SEDIMENT TOXICITY ASSESSMENT: COMPARISON OF STANDARD AND NEW TESTING DESIGNS
Standard methods of sediment toxicity testing are fairly well accepted; however, as with all else, evolution of these methods is inevitable. We compared a standard ASTM 10-day amphipod toxicity testing method with smaller, 48- and 96-h test methods using very toxic and reference ...
Drinking water test methods in crisis-afflicted areas: comparison of methods under field conditions.
Merle, Roswitha; Bleul, Ingo; Schulenburg, Jörg; Kreienbrock, Lothar; Klein, Günter
2011-11-01
To simplify the testing of drinking water in crisis-afflicted areas (as in Kosovo in 2007), rapid test methods were compared with the standard test. For Escherichia coli and coliform pathogens, rapid tests were made available: Colilert(®)-18, P/A test with 4-methylumbelliferyl-β-D-glucoronid, and m-Endo Broth. Biochemical differentiation was carried out by Enterotube™ II. Enterococci were determined following the standard ISO test and by means of Enterolert™. Four hundred ninety-nine water samples were tested for E. coli and coliforms using four methods. Following the standard method, 20.8% (n=104) of the samples contained E. coli, whereas the rapid tests detected between 19.6% (m-Endo Broth, 92.0% concordance) and 20.0% (concordance: 93.6% Colilert-18 and 94.8% P/A-test) positive samples. Regarding coliforms, the percentage of concordant results ranged from 98.4% (P/A-test) to 99.0% (Colilert-18). Colilert-18 and m-Endo Broth detected even more positive samples than the standard method did. Enterococci were detected in 93 of 573 samples by the standard method, but in 92 samples by Enterolert (concordance: 99.5%). Considering the high-quality equipment and time requirements of the standard method, the use of rapid tests in crisis-afflicted areas is sufficiently reliable.
40 CFR 98.7 - What standardized methods are incorporated by reference into this part?
Code of Federal Regulations, 2012 CFR
2012-07-01
....astm.org. (1) ASTM C25-06 Standard Test Method for Chemical Analysis of Limestone, Quicklime, and....194(c), and § 98.334(b). (2) ASTM C114-09 Standard Test Methods for Chemical Analysis of Hydraulic... approved for § 98.6. (4) ASTM D240-02 (Reapproved 2007) Standard Test Method for Heat of Combustion of...
40 CFR 98.7 - What standardized methods are incorporated by reference into this part?
Code of Federal Regulations, 2013 CFR
2013-07-01
....astm.org. (1) ASTM C25-06 Standard Test Method for Chemical Analysis of Limestone, Quicklime, and....194(c), and § 98.334(b). (2) ASTM C114-09 Standard Test Methods for Chemical Analysis of Hydraulic... approved for § 98.6. (4) ASTM D240-02 (Reapproved 2007) Standard Test Method for Heat of Combustion of...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-12
... Sulfur in Petroleum Products (General Bomb Method); ASTM D2622-98, Standard Test Method for Sulfur in...; ASTM D240-00, Standard Test Method for Heat of Combustion of Liquid Hydrocarbon Fuels by Bomb... Liquid Hydrocarbon Fuels by Bomb Calorimeter, ASTM D4809-00, Standard Test Method for Heat of Combustion...
49 CFR 383.133 - Testing methods.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 5 2010-10-01 2010-10-01 false Testing methods. 383.133 Section 383.133... STANDARDS; REQUIREMENTS AND PENALTIES Tests § 383.133 Testing methods. (a) All tests shall be constructed in... must be at least as stringent as the Federal standards. (c) States shall determine specific methods for...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Products (General Bomb Method) § 761.71(b)(2)(vi) ASTM D 240-87 Standard Test Method for Heat of Combustion of Liquid Hydrocarbon Fuel by Bomb Calorimeter § 761.71(b)(2)(vi) ASTM D 482-87 Standard Test Method... in New and Used Petroleum Products (Bomb Method) § 761.71(b)(2)(vi) ASTM D 923-86 Standard Test...
16 CFR 1610.3 - Summary of test method.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Summary of test method. 1610.3 Section 1610.3 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FLAMMABLE FABRICS ACT REGULATIONS STANDARD FOR THE FLAMMABILITY OF CLOTHING TEXTILES The Standard § 1610.3 Summary of test method. The Standard...
29 CFR Appendix A to Subpart Q of... - References to subpart Q of Part 1926
Code of Federal Regulations, 2010 CFR
2010-07-01
... (ASTM C39-86). • Standard Test Method for Making and Curing Concrete Test Specimens in the Field (ASTM C31-85). • Standard Test Method for Penetration Resistance of Hardened Concrete (ASTM C803-82... (ASTM C873-85). • Standard Method for Developing Early Age Compressive Test Values and Projecting Later...
40 CFR 98.7 - What standardized methods are incorporated by reference into this part?
Code of Federal Regulations, 2014 CFR
2014-07-01
...-B2959, (800) 262-1373, http://www.astm.org. (1) ASTM C25-06 Standard Test Method for Chemical Analysis...), § 98.174(b), § 98.184(b), § 98.194(c), and § 98.334(b). (2) ASTM C114-09 Standard Test Methods for... Dry Cleaning Solvent), IBR approved for § 98.6. (4) ASTM D240-02 (Reapproved 2007) Standard Test...
40 CFR 63.1348 - Compliance requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... standards and operating limits by using the test methods and procedures in §§ 63.1349 and 63.7. (1) PM... initial compliance with the PM emissions standards by using the test methods and procedures in § 63.1349(b... standards by using the performance test methods and procedures in § 63.1349(b)(2). The maximum 6-minute...
40 CFR 63.1348 - Compliance requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... standards and operating limits by using the test methods and procedures in §§ 63.1349 and 63.7. (1) PM... initial compliance with the PM emissions standards by using the test methods and procedures in § 63.1349(b... standards by using the performance test methods and procedures in § 63.1349(b)(2). The maximum 6-minute...
16 CFR 1610.3 - Summary of test method.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Summary of test method. 1610.3 Section 1610... FOR THE FLAMMABILITY OF CLOTHING TEXTILES The Standard § 1610.3 Summary of test method. The Standard... surface, and held in a special apparatus at an angle of 45°. A standardized flame shall be applied to the...
16 CFR 1610.3 - Summary of test method.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Summary of test method. 1610.3 Section 1610... FOR THE FLAMMABILITY OF CLOTHING TEXTILES The Standard § 1610.3 Summary of test method. The Standard... surface, and held in a special apparatus at an angle of 45°. A standardized flame shall be applied to the...
16 CFR 1610.3 - Summary of test method.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 16 Commercial Practices 2 2014-01-01 2014-01-01 false Summary of test method. 1610.3 Section 1610... FOR THE FLAMMABILITY OF CLOTHING TEXTILES The Standard § 1610.3 Summary of test method. The Standard... surface, and held in a special apparatus at an angle of 45°. A standardized flame shall be applied to the...
16 CFR § 1610.3 - Summary of test method.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 16 Commercial Practices 2 2013-01-01 2013-01-01 false Summary of test method. § 1610.3 Section Â... STANDARD FOR THE FLAMMABILITY OF CLOTHING TEXTILES The Standard § 1610.3 Summary of test method. The... surface, and held in a special apparatus at an angle of 45°. A standardized flame shall be applied to the...
Setting Standards for Minimum Competency Tests.
ERIC Educational Resources Information Center
Mehrens, William A.
Some general questions about minimum competency tests are discussed, and various methods of setting standards are reviewed with major attention devoted to those methods used for dichotomizing a continuum. Methods reviewed under the heading of Absolute Judgments of Test Content include Nedelsky's, Angoff's, Ebel's, and Jaeger's. These methods are…
46 CFR 63.25-9 - Incinerators.
Code of Federal Regulations, 2010 CFR
2010-10-01
... inspections and tests required by this section; (3) Have documentary proof of the laboratory's qualifications... methods and standards for testing emissions. The methods and standards for testing emissions that the...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-04
... Evaluation and testing within a risk management process 2-100 ASTM E1372-95 (2003) Standard Test Method...) Standard Title, Type of Test Method for Agar Diffusion Cell standard , Relevant Culture Screening for... Biological evaluation of medical devices - Office(s) and Part 3: Tests for genotoxicity, Division(s...
Standardization of Laboratory Methods for the PERCH Study
Karron, Ruth A.; Morpeth, Susan C.; Bhat, Niranjan; Levine, Orin S.; Baggett, Henry C.; Brooks, W. Abdullah; Feikin, Daniel R.; Hammitt, Laura L.; Howie, Stephen R. C.; Knoll, Maria Deloria; Kotloff, Karen L.; Madhi, Shabir A.; Scott, J. Anthony G.; Thea, Donald M.; Adrian, Peter V.; Ahmed, Dilruba; Alam, Muntasir; Anderson, Trevor P.; Antonio, Martin; Baillie, Vicky L.; Dione, Michel; Endtz, Hubert P.; Gitahi, Caroline; Karani, Angela; Kwenda, Geoffrey; Maiga, Abdoul Aziz; McClellan, Jessica; Mitchell, Joanne L.; Morailane, Palesa; Mugo, Daisy; Mwaba, John; Mwansa, James; Mwarumba, Salim; Nyongesa, Sammy; Panchalingam, Sandra; Rahman, Mustafizur; Sawatwong, Pongpun; Tamboura, Boubou; Toure, Aliou; Whistler, Toni; O’Brien, Katherine L.; Murdoch, David R.
2017-01-01
Abstract The Pneumonia Etiology Research for Child Health study was conducted across 7 diverse research sites and relied on standardized clinical and laboratory methods for the accurate and meaningful interpretation of pneumonia etiology data. Blood, respiratory specimens, and urine were collected from children aged 1–59 months hospitalized with severe or very severe pneumonia and community controls of the same age without severe pneumonia and were tested with an extensive array of laboratory diagnostic tests. A standardized testing algorithm and standard operating procedures were applied across all study sites. Site laboratories received uniform training, equipment, and reagents for core testing methods. Standardization was further assured by routine teleconferences, in-person meetings, site monitoring visits, and internal and external quality assurance testing. Targeted confirmatory testing and testing by specialized assays were done at a central reference laboratory. PMID:28575358
A comparison of in vitro cytotoxicity assays in medical device regulatory studies.
Liu, Xuemei; Rodeheaver, Denise P; White, Jeffrey C; Wright, Ann M; Walker, Lisa M; Zhang, Fan; Shannon, Stephen
2018-06-06
Medical device biocompatibility testing is used to evaluate the risk of adverse effects on tissues from exposure to leachates/extracts. A battery of tests is typically recommended in accordance with regulatory standards to determine if the device is biocompatible. In vitro cytotoxicity, a key element of the standards, is a required endpoint for all types of medical devices. Each validated cytotoxicity method has different methodology and acceptance criteria that could influence the selection of a specific test. In addition, some guidances are more specific than others as to the recommended test methods. For example, the International Organization for Standardization (ISO 1 ) cites preference for quantitative methods (e.g., tetrazolium (MTT/XTT), neutral red (NR), or colony formation assays (CFA)) over qualitative methods (e.g., elution, agar overlay/diffusion, or direct), while a recent ISO standard for contact lens/lens care solutions specifically requires a qualitative direct test. Qualitative methods are described in United States Pharmacopeia (USP) while quantitative CFAs are listed in Japan guidance. The aim of this review is to compare the methodologies such as test article preparation, test conditions, and criteria for six cytotoxicity methods recommended in regulatory standards in order to inform decisions on which method(s) to select during the medical device safety evaluation. Copyright © 2018. Published by Elsevier Inc.
Airside HVAC BESTEST: HVAC Air-Distribution System Model Test Cases for ASHRAE Standard 140
DOE Office of Scientific and Technical Information (OSTI.GOV)
Judkoff, Ronald; Neymark, Joel; Kennedy, Mike D.
This paper summarizes recent work to develop new airside HVAC equipment model analytical verification test cases for ANSI/ASHRAE Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. The analytical verification test method allows comparison of simulation results from a wide variety of building energy simulation programs with quasi-analytical solutions, further described below. Standard 140 is widely cited for evaluating software for use with performance-path energy efficiency analysis, in conjunction with well-known energy-efficiency standards including ASHRAE Standard 90.1, the International Energy Conservation Code, and other international standards. Airside HVAC Equipment is a common area ofmore » modelling not previously explicitly tested by Standard 140. Integration of the completed test suite into Standard 140 is in progress.« less
40 CFR 63.1348 - Compliance requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... emissions standards and operating limits by using the test methods and procedures in §§ 63.1349 and 63.7... Emission Standards and Operating Limits § 63.1348 Compliance requirements. (a) Initial Performance Test... with the PM emissions standards by using the test methods and procedures in § 63.1349(b)(1). (2...
40 CFR 63.1348 - Compliance requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... emissions standards and operating limits by using the test methods and procedures in §§ 63.1349 and 63.7... Emission Standards and Operating Limits § 63.1348 Compliance requirements. (a) Initial Performance Test... with the PM emissions standards by using the test methods and procedures in § 63.1349(b)(1). (2...
Code of Federal Regulations, 2013 CFR
2013-04-01
... (9799) t = Actual test condition temperature (O K) tO = Standardized temperature (O K) A = Coefficient... 24 Housing and Urban Development 5 2013-04-01 2013-04-01 false Air chamber test method for... HOME CONSTRUCTION AND SAFETY STANDARDS Testing § 3280.406 Air chamber test method for certification and...
Code of Federal Regulations, 2014 CFR
2014-04-01
... (9799) t = Actual test condition temperature (O K) tO = Standardized temperature (O K) A = Coefficient... 24 Housing and Urban Development 5 2014-04-01 2014-04-01 false Air chamber test method for... HOME CONSTRUCTION AND SAFETY STANDARDS Testing § 3280.406 Air chamber test method for certification and...
Code of Federal Regulations, 2012 CFR
2012-04-01
... (9799) t = Actual test condition temperature (O K) tO = Standardized temperature (O K) A = Coefficient... 24 Housing and Urban Development 5 2012-04-01 2012-04-01 false Air chamber test method for... HOME CONSTRUCTION AND SAFETY STANDARDS Testing § 3280.406 Air chamber test method for certification and...
Code of Federal Regulations, 2011 CFR
2011-04-01
... (9799) t = Actual test condition temperature (O K) tO = Standardized temperature (O K) A = Coefficient... 24 Housing and Urban Development 5 2011-04-01 2011-04-01 false Air chamber test method for... HOME CONSTRUCTION AND SAFETY STANDARDS Testing § 3280.406 Air chamber test method for certification and...
Freeman, Karoline; Tsertsvadze, Alexander; Taylor-Phillips, Sian; McCarthy, Noel; Mistry, Hema; Manuel, Rohini; Mason, James
2017-01-01
Multiplex gastrointestinal pathogen panel (GPP) tests simultaneously identify bacterial, viral and parasitic pathogens from the stool samples of patients with suspected infectious gastroenteritis presenting in hospital or the community. We undertook a systematic review to compare the accuracy of GPP tests with standard microbiology techniques. Searches in Medline, Embase, Web of Science and the Cochrane library were undertaken from inception to January 2016. Eligible studies compared GPP tests with standard microbiology techniques in patients with suspected gastroenteritis. Quality assessment of included studies used tailored QUADAS-2. In the absence of a reference standard we analysed test performance taking GPP tests and standard microbiology techniques in turn as the benchmark test, using random effects meta-analysis of proportions. No study provided an adequate reference standard with which to compare the test accuracy of GPP and conventional tests. Ten studies informed a meta-analysis of positive and negative agreement. Positive agreement across all pathogens was 0.93 (95% CI 0.90 to 0.96) when conventional methods were the benchmark and 0.68 (95% CI: 0.58 to 0.77) when GPP provided the benchmark. Negative agreement was high in both instances due to the high proportion of negative cases. GPP testing produced a greater number of pathogen-positive findings than conventional testing. It is unclear whether these additional 'positives' are clinically important. GPP testing has the potential to simplify testing and accelerate reporting when compared to conventional microbiology methods. However the impact of GPP testing upon the management, treatment and outcome of patients is poorly understood and further studies are needed to evaluate the health economic impact of GPP testing compared with standard methods. The review protocol is registered with PROSPERO as CRD42016033320.
40 CFR 60.93 - Test methods and procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Test methods and procedures. 60.93... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Hot Mix Asphalt Facilities § 60.93 Test methods and procedures. (a) In conducting the performance tests required in § 60.8...
Research on the calibration methods of the luminance parameter of radiation luminance meters
NASA Astrophysics Data System (ADS)
Cheng, Weihai; Huang, Biyong; Lin, Fangsheng; Li, Tiecheng; Yin, Dejin; Lai, Lei
2017-10-01
This paper introduces standard diffusion reflection white plate method and integrating sphere standard luminance source method to calibrate the luminance parameter. The paper compares the effects of calibration results by using these two methods through principle analysis and experimental verification. After using two methods to calibrate the same radiation luminance meter, the data obtained verifies the testing results of the two methods are both reliable. The results show that the display value using standard white plate method has fewer errors and better reproducibility. However, standard luminance source method is more convenient and suitable for on-site calibration. Moreover, standard luminance source method has wider range and can test the linear performance of the instruments.
40 CFR 60.154 - Test methods and procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Sewage Treatment Plants § 60.154 Test methods and procedures. (a) In conducting the performance tests required in § 60.8...
Annual Book of ASTM Standards, Part 23: Water; Atmospheric Analysis.
ERIC Educational Resources Information Center
American Society for Testing and Materials, Philadelphia, PA.
Standards for water and atmospheric analysis are compiled in this segment, Part 23, of the American Society for Testing and Materials (ASTM) annual book of standards. It contains all current formally approved ASTM standard and tentative test methods, definitions, recommended practices, proposed methods, classifications, and specifications. One…
78 FR 45104 - Model Manufactured Home Installation Standards: Ground Anchor Installations
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-26
... test methods for establishing working load design values of ground anchor assemblies used for new... anchor installations and establish standardized test methods to determine ground anchor performance and... currently no national test method for rating and certifying ground anchor assemblies in different soil...
40 CFR 98.254 - Monitoring and QA/QC requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... methods. (1) ASTM D4809-06 Standard Test Method for Heat of Combustion of Liquid Hydrocarbon Fuels by Bomb...) Standard Test Method for Heat of Combustion of Liquid Hydrocarbon Fuels by Bomb Calorimeter (incorporated...
40 CFR 91.6 - Reference materials.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Appendix A to Subpart D. ASTM D2699-92: Standard Test Method for Knock Characteristics of Motor Fuels by the Research Method Appendix A to Subpart D. ASTM D2700-92: Standard Test Method for Knock...
40 CFR 91.6 - Reference materials.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Appendix A to Subpart D. ASTM D2699-92: Standard Test Method for Knock Characteristics of Motor Fuels by the Research Method Appendix A to Subpart D. ASTM D2700-92: Standard Test Method for Knock...
7 CFR 3201.8 - Determining life cycle costs, environmental and health benefits, and performance.
Code of Federal Regulations, 2013 CFR
2013-01-01
... Test Method for Determining Aerobic Biodegradation of Plastic Materials Under Controlled Composting Conditions”; (2) D5864“Standard Test Method for Determining the Aerobic Aquatic Biodegradation of Lubricants...“Standard Test Method for Determining the Aerobic Aquatic Biodegradation of Lubricants or Their Components...
7 CFR 3201.8 - Determining life cycle costs, environmental and health benefits, and performance.
Code of Federal Regulations, 2012 CFR
2012-01-01
... Test Method for Determining Aerobic Biodegradation of Plastic Materials Under Controlled Composting Conditions”; (2) D5864“Standard Test Method for Determining the Aerobic Aquatic Biodegradation of Lubricants...“Standard Test Method for Determining the Aerobic Aquatic Biodegradation of Lubricants or Their Components...
7 CFR 3201.8 - Determining life cycle costs, environmental and health benefits, and performance.
Code of Federal Regulations, 2014 CFR
2014-01-01
... Test Method for Determining Aerobic Biodegradation of Plastic Materials Under Controlled Composting Conditions”; (2) D5864“Standard Test Method for Determining the Aerobic Aquatic Biodegradation of Lubricants...“Standard Test Method for Determining the Aerobic Aquatic Biodegradation of Lubricants or Their Components...
ERIC Educational Resources Information Center
Needham, Martha Elaine
2010-01-01
This research compares differences between standardized test scores in problem-based learning (PBL) classrooms and a traditional classroom for 6th grade students using a mixed-method, quasi-experimental and qualitative design. The research shows that problem-based learning is as effective as traditional teaching methods on standardized tests. The…
Standard setting: comparison of two methods.
George, Sanju; Haque, M Sayeed; Oyebode, Femi
2006-09-14
The outcome of assessments is determined by the standard-setting method used. There is a wide range of standard-setting methods and the two used most extensively in undergraduate medical education in the UK are the norm-reference and the criterion-reference methods. The aims of the study were to compare these two standard-setting methods for a multiple-choice question examination and to estimate the test-retest and inter-rater reliability of the modified Angoff method. The norm-reference method of standard-setting (mean minus 1 SD) was applied to the 'raw' scores of 78 4th-year medical students on a multiple-choice examination (MCQ). Two panels of raters also set the standard using the modified Angoff method for the same multiple-choice question paper on two occasions (6 months apart). We compared the pass/fail rates derived from the norm reference and the Angoff methods and also assessed the test-retest and inter-rater reliability of the modified Angoff method. The pass rate with the norm-reference method was 85% (66/78) and that by the Angoff method was 100% (78 out of 78). The percentage agreement between Angoff method and norm-reference was 78% (95% CI 69% - 87%). The modified Angoff method had an inter-rater reliability of 0.81-0.82 and a test-retest reliability of 0.59-0.74. There were significant differences in the outcomes of these two standard-setting methods, as shown by the difference in the proportion of candidates that passed and failed the assessment. The modified Angoff method was found to have good inter-rater reliability and moderate test-retest reliability.
Preliminary evaluation of a gel tube agglutination major cross-match method in dogs.
Villarnovo, Dania; Burton, Shelley A; Horney, Barbara S; MacKenzie, Allan L; Vanderstichel, Raphaël
2016-09-01
A major cross-match gel tube test is available for use in dogs yet has not been clinically evaluated. This study compared cross-match results obtained using the gel tube and the standard tube methods for canine samples. Study 1 included 107 canine sample donor-recipient pairings cross-match tested with the RapidVet-H method gel tube test and compared results with the standard tube method. Additionally, 120 pairings using pooled sera containing anti-canine erythrocyte antibody at various concentrations were tested with leftover blood from a hospital population to assess sensitivity and specificity of the gel tube method in comparison with the standard method. The gel tube method had a good relative specificity of 96.1% in detecting lack of agglutination (compatibility) compared to the standard tube method. Agreement between the 2 methods was moderate. Nine of 107 pairings showed agglutination/incompatibility on either test, too few to allow reliable calculation of relative sensitivity. Fifty percent of the gel tube method results were difficult to interpret due to sample spreading in the reaction and/or negative control tubes. The RapidVet-H method agreed with the standard cross-match method on compatible samples, but detected incompatibility in some sample pairs that were compatible with the standard method. Evaluation using larger numbers of incompatible pairings is needed to assess diagnostic utility. The gel tube method results were difficult to categorize due to sample spreading. Weak agglutination reactions or other factors such as centrifuge model may be responsible. © 2016 American Society for Veterinary Clinical Pathology.
Validation and Verification (V and V) Testing on Midscale Flame Resistant (FR) Test Method
2016-12-16
Method for Evaluation of Flame Resistant Clothing for Protection against Fire Simulations Using an Instrumented Manikin. Validation and...complement (not replace) the capabilities of the ASTM F1930 Standard Test Method for Evaluation of Flame Resistant Clothing for Protection against Fire ...Engineering Center (NSRDEC) to complement the ASTM F1930 Standard Test Method for Evaluation of Flame Resistant Clothing for Protection against Fire
Campbell, Rebecca; Pierce, Steven J; Sharma, Dhruv B; Shaw, Jessica; Feeney, Hannah; Nye, Jeffrey; Schelling, Kristin; Fehler-Cabral, Giannina
2017-01-01
A growing number of U.S. cities have large numbers of untested sexual assault kits (SAKs) in police property facilities. Testing older kits and maintaining current case work will be challenging for forensic laboratories, creating a need for more efficient testing methods. We evaluated selective degradation methods for DNA extraction using actual case work from a sample of previously unsubmitted SAKs in Detroit, Michigan. We randomly assigned 350 kits to either standard or selective degradation testing methods and then compared DNA testing rates and CODIS entry rates between the two groups. Continuation-ratio modeling showed no significant differences, indicating that the selective degradation method had no decrement in performance relative to customary methods. Follow-up equivalence tests indicated that CODIS entry rates for the two methods could differ by more than ±5%. Selective degradation methods required less personnel time for testing and scientific review than standard testing. © 2016 American Academy of Forensic Sciences.
Research on Generating Method of Embedded Software Test Document Based on Dynamic Model
NASA Astrophysics Data System (ADS)
Qu, MingCheng; Wu, XiangHu; Tao, YongChao; Liu, Ying
2018-03-01
This paper provides a dynamic model-based test document generation method for embedded software that provides automatic generation of two documents: test requirements specification documentation and configuration item test documentation. This method enables dynamic test requirements to be implemented in dynamic models, enabling dynamic test demand tracking to be easily generated; able to automatically generate standardized, standardized test requirements and test documentation, improved document-related content inconsistency and lack of integrity And other issues, improve the efficiency.
Humphries, Romney M; Kircher, Susan; Ferrell, Andrea; Krause, Kevin M; Malherbe, Rianna; Hsiung, Andre; Burnham, C A
2018-05-09
Expedited pathways to antimicrobial agent approval by the United States Food and Drug Administration (FDA) have led to increased delays between drug approval and the availability of FDA-cleared antimicrobial susceptibility testing (AST) devices. Antimicrobial disks for use with disk diffusion testing are among the first AST devices available to clinical laboratories. However, many laboratories are reluctant to implement a disk diffusion method for a variety of reasons, including dwindling proficiency with this method, interruptions to laboratory workflow, uncertainty surrounding the quality and reliability of a disk diffusion test, and perceived need to report an MIC to clinicians. This mini-review provides a report from the Clinical and Laboratory Standards Institute Working Group on Methods Development and Standardization on the current standards and clinical utility of disk diffusion testing. Copyright © 2018 American Society for Microbiology.
Test methods for optical disk media characteristics (for 356 mm ruggedized magneto-optic media)
NASA Technical Reports Server (NTRS)
Podio, Fernando L.
1991-01-01
Standard test methods for computer storage media characteristics are essential and allow for conformance to media interchange standards. The test methods were developed for 356 mm two-sided laminated glass substrate with a magneto-optic active layer media technology. These test methods may be used for testing other media types, but in each case their applicability must be evaluated. Test methods are included for a series of different media characteristics, including operational, nonoperational, and storage environments; mechanical and physical characteristics; and substrate, recording layer, and preformat characteristics. Tests for environmental qualification and media lifetimes are also included. The best methods include testing conditions, testing procedures, a description of the testing setup, and the required calibration procedures.
Modified Drop Tower Impact Tests for American Football Helmets.
Rush, G Alston; Prabhu, R; Rush, Gus A; Williams, Lakiesha N; Horstemeyer, M F
2017-02-19
A modified National Operating Committee on Standards for Athletic Equipment (NOCSAE) test method for American football helmet drop impact test standards is presented that would provide better assessment of a helmet's on-field impact performance by including a faceguard on the helmet. In this study, a merger of faceguard and helmet test standards is proposed. The need for a more robust systematic approach to football helmet testing procedures is emphasized by comparing representative results of the Head Injury Criterion (HIC), Severity Index (SI), and peak acceleration values for different helmets at different helmet locations under modified NOCSAE standard drop tower tests. Essentially, these comparative drop test results revealed that the faceguard adds a stiffening kinematic constraint to the shell that lessens total energy absorption. The current NOCSAE standard test methods can be improved to represent on-field helmet hits by attaching the faceguards to helmets and by including two new helmet impact locations (Front Top and Front Top Boss). The reported football helmet test method gives a more accurate representation of a helmet's performance and its ability to mitigate on-field impacts while promoting safer football helmets.
Diagnostic Profiles: A Standard Setting Method for Use with a Cognitive Diagnostic Model
ERIC Educational Resources Information Center
Skaggs, Gary; Hein, Serge F.; Wilkins, Jesse L. M.
2016-01-01
This article introduces the Diagnostic Profiles (DP) standard setting method for setting a performance standard on a test developed from a cognitive diagnostic model (CDM), the outcome of which is a profile of mastered and not-mastered skills or attributes rather than a single test score. In the DP method, the key judgment task for panelists is a…
40 CFR 60.725 - Test methods and procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Industrial Surface Coating: Surface Coating of Plastic Parts for Business Machines § 60.725 Test methods and...
40 CFR 60.725 - Test methods and procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Industrial Surface Coating: Surface Coating of Plastic Parts for Business Machines § 60.725 Test methods and...
2006-06-01
IEC Web Site - http://www.iec.org/ National Instruments Web Site - http://www.ni.com/ ASA ( Acoustical Society of America) - http://asa.aip.org/ Flow...1994 (R2004), Acoustical Terminology. ANSI S1.10-1966 (R2001), USA Standard Method for Calibration of Microphones. ANSI S1.15-1997, USA Standard...R2001), American National Standard Specification for Acoustical Calibrators. ANSI S1.9-1996 (R2001), American National Standard Instruments for
Comparison of three commercially available fit-test methods.
Janssen, Larry L; Luinenburg, D Michael; Mullins, Haskell E; Nelson, Thomas J
2002-01-01
American National Standards Institute (ANSI) standard Z88.10, Respirator Fit Testing Methods, includes criteria to evaluate new fit-tests. The standard allows generated aerosol, particle counting, or controlled negative pressure quantitative fit-tests to be used as the reference method to determine acceptability of a new test. This study examined (1) comparability of three Occupational Safety and Health Administration-accepted fit-test methods, all of which were validated using generated aerosol as the reference method; and (2) the effect of the reference method on the apparent performance of a fit-test method under evaluation. Sequential fit-tests were performed using the controlled negative pressure and particle counting quantitative fit-tests and the bitter aerosol qualitative fit-test. Of 75 fit-tests conducted with each method, the controlled negative pressure method identified 24 failures; bitter aerosol identified 22 failures; and the particle counting method identified 15 failures. The sensitivity of each method, that is, agreement with the reference method in identifying unacceptable fits, was calculated using each of the other two methods as the reference. None of the test methods met the ANSI sensitivity criterion of 0.95 or greater when compared with either of the other two methods. These results demonstrate that (1) the apparent performance of any fit-test depends on the reference method used, and (2) the fit-tests evaluated use different criteria to identify inadequately fitting respirators. Although "acceptable fit" cannot be defined in absolute terms at this time, the ability of existing fit-test methods to reject poor fits can be inferred from workplace protection factor studies.
Standard Error Estimation of 3PL IRT True Score Equating with an MCMC Method
ERIC Educational Resources Information Center
Liu, Yuming; Schulz, E. Matthew; Yu, Lei
2008-01-01
A Markov chain Monte Carlo (MCMC) method and a bootstrap method were compared in the estimation of standard errors of item response theory (IRT) true score equating. Three test form relationships were examined: parallel, tau-equivalent, and congeneric. Data were simulated based on Reading Comprehension and Vocabulary tests of the Iowa Tests of…
Determination of antenna factors using a three-antenna method at open-field test site
NASA Astrophysics Data System (ADS)
Masuzawa, Hiroshi; Tejima, Teruo; Harima, Katsushige; Morikawa, Takao
1992-09-01
Recently NIST has used the three-antenna method for calibration of the antenna factor of an antenna used for EMI measurements. This method does not require the specially designed standard antennas which are necessary in the standard field method or the standard antenna method, and can be used at an open-field test site. This paper theoretically and experimentally examines the measurement errors of this method and evaluates the precision of the antenna-factor calibration. It is found that the main source of the error is the non-ideal propagation characteristics of the test site, which should therefore be measured before the calibration. The precision of the antenna-factor calibration at the test site used in these experiments, is estimated to be 0.5 dB.
40 CFR 80.582 - What are the sampling and testing methods for the fuel marker?
Code of Federal Regulations, 2010 CFR
2010-07-01
... developed by a Voluntary Consensus-Based Standards Body, such as the American Society for Testing and... test method documentation, including a description of the technology and/or instrumentation that makes... this standard from the American Society for Testing and Materials, 100 Barr Harbor Dr., West...
40 CFR 80.582 - What are the sampling and testing methods for the fuel marker?
Code of Federal Regulations, 2011 CFR
2011-07-01
... developed by a Voluntary Consensus-Based Standards Body, such as the American Society for Testing and... test method documentation, including a description of the technology and/or instrumentation that makes... this standard from the American Society for Testing and Materials, 100 Barr Harbor Dr., West...
40 CFR 80.165 - Certification test procedures and standards.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., “Standard Test Method for Evaluating Unleaded Automotive Spark-Ignition Engine Fuel for Electronic Port Fuel.... The required test fuel must produce the accumulation of less than 100 mg of intake valve deposits on... Board, “Test Method for Evaluating Port Fuel Injector (PFI) Deposits in Vehicle Engines”, March 1, 1991...
40 CFR 80.165 - Certification test procedures and standards.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., “Standard Test Method for Evaluating Unleaded Automotive Spark-Ignition Engine Fuel for Electronic Port Fuel.... The required test fuel must produce the accumulation of less than 100 mg of intake valve deposits on... Board, “Test Method for Evaluating Port Fuel Injector (PFI) Deposits in Vehicle Engines”, March 1, 1991...
The Development of MST Test Information for the Prediction of Test Performances
ERIC Educational Resources Information Center
Park, Ryoungsun; Kim, Jiseon; Chung, Hyewon; Dodd, Barbara G.
2017-01-01
The current study proposes novel methods to predict multistage testing (MST) performance without conducting simulations. This method, called MST test information, is based on analytic derivation of standard errors of ability estimates across theta levels. We compared standard errors derived analytically to the simulation results to demonstrate the…
40 CFR 63.14 - Incorporations by reference.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Testing and Materials (ASTM), 100 Barr Harbor Drive, Post Office Box C700, West Conshohocken, PA 19428... (Reapproved 2010), Standard Test Method for Water in Petroleum Products and Bituminous Materials by...-09 Standard Test Method for Heat of Combustion of Liquid Hydrocarbon Fuels by Bomb Calorimeter...
Zhang, Dabing; Guo, Jinchao
2011-07-01
As the worldwide commercialization of genetically modified organisms (GMOs) increases and consumers concern the safety of GMOs, many countries and regions are issuing labeling regulations on GMOs and their products. Analytical methods and their standardization for GM ingredients in foods and feed are essential for the implementation of labeling regulations. To date, the GMO testing methods are mainly based on the inserted DNA sequences and newly produced proteins in GMOs. This paper presents an overview of GMO testing methods as well as their standardization. © 2011 Institute of Botany, Chinese Academy of Sciences.
Will the "Real" Proficiency Standard Please Stand Up?
ERIC Educational Resources Information Center
Baron, Joan Boykoff; And Others
Connecticut's experience with four different standard-setting methods regarding multiple choice proficiency tests is described. The methods include Angoff, Nedelsky, Borderline Group, and Contrasting Groups Methods. All Connecticut ninth graders were administered proficiency tests in reading, language arts, and mathematics. As soon as final test…
A new IRT-based standard setting method: application to eCat-listening.
García, Pablo Eduardo; Abad, Francisco José; Olea, Julio; Aguado, David
2013-01-01
Criterion-referenced interpretations of tests are highly necessary, which usually involves the difficult task of establishing cut scores. Contrasting with other Item Response Theory (IRT)-based standard setting methods, a non-judgmental approach is proposed in this study, in which Item Characteristic Curve (ICC) transformations lead to the final cut scores. eCat-Listening, a computerized adaptive test for the evaluation of English Listening, was administered to 1,576 participants, and the proposed standard setting method was applied to classify them into the performance standards of the Common European Framework of Reference for Languages (CEFR). The results showed a classification closely related to relevant external measures of the English language domain, according to the CEFR. It is concluded that the proposed method is a practical and valid standard setting alternative for IRT-based tests interpretations.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Engineers (ASHRAE) Standard 16-69, “Method of Testing for Rating Room Air Conditioners.” 2. Test conditions...-1972 and in accordance with ASHRAE Standard 16-69. 4.2Determine the electrical power input (expressed...
Code of Federal Regulations, 2011 CFR
2011-01-01
... Engineers (ASHRAE) Standard 16-69, “Method of Testing for Rating Room Air Conditioners.” 2. Test conditions...-1972 and in accordance with ASHRAE Standard 16-69. 4.2Determine the electrical power input (expressed...
40 CFR 75.6 - Incorporation by reference.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., Standard Test Method for Sulfur in Petroleum Products (General Bomb Method), for appendices A and D of this part. (2) D240-00, Standard Test Method for Heat of Combustion of Liquid Hydrocarbon Fuels by Bomb... Fuels by Bomb Calorimeter (Precision Method), for appendices D and F of this part. (47) ASTM D5865-01a...
21 CFR 175.270 - Poly(vinyl fluoride) resins.
Code of Federal Regulations, 2014 CFR
2014-04-01
...(vinyl fluoride) basic resins have an intrinsic viscosity of not less than 0.75 deciliter per gram as determined by ASTM method D1243-79, “Standard Test Method for Dilute Solution Viscosity of Vinyl Chloride... (ASTM method D1243-79, “Standard Test Method for Dilute Solution Viscosity of Vinyl Chloride Polymers...
Investigating a Judgemental Rank-Ordering Method for Maintaining Standards in UK Examinations
ERIC Educational Resources Information Center
Black, Beth; Bramley, Tom
2008-01-01
A new judgemental method of equating raw scores on two tests, based on rank-ordering scripts from both tests, has been developed by Bramley. The rank-ordering method has potential application as a judgemental standard-maintaining mechanism, because given a mark on one test (e.g. the A grade boundary mark), the equivalent mark (i.e. at the same…
Landsiedel, Robert; Ma-Hock, Lan; Van Ravenzwaay, Ben; Schulz, Markus; Wiench, Karin; Champ, Samantha; Schulte, Stefan; Wohlleben, Wendel; Oesch, Franz
2010-12-01
Titanium dioxide and zinc oxide nanomaterials, used as UV protecting agents in sunscreens, were investigated for their potential genotoxicity in in vitro and in vivo test systems. Since standard OECD test methods are designed for soluble materials and genotoxicity testing for nanomaterials is still under revision, a battery of standard tests was used, covering different endpoints. Additionally, a procedure to disperse the nanomaterials in the test media and careful characterization of the dispersed test item was added to the testing methods. No genotoxicity was observed in vitro (Ames' Salmonella gene mutation test and V79 micronucleus chromosome mutation test) or in vivo (mouse bone marrow micronucleus test and Comet DNA damage assay in lung cells from rats exposed by inhalation). These results add to the still limited data base on genotoxicity test results with nanomaterials and provide congruent results of a battery of standard OECD test methods applied to nanomaterials.
40 CFR Appendix F to Part 75 - Conversion Procedures
Code of Federal Regulations, 2010 CFR
2010-07-01
...-00, Standard Test Method for Heat of Combustion of Liquid Hydrocarbon Fuels by Bomb Calorimeter, or ASTM D4809-00, Standard Test Method for Heat of Combustion of Liquid Hydrocarbon Fuels by Bomb...
Code of Federal Regulations, 2014 CFR
2014-10-01
.... 12197 of Federal Standard 595) or white in color and the colorfastness shall be rated “good” when tested in accordance with Federal Test Method Standard No. 191 Methods 5610, 5630, 5650, and 5660. Note: On...
Code of Federal Regulations, 2010 CFR
2010-10-01
.... 12197 of Federal Standard 595) or white in color and the colorfastness shall be rated “good” when tested in accordance with Federal Test Method Standard No. 191 Methods 5610, 5630, 5650, and 5660. Note: On...
Code of Federal Regulations, 2011 CFR
2011-10-01
.... 12197 of Federal Standard 595) or white in color and the colorfastness shall be rated “good” when tested in accordance with Federal Test Method Standard No. 191 Methods 5610, 5630, 5650, and 5660. Note: On...
Code of Federal Regulations, 2012 CFR
2012-10-01
.... 12197 of Federal Standard 595) or white in color and the colorfastness shall be rated “good” when tested in accordance with Federal Test Method Standard No. 191 Methods 5610, 5630, 5650, and 5660. Note: On...
Code of Federal Regulations, 2013 CFR
2013-10-01
.... 12197 of Federal Standard 595) or white in color and the colorfastness shall be rated “good” when tested in accordance with Federal Test Method Standard No. 191 Methods 5610, 5630, 5650, and 5660. Note: On...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-29
... Ignitibility of Exterior Wall Assemblies Using a Radiant Heat Energy Source. NFPA 269 Standard Test Method P... for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption... Plastic Insulation. NFPA 285 Standard Fire Test P Method for Evaluation of Fire Propagation...
A Criterion to Control Nonlinear Error in the Mixed-Mode Bending Test
NASA Technical Reports Server (NTRS)
Reeder, James R.
2002-01-01
The mixed-mode bending test ha: been widely used to measure delamination toughness and was recently standardized by ASTM as Standard Test Method D6671-01. This simple test is a combination of the standard Mode I (opening) test and a Mode II (sliding) test. This test uses a unidirectional composite test specimen with an artificial delamination subjected to bending loads to characterize when a delamination will extend. When the displacements become large, the linear theory used to analyze the results of the test yields errors in the calcu1ated toughness values. The current standard places no limit on the specimen loading and therefore test data can be created using the standard that are significantly in error. A method of limiting the error that can be incurred in the calculated toughness values is needed. In this paper, nonlinear models of the MMB test are refined. One of the nonlinear models is then used to develop a simple criterion for prescribing conditions where thc nonlinear error will remain below 5%.
40 CFR 59.412 - Incorporations by reference.
Code of Federal Regulations, 2010 CFR
2010-07-01
... address: American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959. (1) ASTM Method C 1315-95, Standard Specification for Liquid Membrane-Forming Compounds....401, Concrete curing and sealing compound. (2) ASTM Method D 523-89, Standard Test Method for Specular...
40 CFR 60.1300 - What test methods must I use to stack test?
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false What test methods must I use to stack test? 60.1300 Section 60.1300 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Small Municipal Waste Combustion Units for...
40 CFR 60.1300 - What test methods must I use to stack test?
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 7 2012-07-01 2012-07-01 false What test methods must I use to stack test? 60.1300 Section 60.1300 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Small Municipal Waste Combustion Units for...
40 CFR 60.1300 - What test methods must I use to stack test?
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 7 2014-07-01 2014-07-01 false What test methods must I use to stack test? 60.1300 Section 60.1300 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Small Municipal Waste Combustion Units for...
40 CFR 63.2993 - What test methods must I use in conducting performance tests?
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 12 2011-07-01 2009-07-01 true What test methods must I use in conducting performance tests? 63.2993 Section 63.2993 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES National Emission Standards...
40 CFR 63.2993 - What test methods must I use in conducting performance tests?
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 12 2010-07-01 2010-07-01 true What test methods must I use in conducting performance tests? 63.2993 Section 63.2993 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES National Emission Standards...
40 CFR 60.1300 - What test methods must I use to stack test?
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 7 2013-07-01 2013-07-01 false What test methods must I use to stack test? 60.1300 Section 60.1300 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Small Municipal Waste Combustion Units for...
40 CFR 80.582 - What are the sampling and testing methods for the fuel marker?
Code of Federal Regulations, 2013 CFR
2013-07-01
... marker content of distillate fuels and how will EPA qualify or decline to qualify a test method?—(1... developed by a Voluntary Consensus-Based Standards Body, such as the American Society for Testing and... this standard from the American Society for Testing and Materials, 100 Barr Harbor Dr., West...
40 CFR 80.582 - What are the sampling and testing methods for the fuel marker?
Code of Federal Regulations, 2012 CFR
2012-07-01
... marker content of distillate fuels and how will EPA qualify or decline to qualify a test method?—(1... developed by a Voluntary Consensus-Based Standards Body, such as the American Society for Testing and... this standard from the American Society for Testing and Materials, 100 Barr Harbor Dr., West...
40 CFR 80.582 - What are the sampling and testing methods for the fuel marker?
Code of Federal Regulations, 2014 CFR
2014-07-01
... marker content of distillate fuels and how will EPA qualify or decline to qualify a test method?—(1... developed by a Voluntary Consensus-Based Standards Body, such as the American Society for Testing and... this standard from the American Society for Testing and Materials, 100 Barr Harbor Dr., West...
Development of ASTM Standard for SiC-SiC Joint Testing Final Scientific/Technical Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jacobsen, George; Back, Christina
2015-10-30
As the nuclear industry moves to advanced ceramic based materials for cladding and core structural materials for a variety of advanced reactors, new standards and test methods are required for material development and licensing purposes. For example, General Atomics (GA) is actively developing silicon carbide (SiC) based composite cladding (SiC-SiC) for its Energy Multiplier Module (EM2), a high efficiency gas cooled fast reactor. Through DOE funding via the advanced reactor concept program, GA developed a new test method for the nominal joint strength of an endplug sealed to advanced ceramic tubes, Fig. 1-1, at ambient and elevated temperatures called themore » endplug pushout (EPPO) test. This test utilizes widely available universal mechanical testers coupled with clam shell heaters, and specimen size is relatively small, making it a viable post irradiation test method. The culmination of this effort was a draft of an ASTM test standard that will be submitted for approval to the ASTM C28 ceramic committee. Once the standard has been vetted by the ceramics test community, an industry wide standard methodology to test joined tubular ceramic components will be available for the entire nuclear materials community.« less
40 CFR 92.5 - Reference materials.
Code of Federal Regulations, 2010 CFR
2010-07-01
...: (1) ASTM material. The following table sets forth material from the American Society for Testing and...., Philadelphia, PA 19103. The table follows: Document number and name 40 CFR part 92 reference ASTM D 86-95, Standard Test Method for Distillation of Petroleum Products § 92.113 ASTM D 93-94, Standard Test Methods...
Evaluation of new aquatic toxicity test methods for oil dispersants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pace, C.B.; Clark, J.R.; Bragin, G.E.
1994-12-31
Current aquatic toxicity test methods used for dispersant registration do not address real world exposure scenarios. Current test methods require 48 or 96 hour constant exposure conditions. In contrast, environmentally realistic exposures can be described as a pulse in which the initial concentration declines over time. Recent research using a specially designed testing apparatus (the California system) has demonstrated that exposure to Corexit 9527{reg_sign} under pulsed exposure conditions may be 3 to 22 times less toxic compared to continuous exposure scenarios. The objectives of this study were to compare results of toxicity tests using the California test system to resultsmore » from standardized tests, evaluate sensitivity of regional (Holmesimysis cast and Atherinops affinis) vs. standard test species (Mysidopsis bahia and Menidia beryllina) and determine if tests using the California test system and method are reproducible. All tests were conducted using Corexit 9527{reg_sign} as the test material. Standard toxicity tests conducted with M. bahia and H. cast resulted in LC50s similar to those from tests using the California apparatus. LC50s from tests conducted in the authors` laboratory with the California system and standard test species were within a factor of 2 to 6 of data previously reported for west coast species. Results of tests conducted with H. cast in the laboratory compared favorably to data reported by Singer et al. 1991.« less
40 CFR 63.805 - Performance test methods.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Section 63.805 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED) National Emission Standards for Wood Furniture Manufacturing Operations § 63.805 Performance test methods...
40 CFR 63.805 - Performance test methods.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Section 63.805 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED) National Emission Standards for Wood Furniture Manufacturing Operations § 63.805 Performance test methods...
Lemna minor (Duckweed) is commonly used in aquatic toxicity investigations. Methods for culturing and testing with reference toxicants, such as atrazine, are somewhat variable among researchers. Our goal was to develop standardized methods of culturing and testing for use with L....
NASA Technical Reports Server (NTRS)
Greene, Ben; McClure, Mark B.; Baker, David L.
2006-01-01
This work presents an overview of the International Organization for Standardization (ISO) 15859 International Standard for Space Systems Fluid Characteristics, Sampling and Test Methods Parts 1 through 13 issued in June 2004. These standards establish requirements for fluid characteristics, sampling, and test methods for 13 fluids of concern to the propellant community and propellant characterization laboratories: oxygen, hydrogen, nitrogen, helium, nitrogen tetroxide, monomethylhydrazine, hydrazine, kerosene, argon, water, ammonia, carbon dioxide, and breathing air. A comparison of the fluid characteristics, sampling, and test methods required by the ISO standards to the current military and NASA specifications, which are in use at NASA facilities and elsewhere, is presented. Many ISO standards composition limits and other content agree with those found in the applicable parts of NASA SE-S-0073, NASA SSP 30573, military performance standards and details, and Compressed Gas Association (CGA) commodity specifications. The status of a current project managed at NASA Johnson Space Center White Sands Test Facility (WSTF) to rewrite these documents is discussed.
NASA Technical Reports Server (NTRS)
Ratcliffe, James G.
2010-01-01
This paper details part of an effort focused on the development of a standardized facesheet/core peel debonding test procedure. The purpose of the test is to characterize facesheet/core peel in sandwich structure, accomplished through the measurement of the critical strain energy release rate associated with the debonding process. The specific test method selected for the standardized test procedure utilizes a single cantilever beam (SCB) specimen configuration. The objective of the current work is to develop a method for establishing SCB specimen dimensions. This is achieved by imposing specific limitations on specimen dimensions, with the objectives of promoting a linear elastic specimen response, and simplifying the data reduction method required for computing the critical strain energy release rate associated with debonding. The sizing method is also designed to be suitable for incorporation into a standardized test protocol. Preliminary application of the resulting sizing method yields practical specimen dimensions.
Applications of Automation Methods for Nonlinear Fracture Test Analysis
NASA Technical Reports Server (NTRS)
Allen, Phillip A.; Wells, Douglas N.
2013-01-01
Using automated and standardized computer tools to calculate the pertinent test result values has several advantages such as: 1. allowing high-fidelity solutions to complex nonlinear phenomena that would be impractical to express in written equation form, 2. eliminating errors associated with the interpretation and programing of analysis procedures from the text of test standards, 3. lessening the need for expertise in the areas of solid mechanics, fracture mechanics, numerical methods, and/or finite element modeling, to achieve sound results, 4. and providing one computer tool and/or one set of solutions for all users for a more "standardized" answer. In summary, this approach allows a non-expert with rudimentary training to get the best practical solution based on the latest understanding with minimum difficulty.Other existing ASTM standards that cover complicated phenomena use standard computer programs: 1. ASTM C1340/C1340M-10- Standard Practice for Estimation of Heat Gain or Loss Through Ceilings Under Attics Containing Radiant Barriers by Use of a Computer Program 2. ASTM F 2815 - Standard Practice for Chemical Permeation through Protective Clothing Materials: Testing Data Analysis by Use of a Computer Program 3. ASTM E2807 - Standard Specification for 3D Imaging Data Exchange, Version 1.0 The verification, validation, and round-robin processes required of a computer tool closely parallel the methods that are used to ensure the solution validity for equations included in test standard. The use of automated analysis tools allows the creation and practical implementation of advanced fracture mechanics test standards that capture the physics of a nonlinear fracture mechanics problem without adding undue burden or expense to the user. The presented approach forms a bridge between the equation-based fracture testing standards of today and the next generation of standards solving complex problems through analysis automation.
Standard method of test for grindability of coal by the Hardgrove-machine method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1975-01-01
A procedure is described for sampling coal, grinding in a Hardgrove grinding machine, and passing through standard sieves to determine the degree of pulverization of coals. The grindability index of the coal tested is calculated from a calibration chart prepared by plotting weight of material passing a No. 200 sieve versus the Hardgrove Grindability Index for the standard reference samples. The Hardgrove machine is shown schematically. The method for preparing and determining grindability indexes of standard reference samples is given in the appendix. (BLM)
Hearing Aid–Related Standards and Test Systems
Ravn, Gert; Preves, David
2015-01-01
Many documents describe standardized methods and standard equipment requirements in the field of audiology and hearing aids. These standards will ensure a uniform level and a high quality of both the methods and equipment used in audiological work. The standards create the basis for measuring performance in a reproducible manner and independent from how and when and by whom parameters have been measured. This article explains, and focuses on, relevant acoustic and electromagnetic compatibility parameters and describes several test systems available. PMID:27516709
Testing and Evaluation of Passive Radiation Detection Equipment for Homeland Security
West, David L.; Wood, Nathan L.; Forrester, Christina D.
2017-12-01
This article is concerned with test and evaluation methods for passive radiation detection equipment used in homeland security applications. The different types of equipment used in these applications are briefly reviewed and then test and evaluation methods discussed. The primary emphasis is on the test and evaluation standards developed by the American National Standards Institute’s N42 committees. Commonalities among the standards are then reviewed as well as examples of unique aspects for specific equipment types. Throughout, sample test configurations and results from testing and evaluation at Oak Ridge National Laboratory are given. The article concludes with a brief discussion ofmore » typical tests and evaluations not covered by the N42 standards and some examples of test and evaluation that involve the end users of the equipment.« less
Testing and Evaluation of Passive Radiation Detection Equipment for Homeland Security
DOE Office of Scientific and Technical Information (OSTI.GOV)
West, David L.; Wood, Nathan L.; Forrester, Christina D.
This article is concerned with test and evaluation methods for passive radiation detection equipment used in homeland security applications. The different types of equipment used in these applications are briefly reviewed and then test and evaluation methods discussed. The primary emphasis is on the test and evaluation standards developed by the American National Standards Institute’s N42 committees. Commonalities among the standards are then reviewed as well as examples of unique aspects for specific equipment types. Throughout, sample test configurations and results from testing and evaluation at Oak Ridge National Laboratory are given. The article concludes with a brief discussion ofmore » typical tests and evaluations not covered by the N42 standards and some examples of test and evaluation that involve the end users of the equipment.« less
Validation of a new ELISA method for in vitro potency testing of hepatitis A vaccines.
Morgeaux, S; Variot, P; Daas, A; Costanzo, A
2013-01-01
The goal of the project was to standardise a new in vitro method in replacement of the existing standard method for the determination of hepatitis A virus antigen content in hepatitis A vaccines (HAV) marketed in Europe. This became necessary due to issues with the method used previously, requiring the use of commercial test kits. The selected candidate method, not based on commercial kits, had already been used for many years by an Official Medicines Control Laboratory (OMCL) for routine testing and batch release of HAV. After a pre-qualification phase (Phase 1) that showed the suitability of the commercially available critical ELISA reagents for the determination of antigen content in marketed HAV present on the European market, an international collaborative study (Phase 2) was carried out in order to fully validate the method. Eleven laboratories took part in the collaborative study. They performed assays with the candidate standard method and, in parallel, for comparison purposes, with their own in-house validated methods where these were available. The study demonstrated that the new assay provides a more reliable and reproducible method when compared to the existing standard method. A good correlation of the candidate standard method with the in vivo immunogenicity assay in mice was shown previously for both potent and sub-potent (stressed) vaccines. Thus, the new standard method validated during the collaborative study may be implemented readily by manufacturers and OMCLs for routine batch release but also for in-process control or consistency testing. The new method was approved in October 2012 by Group of Experts 15 of the European Pharmacopoeia (Ph. Eur.) as the standard method for in vitro potency testing of HAV. The relevant texts will be revised accordingly. Critical reagents such as coating reagent and detection antibodies have been adopted by the Ph. Eur. Commission and are available from the EDQM as Ph. Eur. Biological Reference Reagents (BRRs).
Status and analysis of test standard for on-board charger
NASA Astrophysics Data System (ADS)
Hou, Shuai; Liu, Haiming; Jiang, Li; Chen, Xichen; Ma, Junjie; Zhao, Bing; Wu, Zaiyuan
2018-05-01
This paper analyzes the test standards of on -board charger (OBC). In the process of testing, we found that there exists some problems in test method and functional status, such as failed to follow up the latest test standards, estimated loosely, rectification uncertainty and consistency. Finally, putting forward some own viewpoints on these problems.
40 CFR 52.742 - Incorporation by reference.
Code of Federal Regulations, 2010 CFR
2010-07-01
... from the American Society for Testing and Materials (ASTM), 1916 Race Street, Philadelphia, PA 19103. (1) ASTM D1475-85, Standard Test Method for Density of Paint, Varnish, Lacquer, and Related Products, for § 52.741(a)(4)(i)(B)(3)(i). (2) ASTM D2369-87, Standard Test Method for Volatile Content of...
46 CFR 160.174-3 - Incorporation by reference.
Code of Federal Regulations, 2010 CFR
2010-10-01
... by reference in this subpart are: American Society for Testing and Materials (ASTM) 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959. ASTM C 177-85 (1993), Standard Test Method for Steady-State...—160.174-17 ASTM C 518-91, Standard Test Method for Steady-State Heat Flux Measurements and Thermal...
Negeri, Zelalem F; Shaikh, Mateen; Beyene, Joseph
2018-05-11
Diagnostic or screening tests are widely used in medical fields to classify patients according to their disease status. Several statistical models for meta-analysis of diagnostic test accuracy studies have been developed to synthesize test sensitivity and specificity of a diagnostic test of interest. Because of the correlation between test sensitivity and specificity, modeling the two measures using a bivariate model is recommended. In this paper, we extend the current standard bivariate linear mixed model (LMM) by proposing two variance-stabilizing transformations: the arcsine square root and the Freeman-Tukey double arcsine transformation. We compared the performance of the proposed methods with the standard method through simulations using several performance measures. The simulation results showed that our proposed methods performed better than the standard LMM in terms of bias, root mean square error, and coverage probability in most of the scenarios, even when data were generated assuming the standard LMM. We also illustrated the methods using two real data sets. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
40 CFR 61.125 - Test methods and procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Section 61.125 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standards for Radionuclide Emissions From Elemental Phosphorus Plants § 61.125 Test methods and procedures. (a) Each owner or...
16 CFR 1000.29 - Directorate for Engineering Sciences.
Code of Federal Regulations, 2010 CFR
2010-01-01
... standards, product safety tests and test methods, performance criteria, design specifications, and quality control standards for consumer products, based on engineering and scientific methods. It conducts... consumer interest groups. The Directorate conducts human factors studies and research of consumer product...
16 CFR 1000.29 - Directorate for Engineering Sciences.
Code of Federal Regulations, 2012 CFR
2012-01-01
... standards, product safety tests and test methods, performance criteria, design specifications, and quality control standards for consumer products, based on engineering and scientific methods. It conducts... consumer interest groups. The Directorate conducts human factors studies and research of consumer product...
40 CFR 60.474 - Test methods and procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... compliance with the mass standard for the blowing still. If the Administrator finds that the facility was in compliance with the mass standard during the performance test but failed to meet the zero opacity standard... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Asphalt...
40 CFR 60.474 - Test methods and procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... compliance with the mass standard for the blowing still. If the Administrator finds that the facility was in compliance with the mass standard during the performance test but failed to meet the zero opacity standard... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Asphalt...
Proficiency Standards and Cut-Scores for Language Proficiency Tests.
ERIC Educational Resources Information Center
Moy, Raymond H.
The problem of standard setting on language proficiency tests is often approached by the use of norms derived from the group being tested, a process commonly known as "grading on the curve." One particular problem with this ad hoc method of standard setting is that it will usually result in a fluctuating standard dependent on the particular group…
40 CFR 86.1 - Reference materials.
Code of Federal Regulations, 2012 CFR
2012-07-01
...) ASTM D1945-91, Standard Test Method for Analysis of Natural Gas by Gas Chromatography, IBR approved for §§ 86.113-94, 86.513-94, 86.1213-94, 86.1313-94. (iii) ASTM D2163-91, Standard Test Method for Analysis... §§ 86.113-94, 86.1213-94, 86.1313-94. (iv) ASTM D2986-95a, Reapproved 1999, Standard Practice for...
40 CFR 86.1 - Reference materials.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) ASTM D1945-91, Standard Test Method for Analysis of Natural Gas by Gas Chromatography, IBR approved for §§ 86.113-94, 86.513-94, 86.1213-94, 86.1313-94. (iii) ASTM D2163-91, Standard Test Method for Analysis... §§ 86.113-94, 86.1213-94, 86.1313-94. (iv) ASTM D2986-95a, Reapproved 1999, Standard Practice for...
Comparison of a novel fixation device with standard suturing methods for spinal cord stimulators.
Bowman, Richard G; Caraway, David; Bentley, Ishmael
2013-01-01
Spinal cord stimulation is a well-established treatment for chronic neuropathic pain of the trunk or limbs. Currently, the standard method of fixation is to affix the leads of the neuromodulation device to soft tissue, fascia or ligament, through the use of manually tying general suture. A novel semiautomated device is proposed that may be advantageous to the current standard. Comparison testing in an excised caprine spine and simulated bench top model was performed. Three tests were performed: 1) perpendicular pull from fascia of caprine spine; 2) axial pull from fascia of caprine spine; and 3) axial pull from Mylar film. Six samples of each configuration were tested for each scenario. Standard 2-0 Ethibond was compared with a novel semiautomated device (Anulex fiXate). Upon completion of testing statistical analysis was performed for each scenario. For perpendicular pull in the caprine spine, the failure load for standard suture was 8.95 lbs with a standard deviation of 1.39 whereas for fiXate the load was 15.93 lbs with a standard deviation of 2.09. For axial pull in the caprine spine, the failure load for standard suture was 6.79 lbs with a standard deviation of 1.55 whereas for fiXate the load was 12.31 lbs with a standard deviation of 4.26. For axial pull in Mylar film, the failure load for standard suture was 10.87 lbs with a standard deviation of 1.56 whereas for fiXate the load was 19.54 lbs with a standard deviation of 2.24. These data suggest a novel semiautomated device offers a method of fixation that may be utilized in lieu of standard suturing methods as a means of securing neuromodulation devices. Data suggest the novel semiautomated device in fact may provide a more secure fixation than standard suturing methods. © 2012 International Neuromodulation Society.
Wolf, Heinz; Stauffer, Tony; Chen, Shu-Chen Y; Lee, Yoojin; Forster, Ronald; Ludzinski, Miron; Kamat, Madhav; Mulhall, Brian; Guazzo, Dana Morton
2009-01-01
Part 1 of this series demonstrated that a container closure integrity test performed according to ASTM F2338-09 Standard Test Method for Nondestructive Detection of Leaks in Packages by Vacuum Decay Method using a VeriPac 325/LV vacuum decay leak tester by Packaging Technologies & Inspection, LLC (PTI) is capable of detecting leaks > or = 5.0 microm (nominal diameter) in rigid, nonporous package systems, such as prefilled glass syringes. The current study compared USP, Ph.Eur. and ISO dye ingress integrity test methods to PTI's vacuum decay technology for the detection of these same 5-, 10-, and 15-microm laser-drilled hole defects in 1-mL glass prefilled syringes. The study was performed at three test sites using several inspectors and a variety of inspection conditions. No standard dye ingress method was found to reliably identify all holed syringes. Modifications to these standard dye tests' challenge conditions increased the potential for dye ingress, and adjustments to the visual inspection environment improved dye ingress detection. However, the risk of false positive test results with dye ingress tests remained. In contrast, the nondestructive vacuum decay leak test method reliably identified syringes with holes > or = 5.0 microm.
40 CFR 60.344 - Test methods and procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Test methods and procedures. 60.344 Section 60.344 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Lime...
40 CFR 61.137 - Test methods and procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Section 61.137 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Benzene Emissions from Coke By-Product Recovery Plants § 61.137 Test methods and procedures. (a) Each owner or...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Society for Testing and Materials (ASTM) or International Standards Organization (ISO), shall be approved... description of the technology and/or instrumentation that makes the method functional. (2) Information... part 51. Anyone may purchase copies of this standard from the American Society for Testing and...
Code of Federal Regulations, 2011 CFR
2011-07-01
... Society for Testing and Materials (ASTM) or International Standards Organization (ISO), shall be approved... description of the technology and/or instrumentation that makes the method functional. (2) Information... part 51. Anyone may purchase copies of this standard from the American Society for Testing and...
Mobile Robot and Mobile Manipulator Research Towards ASTM Standards Development.
Bostelman, Roger; Hong, Tsai; Legowik, Steven
2016-01-01
Performance standards for industrial mobile robots and mobile manipulators (robot arms onboard mobile robots) have only recently begun development. Low cost and standardized measurement techniques are needed to characterize system performance, compare different systems, and to determine if recalibration is required. This paper discusses work at the National Institute of Standards and Technology (NIST) and within the ASTM Committee F45 on Driverless Automatic Guided Industrial Vehicles. This includes standards for both terminology, F45.91, and for navigation performance test methods, F45.02. The paper defines terms that are being considered. Additionally, the paper describes navigation test methods that are near ballot and docking test methods being designed for consideration within F45.02. This includes the use of low cost artifacts that can provide alternatives to using relatively expensive measurement systems.
Mobile Robot and Mobile Manipulator Research Towards ASTM Standards Development
Bostelman, Roger; Hong, Tsai; Legowik, Steven
2017-01-01
Performance standards for industrial mobile robots and mobile manipulators (robot arms onboard mobile robots) have only recently begun development. Low cost and standardized measurement techniques are needed to characterize system performance, compare different systems, and to determine if recalibration is required. This paper discusses work at the National Institute of Standards and Technology (NIST) and within the ASTM Committee F45 on Driverless Automatic Guided Industrial Vehicles. This includes standards for both terminology, F45.91, and for navigation performance test methods, F45.02. The paper defines terms that are being considered. Additionally, the paper describes navigation test methods that are near ballot and docking test methods being designed for consideration within F45.02. This includes the use of low cost artifacts that can provide alternatives to using relatively expensive measurement systems. PMID:28690359
[Research progress on mechanical performance evaluation of artificial intervertebral disc].
Li, Rui; Wang, Song; Liao, Zhenhua; Liu, Weiqiang
2018-03-01
The mechanical properties of artificial intervertebral disc (AID) are related to long-term reliability of prosthesis. There are three testing methods involved in the mechanical performance evaluation of AID based on different tools: the testing method using mechanical simulator, in vitro specimen testing method and finite element analysis method. In this study, the testing standard, testing equipment and materials of AID were firstly introduced. Then, the present status of AID static mechanical properties test (static axial compression, static axial compression-shear), dynamic mechanical properties test (dynamic axial compression, dynamic axial compression-shear), creep and stress relaxation test, device pushout test, core pushout test, subsidence test, etc. were focused on. The experimental techniques using in vitro specimen testing method and testing results of available artificial discs were summarized. The experimental methods and research status of finite element analysis were also summarized. Finally, the research trends of AID mechanical performance evaluation were forecasted. The simulator, load, dynamic cycle, motion mode, specimen and test standard would be important research fields in the future.
2001-10-01
SAE Rings, Sealing, Butadiene-Acrylonitrile ( NBR ), Rubber Fuel and Low Temperature Resistant 60 - 70 MIL-R-83248C Rubber , Fluorocarbon...KAPTON/TEFLON (COMPOSITE) WIRE I.I.10 34 VI. REFERENCE DOCUMENTS Non-Metallics MIL-HDBK-149B Military Standardization Hand Book Rubber ...ASTM D-1414 Standard Test Methods for Rubber O-Rings ASTM D-412 Type II Standard Test Methods for Vulcanized Rubber and Thermoplastic
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1969-07-01
The Fifth International Conference on Nondestructive Testing was held in Montreal, Canada, for the purpose of promoting international collaboration in all matters related to the development and use of nondestructive test methods. A total of 82 papers were selected for presentation. Session titles included: evaluation of material quality; ultrasonics - identification and measurements; thermal methods; testing of welds; visual aids in nondestructive testing; measurements of stress and elastic properties; magnetic and eddy-current methods; surface methods and neutron radiography; standardization - general; ultrasonics at elevated temperatures; applications; x-ray techniques; radiography; ultrasonic standardization; training and qualification; and, correlation of weld defects.
49 CFR 383.133 - Test methods.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 5 2014-10-01 2014-10-01 false Test methods. 383.133 Section 383.133... STANDARDS; REQUIREMENTS AND PENALTIES Tests § 383.133 Test methods. (a) All tests must be constructed in... and provides to all State Driver Licensing Agencies. (2) The State method of generating knowledge...
49 CFR 383.133 - Test methods.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 5 2012-10-01 2012-10-01 false Test methods. 383.133 Section 383.133... STANDARDS; REQUIREMENTS AND PENALTIES Tests § 383.133 Test methods. (a) All tests must be constructed in... and provides to all State Driver Licensing Agencies. (2) The State method of generating knowledge...
49 CFR 383.133 - Test methods.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 5 2011-10-01 2011-10-01 false Test methods. 383.133 Section 383.133... STANDARDS; REQUIREMENTS AND PENALTIES Tests § 383.133 Test methods. (a) All tests must be constructed in... and provides to all State Driver Licensing Agencies. (2) The State method of generating knowledge...
49 CFR 383.133 - Test methods.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 5 2013-10-01 2013-10-01 false Test methods. 383.133 Section 383.133... STANDARDS; REQUIREMENTS AND PENALTIES Tests § 383.133 Test methods. (a) All tests must be constructed in... and provides to all State Driver Licensing Agencies. (2) The State method of generating knowledge...
40 CFR 60.474 - Test methods and procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... a finding concerning compliance with the mass standard for the blowing still. If the Administrator finds that the facility was in compliance with the mass standard during the performance test but failed... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Asphalt...
40 CFR 60.474 - Test methods and procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... a finding concerning compliance with the mass standard for the blowing still. If the Administrator finds that the facility was in compliance with the mass standard during the performance test but failed... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Asphalt...
40 CFR 60.474 - Test methods and procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... a finding concerning compliance with the mass standard for the blowing still. If the Administrator finds that the facility was in compliance with the mass standard during the performance test but failed... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Asphalt...
An ROC-type measure of diagnostic accuracy when the gold standard is continuous-scale.
Obuchowski, Nancy A
2006-02-15
ROC curves and summary measures of accuracy derived from them, such as the area under the ROC curve, have become the standard for describing and comparing the accuracy of diagnostic tests. Methods for estimating ROC curves rely on the existence of a gold standard which dichotomizes patients into disease present or absent. There are, however, many examples of diagnostic tests whose gold standards are not binary-scale, but rather continuous-scale. Unnatural dichotomization of these gold standards leads to bias and inconsistency in estimates of diagnostic accuracy. In this paper, we propose a non-parametric estimator of diagnostic test accuracy which does not require dichotomization of the gold standard. This estimator has an interpretation analogous to the area under the ROC curve. We propose a confidence interval for test accuracy and a statistical test for comparing accuracies of tests from paired designs. We compare the performance (i.e. CI coverage, type I error rate, power) of the proposed methods with several alternatives. An example is presented where the accuracies of two quick blood tests for measuring serum iron concentrations are estimated and compared.
The Objective Borderline Method: A Probabilistic Method for Standard Setting
ERIC Educational Resources Information Center
Shulruf, Boaz; Poole, Phillippa; Jones, Philip; Wilkinson, Tim
2015-01-01
A new probability-based standard setting technique, the Objective Borderline Method (OBM), was introduced recently. This was based on a mathematical model of how test scores relate to student ability. The present study refined the model and tested it using 2500 simulated data-sets. The OBM was feasible to use. On average, the OBM performed well…
Duct Leakage Repeatability Testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Walker, Iain; Sherman, Max
2014-08-01
The purpose of this report is to evaluate the repeatability of the three most significant measurement techniques for duct leakage using data from the literature and recently obtained field data. We will also briefly discuss the first two factors. The main question to be answered by this study is to determine if differences in the repeatability of these tests methods is sufficient to indicate that any of these methods is so poor that it should be excluded from consideration as an allowed procedure in codes and standards. The three duct leak measurement methods assessed in this report are the twomore » duct pressurization methods that are commonly used by many practitioners and the DeltaQ technique. These are methods B, C and A, respectively of the ASTM E1554 standard. Although it would be useful to evaluate other duct leak test methods, this study focused on those test methods that are commonly used and are required in various test standards, such as BPI (2010), RESNET (2014), ASHRAE 62.2 (2013), California Title 24 (CEC 2012), DOE Weatherization and many other energy efficiency programs.« less
40 CFR 60.93 - Test methods and procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 7 2013-07-01 2013-07-01 false Test methods and procedures. 60.93 Section 60.93 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Hot Mix Asphalt...
40 CFR 60.93 - Test methods and procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 7 2012-07-01 2012-07-01 false Test methods and procedures. 60.93 Section 60.93 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Hot Mix Asphalt...
40 CFR 60.93 - Test methods and procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 7 2014-07-01 2014-07-01 false Test methods and procedures. 60.93 Section 60.93 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Hot Mix Asphalt...
40 CFR 60.93 - Test methods and procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Test methods and procedures. 60.93 Section 60.93 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Hot Mix Asphalt...
40 CFR 60.176 - Test methods and procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Test methods and procedures. 60.176 Section 60.176 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Primary Zinc...
40 CFR 60.715 - Test methods and procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false Test methods and procedures. 60.715 Section 60.715 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Magnetic Tape...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1993-06-01
The bibliography contains citations concerning standards and standard tests for water quality in drinking water sources, reservoirs, and distribution systems. Standards from domestic and international sources are presented. Glossaries and vocabularies that concern water quality analysis, testing, and evaluation are included. Standard test methods for individual elements, selected chemicals, sensory properties, radioactivity, and other chemical and physical properties are described. Discussions for proposed standards on new pollutant materials are briefly considered. (Contains a minimum of 203 citations and includes a subject term index and title list.)
Antimicrobial Testing Methods & Procedures Developed by EPA's Microbiology Laboratory
We develop antimicrobial testing methods and standard operating procedures to measure the effectiveness of hard surface disinfectants against a variety of microorganisms. Find methods and procedures for antimicrobial testing.
Obaisi, Noor Aminah; Galang-Boquiren, Maria Therese S; Evans, Carla A; Tsay, Tzong Guang Peter; Viana, Grace; Berzins, David; Megremis, Spiro
2016-07-01
The purpose of this study was to investigate the suitability of the Bend and Free Recovery (BFR) method as a standard test method to determine the transformation temperatures of heat-activated Ni-Ti orthodontic archwires. This was done by determining the transformation temperatures of two brands of heat-activated Ni-Ti orthodontic archwires using the both the BFR method and the standard method of Differential Scanning Calorimetry (DSC). The values obtained from the two methods were compared with each other and to the manufacturer-listed values. Forty heat-activated Ni-Ti archwires from both Rocky Mountain Orthodontics (RMO) and Opal Orthodontics (Opal) were tested using BFR and DSC. Round (0.016 inches) and rectangular (0.019×0.025 inches) archwires from each manufacturer were tested. The austenite start temperatures (As) and austenite finish temperatures (Af) were recorded. For four of the eight test groups, the BFR method resulted in lower standard deviations than the DSC method, and, overall, the average standard deviation for BFR testing was slightly lower than for DSC testing. Statistically significant differences were seen between the transformation temperatures obtained from the BFR and DSC test methods. However, the Af temperatures obtained from the two methods were remarkably similar with the mean differences ranging from 0.0 to 2.1°C: Af Opal round (BFR 26.7°C, DSC 27.6°C) and rectangular (BFR 27.6°C, DSC 28.6°C); Af RMO round (BFR 25.5°C, DSC 25.5°C) and rectangular (BFR 28.0°C, DSC 25.9°C). Significant differences were observed between the manufacturer-listed transformation temperatures and those obtained with BFR and DSC testing for both manufacturers. The results of this study suggest that the Bend and Free Recovery method is suitable as a standard method to evaluate the transformation temperatures of heat-activated Ni-Ti orthodontic archwires. Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Evaluating the Rank-Ordering Method for Standard Maintaining
ERIC Educational Resources Information Center
Bramley, Tom; Gill, Tim
2010-01-01
The rank-ordering method for standard maintaining was designed for the purpose of mapping a known cut-score (e.g. a grade boundary mark) on one test to an equivalent point on the test score scale of another test, using holistic expert judgements about the quality of exemplars of examinees' work (scripts). It is a novel application of an old…
Building America Top Innovations 2014 Profile: HVAC Cabinet Air Leakage Test Method
DOE Office of Scientific and Technical Information (OSTI.GOV)
none,
This 2014 Top Innovation profile describes Building America-funded research by teams and national laboratories that resulted in the development of an ASHRAE standard and a standardized testing method for testing the air leakage of HVAC air handlers and furnace cabinets and has spurred equipment manufacturers to tighten the cabinets they use for residential HVAC systems.
Evaluation of pulse-oximetry oxygen saturation taken through skin protective covering
James, Jyotsna; Tiwari, Lokesh; Upadhyay, Pramod; Sreenivas, Vishnubhatla; Bhambhani, Vikas; Puliyel, Jacob M
2006-01-01
Background The hard edges of adult finger clip probes of the pulse oximetry oxygen saturation (POOS) monitor can cause skin damage if used for prolonged periods in a neonate. Covering the skin under the probe with Micropore surgical tape or a gauze piece might prevent such injury. The study was done to see if the protective covering would affect the accuracy of the readings. Methods POOS was studied in 50 full-term neonates in the first week of life. After obtaining consent from their parents the neonates had POOS readings taken directly (standard technique) and through the protective covering. Bland-Altman plots were used to compare the new method with the standard technique. A test of repeatability for each method was also performed. Results The Bland-Altman plots suggest that there is no significant loss of accuracy when readings are taken through the protective covering. The mean difference was 0.06 (SD of 1.39) and 0.04 (SD 1.3) with Micropore and gauze respectively compared to the standard method. The mean difference was 0.22 (SD 0.23) on testing repeatability with the standard method. Conclusion Interposing Micropore or gauze does not significantly affect the accuracy of the POOS reading. The difference between the standard method and the new method was less than the difference seen on testing repeatability of the standard method. PMID:16677394
Xue, Xiaonan; Kim, Mimi Y; Castle, Philip E; Strickler, Howard D
2014-03-01
Studies to evaluate clinical screening tests often face the problem that the "gold standard" diagnostic approach is costly and/or invasive. It is therefore common to verify only a subset of negative screening tests using the gold standard method. However, undersampling the screen negatives can lead to substantial overestimation of the sensitivity and underestimation of the specificity of the diagnostic test. Our objective was to develop a simple and accurate statistical method to address this "verification bias." We developed a weighted generalized estimating equation approach to estimate, in a single model, the accuracy (eg, sensitivity/specificity) of multiple assays and simultaneously compare results between assays while addressing verification bias. This approach can be implemented using standard statistical software. Simulations were conducted to assess the proposed method. An example is provided using a cervical cancer screening trial that compared the accuracy of human papillomavirus and Pap tests, with histologic data as the gold standard. The proposed approach performed well in estimating and comparing the accuracy of multiple assays in the presence of verification bias. The proposed approach is an easy to apply and accurate method for addressing verification bias in studies of multiple screening methods. Copyright © 2014 Elsevier Inc. All rights reserved.
International Standards on stability of digital prints
NASA Astrophysics Data System (ADS)
Adelstein, Peter Z.
2010-06-01
The International Standards Organization (ISO) is a worldwide recognized standardizing body which has responsibility for standards on permanence of digital prints. This paper is an update on the progress made to date by ISO in writing test methods in this area. Three technologies are involved, namely ink jet, dye diffusion thermal transfer (dye-sublimation) and electrophotography. Two types of test methods are possible, namely comparative tests and predictive tests. To date a comparative test on water fastness has been published and final balloting is underway on a comparative test on humidity fastness. Predictive tests are being finalized on thermal stability and pollution susceptibility. The test method on thermal stability is intended to predict the print life during normal aging. One of the testing concerns is that some prints do not show significant image change in practical testing times. The test method on pollution susceptibility only deals with ozone and assumes that the reciprocity law applies. This law assumes that a long time under a low pollutant concentration is equivalent to a short time under the high concentration used in the test procedure. Longer term studies include a predictive test for light stability and the preparation of a material specification. The latter requires a decision about the proper colour target to be used and what constitutes an unacceptable colour change. Moreover, a specification which gives a predictive life is very dependent upon the conditions the print encounters and will only apply to specific levels of temperature, ozone and light.
Cantrill, Richard C
2008-01-01
Methods of analysis for products of modern biotechnology are required for national and international trade in seeds, grain and food in order to meet the labeling or import/export requirements of different nations and trading blocks. Although many methods were developed by the originators of transgenic events, governments, universities, and testing laboratories, trade is less complicated if there exists a set of international consensus-derived analytical standards. In any analytical situation, multiple methods may exist for testing for the same analyte. These methods may be supported by regional preferences and regulatory requirements. However, tests need to be sensitive enough to determine low levels of these traits in commodity grain for regulatory purposes and also to indicate purity of seeds containing these traits. The International Organization for Standardization (ISO) and its European counterpart have worked to produce a suite of standards through open, balanced and consensus-driven processes. Presently, these standards are approaching the time for their first review. In fact, ISO 21572, the "protein standard" has already been circulated for systematic review. In order to expedite the review and revision of the nucleic acid standards an ISO Technical Specification (ISO/TS 21098) was drafted to set the criteria for the inclusion of precision data from collaborative studies into the annexes of these standards.
Testing for intracycle determinism in pseudoperiodic time series.
Coelho, Mara C S; Mendes, Eduardo M A M; Aguirre, Luis A
2008-06-01
A determinism test is proposed based on the well-known method of the surrogate data. Assuming predictability to be a signature of determinism, the proposed method checks for intracycle (e.g., short-term) determinism in the pseudoperiodic time series for which standard methods of surrogate analysis do not apply. The approach presented is composed of two steps. First, the data are preprocessed to reduce the effects of seasonal and trend components. Second, standard tests of surrogate analysis can then be used. The determinism test is applied to simulated and experimental pseudoperiodic time series and the results show the applicability of the proposed test.
Issues and Methods for Standard-Setting.
ERIC Educational Resources Information Center
Hambleton, Ronald K.; And Others
Issues involved in standard setting along with methods for standard setting are reviewed, with specific reference to their relevance for criterion referenced testing. Definitions are given of continuum and state models, and traditional and normative standard setting procedures. Since continuum models are considered more appropriate for criterion…
NASA Astrophysics Data System (ADS)
Powell, P. E.
Educators have recently come to consider inquiry based instruction as a more effective method of instruction than didactic instruction. Experience based learning theory suggests that student performance is linked to teaching method. However, research is limited on inquiry teaching and its effectiveness on preparing students to perform well on standardized tests. The purpose of the study to investigate whether one of these two teaching methodologies was more effective in increasing student performance on standardized science tests. The quasi experimental quantitative study was comprised of two stages. Stage 1 used a survey to identify teaching methods of a convenience sample of 57 teacher participants and determined level of inquiry used in instruction to place participants into instructional groups (the independent variable). Stage 2 used analysis of covariance (ANCOVA) to compare posttest scores on a standardized exam by teaching method. Additional analyses were conducted to examine the differences in science achievement by ethnicity, gender, and socioeconomic status by teaching methodology. Results demonstrated a statistically significant gain in test scores when taught using inquiry based instruction. Subpopulation analyses indicated all groups showed improved mean standardized test scores except African American students. The findings benefit teachers and students by presenting data supporting a method of content delivery that increases teacher efficacy and produces students with a greater cognition of science content that meets the school's mission and goals.
Development of wheelchair caster testing equipment and preliminary testing of caster models
Mhatre, Anand; Ott, Joseph
2017-01-01
Background Because of the adverse environmental conditions present in less-resourced environments (LREs), the World Health Organization (WHO) has recommended that specialised wheelchair test methods may need to be developed to support product quality standards in these environments. A group of experts identified caster test methods as a high priority because of their common failure in LREs, and the insufficiency of existing test methods described in the International Organization for Standardization (ISO) Wheelchair Testing Standards (ISO 7176). Objectives To develop and demonstrate the feasibility of a caster system test method. Method Background literature and expert opinions were collected to identify existing caster test methods, caster failures common in LREs and environmental conditions present in LREs. Several conceptual designs for the caster testing method were developed, and through an iterative process using expert feedback, a final concept and a design were developed and a prototype was fabricated. Feasibility tests were conducted by testing a series of caster systems from wheelchairs used in LREs, and failure modes were recorded and compared to anecdotal reports about field failures. Results The new caster testing system was developed and it provides the flexibility to expose caster systems to typical conditions in LREs. Caster failures such as stem bolt fractures, fork fractures, bearing failures and tire cracking occurred during testing trials and are consistent with field failures. Conclusion The new caster test system has the capability to incorporate necessary test factors that degrade caster quality in LREs. Future work includes developing and validating a testing protocol that results in failure modes common during wheelchair use in LRE. PMID:29062762
NASA Technical Reports Server (NTRS)
Nguyen, Truong X.; Ely, Jay J.; Koppen, Sandra V.
2001-01-01
This paper describes the implementation of mode-stirred method for susceptibility testing according to the current DO-160D standard. Test results on an Engine Data Processor using the implemented procedure and the comparisons with the standard anechoic test results are presented. The comparison experimentally shows that the susceptibility thresholds found in mode-stirred method are consistently higher than anechoic. This is consistent with the recent statistical analysis finding by NIST that the current calibration procedure overstates field strength by a fixed amount. Once the test results are adjusted for this value, the comparisons with the anechoic results are excellent. The results also show that test method has excellent chamber to chamber repeatability. Several areas for improvements to the current procedure are also identified and implemented.
Tomasino, Stephen F; Fiumara, Rebecca M; Cottrill, Michele P
2006-01-01
The AOAC Use-Dilution methods do not provide procedures to enumerate the test microbe on stainless steel carriers (penicylinders) or guidance on the expected target populations of the test microbe (i.e., a performance standard). This report describes the procedures used by the U.S. Environmental Protection Agency to enumerate the test microbe (carrier counts) associated with conducting the Use-Dilution method with Staphylococcus aureus (Method 955.15) and Pseudomonas aeruginosa (Method 964.02) and the examination of historical data. The carrier count procedure involves the random selection of carriers, shearing bacterial cells from the carrier surface through sonication, and plating of serially diluted inoculum on trypticase soy agar. For each Use-Dilution test conducted, the official AOAC method was strictly followed for carrier preparation, culture initiation, test culture preparation, and carrier inoculation steps. Carrier count data from 78 Use-Dilution tests conducted over a 6-year period were compiled and analyzed. A mean carrier count of 6.6 logs (approximately 4.0 x 10(6) colony-forming units/carrier) was calculated for both S. aureus and P. aeruginosa. Of the mean values, 95% fell within +/- 2 repeatability standard deviations. The enumeration procedure and target carrier counts are desirable for standardizing the Use-Dilution methods, increasing their reproducibility, and ensuring the quality of the data.
Evaluation of a new automated instrument for pretransfusion testing.
Morelati, F; Revelli, N; Maffei, L M; Poretti, M; Santoro, C; Parravicini, A; Rebulla, P; Cole, R; Sirchia, G
1998-10-01
A number of automated devices for pretransfusion testing have recently become available. This study evaluated a fully automated device based on column agglutination technology (AutoVue System, Ortho, Raritan, NJ). Some 6747 tests including forward and reverse ABO group, Rh type and phenotype, antibody screen, autocontrol, and crossmatch were performed on random samples from 1069 blood donors, 2063 patients, and 98 newborns and cord blood. Also tested were samples from 168 immunized patients and 53 donors expressing weak or variant A and D antigens. Test results and technician times required for their performance were compared with those obtained by standard methods (manual column agglutination technology, slide, semiautomatic handler). No erroneous conclusions were found in regard to the 5028 ABO group and Rh type or phenotype determinations carried out with the device. The device rejected 1.53 percent of tests for sample inadequacy. Of the remaining 18 tests with discrepant results found with the device and not confirmed with the standard methods, 6 gave such results because of mixed-field reactions, 10 gave negative results with A2 RBCs in reverse ABO grouping, and 2 gave very weak positive reactions in antibody screening and crossmatching. In the samples from immunized patients, the device missed one weak anti-K, whereas standard methods missed five weak antibodies. In addition, 48, 34, and 31 of the 53 weak or variant antigens were detected by the device, the slide method, and the semiautomated handler, respectively. Technician time with the standard methods was 1.6 to 7 times higher than that with the device. The technical performance of the device compared favorably with that of standard methods, with a number of advantages, including in particular the saving of technician time. Sample inadequacy was the most common cause of discrepancy, which suggests that standardization of sample collection can further improve the performance of the device.
1 CFR 21.21 - General requirements: References.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 1 General Provisions 1 2010-01-01 2010-01-01 false General requirements: References. 21.21 Section... to test methods or consensus standards produced by a Federal agency that have replaced or preempted private or voluntary test methods or consensus standards in a subject matter area. (5) The reference is to...
2017-05-01
a quality program for the standardization of test methods to support comprehensive characterization and comparison of the physical and functional...1 2. MATERIALS AND METHODS ...4 2.8 SPR Methodology
7 CFR 2902.8 - Determining life cycle costs, environmental and health benefits, and performance.
Code of Federal Regulations, 2011 CFR
2011-01-01
... for Determining Aerobic Biodegradation of Plastic Materials Under Controlled Composting Conditions”; (2) D5864“Standard Test Method for Determining the Aerobic Aquatic Biodegradation of Lubricants or...“Standard Test Method for Determining the Aerobic Aquatic Biodegradation of Lubricants or Their Components...
40 CFR 258.41 - Project XL Bioreactor Landfill Projects.
Code of Federal Regulations, 2012 CFR
2012-07-01
... using the Standard Test Method for Measuring Mass per Unit Area of Geotextiles, ASTM D-5261-92... determined by the Standard Test Method for Laboratory Determination of Water (Moisture) Content of Soil and... with the provisions of the FESOP, during the entire period of leachate recirculation and the post...
40 CFR 258.41 - Project XL Bioreactor Landfill Projects.
Code of Federal Regulations, 2011 CFR
2011-07-01
... using the Standard Test Method for Measuring Mass per Unit Area of Geotextiles, ASTM D-5261-92... determined by the Standard Test Method for Laboratory Determination of Water (Moisture) Content of Soil and... with the provisions of the FESOP, during the entire period of leachate recirculation and the post...
40 CFR 258.41 - Project XL Bioreactor Landfill Projects.
Code of Federal Regulations, 2013 CFR
2013-07-01
... using the Standard Test Method for Measuring Mass per Unit Area of Geotextiles, ASTM D-5261-92... determined by the Standard Test Method for Laboratory Determination of Water (Moisture) Content of Soil and... with the provisions of the FESOP, during the entire period of leachate recirculation and the post...
USDA-ARS?s Scientific Manuscript database
Fusarium oxysporum f. sp. nivium (Fon) is a pathogen highly variable in aggressiveness that requires a standardized testing method to more accurately define isolate aggressiveness (races) and to identify resistant watermelon lines. Isolates of Fon vary in aggressiveness from weakly to highly aggres...
Evaluation of a Proposed Drift Reduction Technology High-Speed Wind Tunnel Testing Protocol
2009-03-01
05: “Standard Test Method for Determining Liquid Drop Size Characteristics in a Spray Using Optical Nonimaging Light- Scattering Instruments” 15...Method for Determining Liquid Drop Size Characteris- tics in a Spray Using Optical Nonimaging Light-Scattering Instruments,” Annual Book of ASTM Standards
Evaluation of 3 dental unit waterline contamination testing methods
Porteous, Nuala; Sun, Yuyu; Schoolfield, John
2015-01-01
Previous studies have found inconsistent results from testing methods used to measure heterotrophic plate count (HPC) bacteria in dental unit waterline (DUWL) samples. This study used 63 samples to compare the results obtained from an in-office chairside method and 2 currently used commercial laboratory HPC methods (Standard Methods 9215C and 9215E). The results suggest that the Standard Method 9215E is not suitable for application to DUWL quality monitoring, due to the detection of limited numbers of heterotrophic organisms at the required 35°C incubation temperature. The results also confirm that while the in-office chairside method is useful for DUWL quality monitoring, the Standard Method 9215C provided the most accurate results. PMID:25574718
78 FR 20695 - Walk-Through Metal Detectors and Hand-Held Metal Detectors Test Method Validation
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-05
... Detectors and Hand-Held Metal Detectors Test Method Validation AGENCY: National Institute of Justice, DOJ... ensure that the test methods in the standards are properly documented, NIJ is requesting proposals (including price quotes) for test method validation efforts from testing laboratories. NIJ is also seeking...
Comparative study between EDXRF and ASTM E572 methods using two-way ANOVA
NASA Astrophysics Data System (ADS)
Krummenauer, A.; Veit, H. M.; Zoppas-Ferreira, J.
2018-03-01
Comparison with reference method is one of the necessary requirements for the validation of non-standard methods. This comparison was made using the experiment planning technique with two-way ANOVA. In ANOVA, the results obtained using the EDXRF method, to be validated, were compared with the results obtained using the ASTM E572-13 standard test method. Fisher's tests (F-test) were used to comparative study between of the elements: molybdenum, niobium, copper, nickel, manganese, chromium and vanadium. All F-tests of the elements indicate that the null hypothesis (Ho) has not been rejected. As a result, there is no significant difference between the methods compared. Therefore, according to this study, it is concluded that the EDXRF method was approved in this method comparison requirement.
ERIC Educational Resources Information Center
Woodruff, David; Traynor, Anne; Cui, Zhongmin; Fang, Yu
2013-01-01
Professional standards for educational testing recommend that both the overall standard error of measurement and the conditional standard error of measurement (CSEM) be computed on the score scale used to report scores to examinees. Several methods have been developed to compute scale score CSEMs. This paper compares three methods, based on…
NASA Technical Reports Server (NTRS)
Ratcliffe, James G.
2010-01-01
This technical publication details part of an effort focused on the development of a standardized facesheet/core peel debonding test procedure. The purpose of the test is to characterize facesheet/core peel in sandwich structure, accomplished through the measurement of the critical strain energy release rate associated with the debonding process. Following an examination of previously developed tests and a recent evaluation of a selection of these methods, a single cantilever beam (SCB) specimen was identified as being a promising candidate for establishing such a standardized test procedure. The objective of the work described here was to begin development of a protocol for conducting a SCB test that will render the procedure suitable for standardization. To this end, a sizing methodology was developed to ensure appropriate SCB specimen dimensions are selected for a given sandwich system. Application of this method to actual sandwich systems yielded SCB specimen dimensions that would be practical for use. This study resulted in the development of a practical SCB specimen sizing method, which should be well-suited for incorporation into a standardized testing protocol.
Evaluation of pulse-oximetry oxygen saturation taken through skin protective covering.
James, Jyotsna; Tiwari, Lokesh; Upadhyay, Pramod; Sreenivas, Vishnubhatla; Bhambhani, Vikas; Puliyel, Jacob M
2006-05-06
The hard edges of adult finger clip probes of the pulse oximetry oxygen saturation (POOS) monitor can cause skin damage if used for prolonged periods in a neonate. Covering the skin under the probe with Micropore surgical tape or a gauze piece might prevent such injury. The study was done to see if the protective covering would affect the accuracy of the readings. POOS was studied in 50 full-term neonates in the first week of life. After obtaining consent from their parents the neonates had POOS readings taken directly (standard technique) and through the protective covering. Bland-Altman plots were used to compare the new method with the standard technique. A test of repeatability for each method was also performed. The Bland-Altman plots suggest that there is no significant loss of accuracy when readings are taken through the protective covering. The mean difference was 0.06 (SD of 1.39) and 0.04 (SD 1.3) with Micropore and gauze respectively compared to the standard method. The mean difference was 0.22 (SD 0.23) on testing repeatability with the standard method. Interposing Micropore or gauze does not significantly affect the accuracy of the POOS reading. The difference between the standard method and the new method was less than the difference seen on testing repeatability of the standard method.
Evaluation of a direct blood culture disk diffusion antimicrobial susceptibility test.
Doern, G V; Scott, D R; Rashad, A L; Kim, K S
1981-01-01
A total of 556 unique blood culture isolates of nonfastidious aerobic and facultatively anaerobic bacteria were examined by direct and standardized disk susceptibility test methods (4,234 antibiotic-organism comparisons). When discrepancies which could be accounted for by the variability inherent in disk diffusion susceptibility tests were excluded, the direct method demonstrated 96.8% overall agreement with the standardized method. A total of 1.6% minor, 1.5% major, and 0.1% very major discrepancies were noted. PMID:7325634
Estimating the Cost of Standardized Student Testing in the United States.
ERIC Educational Resources Information Center
Phelps, Richard P.
2000-01-01
Describes and contrasts different methods of estimating costs of standardized testing. Using a cost-accounting approach, compares gross and marginal costs and considers testing objects (test materials and services, personnel and student time, and administrative/building overhead). Social marginal costs of replacing existing tests with a national…
40 CFR 63.827 - Performance test methods.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 11 2014-07-01 2014-07-01 false Performance test methods. 63.827...) National Emission Standards for the Printing and Publishing Industry § 63.827 Performance test methods... test method for determining their values for approval by the Administrator in accordance with § 63.7(f...
77 FR 17457 - Work Group on Alternative Test Methods for Commercial Measuring Devices
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-26
... Test Methods for Commercial Measuring Devices AGENCY: National Institute of Standards and Technology... Work Group (WG) to examine alternative methods for testing the accuracy of commercial measuring devices... participates to promote uniformity among the states in laws, regulations, methods, and testing equipment that...
40 CFR 264.1034 - Test methods and procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 27 2013-07-01 2013-07-01 false Test methods and procedures. 264.1034... Air Emission Standards for Process Vents § 264.1034 Test methods and procedures. (a) Each owner or operator subject to the provisions of this subpart shall comply with the test methods and procedures...
40 CFR 264.1063 - Test methods and procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 27 2013-07-01 2013-07-01 false Test methods and procedures. 264.1063... Air Emission Standards for Equipment Leaks § 264.1063 Test methods and procedures. (a) Each owner or operator subject to the provisions of this subpart shall comply with the test methods and procedures...
Waites, Ken B; Duffy, Lynn B; Bébéar, Cécile M; Matlow, Anne; Talkington, Deborah F; Kenny, George E; Totten, Patricia A; Bade, Donald J; Zheng, Xiaotian; Davidson, Maureen K; Shortridge, Virginia D; Watts, Jeffrey L; Brown, Steven D
2012-11-01
An international multilaboratory collaborative study was conducted to develop standard media and consensus methods for the performance and quality control of antimicrobial susceptibility testing of Mycoplasma pneumoniae, Mycoplasma hominis, and Ureaplasma urealyticum using broth microdilution and agar dilution techniques. A reference strain from the American Type Culture Collection was designated for each species, which was to be used for quality control purposes. Repeat testing of replicate samples of each reference strain by participating laboratories utilizing both methods and different lots of media enabled a 3- to 4-dilution MIC range to be established for drugs in several different classes, including tetracyclines, macrolides, ketolides, lincosamides, and fluoroquinolones. This represents the first multilaboratory collaboration to standardize susceptibility testing methods and to designate quality control parameters to ensure accurate and reliable assay results for mycoplasmas and ureaplasmas that infect humans.
Study on AC loss measurements of HTS power cable for standardizing
NASA Astrophysics Data System (ADS)
Mukoyama, Shinichi; Amemiya, Naoyuki; Watanabe, Kazuo; Iijima, Yasuhiro; Mido, Nobuhiro; Masuda, Takao; Morimura, Toshiya; Oya, Masayoshi; Nakano, Tetsutaro; Yamamoto, Kiyoshi
2017-09-01
High-temperature superconducting power cables (HTS cables) have been developed for more than 20 years. In addition of the cable developments, the test methods of the HTS cables have been discussed and proposed in many laboratories and companies. Recently the test methods of the HTS cables is required to standardize and to common in the world. CIGRE made the working group (B1-31) for the discussion of the test methods of the HTS cables as a power cable, and published the recommendation of the test method. Additionally, IEC TC20 submitted the New Work Item Proposal (NP) based on the recommendation of CIGRE this year, IEC TC20 and IEC TC90 started the standardization work on Testing of HTS AC cables. However, the individual test method that used to measure a performance of HTS cables hasn’t been established as world’s common methods. The AC loss is one of the most important properties to disseminate low loss and economical efficient HTS cables in the world. We regard to establish the method of the AC loss measurements in rational and in high accuracy. Japan is at a leading position in the AC loss study, because Japanese researchers have studied on the AC loss technically and scientifically, and also developed the effective technologies for the AC loss reduction. The JP domestic commission of TC90 made a working team to discussion the methods of the AC loss measurements for aiming an international standard finally. This paper reports about the AC loss measurement of two type of the HTS conductors, such as a HTS conductor without a HTS shield and a HTS conductor with a HTS shield. The AC loss measurement method is suggested by the electrical method..
Code of Federal Regulations, 2012 CFR
2012-10-01
... Flammability of Flexible Cellular Materials Using a Radiant Heat Energy Source. (v) ASTM E 119-00a, Standard... Method for Surface Flammability of Materials Using a Radiant Heat Energy Source. (vii) ASTM E 648-00, Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source...
Code of Federal Regulations, 2013 CFR
2013-10-01
... Flammability of Flexible Cellular Materials Using a Radiant Heat Energy Source. (v) ASTM E 119-00a, Standard... Method for Surface Flammability of Materials Using a Radiant Heat Energy Source. (vii) ASTM E 648-00, Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source...
Code of Federal Regulations, 2011 CFR
2011-10-01
... Flammability of Flexible Cellular Materials Using a Radiant Heat Energy Source. (v) ASTM E 119-00a, Standard... Method for Surface Flammability of Materials Using a Radiant Heat Energy Source. (vii) ASTM E 648-00, Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source...
Code of Federal Regulations, 2014 CFR
2014-10-01
... Flammability of Flexible Cellular Materials Using a Radiant Heat Energy Source. (v) ASTM E 119-00a, Standard... Method for Surface Flammability of Materials Using a Radiant Heat Energy Source. (vii) ASTM E 648-00, Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source...
Standard test method for grindability of coal by the Hardgrove-machine method. ASTM standard
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-05-01
This test method is under the jurisdiction of ASTM Committee D-5 on Coal and Coke and is the direct responsibility of Subcommittee D05.07 on Physical Characteristics of Coal. The current edition was approved on November 10, 1997, and published May 1998. It was originally published as D 409-51. The last previous edition was D 409-93a.
Heinrich, Andreas; Teichgräber, Ulf K; Güttler, Felix V
2015-12-01
The standard ASTM F2119 describes a test method for measuring the size of a susceptibility artifact based on the example of a passive implant. A pixel in an image is considered to be a part of an image artifact if the intensity is changed by at least 30% in the presence of a test object, compared to a reference image in which the test object is absent (reference value). The aim of this paper is to simplify and accelerate the test method using a histogram-based reference value. Four test objects were scanned parallel and perpendicular to the main magnetic field, and the largest susceptibility artifacts were measured using two methods of reference value determination (reference image-based and histogram-based reference value). The results between both methods were compared using the Mann-Whitney U-test. The difference between both reference values was 42.35 ± 23.66. The difference of artifact size was 0.64 ± 0.69 mm. The artifact sizes of both methods did not show significant differences; the p-value of the Mann-Whitney U-test was between 0.710 and 0.521. A standard-conform method for a rapid, objective, and reproducible evaluation of susceptibility artifacts could be implemented. The result of the histogram-based method does not significantly differ from the ASTM-conform method.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 3 2012-01-01 2012-01-01 false Test methods. 58.644 Section 58.644 Agriculture... Procedures § 58.644 Test methods. (a) Microbiological. Microbiological determinations shall be made in accordance with the methods described in the latest edition of Standard Methods for the Examination of Dairy...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 3 2011-01-01 2011-01-01 false Test methods. 58.644 Section 58.644 Agriculture... Procedures § 58.644 Test methods. (a) Microbiological. Microbiological determinations shall be made in accordance with the methods described in the latest edition of Standard Methods for the Examination of Dairy...
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 3 2013-01-01 2013-01-01 false Test methods. 58.644 Section 58.644 Agriculture... Procedures § 58.644 Test methods. (a) Microbiological. Microbiological determinations shall be made in accordance with the methods described in the latest edition of Standard Methods for the Examination of Dairy...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 3 2010-01-01 2010-01-01 false Test methods. 58.644 Section 58.644 Agriculture... Procedures § 58.644 Test methods. (a) Microbiological. Microbiological determinations shall be made in accordance with the methods described in the latest edition of Standard Methods for the Examination of Dairy...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 3 2014-01-01 2014-01-01 false Test methods. 58.644 Section 58.644 Agriculture... Procedures § 58.644 Test methods. (a) Microbiological. Microbiological determinations shall be made in accordance with the methods described in the latest edition of Standard Methods for the Examination of Dairy...
Test Methodology to Evaluate the Safety of Materials Using Spark Incendivity
NASA Technical Reports Server (NTRS)
Buhler, Charles; Calle, Carlos; Clements, Sid; Ritz, Mindy; Starnes, Jeff
2007-01-01
For many years scientists and engineers have been searching for the proper test method to evaluate an electrostatic risk for materials used in hazardous environments. A new test standard created by the International Electrotechnical Commission is a promising addition to conventional test methods used throughout industry. The purpose of this paper is to incorporate this test into a proposed new methodology for the evaluation of materials exposed to flammable environments. However, initial testing using this new standard has uncovered some unconventional behavior in materials that conventional test methods were thought to have reconciled. For example some materials tested at higher humidities were more susceptible to incendive discharges than at lower humidity even though the surface resistivity was lower.
Harrison, Jesse P; Boardman, Carl; O'Callaghan, Kenneth; Delort, Anne-Marie; Song, Jim
2018-05-01
Plastic litter is encountered in aquatic ecosystems across the globe, including polar environments and the deep sea. To mitigate the adverse societal and ecological impacts of this waste, there has been debate on whether 'biodegradable' materials should be granted exemptions from plastic bag bans and levies. However, great care must be exercised when attempting to define this term, due to the broad and complex range of physical and chemical conditions encountered within natural ecosystems. Here, we review existing international industry standards and regional test methods for evaluating the biodegradability of plastics within aquatic environments (wastewater, unmanaged freshwater and marine habitats). We argue that current standards and test methods are insufficient in their ability to realistically predict the biodegradability of carrier bags in these environments, due to several shortcomings in experimental procedures and a paucity of information in the scientific literature. Moreover, existing biodegradability standards and test methods for aquatic environments do not involve toxicity testing or account for the potentially adverse ecological impacts of carrier bags, plastic additives, polymer degradation products or small (microscopic) plastic particles that can arise via fragmentation. Successfully addressing these knowledge gaps is a key requirement for developing new biodegradability standard(s) for lightweight carrier bags.
40 CFR 98.324 - Monitoring and QA/QC requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Procedures and Inspection Tracking System Handbook Number: PH-08-V-1, January 1, 2008 (incorporated by... paragraphs (d)(1) through (d)(2) of this section. (1) ASTM D1945-03, Standard Test Method for Analysis of... Reformed Gas by Gas Chromatography; ASTM D4891-89 (Reapproved 2006), Standard Test Method for Heating Value...
40 CFR 98.324 - Monitoring and QA/QC requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Procedures and Inspection Tracking System Handbook Number: PH-08-V-1, January 1, 2008 (incorporated by... paragraphs (d)(1) through (d)(2) of this section. (1) ASTM D1945-03, Standard Test Method for Analysis of... Reformed Gas by Gas Chromatography; ASTM D4891-89 (Reapproved 2006), Standard Test Method for Heating Value...
40 CFR 98.324 - Monitoring and QA/QC requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Procedures and Inspection Tracking System Handbook Number: PH-08-V-1, January 1, 2008 (incorporated by... ASTM D1945-03, Standard Test Method for Analysis of Natural Gas by Gas Chromatography; ASTM D1946-90... (Reapproved 2006), Standard Test Method for Heating Value of Gases in Natural Gas Range by Stoichiometric...
29 CFR 1926.752 - Site layout, site-specific erection plan and construction sequence.
Code of Federal Regulations, 2011 CFR
2011-07-01
... standard test method of field-cured samples, either 75 percent of the intended minimum compressive design... the basis of an appropriate ASTM standard test method of field-cured samples, either 75 percent of the intended minimum compressive design strength or sufficient strength to support the loads imposed during...
29 CFR 1926.752 - Site layout, site-specific erection plan and construction sequence.
Code of Federal Regulations, 2013 CFR
2013-07-01
... standard test method of field-cured samples, either 75 percent of the intended minimum compressive design... the basis of an appropriate ASTM standard test method of field-cured samples, either 75 percent of the intended minimum compressive design strength or sufficient strength to support the loads imposed during...
29 CFR 1926.752 - Site layout, site-specific erection plan and construction sequence.
Code of Federal Regulations, 2012 CFR
2012-07-01
... standard test method of field-cured samples, either 75 percent of the intended minimum compressive design... the basis of an appropriate ASTM standard test method of field-cured samples, either 75 percent of the intended minimum compressive design strength or sufficient strength to support the loads imposed during...
29 CFR 1926.752 - Site layout, site-specific erection plan and construction sequence.
Code of Federal Regulations, 2010 CFR
2010-07-01
... standard test method of field-cured samples, either 75 percent of the intended minimum compressive design... the basis of an appropriate ASTM standard test method of field-cured samples, either 75 percent of the intended minimum compressive design strength or sufficient strength to support the loads imposed during...
29 CFR 1926.752 - Site layout, site-specific erection plan and construction sequence.
Code of Federal Regulations, 2014 CFR
2014-07-01
... standard test method of field-cured samples, either 75 percent of the intended minimum compressive design... the basis of an appropriate ASTM standard test method of field-cured samples, either 75 percent of the intended minimum compressive design strength or sufficient strength to support the loads imposed during...
This document is a copy of the Federal Register publication of the November 29, 1993 Proposed Rule and Test Method & Notice of Public Hearing for the National Emission Standards for Hazardous Air Pollutants (NESHAP): Halogenated Solvent Cleaning.
Development of a standardized differential-reflective bioassay for microbial pathogens
NASA Astrophysics Data System (ADS)
Wilhelm, Jay; Auld, J. R. X.; Smith, James E.
2008-04-01
This research examines standardizing a method for the rapid/semi-automated identification of microbial contaminates. It introduces a method suited to test for food/water contamination, serology, urinalysis and saliva testing for any >1 micron sized molecule that can be effectively bound to an identifying marker with exclusivity. This optical biosensor method seeks to integrate the semi-manual distribution of a collected sample onto a "transparent" substrate array of binding sites that will then be applied to a standard optical data disk and run for analysis. The detection of most microbe species is possible in this platform because the relative scale is greater than the resolution of the standard-scale digital information on a standard CD or DVD. This paper explains the critical first stage in the advance of this detection concept. This work has concentrated on developing the necessary software component needed to perform highly sensitive small-scale recognition using the standard optical disk as a detection platform. Physical testing has made significant progress in demonstrating the ability to utilize a standard optical drive for the purposes of micro-scale detection through the exploitation of CIRC error correction. Testing has also shown a definable trend in the optimum scale and geometry of micro-arrayed attachment sites for the technology's concept to reach achievement.
An objectively-analyzed method for measuring the useful penetration of x-ray imaging systems.
Glover, Jack L; Hudson, Lawrence T
2016-06-01
The ability to detect wires is an important capability of the cabinet x-ray imaging systems that are used in aviation security as well as the portable x-ray systems that are used by domestic law enforcement and military bomb squads. A number of national and international standards describe methods for testing this capability using the so called useful penetration test metric, where wires are imaged behind different thicknesses of blocking material. Presently, these tests are scored based on human judgments of wire visibility, which are inherently subjective. We propose a new method in which the useful penetration capabilities of an x-ray system are objectively evaluated by an image processing algorithm operating on digital images of a standard test object. The algorithm advantageously applies the Radon transform for curve parameter detection that reduces the problem of wire detection from two dimensions to one. The sensitivity of the wire detection method is adjustable and we demonstrate how the threshold parameter can be set to give agreement with human-judged results. The method was developed to be used in technical performance standards and is currently under ballot for inclusion in a US national aviation security standard.
An objectively-analyzed method for measuring the useful penetration of x-ray imaging systems
Glover, Jack L.; Hudson, Lawrence T.
2016-01-01
The ability to detect wires is an important capability of the cabinet x-ray imaging systems that are used in aviation security as well as the portable x-ray systems that are used by domestic law enforcement and military bomb squads. A number of national and international standards describe methods for testing this capability using the so called useful penetration test metric, where wires are imaged behind different thicknesses of blocking material. Presently, these tests are scored based on human judgments of wire visibility, which are inherently subjective. We propose a new method in which the useful penetration capabilities of an x-ray system are objectively evaluated by an image processing algorithm operating on digital images of a standard test object. The algorithm advantageously applies the Radon transform for curve parameter detection that reduces the problem of wire detection from two dimensions to one. The sensitivity of the wire detection method is adjustable and we demonstrate how the threshold parameter can be set to give agreement with human-judged results. The method was developed to be used in technical performance standards and is currently under ballot for inclusion in a US national aviation security standard. PMID:27499586
An objectively-analyzed method for measuring the useful penetration of x-ray imaging systems
NASA Astrophysics Data System (ADS)
Glover, Jack L.; Hudson, Lawrence T.
2016-06-01
The ability to detect wires is an important capability of the cabinet x-ray imaging systems that are used in aviation security as well as the portable x-ray systems that are used by domestic law enforcement and military bomb squads. A number of national and international standards describe methods for testing this capability using the so called useful penetration test metric, where wires are imaged behind different thicknesses of blocking material. Presently, these tests are scored based on human judgments of wire visibility, which are inherently subjective. We propose a new method in which the useful penetration capabilities of an x-ray system are objectively evaluated by an image processing algorithm operating on digital images of a standard test object. The algorithm advantageously applies the Radon transform for curve parameter detection that reduces the problem of wire detection from two dimensions to one. The sensitivity of the wire detection method is adjustable and we demonstrate how the threshold parameter can be set to give agreement with human-judged results. The method was developed to be used in technical performance standards and is currently under ballot for inclusion in an international aviation security standard.
NASA Technical Reports Server (NTRS)
Marley, Mike
2008-01-01
The focus of this paper will be on the thermal balance testing for the Operationally Responsive Space Standard Bus Battery. The Standard Bus thermal design required that the battery be isolated from the bus itself. This required the battery to have its own thermal control, including heaters and a radiator surface. Since the battery was not ready for testing during the overall bus thermal balance testing, a separate test was conducted to verify the thermal design for the battery. This paper will discuss in detail, the test set up, test procedure, and results from this test. Additionally this paper will consider the methods taken to determine the heat dissipation of the battery during charge and discharge. It seems that the heat dissipation for Lithium Ion batteries is relatively unknown and hard to quantify. The methods used during test and the post test analysis to estimate the heat dissipation of the battery will be discussed.
NASA Technical Reports Server (NTRS)
Choi, Sung R.; Salem, Jonathan A.
1998-01-01
The service life of structural ceramic components is often limited by the process of slow crack growth. Therefore, it is important to develop an appropriate testing methodology for accurately determining the slow crack growth design parameters necessary for component life prediction. In addition, an appropriate test methodology can be used to determine the influences of component processing variables and composition on the slow crack growth and strength behavior of newly developed materials, thus allowing the component process to be tailored and optimized to specific needs. At the NASA Lewis Research Center, work to develop a standard test method to determine the slow crack growth parameters of advanced ceramics was initiated by the authors in early 1994 in the C 28 (Advanced Ceramics) committee of the American Society for Testing and Materials (ASTM). After about 2 years of required balloting, the draft written by the authors was approved and established as a new ASTM test standard: ASTM C 1368-97, Standard Test Method for Determination of Slow Crack Growth Parameters of Advanced Ceramics by Constant Stress-Rate Flexural Testing at Ambient Temperature. Briefly, the test method uses constant stress-rate testing to determine strengths as a function of stress rate at ambient temperature. Strengths are measured in a routine manner at four or more stress rates by applying constant displacement or loading rates. The slow crack growth parameters required for design are then estimated from a relationship between strength and stress rate. This new standard will be published in the Annual Book of ASTM Standards, Vol. 15.01, in 1998. Currently, a companion draft ASTM standard for determination of the slow crack growth parameters of advanced ceramics at elevated temperatures is being prepared by the authors and will be presented to the committee by the middle of 1998. Consequently, Lewis will maintain an active leadership role in advanced ceramics standardization within ASTM. In addition, the authors have been and are involved with several international standardization organizations including the Versailles Project on Advanced Materials and Standards (VAMAS), the International Energy Agency (IEA), and the International Organization for Standardization (ISO). The associated standardization activities involve fracture toughness, strength, elastic modulus, and the machining of advanced ceramics.
Environmentally safe aviation fuels
NASA Technical Reports Server (NTRS)
Liberio, Patricia D.
1995-01-01
In response to the Air Force directive to remove Ozone Depleting Chemicals (ODC's) from military specifications and Defense Logistics Agency's Hazardous Waste Minimization Program, we are faced with how to ensure a quality aviation fuel without using such chemicals. Many of these chemicals are found throughout the fuel and fuel related military specifications and are part of test methods that help qualify the properties and quality of the fuels before they are procured. Many years ago there was a directive for military specifications to use commercially standard test methods in order to provide standard testing in private industry and government. As a result the test methods used in military specifications are governed by the American Society of Testing and Materials (ASTM). The Air Force has been very proactive in the removal or replacement of the ODC's and hazardous materials in these test methods. For example, ASTM D3703 (Standard Test Method for Peroxide Number of Aviation Turbine Fuels), requires the use of Freon 113, a known ODC. A new rapid, portable hydroperoxide test for jet fuels similar to ASTM D3703 that does not require the use of ODC's has been developed. This test has proved, in limited testing, to be a viable substitute method for ASTM D3703. The Air Force is currently conducting a round robin to allow the method to be accepted by ASTM and therefore replace the current method. This paper will describe the Air Force's initiatives to remove ODC's and hazardous materials from the fuel and fuel related military specifications that the Air Force Wright Laboratory.
Leak Rate Quantification Method for Gas Pressure Seals with Controlled Pressure Differential
NASA Technical Reports Server (NTRS)
Daniels, Christopher C.; Braun, Minel J.; Oravec, Heather A.; Mather, Janice L.; Taylor, Shawn C.
2015-01-01
An enhancement to the pressure decay leak rate method with mass point analysis solved deficiencies in the standard method. By adding a control system, a constant gas pressure differential across the test article was maintained. As a result, the desired pressure condition was met at the onset of the test, and the mass leak rate and measurement uncertainty were computed in real-time. The data acquisition and control system were programmed to automatically stop when specified criteria were met. Typically, the test was stopped when a specified level of measurement uncertainty was attained. Using silicone O-ring test articles, the new method was compared with the standard method that permitted the downstream pressure to be non-constant atmospheric pressure. The two methods recorded comparable leak rates, but the new method recorded leak rates with significantly lower measurement uncertainty, statistical variance, and test duration. Utilizing this new method in leak rate quantification, projects will reduce cost and schedule, improve test results, and ease interpretation between data sets.
40 CFR 63.945 - Test methods and procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 11 2014-07-01 2014-07-01 false Test methods and procedures. 63.945...) National Emission Standards for Surface Impoundments § 63.945 Test methods and procedures. (a) Procedure...) The test shall be conducted in accordance with the procedures specified in Method 21 of 40 CFR part 60...
NASA Astrophysics Data System (ADS)
Lugovtsova, Y. D.; Soldatov, A. I.
2016-01-01
Three different methods for pile integrity testing are proposed to compare on a cylindrical homogeneous polyamide specimen. The methods are low strain pile integrity testing, multichannel pile integrity testing and testing with a shaker system. Since the low strain pile integrity testing is well-established and standardized method, the results from it are used as a reference for other two methods.
Development of a qualification standard for adhesives used in hybrid microcircuits
NASA Technical Reports Server (NTRS)
Licari, J. J.; Weigand, B. L.; Soykin, C. A.
1981-01-01
Improved qualification standards and test procedures for adhesives used in microelectronic packaging are developed. The test methods in specification for the Selection and Use of Organic Adhesives in Hybrid Microcircuits are reevaluated versus industry and government requirements. Four electrically insulative and four electrically conductive adhesives used in the assembly of hybrid microcircuits are selected to evaluate the proposed revised test methods. An estimate of the cost to perform qualification testing of an adhesive to the requirements of the revised specification is also prepared.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-30
.... Test Procedure for Commercial Prerinse Spray Valves 4. Design Requirements for Showerheads 5... procedures prescribed or amended under this section shall be reasonably designed to produce test results...] American Society for Testing and Materials [ASTM] Standard F2324, entitled `Standard Test Method for Pre...
Ashby, R
1994-01-01
CEC Directives have been implemented for plastics materials and articles intended to come into contact with foodstuffs. These introduce limits upon the overall migration from plastics into food and food simulants. In addition, specific migration limits or composition limits for free monomer in the final article, have been set for some monomers. Agreed test methods are required to allow these Directives to be respected. CEN, the European Committee for Standardization, has created a working group to develop suitable test methods. This is 'Working Group 5, Chemical Methods of Test', of CEN Technical Committee TC 194, Utensils in contact with food. This group has drafted a ten part standard for determining overall migration into aqueous and fatty food simulants by total immersion, by standard cell, by standard pouch and by filling. This draft standard has been approved by CEN TC 194 for circulation for public comment as a provisional standard, i.e. as an ENV. Further parts of this standard are in preparation for determining overall migration at high temperatures, etc. Simultaneously, Working Group 5 is cooperating with the BCR (Community Bureau of Reference) to produce reference materials with certified values of overall migration. CEN TC 194 Working Group 5 is also drafting methods for monomers subject to limitation in Directive 90/128/EEC. Good progress is being made on the monomers of highest priority but it is recognized that developing methods for all the monomers subject to limitation would take many years. Therefore, collaboration with the BCR, the Council of Europe and others is taking place to accelerate method development.
ERIC Educational Resources Information Center
Cramer, Stephen E.
A standard-setting procedure was developed for the Georgia Teacher Certification Testing Program as tests in 30 teaching fields were revised. A list of important characteristics of a standard-setting procedure was derived, drawing on the work of R. A. Berk (1986). The best method was found to be a highly formalized judgmental, empirical Angoff…
49 CFR 178.608 - Vibration standard.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 3 2011-10-01 2011-10-01 false Vibration standard. 178.608 Section 178.608... Packagings and Packages § 178.608 Vibration standard. (a) Each packaging must be capable of withstanding, without rupture or leakage, the vibration test procedure outlined in this section. (b) Test method. (1...
49 CFR 178.608 - Vibration standard.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 3 2013-10-01 2013-10-01 false Vibration standard. 178.608 Section 178.608... Packagings and Packages § 178.608 Vibration standard. (a) Each packaging must be capable of withstanding, without rupture or leakage, the vibration test procedure outlined in this section. (b) Test method. (1...
49 CFR 178.608 - Vibration standard.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 3 2014-10-01 2014-10-01 false Vibration standard. 178.608 Section 178.608... Packagings and Packages § 178.608 Vibration standard. (a) Each packaging must be capable of withstanding, without rupture or leakage, the vibration test procedure outlined in this section. (b) Test method. (1...
49 CFR 178.608 - Vibration standard.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 3 2012-10-01 2012-10-01 false Vibration standard. 178.608 Section 178.608... Packagings and Packages § 178.608 Vibration standard. (a) Each packaging must be capable of withstanding, without rupture or leakage, the vibration test procedure outlined in this section. (b) Test method. (1...
Workshop on standards in biomass for energy and chemicals: proceedings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Milne, T.A.
1984-11-01
In the course of reviewing standards literature, visiting prominent laboratories and research groups, attending biomass meetings and corresponding widely, a whole set of standards needs was identified, the most prominent of which were: biomass standard reference materials, research materials and sample banks; special collections of microorganisms, clonal material, algae, etc.; standard methods of characterization of substrates and biomass fuels; standard tests and methods for the conversion and end-use of biomass; standard protocols for the description, harvesting, preparation, storage, and measurement of productivity of biomass materials in the energy context; glossaries of terms; development of special tests for assay of enzymaticmore » activity and related processes. There was also a recognition of the need for government, professional and industry support of concensus standards development and the dissemination of information on standards. Some 45 biomass researchers and managers met with key NBS staff to identify and prioritize standards needs. This was done through three working panels: the Panel on Standard Reference Materials (SRM's), Research Materials (RM's), and Sample Banks; the Panel on Production and Characterization; and the Panel on Tests and Methods for Conversion and End Use. This report gives a summary of the action items in standards development recommended unanimously by the workshop attendees. The proceedings of the workshop, and an appendix, contain an extensive written record of the findings of the workshop panelists and others regarding presently existing standards and standards issues and needs. Separate abstracts have been prepared for selected papers for inclusion in the Energy Database.« less
40 CFR 98.324 - Monitoring and QA/QC requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Tracking System Handbook Number: PH-08-V-1, January 1, 2008 (incorporated by reference, see § 98.7). You... paragraphs (d)(1) through (d)(2) of this section. (1) ASTM D1945-03, Standard Test Method for Analysis of... Reformed Gas by Gas Chromatography; ASTM D4891-89 (Reapproved 2006), Standard Test Method for Heating Value...
46 CFR 164.120-5 - Incorporation by reference.
Code of Federal Regulations, 2012 CFR
2012-10-01
...), IBR approved for § 164.120-7 (“ASTM D 543”). (2) ASTM D 570-98 (Reapproved 2005), Standard Test Method for Water Absorption of Plastics, (approved November 1, 2005), IBR approved for § 164.120-7 (“ASTM D 570”). (3) ASTM D 638-08, Standard Test Method for Tensile Properties of Plastics, (approved April 1...
Wort free amino nitrogen analysis adapted to a microplate format
USDA-ARS?s Scientific Manuscript database
The standard method for determining wort free amino nitrogen content calls for the use of test tubes and glass marbles, as well as boiling and 20°C water baths. In this paper we describe how the standard method can be updated and streamlined by replacing water baths, test tubes and marbles with a th...
40 CFR 63.565 - Test methods and procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Test methods and procedures. 63.565... Standards for Marine Tank Vessel Loading Operations § 63.565 Test methods and procedures. (a) Performance... as possible to the connection with the marine tank vessel; and (3) During the performance test...
40 CFR 63.565 - Test methods and procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 10 2012-07-01 2012-07-01 false Test methods and procedures. 63.565... Standards for Marine Tank Vessel Loading Operations § 63.565 Test methods and procedures. (a) Performance... as possible to the connection with the marine tank vessel; and (3) During the performance test...
40 CFR 63.565 - Test methods and procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 10 2014-07-01 2014-07-01 false Test methods and procedures. 63.565... Standards for Marine Tank Vessel Loading Operations § 63.565 Test methods and procedures. (a) Performance... as possible to the connection with the marine tank vessel; and (3) During the performance test...
40 CFR 63.565 - Test methods and procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 10 2013-07-01 2013-07-01 false Test methods and procedures. 63.565... Standards for Marine Tank Vessel Loading Operations § 63.565 Test methods and procedures. (a) Performance... as possible to the connection with the marine tank vessel; and (3) During the performance test...
40 CFR 63.565 - Test methods and procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 9 2011-07-01 2011-07-01 false Test methods and procedures. 63.565... Standards for Marine Tank Vessel Loading Operations § 63.565 Test methods and procedures. (a) Performance... as possible to the connection with the marine tank vessel; and (3) During the performance test...
10 CFR 431.263 - Materials incorporated by reference.
Code of Federal Regulations, 2011 CFR
2011-01-01
... Society for Testing and Materials (ASTM) Standard F2324-03, “Standard Test Method for Prerinse Spray..., Forrestal Building, Room 1J-018 (Resource Room of the Building Technologies Program), 1000 Independence...
10 CFR 431.263 - Materials incorporated by reference.
Code of Federal Regulations, 2010 CFR
2010-01-01
... Society for Testing and Materials (ASTM) Standard F2324-03, “Standard Test Method for Prerinse Spray..., Forrestal Building, Room 1J-018 (Resource Room of the Building Technologies Program), 1000 Independence...
40 CFR 89.6 - Reference materials.
Code of Federal Regulations, 2014 CFR
2014-07-01
... July 1, 2009), Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (the Calculation of Dynamic Viscosity), IBR approved for appendix A to subpart D. (6) ASTM D613-95, Standard Test...
40 CFR 89.6 - Reference materials.
Code of Federal Regulations, 2012 CFR
2012-07-01
... July 1, 2009), Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (the Calculation of Dynamic Viscosity), IBR approved for appendix A to subpart D. (6) ASTM D613-95, Standard Test...
40 CFR 89.6 - Reference materials.
Code of Federal Regulations, 2013 CFR
2013-07-01
... July 1, 2009), Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (the Calculation of Dynamic Viscosity), IBR approved for appendix A to subpart D. (6) ASTM D613-95, Standard Test...
Preparation of calibrated test packages for particle impact noise detection
NASA Technical Reports Server (NTRS)
1977-01-01
A standard calibration method for any particle impact noise detection (PIND) test system used to detect loose particles responsible for failures in hybrid circuits was developed along with a procedure for preparing PIND standard test devices. Hybrid packages were seeded with a single gold ball, hermetically sealed, leak tested, and PIND tested. Conclusions are presented.
40 CFR 63.925 - Test methods and procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 11 2014-07-01 2014-07-01 false Test methods and procedures. 63.925...) National Emission Standards for Containers § 63.925 Test methods and procedures. (a) Procedures for... be conducted in accordance with the procedures specified in Method 21 of 40 CFR part 60, appendix A...
40 CFR 63.750 - Test methods and procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 11 2014-07-01 2014-07-01 false Test methods and procedures. 63.750...) National Emission Standards for Aerospace Manufacturing and Rework Facilities § 63.750 Test methods and... engineering reference texts, or other equivalent methods. (2) The composite vapor pressure of a blended hand...
40 CFR 63.805 - Performance test methods.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 11 2014-07-01 2014-07-01 false Performance test methods. 63.805...) National Emission Standards for Wood Furniture Manufacturing Operations § 63.805 Performance test methods. (a)(1) The EPA Method 311 of appendix A of part 63 shall be used in conjunction with formulation data...
Characterization of Triaxial Braided Composite Material Properties for Impact Simulation
NASA Technical Reports Server (NTRS)
Roberts, Gary D.; Goldberg, Robert K.; Biniendak, Wieslaw K.; Arnold, William A.; Littell, Justin D.; Kohlman, Lee W.
2009-01-01
The reliability of impact simulations for aircraft components made with triaxial braided carbon fiber composites is currently limited by inadequate material property data and lack of validated material models for analysis. Improvements to standard quasi-static test methods are needed to account for the large unit cell size and localized damage within the unit cell. The deformation and damage of a triaxial braided composite material was examined using standard quasi-static in-plane tension, compression, and shear tests. Some modifications to standard test specimen geometries are suggested, and methods for measuring the local strain at the onset of failure within the braid unit cell are presented. Deformation and damage at higher strain rates is examined using ballistic impact tests on 61- by 61- by 3.2-mm (24- by 24- by 0.125-in.) composite panels. Digital image correlation techniques were used to examine full-field deformation and damage during both quasi-static and impact tests. An impact analysis method is presented that utilizes both local and global deformation and failure information from the quasi-static tests as input for impact simulations. Improvements that are needed in test and analysis methods for better predictive capability are examined.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 6 2012-07-01 2012-07-01 false Test methods. 59.207 Section 59.207 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL... Compound Emission Standards for Consumer Products § 59.207 Test methods. Each manufacturer or importer...
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Test methods. 59.207 Section 59.207 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL... Compound Emission Standards for Consumer Products § 59.207 Test methods. Each manufacturer or importer...
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 6 2014-07-01 2014-07-01 false Test methods. 59.207 Section 59.207 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL... Compound Emission Standards for Consumer Products § 59.207 Test methods. Each manufacturer or importer...
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 5 2011-07-01 2011-07-01 false Test methods. 59.207 Section 59.207 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL... Compound Emission Standards for Consumer Products § 59.207 Test methods. Each manufacturer or importer...
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 6 2013-07-01 2013-07-01 false Test methods. 59.207 Section 59.207 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL... Compound Emission Standards for Consumer Products § 59.207 Test methods. Each manufacturer or importer...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-18
... (General Bomb Method), IBR approved for appendix A to subpart D. (4) ASTM D287-92, Standard Test Method for... Method for Sulfur in Petroleum Products (General Bomb Method), IBR approved for Sec. 94.108. (4) ASTM...
Current status of antifungal susceptibility testing methods.
Arikan, Sevtap
2007-11-01
Antifungal susceptibility testing is a very dynamic field of medical mycology. Standardization of in vitro susceptibility tests by the Clinical and Laboratory Standards Institute (CLSI) and the European Committee for Antimicrobial Susceptibility Testing (EUCAST), and current availability of reference methods constituted the major remarkable steps in the field. Based on the established minimum inhibitory concentration (MIC) breakpoints, it is now possible to determine the susceptibilities of Candida strains to fluconazole, itraconazole, voriconazole, and flucytosine. Moreover, utility of fluconazole antifungal susceptibility tests as an adjunct in optimizing treatment of candidiasis has now been validated. While the MIC breakpoints and clinical significance of susceptibility testing for the remaining fungi and antifungal drugs remain yet unclear, modifications of the available methods as well as other methodologies are being intensively studied to overcome the present drawbacks and limitations. Among the other methods under investigation are Etest, colorimetric microdilution, agar dilution, determination of fungicidal activity, flow cytometry, and ergosterol quantitation. Etest offers the advantage of practical application and favorable agreement rates with the reference methods that are frequently above acceptable limits. However, MIC breakpoints for Etest remain to be evaluated and established. Development of commercially available, standardized colorimetric panels that are based on CLSI method parameters has added more to the antifungal susceptibility testing armamentarium. Flow cytometry, on the other hand, appears to offer rapid susceptibility testing but requires specified equipment and further evaluation for reproducibility and standardization. Ergosterol quantitation is another novel approach, which appears potentially beneficial particularly in discrimination of azole-resistant isolates from heavy trailers. The method is yet investigational and requires to be further studied. Developments in methodology and applications of antifungal susceptibility testing will hopefully provide enhanced utility in clinical guidance of antifungal therapy. However, and particularly in immunosuppressed host, in vitro susceptibility is and will remain only one of several factors that influence clinical outcome.
Determination of service standard time for liquid waste parameter in certification institution
NASA Astrophysics Data System (ADS)
Sembiring, M. T.; Kusumawaty, D.
2018-02-01
Baristand Industry Medan is a technical implementation unit under the Industrial and Research and Development Agency, the Ministry of Industry. One of the services often used in Baristand Industry Medan is liquid waste testing service. The company set the standard of service 9 working days for testing services. At 2015, 89.66% on testing services liquid waste does not meet the specified standard of services company. The purpose of this research is to specify the standard time of each parameter in testing services liquid waste. The method used is the stopwatch time study. There are 45 test parameters in liquid waste laboratory. The measurement of the time done 4 samples per test parameters using the stopwatch. From the measurement results obtained standard time that the standard Minimum Service test of liquid waste is 13 working days if there is testing E. coli.
Alternative Test Methods for Electronic Parts
NASA Technical Reports Server (NTRS)
Plante, Jeannette
2004-01-01
It is common practice within NASA to test electronic parts at the manufacturing lot level to demonstrate, statistically, that parts from the lot tested will not fail in service using generic application conditions. The test methods and the generic application conditions used have been developed over the years through cooperation between NASA, DoD, and industry in order to establish a common set of standard practices. These common practices, found in MIL-STD-883, MIL-STD-750, military part specifications, EEE-INST-002, and other guidelines are preferred because they are considered to be effective and repeatable and their results are usually straightforward to interpret. These practices can sometimes be unavailable to some NASA projects due to special application conditions that must be addressed, such as schedule constraints, cost constraints, logistical constraints, or advances in the technology that make the historical standards an inappropriate choice for establishing part performance and reliability. Alternate methods have begun to emerge and to be used by NASA programs to test parts individually or as part of a system, especially when standard lot tests cannot be applied. Four alternate screening methods will be discussed in this paper: Highly accelerated life test (HALT), forward voltage drop tests for evaluating wire-bond integrity, burn-in options during or after highly accelerated stress test (HAST), and board-level qualification.
NASA Technical Reports Server (NTRS)
2009-01-01
This Interim Standard establishes requirements for evaluation, testing, and selection of materials that are intended for use in space vehicles, associated Ground Support Equipment (GSE), and facilities used during assembly, test, and flight operations. Included are requirements, criteria, and test methods for evaluating the flammability, offgassing, and compatibility of materials.
Standardized Tests of Handwriting Readiness: A Systematic Review of the Literature
ERIC Educational Resources Information Center
van Hartingsveldt, Margo J.; de Groot, Imelda J. M.; Aarts, Pauline B. M.; Nijhuis-van der Sanden, Maria W. G.
2011-01-01
Aim: To establish if there are psychometrically sound standardized tests or test items to assess handwriting readiness in 5- and 6-year-old children on the levels of occupations activities/tasks and performance. Method: Electronic databases were searched to identify measurement instruments. Tests were included in a systematic review if: (1)…
Boardman, Carl; O'Callaghan, Kenneth; Delort, Anne-Marie; Song, Jim
2018-01-01
Plastic litter is encountered in aquatic ecosystems across the globe, including polar environments and the deep sea. To mitigate the adverse societal and ecological impacts of this waste, there has been debate on whether ‘biodegradable' materials should be granted exemptions from plastic bag bans and levies. However, great care must be exercised when attempting to define this term, due to the broad and complex range of physical and chemical conditions encountered within natural ecosystems. Here, we review existing international industry standards and regional test methods for evaluating the biodegradability of plastics within aquatic environments (wastewater, unmanaged freshwater and marine habitats). We argue that current standards and test methods are insufficient in their ability to realistically predict the biodegradability of carrier bags in these environments, due to several shortcomings in experimental procedures and a paucity of information in the scientific literature. Moreover, existing biodegradability standards and test methods for aquatic environments do not involve toxicity testing or account for the potentially adverse ecological impacts of carrier bags, plastic additives, polymer degradation products or small (microscopic) plastic particles that can arise via fragmentation. Successfully addressing these knowledge gaps is a key requirement for developing new biodegradability standard(s) for lightweight carrier bags. PMID:29892374
NASA Astrophysics Data System (ADS)
Connick, Robert J.
Accurate measurement of normal incident transmission loss is essential for the acoustic characterization of building materials. In this research, a method of measuring normal incidence sound transmission loss proposed by Salissou et al. as a complement to standard E2611-09 of the American Society for Testing and Materials [Standard Test Method for Measurement of Normal Incidence Sound Transmission of Acoustical Materials Based on the Transfer Matrix Method (American Society for Testing and Materials, New York, 2009)] is verified. Two sam- ples from the original literature are used to verify the method as well as a Filtros RTM sample. Following the verification, several nano-material Aerogel samples are measured.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Judkoff, R.; Neymark, J.
2013-07-01
ANSI/ASHRAE Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs applies the IEA BESTEST building thermal fabric test cases and example simulation results originally published in 1995. These software accuracy test cases and their example simulation results, which comprise the first test suite adapted for the initial 2001 version of Standard 140, are approaching their 20th anniversary. In response to the evolution of the state of the art in building thermal fabric modeling since the test cases and example simulation results were developed, work is commencing to update the normative test specification and themore » informative example results.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Judkoff, R.; Neymark, J.
2013-07-01
ANSI/ASHRAE Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs applies the IEA BESTEST building thermal fabric test cases and example simulation results originally published in 1995. These software accuracy test cases and their example simulation results, which comprise the first test suite adapted for the initial 2001 version of Standard 140, are approaching their 20th anniversary. In response to the evolution of the state of the art in building thermal fabric modeling since the test cases and example simulation results were developed, work is commencing to update the normative test specification and themore » informative example results.« less
Valente, Marta Sofia; Pedro, Paulo; Alonso, M Carmen; Borrego, Juan J; Dionísio, Lídia
2010-03-01
Monitoring the microbiological quality of water used for recreational activities is very important to human public health. Although the sanitary quality of recreational marine waters could be evaluated by standard methods, they are time-consuming and need confirmation. For these reasons, faster and more sensitive methods, such as the defined substrate-based technology, have been developed. In the present work, we have compared the standard method of membrane filtration using Tergitol-TTC agar for total coliforms and Escherichia coli, and Slanetz and Bartley agar for enterococci, and the IDEXX defined substrate technology for these faecal pollution indicators to determine the microbiological quality of natural recreational waters. ISO 17994:2004 standard was used to compare these methods. The IDEXX for total coliforms and E. coli, Colilert, showed higher values than those obtained by the standard method. Enterolert test, for the enumeration of enterococci, showed lower values when compared with the standard method. It may be concluded that more studies to evaluate the precision and accuracy of the rapid tests are required in order to apply them for routine monitoring of marine and freshwater recreational bathing areas. The main advantages of these methods are that they are more specific, feasible and simpler than the standard methodology.
40 CFR 63.344 - Performance test requirements and test methods.
Code of Federal Regulations, 2014 CFR
2014-07-01
... blanket type fume suppressants are used to control chromium emissions from a hard chromium electroplating... National Emission Standards for Chromium Emissions From Hard and Decorative Chromium Electroplating and Chromium Anodizing Tanks § 63.344 Performance test requirements and test methods. (a) Performance test...
40 CFR 63.344 - Performance test requirements and test methods.
Code of Federal Regulations, 2012 CFR
2012-07-01
... blanket type fume suppressants are used to control chromium emissions from a hard chromium electroplating... National Emission Standards for Chromium Emissions From Hard and Decorative Chromium Electroplating and Chromium Anodizing Tanks § 63.344 Performance test requirements and test methods. (a) Performance test...
40 CFR 63.344 - Performance test requirements and test methods.
Code of Federal Regulations, 2013 CFR
2013-07-01
... blanket type fume suppressants are used to control chromium emissions from a hard chromium electroplating... National Emission Standards for Chromium Emissions From Hard and Decorative Chromium Electroplating and Chromium Anodizing Tanks § 63.344 Performance test requirements and test methods. (a) Performance test...
Ghannoum, M. A.; Arthington-Skaggs, B.; Chaturvedi, V.; Espinel-Ingroff, A.; Pfaller, M. A.; Rennie, R.; Rinaldi, M. G.; Walsh, T. J.
2006-01-01
The Clinical and Laboratory Standards Institute (CLSI; formerly National Committee for Clinical Laboratory Standards, or NCCLS) M38-A standard for the susceptibility testing of filamentous fungi does not specifically address the testing of dermatophytes. In 2003, a multicenter study investigated the reproducibility of the microdilution method developed at the Center for Medical Mycology, Cleveland, Ohio, for testing the susceptibility of dermatophytes. Data from that study supported the introduction of this method for testing dermatophytes in the future version of the CLSI M38-A standard. In order for the method to be accepted by CLSI, appropriate quality control isolates needed to be identified. To that end, an interlaboratory study, involving the original six laboratories plus two additional sites, was conducted to evaluate potential candidates for quality control isolates. These candidate strains included five Trichophyton rubrum strains known to have elevated MICs to terbinafine and five Trichophyton mentagrophytes strains. Antifungal agents tested included ciclopirox, fluconazole, griseofulvin, itraconazole, posaconazole, terbinafine, and voriconazole. Based on the data generated, two quality control isolates, one T. rubrum isolate and one T. mentagrophytes isolate, were identified and submitted to the American Type Culture Collection (ATCC) for inclusion as reference strains. Ranges encompassing 95.2 to 97.9% of all data points for all seven drugs were established. PMID:17050812
Standard Test Methods for Textile Composites
NASA Technical Reports Server (NTRS)
Masters, John E.; Portanova, Marc A.
1996-01-01
Standard testing methods for composite laminates reinforced with continuous networks of braided, woven, or stitched fibers have been evaluated. The microstructure of these textile' composite materials differs significantly from that of tape laminates. Consequently, specimen dimensions and loading methods developed for tape type composites may not be applicable to textile composites. To this end, a series of evaluations were made comparing testing practices currently used in the composite industry. Information was gathered from a variety of sources and analyzed to establish a series of recommended test methods for textile composites. The current practices established for laminated composite materials by ASTM and the MIL-HDBK-17 Committee were considered. This document provides recommended test methods for determining both in-plane and out-of-plane properties. Specifically, test methods are suggested for: unnotched tension and compression; open and filled hole tension; open hole compression; bolt bearing; and interlaminar tension. A detailed description of the material architectures evaluated is also provided, as is a recommended instrumentation practice.
77 FR 73345 - Safety Standard for Bedside Sleepers
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-10
... product-related issues, such as non- levelness of the product (two reports), instability of leg extensions...) Segmented Mattress Flatness Requirement and Test Method; (2) Removable Bassinet Bed Stability; and (3) Stability Test Dummy. Because bedside sleepers are already required to be tested to the bassinet standard...
Madej, Roberta M.; Davis, Jack; Holden, Marcia J.; Kwang, Stan; Labourier, Emmanuel; Schneider, George J.
2010-01-01
The utility of quantitative molecular diagnostics for patient management depends on the ability to relate patient results to prior results or to absolute values in clinical practice guidelines. To do this, those results need to be comparable across time and methods, either by producing the same value across methods and test versions or by using reliable and stable conversions. Universally available standards and reference materials specific to quantitative molecular technologies are critical to this process but are few in number. This review describes recent history in the establishment of international standards for nucleic acid test development, organizations involved in current efforts, and future issues and initiatives. PMID:20075208
Development of delineator testing standard.
DOT National Transportation Integrated Search
2015-02-01
The objective of this project was to develop a new test method for evaluating the impact performance : of delineators for given applications. The researchers focused on developing a test method that was : reproducible and attempted to reproduce failu...
46 CFR 160.171-3 - Incorporation by reference.
Code of Federal Regulations, 2010 CFR
2010-10-01
... (b) of this section, notice of change must be published in the Federal Register and the material made..., Standard Test Method for Initial Tear Resistance of Plastic Film and Sheeting—160.171-17 Federal Standards... Resistance of Cloth, Oscillatory Cylinder (Wyzenbeek) Method, dated July 9, 1971. Federal Standard No. 751a...
Karakuła-Juchnowicz, Hanna; Stecka, Mariola
2017-08-29
In view of unavailability in Poland of the standardized methods to measure PIQ, the aim of the work was to develop a Polish test to assess the premorbid level of intelligence - PART(Polish AdultReading Test) and to measureits psychometric properties, such as validity, reliability as well as standardization in the group of schizophrenia patients. The principles of PART construction were based on the idea of popular worldwide National Adult Reading Test by Hazel Nelson. The research comprised a group of 122 subjects (65 schizophrenia patients and 57 healthy people), aged 18-60 years, matched for age and gender. PART appears to be a method with high internal consistency and reliability measured by test-retest, inter-rater reliability, and the method with acceptable diagnostic and prognostic validity. The standardized procedures of PART have been investigated and described. Considering the psychometric values of PART and a short time of its performance, the test may be a useful diagnostic instrument in the assessment of premorbid level of intelligence in a group of schizophrenic patients.
Flammability of gas mixtures. Part 1: fire potential.
Schröder, Volkmar; Molnarne, Maria
2005-05-20
International and European dangerous substances and dangerous goods regulations refer to the standard ISO 10156 (1996). This standard includes a test method and a calculation procedure for the determination of the flammability of gases and gas mixtures in air. The substance indices for the calculation, the so called "Tci values", which characterise the fire potential, are provided as well. These ISO Tci values are derived from explosion diagrams of older literature sources which do not take into account the test method and the test apparatus. However, since the explosion limits are influenced by apparatus parameters, the Tci values and lower explosion limits, given by the ISO tables, are inconsistent with those measured according to the test method of the same standard. In consequence, applying the ISO Tci values can result in wrong classifications. In this paper internationally accepted explosion limit test methods were evaluated and Tci values were derived from explosion diagrams. Therefore, an "open vessel" method with flame propagation criterion was favoured. These values were compared with the Tci values listed in ISO 10156. In most cases, significant deviations were found. A detailed study about the influence of inert gases on flammability is the objective of Part 2.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, D.; Wohlgemuth, J.; Gu, X.
2013-11-01
The curing of cross-linkable encapsulation is a critical consideration for photovoltaic (PV) modules manufactured using a lamination process. Concerns related to ethylene-co-vinyl acetate (EVA) include the quality (e.g., expiration and uniformity) of the films or completion (duration) of the cross-linking of the EVA within a laminator. Because these issues are important to both EVA and module manufacturers, an international standard has recently been proposed by the Encapsulation Task-Group within the Working Group 2 (WG2) of the International Electrotechnical Commission (IEC) Technical Committee 82 (TC82) for the quantification of the degree of cure for EVA encapsulation. The present draft of themore » standard calls for the use of differential scanning calorimetry (DSC) as the rapid, enabling secondary (test) method. Both the residual enthalpy- and melt/freeze-DSC methods are identified. The DSC methods are calibrated against the gel content test, the primary (reference) method. Aspects of other established methods, including indentation and rotor cure metering, were considered by the group. Key details of the test procedure will be described.« less
Yu, Chen; Zhang, Qian; Xu, Peng-Yao; Bai, Yin; Shen, Wen-Bin; Di, Bin; Su, Meng-Xiang
2018-01-01
Quantitative nuclear magnetic resonance (qNMR) is a well-established technique in quantitative analysis. We presented a validated 1 H-qNMR method for assay of octreotide acetate, a kind of cyclic octopeptide. Deuterium oxide was used to remove the undesired exchangeable peaks, which was referred to as proton exchange, in order to make the quantitative signals isolated in the crowded spectrum of the peptide and ensure precise quantitative analysis. Gemcitabine hydrochloride was chosen as the suitable internal standard. Experimental conditions, including relaxation delay time, the numbers of scans, and pulse angle, were optimized first. Then method validation was carried out in terms of selectivity, stability, linearity, precision, and robustness. The assay result was compared with that by means of high performance liquid chromatography, which is provided by Chinese Pharmacopoeia. The statistical F test, Student's t test, and nonparametric test at 95% confidence level indicate that there was no significant difference between these two methods. qNMR is a simple and accurate quantitative tool with no need for specific corresponding reference standards. It has the potential of the quantitative analysis of other peptide drugs and standardization of the corresponding reference standards. Copyright © 2017 John Wiley & Sons, Ltd.
40 CFR 63.786 - Test methods and procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 11 2014-07-01 2014-07-01 false Test methods and procedures. 63.786...) National Emission Standards for Shipbuilding and Ship Repair (Surface Coating) § 63.786 Test methods and procedures. (a) For the compliance procedures described in § 63.785(c) (1) through (c)(3), Method 24 of 40...
40 CFR 63.905 - Test methods and procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 11 2014-07-01 2014-07-01 false Test methods and procedures. 63.905...) National Emission Standards for Tanks-Level 1 § 63.905 Test methods and procedures. (a) Procedure for... be conducted in accordance with the procedures specified in Method 21 of 40 CFR part 60, appendix A...
40 CFR 63.1046 - Test methods and procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 11 2014-07-01 2014-07-01 false Test methods and procedures. 63.1046...) National Emission Standards for Oil-Water Separators and Organic-Water Separators § 63.1046 Test methods... Method 21 of 40 CFR part 60, appendix A. Each potential leak interface (i.e., a location where organic...
Nonvolatile, semivolatile, or volatile: redefining volatile for volatile organic compounds.
Võ, Uyên-Uyén T; Morris, Michael P
2014-06-01
Although widely used in air quality regulatory frameworks, the term "volatile organic compound" (VOC) is poorly defined. Numerous standardized tests are currently used in regulations to determine VOC content (and thus volatility), but in many cases the tests do not agree with each other, nor do they always accurately represent actual evaporation rates under ambient conditions. The parameters (time, temperature, reference material, column polarity, etc.) used in the definitions and the associated test methods were created without a significant evaluation of volatilization characteristics in real world settings. Not only do these differences lead to varying VOC content results, but occasionally they conflict with one another. An ambient evaporation study of selected compounds and a few formulated products was conducted and the results were compared to several current VOC test methodologies: SCAQMD Method 313 (M313), ASTM Standard Test Method E 1868-10 (E1868), and US. EPA Reference Method 24 (M24). The ambient evaporation study showed a definite distinction between nonvolatile, semivolatile, and volatile compounds. Some low vapor pressure (LVP) solvents, currently considered exempt as VOCs by some methods, volatilize at ambient conditions nearly as rapidly as the traditional high-volatility solvents they are meant to replace. Conversely, bio-based and heavy hydrocarbons did not readily volatilize, though they often are calculated as VOCs in some traditional test methods. The study suggests that regulatory standards should be reevaluated to more accurately reflect real-world emission from the use of VOC containing products. The definition of VOC in current test methods may lead to regulations that exclude otherwise viable alternatives or allow substitutions of chemicals that may limit the environmental benefits sought in the regulation. A study was conducted to examine volatility of several compounds and a few formulated products under several current VOC test methodologies and ambient evaporation. This paper provides ample evidence to warrant a reevaluation of regulatory standards and provides a framework for progressive developments based on reasonable and scientifically justifiable definitions of VOCs.
Scale factor measure method without turntable for angular rate gyroscope
NASA Astrophysics Data System (ADS)
Qi, Fangyi; Han, Xuefei; Yao, Yanqing; Xiong, Yuting; Huang, Yuqiong; Wang, Hua
2018-03-01
In this paper, a scale factor test method without turntable is originally designed for the angular rate gyroscope. A test system which consists of test device, data acquisition circuit and data processing software based on Labview platform is designed. Taking advantage of gyroscope's sensitivity of angular rate, a gyroscope with known scale factor, serves as a standard gyroscope. The standard gyroscope is installed on the test device together with a measured gyroscope. By shaking the test device around its edge which is parallel to the input axis of gyroscope, the scale factor of the measured gyroscope can be obtained in real time by the data processing software. This test method is fast. It helps test system miniaturized, easy to carry or move. Measure quarts MEMS gyroscope's scale factor multi-times by this method, the difference is less than 0.2%. Compare with testing by turntable, the scale factor difference is less than 1%. The accuracy and repeatability of the test system seems good.
Realistic metrics and methods for testing household biomass cookstoves are required to develop standards needed by international policy makers, donors, and investors. Application of consistent test practices allows emissions and energy efficiency performance to be benchmarked and...
Laurin, E; Thakur, K K; Gardner, I A; Hick, P; Moody, N J G; Crane, M S J; Ernst, I
2018-05-01
Design and reporting quality of diagnostic accuracy studies (DAS) are important metrics for assessing utility of tests used in animal and human health. Following standards for designing DAS will assist in appropriate test selection for specific testing purposes and minimize the risk of reporting biased sensitivity and specificity estimates. To examine the benefits of recommending standards, design information from published DAS literature was assessed for 10 finfish, seven mollusc, nine crustacean and two amphibian diseases listed in the 2017 OIE Manual of Diagnostic Tests for Aquatic Animals. Of the 56 DAS identified, 41 were based on field testing, eight on experimental challenge studies and seven on both. Also, we adapted human and terrestrial-animal standards and guidelines for DAS structure for use in aquatic animal diagnostic research. Through this process, we identified and addressed important metrics for consideration at the design phase: study purpose, targeted disease state, selection of appropriate samples and specimens, laboratory analytical methods, statistical methods and data interpretation. These recommended design standards for DAS are presented as a checklist including risk-of-failure points and actions to mitigate bias at each critical step. Adherence to standards when designing DAS will also facilitate future systematic review and meta-analyses of DAS research literature. © 2018 John Wiley & Sons Ltd.
Development of a Contact Permeation Test Fixture and Method
2013-04-01
direct contact with the skin, indicates the need for a quantitative contact test method. Comparison tests were conducted with VX on a standardized...Guide for the Care and Use of Laboratory Animals (8th ed.; National Research Council: Washington, DC, 2011). This test was also performed in...1 1.2 Development of a Contact-Based Permeation Test Method ........................................ 1 2. EXPERIMENTAL PROCEDURES
A comparative appraisal of two equivalence tests for multiple standardized effects.
Shieh, Gwowen
2016-04-01
Equivalence testing is recommended as a better alternative to the traditional difference-based methods for demonstrating the comparability of two or more treatment effects. Although equivalent tests of two groups are widely discussed, the natural extensions for assessing equivalence between several groups have not been well examined. This article provides a detailed and schematic comparison of the ANOVA F and the studentized range tests for evaluating the comparability of several standardized effects. Power and sample size appraisals of the two grossly distinct approaches are conducted in terms of a constraint on the range of the standardized means when the standard deviation of the standardized means is fixed. Although neither method is uniformly more powerful, the studentized range test has a clear advantage in sample size requirements necessary to achieve a given power when the underlying effect configurations are close to the priori minimum difference for determining equivalence. For actual application of equivalence tests and advance planning of equivalence studies, both SAS and R computer codes are available as supplementary files to implement the calculations of critical values, p-values, power levels, and sample sizes. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Olson, S. L.; Beeson, H. D.; Haas, J. P.; Baas, J. S.
2004-01-01
The objective of this research is to modify the well-instrumented standard cone configuration to provide a reproducible bench-scale test environment that simulates the buoyant or ventilation flow that would be generated by or around a burning surface in a spacecraft or extraterrestrial gravity level. We will then develop a standard test method with pass-fail criteria for future use in spacecraft materials flammability screening. (For example, dripping of molten material will be an automatic fail.)
National Unmanned Aerial System Standardized Performance Testing and Rating (NUSTAR)
NASA Technical Reports Server (NTRS)
Kopardekar, Parimal
2016-01-01
The overall objective of the NUSTAR Capability is to offer standardized tests and scenario conditions to assess performance of the UAS. The following are goals of the NU-STAR: 1. Create a prototype standardized tests and scenarios that vehicles can be tested against. 2. Identify key performance parameters of all UAS and their standardized measurement strategy. 3. Develop standardized performance reporting method (e.g., consumer report style) to assist prospective buyers. 4. Identify key performance metrics that could be used by judged towards overall safety of the UAS and operations. 5. If vehicle certification standard is made by a regulatory agency, the performance of individual UAS could be compared against the minimum requirement (e.g., sense and avoid detection time, stopping distance, kinetic energy, etc.).
40 CFR 63.1546 - Performance testing.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 13 2012-07-01 2012-07-01 false Performance testing. 63.1546 Section... Emission Standards for Hazardous Air Pollutants for Primary Lead Smelting § 63.1546 Performance testing. (a... performance test shall consist of at least three runs. For each test run with Method 12 or Method 29, the...
Status of Photovoltaic Calibration and Measurement Standards
NASA Technical Reports Server (NTRS)
Baraona, Cosmo; Bailey, Sheila; Curtis, Henry; Brinker, David; Jenkins, Phillip; Scheiman, David
2001-01-01
The 7th International Workshop on Space Solar Cell Calibration and Measurement was held on September 25-27, 2000 in Girdwood, Alaska. Representatives from eight countries discussed international standards for single and multijunction solar cell measurement and calibration methods, round robin intercomparisons, and irradiation test methods for space solar cells. Progress toward adoption of an ISO standard on single junction cells was made. Agreement was reached to begin work on new standards for multijunction cells and irradiation testing. Progress on present single junction round robin measurements was discussed and future multijunction round robins were planned. The next workshop will be held in Germany in October 2001.
Alternative Confidence Interval Methods Used in the Diagnostic Accuracy Studies
Gülhan, Orekıcı Temel
2016-01-01
Background/Aim. It is necessary to decide whether the newly improved methods are better than the standard or reference test or not. To decide whether the new diagnostics test is better than the gold standard test/imperfect standard test, the differences of estimated sensitivity/specificity are calculated with the help of information obtained from samples. However, to generalize this value to the population, it should be given with the confidence intervals. The aim of this study is to evaluate the confidence interval methods developed for the differences between the two dependent sensitivity/specificity values on a clinical application. Materials and Methods. In this study, confidence interval methods like Asymptotic Intervals, Conditional Intervals, Unconditional Interval, Score Intervals, and Nonparametric Methods Based on Relative Effects Intervals are used. Besides, as clinical application, data used in diagnostics study by Dickel et al. (2010) has been taken as a sample. Results. The results belonging to the alternative confidence interval methods for Nickel Sulfate, Potassium Dichromate, and Lanolin Alcohol are given as a table. Conclusion. While preferring the confidence interval methods, the researchers have to consider whether the case to be compared is single ratio or dependent binary ratio differences, the correlation coefficient between the rates in two dependent ratios and the sample sizes. PMID:27478491
Alternative Confidence Interval Methods Used in the Diagnostic Accuracy Studies.
Erdoğan, Semra; Gülhan, Orekıcı Temel
2016-01-01
Background/Aim. It is necessary to decide whether the newly improved methods are better than the standard or reference test or not. To decide whether the new diagnostics test is better than the gold standard test/imperfect standard test, the differences of estimated sensitivity/specificity are calculated with the help of information obtained from samples. However, to generalize this value to the population, it should be given with the confidence intervals. The aim of this study is to evaluate the confidence interval methods developed for the differences between the two dependent sensitivity/specificity values on a clinical application. Materials and Methods. In this study, confidence interval methods like Asymptotic Intervals, Conditional Intervals, Unconditional Interval, Score Intervals, and Nonparametric Methods Based on Relative Effects Intervals are used. Besides, as clinical application, data used in diagnostics study by Dickel et al. (2010) has been taken as a sample. Results. The results belonging to the alternative confidence interval methods for Nickel Sulfate, Potassium Dichromate, and Lanolin Alcohol are given as a table. Conclusion. While preferring the confidence interval methods, the researchers have to consider whether the case to be compared is single ratio or dependent binary ratio differences, the correlation coefficient between the rates in two dependent ratios and the sample sizes.
NASA Astrophysics Data System (ADS)
Sperling, A.; Meyer, M.; Pendsa, S.; Jordan, W.; Revtova, E.; Poikonen, T.; Renoux, D.; Blattner, P.
2018-04-01
Proper characterization of test setups used in industry for testing and traceable measurement of lighting devices by the substitution method is an important task. According to new standards for testing LED lamps, luminaires and modules, uncertainty budgets are requested because in many cases the properties of the device under test differ from the transfer standard used, which may cause significant errors, for example if a LED-based lamp is tested or calibrated in an integrating sphere which was calibrated with a tungsten lamp. This paper introduces a multiple transfer standard, which was designed not only to transfer a single calibration value (e.g. luminous flux) but also to characterize test setups used for LED measurements with additional provided and calibrated output features to enable the application of the new standards.
40 CFR 80.8 - Sampling methods for gasoline and diesel fuel.
Code of Federal Regulations, 2010 CFR
2010-07-01
... applicable procedures specified in American Society for Testing and Materials (ASTM) method D 4057-95(2000... applicable procedures specified in ASTM method D 4177-95(2000), entitled “Standard Practice for Automatic... applicable procedures in ASTM method D 5842-95(2000), entitled “Standard Practice for Sampling and Handling...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Prokofiev, I.; Wiencek, T.; McGann, D.
1997-10-07
Powder metallurgy dispersions of uranium alloys and silicides in an aluminum matrix have been developed by the RERTR program as a new generation of proliferation-resistant fuels. Testing is done with miniplate-type fuel plates to simulate standard fuel with cladding and matrix in plate-type configurations. In order to seal the dispersion fuel plates, a diffusion bond must exist between the aluminum coverplates surrounding the fuel meat. Four different variations in the standard method for roll-bonding 6061 aluminum were studied. They included mechanical cleaning, addition of a getter material, modifications to the standard chemical etching, and welding methods. Aluminum test pieces weremore » subjected to a bend test after each rolling pass. Results, based on 400 samples, indicate that at least a 70% reduction in thickness is required to produce a diffusion bond using the standard rollbonding method versus a 60% reduction using the Type II method in which the assembly was welded 100% and contained open 9mm holes at frame corners.« less
Code of Federal Regulations, 2012 CFR
2012-01-01
... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Test methods. 1213.4 Section 1213.4 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS SAFETY STANDARD FOR ENTRAPMENT HAZARDS IN BUNK BEDS § 1213.4 Test methods. (a) Guardrails (see § 1213.3(a)(6...
Code of Federal Regulations, 2011 CFR
2011-01-01
... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Test methods. 1213.4 Section 1213.4 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS SAFETY STANDARD FOR ENTRAPMENT HAZARDS IN BUNK BEDS § 1213.4 Test methods. (a) Guardrails (see § 1213.3(a)(6...
Code of Federal Regulations, 2010 CFR
2010-01-01
... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Test methods. 1213.4 Section 1213.4 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS SAFETY STANDARD FOR ENTRAPMENT HAZARDS IN BUNK BEDS § 1213.4 Test methods. (a) Guardrails (see § 1213.3(a)(6...
Code of Federal Regulations, 2014 CFR
2014-01-01
... 16 Commercial Practices 2 2014-01-01 2014-01-01 false Test methods. 1213.4 Section 1213.4 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS SAFETY STANDARD FOR ENTRAPMENT HAZARDS IN BUNK BEDS § 1213.4 Test methods. (a) Guardrails (see § 1213.3(a)(6...
40 CFR 63.750 - Test methods and procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 10 2011-07-01 2011-07-01 false Test methods and procedures. 63.750...) National Emission Standards for Aerospace Manufacturing and Rework Facilities § 63.750 Test methods and... period as part of an ambient ozone control program. (1)(i) Determine the total organic HAP weight...
40 CFR 63.750 - Test methods and procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 11 2013-07-01 2013-07-01 false Test methods and procedures. 63.750...) National Emission Standards for Aerospace Manufacturing and Rework Facilities § 63.750 Test methods and... period as part of an ambient ozone control program. (1)(i) Determine the total organic HAP weight...
40 CFR 63.750 - Test methods and procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 11 2012-07-01 2012-07-01 false Test methods and procedures. 63.750...) National Emission Standards for Aerospace Manufacturing and Rework Facilities § 63.750 Test methods and... period as part of an ambient ozone control program. (1)(i) Determine the total organic HAP weight...
40 CFR 63.750 - Test methods and procedures.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Test methods and procedures. 63.750...) National Emission Standards for Aerospace Manufacturing and Rework Facilities § 63.750 Test methods and... period as part of an ambient ozone control program. (1)(i) Determine the total organic HAP weight...
ERIC Educational Resources Information Center
Davis, Caroline; Cowles, Michael
1989-01-01
Computerized and paper-and-pencil versions of four standard personality inventories administered to 147 undergraduates were compared for: (1) test-retest reliability; (2) scores; (3) trait anxiety; (4) interaction between method and social desirability; and (5) preferences concerning method of testing. Doubts concerning the efficacy of…
7 CFR 28.179 - Methods of cotton classification and comparison.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 2 2013-01-01 2013-01-01 false Methods of cotton classification and comparison. 28... STANDARD CONTAINER REGULATIONS COTTON CLASSING, TESTING, AND STANDARDS Classification for Foreign Growth Cotton § 28.179 Methods of cotton classification and comparison. The classification of samples from...
7 CFR 28.179 - Methods of cotton classification and comparison.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 2 2010-01-01 2010-01-01 false Methods of cotton classification and comparison. 28... STANDARD CONTAINER REGULATIONS COTTON CLASSING, TESTING, AND STANDARDS Classification for Foreign Growth Cotton § 28.179 Methods of cotton classification and comparison. The classification of samples from...
7 CFR 28.179 - Methods of cotton classification and comparison.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 2 2012-01-01 2012-01-01 false Methods of cotton classification and comparison. 28... STANDARD CONTAINER REGULATIONS COTTON CLASSING, TESTING, AND STANDARDS Classification for Foreign Growth Cotton § 28.179 Methods of cotton classification and comparison. The classification of samples from...
7 CFR 28.179 - Methods of cotton classification and comparison.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 2 2011-01-01 2011-01-01 false Methods of cotton classification and comparison. 28... STANDARD CONTAINER REGULATIONS COTTON CLASSING, TESTING, AND STANDARDS Classification for Foreign Growth Cotton § 28.179 Methods of cotton classification and comparison. The classification of samples from...
7 CFR 28.179 - Methods of cotton classification and comparison.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 2 2014-01-01 2014-01-01 false Methods of cotton classification and comparison. 28... STANDARD CONTAINER REGULATIONS COTTON CLASSING, TESTING, AND STANDARDS Classification for Foreign Growth Cotton § 28.179 Methods of cotton classification and comparison. The classification of samples from...
Applications of Automation Methods for Nonlinear Fracture Test Analysis
NASA Technical Reports Server (NTRS)
Allen, Phillip A.; Wells, Douglas N.
2013-01-01
As fracture mechanics material testing evolves, the governing test standards continue to be refined to better reflect the latest understanding of the physics of the fracture processes involved. The traditional format of ASTM fracture testing standards, utilizing equations expressed directly in the text of the standard to assess the experimental result, is self-limiting in the complexity that can be reasonably captured. The use of automated analysis techniques to draw upon a rich, detailed solution database for assessing fracture mechanics tests provides a foundation for a new approach to testing standards that enables routine users to obtain highly reliable assessments of tests involving complex, non-linear fracture behavior. Herein, the case for automating the analysis of tests of surface cracks in tension in the elastic-plastic regime is utilized as an example of how such a database can be generated and implemented for use in the ASTM standards framework. The presented approach forms a bridge between the equation-based fracture testing standards of today and the next generation of standards solving complex problems through analysis automation.
Antianaerobic Antimicrobials: Spectrum and Susceptibility Testing
Wexler, Hannah M.; Goldstein, Ellie J. C.
2013-01-01
SUMMARY Susceptibility testing of anaerobic bacteria recovered from selected cases can influence the choice of antimicrobial therapy. The Clinical and Laboratory Standards Institute (CLSI) has standardized many laboratory procedures, including anaerobic susceptibility testing (AST), and has published documents for AST. The standardization of testing methods by the CLSI allows comparisons of resistance trends among various laboratories. Susceptibility testing should be performed on organisms recovered from sterile body sites, those that are isolated in pure culture, or those that are clinically important and have variable or unique susceptibility patterns. Organisms that should be considered for individual isolate testing include highly virulent pathogens for which susceptibility cannot be predicted, such as Bacteroides, Prevotella, Fusobacterium, and Clostridium spp.; Bilophila wadsworthia; and Sutterella wadsworthensis. This review describes the current methods for AST in research and reference laboratories. These methods include the use of agar dilution, broth microdilution, Etest, and the spiral gradient endpoint system. The antimicrobials potentially effective against anaerobic bacteria include beta-lactams, combinations of beta-lactams and beta-lactamase inhibitors, metronidazole, chloramphenicol, clindamycin, macrolides, tetracyclines, and fluoroquinolones. The spectrum of efficacy, antimicrobial resistance mechanisms, and resistance patterns against these agents are described. PMID:23824372
ERIC Educational Resources Information Center
Ji, Chang; Boisvert, Susanne M.; Arida, Ann-Marie C.; Day, Shannon E.
2008-01-01
An internal standard method applicable to undergraduate instrumental analysis or environmental chemistry laboratory has been designed and tested to determine the Henry's law constants for a series of alkyl nitriles. In this method, a mixture of the analytes and an internal standard is prepared and used to make a standard solution (organic solvent)…
A studentized permutation test for three-arm trials in the 'gold standard' design.
Mütze, Tobias; Konietschke, Frank; Munk, Axel; Friede, Tim
2017-03-15
The 'gold standard' design for three-arm trials refers to trials with an active control and a placebo control in addition to the experimental treatment group. This trial design is recommended when being ethically justifiable and it allows the simultaneous comparison of experimental treatment, active control, and placebo. Parametric testing methods have been studied plentifully over the past years. However, these methods often tend to be liberal or conservative when distributional assumptions are not met particularly with small sample sizes. In this article, we introduce a studentized permutation test for testing non-inferiority and superiority of the experimental treatment compared with the active control in three-arm trials in the 'gold standard' design. The performance of the studentized permutation test for finite sample sizes is assessed in a Monte Carlo simulation study under various parameter constellations. Emphasis is put on whether the studentized permutation test meets the target significance level. For comparison purposes, commonly used Wald-type tests, which do not make any distributional assumptions, are included in the simulation study. The simulation study shows that the presented studentized permutation test for assessing non-inferiority in three-arm trials in the 'gold standard' design outperforms its competitors, for instance the test based on a quasi-Poisson model, for count data. The methods discussed in this paper are implemented in the R package ThreeArmedTrials which is available on the comprehensive R archive network (CRAN). Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Buzzi, Marina; Guarino, Anna; Gatto, Claudio; Manara, Sabrina; Dainese, Luca; Polvani, Gianluca; Tóthová, Jana D'Amato
2014-01-01
We investigated the presence of antibiotics in cryopreserved cardiovascular tissues and cryopreservation media, after tissue decontamination with antibiotic cocktails, and the impact of antibiotic residues on standard tissue bank microbiological analyses. Sixteen cardiovascular tissues were decontaminated with bank-prepared cocktails and cryopreserved by two different tissue banks according to their standard operating procedures. Before and after decontamination, samples underwent microbiological analysis by standard tissue bank methods. Cryopreserved samples were tested again with and without the removal of antibiotic residues using a RESEP tube, after thawing. Presence of antibiotics in tissue homogenates and processing liquids was determined by a modified agar diffusion test. All cryopreserved tissue homogenates and cryopreservation media induced important inhibition zones on both Staphylococcus aureus- and Pseudomonas aeruginosa-seeded plates, immediately after thawing and at the end of the sterility test. The RESEP tube treatment markedly reduced or totally eliminated the antimicrobial activity of tested tissues and media. Based on standard tissue bank analysis, 50% of tissues were found positive for bacteria and/or fungi, before decontamination and 2 out of 16 tested samples (13%) still contained microorganisms after decontamination. After thawing, none of the 16 cryopreserved samples resulted positive with direct inoculum method. When the same samples were tested after removal of antibiotic residues, 8 out of 16 (50%) were contaminated. Antibiotic residues present in tissue allografts and processing liquids after decontamination may mask microbial contamination during microbiological analysis performed with standard tissue bank methods, thus resulting in false negatives.
Gatto, Claudio; Manara, Sabrina; Dainese, Luca; Polvani, Gianluca; Tóthová, Jana D'Amato
2014-01-01
We investigated the presence of antibiotics in cryopreserved cardiovascular tissues and cryopreservation media, after tissue decontamination with antibiotic cocktails, and the impact of antibiotic residues on standard tissue bank microbiological analyses. Sixteen cardiovascular tissues were decontaminated with bank-prepared cocktails and cryopreserved by two different tissue banks according to their standard operating procedures. Before and after decontamination, samples underwent microbiological analysis by standard tissue bank methods. Cryopreserved samples were tested again with and without the removal of antibiotic residues using a RESEP tube, after thawing. Presence of antibiotics in tissue homogenates and processing liquids was determined by a modified agar diffusion test. All cryopreserved tissue homogenates and cryopreservation media induced important inhibition zones on both Staphylococcus aureus- and Pseudomonas aeruginosa-seeded plates, immediately after thawing and at the end of the sterility test. The RESEP tube treatment markedly reduced or totally eliminated the antimicrobial activity of tested tissues and media. Based on standard tissue bank analysis, 50% of tissues were found positive for bacteria and/or fungi, before decontamination and 2 out of 16 tested samples (13%) still contained microorganisms after decontamination. After thawing, none of the 16 cryopreserved samples resulted positive with direct inoculum method. When the same samples were tested after removal of antibiotic residues, 8 out of 16 (50%) were contaminated. Antibiotic residues present in tissue allografts and processing liquids after decontamination may mask microbial contamination during microbiological analysis performed with standard tissue bank methods, thus resulting in false negatives. PMID:25397402
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tenent, Robert C.
2017-12-06
NREL will conduct durability testing of Sage Electrochromics dynamic windows products using American Society for Testing and Materials (ASTM) standard methods and drive parameters as defined by Sage. Window units will be tested and standard analysis performed. Data will be summarized and reported back to Sage at the end of the testing period.
ERIC Educational Resources Information Center
Hill, James E.; And Others
A study has been made at the National Bureau of Standards of the different techniques that are or could be used for testing solar collectors and thermal storage devices that are used in solar heating and cooling systems. This report reviews the various testing methods and outlines a recommended test procedure, including apparatus and…
DOT National Transportation Integrated Search
2011-10-30
Main aim of this project was to evaluate alternate standard test methods for stress corrosion cracking (SCC) and compare them with the results from slow strain rate test (SSRT) results under equivalent environmental conditions. Other important aim of...
Test Anxiety and High-Stakes Test Performance between School Settings: Implications for Educators
ERIC Educational Resources Information Center
von der Embse, Nathaniel; Hasson, Ramzi
2012-01-01
With the enactment of standards-based accountability in education, high-stakes tests have become the dominant method for measuring school effectiveness and student achievement. Schools and educators are under increasing pressure to meet achievement standards. However, there are variables which may interfere with the authentic measurement of…
Grid Standards and Codes | Grid Modernization | NREL
simulations that take advantage of advanced concepts such as hardware-in-the-loop testing. Such methods of methods and solutions. Projects Accelerating Systems Integration Standards Sharp increases in goal of this project is to develop streamlined and accurate methods for New York utilities to determine
Standard test method for grindability of coal by the hardgrove-machine method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1975-01-01
This method is used to determine the relative grindability or ease of pulverization of coals in comparison with coals chosen as standards. A prepared sample receives a definite amount of grinding energy in a miniature pulverizer, and the change in size consist is determined by sieving.
Ye, Xin; Garikapati, Venu M.; You, Daehyun; ...
2017-11-08
Most multinomial choice models (e.g., the multinomial logit model) adopted in practice assume an extreme-value Gumbel distribution for the random components (error terms) of utility functions. This distributional assumption offers a closed-form likelihood expression when the utility maximization principle is applied to model choice behaviors. As a result, model coefficients can be easily estimated using the standard maximum likelihood estimation method. However, maximum likelihood estimators are consistent and efficient only if distributional assumptions on the random error terms are valid. It is therefore critical to test the validity of underlying distributional assumptions on the error terms that form the basismore » of parameter estimation and policy evaluation. In this paper, a practical yet statistically rigorous method is proposed to test the validity of the distributional assumption on the random components of utility functions in both the multinomial logit (MNL) model and multiple discrete-continuous extreme value (MDCEV) model. Based on a semi-nonparametric approach, a closed-form likelihood function that nests the MNL or MDCEV model being tested is derived. The proposed method allows traditional likelihood ratio tests to be used to test violations of the standard Gumbel distribution assumption. Simulation experiments are conducted to demonstrate that the proposed test yields acceptable Type-I and Type-II error probabilities at commonly available sample sizes. The test is then applied to three real-world discrete and discrete-continuous choice models. For all three models, the proposed test rejects the validity of the standard Gumbel distribution in most utility functions, calling for the development of robust choice models that overcome adverse effects of violations of distributional assumptions on the error terms in random utility functions.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ye, Xin; Garikapati, Venu M.; You, Daehyun
Most multinomial choice models (e.g., the multinomial logit model) adopted in practice assume an extreme-value Gumbel distribution for the random components (error terms) of utility functions. This distributional assumption offers a closed-form likelihood expression when the utility maximization principle is applied to model choice behaviors. As a result, model coefficients can be easily estimated using the standard maximum likelihood estimation method. However, maximum likelihood estimators are consistent and efficient only if distributional assumptions on the random error terms are valid. It is therefore critical to test the validity of underlying distributional assumptions on the error terms that form the basismore » of parameter estimation and policy evaluation. In this paper, a practical yet statistically rigorous method is proposed to test the validity of the distributional assumption on the random components of utility functions in both the multinomial logit (MNL) model and multiple discrete-continuous extreme value (MDCEV) model. Based on a semi-nonparametric approach, a closed-form likelihood function that nests the MNL or MDCEV model being tested is derived. The proposed method allows traditional likelihood ratio tests to be used to test violations of the standard Gumbel distribution assumption. Simulation experiments are conducted to demonstrate that the proposed test yields acceptable Type-I and Type-II error probabilities at commonly available sample sizes. The test is then applied to three real-world discrete and discrete-continuous choice models. For all three models, the proposed test rejects the validity of the standard Gumbel distribution in most utility functions, calling for the development of robust choice models that overcome adverse effects of violations of distributional assumptions on the error terms in random utility functions.« less
Dumont, J.N.; Bantle, J.A.; Linder, G.; ,
2003-01-01
The energy crisis of the 1970's and 1980's prompted the search for alternative sources of fuel. With development of alternate sources of energy, concerns for biological resources potentially adversely impacted by these alternative technologies also heightened. For example, few biological tests were available at the time to study toxic effects of effluents on surface waters likely to serve as receiving streams for energy-production facilities; hence, we began to use Xenopus laevis embryos as test organisms to examine potential toxic effects associated with these effluents upon entering aquatic systems. As studies focused on potential adverse effects on aquatic systems continued, a test procedure was developed that led to the initial standardization of FETAX. Other .than a limited number of aquatic toxicity tests that used fathead minnows and cold-water fishes such as rainbow trout, X. laevis represented the only other aquatic vertebrate test system readily available to evaluate complex effluents. With numerous laboratories collaborating, the test with X. laevis was refined, improved, and developed as ASTM E-1439, Standard Guide for the Conducting Frog Embryo Teratogenesis Assay-Xenopus (FETAX). Collabrative work in the 1990s yielded procedural enhancements, for example, development of standard test solutions and exposure methods to handle volatile organics and hydrophobic compounds. As part of the ASTM process, a collaborative interlaboratory study was performed to determine the repeatability and reliability of FETAX. Parallel to these efforts, methods were also developed to test sediments and soils, and in situ test methods were developed to address "lab-to-field extrapolation errors" that could influence the method's use in ecological risk assessments. Additionally, a metabolic activation system composed of rat liver microsomes was developed which made FETAX more relevant to mammalian studies.
Kondori, N; Svensson, E; Mattsby-Baltzer, I
2011-09-01
The use of anti-fungal agents has increased dramatically in recent years and new drugs have been developed. Several methods are available for determinations of their specific biological activities, i.e. the standard method for minimum inhibitory concentration-determination is described in M-38 [Clinical and Laboratory Standards Institute document M-38 (CLSI M-38)]. However, alternative methods, such as the E-test, are currently available in Mycology laboratories. The susceptibilities of clinical isolates of Aspergillus spp. (n = 29), Fusarium spp. (n = 5), zygomycetes (n = 21) and Schizophyllum (n = 1) were determined for itraconazole, voriconazole and posaconazole, using the CLSI M-38-A broth dilution method and also by the E-test. A good overall agreement (83.7%) between the two methods for all drugs and organisms was observed. Analyses of voriconazole showed a better agreement (93%) between the methods than posaconazole and itraconazole (85% and 74% respectively). Aspergillus spp. were the most susceptible fungi to the anti-fungal agents tested in this study. Posaconazole was the most active drug against filamentous fungi in vitro, followed by itraconazole and voriconazole. The latter (voriconazole) demonstrated no significant in vitro activity against zygomycetes. © 2010 Blackwell Verlag GmbH.
Code of Federal Regulations, 2010 CFR
2010-04-01
... particleboard is produced or surface-finished, whichever is later, the panels must be dead-stacked or air-tight... with the Standard Test Method for Determining Formaldehyde Levels from Wood Products Under Defined Test...
NASA Astrophysics Data System (ADS)
Loureiro, A. D.; Gomes, L. M.; Ventura, L.
2018-02-01
The international standard ISO 12312-1 proposes transmittance tests that quantify how dark sunglasses lenses are and whether or not they are suitable for driving. To perform these tests a spectrometer is required. In this study, we present and analyze theoretically an accurate alternative method for performing these measurements using simple components. Using three LEDs and a four-channel sensor we generated weighting functions similar to the standard ones for luminous and traffic lights transmittances. From 89 sunglasses lens spectroscopy data, we calculated luminous transmittance and signal detection quotients using our obtained weighting functions and the standard ones. Mean-difference Tukey plots were used to compare the results. All tested sunglasses lenses were classified in the right category and correctly as suitable or not for driving. The greatest absolute errors for luminous transmittance and red, yellow, green and blue signal detection quotients were 0.15%, 0.17, 0.06, 0.04 and 0.18, respectively. This method will be used in a device capable to perform transmittance tests (visible, traffic lights and ultraviolet (UV)) according to the standard. It is important to measure rightly luminous transmittance and relative visual attenuation quotients to report correctly whether or not sunglasses are suitable for driving. Moreover, standard UV requirements depend on luminous transmittance.
A novel method for direct solder bump pull testing using lead-free solders
NASA Astrophysics Data System (ADS)
Turner, Gregory Alan
This thesis focuses on the design, fabrication, and evaluation of a new method for testing the adhesion strength of lead-free solders, named the Isotraction Bump Pull method (IBP). In order to develop a direct solder joint-strength testing method that did not require customization for different solder types, bump sizes, specific equipment, or trial-and-error, a combination of two widely used and accepted standards was created. First, solder bumps were made from three types of lead free solder were generated on untreated copper PCB substrates using an in-house fabricated solder bump-on-demand generator, Following this, the newly developed method made use of a polymer epoxy to encapsulate the solder bumps that could then be tested under tension using a high precision universal vertical load machine. The tests produced repeatable and predictable results for each of the three alloys tested that were in agreement with the relative behavior of the same alloys using other testing methods in the literature. The median peak stress at failure for the three solders tested were 2020.52 psi, 940.57 psi, and 2781.0 psi, and were within one standard deviation of the of all data collected for each solder. The assumptions in this work that brittle fracture occurred through the Intermetallic Compound layer (IMC) were validated with the use of Energy-Dispersive X-Ray Spectrometry and high magnification of the fractured surface of both newly exposed sides of the test specimens. Following this, an examination of the process to apply the results from the tensile tests into standard material science equations for the fracture of the systems was performed..
NASA Technical Reports Server (NTRS)
Knox, R. J.
1978-01-01
Embryonic kidney cells were studied as a follow-up to the MA-011 Electrophoresis Technology Experiment which was conducted during the Apollo Soyuz Test Project (ASTP). The postflight analysis of the performance of the ASTP zone electrophoresis experiment involving embryonic kidney cells is reported. The feasibility of producing standard particles for electrophoresis was also studied. This work was undertaken in response to a need for standardization of methods for producing, calibrating, and storing electrophoretic particle standards which could be employed in performance tests of various types of electrophoresis equipment. Promising procedures were tested for their suitability in the production of standard test particles from red blood cells.
SHAW, Anugrah; COLEONE-CARVALHO, Ana Carla; HOLLINGSHURST, Julien; DRAPER, Michael; MACHADO NETO, Joaquim Gonçalves
2017-01-01
A collaborative approach, involving resources and expertise from several countries, was used to develop a test cell to measure cumulative permeation by a solid-state collection technique. The new technique was developed to measure the permeation of pesticide active ingredients and other chemicals with low vapor pressure that would otherwise be difficult to test via standard techniques. The development process is described and the results from the final chosen test method are reported. Inter-laboratory studies were conducted to further refine the new method and determine repeatability and reliability. The revised test method has been approved as a new ISO/EN standard to measure permeation of chemicals with low vapor pressure and/or solubility in water. PMID:29033403
40 CFR 63.1546 - Performance testing.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 13 2013-07-01 2012-07-01 true Performance testing. 63.1546 Section 63... Emission Standards for Hazardous Air Pollutants for Primary Lead Smelting § 63.1546 Performance testing. (a... performance test shall consist of at least three runs. For each test run with Method 12 or Method 29, the...
Hammond, M Elizabeth H; Barker, Peter; Taube, Sheila; Gutman, Steven
2003-06-01
A workshop was sponsored by the National Institute of Standards and Technology, the Cancer Diagnosis Program of the National Cancer Institute, the Food and Drug Administration, and the College of American Pathologists to address the need for a reference material for Her2 gene protein testing. It was agreed that such a standard was desirable and necessary to ensure the reliability of Her2 testing to qualify patients for trastuzumab therapy. Two standards consisting of well characterized cell lines will be produced, 1 that will be a National Institute of Standards and Technology-certifiable standard, and 1 that will be a commercially developed standard for use in all Her2 testing. It was also agreed that all Her2 testing must be performed on samples fixed only in 10% buffered formalin, as specified in the Food and Drug Administration-approved testing methods. Participants agreed to plan strategies to educate pathologists, clinicians, and laboratories about the need and use of such a standard. A National Committee for Clinical Laboratory Standards guideline for the use of the standard reference material will be created to facilitate this process.
40 CFR 63.7142 - What are the requirements for claiming area source status?
Code of Federal Regulations, 2013 CFR
2013-07-01
... test must be repeated. (v) The post-test analyte spike procedure of section 11.2.7 of ASTM Method D6735... (3) ASTM Method D6735-01, Standard Test Method for Measurement of Gaseous Chlorides and Fluorides...)(3)(i) through (vi) of this section are followed. (i) A test must include three or more runs in which...
40 CFR 63.7142 - What are the requirements for claiming area source status?
Code of Federal Regulations, 2011 CFR
2011-07-01
... test must be repeated. (v) The post-test analyte spike procedure of section 11.2.7 of ASTM Method D6735... (3) ASTM Method D6735-01, Standard Test Method for Measurement of Gaseous Chlorides and Fluorides...)(3)(i) through (vi) of this section are followed. (i) A test must include three or more runs in which...
40 CFR 63.7142 - What are the requirements for claiming area source status?
Code of Federal Regulations, 2012 CFR
2012-07-01
... test must be repeated. (v) The post-test analyte spike procedure of section 11.2.7 of ASTM Method D6735... (3) ASTM Method D6735-01, Standard Test Method for Measurement of Gaseous Chlorides and Fluorides...)(3)(i) through (vi) of this section are followed. (i) A test must include three or more runs in which...
40 CFR 63.7142 - What are the requirements for claiming area source status?
Code of Federal Regulations, 2010 CFR
2010-07-01
... test must be repeated. (v) The post-test analyte spike procedure of section 11.2.7 of ASTM Method D6735... (3) ASTM Method D6735-01, Standard Test Method for Measurement of Gaseous Chlorides and Fluorides...)(3)(i) through (vi) of this section are followed. (i) A test must include three or more runs in which...
40 CFR 63.7142 - What are the requirements for claiming area source status?
Code of Federal Regulations, 2014 CFR
2014-07-01
... test must be repeated. (v) The post-test analyte spike procedure of section 11.2.7 of ASTM Method D6735... (3) ASTM Method D6735-01, Standard Test Method for Measurement of Gaseous Chlorides and Fluorides...)(3)(i) through (vi) of this section are followed. (i) A test must include three or more runs in which...
Near-infrared fluorescence image quality test methods for standardized performance evaluation
NASA Astrophysics Data System (ADS)
Kanniyappan, Udayakumar; Wang, Bohan; Yang, Charles; Ghassemi, Pejhman; Wang, Quanzeng; Chen, Yu; Pfefer, Joshua
2017-03-01
Near-infrared fluorescence (NIRF) imaging has gained much attention as a clinical method for enhancing visualization of cancers, perfusion and biological structures in surgical applications where a fluorescent dye is monitored by an imaging system. In order to address the emerging need for standardization of this innovative technology, it is necessary to develop and validate test methods suitable for objective, quantitative assessment of device performance. Towards this goal, we develop target-based test methods and investigate best practices for key NIRF imaging system performance characteristics including spatial resolution, depth of field and sensitivity. Characterization of fluorescence properties was performed by generating excitation-emission matrix properties of indocyanine green and quantum dots in biological solutions and matrix materials. A turbid, fluorophore-doped target was used, along with a resolution target for assessing image sharpness. Multi-well plates filled with either liquid or solid targets were generated to explore best practices for evaluating detection sensitivity. Overall, our results demonstrate the utility of objective, quantitative, target-based testing approaches as well as the need to consider a wide range of factors in establishing standardized approaches for NIRF imaging system performance.
16 CFR § 1213.4 - Test methods.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 16 Commercial Practices 2 2013-01-01 2013-01-01 false Test methods. § 1213.4 Section § 1213.4 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS SAFETY STANDARD FOR ENTRAPMENT HAZARDS IN BUNK BEDS § 1213.4 Test methods. (a) Guardrails (see § 1213.3(a)(6...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-14
... development of BG1Luc ER TA test method performance standards. ICCVAM assigned the activities a high priority... Vitro Test Methods for Detecting Potential Endocrine Disruptors. Research Triangle Park, NC: National...Final.pdf . ICCVAM. 2003a. ICCVAM Evaluation of In Vitro Test Methods For Detecting Potential Endocrine...
ERIC Educational Resources Information Center
Patalino, Marianne
Problems in current course evaluation methods are discussed and an alternative method is described for the construction, analysis, and interpretation of a test to evaluate instructional programs. The method presented represents a different approach to the traditional overreliance on standardized achievement tests and the total scores they provide.…
White, Donald J; Schneiderman, Eva; Colón, Ellen; St John, Samuel
2015-01-01
This paper describes the development and standardization of a profilometry-based method for assessment of dentifrice abrasivity called Radioactive Dentin Abrasivity - Profilometry Equivalent (RDA-PE). Human dentine substrates are mounted in acrylic blocks of precise standardized dimensions, permitting mounting and brushing in V8 brushing machines. Dentin blocks are masked to create an area of "contact brushing." Brushing is carried out in V8 brushing machines and dentifrices are tested as slurries. An abrasive standard is prepared by diluting the ISO 11609 abrasivity reference calcium pyrophosphate abrasive into carboxymethyl cellulose/glycerin, just as in the RDA method. Following brushing, masked areas are removed and profilometric analysis is carried out on treated specimens. Assessments of average abrasion depth (contact or optical profilometry) are made. Inclusion of standard calcium pyrophosphate abrasive permits a direct RDA equivalent assessment of abrasion, which is characterized with profilometry as Depth test/Depth control x 100. Within the test, the maximum abrasivity standard of 250 can be created in situ simply by including a treatment group of standard abrasive with 2.5x number of brushing strokes. RDA-PE is enabled in large part by the availability of easy-to-use and well-standardized modern profilometers, but its use in V8 brushing machines is enabled by the unique specific conditions described herein. RDA-PE permits the evaluation of dentifrice abrasivity to dentin without the requirement of irradiated teeth and infrastructure for handling them. In direct comparisons, the RDA-PE method provides dentifrice abrasivity assessments comparable to the gold industry standard RDA technique.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
In this report, the scope of the tests, the method of analysis, the results, and the conclusions are discussed. The first test indicated that the requirements generated by the Standard procedures and formulae appear to yield reasonable results, although some of the cost data provided as defaults in the Standard should be reevaluated. The second test provided experience that was useful in modifying the points compliance format, but did not uncover any procedural issues that would lead to unreasonable results. These conclusions are based on analysis using the Automated Residential Energy Standard (ARES) computer program, developed to simplify the processmore » of standards generation.« less
A study on setting of the fatigue limit of temporary dental implants.
Kim, M H; Cho, E J; Lee, J W; Kim, E K; Yoo, S H; Park, C W
2017-07-01
A temporary dental implant is a medical device which is temporarily used to support a prosthesis such as an artificial tooth used for restoring patient's masticatory function during implant treatment. It is implanted in the oral cavity to substitute for the role of tooth. Due to the aging and westernization of current Korean society, the number of tooth extraction and implantation procedures is increasing, leading to an increase in the use and development of temporary dental implants. Because an implant performs a masticatory function in place of a tooth, a dynamic load is repeatedly put on the implant. Thus, the fatigue of implants is reported to be the most common causes of the fracture thereof. According to the investigation and analysis of the current domestic and international standards, the standard for fatigue of implant fixtures is not separately specified. Although a test method for measuring the fatigue is suggested in an ISO standard, it is a standard for permanent dental implants. Most of the test standards for Korean manufacturers and importers apply 250 N or more based on the guidance for the safety and performance evaluation of dental implants. Therefore, this study is intended to figure out the fatigue standard which can be applied to temporary dental implants when measuring the fatigue according to the test method suggested in the permanent dental implant standard. The results determined that suitable fatigue standards of temporary dental implants should be provided by each manufacturer rather than applying 250 N. This study will be useful for the establishment of the fatigue standards and fatigue test methods of the manufacturers and importers of temporary dental implants.
Evaluation of a standard test method for screening fuels in soils
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sorini, S.S.; Schabron, J.F.
1996-12-31
A new screening method for fuel contamination in soils was recently developed as American Society for Testing and Materials (ASTM) Method D-5831-95, Standard Test Method for Screening Fuels in Soils. This method uses low-toxicity chemicals and can be sued to screen organic- rich soils, as well as being fast, easy, and inexpensive to perform. Fuels containing aromatic compounds, such as diesel fuel and gasoline, as well as other aromatic-containing hydrocarbon materials, such as motor oil, crude oil, and cola oil, can be determined. The screening method for fuels in soils was evaluated by conducting a Collaborative study on the method.more » In the Collaborative study, a sand and an organic soil spiked with various concentrations of diesel fuel were tested. Data from the Collaborative study were used to determine the reproducibility (between participants) and repeatability (within participants) precision of the method for screening the test materials. The Collaborative study data also provide information on the performance of portable field equipment (patent pending) versus laboratory equipment for performing the screening method and a comparison of diesel concentration values determined using the screening method versus a laboratory method.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Neymark, J.; Kennedy, M.; Judkoff, R.
This report documents a set of diagnostic analytical verification cases for testing the ability of whole building simulation software to model the air distribution side of typical heating, ventilating and air conditioning (HVAC) equipment. These cases complement the unitary equipment cases included in American National Standards Institute (ANSI)/American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs, which test the ability to model the heat-transfer fluid side of HVAC equipment.
Methodological Issues in Antifungal Susceptibility Testing of Malassezia pachydermatis
Peano, Andrea; Pasquetti, Mario; Tizzani, Paolo; Chiavassa, Elisa; Guillot, Jacques; Johnson, Elizabeth
2017-01-01
Reference methods for antifungal susceptibility testing of yeasts have been developed by the Clinical and Laboratory Standards Institute (CLSI) and the European Committee on Antibiotic Susceptibility Testing (EUCAST). These methods are intended to test the main pathogenic yeasts that cause invasive infections, namely Candida spp. and Cryptococcus neoformans, while testing other yeast species introduces several additional problems in standardization not addressed by these reference procedures. As a consequence, a number of procedures have been employed in the literature to test the antifungal susceptibility of Malassezia pachydermatis. This has resulted in conflicting results. The aim of the present study is to review the procedures and the technical parameters (growth media, inoculum preparation, temperature and length of incubation, method of reading) employed for susceptibility testing of M. pachydermatis, and when possible, to propose recommendations for or against their use. Such information may be useful for the future development of a reference assay. PMID:29371554
Alignment as a Teacher Variable
ERIC Educational Resources Information Center
Porter, Andrew C.; Smithson, John; Blank, Rolf; Zeidner, Timothy
2007-01-01
With the exception of the procedures developed by Porter and colleagues (Porter, 2002), other methods of defining and measuring alignment are essentially limited to alignment between tests and standards. Porter's procedures have been generalized to investigating the alignment between content standards, tests, textbooks, and even classroom…
Verster, Joris C; Roth, Thomas
2011-01-01
This review discusses the methodology of the standardized on-the-road driving test and standard operation procedures to conduct the test and analyze the data. The on-the-road driving test has proven to be a sensitive and reliable method to examine driving ability after administration of central nervous system (CNS) drugs. The test is performed on a public highway in normal traffic. Subjects are instructed to drive with a steady lateral position and constant speed. Its primary parameter, the standard deviation of lateral position (SDLP), ie, an index of 'weaving', is a stable measure of driving performance with high test-retest reliability. SDLP differences from placebo are dose-dependent, and do not depend on the subject's baseline driving skills (placebo SDLP). It is important that standard operation procedures are applied to conduct the test and analyze the data in order to allow comparisons between studies from different sites.
46 CFR 164.120-5 - Incorporation by reference.
Code of Federal Regulations, 2014 CFR
2014-10-01
...), Standard Test Method for Apparent Viscosity of Plastisols and Organosols at Low Shear Rates, (approved...—Determination of apparent viscosity by the Brookfield test method, Second Edition (February 1, 1989, Corrected...
46 CFR 164.120-5 - Incorporation by reference.
Code of Federal Regulations, 2013 CFR
2013-10-01
...), Standard Test Method for Apparent Viscosity of Plastisols and Organosols at Low Shear Rates, (approved...—Determination of apparent viscosity by the Brookfield test method, Second Edition (February 1, 1989, Corrected...
15 CFR 16.2 - Description and goal of program.
Code of Federal Regulations, 2014 CFR
2014-01-01
... standardized test methods by which selected product performance characteristics can be measured; (2) Developing... voluntarily to test and label their products according to the selected or developed methods; and (4...
15 CFR 16.2 - Description and goal of program.
Code of Federal Regulations, 2013 CFR
2013-01-01
... standardized test methods by which selected product performance characteristics can be measured; (2) Developing... voluntarily to test and label their products according to the selected or developed methods; and (4...
15 CFR 16.2 - Description and goal of program.
Code of Federal Regulations, 2012 CFR
2012-01-01
... standardized test methods by which selected product performance characteristics can be measured; (2) Developing... voluntarily to test and label their products according to the selected or developed methods; and (4...
Phinney, Karen W; Sempos, Christopher T; Tai, Susan S-C; Camara, Johanna E; Wise, Stephen A; Eckfeldt, John H; Hoofnagle, Andrew N; Carter, Graham D; Jones, Julia; Myers, Gary L; Durazo-Arvizu, Ramon; Miller, W Greg; Bachmann, Lorin M; Young, Ian S; Pettit, Juanita; Caldwell, Grahame; Liu, Andrew; Brooks, Stephen P J; Sarafin, Kurtis; Thamm, Michael; Mensink, Gert B M; Busch, Markus; Rabenberg, Martina; Cashman, Kevin D; Kiely, Mairead; Galvin, Karen; Zhang, Joy Y; Kinsella, Michael; Oh, Kyungwon; Lee, Sun-Wha; Jung, Chae L; Cox, Lorna; Goldberg, Gail; Guberg, Kate; Meadows, Sarah; Prentice, Ann; Tian, Lu; Brannon, Patsy M; Lucas, Robyn M; Crump, Peter M; Cavalier, Etienne; Merkel, Joyce; Betz, Joseph M
2017-09-01
The Vitamin D Standardization Program (VDSP) coordinated a study in 2012 to assess the commutability of reference materials and proficiency testing/external quality assurance materials for total 25-hydroxyvitamin D [25(OH)D] in human serum, the primary indicator of vitamin D status. A set of 50 single-donor serum samples as well as 17 reference and proficiency testing/external quality assessment materials were analyzed by participating laboratories that used either immunoassay or LC-MS methods for total 25(OH)D. The commutability test materials included National Institute of Standards and Technology Standard Reference Material 972a Vitamin D Metabolites in Human Serum as well as materials from the College of American Pathologists and the Vitamin D External Quality Assessment Scheme. Study protocols and data analysis procedures were in accordance with Clinical and Laboratory Standards Institute guidelines. The majority of the test materials were found to be commutable with the methods used in this commutability study. These results provide guidance for laboratories needing to choose appropriate reference materials and select proficiency or external quality assessment programs and will serve as a foundation for additional VDSP studies.
Shehata, Atef S.; Mukherjee, Pranab K.; Ghannoum, Mahmoud A.
2008-01-01
In this study, we determined the utility of a 2,3-bis(2-methoxy-4-nitro-5-[(sulfenylamino)carbonyl]-2H-tetrazolium hydroxide (XTT)-based assay for determining antifungal susceptibilities of dermatophytes to terbinafine, ciclopirox, and voriconazole in comparison to the Clinical and Laboratory Standards Institute (CLSI) M38-A2 method. Forty-eight dermatophyte isolates, including Trichophyton rubrum (n = 15), Trichophyton mentagrophytes (n = 7), Trichophyton tonsurans (n = 11), and Epidermophyton floccosum (n = 13), and two quality control strains, were tested. In the XTT-based method, MICs were determined spectrophotometrically at 490 nm after addition of XTT and menadione. For the CLSI method, the MICs were determined visually. With T. rubrum, the XTT assay revealed MIC ranges of 0.004 to >64 μg/ml, 0.125 to 0.25 μg/ml, and 0.008 to 0.025 μg/ml for terbinafine, ciclopirox, and voriconazole, respectively. Similar MIC ranges were obtained against T. rubrum by using the CLSI method. Additionally, when tested with T. mentagrophytes, T. tonsurans, and E. floccosum isolates, the XTT and CLSI methods resulted in comparable MIC ranges. Both methods revealed similar lowest drug concentrations that inhibited 90% of the isolates for the majority of tested drug-dermatophyte combinations. The levels of agreement within 1 dilution between both methods were as follows: 100% with terbinafine, 97.8% with ciclopirox, and 89.1% with voriconazole. However, the agreement within 2 dilutions between these two methods was 100% for all tested drugs. Our results revealed that the XTT assay can be a useful tool for antifungal susceptibility testing of dermatophytes. PMID:18832129
Proposed test method for and evaluation of wheelchair seating system (WCSS) crashworthiness.
van Roosmalen, L; Bertocci, G; Ha, D R; Karg, P; Szobota, S
2000-01-01
Safety of motor vehicle seats is of great importance in providing crash protection to the occupant. An increasing number of wheelchair users use their wheelchairs as motor vehicle seats when traveling. A voluntary standard requires that compliant wheelchairs be dynamically sled impact tested. However, testing to evaluate the crashworthiness of add-on wheelchair seating systems (WCSS) independent of their wheelchair frame is not addressed by this standard. To address this need, this study developed a method to evaluate the crash-worthiness of WCSS with independent frames. Federal Motor Vehicle Safety Standards (FMVSS) 207 test protocols, used to test the strength of motor vehicle seats, were modified and used to test the strength of three WCSS. Forward and rearward loads were applied at the WCSS center of gravity (CGSS), and a moment was applied at the uppermost point of the seat back. Each of the three tested WCSS met the strength requirements of FMVSS 207. Wheelchair seat-back stiffness was also investigated and compared to motor vehicle seat-back stiffness.
Standard methods for open hole tension testing of textile composites
NASA Technical Reports Server (NTRS)
Portanova, M. A.; Masters, J. E.
1995-01-01
Sizing effects have been investigated by comparing the open hole failure strengths of each of the four different braided architectures as a function of specimen thickness, hole diameter, and the ratio of specimen width to hole diameter. The data used to make these comparisons was primarily generated by Boeing. Direct comparisons of Boeing's results were made with experiments conducted at West Virginia University whenever possible. Indirect comparisons were made with test results for other 2-D braids and 3-D weaves tested by Boeing and Lockheed. In general, failure strength was found to decrease with increasing plate thickness, increase with decreasing hole size, and decreasing with decreasing width to diameter ratio. The interpretation of the sensitive to each of these geometrical parameters was complicated by scatter in the test data. For open hole tension testing of textile composites, the use of standard testing practices employed by industry, such as ASTM D5766 - Standard Test Method for Open Hole Tensile Strength of Polymer Matrix Composite Laminates should provide adequate results for material comparisons studies.
Liu, Yan; Yang, Dong; Xiong, Fen; Yu, Lan; Ji, Fei; Wang, Qiu-Ju
2015-09-01
Hearing loss affects more than 27 million people in mainland China. It would be helpful to develop a portable and self-testing audiometer for the timely detection of hearing loss so that the optimal clinical therapeutic schedule can be determined. The objective of this study was to develop a software-based hearing self-testing system. The software-based self-testing system consisted of a notebook computer, an external sound card, and a pair of 10-Ω insert earphones. The system could be used to test the hearing thresholds by individuals themselves in an interactive manner using software. The reliability and validity of the system at octave frequencies of 0.25 Hz to 8.0 kHz were analyzed in three series of experiments. Thirty-seven normal-hearing particpants (74 ears) were enrolled in experiment 1. Forty individuals (80 ears) with sensorineural hearing loss (SNHL) participated in experiment 2. Thirteen normal-hearing participants (26 ears) and 37 participants (74 ears) with SNHL were enrolled in experiment 3. Each participant was enrolled in only one of the three experiments. In all experiments, pure-tone audiometry in a sound insulation room (standard test) was regarded as the gold standard. SPSS for Windows, version 17.0, was used for statistical analysis. The paired t-test was used to compare the hearing thresholds between the standard test and software-based self-testing (self-test) in experiments 1 and 2. In experiment 3 (main study), one-way analysis of variance and post hoc comparisons were used to compare the hearing thresholds among the standard test and two rounds of the self-test. Linear correlation analysis was carried out for the self-tests performed twice. The concordance was analyzed between the standard test and the self-test using the kappa method. p < 0.05 was considered statistically significant. Experiments 1 and 2: The hearing thresholds determined by the two methods were not significantly different at frequencies of 250, 500, or 8000 Hz (p > 0.05) but were significantly different at frequencies of 1000, 2000, and 4000 Hz (p < 0.05), except for 1000 Hz in the right ear in experiment 2. Experiment 3: The hearing thresholds determined by the standard test and self-tests repeated twice were not significantly different at any frequency (p > 0.05). The overall sensitivity of the self-test method was 97.6%, and the specificity was 98.3%. The sensitivity was 97.6% and the specificity was 97% for the patients with SNHL. The self-test had significant concordance with the standard test (kappa value = 0.848, p < 0.001). This portable hearing self-testing system based on a notebook personal computer is a reliable and sensitive method for hearing threshold assessment and monitoring. American Academy of Audiology.
[Optimization of cluster analysis based on drug resistance profiles of MRSA isolates].
Tani, Hiroya; Kishi, Takahiko; Gotoh, Minehiro; Yamagishi, Yuka; Mikamo, Hiroshige
2015-12-01
We examined 402 methicillin-resistant Staphylococcus aureus (MRSA) strains isolated from clinical specimens in our hospital between November 19, 2010 and December 27, 2011 to evaluate the similarity between cluster analysis of drug susceptibility tests and pulsed-field gel electrophoresis (PFGE). The results showed that the 402 strains tested were classified into 27 PFGE patterns (151 subtypes of patterns). Cluster analyses of drug susceptibility tests with the cut-off distance yielding a similar classification capability showed favorable results--when the MIC method was used, and minimum inhibitory concentration (MIC) values were used directly in the method, the level of agreement with PFGE was 74.2% when 15 drugs were tested. The Unweighted Pair Group Method with Arithmetic mean (UPGMA) method was effective when the cut-off distance was 16. Using the SIR method in which susceptible (S), intermediate (I), and resistant (R) were coded as 0, 2, and 3, respectively, according to the Clinical and Laboratory Standards Institute (CLSI) criteria, the level of agreement with PFGE was 75.9% when the number of drugs tested was 17, the method used for clustering was the UPGMA, and the cut-off distance was 3.6. In addition, to assess the reproducibility of the results, 10 strains were randomly sampled from the overall test and subjected to cluster analysis. This was repeated 100 times under the same conditions. The results indicated good reproducibility of the results, with the level of agreement with PFGE showing a mean of 82.0%, standard deviation of 12.1%, and mode of 90.0% for the MIC method and a mean of 80.0%, standard deviation of 13.4%, and mode of 90.0% for the SIR method. In summary, cluster analysis for drug susceptibility tests is useful for the epidemiological analysis of MRSA.
NASA Technical Reports Server (NTRS)
Larkin, Paul; Goldstein, Bob
2008-01-01
This paper presents an update to the methods and procedures used in Direct Field Acoustic Testing (DFAT). The paper will discuss some of the recent techniques and developments that are currently being used and the future publication of a reference standard. Acoustic testing using commercial sound system components is becoming a popular and cost effective way of generating a required acoustic test environment both in and out of a reverberant chamber. This paper will present the DFAT test method, the usual setup and procedure and the development and use of a closed-loop, narrow-band control system. Narrow-band control of the acoustic PSD allows all standard techniques and procedures currently used in random control to be applied to acoustics and some examples are given. The paper will conclude with a summary of the development of a standard practice guideline that is hoped to be available in the first quarter of next year.
A SIMPLE METHOD FOR EVALUATING DATA FROM AN INTERLABORATORY STUDY
Large-scale laboratory-and method-performance studies involving more than about 30 laboratories may be evaluated by calculating the HORRAT ratio for each test sample (HORRAT=[experimentally found among-laboratories relative standard deviation] divided by [relative standard deviat...
Full-Field Strain Methods for Investigating Failure Mechanisms in Triaxial Braided Composites
NASA Technical Reports Server (NTRS)
Littell, Justin D.; Binienda, Wieslaw K.; Goldberg, Robert K.; Roberts, Gary D.
2008-01-01
Recent advancements in braiding technology have led to commercially viable manufacturing approaches for making large structures with complex shape out of triaxial braided composite materials. In some cases, the static load capability of structures made using these materials has been higher than expected based on material strength properties measured using standard coupon tests. A more detailed investigation of deformation and failure processes in large-unit-cell-size triaxial braid composites is needed to evaluate the applicability of standard test methods for these materials and to develop alternative testing approaches. This report presents some new techniques that have been developed to investigate local deformation and failure using digital image correlation techniques. The methods were used to measure both local and global strains during standard straight-sided coupon tensile tests on composite materials made with 12- and 24-k yarns and a 0 /+60 /-60 triaxial braid architecture. Local deformation and failure within fiber bundles was observed and correlations were made between these local failures and global composite deformation and strength.
Hydrogen Field Test Standard: Laboratory and Field Performance
Pope, Jodie G.; Wright, John D.
2015-01-01
The National Institute of Standards and Technology (NIST) developed a prototype field test standard (FTS) that incorporates three test methods that could be used by state weights and measures inspectors to periodically verify the accuracy of retail hydrogen dispensers, much as gasoline dispensers are tested today. The three field test methods are: 1) gravimetric, 2) Pressure, Volume, Temperature (PVT), and 3) master meter. The FTS was tested in NIST's Transient Flow Facility with helium gas and in the field at a hydrogen dispenser location. All three methods agree within 0.57 % and 1.53 % for all test drafts of helium gas in the laboratory setting and of hydrogen gas in the field, respectively. The time required to perform six test drafts is similar for all three methods, ranging from 6 h for the gravimetric and master meter methods to 8 h for the PVT method. The laboratory tests show that 1) it is critical to wait for thermal equilibrium to achieve density measurements in the FTS that meet the desired uncertainty requirements for the PVT and master meter methods; in general, we found a wait time of 20 minutes introduces errors < 0.1 % and < 0.04 % in the PVT and master meter methods, respectively and 2) buoyancy corrections are important for the lowest uncertainty gravimetric measurements. The field tests show that sensor drift can become a largest component of uncertainty that is not present in the laboratory setting. The scale was calibrated after it was set up at the field location. Checks of the calibration throughout testing showed drift of 0.031 %. Calibration of the master meter and the pressure sensors prior to travel to the field location and upon return showed significant drifts in their calibrations; 0.14 % and up to 1.7 %, respectively. This highlights the need for better sensor selection and/or more robust sensor testing prior to putting into field service. All three test methods are capable of being successfully performed in the field and give equivalent answers if proper sensors without drift are used. PMID:26722192
Criteria for establishing water quality standards that are protective of all native biota are generally based upon laboratory toxicity tests. These test utilize common model organisms that have established test methods. However, only a small portion of species have established ...
USDA-ARS?s Scientific Manuscript database
The supplemental information presented in this document is intended for use with the antimicrobial susceptibility testing procedures published in the following Clinical and Laboratory Standards Institute (CLSI) approved documents VET03-A Methods for Antimicrobial Disk Susceptibility Testing of Bacte...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kane, V.E.
1982-01-01
A class of goodness-of-fit estimators is found to provide a useful alternative in certain situations to the standard maximum likelihood method which has some undesirable estimation characteristics for estimation from the three-parameter lognormal distribution. The class of goodness-of-fit tests considered include the Shapiro-Wilk and Filliben tests which reduce to a weighted linear combination of the order statistics that can be maximized in estimation problems. The weighted order statistic estimators are compared to the standard procedures in Monte Carlo simulations. Robustness of the procedures are examined and example data sets analyzed.
21 CFR 178.3740 - Plasticizers in polymeric substances.
Code of Federal Regulations, 2014 CFR
2014-04-01
..., hydrogenated (minimum viscosity at 99 °F, 39 Saybolt Universal seconds, as determined by ASTM methods D445-82 (“Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and the Calculation of Dynamic Viscosity)”) and D2161-82 (“Standard Method for Conversion of Kinematic Viscosity to Saybolt...
ERIC Educational Resources Information Center
Choi, Sae Il
2009-01-01
This study used simulation (a) to compare the kernel equating method to traditional equipercentile equating methods under the equivalent-groups (EG) design and the nonequivalent-groups with anchor test (NEAT) design and (b) to apply the parametric bootstrap method for estimating standard errors of equating. A two-parameter logistic item response…
15 CFR 10.11 - Revision or amendment of a standard.
Code of Federal Regulations, 2012 CFR
2012-01-01
... or the design characteristics of the product being standardized, or which cannot reasonably be... only one subsection of the requirement section and/or only one subsection of the test methods section... being standardized, the standard need not be reidentified. (c) An amendment to a standard shall be...
15 CFR 10.11 - Revision or amendment of a standard.
Code of Federal Regulations, 2013 CFR
2013-01-01
... or the design characteristics of the product being standardized, or which cannot reasonably be... only one subsection of the requirement section and/or only one subsection of the test methods section... being standardized, the standard need not be reidentified. (c) An amendment to a standard shall be...
15 CFR 10.11 - Revision or amendment of a standard.
Code of Federal Regulations, 2010 CFR
2010-01-01
... or the design characteristics of the product being standardized, or which cannot reasonably be... only one subsection of the requirement section and/or only one subsection of the test methods section... being standardized, the standard need not be reidentified. (c) An amendment to a standard shall be...
15 CFR 10.11 - Revision or amendment of a standard.
Code of Federal Regulations, 2011 CFR
2011-01-01
... or the design characteristics of the product being standardized, or which cannot reasonably be... only one subsection of the requirement section and/or only one subsection of the test methods section... being standardized, the standard need not be reidentified. (c) An amendment to a standard shall be...
15 CFR 10.11 - Revision or amendment of a standard.
Code of Federal Regulations, 2014 CFR
2014-01-01
... or the design characteristics of the product being standardized, or which cannot reasonably be... only one subsection of the requirement section and/or only one subsection of the test methods section... being standardized, the standard need not be reidentified. (c) An amendment to a standard shall be...
Dry and wet arc track propagation resistance testing
NASA Technical Reports Server (NTRS)
Beach, Rex
1995-01-01
The wet arc-propagation resistance test for wire insulation provides an assessment of the ability of an insulation to prevent damage in an electrical environment. Results of an arc-propagation test may vary slightly due to the method of arc initiation; therefore a standard test method must be selected to evaluate the general arc-propagation resistance characteristics of an insulation. This test method initiates an arc by dripping salt water over pre-damaged wires which creates a conductive path between the wires. The power supply, test current, circuit resistances, and other variables are optimized for testing 20 guage wires. The use of other wire sizes may require modifications to the test variables. The dry arc-propagation resistance test for wire insulation also provides an assessment of the ability of an insulation to prevent damage in an electrical arc environment. In service, electrical arcs may originate form a variety of factors including insulation deterioration, faulty installation, and chafing. Here too, a standard test method must be selected to evaluate the general arc-propagation resistance characteristics of an insulation. This test method initiates an arc with a vibrating blade. The test also evaluates the ability of the insulation to prevent further arc-propagation when the electrical arc is re-energized.
40 CFR 60.66 - Delegation of authority.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Portland Cement Plants § 60... alternative to any non-opacity emissions standard. (2) Approval of a major change to test methods under § 60.8...
LABORATORY TOXICITY TESTS FOR EVALUATING POTENTIAL EFFECTS OF ENDOCRINE-DISRUPTING COMPOUNDS
The scope of the Laboratory Testing Work Group was to evaluate methods for testing aquatic and terrestrial invertebrates in the laboratory. Specifically, discussions focused on the following objectives: 1) assess the extent to which consensus-based standard methods and other pub...
16 CFR 1633.3 - General requirements.
Code of Federal Regulations, 2010 CFR
2010-01-01
... FLAMMABILITY (OPEN FLAME) OF MATTRESS SETS The Standard § 1633.3 General requirements. (a) Summary of test method. The test method set forth in § 1633.7 measures the flammability (fire test response... allowing it to burn freely under well-ventilated, controlled environmental conditions. The flaming ignition...
NASA Astrophysics Data System (ADS)
Sadowski, T.; Kneć, M.
2016-04-01
Fatigue tests were conducted since more than two hundred years ago. Despite this long period, as fatigue phenomena are very complex, assessment of fatigue response of standard materials or composites still requires a long time. Quite precise way to estimate fatigue parameters is to test at least 30 standardized specimens for the analysed material and further statistical post processing is required. In case of structural elements analysis like hybrid joints (Figure 1), the situation is much more complex as more factors influence the fatigue load capacity due to much more complicated structure of the joint in comparison to standard materials specimen, i.e. occurrence of: welded hot spots or rivets, adhesive layers, local notches creating the stress concentrations, etc. In order to shorten testing time some rapid methods are known: Locati's method [1] - step by step load increments up to failure, Prot's method [2] - constant increase of the load amplitude up to failure; Lehr's method [2] - seeking for the point during regular fatigue loading when an increase of temperature or strains become non-linear. The present article proposes new method of the fatigue response assessment - combination of the Locati's and Lehr's method.
Silbernagel, Karen M; Jechorek, Robert P; Kaufer, Amanda L; Johnson, Ronald L; Aleo, V; Brown, B; Buen, M; Buresh, J; Carson, M; Franklin, J; Ham, P; Humes, L; Husby, G; Hutchins, J; Jechorek, R; Jenkins, J; Kaufer, A; Kexel, N; Kora, L; Lam, L; Lau, D; Leighton, S; Loftis, M; Luc, S; Martin, J; Nacar, I; Nogle, J; Park, J; Schultz, A; Seymore, D; Smith, C; Smith, J; Thou, P; Ulmer, M; Voss, R; Weaver, V
2005-01-01
A multilaboratory study was conducted to compare the VIDAS LIS immunoassay with the standard cultural methods for the detection of Listeria in foods using an enrichment modification of AOAC Official Method 999.06. The modified enrichment protocol was implemented to harmonize the VIDAS LIS assay with the VIDAS LMO2 assay. Five food types--brie cheese, vanilla ice cream, frozen green beans, frozen raw tilapia fish, and cooked roast beef--at 3 inoculation levels, were analyzed by each method. A total of 15 laboratories representing government and industry participated. In this study, 1206 test portions were tested, of which 1170 were used in the statistical analysis. There were 433 positive by the VIDAS LIS assay and 396 positive by the standard culture methods. A Chi-square analysis of each of the 5 food types, at the 3 inoculation levels tested, was performed. The resulting average Chi square analysis, 0.42, indicated that, overall, there are no statistical differences between the VIDAS LIS assay and the standard methods at the 5% level of significance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arnold, G.; Nelson, S.; Cooperrider, N.K.
1982-02-11
This report, Volume II, contains the results, conclusions, and recommendations of the first performance test of a transit care on the RDU. This report is limited to performance tests. The objective is to identify advantages and disadvantages of performance testing on the rollers of the RDU as highlighted by the SOAC test. The report involved separate testing, done by TTC personnel, in such traditional performance areas of transit vehicle operation ass traction, acceleration/deceleration, energy consumption, and spin/slide performance. The results of the successful performance test of a transit car on a roller unit is presented and the advantages of thismore » method of testing is discussed. Acceleration, deceleration, spin/slide, and power consumption tests, although of limited scope in comparison to the track tests performed on the same transit car, did show the feasibility of roller testing. It is concluded that the RDU is most suited for developmental testing of transit car systems particularly for power consumption and for cars with non-standard wheel gage. Tests should be of such scope as to justify the cost of car setup on the RDU. The following two test are recommended: (1) a power consumption study for a standard/non-standard gage transit car which investigates methods of reducing power consumption and (2) a non-standard gage full performance test.« less
Huang, Ay Huey; Wu, Jiunn Jong; Weng, Yu Mei; Ding, Hwia Cheng; Chang, Tsung Chain
1998-01-01
Nonfastidious aerobic gram-negative bacilli (GNB) are commonly isolated from blood cultures. The feasibility of using an electrochemical method for direct antimicrobial susceptibility testing of GNB in positive blood cultures was evaluated. An aliquot (10 μl) of 1:10-diluted positive blood cultures containing GNB was inoculated into the Bactometer module well (bioMérieux Vitek, Hazelwood, Mo.) containing 1 ml of Mueller-Hinton broth supplemented with an antibiotic. Susceptibility tests were performed in a breakpoint broth dilution format, with the results being categorized as resistant, intermediate, or susceptible. Seven antibiotics (ampicillin, cephalothin, gentamicin, amikacin, cefamandole, cefotaxime, and ciprofloxacin) were used in this study, with each agent being tested at the two interpretive breakpoint concentrations. The inoculated modules were incubated at 35°C, and the change in impedance in each well was continuously monitored for 24 h by the Bactometer. The MICs of the seven antibiotics for each blood isolate were also determined by the standardized broth microdilution method. Of 146 positive blood cultures (1,022 microorganism-antibiotic combinations) containing GNB tested by the direct method, the rates of very major, major, and minor errors were 0, 1.1, and 2.5%, respectively. The impedance method was simple; no centrifugation, preincubation, or standardization of the inocula was required, and the susceptibility results were normally available within 3 to 6 h after inoculation. The rapid method may allow proper antimicrobial treatment almost 30 to 40 h before the results of the standard methods are available. PMID:9738038
Confidence Limits for the Indirect Effect: Distribution of the Product and Resampling Methods
ERIC Educational Resources Information Center
MacKinnon, David P.; Lockwood, Chondra M.; Williams, Jason
2004-01-01
The most commonly used method to test an indirect effect is to divide the estimate of the indirect effect by its standard error and compare the resulting z statistic with a critical value from the standard normal distribution. Confidence limits for the indirect effect are also typically based on critical values from the standard normal…
A New Test Unit for Disintegration End-Point Determination of Orodispersible Films.
Low, Ariana; Kok, Si Ling; Khong, Yuet Mei; Chan, Sui Yung; Gokhale, Rajeev
2015-11-01
No standard time or pharmacopoeia disintegration test method for orodispersible films (ODFs) exists. The USP disintegration test for tablets and capsules poses significant challenges for end-point determination when used for ODFs. We tested a newly developed disintegration test unit (DTU) against the USP disintegration test. The DTU is an accessory to the USP disintegration apparatus. It holds the ODF in a horizontal position, allowing top-view of the ODF during testing. A Gauge R&R study was conducted to assign relative contributions of the total variability from the operator, sample or the experimental set-up. Precision was compared using commercial ODF products in different media. Agreement between the two measurement methods was analysed. The DTU showed improved repeatability and reproducibility compared to the USP disintegration system with tighter standard deviations regardless of operator or medium. There is good agreement between the two methods, with the USP disintegration test giving generally longer disintegration times possibly due to difficulty in end-point determination. The DTU provided clear end-point determination and is suitable for quality control of ODFs during product developmental stage or manufacturing. This may facilitate the development of a standardized methodology for disintegration time determination of ODFs. © 2015 Wiley Periodicals, Inc. and the American Pharmacists Association.
40 CFR 63.2993 - What test methods must I use in conducting performance tests?
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 13 2012-07-01 2012-07-01 false What test methods must I use in conducting performance tests? 63.2993 Section 63.2993 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED) National...
40 CFR 63.2993 - What test methods must I use in conducting performance tests?
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 13 2014-07-01 2014-07-01 false What test methods must I use in conducting performance tests? 63.2993 Section 63.2993 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED) National...
NASA Astrophysics Data System (ADS)
Stare, E.; Beges, G.; Drnovsek, J.
2006-07-01
This paper presents the results of research into the measurement of the resistance of solid isolating materials to tracking. Two types of tracking were investigated: the proof tracking index (PTI) and the comparative tracking index (CTI). Evaluation of the measurement uncertainty in a case study was performed using a test method in accordance with the IEC 60112 standard. In the scope of the tests performed here, this particular test method was used to ensure the safety of electrical appliances. According to the EN ISO/IEC 17025 standard (EN ISO/IEC 17025), in the process of conformity assessment, the evaluation of the measurement uncertainty of the test method should be carried out. In the present article, possible influential parameters that are in accordance with the third and fourth editions of the standard IEC 60112 are discussed. The differences, ambiguities or lack of guidance referring to both editions of the standard are described in the article 'Ambiguities in technical standards—case study IEC 60112—measuring the resistance of solid isolating materials to tracking' (submitted for publication). Several hundred measurements were taken in the present experiments in order to form the basis for the results and conclusions presented. A specific problem of the test (according to the IEC 60112 standard) is the great variety of influential physical parameters (mechanical, electrical, chemical, etc) that can affect the results. At the end of the present article therefore, there is a histogram containing information on the contributions to the measurement uncertainty.
Measurement of Energy Performances for General-Structured Servers
NASA Astrophysics Data System (ADS)
Liu, Ren; Chen, Lili; Li, Pengcheng; Liu, Meng; Chen, Haihong
2017-11-01
Energy consumption of servers in data centers increases rapidly along with the wide application of Internet and connected devices. To improve the energy efficiency of servers, voluntary or mandatory energy efficiency programs for servers, including voluntary label program or mandatory energy performance standards have been adopted or being prepared in the US, EU and China. However, the energy performance of servers and testing methods of servers are not well defined. This paper presents matrices to measure the energy performances of general-structured servers. The impacts of various components of servers on their energy performances are also analyzed. Based on a set of normalized workload, the author proposes a standard method for testing energy efficiency of servers. Pilot tests are conducted to assess the energy performance testing methods of servers. The findings of the tests are discussed in the paper.
ERIC Educational Resources Information Center
Fowell, S. L.; Fewtrell, R.; McLaughlin, P. J.
2008-01-01
Absolute standard setting procedures are recommended for assessment in medical education. Absolute, test-centred standard setting procedures were introduced for written assessments in the Liverpool MBChB in 2001. The modified Angoff and Ebel methods have been used for short answer question-based and extended matching question-based papers,…
Verster, Joris C; Roth, Thomas
2011-01-01
This review discusses the methodology of the standardized on-the-road driving test and standard operation procedures to conduct the test and analyze the data. The on-the-road driving test has proven to be a sensitive and reliable method to examine driving ability after administration of central nervous system (CNS) drugs. The test is performed on a public highway in normal traffic. Subjects are instructed to drive with a steady lateral position and constant speed. Its primary parameter, the standard deviation of lateral position (SDLP), ie, an index of ‘weaving’, is a stable measure of driving performance with high test–retest reliability. SDLP differences from placebo are dose-dependent, and do not depend on the subject’s baseline driving skills (placebo SDLP). It is important that standard operation procedures are applied to conduct the test and analyze the data in order to allow comparisons between studies from different sites. PMID:21625472
Spray Drift Reduction Evaluations of Spray Nozzles Using a Standardized Testing Protocol
2010-07-01
Drop Size Characteristics in a Spray Using Optical Nonimaging Light-Scattering Instruments,” Annual Book of ASTM Standards, Vol. 14-02, ASTM...Test Method for Determining Liquid Drop Size Characteristics in a Spray Using Optical Non- imaging Light-Scattering Instruments 22. AGDISP Model
40 CFR 60.52Da - Recordkeeping requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Electric Utility... opacity field data sheets; (2) For each performance test conducted using Method 22 of appendix A-4 of this... performance test; (iii) Copies of all visible emission observer opacity field data sheets; and (iv...
Present and future molecular testing of lung carcinoma.
Dacic, Sanja; Nikiforova, Marina N
2014-03-01
The rapid development of targeted therapies has tremendously changed clinical management of lung carcinoma patients and set the stage for similar developments in other tumor types. Many studies have been published in the past decade in search for the most acceptable method of assessment for predictors of response to targeted therapies in lung cancer. As a result, several guidelines for molecular testing have been published in a past couple of years. Because of accumulated evidence that targetable drugs show the best efficacy and improved progression survival rates in lung cancer patients whose tumors have a specific genotype, molecular testing for predictors of therapy response has became standard of care. Presently, testing for EGFR mutations and ALK rearrangements in lung adenocarcinoma has been standardized. The landscape of targetable genomic alterations in lung carcinoma is expanding, but none of other potentially targetable biomarkers have been standardized outside of clinical trials. This review will summarize current practice of molecular testing. Future methods in molecular testing of lung carcinoma will be briefly reviewed.
Some possible reference materials for fire toxicity tests
NASA Technical Reports Server (NTRS)
Hilado, C. J.; Solis, A. N.
1977-01-01
Suitable reference materials need to be selected in order to standardize any test method. The evaluation of cotton, polyethylene, polyether sulfone, polycarbonate, polystyrene, and polyurethane flexible and rigid foams as possible reference materials for the University of San Francisco/NASA toxicity screening test method is discussed.
[Overview and prospect of syndrome differentiation of hypertension in traditional Chinese medicine].
Yang, Xiao-Chen; Xiong, Xing-Jiang; Wang, Jie
2014-01-01
This article is to overview the literature of syndrome differentiation of traditional Chinese medicine on hypertension. According to the theory of disease in combination with syndrome, we concluded syndrome types of hypertension in four aspects, including national standards, industry standards, teaching standards and personal experience. Meanwhile, in order to provide new methods and approaches for normalized research, we integrated modern testing methods and statistical methods to analyze syndrome differentiation for the treatment of hypertension.
Novel methods of imaging and analysis for the thermoregulatory sweat test.
Carroll, Michael Sean; Reed, David W; Kuntz, Nancy L; Weese-Mayer, Debra Ellyn
2018-06-07
The thermoregulatory sweat test (TST) can be central to the identification and management of disorders affecting sudomotor function and small sensory and autonomic nerve fibers, but the cumbersome nature of the standard testing protocol has prevented its widespread adoption. A high resolution, quantitative, clean and simple assay of sweating could significantly improve identification and management of these disorders. Images from 89 clinical TSTs were analyzed retrospectively using two novel techniques. First, using the standard indicator powder, skin surface sweat distributions were determined algorithmically for each patient. Second, a fundamentally novel method using thermal imaging of forced evaporative cooling was evaluated through comparison with the standard technique. Correlation and receiver operating characteristic analyses were used to determine the degree of match between these methods, and the potential limits of thermal imaging were examined through cumulative analysis of all studied patients. Algorithmic encoding of sweating and non-sweating regions produces a more objective analysis for clinical decision making. Additionally, results from the forced cooling method correspond well with those from indicator powder imaging, with a correlation across spatial regions of -0.78 (CI: -0.84 to -0.71). The method works similarly across body regions, and frame-by-frame analysis suggests the ability to identify sweating regions within about 1 second of imaging. While algorithmic encoding can enhance the standard sweat testing protocol, thermal imaging with forced evaporative cooling can dramatically improve the TST by making it less time-consuming and more patient-friendly than the current approach.
ERIC Educational Resources Information Center
Venetsanou, Fotini; Kambas, Antonis; Ellinoudis, Theodoros; Fatouros, Ioannis; Giannakidou, Dimitra; Kourtessis, Thomas
2011-01-01
Developmental Coordination Disorder (DCD) is an important risk factor in the development of children that can have a significant academic and social impact. This reinforces the need for its timely identification using appropriate assessment methods and accurate screening tests. The commonly used standardized motor test for the DCD identification…
Zhang, Nan; Zhou, Juan; Yu, Jinlai; Hua, Ziyu; Li, Yongxue; Wu, Jiangang
2018-05-30
Medical injection pump is a commonly used clinical equipment with high risk. Accurate detection of flow is an important aspect to ensure its reliable operation. In this paper, we carefully studied and analyzed the flow detection methods of three standards being used in medical injection pump detection in our country. The three standards were compared from the aspects of standard device, flow test point selection, length of test time and accuracy judgment. The advantages and disadvantages of these standards were analyzed and suggestions for improvement were put forward.
Drawbar Pull (DP) Procedures for Off-Road Vehicle Testing
NASA Technical Reports Server (NTRS)
Creager, Colin; Asnani, Vivake; Oravec, Heather; Woodward, Adam
2017-01-01
As NASA strives to explore the surface of the Moon and Mars, there is a continued need for improved tire and vehicle development. When tires or vehicles are being designed for off-road conditions where significant thrust generation is required, such as climbing out of craters on the Moon, it is important to use a standard test method for evaluating their tractive performance. The drawbar pull (DP) test is a way of measuring the net thrust generated by tires or a vehicle with respect to performance metrics such as travel reduction, sinkage, or power efficiency. DP testing may be done using a single tire on a traction rig, or with a set of tires on a vehicle; this report focuses on vehicle DP tests. Though vehicle DP tests have been used for decades, there are no standard procedures that apply to exploration vehicles. This report summarizes previous methods employed, shows the sensitivity of certain test parameters, and provides a body of knowledge for developing standard testing procedures. The focus of this work is on lunar applications, but these test methods can be applied to terrestrial and planetary conditions as well. Section 1.0 of this report discusses the utility of DP testing for off-road vehicle evaluation and the metrics used. Section 2.0 focuses on test-terrain preparation, using the example case of lunar terrain. There is a review of lunar terrain analogs implemented in the past and a discussion on the lunar terrain conditions created at the NASA Glenn Research Center, including methods of evaluating the terrain strength variation and consistency from test to test. Section 3.0 provides details of the vehicle test procedures. These consist of a review of past methods, a comprehensive study on the sensitivity of test parameters, and a summary of the procedures used for DP testing at Glenn.
Comparison of different measurement methods for transmittance haze
NASA Astrophysics Data System (ADS)
Yu, Hsueh-Ling; Hsaio, Chin-Chai
2009-08-01
Transmittance haze is increasingly important to the LCD and solar cell industry. Most commercial haze measurement instruments are designed according to the method recommended in the documentary standards like ASTM D 1003 (ASTM 2003 Standard Test Method for Haze and Luminous Transmittance of Transparent Plastics), JIS K 7361 (JIS 1997 Plastics—Determination of the Total Luminous Transmittance of Transparent Materials—Part 1: Single Beam Instrument) and ISO 14782 (ISO 1997 Plastics—Determination of Haze of Transparent Materials). To improve the measurement accuracy of the current standards, a new apparatus was designed by the Center for Measurement Standards (Yu et al 2006 Meas. Sci. Technol. 17 N29-36). Besides the methods mentioned above, a double-beam method is used in the design of some instruments. There are discrepancies between the various methods. But no matter which method is used, a white standard is always needed. This paper compares the measurement results from different methods, presents the effect of the white standard, and analyses the measurement uncertainty.
Kwon, Jae-Sung; Kim, Kwang-Mahn; Kim, Kyoung-Nam
2014-10-01
The biocompatibility evaluation of nanomaterials is essential for their medical diagnostic and therapeutic usage, where a cytotoxicity test is the simplest form of biocompatibility evaluation. Three methods have been commonly used in previous studies for the cytotoxicity testing of nanomaterials: trypan blue exclusion, colorimetric assay using water soluble tetrazolium (WST), and imaging under a microscope following calcein AM/ethidium homodimer-1 staining. However, there has yet to be a study to compare each method. Therefore, in this study three methods were compared using the standard reference material of sodium lauryl sulfate (SLS). Each method of the cytotoxicity test was carried out using mouse fibroblasts of L-929 exposed to different concentrations of SLS. Compared to the gold standard trypan blue exclusion test, both colorimetric assay using water soluble tetrazolium (WST) and imaging under microscope with calcein AM/ethidium homodimer-1 staining showed results that were not statistically different. Also, each method exhibited various advantages and disadvantages, which included the need of equipment, time taken for the experiment, and provision of additional information such as cell morphology. Therefore, this study concludes that all three methods of cytotoxicity testing may be valid, though careful consideration will be needed when selecting tests with regard to time, finances, and the amount of information required by the researcher(s).
Analysis and elimination method of the effects of cables on LVRT testing for offshore wind turbines
NASA Astrophysics Data System (ADS)
Jiang, Zimin; Liu, Xiaohao; Li, Changgang; Liu, Yutian
2018-02-01
The current state, characteristics and necessity of the low voltage ride through (LVRT) on-site testing for grid-connected offshore wind turbines are introduced firstly. Then the effects of submarine cables on the LVRT testing are analysed based on the equivalent circuit of the testing system. A scheme for eliminating the effects of cables on the proposed LVRT testing method is presented. The specified voltage dips are guaranteed to be in compliance with the testing standards by adjusting the ratio between the current limiting impedance and short circuit impedance according to the steady voltage relationship derived from the equivalent circuit. Finally, simulation results demonstrate that the voltage dips at the high voltage side of wind turbine transformer satisfy the requirements of testing standards.
Testing of CMA-2000 Microwave Landing System (MLS) airborne receiver
NASA Astrophysics Data System (ADS)
Labreche, L.; Murfin, A. J.
1989-09-01
Microwave landing system (MLS) is a precision approach and landing guidance system which provides position information and various air to ground data. Position information is provided on a wide coverage sector and is determined by an azimuth angle measurement, an elevation angle measurement, and a range measurement. MLS performance standards and testing of the MLS airborne receiver is mainly governed by Technical Standard Order TSO-C104 issued by the Federal Aviation Administration. This TSO defines detailed test procedures for use in determining the required performance under standard and stressed conditions. It also imposes disciplines on software development and testing procedures. Testing performed on the CMA-2000 MLS receiver and methods used in its validation are described. A computer automated test system has been developed to test for compliance with RTCA/DO-177 Minimum Operation Performance Standards. Extensive software verification and traceability tests designed to ensure compliance with RTCA/DO-178 are outlined.
Achieving Innovation and Affordability Through Standardization of Materials Development and Testing
NASA Technical Reports Server (NTRS)
Bray, M. H.; Zook, L. M.; Raley, R. E.; Chapman, C.
2011-01-01
The successful expansion of development, innovation, and production within the aeronautics industry during the 20th century was facilitated by collaboration of government agencies with the commercial aviation companies. One of the initial products conceived from the collaboration was the ANC-5 Bulletin, first published in 1937. The ANC-5 Bulletin had intended to standardize the requirements of various government agencies in the design of aircraft structure. The national space policy shift in priority for NASA with an emphasis on transferring the travel to low earth orbit to commercial space providers highlights an opportunity and a need for the national and global space industries. The same collaboration and standardization that is documented and maintained by the industry within MIL-HDBK-5 (MMPDS-01) and MIL-HBDK-17 (nonmetallic mechanical properties) can also be exploited to standardize the thermal performance properties, processing methods, test methods, and analytical methods for use in aircraft and spacecraft design and associated propulsion systems. In addition to the definition of thermal performance description and standardization, the standardization for test methods and analysis for extreme environments (high temperature, cryogenics, deep space radiation, etc) would also be highly valuable to the industry. Its subsequent revisions and conversion to MIL-HDBK-5 and then MMPDS-01 established and then expanded to contain standardized mechanical property design values and other related design information for metallic materials used in aircraft, missiles, and space vehicles. It also includes guidance on standardization of composition, processing, and analytical methods for presentation and inclusion into the handbook. This standardization enabled an expansion of the technologies to provide efficiency and reliability to the consumers. It can be established that many individual programs within the government agencies have been overcome with development costs generated from these nonstandard requirements. Without industry standardization and acceptance, the programs are driven to shoulder the costs of determining design requirements, performance criteria, and then material qualification and certification. A significant investment that the industry could make to both reduce individual program development costs and schedules while expanding commercial space flight capabilities would be to invest in standardizing material performance properties for high temperature, cryogenic, and deep space environments for both metallic and nonmetallic materials.
PERFORMANCE OF A TWO-CYCLE REFRIGERATOR/FREEZER USING HFC REFRIGERANTS
A two-cycle 18 ft3 (0.51 m3) refrigerator/freezer (R/F) was tested utilizing American National Standards Institute (ANSI)/AHAM (1988) standards for energy consumption testing. A 34.9% energy consumption reduction was realized. This work presents a proven method of reducing the ...
Robust Confidence Interval for a Ratio of Standard Deviations
ERIC Educational Resources Information Center
Bonett, Douglas G.
2006-01-01
Comparing variability of test scores across alternate forms, test conditions, or subpopulations is a fundamental problem in psychometrics. A confidence interval for a ratio of standard deviations is proposed that performs as well as the classic method with normal distributions and performs dramatically better with nonnormal distributions. A simple…
Student Laptop Use and Scores on Standardized Tests
ERIC Educational Resources Information Center
Kposowa, Augustine J.; Valdez, Amanda D.
2013-01-01
Objectives: The primary objective of the study was to investigate the relationship between ubiquitous laptop use and academic achievement. It was hypothesized that students with ubiquitous laptops would score on average higher on standardized tests than those without such computers. Methods: Data were obtained from two sources. First, demographic…
Hoyer, Annika; Kuss, Oliver
2018-05-01
Meta-analysis of diagnostic studies is still a rapidly developing area of biostatistical research. Especially, there is an increasing interest in methods to compare different diagnostic tests to a common gold standard. Restricting to the case of two diagnostic tests, in these meta-analyses the parameters of interest are the differences of sensitivities and specificities (with their corresponding confidence intervals) between the two diagnostic tests while accounting for the various associations across single studies and between the two tests. We propose statistical models with a quadrivariate response (where sensitivity of test 1, specificity of test 1, sensitivity of test 2, and specificity of test 2 are the four responses) as a sensible approach to this task. Using a quadrivariate generalized linear mixed model naturally generalizes the common standard bivariate model of meta-analysis for a single diagnostic test. If information on several thresholds of the tests is available, the quadrivariate model can be further generalized to yield a comparison of full receiver operating characteristic (ROC) curves. We illustrate our model by an example where two screening methods for the diagnosis of type 2 diabetes are compared.
40 CFR 63.1064 - Alternative means of emission limitation.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Standards, Chapter 19, Section 3, Part A, Wind Tunnel Test Method for the Measurement of Deck-Fitting Loss... limitation. 63.1064 Section 63.1064 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... as wind, temperature, and barometric pressure. Test methods that can be used to perform the testing...
40 CFR 63.1064 - Alternative means of emission limitation.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Standards, Chapter 19, Section 3, Part A, Wind Tunnel Test Method for the Measurement of Deck-Fitting Loss... limitation. 63.1064 Section 63.1064 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... as wind, temperature, and barometric pressure. Test methods that can be used to perform the testing...
40 CFR 63.1064 - Alternative means of emission limitation.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Standards, Chapter 19, Section 3, Part A, Wind Tunnel Test Method for the Measurement of Deck-Fitting Loss... limitation. 63.1064 Section 63.1064 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... as wind, temperature, and barometric pressure. Test methods that can be used to perform the testing...
40 CFR 63.1064 - Alternative means of emission limitation.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Standards, Chapter 19, Section 3, Part A, Wind Tunnel Test Method for the Measurement of Deck-Fitting Loss... limitation. 63.1064 Section 63.1064 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... as wind, temperature, and barometric pressure. Test methods that can be used to perform the testing...
40 CFR 63.1064 - Alternative means of emission limitation.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Standards, Chapter 19, Section 3, Part A, Wind Tunnel Test Method for the Measurement of Deck-Fitting Loss... limitation. 63.1064 Section 63.1064 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... as wind, temperature, and barometric pressure. Test methods that can be used to perform the testing...
The U.S. Environmental Protection Agency has standardized methods for performing acute marine amphipod sediment toxicity tests. A test design reducing sediment volume from 200 to 50 ml and overlying water from 600 to 150 ml was recently proposed. An interlaboratory comparison wa...
40 CFR 60.704 - Test methods and procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Volatile Organic Compound Emissions From Synthetic Organic Chemical Manufacturing Industry (SOCMI) Reactor Processes § 60... compound j in ppm, as measured for organics by Method 18 and measured for hydrogen and carbon monoxide by...
40 CFR 60.704 - Test methods and procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Volatile Organic Compound Emissions From Synthetic Organic Chemical Manufacturing Industry (SOCMI) Reactor Processes § 60... basis of compound j in ppm, as measured for organics by Method 18 and measured for hydrogen and carbon...
NASA Astrophysics Data System (ADS)
Pfefer, Joshua; Agrawal, Anant
2012-03-01
In recent years there has been increasing interest in development of consensus, tissue-phantom-based approaches for assessment of biophotonic imaging systems, with the primary goal of facilitating clinical translation of novel optical technologies. Well-characterized test methods based on tissue phantoms can provide useful tools for performance assessment, thus enabling standardization and device inter-comparison during preclinical development as well as quality assurance and re-calibration in the clinical setting. In this review, we study the role of phantom-based test methods as described in consensus documents such as international standards for established imaging modalities including X-ray CT, MRI and ultrasound. Specifically, we focus on three image quality characteristics - spatial resolution, spatial measurement accuracy and image uniformity - and summarize the terminology, metrics, phantom design/construction approaches and measurement/analysis procedures used to assess these characteristics. Phantom approaches described are those in routine clinical use and tend to have simplified morphology and biologically-relevant physical parameters. Finally, we discuss the potential for applying knowledge gained from existing consensus documents in the development of standardized, phantom-based test methods for optical coherence tomography.
40 CFR 60.1790 - What test methods must I use to stack test?
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 6 2011-07-01 2011-07-01 false What test methods must I use to stack test? 60.1790 Section 60.1790 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emission Guidelines and Compliance Times for Small Municipal Waste...
40 CFR 60.1790 - What test methods must I use to stack test?
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 7 2012-07-01 2012-07-01 false What test methods must I use to stack test? 60.1790 Section 60.1790 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emission Guidelines and Compliance Times for Small Municipal Waste...
40 CFR 60.1790 - What test methods must I use to stack test?
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 7 2014-07-01 2014-07-01 false What test methods must I use to stack test? 60.1790 Section 60.1790 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emission Guidelines and Compliance Times for Small Municipal Waste...
40 CFR 63.2993 - What test methods must I use in conducting performance tests?
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 13 2013-07-01 2012-07-01 true What test methods must I use in conducting performance tests? 63.2993 Section 63.2993 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED) National Emissio...
40 CFR 60.1790 - What test methods must I use to stack test?
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 7 2013-07-01 2013-07-01 false What test methods must I use to stack test? 60.1790 Section 60.1790 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Emission Guidelines and Compliance Times for Small Municipal Waste...
NASA Technical Reports Server (NTRS)
Garrett, J. W.; Glassford, A. P. M.; Steakley, J. M.
1994-01-01
The American Society for Testing and Materials has published a new standard test method for characterizing time and temperature-dependence of material outgassing kinetics and the deposition kinetics of outgassed species on surfaces at various temperatures. This new ASTM standard, E 1559(1), uses the quartz crystal microbalance (QCM) collection measurement approach. The test method was originally developed under a program sponsored by the United States Air Force Materials Laboratory (AFML) to create a standard test method for obtaining outgassing and deposition kinetics data for spacecraft materials. Standardization by ASTM recognizes that the method has applications beyond aerospace. In particular, the method will provide data of use to the electronics, semiconductor, and high vacuum industries. In ASTM E 1559 the material sample is held in vacuum in a temperature-controlled effusion cell, while its outgassing flux impinges on several QCM's which view the orifice of the effusion cell. Sample isothermal total mass loss (TML) is measured as a function of time from the mass collected on one of the QCM's which is cooled by liquid nitrogen, and the view factor from this QCM to the cell. The amount of outgassed volatile condensable material (VCM) on surfaces at higher temperatures is measured as a function of time during the isothermal outgassing test by controlling the temperatures of the remaining QCM's to selected values. The VCM on surfaces at temperatures in between those of the collector QCM's is determined at the end of the isothermal test by heating the QCM's at a controlled rate and measuring the mass loss from the end of the QCM's as a function of time and temperature. This reevaporation of the deposit collected on the QCM's is referred to as QCM thermogravimetric analysis. Isothermal outgassing and deposition rates can be determined by differentiating the isothermal TML and VCM data, respectively, while the evaporation rates of the species can be obtained as a function of temperature by differentiating the QCM thermogravimetric analysis data.
A Modified Carbon Monoxide Breath Test for Measuring Erythrocyte Lifespan in Small Animals
Ma, Yong-Jian; Zhang, Hou-De; Ji, Yong-Qiang; Zhu, Guo-Liang; Huang, Jia-Liang; Du, Li-Tao; Cao, Ping; Zang, De-Yue; Du, Ji-Hui; Li, Rong; Wang, Lei
2016-01-01
This study was to develop a CO breath test for RBC lifespan estimation of small animals. The ribavirin induced hemolysis rabbit models were placed individually in a closed rebreath cage and air samples were collected for measurement of CO concentration. RBC lifespan was calculated from accumulated CO, blood volume, and hemoglobin concentration data. RBC lifespan was determined in the same animals with the standard biotin-labeling method. RBC lifespan data obtained by the CO breath test method for control (CON, 49.0 ± 5.9 d) rabbits, rabbits given 10 mg/kg·d−1 of ribavirin (RIB10, 31.0 ± 4.0 d), and rabbits given 20 mg/kg·d−1 of ribavirin (RIB20, 25.0 ± 2.9 d) were statistically similar (all p > 0.05) to and linearly correlated (r = 0.96, p < 0.01) with the RBC lifespan data obtained for the same rabbits by the standard biotin-labeling method (CON, 51.0 ± 2.7 d; RIB10, 33.0 ± 1.3 d; and RIB20, 27.0 ± 0.8 d). The CO breath test method takes less than 3 h to complete, whereas the standard method requires at least several weeks. In conclusion, the CO breath test method provides a simple and rapid means of estimating RBC lifespan and is feasible for use with small animal models. PMID:27294128
Mäkelä, Erja A; Vainiotalo, Sinikka; Peltonen, Kimmo
2003-06-01
Standard test methods ASTM F739 and EN 374 were compared by assessing the permeation of 70% isopropyl alcohol (2-propanol) through seven brands of surgical gloves. The two standards differ in the flow rates of the collection medium and in the chemical permeation rate at which the breakthrough time (BTT) is detected, the EN detection level being 10 times higher than the permeation rate used by ASTM. In a departure from the EN standard method, a 4 h testing time was used instead of 8 h. All of the tested gloves were from the same manufacturer and were made from either natural rubber (NR) (six brands) or chloroprene rubber (CR) (one brand). Two of the NR glove brands were double layered. For the thin NR gloves (0.22, 0.28 and 0.27 mm) the permeation rates were higher throughout the tests with a flow rate of 474 ml/min (EN) of the collection medium (nitrogen) compared with the permeation rates obtained with a flow rate of 52 ml/min (ASTM). These resulted in BTTs of 4.6, 6.5 and 7.6 min (EN) and 4.8, 6.5 and 9.1 min (ASTM), respectively. No statistical difference could be observed between the BTT values obtained with the two standard methods for any of the thin gloves. Thus, although the ASTM standard has a lower criterion for the detection of permeation, it does not necessarily produce shorter BTTs. For the better barriers the methods yielded more equivalent permeation rate curves and thus the EN BTTs were longer than the ASTM BTTs: the EN results were 21, 80, 122 and >240 min compared with the ASTM results of 12, 32, 38 and 103 min for glove thicknesses of 0.37 (NR), 0.22 + 0.22 (double layered NR), 0.31 + 0.29 (double layered NR) and 0.19 mm (CR), respectively.
Below-Ambient and Cryogenic Thermal Testing
NASA Technical Reports Server (NTRS)
Fesmire, James E.
2016-01-01
Thermal insulation systems operating in below-ambient temperature conditions are inherently susceptible to moisture intrusion and vapor drive toward the cold side. The subsequent effects may include condensation, icing, cracking, corrosion, and other problems. Methods and apparatus for real-world thermal performance testing of below-ambient systems have been developed based on cryogenic boiloff calorimetry. New ASTM International standards on cryogenic testing and their extension to future standards for below-ambient testing of pipe insulation are reviewed.
ASTM Validates Air Pollution Test Methods
ERIC Educational Resources Information Center
Chemical and Engineering News, 1973
1973-01-01
The American Society for Testing and Materials (ASTM) has validated six basic methods for measuring pollutants in ambient air as the first part of its Project Threshold. Aim of the project is to establish nationwide consistency in measuring pollutants; determining precision, accuracy and reproducibility of 35 standard measuring methods. (BL)
Comparison of RFFIT tests with different standard sera and testing procedures.
Yu, Peng-cheng; Noguchi, Akira; Inoue, Satoshi; Tang, Qing; Rayner, Simon; Liang, Guo-dong
2012-06-01
The World Health Organization (WHO) standard assay for determining antibody level is the rapid fluorescent focus inhibition test (RFFIT) and is used to determine the degree of immunity after vaccination against rabies. To compare the difference in RFFIT results between the laboratories of The National Institute of Infectious Disease in Japan (NIID) and the Chinese Centre for Disease Control (CCDC) as well the influence of the choice of standard serum (STD) for the detection, the two laboratories detection methods were simultaneously manipulated by RFFIT. The reference serums used in NIID and the WHO standard serum used in CCDC were compared in the same RFFIT detection to determine the titer of four sera samples C1, S1, S2 and S4 in parallel, and the titers of the detected sera samples were calculated using the standard formula for neutralizing antibody titer. No significant difference was found in RFFIT methods from the two laboratories and the RFFIT testing procedures of the two laboratories have good consistency. However, different titers were obtained with the tentative internal standard serum (TI-STD) produced by adjusting to 2.0 IU of WHO standard serum in NIID and the WHO STD. The titer determined with the TI-STD was higher than that determined with WHO STD, This difference appears to be significant and requires further investigation.
Integrated Data Collection Analysis (IDCA) Program - SSST Testing Methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandstrom, Mary M.; Brown, Geoffrey W.; Preston, Daniel N.
The Integrated Data Collection Analysis (IDCA) program is conducting a proficiency study for Small- Scale Safety and Thermal (SSST) testing of homemade explosives (HMEs). Described here are the methods used for impact, friction, electrostatic discharge, and differential scanning calorimetry analysis during the IDCA program. These methods changed throughout the Proficiency Test and the reasons for these changes are documented in this report. The most significant modifications in standard testing methods are: 1) including one specified sandpaper in impact testing among all the participants, 2) diversifying liquid test methods for selected participants, and 3) including sealed sample holders for thermal testingmore » by at least one participant. This effort, funded by the Department of Homeland Security (DHS), is putting the issues of safe handling of these materials in perspective with standard military explosives. The study is adding SSST testing results for a broad suite of different HMEs to the literature. Ultimately the study will suggest new guidelines and methods and possibly establish the SSST testing accuracies needed to develop safe handling practices for HMEs. Each participating testing laboratory uses identical test materials and preparation methods wherever possible. The testing performers involved are Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Indian Head Division, Naval Surface Warfare Center, (NSWC IHD), Sandia National Laboratories (SNL), and Air Force Research Laboratory (AFRL/RXQL). These tests are conducted as a proficiency study in order to establish some consistency in test protocols, procedures, and experiments and to compare results when these testing variables cannot be made consistent.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-09
... sometimes approves a rule only as a SIP strengthening action (e.g., to update definitions, add test methods... standards (e.g., materials specifications, test methods, sampling procedures, and business practices) that...
Effectiveness of Cool Roof Coatings with Ceramic Particles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brehob, Ellen G; Desjarlais, Andre Omer; Atchley, Jerald Allen
2011-01-01
Liquid applied coatings promoted as cool roof coatings, including several with ceramic particles, were tested at Oak Ridge National Laboratory (ORNL), Oak Ridge, Tenn., for the purpose of quantifying their thermal performances. Solar reflectance measurements were made for new samples and aged samples using a portable reflectometer (ASTM C1549, Standard Test Method for Determination of Solar Reflectance Near Ambient Temperature Using a Portable Solar Reflectometer) and for new samples using the integrating spheres method (ASTM E903, Standard Test Method for Solar Absorptance, Reflectance, and Transmittance of Materials Using Integrating Spheres). Thermal emittance was measured for the new samples using amore » portable emissometer (ASTM C1371, Standard Test Method for Determination of Emittance of Materials Near Room 1 Proceedings of the 2011 International Roofing Symposium Temperature Using Portable Emissometers). Thermal conductivity of the coatings was measured using a FOX 304 heat flow meter (ASTM C518, Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus). The surface properties of the cool roof coatings had higher solar reflectance than the reference black and white material, but there were no significant differences among coatings with and without ceramics. The coatings were applied to EPDM (ethylene propylene diene monomer) membranes and installed on the Roof Thermal Research Apparatus (RTRA), an instrumented facility at ORNL for testing roofs. Roof temperatures and heat flux through the roof were obtained for a year of exposure in east Tennessee. The field tests showed significant reduction in cooling required compared with the black reference roof (~80 percent) and a modest reduction in cooling compared with the white reference roof (~33 percent). The coating material with the highest solar reflectivity (no ceramic particles) demonstrated the best overall thermal performance (combination of reducing the cooling load cost and not incurring a large heating penalty cost) and suggests solar reflectivity is the significant characteristic for selecting cool roof coatings.« less
COMPARISON OF DIFFERENT TRUNK ENDURANCE TESTING METHODS IN COLLEGE‐AGED INDIVIDUALS
Krier, Amber D.; Nelson, Julie A.; Rogers, Michael A.; Stuke, Zachariah O.; Smith, Barbara S.
2012-01-01
Objective: Determine the reliability of two different modified (MOD1 and MOD2) testing methods compared to a standard method (ST) for testing trunk flexion and extension endurance. Participants: Twenty‐eight healthy individuals (age 26.4 ± 3.2 years, height 1.75 ± m, weight 71.8 ± 10.3 kg, body mass index 23.6 ± 3.4 m/kg2). Method: Trunk endurance time was measured in seconds for flexion and extension under the three different stabilization conditions. The MOD1 testing procedure utilized a female clinician (70.3 kg) and MOD2 utilized a male clinician (90.7 kg) to provide stabilization as opposed to the ST method of belt stabilization. Results: No significant differences occurred between flexion and extension times. Intraclass correlations (ICCs3,1) for the different testing conditions ranged from .79 to .95 (p <.000) and are found in Table 3. Concurrent validity using the ST flexion times as the gold standard coefficients were .95 for MOD1 and .90 for MOD2. For ST extension, coefficients were .91 and .80, for MOD1 and MOD2 respectively (p <.01). Conclusions: These methods proved to be a reliable substitute for previously accepted ST testing methods in normal college‐aged individuals. These modified testing procedures can be implemented in athletic training rooms and weight rooms lacking appropriate tables for the ST testing. Level of Evidence: 3 PMID:23091786
ERIC Educational Resources Information Center
Frisby, Craig L.; Wang, Ze
2016-01-01
Data from the standardization sample of the Woodcock-Johnson Psychoeducational Battery--Third Edition (WJ III) Cognitive standard battery and Test Session Observation Checklist items were analyzed to understand the relationship between g (general mental ability) and test session behavior (TSB; n = 5,769). Latent variable modeling methods were used…
ERIC Educational Resources Information Center
Cui, Zhongmin; Kolen, Michael J.
2008-01-01
This article considers two methods of estimating standard errors of equipercentile equating: the parametric bootstrap method and the nonparametric bootstrap method. Using a simulation study, these two methods are compared under three sample sizes (300, 1,000, and 3,000), for two test content areas (the Iowa Tests of Basic Skills Maps and Diagrams…
Method and platform standardization in MRM-based quantitative plasma proteomics.
Percy, Andrew J; Chambers, Andrew G; Yang, Juncong; Jackson, Angela M; Domanski, Dominik; Burkhart, Julia; Sickmann, Albert; Borchers, Christoph H
2013-12-16
There exists a growing demand in the proteomics community to standardize experimental methods and liquid chromatography-mass spectrometry (LC/MS) platforms in order to enable the acquisition of more precise and accurate quantitative data. This necessity is heightened by the evolving trend of verifying and validating candidate disease biomarkers in complex biofluids, such as blood plasma, through targeted multiple reaction monitoring (MRM)-based approaches with stable isotope-labeled standards (SIS). Considering the lack of performance standards for quantitative plasma proteomics, we previously developed two reference kits to evaluate the MRM with SIS peptide approach using undepleted and non-enriched human plasma. The first kit tests the effectiveness of the LC/MRM-MS platform (kit #1), while the second evaluates the performance of an entire analytical workflow (kit #2). Here, these kits have been refined for practical use and then evaluated through intra- and inter-laboratory testing on 6 common LC/MS platforms. For an identical panel of 22 plasma proteins, similar concentrations were determined, regardless of the kit, instrument platform, and laboratory of analysis. These results demonstrate the value of the kit and reinforce the utility of standardized methods and protocols. The proteomics community needs standardized experimental protocols and quality control methods in order to improve the reproducibility of MS-based quantitative data. This need is heightened by the evolving trend for MRM-based validation of proposed disease biomarkers in complex biofluids such as blood plasma. We have developed two kits to assist in the inter- and intra-laboratory quality control of MRM experiments: the first kit tests the effectiveness of the LC/MRM-MS platform (kit #1), while the second evaluates the performance of an entire analytical workflow (kit #2). In this paper, we report the use of these kits in intra- and inter-laboratory testing on 6 common LC/MS platforms. This article is part of a Special Issue entitled: Standardization and Quality Control in Proteomics. © 2013.
40 CFR 60.285 - Test methods and procedures.
Code of Federal Regulations, 2013 CFR
2013-07-01
... determine compliance with the particulate matter standards in § 60.282(a) (1) and (3) as follows: (1) Method 5 shall be used to determine the particulate matter concentration. The sampling time and sample... opacity. (c) The owner or operator shall determine compliance with the particular matter standard in § 60...
40 CFR 60.285 - Test methods and procedures.
Code of Federal Regulations, 2014 CFR
2014-07-01
... determine compliance with the particulate matter standards in § 60.282(a) (1) and (3) as follows: (1) Method 5 shall be used to determine the particulate matter concentration. The sampling time and sample... opacity. (c) The owner or operator shall determine compliance with the particular matter standard in § 60...
40 CFR 60.285 - Test methods and procedures.
Code of Federal Regulations, 2012 CFR
2012-07-01
... determine compliance with the particulate matter standards in § 60.282(a) (1) and (3) as follows: (1) Method 5 shall be used to determine the particulate matter concentration. The sampling time and sample... opacity. (c) The owner or operator shall determine compliance with the particular matter standard in § 60...
40 CFR 60.285 - Test methods and procedures.
Code of Federal Regulations, 2011 CFR
2011-07-01
... determine compliance with the particulate matter standards in § 60.282(a) (1) and (3) as follows: (1) Method 5 shall be used to determine the particulate matter concentration. The sampling time and sample... opacity. (c) The owner or operator shall determine compliance with the particular matter standard in § 60...
Katoh, Masakazu; Hamajima, Fumiyasu; Ogasawara, Takahiro; Hata, Ken-Ichiro
2009-06-01
A validation study of an in vitro skin irritation testing method using a reconstructed human skin model has been conducted by the European Centre for the Validation of Alternative Methods (ECVAM), and a protocol using EpiSkin (SkinEthic, France) has been approved. The structural and performance criteria of skin models for testing are defined in the ECVAM Performance Standards announced along with the approval. We have performed several evaluations of the new reconstructed human epidermal model LabCyte EPI-MODEL, and confirmed that it is applicable to skin irritation testing as defined in the ECVAM Performance Standards. We selected 19 materials (nine irritants and ten non-irritants) available in Japan as test chemicals among the 20 reference chemicals described in the ECVAM Performance Standard. A test chemical was applied to the surface of the LabCyte EPI-MODEL for 15 min, after which it was completely removed and the model then post-incubated for 42 hr. Cell v iability was measured by MTT assay and skin irritancy of the test chemical evaluated. In addition, interleukin-1 alpha (IL-1alpha) concentration in the culture supernatant after post-incubation was measured to provide a complementary evaluation of skin irritation. Evaluation of the 19 test chemicals resulted in 79% accuracy, 78% sensitivity and 80% specificity, confirming that the in vitro skin irritancy of the LabCyte EPI-MODEL correlates highly with in vivo skin irritation. These results suggest that LabCyte EPI-MODEL is applicable to the skin irritation testing protocol set out in the ECVAM Performance Standards.
2016-09-01
Standardization (ISO). 2015. Water quality - calanoid copepod early- life stage test with Acartia tonsa. ISO 16778:2015. International Organization for...Toxicity Test Methods for Marine Water Quality Evaluations by Alan J Kennedy, Guilherme Lotufo, Jennifer G. Laird, and J. Daniel Farrar PURPOSE: The...MPRSA evaluations in some regions. The organisms used in these test methods are not planktonic for most of their life cycles (juveniles and adults
Developing product quality standards for wheelchairs used in less-resourced environments
McCambridge, Matt; Reese, Norman; Schoendorfer, Don; Wunderlich, Eric; Rushman, Chris; Mahilo, Dave
2017-01-01
Background Premature failures of wheelchairs in less-resourced environments (LREs) may be because of shortcomings in product regulation and quality standards. The standards published by the International Organization for Standardization (ISO) specify wheelchair tests for durability, safety and performance, but their applicability to products used in the rugged conditions of LREs is unclear. Because of this, wheelchair-related guidelines published by the World Health Organization recommended developing more rigorous durability tests for wheelchairs. Objectives This study was performed to identify the additional tests needed for LREs. Methods First, a literature review of the development of ISO test standards, wheelchair standards testing studies and wheelchair evaluations in LREs was performed. Second, expert advice from members of the Standards Working Group of the International Society of Wheelchair Professionals (ISWP) was compiled and reviewed. Results A total of 35 articles were included in the literature review. Participation from LREs was not observed in the ISO standards development. As per wheelchair testing study evidence, wheelchair models delivered in LREs did not meet the minimum standards requirement. Multiple part failures and repairs were observed with reviewed field evaluation studies. ISWP experts noted that several testing factors responsible for premature failures with wheelchair parts are not included in the standards and accordingly provided advice for additional test development. Conclusion The study findings indicate the need to develop a wide range of tests, with specific tests for measuring corrosion resistance of the entire wheelchair, rolling resistance of castors and rear wheels, and durability of whole wheelchair and castor assemblies. PMID:28936410
Testing the statistical compatibility of independent data sets
NASA Astrophysics Data System (ADS)
Maltoni, M.; Schwetz, T.
2003-08-01
We discuss a goodness-of-fit method which tests the compatibility between statistically independent data sets. The method gives sensible results even in cases where the χ2 minima of the individual data sets are very low or when several parameters are fitted to a large number of data points. In particular, it avoids the problem that a possible disagreement between data sets becomes diluted by data points which are insensitive to the crucial parameters. A formal derivation of the probability distribution function for the proposed test statistics is given, based on standard theorems of statistics. The application of the method is illustrated on data from neutrino oscillation experiments, and its complementarity to the standard goodness-of-fit is discussed.
Oromucosal film preparations: classification and characterization methods.
Preis, Maren; Woertz, Christina; Kleinebudde, Peter; Breitkreutz, Jörg
2013-09-01
Recently, the regulatory authorities have enlarged the variety of 'oromucosal preparations' by buccal films and orodispersible films. Various film preparations have entered the market and pharmacopoeias. Due to the novelty of the official monographs, no standardized characterization methods and quality specifications are included. This review reports the methods of choice to characterize oromucosal film preparations with respect to biorelevant characterization and quality control. Commonly used dissolution tests for other dosage forms are not transferable for films in all cases. Alternatives and guidance on decision, which methods are favorable for film preparations are discussed. Furthermore, issues about requirements for film dosage forms are reflected. Oromucosal film preparations offer a wide spectrum of opportunities. There are a lot of suggestions in the literature on how to control the quality of these innovative products, but no standardized tests are available. Regulatory authorities need to define the standards and quality requirements more precisely.
Development of Gold Standard Ion-Selective Electrode-Based Methods for Fluoride Analysis
Martínez-Mier, E.A.; Cury, J.A.; Heilman, J.R.; Katz, B.P.; Levy, S.M.; Li, Y.; Maguire, A.; Margineda, J.; O’Mullane, D.; Phantumvanit, P.; Soto-Rojas, A.E.; Stookey, G.K.; Villa, A.; Wefel, J.S.; Whelton, H.; Whitford, G.M.; Zero, D.T.; Zhang, W.; Zohouri, V.
2011-01-01
Background/Aims: Currently available techniques for fluoride analysis are not standardized. Therefore, this study was designed to develop standardized methods for analyzing fluoride in biological and nonbiological samples used for dental research. Methods A group of nine laboratories analyzed a set of standardized samples for fluoride concentration using their own methods. The group then reviewed existing analytical techniques for fluoride analysis, identified inconsistencies in the use of these techniques and conducted testing to resolve differences. Based on the results of the testing undertaken to define the best approaches for the analysis, the group developed recommendations for direct and microdiffusion methods using the fluoride ion-selective electrode. Results Initial results demonstrated that there was no consensus regarding the choice of analytical techniques for different types of samples. Although for several types of samples, the results of the fluoride analyses were similar among some laboratories, greater differences were observed for saliva, food and beverage samples. In spite of these initial differences, precise and true values of fluoride concentration, as well as smaller differences between laboratories, were obtained once the standardized methodologies were used. Intraclass correlation coefficients ranged from 0.90 to 0.93, for the analysis of a certified reference material, using the standardized methodologies. Conclusion The results of this study demonstrate that the development and use of standardized protocols for F analysis significantly decreased differences among laboratories and resulted in more precise and true values. PMID:21160184
Instructional Practices: A Qualitative Study on the Response to Common Core Standardized Testing
ERIC Educational Resources Information Center
Hightower, Gabrielle
2017-01-01
The purpose of this qualitative study was to examine the instructional practices implemented by Tennessee elementary teachers in response to Common Core Standardized Testing. This research study utilized a basic qualitative method that included a purposive and convenient sampling. This qualitative study focused on face-to-face interviews, phone…
40 CFR 94.5 - Reference materials.
Code of Federal Regulations, 2010 CFR
2010-07-01
.../code_of_federal_regulations/ibr_locations.html. (a) ASTM material. Table 1 of § 94.5 lists material... of § 94.5—ASTM Materials Document No. and name Part 94 reference ASTM D 86-01, Standard Test Method for Distillation of Petroleum Products at Atmospheric Pressure 94.108 ASTM D 93-02, Standard Test...
Low, Ariana; Kok, Si Ling; Khong, Yuetmei; Chan, Sui Yung; Gokhale, Rajeev
2015-11-01
No standard time or pharmacopoeia disintegration test method for orodispersible films (ODFs) exists. The USP disintegration test for tablets and capsules poses significant challenges for end-point determination when used for ODFs. We tested a newly developed disintegration test unit (DTU) against the USP disintegration test. The DTU is an accessory to the USP disintegration apparatus. It holds the ODF in a horizontal position, allowing top-view of the ODF during testing. A Gauge R&R study was conducted to assign relative contributions of the total variability from the operator, sample or the experimental set-up. Precision was compared using commercial ODF products in different media. Agreement between the two measurement methods was analysed. The DTU showed improved repeatability and reproducibility compared to the USP disintegration system with tighter standard deviations regardless of operator or medium. There is good agreement between the two methods, with the USP disintegration test giving generally longer disintegration times possibly due to difficulty in end-point determination. The DTU provided clear end-point determination and is suitable for quality control of ODFs during product developmental stage or manufacturing. This may facilitate the development of a standardized methodology for disintegration time determination of ODFs. © 2015 Wiley Periodicals, Inc. and the American Pharmacists Association J Pharm Sci 104:3893-3903, 2015. Copyright © 2015 Wiley Periodicals, Inc. and the American Pharmacists Association.
Electrostatic Evaluation: SCAPE Suit Materials
NASA Technical Reports Server (NTRS)
Buhler, Charles; Calle, Carlos
2005-01-01
The surface resistivity tests are performed per the requirements of the ESD Association Standard Test Method ESD STM11.11*. These measurements are taken using a PRS-801 resistance system with an Electro Tech System (ETS) PRF-911 concentric ring resistance probe. The tests require a five pound weight on top of cylindrical electrodes and were conducted at both ambient and low humidity conditions. In order for materials to "pass" resistivity tests the surface of the materials must either be conductive or statically dissipative otherwise the materials "fail" ESD. Volume resistivity tests are also conducted to measure conductivity through the material as opposed to conductivity along the surface. These tests are conducted using the same PRS-801 resistance system with the Electro Tech System PRF-911 concentric ring resistance probe but are performed in accordance with ESD Association Standard Test Method ESD STM11.l2**.
Simplified three microphone acoustic test method
USDA-ARS?s Scientific Manuscript database
Accepted acoustic testing standards are available; however, they require specialized hardware and software that are typically out of reach economically to the occasional practitioner. What is needed is a simple and inexpensive screening method that could provide a quick comparison for rapid identifi...
ANALYSIS OF ALDEHYDES AND KETONES IN THE GAS PHASE
The development and testing of a 2,4-dinitrophenylhydrazine-acetonitrile (DNPH-ACN) method for the analysis of aldehydes and ketones in ambient air are described. A discussion of interferences, preparation of calibration standards, analytical testing, fluorescence methods and car...
Hypothesis Testing Using Factor Score Regression
Devlieger, Ines; Mayer, Axel; Rosseel, Yves
2015-01-01
In this article, an overview is given of four methods to perform factor score regression (FSR), namely regression FSR, Bartlett FSR, the bias avoiding method of Skrondal and Laake, and the bias correcting method of Croon. The bias correcting method is extended to include a reliable standard error. The four methods are compared with each other and with structural equation modeling (SEM) by using analytic calculations and two Monte Carlo simulation studies to examine their finite sample characteristics. Several performance criteria are used, such as the bias using the unstandardized and standardized parameterization, efficiency, mean square error, standard error bias, type I error rate, and power. The results show that the bias correcting method, with the newly developed standard error, is the only suitable alternative for SEM. While it has a higher standard error bias than SEM, it has a comparable bias, efficiency, mean square error, power, and type I error rate. PMID:29795886
Caudle, Kelly E.; Dunnenberger, Henry M.; Freimuth, Robert R.; Peterson, Josh F.; Burlison, Jonathan D.; Whirl-Carrillo, Michelle; Scott, Stuart A.; Rehm, Heidi L.; Williams, Marc S.; Klein, Teri E.; Relling, Mary V.; Hoffman, James M.
2017-01-01
Introduction: Reporting and sharing pharmacogenetic test results across clinical laboratories and electronic health records is a crucial step toward the implementation of clinical pharmacogenetics, but allele function and phenotype terms are not standardized. Our goal was to develop terms that can be broadly applied to characterize pharmacogenetic allele function and inferred phenotypes. Materials and methods: Terms currently used by genetic testing laboratories and in the literature were identified. The Clinical Pharmacogenetics Implementation Consortium (CPIC) used the Delphi method to obtain a consensus and agree on uniform terms among pharmacogenetic experts. Results: Experts with diverse involvement in at least one area of pharmacogenetics (clinicians, researchers, genetic testing laboratorians, pharmacogenetics implementers, and clinical informaticians; n = 58) participated. After completion of five surveys, a consensus (>70%) was reached with 90% of experts agreeing to the final sets of pharmacogenetic terms. Discussion: The proposed standardized pharmacogenetic terms will improve the understanding and interpretation of pharmacogenetic tests and reduce confusion by maintaining consistent nomenclature. These standard terms can also facilitate pharmacogenetic data sharing across diverse electronic health care record systems with clinical decision support. Genet Med 19 2, 215–223. PMID:27441996
Standard methods have been established by USEPA, ASTM International, Environment Canada and Organization for Economic Cooperation and Development for conducting sediment toxicity tests with various species of midges including Chironomus dilutus. Short-term 10-day exposures are ty...
NASA Technical Reports Server (NTRS)
Hughes, William O.; McNelis, Anne M.; Chris Nottoli; Eric Wolfram
2015-01-01
The absorption coefficient for material specimens are needed to quantify the expected acoustic performance of that material in its actual usage and environment. The ASTM C423-09a standard, "Standard Test Method for Sound Absorption and Sound Absorption Coefficients by the Reverberant Room Method" is often used to measure the absorption coefficient of material test specimens. This method has its basics in the Sabine formula. Although widely used, the interpretation of these measurements are a topic of interest. For example, in certain cases the measured Sabine absorption coefficients are greater than 1.0 for highly absorptive materials. This is often attributed to the diffraction edge effect phenomenon. An investigative test program to measure the absorption properties of highly absorbent melamine foam has been performed at the Riverbank Acoustical Laboratories. This paper will present and discuss the test results relating to the effect of the test materials' surface area, thickness and edge sealing conditions. A follow-on paper is envisioned that will present and discuss the results relating to the spacing between multiple piece specimens, and the mounting condition of the test specimen.
Marine Structural Steel Toughness Data Bank (Abridged Edition)
1990-08-31
for Table Column Headings: Break? Did specimen fracture completely? CODIc Critical COD CODi Initial COD CVN Energy Charpy V Energy Crack lgth Crack...Standard Y ear ........ .................. * Onen Test Temp KQ CODi CODIc Curve 3l degF ksi*in**0.5 mils mils in-lb/in2 L-T -166...Standard Method .... BS5762 -Standard Year . Test Temp CODIc degC mm -30 0.57 -30 0.68 -30 11.26 (continued) -not reported
Electrostatic testing of thin plastic materials
NASA Technical Reports Server (NTRS)
Skinner, S. Ballou
1988-01-01
Ten thin plastic materials (Velostat, RCAS 1200, Llumalloy, Herculite 80, RCAS 2400, Wrightlon 7000, PVC, Aclar 22A, Mylar, and Polyethylene) were tested for electrostatic properties by four different devices: (1) The static decay meter, (2) the manual triboelectric testing device, (3) the robotic triboelectric testing device, and (4) the resistivity measurement adapter device. The static decay meter measured the electrostatic decay rates in accordance with the Federal Test Method Standard 101B, Method 4046. The manual and the robotic triboelectric devices measured the triboelectric generated peak voltages and the five-second decay voltages in accordance with the criteria for acceptance standards at Kennedy Space Center. The resistivity measurement adapter measured the surface resistivity of each material. An analysis was made to correlate the data among the four testing devices. For the material tested the pass/fail results were compared for the 4046 method and the triboelectric testing devices. For the limited number of materials tested, the relationship between decay rate and surface resistivity was investigated as well as the relationship between triboelectric peak voltage and surface resistivity.
Measuring Thermal Conductivity at LH2 Temperatures
NASA Technical Reports Server (NTRS)
Selvidge, Shawn; Watwood, Michael C.
2004-01-01
For many years, the National Institute of Standards and Technology (NIST) produced reference materials for materials testing. One such reference material was intended for use with a guarded hot plate apparatus designed to meet the requirements of ASTM C177-97, "Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded-Hot-Plate Apparatus." This apparatus can be used to test materials in various gaseous environments from atmospheric pressure to a vacuum. It allows the thermal transmission properties of insulating materials to be measured from just above ambient temperature down to temperatures below liquid hydrogen. However, NIST did not generate data below 77 K temperature for the reference material in question. This paper describes a test method used at NASA's Marshall Space Flight Center (MSFC) to optimize thermal conductivity measurements during the development of thermal protection systems. The test method extends the usability range of this reference material by generating data at temperatures lower than 77 K. Information provided by this test is discussed, as are the capabilities of the MSFC Hydrogen Test Facility, where advanced methods for materials testing are routinely developed and optimized in support of aerospace applications.
Comparison of two methods of standard setting: the performance of the three-level Angoff method.
Jalili, Mohammad; Hejri, Sara M; Norcini, John J
2011-12-01
Cut-scores, reliability and validity vary among standard-setting methods. The modified Angoff method (MA) is a well-known standard-setting procedure, but the three-level Angoff approach (TLA), a recent modification, has not been extensively evaluated. This study aimed to compare standards and pass rates in an objective structured clinical examination (OSCE) obtained using two methods of standard setting with discussion and reality checking, and to assess the reliability and validity of each method. A sample of 105 medical students participated in a 14-station OSCE. Fourteen and 10 faculty members took part in the MA and TLA procedures, respectively. In the MA, judges estimated the probability that a borderline student would pass each station. In the TLA, judges estimated whether a borderline examinee would perform the task correctly or not. Having given individual ratings, judges discussed their decisions. One week after the examination, the procedure was repeated using normative data. The mean score for the total test was 54.11% (standard deviation: 8.80%). The MA cut-scores for the total test were 49.66% and 51.52% after discussion and reality checking, respectively (the consequent percentages of passing students were 65.7% and 58.1%, respectively). The TLA yielded mean pass scores of 53.92% and 63.09% after discussion and reality checking, respectively (rates of passing candidates were 44.8% and 12.4%, respectively). Compared with the TLA, the MA showed higher agreement between judges (0.94 versus 0.81) and a narrower 95% confidence interval in standards (3.22 versus 11.29). The MA seems a more credible and reliable procedure with which to set standards for an OSCE than does the TLA, especially when a reality check is applied. © Blackwell Publishing Ltd 2011.
A novel Python program for implementation of quality control in the ELISA.
Wetzel, Hanna N; Cohen, Cinder; Norman, Andrew B; Webster, Rose P
2017-09-01
The use of semi-quantitative assays such as the enzyme-linked immunosorbent assay (ELISA) requires stringent quality control of the data. However, such quality control is often lacking in academic settings due to unavailability of software and knowledge. Therefore, our aim was to develop methods to easily implement Levey-Jennings quality control methods. For this purpose, we created a program written in Python (a programming language with an open-source license) and tested it using a training set of ELISA standard curves quantifying the Fab fragment of an anti-cocaine monoclonal antibody in mouse blood. A colorimetric ELISA was developed using a goat anti-human anti-Fab capture method. Mouse blood samples spiked with the Fab fragment were tested against a standard curve of known concentrations of Fab fragment in buffer over a period of 133days stored at 4°C to assess stability of the Fab fragment and to generate a test dataset to assess the program. All standard curves were analyzed using our program to batch process the data and to generate Levey-Jennings control charts and statistics regarding the datasets. The program was able to identify values outside of two standard deviations, and this identification of outliers was consistent with the results of a two-way ANOVA. This program is freely available, which will help laboratories implement quality control methods, thus improving reproducibility within and between labs. We report here successful testing of the program with our training set and development of a method for quantification of the Fab fragment in mouse blood. Copyright © 2017 Elsevier B.V. All rights reserved.
Hui, Gabriel W. K.
1971-01-01
Modification of the Microtiter reading mirror used in the standardized diagnostic complement fixation method permits convenient estimation of the results in per cent hemolysis by direct visual comparison with the hemolytic standards. Images PMID:5564678
40 CFR 160.35 - Quality assurance unit.
Code of Federal Regulations, 2012 CFR
2012-07-01
... standard operating procedures were made without proper authorization and documentation. (6) Review the final study report to assure that such report accurately describes the methods and standard operating... LABORATORY PRACTICE STANDARDS Organization and Personnel § 160.35 Quality assurance unit. (a) A testing...
40 CFR 160.35 - Quality assurance unit.
Code of Federal Regulations, 2010 CFR
2010-07-01
... standard operating procedures were made without proper authorization and documentation. (6) Review the final study report to assure that such report accurately describes the methods and standard operating... LABORATORY PRACTICE STANDARDS Organization and Personnel § 160.35 Quality assurance unit. (a) A testing...
40 CFR 160.35 - Quality assurance unit.
Code of Federal Regulations, 2014 CFR
2014-07-01
... standard operating procedures were made without proper authorization and documentation. (6) Review the final study report to assure that such report accurately describes the methods and standard operating... LABORATORY PRACTICE STANDARDS Organization and Personnel § 160.35 Quality assurance unit. (a) A testing...
40 CFR 160.35 - Quality assurance unit.
Code of Federal Regulations, 2013 CFR
2013-07-01
... standard operating procedures were made without proper authorization and documentation. (6) Review the final study report to assure that such report accurately describes the methods and standard operating... LABORATORY PRACTICE STANDARDS Organization and Personnel § 160.35 Quality assurance unit. (a) A testing...
40 CFR 160.35 - Quality assurance unit.
Code of Federal Regulations, 2011 CFR
2011-07-01
... standard operating procedures were made without proper authorization and documentation. (6) Review the final study report to assure that such report accurately describes the methods and standard operating... LABORATORY PRACTICE STANDARDS Organization and Personnel § 160.35 Quality assurance unit. (a) A testing...
Self-testing for HIV: a new option for HIV prevention?
Spielberg, Freya; Levine, Ruth O; Weaver, Marcia
2004-10-01
Self-testing has the potential to be an innovative component to community-wide HIV-prevention strategies. This testing method could serve populations who do not have access to standard voluntary counselling and testing services or because of privacy concerns, stigma, transport costs, or other barriers do not use facility-based, standard HIV testing. This paper reviews recent research on the acceptability, feasibility, and cost of rapid testing and home-specimen collection for HIV, and suggests that self-testing may be another important strategy for diagnosing HIV infection. Several research questions are posed that should be answered before self-testing is realised.
Analytical methods for determining fire resistance of timber members
Robert H. White
2008-01-01
The fire resistance ratings of wood members and assemblies, as of other materials, have traditionally been obtained by testing the assembly in a furnace in accordance with ASTM International (ASTM) Standard E119, International Organization for Standardization (ISO) Standard 834, and similar standards. These ratings are published in listings, such as Underwriters...
The History of a Decision: A Standard Vibration Test Method for Qualification
Rizzo, Davinia; Blackburn, Mark
2017-01-01
As Mil-Std-810G and subsequent versions have included multiple degree of freedom vibration test methodologies, it is important to understand the history and factors that drove the original decision in Mil-Std-810 to focus on single degree of freedom (SDOF) vibration testing. By assessing the factors and thought process of early Mil-Std-810 vibration test methods, it enables one to better consider the use of multiple degree of freedom testing now that it is feasible with today’s technology and documented in Mil-Std-810. This paper delves into the details of the decision made in the 1960s for the SDOF vibration testing standards in Mil-Std-810more » beyond the limitations of technology at the time. We also consider the implications for effective test planning today considering the advances in test capabilities and improvements in understanding of the operational environment.« less
The History of a Decision: A Standard Vibration Test Method for Qualification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rizzo, Davinia; Blackburn, Mark
As Mil-Std-810G and subsequent versions have included multiple degree of freedom vibration test methodologies, it is important to understand the history and factors that drove the original decision in Mil-Std-810 to focus on single degree of freedom (SDOF) vibration testing. By assessing the factors and thought process of early Mil-Std-810 vibration test methods, it enables one to better consider the use of multiple degree of freedom testing now that it is feasible with today’s technology and documented in Mil-Std-810. This paper delves into the details of the decision made in the 1960s for the SDOF vibration testing standards in Mil-Std-810more » beyond the limitations of technology at the time. We also consider the implications for effective test planning today considering the advances in test capabilities and improvements in understanding of the operational environment.« less
Comparison of a New and Rapid Method: Brucella Coombs Gel Test With Other Diagnostic Tests.
Kalem, Fatma; Ergün, Ayşe Gül; Durmaz, Süleyman; Doğan, Metin; Ertuğrul, Ömür; Gündem, Seval
2016-09-01
The aim of this study was to detect reliability of Brucella Coombs gel test (BCGT) by comparing with with ELISA (IgG + IgM), Standard agglutination test, and Brucella immunocapture agglutination methods in serological diagnosis of brucellosis. Brucella Coombs gel test (BCGT), Brucella ELISA (IgG + IgM), Standard agglutination test, and Brucella immunocapture agglutination tests of 78 patients with presumptive diagnosis of brucellosis which were sent to Microbiology Laboratory of Konya Numune Hospital from various regions of Konya were studied. Of 78 patients with ELISA IgG and IgM, STA, BICA and BCGT; 26, 21, 10, 12 and 12 were positive. When compared with BICA, the sensitivity and specifity of BCGT were 100% and 100%, respectively. According to results BCGT can be used as a diagnostic test in routine laboratories after more comprehensive studies in control groups and patients. © 2016 Wiley Periodicals, Inc.
[Testing methods for the characterization of catheter balloons and lumina].
Werner, C; Rössler, K; Deckert, F
1995-10-01
The present paper reports on the characterization of catheter balloons and lumina on the basis of such known parameters as residual volume, compliance, burst pressure and flow rate, with the aim of developing standards, test methods and testing equipment as well as standards. These are becoming ever more important with the coming into force of the EC directive on medical products [7] and the law governing medical products in Germany [13], which requires manufacturers to specify the properties of their products. Our testing concept is based on a commercially available machine that subjects materials to alternating extension and compression forces over the long-term, to which we added a special hydraulic module. Using the multimedia technology we achieved a real time superimposition of the volume-diameter curve on the balloon. The function of the testing device and method is demonstrated on dilatation catheters. Our initial results reveal compatibility with the requirements of the 1% accuracy class. Use of this methodology for comparative testing of catheters and quality evaluation is recommended.
Sixty-five years since the New York heat wave: advances in sweat testing for cystic fibrosis.
Collie, Jake T B; Massie, R John; Jones, Oliver A H; LeGrys, Vicky A; Greaves, Ronda F
2014-02-01
The sweat test remains important as a diagnostic test for cystic fibrosis (CF) and has contributed greatly to our understanding of CF as a disease of epithelial electrolyte transport. The standardization of the sweat test, by Gibson and Cooke [Gibson and Cooke (1959) Pediatrics 1959;23:5], followed observations of excessive dehydration amongst patients with CF and confirmed the utility as a diagnostic test. Quantitative pilocarpine iontophoresis remains the gold standard for sweat induction, but there are a number of collection and analytical methods. The pathophysiology of electrolyte transport in sweat was described by Quinton [Quinton (1983) Nature 1983;301:421-422], and this complemented the developments in genetics that discovered the cystic fibrosis transmembrane conductance regulator (CFTR), an epithelial-based electrolyte transport protein. Knowledge of CF has since increased rapidly and further developments in sweat testing include: new collection methods, further standardization of the technique with international recommendations and age related reference intervals. More recently, sweat chloride values have been used as proof of effect for the new drugs that activate CFTR. However, there remain issues with adherence to sweat test guidelines in many countries and there are gaps in our knowledge, including reference intervals for some age groups and stability of sweat samples in transport. Furthermore, modern methods of elemental quantification need to be explored as alternatives to the original analytical methods for sweat electrolyte measurement. The purpose of this review is therefore to describe the development of the sweat test and consider future directions. © 2013 Wiley Periodicals, Inc.
A unified in vitro evaluation for apatite-forming ability of bioactive glasses and their variants.
Maçon, Anthony L B; Kim, Taek B; Valliant, Esther M; Goetschius, Kathryn; Brow, Richard K; Day, Delbert E; Hoppe, Alexander; Boccaccini, Aldo R; Kim, Ill Yong; Ohtsuki, Chikara; Kokubo, Tadashi; Osaka, Akiyoshi; Vallet-Regí, Maria; Arcos, Daniel; Fraile, Leandro; Salinas, Antonio J; Teixeira, Alexandra V; Vueva, Yuliya; Almeida, Rui M; Miola, Marta; Vitale-Brovarone, Chiara; Verné, Enrica; Höland, Wolfram; Jones, Julian R
2015-02-01
The aim of this study was to propose and validate a new unified method for testing dissolution rates of bioactive glasses and their variants, and the formation of calcium phosphate layer formation on their surface, which is an indicator of bioactivity. At present, comparison in the literature is difficult as many groups use different testing protocols. An ISO standard covers the use of simulated body fluid on standard shape materials but it does not take into account that bioactive glasses can have very different specific surface areas, as for glass powders. Validation of the proposed modified test was through round robin testing and comparison to the ISO standard where appropriate. The proposed test uses fixed mass per solution volume ratio and agitated solution. The round robin study showed differences in hydroxyapatite nucleation on glasses of different composition and between glasses of the same composition but different particle size. The results were reproducible between research facilities. Researchers should use this method when testing new glasses, or their variants, to enable comparison between the literature in the future.
Detecting Gear Tooth Fatigue Cracks in Advance of Complete Fracture
NASA Technical Reports Server (NTRS)
Zakrajsek, James J.; Lewicki, David G.
1996-01-01
Results of using vibration-based methods to detect gear tooth fatigue cracks are presented. An experimental test rig was used to fail a number of spur gear specimens through bending fatigue. The gear tooth fatigue crack in each test was initiated through a small notch in the fillet area of a tooth on the gear. The primary purpose of these tests was to verify analytical predictions of fatigue crack propagation direction and rate as a function of gear rim thickness. The vibration signal from a total of three tests was monitored and recorded for gear fault detection research. The damage consisted of complete rim fracture on the two thin rim gears and single tooth fracture on the standard full rim test gear. Vibration-based fault detection methods were applied to the vibration signal both on-line and after the tests were completed. The objectives of this effort were to identify methods capable of detecting the fatigue crack and to determine how far in advance of total failure positive detection was given. Results show that the fault detection methods failed to respond to the fatigue crack prior to complete rim fracture in the thin rim gear tests. In the standard full rim gear test all of the methods responded to the fatigue crack in advance of tooth fracture; however, only three of the methods responded to the fatigue crack in the early stages of crack propagation.
Use of the Digital Surface Roughness Meter in Virginia.
DOT National Transportation Integrated Search
2006-01-01
Pavement surface texture is measured in a variety of ways in Virginia. Two methods commonly used are ASTM E 965, Standard Test Method for Measuring Pavement Macrotexture Depth Using a Volumetric Technique, known as the "sand patch" test, and ASTM E 2...
7 CFR 58.930 - Official test methods.
Code of Federal Regulations, 2010 CFR
2010-01-01
..., GENERAL SPECIFICATIONS FOR APPROVED PLANTS AND STANDARDS FOR GRADES OF DAIRY PRODUCTS 1 General Specifications for Dairy Plants Approved for USDA Inspection and Grading Service 1 Operations and Operating Procedures § 58.930 Official test methods. (a) Chemical. Chemical analysis, except where otherwise prescribed...
7 CFR 58.930 - Official test methods.
Code of Federal Regulations, 2012 CFR
2012-01-01
..., GENERAL SPECIFICATIONS FOR APPROVED PLANTS AND STANDARDS FOR GRADES OF DAIRY PRODUCTS 1 General Specifications for Dairy Plants Approved for USDA Inspection and Grading Service 1 Operations and Operating Procedures § 58.930 Official test methods. (a) Chemical. Chemical analysis, except where otherwise prescribed...
7 CFR 58.930 - Official test methods.
Code of Federal Regulations, 2013 CFR
2013-01-01
..., GENERAL SPECIFICATIONS FOR APPROVED PLANTS AND STANDARDS FOR GRADES OF DAIRY PRODUCTS 1 General Specifications for Dairy Plants Approved for USDA Inspection and Grading Service 1 Operations and Operating Procedures § 58.930 Official test methods. (a) Chemical. Chemical analysis, except where otherwise prescribed...
7 CFR 58.930 - Official test methods.
Code of Federal Regulations, 2011 CFR
2011-01-01
..., GENERAL SPECIFICATIONS FOR APPROVED PLANTS AND STANDARDS FOR GRADES OF DAIRY PRODUCTS 1 General Specifications for Dairy Plants Approved for USDA Inspection and Grading Service 1 Operations and Operating Procedures § 58.930 Official test methods. (a) Chemical. Chemical analysis, except where otherwise prescribed...
7 CFR 58.930 - Official test methods.
Code of Federal Regulations, 2014 CFR
2014-01-01
..., GENERAL SPECIFICATIONS FOR APPROVED PLANTS AND STANDARDS FOR GRADES OF DAIRY PRODUCTS 1 General Specifications for Dairy Plants Approved for USDA Inspection and Grading Service 1 Operations and Operating Procedures § 58.930 Official test methods. (a) Chemical. Chemical analysis, except where otherwise prescribed...
The relationship between onsite manufacture of spray polyurethane foam insulation (SPFI) and potential exposures is not well understood. Currently, no comprehensive standard test methods exist for characterizing and quantifying product emissions. Exposures to diisocyanate compoun...
Ozseven, Ayşe Gül; Sesli Çetin, Emel; Ozseven, Levent
2012-07-01
In recent years, owing to the presence of multi-drug resistant nosocomial bacteria, combination therapies are more frequently applied. Thus there is more need to investigate the in vitro activity of drug combinations against multi-drug resistant bacteria. Checkerboard synergy testing is among the most widely used standard technique to determine the activity of antibiotic combinations. It is based on microdilution susceptibility testing of antibiotic combinations. Although this test has a standardised procedure, there are many different methods for interpreting the results. In many previous studies carried out with multi-drug resistant bacteria, different rates of synergy have been reported with various antibiotic combinations using checkerboard technique. These differences might be attributed to the different features of the strains. However, different synergy rates detected by checkerboard method have also been reported in other studies using the same drug combinations and same types of bacteria. It was thought that these differences in synergy rates might be due to the different methods of interpretation of synergy test results. In recent years, multi-drug resistant Acinetobacter baumannii has been the most commonly encountered nosocomial pathogen especially in intensive-care units. For this reason, multidrug resistant A.baumannii has been the subject of a considerable amount of research about antimicrobial combinations. In the present study, the in vitro activities of frequently preferred combinations in A.baumannii infections like imipenem plus ampicillin/sulbactam, and meropenem plus ampicillin/sulbactam were tested by checkerboard synergy method against 34 multi-drug resistant A.baumannii isolates. Minimum inhibitory concentration (MIC) values for imipenem, meropenem and ampicillin/sulbactam were determined by the broth microdilution method. Subsequently the activity of two different combinations were tested in the dilution range of 4 x MIC and 0.03 x MIC in 96-well checkerboard plates. The results were obtained separately using the four different interpretation methods frequently preferred by researchers. Thus, it was aimed to detect to what extent the rates of synergistic, indifferent and antagonistic interactions were affected by different interpretation methods. The differences between the interpretation methods were tested by chi-square analysis for each combination used. Statistically significant differences were detected between the four different interpretation methods for the determination of synergistic and indifferent interactions (p< 0.0001). Highest rates of synergy were observed with both combinations by the method that used the lowest fractional inhibitory concentration index of all the non-turbid wells along the turbidity/non-turbidity interface. There was no statistically significant difference between the four methods for the detection of antagonism (p> 0.05). In conclusion although there is a standard procedure for checkerboard synergy testing it fails to exhibit standard results owing to different methods of interpretation of the results. Thus, there is a need to standardise the interpretation method for checkerboard synergy testing. To determine the most appropriate method of interpretation further studies investigating the clinical benefits of synergic combinations and additionally comparing the consistency of the results obtained from the other standard combination tests like time-kill studies, are required.
NASA Technical Reports Server (NTRS)
Buehler, Martin G. (Inventor); Nixon, Robert H. (Inventor); Soli, George A. (Inventor); Blaes, Brent R. (Inventor)
1995-01-01
A method for predicting the SEU susceptibility of a standard-cell D-latch using an alpha-particle sensitive SRAM, SPICE critical charge simulation results, and alpha-particle interaction physics. A technique utilizing test structures to quickly and inexpensively characterize the SEU sensitivity of standard cell latches intended for use in a space environment. This bench-level approach utilizes alpha particles to induce upsets in a low LET sensitive 4-k bit test SRAM. This SRAM consists of cells that employ an offset voltage to adjust their upset sensitivity and an enlarged sensitive drain junction to enhance the cell's upset rate.
Gravimetric screening method for fungal decay of paper: inoculation with Trametes versicolor.
Råberg, Ulrika; Hafrén, Jonas
2009-10-01
The European standard test EN 113 for fungal degradation of solid wood has been adapted for degradation of paper by white rot fungus (Trametes versicolor). Fungal degradation of paper sheets may potentially be used for screening different wood preservatives on paper instead of solid wood. The paper samples showed higher relative mass losses compared to wood, and samples pretreated with boric acid, copper sulfate and polymerized linseed oil were successfully tested for biodegradation using the paper sheet method. The results on paper degradation were compared with wood, both as wood blocks (according to standard test) and wood cut in sections forming layered structures mimicking paper layers.
Yousuf, R; Abdul Ghani, S A; Abdul Khalid, N; Leong, C F
2018-04-01
'InTec Blood Grouping Test kit' using solid-phase technology is a new method which may be used at outdoor blood donation site or at bed side as an alternative to the conventional tile method in view of its stability at room temperature and fulfilled the criteria as point of care test. This study aimed to compare the efficiency of this solid phase method (InTec Blood Grouping Test Kit) with the conventional tile method in determining the ABO and RhD blood group of healthy donors. A total of 760 voluntary donors who attended the Blood Bank, Penang Hospital or offsite blood donation campaigns from April to May 2014 were recruited. The ABO and RhD blood groups were determined by the conventional tile method and the solid phase method, in which the tube method was used as the gold standard. For ABO blood grouping, the tile method has shown 100% concordance results with the gold standard tube method, whereas the solid-phase method only showed concordance result for 754/760 samples (99.2%). Therefore, for ABO grouping, tile method has 100% sensitivity and specificity while the solid phase method has slightly lower sensitivity of 97.7% but both with good specificity of 100%. For RhD grouping, both the tile and solid phase methods have grouped one RhD positive specimen as negative each, thus giving the sensitivity and specificity of 99.9% and 100% for both methods respectively. The 'InTec Blood Grouping Test Kit' is suitable for offsite usage because of its simplicity and user friendliness. However, further improvement in adding the internal quality control may increase the test sensitivity and validity of the test results.
46 CFR 164.015-1 - Applicable specifications and standards.
Code of Federal Regulations, 2010 CFR
2010-10-01
..., CONSTRUCTION, AND MATERIALS: SPECIFICATIONS AND APPROVAL MATERIALS Plastic Foam, Unicellular, Buoyant, Sheet... following specification and standard, of the issue in effect on the date the plastic foam material is...) ASTM D4986-98, Standard Test Method for Horizontal Burning Characteristics of Cellular Polymeric...
Improved ASTM G72 Test Method for Ensuring Adequate Fuel-to-Oxidizer Ratios
NASA Technical Reports Server (NTRS)
Juarez, Alfredo; Harper, Susana A.
2016-01-01
The ASTM G72/G72M-15 Standard Test Method for Autogenous Ignition Temperature of Liquids and Solids in a High-Pressure Oxygen-Enriched Environment is currently used to evaluate materials for the ignition susceptibility driven by exposure to external heat in an enriched oxygen environment. Testing performed on highly volatile liquids such as cleaning solvents has proven problematic due to inconsistent test results (non-ignitions). Non-ignition results can be misinterpreted as favorable oxygen compatibility, although they are more likely associated with inadequate fuel-to-oxidizer ratios. Forced evaporation during purging and inadequate sample size were identified as two potential causes for inadequate available sample material during testing. In an effort to maintain adequate fuel-to-oxidizer ratios within the reaction vessel during test, several parameters were considered, including sample size, pretest sample chilling, pretest purging, and test pressure. Tests on a variety of solvents exhibiting a range of volatilities are presented in this paper. A proposed improvement to the standard test protocol as a result of this evaluation is also presented. Execution of the final proposed improved test protocol outlines an incremental step method of determining optimal conditions using increased sample sizes while considering test system safety limits. The proposed improved test method increases confidence in results obtained by utilizing the ASTM G72 autogenous ignition temperature test method and can aid in the oxygen compatibility assessment of highly volatile liquids and other conditions that may lead to false non-ignition results.
Demonstrating Hemostasis with a Student-Designed Prothrombin Time Test
ERIC Educational Resources Information Center
Fardy, Richard Wiley
1978-01-01
Describes a blood coagulation test developed by two high school biology students. Although the test lacks some precision, results indicate that the technique is comparable to standard methods used in laboratories. (MA)
NASA Technical Reports Server (NTRS)
Salem, Jonathan A.; Jenkins, Michael G.
2003-01-01
Advanced aerospace systems occasionally require the use of very brittle materials such as sapphire and ultra-high temperature ceramics. Although great progress has been made in the development of methods and standards for machining, testing and design of component from these materials, additional development and dissemination of standard practices is needed. ASTM Committee C28 on Advanced Ceramics and ISO TC 206 have taken a lead role in the standardization of testing for ceramics, and recent efforts and needs in standards development by Committee C28 on Advanced Ceramics will be summarized. In some cases, the engineers, etc. involved are unaware of the latest developments, and traditional approaches applicable to other material systems are applied. Two examples of flight hardware failures that might have been prevented via education and standardization will be presented.
Hira-Kazal, R; Shea-Simonds, P; Peacock, J L; Maher, J
2015-01-01
Anti-nuclear antibody (ANA) testing assists in the diagnosis of several immune-mediated disorders. The gold standard method for detection of these antibodies is by indirect immunofluorescence testing on human epidermoid laryngeal carcinoma (HEp-2) cells. However, many laboratories test for these antibodies using solid-phase assays such as enzyme-linked immunosorbent assay (ELISA), which allows for higher throughput testing at reduced cost. In this study, we have audited the performance of a previously established ELISA assay to screen for ANA, making comparison with the gold standard HEp-2 immunofluorescence test. A prospective and unselected sample of 89 consecutive ANA test requests by consultant rheumatologists were evaluated in parallel over a period of 10 months using both tests. ELISA and HEp-2 screening assays yielded 40 (45%) and 72 (81%) positive test results, respectively, demonstrating lack of concordance between test methods. Using standard and clinical samples, it was demonstrated that the ELISA method did not detect several ANA with nucleolar, homogeneous and speckled immunofluorescence patterns. None of these ELISANEG HEp-2POS ANA were reactive with a panel of six extractable nuclear antigens or with double-stranded DNA. Nonetheless, 13 of these samples (15%) originated from patients with recognized ANA-associated disease (n = 7) or Raynaud's phenomenon (n = 6). We conclude that ELISA screening may fail to detect clinically relevant ANA that lack defined specificity for antigen. PMID:25412573
EMC Test Challenges for NASAs James Webb Space Telescope
NASA Technical Reports Server (NTRS)
McCloskey, John
2016-01-01
This presentation describes the electromagnetic compatibility (EMC) tests performed on the Integrated Science Instrument Module (ISIM), the science payload of the James Webb Space Telescope (JWST), at NASAs Goddard Space Flight Center (GSFC) in August 2015. By its very nature of being an integrated payload, it could be treated as neither a unit level test nor an integrated spacecraft observatory test. Non-standard test criteria are described along with non-standard test methods that had to be developed in order to evaluate them. Results are presented to demonstrate that all test criteria were met in less than the time allocated.
EMC Test Challenges for NASA's James Webb Space Telescope
NASA Technical Reports Server (NTRS)
McCloskey, John
2016-01-01
This presentation describes the electromagnetic compatibility (EMC) tests performed on the Integrated Science Instrument Module (ISIM), the science payload of the James Webb Space Telescope (JWST), at NASAs Goddard Space Flight Center (GSFC) in August 2015. By its very nature of being an integrated payload, it could be treated as neither a unit level test nor an integrated spacecraft observatory test. Non-standard test criteria are described along with non-standard test methods that had to be developed in order to evaluate them. Results are presented to demonstrate that all test criteria were met in less than the time allocated.
A Generally Robust Approach for Testing Hypotheses and Setting Confidence Intervals for Effect Sizes
ERIC Educational Resources Information Center
Keselman, H. J.; Algina, James; Lix, Lisa M.; Wilcox, Rand R.; Deering, Kathleen N.
2008-01-01
Standard least squares analysis of variance methods suffer from poor power under arbitrarily small departures from normality and fail to control the probability of a Type I error when standard assumptions are violated. This article describes a framework for robust estimation and testing that uses trimmed means with an approximate degrees of…
46 CFR 160.060-7 - Inspections and tests-standard and nonstandard vests. 1
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 6 2010-10-01 2010-10-01 false Inspections and tests-standard and nonstandard vests. 1... and nonstandard vests. 1 1 The manufacturer of a personal flotation device must meet 33 CFR 181.701... shall— (1) Maintain quality control of the materials used, the manufacturing methods, and the finished...
46 CFR 160.060-7 - Inspections and tests-standard and nonstandard vests. 1
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 6 2011-10-01 2011-10-01 false Inspections and tests-standard and nonstandard vests. 1... and nonstandard vests. 1 1 The manufacturer of a personal flotation device must meet 33 CFR 181.701... shall— (1) Maintain quality control of the materials used, the manufacturing methods, and the finished...
40 CFR 75.6 - Incorporation by reference.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., phone: 610-832-9585, http://www.astm.org/DIGITAL_LIBRARY/index.shtml. (1) ASTM D129-00, Standard Test... Information Reference Unit of the U.S. EPA, 401 M St., SW., Washington, DC and at the Library (MD-35), U.S... D4052-96 (Reapproved 2002), Standard Test Method for Density and Relative Density of Liquids by Digital...
40 CFR 75.6 - Incorporation by reference.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., phone: 610-832-9585, http://www.astm.org/DIGITAL_LIBRARY/index.shtml. (1) ASTM D129-00, Standard Test... Information Reference Unit of the U.S. EPA, 401 M St., SW., Washington, DC and at the Library (MD-35), U.S... D4052-96 (Reapproved 2002), Standard Test Method for Density and Relative Density of Liquids by Digital...
40 CFR 75.6 - Incorporation by reference.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., phone: 610-832-9585, http://www.astm.org/DIGITAL_LIBRARY/index.shtml. (1) ASTM D129-00, Standard Test... Information Reference Unit of the U.S. EPA, 401 M St., SW., Washington, DC and at the Library (MD-35), U.S... D4052-96 (Reapproved 2002), Standard Test Method for Density and Relative Density of Liquids by Digital...
40 CFR 75.6 - Incorporation by reference.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., phone: 610-832-9585, http://www.astm.org/DIGITAL_LIBRARY/index.shtml. (1) ASTM D129-00, Standard Test... Information Reference Unit of the U.S. EPA, 401 M St., SW., Washington, DC and at the Library (MD-35), U.S... D4052-96 (Reapproved 2002), Standard Test Method for Density and Relative Density of Liquids by Digital...
Concrete testing device provides substantial savings : fact sheet.
DOT National Transportation Integrated Search
2011-11-01
Current practices require a permeability test, ASTM C1202: "Standard Test Method for Electrical Indication of Concrete's Ability to resist Chloride Ion Penetration," for structures with potential salt water intrusion. The test is run at 56 days of ag...
Garcia Hejl, Carine; Ramirez, Jose Manuel; Vest, Philippe; Chianea, Denis; Renard, Christophe
2014-09-01
Laboratories working towards accreditation by the International Standards Organization (ISO) 15189 standard are required to demonstrate the validity of their analytical methods. The different guidelines set by various accreditation organizations make it difficult to provide objective evidence that an in-house method is fit for the intended purpose. Besides, the required performance characteristics tests and acceptance criteria are not always detailed. The laboratory must choose the most suitable validation protocol and set the acceptance criteria. Therefore, we propose a validation protocol to evaluate the performance of an in-house method. As an example, we validated the process for the detection and quantification of lead in whole blood by electrothermal absorption spectrometry. The fundamental parameters tested were, selectivity, calibration model, precision, accuracy (and uncertainty of measurement), contamination, stability of the sample, reference interval, and analytical interference. We have developed a protocol that has been applied successfully to quantify lead in whole blood by electrothermal atomic absorption spectrometry (ETAAS). In particular, our method is selective, linear, accurate, and precise, making it suitable for use in routine diagnostics.
Standardization of shape memory alloy test methods toward certification of aerospace applications
NASA Astrophysics Data System (ADS)
Hartl, D. J.; Mabe, J. H.; Benafan, O.; Coda, A.; Conduit, B.; Padan, R.; Van Doren, B.
2015-08-01
The response of shape memory alloy (SMA) components employed as actuators has enabled a number of adaptable aero-structural solutions. However, there are currently no industry or government-accepted standardized test methods for SMA materials when used as actuators and their transition to commercialization and production has been hindered. This brief fast track communication introduces to the community a recently initiated collaborative and pre-competitive SMA specification and standardization effort that is expected to deliver the first ever regulatory agency-accepted material specification and test standards for SMA as employed as actuators for commercial and military aviation applications. In the first phase of this effort, described herein, the team is working to review past efforts and deliver a set of agreed-upon properties to be included in future material certification specifications as well as the associated experiments needed to obtain them in a consistent manner. Essential for the success of this project is the participation and input from a number of organizations and individuals, including engineers and designers working in materials and processing development, application design, SMA component fabrication, and testing at the material, component, and system level. Going forward, strong consensus among this diverse body of participants and the SMA research community at large is needed to advance standardization concepts for universal adoption by the greater aerospace community and especially regulatory bodies. It is expected that the development and release of public standards will be done in collaboration with an established standards development organization.
Comparison of attrition test methods: ASTM standard fluidized bed vs jet cup
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhao, R.; Goodwin, J.G. Jr.; Jothimurugesan, K.
2000-05-01
Attrition resistance is one of the key design parameters for catalysts used in fluidized-bed and slurry phase types of reactors. The ASTM fluidized-bed test has been one of the most commonly used attrition resistance evaluation methods; however, it requires the use of 50 g samples--a large amount for catalyst development studies. Recently a test using the jet cup requiring only 5 g samples has been proposed. In the present study, two series of spray-dried iron catalysts were evaluated using both the ASTM fluidized-bed test and a test based on the jet cup to determine this comparability. It is shown thatmore » the two tests give comparable results. This paper, by reporting a comparison of the jet-cup test with the ASTM standard, provides a basis for utilizing the more efficient jet cup with confidence in catalyst attrition studies.« less
Validity evidence based on test content.
Sireci, Stephen; Faulkner-Bond, Molly
2014-01-01
Validity evidence based on test content is one of the five forms of validity evidence stipulated in the Standards for Educational and Psychological Testing developed by the American Educational Research Association, American Psychological Association, and National Council on Measurement in Education. In this paper, we describe the logic and theory underlying such evidence and describe traditional and modern methods for gathering and analyzing content validity data. A comprehensive review of the literature and of the aforementioned Standards is presented. For educational tests and other assessments targeting knowledge and skill possessed by examinees, validity evidence based on test content is necessary for building a validity argument to support the use of a test for a particular purpose. By following the methods described in this article, practitioners have a wide arsenal of tools available for determining how well the content of an assessment is congruent with and appropriate for the specific testing purposes.
Zietze, Stefan; Müller, Rainer H; Brecht, René
2008-03-01
In order to set up a batch-to-batch-consistency analytical scheme for N-glycosylation analysis, several sample preparation steps including enzyme digestions and fluorophore labelling and two HPLC-methods were established. The whole method scheme was standardized, evaluated and validated according to the requirements on analytical testing in early clinical drug development by usage of a recombinant produced reference glycoprotein (RGP). The standardization of the methods was performed by clearly defined standard operation procedures. During evaluation of the methods, the major interest was in the loss determination of oligosaccharides within the analytical scheme. Validation of the methods was performed with respect to specificity, linearity, repeatability, LOD and LOQ. Due to the fact that reference N-glycan standards were not available, a statistical approach was chosen to derive accuracy from the linearity data. After finishing the validation procedure, defined limits for method variability could be calculated and differences observed in consistency analysis could be separated into significant and incidental ones.
Harmonisation of microbial sampling and testing methods for distillate fuels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hill, G.C.; Hill, E.C.
1995-05-01
Increased incidence of microbial infection in distillate fuels has led to a demand for organisations such as the Institute of Petroleum to propose standards for microbiological quality, based on numbers of viable microbial colony forming units. Variations in quality requirements, and in the spoilage significance of contaminating microbes plus a tendency for temporal and spatial changes in the distribution of microbes, makes such standards difficult to implement. The problem is compounded by a diversity in the procedures employed for sampling and testing for microbial contamination and in the interpretation of the data obtained. The following paper reviews these problems andmore » describes the efforts of The Institute of Petroleum Microbiology Fuels Group to address these issues and in particular to bring about harmonisation of sampling and testing methods. The benefits and drawbacks of available test methods, both laboratory based and on-site, are discussed.« less
Measures of fish behavior as indicators of sublethal toxicosis during standard toxicity tests
Little, E.E.; DeLonay, A.J.
1996-01-01
Behavioral functions essential for growth and survival can be dramatically altered by sublethal exposure to toxicants. Measures of these behavioral responses are effective in detecting adverse effects of sublethal contaminant exposure. Behavioral responses of fishes can be qualitatively and quantitatively evaluated during routine toxicity tests. At selected intervals of exposure, qualitative evaluations are accomplished through direct observations, whereas video recordings are used for quantitative evaluations. Standardized procedures for behavioral evaluation are readily applicable to different fish species and provide rapid, sensitive, and ecologically relevant assessments of sublethal exposure. The methods are readily applied to standardized test protocols.
Moore, Tyler M.; Reise, Steven P.; Roalf, David R.; Satterthwaite, Theodore D.; Davatzikos, Christos; Bilker, Warren B.; Port, Allison M.; Jackson, Chad T.; Ruparel, Kosha; Savitt, Adam P.; Baron, Robert B.; Gur, Raquel E.; Gur, Ruben C.
2016-01-01
Traditional “paper-and-pencil” testing is imprecise in measuring speed and hence limited in assessing performance efficiency, but computerized testing permits precision in measuring itemwise response time. We present a method of scoring performance efficiency (combining information from accuracy and speed) at the item level. Using a community sample of 9,498 youths age 8-21, we calculated item-level efficiency scores on four neurocognitive tests, and compared the concurrent, convergent, discriminant, and predictive validity of these scores to simple averaging of standardized speed and accuracy-summed scores. Concurrent validity was measured by the scores' abilities to distinguish men from women and their correlations with age; convergent and discriminant validity were measured by correlations with other scores inside and outside of their neurocognitive domains; predictive validity was measured by correlations with brain volume in regions associated with the specific neurocognitive abilities. Results provide support for the ability of itemwise efficiency scoring to detect signals as strong as those detected by standard efficiency scoring methods. We find no evidence of superior validity of the itemwise scores over traditional scores, but point out several advantages of the former. The itemwise efficiency scoring method shows promise as an alternative to standard efficiency scoring methods, with overall moderate support from tests of four different types of validity. This method allows the use of existing item analysis methods and provides the convenient ability to adjust the overall emphasis of accuracy versus speed in the efficiency score, thus adjusting the scoring to the real-world demands the test is aiming to fulfill. PMID:26866796