Sample records for test method tm

  1. An Evaluation of Kernel Equating: Parallel Equating with Classical Methods in the SAT Subject Tests[TM] Program. Research Report. ETS RR-09-06

    ERIC Educational Resources Information Center

    Grant, Mary C.; Zhang, Lilly; Damiano, Michele

    2009-01-01

    This study investigated kernel equating methods by comparing these methods to operational equatings for two tests in the SAT Subject Tests[TM] program. GENASYS (ETS, 2007) was used for all equating methods and scaled score kernel equating results were compared to Tucker, Levine observed score, chained linear, and chained equipercentile equating…

  2. Comparative rice seed toxicity tests using filter paper, growth pouch-tm, and seed tray methods

    USGS Publications Warehouse

    Wang, W.

    1993-01-01

    Paper substrate, especially circular filter paper placed inside a Petri dish, has long been used for the plant seed toxicity test (PSTT). Although this method is simple and inexpensive, recent evidence indicates that it gives results that are significantly different from those obtained using a method that does not involve paper, especially when testing metal cations. The study compared PSTT using three methods: filter paper, Growth Pouch-TM, and seed tray. The Growth Pouch-TM is a commercially available device. The seed tray is a newly designed plastic receptacle placed inside a Petri dish. The results of the Growth Pouch-TM method showed no toxic effects on rice for Ag up to 40 mg L-1 and Cd up to 20 mg L-1. Using the seed tray method, IC50 (50% inhibitory effect concentration) values were 0.55 and 1.4 mg L-1 for Ag and Cd, respectively. Although results of filter paper and seed tray methods were nearly identical for NaF, Cr(VI), and phenol, the toxicities of cations Ag and Cd were reduced by using the filter paper method; IC50 values were 22 and 18 mg L-1, respectively. The results clearly indicate that paper substrate is not advisable for PSTT.

  3. A novel method of measuring the melting point of animal fats.

    PubMed

    Lloyd, S S; Dawkins, S T; Dawkins, R L

    2014-10-01

    The melting point (TM) of fat is relevant to health, but available methods of determining TM are cumbersome. One of the standard methods of measuring TM for animal and vegetable fats is the slip point, also known as the open capillary method. This method is imprecise and not amenable to automation or mass testing. We have developed a technique for measuring TM of animal fat using the Rotor-Gene Q (Qiagen, Hilden, Germany). The assay has an intra-assay SD of 0.08°C. A single operator can extract and assay up to 250 samples of animal fat in 24 h, including the time to extract the fat from the adipose tissue. This technique will improve the quality of research into genetic and environmental contributions to fat composition of meat.

  4. Evaluation of penicillin G residues by kidney inhibition swab tests in sow body fluids and tissues following intramuscular injection

    USDA-ARS?s Scientific Manuscript database

    In 2011, the USDA-Food Safety and Inspection Service (FSIS) changed the method used for screening swine tissues for antimicrobial residues from the Fast Antimicrobial Screen Test to the Kidney Inhibition Swab (KIS(TM)). Here, we describe the use of KIS(TM) test for the detection of penicillin G res...

  5. Trabecular meshwork stiffness in glaucoma.

    PubMed

    Wang, Ke; Read, A Thomas; Sulchek, Todd; Ethier, C Ross

    2017-05-01

    Alterations in stiffness of the trabecular meshwork (TM) may play an important role in primary open-angle glaucoma (POAG), the second leading cause of blindness. Specifically, certain data suggest an association between elevated intraocular pressure (IOP) and increased TM stiffness; however, the underlying link between TM stiffness and IOP remains unclear and requires further study. We here first review the literature on TM stiffness measurements, encompassing various species and based on a number of measurement techniques, including direct approaches such as atomic force microscopy (AFM) and uniaxial tension tests, and indirect methods based on a beam deflection model. We also briefly review the effects of several factors that affect TM stiffness, including lysophospholipids, rho-kinase inhibitors, cytoskeletal disrupting agents, dexamethasone (DEX), transforming growth factor-β 2 (TGF-β 2 ), nitric oxide (NO) and cellular senescence. We then describe a method we have developed for determining TM stiffness measurement in mice using a cryosection/AFM-based approach, and present preliminary data on TM stiffness in C57BL/6J and CBA/J mouse strains. Finally, we investigate the relationship between TM stiffness and outflow facility between these two strains. The method we have developed shows promise for further direct measurements of mouse TM stiffness, which may be of value in understanding mechanistic relations between outflow facility and TM biomechanical properties. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. COMSAT: Residue contact prediction of transmembrane proteins based on support vector machines and mixed integer linear programming.

    PubMed

    Zhang, Huiling; Huang, Qingsheng; Bei, Zhendong; Wei, Yanjie; Floudas, Christodoulos A

    2016-03-01

    In this article, we present COMSAT, a hybrid framework for residue contact prediction of transmembrane (TM) proteins, integrating a support vector machine (SVM) method and a mixed integer linear programming (MILP) method. COMSAT consists of two modules: COMSAT_SVM which is trained mainly on position-specific scoring matrix features, and COMSAT_MILP which is an ab initio method based on optimization models. Contacts predicted by the SVM model are ranked by SVM confidence scores, and a threshold is trained to improve the reliability of the predicted contacts. For TM proteins with no contacts above the threshold, COMSAT_MILP is used. The proposed hybrid contact prediction scheme was tested on two independent TM protein sets based on the contact definition of 14 Å between Cα-Cα atoms. First, using a rigorous leave-one-protein-out cross validation on the training set of 90 TM proteins, an accuracy of 66.8%, a coverage of 12.3%, a specificity of 99.3% and a Matthews' correlation coefficient (MCC) of 0.184 were obtained for residue pairs that are at least six amino acids apart. Second, when tested on a test set of 87 TM proteins, the proposed method showed a prediction accuracy of 64.5%, a coverage of 5.3%, a specificity of 99.4% and a MCC of 0.106. COMSAT shows satisfactory results when compared with 12 other state-of-the-art predictors, and is more robust in terms of prediction accuracy as the length and complexity of TM protein increase. COMSAT is freely accessible at http://hpcc.siat.ac.cn/COMSAT/. © 2016 Wiley Periodicals, Inc.

  7. Evaluation of Existing Methods for Human Blood mRNA Isolation and Analysis for Large Studies

    PubMed Central

    Meyer, Anke; Paroni, Federico; Günther, Kathrin; Dharmadhikari, Gitanjali; Ahrens, Wolfgang; Kelm, Sørge; Maedler, Kathrin

    2016-01-01

    Aims Prior to implementing gene expression analyses from blood to a larger cohort study, an evaluation to set up a reliable and reproducible method is mandatory but challenging due to the specific characteristics of the samples as well as their collection methods. In this pilot study we optimized a combination of blood sampling and RNA isolation methods and present reproducible gene expression results from human blood samples. Methods The established PAXgeneTM blood collection method (Qiagen) was compared with the more recent TempusTM collection and storing system. RNA from blood samples collected by both systems was extracted on columns with the corresponding Norgen and PAX RNA extraction Kits. RNA quantity and quality was compared photometrically, with Ribogreen and by Real-Time PCR analyses of various reference genes (PPIA, β-ACTIN and TUBULIN) and exemplary of SIGLEC-7. Results Combining different sampling methods and extraction kits caused strong variations in gene expression. The use of PAXgeneTM and TempusTM collection systems resulted in RNA of good quality and quantity for the respective RNA isolation system. No large inter-donor variations could be detected for both systems. However, it was not possible to extract sufficient RNA of good quality with the PAXgeneTM RNA extraction system from samples collected by TempusTM collection tubes. Comparing only the Norgen RNA extraction methods, RNA from blood collected either by the TempusTM or PAXgeneTM collection system delivered sufficient amount and quality of RNA, but the TempusTM collection delivered higher RNA concentration compared to the PAXTM collection system. The established Pre-analytix PAXgeneTM RNA extraction system together with the PAXgeneTM blood collection system showed lowest CT-values, i.e. highest RNA concentration of good quality. Expression levels of all tested genes were stable and reproducible. Conclusions This study confirms that it is not possible to mix or change sampling or extraction strategies during the same study because of large variations of RNA yield and expression levels. PMID:27575051

  8. Evaluation of Petrifilms(TM) as a diagnostic test to detect bovine mastitis organisms in Kenya.

    PubMed

    Gitau, George K; Bundi, Royford M; Vanleeuwen, John; Mulei, Charles M

    2013-03-01

    The study purpose was to validate Petrifilms(TM) (3M Microbiology, 2005) against standard culture methods in the diagnosis of bovine mastitis organisms in Kenya. On 128 smallholder dairy cattle farms in Kenya, between June 21, 2010 and August 31, 2010, milk samples from 269 cows that were positive on California Mastitis Test (CMT) were cultured using standard laboratory culture methods and Petrifilms(TM) (Aerobic Count and Coliform Count -3M Microbiology, 2005), and results were compared. Staphylococcus aureus was the most common bacterium isolated (73 % of samples). Clinical mastitis was found in only three cows, and there were only two Gram-negative isolates, making it impossible to examine the agreement between the two tests for Gram-negative- or clinical mastitis samples. The observed agreement between the standard culture and Petrifilm(TM) (3M Microbiology, 2005) results for Gram-positive isolates was 85 %, and there was fair agreement beyond that expected due to chance alone, with a kappa (κ) of 0.38. Using culture results as a gold standard, the Petrifilms(TM) had a sensitivity of 90 % for Gram-positive samples and specificity of 51 %. With 87 % of CMT-positive samples resulting in Gram-positive pathogens cultured, there was a positive predictive value of 93 % and a negative predictive value of 43 %. Petrifilms(TM) should be considered for culture of mastitis organisms in developing countries, especially when Gram-positive bacteria are expected.

  9. Quick test for percent of deleterious material.

    DOT National Transportation Integrated Search

    2009-08-28

    The Missouri Department of Transportation (MoDOT) is considering the replacement of its deleterious : materials test method (TM-71) with test methods that are more objective. MoDOT contracted with the Missouri : University of Science and Technology (...

  10. In vitro analysis of shear bond strength and adhesive remnant index of different metal brackets

    PubMed Central

    Henkin, Fernanda de Souza; de Macêdo, Érika de Oliveira Dias; Santos, Karoline da Silva; Schwarzbach, Marília; Samuel, Susana Maria Werner; Mundstock, Karina Santos

    2016-01-01

    ABSTRACT Introduction: There is a great variety of orthodontic brackets in the Brazilian market, and constantly evaluating them is critical for professionals to know their properties, so as to be able to choose which product best suits their clinical practice. Objectives: To evaluate the bond strength and the adhesive remnant index (ARI) of different brands of metal brackets. Material and Methods: A total of 105 bovine incisors were used, and brackets of different brands were bonded to teeth. Seven different bracket brands were tested (MorelliTM, American OrthodonticsTM, TP OrthodonticsTM, Abzil-3MTM, OrthometricTM, TecnidentTM and UNIDENTM). Twenty-four hours after bonding, shear bond strength test was performed; and after debonding, the ARI was determined by using an optical microscope at a 10-fold increase. Results: Mean shear bond strength values ranged from 3.845 ± 3.997 (MorelliTM) to 9.871 ± 5.106 MPa (TecnidentTM). The majority of the ARI index scores was 0 and 1. Conclusion: Among the evaluated brackets, the one with the lowest mean shear bond strength values was MorelliTM. General evaluation of groups indicated that a greater number of bond failure occurred at the enamel/adhesive interface. PMID:28125142

  11. Field comparison of OraQuick® ADVANCE Rapid HIV-1/2 antibody test and two blood-based rapid HIV antibody tests in Zambia

    PubMed Central

    2012-01-01

    Background Zambia’s national HIV testing algorithm specifies use of two rapid blood based antibody assays, Determine®HIV-1/2 (Inverness Medical) and if positive then Uni-GoldTM Recombigen HIV-1/2 (Trinity Biotech). Little is known about the performance of oral fluid based HIV testing in Zambia. The aims of this study are two-fold: 1) to compare the diagnostic accuracy (sensitivity and specificity) under field conditions of the OraQuick® ADVANCE® Rapid HIV-1/2 (OraSure Technologies, Inc.) to two blood-based rapid antibody tests currently in use in the Zambia National Algorithm, and 2) to perform a cost analysis of large-scale field testing employing the OraQuick®. Methods This was a operational retrospective research of HIV testing and questionnaire data collected in 2010 as part of the ZAMSTAR (Zambia South Africa TB and AIDS reduction) study. Randomly sampled individuals in twelve communities were tested consecutively with OraQuick® test using oral fluid versus two blood-based rapid HIV tests, Determine® and Uni-GoldTM. A cost analysis of four algorithms from health systems perspective were performed: 1) Determine® and if positive, then Uni-GoldTM (Determine®/Uni-GoldTM); based on current algorithm, 2) Determine® and if positive, then OraQuick® (Determine®/OraQuick®), 3) OraQuick® and if positive, then Determine® (OraQuick®/Determine®), 4) OraQuick® and if positive, then Uni-GoldTM (OraQuick®/Uni-GoldTM). This information was then used to construct a model using a hypothetical population of 5,000 persons with varying prevalence of HIV infection from 1–30%. Results 4,458 participants received both a Determine® and OraQuick® test. The sensitivity and specificity of the OraQuick® test were 98.7 (95%CI, 97.5–99.4) and 99.8 (95%CI, 99.6–99.9), respectively when compared to HIV positive serostatus. The average unit costs per algorithm were US$3.76, US$4.03, US$7.35, and US$7.67 for Determine®/Uni-GoldTM, Determine®/OraQuick®, OraQuick®/Determine®, and OraQuick®/Uni-GoldTM, respectively, for an HIV prevalence of 15%. Conclusions An alternative HIV testing algorithm could include OraQuick® test which had a high sensitivity and specificity. The current Determine®/Uni-GoldTM testing algorithm is the least expensive when compared to Determine®/OraQuick®, OraQuick®/Determine®, and OraQuick®/Uni-GoldTM in the Zambian setting. From our field experience, oral fluid based testing offers many advantages over blood-based testing, especially with self testing on the horizon. PMID:22871032

  12. GPCR-I-TASSER: A Hybrid Approach to G Protein-Coupled Receptor Structure Modeling and the Application to the Human Genome.

    PubMed

    Zhang, Jian; Yang, Jianyi; Jang, Richard; Zhang, Yang

    2015-08-04

    Experimental structure determination remains difficult for G protein-coupled receptors (GPCRs). We propose a new hybrid protocol to construct GPCR structure models that integrates experimental mutagenesis data with ab initio transmembrane (TM) helix assembly simulations. The method was tested on 24 known GPCRs where the ab initio TM-helix assembly procedure constructed the correct fold for 20 cases. When combined with weak homology and sparse mutagenesis restraints, the method generated correct folds for all the tested cases with an average Cα root-mean-square deviation 2.4 Å in the TM regions. The new hybrid protocol was applied to model all 1,026 GPCRs in the human genome, where 923 have a high confidence score and are expected to have correct folds; these contain many pharmaceutically important families with no previously solved structures, including Trace amine, Prostanoids, Releasing hormones, Melanocortins, Vasopressin, and Neuropeptide Y receptors. The results demonstrate new progress on genome-wide structure modeling of TM proteins. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Comparing self- and provider-collected swabbing for HPV DNA testing in female-to-male transgender adult patients: a mixed-methods biobehavioral study protocol.

    PubMed

    Reisner, Sari L; Deutsch, Madeline B; Peitzmeier, Sarah M; White Hughto, Jaclyn M; Cavanaugh, Timothy; Pardee, Dana J; McLean, Sarah; Marrow, Elliot J; Mimiaga, Matthew J; Panther, Lori; Gelman, Marcy; Green, Jamison; Potter, Jennifer

    2017-06-23

    Cervical cancer, nearly all cases of which are caused by one of several high-risk strains of the human papillomavirus (hr-HPV), leads to significant morbidity and mortality in individuals with a cervix. Trans masculine (TM) individuals were born with female reproductive organs and identify as male, man, transgender man, or another diverse gender identity different from their female assigned sex at birth. Routine preventive sexual health screening of TM patients is recommended, including screening for cervical cancer and other sexually transmitted infections (STIs); however, as many as one in three TM patients are not up-to-date per recommended U.S. Among cisgender (non-transgender) women, self-swab hr.-HPV DNA testing as a primary cervical cancer screening method and self-swab specimen collection for other STIs have high levels of acceptability. No study has yet been conducted to compare the performance and acceptability of self- and provider-collected swabs for hr.-HPV DNA testing and other STIs in TM patients. This article describes the study protocol for a mixed-methods biobehavioral investigation enrolling 150 sexually active TM to (1) assess the clinical performance and acceptability of a vaginal self-swab for hr.-HPV DNA testing compared to provider cervical swab and cervical cytology, and (2) gather acceptability data on self-collected specimens for other STIs. Study participation entails a one-time clinical visit at Fenway Health in Boston, MA comprised of informed consent, quantitative assessment, venipuncture for syphilis testing and HIV (Rapid OraQuick) testing, randomization, collection of biological specimens/biomarkers, participant and provider satisfaction survey, and qualitative exit interview. Participants are compensated $100. The primary study outcomes are concordance (kappa statistic) and performance (sensitivity and specificity) of self-collected vaginal HPV DNA specimens vs provider-collected cervical HPV swabs as a gold standard. This study addresses critical gaps in current clinical knowledge of sexual health in TM patients, including comparing alternative strategies for screening and diagnosis of cervical cancer, hr.-HPV, and other STIs. Findings have implications for improving the delivery of sexual health screening to this often overlooked and underserved patient population. Less-invasive patient-centered strategies may also generalize to other at-risk cisgender female populations that face barriers to timely and needed STI and cervical cancer screening. ClinicalTrials.gov ID: NCT02401867.

  14. Next-generation text-mining mediated generation of chemical response-specific gene sets for interpretation of gene expression data

    PubMed Central

    2013-01-01

    Background Availability of chemical response-specific lists of genes (gene sets) for pharmacological and/or toxic effect prediction for compounds is limited. We hypothesize that more gene sets can be created by next-generation text mining (next-gen TM), and that these can be used with gene set analysis (GSA) methods for chemical treatment identification, for pharmacological mechanism elucidation, and for comparing compound toxicity profiles. Methods We created 30,211 chemical response-specific gene sets for human and mouse by next-gen TM, and derived 1,189 (human) and 588 (mouse) gene sets from the Comparative Toxicogenomics Database (CTD). We tested for significant differential expression (SDE) (false discovery rate -corrected p-values < 0.05) of the next-gen TM-derived gene sets and the CTD-derived gene sets in gene expression (GE) data sets of five chemicals (from experimental models). We tested for SDE of gene sets for six fibrates in a peroxisome proliferator-activated receptor alpha (PPARA) knock-out GE dataset and compared to results from the Connectivity Map. We tested for SDE of 319 next-gen TM-derived gene sets for environmental toxicants in three GE data sets of triazoles, and tested for SDE of 442 gene sets associated with embryonic structures. We compared the gene sets to triazole effects seen in the Whole Embryo Culture (WEC), and used principal component analysis (PCA) to discriminate triazoles from other chemicals. Results Next-gen TM-derived gene sets matching the chemical treatment were significantly altered in three GE data sets, and the corresponding CTD-derived gene sets were significantly altered in five GE data sets. Six next-gen TM-derived and four CTD-derived fibrate gene sets were significantly altered in the PPARA knock-out GE dataset. None of the fibrate signatures in cMap scored significant against the PPARA GE signature. 33 environmental toxicant gene sets were significantly altered in the triazole GE data sets. 21 of these toxicants had a similar toxicity pattern as the triazoles. We confirmed embryotoxic effects, and discriminated triazoles from other chemicals. Conclusions Gene set analysis with next-gen TM-derived chemical response-specific gene sets is a scalable method for identifying similarities in gene responses to other chemicals, from which one may infer potential mode of action and/or toxic effect. PMID:23356878

  15. Methods of Evaluating Protective Clothing Relative to Heat and Cold Stress: Thermal Manikin, Biomedical Modeling, and Human Testing

    DTIC Science & Technology

    2011-01-01

    in the climatic chamber housing the manikin. The most widely accepted test procedures for the operation of a TM are published by ASTM International...insulation value of a complete clothing ensemble. It requires a TM surface temperature of 35◦C and a climatic chamber controlled at 23◦C, 50% relative... climatic chamber controlled at 35◦C, 40% relative humidity, with a 0.4 m/sec air velocity. In addition to the tests conducted at 0.4 m/sec, USARIEM

  16. Vibration of the human tympanic membrane measured with OCT in a range between 0.4 kHz and 6.4 kHz on an ex vivo sample

    NASA Astrophysics Data System (ADS)

    Burkhardt, Anke; Kirsten, Lars; Bornitz, Matthias; Zahnert, Thomas; Koch, Edmund

    2013-06-01

    Vibrations of the tympanic membrane (TM) play a key role for the transmission of sound to the inner ear. Today, there exist still problems in measuring the movement of the TM and there are unresolved issues in understanding the TM and its behavior. A non-invasive and contact-free in vivo investigation of the structure and the functional behavior of the TM would be a big step forward. In the presented study, the suitability of optical coherence tomography (OCT) for measuring the oscillation patterns of the TM in the frequency range covering the range of the human speech perception should be tested. For functional imaging a sound chirp was generated in the frequency range between 0.4 kHz - 6.4 kHz. To obtain the movement within a sufficient resolution, a grid of 25 x 25 measurement points was generated over the whole TM. The information of the oscillatory movement was encoded in the Doppler signal, provided by M-scans at several points of the TM. The frequency response functions of each frequency showed different oscillation patterns on the TM. The acquisition time of one single M-scan was only 8.5 ms and of the entire TM 5.3 s, emphasizing the potential of the method for future in vivo applications. Furthermore, the morphology was acquired with the same OCT-system, showing the feasibility for structural imaging and differentiation between typical regions of the TM. Thus, OCT was shown as a suitable method for the simultaneous measurement of the functional and structural behavior of the TM.

  17. Test performance and acceptability of self- versus provider-collected swabs for high-risk HPV DNA testing in female-to-male trans masculine patients

    PubMed Central

    Deutsch, Madeline B.; Peitzmeier, Sarah M.; White Hughto, Jaclyn M.; Cavanaugh, Timothy P.; Pardee, Dana J.; McLean, Sarah A.; Panther, Lori A.; Gelman, Marcy; Mimiaga, Matthew J.; Potter, Jennifer E.

    2018-01-01

    Background High-risk human papillomavirus (hrHPV) causes virtually all cervical cancers. Trans masculine (TM) people (those assigned female at birth who identify with a gender other than female) have low uptake of conventional cervical cancer screening. Self-collected hrHPV DNA testing has high levels of acceptability among cisgender (non-transgender) females and may support increased cervical cancer screening uptake in TM individuals. Objective To assess the test performance and acceptability of self-collected vaginal specimens in comparison to provider-collected cervical swabs for hrHPV DNA detection in TM individuals ages 21–64 years. Methods Between March 2015-September 2016, 150 TM participants with a cervix (mean age = 27.5 years; SD = 5.7) completed a one-time study visit comprised of a self-report survey, self-collected vaginal HPV DNA swab, clinician-administered cervical HPV swab, and brief interview on acceptability of clinical procedures. Participants were randomized to complete either self- or provider-collection first to minimize ordering effects. Self- and provider-collected samples were tested for 13 hrHPV DNA types using a DNA Hybridization Assay. The primary outcome variable was the concordance (kappa statistic) and performance (sensitivity, specificity) of self-collected vaginal HPV DNA specimens versus provider-collected cervical HPV swabs as the gold standard. Results Of the 131 participants completing both the self- and provider-collected HPV tests, 21 cases of hrHPV were detected by the provider cervical swab (gold standard; 16.0% hrHPV prevalence); 15 of these cases were accurately detected by the self-collected vaginal swab (71.4% concordance) (Kappa = 0.75, 95% Confidence Interval [CI]: 0.59, 0.92; p<0.001). Compared to the provider-collected cervical hrHPV DNA sample (gold standard), the self-collected vaginal hrHPV DNA test demonstrated a sensitivity of 71.4% (95% CI: 0.52, 0.91; p = 0.0495) and specificity of 98.2% (95% CI: 0.96, 1.00; p<0.0001). Over 90% of participants endorsed a preference for the self-collected vaginal swab over provider-collected cervical swab. Conclusion Self-collected vaginal swabs are highly acceptable to TM as a means to test for hrHPV DNA. Test performance of this self-collection method for hrHPV detection in TM is consistent with previous studies in cisgender females. Self-collected vaginal swab testing for hrHPV DNA represents a reasonable and patient-centered strategy for primary cervical cancer screening in TM patients unwilling to undergo provider collection of specimens via speculum exam. PMID:29538411

  18. Cytotoxicity and cytokine expression induced by silorane and methacrylate-based composite resins

    PubMed Central

    LONGO, Daniele Lucca; PAULA-SILVA, Francisco Wanderley Garcia; FACCIOLI, Lucia Helena; GATÓN-HERNÁNDEZ, Patrícia Maria; de QUEIROZ, Alexandra Mussolino; da SILVA, Léa Assed Bezerra

    2016-01-01

    ABSTRACT The successful use of composite resins in Dentistry depends on physicochemical properties, but also on the biological compatibility of resins, because of the close association between pulp and dentin. Objective The aim of this study was to evaluate cytotoxicity and cytokine production induced by light-cured or non-light-cured methacrylate-based and silorane composite resins in RAW 264.7 macrophages. Material and Methods Cells were stimulated with the extracts from light-cured or non-light-cured composite resins. After incubation for 24 h, cytotoxicity was assessed with the lactate dehydrogenase (LDH) and methyl thiazolyl tetrazolium (MTT) assays, and total protein was quantified using the Lowry method. TNF-α detection was examined with an enzyme-linked immunosorbent assay (ELISA) conducted with cell supernatants after cell stimulation for 6, 12, and 24 h. Data were analyzed using one-way analysis of variance (ANOVA) and Tukey’s post hoc test (α=0.05). Results KaloreTM and FiltekTM Silorane were cytotoxic with or without light curing (p<0.05) after 24 h of incubation. KaloreTM stimulated the early production of TNF-α in comparison with control (p<0.05), whereas FiltekTM Silorane did not affect TNF-α levels after 6 and 12 h (p>0.05). However, after 24 h FiltekTM Silorane inhibited the production of TNF-α (p<0.05). Conclusions KaloreTM and FiltekTM Silorane were cytotoxic regardless of light curing. The extract obtained from KaloreTM after 15 days of incubation stimulated the production of TNF-α, unlike that obtained from FiltekTM Silorane. PMID:27556204

  19. Effects of Tube Processing on the Fatigue Life of Nitinol

    NASA Astrophysics Data System (ADS)

    Adler, Paul; Frei, Rudolf; Kimiecik, Michael; Briant, Paul; James, Brad; Liu, Chuan

    2018-03-01

    Nitinol tubes were manufactured from Standard Grade VIM-VAR ingots using Tube Manufacturing method "TM-1." Diamond-shaped samples were laser cut, shape set, then fatigued at 37 °C to 107 cycles. The 50, 5, and 1% probabilities of fracture were calculated as a function of number of cycles to fracture and compared with probabilities determined for fatigue data published by Robertson et al. (J Mech Behav Biomater 51:119-131, 2015). Robertson tested similar diamonds made from the same standard grade of Nitinol as in the current study, two other standard grades of Nitinol, and two high-purity grades of Nitinol expressly designed to improve fatigue life. Robertson's tubes were manufactured using Tube Manufacturing method "TM-2." Fatigue performance of TM-1 and TM-2 diamonds were compared: At 107 cycles, strain amplitudes corresponding to the three probabilities of fracture of the TM-1 diamonds were 2-3 times those of the TM-2 diamonds made from the same grade of Nitinol, and comparable to TM-2 diamonds made from the higher-purity materials. This difference is likely a result of the differences in tube manufacturing techniques and effects on resulting microstructures. Microstructural analyses of samples revealed a correlation between the median probability of fracture and median inclusion diameter that follows an inverse power-law function of the form y ≈ x -1.

  20. GPCR-I-TASSER: A hybrid approach to G protein-coupled receptor structure modeling and the application to the human genome

    PubMed Central

    Zhang, Jian; Yang, Jianyi; Jang, Richard; Zhang, Yang

    2015-01-01

    SUMMARY Experimental structure determination remains very difficult for G protein-coupled receptors (GPCRs). We propose a new hybrid protocol to construct GPCR structure models that integrates experimental mutagenesis data with ab initio transmembrane (TM) helix assembly simulations. The method was tested on 24 known GPCRs where the ab initio TM-helix assembly procedure constructed the correct fold for 20 cases. When combined with weak-homology and sparse mutagenesis restraints, the method generated correct folds for all the tested cases with an average C-alpha RMSD 2.4 Å in the TM-regions. The new hybrid protocol was applied to model all 1026 GPCRs in the human genome, where 923 have a high confidence score that are expected to have correct folds; these contain many pharmaceutically important families with no previously solved structures, including Trace amine, Prostanoids, Releasing hormones, Melanocortins, Vasopressin and Neuropeptide Y receptors. The results demonstrate new progress on genome-wide structure modeling of transmembrane proteins. PMID:26190572

  1. Comparison of two methods of visual magnification for removal of adhesive flash during bracket placement using two types of orthodontic bonding agents

    PubMed Central

    Alencar, Estefania Queiroga de Santana e; Nobrega, Maria de Lourdes Martins; Dametto, Fabio Roberto; dos Santos, Patrícia Bittencourt Dutra; Pinheiro, Fabio Henrique de Sá Leitão

    2016-01-01

    ABSTRACT Objective: This study aimed to evaluate the effectiveness of two methods of visual magnification (operating microscope and light head magnifying glass) for removal of composite flash around orthodontic metal brackets. Material and Methods: Brackets were bonded in the center of the clinical crown of sixty well-preserved human premolars. Half of the sample was bonded with conventional Transbond XT (3M Unitek TM, USA), whereas the other half was bonded with Transbond TM Plus Color Change (3M Unitek TM, USA). For each type of composite, the choice of method to remove the flash was determined by randomly distributing the teeth into the following subgroups: A (removal by naked eye, n = 10), B (removal with the aid of light head magnifying glass, under 4x magnification, n = 10), and C (removal with the aid of an operating microscope, under 40x magnification, n = 10). Brackets were debonded and teeth taken to a scanning electron microscope (SS-x-550, Shimadzu, Japan) for visualization of their buccal surface. Quantification of composite flash was performed with Image Pro Plus software, and values were compared by Kruskal-Wallis test and Dunn’s post-hoc test at 5% significance level. Results: Removal of pigmented orthodontic adhesive with the aid of light head magnifying glass proved, in general, to be advantageous in comparison to all other methods. Conclusion: There was no advantage in using Transbond TM Plus Color Change alone. Further studies are necessary to draw a more definitive conclusion in regards to the benefits of using an operating microscope. PMID:28125139

  2. The Speaking Section of the TOEFL iBT[TM] (SSTiBT): Test-Takers' Reported Strategic Behaviors. TOEFL iBT[TM] Research Report. RR-09-30

    ERIC Educational Resources Information Center

    Swain, Merrill; Huang, Li-Shih; Barkaoui, Khaled; Brooks, Lindsay; Lapkin, Sharon

    2009-01-01

    This study responds to the Test of English as a Foreign Language[TM] (TOEFL[R]) research agenda concerning the need to understand the processes and knowledge that test-takers utilize. Specifically, it investigates the strategic behaviors test-takers reported using when taking the Speaking section of the TOEFL iBT[TM] (SSTiBT). It also investigates…

  3. Next-generation text-mining mediated generation of chemical response-specific gene sets for interpretation of gene expression data.

    PubMed

    Hettne, Kristina M; Boorsma, André; van Dartel, Dorien A M; Goeman, Jelle J; de Jong, Esther; Piersma, Aldert H; Stierum, Rob H; Kleinjans, Jos C; Kors, Jan A

    2013-01-29

    Availability of chemical response-specific lists of genes (gene sets) for pharmacological and/or toxic effect prediction for compounds is limited. We hypothesize that more gene sets can be created by next-generation text mining (next-gen TM), and that these can be used with gene set analysis (GSA) methods for chemical treatment identification, for pharmacological mechanism elucidation, and for comparing compound toxicity profiles. We created 30,211 chemical response-specific gene sets for human and mouse by next-gen TM, and derived 1,189 (human) and 588 (mouse) gene sets from the Comparative Toxicogenomics Database (CTD). We tested for significant differential expression (SDE) (false discovery rate -corrected p-values < 0.05) of the next-gen TM-derived gene sets and the CTD-derived gene sets in gene expression (GE) data sets of five chemicals (from experimental models). We tested for SDE of gene sets for six fibrates in a peroxisome proliferator-activated receptor alpha (PPARA) knock-out GE dataset and compared to results from the Connectivity Map. We tested for SDE of 319 next-gen TM-derived gene sets for environmental toxicants in three GE data sets of triazoles, and tested for SDE of 442 gene sets associated with embryonic structures. We compared the gene sets to triazole effects seen in the Whole Embryo Culture (WEC), and used principal component analysis (PCA) to discriminate triazoles from other chemicals. Next-gen TM-derived gene sets matching the chemical treatment were significantly altered in three GE data sets, and the corresponding CTD-derived gene sets were significantly altered in five GE data sets. Six next-gen TM-derived and four CTD-derived fibrate gene sets were significantly altered in the PPARA knock-out GE dataset. None of the fibrate signatures in cMap scored significant against the PPARA GE signature. 33 environmental toxicant gene sets were significantly altered in the triazole GE data sets. 21 of these toxicants had a similar toxicity pattern as the triazoles. We confirmed embryotoxic effects, and discriminated triazoles from other chemicals. Gene set analysis with next-gen TM-derived chemical response-specific gene sets is a scalable method for identifying similarities in gene responses to other chemicals, from which one may infer potential mode of action and/or toxic effect.

  4. New test method for the evaluation of the preservation efficacy of soaps at very alkaline pH made by saponification.

    PubMed

    Témoin-Fardini, S; Servant, J; Sellam, S

    2017-10-01

    The aim of this study was to develop a test method to evaluate the preservation efficacy for a specific product, a very high-alkaline liquid soap (pH around 10) made by a saponification process. Several manufacturers have experienced contamination issues with these high-pH soaps despite passing a classic preservative efficacy challenge test or even a multi-inoculation challenge test. Bacteria were isolated from contaminated soaps and were identified using 16S rRNA gene sequencing. High-alkaline-pH unpreserved soaps were tested using the Thor Personal Care internal multichallenge test method (TM206) with classical microorganisms and then with the bacterial strains isolated from various contaminated soaps (TM768). Preservatives were added to these soaps and assessed for their efficacy using the newly developed test. Four different species of bacteria (Nesterenkonia lacusekhoensis, Dermacoccus sp., Halomonas sp. and Roseomonas sp.) were identified by sequencing among the contaminants of the various soaps tested. Among these, only one bacterial species, Nesterenkonia lacusekhoensis, appeared to be responsible for the specific contamination of these high-alkaline soaps. Thus, one specific wild-type strain of Nesterenkonia lacusekhoensis, named as strain 768, was used in a new multi-inoculation test (TM768). Unlike the single inoculation challenge test, the multi-inoculation test using the Nesterenkonia strain 768 was able to predict the sensitivity of a product towards this bacterium. Among the 27 different preservatives tested, 10 were able to protect the formula against contamination with this bacterium. This study enabled the development of a test method to evaluate the efficacy of preservation using a specific bacterium, Nesterenkonia lacusekhoensis, responsible for the contamination of very alkaline soaps made by saponification and identify an appropriate preservative system. © 2017 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  5. Effects of consecutive trials and test-retest reliability of 1000-Hz tympanometry in adults.

    PubMed

    Carazo, Carla Dominguez; Sun, Xiao-Ming

    2015-04-01

    To investigate the effect of consecutive 1000-Hz tympanometry testing on admittance measures, and examine test-retest reliability. Repeated measures with eight trials of 1000-Hz Y(a) and B(a)/G(a) tympanometry, respectively, in two ears of each subject, followed by repeated 226-Hz tympanometry. Twenty-seven normal-hearing young adults. For single-peak tympanograms, peak Y(tm) and G(tm) systematically increased across trials with a mean change of 8% and 15% at Trial 8, respectively, whereas B(tm) increased marginally. For notched tympanograms, peak Y(tm) and B(tm) decreased by 23% and 162% at Trial 8, and G(tm) in two cases also decreased (10% on average). Trial 2 and 3 contributed 50% to 70% of the total changes. Test-retest differences of subsequently acquired 1000- and 226-Hz tympanograms were smaller than previously reported. Consecutive testing significantly alters middle-ear admittance in 1000-Hz tympanometry. The outcome is contingent on tympanogram pattern and admittance component: Increase of peak Y(tm) and G(tm) in single-peak tympanograms and decrease of all measures in notched tympanograms. The present results complement previous studies on our understanding of the mechanism underlying this effect: a decrease of middle-ear stiffness. The effect of repetitive tympanometry should be accounted for in research involving sequential testing.

  6. Cytotoxicity and cytokine expression induced by silorane and methacrylate-based composite resins.

    PubMed

    Longo, Daniele Lucca; Paula-Silva, Francisco Wanderley Garcia; Faccioli, Lucia Helena; Gatón-Hernández, Patrícia Maria; Queiroz, Alexandra Mussolino de; Silva, Léa Assed Bezerra da

    2016-01-01

    The aim of this study was to evaluate cytotoxicity and cytokine production induced by light-cured or non-light-cured methacrylate-based and silorane composite resins in RAW 264.7 macrophages. Cells were stimulated with the extracts from light-cured or non-light-cured composite resins. After incubation for 24 h, cytotoxicity was assessed with the lactate dehydrogenase (LDH) and methyl thiazolyl tetrazolium (MTT) assays, and total protein was quantified using the Lowry method. TNF-α detection was examined with an enzyme-linked immunosorbent assay (ELISA) conducted with cell supernatants after cell stimulation for 6, 12, and 24 h. Data were analyzed using one-way analysis of variance (ANOVA) and Tukey's post hoc test (α=0.05). KaloreTM and FiltekTM Silorane were cytotoxic with or without light curing (p<0.05) after 24 h of incubation. KaloreTM stimulated the early production of TNF-α in comparison with control (p<0.05), whereas FiltekTM Silorane did not affect TNF-α levels after 6 and 12 h (p>0.05). However, after 24 h FiltekTM Silorane inhibited the production of TNF-α (p<0.05). KaloreTM and FiltekTM Silorane were cytotoxic regardless of light curing. The extract obtained from KaloreTM after 15 days of incubation stimulated the production of TNF-α, unlike that obtained from FiltekTM Silorane.

  7. Design of a Channel Error Simulator using Virtual Instrument Techniques for the Initial Testing of TCP/IP and SCPS Protocols

    NASA Technical Reports Server (NTRS)

    Horan, Stephen; Wang, Ru-Hai

    1999-01-01

    There exists a need for designers and developers to have a method to conveniently test a variety of communications parameters for an overall system design. This is no different when testing network protocols as when testing modulation formats. In this report, we discuss a means of providing a networking test device specifically designed to be used for space communications. This test device is a PC-based Virtual Instrument (VI) programmed using the LabVIEW(TM) version 5 software suite developed by National Instruments(TM)TM. This instrument was designed to be portable and usable by others without special, additional equipment. The programming was designed to replicate a VME-based hardware module developed earlier at New Mexico State University (NMSU) and to provide expanded capabilities exceeding the baseline configuration existing in that module. This report describes the design goals for the VI module in the next section and follows that with a description of the design of the VI instrument. This is followed with a description of the validation tests run on the VI. An application of the error-generating VI to networking protocols is then given.

  8. Test performance and acceptability of self- versus provider-collected swabs for high-risk HPV DNA testing in female-to-male trans masculine patients.

    PubMed

    Reisner, Sari L; Deutsch, Madeline B; Peitzmeier, Sarah M; White Hughto, Jaclyn M; Cavanaugh, Timothy P; Pardee, Dana J; McLean, Sarah A; Panther, Lori A; Gelman, Marcy; Mimiaga, Matthew J; Potter, Jennifer E

    2018-01-01

    High-risk human papillomavirus (hrHPV) causes virtually all cervical cancers. Trans masculine (TM) people (those assigned female at birth who identify with a gender other than female) have low uptake of conventional cervical cancer screening. Self-collected hrHPV DNA testing has high levels of acceptability among cisgender (non-transgender) females and may support increased cervical cancer screening uptake in TM individuals. To assess the test performance and acceptability of self-collected vaginal specimens in comparison to provider-collected cervical swabs for hrHPV DNA detection in TM individuals ages 21-64 years. Between March 2015-September 2016, 150 TM participants with a cervix (mean age = 27.5 years; SD = 5.7) completed a one-time study visit comprised of a self-report survey, self-collected vaginal HPV DNA swab, clinician-administered cervical HPV swab, and brief interview on acceptability of clinical procedures. Participants were randomized to complete either self- or provider-collection first to minimize ordering effects. Self- and provider-collected samples were tested for 13 hrHPV DNA types using a DNA Hybridization Assay. The primary outcome variable was the concordance (kappa statistic) and performance (sensitivity, specificity) of self-collected vaginal HPV DNA specimens versus provider-collected cervical HPV swabs as the gold standard. Of the 131 participants completing both the self- and provider-collected HPV tests, 21 cases of hrHPV were detected by the provider cervical swab (gold standard; 16.0% hrHPV prevalence); 15 of these cases were accurately detected by the self-collected vaginal swab (71.4% concordance) (Kappa = 0.75, 95% Confidence Interval [CI]: 0.59, 0.92; p<0.001). Compared to the provider-collected cervical hrHPV DNA sample (gold standard), the self-collected vaginal hrHPV DNA test demonstrated a sensitivity of 71.4% (95% CI: 0.52, 0.91; p = 0.0495) and specificity of 98.2% (95% CI: 0.96, 1.00; p<0.0001). Over 90% of participants endorsed a preference for the self-collected vaginal swab over provider-collected cervical swab. Self-collected vaginal swabs are highly acceptable to TM as a means to test for hrHPV DNA. Test performance of this self-collection method for hrHPV detection in TM is consistent with previous studies in cisgender females. Self-collected vaginal swab testing for hrHPV DNA represents a reasonable and patient-centered strategy for primary cervical cancer screening in TM patients unwilling to undergo provider collection of specimens via speculum exam.

  9. IPMC paints

    NASA Astrophysics Data System (ADS)

    Park, Il-Seok; Tiwari, Rashi; Kim, Kwang J.

    2008-03-01

    In this paper we are reporting a newely developed IPMC fabrication method, "IPMC Paint", which can be directly sprayed onto any complex surface. In order to fabricate the IPMC paint, liquid Nafion TM was used for the ionic conducting polymer instead of the typical film/sheet type Nafion TM. The viscosity of liquid Nafion TM was adjusted by adding Polyvinylpyrrolidone (PVP) to perform spray painting. Modified Nafion was sprayed onto the conducting substrate, Polyfoil TM which acts as base electrode layer. After three times spraying, ionic polymer layer has 45 μm thickness and 10 μm of surface roughness. Sensing tests show that IPMC paint sensor has more sensitivity (+/- 0.06 of producing voltage) than that of the typical IPMC (+/- 0.005 of producing voltage) when dynamic bending with 10 Hz frequency and 1.3 cm of displacement is applied to.

  10. A One-Piece Lunar Regolith Bag Garage Prototype

    NASA Technical Reports Server (NTRS)

    Smithers, G. A.; Nehls, M. K.; Hovater, M. A.; Evans, S. W.; Miller, J. S.; Broughton, R. M., Jr.; Beale, D.; Kilinc-Balci, F.

    2007-01-01

    Shelter structures on the moon, even in early phases of exploration, should incorporate lunar materials as much as possible. This Technical Memorandum details the design and construction of a prototype for a one-piece regolith bag unpressurized garage concept and a materials testing program to investigate six candidate fabrics to learn how they might perform in the lunar environment. The conceptualization was that a lightweight fabric form be launched from Earth and landed on the lunar surface to be robotically filled with raw lunar regolith. Regolith bag fabric candidates included: Vectran(TM), Nextel(TM), Gore PTFE Fabric(TM), Zylon(TM), Twaron(TM), and Nomex(TM). Tensile (including post radiation exposure), fold, abrasion, and hypervelocity impact testing were performed under ambient conditions, and also performed under cold and elevated temperatures. In some cases, Johnson Space Center lunar simulant (JSC-1) was used in conjunction with testing. A series of preliminary structures was constructed during final prototype design based on the principles of the classic masonry arch. The prototype was constructed of Kevlar(TM) and filled with vermiculite. The structure is free-standing, but has not yet been load tested. Future plans would be to construct higher fidelity prototypes and to conduct appropriate tests of the structure.

  11. Genetic characterization and improved genotyping of the dysferlin-deficient mouse strain Dysf (tm1Kcam).

    PubMed

    Wiktorowicz, Tatiana; Kinter, Jochen; Kobuke, Kazuhiro; Campbell, Kevin P; Sinnreich, Michael

    2015-01-01

    Mouse models of dysferlinopathies are valuable tools with which to investigate the pathomechanisms underlying these diseases and to test novel therapeutic strategies. One such mouse model is the Dysf (tm1Kcam) strain, which was generated using a targeting vector to replace a 12-kb region of the dysferlin gene and which features a progressive muscular dystrophy. A prerequisite for successful animal studies using genetic mouse models is an accurate genotyping protocol. Unfortunately, the lack of robustness of currently available genotyping protocols for the Dysf (tm1Kcam) mouse has prevented efficient colony management. Initial attempts to improve the genotyping protocol based on the published genomic structure failed. These difficulties led us to analyze the targeted locus of the dysferlin gene of the Dysf (tm1Kcam) mouse in greater detail. In this study we resequenced and analyzed the targeted locus of the Dysf (tm1Kcam) mouse and developed a novel PCR protocol for genotyping. We found that instead of a deletion, the dysferlin locus in the Dysf (tm1Kcam) mouse carries a targeted insertion. This genetic characterization enabled us to establish a reliable method for genotyping of the Dysf (tm1Kcam) mouse, and thus has made efficient colony management possible. Our work will make the Dysf (tm1Kcam) mouse model more attractive for animal studies of dysferlinopathies.

  12. What Is the Reference? An Examination of Alternatives to the Reference Sources Used in IES TM-30-15

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Royer, Michael P.

    A study was undertaken to document the role of the reference illuminant in the IES TM-30-15 method for evaluating color rendition. TM-30-15 relies on a relative reference scheme; that is, the reference illuminant and test source always have the same correlated color temperature (CCT). The reference illuminant is a Planckian radiator, model of daylight, or combination of those two, depending on the exact CCT of the test source. Three alternative reference schemes were considered: 1) either using all Planckian radiators or all daylight models; 2) using only one of ten possible illuminants (Planckian, daylight, or equal energy), regardless of themore » CCT of the test source; 3) using an off-Planckian reference illuminant (i.e., a source with a negative Duv). No reference scheme is inherently superior to another, with differences in metric values largely a result of small differences in gamut shape of the reference alternatives. While using any of the alternative schemes is more reasonable in the TM-30-15 evaluation framework than it was with the CIE CRI framework, the differences still ultimately manifest only as changes in interpretation of the results. References are employed in color rendering measures to provide a familiar point of comparison, not to establish an ideal source.« less

  13. Dynamic Properties of Human Tympanic Membrane Based on Frequency-Temperature Superposition

    PubMed Central

    Zhang, Xiangming; Gan, Rong Z.

    2012-01-01

    The human tympanic membrane (TM) transfers sound in the ear canal into the mechanical vibration of the ossicles in the middle ear. The dynamic properties of TM directly affect the middle ear transfer function. The static or quasi-static mechanical properties of TM were reported in the literature, but the dynamic properties of TM over the auditory frequency range are very limited. In this paper, a new method was developed to measure the dynamic properties of human TM using the Dynamic-Mechanical Analyzer (DMA). The test was conducted at the frequency range of 1 to 40 Hz at three different temperatures: 5°, 25° and 37°C. The frequency-temperature superposition was applied to extend the testing frequency range to a much higher level (at least 3800 Hz). The generalized linear solid model was employed to describe the constitutive relation of the TM. The storage modulus E’ and the loss modulus E” were obtained from 11 specimens. The mean storage modulus was 15.1 MPa at 1 Hz and 27.6 MPa at 3800 Hz. The mean loss modulus was 0.28 MPa at 1 Hz and 4.1 MPa at 3800 Hz. The results show that the frequency-temperature superposition is a feasible approach to study the dynamic properties of the ear soft tissues. The dynamic properties of human TM obtained in this study provide a better description of the damping behavior of ear tissues. The properties can be transferred into the finite element (FE) model of the human ear to replace the Rayleigh type damping. The data reported here contribute to the biomechanics of the middle ear and improve the accuracy of the FE model for the human ear. PMID:22820983

  14. AN ANGIOTENSIN II TYPE 1 RECEPTOR ACTIVATION SWITCH PATCH REVEALED THROUGH EVOLUTIONARY TRACE ANALYSIS

    PubMed Central

    Bonde, Marie Mi; Yao, Rong; Ma, Jian-Nong; Madabushi, Srinivasan; Haunsø, Stig; Burstein, Ethan S.; Whistler, Jennifer L.; Sheikh, Søren P.; Lichtarge, Olivier; Hansen, Jakob Lerche

    2010-01-01

    Seven transmembrane (7TM) or G protein-coupled receptors constitute a large superfamily of cell surface receptors sharing a structural motif of seven transmembrane spanning alpha helices. Their activation mechanism most likely involves concerted movements of the transmembrane helices, but remains to be completely resolved. Evolutionary Trace (ET) analysis is a computational method, which identifies clusters of functionally important residues by integrating information on evolutionary important residue variations with receptor structure. Combined with known mutational data, ET predicted a patch of residues in the cytoplasmic parts of TM2, TM3, and TM6 to form an activation switch that is common to all family A 7TM receptors. We tested this hypothesis in the rat Angiotensin II (Ang II) type 1 (AT1) receptor. The receptor has important roles in the cardiovascular system, but has also frequently been applied as a model for 7TM receptor activation and signaling. Six mutations: F66A, L67R, L70R, L119R, D125A, and I245F were targeted to the putative switch and assayed for changes in activation state by their ligand binding, signaling, and trafficking properties. All but one receptor mutant (that was not expressed well) displayed phenotypes associated with changed activation state, such as increased agonist affinity or basal activity, promiscuous activation, or constitutive internalization highlighting the importance of testing different signaling pathways. We conclude that this evolutionary important patch mediates interactions important for maintaining the inactive state. More broadly, these observations in the AT1 receptor are consistent with computational predictions of a generic role for this patch in 7TM receptor activation. PMID:20227396

  15. A One-Piece Lunar Regolith-Bag Garage Prototype

    NASA Technical Reports Server (NTRS)

    Smithers, Gweneth A.; Nehls, Mary K.; Hovater, Mary A.; Evans, Steven W.; Miller, J. Scott; Broughton, Roy M., Jr.; Beale, David; Killinc-Balci, Fatma

    2006-01-01

    Shelter structures on the moon, even in early phases of exploration, should incorporate lunar materials as much as possible. We designed and constructed a prototype for a one-piece regolith-bag unpressurized garage concept, and, in parallel, we conducted a materials testing program to investigate six candidate fabrics to learn how they might perform in the lunar environment. In our concept, a lightweight fabric form is launched from Earth to be landed on the lunar surface and robotically filled with raw lunar regolith. In the materials testing program, regolith-bag fabric candidates included: VectranTM, NextelTM, Gore PTFE FabricTM, ZylonTM TwaronTM and NomexTM. Tensile (including post radiation exposure), fold, abrasion, and hypervelocity impact testing were performed under ambient conditions, and, within our current means, we also performed these tests under cold and elevated temperatures. In some cases, lunar simulant (JSC-1) was used in conjunction with testing. Our ambition is to continuously refine our testing to reach lunar environmental conditions to the extent possible. A series of preliminary structures were constructed during design of the final prototype. Design is based on the principles of the classic masonry arch. The prototype was constructed of KevlarTM and filled with vermiculite (fairly close to the weight of lunar regolith on the moon). The structure is free-standing, but has not yet been load tested. Our plan for the future would be to construct higher fidelty mockups with each iteration, and to conduct appropriate tests of the structure.

  16. A One-Piece Lunar Regolith-Bag Garage Prototype

    NASA Technical Reports Server (NTRS)

    Smithers, Gweneth A.; Nehls, Mary K.; Hovater, Mary A.; Evans, Steven W.; Miller, J. Scott; Broughton, Roy M.; Beale, David; Killing-Balci, Fatma

    2007-01-01

    Shelter structures on the moon, even in early phases of exploration, should incorporate lunar materials as much as possible. We designed and constructed a prototype for a one-piece regolith-bag unpressurized garage concept, and, in parallel, we conducted a materials testing program to investigate six candidate fabrics to learn how they might perform in the lunar environment. In our concept, a lightweight fabric form is launched from Earth to be landed on the lunar surface and robotically filled with raw lunar regolith. In the materials testing program, regolith-bag fabric candidates included: Vectran(TM), Nextel(TM), Gore PTFE Fabric(TM), Zylon(TM), Twaron(TM), and Nomex(TM). Tensile (including post radiation exposure), fold, abrasion, and hypervelocity impact testing were performed under ambient conditions, and, within our current means, we also performed these tests under cold and elevated temperatures. In some cases, lunar simulant (JSC-1) was used in conjunction with testing. Our ambition is to continuously refine our testing to reach lunar environmental conditions to the extent possible. A series of preliminary structures were constructed during design of the final prototype. Design is based on the principles of the classic masonry arch. The prototype was constructed of Kevlar(TM) and filled with vermiculite (fairly close to the weight of lunar regolith on the moon). The structure is free-standing, but has not yet been load tested. Our plan for the future would be to construct higher fidelity mockups with each iteration, and to conduct appropriate tests of the structure.

  17. Influence of Three Different Methods of Teaching Physics on the Gain in Students' Development of Reasoning

    ERIC Educational Resources Information Center

    Marusic, Mirko; Slisko, Josip

    2012-01-01

    The Lawson Classroom Test of Scientific Reasoning (LCTSR) was used to gauge the relative effectiveness of three different methods of pedagogy, "Reading, Presenting, and Questioning" (RPQ), "Experimenting and Discussion" (ED), and "Traditional Methods" (TM), on increasing students' level of scientific thinking. The…

  18. Transmembrane helix prediction: a comparative evaluation and analysis.

    PubMed

    Cuthbertson, Jonathan M; Doyle, Declan A; Sansom, Mark S P

    2005-06-01

    The prediction of transmembrane (TM) helices plays an important role in the study of membrane proteins, given the relatively small number (approximately 0.5% of the PDB) of high-resolution structures for such proteins. We used two datasets (one redundant and one non-redundant) of high-resolution structures of membrane proteins to evaluate and analyse TM helix prediction. The redundant (non-redundant) dataset contains structure of 434 (268) TM helices, from 112 (73) polypeptide chains. Of the 434 helices in the dataset, 20 may be classified as 'half-TM' as they are too short to span a lipid bilayer. We compared 13 TM helix prediction methods, evaluating each method using per segment, per residue and termini scores. Four methods consistently performed well: SPLIT4, TMHMM2, HMMTOP2 and TMAP. However, even the best methods were in error by, on average, about two turns of helix at the TM helix termini. The best and worst case predictions for individual proteins were analysed. In particular, the performance of the various methods and of a consensus prediction method, were compared for a number of proteins (e.g. SecY, ClC, KvAP) containing half-TM helices. The difficulties of predicting half-TM helices suggests that current prediction methods successfully embody the two-state model of membrane protein folding, but do not accommodate a third stage in which, e.g., short helices and re-entrant loops fold within a bundle of stable TM helices.

  19. Clinical outcomes in patients with metastatic renal cell carcinoma receiving everolimus or temsirolimus after sunitinib

    PubMed Central

    Iacovelli, Roberto; Cartenì, Giacomo; Milella, Michele; Berardi, Rossana; Di Lorenzo, Giuseppe; Verzoni, Elena; Rizzo, Mimma; Santoni, Matteo; Procopio, Giuseppe

    2014-01-01

    Introduction: There are little data on the clinical activity of temsirolimus (TM) and everolimus (EV) when used as second-line therapy after sunitinib (SU) in patients with metastatic renal cell carcinoma (mRCC). Methods: Patients with mRCC treated with EV or TM after SU were included in this retrospective analysis. Progression-free survival (PFS), time to sequence failure (TTSF) from the start of SU to disease progression with EV/TM and overall survival (OS) were estimated using Kaplan-Meier method and compared across groups using the log-rank test. Cox proportional hazards models were applied to investigate predictors of TTSF and OS. Results: In total, 89 patients (median age 60.0 years) were included. At baseline 43% were classified as MSKCC good-risk, 43% as intermediate-risk and 14% as poor-risk. Median OS was 36.3 months and median TTSF was 17.2 months. Sixty-five patients received SU-EV and 24 patients SU-TM. Median PFS after the second-line treatment was 4.3 months in the EV group and 3.5 months in the TM group (p = 0.63). Median TTSF was 17.0 and 18.9 months (p = 0.32) and the OS was 35.8 and 38.3 months (p = 0.73) with SU-EV and SU-TM, respectively. The prognostic role of initial MSKCC was confirmed by multivariable analysis (hazard ratio 1.76, 95% confidence interval 1.08–2.85. p = 0.023). Conclusions: This study did not show significant differences in terms of disease control and OS between EV and TM in the second-line setting. EV remains the preferred mTOR inhibitor for the treatment of mRCC patients resistant to prior tyrosine kinase inhibitor treatment. PMID:24678349

  20. LC-circuit calorimetry

    NASA Astrophysics Data System (ADS)

    Bossen, O.; Schilling, A.

    2011-09-01

    We present a new type of calorimeter in which we couple an unknown heat capacity with the aid of Peltier elements to an electrical circuit. The use of an electrical inductance and an amplifier in the circuit allows us to achieve autonomous oscillations, and the measurement of the corresponding resonance frequency makes it possible to accurately measure the heat capacity with an intrinsic statistical uncertainty that decreases as ˜ t_m^{ -3/2} with measuring time tm, as opposed to a corresponding uncertainty ˜ t_m^{-1/2} in the conventional alternating current method to measure heat capacities. We have built a demonstration experiment to show the feasibility of the new technique, and we have tested it on a gadolinium sample at its transition to the ferromagnetic state.

  1. The Tofts model in frequency domain: fast and robust determination of pharmacokinetic maps for dynamic contrast enhancement MRI

    NASA Astrophysics Data System (ADS)

    Vajuvalli, Nithin N.; Chikkemenahally, Dharmendra Kumar K.; Nayak, Krupa N.; Bhosale, Manoj G.; Geethanath, Sairam

    2016-12-01

    Dynamic contrast enhancement magnetic resonance imaging (DCE-MRI) is a well-established method for non-invasive detection and therapeutic monitoring of pathologies through administration of intravenous contrast agent. Quantification of pharmacokinetic (PK) maps can be achieved through application of compartmental models relevant to the pathophysiology of the tissue under interrogation. The determination of PK parameters involves fitting of time-concentration data to these models. In this work, the Tofts model in frequency domain (TM-FD) is applied to a weakly vascularized tissue such as the breast. It is derived as a convolution-free model from the conventional Tofts model in the time domain (TM-TD). This reduces the dimensionality of the curve-fitting problem from two to one. The approaches of TM-FD and TM-TD were applied to two kinds of in silico phantoms and six in vivo breast DCE data sets with and without the addition of noise. The results showed that computational time taken to estimate PK maps using TM-FD was 16-25% less than with TM-TD. Normalized root mean square error (NRMSE) calculation and Pearson correlation analyses were performed to validate robustness and accuracy of the TM-FD and TM-TD approaches. These compared with ground truth values in the case of phantom studies for four different temporal resolutions. Results showed that NRMSE values for TM-FD were significantly lower than those of TM-TD as validated by a paired t-test along with reduced computational time. This approach therefore enables online evaluation of PK maps by radiologists in a clinical setting, aiding in the evaluation of 3D and/or increased coverage of the tissue of interest.

  2. Diagnostic Accuracy of Virtual Pathology vs Traditional Microscopy in a Large Dermatopathology Study.

    PubMed

    Kent, Michael N; Olsen, Thomas G; Feeser, Theresa A; Tesno, Katherine C; Moad, John C; Conroy, Michael P; Kendrick, Mary Jo; Stephenson, Sean R; Murchland, Michael R; Khan, Ayesha U; Peacock, Elizabeth A; Brumfiel, Alexa; Bottomley, Michael A

    2017-12-01

    Digital pathology represents a transformative technology that impacts dermatologists and dermatopathologists from residency to academic and private practice. Two concerns are accuracy of interpretation from whole-slide images (WSI) and effect on workflow. Studies of considerably large series involving single-organ systems are lacking. To evaluate whether diagnosis from WSI on a digital microscope is inferior to diagnosis of glass slides from traditional microscopy (TM) in a large cohort of dermatopathology cases with attention on image resolution, specifically eosinophils in inflammatory cases and mitotic figures in melanomas, and to measure the workflow efficiency of WSI compared with TM. Three dermatopathologists established interobserver ground truth consensus (GTC) diagnosis for 499 previously diagnosed cases proportionally representing the spectrum of diagnoses seen in the laboratory. Cases were distributed to 3 different dermatopathologists who diagnosed by WSI and TM with a minimum 30-day washout between methodologies. Intraobserver WSI/TM diagnoses were compared, followed by interobserver comparison with GTC. Concordance, major discrepancies, and minor discrepancies were calculated and analyzed by paired noninferiority testing. We also measured pathologists' read rates to evaluate workflow efficiency between WSI and TM. This retrospective study was caried out in an independent, national, university-affiliated dermatopathology laboratory. Intraobserver concordance of diagnoses between WSI and TM methods and interobserver variance from GTC, following College of American Pathology guidelines. Mean intraobserver concordance between WSI and TM was 94%. Mean interobserver concordance was 94% for WSI and GTC and 94% for TM and GTC. Mean interobserver concordance between WSI, TM, and GTC was 91%. Diagnoses from WSI were noninferior to those from TM. Whole-slide image read rates were commensurate with WSI experience, achieving parity with TM by the most experienced user. Diagnosis from WSI was found equivalent to diagnosis from glass slides using TM in this statistically powerful study of 499 dermatopathology cases. This study supports the viability of WSI for primary diagnosis in the clinical setting.

  3. A Review of "Integrity[TM]"

    ERIC Educational Resources Information Center

    Veldkamp, Bernard P.

    2008-01-01

    Integrity[TM], an online application for testing both the statistical integrity of the test and the academic integrity of the examinees, was evaluated for this review. Program features and the program output are described. An overview of the statistics in Integrity[TM] is provided, and the application is illustrated with a small simulation study.…

  4. Automated symbolic calculations in nonequilibrium thermodynamics

    NASA Astrophysics Data System (ADS)

    Kröger, Martin; Hütter, Markus

    2010-12-01

    We cast the Jacobi identity for continuous fields into a local form which eliminates the need to perform any partial integration to the expense of performing variational derivatives. This allows us to test the Jacobi identity definitely and efficiently and to provide equations between different components defining a potential Poisson bracket. We provide a simple Mathematica TM notebook which allows to perform this task conveniently, and which offers some additional functionalities of use within the framework of nonequilibrium thermodynamics: reversible equations of change for fields, and the conservation of entropy during the reversible dynamics. Program summaryProgram title: Poissonbracket.nb Catalogue identifier: AEGW_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEGW_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 227 952 No. of bytes in distributed program, including test data, etc.: 268 918 Distribution format: tar.gz Programming language: Mathematica TM 7.0 Computer: Any computer running Mathematica TM 6.0 and later versions Operating system: Linux, MacOS, Windows RAM: 100 Mb Classification: 4.2, 5, 23 Nature of problem: Testing the Jacobi identity can be a very complex task depending on the structure of the Poisson bracket. The Mathematica TM notebook provided here solves this problem using a novel symbolic approach based on inherent properties of the variational derivative, highly suitable for the present tasks. As a by product, calculations performed with the Poisson bracket assume a compact form. Solution method: The problem is first cast into a form which eliminates the need to perform partial integration for arbitrary functionals at the expense of performing variational derivatives. The corresponding equations are conveniently obtained using the symbolic programming environment Mathematica TM. Running time: For the test cases and most typical cases in the literature, the running time is of the order of seconds or minutes, respectively.

  5. Metabolic responses associated with deer hunting.

    PubMed

    Peterson, A T; Steffen, J; Terry, L; Davis, J; Porcari, J P; Foster, C

    1999-12-01

    Deer hunting is a popular recreational activity with a high rate of cardiovascular events. Previous studies have demonstrated large HR responses during deer hunting. This study compared the HR and metabolic costs of maximal treadmill (TM) exercise with those of hiking while deer hunting and while dragging a deer. Healthy male volunteers (N = 16) performed a maximal TM exercise test, a 0.8-km hiking test, and a 0.4-km dragging test over lightly rolling terrain. VO2 was measured by portable spirometry and HR by radiotelemetry. HR averaged 74.0 +/- 7.0% and 89.1 +/- 4.5% of peak TM HR during the hike and drag, respectively. The peak HR observed during hiking and dragging was 83.2 +/- 6.0% and 94.9 +/- 4.2% of peak TM HR, respectively. VO2 averaged 62.2 +/- 15.8% and achieved a peak of 77.2 +/- 19.0% of TM VO2 while hiking. This corresponded to 86.8 +/- 17.3% and 108.1 +/- 22.3% of ventilatory threshold (VT), respectively. VO2 averaged 72.3 +/- 21.0% and achieved a peak of 91.2 +/- 21.4% of peak TM VO2 while dragging the deer. This corresponded to 101.5 +/- 27.7% and 128.5 +/- 26.8% of VT, respectively. The VO2/HR relationship showed significant (P < 0.05) difference between the dragging test and the TM test with a disproportionately high HR. The VO2/HR relationship between the hiking and TM tests was comparable. In part, the previously described large HR responses and high rate of cardiovascular complications associated with deer hunting may attributable to the elevated metabolic costs of associated activities.

  6. How Do Raters from India Perform in Scoring the TOEFL iBT[TM] Speaking Section and What Kind of Training Helps? TOEFL iBT[TM] Research Report. RR-09-31

    ERIC Educational Resources Information Center

    Xi, Xiaoming; Mollaun, Pam

    2009-01-01

    This study investigated the scoring of the Test of English as a Foreign Language[TM] Internet-based Test (TOEFL iBT[TM]) Speaking section by bilingual or multilingual speakers of English and 1 or more Indian languages. We explored the extent to which raters from India, after being trained and certified, were able to score the Speaking section for…

  7. Impact of Maple(TM) on the design, instruction and performance in an undergraduate physics mathematical methods course

    NASA Astrophysics Data System (ADS)

    Runge, Alan Paul

    1997-10-01

    A traditional undergraduate physics course on mathematical methods has been redesigned to incorporate the use of Maplesp{sc {TM}}, a computer algebra program, during all aspects of the course. Topics covered were: complex number theory; series approximations; matrix theory; partial differentiation; vector algebra; and vector calculus. Five undergraduate students were enrolled, from sophomore to senior in academic class standing. A qualitative case study methodology was used to describe the changes in the course design resulting from the incorporation of Maplesp{sc {TM}} and their impact on the instruction of the course, and to determine the effects on the students' learning and development of problem solving skills in physics using Maplesp{sc {TM}} as a problem solving tool. The impact of using Maplesp{sc {TM}} on the number and types of interactions is presented. The entire semester long course was included in this study. Each class session is described in detail. Examples of the Maplesp{sc {TM}} materials used are given. The use of the Maplesp{sc {TM}} program was allowed on all homework and exams with each student having their own computer during class. Constraints were made so that the assessment emphasis remained on the mathematics and the conceptual understanding of the problem solving methods. All of the students demonstrated some level of proficiency in using Maplesp{TM} to solve the assigned problems. Strategies for effectively using Maplesp{TM} were presented and were individualized by the students. The students reported positive and negative impacts of using Maplesp{sc {TM}}. All of the students satisfactorily completed the course requirements, receiving final course grades from B to A+. All of them continued to voluntarily use Maplesp{sc {TM}} during the following semester. Instructional methods used included various lecture techniques without Maplesp{sc {TM}} assistance, lectures and demonstrations using only Maplesp{sc {TM}}, and student tasks assigned in class worked with the aid of Maplesp{sc {TM}}. Maplesp{sc {TM}} was used in one of these aspects in all but 3, out of 45, class periods. The use of Maplesp{sc {TM}} constituted about half of the overall class time.

  8. Applying TM-polarization geoelectric exploration for study of low-contrast three-dimensional targets

    NASA Astrophysics Data System (ADS)

    Zlobinskiy, Arkadiy; Mogilatov, Vladimir; Shishmarev, Roman

    2018-03-01

    With using new field and theoretical data, it has been shown that applying the electromagnetic field of transverse magnetic (TM) polarization will give new opportunities for electrical prospecting by the method of transient processes. Only applying a pure field of the TM polarization permits poor three-dimensional objects (required metalliferous deposits) to be revealed in a host horizontally-layered medium. This position has good theoretical grounds. There is given the description of the transient electromagnetic method, that uses only the TM polarization field. The pure TM mode is excited by a special source, which is termed as a circular electric dipole (CED). The results of three-dimensional simulation (by the method of finite elements) are discussed for three real geological situations for which applying electromagnetic fields of transverse electric (TE) and transverse magnetic (TM) polarizations are compared. It has been shown that applying the TE mode gives no positive results, while applying the TM polarization field permits the problem to be tackled. Finally, the results of field works are offered, which showed inefficiency of application of the classical TEM method, whereas in contrast, applying the field of TM polarization makes it easy to identify the target.

  9. Therapeutic Misconception in Research Subjects: Development and Validation of a Measure

    PubMed Central

    Appelbaum, Paul S.; Anatchkova, Milena; Albert, Karen; Dunn, Laura B.; Lidz, Charles W.

    2013-01-01

    Background Therapeutic misconception (TM), which occurs when research subjects fail to appreciate the distinction between the imperatives of clinical research and ordinary treatment, may undercut the process of obtaining meaningful consent to clinical research participation. Previous studies have found TM is widespread, but progress in addressing TM has been stymied by the absence of a validated method for assessing its presence. Purpose The goal of this study was to develop and validate a theoretically grounded measure of TM, assess its diagnostic accuracy, and test previous findings regarding its prevalence. Methods 220 participants were recruited from clinical trials at 4 academic medical centers in the U.S. Participants completed a 28-item Likert-type questionnaire to assess the presence of beliefs associated with TM, and a semi-structured TM interview designed to elicit their perceptions of the nature of the clinical trial in which they were participating. Data from the questionnaires were subjected to factor analysis and items with poor factor loadings were excluded. This resulted in a 10-item scale, with 3 strongly correlated factors and excellent internal consistency; the fit indices of the model across 10 training sets were consistent with the original results, suggesting a stable factor solution. Results The scale was validated against the TM interview, with significantly higher scores among subjects coded as displaying evidence of TM. ROC analysis based on a 10-fold internal cross-validation yielded AUC=.682 for any evidence of TM. When sensitivity (0.72) and specificity (0.61) were both optimized, Positive Predictive Value was 0.65 and Negative Predictive Value was 0.68, with a Positive Likelihood Ratio of 1.89, and a Negative Likelihood Ratio of 0.47. 50.5% (n=101) of participants manifested evidence of TM on the TM interview, a somewhat lower rate than in most previous studies. Limitations The predictive value of the scale compared with the “gold standard” clinical interview is modest, although similar to other instruments based on self-report assessing states of mind rather than discrete symptoms. Thus, although the scale can offer evidence of which subjects are at risk for distortions in their decisions and to what degree, it will not allow researchers to conclude definitively that TM is present in a given subject. Conclusions The development of a reliable and valid TM scale, even with modest predictive power, should permit investigators in clinical trials to identify subjects with tendencies to misinterpret the nature of the situation and to provide additional information to them. It should also stimulate research on how best to decrease TM and facilitate meaningful informed consent to clinical research. PMID:22942217

  10. Mapping chromatic pathways in the Drosophila visual system.

    PubMed

    Lin, Tzu-Yang; Luo, Jiangnan; Shinomiya, Kazunori; Ting, Chun-Yuan; Lu, Zhiyuan; Meinertzhagen, Ian A; Lee, Chi-Hon

    2016-02-01

    In Drosophila, color vision and wavelength-selective behaviors are mediated by the compound eye's narrow-spectrum photoreceptors R7 and R8 and their downstream medulla projection (Tm) neurons Tm5a, Tm5b, Tm5c, and Tm20 in the second optic neuropil or medulla. These chromatic Tm neurons project axons to a deeper optic neuropil, the lobula, which in insects has been implicated in processing and relaying color information to the central brain. The synaptic targets of the chromatic Tm neurons in the lobula are not known, however. Using a modified GFP reconstitution across synaptic partners (GRASP) method to probe connections between the chromatic Tm neurons and 28 known and novel types of lobula neurons, we identify anatomically the visual projection neurons LT11 and LC14 and the lobula intrinsic neurons Li3 and Li4 as synaptic targets of the chromatic Tm neurons. Single-cell GRASP analyses reveal that Li4 receives synaptic contacts from over 90% of all four types of chromatic Tm neurons, whereas LT11 is postsynaptic to the chromatic Tm neurons, with only modest selectivity and at a lower frequency and density. To visualize synaptic contacts at the ultrastructural level, we develop and apply a "two-tag" double-labeling method to label LT11's dendrites and the mitochondria in Tm5c's presynaptic terminals. Serial electron microscopic reconstruction confirms that LT11 receives direct contacts from Tm5c. This method would be generally applicable to map the connections of large complex neurons in Drosophila and other animals. © 2015 Wiley Periodicals, Inc.

  11. Fatigue Properties of the Ultra-High Strength Steel TM210A

    PubMed Central

    Kang, Xia; Zhao, Gui-ping

    2017-01-01

    This paper presents the results of an experiment to investigate the high cycle fatigue properties of the ultra-high strength steel TM210A. A constant amplitude rotating bending fatigue experiment was performed at room temperature at stress ratio R = −1. In order to evaluate the notch effect, the fatigue experiment was carried out upon two sets of specimens, smooth and notched, respectively. In the experiment, the rotating bending fatigue life was tested using the group method, and the rotating bending fatigue limit was tested using the staircase method at 1 × 107 cycles. A double weighted least square method was then used to fit the stress-life (S–N) curve. The S–N curves of the two sets of specimens were obtained and the morphologies of the fractures of the two sets of specimens were observed with scanning electron microscopy (SEM). The results showed that the fatigue limit of the smooth specimen for rotating bending fatigue was 615 MPa; the ratio of the fatigue limit to tensile strength was 0.29, and the cracks initiated at the surface of the smooth specimen; while the fatigue limit of the notched specimen for rotating bending fatigue was 363 MPa, and the cracks initiated at the edge of the notch. The fatigue notch sensitivity index of the ultra-high strength maraging steel TM210A was 0.69. PMID:28891934

  12. Changes in vegetation spectra with deterioration of leaves under two methods of preservation

    NASA Technical Reports Server (NTRS)

    Labovitz, M. L.; Masuoka, E. J.; Feldmann, S. G.

    1981-01-01

    An experiment to measure changes in leaf spectra under different methods of preservation over time was conducted. The spectral measurements were made by a three band hand held radiometer which simulated three Thematic Mapper (TM) bands: TM3, TM4, and TM5. Daily spectral measurements of white oak leaves under three preservation treatments were made. The spectral readings over three treatments (fresh, bottled, and bagged vegetation) were indistinguishable in bands TM3 and TM5 for up to 4 days after collection. After that time bagged and bottled samples showed significant increases in reflected energy caused by loss of chlorophyll from and dehydration of the vegetation. No significant variation in the reflectance values from TM4 over preservation type for the experimental period was observed.

  13. [Algorithm for estimating chlorophyll-a concentration in case II water body based on bio-optical model].

    PubMed

    Yang, Wei; Chen, Jin; Mausushita, Bunki

    2009-01-01

    In the present study, a novel retrieval method for estimating chlorophyll-a concentration in case II waters based on bio-optical model was proposed and was tested with the data measured in the laboratory. A series of reflectance spectra, with which the concentration of each sample constituent (for example chlorophyll-a, NPSS etc.) was obtained from accurate experiments, were used to calculate the absorption and backscattering coefficients of the constituents of the case II waters. Then non-negative least square method was applied to calculate the concentration of chlorophyll-a and non-phytoplankton suspended sediments (NPSS). Green algae was firstly collected from the Kasumigaura lake in Japan and then cultured in the laboratory. The reflectance spectra of waters with different amounts of phytoplankton and NPSS were measured in the dark room using FieldSpec Pro VNIR (Analytical Spectral Devises Inc. , Boulder, CO, USA). In order to validate whether this method can be applied in multispectral data (for example Landsat TM), the spectra measured in the laboratory were resampled with Landsat TM bands 1, 2, 3 and 4. Different combinations of TM bands were compared to derive the most appropriate wavelength for detecting chlorophyll-a in case II water for green algae. The results indicated that the combination of TM bands 2, 3 and 4 achieved much better accuracy than other combinations, and the estimated concentration of chlorophyll-a was significantly more accurate than empirical methods. It is expected that this method can be directly applied to the real remotely sensed image because it is based on bio-optical model.

  14. Eco-design pilot project in China - Monsoon offer 2 upgrade

    NASA Astrophysics Data System (ADS)

    Thai, Roselyne; Liu, Guoguo

    2017-11-01

    During COP21, Schneider Electric has committed that 100% of our new products would be eco-designed to tackle climate change. Launched in 2015, this initiative ecoDesign WayTM was tested on some pilot projects. This project covers the first ecoDesign WayTM pilot in China on an overvoltage or under voltage protective device used in both residential and industrial sectors, called Monsoon. Under the name ecoDesign WayTM, a method and a process have been deployed. The 3 main ecoDesign WayTM phases are: phase 1 - Marketing & Technique handshake, Phase 2 - ecoDesign WayTM follow-up and Phase 3 - Marketing communication. During the project, EIME from Bureau Veritas CODDE and ecoDesign WayTM scorecard from EVEA consulting are two core tools for eco-design implementation. They are respectively used for life cycle assessment and eco-design performance comparison. Thanks to the approach, compared to previous range, pollution emissions and resource depletion along the whole life cycle of product have decreased (reduction of 55% for energy depletion and 85% for water depletion). Global warming potential has dramatically decreased by 98.4% and air pollution by 33%. Meanwhile, the recycling rate has been improved by 18%, and recycled PA is used. The ecoDesign WayTM scorecard is stored as referent document for any customer request. Moreover, customers can access RoHS certificate, REACh declaration, PEP and EoLI in Check a product, an online environmental data repository, available 24/7.

  15. Supplementation of soft drinks with metallic ions reduces dissolution of bovine enamel

    PubMed Central

    PEREIRA, Heloisa Aparecida Barbosa da Silva; LEITE, Aline de Lima; ITALIANI, Flávia de Moraes; KATO, Melissa Thiemi; PESSAN, Juliano Pelim; BUZALAF, Marília Afonso Rabelo

    2013-01-01

    Objective The aim of this study was to evaluate the effect of the addition of metallic ions to carbonated drinks on their erosive potential. Material and Methods Powdered enamel was added to carbonated beverages (Coca-ColaTM or Sprite ZeroTM and shaken for 30 s. The samples were then immediately centrifuged and the supernatant removed. This procedure was repeated 5 times with the beverages containing Cu2+, Mg2+, Mn2+ or Zn2+ (1.25-60 mmol/L). For Coca-ColaTM, the concentration of each ion that exhibited the highest protection was also evaluated in combination with Fe2+. The phosphate or calcium released were analyzed spectrophotometrically. Data were analyzed using ANOVA and Tukey's test (p<0.05). Results For Coca-ColaTM, the best protective effect was observed for Zn2+ alone (10 mmol/L) or in combination (1 mmol/L) with other ions (12% and 27%, respectively, when compared with the control). Regarding Sprite ZeroTM, the best protective effect was observed for Cu2+ at 15 and 30 mmol/L, which decreased the dissolution by 22-23%. Zn2+ at 2.5 mmol/L also reduced the dissolution of powdered enamel by 8%. Conclusions The results suggest that the combination of metallic ions can be an alternative to reduce the erosive potential of Coca-ColaTM. Regarding Sprite ZeroTM, the addition of Cu2+ seems to be the best alternative. PMID:24037077

  16. Utility, reliability, sensitivity and validity of an online test system designed to monitor changes in cognitive function in clinical trials.

    PubMed

    Wesnes, Keith A; Brooker, Helen; Ballard, Clive; McCambridge, Laura; Stenton, Robert; Corbett, Anne

    2017-12-01

    The advent of long-term remotely conducted clinical trials requires assessments which can be administered online. This paper considers the utility, reliability, sensitivity and validity of an internet-based system for measuring changes in cognitive function which is being used in one such trial. The Platform for Research Online to investigate Genetics and Cognition in Ageing is a 10-year longitudinal and entirely remote study launched in November 2015. The CogTrack TM System is being used to monitor changes in important aspects of cognitive function using tests of attention, information processing and episodic memory. On study entry, the participants performed CogTrack TM up to three times over seven days, and these data are evaluated in this paper. During the first six months of the study, 14 531 individuals aged 50 to 94 years enrolled and performed the CogTrack TM System, 8627 of whom completed three test sessions. On the first administration, 99.4% of the study tasks were successfully completed. Repeated testing showed training/familiarisation effects on four of the ten measures which had largely stabilised by the third test session. The factor structure of the various measures was found to be robust. Evaluation of the influence of age identified clinically relevant declines over the age range of the population on one or more measures from all tasks. The results of these analyses identify CogTrack TM to be a practical and valid method to reliably, sensitively, remotely and repeatedly collect cognitive data from large samples of individuals aged 50 and over. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  17. Analysis of the quality of image data acquired by the LANDSAT-4 Thematic Mapper and Multispectral Scanners

    NASA Technical Reports Server (NTRS)

    Colwell, R. N. (Principal Investigator)

    1984-01-01

    The geometric quality of TM film and digital products is evaluated by making selective photomeasurements and by measuring the coordinates of known features on both the TM products and map products. These paired observations are related using a standard linear least squares regression approach. Using regression equations and coefficients developed from 225 (TM film product) and 20 (TM digital product) control points, map coordinates of test points are predicted. The residual error vectors and analysis of variance (ANOVA) were performed on the east and north residual using nine image segments (blocks) as treatments. Based on the root mean square error of the 223 (TM film product) and 22 (TM digital product) test points, users of TM data expect the planimetric accuracy of mapped points to be within 91 meters and within 117 meters for the film products, and to be within 12 meters and within 14 meters for the digital products.

  18. Text Messaging Improves Participation in Laboratory Testing in Adolescent Liver Transplant Patients.

    PubMed

    McKenzie, Rebecca B; Berquist, William E; Foley, Megan A; Park, K T; Windsheimer, Jered E; Litt, Iris F

    In solid organ transplant patients, non-participation in all aspects of the medical regimen is a prevalent problem associated with adverse consequences particularly in the adolescent and young adult (AYA) age group. This study is the first to evaluate the feasibility, utility and impact of a text messaging (TM) intervention to improve participation in laboratory testing in adolescent liver transplant patients. AYA patients, aged 12 to 21 years, were recruited for a prospective pilot trial evaluating a TM intervention delivered over a 1-year period. The intervention involved automated TM reminders with feedback administered according to a prescribed laboratory testing frequency. Participation rate in laboratory testing after the intervention was compared to the year prior. Patient responses and feedback by text and survey were used to assess feasibility, acceptability and use of the intervention. Forty-two patients were recruited and 33 patients remained enrolled for the study duration. Recipients of the TM intervention demonstrated a significant improvement in participation rate in laboratory testing from 58% to 78% (P<.001). This rate was also significantly higher than in non-intervention controls (P=.003). There was a high acceptability, response rate and a significant correlation with reported versus actual completion of laboratory tests by TM. TM reminders significantly improved participation in laboratory testing in AYA liver transplant patients. The intervention demonstrated feasibility, acceptability, and use with a high proportion of patients who engaged in and perceived a benefit from using this technology.

  19. The effectiveness of digital microscopy as a teaching tool in medical laboratory science curriculum.

    PubMed

    Castillo, Demetra

    2012-01-01

    A fundamental component to the practice of Medical Laboratory Science (MLS) is the microscope. While traditional microscopy (TM) is gold standard, the high cost of maintenance has led to an increased demand for alternative methods, such as digital microscopy (DM). Slides embedded with blood specimens are converted into a digital form that can be run with computer driven software. The aim of this study was to investigate the effectiveness of digital microscopy as a teaching tool in the field of Medical Laboratory Science. Participants reviewed known study slides using both traditional and digital microscopy methods and were assessed using both methods. Participants were randomly divided into two groups. Group 1 performed TM as the primary method and DM as the alternate. Group 2 performed DM as the primary and TM as the alternate. Participants performed differentials with their primary method, were assessed with both methods, and then performed differentials with their alternate method. A detailed assessment rubric was created to determine the accuracy of student responses through comparison of clinical laboratory and instructor results. Student scores were reflected as a percentage correct from these methods. This assessment was done over two different classes. When comparing results between methods for each, independent of the primary method used, results were not statistically different. However, when comparing methods between groups, Group 1 (n = 11) (TM = 73.79% +/- 9.19, DM = 81.43% +/- 8.30; paired t10 = 0.182, p < 0.001) showed a significant difference from Group 2 (n = 14) (TM = 85.64% +/- 5.30, DM = 85.91% +/- 7.62; paired t13 = 3.647, p = 0.860). In the subsequent class, results between both groups (n = 13, n = 16, respectively) did not show any significant difference between groups (Group 1 TM = 86.38% +/- 8.17, Group 1 DM = 88.69% +/- 3.86; paired t12 = 1.253, p = 0.234; Group 2 TM = 86.75% +/- 5.37, Group 2 DM = 86.25% +/- 7.01, paired t15 = 0.280, p = 0.784). The data suggest that DM is comparable to TM. DM could be used as an enhancement model after foundational information was provided using TM.

  20. Comparison of four different methods for detection of biofilm formation by uropathogens.

    PubMed

    Panda, Pragyan Swagatika; Chaudhary, Uma; Dube, Surya K

    2016-01-01

    Urinary tract infection (UTI) is one of the most common infectious diseases encountered in clinical practice. Emerging resistance of the uropathogens to the antimicrobial agents due to biofilm formation is a matter of concern while treating symptomatic UTI. However, studies comparing different methods for detection of biofilm by uropathogens are scarce. To compare four different methods for detection of biofilm formation by uropathogens. Prospective observational study conducted in a tertiary care hospital. Totally 300 isolates from urinary samples were analyzed for biofilm formation by four methods, that is, tissue culture plate (TCP) method, tube method (TM), Congo Red Agar (CRA) method and modified CRA (MCRA) method. Chi-square test was applied when two or more set of variables were compared. P < 0.05 considered as statistically significant. Considering TCP to be a gold standard method for our study we calculated other statistical parameters. The rate of biofilm detection was 45.6%, 39.3% and 11% each by TCP, TM, CRA and MCRA methods, respectively. The difference between TCP and only CRA/MCRA was significant, but not that between TCP and TM. There was no difference in the rate of biofilm detection between CRA and MCRA in other isolates, but MCRA is superior to CRA for detection of the staphylococcal biofilm formation. TCP method is the ideal method for detection of bacterial biofilm formation by uropathogens. MCRA method is superior only to CRA for detection of staphylococcal biofilm formation.

  1. Expression, tissue localization and serodiagnostic potential of Taenia multiceps acidic ribosomal protein P2.

    PubMed

    Huang, Xing; Chen, Lin; Yang, Yingdong; Gu, Xiaobin; Wang, Yu; Lai, Weimin; Peng, Xuerong; Yang, Guangyou

    2015-12-01

    The larval stage of Taenia multiceps, also known as coenurus, is the causative agent of coenurosis, which results in severe health problems in sheep, goats, cattle and other animals that negatively impact on animal husbandry. There is no reliable method to identify coenurus infected goats in the early period of infection. We identified a full-length cDNA that encodes acidic ribosomal protein P2 from the transcriptome of T. multiceps (TmP2). Following cloning, sequencing and structural analyses were performed using bioinformatics tools. Recombinant TmP2 (rTmP2) was prokaryotically expressed and then used to test immunoreactivity and immunogenicity in immunoblotting assays. The native proteins in adult stage and coenurus were located via immunofluorescence assays, while the potential of rTmP2 for indirect ELISA-based serodiagnostics was assessed using native goat sera. In addition, 20 goats were randomly divided into a drug treatment group and a control group. Each goat was orally given mature, viable T. multiceps eggs. The drug treatment group was given 10% praziquantel by intramuscular injection 45 days post-infection (p.i), and all goats were screened for anti-TmP2 antibodies with the indirect ELISA method established here, once a week for 17 weeks p.i. The open reading frame (366 bp) of the target gene encodes a 12.62 kDa protein, which showed high homology to that from Taenia solium (93% identity) and lacked a signal peptide. Immunofluorescence staining showed that TmP2 was highly localized to the parenchymatous zone of both the adult parasite and the coenurus; besides, it was widely distributed in cystic wall of coenurus. Building on good immunogenic properties, rTmP2-based ELISA exhibited a sensitivity of 95.0% (19/20) and a specificity of 96.3% (26/27) in detecting anti-P2 antibodies in the sera of naturally infected goats and sheep. In goats experimentally infected with T. multiceps, anti-TmP2 antibody was detectable in the control group from 3 to 10 weeks and 15 to 17 weeks p.i. In the drug-treated group, the anti-TmP2 antibody dropped below the cut-off value about 2 weeks after treatment with praziquantel and remained below this critical value until the end of the experiment. The indirect ELISA method developed in this study has the potential for detection of T. multiceps infections in hosts.

  2. Practicing more retrieval routes leads to greater memory retention.

    PubMed

    Zheng, Jun; Zhang, Wei; Li, Tongtong; Liu, Zhaomin; Luo, Liang

    2016-09-01

    A wealth of research has shown that retrieval practice plays a significant role in improving memory retention. The current study focused on one simple yet rarely examined question: would repeated retrieval using two different retrieval routes or using the same retrieval route twice lead to greater long-term memory retention? Participants elaborately learned 22 Japanese-Chinese translation word pairs using two different mediators. Half an hour after the initial study phase, the participants completed two retrieval sessions using either one mediator (Tm1Tm1) or two different mediators (Tm1Tm2). On the final test, which was performed 1week after the retrieval practice phase, the participants received only the cue with a request to report the mediator (M1 or M2) followed by the target (Experiment 1) or only the mediator (M1 or M2) with a request to report the target (Experiment 2). The results of Experiment 1 indicated that the participants who practiced under the Tm1Tm2 condition exhibited greater target retention than those who practiced under the Tm1Tm1 condition. This difference in performance was due to the significant disadvantage in mediator retrieval and decoding of the unpracticed mediator under the Tm1Tm1 condition. Although mediators were provided to participants on the final test in Experiment 2, decoding of the unpracticed mediators remained less effective than decoding of the practiced mediators. We conclude that practicing multiple retrieval routes leads to greater memory retention than focusing on a single retrieval route. Thus, increasing retrieval variability during repeated retrieval practice indeed significantly improves long-term retention in a delay test. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. An ELISA using recombinant TmHSP70 for the diagnosis of Taenia multiceps infections in goats.

    PubMed

    Wang, Yu; Nie, Huaming; Gu, Xiaobin; Wang, Tao; Huang, Xing; Chen, Lin; Lai, Weimin; Peng, Xuerong; Yang, Guangyou

    2015-09-15

    Infections with the tapeworm Taenia multiceps are problematic for ruminant farming worldwide. Here we develop a novel and rapid method for serodiagnosis of T. multiceps infections via an indirect ELISA (iELISA) that uses a heat shock protein, namely, TmHSP70. We extracted the total RNA of T. multiceps from the protoscoleces of cysts dissected from the brains of infected goats. Subsequently, we successfully amplified, cloned and expressed the TmHSP70 gene in Escherichia coli BL21 (DE3). Western blot analysis showed that the recombinant protein (∼34 kDa molecular weight) was recognized by the coenurosis positive serum. Given these initial, robust immunogenic properties for recombinant TmHSP protein, we assessed the ELISA-based serodiagnostic potential of this gene. The indirect ELISA was then optimized to 2.70 μg/well dilution for antigen and 1:80 dilution for serum,while the cut-off value is 0.446. We report that our novel TmHSP ELISA detected T. multiceps sera with a sensitivity of 1:10240 and a specificity of 83.3% (5/6). In a preliminary application, this assay correctly confirmed T. multiceps infection in 30 infected goats, consistent with the clinical examination. This study has revealed that our novel iELISA, which uses the rTmHSP protein, provides a rapid test for diagnosing coenurosis. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Evaluation of cytotoxicity and corrosion resistance of orthodontic mini-implants

    PubMed Central

    Alves, Celha Borges Costa; Segurado, Márcio Nunes; Dorta, Miriam Cristina Leandro; Dias, Fátima Ribeiro; Lenza, Maurício Guilherme; Lenza, Marcos Augusto

    2016-01-01

    ABSTRACT Objective: To evaluate and compare in vitro cytotoxicity and corrosion resistance of mini-implants from three different commercial brands used for orthodontic anchorage. Methods: Six mini-implants (Conexão(tm), Neodent(tm) and SIN(tm)) were separately immersed in artificial saliva (pH 6.76) for 30 and 60 days. The cytotoxicity of the corrosion extracts was assessed in L929 cell cultures using the violet crystal and MTT assays, as well as cell morphology under light microscopy. Metal surface characteristics before and after immersion in artificial saliva were assessed by means of scanning electron microscopy (SEM). The samples underwent atomic absorption spectrophotometry to determine the concentrations of aluminum and vanadium ions, constituent elements of the alloy that present potential toxicity. For statistical analysis, one-way ANOVA/Bonferroni tests were used for comparisons among groups with p < 0.05 considered significant. Statistical analysis was carried out with Graph Pad PRISM software Version 4.0. Results: No changes in cell viability or morphology were observed. Mini-implants SEM images revealed smooth surfaces with no obvious traces of corrosion. The extracts assessed by means of atomic absorption spectrophotometry presented concentrations of aluminum and vanadium ions below 1.0 µg/mL and 0.5 µg/mL, respectively. Conclusion: Orthodontic mini-implants manufactured by Conexão(tm), Neodent(tm) and SIN(tm) present high corrosion resistance and are not cytotoxic. PMID:27901227

  5. MRI-based, wireless determination of the transfer function of a linear implant: Introduction of the transfer matrix.

    PubMed

    Tokaya, Janot P; Raaijmakers, Alexander J E; Luijten, Peter R; van den Berg, Cornelis A T

    2018-04-24

    We introduce the transfer matrix (TM) that makes MR-based wireless determination of transfer functions (TFs) possible. TFs are implant specific measures for RF-safety assessment of linear implants. The TF relates an incident tangential electric field on an implant to a scattered electric field at its tip that generally governs local heating. The TM extends this concept and relates an incident tangential electric field to a current distribution in the implant therewith characterizing the RF response along the entire implant. The TM is exploited to measure TFs with MRI without hardware alterations. A model of rightward and leftward propagating attenuated waves undergoing multiple reflections is used to derive an analytical expression for the TM. This allows parameterization of the TM of generic implants, e.g., (partially) insulated single wires, in a homogeneous medium in a few unknowns that simultaneously describe the TF. These unknowns can be determined with MRI making it possible to measure the TM and, therefore, also the TF. The TM is able to predict an induced current due to an incident electric field and can be accurately parameterized with a limited number of unknowns. Using this description the TF is determined accurately (with a Pearson correlation coefficient R ≥ 0.9 between measurements and simulations) from MRI acquisitions. The TM enables measuring of TFs with MRI of the tested generic implant models. The MR-based method does not need hardware alterations and is wireless hence making TF determination in more realistic scenarios conceivable. © 2018 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.

  6. Pneumatic low-coherence interferometry otoscope to quantify tympanic membrane mobility and middle ear pressure.

    PubMed

    Won, Jungeun; Monroy, Guillermo L; Huang, Pin-Chieh; Dsouza, Roshan; Hill, Malcolm C; Novak, Michael A; Porter, Ryan G; Chaney, Eric; Barkalifa, Ronit; Boppart, Stephen A

    2018-02-01

    Pneumatic otoscopy to assess the mobility of the tympanic membrane (TM) is a highly recommended diagnostic method of otitis media (OM), a widespread middle ear infection characterized by the fluid accumulation in the middle ear. Nonetheless, limited depth perception and subjective interpretation of small TM displacements have challenged the appropriate and efficient examination of TM dynamics experienced during OM. In this paper, a pneumatic otoscope integrated with low coherence interferometry (LCI) was adapted with a controlled pressure-generating system to record the pneumatic response of the TM and to estimate middle ear pressure (MEP). Forty-two ears diagnosed as normal (n = 25), with OM (n = 10), or associated with an upper respiratory infection (URI) (n = 7) were imaged with a pneumatic LCI otoscope with an axial, transverse, and temporal resolution of 6 µm, 20 µm, and 1 msec, respectively. The TM displacement under pneumatic pressure transients (a duration of 0.5 sec with an intensity of ± 150 daPa) was measured to compute two metrics (compliance and amplitude ratio). These metrics were correlated with peak acoustic admittance and MEP from tympanometry and statistically compared via Welch's t- test. As a result, the compliance represents pneumatic TM mobility, and the amplitude ratio estimates MEP. The presence of a middle ear effusion (MEE) significantly decreased compliance (p<0.001). The amplitude ratio of the OM group was statistically less than that of the normal group (p<0.01), indicating positive MEP. Unlike tympanometry, pneumatic LCI otoscopy quantifies TM mobility as well as MEP regardless of MEE presence. With combined benefits of pneumatic otoscopy and tympanometry, pneumatic LCI otoscopy may provide new quantitative metrics for understanding TM dynamics and diagnosing OM.

  7. Pneumatic low-coherence interferometry otoscope to quantify tympanic membrane mobility and middle ear pressure

    PubMed Central

    Won, Jungeun; Monroy, Guillermo L.; Huang, Pin-Chieh; Dsouza, Roshan; Hill, Malcolm C.; Novak, Michael A.; Porter, Ryan G.; Chaney, Eric; Barkalifa, Ronit; Boppart, Stephen A.

    2018-01-01

    Pneumatic otoscopy to assess the mobility of the tympanic membrane (TM) is a highly recommended diagnostic method of otitis media (OM), a widespread middle ear infection characterized by the fluid accumulation in the middle ear. Nonetheless, limited depth perception and subjective interpretation of small TM displacements have challenged the appropriate and efficient examination of TM dynamics experienced during OM. In this paper, a pneumatic otoscope integrated with low coherence interferometry (LCI) was adapted with a controlled pressure-generating system to record the pneumatic response of the TM and to estimate middle ear pressure (MEP). Forty-two ears diagnosed as normal (n = 25), with OM (n = 10), or associated with an upper respiratory infection (URI) (n = 7) were imaged with a pneumatic LCI otoscope with an axial, transverse, and temporal resolution of 6 µm, 20 µm, and 1 msec, respectively. The TM displacement under pneumatic pressure transients (a duration of 0.5 sec with an intensity of ± 150 daPa) was measured to compute two metrics (compliance and amplitude ratio). These metrics were correlated with peak acoustic admittance and MEP from tympanometry and statistically compared via Welch’s t-test. As a result, the compliance represents pneumatic TM mobility, and the amplitude ratio estimates MEP. The presence of a middle ear effusion (MEE) significantly decreased compliance (p<0.001). The amplitude ratio of the OM group was statistically less than that of the normal group (p<0.01), indicating positive MEP. Unlike tympanometry, pneumatic LCI otoscopy quantifies TM mobility as well as MEP regardless of MEE presence. With combined benefits of pneumatic otoscopy and tympanometry, pneumatic LCI otoscopy may provide new quantitative metrics for understanding TM dynamics and diagnosing OM. PMID:29552381

  8. Spectroradiometric calibration of the Thematic Mapper and Multispectral Scanner system. [White Sands, New Mexico

    NASA Technical Reports Server (NTRS)

    Palmer, J. M. (Principal Investigator); Slater, P. N.

    1984-01-01

    The newly built Caste spectropolarimeters gave satisfactory performance during tests in the solar radiometer and helicopter modes. A bandwidth normalization technique based on analysis of the moments of the spectral responsivity curves was used to analyze the spectral bands of the MSS and TM subsystems of LANDSAT 4 and 5 satellites. Results include the effective wavelength, the bandpass, the wavelength limits, and the normalized responsivity for each spectral channel. Temperature coefficients for TM PF channel 6 were also derived. The moments normalization method used yields sensor parameters whose derivation is independent of source characteristics (i.e., incident solar spectral irradiance, atmospheric transmittance, or ground reflectance). The errors expected using these parameters are lower than those expected using other normalization methods.

  9. Medical student appraisal: searching on smartphones.

    PubMed

    Khalifian, S; Markman, T; Sampognaro, P; Mitchell, S; Weeks, S; Dattilo, J

    2013-01-01

    The rapidly growing industry for mobile medical applications provides numerous smartphone resources designed for healthcare professionals. However, not all applications are equally useful in addressing the questions of early medical trainees. Three popular, free, mobile healthcare applications were evaluated along with a Google(TM) web search on both Apple(TM) and Android(TM) devices. Six medical students at a large academic hospital evaluated each application for a one-week period while on various clinical rotations. Google(TM) was the most frequently used search method and presented multimedia resources but was inefficient for obtaining clinical management information. Epocrates(TM) Pill ID feature was praised for its clinical utility. Medscape(TM) had the highest satisfaction of search and excelled through interactive educational features. Micromedex(TM) offered both FDA and off-label dosing for drugs. Google(TM) was the preferred search method for questions related to basic disease processes and multimedia resources, but was inadequate for clinical management. Caution should also be exercised when using Google(TM) in front of patients. Medscape(TM) was the most appealing application due to a broad scope of content and educational features relevant to medical trainees. Students should also be cognizant of how mobile technology may be perceived by their evaluators to avoid false impressions.

  10. Radiometric calibration of Landsat Thematic Mapper multispectral images

    USGS Publications Warehouse

    Chavez, P.S.

    1989-01-01

    A main problem encountered in radiometric calibration of satellite image data is correcting for atmospheric effects. Without this correction, an image digital number (DN) cannot be converted to a surface reflectance value. In this paper the accuracy of a calibration procedure, which includes a correction for atmospheric scattering, is tested. Two simple methods, a stand-alone and an in situ sky radiance measurement technique, were used to derive the HAZE DN values for each of the six reflectance Thematic Mapper (TM) bands. The DNs of two Landsat TM images of Phoenix, Arizona were converted to surface reflectances. -from Author

  11. Non-animal methods to predict skin sensitization (I): the Cosmetics Europe database.

    PubMed

    Hoffmann, Sebastian; Kleinstreuer, Nicole; Alépée, Nathalie; Allen, David; Api, Anne Marie; Ashikaga, Takao; Clouet, Elodie; Cluzel, Magalie; Desprez, Bertrand; Gellatly, Nichola; Goebel, Carsten; Kern, Petra S; Klaric, Martina; Kühnl, Jochen; Lalko, Jon F; Martinozzi-Teissier, Silvia; Mewes, Karsten; Miyazawa, Masaaki; Parakhia, Rahul; van Vliet, Erwin; Zang, Qingda; Petersohn, Dirk

    2018-05-01

    Cosmetics Europe, the European Trade Association for the cosmetics and personal care industry, is conducting a multi-phase program to develop regulatory accepted, animal-free testing strategies enabling the cosmetics industry to conduct safety assessments. Based on a systematic evaluation of test methods for skin sensitization, five non-animal test methods (DPRA (Direct Peptide Reactivity Assay), KeratinoSens TM , h-CLAT (human cell line activation test), U-SENS TM , SENS-IS) were selected for inclusion in a comprehensive database of 128 substances. Existing data were compiled and completed with newly generated data, the latter amounting to one-third of all data. The database was complemented with human and local lymph node assay (LLNA) reference data, physicochemical properties and use categories, and thoroughly curated. Focused on the availability of human data, the substance selection resulted nevertheless resulted in a high diversity of chemistries in terms of physico-chemical property ranges and use categories. Predictivities of skin sensitization potential and potency, where applicable, were calculated for the LLNA as compared to human data and for the individual test methods compared to both human and LLNA reference data. In addition, various aspects of applicability of the test methods were analyzed. Due to its high level of curation, comprehensiveness, and completeness, we propose our database as a point of reference for the evaluation and development of testing strategies, as done for example in the associated work of Kleinstreuer et al. We encourage the community to use it to meet the challenge of conducting skin sensitization safety assessment without generating new animal data.

  12. The statistics of identifying differentially expressed genes in Expresso and TM4: a comparison

    PubMed Central

    Sioson, Allan A; Mane, Shrinivasrao P; Li, Pinghua; Sha, Wei; Heath, Lenwood S; Bohnert, Hans J; Grene, Ruth

    2006-01-01

    Background Analysis of DNA microarray data takes as input spot intensity measurements from scanner software and returns differential expression of genes between two conditions, together with a statistical significance assessment. This process typically consists of two steps: data normalization and identification of differentially expressed genes through statistical analysis. The Expresso microarray experiment management system implements these steps with a two-stage, log-linear ANOVA mixed model technique, tailored to individual experimental designs. The complement of tools in TM4, on the other hand, is based on a number of preset design choices that limit its flexibility. In the TM4 microarray analysis suite, normalization, filter, and analysis methods form an analysis pipeline. TM4 computes integrated intensity values (IIV) from the average intensities and spot pixel counts returned by the scanner software as input to its normalization steps. By contrast, Expresso can use either IIV data or median intensity values (MIV). Here, we compare Expresso and TM4 analysis of two experiments and assess the results against qRT-PCR data. Results The Expresso analysis using MIV data consistently identifies more genes as differentially expressed, when compared to Expresso analysis with IIV data. The typical TM4 normalization and filtering pipeline corrects systematic intensity-specific bias on a per microarray basis. Subsequent statistical analysis with Expresso or a TM4 t-test can effectively identify differentially expressed genes. The best agreement with qRT-PCR data is obtained through the use of Expresso analysis and MIV data. Conclusion The results of this research are of practical value to biologists who analyze microarray data sets. The TM4 normalization and filtering pipeline corrects microarray-specific systematic bias and complements the normalization stage in Expresso analysis. The results of Expresso using MIV data have the best agreement with qRT-PCR results. In one experiment, MIV is a better choice than IIV as input to data normalization and statistical analysis methods, as it yields as greater number of statistically significant differentially expressed genes; TM4 does not support the choice of MIV input data. Overall, the more flexible and extensive statistical models of Expresso achieve more accurate analytical results, when judged by the yardstick of qRT-PCR data, in the context of an experimental design of modest complexity. PMID:16626497

  13. Goddard Space Flight Center specification for Helical-Scan 8-millimeter (mm) magnetic digital data tape cartridge

    NASA Technical Reports Server (NTRS)

    Perry, Jimmy L.

    1992-01-01

    The same kind of standard and controls are established that are currently in use for the procurement of new analog, digital, and IBM/IBM compatible 3480 tape cartridges, and 1 in wide channel video magnetic tapes. The Magnetic Tape Certification Facility (MTCF) maintains a Qualified Products List (QPL) for the procurement of new magnetic media and uses the following specifications for the QPL and Acceptance Tests: (1) NASA TM-79724 is used for the QPL and Acceptance Testing of new analog magnetic tapes; (2) NASA TM-80599 is used for the QPL and Acceptance Testing of new digital magnetic tapes; (3) NASA TM-100702 is used for the QPL and Acceptance Testing of new IBM/IBM compatible 3840 magnetic tape cartridges; and (4) NASA TM-100712 is used for the QPL and Acceptance Testing of new 1 in wide channel video magnetic tapes. This document will be used for the QPL and Acceptance Testing of new Helical Scan 8 mm digital data tape cartridges.

  14. Research on the Calculation Method of Optical Path Difference of the Shanghai Tian Ma Telescope

    NASA Astrophysics Data System (ADS)

    Dong, J.; Fu, L.; Jiang, Y. B.; Liu, Q. H.; Gou, W.; Yan, F.

    2016-03-01

    Based on the Shanghai Tian Ma Telescope (TM), an optical path difference calculation method of the shaped Cassegrain antenna is presented in the paper. Firstly, the mathematical model of the TM optics is established based on the antenna reciprocity theorem. Secondly, the TM sub-reflector and main reflector are fitted by the Non-Uniform Rational B-Splines (NURBS). Finally, the method of optical path difference calculation is implemented, and the expanding application of the Ruze optical path difference formulas in the TM is researched. The method can be used to calculate the optical path difference distributions across the aperture field of the TM due to misalignment like the axial and lateral displacements of the feed and sub-reflector, or the tilt of the sub-reflector. When the misalignment quantity is small, the expanding Ruze optical path difference formulas can be used to calculate the optical path difference quickly. The paper supports the real-time measurement and adjustment of the TM structure. The research has universality, and can provide reference for the optical path difference calculation of other radio telescopes with shaped surfaces.

  15. Simulation-based evaluation of the resolution and quantitative accuracy of temperature-modulated fluorescence tomography

    PubMed Central

    Lin, Yuting; Nouizi, Farouk; Kwong, Tiffany C.; Gulsen, Gultekin

    2016-01-01

    Conventional fluorescence tomography (FT) can recover the distribution of fluorescent agents within a highly scattering medium. However, poor spatial resolution remains its foremost limitation. Previously, we introduced a new fluorescence imaging technique termed “temperature-modulated fluorescence tomography” (TM-FT), which provides high-resolution images of fluorophore distribution. TM-FT is a multimodality technique that combines fluorescence imaging with focused ultrasound to locate thermo-sensitive fluorescence probes using a priori spatial information to drastically improve the resolution of conventional FT. In this paper, we present an extensive simulation study to evaluate the performance of the TM-FT technique on complex phantoms with multiple fluorescent targets of various sizes located at different depths. In addition, the performance of the TM-FT is tested in the presence of background fluorescence. The results obtained using our new method are systematically compared with those obtained with the conventional FT. Overall, TM-FT provides higher resolution and superior quantitative accuracy, making it an ideal candidate for in vivo preclinical and clinical imaging. For example, a 4 mm diameter inclusion positioned in the middle of a synthetic slab geometry phantom (D:40 mm × W :100 mm) is recovered as an elongated object in the conventional FT (x = 4.5 mm; y = 10.4 mm), while TM-FT recovers it successfully in both directions (x = 3.8 mm; y = 4.6 mm). As a result, the quantitative accuracy of the TM-FT is superior because it recovers the concentration of the agent with a 22% error, which is in contrast with the 83% error of the conventional FT. PMID:26368884

  16. Flight Testing of a Low Cost De-Orbiting Device for Small Satellites

    NASA Technical Reports Server (NTRS)

    Turse, Dana; Keller, Phil; Taylor, Robert; Reavis, Mark; Tupper, Mike; Koehler, Chris

    2014-01-01

    Use of small and very small spacecraft is rapidly becoming more common. Methods to intentionally deorbit these spacecraft at the end of useful satellite life are required. A family of mass efficient Roll-Out De- Orbiting devices (RODEO"TM") was developed by Composite Technology Development, Inc. (CTD). RODEO"TM" consists of lightweight film attached to a simple, ultra-lightweight, roll-out composite boom structure. This system is rolled to stow within a lightweight launch canister, allowing easy integration to the small satellite bus. The device is released at the end of useful lifetime and the RODEO"TM" composite boom unrolls the drag sail in a matter of seconds. This dramatically increases the deployed surface area, resulting in the higher aerodynamic drag that significantly reduces the time until reentry. A RODEO"TM" flight demonstration was recently conducted as part of the Colorado Space Grant Consortium's (COSGC) RocketSat-8 program, a program to provide students hands-on experience in developing experiments for space flight. The experiment was ultimately a success and RODEO (trademark) is now ready for future CubeSat missions.

  17. ExpoCast: Exposure Science for Prioritization and Toxicity Testing

    EPA Science Inventory

    The US EPA is completing the Phase I pilot for a chemical prioritization research program, called ToxCastTM. Here EPA is developing methods for using computational chemistry, high-throughput screening, and toxicogenomic technologies to predict potential toxicity and prioritize l...

  18. EVALUATION OF IMMUNOASSAY METHODS FOR DETERMINATION OF 3,5,6-TRICHLORO-2-PYRIDINOL IN MULTIPLE SAMPLE MEDIA

    EPA Science Inventory

    Two enzyme-linked immunosorbent assay (ELISA) methods were evaluated for the determination of 3,5,6-trichloro-2-pyridinol (3,5,6-TCP) in multiple sample media (dust, soil, food, and urine). The dust and soil samples were analyzed by the RaPID (TM) commercial immunoassay testing ...

  19. Digital holographic measurements of shape and 3D sound-induced displacements of Tympanic Membrane

    PubMed Central

    Lu, Weina; Dobrev, Ivo; Cheng, Jeffrey Tao; Furlong, Cosme; Rosowski, John J

    2014-01-01

    Acoustically-induced vibrations of the Tympanic Membrane (TM) play a primary role in the hearing process, in that these motions are the initial mechanical response of the ear to airborne sound. Characterization of the shape and 3D displacement patterns of the TM is a crucial step to a better understanding of the complicated mechanics of sound reception by the ear. In this paper, shape and sound-induced 3D displacements of the TM in cadaveric chinchillas are measured by a lensless Dual-Wavelength Digital Holography system (DWDHS). The DWDHS consists of Laser Delivery (LD), Optical Head (OH), and Computing Platform (CP) subsystems. Shape measurements are performed in double-exposure mode and with the use of two wavelengths of a tunable laser while nanometer-scale displacements are measured along a single sensitivity direction and with a constant wavelength. In order to extract the three principal components of displacement in full-field-of-view, and taking into consideration the anatomical dimensions of the TM, we combine principles of thin-shell theory together with both, displacement measurements along the single sensitivity vector and TM surface shape. To computationally test this approach, Finite Element Methods (FEM) are applied to the study of artificial geometries. PMID:24790255

  20. Digital holographic measurements of shape and three-dimensional sound-induced displacements of tympanic membrane

    NASA Astrophysics Data System (ADS)

    Khaleghi, Morteza; Lu, Weina; Dobrev, Ivo; Cheng, Jeffrey Tao; Furlong, Cosme; Rosowski, John J.

    2013-10-01

    Acoustically induced vibrations of the tympanic membrane (TM) play a primary role in the hearing process, in that these motions are the initial mechanical response of the ear to airborne sound. Characterization of the shape and three-dimensional (3-D) displacement patterns of the TM is a crucial step to a better understanding of the complicated mechanics of sound reception by the ear. Sound-induced 3-D displacements of the TM are estimated from shape and one-dimensional displacements measured in cadaveric chinchillas using a lensless dual-wavelength digital holography system (DWDHS). The DWDHS consists of laser delivery, optical head, and computing platform subsystems. Shape measurements are performed in double-exposure mode with the use of two wavelengths of a tunable laser, while nanometer-scale displacements are measured along a single sensitivity direction with a constant wavelength. Taking into consideration the geometrical and dimensional constrains imposed by the anatomy of the TM, we combine principles of thin-shell theory together with displacement measurements along a single sensitivity vector and TM surface shape to extract the three principal components of displacement in the full-field-of-view. We test, validate, and identify limitations of this approach via the application of finite element method to artificial geometries.

  1. Assessing the density functional theory-based multireference configuration interaction (DFT/MRCI) method for transition metal complexes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Escudero, Daniel, E-mail: escudero@kofo.mpg.de, E-mail: thiel@kofo.mpg.de; Thiel, Walter, E-mail: escudero@kofo.mpg.de, E-mail: thiel@kofo.mpg.de

    2014-05-21

    We report an assessment of the performance of density functional theory-based multireference configuration interaction (DFT/MRCI) calculations for a set of 3d- and 4d-transition metal (TM) complexes. The DFT/MRCI results are compared to published reference data from reliable high-level multi-configurational ab initio studies. The assessment covers the relative energies of different ground-state minima of the highly correlated CrF{sub 6} complex, the singlet and triplet electronically excited states of seven typical TM complexes (MnO{sub 4}{sup −}, Cr(CO){sub 6}, [Fe(CN){sub 6}]{sup 4−}, four larger Fe and Ru complexes), and the corresponding electronic spectra (vertical excitation energies and oscillator strengths). It includes comparisons withmore » results from different flavors of time-dependent DFT (TD-DFT) calculations using pure, hybrid, and long-range corrected functionals. The DFT/MRCI method is found to be superior to the tested TD-DFT approaches and is thus recommended for exploring the excited-state properties of TM complexes.« less

  2. A study of the development of the Korean version of PedsQL(TM) 3.0 cerebral palsy module and reliability and validity.

    PubMed

    Yun, Young-Ju; Shin, Yong-Beom; Kim, Soo-Yeon; Shin, Myung-Jun; Kim, Ra-Jin; Oh, Tae-Young

    2016-07-01

    [Purpose] The purpose of this study was to develop the Korean version of the PedsQL(TM) 3.0 Cerebral Palsy Module to evaluate the health-related quality of life of children with cerebral palsy and to test the reliability and validity. [Subjects and Methods] The study included 108 caregivers of children with cerebral palsy aged 2 to 4 years and 72 caregivers of children aged 5 to 7 years, who visited multiple sites between February and August 2015. The Translation Commission performed the first translation with the approval of the Mapi Research Trust Company to create a Korean-version of the PedsQL(TM). Afterwards, back-translation was performed by one translator specializing in health and medical treatment who was a native English-speaker fluent in Korean, and one native Korean-speaker fluent in English. The consistency of each question was confirmed and a translation-integrated version was created. Test components were explained to caregivers during a one-on-one interview; caregivers then completed the PedsQL(TM) questionnaire and a Pediatric Evaluation Disability Inventory (PEDI) questionnaire. Subjects contributing to test-retest measures were asked to repeat the PedsQL questionnaire one week later and return it by mail. To assess data quality for the survey question results, non-response rate, ceiling effect, and floor effect were analyzed. Test-retest reliability and internal consistency reliability were assessed. For test-retest reliability, an intraclass correlation coefficient (ICC) was calculated, and for internal consistency reliability, Cronbach's alpha was used. To test criterion-related validity, Pearson's correlation coefficient was used. [Results] The content validity of the PedsQL 3.0 Cerebral Palsy Module was high for both age groups, and demonstrated significant internal consistency (>0.7) in all areas. For test-retest reliability, both groups demonstrated a significant ICC (>0.61). Correlation with the PEDI was statistically significant in all areas except pain and hurt. [Conclusion] The Korean version of the PedsQL(TM) 3.0 Cerebral Palsy Module was found to be reliable and valid, and is expected to contribute greatly to the evaluation of the quality of life of children with cerebral palsy.

  3. LANDSAT-4 image data quality analysis for energy related applications. [nuclear power plant sites

    NASA Technical Reports Server (NTRS)

    Wukelic, G. E. (Principal Investigator)

    1983-01-01

    No useable LANDSAT 4 TM data were obtained for the Hanford site in the Columbia Plateau region, but TM simulator data for a Virginia Electric Company nuclear power plant was used to test image processing algorithms. Principal component analyses of this data set clearly indicated that thermal plumes in surface waters used for reactor cooling would be discrenible. Image processing and analysis programs were successfully testing using the 7 band Arkansas test scene and preliminary analysis of TM data for the Savanah River Plant shows that current interactive, image enhancement, analysis and integration techniques can be effectively used for LANDSAT 4 data. Thermal band data appear adequate for gross estimates of thermal changes occurring near operating nuclear facilities especially in surface water bodies being used for reactor cooling purposes. Additional image processing software was written and tested which provides for more rapid and effective analysis of the 7 band TM data.

  4. Evaluation of penicillin G residues by kidney inhibition swab tests in sow body fluids and tissues following intramuscular injection

    USDA-ARS?s Scientific Manuscript database

    In 2011, the USDA-Food Safety and Inspection Service (FSIS) changed the method used for screening swine tissues for antimicrobial residues to the Kidney Inhibition Swab (KIS(TM)) from the Fast Antimicrobial Screen Test. A high dose of penicillin G procaine relative to a label dose is commonly used ...

  5. AN ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) OF EIGHT RAPID TOXICITY TESTING SYSTEMS: STRATEGIC DIAGNOSTICS INC'S DELTATOX (R) AND MICTOTOX (R), SEVERN TRENT SERVICES ECLOX, HACH COMPANY TOXTRAK INTERLAB SUPPLY, LTD. POLYTOX (TM), CHECKLLIGHT, LTD TOXSCREEN, AQUA SURVEY, INC. IQ TOXICITY TEST (TM), HIDEX OY BIOTOX (TM)

    EPA Science Inventory

    The Environmental Technology Verification (ETV) Program, beginning as an initiative of the U.S. Environmental Protection Agency (EPA) in 1995, verifies the performance of commercially available, innovative technologies that can be used to measure environmental quality. The ETV p...

  6. Predicting protein thermal stability changes upon point mutations using statistical potentials: Introducing HoTMuSiC.

    PubMed

    Pucci, Fabrizio; Bourgeas, Raphaël; Rooman, Marianne

    2016-03-18

    The accurate prediction of the impact of an amino acid substitution on the thermal stability of a protein is a central issue in protein science, and is of key relevance for the rational optimization of various bioprocesses that use enzymes in unusual conditions. Here we present one of the first computational tools to predict the change in melting temperature ΔTm upon point mutations, given the protein structure and, when available, the melting temperature Tm of the wild-type protein. The key ingredients of our model structure are standard and temperature-dependent statistical potentials, which are combined with the help of an artificial neural network. The model structure was chosen on the basis of a detailed thermodynamic analysis of the system. The parameters of the model were identified on a set of more than 1,600 mutations with experimentally measured ΔTm. The performance of our method was tested using a strict 5-fold cross-validation procedure, and was found to be significantly superior to that of competing methods. We obtained a root mean square deviation between predicted and experimental ΔTm values of 4.2 °C that reduces to 2.9 °C when ten percent outliers are removed. A webserver-based tool is freely available for non-commercial use at soft.dezyme.com.

  7. A 1-h time interval between a meal containing iron and consumption of tea attenuates the inhibitory effects on iron absorption: a controlled trial in a cohort of healthy UK women using a stable iron isotope.

    PubMed

    Ahmad Fuzi, Salma F; Koller, Dagmar; Bruggraber, Sylvaine; Pereira, Dora Ia; Dainty, Jack R; Mushtaq, Sohail

    2017-12-01

    Background: Tea has been shown to be a potent inhibitor of nonheme iron absorption, but it remains unclear whether the timing of tea consumption relative to a meal influences iron bioavailability. Objective: The aim of the study was to investigate the effect of a 1-h time interval of tea consumption on nonheme iron absorption in an iron-containing meal in a cohort of iron-replete, nonanemic female subjects with the use of a stable isotope ( 57 Fe). Design: Twelve women (mean ± SD age: 24.8 ± 6.9 y) were administered a standardized porridge meal extrinsically labeled with 4 mg 57 Fe as FeSO 4 on 3 separate occasions, with a 14-d time interval between each test meal (TM). The TM was administered with water (TM-1), with tea administered simultaneously (TM-2), and with tea administered 1 h postmeal (TM-3). Fasted venous blood samples were collected for iron isotopic analysis and measurement of iron status biomarkers. Fractional iron absorption was estimated by the erythrocyte iron incorporation method. Results: Iron absorption was 5.7% ± 8.5% (TM-1), 3.6% ± 4.2% (TM-2), and 5.7% ± 5.4% (TM-3). Mean fractional iron absorption was found to be significantly higher (2.2%) when tea was administered 1 h postmeal (TM-3) than when tea was administered simultaneously with the meal (TM-2) ( P = 0.046). An ∼50% reduction in the inhibitory effect of tea (relative to water) was observed, from 37.2% (TM-2) to 18.1% (TM-3). Conclusions: This study shows that tea consumed simultaneously with an iron-containing porridge meal leads to decreased nonheme iron absorption and that a 1-h time interval between a meal and tea consumption attenuates the inhibitory effect, resulting in increased nonheme iron absorption. These findings are not only important in relation to the management of iron deficiency but should also inform dietary advice, especially that given to those at risk of deficiency. This trial was registered at clinicaltrials.gov as NCT02365103. © 2017 American Society for Nutrition.

  8. Normative wideband reflectance, equivalent admittance at the tympanic membrane, and acoustic stapedius reflex threshold in adults

    PubMed Central

    Feeney, M. Patrick; Keefe, Douglas H.; Hunter, Lisa L.; Fitzpatrick, Denis F.; Garinis, Angela C.; Putterman, Daniel B.; McMillan, Garnett P.

    2016-01-01

    Objectives Wideband acoustic immittance (WAI) measures such as pressure reflectance, parameterized by absorbance and group delay, equivalent admittance at the tympanic membrane (TM), and acoustic stapedius reflex threshold (ASRT) describe middle-ear function across a wide frequency range, compared to traditional tests employing a single frequency. The objective of this study was to obtain normative data using these tests for a group of normal hearing adults and investigate test-retest reliability using a longitudinal design. Design A longitudinal prospective design was used to obtain normative test and retest data on clinical and WAI measures. Subjects were 13 males and 20 females (mean age = 25 y). Inclusion criteria included normal audiometry and clinical immittance. Subjects were tested on two separate visits approximately one month apart. Reflectance and equivalent admittance at the TM were measured from 0.25 to 8.0 kHz under three conditions: at ambient pressure in the ear canal and with pressure sweeps from positive to negative pressure (downswept) and negative to positive pressure (upswept). Equivalent admittance at the TM was calculated using admittance measurements at the probe tip which were adjusted using a model of sound transmission in the ear canal and acoustic estimates of ear-canal area and length. Wideband ASRTs were measured at tympanometric peak pressure (TPP) derived from the average TPP of downswept and upswept tympanograms. Descriptive statistics were obtained for all WAI responses, and wideband and clinical ASRTs were compared. Results Mean absorbance at ambient pressure and TPP demonstrated a broad band-pass pattern typical of previous studies. Test-retest differences were lower for absorbance at TPP for the downswept method compared to ambient pressure at frequencies between 1.0 and 1.26 kHz. Mean tympanometric peak-to-tail differences for absorbance were greatest around 1.0 to 2.0 kHz and similar for positive and negative tails. Mean group delay at ambient pressure and at TPP were greatest between 0.32 and 0.6 kHz at 200 to 300 μs, reduced at frequencies between 0.8 and 1.5 kHz, and increased above 1.5 kHz to around 150 μs. Mean equivalent admittance at the TM had a lower level for the ambient method than at TPP for both sweep directions below 1.2 kHz, but the difference between methods was only statistically significant for the comparison between the ambient method and TPP for the upswept tympanogram. Mean equivalent admittance phase was positive at all frequencies. Test-retest reliability of the equivalent admittance level ranged from 1 to 3 dB at frequencies below 1.0 kHz, but increased to 8 to 9 dB at higher frequencies. The mean wideband ASRT for an ipsilateral broadband noise activator was 12 dB lower than the clinical ASRT, but had poorer reliability. Conclusions Normative data for the WAI test battery revealed minor differences for results at ambient pressure compared to tympanometric methods at TPP for reflectance, group delay, and equivalent admittance level at the TM for subjects with middle-ear pressure within ±100 daPa. Test-retest reliability was better for absorbance at TPP for the downswept tympanogram compared to ambient pressure at frequencies around 1.0 kHz. Large peak-to-tail differences in absorbance combined with good reliability at frequencies between about 0.7 and 3.0 kHz suggest that this may be a sensitive frequency range for interpreting absorbance at TPP. The mean wideband ipsilateral ASRT was lower than the clinical ASRT, consistent with previous studies. Results are promising for the use of a wideband test battery to evaluate middle-ear function. PMID:28045835

  9. Finishing of display glass for mobile electronics using 3M Trizact diamond tile abrasive pads

    NASA Astrophysics Data System (ADS)

    Zheng, Lianbin; Fletcher, Tim; Na, Tee Koon; Sventek, Bruce; Romero, Vince; Lugg, Paul S.; Kim, Don

    2010-10-01

    This paper will describe a new method being used during the finishing of glass displays for mobile electronics including mobile hand held devices and notebook computers. The new method consists of using 3M TrizactTM Diamond Tile Abrasive Pads. TrizactTM Diamond Tile is a structured fixed abrasive grinding technology developed by 3M Company. The TrizactTM Diamond Tile structured abrasive pad consists of an organic (polymeric binder) - inorganic (abrasive mineral, i.e., diamond) composite that is used with a water-based coolant. TrizactTM Diamond Tile technology can be applied in both double and single side grinding applications. A unique advantage of TrizactTM Diamond Tile technology is the combination of high stock removal and low sub-surface damage. Grinding results will be presented for both 9 micron and 20 micron grades of TrizactTM Diamond Tile abrasive pads used to finish several common display glasses including Corning GorillaTM glass and Soda Lime glass.

  10. A healing method of tympanic membrane perforations using three-dimensional porous chitosan scaffolds.

    PubMed

    Kim, Jangho; Kim, Seung Won; Choi, Seong Jun; Lim, Ki Taek; Lee, Jong Bin; Seonwoo, Hoon; Choung, Pill-Hoon; Park, Keehyun; Cho, Chong-Su; Choung, Yun-Hoon; Chung, Jong Hoon

    2011-11-01

    Both surgical tympanoplasty and paper patch grafts are frequently procedured to heal tympanic membrane (TM) perforation or chronic otitis media, despite their many disadvantages. In this study, we report a new healing method of TM perforation by using three-dimensional (3D) porous chitosan scaffolds (3D chitosan scaffolds) as an alternative method to surgical treatment or paper patch graft. Various 3D chitosan scaffolds were prepared; and the structural characteristics, mechanical property, in vitro biocompatibility, and healing effects of the 3D chitosan scaffolds as an artificial TM in in vivo animal studies were investigated. A 3D chitosan scaffold of 5 wt.% chitosan concentration showed good proliferation of TM cells in an in vitro study, as well as suitable structural characteristics and mechanical property, as compared with either 1% or 3% chitosan. In in vivo animal studies, 3D chitosan scaffold were able to migrate through the pores and surfaces of TM cells, thus leading to more effective TM regeneration than paper patch technique. Histological observations demonstrated that the regenerated TM with the 3D chitosan scaffold consisted of three (epidermal, connective tissue, and mucosal) layers and were thicker than normal TMs. The 3D chitosan scaffold technique may be an optimal healing method used in lieu of surgical tympanoplasty in certain cases to heal perforated TMs.

  11. ∼2 μm fluorescence radiative dynamics and energy transfer between Er{sup 3+} and Tm{sup 3+} ions in silicate glass

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Ming; Liu, Xueqiang; Graduate School of Chinese Academy of Sciences, Beijing 100039

    2014-03-01

    Graphical abstract: - Highlights: • A Er{sup 3+}/Tm{sup 3+} co-doped silicate glass with good thermal stability (k{sub gl} = 0.402 for STE glass) is prepared. • Efficient ∼2 μm emission is observed under 808 nm and 980 nm laser excitation. • The glass structure and spectroscopic properties are confirmed by optical absorption, IR transmission, Raman and fluorescence studies. • The content of OH groups deceases efficiently after fluorine ions are introduced. • The energy transfer coefficient from Er{sup 3+} to Tm{sup 3+} in STFE glass is 13.39 × 10{sup −40} cm{sup 6}/s. - Abstract: A Er{sup 3+}/Tm{sup 3+} co-doped silicatemore » glass with good thermal stability is prepared by melt-quenching method. An efficient emission of ∼2 μm is observed under different selective laser excitations. The optical absorption and transmission spectra, Raman spectra, and emission spectra are tested to characterize ∼2 μm emission properties of Er{sup 3+}/Tm{sup 3+} co-doped silicate glasses and a reasonable energy transfer mechanism of ∼2 μm emission between Er{sup 3+} and Tm{sup 3+} ions is proposed. Based on the optical absorption spectra, the Judd–Ofelt parameters and radiative properties were calculated. Intense ∼2 μm emission is obtained from Er{sup 3+}/Tm{sup 3+} co-doped silicate glasses due to the efficient energy transfer from Er{sup 3+} to Tm{sup 3+} ions. The energy transfer coefficient from Er{sup 3+} to Tm{sup 3+} ions can reach as high as 13.39 × 10{sup −40} cm{sup 6}/s. In addition, the population of the OH groups is decreased and the ∼2 μm emission is effectively enhanced with fluoride introduction. The emission property, together with good thermal property, indicates that Er{sup 3+}/Tm{sup 3+} co-doped silicate glass is a potential kind of laser glass for efficient ∼2 μm laser.« less

  12. Stress-Rupture of New Tyranno Si-C-O-Zr Fiber Reinforced Minicomposites

    NASA Technical Reports Server (NTRS)

    Morscher, Gregory N.

    1999-01-01

    Minicomposites consisting of two varieties of Zr containing SiC-based fibers from Ube (Tyranno) with BN interphases and CVI SiC matrices were studied. The two fiber-types were the ZMI and ZE fiber-types that contain approximately 8 and 2% oxygen, respectively. The minicomposites were precracked and tested under constant load testing at temperatures ranging from 700 to 1200 C. The data were then compared to the rupture behavior of Hi- Nicalon (TM) fiber reinforced minicomposites tested under identical conditions. It was found that the Ube fiber-types had stress rupture life equivalent to Hi- Nicalon (TM) over the entire temperature range. A potential benefit of the ZMI fiber-type is that it offers rupture properties almost as good as Hi-Nicalon (TM) at the cost of ceramic grade Nicalon (TM).

  13. Method of quantifying the loss of acidification activity of lactic acid starters during freezing and frozen storage.

    PubMed

    Fonseca, F; Béal, C; Corrieu, G

    2000-02-01

    We have developed a method to quantify the resistance to freezing and frozen storage of lactic acid starters, based on measuring the time necessary to reach the maximum acidification rate in milk (tm) using the Cinac system. Depending on the operating conditions, tm increased during the freezing step and storage. The loss of acidification activity during freezing was quantified by the difference (delta tm) between the tm values of the concentrated cell suspension before and after freezing. During storage at -20 degrees C, linear relationships between tm and the storage time were established. Their slope, k, allowed the quantitation of the decrease in acidification activity during 9-14 weeks of frozen storage. The method was applied to determine the resistance to freezing and frozen storage of four strains of lactic acid bacteria and to quantify the cryoprotective effect of glycerol.

  14. Simulation-based evaluation of the resolution and quantitative accuracy of temperature-modulated fluorescence tomography.

    PubMed

    Lin, Yuting; Nouizi, Farouk; Kwong, Tiffany C; Gulsen, Gultekin

    2015-09-01

    Conventional fluorescence tomography (FT) can recover the distribution of fluorescent agents within a highly scattering medium. However, poor spatial resolution remains its foremost limitation. Previously, we introduced a new fluorescence imaging technique termed "temperature-modulated fluorescence tomography" (TM-FT), which provides high-resolution images of fluorophore distribution. TM-FT is a multimodality technique that combines fluorescence imaging with focused ultrasound to locate thermo-sensitive fluorescence probes using a priori spatial information to drastically improve the resolution of conventional FT. In this paper, we present an extensive simulation study to evaluate the performance of the TM-FT technique on complex phantoms with multiple fluorescent targets of various sizes located at different depths. In addition, the performance of the TM-FT is tested in the presence of background fluorescence. The results obtained using our new method are systematically compared with those obtained with the conventional FT. Overall, TM-FT provides higher resolution and superior quantitative accuracy, making it an ideal candidate for in vivo preclinical and clinical imaging. For example, a 4 mm diameter inclusion positioned in the middle of a synthetic slab geometry phantom (D:40  mm×W:100  mm) is recovered as an elongated object in the conventional FT (x=4.5  mm; y=10.4  mm), while TM-FT recovers it successfully in both directions (x=3.8  mm; y=4.6  mm). As a result, the quantitative accuracy of the TM-FT is superior because it recovers the concentration of the agent with a 22% error, which is in contrast with the 83% error of the conventional FT.

  15. Tm:GGAG crystal for 2μm tunable diode-pumped laser

    NASA Astrophysics Data System (ADS)

    Šulc, Jan; Boháček, Pavel; Němec, Michal; Fibrich, Martin; Jelínková, Helena; Trunda, Bohumil; Havlák, Lubomír.; Jurek, Karel; Nikl, Martin

    2016-04-01

    The spectroscopy properties and wavelength tunability of diode pumped laser based on Tm-doped mixed gadolinium-gallium-aluminium garnet Gd3(GaxAl1-x)5O12 (Tm:GGAG) single crystal were investigated for the first time. The crystal was grown by Czochralski method in a slightly oxidative atmosphere using an iridium crucible. The tested Tm:GGAG sample was cut from the grown crystal boule perpendicularly to growth direction (c-axis). The composition of sample was determined using electron microprobe X-ray elemental analysis. For spectroscopy and laser experiments 3.5mm thick plane-parallel face-polished plate (without AR coatings) with composition Gd2.76Tm0.0736Ga2.67Al2.50O12 (2.67 at.% Tm/Gd) was used. A fiber (core diameter 400 μm, NA= 0.22) coupled laser diode (emission wavelength 786 nm) was used for longitudinal Tm:GGAG pumping. The laser diode was operating in the pulsed regime (10 ms pulse length, 10 Hz repetition rate, maximum power amplitude 18 W). The 145mm long semi-hemispherical laser resonator consisted of a flat pumping mirror (HR @ 1.8- 2.10 μm, HT @ 0.78 μm) and curved (r = 150mm) output coupler with a reflectivity of » 97% @ 1.8- 2.10 µm. The maximum laser output power amplitude 1.14W was obtained at wavelength 2003nm for absorbed pump power amplitude 4.12W. The laser slope efficiency was 37% in respect to absorbed pumping power. Wavelength tuning was accomplished by using 2mm thick MgF2 birefringent filter placed inside the laser resonator at the Brewster angle. The laser was continuously tunable over 180nm in a spectral region from 1856nm to 2036 nm.

  16. Comparison of rapid diagnostic tests for the detection of Plasmodium vivax malaria in South Korea.

    PubMed

    Kim, Jung-Yeon; Ji, So-Young; Goo, Youn-Kyoung; Na, Byoung-Kuk; Pyo, Hyo-Joo; Lee, Han-Na; Lee, Juyoung; Kim, Nam Hee; von Seidlein, Lorenz; Cheng, Qin; Cho, Shin-Hyung; Lee, Won-Ja

    2013-01-01

    South Korea is one of many countries with endemic Plasmodium vivax malaria. Here we report the evaluation of four rapid diagnostic tests (RDTs) for diagnosis of this disease. A total of 253 subjects were enrolled in the study. The sensitivities, specificities and agreement frequencies were estimated by comparing the four RDTs against the standard of nested-PCR and microscopic examination. The CareStart(TM) and SD Bioline had higher test sensitivities (99.4 and 98.8%, respectively) compared with the NanoSign and Asan Easy tests (93.0 and 94.7%, respectively). The CareStart(TM) and SD Bioline tests could detect P. vivax in samples with parasite densities <150/μl, which was a slightly better performance than the other two RDTs. The quantitative accuracy of the four RDTs was also estimated by comparing results with P. vivax counts from blood samples. Lower test price would result in increased use of these RDTs in the field. The results of this study contribute valuable information that will aid in the selection of a diagnostic method for the detection of malaria.

  17. Comparison of Rapid Diagnostic Tests for the Detection of Plasmodium vivax Malaria in South Korea

    PubMed Central

    Goo, Youn-Kyoung; Na, Byoung-Kuk; Pyo, Hyo-Joo; Lee, Han-Na; Lee, Juyoung; Kim, Nam Hee; von Seidlein, Lorenz; Cheng, Qin; Cho, Shin-Hyung; Lee, Won-Ja

    2013-01-01

    South Korea is one of many countries with endemic Plasmodium vivax malaria. Here we report the evaluation of four rapid diagnostic tests (RDTs) for diagnosis of this disease. A total of 253 subjects were enrolled in the study. The sensitivities, specificities and agreement frequencies were estimated by comparing the four RDTs against the standard of nested-PCR and microscopic examination. The CareStartTM and SD Bioline had higher test sensitivities (99.4 and 98.8%, respectively) compared with the NanoSign and Asan Easy tests (93.0 and 94.7%, respectively). The CareStartTM and SD Bioline tests could detect P. vivax in samples with parasite densities <150/μl, which was a slightly better performance than the other two RDTs. The quantitative accuracy of the four RDTs was also estimated by comparing results with P. vivax counts from blood samples. Lower test price would result in increased use of these RDTs in the field. The results of this study contribute valuable information that will aid in the selection of a diagnostic method for the detection of malaria. PMID:23667710

  18. Methods for destriping Landsat Thematic Mapper images - A feasibility study for an online destriping process in the Thematic Mapper Image Processing System (TIPS)

    NASA Technical Reports Server (NTRS)

    Poros, D. J.; Peterson, C. J.

    1985-01-01

    Methods for destriping TM images and results of the application of these methods to selected TM scenes with sensor and scan striping, which was not removed by the radiometric correction during the TM Archive Generation Phase in TIPS, are presented. These methods correct only for gain and offset differences between detectors over many image lines and do not consider within-line effects. The feasibility of implementing a destriping process online in TIPS is also described.

  19. The promise of copper lowering therapy with tetrathiomolybdate in the cure of cancer and in the treatment of inflammatory disease.

    PubMed

    Brewer, George J

    2014-10-01

    Tetrathiomolybdate (TM) is a unique anticopper drug developed for the treatment of the neurologic presentation of Wilson's disease, for which it is excellent. Since it was known copper was required for angiogenesis, TM was tested on mouse cancer models to see if it would inhibit tumor growth based on an antiangiogenic effect. TM was extremely effective in these models, but all the tumors in the models started small in size - micrometastatic in size. Later, TM was tested in numerous human cancer trials, where it showed only modest effects. However, the mouse lesson of efficacy against micro disease was forgotten - all the trials were against bulky, advanced cancer. Now, the mouse evidence is coming back to life. Three groups are curing, or having major efficacy of TM, against advanced human cancers, heretofore virtually incurable, particularly if the cancer has been reduced to no evidence of disease (NED) status by conventional therapy. In that situation, where the remaining disease is micrometastatic, TM therapy appears to be curative. We have designed and initiated a study of TM in canine osteosarcoma at the micrometastatic phase to help put these findings on a firm scientific basis. TM also has major anti-inflammatory properties by inhibiting copper dependent cytokines involved in inflammation. This anti-inflammatory effect may be involved in TM's anticancer effect because cancers, as they advance, attract inflammatory cells that provide a plethora of additional proangiogenic agents. Copyright © 2014 Elsevier GmbH. All rights reserved.

  20. The Transcendental Meditation Program's Impact on the Symptoms of Post-traumatic Stress Disorder of Veterans: An Uncontrolled Pilot Study.

    PubMed

    Herron, Robert E; Rees, Brian

    2018-01-01

    Current treatments for post-traumatic stress disorder (PTSD) are only partially effective. This study evaluated whether an extensively researched stress reduction method, the Transcendental Meditation (TM) technique, can reduce the PTSD symptoms of veterans. Previous research suggested that TM practice can decrease veterans' PTSD symptoms. A one-group pretest-posttest design was used to evaluate the impact of TM practice on reducing PTSD symptoms. A convenience sample of 89 veterans completed PTSD Checklist-Civilian (PCL-5) questionnaires. Among those, 46 scored above 33, the threshold for provisional diagnosis of PTSD, and were included in this evaluation. The PCL-5 measured PTSD symptoms at baseline and 30 and 90 d after intervention. Regularity of TM practice was recorded. Paired sample t-tests were used to assess within-group changes from baseline to post-intervention periods. Analysis of variance was used to compare full-dose (two 20-min TM sessions per day) and half-dose (one 20-min TM session per day) groups. After 1 mo of TM practice, all 46 veterans responded; their PCL-5 average decreased from 51.52 in the pre-intervention period to a post-intervention mean of 23.43, a decline of 28.09 points (-54.5%); standard deviation: 14.57; confidence interval: 23.76-32.41; and effect size: -1.93; p < 0.0001. The median PTSD scores declined from 52.5 to 22.5, a decrease of 30 points (-57%), while 40 veterans (87%) had clinically significant declines (>10 points) in PTSD symptoms, and 37 (80%) dropped below the clinical level (<33). At the 90 d posttest, 31 of the 46 responded and three more dropped below the 33 threshold. Intent-to-treat analyses revealed clinically and statistically significant effects. A dose-response effect suggested a causal relationship. The full-dose group exhibited larger mean declines in PTSD symptoms than the half-dose group. Averages of the 46 veterans' responses to 20 PCL-5 questions exhibited significant (p < 0.0001) declines from the pre-intervention period to the 30-d post-intervention assessment. Results indicated that TM practice reduced PTSD symptoms without re-experiencing trauma. Because of the magnitude of these results and dose-response effect, regression to the mean, spontaneous remission of symptoms, and placebo effects are unlikely explanations for the results. Major limitations were absence of random assignment and lack of a control group. Participants chose to start and continue TM practice and to complete PCL-5 questionnaires. Those who self-selected to enter this study may not be representative of all veterans who have PTSD. Those who did not complete follow-up questionnaires at 90 d may or may not have had the same results as those who responded. The design and sampling method affect the generalizability of the results to wider populations. When taking into account these results and all previous research on the TM technique in reducing psychological and physiological stress, the convergence of evidence suggests that TM practice may offer a promising adjunct or alternative method for treating PTSD. Because of the widely recognized need to identify effective new approaches for treating PTSD, randomized research with control groups is warranted to further investigate the effectiveness of TM practice as a treatment for PTSD. © Association of Military Surgeons of the United States 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  1. Technical note: patient-specific quality assurance methods for TomoDirect(TM) whole breast treatment delivery.

    PubMed

    Catuzzo, P; Zenone, F; Aimonetto, S; Peruzzo, A; Casanova Borca, V; Pasquino, M; Franco, P; La Porta, M R; Ricardi, U; Tofani, S

    2012-07-01

    To investigate the feasibility of implementing a novel approach for patient-specific QA of TomoDirect(TM) whole breast treatment. The most currently used TomoTherapy DQA method, consisting in the verification of the 2D dose distribution in a coronal or sagittal plane of the Cheese Phantom by means of gafchromic films, was compared with an alternative approach based on the use of two commercially available diode arrays, MapCHECK2(TM) and ArcCHECK(TM). The TomoDirect(TM) plans of twenty patients with a primary unilateral breast cancer were applied to a CT scan of the Cheese Phantom and a MVCT dataset of the diode arrays. Then measurements of 2D dose distribution were performed and compared with the calculated ones using the gamma analysis method with different sets of DTA and DD criteria (3%-3 mm, 3%-2 mm). The sensitivity of the diode arrays to detect delivery and setup errors was also investigated. The measured dose distributions showed excellent agreement with the TPS calculations for each detector, with averaged fractions of passed Γ values greater than 95%. The percentage of points satisfying the constraint Γ < 1 was significantly higher for MapCHECK2(TM) than for ArcCHECK(TM) and gafchromic films using both the 3%-3 mm and 3%-2 mm gamma criteria. Both the diode arrays show a good sensitivity to delivery and setup errors using a 3%-2 mm gamma criteria. MapCHECK2™ and ArcCHECK(TM) may fulfill the demands of an adequate system for TomoDirect(TM) patient-specific QA.

  2. U.S. Navy Unmanned Test Methods and Performance Limits for Underwater Breathing Apparatus

    DTIC Science & Technology

    2015-06-01

    in liters per minute (STPD) ?̇?2 Metabolic oxygen consumption in liters per minute (STPD) max Maximum flow rate ?̇? Ventilation , first time...8-2 8.1.3 Oxygen consumption ... OXYGEN CONSUMPTION SIMULATION ........................................................................... 9-1 CHAPTER 9. NEDU TM 15-01 vii 9-1

  3. A small-scale randomised controlled trial of home telemonitoring in patients with severe chronic obstructive pulmonary disease.

    PubMed

    Shany, Tal; Hession, Michael; Pryce, David; Roberts, Mary; Basilakis, Jim; Redmond, Stephen; Lovell, Nigel; Schreier, Guenter

    2017-08-01

    Introduction This was a pilot study to examine the effects of home telemonitoring (TM) of patients with severe chronic obstructive pulmonary disease (COPD). Methods A randomised controlled 12-month trial of 42 patients with severe COPD was conducted. Home TM of oximetry, temperature, pulse, electrocardiogram, blood pressure, spirometry, and weight with telephone support and home visits was tested against a control group receiving only identical telephone support and home visits. Results The results suggest that TM had a reduction in COPD-related admissions, emergency department presentations, and hospital bed days. TM also seemed to increase the interval between COPD-related exacerbations requiring a hospital visit and prolonged the time to the first admission. The interval between hospital visits was significantly different between the study arms, while the other findings did not reach significance and only suggest a trend. There was a reduction in hospital admission costs. TM was adopted well by most patients and eventually, also by the nursing staff, though it did not seem to change patients' psychological well-being. Discussion Ability to draw firm conclusions is limited due to the small sample size. However the trends of reducing hospital visits warrant a larger study of a similar design. When designing such a trial, one should consider the potential impact of the high quality of care already made available to this patient cohort.

  4. Role of the Lipid Environment in the Dimerization of Transmembrane Domains of Glycophorin A

    PubMed Central

    Kuznetsov, A. S.; Volynsky, P. E.; Efremov, R. G.

    2015-01-01

    An efficient computational approach is developed to quantify the free energy of a spontaneous association of the α-helices of proteins in the membrane environment. The approach is based on the numerical decomposition of the free energy profiles of the transmembrane (TM) helices into components corresponding to protein-protein, protein-lipid, and protein-water interactions. The method was tested for the TM segments of human glycophorin A (GpA) and two mutant forms, Gly83Ala and Thr87Val. It was shown that lipids make a significant negative contribution to the free energy of dimerization, while amino acid residues forming the interface of the helix-helix contact may be unfavorable in terms of free energy. The detailed balance between different energy contributions is highly dependent on the amino acid sequence of the TM protein segment. The results show the dominant role of the environment in the interaction of membrane proteins that is changing our notion of the driving force behind the spontaneous association of TM α-helices. Adequate estimation of the contribution of the water-lipid environment thus becomes an extremely urgent task for a rational design of new molecules targeting bitopic membrane proteins, including receptor tyrosine kinases. PMID:26798499

  5. Test Takers' Attitudes about the TOEFL iBT[TM]. TOEFL iBT Research Report. RR-10-2

    ERIC Educational Resources Information Center

    Stricker, Lawrence J.; Attali, Yigal

    2010-01-01

    The principal aims of this study, a conceptual replication of an earlier investigation of the TOEFL[R] computer-based test, or TOEFL CBT, in Buenos Aires, Cairo, and Frankfurt, were to assess test takers' reported acceptance of the TOEFL Internet-based test, or TOEFL iBT[TM], and its associations with possible determinants of this acceptance and…

  6. Quantitative comparison of tympanic membrane displacements using two optical methods to recover the optical phase

    NASA Astrophysics Data System (ADS)

    Santiago-Lona, Cynthia V.; Hernández-Montes, María del Socorro; Mendoza-Santoyo, Fernando; Esquivel-Tejeda, Jesús

    2018-02-01

    The study and quantification of the tympanic membrane (TM) displacements add important information to advance the knowledge about the hearing process. A comparative statistical analysis between two commonly used demodulation methods employed to recover the optical phase in digital holographic interferometry, namely the fast Fourier transform and phase-shifting interferometry, is presented as applied to study thin tissues such as the TM. The resulting experimental TM surface displacement data are used to contrast both methods through the analysis of variance and F tests. Data are gathered when the TMs are excited with continuous sound stimuli at levels 86, 89 and 93 dB SPL for the frequencies of 800, 1300 and 2500 Hz under the same experimental conditions. The statistical analysis shows repeatability in z-direction displacements with a standard deviation of 0.086, 0.098 and 0.080 μm using the Fourier method, and 0.080, 0.104 and 0.055 μm with the phase-shifting method at a 95% confidence level for all frequencies. The precision and accuracy are evaluated by means of the coefficient of variation; the results with the Fourier method are 0.06143, 0.06125, 0.06154 and 0.06154, 0.06118, 0.06111 with phase-shifting. The relative error between both methods is 7.143, 6.250 and 30.769%. On comparing the measured displacements, the results indicate that there is no statistically significant difference between both methods for frequencies at 800 and 1300 Hz; however, errors and other statistics increase at 2500 Hz.

  7. Phase I Forest Area Estimation Using Landsat TM and Iterative Guided Spectral Class Rejection: Assessment of Possible Training Data Protocols

    Treesearch

    John A. Scrivani; Randolph H. Wynne; Christine E. Blinn; Rebecca F. Musy

    2001-01-01

    Two methods of training data collection for automated image classification were tested in Virginia as part of a larger effort to develop an objective, repeatable, and low-cost method to provide forest area classification from satellite imagery. The derived forest area estimates were compared to estimates derived from a traditional photo-interpreted, double sample. One...

  8. Evaluation of atmospheric particulate concentrations derived from analysis of ratio Thematic Mapper data

    NASA Technical Reports Server (NTRS)

    Carnahan, W. H.; Mausel, P. W.; Zhou, G. P.

    1984-01-01

    An approach for atmospheric particulate concentration evaluation above urban areas using ratio Thematic Mapper (TM) data is discussed. October 25, 1982 TM data over Chicago, IL are analyzed using TM band ratios of 1/2, 1/3, 1/4, 1/5, and 1/6 and particulate concentration estimates derived from TM ratios are tested over low reflective turbid water sites and highly reflective concrete highways. From analysis of the data it is evident that for water, the pattern of increasing particulate concentration is associated with decreasing ratio values in all band combinations used. Over concrete features, the TM band 1/4 ratio values follow the predicted pattern, while the TM band 1/6 has ratios which are reversed from anticipated values.

  9. Evaluation of sample preparation methods for the detection of total metal content using inductively coupled plasma optical emission spectrometry (ICP-OES) in wastewater and sludge

    NASA Astrophysics Data System (ADS)

    Dimpe, K. M.; Ngila, J. C.; Mabuba, N.; Nomngongo, P. N.

    Heavy metal contamination exists in aqueous wastes and sludge of many industrial discharges and domestic wastewater, among other sources. Determination of metals in the wastewater and sludge requires sample pre-treatment prior to analysis because of certain challenges such as the complexity of the physical state of the sample, which may lead to wrong readings in the measurement. This is particularly the case with low analyte concentration to be detected by the instrument. The purpose of this work was to assess and validate the different sample preparation methods namely, hot plate and microwave-assisted digestion procedures for extraction of metal ions in wastewater and sludge samples prior to their inductively coupled plasma optical emission spectrometric (ICP-OES) determination. For the extraction of As, Al, Cd, Cr, Cu, Fe, Mn, Ni, Pb, Zn, three acid mixtures, that is, HNO3/H2O2, HNO3/HClO4/H2O2 and aqua regia + H2O2, were evaluated. Influent wastewater spiked with the SRM (CWW-TM-B) was used for the optimization of acid mixtures affecting the extraction procedure. After sample digestion, the filtration capabilities of cellulose-acetate filter paper and the acrodisc syringe filter with the pore size of 0.45 μm were compared. In terms of performance, acrodisc syringe filter in terms of the improved recoveries obtained, was found to be the best filtration method compared to the filter paper. Based on the analytical results obtained, microwave-assisted digestion (MAD) using aqua regia + H2O2 mixture was found to be the most suitable method for extraction of heavy metals and major elements in all the sample matrices. Therefore, MAD using aqua regia + H2O2 mixture was used for further investigations. The precision of the developed MAD method expressed in terms of relative standard deviations (% RSD) for different metals was found to be <5%. The limits of detection (LOD) and limits of quantification (LOQ) ranged from 0.12% to 2.18 μg L-1 and 0.61% to 3.43 μg L-1, respectively. The accuracy of the developed method (MAD using aqua regia + H2O2) was verified by analyzing two SRMs (CWW-TM-A and CWW-TM-B) and the obtained results were in agreement with certified values with recoveries ranging from 80% to 104% for CWW-TM-A and 84% to 102% for CWW-TM-B. The accuracy of the developed method was verified also by the recovery test in the spiked sludge samples. The accuracy and spike recovery test for different metal ions were in the range 80-104% and 92-106%, respectively. The developed method was applied for extraction of the As, Al, Cd, Cr, Cu, Fe, Mn, Ni, Pb, Zn in environmental samples, namely wastewater and sludge.

  10. Furostanolic saponins from Trigonella foenum-graecum alleviate diet-induced glucose intolerance and hepatic fat accumulation.

    PubMed

    Hua, Yinan; Ren, Sidney Y; Guo, Rui; Rogers, Olivia; Nair, Rama P; Bagchi, Debasis; Swaroop, Anand; Nair, Sreejayan

    2015-10-01

    The objective of this study was to evaluate the effect of fenugreek furostanolic saponins (Fenfuro(TM) ) either alone or in combination with chlorogenic acid (GCB-70(TM) ) on insulin resistance in mice. Male C57BL/6J mice were subjected to a normal or high-fat diet (HFD) and were randomly assigned to receive Fenfuro(TM) , GCB-70(TM) , or their combination for 24 wk. Metabolic parameters, glucose tolerance, serum triglycerides, cardiac function, and hepatic insulin signaling were evaluated using indirect open-circuit calorimetry, intraperitoneal glucose tolerance test, oil red O staining, echocardiography, and Western blotting, respectively. Intraperitoneal glucose tolerance test revealed glucose intolerance in the mice receiving HFD, which was attenuated by Fenfuro(TM) . Serum triglyceride that was elevated following an HFD was reconciled by both Fenfuro(TM) and the combination. HFD compromised myocardial contractile function, which was unaffected by the treatment. Insulin-stimulated phosphorylation of Protein kinase B (AKT) in the liver was attenuated in mice receiving HFD, which was partially rescued by GCB-70(TM) . Neither treatment altered metabolic parameters or energy expenditure. Collectively, our data suggest that fenugreek furostanolic saponins and green coffee bean extract may have potential benefits in treating insulin resistance and related conditions. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Fabrication and Luminescence Characterization of a Silica Nanomatrix Embedded with NaYF4:Yb:Er:Tm@NaGdF4/Fe3O4 Nanoparticles

    NASA Astrophysics Data System (ADS)

    Thangaraju, Dheivasigamani; Santhana, Vedi; Matsuda, Satoshi; Hayakawa, Yasuhiro

    2018-05-01

    Hexagonal NaYF4:Yb:Er:Tm@NaGdF4 core-shell nanocrystals were synthesized using a seed mediated hot injection method, and monodispersed Fe3O4 (4 nm) nanoparticles were prepared from iron(II) actylacetonate by a precursor thermal decomposition method. Structural and morphology verified NaYF4:Yb:Er:Tm@NaGdF4 and Fe3O4 nanoparticles were utilized for the preparation of NaYF4:Yb:Er:Tm@NaGdF4/Fe3O4@SiO2 nanocomposite using a micro-emulsion method. Existence of Fe3O4 in NaYF4:Yb:Er:Tm@NaGdF4 in SiO2 nano-spheres were confirmed with transmission electron microscopy. Luminescence measurement revealed that NaYF4:Yb:Er:Tm@NaGdF4 exhibited strong emissions at green and red regions, in addition to a weak blue emission also observed under 980 nm excitation. Up-conversion emission of the nanoparticle-embedded silica nanocomposite showed that the up-conversion emission was not affected by Fe3O4 nanoparticles.

  12. A technique for the reduction of banding in Landsat Thematic Mapper Images

    USGS Publications Warehouse

    Helder, Dennis L.; Quirk, Bruce K.; Hood, Joy J.

    1992-01-01

    The radiometric difference between forward and reverse scans in Landsat thematic mapper (TM) images, referred to as "banding," can create problems when enhancing the image for interpretation or when performing quantitative studies. Recent research has led to the development of a method that reduces the banding in Landsat TM data sets. It involves passing a one-dimensional spatial kernel over the data set. This kernel is developed from the statistics of the banding pattern and is based on the Wiener filter. It has been implemented on both a DOS-based microcomputer and several UNIX-based computer systems. The algorithm has successfully reduced the banding in several test data sets.

  13. Post-marketing surveillance of thrombomodulin alfa, a novel treatment of disseminated intravascular coagulation - safety and efficacy in 1,032 patients with hematologic malignancy.

    PubMed

    Asakura, Hidesaku; Takahashi, Hoyu; Tsuji, Hajime; Matsushita, Tadashi; Ninomiya, Hideyuki; Honda, Goichi; Mimuro, Jun; Eguchi, Yutaka; Kitajima, Isao; Sakata, Yoichi

    2014-03-01

    Post-marketing surveillance of thrombomodulin alfa (TM-α) was performed to evaluate safety and efficacy in patients with disseminated intravascular coagulation (DIC) with hematologic malignancy. All patients treated with TM-α from May 2008 to April 2010 in Japan were included. Information about baseline characteristics, safety, and efficacy were collected. The DIC resolution rate, survival rate on Day 28 after the last TM-α administration, and changes in DIC score and coagulation tests were evaluated. The underlying diseases associated with DIC were acute myeloid leukemia (except for acute promyelocytic leukemia, n=350), lymphoma (n=199), acute promyelocytic leukemia (n=172), acute lymphoblastic leukemia (n=156), myelodysplastic syndromes (n=61), and other (n=94). The incidence rates of bleeding-related adverse events and adverse drug reactions were 17.8% and 4.6%, respectively. In subjects with bleeding symptoms at baseline, 55.0% were assessed as disappeared or improved based on symptoms after TM-α treatment. The DIC resolution and survival rates were 55.9% and 70.7%, respectively. The DIC score and coagulation tests including thrombin-antithrombin complex (TAT) were significantly improved. Coagulation tests were significantly improved after TM-α treatment even in subjects whose clinical course of underlying disease was assessed as unchanged or exacerbated. This surveillance confirmed the safety and efficacy of TM-α in clinical practice, thus TM-α may be an ideal treatment for patients with DIC based upon hematologic malignancy. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Silver nanoparticles-based colorimetric array for the detection of Thiophanate-methyl

    NASA Astrophysics Data System (ADS)

    Zheng, Mingda; Wang, Yingying; Wang, Chenge; Wei, Wei; Ma, Shuang; Sun, Xiaohan; He, Jiang

    2018-06-01

    A simple and selective colorimetric sensor based on citrate capped silver nanoparticles (Cit-AgNPs) is proposed for the detection of Thiophanate-methyl (TM) with high sensitivity and selectivity. The method based on the color change of Cit-AgNPs from yellow to cherry red with the addition of TM to Cit-AgNPs that caused a red-shift on the surface plasmon resonance (SPR) band from 394 nm to 525 nm due to the hydrogen-bonding and substitution. The density functional theory (DFT) method was also calculated the interactions between the TM and citrate ions. Under the optimized conditions, a linear relationship between the absorption ratio (A525nm/A394nm) and TM concentration was found in the range of 2-100 μM with correlation coefficient (R2) of 0.988. The detection limit of TM was 0.12 μM by UV-vis spectrometer. Moreover, the applicability of colorimetric sensor is successfully verified by the detection of TM in environmental samples with good recoveries.

  15. Percutaneous toxicity and decontamination of soman, VX, and paraoxon in rats using detergents.

    PubMed

    Misík, Jan; Pavliková, Růžena; Kuča, Kamil

    2013-06-01

    Highly toxic organophosphorus compounds (OPs) were originally developed for warfare or as agricultural pesticides. Today, OPs represent a serious threat to military personnel and civilians. This study investigates the in vivo decontamination of male Wistar rats percutaneously exposed to paraoxon and two potent nerve agents--soman (GD) and VX. Four commercial detergents were tested as decontaminants--Neodekont(TM), Argos(TM), Dermogel(TM), and FloraFree(TM). Decontamination performed 2 min after exposure resulted in a higher survival rate in comparison with non-decontaminated controls. The decontamination effectiveness was expressed as protective ratio (PR, median lethal dose of agent in decontaminated animals divided by the median lethal dose of agent in untreated animals). The highest decontamination effectiveness was consistently achieved with Argos(TM) (PR=2.3 to 64.8), followed by Dermogel(TM) (PR=2.4 to 46.1). Neodekont(TM) and FloraFree(TM) provided the lowest decontamination effectiveness, equivalent to distilled water (PR=1.0 to 43.2).

  16. A DFT investigation on group 8B transition metal-doped silicon carbide nanotubes for hydrogen storage application

    NASA Astrophysics Data System (ADS)

    Tabtimsai, Chanukorn; Ruangpornvisuti, Vithaya; Tontapha, Sarawut; Wanno, Banchob

    2018-05-01

    The binding of group 8B transition metal (TMs) on silicon carbide nanotubes (SiCNT) hydrogenated edges and the adsorption of hydrogen molecule on the pristine and TM-doped SiCNTs were investigated using the density functional theory method. The B3LYP/LanL2DZ method was employed in all calculations for the considered structural, adsorption, and electronic properties. The Os atom doping on the SiCNT is found to be the strongest binding. The hydrogen molecule displays a weak interaction with pristine SiCNT, whereas it has a strong interaction with TM-doped SiCNTs in which the Os-doped SiCNT shows the strongest interaction with the hydrogen molecule. The improvement in the adsorption abilities of hydrogen molecule onto TM-doped SiCNTs is due to the protruding structure and the induced charge transfer between TM-doped SiCNT and hydrogen molecule. These observations point out that TM-doped SiCNTs are highly sensitive toward hydrogen molecule. Moreover, the adsorptions of 2-5 hydrogen molecules on TM-doped SiCNT were also investigated. The maximum storage number of hydrogen molecules adsorbed on the first layer of TM-doped SiCNTs is 3 hydrogen molecules. Therefore, TM-doped SiCNTs are suitable to be sensing and storage materials for hydrogen gas.

  17. Preliminary Study of Information Extraction of LANDSAT TM Data for a Suburban/regional Test Site

    NASA Technical Reports Server (NTRS)

    Toll, D. L.

    1985-01-01

    A substantial amount of spectral information is available from TM (as compared to MSS) data for a 14.25 square km area between Beltsville and Laurel, Maryland. Large buildings and street patterns were resolved in the TM imagery. While there was added information content in TM data for discriminating surburban/regional land cover, characteristics of MSS can improve land cover discrimination over TM when conventional classification procedures are used on digital data. The improved qualitization of TM is likely valuable in situations where there are spectral similarities between classes. The spatial resolution in TM decreased land cover discrimination as a result of increased within class variability. For many general digital evaluations, inclusion of four bands representing the four spectral regions can provide much useful land cover discrimination. Inclusion of TM 6 indicates an improvement in spectral class discrimination. Of primary spectral importance is the discrimination between water, vegetative surfaces, and impervious surfaces due to differences in thermal properties. Results from the principle component transformed data clearly indicates additional information content in TM over MSS.

  18. Probing structure, thermochemistry, electron affinity, and magnetic moment of thulium-doped silicon clusters TmSi n (n = 3-10) and their anions with density functional theory.

    PubMed

    Huang, Xintao; Yang, Jucai

    2017-12-26

    The most stable structures and electronic properties of TmSi n (n = 3-10) clusters and their anions have been probed by using the ABCluster global search technique combined with the PBE, TPSSh, and B3LYP density functional methods. The results revealed that the most stable structures of neutral TmSi n and their anions can be regarded as substituting a Si atom of the ground state structure of Si n + 1 with a Tm atom. The reliable AEAs, VDEs and simulated PES of TmSi n (n = 3-10) are presented. Calculations of HOMO-LUMO gap revealed that introducing Tm atom to Si cluster can improve photochemical reactivity of the cluster. The NPA analyses indicated that the 4f electron of Tm atom in TmSi n (n = 3-10) and their anions do not participate in bonding. The total magnetic moments of TmSi n are mainly provided by the 4f electrons of Tm atom. The dissociation energy of Tm atom from the most stable structure of TmSi n and their anions has been calculated to examine relative stability.

  19. Value of Information Analysis of Multiparameter Tests for Chemotherapy in Early Breast Cancer: The OPTIMA Prelim Trial.

    PubMed

    Hall, Peter S; Smith, Alison; Hulme, Claire; Vargas-Palacios, Armando; Makris, Andreas; Hughes-Davies, Luke; Dunn, Janet A; Bartlett, John M S; Cameron, David A; Marshall, Andrea; Campbell, Amy; Macpherson, Iain R; Dan Rea; Francis, Adele; Earl, Helena; Morgan, Adrienne; Stein, Robert C; McCabe, Christopher

    2017-12-01

    Precision medicine is heralded as offering more effective treatments to smaller targeted patient populations. In breast cancer, adjuvant chemotherapy is standard for patients considered as high-risk after surgery. Molecular tests may identify patients who can safely avoid chemotherapy. To use economic analysis before a large-scale clinical trial of molecular testing to confirm the value of the trial and help prioritize between candidate tests as randomized comparators. Women with surgically treated breast cancer (estrogen receptor-positive and lymph node-positive or tumor size ≥30 mm) were randomized to standard care (chemotherapy for all) or test-directed care using Oncotype DX™. Additional testing was undertaken using alternative tests: MammaPrint TM , PAM-50 (Prosigna TM ), MammaTyper TM , IHC4, and IHC4-AQUA™ (NexCourse Breast™). A probabilistic decision model assessed the cost-effectiveness of all tests from a UK perspective. Value of information analysis determined the most efficient publicly funded ongoing trial design in the United Kingdom. There was an 86% probability of molecular testing being cost-effective, with most tests producing cost savings (range -£1892 to £195) and quality-adjusted life-year gains (range 0.17-0.20). There were only small differences in costs and quality-adjusted life-years between tests. Uncertainty was driven by long-term outcomes. Value of information demonstrated value of further research into all tests, with Prosigna currently being the highest priority for further research. Molecular tests are likely to be cost-effective, but an optimal test is yet to be identified. Health economics modeling to inform the design of a randomized controlled trial looking at diagnostic technology has been demonstrated to be feasible as a method for improving research efficiency. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  20. In vitro and in vivo Safety Evaluation of NephureTM

    PubMed Central

    Cowley, Helena; Yan, Qin; Koetzner, Lee; Dolan, Laurie; Nordwald, Erik; Cowley, Aaron B.

    2017-01-01

    NephureTM is a proprietary oxalate decarboxylase (OxDC) enzyme being developed as a food ingredient. In this study, the safety of NephureTM was evaluated in a bacterial mutagenicity assay and in a sub-chronic (13-week) oral toxicity study in rats. NephureTM did not show any mutagenic properties in the mutagenicity assay. In the 13-week sub-chronic oral toxicity study in which 10 Sprague Dawley rats per sex were administered 0, 118, 235 and 475 mg/kg bw/day (8260, 16450 and 33,250 Units/kg bw/day, respectively) of NephureTM by gavage, male and female rats did not show any test article-related clinical observations or effects on body weight, body weight gain, food consumption, food efficiency, ophthalmology, functional observational battery parameters or motor activity. Furthermore, there were no changes in coagulation, clinical chemistry, urinalysis or hematology parameters, macroscopic/microscopic findings or organ weights that could be attributed to the test article. Based on these results, NephureTM was not mutagenic and the no-adverse-effect level (NOAEL) in the 13-week study was determined to be 475 mg/kg bw/day (33,250 Units/kg bw/day). Evaluation of the estimated consumption of NephureTM, generation of the metabolite formate, and the current safety studies resulted in a conclusion of a tolerable upper limit of 3450 Units of OxDC activity/day (57.5 Units activity/kg bw/day), when NephureTM is added to food to decrease dietary oxalate. PMID:28322893

  1. Failure of non-vacuum steam sterilization processes for dental handpieces.

    PubMed

    Winter, S; Smith, A; Lappin, D; McDonagh, G; Kirk, B

    2017-12-01

    Dental handpieces are used in critical and semi-critical operative interventions. Although some dental professional bodies recommend that dental handpieces are sterilized between patient use there is a lack of clarity and understanding of the effectiveness of different steam sterilization processes. The internal mechanisms of dental handpieces contain narrow lumens (0.8-2.3 mm) which can impede the removal of air and ingress of saturated steam required to achieve sterilization conditions. To identify the extent of sterilization failure in dental handpieces using a non-vacuum process. In-vitro and in-vivo investigations were conducted on widely used UK bench-top steam sterilizers and three different types of dental handpieces. The sterilization process was monitored inside the lumens of dental handpieces using thermometric (TM; dataloggers), chemical indicator (CI), and biological indicator (BI) methods. All three methods of assessing achievement of sterility within dental handpieces that had been exposed to non-vacuum sterilization conditions demonstrated a significant number of failures [CI: 8/3024 (fails/no. of tests); BI: 15/3024; TM: 56/56] compared to vacuum sterilization conditions (CI: 2/1944; BI: 0/1944; TM: 0/36). The dental handpiece most likely to fail sterilization in the non-vacuum process was the surgical handpiece. Non-vacuum sterilizers located in general dental practice had a higher rate of sterilization failure (CI: 25/1620; BI: 32/1620; TM: 56/56) with no failures in vacuum process. Non-vacuum downward/gravity displacement, type N steam sterilizers are an unreliable method for sterilization of dental handpieces in general dental practice. The handpiece most likely to fail sterilization is the type most frequently used for surgical interventions. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  2. Evaluation of NGAL TestTM on Cobas 6000.

    PubMed

    Hansen, Young B L; Damgaard, Anette; Poulsen, Jørgen H

    2014-01-01

    Neutrophil Gelatinase-Associated Lipocalin (NGAL) is a promising biomarker for acute kidney injury (AKI). Our objectives were to evaluate the NGAL Test(TM) from Bioporto for both urine NGAL and plasma NGAL on the Cobas 6000 c501 (Roche Diagnostics, Rotkreuz, Switzerland) with matched measurements run on Hitachi 917, the method's linearity on the Cobas 6000 in urine, EDTA and Lithium-Heparin (Li-Hep), the influence of using EDTA or Li-Hep tubes and, finally, the impact of freezing and thawing on the sample. Forty matched samples of Li-Hep and EDTA plasma and 40 urine samples were analyzed for method, anticoagulant, and freeze-thaw comparisons. Linearity was assessed using high NGAL samples diluted in urine, EDTA, and Li-Hep plasma. Commercial internal controls were used for the imprecision study. The Cobas 6000 measured identically with the Hitachi 917, however, not in EDTA plasma (Median Difference = 17.50 μg/L, p < 0.0001). Freeze-thaw process reduced NGAL ((EDTA: Mean Difference = = 15.13 μg/L, p = 0.0014)(Li-Hep: Median Difference = = 6.5 μg/L, p = 0.0129)). NGAL results were higher in Li-Hep plasma than in EDTA plasma ((Non-thawed: Median Difference = = 14.5 μg/L, p < 0.0001), (Thawed: Median Difference = = 21.5 μg/L, p = 0.0003)). Linearity agreements were observed in all three specimens. Imprecision (CV%) was below 3%. The NGAL Test(TM) can be applied on the Cobas 6000 with acceptable performance, although the Cobas 6000 measured higher than the Hitachi 917 in EDTA plasma. Though clinically insignificant, we found that the freeze-thaw process had a reduced effect. NGAL results were higher in Li-Hep tubes than in EDTA tubes. Thus, for blood samples we recommend use of EDTA tubes for NGAL measurements.

  3. Real-time PCR for Leishmania species identification: Evaluation and comparison with classical techniques.

    PubMed

    de Morais, Rayana Carla Silva; da Costa Oliveira, Cintia Nascimento; de Albuquerque, Suênia da Cunha Gonçalves; Mendonça Trajano Silva, Lays Adrianne; Pessoa-E-Silva, Rômulo; Alves da Cruz, Heidi Lacerda; de Brito, Maria Edileuza Felinto; de Paiva Cavalcanti, Milena

    2016-06-01

    Cutaneous leishmaniasis (CL) is a parasitic disease caused by various Leishmania species. Several studies have shown that real time quantitative PCR (qPCR) can be used for Leishmania spp. identification by analyzing the melting temperature (Tm). Thus, the aim of this study was to evaluate the viability of qPCR for differentiating eight closely related Leishmania species that cause the same clinical form of the disease and to compare the results with classical techniques. qPCR assays for standardizing the Tm using reference strains were performed. After the CL diagnosis on blood samples of domestic animals, positive samples were analyzed by their Tm and qPCR products were purified and sequenced. Ten human samples previously characterized by Multilocus Enzyme Electrophoresis (MLEE) were also analyzed by Tm. A Restriction Fragment Length Polymorphism (RFLP) assay, a reference test, was also standardized, by using the reference strains. Through standardization of Tm for Leishmania spp., two Tm ranges were created for analysis: 1 (Tm = 78-79.99 °C) included Leishmania (V.) braziliensis, Leishmania (V.) panamensis, Leishmania (V.) lainsoni, Leishmania (V.) guyanensis and Leishmania (V.) shawi; and 2 (Tm = 80-82.2 °C) included Leishmania (V.) naiffi, Leishmania (L.) amazonensis and Leishmania (L.) mexicana. A total of 223 positive blood samples were analyzed, with 58 included in range 1 and 165 in range 2. L. (V.) braziliensis, L. (V.) panamensis and L. (V.) guyanensis were identified by sequencing, while L. (V.) braziliensis, L. (L.) mexicana and L. (V.) panamensis were identified by RFLP analysis. Ten human samples previously characterized by Multilocus Enzyme Electrophoresis (MLEE) were also analyzed by qPCR Tm analysis; five were classified in range 1 and five in range 2. A concordance of 80% was calculated between qPCR and the gold-standard (MLEE) with no significant difference between the methods (p = 0.6499); a similar result was observed for sequencing and qPCR (p = 0.2566). In contrast, a highly significant difference was observed for qPCR and RFLP (p < 0.001). In this study, we demonstrated the potential use of qPCR as a tool for Leishmania species identification using two Tm ranges. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Luminescent properties of Tm3-xLuxAl5O12:Ce single crystalline films

    NASA Astrophysics Data System (ADS)

    Zorenko, Yu.; Gorbenko, V.; Zorenko, T.; Suchocki, A.; Zhydachevskyy, Ya.; Fabisiak, K.; Paprocki, K.; Bilski, P.; Twardak, A.; Fedorov, A.

    2017-07-01

    The work devoted to the investigation of a new luminescent and scintillation material based on the single crystalline films (SCFs) of Tm3-xLuxAG:Ce garnet; x = 0-1.5, grown by LPE method from PbO based flux. The best scintillation properties are achieved for SCFs of Tm1.5Lu1.5Al5O12:Ce composition. We have found that direct Tm → Ce and backside Ce → Tm energy transfer processes are observed in Tm1.5Lu1.5Al5O12:Ce. Due to elimination of traps in the 300-450 °C range, the relatively fast scintillation decay is realized in highly doped Tm1.5Lu1.5Al5O12:Ce SCFs. For this reason, Tm doping can be considered as a suitable way for improvement of the scintillation efficiency in other Ce3+ doped garnet compounds.

  5. Three Randomized Experiments on the Longitudinal Effects of the Transcendental Meditation Technique on Cognition.

    ERIC Educational Resources Information Center

    So, Kam-Tim; Orme-Johnson, David W.

    2001-01-01

    Three studies of 362 high school students in 3 schools in Taiwan tested the hypothesis that regular practice of transcendental meditation (TM) for 6 to 12 months would improve cognitive ability. TM practice produced significant effects on all seven variables studies, and the TM technique was superior to contemplative meditation for five of the…

  6. Up-conversion luminescence properties and energy transfer of Tm{sup 3+}/Yb{sup 3+} co-doped BaLa{sub 2}ZnO{sub 5}

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xie, Jing; Mei, Lefu, E-mail: mlf@cugb.edu.cn; Deng, Junru

    2015-11-15

    Tm{sup 3+}/Yb{sup 3+} co-doped BaLa{sub 2}ZnO{sub 5} up-conversion (UC) phosphors were successfully synthesized by high temperature solid-state reaction method. The X-ray diffraction (XRD) results show that synthesized phosphor co-doped with 0.75% Tm/10% Yb has the optimum pure phase of BaLa{sub 2}ZnO{sub 5} among different co-doping concentrations. The structure of BaLa{sub 2}ZnO{sub 5}:0.75% Tm/10% Yb phosphor was refined by the Rietveld method and results show the decreased unit cell parameters and cell volume after doping Tm{sup 3+}/Yb{sup 3+}, indicating that Tm{sup 3+}/Yb{sup 3+} have successfully replaced La{sup 3+}. Under excitation at 980 nm, Tm{sup 3+}/Yb{sup 3+} co-doped BaLa{sub 2}ZnO{sub 5} phosphorsmore » present bright blue emission near 478 nm generated by the {sup 1}G{sub 4}→{sup 3}H{sub 6} transition and weak red emissions around 653 nm and 692 nm generated by the {sup 1}G{sub 4}→{sup 3}F{sub 4} and {sup 3}F{sub 3}→{sup 3}H{sub 6} transitions of Tm{sup 3+}, respectively. The UC luminescence properties of BaLa{sub 2}ZnO{sub 5} phosphors co-doped with different Tm{sup 3+}/Yb{sup 3+} concentrations were investigated, and the related UC mechanisms of Tm{sup 3+}/Yb{sup 3+} co-doped BaLa{sub 2}ZnO{sub 5} depending on pump power were studied in detail. - Graphical abstract: Up-conversion luminescence of BaLa{sub 2}ZnO{sub 5}:Tm{sup 3+}/Yb{sup 3+} and its crystal structure and up-conversion mechanisms. - Highlights: • Up-conversion phosphors BaLa{sub 2}ZnO{sub 5} co-doped with Tm{sup 3+}/Yb{sup 3+} were synthesized by high temperature solid-state reaction method. • The crystal structure of BaLa{sub 2}ZnO{sub 5} and the changes of cell parameters and volume of BaLa{sub 2}ZnO{sub 5} after doping Tm{sup 3+} and Yb{sup 3+} have been discussed. • Up-conversion luminescence properties and energy transfer between Tm{sup 3+} and Yb{sup 3+} in BaLa{sub 2}ZnO{sub 5} have been discussed in detail.« less

  7. Inhibition of allergic bronchial asthma by thrombomodulin is mediated by dendritic cells.

    PubMed

    Takagi, Takehiro; Taguchi, Osamu; Toda, Masaaki; Ruiz, Daniel Boveda; Bernabe, Paloma Gil; D'Alessandro-Gabazza, Corina N; Miyake, Yasushi; Kobayashi, Tetsu; Aoki, Shinya; Chiba, Fumiko; Yano, Yutaka; Conway, Edward M; Munesue, Seiichi; Yamamoto, Yasuhiko; Yamamoto, Hiroshi; Suzuki, Koji; Takei, Yoshiyuki; Morser, John; Gabazza, Esteban C

    2011-01-01

    bronchial asthma is caused by inappropriate acquired immune responses to environmental allergens. It is a major health problem, with a prevalence that is rapidly increasing. Curative therapy is not currently available. to test the hypothesis that thrombomodulin (TM) inhibits allergic bronchial asthma by inducing tolerogenic dendritic cells (DCs). the protective effect of TM was evaluated using a murine asthma model. Asthma was induced in mice by exposure to chicken egg ovalbumin, and the effects of inhaled TM or TM-treated DCs were assessed by administering before ovalbumin exposure. treatment with TM protects against bronchial asthma measured as improved lung function and reduced IgE and cells in alveolar lavage fluid by inducing tolerogenic dendritic dells. These are characterized by high expression of surface TM (CD141/TM(+)) and low expression of maturation markers and possess reduced T-cell costimulatory activity. The CD141/TM(+) DCs migrate less toward chemokines, and after TM treatment there are fewer DCs in the draining lymph node and more in the lungs. The TM effect is independent of its role in coagulation. Rather, it is mediated via the TM lectin domain directly interacting with the DCs. the results of this study show that TM is a modulator of DC immunostimulatory properties and a novel candidate drug for the prevention of bronchial asthma in atopic patients.

  8. Growth and spectral properties of Tm:BaY2F8 crystals with different Tm3+ concentration

    NASA Astrophysics Data System (ADS)

    Liu, Wang; Li, Chun; Xu, Jialin; Zhou, Yao; Xie, Huishuang; Gao, Meiling; Yin, Ru; Zheng, Dongyang; Lin, Hai; Liu, Jinghe; Zeng, Fanming

    2016-01-01

    Tm3+:BaY2F8 (Tm:BYF) laser crystals with different doping concentrations were successfully grown by Czochralski method. The optimal growth parameters obtained are as follows: the pulling rate is 0.5 mm/h; the rotation speed is 5 rpm; the cooling rate is 10°C/h. Phase composition, absorption spectra, and fluorescence properties of crystals were studied by XRD and spectral methods. XRD analysis indicates that the crystal belongs to monoclinic system with the C2/ m space group. The lattice parameters were calculated and the anisotropy of the crystals was studied, confirming that the a axis is the best growth direction. The absorption peaks around 790 nm became larger with increase of Tm3+ concentration. The cross section of 15% Tm:BYF crystal around 791 nm is 9.47 × 10-21 cm2. The 10% Tm:BYF crystal has the strongest emission peak around 1879.6 nm with the FWHM of 79 nm and the emission cross-section of 2.13 × 10-21 cm2, which is favorable for the 1.88 μm laser output.

  9. Text mining of cancer-related information: review of current status and future directions.

    PubMed

    Spasić, Irena; Livsey, Jacqueline; Keane, John A; Nenadić, Goran

    2014-09-01

    This paper reviews the research literature on text mining (TM) with the aim to find out (1) which cancer domains have been the subject of TM efforts, (2) which knowledge resources can support TM of cancer-related information and (3) to what extent systems that rely on knowledge and computational methods can convert text data into useful clinical information. These questions were used to determine the current state of the art in this particular strand of TM and suggest future directions in TM development to support cancer research. A review of the research on TM of cancer-related information was carried out. A literature search was conducted on the Medline database as well as IEEE Xplore and ACM digital libraries to address the interdisciplinary nature of such research. The search results were supplemented with the literature identified through Google Scholar. A range of studies have proven the feasibility of TM for extracting structured information from clinical narratives such as those found in pathology or radiology reports. In this article, we provide a critical overview of the current state of the art for TM related to cancer. The review highlighted a strong bias towards symbolic methods, e.g. named entity recognition (NER) based on dictionary lookup and information extraction (IE) relying on pattern matching. The F-measure of NER ranges between 80% and 90%, while that of IE for simple tasks is in the high 90s. To further improve the performance, TM approaches need to deal effectively with idiosyncrasies of the clinical sublanguage such as non-standard abbreviations as well as a high degree of spelling and grammatical errors. This requires a shift from rule-based methods to machine learning following the success of similar trends in biological applications of TM. Machine learning approaches require large training datasets, but clinical narratives are not readily available for TM research due to privacy and confidentiality concerns. This issue remains the main bottleneck for progress in this area. In addition, there is a need for a comprehensive cancer ontology that would enable semantic representation of textual information found in narrative reports. Copyright © 2014 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  10. Relative radiometric calibration of LANDSAT TM reflective bands

    NASA Technical Reports Server (NTRS)

    Barker, J. L.

    1984-01-01

    A common scientific methodology and terminology is outlined for characterizing the radiometry of both TM sensors. The magnitude of the most significant sources of radiometric variability are discussed and methods are recommended for achieving the exceptional potential inherent in the radiometric precision and accuracy of the TM sensors.

  11. Flow cytometric detection method for DNA samples

    DOEpatents

    Nasarabadi, Shanavaz [Livermore, CA; Langlois, Richard G [Livermore, CA; Venkateswaran, Kodumudi S [Round Rock, TX

    2011-07-05

    Disclosed herein are two methods for rapid multiplex analysis to determine the presence and identity of target DNA sequences within a DNA sample. Both methods use reporting DNA sequences, e.g., modified conventional Taqman.RTM. probes, to combine multiplex PCR amplification with microsphere-based hybridization using flow cytometry means of detection. Real-time PCR detection can also be incorporated. The first method uses a cyanine dye, such as, Cy3.TM., as the reporter linked to the 5' end of a reporting DNA sequence. The second method positions a reporter dye, e.g., FAM.TM. on the 3' end of the reporting DNA sequence and a quencher dye, e.g., TAMRA.TM., on the 5' end.

  12. Kinematic effect of Nintendo WiiTM sports program exercise on obstacle gait in elderly women with falling risk

    PubMed Central

    Jung, Dae-In; Ko, Dae-Sik; Jeong, Mi-Ae

    2015-01-01

    [Purpose] This study evaluated the changes in balance ability and obstacle gait after lumbar stabilization exercise and Nintendo WiiTM Sports in elderly at risk for falls. [Subjects and Methods] Twenty-four elderly women with at risk for falls were randomly divided into the control, lumbar stabilization exercise, and Nintendo Wii Sports groups. Static balance was measured by the Berg Balance Scale and functional reach test, dynamic balance by the timed up-and-go test, and obstacle negotiation function by crossing velocity and maximum vertical heel clearance. [Results] Both the lumbar stabilization exercise and Nintendo Wii Sports groups showed significant improvements in obstacle negotiation function after the exercise compared to the control group. Berg Balance Scale and functional reach test scores were greater in the lumbar stabilization exercise group, while the timed up-and-go test time was significantly better in the Nintendo Wii Sports groups. [Conclusion] Lumbar stabilization exercises and Nintendo Wii Sports improve falling related balance and obstacle negotiation function in elderly women at risk for falls. PMID:26157228

  13. Kinematic effect of Nintendo Wii(TM) sports program exercise on obstacle gait in elderly women with falling risk.

    PubMed

    Jung, Dae-In; Ko, Dae-Sik; Jeong, Mi-Ae

    2015-05-01

    [Purpose] This study evaluated the changes in balance ability and obstacle gait after lumbar stabilization exercise and Nintendo Wii(TM) Sports in elderly at risk for falls. [Subjects and Methods] Twenty-four elderly women with at risk for falls were randomly divided into the control, lumbar stabilization exercise, and Nintendo Wii Sports groups. Static balance was measured by the Berg Balance Scale and functional reach test, dynamic balance by the timed up-and-go test, and obstacle negotiation function by crossing velocity and maximum vertical heel clearance. [Results] Both the lumbar stabilization exercise and Nintendo Wii Sports groups showed significant improvements in obstacle negotiation function after the exercise compared to the control group. Berg Balance Scale and functional reach test scores were greater in the lumbar stabilization exercise group, while the timed up-and-go test time was significantly better in the Nintendo Wii Sports groups. [Conclusion] Lumbar stabilization exercises and Nintendo Wii Sports improve falling related balance and obstacle negotiation function in elderly women at risk for falls.

  14. The use of radiation-induced graft polymerization for modification of polymer track membranes

    NASA Astrophysics Data System (ADS)

    Shtanko, N. I.; Kabanov, V. Ya.; Apel, P. Yu.; Yoshida, M.

    1999-05-01

    Track membranes (TM) made of poly(ethylene terephtalate) (PET) and polypropylene (PP) films have a number of peculiarities as compared with other ones. They have high mechanical strength at a low thickness, narrow pore size distribution, low content of extractables. However, TM have some disadvantages such as low chemical resistance in alkaline media (PET TM), the low water flow rate due to the hydrophobic nature of their surface. The use of radiation-induced graft polymerization makes it possible to improve the basic characteristics of TM. In this communication our results on the modification of PET and PP TM are presented. The modified membranes were prepared by radiation-induced graft polymerization from the liquid phase. Three methods of grafting were used: (a) the direct method in argon atmosphere; (b) the pre-irradiation of TM in air followed by grafting in argon atmosphere; (c) pre-irradiation in vacuum followed by grafting in vacuum without contacting oxygen. The aim of the work was to investigate some properties of TM modified by grafted poly(methylvinyl pyridine) (PMVP) and poly(N-isopropylacrylamide) (PNIPAAM). It was shown that the modification of TM with hydrophilic polymer results in the growth of the water flow rate. In the past few years many works have been devoted to the synthesis of new polymers - the so-called "intelligent" materials - such as PNIPAAM. However, it is very difficult to make thin membranes of this polymer. Recently, it has been proposed to manufacture composite membranes by grafting stimulus-responsive polymers onto TM. Following this principle, we prepared thermosensitive membranes by the radiation-induced graft polymerization of N-isopropylacrylamide (NIPAAM) onto PET TM. PET TM with the pore size of about 1 μm and pore density of 10 6 cm -2 were first inserted into a solution of NIPAAM containing inhibitor of homopolymerization (CuCl 2) and then exposed to the γ-rays from a 60Co source. The transport properties of the grafted TM were investigated. The permeation of water through the TM was controlled by temperature. The grafted TM exhibited almost the same transition temperature (about 33°C) as that of PNIPAAM.

  15. Prepsolv (TM): The optimum alternative to 1,1,1-trichloroethane and methyl ethyl ketone for hand-wipe cleaning of aerospace materials

    NASA Technical Reports Server (NTRS)

    Gallagher, R. Scott; Purvis, John A.; Moran, Wade W.

    1995-01-01

    Engineers at Hercules Aerospace, a rocket motor manufacturer in Utah, have worked closely with chemists at Glidco Organics to study the feasibility of using terpenes for zero-residue wipe cleaning. The result of this work is a technological breakthrough, in which the barrier to ultra-low non-volatile residue formation has been broken. After 2 years of development and testing, SCM Glidco Organics has announced the availability of Glidsafe(registered trademark) Prepsolv(TM): a state-of-the-art ultra-low residue terpene wipe cleaning agent that does not require rinsing. Prepsolv(TM) can successfully be used in simple hand-wipe cleaning processes without fear of leaving surface residues. Industry testing has confirmed that Prepsolv(TM) is not only highly effective, but can even be less expensive to use than traditional cleaning solvents like methyl chloroform. This paper addresses the features and benefits of Prepsolv(TM), and presents performance and material compatibility data that characterizes this unique cleaning agent. Since its commercialization, Hercules Aerospace has chosen Prepsolv(TM) as the optimum cleaning agent to replace ozone-depleting solvents in their weapons factory in Magna, UT. Likewise, Boeing has approved Prepsolv(TM) for cleaning components in the manufacture of commercial aircraft at their facilities in Seattle, WA and Wichita, KS. Additional approvals are forthcoming for this uniquely safe and effective solvent.

  16. Audiomagnetotelluric investigation of Snake Valley, eastern Nevada and western Utah

    USGS Publications Warehouse

    McPhee, Darcy K.; Pari, Keith; Baird, Frank

    2009-01-01

    As support for an exploratory well-drilling and hydraulic-testing program, AMT data were collected using a Geometrics Stratagem EH4 system along four profiles that extend roughly east-west from the southern Snake Range into Snake Valley. The profiles range from 3 to 5 kilometers in length, and station spacing was 200 to 400 meters. Two-dimensional inverse models were computed using the data from the transverse-electric (TE), transverse-magnetic (TM), and combined (TE+TM) mode using a conjugate gradient, finite-difference method. Interpretation of the 2-D AMT models defines several faults, some of which may influence ground-water flow in the basins, as well as identify underlying Paleozoic carbonate and clastic rocks and the thickness of basin-fill sediments. These AMT data and models, coupled with the geologic mapping and other surface geophysical methods, form the basis for identifying potential well sites and defining the subsurface structures and stratigraphy within Snake Valley.

  17. The effects of the Nintendo™ Wii Fit on gait, balance, and quality of life in individuals with incomplete spinal cord injury

    PubMed Central

    Feinn, Richard; Chui, Kevin; Cheng, M. Samuel

    2015-01-01

    Purpose To assess the effects of virtual reality using the NintendoTM Wii Fit on balance, gait, and quality of life in ambulatory individuals with incomplete spinal cord injury (iSCI). Relevance There is a need for continued research to support effective treatment techniques in individuals with iSCI to maximize each individual's potential functional performance. Subjects Five males with a mean age of 58.6 years who had an iSCI and were greater than one-year post injury. Methods An interrupted time series design with three pre-tests over three weeks, a post-test within one week of the intervention, and a four-week follow up. Outcome measures: gait speed, timed up and go (TUG), forward functional reach test (FFRT) and lateral functional reach test (LFRT), RAND SF-36. Intervention consisted of one-hour sessions with varied games using the Nintendo Wii Fit twice per week for seven weeks. Survey data was also collected at post-test. Results There were statistically significant changes found in gait speed and functional reach. The changes were also maintained at the four-week follow up post-test. Survey reports suggested improvements in balance, endurance, and mobility with daily tasks at home. Conclusion All subjects who participated in training with the NintendoTM Wii Fit demonstrated statistically significant improvements in gait speed and functional reach after seven weeks of training. Given the potential positive impact that the NintendoTM Wii Fit has on functional reach and gait speed in patients with iSCI, physical therapists may want to incorporate these activities as part of a rehabilitation program. PMID:25613853

  18. Energy transfer upconversion in Er3+-Tm3+ codoped sodium silicate glass

    NASA Astrophysics Data System (ADS)

    Kumar, Vinod; Pandey, Anurag; Ntwaeaborwa, O. M.; Swart, H. C.

    2018-04-01

    Er3+/Tm3+ doped and codoped Na2O-SiO2-ZnO (NSZO) glasses were prepared by the conventional melt-quenching method. The amorphous nature of the prepared glasses was confirmed by the X-ray diffraction analysis. The optical absorption spectrum displayed several peaks, which correspond to Er3+ and Tm3+ dopant ions embedded into the NSZO glass. Both dopants experienced upconversion emission under 980 nm excitation. Efficient energy transfer from Er3+ to Tm3+ was observed in the co-doped samples to enhance the near infrared emission of the Tm3+ ions.

  19. Comparison of Ambient and Atmospheric Pressure Ion Sources for Cystic Fibrosis Exhaled Breath Condensate Ion Mobility-Mass Spectrometry Metabolomics

    NASA Astrophysics Data System (ADS)

    Zang, Xiaoling; Pérez, José J.; Jones, Christina M.; Monge, María Eugenia; McCarty, Nael A.; Stecenko, Arlene A.; Fernández, Facundo M.

    2017-08-01

    Cystic fibrosis (CF) is an autosomal recessive disorder caused by mutations in the gene that encodes the cystic fibrosis transmembrane conductance regulator (CFTR) protein. The vast majority of the mortality is due to progressive lung disease. Targeted and untargeted CF breath metabolomics investigations via exhaled breath condensate (EBC) analyses have the potential to expose metabolic alterations associated with CF pathology and aid in assessing the effectiveness of CF therapies. Here, transmission-mode direct analysis in real time traveling wave ion mobility spectrometry time-of-flight mass spectrometry (TM-DART-TWIMS-TOF MS) was tested as a high-throughput alternative to conventional direct infusion (DI) electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) methods, and a critical comparison of the three ionization methods was conducted. EBC was chosen as the noninvasive surrogate for airway sampling over expectorated sputum as EBC can be collected in all CF subjects regardless of age and lung disease severity. When using pooled EBC collected from a healthy control, ESI detected the most metabolites, APCI a log order less, and TM-DART the least. TM-DART-TWIMS-TOF MS was used to profile metabolites in EBC samples from five healthy controls and four CF patients, finding that a panel of three discriminant EBC metabolites, some of which had been previously detected by other methods, differentiated these two classes with excellent cross-validated accuracy.

  20. Characterizing tissue microstructure using an ultrasound system-independent spatial autocorrelation function

    NASA Astrophysics Data System (ADS)

    Dong, Fang

    1999-09-01

    The research described in this dissertation is related to characterization of tissue microstructure using a system- independent spatial autocorrelation function (SAF). The function was determined using a reference phantom method, which employed a well-defined ``point- scatterer'' reference phantom to account for instrumental factors. The SAF's were estimated for several tissue-mimicking (TM) phantoms and fresh dog livers. Both phantom tests and in vitro dog liver measurements showed that the reference phantom method is relatively simple and fairly accurate, providing the bandwidth of the measurement system is sufficient for the size of the scatterer being involved in the scattering process. Implementation of this method in clinical scanner requires that distortions from patient's body wall be properly accounted for. The SAF's were estimated for two phantoms with body-wall-like distortions. The experimental results demonstrated that body wall distortions have little effect if echo data are acquired from a large scattering volume. One interesting application of the SAF is to form a ``scatterer size image''. The scatterer size image may help providing diagnostic tools for those diseases in which the tissue microstructure is different from the normal. Another method, the BSC method, utilizes information contained in the frequency dependence of the backscatter coefficient to estimate the scatterer size. The SAF technique produced accurate scatterer size images of homogeneous TM phantoms and the BSC method was capable of generating accurate size images for heterogeneous phantoms. In the scatterer size image of dog kidneys, the contrast-to-noise-ratio (CNR) between renal cortex and medulla was improved dramatically compared to the gray- scale image. The effect of nonlinear propagation was investigated by using a custom-designed phantom with overlaying TM fat layer. The results showed that the correlation length decreased when the transmitting power increased. The measurement results support the assumption that nonlinear propagation generates harmonic energies and causes underestimation of scatterer diameters. Nonlinear propagation can be further enhanced by those materials with high B/A value-a parameter which characterizes the degree of nonlinearity. Nine versions of TM fat and non-fat materials were measured for their B/A values using a new measurement technique, the ``simplified finite amplitude insertion substitution'' (SFAIS) method.

  1. Cervical Cancer Screening Preferences Among Trans-Masculine Individuals: Patient-Collected Human Papillomavirus Vaginal Swabs Versus Provider-Administered Pap Tests.

    PubMed

    McDowell, Michal; Pardee, Dana J; Peitzmeier, Sarah; Reisner, Sari L; Agénor, Madina; Alizaga, Natalie; Bernstein, Ida; Potter, Jennifer

    2017-08-01

    Trans-masculine (TM, i.e., persons who have a masculine spectrum gender identity, but were assigned female sex at birth) individuals face disparities in cervical cancer screening rates compared to cisgender women. Some unique barriers to screening in this population are specific to Pap tests. Introduction of self-collected frontal (i.e., vaginal) swabs for human papillomavirus (HPV) testing as a screening strategy may obviate these barriers. This study elucidates cervical cancer screening preferences among TM individuals. TM individuals participated in in-depth interviews (n = 31) and online surveys (n = 32) to explore perceptions and experiences regarding cervical cancer screening, including the acceptability of self-collected frontal HPV swabs for cervical cancer screening compared to provider-administered Pap tests. Provider-collected frontal HPV swab acceptability was also explored. Most TM individuals (94% in-person and 91% online participants) preferred either the self- or provider-collected frontal HPV swab to the Pap test. Participants perceived self- and provider-collected frontal HPV swabs to be less invasive, provoke less gender discordance, and promote a greater sense of agency compared to Pap tests. However, some participants expressed concern about HPV swab accuracy and, regarding the self-collected swab, discomfort about the need to engage with genitals they may not want to acknowledge. Individuals who reported positive provider relationships found Pap tests and provider-collected frontal swabs more acceptable than those who did not. Frontal HPV swabs have the potential to promote regular cervical cancer screening among TM individuals and to narrow screening disparities. Work is ongoing to establish swab accuracy and develop shared decision-making tools.

  2. The Temporalis Muscle Flap for Palate Reconstruction: Case Series and Review of the Literature

    PubMed Central

    Brennan, Tara; Tham, Tristan M.; Costantino, Peter

    2017-01-01

    Introduction  The temporalis myofascial (TM) is an important reconstructive flap in palate reconstruction. Past studies have shown the temporalis myofascial flap to be safe as well as effective. Free flap reconstruction of palate defects is also a popular method used by contemporary surgeons. We aim to reaffirm the temporalis myofascial flap as a viable alternative to free flaps for palate reconstruction. Objective  We report our results using the temporalis flap for palate reconstruction in one of the largest case series reported. Our literature review is the first to describe complication rates of palate reconstruction using the TM flap. Methods  Retrospective chart review and review of the literature. Results  Fifteen patients underwent palate reconstruction with the TM flap. There were no cases of facial nerve injury. Five (33%) of these patients underwent secondary cranioplasty to address temporal hollowing after the TM flap. Three out of fifteen (20%) had flap related complications. Fourteen (93%) of the palate defects were successfully reconstructed, with the remaining case pending a secondary procedure to close the defect. Ultimately, all of the flaps (100%) survived. Conclusion  The TM flap is a viable method of palate defect closure with a high defect closure rate and flap survival rate. TM flaps are versatile in repairing palate defects of all sizes, in all regions of the palate. Cosmetic deformity created from TM flap harvest may be addressed using cranioplasty implant placement, either primarily or during a second stage procedure. PMID:28680495

  3. mTM-align: a server for fast protein structure database search and multiple protein structure alignment.

    PubMed

    Dong, Runze; Pan, Shuo; Peng, Zhenling; Zhang, Yang; Yang, Jianyi

    2018-05-21

    With the rapid increase of the number of protein structures in the Protein Data Bank, it becomes urgent to develop algorithms for efficient protein structure comparisons. In this article, we present the mTM-align server, which consists of two closely related modules: one for structure database search and the other for multiple structure alignment. The database search is speeded up based on a heuristic algorithm and a hierarchical organization of the structures in the database. The multiple structure alignment is performed using the recently developed algorithm mTM-align. Benchmark tests demonstrate that our algorithms outperform other peering methods for both modules, in terms of speed and accuracy. One of the unique features for the server is the interplay between database search and multiple structure alignment. The server provides service not only for performing fast database search, but also for making accurate multiple structure alignment with the structures found by the search. For the database search, it takes about 2-5 min for a structure of a medium size (∼300 residues). For the multiple structure alignment, it takes a few seconds for ∼10 structures of medium sizes. The server is freely available at: http://yanglab.nankai.edu.cn/mTM-align/.

  4. a New Multi-Spectral Threshold Normalized Difference Water Index Mst-Ndwi Water Extraction Method - a Case Study in Yanhe Watershed

    NASA Astrophysics Data System (ADS)

    Zhou, Y.; Zhao, H.; Hao, H.; Wang, C.

    2018-05-01

    Accurate remote sensing water extraction is one of the primary tasks of watershed ecological environment study. Since the Yanhe water system has typical characteristics of a small water volume and narrow river channel, which leads to the difficulty for conventional water extraction methods such as Normalized Difference Water Index (NDWI). A new Multi-Spectral Threshold segmentation of the NDWI (MST-NDWI) water extraction method is proposed to achieve the accurate water extraction in Yanhe watershed. In the MST-NDWI method, the spectral characteristics of water bodies and typical backgrounds on the Landsat/TM images have been evaluated in Yanhe watershed. The multi-spectral thresholds (TM1, TM4, TM5) based on maximum-likelihood have been utilized before NDWI water extraction to realize segmentation for a division of built-up lands and small linear rivers. With the proposed method, a water map is extracted from the Landsat/TM images in 2010 in China. An accuracy assessment is conducted to compare the proposed method with the conventional water indexes such as NDWI, Modified NDWI (MNDWI), Enhanced Water Index (EWI), and Automated Water Extraction Index (AWEI). The result shows that the MST-NDWI method generates better water extraction accuracy in Yanhe watershed and can effectively diminish the confusing background objects compared to the conventional water indexes. The MST-NDWI method integrates NDWI and Multi-Spectral Threshold segmentation algorithms, with richer valuable information and remarkable results in accurate water extraction in Yanhe watershed.

  5. Landsat D Thematic Mapper image dimensionality reduction and geometric correction accuracy

    NASA Technical Reports Server (NTRS)

    Ford, G. E.

    1986-01-01

    To characterize and quantify the performance of the Landsat thematic mapper (TM), techniques for dimensionality reduction by linear transformation have been studied and evaluated and the accuracy of the correction of geometric errors in TM images analyzed. Theoretical evaluations and comparisons for existing methods for the design of linear transformation for dimensionality reduction are presented. These methods include the discrete Karhunen Loeve (KL) expansion, Multiple Discriminant Analysis (MDA), Thematic Mapper (TM)-Tasseled Cap Linear Transformation and Singular Value Decomposition (SVD). A unified approach to these design problems is presented in which each method involves optimizing an objective function with respect to the linear transformation matrix. From these studies, four modified methods are proposed. They are referred to as the Space Variant Linear Transformation, the KL Transform-MDA hybrid method, and the First and Second Version of the Weighted MDA method. The modifications involve the assignment of weights to classes to achieve improvements in the class conditional probability of error for classes with high weights. Experimental evaluations of the existing and proposed methods have been performed using the six reflective bands of the TM data. It is shown that in terms of probability of classification error and the percentage of the cumulative eigenvalues, the six reflective bands of the TM data require only a three dimensional feature space. It is shown experimentally as well that for the proposed methods, the classes with high weights have improvements in class conditional probability of error estimates as expected.

  6. Characterizing differences between MSCs and TM cells: Toward autologous stem cell therapies for the glaucomatous trabecular meshwork.

    PubMed

    Snider, Eric J; Vannatta, R Taylor; Schildmeyer, Lisa; Stamer, W Daniel; Ethier, C Ross

    2018-03-01

    Glaucoma, a leading cause of blindness, is characterized by an increase in intraocular pressure, which is largely determined by resistance to aqueous humour outflow through the trabecular meshwork (TM). In glaucoma, the cellularity of the TM is decreased, and, as a result, stem cell therapies for the TM represent a potential therapeutic option for restoring TM function and treating glaucoma patients. We here focus on adipose derived mesenchymal stem cells (MSCs) as a potential autologous cell source for TM regenerative medicine applications and describe characterization techniques at the messenger (reverse transcription-quantitative polymerase chain reaction), protein (western blotting, flow cytometry), and functional (contractility, phagocytosis) levels to distinguish MSCs from TM cells. We present a panel of 12 transcripts to allow: (a) suitable normalization of reverse transcription-quantitative polymerase chain reaction results across cell types and after exposure to potential differentiation stimuli; (b) distinguishing MSCs from TM cells; (c) distinguishing subtypes of TM cells; and (d) distinguishing TM cells from those in neighbouring tissue. At the protein level, dexamethasone induction of myocilin was a robust discriminating factor between MSCs and TM cells and was complemented by other protein markers. Finally, we show that contractility and phagocytosis differ between MSCs and TM cells. These methods are recommended for use in future differentiation studies to fully define if a functional TM-like phenotype is being achieved. Copyright © 2017 John Wiley & Sons, Ltd.

  7. Studies of tin-transition metal-carbon and tin-cobalt-transition metal-carbon negative electrode materials prepared by mechanical attrition

    NASA Astrophysics Data System (ADS)

    Ferguson, P. P.; Martine, M. L.; George, A. E.; Dahn, J. R.

    Samples of Sn 30TM 30C 40 and of Sn 30Co 15TM 15C 40, with TM = 3d transition metals, were prepared by vertical-axis attritor milling. The structure and performance of these samples were studied by X-ray diffraction (XRD) and by electrochemical testing. The XRD patterns of Sn 30TM 30C 40 show an amorphous-like diffraction pattern only for the sample with TM = Co. The other prepared samples show broadened Bragg peaks of their main starting material, along with an amorphous-like background, even after 32 h of milling. Samples with TM = Co and TM = Ni show stable differential capacity versus potential plots and stable cycling for at least 100 cycles with reversible capacities of 425 and 250 mAh g -1, respectively. All samples prepared with 15 at.% Co show good capacity retention for at least 100 cycles ranging from 270 mAh g -1 for samples with TM = Ni to 500 mAh g -1 for samples with TM = Ti. The differential capacity versus potential plots for all the prepared Sn 30Co 15TM 15C 40 samples show similar structure to that of Sn 30Co 30C 40 except when TM = Cu. This shows the possibility of preparing tin-based negative electrode materials using a combination of cobalt and TM, especially if one looks to reduce the cobalt content.

  8. Freeze-thaw decellularization of the trabecular meshwork in an ex vivo eye perfusion model

    PubMed Central

    Dang, Yalong; Waxman, Susannah; Wang, Chao; Jensen, Adrianna; Loewen, Ralitsa T.; Bilonick, Richard A.

    2017-01-01

    Objective The trabecular meshwork (TM) is the primary substrate of outflow resistance in glaucomatous eyes. Repopulating diseased TM with fresh, functional TM cells might be a viable therapeutic approach. Decellularized TM scaffolds have previously been produced by ablating cells with suicide gene therapy or saponin, which risks incomplete cell removal or dissolution of the extracellular matrix, respectively. We hypothesized that improved trabecular meshwork cell ablation would result from freeze-thaw cycles compared to chemical treatment. Materials and Methods We obtained 24 porcine eyes from a local abattoir, dissected and mounted them in an anterior segment perfusion within two hours of sacrifice. Intraocular pressure (IOP) was recorded continuously by a pressure transducer system. After 72 h of IOP stabilization, eight eyes were assigned to freeze-thaw (F) ablation (−80 °C × 2), to 0.02% saponin (S) treatment, or the control group (C), respectively. The TM was transduced with an eGFP expressing feline immunodeficiency viral (FIV) vector and tracked via fluorescent microscopy to confirm ablation. Following treatment, the eyes were perfused with standard tissue culture media for 180 h. TM histology was assessed by hematoxylin and eosin staining. TM viability was evaluated by a calcein AM/propidium iodide (PI) assay. The TM extracellular matrix was stained with Picro Sirius Red. We measured IOP and modeled it with a linear mixed effects model using a B-spline function of time with five degrees of freedom. Results F and S experienced a similar IOP reduction of 30% from baseline (P = 0.64). IOP reduction of about 30% occurred in F within 24 h and in S within 48 h. Live visualization of eGFP demonstrated that F conferred a complete ablation of all TM cells and only a partial ablation in S. Histological analysis and Picro Sirius staining confirmed that no TM cells survived in F while the extracellular matrix remained. The viability assay showed very low PI and no calcein staining in F in contrast to many PI-labeled, dead TM cells and calcein-labeled viable TM cells in S. Conclusion We developed a rapid TM ablation method that uses cyclic freezing that is free of biological or chemical agents and able to produce a decellularized TM scaffold with preserved TM extracellular matrix in an organotypic perfusion culture. PMID:28828244

  9. The Determinants of Traditional Medicine Use in Northern Tanzania: A Mixed-Methods Study

    PubMed Central

    Stanifer, John W.; Patel, Uptal D.; Karia, Francis; Thielman, Nathan; Maro, Venance; Shimbi, Dionis; Kilaweh, Humphrey; Lazaro, Matayo; Matemu, Oliver; Omolo, Justin; Boyd, David

    2015-01-01

    Introduction Traditional medicines are an important part of healthcare in sub-Saharan Africa, and building successful disease treatment programs that are sensitive to traditional medicine practices will require an understanding of their current use and roles, including from a biomedical perspective. Therefore, we conducted a mixed-method study in Northern Tanzania in order to characterize the extent of and reasons for the use of traditional medicines among the general population so that we can better inform public health efforts in the region. Methods Between December 2013 and June 2014 in Kilimanjaro, Tanzania, we conducted 5 focus group discussions and 27 in-depth interviews of key informants. The data from these sessions were analyzed using an inductive framework method with cultural insider-outsider coding. From these results, we developed a structured survey designed to test different aspects of traditional medicine use and administered it to a random sample of 655 adults from the community. The results were triangulated to explore converging and diverging themes. Results Most structured survey participants (68%) reported knowing someone who frequently used traditional medicines, and the majority (56%) reported using them themselves in the previous year. The most common uses were for symptomatic ailments (42%), chronic diseases (15%), reproductive problems (11%), and malaria/febrile illnesses (11%). We identified five major determinants for traditional medicine use in Northern Tanzania: biomedical healthcare delivery, credibility of traditional practices, strong cultural identities, individual health status, and disease understanding. Conclusions In order to better formulate effective local disease management programs that are sensitive to TM practices, we described the determinants of TM use. Additionally, we found TM use to be high in Northern Tanzania and that its use is not limited to lower-income areas or rural settings. After symptomatic ailments, chronic diseases were reported as the most common reason for TM use which may be particularly important in Northern Tanzania where non-communicable diseases are a rapidly growing burden. PMID:25848762

  10. The free-fall mode experiment on LISA Pathfinder: first results

    NASA Astrophysics Data System (ADS)

    Giusteri, Roberta; LPF Collaboration

    2017-05-01

    The LISA Pathfinder space mission is testing the critical experimental challenge for LISA by measuring the differential acceleration between two free-falling test masses inside a single co-orbiting spacecraft at a level of sub-femto-g for frequencies down to 0.1mHz. In LPF it is necessary that one test mass (TM) is electrostatically forced to follow the orbit of the other TM. This force represents a noise source in differential acceleration at frequencies below 1mHz. The free-fall mode experiment has been performed in order to reduce this source of noise: the actuation is limited to short impulses on one TM, so that it is in free fall between two successive kicks, while the other TM is drag-free. The free-fall mode thus provides a different technique for measuring the differential TM acceleration without the added force noise and calibration issues introduced by the actuator. Data analysis challenge is related to the presence of the kicks: they represent a high-noise contribution and need to be removed, thus leaving short gaps in data. This article presents preliminary data of the LPF free-fall measurement campaign and describes the three data analysis techniques developed to mitigate the presence of gaps.

  11. Trimeric transmembrane domain interactions in paramyxovirus fusion proteins: roles in protein folding, stability, and function.

    PubMed

    Smith, Everett Clinton; Smith, Stacy E; Carter, James R; Webb, Stacy R; Gibson, Kathleen M; Hellman, Lance M; Fried, Michael G; Dutch, Rebecca Ellis

    2013-12-13

    Paramyxovirus fusion (F) proteins promote membrane fusion between the viral envelope and host cell membranes, a critical early step in viral infection. Although mutational analyses have indicated that transmembrane (TM) domain residues can affect folding or function of viral fusion proteins, direct analysis of TM-TM interactions has proved challenging. To directly assess TM interactions, the oligomeric state of purified chimeric proteins containing the Staphylococcal nuclease (SN) protein linked to the TM segments from three paramyxovirus F proteins was analyzed by sedimentation equilibrium analysis in detergent and buffer conditions that allowed density matching. A monomer-trimer equilibrium best fit was found for all three SN-TM constructs tested, and similar fits were obtained with peptides corresponding to just the TM region of two different paramyxovirus F proteins. These findings demonstrate for the first time that class I viral fusion protein TM domains can self-associate as trimeric complexes in the absence of the rest of the protein. Glycine residues have been implicated in TM helix interactions, so the effect of mutations at Hendra F Gly-508 was assessed in the context of the whole F protein. Mutations G508I or G508L resulted in decreased cell surface expression of the fusogenic form, consistent with decreased stability of the prefusion form of the protein. Sedimentation equilibrium analysis of TM domains containing these mutations gave higher relative association constants, suggesting altered TM-TM interactions. Overall, these results suggest that trimeric TM interactions are important driving forces for protein folding, stability and membrane fusion promotion.

  12. Trimeric Transmembrane Domain Interactions in Paramyxovirus Fusion Proteins

    PubMed Central

    Smith, Everett Clinton; Smith, Stacy E.; Carter, James R.; Webb, Stacy R.; Gibson, Kathleen M.; Hellman, Lance M.; Fried, Michael G.; Dutch, Rebecca Ellis

    2013-01-01

    Paramyxovirus fusion (F) proteins promote membrane fusion between the viral envelope and host cell membranes, a critical early step in viral infection. Although mutational analyses have indicated that transmembrane (TM) domain residues can affect folding or function of viral fusion proteins, direct analysis of TM-TM interactions has proved challenging. To directly assess TM interactions, the oligomeric state of purified chimeric proteins containing the Staphylococcal nuclease (SN) protein linked to the TM segments from three paramyxovirus F proteins was analyzed by sedimentation equilibrium analysis in detergent and buffer conditions that allowed density matching. A monomer-trimer equilibrium best fit was found for all three SN-TM constructs tested, and similar fits were obtained with peptides corresponding to just the TM region of two different paramyxovirus F proteins. These findings demonstrate for the first time that class I viral fusion protein TM domains can self-associate as trimeric complexes in the absence of the rest of the protein. Glycine residues have been implicated in TM helix interactions, so the effect of mutations at Hendra F Gly-508 was assessed in the context of the whole F protein. Mutations G508I or G508L resulted in decreased cell surface expression of the fusogenic form, consistent with decreased stability of the prefusion form of the protein. Sedimentation equilibrium analysis of TM domains containing these mutations gave higher relative association constants, suggesting altered TM-TM interactions. Overall, these results suggest that trimeric TM interactions are important driving forces for protein folding, stability and membrane fusion promotion. PMID:24178297

  13. Comparison of Molecular and Phenotypic Methods for the Detection and Characterization of Carbapenem Resistant Enterobacteriaceae.

    PubMed

    Somily, Ali M; Garaween, Ghada A; Abukhalid, Norah; Absar, Muhammad M; Senok, Abiola C

    2016-03-01

    In recent years, there has been a rapid dissemination of carbapenem resistant Enterobacteriaceae (CRE). This study aimed to compare phenotypic and molecular methods for detection and characterization of CRE isolates at a large tertiary care hospital in Saudi Arabia. This study was carried out between January 2011 and November 2013 at the King Khalid University Hospital (KKUH) in Saudi Arabia. Determination of presence of extended-spectrum beta-lactamases (ESBL) and carbapenem resistance was in accordance with Clinical and Laboratory Standards Institute (CLSI) guidelines. Phenotypic classification was done by the MASTDISCS(TM) ID inhibitor combination disk method. Genotypic characterization of ESBL and carbapenemase genes was performed by the Check-MDR CT102. Diversilab rep-PCR was used for the determination of clonal relationship. Of the 883 ESBL-positive Enterobacteriaceae detected during the study period, 14 (1.6%) isolates were carbapenem resistant. Both the molecular genotypic characterization and phenotypic testing were in agreement in the detection of all 8 metalo-beta-lactamases (MBL) producing isolates. Of these 8 MBL-producers, 5 were positive for blaNDM gene and 3 were positive for blaVIM gene. Molecular method identified additional blaOXA gene isolates while MASTDISCS(TM) ID detected one AmpC producer isolate. Both methods agreed in identifying 2 carbapenem resistant isolates which were negative for carbapenemase genes. Diversilab rep-PCR analysis of the 9 Klebsiella pneumoniae isolates revealed polyclonal distribution into eight clusters. MASTDISCS(TM) ID is a reliable simple cheap phenotypic method for detection of majority of carbapenemase genes with the exception of the blaOXA gene. We recommend to use such method in the clinical laboratory.

  14. Frequency-Response Identification of XV-15 Tilt-Rotor Aircraft Dynamics

    DTIC Science & Technology

    1987-05-01

    Sciences, Vol. 14, No. 9, Sept. 1947, pp. 493-499. 1 163 8. Greenberg , Harry, "A Survey of Methods for Determining Stabil- ity Parameters of an Airplane...Sweep Testing Technique using a Bell 214-ST Helicopter," NASA TM-89422, 1987. 21. Hilbert , K. B., Lebacqz, J. V., and Hindson, W. S., "Flight

  15. Progress in adapting k-NN methods for forest mapping and estimation using the new annual Forest Inventory and Analysis data

    Treesearch

    Reija Haapanen; Kimmo Lehtinen; Jukka Miettinen; Marvin E. Bauer; Alan R. Ek

    2002-01-01

    The k-nearest neighbor (k-NN) method has been undergoing development and testing for applications with USDA Forest Service Forest Inventory and Analysis (FIA) data in Minnesota since 1997. Research began using the 1987-1990 FIA inventory of the state, the then standard 10-point cluster plots, and Landsat TM imagery. In the past year, research has moved to examine...

  16. Performance testing of asphalt concrete containing crumb rubber modifier and warm mix additives

    NASA Astrophysics Data System (ADS)

    Ikpugha, Omo John

    Utilisation of scrap tire has been achieved through the production of crumb rubber modified binders and rubberised asphalt concrete. Terminal and field blended asphalt rubbers have been developed through the wet process to incorporate crumb rubber into the asphalt binder. Warm mix asphalt technologies have been developed to curb the problem associated with the processing and production of such crumb rubber modified binders. Also the lowered production and compaction temperatures associated with warm mix additives suggests the possibility of moisture retention in the mix, which can lead to moisture damage. Conventional moisture sensitivity tests have not effectively discriminated good and poor mixes, due to the difficulty of simulating field moisture damage mechanisms. This study was carried out to investigate performance properties of crumb rubber modified asphalt concrete, using commercial warm mix asphalt technology. Commonly utilised asphalt mixtures in North America such as dense graded and stone mastic asphalt were used in this study. Uniaxial Cyclic Compression Testing (UCCT) was used to measure permanent deformation at high temperatures. Indirect Tensile Testing (IDT) was used to investigate low temperature performance. Moisture Induced Sensitivity Testing (MiST) was proposed to be an effective method for detecting the susceptibility of asphalt mixtures to moisture damage, as it incorporates major field stripping mechanisms. Sonnewarm(TM), Sasobit(TM) and Evotherm(TM) additives improved the resistance to permanent deformation of dense graded mixes at a loading rate of 0.5 percent by weight of the binder. Polymer modified mixtures showed superior resistance to permanent deformation compared to asphalt rubber in all mix types. Rediset(TM) WMX improves low temperature properties of dense graded mixes at 0.5 percent loading on the asphalt cement. Rediset LQ and Rediset WMX showed good anti stripping properties at 0.5 percent loading on the asphalt cement. The American Association of State Highway and Transportation Official's Mechanistic-Empirical Pavement Design Guide (AASHTO MEPDG) software was used to predict long term low temperature performance of the mixtures in various areas of Ontario. Sasobit, Rediset LQ and Rediset WMX gave good 15 years prediction with stone mastic asphalt mixtures but the performance of dense graded mixtures was less satisfactory.

  17. [Detection of circulating tumor cells in patients with hepatocellular carcinoma].

    PubMed

    Mu, Hong; Lin, Kaixuan; Zhao, Hong; Li, Cong; Sun, Yulin; Cai, Jianqiang; Zhao, Xiaohang

    2014-04-01

    To explore the detection efficiency of circulating tumor cells (CTCs) in patients with hepatocellular carcinoma (HCC). Immunomagnetic negative enrichment by nanometer magnetic beads and label-free capture with Captor(TM) system were used to isolate and enrich CTCs from peripheral blood of HCC patients, and epithelial and HCC markers were applied to identify CTCs by immunofluorescence staining. CTCs were detected in 50 HCC patients before and after hepatectomy to test the method for isolation, enrichment and identification. The dynamic changes of pre- and post-operative CTCs' numbers were compared. The clinical data were analyzed using SPSS 19.0 software. Negative enrichment methods by nanometer magnetic beads and label-free capture using Captor(TM) system were both suitable for CTCs isolation and enrichment in HCC patients. The positive detection rate of CTCs in HCC patients via negative enrichment was 96.0% (48/50), the preoperative median number of CTCs was 16 per 7.5 ml blood, and the postoperative median number was 17 per 7.5 ml blood. Both negative enrichment and Captor(TM) system are suitable for isolation and enrichment of CTCs in HCC patients. There is a significant difference in the numbers of CTCs before and after operation, and dynamic detection of CTCs will provide helpful prognostic information for HCC patients in clinics.

  18. Label-free imaging of trabecular meshwork cells using Coherent Anti-Stokes Raman Scattering (CARS) microscopy

    PubMed Central

    Lei, Tim C.; Ammar, David A.; Masihzadeh, Omid; Gibson, Emily A.

    2011-01-01

    Purpose To image the human trabecular meshwork (TM) using a non-invasive, non-destructive technique without the application of exogenous label. Methods Flat-mounted TM samples from a human cadaver eye were imaged using two nonlinear optical techniques: coherent anti-Stokes Raman scattering (CARS) and two-photon autofluorescence (TPAF). In TPAF, two optical photons are simultaneously absorbed and excite molecules in the sample that then emit a higher energy photon. The signal is predominately from collagen and elastin. The CARS technique uses two laser frequencies to specifically excite carbon-hydrogen bonds, allowing the visualization of lipid-rich cell membranes. Multiple images were taken along an axis perpendicular to the surface of the TM for subsequent analysis. Results Analysis of multiple TPAF images of the TM reveals the characteristic overlapping bundles of collagen of various sizes. Simultaneous CARS imaging revealed elliptical structures of ~7×10 µm in diameter populating the meshwork which were consistent with TM cells. Irregularly shaped objects of ~4 µm diameter appeared in both the TPAF and CARS channels, and are consistent with melanin granules. Conclusions CARS techniques were successful in imaging live TM cells in freshly isolated human TM samples. Similar images have been obtained with standard histological techniques, however the method described here has the advantage of being performed on unprocessed, unfixed tissue free from the potential distortions of the fine tissue morphology that can occur due to infusion of fixatives and treatment with alcohols. CARS imaging of the TM represents a new avenue for exploring details of aqueous outflow and TM cell physiology. PMID:22025898

  19. Development of LaRC (TM): IA thermoplastic polyimide coated aerospace wiring

    NASA Technical Reports Server (NTRS)

    Keating, Jack

    1995-01-01

    NASA Langley has invented LaRC(exp TM) IA and IAX which are thermoplastic polyimides with good melting, thermal and chemical resistance properties. It was the objective of this contract to prepare and extrude LaRC (exp TM) polyimide onto aircraft wire and evaluate the polymers performance in this critical application. Based on rheology and chemical resistance studies at Imitec, LaRC (exp TM) IAX melts readily in an extruder, facilitating the manufacture of thin wall coatings. The polyimide does not corode the extruder, develop gel particles nor advance in viscosity. The insulated wire was tested according to MiL-W-22759E test specifications. The resulting wire coated with LaRC (exp TM) IAX displayed exceptional properties: surface resistance, non blocking, non burning, hot fluid resistance, impulse dielectric, insulation resistance, low temperature flexibility, thermal aging, wire weight, dimensions, negligible high temperature shrinkage and stripability. The light weight and other properties merit its application in satellites, missiles and aircraft applications. The extruded IAX results in a polyimide aircraft insulation without seams, outstanding moisture resistance, continuous lengths and abrasion resistance.

  20. SYBR safeTM efficiently replaces ethidium bromide in Aspergillus fumigatus gene disruption.

    PubMed

    Canela, H M S; Takami, L A; Ferreira, M E S

    2017-02-08

    Invasive aspergillosis is a disease responsible for high mortality rates, caused mainly by Aspergillus fumigatus. The available drugs are limited and this disease continues to occur at an unacceptable frequency. Gene disruption is essential in the search for new drug targets. An efficient protocol for A. fumigatus gene disruption was described but it requires ethidium bromide, a genotoxic agent, for DNA staining. Therefore, the present study tested SYBR safe TM , a non-genotoxic DNA stain, in A. fumigatus gene disruption protocol. The chosen gene was cipC, which has already been disrupted successfully in our laboratory. A deletion cassette was constructed in Saccharomyces cerevisiae and used in A. fumigatus transformation. There was no statistical difference between the tested DNA stains. The success rate of S. cerevisiae transformation was 63.3% for ethidium bromide and 70% for SYBR safe TM . For A. fumigatus gene disruption, the success rate for ethidium bromide was 100 and 97% for SYBR safe TM . In conclusion, SYBR safe TM efficiently replaced ethidium bromide, making this dye a safe and efficient alternative for DNA staining in A. fumigatus gene disruption.

  1. An experimental investigation of using carbon foam-PCM-MWCNTs composite materials for thermal management of electronic devices under pulsed power modes

    NASA Astrophysics Data System (ADS)

    Alshaer, W. G.; Rady, M. A.; Nada, S. A.; Palomo Del Barrio, Elena; Sommier, Alain

    2017-02-01

    The present article reports on a detailed experimental investigation of using carbon foam-PCM-MWCNTs composite materials for thermal management (TM) of electronic devices subjected to pulsed power. The TM module was fabricated by infiltrating paraffin wax (RT65) as a phase change material (PCM) and multi walled carbon nanotubes (MWCNTs) as a thermal conductivity enhancer in a carbon foam as a base structure. Two carbon foam materials of low and high values of thermal conductivities, CF20 and KL1-250 (3.1 and 40 W/m K), were tested as a base structure for the TM modules. Tests were conducted at different power intensities and power cycling/loading modes. Results showed that for all power varying modes and all carbon foams, the infiltration of RT65 into carbon foam reduces the temperature of TM module and results in damping the temperature spikes height. Infiltration of MWCNTS into RT65 further improves the effectiveness of TM module. Temperature damping was more pronounced in stand-alone pulsed power cycles as compared to pulsed power spikes modes. The effectiveness of inclusion of RT65 and RT65/MWCNTs in damping the temperature spikes height is remarkable in TM modules based on KL1-250 as compared to CF-20.

  2. Wheat yield estimation at the farm level using TM Landsat and agrometeorological data

    NASA Technical Reports Server (NTRS)

    Rudorff, B. F. T.; Batista, G. T.

    1991-01-01

    A model for estimating wheat yields on the farm level was developed, that integrates the Landsat TM data and agrometeorological information. Results obtained for a test site in southern Brasil for years of 1986 and 1987 show that the vegetation index derived from Landsat TM could account for the 60 to 40 percent wheat-yield variability observed between the two crop years. Compared to results using either the Landsat TM vegetation index or the agrometeorological data alone, the joint use of both types of data in a single model yielded a significant improvement.

  3. The Role of Stanford Achievement Test 10[TM] Subtests in Sixth Grade as a Predictor of Success on ACT's Eighth Grade Explore Exam[TM

    ERIC Educational Resources Information Center

    Potts, Jeffrey D.

    2011-01-01

    The purpose of this study was to determine if there was a predictive correlation between a specific sixth grade achievement test known as the Stanford Achievement Test 10 and the eighth grade college readiness assessment instrument known as the Explore Exam for a group of North Texas students. Following an assessment during sixth grade, via the…

  4. ANTHROPOMORPHIC PHANTOMS FOR ASSESSMENT OF STRAIN IMAGING METHODS INVOLVING SALINE-INFUSED SONOHYSTEROGRAPHY

    PubMed Central

    Hobson, Maritza A.; Madsen, Ernest L.; Frank, Gary R.; Jiang, Jingfeng; Shi, Hairong; Hall, Timothy J.; Varghese, Tomy

    2008-01-01

    Two anthropomorphic uterine phantoms were developed which allow assessment and comparison of strain imaging systems adapted for use with saline-infused sonohysterography (SIS). Tissue-mimicking (TM) materials consist of dispersions of safflower oil in gelatin. TM fibroids are stiffer than the TM myometrium/cervix and TM polyps are softer. The first uterine phantom has 3-mm diameter TM fibroids randomly distributed in TM myometrium. The second uterine phantom has a 5-mm and an 8-mm spherical TM fibroid in addition to a 5-mm spherical and a 12.5-mm long (medicine-capsule-shaped) TM endometrial polyp protruding into the endometrial cavity; also, a 10-mm spherical TM fibroid projects from the serosal surface. Strain images using the first phantom show the stiffer 3-mm TM fibroids in the myometrium. Results from the second uterine phantom show that, as expected, parts of inclusions projecting into the uterine cavity will appear very stiff, whether they are stiff or soft. Results from both phantoms show that even though there is a five-fold difference in the Young’s moduli values, there is not a significant difference in the strain in the transition from the TM myometrium to the TM fat. These phantoms allow for realistic comparison and evolution of SIS strain imaging techniques and can aid clinical personnel to develop skills for SIS strain imaging. PMID:18514999

  5. Pilot Testing "Okay with Asthma"[TM]: An Online Asthma Intervention for School-Age Children

    ERIC Educational Resources Information Center

    Wyatt, Tami H.; Hauenstein, Emily J.

    2008-01-01

    Asthma is the leading cause of missed school days despite advancements in asthma treatment. This may be, in part, due to a lack of understanding about asthma. "Okay With Asthma"[TM], an online story with psychosocial management strategies for school-age children, was pilot tested to measure its effect on asthma knowledge and attitude. The online…

  6. TOEFL iBT Speaking Test Scores as Indicators of Oral Communicative Language Proficiency

    ERIC Educational Resources Information Center

    Bridgeman, Brent; Powers, Donald; Stone, Elizabeth; Mollaun, Pamela

    2012-01-01

    Scores assigned by trained raters and by an automated scoring system (SpeechRater[TM]) on the speaking section of the TOEFL iBT[TM] were validated against a communicative competence criterion. Specifically, a sample of 555 undergraduate students listened to speech samples from 184 examinees who took the Test of English as a Foreign Language…

  7. Luminescence mechanism and energy transfer in doubly-doped BaY2F8:Tm,Nd VUV scintillator

    NASA Astrophysics Data System (ADS)

    Pejchal, J.; Nikl, M.; Moretti, F.; Vedda, A.; Fukuda, K.; Kawaguchi, N.; Yanagida, T.; Yokota, Y.; Yoshikawa, A.

    2010-11-01

    Doubly-doped BaY2F8:Tm,Nd scintillation crystals were grown by modified micro-pulling-down method. Nd co-doping was chosen to enhance the energy transfer from the host lattice to the Nd3+ luminescence center via the 5d-levels of Tm3+, due to the overlap of Tm3+ 5d-4f emission spectrum with the Nd3+ 4f-5d absorption. The energy transfer was clearly evidenced in the BaY2F8:Tm,Nd. This process is not complicated by an energy migration to killer centers and/or cross-relaxation. The radioluminescence process is complicated by an energy transfer from the host lattice exciton states to the lower f-levels of Tm3+ ion.

  8. Ab Initio Protein Structure Prediction Using Chunk-TASSER

    PubMed Central

    Zhou, Hongyi; Skolnick, Jeffrey

    2007-01-01

    We have developed an ab initio protein structure prediction method called chunk-TASSER that uses ab initio folded supersecondary structure chunks of a given target as well as threading templates for obtaining contact potentials and distance restraints. The predicted chunks, selected on the basis of a new fragment comparison method, are folded by a fragment insertion method. Full-length models are built and refined by the TASSER methodology, which searches conformational space via parallel hyperbolic Monte Carlo. We employ an optimized reduced force field that includes knowledge-based statistical potentials and restraints derived from the chunks as well as threading templates. The method is tested on a dataset of 425 hard target proteins ≤250 amino acids in length. The average TM-scores of the best of top five models per target are 0.266, 0.336, and 0.362 by the threading algorithm SP3, original TASSER and chunk-TASSER, respectively. For a subset of 80 proteins with predicted α-helix content ≥50%, these averages are 0.284, 0.356, and 0.403, respectively. The percentages of proteins with the best of top five models having TM-score ≥0.4 (a statistically significant threshold for structural similarity) are 3.76, 20.94, and 28.94% by SP3, TASSER, and chunk-TASSER, respectively, overall, while for the subset of 80 predominantly helical proteins, these percentages are 2.50, 23.75, and 41.25%. Thus, chunk-TASSER shows a significant improvement over TASSER for modeling hard targets where no good template can be identified. We also tested chunk-TASSER on 21 medium/hard targets <200 amino-acids-long from CASP7. Chunk-TASSER is ∼11% (10%) better than TASSER for the total TM-score of the first (best of top five) models. Chunk-TASSER is fully automated and can be used in proteome scale protein structure prediction. PMID:17496016

  9. Laboratory test for ice adhesion strength using commercial instrumentation.

    PubMed

    Wang, Chenyu; Zhang, Wei; Siva, Adarsh; Tiea, Daniel; Wynne, Kenneth J

    2014-01-21

    A laboratory test method for evaluating ice adhesion has been developed employing a commercially available instrument normally used for dynamic mechanical analysis (TA RSA-III). This is the first laboratory ice adhesion test that does not require a custom-built apparatus. The upper grip range of ∼10 mm is an enabling feature that is essential for the test. The method involves removal of an ice cylinder from a polymer coating with a probe and the determination of peak removal force (Ps). To validate the test method, the strength of ice adhesion was determined for a prototypical glassy polymer, poly(methyl methacrylate). The distance of the probe from the PMMA surface has been identified as a critical variable for Ps. The new test provides a readily available platform for investigating fundamental surface characteristics affecting ice adhesion. In addition to the ice release test, PMMA coatings were characterized using DSC, DCA, and TM-AFM.

  10. Application of 'Six Sigma{sup TM}' and 'Design of Experiment' for Cementation - Recipe Development for Evaporator Concentrate for NPP Ling AO, Phase II (China) - 12555

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fehrmann, Henning; Perdue, Robert

    2012-07-01

    Cementation of radioactive waste is a common technology. The waste is mixed with cement and water and forms a stable, solid block. The physical properties like compression strength or low leach ability depends strongly on the cement recipe. Due to the fact that this waste cement mixture has to fulfill special requirements, a recipe development is necessary. The Six Sigma{sup TM}' DMAIC methodology, together with the Design of experiment (DoE) approach, was employed to optimize the process of a recipe development for cementation at the Ling Ao nuclear power plant (NPP) in China. The DMAIC offers a structured, systematical andmore » traceable process to derive test parameters. The DoE test plans and statistical analysis is efficient regarding the amount of test runs and the benefit gain by getting a transfer function. A transfer function enables simulation which is useful to optimize the later process and being responsive to changes. The DoE method was successfully applied for developing a cementation recipe for both evaporator concentrate and resin waste in the plant. The key input parameters were determined, evaluated and the control of these parameters were included into the design. The applied Six Sigma{sup TM} tools can help to organize the thinking during the engineering process. Data are organized and clearly presented. Various variables can be limited to the most important ones. The Six Sigma{sup TM} tools help to make the thinking and decision process trace able. The tools can help to make data driven decisions (e.g. C and E Matrix). But the tools are not the only golden way. Results from scoring tools like the C and E Matrix need close review before using them. The DoE is an effective tool for generating test plans. DoE can be used with a small number of tests runs, but gives a valuable result from an engineering perspective in terms of a transfer function. The DoE prediction results, however, are only valid in the tested area. So a careful selection of input parameter and their limits for setting up a DoE is very important. An extrapolation of results is not recommended because the results are not reliable out of the tested area. (authors)« less

  11. Electrocardiographic abnormalities and arrhythmic risk markers in adult patients with beta thalassemia major.

    PubMed

    Kolios, Marios; Korantzopoulos, Panagiotis; Vlahos, Antonios P; Kapsali, Eleni; Briasoulis, Evangelos; Goudevenos, John A

    2016-10-15

    There seems to be a significant arrhythmia burden in β-thalassemia major (TM) patients without overt cardiomyopathy. Apart from conventional electrocardiographic (ECG) and arrhythmic risk markers we studied novel markers of ventricular repolarization and autonomic imbalance both at rest and after exercise testing. We studied 47 adult TM patients without systolic heart failure and 47 age and sex-matched healthy control subjects. The median age of the studied population was 36 [32-43] years, 57% men. Baseline demographic and clinical characteristics were recorded while 12-lead electrocardiograms, 24-hour ECG Holter recordings, and treadmill exercise stress tests were analyzed. TM patients exhibited increased QTc intervals in both 12-lead ECG recordings and in 24-hour Holter recordings. In addition, they had increased indexes of ventricular repolarization heterogeneity such as QT dispersion, and T peak-to-end/QT ratios. Furthermore, TM patients had decreased indexes of heart rate variability while the heart rate recovery after exercise was significantly attenuated compared to controls. Also, they had increased P wave and QRS duration while the QRS fragmentation was very prevalent. Finally, premature atrial extrasystoles and paroxysmal atrial fibrillation episodes were more frequent in TM patients. TM patients with preserved left ventricular systolic function have several ECG abnormalities including alterations in ventricular depolarization and repolarization. Also, cardiac autonomic dysfunction is evident in 24-hour ECG monitoring as well as in the recovery phase after exercise testing. The prognostic value of specific arrhythmic risk indexes in this setting remains to be elucidated. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. Comparison of a novel high-power blue diode laser (λ=442 nm) with Ho:YAG (λ=2100 nm), Tm fiber (λ=1940 nm), and KTP (λ=532 nm) lasers for soft tissue ablation

    NASA Astrophysics Data System (ADS)

    Vinnichenko, Victoriya; Kovalenko, Anastasiya; Arkhipova, Valeriya; Yaroslavsky, Ilya; Altshuler, Gregory; Gapontsev, Valentin

    2018-02-01

    Three lasers were directly compared, including the Ho:YAG laser (λ = 2100 nm), Tm fiber laser (λ = 1940 nm) operating in 3 different modes (CW, regular pulse, and super pulse), and blue diode laser (λ = 442 nm) for vaporization and coagulation efficiency for treating blood-rich soft tissues, ex vivo, in a porcine kidney model at quasi-contact cutting in water. In addition, experimental results were compared with published data on performance of KTP laser (λ = 532 nm) at similar experimental settings (Power = 60 W and cutting speed = 2 mm/s). Tm fiber laser in pulsed mode and blue laser produced highest vaporization rates of 3.7 and 3.4 mm3/s, respectively. Tm fiber laser (in both CW and pulsed modes) also produced the largest coagulation zone among the laser sources tested. A carbonization zone was observed for Tm fiber laser in CW and pulsed modes, as well as for the blue diode laser. Tm fiber laser in super-pulse mode and Ho:YAG laser both resulted in irregular coagulation zones without carbonization. Comparison with known data for KTP laser revealed that tissue effects of the blue laser are similar to that of the KTP laser. These results suggest that the combination of the two lasers (Tm fiber and blue diode) in one system may achieve high cutting efficiency and optimal coagulation for hemostasis during surgical treatment. Ex vivo testing of the combined system revealed feasibility of this approach. The combination of the CW Tm fiber laser (120W) and the blue diode laser (60W) emitting through a combination tip were compared with CW 120 W Tm fiber laser alone and 120 W Ho:YAG laser. Vaporization rates measured 34, 28, and 6 mm3/s, and coagulation zones measured 0.6, 1.3, and 1.7 mm, respectively. A carbonization zone was only observed with CW Tm fiber laser. The vaporization rate of combined CW Tm fiber laser / blue diode laser was comparable to published data for KTP laser for equivalent total power. Thus, high-power blue diode laser, Tm fiber laser, and their combination may provide an alternative to conventional Ho:YAG and KTP lasers for applications in urology and other surgical fields.

  13. Design and test of SX-FEL cavity BPM

    NASA Astrophysics Data System (ADS)

    Yuan, Ren-Xian; Zhou, Wei-Min; Chen, Zhi-Chu; Yu, Lu-Yang; Wang, Bao-Pen; Leng, Yong-Bin

    2013-11-01

    This paper reports the design and cold test of the cavity beam position monitor (CBPM) for SX-FEL to fulfill the requirement of beam position measurement resolution of less than 1 μm, even 0.1 μm. The CBPM was optimized by using a coupling slot to damp the TM010 mode in the output signal. The isolation of TM010 mode is about 117 dB, and the shunt impedance is about 200 Ω@4.65 GHz with the quality factor 80 from MAFIA simulation and test result. A special antenna was designed to load power for reducing excitation of other modes in the cavity. The resulting output power of TM110 mode was about 90 mV/mm when the source was 6 dBm, and the accomplishable minimum voltage was about 200 μV. The resolution of the CBPM was about 0.1 μm from the linear fitting result based on the cold test.

  14. Ab Initio structure prediction for Escherichia coli: towards genome-wide protein structure modeling and fold assignment

    PubMed Central

    Xu, Dong; Zhang, Yang

    2013-01-01

    Genome-wide protein structure prediction and structure-based function annotation have been a long-term goal in molecular biology but not yet become possible due to difficulties in modeling distant-homology targets. We developed a hybrid pipeline combining ab initio folding and template-based modeling for genome-wide structure prediction applied to the Escherichia coli genome. The pipeline was tested on 43 known sequences, where QUARK-based ab initio folding simulation generated models with TM-score 17% higher than that by traditional comparative modeling methods. For 495 unknown hard sequences, 72 are predicted to have a correct fold (TM-score > 0.5) and 321 have a substantial portion of structure correctly modeled (TM-score > 0.35). 317 sequences can be reliably assigned to a SCOP fold family based on structural analogy to existing proteins in PDB. The presented results, as a case study of E. coli, represent promising progress towards genome-wide structure modeling and fold family assignment using state-of-the-art ab initio folding algorithms. PMID:23719418

  15. a Probability-Based Statistical Method to Extract Water Body of TM Images with Missing Information

    NASA Astrophysics Data System (ADS)

    Lian, Shizhong; Chen, Jiangping; Luo, Minghai

    2016-06-01

    Water information cannot be accurately extracted using TM images because true information is lost in some images because of blocking clouds and missing data stripes, thereby water information cannot be accurately extracted. Water is continuously distributed in natural conditions; thus, this paper proposed a new method of water body extraction based on probability statistics to improve the accuracy of water information extraction of TM images with missing information. Different disturbing information of clouds and missing data stripes are simulated. Water information is extracted using global histogram matching, local histogram matching, and the probability-based statistical method in the simulated images. Experiments show that smaller Areal Error and higher Boundary Recall can be obtained using this method compared with the conventional methods.

  16. Herman Method[TM]. What Works Clearinghouse Intervention Report

    ERIC Educational Resources Information Center

    What Works Clearinghouse, 2010

    2010-01-01

    The "Herman Method"[TM] teaches reading in small groups of up to three students. The curriculum provides instruction in phonemic awareness, phonics, fluency, vocabulary, and reading comprehension, while also teaching spelling and writing. It contains 20 modules of instruction through a fifth grade level. Each module includes a reading,…

  17. Energy transfer and 2.0 μm emission in Tm{sup 3+}/Ho{sup 3+} co-doped α-NaYF{sub 4} single crystals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Feng, Zhigang; Yang, Shuo; Xia, Haiping, E-mail: hpxcm@nbu.edu.cn

    2016-04-15

    Highlights: • Cubic NaYF{sub 4} single crystals co-doped with ∼1.90 mol% Tm{sup 3+} and various Ho{sup 3+} concentrations were grown by Bridgman method. • The maximum fluorescence lifetime was 23.23 ms for Tm{sup 3+} (1.90 mol%)/Ho{sup 3+} (3.89 mol%) co-doped α-NaYF{sub 4}. • The obtained energy transfer rate (W{sub ET}) and energy transfer efficiency (η) of Tm{sup 3+}:{sup 3}F{sub 4} are 1077 s{sup −1} and 95.0%, respectively. • The maximum emission cross section reached 1.06 × 10{sup −20} cm{sup 2}. - Abstract: Cubic NaYF{sub 4} single crystals co-doped with ∼1.90 mol% Tm{sup 3+} and various Ho{sup 3+} concentrations were grownmore » by Bridgman method. The energy transfer from Tm{sup 3+} to Ho{sup 3+} and the optimum fluorescence emission around 2.04 μm of Ho{sup 3+} ion were investigated based on the measured absorption spectra, emission spectra, emission cross section and decay curves under excitation of 800 nm LD. The emission intensity at 2.04 μm increased with the increase of Ho{sup 3+} concentration from 0.96 mol% to 3.89 mol% when the concentration of Tm{sup 3+} was held constantly at ∼1.90 mol%. Moreover, the maximum emission cross section reached 1.06 × 10{sup −20} cm{sup 2} and the maximum fluorescence lifetime was 23.23 ms for Tm{sup 3+}(1.90 mol%)/Ho{sup 3+}(3.89 mol%) co-doped one. According to the measured lifetime of Tm{sup 3+} single-doped and Tm{sup 3+}/Ho{sup 3+} co-doped samples, the maximum energy transfer efficiency of Tm{sup 3+}:{sup 3}F{sub 4} level was 95.0%. Analysis on the fluorescence dynamics indicated that electric dipole–dipole is dominant for the energy transfer from Tm{sup 3+} to Ho{sup 3+}.« less

  18. Magnetic properties of carbon-coated, ferromagnetic nanoparticles produced by a carbon-arc method

    NASA Astrophysics Data System (ADS)

    Brunsman, E. M.; Sutton, R.; Bortz, E.; Kirkpatrick, S.; Midelfort, K.; Williams, J.; Smith, P.; McHenry, M. E.; Majetich, S. A.; Artman, J. O.; De Graef, M.; Staley, S. W.

    1994-05-01

    The Krätschmer-Huffman carbon-arc method of preparing fullerenes has been used to generate carbon-coated transition metal (TM) and TM-carbide nanocrystallites. The magnetic nanocrystallites were extracted from the soot with a magnetic gradient field technique. For TM=Co the majority of nanocrystals exist as nominally spherical particles, 0.5-5 nm in radius. Hysteretic and temperature-dependent magnetic response, in randomly and magnetically aligned powder samples frozen in epoxy, correspond to fine particle magnetism associated with monodomain TM particles. The magnetization exhibits a unique functional dependence on H/T, and hysteresis below a blocking temperature TB. Below TB, the temperature dependence of the coercivity can be expressed as Hc=Hc0[1-(T/TB)1/2], where Hc0 is the 0 K coercivity.

  19. Improved wetland remote sensing in Yellowstone National Park using classification trees to combine TM imagery and ancillary environmental data

    USGS Publications Warehouse

    Wright, C.; Gallant, Alisa L.

    2007-01-01

    The U.S. Fish and Wildlife Service uses the term palustrine wetland to describe vegetated wetlands traditionally identified as marsh, bog, fen, swamp, or wet meadow. Landsat TM imagery was combined with image texture and ancillary environmental data to model probabilities of palustrine wetland occurrence in Yellowstone National Park using classification trees. Model training and test locations were identified from National Wetlands Inventory maps, and classification trees were built for seven years spanning a range of annual precipitation. At a coarse level, palustrine wetland was separated from upland. At a finer level, five palustrine wetland types were discriminated: aquatic bed (PAB), emergent (PEM), forested (PFO), scrub–shrub (PSS), and unconsolidated shore (PUS). TM-derived variables alone were relatively accurate at separating wetland from upland, but model error rates dropped incrementally as image texture, DEM-derived terrain variables, and other ancillary GIS layers were added. For classification trees making use of all available predictors, average overall test error rates were 7.8% for palustrine wetland/upland models and 17.0% for palustrine wetland type models, with consistent accuracies across years. However, models were prone to wetland over-prediction. While the predominant PEM class was classified with omission and commission error rates less than 14%, we had difficulty identifying the PAB and PSS classes. Ancillary vegetation information greatly improved PSS classification and moderately improved PFO discrimination. Association with geothermal areas distinguished PUS wetlands. Wetland over-prediction was exacerbated by class imbalance in likely combination with spatial and spectral limitations of the TM sensor. Wetland probability surfaces may be more informative than hard classification, and appear to respond to climate-driven wetland variability. The developed method is portable, relatively easy to implement, and should be applicable in other settings and over larger extents.

  20. Comparison of rectal, tympanic membrane and axillary temperature measurement methods in dogs.

    PubMed

    Lamb, V; McBrearty, A R

    2013-11-30

    The aim of this study was to compare axillary and tympanic membrane (TM) temperature measurements to rectal temperature in a large group of clinical canine patients. We also sought to ascertain whether certain factors affected the differences between the measurements and to compare the ease of measurement. Axillary temperatures were easy to obtain but tended to be lower than rectal readings (median difference 0.6°C). In 54.7 per cent of dogs there was a difference of >0.5°C between the two readings. Weight, coat length, body condition score and breed size were significantly associated with the difference between the rectal and axillary temperature. TM temperatures were more similar to rectal temperatures (median difference 0°C) but in 25 per cent of dogs, there was a difference of >0.5°C between rectal and TM readings. TM measurements were less well tolerated than axillary measurements. None of the factors assessed were associated with the difference between the rectal and TM temperature. As a difference of >0.5°C has previously been described as unacceptable for different methods of temperature measurement, neither axillary nor TM temperatures are interchangeable with rectal temperatures for the measurement of body temperature.

  1. A Randomized Trial of Extended Telephone-Based Continuing Care for Alcohol Dependence: Within-Treatment Substance Use Outcomes

    ERIC Educational Resources Information Center

    McKay, James R.; Van Horn, Deborah H. A.; Oslin, David W.; Lynch, Kevin G.; Ivey, Megan; Ward, Kathleen; Drapkin, Michelle L.; Becher, Julie R.; Coviello, Donna M.

    2010-01-01

    Objective: The study tested whether adding up to 18 months of telephone continuing care, either as monitoring and feedback (TM) or longer contacts that included counseling (TMC), to intensive outpatient programs (IOPs) improved outcomes for alcohol-dependent patients. Method: Participants (N = 252) who completed 3 weeks of IOP were randomized to…

  2. Cysteine Substitution of Transmembrane Domain Amino Acids Alters the Ethanol Inhibition of GluN1/GluN2A N-Methyl-d-Aspartate Receptors

    PubMed Central

    Xu, Minfu; Smothers, C. Thetford

    2015-01-01

    N-Methyl-d-aspartate receptors (NMDARs) are inhibited by behaviorally relevant concentrations of ethanol, and residues within transmembrane (TM) domains of NMDARs, including TM3 GluN1 phenylalanine 639 (F639), regulate this sensitivity. In the present study, we used cysteine (C) mutagenesis to determine whether there are additional residues within nearby TM domains that regulate ethanol inhibition on NMDARs. GluN1(F639C)/GluN2A receptors were less inhibited by ethanol than wild-type receptors, and inhibition was restored to wild-type levels following treatment with ethanol-like methanethiosulfonate reagents. Molecular modeling identified six residues in the GluN1 TM1 domain (valine V566; serine S569) and the GluN2A TM4 domain (methionine, M817; V820, F821, and leucine, L824) that were in close vicinity to the TM3 F639 residue, and these were individually mutated to cysteine and tested for ethanol inhibition and receptor function. The F639C-induced decrease in ethanol inhibition was blunted by coexpression of GluN1 TM1 mutants V566C and S569C, and statistically significant interactions were observed for ethanol inhibition among V566C, F639C, and GluN2A TM4 mutants V820C and F821C and S569C, F639C, and GluN2A TM4 mutants F821C and L824C. Ethanol inhibition was also reduced when either GluN1 TM1 mutant V566C or S569C was combined with GluN2A V820C, suggesting a novel TM1:TM4 intrasubunit site of action for ethanol. Cysteines substituted at TM3 and TM4 sites previously suggested to interact with ethanol had less dramatic effects on ethanol inhibition. Overall, the results from these studies suggest that interactions among TM1, TM3, and TM4 amino acids in NMDARs are important determinants of ethanol action at these receptors. PMID:25635140

  3. Modernization of Defense Logistics Standard Systems. Establishing the Functional Baseline. Volume 2. Appendix H

    DTIC Science & Technology

    1991-09-01

    and "DD" is the numeric value of the day (01-31). [61 Time ( TM ). The time type is symbolized by the representation " TM ." Format for this type is...VERSION ID M DT 06/06 M TM 04/04 M ID 01/01 M ID 05/05 ISA13 112 ISA14 113 ISA15 114 ISA16 115INTERCHANGE *ACKNOWLEDG. * S1TEST 14 * SUBELEMENT N CTRL...Max - 6 Date of the interchange. DLMS Usage: As above. 109 Interchange Time Type - TM Min - 4 Max - 4 Time of the interchange. DLMS Usage: As above

  4. High Mobility Group N Proteins Modulate the Fidelity of the Cellular Transcriptional Profile in a Tissue- and Variant-specific Manner*

    PubMed Central

    Kugler, Jamie E.; Horsch, Marion; Huang, Di; Furusawa, Takashi; Rochman, Mark; Garrett, Lillian; Becker, Lore; Bohla, Alexander; Hölter, Sabine M.; Prehn, Cornelia; Rathkolb, Birgit; Racz, Ildikó; Aguilar-Pimentel, Juan Antonio; Adler, Thure; Adamski, Jerzy; Beckers, Johannes; Busch, Dirk H.; Eickelberg, Oliver; Klopstock, Thomas; Ollert, Markus; Stöger, Tobias; Wolf, Eckhard; Wurst, Wolfgang; Yildirim, Ali Önder; Zimmer, Andreas; Gailus-Durner, Valérie; Fuchs, Helmut; Hrabě de Angelis, Martin; Garfinkel, Benny; Orly, Joseph; Ovcharenko, Ivan; Bustin, Michael

    2013-01-01

    The nuclei of most vertebrate cells contain members of the high mobility group N (HMGN) protein family, which bind specifically to nucleosome core particles and affect chromatin structure and function, including transcription. Here, we study the biological role of this protein family by systematic analysis of phenotypes and tissue transcription profiles in mice lacking functional HMGN variants. Phenotypic analysis of Hmgn1tm1/tm1, Hmgn3tm1/tm1, and Hmgn5tm1/tm1 mice and their wild type littermates with a battery of standardized tests uncovered variant-specific abnormalities. Gene expression analysis of four different tissues in each of the Hmgntm1/tm1 lines reveals very little overlap between genes affected by specific variants in different tissues. Pathway analysis reveals that loss of an HMGN variant subtly affects expression of numerous genes in specific biological processes. We conclude that within the biological framework of an entire organism, HMGNs modulate the fidelity of the cellular transcriptional profile in a tissue- and HMGN variant-specific manner. PMID:23620591

  5. An Analysis of Coupling between the x1 and x12 Interferometers for LISA Pathfinder

    NASA Astrophysics Data System (ADS)

    Howard, Brittany

    2017-01-01

    Due to tolerances in the manufacturing process, noise from the jittering of the spacecraft housing LISA Pathfinder (LPF) is appearing in the differential measurement between its two test masses (TM's). This phenomenon manifests as a small but measurable coupling between the readouts of LPF's two heterodyne interferometers, x1 and x12. In this study, two LISA Pathfinder experiments are analyzed using three methods in an effort to characterize and quantify the coupling as well as to potentially identify its source. The main question considered is this: does the coupling change with the absolute displacement between the TM's? As a result of this work, reliable values for coupling between LPF's x1 and x12 interferometers are found, and they are seen to depend on the absolute displacement between the test masses to some degree. Completed at the Albert Einstein Institute for Gravitational Physics under the International REU program from the University of Florida.

  6. Differential Diagnosis in Idiopathic Granulomatous Mastitis and Tuberculous Mastitis

    PubMed Central

    Seo, Hee Ri Na; Na, Kuk Young; Yim, Hyun Ee; Kim, Tae Hee; Kang, Doo Kyoung; Oh, Ki Keun; Kang, Seok Yun; An, Young-Sil; Chun, Mison; Kim, Woojae; Park, Rae Woong; Jung, Yong Sik

    2012-01-01

    Purpose Idiopathic granulomatous mastitis (IGM) is a rare chronic inflammatory disease of unknown etiology. The diagnosis of IGM requires that other granulomatous lesions in the breast be excluded. Tuberculous mastitis (TM) is also an uncommon disease that is often difficult to differentiate from IGM. The purpose of this study is to develop a new algorithm for the differential diagnosis and treatment of IGM and TM. Methods Medical records of 68 patients (58 with IGM and 10 with TM) between July 1999 and February 2009 were retrospectively reviewed. Results The mean age of the patients was 33.5 (IGM) and 40 (TM) years (p=0.018). The median follow-up was 84 months. Of the total 10 patients with TM, 5 patients had a history of pulmonary tuberculosis. The most common symptoms of the diseases were breast lump and pain. However, axillary lymphadenopathy was more seen in TM (50%) compared to IGM (20.6%) (p=0.048). TM showed more cancer-mimicking findings on radiologic study (p=0.028). In IGM, 48 patients (82.7%) underwent surgical wide excision and 21 patients (36.2%) were managed with corticosteroid therapy and antibiotics. All of the TM patients received anti-tuberculosis medications and 9 patients (90%) underwent wide excision. The mean treatment duration was 2.8 months in IGM and 8.4 months in TM. Recurrence developed in 5 patients (8.6%) in IGM and 1 patient (10%) in TM. Conclusion This study shows different characteristics between IGM and TM. The IGM patients were younger and had more mastalgia symptoms than the TM patients. Axillary lymphadenopathy was seen more often in TM patients. Half of the TM patients had pulmonary tuberculosis or tuberculosis lymphadenitis. Surgical wide excision might be both therapeutic and useful for providing an exact diagnosis. PMID:22493637

  7. Specification for wide channel bandwidth one-inch video tape

    NASA Technical Reports Server (NTRS)

    Perry, Jimmy L.

    1988-01-01

    Standards and controls are established for the procurement of wide channel bandwidth one inch video magnetic recording tapes for Very Long Base Interferometer (VLBI) system applications. The Magnetic Tape Certification Facility (MTCF) currently maintains three specifications for the Quality Products List (QPL) and acceptance testing of magnetic tapes. NASA-TM-79724 is used for the QPL and acceptance testing of new analog tapes; NASA-TM-80599 is used for QPL and acceptance testing of new digital tapes; and NASA-TM-100702 is used for the QPL and acceptance testing of new IBM/IBM compatible 3480 magnetic tape cartridges. This specification will be used for the QPL and acceptance testing of new wide channel bandwidth one inch video magnetic recording tapes. The one inch video tapes used by the Jet Propulsion Lab., the Deep Space Network and the Haystack Observatory will be covered by this specification. These NASA stations will use the video tapes for their VLBI system applications. The VLBI system is used for the tracking of quasars and the support of interplanetary exploration.

  8. Validation of the firefighter WFI treadmill protocol for predicting VO2 max.

    PubMed

    Dolezal, B A; Barr, D; Boland, D M; Smith, D L; Cooper, C B

    2015-03-01

    The Wellness-Fitness Initiative submaximal treadmill exercise test (WFI-TM) is recommended by the US National Fire Protection Agency to assess aerobic capacity (VO2 max) in firefighters. However, predicting VO2 max from submaximal tests can result in errors leading to erroneous conclusions about fitness. To investigate the level of agreement between VO2 max predicted from the WFI-TM against its direct measurement using exhaled gas analysis. The WFI-TM was performed to volitional fatigue. Differences between estimated VO2 max (derived from the WFI-TM equation) and direct measurement (exhaled gas analysis) were compared by paired t-test and agreement was determined using Pearson Product-Moment correlation and Bland-Altman analysis. Statistical significance was set at P < 0.05. Fifty-nine men performed the WFI-TM. Mean (standard deviation) values for estimated and measured VO2 max were 44.6 (3.4) and 43.6 (7.9) ml/kg/min, respectively (P < 0.01). The mean bias by which WFI-TM overestimated VO2 max was 0.9ml/kg/min with a 95% prediction interval of ±13.1. Prediction errors for 22% of subjects were within ±5%; 36% had errors greater than or equal to ±15% and 7% had greater than ±30% errors. The correlation between predicted and measured VO2 max was r = 0.55 (standard error of the estimate = 2.8ml/kg/min). WFI-TM predicts VO2 max with 11% error. There is a tendency to overestimate aerobic capacity in less fit individuals and to underestimate it in more fit individuals leading to a clustering of values around 42ml/kg/min, a criterion used by some fire departments to assess fitness for duty. © The Author 2015. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  9. Neurocognitive dysfunction in children with β thalassemia major: psychometric, neurophysiologic and radiologic evaluation.

    PubMed

    Elalfy, M S; Aly, R H; Azzam, H; Aboelftouh, K; Shatla, R H; Tarif, M; Abdatty, M; Elsayed, R M

    2017-12-01

    To evaluate the impact of iron chelating drugs and serum ferritin on the neurocognitive functions of patients with β thalassemia major (β-TM), using psychometric, neurophysiologic and radiologic tests. Eighty children with β-TM were enrolled into the study and were compared to 40 healthy controls. All participants were evaluated by measuring serum ferritin, neurocognitive assessment by Benton Visual Retention Test, Wechsler Intelligence Scale for Children, Wisconsin Card Sort Test, P300 and magnetic resonance spectroscopy (MRS). WISC in our study showed that 40% of cases were borderline mental function as regards total IQ. Neurophysiologic tests were significantly impaired in patients compared to control group, with significant impairment in those receiving desferrioxamine (DFO). P300 amplitude was significantly lower in cases compared to controls (2.24 and 4.66 uv, respectively), recording the shortest amplitude in patients receiving DFO. Altered metabolic markers in the brain were detected by MRS in the form of reduced N-acetylaspartate to creatine ratio in 78.3% of our cases. There were significant correlations between psychometric tests and both neurophysiologic (P300) and radiologic (MRS) tests. β-TM is associated with neurocognitive impairment that can be assessed by psychometric, neurophysiologic and radiologic tests. The role of hemosiderosis and iron chelation therapy on cognitive functioning still need more research. β-TM: beta thalassemia major; DFO: Dysferal; DFP: Deferiprone; DFX: Deferasirox; WISC: Wechsler Intelligence Scale for Children; VIQ: verbal IQ; PIQ: performance IQ; TIQ: total IQ; BVRT: Benton Visual Retention Test; WCST: Wisconsin Card Sort Test; MRS: Magnetic resonant spectroscopy; NAA/Cr ratio: N-acetylaspartate to creatine ratio.

  10. Evidence-based guideline: clinical evaluation and treatment of transverse myelitis: report of the Therapeutics and Technology Assessment Subcommittee of the American Academy of Neurology.

    PubMed

    Scott, T F; Frohman, E M; De Seze, J; Gronseth, G S; Weinshenker, B G

    2011-12-13

    To assess the evidence for diagnostic tests and therapies for transverse myelitis (TM) and make evidence-based recommendations. A review of the published literature from 1966 to March 2009 was performed, with evidence-based classification of relevant articles. Level B recommendations: neuromyelitis optica (NMO)-immunoglobulin G (IgG) antibodies should be considered useful to determine TM cause in patients presenting with clinical acute complete transverse myelitis (ACTM) features. The presence of NMO-IgG antibodies (aquaporin-4-specific antibodies) should be considered useful in determining increased TM recurrence risk. Level C recommendations: in suspected TM, distinction between ACTM or acute partial transverse myelitis may be considered useful to determine TM etiology and risk for relapse (more common with APTM). Age and gender may be considered useful to determine etiology in patients presenting with TM syndrome, with spinal infarcts seen more often in older patients and more female than male patients having TM due to multiple sclerosis (MS). Brain MRI characteristics consistent with those of MS may be considered useful to predict conversion to MS after a first partial TM episode. Longer spinal lesions extending over >3 vertebral segments may be considered useful in determining NMO vs MS. CSF examination for cells and oligoclonal bands may be considered useful to determine the cause of the TM syndrome. Plasma exchange may be considered in patients with TM who fail to improve after corticosteroid treatment. Rituximab may be considered in patients with TM due to NMO to decrease the number of relapses. Level U recommendations: there is insufficient evidence to support or refute the efficacy of other TM therapies or the usefulness of ethnicity to determine the cause of a subacute myelopathy.

  11. The 2 Degrees of Freedom facility in Firenze for the study of weak forces

    NASA Astrophysics Data System (ADS)

    Marconi, L.; Stanga, R.; Lorenzini, M.; Grimani, C.; Bassan, M.; Pucacco, G.; Di Fiore, L.; De Rosa, R.; Garufi, F.; Milano, L.

    2010-05-01

    The LISA test-mass (TM) is sensitive to weak forces along all 6 Degrees of Freedom (DoFs). Extensi ve ground test ing is required in order to evaluate the influence of cross-talks of read-outs and actuators operating on different DoFs. To best represent the flight conditions, we developed in Firenze a facility with 2 soft DoFs. Using this facility we measure the forces and stiffnesses acting simultaneously along the 2 soft DoFs, and, more specifically, we will be able to de b ug residual couplings between the TM and the capacitive position sensor that reads the TM position, and to measure actuation cross talks with closed feedback loop. The facility is now ready, and here we report on the co mmi ssioning test s, and on the first measurements.

  12. Interleukin 10 knockout frail mice develop cardiac and vascular dysfunction with increased age☆

    PubMed Central

    Sikka, Gautam; Miller, Karen L.; Steppan, Jochen; Pandey, Deepesh; Jung, Sung M.; Fraser, Charles D.; Ellis, Carla; Ross, Daniel; Vandegaer, Koenraad; Bedja, Djahida; Gabrielson, Kathleen; Walston, Jeremy D.; Berkowitz, Dan E.; Barouch, Lili A.

    2013-01-01

    Cardiovascular dysfunction is a primary independent predictor of age-related morbidity and mortality. Frailty is associated with activation of inflammatory pathways and fatigue that commonly presents and progresses with age. Interleukin 10 (IL-10), the cytokine synthesis inhibitory factor, is an anti-inflammatory cytokine produced by immune and non-immune cells. Homozygous deletion of IL-10 in mice yields a phenotype that is consistent with human frailty, including age-related increases in serum inflammatory mediators, muscular weakness, higher levels of IGF-1 at midlife, and early mortality. While emerging evidence suggests a role for IL-10 in vascular protection, a clear mechanism has not yet been elucidated. Methods In order to evaluate the role of IL-10 in maintenance of vascular function, force tension myography was utilized to access ex-vivo endothelium dependent vasorelaxation in vessels isolated from IL-10 knockout IL-10(tm/tm) and control mice. Pulse wave velocity ((PWV), index of stiffness) of vasculature was measured using ultrasound and blood pressure was measured using the tail cuff method. Echocardiography was used to elucidated structure and functional changes in the heart. Results Mean arterial pressures were significantly higher in IL-10(tm/tm) mice as compared to C57BL6/wild type (WT) controls. PWV was increased in IL-10(tm/tm) indicating stiffer vasculature. Endothelial intact aortic rings isolated from IL-10(tm/tm) mice demonstrated impaired vasodilation at low acetylcholine doses and vasoconstriction at higher doses whereas vasorelaxation responses were preserved in rings from WT mice. Cyclo-oxygenase (COX-2)/thromboxane A2 inhibitors improved endothelial dependent vasorelaxation and reversed vasoconstriction. Left ventricular end systolic diameter, left ventricular mass, isovolumic relaxation time, fractional shortening and ejection fraction were all significantly different in the aged IL-10(tm/tm) mice compared to WT mice. Conclusion Aged IL-10(tm/tm) mice have stiffer vessels and decreased vascular relaxation due to an increase in eicosanoids, specifically COX-2 activity and resultant thromboxane A2 receptor activation. Our results also suggest that aging IL-10(tm/tm) mice have an increased heart size and impaired cardiac function compared to age-matched WT mice. While further studies will be necessary to determine if this age-related phenotype develops as a result of inflammatory pathway activation or lack of IL-10, it is essential for maintaining the vascular compliance and endothelial function during the aging process. Given that a similar cardiovascular phenotype is present in frail, older adults, these findings further support the utility of the IL-10(tm/tm) mouse as a model of frailty. PMID:23159957

  13. Using Interdisciplinary Research Methods to Revise and Strengthen the NWS TsunamiReadyTM Community Recognition Program

    NASA Astrophysics Data System (ADS)

    Scott, C.; Gregg, C. E.; Ritchie, L.; Stephen, M.; Farnham, C.; Fraser, S. A.; Gill, D.; Horan, J.; Houghton, B. F.; Johnson, V.; Johnston, D.

    2013-12-01

    The National Tsunami Hazard Mitigation Program (NTHMP) partnered with the National Weather Service (NWS) in early 2000 to create the TsunamiReadyTM Community Recognition program. TsunamiReadyTM, modeled after the older NWS StormReadyTM program, is designed to help cities, towns, counties, universities and other large sites in coastal areas reduce the potential for disastrous tsunami-related consequences. To achieve TsunamiReadyTM recognition, communities must meet certain criteria aimed at better preparing a community for tsunami, including specific actions within the following categories: communications and coordination, tsunami warning reception, local warning dissemination, community preparedness, and administration. Using multidisciplinary research methods and strategies from Public Health; Psychology; Political, Social and Physical Sciences and Evaluation, our research team is working directly with a purposive sample of community stakeholders in collaboration and feedback focus group sessions. Invitation to participate is based on a variety of factors including but not limited to an individual's role as a formal or informal community leader (e.g., in business, government, civic organizations), or their organization or agency affiliation to emergency management and response. Community organizing and qualitative research methods are being used to elicit discussion regarding TsunamiReadyTM requirements and the division of requirements based on some aspect of tsunami hazard, vulnerability and risk, such as proximity to active or passive plate margins or subduction zone generated tsunamis versus earthquake-landslide generated tsunamis . The primary aim of this research is to use social science to revise and refine the NWS TsunamiReadyTM Guidelines in an effort to better prepare communities to reduce risk to tsunamis.

  14. Towards Longitudinal Mapping of Extracellular pH in Gliomas

    PubMed Central

    Huang, Yuegao; Coman, Daniel; Herman, Peter; Rao, Jyotsna U.; Maritim, Samuel; Hyder, Fahmeed

    2016-01-01

    Biosensor Imaging of Redundant Deviation in Shifts (BIRDS), an ultrafast chemical shift imaging technique, requires infusion of paramagnetic probes like 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetrakis(methylene phosphonate (DOTP8−) complexed with thulium (Tm3+) ion (i.e., TmDOTP5−), where the pH-sensitive resonances of hyperfine-shifted nonexchangeable protons contained within the paramagnetic magnetic resonance probe are detected. While imaging extracellular pH (pHe) with BIRDS meets an important cancer research need by mapping the intratumoral-peritumoral pHe gradient, the surgical intervention used to raise the probe’s plasma concentration limits longitudinal scans on the same subject. Here we describe using probenecid (i.e., an organic anion transporter inhibitor) to temporarily restrict renal clearance of TmDOTP5−, thereby facilitating molecular imaging by BIRDS without surgical intervention. Co-infusion of probenecid with TmDOTP5− increased the probe’s distribution into various organs, including the brain, compared with when infusing TmDOTP5− alone. In vivo BIRDS data using probenecid/TmDOTP5− co-infusion method in rats bearing RG2, 9L, and U87 brain tumors showed intratumoral-peritumoral pHe gradients that were unaffected by the probe dose. This co-infusion method can be used for pHe mapping with BIRDS in preclinical models for tumor characterization and therapeutic monitoring given the possibility of repeated scans with BIRDS (e.g., over days and even weeks) in the same subject. The longitudinal pHe readout by probenecid/TmDOTP5− co-infusion method for BIRDS adds translational value in tumor assessment and treatment. PMID:27472471

  15. [Evaluation of mechanical properties of four kinds of composite resins for inlay].

    PubMed

    Jiang, Ling-ling; Liu, Hong; Wang, Jin-rui

    2011-04-01

    To evaluate the compressive strength, wear resistance, hardness, and soaking fatigue of four composite resins for inlay, which were Ceramage, Surefil, Solitaire 2, and Filtek(TM) Z350. Scanning electron microscope (SEM) was used to analyze the microstructures of the wear surface of the samples. The samples for the compression test, hardness test and wear were prepared. The samples were respectively immersed in the artificial saliva for 2 months for immersed test. The electronic universal testing machine was used to test the compression strength. Hardness was quantified by micro-Vickers hardness test. The wear tester was used for the wear test. SEM was used to analyze the microstructures of the wear surface of samples. All the data was analyzed by using SPSS17.0 software package. The compressive strength of Surefil was the biggest which was significantly higher than the other three resins before soaking (P<0.05). After soaking, there was no significant difference between the composite resins (P>0.05). The hardness of Surefil was the best, and significant difference was found between the hardness of the materials before soaking (P<0.05). After soaking, no significant difference was obtained between the hardness of Surefil and Filtek(TM) Z350 (P>0.05).The compressive strength and hardness of 4 materials decreased after soaking in artificial saliva. But only the compressive strength of Filtek(TM) Z350 had no significant change after immersion (P>0.05). Except Filtek(TM) Z350, there was significant difference between the other three materials (P<0.05). Significant relationship was observed between wear and hardness of three materials (P<0.05). According to SEM observation, abrasive wear occurred in four materials. In addition to Ceramage, other composite resins had adhesive wear. The mechanical property of Surefil is the best, and it is suitable for fabrication of posterior inlay. Filtek(TM) Z350's ability to resist fatigue is the best.

  16. Organic fuel cell methods and apparatus

    NASA Technical Reports Server (NTRS)

    Narayanan, Sekharipuram R. (Inventor); Frank, Harvey A. (Inventor); Halpert, Gerald (Inventor); Surampudi, Subbarao (Inventor); Prakash, G. K. Surya (Inventor); Vamos, Eugene (Inventor); Olah, George A. (Inventor)

    2001-01-01

    A liquid organic fuel cell is provided which employs a solid electrolyte membrane. An organic fuel, such as a methanol/water mixture, is circulated past an anode of a cell while oxygen or air is circulated past a cathode of the cell. The cell solid electrolyte membrane is preferably fabricated from Nafion.TM.. Additionally, a method for improving the performance of carbon electrode structures for use in organic fuel cells is provided wherein a high surface-area carbon particle/Teflon.TM.-binder structure is immersed within a Nafion.TM./methanol bath to impregnate the electrode with Nafion.TM.. A method for fabricating an anode for use in a organic fuel cell is described wherein metal alloys are deposited onto the electrode in an electro-deposition solution containing perfluorooctanesulfonic acid. A fuel additive containing perfluorooctanesulfonic acid for use with fuel cells employing a sulfuric acid electrolyte is also disclosed. New organic fuels, namely, trimethoxymethane, dimethoxymethane, and trioxane are also described for use with either conventional or improved fuel cells.

  17. Organic fuel cell methods and apparatus

    NASA Technical Reports Server (NTRS)

    Surampudi, Subbarao (Inventor); Narayanan, Sekharipuram R. (Inventor); Vamos, Eugene (Inventor); Halpert, Gerald (Inventor); Olah, George A. (Inventor); Frank, Harvey A. (Inventor); Prakash, G. K. Surya (Inventor)

    2004-01-01

    A liquid organic, fuel cell is provided which employs a solid electrolyte membrane. An organic fuel, such as a methanol/water mixture, is circulated past an anode of a cell while oxygen or air is circulated past a cathode of the cell. The cell solid electrolyte membrane is preferably fabricated from Nafion.TM.. Additionally, a method for improving the performance of carbon electrode structures for use in organic fuel cells is provided wherein a high surface-area carbon particle/Teflon.TM.-binder structure is immersed within a Nafion.TM./methanol bath to impregnate the electrode with Nafion.TM.. A method for fabricating an anode for use in a organic fuel cell is described wherein metal alloys are deposited onto the electrode in an electro-deposition solution containing perfluorooctanesulfonic acid. A fuel additive containing perfluorooctanesulfonic acid for use with fuel cells employing a sulfuric acid electrolyte is also disclosed. New organic fuels, namely, trimethoxymethane, dimethoxymethane, and trioxane are also described for use with either conventional or improved fuel cells.

  18. Organic fuel cell methods and apparatus

    NASA Technical Reports Server (NTRS)

    Frank, Harvey A. (Inventor); Halpert, Gerald (Inventor); Surampudi, Subbarao (Inventor); Olah, George A. (Inventor); Vamos, Eugene (Inventor); Narayanan, Sekharipuram R. (Inventor); Prakash, G. K. Surya (Inventor)

    2008-01-01

    A liquid organic, fuel cell is provided which employs a solid electrolyte membrane. An organic fuel, such as a methanol/water mixture, is circulated past an anode of a cell while oxygen or air is circulated past a cathode of the cell. The cell solid electrolyte membrane is preferably fabricated from Nafion.TM.. Additionally, a method for improving the performance of carbon electrode structures for use in organic fuel cells is provided wherein a high surface-area carbon particle/Teflon.TM.-binder structure is immersed within a Nafion.TM./methanol bath to impregnate the electrode with Nafion.TM.. A method for fabricating an anode for use in a organic fuel cell is described wherein metal alloys are deposited onto the electrode in an electro-deposition solution containing perfluorooctanesulfonic acid. A fuel additive containing perfluorooctanesulfonic acid for use with fuel cells employing a sulfuric acid electrolyte is also disclosed. New organic fuels, namely, trimethoxymethane, dimethoxymethane, and trioxane are also described for use with either conventional or improved fuel cells.

  19. Study on biofilm-forming properties of clinical isolates of Staphylococcus aureus.

    PubMed

    Taj, Yasmeen; Essa, Farhan; Aziz, Faisal; Kazmi, Shahana Urooj

    2012-05-14

    The purpose of this study was to observe the formation of biofilm, an important virulence factor, by isolates of Staphylococcus aureus (S. aureus) in Pakistan by different conventional methods and through electron microscopy. We screened 115 strains of S. aureus isolated from different clinical specimens by tube method (TM), air-liquid interface coverslip assay method, Congo red agar (CRA) method, and scanning electron microscopy (SEM). Out of 115 S. aureus isolates, 63 (54.78%) showed biofilm formation by tube method. Biofilm forming bacteria were further categorized as high producers (n = 23, 20%) and moderate producers (n = 40, 34.78%). TM coordinated well with the coverslip assay for strong biofilm-producing strains in 19 (16.5%) isolates. By coverslip method, weak producers were difficult to differentiate from biofilm negative isolates. Screening on CRA showed biofilm formation only in four (3.47%) strains. Scanning electron micrographs showed the biofilm-forming strains of S. aureus arranged in a matrix on the propylene surface and correlated well with the TM. Biofilm production is a marker of virulence for clinically relevant staphylococcal infections. It can be studied by various methods but screening on CRA is not recommended for investigation of biofilm formation in Staphylococcus aureus. Electron micrograph images correlate well with the biofilm production as observed by TM.

  20. Elicited Speech from Graph Items on the Test of Spoken English[TM]. Research Reports. Report 74. RR-04-06

    ERIC Educational Resources Information Center

    Katz, Irvin R.; Xi, Xiaoming; Kim, Hyun-Joo; Cheng, Peter C. H.

    2004-01-01

    This research applied a cognitive model to identify item features that lead to irrelevant variance on the Test of Spoken English[TM] (TSE[R]). The TSE is an assessment of English oral proficiency and includes an item that elicits a description of a statistical graph. This item type sometimes appears to tap graph-reading skills--an irrelevant…

  1. LANDSAT-D MSS/TM tuned orbital jitter analysis model LDS900

    NASA Technical Reports Server (NTRS)

    Pollak, T. E.

    1981-01-01

    The final LANDSAT-D orbital dynamic math model (LSD900), comprised of all test validated substructures, was used to evaluate the jitter response of the MSS/TM experiments. A dynamic forced response analysis was performed at both the MSS and TM locations on all structural modes considered (thru 200 Hz). The analysis determined the roll angular response of the MSS/TM experiments to improve excitation generated by component operation. Cross axis and cross experiment responses were also calculated. The excitations were analytically represented by seven and nine term Fourier series approximations, for the MSS and TM experiment respectively, which enabled linear harmonic solution techniques to be applied to response calculations. Single worst case jitter was estimated by variations of the eigenvalue spectrum of model LSD 900. The probability of any worst case mode occurrence was investigated.

  2. Theoretical research program to predict the properties of molecules and clusters containing transition metal atoms

    NASA Technical Reports Server (NTRS)

    Walch, S.

    1984-01-01

    The primary focus of this research has been the theoretical study of transition metal (TM) chemistry. A major goal of this work is to provide reliable information about the interaction of H atoms with iron metal. This information is needed to understand the effect of H atoms on the processes of embrittlement and crack propagation in iron. The method in the iron hydrogen studies is the cluster method in which the bulk metal is modelled by a finite number of iron atoms. There are several difficulties in the application of this approach to the hydrogen iron system. First the nature of TM-TM and TM-H bonding for even diatomic molecules was not well understood when these studies were started. Secondly relatively large iron clusters are needed to provide reasonable results.

  3. Hanford's Supplemental Treatment Project: Full-Scale Integrated Testing of In-Container-Vitrification and a 10,000-Liter Dryer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Witwer, K.S.; Dysland, E.J.; Garfield, J.S.

    2008-07-01

    The GeoMelt{sup R} In-Container Vitrification{sup TM} (ICV{sup TM}) process was selected by the U.S. Department of Energy (DOE) in 2004 for further evaluation as the supplemental treatment technology for Hanford's low-activity waste (LAW). Also referred to as 'bulk vitrification', this process combines glass forming minerals, LAW, and chemical amendments; dries the mixture; and then vitrifies the material in a refractory-lined steel container. AMEC Nuclear Ltd. (AMEC) is adapting its GeoMelt ICV{sup TM} technology for this application with technical and analytical support from Pacific Northwest National Laboratory (PNNL). The DVBS project is funded by the DOE Office of River Protection andmore » administered by CH2M HILL Hanford Group, Inc. The Demonstration Bulk Vitrification Project (DBVS) was initiated to engineer, construct, and operate a full-scale bulk vitrification pilot-plant to treat up to 750,000 liters of LAW from Waste Tank 241-S-109 at the DOE Hanford Site. Since the beginning of the DBVS project in 2004, testing has used laboratory, crucible-scale, and engineering-scale equipment to help establish process limitations of selected glass formulations and identify operational issues. Full-scale testing has provided critical design verification of the ICV{sup TM} process before operating the Hanford pilot-plant. In 2007, the project's fifth full-scale test, called FS-38D, (also known as the Integrated Dryer Melter Test, or IDMT,) was performed. This test had three primary objectives: 1) Demonstrate the simultaneous and integrated operation of the ICV{sup TM} melter with a 10,000- liter dryer, 2) Demonstrate the effectiveness of a new feed reformulation and change in process methodology towards reducing the production and migration of molten ionic salts (MIS), and, 3) Demonstrate that an acceptable glass product is produced under these conditions. Testing was performed from August 8 to 17, 2007. Process and analytical results demonstrated that the primary test objectives, along with a dozen supporting objectives, were successfully met. Glass performance exceeded all disposal performance criteria. A previous issue with MIS containment was successfully resolved in FS-38D, and the ICV{sup TM} melter was integrated with a full-scale, 10,000-liter dryer. This paper describes the rationale for performing the test, the purpose and outcome of scale-up tests preceding it, and the performance and outcome of FS-38D. (authors)« less

  4. Evaluation of force released by deflection of orthodontic wires in conventional and self-ligating brackets.

    PubMed

    Higa, Rodrigo Hitoshi; Semenara, Nayara Thiago; Henriques, José Fernando Castanha; Janson, Guilherme; Sathler, Renata; Fernandes, Thais Maria Freire

    2016-01-01

    The aim of the study was to evaluate deflection forces of rectangular orthodontic wires in conventional (MorelliTM), active (In-Ovation RTM) and passive (Damon 3MXTM) self-ligating brackets. Two brands of stainless steel and nickel-titanium (NiTi) wires (MorelliTM and GACTM), in addition to OrmcoTM copper-nickel-titanium wires were used. Specimens were assembled in a clinical simulation device especially designed for this study and tested in an Instron universal testing machine. For the testing procedures, an acrylic structure representative of the maxillary right central incisor was lingually moved in activations of 0 to 1 mm, with readings of the force released by deflection in unloading of 0.5, 0.8 and 1 mm at a constant speed of 2 mm/min. Inter-bracket forces with stainless steel, NiTi and CuNiTi were individually compared by two-way ANOVA, followed by Tukey's tests. Results showed that there were lower forces in conventional brackets, followed by active and passive self-ligating brackets. Within the brands, only for NiTi wires, the MorelliTM brand presented higher forces than GACTM wires. Bracket systems provide different degrees of deflection force, with self-ligating brackets showing the highest forces.

  5. Protocol Development for the NASA-JSC Lunar-Mars Life Support Test Project (LMLSTP) Phase 3 Project: A Report on Baseline Studies at KSC for Continuous Salad Production

    NASA Technical Reports Server (NTRS)

    Goins, G. D.; Yorio, N. C.; Vivenzio, H. R.

    1998-01-01

    The Phase 3 Lunar-Mars Life Support Test Project (LMLSTP) was conducted in a 20-foot chamber at Johnson Space Center. The overall objective of the Phase 3 project was to conduct a 90-day regenerative life support system test involving 4 human subjects to demonstrate an integrated biological and physicochemical life support system. A secondary objective of the Phase 3 LMLSTP was to demonstrate the ability to produce salad-type vegetable by integration of a small benchtop growth chamber located within the crew habitat area. This small chamber, commercially manufactured as the Controlled Environment Research Ecosystem (CERES 2010(TM)), functioned as a means to continuously provide fresh lettuce crops for crew members. The CERES 2010(TM) growth chamber utilized hardware components developed for effective plant biomass production in spaceflight applications. These components included: (1) LED lighting; (2) Astroculture(TM) Root Trays; and (3) Zeoponic media. In planning for the LMLSTP Phase 3, a request was put forward for KSC scientists to generate a protocol for successful continuous planting, culturing, and harvesting of the salad-crop, lettuce. By conducting baseline tests with components of the CERES 2010(TM), a protocol was developed.

  6. Complex thiolated mannose/quinone film modified on EQCM/Au electrode for recognizing specific carbohydrate-proteins.

    PubMed

    Zeng, Hongjuan; Yu, Junsheng; Jiang, Yadong; Zeng, Xiangqun

    2014-05-15

    A complex thiolated mannose (TM)/quinone functionalised polythiophene (QFPT) thin film was modified on EQCM/Au electrode for recognition of specific carbohydrate-proteins. Different lectins such as those from Sambucus nigra (elder berry), Arachis hypogaea (peanut), Ulex europaeus (gorse, furze), Triticum vulgaris and Concanavalin A (ConA) was used for probes to evaluate bio-sensing performance of the TM/QFPT film. A specific response was observed for ConA from lectins when using the TM/QFPT film as sensing material and employing either elelctrochemical or the QCM method. No response was detected between thiolated mannose and other lectins. The linear relationship between current and ConA concentration is in the range of 0.5-17.5 nM by the elelctrochemical method and the linear relationship between frequency change and ConA concentration is in the range of 0.5-4.5 nM by the QCM method. This shows that the TM/QFPT-modified EQCM biosensor presents a paralleled determination by using electrochemical and the QCM method. The elelctrochemical method of the biosensor can be applicable in a large concentration range and its frequency change can be more precise. © 2013 Published by Elsevier B.V.

  7. Response of some Thematic Mapper band ratios to variation in soil water content

    NASA Technical Reports Server (NTRS)

    Musick, H. Brad; Pelletier, Ramona E.

    1986-01-01

    Bidirectional reflectance to nadir in the reflective TM bands and the 1.15-1.3-micron band was measured in the laboratory as moisture content was varied in ten soils. Stronger absorption by water in TM5 and TM7 was expected to cause ratios of other bands to TM5 and TM7 to increase with water content, but in most cases these ratios were constant or decreased at low to intermediate water content and increased only at high moisture levels. Because these ratios were found to decrease as illumination elevation angle decreased, it was suggested that increased roughness resulting from the methods of moistening and mixing the soil may have tended to counteract the expected ratio increases.

  8. Commercialization of Medium Voltage HTS Triax TM Cable Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Knoll, David

    2012-12-31

    The original project scope that was established in 2007 aimed to install a 1,700 meter (1.1 mile) medium voltage HTS Triax{TM} cable system into the utility grid in New Orleans, LA. In 2010, however, the utility partner withdrew from the project, so the 1,700 meter cable installation was cancelled and the scope of work was reduced. The work then concentrated on the specific barriers to commercialization of HTS cable technology. The modified scope included long-length HTS cable design and testing, high voltage factory test development, optimized cooling system development, and HTS cable life-cycle analysis. In 2012, Southwire again analyzed themore » market for HTS cables and deemed the near term market acceptance to be low. The scope of work was further reduced to the completion of tasks already started and to testing of the existing HTS cable system in Columbus, OH. The work completed under the project included: • Long-length cable modeling and analysis • HTS wire evaluation and testing • Cable testing for AC losses • Optimized cooling system design • Life cycle testing of the HTS cable in Columbus, OH • Project management. The 200 meter long HTS Triax{TM} cable in Columbus, OH was incorporated into the project under the initial scope changes as a test bed for life cycle testing as well as the site for an optimized HTS cable cooling system. The Columbus cable utilizes the HTS TriaxTM design, so it provided an economical tool for these of the project tasks.« less

  9. Comparison of tunable lasers based on diode pumped Tm-doped crystals

    NASA Astrophysics Data System (ADS)

    Šulc, Jan; Jelínková, Helena; Koranda, Petr; Černý, Pavel; Jabczyński, Jan K.; Żendzian, Waldemar; Kwiatkowski, Jacek; Urata, Yoshiharu; Higuchi, Mikio

    2008-12-01

    We report on continuously tunable operation of a diode pumped lasers based on Tm-doped materials, emitting in the 1.8 - 2.μ1 m spectral band. In our study we compare results obtained with three various single crystals doped by Tm3+ ions: Yttrium Aluminum perovskite YAP (YAlO3), Gadolinium orthovanadate GdVO4, and Yttrium Lithium Fluoride YLF (YLiF4). Following samples were available: the 3mm long a-cut crystal rod of Tm:YAP with 4% at. Tm/Y (diameter 3 mm); the 8mm long b-cut crystal rod of Tm:YLF with 3.5% at. Tm/Y (diameter 3 mm); the 2.7mm long a-cut crystal block of Tm:GdVO4 with 2% at. Tm/Gd (crystal face 5×3 mm). For active medium pumping, the laser diode radiation was used. Because the tested samples differs significantly in absorption spectra, two fibre-coupled (core diameter 400 µm) temperature-tuned laser diodes were used: first operating at wavelength 793nm was used for Tm:YAP and Tm:YLF; the second operating at wavelength 802nm was used for Tm:GdVO4. In both cases, the continuous power up to 20W was available for pumping. The diode radiation was focused into the active crystal by two achromatic doublet lenses with the focal length f = 75 mm. The measured radius of pumping beam focus inside the crystal was 260 µm. The longitudinally diode pumped crystals were tested in linear, 80mm long, hemispherical laser cavity. The curved (radius 150mm) output coupler reflectivity was ~ 97 % in range from 1.8 up to 2.1 μm. The pumping flat mirror had maximal reflectivity in this range and it had high transmission around 0.8 μm. A 1.5mm thick birefringent plate made from quartz (Lyot filter) inserted under a Brewster's angle was used as a tuning element. This plate was placed inside the resonator between the crystal and the output coupler. Using Tm:YAP crystal, the maximal output power of 2.8W in this set-up was obtained. The laser could be tuned from 1865nm up to 2036nm with a maximum at 1985 nm. Laser based on Tm:YLF crystal was tunable from 1835nm up to 2010nm with a maximum at 1928 nm (3.0W was reached). Using the Tm:GdVO4 tunable operation with greater that 1W output at 1920nm and 130nm tuning range (1842-1972 nm) was demonstrated. The overall reached tuning range of over 200nm covers many important atmospheric absorption lines and contains also the local absorption peak of liquid water, making them attractive for applications such as high resolution spectroscopy, atmospheric remote sensing, laser radar, and laser microsurgery.

  10. Likelihood Ratio Test Polarimetric SAR Ship Detection Application

    DTIC Science & Technology

    2005-12-01

    menu. Under the Matlab menu, the user can export an area of an image to the MatlabTM MAT file format, as well as call RGB image and Pauli...must specify various parameters such as the area of the image to analyze. Export Image Area to MatlabTM (PoIGASP & COASP) Generates a MatlabTM file...represented by the Minister of National Defence, 2005 (0 Sa majest6 la reine, repr(sent(e par le ministre de la Defense nationale, 2005 Abstract This

  11. General Procedure for Protective Cooling and Equipment Evaluations Relative to Heat and Cold Stress

    DTIC Science & Technology

    2008-09-01

    climatic chamber housing the manikin. The most widely accepted test procedures for the operation of a TM are published by the American Society for...describes measurement of the clo value of a complete clothing ensemble. It requires a TM surface temperature of 35ºC and a climatic chamber controlled...Clothing Using a Sweating Manikin” (1) measures the im of a complete clothing ensemble. It requires a TM surface temperature of 35ºC and a climatic

  12. Degree of conversion of nanofilled and microhybrid composite resins photo-activated by different generations of LEDs

    PubMed Central

    RIBEIRO, Benicia Carolina Iaskieviscz; BOAVENTURA, Juliana Maria Capelozza; de BRITO-GONÇALVES, Joel; RASTELLI, Alessandra Nara de Souza; BAGNATO, Vanderlei Salvador; SAAD, José Roberto Cury

    2012-01-01

    Objective This study aimed at evaluating the degree of conversion (DC) of four composite resins, being one nanofilled and 3 microhybrid resins, photo-activated with second- and third-generation light-emitting diodes (LEDs). Material and methods FiltekTM Z350 nanofilled composite resins and Amelogen® Plus, Vit-l-escenceTM and Opallis microhybrid resins were photo-activated with two second-generation LEDs (Radii-cal and Elipar Free LightTM 2) and one third-generation LED (Ultra-Lume LED 5) by continuous light mode, and a quartz halogen-tungsten bulb (QHT, control). After 24 h of storage, the samples were pulverized into fine powder and 5 mg of each material were mixed with 100 mg of potassium bromide (KBr). After homogenization, they were pressed, which resulted in a pellet that was evaluated using an infrared spectromer (Nexus 470, Thermo Nicolet) equipped with TGS detector using diffuse reflectance (32 scans, resolution of 4 cm-1) coupled to a computer. The percentage of unreacted carbon-carbon double bonds (% C=C) was determined from the ratio of absorbance intensities of aliphatic C=C (peak at 1637 cm-1) against internal standard before and after curing of the specimen: aromatic C-C (peak at 1610 cm-1). Results The ANOVA showed a significant effect on the interaction between the light-curing units (LCUs) and the composite resins (p<0.001). The Tukey's test showed that the nanofilled resin (FiltekTM Z350) and Opallis when photo-activated by the halogen lamp (QTH) had the lowest DC compared with the other microhybrid composite resins. The DC of the nanofilled resin (FiltekTM Z350) was also lower using LEDs. The highest degrees of conversion were obtained using the third-generation LED and one of second-generation LEDs (Elipar Free LightTM 2). Conclusions The nanofilled resin showed the lowest DC, and the Vit-l-escenceTM microhybrid composite resin showed the highest DC. Among the LCUs, it was not possible to establish an order, even though the second-generation LED Radii-cal provided the lowest DC. PMID:22666839

  13. Tracheomalacia is associated with lower FEV1 and Pseudomonas acquisition in children with CF

    PubMed Central

    Fischer, Anthony J.; Singh, Sachinkumar B.; Adam, Ryan J.; Stoltz, David A.; Baranano, Christopher F.; Kao, Simon; Weinberger, Miles M.; McCray, Paul B.; Starner, Timothy D.

    2016-01-01

    BACKGROUND Tracheomalacia (TM) occurs in approximately 1 in 2,100 children. Because the trachea develops abnormally in animal models of cystic fibrosis (CF), we hypothesized this may also occur in children with CF, increasing their risk of TM. PURPOSE To examine the prevalence and clinical consequences of TM in children with CF. METHODS We studied children with CF born between 1995 and 2012. TM was defined as dynamic collapse of the trachea, and the severity was recorded as described in the chart. The effect of TM on patient outcomes, including FEV1, CT changes, and acquisition of CF pathogens, was assessed using a longitudinal patient dataset. RESULTS 89% of children with CF had at least one bronchoscopy (n = 97/109). 15% of these children had TM described in any bronchoscopy report (n= 15/97). Of the patients with TM, 8 had meconium ileus (p = 0.003) and all were pancreatic insufficient. Pseudomonas aeruginosa infection occurred 1.3 years earlier among children with TM (p = 0.01). Starting FEV1 values by age 8 were diminished by over 18% of predicted for patients with TM. Life-threatening episodes of airway obstruction occurred in 3 of 15 patients with CF and TM, including one leading to death. Gender, prematurity, and hepatic disease were not associated with TM. No difference was observed in the frequency of bronchiectasis. CONCLUSIONS TM is significantly more common in infants and children with CF than in the general population and is associated with airway obstruction and earlier Pseudomonas acquisition. PMID:24166775

  14. A review of translational medicine. The future paradigm: how can we connect the orthopedic dots better?

    PubMed

    Mediouni, Mohamed; R Schlatterer, Daniel; Madry, Henning; Cucchiarini, Magali; Rai, Balwant

    2017-11-01

    Patients with complex medical and surgical problems often travel great distances to prestigious university medical centers in search of solutions and in some cases for nothing more than a diagnosis of their condition. Translational medicine (TM) is an emerging method and process of facilitating medical advances efficiently from the scientist to the clinician. Most established clinicians and those in training know very little about this new discipline. The purpose of this article is to illustrate TM in varied scientific, medical and surgical fields. Anecdotal events in medicine and orthopaedics based upon a practicing orthopaedic surgeon's training and clinical experience are presented. TM is rapidly assuming a greater presence in the medical community. The National Institute of Health (NIH) recognizes this discipline and has funded TM projects. Numerous institutions in Europe and the USA offer advanced degrees in TM. Finally there is a European Society for Translational Medicine (EUTMS), an International Society for Translational Medicine, and an Academy of Translational Medical Professionals (ATMP). The examples of TM presented in this article support the argument for the formation of more TM networks on the local and regional levels. The need for increased participation of researchers and clinicians requires further study to identify the economic and social impact of TM. The examples of TM presented in this article support the argument for the formation of more TM networks on the local and regional levels. Financial constraints for TM can be overcome by pooling government, academic, private, and industry resources in an organized fashion with oversight by a lead TM researcher.

  15. A novel method for quantifying the amount of trabecular meshwork pigment in glaucomatous and nonglaucomatous eyes.

    PubMed

    Kinori, Michael; Hostovsky, Avner; Skaat, Alon; Schwartsman, Jonathan; Melamed, Shlomo

    2014-01-01

    To assess the use of a computerized program for evaluating the amount of trabecular meshwork (TM) pigmentation in normal (control), primary open-angle glaucoma (POAG), and pseudoexfoliation glaucoma/pigmentary dispersion glaucoma (PXFG/PDG) patients. All included patients were from the Goldschleger Eye Institute glaucoma clinic. After signing an informed consent, each patient's anterior chamber angle was photographed using a single photo-slit under the same conditions. Only one eye per patient was photographed. The superior TM and the inferior TM were documented. Then, the degree of "blackness" (representing melanin pigment) was assessed using the ImageJ program. Of the 43 eyes photographed, 8 were excluded because of low-quality images. Of the remaining 35 patients, 14 were normal, 10 had POAG, and 11 had PXFG/PDG. The amount of pigment was the same in the control and the POAG patients whether the inferior TM (P=0.24), superior TM (P=0.58), or the sum inferior TM+superior TM (P=0.85) was measured. The pigment level was significantly higher in the PXFG/PDG group than in the control group (inferior TM, P<0.01; superior TM, P=0.047; sum, P<0.01). The difference between the inferior and the superior TM pigment levels was found to be statistically insignificant in all the groups (normal, P=0.86; POAG, P=0.10; PXFG/PDG, P=0.22). The use of ImageJ software might play a role in the quantification of pigment evaluation of the TM.

  16. Statistical analyses and computational prediction of helical kinks in membrane proteins

    NASA Astrophysics Data System (ADS)

    Huang, Y.-H.; Chen, C.-M.

    2012-10-01

    We have carried out statistical analyses and computer simulations of helical kinks for TM helices in the PDBTM database. About 59 % of 1562 TM helices showed a significant kink, and 38 % of these kinks are associated with prolines in a range of ±4 residues. Our analyses show that helical kinks are more populated in the central region of helices, particularly in the range of 1-3 residues away from the helix center. Among 1,053 helical kinks analyzed, 88 % of kinks are bends (change in helix axis without loss of helical character) and 12 % are disruptions (change in helix axis and loss of helical character). It is found that proline residues tend to cause larger kink angles in helical bends, while this effect is not observed in helical disruptions. A further analysis of these kinked helices suggests that a kinked helix usually has 1-2 broken backbone hydrogen bonds with the corresponding N-O distance in the range of 4.2-8.7 Å, whose distribution is sharply peaked at 4.9 Å followed by an exponential decay with increasing distance. Our main aims of this study are to understand the formation of helical kinks and to predict their structural features. Therefore we further performed molecular dynamics (MD) simulations under four simulation scenarios to investigate kink formation in 37 kinked TM helices and 5 unkinked TM helices. The representative models of these kinked helices are predicted by a clustering algorithm, SPICKER, from numerous decoy structures possessing the above generic features of kinked helices. Our results show an accuracy of 95 % in predicting the kink position of kinked TM helices and an error less than 10° in the angle prediction of 71.4 % kinked helices. For unkinked helices, based on various structure similarity tests, our predicted models are highly consistent with their crystal structure. These results provide strong supports for the validity of our method in predicting the structure of TM helices.

  17. Yb3+ sensitized Tm3+ upconversion in tellurite lead oxide glass.

    PubMed

    Mohanty, Deepak Kumar; Rai, Vineet Kumar; Dwivedi, Y

    2012-04-01

    Triply ionized thulium/thulium--ytterbium doped/codoped TeO2-Pb3O4 (TPO) glasses have been fabricated by classical quenching method. The upconversion emission spectra in the Tm3+/Tm3+-Yb3+ doped/codoped glasses upon excitation with a diode laser lasing at ∼980 nm has been studied. Effect of the addition of the Yb3+ on the upconversion emission intensity in the visible and near infrared regions of the Tm3+ doped in TPO glass has been studied and the processes involved explored. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. [Establishment and verification of detecting multiple biomarkers for ovarian cancer by suspension array technology].

    PubMed

    Zhao, B B; Yang, Z J; Wang, Q; Pan, Z M; Zhang, W; Li, D R; Li, L

    2016-10-25

    Objective: Establish and validation of combined detecting of CCL18, CXCL1, C1D, TM4SF1, FXR1, TIZ suspension array technology. Methods: (1)CCL18, CXCL1 monoclonal antibody and C1D, TM4SF1, FXR1, TIZ protein were coupled with polyethylene microspheres. Biotinylated CCL18, CXCL1 polyclonal antibody and sheep anti-human IgG polyclonal antibody were prepared simultaneously. The best packaged concentrations of CCL18, CXCL1 monoclonal antibody and C1D, TM4SF1, FXR1, TIZ antigens were optimized. The best packaged concentrations of CCL18, CXCL1 polyclonal antibodys and C1D, TM4SF1, FXR1, TIZ sheep anti-human IgG polyclonal antibody were optimized to establish a stable detected suspension array.(2)Sixty patients confirmed by pathological examination with ovarian cancer(ovarian cancer group)which treated in Affiliated Tumor Hospital of Guangxi Medical University, 30 patients with ovarian benign tumor(benign group)and 30 cases of healthy women(control group)were chosen between September 2003 and December 2003. Suspension array technology and ELISA method were used to detect expression of CCL18, CXCL1 antigen and C1D, TM4SF1, FXR1 and TIZ IgG autoantibody contented in 3 groups of serum, then to compare the diagnostic efficiency and diagnostic accuracy of two methods(coefficient of variation between batch and batch). Results: (1)This research successfully established stable detecting system of CCL18, CXCL1, C1D, TM4SF1, FXR1 and TIZ IgG autoantibody. The best concentration of CCL18, CXCL1 monoclonal antibody and C1D, TM4SF1, FXR1, TIZ antigen package were 8, 8, 12, 8, 4 and 8 μg/ml; the best detection of CCL18, CXCL1 biotin polyclonal antibody and C1D, TM4SF1, FXR1, TIZ sheep anti-huamne IgG polyclonal antibody were respectively 4, 2, 2, 4, 4 and 2 μg/ml.(2)Suspension array technology and ELISA method were used to detect CCL18, CXCL1 antigen and C1D, TM4SF1, FXR1, TIZ IgG autoantibody of three groups in serum were similar( P >0.05).(3)The comparison of two methods in the diagnosis of efficiency: the diagnostic accuracy of two methods were 99.2%(119/120)and 94.2%(113/120), the difference was statistically significant( P =0.031). The sensitivity of the diagnosis of ovarian cancer of two methods were 100.0%(60/60)and 93.3%(56/60), specific degrees were 100.0%(59/59)and 93.4%(57/61), positive predictive value was 100.0%(60/60)and 93.3%(56/60), negative predictive value was 98.3%(59/60)and 95.0%(57/60), the difference was statistically significant( P <0.05).(4)The detected results of CCL18, CXCL1 antigen and C1D, TM4SF1, FXR1, TIZ IgG autoantibody shown that the diagnostic accuracy of suspension array technology was superior to those of ELISA method(all P <0.05). Conclusion: The study has established the stable detection of suspension array technology, and the diagnostic efficiency and diagnostic accuracy was much better than that by ELISA.

  19. Enhanced Photoluminescent Properties and Crystalline Morphology of LiBaPO4:Tm3+ Phosphor through Microwave Sintering Method

    PubMed Central

    Lai, Hsuan-Lin; Weng, Min-Hang; Yang, Ru-Yuan; Chang, Shoou-Jinn

    2016-01-01

    An investigation of the photoluminescent properties and crystalline morphology of blue emitting LiBa1−xPO4:xTm3+ phosphors with various concentrations (x = 0.005–0.030) of Tm3+ ions were synthesized by microwave sintering. For comparison, the LiBa1−xPO4:xTm3+ powders sintered at the same sintering condition but in a conventional furnace were also investigated. LiBaPO4 without second phase was formed no matter which furnace was used. More uniform grain size distributions are obtained by microwave sintering. When the concentration of Tm3+ ion was x = 0.015, the luminescence intensity reached a maximum value, and then decreased with the increases of the Tm3+ concentration due to concentration quenching effect. The microwave sintering significantly enhanced the emission intensity of LiBa1−xPO4:xTm3+ phosphors. Additionally, the d-d interaction is the key mechanism of concentration quenching for LiBaPO4:Tm3+. The chromaticity (x, y) for all LiBa1−xPO4:xTm3+ phosphors are located at (0.16, 0.05), which will be classified as a blue region. PMID:28773483

  20. Tunable luminescence mediated by energy transfer in Tm3+/Dy3+ co-doped phosphate glasses under UV excitation

    NASA Astrophysics Data System (ADS)

    Chen, Yong; Chen, Guohua; Liu, Xiangyu; Yuan, Changlai; Zhou, Changrong

    2017-11-01

    Tm3+/Dy3+ co-doped phosphate glasses for white light-emitting diodes were synthesized by a conventional melting-quenching method. A spectroscopic research based on optical, photoluminescence spectrum and decay time curves in Tm3+/Dy3+ co-doped phosphate glasses was carried out. The color of luminescence could be tuned by altering the concentrations of Tm3+ ions. Under UV light excitation, the CIE chromaticity coordinates (0.3471, 0.3374) and color correlate temperature (CCT = 4866.21 K) close to the standard white-light illumination (0.333, 0.333 and CCT = 5454.12 K) could be achieved in 0.4 Tm3+/0.6 Dy3+ (mol %) co-doped glass sample. The decrease of the Dy3+ emission decay time in existence of Tm3+ ascertained that non-radiative energy transfer from Dy3+ to Tm3+ occurred. Moreover, the research of energy transfers between Dy3+ and Tm3+ based on the Inokuti-Hirayama model revealed that an electric quadrupole-quadrupole interaction might be the predominant mechanism participated in the energy transfer. This finding suggests that the as-prepared Tm3+/Dy3+ co-doped phosphate glasses may be promising candidate for white LEDs and other display devices.

  1. Analysis of LANDSAT-4 TM Data for Lithologic and Image Mapping Purpose

    NASA Technical Reports Server (NTRS)

    Podwysocki, M. H.; Salisbury, J. W.; Bender, L. V.; Jones, O. D.; Mimms, D. L.

    1984-01-01

    Lithologic mapping techniques using the near infrared bands of the Thematic Mapper onboard the LANDSAT 4 satellite are investigated. These methods are coupled with digital masking to test the capability of mapping geologic materials. Data are examined under medium to low Sun angle illumination conditions to determine the detection limits of materials with absorption features. Several detection anomalies are observed and explained.

  2. Spectroscopic properties of Tm3+/Al3+ co-doped sol-gel silica glass

    NASA Astrophysics Data System (ADS)

    Wang, Xue; Lou, Fengguang; Wang, Shikai; Yu, Chunlei; Chen, Danping; Hu, Lili

    2015-04-01

    Tm3+/Al3+ co-doped silica glass was prepared by sol-gel method combined with high temperature sintering. Glasses with compositions of xTm2O3-15xAl2O3-(100 - 16x) SiO2 (in mol%, x = 0.1, 0.3, 0.5, 0.8 and 1.0) were prepared. The high thulium doped silica glass was realized. Their spectroscopic parameters were calculated and analyzed by Judd-Ofelt theory. Large absorption cross section (4.65 × 10-21 cm2 at 1668 nm) and stimulated emission cross section (6.00 × 10-21 cm2 at 1812 nm), as well as low hydroxyl content (0.180 cm-1), long fluorescence lifetime (834 μs at 1800 nm), large σem × τrad (30.05 × 10-21 cm2 ms) and large relative intensity ratio of the 1.8 μm (3F4 → 3H6) to 1.46 (3H4 → 3F4) emissions (90.33) are achieved in this Tm3+/Al3+ co-doped silica glasses. According to emission characteristics, the optimum thulium doping concentration is around 0.8 mol%. The cross relaxation (CR) between ground and excited states of Tm3+ ions was used to explain the optimum thulium doping concentration. These results suggest that the sol-gel method is an effective way to prepare Tm3+ doped silica glass with high Tm3+ doping and prospective spectroscopic properties.

  3. Hold the Applause!: Do Accelerated Reader (TM) and Electronic Bookshelf (TM) Send the Right Message?

    ERIC Educational Resources Information Center

    Carter, Betty

    1996-01-01

    Although the computerized reading management programs, Accelerated Reader and Electronic Bookshelf, increase library circulation and standardized test scores, they have drawbacks. Both programs devalue reading, diminish motivation, limit title choice, restrict materials selection and collection development, discourage independent selection of…

  4. LANDSAT-4 MSS and Thematic Mapper data quality and information content analysis

    NASA Technical Reports Server (NTRS)

    Anuta, P.; Bartolucci, L.; Dean, E.; Lozano, F.; Malaret, E.; Mcgillem, C. D.; Valdes, J.; Valenzuela, C.

    1984-01-01

    LANDSAT-4 thematic mapper (TM) and multispectral scanner (MSS) data were analyzed to obtain information on data quality and information content. Geometric evaluations were performed to test band-to-band registration accuracy. Thematic mapper overall system resolution was evaluated using scene objects which demonstrated sharp high contrast edge responses. Radiometric evaluation included detector relative calibration, effects of resampling, and coherent noise effects. Information content evaluation was carried out using clustering, principal components, transformed divergence separability measure, and supervised classifiers on test data. A detailed spectral class analysis (multispectral classification) was carried out to compare the information content of the MSS and TM for a large number of scene classes. A temperature-mapping experiment was carried out for a cooling pond to test the quality of thermal-band calibration. Overall TM data quality is very good. The MSS data are noisier than previous LANDSAT results.

  5. 2-micron lasing in Tm:Lu2O3 ceramic: initial operation

    NASA Astrophysics Data System (ADS)

    Vetrovec, John; Filgas, David M.; Smith, Carey A.; Copeland, Drew A.; Litt, Amardeep S.; Briscoe, Eldridge; Schirmer, Ernestina

    2018-03-01

    We report on initial lasing of Tm:Lu2O3 ceramic laser with tunable output in the vicinity of 2 μm. Tm:Lu2O3 ceramic gain materials offer a much lower saturation fluence than the traditionally used Tm:YLF and Tm:YAG materials. The gain element is pumped by 796 nm diodes via a "2-for-1" crossrelaxation energy transfer mechanism, which enables high efficiency. The high thermal conductivity of the Lu2O3 host ( 18% higher than YAG) in combination with low quantum defect of 20% supports operation at high-average power. Konoshima's ceramic fabrication process overcomes the scalability limits of single crystal sesquioxides. Tm:Lu2O3 offers wide-bandwidth amplification of ultrashort pulses in a chirped-pulse amplification (CPA) system. A laser oscillator was continuously tuned over a 230 nm range from 1890 to 2120 nm while delivering up to 43W QCW output with up to 37% efficiency. This device is intended for initial testing and later seeding of a multi-pass edge-pumped disk amplifier now being developed by Aqwest which uses composite Tm:Lu2O3 disk gain elements.

  6. Comparison of telemedicine with in-person care for follow-up after elective neurosurgery: results of a cost-effectiveness analysis of 1200 patients using patient-perceived utility scores.

    PubMed

    Thakar, Sumit; Rajagopal, Niranjana; Mani, Subramaniyan; Shyam, Maya; Aryan, Saritha; Rao, Arun S; Srinivasa, Rakshith; Mohan, Dilip; Hegde, Alangar S

    2018-05-01

    OBJECTIVE The utility of telemedicine (TM) in neurosurgery is underexplored, with most of the studies relating to teletrauma or telestroke programs. In this study, the authors evaluate the cost-effectiveness of TM consultations for follow-up care of a large population of patients who underwent neurosurgical procedures. METHODS A decision-analytical model was used to assess the cost-effectiveness of TM for elective post-neurosurgical care patients from a predominantly nonurban cohort in West Bengal, India. The model compared TM care via a nodal center in West Bengal to routine, in-person, per-episode care at the provider site in Bangalore, India. Cost and effectiveness data relating to 1200 patients were collected for a 52-month period. The effectiveness of TM care was calculated using efficiency in terms of the percentage of successful TM consultations, as well as patient-perceived utility values for overall experience of the type of health care access that they received. Incremental cost-effectiveness ratio (ICER) analysis was done using the 4-quadrant charting of the cost-effectiveness plane. One-way sensitivity and tornado analyses were performed to identify thresholds where the care strategy would change. RESULTS The overall utility for the 3 TM scenarios was found to be higher (89%) than for the utility of routine care (80%). TM was found to be more cost-effective (Indian rupee [INR] 2630 per patient) compared to routine care (INR 6848 per patient). The TM strategy "dominates" that of routine care by being more effective and less expensive (ICER value of -39,400 INR/unit of effectiveness). Sensitivity analysis revealed that cost-effectiveness of TM was most sensitive to changes in the number of TM patients, utility and success rate of TM, and travel distance to the TM center. CONCLUSIONS TM care dominates the in-person care strategy by providing more effective and less expensive follow-up care for a remote post-neurosurgical care population in India. In the authors' setting, this benefit of TM is sustainable even if half the TM consultations turn out to be unsuccessful. The viability of TM as a cost-effective care protocol is attributed to a combination of factors, like an adequate patient volume utilizing TM, patient utility, success rate of TM, and the patient travel distance.

  7. Telangiectatic Matting is Associated with Hypersensitivity and a Bleeding Tendency.

    PubMed

    Kadam, Pooja; Lim, Jerrick; Paver, Ian; Connor, David E; Parsi, Kurosh

    2018-04-01

    The aim was to investigate the pathogenesis of telangiectatic matting (TM) and identify possible risk factors. This study had two parts. The clinical records of consecutive patients were retrospectively analysed to identify risk factors for TM. In the second part, the haemostatic and coagulation profile of the subset of patients with TM were analysed and compared with controls using standard coagulation tests, platelet function and a global assay of coagulation (rotational thromboelastometry, ROTEM). In 352 consecutive patients presenting to a phlebology practice, 25 patients had TM (7.1%). All 25 patients were female with the median age of 45 (27-57) years. A comprehensive medical history was taken. Among 27 possible risk factors assessed, statistically significant associations included recurrent epistaxis, easy bruising, hypersensitivity (eczema, hives, hay fever, and rhinitis), previous treatment with sclerotherapy or endovenous laser for lower limb veins, and a family history of telangiectasias. Variables not associated with TM included oral contraceptive intake, hormone replacement therapy, and age. The haemostatic and coagulation profile of 12 patients (6 male and 6 female) with TM did not differ significantly from those without TM. TM is associated with both hypersensitivity and a bleeding tendency. This study revealed no significant increase in the incidence of haemostatic abnormalities in patients with TM compared with the control group. Given the significant association with hypersensitivity disorders, the underlying mast cell hyper-reactivity may contribute to both hypersensitivity and a bleeding tendency and predispose patients to TM. Copyright © 2017 European Society for Vascular Surgery. Published by Elsevier B.V. All rights reserved.

  8. LANDSAT-D Investigations Workshop

    NASA Technical Reports Server (NTRS)

    1982-01-01

    The objectives and methods used to determine the performance of the LANDSAT-D thematic mapper radiometric and geometric sensors are depicted in graphs and charts. Other aspects illustrated include ground and flight segment TM geometric processing and early access TM processing.

  9. Laparoscopic lens fogging: solving a common surgical problem in standard and robotic laparoscopes via a scientific model.

    PubMed

    Manning, Todd G; Papa, Nathan; Perera, Marlon; McGrath, Shannon; Christidis, Daniel; Khan, Munad; O'Beirne, Richard; Campbell, Nicholas; Bolton, Damien; Lawrentschuk, Nathan

    2018-03-01

    Laparoscopic lens fogging (LLF) hampers vision and impedes operative efficiency. Attempts to reduce LLF have led to the development of various anti-fogging fluids and warming devices. Limited literature exists directly comparing these techniques. We constructed a model peritoneum to simulate LLF and to compare the efficacy of various anti-fogging techniques. Intraperitoneal space was simulated using a suction bag suspended within an 8 L container of water. LLF was induced by varying the temperature and humidity within the model peritoneum. Various anti-fogging techniques were assessed including scope warmers, FRED TM , Resoclear TM , chlorhexidine, betadine and immersion in heated saline. These products were trialled with and without the use of a disposable scope warmer. Vision scores were evaluated by the same investigator for all tests and rated according to a predetermined scale. Fogging was assessed for each product or technique 30 times and a mean vision rating was recorded. All products tested imparted some benefit, but FRED TM performed better than all other techniques. Betadine and Resoclear TM performed no better than the use of a scope warmer alone. Immersion in saline prior to insertion resulted in decreased vision ratings. The robotic scope did not result in LLF within the model. In standard laparoscopes, the most superior preventative measure was FRED TM utilised on a pre-warmed scope. Despite improvements in LLF with other products FRED TM was better than all other techniques. The robotic laparoscope performed superiorly regarding LLF compared to standard laparoscope.

  10. The rat ErbB2 tyrosine kinase receptor produced in plants is immunogenic in mice and confers protective immunity against ErbB2(+) mammary cancer.

    PubMed

    Matić, Slavica; Quaglino, Elena; Arata, Lucia; Riccardo, Federica; Pegoraro, Mattia; Vallino, Marta; Cavallo, Federica; Noris, Emanuela

    2016-01-01

    The rat ErbB2 (rErbB2) protein is a 185-kDa glycoprotein belonging to the epidermal growth factor-related proteins (ErbB) of receptor tyrosine kinases. Overexpression and mutations of ErbB proteins lead to several malignancies including breast, lung, pancreatic, bladder and ovary carcinomas. ErbB2 is immunogenic and is an ideal candidate for cancer immunotherapy. We investigated the possibility of expressing the extracellular (EC) domain of rErbB2 (653 amino acids, aa) in Nicotiana benthamiana plants, testing the influence of the 23 aa transmembrane (TM) sequence on protein accumulation. Synthetic variants of the rErbB2 gene portion encoding the EC domain, optimized with a human codon usage and either linked to the full TM domain (rErbB2_TM, 676 aa), to a portion of it (rErbB2-pTM, 662 aa), or deprived of it (rErbB2_noTM, 653 aa) were cloned in the pEAQ-HT expression vector as 6X His tag fusions. All rErbB2 variants (72-74.5 kDa) were transiently expressed, but the TM was detrimental for rErbB2 EC accumulation. rERbB2_noTM was the most expressed protein; it was solubilized and purified with Nickel affinity resin. When crude soluble extracts expressing rErbB2_noTM were administered to BALB/c mice, specific rErbB2 immune responses were triggered. A potent antitumour activity was induced when vaccinated mice were challenged with syngeneic transplantable ErbB2(+) mammary carcinoma cells. To our knowledge, this is the first report of expression of rErbB2 in plants and of its efficacy in inducing a protective antitumour immune response, opening interesting perspectives for further immunological testing. © 2015 Society for Experimental Biology, Association of Applied Biologists and John Wiley & Sons Ltd.

  11. TE/TM decomposition of electromagnetic sources

    NASA Technical Reports Server (NTRS)

    Lindell, Ismo V.

    1988-01-01

    Three methods are given by which bounded EM sources can be decomposed into two parts radiating transverse electric (TE) and transverse magnetic (TM) fields with respect to a given constant direction in space. The theory applies source equivalence and nonradiating source concepts, which lead to decomposition methods based on a recursive formula or two differential equations for the determination of the TE and TM components of the original source. Decompositions for a dipole in terms of point, line, and plane sources are studied in detail. The planar decomposition is seen to match to an earlier result given by Clemmow (1963). As an application of the point decomposition method, it is demonstrated that the general exact image expression for the Sommerfeld half-space problem, previously derived through heuristic reasoning, can be more straightforwardly obtained through the present decomposition method.

  12. Combined use of chiral ionic liquid and cyclodextrin for MEKC: Part I. Simultaneous enantioseparation of anionic profens

    PubMed Central

    Wang, Bin; He, Jun; Bianchi, Victoria; Shamsi, Shahab A.

    2009-01-01

    The enantiomers of five profen (PROF) drugs were simultaneously separated by MEKC with the combined use of 2, 3, 6-tri-O-methyl-β-cyclodextrin (TM-β-CD) and chiral cationic ionic liquid (IL), N-undecenoxy-carbonyl-L-leucinol bromide (L-UCLB), which formed micelles in aqueous buffers. Enantioseparations of these PROF drugs were optimized by varying the chain length and concentration of the IL surfactant using a standard recipe containing 35 mM TM-β-CD, 5 mM sodium acetate at pH 5.0. The batch-to-batch reproducibility of L-UCLB was tested and found to have no significant impact in terms of enantiomeric resolution, efficiency and migration time. Finally, this method was successfully applied for the quantitative determination of ibuprofen in pharmaceutical tablets. PMID:19650046

  13. Prediction of pavement remaining service life based on repetition of load and permanent deformation

    NASA Astrophysics Data System (ADS)

    Usman, R. S.; Setyawan, A.; Suprapto, M.

    2018-03-01

    One of the methods which was applied in the assessment of flexible pavement performance was mechanistic method assuming structures of road pavement to become multi-layer structure for flexible pavement, that the vehicle load working on the pavement layer under repetition with power failure worth 1 (one) unit which was assumed as evenly distributed static load, and therefore the pavement material would provide response in the form of stress, strain, and deflection. This is closely related in order to assess the structure of flexible pavement and to predict the remaining service life on the roads of Pulau Indah sta 0 + 000 to sta. 0 + 845 in Kota Kupang, Nusa Tenggara Timur. The performance appraisal indicator which was used was fatigue cracking happening bottom of the asphalt layer and permanent deformation (rutting) on the surface of subgrade. The strain estimate on the flexible pavement layer structure needs carefulness and high accuracy and therefore a software like KENPAVE which produces horizontal tensile strain of 8,802E-05 and vertical compressive strain of 2,642E-04 was used. By applying equation of The Asphalt Instituteit was obtained repetition of permit load when reaching fatigue cracking (Nf) was 16.071.516 ESAL and permanent deformation (rutting) was 14.703.867 ESAL and also it was predicted the remaining service life of pavement applied the equation of AASTHO 1993 by considering Traffic Multiplier factor (TM 1.8, TM 1.9 and TM 2.0) obtained the remaining life service due to fatigue of 5.51% in the year of 13th (TM 1.8), 7.95% in the year of12th (TM 1.9) and 3.11% (TM 2.0) in the year of 12th, also the remaining service life due to rutting of 4.69% in the year of 12th(TM 1.8), 7.79% in the year of 11th (TM 1.9), and 2.94 in the year of 11th (TM 2.0).

  14. Temperature measurement in the adult emergency department: oral, tympanic membrane and temporal artery temperatures versus rectal temperature.

    PubMed

    Bijur, Polly E; Shah, Purvi D; Esses, David

    2016-12-01

    The objective was to compare agreement between three non-invasive measures of temperature and rectal temperatures and to estimate the sensitivity and specificity of these measures to detect a rectal temperature of 38°C or higher. We conducted a study of the diagnostic accuracy of oral, tympanic membrane (TM) and temporal artery (TA) thermometry to measure fever in an urban emergency department (ED). Data were collected from adult patients who received rectal temperature measurement. Bland-Altman analysis was performed; sensitivity, specificity and 95% CIs were calculated. 987 patients were enrolled. 36% of the TM and TA readings differed by 0.5°C or more from rectal temperatures, 50% of oral temperatures. TM measures were most precise-the SD of the difference from rectal was 0.4°C TM, and 0.6°C for oral and TA (p<0.001). The sensitivities of a 38°C cutpoint on oral, TM and TA measures to detect a rectal temperature of 38°C or higher were: 37.0%, 68.3% and 71.1%, respectively (oral vs TM and TA p<0.001). The corresponding specificities were 99.4%, 98.2% and 92.3% (oral, TM and TA) with oral specificity significantly higher than the other two methods (p<0.01). TM and TA cutpoints of 37.5°C provided greater than 90% sensitivity to detect fever with specificity of 90% and 72%, respectively. None of the non-invasive methods met benchmarks for diagnostic accuracy using the criterion of 38°C to detect rectal temperature of 38°C. A TM cutpoint of 37.5°C provides maximum diagnostic accuracy of the three non-invasive measures. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  15. Transmembrane protein topology prediction using support vector machines.

    PubMed

    Nugent, Timothy; Jones, David T

    2009-05-26

    Alpha-helical transmembrane (TM) proteins are involved in a wide range of important biological processes such as cell signaling, transport of membrane-impermeable molecules, cell-cell communication, cell recognition and cell adhesion. Many are also prime drug targets, and it has been estimated that more than half of all drugs currently on the market target membrane proteins. However, due to the experimental difficulties involved in obtaining high quality crystals, this class of protein is severely under-represented in structural databases. In the absence of structural data, sequence-based prediction methods allow TM protein topology to be investigated. We present a support vector machine-based (SVM) TM protein topology predictor that integrates both signal peptide and re-entrant helix prediction, benchmarked with full cross-validation on a novel data set of 131 sequences with known crystal structures. The method achieves topology prediction accuracy of 89%, while signal peptides and re-entrant helices are predicted with 93% and 44% accuracy respectively. An additional SVM trained to discriminate between globular and TM proteins detected zero false positives, with a low false negative rate of 0.4%. We present the results of applying these tools to a number of complete genomes. Source code, data sets and a web server are freely available from http://bioinf.cs.ucl.ac.uk/psipred/. The high accuracy of TM topology prediction which includes detection of both signal peptides and re-entrant helices, combined with the ability to effectively discriminate between TM and globular proteins, make this method ideally suited to whole genome annotation of alpha-helical transmembrane proteins.

  16. High-speed holographic system for full-field transient vibrometry of the human tympanic membrane

    NASA Astrophysics Data System (ADS)

    Dobrev, I.; Harrington, E. J.; Cheng, T.; Furlong, C.; Rosowski, J. J.

    2014-07-01

    Understanding of the human hearing process requires the quantification of the transient response of the human ear and the human tympanic membrane (TM or eardrum) in particular. Current state-of-the-art medical methods to quantify the transient acousto-mechanical response of the TM provide only averaged acoustic or local information at a few points. This may be insufficient to fully describe the complex patterns unfolding across the full surface of the TM. Existing engineering systems for full-field nanometer measurements of transient events, typically based on holographic methods, constrain the maximum sampling speed and/or require complex experimental setups. We have developed and implemented of a new high-speed (i.e., > 40 Kfps) holographic system (HHS) with a hybrid spatio-temporal local correlation phase sampling method that allows quantification of the full-field nanometer transient (i.e., > 10 kHz) displacement of the human TM. The HHS temporal accuracy and resolution is validated versus a LDV on both artificial membranes and human TMs. The high temporal (i.e., < 24 μs) and spatial (i.e., >100k data points) resolution of our HHS enables simultaneous measurement of the time waveform of the full surface of the TM. These capabilities allow for quantification of spatially-dependent motion parameters such as energy propagation delays surface wave speeds, which can be used to infer local material properties across the surface of the TM. The HHS could provide a new tool for the investigation of the auditory system with applications in medical research, in-vivo clinical diagnosis as well as hearing aids design.

  17. Comparative Evaluation of Marginal Adaptation of BiodentineTM and Other Commonly Used Root End Filling Materials-An Invitro Study

    PubMed Central

    P.V., Ravichandra; Vemisetty, Harikumar; K., Deepthi; Reddy S, Jayaprada; D., Ramkiran; Krishna M., Jaya Nagendra; Malathi, Gita

    2014-01-01

    Aim: The purpose of this investigation was to evaluate the marginal adaptation of three root-end filling materials Glass ionomer cement, Mineral trioxide aggregate and BiodentineTM. Methodology: Thirty human single-rooted teeth were resected 3 mm from the apex. Root-end cavities were then prepared using an ultrasonic tip and filled with one of the following materials Glass ionomer cement (GIC), Mineral trioxide aggregate (MTA) and a bioactive cement BiodentineTM. The apical portions of the roots were then sectioned to obtain three 1 mm thick transversal sections. Confocal laser scanning microscopy (CLSM) was used to determine area of gaps and adaptation of the root-end filling materials with the dentin. The Post hoc test, a multiple comparison test was used for statistical data analysis. Results: Statistical analysis showed lowest marginal gaps (11143.42±967.753m2) and good marginal adaptation with BiodentineTM followed by MTA (22300.97±3068.883m2) and highest marginal gaps with GIC (33388.17±12155.903m2) which were statistically significant (p<0.0001). Conclusion: A new root end filling material BiodentineTM showed better marginal adaptation than commonly used root end filling materials PMID:24783148

  18. Session RPE and salivary immune-endocrine responses to simulated and official basketball matches in elite young male athletes.

    PubMed

    Moreira, A; Crewther, B; Freitas, C G; Arruda, A F S; Costa, E C; Aoki, M S

    2012-12-01

    The present study compared the ratings of perceived exertion (RPE) and immune-endocrine (IgA and cortisol) responses to simulated training matches (TM) and official matches (OM) in elite young male basketball players (N.=10). Saliva samples were collected from each player before and after three TM and two OM and subsequently tested for cortisol and IgA concentrations by immunoassay. The perceived intensity of each match was rated using a RPE scale (CR-10). The training match and official match data were pooled to provide an aggregate value for each setting. The session RPE scores from the OM were significantly (P<0.05) greater than the simulated TM. Pre- and postcortisol concentrations assessed during the OM were also found to be significantly higher than the TM (P<0.05). No significant changes in salivary IgA concentrations were observed across either the simulated or official match settings. In summary, the OM induced greater RPE and salivary cortisol responses than the simulated TM, probably due to the additional stressors associated with real competition. The data also suggests that acute changes in cortisol concentrations do not play a role in the regulation of salivary IgA under the current testing conditions.

  19. Investigation of biofilm formation on contact eye lenses caused by methicillin resistant Staphylococcus aureus.

    PubMed

    Khalil, M A; Sonbol, F I

    2014-01-01

    The objective was to investigate the biofilm-forming capacity of methicillin resistant Staphylococcus aureus (MRSA) isolated from eye lenses of infected patients. A total of 32 MRSA isolated from contact lenses of patients with ocular infections were screened for their biofilm-forming capacity using tube method (TM), Congo red agar (CRA), and microtiter plate (MtP) methods. The effect of some stress factor on the biofilm formation was studied. The biofilm-forming related genes, icaA, icaD and 10 microbial surface components that recognize adhesive matrix molecule (MSCRAMM), of the selected MRSA were also detected using polymerase chain reaction. Of 32 MRSA isolates, 34.37%, 59.37%, and 81.25% showed positive results using CRA, TM or MtP, respectively. Biofilm production was found to be reduced in the presence of ethanol or ethylenediaminetetraacetic acid and at extreme pH values. On the other hand, glucose or heparin leads to a concentration dependent increase of biofilm production by the isolates. The selected biofilm producing MRSA isolate was found to harbor the icaA, icaD and up to nine of 10 tested MSCRAMM genes, whereas the selected non biofilm producing MRSA isolate did not carry any of the tested genes. The MtP method was found to be the most effective phenotypic screening method for detection of biofilm formation by MRSA. Furthermore, the molecular approach should be taken into consideration for the rapid and correct diagnosis of virulent bacteria associated with contact eye lenses.

  20. Optimization of a lensless digital holographic otoscope system for transient measurements of the human tympanic membrane

    PubMed Central

    Dobrev, I.; Furlong, C.; Cheng, J. T.; Rosowski, J. J.

    2014-01-01

    In this paper, we propose a multi-pulsed double exposure (MPDE) acquisition method to quantify in full-field-of-view the transient (i.e., >10 kHz) acoustically induced nanometer scale displacements of the human tympanic membrane (TM or eardrum). The method takes advantage of the geometrical linearity and repeatability of the TM displacements to enable high-speed measurements with a conventional camera (i.e., <20 fps). The MPDE is implemented on a previously developed digital holographic system (DHS) to enhance its measurement capabilities, at a minimum cost, while avoiding constraints imposed by the spatial resolutions and dimensions of high-speed (i.e., >50 kfps) cameras. To our knowledge, there is currently no existing system to provide such capabilities for the study of the human TM. The combination of high temporal (i.e., >50 kHz) and spatial (i.e., >500k data points) resolutions enables measurements of the temporal and frequency response of all points across the surface of the TM simultaneously. The repeatability and accuracy of the MPDE method are verified against a Laser Doppler Vibrometer (LDV) on both artificial membranes and ex-vivo human TMs that are acoustically excited with a sharp (i.e., <100 μs duration) click. The measuring capabilities of the DHS, enhanced by the MPDE acquisition method, allow for quantification of spatially dependent motion parameters of the TM, such as modal frequencies, time constants, as well as inferring local material properties. PMID:25780271

  1. Regional forest cover estimation via remote sensing: the calibration center concept

    Treesearch

    Louis R. Iverson; Elizabeth A. Cook; Robin L. Graham; Robin L. Graham

    1994-01-01

    A method for combining Landsat Thematic Mapper (TM), Advanced Very High Resolution Radiometer (AVHRR) imagery, and other biogeographic data to estimate forest cover over large regions is applied and evaluated at two locations. In this method, TM data are used to classify a small area (calibration center) into forest/nonforest; the resulting forest cover map is then...

  2. Melting of Cu nanoclusters by molecular dynamics simulation

    NASA Astrophysics Data System (ADS)

    Wang, Li; Zhang, Yanning; Bian, Xiufang; Chen, Ying

    2003-04-01

    We present a detailed molecular dynamics study of the melting of copper nanoclusters with up to 8628 atoms within the framework of the embedded-atom method. The finding indicates that there exists an intermediate nanocrystal regime above 456 atoms. The linear relation between the cluster size and its thermodynamics properties is obeyed in this regime. Melting first occurs at the surface of the clusters, leading to Tm, N= Tm,Bulk- αN-1/3, dropping from Tm,Bulk=1360 K to Tm,456=990 K. In addition, the size, surface energy as well as the root mean square displacement (RMSD) of the clusters in the intermediate regime have been investigated.

  3. Indirect gonioscopy system for imaging iridocorneal angle of eye

    NASA Astrophysics Data System (ADS)

    Perinchery, Sandeep M.; Fu, Chan Yiu; Baskaran, Mani; Aung, Tin; Murukeshan, V. M.

    2017-08-01

    Current clinical optical imaging systems do not provide sufficient structural information of trabecular meshwork (TM) in the iridocorneal angle (ICA) of the eye due to their low resolution. Increase in the intraocular pressure (IOP) can occur due to the abnormalities in TM, which could subsequently lead to glaucoma. Here, we present an indirect gonioscopy based imaging probe with significantly improved visualization of structures in the ICA including TM region, compared to the currently available tools. Imaging quality of the developed system was tested in porcine samples. Improved direct high quality visualization of the TM region through this system can be used for Laser trabeculoplasty, which is a primary treatment of glaucoma. This system is expected to be used complementary to angle photography and gonioscopy.

  4. An imaged-based inverse finite element method to determine in-vivo mechanical properties of the human trabecular meshwork.

    PubMed

    Pant, Anup D; Kagemann, Larry; Schuman, Joel S; Sigal, Ian A; Amini, Rouzbeh

    2017-01-01

    Previous studies have shown that the trabecular meshwork (TM) is mechanically stiffer in glaucomatous eyes as compared to normal eyes. It is believed that elevated TM stiffness increases resistance to the aqueous humor outflow, producing increased intraocular pressure (IOP). It would be advantageous to measure TM mechanical properties in vivo , as these properties are believed to play an important role in the pathophysiology of glaucoma and could be useful for identifying potential risk factors. The purpose of this study was to develop a method to estimate in-vivo TM mechanical properties using clinically available exams and computer simulations. Inverse finite element simulation. A finite element model of the TM was constructed from optical coherence tomography (OCT) images of a healthy volunteer before and during IOP elevation. An axisymmetric model of the TM was then constructed. Images of the TM at a baseline IOP level of 11, and elevated level of 23 mmHg were treated as the undeformed and deformed configurations, respectively. An inverse modeling technique was subsequently used to estimate the TM shear modulus ( G ). An optimization technique was used to find the shear modulus that minimized the difference between Schlemm's canal area in the in-vivo images and simulations. Upon completion of inverse finite element modeling, the simulated area of the Schlemm's canal changed from 8,889 µm 2 to 2,088 µm 2 , similar to the experimentally measured areal change of the canal (from 8,889 µm 2 to 2,100 µm 2 ). The calculated value of shear modulus was found to be 1.93 kPa, (implying an approximate Young's modulus of 5.75 kPa), which is consistent with previous ex-vivo measurements. The combined imaging and computational simulation technique provides a unique approach to calculate the mechanical properties of the TM in vivo without any surgical intervention. Quantification of such mechanical properties will help us examine the mechanistic role of TM biomechanics in the regulation of IOP in healthy and glaucomatous eyes.

  5. Comparison of energy expenditure on a treadmill vs. an elliptical device at a self-selected exercise intensity.

    PubMed

    Brown, Gregory A; Cook, Chad M; Krueger, Ryan D; Heelan, Kate A

    2010-06-01

    Treadmills (TM) and elliptical devices (EL) are popular forms of exercise equipment. The differences in the training stimulus presented by TM or EL are unknown. The purpose of this investigation was to evaluate oxygen consumption, energy expenditure, and heart rate on a TM or EL when persons exercise at the same perceived level of exertion. After measuring peak oxygen uptake (VO2peak) in 9 male and 9 female untrained college-aged participants, the subjects performed 2 separate 15-minute submaximal exercise tests on the TM and EL at a rating of perceived exertion (RPE) of 12-13. VO2peak was higher (p<0.05) in the males (48.6+/-1.5 vs. 45.2+/-1.6 ml/kg/min) than the females (41.7+/-1.8 vs. 38.8+/-2.2 ml/kg/min) for both TM and EL (means+/-standard error of the mean; for TM vs. EL respectively), but there were no differences in the measured VO2peak between TM or EL. During submaximal exercise there were no differences in RPE between TM and EL. Total oxygen consumption was higher (p<0.05) in males (30.8+/-2.2 vs. 34.9+/-2.2 L) than females (24.1+/-1.8 vs. 26.9+/-1.7 L) but did not differ between TM and EL. Energy expenditure was not different between TM (569+/-110 J) or EL (636+/-120 kJ). Heart rate was higher (p<0.05) on the EL (164+/-16 beats/min) compared to the TM (145+/-15 beats/min). When subjects exercise at the same RPE on TM or EL, oxygen consumption and energy expenditure are similar in spite of a higher heart rate on the EL. These data indicate that during cross training or noncompetition-specific exercise, an elliptical device is an acceptable alternative to a treadmill.

  6. Does Content Knowledge Affect TOEFL iBT[TM] Reading Performance? A Confirmatory Approach to Differential Item Functioning. TOEFL iBT Research Report. RR-09-29

    ERIC Educational Resources Information Center

    Liu, Ou Lydia; Schedl, Mary; Malloy, Jeanne; Kong, Nan

    2009-01-01

    The TOEFL iBT[TM] has increased the length of the reading passages in the reading section compared to the passages on the TOEFL[R] computer-based test (CBT) to better approximate academic reading in North American universities, resulting in a reduced number of passages in the reading test. A concern arising from this change is whether the decrease…

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Herbel, J.L.; Hunt, C.D.

    An experiment was designed to test the hypothesis that dietary boron impacts upon the function of various coenzymes involved in energy metabolism. In a 2 {times} 7 factorially-arranged experiment, weanling, vitamin D{sub 3}-deprived rats were fed a ground corn-casein-corn oil based diet supplemented with 0 or 2 mg boron/kg and 50% of the requirement for thiamine (TM), riboflavin (RF), pantothenic acid (PA) or pyridoxine (PX); 0% for folic acid (FA) or nicotinic acid (NA). All vitamins were supplemented in adequate amounts in the control diet. At 8 weeks of age, the TM dietary treatment was the one most affected bymore » supplemental dietary boron (SDB). In rats that were fed 50% TM, SDB increased plasma concentrations of triglyceride (TG) and activity of alanine transaminase (ALT), and the liver to body weight (L/B) ratio. However, in the SDB animals, adequate amounts of TM decreased the means of those variables to near that observed in non-SDB rats fed 50% TM. The findings suggest that an interaction between dietary boron and TM affects lipid metabolism.« less

  8. Buffer Optimization of Thermal Melt Assays of Plasmodium Proteins for Detection of Small-Molecule Ligands

    PubMed Central

    Crowther, Gregory J.; Napuli, Alberto J.; Thomas, Andrew P.; Chung, Diana J.; Kovzun, Kuzma V.; Leibly, David J.; Castaneda, Lisa J.; Bhandari, Janhavi; Damman, Christopher J.; Hui, Raymond; Hol, Wim G. J.; Buckner, Frederick S.; Verlinde, Christophe L. M. J.; Zhang, Zhongsheng; Fan, Erkang; Van Voorhis, Wesley C.

    2010-01-01

    In the last decade, thermal melt/thermal shift assays have become a common tool for identifying ligands and other factors that stabilize specific proteins. Increased stability is indicated by an increase in the protein's melting temperature (Tm). In optimizing the assays for subsequent screening of compound libraries, it is important to minimize the variability of Tm measurements so as to maximize the assay's ability to detect potential ligands. Here we present an investigation of Tm variability in recombinant proteins from Plasmodium parasites. Ligands of Plasmodium proteins are particularly interesting as potential starting points for drugs for malaria, and new drugs are urgently needed. A single standard buffer (100 mM HEPES, pH 7.5, 150 mM NaCl) permitted estimation of Tm for 58 of 61 Plasmodium proteins tested. However, with several proteins, Tm could not be measured with a consistency suitable for high-throughput screening unless alternative protein-specific buffers were employed. We conclude that buffer optimization to minimize variability in Tm measurements increases the success of thermal melt screens involving proteins for which a standard buffer is suboptimal. PMID:19470714

  9. Ligand binding to the human MT2 melatonin receptor: The role of residues in transmembrane domains 3, 6, and 7

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mazna, Petr; Berka, Karel; Jelinkova, Irena

    To better understand the mechanism of interactions between G-protein-coupled melatonin receptors and their ligands, our previously reported homology model of human MT2 receptor with docked 2-iodomelatonin was further refined and used to select residues within TM3, TM6, and TM7 potentially important for receptor-ligand interactions. Selected residues were mutated and radioligand-binding assay was used to test the binding affinities of hMT2 receptors transiently expressed in HEK293 cells. Our data demonstrate that residues N268 and A275 in TM6 as well as residues V291 and L295 in TM7 are essential for 2-iodomelatonin binding to the hMT2 receptor, while TM3 residues M120, G121, V124,more » and I125 may participate in binding of other receptor agonists and/or antagonists. Presented data also hint at possible specific interaction between the side-chain of Y188 in second extracellular loop and N-acetyl group of 2-iodomelatonin.« less

  10. Retrieval of land cover information under thin fog in Landsat TM image

    NASA Astrophysics Data System (ADS)

    Wei, Yuchun

    2008-04-01

    Thin fog, which often appears in remote sensing image of subtropical climate region, has resulted in the low image quantity and bad image mapping. Therefore, it is necessary to develop the image processing method to retrieve land cover information under thin fog. In this paper, the Landsat TM image near the Taihu Lake that is in the subtropical climate zone of China was used as an example, and the workflow and method used to retrieve the land cover information under thin fog have been built based on ENVI software and a single TM image. The basic step covers three parts: 1) isolating the thin fog area in image according to the spectral difference of different bands; 2) retrieving the visible band information of different land cover types under thin fog from the near-infrared bands according to the relationships between near-infrared bands and visible bands of different land cover types in the area without fog; 3) image post-process. The result showed that the method in the paper is easy and suitable, and can be used to improve the quantity of TM image mapping more effectively.

  11. Using dynamic programming to improve fiducial marker localization

    NASA Astrophysics Data System (ADS)

    Wan, Hanlin; Ge, Jiajia; Parikh, Parag

    2014-04-01

    Fiducial markers are used in a wide range of medical imaging applications. In radiation therapy, they are often implanted near tumors and used as motion surrogates that are tracked with fluoroscopy. We propose a novel and robust method based on dynamic programming (DP) for retrospectively localizing radiopaque fiducial markers in fluoroscopic images. Our method was compared to template matching (TM) algorithms on 407 data sets from 24 patients. We found that the performance of TM varied dramatically depending on the template used (ranging from 47% to 92% of data sets with a mean error <1 mm). DP by itself requires no template and performed as well as the best TM method, localizing the markers in 91% of the data sets with a mean error <1 mm. Finally, by combining DP and TM, we were able to localize the markers in 99% of the data sets with a mean error <1 mm, regardless of the template used. Our results show that DP can be a powerful tool for analyzing tumor motion, capable of accurately locating fiducial markers in fluoroscopic images regardless of marker type, shape, and size.

  12. A study: Effect of Students Peer Assisted Learning on Magnetic Field Achievement

    NASA Astrophysics Data System (ADS)

    Mueanploy, Wannapa

    2016-04-01

    This study is the case study of Physic II Course for students of Pathumwan Institute of Technology. The purpose of this study is: 1) to develop cooperative learning method of peer assisted learning (PAL), 2) to compare the learning achievement before and after studied magnetic field lesson by cooperative learning method of peer assisted learning. The population was engineering students of Pathumwan Institute of Technology (PIT’s students) who registered Physic II Course during year 2014. The sample used in this study was selected from the 72 students who passed in Physic I Course. The control groups learning magnetic fields by Traditional Method (TM) and experimental groups learning magnetic field by method of peers assisted learning. The students do pretest before the lesson and do post-test after the lesson by 20 items achievement tests of magnetic field. The post-test higher than pretest achievement significantly at 0.01 level.

  13. A True Eddy Accumulation - Eddy Covariance hybrid for measurements of turbulent trace gas fluxes

    NASA Astrophysics Data System (ADS)

    Siebicke, Lukas

    2016-04-01

    Eddy covariance (EC) is state-of-the-art in directly and continuously measuring turbulent fluxes of carbon dioxide and water vapor. However, low signal-to-noise ratios, high flow rates and missing or complex gas analyzers limit it's application to few scalars. True eddy accumulation, based on conditional sampling ideas by Desjardins in 1972, requires no fast response analyzers and is therefore potentially applicable to a wider range of scalars. Recently we showed possibly the first successful implementation of True Eddy Accumulation (TEA) measuring net ecosystem exchange of carbon dioxide of a grassland. However, most accumulation systems share the complexity of having to store discrete air samples in physical containers representing entire flux averaging intervals. The current study investigates merging principles of eddy accumulation and eddy covariance, which we here refer to as "true eddy accumulation in transient mode" (TEA-TM). This direct flux method TEA-TM combines true eddy accumulation with continuous sampling. The TEA-TM setup is simpler than discrete accumulation methods while avoiding the need for fast response gas analyzers and high flow rates required for EC. We implemented the proposed TEA-TM method and measured fluxes of carbon dioxide (CO2), methane (CH4) and water vapor (H2O) above a mixed beech forest at the Hainich Fluxnet and ICOS site, Germany, using a G2301 laser spectrometer (Picarro Inc., USA). We further simulated a TEA-TM sampling system using measured high frequency CO2 time series from an open-path gas analyzer. We operated TEA-TM side-by-side with open-, enclosed- and closed-path EC flux systems for CO2, H2O and CH4 (LI-7500, LI-7200, LI-6262, LI-7700, Licor, USA, and FGGA LGR, USA). First results show that TEA-TM CO2 fluxes were similar to EC fluxes. Remaining differences were similar to those between the three eddy covariance setups (open-, enclosed- and closed-path gas analyzers). Measured TEA-TM CO2 fluxes from our physical sampling system closely reproduced dynamics of simulated TEA-TM fluxes. In conclusion this study introduces a new approach to trace gas flux measurements using transient-mode true eddy accumulation. First TEA-TM CO2 fluxes compared favorably with side-by-side EC fluxes, in agreement with our previous experiments comparing discrete TEA to EC. True eddy accumulation has thus potential for measuring turbulent fluxes of a range of atmospheric tracers using slow response analyzers.

  14. Analysis methods for Thematic Mapper data of urban regions

    NASA Technical Reports Server (NTRS)

    Wang, S. C.

    1984-01-01

    Studies have indicated the difficulty in deriving a detailed land-use/land-cover classification for heterogeneous metropolitan areas with Landsat MSS and TM data. The major methodological issues of digital analysis which possibly have effected the results of classification are examined. In response to these methodological issues, a multichannel hierarchical clustering algorithm has been developed and tested for a more complete analysis of the data for urban areas.

  15. A Double-Blind, Placebo-Controlled Trial of Dexmethylphenidate Hydrochloride and D,l-Threo-Methylphenidate Hydrochloride in Children with Attention-Deficit-Hyperactivity Disorder

    ERIC Educational Resources Information Center

    Wigal, Sharon; Swanson, James M.; Feifel, David; Sangal, R. Bart; Elia, Josephine; Casat, Charles D.; Zeldis, Jerome B.; Conners, C. Keith

    2004-01-01

    Objective: To evaluate the efficacy and safety of dexmethylphenidate hydrochloride (d-MPH, Focalin[TM]) for the treatment of attention-deficit/hyperactivity disorder (ADHD) and to test an a priori hypothesis that d-MPH would have a longer duration of action than d,l-threo-methylphenidate (d,l-MPH). Method: This was a randomized, double-blind study…

  16. The effects of cloud inhomogeneities upon radiative fluxes, and the supply of a cloud truth validation dataset

    NASA Technical Reports Server (NTRS)

    Welch, Ronald M.

    1996-01-01

    The ASTER polar cloud mask algorithm is currently under development. Several classification techniques have been developed and implemented. The merits and accuracy of each are being examined. The classification techniques under investigation include fuzzy logic, hierarchical neural network, and a pairwise histogram comparison scheme based on sample histograms called the Paired Histogram Method. Scene adaptive methods also are being investigated as a means to improve classifier performance. The feature, arctan of Band 4 and Band 5, and the Band 2 vs. Band 4 feature space are key to separating frozen water (e.g., ice/snow, slush/wet ice, etc.) from cloud over frozen water, and land from cloud over land, respectively. A total of 82 Landsat TM circumpolar scenes are being used as a basis for algorithm development and testing. Numerous spectral features are being tested and include the 7 basic Landsat TM bands, in addition to ratios, differences, arctans, and normalized differences of each combination of bands. A technique for deriving cloud base and top height is developed. It uses 2-D cross correlation between a cloud edge and its corresponding shadow to determine the displacement of the cloud from its shadow. The height is then determined from this displacement, the solar zenith angle, and the sensor viewing angle.

  17. Enhancement of the blood compatibility of dialyzer membranes by the physical adsorption of human thrombomodulin (ART-123).

    PubMed

    Omichi, Masaaki; Matsusaki, Michiya; Kato, Shinya; Maruyama, Ikuro; Akashi, Mitsuru

    2010-11-01

    ART-123 is a recombinant soluble human thrombomodulin (hTM) with excellent anticoagulant activity. We focused on improving the blood compatibility of the polysulfone-polyvinylpyrrolidone dialyzer surface by the physical adsorption of ART-123 onto the surface. The blood compatibility of the dialyzer with the hTM adsorbed membrane was evaluated by measuring the differential pressure between the arterial and the venous pressures and by blood parameters during blood circulation. The hTM adsorbed dialyzer membrane inhibited blood clot formation without heparin administration due to the anticoagulant activity of hTM for over 4 h. The physically adsorbed hTM was stable during blood circulation, and it did not affect activated clotting time, which is significant drawback of heparin administration, and blood cell counts of RBC, WBC, or platelets. The physical adsorption of hTM onto the dialyzer membrane will be a simple and safe method to prevent blood coagulation during dialysis instead of heparin administration. © 2010 Wiley Periodicals, Inc.

  18. Comparison of three different methods to merge multiresolution and multispectral data: Landsat TM and SPOT panchromatic

    USGS Publications Warehouse

    Chavez, P.S.; Sides, S.C.; Anderson, J.A.

    1991-01-01

    The merging of multisensor image data is becoming a widely used procedure because of the complementary nature of various data sets. Ideally, the method used to merge data sets with high-spatial and high-spectral resolution should not distort the spectral characteristics of the high-spectral resolution data. This paper compares the results of three different methods used to merge the information contents of the Landsat Thematic Mapper (TM) and Satellite Pour l'Observation de la Terre (SPOT) panchromatic data. The comparison is based on spectral characteristics and is made using statistical, visual, and graphical analyses of the results. The three methods used to merge the information contents of the Landsat TM and SPOT panchromatic data were the Hue-Intensity-Saturation (HIS), Principal Component Analysis (PCA), and High-Pass Filter (HPF) procedures. The HIS method distorted the spectral characteristics of the data the most. The HPF method distorted the spectral characteristics the least; the distortions were minimal and difficult to detect. -Authors

  19. Energy transfer and visible-infrared quantum cutting photoluminescence modification in Tm-Yb codoped YPO(4) inverse opal photonic crystals.

    PubMed

    Wang, Siqin; Qiu, Jianbei; Wang, Qi; Zhou, Dacheng; Yang, Zhengwen

    2015-08-01

    YPO4:  Tm, Yb inverse opal photonic crystals were successfully synthesized by the colloidal crystal templates method, and the visible-infrared quantum cutting (QC) photoluminescence properties of YPO4:  Tm, Yb inverse opal photonic crystals were investigated. We obtained tetragonal phase YPO4 in all the samples when the samples sintered at 950°C for 5 h. The visible emission intensity of Tm3+ decreased significantly when the photonic bandgap was located at 650 nm under 480 nm excitation. On the contrary, the QC emission intensity of Yb3+ was enhanced as compared with the no photonic bandgap sample. When the photonic bandgap was located at 480 nm, the Yb3+ and Tm3+ light-emitting intensity weakened at the same time. We demonstrated that the energy transfer between Tm3+ and Yb3+ is enhanced by the suppression of the red emission of Tm3+. Additionally, the mechanisms for the influence of the photonic bandgap on the energy transfer process of the Tm3+, Yb3+ codoped YPO4 inverse opal are discussed.

  20. Computational study of the heterodimerization between μ and δ receptors

    NASA Astrophysics Data System (ADS)

    Liu, Xin; Kai, Ming; Jin, Lian; Wang, Rui

    2009-06-01

    A growing body of evidence indicated that the G protein coupled receptors exist as homo- or hetero-dimers in the living cell. The heterodimerization between μ and δ opioid receptors has attracted researchers' particular interests, it is reported to display novel pharmacological and signalling regulation properties. In this study, we construct the full-length 3D-model of μ and δ opioid receptors using the homology modelling method. Threading program was used to predict the possible templates for the N- and C-terminus domains. Then, a 30 ns molecular dynamics simulations was performed with each receptor embedded in an explicit membrane-water environment to refine and explore the conformational space. Based on the structures extracted from the molecular dynamics, the likely interface of μ-δ heterodimer was investigated through the analysis of protein-protein docking, cluster, shape complementary and interaction energy. The computational modelling works revealed that the most likely interface of heterodimer was formed between the transmembrane1,7 (TM1,7) domains of μ receptor and the TM(4,5) domains of δ receptor, with emphasis on μ-TM1 and δ-TM4, the next likely interface was μ(TM6,7)-δ(TM4,5), with emphasis on μ-TM6 and δ-TM4. Our results were consistent with previous reports.

  1. Real-time automated thickness measurement of the in vivo human tympanic membrane using optical coherence tomography

    PubMed Central

    Hubler, Zita; Shemonski, Nathan D.; Shelton, Ryan L.; Monroy, Guillermo L.; Nolan, Ryan M.

    2015-01-01

    Background Otitis media (OM), an infection in the middle ear, is extremely common in the pediatric population. Current gold-standard methods for diagnosis include otoscopy for visualizing the surface features of the tympanic membrane (TM) and making qualitative assessments to determine middle ear content. OM typically presents as an acute infection, but can progress to chronic OM, and after numerous infections and antibiotic treatments over the course of many months, this disease is often treated by surgically inserting small tubes in the TM to relieve pressure, enable drainage, and provide aeration to the middle ear. Diagnosis and monitoring of OM is critical for successful management, but remains largely qualitative. Methods We have developed an optical coherence tomography (OCT) system for high-resolution, depth-resolved, cross-sectional imaging of the TM and middle ear content, and for the quantitative assessment of in vivo TM thickness including the presence or absence of a middle ear biofilm. A novel algorithm was developed and demonstrated for automatic, real-time, and accurate measurement of TM thickness to aid in the diagnosis and monitoring of OM and other middle ear conditions. The segmentation algorithm applies a Hough transform to the OCT image data to determine the boundaries of the TM to calculate thickness. Results The use of OCT and this segmentation algorithm is demonstrated first on layered phantoms and then during real-time acquisition of in vivo OCT from humans. For the layered phantoms, measured thicknesses varied by approximately 5 µm over time in the presence of large axial and rotational motion. In vivo data also demonstrated differences in thicknesses both spatially on a single TM, and across normal, acute, and chronic OM cases. Conclusions Real-time segmentation and thickness measurements of image data from both healthy subjects and those with acute and chronic OM demonstrate the use of OCT and this algorithm as a robust, quantitative, and accurate method for use during real-time in vivo human imaging. PMID:25694956

  2. Randomized controlled trial of web-based multimodal therapy for children with acquired brain injury to improve gross motor capacity and performance.

    PubMed

    Baque, Emmah; Barber, Lee; Sakzewski, Leanne; Boyd, Roslyn N

    2017-06-01

    To compare efficacy of a web-based multimodal training programme, 'Move it to improve it' (Mitii TM ), to usual care on gross motor capacity and performance for children with an acquired brain injury. Randomized waitlist controlled trial. Home environment. A total of 60 independently ambulant children (30 in each group), minimum 12 months post-acquired brain injury were recruited and randomly allocated to receive either 20 weeks of Mitii TM training (30 minutes/day, six days/week, total 60 hours) immediately, or waitlisted (usual care control group) for 20 weeks. A total of 58 children completed baseline assessments (32 males; age 11 years 11 months ± 2 years 6 months; Gross Motor Function Classification System equivalent I = 29, II = 29). The Mitii TM program comprised of gross motor, upper limb and visual perception/cognitive activities. The primary outcome was 30-second, repetition maximum functional strength tests for the lower limb (sit-to-stand, step-ups, half-kneel to stand). Secondary outcomes were the 6-minute walk test, High-level Mobility Assessment Tool, Timed Up and Go Test and habitual physical activity as captured by four-day accelerometry. Groups were equivalent at baseline on demographic and clinical measures. The Mitii TM group demonstrated significantly greater improvements on combined score of functional strength tests (mean difference 10.19 repetitions; 95% confidence interval, 3.26-17.11; p = 0.006) compared with the control group. There were no other between-group differences on secondary outcomes. Although the Mitii TM programme demonstrated statistically significant improvements in the functional strength tests of the lower limb, results did not exceed the minimum detectable change and cannot be considered clinically relevant for children with an acquired brain injury. Australian New Zealand Clinical Trials Registration Number, ANZCTR12613000403730.

  3. Small Unmanned Aircraft Electromagnetic Interference (EMI) Initial Assessment

    NASA Technical Reports Server (NTRS)

    Jung, Jaewoo; Ippolito, Corey; Rogers, Christopher; Kerczewski, Robert; Downey, Alan; Matheou, Konstantin

    2018-01-01

    With many applications envisioned for small Unmanned Aircraft Systems (sUAS), and potentially millions of sUAS expected to be in operation in the future, the electromagnetic interference environment associated with the sUAS is of interest to understanding the potential performance impacts on the sUAS command and control communications link as well as the sUAS payload and payload links. As part of NASAâ€"TM"s UAS Traffic Management (UTM) Project, flight experiments are planned to characterize the RF environment at altitudes up to 400 ft to better understand how UTM command and control links can be expected to perform. The flight experiments will use an RF channel sensing payload attached to an sUAS. In terms of the payload being capable of measuring relatively low level signals at altitude, electromagnetic interference (EMI) emanating from the sUAS vehicle itself could potentially complicate the measurement process. For this reason, NASA was interested in measuring the EMI performance of the sUAS planned for these flight experiments, a DJI model S1000. The S1000 was thus measured in a controlled EMI test chamber at the NASA Ames Research Center. The S1000 is a carbon fiber based platform with eight rotors. As such, the EMI test results represent potential performance of a number of similar sUAS types. sUAS platforms significantly different from the S1000 may also require EMI testing, and the method employed for NASAâ€"TM"s S1000 EMI tests can be applied to other platforms. In this paper we describe the UTM project, the RF channel sensing payload, the EMI testing method and EMI test results for the S1000, and discuss the implications of these results.

  4. An Evaluation of the IntelliMetric[SM] Essay Scoring System

    ERIC Educational Resources Information Center

    Rudner, Lawrence M.; Garcia, Veronica; Welch, Catherine

    2006-01-01

    This report provides a two-part evaluation of the IntelliMetric[SM] automated essay scoring system based on its performance scoring essays from the Analytic Writing Assessment of the Graduate Management Admission Test[TM] (GMAT[TM]). The IntelliMetric system performance is first compared to that of individual human raters, a Bayesian system…

  5. Automated Essay Scoring versus Human Scoring: A Comparative Study

    ERIC Educational Resources Information Center

    Wang, Jinhao; Brown, Michelle Stallone

    2007-01-01

    The current research was conducted to investigate the validity of automated essay scoring (AES) by comparing group mean scores assigned by an AES tool, IntelliMetric [TM] and human raters. Data collection included administering the Texas version of the WriterPlacer "Plus" test and obtaining scores assigned by IntelliMetric [TM] and by…

  6. Study on the Immunoreactivity of Triticum monococcum (Einkorn) Wheat in Patients with Wheat-Dependent Exercise-Induced Anaphylaxis for the Production of Hypoallergenic Foods.

    PubMed

    Lombardo, Carla; Bolla, Michela; Chignola, Roberto; Senna, Gianenrico; Rossin, Giacomo; Caruso, Beatrice; Tomelleri, Carlo; Cecconi, Daniela; Brandolini, Andrea; Zoccatelli, Gianni

    2015-09-23

    Wheat [Triticum aestivum (T.a.)] ingestion can cause a specific allergic reaction, which is called wheat-dependent exercise-induced anaphylaxis (WDEIA). The major allergen involved is ω-5 gliadin, a gluten protein coded by genes located on the B genome. Our aim was to study the immunoreactivity of proteins in Triticum monococcum (einkorn, T.m.), a diploid ancestral wheat lacking B chromosomes, for possible use in the production of hypoallergenic foods. A total of 14 patients with a clear history of WDEIA and specific immunoglobulin E (IgE) to ω-5 gliadin were enrolled. Skin prick test (SPT) with a commercial wheat extract and an in-house T.a. gluten diagnostic solution tested positive for 43 and 100% of the cases, respectively. No reactivity in patients tested with solutions prepared from four T.m. accessions was observed. The immunoblotting of T.m. gluten proteins performed with the sera of patients showed different IgE-binding profiles with respect to T.a., confirming the absence of ω-5 gliadin. A general lower immunoreactivity of T.m. gluten proteins with scarce cross-reactivity to ω-5 gliadin epitopes was assessed by an enzyme-linked immunosorbent assay (ELISA). Given the absence of reactivity by SPT and the limited cross-reactivity with ω-5 gliadin, T.m. might represent a potential candidate in the production of hypoallergenic bakery products for patients sensitized to ω-5 gliadin. Further analyses need to be carried out regarding its safety.

  7. Iron-related disturbances of cell-mediated immunity in multitransfused children with thalassemia major.

    PubMed Central

    Pardalos, G; Kanakoudi-Tsakalidis, F; Malaka-Zafiriu, M; Tsantali, H; Athanasiou-Metaxa, M; Kallinikos, G; Papaevangelou, G

    1987-01-01

    Immunological abnormalities have been observed in many haemophiliacs receiving clotting factor concentrates. To determine whether similar changes also occur after repeated blood transfusions we estimated T cell subsets and cutaneous delayed hypersensitivity (CDH) in 50 multitransfused children with beta-thalassemia major (beta-TM). All patients were also tested for anti-HTLV-III/LAV antibodies. A diminished percentage of T lymphocytes (E-rosettes, T3+), and T4+ cells and a low T4/T8 ratio was found in patients as compared to age and sex matched controls (P less than 0.001). Negative CDH tests to specific antigens (Multi-test) were also found in a significantly larger proportion of beta-TM children (P less than 0.01). Antibodies against HTLV-III/LAV were negative in all patients. Decreased T4/T8 ratio in beta-TM children was primarily due to a reduction of T4+ cells and was inversely correlated to the patients' age, number of units of transfused blood (P less than 0.05) and especially to ferritin serum levels and annual iron balance (P less than 0.001). These findings indicate that immunological abnormalities in beta-TM patients appear to be acquired, transfusion-associated and related to iron load which depends on the appropriate chelation therapy. PMID:3498564

  8. Effects of Trypsinization and Mineralization on Intrasynovial Tendon Allograft Healing to Bone

    PubMed Central

    Qu, Jin; van Alphen, Nick A.; Thoreson, Andrew R.; Chen, Qingshan; An, Kai-Nan; Amadio, Peter C.; Schmid, Thomas M.; Zhao, Chunfeng

    2014-01-01

    The purpose of the current study was to develop a novel technology to enhance tendon-to-bone interface healing by trypsinizing and mineralizing (TM) an intrasynovial tendon allograft in a rabbit bone tunnel model. Eight rabbit flexor digitorum profundus (FDP) tendons were used to optimize the trypsinization process. An additional 24 FDP tendons were stratified into control and TM groups; in each group, 4 tendons were used for in vitro evaluation of TM and 8 were transplanted into proximal tibial bone tunnels in rabbits. The samples were evaluated histologically and with mechanical testing at postoperative week 8. Maximum failure strength and linear stiffness were not significantly different between the control and TM tendons. A thin fibrous band of scar tissue formed at the graft-to-bone interface in the control group. However, only the TM group showed obvious new bone formation inside the tendon graft and a visible fibrocartilage layer at the bone tunnel entrance. This study is the first to explore effects of TM on the intrasynovial allograft healing to a bone tunnel. TM showed beneficial effects on chondrogenesis, osteogenesis, and integration of the intrasynovial tendon graft, but mechanical strength was the same as the control tendons in this short-term in vivo study. PMID:25611186

  9. Determination of total carbonates in soil archaeometry using a new pressure method with temperature compensation

    NASA Astrophysics Data System (ADS)

    Barouchas, Pantelis; Koulos, Vasilios; Melfos, Vasilios

    2017-04-01

    For the determination of total carbonates in soil archaeometry a new technique was applied using a multi-sensor philosophy, which combines simultaneous measurement of pressure and temperature. This technology is innovative and complies with EN ISO 10693:2013, ASTM D4373-02(2007) and Soil Science Society of America standard test methods for calcium carbonate content in soils and sediments. The total carbonates analysis is based on a pressure method that utilizes the FOGII Digital Soil CalcimeterTM, which is a portable apparatus. The total carbonate content determined by treating a 1.000 g (+/- 0.001 g) dried sample specimens with 6N hydrochloric acid (HCL) reagent grade, in an enclosed reaction vessel. Carbon dioxide gas evolved during the reaction between the acid and carbonate fraction of the specimen, was measured by the resulting pressure generated, taking in account the temperature conditions during the reaction. Prior to analysis the procedure was validated with Sand/Soil mixtures from BIPEA proficiency testing program with soils of different origins. For applying this new method in archaeometry a total number of ten samples were used from various rocks which are related with cultural constructions and implements in Greece. They represent a large range of periods since the Neolithic times, and were selected because there was an uncertainty about their accurate mineralogical composition especially regarding the presence of carbonate minerals. The results were compared to the results from ELTRA CS580 inorganic carbon analyzer using an infrared cell. The determination of total carbonates for 10 samples from different ancient sites indicated a very good correlation (R2 >0.97) between the pressure method with temperature compensation and the infrared method. The proposed method is quickly and accurate in archaeometry and can replace easily other techniques for total carbonates testing. The FOGII Digital Soil CalcimeterTM is portable and easily can be carried for field work in archaeology.

  10. Middle Ear Mechanics of Cartilage Tympanoplasty Evaluated by Laser Holography and Vibrometry

    PubMed Central

    Aarnisalo, Antti A.; Cheng, Jeffrey T.; Ravicz, Michael E.; Hulli, Nesim; Harrington, Ellery J.; Hernandez-Montes, Maria S.; Furlong, Cosme; Merchant, Saumil N.; Rosowski, John J.

    2010-01-01

    Goals To assess the effects of thickness and position of cartilage used to reconstruct the tympanic membrane (TM) using a novel technique, time-averaged laser holography. Background Cartilage is commonly used in TM reconstruction to prevent formation of retraction pockets. The thickness, position, and shape of the cartilage graft may adversely affect TM motion and hearing. We sought to systematically investigate these parameters in an experimental setting. Methods Computer-assisted optoelectronic laser holography was used in 4 human cadaveric temporal bones to study sound-induced TM motion for 500 Hz to 8 kHz. Stapes velocity was measured with a laser Doppler vibrometer. Baseline (control) measurements were made with the TM intact. Measurements were repeated after a 0.5- or 1.0-mm-thick oval piece of conchal cartilage was placed on the medial TM surface in the posterior-superior quadrant. The cartilage was rotated so that it was either in contact with the bony tympanic rim and manubrium or not. Results At frequencies less than 4 kHz, the cartilage graft had only minor effects on the overall TM fringe patterns. The different conditions had no effects on stapes velocity. Greater than 4 kHz, TM motion was reduced over the grafted TM, both with 0.5- and 1.0-mm-thick grafts. No significant differences in stapes velocity were seen with the 2 different thicknesses of cartilage compared with control. Conclusion Computer-assisted optoelectronic laser holography is a promising technique to investigate middle ear mechanics after tympanoplasty. Such positioning may prevent postoperative TM retraction. These findings and conclusions apply to cartilage placed in the posterior-superior TM quadrant. PMID:19779389

  11. Effects of glaucoma medications and preservatives on cultured human trabecular meshwork and non-pigmented ciliary epithelial cell lines.

    PubMed

    Ammar, David A; Kahook, Malik Y

    2011-10-01

    We investigated the potential cytotoxicity of various topical ophthalmic glaucoma formulations containing different preservatives in cultured human trabecular meshwork (TM) and non-pigmented ciliary epithelial (NPCE) cell lines. We tested 0.004% travoprost preserved with either 0.015% benzalkonium chloride (BAK), sofZia or 0.001% Polyquad (PQ); and 0.005% latanoprost preserved with 0.020% BAK. We also tested a range of BAK concentrations in balanced salt solution (BSS). TM cells were treated for 10 min at 37°C with solutions diluted 1:10 to mimic the reduced penetration of topical preparations to the anterior chamber. Viability was determined by the uptake of the fluorescent vital dye calcein-AM (n = 6). BAK solutions (diluted 1:10) demonstrated a dose-dependent reduction in cell viability in both cell types (TM and NPCE). With a 1:10 dilution of 0.020% BAK, there were significantly more living NPCE cells (89 ± 6%) than TM cells (57 ± 6%; p < 0.001). In TM cells, travoprost + BAK had statistically fewer live cells (83 ± 5%) than both travoprost + sofZia (97 ± 5%) and travoprost + PQ (97 ± 6%; p < 0.05). Compared with BSS-treated NPCE cells, travoprost had statistically fewer live cells (p < 0.05) when preserved with BAK (85 ± 16%), sofZia (91 ± 6%) or PQ (94 ± 2%). These results demonstrate that substitution of BAK from topical ophthalmic drugs results in greater viability of cultured TM cells, the cells involved in the conventional outflow pathway. Cultured NPCE, responsible for aqueous inflow, appear more resilient to BAK.

  12. Evaluation of the COBAS Hepatitis C Virus (HCV) TaqMan analyte-specific reagent assay and comparison to the COBAS Amplicor HCV Monitor V2.0 and Versant HCV bDNA 3.0 assays.

    PubMed

    Konnick, Eric Q; Williams, Sheri M; Ashwood, Edward R; Hillyard, David R

    2005-05-01

    Performance characteristics of the COBAS hepatitis C virus (HCV) TaqMan analyte-specific reagent (TM-ASR) assay using the QIAGEN BioRobot 9604 for RNA extraction were evaluated and compared to the COBAS Amplicor HCV Monitor V2.0 (Amplicor) and Versant HCV bDNA 3.0 (Versant) assays using clinical samples. Calibration of TM-ASR using Armored RNA allowed determination of the distribution of HCV RNA in clinical samples, using 22,399 clinical samples. Limit of detection, linearity, and inter- and intraassay assay precision were determined for the TM-ASR assay using multiple clinical specimen panels across multiple determinations. Genotype specificity for the TM-ASR assay was determined using samples with different HCV RNA genotypes evaluated and compared against predetermined results. Contamination control of the TM-ASR assay was evaluated using pools of HCV RNA-positive and -negative samples tested in a checkerboard pattern over 12 runs of 96 samples. Correlation of the TM-ASR, Amplicor, and Versant assays was determined using 100 paired clinical samples and Deming regression analysis. The TM-ASR performed well with respect to linearity, precision, and contamination control. The correlation between TM-ASR and the Amplicor and Versant assays was poor, with large differences between assay results for individual samples. Calibration of the TM-ASR assay with Armored RNA allowed for a wide dynamic range and description of the distribution of HCV RNA in clinical samples.

  13. Evaluation of the COBAS Hepatitis C Virus (HCV) TaqMan Analyte-Specific Reagent Assay and Comparison to the COBAS Amplicor HCV Monitor V2.0 and Versant HCV bDNA 3.0 Assays

    PubMed Central

    Konnick, Eric Q.; Williams, Sheri M.; Ashwood, Edward R.; Hillyard, David R.

    2005-01-01

    Performance characteristics of the COBAS hepatitis C virus (HCV) TaqMan analyte-specific reagent (TM-ASR) assay using the QIAGEN BioRobot 9604 for RNA extraction were evaluated and compared to the COBAS Amplicor HCV Monitor V2.0 (Amplicor) and Versant HCV bDNA 3.0 (Versant) assays using clinical samples. Calibration of TM-ASR using Armored RNA allowed determination of the distribution of HCV RNA in clinical samples, using 22,399 clinical samples. Limit of detection, linearity, and inter- and intraassay assay precision were determined for the TM-ASR assay using multiple clinical specimen panels across multiple determinations. Genotype specificity for the TM-ASR assay was determined using samples with different HCV RNA genotypes evaluated and compared against predetermined results. Contamination control of the TM-ASR assay was evaluated using pools of HCV RNA-positive and -negative samples tested in a checkerboard pattern over 12 runs of 96 samples. Correlation of the TM-ASR, Amplicor, and Versant assays was determined using 100 paired clinical samples and Deming regression analysis. The TM-ASR performed well with respect to linearity, precision, and contamination control. The correlation between TM-ASR and the Amplicor and Versant assays was poor, with large differences between assay results for individual samples. Calibration of the TM-ASR assay with Armored RNA allowed for a wide dynamic range and description of the distribution of HCV RNA in clinical samples. PMID:15872232

  14. Functional role of oligomerization for bacterial and plant SWEET sugar transporter family.

    PubMed

    Xuan, Yuan Hu; Hu, Yi Bing; Chen, Li-Qing; Sosso, Davide; Ducat, Daniel C; Hou, Bi-Huei; Frommer, Wolf B

    2013-09-24

    Eukaryotic sugar transporters of the MFS and SWEET superfamilies consist of 12 and 7 α-helical transmembrane domains (TMs), respectively. Structural analyses indicate that MFS transporters evolved from a series of tandem duplications of an ancestral 3-TM unit. SWEETs are heptahelical proteins carrying a tandem repeat of 3-TM separated by a single TM. Here, we show that prokaryotes have ancestral SWEET homologs with only 3-TM and that the Bradyrhizobium japonicum SemiSWEET1, like Arabidopsis SWEET11, mediates sucrose transport. Eukaryotic SWEETs most likely evolved by internal duplication of the 3-TM, suggesting that SemiSWEETs form oligomers to create a functional pore. However, it remains elusive whether the 7-TM SWEETs are the functional unit or require oligomerization to form a pore sufficiently large to allow for sucrose passage. Split ubiquitin yeast two-hybrid and split GFP assays indicate that Arabidopsis SWEETs homo- and heterooligomerize. We examined mutant SWEET variants for negative dominance to test if oligomerization is necessary for function. Mutation of the conserved Y57 or G58 in SWEET1 led to loss of activity. Coexpression of the defective mutants with functional A. thaliana SWEET1 inhibited glucose transport, indicating that homooligomerization is necessary for function. Collectively, these data imply that the basic unit of SWEETs, similar to MFS sugar transporters, is a 3-TM unit and that a functional transporter contains at least four such domains. We hypothesize that the functional unit of the SWEET family of transporters possesses a structure resembling the 12-TM MFS structure, however, with a parallel orientation of the 3-TM unit.

  15. Functional role of oligomerization for bacterial and plant SWEET sugar transporter family

    PubMed Central

    Xuan, Yuan Hu; Hu, Yi Bing; Chen, Li-Qing; Sosso, Davide; Ducat, Daniel C.; Hou, Bi-Huei; Frommer, Wolf B.

    2013-01-01

    Eukaryotic sugar transporters of the MFS and SWEET superfamilies consist of 12 and 7 α-helical transmembrane domains (TMs), respectively. Structural analyses indicate that MFS transporters evolved from a series of tandem duplications of an ancestral 3-TM unit. SWEETs are heptahelical proteins carrying a tandem repeat of 3-TM separated by a single TM. Here, we show that prokaryotes have ancestral SWEET homologs with only 3-TM and that the Bradyrhizobium japonicum SemiSWEET1, like Arabidopsis SWEET11, mediates sucrose transport. Eukaryotic SWEETs most likely evolved by internal duplication of the 3-TM, suggesting that SemiSWEETs form oligomers to create a functional pore. However, it remains elusive whether the 7-TM SWEETs are the functional unit or require oligomerization to form a pore sufficiently large to allow for sucrose passage. Split ubiquitin yeast two-hybrid and split GFP assays indicate that Arabidopsis SWEETs homo- and heterooligomerize. We examined mutant SWEET variants for negative dominance to test if oligomerization is necessary for function. Mutation of the conserved Y57 or G58 in SWEET1 led to loss of activity. Coexpression of the defective mutants with functional A. thaliana SWEET1 inhibited glucose transport, indicating that homooligomerization is necessary for function. Collectively, these data imply that the basic unit of SWEETs, similar to MFS sugar transporters, is a 3-TM unit and that a functional transporter contains at least four such domains. We hypothesize that the functional unit of the SWEET family of transporters possesses a structure resembling the 12-TM MFS structure, however, with a parallel orientation of the 3-TM unit. PMID:24027245

  16. LANDSAT-4 Science Characterization Early Results. Volume 3, Part 2: Thematic Mapper (TM)

    NASA Technical Reports Server (NTRS)

    Barker, J. L. (Editor)

    1985-01-01

    The calibration of the LANDSAT 4 thematic mapper is discussed as well as the atmospheric, radiometric, and geometric accuracy and correction of data obtained with this sensor. Methods are given for assessing TM band to band registration.

  17. The influence of the dispersion method on the electrical properties of vapor-grown carbon nanofiber/epoxy composites

    PubMed Central

    2011-01-01

    The influence of the dispersion of vapor-grown carbon nanofibers (VGCNF) on the electrical properties of VGCNF/Epoxy composites has been studied. A homogenous dispersion of the VGCNF does not imply better electrical properties. In fact, it is demonstrated that the most simple of the tested dispersion methods results in higher conductivity, since the presence of well-distributed nanofiber clusters appears to be a key factor for increasing composite conductivity. PACS: 72.80.Tm; 73.63.Fg; 81.05.Qk PMID:21711873

  18. 7TMRmine: a Web server for hierarchical mining of 7TMR proteins

    PubMed Central

    Lu, Guoqing; Wang, Zhifang; Jones, Alan M; Moriyama, Etsuko N

    2009-01-01

    Background Seven-transmembrane region-containing receptors (7TMRs) play central roles in eukaryotic signal transduction. Due to their biomedical importance, thorough mining of 7TMRs from diverse genomes has been an active target of bioinformatics and pharmacogenomics research. The need for new and accurate 7TMR/GPCR prediction tools is paramount with the accelerated rate of acquisition of diverse sequence information. Currently available and often used protein classification methods (e.g., profile hidden Markov Models) are highly accurate for identifying their membership information among already known 7TMR subfamilies. However, these alignment-based methods are less effective for identifying remote similarities, e.g., identifying proteins from highly divergent or possibly new 7TMR families. In this regard, more sensitive (e.g., alignment-free) methods are needed to complement the existing protein classification methods. A better strategy would be to combine different classifiers, from more specific to more sensitive methods, to identify a broader spectrum of 7TMR protein candidates. Description We developed a Web server, 7TMRmine, by integrating alignment-free and alignment-based classifiers specifically trained to identify candidate 7TMR proteins as well as transmembrane (TM) prediction methods. This new tool enables researchers to easily assess the distribution of GPCR functionality in diverse genomes or individual newly-discovered proteins. 7TMRmine is easily customized and facilitates exploratory analysis of diverse genomes. Users can integrate various alignment-based, alignment-free, and TM-prediction methods in any combination and in any hierarchical order. Sixteen classifiers (including two TM-prediction methods) are available on the 7TMRmine Web server. Not only can the 7TMRmine tool be used for 7TMR mining, but also for general TM-protein analysis. Users can submit protein sequences for analysis, or explore pre-analyzed results for multiple genomes. The server currently includes prediction results and the summary statistics for 68 genomes. Conclusion 7TMRmine facilitates the discovery of 7TMR proteins. By combining prediction results from different classifiers in a multi-level filtering process, prioritized sets of 7TMR candidates can be obtained for further investigation. 7TMRmine can be also used as a general TM-protein classifier. Comparisons of TM and 7TMR protein distributions among 68 genomes revealed interesting differences in evolution of these protein families among major eukaryotic phyla. PMID:19538753

  19. Cluster synthesis and direct ordering of rare-earth transition-metal nanomagnets.

    PubMed

    Balasubramanian, Balamurugan; Skomski, Ralph; Li, Xingzhong; Valloppilly, Shah R; Shield, Jeffrey E; Hadjipanayis, George C; Sellmyer, David J

    2011-04-13

    Rare-earth transition-metal (R-TM) alloys show superior permanent magnetic properties in the bulk, but the synthesis and application of R-TM nanoparticles remains a challenge due to the requirement of high-temperature annealing above about 800 °C for alloy formation and subsequent crystalline ordering. Here we report a single-step method to produce highly ordered R-TM nanoparticles such as YCo(5) and Y(2)Co(17), without high-temperature thermal annealing by employing a cluster-deposition system and investigate their structural and magnetic properties. The direct ordering is highly desirable to create and assemble R-TM nanoparticle building blocks for future permanent-magnet and other significant applications.

  20. Structural, Electronic and Elastic Properties of Heavy Fermion YbTM2 (TM= Ir and Pt) Laves Phase Compounds

    NASA Astrophysics Data System (ADS)

    Pawar, H.; Shugani, M.; Aynyas, M.; Sanyal, S. P.

    2018-02-01

    The structural, electronic and elastic properties of YbTM2 (TM = Ir and Pt) Laves phase intermetallic compounds which crystallize in cubic (MgCu2-type) structure, have been investigated using ab-initio full potential linearized augmented plane wave (FP-LAPW) method with LDA and LDA+U approximation. The calculated ground state properties such as lattice parameter (a0), bulk modulus (B) and its pressure derivative (B‧) are in good agreement with available experimental and theoretical data. The electronic properties are analyzed from band structures and density of states. Elastic constants are predicted first time for these compounds which obey the stability criteria for cubic system.

  1. High Energy Directly Pumped Ho:YLF Laser

    NASA Technical Reports Server (NTRS)

    Petros, Mulugeta; Yu, Ji-Rong; Singh, Upendra N.; Barnes, Norman P.

    2000-01-01

    The most commonly used crystal architecture to produce 2 micrometer laser is co-doping Ho and Tm into a single host crystal. In this method, the stored energy transfer from the Tm (3)F4 to the Ho (5)I7 manifold is not fast enough to warrant high efficiency for short pulse applications. By separating the Ho and the Tm ions and doping the Tm in YALO3 and the Ho in YLF, we were able to directly pump the Ho (5)I7 manifold with 1.94 micrometers. The Ho:YLF laser has produced 33 mJ at 2.062 micrometers with a quantum efficiency of 0.88. The performance of each laser will be presented.

  2. Traditional Medicine Collection Tracking System (TM-CTS): A Database for Ethnobotanically-Driven Drug-Discovery Programs

    PubMed Central

    Harris, Eric S. J.; Erickson, Sean D.; Tolopko, Andrew N.; Cao, Shugeng; Craycroft, Jane A.; Scholten, Robert; Fu, Yanling; Wang, Wenquan; Liu, Yong; Zhao, Zhongzhen; Clardy, Jon; Shamu, Caroline E.; Eisenberg, David M.

    2011-01-01

    Aim of the study. Ethnobotanically-driven drug-discovery programs include data related to many aspects of the preparation of botanical medicines, from initial plant collection to chemical extraction and fractionation. The Traditional Medicine-Collection Tracking System (TM-CTS) was created to organize and store data of this type for an international collaborative project involving the systematic evaluation of commonly used Traditional Chinese Medicinal plants. Materials and Methods. The system was developed using domain-driven design techniques, and is implemented using Java, Hibernate, PostgreSQL, Business Intelligence and Reporting Tools (BIRT), and Apache Tomcat. Results. The TM-CTS relational database schema contains over 70 data types, comprising over 500 data fields. The system incorporates a number of unique features that are useful in the context of ethnobotanical projects such as support for information about botanical collection, method of processing, quality tests for plants with existing pharmacopoeia standards, chemical extraction and fractionation, and historical uses of the plants. The database also accommodates data provided in multiple languages and integration with a database system built to support high throughput screening based drug discovery efforts. It is accessed via a web-based application that provides extensive, multi-format reporting capabilities. Conclusions. This new database system was designed to support a project evaluating the bioactivity of Chinese medicinal plants. The software used to create the database is open source, freely available, and could potentially be applied to other ethnobotanically-driven natural product collection and drug-discovery programs. PMID:21420479

  3. A mutant screening method by critical annealing temperature-PCR for site-directed mutagenesis.

    PubMed

    Liu, Ying; Wu, Ting; Song, Jian; Chen, Xuelian; Zhang, Yu; Wan, Yu

    2013-03-11

    Distinguishing desired mutants from parental templates and undesired mutants is a problem not well solved in Quikchange™ mutagenesis. Although Dpn I digestion can eliminate methylated parental (WT) DNA, the efficiency is not satisfying due to the existence of hemi-methylated DNA in the PCR products, which is resistant to Dpn I. The present study designed a novel critical annealing temperature (T(c))-PCR to replace Dpn I digestion for more perfect mutant distinguishing, in which part-overlapping primers containing mutation(s) were used to reduce initial concentration of template DNA in mutagenic PCR. A T(c)-PCR with the same mutagenic primers was performed without Dpn I digestion. The T(c) for each pair of the primers was identified by gradient PCR. The relationship between PCR-identified T(c) and T(m) of the primers was analyzed and modeled with correlation and regression. Gradient PCR identified a T(c) for each of 14 tested mutagenic primers, which could discriminate mismatched parental molecules and undesired mutants from desired mutants. The PCR-identified T(c) was correlated to the primer's T(m) (r = 0.804, P<0.0001). Thus, in practical applications, the T(c) can be easily calculated with a regression equation, T(c)= 48.81 + 0.253*T(m). The new protocol introduced a novel T(c)-PCR method for mutant screening which can more efficiently and accurately select against parental molecules and undesired mutations in mutagenic sequence segments.

  4. Dorsoradial capsulodesis for trapeziometacarpal joint instability.

    PubMed

    Rayan, Ghazi; Do, Viet

    2013-02-01

    We describe an alternative method for treating chronic trapeziometacarpal (TM) joint instability after acute injury or chronic repetitive use of the thumb by performing a dorsoradial capsulodesis procedure. The procedure is done by imbricating the redundant TM joint dorsoradial ligament and capsule after reducing the joint by pronating the thumb. The dorsoradial capsulodesis is a reasonable reconstructive option for chronic TM joint instability and subluxation. Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  5. Fabrication and evaluation of chitosan/NaYF4:Yb3+/Tm3+ upconversion nanoparticles composite beads based on the gelling of Pickering emulsion droplets.

    PubMed

    Yan, Huiqiong; Chen, Xiuqiong; Shi, Jia; Shi, Zaifeng; Sun, Wei; Lin, Qiang; Wang, Xianghui; Dai, Zihao

    2017-02-01

    The rare earth ion doped upconversion nanoparticles (UCNPs) synthesized by hydrophobic organic ligands possess poor solubility and low fluorescence quantum yield in aqueous media. To conquer this issue, NaYF 4 :Yb 3+ /Tm 3+ UCNPs, synthesized by a hydrothermal method, were coated with F127 and then assembled with chitosan to fabricate the chitosan/NaYF 4 :Yb 3+ /Tm 3+ composite beads (CS/NaYF 4 :Yb 3+ /Tm 3+ CBs) by Pickering emulsion system. The characterization results revealed that the as-synthesized NaYF 4 :Yb 3+ /Tm 3+ UCNPs with an average size of 20nm exhibited spherical morphology, high crystallinity and characteristic emission upconversion fluorescence with an overall blue color output. The NaYF 4 :Yb 3+ /Tm 3+ UCNPs were successfully conjugated on the surface of chitosan beads by the gelling of emulsion droplets. The resultant CS/NaYF 4 :Yb 3+ /Tm 3+ CBs showed good upconversion luminescent property, drug-loading capacity, release performance and excellent biocompatibility, exhibiting great potentials in targeted drug delivery and tissue engineering with potential tracking capability and lasting release performance. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Physiological patterns during practice of the Transcendental Meditation technique compared with patterns while reading Sanskrit and a modern language.

    PubMed

    Travis, F; Olson, T; Egenes, T; Gupta, H K

    2001-07-01

    This study tested the prediction that reading Vedic Sanskrit texts, without knowledge of their meaning, produces a distinct physiological state. We measured EEG, breath rate, heart rate, and skin conductance during: (1) 15-min Transcendental Meditation (TM) practice; (2) 15-min reading verses of the Bhagavad Gita in Sanskrit; and (3) 15-min reading the same verses translated in German, Spanish, or French. The two reading conditions were randomly counterbalanced, and subjects filled out experience forms between each block to reduce carryover effects. Skin conductance levels significantly decreased during both reading Sanskrit and TM practice, and increased slightly during reading a modern language. Alpha power and coherence were significantly higher when reading Sanskrit and during TM practice, compared to reading modern languages. Similar physiological patterns when reading Sanskrit and during practice of the TM technique suggests that the state gained during TM practice may be integrated with active mental processes by reading Sanskrit.

  7. Mobile phone use patterns and preferences in safety net office-based buprenorphine patients

    PubMed Central

    Tofighi, Babak; Grossman, Ellie; Buirkle, Emily; McNeely, Jennifer; Gourevitch, Marc; Lee, Joshua D.

    2015-01-01

    Background Integrating mobile phone technologies in addiction treatment is of increasing importance, and may optimize patient engagement with their care and enhance the delivery of existing treatment strategies. Few studies have evaluated mobile phone and text message (TM) use patterns in persons enrolled in addiction treatment, and none have assessed use in safety net, office-based buprenorphine practices. Methods A 28-item, quantitative and qualitative semi-structured survey was administered to opiate-dependent adults in an urban, publicly funded, office-based buprenorphine program. Survey domains included: demographic characteristics, mobile phone and TM use patterns, and mobile phone and TM use patterns and preferences pertaining to their recovery. Results Surveyors approached 73 of the 155 eligible subjects (47%); 71 respondents completed the survey. Nearly all participants reported mobile phone ownership (93%) and TM use (93%), and most reported ‘very much’ or ‘somewhat’ comfort sending TM (79%). TM contact with 12-step group sponsors, friends, family members, and counselors was also described (32%). Nearly all preferred having their providers’ mobile phone number (94%) and alerting the clinic via TM in the event of a potential relapse to receive both supportive TM and a phone call from their buprenorphine provider was also well received (62%). Conclusions Mobile phone and TM use patterns and preferences among this sample of office-based buprenorphine participants highlight the potential of adopting patient-centered mobile phone based interventions in this treatment setting. PMID:25918966

  8. Failure Mode Classification for Life Prediction Modeling of Solid-State Lighting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sakalaukus, Peter Joseph

    2015-08-01

    Since the passing of the Energy Independence and Security Act of 2007, the U.S. government has mandated greater energy independence which has acted as a catalyst for accelerating and facilitating research efforts toward the development and deployment of market-driven solutions for energy-saving homes, buildings and manufacturing, as well as sustainable transportation and renewable electricity generation. As part of this effort, an emphasis toward advancing solid-state lighting technology through research, development, demonstration, and commercial applications is assisting in the phase out of the common incandescent light bulb, as well as developing a more economical lighting source that is less toxic thanmore » compact fluorescent lighting. This has led lighting manufacturers to pursue SSL technologies for a wide range of consumer lighting applications. An SSL luminaire’s lifetime can be characterized in terms of lumen maintenance life. Lumen maintenance or lumen depreciation is the percentage decrease in the relative luminous flux from that of the original, pristine luminous flux value. Lumen maintenance life is the estimated operating time, in hours, when the desired failure threshold is projected to be reached at normal operating conditions. One accepted failure threshold of SSL luminaires is lumen maintenance of 70% -- a 30% reduction in the light output of the luminaire. Currently, the only approved lighting standard that puts forth a recommendation for long-term luminous flux maintenance projections towards a specified failure threshold of an SSL luminaire is the IES TM-28-14 (TM28) standard. iii TM28 was derived as a means to compare luminaires that have been tested at different facilities, research labs or companies. TM28 recommends the use of the Arrhenius equation to determine SSL device specific reaction rates from thermally driven failure mechanisms used to characterize a single failure mode – the relative change in the luminous flux output or “light power” of the SSL luminaire. The use of the Arrhenius equation necessitates two different temperature conditions, 25°C and 45°C are suggested by TM28, to determine the SSL lamp specific activation energy. One principal issue with TM28 is the lack of additional stresses or parameters needed to characterize non-temperature dependent failure mechanisms. Another principal issue with TM28 is the assumption that lumen maintenance or lumen depreciation gives an adequate comparison between SSL luminaires. Additionally, TM28 has no process for the determination of acceleration factors or lifetime estimations. Currently, a literature gap exists for established accelerated test methods for SSL devices to assess quality, reliability and durability before being introduced into the marketplace. Furthermore, there is a need for Physics-of-Failure based approaches to understand the processes and mechanisms that induce failure for the assessment of SSL reliability in order to develop generalized acceleration factors that better represent SSL product lifetime. This and the deficiencies in TM28 validate the need behind the development of acceleration techniques to quantify SSL reliability under a variety of environmental conditions. The ability to assess damage accrual and investigate reliability of SSL components and systems is essential to understanding the life time of the SSL device itself. The methodologies developed in this work increases the understanding of SSL devices iv through the investigation of component and device reliability under a variety of accelerated test conditions. The approaches for suitable lifetime predictions through the development of novel generalized acceleration factors, as well as a prognostics and health management framework, will greatly reduce the time and effort needed to produce SSL acceleration factors for the development of lifetime predictions.« less

  9. Feasibility study using MRI and two optical CT scanners for readout of polymer gel and PresageTM

    NASA Astrophysics Data System (ADS)

    Svensson, H.; Skyt, P. S.; Ceberg, S.; Doran, S.; Muren, L. P.; Balling, P.; Petersen, J. B. B.; Bäck, S. Å. J.

    2013-06-01

    The aim of this study was to compare the conventional combination of three-dimensional dosimeter (nPAG gel) and readout method (MRI) with other combinations of three-dimensional dosimeters (nPAG gel/PresageTM) and readout methods (optical CT scanners). In the first experiment, the dose readout of a gel irradiated with a four field-box technique was performed with both an Octopus IQ scanner and MRI. It was seen that the MRI readout agreed slightly better to the TPS. In another experiment, a gel and a PresageTM sample were irradiated with a VMAT field and read out using MRI and a fast laser scanner, respectively. A comparison between the TPS and the volumes revealed that the MRI/gel readout had closer resemblance to the TPS than the optical CT/PresageTM readout. There are clearly potential in the evaluated optical CT scanners, but more time has to be invested in the particular scanning scenario than was possible in this study.

  10. Aqueous liquid feed organic fuel cell using solid polymer electrolyte membrane

    NASA Technical Reports Server (NTRS)

    Olah, George A. (Inventor); Surampudi, Subbarao (Inventor); Vamos, Eugene (Inventor); Halpert, Gerald (Inventor); Narayanan, Sekharipuram R. (Inventor); Frank, Harvey A. (Inventor); Prakash, G. K. Surya (Inventor)

    1997-01-01

    A liquid organic fuel cell is provided which employs a solid electrolyte membrane. An organic fuel, such as a methanol/water mixture, is circulated past an anode of a cell while oxygen or air is circulated past a cathode of the cell. The cell solid electrolyte membrane is preferably fabricated from Nafion.TM.. Additionally, a method for improving the performance of carbon electrode structures for use in organic fuel cells is provided wherein a high surface-area carbon particle/Teflon.TM.-binder structure is immersed within a Nafion.TM./methanol bath to impregnate the electrode with Nafion.TM.. A method for fabricating an anode for use in a organic fuel cell is described wherein metal alloys are deposited onto the electrode in an electro-deposition solution containing perfluorooctanesulfonic acid. A fuel additive containing perfluorooctanesulfonic acid for use with fuel cells employing a sulfuric acid electrolyte is also disclosed. New organic fuels, namely, trimethoxymethane, dimethoxymethane, and trioxane are also described for use with either conventional or improved fuel cells.

  11. Validation of a single-platform method for hematopoietic CD34+ stem cells enumeration according to accreditation procedure.

    PubMed

    Massin, Frédéric; Huili, Cai; Decot, Véronique; Stoltz, Jean-François; Bensoussan, Danièle; Latger-Cannard, Véronique

    2015-01-01

    Stem cells for autologous and allogenic transplantation are obtained from several sources including bone marrow, peripheral blood or cord blood. Accurate enumeration of viable CD34+ hematopoietic stem cells (HSC) is routinely used in clinical settings, especially to monitor progenitor cell mobilization and apheresis. The number of viable CD34+ HSC has also been shown to be the most critical factor in haematopoietic engraftment. The International Society for Cellular Therapy actually recommends the use of single-platform flow cytometry system using 7-AAD as a viability dye. In a way to move routine analysis from a BD FACSCaliburTM instrument to a BD FACSCantoTM II, according to ISO 15189 standard guidelines, we define laboratory performance data of the BDTM Stem Cell Enumeration (SCE) kit on a CE-IVD system including a BD FACSCanto II flow cytometer and the BD FACSCantoTM Clinical Software. InterQCTM software, a real time internet laboratory QC management system developed by VitroTM and distributed by Becton DickinsonTM, was also tested to monitor daily QC data, to define the internal laboratory statistics and to compare them to external laboratories. Precision was evaluated with BDTM Stem Cell Control (high and low) results and the InterQC software, an internet laboratory QC management system by Vitro. This last one drew Levey-Jennings curves and generated numeral statistical parameters allowing detection of potential changes in the system performances as well as interlaboratory comparisons. Repeatability, linearity and lower limits of detection were obtained with routine samples from different origins. Agreement evaluation between BD FACSCanto II system versus BD FACSCalibur system was tested on fresh peripheral blood, freeze-thawed apheresis, fresh bone marrow and fresh cord blood samples. Instrument's measure and staining repeatability clearly evidenced acceptable variability on the different samples tested. Intra- and inter-laboratory CV in CD34+ cell absolute count are consistent and reproducible. Linearity analysis, established between 2 and 329 cells/μl showed a linear relation between expected counts and measured counts (R2=0.97). Linear regression and Bland-Altman representations showed an excellent correlation on samples from different sources between the two systems and allowed the transfer of routine analysis from BD FACSCalibur to BD FACSCanto II. The BD SCE kit provides an accurate measure of the CD34 HSC, and can be used in daily routine to optimize the enumeration of hematopoietic CD34+ stem cells by flow cytometry. Moreover, the InterQC system seems to be a very useful tool for laboratory daily quality monitoring and thus for accreditation.

  12. Design and rationale of a comparative effectiveness trial evaluating transcendental meditation against established therapies for PTSD.

    PubMed

    Rutledge, Thomas; Nidich, Sanford; Schneider, Robert H; Mills, Paul J; Salerno, John; Heppner, Pia; Gomez, Mayra A; Gaylord-King, Carolyn; Rainforth, Maxwell

    2014-09-01

    Although meditation therapies such as the Transcendental Meditation (TM) technique are commonly used to assist with stress and stress-related diseases, there remains a lack of rigorous clinical trial research establishing the relative efficacy of these treatments overall and for populations with psychiatric illness. This study uses a comparative effectiveness design to assess the relative benefits of TM to those obtained from a gold-standard cognitive behavioral therapy for posttraumatic stress disorder (PTSD) in a Veteran population. This paper describes the rationale and design of an in progress randomized controlled trial comparing TM to an established cognitive behavioral treatment - Prolonged Exposure (PE) - and an active control condition (health education [HE]) for PTSD. This trial will recruit 210 Veterans meeting DSM-IV criteria for PTSD, with testing conducted at 0 and 3 months for PTSD symptoms, depression, mood disturbance, quality of life, behavioral factors, and physiological/biochemical and gene expression mechanisms using validated measures. The study hypothesis is that TM will be noninferior to PE and superior to HE on changes in PTSD symptoms, using the Clinician Administered PTSD Scale (CAPS). The described study represents a methodologically rigorous protocol evaluating the benefits of TM for PTSD. The projected results will help to establish the overall efficacy of TM for PTSD among Veterans, identify bio-behavioral mechanisms through which TM and PE may improve PTSD symptoms, and will permit conclusions regarding the relative value of TM against currently established therapies for PTSD. Published by Elsevier Inc.

  13. An approach for detecting five typical vegetation types on the Chinese Loess Plateau using Landsat TM data.

    PubMed

    Wang, Zhi-Jie; Jiao, Ju-Ying; Lei, Bo; Su, Yuan

    2015-09-01

    Remote sensing can provide large-scale spatial data for the detection of vegetation types. In this study, two shortwave infrared spectral bands (TM5 and TM7) and one visible spectral band (TM3) of Landsat 5 TM data were used to detect five typical vegetation types (communities dominated by Bothriochloa ischaemum, Artemisia gmelinii, Hippophae rhamnoides, Robinia pseudoacacia, and Quercus liaotungensis) using 270 field survey data in the Yanhe watershed on the Loess Plateau. The relationships between 200 field data points and their corresponding radiance reflectance were analyzed, and the equation termed the vegetation type index (VTI) was generated. The VTI values of five vegetation types were calculated, and the accuracy was tested using the remaining 70 field data points. The applicability of VTI was also tested by the distribution of vegetation type of two small watersheds in the Yanhe watershed and field sample data collected from other regions (Ziwuling Region, Huangling County, and Luochuan County) on the Loess Plateau. The results showed that the VTI can effectively detect the five vegetation types with an average accuracy exceeding 80 % and a representativeness above 85 %. As a new approach for monitoring vegetation types using remote sensing at a larger regional scale, VTI can play an important role in the assessment of vegetation restoration and in the investigation of the spatial distribution and community diversity of vegetation on the Loess Plateau.

  14. 1887 nm lasing in Tm3+-doped TeO2-BaF2-Y2O3 glass microstructured fibers

    NASA Astrophysics Data System (ADS)

    Wang, Shunbin; Yao, Chuanfei; Jia, Zhixu; Qin, Guanshi; Qin, Weiping

    2017-04-01

    In this paper, we demonstrate ∼2 μm lasing in Tm3+-doped fluorotellurite microstructured fibers. The Tm3+-doped fibers are based on TeO2-BaF2-Y2O3 glasses and fabricated by using a rod-in-tube method. Under the pump of a 1570 nm Er3+-doped fiber laser, lasing at 1887 nm is obtained in a ∼42.5 cm long Tm3+-doped fiber with a threshold pump power of 94 mW. As the pump power increases to 780 mW, the obtained maximum unsaturated power reaches up to ∼408 mW with a slop efficiency of ∼58.1%. This result indicates that the Tm3+-doped fluorotellurite fibers are promising gain media for ∼2 μm fiber lasers.

  15. Phase 2: Array automated assembly task low cost silicon solar array project

    NASA Technical Reports Server (NTRS)

    Jones, G. T.

    1979-01-01

    Several microwave systems for use in solar cell fabrication were developed and experimentally tested. The first system used a standing wave rectangular waveguide horn applicator. Satisfactory results were achieved with this system for impedance matching and wafer surface heating uniformity. The second system utilized a resonant TM sub 011 mode cylindrical cavity but could not be employed due to its poor energy coupling efficiency. The third and fourth microwave systems utilized a circular waveguide operating in the TM sub 01 and TM sub 11 but had problems with impedance matching, efficiency, and field uniformity.

  16. Army Oil Analysis Program for Vehicle Testing

    DTIC Science & Technology

    1996-08-16

    4 TOP 2-2-690 16 August 1996 (l) Water determination: Karl Fischer method (TM 38-301-2 or ASTM-D1744 3 ): Set up the Karl Fischer titrator in...higher temperature if required. aMagnification. bReflected. CTransmitted. 5. DATA REQUIRED. a. Water: Karl Fischer percent water-- (% H2 0). b...Liquid Petroleum Products by Karl Fischer Reagent, 1984. 4. DL 18, Karl Fischer Titrator Operating Instructions. 5. ASTM-D445, Annual Book of ASTM

  17. ENVIRONMENTAL TECHNOLOGY VERIFICATION: JOINT (NSF-EPA) VERIFICATION STATEMENT AND REPORT HYDRO COMPLIANCE MANAGEMENT, INC. HYDRO-KLEEN FILTRATION SYSTEM, 03/07/WQPC-SWP, SEPTEMBER 2003

    EPA Science Inventory

    Verification testing of the Hydro-Kleen(TM) Filtration System, a catch-basin filter designed to reduce hydrocarbon, sediment, and metals contamination from surface water flows, was conducted at NSF International in Ann Arbor, Michigan. A Hydro-Kleen(TM) system was fitted into a ...

  18. Landsat TM Classifications For SAFIS Using FIA Field Plots

    Treesearch

    William H. Cooke; Andrew J. Hartsell

    2001-01-01

    Wall-to-wall Landsat Thematic Mapper (TM) classification efforts in Georgia require field validation. We developed a new crown modeling procedure based on Forest Health Monitoring (FHM) data to test Forest Inventory and Analysis (FIA) data. These models simulate the proportion of tree crowns that reflect light on a FIA subplot basis. We averaged subplot crown...

  19. Clinical trial to compare tinnitus masking and tinnitus retraining therapy.

    PubMed

    Henry, J A; Schechter, M A; Zaugg, T L; Griest, S; Jastreboff, P J; Vernon, J A; Kaelin, C; Meikle, M B; Lyons, K S; Stewart, B J

    2006-12-01

    Both tinnitus masking (TM) and tinnitus retraining therapy (TRT) can be effective therapies for amelioration of tinnitus. TM may be more effective for patients in the short term, but with continued treatment TRT may produce the greatest effects. Although TM and TRT have been used for many years, research has not documented definitively the efficacy of these methods. The present study was a controlled clinical trial to prospectively evaluate the clinical efficacy of these two methods for US military veterans with severe tinnitus. Over 800 veterans were screened to ensure that enrolled patients had tinnitus of sufficient severity to justify 18 months of individualized treatment. Qualifying patients (n=123) were placed quasi-randomly (alternating placement) into treatment with either TM or TRT. Treatment was administered at 0, 3, 6, 12, and 18 months. Outcomes of treatment were evaluated primarily using three self-administered tinnitus questionnaires (Tinnitus Handicap Inventory, Tinnitus Handicap Questionnaire, Tinnitus Severity Index). Findings are presented from the three written questionnaires with respect to three categories of patients: describing tinnitus as a 'moderate,' 'big,' and 'very big' problem at baseline. Based on effect sizes, both groups showed considerable improvement overall. In general, TM effects remained fairly constant over time while TRT effects improved incrementally. For the patients with a 'moderate' and 'big' problem, TM provided the greatest benefit at 3 and 6 months; benefit to these TRT patients was slightly greater at 12 months, and much greater at 18 months. For patients with a 'very big' problem, TM provided the greatest benefit at 3 months. For these latter patients, results were about the same between groups at 6 months, and improvement for TRT was much greater at 12 months, with further gains at 18 months.

  20. A two-stage cluster sampling method using gridded population data, a GIS, and Google Earth(TM) imagery in a population-based mortality survey in Iraq.

    PubMed

    Galway, Lp; Bell, Nathaniel; Sae, Al Shatari; Hagopian, Amy; Burnham, Gilbert; Flaxman, Abraham; Weiss, Wiliam M; Rajaratnam, Julie; Takaro, Tim K

    2012-04-27

    Mortality estimates can measure and monitor the impacts of conflict on a population, guide humanitarian efforts, and help to better understand the public health impacts of conflict. Vital statistics registration and surveillance systems are rarely functional in conflict settings, posing a challenge of estimating mortality using retrospective population-based surveys. We present a two-stage cluster sampling method for application in population-based mortality surveys. The sampling method utilizes gridded population data and a geographic information system (GIS) to select clusters in the first sampling stage and Google Earth TM imagery and sampling grids to select households in the second sampling stage. The sampling method is implemented in a household mortality study in Iraq in 2011. Factors affecting feasibility and methodological quality are described. Sampling is a challenge in retrospective population-based mortality studies and alternatives that improve on the conventional approaches are needed. The sampling strategy presented here was designed to generate a representative sample of the Iraqi population while reducing the potential for bias and considering the context specific challenges of the study setting. This sampling strategy, or variations on it, are adaptable and should be considered and tested in other conflict settings.

  1. A two-stage cluster sampling method using gridded population data, a GIS, and Google EarthTM imagery in a population-based mortality survey in Iraq

    PubMed Central

    2012-01-01

    Background Mortality estimates can measure and monitor the impacts of conflict on a population, guide humanitarian efforts, and help to better understand the public health impacts of conflict. Vital statistics registration and surveillance systems are rarely functional in conflict settings, posing a challenge of estimating mortality using retrospective population-based surveys. Results We present a two-stage cluster sampling method for application in population-based mortality surveys. The sampling method utilizes gridded population data and a geographic information system (GIS) to select clusters in the first sampling stage and Google Earth TM imagery and sampling grids to select households in the second sampling stage. The sampling method is implemented in a household mortality study in Iraq in 2011. Factors affecting feasibility and methodological quality are described. Conclusion Sampling is a challenge in retrospective population-based mortality studies and alternatives that improve on the conventional approaches are needed. The sampling strategy presented here was designed to generate a representative sample of the Iraqi population while reducing the potential for bias and considering the context specific challenges of the study setting. This sampling strategy, or variations on it, are adaptable and should be considered and tested in other conflict settings. PMID:22540266

  2. Improvement of blood compatibility on polysulfone-polyvinylpyrrolidone blend films as a model membrane of dialyzer by physical adsorption of recombinant soluble human thrombomodulin (ART-123).

    PubMed

    Omichi, Masaaki; Matsusaki, Michiya; Maruyama, Ikuro; Akashi, Mitsuru

    2012-01-01

    ART-123 is a recombinant soluble human thrombomodulin (hTM) with potent anticoagulant activity, and is available for developing antithrombogenic surfaces by immobilization. We focused on improving blood compatibility on the dialyzer surface by the physical adsorption of ART-123 as a safe yet simple method without using chemical reagents. The physical adsorption mechanism and anticoagulant activities of adsorbed hTM on the surface of a polysulfone (PSF) membrane containing polyvinylpyrrolidone (PVP) as a model dialyzer were investigated in detail. The PVP content of the PSF-PVP films was saturated at 20 wt% after immersion in Tris-HCl buffer, even with the addition of over 20 wt% PVP. The surface morphology of the PSF-PVP films was strongly influenced by the PVP content, because PVP covered the outermost surface of the PSF-PVP films. The adsorption speed of hTM slowed dramatically with increasing PVP content up to 10 wt%, but the maximum adsorption amount of hTM onto the PSF-PVP film surface was almost the same, regardless of the PVP content. The PSF-PVP film with the physically adsorbed hTM showed higher protein C activity as compared to the PSF film, it showed excellent blood compatibility due to the protein C activity and the inhibition properties of platelet adhesion. The physical adsorption of hTM can be useful as a safe yet simple method to improve the blood compatibility of a dialyzer surface.

  3. ∼2 μm emission properties and non-radiative processes of Tm{sup 3+} in germanate glass

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gao, Song; Liu, Xueqiang; Fan, Xiaokang

    2014-11-07

    In this paper, 80GeO{sub 2}-8Ga{sub 2}O{sub 3}-10BaO-2Nb{sub 2}O{sub 5}-6PbO (in mol%) glass samples with different Tm{sub 2}O{sub 3} concentrations (0, 0.5, 0.75, 1, 1.25, and 1.5 mol. %) were prepared by traditional melt-quenching method. According to the measurement of thermal properties of the host glass, the glass transition temperature is 596.7 °C and no crystallization peak is observed. Judd–Ofelt parameters Ω{sub t} (t = 2, 4, 6) and fluorescent lifetimes were obtained by Judd-Ofelt theory. The similar values of Judd–Ofelt parameters and the full-width at half-maximums of ∼1800 nm indicate the local environment of Tm{sup 3+} changes little with increment of Tm{sub 2}O{sub 3} concentrations.more » Maximum stimulated emission cross-section of ∼1800 nm is 6.22 × 10{sup −21} cm{sup 2} as calculated by Fuchtbauer–Ladenburg formula. Energy migration among Tm{sup 3+} ions was analyzed by the extended overlap integral method. The non-radiative transition rates between mainly energy levels of Tm{sup 3+} were calculated. Non-radiative transition rate of {sup 3}F{sub 4} energy level caused by OH was analyzed by rate equation and deduced by fitting the fluorescence decay curve.« less

  4. What Scientific Applications can Benefit from Hardware Transactional Memory?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schindewolf, M; Bihari, B; Gyllenhaal, J

    2012-06-04

    Achieving efficient and correct synchronization of multiple threads is a difficult and error-prone task at small scale and, as we march towards extreme scale computing, will be even more challenging when the resulting application is supposed to utilize millions of cores efficiently. Transactional Memory (TM) is a promising technique to ease the burden on the programmer, but only recently has become available on commercial hardware in the new Blue Gene/Q system and hence the real benefit for realistic applications has not been studied, yet. This paper presents the first performance results of TM embedded into OpenMP on a prototype systemmore » of BG/Q and characterizes code properties that will likely lead to benefits when augmented with TM primitives. We first, study the influence of thread count, environment variables and memory layout on TM performance and identify code properties that will yield performance gains with TM. Second, we evaluate the combination of OpenMP with multiple synchronization primitives on top of MPI to determine suitable task to thread ratios per node. Finally, we condense our findings into a set of best practices. These are applied to a Monte Carlo Benchmark and a Smoothed Particle Hydrodynamics method. In both cases an optimized TM version, executed with 64 threads on one node, outperforms a simple TM implementation. MCB with optimized TM yields a speedup of 27.45 over baseline.« less

  5. Spectral transformation of ASTER and Landsat TM bands for lithological mapping of Soghan ophiolite complex, south Iran

    NASA Astrophysics Data System (ADS)

    Pournamdari, Mohsen; Hashim, Mazlan; Pour, Amin Beiranvand

    2014-08-01

    Spectral transformation methods, including correlation coefficient (CC) and Optimum Index Factor (OIF), band ratio (BR) and principal component analysis (PCA) were applied to ASTER and Landsat TM bands for lithological mapping of Soghan ophiolitic complex in south of Iran. The results indicated that the methods used evidently showed superior outputs for detecting lithological units in ophiolitic complexes. CC and OIF methods were used to establish enhanced Red-Green-Blue (RGB) color combination bands for discriminating lithological units. A specialized band ratio (4/1, 4/5, 4/7 in RGB) was developed using ASTER bands to differentiate lithological units in ophiolitic complexes. The band ratio effectively detected serpentinite dunite as host rock of chromite ore deposits from surrounding lithological units in the study area. Principal component images derived from first three bands of ASTER and Landsat TM produced well results for lithological mapping applications. ASTER bands contain improved spectral characteristics and higher spatial resolution for detecting serpentinite dunite in ophiolitic complexes. The developed approach used in this study offers great potential for lithological mapping using ASTER and Landsat TM bands, which contributes in economic geology for prospecting chromite ore deposits associated with ophiolitic complexes.

  6. Comparison between refraction measured by Spot Vision ScreeningTM and subjective clinical refractometry

    PubMed Central

    de Jesus, Daniela Lima; Villela, Flávio Fernandes; Orlandin, Luis Fernando; Eiji, Fernando Naves; Dantas, Daniel Oliveira; Alves, Milton Ruiz

    2016-01-01

    OBJECTIVE: The purpose of this study was to evaluate the accuracy of Spot Vision ScreeningTM as an autorefractor by comparing refraction measurements to subjective clinical refractometry results in children and adult patients. METHODS: One-hundred and thirty-four eyes of 134 patients were submitted to refractometry by Spot and clinical refractometry under cycloplegia. Patients, students, physicians, staff and children of staff from the Hospital das Clínicas (School of Medicine, University of São Paulo) aged 7-50 years without signs of ocular disease were examined. Only right-eye refraction data were analyzed. The findings were converted in magnitude vectors for analysis. RESULTS: The difference between Spot Vision ScreeningTM and subjective clinical refractometry expressed in spherical equivalents was +0.66±0.56 diopters (D), +0.16±0.27 D for the vector projected on the 90 axis and +0.02±0.15 D for the oblique vector. CONCLUSIONS: Despite the statistical significance of the difference between the two methods, we consider the difference non-relevant in a clinical setting, supporting the use of Spot Vision ScreeningTM as an ancillary method for estimating refraction. PMID:26934234

  7. Executive Function, Survival, and Hospitalization in Chronic Obstructive Pulmonary Disease. A Longitudinal Analysis of the National Emphysema Treatment Trial (NETT)

    PubMed Central

    Dodd, James W.; Novotny, Paul; Sciurba, Frank C.

    2015-01-01

    Rationale: Cognitive dysfunction has been demonstrated in chronic obstructive pulmonary disease (COPD), but studies are limited to cross-sectional analyses or incompletely characterized populations. Objectives: We examined longitudinal changes in sensitive measures of executive function in a well-characterized population of patients with severe COPD. Methods: This study was performed on patients enrolled in the National Emphysema Treatment Trial. To assess executive function, we analyzed trail making (TM) A and B times at enrollment in the trial (2,128 patients), and at 12 (731 patients) and 24 months (593 patients) after enrollment, adjusted for surgery, marriage status, age, education, income, depression, PaO2, PaCO2, and smoking. Associations with survival and hospitalizations were examined using Cox regression and linear regression models. Measurements and Main Results: The average age of the patients was 66.4 years, and the average FEV1 was 23.9% predicted. At the time of enrolment, 38% had executive dysfunction. Compared with those who did not, these patients were older, less educated, had higher oxygen use, higher PaCO2, worse quality of life as measured by the St. George’s Respiratory Quotient, reduced well-being, and lower social function. There was no significant change over 2 years in TM A or B times after adjustment for covariables. Changes in TM B times were modestly associated with survival, but changes in TM B − A times were not. Changes in TM scores were not associated with frequency of hospitalization. Lung function, PaO2, smoking, survival, and hospitalizations were not significantly different in those with executive dysfunction. Conclusions: In this large population of patients with severe emphysema and heavy cigarette smoking exposure, there was no significant decline over 2 years in cognitive executive function as measured by TM tests. There was no association between executive function impairment and frequency of hospitalization, and there was a possible modest association with survival. It is plausible that cerebrovascular comorbidities explain previously described cognitive pathology in COPD. PMID:26288391

  8. Spectroscopy and lasing of Tm:SrMoO4 crystal near 1.5, 1.9, and 2.3-μm under 793-nm excitation

    NASA Astrophysics Data System (ADS)

    Šulc, Jan; Švejkar, Richard; Němec, Michal; Doroshenko, Maxim E.; Jelínková, Helena; Ivleva, Liudmila I.; Dunaeva, Elizaveta E.

    2018-02-01

    The spectroscopy properties and lasing of diode pumped Tm-doped strontium molybdate SrMoO4 single crystal were investigated at room temperature. The Tm:SrMoO4 crystal was grown by modified Stepanov method (2 wt.% of TmNbO4 in the melt). The tested Tm:SrMoO4 sample was cut from the grown crystal boule perpendicularly to growth direction 100. For spectroscopy and laser experiments 4.2mm thick plane-parallel face-polished plate (without AR coatings) was used. A fiber-coupled laser diode operating at wavelength 793nm was used for longitudinal Tm:SrMoO4 pumping which corresponds to 3H4 level excitation. Fluorescence spectra measurement showed strong emission in vicinity of 1.8 μm (3F4 -> 3H6 transition), and also significant emission close to wavelengths 1.45 μm (3H4 -> 3F4 transition) and 2.3 μm (3H4 -> 3H5 transition). The lasing was successfully reached for all these three transitions and output characteristics were measured. The pumping laser diode was operating in the pulsed regime with a low duty cycle. The 145mm long semi-hemispherical laser resonator consisted of flat pumping mirror (HT @ 0.79 μm) and curved (r = 150mm) output coupler. For each lasing transition the particular set of resonator mirrors was used to reach high reflexivity of pumping mirror and output coupler transmission 0.5% at laser operation wavelength. The obtained laser emission wavelengths were 1.95 μm, 1.45 & 1.49 μm, and 2.30 μm. In spite of low laser slope efficiency in respect to absorbed pumping power (0.45% for 3H4 -> 3F4 transition, 0.50% for 3F4 -> 3H6 transition and 0.83% for 3H4 -> 3H5 transition), results obtained are promising for further development of diode-pumped laser at 2.3 μm spectral region.

  9. Containerless Processing in Reduced Gravity Using the TEMPUS Facility

    NASA Technical Reports Server (NTRS)

    Roger, Jan R.; Robinson, Michael B.

    1996-01-01

    Containerless processing provides a high purity environment for the study of high-temperature, very reactive materials. It is an important method which provides access to the metastable state of an undercooled melt. In the absence of container walls, the nucleation rate is greatly reduced and undercooling up to (Tm-Tn)/Tm approx. 0.2 can be obtained, where Tm and Tn are the melting and nucleation temperatures, respectively. Electromagnetic levitation represents a method particularly well-suited for the study of metallic melts. The TEMPUS facility is a research instrument designed to perform electromagnetic levitation studies in reduced gravity. It provides temperatures up to 2600 C, levitation of several grams of material and access to the undercooled state for an extended period of time (up to hours).

  10. Sequence diversity within the HA-1 gene as detected by melting temperature assay without oligonucleotide probes

    PubMed Central

    Graziano, Claudio; Giorgi, Massimo; Malentacchi, Cecilia; Mattiuz, Pier Luigi; Porfirio, Berardino

    2005-01-01

    Background The minor histocompatibility antigens (mHags) are self-peptides derived from common cellular proteins and presented by MHC class I and II molecules. Disparities in mHags are a potential risk for the development of graft-versus-host disease (GvHD) in the recipients of bone marrow from HLA-identical donors. Two alleles have been identified in the mHag HA-1. The correlation between mismatches of the mHag HA-1 and GvHD has been suggested and methods to facilitate large-scale testing were afterwards developed. Methods We used sequence specific primer (SSP) PCR and direct sequencing to detect HA-1 gene polymorphisms in a sample of 131 unrelated Italian subjects. We then set up a novel melting temperature (Tm) assay that may help identification of HA-1 alleles without oligonucleotide probes. Results We report the frequencies of HA-1 alleles in the Italian population and the presence of an intronic 5 base-pair deletion associated with the immunogeneic allele HA-1H. We also detected novel variable sites with respect to the consensus sequence of HA-1 locus. Even though recombination/gene conversion events are documented, there is considerable linkage disequilibrium in the data. The gametic associations between HA-1R/H alleles and the intronic 5-bp ins/del polymorphism prompted us to try the Tm analysis with SYBR® Green I. We show that the addition of dimethylsulfoxide (DMSO) during the assay yields distinct patterns when amplicons from HA-1H homozygotes, HA-1R homozygotes, and heterozygotes are analysed. Conclusion The possibility to use SYBR® Green I to detect Tm differences between allelic variants is attractive but requires great caution. We succeeded in allele discrimination of the HA-1 locus using a relatively short (101 bp) amplicon, only in the presence of DMSO. We believe that, at least in certain assets, Tm assays may benefit by the addition of DMSO or other agents affecting DNA strand conformation and stability. PMID:16202172

  11. Factors influencing the temporal growth rate of the high order TM{sub 0n} modes in the Ka-band overmoded Cherenkov oscillator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Dapeng, E-mail: vipbenjamin@163.com; Shu, Ting; Ju, Jinchuan

    2015-06-15

    When the wavelength of overmoded Cherenkov oscillator goes into Ka-band, power handling capacity becomes an essential issue. Using the TM{sub 02} mode or higher order TM{sub 0n} modes as the operating mode is a potential solution. This paper is aimed to find some proper parameters to make the temporal growth rate of the TM{sub 02} mode higher in our previously studied Gigawatt (GW)-class Ka band oscillator. An accurate and fast calculation method of the “hot” dispersion equation is derived for rectangular corrugated SWSs, which are widely used in the high frequency Cherenkov devices. Then, factors that affect the temporal growthmore » rate of the high order TM{sub 0n} modes are analyzed, including the depth of corrugation, the radius of drift tube, and the diode voltage. Results show that, when parameters are chosen properly, the temporal growth rate of the TM{sub 02} mode can be as high as 0.3 ns{sup −1}.« less

  12. Positive influence of Tm3+ on effective Er3+: 3 μm emission in fluoride glass under 980 nm excitation

    NASA Astrophysics Data System (ADS)

    Huang, Feifei; Wang, Tao; Guo, Yanyan; Lei, Ruoshan; Xu, Shiqing

    2017-05-01

    Er3+ and Tm3+ singly doped and codoped new fluoride glasses were prepared by traditional melt-quenching method. Efficient 3 μm emission was obtained under 980 nm laser excitation. It is worthy to notice that one of the two ions can be the sensitizer to the other one by depressing the Er3+: 1.5 μm emission through the energy transfer process from Er3+:4I13/2 level to Tm3+:3F4 level. On the basis of measured absorption spectra, the Judd-Ofelt intensity parameters and radiation emission probability were calculated to evaluate the spectroscopic properties. Additionally, the micro-parameters together with the phonon assistance of Er3+:4I13/2 → Tm3+:3F4 and Er3+:4I11/2 → Tm3+:3H5 processes were quantitatively analyzed by using Dexter model. The theoretical micro-parameters results meet well with the experiments which indicates that Er3+/Tm3+ codoped fluoride glass is a potential kind laser glass for 3 μm laser.

  13. Scintillation properties of Tm-doped Lu 3Al 5O 12 single crystals

    NASA Astrophysics Data System (ADS)

    Sugiyama, Makoto; Fujimoto, Yutaka; Yanagida, Takayuki; Totsuka, Daisuke; Yokota, Yuui; Yoshikawa, Akira

    2011-12-01

    Using the micro-pulling-down (μ-PD) method, Tm-doped Lu 3Al 5O 12 (Tm:LuAG) single crystals were grown to examine their scintillation properties. In transmittance spectra, they exhibited about 80% transparency in the wavelengths longer than 320 nm and five absorption lines due to Tm 3+ 4f-4f transitions were observed. 241Am α-ray excited radioluminescence spectra were measured and intense 4f-4f emission peaks were observed with the host emission. When excited by 137Cs γ-Ray to obtain pulse height spectra, Tm 1% doped LuAG showed the highest light yield coupled with a photomultiplier (PMT) or a silicon avalanche photodiode (Si-APD). The light yield was estimated to be 5800 and 7300 photons/MeV for PMT and Si-APD, respectively. Decay time profiles consist of two exponential components and the fast and slow components are considered to be attributed to the host and the combination of the host and Tm 3+ 4f-4f emission, respectively.

  14. Monitoring forest dynamics with multi-scale and time series imagery.

    PubMed

    Huang, Chunbo; Zhou, Zhixiang; Wang, Di; Dian, Yuanyong

    2016-05-01

    To learn the forest dynamics and evaluate the ecosystem services of forest effectively, a timely acquisition of spatial and quantitative information of forestland is very necessary. Here, a new method was proposed for mapping forest cover changes by combining multi-scale satellite remote-sensing imagery with time series data. Using time series Normalized Difference Vegetation Index products derived from the Moderate Resolution Imaging Spectroradiometer images (MODIS-NDVI) and Landsat Thematic Mapper/Enhanced Thematic Mapper Plus (TM/ETM+) images as data source, a hierarchy stepwise analysis from coarse scale to fine scale was developed for detecting the forest change area. At the coarse scale, MODIS-NDVI data with 1-km resolution were used to detect the changes in land cover types and a land cover change map was constructed using NDVI values at vegetation growing seasons. At the fine scale, based on the results at the coarse scale, Landsat TM/ETM+ data with 30-m resolution were used to precisely detect the forest change location and forest change trend by analyzing time series forest vegetation indices (IFZ). The method was tested using the data for Hubei Province, China. The MODIS-NDVI data from 2001 to 2012 were used to detect the land cover changes, and the overall accuracy was 94.02 % at the coarse scale. At the fine scale, the available TM/ETM+ images at vegetation growing seasons between 2001 and 2012 were used to locate and verify forest changes in the Three Gorges Reservoir Area, and the overall accuracy was 94.53 %. The accuracy of the two layer hierarchical monitoring results indicated that the multi-scale monitoring method is feasible and reliable.

  15. Solvent directed morphologies and enhanced luminescent properties of BaWO4:Tm3+,Dy3+ for white light emitting diodes

    NASA Astrophysics Data System (ADS)

    Wu, Hongyue; Yang, Junfeng; Wang, Xiaoxue; Gan, Shucai; Li, Linlin

    2018-05-01

    A series of Tm3+ and Dy3+ codoped BaWO4 phosphors with tunable shapes were controllably synthesized by a facile solvothermal method. The effects of ratio of ethylene glycol (EG) and water on the morphologies of BaWO4 structures are systematically studied. It was discovered that the reason for these morphological changes is based on the reaction speed of the kinetic control, which relates to the strong chelating abilities of ethylene glycol. And when the solvent is pure ethylene glycol, the peanut-like BaWO4:Dy3+ has the strongest emission intensity. Moreover, the emission color of the phosphors varied from blue (0.232, 0.180) to white (0.268, 0.250) by controlling Dy3+ ions content with a fixed Tm3+ concentration. The energy transfer mechanism was investigated in detail. With increasing the doped concentration of Dy3+ ions, the energy transfer efficiency of BaWO4:0.005Tm3+,yDy3+ increased gradually and reached as high as 63% when the Dy3+ doped concentration is 0.03. The critical distance RC calculated by the spectral overlap method is about 19.93 Å, and it is in good agreement with that obtained using the concentration quenching method (19.70 Å), indicating that the electric dipole-dipole interaction is the main energy transfer mechanism for BaWO4:Tm3+,Dy3+ phosphors.

  16. Cryogenic-cooled Tm:SBN tunable laser

    NASA Astrophysics Data System (ADS)

    Švejkar, Richard; Šulc, Jan; Němec, Michal; Jelínková, Helena; Doroshenko, Maxim E.; Papashvili, Alexander G.; Batygov, Sergei H.; Osiko, Vyacheslav V.

    2017-12-01

    In this work the temperature dependence of spectroscopic and laser properties of new ac- tive medium Tm:SBN (Strontium-Barium Niobate, SrxBa1-xNb2O6, x = 0.61). The tested sample of Tm:SBN (2 wt. % of Tm2O3) appropriate for generation of laser radiation at 1.88 μm had plan-parallel polished faces without anti-reflection (thickness 6.65 mm). During spectroscopy and laser experiments the Tm:SBN was at- tached to temperature-controlled copper holder and was placed in a vacuum chamber. The transmission and emission spectra of Tm:SBN and the fluorescence decay time were measured depending on temperature range 80 - 350 K. The fluorescence decay time was measured to be 3.5 ms and 2.8 ms at 80 and 350 K, respectively. Longitudinal excitation of Tm:SBN was carried out by a fibre-coupled laser diode (pulse duration 10 ms, rep- etition rate 10 Hz, pump wavelength 793 nm). The laser resonator was hemispherical, 146 mm long, with flat pumping mirror (HR @1.8 - 2.1 μm) and spherical output coupler (r = 150 mm, R = 97.5 % @1.8 - 2.1 μm). The Tm:SBN laser properties were investigated at temperature range 80 - 300 K. The highest slope efficiency with respect to absorbed pumped power was 3 % at 80 K. The maximum output peak amplitude power was 0.12 W at 80 K, i.e. 3.2 times higher than it was measured at 200 K. Tunability of laser wavelength at 80 K in the range of 1827 - 1962 nm was obtained by using SiO2 birefringent filter. At 300 K, wavelength tunability reached 1859 - 1970 nm. Thus, the new Tm:SBN crystal can be an useful laser material in the region of 2 μm.

  17. Dimensional stability of two impression materials after a 6-month storage period.

    PubMed

    Martins, Francisco; Branco, Patrícia; Reis, José; Barbero Navarro, Ignacio; Maurício, Paulo

    2017-01-01

    Objective: Oral rehabilitation success is enhanced by an accurate and reproducible final impression. The purpose of this study is to evaluate the dimensional changes of a polyether and addition silicone subjected to disinfection and/or sterilization after a long storage period. Material and methods: Ninety samples were obtained from polyether Impregum TM Penta TM (3M ESPE TM , Seefeld, Germany) and 90 of addition silicone Imprint TM 4 Penta TM Putty (3M ESPE TM , Seefeld, Germany) according to ISO 4823:2000. The samples of each material were split to form three groups with 30 samples each: a control group, a hypochlorite group (disinfection) and an autoclave group (sterilization). Samples were stored in the Portuguese Institute for Quality for six months at 23 °C. Samples were measured by laser interferometry, according to the Michelson technique before calculating dimensional stability according ISO 4823:2000. A statistical analysis via a three-way mixed ANOVA was performed. Results: Significant shrinkage of Impregum TM Penta TM was 0.77 ± 0.17% in the control group, 0.42 ± 0.19% in the hypochlorite group and 0.52 ± 0.28% in the autoclave group. For Imprint TM 4 Penta TM Putty, the control group had a shrinkage of 0.42 ± 0.12%, the hypochlorite group 0.36 ± 0.09% and the autoclave group 0.59 ± 0.13%. Conclusions: The long-term storage of samples subjected to disinfection with 5.25% hypochlorite or autoclave sterilization can be used in a clinical setting as the dimensional changes are below the maximum permitted by the ISO 4823:2000, since there are no clinically significant changes in the dimension of the samples during the storage period.

  18. 'They don't ask me so I don't tell them': patient-clinician communication about traditional, complementary, and alternative medicine.

    PubMed

    Shelley, Brian M; Sussman, Andrew L; Williams, Robert L; Segal, Alissa R; Crabtree, Benjamin F

    2009-01-01

    Although high rates of traditional medicine and complementary and alternative medicine (TM/CAM) use have been well documented, there has been less attention to the factors influencing communication between patients and their primary care clinicians about TM/CAM. Such communication can be important in anticipating possible drug-herb interactions and in assuring agreement about therapeutic plans. We used sequential, multistage, qualitative methods, including focus groups, in-depth interviews, and a video vignette, to explore communication about TM/CAM between patients and their primary care clinicians. The study was conducted in RIOS Net (Research Involved in Outpatient Settings Network), a Southwestern US practice-based research network, situated largely in Hispanic and American Indian communities where TM/CAM is an important part of self-care. One hundred fourteen patients, 41 clinic staff members, and 19 primary care clinicians in 8 clinic sites participated. The degree and nature of TM/ CAM communication is based on certain conditions in the clinical encounter. We categorized these findings into 3 themes: acceptance/nonjudgment, initiation of communication, and safety/efficacy. Perceived clinician receptivity to and initiation of discussion about TM/CAM strongly influenced patients' decisions to communicate; perceived clinician expertise in TM/CAM was less important. Clinicians' comfort with patients' self-care approaches and their level of concern about lack of scientific evidence of effectiveness and safety of TM/CAM influenced their communication about TM/CAM with patients. Specific communication barriers limit patient-clinician communication about TM/CAM. Clinicians who wish to communicate more effectively with their patients about these topics and better integrate the types of care their patients use can change the communication dynamic with simple strategies designed to overcome these barriers.

  19. Benefits and limitations of drug studies in temperament research: biochemical responses as indicators of temperament.

    PubMed

    Netter, Petra

    2018-04-19

    This paper presents a discussion of principles and problems of neurotransmitter challenge tests using examples of experiments, most of which were performed in the author's laboratory. Drugs targeting synthesis, release, receptors or reuptake of dopamine, serotonin and noradrenergic transmitter (TM) systems were used for characterizing or discriminating certain temperament or personality traits and their sub-factors. Any personality or temperament trait is characterized by multiple TM responses, thus constellations of hormone responses to drugs acting on different TM systems or on different sources of TM activity were investigated within individuals in crossover designs. The major conclusions are: (i) intra-individual patterns of hormone responses to different TM-related drugs, or to agonists and antagonists, can help to discriminate subtypes of temperament dimensions, and (ii) the latency and shape of response curves may help specify processes of biological responses related to psychological dimensions and reveal common TM sensitivities in clusters of traits. TM sensitivity, defined by hormone responses, does not always correspond to accompanying behavioural indicators, but may provide more specific information on underlying mechanisms. Additional consideration of drug doses and experimental induction of stressors may serve to identify temperament-related susceptibilities to certain drugs. Limitations of the challenge approach and recommendations for future research are discussed.This article is part of the theme issue 'Diverse perspectives on diversity: multi-disciplinary approaches to taxonomies of individual differences'. © 2018 The Author(s).

  20. Synthesis and structural characterization of transition metal doped MgO: Mg0.95Mn0.01TM0.04O (TM = Co, Ni, Cu)

    NASA Astrophysics Data System (ADS)

    Islam, Ishtihadah; Khandy, Shakeel Ahmad; Hafiz, Aurangzeb Khurram

    2018-05-01

    In the present work, preparation and characterization of transition metal doped MgO: Zn0.94Mn0.01TM0.05O (TM = Co, Ni and Cu) nano-particles have been reported. Transition metal doped samples of MgO were synthesized by Sol gel auto combustion method. Structural characterisation from XRD and SEM show the formation of single-phase primary particles, nearly of spherical shaped nano-crystallites. The crystallite size was found to be 78.2, 67.02, 78.11 and 64 nm for pure, Co, Cu and Ni doped MgMnO nano-particles, respectively. Hence, the average crystallite size increases monotonously from Co to Cu doping.

  1. Pattern of traditional medicine use by adult Saudi patients with neurological disorders.

    PubMed

    Mohammad, Yousef; Al-Ahmari, Ahmed; Al-Dashash, Fahad; Al-Hussain, Fawaz; Al-Masnour, Firas; Masoud, Abdullah; Jradi, Hoda

    2015-04-01

    Traditional medicine (TM) has been established as a two-edged sword. On one edge numerous forms of TM have been proven safe and effective, while on the other edge various modes of TM have been shown to be futile and potentially dangerous. Resorting to TM, especially for chronic diseases, is common world-wide and includes Saudi Arabia. Most neurological diseases are chronic. No data is available on the utilization of TM among patients with neurological disorders. We conducted this study to assess for the prevalence, pattern, perception and triggers for TM use by the adult Saudi patients with neurological disorders. A survey written in Arabic and comprised of 15 questions was used to collect data on the practice of TM among the neurology patients of King Saud University Ambulatory Clinic. The questions in the survey pertain mainly to the frequency of TM practice, its form and the patient's opinion of this practice. The data was collected through a face to face interview by three medical students who were instructed on the survey questions prior to the launch of the study. 292 patients completed the survey (35.9% males and 64.0% females). 67% (n = 196) of the sample used TM. Cupping or what is commonly known as "hojamah" was the most prevalent method (45.4%) followed by herbs, skin cauterization and the Reciting of the Holy Quran (42.3%, 33.7% and 20.4% respectively). The prevalence of TM use did not differ across gender (chi-sq = 2.02; p-value = 0.15), level of education (chi-sq = 4.02; p-value = 0.40), health status (chi-sq = 2.29; p-value = 0.68), age groups (chi-sq = 5.12; p-value = 0.16), or perception toward TM (chi-sq = 2.67; p-value = 0.26) in this population. The practice of TM is common among the neurology patients of Saudi Arabia. Cupping, herbs, and skin cauterization, which can be harmful when wrongly employed, are frequently utilized in this patient population. Measures and policies to endorse the appropriate use of TM by Saudi society must be implemented promptly.

  2. Full-field transient vibrometry of the human tympanic membrane by local phase correlation and high-speed holography

    NASA Astrophysics Data System (ADS)

    Dobrev, Ivo; Furlong, Cosme; Cheng, Jeffrey T.; Rosowski, John J.

    2014-09-01

    Understanding the human hearing process would be helped by quantification of the transient mechanical response of the human ear, including the human tympanic membrane (TM or eardrum). We propose a new hybrid high-speed holographic system (HHS) for acquisition and quantification of the full-field nanometer transient (i.e., >10 kHz) displacement of the human TM. We have optimized and implemented a 2+1 frame local correlation (LC) based phase sampling method in combination with a high-speed (i.e., >40 K fps) camera acquisition system. To our knowledge, there is currently no existing system that provides such capabilities for the study of the human TM. The LC sampling method has a displacement difference of <11 nm relative to measurements obtained by a four-phase step algorithm. Comparisons between our high-speed acquisition system and a laser Doppler vibrometer indicate differences of <10 μs. The high temporal (i.e., >40 kHz) and spatial (i.e., >100 k data points) resolution of our HHS enables parallel measurements of all points on the surface of the TM, which allows quantification of spatially dependent motion parameters, such as modal frequencies and acoustic delays. Such capabilities could allow inferring local material properties across the surface of the TM.

  3. 78 FR 24714 - Notice of Funds Availability Inviting Applications for the Federal-State Marketing Improvement...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-26

    ... channels. Assist in the development of more efficient marketing methods, practices, and facilities to bring... DEPARTMENT OF AGRICULTURE Agricultural Marketing Service [Doc. No. AMS-TM-12-0053; TM-12-03] Notice of Funds Availability Inviting Applications for the Federal-State Marketing Improvement Program...

  4. Accuracy of prospective memory tests in mild Alzheimer's disease.

    PubMed

    Martins, Sergilaine Pereira; Damasceno, Benito Pereira

    2012-01-01

    To verify the accuracy of prospective memory (ProM) tests in Alzheimer's disease (AD). Twenty mild AD patients (CDR 1), and 20 controls underwent Digit Span (DS), Trail Making (TM) A and B, visual perception, Rey Auditory-Verbal Learning tests, and Cornell Scale for Depression. AD diagnosis was based on DSM-IV and NINCDS-ADRDA criteria. ProM was assessed with the appointment and belonging subtests of Rivermead Behavioral Memory Test (RBMT); and with two new tests (the clock and animal tests). AD patients had a worse performance than controls on the majority of tests, except DS forward and TM-A. There was no correlation between RBMT and the new ProM tests. As for accuracy, the only significant difference concerned the higher sensitivity of our animal test versus the RBMT belonging test. The clock and the animal tests showed similar specificity, but higher sensitivity than the RBMT subtests.

  5. Spectral signature of alpine snow cover from the Landsat Thematic Mapper

    NASA Technical Reports Server (NTRS)

    Dozier, Jeff

    1989-01-01

    In rugged terrain, snow in the shadows can appear darker than soil or vegetation in the sunlight, making it difficult to interpret satellite data images of rugged terrains. This paper discusses methods for using Thematic Mapper (TM) and SPOT data for automatic analyses of alpine snow cover. Typical spectral signatures of the Landsat TM are analyzed for a range of snow types, atmospheric profiles, and topographic illumination conditions. A number of TM images of Sierra Nevada are analyzed to distinguish several classes of snow from other surface covers.

  6. Plastic Muscles TM as lightweight, low voltage actuators and sensors

    NASA Astrophysics Data System (ADS)

    Bennett, Matthew; Leo, Donald; Duncan, Andrew

    2008-03-01

    Using proprietary technology, Discover Technologies has developed ionomeric polymer transducers that are capable of long-term operation in air. These "Plastic Muscle TM" transducers are useful as soft distributed actuators and sensors and have a wide range of applications in the aerospace, robotics, automotive, electronics, and biomedical industries. Discover Technologies is developing novel fabrication methods that allow the Plastic Muscles TM to be manufactured on a commercial scale. The Plastic Muscle TM transducers are capable of generating more than 0.5% bending strain at a peak strain rate of over 0.1 %/s with a 3 V input. Because the Plastic Muscles TM use an ionic liquid as a replacement solvent for water, they are able to operate in air for long periods of time. Also, the Plastic Muscles TM do not exhibit the characteristic "back relaxation" phenomenon that is common in water-swollen devices. The elastic modulus of the Plastic Muscle TM transducers is estimated to be 200 MPa and the maximum generated stress is estimated to be 1 MPa. Based on these values, the maximum blocked force at the tip of a 6 mm wide, 35 mm long actuator is estimated to be 19 mN. Modeling of the step response with an exponential series reveals nonlinearity in the transducers' behavior.

  7. Additives for Water Mist Fire Suppression Systems: A Review

    DTIC Science & Technology

    2012-11-01

    TM 2012-236; R & D pour la défense Canada – Atlantique; novembre 2012. Introduction : On utilisait les halons comme agents extincteurs dans les... 13 Table 11: Results of fire extinguishment tests on kerosene or heptanes pan fires using water mist and water mist with 2 vol...Forafac® WM. ....................................................... 13 x DRDC Atlantic TM 2012-236 This page intentionally left

  8. Excite Kids about Engineering: Design Squad[TM] and Engineer Your Life[TM] Resources Make It Easy

    ERIC Educational Resources Information Center

    Cheng, Jack

    2008-01-01

    The author discusses "Design Squad", a television program designed to introduce students to the engineering process. Each episode tells the story of how two teams tackled a particular challenge. A graphic announces each stage (e.g., brainstorm, design, build, test, and redesign) as the teams construct their solutions. These graphics make visual…

  9. Lipid Neuroprotectants and Traumatic Glaucomatous Neurodegeneration

    DTIC Science & Technology

    2016-05-01

    alter elastic TM, modulus and binding and functional assays with potential protein targets. Endogenous lipids, Aqueous humor, Trabecular meshwork...Intraocular pressure, sphingolipids, primary cell culture, elastic modulus, protein targets. Major goal 1. Test the hypothesis that selected lipids...glaucomatous TM with and without these lipids and atomic force microscope (AFM). Further elastic modulus using high flow and low flow areas of glaucomatous

  10. A Pilot Randomized Controlled Trial of DIR/Floortime[TM] Parent Training Intervention for Pre-School Children with Autistic Spectrum Disorders

    ERIC Educational Resources Information Center

    Pajareya, Kingkaew; Nopmaneejumruslers, Kaewta

    2011-01-01

    This pilot study was designed to test the efficacy of adding home-based Developmental, Individual-Difference, Relationship-Based (DIR)/Floortime[TM] intervention to the routine care of preschool children with autistic spectrum disorder. Measures of functional emotional development and symptom severity were taken. It was found that after the…

  11. Data compression experiments with LANDSAT thematic mapper and Nimbus-7 coastal zone color scanner data

    NASA Technical Reports Server (NTRS)

    Tilton, James C.; Ramapriyan, H. K.

    1989-01-01

    A case study is presented where an image segmentation based compression technique is applied to LANDSAT Thematic Mapper (TM) and Nimbus-7 Coastal Zone Color Scanner (CZCS) data. The compression technique, called Spatially Constrained Clustering (SCC), can be regarded as an adaptive vector quantization approach. The SCC can be applied to either single or multiple spectral bands of image data. The segmented image resulting from SCC is encoded in small rectangular blocks, with the codebook varying from block to block. Lossless compression potential (LDP) of sample TM and CZCS images are evaluated. For the TM test image, the LCP is 2.79. For the CZCS test image the LCP is 1.89, even though when only a cloud-free section of the image is considered the LCP increases to 3.48. Examples of compressed images are shown at several compression ratios ranging from 4 to 15. In the case of TM data, the compressed data are classified using the Bayes' classifier. The results show an improvement in the similarity between the classification results and ground truth when compressed data are used, thus showing that compression is, in fact, a useful first step in the analysis.

  12. Evaluation of Fieldbus and OPC for Advanced Life Support

    NASA Technical Reports Server (NTRS)

    Boulanger, Richard P.; Cardinale, Paul; Bradley, Matthew; Luna, Bernadette (Technical Monitor)

    2000-01-01

    FOUNDATION(Tm) Fieldbus and OP(TM) (OLE(TM)for Process Control) technologies were integrated into an existing control system for a crop growth chamber at NASA Ames Research Center. FOUNDATION(TM) Fieldbus is a digital, bi-directional, multi-drop, serial communications network which functions essentially as a LAN for sensors. FOUNDATION(TM) Fieldbus is heterarchical, with publishers and subscribers of data performing complex control functions at low levels without centralized control and its associated overhead. OPC(TM) is a set of interfaces which replace proprietary drivers with a transparent means of exchanging data between the fieldbus and applications. The objectives were: (1) to integrate FOUNDATION(TM) Fieldbus into existing ALS hardware and determine its overall effectiveness and reliability and, (2) to quantify any savings produced by using fieldbus and OPC technologies. We encountered several problems with the FOUNDATION(TM) Fieldbus hardware chosen. Our hardware exposed 100 data for each channel of the fieldbus. The fieldbus configurator software used to program the fieldbus was simply not adequate. The fieldbus was also not inherently reliable. It lost its settings twice during our tests for unknown reasons. OPC also had issues. It did not function at all as supplied, requiring substitution of some of its components with those from other vendors. It would stop working after a fixed period of time. Certain database calls eventually lock the machine. Overall, we would not recommend FOUNDATION(TM) Fieldbus: it was too difficult to implement with little overall added value. It also seems unlikely that FOUNDATION(TM) Fieldbus will gain sufficient penetration into the laboratory instrument market to ever be cost effective for the ALS community. OPC had good reliability and performance once a stable installation was achieved. It allowed a rapid change to an alternative software strategy when our first strategy failed. It is a cost effective solution to distributed control systems development.

  13. Myocardial blood flow estimates from dynamic contrast-enhanced magnetic resonance imaging: three quantitative methods

    NASA Astrophysics Data System (ADS)

    Borrazzo, Cristian; Galea, Nicola; Pacilio, Massimiliano; Altabella, Luisa; Preziosi, Enrico; Carnì, Marco; Ciolina, Federica; Vullo, Francesco; Francone, Marco; Catalano, Carlo; Carbone, Iacopo

    2018-02-01

    Dynamic contrast-enhanced cardiovascular magnetic resonance imaging can be used to quantitatively assess the myocardial blood flow (MBF), recovering the tissue impulse response function for the transit of a gadolinium bolus through the myocardium. Several deconvolution techniques are available, using various models for the impulse response. The method of choice may influence the results, producing differences that have not been deeply investigated yet. Three methods for quantifying myocardial perfusion have been compared: Fermi function modelling (FFM), the Tofts model (TM) and the gamma function model (GF), with the latter traditionally used in brain perfusion MRI. Thirty human subjects were studied at rest as well as under cold pressor test stress (submerging hands in ice-cold water), and a single bolus of gadolinium weighing 0.1  ±  0.05 mmol kg-1 was injected. Perfusion estimate differences between the methods were analysed by paired comparisons with Student’s t-test, linear regression analysis, and Bland-Altman plots, as well as also using the two-way ANOVA, considering the MBF values of all patients grouped according to two categories: calculation method and rest/stress conditions. Perfusion estimates obtained by various methods in both rest and stress conditions were not significantly different, and were in good agreement with the literature. The results obtained during the first-pass transit time (20 s) yielded p-values in the range 0.20-0.28 for Student’s t-test, linear regression analysis slopes between 0.98-1.03, and R values between 0.92-1.01. From the Bland-Altman plots, the paired comparisons yielded a bias (and a 95% CI)—expressed as ml/min/g—for FFM versus TM, -0.01 (-0.20, 0.17) or 0.02 (-0.49, 0.52) at rest or under stress respectively, for FFM versus GF, -0.05 (-0.29, 0.20) or  -0.07 (-0.55, 0.41) at rest or under stress, and for TM versus GF, -0.03 (-0.30, 0.24) or  -0.09 (-0.43, 0.26) at rest or under stress. With the two-way ANOVA, the results were p  =  0.20 for the method effect (not significant), p  <  0.0001 for the rest/stress condition effect (highly significant, as expected), whereas no interaction resulted between the rest/stress condition and method (p  =  0.70, not significant). Considering a wider time-frame (60 s), the estimates for both rest and stress conditions were 25%-30% higher (p in the range 0.016-0.025) than those obtained in the 20 s time-frame. MBF estimates obtained by various methods under rest/stress conditions were not significantly different in the first-pass transit time, encouraging quantitative perfusion estimates in DCE-CMRI with the used methods.

  14. Two-micrometer thulium laser resection of the prostate-tangerine technique in benign prostatic hyperplasia patients with previously negative transrectal prostate biopsy.

    PubMed

    Zhuo, Jian; Wei, Hai-Bin; Zhang, Fei; Liu, Hai-Tao; Zhao, Fu-Jun; Han, Bang-Min; Sun, Xiao-Wen; Xia, Shu-Jie

    2017-01-01

    The 2-μm thulium laser resection of the prostate-tangerine technique (TmLRP-TT) has been introduced as a minimally invasive treatment for benign prostatic hyperplasia (BPH). This study was undertaken to assess the clinical efficacy and safety of TmLRP-TT for the treatment of BPH patients with previously negative transrectal prostate biopsy. A prospective analysis of 51 patients with previously negative transrectal prostate biopsy who underwent surgical treatment using TmLRP-TT was performed from December 2011 to December 2013. Preoperative status, surgical details, and perioperative complications were recorded. The follow-up outcome was evaluated with subjective and objective tests at 1 and 6 months. TmLRP-TT was successfully completed in all patients. Mean prostate volume, operative duration, and catheterization time were 93.3 ± 37.9 ml, 69.5 ± 39.5 min, and 6.5 ± 1.3 days, respectively. The mean International Prostate Symptom Score, quality of life score, maximum urinary flow rate, and post-void residual urine volume changed notably at 6-month follow-up (22.5 ± 6.9 vs 6.1 ± 3.2, 4.8 ± 1.3 vs 1.1 ± 0.9, 7.3 ± 4.5 vs 18.9 ± 7.1 ml s-1 , and 148.7 ± 168.7 vs 28.4 ± 17.9 ml). Two (3.9%) patients required blood transfusion perioperatively, while 3 (5.9%) patients experienced transient hematuria postoperatively, and 2 (3.9%) patients received 3 days recatheterization due to clot retention. TmLRP-TT is a safe and effective minimally invasive technique for patients with previously negative transrectal prostate biopsy during the 6-month follow-up. This promising technology may be a feasible surgical method for previously negative transrectal prostate biopsy in the future.

  15. Two-micrometer thulium laser resection of the prostate-tangerine technique in benign prostatic hyperplasia patients with previously negative transrectal prostate biopsy

    PubMed Central

    Zhuo, Jian; Wei, Hai-Bin; Zhang, Fei; Liu, Hai-Tao; Zhao, Fu-Jun; Han, Bang-Min; Sun, Xiao-Wen; Jun-Lu; Xia, Shu-Jie

    2017-01-01

    The 2-μm thulium laser resection of the prostate-tangerine technique (TmLRP-TT) has been introduced as a minimally invasive treatment for benign prostatic hyperplasia (BPH). This study was undertaken to assess the clinical efficacy and safety of TmLRP-TT for the treatment of BPH patients with previously negative transrectal prostate biopsy. A prospective analysis of 51 patients with previously negative transrectal prostate biopsy who underwent surgical treatment using TmLRP-TT was performed from December 2011 to December 2013. Preoperative status, surgical details, and perioperative complications were recorded. The follow-up outcome was evaluated with subjective and objective tests at 1 and 6 months. TmLRP-TT was successfully completed in all patients. Mean prostate volume, operative duration, and catheterization time were 93.3 ± 37.9 ml, 69.5 ± 39.5 min, and 6.5 ± 1.3 days, respectively. The mean International Prostate Symptom Score, quality of life score, maximum urinary flow rate, and post-void residual urine volume changed notably at 6-month follow-up (22.5 ± 6.9 vs 6.1 ± 3.2, 4.8 ± 1.3 vs 1.1 ± 0.9, 7.3 ± 4.5 vs 18.9 ± 7.1 ml s−1, and 148.7 ± 168.7 vs 28.4 ± 17.9 ml). Two (3.9%) patients required blood transfusion perioperatively, while 3 (5.9%) patients experienced transient hematuria postoperatively, and 2 (3.9%) patients received 3 days recatheterization due to clot retention. TmLRP-TT is a safe and effective minimally invasive technique for patients with previously negative transrectal prostate biopsy during the 6-month follow-up. This promising technology may be a feasible surgical method for previously negative transrectal prostate biopsy in the future. PMID:26732107

  16. Molecular Weight Cut-Off and Structural Analysis of Vacuum-Assisted Titania Membranes for Water Processing

    PubMed Central

    Abd Jalil, Siti Nurehan; Wang, David K.; Yacou, Christelle; Motuzas, Julius; Smart, Simon; Diniz da Costa, João C.

    2016-01-01

    This work investigates the structural formation and analyses of titania membranes (TM) prepared using different vacuum exposure times for molecular weight (MW) cut-off performance and oil/water separation. Titania membranes were synthesized via a sol-gel method and coated on macroporous alumina tubes followed by exposure to a vacuum between 30 and 1200 s and then calcined at 400 °C. X-ray diffraction and nitrogen adsorption analyses showed that the crystallite size and particle size of titania increased as a function of vacuum time. All the TM membranes were mesoporous with an average pore diameter of ~3.6 nm with an anatase crystal morphology. Water, glucose, sucrose, and polyvinylpyrrolidone with 40 and 360 kDa (PVP-40 kDa and PVP-360 kDa) were used as feed solutions for MW cut-off and hexadecane solution for oil filtration investigation. The TM membranes were not able to separate glucose and sucrose, thus indicating the membrane pore sizes are larger than the kinetic diameter of sucrose of 0.9 nm, irrespective of vacuum exposure time. They also showed only moderate rejection (20%) of the smaller PVP-40 kDa, however, all the membranes were able to obtain an excellent rejection of near 100% for the larger PVP-360 kDa molecule. Furthermore, the TM membranes were tested for the separation of oil emulsions with a high concentration of oil (3000 ppm), reaching high oil rejections of more than 90% of oil. In general, the water fluxes increased with the vacuum exposure time indicating a pore structural tailoring effect. It is therefore proposed that a mechanism of pore size tailoring was formed by an interconnected network of Ti–O–Ti nanoparticles with inter-particle voids, which increased as TiO2 nanoparticle size increased as a function of vacuum exposure time, and thus reduced the water transport resistance through the TM membranes. PMID:28774057

  17. The fragmented nature of tundra landscape

    NASA Astrophysics Data System (ADS)

    Virtanen, Tarmo; Ek, Malin

    2014-04-01

    The vegetation and land cover structure of tundra areas is fragmented when compared to other biomes. Thus, satellite images of high resolution are required for producing land cover classifications, in order to reveal the actual distribution of land cover types across these large and remote areas. We produced and compared different land cover classifications using three satellite images (QuickBird, Aster and Landsat TM5) with different pixel sizes (2.4 m, 15 m and 30 m pixel size, respectively). The study area, in north-eastern European Russia, was visited in July 2007 to obtain ground reference data. The QuickBird image was classified using supervised segmentation techniques, while the Aster and Landsat TM5 images were classified using a pixel-based supervised classification method. The QuickBird classification showed the highest accuracy when tested against field data, while the Aster image was generally more problematic to classify than the Landsat TM5 image. Use of smaller pixel sized images distinguished much greater levels of landscape fragmentation. The overall mean patch sizes in the QuickBird, Aster, and Landsat TM5-classifications were 871 m2, 2141 m2 and 7433 m2, respectively. In the QuickBird classification, the mean patch size of all the tundra and peatland vegetation classes was smaller than one pixel of the Landsat TM5 image. Water bodies and fens in particular occur in the landscape in small or elongated patches, and thus cannot be realistically classified from larger pixel sized images. Land cover patterns vary considerably at such a fine-scale, so that a lot of information is lost if only medium resolution satellite images are used. It is crucial to know the amount and spatial distribution of different vegetation types in arctic landscapes, as carbon dynamics and other climate related physical, geological and biological processes are known to vary greatly between vegetation types.

  18. The Contribution of the Vaccine Adverse Event Text Mining System to the Classification of Possible Guillain-Barré Syndrome Reports

    PubMed Central

    Botsis, T.; Woo, E. J.; Ball, R.

    2013-01-01

    Background We previously demonstrated that a general purpose text mining system, the Vaccine adverse event Text Mining (VaeTM) system, could be used to automatically classify reports of an-aphylaxis for post-marketing safety surveillance of vaccines. Objective To evaluate the ability of VaeTM to classify reports to the Vaccine Adverse Event Reporting System (VAERS) of possible Guillain-Barré Syndrome (GBS). Methods We used VaeTM to extract the key diagnostic features from the text of reports in VAERS. Then, we applied the Brighton Collaboration (BC) case definition for GBS, and an information retrieval strategy (i.e. the vector space model) to quantify the specific information that is included in the key features extracted by VaeTM and compared it with the encoded information that is already stored in VAERS as Medical Dictionary for Regulatory Activities (MedDRA) Preferred Terms (PTs). We also evaluated the contribution of the primary (diagnosis and cause of death) and secondary (second level diagnosis and symptoms) diagnostic VaeTM-based features to the total VaeTM-based information. Results MedDRA captured more information and better supported the classification of reports for GBS than VaeTM (AUC: 0.904 vs. 0.777); the lower performance of VaeTM is likely due to the lack of extraction by VaeTM of specific laboratory results that are included in the BC criteria for GBS. On the other hand, the VaeTM-based classification exhibited greater specificity than the MedDRA-based approach (94.96% vs. 87.65%). Most of the VaeTM-based information was contained in the secondary diagnostic features. Conclusion For GBS, clinical signs and symptoms alone are not sufficient to match MedDRA coding for purposes of case classification, but are preferred if specificity is the priority. PMID:23650490

  19. Emerging Role of Endothelial and Inflammatory Markers in Preeclampsia

    PubMed Central

    Swellam, Menha; Samy, Nervana; Abdl Wahab, Susan; Ibrahim, Mohamed Saeed

    2009-01-01

    Objectives: Endothelial disturbance and excess inflammatory response are pathogenic mechanisms in pre-eclampsia (PE). Authors determine the clinical diagnostic role for thrombomodulin (TM), plasminogen activator inhibitor-1 (PAI-1) as endothelial markers and C-reactive protein (CRP), and interlukin-6 (IL-6) as inflammatory markers when tested independently or in combinations. Materials and methods: We conducted a retrospective study in a cohort of 185 women grouped as 80 women with PE, 55 normotensive pregnant and 50 healthy non-pregnant. Plasma levels of TM, PAI-1, CRP and IL-6 were examined using enzyme linked immunosorbent assays. Results: Median levels and the positivity rates for the investigated markers were higher in PE as compared to the other groups (P < 0.0001). Using linear regression analysis, the investigated markers were significantly correlated regarding healthy nonpregnant vs PE or normotensive pregnant vs PE. The sensitivity of PAI-1 was the highest (98%) among the tested biomarkers. Combination between the investigated markers revealed absolute sensitivity (100%) and reliable specificity especially when PAI-1 was combined with CRP at 83% specificity. Conclusions: Investigated endothelial and inflammatory markers revealed sensitive diagnostic test for PE. However, coupled combination between PAI-1 with CRP showed superior both sensitivity and specificity which represent a promising new approach for detection of PE. PMID:19597295

  20. Improving Blood Monitoring of Enzymes as Biomarkers of Risk from Anticholinergic Pesticides and Chemical Warfare Agents

    DTIC Science & Technology

    2007-10-01

    agent exposure --monitoring blood cholinesterase activity with the Test-mateTM OP Kit. In Technical Bulletin: Assay Techniques for Detection of Exposure ...at CHPPM and by the Ellman method at UC Davis. Second, DFP-treated whole blood was used to mimic OP exposure . RBC AChE activity was measured using... cholinesterase activity in mammalian blood and tissue. Bulletin of Environmental Contamination and Toxicology 77(6):785- 792 Arrieta DE, McCurdy

  1. Evaluation of Unexploded Ordnance (UXO) Detection Technology at the Standardized UXO Test Sites Aberdeen and Yuma Proving Grounds

    DTIC Science & Technology

    2007-11-01

    TTF Open Field (169) EM EM61MKII cart May. 2006 USGS Blind Grid (805) EM All TEM towed May. 2006 USGS Blind Grid (806) MAG TMGS towed 2.3-1 2.3...0.98 at YPG with a TMGS towed and an TM-4 sling system. f. The only ground penetrating radar system analyzed was demonstrated at the APG blind...MAG858/Cart(312) SCH/Hand(238) SCH/Hand(606) STOLS/Towed(293M) TM4/Sling(362) TM4/Sling(431) TMGS /Towed(806) EM61G822A/Cart(383D) STOLS/Towed(293D

  2. Correspondence: In support of the IES method of evaluating light source colour rendition

    DOE PAGES

    Ashdown, I.; Aviles, G.; Bennett, L.; ...

    2015-11-20

    In this editorial, written as an open letter to the lighting community, we stand in support of widespread adoption of TM-30-15: The IES Method of Evaluating Light Source Color Rendition. We introduce important considerations related to light source color rendition, define the need for a new method of evaluation, provide a high-level overview of the IES method, discuss some of the practical considerations related to the development of the IES method and the consensus process, and conclude by inviting you to join us in support of the new measures and graphics described in TM-30-15.

  3. Lattice sites of ion-implanted Mn, Fe and Ni in 6H-SiC

    NASA Astrophysics Data System (ADS)

    Costa, A. R. G.; Wahl, U.; Correia, J. G.; David-Bosne, E.; Amorim, L. M.; Augustyns, V.; Silva, D. J.; da Silva, M. R.; Pereira, L. M. C.

    2018-01-01

    Using radioactive isotopes produced at the CERN-ISOLDE facility, the lattice location of the implanted transition metal (TM) ions 56Mn, 59Fe and 65Ni in n-type single-crystalline hexagonal 6H-SiC was studied by means of the emission channeling technique. TM probes on carbon coordinated tetrahedral interstitial sites (T C) and on substitutional silicon sites (S Si,h+k ) were identified. We tested for but found no indication that the TM distribution on S Si sites deviates from the statistical mixture of 1/3 hexagonal and 2/3 cubic sites present in the 6H crystal. The TM atoms partially disappear from T C positions during annealing at temperatures between 500 °C and 700 °C which is accompanied by an increase on S Si and random sites. From the temperature associated with these site changes, interstitial migration energies of 1.7-2.7 eV for Mn and Ni, and 2.3-3.2 eV for Fe were estimated. TM lattice locations are compared to previous results obtained in 3C-SiC using the same technique.

  4. Randomized noninferiority clinical trial evaluating 3 commercial dry cow mastitis preparations: II. Cow health and performance in early lactation.

    PubMed

    Arruda, A G; Godden, S; Rapnicki, P; Gorden, P; Timms, L; Aly, S S; Lehenbauer, T W; Champagne, J

    2013-10-01

    The objective of this randomized noninferiority clinical trial was to compare the effect of treatment with 3 different dry cow therapy formulations at dry-off on cow-level health and production parameters in the first 100 d in milk (DIM) in the subsequent lactation, including 305-d mature-equivalent (305 ME) milk production, linear score (LS), risk for the cow experiencing a clinical mastitis event, risk for culling or death, and risk for pregnancy by 100 DIM. A total of 1,091 cows from 6 commercial dairy herds in 4 states (California, Iowa, Minnesota, and Wisconsin) were randomly assigned at dry-off to receive treatment with 1 of 3 commercial products: Quartermaster (QT; Zoetis Animal Health, Madison, NJ), Spectramast DC (SP; Zoetis Animal Health) or ToMorrow Dry Cow (TM; Boehringer Ingelheim Vetmedica Inc., St Joseph, MO). All clinical mastitis, pregnancy, culling, and death events occurring in the first 100 DIM were recorded by farm staff using an on-farm electronic record-keeping system. Dairy Herd Improvement Association test-day records of milk production and milk component testing were retrieved electronically. Mixed linear regression analysis was used to describe the effect of treatment on 305ME milk production and LS recorded on the last Dairy Herd Improvement Association test day before 100 DIM. Cox proportional hazards regression analysis was used to describe the effect of treatment on risk for experiencing a case of clinical mastitis, risk for leaving the herd, and risk for pregnancy between calving and 100 DIM. Results showed no effect of treatment on adjusted mean 305 ME milk production (QT=11,759 kg, SP=11,574 kg, and TM=11,761 kg) or adjusted mean LS (QT=1.8, SP=1.9, and TM=1.6) on the last test day before 100 DIM. Similarly, no effect of treatment was observed on risk for a clinical mastitis event (QT=14.8%, SP=12.7%, and TM=15.0%), risk for leaving the herd (QT=7.5%, SP=9.2%, and TM=10.3%), or risk for pregnancy (QT=31.5%, SP=26.1%, and TM=26.9%) between calving and 100 DIM. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  5. Forward and backward tone mapping of high dynamic range images based on subband architecture

    NASA Astrophysics Data System (ADS)

    Bouzidi, Ines; Ouled Zaid, Azza

    2015-01-01

    This paper presents a novel High Dynamic Range (HDR) tone mapping (TM) system based on sub-band architecture. Standard wavelet filters of Daubechies, Symlets, Coiflets and Biorthogonal were used to estimate the proposed system performance in terms of Low Dynamic Range (LDR) image quality and reconstructed HDR image fidelity. During TM stage, the HDR image is firstly decomposed in sub-bands using symmetrical analysis-synthesis filter bank. The transform coefficients are then rescaled using a predefined gain map. The inverse Tone Mapping (iTM) stage is straightforward. Indeed, the LDR image passes through the same sub-band architecture. But, instead of reducing the dynamic range, the LDR content is boosted to an HDR representation. Moreover, in our TM sheme, we included an optimization module to select the gain map components that minimize the reconstruction error, and consequently resulting in high fidelity HDR content. Comparisons with recent state-of-the-art methods have shown that our method provides better results in terms of visual quality and HDR reconstruction fidelity using objective and subjective evaluations.

  6. Cholesterol-diethylenetriaminepentaacetate complexed with thulium ions integrated into bicelles to increase their magnetic alignability.

    PubMed

    Liebi, Marianne; Kuster, Simon; Kohlbrecher, Joachim; Ishikawa, Takashi; Fischer, Peter; Walde, Peter; Windhab, Erich J

    2013-11-27

    Lanthanides have been used for several decades to increase the magnetic alignability of bicelles. DMPE-DTPA (1,2-dimyristoyl-sn-glycero-3-phospho-ethanolamine-diethylenetriaminepentaacetate) is commonly applied to anchor the lanthanides into the bicelles. However, because DMPE-DTPA has the tendency to accumulate at the highly curved edge region of the bicelles and if located there does not contribute to the magnetic orientation energy, we have tested cholesterol-DTPA complexed with thulium ions (Tm(3+)) as an alternative chelator to increase the magnetic alignability. Differential scanning calorimetric (DSC) measurements indicate the successful integration of cholesterol-DTPA into a DMPC (1,2-dimyristoyl-sn-glycero-3-phosphocholine) bilayer. Cryo transmission electron microscopy and small-angle neutron scattering (SANS) measurements show that the disklike structure, that is, bicelles, is maintained if cholesterol-DTPA·Tm(3+) is integrated into a mixture of DMPC, cholesterol, and DMPE-DTPA·Tm(3+). The size of the bicelles is increased compared to the size of the bicelles obtained from mixtures without cholesterol-DTPA·Tm(3+). Magnetic-field-induced birefringence and SANS measurements in a magnetic field show that with addition of cholesterol-DTPA·Tm(3+) the magnetic alignability of these bicelles is significantly increased compared to bicelles composed of DMPC, cholesterol, and DMPE-DTPA·Tm(3+) only.

  7. Modulated and continuous-wave operations of low-power thulium (Tm:YAP) laser in tissue welding

    NASA Astrophysics Data System (ADS)

    Bilici, Temel; Tabakoğlu, Haşim Özgür; Topaloğlu, Nermin; Kalaycıoğlu, Hamit; Kurt, Adnan; Sennaroglu, Alphan; Gülsoy, Murat

    2010-05-01

    Our aim is to explore the welding capabilities of a thulium (Tm:YAP) laser in modulated and continuous-wave (CW) modes of operation. The Tm:YAP laser system developed for this study includes a Tm:YAP laser resonator, diode laser driver, water chiller, modulation controller unit, and acquisition/control software. Full-thickness incisions on Wistar rat skin were welded by the Tm:YAP laser system at 100 mW and 5 s in both modulated and CW modes of operation (34.66 W/cm2). The skin samples were examined during a 21-day healing period by histology and tensile tests. The results were compared with the samples closed by conventional suture technique. For the laser groups, immediate closure at the surface layers of the incisions was observed. Full closures were observed for both modulated and CW modes of operation at day 4. The tensile forces for both modulated and CW modes of operation were found to be significantly higher than the values found by conventional suture technique. The 1980-nm Tm:YAP laser system operating in both modulated and CW modes maximizes the therapeutic effect while minimizing undesired side effects of laser tissue welding. Hence, it is a potentially important alternative tool to the conventional suturing technique.

  8. LANDSAT 4 investigations of Thematic Mapper and multispectral scanner applications. [Death Valley, California; Silver Bell Copper Mine, Arizona, and Dulles Airport near Washington, D.C.

    NASA Technical Reports Server (NTRS)

    Lauer, D. T. (Principal Investigator)

    1984-01-01

    The optimum index factor package was used to choose TM band for color compositing. Processing techniques were also used on TM data over several sites to: (1) reduce the amount of data that needs to be processed and analyzed by using statistical methods or by combining full-resolution products with spatially compressed products; (2) digitally process small subareas to improve the visual appearance of large-scale products or to merge different-resolution image data; and (3) evaluate and compare the information content of the different three-band combinations that can be made using the TM data. Results indicate that for some applications the added spectral information over MSS is even more important than the TM's increased spatial resolution.

  9. Systematic Refinement of a Health Information Technology Time and Motion Workflow Instrument for Inpatient Nursing Care using a Standardized Interface Terminology

    PubMed Central

    Zhang, Yi; Monsen, Karen A; Adam, Terrence J; Pieczkiewicz, David S; Daman, Megan; Melton, Genevieve B

    2011-01-01

    Time and motion (T&M) studies provide an objective method to measure the expenditure of time by clinicians. While some instruments for T&M studies have been designed to evaluate health information technology (HIT), these instruments have not been designed for nursing workflow. We took an existing open source HIT T&M study application designed to evaluate physicians in the ambulatory setting and rationally adapted it through empiric observations to record nursing activities in the inpatient setting and linked this instrument to an existing interface terminology, the Omaha System. Nursing activities involved several dimensions and could include multiple activities occurring simultaneously, requiring significant instrument redesign. 94% of the activities from the study instrument mapped adequately to the Omaha System. T&M study instruments require customization in design optimize them for different environments, such as inpatient nursing, to enable optimal data collection. Interface terminologies show promise as a framework for recording and analyzing T&M study data. PMID:22195228

  10. Detection of antibodies in human serum using trimellityl-erythrocytes: direct and indirect haemagglutination and haemolysis.

    PubMed

    Turner, E S; Pruzansky, J J; Patterson, R; Zeiss, C R; Roberts, M

    1980-02-01

    Utilizing trimellityl-erythrocytes (TM-E), antibodies were detected in sera of seven workers with trimellitic anhydride (TMA) induced airway syndromes by direct haemagglutination, indirect haemagglutination with anti-human IgG, IgA or IgM or by haemolysis. Detectable levels of antibody were obtained with all three methods. The most sensitive technique was indirect haemagglutination using anti-IgG. When added as an inhibitor, TM-human serum albumin produced a 10- to 800-fold reduction in titres. TM-ovalbumin of similar epitope density was less inhibitory and sodium trimellitate the least inhibitory on a molar basis. All of the assays using haptenized human red cells were also capable of detecting anti-TM antibodies in Rhesus monkeys whose airways had been exposed to TMA. These assays are useful for detecting anti-TM antibodies and may also be adapted to demonstrate antibodies induced against other inhaled haptens in sera of environmentally exposed individuals or in animal models of such exposure.

  11. Interpreting forest and grassland biome productivity utilizing nested scales of image resolution and biogeographical analysis

    NASA Technical Reports Server (NTRS)

    Iverson, L. R.; Olson, J. S.; Risser, P. G.; Treworgy, C.; Frank, T.; Cook, E.; Ke, Y.

    1986-01-01

    Data acquisition, initial site characterization, image and geographic information methods available, and brief evaluations of first-year for NASA's Thematic Mapper (TM) working group are presented. The TM and other spectral data are examined in order to relate local, intensive ecosystem research findings to estimates of carbon cycling rates over wide geographic regions. The effort is to span environments ranging from dry to moist climates and from good to poor site quality using the TM capability, with and without the inclusion of geographic information system (GIS) data, and thus to interpret the local spatial pattern of factors conditioning biomass or productivity. Twenty-eight TM data sets were acquired, archived, and evaluated. The ERDAS image processing and GIS system were installed on the microcomputer (PC-AT) and its capabilities are being investigated. The TM coverage of seven study areas were exported via ELAS software on the Prime to the ERDAS system. Statistical analysis procedures to be used on the spectral data are being identified.

  12. Gray QB-sing-faced version 2 (SF2) open environment test report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Plummer, J.; Immel, D.; Bobbitt, J.

    This report details the design upgrades incorporated into the new version of the GrayQbTM SF2 device and the characterization testing of this upgraded device. Results from controlled characterization testing in the Savannah River National Laboratory (SRNL) R&D Engineering Imaging and Radiation Lab (IRL) and the Savannah River Site (SRS) Health Physics Instrument Calibration Laboratory (HPICL) is presented, as well as results from the open environment field testing performed in the E-Area Low Level Waste Storage Area. Resultant images presented in this report were generated using the SRNL developed Radiation Analyzer (RAzerTM) software program which overlays the radiation contour images ontomore » the visual image of the location being surveyed.« less

  13. Room and Elevated Temperature Tensile Properties of Single Tow Hi-Nicalon, Carbon Interphase, CVI SiC Matrix Minicomposites

    NASA Technical Reports Server (NTRS)

    Martinez-Fernandez, J.; Morscher, G. N.

    2000-01-01

    Single tow Hi-Nicalon(TM), C interphase, CVI SiC matrix minicomposites were tested in tension at room temperature, 700 C, 950 C, and 1200 C in air. Monotonic loading with modal acoustic emission monitoring was performed at room temperature in order to determine the dependence of matrix cracking on applied load. Modal acoustic emission was shown to correlate directly with the number of matrix cracks formed. Elevated temperature constant load stress-rupture and low-cycle fatigue experiments were performed on precracked specimens. The elevated temperature rupture behavior was dependent on the precrack stress, the lower precrack stress resulting in longer rupture life for a given stress. It was found that the rupture lives of C-interphase Hi-Nicalon(TM) minicomposites were superior to C-interphase Ceramic Grade Nicalon(TM) minicomposites and inferior to those of BN-interphase Hi-Nicalon(TM) minicomposites.

  14. Functional traits of soil invertebrates as indicators for exposure to soil disturbance.

    PubMed

    Hedde, Mickaël; van Oort, Folkert; Lamy, Isabelle

    2012-05-01

    We tested a trait-based approach to link a soil disturbance to changes in invertebrate communities. Soils and macro-invertebrates were sampled in sandy soils contaminated by long-term wastewater irrigation, adding notably organic matter and trace metals (TM). We hypothesized that functional traits of invertebrates depict ways of exposure and that exposure routes relate to specific TM pools. Geophages and soft-body invertebrates were chosen to inform on exposure by ingestion or contact, respectively. Trait-based indices depicted more accurately effects of pollution than community density and diversity did. Exposure by ingestion had more deleterious effects than by contact. Both types of exposed invertebrates were influenced by TM, but geophages mainly responded to changes in soil organic matter contents. The trait-based approach requires to be applied in various conditions to uncorrelate specific TM impacts from those of other environmental factors. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. Binding modes of dihydroquinoxalinones in a homology model of bradykinin receptor 1.

    PubMed

    Ha, Sookhee N; Hey, Pat J; Ransom, Rick W; Harrell, C Meacham; Murphy, Kathryn L; Chang, Ray; Chen, Tsing-Bau; Su, Dai-Shi; Markowitz, M Kristine; Bock, Mark G; Freidinger, Roger M; Hess, Fred J

    2005-05-27

    We report the first homology model of human bradykinin receptor B1 generated from the crystal structure of bovine rhodopsin as a template. Using an automated docking procedure, two B1 receptor antagonists of the dihydroquinoxalinone structural class were docked into the receptor model. Site-directed mutagenesis data of the amino acid residues in TM1, TM3, TM6, and TM7 were incorporated to place the compounds in the binding site of the homology model of the human B1 bradykinin receptor. The best pose in agreement with the mutation data was selected for detailed study of the receptor-antagonist interaction. To test the model, the calculated antagonist-receptor binding energy was correlated with the experimentally measured binding affinity (K(i)) for nine dihydroquinoxalinone analogs. The model was used to gain insight into the molecular mechanism for receptor function and to optimize the dihydroquinoxalinone analogs.

  16. Wall-to-wall Landsat TM classifications for Georgia in support of SAFIS using FIA plots for training and verification

    Treesearch

    William H. Cooke; Andrew J. Hartsell

    2000-01-01

    Wall-to-wall Landsat TM classification efforts in Georgia require field validation. Validation uslng FIA data was testing by developing a new crown modeling procedure. A methodology is under development at the Southern Research Station to model crown diameter using Forest Health monitoring data. These models are used to simulate the proportion of tree crowns that...

  17. Middle School Students' Conceptual Learning from the Implementation of a New NSF Supported Curriculum: Interactions in Physical Science[TM

    ERIC Educational Resources Information Center

    Eick, Charles J.; Dias, Michael; Smith, Nancy R. Cook

    2009-01-01

    A new National Science Foundation supported curriculum, Interactions in Physical Science[TM], was evaluated on students' conceptual change in the twelve concept areas of the national physical science content standard (B) for grades 5-8. Eighth grade students (N = 66) were evaluated pre and post on a 31-item multiple-choice test of conceptual…

  18. Charge-Induced Force Noise on Free-Falling Test Masses: Results from LISA Pathfinder

    NASA Astrophysics Data System (ADS)

    Armano, M.; Audley, H.; Auger, G.; Baird, J. T.; Binetruy, P.; Born, M.; Bortoluzzi, D.; Brandt, N.; Bursi, A.; Caleno, M.; Cavalleri, A.; Cesarini, A.; Cruise, M.; Danzmann, K.; de Deus Silva, M.; Diepholz, I.; Dolesi, R.; Dunbar, N.; Ferraioli, L.; Ferroni, V.; Fitzsimons, E. D.; Flatscher, R.; Freschi, M.; Gallegos, J.; García Marirrodriga, C.; Gerndt, R.; Gesa, L.; Gibert, F.; Giardini, D.; Giusteri, R.; Grimani, C.; Grzymisch, J.; Harrison, I.; Heinzel, G.; Hewitson, M.; Hollington, D.; Hueller, M.; Huesler, J.; Inchauspé, H.; Jennrich, O.; Jetzer, P.; Johlander, B.; Karnesis, N.; Kaune, B.; Killow, C. J.; Korsakova, N.; Lloro, I.; Liu, L.; López-Zaragoza, J. P.; Maarschalkerweerd, R.; Madden, S.; Mance, D.; Martín, V.; Martin-Polo, L.; Martino, J.; Martin-Porqueras, F.; Mateos, I.; McNamara, P. W.; Mendes, J.; Mendes, L.; Moroni, A.; Nofrarias, M.; Paczkowski, S.; Perreur-Lloyd, M.; Petiteau, A.; Pivato, P.; Plagnol, E.; Prat, P.; Ragnit, U.; Ramos-Castro, J.; Reiche, J.; Romera Perez, J. A.; Robertson, D. I.; Rozemeijer, H.; Rivas, F.; Russano, G.; Sarra, P.; Schleicher, A.; Slutsky, J.; Sopuerta, C.; Sumner, T. J.; Texier, D.; Thorpe, J. I.; Trenkel, C.; Vetrugno, D.; Vitale, S.; Wanner, G.; Ward, H.; Wass, P. J.; Wealthy, D.; Weber, W. J.; Wittchen, A.; Zanoni, C.; Ziegler, T.; Zweifel, P.; LISA Pathfinder Collaboration

    2017-04-01

    We report on electrostatic measurements made on board the European Space Agency mission LISA Pathfinder. Detailed measurements of the charge-induced electrostatic forces exerted on free-falling test masses (TMs) inside the capacitive gravitational reference sensor are the first made in a relevant environment for a space-based gravitational wave detector. Employing a combination of charge control and electric-field compensation, we show that the level of charge-induced acceleration noise on a single TM can be maintained at a level close to 1.0 fm s-2 Hz-1 /2 across the 0.1-100 mHz frequency band that is crucial to an observatory such as the Laser Interferometer Space Antenna (LISA). Using dedicated measurements that detect these effects in the differential acceleration between the two test masses, we resolve the stochastic nature of the TM charge buildup due to interplanetary cosmic rays and the TM charge-to-force coupling through stray electric fields in the sensor. All our measurements are in good agreement with predictions based on a relatively simple electrostatic model of the LISA Pathfinder instrument.

  19. Charge-Induced Force Noise on Free-Falling Test Masses: Results from LISA Pathfinder.

    PubMed

    Armano, M; Audley, H; Auger, G; Baird, J T; Binetruy, P; Born, M; Bortoluzzi, D; Brandt, N; Bursi, A; Caleno, M; Cavalleri, A; Cesarini, A; Cruise, M; Danzmann, K; de Deus Silva, M; Diepholz, I; Dolesi, R; Dunbar, N; Ferraioli, L; Ferroni, V; Fitzsimons, E D; Flatscher, R; Freschi, M; Gallegos, J; García Marirrodriga, C; Gerndt, R; Gesa, L; Gibert, F; Giardini, D; Giusteri, R; Grimani, C; Grzymisch, J; Harrison, I; Heinzel, G; Hewitson, M; Hollington, D; Hueller, M; Huesler, J; Inchauspé, H; Jennrich, O; Jetzer, P; Johlander, B; Karnesis, N; Kaune, B; Killow, C J; Korsakova, N; Lloro, I; Liu, L; López-Zaragoza, J P; Maarschalkerweerd, R; Madden, S; Mance, D; Martín, V; Martin-Polo, L; Martino, J; Martin-Porqueras, F; Mateos, I; McNamara, P W; Mendes, J; Mendes, L; Moroni, A; Nofrarias, M; Paczkowski, S; Perreur-Lloyd, M; Petiteau, A; Pivato, P; Plagnol, E; Prat, P; Ragnit, U; Ramos-Castro, J; Reiche, J; Romera Perez, J A; Robertson, D I; Rozemeijer, H; Rivas, F; Russano, G; Sarra, P; Schleicher, A; Slutsky, J; Sopuerta, C; Sumner, T J; Texier, D; Thorpe, J I; Trenkel, C; Vetrugno, D; Vitale, S; Wanner, G; Ward, H; Wass, P J; Wealthy, D; Weber, W J; Wittchen, A; Zanoni, C; Ziegler, T; Zweifel, P

    2017-04-28

    We report on electrostatic measurements made on board the European Space Agency mission LISA Pathfinder. Detailed measurements of the charge-induced electrostatic forces exerted on free-falling test masses (TMs) inside the capacitive gravitational reference sensor are the first made in a relevant environment for a space-based gravitational wave detector. Employing a combination of charge control and electric-field compensation, we show that the level of charge-induced acceleration noise on a single TM can be maintained at a level close to 1.0  fm s^{-2} Hz^{-1/2} across the 0.1-100 mHz frequency band that is crucial to an observatory such as the Laser Interferometer Space Antenna (LISA). Using dedicated measurements that detect these effects in the differential acceleration between the two test masses, we resolve the stochastic nature of the TM charge buildup due to interplanetary cosmic rays and the TM charge-to-force coupling through stray electric fields in the sensor. All our measurements are in good agreement with predictions based on a relatively simple electrostatic model of the LISA Pathfinder instrument.

  20. Detection of soil erosion within pinyon-juniper woodlands using Thematic Mapper (TM) data

    NASA Technical Reports Server (NTRS)

    Price, Kevin P.

    1993-01-01

    Multispectral measurements collected by Landsat Thematic Mapper (TM) were correlated with field measurements, direct soil loss estimates, and Universal Soil Loss Equation (USLE) estimates to determine the sensitivity of TM data to varying degrees of soil erosion in pinyon-juniper woodland in central Utah. TM data were also evaluated as a predictor of the USLE Crop Management C factor for pinyon-juniper woodlands. TM spectral data were consistently better predictors of soil erosion factors than any combination of field factors. TM data were more sensitive to vegetation variations than the USLE C factor. USLE estimates showed low annual rates of erosion which varied little among the study sites. Direct measurements of rate of soil loss using the SEDIMENT (Soil Erosion DIrect measureMENT) technique, indicated high and varying rates of soil loss among the sites since tree establishment. Erosion estimates from the USLE and SEDIMENT methods suggest that erosion rates have been severe in the past, but because significant amounts of soil have already been eroded, and the surface is now armored by rock debris, present erosion rates are lower. Indicators of accelerated erosion were still present on all sites, however, suggesting that the USLE underestimated erosion within the study area.

  1. A new voxel-based model for the determination of atmospheric weighted mean temperature in GPS atmospheric sounding

    NASA Astrophysics Data System (ADS)

    He, Changyong; Wu, Suqin; Wang, Xiaoming; Hu, Andong; Wang, Qianxin; Zhang, Kefei

    2017-06-01

    The Global Positioning System (GPS) is a powerful atmospheric observing system for determining precipitable water vapour (PWV). In the detection of PWV using GPS, the atmospheric weighted mean temperature (Tm) is a crucial parameter for the conversion of zenith tropospheric delay (ZTD) to PWV since the quality of PWV is affected by the accuracy of Tm. In this study, an improved voxel-based Tm model, named GWMT-D, was developed using global reanalysis data over a 4-year period from 2010 to 2013 provided by the United States National Centers for Environmental Prediction (NCEP). The performance of GWMT-D was assessed against three existing empirical Tm models - GTm-III, GWMT-IV, and GTmN - using different data sources in 2014 - the NCEP reanalysis data, surface Tm data provided by Global Geodetic Observing System and radiosonde measurements. The results show that the new GWMT-D model outperforms all the other three models with a root-mean-square error of less than 5.0 K at different altitudes over the globe. The new GWMT-D model can provide a practical alternative Tm determination method in real-time GPS-PWV remote sensing systems.

  2. Double NIR laser stimulation and enhancing the thermal sensitivity of Er3+/Tm3+/Nd3+ doped multilayer core-shell nanoparticles.

    PubMed

    Ba, Zhaojing; Hu, Min; Zhao, Yiming; Wang, Yiqing; Wang, Jing; Zhang, Zhenxi

    2018-08-31

    Non-contact thermal sensors are important devices to study cellular processes and monitor temperature in vivo. Herein, a novel highly sensitive nanothermometer based on NaYF 4 :Yb,Er@ NaYF 4 @NaYF 4 :Yb,Tm@ NaYF 4 :Nd (denoted as Er@Y@Tm@Nd) was prepared by a facile solvothermal method. When excited by the near-infrared (NIR) light of 808 and 980 nm, the as-prepared Er@Y@Tm@Nd nanoparticles could emit both blue and green light, respectively, since the lanthanide cations responsible for these emissions are gathered inside this nanostructure. The green and blue light intensity ratio exhibits obvious temperature dependence in the range of the physiological temperature. Additionally, the fluorescence intensity of Er 3+ and Tm 3+ are also greatly enhanced due to the multilayer structure that implies avoiding the Er 3+ and Tm 3+ energy cross-relaxation by introduction of a NaYF 4 wall between them. The as-prepared core-shell-shell-shell structure with Er 3+ and Tm 3+ in different layers improves dozens of times of the thermal sensitivity based on the non-thermal coupling levels of the probe: the maximum values for the sensitivity are 2.95% K -1 (I Er-521 /I Tm-450 ) and 6.30% K -1 (I Tm-474 /I Er-541 ) when excited by 980 and 808 nm laser sources, respectively. These values are well above those previously reported (<0.7% K -1 ), indicating that the prepared nanostructures are temperature sensors with excellent thermal sensitivity and sensitive to NIR wavelength excitation that makes them highly preferred for thermal detection.

  3. PNPLA3 rs738409 and TM6SF2 rs58542926 variants increase the risk of hepatocellular carcinoma in alcoholic cirrhosis.

    PubMed

    Falleti, Edmondo; Cussigh, Annarosa; Cmet, Sara; Fabris, Carlo; Toniutto, Pierluigi

    2016-01-01

    PNPLA3 rs738409 polymorphism is associated with fatty liver disease, alcoholic or non-alcoholic (NAFLD) and hepatocellular carcinoma (HCC). TM6SF2 rs58542926 is clearly associated with NAFLD, but it is not clearly associated with HCC. The relationship between TM6SF2 rs58542926 and HCC and the potential synergistic effect of TM6SF2 and PNPLA3 variants in modifying the risk of HCC are not known. This study assessed the interaction between PNPLA3 rs738409 and TM6SF2 rs58542926 variants in the conditioning of HCC development. A total of 511 cirrhotic patients (44% alcohol-related, 56% viral, 57.5% liver transplanted) were retrospectively investigated for HCC occurrence. PNPLA3 rs734809 and TM6SF2 rs58542926 were genotyped using restriction fragment length polymorphism and real-time allelic discrimination polymerase chain reaction methods. Patients with HCC were more likely to be PNPLA3 rs734809 G/G homozygotes (41/150 vs. 60/361, p=0.009) or TM6SF2 rs58542926 C/T-T/T (27/150 vs. 41/361, p=0.044). The presence of either PNPLA3 G/G or TM6SF2*/T identified high-risk genotypes for HCC, which were strongly associated with HCC (64/150 vs. 93/361, p=0.0002). This association was evident in alcohol-related (p=0.0007) but not in viral cirrhosis. TM6SF2 C/T or T/T in conjunction with PNPLA3 G/G variants may be potential genetic risk factors for developing HCC in alcohol-related cirrhosis. Copyright © 2015 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  4. Near-infrared quantum-cutting luminescence and energy transfer properties of Ca{sub 3}(PO{sub 4}){sub 2}:Tm{sup 3+},Ce{sup 3+} phosphors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dong, S. L.; Lin, H. H., E-mail: linhh@hstc.edu.cn, E-mail: qyzhang@scut.edu.cn; Yu, T.

    2014-07-14

    The phosphors Ca{sub 3}(PO{sub 4}){sub 2}:Tm{sup 3+} by co-doping Ce{sup 3+} have been synthesized by conventional high-temperature solid-state reaction method. Their spectroscopic properties in the UV-VIS-NIR range have been investigated. The first 5d crystal field level location and stokes shift have been determined from the UV excitation and emission spectra of Ca{sub 3}(PO{sub 4}){sub 2}:Ce{sup 3+}. The three-photon NIR quantum-cutting luminescence of Tm{sup 3+} assigned to the electronic transitions of {sup 1}G{sub 4}→{sup 3}H{sub 4}, {sup 3}H{sub 4}→{sup 3}F{sub 4} and {sup 3}F{sub 4}→{sup 3}H{sub 6} is observed, whether in Ca{sub 3}(PO{sub 4}){sub 2}:Tm{sup 3+} or Ca{sub 3}(PO{sub 4}){sub 2}:Tm{supmore » 3+},Ce{sup 3+}. The energy transfer from Ce{sup 3+} to Tm{sup 3+} takes place with energy-transfer efficiency up to 34.5% for the Ca{sub 3}(PO{sub 4}){sub 2}:Tm{sup 3+},Ce{sup 3+}. A cross relaxation scheme using the 5d states of Ce{sup 3+} and f-f transition of Tm{sup 3+} is proposed. The mechanism is revealed from energy level and decay measurements. The results show that the broadband absorption of Ce{sup 3+} sensitizer not only extends the spectrum conversion in UV region but also greatly enhances the photoluminescence intensities of the three-photon quantum cutting luminescence of Tm{sup 3+} doped Ca{sub 3}(PO{sub 4}){sub 2}.« less

  5. GPS PPP-derived precipitable water vapor retrieval based on Tm/Ps from multiple sources of meteorological data sets in China

    NASA Astrophysics Data System (ADS)

    Zhang, Hongxing; Yuan, Yunbin; Li, Wei; Ou, Jikun; Li, Ying; Zhang, Baocheng

    2017-04-01

    Weighted mean temperature (Tm) and pressure (Ps) are two parameters of great relevance to precipitable water vapor (PWV) retrieval from global positioning system (GPS) data. However, information about the Tm and Ps cannot be available for those GPS stations that are not colocated with meteorological sensors. To investigate the optimal GPS-PWV retrieval method for China, two enhanced Tm models, GM-Tm (temperature dependent) and GH-Tm (temperature independent), are developed. Additionally, the potentials of the Ps data from the two reanalysis data sets, the National Centers for Environmental Prediction (NCEP)-Department of Energy (DOE) Reanalysis II (NCEP II) and ERA-Interim, and from the empirical model GPT2w for GPS-PWV retrieval are investigated over China. To evaluate the performances of multisources Tm and Ps data for GPS-PWV retrieval, GPS data (2011-2013) collected from 22 stations of the Crustal Movement Observation Network of China (CMONOC) were processed by using the precise point positioning (PPP) technique, estimating the zenith tropospheric delay (ZTD) so as to be subsequently converted to GPS-PWV. The retrieved GPS-PWVs are compared with their counterparts derived from NCEP II and radiosonde data over China. The results show that (1) the GM-Tm model consistently shows the highest accuracy (with root mean square error of 2.3 K), and the GH-Tm model should be selected when temperature observations are not available, and that (2) the performances of Ps from NCEP II and ERA-Interim differ marginally for GPS-PWV retrieval, and significant seasonal variations are found in the agreement between the GPS-PWVs and the PWVs derived from NCEP II and radiosonde data over China.

  6. [Expression optimization and characterization of Tenebrio molitor antimicrobiol peptides TmAMP1m in Escherichia coli].

    PubMed

    Alimu, Reyihanguli; Mao, Xinfang; Liu, Zhongyuan

    2013-06-01

    To improve the expression level of tmAMP1m gene from Tenebrio molitor in Escherichia coli, we studied the effects of expression level and activity of the fusion protein HIS-TmAMP1m by conditions, such as culture temperature, inducing time and the final concentration of inductor Isopropyl beta-D-thiogalactopyranoside (IPTG). We analyzed the optimum expression conditions by Tricine-SDS-PAGE electrophoresis, meanwhile, detected its antibacterial activity by using agarose cavity diffusion method. The results suggest that when inducing the recombinant plasmid with a final IPTG concentration of 0.1 mmol/L at 37 degrees C for 4 h, there was the highest expression level of fusion protein HIS-TmAMP1m in Escherichia coli. Under these conditions, the expression of fusion protein accounted for 40% of the total cell lysate with the best antibacterial activity. We purified the fusion protein HIS-TmAMPlm with nickel-nitrilotriacetic acid (Ni-NTA) metal-affinity chromatography matrices. Western blotting analysis indicates that the His monoclonal antibody could be specifically bound to fusion protein HIS-TmAMPlm. After expression by inducing, the fusion protein could inhibit the growth of host cell transformed by pET30a-tmAMP1m. The fusion protein HIS-TmAMP1m had better stability and remained higher antibacterial activities when incubated at 100 degrees C for 10 h, repeated freeze thawing at -20 degrees C, dissolved in strong acid and alkali, or treated by organic solvents and protease. Moreover, the minimum inhibitory concentration results demonstrated that the fusion protein HIS-TmAMP1m has a good antibacterial activity against Staphylococcus aureus, Staphylococcus sp., Corynebacterium glutamicum, Bacillus thuringiensis, Corynebacterium sp. This study laid the foundation to promote the application of insect antimicrobial peptides and further research.

  7. Phase-sensitive optical coherence tomography characterization of pulse-induced trabecular meshwork displacement in ex vivo non-human primate eyes

    NASA Astrophysics Data System (ADS)

    Li, Peng; Reif, Roberto; Zhi, Zhongwei; An, Lin; Martin, Elizabeth; Shen, Tueng T.; Johnstone, Murray; Wang, Ruikang K.

    2013-03-01

    Purpose. It is suspected that the abnormalities of aqueous outflow pump composed of trabecular meshwork (TM) and Schlemm's canal (SC) results in the increased outflow resistance and then elevated intraocular pressure (IOP) in initial glaucoma. In order to explore the casual mechanism and the early diagnosis of glaucoma, the dynamic characterizations of aqueous outflow pump were explored. Methods. As a functional extension of optical coherence tomography (OCT), tissue Doppler OCT (tissue-DOCT) method capable of measuring the slow tissue movement was developed. The tissue-DOCT imaging was conducted on the corneo-scleral limbus of 4 monkey eyes. The eye was mounted in an anterior segment holder, together with a perfusion system to control the mean IOP and to induce the cyclic IOP transients with amplitude 3 mm Hg at frequency 1 pulse/second. IOP was monitored on-line by a pressure transducer. Tissue-DOCT data and pressure data were recorded simultaneously. The IOP-transient induced Doppler velocity, displacement and strain rate of TM and the normalized area of SC were quantified at 7 different mean IOPs (5, 8, 10, 20, 30, 40, 50 mm Hg). Results. The outflow system, including TM, SC and CCs, was visualized in the micro-structural imaging. The IOP-transient induced pulsatile TM movement and SC deformation were detected and quantified by tissue-DOCT. The TM movement was depth-dependent and the largest movement was located in the area closest to SC endothelium (SCE). Both the pulsations of TM and SC were found to be synchronous with the IOP pulse wave. At 8 mm Hg IOP, the global TM movement was around 0.65μm during one IOP transient. As IOP elevated, a gradual attenuation of TM movement and SC deformation was observed. Conclusions. The observed pulsation of TM and SC induced by the pulsatile IOP transients was in good agreement with the predicated role of TM and SC acting as a biomechanical pump (pumping aqueous from anterior chamber into SC and from SC into CCs) in the aqueous outflow system. As the IOP elevated, the attenuated pulsation amplitude of the aqueous outflow pump indicated the failure of the mechanical pump and the increase of aqueous outflow resistance. The promising results revealed the potential of using the proposed tissue-DOCT for diagnosis and associated therapeutic guidance of the initial and progressive glaucoma process by monitoring the pulsation of the outflow pump.

  8. Progress toward determining the potential of ODS alloys for gas turbine applications

    NASA Technical Reports Server (NTRS)

    Dreshfield, R. L.; Hoppin, G., III; Sheffler, K.

    1983-01-01

    The Materials for Advanced Turbine Engine (MATE) Program managed by the NASA Lewis Research Center is supporting two projects to evaluate the potential of oxide dispersion strengthened (ODS) alloys for aircraft gas turbine applications. One project involves the evaluation of Incoloy (TM) MA-956 for application as a combustor liner material. An assessment of advanced engine potential will be conducted by means of a test in a P&WA 2037 turbofan engine. The other project involves the evaluation of Inconel (TM) MA 6000 for application as a high pressure turbine blade material and includes a test in a Garrett TFE 731 turbofan engine. Both projects are progressing toward these engine tests in 1984.

  9. A Systematic Review of Interventions to Enhance Healthy Lifestyle Behaviors in Adolescents Delivered via Mobile Phone Text Messaging.

    PubMed

    Loescher, Lois J; Rains, Stephen A; Kramer, Sandra S; Akers, Chelsie; Moussa, Renee

    2018-05-01

    To systematically review healthy lifestyle interventions targeted to adolescents and delivered using text messaging (TM). PubMed, Embase, CINAHL, PsycINFO, and Web of Science databases. Study Inclusion Criteria: Research articles published during 2011 to 2014; analyses focused on intervention targeting adolescents (10-19 years), with healthy lifestyle behaviors as main variables, delivered via mobile phone-based TM. The authors extracted data from 27 of 281 articles using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses method. Adolescent and setting characteristics, study design and rigor, intervention effectiveness, challenges, and risk of bias. Across studies, 16 (59.3%) of 27 included non-Caucasians. The gender was split for 22 (81.5%) of 27 studies. Thirteen studies were randomized controlled trials. There was heterogeneity among targeted conditions, rigor of methods, and intervention effects. Interventions for monitoring/adherence (n = 8) reported more positive results than those for health behavior change (n = 19). Studies that only included message delivered via TM (n = 14) reported more positive effects than studies integrating multiple intervention components. Interventions delivered using TM presented minimal challenges, but selection and performance bias were observed across studies. Interventions delivered using TM have the potential, under certain conditions, to improve healthy lifestyle behaviors in adolescents. However, the rigor of studies varies, and established theory and validated measures have been inconsistently incorporated.

  10. Full-field transient vibrometry of the human tympanic membrane by local phase correlation and high-speed holography

    PubMed Central

    Dobrev, Ivo; Furlong, Cosme; Cheng, Jeffrey T.; Rosowski, John J.

    2014-01-01

    Abstract. Understanding the human hearing process would be helped by quantification of the transient mechanical response of the human ear, including the human tympanic membrane (TM or eardrum). We propose a new hybrid high-speed holographic system (HHS) for acquisition and quantification of the full-field nanometer transient (i.e., >10  kHz) displacement of the human TM. We have optimized and implemented a 2+1 frame local correlation (LC) based phase sampling method in combination with a high-speed (i.e., >40  K fps) camera acquisition system. To our knowledge, there is currently no existing system that provides such capabilities for the study of the human TM. The LC sampling method has a displacement difference of <11  nm relative to measurements obtained by a four-phase step algorithm. Comparisons between our high-speed acquisition system and a laser Doppler vibrometer indicate differences of <10  μs. The high temporal (i.e., >40  kHz) and spatial (i.e., >100  k data points) resolution of our HHS enables parallel measurements of all points on the surface of the TM, which allows quantification of spatially dependent motion parameters, such as modal frequencies and acoustic delays. Such capabilities could allow inferring local material properties across the surface of the TM. PMID:25191832

  11. A thickness-mode piezoelectric micromachined ultrasound transducer annular array using a PMN–PZT single crystal

    NASA Astrophysics Data System (ADS)

    Kang, Woojin; Jung, Joontaek; Lee, Wonjun; Ryu, Jungho; Choi, Hongsoo

    2018-07-01

    Micro-electromechanical system (MEMS) technologies were used to develop a thickness-mode piezoelectric micromachined ultrasonic transducer (Tm-pMUT) annular array utilizing a lead magnesium niobate–lead zirconate titanate (PMN–PZT) single crystal prepared by the solid-state single-crystal-growth method. Dicing is a conventional processing method for PMN–PZT single crystals, but MEMS technology can be adopted for the development of Tm-pMUT annular arrays and has various advantages, including fabrication reliability, repeatability, and a curved element shape. An inductively coupled plasma–reactive ion etching process was used to etch a brittle PMN–PZT single crystal selectively. Using this process, eight ring-shaped elements were realized in an area of 1  ×  1 cm2. The resonance frequency and effective electromechanical coupling coefficient of the Tm-pMUT annular array were 2.66 (±0.04) MHz, 3.18 (±0.03) MHz, and 30.05%, respectively, in the air. The maximum positive acoustic pressure in water, measured at a distance of 7.27 mm, was 40 kPa from the Tm-pMUT annular array driven by a 10 Vpp sine wave at 2.66 MHz without beamforming. The proposed Tm-pMUT annular array using a PMN–PZT single crystal has the potential for various applications, such as a fingerprint sensor, and for ultrasonic cell stimulation and low-intensity tissue stimulation.

  12. Automatic detection of motor unit innervation zones of the external anal sphincter by multichannel surface EMG.

    PubMed

    Ullah, Khalil; Cescon, Corrado; Afsharipour, Babak; Merletti, Roberto

    2014-12-01

    A method to detect automatically the location of innervation zones (IZs) from 16-channel surface EMG (sEMG) recordings from the external anal sphincter (EAS) muscle is presented in order to guide episiotomy during child delivery. The new algorithm (2DCorr) is applied to individual motor unit action potential (MUAP) templates and is based on bidimensional cross correlation between the interpolated image of each MUAP template and two images obtained by flipping upside-down (around a horizontal axis) and left-right (around a vertical axis) the original one. The method was tested on 640 simulated MUAP templates of the sphincter muscle and compared with previously developed algorithms (Radon Transform, RT; Template Match, TM). Experimental signals were detected from the EAS of 150 subjects using an intra-anal probe with 16 equally spaced circumferential electrodes. The results of the three algorithms were compared with the actual IZ location (simulated signal) and with IZ location provided by visual analysis (VA) (experimental signals). For simulated signals, the inter quartile error range (IQR) between the estimated and the actual locations of the IZ was 0.20, 0.23, 0.42, and 2.32 interelectrode distances (IED) for the VA, 2DCorr, RT and TM methods respectively. Copyright © 2014 Elsevier Ltd. All rights reserved.

  13. Generalization of treadmill perturbation to overground slip during gait: Effect of different perturbation distances on slip recovery.

    PubMed

    Lee, Anna; Bhatt, Tanvi; Pai, Yi-Chung

    2016-01-25

    Treadmill-perturbation training (TM-training) may improve a person׳s fall-resistance, whereby adjusting slip distance can be a simple way to manipulate training intensity. The purpose of this study was to determine the effects of different slip distances in TM-training (12-cm vs. 18-cm) on its generalization to the recovery from a novel "free" slip during overground walking. Generalization here means the ability to apply learned skill from TM-training to slip recovery during overground walking. Thirty-six young adults in the TM_12 or the TM_18 group underwent either a 12-cm or an 18-cm slip during the treadmill walking for seven times, or in the control group were not exposed to any perturbation. Their responses were also contrasted with previously reported results from overground-perturbation training (OG-training) in which participants received either a 12-cm or an 18-cm slip during level walking with the same number of repetitions. Everyone was then exposed to the same generalization test during a novel "free" slip in overground walking. Their proactive and reactive control of stability was measured and compared. TM-training displayed a significant training effect in comparison to the control group (p<0.05), while most of the improvements were found in the reactive control of stability and were much-limited in comparison to that of OG-training. Also unlike OG-training, no significant differences were found between the results obtained from the TM_12 and the TM_18 groups (p>0.05). These results underscore the further needs to investigate the potential of the treadmill as a convenient instrument that can effectively deliver perturbation training. Published by Elsevier Ltd.

  14. A Taiwanese Mandarin Main Concept Analysis (TM-MCA) for quantification of aphasic oral discourse.

    PubMed

    Kong, Anthony Pak-Hin; Yeh, Chun-Chih

    2015-01-01

    Various quantitative systems have been proposed to examine aphasic oral narratives in English. A clinical tool for assessing discourse produced by Cantonese-speaking persons with aphasia (PWA), namely Main Concept Analysis (MCA), was developed recently for quantifying the presence, accuracy and completeness of a narrative. Similar tools for Mandarin speakers are currently absent. The first aim is to develop and establish the validity of the Taiwanese Mandarin Main Concept Analysis (TM-MCA) for the Mandarin-speaking population in Taiwan, given the paucity of related investigations. Another aim is to establish the influence of age and education level on Taiwanese Mandarin speakers' oral narrative abilities. The third purpose is to examine how well the TM-MCA could distinguish between native speakers with and without aphasia in Taiwan. The final aim is to examine the reliability and validity of the TM-MCA. Eight speech-language pathologists (SLPs) and eight neurologically intact participants were involved to establish the TM-MCA main concepts. Another 36 neurologically intact participants and 10 PWA participated to validate the TM-MCA by contrasting their performance. Both age and educational level affected the oral discourse performance among the neurologically intact adults. Significant differences on the TM-MCA measures were noted between the control group and the group with aphasia. Moreover, the degree of aphasia significantly affected the oral discourse of PWA. The TM-MCA is a culturally appropriate quantitative system for the Taiwanese Mandarin population. It can be used to supplement standardized aphasia tests to help SLPs make more informative decisions not only on clinical diagnosis but also on treatment planning. © 2015 Royal College of Speech and Language Therapists.

  15. Generalization of treadmill perturbation to overground slip during gait: Effect of different perturbation distances on slip recovery

    PubMed Central

    Lee, Anna; Bhatt, Tanvi; Pai, Yi-Chung

    2016-01-01

    Treadmill-perturbation training (TM-training) may improve a person’s fall-resistance, whereby adjusting slip distance can be a simple way to manipulate training intensity. The purpose of this study was to determine the effects of different slip distances in TM-training (12-cm vs. 18-cm) on its generalization to the recovery from a novel “free” slip during overground walking. Generalization here means the ability to apply learned skill from TM-training to slip recovery during overground walking. Thirty-six young adults in the TM_12 or the TM_18 group underwent either a 12-cm or an 18-cm slip during the treadmill walking for seven times, or in the control group were not exposed to any perturbation. Their responses were also contrasted with previously reported results from overground-perturbation training (OG-training) in which participants received either a 12-cm or an 18-cm slip during level walking with the same number of repetitions. Everyone was then exposed to the same generalization test during a novel “free” slip in overground walking. Their proactive and reactive control of stability was measured and compared. TM-training displayed a significant training effect in comparison to the control group (p<0.05), while most of the improvements were found in the reactive control of stability and were much-limited in comparison to that of OG-training. Also unlike OG-training, no significant differences were found between the results obtained from the TM_12 and the TM_18 groups (p>0.05). These results underscore the further needs to investigate the potential of the treadmill as a convenient instrument that can effectively deliver perturbation training. PMID:26653674

  16. Ethical and regulatory issues surrounding African traditional medicine in the context of HIV/AIDS.

    PubMed

    Nyika, Aceme

    2007-04-01

    It has been estimated that more than 80% of people in Africa use traditional medicine (TM). With the HIV/AIDS epidemic claiming many lives in Africa, the majority of people affected rely on TM mainly because it is relatively affordable and available to the poor populations who cannot afford orthodox medicine. Whereas orthodox medicine is practiced under stringent regulations and ethical guidelines emanating from The Nuremburg Code, African TM seems to be exempt from such scrutiny. Although recently there have been calls for TM to be incorporated into the health care system, less emphasis has been placed on ethical and regulatory issues. In this paper, an overview of the use of African TM in general, and for HIV/AIDS in particular, is given, followed by a look at: (i) the relative laxity in the application of ethical standards and regulatory requirements with regards to TM; (ii) the importance of research on TM in order to improve and demystify its therapeutic qualities; (iii) the need to tailor-make intellectual property laws to protect traditional knowledge and biodiversity. A framework of partnerships involving traditional healers' associations, scientists, policy makers, patients, community leaders, members of the communities, and funding organizations is suggested as a possible method to tackle these issues. It is hoped that this paper will stimulate objective and constructive debate that could enhance the protection of patients' welfare.

  17. LANDSAT-D investigations in snow hydrology

    NASA Technical Reports Server (NTRS)

    Dozier, J.

    1983-01-01

    Progress on the registration of TM data to digital topographic data; on comparison of TM, MSS and NOAA meteorological satellite data for snowcover mapping; and on radiative transfer models for atmospheric correction is reported. Some methods for analyzing spatial contiguity of snow within the snow covered area were selected. The methods are based on a two-channel version of the grey level co-occurence matrix, combined with edge detection derived from an algorithm for computing slopes and exposures from digital terrain data.

  18. Standard software for automated testing of infrared imagers, IRWindows, in practical applications

    NASA Astrophysics Data System (ADS)

    Irwin, Alan; Nicklin, Robert L.

    1998-08-01

    In the past, ad-hoc and manual testing of infrared images hasn't been a deterrent to the characterization of these systems due to the low volume of production and high ratio of skilled personnel to the quantity of units under test. However, with higher volume production, increasing numbers of development labs in emerging markets, and the push towards less expensive, faster development cycles, there is a strong need for standardized testing that is quickly configurable by test engineers, which can be run by less experienced test technicians, and which produce repeatable, accurate results. The IRWindowsTM system addresses these needs using a standard computing platform and existing automated IR test equipment. This paper looks at the general capabilities of the IRWindowsTM system, and then examines the specific results from its application in the PalmIR and Automotive IR production environments.

  19. Real-time automated thickness measurement of the in vivo human tympanic membrane using optical coherence tomography.

    PubMed

    Hubler, Zita; Shemonski, Nathan D; Shelton, Ryan L; Monroy, Guillermo L; Nolan, Ryan M; Boppart, Stephen A

    2015-02-01

    Otitis media (OM), an infection in the middle ear, is extremely common in the pediatric population. Current gold-standard methods for diagnosis include otoscopy for visualizing the surface features of the tympanic membrane (TM) and making qualitative assessments to determine middle ear content. OM typically presents as an acute infection, but can progress to chronic OM, and after numerous infections and antibiotic treatments over the course of many months, this disease is often treated by surgically inserting small tubes in the TM to relieve pressure, enable drainage, and provide aeration to the middle ear. Diagnosis and monitoring of OM is critical for successful management, but remains largely qualitative. We have developed an optical coherence tomography (OCT) system for high-resolution, depth-resolved, cross-sectional imaging of the TM and middle ear content, and for the quantitative assessment of in vivo TM thickness including the presence or absence of a middle ear biofilm. A novel algorithm was developed and demonstrated for automatic, real-time, and accurate measurement of TM thickness to aid in the diagnosis and monitoring of OM and other middle ear conditions. The segmentation algorithm applies a Hough transform to the OCT image data to determine the boundaries of the TM to calculate thickness. The use of OCT and this segmentation algorithm is demonstrated first on layered phantoms and then during real-time acquisition of in vivo OCT from humans. For the layered phantoms, measured thicknesses varied by approximately 5 µm over time in the presence of large axial and rotational motion. In vivo data also demonstrated differences in thicknesses both spatially on a single TM, and across normal, acute, and chronic OM cases. Real-time segmentation and thickness measurements of image data from both healthy subjects and those with acute and chronic OM demonstrate the use of OCT and this algorithm as a robust, quantitative, and accurate method for use during real-time in vivo human imaging.

  20. Impacts of river-bed aggradation and lahar activity downstream of Santiaguito Volcano, Guatemala: a Landsat Thematic Mapper perspective

    NASA Astrophysics Data System (ADS)

    Flynn, L. P.; Harris, A. J.; Davies, M. A.; Vallence, J. W.; Rose, W. I.

    2002-12-01

    Lava extrusion at Santiaguito volcano, Guatemala and rainfall runoff cause lahars and river-bed aggradation downstream of the volcano. We present a method that uses vegetation indices extracted from Landsat Thematic Mapper (TM) data to identify zones of impact. The method differentiates vegetation-free and vegetated pixels, constrains areas affected by aggradation, and generates catchment-wide aggradation maps. Application of the technique to 22 TM images acquired between 1987 and 2000 helped us to measure, map and track temporal and spatial variations in the area of lahar impact and river aggradation. To verify our TM-based analyses we carried out 3 field campaigns between 2000 and 2002, during which we focused on a segment of aggraded river beds ~8 km from Santiaguito. We then used our TM and field-based studies to document and validate changes at this location, as follows: (1) Time varying effects of aggradation. The main river to head at Santiaguito is R¡o Nima II. The TM analysis indicated development of a new channel cutting across farm land on the western edge of R¡o Nima II between 1996 and 2000. Field checking showed that development of an aggraded, convex, bed profile caused channels to flow westward away from the aggraded river-channel system. (2) Emplacement of lava flows. The TM time series indicated that a new lava flow extended into the upper reaches of the Rio Nima I during 1996 and triggered aggradation. Field checking confirmed that a new supply of volcaniclastic material had extended aggradation into this previously unaffected drainage. (3) River capture. Capture of R¡o Nima I by R¡o Samal has increased aggradation of along new sections of R¡o Samal , an effect evident in our TM mapping. Field checking showed that, although R¡o Samala does not head at Santiaguito, the new supply of material from R¡o Nima I triggered rapid aggradation of R¡o Samal after 1996.

  1. PETER: A Hardware Simulator for the Test Mass-GRS System of LISA Pathfinder

    NASA Astrophysics Data System (ADS)

    Marconi, L.; Stanga, R.; Bassan, M.; De Marchi, F.; Pucacco, G.; Visco, M.; Di Fiore, L.; De Rosa, R.; Garufi, F.

    2013-01-01

    Each LISA PathFinder test mass (TM) will be sensitive to forces along all its 6 Degrees of Freedom (DoFs). Extensive ground testing is required in order to evaluate the influence of cross-talks from the read-out and actuator channels. In the INFN laboratory of Firenze we have developed a facility for a good representation of the free fall conditions of the TM on flight. A hollow replica of a TM hanging from a double torsion pendulum can move inside a Gravitational Reference Sensor (GRS) with quasi free fall condition on two Dofs, in the frequency band (0.1 ÷ 100)mHz. On both DoFs, the target residual accelerations (yet to be achieved) at the low end frequency range are ≤ 3 × 10-13ms-2, limited by the thermal noise of the fibres. At higher frequencies, the sensitivity is limited by the readout noise of the readout, a replica of the flight electronics. After a long commissioning, we are now in operating conditions, and can carry out a series of experiments to better qualify the interaction between TM and GRS. In this paper we will show some significant qualification measurements and a first scientific measurements, i.e. the measurement and compensation of the DC bias in the GRS using two independent channels, as well as a measurement of the residual acceleration of the translational DoF, with the feedback loop closed on the rotational one, and viceversa.

  2. Biodegradable shape-memory block co-polymers for fast self-expandable stents.

    PubMed

    Xue, Liang; Dai, Shiyao; Li, Zhi

    2010-11-01

    Block co-polymers PCTBVs (M(n) of 36,300-65,300 g/mol, T(m) of 39-40 and 142 degrees C) containing hyperbranched three-arm poly(epsilon-caprolactone) (PCL) as switching segment and microbial polyester PHBV as crystallizable hard segment were designed as biodegradable shape-memory polymer (SMP) for fast self-expandable stent and synthesized in 96% yield by the reaction of three-arm PCL-triol (M(n) of 4200 g/mol, T(m) of 47 degrees C) with methylene diphenyl 4,4'-diisocyanate isocynate (MDI) to form the hyperbrached MDI-linked PCL (PTCM; M(n) of 25,400 g/mol and a T(m) of 38 degrees C), followed by further polymerization with PHBV-diol (M(n) of 2200 g/mol, T(m) of 137 and 148 degrees C). The polymers were characterized by (1)H NMR, GPC, DSC, tensile test, and cyclic thermomechanical tensile test. PCTBVs showed desired thermal properties, mechanical properties, and ductile nature. PCTBV containing 25 wt% PHBV (PCTBV-25) demonstrated excellent shape-memory property at 40 degrees C, with R(f) of 94%, R(r) of 98%, and shape recovery within 25s. PCTBV-25 was also shown as a safe material with good biocompatibility by cytotoxicity tests and cell growth experiments. The stent made from PCTBV-25 film showed nearly complete self-expansion at 37 degrees C within only 25 s, which is much better and faster than the best known self-expandable stents. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

  3. Ligand Binding Site Detection by Local Structure Alignment and Its Performance Complementarity

    PubMed Central

    Lee, Hui Sun; Im, Wonpil

    2013-01-01

    Accurate determination of potential ligand binding sites (BS) is a key step for protein function characterization and structure-based drug design. Despite promising results of template-based BS prediction methods using global structure alignment (GSA), there is a room to improve the performance by properly incorporating local structure alignment (LSA) because BS are local structures and often similar for proteins with dissimilar global folds. We present a template-based ligand BS prediction method using G-LoSA, our LSA tool. A large benchmark set validation shows that G-LoSA predicts drug-like ligands’ positions in single-chain protein targets more precisely than TM-align, a GSA-based method, while the overall success rate of TM-align is better. G-LoSA is particularly efficient for accurate detection of local structures conserved across proteins with diverse global topologies. Recognizing the performance complementarity of G-LoSA to TM-align and a non-template geometry-based method, fpocket, a robust consensus scoring method, CMCS-BSP (Complementary Methods and Consensus Scoring for ligand Binding Site Prediction), is developed and shows improvement on prediction accuracy. The G-LoSA source code is freely available at http://im.bioinformatics.ku.edu/GLoSA. PMID:23957286

  4. Tyrosine triple mutated AAV2-BDNF gene therapy in a rat model of transient IOP elevation

    PubMed Central

    Igarashi, Tsutomu; Kobayashi, Maika; Kameya, Shuhei; Fujimoto, Chiaki; Nakamoto, Kenji; Takahashi, Hisatomo; Igarashi, Toru; Miyake, Noriko; Iijima, Osamu; Hirai, Yukihiko; Shimada, Takashi; Okada, Takashi; Takahashi, Hiroshi

    2016-01-01

    Purpose We examined the neuroprotective effects of exogenous brain-derived neurotrophic factor (BDNF), which provides protection to retinal ganglion cells (RGCs) in rodents, in a model of transient intraocular pressure (IOP) elevation using a mutant (triple Y-F) self-complementary adeno-associated virus type 2 vector encoding BDNF (tm-scAAV2-BDNF). Methods The tm-scAAV2-BDNF or control vector encoding green fluorescent protein (GFP; tm-scAAV2-GFP) was intravitreally administered to rats, which were then divided into four groups: control, ischemia/reperfusion (I/R) injury only, I/R injury with tm-scAAV2-GFP, and tm-scAAV2-BDNF. I/R injury was then induced by transiently increasing IOP, after which the rats were euthanized to measure the inner retinal thickness and cell counts in the RGC layer. Results Intravitreous injection of tm-scAAV2-BDNF resulted in high levels of BDNF expression in the neural retina. Histological analysis showed that the inner retinal thickness and cell numbers in the RGC layer were preserved after transient IOP elevation in eyes treated with tm-scAAV2-BDNF but not in the other I/R groups. Significantly reduced glial fibrillary acidic protein (GFAP) immunostaining after I/R injury in the rats that received tm-scAAV2-BDNF indicated reduced retinal stress, and electroretinogram (ERG) analysis confirmed preservation of retinal function in the tm-scAAV2-BDNF group. Conclusions These results demonstrate the feasibility and effectiveness of neuroprotective gene therapy using tm-scAAV2-BDNF to protect the inner retina from transiently high intraocular pressure. An in vivo gene therapeutic approach to the clinical management of retinal diseases in conditions such as glaucoma, retinal artery occlusion, hypertensive retinopathy, and diabetic retinopathy thus appears feasible. PMID:27440998

  5. Air Force Manufacturing Technology Electronics Program, FY72-FY85.

    DTIC Science & Technology

    1985-04-01

    magnetic films of the composition Yl.52 EuO.30 TmO.30 CaO.88 Fe4.12 012 on 1.5 inch and 2.0 inch gadolinium gallium garnet substrates. Ten film were...volume manufacturing of hybrid MIC’s. A systematic integrated cost effective approach to testing, trimming/matching, fabri - cation, and assembly is...ESTABLISH MANUFACTURING METHODS FOR LOW COST HIGH RELIABILITY FABRI - CATION AND ACTIVATION OF OXIDE CATHODES FOR USE IN SPACE TRAVELING WAVE TUBES

  6. Expression of caveolin in trabecular meshwork cells and its possible implication in pathogenesis of primary open angle glaucoma

    PubMed Central

    Surgucheva, Irina

    2011-01-01

    Purpose Primary open-angle glaucoma (POAG), which is the most common form of glaucoma, has been associated with a heterogeneous genetic component. A genome-wide association study has identified a common sequence variant at 7q31 (rs4236601 [A]) near the caveolin genes in patients with POAG. Caveolins are a family of integral membrane proteins which participate in many cellular processes, including vesicular transport, cholesterol homeostasis, signal transduction, cell adhesion and migration. The goal of this study was to investigate the expression and regulation of caveolin 1 (CAV-1) and caveolin 2 (CAV-2) in normal and glaucoma trabecular meshwork (TM) cells. Methods CAV-1 and CAV-2 protein expression was quantified by immunoblot analysis using lysates isolated from primary and immortalized TM cells or TM tissue dissected from normal and POAG eyes. The localization of caveolins in TM cells was assessed by immunofluorescent microscopy. CAV-1 and CAV-2 protein expression was also investigated in TM cells at various time points after subjecting the cells to known glaucomatous insults like dexamethasone (DEX) and tumor growth factor beta2 (TGF-β2) treatment. Phosphorylation of CAV-1 at tyrosine 14 in normal and glaucoma TM cell lines was evaluated using a specific monoclonal antibody (Ab). The 5′ upstream region of the CAV-1 gene was amplified and the sequence variant rs4236601 (A/G polymorphic site) and several putative transcription factor-binding sites were modified by in vitro mutagenesis. The effect of nucleotide sequence modifications in the CAV-1 upstream region on gene expression was assayed in a luciferase-based system in TM and non-TM cells. Results CAV-1 and CAV-2 are expressed in TM cells, with localization to the cytoplasm and perinuclear region. DEX increased CAV-1 expression in immortalized glaucoma TM cells by 2.8±0.1 (n=3) fold at 24 h and 2.5±0.1 (n=3) fold at 48 h, compared to 1.3±0.06 (n=3) fold at 24 and 48 h in immortalized normal TM cells. Phosphorylation of CAV-1 at Tyr14 was reduced by 3.2±0.15 (n=3) fold in glaucomatous TM cells when compared to normal TM cells. In POAG and normal TM tissue, CAV-1 expression was found to be uniform. CAV-2, on the other hand, was variable in independent normal and glaucoma TM tissue. Substitution of a G for an A at base pair −2,388 upstream of the start codon of CAV-1, corresponding to the minor allele rs4236601 [A], increased transcriptional activity in TM and non-TM cells when compared to the native sequence. Deletion analysis of putative transcription factor binding sites in the CAV-1 promoter region caused cell-specific effects on gene expression. Conclusions CAV-1 and CAV-2 are expressed in normal and glaucoma tissue and TM cell lines. Phosphorylation of Tyr14 in CAV-1 and transcriptional regulation of CAV-1 expression may have a role in glaucomatous alterations in TM cells. PMID:22128235

  7. VERB [TM] Summer Scorecard: Increasing Tween Girls' Vigorous Physical Activity

    ERIC Educational Resources Information Center

    Alfonso, Moya L.; Thompson, Zachary; McDermott, Robert J.; Colquitt, Gavin; Jones, Jeffery A.; Bryant, Carol A.; Courtney, Anita H.; Davis, Jenna L.; Zhu, Yiliang

    2013-01-01

    Objective: We assessed changes in the frequency of self-reported physical activity (PA) among tween girls exposed and not exposed to the VERB [TM] Summer Scorecard (VSS) intervention in Lexington, Kentucky, during 2004, 2006, and 2007. Methods: Girls who reported 0-1 day per week of PA were classi?ed as having "little or no" PA. Girls…

  8. Comparing Forest/Nonforest Classifications of Landsat TM Imagery for Stratifying FIA Estimates of Forest Land Area

    Treesearch

    Mark D. Nelson; Ronald E. McRoberts; Greg C. Liknes; Geoffrey R. Holden

    2005-01-01

    Landsat Thematic Mapper (TM) satellite imagery and Forest Inventory and Analysis (FIA) plot data were used to construct forest/nonforest maps of Mapping Zone 41, National Land Cover Dataset 2000 (NLCD 2000). Stratification approaches resulting from Maximum Likelihood, Fuzzy Convolution, Logistic Regression, and k-Nearest Neighbors classification/prediction methods were...

  9. A Comparison of Two Methods of Teaching Research to Master of Social Work Students

    ERIC Educational Resources Information Center

    Walsh, Christine Ann; Hewson, Jennifer

    2012-01-01

    While various curriculum strategies have been presented for teaching research, little is known about the effectiveness of different teaching approaches. This study compared two models for teaching research to MSW students: a mentorship model (TM1) and a more structured, didactic model (TM2). Students (n = 23) self-completed the Research Self…

  10. New nanoplatforms based on UCNPs linking with polyhedral oligomeric silsesquioxane (POSS) for multimodal bioimaging

    NASA Astrophysics Data System (ADS)

    Ge, Xiaoqian; Dong, Liang; Sun, Lining; Song, Zhengmei; Wei, Ruoyan; Shi, Liyi; Chen, Haige

    2015-04-01

    A new and facile method was used to transfer upconversion luminescent nanoparticles from hydrophobic to hydrophilic using polyhedral oligomeric silsesquioxane (POSS) linking on the surface of upconversion nanoparticles. In comparison with the unmodified upconversion nanoparticles, the POSS modified upconversion nanoplatforms [POSS-UCNPs(Er), POSS-UCNPs(Tm)] displayed good monodispersion in water and exhibited good water-solubility, while their particle size did not change substantially. Due to the low cytotoxicity and good biocompatibility as determined by methyl thiazolyl tetrazolium (MTT) assay and histology and hematology analysis, the POSS modified upconversion nanoplatforms were successfully applied to upconversion luminescence imaging of living cells in vitro and nude mouse in vivo (upon excitation at 980 nm). In addition, the doped Gd3+ ion endows the POSS-UCNPs with effective T1 signal enhancement and the POSS-UCNPs were successfully applied to in vivo magnetic resonance imaging (MRI) for a Kunming mouse, which makes them potential MRI positive-contrast agents. More importantly, the corner organic groups of POSS can be easily modified, resulting in kinds of POSS-UCNPs with many potential applications. Therefore, the method and results may provide more exciting opportunities for multimodal bioimaging and multifunctional applications.A new and facile method was used to transfer upconversion luminescent nanoparticles from hydrophobic to hydrophilic using polyhedral oligomeric silsesquioxane (POSS) linking on the surface of upconversion nanoparticles. In comparison with the unmodified upconversion nanoparticles, the POSS modified upconversion nanoplatforms [POSS-UCNPs(Er), POSS-UCNPs(Tm)] displayed good monodispersion in water and exhibited good water-solubility, while their particle size did not change substantially. Due to the low cytotoxicity and good biocompatibility as determined by methyl thiazolyl tetrazolium (MTT) assay and histology and hematology analysis, the POSS modified upconversion nanoplatforms were successfully applied to upconversion luminescence imaging of living cells in vitro and nude mouse in vivo (upon excitation at 980 nm). In addition, the doped Gd3+ ion endows the POSS-UCNPs with effective T1 signal enhancement and the POSS-UCNPs were successfully applied to in vivo magnetic resonance imaging (MRI) for a Kunming mouse, which makes them potential MRI positive-contrast agents. More importantly, the corner organic groups of POSS can be easily modified, resulting in kinds of POSS-UCNPs with many potential applications. Therefore, the method and results may provide more exciting opportunities for multimodal bioimaging and multifunctional applications. Electronic supplementary information (ESI) available: Schematic illustration of the formation of POSS-UCNPs. TEM images of NaYF4:Yb,Tm and NaYF4:Yb,Tm@NaGdF4 nanoparticles in cyclohexane; the TEM image of POSS-UCNPs(Tm) in water. DLS of POSS-UCNPs(Tm) in water. The energy dispersive X-ray (EDX) spectrum of POSS-UCNPs(Er). XPS of POSS-UCNPs(Er); XPS of Si element. UCL spectra of POSS-UCNPs(Er) in physiology saline as a function of time. UCL spectra of NaYF4:Yb,Tm@NaGdF4 [UCNPs(Tm)] and POSS-UCNPs(Tm), excited with a 980 nm laser (100 mW cm-2). In vivo UCL imaging of Kunming mice after intravenous injection with POSS-UCNPs(Tm) at different time points. See DOI: 10.1039/c5nr00950b

  11. Pressure buffering by the tympanic membrane. In vivo measurements of middle ear pressure fluctuations during elevator motion.

    PubMed

    Padurariu, Simona; de Greef, Daniël; Jacobsen, Henrik; Nlandu Kamavuako, Ernest; Dirckx, Joris J; Gaihede, Michael

    2016-10-01

    The tympanic membrane (TM) represents a pressure buffer, which contributes to the overall pressure regulation of the middle ear (ME). This buffer capacity is based on its viscoelastic properties combined with those of the attached ossicular chain, muscles and ligaments. The current work presents a set of in vivo recordings of the ME pressure variations normally occurring in common life: elevator motion. This is defined as a situation of smooth ambient pressure increase or decrease on a limited range and at a low rate of pressure change. Based on these recordings, the purpose was a quantitative analysis of the TM buffer capacity including the TM compliance. The pressure changes in seven normal adult ME's with intact TM's were continuously recorded directly inside the ME cavity during four different elevator trips using a high precision instrument. The TM buffer capacity was determined by the ratio between the changes in ME and the ambient pressure. Further, the ME volumes were calculated by Boyle's Law from pressure recordings during inflation-deflation tests; subsequently the TM compliance could also be calculated. Finally, the correlation between the ME volume and buffer function was determined. Twenty-one elevator trips could be used for the analysis. The overall mean TM pressure buffering capacity was 23.3% (SEM = 3.4), whereas the mean overall compliance was 28.9 × 10 -3  μL/Pa (SEM = 4.8). A strong negative linear correlation was found between the TM buffer capacity and the ME volumes (R 2  = 0.92). These results were in fair agreement with the literature obtained in clinical as well as temporal bone experiments, and they provide an in vivo reference for the normal ME function as well as for ME modeling. The TM buffer capacity was found more efficient in smaller mastoids. Possible clinical implications are discussed. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. The effect of spatial, spectral and radiometric factors on classification accuracy using thematic mapper data

    NASA Technical Reports Server (NTRS)

    Wrigley, R. C.; Acevedo, W.; Alexander, D.; Buis, J.; Card, D.

    1984-01-01

    An experiment of a factorial design was conducted to test the effects on classification accuracy of land cover types due to the improved spatial, spectral and radiometric characteristics of the Thematic Mapper (TM) in comparison to the Multispectral Scanner (MSS). High altitude aircraft scanner data from the Airborne Thematic Mapper instrument was acquired over central California in August, 1983 and used to simulate Thematic Mapper data as well as all combinations of the three characteristics for eight data sets in all. Results for the training sites (field center pixels) showed better classification accuracies for MSS spatial resolution, TM spectral bands and TM radiometry in order of importance.

  13. Thematic mapper studies of central Andean volcanoes

    NASA Technical Reports Server (NTRS)

    Francis, Peter W.

    1987-01-01

    A series of false color composite images covering the volcanic cordillera was written. Each image is 45 km (1536 x 1536 pixels) and was constructed using bands 7, 4, and 2 of the Thematic Mapper (TM) data. Approximately 100 images were prepared to date. A set of LANDSAT Multispectral Scanner (MSS) images was used in conjunction with the TM hardcopy to compile a computer data base of all volcanic structure in the Central Andean province. Over 500 individual structures were identified. About 75 major volcanoes were identified as active, or potentially active. A pilot study was begun combining Shuttle Imaging Radar (SIR) data with TM for a test area in north Chile and Bolivia.

  14. Interacting helical surfaces of the transmembrane segments of subunits a and c' of the yeast V-ATPase defined by disulfide-mediated cross-linking.

    PubMed

    Kawasaki-Nishi, Shoko; Nishi, Tsuyoshi; Forgac, Michael

    2003-10-24

    Proton translocation by the vacuolar (H+)-ATPase (or V-ATPase) has been shown by mutagenesis to be dependent upon charged residues present within transmembrane segments of subunit a as well as the three proteolipid subunits (c, c', and c"). Interaction between R735 in TM7 of subunit a and the glutamic acid residue in the middle of TM4 of subunits c and c' or TM2 of subunit c" has been proposed to be essential for proton release to the luminal compartment. In order to determine whether the helical face of TM7 of subunit a containing R735 is capable of interacting with the helical face of TM4 of subunit c' containing the essential glutamic acid residue (Glu-145), cysteine-mediated cross-linking between these subunits in yeast has been performed. Cys-less forms of subunits a and c' as well as forms containing unique cysteine residues were constructed, introduced together into a strain disrupted in both endogenous subunits, and tested for growth at neutral pH, for assembly competence and for cross-linking in the presence of cupric-phenanthroline by SDS-PAGE and Western blot analysis. Four different cysteine mutants of subunit a were each tested pairwise with ten different unique cysteine mutants of subunit c'. Strong cross-linking was observed for the pairs aS728C/c'I142C, aA731C/c'E145C, aA738C/c'F143C, aA738C/c'L147C, and aL739C/c'L147C. Partial cross-linking was observed for an additional 13 of 40 pairs analyzed. When arrayed on a helical wheel diagram, the results suggest that the helical face of TM7 of subunit a containing Arg-735 interacts with the helical face of TM4 of subunit c' centered on Val-146 and bounded by Glu-145 and Leu-147. The results are consistent with a possible rotational flexibility of one or both of these transmembrane segments as well as some flexibility of movement perpendicular to the membrane.

  15. Long-Term Follow-Up of Testicular Microlithiasis in Children and Adolescents: Multicenter Prospective Cohort Study of the Italian Society of Pediatric Urology.

    PubMed

    Marte, Antonio; Pintozzi, Lucia; Cretì, Giuseppe; Chiesa, Pierluigi Lelli; Renzo, Dacia Di; Gasparella, Marco; Maggio, Giovanni Di; Bagnara, Vincenzo; Merlini, Emilio; Tadini, Barbara; Caldarulo, Eustachio; Sangiorgio, Luciano; Battaglino, Gianfranco; Nappo, Simona Gerocarni; Caione, Paolo

    2017-04-01

    Introduction  Testicular microlithiasis (TM), characterized by the presence of intratubular calcifications in a single or both the gonads, is an uncommon entity with unknown etiology and outcome in pediatric and adolescent age. In this study, the results of a multicenter long-term survey are presented. Materials and Methods  From 11 units of pediatric urology/surgery, patients with TM were identified and yearly, followed up in a 7-year period, adopting a specific database. The recorded items were: age at diagnosis, presenting symptoms/associated abnormalities, ultrasonographic finding, surgery and histology at biopsy, if performed. Results  Out of 85 patients, 81 were evaluated yearly (4 patients lost to follow-up). TM was bilateral in 66.6% of the patients. Associate genital abnormalities were present in 90%, more frequently undescended/retractile testis (23.4%) and varicocele (22.2%). TM remained unchanged at 4.7 years follow-up in 77 patients (93.8%) and was reduced in 4 patients after 1 to 5 years of inguinoscrotal surgery. Orchiectomy was performed in three patients (3.7%), one for severe testicular hypoplasia and two for seminoma (2.5%), respectively, concurrent and metachronous to diagnosis of TM. Tumorectomy with parenchymal sparing surgery was performed in a teratoma associated with TM. Conclusion  TM is a controversial entity, often associated with several inguinogenital features, which rarely can recover. Testicular malignancy, although present in TM, has not proven definitively associated to microliths. Proper counseling, yearly ultrasound, and self-examination are long-term recommended. Georg Thieme Verlag KG Stuttgart · New York.

  16. Does Insulin Like Growth Factor-1 (IGF-1) Deficiency Have a "Protective" Role in the Development of Diabetic Retinopathy in Thalassamia Major Patients?

    PubMed

    De Sanctis, Vincenzo; Incorvaia, Carlo; Soliman, Ashraf T; Candini, Giancarlo; Pepe, Alessia; Kattamis, Christos; Soliman, Nada A; Elsedfy, Heba; Kholy, Mohamed El

    2015-01-01

    Both insulin and IGF-1 have been implicated in the control of retinal endothelial cell growth, neovascularization and diabetic retinopathy. Recent findings have established an essential role for IGF-1 in angiogenesis and demonstrated a new target for control of retinopathy that explains why diabetic retinopathy initially increases with the onset of insulin treatment. This cross-sectional study was designed to give insights into relationship between Insulin-Growth-Factor 1 (IGF-1) levels and diabetic retinopathy (DR) in a sample of thalassemia major (TM) patients with insulin dependent diabetes mellitus (IDDM). This relation was not previously evaluated, despite the fact that both diseases co-exist in the same patient. The study also describes the clinical and biochemical profile of the associated complications in TM patients with and without IDDM. A population-based cross-sectional study. The study includes 19 consecutive TM patients with IDDM and 31 age- and sex-matched TM patients without IDDM who visited our out-patient clinics for an endocrine assessment. An extensive medical history, with data on associated complications and current medications, was obtained. Blood samples were drawn in the morning after an overnight fast to measure the serum concentrations of IGF-1, glucose, fructosamine, free thyroxine (FT4), thyrotropin (TSH) and biochemical analysis. Serologic screening assays for hepatitis C virus seropositivity (HCVab and HCV-RNA) were also evaluated; applying routine laboratory methods. Plasma total IGF-1 was measured by a chemiluminescent immunometric assay (CLIA) method. Ophthalmology evaluation was done by the same researcher using stereoscopic fundus biomicroscopy through dilated pupils. DR was graded using the scale developed by the Global Diabetic Retinopathy Group. Iron stores were assessed by direct and indirect methods. Eighteen TM patients with IDDM (94.7 %) and ten non-diabetic patients (32.2 %) had IGF-1 levels below the 2.5(th) percentile of the normal values for the Italian population. The mean serum IGF-1 concentrations were significantly lower in the diabetic versus the non-diabetic TM groups (p < 0.001). DR was present in 4 (21 %) of 19 TM patients with IDDM and was associated with the main classical risk factors, namely inefficient glycemic control and duration of the disease but not hypertension. Using the scale developed by the Global Diabetic Retinopathy Group, the DR in our patients was classified as non proliferative diabetic retinopathy (NPDR). Only a few numbers of microaneurysms [1-3] were detected. Our data also confirm the strong association of IDDM in TM patients with other endocrine and non-endocrine complications.

  17. Cubic to tetragonal phase transition of Tm{sup 3+} doped nanocrystals in oxyfluoride glass ceramics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Yiming; Fu, Yuting; Shi, Yahui

    2016-02-15

    Tm{sup 3+} ions doped β-PbF{sub 2} nanocrystals in oxyfluoride glass ceramics with different doping concentrations and thermal temperatures are prepared by a traditional melt-quenching and thermal treatment method to investigate the structure and the phase transition of Tm{sup 3+} doped nanocrystals. The structures are characterized by X-ray diffraction Rietveld analysis and confirmed with numerical simulation. The phase transitions are proved further by the emission spectra. Both of the doping concentration and thermal temperature can induce an O{sub h} to D{sub 4h} site symmetry distortion and a cubic to tetragonal phase transition. The luminescence of Tm{sup 3+} doped nanocrystals at 800more » nm was modulated by the phase transition of the surrounding crystal field.« less

  18. Analysis of forest disturbance using TM and AVHRR data

    NASA Technical Reports Server (NTRS)

    Spanner, Michael A.; Hlavka, Christine A.; Pierce, Lars L.

    1989-01-01

    A methodology that will be used to determine the proportions of undisturbed, successional vegetation and recently disturbed land cover within coniferous forests using remotely sensed data from the advanced very high resolution radiometer (AVHRR) is presented. The method uses thematic mapper (TM) data to determine the proportions of the three stages of forest disturbance and regrowth for each AVHRR pixel in the sample areas, and is then applied to interpret all AVHRR imagery. Preliminary results indicate that there are predictable relationships between TM spectral response and the disturbance classes. Analysis of ellipse plots from a TM classification of the disturbed forested landscape indicates that the forest classes are separable in the red (0.63-0.69 micron) and near-infrared (0.76-0.90 micron) bands, providing evidence that the proportion of disturbance classes may be determined from AVHRR data.

  19. Experiments and theory for a Tm:Ho:YAG laser end pumped by a Cr:GSAG laser

    NASA Technical Reports Server (NTRS)

    Kim, Kyong H.; Choi, Young S.; Hess, Robert V.; Blair, Clayton H.; Brockman, Philip; Barnes, Norman P.

    1991-01-01

    A Cr:GSAG-laser-pumped Tm:Ho:YAG laser has been fabricated and tested. A maximum output energy of 14 mJ with a slope efficiency of 33.6 percent was obtained using a 98-percent reflective output coupler. A comprehensive rate equation model has been developed to describe laser performance. Details of the experimental measurements and model are presented.

  20. Effects of Making Sense of SCIENCE[TM] Professional Development on the Achievement of Middle School Students, Including English Language Learners. Final Report. NCEE 2012-4002

    ERIC Educational Resources Information Center

    Heller, Joan I.

    2012-01-01

    This study evaluated an approach to professional development for middle school science teachers by closely examining one grade 8 course that embodies that approach. Using a cluster-randomized experimental design, the study tested the effectiveness of the Making Sense of SCIENCE[TM] professional development course on force and motion (Daehler,…

  1. Optical imaging for the diagnosis of oral cancer and oral potentially malignant disorders

    NASA Astrophysics Data System (ADS)

    Yoshida, K.

    2016-03-01

    Optical Imaging is being conducted as a therapeutic non-invasive. Many kinds of the light source are selected for this purpose. Recently the oral cancer screening is conducted by using light-induced tissue autofluorescence examination such as several kinds of handheld devices. However, the mechanism of its action is still not clear. Therefore basic experimental research was conducted. One of auto fluorescence Imaging (AFI) device, VELscopeTM and near-infrared (NIR) fluorescence imaging using ICG-labeled antibody as a probe were compared using oral squamous cell carcinoma (OSCC) mouse models. The experiments revealed that intracutaneous tumor was successfully visualized as low density image by VELscopeTM and high density image by NIR image. In addition, VELscopeTM showed higher sensitivity and lower specificity than that of NIR fluorescence imaging and the sensitivity of identification of carcinoma areas with the VELscopeTM was good results. However, further more studies were needed to enhance the screening and diagnostic uses, sensitivity and specificity for detecting malignant lesions and differentiation from premalignant or benign lesions. Therefore, additional studies were conducted using a new developed near infrared (NIR) fluorescence imaging method targeting podoplanine (PDPN) which consists of indocyanine green (ICG)-labeled anti-human podoplanin antibody as a probe and IVIS imaging system or a handy realtime ICG imaging device that is overexpressed in oral malignant neoplasm to improve imaging for detection of early oral malignant neoplasm. Then evaluated for its sensitivity and specificity for detection of oral malignant neoplasm in xenografted mice model and compared with VELscopeTM. The results revealed that ICG fluorescence imaging method and VELscopeTM had the almost the same sensitivity for detection of oral malignant neoplasm. The current topics of optical imaging about oral malignant neoplasm were reviewed.

  2. Provocation testing to assist craniomandibular pain diagnosis.

    PubMed

    DuPont, John S; Brown, Christopher E

    2010-04-01

    Patients with TMD often present with complex pain symptoms, which can make it difficult to reach a diagnosis. Usually palpation of the masticatory muscles and TM joints, range of motion testing and imaging are used in the diagnostic process. Sometimes it is necessary to evaluate the jaw moving muscles from a functional prospective because they cannot be palpated due to inaccessibility or because they have other structures that are more superficial to them. In these instances, provocation testing can be a helpful adjunct in providing some insight into what is occurring in the area being tested and localizing a suspected source of pain. Anesthesia blocking can be used to confirm any positive findings. This article explores several provocation tests that can be used to evaluate conditions of the masticatory musculature, the TM joints and the stylomandibular ligament.

  3. Spectral characteristics and the extent of paleosols of the Palouse formation

    NASA Technical Reports Server (NTRS)

    Frazier, B. E.; Busacca, Alan; Cheng, Yaan; Wherry, David; Hart, Judy; Gill, Steve

    1988-01-01

    The objective of this study is to test the hypothesis that TM data is adequate in band selection and width and in spatial resolution to distinguish soil organic matter, iron oxide, and lime-silica contents to map several severity classes of erosion in soils of the Palouse region. The methodology used is as follows: (1) To develop spectral relationships from TM data that define the spatial distribution of soil areas by levels of (1) organic matter in the surface soil, (2) iron oxide and clay in exposed paleosol B horizons, and (3) lime-silica accumulations in exposed paleosol B horizons; (2) To compare areas determined by the method outlined in 1 to patterns interpreted from color aerial photos, and to ground observations on bare-soil fields; and (3) To define, on the basis of results of 1 and 2 to the extent possible, where exposed paleosols exist within fields that are not bare, but have a crop cover, and the distribution of desirable and undesirable soil properties in each field.

  4. Post-marketing surveillance data of thrombomodulin alfa: sub-analysis in patients with sepsis-induced disseminated intravascular coagulation.

    PubMed

    Eguchi, Yutaka; Gando, Satoshi; Ishikura, Hiroyasu; Saitoh, Daizoh; Mimuro, Jun; Takahashi, Hoyu; Kitajima, Isao; Tsuji, Hajime; Matsushita, Tadashi; Tsujita, Ryuichi; Nagao, Osamu; Sakata, Yoichi

    2014-01-01

    Thrombomodulin alfa (TM-α, recombinant thrombomodulin) significantly improved disseminated intravascular coagulation (DIC) when compared with heparin therapy in a phase III study. Post-marketing surveillance of TM-α was performed to evaluate the effects and safety in patients with sepsis-induced DIC. From May 2008 to April 2010, a total of 1,787 patients with sepsis-induced DIC treated with TM-α were registered. DIC was diagnosed based on the Japanese Association for Acute Medicine (JAAM) criteria. The DIC resolution and survival rates on day 28 after the last TM-α administration, and changes in DIC, systemic inflammatory response syndrome (SIRS), and sequential organ failure assessment (SOFA) scores and coagulation and inflammation markers were evaluated. The most frequent underlying disease was infectious focus-unknown sepsis (29.8%). The mean ± SD values of age, dose, and the duration of TM-α administration were 64.7 ± 20.3 years, 297.3 ± 111.4 U/kg/day, and 5.6 ± 3.4 days, respectively. A total of 1,320 subjects (73.9%) received combined administration with other anticoagulants. Both coagulation and inflammation markers, such as fibrin/fibrinogen degradation products, prothrombin time ratio, thrombin-antithrombin complex, and C-reactive protein, as well as JAAM DIC, SIRS, and SOFA scores, significantly and simultaneously decreased after TM-α administration (p < 0.001). DIC resolution and 28-day survival rates were 44.4% and 66.0%, respectively. The 28-day survival rate decreased significantly according to the duration of DIC before TM-α administration (p < 0.001). Total adverse drug reactions (ADRs), bleeding ADRs, and serious bleeding adverse events occurred in 126 (7.1%), 98 (5.5%), and 121 (6.8%) subjects, respectively. On day 28, after the last TM-α administration available for an antibody test, only one patient was positive for anti-TM-α antibodies (0.11%). Our results suggest that TM-α is most effective for treating patients with sepsis-induced DIC when administered within the first 3 days after diagnosis.

  5. Biocompatibility evaluation of cigarette and carbon papers used in repair of traumatic tympanic membrane perforations: experimental study.

    PubMed

    Altuntaş, Emine Elif; Sümer, Zeynep

    2013-01-01

    The purposes of this study were to investigate the biocompatibility of two different paper patches (carbon and cigarette papers) and compare the adhesion and proliferation features of L929 fibroblast cells by using 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide (MTT Test) test and scanning electron microscopy (SEM). In this study, time-dependent cytotoxic effects of cigarette and carbon papers used in repairing small traumatic TM perforations were investigated in vitro by using MTT test. And also adhesion and spreading of cells over disk surface were observed by SEM. Cytotoxicity test carried out by MTT analysis on leakage products collected from two types of paper patches at the end of 24 and 48 h revealed no cytotoxicity (P > 0.05). In SEM studies, it was observed that cells started to proliferate over disk surface as a result of 48-h incubation, and SEM revealed that the cell proliferation over cigarette paper was more compared to the one over carbon paper. We believe that this is the first study where biocompatibility and adhesion features of carbon and cigarette paper have been studied by using L929 fibroblast cell culture. As a result, biocompatibility of cigarette paper and also whether cigarette paper was superior to carbon paper in cell attachment and biocompatibility were studied. It was found, by MTT test and SEM test, that cigarette paper had a higher biocompatibility and cell attachment, and thus cigarette paper should be the patch to be preferred in cases where TM perforations are repaired by paper-patch method.

  6. Systematic autistic-like behavioral phenotyping of 4 mouse strains using a novel wheel-running assay.

    PubMed

    Karvat, Golan; Kimchi, Tali

    2012-08-01

    Three core symptoms of autistic spectrum disorders are stereotypic movements, resistance to change in routines and deficits in social interaction. In order to understand their neuronal mechanisms, there is a dire need for behavioral paradigms to assess those symptoms in rodents. Here we present a novel method which is based on positive reward in a customized wheel-running apparatus to assess these symptoms. As a proof of concept, 4 mouse strains were tested in the new behavioral paradigm; 2 control lines (C57BL/6 and ICR) and 2 mouse-models of autism (BTBR T+ tf/J and Nlgn3(tm1Sud)). We found that the C57BL/6, ICR and Nlgn3(tm1Sud) mice showed a significant reduction in stereotypical behavior in the presence of the running wheel, ability to forfeit the running habit when the running-wheel was jammed, and preference of interacting with a social stimulus over the jammed running-wheel. No difference was found between genotypes of the Nlgn3(tm1Sud) mice. On the other hand, the BTBR mice exhibited persistent, elevated levels of stereotypical behavior. In addition, they presented a deficit in their ability to adjust to a changing environment, as manifested in persistence to interact with the wheel even when it was jammed. Lastly, the BTBR mice exhibited no significant preference to interact with the stranger mouse over the jammed running-wheel. These results were validated by a set of commonly used behavioral tests. Overall, our novel behavioral paradigm detects multiple components of autistic-like phenotypes, including cognitive rigidity, stereotypic behavior and social deficiency. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Evaluation of cytotoxicity and corrosion resistance of orthodontic mini-implants.

    PubMed

    Alves, Celha Borges Costa; Segurado, Márcio Nunes; Dorta, Miriam Cristina Leandro; Dias, Fátima Ribeiro; Lenza, Maurício Guilherme; Lenza, Marcos Augusto

    2016-01-01

    To evaluate and compare in vitro cytotoxicity and corrosion resistance of mini-implants from three different commercial brands used for orthodontic anchorage. Six mini-implants (Conexão(tm), Neodent(tm) and SIN(tm)) were separately immersed in artificial saliva (pH 6.76) for 30 and 60 days. The cytotoxicity of the corrosion extracts was assessed in L929 cell cultures using the violet crystal and MTT assays, as well as cell morphology under light microscopy. Metal surface characteristics before and after immersion in artificial saliva were assessed by means of scanning electron microscopy (SEM). The samples underwent atomic absorption spectrophotometry to determine the concentrations of aluminum and vanadium ions, constituent elements of the alloy that present potential toxicity. For statistical analysis, one-way ANOVA/Bonferroni tests were used for comparisons among groups with p < 0.05 considered significant. Statistical analysis was carried out with Graph Pad PRISM software Version 4.0. No changes in cell viability or morphology were observed. Mini-implants SEM images revealed smooth surfaces with no obvious traces of corrosion. The extracts assessed by means of atomic absorption spectrophotometry presented concentrations of aluminum and vanadium ions below 1.0 µg/mL and 0.5 µg/mL, respectively. Orthodontic mini-implants manufactured by Conexão(tm), Neodent(tm) and SIN(tm) present high corrosion resistance and are not cytotoxic.

  8. Satellite inventory of Minnesota forest resources

    NASA Technical Reports Server (NTRS)

    Bauer, Marvin E.; Burk, Thomas E.; Ek, Alan R.; Coppin, Pol R.; Lime, Stephen D.; Walsh, Terese A.; Walters, David K.; Befort, William; Heinzen, David F.

    1993-01-01

    The methods and results of using Landsat Thematic Mapper (TM) data to classify and estimate the acreage of forest covertypes in northeastern Minnesota are described. Portions of six TM scenes covering five counties with a total area of 14,679 square miles were classified into six forest and five nonforest classes. The approach involved the integration of cluster sampling, image processing, and estimation. Using cluster sampling, 343 plots, each 88 acres in size, were photo interpreted and field mapped as a source of reference data for classifier training and calibration of the TM data classifications. Classification accuracies of up to 75 percent were achieved; most misclassification was between similar or related classes. An inverse method of calibration, based on the error rates obtained from the classifications of the cluster plots, was used to adjust the classification class proportions for classification errors. The resulting area estimates for total forest land in the five-county area were within 3 percent of the estimate made independently by the USDA Forest Service. Area estimates for conifer and hardwood forest types were within 0.8 and 6.0 percent respectively, of the Forest Service estimates. A trial of a second method of estimating the same classes as the Forest Service resulted in standard errors of 0.002 to 0.015. A study of the use of multidate TM data for change detection showed that forest canopy depletion, canopy increment, and no change could be identified with greater than 90 percent accuracy. The project results have been the basis for the Minnesota Department of Natural Resources and the Forest Service to define and begin to implement an annual system of forest inventory which utilizes Landsat TM data to detect changes in forest cover.

  9. Single-Use Poly(etheretherketone) Solid-Phase Microextraction-Transmission Mode Devices for Rapid Screening and Quantitation of Drugs of Abuse in Oral Fluid and Urine via Direct Analysis in Real-Time Tandem Mass Spectrometry.

    PubMed

    Vasiljevic, Tijana; Gómez-Ríos, Germán Augusto; Pawliszyn, Janusz

    2018-01-02

    The analysis of oral fluid (OF) and urine samples to detect drug consumption has garnered considerable attention as alternative biomatrices. Efficient implementation of microextraction and ambient ionization technologies for rapid detection of target compounds in such biomatrices creates a need for biocompatible devices which can be implemented for in vivo sampling and easily interfaced with mass spectrometry (MS) analyzers. This study introduces a novel solid-phase microextraction-transmission mode (SPME-TM) device made of poly(etheretherketone) (PEEK) mesh that can rapidly detect prohibited substances in biofluids via direct analysis in real-time tandem MS (DART-MS/MS). PEEK mesh was selected due to its biocompatibility, excellent resistance to various organic solvents, and its ability to withstand relatively high temperatures (≤350 °C). The meshes were coated with hydrophilic-lipophilic-balance particle-poly(acrylonitrile) (HLB-PAN) slurry. The robustness of the coated meshes was tested by performing rapid vortex agitation (≥3200 rpm) in LC/MS-grade solvents and by exposing them to the DART source jet stream at typical operational temperatures (∼250-350 °C). PEEK SPME-TM devices proved to be robust and were therefore used to perform ex vivo analysis of drugs of abuse spiked in urine and OF samples. Excellent results were obtained for all analytes under study; furthermore, the tests yielded satisfactory limits of quantitation (median, ∼0.5 ng mL -1 ), linearity (≥0.99), and accuracy (80-120%) over the evaluated range (0.5-200 ng mL -1 ). This research highlights plastic SPME-TM's potential usefulness as a method for rapidly screening for prohibited substances in on-site/in vivo scenarios, such as roadside or workplace drug testing, antidoping controls, and pain management programs.

  10. Using the Sonoran Desert test site to monitor the long-term radiometric stability of the Landsat TM/ETM+ and Terra MODIS sensors

    USGS Publications Warehouse

    Angal, A.; Xiong, X.; Choi, T.; Chander, G.; Wu, A.

    2009-01-01

    Pseudo-invariant ground targets have been extensively used to monitor the long-term radiometric calibration stability of remote sensing instruments. The NASA MODIS Characterization Support Team (MCST), in collaboration with members from the U.S. Geological Survey (USGS) Earth Resources Observation and Science (EROS) Center, has previously demonstrated the use of pseudo-invariant ground sites for the long-term stability monitoring of Terra MODIS and Landsat 7 ETM+ sensors. This paper focuses on the results derived from observations made over the Sonoran Desert. Additionally, Landsat 5 TM data over the Sonoran Desert site were used to evaluate the temporal stability of this site. Top-ofatmosphere (TOA) reflectances were computed for the closely matched TM, ETM+, and MODIS spectral bands over selected regions of interest. The impacts due to different viewing geometries, or the effect of test site Bi-directional Reflectance Distribution Function (BRDF), are also presented. ?? 2009 SPIE.

  11. Does the use of Nintendo Wii SportsTM improve arm function? Trial of WiiTM in Stroke: a randomized controlled trial and economics analysis.

    PubMed

    Adie, Katja; Schofield, Christine; Berrow, Margie; Wingham, Jennifer; Humfryes, John; Pritchard, Colin; James, Martin; Allison, Rhoda

    2017-02-01

    The Trial of Wii™ in Stroke investigated the efficacy of using the Nintendo Wii Sports™ (Wii TM ) to improve affected arm function after stroke. Multicentre, pragmatic, parallel group, randomized controlled trial. Home-based rehabilitation. A total of 240 participants aged 24-90 years with arm weakness following a stroke within the previous six months. Participants were randomly assigned to exercise daily for six weeks using the Wii TM or arm exercises at home. Primary outcome was change in the affected arm function at six weeks follow-up using the Action Research Arm Test. Secondary outcomes included occupational performance, quality of life, arm function at six months and a cost effectiveness analysis. The study was completed by 209 participants (87.1%). There was no significant difference in the primary outcome of affected arm function at six weeks follow-up (mean difference -1.7, 95% CI -3.9 to 0.5, p = 0.12) and no significant difference in secondary outcomes, including occupational performance, quality of life or arm function at six months, between the two groups. No serious adverse events related to the study treatment were reported. The cost effectiveness analysis showed that the Wii TM was more expensive than arm exercises £1106 (SD 1656) vs. £730 (SD 829) (probability 0.866). The trial showed that the Wii TM was not superior to arm exercises in home-based rehabilitation for stroke survivors with arm weakness. The Wii TM was well tolerated but more expensive than arm exercises.

  12. Molecular insights into the m-AAA protease-mediated dislocation of transmembrane helices in the mitochondrial inner membrane.

    PubMed

    Lee, Seoeun; Lee, Hunsang; Yoo, Suji; Kim, Hyun

    2017-12-08

    Protein complexes involved in respiration, ATP synthesis, and protein import reside in the mitochondrial inner membrane; thus, proper regulation of these proteins is essential for cell viability. The m -AAA protease, a conserved hetero-hexameric AAA (ATPase associated with diverse cellular activities) protease, composed of the Yta10 and Yta12 proteins, regulates mitochondrial proteostasis by mediating protein maturation and degradation. It also recognizes and mediates the dislocation of membrane-embedded substrates, including foreign transmembrane (TM) segments, but the molecular mechanism involved in these processes remains elusive. This study investigated the role of the TM domains in the m -AAA protease by systematic replacement of one TM domain at a time in yeast. Our data indicated that replacement of the Yta10 TM2 domain abolishes membrane dislocation for only a subset of substrates, whereas replacement of the Yta12 TM2 domain impairs membrane dislocation for all tested substrates, suggesting different roles of the TM domains in each m -AAA protease subunit. Furthermore, m -AAA protease-mediated membrane dislocation was impaired in the presence of a large downstream hydrophilic moiety in a membrane substrate. This finding suggested that the m -AAA protease cannot dislocate large hydrophilic domains across the membrane, indicating that the membrane dislocation probably occurs in a lipid environment. In summary, this study highlights previously underappreciated biological roles of TM domains of the m -AAA proteases in mediating the recognition and dislocation of membrane-embedded substrates. © 2017 by The American Society for Biochemistry and Molecular Biology, Inc.

  13. Characterizing fire-related spatial patterns in fire-prone ecosystems using optical and microwave remote sensing

    NASA Astrophysics Data System (ADS)

    Henry, Mary Catherine

    The use of active and passive remote sensing systems for relating forest spatial patterns to fire history was tested over one of the Arizona Sky Islands. Using Landsat Thematic Mapper (TM), Shuttle Imaging Radar (SIR-C), and data fusion I examined the relationship between landscape metrics and a range of fire history characteristics. Each data type (TM, SIR-C, and fused) was processed in the following manner: each band, channel, or derived feature was simplified to a thematic layer and landscape statistics were calculated for plots with known fire history. These landscape metrics were then correlated with fire history characteristics, including number of fire-free years in a given time period, mean fire-free interval, and time since fire. Results from all three case studies showed significant relationships between fire history and forest spatial patterns. Data fusion performed as well or better than Landsat TM alone, and better than SIR-C alone. These comparisons were based on number and strength of significant correlations each method achieved. The landscape metric that was most consistent and obtained the greatest number of significant correlations was Shannon's Diversity Index. Results also agreed with field-based research that has linked higher fire frequency to increased landscape diversity and patchiness. An additional finding was that the fused data seem to detect fire-related spatial patterns over a range of scales.

  14. Optical Analysis of Transparent Polymeric Material Exposed to Simulated Space Environment

    NASA Technical Reports Server (NTRS)

    Edwards, David L.; Finckenor, Miria M.

    1999-01-01

    Transparent polymeric materials are being designed and utilized as solar concentrating lenses for spacecraft power and propulsion systems. These polymeric lenses concentrate solar energy onto energy conversion devices such as solar cells and thermal energy systems. The conversion efficiency is directly related to the transmissivity of the polymeric lens. The Environmental Effects Group of the Marshall Space Flight Center's Materials, Processes, and Manufacturing Department exposed a variety of materials to a simulated space environment and evaluated them for an, change in optical transmission. These materials include Lexan(TM), polyethylene terephthalate (PET). several formulations of Tefzel(TM). and Teflon(TM), and silicone DC 93-500. Samples were exposed to a minimum of 1000 Equivalent Sun Hours (ESH) of near-UV radiation (250 - 400 nm wavelength). Data will be presented on materials exposed to charged particle radiation equivalent to a five-year dose in geosynchronous orbit. These exposures were performed in MSFC's Combined Environmental Effects Test Chamber, a unique facility with the capability to expose materials simultaneously or sequentially to protons, low-energy electrons, high-energy electrons, near UV radiation and vacuum UV radiation.Prolonged exposure to the space environment will decrease the polymer film's transmission and thus reduce the conversion efficiency. A method was developed to normalize the transmission loss and thus rank the materials according to their tolerance to space environmental exposure. Spectral results and the material ranking according to transmission loss are presented.

  15. A compact structured light based otoscope for three dimensional imaging of the tympanic membrane

    NASA Astrophysics Data System (ADS)

    Das, Anshuman J.; Estrada, Julio C.; Ge, Zhifei; Dolcetti, Sara; Chen, Deborah; Raskar, Ramesh

    2015-02-01

    Three dimensional (3D) imaging of the tympanic membrane (TM) has been carried out using a traditional otoscope equipped with a high-definition webcam, a portable projector and a telecentric optical system. The device allows us to project fringe patterns on the TM and the magnified image is processed using phase shifting algorithms to arrive at a 3D description of the TM. Obtaining a 3D image of the TM can aid in the diagnosis of ear infections such as otitis media with effusion, which is essentially fluid build-up in the middle ear. The high resolution of this device makes it possible examine a computer generated 3D profile for abnormalities in the shape of the eardrum. This adds an additional dimension to the image that can be obtained from a traditional otoscope by allowing visualization of the TM from different perspectives. In this paper, we present the design and construction of this device and details of the imaging processing for recovering the 3D profile of the subject under test. The design of the otoscope is similar to that of the traditional device making it ergonomically compatible and easy to adopt in clinical practice.

  16. Shape and 3D acoustically induced vibrations of the human eardrum characterized by digital holography

    NASA Astrophysics Data System (ADS)

    Khaleghi, Morteza; Furlong, Cosme; Cheng, Jeffrey Tao; Rosowski, John J.

    2014-07-01

    The eardrum or Tympanic Membrane (TM) transfers acoustic energy from the ear canal (at the external ear) into mechanical motions of the ossicles (at the middle ear). The acousto-mechanical-transformer behavior of the TM is determined by its shape and mechanical properties. For a better understanding of hearing mysteries, full-field-of-view techniques are required to quantify shape, nanometer-scale sound-induced displacement, and mechanical properties of the TM in 3D. In this paper, full-field-of-view, three-dimensional shape and sound-induced displacement of the surface of the TM are obtained by the methods of multiple wavelengths and multiple sensitivity vectors with lensless digital holography. Using our developed digital holographic systems, unique 3D information such as, shape (with micrometer resolution), 3D acoustically-induced displacement (with nanometer resolution), full strain tensor (with nano-strain resolution), 3D phase of motion, and 3D directional cosines of the displacement vectors can be obtained in full-field-ofview with a spatial resolution of about 3 million points on the surface of the TM and a temporal resolution of 15 Hz.

  17. Evaluating the potential of Landsat TM/ETM+ imagery for assessing fire severity in Alaskan black spruce forests

    Treesearch

    Elizabeth E. Hoy; Nancy H.F. French; Merritt R. Turetsky; Simon N. Trigg; Eric S. Kasischke

    2008-01-01

    Satellite remotely sensed data of fire disturbance offers important information; however, current methods to study fire severity may need modifications for boreal regions. We assessed the potential of the differenced Normalized Burn Ratio (dNBR) and other spectroscopic indices and image transforms derived from Landsat TM/ETM+ data for mapping fire severity in Alaskan...

  18. Teaching Healthful Food Choices to Elementary School Students and Their Parents: The Nutrition Detectives[TM] Program

    ERIC Educational Resources Information Center

    Katz, David L.; Katz, Catherine S.; Treu, Judith A.; Reynolds, Jesse; Njike, Valentine; Walker, Jennifer; Smith, Erica; Michael, Jennifer

    2011-01-01

    Background: The purpose of this study was to evaluate the effects of a nutrition education program designed to teach elementary school students and their parents, and to distinguish between more healthful and less healthful choices in diverse food categories. Methods: Three schools were assigned to receive the Nutrition Detectives[TM] program and…

  19. Information theoretic comparisons of original and transformed data from Landsat MSS and TM

    NASA Technical Reports Server (NTRS)

    Malila, W. A.

    1985-01-01

    The dispersion and concentration of signal values in transformed data from the Landsat-4 MSS and TM instruments are analyzed using a communications theory approach. The definition of entropy of Shannon was used to quantify information, and the concept of mutual information was employed to develop a measure of information contained in several subsets of variables. Several comparisons of information content are made on the basis of the information content measure, including: system design capacities; data volume occupied by agricultural data; and the information content of original bands and Tasseled Cap variables. A method for analyzing noise effects in MSS and TM data is proposed.

  20. Optical spectroscopy and diode-pumped laser characteristics of codoped Tm-Ho:YLF and Tm-Ho:BaYF: a comparative analysis

    NASA Astrophysics Data System (ADS)

    Cornacchia, F.; Sani, E.; Toncelli, A.; Tonelli, M.; Marano, M.; Taccheo, S.; Galzerano, G.; Laporta, P.

    Single crystals of monoclinic BaY2F8 and tetragonal LiYF4 codoped with the same Tm3+ and Ho3+ concentrations were successfully grown by the Czochralski method. Here we present a comparative analysis of the two hosts including spectroscopic characterization and cw diode-pumped laser experiments in the 2-μm wavelength region at room temperature. The main differences between the two hosts are a lower slope efficiency associated with a much wider tuning range (2005-2094 nm) of BaY2F8 with respect to LiYF4.

  1. Laser Doppler Vibrometry measurements of human cadaveric tympanic membrane vibration

    PubMed Central

    2013-01-01

    Objective To determine the feasibility of measuring tympanic membrane (TM) vibrations at multiple locations on the TM to differentiate normal eardrums from those with associated ossicular pathologies. Design Cadaveric human temporal bone study. Setting Basic science laboratory. Methods A mastoidectomy and facial recess approach was performed on four cadaveric temporal bones to obtain access to the ossicles without disrupting the TM. Ossicles were palpated to ensure normal mobility and an intact ossicular chain. Laser Doppler Vibrometry (LDV) measurements were then taken on all four TMs. LDV measurements were repeated on each TM following stapes footplate fixation, incudo-stapedial joint dislocation, and malleus head fixation. Main outcome measures LDV measurements of TM vibration at the umbo, the lateral process of the malleus, and in each of the four quadrants of the TM. Results The best signal-to-noise ratios were found between 2 and 4 kHz, at the umbo, the anterior superior quadrant, the anterior inferior quadrant, and the posterior inferior quadrant. Since our goal was to assess the ossicular chain, we selected the TM locations closest to the ossicular chain (the umbo and lateral process of the malleus) for further analysis. Differences could be seen between normals and the simulated ossicular pathologies, but values were not statistically significant. Conclusions LDV measurements are technically challenging and require optimization to obtain consistent measurements. This study demonstrates the potential of LDV to differentiate ossicular pathologies behind an intact tympanic membrane. Future studies will further characterize the clinical role of this diagnostic modality. PMID:23663748

  2. Radial vorticity constraint in core flow modeling

    NASA Astrophysics Data System (ADS)

    Asari, S.; Lesur, V.

    2011-11-01

    We present a new method for estimating core surface flows by relaxing the tangentially geostrophic (TG) constraint. Ageostrophic flows are allowed if they are consistent with the radial component of the vorticity equation under assumptions of the magnetostrophic force balance and an insulating mantle. We thus derive a tangentially magnetostrophic (TM) constraint for flows in the spherical harmonic domain and implement it in a least squares inversion of GRIMM-2, a recently proposed core field model, for temporally continuous core flow models (2000.0-2010.0). Comparing the flows calculated using the TG and TM constraints, we show that the number of degrees of freedom for the poloidal flows is notably increased by admitting ageostrophic flows compatible with the TM constraint. We find a significantly improved fit to the GRIMM-2 secular variation (SV) by including zonal poloidal flow in TM flow models. Correlations between the predicted and observed length-of-day variations are equally good under the TG and TM constraints. In addition, we estimate flow models by imposing the TM constraint together with other dynamical constraints: either purely toroidal (PT) flow or helical flow constraint. For the PT case we cannot find any flow which explains the observed SV, while for the helical case the SV can be fitted. The poor compatibility between the TM and PT constraints seems to arise from the absence of zonal poloidal flows. The PT flow assumption is likely to be negated when the radial magnetostrophic vorticity balance is taken into account, even if otherwise consistent with magnetic observations.

  3. A new comprehensive index for drought monitoring with TM data

    NASA Astrophysics Data System (ADS)

    Wang, Yuanyuan

    2017-10-01

    Drought is one of the most important and frequent natural hazards to agriculture production in North China Plain. To improve agriculture water management, accurate drought monitoring information is needed. This study proposed a method for comprehensive drought monitoring by combining a meteorological index and three satellite drought indices of TM data together. SPI (Standard Precipitation Index), the meteorological drought index, is used to measure precipitation deficiency. Three satellite drought indices (Temperature Vegetation Drought Index, Land Surface Water Index, Modified Perpendicular Drought Index) are used to evaluate agricultural drought risk by exploring data from various channels (VIS, NIR, SWIR, TIR). Considering disparities in data ranges of different drought indices, normalization is implemented before combination. First, SPI is normalized to 0 — 100 given that its normal range is -4 - +4. Then, the three satellite drought indices are normalized to 0 - 100 according to the maximum and minimum values in the image, and aggregated using weighted average method (the result is denoted as ADI, Aggregated drought index). Finally, weighed geometric mean of SPI and ADI are calculated (the result is denoted as DIcombined). A case study in North China plain using three TM images acquired during April-May 2007 show that the method proposed in this study is effective. In spatial domain, DIcombined demonstrates dramatically more details than SPI; in temporal domain, DIcombined shows more reasonable drought development trajectory than satellite indices that are derived from independent TM images.

  4. Systematic Investigations of Biomimetic Catalysts in the Synthesis of Reactive Metal Oxide Nanoparticle Networks

    DTIC Science & Technology

    2012-09-01

    dioxide and aluminum oxide. Numerous polymeric templates (Table 1), such as polyallyamine (PAA), were investigated, along with amine- functionalized ...SephadexTM LH60 (an anionic functionalized resin) and SephadexTM G-100 (unfunctionalized) were used as the functionalized surface. The reaction conditions...formed with all of the polymers tested and from some of the functionalized surface. SEM images (Figure 1) show that with the exception of the

  5. Comparison of Measured vs Modeled TE and TM Field Penetration into a Slotted Circular Cylinder

    DTIC Science & Technology

    2011-01-01

    1. INTRODUCTION In the testing of military systems and subsystems for electromag- netic vulnerability (EMV) and hazards of electromagnetic radiation ...to ordnance ( HERO ), extremely high amplitude (peak and rms) elec- tromagnetic fields must be generated and radiated to immerse the sys- tem/subsystem...Progress In Electromagnetics Research B, Vol. 28, 201–218, 2011 COMPARISON OF MEASURED VS. MODELED TE AND TM FIELD PENETRATION INTO A SLOTTED

  6. Obstacles in Using Randomization Tests in Single-Case Experimentation.

    ERIC Educational Resources Information Center

    Kazdin, Alan E.

    1980-01-01

    Problems associated with randomization tests in single- case experiments are discussed. This article follows a discussion of randomization tests in single case studies in the same issue of this journal. (See TM 505 799; 505 801).(Author/JKS)

  7. Optical thermometry using fluorescence intensities multi-ratios in NaGdTiO4:Yb3+/Tm3+ phosphors

    NASA Astrophysics Data System (ADS)

    Zhou, Aihua; Song, Feng; Song, Feifei; Feng, Ming; Adnan, Khan; Ju, Dandan; Wang, Xueqing

    2018-04-01

    The NaGdTiO4:Yb3+/Tm3+ phosphor has been effectively synthesized by the traditional solid-state reaction method and its down-conversion and up-conversion luminescence properties were systematically studied. The results indicate that the electric dipole-dipole interaction is the main mechanism for the luminescence quenching. The fact that the ratios of the up-conversion intensities, i.e., I795nm/I798nm, I807nm/I798nm, and I812nm/I798nm, increase linearly with temperature (100 K-300 K) provides us a simple and accurate temperature measurement method. Multi-ratios can be more accurate than using only one ratio, allowing for self-referenced temperature determination. It's promising for NaGdTiO4: Yb3+/Tm3+ to be used for optical temperature sensors.

  8. Methods for the culture of C. elegans and S. cerevisiae in microgravity

    NASA Technical Reports Server (NTRS)

    Fahlen, Thomas; Sunga, June; Rask, Jon; Herrera, Anna; Lam, Kitty; Sing, Luke; Sato, Kevin; Ramos, Ross A.; Kirven-Brooks, Melissa; Reiss-Bubenheim, Debra

    2005-01-01

    To support the study of the effects of microgravity on biological systems, our group is developing and testing methods that allow the cultivation of C. elegans and S. cerevisiae in microgravity. Our aim is to develop the experimental means by which investigators may conduct peer reviewed biological experiments with C. elegans or S. cerevisiae in microgravity. Our protocols are aimed at enabling investigators to grow these organisms for extended periods during which samples may be sub-cultured, collected, preserved, frozen, and/or returned to earth for analysis. Data presented include characterization of the growth phenotype of these organisms in liquid medium in OptiCells(TM) (Biocrystal, LTD).

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luczkovich, J.J.; Wagner, T.W.; Michalek, J.L.

    In order to monitor changes caused by local and global human actions to a coral reef ecosystem, we sea-truthed a natural color Landsat TM image prepared for a coastal region of the northwestern Dominican Republic and recorded average water depth, precise geographical positions, and bottom types (seagrass, 15 sites; coral reef, ten sites; and sand, six sites). There were no significant differences in depth for the bottom type groups. The depths ranged from 0 to 16.1 m. Mean digital counts of seagrass and coral reef sites did not differ significantly in any band. A multivariate analysis of variance using allmore » three bands gave similar results. A ratio of the green/blue bands (TM 2/TM 1) showed there was a spectral shift associated with increasing depth, but not bottom type. Due to small-scale patchiness, seagrass and coral areas were difficult to distinguish, but sandy areas can be distinguished using Landsat TM imagery and our methods. 12 refs.« less

  10. Assessment of Thematic Mapper band-to-band registration by the block correlation method

    NASA Technical Reports Server (NTRS)

    Card, D. H.; Wrigley, R. C.; Mertz, F. C.; Hall, J. R.

    1983-01-01

    Rectangular blocks of pixels from one band image were statistically correlated against blocks centered on identical pixels from a second band image. The block pairs were shifted in pixel increments both vertically and horizontally with respect to each other and the correlation coefficient to the maximum correlation was taken as the best estimate of registration error for each block pair. For the band combinations of the Arkansas scene studied, the misregistration of TM spectral bands within the noncooled focal plane lie well within the 0.2 pixel target specification. Misregistration between the middle IR bands is well within this specification also. The thermal IR band has an apparent misregistration with TM band 7 of approximately 3 pixels in each direction. The TM band 3 has a misregistration of approximately 0.2 pixel in the across-scan direction and 0.5 pixel in the along-scan direction, with both TM bands 5 and 7.

  11. Assessment of Thematic Mapper Band-to-band Registration by the Block Correlation Method

    NASA Technical Reports Server (NTRS)

    Card, D. H.; Wrigley, R. C.; Mertz, F. C.; Hall, J. R.

    1985-01-01

    Rectangular blocks of pixels from one band image were statistically correlated against blocks centered on identical pixels from a second band image. The block pairs were shifted in pixel increments both vertically and horizontally with respect to each other and the correlation coefficient to the maximum correlation was taken as the best estimate of registration error for each block pair. For the band combinations of the Arkansas scene studied, the misregistration of TM spectral bands within the noncooled focal plane lie well within the 0.2 pixel target specification. Misregistration between the middle IR bands is well within this specification also. The thermal IR band has an apparent misregistration with TM band 7 of approximately 3 pixels in each direction. The TM band 3 has a misregistration of approximately 0.2 pixel in the across-scan direction and 0.5 pixel in the along-scan direction, with both TM bands 5 and 7.

  12. False positives in Biolog EcoPlates™ and MT2 MicroPlates™ caused by calcium.

    PubMed

    Pierce, Melissa L; Ward, J Evan; Dobbs, Fred C

    2014-02-01

    Biolog MicroPlates(TM) (e.g. EcoPlate(TM), MT2 MicroPlate(TM), GN MicroPlate(TM)) are useful tools for characterizing microbial communities, providing community-level physiological profiles to terrestrial and aquatic ecologists. The more recently designed Biolog EcoPlates have been used frequently in aquatic ecology with success. This study, however, reveals one major problem when using EcoPlates to evaluate samples within an estuarine or seawater matrix. At concentrations greater than 100 parts per million, the cation calcium begins to interfere with the microplate chemistry, causing false positive readings. Experiments, in which multiple treatments of natural and artificial seawater were tested, as well as calcium-addition experiments, demonstrate that calcium inhibits complete dissolution of the minimal growth medium in wells. Future studies involving Biolog EcoPlates and MicroPlates should take this effect into account, and the dilution of samples is strongly recommended to diminish the "calcium effect." Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Analysis of Samples Collected from the Surface of Interim Storage Canisters at Calvert Cliffs in June 2017: Revision 01.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bryan, Charles R.; Schindelholz, Eric John

    In June 2017, dust and salt samples were collected from the surface of Spent Nuclear Fuel (SNF) dry storage canisters at the Calvert Cliffs Nuclear Power Plant. The samples were delivered to Sandia National laboratories for analysis. Two types of samples were collected: filter-backed Scotch-Brite TM pads were used to collect dry dust samples for characterization of salt and dust morphologies and distributions; and Saltsmart TM test strips were used to collect soluble salts for determining salt surface loadings per unit area. After collection, the samples were sealed into plastic sleeves for shipping. Condensation within the sleeves containing the Scotch-Britemore » TM samples remobilized the salts, rendering them ineffective for the intended purpose, and also led to mold growth, further compromising the samples; for these reasons, the samples were not analyzed. The SaltSmart TM samples were unaffected and were analyzed by ion chromatography for major anions and cations. The results of those analyses are presented here.« less

  14. Eclipse SteerTech liquid lenslet beam steering technology

    NASA Astrophysics Data System (ADS)

    Westfall, Raymond T.; Rogers, Stanley; Shannon, Kenneth C., III

    2007-09-01

    Eclipse SteerTech TM transmissive fluid state electrowetting technology has successfully demonstrated the ability to control the shape and position of a fluid lenslet. In its final form, the technology will incorporate a dual fluid lenslet approach capable of operating in extremely high acceleration environments. The beam steering system works on the principle of electro-wetting. A substrate is covered with a closely spaced array of, independently addressable, transparent, electrically conductive pixels utilizing Eclipse's proprietary EclipseTEC TM technology. By activating and deactivating selected EclipseTEC TM pixels in the proper sequence, the shape and position of fluid lenslets or arrays of lenslets can be dynamically changed at will. The position and shape of individual fluid lenslets may be accurately controlled on any flat, simply curved, or complex curved, transparent or reflective surface. The smaller the pixels the better control of the position and shape of the fluid lenslets. Information on the successful testing of the Eclipse SteerTech TM lenslet and discussion of its use in a de-centered lenslet array will be presented.

  15. Study of LANDSAT-D thematic mapper performance as applied to hydrocarbon exploration

    NASA Technical Reports Server (NTRS)

    Everett, J. R. (Principal Investigator)

    1983-01-01

    Two fully processed test tapes were enhanced and evaluated at scales up to 1:10,000, using both hardcopy output and interactive screen display. A large scale, the Detroit, Michigan scene shows evidence of an along line data slip every sixteenth line in TM channel 2. Very large scale products generated in false color using channels 1,3, and 4 should be very acceptable for interpretation at scales up to 1:50,000 and useful for change mapping probably up to scale 1:24,000. Striping visible in water bodies for both natural and color products indicates that the detector calibration is probably performing below preflight specification. For a set of 512 x 512 windows within the NE Arkansas scene, the variance-covariance matrices were computed and principal component analyses performed. Initial analysis suggests that the shortwave infrared TM 5 and 6 channels are a highly significant data source. The thermal channel (TM 7) shows negative correlation with TM 1 and 4.

  16. Analysis of the quality of image data acquired by the LANDSAT-4 thematic mapper and multispectral scanners. [Plumas County, California

    NASA Technical Reports Server (NTRS)

    Colwell, R. N. (Principal Investigator)

    1984-01-01

    A seven step procedure developed for evaluating the geometric properties of MSS and TM film produces is being implemented. Some 476 control points were selected of which 238 are being tested and edited for digitization and scaling errors. Tables show statistics established for assessing the spectral characteristics and variability, as well as the spatial resolution and radiometric sensitivity of TM data for a forest environment in an effort to determine the extent to which major forest cover type can be detected and identified on TM digital and image products. Results thus far show that the high quality obtained are more than sufficient for meeting most of the inventory objectives of the renewable resource specialist. The TM data should be extremely valuable for: (1) estimating forest cover types; (2) updating land use survey maps; and (3) determining the size and shape and location of individual forest clearings and water resources.

  17. The reaction of formic acid with RaneyTM copper

    NASA Astrophysics Data System (ADS)

    Callear, Samantha K.; Silverwood, Ian P.; Chutia, Arunabhiram; Catlow, C. Richard A.; Parker, Stewart F.

    2016-04-01

    The interaction of formic acid with RaneyTM Cu proves to be complex. Rather than the expected generation of a monolayer of bidentate formate, we find the formation of a Cu(II) compound. This process occurs by direct reaction of copper and formic acid; in contrast, previous methods are by solution reaction. This is a rare example of formic acid acting as an oxidant rather than, as more commonly found, a reductant. The combination of diffraction, spectroscopic and computational methods has allowed this unexpected process to be characterized.

  18. In vitro and in vivo evaluation of novel implantation technology in hydrogel contact lenses for controlled drug delivery.

    PubMed

    Maulvi, Furqan A; Lakdawala, Dhara H; Shaikh, Anjum A; Desai, Ankita R; Choksi, Harsh H; Vaidya, Rutvi J; Ranch, Ketan M; Koli, Akshay R; Vyas, Bhavin A; Shah, Dinesh O

    2016-03-28

    Glaucoma is commonly treated using eye drops, which is highly inefficient due to rapid clearance (low residence time) from ocular surface. Contact lenses are ideally suited for controlled drug delivery to cornea, but incorporation of any drug loaded particulate system (formulation) affect the optical and physical property of contact lenses. The objective of the present work was to implant timolol maleate (TM) loaded ethyl cellulose nanoparticle-laden ring in hydrogel contact lenses that could provide controlled drug delivery at therapeutic rates without compromising critical lens properties. TM-implant lenses were developed, by dispersing TM encapsulated ethyl cellulose nanoparticles in acrylate hydrogel (fabricated as ring implant) and implanted the same in hydrogel contact lenses (sandwich system). The TM-ethyl cellulose nanoparticles were prepared by double emulsion method at different ratios of TM to ethyl cellulose. The X-ray diffraction studies revealed the transformation of TM to amorphous state. In vitro release kinetic data showed sustained drug release within the therapeutic window for 168h (NP 1:3 batch) with 150μg loading. Cytotoxicity and ocular irritation study demonstrated the safety of TM-implant contact lenses. In vivo pharmacokinetic studies in rabbit tear fluid showed significant increase in mean residence time (MRT) and area under curve (AUC), with TM-implant contact lenses in comparison to eye drop therapy. In vivo pharmacodynamic data in rabbit model showed sustained reduction in intra ocular pressure for 192h. The study demonstrated the promising potential of implantation technology to treat glaucoma using contact lenses, and could serve as a platform for other ocular diseases. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Comparison of reading speed with 3 different log-scaled reading charts

    PubMed Central

    Buari, Noor Halilah; Chen, Ai-Hong; Musa, Nuraini

    2014-01-01

    Background A reading chart that resembles real reading conditions is important to evaluate the quality of life in terms of reading performance. The purpose of this study was to compare the reading speed of UiTM Malay related words (UiTM-Mrw) reading chart with MNread Acuity Chart and Colenbrander Reading Chart. Materials and methods Fifty subjects with normal sight were randomly recruited through randomized sampling in this study (mean age = 22.98 ± 1.65 years). Subjects were asked to read three different near charts aloud and as quickly as possible at random sequence. The charts were the UiTM-Mrw Reading Chart, MNread Acuity Chart and Colenbrander Reading Chart, respectively. The time taken to read each chart was recorded and any errors while reading were noted. Reading performance was quantified in terms of reading speed as words per minute (wpm). Results The mean reading speed for UiTM-Mrw Reading Chart, MNread Acuity Chart and Colenbrander Reading Chart was 200 ± 30 wpm, 196 ± 28 wpm and 194 ± 31 wpm, respectively. Comparison of reading speed between UiTM-Mrw Reading Chart and MNread Acuity Chart showed no significant difference (t = −0.73, p = 0.72). The same happened with the reading speed between UiTM-Mrw Reading Chart and Colenbrander Reading Chart (t = −0.97, p = 0.55). Bland and Altman plot showed good agreement between reading speed of UiTM-Mrw Reading Chart with MNread Acuity Chart with the Colenbrander Reading Chart. Conclusion UiTM-Mrw Reading Chart in Malay language is highly comparable with standardized charts and can be used for evaluating reading speed. PMID:25323642

  20. Using the time and motion method to study clinical work processes and workflow: methodological inconsistencies and a call for standardized research.

    PubMed

    Zheng, Kai; Guo, Michael H; Hanauer, David A

    2011-01-01

    To identify ways for improving the consistency of design, conduct, and results reporting of time and motion (T&M) research in health informatics. We analyzed the commonalities and divergences of empirical studies published 1990-2010 that have applied the T&M approach to examine the impact of health IT implementation on clinical work processes and workflow. The analysis led to the development of a suggested 'checklist' intended to help future T&M research produce compatible and comparable results. We call this checklist STAMP (Suggested Time And Motion Procedures). STAMP outlines a minimum set of 29 data/ information elements organized into eight key areas, plus three supplemental elements contained in an 'Ancillary Data' area, that researchers may consider collecting and reporting in their future T&M endeavors. T&M is generally regarded as the most reliable approach for assessing the impact of health IT implementation on clinical work. However, there exist considerable inconsistencies in how previous T&M studies were conducted and/or how their results were reported, many of which do not seem necessary yet can have a significant impact on quality of research and generalisability of results. Therefore, we deem it is time to call for standards that can help improve the consistency of T&M research in health informatics. This study represents an initial attempt. We developed a suggested checklist to improve the methodological and results reporting consistency of T&M research, so that meaningful insights can be derived from across-study synthesis and health informatics, as a field, will be able to accumulate knowledge from these studies.

  1. Early thrombomodulin-α administration outcome for acute disseminated intravascular coagulopathy in gastrointestinal surgery.

    PubMed

    Konishi, Hirotaka; Okamoto, Kazuma; Shoda, Katsutoshi; Arita, Tomohiro; Kosuga, Toshiyuki; Morimura, Ryo; Komatsu, Shuhei; Murayama, Yasutoshi; Shiozaki, Atsushi; Kuriu, Yoshiaki; Ikoma, Hisashi; Nakanishi, Masayoshi; Ichikawa, Daisuke; Fujiwara, Hitoshi; Otsuji, Eigo

    2017-02-07

    To investigate the efficacy of thrombomodulin (TM)-α for treatment of disseminated intravascular coagulopathy (DIC) in the field of gastrointestinal surgery. Thirty-six peri-operative DIC patients in the field of gastrointestinal surgery who were treated with TM-α were retrospectively investigated. The relationships between patient demographics and the efficacy of TM-α were examined. Analysis of survival at 28 d was also performed on some parameters by means of the Kaplan-Meier method. Relationships between the initiation of TM-α and patient demographics were also evaluated. Abscess formation or bacteremia was the most frequent cause of DIC (33%), followed by digestive tract perforation (31%). Twenty-six patients developed DIC after surgery, frequently within 1 wk (81%). TM-α was most often administered within 1 d of the DIC diagnosis (72%) and was continued for more than 3 d (64%). Although bleeding tendency was observed in 7 patients (19%), a hemostatic procedure was not needed. DIC scores, systemic inflammatory response syndrome (SIRS) scores, quick-sequential organ failure assessment (qSOFA) scores, platelet counts, and prothrombin time ratios significantly improved after 1 wk ( P < 0.05, for all). The overall survival rate at 28 d was 71%. The duration of TM-α administration (≥ 4 , ≤ 6) and improvements in DIC-associated scores (DIC, SIRS and qSOFA) at 1 wk were significantly better prognostic factors for 28-d survival ( P < 0.05, for all). TM-α was administered significantly earlier to patients with severe clinical symptoms, such as high qSOFA scores, sepsis, shock or high lactate values ( P < 0.05, for all). Early administration of TM-α and improvements in each parameter were essential for treatment of DIC. The diagnosis of patients with mild symptoms requires further study.

  2. Aromatase inhibition by synthetic lactones and flavonoids in human placental microsomes and breast fibroblasts - A comparative study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meeuwen, J.A. van; Nijmeijer, S.; Mutarapat, T.

    2008-05-01

    Interference of exogenous chemicals with the aromatase enzyme can be useful as a tool to identify chemicals that could act either chemopreventive for hormone-dependent cancer or adverse endocrine disruptive. Aromatase is the key enzyme in the biosynthesis of steroids, as it converts androgens to estrogens. Certain flavonoids, plant derived chemicals, are known catalytic aromatase inhibitors. Various systems are in use to test aromatase inhibitory properties of compounds. Commonly used are microsomes derived from ovary or placental tissue characterized by high aromatase activity. To a lesser extent whole cell systems are used and specifically cell systems that are potential target tissuemore » in breast cancer development. In this study aromatase inhibitory properties of fadrozole, 8-prenylnaringenin and a synthetic lactone (TM-7) were determined in human placental microsomes and in human primary breast fibroblasts. In addition, apigenin, chrysin, naringenin and two synthetic lactones (TM-8 and TM-9) were tested in human microsomes only. Comparison of the aromatase inhibitory potencies of these compounds between the two test systems showed that the measurement of aromatase inhibition in human placental microsomes is a good predictor of aromatase inhibition in human breast fibroblasts.« less

  3. Recent NASA/GSFC cryogenic measurements of the total hemispheric emissivity of black surface preparations

    NASA Astrophysics Data System (ADS)

    Tuttle, J.; Canavan, E.

    2015-12-01

    High-emissivity (black) surfaces are commonly used on deep-space radiators and thermal radiation absorbers in test chambers. Since 2011 NASA Goddard Space Flight Center has measured the total hemispheric emissivity of such surfaces from 20 to 300 K using a test apparatus inside a small laboratory cryostat. We report the latest data from these measurements, including Aeroglaze Z307 paint, Black Kapton, and a configuration of painted aluminum honeycomb that was not previously tested. We also present the results of batch-to- batch reproducibility studies in Ball Infrared BlackTM and painted aluminum honeycomb. Finally, we describe a recently-adopted temperature control method which significantly speeds the data acquisition, and we discuss efforts to reduce the noise in future data.

  4. Research and Process-Optimization on Mixed Crystal Caused Uneven-Performance of High-strength Structural Car Steel QStE500TM

    NASA Astrophysics Data System (ADS)

    Jian-wen, Li; Hong-yan, Liu

    Handan Iron and Steel production of high-strength structural car steel QStE500TM thin gauge products using Nb + Ti composite strengthening, with a small amount of Cr element to improve its hardenability, the process parameter control is inappropriate with Nb + Ti complex steel, it is easy to produce in the mixed crystal phenomenon, resulting in decreasing the toughness and uneven performance. In this paper, Gleeble 3500 thermal simulation testing machine for high-strength structural steel car QStE500TM product deformation austenite recrystallization behavior research, determined completely recrystallized, partial recrystallization and non-recrystallization region, provide theoretical basis and necessary data for reasonable controlled rolling process for production.

  5. Characterizing the scientific potential of satellite sensors. [San Francisco, California

    NASA Technical Reports Server (NTRS)

    1984-01-01

    Eleven thematic mapper (TM) radiometric calibration programs were tested and evaluated in support of the task to characterize the potential of LANDSAT TM digital imagery for scientific investigations in the Earth sciences and terrestrial physics. Three software errors related to integer overflow, divide by zero, and nonexist file group were found and solved. Raw, calibrated, and corrected image groups that were created and stored on the Barker2 disk are enumerated. Black and white pixel print files were created for various subscenes of a San Francisco scene (ID 40392-18152). The development of linear regression software is discussed. The output of the software and its function are described. Future work in TM radiometric calibration, image processing, and software development is outlined.

  6. Geological analysis of parts of the southern Arabian Shield based on Landsat imagery

    NASA Astrophysics Data System (ADS)

    Qari, Mohammed Yousef Hedaytullah T.

    This thesis examines the capability and applicability of Landsat multispectral remote sensing data for geological analysis in the arid southern Arabian Shield, which is the eastern segment of the Nubian-Arabian Shield surrounding the Red Sea. The major lithologies in the study area are Proterozoic metavolcanics, metasediments, gneisses and granites. Three test-sites within the study area, located within two tectonic assemblages, the Asir Terrane and the Nabitah Mobile Belt, were selected for detailed comparison of remote sensing methods and ground geological studies. Selected digital image processing techniques were applied to full-resolution Landsat TM imagery and the results are interpreted and discussed. Methods included: image contrast improvement, edge enhancement for detecting lineaments and spectral enhancement for geological mapping. The last method was based on two principles, statistical analysis of the data and the use of arithmetical operators. New and detailed lithological and structural maps were constructed and compared with previous maps of these sites. Examples of geological relations identified using TM imagery include: recognition and mapping of migmatites for the first time in the Arabian Shield; location of the contact between the Asir Terrane and the Nabitah Mobile Belt; and mapping of lithologies, some of which were not identified on previous geological maps. These and other geological features were confirmed by field checking. Methods of lineament enhancement implemented in this study revealed structural lineaments, mostly mapped for the first time, which can be related to regional tectonics. Structural analysis showed that the southern Arabian Shield has been affected by at least three successive phases of deformation. The third phase is the most dominant and widespread. A crustal evolutionary model in the vicinity of the study area is presented showing four stages, these are: arc stage, accretion stage, collision stage and post-collision stage. The results of this study demonstrate that Landsat TM data can be used reliably for geological investigations in the Arabian Shield and comparable areas, particularly to generate detailed geological maps over large areas by using quantitative remote sensing methods, providing there is prior knowledge of part of the area.

  7. Cost-utility analysis on telemonitoring of users with pacemakers: The PONIENTE study.

    PubMed

    Lopez-Villegas, Antonio; Catalan-Matamoros, Daniel; Robles-Musso, Emilio; Bautista-Mesa, Rafael; Peiro, Salvador

    2018-01-01

    Introduction Few studies have confirmed the cost-saving of telemonitoring of users with pacemakers (PMs). The purpose of this controlled, non-randomised, non-masked clinical trial was to perform an economic assessment of telemonitoring (TM) of users with PMs and check whether TM offers a cost-utility alternative to conventional follow-up in hospital. Methods Eighty-two patients implanted with an internet-based transmission PM were selected to receive either conventional follow-up in hospital ( n = 52) or TM ( n = 30) from their homes. The data were collected during 12 months while patients were being monitored. The economic assessment of the PONIENTE study was performed as per the perspectives of National Health Service (NHS) and patients. A cost-utility analysis was conducted to measure whether the TM of patients with PMs is cost-effective in terms of costs per gained quality-adjusted life years (QALYs). Results There was a significant cost-saving for participants in the TM group in comparison with the participants in the conventional follow-up group. From the NHS's perspective, the patients in the TM group gained 0.09 QALYs more than the patients in the conventional follow-up group over 12 months, with a cost saving of 57.64% (€46.51 versus €109.79, respectively; p < 0.001) per participant per year. In-office visits were reduced by 52.49% in the TM group. The costs related to the patient perspective were lower in the TM group than in the conventional follow-up group (€31.82 versus €73.48, respectively; p < 0.005). The costs per QALY were 61.68% higher in the in-office monitoring group. Discussion The cost-utility analysis performed in the PONIENTE study showed that the TM of users with PMs appears to be a significant cost-effective alternative to conventional follow-up in hospital.

  8. Non-invasive measurement of tibialis anterior muscle temperature during rest, cycling exercise and post-exercise recovery.

    PubMed

    Flouris, Andreas D; Dinas, Petros C; Tsitoglou, Kiriakos; Patramani, Ioanna; Koutedakis, Yiannis; Kenny, Glen P

    2015-07-01

    We introduce a non-invasive and accurate method to assess tibialis anterior muscle temperature (Tm) during rest, cycling exercise, and post-exercise recovery using the insulation disk (INDISK) technique. Twenty-six healthy males (23.6  ±  6.2 years; 24.1  ±  3.1 body mass index) were randomly allocated into the 'model' (n = 16) and the 'validation' (n = 10) groups. Participants underwent 20 min supine rest, 20 min cycling exercise at 60% of age-predicted maximum heart rate, and 20 min supine post-exercise recovery. In the model group, Tm (34.55  ±  1.02 °C) was greater than INDISK temperature (Tid; 32.44  ±  1.23 °C; p < 0.001) and skin surface temperature (Tsk; 29.84  ±  1.47 °C; p < 0.001) throughout the experimental protocol. The strongest prediction model (R(2) = 0.646) incorporated Tid and the difference between the current Tid temperature and that recorded four minutes before. No mean difference (p > 0.05) and a strong correlation (r = 0.804; p < 0.001) were observed between Tm and predicted Tm (predTm) in the model group. Cross-validation analyses in the validation group demonstrated no mean difference (p > 0.05), a strong correlation (r = 0.644; p < 0.001), narrow 95% limits of agreement (-0.06  ±  1.51), and low percent coefficient of variation (2.24%) between Tm (34.39  ±  1.00 °C) and predTm (34.45  ±  0.73 °C). We conclude that the novel technique accurately predicts Tm during rest, cycling exercise, and post-exercise recovery, providing a valid and cost-efficient alternative when direct Tm measurement is not feasible.

  9. GP50 as a promising early diagnostic antigen for Taenia multiceps infection in goats by indirect ELISA.

    PubMed

    Huang, Xing; Xu, Jing; Wang, Yu; Guo, Cheng; Chen, Lin; Gu, Xiaobin; Lai, Weimin; Peng, Xuerong; Yang, Guangyou

    2016-12-01

    Coenurosis is caused by coenurus, the metacestode of Taenia multiceps, which mainly parasitizes the brain and spinal cord of cattle, sheep and goats. To date, no widely-approved methods are available to identify early coenurus infection. In this study, we identified a full-length cDNA that encodes GP50 (TmGP50) from the transcriptome of T. multiceps, and then cloned and expressed in E. coli. The native proteins in adult stage and coenurus were located via immunofluorescence assays, while the potential of recombinant TmGP50 protein (rTmGP50) for indirect ELISA-based serodiagnostics was assessed using native goat sera. In addition, we orally infected 20 goats with mature T. multiceps eggs. Praziquantel (10%) was given to 10 of the goats 45 days post-infection (p.i.). Blood samples were collected for 17 weeks p.i. from the 20 goats and anti-rTmGP50 antibodies were evaluated using the indirect ELISA established here. The TmGP50 contains an 897 bp open reading frame, in which signal sequence resides in 1 ~ 48 sites and mature polypeptide consists of 282 amino acid residues. Immunofluorescence staining showed that native TmGP50 was localized to the microthrix and parenchymatous zone of the adult parasite and coenurus, and the coenurus cystic wall. The indirect ELISA based on rTmGP50 exhibited a sensitivity of 95.0% and a specificity of 92.6% when detecting GP50 antibodies in sera of naturally infected goats and sheep. In goats experimentally infected with T. multiceps, anti-TmGP50 antibody was detectable from 2 to 17 weeks p.i. in the control group, while the antibody fell below the cut-off value about 3 weeks after praziquantel treatment. Our results indicate that recombinant TmGP50 is a suitable early diagnostic antigen for coenurus infection in goats.

  10. Optical Analysis of Transparent Polymeric Material Exposed to Simulated Space Environment

    NASA Technical Reports Server (NTRS)

    Edwards, David L.; Finckenor, Miria M.

    2000-01-01

    Many innovations in spacecraft power and propulsion have been recently tested at NASA, particularly in non-chemical propulsion. One improvement in solar array technology is solar concentration using thin polymer film Fresnel lenses. Weight and cost savings were proven with the Solar Concentrator Arrays with Refractive Linear Element Technology (SCARLET)-II array on NASA's Deep Space I spacecraft. The Fresnel lens concentrates solar energy onto high-efficiency solar cells, decreasing the area of solar cells needed for power. Continued efficiency of this power system relies on the thin film's durability in the space environment and maintaining transmission in the 300 - 1000 nm bandwidth. Various polymeric materials have been tested for use in solar concentrators, including Lexan(TM), polyethylene terephthalate (PET), several formulations of Tefzel(Tm) and Teflon(TM), and DC 93-500, the material selected for SCARLET-II. Also tested were several innovative materials including Langley Research Center's CPI and CP2 polymers and atomic oxygen- resistant polymers developed by Triton Systems, Inc. The Environmental Effects Group of the Marshall Space Flight Center's Materials, Processes, and Manufacturing Department exposed these materials to simulated space environment and evaluated them for any change in optical transmission. Samples were exposed to a minimum of 1000 equivalent Sun hours of near-UV radiation (250 - 400 nm wavelength). Materials that appeared robust after near-UV exposure were then exposed to charged particle radiation equivalent to a five-year dose in geosynchronous orbit. These exposures were performed in MSFC's Combined Environmental Effects Test Chamber, a unique facility with the capability to expose materials simultaneously or sequentially to protons, low-energy electrons, high-energy electrons, near UV radiation and vacuum UV radiation. Reflectance measurements can be made on the samples in vacuum. Prolonged exposure to the space environment will decrease the polymer film's transmission and thus reduce the conversion efficiency. A method was developed to normalize the transmission loss and thus rank the materials according to their tolerance to space environmental exposure. Spectral results and the material ranking according to transmission loss are presented.

  11. A Case Study Exploring the Use of GarageBand[TM] and an Electronic Bulletin Board in Preservice Music Education

    ERIC Educational Resources Information Center

    Vratulis, Vetta; Morton, Charlene

    2011-01-01

    This qualitative research study is an exploration of the merit and shortcomings of using a combination of the music software GarageBand[TM] and an electronic bulletin board to facilitate musical and peer learning in a 3-month elementary music methods curriculum and instruction course. A pedagogical objective of this assignment was to increase the…

  12. Healthy Buddies[TM] Reduces Body Mass Index Z-Score and Waist Circumference in Aboriginal Children Living in Remote Coastal Communities

    ERIC Educational Resources Information Center

    Ronsley, Rebecca; Lee, Andrew S.; Kuzeljevic, Boris; Panagiotopoulos, Constadina

    2013-01-01

    Background: Aboriginal children are at increased risk for obesity and type 2 diabetes. Healthy Buddies [TM]-First Nations (HB) is a curriculum-based, peer-led program promoting healthy eating, physical activity, and self-esteem. Methods: Although originally designed as a pilot pre-/post-analysis of 3 remote Aboriginal schools that requested and…

  13. Urodynamics findings in transverse myelitis patients with lower urinary tract symptoms: Results from a tertiary referral urodynamic center.

    PubMed

    Gliga, Louise A; Lavelle, Rebecca S; Christie, Alana L; Coskun, Burhan; Greenberg, Benjamin M; Carmel, Maude E; Lemack, Gary E

    2017-02-01

    To characterize urodynamic findings in patients referred with transverse myelitis (TM) and lower urinary tract symptoms (LUTS), as well as to identify any characteristics predictive of urodynamics findings. This is a retrospective review of an IRB-approved neurogenic bladder database of patients followed by a single surgeon between 2001 and 2013. Patient characteristics, questionnaire data, radiologic studies, and urodynamic parameters were analyzed. Of the 836 patients in the neurogenic bladder database, 28 patients (17 females, 11 males) were referred with a principle diagnosis of TM (3%). Twenty-one of twenty-eight patients (75%) underwent urodynamics testing. Bladder management at initial urologic evaluation was CIC or urethral catheter for 16/28 patients (57.1%). Median MCC was 303 ml (85-840 ml), detrusor overactivity (DO) was present in 16/21 (76%), detrusor sphincter dyssynergia (DSD) in 10/21 (48%), and decreased compliance in 7/21 (33%). For those voiding, mean Qmax was 12 ± 10 ml/sec and pdet at Qmax was 41 ± 17 cmH 2 O. Longitudinally extensive TM (LETM) was the only patient characteristic associated with DO (P = 0.0276). No other patient characteristics were associated with urodynamics parameters. Significant urodynamic testing abnormalities are noted in the majority of TM patients undergoing urodynamics, with 95% having DO, DSD, altered compliance, or detrusor underactivity. Other than the association between LETM and DO, there were no patient characteristics predictive of urodynamics findings. Based on the severity of urodynamics findings in our series, patients with TM and LUTS should have thorough baseline urological evaluations including urodynamics and be offered ongoing surveillance. Neurourol. Urodynam. 36:360-363, 2017. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  14. The first step in the development of text mining technology for cancer risk assessment: identifying and organizing scientific evidence in risk assessment literature

    PubMed Central

    Korhonen, Anna; Silins, Ilona; Sun, Lin; Stenius, Ulla

    2009-01-01

    Background One of the most neglected areas of biomedical Text Mining (TM) is the development of systems based on carefully assessed user needs. We have recently investigated the user needs of an important task yet to be tackled by TM -- Cancer Risk Assessment (CRA). Here we take the first step towards the development of TM technology for the task: identifying and organizing the scientific evidence required for CRA in a taxonomy which is capable of supporting extensive data gathering from biomedical literature. Results The taxonomy is based on expert annotation of 1297 abstracts downloaded from relevant PubMed journals. It classifies 1742 unique keywords found in the corpus to 48 classes which specify core evidence required for CRA. We report promising results with inter-annotator agreement tests and automatic classification of PubMed abstracts to taxonomy classes. A simple user test is also reported in a near real-world CRA scenario which demonstrates along with other evaluation that the resources we have built are well-defined, accurate, and applicable in practice. Conclusion We present our annotation guidelines and a tool which we have designed for expert annotation of PubMed abstracts. A corpus annotated for keywords and document relevance is also presented, along with the taxonomy which organizes the keywords into classes defining core evidence for CRA. As demonstrated by the evaluation, the materials we have constructed provide a good basis for classification of CRA literature along multiple dimensions. They can support current manual CRA as well as facilitate the development of an approach based on TM. We discuss extending the taxonomy further via manual and machine learning approaches and the subsequent steps required to develop TM technology for the needs of CRA. PMID:19772619

  15. Thermo-selective Tm(x)Ti(1-x)O(2-x/2) nanoparticles: from Tm-doped anatase TiO2 to a rutile/pyrochlore Tm2Ti2O7 mixture. An experimental and theoretical study with a photocatalytic application.

    PubMed

    Navas, Javier; Sánchez-Coronilla, Antonio; Aguilar, Teresa; De los Santos, Desireé M; Hernández, Norge C; Alcántara, Rodrigo; Fernández-Lorenzo, Concha; Martín-Calleja, Joaquín

    2014-11-07

    This is an experimental and theoretical study of thulium doped TiO2 nanoparticles. From an experimental perspective, a method was used to synthesize thulium-doped TiO2 nanoparticles in which Tm(3+) replaces Ti(4+) in the lattice, which to our knowledge has neither been reported nor studied theoretically so far. Different proportions of anatase and rutile phases were obtained at different annealing temperatures, and XRD and Raman spectroscopy also revealed the presence of a pyrochlore phase (Tm2Ti2O7) at 1173 K. Thus, the structure of the Tm-doped nanoparticles was thermally-controlled. Furthermore, XPS showed the presence of Tm(3+) in the samples synthesized, which produces oxygen vacancies to maintain the local neutrality in the lattice. The presence of Tm(3+) in the samples led to changes in the UV-Vis absorption spectra, so they showed photoluminescence properties and new states in the band gap, which produce a new lower energy electronic transition than the main TiO2 one. Periodic DFT calculations were performed to understand the experimentally produced structures. The production of oxygen vacancies was analysed and the changes generated in the structure were fully detailed. The DOS and PDOS analyses confirmed the experimental results obtained using UV-Vis spectroscopy, and showed that the new electronic states in the band gap are due to interactions of the f state of Tm and the p state of O. Likewise, the charge study and the ELF analysis indicate that when Tm is introduced into the TiO2 structure, the Ti-O bond around the oxygen vacancy is strengthened. Finally, an example of a photocatalytic application was developed to show the high efficiency of the samples due to the heterojunction in the interfaces of the phases in the samples, which improved the charge separation and the good charge carrier mobility due to the presence of the pyrochlore phase, as was also shown theoretically.

  16. Cross-sensor comparisons between Landsat 5 TM and IRS-P6 AWiFS and disturbance detection using integrated Landsat and AWiFS time-series images

    USGS Publications Warehouse

    Chen, Xuexia; Vogelmann, James E.; Chander, Gyanesh; Ji, Lei; Tolk, Brian; Huang, Chengquan; Rollins, Matthew

    2013-01-01

    Routine acquisition of Landsat 5 Thematic Mapper (TM) data was discontinued recently and Landsat 7 Enhanced Thematic Mapper Plus (ETM+) has an ongoing problem with the scan line corrector (SLC), thereby creating spatial gaps when covering images obtained during the process. Since temporal and spatial discontinuities of Landsat data are now imminent, it is therefore important to investigate other potential satellite data that can be used to replace Landsat data. We thus cross-compared two near-simultaneous images obtained from Landsat 5 TM and the Indian Remote Sensing (IRS)-P6 Advanced Wide Field Sensor (AWiFS), both captured on 29 May 2007 over Los Angeles, CA. TM and AWiFS reflectances were compared for the green, red, near-infrared (NIR), and shortwave infrared (SWIR) bands, as well as the normalized difference vegetation index (NDVI) based on manually selected polygons in homogeneous areas. All R2 values of linear regressions were found to be higher than 0.99. The temporally invariant cluster (TIC) method was used to calculate the NDVI correlation between the TM and AWiFS images. The NDVI regression line derived from selected polygons passed through several invariant cluster centres of the TIC density maps and demonstrated that both the scene-dependent polygon regression method and TIC method can generate accurate radiometric normalization. A scene-independent normalization method was also used to normalize the AWiFS data. Image agreement assessment demonstrated that the scene-dependent normalization using homogeneous polygons provided slightly higher accuracy values than those obtained by the scene-independent method. Finally, the non-normalized and relatively normalized ‘Landsat-like’ AWiFS 2007 images were integrated into 1984 to 2010 Landsat time-series stacks (LTSS) for disturbance detection using the Vegetation Change Tracker (VCT) model. Both scene-dependent and scene-independent normalized AWiFS data sets could generate disturbance maps similar to what were generated using the LTSS data set, and their kappa coefficients were higher than 0.97. These results indicate that AWiFS can be used instead of Landsat data to detect multitemporal disturbance in the event of Landsat data discontinuity.

  17. Variability in spectral signatures of terrestrial volcanic rocks and implications for volcanology on Mars

    NASA Technical Reports Server (NTRS)

    Francis, P. W.

    1987-01-01

    The LANDSAT Thematic Mapper (TM) studies of 2.2 my old ignimbrites in a test area around the Cerro Galan Caldera, N. W. Argentina, show that the ignimbrites exhibit a remarkable range of spectral characteristics dependent both on intrinsic and extrinsic properties resulting from aeolian weathering processes. Spectral profiles of the ignimbrite in four contrasted environments were constructed using 6 TM bands. The textural and structural characteristics of ignimbrites on Mars were evaluated.

  18. Compact high-power microwave divider and combiner.

    PubMed

    Guo, L T; Chang, C; Huang, W H; Liu, Y S; Cao, Y B; Liu, C L; Sun, J

    2016-02-01

    A novel, compact, TM01-TE10 mode power divider and a novel, compact, four-way TE10-TM01 mode power combiner were theoretically designed and experimentally tested as a proof of principle. The theoretical and experimental S parameters are consistent with each other. High-power experiments show that their power capacities are no less than 1.5 GW and 3 GW, respectively. The devices have the merits of high power capacities and low insertion losses.

  19. DCE-MRI of hepatocellular carcinoma: perfusion quantification with Tofts model versus shutter-speed model--initial experience.

    PubMed

    Jajamovich, Guido H; Huang, Wei; Besa, Cecilia; Li, Xin; Afzal, Aneela; Dyvorne, Hadrien A; Taouli, Bachir

    2016-02-01

    To quantify hepatocellular carcinoma (HCC) perfusion and flow with the fast exchange regime-allowed Shutter-Speed model (SSM) compared to the Tofts model (TM). In this prospective study, 25 patients with HCC underwent DCE-MRI. ROIs were placed in liver parenchyma, portal vein, aorta and HCC lesions. Signal intensities were analyzed employing dual-input TM and SSM models. ART (arterial fraction), K (trans) (contrast agent transfer rate constant from plasma to extravascular extracellular space), ve (extravascular extracellular volume fraction), kep (contrast agent intravasation rate constant), and τi (mean intracellular water molecule lifetime) were compared between liver parenchyma and HCC, and ART, K (trans), v e and k ep were compared between models using Wilcoxon tests and limits of agreement. Test-retest reproducibility was assessed in 10 patients. ART and v e obtained with TM; ART, ve, ke and τi obtained with SSM were significantly different between liver parenchyma and HCC (p < 0.04). Parameters showed variable reproducibility (CV range 14.7-66.5% for both models). Liver K (trans) and ve; HCC ve and kep were significantly different when estimated with the two models (p < 0.03). Our results show differences when computed between the TM and the SSM. However, these differences are smaller than parameter reproducibilities and may be of limited clinical significance.

  20. Lipid-protein nanodiscs for cell-free production of integral membrane proteins in a soluble and folded state: comparison with detergent micelles, bicelles and liposomes.

    PubMed

    Lyukmanova, E N; Shenkarev, Z O; Khabibullina, N F; Kopeina, G S; Shulepko, M A; Paramonov, A S; Mineev, K S; Tikhonov, R V; Shingarova, L N; Petrovskaya, L E; Dolgikh, D A; Arseniev, A S; Kirpichnikov, M P

    2012-03-01

    Production of integral membrane proteins (IMPs) in a folded state is a key prerequisite for their functional and structural studies. In cell-free (CF) expression systems membrane mimicking components could be added to the reaction mixture that promotes IMP production in a soluble form. Here lipid-protein nanodiscs (LPNs) of different lipid compositions (DMPC, DMPG, POPC, POPC/DOPG) have been compared with classical membrane mimicking media such as detergent micelles, lipid/detergent bicelles and liposomes by their ability to support CF synthesis of IMPs in a folded and soluble state. Three model membrane proteins of different topology were used: homodimeric transmembrane (TM) domain of human receptor tyrosine kinase ErbB3 (TM-ErbB3, 1TM); voltage-sensing domain of K(+) channel KvAP (VSD, 4TM); and bacteriorhodopsin from Exiguobacterium sibiricum (ESR, 7TM). Structural and/or functional properties of the synthesized proteins were analyzed. LPNs significantly enhanced synthesis of the IMPs in a soluble form regardless of the lipid composition. A partial disintegration of LPNs composed of unsaturated lipids was observed upon co-translational IMP incorporation. Contrary to detergents the nanodiscs resulted in the synthesis of ~80% active ESR and promoted correct folding of the TM-ErbB3. None of the tested membrane mimetics supported CF synthesis of correctly folded VSD, and the protocol of the domain refolding was developed. The use of LPNs appears to be the most promising approach to CF production of IMPs in a folded state. NMR analysis of (15)N-Ile-TM-ErbB3 co-translationally incorporated into LPNs shows the great prospects of this membrane mimetics for structural studies of IMPs produced by CF systems. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Reliability and validity of the Chinese version of the Pediatric Quality Of Life InventoryTM (PedsQLTM) 3.0 neuromuscular module in children with Duchenne muscular dystrophy.

    PubMed

    Hu, Jun; Jiang, Li; Hong, Siqi; Cheng, Li; Kong, Min; Ye, Yuanzhen

    2013-03-15

    The Pediatric Quality of Life Inventory(TM) (PedsQL(TM)) is a widely used instrument to measure pediatric health-related quality of life (HRQOL) in children aged 2 to 18 years. The current study aimed to evaluate the reliability and validity of the Chinese version of the PedsQL(TM) 3.0 Neuromuscular Module in children with Duchenne muscular dystrophy (DMD). The PedsQL(TM) 3.0 Neuromuscular Module was translated into Chinese following PedsQL(TM) Measurement Model Translation Methodology. The Chinese version scale was administered to 56 children with DMD and their parents, and the psychometric properties were evaluated. The missing value percentages for each item of the Chinese version scale ranged from 0.00% to 0.54%. Internal consistency reliability approached or exceeded the minimum reliability standard of α = 0.7 (child α = 0.81, parent α = 0.86). Test-retest reliability was satisfactory, with intraclass correlation coefficients (ICCs) of 0.66 for children and 0.88 for parents (P < 0.01). Correlation coefficients between iteims and their hypothesized subscales were higher than those with other subscales (P < 0.05). The subscale of "About My/My Child's Neuromuscular Disease" significantly related to mobility and stair climbing status (Child t = 2.21, Parent t = 2.83, P < 0.05). The inter-correlations among the Chinese version of the PedsQL(TM) 3.0 Neuromuscular Module and the PedsQL(TM) 4.0 Generic Core Scales had medium to large effect sizes (P < 0.05). The child self-report scores were in moderate agreement with the parent proxy-report scores (ICC = 0.51, P < 0.05). The Chinese version of the PedsQLTM 3.0 Neuromuscular Module has acceptable psychometric properties. It is a reliable measure of disease-specific HRQOL in Chinese children with DMD.

  2. Performance Analysis of and Tool Support for Transactional Memory on BG/Q

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schindewolf, M

    2011-12-08

    Martin Schindewolf worked during his internship at the Lawrence Livermore National Laboratory (LLNL) under the guidance of Martin Schulz at the Computer Science Group of the Center for Applied Scientific Computing. We studied the performance of the TM subsystem of BG/Q as well as researched the possibilities for tool support for TM. To study the performance, we run CLOMP-TM. CLOMP-TM is a benchmark designed for the purpose to quantify the overhead of OpenMP and compare different synchronization primitives. To advance CLOMP-TM, we added Message Passing Interface (MPI) routines for a hybrid parallelization. This enables to run multiple MPI tasks, eachmore » running OpenMP, on one node. With these enhancements, a beneficial MPI task to OpenMP thread ratio is determined. Further, the synchronization primitives are ranked as a function of the application characteristics. To demonstrate the usefulness of these results, we investigate a real Monte Carlo simulation called Monte Carlo Benchmark (MCB). Applying the lessons learned yields the best task to thread ratio. Further, we were able to tune the synchronization by transactifying the MCB. Further, we develop tools that capture the performance of the TM run time system and present it to the application's developer. The performance of the TM run time system relies on the built-in statistics. These tools use the Blue Gene Performance Monitoring (BGPM) interface to correlate the statistics from the TM run time system with performance counter values. This combination provides detailed insights in the run time behavior of the application and enables to track down the cause of degraded performance. Further, one tool has been implemented that separates the performance counters in three categories: Successful Speculation, Unsuccessful Speculation and No Speculation. All of the tools are crafted around IBM's xlc compiler for C and C++ and have been run and tested on a Q32 early access system.« less

  3. Suggested Procedures for Installing Strain Gauges on Langley Research Center Wind Tunnel Balances, Custom Force Measuring Transducers, Metallic and Composite Structural Test Articles

    NASA Technical Reports Server (NTRS)

    Moore, Thomas C., Sr.

    2004-01-01

    The character of force and strain measurement testing at LaRC is such that the types of strain gauge installations, the materials upon which the strain gauges are applied, and the test environments encountered, require many varied approaches. In 1997, a NASA Technical Memorandum (NASA TM 110327) was generated to provide the strain gauge application specialist with a listing of recommended procedures for strain gauging various transducers and test articles at LaRC. The technical memorandum offered here is an effort to keep the strain gauge user informed of new technological enhancements in strain-gauging methodology while preserving the strain-gauging guidelines set forth in the 1997 TM. This document provides detailed recommendations for strain gauging LaRC-designed balances and custom transducers, composite materials, cryogenic and high-temperature test articles, and selected non-typical or unique materials or test conditions. Additionally, one section offers details for installing Bragg-Grating type fiber-optic strain sensors for non-typical test scenarios.

  4. Simulation-based education for transfusion medicine.

    PubMed

    Morgan, Shanna; Rioux-Masse, Benjamin; Oancea, Cristina; Cohn, Claudia; Harmon, James; Konia, Mojca

    2015-04-01

    The administration of blood products is frequently determined by physicians without subspecialty training in transfusion medicine (TM). Education in TM is necessary for appropriate utilization of resources and maintaining patient safety. Our institution developed an efficient simulation-based TM course with the goal of identifying key topics that could be individualized to learners of all levels in various environments while also allowing for practice in an environment where the patient is not placed at risk. A 2.5-hour simulation-based educational activity was designed and taught to undergraduate medical students rotating through anesthesiology and TM elective rotations and to all Clinical Anesthesia Year 1 (CA-1) residents. Content and process evaluation of the activity consisted of multiple-choice tests and course evaluations. Seventy medical students and seven CA-1 residents were enrolled in the course. There was no significant difference on pretest results between medical students and CA-1 residents. The posttest results for both medical students and CA-1 residents were significantly higher than pretest results. The results of the posttest between medical students and CA-1 residents were not significantly different. The TM knowledge gap is not a trivial problem as transfusion of blood products is associated with significant risks. Innovative educational techniques are needed to address the ongoing challenges with knowledge acquisition and retention in already full curricula. Our institution developed a feasible and effective way to integrate TM into the curriculum. Educational activities, such as this, might be a way to improve the safety of transfusions. © 2014 AABB.

  5. Maturation of Rb+ and PAH accumulation by rabbit anterior uvea and choroid plexus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krupin, T.; Fritz, C.; Becker, B.

    In vitro accumulation of radioactive para-aminohippuric acid (/sup 3/H-PAH) and rubidium (/sup 86/Rb+) by the anterior uvea, ciliary processes, and the choroid plexus was evaluated in tissues from newborn and various aged rabbits. Accumulation of PAH was present in the anterior uvea at 1 day of age (tissue to media ratio, T/M, of 2.1 +/- 0.2) and remained at this level for the first 14 days of life. Accumulation did not rise to adult levels until 21 days of age (T/M 5.5 +/- 0.6). Rubidium accumulation in the anterior uvea, a measure of Na+, K+-pump activity, was higher than adultmore » values 6 hr after birth (T/M25.2 +/- 0.9). Activity remained elevated through day 28 and did not fall to adult levels until day 60 (T/M 13.4 +/- 0.6). Accumulation studies on isolated ciliary processes were similar to those obtained from anterior uveal tissue. Daily subcutaneous injections of penicillin (300,000 units/kg/day) for 1 week had no effect on anterior uvea PAH accumulation (penicillin T/M was 1.7 +/- 0.1 and saline control T/M was 2.0 +/- 0.2). Accumulation of either /sup 3/H-PAH or /sup 86/Rb+ by the choroid plexus was present 1 day after birth in amounts that were similar to adult values and did not change during the 90 days of testing.« less

  6. Crashworthiness simulation of composite automotive structures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Botkin, M E; Johnson, N L; Simunovic, S

    1998-06-01

    In 1990 the Automotive Composites Consortium (ACC) began the investigation of crash worthiness simulation methods for composite materials. A contract was given to Livermore Software Technology Corporation (LSTC) to implement a new damage model in LS-DYNA3D TM specifically for composite structures. This model is in LS-DYNA3D TM and is in use by the ACC partners. In 1994 USCAR, a partnership of American auto companies, entered into a partnership called SCAAP (Super Computing Automotive Applications Partnership) for the express purpose of working with the National Labs on computational oriented research. A CRADA (Cooperative Research and Development Agreement) was signed with Lawrencemore » Livermore National Laboratory, Oak Ridge National Laboratory, Sandia National Laboratory, Argonne National Laboratory, and Los Alamos National Laboratory to work in three distinctly different technical areas, one of which was composites material modeling for crash worthiness. Each Laboratory was assigned a specific modeling task. The ACC was responsible for the technical direction of the composites project and provided all test data for code verification. All new models were to be implemented in DYNA3D and periodically distributed to all partners for testing. Several new models have been developed and implemented. Excellent agreement has been shown between tube crush simulation and experiments.« less

  7. A multiplexed method for kinetic measurements of apoptosis and proliferation using live-content imaging.

    PubMed

    Artymovich, Katherine; Appledorn, Daniel M

    2015-01-01

    In vitro cell proliferation and apoptosis assays are widely used to study cancer cell biology. Commonly used methodologies are however performed at a single, user-defined endpoint. We describe a kinetic multiplex assay incorporating the CellPlayer(TM) NucLight Red reagent to measure proliferation and the CellPlayer(TM) Caspase-3/7 reagent to measure apoptosis using the two-color, live-content imaging platform, IncuCyte(TM) ZOOM. High-definition phase-contrast images provide an additional qualitative validation of cell death based on morphological characteristics. The kinetic data generated using this strategy can be used to derive informed pharmacology measurements to screen potential cancer therapeutics.

  8. Luminescence of Er/Yb and Tm/Yb doped FAp nanoparticles and ceramics

    NASA Astrophysics Data System (ADS)

    Grigorjeva, L.; Smits, K.; Millers, D.; Jankoviča, Dz

    2015-03-01

    The nanoparticles of hydroxiapatite and fluorapatite doped with Er/Yb and Tm/Yb were synthesized and characterized by FTIR, XRD, SEM and TEM methods. The results of up-conversion luminescence studies were presented for the samples as prepared, annealed at 500°C and at 900-1000 °C. At annealing above 800°C the ceramic state was formed. It is shown that fluorapatite host is more appropriate than hydroxiapatite host for rare ions luminescence and up-conversion processes. The post preparing annealing of nanarticles significantly enhanced the luminescence intensity. The Tm/Yb doped fluorapatite shows intense up-conversion luminescence in 790-800 nm spectral region and is potentially useful for biomedical applications.

  9. Adhesion Strength Study of EVA Encapsulants on Glass Substrates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pern, F. J.; Glick, S. H.

    2003-05-01

    An extensive peel-test study was conducted to investigate the various factors that may affect the adhesion strength of photovoltaic module encapsulants, primarily ethylene-vinyl acetate (EVA), on glass substrates of various laminates based on a common configuration of glass/encapsulant/backfoil. The results show that"pure" or"absolute" adhesion strength of EVA-to-glass was very difficult to obtain because of tensile deformation of the soft, semi-elastic EVA layer upon pulling. A mechanically"strong enough" backing foil on the EVA was critical to achieving the"apparent" adhesion strength. Peel test method with a 90-degree-pull yielded similar results to a 180-degree-pull. The 90-degree-pull method better revealed the four stages ofmore » delamination failure of the EVA/backfoil layers. The adhesion strength is affected by a number of factors, which include EVA type, formulation, backfoil type and manufacturing source, glass type, and surface priming treatment on the glass surface or on the backfoil. Effects of the glass-cleaning method and surface texture are not obvious. Direct priming treatments used in the work did not improve, or even worsened, the adhesion. Aging of EVA by storage over~5 years reduced notably the adhesion strength. Lower adhesion strengths were observed for the blank (unformulated) EVA and non-EVA copolymers, such as poly(ethylene-co-methacrylate) (PEMA) or poly(ethylene-co-butylacrylate) (PEBA). Their adhesion strengths increased if the copolymers were cross-linked. Transparent fluoropolymer superstrates such as TefzelTM and DureflexTM films used for thin-film PV modules showed low adhesion strengths to the EVA at a level of~2 N/mm.« less

  10. Surface strain-field determination of tympanic membrane using 3D-digital holographic interferometry

    NASA Astrophysics Data System (ADS)

    Hernandez-Montes, María del S.; Mendoza Santoyo, Fernando; Muñoz, Silvino; Perez, Carlos; de la Torre, Manuel; Flores, Mauricio; Alvarez, Luis

    2015-08-01

    In order to increase the understanding of soft tissues mechanical properties, 3D Digital Holographic Interferometry (3D-DHI) was used to quantify the strain-field on a cat tympanic membrane (TM) surface. The experiments were carried out applying a constant sound-stimuli pressure of 90 dB SPL (0.632 Pa) on the TM at 1.2 kHz. The technique allows the accurate acquisition of the micro-displacement data along the x, y and z directions, which is a must for a full characterization of the tissue mechanical behavior under load, and for the calculation of the strain-field in situ. The displacements repeatability in z direction shows a standard deviation of 0.062 μm at 95% confidence level. In order to realize the full 3D characterization correctly the contour of the TM surface was measured employing the optically non-contact two-illumination positions contouring method. The x, y and z displacements combined with the TM contour data allow the evaluation its strain-field by spatially differentiating the u(m,n), v(m,n), and w(m,n) deformation components. The accurate and correct determination of the TM strain-field leads to describing its elasticity, which is an important parameter needed to improve ear biomechanics studies, audition processes and TM mobility in both experimental measurements and theoretical analysis of ear functionality and its modeling.

  11. 66.7-keV γ -line intensity of 171Tm determined via neutron activation

    NASA Astrophysics Data System (ADS)

    Weigand, M.; Heftrich, T.; Düllmann, Ch. E.; Eberhardt, K.; Fiebiger, S.; Glorius, J.; Göbel, K.; Haas, R.; Langer, C.; Lohse, S.; Reifarth, R.; Renisch, D.; Wolf, C.

    2018-03-01

    Background: About 50% of the heavy elements are produced in stars during the slow neutron capture process. The analysis of branching points allows to set constraints on the temperature and the neutron density in the interior of stars. The temperature dependence of the branch point 171Tm is weak. Hence, the 171Tm neutron capture cross section can be used to constrain the neutron density during the main component of the s process in thermally pulsing asymptotic giant branch stars. Purpose: In order to perform neutron capture experiments on 171Tm, sample material has to be produced and characterized. The characterization is done by γ spectroscopy, relying on the intensities of the involved γ lines. Only the 66.7-keV γ line can be observed whose intensity was uncertain so far. Method: An enriched 170Er sample was activated with thermal neutrons at the TRIGA (Training, Research, Isotopes, General Atomics) research reactor at the Johannes Gutenberg-Universität Mainz. The activation resulted in an easily quantifiable number of 171Er nuclei that subsequently decayed to 171Tm. Result: The intensity of the 66.7-keV γ line of the 171Tm decay was measured to Iγ=(0.144 ±0.010 )% . Conclusions: Our result is in good agreement with the value found in the literature.

  12. Effects of a virtual reality and treadmill training on gait of subjects with multiple sclerosis: a pilot study.

    PubMed

    Peruzzi, Agnese; Cereatti, Andrea; Della Croce, Ugo; Mirelman, Anat

    2016-01-01

    Gait and cognitive deficits are common in multiple sclerosis (MS) and are negatively affected during dual-task walking. Treadmill (TM) training has been previously used to preserve locomotor activity in MS. Virtual reality (VR) engages the user in cognitive and motor activities simultaneously. A training combining TM and VR has been successfully adopted in several neurological diseases, but not in MS. This study aims at investigating the feasibility of a VR-based TM training program on gait of subjects with MS. Eight persons with relapsing-remitting MS were recruited to participate in a six-week VR-based TM training program. Gait analysis was performed both in single and dual task conditions. Clinical tests were used to assess walking endurance and obstacle negotiation. All the evaluations were performed before, immediately and one month after the training. Gait speed and stride length improved in dual task post-intervention and were retained at follow-up. An improved ability in negotiating obstacles was found across the evaluations. VR-based TM training program is feasible and safe for MS subjects with moderate disabilities and may positively affect gait under complex conditions, such as dual tasking and obstacle negotiation. Copyright © 2015. Published by Elsevier B.V.

  13. Performance evaluation and geologic utility of LANDSAT-4 thematic mapper data

    NASA Technical Reports Server (NTRS)

    Paylor, E. D.; Abrams, M. J.; Conel, J. E.; Kahle, A. B.; Lang, H. R.

    1985-01-01

    The overall objective of the project was to evaluate LANDSAT-4 Thematic Mapper (TM) data in the context of geologic applications. This involved a quantitative assessment of the data quality including the spatial and spectral characteristics realized by the instrument. Three test sites were selected for the study: (1) Silver Bell, Arizona; (2) Death Valley, California; and (3) Wind River/Bighorn Basin area, Wyoming. Conclusions include: (1) Artificial and natural targets can be used to atmospherically calibrate TM data and investigate scanner radiometry, atmospheric parameters, and construction of atmospheric Modulation Transfer Functions (MTF's), (2) No significant radiometric degradation occurs in TM data as a result of SCROUNGE processing; however, the data exhibit narrow digital number (DN) distributiosn suggesting that the configuration of the instrument is not optimal for each science applications, (30 Increased spatial resolution, 1:24,000 enlargement capability, and good geometric fidelity of TM data allow accurate photogeologic/geomorphic mapping, including relative age dating of alluvial fans, measurement of structural and bedding attitudes, and construction of such things as structural cross sections and stratigraphic columns. (4) TM bands 5 and 7 are particularly useful for geologic applications because they span a region of the spectrum not previously sampled by multispectral scanner data and are important for characterizing clay and carbonate materials.

  14. Effect of meditation on psychological distress and brain functioning: A randomized controlled study.

    PubMed

    Travis, Fred; Valosek, Laurent; Konrad, Arthur; Link, Janice; Salerno, John; Scheller, Ray; Nidich, Sanford

    2018-06-21

    Psychological stability and brain integration are important factors related to physical and mental health and organization effectiveness. This study tested whether a mind-body technique, the Transcendental Meditation (TM) program could increase EEG brain integration and positive affect, and decrease psychological distress in government employees. Ninety-six central office administrators and staff at the San Francisco Unified School District were randomly assigned to either immediate start of the TM program or to a wait-list control group. At baseline and four-month posttest, participants completed an online version of the Profile of Mood States questionnaire (POMS). In addition, a subset of this population (N = 79) had their EEG recorded at baseline and at four-month posttest to calculate Brain Integration Scale (BIS) scores. At posttest, TM participants significantly decreased on the POMS Total Mood Disturbance and anxiety, anger, depression, fatigue, and confusion subscales, and significantly increased in the POMS vigor subscale. TM participants in the EEG-subgroup also significantly increased in BIS scores. Compliance with meditation practice was high (93%). Findings indicate the feasibility and effectiveness of implementing the TM program to improve brain integration and positive affect and reduce psychological distress in government administrators and staff. Copyright © 2018. Published by Elsevier Inc.

  15. Thematic Mapper Data Quality and Performance Assessment in Renewable Resources/agriculture Remote Sensing

    NASA Technical Reports Server (NTRS)

    Bizzell, R. M.; Prior, H. L.

    1984-01-01

    It is believed that the increased spatial resolution will provide solutions to proportion estimation error due to mixed pixels, and the increased spectral resolution will provide for the identification of important agricultural features such as crop stage, and condition. The results of analyses conducted relative to these hypothesis from sample segments extracted from the 4-band Detroit scene and the 7-band Mississippi County, Arkansas engineering test scene are described. Several studies were conducted to evaluate the geometric and radiometric performance of the TM to determine data viability for the more pertinent investigations of TM utility. In most cases this requirement was more than sufficiently satisfied. This allowed the opportunity to take advantage of detailed ground observations for several of the sample segments to assess class separability and detection of other important features with TM. The results presented regarding these TM characteristics show that not only is the increased definition of the within scene variance captured by the increased spatial and spectral resolution, but that the mid-IR bands (5 and 7) are necessary for optimum crop type classification. Both qualitative and quantitative results are presented that describe the improvements gained with the TM both relative to the MSS and on its own merit.

  16. Endoplasmic reticulum stress sensitizes human esophageal cancer cell to radiation.

    PubMed

    Pang, Xue-Li; He, Gang; Liu, Yang-Bo; Wang, Yan; Zhang, Bo

    2013-03-21

    To investigate the role of endoplasmic reticulum (ER) stress in cancer radiotherapy and its molecular mechanism. Tunicamycin (TM) was applied to induce ER stress in human esophageal cancer cell line EC109, and the radiosensitization effects were detected by acute cell death and clonogenic survival assay. Cell cycle arrest induced by TM was determined by flow cytometric analysis after the cellular DNA content was labeled with propidium iodide. Apoptosis of EC109 cells induced by TM was detected by annexin V staining and Western blotting of caspase-3 and its substrate poly ADP-ribose polymerase. Autophagic response was determined by acridine orange (AO) staining and Western blotting of microtubule-associated protein-1 light chain-3 (LC3) and autophagy related gene 5 (ATG5). In order to test the biological function of autophagy, specific inhibitor or Beclin-1 knockdown was used to inhibit autophagy, and its effect on cell apoptosis was thus detected. Additionally, involvement of the phosphatidylinositol-3 kinase (PI3K)/Akt/mammalian target of the rapamycin (mTOR) pathway was also detected by Western blotting. Finally, male nude mice inoculated subcutaneously with EC109 cells were used to confirm cell model observations. Our results showed that TM treatment enhanced cell death and reduced the colony survival fraction induced by ionizing radiation (IR), which suggested an obvious radiosensitization effect of TM. Moreover, TM and IR combination treatment led to a significant increase of G2/M phase and apoptotic cells, compared with IR alone. We also observed an increase of AO positive cells, and the protein level of LC3-II and ATG5 was induced by TM treatment, which suggested an autophagic response in EC109 cells. However, inhibition of autophagy by using a chemical inhibitor or Beclin-1 silencing led to increased cell apoptosis and decreased cell viability, which suggested a cytoprotective role of autophagy in stressed EC109 cells. Furthermore, TM treatment also activated mTORC1, and in turn reduced Akt phosphorylation, which suggested the PI3K/Akt/mTOR signal pathway was involved in the TM-induced autophagic response in EC109 cells. Tumor xenograft results also showed synergistic retarded tumor growth by TM treatment and IR, as well as the involvement of the PI3K/Akt/mTOR pathway. Our data showed that TM treatment sensitized human esophageal cancer cells to radiation via apoptosis and autophagy both in vitro and in vivo.

  17. Energy transfer characteristics of silicate glass doped with Er3+, Tm3+, and Ho3+ for ˜2 μm emission

    NASA Astrophysics Data System (ADS)

    Li, Ming; Liu, Xueqiang; Guo, Yanyan; Hu, Lili; Zhang, Junjie

    2013-12-01

    A Er3+/Tm3+/Ho3+ tri-doped silicate glass with good thermal stability is prepared by melt-quenching method. Efficient ˜2 μm emission is observed under 808 nm laser excitation. It is found that the 2.0 μm emission of Ho3+ can be enhanced under the excitation at 808 nm by incorporating Er3+ and Tm3+. Based on the measurement of absorption spectra, the Judd-Ofelt intensity parameters, radiation emission probability, and branching ratio are calculated to evaluate the spectroscopic properties simultaneously. The maximum value of emission cross section of Ho3+ is 3.54 × 10-21 cm2 at 2008 nm. Additionally, the phonon assistance and the micro-parameters in the energy transfer process are quantitatively analyzed by using Dexter model. The energy transfer coefficient from Tm3+ to Ho3+ can reach as high as 21.44 × 10-40 cm6/s, respectively. The emission property together with good thermal property indicates that Er3+/Tm3+/Ho3+ tri-doped silicate glass is a potential kind of laser glass for efficient 2 μm laser.

  18. Test-Takers' Strategic Behaviors in Independent and Integrated Speaking Tasks

    ERIC Educational Resources Information Center

    Barkaoui, Khaled; Brooks, Lindsay; Swain, Merrill; Lapkin, Sharon

    2013-01-01

    This study investigated the strategic behaviors that test-takers reported using when responding to integrated and independent speaking tasks in an English oral proficiency test [the Speaking Section of the Internet-based Test of English as a Foreign Language[TM] (TOEFL iBT)] and the relationship between test-takers' strategic behaviors and their…

  19. Results of Mechanical Testing for Pyroceram(tm) Glass-Ceramic

    NASA Technical Reports Server (NTRS)

    Choi, Sung R.; Gyekenyesi, John P.

    2003-01-01

    Mechanical testing for Pyroceram (trademark) 9606 glass-ceramic fabricated by Corning was conducted to determine mechanical properties of the material including slow crack growth.Valid testing was not achieved in tension, compression, and shear testing due to inappropriate test specimen configurations provided and primarily due to the existence of fortified layer( in tension).

  20. [RDBH-method and big DyeTM terminator technology in accurate diagnosis of β-thalassemia and the allelic polymorphism of β-globin cluster].

    PubMed

    Akperova, G A

    2014-11-01

    IThe purpose of this study was to evaluate of the efficiency of RDBH-method and Big DyeTM Terminator technology in an accurate diagnosis of β-thalassemia and the allelic polymorphism of β-globin cluster. It was done a complete hematology analysis (HB, MCH, MCV, MCHC, RBC, Hct, HbA2, HbF, Serum iron, Serum ferritin at four children (males, 6-10 years old) and their parents. Molecular analysis included Reverse Dot-Blot Hybridization StripAssay (RDBH) and DNA sequencing on ABI PRISM Big DyeTM Terminator. Hematologic and molecular parameters were contradictory. The homozygosity for β0-thalassemia (β0IVS2.1[G>A] and β0codon 8[-AA]) at three boys with the mild clinical manifestation and heterozygosity of their parents for mutations, and the absence of β-globin mutations at parents and a boy who holds monthly transfusion was established by RDBH-analysis. DNA sequencing by technology Big DyeTM Terminator showed polymorphism at positions -551 and -521 of Cap5'-region (-650-250) - (AT)7(T)7 and (AT)8(T)5. Application of the integrated clinical-molecular approach is an ideal method for an accurate diagnosis, identification of asymptomatic carriers and a reduce of the risk of complications from β-thalassemia, moreover screening of γG-gene and the level of fetal hemoglobin in early childhood will help manage of β-thalassemia clinic and prevent heavy consequences of the disease.

  1. Aptamer biosensor for Salmonella typhimurium detection based on luminescence energy transfer from Mn2 +-doped NaYF4:Yb, Tm upconverting nanoparticles to gold nanorods

    NASA Astrophysics Data System (ADS)

    Cheng, Keyi; Zhang, Jianguo; Zhang, Liping; Wang, Lun; Chen, Hongqi

    2017-01-01

    A highly sensitive luminescent bioassay for the detection of Salmonella typhimurium was fabricated using Mn2 +-doped NaYF4:Yb,Tm upconversion nanoparticles (UCNPs) as the donor and gold nanorods (Au NRs) as the acceptor and utilizing an energy transfer (LET) system. Mn2 +-doped NaYF4:Yb,Tm UCNPs with a strong emission peak at 807 nm were obtained by changing the doped ion ratio. Carboxyl-terminated Mn2 +-doped NaYF4:Yb,Tm UCNPs were coupled with S. typhimurium aptamers, which were employed to capture and concentrate S. typhimurium. The electrostatic interactions shorten the distance between the negatively charged donor and the positively charged acceptor, which results in luminescence quenching. The added S. typhimurium leads to the restoration of luminescence due to the formation of UCNPs-aptamers-S. typhimurium, which repels the UCNPs-aptamers from the Au NRs. The LET system does not occur because of the nonexistence of the luminescence emission band of Mn2 +-doped NaYF4:Yb,Tm UCNPs, which had large spectral overlap with the absorption band of Au NRs. Under optimal conditions, the linear range of detecting S. typhimurium was 12 to 5 × 105 cfu/mL (R = 0.99). The limit of detection for S. typhimurium was as low as 11 cfu/mL in an aqueous buffer. The measurement of S. typhimurium in milk samples was satisfied in accordance with the plate-counting method, suggesting that the proposed method was of practical value in the application of food security.

  2. Reticle inspection equipment productivity increase using SEMI specification for reticle and pod management

    NASA Astrophysics Data System (ADS)

    Taylor, Ron; Downey, Jack; Wood, Jeffrey; Lin, Yen-Hung; Bugata, Bharathi; Fan, Dongsheng; Hess, Carl; Wylie, Mark

    2016-10-01

    In this work, the SEMI specification for reticle and pod management (E109) with internal reticle library support has been integrated for the first time on KLA-Tencor's TeronTM and TeraScanTM reticle inspection tools. Manufacturing Execution System scheduling reticle jobs and Automated Material Handling System scheduling to transfer pods simultaneously have also been integrated and tested. GLOBALFOUNDRIES collaboratively worked with KLA-Tencor to successfully implement these capabilities. Both library and non-library scenarios have been demonstrated for comparison in a real production environment resulting in productivity increase of approximately 29% by making use of the library. Reticle re-qualification test cases were used for the comparison in this work.

  3. The MQXA quadrupoles for the LHC low-beta insertions

    NASA Astrophysics Data System (ADS)

    Ajima, Y.; Higashi, N.; Iida, M.; Kimura, N.; Nakamoto, T.; Ogitsu, T.; Ohhata, H.; Ohuchi, N.; Shintomi, T.; Sugawara, S.; Sugita, K.; Tanaka, K.; Taylor, T.; Terashima, A.; Tsuchiya, K.; Yamamoto, A.

    2005-09-01

    High-performance superconducting quadrupole magnets, MQXA, for the LHC low-beta insertions have been designed, manufactured in series and tested. The design field gradient of the quadrupole, which has a coil aperture of diameter 70 mm, was 240 T/m at 1.9 K; its effective length is 6.37 m, and it is required to operate reliably at up to 215 T/m when subjected to radiation heat deposit in the coils of up to 5 W/m. The series of 20 magnets has been produced in industry, and tested at KEK. The magnet design is explained, and the construction and performance of the series units, in terms of training, field quality and geometry, are presented.

  4. Mechanical Properties of LaRC(tm) SI Polymer for a Range of Molecular Weights

    NASA Technical Reports Server (NTRS)

    Whitley, Karen S.; Gates, Thomas S.; Hinkley, Jeffrey A.; Nicholson, Lee M.

    2000-01-01

    Mechanical testing of an advanced polyimide resin (LaRC(tm)-SI) with known variations in molecular weight was performed over a range of temperatures below the glass transition temperature. Elastic and inelastic properties were characterized as a function of molecular weight and test temperature. It was shown that notched tensile strength is a strong function of both temperature and molecular weight, whereas stiffness is only a strong function of temperature. The combined analysis of calculated yield stress and notched tensile strength indicated that low molecular weight materials tended to fail in a brittle manner, whereas high molecular weight materials exhibited ductile failure. The microphotographs of the failure surfaces also supported these findings.

  5. Analysis of the quality of image data acquired by the LANDSAT-4 thematic mapper and multispectral scanners

    NASA Technical Reports Server (NTRS)

    Colwell, R. N. (Principal Investigator)

    1983-01-01

    The three types of LANDSAT 4 film products generally accessible to the user community were analyzed and attempts were made to acquire a data set consisting of a variety of TM and MSS image products for the Sacramento and San Francisco Bay Area test sites. On request, the EDC developed an interim TM analytical film by using a leaser beam recorder to produce black and white masters from which natural and false color composites were created.

  6. Experimental and computational prediction of glass transition temperature of drugs.

    PubMed

    Alzghoul, Ahmad; Alhalaweh, Amjad; Mahlin, Denny; Bergström, Christel A S

    2014-12-22

    Glass transition temperature (Tg) is an important inherent property of an amorphous solid material which is usually determined experimentally. In this study, the relation between Tg and melting temperature (Tm) was evaluated using a data set of 71 structurally diverse druglike compounds. Further, in silico models for prediction of Tg were developed based on calculated molecular descriptors and linear (multilinear regression, partial least-squares, principal component regression) and nonlinear (neural network, support vector regression) modeling techniques. The models based on Tm predicted Tg with an RMSE of 19.5 K for the test set. Among the five computational models developed herein the support vector regression gave the best result with RMSE of 18.7 K for the test set using only four chemical descriptors. Hence, two different models that predict Tg of drug-like molecules with high accuracy were developed. If Tm is available, a simple linear regression can be used to predict Tg. However, the results also suggest that support vector regression and calculated molecular descriptors can predict Tg with equal accuracy, already before compound synthesis.

  7. Process effects resulting from an increased BARC thickness

    NASA Astrophysics Data System (ADS)

    Eakin, Ronald J.; Detweiler, Shangting F.; Stagaman, Gregory J.; Tesauro, Mark R.; Spak, Mark A.; Dammel, Ralph R.

    1997-07-01

    Process improvements attributed to the use of bottom anti- reflective coatings (B.A.R.C.s) are well documented. As our experience with these materials improves, so does our understanding of additional optimization. Recent supplier experiments suggest an increase in the thickness of AZR BARLiTM (bottom anti-reflective layer i-line) solution to reduce photoresist swing curve ratios. Also, changes in thin film stack on common substrates can adversely affect the degree of photoresist reflective notching. It is therefore of extreme importance to determine optimum thickness(es) of a B.A.R.C. material to ensure maximum process potential. We document several process effects in the conversion of a SRAM test device (0.38 - 0.45 micrometers) from a 650 angstrom to a 2000 angstrom BARLiTM film thickness using conventional i-line photolithography. Critical dimension (CD) uniformity and depth of focus (DOF) are evaluated. Defect density between the two processes are compared before and after etch employing optical metrology and electrical test structures. Sensitivity of overlay as a function of BARLiTM film thickness is investigated as well.

  8. Effect of Environment on Fatigue Behavior of a Nicalon(TM)/Si-N-C Ceramic Matrix Composite

    NASA Technical Reports Server (NTRS)

    Kalluri, Sreeramesh; Ojard, Greg C.; Verrilli, Michael J.; Kiraly, Louis J. (Technical Monitor)

    2002-01-01

    The effect of environmental exposure on the fatigue life of Nicalon(TM) /Si-N-C composite was investigated in this study. Test specimens with arrays of 1.8 mm diameter holes and two different open areas, 25 and 35%, were machined. Three environmental conditions were studied: 1) continuous fatigue cycling in air, 2) fatigue cycling in air alternating with humidity exposure, and 3) fatigue cycling in air alternating with exposure to a salt-fog environment. All fatigue testing on specimens with holes was performed with a load ratio, R = 0.05, and at a temperature of 910 C. In general, fatigue lives were shortest for specimens subjected to salt-fog exposure and longest for specimens subjected to continuous fatigue cycling in air. The fatigue data generated on the specimens with holes were compared with fatigue data generated in air on specimens with no holes. Fatigue strength reduction factors for different environmental conditions and open areas investigated in the study were calculated for the Nicalon(TM) /Si-N-C composite.

  9. Infrared wire-grid polarizer with sol-gel antireflection films on both sides

    NASA Astrophysics Data System (ADS)

    Yamada, Itsunari; Ishihara, Yoshiro

    2017-12-01

    We fabricated an infrared wire-grid polarizer with the high transverse magnetic (TM) polarization transmittance and high extinction ratio by soft imprint lithography, sol-gel method, and Al shadow coating processes. A zilconia film was coated on Si substrate by using sol-gel method and spin coating method. Then, sol-gel zirconia grating was formed on the back side using imprinting using a silicone mold. The polarizer was produced by depositing Al obliquely on the grating. The TM transmittance of the fabricated element was greater than 80% at a wavelength of 4.8 μm. The sol-gel zilconia films acted as antireflection films. The extinction ratio exceeded 26 dB at its wavelength.

  10. 77 FR 2979 - Regulation of Fuel and Fuel Additives: Modification to Octamix Waiver

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-20

    ... National Association of Corrosion Engineer's TM-01-72 (NACE RUST TEST). However, EPA concluded that compliance with the NACE Rust Test alone was not adequate in determining suitability of a corrosion inhibitor...

  11. Development of CO2 inversion system based on the adjoint of the global coupled transport model

    NASA Astrophysics Data System (ADS)

    Belikov, Dmitry; Maksyutov, Shamil; Chevallier, Frederic; Kaminski, Thomas; Ganshin, Alexander; Blessing, Simon

    2014-05-01

    We present the development of an inverse modeling system employing an adjoint of the global coupled transport model consisting of the National Institute for Environmental Studies (NIES) Eulerian transport model (TM) and the Lagrangian plume diffusion model (LPDM) FLEXPART. NIES TM is a three-dimensional atmospheric transport model, which solves the continuity equation for a number of atmospheric tracers on a grid spanning the entire globe. Spatial discretization is based on a reduced latitude-longitude grid and a hybrid sigma-isentropic coordinate in the vertical. NIES TM uses a horizontal resolution of 2.5°×2.5°. However, to resolve synoptic-scale tracer distributions and to have the ability to optimize fluxes at resolutions of 0.5° and higher we coupled NIES TM with the Lagrangian model FLEXPART. The Lagrangian component of the forward and adjoint models uses precalculated responses of the observed concentration to the surface fluxes and 3-D concentrations field simulated with the FLEXPART model. NIES TM and FLEXPART are driven by JRA-25/JCDAS reanalysis dataset. Construction of the adjoint of the Lagrangian part is less complicated, as LPDMs calculate the sensitivity of measurements to the surrounding emissions field by tracking a large number of "particles" backwards in time. Developing of the adjoint to Eulerian part was performed with automatic differentiation tool the Transformation of Algorithms in Fortran (TAF) software (http://www.FastOpt.com). This method leads to the discrete adjoint of NIES TM. The main advantage of the discrete adjoint is that the resulting gradients of the numerical cost function are exact, even for nonlinear algorithms. The overall advantages of our method are that: 1. No code modification of Lagrangian model is required, making it applicable to combination of global NIES TM and any Lagrangian model; 2. Once run, the Lagrangian output can be applied to any chemically neutral gas; 3. High-resolution results can be obtained over limited regions close to the monitoring sites (using the LPDM part), and at coarse resolution for the rest of the globe (using the Eulerian part), minimizing aggregation errors and computation cost. The adjoint of the coupled high-resolution Eulerian-Lagrangian model will be incorporated into the PYVAR CO2 variational inverse system (Chevallier et al., 2005). Chevallier, F., Fisher, M., Peylin, P., Serrar, S., Bousquet, P., Bréon, F.-M., Chédin, A., and Ciais, P.: Inferring CO2 sources and sinks from satellite observations: method and application to TOVS data, J. Geophys. Res., 110, D24309, doi:10.1029/2005JD006390, 2005.

  12. Prediction of the translocon-mediated membrane insertion free energies of protein sequences.

    PubMed

    Park, Yungki; Helms, Volkhard

    2008-05-15

    Helical membrane proteins (HMPs) play crucial roles in a variety of cellular processes. Unlike water-soluble proteins, HMPs need not only to fold but also get inserted into the membrane to be fully functional. This process of membrane insertion is mediated by the translocon complex. Thus, it is of great interest to develop computational methods for predicting the translocon-mediated membrane insertion free energies of protein sequences. We have developed Membrane Insertion (MINS), a novel sequence-based computational method for predicting the membrane insertion free energies of protein sequences. A benchmark test gives a correlation coefficient of 0.74 between predicted and observed free energies for 357 known cases, which corresponds to a mean unsigned error of 0.41 kcal/mol. These results are significantly better than those obtained by traditional hydropathy analysis. Moreover, the ability of MINS to reasonably predict membrane insertion free energies of protein sequences allows for effective identification of transmembrane (TM) segments. Subsequently, MINS was applied to predict the membrane insertion free energies of 316 TM segments found in known structures. An in-depth analysis of the predicted free energies reveals a number of interesting findings about the biogenesis and structural stability of HMPs. A web server for MINS is available at http://service.bioinformatik.uni-saarland.de/mins

  13. Relationship of saving habit determinants among undergraduate students: A case study of UiTM Negeri Sembilan, Kampus Seremban

    NASA Astrophysics Data System (ADS)

    Syahrom, N. S.; Nasrudin, N. S.; Mohamad Yasin, N.; Azlan, N.; Manap, N.

    2017-08-01

    It has been reported that students are already accumulating substantial debt from higher education fees and their spending habit are at a critical stage. These situations cause the youngsters facing bankruptcy if they cannot improve their saving habit. Many researches have acknowledged that the determinants of saving habit include financial management, parental socialization, peer influence, and self-control. However, there remains a need for investigating the relationship between these determinants in order to avoid bankruptcy among youngsters. The objectives of this study are to investigate the relationship between saving habit determinants and to generate a statistical model based on the determinants of saving habit. Data collection method used is questionnaire and its scope is undergraduate students of UiTM Negeri Sembilan, Kampus Seremban. Samples are chosen by using stratified probability sampling technique and cross-sectional method is used as the research design. The results are then analysed by using descriptive analysis, reliability test, Pearson Correlation, and Multiple Linear Regression analysis. It shows that saving habit and self-control has no relationship. It means that students with less self-control tend to save less. A statistical model has been generated that incorporated this relationship. This study is significant to help the students save more by having high self-control.

  14. Design and cold test of S-BAND cavity BPM for HLS

    NASA Astrophysics Data System (ADS)

    Luo, Qing; Sun, BaoGen; Jia, QiKa; He, DuoHui; Fang, Jia

    2011-12-01

    An S-band cavity BPM is designed for a new injector in National Synchrotron Radiation Laboratory. A re-entrant position cavity is tuned to the TM110 mode as position cavity. Cut-through waveguides are used as pickups to suppress the monopole signal. Theoretical resolution of this design is 31 nm. A prototype cavity BPM system is manufactured for off-line cold tests. The wire scanning method is used to calibrate the BPM and estimate the performance of the on-line BPM system. A cross-talk problem has been detected during the cold test. Racetrack cavity BPM design can be used to suppress the cross-talk. With the nonlinear effect being ignored, transform matrix can be used to correct cross-talk. Analysis of cold test results shows that the position resolution of prototype BPM is better than 3 μm.

  15. Traditional Medicine Collection Tracking System (TM-CTS): a database for ethnobotanically driven drug-discovery programs.

    PubMed

    Harris, Eric S J; Erickson, Sean D; Tolopko, Andrew N; Cao, Shugeng; Craycroft, Jane A; Scholten, Robert; Fu, Yanling; Wang, Wenquan; Liu, Yong; Zhao, Zhongzhen; Clardy, Jon; Shamu, Caroline E; Eisenberg, David M

    2011-05-17

    Ethnobotanically driven drug-discovery programs include data related to many aspects of the preparation of botanical medicines, from initial plant collection to chemical extraction and fractionation. The Traditional Medicine Collection Tracking System (TM-CTS) was created to organize and store data of this type for an international collaborative project involving the systematic evaluation of commonly used Traditional Chinese Medicinal plants. The system was developed using domain-driven design techniques, and is implemented using Java, Hibernate, PostgreSQL, Business Intelligence and Reporting Tools (BIRT), and Apache Tomcat. The TM-CTS relational database schema contains over 70 data types, comprising over 500 data fields. The system incorporates a number of unique features that are useful in the context of ethnobotanical projects such as support for information about botanical collection, method of processing, quality tests for plants with existing pharmacopoeia standards, chemical extraction and fractionation, and historical uses of the plants. The database also accommodates data provided in multiple languages and integration with a database system built to support high throughput screening based drug discovery efforts. It is accessed via a web-based application that provides extensive, multi-format reporting capabilities. This new database system was designed to support a project evaluating the bioactivity of Chinese medicinal plants. The software used to create the database is open source, freely available, and could potentially be applied to other ethnobotanically driven natural product collection and drug-discovery programs. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  16. PSOFuzzySVM-TMH: identification of transmembrane helix segments using ensemble feature space by incorporated fuzzy support vector machine.

    PubMed

    Hayat, Maqsood; Tahir, Muhammad

    2015-08-01

    Membrane protein is a central component of the cell that manages intra and extracellular processes. Membrane proteins execute a diversity of functions that are vital for the survival of organisms. The topology of transmembrane proteins describes the number of transmembrane (TM) helix segments and its orientation. However, owing to the lack of its recognized structures, the identification of TM helix and its topology through experimental methods is laborious with low throughput. In order to identify TM helix segments reliably, accurately, and effectively from topogenic sequences, we propose the PSOFuzzySVM-TMH model. In this model, evolutionary based information position specific scoring matrix and discrete based information 6-letter exchange group are used to formulate transmembrane protein sequences. The noisy and extraneous attributes are eradicated using an optimization selection technique, particle swarm optimization, from both feature spaces. Finally, the selected feature spaces are combined in order to form ensemble feature space. Fuzzy-support vector Machine is utilized as a classification algorithm. Two benchmark datasets, including low and high resolution datasets, are used. At various levels, the performance of the PSOFuzzySVM-TMH model is assessed through 10-fold cross validation test. The empirical results reveal that the proposed framework PSOFuzzySVM-TMH outperforms in terms of classification performance in the examined datasets. It is ascertained that the proposed model might be a useful and high throughput tool for academia and research community for further structure and functional studies on transmembrane proteins.

  17. Characterization of a Diamond Ground Y-TZP and Reversion of the Tetragonal to Monoclinic Transformation.

    PubMed

    Candido, L M; Fais, Lmg; Ferreira, E B; Antonio, S G; Pinelli, Lap

    To characterize the surface of an yttria-stabilized zirconia (Y-TZP) ceramic after diamond grinding in terms of its crystalline phase, morphology, mean roughness (Ra), and wettability as well as to determine a thermal treatment to reverse the resulting tetragonal to monoclinic (t-m) transformation. Y-TZP specimens were distributed into different groups according to the actions (or no action) of grinding and irrigation. Grinding was accomplished using a diamond stone at a low speed. The samples were characterized by x-ray diffraction (XRD), scanning electron microscopy, goniometry, and profilometry. In situ high-temperature XRD was used to determine an annealing temperature to reverse the t-m transformation. Ra was submitted to the Kruskal-Wallis test, followed by the Dunn test (α=0.05). The volume fraction of the monoclinic phase and contact angle were submitted to one-way analysis of variance, followed by the Tukey test (α=0.05). Monoclinic zirconia was observed on the surface of samples after dry and wet grinding with a diamond stone. The volume fraction of the monoclinic phase was smaller on the dry ground samples (3.6%±0.3%) than on the wet ground samples (5.6%±0.3%). High-temperature XRD showed reversion of the t-m phase transformation, which started at 700°C and completed at 800°C in a conventional oven. Grinding with a diamond stone partially transformed the crystalline phase on the surface of a Y-TZP ceramic from tetragonal to monoclinic zirconia while simultaneously increasing the surface roughness and wettability. The t-m transformation could be reversed by heat treatment at 800°C or 900°C for 60 minutes or 1000°C for 30 minutes.

  18. Microtox(TM) characterization of foundry sand residuals

    USGS Publications Warehouse

    Bastian, K.C.; Alleman, J.E.

    1998-01-01

    Although foundry residuals, consisting mostly of waste Sands, represent a potentially attractive, high-volume resource for beneficial reuse applications (e.g. highway embankment construction), prospective end users are understandably concerned about unforeseen liabilities stemming from the use of these residuals. This paper, therefore, focuses on the innovative use of a microbial bioassay as a means of developing a characterization of environmental suitability extending beyond the analytical coverage already provided by mandated chemical-specific tests (i.e., TCLP, etc.). Microtox(TM) bioassays were conducted on leachates derived from residuals obtained at a wide range of facilities, including: 11 gray and ductile iron foundries plus one each steel and aluminum foundries. In addition, virgin sand samples were used to establish a relative 'natural' benchmark against which the waste foundry sands could then be compared in terms of their apparent quality. These bioassay tests were able to effectively 'fingerprint' those residuals whose bioassay behavior was comparable to that of virgin materials. In fact, the majority of gray and ductile iron foundry residuals tested during this reported study elicited Microtox(TM) response levels which fell within or below the virgin sand response range, consequently providing another quantifiable layer of Support for this industry's claim that their sands are 'cleaner than dirt.' However, negative Microtox(TM) responses beyond that of the virgin sands were observed with a number of foundry samples (i.e. four of the 11 gray or ductile iron sands plus both non-iron sands). Therefore, the latter results would suggest that these latter residuals be excluded from beneficial reuse for the immediate future, at least until the cause and nature of this negative response has been further identified.

  19. Microfabricated thermal modulator for comprehensive two-dimensional micro gas chromatography: design, thermal modeling, and preliminary testing.

    PubMed

    Kim, Sung-Jin; Reidy, Shaelah M; Block, Bruce P; Wise, Kensall D; Zellers, Edward T; Kurabayashi, Katsuo

    2010-07-07

    In comprehensive two-dimensional gas chromatography (GC x GC), a modulator is placed at the juncture between two separation columns to focus and re-inject eluting mixture components, thereby enhancing the resolution and the selectivity of analytes. As part of an effort to develop a microGC x microGC prototype, in this report we present the design, fabrication, thermal operation, and initial testing of a two-stage microscale thermal modulator (microTM). The microTM contains two sequential serpentine Pyrex-on-Si microchannels (stages) that cryogenically trap analytes eluting from the first-dimension column and thermally inject them into the second-dimension column in a rapid, programmable manner. For each modulation cycle (typically 5 s for cooling with refrigeration work of 200 J and 100 ms for heating at 10 W), the microTM is kept approximately at -50 degrees C by a solid-state thermoelectric cooling unit placed within a few tens of micrometres of the device, and heated to 250 degrees C at 2800 degrees C s(-1) by integrated resistive microheaters and then cooled back to -50 degrees C at 250 degrees C s(-1). Thermal crosstalk between the two stages is less than 9%. A lumped heat transfer model is used to analyze the device design with respect to the rates of heating and cooling, power dissipation, and inter-stage thermal crosstalk as a function of Pyrex-membrane thickness, air-gap depth, and stage separation distance. Experimental results are in agreement with trends predicted by the model. Preliminary tests using a conventional capillary column interfaced to the microTM demonstrate the capability for enhanced sensitivity and resolution as well as the modulation of a mixture of alkanes.

  20. Variations in the Characteristics of Craters of the Moon Lava Flows from Vent to Termination: Remotely Sensed Spectra and Field Observations

    NASA Astrophysics Data System (ADS)

    Hobson, V. R.; Shervais, J. W.

    2004-12-01

    Developing a method to characterize the physical, chemical and temporal aspects of terrestrial volcanics is a necessary step toward studying volcanics on other planetary bodies. Volcanoes and flows close to populated centers have been studied to varying degree, but remote volcanics remain largely unstudied. Remotely sensed data and derived information can be used to select field sites on Earth and on other planets. Scientists studying volcanics in dangerous areas would benefit from as much advance knowledge of the area as possible before beginning fieldwork. By using satellites and other remote sensing methods, information about the eruptive history can be derived and potentially, the hazard these remote volcanic areas may pose to current and future generations can be estimated. Using Landsat TM, ASTER and other remotely sensed data, the extent and characteristics of lava flows can be examined, but verification and refinement of these methods requires collection of data on the ground. Young lava flows at Craters of the Moon National Park were selected to test methods for remote mapping of recent volcanics. These late Pleistocene to Holocene basalt flows have been mapped to 1:100,000 scale (Kuntz et al, 1988) and have only minor vegetative cover. A range of remotely sensed spectral images were combined to optimize recovery of the mapped flows. Major flow units can be distinguished from each other using unsupervised classification of Landsat TM Bands 1-7, but differentiation of flows within these units presents greater difficulty. Principal component analyses revealed that during the daytime, thermal infrared variations outweigh variations in all other bands. Larger-scale features were observed like edge effects attributable to changes in surface roughness or texture that might occur at flow fronts or at boundaries between flows. Using a digitized version of the geologic map, TM and ASTER data for individual flows were isolated and examined for changes with distance from the source vent or fissure. Several flows were selected for further examination in the field, based on accessibility and scientific interest.

Top