Sample records for test methods sampling

  1. Drinking water test methods in crisis-afflicted areas: comparison of methods under field conditions.

    PubMed

    Merle, Roswitha; Bleul, Ingo; Schulenburg, Jörg; Kreienbrock, Lothar; Klein, Günter

    2011-11-01

    To simplify the testing of drinking water in crisis-afflicted areas (as in Kosovo in 2007), rapid test methods were compared with the standard test. For Escherichia coli and coliform pathogens, rapid tests were made available: Colilert(®)-18, P/A test with 4-methylumbelliferyl-β-D-glucoronid, and m-Endo Broth. Biochemical differentiation was carried out by Enterotube™ II. Enterococci were determined following the standard ISO test and by means of Enterolert™. Four hundred ninety-nine water samples were tested for E. coli and coliforms using four methods. Following the standard method, 20.8% (n=104) of the samples contained E. coli, whereas the rapid tests detected between 19.6% (m-Endo Broth, 92.0% concordance) and 20.0% (concordance: 93.6% Colilert-18 and 94.8% P/A-test) positive samples. Regarding coliforms, the percentage of concordant results ranged from 98.4% (P/A-test) to 99.0% (Colilert-18). Colilert-18 and m-Endo Broth detected even more positive samples than the standard method did. Enterococci were detected in 93 of 573 samples by the standard method, but in 92 samples by Enterolert (concordance: 99.5%). Considering the high-quality equipment and time requirements of the standard method, the use of rapid tests in crisis-afflicted areas is sufficiently reliable.

  2. [Comparison of the Conventional Centrifuged and Filtrated Preparations in Urine Cytology].

    PubMed

    Sekita, Nobuyuki; Shimosakai, Hirofumi; Nishikawa, Rika; Sato, Hiroaki; Kouno, Hiroyoshi; Fujimura, Masaaki; Mikami, Kazuo

    2016-03-01

    The urine cytology test is one of the most important tools for the diagnosis of malignant urinary tract tumors. This test is also of great value for predicting malignancy. However, the sensitivity of this test is not high enough to screen for malignant cells. In our laboratory, we were able to attain a high sensitivity of urine cytology tests after changing the preparation method of urine samples. The differences in the cytodiagnosis between the two methods are discussed here. From January 2012 to June 2013, 2,031 urine samples were prepared using the conventional centrifuge method (C method) ; and from September 2013 to March 2015, 2,453 urine samples were prepared using the filtration method (F method) for the cytology test. When the samples included in category 4 or 5, were defined as cytological positive, the sensitivities of this test with samples prepared using the F method were significantly high compared with samples prepared using the C method (72% vs 28%, p<0.001). The number of cells on the glass slides prepared by the F method was significantly higher than that of the samples prepared by the C method (p<0.001). After introduction of the F method, the number of f alse negative cases was decreased in the urine cytology test because a larger number of cells was seen and easily detected as atypical or malignant epithelial cells. Therefore, this method has a higher sensitivity than the conventional C method as the sensitivity of urine cytology tests relies partially on the number of cells visualized in the prepared samples.

  3. Comparison of Clark's presence-absence test and the membrane filter method for coliform detection in potable water samples.

    PubMed Central

    Pipes, W O; Minnigh, H A; Moyer, B; Troy, M A

    1986-01-01

    A total of 2,601 water samples from six different water systems were tested for coliform bacteria by Clark's presence-absence (P-A) test and by the membrane filter (MF) method. There was no significant difference in the fraction of samples positive for coliform bacteria for any of the systems tested. It was concluded that the two tests are equivalent for monitoring purposes. However, 152 samples were positive for coliform bacteria by the MF method but negative by the P-A test, and 132 samples were positive by the P-A test but negative by the MF method. Many of these differences for individual samples can be explained by random dispersion of bacteria in subsamples when the coliform density is low. However, 15 samples had MF counts greater than 3 and gave negative P-A results. The only apparent explanation for most of these results is that coliform bacteria were present in the P-A test bottles but did not produce acid and gas. Two other studies have reported more samples positive by Clark's P-A test than by the MF method. PMID:3532953

  4. Sensitivity and specificity of normality tests and consequences on reference interval accuracy at small sample size: a computer-simulation study.

    PubMed

    Le Boedec, Kevin

    2016-12-01

    According to international guidelines, parametric methods must be chosen for RI construction when the sample size is small and the distribution is Gaussian. However, normality tests may not be accurate at small sample size. The purpose of the study was to evaluate normality test performance to properly identify samples extracted from a Gaussian population at small sample sizes, and assess the consequences on RI accuracy of applying parametric methods to samples that falsely identified the parent population as Gaussian. Samples of n = 60 and n = 30 values were randomly selected 100 times from simulated Gaussian, lognormal, and asymmetric populations of 10,000 values. The sensitivity and specificity of 4 normality tests were compared. Reference intervals were calculated using 6 different statistical methods from samples that falsely identified the parent population as Gaussian, and their accuracy was compared. Shapiro-Wilk and D'Agostino-Pearson tests were the best performing normality tests. However, their specificity was poor at sample size n = 30 (specificity for P < .05: .51 and .50, respectively). The best significance levels identified when n = 30 were 0.19 for Shapiro-Wilk test and 0.18 for D'Agostino-Pearson test. Using parametric methods on samples extracted from a lognormal population but falsely identified as Gaussian led to clinically relevant inaccuracies. At small sample size, normality tests may lead to erroneous use of parametric methods to build RI. Using nonparametric methods (or alternatively Box-Cox transformation) on all samples regardless of their distribution or adjusting, the significance level of normality tests depending on sample size would limit the risk of constructing inaccurate RI. © 2016 American Society for Veterinary Clinical Pathology.

  5. Experimental Investigations on Subsequent Yield Surface of Pure Copper by Single-Sample and Multi-Sample Methods under Various Pre-Deformation.

    PubMed

    Liu, Gui-Long; Huang, Shi-Hong; Shi, Che-Si; Zeng, Bin; Zhang, Ke-Shi; Zhong, Xian-Ci

    2018-02-10

    Using copper thin-walled tubular specimens, the subsequent yield surfaces under pre-tension, pre-torsion and pre-combined tension-torsion are measured, where the single-sample and multi-sample methods are applied respectively to determine the yield stresses at specified offset strain. The rule and characteristics of the evolution of the subsequent yield surface are investigated. Under the conditions of different pre-strains, the influence of test point number, test sequence and specified offset strain on the measurement of subsequent yield surface and the concave phenomenon for measured yield surface are studied. Moreover, the feasibility and validity of the two methods are compared. The main conclusions are drawn as follows: (1) For the single or multi-sample method, the measured subsequent yield surfaces are remarkably different from cylindrical yield surfaces proposed by the classical plasticity theory; (2) there are apparent differences between the test results from the two kinds of methods: the multi-sample method is not influenced by the number of test points, test order and the cumulative effect of residual plastic strain resulting from the other test point, while those are very influential in the single-sample method; and (3) the measured subsequent yield surface may appear concave, which can be transformed to convex for single-sample method by changing the test sequence. However, for the multiple-sample method, the concave phenomenon will disappear when a larger offset strain is specified.

  6. Face recognition based on symmetrical virtual image and original training image

    NASA Astrophysics Data System (ADS)

    Ke, Jingcheng; Peng, Yali; Liu, Shigang; Li, Jun; Pei, Zhao

    2018-02-01

    In face representation-based classification methods, we are able to obtain high recognition rate if a face has enough available training samples. However, in practical applications, we only have limited training samples to use. In order to obtain enough training samples, many methods simultaneously use the original training samples and corresponding virtual samples to strengthen the ability of representing the test sample. One is directly using the original training samples and corresponding mirror samples to recognize the test sample. However, when the test sample is nearly symmetrical while the original training samples are not, the integration of the original training and mirror samples might not well represent the test samples. To tackle the above-mentioned problem, in this paper, we propose a novel method to obtain a kind of virtual samples which are generated by averaging the original training samples and corresponding mirror samples. Then, the original training samples and the virtual samples are integrated to recognize the test sample. Experimental results on five face databases show that the proposed method is able to partly overcome the challenges of the various poses, facial expressions and illuminations of original face image.

  7. Warm-Up Effect in Panelist-Articulated-2-Alternative Forced Choice Test.

    PubMed

    Bloom, David J; Baik, Hwa-Young; Lee, Soo-Yeun

    2018-01-01

    Panelist performance in discrimination tests has been shown to increase when warm-up samples are provided prior to the actual test. Samples are used prior to the actual test for the attribute articulation process of a panelist-articulated-2-alternative forced choice (PA-2-AFC) procedure; however, it is yet unknown if the pretest articulation phase adds to the power of this testing method as with the warm-up. The goal of the study was to determine if a "warm-up" effect was displayed in the PA-2-AFC test resulting in greater power compared to the researcher-designated-2-AFC (RD-2-AFC) test. A RD-2-AFC test, with and without warm-up samples, and a PA-2-AFC test were performed by 61 panelists. A reduced calorie, citrus-flavored, and carbonated beverage was used in the tests. During RD-2-AFC testing, panelists were asked to identify which sample was more sour. For PA-2-AFC testing, panelists individually articulated the nature and direction of the difference between the 2 samples through a pretesting articulation procedure. The articulated difference was, then, used in standard 2-AFC test procedure. A warm-up effect was observed when comparing the standard RD-2-AFC with and without warm-up samples. The addition of warm up samples significantly increased the power of the test, in addition, the PA-2-AFC method had lower power than the RD-2-AFC method. The increase in power with the addition of warm-up samples for the RD-2-AFC procedure supports literature findings on the benefit of providing warm-up samples. No warm-up effect can be attributed to the PA-2-AFC method evidenced by the overall low power observed, which may be attributed to sample complexity. Selecting a specified discrimination testing method is advantageous and can reduce costs of sensory testing, but has been considered unpractical when samples may differ in unknown ways. This research explores the use of panelist derived terms to circumvent the need for researchers to identify these differences and compares the results to using research designated terms in discrimination testing. Results from this study can be utilized in creating ways to incorporate more powerful methods into sensory discrimination testing plans and provides researchers with a means for selecting terms for use in specified discrimination testing methods. © 2017 Institute of Food Technologists®.

  8. On sample size of the kruskal-wallis test with application to a mouse peritoneal cavity study.

    PubMed

    Fan, Chunpeng; Zhang, Donghui; Zhang, Cun-Hui

    2011-03-01

    As the nonparametric generalization of the one-way analysis of variance model, the Kruskal-Wallis test applies when the goal is to test the difference between multiple samples and the underlying population distributions are nonnormal or unknown. Although the Kruskal-Wallis test has been widely used for data analysis, power and sample size methods for this test have been investigated to a much lesser extent. This article proposes new power and sample size calculation methods for the Kruskal-Wallis test based on the pilot study in either a completely nonparametric model or a semiparametric location model. No assumption is made on the shape of the underlying population distributions. Simulation results show that, in terms of sample size calculation for the Kruskal-Wallis test, the proposed methods are more reliable and preferable to some more traditional methods. A mouse peritoneal cavity study is used to demonstrate the application of the methods. © 2010, The International Biometric Society.

  9. 40 CFR 60.496 - Test methods and procedures.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Surface Coating Industry § 60.496 Test methods and procedures. (a) The reference methods in appendix A to...) Method 4 for stack gas moisture. (b) For Method 24, the coating sample must be a 1-litre sample collected... volume must be 0.003 dscm except that shorter sampling times or smaller volumes, when necessitated by...

  10. 40 CFR 60.496 - Test methods and procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Surface Coating Industry § 60.496 Test methods and procedures. (a) The reference methods in appendix A to...) Method 4 for stack gas moisture. (b) For Method 24, the coating sample must be a 1-litre sample collected... volume must be 0.003 dscm except that shorter sampling times or smaller volumes, when necessitated by...

  11. 40 CFR 60.496 - Test methods and procedures.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Surface Coating Industry § 60.496 Test methods and procedures. (a) The reference methods in appendix A to...) Method 4 for stack gas moisture. (b) For Method 24, the coating sample must be a 1-litre sample collected... volume must be 0.003 dscm except that shorter sampling times or smaller volumes, when necessitated by...

  12. 40 CFR 60.496 - Test methods and procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Surface Coating Industry § 60.496 Test methods and procedures. (a) The reference methods in appendix A to...) Method 4 for stack gas moisture. (b) For Method 24, the coating sample must be a 1-litre sample collected... volume must be 0.003 dscm except that shorter sampling times or smaller volumes, when necessitated by...

  13. 40 CFR 60.496 - Test methods and procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Surface Coating Industry § 60.496 Test methods and procedures. (a) The reference methods in appendix A to...) Method 4 for stack gas moisture. (b) For Method 24, the coating sample must be a 1-litre sample collected... volume must be 0.003 dscm except that shorter sampling times or smaller volumes, when necessitated by...

  14. Hog Charm II tetracycline test screening results compared with a liquid chromatography tandem mass spectrometry 10-μg/kg method.

    PubMed

    Salter, Robert; Holmes, Steven; Legg, David; Coble, Joel; George, Bruce

    2012-02-01

    Pork tissue samples that tested positive and negative by the Charm II tetracycline test screening method in the slaughter plant laboratory were tested with the modified AOAC International liquid chromatography tandem mass spectrometry (LC-MS-MS) method 995.09 to determine the predictive value of the screening method at detecting total tetracyclines at 10 μg/kg of tissue, in compliance with Russian import regulations. There were 218 presumptive-positive tetracycline samples of 4,195 randomly tested hogs. Of these screening test positive samples, 83% (182) were positive, >10 μg/kg by LC-MS-MS; 12.8% (28) were false violative, greater than limit of detection (LOD) but <10 μg/kg; and 4.2% (8) were not detected at the LC-MS-MS LOD. The 36 false-violative and not-detected samples represent 1% of the total samples screened. Twenty-seven of 30 randomly selected tetracycline screening negative samples tested below the LC-MS-MS LOD, and 3 samples tested <3 μg/kg chlortetracycline. Results indicate that the Charm II tetracycline test is effective at predicting hogs containing >10 μg/kg total tetracyclines in compliance with Russian import regulations.

  15. Tube and column agglutination technology for autocontrol testing.

    PubMed

    Courtney, J E; Vincent, J L; Indrikovs, A J

    2001-01-01

    The incidence of positive autocontrol test results with column agglutination technology is a concern. This study investigates the incidence and significance of positive autocontrols in the ID Micro Typing System (gel) and the Gamma ReACT (ReACT). The study encompassed a total of 1021 randomly selected samples from patients and 95 samples from donors collected during 1 month. The autocontrol testing was carried out according to the manufacturer's instructions for the column agglutination tests. The tube method was carried out using low-ionic-strength solution (LISS). The direct antiglobulin test (DAT) was performed using the tube method, and further investigated with elution studies if warranted. Seventy-nine patient's samples (7.74%) had a positive autocontrol: the gel test, 72 (91.13%); ReACT, 21 (26.58%); and the tube method, 27 (34.18%). Of the 79 positive autocontrols, 44 samples had a negative DAT. Of the samples with positive DAT results, only one possessed a clinically significant antibody, anti-D. Moreover, the same sample also tested positive in all three methods. Column agglutination techniques have increased sensitivity for a positive autocontrol beyond the conventional tube method. However, ReACT and gel tests differ significantly in their frequency of positives. Investigation of the significance of a positive autocontrol in column agglutination technology when the conventional tube method is also positive is suggested.

  16. Integrating conventional and inverse representation for face recognition.

    PubMed

    Xu, Yong; Li, Xuelong; Yang, Jian; Lai, Zhihui; Zhang, David

    2014-10-01

    Representation-based classification methods are all constructed on the basis of the conventional representation, which first expresses the test sample as a linear combination of the training samples and then exploits the deviation between the test sample and the expression result of every class to perform classification. However, this deviation does not always well reflect the difference between the test sample and each class. With this paper, we propose a novel representation-based classification method for face recognition. This method integrates conventional and the inverse representation-based classification for better recognizing the face. It first produces conventional representation of the test sample, i.e., uses a linear combination of the training samples to represent the test sample. Then it obtains the inverse representation, i.e., provides an approximation representation of each training sample of a subject by exploiting the test sample and training samples of the other subjects. Finally, the proposed method exploits the conventional and inverse representation to generate two kinds of scores of the test sample with respect to each class and combines them to recognize the face. The paper shows the theoretical foundation and rationale of the proposed method. Moreover, this paper for the first time shows that a basic nature of the human face, i.e., the symmetry of the face can be exploited to generate new training and test samples. As these new samples really reflect some possible appearance of the face, the use of them will enable us to obtain higher accuracy. The experiments show that the proposed conventional and inverse representation-based linear regression classification (CIRLRC), an improvement to linear regression classification (LRC), can obtain very high accuracy and greatly outperforms the naive LRC and other state-of-the-art conventional representation based face recognition methods. The accuracy of CIRLRC can be 10% greater than that of LRC.

  17. A new low-cost procedure for detecting nucleic acids in low-incidence samples: a case study of detecting spores of Paenibacillus larvae from bee debris.

    PubMed

    Ryba, Stepan; Kindlmann, Pavel; Titera, Dalibor; Haklova, Marcela; Stopka, Pavel

    2012-10-01

    American foulbrood, because of its virulence and worldwide spread, is currently one of the most dangerous diseases of honey bees. Quick diagnosis of this disease is therefore vitally important. For its successful eradication, however, all the hives in the region must be tested. This is time consuming and costly. Therefore, a fast and sensitive method of detecting American foulbrood is needed. Here we present a method that significantly reduces the number of tests needed by combining batches of samples from different hives. The results of this method were verified by testing each sample. A simulation study was used to compare the efficiency of the new method with testing all the samples and to develop a decision tool for determining when best to use the new method. The method is suitable for testing large numbers of samples (over 100) when the incidence of the disease is low (10% or less).

  18. Grouping methods for estimating the prevalences of rare traits from complex survey data that preserve confidentiality of respondents.

    PubMed

    Hyun, Noorie; Gastwirth, Joseph L; Graubard, Barry I

    2018-03-26

    Originally, 2-stage group testing was developed for efficiently screening individuals for a disease. In response to the HIV/AIDS epidemic, 1-stage group testing was adopted for estimating prevalences of a single or multiple traits from testing groups of size q, so individuals were not tested. This paper extends the methodology of 1-stage group testing to surveys with sample weighted complex multistage-cluster designs. Sample weighted-generalized estimating equations are used to estimate the prevalences of categorical traits while accounting for the error rates inherent in the tests. Two difficulties arise when using group testing in complex samples: (1) How does one weight the results of the test on each group as the sample weights will differ among observations in the same group. Furthermore, if the sample weights are related to positivity of the diagnostic test, then group-level weighting is needed to reduce bias in the prevalence estimation; (2) How does one form groups that will allow accurate estimation of the standard errors of prevalence estimates under multistage-cluster sampling allowing for intracluster correlation of the test results. We study 5 different grouping methods to address the weighting and cluster sampling aspects of complex designed samples. Finite sample properties of the estimators of prevalences, variances, and confidence interval coverage for these grouping methods are studied using simulations. National Health and Nutrition Examination Survey data are used to illustrate the methods. Copyright © 2018 John Wiley & Sons, Ltd.

  19. The special case of the 2 × 2 table: asymptotic unconditional McNemar test can be used to estimate sample size even for analysis based on GEE.

    PubMed

    Borkhoff, Cornelia M; Johnston, Patrick R; Stephens, Derek; Atenafu, Eshetu

    2015-07-01

    Aligning the method used to estimate sample size with the planned analytic method ensures the sample size needed to achieve the planned power. When using generalized estimating equations (GEE) to analyze a paired binary primary outcome with no covariates, many use an exact McNemar test to calculate sample size. We reviewed the approaches to sample size estimation for paired binary data and compared the sample size estimates on the same numerical examples. We used the hypothesized sample proportions for the 2 × 2 table to calculate the correlation between the marginal proportions to estimate sample size based on GEE. We solved the inside proportions based on the correlation and the marginal proportions to estimate sample size based on exact McNemar, asymptotic unconditional McNemar, and asymptotic conditional McNemar. The asymptotic unconditional McNemar test is a good approximation of GEE method by Pan. The exact McNemar is too conservative and yields unnecessarily large sample size estimates than all other methods. In the special case of a 2 × 2 table, even when a GEE approach to binary logistic regression is the planned analytic method, the asymptotic unconditional McNemar test can be used to estimate sample size. We do not recommend using an exact McNemar test. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Bayesian analysis of two diagnostic methods for paediatric ringworm infections in a teaching hospital.

    PubMed

    Rath, S; Panda, M; Sahu, M C; Padhy, R N

    2015-09-01

    Quantitatively, conventional methods of diagnosis of tinea capitis or paediatric ringworm, microscopic and culture tests were evaluated with Bayes rule. This analysis would help in quantifying the pervasive errors in each diagnostic method, particularly the microscopic method, as a long-term treatment would be involved to eradicate the infection by the use of a particular antifungal chemotherapy. Secondly, the analysis of clinical data would help in obtaining digitally the fallible standard of the microscopic test method, as the culture test method is taken as gold standard. Test results of 51 paediatric patients were of 4 categories: 21 samples were true positive (both tests positive), and 13 were true negative; the rest samples comprised both 14 false positive (microscopic test positivity with culture test negativity) and 3 false negative (microscopic test negativity with culture test positivity) samples. The prevalence of tinea infection was 47.01% in the population of 51 children. The microscopic test of a sample was efficient by 87.5%, in arriving at a positive result on diagnosis, when its culture test was positive; and, this test was efficient by 76.4%, in arriving at a negative result, when its culture test was negative. But, the post-test probability value of a sample with both microscopic and culture tests would be correct in distinguishing a sample from a sick or a healthy child with a chance of 71.5%. However, since the sensitivity of the analysis is 87.5%, the microscopic test positivity would be easier to detect in the presence of infection. In conclusion, it could be stated that Trychophyton rubrum was the most prevalent species; sensitivity and specificity of treating the infection, by antifungal therapy before ascertaining by the culture method remain as 0.8751 and 0.7642, respectively. A correct/coveted diagnostic method of fungal infection would be could be achieved by modern molecular methods (matrix-assisted laser desorption ionisation-time of flight mass spectrometry or fluorescence in situ hybridization or enzyme-linked immunosorbent assay [ELISA] or restriction fragment length polymorphism or DNA/RNA probes of known fungal taxa) in advanced laboratories. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  1. 29 CFR Appendix E to Subpart L of... - Test Methods for Protective Clothing

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... strength of the specimen shall be the average of the five highest peak loads of resistance registered for 3... convenience. (2) Test method for determining the strength of cloth by tearing: Trapezoid Method. A. Test... directions shall be tested from each sample unit. (ii) The tearing strength of the sample unit shall be the...

  2. 29 CFR Appendix E to Subpart L of... - Test Methods for Protective Clothing

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... strength of the specimen shall be the average of the five highest peak loads of resistance registered for 3... convenience. (2) Test method for determining the strength of cloth by tearing: Trapezoid Method. A. Test... directions shall be tested from each sample unit. (ii) The tearing strength of the sample unit shall be the...

  3. Valid statistical inference methods for a case-control study with missing data.

    PubMed

    Tian, Guo-Liang; Zhang, Chi; Jiang, Xuejun

    2018-04-01

    The main objective of this paper is to derive the valid sampling distribution of the observed counts in a case-control study with missing data under the assumption of missing at random by employing the conditional sampling method and the mechanism augmentation method. The proposed sampling distribution, called the case-control sampling distribution, can be used to calculate the standard errors of the maximum likelihood estimates of parameters via the Fisher information matrix and to generate independent samples for constructing small-sample bootstrap confidence intervals. Theoretical comparisons of the new case-control sampling distribution with two existing sampling distributions exhibit a large difference. Simulations are conducted to investigate the influence of the three different sampling distributions on statistical inferences. One finding is that the conclusion by the Wald test for testing independency under the two existing sampling distributions could be completely different (even contradictory) from the Wald test for testing the equality of the success probabilities in control/case groups under the proposed distribution. A real cervical cancer data set is used to illustrate the proposed statistical methods.

  4. 40 CFR 80.580 - What are the sampling and testing methods for sulfur?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... methods for sulfur? 80.580 Section 80.580 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... the sampling and testing methods for sulfur? The sulfur content of diesel fuel and diesel fuel... methodology is provided in § 80.330(b). (b) Test method for sulfur—(1) For ECA marine fuel subject to the 1...

  5. 40 CFR 80.580 - What are the sampling and testing methods for sulfur?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... methods for sulfur? 80.580 Section 80.580 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... the sampling and testing methods for sulfur? The sulfur content of diesel fuel and diesel fuel... methodology is provided in § 80.330(b). (b) Test method for sulfur—(1) For ECA marine fuel subject to the 1...

  6. 40 CFR 80.580 - What are the sampling and testing methods for sulfur?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... methods for sulfur? 80.580 Section 80.580 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... the sampling and testing methods for sulfur? The sulfur content of diesel fuel and diesel fuel... methodology is provided in § 80.330(b). (b) Test method for sulfur—(1) For ECA marine fuel subject to the 1...

  7. Survey of South African fruit juices using a fast screening HILIC-MS method.

    PubMed

    Stander, Marietjie A; Kühn, Wernich; Hiten, Nicholas F

    2013-01-01

    Adulteration of fruit juices--by the addition of sugar or other less expensive fruit juices as well as preservatives, artificial sweeteners and colours--was tested for by using a developed screening method. The method employs hydrophilic interaction liquid chromatography-mass spectrometry (HILIC-MS) using electrospray ionisation in the negative mode and ultraviolet light detection. Different fruit juices can be differentiated by the content of marker compounds like sorbitol, certain phenolic molecules and their saccharide profile. This method was used to test 46 fruit juice samples from the retail market as well as 12 control samples. The study focused on the main types of fruit juices consumed on the South African market including apple, orange, grape and blends of these juices with other fruits like mango, pear and guava. Overall, the 46 samples tested mostly agreed with label claims. One grape juice sample was adulterated, probably with apple juice. Natamycin above the legal limits was found in two samples. In addition, two samples contained natamycin and one sample benzoate without it being indicated on the label. The method is well suited as a quick screening method for fruit juice adulteration and if used routinely would reduce fruit juice adulteration without the cost of the current array of tests needed for authenticity testing.

  8. Calculating p-values and their significances with the Energy Test for large datasets

    NASA Astrophysics Data System (ADS)

    Barter, W.; Burr, C.; Parkes, C.

    2018-04-01

    The energy test method is a multi-dimensional test of whether two samples are consistent with arising from the same underlying population, through the calculation of a single test statistic (called the T-value). The method has recently been used in particle physics to search for samples that differ due to CP violation. The generalised extreme value function has previously been used to describe the distribution of T-values under the null hypothesis that the two samples are drawn from the same underlying population. We show that, in a simple test case, the distribution is not sufficiently well described by the generalised extreme value function. We present a new method, where the distribution of T-values under the null hypothesis when comparing two large samples can be found by scaling the distribution found when comparing small samples drawn from the same population. This method can then be used to quickly calculate the p-values associated with the results of the test.

  9. Preliminary evaluation of a gel tube agglutination major cross-match method in dogs.

    PubMed

    Villarnovo, Dania; Burton, Shelley A; Horney, Barbara S; MacKenzie, Allan L; Vanderstichel, Raphaël

    2016-09-01

    A major cross-match gel tube test is available for use in dogs yet has not been clinically evaluated. This study compared cross-match results obtained using the gel tube and the standard tube methods for canine samples. Study 1 included 107 canine sample donor-recipient pairings cross-match tested with the RapidVet-H method gel tube test and compared results with the standard tube method. Additionally, 120 pairings using pooled sera containing anti-canine erythrocyte antibody at various concentrations were tested with leftover blood from a hospital population to assess sensitivity and specificity of the gel tube method in comparison with the standard method. The gel tube method had a good relative specificity of 96.1% in detecting lack of agglutination (compatibility) compared to the standard tube method. Agreement between the 2 methods was moderate. Nine of 107 pairings showed agglutination/incompatibility on either test, too few to allow reliable calculation of relative sensitivity. Fifty percent of the gel tube method results were difficult to interpret due to sample spreading in the reaction and/or negative control tubes. The RapidVet-H method agreed with the standard cross-match method on compatible samples, but detected incompatibility in some sample pairs that were compatible with the standard method. Evaluation using larger numbers of incompatible pairings is needed to assess diagnostic utility. The gel tube method results were difficult to categorize due to sample spreading. Weak agglutination reactions or other factors such as centrifuge model may be responsible. © 2016 American Society for Veterinary Clinical Pathology.

  10. Therapeutic Drug Monitoring of Asparaginase Activity-Method Comparison of MAAT and AHA Test Used in the International AIEOP-BFM ALL 2009 Trial.

    PubMed

    Lanvers-Kaminsky, Claudia; Rüffer, Andrea; Würthwein, Gudrun; Gerss, Joachim; Zucchetti, Massimo; Ballerini, Andrea; Attarbaschi, Andishe; Smisek, Petr; Nath, Christa; Lee, Samiuela; Elitzur, Sara; Zimmermann, Martin; Möricke, Anja; Schrappe, Martin; Rizzari, Carmelo; Boos, Joachim

    2018-02-01

    In the international AIEOP-BFM ALL 2009 trial, asparaginase (ASE) activity was monitored after each dose of pegylated Escherichia coli ASE (PEG-ASE). Two methods were used: the aspartic acid β-hydroxamate (AHA) test and medac asparaginase activity test (MAAT). As the latter method overestimates PEG-ASE activity because it calibrates using E. coli ASE, method comparison was performed using samples from the AIEOP-BFM ALL 2009 trial. PEG-ASE activities were determined using MAAT and AHA test in 2 sets of samples (first set: 630 samples and second set: 91 samples). Bland-Altman analysis was performed on ratios between MAAT and AHA tests. The mean difference between both methods, limits of agreement, and 95% confidence intervals were calculated and compared for all samples and samples grouped according to the calibration ranges of the MAAT and the AHA test. PEG-ASE activity determined using the MAAT was significantly higher than when determined using the AHA test (P < 0.001; Wilcoxon signed-rank test). Within the calibration range of the MAAT (30-600 U/L), PEG-ASE activities determined using the MAAT were on average 23% higher than PEG-ASE activities determined using the AHA test. This complies with the mean difference reported in the MAAT manual. With PEG-ASE activities >600 U/L, the discrepancies between MAAT and AHA test increased. Above the calibration range of the MAAT (>600 U/L) and the AHA test (>1000 U/L), a mean difference of 42% was determined. Because more than 70% of samples had PEG-ASE activities >600 U/L and required additional sample dilution, an overall mean difference of 37% was calculated for all samples (37% for the first and 34% for the second set). Comparison of the MAAT and AHA test for PEG-ASE activity confirmed a mean difference of 23% between MAAT and AHA test for PEG-ASE activities between 30 and 600 U/L. The discrepancy increased in samples with >600 U/L PEG-ASE activity, which will be especially relevant when evaluating high PEG-ASE activities in relation to toxicity, efficacy, and population pharmacokinetics.

  11. Lessons learned in preparing method 29 filters for compliance testing audits.

    PubMed

    Martz, R F; McCartney, J E; Bursey, J T; Riley, C E

    2000-01-01

    Companies conducting compliance testing are required to analyze audit samples at the time they collect and analyze the stack samples if audit samples are available. Eastern Research Group (ERG) provides technical support to the EPA's Emission Measurements Center's Stationary Source Audit Program (SSAP) for developing, preparing, and distributing performance evaluation samples and audit materials. These audit samples are requested via the regulatory Agency and include spiked audit materials for EPA Method 29-Metals Emissions from Stationary Sources, as well as other methods. To provide appropriate audit materials to federal, state, tribal, and local governments, as well as agencies performing environmental activities and conducting emission compliance tests, ERG has recently performed testing of blank filter materials and preparation of spiked filters for EPA Method 29. For sampling stationary sources using an EPA Method 29 sampling train, the use of filters without organic binders containing less than 1.3 microg/in.2 of each of the metals to be measured is required. Risk Assessment testing imposes even stricter requirements for clean filter background levels. Three vendor sources of quartz fiber filters were evaluated for background contamination to ensure that audit samples would be prepared using filters with the lowest metal background levels. A procedure was developed to test new filters, and a cleaning procedure was evaluated to see if a greater level of cleanliness could be achieved using an acid rinse with new filters. Background levels for filters supplied by different vendors and within lots of filters from the same vendor showed a wide variation, confirmed through contact with several analytical laboratories that frequently perform EPA Method 29 analyses. It has been necessary to repeat more than one compliance test because of suspect metals background contamination levels. An acid cleaning step produced improvement in contamination level, but the difference was not significant for most of the Method 29 target metals. As a result of our studies, we conclude: Filters for Method 29 testing should be purchased in lots as large as possible. Testing firms should pre-screen new boxes and/or new lots of filters used for Method 29 testing. Random analysis of three filters (top, middle, bottom of the box) from a new box of vendor filters before allowing them to be used in field tests is a prudent approach. A box of filters from a given vendor should be screened, and filters from this screened box should be used both for testing and as field blanks in each test scenario to provide the level of quality assurance required for stationary source testing.

  12. Reveal Salmonella 2.0 test for detection of Salmonella spp. in foods and environmental samples. Performance Tested Method 960801.

    PubMed

    Hoerner, Rebecca; Feldpausch, Jill; Gray, R Lucas; Curry, Stephanie; Islam, Zahidul; Goldy, Tim; Klein, Frank; Tadese, Theodros; Rice, Jennifer; Mozola, Mark

    2011-01-01

    Reveal Salmonella 2.0 is an improved version of the original Reveal Salmonella lateral flow immunoassay and is applicable to the detection of Salmonella enterica serogroups A-E in a variety of food and environmental samples. A Performance Tested Method validation study was conducted to compare performance of the Reveal 2.0 method with that of the U.S. Department of Agriculture-Food Safety and Inspection Service or U.S. Food and Drug Administration/Bacteriological Analytical Manual reference culture methods for detection of Salmonella spp. in chicken carcass rinse, raw ground turkey, raw ground beef, hot dogs, raw shrimp, a ready-to-eat meal product, dry pet food, ice cream, spinach, cantaloupe, peanut butter, stainless steel surface, and sprout irrigation water. In a total of 17 trials performed internally and four trials performed in an independent laboratory, there were no statistically significant differences in performance of the Reveal 2.0 and reference culture procedures as determined by Chi-square analysis, with the exception of one trial with stainless steel surface and one trial with sprout irrigation water where there were significantly more positive results by the Reveal 2.0 method. Considering all data generated in testing food samples using enrichment procedures specifically designed for the Reveal method, overall sensitivity of the Reveal method relative to the reference culture methods was 99%. In testing environmental samples, sensitivity of the Reveal method relative to the reference culture method was 164%. For select foods, use of the Reveal test in conjunction with reference method enrichment resulted in overall sensitivity of 92%. There were no unconfirmed positive results on uninoculated control samples in any trials for specificity of 100%. In inclusivity testing, 102 different Salmonella serovars belonging to serogroups A-E were tested and 99 were consistently positive in the Reveal test. In exclusivity testing of 33 strains of non-salmonellae representing 14 genera, 32 were negative when tested with Reveal following nonselective enrichment, and the remaining strain was found to be substantially inhibited by the enrichment media used with the Reveal method. Results of ruggedness testing showed that the Reveal test produces accurate results even with substantial deviation in sample volume or device development time.

  13. AFNOR validation of Premi Test, a microbiological-based screening tube-test for the detection of antimicrobial residues in animal muscle tissue.

    PubMed

    Gaudin, Valerie; Juhel-Gaugain, Murielle; Morétain, Jean-Pierre; Sanders, Pascal

    2008-12-01

    Premi Test contains viable spores of a strain of Bacillus stearothermophilus which is sensitive to antimicrobial residues, such as beta-lactams, tetracyclines, macrolides and sulphonamides. The growth of the strain is inhibited by the presence of antimicrobial residues in muscle tissue samples. Premi Test was validated according to AFNOR rules (French Association for Normalisation). The AFNOR validation was based on the comparison of reference methods (French Official method, i.e. four plate test (FPT) and the STAR protocol (five plate test)) with the alternative method (Premi Test). A preliminary study was conducted in an expert laboratory (Community Reference Laboratory, CRL) on both spiked and incurred samples (field samples). Several method performance criteria (sensitivity, specificity, relative accuracy) were estimated and are discussed, in addition to detection capabilities. Adequate agreement was found between the alternative method and the reference methods. However, Premi Test was more sensitive to beta-lactams and sulphonamides than the FPT. Subsequently, a collaborative study with 11 laboratories was organised by the CRL. Blank and spiked meat juice samples were sent to participants. The expert laboratory (CRL) statistically analysed the results. It was concluded that Premi Test could be used for the routine determination of antimicrobial residues in muscle of different animal origin with acceptable analytical performance. The detection capabilities of Premi Test for beta-lactams (amoxicillin, ceftiofur), one macrolide (tylosin) and tetracycline were at the level of the respective maximum residue limits (MRL) in muscle samples or even lower.

  14. Improved ASTM G72 Test Method for Ensuring Adequate Fuel-to-Oxidizer Ratios

    NASA Technical Reports Server (NTRS)

    Juarez, Alfredo; Harper, Susana A.

    2016-01-01

    The ASTM G72/G72M-15 Standard Test Method for Autogenous Ignition Temperature of Liquids and Solids in a High-Pressure Oxygen-Enriched Environment is currently used to evaluate materials for the ignition susceptibility driven by exposure to external heat in an enriched oxygen environment. Testing performed on highly volatile liquids such as cleaning solvents has proven problematic due to inconsistent test results (non-ignitions). Non-ignition results can be misinterpreted as favorable oxygen compatibility, although they are more likely associated with inadequate fuel-to-oxidizer ratios. Forced evaporation during purging and inadequate sample size were identified as two potential causes for inadequate available sample material during testing. In an effort to maintain adequate fuel-to-oxidizer ratios within the reaction vessel during test, several parameters were considered, including sample size, pretest sample chilling, pretest purging, and test pressure. Tests on a variety of solvents exhibiting a range of volatilities are presented in this paper. A proposed improvement to the standard test protocol as a result of this evaluation is also presented. Execution of the final proposed improved test protocol outlines an incremental step method of determining optimal conditions using increased sample sizes while considering test system safety limits. The proposed improved test method increases confidence in results obtained by utilizing the ASTM G72 autogenous ignition temperature test method and can aid in the oxygen compatibility assessment of highly volatile liquids and other conditions that may lead to false non-ignition results.

  15. Analysis of small sample size studies using nonparametric bootstrap test with pooled resampling method.

    PubMed

    Dwivedi, Alok Kumar; Mallawaarachchi, Indika; Alvarado, Luis A

    2017-06-30

    Experimental studies in biomedical research frequently pose analytical problems related to small sample size. In such studies, there are conflicting findings regarding the choice of parametric and nonparametric analysis, especially with non-normal data. In such instances, some methodologists questioned the validity of parametric tests and suggested nonparametric tests. In contrast, other methodologists found nonparametric tests to be too conservative and less powerful and thus preferred using parametric tests. Some researchers have recommended using a bootstrap test; however, this method also has small sample size limitation. We used a pooled method in nonparametric bootstrap test that may overcome the problem related with small samples in hypothesis testing. The present study compared nonparametric bootstrap test with pooled resampling method corresponding to parametric, nonparametric, and permutation tests through extensive simulations under various conditions and using real data examples. The nonparametric pooled bootstrap t-test provided equal or greater power for comparing two means as compared with unpaired t-test, Welch t-test, Wilcoxon rank sum test, and permutation test while maintaining type I error probability for any conditions except for Cauchy and extreme variable lognormal distributions. In such cases, we suggest using an exact Wilcoxon rank sum test. Nonparametric bootstrap paired t-test also provided better performance than other alternatives. Nonparametric bootstrap test provided benefit over exact Kruskal-Wallis test. We suggest using nonparametric bootstrap test with pooled resampling method for comparing paired or unpaired means and for validating the one way analysis of variance test results for non-normal data in small sample size studies. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  16. A comparison of fitness-case sampling methods for genetic programming

    NASA Astrophysics Data System (ADS)

    Martínez, Yuliana; Naredo, Enrique; Trujillo, Leonardo; Legrand, Pierrick; López, Uriel

    2017-11-01

    Genetic programming (GP) is an evolutionary computation paradigm for automatic program induction. GP has produced impressive results but it still needs to overcome some practical limitations, particularly its high computational cost, overfitting and excessive code growth. Recently, many researchers have proposed fitness-case sampling methods to overcome some of these problems, with mixed results in several limited tests. This paper presents an extensive comparative study of four fitness-case sampling methods, namely: Interleaved Sampling, Random Interleaved Sampling, Lexicase Selection and Keep-Worst Interleaved Sampling. The algorithms are compared on 11 symbolic regression problems and 11 supervised classification problems, using 10 synthetic benchmarks and 12 real-world data-sets. They are evaluated based on test performance, overfitting and average program size, comparing them with a standard GP search. Comparisons are carried out using non-parametric multigroup tests and post hoc pairwise statistical tests. The experimental results suggest that fitness-case sampling methods are particularly useful for difficult real-world symbolic regression problems, improving performance, reducing overfitting and limiting code growth. On the other hand, it seems that fitness-case sampling cannot improve upon GP performance when considering supervised binary classification.

  17. Validation of the 3M molecular detection system for the detection of listeria in meat, seafood, dairy, and retail environments.

    PubMed

    Fortes, Esther D; David, John; Koeritzer, Bob; Wiedmann, Martin

    2013-05-01

    There is a continued need to develop improved rapid methods for detection of foodborne pathogens. The aim of this project was to evaluate the 3M Molecular Detection System (3M MDS), which uses isothermal DNA amplification, and the 3M Molecular Detection Assay Listeria using environmental samples obtained from retail delicatessens and meat, seafood, and dairy processing plants. Environmental sponge samples were tested for Listeria with the 3M MDS after 22 and 48 h of enrichment in 3M Modified Listeria Recovery Broth (3M mLRB); enrichments were also used for cultural detection of Listeria spp. Among 391 samples tested for Listeria, 74 were positive by both the 3M MDS and the cultural method, 310 were negative by both methods, 2 were positive by the 3M MDS and negative by the cultural method, and one sample was negative by the 3M MDS and positive by the cultural method. Four samples were removed from the sample set, prior to statistical analyses, due to potential cross-contamination during testing. Listeria isolates from positive samples represented L. monocytogenes, L. innocua, L. welshimeri, and L. seeligeri. Overall, the 3M MDS and culture-based detection after enrichment in 3M mLRB did not differ significantly (P < 0.05) with regard to the number of positive samples, when chi-square analyses were performed for (i) number of positive samples after 22 h, (ii) number of positive samples after 48 h, and (iii) number of positive samples after 22 and/or 48 h of enrichment in 3M mLRB. Among 288 sampling sites that were tested with duplicate sponges, 67 each tested positive with the 3M MDS and the traditional U.S. Food and Drug Administration Bacteriological Analytical Manual method, further supporting that the 3M MDS performs equivalently to traditional methods when used with environmental sponge samples.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tripathi, Ashish; McNulty, Ian; Munson, Todd

    We propose a new approach to robustly retrieve the exit wave of an extended sample from its coherent diffraction pattern by exploiting sparsity of the sample's edges. This approach enables imaging of an extended sample with a single view, without ptychography. We introduce nonlinear optimization methods that promote sparsity, and we derive update rules to robustly recover the sample's exit wave. We test these methods on simulated samples by varying the sparsity of the edge-detected representation of the exit wave. Finally, our tests illustrate the strengths and limitations of the proposed method in imaging extended samples.

  19. Experimental Design for a Sponge-Wipe Study to Relate the Recovery Efficiency and False Negative Rate to the Concentration of a Bacillus anthracis Surrogate for Six Surface Materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Piepel, Gregory F.; Amidan, Brett G.; Krauter, Paula

    2011-05-01

    Two concerns were raised by the Government Accountability Office following the 2001 building contaminations via letters containing Bacillus anthracis (BA). These included the: 1) lack of validated sampling methods, and 2) need to use statistical sampling to quantify the confidence of no contamination when all samples have negative results. Critical to addressing these concerns is quantifying the false negative rate (FNR). The FNR may depend on the 1) method of contaminant deposition, 2) surface concentration of the contaminant, 3) surface material being sampled, 4) sample collection method, 5) sample storage/transportation conditions, 6) sample processing method, and 7) sample analytical method.more » A review of the literature found 17 laboratory studies that focused on swab, wipe, or vacuum samples collected from a variety of surface materials contaminated by BA or a surrogate, and used culture methods to determine the surface contaminant concentration. These studies quantified performance of the sampling and analysis methods in terms of recovery efficiency (RE) and not FNR (which left a major gap in available information). Quantifying the FNR under a variety of conditions is a key aspect of validating sample and analysis methods, and also for calculating the confidence in characterization or clearance decisions based on a statistical sampling plan. A laboratory study was planned to partially fill the gap in FNR results. This report documents the experimental design developed by Pacific Northwest National Laboratory and Sandia National Laboratories (SNL) for a sponge-wipe method. The testing was performed by SNL and is now completed. The study investigated the effects on key response variables from six surface materials contaminated with eight surface concentrations of a BA surrogate (Bacillus atrophaeus). The key response variables include measures of the contamination on test coupons of surface materials tested, contamination recovered from coupons by sponge-wipe samples, RE, and FNR. The experimental design involves 16 test runs, performed in two blocks of eight runs. Three surface materials (stainless steel, vinyl tile, and ceramic tile) were tested in the first block, while three other surface materials (plastic, painted wood paneling, and faux leather) were tested in the second block. The eight surface concentrations of the surrogate were randomly assigned to test runs within each block. Some of the concentrations were very low and presented challenges for deposition, sampling, and analysis. However, such tests are needed to investigate RE and FNR over the full range of concentrations of interest. In each run, there were 10 test coupons of each of the three surface materials. A positive control sample was generated at the same time as each test sample. The positive control results will be used to 1) calculate RE values for the wipe sampling and analysis method, and 2) fit RE- and FNR-concentration equations, for each of the six surface materials. Data analyses will support 1) estimating the FNR for each combination of contaminant concentration and surface material, 2) estimating the surface concentrations and their uncertainties of the contaminant for each combination of concentration and surface material, 3) estimating RE (%) and their uncertainties for each combination of contaminant concentration and surface material, 4) fitting FNR-concentration and RE-concentration equations for each of the six surface materials, 5) assessing goodness-of-fit of the equations, and 6) quantifying the uncertainty in FNR and RE predictions made with the fitted equations.« less

  20. DuPont Qualicon BAX System polymerase chain reaction assay. Performance Tested Method 100201.

    PubMed

    Tice, George; Andaloro, Bridget; Fallon, Dawn; Wallace, F Morgan

    2009-01-01

    A recent outbreak of Salmonella in peanut butter has highlighted the need for validation of rapid detection methods. A multilaboratory study for detecting Salmonella in peanut butter was conducted as part of the AOAC Research Institute Emergency Response Validation program for methods that detect outbreak threats to food safety. Three sites tested spiked samples from the same master mix according to the U.S. Food and Drug Administration's Bacteriological Analytical Manual (FDA-BAM) method and the BAX System method. Salmonella Typhimurium (ATCC 14028) was grown in brain heart infusion for 24 h at 37 degrees C, then diluted to appropriate levels for sample inoculation. Master samples of peanut butter were spiked at high and low target levels, mixed, and allowed to equilibrate at room temperature for 2 weeks. Spike levels were low [1.08 most probable number (MPN)/25 g]; high (11.5 MPN/25 g) and unspiked to serve as negative controls. Each master sample was divided into 25 g portions and coded to blind the samples. Twenty portions of each spiked master sample and five portions of the unspiked sample were tested at each site. At each testing site, samples were blended in 25 g portions with 225 mL prewarmed lactose broth until thoroughly homogenized, then allowed to remain at room temperature for 55-65 min. Samples were adjusted to a pH of 6.8 +/- 0.2, if necessary, and incubated for 22-26 h at 35 degrees C. Across the three reporting laboratories, the BAX System detected Salmonella in 10/60 low-spike samples and 58/60 high-spike samples. The reference FDA-BAM method yielded positive results for 11/60 low-spike and 58/60 high-spike samples. Neither method demonstrated positive results for any of the 15 unspiked samples.

  1. A novel method for single sample multi-axial nanoindentation of hydrated heterogeneous tissues based on testing great white shark jaws.

    PubMed

    Ferrara, Toni L; Boughton, Philip; Slavich, Eve; Wroe, Stephen

    2013-01-01

    Nanomechanical testing methods that are suitable for a range of hydrated tissues are crucial for understanding biological systems. Nanoindentation of tissues can provide valuable insights into biology, tissue engineering and biomimetic design. However, testing hydrated biological samples still remains a significant challenge. Shark jaw cartilage is an ideal substrate for developing a method to test hydrated tissues because it is a unique heterogeneous composite of both mineralized (hard) and non-mineralized (soft) layers and possesses a jaw geometry that is challenging to test mechanically. The aim of this study is to develop a novel method for obtaining multidirectional nanomechanical properties for both layers of jaw cartilage from a single sample, taken from the great white shark (Carcharodon carcharias). A method for obtaining multidirectional data from a single sample is necessary for examining tissue mechanics in this shark because it is a protected species and hence samples may be difficult to obtain. Results show that this method maintains hydration of samples that would otherwise rapidly dehydrate. Our study is the first analysis of nanomechanical properties of great white shark jaw cartilage. Variation in nanomechanical properties were detected in different orthogonal directions for both layers of jaw cartilage in this species. The data further suggest that the mineralized layer of shark jaw cartilage is less stiff than previously posited. Our method allows multidirectional nanomechanical properties to be obtained from a single, small, hydrated heterogeneous sample. Our technique is therefore suitable for use when specimens are rare, valuable or limited in quantity, such as samples obtained from endangered species or pathological tissues. We also outline a method for tip-to-optic calibration that facilitates nanoindentation of soft biological tissues. Our technique may help address the critical need for a nanomechanical testing method that is applicable to a variety of hydrated biological materials whether soft or hard.

  2. System and method for measuring permeability of materials

    DOEpatents

    Hallman, Jr., Russell Louis; Renner, Michael John

    2013-07-09

    Systems and methods are provided for measuring the permeance of a material. The permeability of the material may also be derived. Systems typically provide a liquid or high concentration fluid bath on one side of a material test sample, and a gas flow across the opposing side of the material test sample. The mass flow rate of permeated fluid as a fraction of the combined mass flow rate of gas and permeated fluid is used to calculate the permeance of the material. The material test sample may be a sheet, a tube, or a solid shape. Operational test conditions may be varied, including concentration of the fluid, temperature of the fluid, strain profile of the material test sample, and differential pressure across the material test sample.

  3. Single-view phase retrieval of an extended sample by exploiting edge detection and sparsity

    DOE PAGES

    Tripathi, Ashish; McNulty, Ian; Munson, Todd; ...

    2016-10-14

    We propose a new approach to robustly retrieve the exit wave of an extended sample from its coherent diffraction pattern by exploiting sparsity of the sample's edges. This approach enables imaging of an extended sample with a single view, without ptychography. We introduce nonlinear optimization methods that promote sparsity, and we derive update rules to robustly recover the sample's exit wave. We test these methods on simulated samples by varying the sparsity of the edge-detected representation of the exit wave. Finally, our tests illustrate the strengths and limitations of the proposed method in imaging extended samples.

  4. A field test of point relascope sampling of down coarse woody material in managed stands in the Acadian Forest

    Treesearch

    John C. Brissette; Mark J. Ducey; Jeffrey H. Gove

    2003-01-01

    We field tested a new method for sampling down coarse woody material (CWM) using an angle gauge and compared it with the more traditional line intersect sampling (LIS) method. Permanent sample locations in stands managed with different silvicultural treatments within the Penobscot Experimental Forest (Maine, USA) were used as the sampling locations. Point relascope...

  5. 10 CFR 430.70 - Enforcement.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...), the Secretary may conduct testing of that covered product under this subpart by means of a test notice... be selected for testing, the method of selecting the test sample, the time at which testing shall be... shall select a batch, a batch sample, and test units from the batch sample in accordance with the...

  6. A Note on Testing Mediated Effects in Structural Equation Models: Reconciling Past and Current Research on the Performance of the Test of Joint Significance

    ERIC Educational Resources Information Center

    Valente, Matthew J.; Gonzalez, Oscar; Miocevic, Milica; MacKinnon, David P.

    2016-01-01

    Methods to assess the significance of mediated effects in education and the social sciences are well studied and fall into two categories: single sample methods and computer-intensive methods. A popular single sample method to detect the significance of the mediated effect is the test of joint significance, and a popular computer-intensive method…

  7. At convenience and systematic random sampling: effects on the prognostic value of nuclear area assessments in breast cancer patients.

    PubMed

    Jannink, I; Bennen, J N; Blaauw, J; van Diest, P J; Baak, J P

    1995-01-01

    This study compares the influence of two different nuclear sampling methods on the prognostic value of assessments of mean and standard deviation of nuclear area (MNA, SDNA) in 191 consecutive invasive breast cancer patients with long term follow up. The first sampling method used was 'at convenience' sampling (ACS); the second, systematic random sampling (SRS). Both sampling methods were tested with a sample size of 50 nuclei (ACS-50 and SRS-50). To determine whether, besides the sampling methods, sample size had impact on prognostic value as well, the SRS method was also tested using a sample size of 100 nuclei (SRS-100). SDNA values were systematically lower for ACS, obviously due to (unconsciously) not including small and large nuclei. Testing prognostic value of a series of cut off points, MNA and SDNA values assessed by the SRS method were prognostically significantly stronger than the values obtained by the ACS method. This was confirmed in Cox regression analysis. For the MNA, the Mantel-Cox p-values from SRS-50 and SRS-100 measurements were not significantly different. However, for the SDNA, SRS-100 yielded significantly lower p-values than SRS-50. In conclusion, compared with the 'at convenience' nuclear sampling method, systematic random sampling of nuclei is not only superior with respect to reproducibility of results, but also provides a better prognostic value in patients with invasive breast cancer.

  8. Salmonella testing of pooled pre-enrichment broth cultures for screening multiple food samples.

    PubMed

    Price, W R; Olsen, R A; Hunter, J E

    1972-04-01

    A method has been described for testing multiple food samples for Salmonella without loss in sensitivity. The method pools multiple pre-enrichment broth cultures into single enrichment broths. The subsequent stages of the Salmonella analysis are not altered. The method was found applicable to several dry food materials including nonfat dry milk, dried egg albumin, cocoa, cottonseed flour, wheat flour, and shredded coconut. As many as 25 pre-enrichment broth cultures were pooled without apparent loss in the sensitivity of Salmonella detection as compared to individual sample analysis. The procedure offers a simple, yet effective, way to increase sample capacity in the Salmonella testing of foods, particularly where a large proportion of samples ordinarily is negative. It also permits small portions of pre-enrichment broth cultures to be retained for subsequent individual analysis if positive tests are found. Salmonella testing of pooled pre-enrichment broths provides increased consumer protection for a given amount of analytical effort as compared to individual sample analysis.

  9. Evaluation of selected static methods used to estimate element mobility, acid-generating and acid-neutralizing potentials associated with geologically diverse mining wastes

    USGS Publications Warehouse

    Hageman, Philip L.; Seal, Robert R.; Diehl, Sharon F.; Piatak, Nadine M.; Lowers, Heather

    2015-01-01

    A comparison study of selected static leaching and acid–base accounting (ABA) methods using a mineralogically diverse set of 12 modern-style, metal mine waste samples was undertaken to understand the relative performance of the various tests. To complement this study, in-depth mineralogical studies were conducted in order to elucidate the relationships between sample mineralogy, weathering features, and leachate and ABA characteristics. In part one of the study, splits of the samples were leached using six commonly used leaching tests including paste pH, the U.S. Geological Survey (USGS) Field Leach Test (FLT) (both 5-min and 18-h agitation), the U.S. Environmental Protection Agency (USEPA) Method 1312 SPLP (both leachate pH 4.2 and leachate pH 5.0), and the USEPA Method 1311 TCLP (leachate pH 4.9). Leachate geochemical trends were compared in order to assess differences, if any, produced by the various leaching procedures. Results showed that the FLT (5-min agitation) was just as effective as the 18-h leaching tests in revealing the leachate geochemical characteristics of the samples. Leaching results also showed that the TCLP leaching test produces inconsistent results when compared to results produced from the other leaching tests. In part two of the study, the ABA was determined on splits of the samples using both well-established traditional static testing methods and a relatively quick, simplified net acid–base accounting (NABA) procedure. Results showed that the traditional methods, while time consuming, provide the most in-depth data on both the acid generating, and acid neutralizing tendencies of the samples. However, the simplified NABA method provided a relatively fast, effective estimation of the net acid–base account of the samples. Overall, this study showed that while most of the well-established methods are useful and effective, the use of a simplified leaching test and the NABA acid–base accounting method provide investigators fast, quantitative tools that can be used to provide rapid, reliable information about the leachability of metals and other constituents of concern, and the acid-generating potential of metal mining waste.

  10. Experimental Design for a Sponge-Wipe Study to Relate the Recovery Efficiency and False Negative Rate to the Concentration of a Bacillus anthracis Surrogate for Six Surface Materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Piepel, Gregory F.; Amidan, Brett G.; Krauter, Paula

    2010-12-16

    Two concerns were raised by the Government Accountability Office following the 2001 building contaminations via letters containing Bacillus anthracis (BA). These included the: 1) lack of validated sampling methods, and 2) need to use statistical sampling to quantify the confidence of no contamination when all samples have negative results. Critical to addressing these concerns is quantifying the probability of correct detection (PCD) (or equivalently the false negative rate FNR = 1 - PCD). The PCD/FNR may depend on the 1) method of contaminant deposition, 2) surface concentration of the contaminant, 3) surface material being sampled, 4) sample collection method, 5)more » sample storage/transportation conditions, 6) sample processing method, and 7) sample analytical method. A review of the literature found 17 laboratory studies that focused on swab, wipe, or vacuum samples collected from a variety of surface materials contaminated by BA or a surrogate, and used culture methods to determine the surface contaminant concentration. These studies quantified performance of the sampling and analysis methods in terms of recovery efficiency (RE) and not PCD/FNR (which left a major gap in available information). Quantifying the PCD/FNR under a variety of conditions is a key aspect of validating sample and analysis methods, and also for calculating the confidence in characterization or clearance decisions based on a statistical sampling plan. A laboratory study was planned to partially fill the gap in PCD/FNR results. This report documents the experimental design developed by Pacific Northwest National Laboratory and Sandia National Laboratories (SNL) for a sponge-wipe method. The study will investigate the effects on key response variables from six surface materials contaminated with eight surface concentrations of a BA surrogate (Bacillus atrophaeus). The key response variables include measures of the contamination on test coupons of surface materials tested, contamination recovered from coupons by sponge-wipe samples, RE, and PCD/FNR. The experimental design involves 16 test runs, to be performed in two blocks of eight runs. Three surface materials (stainless steel, vinyl tile, and ceramic tile) were tested in the first block, while three other surface materials (plastic, painted wood paneling, and faux leather) will be tested in the second block. The eight surface concentrations of the surrogate were randomly assigned to test runs within each block. Some of the concentrations will be very low and may present challenges for deposition, sampling, and analysis. However, such tests are needed to investigate RE and PCD/FNR over the full range of concentrations of interest. In each run, there will be 10 test coupons of each of the three surface materials. A positive control sample will be generated prior to each test sample. The positive control results will be used to 1) calculate RE values for the wipe sampling and analysis method, and 2) fit RE- and PCD-concentration equations, for each of the six surface materials. Data analyses will support 1) estimating the PCD for each combination of contaminant concentration and surface material, 2) estimating the surface concentrations and their uncertainties of the contaminant for each combination of concentration and surface material, 3) estimating RE (%) and their uncertainties for each combination of contaminant concentration and surface material, 4) fitting PCD-concentration and RE-concentration equations for each of the six surface materials, 5) assessing goodness-of-fit of the equations, and 6) quantifying the uncertainty in PCD and RE predictions made with the fitted equations.« less

  11. Usefulness of in-house PCR methods for hepatitis B virus DNA detection.

    PubMed

    Portilho, Moyra Machado; Baptista, Marcia Leite; da Silva, Messias; de Sousa, Paulo Sérgio Fonseca; Lewis-Ximenez, Lia Laura; Lampe, Elisabeth; Villar, Livia Melo

    2015-10-01

    The aim of the present study was to evaluate the performance of three in-house PCR techniques for HBV DNA detection and compare it with commercial quantitative methods to evaluate the usefulness of in-house methods for HBV diagnosis. Three panels of HBsAg reactive sera samples were evaluated: (i) 50 samples were examined using three methods for in-house qualitative PCR and the Cobas Amplicor HBV Monitor Assay; (ii) 87 samples were assayed using in-house semi-nested PCR and the Cobas TaqMan HBV test; (iii) 11 serial samples obtained from 2 HBV-infected individuals were assayed using the Cobas Amplicor HBV test and semi-nested PCR. In panel I, HBV DNA was detected in 44 samples using the Cobas Amplicor HBV test, 42 samples using semi-nested PCR (90% concordance with Cobas Amplicor), 22 samples using PCR for the core gene (63.6% concordance) and 29 samples using single-round PCR for the pre-S/S gene (75% concordance). In panel II, HBV DNA was quantified in 78 of the 87 HBsAg reactive samples using Cobas TaqMan but 52 samples using semi-nested PCR (67.8% concordance). HBV DNA was detected in serial samples until the 17th and 26th week after first donation using in-house semi-nested PCR and the Cobas Amplicor HBV test, respectively. In-house semi-nested PCR presented adequate concordance with commercial methods as an alternative method for HBV molecular diagnosis in low-resource settings. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Approaches of using the beard testing method to obtain complete length distributions of the original samples

    USDA-ARS?s Scientific Manuscript database

    The fiber testing instruments such as HVI can rapidly measure fiber length by testing a tapered fiber beard of the sample. But these instruments that use the beard testing method only report a limited number of fiber length parameters instead of the complete length distribution that is important fo...

  13. Appropriate Statistical Analysis for Two Independent Groups of Likert-Type Data

    ERIC Educational Resources Information Center

    Warachan, Boonyasit

    2011-01-01

    The objective of this research was to determine the robustness and statistical power of three different methods for testing the hypothesis that ordinal samples of five and seven Likert categories come from equal populations. The three methods are the two sample t-test with equal variances, the Mann-Whitney test, and the Kolmogorov-Smirnov test. In…

  14. Evaluating Composite Sampling Methods of Bacillus Spores at Low Concentrations

    PubMed Central

    Hess, Becky M.; Amidan, Brett G.; Anderson, Kevin K.; Hutchison, Janine R.

    2016-01-01

    Restoring all facility operations after the 2001 Amerithrax attacks took years to complete, highlighting the need to reduce remediation time. Some of the most time intensive tasks were environmental sampling and sample analyses. Composite sampling allows disparate samples to be combined, with only a single analysis needed, making it a promising method to reduce response times. We developed a statistical experimental design to test three different composite sampling methods: 1) single medium single pass composite (SM-SPC): a single cellulose sponge samples multiple coupons with a single pass across each coupon; 2) single medium multi-pass composite: a single cellulose sponge samples multiple coupons with multiple passes across each coupon (SM-MPC); and 3) multi-medium post-sample composite (MM-MPC): a single cellulose sponge samples a single surface, and then multiple sponges are combined during sample extraction. Five spore concentrations of Bacillus atrophaeus Nakamura spores were tested; concentrations ranged from 5 to 100 CFU/coupon (0.00775 to 0.155 CFU/cm2). Study variables included four clean surface materials (stainless steel, vinyl tile, ceramic tile, and painted dry wallboard) and three grime coated/dirty materials (stainless steel, vinyl tile, and ceramic tile). Analysis of variance for the clean study showed two significant factors: composite method (p< 0.0001) and coupon material (p = 0.0006). Recovery efficiency (RE) was higher overall using the MM-MPC method compared to the SM-SPC and SM-MPC methods. RE with the MM-MPC method for concentrations tested (10 to 100 CFU/coupon) was similar for ceramic tile, dry wall, and stainless steel for clean materials. RE was lowest for vinyl tile with both composite methods. Statistical tests for the dirty study showed RE was significantly higher for vinyl and stainless steel materials, but lower for ceramic tile. These results suggest post-sample compositing can be used to reduce sample analysis time when responding to a Bacillus anthracis contamination event of clean or dirty surfaces. PMID:27736999

  15. Evaluating Composite Sampling Methods of Bacillus Spores at Low Concentrations.

    PubMed

    Hess, Becky M; Amidan, Brett G; Anderson, Kevin K; Hutchison, Janine R

    2016-01-01

    Restoring all facility operations after the 2001 Amerithrax attacks took years to complete, highlighting the need to reduce remediation time. Some of the most time intensive tasks were environmental sampling and sample analyses. Composite sampling allows disparate samples to be combined, with only a single analysis needed, making it a promising method to reduce response times. We developed a statistical experimental design to test three different composite sampling methods: 1) single medium single pass composite (SM-SPC): a single cellulose sponge samples multiple coupons with a single pass across each coupon; 2) single medium multi-pass composite: a single cellulose sponge samples multiple coupons with multiple passes across each coupon (SM-MPC); and 3) multi-medium post-sample composite (MM-MPC): a single cellulose sponge samples a single surface, and then multiple sponges are combined during sample extraction. Five spore concentrations of Bacillus atrophaeus Nakamura spores were tested; concentrations ranged from 5 to 100 CFU/coupon (0.00775 to 0.155 CFU/cm2). Study variables included four clean surface materials (stainless steel, vinyl tile, ceramic tile, and painted dry wallboard) and three grime coated/dirty materials (stainless steel, vinyl tile, and ceramic tile). Analysis of variance for the clean study showed two significant factors: composite method (p< 0.0001) and coupon material (p = 0.0006). Recovery efficiency (RE) was higher overall using the MM-MPC method compared to the SM-SPC and SM-MPC methods. RE with the MM-MPC method for concentrations tested (10 to 100 CFU/coupon) was similar for ceramic tile, dry wall, and stainless steel for clean materials. RE was lowest for vinyl tile with both composite methods. Statistical tests for the dirty study showed RE was significantly higher for vinyl and stainless steel materials, but lower for ceramic tile. These results suggest post-sample compositing can be used to reduce sample analysis time when responding to a Bacillus anthracis contamination event of clean or dirty surfaces.

  16. Modification of the BAX Salmonella test kit to include a hot start functionality (modification of AOAC Official Method 2003.09).

    PubMed

    Wallace, F Morgan; DiCosimo, Deana; Farnum, Andrew; Tice, George; Andaloro, Bridget; Davis, Eugene; Burns, Frank R

    2011-01-01

    In 2010, the BAX System PCR assay for Salmonella was modified to include a hot start functionality designed to keep the reaction enzyme inactive until PCR begins. To validate the assay's Official Methods of Analysis status to include this procedure modification, an evaluation was conducted on four food types that were simultaneously analyzed with the BAX System and either the U.S. Food and Drug Administration's Bacteriological Analytical Manual or the U.S. Department of Agriculture-Food Safety and Inspection Service Microbiology Laboratory Guidebook reference method for detecting Salmonella. Identical performance between the BAX System method and the reference methods was observed. Additionally, lysates were analyzed using both the BAX System Classic and BAX System Q7 instruments with identical results using both platforms for all samples tested. Of the 100 samples analyzed, 34 samples were positive for both the BAX System and reference methods, and 66 samples were negative by both the BAX System and reference methods, demonstrating 100% correlation. No instrument platform variation was observed. Additional inclusivity and exclusivity testing using the modified test kit demonstrated the test kit to be 100% accurate in evaluation of test panels of 352 Salmonella strains and 46 non-Salmonella strains.

  17. The PneuCarriage Project: A Multi-Centre Comparative Study to Identify the Best Serotyping Methods for Examining Pneumococcal Carriage in Vaccine Evaluation Studies

    PubMed Central

    Satzke, Catherine; Dunne, Eileen M.; Porter, Barbara D.; Klugman, Keith P.; Mulholland, E. Kim

    2015-01-01

    Background The pneumococcus is a diverse pathogen whose primary niche is the nasopharynx. Over 90 different serotypes exist, and nasopharyngeal carriage of multiple serotypes is common. Understanding pneumococcal carriage is essential for evaluating the impact of pneumococcal vaccines. Traditional serotyping methods are cumbersome and insufficient for detecting multiple serotype carriage, and there are few data comparing the new methods that have been developed over the past decade. We established the PneuCarriage project, a large, international multi-centre study dedicated to the identification of the best pneumococcal serotyping methods for carriage studies. Methods and Findings Reference sample sets were distributed to 15 research groups for blinded testing. Twenty pneumococcal serotyping methods were used to test 81 laboratory-prepared (spiked) samples. The five top-performing methods were used to test 260 nasopharyngeal (field) samples collected from children in six high-burden countries. Sensitivity and positive predictive value (PPV) were determined for the test methods and the reference method (traditional serotyping of >100 colonies from each sample). For the alternate serotyping methods, the overall sensitivity ranged from 1% to 99% (reference method 98%), and PPV from 8% to 100% (reference method 100%), when testing the spiked samples. Fifteen methods had ≥70% sensitivity to detect the dominant (major) serotype, whilst only eight methods had ≥70% sensitivity to detect minor serotypes. For the field samples, the overall sensitivity ranged from 74.2% to 95.8% (reference method 93.8%), and PPV from 82.2% to 96.4% (reference method 99.6%). The microarray had the highest sensitivity (95.8%) and high PPV (93.7%). The major limitation of this study is that not all of the available alternative serotyping methods were included. Conclusions Most methods were able to detect the dominant serotype in a sample, but many performed poorly in detecting the minor serotype populations. Microarray with a culture amplification step was the top-performing method. Results from this comprehensive evaluation will inform future vaccine evaluation and impact studies, particularly in low-income settings, where pneumococcal disease burden remains high. PMID:26575033

  18. Performing a urine dipstick test with a clean-catch urine sample is an accurate screening method for urinary tract infections in young infants.

    PubMed

    Herreros, María Luisa; Tagarro, Alfredo; García-Pose, Araceli; Sánchez, Aida; Cañete, Alfonso; Gili, Pablo

    2018-01-01

    This study evaluated using urine dipstick tests with the clean-catch method to screen for urinary tract infection (UTI) in febrile infants under 90 days of age. We carried out a comparative diagnostic accuracy study of infants under 90 days old, who were studied for unexplained fever without any source, in the emergency room of a hospital in Madrid from January 2011 to January 2013. We obtained matched samples of urine using two different methods: a clean-catch, standardised stimulation technique and catheterisation collection. The results of the leucocyte esterase test and nitrite test were compared with their urine cultures. We obtained 60 pairs of matched samples. A combined analysis of leukocyte esterase and, or, nitrites yielded a sensitivity of 86% and a specificity of 80% for the diagnosis of UTIs in clean-catch samples. The sensitivity of leukocyte esterase and, or, nitrites in samples obtained by catheterisation were not statistically different to the clean-catch samples (p = 0.592). Performing urine dipstick tests using urine samples obtained by the clean-catch method was an accurate screening test for diagnosing UTIs in febrile infants of less than 90 days old. This provided a good alternative to bladder catheterisation when screening for UTIs. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  19. The PneuCarriage Project: A Multi-Centre Comparative Study to Identify the Best Serotyping Methods for Examining Pneumococcal Carriage in Vaccine Evaluation Studies.

    PubMed

    Satzke, Catherine; Dunne, Eileen M; Porter, Barbara D; Klugman, Keith P; Mulholland, E Kim

    2015-11-01

    The pneumococcus is a diverse pathogen whose primary niche is the nasopharynx. Over 90 different serotypes exist, and nasopharyngeal carriage of multiple serotypes is common. Understanding pneumococcal carriage is essential for evaluating the impact of pneumococcal vaccines. Traditional serotyping methods are cumbersome and insufficient for detecting multiple serotype carriage, and there are few data comparing the new methods that have been developed over the past decade. We established the PneuCarriage project, a large, international multi-centre study dedicated to the identification of the best pneumococcal serotyping methods for carriage studies. Reference sample sets were distributed to 15 research groups for blinded testing. Twenty pneumococcal serotyping methods were used to test 81 laboratory-prepared (spiked) samples. The five top-performing methods were used to test 260 nasopharyngeal (field) samples collected from children in six high-burden countries. Sensitivity and positive predictive value (PPV) were determined for the test methods and the reference method (traditional serotyping of >100 colonies from each sample). For the alternate serotyping methods, the overall sensitivity ranged from 1% to 99% (reference method 98%), and PPV from 8% to 100% (reference method 100%), when testing the spiked samples. Fifteen methods had ≥70% sensitivity to detect the dominant (major) serotype, whilst only eight methods had ≥70% sensitivity to detect minor serotypes. For the field samples, the overall sensitivity ranged from 74.2% to 95.8% (reference method 93.8%), and PPV from 82.2% to 96.4% (reference method 99.6%). The microarray had the highest sensitivity (95.8%) and high PPV (93.7%). The major limitation of this study is that not all of the available alternative serotyping methods were included. Most methods were able to detect the dominant serotype in a sample, but many performed poorly in detecting the minor serotype populations. Microarray with a culture amplification step was the top-performing method. Results from this comprehensive evaluation will inform future vaccine evaluation and impact studies, particularly in low-income settings, where pneumococcal disease burden remains high.

  20. A "three-in-one" sample preparation method for simultaneous determination of B-group water-soluble vitamins in infant formula using VitaFast(®) kits.

    PubMed

    Zhang, Heng; Lan, Fang; Shi, Yupeng; Wan, Zhi-Gang; Yue, Zhen-Feng; Fan, Fang; Lin, Yan-Kui; Tang, Mu-Jin; Lv, Jing-Zhang; Xiao, Tan; Yi, Changqing

    2014-06-15

    VitaFast(®) test kits designed for the microbiological assay in microtiter plate format can be applied to quantitative determination of B-group water-soluble vitamins such as vitamin B12, folic acid and biotin, et al. Compared to traditional microbiological methods, VitaFast(®) kits significantly reduce sample processing time and provide greater reliability, higher productivity and better accuracy. Recently, simultaneous determination of vitamin B12, folic acid and biotin in one sample is urgently required when evaluating the quality of infant formulae in our practical work. However, the present sample preparation protocols which are developed for individual test systems, are incompatible with simultaneous determination of several analytes. To solve this problem, a novel "three-in-one" sample preparation method is herein developed for simultaneous determination of B-group water-soluble vitamins using VitaFast(®) kits. The performance of this novel "three-in-one" sample preparation method was systematically evaluated through comparing with individual sample preparation protocols. The experimental results of the assays which employed "three-in-one" sample preparation method were in good agreement with those obtained from conventional VitaFast(®) extraction methods, indicating that the proposed "three-in-one" sample preparation method is applicable to the present three VitaFast(®) vitamin test systems, thus offering a promising alternative for the three independent sample preparation methods. The proposed new sample preparation method will significantly improve the efficiency of infant formulae inspection. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Validated Test Method 5030C: Purge-and-Trap for Aqueous Samples

    EPA Pesticide Factsheets

    This method describes a purge-and-trap procedure for the analysis of volatile organic compoundsin aqueous samples & water miscible liquid samples. It also describes the analysis of high concentration soil and waste sample extracts prepared in Method 5035.

  2. Method and apparatus for testing surface characteristics of a material

    NASA Technical Reports Server (NTRS)

    Johnson, David L. (Inventor); Kersker, Karl D. (Inventor); Stratton, Troy C. (Inventor); Richardson, David E. (Inventor)

    2006-01-01

    A method, apparatus and system for testing characteristics of a material sample is provided. The system includes an apparatus configured to house the material test sample while defining a sealed volume against a surface of the material test sample. A source of pressurized fluid is in communication with, and configured to pressurize, the sealed volume. A load applying apparatus is configured to apply a defined load to the material sample while the sealed volume is monitored for leakage of the pressurized fluid. Thus, the inducement of surface defects such as microcracking and crazing may be detected and their effects analyzed for a given material. The material test samples may include laminar structures formed of, for example, carbon cloth phenolic, glass cloth phenolic, silica cloth phenolic materials or carbon-carbon materials. In one embodiment the system may be configured to analyze the material test sample while an across-ply loading is applied thereto.

  3. Density-based empirical likelihood procedures for testing symmetry of data distributions and K-sample comparisons.

    PubMed

    Vexler, Albert; Tanajian, Hovig; Hutson, Alan D

    In practice, parametric likelihood-ratio techniques are powerful statistical tools. In this article, we propose and examine novel and simple distribution-free test statistics that efficiently approximate parametric likelihood ratios to analyze and compare distributions of K groups of observations. Using the density-based empirical likelihood methodology, we develop a Stata package that applies to a test for symmetry of data distributions and compares K -sample distributions. Recognizing that recent statistical software packages do not sufficiently address K -sample nonparametric comparisons of data distributions, we propose a new Stata command, vxdbel, to execute exact density-based empirical likelihood-ratio tests using K samples. To calculate p -values of the proposed tests, we use the following methods: 1) a classical technique based on Monte Carlo p -value evaluations; 2) an interpolation technique based on tabulated critical values; and 3) a new hybrid technique that combines methods 1 and 2. The third, cutting-edge method is shown to be very efficient in the context of exact-test p -value computations. This Bayesian-type method considers tabulated critical values as prior information and Monte Carlo generations of test statistic values as data used to depict the likelihood function. In this case, a nonparametric Bayesian method is proposed to compute critical values of exact tests.

  4. A multiplex PCR method for detection of Aspergillus spp. and Mycobacterium tuberculosis in BAL specimens.

    PubMed

    Amini, F; Kachuei, R; Noorbakhsh, F; Imani Fooladi, A A

    2015-06-01

    The aim of this study was the detection of Aspergillus species and Mycobacterium tuberculosis together in bronchoalveolar lavage (BAL) using of multiplex PCR. In this study, from September 2012 until June 2013, 100 bronchoalveolar lavage (BAL) specimens were collected from patients suspected of tuberculosis (TB). After the direct and culture test, multiplex PCR were utilized in order to diagnose Aspergillus species and M. tuberculosis. Phenol-chloroform manual method was used in order to extract DNA from these microorganisms. Aspergillus specific primers, M. tuberculosis designed primers and beta actin primers were used for multiplex PCR. In this study, by multiplex PCR method, Aspergillus species were identified in 12 samples (12%), positive samples in direct and culture test were respectively 11% and 10%. Sensitivity and specificity of this method in comparison to direct test were respectively 100% and 98.8%, also sensitivity and specificity of this method in comparison to culture test were respectively 100% and 97.7%. In this assay, M. tuberculosis was identified in 8 samples (8%). Mycobacterium-positive samples in molecular method, direct and culture test were respectively 6%, 5% and 7%. Sensitivity and specificity of PCR method in comparison to direct test were 80% and 97.8% also sensitivity and specificity of this method in comparison to culture test was 71.4% and 98.9%. In the present study, multiplex PCR method had higher sensitivity than direct and culture test in order to identify and detect Aspergillus, also this method had lower sensitivity for identification of M. tuberculosis, suggesting that the method of DNA extraction was not suitable. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  5. Method and apparatus for processing a test sample to concentrate an analyte in the sample from a solvent in the sample

    DOEpatents

    Turner, Terry D.; Beller, Laurence S.; Clark, Michael L.; Klingler, Kerry M.

    1997-01-01

    A method of processing a test sample to concentrate an analyte in the sample from a solvent in the sample includes: a) boiling the test sample containing the analyte and solvent in a boiling chamber to a temperature greater than or equal to the solvent boiling temperature and less than the analyte boiling temperature to form a rising sample vapor mixture; b) passing the sample vapor mixture from the boiling chamber to an elongated primary separation tube, the separation tube having internal sidewalls and a longitudinal axis, the longitudinal axis being angled between vertical and horizontal and thus having an upper region and a lower region; c) collecting the physically transported liquid analyte on the internal sidewalls of the separation tube; and d) flowing the collected analyte along the angled internal sidewalls of the separation tube to and pass the separation tube lower region. The invention also includes passing a turbulence inducing wave through a vapor mixture to separate physically transported liquid second material from vaporized first material. Apparatus are also disclosed for effecting separations. Further disclosed is a fluidically powered liquid test sample withdrawal apparatus for withdrawing a liquid test sample from a test sample container and for cleaning the test sample container.

  6. Method and apparatus for processing a test sample to concentrate an analyte in the sample from a solvent in the sample

    DOEpatents

    Turner, T.D.; Beller, L.S.; Clark, M.L.; Klingler, K.M.

    1997-10-14

    A method of processing a test sample to concentrate an analyte in the sample from a solvent in the sample includes: (a) boiling the test sample containing the analyte and solvent in a boiling chamber to a temperature greater than or equal to the solvent boiling temperature and less than the analyte boiling temperature to form a rising sample vapor mixture; (b) passing the sample vapor mixture from the boiling chamber to an elongated primary separation tube, the separation tube having internal sidewalls and a longitudinal axis, the longitudinal axis being angled between vertical and horizontal and thus having an upper region and a lower region; (c) collecting the physically transported liquid analyte on the internal sidewalls of the separation tube; and (d) flowing the collected analyte along the angled internal sidewalls of the separation tube to and pass the separation tube lower region. The invention also includes passing a turbulence inducing wave through a vapor mixture to separate physically transported liquid second material from vaporized first material. Apparatus is also disclosed for effecting separations. Further disclosed is a fluidically powered liquid test sample withdrawal apparatus for withdrawing a liquid test sample from a test sample container and for cleaning the test sample container. 8 figs.

  7. Random vs. systematic sampling from administrative databases involving human subjects.

    PubMed

    Hagino, C; Lo, R J

    1998-09-01

    Two sampling techniques, simple random sampling (SRS) and systematic sampling (SS), were compared to determine whether they yield similar and accurate distributions for the following four factors: age, gender, geographic location and years in practice. Any point estimate within 7 yr or 7 percentage points of its reference standard (SRS or the entire data set, i.e., the target population) was considered "acceptably similar" to the reference standard. The sampling frame was from the entire membership database of the Canadian Chiropractic Association. The two sampling methods were tested using eight different sample sizes of n (50, 100, 150, 200, 250, 300, 500, 800). From the profile/characteristics, summaries of four known factors [gender, average age, number (%) of chiropractors in each province and years in practice], between- and within-methods chi 2 tests and unpaired t tests were performed to determine whether any of the differences [descriptively greater than 7% or 7 yr] were also statistically significant. The strengths of the agreements between the provincial distributions were quantified by calculating the percent agreements for each (provincial pairwise-comparison methods). Any percent agreement less than 70% was judged to be unacceptable. Our assessments of the two sampling methods (SRS and SS) for the different sample sizes tested suggest that SRS and SS yielded acceptably similar results. Both methods started to yield "correct" sample profiles at approximately the same sample size (n > 200). SS is not only convenient, it can be recommended for sampling from large databases in which the data are listed without any inherent order biases other than alphabetical listing by surname.

  8. Comparison of no-purge and pumped sampling methods for monitoring concentrations of ordnance-related compounds in groundwater, Camp Edwards, Massachusetts Military Reservation, Cape Cod, Massachusetts, 2009-2010

    USGS Publications Warehouse

    Savoie, Jennifer G.; LeBlanc, Denis R.

    2012-01-01

    Field tests were conducted near the Impact Area at Camp Edwards on the Massachusetts Military Reservation, Cape Cod, Massachusetts, to determine the utility of no-purge groundwater sampling for monitoring concentrations of ordnance-related explosive compounds and perchlorate in the sand and gravel aquifer. The no-purge methods included (1) a diffusion sampler constructed of rigid porous polyethylene, (2) a diffusion sampler constructed of regenerated-cellulose membrane, and (3) a tubular grab sampler (bailer) constructed of polyethylene film. In samples from 36 monitoring wells, concentrations of perchlorate (ClO4-), hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX), and octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX), the major contaminants of concern in the Impact Area, in the no-purge samples were compared to concentrations of these compounds in samples collected by low-flow pumped sampling with dedicated bladder pumps. The monitoring wells are constructed of 2- and 2.5-inch-diameter polyvinyl chloride pipe and have approximately 5- to 10-foot-long slotted screens. The no-purge samplers were left in place for 13-64 days to ensure that ambient groundwater flow had flushed the well screen and concentrations in the screen represented water in the adjacent formation. The sampling methods were compared first in six monitoring wells. Concentrations of ClO4-, RDX, and HMX in water samples collected by the three no-purge sampling methods and low-flow pumped sampling were in close agreement for all six monitoring wells. There is no evidence of a systematic bias in the concentration differences among the methods on the basis of type of sampling device, type of contaminant, or order in which the no-purge samplers were tested. A subsequent examination of vertical variations in concentrations of ClO4- in the 10-foot-long screens of six wells by using rigid porous polyethylene diffusion samplers indicated that concentrations in a given well varied by less than 15 percent and the small variations were unlikely to affect the utility of the various sampling methods. The grab sampler was selected for additional tests in 29 of the 36 monitoring wells used during the study. Concentrations of ClO4-, RDX, HMX, and other minor explosive compounds in water samples collected by using a 1-liter grab sampler and low-flow pumped sampling were in close agreement in field tests in the 29 wells. A statistical analysis based on the sign test indicated that there was no bias in the concentration differences between the methods. There also was no evidence for a systematic bias in concentration differences between the methods related to location of the monitoring wells laterally or vertically in the groundwater-flow system. Field tests in five wells also demonstrated that sample collection by using a 2-liter grab sampler and sequential bailing with the 1-liter grab sampler were options for obtaining sufficient sample volume for replicate and spiked quality assurance and control samples. The evidence from the field tests supports the conclusion that diffusion sampling with the rigid porous polyethylene and regenerated-cellulose membranes and grab sampling with the polyethylene-film samplers provide comparable data on the concentrations of ordnance-related compounds in groundwater at the MMR to that obtained by low-flow pumped sampling. These sampling methods are useful methods for monitoring these compounds at the MMR and in similar hydrogeologic environments.

  9. Evaluating Composite Sampling Methods of Bacillus spores at Low Concentrations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hess, Becky M.; Amidan, Brett G.; Anderson, Kevin K.

    Restoring facility operations after the 2001 Amerithrax attacks took over three months to complete, highlighting the need to reduce remediation time. The most time intensive tasks were environmental sampling and sample analyses. Composite sampling allows disparate samples to be combined, with only a single analysis needed, making it a promising method to reduce response times. We developed a statistical experimental design to test three different composite sampling methods: 1) single medium single pass composite: a single cellulose sponge samples multiple coupons; 2) single medium multi-pass composite: a single cellulose sponge is used to sample multiple coupons; and 3) multi-medium post-samplemore » composite: a single cellulose sponge samples a single surface, and then multiple sponges are combined during sample extraction. Five spore concentrations of Bacillus atrophaeus Nakamura spores were tested; concentrations ranged from 5 to 100 CFU/coupon (0.00775 to 0.155CFU/cm2, respectively). Study variables included four clean surface materials (stainless steel, vinyl tile, ceramic tile, and painted wallboard) and three grime coated/dirty materials (stainless steel, vinyl tile, and ceramic tile). Analysis of variance for the clean study showed two significant factors: composite method (p-value < 0.0001) and coupon material (p-value = 0.0008). Recovery efficiency (RE) was higher overall using the post-sample composite (PSC) method compared to single medium composite from both clean and grime coated materials. RE with the PSC method for concentrations tested (10 to 100 CFU/coupon) was similar for ceramic tile, painted wall board, and stainless steel for clean materials. RE was lowest for vinyl tile with both composite methods. Statistical tests for the dirty study showed RE was significantly higher for vinyl and stainless steel materials, but significantly lower for ceramic tile. These results suggest post-sample compositing can be used to reduce sample analysis time when responding to a Bacillus anthracis contamination event of clean or dirty surfaces.« less

  10. 40 CFR 53.63 - Test procedure: Wind tunnel inlet aspiration test.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the sampler inlet opening centered in the sampling zone. To meet the maximum blockage limit of § 53.62(c)(1) or for convenience, part of the test sampler may be positioned external to the wind tunnel... = reference method sampler volumetric flow rate; and t = sampling time. (iii) Remove the reference method...

  11. Setback Test Users Manual (U.S. Army Armament Research, Development and Engineering Center’s Method)

    DTIC Science & Technology

    2011-09-01

    Picatinny Arsenal, New Jersey. This ARDEC setback test method collapses a planer air gap against an explosive sample in a manner to mimic what could...Research, Development and Engineering Center (ARDEC), Picatinny Arsenal, New Jersey setback test collapses a planer air gap against an explosive sample

  12. 7 CFR 58.812 - Methods of sample analysis.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Methods of sample analysis. 58.812 Section 58.812... Procedures § 58.812 Methods of sample analysis. Samples shall be tested according to the applicable methods of laboratory analysis contained in either DA Instruction 918-RL, as issued by the USDA, Agricultural...

  13. 7 CFR 58.245 - Method of sample analysis.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Method of sample analysis. 58.245 Section 58.245... Procedures § 58.245 Method of sample analysis. Samples shall be tested according to the applicable methods of laboratory analysis contained in either DA Instruction 918-RL as issued by the USDA, Agricultural Marketing...

  14. Testing the Self-Efficacy Questionnaire with Korean Children in Institutionalized Care

    ERIC Educational Resources Information Center

    Kim, Youngmi; Kim, Kyeongmo; Lee, Shinhye

    2017-01-01

    Purpose: We tested the reliability and validity of the Self-Efficacy Questionnaire for Children (SEQ-C) in a sample of children living in orphanages in South Korea. Methods: Our study sample consisted of 334 children aged 13-18 obtained using a convenience sampling method. We conducted a confirmatory factor analysis to identify the factor…

  15. Preservation And Processing Methods For Molecular Genetic Detection And Quantification Of Nosema Ceranae

    USDA-ARS?s Scientific Manuscript database

    The prevalence of Nosema ceranae in managed honey bee colonies has increased dramatically in the past 10 – 20 years worldwide. A variety of genetic testing methods for species identification and prevalence are now available. However sample size and preservation method of samples prior to testing hav...

  16. A comparative review of methods for comparing means using partially paired data.

    PubMed

    Guo, Beibei; Yuan, Ying

    2017-06-01

    In medical experiments with the objective of testing the equality of two means, data are often partially paired by design or because of missing data. The partially paired data represent a combination of paired and unpaired observations. In this article, we review and compare nine methods for analyzing partially paired data, including the two-sample t-test, paired t-test, corrected z-test, weighted t-test, pooled t-test, optimal pooled t-test, multiple imputation method, mixed model approach, and the test based on a modified maximum likelihood estimate. We compare the performance of these methods through extensive simulation studies that cover a wide range of scenarios with different effect sizes, sample sizes, and correlations between the paired variables, as well as true underlying distributions. The simulation results suggest that when the sample size is moderate, the test based on the modified maximum likelihood estimator is generally superior to the other approaches when the data is normally distributed and the optimal pooled t-test performs the best when the data is not normally distributed, with well-controlled type I error rates and high statistical power; when the sample size is small, the optimal pooled t-test is to be recommended when both variables have missing data and the paired t-test is to be recommended when only one variable has missing data.

  17. 19 CFR 151.70 - Method of sampling by Customs.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Wool and Hair § 151.70... feasible to obtain a representative general sample of the wool or hair in a sampling unit or to test such a...

  18. 19 CFR 151.70 - Method of sampling by Customs.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Wool and Hair § 151.70... feasible to obtain a representative general sample of the wool or hair in a sampling unit or to test such a...

  19. 19 CFR 151.70 - Method of sampling by Customs.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Wool and Hair § 151.70... feasible to obtain a representative general sample of the wool or hair in a sampling unit or to test such a...

  20. 19 CFR 151.70 - Method of sampling by Customs.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Wool and Hair § 151.70... feasible to obtain a representative general sample of the wool or hair in a sampling unit or to test such a...

  1. 19 CFR 151.70 - Method of sampling by Customs.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Wool and Hair § 151.70... feasible to obtain a representative general sample of the wool or hair in a sampling unit or to test such a...

  2. Methods for flexible sample-size design in clinical trials: Likelihood, weighted, dual test, and promising zone approaches.

    PubMed

    Shih, Weichung Joe; Li, Gang; Wang, Yining

    2016-03-01

    Sample size plays a crucial role in clinical trials. Flexible sample-size designs, as part of the more general category of adaptive designs that utilize interim data, have been a popular topic in recent years. In this paper, we give a comparative review of four related methods for such a design. The likelihood method uses the likelihood ratio test with an adjusted critical value. The weighted method adjusts the test statistic with given weights rather than the critical value. The dual test method requires both the likelihood ratio statistic and the weighted statistic to be greater than the unadjusted critical value. The promising zone approach uses the likelihood ratio statistic with the unadjusted value and other constraints. All four methods preserve the type-I error rate. In this paper we explore their properties and compare their relationships and merits. We show that the sample size rules for the dual test are in conflict with the rules of the promising zone approach. We delineate what is necessary to specify in the study protocol to ensure the validity of the statistical procedure and what can be kept implicit in the protocol so that more flexibility can be attained for confirmatory phase III trials in meeting regulatory requirements. We also prove that under mild conditions, the likelihood ratio test still preserves the type-I error rate when the actual sample size is larger than the re-calculated one. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Restricted random search method based on taboo search in the multiple minima problem

    NASA Astrophysics Data System (ADS)

    Hong, Seung Do; Jhon, Mu Shik

    1997-03-01

    The restricted random search method is proposed as a simple Monte Carlo sampling method to search minima fast in the multiple minima problem. This method is based on taboo search applied recently to continuous test functions. The concept of the taboo region instead of the taboo list is used and therefore the sampling of a region near an old configuration is restricted in this method. This method is applied to 2-dimensional test functions and the argon clusters. This method is found to be a practical and efficient method to search near-global configurations of test functions and the argon clusters.

  4. Analysis of Duplicated Multiple-Samples Rank Data Using the Mack-Skillings Test.

    PubMed

    Carabante, Kennet Mariano; Alonso-Marenco, Jose Ramon; Chokumnoyporn, Napapan; Sriwattana, Sujinda; Prinyawiwatkul, Witoon

    2016-07-01

    Appropriate analysis for duplicated multiple-samples rank data is needed. This study compared analysis of duplicated rank preference data using the Friedman versus Mack-Skillings tests. Panelists (n = 125) ranked twice 2 orange juice sets: different-samples set (100%, 70%, vs. 40% juice) and similar-samples set (100%, 95%, vs. 90%). These 2 sample sets were designed to get contrasting differences in preference. For each sample set, rank sum data were obtained from (1) averaged rank data of each panelist from the 2 replications (n = 125), (2) rank data of all panelists from each of the 2 separate replications (n = 125 each), (3) jointed rank data of all panelists from the 2 replications (n = 125), and (4) rank data of all panelists pooled from the 2 replications (n = 250); rank data (1), (2), and (4) were separately analyzed by the Friedman test, although those from (3) by the Mack-Skillings test. The effect of sample sizes (n = 10 to 125) was evaluated. For the similar-samples set, higher variations in rank data from the 2 replications were observed; therefore, results of the main effects were more inconsistent among methods and sample sizes. Regardless of analysis methods, the larger the sample size, the higher the χ(2) value, the lower the P-value (testing H0 : all samples are not different). Analyzing rank data (2) separately by replication yielded inconsistent conclusions across sample sizes, hence this method is not recommended. The Mack-Skillings test was more sensitive than the Friedman test. Furthermore, it takes into account within-panelist variations and is more appropriate for analyzing duplicated rank data. © 2016 Institute of Food Technologists®

  5. Detection of BRAF V600 Mutations in Melanoma: Evaluation of Concordance between the Cobas® 4800 BRAF V600 Mutation Test and the Methods Used in French National Cancer Institute (INCa) Platforms in a Real-Life Setting

    PubMed Central

    Mourah, Samia; Denis, Marc G.; Narducci, Fabienne Escande; Solassol, Jérôme; Merlin, Jean-Louis; Sabourin, Jean-Christophe; Scoazec, Jean-Yves; Ouafik, L’Houcine; Emile, Jean-François; Heller, Remy; Souvignet, Claude; Bergougnoux, Loïc; Merlio, Jean-Philippe

    2015-01-01

    Vemurafenib is approved for the treatment of metastatic melanoma in patients with BRAF V600 mutation. In pivotal clinical trials, BRAF testing has always been done with the approved cobas 4800 BRAF test. In routine practice, several methods are available and are used according to the laboratories usual procedures. A national, multicenter, non-interventional study was conducted with prospective and consecutive collection of tumor samples. A parallel evaluation was performed in routine practice between the cobas 4800 BRAF V600 mutation test and home brew methods (HBMs) of 12 national laboratories, labelled and funded by the French National Cancer Institute (INCa). For 420 melanoma samples tested, the cobas method versus HBM showed a high concordance (93.3%; kappa = 0.86) in BRAF V600 genotyping with similar mutation rates (34.0% versus 35.7%, respectively). Overall, 97.4% and 98.6% of samples gave valid results using the cobas and HBM, respectively. Of the 185 samples strictly fulfilling the cobas guidelines, the concordance rate was even higher (95.7%; kappa = 0.91; 95%CI [0.85; 0.97]). Out of the 420 samples tested, 28 (6.7%) showed discordance between HBM and cobas. This prospective study shows a high concordance rate between the cobas 4800 BRAF V600 test and home brew methods in the routine detection of BRAF V600E mutations. PMID:25789737

  6. Sample Containerization and Sealing Techniques for Contamination Prevention and Preservation of Science Value for Mars Sample Return

    NASA Astrophysics Data System (ADS)

    Younse, Paulo

    Four sealing methods for encapsulating samples in 1 cm diameter thin-walled sample tubes were designed, along with a set of tests for characterization and evaluation of contamination prevention and sample preservation capability for the proposed Mars Sample Return (MSR) campaign. The sealing methods include a finned shape memory alloy (SMA) plug, expanding torque plug, contracting SMA ring cap, and expanding SMA ring plug. Mechanical strength and hermeticity of the seal were measured using a helium leak detector. Robustness of the seal to Mars simulant dust, surface abrasion, and pressure differentials were tested. Survivability tests were run to simulate thermal cycles on Mars, vibration from a Mars Ascent Vehicle (MAV), and shock from Earth Entry Vehicle (EEV) landing. Material compatibility with potential sample minerals and organic molecules were studied to select proper tube and seal materials that would not lead to adverse reactions nor contaminate the sample. Cleaning and sterilization techniques were executed on coupons made from the seal materials to assess compliance with planetary protection and contamination control. Finally, a method to cut a sealed tube for sample removal was designed and tested.

  7. Assessment of real-time PCR method for detection of EGFR mutation using both supernatant and cell pellet of malignant pleural effusion samples from non-small-cell lung cancer patients.

    PubMed

    Shin, Saeam; Kim, Juwon; Kim, Yoonjung; Cho, Sun-Mi; Lee, Kyung-A

    2017-10-26

    EGFR mutation is an emerging biomarker for treatment selection in non-small-cell lung cancer (NSCLC) patients. However, optimal mutation detection is hindered by complications associated with the biopsy procedure, tumor heterogeneity and limited sensitivity of test methodology. In this study, we evaluated the diagnostic utility of real-time PCR using malignant pleural effusion samples. A total of 77 pleural fluid samples from 77 NSCLC patients were tested using the cobas EGFR mutation test (Roche Molecular Systems). Pleural fluid was centrifuged, and separated cell pellets and supernatants were tested in parallel. Results were compared with Sanger sequencing and/or peptide nucleic acid (PNA)-mediated PCR clamping of matched tumor tissue or pleural fluid samples. All samples showed valid real-time PCR results in one or more DNA samples extracted from cell pellets and supernatants. Compared with other molecular methods, the sensitivity of real-time PCR method was 100%. Concordance rate of real-time PCR and Sanger sequencing plus PNA-mediated PCR clamping was 98.7%. We have confirmed that real-time PCR using pleural fluid had a high concordance rate compared to conventional methods, with no failed samples. Our data demonstrated that the parallel real-time PCR testing using supernatant and cell pellet could offer reliable and robust surrogate strategy when tissue is not available.

  8. Comparison of Fecal Collection Methods for Microbiota Studies in Bangladesh

    PubMed Central

    Chen, Jun; Kibriya, Muhammad G.; Chen, Yu; Islam, Tariqul; Eunes, Mahbubul; Ahmed, Alauddin; Naher, Jabun; Rahman, Anisur; Amir, Amnon; Shi, Jianxin; Abnet, Christian C.; Nelson, Heidi; Knight, Rob; Chia, Nicholas; Ahsan, Habibul; Sinha, Rashmi

    2017-01-01

    ABSTRACT To our knowledge, fecal microbiota collection methods have not been evaluated in low- and middle-income countries. Therefore, we evaluated five different fecal sample collection methods for technical reproducibility, stability, and accuracy within the Health Effects of Arsenic Longitudinal Study (HEALS) in Bangladesh. Fifty participants from the HEALS provided fecal samples in the clinic which were aliquoted into no solution, 95% ethanol, RNAlater, postdevelopment fecal occult blood test (FOBT) cards, and fecal immunochemical test (FIT) tubes. Half of the aliquots were frozen immediately at −80°C (day 0) and the remaining samples were left at ambient temperature for 96 h and then frozen (day 4). Intraclass correlation coefficients (ICC) were calculated for the relative abundances of the top three phyla, for two alpha diversity measures, and for four beta diversity measures. The duplicate samples had relatively high ICCs for technical reproducibility at day 0 and day 4 (range, 0.79 to 0.99). The FOBT card and samples preserved in RNAlater and 95% ethanol had the highest ICCs for stability over 4 days. The FIT tube had lower stability measures overall. In comparison to the “gold standard” method using immediately frozen fecal samples with no solution, the ICCs for many of the microbial metrics were low, but the rank order appeared to be preserved as seen by the Spearman correlation. The FOBT cards, 95% ethanol, and RNAlater were effective fecal preservatives. These fecal collection methods are optimal for future cohort studies, particularly in low- and middle-income countries. IMPORTANCE The collection of fecal samples in prospective cohort studies is essential to provide the opportunity to study the effect of the human microbiota on numerous health conditions. However, these collection methods have not been adequately tested in low- and middle-income countries. We present estimates of technical reproducibility, stability at ambient temperature for 4 days, and accuracy comparing a “gold standard” for fecal samples in no solution, 95% ethanol, RNAlater, postdevelopment fecal occult blood test cards, and fecal immunochemical test tubes in a study conducted in Bangladesh. Fecal occult blood test cards and fecal samples stored in 95% ethanol or RNAlater adequately preserve fecal samples in this setting. Therefore, new studies in low- and middle-income countries should include collection of fecal samples using fecal occult blood test cards, 95% ethanol, or RNAlater for prospective cohort studies. PMID:28258145

  9. Development of a testing method for asbestos fibers in treated materials of asbestos containing wastes by transmission electron microscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamamoto, Takashi, E-mail: tyama@nies.go.jp; Kida, Akiko; Noma, Yukio

    Highlights: • A high sensitive and selective testing method for asbestos in treated materials of asbestos containing wastes was developed. • Asbestos can be determined at a limits are a few million fibers per gram and a few μg g{sup −1}. • High temperature melting treatment samples were determined by this method. Asbestos fiber concentration were below the quantitation limit in all samples, and total fiber concentrations were determined as 47–170 × 10{sup 6} g{sup −1}. - Abstract: Appropriate treatment of asbestos-containing wastes is a significant problem. In Japan, the inertization of asbestos-containing wastes based on new treatment processes approvedmore » by the Minister of the Environment is promoted. A highly sensitive method for testing asbestos fibers in inertized materials is required so that these processes can be approved. We developed a method in which fibers from milled treated materials are extracted in water by shaking, and are counted and identified by transmission electron microscopy. Evaluation of this method by using asbestos standards and simulated slag samples confirmed that the quantitation limits are a few million fibers per gram and a few μg/g in a sample of 50 mg per filter. We used this method to assay asbestos fibers in slag samples produced by high-temperature melting of asbestos-containing wastes. Fiber concentrations were below the quantitation limit in all samples, and total fiber concentrations were determined as 47–170 × 10{sup −6} f/g. Because the evaluation of treated materials by TEM is difficult owing to the limited amount of sample observable, this testing method should be used in conjunction with bulk analytical methods for sure evaluation of treated materials.« less

  10. The Bootstrap, the Jackknife, and the Randomization Test: A Sampling Taxonomy.

    PubMed

    Rodgers, J L

    1999-10-01

    A simple sampling taxonomy is defined that shows the differences between and relationships among the bootstrap, the jackknife, and the randomization test. Each method has as its goal the creation of an empirical sampling distribution that can be used to test statistical hypotheses, estimate standard errors, and/or create confidence intervals. Distinctions between the methods can be made based on the sampling approach (with replacement versus without replacement) and the sample size (replacing the whole original sample versus replacing a subset of the original sample). The taxonomy is useful for teaching the goals and purposes of resampling schemes. An extension of the taxonomy implies other possible resampling approaches that have not previously been considered. Univariate and multivariate examples are presented.

  11. Evaluation of an inhouse rapid ELISA test for detection of giardia in domestic sheep (Ovis aries).

    PubMed

    Wilson, Jolaine M; Hankenson, F Claire

    2010-11-01

    Sheep (Ovis aries) are increasingly used at our institution as models of human disease. Within the research environment, routine husbandry and handling of sheep has potential for transmission of zoonotic agents, including Giardia. The prevalence of Giardia in sheep may approach 68%. Classic diagnostic testing involves microscopic examination for fecal cysts or trophozoites; however, limitations of microscopy include time, labor, and potential false-negative results due to intermittent shedding. We wished to determine whether a commercial rapid ELISA used for Giardia detection in dogs and cats could be used in sheep. Fecal samples collected from sheep (n = 93) were tested with a combination of 6 methods: reference laboratory fecal flotation, reference laboratory ELISA, inhouse fecal flotation, and commercially available tests (enzyme immunoassay, direct fluorescence antibody assay, and rapid ELISA). Prevalence of Giardia infection in facility sheep was 11.8% (11 of 93 animals). Of the 11 samples considered positive, 3 were confirmed by multiple testing methods, and 5 were positive by microscopy alone. Inhouse fecal flotation for 8 samples was positive on only 1 of 2 consecutive testing days. The rapid ELISA test exhibited 0% sensitivity for sheep giardiasis. Overall, the examined methods had low sensitivities and low positive predictive values. Despite limitations, microscopic analysis of repeat fecal samples remained the most accurate diagnostic method for ovine giardiasis among the methods tested.

  12. A STANDARDIZED ASSESSMENT METHOD (SAM) FOR RIVERINE MACROINVERTEBRATES

    EPA Science Inventory

    A macroinvertebrate sampling method for large rivers based on desirable characteristics of existing nonwadeable methods was developed and tested. Six sites each were sampled on the Great Miami and Kentucky Rivers, reflecting a human disturbance gradient. Samples were collected ...

  13. CTEPP STANDARD OPERATING PROCEDURE FOR PACKING AND SHIPPING STUDY SAMPLES (SOP-3.11)

    EPA Science Inventory

    This SOP describes the methods for packing and shipping study samples. These methods are for packing and shipping biological and environmental samples. The methods have been tested and used in the previous pilot studies.

  14. Analysis of beta-lactam antibiotics in incurred raw milk by rapid test methods and liquid chromatography coupled with electrospray ionization tandem mass spectrometry.

    PubMed

    Riediker, S; Diserens, J M; Stadler, R H

    2001-09-01

    A recently developed confirmatory LC-MS method has been applied to the quantification of five major beta-lactam antibiotics in suspect raw bovine milk samples that gave a positive response with receptor-based (BetaStar) and rapid microbial inhibitory screen tests (Delvotest SP). In total, 18 presumptive positive raw milk samples were reanalyzed; 16 samples showed traces of antibiotic residues that could be identified and quantified by the LC-MS method, ranging from the limits of confirmation up to 38 microg/kg. Of the positive samples, only five (approximately 30%) were found to be violative of EU maximum residue limits. The most frequently detected antibiotic residues were cloxacillin and penicillin G, the former often in combination with amoxicillin or ampicillin. This study compares the results obtained by the three methods on identical samples and addresses how these relate to certain criteria such as sensitivity and selectivity. Furthermore, the limitations of the LC-MS method and the potential impact of the presence of frequently more than one residue in the same milk sample on the response of the rapid test methods are discussed.

  15. Variations in the detection of anti-PEDV antibodies in serum samples using three diagnostic tests - short communication.

    PubMed

    Plut, Jan; Toplak, Ivan; Štukelj, Marina

    2018-06-01

    Over the last few years several porcine epidemic diarrhoea (PED) outbreaks have been discovered in Europe including the first PED case in Slovenia in January 2015. The aim of this study was to determine when PED virus (PEDV) infection started in Slovenia. Serum samples collected between 2012 and 2016 were tested. Three hundred and seventy-five serum samples were collected from 132 Slovenian small, one-site pig farms. Samples were tested for PEDV antibodies utilising three different serological methods: commercially-available indirect ELISA, in-house blocking ELISA test and Immunoperoxidase Monolayer Assay (IPMA) test. One hundred and seventy (45.33%) tested samples were found positive by the commercially-available ELISA test kit, and 10 (5.68%) of these 170 samples found positive were positive by the in-house blocking ELISA. Only these 10 samples were collected from a farm where clinical signs of PED infection had been observed and PEDV was confirmed by RT-PCR methodology; the other 160 samples were collected randomly. Thirty-two samples with the highest S/P value obtained with the commercial ELISA were all negative with IPMA. Reasons for the high variance in the results obtained remain unclear; more research is required to ensure higher sensitivity and specificity in terms of PEDV antibody tests and other PED diagnostic methods.

  16. 19 CFR 151.83 - Method of sampling.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 19 Customs Duties 2 2010-04-01 2010-04-01 false Method of sampling. 151.83 Section 151.83 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY (CONTINUED) EXAMINATION, SAMPLING, AND TESTING OF MERCHANDISE Cotton § 151.83 Method of sampling. For...

  17. A novel tensile test method to assess texture and gaping in salmon fillets.

    PubMed

    Ashton, Thomas J; Michie, Ian; Johnston, Ian A

    2010-05-01

    A new tensile strength method was developed to quantify the force required to tear a standardized block of Atlantic salmon muscle with the aim of identifying those samples more prone to factory downgrading as a result of softness and fillet gaping. The new method effectively overcomes problems of sample attachment encountered with previous tensile strength tests. The repeatability and sensitivity and predictability of the new technique were evaluated against other common instrumental texture measurement methods. The relationship between sensory assessments of firmness and parameters from the instrumental texture methods was also determined. Data from the new method were shown to have the strongest correlations with gaping severity (r =-0.514, P < 0.001) and the highest level of repeatability of data when analyzing cold-smoked samples. The Warner Bratzler shear method gave the most repeatable data from fresh samples and had the highest correlations between fresh and smoked product from the same fish (r = 0.811, P < 0.001). A hierarchical cluster analysis placed the tensile test in the top cluster, alongside the Warner Bratzler method, demonstrating that it also yields adequate data with respect to these tests. None of the tested sensory analysis attributes showed significant relationships to mechanical tests except fillet firmness, with correlations (r) of 0.42 for cylinder probe maximum force (P = 0.005) and 0.31 for tensile work (P = 0.04). It was concluded that the tensile test method developed provides an important addition to the available tools for mechanical analysis of salmon quality, particularly with respect to the prediction of gaping during factory processing, which is a serious commercial problem. A novel, reliable method of measuring flesh tensile strength in salmon, provides data of relevance to gaping.

  18. Sampling techniques for thrips (Thysanoptera: Thripidae) in preflowering tomato.

    PubMed

    Joost, P Houston; Riley, David G

    2004-08-01

    Sampling techniques for thrips (Thysanoptera: Thripidae) were compared in preflowering tomato plants at the Coastal Plain Experiment Station in Tifton, GA, in 2000 and 2003, to determine the most effective method of determining abundance of thrips on tomato foliage early in the growing season. Three relative sampling techniques, including a standard insect aspirator, a 946-ml beat cup, and an insect vacuum device, were compared for accuracy to an absolute method and to themselves for precision and efficiency of sampling thrips. Thrips counts of all relative sampling methods were highly correlated (R > 0.92) to the absolute method. The aspirator method was the most accurate compared with the absolute sample according to regression analysis in 2000. In 2003, all sampling methods were considered accurate according to Dunnett's test, but thrips numbers were lower and sample variation was greater than in 2000. In 2000, the beat cup method had the lowest relative variation (RV) or best precision, at 1 and 8 d after transplant (DAT). Only the beat cup method had RV values <25 for all sampling dates. In 2003, the beat cup method had the lowest RV value at 15 and 21 DAT. The beat cup method also was the most efficient method for all sample dates in both years. Frankliniella fusca (Pergande) was the most abundant thrips species on the foliage of preflowering tomato in both years of study at this location. Overall, the best thrips sampling technique tested was the beat cup method in terms of precision and sampling efficiency.

  19. Comparison of the statistics of salmonella testing of chilled broiler chicken carcasses by whole carcass rinse and neck skin excision

    USDA-ARS?s Scientific Manuscript database

    Whether a required Salmonella test series is passed or failed depends not only on the presence of the bacteria, but also on the methods for taking samples, the methods for culturing samples, and the statistics associated with the sampling plan. The pass-fail probabilities of the two-class attribute...

  20. 40 CFR 63.547 - Test methods.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 9 2010-07-01 2010-07-01 false Test methods. 63.547 Section 63.547... Hazardous Air Pollutants from Secondary Lead Smelting § 63.547 Test methods. (a) The following test methods...), and 63.545(e): (1) Method 1 shall be used to select the sampling port location and the number of...

  1. 40 CFR 63.547 - Test methods.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 9 2011-07-01 2011-07-01 false Test methods. 63.547 Section 63.547... Hazardous Air Pollutants from Secondary Lead Smelting § 63.547 Test methods. (a) The following test methods...), and 63.545(e): (1) Method 1 shall be used to select the sampling port location and the number of...

  2. A comparison of respondent-driven and venue-based sampling of female sex workers in Liuzhou, China

    PubMed Central

    Weir, Sharon S; Merli, M Giovanna; Li, Jing; Gandhi, Anisha D; Neely, William W; Edwards, Jessie K; Suchindran, Chirayath M; Henderson, Gail E; Chen, Xiang-Sheng

    2012-01-01

    Objectives To compare two methods for sampling female sex workers (FSWs) for bio-behavioural surveillance. We compared the populations of sex workers recruited by the venue-based Priorities for Local AIDS Control Efforts (PLACE) method and a concurrently implemented network-based sampling method, respondent-driven sampling (RDS), in Liuzhou, China. Methods For the PLACE protocol, all female workers at a stratified random sample of venues identified as places where people meet new sexual partners were interviewed and tested for syphilis. Female workers who reported sex work in the past 4 weeks were categorised as FSWs. RDS used peer recruitment and chain referral to obtain a sample of FSWs. Data were collected between October 2009 and January 2010. We compared the socio-demographic characteristics and the percentage with a positive syphilis test of FSWs recruited by PLACE and RDS. Results The prevalence of a positive syphilis test was 24% among FSWs recruited by PLACE and 8.5% among those recruited by RDS and tested (prevalence ratio 3.3; 95% CI 1.5 to 7.2). Socio-demographic characteristics (age, residence and monthly income) also varied by sampling method. PLACE recruited fewer FSWs than RDS (161 vs 583), was more labour-intensive and had difficulty gaining access to some venues. RDS was more likely to recruit from areas near the RDS office and from large low prevalence entertainment venues. Conclusions Surveillance protocols using different sampling methods can obtain different estimates of prevalence and population characteristics. Venue-based and network-based methods each have strengths and limitations reflecting differences in design and assumptions. We recommend that more research be conducted on measuring bias in bio-behavioural surveillance. PMID:23172350

  3. Improvement of sampling plans for Salmonella detection in pooled table eggs by use of real-time PCR.

    PubMed

    Pasquali, Frédérique; De Cesare, Alessandra; Valero, Antonio; Olsen, John Emerdhal; Manfreda, Gerardo

    2014-08-01

    Eggs and egg products have been described as the most critical food vehicles of salmonellosis. The prevalence and level of contamination of Salmonella on table eggs are low, which severely affects the sensitivity of sampling plans applied voluntarily in some European countries, where one to five pools of 10 eggs are tested by the culture based reference method ISO 6579:2004. In the current study we have compared the testing-sensitivity of the reference culture method ISO 6579:2004 and an alternative real-time PCR method on Salmonella contaminated egg-pool of different sizes (4-9 uninfected eggs mixed with one contaminated egg) and contamination levels (10°-10(1), 10(1)-10(2), 10(2)-10(3)CFU/eggshell). Two hundred and seventy samples corresponding to 15 replicates per pool size and inoculum level were tested. At the lowest contamination level real-time PCR detected Salmonella in 40% of contaminated pools vs 12% using ISO 6579. The results were used to estimate the lowest number of sample units needed to be tested in order to have a 95% certainty not falsely to accept a contaminated lot by Monte Carlo simulation. According to this simulation, at least 16 pools of 10 eggs each are needed to be tested by ISO 6579 in order to obtain this confidence level, while the minimum number of pools to be tested was reduced to 8 pools of 9 eggs each, when real-time PCR was applied as analytical method. This result underlines the importance of including analytical methods with higher sensitivity in order to improve the efficiency of sampling and reduce the number of samples to be tested. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Innovative application of the moisture analyzer for determination of dry mass content of processed cheese

    NASA Astrophysics Data System (ADS)

    Kowalska, Małgorzata; Janas, Sławomir; Woźniak, Magdalena

    2018-04-01

    The aim of this work was the presentation of an alternative method of determination of the total dry mass content in processed cheese. The authors claim that the presented method can be used in industry's quality control laboratories for routine testing and for quick in-process control. For the test purposes both reference method of determination of dry mass in processed cheese and moisture analyzer method were used. The tests were carried out for three different kinds of processed cheese. In accordance with the reference method, the sample was placed on a layer of silica sand and dried at the temperature of 102 °C for about 4 h. The moisture analyzer test required method validation, with regard to drying temperature range and mass of the analyzed sample. Optimum drying temperature of 110 °C was determined experimentally. For Hochland cream processed cheese sample, the total dry mass content, obtained using the reference method, was 38.92%, whereas using the moisture analyzer method, it was 38.74%. An average analysis time in case of the moisture analyzer method was 9 min. For the sample of processed cheese with tomatoes, the reference method result was 40.37%, and the alternative method result was 40.67%. For the sample of cream processed cheese with garlic the reference method gave value of 36.88%, and the alternative method, of 37.02%. An average time of those determinations was 16 min. Obtained results confirmed that use of moisture analyzer is effective. Compliant values of dry mass content were obtained for both of the used methods. According to the authors, the fact that the measurement took incomparably less time for moisture analyzer method, is a key criterion of in-process control and final quality control method selection.

  5. EVALUATION OF ARG-1 SAMPLES PREPARED BY CESIUM CARBONATE DISSOLUTION DURING THE ISOLOK SME ACCEPTABILITY TESTING

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Edwards, T.; Hera, K.; Coleman, C.

    2011-12-05

    Evaluation of Defense Waste Processing Facility (DWPF) Chemical Process Cell (CPC) cycle time identified several opportunities to improve the CPC processing time. The Mechanical Systems & Custom Equipment Development (MS&CED) Section of the Savannah River National Laboratory (SRNL) recently completed the evaluation of one of these opportunities - the possibility of using an Isolok sampling valve as an alternative to the Hydragard valve for taking DWPF process samples at the Slurry Mix Evaporator (SME). The use of an Isolok for SME sampling has the potential to improve operability, reduce maintenance time, and decrease CPC cycle time. The SME acceptability testingmore » for the Isolok was requested in Task Technical Request (TTR) HLW-DWPF-TTR-2010-0036 and was conducted as outlined in Task Technical and Quality Assurance Plan (TTQAP) SRNLRP-2011-00145. RW-0333P QA requirements applied to the task, and the results from the investigation were documented in SRNL-STI-2011-00693. Measurement of the chemical composition of study samples was a critical component of the SME acceptability testing of the Isolok. A sampling and analytical plan supported the investigation with the analytical plan directing that the study samples be prepared by a cesium carbonate (Cs{sub 2}CO{sub 3}) fusion dissolution method and analyzed by Inductively Coupled Plasma - Optical Emission Spectroscopy (ICP-OES). The use of the cesium carbonate preparation method for the Isolok testing provided an opportunity for an additional assessment of this dissolution method, which is being investigated as a potential replacement for the two methods (i.e., sodium peroxide fusion and mixed acid dissolution) that have been used at the DWPF for the analysis of SME samples. Earlier testing of the Cs{sub 2}CO{sub 3} method yielded promising results which led to a TTR from Savannah River Remediation, LLC (SRR) to SRNL for additional support and an associated TTQAP to direct the SRNL efforts. A technical report resulting from this work was issued that recommended that the mixed acid method be replaced by the Cs{sub 2}CO{sub 3} method for the measurement of magnesium (Mg), sodium (Na), and zirconium (Zr) with additional testing of the method by DWPF Laboratory being needed before further implementation of the Cs{sub 2}CO{sub 3} method at that laboratory. While the SME acceptability testing of the Isolok does not address any of the open issues remaining after the publication of the recommendation for the replacement of the mixed acid method by the Cs{sub 2}CO{sub 3} method (since those issues are to be addressed by the DWPF Laboratory), the Cs{sub 2}CO{sub 3} testing associated with the Isolok testing does provide additional insight into the performance of the method as conducted by SRNL. The performance is to be investigated by looking to the composition measurement data generated by the samples of a standard glass, the Analytical Reference Glass - 1 (ARG-1), that were prepared by the Cs{sub 2}CO{sub 3} method and included in the SME acceptability testing of the Isolok. The measurements of these samples were presented as part of the study results, but no statistical analysis of these measurements was conducted as part of those results. It is the purpose of this report to provide that analysis, which was supported using JMP Version 7.0.2.« less

  6. Sample size determination for equivalence assessment with multiple endpoints.

    PubMed

    Sun, Anna; Dong, Xiaoyu; Tsong, Yi

    2014-01-01

    Equivalence assessment between a reference and test treatment is often conducted by two one-sided tests (TOST). The corresponding power function and sample size determination can be derived from a joint distribution of the sample mean and sample variance. When an equivalence trial is designed with multiple endpoints, it often involves several sets of two one-sided tests. A naive approach for sample size determination in this case would select the largest sample size required for each endpoint. However, such a method ignores the correlation among endpoints. With the objective to reject all endpoints and when the endpoints are uncorrelated, the power function is the production of all power functions for individual endpoints. With correlated endpoints, the sample size and power should be adjusted for such a correlation. In this article, we propose the exact power function for the equivalence test with multiple endpoints adjusted for correlation under both crossover and parallel designs. We further discuss the differences in sample size for the naive method without and with correlation adjusted methods and illustrate with an in vivo bioequivalence crossover study with area under the curve (AUC) and maximum concentration (Cmax) as the two endpoints.

  7. 9 CFR 149.6 - Slaughter facilities.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... result based on an ELISA method and is confirmed positive by further testing using the digestion method... decertified. (C) If a test sample yields a positive test result based on an ELISA method, but is not confirmed...

  8. 9 CFR 149.6 - Slaughter facilities.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... result based on an ELISA method and is confirmed positive by further testing using the digestion method... decertified. (C) If a test sample yields a positive test result based on an ELISA method, but is not confirmed...

  9. 9 CFR 149.6 - Slaughter facilities.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... result based on an ELISA method and is confirmed positive by further testing using the digestion method... decertified. (C) If a test sample yields a positive test result based on an ELISA method, but is not confirmed...

  10. 9 CFR 149.6 - Slaughter facilities.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... result based on an ELISA method and is confirmed positive by further testing using the digestion method... decertified. (C) If a test sample yields a positive test result based on an ELISA method, but is not confirmed...

  11. 9 CFR 149.6 - Slaughter facilities.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... result based on an ELISA method and is confirmed positive by further testing using the digestion method... decertified. (C) If a test sample yields a positive test result based on an ELISA method, but is not confirmed...

  12. Reveal Listeria 2.0 test for detection of Listeria spp. in foods and environmental samples.

    PubMed

    Alles, Susan; Curry, Stephanie; Almy, David; Jagadeesan, Balamurugan; Rice, Jennifer; Mozola, Mark

    2012-01-01

    A Performance Tested Method validation study was conducted for a new lateral flow immunoassay (Reveal Listeria 2.0) for detection of Listeria spp. in foods and environmental samples. Results of inclusivity testing showed that the test detects all species of Listeria, with the exception of L. grayi. In exclusivity testing conducted under nonselective growth conditions, all non-listeriae tested produced negative Reveal assay results, except for three strains of Lactobacillus spp. However, these lactobacilli are inhibited by the selective Listeria Enrichment Single Step broth enrichment medium used with the Reveal method. Six foods were tested in parallel by the Reveal method and the U.S. Food and Drug Administration/Bacteriological Analytical Manual (FDA/BAM) reference culture procedure. Considering data from both internal and independent laboratory trials, overall sensitivity of the Reveal method relative to that of the FDA/BAM procedure was 101%. Four foods were tested in parallel by the Reveal method and the U.S. Department of Agriculture-Food Safety and Inspection Service (USDA-FSIS) reference culture procedure. Overall sensitivity of the Reveal method relative to that of the USDA-FSIS procedure was 98.2%. There were no statistically significant differences in the number of positives obtained by the Reveal and reference culture procedures in any food trials. In testing of swab or sponge samples from four types of environmental surfaces, sensitivity of Reveal relative to that of the USDA-FSIS reference culture procedure was 127%. For two surface types, differences in the number of positives obtained by the Reveal and reference methods were statistically significant, with more positives by the Reveal method in both cases. Specificity of the Reveal assay was 100%, as there were no unconfirmed positive results obtained in any phase of the testing. Results of ruggedness experiments showed that the Reveal assay is tolerant of modest deviations in test sample volume and device incubation time.

  13. [Evaluation of the diagnostic performance of Xpert MTB/RIF test for the detection of Mycobacterium tuberculosis and rifampin resistance in clinical samples].

    PubMed

    Gürsoy, Nafia Canan; Yakupoğulları, Yusuf; Tekerekoğlu, Mehmet Sait; Otlu, Barış

    2016-04-01

    Rapid and accurate detection of active tuberculosis (TB) cases is one of the most important goal of tuberculosis control programme. For this purpose, new methods are being developed to isolate, serotype and determine the drug resistance of the agent. Xpert MTB/RIF test (CepheidGeneXpert® System, USA) that has been recently developed, is a real-time polymerase chain reaction-based method which detects Mycobacterium tuberculosis complex and resistance of the strain to rifampicin (RIF) from the clinical sample directly within a couple of hours. However, there are not sufficient data about the performance of that test for extrapulmonary samples and pulmonary samples other than sputum. The aims of this study were to investigate the sensitivity, specificity, positive and negative predictive values of Xpert MTB/RIF test in detection of M. tuberculosis and the performance in the determination of rifampicin resistance of the isolates from pulmonary and extrapulmonary clinical samples. A total of 2160 clinical samples, in which 1141 (52.8%) were pulmonary and 1019 (47.2%) were extrapulmonary samples, sent to our laboratory between July 2013 to December 2014, were included in the study. Sixty seven of the evaluated samples (3.1%) were positive with microscopy (acid-fast stain; AFS), 116 samples (5.1%) were positive with culture and 98 samples (4.5%) were positive with Xpert MTB/RIF test. When the culture was considered as the reference method, the sensitivity and specificity of Xpert MTB/RIF test were determined as 73.3% and 99.3%, respectively for all samples; 77.5% and 99.5%, respectively for pulmonary samples and 63.9% and 99.2%, respectively for extrapulmonary samples. Among AFS positive samples, the sensitivity was 100% and specificity was 66.7%; whereas among AFS negative samples those values were 40.4% and 99.4%, respectively. Among all the samples involved in the study, RIF resistance was determined only in three samples with Xpert MTB/ RIF test and that was also proved phenotypically (100% concordance). According to mycobacterial culture results, positive and negative predictive values of Xpert MTB/RIF test were determined as 86.7% and 98.5%, respectively for all samples. Those were determined as 92.5% and 98.3%, respectively for extrapulmonary samples and were determined as 74.2 and 98.7%, respectively for pulmonary samples. According to the results obtained in our study, sensitivity of Xpert MTB/RIF test for extrapulmonary samples was found to be at moderate level; sensitivity of the test was found to be decreased especially in AFS negative samples with less bacilli load. Nonetheless, specificity of Xpert MTB/RIF test to the agent in all samples was found to be extremely high. In our study, although RIF-resistant strains were detected in few of the samples, Xpert MTB/ RIF test could differentiate all resistant and sensitive strains. Additionally, detection of M. tuberculosis and RIF resistance in our laboratory takes approximately 20.96 days with culture, this period decreases to a couple of hours with Xpert MTB/RIF test. Because of the advantages such as being practical, rapid and requiring minimal safety measures, it was concluded that Xpert MTB/RIF test may contribute to rapid diagnosis of TB also in extrapulmonary samples, with the confirmation of culture method.

  14. Validation of a modification to Performance-Tested Method 010403: microwell DNA hybridization assay for detection of Listeria spp. in selected foods and selected environmental surfaces.

    PubMed

    Alles, Susan; Peng, Linda X; Mozola, Mark A

    2009-01-01

    A modification to Performance-Tested Method 010403, GeneQuence Listeria Test (DNAH method), is described. The modified method uses a new media formulation, LESS enrichment broth, in single-step enrichment protocols for both foods and environmental sponge and swab samples. Food samples are enriched for 27-30 h at 30 degrees C, and environmental samples for 24-48 h at 30 degrees C. Implementation of these abbreviated enrichment procedures allows test results to be obtained on a next-day basis. In testing of 14 food types in internal comparative studies with inoculated samples, there were statistically significant differences in method performance between the DNAH method and reference culture procedures for only 2 foods (pasteurized crab meat and lettuce) at the 27 h enrichment time point and for only a single food (pasteurized crab meat) in one trial at the 30 h enrichment time point. Independent laboratory testing with 3 foods showed statistical equivalence between the methods for all foods, and results support the findings of the internal trials. Overall, considering both internal and independent laboratory trials, sensitivity of the DNAH method relative to the reference culture procedures was 90.5%. Results of testing 5 environmental surfaces inoculated with various strains of Listeria spp. showed that the DNAH method was more productive than the reference U.S. Department of Agriculture-Food Safety and Inspection Service (USDA-FSIS) culture procedure for 3 surfaces (stainless steel, plastic, and cast iron), whereas results were statistically equivalent to the reference method for the other 2 surfaces (ceramic tile and sealed concrete). An independent laboratory trial with ceramic tile inoculated with L. monocytogenes confirmed the effectiveness of the DNAH method at the 24 h time point. Overall, sensitivity of the DNAH method at 24 h relative to that of the USDA-FSIS method was 152%. The DNAH method exhibited extremely high specificity, with only 1% false-positive reactions overall.

  15. Automated spectrophotometric bicarbonate analysis in duodenal juice compared to the back titration method.

    PubMed

    Erchinger, Friedemann; Engjom, Trond; Gudbrandsen, Oddrun Anita; Tjora, Erling; Gilja, Odd H; Dimcevski, Georg

    2016-01-01

    We have recently evaluated a short endoscopic secretin test for exocrine pancreatic function. Bicarbonate concentration in duodenal juice is an important parameter in this test. Measurement of bicarbonate by back titration as the gold standard method is time consuming, expensive and technically difficult, thus a simplified method is warranted. We aimed to evaluate an automated spectrophotometric method in samples spanning the effective range of bicarbonate concentrations in duodenal juice. We also evaluated if freezing of samples before analyses would affect its results. Patients routinely examined with short endoscopic secretin test suspected to have decreased pancreatic function of various reasons were included. Bicarbonate in duodenal juice was quantified by back titration and automatic spectrophotometry. Both fresh and thawed samples were analysed spectrophotometrically. 177 samples from 71 patients were analysed. Correlation coefficient of all measurements was r = 0.98 (p < 0.001). Correlation coefficient of fresh versus frozen samples conducted with automatic spectrophotometry (n = 25): r = 0.96 (p < 0.001) CONCLUSIONS: The measurement of bicarbonate in fresh and thawed samples by automatic spectrophotometrical analysis correlates excellent with the back titration gold standard. This is a major simplification of direct pancreas function testing, and allows a wider distribution of bicarbonate testing in duodenal juice. Extreme values for Bicarbonate concentration achieved by the autoanalyser method have to be interpreted with caution. Copyright © 2016 IAP and EPC. Published by Elsevier India Pvt Ltd. All rights reserved.

  16. Exact tests using two correlated binomial variables in contemporary cancer clinical trials.

    PubMed

    Yu, Jihnhee; Kepner, James L; Iyer, Renuka

    2009-12-01

    New therapy strategies for the treatment of cancer are rapidly emerging because of recent technology advances in genetics and molecular biology. Although newer targeted therapies can improve survival without measurable changes in tumor size, clinical trial conduct has remained nearly unchanged. When potentially efficacious therapies are tested, current clinical trial design and analysis methods may not be suitable for detecting therapeutic effects. We propose an exact method with respect to testing cytostatic cancer treatment using correlated bivariate binomial random variables to simultaneously assess two primary outcomes. The method is easy to implement. It does not increase the sample size over that of the univariate exact test and in most cases reduces the sample size required. Sample size calculations are provided for selected designs.

  17. Validation of a modification to Performance-Tested Method 070601: Reveal Listeria Test for detection of Listeria spp. in selected foods and selected environmental samples.

    PubMed

    Alles, Susan; Peng, Linda X; Mozola, Mark A

    2009-01-01

    A modification to Performance-Tested Method (PTM) 070601, Reveal Listeria Test (Reveal), is described. The modified method uses a new media formulation, LESS enrichment broth, in single-step enrichment protocols for both foods and environmental sponge and swab samples. Food samples are enriched for 27-30 h at 30 degrees C and environmental samples for 24-48 h at 30 degrees C. Implementation of these abbreviated enrichment procedures allows test results to be obtained on a next-day basis. In testing of 14 food types in internal comparative studies with inoculated samples, there was a statistically significant difference in performance between the Reveal and reference culture [U.S. Food and Drug Administration's Bacteriological Analytical Manual (FDA/BAM) or U.S. Department of Agriculture-Food Safety and Inspection Service (USDA-FSIS)] methods for only a single food in one trial (pasteurized crab meat) at the 27 h enrichment time point, with more positive results obtained with the FDA/BAM reference method. No foods showed statistically significant differences in method performance at the 30 h time point. Independent laboratory testing of 3 foods again produced a statistically significant difference in results for crab meat at the 27 h time point; otherwise results of the Reveal and reference methods were statistically equivalent. Overall, considering both internal and independent laboratory trials, sensitivity of the Reveal method relative to the reference culture procedures in testing of foods was 85.9% at 27 h and 97.1% at 30 h. Results from 5 environmental surfaces inoculated with various strains of Listeria spp. showed that the Reveal method was more productive than the reference USDA-FSIS culture procedure for 3 surfaces (stainless steel, plastic, and cast iron), whereas results were statistically equivalent to the reference method for the other 2 surfaces (ceramic tile and sealed concrete). An independent laboratory trial with ceramic tile inoculated with L. monocytogenes confirmed the effectiveness of the Reveal method at the 24 h time point. Overall, sensitivity of the Reveal method at 24 h relative to that of the USDA-FSIS method was 153%. The Reveal method exhibited extremely high specificity, with only a single false-positive result in all trials combined for overall specificity of 99.5%.

  18. Sample processing approach for detection of ricin in surface samples.

    PubMed

    Kane, Staci; Shah, Sanjiv; Erler, Anne Marie; Alfaro, Teneile

    2017-12-01

    With several ricin contamination incidents reported over the past decade, rapid and accurate methods are needed for environmental sample analysis, especially after decontamination. A sample processing method was developed for common surface sampling devices to improve the limit of detection and avoid false negative/positive results for ricin analysis. Potential assay interferents from the sample matrix (bleach residue, sample material, wetting buffer), including reference dust, were tested using a Time-Resolved Fluorescence (TRF) immunoassay. Test results suggested that the sample matrix did not cause the elevated background fluorescence sometimes observed when analyzing post-bleach decontamination samples from ricin incidents. Furthermore, sample particulates (80mg/mL Arizona Test Dust) did not enhance background fluorescence or interfere with ricin detection by TRF. These results suggested that high background fluorescence in this immunoassay could be due to labeled antibody quality and/or quantity issues. Centrifugal ultrafiltration devices were evaluated for ricin concentration as a part of sample processing. Up to 30-fold concentration of ricin was observed by the devices, which serve to remove soluble interferents and could function as the front-end sample processing step to other ricin analytical methods. The procedure has the potential to be used with a broader range of environmental sample types and with other potential interferences and to be followed by other ricin analytical methods, although additional verification studies would be required. Published by Elsevier B.V.

  19. InstantLabs Listeria monocytogenes food safety kit. Performance tested method 051304.

    PubMed

    Sharma, Neil; Bambusch, Lauren; Le, Thu; Morey, Amit

    2014-01-01

    The InstantLabs Listeria monocytogenes Food Safety Kit was validated against the International Organization for Standardization (ISO) reference method 11290-1 for the detection of Listeria monocytogenes and other Listeria species. The matrixes (stainless steel, sealed concrete, ice cream, whole milk, cheddar cheese, raw shrimp, hot dogs, deli turkey, and lettuce) were inoculated with approximately 1 CFU/test portion of L. monocytogenes to generate fractional positives (5-15) in 20 inoculated samples. Enrichments were also fractionally inoculated with L. grayii for side-by-side testing of the Listeria Species Food Safety Kit. Stainless steel and sealed concrete samples were validated using 4 x 4" and 1 x 1 " test areas, respectively, and enriched in Buffered Listeria Enrichment Broth (BLEB) at 35 +/- 1degreesC for 22-28 h. All food samples were tested at 25 g and enriched in BLEB at 35 +/- 1 degreesC for 24-28 h. All samples were confirmed using the ISO reference method, regardless of initial screen result. The InstantLabs test method performed as well as or better than the reference method for the detection of L. monocytogenes on stainless steel and sealed concrete and in ice cream, whole milk, cheddar cheese, raw shrimp, hot dogs, deli turkey, and lettuce. Inclusivity and exclusivity testing revealed no false negatives and no false positives among the 50 L. monocytogenes serovars and 30 non-L. monocytogenes species examined. The method was shown to be robust when the enrichment times, volumes for DNA extraction, and heat block times were varied.

  20. InstantLabs Listeria species food safety kit. Performance tested methods 041304.

    PubMed

    Sharma, Neil; Bambusch, Lauren; Le, Thu; Morey, Amit

    2014-01-01

    The InstantLabs Listeria Species Food SafetyKitwas validated against the International Organization for Standardization (ISO) reference method 11290-1 for the detection of Listeria monocytogenes and other Listeria species. The matrixes (stainless steel, sealed concrete, cheddar cheese, raw shrimp, and hot dogs) were inoculated with approximately 1 CFU/test portion of various Listeria species to generate fractional positives (5-15) in 20 inoculated samples. Enrichments were also fractionally inoculated with L. monocytogenes for side-by-side testing of the InstantLabs Listeria monocytogenes Food Safety Kit. Stainless steel and sealed concrete samples were validated using 4 x 4" and 1 x 1" test areas, respectively, and enriched in Buffered Listeria Enrichment Broth (BLEB) at 35 +/- 1 degrees C for 22-28 h. All food samples were tested at 25 g or 25 mL and enriched in BLEB at 35 +/- 1 degrees C for 24-28 h. All samples were confirmed using the ISO reference method, regardless of initial screen result. The InstantLabs test method performed as well as or better than the reference method for the detection of Listeria species on stainless steel, sealed concrete, cheddar cheese, raw shrimp, and hot dogs. Inclusivity and exclusivity testing revealed no false negatives and no false positives among the 80 Listeria species and 30 non-Listeria species examined. The method was shown to be robust when variations were introduced to the enrichment time, the volume for DNA extraction, and the heat block time (data not shown).

  1. Comparison of mine waste assessment methods at the Rattler mine site, Virginia Canyon, Colorado

    USGS Publications Warehouse

    Hageman, Phil L.; Smith, Kathleen S.; Wildeman, Thomas R.; Ranville, James F.

    2005-01-01

    In a joint project, the mine waste-piles at the Rattler Mine near Idaho Springs, Colorado, were sampled and analyzed by scientists from the U.S. Geological Survey (USGS) and the Colorado School of Mines (CSM). Separate sample collection, sample leaching, and leachate analyses were performed by both groups and the results were compared. For the study, both groups used the USGS sampling procedure and the USGS Field Leach Test (FLT). The leachates generated from these tests were analyzed for a suite of elements using ICP-AES (CSM) and ICP-MS (USGS). Leachate geochemical fingerprints produced by the two groups for composites collected from the same mine waste showed good agreement. In another set of tests, CSM collected another set of Rattler mine waste composite samples using the USGS sampling procedure. This set of composite samples was leached using the Colorado Division of Minerals and Geology (CDMG) leach test, and a modified Toxicity Characteristic Leaching Procedure (TCLP) leach test. Leachate geochemical fingerprints produced using these tests showed a variation of more than a factor of two from the geochemical fingerprints produced using the USGS FLT leach test. We have concluded that the variation in the results is due to the different parameters of the leaching tests and not due to the sampling or analytical methods.

  2. Analysis of beryllium and depleted uranium: An overview of detection methods in aerosols and soils

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Camins, I.; Shinn, J.H.

    We conducted a survey of commercially available methods for analysis of beryllium and depleted uranium in aerosols and soils to find a reliable, cost-effective, and sufficiently precise method for researchers involved in environmental testing at the Yuma Proving Ground, Yuma, Arizona. Criteria used for evaluation include cost, method of analysis, specificity, sensitivity, reproducibility, applicability, and commercial availability. We found that atomic absorption spectrometry with graphite furnace meets these criteria for testing samples for beryllium. We found that this method can also be used to test samples for depleted uranium. However, atomic absorption with graphite furnace is not as sensitive amore » measurement method for depleted uranium as it is for beryllium, so we recommend that quality control of depleted uranium analysis be maintained by testing 10 of every 1000 samples by neutron activation analysis. We also evaluated 45 companies and institutions that provide analyses of beryllium and depleted uranium. 5 refs., 1 tab.« less

  3. Romer Labs RapidChek®Listeria monocytogenes Test System for the Detection of L. monocytogenes on Selected Foods and Environmental Surfaces.

    PubMed

    Juck, Gregory; Gonzalez, Verapaz; Allen, Ann-Christine Olsson; Sutzko, Meredith; Seward, Kody; Muldoon, Mark T

    2018-04-27

    The Romer Labs RapidChek ® Listeria monocytogenes test system (Performance Tested Method ℠ 011805) was validated against the U.S. Department of Agriculture-Food Safety and Inspection Service Microbiology Laboratory Guidebook (USDA-FSIS/MLG), U.S. Food and Drug Association Bacteriological Analytical Manual (FDA/BAM), and AOAC Official Methods of Analysis ℠ (AOAC/OMA) cultural reference methods for the detection of L. monocytogenes on selected foods including hot dogs, frozen cooked breaded chicken, frozen cooked shrimp, cured ham, and ice cream, and environmental surfaces including stainless steel and plastic in an unpaired study design. The RapidChek method uses a proprietary enrichment media system, a 44-48 h enrichment at 30 ± 1°C, and detects L. monocytogenes on an immunochromatographic lateral flow device within 10 min. Different L. monocytogenes strains were used to spike each of the matrixes. Samples were confirmed based on the reference method confirmations and an alternate confirmation method. A total of 140 low-level spiked samples were tested by the RapidChek method after enrichment for 44-48 h in parallel with the cultural reference method. There were 88 RapidChek presumptive positives. One of the presumptive positives was not confirmed culturally. Additionally, one of the culturally confirmed samples did not exhibit a presumptive positive. No difference between the alternate confirmation method and reference confirmation method was observed. The respective cultural reference methods (USDA-FSIS/MLG, FDA/BAM, and AOAC/OMA) produced a total of 63 confirmed positive results. Nonspiked samples from all foods were reported as negative for L. monocytogenes by all methods. Probability of detection analysis demonstrated no significant differences in the number of positive samples detected by the RapidChek method and the respective cultural reference method.

  4. A proposal to standardize reporting units for fecal immunochemical tests for hemoglobin.

    PubMed

    Fraser, Callum G; Allison, James E; Halloran, Stephen P; Young, Graeme P

    2012-06-06

    Fecal immunochemical tests for hemoglobin are replacing traditional guaiac fecal occult blood tests in population screening programs for many reasons. However, the many available fecal immunochemical test devices use a range of sampling methods, differ with regard to hemoglobin stability, and report hemoglobin concentrations in different ways. The methods for sampling, the mass of feces collected, and the volume and characteristics of the buffer used in the sampling device also vary among fecal immunochemical tests, making comparisons of test performance characteristics difficult. Fecal immunochemical test results may be expressed as the hemoglobin concentration in the sampling device buffer and, sometimes, albeit rarely, as the hemoglobin concentration per mass of feces. The current lack of consistency in units for reporting hemoglobin concentration is particularly problematic because apparently similar hemoglobin concentrations obtained with different devices can lead to very different clinical interpretations. Consistent adoption of an internationally accepted method for reporting results would facilitate comparisons of outcomes from these tests. We propose a simple strategy for reporting fecal hemoglobin concentration that will facilitate the comparison of results between fecal immunochemical test devices and across clinical studies. Such reporting is readily achieved by defining the mass of feces sampled and the volume of sample buffer (with confidence intervals) and expressing results as micrograms of hemoglobin per gram of feces. We propose that manufacturers of fecal immunochemical tests provide this information and that the authors of research articles, guidelines, and policy articles, as well as pathology services and regulatory bodies, adopt this metric when reporting fecal immunochemical test results.

  5. Credit Building in IDA Programs: Early Findings of a Longitudinal Study

    ERIC Educational Resources Information Center

    Birkenmaier, Julie; Curley, Jami; Kelly, Patrick

    2012-01-01

    Objective: This article reports on the impact of the Individual Development Account (IDA) program on credit. Method: Using a convenience sample of IDA participants (N = 165), data were analyzed using paired sample "t" tests, independent sample "t" test, one-way analysis of variance, Mann-Whitney "U" Tests, and…

  6. Accuracy, precision, usability, and cost of portable silver test methods for ceramic filter factories.

    PubMed

    Meade, Rhiana D; Murray, Anna L; Mittelman, Anjuliee M; Rayner, Justine; Lantagne, Daniele S

    2017-02-01

    Locally manufactured ceramic water filters are one effective household drinking water treatment technology. During manufacturing, silver nanoparticles or silver nitrate are applied to prevent microbiological growth within the filter and increase bacterial removal efficacy. Currently, there is no recommendation for manufacturers to test silver concentrations of application solutions or filtered water. We identified six commercially available silver test strips, kits, and meters, and evaluated them by: (1) measuring in quintuplicate six samples from 100 to 1,000 mg/L (application range) and six samples from 0.0 to 1.0 mg/L (effluent range) of silver nanoparticles and silver nitrate to determine accuracy and precision; (2) conducting volunteer testing to assess ease-of-use; and (3) comparing costs. We found no method accurately detected silver nanoparticles, and accuracy ranged from 4 to 91% measurement error for silver nitrate samples. Most methods were precise, but only one method could test both application and effluent concentration ranges of silver nitrate. Volunteers considered test strip methods easiest. The cost for 100 tests ranged from 36 to 1,600 USD. We found no currently available method accurately and precisely measured both silver types at reasonable cost and ease-of-use, thus these methods are not recommended to manufacturers. We recommend development of field-appropriate methods that accurately and precisely measure silver nanoparticle and silver nitrate concentrations.

  7. Liquid-Based Medium Used to Prepare Cytological Breast Nipple Fluid Improves the Quality of Cellular Samples Automatic Collection

    PubMed Central

    Zonta, Marco Antonio; Velame, Fernanda; Gema, Samara; Filassi, Jose Roberto; Longatto-Filho, Adhemar

    2014-01-01

    Background Breast cancer is the second cause of death in women worldwide. The spontaneous breast nipple discharge may contain cells that can be analyzed for malignancy. Halo® Mamo Cyto Test (HMCT) was recently developed as an automated system indicated to aspirate cells from the breast ducts. The objective of this study was to standardize the methodology of sampling and sample preparation of nipple discharge obtained by the automated method Halo breast test and perform cytological evaluation in samples preserved in liquid medium (SurePath™). Methods We analyzed 564 nipple fluid samples, from women between 20 and 85 years old, without history of breast disease and neoplasia, no pregnancy, and without gynecologic medical history, collected by HMCT method and preserved in two different vials with solutions for transport. Results From 306 nipple fluid samples from method 1, 199 (65%) were classified as unsatisfactory (class 0), 104 (34%) samples were classified as benign findings (class II), and three (1%) were classified as undetermined to neoplastic cells (class III). From 258 samples analyzed in method 2, 127 (49%) were classified as class 0, 124 (48%) were classified as class II, and seven (2%) were classified as class III. Conclusion Our study suggests an improvement in the quality and quantity of cellular samples when the association of the two methodologies is performed, Halo breast test and the method in liquid medium. PMID:29147397

  8. Evaluation of a new automated instrument for pretransfusion testing.

    PubMed

    Morelati, F; Revelli, N; Maffei, L M; Poretti, M; Santoro, C; Parravicini, A; Rebulla, P; Cole, R; Sirchia, G

    1998-10-01

    A number of automated devices for pretransfusion testing have recently become available. This study evaluated a fully automated device based on column agglutination technology (AutoVue System, Ortho, Raritan, NJ). Some 6747 tests including forward and reverse ABO group, Rh type and phenotype, antibody screen, autocontrol, and crossmatch were performed on random samples from 1069 blood donors, 2063 patients, and 98 newborns and cord blood. Also tested were samples from 168 immunized patients and 53 donors expressing weak or variant A and D antigens. Test results and technician times required for their performance were compared with those obtained by standard methods (manual column agglutination technology, slide, semiautomatic handler). No erroneous conclusions were found in regard to the 5028 ABO group and Rh type or phenotype determinations carried out with the device. The device rejected 1.53 percent of tests for sample inadequacy. Of the remaining 18 tests with discrepant results found with the device and not confirmed with the standard methods, 6 gave such results because of mixed-field reactions, 10 gave negative results with A2 RBCs in reverse ABO grouping, and 2 gave very weak positive reactions in antibody screening and crossmatching. In the samples from immunized patients, the device missed one weak anti-K, whereas standard methods missed five weak antibodies. In addition, 48, 34, and 31 of the 53 weak or variant antigens were detected by the device, the slide method, and the semiautomated handler, respectively. Technician time with the standard methods was 1.6 to 7 times higher than that with the device. The technical performance of the device compared favorably with that of standard methods, with a number of advantages, including in particular the saving of technician time. Sample inadequacy was the most common cause of discrepancy, which suggests that standardization of sample collection can further improve the performance of the device.

  9. Validation of the ANSR Listeria method for detection of Listeria spp. in environmental samples.

    PubMed

    Wendorf, Michael; Feldpausch, Emily; Pinkava, Lisa; Luplow, Karen; Hosking, Edan; Norton, Paul; Biswas, Preetha; Mozola, Mark; Rice, Jennifer

    2013-01-01

    ANSR Listeria is a new diagnostic assay for detection of Listeria spp. in sponge or swab samples taken from a variety of environmental surfaces. The method is an isothermal nucleic acid amplification assay based on the nicking enzyme amplification reaction technology. Following single-step sample enrichment for 16-24 h, the assay is completed in 40 min, requiring only simple instrumentation. In inclusivity testing, 48 of 51 Listeria strains tested positive, with only the three strains of L. grayi producing negative results. Further investigation showed that L. grayi is reactive in the ANSR assay, but its ability to grow under the selective enrichment conditions used in the method is variable. In exclusivity testing, 32 species of non-Listeria, Gram-positive bacteria all produced negative ANSR assay results. Performance of the ANSR method was compared to that of the U.S. Department of Agriculture-Food Safety and Inspection Service reference culture procedure for detection of Listeria spp. in sponge or swab samples taken from inoculated stainless steel, plastic, ceramic tile, sealed concrete, and rubber surfaces. Data were analyzed using Chi-square and probability of detection models. Only one surface, stainless steel, showed a significant difference in performance between the methods, with the ANSR method producing more positive results. Results of internal trials were supported by findings from independent laboratory testing. The ANSR Listeria method can be used as an accurate, rapid, and simple alternative to standard culture methods for detection of Listeria spp. in environmental samples.

  10. Differential auger spectrometry

    DOEpatents

    Strongin, Myron; Varma, Matesh Narayan; Anne, Joshi

    1976-06-22

    Differential Auger spectroscopy method for increasing the sensitivity of micro-Auger spectroanalysis of the surfaces of dilute alloys, by alternately periodically switching an electron beam back and forth between an impurity free reference sample and a test sample containing a trace impurity. The Auger electrons from the samples produce representative Auger spectrum signals which cancel to produce an Auger test sample signal corresponding to the amount of the impurity in the test samples.

  11. 43 CFR 11.64 - Injury determination phase-testing and sampling methods.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... paragraphs (b), (c), (d), (e), and (f) of this section. (b) Surface water resources. (1) Testing and sampling for injury to surface water resources shall be performed using methodologies described in the... for surface water resources shall be conducted in accordance with methods that are generally accepted...

  12. 43 CFR 11.64 - Injury determination phase-testing and sampling methods.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... paragraphs (b), (c), (d), (e), and (f) of this section. (b) Surface water resources. (1) Testing and sampling for injury to surface water resources shall be performed using methodologies described in the... for surface water resources shall be conducted in accordance with methods that are generally accepted...

  13. Genetic Stock Identification Of Production Colonies Of Russian Honey Bees

    USDA-ARS?s Scientific Manuscript database

    The prevalence of Nosema ceranae in managed honey bee colonies has increased dramatically in the past 10 – 20 years worldwide. A variety of genetic testing methods for species identification and prevalence are now available. However sample size and preservation method of samples prior to testing hav...

  14. 21 CFR 177.1950 - Vinyl chloride-ethylene copolymers.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... deciliter per gram as determined by ASTM method D1243-79, “Standard Test Method for Dilute Solution... vinyl chloride-ethylene copol-ymer per 100 grams of sample tested as determined from the organic... using duplicate blanks. Approximately 400 grams of sample (accurately weighed) shall be placed in a 2...

  15. 21 CFR 177.1950 - Vinyl chloride-ethylene copolymers.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... deciliter per gram as determined by ASTM method D1243-79, “Standard Test Method for Dilute Solution... vinyl chloride-ethylene copol-ymer per 100 grams of sample tested as determined from the organic... using duplicate blanks. Approximately 400 grams of sample (accurately weighed) shall be placed in a 2...

  16. 40 CFR 61.174 - Test methods and procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Arsenic Emissions From Primary Copper Smelters § 61.174 Test methods and procedures. (a) To determine... converter arsenic charging rate as follows: (1) Collect daily grab samples of copper matte and any lead... determine the weight percent of inorganic arsenic contained in each sample. (3) Calculate the converter...

  17. Generating virtual training samples for sparse representation of face images and face recognition

    NASA Astrophysics Data System (ADS)

    Du, Yong; Wang, Yu

    2016-03-01

    There are many challenges in face recognition. In real-world scenes, images of the same face vary with changing illuminations, different expressions and poses, multiform ornaments, or even altered mental status. Limited available training samples cannot convey these possible changes in the training phase sufficiently, and this has become one of the restrictions to improve the face recognition accuracy. In this article, we view the multiplication of two images of the face as a virtual face image to expand the training set and devise a representation-based method to perform face recognition. The generated virtual samples really reflect some possible appearance and pose variations of the face. By multiplying a training sample with another sample from the same subject, we can strengthen the facial contour feature and greatly suppress the noise. Thus, more human essential information is retained. Also, uncertainty of the training data is simultaneously reduced with the increase of the training samples, which is beneficial for the training phase. The devised representation-based classifier uses both the original and new generated samples to perform the classification. In the classification phase, we first determine K nearest training samples for the current test sample by calculating the Euclidean distances between the test sample and training samples. Then, a linear combination of these selected training samples is used to represent the test sample, and the representation result is used to classify the test sample. The experimental results show that the proposed method outperforms some state-of-the-art face recognition methods.

  18. Appearance-based representative samples refining method for palmprint recognition

    NASA Astrophysics Data System (ADS)

    Wen, Jiajun; Chen, Yan

    2012-07-01

    The sparse representation can deal with the lack of sample problem due to utilizing of all the training samples. However, the discrimination ability will degrade when more training samples are used for representation. We propose a novel appearance-based palmprint recognition method. We aim to find a compromise between the discrimination ability and the lack of sample problem so as to obtain a proper representation scheme. Under the assumption that the test sample can be well represented by a linear combination of a certain number of training samples, we first select the representative training samples according to the contributions of the samples. Then we further refine the training samples by an iteration procedure, excluding the training sample with the least contribution to the test sample for each time. Experiments on PolyU multispectral palmprint database and two-dimensional and three-dimensional palmprint database show that the proposed method outperforms the conventional appearance-based palmprint recognition methods. Moreover, we also explore and find out the principle of the usage for the key parameters in the proposed algorithm, which facilitates to obtain high-recognition accuracy.

  19. [Implication of inverse-probability weighting method in the evaluation of diagnostic test with verification bias].

    PubMed

    Kang, Leni; Zhang, Shaokai; Zhao, Fanghui; Qiao, Youlin

    2014-03-01

    To evaluate and adjust the verification bias existed in the screening or diagnostic tests. Inverse-probability weighting method was used to adjust the sensitivity and specificity of the diagnostic tests, with an example of cervical cancer screening used to introduce the Compare Tests package in R software which could be implemented. Sensitivity and specificity calculated from the traditional method and maximum likelihood estimation method were compared to the results from Inverse-probability weighting method in the random-sampled example. The true sensitivity and specificity of the HPV self-sampling test were 83.53% (95%CI:74.23-89.93)and 85.86% (95%CI: 84.23-87.36). In the analysis of data with randomly missing verification by gold standard, the sensitivity and specificity calculated by traditional method were 90.48% (95%CI:80.74-95.56)and 71.96% (95%CI:68.71-75.00), respectively. The adjusted sensitivity and specificity under the use of Inverse-probability weighting method were 82.25% (95% CI:63.11-92.62) and 85.80% (95% CI: 85.09-86.47), respectively, whereas they were 80.13% (95%CI:66.81-93.46)and 85.80% (95%CI: 84.20-87.41) under the maximum likelihood estimation method. The inverse-probability weighting method could effectively adjust the sensitivity and specificity of a diagnostic test when verification bias existed, especially when complex sampling appeared.

  20. A comprehensive evaluation of various sensitivity analysis methods: A case study with a hydrological model

    DOE PAGES

    Gan, Yanjun; Duan, Qingyun; Gong, Wei; ...

    2014-01-01

    Sensitivity analysis (SA) is a commonly used approach for identifying important parameters that dominate model behaviors. We use a newly developed software package, a Problem Solving environment for Uncertainty Analysis and Design Exploration (PSUADE), to evaluate the effectiveness and efficiency of ten widely used SA methods, including seven qualitative and three quantitative ones. All SA methods are tested using a variety of sampling techniques to screen out the most sensitive (i.e., important) parameters from the insensitive ones. The Sacramento Soil Moisture Accounting (SAC-SMA) model, which has thirteen tunable parameters, is used for illustration. The South Branch Potomac River basin nearmore » Springfield, West Virginia in the U.S. is chosen as the study area. The key findings from this study are: (1) For qualitative SA methods, Correlation Analysis (CA), Regression Analysis (RA), and Gaussian Process (GP) screening methods are shown to be not effective in this example. Morris One-At-a-Time (MOAT) screening is the most efficient, needing only 280 samples to identify the most important parameters, but it is the least robust method. Multivariate Adaptive Regression Splines (MARS), Delta Test (DT) and Sum-Of-Trees (SOT) screening methods need about 400–600 samples for the same purpose. Monte Carlo (MC), Orthogonal Array (OA) and Orthogonal Array based Latin Hypercube (OALH) are appropriate sampling techniques for them; (2) For quantitative SA methods, at least 2777 samples are needed for Fourier Amplitude Sensitivity Test (FAST) to identity parameter main effect. McKay method needs about 360 samples to evaluate the main effect, more than 1000 samples to assess the two-way interaction effect. OALH and LPτ (LPTAU) sampling techniques are more appropriate for McKay method. For the Sobol' method, the minimum samples needed are 1050 to compute the first-order and total sensitivity indices correctly. These comparisons show that qualitative SA methods are more efficient but less accurate and robust than quantitative ones.« less

  1. Diagnostic test accuracy and prevalence inferences based on joint and sequential testing with finite population sampling.

    PubMed

    Su, Chun-Lung; Gardner, Ian A; Johnson, Wesley O

    2004-07-30

    The two-test two-population model, originally formulated by Hui and Walter, for estimation of test accuracy and prevalence estimation assumes conditionally independent tests, constant accuracy across populations and binomial sampling. The binomial assumption is incorrect if all individuals in a population e.g. child-care centre, village in Africa, or a cattle herd are sampled or if the sample size is large relative to population size. In this paper, we develop statistical methods for evaluating diagnostic test accuracy and prevalence estimation based on finite sample data in the absence of a gold standard. Moreover, two tests are often applied simultaneously for the purpose of obtaining a 'joint' testing strategy that has either higher overall sensitivity or specificity than either of the two tests considered singly. Sequential versions of such strategies are often applied in order to reduce the cost of testing. We thus discuss joint (simultaneous and sequential) testing strategies and inference for them. Using the developed methods, we analyse two real and one simulated data sets, and we compare 'hypergeometric' and 'binomial-based' inferences. Our findings indicate that the posterior standard deviations for prevalence (but not sensitivity and specificity) based on finite population sampling tend to be smaller than their counterparts for infinite population sampling. Finally, we make recommendations about how small the sample size should be relative to the population size to warrant use of the binomial model for prevalence estimation. Copyright 2004 John Wiley & Sons, Ltd.

  2. Sample size determination for mediation analysis of longitudinal data.

    PubMed

    Pan, Haitao; Liu, Suyu; Miao, Danmin; Yuan, Ying

    2018-03-27

    Sample size planning for longitudinal data is crucial when designing mediation studies because sufficient statistical power is not only required in grant applications and peer-reviewed publications, but is essential to reliable research results. However, sample size determination is not straightforward for mediation analysis of longitudinal design. To facilitate planning the sample size for longitudinal mediation studies with a multilevel mediation model, this article provides the sample size required to achieve 80% power by simulations under various sizes of the mediation effect, within-subject correlations and numbers of repeated measures. The sample size calculation is based on three commonly used mediation tests: Sobel's method, distribution of product method and the bootstrap method. Among the three methods of testing the mediation effects, Sobel's method required the largest sample size to achieve 80% power. Bootstrapping and the distribution of the product method performed similarly and were more powerful than Sobel's method, as reflected by the relatively smaller sample sizes. For all three methods, the sample size required to achieve 80% power depended on the value of the ICC (i.e., within-subject correlation). A larger value of ICC typically required a larger sample size to achieve 80% power. Simulation results also illustrated the advantage of the longitudinal study design. The sample size tables for most encountered scenarios in practice have also been published for convenient use. Extensive simulations study showed that the distribution of the product method and bootstrapping method have superior performance to the Sobel's method, but the product method was recommended to use in practice in terms of less computation time load compared to the bootstrapping method. A R package has been developed for the product method of sample size determination in mediation longitudinal study design.

  3. A simple micro-photometric method for urinary iodine determination.

    PubMed

    Grimm, Gabriele; Lindorfer, Heidelinde; Kieweg, Heidi; Marculescu, Rodrig; Hoffmann, Martha; Gessl, Alois; Sager, Manfred; Bieglmayer, Christian

    2011-10-01

    Urinary iodide concentration (UIC) is useful to evaluate nutritional iodine status. In clinical settings UIC helps to exclude blocking of the thyroid gland by excessive endogenous iodine, if diagnostic or therapeutic administration of radio-iodine is indicated. Therefore, this study established a simple test for the measurement of UIC. UIC was analyzed in urine samples of 200 patients. Samples were pre-treated at 95°C for 45 min with ammonium persulfate in a thermal cycler, followed by a photometric Sandell-Kolthoff reaction (SK) carried out in microtiter plates. For method comparison, UIC was analyzed in 30 samples by inductivity coupled plasma mass spectro-metry (ICP-MS) as a reference method. Incubation conditions were optimized concerning recovery. The photometric test correlated well to the reference method (SK=0.91*ICP-MS+1, r=0.962) and presented with a functional sensitivity of 20 μg/L. UIC of patient samples ranged from <20 to 750 μg/L (median 110 μg/L); 90% of the urine samples had iodide concentrations below 210 μg/L. The modified SK-test takes approximately 90 min for analyses of 20 urine samples compared with 27 h for ICP-MS. The photometric test provides satisfactory results and can be performed with the basic equipment of a clinical laboratory.

  4. Sample Dimensionality Effects on d' and Proportion of Correct Responses in Discrimination Testing.

    PubMed

    Bloom, David J; Lee, Soo-Yeun

    2016-09-01

    Products in the food and beverage industry have varying levels of dimensionality ranging from pure water to multicomponent food products, which can modify sensory perception and possibly influence discrimination testing results. The objectives of the study were to determine the impact of (1) sample dimensionality and (2) complex formulation changes on the d' and proportion of correct response of the 3-AFC and triangle methods. Two experiments were conducted using 47 prescreened subjects who performed either triangle or 3-AFC test procedures. In Experiment I, subjects performed 3-AFC and triangle tests using model solutions with different levels of dimensionality. Samples increased in dimensionality from 1-dimensional sucrose in water solution to 3-dimensional sucrose, citric acid, and flavor in water solution. In Experiment II, subjects performed 3-AFC and triangle tests using 3-dimensional solutions. Sample pairs differed in all 3 dimensions simultaneously to represent complex formulation changes. Two forms of complexity were compared: dilution, where all dimensions decreased in the same ratio, and compensation, where a dimension was increased to compensate for a reduction in another. The proportion of correct responses decreased for both methods when the dimensionality was increased from 1- to 2-dimensional samples. No reduction in correct responses was observed from 2- to 3-dimensional samples. No significant differences in d' were demonstrated between the 2 methods when samples with complex formulation changes were tested. Results reveal an impact on proportion of correct responses due to sample dimensionality and should be explored further using a wide range of sample formulations. © 2016 Institute of Food Technologists®

  5. Combined target factor analysis and Bayesian soft-classification of interference-contaminated samples: forensic fire debris analysis.

    PubMed

    Williams, Mary R; Sigman, Michael E; Lewis, Jennifer; Pitan, Kelly McHugh

    2012-10-10

    A bayesian soft classification method combined with target factor analysis (TFA) is described and tested for the analysis of fire debris data. The method relies on analysis of the average mass spectrum across the chromatographic profile (i.e., the total ion spectrum, TIS) from multiple samples taken from a single fire scene. A library of TIS from reference ignitable liquids with assigned ASTM classification is used as the target factors in TFA. The class-conditional distributions of correlations between the target and predicted factors for each ASTM class are represented by kernel functions and analyzed by bayesian decision theory. The soft classification approach assists in assessing the probability that ignitable liquid residue from a specific ASTM E1618 class, is present in a set of samples from a single fire scene, even in the presence of unspecified background contributions from pyrolysis products. The method is demonstrated with sample data sets and then tested on laboratory-scale burn data and large-scale field test burns. The overall performance achieved in laboratory and field test of the method is approximately 80% correct classification of fire debris samples. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  6. Comparison of gel column, card, and cartridge techniques for dog erythrocyte antigen 1.1 blood typing

    PubMed Central

    Seth, Mayank; Jackson, Karen V.; Winzelberg, Sarah; Giger, Urs

    2012-01-01

    Objective To compare accuracy and ease of use of a card agglutination assay, an immunochromatographic cartridge method, and a gel-based method for canine blood typing. Sample Blood samples from 52 healthy blood donor dogs, 10 dogs with immune-mediated hemolytic anemia (IMHA), and 29 dogs with other diseases. Procedures Blood samples were tested in accordance with manufacturer guidelines. Samples with low PCVs were created by the addition of autologous plasma to separately assess the effects of anemia on test results. Results Compared with a composite reference standard of agreement between 2 methods, the gel-based method was found to be 100% accurate. The card agglutination assay was 89% to 91% accurate, depending on test interpretation, and the immunochromatographic cartridge method was 93% accurate but 100% specific. Errors were observed more frequently in samples from diseased dogs, particularly those with IMHA. In the presence of persistent autoagglutination, dog erythrocyte antigen (DEA) 1.1 typing was not possible, except with the immunochromatographic cartridge method. Conclusions and Clinical Relevance The card agglutination assay and immunochromatographic cartridge method, performed by trained personnel, were suitable for in-clinic emergency DEA 1.1 blood typing. There may be errors, particularly for samples from dogs with IMHA, and the immunochromatographic cartridge method may have an advantage of allowing typing of samples with persistent autoagglutination. The laboratory gel-based method would be preferred for routine DEA 1.1 typing of donors and patients if it is available and time permits. Current DEA 1.1 typing techniques appear to be appropriately standardized and easy to use. PMID:22280380

  7. Formal Functional Test Designs: Bridging the Gap Between Test Requirements and Test Specifications

    NASA Technical Reports Server (NTRS)

    Hops, Jonathan

    1993-01-01

    This presentation describes the testing life cycle, the purpose of the test design phase, and test design methods and gives an example application. Also included is a description of Test Representation Language (TRL), a summary of the language, and an example of an application of TRL. A sample test requirement and sample test design are included.

  8. Characteristics of the LacTek test as applied to tissue samples: assessment of performance using incurred field samples.

    PubMed

    Mitchell, J M; McNab, W B; Yee, A J; Griffiths, M W; McEwen, S A; Spilsbury, L; Boison, J O

    1998-08-01

    The Lactek test, marketed for antimicrobial residue detection in milk, was validated for the detection of antimicrobial residues in tissues. A previous study found that the LacTek test could confidently identify tissue samples spiked with antimicrobial residues. However, the test could not reliably distinguish violative from nonviolative spiked samples relative to Canadian maximum residue limits (MRLs). The objectives of this study were to assess and compare the performance of the LacTek tests for beta-lactams, tetracyclines, gentamicin, and sulfamethazine on samples containing naturally incurred residues by running the test in parallel with the standard microbial inhibition test (MIT) presently used for the routine testing of tissues at our facility and to assess the agreement with high pressure liquid chromatographic (HPLC) determinative methods. Parallel testing with the official MIT found that the Lactek tests could be confidently used for testing tissue samples containing incurred residues. Among 1,008 MIT-positive samples, the LacTek test found that 90% contained beta-lactams and/or tetracyclines. A further 7.3% of violative residues could not be identified to an antimicrobial class. In addition, 9% of samples testing negative on the MIT were found to contain an antimicrobial residue by the LacTek tests. Comparative testing with HPLC methods found that there was very good agreement between the two tests and that most violations were due to penicillin G and oxytetracycline. Although the LacTek test cannot be used to distinguish violative from nonviolative residue levels, it does offer several advantages over the present MIT. These include speed, ease of use, the ability to identify residues to a specific class, and an improved sensitivity at the MRL level for the most commonly found antimicrobials in tissue.

  9. Roche/BIOTECON Diagnostics LightCycler foodproof L. monocytogenes detection kit in combination with ShortPrep foodproof II Kit. Performance-Tested Method 070401.

    PubMed

    Junge, Benjamin; Berghof-Jäger, Kornelia

    2006-01-01

    A method was developed for the detection of L. monocytogenes in food based on real-time polymerase chain reaction (PCR). This advanced PCR method was designed to reduce the time needed to achieve results from PCR reactions and to enable the user to monitor the amplification of the PCR product simultaneously, in real-time. After DNA isolation using the Roche/BIOTECON Diagnostics ShortPrep foodproof II Kit (formerly called Listeria ShortPrep Kit) designed for the rapid preparation of L. monocytogenes DNA for direct use in PCR, the real-time detection of L. monocytogenes DNA is performed by using the Roche/BIOTECON Diagnostics LightCycler foodproof L. monocytogenes Detection Kit. This kit provides primers and hybridization probes for sequence-specific detection, convenient premixed reagents, and different controls for reliable interpretation of results. For repeatability studies, 20 different foods, covering the 15 food groups recommended from the AOAC Research Institute (AOAC RI) for L. monocytogenes detection were analyzed: raw meats, fresh produce/vegetables, processed meats, seafood, egg and egg products, dairy (cultured/noncultured), spices, dry foods, fruit/juices, uncooked pasta, nuts, confectionery, pet food, food dyes and colorings, and miscellaneous. From each food 20, samples were inoculated with a low level (1-10 colony-forming units (CFU)/25 g) and 20 samples with a high level (10-50 CFU/25 g) of L. monocytogenes. Additionally, 5 uninoculated samples were prepared from each food. The food samples were examined with the test kits and in correlation with the cultural methods according to U.S. Food and Drug Administration (FDA) Bacteriological Analytical Manual (BAM) or U.S. Department of Agriculture (USDA)/Food Safety and Inspection Service (FSIS) Microbiology Laboratory Guidebook. After 48 h of incubation, the PCR method in all cases showed equal or better results than the reference cultural FDA/BAM or USDA/FSIS methods. Fifteen out of 20 tested food types gave exactly the same amount of positive samples for both methods in both inoculation levels. For 5 out of 20 foodstuffs, the PCR method resulted in more positives than the reference method after 48 h of incubation. Following AOAC RI definition, these were false positives because they were not confirmed by the reference method (false-positive rate for low inoculated foodstuffs: 5.4%; for high inoculated foodstuffs: 7.1%). Without calculating these unconfirmed positives, the PCR method showed equal sensitivity results compared to the alternative method. With the unconfirmed PCR-positives included into the calculations, the alternative PCR method showed a higher sensitivity than the microbiological methods (low inoculation level: 100 vs 98.0%; sensitivity rate: 1; high inoculation level: 99.7 vs 97.7%; sensitivity rate, 1). All in-house and independently tested uninoculated food samples were negative for L. monocytogenes. The ruggedness testing of both ShortPrep foodproof II Kit and Roche/BIOTECON LightCycler foodproof L. monocytogenes Detection Kit showed no noteworthy influences to any variation of the parameters component concentration, apparatus comparison, tester comparison, and sample volumes. In total, 102 L. monocytogenes isolates (cultures and pure DNA) were tested and detected for the inclusivity study, including all isolates claimed by the AOAC RI. The exclusivity study included 60 non-L. monocytogenes bacteria. None of the tested isolates gave a false-positive result; specificity was 100%. Three different lots were tested in the lot-to-lot study. All 3 lots gave equal results. The stability study was subdivided into 3 parts: long-term study, stress test, and freeze-defrost test. Three lots were tested in 4 time intervals within a period of 13 months. They all gave comparable results for all test intervals. For the stress test, LightCycler L. monocytogenes detection mixes were stored at different temperatures and tested at different time points during 1 month. Stable results were produced at all storage temperatures. The freeze-defrost analysis showed no noteworthy aggravation of test results. The independent validation study examined by Campden and Chorleywood Food Research Association Group (CCFRA) demonstrated again that the LightCycler L. monocytogenes detection system shows a comparable sensitivity to reference methods. With both the LightCycler PCR and BAM methods, 19 out of 20 inoculated food samples were detected. The 24 h PCR results generated by the LightCycler system corresponded directly with the FDA/BAM culture results. However, the 48 h PCR results did not relate exactly to the FDA/BAM results, as one sample found to be positive by the 48 h PCR could not be culturally confirmed and another sample which was negative by the 48 h PCR was culturally positive.

  10. NASA-STD-6001B Test 1 Upward Flame Propagation; Sample Length Impact on MOC Investigation

    NASA Technical Reports Server (NTRS)

    Harper, Susana Tapia; Juarez, Alfredo; Woods, Brenton L.; Beeson, Harold D.

    2017-01-01

    Understanding the combustion behavior of materials in the elevated oxygen environments of habitable spacecraft is of utmost importance to crew safety and mission success. Currently, certification for unrestricted flight usage of a material with respect to flammability involves passing the Upward Flame Propagation Test of NASA-STD-6001B (Test 1). This test evaluates materials in a standardized test configuration for two failure criteria: self-extinguishment within 15 cm (6 in.) and the propensity of flame propagation by means of flaming material transfer. By the NASA standard, full-length samples are 30 cm (12 in.) in length; however, factors independent of the test method such as limited material availability or various nonstandard test configurations limit the full pretest sample lengths available for test. This paper characterizes the dependence, if any, of pretest sample length on NASA-STD-6001B Test 1 results. Testing was performed using the Maximum Oxygen Concentration (MOC) Threshold Method to obtain a data set for each sample length tested. In addition, various material types, including cloth (Nomex), foam (TA-301) and solids (Ultem), were tested to investigate potential effects of test specimen types. Though additional data needs to be generated to provide statistical confidence, preliminary findings are that use of variable sample lengths has minimal impact on NASA-STD-6001B flammability performance and MOC determination.

  11. 40 CFR Table 3 of Subpart Aaaaaaa... - Test Methods

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 15 2014-07-01 2014-07-01 false Test Methods 3 Table 3 of Subpart..., Subpt. AAAAAAA, Table 3 Table 3 of Subpart AAAAAAA of Part 63—Test Methods For * * * You must use * * * 1. Selecting the sampling locations a and the number of traverse points EPA test method 1 or 1A in...

  12. 40 CFR Table 3 of Subpart Aaaaaaa... - Test Methods

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 15 2012-07-01 2012-07-01 false Test Methods 3 Table 3 of Subpart..., Subpt. AAAAAAA, Table 3 Table 3 of Subpart AAAAAAA of Part 63—Test Methods For * * * You must use * * * 1. Selecting the sampling locations a and the number of traverse points EPA test method 1 or 1A in...

  13. 40 CFR Table 3 of Subpart Aaaaaaa... - Test Methods

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 14 2011-07-01 2011-07-01 false Test Methods 3 Table 3 of Subpart..., Subpt. AAAAAAA, Table 3 Table 3 of Subpart AAAAAAA of Part 63—Test Methods For * * * You must use * * * 1. Selecting the sampling locations a and the number of traverse points EPA test method 1 or 1A in...

  14. 40 CFR Table 3 of Subpart Aaaaaaa... - Test Methods

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 14 2010-07-01 2010-07-01 false Test Methods 3 Table 3 of Subpart..., Subpt. AAAAAAA, Table 3 Table 3 of Subpart AAAAAAA of Part 63—Test Methods For * * * You must use * * * 1. Selecting the sampling locations a and the number of traverse points EPA test method 1 or 1A in...

  15. 40 CFR Table 3 of Subpart Aaaaaaa... - Test Methods

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 15 2013-07-01 2013-07-01 false Test Methods 3 Table 3 of Subpart..., Subpt. AAAAAAA, Table 3 Table 3 of Subpart AAAAAAA of Part 63—Test Methods For * * * You must use * * * 1. Selecting the sampling locations a and the number of traverse points EPA test method 1 or 1A in...

  16. Comparison of analytical methods for the determination of histamine in reference canned fish samples

    NASA Astrophysics Data System (ADS)

    Jakšić, S.; Baloš, M. Ž.; Mihaljev, Ž.; Prodanov Radulović, J.; Nešić, K.

    2017-09-01

    Two screening methods for histamine in canned fish, an enzymatic test and a competitive direct enzyme-linked immunosorbent assay (CD-ELISA), were compared with the reversed-phase liquid chromatography (RP-HPLC) standard method. For enzymatic and CD-ELISA methods, determination was conducted according to producers’ manuals. For RP-HPLC, histamine was derivatized with dansyl-chloride, followed by RP-HPLC and diode array detection. Results of analysis of canned fish, supplied as reference samples for proficiency testing, showed good agreement when histamine was present at higher concentrations (above 100 mg kg-1). At a lower level (16.95 mg kg-1), the enzymatic test produced some higher results. Generally, analysis of four reference samples according to CD-ELISA and RP-HPLC showed good agreement for histamine determination (r=0.977 in concentration range 16.95-216 mg kg-1) The results show that the applied enzymatic test and CD-ELISA appeared to be suitable screening methods for the determination of histamine in canned fish.

  17. Simple Molecular Methods for Early Detection of Chloroquine Drug Resistance in Plasmodium vivax and Plasmodium falciparum

    PubMed Central

    Singh, Raksha; Urhehar, Anant Dattatraya

    2016-01-01

    Introduction Malaria is a human disease of which causes high morbidity and mortality. In Plasmodium falciparum malaria, the resistance to antimalarial drugs, especially chloroquine (CQ) is one of the paramount factors contributing to the global increase in morbidity and mortality, due to malaria. Hence, there is a need for detection of chloroquine drug resistance genes i.e., pfcrt-o (Plasmodium falciparum chloroquine resistance transporter-o) and pfmdr-1 (Plasmodium falciparum multidrug resistance-1) of P. falciparum and pvcrt-o (Plasmodium vivax chloroquine resistance transporter-o) and pvmdr-1 (Plasmodium vivax multidrug resistance-1) of P. vivax by using molecular methods to prevent mortality in malarial cases. Aim To standardize chloroquine drug sensitivity testing by molecular method so as to provide reports of chloroquine within 6-8 hours to physicians for better treatment. Materials and Methods This study was conducted over a period of one year from January to December 2014. A Total of 300 blood samples were collected from malaria suspected patient attending MGM Hospital, Kamothe, Navi Mumbai, India. Out of 300 blood samples, 44 were malaria positive as assessed by Thick and Thin blood smear stained, by Leishman’s method and examination with light microscope. Chloroquine drug sensitivity testing was performed using WHO III plate method (micro test). Nested PCR was done for detection of pfcrt-o and pfmdr-1 for P. falciparum and pvcrt-o, pvmdr-1 genes for P. vivax. Results Total 44 samples were included in this study, out of which 22 samples confirmed for Plasmodium falciparum and 22 samples confirmed for Plasmodium vivax. Out of 22 P. falciparum 15 (68.18%) samples were chloroquine resistant. P. vivax showed chloroquine resistance to 5 samples (22.73%) by method similar to WHO III plate method (micro test) and nested PCR. Conclusion Drug resistance testing by molecular methods is useful for early detection of antimalarial drug resistance. pfmdr-1 along with pfcrt-o can be used as biomarker for chloroquine drug resistance in P. falciparum and pvmdr-1 along with pvcrt-o for P. vivax. PMID:27630842

  18. Standard method of test for grindability of coal by the Hardgrove-machine method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1975-01-01

    A procedure is described for sampling coal, grinding in a Hardgrove grinding machine, and passing through standard sieves to determine the degree of pulverization of coals. The grindability index of the coal tested is calculated from a calibration chart prepared by plotting weight of material passing a No. 200 sieve versus the Hardgrove Grindability Index for the standard reference samples. The Hardgrove machine is shown schematically. The method for preparing and determining grindability indexes of standard reference samples is given in the appendix. (BLM)

  19. Testing of the Defense Waste Processing Facility Cold Chemical Dissolution Method in Sludge Batch 9 Qualification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Edwards, T.; Pareizs, J.; Coleman, C.

    For each sludge batch that is processed in the Defense Waste Processing Facility (DWPF), the Savannah River National Laboratory (SRNL) tests the applicability of the digestion methods used by the DWPF Laboratory for elemental analysis of Sludge Receipt and Adjustment Tank (SRAT) Receipt samples and SRAT Product process control samples. DWPF SRAT samples are typically dissolved using a method referred to as the DWPF Cold Chemical or Cold Chem Method (CC), (see DWPF Procedure SW4- 15.201). Testing indicates that the CC method produced mixed results. The CC method did not result in complete dissolution of either the SRAT Receipt ormore » SRAT Product with some fine, dark solids remaining. However, elemental analyses did not reveal extreme biases for the major elements in the sludge when compared with analyses obtained following dissolution by hot aqua regia (AR) or sodium peroxide fusion (PF) methods. The CC elemental analyses agreed with the AR and PF methods well enough that it should be adequate for routine process control analyses in the DWPF after much more extensive side-by-side tests of the CC method and the PF method are performed on the first 10 SRAT cycles of the Sludge Batch 9 (SB9) campaign. The DWPF Laboratory should continue with their plans for further tests of the CC method during these 10 SRAT cycles.« less

  20. 40 CFR 53.59 - Aerosol transport test for Class I equivalent method samplers.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... sample collection filter) differs significantly from that specified for reference method samplers as... transport is the percentage of a laboratory challenge aerosol which penetrates to the active sample filter of the candidate equivalent method sampler. (2) The active sample filter is the exclusive filter...

  1. 40 CFR 53.59 - Aerosol transport test for Class I equivalent method samplers.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... sample collection filter) differs significantly from that specified for reference method samplers as... transport is the percentage of a laboratory challenge aerosol which penetrates to the active sample filter of the candidate equivalent method sampler. (2) The active sample filter is the exclusive filter...

  2. 40 CFR 53.59 - Aerosol transport test for Class I equivalent method samplers.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... sample collection filter) differs significantly from that specified for reference method samplers as... transport is the percentage of a laboratory challenge aerosol which penetrates to the active sample filter of the candidate equivalent method sampler. (2) The active sample filter is the exclusive filter...

  3. 40 CFR 53.59 - Aerosol transport test for Class I equivalent method samplers.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... sample collection filter) differs significantly from that specified for reference method samplers as... transport is the percentage of a laboratory challenge aerosol which penetrates to the active sample filter of the candidate equivalent method sampler. (2) The active sample filter is the exclusive filter...

  4. 40 CFR 53.59 - Aerosol transport test for Class I equivalent method samplers.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... sample collection filter) differs significantly from that specified for reference method samplers as... transport is the percentage of a laboratory challenge aerosol which penetrates to the active sample filter of the candidate equivalent method sampler. (2) The active sample filter is the exclusive filter...

  5. Electrofracturing test system and method of determining material characteristics of electrofractured material samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bauer, Stephen J.; Glover, Steven F.; Pfeifle, Tom

    A device for electrofracturing a material sample and analyzing the material sample is disclosed. The device simulates an in situ electrofracturing environment so as to obtain electrofractured material characteristics representative of field applications while allowing permeability testing of the fractured sample under in situ conditions.

  6. Sample Size Estimation: The Easy Way

    ERIC Educational Resources Information Center

    Weller, Susan C.

    2015-01-01

    This article presents a simple approach to making quick sample size estimates for basic hypothesis tests. Although there are many sources available for estimating sample sizes, methods are not often integrated across statistical tests, levels of measurement of variables, or effect sizes. A few parameters are required to estimate sample sizes and…

  7. Multiplex Microsphere Immunoassays for the Detection of IgM and IgG to Arboviral Diseases

    PubMed Central

    Basile, Alison J.; Horiuchi, Kalanthe; Panella, Amanda J.; Laven, Janeen; Kosoy, Olga; Lanciotti, Robert S.; Venkateswaran, Neeraja; Biggerstaff, Brad J.

    2013-01-01

    Serodiagnosis of arthropod-borne viruses (arboviruses) at the Division of Vector-Borne Diseases, CDC, employs a combination of individual enzyme-linked immunosorbent assays and microsphere immunoassays (MIAs) to test for IgM and IgG, followed by confirmatory plaque-reduction neutralization tests. Based upon the geographic origin of a sample, it may be tested concurrently for multiple arboviruses, which can be a cumbersome task. The advent of multiplexing represents an opportunity to streamline these types of assays; however, because serologic cross-reactivity of the arboviral antigens often confounds results, it is of interest to employ data analysis methods that address this issue. Here, we constructed 13-virus multiplexed IgM and IgG MIAs that included internal and external controls, based upon the Luminex platform. Results from samples tested using these methods were analyzed using 8 different statistical schemes to identify the best way to classify the data. Geographic batteries were also devised to serve as a more practical diagnostic format, and further samples were tested using the abbreviated multiplexes. Comparative error rates for the classification schemes identified a specific boosting method based on logistic regression “Logitboost” as the classification method of choice. When the data from all samples tested were combined into one set, error rates from the multiplex IgM and IgG MIAs were <5% for all geographic batteries. This work represents both the most comprehensive, validated multiplexing method for arboviruses to date, and also the most systematic attempt to determine the most useful classification method for use with these types of serologic tests. PMID:24086608

  8. Comparison of sampling and test methods for determining asphalt content and moisture correction in asphalt concrete mixtures.

    DOT National Transportation Integrated Search

    1985-03-01

    The purpose of this report is to identify the difference, if any, in AASHTO and OSHD test procedures and results. This report addresses the effect of the size of samples taken in the field and evaluates the methods of determining the moisture content...

  9. 29 CFR 1926.752 - Site layout, site-specific erection plan and construction sequence.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... standard test method of field-cured samples, either 75 percent of the intended minimum compressive design... the basis of an appropriate ASTM standard test method of field-cured samples, either 75 percent of the intended minimum compressive design strength or sufficient strength to support the loads imposed during...

  10. 29 CFR 1926.752 - Site layout, site-specific erection plan and construction sequence.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... standard test method of field-cured samples, either 75 percent of the intended minimum compressive design... the basis of an appropriate ASTM standard test method of field-cured samples, either 75 percent of the intended minimum compressive design strength or sufficient strength to support the loads imposed during...

  11. 29 CFR 1926.752 - Site layout, site-specific erection plan and construction sequence.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... standard test method of field-cured samples, either 75 percent of the intended minimum compressive design... the basis of an appropriate ASTM standard test method of field-cured samples, either 75 percent of the intended minimum compressive design strength or sufficient strength to support the loads imposed during...

  12. 29 CFR 1926.752 - Site layout, site-specific erection plan and construction sequence.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... standard test method of field-cured samples, either 75 percent of the intended minimum compressive design... the basis of an appropriate ASTM standard test method of field-cured samples, either 75 percent of the intended minimum compressive design strength or sufficient strength to support the loads imposed during...

  13. 29 CFR 1926.752 - Site layout, site-specific erection plan and construction sequence.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... standard test method of field-cured samples, either 75 percent of the intended minimum compressive design... the basis of an appropriate ASTM standard test method of field-cured samples, either 75 percent of the intended minimum compressive design strength or sufficient strength to support the loads imposed during...

  14. Sensitivity of different Trypanosoma vivax specific primers for the diagnosis of livestock trypanosomosis using different DNA extraction methods.

    PubMed

    Gonzales, J L; Loza, A; Chacon, E

    2006-03-15

    There are several T. vivax specific primers developed for PCR diagnosis. Most of these primers were validated under different DNA extraction methods and study designs leading to heterogeneity of results. The objective of the present study was to validate PCR as a diagnostic test for T. vivax trypanosomosis by means of determining the test sensitivity of different published specific primers with different sample preparations. Four different DNA extraction methods were used to test the sensitivity of PCR with four different primer sets. DNA was extracted directly from whole blood samples, blood dried on filter papers or blood dried on FTA cards. The results showed that the sensitivity of PCR with each primer set was highly dependant of the sample preparation and DNA extraction method. The highest sensitivities for all the primers tested were determined using DNA extracted from whole blood samples, while the lowest sensitivities were obtained when DNA was extracted from filter paper preparations. To conclude, the obtained results are discussed and a protocol for diagnosis and surveillance for T. vivax trypanosomosis is recommended.

  15. Detection of resistance to linezolid in Staphylococcus aureus infecting orthopedic patients.

    PubMed

    Thool, Vaishali U; Bhoosreddy, Girish L; Wadher, Bharat J

    2012-01-01

    In today's medical scenario, the human race is battling the most intelligent enemy who has unending alternatives to combat with the potent elements they have produced against it. To study the resistance to linezolid among Staphylococcus aureus isolated from pus samples of orthopedic patients. Pus samples were collected from dirty wounds of orthopedic patients undergoing long antimicrobial treatment programs. The sampling period was from July 2010 to June 2011. The samples were collected from different orthopedic hospitals of Nagpur (central India) representing a mixed sample of patients. One hundred pus samples were screened for S. aureus, by growth on mannitol salt agar (MSA), Baird-Parker agar (BPA), deoxyribonuclease test, tube coagulase test, and HiStaph latex agglutination test. Fifty-one S. aureus isolates were obtained which were further subjected to antimicrobial susceptibility testing by Kirby-Bauer disc diffusion method (DDM). Minimal inhibitory concentrations (MICs) were determined by an automated system, the VITEK 2 system. Also, Ezy MIC strip method was carried out in accordance with Clinical and Laboratory Standards Institute (CLSI) guidelines. Twelve linezolid-resistant S. aureus (LRSA) isolates were recovered from 51 S. aureus cultures tested for susceptibility to linezolid using the DDM, VITEK 2 system, and Ezy MIC strip method. The emergence of resistance suggests nosocomial spread and abuse of antibiotic.

  16. Estimation of infection prevalence and sensitivity in a stratified two-stage sampling design employing highly specific diagnostic tests when there is no gold standard.

    PubMed

    Miller, Ezer; Huppert, Amit; Novikov, Ilya; Warburg, Alon; Hailu, Asrat; Abbasi, Ibrahim; Freedman, Laurence S

    2015-11-10

    In this work, we describe a two-stage sampling design to estimate the infection prevalence in a population. In the first stage, an imperfect diagnostic test was performed on a random sample of the population. In the second stage, a different imperfect test was performed in a stratified random sample of the first sample. To estimate infection prevalence, we assumed conditional independence between the diagnostic tests and develop method of moments estimators based on expectations of the proportions of people with positive and negative results on both tests that are functions of the tests' sensitivity, specificity, and the infection prevalence. A closed-form solution of the estimating equations was obtained assuming a specificity of 100% for both tests. We applied our method to estimate the infection prevalence of visceral leishmaniasis according to two quantitative polymerase chain reaction tests performed on blood samples taken from 4756 patients in northern Ethiopia. The sensitivities of the tests were also estimated, as well as the standard errors of all estimates, using a parametric bootstrap. We also examined the impact of departures from our assumptions of 100% specificity and conditional independence on the estimated prevalence. Copyright © 2015 John Wiley & Sons, Ltd.

  17. Molecular method for detection of total coliforms in drinking water samples.

    PubMed

    Maheux, Andrée F; Boudreau, Dominique K; Bisson, Marc-Antoine; Dion-Dupont, Vanessa; Bouchard, Sébastien; Nkuranga, Martine; Bergeron, Michel G; Rodriguez, Manuel J

    2014-07-01

    This work demonstrates the ability of a bacterial concentration and recovery procedure combined with three different PCR assays targeting the lacZ, wecG, and 16S rRNA genes, respectively, to detect the presence of total coliforms in 100-ml samples of potable water (presence/absence test). PCR assays were first compared to the culture-based Colilert and MI agar methods to determine their ability to detect 147 coliform strains representing 76 species of Enterobacteriaceae encountered in fecal and environmental settings. Results showed that 86 (58.5%) and 109 (74.1%) strains yielded a positive signal with Colilert and MI agar methods, respectively, whereas the lacZ, wecG, and 16S rRNA PCR assays detected 133 (90.5%), 111 (75.5%), and 146 (99.3%) of the 147 total coliform strains tested. These assays were then assessed by testing 122 well water samples collected in the Québec City region of Canada. Results showed that 97 (79.5%) of the samples tested by culture-based methods and 95 (77.9%), 82 (67.2%), and 98 (80.3%) of samples tested using PCR-based methods contained total coliforms, respectively. Consequently, despite the high genetic variability of the total coliform group, this study demonstrated that it is possible to use molecular assays to detect total coliforms in potable water: the 16S rRNA molecular assay was shown to be as efficient as recommended culture-based methods. This assay might be used in combination with an Escherichia coli molecular assay to assess drinking water quality. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  18. Molecular Method for Detection of Total Coliforms in Drinking Water Samples

    PubMed Central

    Boudreau, Dominique K.; Bisson, Marc-Antoine; Dion-Dupont, Vanessa; Bouchard, Sébastien; Nkuranga, Martine; Bergeron, Michel G.; Rodriguez, Manuel J.

    2014-01-01

    This work demonstrates the ability of a bacterial concentration and recovery procedure combined with three different PCR assays targeting the lacZ, wecG, and 16S rRNA genes, respectively, to detect the presence of total coliforms in 100-ml samples of potable water (presence/absence test). PCR assays were first compared to the culture-based Colilert and MI agar methods to determine their ability to detect 147 coliform strains representing 76 species of Enterobacteriaceae encountered in fecal and environmental settings. Results showed that 86 (58.5%) and 109 (74.1%) strains yielded a positive signal with Colilert and MI agar methods, respectively, whereas the lacZ, wecG, and 16S rRNA PCR assays detected 133 (90.5%), 111 (75.5%), and 146 (99.3%) of the 147 total coliform strains tested. These assays were then assessed by testing 122 well water samples collected in the Québec City region of Canada. Results showed that 97 (79.5%) of the samples tested by culture-based methods and 95 (77.9%), 82 (67.2%), and 98 (80.3%) of samples tested using PCR-based methods contained total coliforms, respectively. Consequently, despite the high genetic variability of the total coliform group, this study demonstrated that it is possible to use molecular assays to detect total coliforms in potable water: the 16S rRNA molecular assay was shown to be as efficient as recommended culture-based methods. This assay might be used in combination with an Escherichia coli molecular assay to assess drinking water quality. PMID:24771030

  19. Testing non-inferiority of a new treatment in three-arm clinical trials with binary endpoints.

    PubMed

    Tang, Nian-Sheng; Yu, Bin; Tang, Man-Lai

    2014-12-18

    A two-arm non-inferiority trial without a placebo is usually adopted to demonstrate that an experimental treatment is not worse than a reference treatment by a small pre-specified non-inferiority margin due to ethical concerns. Selection of the non-inferiority margin and establishment of assay sensitivity are two major issues in the design, analysis and interpretation for two-arm non-inferiority trials. Alternatively, a three-arm non-inferiority clinical trial including a placebo is usually conducted to assess the assay sensitivity and internal validity of a trial. Recently, some large-sample approaches have been developed to assess the non-inferiority of a new treatment based on the three-arm trial design. However, these methods behave badly with small sample sizes in the three arms. This manuscript aims to develop some reliable small-sample methods to test three-arm non-inferiority. Saddlepoint approximation, exact and approximate unconditional, and bootstrap-resampling methods are developed to calculate p-values of the Wald-type, score and likelihood ratio tests. Simulation studies are conducted to evaluate their performance in terms of type I error rate and power. Our empirical results show that the saddlepoint approximation method generally behaves better than the asymptotic method based on the Wald-type test statistic. For small sample sizes, approximate unconditional and bootstrap-resampling methods based on the score test statistic perform better in the sense that their corresponding type I error rates are generally closer to the prespecified nominal level than those of other test procedures. Both approximate unconditional and bootstrap-resampling test procedures based on the score test statistic are generally recommended for three-arm non-inferiority trials with binary outcomes.

  20. [Research status and prospects of DNA test on difficult specimens].

    PubMed

    Dang, Hua-Wei; Mao, Jiong; Wang, Hui; Huang, Jiang-Ping; Bai, Xiao-Gang

    2012-02-01

    This paper reviews the advances of DNA detection on three types of difficult biological specimens including degraded samples, trace evidences and mixed samples. The source of different samples, processing methods and announcements were analyzed. New methods such as mitochondrial test system, changing the original experimental conditions, low-volume PCR amplification and new technologies such as whole genome amplification techniques, laser capture micro-dissection, and mini-STR technology in recent years are introduced.

  1. 40 CFR Table 6 to Subpart Dddd of... - Model Rule-Emission Limitations That Apply to Incinerators on and After [Date to be specified in...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... per million dry volume 3-run average (1 hour minimum sample time per run) Performance test (Method 10... (Reapproved 2008) c. Oxides of nitrogen 53 parts per million dry volume 3-run average (1 hour minimum sample... average (1 hour minimum sample time per run) Performance test (Method 6 or 6c at 40 CFR part 60, appendix...

  2. 40 CFR Table 6 to Subpart Dddd of... - Model Rule-Emission Limitations That Apply to Incinerators on and After [Date to be specified in...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... per million dry volume 3-run average (1 hour minimum sample time per run) Performance test (Method 10... (Reapproved 2008) c. Oxides of nitrogen 53 parts per million dry volume 3-run average (1 hour minimum sample... average (1 hour minimum sample time per run) Performance test (Method 6 or 6c at 40 CFR part 60, appendix...

  3. Environmental Chemistry Methods (ECM) Index - Q

    EPA Pesticide Factsheets

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with Q as the first character.

  4. Environmental Chemistry Methods (ECM) Index - D

    EPA Pesticide Factsheets

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with D as the first character.

  5. Environmental Chemistry Methods (ECM) Index - N

    EPA Pesticide Factsheets

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with N as the first character.

  6. Environmental Chemistry Methods (ECM) Index - P

    EPA Pesticide Factsheets

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with P as the first character.

  7. Environmental Chemistry Methods (ECM) Index - L

    EPA Pesticide Factsheets

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with L as the first character.

  8. Environmental Chemistry Methods (ECM) Index - T

    EPA Pesticide Factsheets

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with T as the first character.

  9. Environmental Chemistry Methods (ECM) Index - A

    EPA Pesticide Factsheets

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with A as the first character.

  10. Environmental Chemistry Methods (ECM) Index - E

    EPA Pesticide Factsheets

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with E as the first character.

  11. Environmental Chemistry Methods (ECM) Index - O

    EPA Pesticide Factsheets

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with O as the first character.

  12. Environmental Chemistry Methods (ECM) Index - Z

    EPA Pesticide Factsheets

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with Z as the first character.

  13. Environmental Chemistry Methods (ECM) Index - I

    EPA Pesticide Factsheets

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with I as the first character.

  14. Environmental Chemistry Methods (ECM) Index - S

    EPA Pesticide Factsheets

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with S as the first character.

  15. Environmental Chemistry Methods (ECM) Index - K

    EPA Pesticide Factsheets

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with K as the first character.

  16. Environmental Chemistry Methods (ECM) Index - R

    EPA Pesticide Factsheets

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with R as the first character.

  17. Environmental Chemistry Methods (ECM) Index - G

    EPA Pesticide Factsheets

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with G as the first character.

  18. Environmental Chemistry Methods (ECM) Index - F

    EPA Pesticide Factsheets

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with F as the first character.

  19. Environmental Chemistry Methods (ECM) Index - B

    EPA Pesticide Factsheets

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with B as the first character.

  20. Environmental Chemistry Methods (ECM) Index - M

    EPA Pesticide Factsheets

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with M as the first character.

  1. Environmental Chemistry Methods (ECM) Index - C

    EPA Pesticide Factsheets

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with C as the first character.

  2. Environmental Chemistry Methods (ECM) Index - H

    EPA Pesticide Factsheets

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with H as the first character.

  3. Longitudinal study of Escherichia coli O157 shedding and super shedding in dairy heifers.

    PubMed

    Williams, K J; Ward, M P; Dhungyel, O P

    2015-04-01

    A longitudinal study was conducted to assess the methods available for detection of Escherichia coli O157 and to investigate the prevalence and occurrence of long-term shedding and super shedding in a cohort of Australian dairy heifers. Samples were obtained at approximately weekly intervals from heifers at pasture under normal management systems. Selective sampling techniques were used with the aim of identifying heifers with a higher probability of shedding or super shedding. Rectoanal mucosal swabs (RAMS) and fecal samples were obtained from each heifer. Direct culture of feces was used for detection and enumeration. Feces and RAMS were tested by enrichment culture. Selected samples were further tested retrospectively by immunomagnetic separation of enriched samples. Of 784 samples obtained, 154 (19.6%) were detected as positive using culture methods. Adjusting for selective sampling, the prevalence was 71 (15.6%) of 454. In total, 66 samples were detected as positive at >10(2) CFU/g of which 8 were >10(4) CFU/g and classed as super shedding. A significant difference was observed in detection by enriched culture of RAMS and feces. Dairy heifers within this cohort exhibited variable E. coli O157 shedding, consistent with previous estimates of shedding. Super shedding was detected at a low frequency and inconsistently from individual heifers. All detection methods identified some samples as positive that were not detected by any other method, indicating that the testing methods used will influence survey results.

  4. Procedures in the 13C octanoic acid breath test for measurement of gastric emptying: analysis using Bland-Altman methods.

    PubMed

    Clegg, Miriam E; Shafat, Amir

    2010-08-01

    The (13)C octanoic acid breath test (OBT) was first developed as an alternative method of measuring gastric emptying (GE) to scintigraphy. There has been much debate about the test duration and how often measurements need to be taken. This study aims to address these issues. For 78 GE tests using the (13)C OBT, GE lag phase (T(lag)) was calculated while sampling more frequently than the recommended every 15 min. Comparisons between T(lag) were completed using Bland-Altman plots. Similarly, 4 or 6 h test durations were assessed to establish if they yield the same GE half time (T(half)). From one volunteer, samples were taken every 1 min for the first 30 min and then every 15 min until 6 h. GE times were then calculated using different combinations of sampling times. Evidence of a visible T(lag) was also explored from this data. Findings indicated that taking samples every 5 min for the first 30 min instead of every 15 min did not change the GE T(lag) based on Bland-Altman plots. The correlation between these two methods was also high (r(2) = 0.9957). The findings showed that the difference between the two sampling durations 4 and 6 h was large and the correlation between the methods was low (r(2) = 0.8335). Samples taken at a rate of one breath per min indicated lack of a visible T(lag). Sampling for the (13)C OBT should be completed every 15 min for 6 h.

  5. A Third Moment Adjusted Test Statistic for Small Sample Factor Analysis.

    PubMed

    Lin, Johnny; Bentler, Peter M

    2012-01-01

    Goodness of fit testing in factor analysis is based on the assumption that the test statistic is asymptotically chi-square; but this property may not hold in small samples even when the factors and errors are normally distributed in the population. Robust methods such as Browne's asymptotically distribution-free method and Satorra Bentler's mean scaling statistic were developed under the presumption of non-normality in the factors and errors. This paper finds new application to the case where factors and errors are normally distributed in the population but the skewness of the obtained test statistic is still high due to sampling error in the observed indicators. An extension of Satorra Bentler's statistic is proposed that not only scales the mean but also adjusts the degrees of freedom based on the skewness of the obtained test statistic in order to improve its robustness under small samples. A simple simulation study shows that this third moment adjusted statistic asymptotically performs on par with previously proposed methods, and at a very small sample size offers superior Type I error rates under a properly specified model. Data from Mardia, Kent and Bibby's study of students tested for their ability in five content areas that were either open or closed book were used to illustrate the real-world performance of this statistic.

  6. Design and analysis of three-arm trials with negative binomially distributed endpoints.

    PubMed

    Mütze, Tobias; Munk, Axel; Friede, Tim

    2016-02-20

    A three-arm clinical trial design with an experimental treatment, an active control, and a placebo control, commonly referred to as the gold standard design, enables testing of non-inferiority or superiority of the experimental treatment compared with the active control. In this paper, we propose methods for designing and analyzing three-arm trials with negative binomially distributed endpoints. In particular, we develop a Wald-type test with a restricted maximum-likelihood variance estimator for testing non-inferiority or superiority. For this test, sample size and power formulas as well as optimal sample size allocations will be derived. The performance of the proposed test will be assessed in an extensive simulation study with regard to type I error rate, power, sample size, and sample size allocation. For the purpose of comparison, Wald-type statistics with a sample variance estimator and an unrestricted maximum-likelihood estimator are included in the simulation study. We found that the proposed Wald-type test with a restricted variance estimator performed well across the considered scenarios and is therefore recommended for application in clinical trials. The methods proposed are motivated and illustrated by a recent clinical trial in multiple sclerosis. The R package ThreeArmedTrials, which implements the methods discussed in this paper, is available on CRAN. Copyright © 2015 John Wiley & Sons, Ltd.

  7. Comparison of Classical and Charge Storage Methods for Determining Conductivity of Thin Film Insulators

    NASA Technical Reports Server (NTRS)

    Swaminathan, Prasanna; Dennison, J. R.; Sim, Alec; Brunson, Jerilyn; Crapo, Eric; Frederickson, A. R.

    2004-01-01

    Conductivity of insulating materials is a key parameter to determine how accumulated charge will distribute across the spacecraft and how rapidly charge imbalance will dissipate. Classical ASTM and IEC methods to measure thin film insulator conductivity apply a constant voltage to two electrodes around the sample and measure the resulting current for tens of minutes. However, conductivity is more appropriately measured for spacecraft charging applications as the "decay" of charge deposited on the surface of an insulator. Charge decay methods expose one side of the insulator in vacuum to sequences of charged particles, light, and plasma, with a metal electrode attached to the other side of the insulator. Data are obtained by capacitive coupling to measure both the resulting voltage on the open surface and emission of electrons from the exposed surface, as well monitoring currents to the electrode. Instrumentation for both classical and charge storage decay methods has been developed and tested at Jet Propulsion Laboratory (JPL) and at Utah State University (USU). Details of the apparatus, test methods and data analysis are given here. The JPL charge storage decay chamber is a first-generation instrument, designed to make detailed measurements on only three to five samples at a time. Because samples must typically be tested for over a month, a second-generation high sample throughput charge storage decay chamber was developed at USU with the capability of testing up to 32 samples simultaneously. Details are provided about the instrumentation to measure surface charge and current; for charge deposition apparatus and control; the sample holders to properly isolate the mounted samples; the sample carousel to rotate samples into place; the control of the sample environment including sample vacuum, ambient gas, and sample temperature; and the computer control and data acquisition systems. Measurements are compared here for a number of thin film insulators using both methods at both facilities. We have found that conductivity determined from charge storage decay methods is 102 to 104 larger than values obtained from classical methods. Another Spacecraft Charging Conference presentation describes more extensive measurements made with these apparatus. This work is supported through funding from the NASA Space Environments and Effects Program and the USU Space Dynamics Laboratory Enabling Technologies Program.

  8. Machining and characterization of self-reinforced polymers

    NASA Astrophysics Data System (ADS)

    Deepa, A.; Padmanabhan, K.; Kuppan, P.

    2017-11-01

    This Paper focuses on obtaining the mechanical properties and the effect of the different machining techniques on self-reinforced composites sample and to derive the best machining method with remarkable properties. Each sample was tested by the Tensile and Flexural tests, fabricated using hot compaction test and those loads were calculated. These composites are machined using conventional methods because of lack of advanced machinery in most of the industries. The advanced non-conventional methods like Abrasive water jet machining were used. These machining techniques are used to get the better output for the composite materials with good mechanical properties compared to conventional methods. But the use of non-conventional methods causes the changes in the work piece, tool properties and more economical compared to the conventional methods. Finding out the best method ideal for the designing of these Self Reinforced Composites with and without defects and the use of Scanning Electron Microscope (SEM) analysis for the comparing the microstructure of the PP and PE samples concludes our process.

  9. An empirical comparison of isolate-based and sample-based definitions of antimicrobial resistance and their effect on estimates of prevalence.

    PubMed

    Humphry, R W; Evans, J; Webster, C; Tongue, S C; Innocent, G T; Gunn, G J

    2018-02-01

    Antimicrobial resistance is primarily a problem in human medicine but there are unquantified links of transmission in both directions between animal and human populations. Quantitative assessment of the costs and benefits of reduced antimicrobial usage in livestock requires robust quantification of transmission of resistance between animals, the environment and the human population. This in turn requires appropriate measurement of resistance. To tackle this we selected two different methods for determining whether a sample is resistant - one based on screening a sample, the other on testing individual isolates. Our overall objective was to explore the differences arising from choice of measurement. A literature search demonstrated the widespread use of testing of individual isolates. The first aim of this study was to compare, quantitatively, sample level and isolate level screening. Cattle or sheep faecal samples (n=41) submitted for routine parasitology were tested for antimicrobial resistance in two ways: (1) "streak" direct culture onto plates containing the antimicrobial of interest; (2) determination of minimum inhibitory concentration (MIC) of 8-10 isolates per sample compared to published MIC thresholds. Two antibiotics (ampicillin and nalidixic acid) were tested. With ampicillin, direct culture resulted in more than double the number of resistant samples than the MIC method based on eight individual isolates. The second aim of this study was to demonstrate the utility of the observed relationship between these two measures of antimicrobial resistance to re-estimate the prevalence of antimicrobial resistance from a previous study, in which we had used "streak" cultures. Boot-strap methods were used to estimate the proportion of samples that would have tested resistant in the historic study, had we used the isolate-based MIC method instead. Our boot-strap results indicate that our estimates of prevalence of antimicrobial resistance would have been considerably lower in the historic study had the MIC method been used. Finally we conclude that there is no single way of defining a sample as resistant to an antimicrobial agent. The method used greatly affects the estimated prevalence of antimicrobial resistance in a sampled population of animals, thus potentially resulting in misleading results. Comparing methods on the same samples allows us to re-estimate the prevalence from other studies, had other methods for determining resistance been used. The results of this study highlight the importance of establishing what the most appropriate measure of antimicrobial resistance is, for the proposed purpose of the results. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Conclusions on measurement uncertainty in microbiology.

    PubMed

    Forster, Lynne I

    2009-01-01

    Since its first issue in 1999, testing laboratories wishing to comply with all the requirements of ISO/IEC 17025 have been collecting data for estimating uncertainty of measurement for quantitative determinations. In the microbiological field of testing, some debate has arisen as to whether uncertainty needs to be estimated for each method performed in the laboratory for each type of sample matrix tested. Queries also arise concerning the estimation of uncertainty when plate/membrane filter colony counts are below recommended method counting range limits. A selection of water samples (with low to high contamination) was tested in replicate with the associated uncertainty of measurement being estimated from the analytical results obtained. The analyses performed on the water samples included total coliforms, fecal coliforms, fecal streptococci by membrane filtration, and heterotrophic plate counts by the pour plate technique. For those samples where plate/membrane filter colony counts were > or =20, uncertainty estimates at a 95% confidence level were very similar for the methods, being estimated as 0.13, 0.14, 0.14, and 0.12, respectively. For those samples where plate/membrane filter colony counts were <20, estimated uncertainty values for each sample showed close agreement with published confidence limits established using a Poisson distribution approach.

  11. 40 CFR Table 3 of Subpart Bbbbbbb... - Test Methods

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 14 2011-07-01 2011-07-01 false Test Methods 3 Table 3 of Subpart... 3 Table 3 of Subpart BBBBBBB of Part 63—Test Methods For * * * You must use * * * 1. Selecting the sampling locations a and the number of traverse points EPA test method 1 or 1A in appendix A to part 60. 2...

  12. 40 CFR Table 3 of Subpart Bbbbbbb... - Test Methods

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 14 2010-07-01 2010-07-01 false Test Methods 3 Table 3 of Subpart... 3 Table 3 of Subpart BBBBBBB of Part 63—Test Methods For * * * You must use * * * 1. Selecting the sampling locations a and the number of traverse points EPA test method 1 or 1A in appendix A to part 60. 2...

  13. 40 CFR Table 3 of Subpart Bbbbbbb... - Test Methods

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 15 2013-07-01 2013-07-01 false Test Methods 3 Table 3 of Subpart... 3 Table 3 of Subpart BBBBBBB of Part 63—Test Methods For * * * You must use * * * 1. Selecting the sampling locations a and the number of traverse points EPA test method 1 or 1A in appendix A to part 60. 2...

  14. 40 CFR Table 3 of Subpart Bbbbbbb... - Test Methods

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 15 2014-07-01 2014-07-01 false Test Methods 3 Table 3 of Subpart... 3 Table 3 of Subpart BBBBBBB of Part 63—Test Methods For * * * You must use * * * 1. Selecting the sampling locations a and the number of traverse points EPA test method 1 or 1A in appendix A to part 60. 2...

  15. 40 CFR Table 3 of Subpart Bbbbbbb... - Test Methods

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 15 2012-07-01 2012-07-01 false Test Methods 3 Table 3 of Subpart... 3 Table 3 of Subpart BBBBBBB of Part 63—Test Methods For * * * You must use * * * 1. Selecting the sampling locations a and the number of traverse points EPA test method 1 or 1A in appendix A to part 60. 2...

  16. Power calculation for overall hypothesis testing with high-dimensional commensurate outcomes.

    PubMed

    Chi, Yueh-Yun; Gribbin, Matthew J; Johnson, Jacqueline L; Muller, Keith E

    2014-02-28

    The complexity of system biology means that any metabolic, genetic, or proteomic pathway typically includes so many components (e.g., molecules) that statistical methods specialized for overall testing of high-dimensional and commensurate outcomes are required. While many overall tests have been proposed, very few have power and sample size methods. We develop accurate power and sample size methods and software to facilitate study planning for high-dimensional pathway analysis. With an account of any complex correlation structure between high-dimensional outcomes, the new methods allow power calculation even when the sample size is less than the number of variables. We derive the exact (finite-sample) and approximate non-null distributions of the 'univariate' approach to repeated measures test statistic, as well as power-equivalent scenarios useful to generalize our numerical evaluations. Extensive simulations of group comparisons support the accuracy of the approximations even when the ratio of number of variables to sample size is large. We derive a minimum set of constants and parameters sufficient and practical for power calculation. Using the new methods and specifying the minimum set to determine power for a study of metabolic consequences of vitamin B6 deficiency helps illustrate the practical value of the new results. Free software implementing the power and sample size methods applies to a wide range of designs, including one group pre-intervention and post-intervention comparisons, multiple parallel group comparisons with one-way or factorial designs, and the adjustment and evaluation of covariate effects. Copyright © 2013 John Wiley & Sons, Ltd.

  17. A note on power and sample size calculations for the Kruskal-Wallis test for ordered categorical data.

    PubMed

    Fan, Chunpeng; Zhang, Donghui

    2012-01-01

    Although the Kruskal-Wallis test has been widely used to analyze ordered categorical data, power and sample size methods for this test have been investigated to a much lesser extent when the underlying multinomial distributions are unknown. This article generalizes the power and sample size procedures proposed by Fan et al. ( 2011 ) for continuous data to ordered categorical data, when estimates from a pilot study are used in the place of knowledge of the true underlying distribution. Simulations show that the proposed power and sample size formulas perform well. A myelin oligodendrocyte glycoprotein (MOG) induced experimental autoimmunce encephalomyelitis (EAE) mouse study is used to demonstrate the application of the methods.

  18. Probabilistic Requirements (Partial) Verification Methods Best Practices Improvement. Variables Acceptance Sampling Calculators: Empirical Testing. Volume 2

    NASA Technical Reports Server (NTRS)

    Johnson, Kenneth L.; White, K. Preston, Jr.

    2012-01-01

    The NASA Engineering and Safety Center was requested to improve on the Best Practices document produced for the NESC assessment, Verification of Probabilistic Requirements for the Constellation Program, by giving a recommended procedure for using acceptance sampling by variables techniques as an alternative to the potentially resource-intensive acceptance sampling by attributes method given in the document. In this paper, the results of empirical tests intended to assess the accuracy of acceptance sampling plan calculators implemented for six variable distributions are presented.

  19. Gel-based immunotest for simultaneous detection of 2,4,6-trichlorophenol and ochratoxin A in red wine.

    PubMed

    Beloglazova, N V; Goryacheva, I Yu; Rusanova, T Yu; Yurasov, N A; Galve, R; Marco, M-P; De Saeger, S

    2010-07-05

    A new rapid method which allows simultaneous one step detection of two analytes of different nature (2,4,6,-trichlorophenol (TCP) and ochratoxin A (OTA)) in red wine was developed. It was based on a column test with three separate immunolayers: two test layers and one control layer. Each layer consisted of sepharose gel with immobilized anti-OTA (OTA test layer), anti-TCP (TCP test layer) or anti-HRP (control layer) antibodies. Analytes bind to the antibodies in the corresponding test layer while sample flows through the column. Then a mixture of OTA-HRP and TCP-HRP in appropriate dilutions was used, followed by the application of chromogenic substrate. Colour development of the test layer occurred when the corresponding analyte was absent in the sample. HRP-conjugates bound to anti-HRP antibody in the control layer independently of presence or absence of analytes and a blue colour developed in the control layer. Cut-off values for both analytes were 2 microg L(-1). The described method was applied to the simultaneous detection of TCP and OTA in wine samples. To screen the analytes in red wine samples, clean-up columns were used for sample pre-treatment in combination with the test column. Results were confirmed by chromatographic methods. Copyright 2010 Elsevier B.V. All rights reserved.

  20. Investigating Test Equating Methods in Small Samples through Various Factors

    ERIC Educational Resources Information Center

    Asiret, Semih; Sünbül, Seçil Ömür

    2016-01-01

    In this study, equating methods for random group design using small samples through factors such as sample size, difference in difficulty between forms, and guessing parameter was aimed for comparison. Moreover, which method gives better results under which conditions was also investigated. In this study, 5,000 dichotomous simulated data…

  1. Environmental Chemistry Methods (ECM) Index - 0-9

    EPA Pesticide Factsheets

    Laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with a number as the first character.

  2. Detecting Renibacterium salmoninarum in wild brown trout by use of multiple organ samples and diagnostic methods

    USGS Publications Warehouse

    Guomundsdottir, S.; Applegate, Lynn M.; Arnason, I.O.; Kristmundsson, A.; Purcell, Maureen K.; Elliott, Diane G.

    2017-01-01

    Renibacterium salmoninarum, the causative agent of salmonid bacterial kidney disease (BKD), is endemic in many wild trout species in northerly regions. The aim of the present study was to determine the optimal R. salmoninarum sampling/testing strategy for wild brown trout (Salmo trutta L.) populations in Iceland. Fish were netted in a lake and multiple organs—kidney, spleen, gills, oesophagus and mid-gut—were sampled and subjected to five detection tests i.e. culture, polyclonal enzyme-linked immunosorbent assay (pELISA) and three different PCR tests. The results showed that each fish had encountered R. salmoninarum but there were marked differences between results obtained depending on organ and test. The bacterium was not cultured from any kidney sample while all kidney samples were positive by pELISA. At least one organ from 92.9% of the fish tested positive by PCR. The results demonstrated that the choice of tissue and diagnostic method can dramatically influence the outcome of R. salmoninarum surveys.

  3. Estimation of sample size and testing power (part 5).

    PubMed

    Hu, Liang-ping; Bao, Xiao-lei; Guan, Xue; Zhou, Shi-guo

    2012-02-01

    Estimation of sample size and testing power is an important component of research design. This article introduced methods for sample size and testing power estimation of difference test for quantitative and qualitative data with the single-group design, the paired design or the crossover design. To be specific, this article introduced formulas for sample size and testing power estimation of difference test for quantitative and qualitative data with the above three designs, the realization based on the formulas and the POWER procedure of SAS software and elaborated it with examples, which will benefit researchers for implementing the repetition principle.

  4. Evaluating the High Risk Groups for Suicide: A Comparison of Logistic Regression, Support Vector Machine, Decision Tree and Artificial Neural Network

    PubMed Central

    AMINI, Payam; AHMADINIA, Hasan; POOROLAJAL, Jalal; MOQADDASI AMIRI, Mohammad

    2016-01-01

    Background: We aimed to assess the high-risk group for suicide using different classification methods includinglogistic regression (LR), decision tree (DT), artificial neural network (ANN), and support vector machine (SVM). Methods: We used the dataset of a study conducted to predict risk factors of completed suicide in Hamadan Province, the west of Iran, in 2010. To evaluate the high-risk groups for suicide, LR, SVM, DT and ANN were performed. The applied methods were compared using sensitivity, specificity, positive predicted value, negative predicted value, accuracy and the area under curve. Cochran-Q test was implied to check differences in proportion among methods. To assess the association between the observed and predicted values, Ø coefficient, contingency coefficient, and Kendall tau-b were calculated. Results: Gender, age, and job were the most important risk factors for fatal suicide attempts in common for four methods. SVM method showed the highest accuracy 0.68 and 0.67 for training and testing sample, respectively. However, this method resulted in the highest specificity (0.67 for training and 0.68 for testing sample) and the highest sensitivity for training sample (0.85), but the lowest sensitivity for the testing sample (0.53). Cochran-Q test resulted in differences between proportions in different methods (P<0.001). The association of SVM predictions and observed values, Ø coefficient, contingency coefficient, and Kendall tau-b were 0.239, 0.232 and 0.239, respectively. Conclusion: SVM had the best performance to classify fatal suicide attempts comparing to DT, LR and ANN. PMID:27957463

  5. Atlas(®) Listeria monocytogenes LmG2 Detection Assay Using Transcription Mediated Amplification to Detect Listeria monocytogenes in Selected Foods and Stainless Steel Surface.

    PubMed

    Bres, Vanessa; Yang, Hua; Hsu, Ernie; Ren, Yan; Cheng, Ying; Wisniewski, Michele; Hanhan, Maesa; Zaslavsky, Polina; Noll, Nathan; Weaver, Brett; Campbell, Paul; Reshatoff, Michael; Becker, Michael

    2014-01-01

    The Atlas Listeria monocytogenes LmG2 Detection Assay, developed by Roka Bioscience Inc., was compared to a reference culture method for seven food types (hot dogs, cured ham, deli turkey, chicken salad, vanilla ice cream, frozen chocolate cream pie, and frozen cheese pizza) and one surface (stainless steel, grade 316). A 125 g portion of deli turkey was tested using a 1:4 food:media dilution ratio, and a 25 g portion for all other foods was tested using 1:9 food:media dilution ratio. The enrichment time and media for Roka's method was 24 to 28 h for 25 g food samples and environmental surfaces, and 44 to 48 h for 125 g at 35 ± 2°C in PALCAM broth containing 0.02 g/L nalidixic acid. Comparison of the Atlas Listeria monocytogenes LmG2 Detection Assay to the reference method required an unpaired approach. For each matrix, 20 samples inoculated at a fractional level and five samples inoculated at a high level with a different strain of Listeria monocytogenes were tested by each method. The Atlas Listeria monocytogenes LmG2 Detection Assay was compared to the Official Methods of Analysis of AOAC INTERNATIONAL 993.12 method for dairy products, the U.S. Department of Agriculture, Food Safety and Inspection Service, Microbiology Laboratory Guidebook 8.08 method for ready-to-eat meat and environmental samples, and the U.S. Food and Drug Administration Bacteriological Analytical Manual, Chapter 10 method for frozen foods. In the method developer studies, Roka's method, at 24 h (or 44 h for 125 g food samples), had 126 positives out of 200 total inoculated samples, compared to 102 positives for the reference methods at 48 h. In the independent laboratory studies, vanilla ice cream, deli turkey and stainless steel grade 316 were evaluated. Roka's method, at 24 h (or 44 h for 125 g food samples), had 64 positives out of 75 total inoculated samples compared to 54 positives for the reference methods at 48 h. The Atlas Listeria monocytogenes LmG2 Detection Assay detected all 50 L. monocytogenes strains that encompassed 13 serotypes across the various lineages and none of the 30 exclusive organisms, including seven other Listeria species. The product consistency and kit stability studies revealed no statistical differences between the three lots tested or to the term of the shelf life. Finally, the robustness study demonstrated no statistical differences when samples were incubated at 33 ± 2°C or 37 ± 2°C, when enrichment aliquots were 1.3 mL or 1.7 mL, or when the samples were analyzed the same day or five days later. Overall the Atlas Listeria monocytogenes LmG2 Detection Assay is statistically equivalent to or better than the reference methods and is robust to the tested variations.

  6. Establishing Statistical Equivalence of Data from Different Sampling Approaches for Assessment of Bacterial Phenotypic Antimicrobial Resistance

    PubMed Central

    2018-01-01

    ABSTRACT To assess phenotypic bacterial antimicrobial resistance (AMR) in different strata (e.g., host populations, environmental areas, manure, or sewage effluents) for epidemiological purposes, isolates of target bacteria can be obtained from a stratum using various sample types. Also, different sample processing methods can be applied. The MIC of each target antimicrobial drug for each isolate is measured. Statistical equivalence testing of the MIC data for the isolates allows evaluation of whether different sample types or sample processing methods yield equivalent estimates of the bacterial antimicrobial susceptibility in the stratum. We demonstrate this approach on the antimicrobial susceptibility estimates for (i) nontyphoidal Salmonella spp. from ground or trimmed meat versus cecal content samples of cattle in processing plants in 2013-2014 and (ii) nontyphoidal Salmonella spp. from urine, fecal, and blood human samples in 2015 (U.S. National Antimicrobial Resistance Monitoring System data). We found that the sample types for cattle yielded nonequivalent susceptibility estimates for several antimicrobial drug classes and thus may gauge distinct subpopulations of salmonellae. The quinolone and fluoroquinolone susceptibility estimates for nontyphoidal salmonellae from human blood are nonequivalent to those from urine or feces, conjecturally due to the fluoroquinolone (ciprofloxacin) use to treat infections caused by nontyphoidal salmonellae. We also demonstrate statistical equivalence testing for comparing sample processing methods for fecal samples (culturing one versus multiple aliquots per sample) to assess AMR in fecal Escherichia coli. These methods yield equivalent results, except for tetracyclines. Importantly, statistical equivalence testing provides the MIC difference at which the data from two sample types or sample processing methods differ statistically. Data users (e.g., microbiologists and epidemiologists) may then interpret practical relevance of the difference. IMPORTANCE Bacterial antimicrobial resistance (AMR) needs to be assessed in different populations or strata for the purposes of surveillance and determination of the efficacy of interventions to halt AMR dissemination. To assess phenotypic antimicrobial susceptibility, isolates of target bacteria can be obtained from a stratum using different sample types or employing different sample processing methods in the laboratory. The MIC of each target antimicrobial drug for each of the isolates is measured, yielding the MIC distribution across the isolates from each sample type or sample processing method. We describe statistical equivalence testing for the MIC data for evaluating whether two sample types or sample processing methods yield equivalent estimates of the bacterial phenotypic antimicrobial susceptibility in the stratum. This includes estimating the MIC difference at which the data from the two approaches differ statistically. Data users (e.g., microbiologists, epidemiologists, and public health professionals) can then interpret whether that present difference is practically relevant. PMID:29475868

  7. Establishing Statistical Equivalence of Data from Different Sampling Approaches for Assessment of Bacterial Phenotypic Antimicrobial Resistance.

    PubMed

    Shakeri, Heman; Volkova, Victoriya; Wen, Xuesong; Deters, Andrea; Cull, Charley; Drouillard, James; Müller, Christian; Moradijamei, Behnaz; Jaberi-Douraki, Majid

    2018-05-01

    To assess phenotypic bacterial antimicrobial resistance (AMR) in different strata (e.g., host populations, environmental areas, manure, or sewage effluents) for epidemiological purposes, isolates of target bacteria can be obtained from a stratum using various sample types. Also, different sample processing methods can be applied. The MIC of each target antimicrobial drug for each isolate is measured. Statistical equivalence testing of the MIC data for the isolates allows evaluation of whether different sample types or sample processing methods yield equivalent estimates of the bacterial antimicrobial susceptibility in the stratum. We demonstrate this approach on the antimicrobial susceptibility estimates for (i) nontyphoidal Salmonella spp. from ground or trimmed meat versus cecal content samples of cattle in processing plants in 2013-2014 and (ii) nontyphoidal Salmonella spp. from urine, fecal, and blood human samples in 2015 (U.S. National Antimicrobial Resistance Monitoring System data). We found that the sample types for cattle yielded nonequivalent susceptibility estimates for several antimicrobial drug classes and thus may gauge distinct subpopulations of salmonellae. The quinolone and fluoroquinolone susceptibility estimates for nontyphoidal salmonellae from human blood are nonequivalent to those from urine or feces, conjecturally due to the fluoroquinolone (ciprofloxacin) use to treat infections caused by nontyphoidal salmonellae. We also demonstrate statistical equivalence testing for comparing sample processing methods for fecal samples (culturing one versus multiple aliquots per sample) to assess AMR in fecal Escherichia coli These methods yield equivalent results, except for tetracyclines. Importantly, statistical equivalence testing provides the MIC difference at which the data from two sample types or sample processing methods differ statistically. Data users (e.g., microbiologists and epidemiologists) may then interpret practical relevance of the difference. IMPORTANCE Bacterial antimicrobial resistance (AMR) needs to be assessed in different populations or strata for the purposes of surveillance and determination of the efficacy of interventions to halt AMR dissemination. To assess phenotypic antimicrobial susceptibility, isolates of target bacteria can be obtained from a stratum using different sample types or employing different sample processing methods in the laboratory. The MIC of each target antimicrobial drug for each of the isolates is measured, yielding the MIC distribution across the isolates from each sample type or sample processing method. We describe statistical equivalence testing for the MIC data for evaluating whether two sample types or sample processing methods yield equivalent estimates of the bacterial phenotypic antimicrobial susceptibility in the stratum. This includes estimating the MIC difference at which the data from the two approaches differ statistically. Data users (e.g., microbiologists, epidemiologists, and public health professionals) can then interpret whether that present difference is practically relevant. Copyright © 2018 Shakeri et al.

  8. Reevaluation of confirmatory tests for human T-cell leukemia virus Type 1 using a luciferase immunoprecipitation system in blood donors.

    PubMed

    Furuta, Rika A; Ma, Guangyong; Matsuoka, Masao; Otani, Satoshi; Matsukura, Harumichi; Hirayama, Fumiya

    2015-04-01

    Recently, Japanese Red Cross blood centers have changed the confirmatory test method from an indirect immunofluorescence (IF) technique to Western blotting (WB) for antibodies against human T-cell leukemia virus Type 1 (HTLV-1). In this study, these HTLV-1 tests were assessed using another sensitive method, that is, a luciferase immunoprecipitation system (LIPS), to identify a better confirmatory test for HTLV-1 infection. Plasma samples from 54 qualified donors and 114 HTLV-1 screening-positive donors were tested by LIPS for antibodies against HTLV-1 Gag, Tax, Env, and HBZ recombinant proteins. The donors were categorized into six groups, namely, (Group I) qualified donors, screening positive; (Group II) IF positive; (Group III) IF negative; (Group IV) WB positive; (Group V) WB negative; and (Group VI) screening positive in the previous blood donation, but WB-indeterminate during this study period. In Groups II and IV, all plasma samples tested positive by LIPS for antibodies against Gag and Env proteins. In Group V, all samples tested negative by LIPS, whereas some Group III samples reacted with single or double antigens in LIPS. In Group VI, the LIPS test identified a donor with suspected HTLV-1 infection. The first case of a blood donor with plasma that reacted with HBZ was identified by LIPS. Reevaluation of the current HTLV-1 screening method using the LIPS test showed that both confirmatory tests had similar sensitivity and specificity only when WB indeterminate results were eliminated. LIPS is a promising method for detecting and characterizing HTLV-1 antibodies. © 2014 AABB.

  9. Comparison of Sample Size by Bootstrap and by Formulas Based on Normal Distribution Assumption.

    PubMed

    Wang, Zuozhen

    2018-01-01

    Bootstrapping technique is distribution-independent, which provides an indirect way to estimate the sample size for a clinical trial based on a relatively smaller sample. In this paper, sample size estimation to compare two parallel-design arms for continuous data by bootstrap procedure are presented for various test types (inequality, non-inferiority, superiority, and equivalence), respectively. Meanwhile, sample size calculation by mathematical formulas (normal distribution assumption) for the identical data are also carried out. Consequently, power difference between the two calculation methods is acceptably small for all the test types. It shows that the bootstrap procedure is a credible technique for sample size estimation. After that, we compared the powers determined using the two methods based on data that violate the normal distribution assumption. To accommodate the feature of the data, the nonparametric statistical method of Wilcoxon test was applied to compare the two groups in the data during the process of bootstrap power estimation. As a result, the power estimated by normal distribution-based formula is far larger than that by bootstrap for each specific sample size per group. Hence, for this type of data, it is preferable that the bootstrap method be applied for sample size calculation at the beginning, and that the same statistical method as used in the subsequent statistical analysis is employed for each bootstrap sample during the course of bootstrap sample size estimation, provided there is historical true data available that can be well representative of the population to which the proposed trial is planning to extrapolate.

  10. Verification of three-microphone impedance tube method for measurement of transmission loss in aerogels

    NASA Astrophysics Data System (ADS)

    Connick, Robert J.

    Accurate measurement of normal incident transmission loss is essential for the acoustic characterization of building materials. In this research, a method of measuring normal incidence sound transmission loss proposed by Salissou et al. as a complement to standard E2611-09 of the American Society for Testing and Materials [Standard Test Method for Measurement of Normal Incidence Sound Transmission of Acoustical Materials Based on the Transfer Matrix Method (American Society for Testing and Materials, New York, 2009)] is verified. Two sam- ples from the original literature are used to verify the method as well as a Filtros RTM sample. Following the verification, several nano-material Aerogel samples are measured.

  11. Effects of Linking Methods on Detection of DIF.

    ERIC Educational Resources Information Center

    Kim, Seock-Ho; Cohen, Allan S.

    1992-01-01

    Effects of the following methods for linking metrics on detection of differential item functioning (DIF) were compared: (1) test characteristic curve method (TCC); (2) weighted mean and sigma method; and (3) minimum chi-square method. With large samples, results were essentially the same. With small samples, TCC was most accurate. (SLD)

  12. Immunity to human cytomegalovirus measured and compared by complement fixation, indirect fluorescent-antibody, indirect hemagglutination, and enzyme-linked immunosorbent assays.

    PubMed Central

    Brandt, J A; Kettering, J D; Lewis, J E

    1984-01-01

    The complement fixation test is currently the test employed most frequently to determine the presence of antibody to human cytomegalovirus. Several other techniques have been adapted for this purpose. A comparison of cytomegalovirus antibody titers was made between the complement fixation test, a commercially available enzyme-linked immunosorbent assay, an indirect immunofluorescent technique, and a modified indirect hemagglutination test. Forty-three serum samples were tested for antibodies by each of the above procedures. The enzyme-linked immunosorbent, immunofluorescent, and indirect hemagglutination assays were in close agreement on all samples tested; the titers obtained with these methods were all equal to or greater than the complement fixation titer for 38 of the 41 samples (92.6%). Two samples were anticomplementary in the complement fixation test but gave readable results in the other tests. The complement fixation test was the least sensitive of the procedures examined. The commercial enzyme-linked immunosorbent assay system was the most practical method and offered the highest degree of sensitivity in detecting antibodies to cytomegalovirus. PMID:6321544

  13. [Development of a SPA-ELISA method for detecting anti-coronavirus IgG antibodies in serum samples from fulvous fruit bats].

    PubMed

    Zhou, Jie; Liao, Yu-xue; Chen, Zhong; Li, Yu-chun; Gao, Lu-Lu; Chen, Yi-xiong; Cai, Lian-gong; Chen, Qing; Yu, Shou-yi

    2008-05-01

    To develop an simple and sensitive method for detecting anti-coronavirus IgG antibodies in bat sera based on enzyme-linked immunosorbent assay (ELISA). A commercial ELISA kit for detecting SARS-CoV antibody was modified for detecting coronavirus antibodies in bat serum samples. The second antibody in the kit was replaced with horseradish peroxidase-conjugated protein-A (HRP-SPA) based on the characteristics of binding between Staphylococcus aureus protein A (SPA) and mammal IgG Fc fragment. The sera of 55 fulvous fruit bats (Rousettus dasymallus) were tested using the SPA-ELISA. The test results of the positive and negative controls in the kit and the serum samples from convalescent ;patient were consistent with expectation. Coronavirus antibody was detected in 2 out of the 55 bat serum samples. Serum neutralization test confirmed the validity of the SPA-ELISA method. This SPA-ELISA method is applicable for detecting coronavirus antibody in bat sera.

  14. A Comparison of Two Sampling Strategies to Assess Discomycete Diversity in Wet Tropical Forests

    Treesearch

    SHARON A. CANTRELL

    2004-01-01

    Most of the fungal diversity studies that have used a systematic collecting scheme have not included the discomycetes, so optimal sampling methods are not available for this group. In this study, I tested two sampling methods at each sites in the Caribbean National Forest, Puerto Rico and Ebano Verde Reserve, Dominican Republic. For a plot-based sampling method, 10 ×...

  15. Field efficiency and bias of snag inventory methods

    Treesearch

    Robert S. Kenning; Mark J. Ducey; John C. Brissette; Jeffery H. Gove

    2005-01-01

    Snags and cavity trees are important components of forests, but can be difficult to inventory precisely and are not always included in inventories because of limited resources. We tested the application of N-tree distance sampling as a time-saving snag sampling method and compared N-tree distance sampling to fixed-area sampling and modified horizontal line sampling in...

  16. Comparison of flume and towing methods for verifying the calibration of a suspended-sediment sampler

    USGS Publications Warehouse

    Beverage, J.P.; Futrell, J.C.

    1986-01-01

    Suspended-sediment samplers must sample isokinetically (at stream velocity) in order to collect representative water samples of rivers. Each sampler solo by the Federal Interagency Sedimentation Project or by the U.S. Geological Survey Hydrologic Instrumentation Facility has been adjusted to sample isokinetically and tested in a flume to verify the calibration. The test program for a modified U.S. P-61 sampler provided an opportunity to compare flume and towing tank tests. Although the two tests yielded statistically distinct results, the difference between them was quite small. The conclusion is that verifying the calibration of any suspended-sediment sampler by either the flume or towing method should give acceptable results.

  17. Performance Tested Method multiple laboratory validation study of ELISA-based assays for the detection of peanuts in food.

    PubMed

    Park, Douglas L; Coates, Scott; Brewer, Vickery A; Garber, Eric A E; Abouzied, Mohamed; Johnson, Kurt; Ritter, Bruce; McKenzie, Deborah

    2005-01-01

    Performance Tested Method multiple laboratory validations for the detection of peanut protein in 4 different food matrixes were conducted under the auspices of the AOAC Research Institute. In this blind study, 3 commercially available ELISA test kits were validated: Neogen Veratox for Peanut, R-Biopharm RIDASCREEN FAST Peanut, and Tepnel BioKits for Peanut Assay. The food matrixes used were breakfast cereal, cookies, ice cream, and milk chocolate spiked at 0 and 5 ppm peanut. Analyses of the samples were conducted by laboratories representing industry and international and U.S governmental agencies. All 3 commercial test kits successfully identified spiked and peanut-free samples. The validation study required 60 analyses on test samples at the target level 5 microg peanut/g food and 60 analyses at a peanut-free level, which was designed to ensure that the lower 95% confidence limit for the sensitivity and specificity would not be <90%. The probability that a test sample contains an allergen given a prevalence rate of 5% and a positive test result using a single test kit analysis with 95% sensitivity and 95% specificity, which was demonstrated for these test kits, would be 50%. When 2 test kits are run simultaneously on all samples, the probability becomes 95%. It is therefore recommended that all field samples be analyzed with at least 2 of the validated kits.

  18. A Ricin Forensic Profiling Approach Based on a Complex Set of Biomarkers

    DOE PAGES

    Fredriksson, Sten-Ake; Wunschel, David S.; Lindstrom, Susanne Wiklund; ...

    2018-03-28

    A forensic method for the retrospective determination of preparation methods used for illicit ricin toxin production was developed. The method was based on a complex set of biomarkers, including carbohydrates, fatty acids, seed storage proteins, in combination with data on ricin and Ricinus communis agglutinin. The analyses were performed on samples prepared from four castor bean plant (R. communis) cultivars by four different sample preparation methods (PM1 – PM4) ranging from simple disintegration of the castor beans to multi-step preparation methods including different protein precipitation methods. Comprehensive analytical data was collected by use of a range of analytical methods andmore » robust orthogonal partial least squares-discriminant analysis- models (OPLS-DA) were constructed based on the calibration set. By the use of a decision tree and two OPLS-DA models, the sample preparation methods of test set samples were determined. The model statistics of the two models were good and a 100% rate of correct predictions of the test set was achieved.« less

  19. A Ricin Forensic Profiling Approach Based on a Complex Set of Biomarkers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fredriksson, Sten-Ake; Wunschel, David S.; Lindstrom, Susanne Wiklund

    A forensic method for the retrospective determination of preparation methods used for illicit ricin toxin production was developed. The method was based on a complex set of biomarkers, including carbohydrates, fatty acids, seed storage proteins, in combination with data on ricin and Ricinus communis agglutinin. The analyses were performed on samples prepared from four castor bean plant (R. communis) cultivars by four different sample preparation methods (PM1 – PM4) ranging from simple disintegration of the castor beans to multi-step preparation methods including different protein precipitation methods. Comprehensive analytical data was collected by use of a range of analytical methods andmore » robust orthogonal partial least squares-discriminant analysis- models (OPLS-DA) were constructed based on the calibration set. By the use of a decision tree and two OPLS-DA models, the sample preparation methods of test set samples were determined. The model statistics of the two models were good and a 100% rate of correct predictions of the test set was achieved.« less

  20. Progressive sparse representation-based classification using local discrete cosine transform evaluation for image recognition

    NASA Astrophysics Data System (ADS)

    Song, Xiaoning; Feng, Zhen-Hua; Hu, Guosheng; Yang, Xibei; Yang, Jingyu; Qi, Yunsong

    2015-09-01

    This paper proposes a progressive sparse representation-based classification algorithm using local discrete cosine transform (DCT) evaluation to perform face recognition. Specifically, the sum of the contributions of all training samples of each subject is first taken as the contribution of this subject, then the redundant subject with the smallest contribution to the test sample is iteratively eliminated. Second, the progressive method aims at representing the test sample as a linear combination of all the remaining training samples, by which the representation capability of each training sample is exploited to determine the optimal "nearest neighbors" for the test sample. Third, the transformed DCT evaluation is constructed to measure the similarity between the test sample and each local training sample using cosine distance metrics in the DCT domain. The final goal of the proposed method is to determine an optimal weighted sum of nearest neighbors that are obtained under the local correlative degree evaluation, which is approximately equal to the test sample, and we can use this weighted linear combination to perform robust classification. Experimental results conducted on the ORL database of faces (created by the Olivetti Research Laboratory in Cambridge), the FERET face database (managed by the Defense Advanced Research Projects Agency and the National Institute of Standards and Technology), AR face database (created by Aleix Martinez and Robert Benavente in the Computer Vision Center at U.A.B), and USPS handwritten digit database (gathered at the Center of Excellence in Document Analysis and Recognition at SUNY Buffalo) demonstrate the effectiveness of the proposed method.

  1. Lipidomic analysis of biological samples: Comparison of liquid chromatography, supercritical fluid chromatography and direct infusion mass spectrometry methods.

    PubMed

    Lísa, Miroslav; Cífková, Eva; Khalikova, Maria; Ovčačíková, Magdaléna; Holčapek, Michal

    2017-11-24

    Lipidomic analysis of biological samples in a clinical research represents challenging task for analytical methods given by the large number of samples and their extreme complexity. In this work, we compare direct infusion (DI) and chromatography - mass spectrometry (MS) lipidomic approaches represented by three analytical methods in terms of comprehensiveness, sample throughput, and validation results for the lipidomic analysis of biological samples represented by tumor tissue, surrounding normal tissue, plasma, and erythrocytes of kidney cancer patients. Methods are compared in one laboratory using the identical analytical protocol to ensure comparable conditions. Ultrahigh-performance liquid chromatography/MS (UHPLC/MS) method in hydrophilic interaction liquid chromatography mode and DI-MS method are used for this comparison as the most widely used methods for the lipidomic analysis together with ultrahigh-performance supercritical fluid chromatography/MS (UHPSFC/MS) method showing promising results in metabolomics analyses. The nontargeted analysis of pooled samples is performed using all tested methods and 610 lipid species within 23 lipid classes are identified. DI method provides the most comprehensive results due to identification of some polar lipid classes, which are not identified by UHPLC and UHPSFC methods. On the other hand, UHPSFC method provides an excellent sensitivity for less polar lipid classes and the highest sample throughput within 10min method time. The sample consumption of DI method is 125 times higher than for other methods, while only 40μL of organic solvent is used for one sample analysis compared to 3.5mL and 4.9mL in case of UHPLC and UHPSFC methods, respectively. Methods are validated for the quantitative lipidomic analysis of plasma samples with one internal standard for each lipid class. Results show applicability of all tested methods for the lipidomic analysis of biological samples depending on the analysis requirements. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Approximate sample size formulas for the two-sample trimmed mean test with unequal variances.

    PubMed

    Luh, Wei-Ming; Guo, Jiin-Huarng

    2007-05-01

    Yuen's two-sample trimmed mean test statistic is one of the most robust methods to apply when variances are heterogeneous. The present study develops formulas for the sample size required for the test. The formulas are applicable for the cases of unequal variances, non-normality and unequal sample sizes. Given the specified alpha and the power (1-beta), the minimum sample size needed by the proposed formulas under various conditions is less than is given by the conventional formulas. Moreover, given a specified size of sample calculated by the proposed formulas, simulation results show that Yuen's test can achieve statistical power which is generally superior to that of the approximate t test. A numerical example is provided.

  3. A Comparative Serological Study of Toxoplasmosis in Pregnant Women by CLIA and ELISA Methods in Chalus City Iran.

    PubMed

    Elahian Firouz, Zahra; Kaboosi, Hami; Faghih Nasiri, Abdolreza; Tabatabaie, Seyed Saleh; Golhasani-Keshtan, Farideh; Zaboli, Fatemeh

    2014-04-01

    Toxoplasmosis is the most common disease in humans and animals (zoonosis) caused by the protozoan parasite Toxoplasma gondii. The disease is usually appeared as asymptomatic in immunocompromised individuals but its most common symptom is lymphadenopathy. Shortly before or during the first trimester of pregnancy, this disease can be transferred to the fetus and cause serious infection in the fetus. In late pregnancy (third trimester), the complications of this infection is very low or unsigned. Due to the absence of non-specific clinical symptoms or slight infection in pregnant women, prenatal diagnosis is often impossible. Since no research compared these two methods, we decided to compare these methods and determine which method works better for diagnosis of toxoplasmosis. In this study, 50 pregnant women who referred to the Chalus Health Center laboratory were included and the blood samples were tested for presence of IgG and IgM antibodies of Toxoplasma gondii by both ELISA and Chemiluminescence methods. Of the 50 samples tested by the ELISA method, 26 samples (52%) were positive for IgG . No samples were positive for IgM. Of the 50 samples tested by the Chemiluminescence method, 28 samples (56%) were positive for IgG. No samples were positive for IgM. A significant relationship between the age of the youngest child and the infection rate was seen. No significant correlation between age, number of individuals in the household, number of children, location, type of construction, consumption of greens, the way of greens and meat consumption, drug use, history of stillbirth and infection levels was seen.

  4. Efficient statistical tests to compare Youden index: accounting for contingency correlation.

    PubMed

    Chen, Fangyao; Xue, Yuqiang; Tan, Ming T; Chen, Pingyan

    2015-04-30

    Youden index is widely utilized in studies evaluating accuracy of diagnostic tests and performance of predictive, prognostic, or risk models. However, both one and two independent sample tests on Youden index have been derived ignoring the dependence (association) between sensitivity and specificity, resulting in potentially misleading findings. Besides, paired sample test on Youden index is currently unavailable. This article develops efficient statistical inference procedures for one sample, independent, and paired sample tests on Youden index by accounting for contingency correlation, namely associations between sensitivity and specificity and paired samples typically represented in contingency tables. For one and two independent sample tests, the variances are estimated by Delta method, and the statistical inference is based on the central limit theory, which are then verified by bootstrap estimates. For paired samples test, we show that the estimated covariance of the two sensitivities and specificities can be represented as a function of kappa statistic so the test can be readily carried out. We then show the remarkable accuracy of the estimated variance using a constrained optimization approach. Simulation is performed to evaluate the statistical properties of the derived tests. The proposed approaches yield more stable type I errors at the nominal level and substantially higher power (efficiency) than does the original Youden's approach. Therefore, the simple explicit large sample solution performs very well. Because we can readily implement the asymptotic and exact bootstrap computation with common software like R, the method is broadly applicable to the evaluation of diagnostic tests and model performance. Copyright © 2015 John Wiley & Sons, Ltd.

  5. Performance of OncoE6 cervical test with collection methods enabling self-sampling.

    PubMed

    Krings, Amrei; Dückelmann, Anna M; Moser, Lutz; Gollrad, Johannes; Wiegerinck, Maarten; Schweizer, Johannes; Kaufmann, Andreas M

    2018-05-21

    The paradigm shift from cytological screening to Human Papillomavirus (HPV)-based screening for cervical cancer allows the introduction of new technologies in sample collection and diagnostics. The OncoE6™ Cervical Test (OncoE6 Test) is a rapid, easy-to-use lateral flow method detecting HPV16/18 E6 oncoproteins that has proven to detect high-grade cervical lesions with high specificity. If compatible with self-collection samples, this technology might allow for decentralized screening of hard-to-reach populations. For technical validation, cervicovaginal lavages were collected from 20 patients with confirmed HPV16+ or HPV18+ invasive cervical cancer. Cervical smears were collected by polyester-tipped swabs and cytobrushes. All samples were applied to the OncoE6 Test and cytobrush samples additionally genotyped. Lavage, swab, and cytobrush revealed concordant outcome in 18/20 samples. HPV types corresponded with the HPV genotyping by GP5+/6+ PCR analyses. Due to a rare mutation found in the E6 antibody binding site one sample was not detected, another sample had very low cellularity. Overall, vaginal lavages are technically adequate for the OncoE6 Test. Combining self-sampling with oncoprotein rapid testing to detect women with highest risk for severe dysplasia or cancer may allow for secondary cancer prevention in settings where other screening modalities were unsuccessful to date.

  6. Comparisons of NDT Methods to Inspect Cork and Cork filled Epoxy Bands

    NASA Technical Reports Server (NTRS)

    Lingbloom, Mike

    2007-01-01

    Sheet cork and cork filled epoxy provide external insulation for the Reusable Solid Rocket Motor (RSRM) on the Nation's Space Transportation System (STS). Interest in the reliability of the external insulation bonds has increased since the Columbia incident. A non-destructive test (NDT) method that will provide the best inspection for these bonds has been under evaluation. Electronic Shearography has been selected as the primary NDT method for inspection of these bond lines in the RSRM production flow. ATK Launch Systems Group has purchased an electronic shearography system that includes a vacuum chamber that is used for evaluation of test parts and custom vacuum windows for inspection of full-scale motors. Although the electronic shearography technology has been selected as the primary method for inspection of the external bonds, other technologies that exist continue to be investigated. The NASA/Marshall Space Flight Center (MSFC) NDT department has inspected several samples for comparison with electronic shearography with various inspections systems in their laboratory. The systems that were evaluated are X-ray backscatter, terahertz imaging, and microwave imaging. The samples tested have some programmed flaws as well as some flaws that occurred naturally during the sample making process. These samples provide sufficient flaw variation for the evaluation of the different inspection systems. This paper will describe and compare the basic functionality, test method and test results including dissection for each inspection technology.

  7. Evaluation of the lactose Tergitol-7, m-Endo LES, Colilert 18, Readycult Coliforms 100, Water-Check-100, 3M Petrifilm EC and DryCult Coliform test methods for detection of total coliforms and Escherichia coli in water samples.

    PubMed

    Hörman, Ari; Hänninen, Marja-Liisa

    2006-10-01

    In this study we compared the reference membrane filtration (MF) lactose Tergitol-7 (LTTC) method ISO 9308-1:2000 with the MF m-Endo LES method SFS 3016:2001, the defined substrate chromogenic/fluorogenic Colilert 18, Readycult Coliforms and Water Check methods, and ready-made culture media, 3M Petrifilm EC and DryCult Coli methods for the detection of coliforms and Escherichia coli in various water samples. When the results of E. coli detection were compared between test methods, the highest agreement (both tests negative or positive) with the LTTC method was calculated for the m-Endo LES method (83.6%), followed by Colilert 18 (82.7%), Water-Check (81.8%) and Readycult (78.4%), whereas Petrifilm EC (70.6%) and DryCult Coli (68.9%) showed the weakest agreement. The m-Endo LES method was the only method showing no statistical difference in E. coli counts compared with the LTTC method, whereas the Colilert 18 and Readycult methods gave significantly higher counts for E. coli than the LTTC method. In general, those tests based on the analysis of a 1-ml sample (Petrifilm EC and DryCult Coli) showed weak sensitivity (39.5-52.5%) but high specificity (90.9-78.8%).

  8. 40 CFR 53.57 - Test for filter temperature control during sampling and post-sampling periods.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 5 2011-07-01 2011-07-01 false Test for filter temperature control... Class I and Class II Equivalent Methods for PM2.5 or PM10â2.5 § 53.57 Test for filter temperature... candidate sampler's ability to prevent excessive overheating of the PM sample collection filter (or filters...

  9. 40 CFR 53.57 - Test for filter temperature control during sampling and post-sampling periods.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 6 2014-07-01 2014-07-01 false Test for filter temperature control... Class I and Class II Equivalent Methods for PM 2.5 or PM 10-2.5 § 53.57 Test for filter temperature... candidate sampler's ability to prevent excessive overheating of the PM sample collection filter (or filters...

  10. 40 CFR 53.57 - Test for filter temperature control during sampling and post-sampling periods.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Test for filter temperature control... Class I and Class II Equivalent Methods for PM2.5 or PM10â2.5 § 53.57 Test for filter temperature... candidate sampler's ability to prevent excessive overheating of the PM sample collection filter (or filters...

  11. 40 CFR 53.57 - Test for filter temperature control during sampling and post-sampling periods.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 6 2012-07-01 2012-07-01 false Test for filter temperature control... Class I and Class II Equivalent Methods for PM2.5 or PM10â2.5 § 53.57 Test for filter temperature... candidate sampler's ability to prevent excessive overheating of the PM sample collection filter (or filters...

  12. 40 CFR 53.57 - Test for filter temperature control during sampling and post-sampling periods.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 6 2013-07-01 2013-07-01 false Test for filter temperature control... Class I and Class II Equivalent Methods for PM 2.5 or PM 10-2,5 § 53.57 Test for filter temperature... candidate sampler's ability to prevent excessive overheating of the PM sample collection filter (or filters...

  13. Filter for on-line air monitor unaffected by radon progeny and method of using same

    DOEpatents

    Phillips, Terrance D.; Edwards, Howard D.

    1999-01-01

    An apparatus for testing air having contaminants and radon progeny therein. The apparatus includes a sampling box having an inlet for receiving the air and an outlet for discharging the air. The sampling box includes a filter made of a plate of sintered stainless steel. The filter traps the contaminants, yet allows at least a portion of the radon progeny to pass therethrough. A method of testing air having contaminants and radon progeny therein. The method includes providing a testing apparatus that has a sampling box with an inlet for receiving the air and an outlet for discharging the air, and has a sintered stainless steel filter disposed within said sampling box; drawing air from a source into the sampling box using a vacuum pump; passing the air through the filter; monitoring the contaminants trapped by the filter; and providing an alarm when a selected level of contaminants is reached. The filter traps the contaminants, yet allows at least a portion of the radon progeny to pass therethrough.

  14. 40 CFR Appendix A-8 to Part 60 - Test Methods 26 through 30B

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...), and 8.4.4 (Post-Test Leak-Check). 8.1.5Sampling Train Operation. Follow the general procedure given in... 40 Protection of Environment 8 2013-07-01 2013-07-01 false Test Methods 26 through 30B A Appendix... Part 60—Test Methods 26 through 30B Method 26—Determination of Hydrogen Chloride Emissions From...

  15. 40 CFR Appendix A-8 to Part 60 - Test Methods 26 through 30B

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...), and 8.4.4 (Post-Test Leak-Check). 8.1.5Sampling Train Operation. Follow the general procedure given in... 40 Protection of Environment 8 2014-07-01 2014-07-01 false Test Methods 26 through 30B A Appendix... Part 60—Test Methods 26 through 30B Method 26—Determination of Hydrogen Chloride Emissions From...

  16. 40 CFR Appendix A-8 to Part 60 - Test Methods 26 through 30B

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...), and 8.4.4 (Post-Test Leak-Check). 8.1.5Sampling Train Operation. Follow the general procedure given in... 40 Protection of Environment 7 2011-07-01 2011-07-01 false Test Methods 26 through 30B A Appendix... Part 60—Test Methods 26 through 30B Method 26—Determination of Hydrogen Chloride Emissions From...

  17. 40 CFR Appendix A-8 to Part 60 - Test Methods 26 through 30B

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...), and 8.4.4 (Post-Test Leak-Check). 8.1.5Sampling Train Operation. Follow the general procedure given in... 40 Protection of Environment 8 2012-07-01 2012-07-01 false Test Methods 26 through 30B A Appendix... Part 60—Test Methods 26 through 30B Method 26—Determination of Hydrogen Chloride Emissions From...

  18. Combined sample collection and gas extraction for the measurement of helium isotopes and neon in natural waters

    NASA Astrophysics Data System (ADS)

    Roether, Wolfgang; Vogt, Martin; Vogel, Sandra; Sültenfuß, Jürgen

    2013-06-01

    We present a new method to obtain samples for the measurement of helium isotopes and neon in water, to replace the classical sampling procedure using clamped-off Cu tubing containers that we have been using so far. The new method saves the gas extraction step prior to admission to the mass spectrometer, which the classical method requires. Water is drawn into evacuated glass ampoules with subsequent flame sealing. Approximately 50% headspace is left, from which admission into the mass spectrometer occurs without further treatment. Extensive testing has shown that, with due care and with small corrections applied, the samples represent the gas concentrations in the water within ±0.07% (95% confidence level; ±0.05% with special handling). Fast evacuation is achieved by pumping on a small charge of water placed in the ampoule. The new method was successfully tested at sea in comparison with Cu-tubing sampling. We found that the ampoule samples were superior in data precision and that a lower percentage of samples were lost prior to measurement. Further measurements revealed agreement between the two methods in helium, 3He and neon within ±0.1%. The new method facilitates the dealing with large sample sets and minimizes the delay between sampling and measurement. The method is applicable also for gases other than helium and neon.

  19. Water toxicity monitoring using Vibrio fischeri: a method free of interferences from colour and turbidity.

    PubMed

    Faria, Elsa Correia; Treves Brown, Bernard J; Snook, Richard D

    2004-02-01

    In this paper the kinetic method for the determination of toxicity using Vibrio fischeri is described and suggested as a potential method for the continuous screening of wastewater toxicity. The kinetic method was demonstrated to be free from interferences due to colour and turbidity normally observed when testing wastewater samples with this organism. This is of great importance for the application of the method to remote toxicity screening of wastewaters. The effect of colour, investigated using 50 ppm Zn(2+) solutions containing the food-dye tropaeolin O, and the effect of turbidity, investigated using 50 ppm Zn(2+) solutions containing white optically reflective and coloured optically absorbing polystyrene beads, is reported. It was also found that the design of the light detection system of the instrument ensures efficient collection of the light scattered by particles in the sample, which enables a greater range of turbid samples to be tested. In addition the natural light decay was found to be negligible during the duration of a 10 min test and thus one channel would be enough to carry out the tests. This would mean halving the quantity of bacterial reagent used and reducing the cost of the tests.

  20. Domain Regeneration for Cross-Database Micro-Expression Recognition

    NASA Astrophysics Data System (ADS)

    Zong, Yuan; Zheng, Wenming; Huang, Xiaohua; Shi, Jingang; Cui, Zhen; Zhao, Guoying

    2018-05-01

    In this paper, we investigate the cross-database micro-expression recognition problem, where the training and testing samples are from two different micro-expression databases. Under this setting, the training and testing samples would have different feature distributions and hence the performance of most existing micro-expression recognition methods may decrease greatly. To solve this problem, we propose a simple yet effective method called Target Sample Re-Generator (TSRG) in this paper. By using TSRG, we are able to re-generate the samples from target micro-expression database and the re-generated target samples would share same or similar feature distributions with the original source samples. For this reason, we can then use the classifier learned based on the labeled source samples to accurately predict the micro-expression categories of the unlabeled target samples. To evaluate the performance of the proposed TSRG method, extensive cross-database micro-expression recognition experiments designed based on SMIC and CASME II databases are conducted. Compared with recent state-of-the-art cross-database emotion recognition methods, the proposed TSRG achieves more promising results.

  1. Application of a luminescent bacterial biosensor for the detection of tetracyclines in routine analysis of poultry muscle samples.

    PubMed

    Pikkemaat, M G; Rapallini, M L B A; Karp, M T; Elferink, J W A

    2010-08-01

    Tetracyclines are extensively used in veterinary medicine. For the detection of tetracycline residues in animal products, a broad array of methods is available. Luminescent bacterial biosensors represent an attractive inexpensive, simple and fast method for screening large numbers of samples. A previously developed cell-biosensor method was subjected to an evaluation study using over 300 routine poultry samples and the results were compared with a microbial inhibition test. The cell-biosensor assay yielded many more suspect samples, 10.2% versus 2% with the inhibition test, which all could be confirmed by liquid chromatography-tandem mass spectrometry (LC-MS/MS). Only one sample contained a concentration above the maximum residue limit (MRL) of 100 microg kg(-1), while residue levels in most of the suspect samples were very low (<10 microg kg(-1)). The method appeared to be specific and robust. Using an experimental set-up comprising the analysis of a series of three sample dilutions allowed an appropriate cut-off for confirmatory analysis, limiting the number of samples and requiring further analysis to a minimum.

  2. On Bayesian Testing of Additive Conjoint Measurement Axioms Using Synthetic Likelihood

    ERIC Educational Resources Information Center

    Karabatsos, George

    2017-01-01

    This article introduces a Bayesian method for testing the axioms of additive conjoint measurement. The method is based on an importance sampling algorithm that performs likelihood-free, approximate Bayesian inference using a synthetic likelihood to overcome the analytical intractability of this testing problem. This new method improves upon…

  3. 40 CFR 60.285a - Test methods and procedures.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... performance test. (b) The owner or operator must determine compliance with the filterable particulate matter... used to determine the filterable particulate matter concentration. The sampling time and sample volume... repeat performance tests for filterable particulate matter at intervals no longer than 5 years following...

  4. The presence-absence coliform test for monitoring drinking water quality.

    PubMed Central

    Rice, E W; Geldreich, E E; Read, E J

    1989-01-01

    The concern for improved monitoring of the sanitary quality of drinking water has prompted interest in alternative methods for the detection of total coliform bacteria. A simplified qualitative presence-absence test has been proposed as an alternate procedure for detecting coliform bacteria in potable water. In this paper data from four comparative studies were analyzed to compare the recovery of total coliform bacteria from drinking water using the presence-absence test, the multiple fermentation tube procedure, and the membrane filter technique. The four studies were of water samples taken from four different geographic areas of the United States: Hawaii, New England (Vermont and New Hampshire), Oregon, and Pennsylvania. Analysis of the results of these studies were compared, based upon the number of positive samples detected by each method. Combined recoveries showed the presence-absence test detected significantly higher numbers of samples with coliforms than either the fermentation tube or membrane filter methods, P less than 0.01. The fermentation tube procedure detected significantly more positive samples than the membrane filter technique, P less than 0.01. Based upon the analysis of the combined data base, it is clear that the presence-absence test is as sensitive as the current coliform methods for the examination of potable water. The presence-absence test offers a viable alternative to water utility companies that elect to use the frequency-of-occurrence approach for compliance monitoring. PMID:2493663

  5. 40 CFR 63.1385 - Test methods and procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... applicable emission limits: (1) Method 1 (40 CFR part 60, appendix A) for the selection of the sampling port location and number of sampling ports; (2) Method 2 (40 CFR part 60, appendix A) for volumetric flow rate.... Each run shall consist of a minimum run time of 2 hours and a minimum sample volume of 60 dry standard...

  6. 78 FR 14457 - Guidelines Establishing Test Procedures for the Analysis of Pollutants Under the Clean Water Act...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-06

    ... Establishing Test Procedures for the Analysis of Pollutants Under the Clean Water Act; Analysis and Sampling... for use as an alternative oil and grease method. Some comments were specific to the sampling...-side comparison using the specific procedures (e.g. sampling frequency, number of samples, QA/QC, and...

  7. Assessment of the quality of simvastatin capsules from compounding pharmacies.

    PubMed

    Markman, Blanca Elena Ortega; Rosa, Paulo César Pires; Koschtschak, Maria Regina Walter

    2010-12-01

    To validate a method for determining the simvastatin content of compounded capsules, using high performance liquid chromatography. Eighteen samples of simvastatin 40 mg capsules from compounding pharmacies in the cities of São Paulo, Guarulhos, São Bernardo do Campo and Campinas, Southeastern Brazil, prescribed for fictitious patients were assessed. The analyses were based on the Brazilian Pharmacopoeia and on the high performance liquid chromatography method, optimized and validated in accordance with national and international standards for identification and quantification tests on compounded capsules. The mean weight of the capsules ranged from 70 mg to 316 mg; four samples presented weight variation outside of the specification. The simvastatin content in the capsules was within the specification in 11 samples. In six, the content ranged from 4% to 87% of the declared quantity, thereby not complying with the content requirements for the active agent. For one sample, no content or uniformity determinations were performed. In the content uniformity test, 15 samples presented indices of less than 85%, with relative standard deviations greater than 6%. Three pharmacies had met the specification in this test. In the dissolution test, eight samples presented unsatisfactory results in the first stage of the test, while the remainder presented inconclusive results. The method used was shown to be suitable for application to quality control, and it revealed the poor quality of the simvastatin capsules produced by some compounding pharmacies.

  8. Sampling and sample processing in pesticide residue analysis.

    PubMed

    Lehotay, Steven J; Cook, Jo Marie

    2015-05-13

    Proper sampling and sample processing in pesticide residue analysis of food and soil have always been essential to obtain accurate results, but the subject is becoming a greater concern as approximately 100 mg test portions are being analyzed with automated high-throughput analytical methods by agrochemical industry and contract laboratories. As global food trade and the importance of monitoring increase, the food industry and regulatory laboratories are also considering miniaturized high-throughput methods. In conjunction with a summary of the symposium "Residues in Food and Feed - Going from Macro to Micro: The Future of Sample Processing in Residue Analytical Methods" held at the 13th IUPAC International Congress of Pesticide Chemistry, this is an opportune time to review sampling theory and sample processing for pesticide residue analysis. If collected samples and test portions do not adequately represent the actual lot from which they came and provide meaningful results, then all costs, time, and efforts involved in implementing programs using sophisticated analytical instruments and techniques are wasted and can actually yield misleading results. This paper is designed to briefly review the often-neglected but crucial topic of sample collection and processing and put the issue into perspective for the future of pesticide residue analysis. It also emphasizes that analysts should demonstrate the validity of their sample processing approaches for the analytes/matrices of interest and encourages further studies on sampling and sample mass reduction to produce a test portion.

  9. Fading test using the SAAD-POSL method for retrospective accidental dosimetry of building materials

    NASA Astrophysics Data System (ADS)

    Kim, M. J.; Lee, Y. J.; Lee, J. I.; Kim, J. L.; Hong, D. G.

    2015-11-01

    Fading test using the single aliquot additive dose method with pulsed optically stimulated luminescence (SAAD-POSL method) was applied to core-disc samples extracted from heated red brick, tile, roof-tile, and toilet porcelain after X-ray and beta irradiation. From thermoluminescence measurements of each material, the optimal preheat condition of the SAAD-POSL method was first determined as 170 °C for 10 s. Fading characteristics of core-disc samples of heated red brick obtained using the SAAD-POSL method were similar to those of quartz grains (90-250 μm) obtained using the SAR-OSL method, regardless of the differences in the sample and radiation type. Fading evaluations of the core-disc samples of these building materials two weeks after irradiation showed that the equivalent dose (ED) decreased between 5% and 42%. The results indicate that the fading characteristics will be able to contribute to a more accurate estimation of the ED value using the SAAD-POSL method.

  10. Economic and workflow analysis of a blood bank automated system.

    PubMed

    Shin, Kyung-Hwa; Kim, Hyung Hoi; Chang, Chulhun L; Lee, Eun Yup

    2013-07-01

    This study compared the estimated costs and times required for ABO/Rh(D) typing and unexpected antibody screening using an automated system and manual methods. The total cost included direct and labor costs. Labor costs were calculated on the basis of the average operator salaries and unit values (minutes), which was the hands-on time required to test one sample. To estimate unit values, workflows were recorded on video, and the time required for each process was analyzed separately. The unit values of ABO/Rh(D) typing using the manual method were 5.65 and 8.1 min during regular and unsocial working hours, respectively. The unit value was less than 3.5 min when several samples were tested simultaneously. The unit value for unexpected antibody screening was 2.6 min. The unit values using the automated method for ABO/Rh(D) typing, unexpected antibody screening, and both simultaneously were all 1.5 min. The total cost of ABO/Rh(D) typing of only one sample using the automated analyzer was lower than that of testing only one sample using the manual technique but higher than that of testing several samples simultaneously. The total cost of unexpected antibody screening using an automated analyzer was less than that using the manual method. ABO/Rh(D) typing using an automated analyzer incurs a lower unit value and cost than that using the manual technique when only one sample is tested at a time. Unexpected antibody screening using an automated analyzer always incurs a lower unit value and cost than that using the manual technique.

  11. Harmonisation of microbial sampling and testing methods for distillate fuels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hill, G.C.; Hill, E.C.

    1995-05-01

    Increased incidence of microbial infection in distillate fuels has led to a demand for organisations such as the Institute of Petroleum to propose standards for microbiological quality, based on numbers of viable microbial colony forming units. Variations in quality requirements, and in the spoilage significance of contaminating microbes plus a tendency for temporal and spatial changes in the distribution of microbes, makes such standards difficult to implement. The problem is compounded by a diversity in the procedures employed for sampling and testing for microbial contamination and in the interpretation of the data obtained. The following paper reviews these problems andmore » describes the efforts of The Institute of Petroleum Microbiology Fuels Group to address these issues and in particular to bring about harmonisation of sampling and testing methods. The benefits and drawbacks of available test methods, both laboratory based and on-site, are discussed.« less

  12. ECM for Aldicarb in Soil - MRID 49477402

    EPA Pesticide Factsheets

    laboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with A as the first character.

  13. Detection of periodontopathogenic bacteria in pregnant women by traditional anaerobic culture method and by a commercial molecular genetic method.

    PubMed

    Urbán, Edit; Terhes, Gabriella; Radnai, Márta; Gorzó, István; Nagy, Elisabeth

    2010-06-01

    To culture facultative and strict anaerobic bacteria is a well-established method for analyzing subgingival plaque samples. Micro-IDent and micro-IDent Plus (HAIN Lifescience GmbH, Nehren, Germany) tests are two commercially available rapid PCR-based methods for the identification and quantification of putative periodontopathogen bacteria. In this study, we compared these commercial PCR-based hybridization methods with conventional anaerobic culture technique. A total of 36 subgingival plaque samples were collected from periodontal pockets of pregnant women with chronic localized periodontitis. Aliquots of these samples were evaluated with species-specific probes provided by micro-IDent and micro-IDent Plus tests simultaneously, and from the same samples anaerobic and capnophylic bacteria were cultured on selective media. The overall agreement between both methods was excellent for Eubacterium nodatum, Tannerella forsythia and Porphyromonas gingivalis (97-92%), fair for Capnocytophaga sp, Eikenella corrodens, Actinobacillus actinomycetemcomitans, and Prevotella intermedia (91-89%) and poor for Fusobacterium nucleatum, Parvimonas micra (Micromonas micros), and Campylobacter rectus (86-78%). Discrepancies in the results may be explained by inability of culture method to distinguish between closely related taxa (e.i P. intermedia/Prevotella. nigrescens), and problems of keeping periodontopathogen bacteria viable, which is required for successful detection by standard culture method. Nucleic acid-based methods may replace cultivation method as frequently used methods in microbiological diagnosis of progressive periodontitis, thus micro-IDent and micro-IDent Plus tests can be recommended where culture of periodontopathogenic bacteria is not performed in routine microbiology laboratories to analyze subgingival plaque samples. 2010 Elsevier Ltd. All rights reserved.

  14. 40 CFR Table 1 to Subpart Cccc of... - Emission Limitations

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... per dry standard cubic meter 3-run average (1 hour minimum sample time per run) Performance test (Method 29 of appendix A of this part). Carbon monoxide 157 parts per million by dry volume 3-run average (1 hour minimum sample time per run) Performance test (Method 10, 10A, or 10B of appendix A of this...

  15. 40 CFR Table 1 to Subpart Cccc of... - Emission Limitations

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... per dry standard cubic meter 3-run average (1 hour minimum sample time per run) Performance test (Method 29 of appendix A of this part). Carbon monoxide 157 parts per million by dry volume 3-run average (1 hour minimum sample time per run) Performance test (Method 10, 10A, or 10B of appendix A of this...

  16. 40 CFR Table 2 to Subpart Dddd of... - Model Rule-Emission Limitations

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... meter 3-run average (1 hour minimum sample time per run) Performance test (Method 29 of appendix A of this part) Carbon monoxide 157 parts per million by dry volume 3-run average (1 hour minimum sample time per run) Performance test (Method 10, 10A, or 10B, of appendix A of this part) Dioxins/furans...

  17. [Examination of gastric emptying rate by means of 13C-octanoic acid breath test. Methods of the test for adults and results of the investigation of healthy volunteers].

    PubMed

    Bures, J; Kopácová, M; Vorísek, V; Bukac, J; Neumann, D; Rejchrt, S; Pozler, O; Douda, T; Zivný, P; Palicka, V

    2005-01-01

    13C-octanoic acid breath test (13C-OABT) is a simple, safe and non-invasive technique for measuring gastric emptying. However, the method has not been standardized yet. Aim of the study was to work up, introduce and evaluate our own method of the 13C-OABT for adults. Ten healthy volunteers entered the study (5 men, 5 women, mean age 32 years, 50 % Helicobacter pylori positive). Standard test meals (with 100 mg 13C-sodium octanoate) were used three times within 3 weeks. The same solid meal (1,178 kJ) for Tests 1 and 2 contained scrambled egg (+ 3 g oil), white bread (40 g), butter (10 g) and distilled water (200 ml). Semi-solid meal (1,020 kJ) for Test 3 contained milk pudding (200 g) and distilled water (200 ml). Duplicate breath samples were obtained before and every 15 minutes after eating the test meal during 255 minutes. Altogether 1,080 breath samples were analysed twice (isotope ratio mass spectrometry, AP2003 Analytical Precision, UK). To assess the half-life of elimination (t1/2 E), we modelled the process of elimination with the incomplete gamma-function, which has a convenient form for the empiric plotting of breath test data. Mean t1/2E was 136+/-10 minutes (Test 1), 134+/-14 (Test 2) and 123+/-16 minutes (Test 3). Clinical reproducibility of 13C-OABT in particular persons was 98.2% (18 breath samples series), 90.8 % (15 samples) and 87.1% (9 breath samples series). There was a significant correlation between Test 1 and Test 2 results (r=0.887, p<0.0001). Mean difference of duplicate breath sample analysis was 1.460 % (in 540 pairs), mean baseline one-day analysis difference was 0.0982 (99.9274% accuracy). In healthy volunteers, normal range of t1/2E is 110-160 minutes for solids and 91-155 minutes for semisolid test meal. Using our own computed mean time of intermediate metabolism of 13C-octanoic acid (76.5+/-7.5 minutes), gastric emptying half-time is 33.5-83.5 minutes for solids and 14.5-78.5 minutes for semisolid test meal in healthy volunteers. The 13C-OABT is accurate non-invasive method for gastric emptying measurement.

  18. A Third Moment Adjusted Test Statistic for Small Sample Factor Analysis

    PubMed Central

    Lin, Johnny; Bentler, Peter M.

    2012-01-01

    Goodness of fit testing in factor analysis is based on the assumption that the test statistic is asymptotically chi-square; but this property may not hold in small samples even when the factors and errors are normally distributed in the population. Robust methods such as Browne’s asymptotically distribution-free method and Satorra Bentler’s mean scaling statistic were developed under the presumption of non-normality in the factors and errors. This paper finds new application to the case where factors and errors are normally distributed in the population but the skewness of the obtained test statistic is still high due to sampling error in the observed indicators. An extension of Satorra Bentler’s statistic is proposed that not only scales the mean but also adjusts the degrees of freedom based on the skewness of the obtained test statistic in order to improve its robustness under small samples. A simple simulation study shows that this third moment adjusted statistic asymptotically performs on par with previously proposed methods, and at a very small sample size offers superior Type I error rates under a properly specified model. Data from Mardia, Kent and Bibby’s study of students tested for their ability in five content areas that were either open or closed book were used to illustrate the real-world performance of this statistic. PMID:23144511

  19. Testing the non-unity of rate ratio under inverse sampling.

    PubMed

    Tang, Man-Lai; Liao, Yi Jie; Ng, Hong Keung Tony; Chan, Ping Shing

    2007-08-01

    Inverse sampling is considered to be a more appropriate sampling scheme than the usual binomial sampling scheme when subjects arrive sequentially, when the underlying response of interest is acute, and when maximum likelihood estimators of some epidemiologic indices are undefined. In this article, we study various statistics for testing non-unity rate ratios in case-control studies under inverse sampling. These include the Wald, unconditional score, likelihood ratio and conditional score statistics. Three methods (the asymptotic, conditional exact, and Mid-P methods) are adopted for P-value calculation. We evaluate the performance of different combinations of test statistics and P-value calculation methods in terms of their empirical sizes and powers via Monte Carlo simulation. In general, asymptotic score and conditional score tests are preferable for their actual type I error rates are well controlled around the pre-chosen nominal level, and their powers are comparatively the largest. The exact version of Wald test is recommended if one wants to control the actual type I error rate at or below the pre-chosen nominal level. If larger power is expected and fluctuation of sizes around the pre-chosen nominal level are allowed, then the Mid-P version of Wald test is a desirable alternative. We illustrate the methodologies with a real example from a heart disease study. (c) 2007 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim

  20. Evaluation of the Biological Sampling Kit (BiSKit) for Large-Area Surface Sampling

    PubMed Central

    Buttner, Mark P.; Cruz, Patricia; Stetzenbach, Linda D.; Klima-Comba, Amy K.; Stevens, Vanessa L.; Emanuel, Peter A.

    2004-01-01

    Current surface sampling methods for microbial contaminants are designed to sample small areas and utilize culture analysis. The total number of microbes recovered is low because a small area is sampled, making detection of a potential pathogen more difficult. Furthermore, sampling of small areas requires a greater number of samples to be collected, which delays the reporting of results, taxes laboratory resources and staffing, and increases analysis costs. A new biological surface sampling method, the Biological Sampling Kit (BiSKit), designed to sample large areas and to be compatible with testing with a variety of technologies, including PCR and immunoassay, was evaluated and compared to other surface sampling strategies. In experimental room trials, wood laminate and metal surfaces were contaminated by aerosolization of Bacillus atrophaeus spores, a simulant for Bacillus anthracis, into the room, followed by settling of the spores onto the test surfaces. The surfaces were sampled with the BiSKit, a cotton-based swab, and a foam-based swab. Samples were analyzed by culturing, quantitative PCR, and immunological assays. The results showed that the large surface area (1 m2) sampled with the BiSKit resulted in concentrations of B. atrophaeus in samples that were up to 10-fold higher than the concentrations obtained with the other methods tested. A comparison of wet and dry sampling with the BiSKit indicated that dry sampling was more efficient (efficiency, 18.4%) than wet sampling (efficiency, 11.3%). The sensitivities of detection of B. atrophaeus on metal surfaces were 42 ± 5.8 CFU/m2 for wet sampling and 100.5 ± 10.2 CFU/m2 for dry sampling. These results demonstrate that the use of a sampling device capable of sampling larger areas results in higher sensitivity than that obtained with currently available methods and has the advantage of sampling larger areas, thus requiring collection of fewer samples per site. PMID:15574898

  1. Automated measurement of carbohydrate-deficient transferrin using the Bio-Rad %CDT by the HPLC test on a Variant HPLC system: evaluation and comparison with other routine procedures.

    PubMed

    Schellenberg, François; Mennetrey, Louise; Girre, Catherine; Nalpas, Bertrand; Pagès, Jean Christophe

    2008-01-01

    In this study, we evaluated the new %CDT by the HPLC method (Bio-Rad, Germany) on a Varianttrade mark HPLC system (Bio-Rad), checked the correlation with well-known methods and calculated the diagnostic value of the test. Intra-run and day-to-day precision values were calculated for samples with extreme serum transferrin concentrations, high trisialotransferrin and interfering conditions (haemolysed, lactescent and icteric samples). The method was compared with two routine procedures, the %CDT TIA (Bio-Rad, Hercules, CA, USA) and the Capillarystrade mark CDT (Sebia, France). A total of 350 clinical sera samples were used for a case-control study. Precision values were better in high CDT and medium CDT pools than in low CDT pools. The serum transferrin concentration had no effect on CDT measurement, except in samples with serum transferrin <1 g/L. Haemolysis was the only interfering situation. The method showed high correlation (r(2) > 0.95) with the two other methods (%CDT TIA and CZE %CDT). The global predictive value of the test was >0.90 at 1.9% cut-off. These results demonstrate that the %CDT by the HPLC test is suitable for CDT routine measurement; the results from the high-throughput Varianttrade mark system are well correlated with other methods and are of high diagnostic value.

  2. Alternative Confidence Interval Methods Used in the Diagnostic Accuracy Studies

    PubMed Central

    Gülhan, Orekıcı Temel

    2016-01-01

    Background/Aim. It is necessary to decide whether the newly improved methods are better than the standard or reference test or not. To decide whether the new diagnostics test is better than the gold standard test/imperfect standard test, the differences of estimated sensitivity/specificity are calculated with the help of information obtained from samples. However, to generalize this value to the population, it should be given with the confidence intervals. The aim of this study is to evaluate the confidence interval methods developed for the differences between the two dependent sensitivity/specificity values on a clinical application. Materials and Methods. In this study, confidence interval methods like Asymptotic Intervals, Conditional Intervals, Unconditional Interval, Score Intervals, and Nonparametric Methods Based on Relative Effects Intervals are used. Besides, as clinical application, data used in diagnostics study by Dickel et al. (2010) has been taken as a sample. Results. The results belonging to the alternative confidence interval methods for Nickel Sulfate, Potassium Dichromate, and Lanolin Alcohol are given as a table. Conclusion. While preferring the confidence interval methods, the researchers have to consider whether the case to be compared is single ratio or dependent binary ratio differences, the correlation coefficient between the rates in two dependent ratios and the sample sizes. PMID:27478491

  3. Alternative Confidence Interval Methods Used in the Diagnostic Accuracy Studies.

    PubMed

    Erdoğan, Semra; Gülhan, Orekıcı Temel

    2016-01-01

    Background/Aim. It is necessary to decide whether the newly improved methods are better than the standard or reference test or not. To decide whether the new diagnostics test is better than the gold standard test/imperfect standard test, the differences of estimated sensitivity/specificity are calculated with the help of information obtained from samples. However, to generalize this value to the population, it should be given with the confidence intervals. The aim of this study is to evaluate the confidence interval methods developed for the differences between the two dependent sensitivity/specificity values on a clinical application. Materials and Methods. In this study, confidence interval methods like Asymptotic Intervals, Conditional Intervals, Unconditional Interval, Score Intervals, and Nonparametric Methods Based on Relative Effects Intervals are used. Besides, as clinical application, data used in diagnostics study by Dickel et al. (2010) has been taken as a sample. Results. The results belonging to the alternative confidence interval methods for Nickel Sulfate, Potassium Dichromate, and Lanolin Alcohol are given as a table. Conclusion. While preferring the confidence interval methods, the researchers have to consider whether the case to be compared is single ratio or dependent binary ratio differences, the correlation coefficient between the rates in two dependent ratios and the sample sizes.

  4. Surface sampling techniques for 3D object inspection

    NASA Astrophysics Data System (ADS)

    Shih, Chihhsiong S.; Gerhardt, Lester A.

    1995-03-01

    While the uniform sampling method is quite popular for pointwise measurement of manufactured parts, this paper proposes three novel sampling strategies which emphasize 3D non-uniform inspection capability. They are: (a) the adaptive sampling, (b) the local adjustment sampling, and (c) the finite element centroid sampling techniques. The adaptive sampling strategy is based on a recursive surface subdivision process. Two different approaches are described for this adaptive sampling strategy. One uses triangle patches while the other uses rectangle patches. Several real world objects were tested using these two algorithms. Preliminary results show that sample points are distributed more closely around edges, corners, and vertices as desired for many classes of objects. Adaptive sampling using triangle patches is shown to generally perform better than both uniform and adaptive sampling using rectangle patches. The local adjustment sampling strategy uses a set of predefined starting points and then finds the local optimum position of each nodal point. This method approximates the object by moving the points toward object edges and corners. In a hybrid approach, uniform points sets and non-uniform points sets, first preprocessed by the adaptive sampling algorithm on a real world object were then tested using the local adjustment sampling method. The results show that the initial point sets when preprocessed by adaptive sampling using triangle patches, are moved the least amount of distance by the subsequently applied local adjustment method, again showing the superiority of this method. The finite element sampling technique samples the centroids of the surface triangle meshes produced from the finite element method. The performance of this algorithm was compared to that of the adaptive sampling using triangular patches. The adaptive sampling with triangular patches was once again shown to be better on different classes of objects.

  5. Quicklime specification and test methods

    DOT National Transportation Integrated Search

    1987-04-01

    Samples of pebble quicklime were obtained from each of the six major : lime producers' plants in Texas. These samples were used for laboratory : testing which determined chemical composition of the dry lime, physical : properties of slurries prepared...

  6. 40 CFR 63.805 - Performance test methods.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... alternative method for determining the VHAP content of the coating. In the event of any inconsistency between... Collection of Coating and Ink Samples for VOC Content Analysis by Reference Method 24 and Reference Method... (see § 63.801); (iii) Use any alternative protocol and test method provided they meet either the...

  7. Capillary whole blood testing by a new portable monitor. Comparison with standard determination of the international normalized ratio.

    PubMed

    de Miguel, Dunia; Burgaleta, Carmen; Reyes, Eduardo; Pascual, Teresa

    2003-07-01

    We evaluated a new portable monitor (AvoSure PT PRO, Menarini Diagnostics, Firenze, Italy) developed to test the prothrombin time in capillary blood and plasma by comparing it with the standard laboratory determination. We studied 62 patients receiving acenocoumarol therapy. The international normalized ratio (INR) in capillary blood was analyzed by 2 methods: AvoSure PT PRO and Thrombotrack Nycomed Analyzer (Axis-Shield, Dundee, Scotland). Parallel studies were performed in plasma samples by a reference method using the Behring Coagulation Timer (Behring Diagnostics, Marburg, Germany). Plasma samples also were tested with the AvoSure PT PRO. Correlation was good for INR values for capillary blood and plasma samples by AvoSure PT PRO and our reference method (R2 = 0.8596) and for capillary blood samples tested by the AvoSure PT PRO and Thrombotrack Nycomed Analyzer (R2 = 0.8875). The correlation for INR in capillary blood and plasma samples by AvoSure PT PRO was 0.6939 (P < .0004). Capillary blood determinations are rapid and effective for monitoring oral anticoagulation therapy and have a high correlation to plasma determinations. AvoSure PT PRO is accurate for controlling INR in plasma and capillary blood samples, may be used in outpatient clinics, and has advantages over previous portable monitors.

  8. Differentiation and identification of Shigella spp. and enteroinvasive Escherichia coli in environmental waters by a molecular method and biochemical test.

    PubMed

    Hsu, Bing-Mu; Wu, Shu-Fen; Huang, Shih-Wei; Tseng, Yu-Jung; Ji, Dar-Der; Chen, Jung-Sheng; Shih, Feng-Cheng

    2010-02-01

    Both Shigella spp. and enteroinvasive Escherichia coli (EIEC) are important human pathogens that are responsible for the majority of cases of endemic bacillary dysentery. However, they are difficult to identify and differentiate by biochemical tests or molecular methods alone. In this study, we developed a procedure to detect Shigella spp. and EIEC from environmental water samples using membrane filtration followed by nutrient broth enrichment, isolation using selective culture plates, and identification of the invasion plasmid antigen H (ipaH) gene by PCR amplification and DNA sequencing. Finally, we used a biochemical test and a serological assay to differentiate between Shigella and EIEC. Among the 93 water samples from nine reservoirs and one watershed, 76 (81.7%) water samples of culture plates had candidate colonies of Shigella and EIEC and 5 water samples were positive (5.4%) for a Shigella- and EIEC-specific polymerase chain reaction targeting the ipaH gene. Guided by the molecular method, the biochemical test, and the serological assay, 11 ipaH gene-positive isolates from 5 water samples were all identified as EIEC. (c) 2009 Elsevier Ltd. All rights reserved.

  9. Flow Cytometric Human Leukocyte Antigen-B27 Typing with Stored Samples for Batch Testing

    PubMed Central

    Seo, Bo Young

    2013-01-01

    Background Flow cytometry (FC) HLA-B27 typing is still used extensively for the diagnosis of spondyloarthropathies. If patient blood samples are stored for a prolonged duration, this testing can be performed in a batch manner, and in-house cellular controls could easily be procured. In this study, we investigated various methods of storing patient blood samples. Methods We compared four storage methods: three methods of analyzing lymphocytes (whole blood stored at room temperature, frozen mononuclear cells, and frozen white blood cells [WBCs] after lysing red blood cells [RBCs]), and one method using frozen platelets (FPLT). We used three ratios associated with mean fluorescence intensities (MFI) for HLAB27 assignment: the B27 MFI ratio (sample/control) for HLA-B27 fluorescein-5-isothiocyanate (FITC); the B7 MFI ratio for HLA-B7 phycoerythrin (PE); and the ratio of these two ratios, B7/B27 ratio. Results Comparing the B27 MFI ratios of each storage method for the HLA-B27+ samples and the B7/B27 ratios for the HLA-B7+ samples revealed that FPLT was the best of the four methods. FPLT had a sensitivity of 100% and a specificity of 99.3% for HLA-B27 assignment in DNA-typed samples (N=164) when the two criteria, namely, B27 MFI ratio >4.0 and B7/B27 ratio <1.5, were used. Conclusions The FPLT method was found to offer a simple, economical, and accurate method of FC HLA-B27 typing by using stored patient samples. If stored samples are used, this method has the potential to replace the standard FC typing method when used in combination with a complementary DNA-based method. PMID:23667843

  10. Comparative evaluation of gel column agglutination and erythrocyte magnetized technology for red blood cell alloantibody titration.

    PubMed

    Dubey, Anju; Sonker, Atul; Chaudhary, Rajendra K

    2015-01-01

    Antibody titration is traditionally performed using a conventional test tube (CTT) method, which is subjected to interlaboratory variations because of a lack of standardization and reproducibility. The aim of this study is to compare newer methods such as get column technology (GCT) and erythrocyte magnetized technology (EMT) for antibody titration in terms of accuracy and precision. Patient serum samples that contained immunoglobin G (IgG) red blood cell (RBC) alloantibodies of a single specificity for Rh or K anitgens were identified during routine transfusion service testing and stored. Titration and scoring were performed separately by and stored. Titration and scoring were performed separately by different laboratory personnel on CTT, GCT, and EMT. Testing was performed a total of three times on each sample. Results were analyzed for accuracy and precision. A total of 50 samples were tested. Only 20 percent of samples tested with GCT shoed titers identical to CTT, whereas 48 percent of samples tested with EMT showed titers identical to CTT. Overall, the mean of th titer difference from CTT was higher using GCT (+0.31) compared with that using EMT (+0.13). Precision shown by CTT was 30 percent, EMT was 76 percent, and GCT was 92 percent on repeat testing. GCT showed higher titer values in comparison with CTT but was found to be the most precise. EMT titers were comparable to CTT, and its precision was intermediate. Further studies to validate this method are required.

  11. Serological tests for detecting Rift Valley fever viral antibodies in sheep from the Nile Delta.

    PubMed Central

    Scott, R M; Feinsod, F M; Allam, I H; Ksiazek, T G; Peters, C J; Botros, B A; Darwish, M A

    1986-01-01

    To determine the accuracy of serological methods in detecting Rift Valley fever (RVF) viral antibodies, we examined serum samples obtained from 418 sheep in the Nile Delta by using five tests. The plaque reduction neutralization test (PRNT) was considered the standard serological method against which the four other tests were compared. Twenty-four serum samples had RVF viral antibodies detected by PRNT. Hemagglutination inhibition and enzyme-linked immunosorbent assay antibodies to RVF virus were also present in the same 24 serum samples. Indirect immunofluorescence was less sensitive in comparison with PRNT, and complement fixation was the least sensitive. These results extend observations made with laboratory animals to a large field-collected group of Egyptian sheep. PMID:3533977

  12. Device for high spatial resolution chemical analysis of a sample and method of high spatial resolution chemical analysis

    DOEpatents

    Van Berkel, Gary J.

    2015-10-06

    A system and method for analyzing a chemical composition of a specimen are described. The system can include at least one pin; a sampling device configured to contact a liquid with a specimen on the at least one pin to form a testing solution; and a stepper mechanism configured to move the at least one pin and the sampling device relative to one another. The system can also include an analytical instrument for determining a chemical composition of the specimen from the testing solution. In particular, the systems and methods described herein enable chemical analysis of specimens, such as tissue, to be evaluated in a manner that the spatial-resolution is limited by the size of the pins used to obtain tissue samples, not the size of the sampling device used to solubilize the samples coupled to the pins.

  13. Evaluation of Two Surface Sampling Methods for Detection of Erwinia herbicola on a Variety of Materials by Culture and Quantitative PCR▿

    PubMed Central

    Buttner, Mark P.; Cruz, Patricia; Stetzenbach, Linda D.; Cronin, Tracy

    2007-01-01

    This research was designed to evaluate surface sampling protocols for use with culture and quantitative PCR (QPCR) amplification assay for detection of the gram-negative bacterial biothreat simulant Erwinia herbicola on a variety of surface materials. Surfaces selected for evaluation were wood laminate, glass and computer monitor screens, metal file cabinets, plastic arena seats, nylon seat cushions, finished concrete flooring, and vinyl tile flooring. Laboratory and test chamber studies were performed to evaluate two sampling methods, a sponge and a macrofoam swab, for detection of E. herbicola on surface materials. In laboratory trials, seven materials were inoculated with a known concentration of E. herbicola cells and samples were collected from the surfaces of the materials to determine sampling efficiencies. Culture analysis was ineffective for assessing E. herbicola collection efficiency because very few culturable cells were obtained from surface samples. QPCR demonstrated that E. herbicola DNA was present in high concentrations on all of the surface samples, and sampling efficiencies ranged from 0.7 to 52.2%, depending on the sampling method and the surface material. The swab was generally more efficient than the sponge for collection of E. herbicola from surfaces. Test chamber trials were also performed in which E. herbicola was aerosolized into the chamber and allowed to settle onto test materials. Surface sampling results supported those obtained in laboratory trials. The results of this study demonstrate the capabilities of QPCR to enhance the detection and enumeration of biocontaminants on surface materials and provide information on the comparability of sampling methods. PMID:17416685

  14. Evaluation of two surface sampling methods for detection of Erwinia herbicola on a variety of materials by culture and quantitative PCR.

    PubMed

    Buttner, Mark P; Cruz, Patricia; Stetzenbach, Linda D; Cronin, Tracy

    2007-06-01

    This research was designed to evaluate surface sampling protocols for use with culture and quantitative PCR (QPCR) amplification assay for detection of the gram-negative bacterial biothreat simulant Erwinia herbicola on a variety of surface materials. Surfaces selected for evaluation were wood laminate, glass and computer monitor screens, metal file cabinets, plastic arena seats, nylon seat cushions, finished concrete flooring, and vinyl tile flooring. Laboratory and test chamber studies were performed to evaluate two sampling methods, a sponge and a macrofoam swab, for detection of E. herbicola on surface materials. In laboratory trials, seven materials were inoculated with a known concentration of E. herbicola cells and samples were collected from the surfaces of the materials to determine sampling efficiencies. Culture analysis was ineffective for assessing E. herbicola collection efficiency because very few culturable cells were obtained from surface samples. QPCR demonstrated that E. herbicola DNA was present in high concentrations on all of the surface samples, and sampling efficiencies ranged from 0.7 to 52.2%, depending on the sampling method and the surface material. The swab was generally more efficient than the sponge for collection of E. herbicola from surfaces. Test chamber trials were also performed in which E. herbicola was aerosolized into the chamber and allowed to settle onto test materials. Surface sampling results supported those obtained in laboratory trials. The results of this study demonstrate the capabilities of QPCR to enhance the detection and enumeration of biocontaminants on surface materials and provide information on the comparability of sampling methods.

  15. EBUS-TBNA Provides Highest RNA Yield for Multiple Biomarker Testing from Routinely Obtained Small Biopsies in Non-Small Cell Lung Cancer Patients - A Comparative Study of Three Different Minimal Invasive Sampling Methods

    PubMed Central

    Schmid-Bindert, Gerald; Wang, Yongsheng; Jiang, Hongbin; Sun, Hui; Henzler, Thomas; Wang, Hao; Pilz, Lothar R.; Ren, Shengxiang; Zhou, Caicun

    2013-01-01

    Background Multiple biomarker testing is necessary to facilitate individualized treatment of lung cancer patients. More than 80% of lung cancers are diagnosed based on very small tumor samples. Often there is not enough tissue for molecular analysis. We compared three minimal invasive sampling methods with respect to RNA quantity for molecular testing. Methods 106 small biopsies were prospectively collected by three different methods forceps biopsy, endobronchial ultrasound (EBUS) guided transbronchial needle aspiration (TBNA), and CT-guided core biopsy. Samples were split into two halves. One part was formalin fixed and paraffin embedded for standard pathological evaluation. The other part was put in RNAlater for immediate RNA/DNA extraction. If the pathologist confirmed the diagnosis of non-small cell lung cancer(NSCLC), the following molecular markers were tested: EGFR mutation, ERCC1, RRM1 and BRCA1. Results Overall, RNA-extraction was possible in 101 out of 106 patients (95.3%). We found 49% adenocarcinomas, 38% squamouscarcinomas, and 14% non-otherwise-specified(NOS). The highest RNA yield came from endobronchial ultrasound guided needle aspiration, which was significantly higher than bronchoscopy (37.74±41.09 vs. 13.74±15.53 ng respectively, P = 0.005) and numerically higher than CT-core biopsy (37.74±41.09 vs. 28.72±44.27 ng respectively, P = 0.244). EGFR mutation testing was feasible in 100% of evaluable patients and its incidence was 40.8%, 7.9% and 14.3% in adenocarcinomas, squamouscarcinomas and NSCLC NOS subgroup respectively. There was no difference in the feasibility of molecular testing between the three sampling methods with feasibility rates for ERCC1, RRM1 and BRCA1 of 91%, 87% and 81% respectively. Conclusion All three methods can provide sufficient tumor material for multiple biomarkers testing from routinely obtained small biopsies in lung cancer patients. In our study EBUS guided needle aspiration provided the highest amount of tumor RNA compared to bronchoscopy or CT guided core biopsy. Thus EBUS should be considered as an acceptable option for tissue acquisition for molecular testing. PMID:24205040

  16. Sampling High-Altitude and Stratified Mating Flights of Red Imported Fire Ant

    USDA-ARS?s Scientific Manuscript database

    With the exception of an airplane equipped with nets, no method has been developed that successfully samples red imported fire ant, Solenopsis invicta Buren, sexuals in mating/dispersal flights throughout their potential altitudinal trajectories. We developed and tested a method for sampling queens ...

  17. ECM for Aldicarb & Degradates in Water - MRID 49515901

    EPA Pesticide Factsheets

    aboratories use testing methods to identify pesticides in water and soil. Environmental chemistry methods test soil and water samples to determine the fate of pesticides in the environment. Find methods for chemicals with A as the first character.

  18. Fluid permeability measurement system and method

    DOEpatents

    Hallman, Jr., Russell Louis; Renner, Michael John [Oak Ridge, TN

    2008-02-05

    A system for measuring the permeance of a material. The permeability of the material may also be derived. The system provides a liquid or high concentration fluid bath on one side of a material test sample, and a gas flow across the opposing side of the material test sample. The mass flow rate of permeated fluid as a fraction of the combined mass flow rate of gas and permeated fluid is used to calculate the permeance of the material. The material test sample may be a sheet, a tube, or a solid shape. Operational test conditions may be varied, including concentration of the fluid, temperature of the fluid, strain profile of the material test sample, and differential pressure across the material test sample.

  19. Material permeance measurement system and method

    DOEpatents

    Hallman, Jr., Russell Louis; Renner, Michael John [Oak Ridge, TN

    2012-05-08

    A system for measuring the permeance of a material. The permeability of the material may also be derived. The system provides a liquid or high concentration fluid bath on one side of a material test sample, and a gas flow across the opposing side of the material test sample. The mass flow rate of permeated fluid as a fraction of the combined mass flow rate of gas and permeated fluid is used to calculate the permeance of the material. The material test sample may be a sheet, a tube, or a solid shape. Operational test conditions may be varied, including concentration of the fluid, temperature of the fluid, strain profile of the material test sample, and differential pressure across the material test sample.

  20. Anodonta imbecillis QA Test 1, Clinch River - Environmental Restoration Program (CR-ERP)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simbeck, D.J.

    1997-06-01

    Toxicity testing of split whole sediment samples using juvenile freshwater mussels (Anodonta imbecillis) was conducted by TVA and CR-ERP personnel as part of the CR-ERP biomonitoring study of Clinch River sediments to provide a quality assurance mechanism for test organism quality and overall performance of the test. In addition, testing included procedures comparing daily renewal versus non-renewal of test sediments. Testing of sediment samples collected July 15 from Poplar Creek Miles 6.0 and 5.1 was conducted from July 21-30, 1993. Results from this test showed no toxicity (survival effects) to fresh-water mussels during a 9-day exposure to the sediments. Sidemore » by side testing of sediments with daily sediment renewal and no sediment renewal showed no differences between methods. This may be due to the absence of toxicity in both samples and may not reflect true differences between the two methods for toxic sediment.« less

  1. Screening for tinea unguium by Dermatophyte Test Strip.

    PubMed

    Tsunemi, Y; Takehara, K; Miura, Y; Nakagami, G; Sanada, H; Kawashima, M

    2014-02-01

    The direct microscopy, fungal culture and histopathology that are necessary for the definitive diagnosis of tinea unguium are disadvantageous in that detection sensitivity is affected by the level of skill of the person who performs the testing, and the procedures take a long time. The Dermatophyte Test Strip, which was developed recently, can simply and easily detect filamentous fungi in samples in a short time, and there are expectations for its use as a method for tinea unguium screening. With this in mind, we examined the detection capacity of the Dermatophyte Test Strip for tinea unguium. The presence or absence of fungal elements was judged by direct microscopy and Dermatophyte Test Strip in 165 nail samples obtained from residents in nursing homes for the elderly. Moreover, the minimum sample amount required for positive determination was estimated using 32 samples that showed positive results by Dermatophyte Test Strip. The Dermatophyte Test Strip showed 98% sensitivity, 78% specificity, 84·8% positive predictive value, 97% negative predictive value and a positive and negative concordance rate of 89·1%. The minimum sample amount required for positive determination was 0·002-0·722 mg. The Dermatophyte Test Strip showed very high sensitivity and negative predictive value, and was considered a potentially useful method for tinea unguium screening. Positive determination was considered to be possible with a sample amount of about 1 mg. © 2013 British Association of Dermatologists.

  2. Quantitative PCR detection of Batrachochytrium dendrobatidis DNA from sediments and water

    USGS Publications Warehouse

    Kirshtein, Julie D.; Anderson, Chauncey W.; Wood, J.S.; Longcore, Joyce E.; Voytek, Mary A.

    2007-01-01

    The fungal pathogen Batrachochytrium dendrobatidis (Bd) causes chytridiomycosis, a disease implicated in amphibian declines on 5 continents. Polymerase chain reaction (PCR) primer sets exist with which amphibians can be tested for this disease, and advances in sampling techniques allow non-invasive testing of animals. We developed filtering and PCR based quantitative methods by modifying existing PCR assays to detect Bd DNA in water and sediments, without the need for testing amphibians; we tested the methods at 4 field sites. The SYBR based assay using Boyle primers (SYBR/Boyle assay) and the Taqman based assay using Wood primers performed similarly with samples generated in the laboratory (Bd spiked filters), but the SYBR/Boyle assay detected Bd DNA in more field samples. We detected Bd DNA in water from 3 of 4 sites tested, including one pond historically negative for chytridiomycosis. Zoospore equivalents in sampled water ranged from 19 to 454 l-1 (nominal detection limit is 10 DNA copies, or about 0.06 zoospore). We did not detect DNA of Bd from sediments collected at any sites. Our filtering and amplification methods provide a new tool to investigate critical aspects of Bd in the environment. ?? Inter-Research 2007.

  3. GEE-based SNP set association test for continuous and discrete traits in family-based association studies.

    PubMed

    Wang, Xuefeng; Lee, Seunggeun; Zhu, Xiaofeng; Redline, Susan; Lin, Xihong

    2013-12-01

    Family-based genetic association studies of related individuals provide opportunities to detect genetic variants that complement studies of unrelated individuals. Most statistical methods for family association studies for common variants are single marker based, which test one SNP a time. In this paper, we consider testing the effect of an SNP set, e.g., SNPs in a gene, in family studies, for both continuous and discrete traits. Specifically, we propose a generalized estimating equations (GEEs) based kernel association test, a variance component based testing method, to test for the association between a phenotype and multiple variants in an SNP set jointly using family samples. The proposed approach allows for both continuous and discrete traits, where the correlation among family members is taken into account through the use of an empirical covariance estimator. We derive the theoretical distribution of the proposed statistic under the null and develop analytical methods to calculate the P-values. We also propose an efficient resampling method for correcting for small sample size bias in family studies. The proposed method allows for easily incorporating covariates and SNP-SNP interactions. Simulation studies show that the proposed method properly controls for type I error rates under both random and ascertained sampling schemes in family studies. We demonstrate through simulation studies that our approach has superior performance for association mapping compared to the single marker based minimum P-value GEE test for an SNP-set effect over a range of scenarios. We illustrate the application of the proposed method using data from the Cleveland Family GWAS Study. © 2013 WILEY PERIODICALS, INC.

  4. Evaluation of the Thermo Scientific SureTect Listeria species assay. AOAC Performance Tested Method 071304.

    PubMed

    Cloke, Jonathan; Evans, Katharine; Crabtree, David; Hughes, Annette; Simpson, Helen; Holopainen, Jani; Wickstrand, Nina; Kauppinen, Mikko; Leon-Velarde, Carlos; Larson, Nathan; Dave, Keron

    2014-01-01

    The Thermo Scientific SureTect Listeria species Assay is a new real-time PCR assay for the detection of all species of Listeria in food and environmental samples. This validation study was conducted using the AOAC Research Institute (RI) Performance Tested Methods program to validate the SureTect Listeria species Assay in comparison to the reference method detailed in International Organization for Standardization 11290-1:1996 including amendment 1:2004 in a variety of foods plus plastic and stainless steel. The food matrixes validated were smoked salmon, processed cheese, fresh bagged spinach, cantaloupe, cooked prawns, cooked sliced turkey meat, cooked sliced ham, salami, pork frankfurters, and raw ground beef. All matrixes were tested by Thermo Fisher Scientific, Microbiology Division, Basingstoke, UK. In addition, three matrixes (pork frankfurters, fresh bagged spinach, and stainless steel surface samples) were analyzed independently as part of the AOAC-RI-controlled independent laboratory study by the University ofGuelph, Canada. Using probability of detection statistical analysis, a significant difference in favour of the SureTect assay was demonstrated between the SureTect and reference method for high level spiked samples of pork frankfurters, smoked salmon, cooked prawns, stainless steel, and low-spiked samples of salami. For all other matrixes, no significant difference was seen between the two methods during the study. Inclusivity testing was conducted with 68 different isolates of Listeria species, all of which were detected by the SureTect Listeria species Assay. None of the 33 exclusivity isolates were detected by the SureTect Listeria species Assay. Ruggedness testing was conducted to evaluate the performance of the assay with specific method deviations outside of the recommended parameters open to variation, which demonstrated that the assay gave reliable performance. Accelerated stability testing was additionally conducted, validating the assay shelf life.

  5. An improved SRC method based on virtual samples for face recognition

    NASA Astrophysics Data System (ADS)

    Fu, Lijun; Chen, Deyun; Lin, Kezheng; Li, Ao

    2018-07-01

    The sparse representation classifier (SRC) performs classification by evaluating which class leads to the minimum representation error. However, in real world, the number of available training samples is limited due to noise interference, training samples cannot accurately represent the test sample linearly. Therefore, in this paper, we first produce virtual samples by exploiting original training samples at the aim of increasing the number of training samples. Then, we take the intra-class difference as data representation of partial noise, and utilize the intra-class differences and training samples simultaneously to represent the test sample in a linear way according to the theory of SRC algorithm. Using weighted score level fusion, the respective representation scores of the virtual samples and the original training samples are fused together to obtain the final classification results. The experimental results on multiple face databases show that our proposed method has a very satisfactory classification performance.

  6. The "3 in 1" Study: Pooling Self-Taken Pharyngeal, Urethral, and Rectal Samples into a Single Sample for Analysis for Detection of Neisseria gonorrhoeae and Chlamydia trachomatis in Men Who Have Sex with Men.

    PubMed

    Sultan, B; White, J A; Fish, R; Carrick, G; Brima, N; Copas, A; Robinson, A; Gilson, R; Mercey, D; Benn, P

    2016-03-01

    Triple-site testing (using pharyngeal, rectal, and urethral/first-void urine samples) for Neisseria gonorrhoeae and Chlamydia trachomatis using nucleic acid amplification tests detects greater numbers of infections among men who have sex with men (MSM). However, triple-site testing represents a cost pressure for services. MSM over 18 years of age were eligible if they requested testing for sexually transmitted infections (STIs), reported recent sexual contact with either C. trachomatis or N. gonorrhoeae, or had symptoms of an STI. Each patient underwent standard-of-care (SOC) triple-site testing, and swabs were taken to form a pooled sample (PS) (pharyngeal, rectal, and urine specimens). The PS was created using two methods during different periods at one clinic, but we analyzed the data in combination because the sensitivity of the two methods did not differ significantly for C. trachomatis (P = 0.774) or N. gonorrhoeae (P = 0.163). The sensitivity of PS testing (92%) was slightly lower than that of SOC testing (96%) for detecting C. trachomatis (P = 0.167). For N. gonorrhoeae, the sensitivity of PS testing (90%) was significantly lower than that of SOC testing (99%) (P < 0.001). When pharynx-only infections were excluded, the sensitivity of PS testing to detect N. gonorrhoeae infections increased to 94%. Our findings show that pooling of self-taken samples could be an effective and cost-saving method, with high negative predictive values. (Interim results of this study were presented at the BASHH 2013 summer meeting.). Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  7. ctDNA Determination of EGFR Mutation Status in European and Japanese Patients with Advanced NSCLC: The ASSESS Study.

    PubMed

    Reck, Martin; Hagiwara, Koichi; Han, Baohui; Tjulandin, Sergei; Grohé, Christian; Yokoi, Takashi; Morabito, Alessandro; Novello, Silvia; Arriola, Edurne; Molinier, Olivier; McCormack, Rose; Ratcliffe, Marianne; Normanno, Nicola

    2016-10-01

    To offer patients with EGFR mutation-positive advanced NSCLC appropriate EGFR tyrosine kinase inhibitor treatment, mutation testing of tumor samples is required. However, tissue/cytologic samples are not always available or evaluable. The large, noninterventional diagnostic ASSESS study (NCT01785888) evaluated the utility of circulating free tumor-derived DNA (ctDNA) from plasma for EGFR mutation testing. ASSESS was conducted in 56 centers (in Europe and Japan). Eligible patients (with newly diagnosed locally advanced/metastatic treatment-naive advanced NSCLC) provided diagnostic tissue/cytologic and plasma samples. DNA extracted from tissue/cytologic samples was subjected to EGFR mutation testing using local practices; designated laboratories performed DNA extraction/mutation testing of blood samples. The primary end point was level of concordance of EGFR mutation status between matched tissue/cytologic and plasma samples. Of 1311 patients enrolled, 1288 were eligible. Concordance of mutation status in 1162 matched samples was 89% (sensitivity 46%, specificity 97%, positive predictive value 78%, and negative predictive value 90%). A group of 25 patients with apparent false-positive plasma results was overrepresented for cytologic samples, use of less sensitive tissue testing methodologies, and smoking habits associated with high EGFR mutation frequency, indicative of false-negative tumor results. In cases in which plasma and tumor samples were tested with identical highly sensitive methods, positive predictive value/sensitivity were generally improved. These real-world data suggest that ctDNA is a feasible sample for EGFR mutation analysis. It is important to conduct mutation testing of both tumor and plasma samples in specialized laboratories, using robust/sensitive methods to ensure that patients receive appropriate treatments that target the molecular features of their disease. Copyright © 2016 International Association for the Study of Lung Cancer. Published by Elsevier Inc. All rights reserved.

  8. Testing an Impedance Non-destructive Method to Evaluate Steel-Fiber Concrete Samples

    NASA Astrophysics Data System (ADS)

    Komarkova, Tereza; Fiala, Pavel; Steinbauer, Miloslav; Roubal, Zdenek

    2018-02-01

    Steel-fiber reinforced concrete is a composite material characterized by outstanding tensile properties and resistance to the development of cracks. The concrete, however, exhibits such characteristics only on the condition that the steel fibers in the final, hardened composite have been distributed evenly. The current methods to evaluate the distribution and concentration of a fiber composite are either destructive or exhibit a limited capability of evaluating the concentration and orientation of the fibers. In this context, the paper discusses tests related to the evaluation of the density and orientation of fibers in a composite material. Compared to the approaches used to date, the proposed technique is based on the evaluation of the electrical impedance Z in the band close to the resonance of the sensor-sample configuration. Using analytically expressed equations, we can evaluate the monitored part of the composite and its density at various depths of the tested sample. The method employs test blocks of composites, utilizing the resonance of the measuring device and the measured sample set; the desired state occurs within the interval of between f=3 kHz and 400 kHz.

  9. Effects of disease severity distribution on the performance of quantitative diagnostic methods and proposal of a novel 'V-plot' methodology to display accuracy values.

    PubMed

    Petraco, Ricardo; Dehbi, Hakim-Moulay; Howard, James P; Shun-Shin, Matthew J; Sen, Sayan; Nijjer, Sukhjinder S; Mayet, Jamil; Davies, Justin E; Francis, Darrel P

    2018-01-01

    Diagnostic accuracy is widely accepted by researchers and clinicians as an optimal expression of a test's performance. The aim of this study was to evaluate the effects of disease severity distribution on values of diagnostic accuracy as well as propose a sample-independent methodology to calculate and display accuracy of diagnostic tests. We evaluated the diagnostic relationship between two hypothetical methods to measure serum cholesterol (Chol rapid and Chol gold ) by generating samples with statistical software and (1) keeping the numerical relationship between methods unchanged and (2) changing the distribution of cholesterol values. Metrics of categorical agreement were calculated (accuracy, sensitivity and specificity). Finally, a novel methodology to display and calculate accuracy values was presented (the V-plot of accuracies). No single value of diagnostic accuracy can be used to describe the relationship between tests, as accuracy is a metric heavily affected by the underlying sample distribution. Our novel proposed methodology, the V-plot of accuracies, can be used as a sample-independent measure of a test performance against a reference gold standard.

  10. Estimating Total-Test Scores from Partial Scores in a Matrix Sampling Design.

    ERIC Educational Resources Information Center

    Sachar, Jane; Suppes, Patrick

    1980-01-01

    The present study compared six methods, two of which utilize the content structure of items, to estimate total-test scores using 450 students and 60 items of the 110-item Stanford Mental Arithmetic Test. Three methods yielded fairly good estimates of the total-test score. (Author/RL)

  11. Development of Methodologic Tools for Planning and Managing Library Services: II. Measuring a Library's Capability for Providing Documents *

    PubMed Central

    Orr, Richard H.; Pings, Vern M.; Pizer, Irwin H.; Olson, Edwin E.; Spencer, Carol C.

    1968-01-01

    A method of measuring a library's capability for providing the documents its users need has been developed. The library is tested with a representative sample of such documents to determine how long would be required for users to obtain these documents. Test results are expressed in terms of a Capability Index, which has a maximal value of 100 only if all the sample documents are found “on shelf.” Specific tests employing samples of 300 documents have been developed that are appropriate for academic and for “reservoir” biomedical libraries. Realistic field trials have demonstrated that these two tests are practical to administer and that test results are adequately reproducible. When strict comparability is not important, a library can test itself. In assessing a reservoir library, test results are supplemented by data on its typical processing time for interlibrary loan requests. Currently these tests are being used in a national survey. The general method is applicable to other types of libraries, provided appropriate test samples are established. If their limitations are clearly understood, these “Document Delivery Tests” can be valuable tools for planning and managing library services. PMID:5665969

  12. Method of quantitating dsDNA

    DOEpatents

    Stark, Peter C.; Kuske, Cheryl R.; Mullen, Kenneth I.

    2002-01-01

    A method for quantitating dsDNA in an aqueous sample solution containing an unknown amount of dsDNA. A first aqueous test solution containing a known amount of a fluorescent dye-dsDNA complex and at least one fluorescence-attenutating contaminant is prepared. The fluorescence intensity of the test solution is measured. The first test solution is diluted by a known amount to provide a second test solution having a known concentration of dsDNA. The fluorescence intensity of the second test solution is measured. Additional diluted test solutions are similarly prepared until a sufficiently dilute test solution having a known amount of dsDNA is prepared that has a fluorescence intensity that is not attenuated upon further dilution. The value of the maximum absorbance of this solution between 200-900 nanometers (nm), referred to herein as the threshold absorbance, is measured. A sample solution having an unknown amount of dsDNA and an absorbance identical to that of the sufficiently dilute test solution at the same chosen wavelength is prepared. Dye is then added to the sample solution to form the fluorescent dye-dsDNA-complex, after which the fluorescence intensity of the sample solution is measured and the quantity of dsDNA in the sample solution is determined. Once the threshold absorbance of a sample solution obtained from a particular environment has been determined, any similarly prepared sample solution taken from a similar environment and having the same value for the threshold absorbance can be quantified for dsDNA by adding a large excess of dye to the sample solution and measuring its fluorescence intensity.

  13. Evaluation of modifications of the traditional patch test in assessing the chemical irritation potential of feminine hygiene products.

    PubMed

    Farage, Miranda A; Meyer, Sandy; Walter, Dave

    2004-05-01

    The first main objective of the work presented in this paper was to investigate ways of optimizing the current arm patch test protocol by (1) increasing the sensitivity of the test in order to evaluate more effectively the products that are inherently non-irritating, and/or (2) reducing the costs of these types of studies by shortening the protocol. The second main objective was to use the results of these studies and the results of the parallel studies conducted using the behind-the-knee method to better understand the contribution of mechanical irritation to the skin effects produced by these types of products. In addition, we were interested in continuing the evaluation of sensory effects and their relationship to objective measures of irritation. Test materials were prepared from three, currently marketed feminine protection pads. Wet and dry samples were applied to the upper arm using the standard 24-h patch test. Applications were repeated daily for 4 consecutive days. The test sites were scored for irritation prior to the first patch application, and 30-60 min after removal of each patch. Some test sites were treated by tape stripping the skin prior to the initial patch application. In addition, in one experiment, panelists were asked to keep a daily diary describing any sensory skin effects they noticed at each test site. All protocol variations ([intact skin/dry samples], [compromised skin/dry samples], [intact skin/wet samples], and [compromised skin/wet samples]) gave similar results for the products tested. When compared to the behind-the-knee test method, the standard upper arm patch test gave consistently lower levels of irritation when the test sites were scored shortly after patch removal, even though the sample application was longer (24 vs. 6 h) in the standard patch test. The higher level of irritation in the behind-the-knee method was likely due to mechanical irritation. The sensory skin effects did not appear to be related to a particular test product or a particular protocol variation. However, the mean irritation scores at those sites where a sensory effect was reported were higher than the mean irritation scores at those sites were no sensory effects were reported. All four protocol variations of the standard upper arm patch test can be used to assess the inherent chemical irritant properties of feminine protection products. For these products, which are inherently non-irritating, tape stripping and/or applying wet samples does not increase the sensitivity of the patch test method. Differences in irritation potential were apparent after one to three 24-h applications. Therefore, the standard patch test protocol can be shortened to three applications without compromising our ability to detect differences in the chemical irritation produced by the test materials. The patch test can be used to evaluate effectively the inherent chemical irritation potential of these types of products. However, this method is not suitable for testing the mechanical irritation due to friction that occurs during product use. There is no relationship between specific test conditions, i.e., compromised skin and/or testing wet samples and reports of perceived sensory reactions. However, there seems to be a clear relationship between sensory reactions and objective irritation scores.

  14. Item Selection for the Development of Parallel Forms from an IRT-Based Seed Test Using a Sampling and Classification Approach

    ERIC Educational Resources Information Center

    Chen, Pei-Hua; Chang, Hua-Hua; Wu, Haiyan

    2012-01-01

    Two sampling-and-classification-based procedures were developed for automated test assembly: the Cell Only and the Cell and Cube methods. A simulation study based on a 540-item bank was conducted to compare the performance of the procedures with the performance of a mixed-integer programming (MIP) method for assembling multiple parallel test…

  15. Segments from red blood cell units should not be used for quality testing.

    PubMed

    Kurach, Jayme D R; Hansen, Adele L; Turner, Tracey R; Jenkins, Craig; Acker, Jason P

    2014-02-01

    Nondestructive testing of blood components could permit in-process quality control and reduce discards. Tubing segments, generated during red blood cell (RBC) component production, were tested to determine their suitability as a sample source for quality testing. Leukoreduced RBC components were produced from whole blood (WB) by two different methods: WB filtration and buffy coat (BC). Components and their corresponding segments were tested on Days 5 and 42 of hypothermic storage (HS) for spun hematocrit (Hct), hemoglobin (Hb) content, percentage hemolysis, hematologic indices, and adenosine triphosphate concentration to determine whether segment quality represents unit quality. Segment samples overestimated hemolysis on Days 5 and 42 of HS in both BC- and WB filtration-produced RBCs (p < 0.001 for all). Hct and Hb levels in the segments were also significantly different from the units at both time points for both production methods (p < 0.001 for all). Indeed, for all variables tested different results were obtained from segment and unit samples, and these differences were not consistent across production methods. The quality of samples from tubing segments is not representative of the quality of the corresponding RBC unit. Segments are not suitable surrogates with which to assess RBC quality. © 2013 American Association of Blood Banks.

  16. Use of immuno assays during the development of a Hemophilus influenzae type b vaccine for technology transfer to emerging vaccine manufacturers.

    PubMed

    Hamidi, Ahd; Kreeftenberg, Hans

    2014-01-01

    Quality control of Hemophilus Influenzae type b (Hib) conjugate vaccines is mainly dependent on physicochemical methods. Overcoming sample matrix interference when using physicochemical tests is very challenging, these tests are therefore only used to test purified samples of polysaccharide, protein, bulk conjugate, and final product. For successful development of a Hib conjugate vaccine, several ELISA (enzyme-linked immunosorbent assay) methods were needed as an additional tool to enable testing of in process (IP) samples. In this paper, three of the ELISA's that have been very valuable during the process development, implementation and scaling up are highlighted. The PRP-ELISA, was a very efficient tool in testing in process (IP) samples generated during the development of the cultivation and purification process of the Hib-polysaccharide. The antigenicity ELISA, was used to confirm the covalent linkage of PRP and TTd in the conjugate. The anti-PRP IgG ELISA was developed as part of the immunogenicity test, used to demonstrate the ability of the Hib conjugate vaccine to elicit a T-cell dependent immune response in mice. ELISA methods are relatively cheap and easy to implement and therefore very useful during the development of polysaccharide conjugate vaccines.

  17. 40 CFR Table E-1 to Subpart E of... - Summary of Test Requirements for Reference and Class I Equivalent Methods for PM 2.5 and PM 10-2.5

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... accuracy 3. Filter temp. control accuracy, sampling and non-sampling 1. 2 °C2. 2 °C 3. Not more than 5 °C... Reference and Class I Equivalent Methods for PM 2.5 and PM 10-2.5 E Table E-1 to Subpart E of Part 53... MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance...

  18. 40 CFR Table E-1 to Subpart E of... - Summary of Test Requirements for Reference and Class I Equivalent Methods for PM2.5 and PM10-2.5

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... accuracy 3. Filter temp. control accuracy, sampling and non-sampling 1. 2 °C2. 2 °C 3. Not more than 5 °C... Reference and Class I Equivalent Methods for PM2.5 and PM10-2.5 E Table E-1 to Subpart E of Part 53... MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance...

  19. 40 CFR Table E-1 to Subpart E of... - Summary of Test Requirements for Reference and Class I Equivalent Methods for PM2.5 and PM10-2.5

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... accuracy 3. Filter temp. control accuracy, sampling and non-sampling 1. 2 °C2. 2 °C 3. Not more than 5 °C... Reference and Class I Equivalent Methods for PM2.5 and PM10-2.5 E Table E-1 to Subpart E of Part 53... MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance...

  20. 40 CFR Table E-1 to Subpart E of... - Summary of Test Requirements for Reference and Class I Equivalent Methods for PM 2.5 and PM 10-2.5

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... accuracy 3. Filter temp. control accuracy, sampling and non-sampling 1. 2 °C2. 2 °C 3. Not more than 5 °C... Reference and Class I Equivalent Methods for PM 2.5 and PM 10-2.5 E Table E-1 to Subpart E of Part 53... MONITORING REFERENCE AND EQUIVALENT METHODS Procedures for Testing Physical (Design) and Performance...

  1. Small sample mediation testing: misplaced confidence in bootstrapped confidence intervals.

    PubMed

    Koopman, Joel; Howe, Michael; Hollenbeck, John R; Sin, Hock-Peng

    2015-01-01

    Bootstrapping is an analytical tool commonly used in psychology to test the statistical significance of the indirect effect in mediation models. Bootstrapping proponents have particularly advocated for its use for samples of 20-80 cases. This advocacy has been heeded, especially in the Journal of Applied Psychology, as researchers are increasingly utilizing bootstrapping to test mediation with samples in this range. We discuss reasons to be concerned with this escalation, and in a simulation study focused specifically on this range of sample sizes, we demonstrate not only that bootstrapping has insufficient statistical power to provide a rigorous hypothesis test in most conditions but also that bootstrapping has a tendency to exhibit an inflated Type I error rate. We then extend our simulations to investigate an alternative empirical resampling method as well as a Bayesian approach and demonstrate that they exhibit comparable statistical power to bootstrapping in small samples without the associated inflated Type I error. Implications for researchers testing mediation hypotheses in small samples are presented. For researchers wishing to use these methods in their own research, we have provided R syntax in the online supplemental materials. (c) 2015 APA, all rights reserved.

  2. Equivalency testing of TTC Tergitol 7 agar (ISO 9308-1:2000) with five culture media for the detection of E. coli in water samples in Greece.

    PubMed

    Mavridou, A; Smeti, E; Mandilara, G; Mandilara, G; Boufa, P; Vagiona-Arvanitidou, M; Vantarakis, A; Vassilandonopoulou, G; Pappa, O; Roussia, V; Tzouanopoulos, A; Livadara, M; Aisopou, I; Maraka, V; Nikolaou, E; Mandilara, G

    2010-01-01

    In this study ten laboratories in Greece compared the performance of reference method TTC Tergitol 7 Agar (with the additional test of beta-glucuronidase production) with five alternative methods, to detect E. coli in water, in line with European Water Directive recommendations. The samples were prepared by spiking drinking water with sewage effluent following a standard protocol. Chlorinated and non-chlorinated samples were used. The statistical analysis was based on the mean relative difference of confirmed counts and was performed in line with ISO 17994. The results showed that in total, three of the alternative methods (Chromocult Coliform agar, Membrane Lauryl Sulfate agar and Trypton Bilex-glucuronidase medium) were not different from TTC Tergitol 7 agar (TTC Tergitol 7 agar vs Chromocult Coliform agar, 294 samples, mean RD% 5.55; vs MLSA, 302 samples, mean RD% 1; vs TBX, 297 samples, mean RD% -2.78). The other two alternative methods (Membrane Faecal coliform medium and Colilert 18/ Quantitray) gave significantly higher counts than TTC Tergitol 7 agar (TTC Tergitol 7 agar vs MFc, 303 samples, mean RD% 8.81; vs Colilert-18/Quantitray, 76 samples, mean RD% 18.91). In other words, the alternative methods generated performance that was as reliable as, or even better than, the reference method. This study will help laboratories in Greece overcome culture and counting problems deriving from the EU reference method for E. coli counts in water samples.

  3. Improved method for fluorescence cytometric immunohematology testing.

    PubMed

    Roback, John D; Barclay, Sheilagh; Hillyer, Christopher D

    2004-02-01

    A method for accurate immunohematology testing by fluorescence cytometry (FC) was previously described. Nevertheless, the use of vacuum filtration to wash RBCs and a standard-flow cytometer for data acquisition hindered efforts to incorporate this method into an automated platform. A modified procedure was developed that used low-speed centrifugation of 96-well filter plates for RBC staining. Small-footprint benchtop capillary cytometers (PCA and PCA-96, Guava Technologies, Inc.) were used for data acquisition. Authentic clinical samples from hospitalized patients were tested for ABO group and the presence of D antigen (n = 749) as well as for the presence of RBC alloantibodies (n = 428). Challenging samples with mixed-field reactions and weak antibodies were included. Results were compared to those obtained by column agglutination technology (CAT), and discrepancies were resolved by standard tube methods. Detailed investigations of FC sensitivity and reproducibility were also performed. The modified FC method with the PCA determined the correct ABO group and D type for 98.7 percent of 520 samples, compared to 98.8 percent for CAT (p > 0.05). No-type-determined (NTD) rates were 1.2 percent for both methods. In testing for unexpected alloantibodies, FC determined the correct result for 98.6 percent of 215 samples, compared to 96.3 percent for CAT (p > 0.05). When samples were automatically acquired in the 96-well plate format with the PCA-96, 98.7 percent of 229 samples had correct ABO group and D type determined by FC, compared to 97.4 percent for CAT (p > 0.05). NTD rates were 0.9 and 2.6 percent, respectively. Antibody screens were accurate for 99.1 percent of 213 samples with the PCA-96, compared to 99.5 percent for CAT (p > 0.05). Further investigations demonstrated that FC with the PCA-96 was better than CAT at detecting weak anti-A (p < 0.0001) and alloantibodies. An improved method for FC immunohematology testing has been described. This assay was comparable in accuracy to standard CAT techniques, but had better sensitivity for detecting weak antibodies and was superior in detecting mixed-field reactions (p < 0.005). The FC method demonstrated excellent reproducibility. The compatibility of this assay with the PCA-96 capillary cytometer with plate-handling capabilities should simplify development of a completely automated platform.

  4. Development and validation of an HPLC–MS/MS method to determine clopidogrel in human plasma

    PubMed Central

    Liu, Gangyi; Dong, Chunxia; Shen, Weiwei; Lu, Xiaopei; Zhang, Mengqi; Gui, Yuzhou; Zhou, Qinyi; Yu, Chen

    2015-01-01

    A quantitative method for clopidogrel using online-SPE tandem LC–MS/MS was developed and fully validated according to the well-established FDA guidelines. The method achieves adequate sensitivity for pharmacokinetic studies, with lower limit of quantifications (LLOQs) as low as 10 pg/mL. Chromatographic separations were performed on reversed phase columns Kromasil Eternity-2.5-C18-UHPLC for both methods. Positive electrospray ionization in multiple reaction monitoring (MRM) mode was employed for signal detection and a deuterated analogue (clopidogrel-d4) was used as internal standard (IS). Adjustments in sample preparation, including introduction of an online-SPE system proved to be the most effective method to solve the analyte back-conversion in clinical samples. Pooled clinical samples (two levels) were prepared and successfully used as real-sample quality control (QC) in the validation of back-conversion testing under different conditions. The result showed that the real samples were stable in room temperature for 24 h. Linearity, precision, extraction recovery, matrix effect on spiked QC samples and stability tests on both spiked QCs and real sample QCs stored in different conditions met the acceptance criteria. This online-SPE method was successfully applied to a bioequivalence study of 75 mg single dose clopidogrel tablets in 48 healthy male subjects. PMID:26904399

  5. Stability of hepatitis C virus RNA and anti-HCV antibody in air-dried and freeze-dried human plasma samples.

    PubMed

    Poe, Amanda; Duong, Ngocvien Thi; Bedi, Kanwar; Kodani, Maja

    2018-03-01

    Diagnosis of hepatitis C virus (HCV) infection is based on testing for antibodies to HCV (anti-HCV), hepatitis C core antigen (HCV cAg) and HCV RNA. To ensure quality control (QC) and quality assurance (QA), proficiency panels are provided by reference laboratories and various international organizations, requiring costly dry ice shipments to maintain specimen integrity. Alternative methods of specimen preservation and transport can save on shipping and handling and help in improving diagnostics by facilitating QA/QC of various laboratories especially in resource limited countries. Plasma samples positive for anti-HCV and HCV RNA were either dried using dried tube specimens (DTS) method or lyophilization for varying durations of time and temperature. Preservation of samples using DTS method resulted in loss of anti-HCV reactivity for low-positive samples and did not generate enough volume for HCV RNA testing. Lyophilized samples tested positive for anti-HCV even after storage at 4 °C and 25 °C for 12 weeks. Further, HCV RNA was detectable in 5 of 5 (100%) samples over the course of 12 week storage at 4, 25, 37 and 45 °C. In conclusion, lyophilization of specimens maintains integrity of plasma samples for testing for markers of HCV infection and can be a potent mode of sharing proficiency samples without incurring huge shipping costs and avoids challenges with dry ice shipments between donor and recipient laboratories. Copyright © 2017. Published by Elsevier B.V.

  6. Kolmogorov-Smirnov test for spatially correlated data

    USGS Publications Warehouse

    Olea, R.A.; Pawlowsky-Glahn, V.

    2009-01-01

    The Kolmogorov-Smirnov test is a convenient method for investigating whether two underlying univariate probability distributions can be regarded as undistinguishable from each other or whether an underlying probability distribution differs from a hypothesized distribution. Application of the test requires that the sample be unbiased and the outcomes be independent and identically distributed, conditions that are violated in several degrees by spatially continuous attributes, such as topographical elevation. A generalized form of the bootstrap method is used here for the purpose of modeling the distribution of the statistic D of the Kolmogorov-Smirnov test. The innovation is in the resampling, which in the traditional formulation of bootstrap is done by drawing from the empirical sample with replacement presuming independence. The generalization consists of preparing resamplings with the same spatial correlation as the empirical sample. This is accomplished by reading the value of unconditional stochastic realizations at the sampling locations, realizations that are generated by simulated annealing. The new approach was tested by two empirical samples taken from an exhaustive sample closely following a lognormal distribution. One sample was a regular, unbiased sample while the other one was a clustered, preferential sample that had to be preprocessed. Our results show that the p-value for the spatially correlated case is always larger that the p-value of the statistic in the absence of spatial correlation, which is in agreement with the fact that the information content of an uncorrelated sample is larger than the one for a spatially correlated sample of the same size. ?? Springer-Verlag 2008.

  7. Detecting and enumerating soil-transmitted helminth eggs in soil: New method development and results from field testing in Kenya and Bangladesh.

    PubMed

    Steinbaum, Lauren; Kwong, Laura H; Ercumen, Ayse; Negash, Makeda S; Lovely, Amira J; Njenga, Sammy M; Boehm, Alexandria B; Pickering, Amy J; Nelson, Kara L

    2017-04-01

    Globally, about 1.5 billion people are infected with at least one species of soil-transmitted helminth (STH). Soil is a critical environmental reservoir of STH, yet there is no standard method for detecting STH eggs in soil. We developed a field method for enumerating STH eggs in soil and tested the method in Bangladesh and Kenya. The US Environmental Protection Agency (EPA) method for enumerating Ascaris eggs in biosolids was modified through a series of recovery efficiency experiments; we seeded soil samples with a known number of Ascaris suum eggs and assessed the effect of protocol modifications on egg recovery. We found the use of 1% 7X as a surfactant compared to 0.1% Tween 80 significantly improved recovery efficiency (two-sided t-test, t = 5.03, p = 0.007) while other protocol modifications-including different agitation and flotation methods-did not have a significant impact. Soil texture affected the egg recovery efficiency; sandy samples resulted in higher recovery compared to loamy samples processed using the same method (two-sided t-test, t = 2.56, p = 0.083). We documented a recovery efficiency of 73% for the final improved method using loamy soil in the lab. To field test the improved method, we processed soil samples from 100 households in Bangladesh and 100 households in Kenya from June to November 2015. The prevalence of any STH (Ascaris, Trichuris or hookworm) egg in soil was 78% in Bangladesh and 37% in Kenya. The median concentration of STH eggs in soil in positive samples was 0.59 eggs/g dry soil in Bangladesh and 0.15 eggs/g dry soil in Kenya. The prevalence of STH eggs in soil was significantly higher in Bangladesh than Kenya (chi-square, χ2 = 34.39, p < 0.001) as was the concentration (Mann-Whitney, z = 7.10, p < 0.001). This new method allows for detecting STH eggs in soil in low-resource settings and could be used for standardizing soil STH detection globally.

  8. Systems and methods for laser assisted sample transfer to solution for chemical analysis

    DOEpatents

    Van Berkel, Gary J.; Kertesz, Vilmos; Ovchinnikova, Olga S.

    2014-06-03

    Systems and methods are described for laser ablation of an analyte from a specimen and capturing of the analyte in a dispensed solvent to form a testing solution. A solvent dispensing and extraction system can form a liquid microjunction with the specimen. The solvent dispensing and extraction system can include a surface sampling probe. The laser beam can be directed through the surface sampling probe. The surface sampling probe can also serve as an atomic force microscopy probe. The surface sampling probe can form a seal with the specimen. The testing solution including the analyte can then be analyzed using an analytical instrument or undergo further processing.

  9. Systems and methods for laser assisted sample transfer to solution for chemical analysis

    DOEpatents

    Van Berkel, Gary J.; Kertesz, Vilmos; Ovchinnikova, Olga S.

    2015-09-29

    Systems and methods are described for laser ablation of an analyte from a specimen and capturing of the analyte in a dispensed solvent to form a testing solution. A solvent dispensing and extraction system can form a liquid microjunction with the specimen. The solvent dispensing and extraction system can include a surface sampling probe. The laser beam can be directed through the surface sampling probe. The surface sampling probe can also serve as an atomic force microscopy probe. The surface sampling probe can form a seal with the specimen. The testing solution including the analyte can then be analyzed using an analytical instrument or undergo further processing.

  10. Systems and methods for laser assisted sample transfer to solution for chemical analysis

    DOEpatents

    Van Berkel, Gary J; Kertesz, Vilmos; Ovchinnikova, Olga S

    2013-08-27

    Systems and methods are described for laser ablation of an analyte from a specimen and capturing of the analyte in a dispensed solvent to form a testing solution. A solvent dispensing and extraction system can form a liquid microjunction with the specimen. The solvent dispensing and extraction system can include a surface sampling probe. The laser beam can be directed through the surface sampling probe. The surface sampling probe can also serve as an atomic force microscopy probe. The surface sampling probe can form a seal with the specimen. The testing solution including the analyte can then be analyzed using an analytical instrument or undergo further processing.

  11. Discussion of and reply to ``The search for an accurate and practical means for testing residue from combustion of municipal solid waste for percent combustibles and energy content``

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eppich, J.D.; Hecklinger, R.S.

    1995-11-01

    This paper by Roger S. Hecklinger is a good contribution to the understanding of municipal solid waste combustion. The traditional test methods used on residue testing were summarized in a clear manner. Mr. Hecklinger describes sampling problems using coal and coke ash testing methods, which are similar to those experienced in testing the solid waste itself for its fuel content. The author gives several comments regarding the importance of the sampling program. This article also contains the original author`s reply to the comments and questions.

  12. 40 CFR 80.8 - Sampling methods for gasoline and diesel fuel.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... applicable procedures specified in American Society for Testing and Materials (ASTM) method D 4057-95(2000... applicable procedures specified in ASTM method D 4177-95(2000), entitled “Standard Practice for Automatic... applicable procedures in ASTM method D 5842-95(2000), entitled “Standard Practice for Sampling and Handling...

  13. Novel hybrid cryo-radial method: an emerging alternative to CT-guided biopsy in suspected lung cancer. A prospective case series and description of technique.

    PubMed

    Herath, Samantha; Yap, Elaine

    2018-02-01

    In diagnosing peripheral pulmonary lesions (PPL), radial endobronchial ultrasound (R-EBUS) is emerging as a safer method in comparison to CT-guided biopsy. Despite the better safety profile, the yield of R-EBUS remains lower (73%) than CT-guided biopsy (90%) due to the smaller size of samples. We adopted a hybrid method by adding cryobiopsy via the R-EBUS Guide Sheath (GS) to produce larger, non-crushed samples to improve diagnostic capability and enhance molecular testing. We report six prospective patients who underwent this procedure in our institution. R-EBUS samples were obtained via conventional sampling methods (needle aspiration, forceps biopsy, and cytology brush), followed by a cryobiopsy. An endobronchial blocker was placed near the planned area of biopsy in advance and inflated post-biopsy to minimize the risk of bleeding in all patients. A chest X-ray was performed 1 h post-procedure. All the PPLs were visualized with R-EBUS. The mean diameter of cryobiopsy samples was twice the size of forceps biopsy samples. In four patients, cryobiopsy samples were superior in size and the number of malignant cells per high power filed and was the preferred sample selected for mutation analysis and molecular testing. There was no pneumothorax or significant bleeding to report. Cryobiopsy samples were consistently larger and were the preferred samples for molecular testing, with an increase in the diagnostic yield and reduction in the need for repeat procedures, without hindering the marked safety profile of R-EBUS. Using an endobronchial blocker improves the safety of this procedure.

  14. A ricin forensic profiling approach based on a complex set of biomarkers.

    PubMed

    Fredriksson, Sten-Åke; Wunschel, David S; Lindström, Susanne Wiklund; Nilsson, Calle; Wahl, Karen; Åstot, Crister

    2018-08-15

    A forensic method for the retrospective determination of preparation methods used for illicit ricin toxin production was developed. The method was based on a complex set of biomarkers, including carbohydrates, fatty acids, seed storage proteins, in combination with data on ricin and Ricinus communis agglutinin. The analyses were performed on samples prepared from four castor bean plant (R. communis) cultivars by four different sample preparation methods (PM1-PM4) ranging from simple disintegration of the castor beans to multi-step preparation methods including different protein precipitation methods. Comprehensive analytical data was collected by use of a range of analytical methods and robust orthogonal partial least squares-discriminant analysis- models (OPLS-DA) were constructed based on the calibration set. By the use of a decision tree and two OPLS-DA models, the sample preparation methods of test set samples were determined. The model statistics of the two models were good and a 100% rate of correct predictions of the test set was achieved. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. 40 CFR 1048.515 - What are the field-testing procedures?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... CFR part 1065, subpart J, we describe the equipment and sampling methods for testing engines in the... specify in § 1048.101(c) for any continuous sampling period of at least 120 seconds under the following ranges of operation and operating conditions: (1) Engine operation during the emission sampling period...

  16. Efficacy of a lead based paint XRF analyzer and a commercially available colorimetric lead test kit as qualitative field tools for determining presence of lead in religious powders.

    PubMed

    Shah, Manthan P; Shendell, Derek G; Meng, Qingyu; Ohman-Strickland, Pamela; Halperin, William

    2018-04-23

    The performances of a portable X-Ray Fluorescence (XRF) lead paint analyzer (RMD LPA-1, Protec Instrument Corp., Waltham, MA) and a commercially available colorimetric lead test kit (First Alert Lead Test Kit, eAccess Solutions, Inc., Palatine, IL) were evaluated for use by local or state health departments as potential cost-effective rapid analysis or "spot test" field techniques for tentative identification of lead content in sindoor powders. For both field-sampling methods, sensitivity, specificity and predictive values varied widely for samples containing <300,000 μg/g lead. For samples containing ≥300,000 μg/g lead, the aforementioned metrics were 100% (however, the CIs had a wide range). In addition, both field sampling methods showed clear, consistent positive readings only for samples containing ≥300,000 μg/g lead. Even samples with lead content as high as 5,110 μg/g were not positively identified by either field analysis technique. The results of this study suggest the XRF analyzer and colorimetric lead test kit cannot be used as a rapid field test for sindoor by health department inspectors.

  17. Methods of human body odor sampling: the effect of freezing.

    PubMed

    Lenochova, Pavlina; Roberts, S Craig; Havlicek, Jan

    2009-02-01

    Body odor sampling is an essential tool in human chemical ecology research. However, methodologies of individual studies vary widely in terms of sampling material, length of sampling, and sample processing. Although these differences might have a critical impact on results obtained, almost no studies test validity of current methods. Here, we focused on the effect of freezing samples between collection and use in experiments involving body odor perception. In 2 experiments, we tested whether axillary odors were perceived differently by raters when presented fresh or having been frozen and whether several freeze-thaw cycles affected sample quality. In the first experiment, samples were frozen for 2 weeks, 1 month, or 4 months. We found no differences in ratings of pleasantness, attractiveness, or masculinity between fresh and frozen samples. Similarly, almost no differences between repeatedly thawed and fresh samples were found. We found some variations in intensity; however, this was unrelated to length of storage. The second experiment tested differences between fresh samples and those frozen for 6 months. Again no differences in subjective ratings were observed. These results suggest that freezing has no significant effect on perceived odor hedonicity and that samples can be reliably used after storage for relatively long periods.

  18. Jaccard distance based weighted sparse representation for coarse-to-fine plant species recognition.

    PubMed

    Zhang, Shanwen; Wu, Xiaowei; You, Zhuhong

    2017-01-01

    Leaf based plant species recognition plays an important role in ecological protection, however its application to large and modern leaf databases has been a long-standing obstacle due to the computational cost and feasibility. Recognizing such limitations, we propose a Jaccard distance based sparse representation (JDSR) method which adopts a two-stage, coarse to fine strategy for plant species recognition. In the first stage, we use the Jaccard distance between the test sample and each training sample to coarsely determine the candidate classes of the test sample. The second stage includes a Jaccard distance based weighted sparse representation based classification(WSRC), which aims to approximately represent the test sample in the training space, and classify it by the approximation residuals. Since the training model of our JDSR method involves much fewer but more informative representatives, this method is expected to overcome the limitation of high computational and memory costs in traditional sparse representation based classification. Comparative experimental results on a public leaf image database demonstrate that the proposed method outperforms other existing feature extraction and SRC based plant recognition methods in terms of both accuracy and computational speed.

  19. Quality assessment of internet pharmaceutical products using traditional and non-traditional analytical techniques.

    PubMed

    Westenberger, Benjamin J; Ellison, Christopher D; Fussner, Andrew S; Jenney, Susan; Kolinski, Richard E; Lipe, Terra G; Lyon, Robbe C; Moore, Terry W; Revelle, Larry K; Smith, Anjanette P; Spencer, John A; Story, Kimberly D; Toler, Duckhee Y; Wokovich, Anna M; Buhse, Lucinda F

    2005-12-08

    This work investigated the use of non-traditional analytical methods to evaluate the quality of a variety of pharmaceutical products purchased via internet sites from foreign sources and compared the results with those obtained from conventional quality assurance methods. Traditional analytical techniques employing HPLC for potency, content uniformity, chromatographic purity and drug release profiles were used to evaluate the quality of five selected drug products (fluoxetine hydrochloride, levothyroxine sodium, metformin hydrochloride, phenytoin sodium, and warfarin sodium). Non-traditional techniques, such as near infrared spectroscopy (NIR), NIR imaging and thermogravimetric analysis (TGA), were employed to verify the results and investigate their potential as alternative testing methods. Two of 20 samples failed USP monographs for quality attributes. The additional analytical methods found 11 of 20 samples had different formulations when compared to the U.S. product. Seven of the 20 samples arrived in questionable containers, and 19 of 20 had incomplete labeling. Only 1 of the 20 samples had final packaging similar to the U.S. products. The non-traditional techniques complemented the traditional techniques used and highlighted additional quality issues for the products tested. For example, these methods detected suspect manufacturing issues (such as blending), which were not evident from traditional testing alone.

  20. Field studies: Test method for on-line continuous measurement of total hydrocarbons (THC) and non-methane hydrocarbons (NMHC) in stack gas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hsiao, H.H.; Lai, C.C.; Chu, H.W.

    A new method for on-line monitoring of total hydrocarbons and non-methane hydrocarbons in stack gas simultaneously was developed in this study. Based on the principle of on-line GC/FID, the method was developed and can be considered as a new modification of the Method 25 and 25A of US EPA. Major advantages of the method included (1) capability of distinguishing methane as Method 25; (2) near-real-time results; (3) broad species coverage; (4) monitoring methane in straightforward manner; (5) low operation and maintenance costs. In the proposed method, test samples were continuously pumped from detection sources and loaded with a two-loop samplingmore » valve. The samples were then injected into two GC columns-empty and molecular sieve columns. The empty column was used for detection of THC, and the molecular sieve column was for methane. The detector in this GC was FID. NMHC concentration was obtained by subtracting methane from THC. The tests were carried out to measure the THC and methane in waste gas in various industries, including surface coating, semiconductor manufacturing, synthetic leather industries. Recovery rates of THC in the samples were between 86% to 114% for about 100 m of transfer line of samples. For the standard gas, the recovery rate was about 101%, 6.6 % of measurement precision, and 88%--114% of accuracy. The results showed the promising and reliable measurement of the test method for THC and methane in waste gas.« less

  1. A spreadsheet template compatible with Microsoft Excel and iWork Numbers that returns the simultaneous confidence intervals for all pairwise differences between multiple sample means.

    PubMed

    Brown, Angus M

    2010-04-01

    The objective of the method described in this paper is to develop a spreadsheet template for the purpose of comparing multiple sample means. An initial analysis of variance (ANOVA) test on the data returns F--the test statistic. If F is larger than the critical F value drawn from the F distribution at the appropriate degrees of freedom, convention dictates rejection of the null hypothesis and allows subsequent multiple comparison testing to determine where the inequalities between the sample means lie. A variety of multiple comparison methods are described that return the 95% confidence intervals for differences between means using an inclusive pairwise comparison of the sample means. 2009 Elsevier Ireland Ltd. All rights reserved.

  2. Sample size guidelines for fitting a lognormal probability distribution to censored most probable number data with a Markov chain Monte Carlo method.

    PubMed

    Williams, Michael S; Cao, Yong; Ebel, Eric D

    2013-07-15

    Levels of pathogenic organisms in food and water have steadily declined in many parts of the world. A consequence of this reduction is that the proportion of samples that test positive for the most contaminated product-pathogen pairings has fallen to less than 0.1. While this is unequivocally beneficial to public health, datasets with very few enumerated samples present an analytical challenge because a large proportion of the observations are censored values. One application of particular interest to risk assessors is the fitting of a statistical distribution function to datasets collected at some point in the farm-to-table continuum. The fitted distribution forms an important component of an exposure assessment. A number of studies have compared different fitting methods and proposed lower limits on the proportion of samples where the organisms of interest are identified and enumerated, with the recommended lower limit of enumerated samples being 0.2. This recommendation may not be applicable to food safety risk assessments for a number of reasons, which include the development of new Bayesian fitting methods, the use of highly sensitive screening tests, and the generally larger sample sizes found in surveys of food commodities. This study evaluates the performance of a Markov chain Monte Carlo fitting method when used in conjunction with a screening test and enumeration of positive samples by the Most Probable Number technique. The results suggest that levels of contamination for common product-pathogen pairs, such as Salmonella on poultry carcasses, can be reliably estimated with the proposed fitting method and samples sizes in excess of 500 observations. The results do, however, demonstrate that simple guidelines for this application, such as the proportion of positive samples, cannot be provided. Published by Elsevier B.V.

  3. A Comparison of EPI Sampling, Probability Sampling, and Compact Segment Sampling Methods for Micro and Small Enterprises

    PubMed Central

    Chao, Li-Wei; Szrek, Helena; Peltzer, Karl; Ramlagan, Shandir; Fleming, Peter; Leite, Rui; Magerman, Jesswill; Ngwenya, Godfrey B.; Pereira, Nuno Sousa; Behrman, Jere

    2011-01-01

    Finding an efficient method for sampling micro- and small-enterprises (MSEs) for research and statistical reporting purposes is a challenge in developing countries, where registries of MSEs are often nonexistent or outdated. This lack of a sampling frame creates an obstacle in finding a representative sample of MSEs. This study uses computer simulations to draw samples from a census of businesses and non-businesses in the Tshwane Municipality of South Africa, using three different sampling methods: the traditional probability sampling method, the compact segment sampling method, and the World Health Organization’s Expanded Programme on Immunization (EPI) sampling method. Three mechanisms by which the methods could differ are tested, the proximity selection of respondents, the at-home selection of respondents, and the use of inaccurate probability weights. The results highlight the importance of revisits and accurate probability weights, but the lesser effect of proximity selection on the samples’ statistical properties. PMID:22582004

  4. Evaluation of Nucleic Acid Preservation Cards for West Nile Virus Testing in Dead Birds

    PubMed Central

    Foss, Leslie; Reisen, William K.; Fang, Ying; Kramer, Vicki; Padgett, Kerry

    2016-01-01

    The California West Nile virus (WNV) Dead Bird Surveillance Program (DBSP) is an important component of WNV surveillance in the state. We evaluated FTA™ and RNASound™ cards as an alternative method for sampling dead birds for WNV molecular testing as these cards allow for more cost effective, rapid, and safer diagnostic sampling than the shipment of bird carcasses. To evaluate accuracy of results among avian sampling regimes, Reverse-Transcription Polymerase Chain Reaction (RT-PCR) results from FTA™ and RNASound™ cards were compared with results from kidney tissue, brain tissue, or oral swabs in lysis buffer in 2012–2013. In addition, RT-PCR results were compared with results from oral swabs tested by rapid antigen tests (RAMP™ and VecTOR™). While test results from the cards were not as sensitive as kidney tissue testing, they were more likely to provide accurate results than rapid antigen tests, and detected WNV in corvids as well as in other passerines, raptors, and waterfowl. Overall, WNV RT-PCR cycle threshold (Ct) scores from the cards were higher than those from tissue testing, but both card products displayed high sensitivity and specificity. American Crow samples provided the highest sensitivity. The cards also proved to be easier and more convenient vehicles for collecting and shipping samples, and in 2014 our program launched use of RNASound™ cards in the DBSP. Both FTA™ and RNASound™ products displayed 96% agreement with tissue results and are an adequate alternative sampling method for WNV dead bird testing. PMID:27341492

  5. Determination of Slake Durability Index (Sdi) Values on Different Shape of Laminated Marl Samples

    NASA Astrophysics Data System (ADS)

    Ankara, Hüseyin; Çiçek, Fatma; Talha Deniz, İsmail; Uçak, Emre; Yerel Kandemir, Süheyla

    2016-10-01

    The slake durability index (SDI) test is widely used to determine the disintegration characteristic of the weak and clay-bearing rocks in geo-engineering problems. However, due to the different shapes of sample pieces, such as, irregular shapes displayed mechanical breakages in the slaking process, the SDI test has some limitations that affect the index values. In addition, shape and surface roughness of laminated marl samples have a severe influence on the SDI. In this study, a new sample preparation method called Pasha Method was used to prepare spherical specimens from the laminated marl collected from Seyitomer collar (SLI). Moreover the SDI tests were performed on equal size and weight specimens: three sets with different shapes were used. The three different sets were prepared as the test samples which had sphere shape, parallel to the layers in irregular shape, and vertical to the layers in irregular shape. Index values were determined for the three different sets subjected to the SDI test for 4 cycles. The index values at the end of fourth cycle were found to be 98.43, 98.39 and 97.20 %, respectively. As seen, the index values of the sphere sample set were found to be higher than irregular sample sets.

  6. How conservative is Fisher's exact test? A quantitative evaluation of the two-sample comparative binomial trial.

    PubMed

    Crans, Gerald G; Shuster, Jonathan J

    2008-08-15

    The debate as to which statistical methodology is most appropriate for the analysis of the two-sample comparative binomial trial has persisted for decades. Practitioners who favor the conditional methods of Fisher, Fisher's exact test (FET), claim that only experimental outcomes containing the same amount of information should be considered when performing analyses. Hence, the total number of successes should be fixed at its observed level in hypothetical repetitions of the experiment. Using conditional methods in clinical settings can pose interpretation difficulties, since results are derived using conditional sample spaces rather than the set of all possible outcomes. Perhaps more importantly from a clinical trial design perspective, this test can be too conservative, resulting in greater resource requirements and more subjects exposed to an experimental treatment. The actual significance level attained by FET (the size of the test) has not been reported in the statistical literature. Berger (J. R. Statist. Soc. D (The Statistician) 2001; 50:79-85) proposed assessing the conservativeness of conditional methods using p-value confidence intervals. In this paper we develop a numerical algorithm that calculates the size of FET for sample sizes, n, up to 125 per group at the two-sided significance level, alpha = 0.05. Additionally, this numerical method is used to define new significance levels alpha(*) = alpha+epsilon, where epsilon is a small positive number, for each n, such that the size of the test is as close as possible to the pre-specified alpha (0.05 for the current work) without exceeding it. Lastly, a sample size and power calculation example are presented, which demonstrates the statistical advantages of implementing the adjustment to FET (using alpha(*) instead of alpha) in the two-sample comparative binomial trial. 2008 John Wiley & Sons, Ltd

  7. Results of the first provisional technical secretariat interlaboratory comparison test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stuff, J.R.; Hoffland, L.

    1995-06-01

    The principal task of this laboratory in the first Provisional Technical Secretariat (PTS) Interlaboratory Comparison Test was to verify and test the extraction and preparation procedures outlined in the Recommended Operating Procedures for Sampling and Analysis in the Verification of Chemical Disarmament in addition to our laboratory extraction methods and our laboratory analysis methods. Sample preparation began on 16 May 1994 and analysis was completed on 12 June 1994. The analytical methods used included NMR ({sup 1}H and {sup 31}P) GC/AED, GC/MS (EI and methane CI), GC/IRD, HPLC/IC, HPLC/TSP/MS, MS/MS(Electrospray), and CZE.

  8. Evaluation of sampling methods for toxicological testing of indoor air particulate matter.

    PubMed

    Tirkkonen, Jenni; Täubel, Martin; Hirvonen, Maija-Riitta; Leppänen, Hanna; Lindsley, William G; Chen, Bean T; Hyvärinen, Anne; Huttunen, Kati

    2016-09-01

    There is a need for toxicity tests capable of recognizing indoor environments with compromised air quality, especially in the context of moisture damage. One of the key issues is sampling, which should both provide meaningful material for analyses and fulfill requirements imposed by practitioners using toxicity tests for health risk assessment. We aimed to evaluate different existing methods of sampling indoor particulate matter (PM) to develop a suitable sampling strategy for a toxicological assay. During three sampling campaigns in moisture-damaged and non-damaged school buildings, we evaluated one passive and three active sampling methods: the Settled Dust Box (SDB), the Button Aerosol Sampler, the Harvard Impactor and the National Institute for Occupational Safety and Health (NIOSH) Bioaerosol Cyclone Sampler. Mouse RAW264.7 macrophages were exposed to particle suspensions and cell metabolic activity (CMA), production of nitric oxide (NO) and tumor necrosis factor (TNFα) were determined after 24 h of exposure. The repeatability of the toxicological analyses was very good for all tested sampler types. Variability within the schools was found to be high especially between different classrooms in the moisture-damaged school. Passively collected settled dust and PM collected actively with the NIOSH Sampler (Stage 1) caused a clear response in exposed cells. The results suggested the higher relative immunotoxicological activity of dust from the moisture-damaged school. The NIOSH Sampler is a promising candidate for the collection of size-fractionated PM to be used in toxicity testing. The applicability of such sampling strategy in grading moisture damage severity in buildings needs to be developed further in a larger cohort of buildings.

  9. A simple modification of the Baermann method for diagnosis of strongyloidiasis.

    PubMed

    Hernández-Chavarría, F; Avendaño, L

    2001-08-01

    The diagnosis of Strongyloides stercoralis infections is routinely made by microscopic observation of larvae in stool samples, a low sensitivity method, or by other, most effective methods, such as the Baermann or agar culture plate methods. We propose in this paper a practical modification of Baermann method. One hundred and six stool samples from alcoholic patients were analyzed using the direct smear test, agar culture plate method, the standard Baermann method, and its proposed modification. For this modification the funnel used in the original version of the method is substituted by a test tube with a rubber stopper, perforated to allow insertion of a pipette tip. The tube with a fecal suspension is inverted over another tube containing 6 ml of saline solution and incubated at 37 degrees C for at least 2 h. The saline solution from the second tube is centrifuged and the pellet is observed microscopically. Larva of S. stercoralis were detected in six samples (5.7%) by the two versions of the Baermann method. Five samples were positive using the agar culture plate method, and only in two samples the larva were observed using direct microscopic observation of fecal smears. Cysts of Endolimax nana and Entamoeba histolytica/dyspar were also detected in the modification of Baermann method. Data obtained by the modified Baermann method suggest that this methodology may helps concentrate larvae of S. stercoralis as efficiently as the original method.

  10. Application of the digital image correlation method in the study of cohesive coarse soil deformations

    NASA Astrophysics Data System (ADS)

    Kogut, Janusz P.; Tekieli, Marcin

    2018-04-01

    Non-contact video measurement methods are used to extend the capabilities of standard measurement systems, based on strain gauges or accelerometers. In most cases, they are able to provide more accurate information about the material or construction being tested than traditional sensors, while maintaining a high resolution and measurement stability. With the use of optical methods, it is possible to generate a full field of displacement on the surface of the test sample. The displacement value is the basic (primary) value determined using optical methods, and it is possible to determine the size of the derivative in the form of a sample deformation. This paper presents the application of a non-contact optical method to investigate the deformation of coarse soil material. For this type of soil, it is particularly difficult to obtain basic strength parameters. The use of a non-contact optical method, followed by a digital image correlation (DIC) study of the sample obtained during the tests, effectively completes the description of the behaviour of this type of material.

  11. Static renewal tests using Anodonta imbecillis (freshwater mussels). Anodonta imbecillis QA test 1, Clinch River-Environmental Restoration Program (CR-ERP)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simbeck, D.J.

    1993-12-31

    Toxicity testing of split whole sediment samples using juvenile freshwater mussels (Anodonta imbecillis) was conducted by TVA and CR-ERP personnel as part of the CR-ERP biomonitoring study of Clinch River sediments to provide a quality assurance mechanism for test organism quality and overall performance of the test. In addition, testing included procedures comparing daily renewal versus non-renewal of test sediments. Testing of sediment samples collected July 15 from Poplar Creek Miles 6.0 and 5.1 was conducted from July 21--30, 1993. Results from this test showed no toxicity (survival effects) to fresh-water mussels during a 9-day exposure to the sediments. Sidemore » by side testing of sediments with daily sediment renewal and no sediment renewal showed no differences between methods. This may be due to the absence of toxicity in both samples and may not reflect true differences between the two methods for toxic sediment. Attachments to this report include: Chain of custody forms -- originals; Toxicity test bench sheets and statistical analyses; and Ammonia analysis request and results.« less

  12. Tensiometer, drive probe for use with environmental testing equipment, and methods of inserting environmental testing equipment into a sample

    DOEpatents

    Hubbell, Joel M.; Sisson, James B.

    2005-07-26

    A method of inserting a tensiometer into a sample, comprises providing a drive probe configured to be engaged by direct push equipment; supporting a porous member from the drive probe; and driving the drive probe into the sample using a cone penetrometer. A tensiometer comprises a drive probe configured to be engaged by direct push equipment or a cone penetrometer; a porous member supported by the drive probe; and a pressure sensor in pressure sensing relation to the porous member.

  13. Multi-Laboratory Study of Five Methods for the Determination of Brevetoxins in Shellfish Tissue Extracts.

    PubMed

    Dickey, Robert W; Plakas, Steven M; Jester, Edward L E; El Said, Kathleen R; Johannessen, Jan N; Flewelling, Leanne J; Scott, Paula; Hammond, Dan G; Van Dolah, Frances M; Leighfield, Tod A; Bottein Dachraoui, Marie-Yasmine; Ramsdell, John S; Pierce, Richard H; Henry, Mike S; Poli, Mark A; Walker, Calvin; Kurtz, Jan; Naar, Jerome; Baden, Daniel G; Musser, Steve M; White, Kevin D; Truman, Penelope; Miller, Aaron; Hawryluk, Timothy P; Wekell, Marleen M; Stirling, David; Quilliam, Michael A; Lee, Jung K

    A thirteen-laboratory comparative study tested the performance of four methods as alternatives to mouse bioassay for the determination of brevetoxins in shellfish. The methods were N2a neuroblastoma cell assay, two variations of the sodium channel receptor binding assay, competitive ELISA, and LC/MS. Three to five laboratories independently performed each method using centrally prepared spiked and naturally incurred test samples. Competitive ELISA and receptor binding (96-well format) compared most favorably with mouse bioassay. Between-laboratory relative standard deviations (RSDR) ranged from 10 to 20% for ELISA and 14 to 31% for receptor binding. Within-laboratory (RSDr) ranged from 6 to 15% for ELISA, and 5 to 31% for receptor binding. Cell assay was extremely sensitive but data variation rendered it unsuitable for statistical treatment. LC/MS performed as well as ELISA on spiked test samples but was inordinately affected by lack of toxin-metabolite standards, uniform instrumental parameters, or both, on incurred test samples. The ELISA and receptor binding assay are good alternatives to mouse bioassay for the determination of brevetoxins in shellfish.

  14. Instruments for Water Quality Monitoring

    ERIC Educational Resources Information Center

    Ballinger, Dwight G.

    1972-01-01

    Presents information regarding available instruments for industries and agencies who must monitor numerous aquatic parameters. Charts denote examples of parameters sampled, testing methods, range and accuracy of test methods, cost analysis, and reliability of instruments. (BL)

  15. The predictive validity of selection for entry into postgraduate training in general practice: evidence from three longitudinal studies

    PubMed Central

    Patterson, Fiona; Lievens, Filip; Kerrin, Máire; Munro, Neil; Irish, Bill

    2013-01-01

    Background The selection methodology for UK general practice is designed to accommodate several thousand applicants per year and targets six core attributes identified in a multi-method job-analysis study Aim To evaluate the predictive validity of selection methods for entry into postgraduate training, comprising a clinical problem-solving test, a situational judgement test, and a selection centre. Design and setting A three-part longitudinal predictive validity study of selection into training for UK general practice. Method In sample 1, participants were junior doctors applying for training in general practice (n = 6824). In sample 2, participants were GP registrars 1 year into training (n = 196). In sample 3, participants were GP registrars sitting the licensing examination after 3 years, at the end of training (n = 2292). The outcome measures include: assessor ratings of performance in a selection centre comprising job simulation exercises (sample 1); supervisor ratings of trainee job performance 1 year into training (sample 2); and licensing examination results, including an applied knowledge examination and a 12-station clinical skills objective structured clinical examination (OSCE; sample 3). Results Performance ratings at selection predicted subsequent supervisor ratings of job performance 1 year later. Selection results also significantly predicted performance on both the clinical skills OSCE and applied knowledge examination for licensing at the end of training. Conclusion In combination, these longitudinal findings provide good evidence of the predictive validity of the selection methods, and are the first reported for entry into postgraduate training. Results show that the best predictor of work performance and training outcomes is a combination of a clinical problem-solving test, a situational judgement test, and a selection centre. Implications for selection methods for all postgraduate specialties are considered. PMID:24267856

  16. Evaluation of Targeted Next-Generation Sequencing for Detection of Bovine Pathogens in Clinical Samples.

    PubMed

    Anis, Eman; Hawkins, Ian K; Ilha, Marcia R S; Woldemeskel, Moges W; Saliki, Jeremiah T; Wilkes, Rebecca P

    2018-07-01

    The laboratory diagnosis of infectious diseases, especially those caused by mixed infections, is challenging. Routinely, it requires submission of multiple samples to separate laboratories. Advances in next-generation sequencing (NGS) have provided the opportunity for development of a comprehensive method to identify infectious agents. This study describes the use of target-specific primers for PCR-mediated amplification with the NGS technology in which pathogen genomic regions of interest are enriched and selectively sequenced from clinical samples. In the study, 198 primers were designed to target 43 common bovine and small-ruminant bacterial, fungal, viral, and parasitic pathogens, and a bioinformatics tool was specifically constructed for the detection of targeted pathogens. The primers were confirmed to detect the intended pathogens by testing reference strains and isolates. The method was then validated using 60 clinical samples (including tissues, feces, and milk) that were also tested with other routine diagnostic techniques. The detection limits of the targeted NGS method were evaluated using 10 representative pathogens that were also tested by quantitative PCR (qPCR), and the NGS method was able to detect the organisms from samples with qPCR threshold cycle ( C T ) values in the 30s. The method was successful for the detection of multiple pathogens in the clinical samples, including some additional pathogens missed by the routine techniques because the specific tests needed for the particular organisms were not performed. The results demonstrate the feasibility of the approach and indicate that it is possible to incorporate NGS as a diagnostic tool in a cost-effective manner into a veterinary diagnostic laboratory. Copyright © 2018 Anis et al.

  17. Biodegradability Evaluation of Polymers by ISO 14855-2

    PubMed Central

    Funabashi, Masahiro; Ninomiya, Fumi; Kunioka, Masao

    2009-01-01

    Biodegradabilities of polymers and their composites in a controlled compost were described. Polycaprolactone (PCL) and poly(lactic acid) (PLA) were employed as biodegradable polymers. Biodegradabilities of PCL and PLA samples in a controlled compost were measured using a Microbial Oxidative Degradation Analyzer (MODA) according to ISO 14855-2. Sample preparation method for biodegradation test according to ISO/DIS 10210 was also described. Effects of sizes and shapes of samples on biodegradability were studied. Reproducibility of biodegradation test of ISO 14855-2 by MODA was confirmed. Validity of sample preparation method for polymer pellets, polymer film, and polymer products of ISO/DIS 10210 for ISO 14855-2 was confirmed. PMID:20111676

  18. Influences of Electrification and Salt on Hydrophobicity of Sample Surface in Dynamic Drop Test

    NASA Astrophysics Data System (ADS)

    Shiibara, Daiki; Arata, Yoshihiro; Haji, Kenichi; Miyake, Takuma; Sakoda, Tatsuya; Otsubo, Masahisa

    Studies on the development of deterioration/ performance evaluation method for outdoor electric insulation of polymer materials are pushed forward now in the International Council on Large Electric Systems (CIGRE). The small scale test method (Dynamic drop test; DDT) which could evaluate disappearance characteristics of hydrophobicity easily was suggested. This test is to evaluate resistance of a sample to loss of hydrophobicity due to moisture and simultaneous electric stress. As factors for deterioration of hydrophobicity on a sample in DDT, various factors such as electrical influence, physical influence by water droplets and so on were considered. In this study, we investigated two kinds of factors (electrification and salt) affecting deterioration of hydrophobicity on the surface of a silicone rubber until ignition of continuous electrical discharge in DDT.

  19. Residual antibiotics in decontaminated human cardiovascular tissues intended for transplantation and risk of falsely negative microbiological analyses.

    PubMed

    Buzzi, Marina; Guarino, Anna; Gatto, Claudio; Manara, Sabrina; Dainese, Luca; Polvani, Gianluca; Tóthová, Jana D'Amato

    2014-01-01

    We investigated the presence of antibiotics in cryopreserved cardiovascular tissues and cryopreservation media, after tissue decontamination with antibiotic cocktails, and the impact of antibiotic residues on standard tissue bank microbiological analyses. Sixteen cardiovascular tissues were decontaminated with bank-prepared cocktails and cryopreserved by two different tissue banks according to their standard operating procedures. Before and after decontamination, samples underwent microbiological analysis by standard tissue bank methods. Cryopreserved samples were tested again with and without the removal of antibiotic residues using a RESEP tube, after thawing. Presence of antibiotics in tissue homogenates and processing liquids was determined by a modified agar diffusion test. All cryopreserved tissue homogenates and cryopreservation media induced important inhibition zones on both Staphylococcus aureus- and Pseudomonas aeruginosa-seeded plates, immediately after thawing and at the end of the sterility test. The RESEP tube treatment markedly reduced or totally eliminated the antimicrobial activity of tested tissues and media. Based on standard tissue bank analysis, 50% of tissues were found positive for bacteria and/or fungi, before decontamination and 2 out of 16 tested samples (13%) still contained microorganisms after decontamination. After thawing, none of the 16 cryopreserved samples resulted positive with direct inoculum method. When the same samples were tested after removal of antibiotic residues, 8 out of 16 (50%) were contaminated. Antibiotic residues present in tissue allografts and processing liquids after decontamination may mask microbial contamination during microbiological analysis performed with standard tissue bank methods, thus resulting in false negatives.

  20. Residual Antibiotics in Decontaminated Human Cardiovascular Tissues Intended for Transplantation and Risk of Falsely Negative Microbiological Analyses

    PubMed Central

    Gatto, Claudio; Manara, Sabrina; Dainese, Luca; Polvani, Gianluca; Tóthová, Jana D'Amato

    2014-01-01

    We investigated the presence of antibiotics in cryopreserved cardiovascular tissues and cryopreservation media, after tissue decontamination with antibiotic cocktails, and the impact of antibiotic residues on standard tissue bank microbiological analyses. Sixteen cardiovascular tissues were decontaminated with bank-prepared cocktails and cryopreserved by two different tissue banks according to their standard operating procedures. Before and after decontamination, samples underwent microbiological analysis by standard tissue bank methods. Cryopreserved samples were tested again with and without the removal of antibiotic residues using a RESEP tube, after thawing. Presence of antibiotics in tissue homogenates and processing liquids was determined by a modified agar diffusion test. All cryopreserved tissue homogenates and cryopreservation media induced important inhibition zones on both Staphylococcus aureus- and Pseudomonas aeruginosa-seeded plates, immediately after thawing and at the end of the sterility test. The RESEP tube treatment markedly reduced or totally eliminated the antimicrobial activity of tested tissues and media. Based on standard tissue bank analysis, 50% of tissues were found positive for bacteria and/or fungi, before decontamination and 2 out of 16 tested samples (13%) still contained microorganisms after decontamination. After thawing, none of the 16 cryopreserved samples resulted positive with direct inoculum method. When the same samples were tested after removal of antibiotic residues, 8 out of 16 (50%) were contaminated. Antibiotic residues present in tissue allografts and processing liquids after decontamination may mask microbial contamination during microbiological analysis performed with standard tissue bank methods, thus resulting in false negatives. PMID:25397402

  1. Evaluation of VIDAS UP Listeria assay (LPT) for the detection of Listeria in a variety of foods and environmental surfaces: First Action 2013.10.

    PubMed

    Crowley, Erin; Bird, Patrick; Flannery, Jonathan; Benzinger, M Joseph; Fisher, Kiel; Boyle, Megan; Huffman, Travis; Bastin, Ben; Bedinghaus, Paige; Judd, William; Hoang, Thao; Agin, James; Goins, David; Johnson, Ronald L

    2014-01-01

    The VIDAS UP Listeria (LPT) is an automated rapid screening enzyme phage-ligand based assay for the detection of Listeria species in human food products and environmental samples. The VIDAS LPT method was compared in a multi-laboratory collaborative study to AOAC Official Method 993.12 Listeria monocytogenes in Milk and Dairy Products reference method following current AOAC guidelines. A total of 14 laboratories participated, representing government and industry, throughout the United States. One matrix, queso fresco (soft Mexican cheese), was analyzed using two different test portion sizes, 25 and 125 g. Samples representing each test portion size were artificially contaminated with Listeria species at three levels, an uninoculated control level [0 colony-forming units (CFU)/test portion], a low-inoculum level (0.2-2 CFU/test portion), and a high-inoculum level (2-5 CFU/test portion). For this evaluation, 1800 unpaired replicate test portions were analyzed by either the VIDAS LPT or AOAC 993.12. Each inoculation level was analyzed using the Probability of Detection (POD) statistical model. For the low-level inoculated test portions, difference in collaborator POD (dLPOD) values of 0.01, (-0.10, 0.13), with 95% confidence intervals, were obtained for both 25 and 125 g test portions. The range of the confidence intervals for dLPOD values for both the 25 and 125 g test portions contains the point 0.0 indicating no statistically significant difference in the number of positive samples detected between the VIDAS LPT and the AOAC methods. In addition to Oxford agar, VIDAS LPT test portions were confirmed using Agar Listeria Ottavani and Agosti (ALOA), a proprietary chromogenic agar for the identification and differentiation of L. monocytogenes and Listeria species. No differences were observed between the two selective agars. The VIDAS LPT method, with the optional ALOA agar confirmation method, was adopted as Official First Action status for the detection of Listeria species in a variety of foods and environmental samples.

  2. Power and Sample Size Calculations for Logistic Regression Tests for Differential Item Functioning

    ERIC Educational Resources Information Center

    Li, Zhushan

    2014-01-01

    Logistic regression is a popular method for detecting uniform and nonuniform differential item functioning (DIF) effects. Theoretical formulas for the power and sample size calculations are derived for likelihood ratio tests and Wald tests based on the asymptotic distribution of the maximum likelihood estimators for the logistic regression model.…

  3. Salmonella detection in poultry samples. Comparison of two commercial real-time PCR systems with culture methods for the detection of Salmonella spp. in environmental and fecal samples of poultry.

    PubMed

    Sommer, D; Enderlein, D; Antakli, A; Schönenbrücher, H; Slaghuis, J; Redmann, T; Lierz, M

    2012-01-01

    The efficiency of two commercial PCR methods based on real-time technology, the foodproof® Salmonella detection system and the BAX® PCR Assay Salmonella system was compared to standardized culture methods (EN ISO 6579:2002 - Annex D) for the detection of Salmonella spp. in poultry samples. Four sample matrices (feed, dust, boot swabs, feces) obtained directly from poultry flocks, as well as artificially spiked samples of the same matrices, were used. All samples were tested for Salmonella spp. using culture methods first as the gold standard. In addition samples spiked with Salmonella Enteridis were tested to evaluate the sensitivity of both PCR methods. Furthermore all methods were evaluated in an annual ring-trial of the National Salmonella Reference Laboratory of Germany. Salmonella detection in the matrices feed, dust and boot swabs were comparable in both PCR systems whereas the results from feces differed markedly. The quality, especially the freshness, of the fecal samples had an influence on the sensitivity of the real-time PCR and the results of the culture methods. In fresh fecal samples an initial spiking level of 100cfu/25g Salmonella Enteritidis was detected. Two-days-dried fecal samples allowed the detection of 14cfu/25g. Both real- time PCR protocols appear to be suitable for the detection of Salmonella spp. in all four matrices. The foodproof® system detected eight samples more to be positive compared to the BAX® system, but had a potential false positive result in one case. In 7-days-dried samples none of the methods was able to detect Salmonella likely through letal cell damage. In general the advantage of PCR analyses over the culture method is the reduction of working time from 4-5 days to only 2 days. However, especially for the analysis of fecal samples official validation should be conducted according to the requirement of EN ISO6579:2002 - Annex D.

  4. EGFR Mutation Testing Practices within the Asia Pacific Region

    PubMed Central

    Kerr, Keith M.; Utomo, Ahmad; Rajadurai, Pathmanathan; Tran, Van Khanh; Du, Xiang; Chou, Teh-Ying; Enriquez, Ma. Luisa D.; Lee, Geon Kook; Iqbal, Jabed; Shuangshoti, Shanop; Chung, Jin-Haeng; Hagiwara, Koichi; Liang, Zhiyong; Normanno, Nicola; Park, Keunchil; Toyooka, Shinichi; Tsai, Chun-Ming; Waring, Paul; Zhang, Li; McCormack, Rose; Ratcliffe, Marianne; Itoh, Yohji; Sugeno, Masatoshi; Mok, Tony

    2015-01-01

    Introduction: The efficacy of epidermal growth factor receptor (EGFR) tyrosine kinase inhibitors in EGFR mutation-positive non–small-cell lung cancer (NSCLC) patients necessitates accurate, timely testing. Although EGFR mutation testing has been adopted by many laboratories in Asia, data are lacking on the proportion of NSCLC patients tested in each country, and the most commonly used testing methods. Methods: A retrospective survey of records from NSCLC patients tested for EGFR mutations during 2011 was conducted in 11 Asian Pacific countries at 40 sites that routinely performed EGFR mutation testing during that period. Patient records were used to complete an online questionnaire at each site. Results: Of the 22,193 NSCLC patient records surveyed, 31.8% (95% confidence interval: 31.2%–32.5%) were tested for EGFR mutations. The rate of EGFR mutation positivity was 39.6% among the 10,687 cases tested. The majority of samples were biopsy and/or cytology samples (71.4%). DNA sequencing was the most commonly used testing method accounting for 40% and 32.5% of tissue and cytology samples, respectively. A pathology report was available only to 60.0% of the sites, and 47.5% were not members of a Quality Assurance Scheme. Conclusions: In 2011, EGFR mutation testing practices varied widely across Asia. These data provide a reference platform from which to improve the molecular diagnosis of NSCLC, and EGFR mutation testing in particular, in Asia. PMID:25376513

  5. Validation of a hospital-laboratory workstation for immunohematologic methods.

    PubMed

    Schoenfeld, Helge; Pretzel, Karin J; von Heymann, Christian; Neuner, Bruno; Kalus, Ulrich; Kiesewetter, Holger; Pruss, Axel

    2010-01-01

    The FREELYS Nano system (Diagast) is a manual workstation for ABO/D grouping, Rh phenotyping, K typing, and antibody screening (ABS) for immunoglobulin G (IgG) antibodies only and works with the erythrocyte-magnetized technology (EMT). The principle of EMT is based on magnetization of red blood cells and avoids centrifugation and washing steps. A total of 304 samples were tested with our routine blood bank methods, 100 samples for ABO/D grouping, 196 samples (100 at first evaluation, 96 at second evaluation) for Rh phenotyping and K typing (PK7200, Olympus), and 108 samples for ABS (DiaMed). All samples were tested in parallel with the FREELYS Nano. We found a 100% concordance between the observed (FREELYS Nano) and the expected (Olympus PK7200) results for ABO/D grouping in all 100 samples. For Rh phenotyping and K tests, in 24 of 100 samples false-positive reactions were observed in the first evaluation by the FREELYS Nano. After changing the test kit batch for Rh phenotyping by the manufacturer, a complete concordance in Rh phenotyping and K tests was observed in a second evaluation. For ABS, the FREELYS Nano showed in 4 of 108 samples (3.7%) false-negative reactions for IgG antibodies (two anti-K, one anti-E, one anti-C(w)), and one (0.9%) false-positive reaction. The FREELYS Nano is reliably suited to ABO/D grouping, Rh phenotyping, and K testing. The rate of false-negative reactions for IgG antibodies should be reduced.

  6. Final Report, Volume 2, The Development of Qualification Standards for Cast Duplex Stainless Steel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Russell, Steven, W.; Lundin, Carl, W.

    2005-09-30

    The scope of testing cast Duplex Stainless Steel (DSS) required testing to several ASTM specifications, while formulating and conducting industry round robin tests to verify and study the reproducibility of the results. ASTM E562 (Standard Test Method for Determining Volume Fraction by Systematic manual Point Count) and ASTM A923 (Standard Test Methods for Detecting Detrimental Intermetallic Phase in Wrought Duplex Austenitic/Ferritic Stainless Steels) were the specifications utilized in conducting this work. An ASTM E562 industry round robin, ASTM A923 applicability study, ASTM A923 industry round robin, and an ASTM A923 study of the effectiveness of existing foundry solution annealing proceduresmore » for producing cast DSS without intermetallic phases were implemented. In the ASTM E562 study, 5 samples were extracted from various cast austenitic and DSS in order to have varying amounts of ferrite. Each sample was metallographically prepared by UT and sent to each of 8 participants for volume fraction of ferrite measurements. Volume fraction of ferrite was measured using manual point count per ASTM E562. FN was measured from the Feritescope® and converted to volume fraction of ferrite. Results indicate that ASTM E562 is applicable to DSS and the results have excellent lab-to-lab reproducibility. Also, volume fraction of ferrite conversions from the FN measured by the Feritescope® were similar to volume fraction of ferrite measured per ASTM E562. In the ASTM A923 applicability to cast DSS study, 8 different heat treatments were performed on 3 lots of ASTM A890-4A (CD3MN) castings and 1 lot of 2205 wrought DSS. The heat treatments were selected to produce a wide range of cooling rates and hold times in order to study the suitability of ASTM A923 to the response of varying amounts on intermetallic phases [117]. The test parameters were identical to those used to develop ASTM A923 for wrought DSS. Charpy V-notch impact samples were extracted from the castings and wrought DSS and tested per ASTM A923 method B (Charpy impact test). Method A (sodium hydroxide etch test) was performed on one half of a fractured Charpy V-notch impact sample and Method C (ferric chloride corrosion weight loss test) was performed on another half. Test results for the three cast lots and one wrought lot indicate that ASTM A923 is relevant for detecting intermetallic phases in cast DSS. In the ASTM A923 round robin study, five laboratories conducted ASTM A923 Methods A & C on cast DSS material and the lab-to-lab reproducibility of the data was determined. Two groups of samples were sent to the participants. Group 1 samples were tested per ASTM A923 Method A, group 2 samples were tested by ASTM A923 Method C. Testing procedures for this round robin study were identical to those used in the ASTM A923 applicability study. Results from this round robin indicate that there is excellent lab-to-lab reproducibility of ASTM A923 with respect to cast DSS and that ASTM A923 could be expanded to cover both wrought and cast DSS. In the ASTM A923 study of the effectiveness of existing foundry solution annealing procedures for producing cast DSS without intermetallic phases, Ten heats of ASTM A890-4A (CD3MN) in the foundry solution annealed condition were tested per ASTM A923 Methods A, B, & C. Testing of these materials per ASTM A923 was used to determine if the foundry solution anneal procedures were adequate to completely eliminate any intermetallic phases, which may have precipitated during the casting and subsequent heat treatment processes. All heats showed no sign of intermetallic phase per Method A, passed minimum Charpy impact energy requirements per Method B (> 40 ft-lbs @ -40°C (-40°F)), and showed negligible weight loss per Method C (< 10 mdd). These results indicate that the solution annealing procedure used by foundries is adequate to produce a product free from intermetallic phases.« less

  7. Final Report, Volume 2, The Development of Qualification Standards for Cast Duplex Stainless Steel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Russell, Steven, W.; Lundin, Carl, D.

    2005-09-30

    The scope of testing cast Duplex Stainless Steel (DSS) required testing to several ASTM specifications, while formulating and conducting industry round robin tests to verify and study the reproducibility of the results. ASTM E562 (Standard Test Method for Determining Volume Fraction by Systematic manual Point Count) and ASTM A923 (Standard Test Methods for Detecting Detrimental Intermetallic Phase in Wrought Duplex Austenitic/Ferritic Stainless Steels) were the specifications utilized in conducting this work. An ASTM E562 industry round robin, ASTM A923 applicability study, ASTM A923 industry round robin, and an ASTM A923 study of the effectiveness of existing foundry solution annealing proceduresmore » for producing cast DSS without intermetallic phases were implemented. In the ASTM E562 study, 5 samples were extracted from various cast austenitic and DSS in order to have varying amounts of ferrite. Each sample was metallographically prepared by UT and sent to each of 8 participants for volume fraction of ferrite measurements. Volume fraction of ferrite was measured using manual point count per ASTM E562. FN was measured from the Feritescope{reg_sign} and converted to volume fraction of ferrite. Results indicate that ASTM E562 is applicable to DSS and the results have excellent lab-to-lab reproducibility. Also, volume fraction of ferrite conversions from the FN measured by the Feritescope{reg_sign} were similar to volume fraction of ferrite measured per ASTM E562. In the ASTM A923 applicability to cast DSS study, 8 different heat treatments were performed on 3 lots of ASTM A890-4A (CD3MN) castings and 1 lot of 2205 wrought DSS. The heat treatments were selected to produce a wide range of cooling rates and hold times in order to study the suitability of ASTM A923 to the response of varying amounts on intermetallic phases [117]. The test parameters were identical to those used to develop ASTM A923 for wrought DSS. Charpy V-notch impact samples were extracted from the castings and wrought DSS and tested per ASTM A923 method B (Charpy impact test). Method A (sodium hydroxide etch test) was performed on one half of a fractured Charpy V-notch impact sample and Method C (ferric chloride corrosion weight loss test) was performed on another half. Test results for the three cast lots and one wrought lot indicate that ASTM A923 is relevant for detecting intermetallic phases in cast DSS. In the ASTM A923 round robin study, five laboratories conducted ASTM A923 Methods A & C on cast DSS material and the lab-to-lab reproducibility of the data was determined. Two groups of samples were sent to the participants. Group 1 samples were tested per ASTM A923 Method A, group 2 samples were tested by ASTM A923 Method C. Testing procedures for this round robin study were identical to those used in the ASTM A923 applicability study. Results from this round robin indicate that there is excellent lab-to-lab reproducibility of ASTM A923 with respect to cast DSS and that ASTM A923 could be expanded to cover both wrought and cast DSS. In the ASTM A923 study of the effectiveness of existing foundry solution annealing procedures for producing cast DSS without intermetallic phases, Ten heats of ASTM A890-4A (CD3MN) in the foundry solution annealed condition were tested per ASTM A923 Methods A, B, & C. Testing of these materials per ASTM A923 was used to determine if the foundry solution anneal procedures were adequate to completely eliminate any intermetallic phases, which may have precipitated during the casting and subsequent heat treatment processes. All heats showed no sign of intermetallic phase per Method A, passed minimum Charpy impact energy requirements per Method B (> 40 ft-lbs {at} -40 C (-40 F)), and showed negligible weight loss per Method C (< 10 mdd). These results indicate that the solution annealing procedure used by foundries is adequate to produce a product free from intermetallic phases.« less

  8. New prior sampling methods for nested sampling - Development and testing

    NASA Astrophysics Data System (ADS)

    Stokes, Barrie; Tuyl, Frank; Hudson, Irene

    2017-06-01

    Nested Sampling is a powerful algorithm for fitting models to data in the Bayesian setting, introduced by Skilling [1]. The nested sampling algorithm proceeds by carrying out a series of compressive steps, involving successively nested iso-likelihood boundaries, starting with the full prior distribution of the problem parameters. The "central problem" of nested sampling is to draw at each step a sample from the prior distribution whose likelihood is greater than the current likelihood threshold, i.e., a sample falling inside the current likelihood-restricted region. For both flat and informative priors this ultimately requires uniform sampling restricted to the likelihood-restricted region. We present two new methods of carrying out this sampling step, and illustrate their use with the lighthouse problem [2], a bivariate likelihood used by Gregory [3] and a trivariate Gaussian mixture likelihood. All the algorithm development and testing reported here has been done with Mathematica® [4].

  9. 40 CFR 80.582 - What are the sampling and testing methods for the fuel marker?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... developed by a Voluntary Consensus-Based Standards Body, such as the American Society for Testing and... test method documentation, including a description of the technology and/or instrumentation that makes... this standard from the American Society for Testing and Materials, 100 Barr Harbor Dr., West...

  10. 40 CFR 80.582 - What are the sampling and testing methods for the fuel marker?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... developed by a Voluntary Consensus-Based Standards Body, such as the American Society for Testing and... test method documentation, including a description of the technology and/or instrumentation that makes... this standard from the American Society for Testing and Materials, 100 Barr Harbor Dr., West...

  11. Detecting and enumerating soil-transmitted helminth eggs in soil: New method development and results from field testing in Kenya and Bangladesh

    PubMed Central

    Kwong, Laura H.; Ercumen, Ayse; Negash, Makeda S.; Lovely, Amira J.; Njenga, Sammy M.; Boehm, Alexandria B.; Pickering, Amy J.; Nelson, Kara L.

    2017-01-01

    Globally, about 1.5 billion people are infected with at least one species of soil-transmitted helminth (STH). Soil is a critical environmental reservoir of STH, yet there is no standard method for detecting STH eggs in soil. We developed a field method for enumerating STH eggs in soil and tested the method in Bangladesh and Kenya. The US Environmental Protection Agency (EPA) method for enumerating Ascaris eggs in biosolids was modified through a series of recovery efficiency experiments; we seeded soil samples with a known number of Ascaris suum eggs and assessed the effect of protocol modifications on egg recovery. We found the use of 1% 7X as a surfactant compared to 0.1% Tween 80 significantly improved recovery efficiency (two-sided t-test, t = 5.03, p = 0.007) while other protocol modifications—including different agitation and flotation methods—did not have a significant impact. Soil texture affected the egg recovery efficiency; sandy samples resulted in higher recovery compared to loamy samples processed using the same method (two-sided t-test, t = 2.56, p = 0.083). We documented a recovery efficiency of 73% for the final improved method using loamy soil in the lab. To field test the improved method, we processed soil samples from 100 households in Bangladesh and 100 households in Kenya from June to November 2015. The prevalence of any STH (Ascaris, Trichuris or hookworm) egg in soil was 78% in Bangladesh and 37% in Kenya. The median concentration of STH eggs in soil in positive samples was 0.59 eggs/g dry soil in Bangladesh and 0.15 eggs/g dry soil in Kenya. The prevalence of STH eggs in soil was significantly higher in Bangladesh than Kenya (chi-square, χ2 = 34.39, p < 0.001) as was the concentration (Mann-Whitney, z = 7.10, p < 0.001). This new method allows for detecting STH eggs in soil in low-resource settings and could be used for standardizing soil STH detection globally. PMID:28379956

  12. A comparison of the BAX system method to the U.S. Food and Drug Administration's Bacteriological Analytical Manual and International Organization for Standardization reference methods for the detection of Salmonella in a variety of soy ingredients.

    PubMed

    Belete, Tamrat; Crowley, Erin; Bird, Patrick; Gensic, Joseph; Wallace, F Morgan

    2014-10-01

    The performances of two DuPont BAX System PCR assays for detecting Salmonella on a variety of low-moisture soy ingredients were evaluated against the U. S. Food and Drug Administration's Bacteriological Analytical Manual (FDA BAM) method or the International Organization for Standardization (ISO) 6579 reference method. These evaluations were conducted as a single laboratory validation at an ISO 17025 accredited third-party laboratory. Validations were conducted on five soy ingredients: isolated soy protein (ISP), soy fiber, fluid soy lecithin, deoiled soy lecithin, and soy nuggets, using a paired-study design. The ISP was analyzed as both 25- and 375-g composite test portions, whereas all other sample matrices were analyzed as 375-g composite test portions. To evaluate 25-g test portions of ISP, the test material was inoculated using Salmonella enterica subsp. enterica serovar Mbandaka (Q Laboratories isolate 11031.1). Salmonella enterica subsp. enterica serovar Tennessee (Q Laboratories isolate 11031.3) was used for all other trials. For each trial of the method comparison, 25 samples were analyzed for each matrix: 5 uninoculated controls and 20 samples inoculated at low levels (0.2 to 2 CFU per test portion) that were targeted to achieve fractionally positive results (25 to 75%). Using McNemar's chi-square analysis, no significant difference at P ≥ 0.05 (χ(2) ≤ 3.84) was observed between the number of positives obtained by the BAX System and the reference methods for all five test matrices evaluated. These studies indicate that the BAX System PCR assays, in combination with the single buffered peptone water primary enrichment and subsequent brain heart infusion regrowth step, demonstrate equivalent sensitivity and robustness compared with the FDA BAM and ISO reference methods for both 25- and 375-g composite samples. Moreover, there was no observed reduction of sensitivity in the larger 375-g composite samples for all five matrices.

  13. Analysis of arson fire debris by low temperature dynamic headspace adsorption porous layer open tubular columns.

    PubMed

    Nichols, Jessica E; Harries, Megan E; Lovestead, Tara M; Bruno, Thomas J

    2014-03-21

    In this paper we present results of the application of PLOT-cryoadsorption (PLOT-cryo) to the analysis of ignitable liquids in fire debris. We tested ignitable liquids, broadly divided into fuels and solvents (although the majority of the results presented here were obtained with gasoline and diesel fuel) on three substrates: Douglas fir, oak plywood and Nylon carpet. We determined that PLOT-cryo allows the analyst to distinguish all of the ignitable liquids tested by use of a very rapid sampling protocol, and performs better (more recovered components, higher efficiency, lower elution solvent volumes) than a conventional purge and trap method. We also tested the effect of latency (the time period between applying the ignitable liquid and ignition), and we tested a variety of sampling times and a variety of PLOT capillary lengths. Reliable results can be obtained with sampling time periods as short as 3min, and on PLOT capillaries as short as 20cm. The variability of separate samples was also assessed, a study made possible by the high throughput nature of the PLOT-cryo method. We also determined that the method performs better than the conventional carbon strip method that is commonly used in fire debris analysis. Published by Elsevier B.V.

  14. Assessment of Different Sampling Methods for Measuring and Representing Macular Cone Density Using Flood-Illuminated Adaptive Optics

    PubMed Central

    Feng, Shu; Gale, Michael J.; Fay, Jonathan D.; Faridi, Ambar; Titus, Hope E.; Garg, Anupam K.; Michaels, Keith V.; Erker, Laura R.; Peters, Dawn; Smith, Travis B.; Pennesi, Mark E.

    2015-01-01

    Purpose To describe a standardized flood-illuminated adaptive optics (AO) imaging protocol suitable for the clinical setting and to assess sampling methods for measuring cone density. Methods Cone density was calculated following three measurement protocols: 50 × 50-μm sampling window values every 0.5° along the horizontal and vertical meridians (fixed-interval method), the mean density of expanding 0.5°-wide arcuate areas in the nasal, temporal, superior, and inferior quadrants (arcuate mean method), and the peak cone density of a 50 × 50-μm sampling window within expanding arcuate areas near the meridian (peak density method). Repeated imaging was performed in nine subjects to determine intersession repeatability of cone density. Results Cone density montages could be created for 67 of the 74 subjects. Image quality was determined to be adequate for automated cone counting for 35 (52%) of the 67 subjects. We found that cone density varied with different sampling methods and regions tested. In the nasal and temporal quadrants, peak density most closely resembled histological data, whereas the arcuate mean and fixed-interval methods tended to underestimate the density compared with histological data. However, in the inferior and superior quadrants, arcuate mean and fixed-interval methods most closely matched histological data, whereas the peak density method overestimated cone density compared with histological data. Intersession repeatability testing showed that repeatability was greatest when sampling by arcuate mean and lowest when sampling by fixed interval. Conclusions We show that different methods of sampling can significantly affect cone density measurements. Therefore, care must be taken when interpreting cone density results, even in a normal population. PMID:26325414

  15. Comparing the NIOSH Method 5040 to a Diesel Particulate Matter Meter for Elemental Carbon

    NASA Astrophysics Data System (ADS)

    Ayers, David Matthew

    Introduction: The sampling of elemental carbon has been associated with monitoring exposures in the trucking and mining industries. Recently, in the field of engineered nanomaterials, single wall and muti-wall carbon nanotubes (MWCNTs) are being produced in ever increasing quantities. The only approved atmospheric sampling for multi-wall carbon nanotubes in NIOSH Method 5040. These results are accurate but can take up to 30 days for sample results to be received. Objectives: Compare the results of elemental carbon sampling from the NIOSH Method 5040 to a Diesel Particulate Matter (DPM) Meter. Methods: MWCNTs were transferred and weighed between several trays placed on a scale. The NIOSH Method 5040 and DPM sampling train was hung 6 inches above the receiving tray. The transferring and weighing of the MWCNTs created an aerosol containing elemental carbon. Twenty-one total samples using both meters type were collected. Results: The assumptions for a Two-Way ANOVA were violated therefore, Mann-Whitney U Tests and a Kruskal-Wallis Test were performed. The hypotheses for both research questions were rejected. There was a significant difference in the EC concentrations obtained by the NIOSH Method 5040 and the DPM meter. There were also significant differences in elemental carbon level concentrations when sampled using a DPM meter versus a sampling pump based upon the three concentration levels (low, medium and high). Conclusions: The differences in the EC concentrations were statistically significant therefore, the two methods (NIOSH Method 5040 and DPM) are not the same. The NIOSH Method 5040 should continue to be the only authorized method of establishing an EC concentration for MWCNTs until a MWCNT specific method or an instantaneous meter is invented.

  16. Improved sensitivity of the urine CAA lateral-flow assay for diagnosing active Schistosoma infections by using larger sample volumes.

    PubMed

    Corstjens, Paul L A M; Nyakundi, Ruth K; de Dood, Claudia J; Kariuki, Thomas M; Ochola, Elizabeth A; Karanja, Diana M S; Mwinzi, Pauline N M; van Dam, Govert J

    2015-04-22

    Accurate determination of Schistosoma infection rates in low endemic regions to examine progress towards interruption of transmission and elimination requires highly sensitive diagnostic tools. An existing lateral flow (LF) based test demonstrating ongoing infections through detection of worm circulating anodic antigen (CAA), was improved for sensitivity through implementation of a protocol allowing increased sample input. Urine is the preferred sample as collection is non-invasive and sample volume is generally not a restriction. Centrifugal filtration devices provided a method to concentrate supernatant of urine samples extracted with trichloroacetic acid (TCA). For field trials a practical sample volume of 2 mL urine allowed detection of CAA down to 0.3 pg/mL. The method was evaluated on a set of urine samples (n = 113) from an S. mansoni endemic region (Kisumu, Kenya) and compared to stool microscopy (Kato Katz, KK). In this analysis true positivity was defined as a sample with either a positive KK or UCAA test. Implementation of the concentration method increased clinical sensitivity (Sn) from 44 to 98% when moving from the standard 10 μL (UCAA10 assay) to 2000 μL (UCAA2000 assay) urine sample input. Sn for KK varied between 23 and 35% for a duplicate KK (single stool, two slides) to 52% for a six-fold KK (three consecutive day stools, two slides). The UCAA2000 assay indicated 47 positive samples with CAA concentration above 0.3 pg/mL. The six-fold KK detected 25 egg positives; 1 sample with 2 eggs detected in the 6-fold KK was not identified with the UCAA2000 assay. Larger sample input increased Sn of the UCAA assay to a level indicating 'true' infection. Only a single 2 mL urine sample is needed, but analysing larger sample volumes could still increase test accuracy. The UCAA2000 test is an appropriate candidate for accurate identification of all infected individuals in low-endemic regions. Assay materials do not require refrigeration and collected urine samples may be stored and transported to central test laboratories without the need to be frozen.

  17. ETV TEST OF PCDD/F EMISSIONS MONITORING SYSTEMS

    EPA Science Inventory

    Four polychlorinated dibenzodioxin and furan (PCDD/F) emission monitors were tested under the EPA Environmental Technology and Verification (ETV) program. Two long-term sampling devices, the DioxinMonitoringSystem and Adsorption Method for Sampling Dioxins and Furans, and two sem...

  18. ANALYTICAL METHOD DEVELOPMENTS TO SUPPORT PARTITIONING INTERWELL TRACER TESTING

    EPA Science Inventory

    Partitioning Interwell Tracer Testing (PITT) uses alcohol tracer compounds in estimating subsurface contamination from non-polar pollutants. PITT uses the analysis of water samples for various alcohols as part of the overall measurement process. The water samples may contain many...

  19. Testing common stream sampling methods for broad-scale, long-term monitoring

    Treesearch

    Eric K. Archer; Brett B. Roper; Richard C. Henderson; Nick Bouwes; S. Chad Mellison; Jeffrey L. Kershner

    2004-01-01

    We evaluated sampling variability of stream habitat sampling methods used by the USDA Forest Service and the USDI Bureau of Land Management monitoring program for the upper Columbia River Basin. Three separate studies were conducted to describe the variability of individual measurement techniques, variability between crews, and temporal variation throughout the summer...

  20. Acoustic emission strand burning technique for motor burning rate prediction

    NASA Technical Reports Server (NTRS)

    Christensen, W. N.

    1978-01-01

    An acoustic emission (AE) method is being used to measure the burning rate of solid propellant strands. This method has a precision of 0.5% and excellent burning rate correlation with both subscale and large rocket motors. The AE procedure burns the sample under water and measures the burning rate from the acoustic output. The acoustic signal provides a continuous readout during testing, which allows complete data analysis rather than the start-stop clockwires used by the conventional method. The AE method helps eliminate such problems as inhibiting the sample, pressure increase and temperature rise, during testing.

  1. Fast Ordered Sampling of DNA Sequence Variants.

    PubMed

    Greenberg, Anthony J

    2018-05-04

    Explosive growth in the amount of genomic data is matched by increasing power of consumer-grade computers. Even applications that require powerful servers can be quickly tested on desktop or laptop machines if we can generate representative samples from large data sets. I describe a fast and memory-efficient implementation of an on-line sampling method developed for tape drives 30 years ago. Focusing on genotype files, I test the performance of this technique on modern solid-state and spinning hard drives, and show that it performs well compared to a simple sampling scheme. I illustrate its utility by developing a method to quickly estimate genome-wide patterns of linkage disequilibrium (LD) decay with distance. I provide open-source software that samples loci from several variant format files, a separate program that performs LD decay estimates, and a C++ library that lets developers incorporate these methods into their own projects. Copyright © 2018 Greenberg.

  2. Data Analysis Recipes: Using Markov Chain Monte Carlo

    NASA Astrophysics Data System (ADS)

    Hogg, David W.; Foreman-Mackey, Daniel

    2018-05-01

    Markov Chain Monte Carlo (MCMC) methods for sampling probability density functions (combined with abundant computational resources) have transformed the sciences, especially in performing probabilistic inferences, or fitting models to data. In this primarily pedagogical contribution, we give a brief overview of the most basic MCMC method and some practical advice for the use of MCMC in real inference problems. We give advice on method choice, tuning for performance, methods for initialization, tests of convergence, troubleshooting, and use of the chain output to produce or report parameter estimates with associated uncertainties. We argue that autocorrelation time is the most important test for convergence, as it directly connects to the uncertainty on the sampling estimate of any quantity of interest. We emphasize that sampling is a method for doing integrals; this guides our thinking about how MCMC output is best used. .

  3. Pre-analytical effects of blood sampling and handling in quantitative immunoassays for rheumatoid arthritis.

    PubMed

    Zhao, Xiaoyan; Qureshi, Ferhan; Eastman, P Scott; Manning, William C; Alexander, Claire; Robinson, William H; Hesterberg, Lyndal K

    2012-04-30

    Variability in pre-analytical blood sampling and handling can significantly impact results obtained in quantitative immunoassays. Understanding the impact of these variables is critical for accurate quantification and validation of biomarker measurements. Particularly, in the design and execution of large clinical trials, even small differences in sample processing and handling can have dramatic effects in analytical reliability, results interpretation, trial management and outcome. The effects of two common blood sampling methods (serum vs. plasma) and two widely-used serum handling methods (on the clot with ambient temperature shipping, "traditional", vs. centrifuged with cold chain shipping, "protocol") on protein and autoantibody concentrations were examined. Matched serum and plasma samples were collected from 32 rheumatoid arthritis (RA) patients representing a wide range of disease activity status. Additionally, a set of matched serum samples with two sample handling methods was collected. One tube was processed per manufacturer's instructions and shipped overnight on cold packs (protocol). The matched tube, without prior centrifugation, was simultaneously shipped overnight at ambient temperatures (traditional). Upon delivery, the traditional tube was centrifuged. All samples were subsequently aliquoted and frozen prior to analysis of protein and autoantibody biomarkers. Median correlation between paired serum and plasma across all autoantibody assays was 0.99 (0.98-1.00) with a median % difference of -3.3 (-7.5 to 6.0). In contrast, observed protein biomarker concentrations were significantly affected by sample types, with median correlation of 0.99 (0.33-1.00) and a median % difference of -10 (-55 to 23). When the two serum collection/handling methods were compared, the median correlation between paired samples for autoantibodies was 0.99 (0.91-1.00) with a median difference of 4%. In contrast, significant increases were observed in protein biomarker concentrations among certain biomarkers in samples processed with the 'traditional' method. Autoantibody quantification appears robust to both sample type (plasma vs. serum) and pre-analytical sample collection/handling methods (protocol vs. traditional). In contrast, for non-antibody protein biomarker concentrations, sample type had a significant impact; plasma samples generally exhibit decreased protein biomarker concentrations relative to serum. Similarly, sample handling significantly impacted the variability of protein biomarker concentrations. When biomarker concentrations are combined algorithmically into a single test score such as a multi-biomarker disease activity test for rheumatoid arthritis (MBDA), changes in protein biomarker concentrations may result in a bias of the score. These results illustrate the importance of characterizing pre-analytical methodology, sample type, sample processing and handling procedures for clinical testing in order to ensure test accuracy. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Waste Analysis Plan and Waste Characterization Survey, Barksdale AFB, Louisiana

    DTIC Science & Technology

    1991-03-01

    review to assess if analysis is needed, any analyses that are to be provided by generators, and methods to be used to meet specific waste analysis ...sampling method , sampling frequency, parameters of analysis , SW 846 test methods , Department of Transportation (DOT) shipping name and hazard class...S.e.iceA w/Atchs 2. HQ SAC/DEV Ltr, 28 Sep 90 19 119 APPENDIX B Waste Analysis Plan Rationale 21 APPENDIX B 1. SAMPLING METHOD RATIONALE: Composite Liquid

  5. LEAK AND GAS PERMEABILITY TESTING DURING SOIL-GAS SAMPLING AT HAL'S CHEVRON LUST SITE IN GREEN RIVER, UTAH

    EPA Science Inventory

    The results of gas permeability and leak testing during active soil-gas sampling at Hal’s Chevron LUST Site in Green River, Utah are presented. This study was conducted to support development of a passive soil-gas sampling method. Gas mixtures containing helium and methane were...

  6. 16 CFR 1500.44 - Method for determining extremely flammable and flammable solids.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    .... Measure the dimensions of the sample and support it by means of metal ringstands, clamps, rings, or other... be ventilated and cleared after each test. The temperature of the sample at the time of testing shall... or until the sample ignites, whichever is less. Remove the candle. By means of a stopwatch, determine...

  7. Modified sugar adulteration test applied to New Zealand honey.

    PubMed

    Frew, Russell; McComb, Kiri; Croudis, Linda; Clark, Dianne; Van Hale, Robert

    2013-12-15

    The carbon isotope method (AOAC 998.12) compares the bulk honey carbon isotope value with that of the extracted protein; a difference greater than 1‰ suggesting that the protein and the bulk carbohydrate have different origins. New Zealand Manuka honey is a high value product and often fails this test. It has been suggested such failures are due to the pollen in the Manuka honey and an adaptation of the method to remove pollen prior to testing has been proposed. Here we test 64 authentic honey samples collected directly from the hives and find that a large proportion (37%) of Manuka honeys fail the test. Of these 60% still fail the adapted method. These honey samples were collected and processed under stringent conditions and have not been adulterated post-harvest. More work is required to ascertain the cause of these test failures. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Microwave absorption properties of gold nanoparticle doped polymers

    NASA Astrophysics Data System (ADS)

    Jiang, C.; Ouattara, L.; Ingrosso, C.; Curri, M. L.; Krozer, V.; Boisen, A.; Jakobsen, M. H.; Johansen, T. K.

    2011-03-01

    This paper presents a method for characterizing microwave absorption properties of gold nanoparticle doped polymers. The method is based on on-wafer measurements at the frequencies from 0.5 GHz to 20 GHz. The on-wafer measurement method makes it possible to characterize electromagnetic (EM) property of small volume samples. The epoxy based SU8 polymer and SU8 doped with gold nanoparticles are chosen as the samples under test. Two types of microwave test devices are designed for exciting the samples through electrical coupling and magnetic coupling, respectively. Measurement results demonstrate that the nanocomposites absorb a certain amount of microwave energy due to gold nanoparticles. Higher nanoparticle concentration results in more significant absorption effect.

  9. A preliminary test method for masonry heater particulate matter and carbon monoxide emissions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stern, C.H.; Jaasma, D.R.; Shelton, J.W.

    1991-08-01

    A test method for determining carbon monoxide (CO) and particulate matter (PM) emissions from masonry heaters is described and results of tests on two masonry heaters are presented. The method specifies fueling protocol and laboratory measurement procedures for determination of both emission factors (g/kg) and rates (g/hr). The fuel load size and fueling intervals are dependent upon the firebox volume of the masonry heater. The test method starts with a room temperature masonry heater and involves five firings to achieve burn rates in two ranges, where the burn rate is defined as the dry mass of the fuel load dividedmore » by the time between loadings. Emission samples are extracted from a dilution tunnel with a set flow rate and configuration. Particulate matter sampling is similar to US EPA Method 5G for woodstoves, and Co concentration is measured by a nondispersive infrared (NDIR) gas analyzer. The emissions results for each firing are weighted according to EPA Method 28 to obtain the overall emission totals for the test.« less

  10. Evaluation of 3 dental unit waterline contamination testing methods

    PubMed Central

    Porteous, Nuala; Sun, Yuyu; Schoolfield, John

    2015-01-01

    Previous studies have found inconsistent results from testing methods used to measure heterotrophic plate count (HPC) bacteria in dental unit waterline (DUWL) samples. This study used 63 samples to compare the results obtained from an in-office chairside method and 2 currently used commercial laboratory HPC methods (Standard Methods 9215C and 9215E). The results suggest that the Standard Method 9215E is not suitable for application to DUWL quality monitoring, due to the detection of limited numbers of heterotrophic organisms at the required 35°C incubation temperature. The results also confirm that while the in-office chairside method is useful for DUWL quality monitoring, the Standard Method 9215C provided the most accurate results. PMID:25574718

  11. ISO 15859 Propellant and Fluid Specifications: A Review and Comparison with Military and NASA Specifications

    NASA Technical Reports Server (NTRS)

    Greene, Ben; McClure, Mark B.; Baker, David L.

    2006-01-01

    This work presents an overview of the International Organization for Standardization (ISO) 15859 International Standard for Space Systems Fluid Characteristics, Sampling and Test Methods Parts 1 through 13 issued in June 2004. These standards establish requirements for fluid characteristics, sampling, and test methods for 13 fluids of concern to the propellant community and propellant characterization laboratories: oxygen, hydrogen, nitrogen, helium, nitrogen tetroxide, monomethylhydrazine, hydrazine, kerosene, argon, water, ammonia, carbon dioxide, and breathing air. A comparison of the fluid characteristics, sampling, and test methods required by the ISO standards to the current military and NASA specifications, which are in use at NASA facilities and elsewhere, is presented. Many ISO standards composition limits and other content agree with those found in the applicable parts of NASA SE-S-0073, NASA SSP 30573, military performance standards and details, and Compressed Gas Association (CGA) commodity specifications. The status of a current project managed at NASA Johnson Space Center White Sands Test Facility (WSTF) to rewrite these documents is discussed.

  12. Computational fragment-based screening using RosettaLigand: the SAMPL3 challenge

    NASA Astrophysics Data System (ADS)

    Kumar, Ashutosh; Zhang, Kam Y. J.

    2012-05-01

    SAMPL3 fragment based virtual screening challenge provides a valuable opportunity for researchers to test their programs, methods and screening protocols in a blind testing environment. We participated in SAMPL3 challenge and evaluated our virtual fragment screening protocol, which involves RosettaLigand as the core component by screening a 500 fragments Maybridge library against bovine pancreatic trypsin. Our study reaffirmed that the real test for any virtual screening approach would be in a blind testing environment. The analyses presented in this paper also showed that virtual screening performance can be improved, if a set of known active compounds is available and parameters and methods that yield better enrichment are selected. Our study also highlighted that to achieve accurate orientation and conformation of ligands within a binding site, selecting an appropriate method to calculate partial charges is important. Another finding is that using multiple receptor ensembles in docking does not always yield better enrichment than individual receptors. On the basis of our results and retrospective analyses from SAMPL3 fragment screening challenge we anticipate that chances of success in a fragment screening process could be increased significantly with careful selection of receptor structures, protein flexibility, sufficient conformational sampling within binding pocket and accurate assignment of ligand and protein partial charges.

  13. Multiparametric comparison of chromogenic-based culture methods used to assess the microbiological quality of drinking water and the mFC method combined with a molecular confirmation procedure.

    PubMed

    Maheux, Andrée F; Dion-Dupont, Vanessa; Bisson, Marc-Antoine; Bouchard, Sébastien; Jubinville, Éric; Nkuranga, Martine; Rodrigue, Lynda; Bergeron, Michel G; Rodriguez, Manuel J

    2015-03-01

    MI agar and Colilert(®), as well as mFC agar combined with an Escherichia coli-specific molecular assay (mFC + E. coli rtPCR), were compared in terms of their sensitivity, ease of use, time to result and affordability. The three methods yielded a positive E. coli signal for 11.5, 10.8, and 11.5% of the 968 well water samples tested, respectively. One hundred and thirty-six (136) samples gave blue colonies on mFC agar and required confirmation. E. coli-specific rtPCR showed false-positive results in 23.5% (32/136) of cases. In terms of ease of use, Colilert was the simplest method to use while the MI method provided ease of use comparable to all membrane filtration methods. However, the mFC + E. coli rtPCR assay required highly trained employees for confirmation purposes. In terms of affordability, and considering contamination rate of well water samples tested, the Colilert method and the mFC + E. coli rtPCR assay were at least five times more costly than the MI agar method. Overall, compared with the other two methods tested, the MI agar method offers the most advantages to assess drinking water quality.

  14. Evaluation of the clinical sensitivity for the quantification of human immunodeficiency virus type 1 RNA in plasma: Comparison of the new COBAS TaqMan HIV-1 with three current HIV-RNA assays--LCx HIV RNA quantitative, VERSANT HIV-1 RNA 3.0 (bDNA) and COBAS AMPLICOR HIV-1 Monitor v1.5.

    PubMed

    Katsoulidou, Antigoni; Petrodaskalaki, Maria; Sypsa, Vana; Papachristou, Eleni; Anastassopoulou, Cleo G; Gargalianos, Panagiotis; Karafoulidou, Anastasia; Lazanas, Marios; Kordossis, Theodoros; Andoniadou, Anastasia; Hatzakis, Angelos

    2006-02-01

    The COBAS TaqMan HIV-1 test (Roche Diagnostics) was compared with the LCx HIV RNA quantitative assay (Abbott Laboratories), the Versant HIV-1 RNA 3.0 (bDNA) assay (Bayer) and the COBAS Amplicor HIV-1 Monitor v1.5 test (Roche Diagnostics), using plasma samples of various viral load levels from HIV-1-infected individuals. In the comparison of TaqMan with LCx, TaqMan identified as positive 77.5% of the 240 samples versus 72.1% identified by LCx assay, while their overall agreement was 94.6% and the quantitative results of samples that were positive by both methods were strongly correlated (r=0.91). Similarly, in the comparison of TaqMan with bDNA 3.0, both methods identified 76.3% of the 177 samples as positive, while their overall agreement was 95.5% and the quantitative results of samples that were positive by both methods were strongly correlated (r=0.95). Finally, in the comparison of TaqMan with Monitor v1.5, TaqMan identified 79.5% of the 156 samples as positive versus 80.1% identified by Monitor v1.5, while their overall agreement was 95.5% and the quantitative results of samples that were positive by both methods were strongly correlated (r=0.96). In conclusion, the new COBAS TaqMan HIV-1 test showed excellent agreement with other widely used commercially available tests for the quantitation of HIV-1 viral load.

  15. Brain Jogging Training to Improve Motivation and Learning Result of Tennis Skills

    NASA Astrophysics Data System (ADS)

    Tafaqur, M.; Komarudin; Mulyana; Saputra, M. Y.

    2017-03-01

    This research is aimed to determine the effect of brain jogging towards improvement of motivation and learning result of tennis skills. The method used in this research is experimental method. The population of this research is 15 tennis athletes of Core Siliwangi Bandung Tennis Club. The sampling technique used in this research is purposive sampling technique. Sample of this research is the 10 tennis athletes of Core Siliwangi Bandung Tennis Club. Design used for this research is pretest-posttest group design. Data analysis technique used in this research is by doing Instrument T-test to measure motivation using The Sport Motivation Scale questionnaire (SMS-28) and Instrument to measure learning result of tennis skill by using tennis skills test, which include: (1) forehand test, (2) backhand test, and (3) service placement test. The result of this research showed that brain jogging significantly impact the improvement of motivation and learning result of tennis skills.

  16. Quality-assurance procedures: Method 5G determination of particulate emissions from wood heaters from a dilution tunnel sampling location

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ward, T.E.; Hartman, M.W.; Olin, R.C.

    1989-06-01

    Quality-assurance procedures are contained in this comprehensive document intended to be used as an aid for wood-heater manufacturers and testing laboratories in performing particulate matter sampling of wood heaters according to EPA protocol, Method 5G. These procedures may be used in research and development, and as an aid in auditing and certification testing. A detailed, step-by-step quality assurance guide is provided to aid in the procurement and assembly of testing apparatus, to clearly describe the procedures, and to facilitate data collection and reporting. Suggested data sheets are supplied that can be used as an aid for both recordkeeping and certificationmore » applications. Throughout the document, activity matrices are provided to serve as a summary reference. Checklists are also supplied that can be used by testing personnel. Finally, for the purposes of ensuring data quality, procedures are outlined for apparatus operation, maintenance, and traceability. These procedures combined with the detailed description of the sampling and analysis protocol will help ensure the accuracy and reliability of Method 5G emission-testing results.« less

  17. Idiographic duo-trio tests using a constant-reference based on preference of each consumer: Sample presentation sequence in difference test can be customized for individual consumers to reduce error.

    PubMed

    Kim, Min-A; Sim, Hye-Min; Lee, Hye-Seong

    2016-11-01

    As reformulations and processing changes are increasingly needed in the food industry to produce healthier, more sustainable, and cost effective products while maintaining superior quality, reliable measurements of consumers' sensory perception and discrimination are becoming more critical. Consumer discrimination methods using a preferred-reference duo-trio test design have been shown to be effective in improving the discrimination performance by customizing sample presentation sequences. However, this design can add complexity to the discrimination task for some consumers, resulting in more errors in sensory discrimination. The objective of the present study was to investigate the effects of different types of test instructions using the preference-reference duo-trio test design where a paired-preference test is followed by 6 repeated preferred-reference duo-trio tests, in comparison to the analytical method using the balanced-reference duo-trio. Analyses of d' estimates (product-related measure) and probabilistic sensory discriminators in momentary numbers of subjects showing statistical significance (subject-related measure) revealed that only preferred-reference duo-trio test using affective reference-framing, either by providing no information about the reference or information on a previously preferred sample, improved the sensory discrimination more than the analytical method. No decrease in discrimination performance was observed with any type of instruction, confirming that consumers could handle the test methods. These results suggest that when repeated tests are feasible, using the affective discrimination method would be operationally more efficient as well as ecologically more reliable for measuring consumers' sensory discrimination ability. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. A comparison of confidence/credible interval methods for the area under the ROC curve for continuous diagnostic tests with small sample size.

    PubMed

    Feng, Dai; Cortese, Giuliana; Baumgartner, Richard

    2017-12-01

    The receiver operating characteristic (ROC) curve is frequently used as a measure of accuracy of continuous markers in diagnostic tests. The area under the ROC curve (AUC) is arguably the most widely used summary index for the ROC curve. Although the small sample size scenario is common in medical tests, a comprehensive study of small sample size properties of various methods for the construction of the confidence/credible interval (CI) for the AUC has been by and large missing in the literature. In this paper, we describe and compare 29 non-parametric and parametric methods for the construction of the CI for the AUC when the number of available observations is small. The methods considered include not only those that have been widely adopted, but also those that have been less frequently mentioned or, to our knowledge, never applied to the AUC context. To compare different methods, we carried out a simulation study with data generated from binormal models with equal and unequal variances and from exponential models with various parameters and with equal and unequal small sample sizes. We found that the larger the true AUC value and the smaller the sample size, the larger the discrepancy among the results of different approaches. When the model is correctly specified, the parametric approaches tend to outperform the non-parametric ones. Moreover, in the non-parametric domain, we found that a method based on the Mann-Whitney statistic is in general superior to the others. We further elucidate potential issues and provide possible solutions to along with general guidance on the CI construction for the AUC when the sample size is small. Finally, we illustrate the utility of different methods through real life examples.

  19. Detection of antileishmanial antibodies in blood sampled from blood bank donors in Istanbul.

    PubMed

    Ates, Sezen Canim; Bagirova, Malahat; Allahverdiyev, Adil M; Baydar, Serap Yesilkir; Koc, Rabia Cakir; Elcicek, Serhat; Abamor, Emrah Sefik; Oztel, Olga Nehir

    2012-06-01

    According to the WHO, only 5-20% of the total cases of leishmaniasis are symptomatic leishmaniasis; the other cases are identified as asymptomatic leishmaniasis. In recent studies, it has been demonstrated that donor blood plays an important role in the epidemiology of asymptomatic leishmaniasis. However, the number of the studies on this subject is still insufficient. Additionally, donor blood samples obtained from Istanbul, which is the biggest metropolitan area in Turkey, have not been investigated with regard to Leishmania. Moreover, there is no information about the sensitivity of noninvasive serological methods that are used in the detection of leishmaniasis donor blood samples. Accordingly, this study aimed to investigate the presence of antileishmanial antibodies in blood samples obtained from blood bank donors in Istanbul, by using different serologic methods, and to determine the most sensitive detection method. Blood samples were taken from 188 healthy blood bank donors to the Capa Turkish Red Crescent Blood Bank (Istanbul, Turkey), and the presence of antileishmanial antibodies was measured by indirect immunofluorescent antibody test (IFAT), ELISA, immunochromatographic dipstick rapid test, and western blot (WB). Antileishmanial antibodies were determined in 12 out of 188 samples by IFAT (6.4%), and six out of these 12 donors were found to be positive at diagnostic titer 1:128 (3.2%). One hundred and eighty eight samples were investigated by ELISA and one (0.5%) of them gave a positive result. None of 188 samples provided a positive result by immunochromatographic test. WB applied to the 12 seroreactive donors showed that three out of 12 donors were positive. In this study, the presence of antileishmanial antibodies in blood samples of blood bank donors from Istanbul has been demonstrated by using feasible and low-cost serological methods. Additionally, in comparison with other simple and low-cost detection methods, WB was used for confirmation. IFAT has a higher sensitivity and therefore may be preferred as a prescreening method in endemic or nonendemic areas.

  20. How to test validity in orthodontic research: a mixed dentition analysis example.

    PubMed

    Donatelli, Richard E; Lee, Shin-Jae

    2015-02-01

    The data used to test the validity of a prediction method should be different from the data used to generate the prediction model. In this study, we explored whether an independent data set is mandatory for testing the validity of a new prediction method and how validity can be tested without independent new data. Several validation methods were compared in an example using the data from a mixed dentition analysis with a regression model. The validation errors of real mixed dentition analysis data and simulation data were analyzed for increasingly large data sets. The validation results of both the real and the simulation studies demonstrated that the leave-1-out cross-validation method had the smallest errors. The largest errors occurred in the traditional simple validation method. The differences between the validation methods diminished as the sample size increased. The leave-1-out cross-validation method seems to be an optimal validation method for improving the prediction accuracy in a data set with limited sample sizes. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  1. Suitability of the line intersect method for sampling hardwood logging residues

    Treesearch

    A. Jeff Martin

    1976-01-01

    The line intersect method of sampling logging residues was tested in Appalachian hardwoods and was found to provide unbiased estimates of the volume of residue in cubic feet per acre. Thirty-two chains of sample line were established on each of sixteen 1-acre plots on cutover areas in a variety of conditions. Estimates from these samples were then compared to actual...

  2. Field and laboratory arsenic speciation methods and their application to natural-water analysis

    USGS Publications Warehouse

    Bednar, A.J.; Garbarino, J.R.; Burkhardt, M.R.; Ranville, J.F.; Wildeman, T.R.

    2004-01-01

    The toxic and carcinogenic properties of inorganic and organic arsenic species make their determination in natural water vitally important. Determination of individual inorganic and organic arsenic species is critical because the toxicology, mobility, and adsorptivity vary substantially. Several methods for the speciation of arsenic in groundwater, surface-water, and acid mine drainage sample matrices using field and laboratory techniques are presented. The methods provide quantitative determination of arsenite [As(III)], arsenate [As(V)], monomethylarsonate (MMA), dimethylarsinate (DMA), and roxarsone in 2-8min at detection limits of less than 1??g arsenic per liter (??g AsL-1). All the methods use anion exchange chromatography to separate the arsenic species and inductively coupled plasma-mass spectrometry as an arsenic-specific detector. Different methods were needed because some sample matrices did not have all arsenic species present or were incompatible with particular high-performance liquid chromatography (HPLC) mobile phases. The bias and variability of the methods were evaluated using total arsenic, As(III), As(V), DMA, and MMA results from more than 100 surface-water, groundwater, and acid mine drainage samples, and reference materials. Concentrations in test samples were as much as 13,000??g AsL-1 for As(III) and 3700??g AsL-1 for As(V). Methylated arsenic species were less than 100??g AsL-1 and were found only in certain surface-water samples, and roxarsone was not detected in any of the water samples tested. The distribution of inorganic arsenic species in the test samples ranged from 0% to 90% As(III). Laboratory-speciation method variability for As(III), As(V), MMA, and DMA in reagent water at 0.5??g AsL-1 was 8-13% (n=7). Field-speciation method variability for As(III) and As(V) at 1??g AsL-1 in reagent water was 3-4% (n=3). ?? 2003 Elsevier Ltd. All rights reserved.

  3. Comparison of a gel microcolumn assay with the conventional tube test for red blood cell alloantibody titration.

    PubMed

    Finck, Rachel; Lui-Deguzman, Carrie; Teng, Shih-Mao; Davis, Rebecca; Yuan, Shan

    2013-04-01

    Titration is a semiquantitative method used to estimate red blood cell (RBC) alloantibody reactivity. The conventional tube test (CTT) technique is the traditional method for performing titration studies. The gel microcolumn assay (GMA) is also a sensitive method to detect RBC alloantibodies. The aim of this study was to compare a GMA with the CTT technique in the performance of Rh and K alloantibody titration. Patient serum samples that contained an RBC alloantibody with a singular specificity were identified by routine blood bank workflow. Parallel titration studies were performed on these samples by both the CTT method and a GMA (ID-Micro Typing System anti-IgG gel card, Micro Typing Systems, Inc., an Ortho-Clinical Diagnostics Company). Forty-eight samples were included, including 11 anti-D, five anti-c, 13 anti-E, one anti-C, three anti-e, and 15 anti-K. Overall, the two methods generated identical results in 21 of 48 samples. For 42 samples (87.5%) the two methods generated results that were within one serial dilution, and for the remaining six samples, results were within two dilutions. GMA systems may perform comparably to the CTT in titrating alloantibodies to Rh and Kell antigens. © 2012 American Association of Blood Banks.

  4. Assessment of Different Sampling Methods for Measuring and Representing Macular Cone Density Using Flood-Illuminated Adaptive Optics.

    PubMed

    Feng, Shu; Gale, Michael J; Fay, Jonathan D; Faridi, Ambar; Titus, Hope E; Garg, Anupam K; Michaels, Keith V; Erker, Laura R; Peters, Dawn; Smith, Travis B; Pennesi, Mark E

    2015-09-01

    To describe a standardized flood-illuminated adaptive optics (AO) imaging protocol suitable for the clinical setting and to assess sampling methods for measuring cone density. Cone density was calculated following three measurement protocols: 50 × 50-μm sampling window values every 0.5° along the horizontal and vertical meridians (fixed-interval method), the mean density of expanding 0.5°-wide arcuate areas in the nasal, temporal, superior, and inferior quadrants (arcuate mean method), and the peak cone density of a 50 × 50-μm sampling window within expanding arcuate areas near the meridian (peak density method). Repeated imaging was performed in nine subjects to determine intersession repeatability of cone density. Cone density montages could be created for 67 of the 74 subjects. Image quality was determined to be adequate for automated cone counting for 35 (52%) of the 67 subjects. We found that cone density varied with different sampling methods and regions tested. In the nasal and temporal quadrants, peak density most closely resembled histological data, whereas the arcuate mean and fixed-interval methods tended to underestimate the density compared with histological data. However, in the inferior and superior quadrants, arcuate mean and fixed-interval methods most closely matched histological data, whereas the peak density method overestimated cone density compared with histological data. Intersession repeatability testing showed that repeatability was greatest when sampling by arcuate mean and lowest when sampling by fixed interval. We show that different methods of sampling can significantly affect cone density measurements. Therefore, care must be taken when interpreting cone density results, even in a normal population.

  5. Woodstove smoke and CO emissions: comparison of reference methods with the VIP sampler.

    PubMed

    Jaasma, D R; Champion, M C; Shelton, J W

    1990-06-01

    A new field sampler has been developed for measuring the particulate matter (PM) and carbon monoxide emissions of woodburning stoves. Particulate matter is determined by carbon balance and the workup of a sample train which is similar to a room-temperature EPA Method 5G train. A steel tank, initially evacuated, serves as the motive force for sampling and also accumulates a gas sample for post-test analysis of time-averaged stack CO and CO2 concentrations. Workup procedures can be completed within 72 hours of sampler retrieval. The system has been compared to reference methods in two laboratory test series involving six different woodburning appliances and two independent laboratories. The correlation of field sampler emission rates and reference method rates is strong.

  6. Woodstove smoke and CO emissions: Comparison of reference methods with the VIP sampler

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jaasma, D.R.; Champion, M.C.; Shelton, J.W.

    1990-06-01

    A new field sampler has been developed for measuring the particulate matter (PM) and carbon monoxide emissions of woodburning stoves. Particulate matter is determined by carbon balance and the workup of a sample train which is similar to a room-temperature EPA Method 5G train. A steel tank, initially evacuated, serves as the motive force for sampling and also accumulates a gas sample for post-test analysis of time-averaged stack CO and CO{sub 2} concentrations. Workup procedures can be completed within 72 hours of sampler retrieval. The system has been compared to reference methods in two laboratory test series involving six differentmore » woodburning appliances and two independent laboratories. The correlation of field sampler emission rates and reference method rates is strong.« less

  7. New method for detection of gastric cancer by hyperspectral imaging: a pilot study

    NASA Astrophysics Data System (ADS)

    Kiyotoki, Shu; Nishikawa, Jun; Okamoto, Takeshi; Hamabe, Kouichi; Saito, Mari; Goto, Atsushi; Fujita, Yusuke; Hamamoto, Yoshihiko; Takeuchi, Yusuke; Satori, Shin; Sakaida, Isao

    2013-02-01

    We developed a new, easy, and objective method to detect gastric cancer using hyperspectral imaging (HSI) technology combining spectroscopy and imaging A total of 16 gastroduodenal tumors removed by endoscopic resection or surgery from 14 patients at Yamaguchi University Hospital, Japan, were recorded using a hyperspectral camera (HSC) equipped with HSI technology Corrected spectral reflectance was obtained from 10 samples of normal mucosa and 10 samples of tumors for each case The 16 cases were divided into eight training cases (160 training samples) and eight test cases (160 test samples) We established a diagnostic algorithm with training samples and evaluated it with test samples Diagnostic capability of the algorithm for each tumor was validated, and enhancement of tumors by image processing using the HSC was evaluated The diagnostic algorithm used the 726-nm wavelength, with a cutoff point established from training samples The sensitivity, specificity, and accuracy rates of the algorithm's diagnostic capability in the test samples were 78.8% (63/80), 92.5% (74/80), and 85.6% (137/160), respectively Tumors in HSC images of 13 (81.3%) cases were well enhanced by image processing Differences in spectral reflectance between tumors and normal mucosa suggested that tumors can be clearly distinguished from background mucosa with HSI technology.

  8. Effect of Temperature on Ultrasonic Signal Propagation for Extra Virgin Olive Oil Adulteration

    NASA Astrophysics Data System (ADS)

    Alias, N. A.; Hamid, S. B. Abdul; Sophian, A.

    2017-11-01

    Fraud cases involving adulteration of extra virgin olive oil has become significant nowadays due to increasing in cost of supply and highlight given the benefit of extra virgin olive oil for human consumption. This paper presents the effects of temperature variation on spectral formed utilising pulse-echo technique of ultrasound signal. Several methods had been introduced to characterize the adulteration of extra virgin olive oil with other fluid sample such as mass chromatography, standard method by ASTM (density test, distillation test and evaporation test) and mass spectrometer. Pulse-echo method of ultrasound being a non-destructive method to be used to analyse the sound wave signal captured by oscilloscope. In this paper, a non-destructive technique utilizing ultrasound to characterize extra virgin olive oil adulteration level will be presented. It can be observed that frequency spectrum of sample with different ratio and variation temperature shows significant percentages different from 30% up to 70% according to temperature variation thus possible to be used for sample characterization.

  9. 40 CFR Appendix M to Part 51 - Recommended Test Methods for State Implementation Plans

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., and after the run with the cyclone removed. The cyclone is removed before the post-test leak-check to.... 4.1.4.3 Post-Test Leak-Check. A leak-check is required at the conclusion of each sampling run... disturbing the collected sample and use the following procedure to conduct a post-test leak-check. 4.1.4.3.1...

  10. 40 CFR Appendix M to Part 51 - Recommended Test Methods for State Implementation Plans

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., and after the run with the cyclone removed. The cyclone is removed before the post-test leak-check to.... 4.1.4.3 Post-Test Leak-Check. A leak-check is required at the conclusion of each sampling run... disturbing the collected sample and use the following procedure to conduct a post-test leak-check. 4.1.4.3.1...

  11. 40 CFR Appendix M to Part 51 - Recommended Test Methods for State Implementation Plans

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., and after the run with the cyclone removed. The cyclone is removed before the post-test leak-check to.... 4.1.4.3 Post-Test Leak-Check. A leak-check is required at the conclusion of each sampling run... disturbing the collected sample and use the following procedure to conduct a post-test leak-check. 4.1.4.3.1...

  12. 40 CFR Appendix M to Part 51 - Recommended Test Methods for State Implementation Plans

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., and after the run with the cyclone removed. The cyclone is removed before the post-test leak-check to.... 4.1.4.3 Post-Test Leak-Check. A leak-check is required at the conclusion of each sampling run... disturbing the collected sample and use the following procedure to conduct a post-test leak-check. 4.1.4.3.1...

  13. Using Set Covering with Item Sampling to Analyze the Infeasibility of Linear Programming Test Assembly Models

    ERIC Educational Resources Information Center

    Huitzing, Hiddo A.

    2004-01-01

    This article shows how set covering with item sampling (SCIS) methods can be used in the analysis and preanalysis of linear programming models for test assembly (LPTA). LPTA models can construct tests, fulfilling a set of constraints set by the test assembler. Sometimes, no solution to the LPTA model exists. The model is then said to be…

  14. ASBESTOS IN DRINKING WATER PERFORMANCE EVALUATION STUDIES

    EPA Science Inventory

    Performance evaluations of laboratories testing for asbestos in drinking water according to USEPA Test Method 100.1 or 100.2 are complicated by the difficulty of providing stable sample dispersions of asbestos in water. Reference samples of a graduated series of chrysotile asbes...

  15. ASBESTOS IN DRINKING WATER PERFORMANCE EVALUATION STUDIES

    EPA Science Inventory

    Performance evaluations of laboratories testing for asbestos in drinking water according to USEPA Test Method 100.1 or 100.2 are complicated by the difficulty of providing stable sample dispersions of asbestos in water. Reference samples of a graduated series of chrysotile asbest...

  16. Performance of asphalt mixture incorporating recycled waste

    NASA Astrophysics Data System (ADS)

    Hamid, Nor Baizura; Abdullah, Mohd Ezree; Sanik, Mohd Erwan; Mokhtar, Mardiha; Kaamin, Masiri; Raduan, Rasyidah; Ramli, Mohd Zakwan

    2017-12-01

    Nowadays, the amount of premix waste was increased every year, especially at the batching plants. Normally, the waste materials will be discarded without doing any innovative and effective research about those materials. This situation has become one of the global concerns due to the increasing number of premix waste produced every year. Therefore, the aim of this study is to evaluate the performance of hot mix asphalt (HMA) using premix waste on improving asphalt mixture fatigue behaviour. The method used in this study was Superpave mix design method. The sample conducted in this study were 0%, 10%, 20%, 30%, and 100% of premix waste respectively. For a binder test, the laboratory test conducted were penetration test, softening test and thin film oven test while for the performance test were resilient modulus test and indirect tensile fatigue test. From the laboratory test, the resilient modulus test was conducted with two different temperature which was 25°C and 40°C. The result from that test was 20% of premix waste had higher resilient modulus at that two different temperatures compared to another samples. From that test also shown that the sample at the lower temperature which was 25°C has higher resilient modulus compared to the temperature of 40°C. Indirect tensile fatigue test showed that the 30% of premix waste sample was suitable for the modified asphalt mixture with referring to the maximum deformation and strain for comparison control, 10%,20%, and 100% of premix waste samples. So, it can be concluded that premix waste inhibits great potential as road construction material and suitable for repeated traffic loading.

  17. Novel hybrid cryo‐radial method: an emerging alternative to CT‐guided biopsy in suspected lung cancer. A prospective case series and description of technique

    PubMed Central

    Yap, Elaine

    2017-01-01

    In diagnosing peripheral pulmonary lesions (PPL), radial endobronchial ultrasound (R‐EBUS) is emerging as a safer method in comparison to CT‐guided biopsy. Despite the better safety profile, the yield of R‐EBUS remains lower (73%) than CT‐guided biopsy (90%) due to the smaller size of samples. We adopted a hybrid method by adding cryobiopsy via the R‐EBUS Guide Sheath (GS) to produce larger, non‐crushed samples to improve diagnostic capability and enhance molecular testing. We report six prospective patients who underwent this procedure in our institution. R‐EBUS samples were obtained via conventional sampling methods (needle aspiration, forceps biopsy, and cytology brush), followed by a cryobiopsy. An endobronchial blocker was placed near the planned area of biopsy in advance and inflated post‐biopsy to minimize the risk of bleeding in all patients. A chest X‐ray was performed 1 h post‐procedure. All the PPLs were visualized with R‐EBUS. The mean diameter of cryobiopsy samples was twice the size of forceps biopsy samples. In four patients, cryobiopsy samples were superior in size and the number of malignant cells per high power filed and was the preferred sample selected for mutation analysis and molecular testing. There was no pneumothorax or significant bleeding to report. Cryobiopsy samples were consistently larger and were the preferred samples for molecular testing, with an increase in the diagnostic yield and reduction in the need for repeat procedures, without hindering the marked safety profile of R‐EBUS. Using an endobronchial blocker improves the safety of this procedure. PMID:29321931

  18. The program structure does not reliably recover the correct population structure when sampling is uneven: subsampling and new estimators alleviate the problem.

    PubMed

    Puechmaille, Sebastien J

    2016-05-01

    Inferences of population structure and more precisely the identification of genetically homogeneous groups of individuals are essential to the fields of ecology, evolutionary biology and conservation biology. Such population structure inferences are routinely investigated via the program structure implementing a Bayesian algorithm to identify groups of individuals at Hardy-Weinberg and linkage equilibrium. While the method is performing relatively well under various population models with even sampling between subpopulations, the robustness of the method to uneven sample size between subpopulations and/or hierarchical levels of population structure has not yet been tested despite being commonly encountered in empirical data sets. In this study, I used simulated and empirical microsatellite data sets to investigate the impact of uneven sample size between subpopulations and/or hierarchical levels of population structure on the detected population structure. The results demonstrated that uneven sampling often leads to wrong inferences on hierarchical structure and downward-biased estimates of the true number of subpopulations. Distinct subpopulations with reduced sampling tended to be merged together, while at the same time, individuals from extensively sampled subpopulations were generally split, despite belonging to the same panmictic population. Four new supervised methods to detect the number of clusters were developed and tested as part of this study and were found to outperform the existing methods using both evenly and unevenly sampled data sets. Additionally, a subsampling strategy aiming to reduce sampling unevenness between subpopulations is presented and tested. These results altogether demonstrate that when sampling evenness is accounted for, the detection of the correct population structure is greatly improved. © 2016 John Wiley & Sons Ltd.

  19. Evaluation of the Thermo Scientific SureTect Salmonella species assay. AOAC Performance Tested Method 051303.

    PubMed

    Cloke, Jonathan; Clark, Dorn; Radcliff, Roy; Leon-Velarde, Carlos; Larson, Nathan; Dave, Keron; Evans, Katharine; Crabtree, David; Hughes, Annette; Simpson, Helen; Holopainen, Jani; Wickstrand, Nina; Kauppinen, Mikko

    2014-01-01

    The Thermo Scientific SureTect Salmonella species Assay is a new real-time PCR assay for the detection of Salmonellae in food and environmental samples. This validation study was conducted using the AOAC Research Institute (RI) Performance Tested Methods program to validate the SureTect Salmonella species Assay in comparison to the reference method detailed in International Organization for Standardization 6579:2002 in a variety of food matrixes, namely, raw ground beef, raw chicken breast, raw ground pork, fresh bagged lettuce, pork frankfurters, nonfat dried milk powder, cooked peeled shrimp, pasteurized liquid whole egg, ready-to-eat meal containing beef, and stainless steel surface samples. With the exception of liquid whole egg and fresh bagged lettuce, which were tested in-house, all matrixes were tested by Marshfield Food Safety, Marshfield, WI, on behalf of Thermo Fisher Scientific. In addition, three matrixes (pork frankfurters, lettuce, and stainless steel surface samples) were analyzed independently as part of the AOAC-RI-controlled laboratory study by the University of Guelph, Canada. No significant difference by probability of detection or McNemars Chi-squared statistical analysis was found between the candidate or reference methods for any of the food matrixes or environmental surface samples tested during the validation study. Inclusivity and exclusivity testing was conducted with 117 and 36 isolates, respectively, which demonstrated that the SureTect Salmonella species Assay was able to detect all the major groups of Salmonella enterica subspecies enterica (e.g., Typhimurium) and the less common subspecies of S. enterica (e.g., arizoniae) and the rarely encountered S. bongori. None of the exclusivity isolates analyzed were detected by the SureTect Salmonella species Assay. Ruggedness testing was conducted to evaluate the performance of the assay with specific method deviations outside of the recommended parameters open to variation (enrichment time and temperature, and lysis temperature), which demonstrated that the assay gave reliable performance. Accelerated stability testing was additionally conducted, validating the assay shelf life.

  20. Resampling-based Methods in Single and Multiple Testing for Equality of Covariance/Correlation Matrices

    PubMed Central

    Yang, Yang; DeGruttola, Victor

    2016-01-01

    Traditional resampling-based tests for homogeneity in covariance matrices across multiple groups resample residuals, that is, data centered by group means. These residuals do not share the same second moments when the null hypothesis is false, which makes them difficult to use in the setting of multiple testing. An alternative approach is to resample standardized residuals, data centered by group sample means and standardized by group sample covariance matrices. This approach, however, has been observed to inflate type I error when sample size is small or data are generated from heavy-tailed distributions. We propose to improve this approach by using robust estimation for the first and second moments. We discuss two statistics: the Bartlett statistic and a statistic based on eigen-decomposition of sample covariance matrices. Both statistics can be expressed in terms of standardized errors under the null hypothesis. These methods are extended to test homogeneity in correlation matrices. Using simulation studies, we demonstrate that the robust resampling approach provides comparable or superior performance, relative to traditional approaches, for single testing and reasonable performance for multiple testing. The proposed methods are applied to data collected in an HIV vaccine trial to investigate possible determinants, including vaccine status, vaccine-induced immune response level and viral genotype, of unusual correlation pattern between HIV viral load and CD4 count in newly infected patients. PMID:22740584

  1. Resampling-based methods in single and multiple testing for equality of covariance/correlation matrices.

    PubMed

    Yang, Yang; DeGruttola, Victor

    2012-06-22

    Traditional resampling-based tests for homogeneity in covariance matrices across multiple groups resample residuals, that is, data centered by group means. These residuals do not share the same second moments when the null hypothesis is false, which makes them difficult to use in the setting of multiple testing. An alternative approach is to resample standardized residuals, data centered by group sample means and standardized by group sample covariance matrices. This approach, however, has been observed to inflate type I error when sample size is small or data are generated from heavy-tailed distributions. We propose to improve this approach by using robust estimation for the first and second moments. We discuss two statistics: the Bartlett statistic and a statistic based on eigen-decomposition of sample covariance matrices. Both statistics can be expressed in terms of standardized errors under the null hypothesis. These methods are extended to test homogeneity in correlation matrices. Using simulation studies, we demonstrate that the robust resampling approach provides comparable or superior performance, relative to traditional approaches, for single testing and reasonable performance for multiple testing. The proposed methods are applied to data collected in an HIV vaccine trial to investigate possible determinants, including vaccine status, vaccine-induced immune response level and viral genotype, of unusual correlation pattern between HIV viral load and CD4 count in newly infected patients.

  2. Alkaline peptone water enrichment with a dipstick test to quickly detect and monitor cholera outbreaks.

    PubMed

    Bwire, Godfrey; Orach, Christopher Garimoi; Abdallah, Dauda; Debes, Amanda Kay; Kagirita, Atek; Ram, Malathi; Sack, David A

    2017-11-21

    Detection, confirmation and monitoring of cholera outbreaks in many developing countries including Uganda is a big challenge due to lack of the required resources and the time the test takes. Culture method which takes 24-48 h to get the feedback and requires highly skilled laboratory staff plus other complex resources is the standard test. This study evaluated the new cholera rapid detection method that relies on Crystal VC dipsticks after enrichment with alkaline peptone water (APW) against the culture method for monitoring the progress of cholera outbreaks in rural setting. We conducted the study between March and June 2015. Fresh stool samples and rectal swabs were incubated in 1% APW for 6 h at room temperature before testing with RDT following the manufacturer's instruction. The same stool sample was cultured to isolate V. cholerae in the standard manner. We also reviewed patient registers to epidemiologically describe the cholera epidemic. We tested stool from 102 consenting suspected cholera patients reporting during daytime at Bwera Hospital (n = 69), Kilembe Mines Hospital (n = 4) and Kinyabwama Health Centre (n = 29). Ninety one (91) samples were positive and nine samples were negative according to both methods. One (1) sample was positive only by dipstick and one sample was positive only by culture (sensitivity of 99%, specificity of 90%, Positive Predictive Value of 99% and Negative Predictive Value of 90%). Overall, 146 suspected cholera cases and two deaths, (case fatality rate of 1.36%) were recorded during the study period. Among the cases aged 1-9 years, 63% (50/79) were males while in those aged 20-49 years, 76% (34/45) were females. Our findings showed that the modified dipstick test after enrichment with 1% APW had high level of accuracy in detection of V. cholerae and is quick, affordable alternative cholera outbreak monitoring tool in resource constrained settings. However, culture method should remain for cholera epidemic confirmation, for monitoring of antibiotic sensitivity and for production of pure isolates for molecular characterization. Further studies should be done to better understand the observed age and sex case distribution, in Kasese district.

  3. 40 CFR Appendix B to Part 61 - Test Methods

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... below 28 liters/min (1.0 cfm). 8.2.2Perform test runs such that samples are obtained over a period or... cyclic operations, run sufficient tests for the accurate determination of the emissions that occur over... indicated by reddening (liberation of free iodine) in the first impinger. In these cases, the sample run may...

  4. 40 CFR Appendix B to Part 61 - Test Methods

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... below 28 liters/min (1.0 cfm). 8.2.2Perform test runs such that samples are obtained over a period or... cyclic operations, run sufficient tests for the accurate determination of the emissions that occur over... indicated by reddening (liberation of free iodine) in the first impinger. In these cases, the sample run may...

  5. 40 CFR Appendix B to Part 61 - Test Methods

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... below 28 liters/min (1.0 cfm). 8.2.2Perform test runs such that samples are obtained over a period or... cyclic operations, run sufficient tests for the accurate determination of the emissions that occur over... indicated by reddening (liberation of free iodine) in the first impinger. In these cases, the sample run may...

  6. 40 CFR Appendix B to Part 61 - Test Methods

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... below 28 liters/min (1.0 cfm). 8.2.2Perform test runs such that samples are obtained over a period or... cyclic operations, run sufficient tests for the accurate determination of the emissions that occur over... indicated by reddening (liberation of free iodine) in the first impinger. In these cases, the sample run may...

  7. 40 CFR Appendix B to Part 61 - Test Methods

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... below 28 liters/min (1.0 cfm). 8.2.2Perform test runs such that samples are obtained over a period or... cyclic operations, run sufficient tests for the accurate determination of the emissions that occur over... indicated by reddening (liberation of free iodine) in the first impinger. In these cases, the sample run may...

  8. Sample Size Calculation for Estimating or Testing a Nonzero Squared Multiple Correlation Coefficient

    ERIC Educational Resources Information Center

    Krishnamoorthy, K.; Xia, Yanping

    2008-01-01

    The problems of hypothesis testing and interval estimation of the squared multiple correlation coefficient of a multivariate normal distribution are considered. It is shown that available one-sided tests are uniformly most powerful, and the one-sided confidence intervals are uniformly most accurate. An exact method of calculating sample size to…

  9. Model Choice and Sample Size in Item Response Theory Analysis of Aphasia Tests

    ERIC Educational Resources Information Center

    Hula, William D.; Fergadiotis, Gerasimos; Martin, Nadine

    2012-01-01

    Purpose: The purpose of this study was to identify the most appropriate item response theory (IRT) measurement model for aphasia tests requiring 2-choice responses and to determine whether small samples are adequate for estimating such models. Method: Pyramids and Palm Trees (Howard & Patterson, 1992) test data that had been collected from…

  10. Inverse sampling regression for pooled data.

    PubMed

    Montesinos-López, Osval A; Montesinos-López, Abelardo; Eskridge, Kent; Crossa, José

    2017-06-01

    Because pools are tested instead of individuals in group testing, this technique is helpful for estimating prevalence in a population or for classifying a large number of individuals into two groups at a low cost. For this reason, group testing is a well-known means of saving costs and producing precise estimates. In this paper, we developed a mixed-effect group testing regression that is useful when the data-collecting process is performed using inverse sampling. This model allows including covariate information at the individual level to incorporate heterogeneity among individuals and identify which covariates are associated with positive individuals. We present an approach to fit this model using maximum likelihood and we performed a simulation study to evaluate the quality of the estimates. Based on the simulation study, we found that the proposed regression method for inverse sampling with group testing produces parameter estimates with low bias when the pre-specified number of positive pools (r) to stop the sampling process is at least 10 and the number of clusters in the sample is also at least 10. We performed an application with real data and we provide an NLMIXED code that researchers can use to implement this method.

  11. Reduced detection by Ziehl-Neelsen method of acid-fast bacilli in sputum samples preserved in cetylpyridinium chloride solution.

    PubMed

    Selvakumar, N; Sudhamathi, S; Duraipandian, M; Frieden, T R; Narayanan, P R

    2004-02-01

    Twelve health facilities implementing the DOTS strategy, and the Tuberculosis Research Centre (TRC), Chennai, India. To determine the detection rates using Ziehl-Neelsen (ZN) and auramine-phenol to stain acid-fast bacilli (AFB) in sputum samples stored in cetylpyridinium chloride (CPC) solution. Two smears were prepared from each of 988 sputum samples collected in CPC and randomly allocated, one to ZN and the other to auramine-phenol staining. All samples were processed for culture of Mycobacterium tuberculosis. A significantly higher proportion of samples were negative using the ZN method compared to the auramine-phenol method (74.5% vs. 61.8%, McNamara's paired chi2 test; P < 0.001). Among 377 samples that were positive using auramine-phenol, 44% were negative using ZN. There were more culture-positive, smear-negative samples in ZN (52.7%) than in auramine-phenol (30%); the difference attained statistical significance (McNemar's paired chi2 test; P < 0.00004). Using ZN, of the 104 smears made immediately after collection, 52 were positive for AFB, of which only 35 (67.3%) were positive after storage in CPC; the reduction in the number of positive smears attained statistical significance (McNemar's paired chi2 test; P = 0.004). Detection of AFB in sputum samples preserved in CPC is significantly reduced using ZN staining.

  12. Bayesian inference for disease prevalence using negative binomial group testing

    PubMed Central

    Pritchard, Nicholas A.; Tebbs, Joshua M.

    2011-01-01

    Group testing, also known as pooled testing, and inverse sampling are both widely used methods of data collection when the goal is to estimate a small proportion. Taking a Bayesian approach, we consider the new problem of estimating disease prevalence from group testing when inverse (negative binomial) sampling is used. Using different distributions to incorporate prior knowledge of disease incidence and different loss functions, we derive closed form expressions for posterior distributions and resulting point and credible interval estimators. We then evaluate our new estimators, on Bayesian and classical grounds, and apply our methods to a West Nile Virus data set. PMID:21259308

  13. 40 CFR 80.582 - What are the sampling and testing methods for the fuel marker?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... marker content of distillate fuels and how will EPA qualify or decline to qualify a test method?—(1... developed by a Voluntary Consensus-Based Standards Body, such as the American Society for Testing and... this standard from the American Society for Testing and Materials, 100 Barr Harbor Dr., West...

  14. 40 CFR 80.582 - What are the sampling and testing methods for the fuel marker?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... marker content of distillate fuels and how will EPA qualify or decline to qualify a test method?—(1... developed by a Voluntary Consensus-Based Standards Body, such as the American Society for Testing and... this standard from the American Society for Testing and Materials, 100 Barr Harbor Dr., West...

  15. 40 CFR 80.582 - What are the sampling and testing methods for the fuel marker?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... marker content of distillate fuels and how will EPA qualify or decline to qualify a test method?—(1... developed by a Voluntary Consensus-Based Standards Body, such as the American Society for Testing and... this standard from the American Society for Testing and Materials, 100 Barr Harbor Dr., West...

  16. Detection of Cryptosporidium oocysts in fresh and frozen cattle faeces: comparison of three methods.

    PubMed

    Brook, E J; Christley, R M; French, N P; Hart, C A

    2008-01-01

    The aim of this study was to compare the performance of three commonly used screening tests for Cryptosporidium oocysts in fresh and frozen cattle faeces. Twenty-nine freshly voided faecal samples were collected from calves from three farms in the northwest of England. Three diagnostic tests for Cryptosporidium were carried out on each sample both before and after freezing - the modified Ziehl-Neelsen (MZN) and auramine phenol (APh) stains and a commercial enzyme immunoassay (EIA) kit, the ProSpecT Cryptosporidium Microplate assay (Remel, Lenexa, KS). Twelve samples were deemed positive by the reference standard (polymerase chain reaction, PCR). There were some discrepancies between the results of the screening tests and the levels of agreement were quantified. The sensitivity and specificity of each method was determined, with PCR as the gold standard. Sensitivity and specificity of the MZN stain was optimized when samples with fewer than two oocyst-like bodies were classified as negative. All three screening methods used were effective in detecting Cryptosporidium infection in both fresh and frozen calf faeces. This study has highlighted the value of determining characteristics of tests used for diagnosis and epidemiological studies.

  17. Core Cutting Test with Vertical Rock Cutting Rig (VRCR)

    NASA Astrophysics Data System (ADS)

    Yasar, Serdar; Osman Yilmaz, Ali

    2017-12-01

    Roadheaders are frequently used machines in mining and tunnelling, and performance prediction of roadheaders is important for project economics and stability. Several methods were proposed so far for this purpose and, rock cutting tests are the best choice. Rock cutting tests are generally divided into two groups which are namely, full scale rock cutting tests and small scale rock cutting tests. These two tests have some superiorities and deficiencies over themselves. However, in many cases, where rock sampling becomes problematic, small scale rock cutting test (core cutting test) is preferred for performance prediction, since small block samples and core samples can be conducted to rock cutting testing. Common problem for rock cutting tests are that they can be found in very limited research centres. In this study, a new mobile rock cutting testing equipment, vertical rock cutting rig (VRCR) was introduced. Standard testing procedure was conducted on seven rock samples which were the part of a former study on cutting rocks with another small scale rock cutting test. Results showed that core cutting test can be realized successfully with VRCR with the validation of paired samples t-test.

  18. Method for digital measurement of phase-frequency characteristics for a fixed-length ultrasonic spectrometer

    NASA Astrophysics Data System (ADS)

    Astashev, M. E.; Belosludtsev, K. N.; Kharakoz, D. P.

    2014-05-01

    One of the most accurate methods for measuring the compressibility of liquids is resonance measurement of sound velocity in a fixed-length interferometer. This method combines high sensitivity, accuracy, and small sample volume of the test liquid. The measuring principle is to study the resonance properties of a composite resonator that contains a test liquid sample. Ealier, the phase-locked loop (PLL) scheme was used for this. In this paper, we propose an alternative measurement scheme based on digital analysis of harmonic signals, describe the implementation of this scheme using commercially available data acquisition modules, and give examples of test measurements with accuracy evaluations of the results.

  19. Pilot Test of a Novel Method for Assessing Community Response to Low-Amplitude Sonic Booms

    NASA Technical Reports Server (NTRS)

    Fidell, Sanford; Horonjeff, Richard D.; Harris, Michael

    2012-01-01

    A pilot test of a novel method for assessing residents annoyance to sonic booms was performed. During a two-week period, residents of the base housing area at Edwards Air Force Base provided data on their reactions to sonic booms using Smartphone-based interviews. Noise measurements were conducted at the same time. The report presents information about data collection methods and about test participants reactions to low-amplitude sonic booms. The latter information should not be viewed as definitive for several reasons. It may not be reliably generalized to the wider U.S. residential population (because it was not derived from a representative random sample) and the sample itself was not large.

  20. An investigative comparison of purging and non-purging groundwater sampling methods in Karoo aquifer monitoring wells

    NASA Astrophysics Data System (ADS)

    Gomo, M.; Vermeulen, D.

    2015-03-01

    An investigation was conducted to statistically compare the influence of non-purging and purging groundwater sampling methods on analysed inorganic chemistry parameters and calculated saturation indices. Groundwater samples were collected from 15 monitoring wells drilled in Karoo aquifers before and after purging for the comparative study. For the non-purging method, samples were collected from groundwater flow zones located in the wells using electrical conductivity (EC) profiling. The two data sets of non-purged and purged groundwater samples were analysed for inorganic chemistry parameters at the Institute of Groundwater Studies (IGS) laboratory of the Free University in South Africa. Saturation indices for mineral phases that were found in the data base of PHREEQC hydrogeochemical model were calculated for each data set. Four one-way ANOVA tests were conducted using Microsoft excel 2007 to investigate if there is any statistically significant difference between: (1) all inorganic chemistry parameters measured in the non-purged and purged groundwater samples per each specific well, (2) all mineral saturation indices calculated for the non-purged and purged groundwater samples per each specific well, (3) individual inorganic chemistry parameters measured in the non-purged and purged groundwater samples across all wells and (4) Individual mineral saturation indices calculated for non-purged and purged groundwater samples across all wells. For all the ANOVA tests conducted, the calculated alpha values (p) are greater than 0.05 (significance level) and test statistic (F) is less than the critical value (Fcrit) (F < Fcrit). The results imply that there was no statistically significant difference between the two data sets. With a 95% confidence, it was therefore concluded that the variance between groups was rather due to random chance and not to the influence of the sampling methods (tested factor). It is therefore be possible that in some hydrogeologic conditions, non-purged groundwater samples might be just as representative as the purged ones. The findings of this study can provide an important platform for future evidence oriented research investigations to establish the necessity of purging prior to groundwater sampling in different aquifer systems.

  1. Use of the Analysis of the Volatile Faecal Metabolome in Screening for Colorectal Cancer

    PubMed Central

    2015-01-01

    Diagnosis of colorectal cancer is an invasive and expensive colonoscopy, which is usually carried out after a positive screening test. Unfortunately, existing screening tests lack specificity and sensitivity, hence many unnecessary colonoscopies are performed. Here we report on a potential new screening test for colorectal cancer based on the analysis of volatile organic compounds (VOCs) in the headspace of faecal samples. Faecal samples were obtained from subjects who had a positive faecal occult blood sample (FOBT). Subjects subsequently had colonoscopies performed to classify them into low risk (non-cancer) and high risk (colorectal cancer) groups. Volatile organic compounds were analysed by selected ion flow tube mass spectrometry (SIFT-MS) and then data were analysed using both univariate and multivariate statistical methods. Ions most likely from hydrogen sulphide, dimethyl sulphide and dimethyl disulphide are statistically significantly higher in samples from high risk rather than low risk subjects. Results using multivariate methods show that the test gives a correct classification of 75% with 78% specificity and 72% sensitivity on FOBT positive samples, offering a potentially effective alternative to FOBT. PMID:26086914

  2. 40 CFR 60.446 - Test methods and procedures.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the web substrate. (b) Method 25 shall be used to determine the VOC concentration, in parts per... equivalent, and each effluent gas stream emitted directly to the atmosphere. Methods 1, 2, 3, and 4 shall be... minimum sampling volume must be 0.003 dscm except that shorter sampling times or smaller volumes, when...

  3. 40 CFR 60.446 - Test methods and procedures.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... the web substrate. (b) Method 25 shall be used to determine the VOC concentration, in parts per... equivalent, and each effluent gas stream emitted directly to the atmosphere. Methods 1, 2, 3, and 4 shall be... minimum sampling volume must be 0.003 dscm except that shorter sampling times or smaller volumes, when...

  4. Rapid Salmonella detection in experimentally inoculated equine faecal and veterinary hospital environmental samples using commercially available lateral flow immunoassays.

    PubMed

    Burgess, B A; Noyes, N R; Bolte, D S; Hyatt, D R; van Metre, D C; Morley, P S

    2015-01-01

    Salmonella enterica is the most commonly reported cause of outbreaks of nosocomial infections in large animal veterinary teaching hospitals and the closure of equine hospitals. Rapid detection may facilitate effective control practices in equine populations. Shipping and laboratory testing typically require ≥48 h to obtain results. Lateral flow immunoassays developed for use in food-safety microbiology provide an alternative that has not been evaluated for use with faeces or environmental samples. We aimed to identify enrichment methods that would allow commercially available rapid Salmonella detection systems (lateral flow immunoassays) to be used in clinical practice with equine faecal and environmental samples, providing test results in 18-24 h. In vitro experiment. Equine faecal and environmental samples were inoculated with known quantities of S. enterica serotype Typhimurium and cultured using 2 different enrichment techniques for faeces and 4 enrichment techniques for environmental samples. Samples were tested blindly using 2 different lateral flow immunoassays and plated on agar media for confirmatory testing. In general, commercial lateral flow immunoassays resulted in fewer false-negative test results with enrichment of 1 g faecal samples in tetrathionate for 18 h, while all environmental sample enrichment techniques resulted in similar detection rates. The limit of detection from spiked samples, ∼4 colony-forming units/g, was similar for all methods evaluated. The lateral flow immunoassays evaluated could reliably detect S. enterica within 18 h, indicating that they may be useful for rapid point-of-care testing in equine practice applications. Additional evaluation is needed using samples from naturally infected cases and the environment to gain an accurate estimate of test sensitivity and specificity and to substantiate further the true value of these tests in clinical practice. © 2014 EVJ Ltd.

  5. Monoclonal antibodies to synthetic pyrethroids and method for detecting the same

    DOEpatents

    Stanker, Larry H.; Vanderlaan, Martin; Watkins, Bruce E.; Van Emon, Jeanette M.; Bigbee, Carolyn L.

    1992-01-01

    Methods are described for making specific monoclonal antibodies which may be used in a sensitive immunoassay for detection of synthetic pyrethroids in foods and environmental samples. Appropriate sample preparation and enzyme amplification of the immunoassay for this widely-used class of pesticides permits detection at low levels in laboratory and field tested samples.

  6. Monoclonal antibodies to synthetic pyrethroids and method for detecting the same

    DOEpatents

    Stanker, L.H.; Vanderlaan, M.; Watkins, B.E.; Van Emon, J.M.; Bigbee, C.L.

    1992-04-28

    Methods are described for making specific monoclonal antibodies which may be used in a sensitive immunoassay for detection of synthetic pyrethroids in foods and environmental samples. Appropriate sample preparation and enzyme amplification of the immunoassay for this widely-used class of pesticides permits detection at low levels in laboratory and field tested samples. 6 figs.

  7. EVALUATION OF IMMUNOASSAY METHODS FOR DETERMINATION OF 3,5,6-TRICHLORO-2-PYRIDINOL IN MULTIPLE SAMPLE MEDIA

    EPA Science Inventory

    Two enzyme-linked immunosorbent assay (ELISA) methods were evaluated for the determination of 3,5,6-trichloro-2-pyridinol (3,5,6-TCP) in multiple sample media (dust, soil, food, and urine). The dust and soil samples were analyzed by the RaPID (TM) commercial immunoassay testing ...

  8. Evaluation of a low-cost liquid-based Pap test in rural El Salvador: a split-sample study.

    PubMed

    Guo, Jin; Cremer, Miriam; Maza, Mauricio; Alfaro, Karla; Felix, Juan C

    2014-04-01

    We sought to test the diagnostic efficacy of a low-cost, liquid-based cervical cytology that could be implemented in low-resource settings. A prospective, split-sample Pap study was performed in 595 women attending a cervical cancer screening clinic in rural El Salvador. Collected cervical samples were used to make a conventional Pap (cell sample directly to glass slide), whereas residual material was used to make the liquid-based sample using the ClearPrep method. Selected samples were tested from the residual sample of the liquid-based collection for the presence of high-risk Human papillomaviruses. Of 595 patients, 570 were interpreted with the same diagnosis between the 2 methods (95.8% agreement). There were comparable numbers of unsatisfactory cases; however, ClearPrep significantly increased detection of low-grade squamous intraepithelial lesions and decreased the diagnoses of atypical squamous cells of undetermined significance. ClearPrep identified an equivalent number of high-grade squamous intraepithelial lesion cases as the conventional Pap. High-risk human papillomavirus was identified in all cases of high-grade squamous intraepithelial lesion, adenocarcinoma in situ, and cancer as well as in 78% of low-grade squamous intraepithelial lesions out of the residual fluid of the ClearPrep vials. The low-cost ClearPrep Pap test demonstrated equivalent detection of squamous intraepithelial lesions when compared with the conventional Pap smear and demonstrated the potential for ancillary molecular testing. The test seems a viable option for implementation in low-resource settings.

  9. Evaluation of a quantitative H2S MPN test for fecal microbes analysis of water using biochemical and molecular identification.

    PubMed

    McMahan, Lanakila; Grunden, Amy M; Devine, Anthony A; Sobsey, Mark D

    2012-04-15

    The sensitivity and specificity of the H(2)S test to detect fecal bacteria in water has been variable and uncertain in previous studies, partly due to its presence-absence results. Furthermore, in groundwater samples false-positive results have been reported, with H(2)S-positive samples containing no fecal coliforms or Escherichia coli. False-negative results also have been reported in other studies, with H(2)S-negative samples found to contain E. coli. Using biochemical and molecular methods and a novel quantitative test format, this research identified the types and numbers of microbial community members present in natural water samples, including fecal indicators and pathogens as well as other bacteria. Representative water sources tested in this study included cistern rainwater, a protected lake, and wells in agricultural and forest settings. Samples from quantitative H(2)S tests of water were further cultured for fecal bacteria by spread plating onto the selective media for detection and isolation of Aeromonas spp., E. coli, Clostridium spp., H(2)S-producers, and species of Salmonella and Shigella. Isolates were then tested for H(2)S production, and identified to the genus and species level using biochemical methods. Terminal Restriction Fragment Length Polymorphisms (TRFLP) was the molecular method employed to quantitatively characterize microbial community diversity. Overall, it was shown that water samples testing positive for H(2)S bacteria also had bacteria of likely fecal origin and waters containing fecal pathogens also were positive for H(2)S bacteria. Of the microorganisms isolated from natural water, greater than 70 percent were identified using TRFLP analysis to reveal a relatively stable group of organisms whose community composition differed with water source and over time. These results further document the validity of the H(2)S test for detecting and quantifying fecal contamination of water. Copyright © 2011 Elsevier Ltd. All rights reserved.

  10. Comparison of Collection Methods for Fecal Samples in Microbiome Studies

    PubMed Central

    Vogtmann, Emily; Chen, Jun; Amir, Amnon; Shi, Jianxin; Abnet, Christian C.; Nelson, Heidi; Knight, Rob; Chia, Nicholas; Sinha, Rashmi

    2017-01-01

    Prospective cohort studies are needed to assess the relationship between the fecal microbiome and human health and disease. To evaluate fecal collection methods, we determined technical reproducibility, stability at ambient temperature, and accuracy of 5 fecal collection methods (no additive, 95% ethanol, RNAlater Stabilization Solution, fecal occult blood test cards, and fecal immunochemical test tubes). Fifty-two healthy volunteers provided fecal samples at the Mayo Clinic in Rochester, Minnesota, in 2014. One set from each sample collection method was frozen immediately, and a second set was incubated at room temperature for 96 hours and then frozen. Intraclass correlation coefficients (ICCs) were calculated for the relative abundance of 3 phyla, 2 alpha diversity metrics, and 4 beta diversity metrics. Technical reproducibility was high, with ICCs for duplicate fecal samples between 0.64 and 1.00. Stability for most methods was generally high, although the ICCs were below 0.60 for 95% ethanol in metrics that were more sensitive to relative abundance. When compared with fecal samples that were frozen immediately, the ICCs were below 0.60 for the metrics that were sensitive to relative abundance; however, the remaining 2 alpha diversity and 3 beta diversity metrics were all relatively accurate, with ICCs above 0.60. In conclusion, all fecal sample collection methods appear relatively reproducible, stable, and accurate. Future studies could use these collection methods for microbiome analyses. PMID:27986704

  11. Comparison of diagnostic techniques for the detection of Cryptosporidium oocysts in animal samples

    PubMed Central

    Mirhashemi, Marzieh Ezzaty; Zintl, Annetta; Grant, Tim; Lucy, Frances E.; Mulcahy, Grace; De Waal, Theo

    2015-01-01

    While a large number of laboratory methods for the detection of Cryptosporidium oocysts in faecal samples are now available, their efficacy for identifying asymptomatic cases of cryptosporidiosis is poorly understood. This study was carried out to determine a reliable screening test for epidemiological studies in livestock. In addition, three molecular tests were compared to identify Cryptosporidium species responsible for the infection in cattle, sheep and horses. A variety of diagnostic tests including microscopic (Kinyoun's staining), immunological (Direct Fluorescence Antibody tests or DFAT), enzyme-linked immunosorbent assay (ELISA), and molecular methods (nested PCR) were compared to assess their ability to detect Cryptosporidium in cattle, horse and sheep faecal samples. The results indicate that the sensitivity and specificity of each test is highly dependent on the input samples; while Kinyoun's and DFAT proved to be reliable screening tools for cattle samples, DFAT and PCR analysis (targeted at the 18S rRNA gene fragment) were more sensitive for screening sheep and horse samples. Finally different PCR primer sets targeted at the same region resulted in the preferential amplification of certain Cryptosporidium species when multiple species were present in the sample. Therefore, for identification of Cryptosporidium spp. in the event of asymptomatic cryptosporidiosis, the combination of different 18S rRNA nested PCR primer sets is recommended for further epidemiological applications and also tracking the sources of infection. PMID:25662435

  12. [Blood sampling using "dried blood spot": a clinical biology revolution underway?].

    PubMed

    Hirtz, Christophe; Lehmann, Sylvain

    2015-01-01

    Blood testing using the dried blood spot (DBS) is used since the 1960s in clinical analysis, mainly within the framework of the neonatal screening (Guthrie test). Since then numerous analytes such as nucleic acids, small molecules or lipids, were successfully measured on the DBS. While this pre-analytical method represents an interesting alternative to classic blood sampling, its use in routine is still limited. We review here the different clinical applications of the blood sampling on DBS and estimate its future place, supported by the new methods of analysis as the LC-MS mass spectrometry.

  13. Optimizing a Test Method to Evaluate Resistance of Pervious Concrete to Cycles of Freezing and Thawing in the Presence of Different Deicing Salts

    PubMed Central

    Tsang, Chehong; Shehata, Medhat H.; Lotfy, Abdurrahmaan

    2016-01-01

    The lack of a standard test method for evaluating the resistance of pervious concrete to cycles of freezing and thawing in the presence of deicing salts is the motive behind this study. Different sample size and geometry, cycle duration, and level of submersion in brine solutions were investigated to achieve an optimized test method. The optimized test method was able to produce different levels of damage when different types of deicing salts were used. The optimized duration of one cycle was found to be 24 h with twelve hours of freezing at −18 °C and twelve hours of thawing at +21 °C, with the bottom 10 mm of the sample submerged in the brine solution. Cylinder samples with a diameter of 100 mm and height of 150 mm were used and found to produce similar results to 150 mm-cubes. Based on the obtained results a mass loss of 3%–5% is proposed as a failure criterion of cylindrical samples. For the materials and within the cycles of freezing/thawing investigated here, the deicers that caused the most damage were NaCl, CaCl2 and urea, followed by MgCl2, potassium acetate, sodium acetate and calcium-magnesium acetate. More testing is needed to validate the effects of different deicers under long term exposures and different temperature ranges. PMID:28773998

  14. Large strain cruciform biaxial testing for FLC detection

    NASA Astrophysics Data System (ADS)

    Güler, Baran; Efe, Mert

    2017-10-01

    Selection of proper test method, specimen design and analysis method are key issues for studying formability of sheet metals and detection of their forming limit curves (FLC). Materials with complex microstructures may need an additional micro-mechanical investigation and accurate modelling. Cruciform biaxial test stands as an alternative to standard tests as it achieves frictionless, in-plane, multi-axial stress states with a single sample geometry. In this study, we introduce a small-scale (less than 10 cm) cruciform sample allowing micro-mechanical investigation at stress states ranging from plane strain to equibiaxial. With successful specimen design and surface finish, large forming limit strains are obtained at the test region of the sample. The large forming limit strains obtained by experiments are compared to the values obtained from Marciniak-Kuczynski (M-K) local necking model and Cockroft-Latham damage model. This comparison shows that the experimental limiting strains are beyond the theoretical values, approaching to the fracture strain of the two test materials: Al-6061-T6 aluminum alloy and DC-04 high formability steel.

  15. Effects of disease severity distribution on the performance of quantitative diagnostic methods and proposal of a novel ‘V-plot’ methodology to display accuracy values

    PubMed Central

    Dehbi, Hakim-Moulay; Howard, James P; Shun-Shin, Matthew J; Sen, Sayan; Nijjer, Sukhjinder S; Mayet, Jamil; Davies, Justin E; Francis, Darrel P

    2018-01-01

    Background Diagnostic accuracy is widely accepted by researchers and clinicians as an optimal expression of a test’s performance. The aim of this study was to evaluate the effects of disease severity distribution on values of diagnostic accuracy as well as propose a sample-independent methodology to calculate and display accuracy of diagnostic tests. Methods and findings We evaluated the diagnostic relationship between two hypothetical methods to measure serum cholesterol (Cholrapid and Cholgold) by generating samples with statistical software and (1) keeping the numerical relationship between methods unchanged and (2) changing the distribution of cholesterol values. Metrics of categorical agreement were calculated (accuracy, sensitivity and specificity). Finally, a novel methodology to display and calculate accuracy values was presented (the V-plot of accuracies). Conclusion No single value of diagnostic accuracy can be used to describe the relationship between tests, as accuracy is a metric heavily affected by the underlying sample distribution. Our novel proposed methodology, the V-plot of accuracies, can be used as a sample-independent measure of a test performance against a reference gold standard. PMID:29387424

  16. Comparison of Parametric and Nonparametric Bootstrap Methods for Estimating Random Error in Equipercentile Equating

    ERIC Educational Resources Information Center

    Cui, Zhongmin; Kolen, Michael J.

    2008-01-01

    This article considers two methods of estimating standard errors of equipercentile equating: the parametric bootstrap method and the nonparametric bootstrap method. Using a simulation study, these two methods are compared under three sample sizes (300, 1,000, and 3,000), for two test content areas (the Iowa Tests of Basic Skills Maps and Diagrams…

  17. Testing the efficiency of rover science protocols for robotic sample selection: A GeoHeuristic Operational Strategies Test

    NASA Astrophysics Data System (ADS)

    Yingst, R. A.; Bartley, J. K.; Chidsey, T. C.; Cohen, B. A.; Gilleaudeau, G. J.; Hynek, B. M.; Kah, L. C.; Minitti, M. E.; Williams, R. M. E.; Black, S.; Gemperline, J.; Schaufler, R.; Thomas, R. J.

    2018-05-01

    The GHOST field tests are designed to isolate and test science-driven rover operations protocols, to determine best practices. During a recent field test at a potential Mars 2020 landing site analog, we tested two Mars Science Laboratory data-acquisition and decision-making methods to assess resulting science return and sample quality: a linear method, where sites of interest are studied in the order encountered, and a "walkabout-first" method, where sites of interest are examined remotely before down-selecting to a subset of sites that are interrogated with more resource-intensive instruments. The walkabout method cost less time and fewer resources, while increasing confidence in interpretations. Contextual data critical to evaluating site geology was acquired earlier than for the linear method, and given a higher priority, which resulted in development of more mature hypotheses earlier in the analysis process. Combined, this saved time and energy in the collection of data with more limited spatial coverage. Based on these results, we suggest that the walkabout method be used where doing so would provide early context and time for the science team to develop hypotheses-critical tests; and that in gathering context, coverage may be more important than higher resolution.

  18. Using microstructure observations to quantify fracture properties and improve reservoir simulations. Final report, September 1998

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laubach, S.E.; Marrett, R.; Rossen, W.

    The research for this project provides new technology to understand and successfully characterize, predict, and simulate reservoir-scale fractures. Such fractures have worldwide importance because of their influence on successful extraction of resources. The scope of this project includes creation and testing of new methods to measure, interpret, and simulate reservoir fractures that overcome the challenge of inadequate sampling. The key to these methods is the use of microstructures as guides to the attributes of the large fractures that control reservoir behavior. One accomplishment of the project research is a demonstration that these microstructures can be reliably and inexpensively sampled. Specificmore » goals of this project were to: create and test new methods of measuring attributes of reservoir-scale fractures, particularly as fluid conduits, and test the methods on samples from reservoirs; extrapolate structural attributes to the reservoir scale through rigorous mathematical techniques and help build accurate and useful 3-D models of the interwell region; and design new ways to incorporate geological and geophysical information into reservoir simulation and verify the accuracy by comparison with production data. New analytical methods developed in the project are leading to a more realistic characterization of fractured reservoir rocks. Testing diagnostic and predictive approaches was an integral part of the research, and several tests were successfully completed.« less

  19. Adhesives: Test Method, Group Assignment, and Categorization Guide for High-Loading-Rate Applications Preparation and Testing of Single Lap Joints (Ver. 2.2, Unlimited)

    DTIC Science & Technology

    2016-04-01

    Gerard Chaney, and Charles Pergantis Weapons and Materials Research Directorate, ARL Coatings, Corrosion, and Engineered Polymers Branch (CCEPB...SUBJECT TERMS single lap joint, adhesive, sample preparation, testing, database, metadata, material pedigree, ISO 16. SECURITY CLASSIFICATION OF: 17...temperature/water immersion conditioning test for lap-joint test specimens using the test tubes and convection oven method

  20. Quantitative Method for Analysis of Hydrocodone, Hydromorphone and Norhydrocodone in Human Plasma by Liquid Chromatography-tandem Mass Spectrometry

    DTIC Science & Technology

    2013-03-01

    ratio ranges obtained for the six standards. Twelve samples were analyzed to demonstrate the efficiency of the extraction procedure. Drug and internal...frozen (−70 ◦C). Refrigerated samples were tested after 2 months of storage ; frozen samples were tested for up to 1 year from stor- age date. The...freeze–thaw stability was evaluated by analyzing three subject samples with known drug concentrations and two quality control samples at concentrations

  1. Evaluation of the Ortho-Clinical Diagnostics Vitros ECi Anti-HCV test: comparison with three other methods.

    PubMed

    Watterson, Jeannette M; Stallcup, Paulina; Escamilla, David; Chernay, Patrick; Reyes, Alfred; Trevino, Sylvia C

    2007-01-01

    After observing a high incidence of low positive hepatitis C virus (HCV) antibody screens by the Ortho-Clinical Vitros ECi test (Orthoclinical Diagnostics, Raritan, NJ), we compared results against those obtained using another chemiluminescent analyzer, as well as two U.S. Food and Drug Administration (FDA)-approved confirmatory methodologies. To ascertain the true anti-HCV status of samples deemed low-positive by the Ortho-Clinical Vitros ECi test, we tested samples using the ADVIA Centaur HCV screen test (Siemens Medical Solutions Diagnostics), the Chiron recombinant immunoblot assay (RIBA) test (Chiron Corp., Emeryville, CA), and the Roche COBAS Amplicor HCV qualitative test (Roche Diagnostics, Indianapolis, IN) in a series of studies. Of 94 specimens positive by Vitros ECi, 19% were observed to be negative by Centaur. A separate study of 91 samples with signal-to-cutoff (s/co) values less than 8.0 showed that all but one was negative for HCV ribonucleic acid (RNA). In comparison with RIBA, 100% (77) samples positive by the Vitros ECi test with s/co values less than 12.0 were negative or indeterminate by RIBA. A final study comparing all four methods side-by-side showed 63% disagreement by Centaur for Vitros ECi low-positive samples, 75% disagreement by RIBA, and 97% disagreement by polymerase chain reaction (PCR). In conclusion, the Ortho-Clinical Vitros ECi Anti-HCV test yields a high rate of false-positive results in the low s/co range in our patient population. (c) 2007 Wiley-Liss, Inc.

  2. Evaluation of Polymerase Chain Reaction for Detecting Coliform Bacteria in Drinking Water Sources.

    PubMed

    Isfahani, Bahram Nasr; Fazeli, Hossein; Babaie, Zeinab; Poursina, Farkhondeh; Moghim, Sharareh; Rouzbahani, Meisam

    2017-01-01

    Coliform bacteria are used as indicator organisms for detecting fecal pollution in water. Traditional methods including microbial culture tests in lactose-containing media and enzyme-based tests for the detection of β-galactosidase; however, these methods are time-consuming and less specific. The aim of this study was to evaluate polymerase chain reaction (PCR) for detecting coliform. Totally, 100 of water samples from Isfahan drinking water source were collected. Coliform bacteria and Escherichia coli were detected in drinking water using LacZ and LamB genes in PCR method performed in comparison with biochemical tests for all samples. Using phenotyping, 80 coliform isolates were found. The results of the biochemical tests illustrated 78.7% coliform bacteria and 21.2% E. coli . PCR results for LacZ and LamB genes were 67.5% and 17.5%, respectively. The PCR method was shown to be an effective, sensitive, and rapid method for detecting coliform and E. coli in drinking water from the Isfahan drinking water sources.

  3. 76 FR 55842 - Partial Approval and Partial Disapproval of Air Quality Implementation Plans; California; San...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-09

    ... sometimes approves a rule only as a SIP strengthening action (e.g., to update definitions, add test methods... standards (e.g., materials specifications, test methods, sampling procedures, and business practices) that...

  4. Spectral feature characterization methods for blood stain detection in crime scene backgrounds

    NASA Astrophysics Data System (ADS)

    Yang, Jie; Mathew, Jobin J.; Dube, Roger R.; Messinger, David W.

    2016-05-01

    Blood stains are one of the most important types of evidence for forensic investigation. They contain valuable DNA information, and the pattern of the stains can suggest specifics about the nature of the violence that transpired at the scene. Blood spectral signatures containing unique reflectance or absorption features are important both for forensic on-site investigation and laboratory testing. They can be used for target detection and identification applied to crime scene hyperspectral imagery, and also be utilized to analyze the spectral variation of blood on various backgrounds. Non-blood stains often mislead the detection and can generate false alarms at a real crime scene, especially for dark and red backgrounds. This paper measured the reflectance of liquid blood and 9 kinds of non-blood samples in the range of 350 nm - 2500 nm in various crime scene backgrounds, such as pure samples contained in petri dish with various thicknesses, mixed samples with different colors and materials of fabrics, and mixed samples with wood, all of which are examined to provide sub-visual evidence for detecting and recognizing blood from non-blood samples in a realistic crime scene. The spectral difference between blood and non-blood samples are examined and spectral features such as "peaks" and "depths" of reflectance are selected. Two blood stain detection methods are proposed in this paper. The first method uses index to denote the ratio of "depth" minus "peak" over"depth" add"peak" within a wavelength range of the reflectance spectrum. The second method uses relative band depth of the selected wavelength ranges of the reflectance spectrum. Results show that the index method is able to discriminate blood from non-blood samples in most tested crime scene backgrounds, but is not able to detect it from black felt. Whereas the relative band depth method is able to discriminate blood from non-blood samples on all of the tested background material types and colors.

  5. Optimization of Sample Preparation for the Identification and Quantification of Saxitoxin in Proficiency Test Mussel Sample using Liquid Chromatography-Tandem Mass Spectrometry

    PubMed Central

    Harju, Kirsi; Rapinoja, Marja-Leena; Avondet, Marc-André; Arnold, Werner; Schär, Martin; Burrell, Stephen; Luginbühl, Werner; Vanninen, Paula

    2015-01-01

    Saxitoxin (STX) and some selected paralytic shellfish poisoning (PSP) analogues in mussel samples were identified and quantified with liquid chromatography-tandem mass spectrometry (LC-MS/MS). Sample extraction and purification methods of mussel sample were optimized for LC-MS/MS analysis. The developed method was applied to the analysis of the homogenized mussel samples in the proficiency test (PT) within the EQuATox project (Establishment of Quality Assurance for the Detection of Biological Toxins of Potential Bioterrorism Risk). Ten laboratories from eight countries participated in the STX PT. Identification of PSP toxins in naturally contaminated mussel samples was performed by comparison of product ion spectra and retention times with those of reference standards. The quantitative results were obtained with LC-MS/MS by spiking reference standards in toxic mussel extracts. The results were within the z-score of ±1 when compared to the results measured with the official AOAC (Association of Official Analytical Chemists) method 2005.06, pre-column oxidation high-performance liquid chromatography with fluorescence detection (HPLC-FLD). PMID:26610567

  6. Study samples are too small to produce sufficiently precise reliability coefficients.

    PubMed

    Charter, Richard A

    2003-04-01

    In a survey of journal articles, test manuals, and test critique books, the author found that a mean sample size (N) of 260 participants had been used for reliability studies on 742 tests. The distribution was skewed because the median sample size for the total sample was only 90. The median sample sizes for the internal consistency, retest, and interjudge reliabilities were 182, 64, and 36, respectively. The author presented sample size statistics for the various internal consistency methods and types of tests. In general, the author found that the sample sizes that were used in the internal consistency studies were too small to produce sufficiently precise reliability coefficients, which in turn could cause imprecise estimates of examinee true-score confidence intervals. The results also suggest that larger sample sizes have been used in the last decade compared with those that were used in earlier decades.

  7. Optimization and validation of a rapid method to determine citrate and inorganic phosphate in milk by capillary electrophoresis.

    PubMed

    Izco, J M; Tormo, M; Harris, A; Tong, P S; Jimenez-Flores, R

    2003-01-01

    Quantification of phosphate and citrate compounds is very important because their distribution between soluble and colloidal phases of milk and their interactions with milk proteins influence the stability and some functional properties of dairy products. The aim of this work was to optimize and validate a capillary electrophoresis method for the rapid determination of these compounds in milk. Various parameters affecting analysis have been optimized, including type, composition, and pH of the electrolyte, and sample extraction. Ethanol, acetonitrile, sulfuric acid, water at 50 degrees C or at room temperature were tested as sample buffers (SB). Water at room temperature yielded the best overall results and was chosen for further validation. The extraction time was checked and could be shortened to less than 1 min. Also, sample preparation was simplified to pipet 12 microl of milk into 1 ml of water containing 20 ppm of tartaric acid as an internal standard. The linearity of the method was excellent (R2 > 0.999) with CV values of response factors <3%. The detection limits for phosphate and citrate were 5.1 and 2.4 nM, respectively. The accuracy of the method was calculated for each compound (103.2 and 100.3%). In addition, citrate and phosphate content of several commercial milk samples were analyzed by this method, and the results deviated less than 5% from values obtained when analyzing the samples by official methods. To study the versatility of the technique, other dairy productssuch as cream cheese, yogurt, or Cheddar cheese were analyzed and accuracy was similar to milk in all products tested. The procedure is rapid and offers a very fast and simple sample preparation. Once the sample has arrived at the laboratory, less than 5 min (including handling, preparation, running, integration, and quantification) are necessary to determine the concentration of citric acid and inorganic phosphate. Because of the speed and accuracy of this method, it is promising as an analytical quantitative testing technique.

  8. Real-time PCR detection of Plasmodium directly from whole blood and filter paper samples

    PubMed Central

    2011-01-01

    Background Real-time PCR is a sensitive and specific method for the analysis of Plasmodium DNA. However, prior purification of genomic DNA from blood is necessary since PCR inhibitors and quenching of fluorophores from blood prevent efficient amplification and detection of PCR products. Methods Reagents designed to specifically overcome PCR inhibition and quenching of fluorescence were evaluated for real-time PCR amplification of Plasmodium DNA directly from blood. Whole blood from clinical samples and dried blood spots collected in the field in Colombia were tested. Results Amplification and fluorescence detection by real-time PCR were optimal with 40× SYBR® Green dye and 5% blood volume in the PCR reaction. Plasmodium DNA was detected directly from both whole blood and dried blood spots from clinical samples. The sensitivity and specificity ranged from 93-100% compared with PCR performed on purified Plasmodium DNA. Conclusions The methodology described facilitates high-throughput testing of blood samples collected in the field by fluorescence-based real-time PCR. This method can be applied to a broad range of clinical studies with the advantages of immediate sample testing, lower experimental costs and time-savings. PMID:21851640

  9. Efficient IDUA Gene Mutation Detection with Combined Use of dHPLC and Dried Blood Samples

    PubMed Central

    Duarte, Ana Joana; Vieira, Luis

    2013-01-01

    Objectives. Development of a simple mutation directed method in order to allow lowering the cost of mutation testing using an easily obtainable biological material. Assessment of the feasibility of such method was tested using a GC-rich amplicon. Design and Methods. A method of denaturing high-performance liquid chromatography (dHPLC) was improved and implemented as a technique for the detection of variants in exon 9 of the IDUA gene. The optimized method was tested in 500 genomic DNA samples obtained from dried blood spots (DBS). Results. With this dHPLC approach it was possible to detect different variants, including the common p.Trp402Ter mutation in the IDUA gene. The high GC content did not interfere with the resolution and reliability of this technique, and discrimination of G-C transversions was also achieved. Conclusion. This PCR-based dHPLC method is proved to be a rapid, a sensitive, and an excellent option for screening numerous samples obtained from DBS. Furthermore, it resulted in the consistent detection of clearly distinguishable profiles of the common p.Trp402Ter IDUA mutation with an advantageous balance of cost and technical requirements. PMID:27335677

  10. Metadynamics for training neural network model chemistries: A competitive assessment

    NASA Astrophysics Data System (ADS)

    Herr, John E.; Yao, Kun; McIntyre, Ryker; Toth, David W.; Parkhill, John

    2018-06-01

    Neural network model chemistries (NNMCs) promise to facilitate the accurate exploration of chemical space and simulation of large reactive systems. One important path to improving these models is to add layers of physical detail, especially long-range forces. At short range, however, these models are data driven and data limited. Little is systematically known about how data should be sampled, and "test data" chosen randomly from some sampling techniques can provide poor information about generality. If the sampling method is narrow, "test error" can appear encouragingly tiny while the model fails catastrophically elsewhere. In this manuscript, we competitively evaluate two common sampling methods: molecular dynamics (MD), normal-mode sampling, and one uncommon alternative, Metadynamics (MetaMD), for preparing training geometries. We show that MD is an inefficient sampling method in the sense that additional samples do not improve generality. We also show that MetaMD is easily implemented in any NNMC software package with cost that scales linearly with the number of atoms in a sample molecule. MetaMD is a black-box way to ensure samples always reach out to new regions of chemical space, while remaining relevant to chemistry near kbT. It is a cheap tool to address the issue of generalization.

  11. Validation of the ANSR Salmonella method for detection of Salmonella spp. in selected foods and environmental samples.

    PubMed

    Mozola, Mark; Norton, Paul; Alles, Susan; Gray, R Lucas; Tolan, Jerry; Caballero, Oscar; Pinkava, Lisa; Hosking, Edan; Luplow, Karen; Rice, Jennifer

    2013-01-01

    ANSR Salmonella is a new molecular diagnostic assay for detection of Salmonella spp. in foods and environmental samples. The test is based on the nicking enzyme amplification reaction (NEAR) isothermal nucleic acid amplification technology. The assay platform features simple instrumentation, minimal labor, and, following a single-step 10-24 h enrichment (depending on sample type), an extremely short assay time of 30 min, including sample preparation. Detection is real-time using fluorescent molecular beacon probes. Inclusivity testing was performed using a panel of 113 strains of S. enterica and S. bongori, representing 109 serovars and all genetic subgroups. With the single exception of the rare serovar S. Weslaco, all serovars and genetic subgroups were detected. Exclusivity testing of 38 non-salmonellae, mostly Enterobacteriaceae, yielded no evidence of cross-reactivity. In comparative testing of chicken carcass rinse, raw ground turkey, raw ground beef, hot dogs, and oat cereal, there were no statistically significant differences in the number of positive results obtained with the ANSR and the U.S. Department of Agriculture-Food Safety and Inspection Service or U.S. Food and Drug Administration/Bacteriological Analytical Manual reference culture methods. In testing of swab or sponge samples from five different environmental surfaces, four trials showed no statistically significant differences in the number of positive results by the ANSR and the U.S. Food and Drug Administration/ Bacteriological Analytical Manual reference methods; in the trial with stainless steel surface, there were significantly more positive results by the ANSR method. Ruggedness experiments showed a high degree of assay robustness when deviations in reagent volumes and incubation times were introduced.

  12. Reflexion on linear regression trip production modelling method for ensuring good model quality

    NASA Astrophysics Data System (ADS)

    Suprayitno, Hitapriya; Ratnasari, Vita

    2017-11-01

    Transport Modelling is important. For certain cases, the conventional model still has to be used, in which having a good trip production model is capital. A good model can only be obtained from a good sample. Two of the basic principles of a good sampling is having a sample capable to represent the population characteristics and capable to produce an acceptable error at a certain confidence level. It seems that this principle is not yet quite understood and used in trip production modeling. Therefore, investigating the Trip Production Modelling practice in Indonesia and try to formulate a better modeling method for ensuring the Model Quality is necessary. This research result is presented as follows. Statistics knows a method to calculate span of prediction value at a certain confidence level for linear regression, which is called Confidence Interval of Predicted Value. The common modeling practice uses R2 as the principal quality measure, the sampling practice varies and not always conform to the sampling principles. An experiment indicates that small sample is already capable to give excellent R2 value and sample composition can significantly change the model. Hence, good R2 value, in fact, does not always mean good model quality. These lead to three basic ideas for ensuring good model quality, i.e. reformulating quality measure, calculation procedure, and sampling method. A quality measure is defined as having a good R2 value and a good Confidence Interval of Predicted Value. Calculation procedure must incorporate statistical calculation method and appropriate statistical tests needed. A good sampling method must incorporate random well distributed stratified sampling with a certain minimum number of samples. These three ideas need to be more developed and tested.

  13. Near-Native Protein Loop Sampling Using Nonparametric Density Estimation Accommodating Sparcity

    PubMed Central

    Day, Ryan; Lennox, Kristin P.; Sukhanov, Paul; Dahl, David B.; Vannucci, Marina; Tsai, Jerry

    2011-01-01

    Unlike the core structural elements of a protein like regular secondary structure, template based modeling (TBM) has difficulty with loop regions due to their variability in sequence and structure as well as the sparse sampling from a limited number of homologous templates. We present a novel, knowledge-based method for loop sampling that leverages homologous torsion angle information to estimate a continuous joint backbone dihedral angle density at each loop position. The φ,ψ distributions are estimated via a Dirichlet process mixture of hidden Markov models (DPM-HMM). Models are quickly generated based on samples from these distributions and were enriched using an end-to-end distance filter. The performance of the DPM-HMM method was evaluated against a diverse test set in a leave-one-out approach. Candidates as low as 0.45 Å RMSD and with a worst case of 3.66 Å were produced. For the canonical loops like the immunoglobulin complementarity-determining regions (mean RMSD <2.0 Å), the DPM-HMM method performs as well or better than the best templates, demonstrating that our automated method recaptures these canonical loops without inclusion of any IgG specific terms or manual intervention. In cases with poor or few good templates (mean RMSD >7.0 Å), this sampling method produces a population of loop structures to around 3.66 Å for loops up to 17 residues. In a direct test of sampling to the Loopy algorithm, our method demonstrates the ability to sample nearer native structures for both the canonical CDRH1 and non-canonical CDRH3 loops. Lastly, in the realistic test conditions of the CASP9 experiment, successful application of DPM-HMM for 90 loops from 45 TBM targets shows the general applicability of our sampling method in loop modeling problem. These results demonstrate that our DPM-HMM produces an advantage by consistently sampling near native loop structure. The software used in this analysis is available for download at http://www.stat.tamu.edu/~dahl/software/cortorgles/. PMID:22028638

  14. Methods for the field evaluation of quantitative G6PD diagnostics: a review.

    PubMed

    Ley, Benedikt; Bancone, Germana; von Seidlein, Lorenz; Thriemer, Kamala; Richards, Jack S; Domingo, Gonzalo J; Price, Ric N

    2017-09-11

    Individuals with glucose-6-phosphate dehydrogenase (G6PD) deficiency are at risk of severe haemolysis following the administration of 8-aminoquinoline compounds. Primaquine is the only widely available 8-aminoquinoline for the radical cure of Plasmodium vivax. Tafenoquine is under development with the potential to simplify treatment regimens, but point-of-care (PoC) tests will be needed to provide quantitative measurement of G6PD activity prior to its administration. There is currently a lack of appropriate G6PD PoC tests, but a number of new tests are in development and are likely to enter the market in the coming years. As these are implemented, they will need to be validated in field studies. This article outlines the technical details for the field evaluation of novel quantitative G6PD diagnostics such as sample handling, reference testing and statistical analysis. Field evaluation is based on the comparison of paired samples, including one sample tested by the new assay at point of care and one sample tested by the gold-standard reference method, UV spectrophotometry in an established laboratory. Samples can be collected as capillary or venous blood; the existing literature suggests that potential differences in capillary or venous blood are unlikely to affect results substantially. The collection and storage of samples is critical to ensure preservation of enzyme activity, it is recommended that samples are stored at 4 °C and testing occurs within 4 days of collection. Test results can be visually presented as scatter plot, Bland-Altman plot, and a histogram of the G6PD activity distribution of the study population. Calculating the adjusted male median allows categorizing results according to G6PD activity to calculate standard performance indicators and to perform receiver operating characteristic (ROC) analysis.

  15. SU-E-T-769: T-Test Based Prior Error Estimate and Stopping Criterion for Monte Carlo Dose Calculation in Proton Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hong, X; Gao, H; Schuemann, J

    2015-06-15

    Purpose: The Monte Carlo (MC) method is a gold standard for dose calculation in radiotherapy. However, it is not a priori clear how many particles need to be simulated to achieve a given dose accuracy. Prior error estimate and stopping criterion are not well established for MC. This work aims to fill this gap. Methods: Due to the statistical nature of MC, our approach is based on one-sample t-test. We design the prior error estimate method based on the t-test, and then use this t-test based error estimate for developing a simulation stopping criterion. The three major components are asmore » follows.First, the source particles are randomized in energy, space and angle, so that the dose deposition from a particle to the voxel is independent and identically distributed (i.i.d.).Second, a sample under consideration in the t-test is the mean value of dose deposition to the voxel by sufficiently large number of source particles. Then according to central limit theorem, the sample as the mean value of i.i.d. variables is normally distributed with the expectation equal to the true deposited dose.Third, the t-test is performed with the null hypothesis that the difference between sample expectation (the same as true deposited dose) and on-the-fly calculated mean sample dose from MC is larger than a given error threshold, in addition to which users have the freedom to specify confidence probability and region of interest in the t-test based stopping criterion. Results: The method is validated for proton dose calculation. The difference between the MC Result based on the t-test prior error estimate and the statistical Result by repeating numerous MC simulations is within 1%. Conclusion: The t-test based prior error estimate and stopping criterion are developed for MC and validated for proton dose calculation. Xiang Hong and Hao Gao were partially supported by the NSFC (#11405105), the 973 Program (#2015CB856000) and the Shanghai Pujiang Talent Program (#14PJ1404500)« less

  16. Hippocampus Segmentation Based on Local Linear Mapping

    PubMed Central

    Pang, Shumao; Jiang, Jun; Lu, Zhentai; Li, Xueli; Yang, Wei; Huang, Meiyan; Zhang, Yu; Feng, Yanqiu; Huang, Wenhua; Feng, Qianjin

    2017-01-01

    We propose local linear mapping (LLM), a novel fusion framework for distance field (DF) to perform automatic hippocampus segmentation. A k-means cluster method is propose for constructing magnetic resonance (MR) and DF dictionaries. In LLM, we assume that the MR and DF samples are located on two nonlinear manifolds and the mapping from the MR manifold to the DF manifold is differentiable and locally linear. We combine the MR dictionary using local linear representation to present the test sample, and combine the DF dictionary using the corresponding coefficients derived from local linear representation procedure to predict the DF of the test sample. We then merge the overlapped predicted DF patch to obtain the DF value of each point in the test image via a confidence-based weighted average method. This approach enabled us to estimate the label of the test image according to the predicted DF. The proposed method was evaluated on brain images of 35 subjects obtained from SATA dataset. Results indicate the effectiveness of the proposed method, which yields mean Dice similarity coefficients of 0.8697, 0.8770 and 0.8734 for the left, right and bi-lateral hippocampus, respectively. PMID:28368016

  17. Hippocampus Segmentation Based on Local Linear Mapping.

    PubMed

    Pang, Shumao; Jiang, Jun; Lu, Zhentai; Li, Xueli; Yang, Wei; Huang, Meiyan; Zhang, Yu; Feng, Yanqiu; Huang, Wenhua; Feng, Qianjin

    2017-04-03

    We propose local linear mapping (LLM), a novel fusion framework for distance field (DF) to perform automatic hippocampus segmentation. A k-means cluster method is propose for constructing magnetic resonance (MR) and DF dictionaries. In LLM, we assume that the MR and DF samples are located on two nonlinear manifolds and the mapping from the MR manifold to the DF manifold is differentiable and locally linear. We combine the MR dictionary using local linear representation to present the test sample, and combine the DF dictionary using the corresponding coefficients derived from local linear representation procedure to predict the DF of the test sample. We then merge the overlapped predicted DF patch to obtain the DF value of each point in the test image via a confidence-based weighted average method. This approach enabled us to estimate the label of the test image according to the predicted DF. The proposed method was evaluated on brain images of 35 subjects obtained from SATA dataset. Results indicate the effectiveness of the proposed method, which yields mean Dice similarity coefficients of 0.8697, 0.8770 and 0.8734 for the left, right and bi-lateral hippocampus, respectively.

  18. Hippocampus Segmentation Based on Local Linear Mapping

    NASA Astrophysics Data System (ADS)

    Pang, Shumao; Jiang, Jun; Lu, Zhentai; Li, Xueli; Yang, Wei; Huang, Meiyan; Zhang, Yu; Feng, Yanqiu; Huang, Wenhua; Feng, Qianjin

    2017-04-01

    We propose local linear mapping (LLM), a novel fusion framework for distance field (DF) to perform automatic hippocampus segmentation. A k-means cluster method is propose for constructing magnetic resonance (MR) and DF dictionaries. In LLM, we assume that the MR and DF samples are located on two nonlinear manifolds and the mapping from the MR manifold to the DF manifold is differentiable and locally linear. We combine the MR dictionary using local linear representation to present the test sample, and combine the DF dictionary using the corresponding coefficients derived from local linear representation procedure to predict the DF of the test sample. We then merge the overlapped predicted DF patch to obtain the DF value of each point in the test image via a confidence-based weighted average method. This approach enabled us to estimate the label of the test image according to the predicted DF. The proposed method was evaluated on brain images of 35 subjects obtained from SATA dataset. Results indicate the effectiveness of the proposed method, which yields mean Dice similarity coefficients of 0.8697, 0.8770 and 0.8734 for the left, right and bi-lateral hippocampus, respectively.

  19. [A Simultaneous Determination Method with Acetonitrile-n-Hexane Partitioning and Solid-Phase Extraction for Pesticide Residues in Livestock and Marine Products by GC-MS].

    PubMed

    Yoshizaki, Mayuko; Kobayashi, Yukari; Shimizu, Masanori; Maruyama, Kouichi

    2015-01-01

    A simultaneous determination method was examined for 312 pesticides (including isomers) in muscle of livestock and marine products by GC-MS. The pesticide residues extracted from samples with acetone and n-hexane were purified by acetonitrile-n-hexane partitioning, and C18 and SAX/PSA solid-phase extraction without using GPC. Matrix components such as cholesterol were effectively removed. In recovery tests performed by this method using pork, beef, chicken and shrimp, 237-257 pesticides showed recoveries within the range of 70-120% in each sample. Validity was confirmed for 214 of the target pesticides by means of a validation test using pork. In comparison with the Japanese official method using GPC, the treatment time of samples and the quantity of solvent were reduced substantially.

  20. Linear sampling method applied to non destructive testing of an elastic waveguide: theory, numerics and experiments

    NASA Astrophysics Data System (ADS)

    Baronian, Vahan; Bourgeois, Laurent; Chapuis, Bastien; Recoquillay, Arnaud

    2018-07-01

    This paper presents an application of the linear sampling method to ultrasonic non destructive testing of an elastic waveguide. In particular, the NDT context implies that both the solicitations and the measurements are located on the surface of the waveguide and are given in the time domain. Our strategy consists in using a modal formulation of the linear sampling method at multiple frequencies, such modal formulation being justified theoretically in Bourgeois et al (2011 Inverse Problems 27 055001) for rigid obstacles and in Bourgeois and Lunéville (2013 Inverse Problems 29 025017) for cracks. Our strategy requires the inversion of some emission and reception matrices which deserve some special attention due to potential ill-conditioning. The feasibility of our method is proved with the help of artificial data as well as real data.

  1. Evaluation of Modification of the 3M™ Molecular Detection Assay (MDA) Salmonella Method (2013.09) for the Detection of Salmonella in Selected Foods: Collaborative Study.

    PubMed

    Bird, Patrick; Fisher, Kiel; Boyle, Megan; Huffman, Travis; Benzinger, M Joseph; Bedinghaus, Paige; Flannery, Jonathon; Crowley, Erin; Agin, James; Goins, David; Benesh, DeAnn; David, John

    2014-01-01

    The 3M(™) Molecular Detection Assay (MDA) Salmonella utilizes isothermal amplification of nucleic acid sequences with high specificity, efficiency, rapidity and bioluminescence to detect amplification of Salmonella spp. in food, food-related, and environmental samples after enrichment. A method modification and matrix extension study of the previously approved AOAC Official Method(SM) 2013.09 was conducted, and approval of the modification was received on March 20, 2014. Using an unpaired study design in a multilaboratory collaborative study, the 3M MDA Salmonella method was compared to the U.S. Department of Agriculture/Food Safety and Inspection Service (USDA/FSIS) Microbiology Laboratory Guidebook (MLG) 4.05 (2011), Isolation and Identification of Salmonella from Meat, Poultry, Pasteurized Egg, and Catfish Products for raw ground beef and the U.S. Food and Drug Administration (FDA)/Bacteriological Analytical Manual (BAM) Chapter 5, Salmonella reference method for wet dog food following the current AOAC guidelines. A total of 20 laboratories participated. For the 3M MDA Salmonella method, raw ground beef was analyzed using 25 g test portions, and wet dog food was analyzed using 375 g test portions. For the reference methods, 25 g test portions of each matrix were analyzed. Each matrix was artificially contaminated with Salmonella at three inoculation levels: an uninoculated control level (0 CFU/test portion), a low inoculum level (0.2-2 CFU/test portion), and a high inoculum level (2-5 CFU/test portion). In this study, 1512 unpaired replicate samples were analyzed. Statistical analysis was conducted according to the probability of detection (POD). For the low-level raw ground beef test portions, the following dLPOD (difference between the LPODs of the reference and candidate method) values with 95% confidence intervals were obtained: -0.01 (-0.14, +0.12). For the low-level wet dog food test portions, the following dLPOD with 95% confidence intervals were obtained: -0.04 (-0.16, +0.09). No significant differences were observed in the number of positive samples detected by the 3M MDA Salmonella method versus either the USDA/FSIS-MLG or FDA/BAM methods.

  2. Visually testing the dynamic character of a blazed-angle adjustable grating by digital holographic microscopy.

    PubMed

    Qin, Chuan; Zhao, Jianlin; Di, Jianglei; Wang, Le; Yu, Yiting; Yuan, Weizheng

    2009-02-10

    We employed digital holographic microscopy to visually test microoptoelectromechanical systems (MOEMS). The sample is a blazed-angle adjustable grating. Considering the periodic structure of the sample, a local area unwrapping method based on a binary template was adopted to demodulate the fringes obtained by referring to a reference hologram. A series of holograms at different deformation states due to different drive voltages were captured to analyze the dynamic character of the MOEMS, and the uniformity of different microcantilever beams was also inspected. The results show this testing method is effective for a periodic structure.

  3. Bacteria detection instrument and method

    NASA Technical Reports Server (NTRS)

    Renner, W.; Fealey, R. D. (Inventor)

    1972-01-01

    A method and apparatus for screening a sample fluid for bacterial presence are disclosed wherein the fluid sample is mixed with culture media of sufficient quantity to permit bacterial growth in order to obtain a test solution. The concentration of oxygen dissolved in the test solution is then monitored using the potential difference between a reference electrode and a noble metal electrode which are in contact with the test solution. The change in oxygen concentration which occurs during a period of time as indicated by the electrode potential difference is compared with a detection criterion which exceeds the change which would occur absent bacteria.

  4. PubMed Central

    Miezan, T.; Doua, F.; Cattand, P.; de Raadt, P.

    1991-01-01

    The Testryp CATT was performed on dried blood samples on filter-paper and on diluted blood using a microtechnique. This method was applied to both sample collection techniques and was evaluated in parallel with the classical Testryp CATT on whole blood, as described in the instructions provided with the reagents by the manufacturer. A total of 2087 people were tested; 453 samples were tested in the laboratory and 1634 during a field survey in 5 villages of a trypanosomiasis focus in Daloa, Côte d'Ivoire. This study has demonstrated that the Testryp CATT micromethod on either type of sample collection gives results comparable to the Testryp CATT on whole blood. The collection of dried blood samples on filter-paper can be performed by non-specialized staff in trypanosomiasis control programmes of the national health services. In addition, a flask of CATT reagent will allow testing of 6 times more people by the micromethod than by the classical whole-blood method. The micromethod is suitable in the implementation of programmes for the serological surveillance of populations at risk. PMID:1959162

  5. Establishment of a nested-ASP-PCR method to determine the clarithromycin resistance of Helicobacter pylori

    PubMed Central

    Luo, Xiao-Feng; Jiao, Jian-Hua; Zhang, Wen-Yue; Pu, Han-Ming; Qu, Bao-Jin; Yang, Bing-Ya; Hou, Min; Ji, Min-Jun

    2016-01-01

    AIM: To investigate clarithromycin resistance positions 2142, 2143 and 2144 of the 23SrRNA gene in Helicobacter pylori (H. pylori) by nested-allele specific primer-polymerase chain reaction (nested-ASP-PCR). METHODS: The gastric tissue and saliva samples from 99 patients with positive results of the rapid urease test (RUT) were collected. The nested-ASP-PCR method was carried out with the external primers and inner allele-specific primers corresponding to the reference strain and clinical strains. Thirty gastric tissue and saliva samples were tested to determine the sensitivity of nested-ASP-PCR and ASP-PCR methods. Then, clarithromycin resistance was detected for 99 clinical samples by using different methods, including nested-ASP-PCR, bacterial culture and disk diffusion. RESULTS: The nested-ASP-PCR method was successfully established to test the resistance mutation points 2142, 2143 and 2144 of the 23SrRNA gene of H. pylori. Among 30 samples of gastric tissue and saliva, the H. pylori detection rate of nested-ASP-PCR was 90% and 83.33%, while the detection rate of ASP-PCR was just 63% and 56.67%. Especially in the saliva samples, nested-ASP-PCR showed much higher sensitivity in H. pylori detection and resistance mutation rates than ASP-PCR. In the 99 RUT-positive gastric tissue and saliva samples, the H. pylori-positive detection rate by nested-ASP-PCR was 87 (87.88%) and 67 (67.68%), in which there were 30 wild-type and 57 mutated strains in gastric tissue and 22 wild-type and 45 mutated strains in saliva. Genotype analysis showed that three-points mixed mutations were quite common, but different resistant strains were present in gastric mucosa and saliva. Compared to the high sensitivity shown by nested-ASP-PCR, the positive detection of bacterial culture with gastric tissue samples was 50 cases, in which only 26 drug-resistant strains were found through analyzing minimum inhibitory zone of clarithromycin. CONCLUSION: The nested-ASP-PCR assay showed higher detection sensitivity than ASP-PCR and drug sensitivity testing, which could be performed to evaluate clarithromycin resistance of H. pylori. PMID:27433095

  6. Effectiveness of Cool Roof Coatings with Ceramic Particles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brehob, Ellen G; Desjarlais, Andre Omer; Atchley, Jerald Allen

    2011-01-01

    Liquid applied coatings promoted as cool roof coatings, including several with ceramic particles, were tested at Oak Ridge National Laboratory (ORNL), Oak Ridge, Tenn., for the purpose of quantifying their thermal performances. Solar reflectance measurements were made for new samples and aged samples using a portable reflectometer (ASTM C1549, Standard Test Method for Determination of Solar Reflectance Near Ambient Temperature Using a Portable Solar Reflectometer) and for new samples using the integrating spheres method (ASTM E903, Standard Test Method for Solar Absorptance, Reflectance, and Transmittance of Materials Using Integrating Spheres). Thermal emittance was measured for the new samples using amore » portable emissometer (ASTM C1371, Standard Test Method for Determination of Emittance of Materials Near Room 1 Proceedings of the 2011 International Roofing Symposium Temperature Using Portable Emissometers). Thermal conductivity of the coatings was measured using a FOX 304 heat flow meter (ASTM C518, Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus). The surface properties of the cool roof coatings had higher solar reflectance than the reference black and white material, but there were no significant differences among coatings with and without ceramics. The coatings were applied to EPDM (ethylene propylene diene monomer) membranes and installed on the Roof Thermal Research Apparatus (RTRA), an instrumented facility at ORNL for testing roofs. Roof temperatures and heat flux through the roof were obtained for a year of exposure in east Tennessee. The field tests showed significant reduction in cooling required compared with the black reference roof (~80 percent) and a modest reduction in cooling compared with the white reference roof (~33 percent). The coating material with the highest solar reflectivity (no ceramic particles) demonstrated the best overall thermal performance (combination of reducing the cooling load cost and not incurring a large heating penalty cost) and suggests solar reflectivity is the significant characteristic for selecting cool roof coatings.« less

  7. [Intestinal parasitic diseases in children].

    PubMed

    Mare, Anca; Man, A; Toma, Felicia; Székely, Edit; Lôrinczi, Lilla; Sipoş, Anca

    2007-01-01

    To compare the incidence of intestinal parasitosis between children with residence in urban and rural areas: to compare the efficacy of parasitologic diagnostic methods. In our study we included two lots of children. The first lot consisted in 74 children from rural areas from which we collected 44 samples of feces and 55 samples for the "Scotch tape" test. The second lot consisted in 214 children from urban areas from which we collected 44 samples of feces. We examined each sample of feces by three different methods. The study was performed between April to June 2006. The incidence of intestinal parasitosis increases in children from urban areas towards rural areas, and in children between 5 and 10 years. Ascariasis is the most frequent disease in both urban and rural areas. By examination of each fecal sample by three different methods, the number of positive cases increased. The residence in rural areas and age between 5 to 10 years are risk factors for intestinal parasitosis. The "Scotch tape" test was more efficient in Enterobius vermicularis infection than the methods performed from feces. We recommend using at the same time three diagnostic methods for feces examination to improve the diagnostic sensibility.

  8. Attitudes towards HIV testing via home-sampling kits ordered online (RUClear pilots 2011-12).

    PubMed

    Ahmed-Little, Y; Bothra, V; Cordwell, D; Freeman Powell, D; Ellis, D; Klapper, P; Scanlon, S; Higgins, S; Vivancos, R

    2016-09-01

    The burden of disease relating to undiagnosed HIV infection is significant in the UK. BHIVA (British HIV Association) recommends population screening in high prevalence areas, expanding outside traditional antenatal/GUM settings. RUClear 2011-12 piloted expanding HIV testing outside traditional settings using home-sampling kits (dry-blood-spot testing) ordered online. Greater Manchester residents (≥age 16) could request testing via an established, online chlamydia testing service (www.ruclear.co.uk). Participant attitudes towards this new service were assessed. Qualitative methods (thematic analysis) were used to analyse free-text data submitted by participants via hard copy questionnaires issued in all testing kits. 79.9% (2447/3062) participants completed questionnaires, of which 30.9% (756/2447) provided free-text data. Participants overwhelmingly supported the service, valuing particularly accessibility and convenience, allowing individuals to order tests any time of day and self-sample comfortably at home; avoiding the invasive nature of venipuncture and avoiding the need for face-to-face interaction with health services. The pilot was also clinically and cost-effective. Testing via home-sampling kits ordered online (dry-blood-spot testing) was felt to be an acceptable and convenient method for accessing a HIV test. Many individuals undertook HIV testing where they would otherwise not have been tested at all. Expansion of similar services may increase the uptake of HIV testing. © The Author 2015. Published by Oxford University Press on behalf of Faculty of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  9. MRI-determined liver proton density fat fraction, with MRS validation: Comparison of regions of interest sampling methods in patients with type 2 diabetes.

    PubMed

    Vu, Kim-Nhien; Gilbert, Guillaume; Chalut, Marianne; Chagnon, Miguel; Chartrand, Gabriel; Tang, An

    2016-05-01

    To assess the agreement between published magnetic resonance imaging (MRI)-based regions of interest (ROI) sampling methods using liver mean proton density fat fraction (PDFF) as the reference standard. This retrospective, internal review board-approved study was conducted in 35 patients with type 2 diabetes. Liver PDFF was measured by magnetic resonance spectroscopy (MRS) using a stimulated-echo acquisition mode sequence and MRI using a multiecho spoiled gradient-recalled echo sequence at 3.0T. ROI sampling methods reported in the literature were reproduced and liver mean PDFF obtained by whole-liver segmentation was used as the reference standard. Intraclass correlation coefficients (ICCs), Bland-Altman analysis, repeated-measures analysis of variance (ANOVA), and paired t-tests were performed. ICC between MRS and MRI-PDFF was 0.916. Bland-Altman analysis showed excellent intermethod agreement with a bias of -1.5 ± 2.8%. The repeated-measures ANOVA found no systematic variation of PDFF among the nine liver segments. The correlation between liver mean PDFF and ROI sampling methods was very good to excellent (0.873 to 0.975). Paired t-tests revealed significant differences (P < 0.05) with ROI sampling methods that exclusively or predominantly sampled the right lobe. Significant correlations with mean PDFF were found with sampling methods that included higher number of segments, total area equal or larger than 5 cm(2) , or sampled both lobes (P = 0.001, 0.023, and 0.002, respectively). MRI-PDFF quantification methods should sample each liver segment in both lobes and include a total surface area equal or larger than 5 cm(2) to provide a close estimate of the liver mean PDFF. © 2015 Wiley Periodicals, Inc.

  10. Solubility testing of actinides on breathing-zone and area air samples

    NASA Astrophysics Data System (ADS)

    Metzger, Robert Lawrence

    The solubility of inhaled radionuclides in the human lung is an important characteristic of the compounds needed to perform internal dosimetry assessments for exposed workers. A solubility testing method for uranium and several common actinides has been developed with sufficient sensitivity to allow profiles to be determined from routine breathing zone and area air samples in the workplace. Air samples are covered with a clean filter to form a filter-sample-filter sandwich which is immersed in an extracellular lung serum simulant solution. The sample is moved to a fresh beaker of the lung fluid simulant each day for one week, and then weekly until the end of the 28 day test period. The soak solutions are wet ashed with nitric acid and hydrogen peroxide to destroy the organic components of the lung simulant solution prior to extraction of the nuclides of interest directly into an extractive scintillator for subsequent counting on a Photon-Electron Rejecting Alpha Liquid Scintillation (PERALSsp°ler ) spectrometer. Solvent extraction methods utilizing the extractive scintillators have been developed for the isotopes of uranium, plutonium, and curium. The procedures normally produce an isotopic recovery greater than 95% and have been used to develop solubility profiles from air samples with 40 pCi or less of Usb3Osb8. This makes it possible to characterize solubility profiles in every section of operating facilities where airborne nuclides are found using common breathing zone air samples. The new method was evaluated by analyzing uranium compounds from two uranium mills whose product had been previously analyzed by in vitro solubility testing in the laboratory and in vivo solubility testing in rodents. The new technique compared well with the in vivo rodent solubility profiles. The method was then used to evaluate the solubility profiles in all process sections of an operating in situ uranium plant using breathing zone and area air samples collected during routine plant operations. The solubility profiles developed from this work showed excellent agreement with the results of the worker urine bioassay program at the plant and identified a significant error in existing internal dose assessments at this facility.

  11. Use of Fourier-transform infrared spectroscopy to quantify immunoglobulin G concentrations in alpaca serum.

    PubMed

    Burns, J; Hou, S; Riley, C B; Shaw, R A; Jewett, N; McClure, J T

    2014-01-01

    Rapid, economical, and quantitative assays for measurement of camelid serum immunoglobulin G (IgG) are limited. In camelids, failure of transfer of maternal immunoglobulins has a reported prevalence of up to 20.5%. An accurate method for quantifying serum IgG concentrations is required. To develop an infrared spectroscopy-based assay for measurement of alpaca serum IgG and compare its performance to the reference standard radial immunodiffusion (RID) assay. One hundred and seventy-five privately owned, healthy alpacas. Eighty-two serum samples were collected as convenience samples during routine herd visits whereas 93 samples were recruited from a separate study. Serum IgG concentrations were determined by RID assays and midinfrared spectra were collected for each sample. Fifty samples were set aside as the test set and the remaining 125 training samples were employed to build a calibration model using partial least squares (PLS) regression with Monte Carlo cross validation to determine the optimum number of PLS factors. The predictive performance of the calibration model was evaluated by the test set. Correlation coefficients for the IR-based assay were 0.93 and 0.87, respectively, for the entire data set and test set. Sensitivity in the diagnosis of failure of transfer of passive immunity (FTPI) ([IgG] <1,000 mg/dL) was 71.4% and specificity was 100% for the IR-based method (test set) as gauged relative to the RID reference method assay. This study indicated that infrared spectroscopy, in combination with chemometrics, is an effective method for measurement of IgG in alpaca serum. Copyright © 2014 by the American College of Veterinary Internal Medicine.

  12. Determination of cathinones and other stimulant, psychedelic, and dissociative designer drugs in real hair samples.

    PubMed

    Salomone, Alberto; Gazzilli, Giulia; Di Corcia, Daniele; Gerace, Enrico; Vincenti, Marco

    2016-03-01

    The detection of new psychoactive substances (NPS) in hair proved to provide insight into their current diffusion among the population and the social characteristics of these synthetic drugs' users. Therefore, a UHPLC-MS/MS method was developed in order to determine 31 stimulant and psychedelic substituted phenethylamines, and dissociative drugs in hair samples. The method proved to be simple, fast, specific, and sensitive. The absence of matrix interferents, together with excellent repeatability of both retention times and relative abundances of diagnostic transitions, allowed the correct identification of all analytes tested. The method showed optimal linearity in the interval 10-1000 pg/mg, with correlation coefficient values varying between 0.9981 and 0.9997. Quantitation limits ranged from 1.8 pg/mg for 4-methoxyphencyclidine (4-MeO-PCP) up to 35 pg/mg for 6-(2-aminopropyl)benzofuran (6-APB). The method was applied to (i) 23 real samples taken from proven MDMA and ketamine abusers and (ii) 54 real hair samples which had been previously tested negative during regular drug screening in driver's license recovery. Six samples tested positive for at least one target analyte. Methoxetamine (MXE) was found in three cases (range of concentration 7.7-27 pg/mg); mephedrone (4-MMC) was found in two cases (50-59 pg/mg) while one sample tested positive for methylone at 28 pg/mg. Other positive findings included 4-methylethcathinone (4-MEC), alpha-pyrrolidinovalerophenone (α-PVP), 4-fluoroamphetamine (4-FA), 3,4-methylenedioxypyrovalerone (MDPV), and diphenidine. The present study confirms the increasing diffusion of new designer drugs with enhanced stimulant activity among the target population of poly-abuse consumers.

  13. The predictive validity of selection for entry into postgraduate training in general practice: evidence from three longitudinal studies.

    PubMed

    Patterson, Fiona; Lievens, Filip; Kerrin, Máire; Munro, Neil; Irish, Bill

    2013-11-01

    The selection methodology for UK general practice is designed to accommodate several thousand applicants per year and targets six core attributes identified in a multi-method job-analysis study To evaluate the predictive validity of selection methods for entry into postgraduate training, comprising a clinical problem-solving test, a situational judgement test, and a selection centre. A three-part longitudinal predictive validity study of selection into training for UK general practice. In sample 1, participants were junior doctors applying for training in general practice (n = 6824). In sample 2, participants were GP registrars 1 year into training (n = 196). In sample 3, participants were GP registrars sitting the licensing examination after 3 years, at the end of training (n = 2292). The outcome measures include: assessor ratings of performance in a selection centre comprising job simulation exercises (sample 1); supervisor ratings of trainee job performance 1 year into training (sample 2); and licensing examination results, including an applied knowledge examination and a 12-station clinical skills objective structured clinical examination (OSCE; sample 3). Performance ratings at selection predicted subsequent supervisor ratings of job performance 1 year later. Selection results also significantly predicted performance on both the clinical skills OSCE and applied knowledge examination for licensing at the end of training. In combination, these longitudinal findings provide good evidence of the predictive validity of the selection methods, and are the first reported for entry into postgraduate training. Results show that the best predictor of work performance and training outcomes is a combination of a clinical problem-solving test, a situational judgement test, and a selection centre. Implications for selection methods for all postgraduate specialties are considered.

  14. Nonclinical dose formulation analysis method validation and sample analysis.

    PubMed

    Whitmire, Monica Lee; Bryan, Peter; Henry, Teresa R; Holbrook, John; Lehmann, Paul; Mollitor, Thomas; Ohorodnik, Susan; Reed, David; Wietgrefe, Holly D

    2010-12-01

    Nonclinical dose formulation analysis methods are used to confirm test article concentration and homogeneity in formulations and determine formulation stability in support of regulated nonclinical studies. There is currently no regulatory guidance for nonclinical dose formulation analysis method validation or sample analysis. Regulatory guidance for the validation of analytical procedures has been developed for drug product/formulation testing; however, verification of the formulation concentrations falls under the framework of GLP regulations (not GMP). The only current related regulatory guidance is the bioanalytical guidance for method validation. The fundamental parameters for bioanalysis and formulation analysis validations that overlap include: recovery, accuracy, precision, specificity, selectivity, carryover, sensitivity, and stability. Divergence in bioanalytical and drug product validations typically center around the acceptance criteria used. As the dose formulation samples are not true "unknowns", the concept of quality control samples that cover the entire range of the standard curve serving as the indication for the confidence in the data generated from the "unknown" study samples may not always be necessary. Also, the standard bioanalytical acceptance criteria may not be directly applicable, especially when the determined concentration does not match the target concentration. This paper attempts to reconcile the different practices being performed in the community and to provide recommendations of best practices and proposed acceptance criteria for nonclinical dose formulation method validation and sample analysis.

  15. Sample preparation for radiocarbon ( 14C) measurements of carbonyl compounds in the atmosphere . quantifying the biogenic contribution

    NASA Astrophysics Data System (ADS)

    Larsen, B. R.; Brussol, C.; Kotzias, D.; Veltkamp, T.; Zwaagstra, O.; Slanina, J.

    A method has been developed for the preparation of samples for radiocarbon ( 14C) measurements of carbonyl compounds in the atmosphere. Sampling on 25 ml 2,4-dinitrophenylhydrazine (DNPH)- coated silica gel cartridges can be carried out with up to 10.000 ℓ of ambient air with no adverse effects on sample integrity. Methods for the selective clean-up of the extracts have been investigated. This is a necessary step in preparing ambient carbonyl samples for a measurement of the radiocarbon ( 14C) content. The method which gave the best results include extraction of the DNPH cartridge with CH 3CN and purification of the carbonyl hydrazones over activated silica gel to remove excess DNPH and non target compounds. This method has been validated with laboratory samples and has been proved to give reliable results The radiocarbon data from the first field experiment showed that ambient air over a semi-rural test site in Ispra, Italy on a late summer day contained mainly five carbonyls (formaldehyde>acetaldehyde>acetone>propanal>butanal) of a mixed biogenic (41-57%) and anthropogenic (43-59%) origin. The method will be used in future monitoring of radiocarbon ( 14C) on a number of test sites in Europe.

  16. Detection of Salmonella spp. in veterinary samples by combining selective enrichment and real-time PCR.

    PubMed

    Goodman, Laura B; McDonough, Patrick L; Anderson, Renee R; Franklin-Guild, Rebecca J; Ryan, James R; Perkins, Gillian A; Thachil, Anil J; Glaser, Amy L; Thompson, Belinda S

    2017-11-01

    Rapid screening for enteric bacterial pathogens in clinical environments is essential for biosecurity. Salmonella found in veterinary hospitals, particularly Salmonella enterica serovar Dublin, can pose unique challenges for culture and testing because of its poor growth. Multiple Salmonella serovars including Dublin are emerging threats to public health given increasing prevalence and antimicrobial resistance. We adapted an automated food testing method to veterinary samples and evaluated the performance of the method in a variety of matrices including environmental samples ( n = 81), tissues ( n = 52), feces ( n = 148), and feed ( n = 29). A commercial kit was chosen as the basis for this approach in view of extensive performance characterizations published by multiple independent organizations. A workflow was established for efficiently and accurately testing veterinary matrices and environmental samples by use of real-time PCR after selective enrichment in Rappaport-Vassiliadis soya (RVS) medium. Using this method, the detection limit for S. Dublin improved by 100-fold over subculture on selective agars (eosin-methylene blue, brilliant green, and xylose-lysine-deoxycholate). Overall, the procedure was effective in detecting Salmonella spp. and provided next-day results.

  17. Photometric and Colorimetric Assessment of LED Chip Scale Packages by Using a Step-Stress Accelerated Degradation Test (SSADT) Method.

    PubMed

    Qian, Cheng; Fan, Jiajie; Fang, Jiayi; Yu, Chaohua; Ren, Yi; Fan, Xuejun; Zhang, Guoqi

    2017-10-16

    By solving the problem of very long test time on reliability qualification for Light-emitting Diode (LED) products, the accelerated degradation test with a thermal overstress at a proper range is regarded as a promising and effective approach. For a comprehensive survey of the application of step-stress accelerated degradation test (SSADT) in LEDs, the thermal, photometric, and colorimetric properties of two types of LED chip scale packages (CSPs), i.e., 4000 °K and 5000 °K samples each of which was driven by two different levels of currents (i.e., 120 mA and 350 mA, respectively), were investigated under an increasing temperature from 55 °C to 150 °C and a systemic study of driving current effect on the SSADT results were also reported in this paper. During SSADT, junction temperatures of the test samples have a positive relationship with their driving currents. However, the temperature-voltage curve, which represents the thermal resistance property of the test samples, does not show significant variance as long as the driving current is no more than the sample's rated current. But when the test sample is tested under an overdrive current, its temperature-voltage curve is observed as obviously shifted to the left when compared to that before SSADT. Similar overdrive current affected the degradation scenario is also found in the attenuation of Spectral Power Distributions (SPDs) of the test samples. As used in the reliability qualification, SSADT provides explicit scenes on color shift and correlated color temperature (CCT) depreciation of the test samples, but not on lumen maintenance depreciation. It is also proved that the varying rates of the color shift and CCT depreciation failures can be effectively accelerated with an increase of the driving current, for instance, from 120 mA to 350 mA. For these reasons, SSADT is considered as a suitable accelerated test method for qualifying these two failure modes of LED CSPs.

  18. Multi-Reader ROC studies with Split-Plot Designs: A Comparison of Statistical Methods

    PubMed Central

    Obuchowski, Nancy A.; Gallas, Brandon D.; Hillis, Stephen L.

    2012-01-01

    Rationale and Objectives Multi-reader imaging trials often use a factorial design, where study patients undergo testing with all imaging modalities and readers interpret the results of all tests for all patients. A drawback of the design is the large number of interpretations required of each reader. Split-plot designs have been proposed as an alternative, in which one or a subset of readers interprets all images of a sample of patients, while other readers interpret the images of other samples of patients. In this paper we compare three methods of analysis for the split-plot design. Materials and Methods Three statistical methods are presented: Obuchowski-Rockette method modified for the split-plot design, a newly proposed marginal-mean ANOVA approach, and an extension of the three-sample U-statistic method. A simulation study using the Roe-Metz model was performed to compare the type I error rate, power and confidence interval coverage of the three test statistics. Results The type I error rates for all three methods are close to the nominal level but tend to be slightly conservative. The statistical power is nearly identical for the three methods. The coverage of 95% CIs fall close to the nominal coverage for small and large sample sizes. Conclusions The split-plot MRMC study design can be statistically efficient compared with the factorial design, reducing the number of interpretations required per reader. Three methods of analysis, shown to have nominal type I error rate, similar power, and nominal CI coverage, are available for this study design. PMID:23122570

  19. COMPARISON OF IMMUNOASSAY AND GAS CHROMATOGRAPHY/MASS SPECTROMETRY METHODS FOR MEASURING 3,5,6-TRICHLORO-2PYRIDINOL IN MULTIPLE SAMPLE MEDIA

    EPA Science Inventory

    Two enzyme-linked immunosorbent assay (ELISA) methods were evaluated for the determination of 3,5,6-trichloro-2-pyridinol (3,5,6-TCP) in multiple sample media (dust, soil, food, and urine). The dust and soil samples were analyzed by a commercial RaPID immunoassay testing kit. ...

  20. Confirmatory and quantitative analysis of beta-lactam antibiotics in bovine kidney tissue by dispersive solid-phase extraction and liquid chromatography-tandem mass spectrometry.

    PubMed

    Fagerquist, Clifton K; Lightfield, Alan R; Lehotay, Steven J

    2005-03-01

    A simple, rapid, rugged, sensitive, and specific method for the confirmation and quantitation of 10 beta-lactam antibiotics in fortified and incurred bovine kidney tissue has been developed. The method uses a simple solvent extraction, dispersive solid-phase extraction (dispersive-SPE) cleanup, and liquid chromatography-tandem mass spectrometry (LC/MS/MS) for confirmation and quantitation. Dispersive-SPE greatly simplifies and accelerates sample cleanup and improves overall recoveries compared with conventional SPE cleanup. The beta-lactam antibiotics tested were as follows: deacetylcephapirin (an antimicrobial metabolite of cephapirin), amoxicillin, desfuroylceftiofur cysteine disulfide (DCCD, an antimicrobial metabolite of ceftiofur), ampicillin, cefazolin, penicillin G, oxacillin, cloxacillin, naficillin, and dicloxacillin. Average recoveries of fortified samples were 70% or better for all beta-lactams except DCCD, which had an average recovery of 58%. The LC/MS/MS method was able to demonstrate quantitative recoveries at established tolerance levels and provide confirmatory data for unambiguous analyte identification. The method was also tested on 30 incurred bovine kidney samples obtained from the USDA Food Safety and Inspection Service, which had previously tested the samples using the approved semiquantitative microbial assay. The results from the quantitative LC/MS/MS analysis were in general agreement with the microbial assay for 23 samples although the LC/MS/MS method was superior in that it could specifically identify which beta-lactam was present and quantitate its concentration, whereas the microbial assay could only identify the type of beta-lactam present and report a concentration with respect to the microbial inhibition of a penicillin G standard. In addition, for 6 of the 23 samples, LC/MS/MS analysis detected a penicillin and a cephalosporin beta-lactam, whereas the microbial assay detected only a penicillin beta-lactam. For samples that do not fall into the "general agreement" category, the most serious discrepancy involves two samples where the LC/MS/MS method detected a violative level of a cephalosporin beta-lactam (deacetylcephapirin) in the first sample and a possibly violative level of desfuroylceftiofur in the second, whereas the microbial assay identified the two samples as having only violative levels of a penicillin beta-lactam.

Top