of mask data and a grayscale video-like representation of data. To improve the communication and computational efficiency of these systems at the write time we propose an alternate datapath architecture partly motivated by multibeam direct write lithography and partly motivated by the circuit testing literature, where parallel decompression reduces clock cycles. We explain a deflection plate architecture inspired by NuFlare Technology's multibeam mask writing system and how our datapath architecture can be easily added to it to improve performance.

  12. Parallel compression/decompression-based datapath architecture for multibeam mask writers

    NASA Astrophysics Data System (ADS)

    Chaudhary, Narendra; Savari, Serap A.

    2017-10-01

    Multibeam electron beam systems will be used in the future for mask writing and for complementary lithography. The major challenges of the multibeam systems are in meeting throughput requirements and in handling the large data volumes associated with writing grayscale data on the wafer. In terms of future communications and computational requirements, Amdahl's law suggests that a simple increase of computation power and parallelism may not be a sustainable solution. We propose a parallel data compression algorithm to exploit the sparsity of mask data and a grayscale video-like representation of data. To improve the communication and computational efficiency of these systems at the write time, we propose an alternate datapath architecture partly motivated by multibeam direct-write lithography and partly motivated by the circuit testing literature, where parallel decompression reduces clock cycles. We explain a deflection plate architecture inspired by NuFlare Technology's multibeam mask writing system and how our datapath architecture can be easily added to it to improve performance.

  13. Controlling bridging and pinching with pixel-based mask for inverse lithography

    NASA Astrophysics Data System (ADS)

    Kobelkov, Sergey; Tritchkov, Alexander; Han, JiWan

    2016-03-01

    Inverse Lithography Technology (ILT) has become a viable computational lithography candidate in recent years as it can produce mask output that results in process latitude and CD control in the fab that is hard to match with conventional OPC/SRAF insertion approaches. An approach to solving the inverse lithography problem as a nonlinear, constrained minimization problem over a domain mask pixels was suggested in the paper by Y. Granik "Fast pixel-based mask optimization for inverse lithography" in 2006. The present paper extends this method to satisfy bridging and pinching constraints imposed on print contours. Namely, there are suggested objective functions expressing penalty for constraints violations, and their minimization with gradient descent methods is considered. This approach has been tested with an ILT-based Local Printability Enhancement (LPTM) tool in an automated flow to eliminate hotspots that can be present on the full chip after conventional SRAF placement/OPC and has been applied in 14nm, 10nm node production, single and multiple-patterning flows.

  14. Comparison of OPC job prioritization schemes to generate data for mask manufacturing

    NASA Astrophysics Data System (ADS)

    Lewis, Travis; Veeraraghavan, Vijay; Jantzen, Kenneth; Kim, Stephen; Park, Minyoung; Russell, Gordon; Simmons, Mark

    2015-03-01

    Delivering mask ready OPC corrected data to the mask shop on-time is critical for a foundry to meet the cycle time commitment for a new product. With current OPC compute resource sharing technology, different job scheduling algorithms are possible, such as, priority based resource allocation and fair share resource allocation. In order to maximize computer cluster efficiency, minimize the cost of the data processing and deliver data on schedule, the trade-offs of each scheduling algorithm need to be understood. Using actual production jobs, each of the scheduling algorithms will be tested in a production tape-out environment. Each scheduling algorithm will be judged on its ability to deliver data on schedule and the trade-offs associated with each method will be analyzed. It is now possible to introduce advance scheduling algorithms to the OPC data processing environment to meet the goals of on-time delivery of mask ready OPC data while maximizing efficiency and reducing cost.

  15. Eye movements and the span of the effective stimulus in visual search.

    PubMed

    Bertera, J H; Rayner, K

    2000-04-01

    The span of the effective stimulus during visual search through an unstructured alphanumeric array was investigated by using eye-contingent-display changes while the subjects searched for a target letter. In one condition, a window exposing the search array moved in synchrony with the subjects' eye movements, and the size of the window was varied. Performance reached asymptotic levels when the window was 5 degrees. In another condition, a foveal mask moved in synchrony with each eye movement, and the size of the mask was varied. The foveal mask conditions were much more detrimental to search behavior than the window conditions, indicating the importance of foveal vision during search. The size of the array also influenced performance, but performance reached asymptote for all array sizes tested at the same window size, and the effect of the foveal mask was the same for all array sizes. The results indicate that both acuity and difficulty of the search task influenced the span of the effective stimulus during visual search.

  16. The role of low-spatial frequencies in lexical decision and masked priming.

    PubMed

    Boden, C; Giaschi, D

    2009-04-01

    Spatial frequency filtering was used to test the hypotheses that low-spatial frequency information in printed text can: (1) lead to a rapid lexical decision or (2) facilitate word recognition. Adult proficient readers made lexical decisions in unprimed and masked repetition priming experiments with unfiltered, low-pass, high-pass and notch filtered letter strings. In the unprimed experiments, a filtered target was presented for 105 or 400 ms followed by a pattern mask. Sensitivity (d') was lowest for the low-pass filtered targets at both durations with a bias towards a 'non-word' response. Sensitivity was higher in the high-pass and notch filter conditions. In the priming experiments, a forward mask was followed by a filtered prime then an unfiltered target. Primed words, but not non-words, were identified faster than unprimed words in both the low-pass and high-pass filtered conditions. These results do not support a unique role for low-spatial frequency information in either facilitating or making rapid lexical decisions.

  17. In-line verification of linewidth uniformity for 0.18 and below: design rule reticles

    NASA Astrophysics Data System (ADS)

    Tan, TaiSheng; Kuo, Shen C.; Wu, Clare; Falah, Reuven; Hemar, Shirley; Sade, Amikam; Gottlib, Gidon

    2000-07-01

    Mask making process development and control is addressed using a reticle inspection tool equipped with the new revolutionized application called LBM-Linewidth Bias Monitoring. In order to use the LBM for mask-making process control, procedures and corresponding test plates are a developed, such that routine monitoring of the manufacturing process discloses process variation and machine variation. At the same time systematic variation are studied and either taken care of or taken into consideration to allow successful production line work. In this paper the contribution of the LBM for mask quality monitoring is studied with respect to dense layers, e.g. DRAM. Another aspect of this application - the detection of very small CD mis-uniformity areas is discussed.

  18. Thermal and Electrical Effects of Partial Shade in Monolithic Thin-Film Photovoltaic Modules: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Silverman, Timothy J.; Deceglie, Michael G.; Sun, Xingshu

    2015-09-02

    Photovoltaic cells can be damaged by reverse bias stress, which arises during service when a monolithically integrated thin-film module is partially shaded. We introduce a model for describing a module's internal thermal and electrical state, which cannot normally be measured. Using this model and experimental measurements, we present several results with relevance for reliability testing and module engineering: Modules with a small breakdown voltage experience less stress than those with a large breakdown voltage, with some exceptions for modules having light-enhanced reverse breakdown. Masks leaving a small part of the masked cells illuminated can lead to very high temperature andmore » current density compared to masks covering entire cells.« less

  19. Thermal and Electrical Effects of Partial Shade in Monolithic Thin-Film Photovoltaic Modules

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Silverman, Timothy J.; Deceglie, Michael G.; Sun, Xingshu

    2015-06-14

    Photovoltaic cells can be damaged by reverse bias stress, which arises during service when a monolithically integrated thin-film module is partially shaded. We introduce a model for describing a module's internal thermal and electrical state, which cannot normally be measured. Using this model and experimental measurements, we present several results with relevance for reliability testing and module engineering: Modules with a small breakdown voltage experience less stress than those with a large breakdown voltage, with some exceptions for modules having light-enhanced reverse breakdown. Masks leaving a small part of the masked cells illuminated can lead to very high temperature andmore » current density compared to masks covering entire cells.« less

  20. Increased variability of watershed areas in patients with high-grade carotid stenosis.

    PubMed

    Kaczmarz, Stephan; Griese, Vanessa; Preibisch, Christine; Kallmayer, Michael; Helle, Michael; Wustrow, Isabel; Petersen, Esben Thade; Eckstein, Hans-Henning; Zimmer, Claus; Sorg, Christian; Göttler, Jens

    2018-03-01

    Watershed areas (WSAs) of the brain are most susceptible to acute hypoperfusion due to their peripheral location between vascular territories. Additionally, chronic WSA-related vascular processes underlie cognitive decline especially in patients with cerebral hemodynamic compromise. Despite of high relevance for both clinical diagnostics and research, individual in vivo WSA definition is fairly limited to date. Thus, this study proposes a standardized segmentation approach to delineate individual WSAs by use of time-to-peak (TTP) maps and investigates spatial variability of individual WSAs. We defined individual watershed masks based on relative TTP increases in 30 healthy elderly persons and 28 patients with unilateral, high-grade carotid stenosis, being at risk for watershed-related hemodynamic impairment. Determined WSA location was confirmed by an arterial transit time atlas and individual super-selective arterial spin labeling. We compared spatial variability of WSA probability maps between groups and assessed TTP differences between hemispheres in individual and group-average watershed locations. Patients showed significantly higher spatial variability of WSAs than healthy controls. Perfusion on the side of the stenosis was delayed within individual watershed masks as compared to a watershed template derived from controls, being independent from the grade of the stenosis and collateralization status of the circle of Willis. Results demonstrate feasibility of individual WSA delineation by TTP maps in healthy elderly and carotid stenosis patients. Data indicate necessity of individual segmentation approaches especially in patients with hemodynamic compromise to detect critical regions of impaired hemodynamics.

  1. Effect of formulation variables on the physical properties and stability of Dead Sea mud masks.

    PubMed

    Shahin, Sawsan; Hamed, Saja; Alkhatib, Hatim S

    2015-01-01

    The physical stability of Dead Sea mud mask formulations under different conditions and their rheological properties were evaluated as a function of the type and level of thickeners, level of the humectant, incorporation of ethanol, and mode of mud treatment. Formulations were evaluated in terms of visual appearance, pH, moisture content, spreadability, extrudability, separation, rate of drying at 32 degrees C, and rheological properties. Prepared mud formulations and over-the-shelf products showed viscoplastic shear thinning behavior; satisfactory rheological behavior was observed with formulations containing a total concentration of thickeners less than 10% (w/w). Casson and Herschel-Bulkley models were found the most suitable to describe the rheological data of the prepared formulations. Thickener incorporation decreased phase separation and improved formulation stability. Bentonite incorporation in the mud prevented color changes during stability studies while glycerin improved spreadability. Addition of 5% (w/w) ethanol improved mud extrudability, slightly increased percent separation, accelerated drying at 32 degrees C, and decreased viscosity and yield stress values. Different mud treatment techniques did not cause a clear behavioral change in the final mud preparation. B10G and K5B5G were labeled as "best formulas" based on having satisfactory physical and aesthetic criteria investigated in this study, while other formulations failed in one or more of the tests we have performed.

  2. Anatomical masking of pressure footprints based on the Oxford Foot Model: validation and clinical relevance.

    PubMed

    Giacomozzi, Claudia; Stebbins, Julie A

    2017-03-01

    Plantar pressure analysis is widely used in the assessment of foot function. In order to assess regional loading, a mask is applied to the footprint to sub-divide it into regions of interest (ROIs). The most common masking method is based on geometric features of the footprint (GM). Footprint masking based on anatomical landmarks of the foot has been implemented more recently, and involves the integration of a 3D motion capture system, plantar pressure measurement device, and a multi-segment foot model. However, thorough validation of anatomical masking (AM) using pathological footprints has not yet been presented. In the present study, an AM method based on the Oxford Foot Model (OFM) was compared to an equivalent GM. Pressure footprints from 20 young healthy subjects (HG) and 20 patients with clubfoot (CF) were anatomically divided into 5 ROIs using a subset of the OFM markers. The same foot regions were also identified by using a standard GM method. Comparisons of intra-subject coefficient of variation (CV) showed that the OFM-based AM was at least as reliable as the GM for all investigated pressure parameters in all foot regions. Clinical relevance of AM was investigated by comparing footprints from HG and CF groups. Contact time, maximum force, force-time integral and contact area proved to be sensitive parameters that were able to distinguish HG and CF groups, using both AM and GM methods However, the AM method revealed statistically significant differences between groups in 75% of measured variables, compared to 62% using a standard GM method, indicating that the AM method is more sensitive for revealing differences between groups. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Perception of Water-Based Masking Sounds-Long-Term Experiment in an Open-Plan Office.

    PubMed

    Hongisto, Valtteri; Varjo, Johanna; Oliva, David; Haapakangas, Annu; Benway, Evan

    2017-01-01

    A certain level of masking sound is necessary to control the disturbance caused by speech sounds in open-plan offices. The sound is usually provided with evenly distributed loudspeakers. Pseudo-random noise is often used as a source of artificial sound masking (PRMS). A recent laboratory experiment suggested that water-based masking sound (WBMS) could be more favorable than PRMS. The purpose of our study was to determine how the employees perceived different WBMSs compared to PRMS. The experiment was conducted in an open-plan office of 77 employees who had been accustomed to work under PRMS (44 dB L Aeq ). The experiment consisted of five masking conditions: the original PRMS, four different WBMSs and return to the original PRMS. The exposure time of each condition was 3 weeks. The noise level was nearly equal between the conditions (43-45 dB L Aeq ) but the spectra and the nature of the sounds were very different. A questionnaire was completed at the end of each condition. Acoustic satisfaction was worse during the WBMSs than during the PRMS. The disturbance caused by three out of four WBMSs was larger than that of PRMS. Several attributes describing the sound quality itself were in favor of PRMS. Colleagues' speech sounds disturbed more during WBMSs. None of the WBMSs produced better subjective ratings than PRMS. Although the first WBMS was equal with the PRMS for several variables, the overall results cannot be seen to support the use of WBMSs in office workplaces. Because the experiment suffered from some methodological weaknesses, conclusions about the adequacy of WBMSs cannot yet be drawn.

  4. Perception of Water-Based Masking Sounds—Long-Term Experiment in an Open-Plan Office

    PubMed Central

    Hongisto, Valtteri; Varjo, Johanna; Oliva, David; Haapakangas, Annu; Benway, Evan

    2017-01-01

    A certain level of masking sound is necessary to control the disturbance caused by speech sounds in open-plan offices. The sound is usually provided with evenly distributed loudspeakers. Pseudo-random noise is often used as a source of artificial sound masking (PRMS). A recent laboratory experiment suggested that water-based masking sound (WBMS) could be more favorable than PRMS. The purpose of our study was to determine how the employees perceived different WBMSs compared to PRMS. The experiment was conducted in an open-plan office of 77 employees who had been accustomed to work under PRMS (44 dB LAeq). The experiment consisted of five masking conditions: the original PRMS, four different WBMSs and return to the original PRMS. The exposure time of each condition was 3 weeks. The noise level was nearly equal between the conditions (43–45 dB LAeq) but the spectra and the nature of the sounds were very different. A questionnaire was completed at the end of each condition. Acoustic satisfaction was worse during the WBMSs than during the PRMS. The disturbance caused by three out of four WBMSs was larger than that of PRMS. Several attributes describing the sound quality itself were in favor of PRMS. Colleagues' speech sounds disturbed more during WBMSs. None of the WBMSs produced better subjective ratings than PRMS. Although the first WBMS was equal with the PRMS for several variables, the overall results cannot be seen to support the use of WBMSs in office workplaces. Because the experiment suffered from some methodological weaknesses, conclusions about the adequacy of WBMSs cannot yet be drawn. PMID:28769834

  5. Confounding factors in determining causal soil moisture-precipitation feedback

    NASA Astrophysics Data System (ADS)

    Tuttle, Samuel E.; Salvucci, Guido D.

    2017-07-01

    Identification of causal links in the land-atmosphere system is important for construction and testing of land surface and general circulation models. However, the land and atmosphere are highly coupled and linked by a vast number of complex, interdependent processes. Statistical methods, such as Granger causality, can help to identify feedbacks from observational data, independent of the different parameterizations of physical processes and spatiotemporal resolution effects that influence feedbacks in models. However, statistical causal identification methods can easily be misapplied, leading to erroneous conclusions about feedback strength and sign. Here, we discuss three factors that must be accounted for in determination of causal soil moisture-precipitation feedback in observations and model output: seasonal and interannual variability, precipitation persistence, and endogeneity. The effect of neglecting these factors is demonstrated in simulated and observational data. The results show that long-timescale variability and precipitation persistence can have a substantial effect on detected soil moisture-precipitation feedback strength, while endogeneity has a smaller effect that is often masked by measurement error and thus is more likely to be an issue when analyzing model data or highly accurate observational data.

  6. Speech-on-speech masking with variable access to the linguistic content of the masker speech for native and non-native speakers of English

    PubMed Central

    Calandruccio, Lauren; Bradlow, Ann R.; Dhar, Sumitrajit

    2013-01-01

    Background Masking release for an English sentence-recognition task in the presence of foreign-accented English speech compared to native-accented English speech was reported in Calandruccio, Dhar and Bradlow (2010). The masking release appeared to increase as the masker intelligibility decreased. However, it could not be ruled out that spectral differences between the speech maskers were influencing the significant differences observed. Purpose The purpose of the current experiment was to minimize spectral differences between speech maskers to determine how various amounts of linguistic information within competing speech affect masking release. Research Design A mixed model design with within- (four two-talker speech maskers) and between-subject (listener group) factors was conducted. Speech maskers included native-accented English speech, and high-intelligibility, moderate-intelligibility and low-intelligibility Mandarin-accented English. Normalizing the long-term average speech spectra of the maskers to each other minimized spectral differences between the masker conditions. Study Sample Three listener groups were tested including monolingual English speakers with normal hearing, non-native speakers of English with normal hearing, and monolingual speakers of English with hearing loss. The non-native speakers of English were from various native-language backgrounds, not including Mandarin (or any other Chinese dialect). Listeners with hearing loss had symmetrical, mild sloping to moderate sensorineural hearing loss. Data Collection and Analysis Listeners were asked to repeat back sentences that were presented in the presence of four different two-talker speech maskers. Responses were scored based on the keywords within the sentences (100 keywords/masker condition). A mixed-model regression analysis was used to analyze the difference in performance scores between the masker conditions and the listener groups. Results Monolingual speakers of English with normal hearing benefited when the competing speech signal was foreign-accented compared to native-accented allowing for improved speech recognition. Various levels of intelligibility across the foreign-accented speech maskers did not influence results. Neither the non-native English listeners with normal hearing, nor the monolingual English speakers with hearing loss benefited from masking release when the masker was changed from native-accented to foreign-accented English. Conclusions Slight modifications between the target and the masker speech allowed monolingual speakers of English with normal hearing to improve their recognition of native-accented English even when the competing speech was highly intelligible. Further research is needed to determine which modifications within the competing speech signal caused the Mandarin-accented English to be less effective with respect to masking. Determining the influences within the competing speech that make it less effective as a masker, or determining why monolingual normal-hearing listeners can take advantage of these differences could help improve speech recognition for those with hearing loss in the future. PMID:25126683

  7. Effect of coping thickness and background type on the masking ability of a zirconia ceramic.

    PubMed

    Tabatabaian, Farhad; Taghizade, Fateme; Namdari, Mahshid

    2018-01-01

    The masking ability of zirconia ceramics as copings is unclear. The purpose of this in vitro study was to evaluate the effect of coping thickness and background type on the masking ability of a zirconia ceramic and to determine zirconia coping thickness cut offs for masking the backgrounds investigated. Thirty zirconia disks in 3 thickness groups of 0.4, 0.6, and 0.8 mm were placed on 9 backgrounds to measure CIELab color attributes using a spectrophotometer. The backgrounds included A1, A2, and A3.5 shade composite resin, A3 shade zirconia, nickel-chromium alloy, nonprecious gold-colored alloy, amalgam, black, and white. ΔE values were measured to determine color differences between the specimens on the A2 shade composite resin background and the same specimens on the other backgrounds. The color change (ΔE) values were compared with threshold values for acceptability (ΔE=5.5) and perceptibility (ΔE=2.6). Repeated measures ANOVA, the Bonferroni test, and 1-sample t tests were used to analyze data (α=.05). Mean ΔE values ranged between 1.44 and 7.88. The zirconia coping thickness, the background type, and their interaction affected the CIELab and ΔE values (P<.001). To achieve ideal masking, the minimum thickness of a zirconia coping should be 0.4 mm for A1 and A3.5 shade composite resin, A3 shade zirconia, and nonprecious gold-colored alloy, 0.6 mm for amalgam, and 0.8 mm for nickel-chromium alloy. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  8. Masking ability of a zirconia ceramic on composite resin substrate shades.

    PubMed

    Tabatabaian, Farhad; Shabani, Sima; Namdari, Mahshid; Sadeghpour, Koroush

    2017-01-01

    Masking ability of a restorative material plays an important role to cover discolored tooth structure; however, this ability has not yet been well understood in zirconia-based restorations. This study assessed the masking ability of a zirconia ceramic on composite resin substrates with different shades. Ten zirconia disc specimens, with 0.5 mm thickness and 10 mm diameter, were fabricated by a computer-aided design/computer-aided manufacturing system. A white substrate (control) and six composite resin substrates with different shades including A1, A2, A3, B2, C2, and D3 were prepared. The substrates had a cylindrical shape with 10 mm diameter and height. The specimens were placed onto the substrates for spectrophotometric evaluation. A spectrophotometer measured the L*, a*, and b* values for the specimens. ΔE values were calculated to determine the color differences between the groups and the control and then were compared with a perceptional threshold (ΔE = 2.6). Repeated measures ANOVA and Bonferroni tests were used for data analysis ( P < 0.05). The mean and standard deviation of ΔE values for A1, A2, A3, B2, C2, and D3 groups were 6.78 ± 1.59, 8.13 ± 1.66, 9.81 ± 2.64, 9.61 ± 1.38, 9.59 ± 2.63, and 8.13 ± 1.89, respectively. A significant difference was found among the groups in the ΔE values ( P = 0.006). The ΔE values were more than the perceptional threshold in all the groups ( P < 0.0001). Within the limitations of this study, it can be concluded that the tested zirconia ceramic could not thoroughly mask different shades of the composite resin substrates. Moreover, color masking of zirconia depends on the shade of substrate.

  9. Effects of passive and active movement on vibrotactile detection thresholds of the Pacinian channel and forward masking.

    PubMed

    Yıldız, Mustafa Z; Toker, İpek; Özkan, Fatma B; Güçlü, Burak

    2015-01-01

    We investigated the gating effect of passive and active movement on the vibrotactile detection thresholds of the Pacinian (P) psychophysical channel and forward masking. Previous work on gating mostly used electrocutaneous stimulation and did not allow focusing on tactile submodalities. Ten healthy adults participated in our study. Passive movement was achieved by swinging a platform, on which the participant's stimulated hand was attached, manually by a trained operator. The root-mean-square value of the movement speed was kept in a narrow range (slow: 10-20 cm/s, fast: 50-60 cm/s). Active movement was performed by the participant him-/herself using the same apparatus. The tactile stimuli consisted of 250-Hz sinusoidal mechanical vibrations, which were generated by a shaker mounted on the movement platform and applied to the middle fingertip. In the forward-masking experiments, a high-level masking stimulus preceded the test stimulus. Each movement condition was tested separately in a two-interval forced-choice detection task. Both passive and active movement caused a robust gating effect, that is, elevation of thresholds, in the fast speed range. Statistically significant change of thresholds was not found in slow movement conditions. Passive movement yielded higher thresholds than those measured during active movement, but this could not be confirmed statistically. On the other hand, the effect of forward masking was approximately constant as the movement condition varied. These results imply that gating depends on both peripheral and central factors in the P channel. Active movement may have some facilitatory role and produce less gating. Additionally, the results support the hypothesis regarding a critical speed for gating, which may be relevant for daily situations involving vibrations transmitted through grasped objects and for manual exploration.

  10. Preparing Juno for Environmental Testing

    NASA Image and Video Library

    2010-12-16

    NASA Juno spacecraft rests atop its rotation fixture awaiting transfer to a shipping crate prior to environmental testing; the large white square on the spacecraft right is largest of six microwave radiometer antennas, masked by protective covering.

  11. Periorbital Edema Secondary to Positive Airway Pressure Therapy

    PubMed Central

    Dandekar, Francesco; Camacho, Macario; Valerio, Jason

    2015-01-01

    Two patients developed bilateral, periorbital edema after initiating positive airway pressure (PAP) therapy with a full face mask. The periorbital edema was more pronounced in the morning and would dissipate throughout the day. This phenomenon seemed to be correlated with the direct pressure of the full face mask, which may have impaired lymphatic and venous drainage. To test this hypothesis, each patient was changed to a nasal pillow interface with subsequent improvement in the periorbital edema. PMID:25767727

  12. Periorbital edema secondary to positive airway pressure therapy.

    PubMed

    Dandekar, Francesco; Camacho, Macario; Valerio, Jason; Ruoff, Chad. M.

    2015-01-01

    Two patients developed bilateral, periorbital edema after initiating positive airway pressure (PAP) therapy with a full face mask. The periorbital edema was more pronounced in the morning and would dissipate throughout the day. This phenomenon seemed to be correlated with the direct pressure of the full face mask, which may have impaired lymphatic and venous drainage. To test this hypothesis, each patient was changed to a nasal pillow interface with subsequent improvement in the periorbital edema.

  13. Spatial release from masking improves sound pattern discrimination along a biologically relevant pulse-rate continuum in gray treefrogs

    PubMed Central

    Ward, Jessica L.; Buerkle, Nathan P.; Bee, Mark A.

    2013-01-01

    Frogs form large choruses during the mating season in which males produce loud advertisement calls to attract females and repel rival males. High background noise levels in these social aggregations can impair vocal perception. In humans, spatial release from masking contributes to our ability to understand speech in noisy social groups. Here, we tested the hypothesis that spatial separation between target signals and ‘chorus-shaped noise’ improves the ability of female gray treefrogs (Hyla chrysoscelis) to perform a behavioral discrimination task based on perceiving differences in the pulsatile structure of advertisement calls. We used two-stimulus choice tests to measure phonotaxis (approach toward sound) in response to calls differing in pulse rate along a biologically relevant continuum between conspecific (50 pulses s−1) and heterospecific (20 pulses s−1) calls. Signals were presented in quiet, in colocated noise, and in spatially separated noise. In quiet conditions, females exhibited robust preferences for calls with relatively faster pulse rates more typical of conspecific calls. Behavioral discrimination between calls differing in pulse rate was impaired in the presence of colocated noise but similar between quiet and spatially separated noise conditions. Our results indicate that spatial release from energetic masking facilitates a biologically important temporal discrimination task in frogs. We discuss these results in light of previous work on spatial release from masking in frogs and other animals. PMID:24055623

  14. 21 CFR 874.1120 - Electronic noise generator for audiometric testing.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Electronic noise generator for audiometric testing... noise generator for audiometric testing. (a) Identification. An electronic noise generator for.... It is intended to introduce a masking noise into the non-test ear during an audiometric evaluation...

  15. 21 CFR 874.1120 - Electronic noise generator for audiometric testing.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electronic noise generator for audiometric testing... noise generator for audiometric testing. (a) Identification. An electronic noise generator for.... It is intended to introduce a masking noise into the non-test ear during an audiometric evaluation...

  16. Reliability of breath by breath spirometry and relative flow-time indices for pulmonary function testing in horses.

    PubMed

    Burnheim, K; Hughes, K J; Evans, D L; Raidal, S L

    2016-11-28

    Respiratory problems are common in horses, and are often diagnosed as a cause of poor athletic performance. Reliable, accurate and sensitive spirometric tests of airway function in resting horses would assist with the diagnosis of limitations to breathing and facilitate investigations of the effects of various treatments on breathing capacity. The evaluation of respiratory function in horses is challenging and suitable procedures are not widely available to equine practitioners. The determination of relative flow or flow-time measures is used in paediatric patients where compliance may limit conventional pulmonary function techniques. The aim of the current study was to characterise absolute and relative indices of respiratory function in healthy horses during eupnoea (tidal breathing) and carbon dioxide (CO 2 )-induced hyperpnoea (rebreathing) using a modified mask pneumotrachographic technique well suited to equine practice, and to evaluate the reliability of this technique over three consecutive days. Coefficients of variation, intra-class correlations, mean differences and 95% confidence intervals across all days of testing were established for each parameter. The technique provided absolute measures of respiratory function (respiratory rate, tidal volume, peak inspiratory and expiratory flows, time to peak flow) consistent with previous studies and there was no significant effect of day on any measure of respiratory function. Variability of measurements was decreased during hyperpnea caused by rebreathing CO 2 , but a number of relative flow-time variables demonstrated good agreement during eupnoeic respiration. The technique was well tolerated by horses and study findings suggest the technique is suitable for evaluation of respiratory function in horses. The use of relative flow-time variables provided reproducible (consistent) results, suggesting the technique may be of use for repeated measures studies in horses during tidal breathing or rebreathing.

  17. Aerial image measurement technique for automated reticle defect disposition (ARDD) in wafer fabs

    NASA Astrophysics Data System (ADS)

    Zibold, Axel M.; Schmid, Rainer M.; Stegemann, B.; Scheruebl, Thomas; Harnisch, Wolfgang; Kobiyama, Yuji

    2004-08-01

    The Aerial Image Measurement System (AIMS)* for 193 nm lithography emulation has been brought into operation successfully worldwide. A second generation system comprising 193 nm AIMS capability, mini-environment and SMIF, the AIMS fab 193 plus is currently introduced into the market. By adjustment of numerical aperture (NA), illumination type and partial illumination coherence to match the conditions in 193 nm steppers or scanners, it can emulate the exposure tool for any type of reticles like binary, OPC and PSM down to the 65 nm node. The system allows a rapid prediction of wafer printability of defects or defect repairs, and critical features, like dense patterns or contacts on the masks without the need to perform expensive image qualification consisting of test wafer exposures followed by SEM measurements. Therefore, AIMS is a mask quality verification standard for high-end photo masks and established in mask shops worldwide. The progress on the AIMS technology described in this paper will highlight that besides mask shops there will be a very beneficial use of the AIMS in the wafer fab and we propose an Automated Reticle Defect Disposition (ARDD) process. With smaller nodes, where design rules are 65 nm or less, it is expected that smaller defects on reticles will occur in increasing numbers in the wafer fab. These smaller mask defects will matter more and more and become a serious yield limiting factor. With increasing mask prices and increasing number of defects and severability on reticles it will become cost beneficial to perform defect disposition on the reticles in wafer production. Currently ongoing studies demonstrate AIMS benefits for wafer fab applications. An outlook will be given for extension of 193 nm aerial imaging down to the 45 nm node based on emulation of immersion scanners.

  18. Experience-oriented tobacco-use prevention lecture using a COPD-simulation mask for junior high school students.

    PubMed

    Iizuka, Makito; Tomita, Kazuhide; Takeshima, Reiko

    2015-04-01

    We recently developed a mask that simulates the experience of having one of the major diseases caused by tobacco smoking: chronic obstructive pulmonary disease (COPD). Here we examined the effects of a tobacco-use prevention lecture accompanied by a pseudo-COPD experience created with this mask on adolescents' attitude toward smoking. Junior high school students (12-13 years old, n=165) in Japan were the subjects. The students attended a 30-min tobacco-use prevention lecture with slides and movie clips and engaged in a light exercise session wearing the COPD-simulation mask for 15min. Before and after the lecture, the students' attitudes toward smoking were evaluated by the Kano test for social nicotine dependence (KTSND). The total KTSND scores decreased significantly from 9.9±4.4 (mean±SD, n=149) to 7.5±5.3 (n=144). Ninety-eight students wore the COPD mask, and their modified Borg scale scores increased significantly from 0.7±1.0 to 3.2±2.1 after exercise (P<0.0001). To the questionnaire item "Do you think you understand the suffering of individuals with COPD?", 24 and 51 students answered "definitely yes" and "yes", whereas 16, 4 and 1 answered "Cannot say," "no" and "definitely no", respectively. The KTSND scores were significantly smaller in the former affirmative group compared to the latter negative group (P<0.05). Of the 98 students who wore the simulation mask, 83 reported being satisfied with this pseudo-COPD experience. The tobacco-use prevention lecture with the pseudo-COPD experience created by the simulation mask was effective and safe. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Taste masking of ondansetron hydrochloride by polymer carrier system and formulation of rapid-disintegrating tablets.

    PubMed

    Khan, Shagufta; Kataria, Prashant; Nakhat, Premchand; Yeole, Pramod

    2007-06-22

    The purpose of this research was to mask the intensely bitter taste of ondansetron HCl and to formulate a rapid-disintegrating tablet (RDT) of the taste-masked drug. Taste masking was done by complexing ondansetron HCl with aminoalkyl methacrylate copolymer (Eudragit EPO) in different ratios by the precipitation method. Drug-polymer complexes (DPCs) were tested for drug content, in vitro taste in simulated salivary fluid (SSF) of pH 6.2, and molecular property. Complex that did not release drug in SSF was considered taste-masked and selected for formulation RDTs. The complex with drug-polymer ratio of 8:2 did not show drug release in SSF; therefore, it was selected. The properties of tablets such as tensile strength, wetting time, water absorption ratio, in vitro disintegration time, and disintegration in the oral cavity were investigated to elucidate the wetting and disintegration characteristics of tablets. Polyplasdone XL-10 7% wt/wt gave the minimum disintegration time. Tablets of batch F4 containing spray-dried mannitol and microcrystalline cellulose in the ratio 1:1 and 7% wt/wt Polyplasdone XL-10 showed faster disintegration, within 12.5 seconds, than the marketed tablet (112 seconds). Good correlation between in vitro disintegration behavior and in the oral cavity was recognized. Taste evaluation of RDT in human volunteers revealed considerable taste masking with the degree of bitterness below threshold value (0.5) ultimately reaching to 0 within 15 minutes, whereas ondansetron HCl was rated intensely bitter with a score of 3 for 10 minutes. Tablets of batch F4 also revealed rapid drug release (t(90), 60 seconds) in SGF compared with marketed formulation (t(90), 240 seconds; P < .01). Thus, results conclusively demonstrated successful masking of taste and rapid disintegration of the formulated tablets in the oral cavity.

  20. Vibrotactile masking experiments reveal accelerated somatosensory processing in congenitally blind braille readers.

    PubMed

    Bhattacharjee, Arindam; Ye, Amanda J; Lisak, Joy A; Vargas, Maria G; Goldreich, Daniel

    2010-10-27

    Braille reading is a demanding task that requires the identification of rapidly varying tactile patterns. During proficient reading, neighboring characters impact the fingertip at ∼100 ms intervals, and adjacent raised dots within a character at 50 ms intervals. Because the brain requires time to interpret afferent sensorineural activity, among other reasons, tactile stimuli separated by such short temporal intervals pose a challenge to perception. How, then, do proficient Braille readers successfully interpret inputs arising from their fingertips at such rapid rates? We hypothesized that somatosensory perceptual consolidation occurs more rapidly in proficient Braille readers. If so, Braille readers should outperform sighted participants on masking tasks, which demand rapid perceptual processing, but would not necessarily outperform the sighted on tests of simple vibrotactile sensitivity. To investigate, we conducted two-interval forced-choice vibrotactile detection, amplitude discrimination, and masking tasks on the index fingertips of 89 sighted and 57 profoundly blind humans. Sighted and blind participants had similar unmasked detection (25 ms target tap) and amplitude discrimination (compared with 100 μm reference tap) thresholds, but congenitally blind Braille readers, the fastest readers among the blind participants, exhibited significantly less masking than the sighted (masker, 50 Hz, 50 μm; target-masker delays, ±50 and ±100 ms). Indeed, Braille reading speed correlated significantly and specifically with masking task performance, and in particular with the backward masking decay time constant. We conclude that vibrotactile sensitivity is unchanged but that perceptual processing is accelerated in congenitally blind Braille readers.

  1. Vibrotactile masking experiments reveal accelerated somatosensory processing in congenitally blind Braille readers

    PubMed Central

    Bhattacharjee, Arindam; Ye, Amanda J.; Lisak, Joy A.; Vargas, Maria G.; Goldreich, Daniel

    2010-01-01

    Braille reading is a demanding task that requires the identification of rapidly varying tactile patterns. During proficient reading, neighboring characters impact the fingertip at about 100-ms intervals, and adjacent raised dots within a character at 50-ms intervals. Because the brain requires time to interpret afferent sensorineural activity, among other reasons, tactile stimuli separated by such short temporal intervals pose a challenge to perception. How, then, do proficient Braille readers successfully interpret inputs arising from their fingertips at such rapid rates? We hypothesized that somatosensory perceptual consolidation occurs more rapidly in proficient Braille readers. If so, Braille readers should outperform sighted participants on masking tasks, which demand rapid perceptual processing, but would not necessarily outperform the sighted on tests of simple vibrotactile sensitivity. To investigate, we conducted two-interval forced-choice vibrotactile detection, amplitude discrimination, and masking tasks on the index fingertips of 89 sighted and 57 profoundly blind humans. Sighted and blind participants had similar unmasked detection (25-ms target tap) and amplitude discrimination (compared to 100-micron reference tap) thresholds, but congenitally blind Braille readers, the fastest readers among the blind participants, exhibited significantly less masking than the sighted (masker: 50-Hz, 50-micron; target-masker delays ±50 and ±100 ms). Indeed, Braille reading speed correlated significantly and specifically with masking task performance, and in particular with the backward masking decay time constant. We conclude that vibrotactile sensitivity is unchanged, but that perceptual processing is accelerated in congenitally blind Braille readers. PMID:20980584

  2. Normalizing CO2 in chronic hyperventilation by means of a novel breathing mask: a pilot study.

    PubMed

    Johansen, Troels; Jack, Sandy; Dahl, Ronald

    2013-10-01

    Chronic idiopathic hyperventilation (CIH) is a form of dysfunctional breathing that has proven hard to treat effectively. To perform a preliminary test of the hypothesis that by periodically inducing normocapnia over several weeks, it would be possible to raise the normal resting level of CO2 and achieve a reduction of symptoms. Six CIH patients were treated 2 h a day for 4 weeks with a novel breathing mask. The mask was used to induce normocapnia in these chronically hypocapnic patients. Capillary blood gases and acid/base parameters [capillary CO2 tension (PcapCO2 ), pH, and standard base excess (SBE)] were measured at baseline and once each week at least 3 h after mask use, as well as spirometric values, breath-holding tolerance and hyperventilation symptoms as per the Nijmegen Questionnaire (NQ). The mask treatment resulted in a significant increase of resting PcapCO2 (+0.45 kPa, P = 0.028), a moderate increase in SBE (+1.4 mEq/L, P = 0.035) and a small reduction in daily symptoms (-3.8 NQ units, P = 0.046). The effect was most pronounced in the first 2 weeks of treatment. By inducing normocapnia with the breathing mask 2 h a day for 4 weeks, the normal resting CO2 and acid/base levels in chronically hyperventilating patients were partially corrected, and symptoms were reduced. © 2013 John Wiley & Sons Ltd.

  3. Effect of Masking on Subjective Responses to Daily Disposable Contact Lenses.

    PubMed

    Keir, Nancy; Luensmann, Doerte; Woods, Craig A; Bergenske, Peter; Fahmy, Mary; Fonn, Desmond

    2016-08-01

    To explore the effect of masking on subjective responses when wearing daily disposable (DD) contact lenses. In an adaptation phase, habitual wearers of Manufacturer-A (MFA) (n = 43) and Manufacturer-B (MFB) (n = 53) wore MFA-brand 1 or MFB-brand 1 DDs, respectively, for 30 days, open-label. Subjects were then randomly assigned to one of two experiments. Each experiment included two, 3-day crossover phases. An enhanced version of MFA and MFB lenses (MFA-brand 2 and MFB-brand 2) were worn contralaterally to evaluate potential differences in masking result between manufacturers. Experiment 1: subjects were fully masked to lens and packaging (FM) then unmasked (UM). Experiment 2: subjects were FM then partially masked using an over-label (PM). Comfort ratings (0-100) were recorded for each lens daily and preference between lenses was recorded on day 3 for each crossover phase. The mean difference between 0-100 ratings or preference when FM or PM versus UM for the same lens was considered a measurement of the effect associated with masking. The purpose of the study was withheld from subjects to minimize bias. The effect associated with masking for habitual wearers of MFA and MFB lenses was less than 1 out of 100 (0 ± 2.5) in both experiments. Fifty-eight subjects (60%) expressed no preference when FM. This decreased to 29 (30%) when UM or PM (proportion test, p < 0.001). Approximately half the subjects had a change in lens preference when they were UM or PM, primarily in favor of their habitual lens manufacturer. Masking did not have a measurable impact on 0-100 ratings with the DD lenses used in this study but did have an impact on lens preference. Subjects were more likely to express a preference when they handled the lenses and were exposed to the lens packaging and, in some cases, able to read the lens brand and lens manufacturer.

  4. Microbial Contamination on Used Surgical Masks among Hospital Personnel and Microbial Air Quality in their Working Wards: A Hospital in Bangkok

    PubMed Central

    Luksamijarulkul, Pipat; Aiempradit, Natkitta; Vatanasomboon, Pisit

    2014-01-01

    Objective To assess the relationship of bacterial and fungal contamination on used surgical masks worn by the hospital personnel and microbial air quality in their working wards. Methods This is a cross-sectional study of 230 used surgical masks collected from 214 hospital personnel, and 215 indoor air samples collected from their working wards to culture for bacterial and fungal counts. This study was carried out at the hospital in Bangkok. Group or genus of isolated bacteria and fungi were preliminarily identified by Gram’s stain and lacto-phenol cotton blue. Data were analyzed using paired t-test and Pearson’s correlation coefficient at the significant level of p<0.050. Results Means and standard deviation of bacterial and fungal contamination on inside area of the used masks were 47 ± 56 and 15 ± 9 cfu/ml/piece, and on outside area were 166 ± 199 and 34 ± 18 cfu/ml/piece, respectively, p<0.001. The bacterial and fungal contamination on used masks from hospital personnel working in the male and female medical wards and out-patient department, as well as the bacterial and fungal counts of the indoor air sample collected from the same area were relatively higher than the other wards. The predominant isolated bacteria and fungi contaminated on inside and outside areas of the used masks and air samples were similar (Staphylococcus spp. and Aspergillus spp.; respectively). For its relationship, results found that bacterial and fungal counts in air samples showed significantly positive correlation with the bacterial contamination load on outside area of the used masks, r=0.16, p=0.018 and r=0.21, p=0.003, respectively. Conclusion High bacterial contamination on outside area of the used masks was demonstrated, and it showed a significant correlation with microbial air quality of working wards. PMID:25337311

  5. Microbial Contamination on Used Surgical Masks among Hospital Personnel and Microbial Air Quality in their Working Wards: A Hospital in Bangkok.

    PubMed

    Luksamijarulkul, Pipat; Aiempradit, Natkitta; Vatanasomboon, Pisit

    2014-09-01

    To assess the relationship of bacterial and fungal contamination on used surgical masks worn by the hospital personnel and microbial air quality in their working wards. This is a cross-sectional study of 230 used surgical masks collected from 214 hospital personnel, and 215 indoor air samples collected from their working wards to culture for bacterial and fungal counts. This study was carried out at the hospital in Bangkok. Group or genus of isolated bacteria and fungi were preliminarily identified by Gram's stain and lacto-phenol cotton blue. Data were analyzed using paired t-test and Pearson's correlation coefficient at the significant level of p<0.050. Means and standard deviation of bacterial and fungal contamination on inside area of the used masks were 47 ± 56 and 15 ± 9 cfu/ml/piece, and on outside area were 166 ± 199 and 34 ± 18 cfu/ml/piece, respectively, p<0.001. The bacterial and fungal contamination on used masks from hospital personnel working in the male and female medical wards and out-patient department, as well as the bacterial and fungal counts of the indoor air sample collected from the same area were relatively higher than the other wards. The predominant isolated bacteria and fungi contaminated on inside and outside areas of the used masks and air samples were similar (Staphylococcus spp. and Aspergillus spp.; respectively). For its relationship, results found that bacterial and fungal counts in air samples showed significantly positive correlation with the bacterial contamination load on outside area of the used masks, r=0.16, p=0.018 and r=0.21, p=0.003, respectively. High bacterial contamination on outside area of the used masks was demonstrated, and it showed a significant correlation with microbial air quality of working wards.

  6. The Supraglottic Effect of a Reduction in Expiratory Mask Pressure During Continuous Positive Airway Pressure

    PubMed Central

    Masdeu, Maria J.; Patel, Amit V.; Seelall, Vijay; Rapoport, David M.; Ayappa, Indu

    2012-01-01

    Study Objectives: Patients with obstructive sleep apnea may have difficulty exhaling against positive pressure, hence limiting their acceptance of continuous positive airway pressure (CPAP). C-Flex is designed to improve comfort by reducing pressure in the mask during expiration proportionally to expiratory airflow (3 settings correspond to increasing pressure changes). When patients use CPAP, nasal resistance determines how much higher supraglottic pressure is than mask pressure. We hypothesized that increased nasal resistance results in increased expiratory supraglottic pressure swings that could be mitigated by the effects of C-Flex on mask pressure. Design: Cohort study. Setting: Sleep center. Participants: Seventeen patients with obstructive sleep apnea/hypopnea syndrome and a mechanical model of the upper airway. Interventions: In patients on fixed CPAP, CPAP with different C-Flex levels was applied multiple times during the night. In the model, 2 different respiratory patterns and resistances were tested. Measurements and Results: Airflow, expiratory mask, and supraglottic pressures were measured on CPAP and on C-Flex. Swings in pressure during expiration were determined. On CPAP, higher nasal resistance produced greater expiratory pressure swings in the supraglottis in the patients and in the model, as expected. C-Flex 3 produced expiratory drops in mask pressure (range −0.03 to −2.49 cm H2O) but mitigated the expira-tory pressure rise in the supraglottis only during a sinusoidal respiratory pattern in the model. Conclusions: Expiratory changes in mask pressure induced by C-Flex did not uniformly transmit to the supraglottis in either patients with obstructive sleep apnea on CPAP or in a mechanical model of the upper airway with fixed resistance. Data suggest that the observed lack of expiratory drop in supraglottic pressure swings is related to dynamics of the C-Flex algorithm. Citation: Masdeu MJ; Patel AV; Seelall V; Rapoport DM; Ayappa I. The supraglottic effect of a reduction in expiratory mask pressure during continuous positive airway pressure. SLEEP 2012;35(2):263-272. PMID:22294817

  7. Framing of Feedback Impacts Student's Satisfaction, Self-Efficacy and Performance

    ERIC Educational Resources Information Center

    van de Ridder, J. M. Monica; Peters, Claudia M. M.; Stokking, Karel M.; de Ru, J. Alexander; ten Cate, Olle Th. J.

    2015-01-01

    Feedback is considered important to acquire clinical skills. Research evidence shows that feedback does not always improve learning and its effects may be small. In many studies, a variety of variables involved in feedback provision may mask either one of their effects. E.g., there is reason to believe that the way oral feedback is framed may…

  8. Longitudinal Analysis of Links between Bullying Victimization and Psychosomatic Maladjustment in Swedish Schoolchildren

    ERIC Educational Resources Information Center

    Hellfeldt, Karin; Gill, Peter Edward; Johansson, Björn

    2018-01-01

    Cross-sectional studies of bullying mask variability in categories of and persistence of bullying victimization. Longitudinal, individual-level data offers a greater insight into schoolchildren's psychosomatic maladjustment as a consequence of bullying. Swedish schoolchildren (n = 3,349), with unique identifiers, in 44 schools (4th-9th grade),…

  9. An Integrated Theory of Attention and Decision Making in Visual Signal Detection

    ERIC Educational Resources Information Center

    Smith, Philip L.; Ratcliff, Roger

    2009-01-01

    The simplest attentional task, detecting a cued stimulus in an otherwise empty visual field, produces complex patterns of performance. Attentional cues interact with backward masks and with spatial uncertainty, and there is a dissociation in the effects of these variables on accuracy and on response time. A computational theory of performance in…

  10. Loss of Visual Working Memory within Seconds: The Combined Use of Refreshable and Non-Refreshable Features

    ERIC Educational Resources Information Center

    Ricker, Timothy J.; Cowan, Nelson

    2010-01-01

    We reexamine the role of time in the loss of information from working memory, the limited information accessible for cognitive tasks. The controversial issue of whether working memory deteriorates over time was investigated using arrays of unconventional visual characters. Each array was followed by a postperceptual mask, a variable retention…

  11. Development and characterization of 21 polymorphic microsatellite markers for the barren-ground shrew, Sorex ugyunak (Mammalia: Sorcidae), through next-generation sequencing, and cross-species amplification in the masked shrew, S. cinereus

    USGS Publications Warehouse

    Sonsthagen, Sarah A.; Sage, G. Kevin; Fowler, Megan C.; Hope, Andrew G.; Cook, J.A.; Talbot, Sandra L.

    2013-01-01

    We used next generation shotgun sequencing to develop 21 novel microsatellite markers for the barren-ground shrew (Sorex ugyunak), which were polymorphic among individuals from northern Alaska. The loci displayed moderate allelic diversity (averaging 6.81 alleles per locus) and heterozygosity (averaging 70 %). Two loci deviated from Hardy–Weinberg equilibrium (HWE) due to heterozygote deficiency. While the population did not deviate from HWE overall, it showed significant linkage disequilibrium suggesting this population is not in mutation-drift equilibrium. Nineteen of 21 loci were polymorphic in masked shrews (S. cinereus) from interior Alaska and exhibited linkage equilibrium and HWE overall. All loci yielded sufficient variability for use in population studies.

  12. Four in vivo g-ratio-weighted imaging methods: Comparability and repeatability at the group level.

    PubMed

    Ellerbrock, Isabel; Mohammadi, Siawoosh

    2018-01-01

    A recent method, denoted in vivo g-ratio-weighted imaging, has related the microscopic g-ratio, only accessible by ex vivo histology, to noninvasive MRI markers for the fiber volume fraction (FVF) and myelin volume fraction (MVF). Different MRI markers have been proposed for g-ratio weighted imaging, leaving open the question which combination of imaging markers is optimal. To address this question, the repeatability and comparability of four g-ratio methods based on different combinations of, respectively, two imaging markers for FVF (tract-fiber density, TFD, and neurite orientation dispersion and density imaging, NODDI) and two imaging markers for MVF (magnetization transfer saturation rate, MT, and, from proton density maps, macromolecular tissue volume, MTV) were tested in a scan-rescan experiment in two groups. Moreover, it was tested how the repeatability and comparability were affected by two key processing steps, namely the masking of unreliable voxels (e.g., due to partial volume effects) at the group level and the calibration value used to link MRI markers to MVF (and FVF). Our data showed that repeatability and comparability depend largely on the marker for the FVF (NODDI outperformed TFD), and that they were improved by masking. Overall, the g-ratio method based on NODDI and MT showed the highest repeatability (90%) and lowest variability between groups (3.5%). Finally, our results indicate that the calibration procedure is crucial, for example, calibration to a lower g-ratio value (g = 0.6) than the commonly used one (g = 0.7) can change not only repeatability and comparability but also the reported dependency on the FVF imaging marker. Hum Brain Mapp 39:24-41, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  13. Are there specific benefits of amoxicillin plus metronidazole in Aggregatibacter actinomycetemcomitans-associated periodontitis? Double-masked, randomized clinical trial of efficacy and safety.

    PubMed

    Mombelli, Andrea; Cionca, Norbert; Almaghlouth, Adnan; Décaillet, Fabien; Courvoisier, Delphine S; Giannopoulou, Catherine

    2013-06-01

    It has been suggested that prescription of amoxicillin plus metronidazole in the context of periodontal therapy should be limited to patients with specific microbiologic profiles, especially those testing positive for Aggregatibacter actinomycetemcomitans. The main purpose of this analysis is to determine if patients positive for A. actinomycetemcomitans with moderate to advanced periodontitis benefit specifically from amoxicillin plus metronidazole given as an adjunct to full-mouth scaling and root planing. This is a double-masked, placebo-controlled, randomized longitudinal study including 41 participants who were positive for A. actinomycetemcomitans and 41 participants who were negative for A. actinomycetemcomitans. All 82 patients received full-mouth periodontal debridement performed within 48 hours. Patients then received either systemic antibiotics (375 mg amoxicillin and 500 mg metronidazole, three times daily) or placebo for 7 days. The primary outcome variable was persistence of sites with a probing depth (PD) >4 mm and bleeding on probing (BOP) at the 3-month reevaluation. Using multilevel logistic regression, the effect of the antibiotics was analyzed according to the following factors (interaction effect): A. actinomycetemcomitans-positive or -negative at baseline, sex, age, smoking, tooth being a molar, and interdental location. At reevaluation, participants in the test group had significantly fewer sites with a persisting PD >4 mm and BOP than control patients (P <0.01). Being A. actinomycetemcomitans-positive or -negative did not change the effect of the antibiotics. Patients benefited from the antibiotics irrespective of sex, age, or smoking status. Molars benefited significantly more from the antibiotics than non-molars (P for interaction effect = 0.03). Patients who were positive for A. actinomycetemcomitans had no specific benefit from amoxicillin plus metronidazole. Sites on molars benefited significantly more from the antibiotics than non-molar sites.

  14. Resistance to synthetic blood penetration of National Institute for Occupational Safety and Health-approved N95 filtering facepiece respirators and surgical N95 respirators

    PubMed Central

    Rengasamy, Samy; Sbarra, Deborah; Nwoko, Julian; Shaffer, Ronald

    2015-01-01

    Background Surgical N95 filtering facepiece respirators (FFRs), certified by the National Institute for Occupational Safety and Health (NIOSH) as a respirator and cleared by the Food and Drug Administration (FDA) as a surgical mask, are often used to protect from the inhalation of infectious aerosols and from splashes/sprays of body fluids in health care facilities. A shortage of respirators can be expected during a pandemic. The availability of surgical N95 FFRs can potentially be increased by incorporating FDA clearance requirements in the NIOSH respirator approval process. Methods Fluid resistance of NIOSH-approved N95 FFRs, and FDA-cleared surgical N95 FFRs and surgical masks was tested using the ASTM F1862 method at 450 and 635 cm/sec velocities and compared with the results from a third-party independent laboratory. Blood penetration through different layers of filter media of masks were also analyzed visually. Results Four N95 FFR models showed no test failures at both velocities. The penetration results obtained in the NIOSH laboratory were comparable to those from the third-party independent laboratory. The number of respirator samples failing the test increased with increasing test velocity. Conclusions The results indicate that several NIOSH-approved N95 FFR models would likely pass FD clearance requirements for resistance to synthetic blood penetration. PMID:26231551

  15. Volumetric capnography curves as lung function test to confirm bronchoconstriction after carbachol challenge in sedated dogs.

    PubMed

    Scheffzek, S; Mosing, M; Hirt, R; Iff, I; Moens, Y

    2012-12-01

    This study investigated volumetric capnography (VC) in detecting airway responsiveness following airway challenge using carbachol in seven sedated dogs via face mask. Nebulised saline was administered, followed by increasing concentrations of nebulised carbachol until airflow limitation occurred (EP). Dead space (DS) variables and shape indices of the VC curve were calculated automatically after entering arterial carbon dioxide tension. Airway DS, airway DS to tidal volume (VT) ratio and the intercept of slope 2 of the VC curve decreased significantly at EP by 10%, 13% and 16%, respectively, minute ventilation, VT and alveolar DS increased significantly at EP by 49%, 22% and 200%, respectively. We conclude that VC and derived indices may be used to verify a reaction to airway challenge caused by carbachol in sedated dogs. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. Impacts of Spatial Fidelity Violations in the Forward Signal Model on DOAS-based Greenhouse Gas Retrievals: a Preliminary Analysis for OCO-2 (and Other Missions)

    NASA Technical Reports Server (NTRS)

    Davis, Anthony B.; Frakenbert, Christian

    2012-01-01

    Success in three aspects of OCO-2 mission is threatened by unaccounted spa,al variability effects, all involving atmospheric scattering: 1. Low/moderately opaque clouds can escape the prescreening by mimicking a brighter surface. 2. Prescreening does not account for long-range radia,ve impact (adjacency effect) of nearby clouds. Need for extended cloud masking? 3. Oblique looks in target mode are highly exposed to surface adjacency and aerosol variability effects.We'll be covering all three bases!

  17. Testing statistical isotropy in cosmic microwave background polarization maps

    NASA Astrophysics Data System (ADS)

    Rath, Pranati K.; Samal, Pramoda Kumar; Panda, Srikanta; Mishra, Debesh D.; Aluri, Pavan K.

    2018-04-01

    We apply our symmetry based Power tensor technique to test conformity of PLANCK Polarization maps with statistical isotropy. On a wide range of angular scales (l = 40 - 150), our preliminary analysis detects many statistically anisotropic multipoles in foreground cleaned full sky PLANCK polarization maps viz., COMMANDER and NILC. We also study the effect of residual foregrounds that may still be present in the Galactic plane using both common UPB77 polarization mask, as well as the individual component separation method specific polarization masks. However, some of the statistically anisotropic modes still persist, albeit significantly in NILC map. We further probed the data for any coherent alignments across multipoles in several bins from the chosen multipole range.

  18. Face mask removal is safer than helmet removal for emergent airway access in American football.

    PubMed

    Swartz, Erik E; Mihalik, Jason P; Beltz, Nora M; Day, Molly A; Decoster, Laura C

    2014-06-01

    In cases of possible cervical spine injury, medical professionals must be prepared to achieve rapid airway access while concurrently restricting cervical spine motion. Face mask removal (FMR), rather than helmet removal (HR), is recommended to achieve this. However, no studies have been reported that compare FMR directly with HR. The purpose of this study was to compare motion, time, and perceived difficulty in two commonly used American football helmets between FMR and HR techniques, and when helmet air bladders were deflated before HR compared with inflated scenarios. The study incorporated a repeated measures design and was performed in a controlled laboratory setting. Participants included 22 certified athletic trainers (15 men and seven women; mean age, 33.9±10.5 years; mean experience, 11.4±10.0 years; mean height, 172±9.4 cm; mean mass, 76.7±14.9 kg). All participants were free from upper extremity or central nervous system pathology for 6 months and provided informed consent. Dependent variables included head excursion in degrees (computed by subtracting the minimum position from the maximum position) in each of the three planes (sagittal, frontal, transverse), time to complete the required task, and ratings of perceived exertion. To address our study purposes, we used two-by-two repeated-measures analysis of variance (removal technique×helmet type, helmet type×deflation status) for each dependent variable. Independent variables consisted of removal technique (FMR and HR), helmet type (Riddell Revolution IQ [RIQ] and VSR4), and helmet deflation status (deflated [D], inflated, [I]). After familiarization, participants conducted two successful trials for each of six conditions in random order (RIQ-FMR, VSR4-FMR, RIQ-HR-D, VSR4-HR-D, RIQ-HR-I, and VSR4-HR-I). Face masks, helmets, and shoulder pads were removed from a live model wearing a properly fitted helmet and shoulder pads. The participant and an investigator stabilized the model's head. A six-camera three-dimensional motion system and a three-point one-segment marker set were used to record motion of the head. Face mask removal resulted in less motion in all three planes, required less completion time, and was easier to perform than HR. The RIQ helmet resulted in less frontal plane motion and less time to task completion, and was easier to remove than VSR4 helmets. Inflated helmets-regardless of helmet type-required less removal time but did not result in greater cervical spine motion or difficulty. It is safer to remove the face mask in the prehospital setting for the potential spine-injured American football player than to remove the helmet, based on results from both a traditional and newer football helmet designs. Deflating the air bladder inside the helmet does not provide an advantage. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Characterization of Carbon Dioxide Washout Measurement Techniques in the Mark-III Space Suit

    NASA Technical Reports Server (NTRS)

    Meginnis, Ian M.; Norcross, Jason; Bekdash, Omar; Ploutz-Snyder, Robert

    2016-01-01

    A space suit must provide adequate carbon dioxide (CO2) washout inside the helmet to prevent symptoms of hypercapnia. In the past, an oronasal mask has been used to measure the inspired air of suited subjects to determine a space suit's CO2 washout capability. While sufficient for super-ambient pressure testing of space suits, the oronasal mask fails to meet several human factors and operational criterion needed for future sub-ambient pressure testing (e.g. compatibility with a Valsalva device). This paper describes the evaluation of a nasal cannula as a device for measuring inspired air within a space suit. Eight test subjects were tasked with walking on a treadmill or operating an arm ergometer to achieve target metabolic rates of 1000, 2000, and 3000 British thermal units per hour (BTU/hr), at flow rates of 2, 4, and 6 actual cubic feet per minute (ACFM). Each test configuration was conducted twice, with subjects instructed to breathe either through their nose only, or however they felt comfortable. Test data shows that the nasal cannula provides more statistically consistent data across test subjects than the oronasal mask used in previous tests. The data also shows that inhaling/exhaling through only the nose provides a lower sample variance than a normal breathing style. Nose-only breathing reports better CO2 washout due to several possible reasons, including a decreased respiratory rate, an increased tidal volume, and because nose-only breathing directs all of the exhaled CO2 down and away from the oronasal region. The test subjects in this study provided feedback that the nasal cannula is comfortable and can be used with the Valsalva device.

  20. Masking release for words in amplitude-modulated noise as a function of modulation rate and task

    PubMed Central

    Buss, Emily; Whittle, Lisa N.; Grose, John H.; Hall, Joseph W.

    2009-01-01

    For normal-hearing listeners, masked speech recognition can improve with the introduction of masker amplitude modulation. The present experiments tested the hypothesis that this masking release is due in part to an interaction between the temporal distribution of cues necessary to perform the task and the probability of those cues temporally coinciding with masker modulation minima. Stimuli were monosyllabic words masked by speech-shaped noise, and masker modulation was introduced via multiplication with a raised sinusoid of 2.5–40 Hz. Tasks included detection, three-alternative forced-choice identification, and open-set identification. Overall, there was more masking release associated with the closed than the open-set tasks. The best rate of modulation also differed as a function of task; whereas low modulation rates were associated with best performance for the detection and three-alternative identification tasks, performance improved with modulation rate in the open-set task. This task-by-rate interaction was also observed when amplitude-modulated speech was presented in a steady masker, and for low- and high-pass filtered speech presented in modulated noise. These results were interpreted as showing that the optimal rate of amplitude modulation depends on the temporal distribution of speech cues and the information required to perform a particular task. PMID:19603883

  1. Visualization of retinal vascular structure and perfusion with a nonconfocal adaptive optics scanning light ophthalmoscope

    PubMed Central

    Sulai, Yusufu N.; Scoles, Drew; Harvey, Zachary; Dubra, Alfredo

    2015-01-01

    Imaging of the retinal vascular structure and perfusion was explored by confocal illumination and nonconfocal detection in an adaptive optics scanning light ophthalmoscope (AOSLO), as an extension of the work by Chui et al. [Biomed. Opt. Express 3, 2537 (2012)]. Five different detection schemes were evaluated at multiple retinal locations: circular mask, annular mask, circular mask with filament, knife-edge, and split-detector. Given the superior image contrast in the reflectance and perfusion maps, the split-detection method was further tested using pupil apodization, polarized detection, and four different wavelengths. None of these variations provided noticeable contrast improvement. The noninvasive visualization of capillary flow and structure provided by AOSLO split-detection shows great promise for studying ocular and systemic conditions that affect the retinal vasculature. PMID:24690655

  2. The masking of beluga whale (Delphinapterus leucas) vocalizations by icebreaker noise

    NASA Astrophysics Data System (ADS)

    Erbe, Christine

    1998-11-01

    This thesis examines the masking effect of underwater noise on beluga whale communication. As ocean water is greatly opaque for light but well conducting for sound, marine mammals rely primarily on their hearing for orientation and communication. Man-made underwater noise has the potential of interfering with sounds used by marine mammals. Masking to the point of incomprehensibility can have fatal results-for the individual, but ultimately for the entire species. As part of our understanding of whether marine mammals can cope with human impact on nature, this thesis is the first to study the interference of real ocean noises with complex animal vocalizations. At the Vancouver Aquarium, a beluga whale was trained for acoustic experiments, during which masked hearing thresholds were measured. Focus lay on noise created by icebreaking ships in the Arctic. As experiments with trained animals are time and cost expensive, various techniques were examined for their ability to model the whale's response. These were human hearing tests, visual spectrogram discrimination, matched filtering, spectrogram cross-correlation, critical band cross-correlation, adaptive filtering and various types of artificial neural networks. The most efficient method with respect to similarity to the whale's data and speed, was a backpropagation neural net. Masked hearing thresholds would be of little use if they could not be related to accessible quantities in the wild. An ocean sound propagation model was applied to determine critical distances between a noise source, a calling whale and a listening whale. Colour diagrams, called maskograms, were invented to illustrate zones of masking in the wild. Results are that bubbler system noise with a source level of 194 dB re 1 μPa at 1 m has a maximum radius of masking of 15 km in a 3- dimensional ocean. Propeller noise with a source level of 203 dB re 1 μPa at 1 m has a maximum radius of masking of 22 km. A naturally occurring icecracking event with a source level of 147 dB re 1 μPa at 1 m only masks if the listening whale is within 8 m of the event. Therefore, in the wild, propeller cavitation noise masks furthest, followed by bubbler system noise, then icecracking noise.

  3. Single closed contact for 0.18-micron photolithography process

    NASA Astrophysics Data System (ADS)

    Cheung, Cristina; Phan, Khoi A.; Chiu, Robert J.

    2000-06-01

    With the rapid advances of deep submicron semiconductor technology, identifying defects is converted into a challenge for different modules in the fabrication of chips. Yield engineers often do bitmap on a memory circuit array (SRAM) to identify the failure bits. This is followed by a wafer stripback to look for visual defects at each deprocessed layer for feedback to the Fab. However, to identify the root cause of a problem, Fab engineers must be able to detect similar defects either on the product wafers in process or some short loop test wafers. In the photolithography process, we recognize that the detection of defects is becoming as important as satisfying the critical dimension (CD) of the device. For a multi-level metallization chemically mechanical polish backend process, it is very difficult to detect missing contacts or via at the masking steps due to metal grain roughness, film color variation and/or previous layer defects. Often, photolithography engineer must depend on Photo Cell Monitor (PCM) and short loop experiments for controlling baseline defects and improvement. In this paper, we discuss the findings on the Poly mask PCM and the Contact mask PCM. We present the comparison between the Poly mask and the Contact mask of the I-line Phase Shifted Via mask and DUV mask process for a 0.18 micron process technology. The correlation and the different type of defects between the Contact PCM and the Poly Mask are discussed. The Contact PCM was found to be more sensitive and correlated to contact failure at sort yield better. We also dedicate to study the root cause of a single closed contact hole in the Contact mask short loop experiment for a 0.18 micron process technology. A single closed contact defect was often caused by the developer process, such as bubbles in the line, resist residue left behind, and the rinse mechanism. We also found surfactant solution helps to improve the surface tension of the wafer for the developer process and this prevents/eliminates a single closed contact hole defects. The applications and effects of using different substrates like SiON, different thicknesses of Oxides, and Poly in the Contact Photo Mask is shown. Finally, some defect troubleshooting techniques and the root cause analysis are also discussed.

  4. Guidelines for Use of Personal Protective Equipment by Law Enforcement Personnel During a Terrorist Chemical Agent Incident. Revision 2

    DTIC Science & Technology

    2003-12-01

    mask increases the protection to the neck area that is often left exposed without one. Testing of protective ensembles, as discussed later in this...protective mask. Most often the area of the neck under the chin is left exposed . Since chemical agents are also effective through skin absorption it...suit. Less heat buildup due to air transfer. Can be exposed to water making it the preferred type of suit for operations in support of

  5. Effective masking levels for 500 and 2000 Hz bone conduction auditory steady state responses in infants and adults with normal hearing.

    PubMed

    Small, Susan A; Smyth, Aisling; Leon, Griselle

    2014-01-01

    Few studies have investigated effective masking levels (EMLs) needed to isolate the test ear for bone conduction assessments in infants. The objective of this study was to determine EMLs for 500 and 2000 Hz bone conduction auditory steady state responses (ASSRs) to amplitude (AM)/frequency-modulated (FM) stimuli for infants and adults with normal hearing. Maturational factors that contribute to infant-adult differences in EMLs will also be investigated. The present study and previously published 1000 and 4000 Hz EML data will be compared to investigate EML across four frequencies. These findings will provide a starting point for implementing clinical masking for infant bone conduction testing using physiological measures. Participants were 15 infants (7 to 35 weeks) and 15 adults (21 to 56 years) with normal hearing. Bone-conducted single ASSR stimuli (research MASTER) were 100% AM and 25% FM at 85 and 101 Hz for 500 and 2000 Hz carrier frequencies, respectively. They were presented at 25 and 35 dB HL for 500 Hz and at 35 and 45 dB HL for 2000 Hz for both infants and adults (approximately 10 and 20 dB SL at each frequency for infants). Air-conducted narrowband maskers were presented to both ears simultaneously. Real-ear to coupler differences were measured to account for differences in the sound pressure developed in infant and adult ear canals as a result of ear-canal size. Data analyses were conducted for mean EMLs across frequency (500 to 4000 Hz) and between age groups. Masked and unmasked ASSR amplitudes were compared for 500 and 2000 Hz. Both infants and adults required much more masking (25 to 33 dB) to eliminate responses at 500 compared with 2000 Hz. On average, infants required 16 dB more masking at 500 Hz and similar amounts of masking at 2000 Hz compared with adults. When adjusted for ear-canal size and bone conduction sensitivity, the pattern of results did not change. Across all four frequencies, infants showed a systematic decrease in mean EMLs with an increase in frequency; all pair-wise comparisons were significant except 2000 versus 4000 Hz. Adults showed smaller frequency-dependent changes in EML (only significantly greater for 500 versus 2000 Hz and 4000 Hz). When ear-canal size and bone conduction sensitivity were taken into account, only 500 Hz required more masking than other frequencies in infants; there were no significant frequency-dependent trends for adults, although the greater EMLs at 1000 versus 2000 Hz and 4000 Hz approached significance. Unmasked and masked amplitudes tended to be larger for 2000 Hz but not for 500 Hz when comparing infants with adults. EMLs appropriate for infants for bone conduction ASSRs elicited to AM/FM stimuli are considerably higher at 500 compared with 2000 Hz. Infants also need more masking at 500 Hz compared with adults but the same amount of masking at 2000 Hz. Comparisons across four frequencies reveal a systematic decrease in EML with an increase in frequency in infants, which is not apparent in adults. Recommended EMLs for AM/FM bone-conducted ASSR stimuli presented at 35 dB HL for 500, 1000, 2000, and 4000 Hz, respectively, are: (1) infants: 81, 68, 59, and 45 dB SPL, and (2) adults: 66, 63, 59, and 55 dB SPL.

  6. The color masking ability of a zirconia ceramic on the substrates with different values.

    PubMed

    Tabatabaian, Farhad; Javadi Sharif, Mahdiye; Massoumi, Farhood; Namdari, Mahshid

    2017-01-01

    Background. The color masking ability of a restoration plays a significant role in coveringa discolored substructure; however, this optical property of zirconia ceramics has not been clearly determined yet. The aim of this in vitro study was to evaluate the color masking ability of a zirconia ceramic on substrates with different values. Methods. Ten zirconia disk specimens,0.5 mm in thickness and 10 mm in diameter, were fabricated by a CAD/CAM system. Four substrates with different values were prepared, including: white (control), light grey, dark grey, and black. The disk specimens were placed over the substratesfor spectrophotometric measurements. A spectrophotometer measured the L * , a * , and b * color attributes of the specimens. Additionally, ΔE values were calculated to determine the color differences between each group and the control,and were then compared with the perceptional threshold of ΔE=2.6. Repeated-measures ANOVA, Bonferroni, and one-sample t-test were used to analyze data. All the tests were carried out at 0.05 level of significance. Results. The means and standard deviations of ΔE values for the three groups of light grey, dark grey and black were 9.94±2.11, 10.40±2.09, and 13.34±1.77 units, respectively.Significant differences were detected between the groups in the ΔE values (P<0.0001).The ΔE values in all the groups were more than the predetermined perceptional threshold(ΔE>2.6) (P<0.0001). Conclusion. Within the limitations of this study, it was concluded that the tested zirconia ceramic did not exhibit sufficient color masking ability to hide the grey and black substrates.

  7. Adhesive Systems as an Alternative Material for Color Masking of White Spot Lesions: Do They Work?

    PubMed

    de Lacerda, Ana Júlia Farias; da Silva Ávila, Daniele Mara; Borges, Alessandra Buhler; Pucci, Cesar Rogerio; Rocha Gomes Torres, Carlos

    2016-01-01

    To evaluate the color masking effect of infiltration treatment of artificial white spot lesions (AWSL) using a dedicated resin in comparison to different adhesive systems. Enamel/dentin specimens were obtained from bovine incisors and baseline color was assessed using a reflectance spectrophotometer, according to the CIE L*a*b* system. AWSL were produced using a buffered acid solution and a new color evaluation was performed. The specimens were divided into 8 groups: control: artificial saliva changed daily for 7 days; IC: infiltrating resin Icon; EC: EquiaCoat; FU: Futurabond U; SBU: Single Bond U; SBMP: Scotchbond MP; OB: OptibondFL; BF: Bioforty. After the treatments, the color was evaluated again and the values for the parameters ΔL (change in lightness), Δa (change in chroma), Δb (change in hue), and ΔE (general color difference) were calculated in relation to baseline. Data were analyzed by one-way ANOVA and Tukey's tests. After treatment, ANOVA showed significant differences for all parameters (p = 0.001). Tukey's test showed the greatest lightness reduction (ΔL) for the IC group, followed by EC, FU, and SBU. The SBMP, OB, and BF groups were similar to the control. For Δb values, all groups showed differences in relation to the control, with no differences between them. In relation to ΔE, all groups showed differences in relation to the control (ΔE = 5.24), with no significant differences between them. ΔE values after application of all resinous materials were lower than the threshold of 3.7, indicating effective color masking. The Icon infiltrant produced a greater lightness reduction of white lesions (ΔL). For general color difference (ΔE), all the resinous materials tested were able to color mask artificial AWSL.

  8. Binaural Hearing Ability With Bilateral Bone Conduction Stimulation in Subjects With Normal Hearing: Implications for Bone Conduction Hearing Aids.

    PubMed

    Zeitooni, Mehrnaz; Mäki-Torkko, Elina; Stenfelt, Stefan

    The purpose of this study is to evaluate binaural hearing ability in adults with normal hearing when bone conduction (BC) stimulation is bilaterally applied at the bone conduction hearing aid (BCHA) implant position as well as at the audiometric position on the mastoid. The results with BC stimulation are compared with bilateral air conduction (AC) stimulation through earphones. Binaural hearing ability is investigated with tests of spatial release from masking and binaural intelligibility level difference using sentence material, binaural masking level difference with tonal chirp stimulation, and precedence effect using noise stimulus. In all tests, results with bilateral BC stimulation at the BCHA position illustrate an ability to extract binaural cues similar to BC stimulation at the mastoid position. The binaural benefit is overall greater with AC stimulation than BC stimulation at both positions. The binaural benefit for BC stimulation at the mastoid and BCHA position is approximately half in terms of decibels compared with AC stimulation in the speech based tests (spatial release from masking and binaural intelligibility level difference). For binaural masking level difference, the binaural benefit for the two BC positions with chirp signal phase inversion is approximately twice the benefit with inverted phase of the noise. The precedence effect results with BC stimulation at the mastoid and BCHA position are similar for low frequency noise stimulation but differ with high-frequency noise stimulation. The results confirm that binaural hearing processing with bilateral BC stimulation at the mastoid position is also present at the BCHA implant position. This indicates the ability for binaural hearing in patients with good cochlear function when using bilateral BCHAs.

  9. Variations in backward masking with different masking stimuli: II. The effects of spatially quantised masks in the light of local contour interaction, interchannel inhibition, perceptual retouch, and substitution theories.

    PubMed

    Bachmann, Talis; Luiga, Iiris; Põder, Endel

    2005-01-01

    In part I we showed that with spatially non-overlapping targets and masks both local metacontrast-like interactions and attentional processes are involved in backward masking. In this second part we extend the strategy of varying the contents of masks to pattern masking where targets and masks overlap in space, in order to compare different masking theories. Images of human faces were backward-masked by three types of spatially quantised masks (the same faces as targets, faces different from targets, and Gaussian noise with power spectra typical for faces). Configural characteristics, rather than the spectral content of the mask, predicted the extent of masking at relatively long stimulus onset asynchronies (SOAs). This poses difficulties for the theory of transient-on-sustained inhibition as the principal mechanism of masking and also for local contour interaction being a decisive factor in pattern masking. The scale of quantisation had no effect on the masking capacity of noise masks and a strong effect on the capacity of different-face masks. Also, the decrease of configural masking with an increase in the coarseness of the quantisation of the mask highlights ambiguities inherent in the re-entrance-based substitution theory of masking. Different masking theories cannot solve the problems of masking separately. They should be combined in order to create a complex, yet comprehensible mode of interaction for the different mechanisms involved in visual backward masking.

  10. Sham radiation in clinical trials assessing radiotherapy for exudative age-related macular degeneration.

    PubMed

    Marcus, D M; Camp, M W; Sheils, W C; McIntosh, S B; Leibach, D B; Johnson, M H; Samy, C N

    1999-01-01

    To evaluate the effectiveness of sham radiation treatments in masking patients to their randomization group in the Radiation of Age-Related Macular Degeneration (ROARMD) Study. Patients with choroidal neovascularization complicating age-related macular degeneration were randomized to a treatment (RAD) group that received external beam irradiation (seven treatment sessions) or to a control (SHAM) group that received sham radiation (one sham treatment session). During a telephone survey, 62 of 73 randomized patients responded to the following questions: Do you think you received radiation? Why do you feel that way? Did the vision in your study eye worsen after enrollment? Eighty-one percent of the RAD group and 59% of the SHAM group thought that they had received radiation. In patients who thought that their vision had stabilized or improved, 82% thought that they had received radiation. In patients who thought that their vision was worse, only 39% thought that they had received radiation. In 54% of patients, subjective perception of vision influenced their guess as to whether they received radiation. Subjective patient perception of visual outcome was the most influential variable for masking. Variation between radiation treatment and sham session techniques, such as equipment used and duration of treatments, played a lesser role in the masking of patients. Seven treatment days correlated with a higher number of patients who thought that they had received radiation. Although our procedures do not strictly mask the two groups, one sham radiation session was effective in keeping patients guessing their randomization group.

  11. Scatterometry measurement of nested lines, dual space, and rectangular contact CD on phase-shift masks

    NASA Astrophysics Data System (ADS)

    Lee, Kyung M.; Yedur, Sanjay; Henrichs, Sven; Tavassoli, Malahat; Baik, Kiho

    2007-03-01

    Evaluation of lithography process or stepper involves very large quantity of CD measurements and measurement time. In this paper, we report on a application of Scatterometry based metrology for evaluation of binary photomask lithography. Measurements were made on mask level with ODP scatterometer then on wafer with CD-SEM. 4 to 1 scaling from mask to wafer means 60nm line on wafer translates to 240nm on mask, easily measurable on ODP. Calculation of scatterometer profile information was performed by a in-situ library-based analysis (5sec/site). We characterized the CD uniformity, linearity, and metal film thickness uniformity. Results show that linearity measured from fixed-pitch, varying line/space ratio targets show good correlation to top-down CD-SEM with R2 of more than 0.99. ODP-SEM correlation results for variable pitch shows that careful examination of scatterometer profile results in order to obtain better correlation to CD SEM, since both tools react differently to the target profile variation. ODP results show that global CD distribution is clearly measurable with less outliers compared to CD SEM data. This is thought to be due to 'averaging' effect of scatterometer. The data show that Scatterometry provides a nondestructive and faster mean of characterizing lithography stepper performanceprofiles. APSM 1st level (before Cr removal) 'dual-space' CDs and EPSM rectangular contacts were also measured with and results demonstrates that Scatterometer is capable of measuring these targets with reasonable correlation to SEM.

  12. Monitoring changes in Bemisia tabaci (Hemiptera: Aleyrodidae) susceptibility to neonicotinoid insecticides in Arizona and California.

    PubMed

    Castle, S J; Prabhaker, N

    2013-06-01

    Bemisia tabaci (Gennadius) biotype B is a highly prolific and polyphagous whitefly that established in much of North America during the 1980s. Neonicotinoid insecticides have been fundamental in regaining control over outbreak populations of B. tabaci, but resistance threatens their sustainability. Susceptibility of B. tabaci in the southwestern United States to four neonicotinoid insecticides varied considerably across populations within each year over a 3 yr period. Using a variability ratio of highest LC50 to lowest LC50 in field-collected whitefly adults from Arizona and California, the ranges of LC50(s) across all tests within compounds were highest to imidacloprid and lowest to thiamethoxam. Patterns of susceptibility were similar among all four neonicotinoid insecticides, but the greater variability in responses to imidacloprid and significantly higher LC50(s) attained indicated higher resistance levels to imidacloprid in all field populations. Further evidence of differential toxicities of neonicotinoids was observed in multiple tests of dinotefuran against imidacloprid-resistant lab strains that yielded significant differences in the LC50(s) of dinotefuran and imidacloprid in simultaneous bioassays. To test the possibility that resistance expression in field-collected insects was sometimes masked by stressful conditions, field strains cultured in a greenhouse without insecticide exposure produced significantly higher LC50(s) to all neonicotinoids compared with LC50(s) attained directly from the field. In harsh climates such as the American southwest, resistance expression in field-collected test insects may be strongly influenced by environmental stresses such as high temperatures, overcrowding, and declining host plant quality.

  13. MRI Analysis of White Matter Myelin Water Content in Multiple Sclerosis: A Novel Approach Applied to Finding Correlates of Cortical Thinning

    PubMed Central

    Dayan, Michael; Hurtado Rúa, Sandra M.; Monohan, Elizabeth; Fujimoto, Kyoko; Pandya, Sneha; LoCastro, Eve M.; Vartanian, Tim; Nguyen, Thanh D.; Raj, Ashish; Gauthier, Susan A.

    2017-01-01

    A novel lesion-mask free method based on a gamma mixture model was applied to myelin water fraction (MWF) maps to estimate the association between cortical thickness and myelin content, and how it differs between relapsing-remitting (RRMS) and secondary-progressive multiple sclerosis (SPMS) groups (135 and 23 patients, respectively). It was compared to an approach based on lesion masks. The gamma mixture distribution of whole brain, white matter (WM) MWF was characterized with three variables: the mode (most frequent value) m1 of the gamma component shown to relate to lesion, the mode m2 of the component shown to be associated with normal appearing (NA) WM, and the mixing ratio (λ) between the two distributions. The lesion-mask approach relied on the mean MWF within lesion and within NAWM. A multivariate regression analysis was carried out to find the best predictors of cortical thickness for each group and for each approach. The gamma-mixture method was shown to outperform the lesion-mask approach in terms of adjusted R2, both for the RRMS and SPMS groups. The predictors of the final gamma-mixture models were found to be m1 (β = 1.56, p < 0.005), λ (β = −0.30, p < 0.0005) and age (β = −0.0031, p < 0.005) for the RRMS group (adjusted R2 = 0.16), and m2 (β = 4.72, p < 0.0005) for the SPMS group (adjusted R2 = 0.45). Further, a DICE coefficient analysis demonstrated that the lesion mask had more overlap to an ROI associated with m1, than to an ROI associated with m2 (p < 0.00001), and vice versa for the NAWM mask (p < 0.00001). These results suggest that during the relapsing phase, focal WM damage is associated with cortical thinning, yet in SPMS patients, global WM deterioration has a much stronger influence on secondary degeneration. Through these findings, we demonstrate the potential contribution of myelin loss on neuronal degeneration at different disease stages and the usefulness of our statistical reduction technique which is not affected by the typical bias associated with approaches based on lesion masks. PMID:28603479

  14. Equine behaviour and heart rate in temperament tests with or without rider or handler.

    PubMed

    König von Borstel, U; Euent, S; Graf, P; König, S; Gauly, M

    2011-09-01

    The aim of the present study was to compare horses' heart rate (HR), heart rate variability (RMSSD, pNN50) and behaviour in the same temperament test when being ridden, led, and released free. Behavioural measurements included scores and linear measurements for reactivity (R), activity (A), time to calm down (T) and emotionality (E), recorded during the approach (1) and/or during confrontation with the stimulus (2). Sixty-five horses were each confronted 3 times (1 ridden, 1 led, 1 free running in balanced order) with 3 novel and/or sudden stimuli. Mixed model analysis indicated that leading resulted in the lowest (P<0.05 throughout) reactions as measured by A1, A2, E1, E2, R2, and pNN50 while riding produced the strongest (A1, T2, HR, RMSSD, pNN50) or medium (E1, E2, R2) reactions. Free running resulted either in the strongest (A2, E1, E2, R2) or in the lowest (A1, T2, HR, RMSSD, pNN50) reactions. The repeatability across tests for HR (0.57), but not for RMSSD (0.23) or pNN50 (0.25) was higher than for any behavioural measurement: the latter ranged from values below 0.10 (A1, A2, T2) to values between 0.30 and 0.45 (E1, E2, R2). Overall, the results show that a rider or handler influences, but not completely masks, the horses' intrinsic behaviour in a temperament test, and this influence appeared to be stronger on behavioural variables and heart rate variability than on the horses' heart rates. Taking both practical considerations and repeatabilities into account, reactivity appears to be the most valuable parameter. Emotionality and heart rate can also yield valid results reflecting additional dimensions of temperament although their practical relevance may be less obvious. If a combination of observed variables is chosen with care, a valid assessment of a horse's temperament may be possible in all types of tests. However, in practice, tests that resemble the practical circumstances most closely, i.e. testing riding horses under a rider, should be chosen. Copyright © 2011 Elsevier B.V. All rights reserved.

  15. Masking release with changing fundamental frequency: Electric acoustic stimulation resembles normal hearing subjects.

    PubMed

    Auinger, Alice Barbara; Riss, Dominik; Liepins, Rudolfs; Rader, Tobias; Keck, Tilman; Keintzel, Thomas; Kaider, Alexandra; Baumgartner, Wolf-Dieter; Gstoettner, Wolfgang; Arnoldner, Christoph

    2017-07-01

    It has been shown that patients with electric acoustic stimulation (EAS) perform better in noisy environments than patients with a cochlear implant (CI). One reason for this could be the preserved access to acoustic low-frequency cues including the fundamental frequency (F0). Therefore, our primary aim was to investigate whether users of EAS experience a release from masking with increasing F0 difference between target talker and masking talker. The study comprised 29 patients and consisted of three groups of subjects: EAS users, CI users and normal-hearing listeners (NH). All CI and EAS users were implanted with a MED-EL cochlear implant and had at least 12 months of experience with the implant. Speech perception was assessed with the Oldenburg sentence test (OlSa) using one sentence from the test corpus as speech masker. The F0 in this masking sentence was shifted upwards by 4, 8, or 12 semitones. For each of these masker conditions the speech reception threshold (SRT) was assessed by adaptively varying the masker level while presenting the target sentences at a fixed level. A statistically significant improvement in speech perception was found for increasing difference in F0 between target sentence and masker sentence in EAS users (p = 0.038) and in NH listeners (p = 0.003). In CI users (classic CI or EAS users with electrical stimulation only) speech perception was independent from differences in F0 between target and masker. A release from masking with increasing difference in F0 between target and masking speech was only observed in listeners and configurations in which the low-frequency region was presented acoustically. Thus, the speech information contained in the low frequencies seems to be crucial for allowing listeners to separate multiple sources. By combining acoustic and electric information, EAS users even manage tasks as complicated as segregating the audio streams from multiple talkers. Preserving the natural code, like fine-structure cues in the low-frequency region, seems to be crucial to provide CI users with the best benefit. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Change in the magnitude and mechanisms of global temperature variability with warming

    PubMed Central

    Brown, Patrick T.; Ming, Yi; Li, Wenhong; Hill, Spencer A.

    2017-01-01

    Natural unforced variability in global mean surface air temperature (GMST) can mask or exaggerate human-caused global warming, and thus a complete understanding of this variability is highly desirable. Significant progress has been made in elucidating the magnitude and physical origins of present-day unforced GMST variability, but it has remained unclear how such variability may change as the climate warms. Here we present modeling evidence that indicates that the magnitude of low-frequency GMST variability is likely to decline in a warmer climate and that its generating mechanisms may be fundamentally altered. In particular, a warmer climate results in lower albedo at high latitudes, which yields a weaker albedo feedback on unforced GMST variability. These results imply that unforced GMST variability is dependent on the background climatological conditions, and thus climate model control simulations run under perpetual preindustrial conditions may have only limited relevance for understanding the unforced GMST variability of the future. PMID:29391875

  17. Difficulty identifying feelings and automatic activation in the fusiform gyrus in response to facial emotion.

    PubMed

    Eichmann, Mischa; Kugel, Harald; Suslow, Thomas

    2008-12-01

    Difficulties in identifying and differentiating one's emotions are a central characteristic of alexithymia. In the present study, automatic activation of the fusiform gyrus to facial emotion was investigated as a function of alexithymia as assessed by the 20-item Toronto Alexithymia Scale. During 3 Tesla fMRI scanning, pictures of faces bearing sad, happy, and neutral expressions masked by neutral faces were presented to 22 healthy adults who also responded to the Toronto Alexithymia Scale. The fusiform gyrus was selected as the region of interest, and voxel values of this region were extracted, summarized as means, and tested among the different conditions (sad, happy, and neutral faces). Masked sad facial emotions were associated with greater bilateral activation of the fusiform gyrus than masked neutral faces. The subscale, Difficulty Identifying Feelings, was negatively correlated with the neural response of the fusiform gyrus to masked sad faces. The correlation results suggest that automatic hyporesponsiveness of the fusiform gyrus to negative emotion stimuli may reflect problems in recognizing one's emotions in everyday life.

  18. Compression of regions in the global advanced very high resolution radiometer 1-km data set

    NASA Technical Reports Server (NTRS)

    Kess, Barbara L.; Steinwand, Daniel R.; Reichenbach, Stephen E.

    1994-01-01

    The global advanced very high resolution radiometer (AVHRR) 1-km data set is a 10-band image produced at USGS' EROS Data Center for the study of the world's land surfaces. The image contains masked regions for non-land areas which are identical in each band but vary between data sets. They comprise over 75 percent of this 9.7 gigabyte image. The mask is compressed once and stored separately from the land data which is compressed for each of the 10 bands. The mask is stored in a hierarchical format for multi-resolution decompression of geographic subwindows of the image. The land for each band is compressed by modifying a method that ignores fill values. This multi-spectral region compression efficiently compresses the region data and precludes fill values from interfering with land compression statistics. Results show that the masked regions in a one-byte test image (6.5 Gigabytes) compress to 0.2 percent of the 557,756,146 bytes they occupy in the original image, resulting in a compression ratio of 89.9 percent for the entire image.

  19. The absence of an Atlantic imprint on the multidecadal variability of wintertime European temperature.

    PubMed

    Yamamoto, Ayako; Palter, Jaime B

    2016-03-15

    Northern Hemisphere climate responds sensitively to multidecadal variability in North Atlantic sea surface temperature (SST). It is therefore surprising that an imprint of such variability is conspicuously absent in wintertime western European temperature, despite that Europe's climate is strongly influenced by its neighbouring ocean, where multidecadal variability in basin-average SST persists in all seasons. Here we trace the cause of this missing imprint to a dynamic anomaly of the atmospheric circulation that masks its thermodynamic response to SST anomalies. Specifically, differences in the pathways Lagrangian particles take to Europe during anomalous SST winters suppress the expected fluctuations in air-sea heat exchange accumulated along those trajectories. Because decadal variability in North Atlantic-average SST may be driven partly by the Atlantic Meridional Overturning Circulation (AMOC), the atmosphere's dynamical adjustment to this mode of variability may have important implications for the European wintertime temperature response to a projected twenty-first century AMOC decline.

  20. LASR-Guided Variability Subtraction: The Linear Algorithm for Significance Reduction of Stellar Seismic Activity

    NASA Astrophysics Data System (ADS)

    Horvath, Sarah; Myers, Sam; Ahlers, Johnathon; Barnes, Jason W.

    2017-10-01

    Stellar seismic activity produces variations in brightness that introduce oscillations into transit light curves, which can create challenges for traditional fitting models. These oscillations disrupt baseline stellar flux values and potentially mask transits. We develop a model that removes these oscillations from transit light curves by minimizing the significance of each oscillation in frequency space. By removing stellar variability, we prepare each light curve for traditional fitting techniques. We apply our model to $\\delta$-Scuti KOI-976 and demonstrate that our variability subtraction routine successfully allows for measuring bulk system characteristics using traditional light curve fitting. These results open a new window for characterizing bulk system parameters of planets orbiting seismically active stars.

Top