Sample records for test plan template

  1. SU-F-BRD-10: Lung IMRT Planning Using Standardized Beam Bouquet Templates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yuan, L; Wu, Q J.; Yin, F

    2014-06-15

    Purpose: We investigate the feasibility of choosing from a small set of standardized templates of beam bouquets (i.e., entire beam configuration settings) for lung IMRT planning to improve planning efficiency and quality consistency, and also to facilitate automated planning. Methods: A set of beam bouquet templates is determined by learning from the beam angle settings in 60 clinical lung IMRT plans. A k-medoids cluster analysis method is used to classify the beam angle configuration into clusters. The value of the average silhouette width is used to determine the ideal number of clusters. The beam arrangements in each medoid of themore » resulting clusters are taken as the standardized beam bouquet for the cluster, with the corresponding case taken as the reference case. The resulting set of beam bouquet templates was used to re-plan 20 cases randomly selected from the database and the dosimetric quality of the plans was evaluated against the corresponding clinical plans by a paired t-test. The template for each test case was manually selected by a planner based on the match between the test and reference cases. Results: The dosimetric parameters (mean±S.D. in percentage of prescription dose) of the plans using 6 beam bouquet templates and those of the clinical plans, respectively, and the p-values (in parenthesis) are: lung Dmean: 18.8±7.0, 19.2±7.0 (0.28), esophagus Dmean: 32.0±16.3, 34.4±17.9 (0.01), heart Dmean: 19.2±16.5, 19.4±16.6 (0.74), spinal cord D2%: 47.7±18.8, 52.0±20.3 (0.01), PTV dose homogeneity (D2%-D99%): 17.1±15.4, 20.7±12.2 (0.03).The esophagus Dmean, cord D02 and PTV dose homogeneity are statistically better in the plans using the standardized templates, but the improvements (<5%) may not be clinically significant. The other dosimetric parameters are not statistically different. Conclusion: It's feasible to use a small number of standardized beam bouquet templates (e.g. 6) to generate plans with quality comparable to that of clinical plans. Partially supported by NIH/NCI under grant #R21CA161389 and a master research grant by Varian Medical System.« less

  2. [CT guidance 125I seed implantation for pelvic recurrent rectal cancer assisted by 3D printing individual non-coplanar template].

    PubMed

    Wang, H; Wang, J J; Jiang, Y L; Tian, S Q; Ji, Z; Guo, F X; Sun, H T; Fan, J H; Xu, Y P

    2016-12-20

    Objective: To analyze the difference of dosimetric parameters between pre-plan and post-plan of 125 I radioactive seed implantation assisted by 3D printing individual non-coplanar template (3D printing template) for locally recurrent rectal cancer (LRRC). Methods: From February 2016 to April 2016, a total of 10 patients with locally recurrent rectal cancer received 125 I seeds implantation under CT guidance assisted by 3D printing template in Department of Radiation Oncology, Peking University Third Hospital.Each patient underwent CT simulation, three-dimentional treatment planning pre-implantation, 3D printing template design, radioactive seed implantation assisted by 3D printing template and dosimetric verification post implantation. The median activity of seed was 0.63 mCi (0.58 to 0.7 mCi) (2.15- 2.59×10 7 Bq), and the median number of seeds was 80 (19 to 192). D 90 , D 100 , V 100 , V 150 , CI, EI, HI, D 5cc , D 2cc of bladder and bowel of pre-plan and post-plan were calculated, respectively.Paired t test was used to evaluate the difference of dosimetric parameters between pre-plan and post-plan. Results: The median D 90 of pre-plan and post-plan were 13 761.0 and 12 798.8 cGy, respectively.The median D 100 of pre-plan and post-plan were 5 293.6 and 5 397.9 cGy, respectively.The median V 100 of pre-plan and post-plan were 90.0% and 90.0%, respectively.The median V 150 of pre-plan and post-plan were 63.8% and 62.4%, respectively.The median CI of pre-plan and post-plan were 0.73 and 0.67.The median EI of pre-plan and post-plan were 0.22 and 0.30, respectively. The median HI of pre-plan and post-plan were 0.29 and 0.31.The median bladder D 2cc of pre-plan and post-plan were 3 088.8 and 4 240.4 cGy, respectively.The median bowel D 2cc of pre-plan and post-plan were 7 051.6 and 7 903.9 cGy, respectively. Conclusions: 3D printing template might be helpful for locally recurrent rectal cancer patients who received 125 I radioactive seed implantation assisted by 3D printing individual template.Seed implantation might have more chances to achieve prescription dose and dose limitation of organs at risk of pre-plan, which is important for precise implantation and quality control.

  3. China SLAT Plan Template

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dietrich, Richard E.

    2016-07-01

    This document serves as the System-Level Acceptance Test (SLAT) Plan for Site Name, City, Country. This test plan is to provide independent testing of the Radiation Detection System (RDS) installed at Site Name to verify that Customs has been delivered a fully-functioning system as required by all contractual commitments. The system includes all installed hardware and software components. The SLAT plan will verify that separate components are working individually and collectively from a system perspective.

  4. Variance in predicted cup size by 2-dimensional vs 3-dimensional computerized tomography-based templating in primary total hip arthroplasty.

    PubMed

    Osmani, Feroz A; Thakkar, Savyasachi; Ramme, Austin; Elbuluk, Ameer; Wojack, Paul; Vigdorchik, Jonathan M

    2017-12-01

    Preoperative total hip arthroplasty templating can be performed with radiographs using acetate prints, digital viewing software, or with computed tomography (CT) images. Our hypothesis is that 3D templating is more precise and accurate with cup size prediction as compared to 2D templating with acetate prints and digital templating software. Data collected from 45 patients undergoing robotic-assisted total hip arthroplasty compared cup sizes templated on acetate prints and OrthoView software to MAKOplasty software that uses CT scan. Kappa analysis determined strength of agreement between each templating modality and the final size used. t tests compared mean cup-size variance from the final size for each templating technique. Interclass correlation coefficient (ICC) determined reliability of digital and acetate planning by comparing predictions of the operating surgeon and a blinded adult reconstructive fellow. The Kappa values for CT-guided, digital, and acetate templating with the final size was 0.974, 0.233, and 0.262, respectively. Both digital and acetate templating significantly overpredicted cup size, compared to CT-guided methods ( P < .001). There was no significant difference between digital and acetate templating ( P  = .117). Interclass correlation coefficient value for digital and acetate templating was 0.928 and 0.931, respectively. CT-guided planning more accurately predicts hip implant cup size when compared to the significant overpredictions of digital and acetate templating. CT-guided templating may also lead to better outcomes due to bone stock preservation from a smaller and more accurate cup size predicted than that of digital and acetate predictions.

  5. Effect of length and location of edentulous area on the accuracy of prosthetic treatment plan incorporation into cone-beam computed tomography scans.

    PubMed

    Jamjoom, Faris Z; Kim, Do-Gyoon; Lee, Damian J; McGlumphy, Edwin A; Yilmaz, Burak

    2018-02-05

    Effects of length and location of the edentulous area on the accuracy of prosthetic treatment plan incorporation into cone-beam computed tomography (CBCT) scans has not been investigated. To evaluate the effect of length and location of the edentulous area on the accuracy of prosthetic treatment plan incorporation into CBCT scans using different methods. Direct digital scans of a completely dentate master model with removable radiopaque teeth were made using an intraoral scanner, and digital scans of stone duplicates of the master model were made using a laboratory scanner. Specific teeth were removed to simulate different clinical situations and their CBCT scans were made. Surface scans were registered onto the CBCT scans. Radiographic templates for each clinical situation were also fabricated and used during CBCT scans of the master models. Using metrology software, three-dimensional (3D) deviation was measured on standard tesselation language (STL) files created from the CBCT scans against an STL file of the master model created from a CBCT scan. Statistical analysis was done using the MIXED procedure in a statistical software and Tukey HSD test (α =.05). The interaction between location and method was significant (P = .009). Location had no significant effect on registration methods (P > .05), but on the radiographic templates (P = .011). Length of the edentulous area did not have any significant effect (P > .05). Accuracy of digital image registration methods was similar and higher than that of radiographic templates in all clinical situations. Tooth-bound radiographic templates were significantly more accurate than the free-end templates. The results of this study suggest using image registration instead of radiographic templates when planning dental implants, particularly in free-end situations. © 2018 Wiley Periodicals, Inc.

  6. Are care plans suitable for the management of multiple conditions?

    PubMed Central

    Young, Charlotte E.; Boyle, Frances M.; Mutch, Allyson J.

    2016-01-01

    Background Care plans have been part of the primary care landscape in Australia for almost two decades. With an increasing number of patients presenting with multiple chronic conditions, it is timely to consider whether care plans meet the needs of patients and clinicians. Objectives To review and benchmark existing care plan templates that include recommendations for comorbid conditions, against four key criteria: (i) patient preferences, (ii) setting priorities, (iii) identifying conflicts and synergies between conditions, and (iv) setting dates for reviewing the care plan. Design Document analysis of Australian care plan templates published from 2006 to 2014 that incorporated recommendations for managing comorbid conditions in primary care. Results Sixteen templates were reviewed. All of the care plan templates addressed patient preference, but this was not done comprehensively. Only three templates included setting priorities. None assisted in identifying conflicts and synergies between conditions. Fifteen templates included setting a date for reviewing the care plan. Conclusions Care plans are a well-used tool in primary care practice, but their current format perpetuates a single-disease approach to care, which works contrary to their intended purpose. Restructuring care plans to incorporate shared decision-making and attention to patient preferences may assist in shifting the focus back to the patient and their care needs. PMID:29090181

  7. Prostate Brachytherapy With Oblique Needles to Treat Large Glands and Overcome Pubic Arch Interference

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ryu, Bon; Imaging Research Laboratories, Robarts Research Institute, University of Western Ontario, London, Ontario; Bax, Jeff

    2012-08-01

    Purpose: First, to show that low-dose-rate prostate brachytherapy plans using oblique needle trajectories are more successful than parallel trajectories for large prostates with pubic arch interference (PAI); second, to test the accuracy of delivering an oblique plan by using a three-dimensional (3D) transrectal ultrasonography (TRUS)-guided mechatronic system. Methods and Materials: Prostates were contoured for 5 subjects' 3D TRUS images showing a maximum PAI of {<=}1 cm and a prostate volume of <50 cc. Two planning studies were done. First, prostate contours were artificially enlarged to 45 to 80 cc in 5- to 10-cc increments for a single subject. Second, allmore » subject prostate contours were enlarged to 60 cc. For each study, three types of plans were manually created for comparison: a parallel needle template (PT) plan, a parallel needle no-template (PNT) plan, and an oblique needle no-template (OBL) plan. Needle positions and angles were not discretized for nontemplate plans. European Society for Therapeutic Radiology and Oncology dose-volume histogram guidelines, iodine-125 (145-Gy prescription, 0.43 U), and needle angles of <15 Degree-Sign were used. An OBL plan was delivered to a pubic arch containing a 60-cc prostate phantom that mimicked the anatomy of the subject with the greatest PAI (23% by volume). Results: In the increasing-prostate volume study, OBL plans were successful for prostates of {<=}80 cc, and PT plans were successful for prostates of <65 cc. In paired, one-sided t tests for the 60-cc volume study, OBL plans showed dosimetric improvements for all organs compared to both of the parallel type plans (p < 0.05); PNT plans showed a benefit only in planning target volumes receiving more than 100 Gy compared to PT plans. A computed tomography scan of the phantom showed submillimeter seed placement accuracy in all directions. Conclusion: OBL plans were significantly better than parallel plans, and an OBL plan was accurately delivered to a 60-cc prostate phantom with 23% PAI by volume.« less

  8. Dimethyl Disulfide (DMDS) Fumigant Management Plan Template Phase 2

    EPA Pesticide Factsheets

    These templates provide a framework for developing your FMP, including sections on your supervising pesticide applicator, buffer zones, emergency response plan, handler information, tarp plan, soil conditions, signage, and air monitoring plan.

  9. Operating and Maintaining Energy Smart Schools Action Plan Template - All Action Plans

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    2009-07-01

    EnergySmart Schools action plan templates for benchmarking, lighting, HVAC, water heating, building envelope, transformer, plug loads, kitchen equipment, swimming pool, building automation system, other.

  10. Comparing a volume based template approach and ultrasound guided freehand approach in multicatheter interstitial accelerated partial breast irradiation.

    PubMed

    Koh, Vicky Y; Buhari, Shaik A; Tan, Poh Wee; Tan, Yun Inn; Leong, Yuh Fun; Earnest, Arul; Tang, Johann I

    2014-06-01

    Currently, there are two described methods of catheter insertion for women undergoing multicatheter interstitial accelerated partial breast irradiation (APBI). These are a volume based template approach (template) and a non-template ultrasound guidance freehand approach (non-template). We aim to compare dosimetric endpoints between the template and non-template approach. Twenty patients, who received adjuvant multicatheter interstitial APBI between August 2008 to March 2010 formed the study cohort. Dosimetric planning was based on the RTOG 04-13 protocol. For standardization, the planning target volume evaluation (PTV-Eval) and organs at risk were contoured with the assistance of the attending surgeon. Dosimetric endpoints include D90 of the PTV-Eval, Dose Homogeneity Index (DHI), V200, maximum skin dose (MSD), and maximum chest wall dose (MCD). A median of 18 catheters was used per patient. The dose prescribed was 34 Gy in 10 fractions BID over 5 days. The average breast volume was 846 cm(3) (526-1384) for the entire cohort and there was no difference between the two groups (p = 0.6). Insertion time was significantly longer for the non-template approach (mean 150 minutes) compared to the template approach (mean: 90 minutes) (p = 0.02). The planning time was also significantly longer for the non-template approach (mean: 240 minutes) compared to the template approach (mean: 150 minutes) (p < 0.01). The template approach yielded a higher D90 (mean: 95%) compared to the non-template approach (mean: 92%) (p < 0.01). There were no differences in DHI (p = 0.14), V200 (p = 0.21), MSD (p = 0.7), and MCD (p = 0.8). Compared to the non-template approach, the template approach offered significant shorter insertion and planning times with significantly improved dosimetric PTV-Eval coverage without significantly compromising organs at risk dosimetrically.

  11. Metam Sodium and Metam Potassium Fumigant Management Plan Phase 2 Templates

    EPA Pesticide Factsheets

    These templates provide a framework for structuring and reporting a plan for this type of pesticide product. Required data fields include application block size, buffer zone signage, soil conditions, and tarp plans.

  12. Dazomet Fumigant Management Plan Phase 2 Templates

    EPA Pesticide Factsheets

    These templates provide a framework for reporting application block information, buffer zones, emergency response plan, tarp plan, soil conditions, air monitoring, and more for pesticide products containing the active ingredient dazomet, such as Basamid G.

  13. Prostate intensity-modulated radiotherapy planning in seven mouse clicks: Development of a class solution for cancer.

    PubMed

    Wood, Maree; Fonseca, Amara; Sampson, David; Kovendy, Andrew; Westhuyzen, Justin; Shakespeare, Thomas; Turnbull, Kirsty

    2016-01-01

    The aim of the retrospective study was to develop a planning class solution for prostate intensity-modulated radiotherapy (IMRT) that achieved target and organs-at-risk (OAR) doses within acceptable departmental protocol criteria using the Monaco treatment planning system (Elekta-CMS Software, MO, USA). Advances in radiation therapy technology have led to a re-evaluation of work practices. Class solutions have the potential to produce highly conformal plans in a time-efficient manner. Using data from intermediate and high risk prostate cancer patients, a stepwise quality improvement model was employed. Stage 1 involved the development of a broadly based treatment template developed across 10 patients. Stage 2 involved template refinement and clinical audit ( n  = 20); Stage 3, template review ( n  = 50) and Stage 4 an assessment of a revised template against the actual treatment plan involving 72 patients. The computer algorithm that comprised the Stage 4 template met clinical treatment criteria for 82% of patients. Minor template changes were required for a further 13% of patients. Major changes were required in 4%; one patient could not be assessed. The average calculation time was 13 min and involved seven mouse clicks by the planner. Thus, the new template met treatment criteria or required only minor changes in 95% of prostate patients; this is an encouraging result suggesting improvements in planning efficiency and consistency. It is feasible to develop a class solution for prostate IMRT using a stepwise quality improvement model which delivers clinically acceptable plans in the great majority of prostate cases.

  14. Wave Energy Prize - General Information

    DOE Data Explorer

    Scharmen, Wesley

    2016-12-01

    All the informational files, templates, rules and guidelines for Wave Energy Prize (WEP), including the Wave Energy Prize Rules, Participant Terms and Conditions Template, WEC Prize Name, Logo, Branding, WEC Publicity, Technical Submission Template , Numerical Modeling Template, SSTF Submission Template, 1/20th Scale Model Design and Construction Plan Template, Final Report template, and Webinars.

  15. Digital templating for THA: a simple computer-assisted application for complex hip arthritis cases.

    PubMed

    Hafez, Mahmoud A; Ragheb, Gad; Hamed, Adel; Ali, Amr; Karim, Said

    2016-10-01

    Total hip arthroplasty (THA) is the standard procedure for end-stage arthritis of the hip. Its technical success relies on preoperative planning of the surgical procedure and virtual setup of the operative performance. Digital hip templating is one methodology of preoperative planning for THA which requires a digital preoperative radiograph and a computer with special software. This is a prospective study involving 23 patients (25 hips) who were candidates for complex THA surgery (unilateral or bilateral). Digital templating is done by radiographic assessment using radiographic magnification correction, leg length discrepancy and correction measurements, acetabular component and femoral component templating as well as neck resection measurement. The overall accuracy for templating the stem implant's exact size is 81%. This percentage increased to 94% when considering sizing within 1 size. Digital templating has proven effective, reliable and essential technique for preoperative planning and accurate prediction of THA sizing and alignment.

  16. Berkeley Lab - Materials Sciences Division

    Science.gov Websites

    ; Finance Templates Travel One-Stop Acknowledging MSD Support Human Resources Facilities & Space Planning Procurement and Property Proposals & Finance Templates Travel Facilities & Space Planning

  17. Methyl Bromide Fumigant Management Plan Phase 2 Templates

    EPA Pesticide Factsheets

    Templates provide a checklist and framework for elements including certified pesticide applicator details, application block, buffer zones, sign posting, tarp plan, soil conditions, air monitoring, and good agricultural practices (GAPs).

  18. Developing Customized Dental Miniscrew Surgical Template from Thermoplastic Polymer Material Using Image Superimposition, CAD System, and 3D Printing

    PubMed Central

    Yu, Jian-Hong; Lo, Lun-Jou; Hsu, Pin-Hsin

    2017-01-01

    This study integrates cone-beam computed tomography (CBCT)/laser scan image superposition, computer-aided design (CAD), and 3D printing (3DP) to develop a technology for producing customized dental (orthodontic) miniscrew surgical templates using polymer material. Maxillary bone solid models with the bone and teeth reconstructed using CBCT images and teeth and mucosa outer profile acquired using laser scanning were superimposed to allow miniscrew visual insertion planning and permit surgical template fabrication. The customized surgical template CAD model was fabricated offset based on the teeth/mucosa/bracket contour profiles in the superimposition model and exported to duplicate the plastic template using the 3DP technique and polymer material. An anterior retraction and intrusion clinical test for the maxillary canines/incisors showed that two miniscrews were placed safely and did not produce inflammation or other discomfort symptoms one week after surgery. The fitness between the mucosa and template indicated that the average gap sizes were found smaller than 0.5 mm and confirmed that the surgical template presented good holding power and well-fitting adaption. This study addressed integrating CBCT and laser scan image superposition; CAD and 3DP techniques can be applied to fabricate an accurate customized surgical template for dental orthodontic miniscrews. PMID:28280726

  19. Sample transportation management plans and templates.

    DOT National Transportation Integrated Search

    2010-08-01

    This Guide consisting of samples, templates, and tips is designed to help transportation agencies with the : development and implementation of their own Transportation Management Plans (TMPs). Understanding : the work zone impacts is critical to deve...

  20. 78 FR 47329 - Agency Information Collection Activities: Proposed Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-05

    ... planning communities, plans, protocols, and procedures to manage a catastrophic event. The RCPGP is... collection. FEMA Forms: FEMA Form 089-19, RCPGP Investment Justification Template; FEMA Form 089-26, RCGCP (Sample) Detailed Project Plan Template; FEMA Form 089-17, RCPT Membership List. Abstract: The RCPGP is an...

  1. Environmental Learning Centers: A Template.

    ERIC Educational Resources Information Center

    Vozick, Eric

    1999-01-01

    Provides a working model, or template, for community-based environmental learning centers (ELCs). The template presents a philosophy as well as a plan for staff and administration operations, educational programming, and financial support. The template also addresses "green" construction and maintenance of buildings and grounds and…

  2. A single appointment protocol to create a partially edentulous CAD/CAM guided surgical template: a clinical report.

    PubMed

    Marchack, Christopher B; Charles, Allan; Pettersson, Andreas

    2011-12-01

    The traditional technique for creating a CAD/CAM surgical template with a NobelGuide protocol is to fabricate a radiographic template that depicts the planned tooth position first. Multiple appointments are needed for the fabrication of the radiographic template with Cone Beam Computed Tomography (CBCT) before the surgical procedure can start. An alternative technique is described for fabricating a radiographic template at the initial examination appointment and capturing the necessary DICOM data to plan and fabricate a CAD/CAM surgical template in a 1-appointment protocol, thereby saving the patient and clinician time and reducing the need for multiple appointments. Copyright © 2011 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  3. A New Planning Template for Transit-Oriented Development

    DOT National Transportation Integrated Search

    2001-09-01

    The Mineta Transportation Institute (MTI) at San Josi State University assigned a project team to design a planning template for transit-oriented development (TOD) that incorporates an understanding of nonwork travel, that is, trips for shopping, eat...

  4. Small city synthesis of transportation planning and economic development : user's guide

    DOT National Transportation Integrated Search

    1999-10-01

    Using Alice, Texas, as a model, a template has been developed to increase the cooperation and communication between transportation planning and economic development groups. The template establishes a foundation for coordinating traffic forecasts with...

  5. Fumigant Management Plan Templates - Phase 2 Files Listed by Chemical

    EPA Pesticide Factsheets

    FMP templates are in PDF and Word formats for each type of soil fumigant pesticide, with samples of filled out plans. Types are by active ingredient chemical: Chloropicrin, dazomet, dimethyl disulfide, metam sodium/potassium, and methyl bromide.

  6. Berkeley Lab - Materials Sciences Division

    Science.gov Websites

    MSD Support Human Resources Facilities & Space Planning Procurement and Property Proposals & ; Finance Templates Travel One-Stop Acknowledging MSD Support Human Resources Facilities & Space Planning Procurement and Property Proposals & Finance Templates Travel Human Resources General

  7. Cloud-based preoperative planning for total hip arthroplasty: a study of accuracy, efficiency, and compliance.

    PubMed

    Maratt, Joseph D; Srinivasan, Ramesh C; Dahl, William J; Schilling, Peter L; Urquhart, Andrew G

    2012-08-01

    As digital radiography becomes more prevalent, several systems for digital preoperative planning have become available. The purpose of this study was to evaluate the accuracy and efficiency of an inexpensive, cloud-based digital templating system, which is comparable with acetate templating. However, cloud-based templating is substantially faster and more convenient than acetate templating or locally installed software. Although this is a practical solution for this particular medical application, regulatory changes are necessary before the tremendous advantages of cloud-based storage and computing can be realized in medical research and clinical practice. Copyright 2012, SLACK Incorporated.

  8. [Dosimetry verification of radioactive seed implantation with 3D printing template and CT guidance for paravertebral/retroperitoneal malignant tumor].

    PubMed

    Ji, Z; Jiang, Y L; Guo, F X; Peng, R; Sun, H T; Fan, J H; Wang, J J

    2017-04-04

    Objective: To compare the dose distributions of postoperative plans with preoperative plans for seeds implantations of paravertebral/retroperitoneal tumors assisted by 3D printing guide template and CT guidance, explore the effects of the technology for seeds implantations in dosimetry level and provide data support for the optimization and standardization in seeds implantation. Methods: Between December 2015 and July 2016, a total of 10 patients with paravertebral/retroperitoneal tumors (12 lesions) received 3D printing template assist radioactive seeds implantations in department of radiation oncology of Peking University Third Hospital, and included in the study. The diseases included cervical cancer, kidney cancer, abdominal stromal tumor, leiomyosarcoma of kidney, esophageal cancer and carcinoma of ureter. The prescribed doses was 110-150 Gy. All patients received preoperative planning design, individual template design and production, and the dose distribution of postoperative plan was compared with preoperative plan. Dose parameters including D(90), MPD, V(100), V(150,)conformal index(CI), EI of target volume and D(2cc) of organs at risk (spinal cord, aorta, kidney). Statistical software was SPSS 19.0 and statistical method was non-parameters Wilcoxon symbols test. Results: A total of 10 3D printing templates were designed and produced which were including 12 treatment areas.The mean D(90) of postoperative target area (GTV) was 131.1 (97.8-167.4 Gy) Gy. The actual seeds number of post operation increased by 3 to 12 in 5 cases (42.0%). The needle was well distributed. For postoperative plans, the mean D(90,)MPD, V(100,)V(150) was 131.1 Gy, 69.3 Gy, 90.2% and 65.2%, respectively, and which was 140.2 Gy, 65.6 Gy, 91.7% and 26.8%, respectively, in preoperative plans. This meant that the actual dose of target volume was slightly lower than preplanned dose, and the high dose area of target volume was larger than preplanned range, but there was no statistical difference in P value between the two groups except V(150)( P =0.004). The actual dose conformity of target volume was worse than preplanned (CI was 0.58 and 0.62, respectively) and the difference was statistically significant( P =0.019). The actual dose of external target volume was higher than preplanned (EI was 55% and 45.9%, respectively) and the difference had no significance. For organs at risk, the actual mean D(2cc) of spinal cord, aorta and kidney was 24.7, 54.4 and 29.7 Gy, respectively, which was higher than preplanned(20.6, 51.6 and 28.6 Gy, respectively), and there was no significant difference in two groups. Conclusions: Most parameters of postoperative validations for 3D printing template assisted seeds implantation in paravertebral/retroperitoneal are closed to the expectations of preoperative plans which means the improvement of accuracy in treatment.

  9. Development and evaluation of an aged care specific Advance Care Plan.

    PubMed

    Silvester, William; Parslow, Ruth A; Lewis, Virginia J; Fullam, Rachael S; Sjanta, Rebekah; Jackson, Lynne; White, Vanessa; Hudson, Rosalie

    2013-06-01

    To report on the quality of advance care planning (ACP) documents in use in residential aged care facilities (RACF) in areas of Victoria Australia prior to a systematic intervention; to report on the development and performance of an aged care specific Advance Care Plan template used during the intervention. An audit of the quality of pre-existing documentation used to record resident treatment preferences and end-of-life wishes at participating RACFs; development and pilot of an aged care specific Advance Care Plan template; an audit of the completeness and quality of Advance Care Plans completed on the new template during a systematic ACP intervention. 19 selected RACFs (managed by 12 aged care organisations) in metropolitan and regional areas of Victoria. Documentation in use at facilities prior to the ACP intervention most commonly recorded preferences regarding hospital transfer, life prolonging treatment and personal/cultural/religious wishes. However, 7 of 12 document sets failed to adequately and clearly specify the resident's preferences as regards life prolonging medical treatment. The newly developed aged care specific Advance Care Plan template was met with approval by participating RACFs. Of 203 Advance Care Plans completed on the template throughout the project period, 49% included the appointment of a Medical Enduring Power of Attorney. Requests concerning medical treatment were specified in almost all completed documents (97%), with 73% nominating the option of refusal of life-prolonging treatment. Over 90% of plans included information concerning residents' values and beliefs, and future health situations that the resident would find to be unacceptable were specified in 78% of completed plans. Standardised procedures and documentation are needed to improve the quality of processes, documents and outcomes of ACP in the residential aged care sector.

  10. Fumigant Management Plan - Phase 1 Templates

    EPA Pesticide Factsheets

    FMPs are required by pesticide labels, so EPA provides chemical-specific soil fumigant templates and samples in PDF and Word formats. Choose the appropriate template for products containing chloropicrin, dazomet, metam sodium/potassium, or methyl bromide.

  11. Sampling and Analysis Plan - Guidance and Template v.4 - General Projects - 04/2014

    EPA Pesticide Factsheets

    This Sampling and Analysis Plan (SAP) guidance and template is intended to assist organizations in documenting the procedural and analytical requirements for one-time, or time-limited, projects involving the collection of water, soil, sediment, or other

  12. Computer-aided design and manufacturing of surgical templates and their clinical applications: a review.

    PubMed

    Chen, Xiaojun; Xu, Lu; Wang, Wei; Li, Xing; Sun, Yi; Politis, Constantinus

    2016-09-01

    The surgical template is a guide aimed at directing the implant placement, tumor resection, osteotomy and bone repositioning. Using it, preoperative planning can be transferred to the actual surgical site, and the precision, safety and reliability of the surgery can be improved. However, the actual workflow of the surgical template design and manufacturing is quite complicated before the final clinical application. The major goal of the paper is to provide a comprehensive reference source of the current and future development of the template design and manufacturing for relevant researchers. Expert commentary: This paper aims to present a review of the necessary procedures in the template-guided surgery including the image processing, 3D visualization, preoperative planning, surgical guide design and manufacturing. In addition, the template-guided clinical applications for various kinds of surgeries are reviewed, and it demonstrated that the precision of the surgery has been improved compared with the non-guided operations.

  13. A template for integrated community sustainability planning.

    PubMed

    Ling, Christopher; Hanna, Kevin; Dale, Ann

    2009-08-01

    This article describes a template for implementing an integrated community sustainability plan. The template emphasizes community engagement and outlines the components of a basic framework for integrating ecological, social and economic dynamics into a community plan. The framework is a series of steps that support a sustainable community development process. While it reflects the Canadian experience, the tools and techniques have applied value for a range of environmental planning contexts around the world. The research is case study based and draws from a diverse range of communities representing many types of infrastructure, demographics and ecological and geographical contexts. A critical path for moving local governments to sustainable community development is the creation and implementation of integrated planning approaches. To be effective and to be implemented, a requisite shift to sustainability requires active community engagement processes, political will, and a commitment to political and administrative accountability, and measurement.

  14. A contrast and registration template for magnetic resonance image data guided dental implant placement

    NASA Astrophysics Data System (ADS)

    Eggers, Georg; Cosgarea, Raluca; Rieker, Marcus; Kress, Bodo; Dickhaus, Hartmut; Mühling, Joachim

    2009-02-01

    An oral imaging template was developed to address the shortcomings of MR image data for image guided dental implant planning and placement. The template was conctructed as a gadolinium filled plastic shell to give contrast to the dentition and also to be accurately re-attachable for use in image guided dental implant placement. The result of segmentation and modelling of the dentition from MR Image data with the template was compared to plaster casts of the dentition. In a phantom study dental implant placement was performed based on MR image data. MR imaging with the contrast template allowed complete representation of the existing dentition. In the phantom study, a commercially available system for image guided dental implant placement was used. Transformation of the imaging contrast template into a surgical drill guide based on the MR image data resulted in pilot burr hole placement with an accuracy of 2 mm. MRI based imaging of the existing dentition for proper image guided planning is possible with the proposed template. Using the image data and the template resulted in less accurate pilot burr hole placement in comparison to CT-based image guided implant placement.

  15. Advance care planning in 21st century Australia: a systematic review and appraisal of online advance care directive templates against national framework criteria.

    PubMed

    Luckett, Tim; Bhattarai, Priyanka; Phillips, Jane; Agar, Meera; Currow, David; Krastev, Yordanka; Davidson, Patricia M

    2015-11-01

    A drive to promote advance care planning at a population level has led to a proliferation of online advance care directive (ACD) templates but little information to guide consumer choice. The current study aimed to appraise the quality of online ACD templates promoted for use in Australia. A systematic review of online Australian ACD templates was conducted in February 2014. ACD templates were identified via Google searches, and quality was independently appraised by two reviewers against criteria from the 2011 report A National Frameworkfor Advance Care Directives. Bias either towards or against future medical treatment was assessed using criteria designed to limit subjectivity. Fourteen online ACD templates were included, all of which were available only in English. Templates developed by Southern Cross University best met the framework criteria. One ACD template was found to be biased against medical treatment--the Dying with Dignity Victoria Advance Healthcare Directive. More research is needed to understand how online resources can optimally elicit and record consumers' individual preferences for future care. Future iterations of the framework should address online availability and provide a simple rating system to inform choice and drive quality improvement.

  16. A digital model individual template and CT-guided 125I seed implants for malignant tumors of the head and neck.

    PubMed

    Huang, Ming-Wei; Liu, Shu-Ming; Zheng, Lei; Shi, Yan; Zhang, Jie; Li, Yan-Sheng; Yu, Guang-Yan; Zhang, Jian-Guo

    2012-11-01

    To enhance the accuracy of radioactive seed implants in the head and neck, a digital model individual template, containing information simultaneously on needle pathway and facial features, was designed to guide implantation with CT imaging. Thirty-one patients with recurrent and local advanced malignant tumors of head and neck after prior surgery and radiotherapy were involved in this study. Before (125)I implants, patients received CT scans based on 0.75mm thickness. And the brachytherapy treatment planning system (BTPS) software was used to make the implantation plan based on the CT images. Mimics software and Geomagic software were used to read the data containing CT images and implantation plan, and to design the individual template. Then the individual template containing the information of needle pathway and face features simultaneously was made through rapid prototyping (RP) technique. All patients received (125)I seeds interstitial implantation under the guide of the individual template and CT. The individual templates were positioned easily and accurately, and were stable. After implants, treatment quality evaluation was made by CT and TPS. The seeds and dosages distribution (D(90),V(100),V(150)) were well meet the treatment requirement. Clinical practice confirms that this approach can facilitate easier and more accurate implantation.

  17. Plan to procedure: combining 3D templating with rapid prototyping to enhance pedicle screw placement

    NASA Astrophysics Data System (ADS)

    Augustine, Kurt E.; Stans, Anthony A.; Morris, Jonathan M.; Huddleston, Paul M.; Matsumoto, Jane M.; Holmes, David R., III; Robb, Richard A.

    2010-02-01

    Spinal fusion procedures involving the implantation of pedicle screws have steadily increased over the past decade because of demonstrated improvement in biomechanical stability of the spine. However, current methods of spinal fusion carries a risk of serious vascular, visceral, and neurological injury caused by inaccurate placement or inappropriately sized instrumentation, which may lead to patient paralysis or even fatality. 3D spine templating software developed by the Biomedical Imaging Resource (BIR) at Mayo Clinic allows the surgeon to virtually place pedicle screws using pre-operative 3D CT image data. With the template plan incorporated, a patient-specific 3D anatomic model is produced using a commercial rapid prototyping system. The pre-surgical plan and the patient-specific model then are used in the procedure room to provide real-time visualization and quantitative guidance for accurate placement of each pedicle screw, significantly reducing risk of injury. A pilot study was conducted at Mayo Clinic by the Department of Radiology, the Department of Orthopedics, and the BIR, involving seven complicated pediatric spine cases. In each case, pre-operative 3D templating was carried out and patient specific models were generated. The plans and the models were used intra-operatively, providing precise pedicle screw starting points and trajectories. Postoperative assessment by the surgeon confirmed all seven operations were successful. Results from the study suggest that patient-specific, 3D anatomic models successfully acquired from 3D templating tools are valuable for planning and conducting pedicle screw insertion procedures.

  18. Semi-automated intra-operative fluoroscopy guidance for osteotomy and external-fixator.

    PubMed

    Lin, Hong; Samchukov, Mikhail L; Birch, John G; Cherkashin, Alexander

    2006-01-01

    This paper outlines a semi-automated intra-operative fluoroscopy guidance and monitoring approach for osteotomy and external-fixator application in orthopedic surgery. Intra-operative Guidance module is one component of the "LegPerfect Suite" developed for assisting the surgical correction of lower extremity angular deformity. The Intra-operative Guidance module utilizes information from the preoperative surgical planning module as a guideline to overlay (register) its bone outline semi-automatically with the bone edge from the real-time fluoroscopic C-Arm X-Ray image in the operating room. In the registration process, scaling factor is obtained automatically through matching a fiducial template in the fluoroscopic image and a marker in the module. A triangle metal plate, placed on the operating table is used as fiducial template. The area of template image within the viewing area of the fluoroscopy machine is obtained by the image processing techniques such as edge detection and Hough transformation to extract the template from other objects in the fluoroscopy image. The area of fiducial template from fluoroscopic image is then compared with the area of the marker from the planning so as to obtain the scaling factor. After the scaling factor is obtained, the user can use simple operations by mouse to shift and rotate the preoperative planning to overlay the bone outline from planning with the bone edge from fluoroscopy image. In this way osteotomy levels and external fixator positioning on the limb can guided by the computerized preoperative plan.

  19. Iterations of computer- and template assisted mandibular or maxillary reconstruction with free flaps containing the lateral scapular border--Evolution of a biplanar plug-on cutting guide.

    PubMed

    Cornelius, Carl-Peter; Giessler, Goetz Andreas; Wilde, Frank; Metzger, Marc Christian; Mast, Gerson; Probst, Florian Andreas

    2016-03-01

    Computer-assisted planning and intraoperative implementation using templates have become appreciated modalities in craniofacial reconstruction with fibula and DCIA flaps due to saving in operation time, improved accuracy of osteotomies and easy insetting. Up to now, a similar development for flaps from the subscapular vascular system, namely the lateral scapular border and tip, has not been addressed in the literature. A cohort of 12 patients who underwent mandibular (n = 10) or maxillary (n = 2) reconstruction with free flaps containing the lateral scapular border and tip using computer-assisted planning, stereolithography (STL) models and selective laser sintered (SLS) templates for bone contouring and sub-segmentation osteotomies was reviewed focussing on iterations in the design of computer generated tools and templates. The technical evolution migrated from hybrid STL models over SLS templates for cut out as well as sub-segmentation with a uniplanar framework to plug-on tandem template assemblies providing a biplanar access for the in toto cut out from the posterior aspect in succession with contouring into sub-segments from the medial side. The latest design version is the proof of concept that virtual planning of bone flaps from the lateral scapular border can be successfully transferred into surgery by appropriate templates. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  20. Modular preoperative planning software for computer-aided oral implantology and the application of a novel stereolithographic template: a pilot study.

    PubMed

    Chen, Xiaojun; Yuan, Jianbing; Wang, Chengtao; Huang, Yuanliang; Kang, Lu

    2010-09-01

    In the field of oral implantology, there is a trend toward computer-aided implant surgery, especially the application of computerized tomography (CT)-derived surgical templates. However, because of relatively unsatisfactory match between the templates and receptor sites, conventional surgical templates may not be accurate enough for the severely resorbed edentulous cases during the procedure of transferring the preoperative plan to the actual surgery. The purpose of this study is to introduce a novel bone-tooth-combined-supported surgical guide, which is designed by utilizing a special modular software and fabricated via stereolithography technique using both laser scanning and CT imaging, thus improving the fit accuracy and reliability. A modular preoperative planning software was developed for computer-aided oral implantology. With the introduction of dynamic link libraries and some well-known free, open-source software libraries such as Visualization Toolkit (Kitware, Inc., New York, USA) and Insight Toolkit (Kitware, Inc.) a plug-in evolutive software architecture was established, allowing for expandability, accessibility, and maintainability in our system. To provide a link between the preoperative plan and the actual surgery, a novel bone-tooth-combined-supported surgical template was fabricated, utilizing laser scanning, image registration, and rapid prototyping. Clinical studies were conducted on four partially edentulous cases to make a comparison with the conventional bone-supported templates. The fixation was more stable than tooth-supported templates because laser scanning technology obtained detailed dentition information, which brought about the unique topography between the match surface of the templates and the adjacent teeth. The average distance deviations at the coronal and apical point of the implant were 0.66 mm (range: 0.3-1.2) and 0.86 mm (range: 0.4-1.2), and the average angle deviation was 1.84 degrees (range: 0.6-2.8 degrees ). This pilot study proves that the novel combined-supported templates are superior to the conventional ones. However, more clinical cases will be conducted to demonstrate their feasibility and reliability.

  1. Comparison of five-axis milling and rapid prototyping for implant surgical templates.

    PubMed

    Park, Ji-Man; Yi, Tae-Kyoung; Koak, Jai-Young; Kim, Seong-Kyoon; Park, Eun-Jin; Heo, Seong-Joo

    2014-01-01

    This study aims to compare and evaluate the accuracy of surgical templates fabricated using coordinate synchronization processing with five-axis milling and design-related processing with rapid prototyping (RP). Master phantoms with 10 embedded gutta-percha cylinders hidden under artificial gingiva were fabricated and imaged using cone beam computed tomography. Vectors of the hidden cylinders were extracted and transferred to those of the planned implants through reverse engineering using virtual planning software. An RP-produced template was fabricated by stereolithography in photopolymer at the RP center according to planned data. Metal sleeves were bonded after holes were bored (group RP). For the milled template, milling coordinates were synchronized using the conversion process for the coordinate synchronization platform located on the model's bottom. Metal bushings were set on holes milled on the five-axis milling machine, on which the model was fixed through the coordinate synchronization plate, and the framework was constructed on the model using orthodontic resin (group CS). A computed tomography image was taken with templates firmly fixed on models using anchor pins (RP) or anchor screws (CS). The accuracy was analyzed via reverse engineering. Differences between the two groups were compared by repeated measures two-factor analysis. From the reverse-engineered image of the template on the experimental model, RP-produced templates showed significantly larger deviations than did milled surgical guides. Maximum deviations of the group RP were 1.58 mm (horizontal), 1.68 mm (vertical), and 8.51 degrees (angular); those of the group CS were 0.68 mm (horizontal), 0.41 mm (vertical), and 3.23 degrees (angular). A comparison of milling and RP template production methods showed that a vector-milled surgical guide had significantly smaller deviations than did an RP-produced template. The accuracy of computer-guided milled surgical templates was within the safety margin of previous studies.

  2. Robotic Needle Guide for Prostate Brachytherapy: Clinical Testing of Feasibility and Performance

    PubMed Central

    Song, Danny Y; Burdette, Everette C; Fiene, Jonathan; Armour, Elwood; Kronreif, Gernot; Deguet, Anton; Zhang, Zhe; Iordachita, Iulian; Fichtinger, Gabor; Kazanzides, Peter

    2010-01-01

    Purpose Optimization of prostate brachytherapy is constrained by tissue deflection of needles and fixed spacing of template holes. We developed and clinically tested a robotic guide towards the goal of allowing greater freedom of needle placement. Methods and Materials The robot consists of a small tubular needle guide attached to a robotically controlled arm. The apparatus is mounted and calibrated to operate in the same coordinate frame as a standard template. Translation in x and y directions over the perineum ±40mm are possible. Needle insertion is performed manually. Results Five patients were treated in an IRB-approved study. Confirmatory measurements of robotic movements for initial 3 patients using infrared tracking showed mean error of 0.489 mm (SD 0.328 mm). Fine adjustments in needle positioning were possible when tissue deflection was encountered; adjustments were performed in 54/179 (30.2%) needles placed, with 36/179 (20.1%) adjustments of > 2mm. Twenty-seven insertions were intentionally altered to positions between the standard template grid to improve the dosimetric plan or avoid structures such as pubic bone and blood vessels. Conclusions Robotic needle positioning provided a means of compensating for needle deflections as well as the ability to intentionally place needles into areas between the standard template holes. To our knowledge, these results represent the first clinical testing of such a system. Future work will be incorporation of direct control of the robot by the physician, adding software algorithms to help avoid robot collisions with the ultrasound, and testing the angulation capability in the clinical setting. PMID:20729152

  3. Accuracy of using computer-aided rapid prototyping templates for mandible reconstruction with an iliac crest graft

    PubMed Central

    2014-01-01

    Background This study aimed to evaluate the accuracy of surgical outcomes in free iliac crest mandibular reconstructions that were carried out with virtual surgical plans and rapid prototyping templates. Methods This study evaluated eight patients who underwent mandibular osteotomy and reconstruction with free iliac crest grafts using virtual surgical planning and designed guiding templates. Operations were performed using the prefabricated guiding templates. Postoperative three-dimensional computer models were overlaid and compared with the preoperatively designed models in the same coordinate system. Results Compared to the virtual osteotomy, the mean error of distance of the actual mandibular osteotomy was 2.06 ± 0.86 mm. When compared to the virtual harvested grafts, the mean error volume of the actual harvested grafts was 1412.22 ± 439.24 mm3 (9.12% ± 2.84%). The mean error between the volume of the actual harvested grafts and the shaped grafts was 2094.35 ± 929.12 mm3 (12.40% ± 5.50%). Conclusions The use of computer-aided rapid prototyping templates for virtual surgical planning appears to positively influence the accuracy of mandibular reconstruction. PMID:24957053

  4. Reliability of implant placement after virtual planning of implant positions using cone beam CT data and surgical (guide) templates.

    PubMed

    Nickenig, Hans-Joachim; Eitner, Stephan

    2007-01-01

    We assessed the reliability of implant placement after virtual planning of implant positions using cone-beam CT data and surgical guide templates. A total of 102 patients (250 implants, 55.4% mandibular; mean patient age, 40.4 years) who had undergone implant treatment therapy in an armed forces dental clinic (Cologne, Germany) between July 1, 2005 and December 1, 2005. They were treated with a system that allows transfer of virtual planning to surgical guide templates. Only in eight cases the surgical guides were not used because a delayed implant placement was necessary. In four posterior mandibular cases, handling was limited because of reduced interocclusal distance, requiring 50% shortening of the drill guides. The predictability of implant size was high: only one implant was changed to a smaller diameter (because of insufficient bone). In all cases, critical anatomical structures were protected and no complications were detected in postoperative panoramic radiographs. In 58.1% (147) of the 250 implants, a flapless surgery plan was realized. Implant placement after virtual planning of implant positions using cone beam CT data and surgical templates can be reliable for preoperative assessment of implant size, position, and anatomical complications. It is also indicative of cases amenable to flapless surgery.

  5. Effect of digital template in the assistant of a giant condylar osteochondroma resection.

    PubMed

    Bai, Guo; He, Dongmei; Yang, Chi; Lu, Chuan; Huang, Dong; Chen, Minjie; Yuan, Jianbing

    2014-05-01

    Exostosis osteochondroma is usually resected with the whole condyle even part of it is not involved. This study was to report the effect of using digital template in the assistant of resection while protecting the uninvolved condyle. We used computer-aided design technique in the assistant of making preoperative plan of a patient with giant condylar osteochondroma of exogenous type, including determining the boundary between the tumor and the articular surface of condyle, and designing the virtual tumor resection plane, surgical approach, and remove-out path of the tumor. The digital osteotomy template was made by rapid prototyping technique based on the preoperative plan. Postoperative CT scan was performed and merged with the preoperative CT by the Proplan 1.3 system to evaluate the accuracy of surgical resection with the guide of digital template. The osteotomy template was attached to the lateral surface of condyle accurately, and the tumor was removed totally by the guide of the template without injuries to adjacent nerves and vessels. Postoperative CT showed that the osteochondroma was removed completely and the unaffected articular surface of condyle was preserved well. The merging of postoperative and preoperative CT by Proplan 1.3 system showed the outcome of the operation matched with the preoperative planning quite well with an error of 0.92 mm. There was no sign of recurrence after 6 months of follow-up. The application of digital template could improve the accuracy of the giant condylar tumor resection and help to preserve the uninvolved condyle. The use of digital template could reduce injuries to the nerves and vessels as well as save time for the operation.

  6. Berkeley Lab - Materials Sciences Division

    Science.gov Websites

    ; Finance Templates Travel One-Stop Acknowledging MSD Support Human Resources Facilities & Space Planning Procurement and Property Proposals & Finance Templates Travel Travel This page has been moved

  7. Remedial training for the radiology resident: a template for optimization of the learning plan.

    PubMed

    Mar, Colin; Chang, Silvia; Forster, Bruce

    2015-02-01

    All radiology residency programs should strive for the early identification of individuals in need of remedial training and have an approach ready to address this situation. This article provides a template for a step-by-step approach which is team based. It includes definition of the learning or performance issues, creation of suitable learning objectives and learning plan, facilitation of feedback and assessment, and definition of outcomes. Using such a template will assist the resident in returning to the path toward a safe and competent radiologist. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  8. Transdisciplinary Pedagogical Templates and Their Potential for Adaptive Reuse

    ERIC Educational Resources Information Center

    Dobozy, Eva; Dalziel, James

    2016-01-01

    This article explores the use and usefulness of carefully designed transdisciplinary pedagogical templates (TPTs) aligned to different learning theories. The TPTs are based on the Learning Design Framework outlined in the Larnaca Declaration (Dalziel et al. in this collection). The generation of pedagogical plans or templates is not new. However,…

  9. E3 Charter Template

    EPA Pesticide Factsheets

    This is a charter template which includes decisions made during the project planning phase, as well as local project goals, a communication strategy, an outreach strategy, distribution of responsibilities and a schedule.

  10. Generation and evaluation of an ultra-high-field atlas with applications in DBS planning

    NASA Astrophysics Data System (ADS)

    Wang, Brian T.; Poirier, Stefan; Guo, Ting; Parrent, Andrew G.; Peters, Terry M.; Khan, Ali R.

    2016-03-01

    Purpose Deep brain stimulation (DBS) is a common treatment for Parkinson's disease (PD) and involves the use of brain atlases or intrinsic landmarks to estimate the location of target deep brain structures, such as the subthalamic nucleus (STN) and the globus pallidus pars interna (GPi). However, these structures can be difficult to localize with conventional clinical magnetic resonance imaging (MRI), and thus targeting can be prone to error. Ultra-high-field imaging at 7T has the ability to clearly resolve these structures and thus atlases built with these data have the potential to improve targeting accuracy. Methods T1 and T2-weighted images of 12 healthy control subjects were acquired using a 7T MR scanner. These images were then used with groupwise registration to generate an unbiased average template with T1w and T2w contrast. Deep brain structures were manually labelled in each subject by two raters and rater reliability was assessed. We compared the use of this unbiased atlas with two other methods of atlas-based segmentation (single-template and multi-template) for subthalamic nucleus (STN) segmentation on 7T MRI data. We also applied this atlas to clinical DBS data acquired at 1.5T to evaluate its efficacy for DBS target localization as compared to using a standard atlas. Results The unbiased templates provide superb detail of subcortical structures. Through one-way ANOVA tests, the unbiased template is significantly (p <0.05) more accurate than a single-template in atlas-based segmentation and DBS target localization tasks. Conclusion The generated unbiased averaged templates provide better visualization of deep brain nuclei and an increase in accuracy over single-template and lower field strength atlases.

  11. Enhanced Preoperative Deep Inferior Epigastric Artery Perforator Flap Planning with a 3D-Printed Perforasome Template: Technique and Case Report.

    PubMed

    Chae, Michael P; Hunter-Smith, David J; Rostek, Marie; Smith, Julian A; Rozen, Warren Matthew

    2018-01-01

    Optimizing preoperative planning is widely sought in deep inferior epigastric artery perforator (DIEP) flap surgery. One reason for this is that rates of fat necrosis remain relatively high (up to 35%), and that adjusting flap design by an improved understanding of individual perforasomes and perfusion characteristics may be useful in reducing the risk of fat necrosis. Imaging techniques have substantially improved over the past decade, and with recent advances in 3D printing, an improved demonstration of imaged anatomy has become available. We describe a 3D-printed template that can be used preoperatively to mark out a patient's individualized perforasome for flap planning in DIEP flap surgery. We describe this "perforasome template" technique in a case of a 46-year-old woman undergoing immediate unilateral breast reconstruction with a DIEP flap. Routine preoperative computed tomographic angiography was performed, with open-source software (3D Slicer, Autodesk MeshMixer and Cura) and a desktop 3D printer (Ultimaker 3E) used to create a template used to mark intra-flap, subcutaneous branches of deep inferior epigastric artery (DIEA) perforators on the abdomen. An individualized 3D printed template was used to estimate the size and boundaries of a perforasome and perfusion map. The information was used to aid flap design. We describe a new technique of 3D printing a patient-specific perforasome template that can be used preoperatively to infer perforasomes and aid flap design.

  12. MRI-alone radiation therapy planning for prostate cancer: Automatic fiducial marker detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ghose, Soumya, E-mail: soumya.ghose@case.edu; Mitra, Jhimli; Rivest-Hénault, David

    Purpose: The feasibility of radiation therapy treatment planning using substitute computed tomography (sCT) generated from magnetic resonance images (MRIs) has been demonstrated by a number of research groups. One challenge with an MRI-alone workflow is the accurate identification of intraprostatic gold fiducial markers, which are frequently used for prostate localization prior to each dose delivery fraction. This paper investigates a template-matching approach for the detection of these seeds in MRI. Methods: Two different gradient echo T1 and T2* weighted MRI sequences were acquired from fifteen prostate cancer patients and evaluated for seed detection. For training, seed templates from manual contoursmore » were selected in a spectral clustering manifold learning framework. This aids in clustering “similar” gold fiducial markers together. The marker with the minimum distance to a cluster centroid was selected as the representative template of that cluster during training. During testing, Gaussian mixture modeling followed by a Markovian model was used in automatic detection of the probable candidates. The probable candidates were rigidly registered to the templates identified from spectral clustering, and a similarity metric is computed for ranking and detection. Results: A fiducial detection accuracy of 95% was obtained compared to manual observations. Expert radiation therapist observers were able to correctly identify all three implanted seeds on 11 of the 15 scans (the proposed method correctly identified all seeds on 10 of the 15). Conclusions: An novel automatic framework for gold fiducial marker detection in MRI is proposed and evaluated with detection accuracies comparable to manual detection. When radiation therapists are unable to determine the seed location in MRI, they refer back to the planning CT (only available in the existing clinical framework); similarly, an automatic quality control is built into the automatic software to ensure that all gold seeds are either correctly detected or a warning is raised for further manual intervention.« less

  13. MRI-alone radiation therapy planning for prostate cancer: Automatic fiducial marker detection.

    PubMed

    Ghose, Soumya; Mitra, Jhimli; Rivest-Hénault, David; Fazlollahi, Amir; Stanwell, Peter; Pichler, Peter; Sun, Jidi; Fripp, Jurgen; Greer, Peter B; Dowling, Jason A

    2016-05-01

    The feasibility of radiation therapy treatment planning using substitute computed tomography (sCT) generated from magnetic resonance images (MRIs) has been demonstrated by a number of research groups. One challenge with an MRI-alone workflow is the accurate identification of intraprostatic gold fiducial markers, which are frequently used for prostate localization prior to each dose delivery fraction. This paper investigates a template-matching approach for the detection of these seeds in MRI. Two different gradient echo T1 and T2* weighted MRI sequences were acquired from fifteen prostate cancer patients and evaluated for seed detection. For training, seed templates from manual contours were selected in a spectral clustering manifold learning framework. This aids in clustering "similar" gold fiducial markers together. The marker with the minimum distance to a cluster centroid was selected as the representative template of that cluster during training. During testing, Gaussian mixture modeling followed by a Markovian model was used in automatic detection of the probable candidates. The probable candidates were rigidly registered to the templates identified from spectral clustering, and a similarity metric is computed for ranking and detection. A fiducial detection accuracy of 95% was obtained compared to manual observations. Expert radiation therapist observers were able to correctly identify all three implanted seeds on 11 of the 15 scans (the proposed method correctly identified all seeds on 10 of the 15). An novel automatic framework for gold fiducial marker detection in MRI is proposed and evaluated with detection accuracies comparable to manual detection. When radiation therapists are unable to determine the seed location in MRI, they refer back to the planning CT (only available in the existing clinical framework); similarly, an automatic quality control is built into the automatic software to ensure that all gold seeds are either correctly detected or a warning is raised for further manual intervention.

  14. Accuracy of a Computer-Aided Surgical Simulation (CASS) Protocol for Orthognathic Surgery: A Prospective Multicenter Study

    PubMed Central

    Hsu, Sam Sheng-Pin; Gateno, Jaime; Bell, R. Bryan; Hirsch, David L.; Markiewicz, Michael R.; Teichgraeber, John F.; Zhou, Xiaobo; Xia, James J.

    2012-01-01

    Purpose The purpose of this prospective multicenter study was to assess the accuracy of a computer-aided surgical simulation (CASS) protocol for orthognathic surgery. Materials and Methods The accuracy of the CASS protocol was assessed by comparing planned and postoperative outcomes of 65 consecutive patients enrolled from 3 centers. Computer-generated surgical splints were used for all patients. For the genioplasty, one center utilized computer-generated chin templates to reposition the chin segment only for patients with asymmetry. Standard intraoperative measurements were utilized without the chin templates for the remaining patients. The primary outcome measurements were linear and angular differences for the maxilla, mandible and chin when the planned and postoperative models were registered at the cranium. The secondary outcome measurements were: maxillary dental midline difference between the planned and postoperative positions; and linear and angular differences of the chin segment between the groups with and without the use of the template. The latter was measured when the planned and postoperative models were registered at mandibular body. Statistical analyses were performed, and the accuracy was reported using root mean square deviation (RMSD) and Bland and Altman's method for assessing measurement agreement. Results In the primary outcome measurements, there was no statistically significant difference among the 3 centers for the maxilla and mandible. The largest RMSD was 1.0mm and 1.5° for the maxilla, and 1.1mm and 1.8° for the mandible. For the chin, there was a statistically significant difference between the groups with and without the use of the chin template. The chin template group showed excellent accuracy with largest positional RMSD of 1.0mm and the largest orientational RSMD of 2.2°. However, larger variances were observed in the group not using the chin template. This was significant in anteroposterior and superoinferior directions, as in pitch and yaw orientations. In the secondary outcome measurements, the RMSD of maxillary dental midline positions was 0.9mm. When registered at the body of the mandible, the linear and angular differences of the chin segment between the groups with and without the use of the chin template were consistent with the results found in the primary outcome measurements. Conclusion Using the CASS protocol, the computerized plan can be accurately and consistently transferred to the patient to position the maxilla and mandible at the time of surgery. The computer-generated chin template provides more accuracy in repositioning the chin segment than the intraoperative measurements. PMID:22695016

  15. A Microsoft Project-Based Planning, Tracking, and Management Tool for the National Transonic Facility's Model Changeover Process

    NASA Technical Reports Server (NTRS)

    Vairo, Daniel M.

    1998-01-01

    The removal and installation of sting-mounted wind tunnel models in the National Transonic Facility (NTF) is a multi-task process having a large impact on the annual throughput of the facility. Approximately ten model removal and installation cycles occur annually at the NTF with each cycle requiring slightly over five days to complete. The various tasks of the model changeover process were modeled in Microsoft Project as a template to provide a planning, tracking, and management tool. The template can also be used as a tool to evaluate improvements to this process. This document describes the development of the template and provides step-by-step instructions on its use and as a planning and tracking tool. A secondary role of this document is to provide an overview of the model changeover process and briefly describe the tasks associated with it.

  16. Accuracy Evaluation of a Stereolithographic Surgical Template for Dental Implant Insertion Using 3D Superimposition Protocol.

    PubMed

    Cristache, Corina Marilena; Gurbanescu, Silviu

    2017-01-01

    of this study was to evaluate the accuracy of a stereolithographic template, with sleeve structure incorporated into the design, for computer-guided dental implant insertion in partially edentulous patients. Sixty-five implants were placed in twenty-five consecutive patients with a stereolithographic surgical template. After surgery, digital impression was taken and 3D inaccuracy of implants position at entry point, apex, and angle deviation was measured using an inspection tool software. Mann-Whitney U test was used to compare accuracy between maxillary and mandibular surgical guides. A p value < .05 was considered significant. Mean (and standard deviation) of 3D error at the entry point was 0.798 mm (±0.52), at the implant apex it was 1.17 mm (±0.63), and mean angular deviation was 2.34 (±0.85). A statistically significant reduced 3D error was observed at entry point p = .037, at implant apex p = .008, and also in angular deviation p = .030 in mandible when comparing to maxilla. The surgical template used has proved high accuracy for implant insertion. Within the limitations of the present study, the protocol for comparing a digital file (treatment plan) with postinsertion digital impression may be considered a useful procedure for assessing surgical template accuracy, avoiding radiation exposure, during postoperative CBCT scanning.

  17. Strengthening TB infection control in specialized health facilities in Romania--using a participatory approach.

    PubMed

    Turusbekova, N; Popa, C; Dragos, M; van der Werf, M J; Dinca, I

    2016-02-01

    In 2012, the tuberculosis (TB) notification rate among Romanian TB facility doctors and nurses was 7.2 times higher than in the general population. This indicates that transmission is ongoing inside TB facilities and that TB infection control measures are insufficient. To help prevent nosocomial TB transmission a project was implemented that aimed at providing nationwide tailor-made technical assistance in TB infection control (TB-IC) in TB treatment facilities, including the development of TB infection control plans. The objective of the present article is to describe the implementation of the project and to discuss successes and challenges. The project was an implementation study using two methods of evaluation: (1) a cross sectional questionnaire study; and (2) collection of information, during the training, on challenges related to infection control and to the project implementation. The project team developed a TB facility infection control (TB-IC) plan template, together with the Romanian experts. The template was discussed and agreed upon with the experts at a meeting and thereafter distributed by email to all TB facilities. Afterwards, a training of trainers (TOT) seminar was organized which included the provision of information about different training methods, as well as information about TB-IC. The TOT was followed by training for key TB-IC providers. Information about use of the TB-IC template was gathered through a self-administered questionnaire sent to all participants of the expert meeting and the training (42 people). Additionally, non-systematized discussions were held on broader challenges in TB-IC implementation during the training. Within the project 42 key TB-IC service providers were trained in TB-IC, including 9 who were trained at a TOT seminar. The trainees were specialists working at the national level, such as country TB coordinators, or at the TB facility level: TB doctors, epidemiologists, laboratory specialists and maintenance engineers. Out of 42 key TB-IC service providers who were trained, only eighteen responded to the questionnaire (no reminders were sent). Out of these, 14 had used the TB-IC plan template after the project team disseminated it to them by email. The remaining four TB-IC service providers indicated that they were planning to use the template to develop or update their facility TB-IC plans. Related to the use of TB-IC plan template, the following broader challenges in TB-IC were identified: a lack of authority of the individuals responsible for TB-IC to implement the TB-IC measures, lack of training among facility epidemiologists on TB, underdeveloped system for reporting TB in healthcare workers, difficulties with triage of the TB suspects, and poor facility infrastructure hampering implementation of TB-IC measures. Implementing TB-IC plans in Romanian health care facilities proved to be challenging, mainly due to the fact that the national infection control plan for TB was not yet adopted at the time of project implementation, and therefore there was neither a regulatory framework to support TB facility-IC planning nor any related budget allocations for the implementation of the facilities' TB-IC plans. Nonetheless, most respondents who answered the questionnaire (18 of 42 responded) indicated that they had started using the TB-IC plan template, which represents a full package of infection control measures that, when implemented effectively and in its entirety, may be expected to reduce nosocomial transmission. The study's limitations are: very low survey response rate, thus there is a likelihood of responder bias. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. Guided endodontics: accuracy of a novel method for guided access cavity preparation and root canal location.

    PubMed

    Zehnder, M S; Connert, T; Weiger, R; Krastl, G; Kühl, S

    2016-10-01

    To present a novel method utilizing 3D printed templates to gain guided access to root canals and to evaluate its accuracy in vitro. Sixty extracted human teeth were placed into six maxillary jaw models. Preoperative CBCT scans were matched with intra-oral scans using the coDiagnostix(™) software. Access cavities, sleeves and templates for guidance were virtually planned. Templates were produced by a 3D printer. After access cavity preparation by two operators, a postoperative CBCT scan was superimposed on the virtual planning. Accuracy was measured by calculating the deviation of planned and prepared cavities in three dimensions and angle. Ninety-five per cent confidence intervals were calculated for both operators. All root canals were accessible after cavity preparation with 'Guided Endodontics'. Deviations of planned and prepared access cavities were low with means ranging from 0.16 to 0.21 mm for different aspects at the base of the bur and 0.17-0.47 mm at the tip of the bur. Mean of angle deviation was 1.81°. Overlapping 95% confidence intervals revealed no significant difference between operators. 'Guided Endodontics' allowed an accurate access cavity preparation up to the apical third of the root utilizing printed templates for guidance. All root canals were accessible after preparation. © 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  19. Chloropicrin Fumigant Management Plan Phase 2 Templates

    EPA Pesticide Factsheets

    These forms provide a framework for detailing the FMP elements of pesticide products containing the active ingredient chloropicrin, including application block, buffer zones, emergency response plan, tarp plan, soil conditions, and air monitoring.

  20. Options in virtual 3D, optical-impression-based planning of dental implants.

    PubMed

    Reich, Sven; Kern, Thomas; Ritter, Lutz

    2014-01-01

    If a 3D radiograph, which in today's dentistry often consists of a CBCT dataset, is available for computerized implant planning, the 3D planning should also consider functional prosthetic aspects. In a conventional workflow, the CBCT is done with a specially produced radiopaque prosthetic setup that makes the desired prosthetic situation visible during virtual implant planning. If an exclusively digital workflow is chosen, intraoral digital impressions are taken. On these digital models, the desired prosthetic suprastructures are designed. The entire datasets are virtually superimposed by a "registration" process on the corresponding structures (teeth) in the CBCTs. Thus, both the osseous and prosthetic structures are visible in one single 3D application and make it possible to consider surgical and prosthetic aspects. After having determined the implant positions on the computer screen, a drilling template is designed digitally. According to this design (CAD), a template is printed or milled in CAM process. This template is the first physically extant product in the entire workflow. The article discusses the options and limitations of this workflow.

  1. 78 FR 67218 - Agency Information Collection Activities: Company-Run Annual Stress Test Reporting Template and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-08

    ... Activities: Company-Run Annual Stress Test Reporting Template and Documentation for Covered Institutions With... titled, ``Company-Run Annual Stress Test Reporting Template and Documentation for Covered Institutions... under News and Issuances ( http://www.occ.treas.gov/tools-forms/forms/bank-operations/stress-test...

  2. Accuracy of a computer-aided surgical simulation protocol for orthognathic surgery: a prospective multicenter study.

    PubMed

    Hsu, Sam Sheng-Pin; Gateno, Jaime; Bell, R Bryan; Hirsch, David L; Markiewicz, Michael R; Teichgraeber, John F; Zhou, Xiaobo; Xia, James J

    2013-01-01

    The purpose of this prospective multicenter study was to assess the accuracy of a computer-aided surgical simulation (CASS) protocol for orthognathic surgery. The accuracy of the CASS protocol was assessed by comparing planned outcomes with postoperative outcomes of 65 consecutive patients enrolled from 3 centers. Computer-generated surgical splints were used for all patients. For the genioplasty, 1 center used computer-generated chin templates to reposition the chin segment only for patients with asymmetry. Standard intraoperative measurements were used without the chin templates for the remaining patients. The primary outcome measurements were the linear and angular differences for the maxilla, mandible, and chin when the planned and postoperative models were registered at the cranium. The secondary outcome measurements were the maxillary dental midline difference between the planned and postoperative positions and the linear and angular differences of the chin segment between the groups with and without the use of the template. The latter were measured when the planned and postoperative models were registered at the mandibular body. Statistical analyses were performed, and the accuracy was reported using root mean square deviation (RMSD) and the Bland-Altman method for assessing measurement agreement. In the primary outcome measurements, there was no statistically significant difference among the 3 centers for the maxilla and mandible. The largest RMSDs were 1.0 mm and 1.5° for the maxilla and 1.1 mm and 1.8° for the mandible. For the chin, there was a statistically significant difference between the groups with and without the use of the chin template. The chin template group showed excellent accuracy, with the largest positional RMSD of 1.0 mm and the largest orientation RMSD of 2.2°. However, larger variances were observed in the group not using the chin template. This was significant in the anteroposterior and superoinferior directions and the in pitch and yaw orientations. In the secondary outcome measurements, the RMSD of the maxillary dental midline positions was 0.9 mm. When registered at the body of the mandible, the linear and angular differences of the chin segment between the groups with and without the use of the chin template were consistent with the results found in the primary outcome measurements. Using this computer-aided surgical simulation protocol, the computerized plan can be transferred accurately and consistently to the patient to position the maxilla and mandible at the time of surgery. The computer-generated chin template provides greater accuracy in repositioning the chin segment than the intraoperative measurements. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  3. Enhanced Preoperative Deep Inferior Epigastric Artery Perforator Flap Planning with a 3D-Printed Perforasome Template: Technique and Case Report

    PubMed Central

    Hunter-Smith, David J.; Rostek, Marie; Smith, Julian A.; Rozen, Warren Matthew

    2018-01-01

    Summary: Optimizing preoperative planning is widely sought in deep inferior epigastric artery perforator (DIEP) flap surgery. One reason for this is that rates of fat necrosis remain relatively high (up to 35%), and that adjusting flap design by an improved understanding of individual perforasomes and perfusion characteristics may be useful in reducing the risk of fat necrosis. Imaging techniques have substantially improved over the past decade, and with recent advances in 3D printing, an improved demonstration of imaged anatomy has become available. We describe a 3D-printed template that can be used preoperatively to mark out a patient’s individualized perforasome for flap planning in DIEP flap surgery. We describe this “perforasome template” technique in a case of a 46-year-old woman undergoing immediate unilateral breast reconstruction with a DIEP flap. Routine preoperative computed tomographic angiography was performed, with open-source software (3D Slicer, Autodesk MeshMixer and Cura) and a desktop 3D printer (Ultimaker 3E) used to create a template used to mark intra-flap, subcutaneous branches of deep inferior epigastric artery (DIEA) perforators on the abdomen. An individualized 3D printed template was used to estimate the size and boundaries of a perforasome and perfusion map. The information was used to aid flap design. We describe a new technique of 3D printing a patient-specific perforasome template that can be used preoperatively to infer perforasomes and aid flap design. PMID:29464169

  4. Chloropicrin and 1,3-D Fumigant Management Plan Phase 2 Templates

    EPA Pesticide Factsheets

    Plans for soil fumigant pesticide products that contain chloropicrin or 1,3-dichloropropene should include application block information, tarp plan, sign posting for treated area and buffer zone, and other requirements.

  5. Rethinking the Educator Portfolio: An Innovative Criteria-Based Model.

    PubMed

    Shinkai, Kanade; Chen, Chen Amy; Schwartz, Brian S; Loeser, Helen; Ashe, Cynthia; Irby, David M

    2017-11-07

    Academic medical centers struggle to achieve parity in advancement and promotions between educators and discovery-oriented researchers in part because of narrow definitions of scholarship, lack of clear criteria for measuring excellence, and barriers to making educational contributions available for peer review. Despite recent progress in expanding scholarship definitions and identifying excellence criteria, these advances are not integrated into educator portfolio (EP) templates or curriculum vitae platforms. From 2013 to 2015, a working group from the Academy of Medical Educators (AME) at the University of California, San Francisco (UCSF) designed a streamlined, criteria-based EP (EP 2.0) template highlighting faculty members' recent activities in education and setting rigorous evaluation methods to enable educational scholarship to be objectively evaluated for academic advancement, AME membership, and professional development. The EP 2.0 template was integrated into the AME application, resulting in high overall satisfaction among candidates and the selection committee and positive feedback on the template's transparency, ease of use, and streamlined format. In 2016, the EP 2.0 template was integrated into the campus-wide curriculum vitae platform and academic advancement system. The authors plan to increase awareness of the EP 2.0 template by educating promotions committees and faculty at UCSF and partnering with other institutions to disseminate it for use. They also plan to study the impact of the template on supporting educators by making their important scholarly contributions available for peer review, providing guidance for professional development, and decreasing disparities in promotions.

  6. Computer-designed surgical guide template compared with free-hand operation for mesiodens extraction in premaxilla using “trapdoor” method

    PubMed Central

    Hu, Ying Kai; Xie, Qian Yang; Yang, Chi; Xu, Guang Zhou

    2017-01-01

    Abstract The aim of this study was to introduce a novel method of mesiodens extraction using a vascularized pedicled bone flap by piezosurgery and to compare the differences between a computer-aided design surgical guide template and free-hand operation. A total of 8 patients with mesiodens, 4 with a surgical guide (group I), and 4 without it (group II) were included in the study. The surgical design was to construct a trapdoor pedicle on the superior mucoperiosteal attachment with application of piezosurgery. The bone lid was repositioned after mesiodens extraction. Group I patients underwent surgeries based on the preoperative planning with surgical guide templates, while group II patients underwent free-hand operation. The outcome variables were success rate, intraoperative time, anterior nasal spine (ANS) position, changes of nasolabial angle (NLA), and major complications. Data from the 2 groups were compared by SPSS 17.0, using Wilcoxon test. The operative time was significantly shorter in group I patients. All the mesiodentes were extracted successfully and no obvious differences of preoperative and postoperative ANS position and NLA value were found in both groups. The patients were all recovered uneventfully. Surgical guide templates can enhance clinical accuracy and reduce operative time by facilitating accurate osteotomies. PMID:28658139

  7. A semi-automatic computer-aided method for surgical template design

    NASA Astrophysics Data System (ADS)

    Chen, Xiaojun; Xu, Lu; Yang, Yue; Egger, Jan

    2016-02-01

    This paper presents a generalized integrated framework of semi-automatic surgical template design. Several algorithms were implemented including the mesh segmentation, offset surface generation, collision detection, ruled surface generation, etc., and a special software named TemDesigner was developed. With a simple user interface, a customized template can be semi- automatically designed according to the preoperative plan. Firstly, mesh segmentation with signed scalar of vertex is utilized to partition the inner surface from the input surface mesh based on the indicated point loop. Then, the offset surface of the inner surface is obtained through contouring the distance field of the inner surface, and segmented to generate the outer surface. Ruled surface is employed to connect inner and outer surfaces. Finally, drilling tubes are generated according to the preoperative plan through collision detection and merging. It has been applied to the template design for various kinds of surgeries, including oral implantology, cervical pedicle screw insertion, iliosacral screw insertion and osteotomy, demonstrating the efficiency, functionality and generality of our method.

  8. A semi-automatic computer-aided method for surgical template design

    PubMed Central

    Chen, Xiaojun; Xu, Lu; Yang, Yue; Egger, Jan

    2016-01-01

    This paper presents a generalized integrated framework of semi-automatic surgical template design. Several algorithms were implemented including the mesh segmentation, offset surface generation, collision detection, ruled surface generation, etc., and a special software named TemDesigner was developed. With a simple user interface, a customized template can be semi- automatically designed according to the preoperative plan. Firstly, mesh segmentation with signed scalar of vertex is utilized to partition the inner surface from the input surface mesh based on the indicated point loop. Then, the offset surface of the inner surface is obtained through contouring the distance field of the inner surface, and segmented to generate the outer surface. Ruled surface is employed to connect inner and outer surfaces. Finally, drilling tubes are generated according to the preoperative plan through collision detection and merging. It has been applied to the template design for various kinds of surgeries, including oral implantology, cervical pedicle screw insertion, iliosacral screw insertion and osteotomy, demonstrating the efficiency, functionality and generality of our method. PMID:26843434

  9. A semi-automatic computer-aided method for surgical template design.

    PubMed

    Chen, Xiaojun; Xu, Lu; Yang, Yue; Egger, Jan

    2016-02-04

    This paper presents a generalized integrated framework of semi-automatic surgical template design. Several algorithms were implemented including the mesh segmentation, offset surface generation, collision detection, ruled surface generation, etc., and a special software named TemDesigner was developed. With a simple user interface, a customized template can be semi- automatically designed according to the preoperative plan. Firstly, mesh segmentation with signed scalar of vertex is utilized to partition the inner surface from the input surface mesh based on the indicated point loop. Then, the offset surface of the inner surface is obtained through contouring the distance field of the inner surface, and segmented to generate the outer surface. Ruled surface is employed to connect inner and outer surfaces. Finally, drilling tubes are generated according to the preoperative plan through collision detection and merging. It has been applied to the template design for various kinds of surgeries, including oral implantology, cervical pedicle screw insertion, iliosacral screw insertion and osteotomy, demonstrating the efficiency, functionality and generality of our method.

  10. 77 FR 70435 - Agency Information Collection Activities: Proposed Information Collection; Submission for OMB Review

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-26

    ... soliciting comment concerning its information collection titled, ``Annual Stress Test Reporting Template and... submitting comments. Email: [email protected] . Include ``Annual Stress Test Reporting Template and... on the following new proposed information collection: Annual Stress Test Reporting Template and...

  11. Developing a Strategic Plan for Transitioning to Healthcare Knowledge Services Centers (HKSCs)

    PubMed Central

    Goldstein, H. Mark; Coletti, Margaret H.

    2012-01-01

    Facing a negative trend in the form of downsizing, layoffs, and closures, a small committee of hospital librarians in New England was formed in 2004 to provide library advocacy. Between 2008 and 2010, 23 hospital libraries closed in New England. In 2010, the committee shifted its focus from advocacy to a platform for change. This resulted in the creation of the Healthcare Knowledge Services Center (HKSC) Template. The Template is the basis for a 3-phased, 5-year strategic plan to establish several regional pilots, transitioning traditional hospital libraries to healthcare knowledge services centers. This article focuses on Phase One of the strategic plan, Development. PMID:23125551

  12. Accuracy of virtual surgical planning in two-jaw orthognathic surgery: comparison of planned and actual results.

    PubMed

    Zhang, Nan; Liu, Shuguang; Hu, Zhiai; Hu, Jing; Zhu, Songsong; Li, Yunfeng

    2016-08-01

    This study aims to evaluate the accuracy of virtual surgical planning in two-jaw orthognathic surgery via quantitative comparison of preoperative planned and postoperative actual skull models. Thirty consecutive patients who required two-jaw orthognathic surgery were included. A composite skull model was reconstructed by using Digital Imaging and Communications in Medicine (DICOM) data from spiral computed tomography (CT) and STL (stereolithography) data from surface scanning of the dental arch. LeFort I osteotomy of the maxilla and bilateral sagittal split ramus osteotomy (of the mandible were simulated by using Dolphin Imaging 11.7 Premium (Dolphin Imaging and Management Solutions, Chatsworth, CA). Genioplasty was performed, if indicated. The virtual plan was then transferred to the operation room by using three-dimensional (3-D)-printed surgical templates. Linear and angular differences between virtually simulated and postoperative skull models were evaluated. The virtual surgical planning was successfully transferred to actual surgery with the help of 3-D-printed surgical templates. All patients were satisfied with the postoperative facial profile and occlusion. The overall mean linear difference was 0.81 mm (0.71 mm for the maxilla and 0.91 mm for the mandible); and the overall mean angular difference was 0.95 degrees. Virtual surgical planning and 3-D-printed surgical templates facilitated the diagnosis, treatment planning, and accurate repositioning of bony segments in two-jaw orthognathic surgery. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. Micro-stereotactic frame utilizing bone cement for individual fabrication: an initial investigation of its accuracy

    NASA Astrophysics Data System (ADS)

    Rau, Thomas S.; Lexow, G. Jakob; Blume, Denise; Kluge, Marcel; Lenarz, Thomas; Majdani, Omid

    2017-03-01

    A new method for template-guided cochlear implantation surgery is proposed which has been developed to create a minimally invasive access to the inner ear. A first design of the surgical template was drafted, built, and finally tested regarding its accuracy. For individual finalization of the micro-stereotactic frame bone cement is utilized as this well-known and well-established material suggests ease of use as well as high clinical acceptance and enables both sterile and rapid handling. The new concept includes an alignment device, based on a passive hexapod with manually adjustable legs for temporary fixation of the separate parts in the patient-specific pose until the bone cement is spread and finally cured. Additionally, a corresponding evaluation method was developed to determine the accuracy of the microstereotactic frame in some initial experiments. In total 18 samples of the surgical template were fabricated based on previously planned trajectories. The mean positioning error at the target point was 0.30 mm with a standard deviation of 0.25 mm.

  14. 78 FR 16263 - Agency Information Collection Activities; Proposed Information Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-14

    ... collection titled, ``Annual Stress Test Reporting Template and Documentation for Covered Banks with [email protected] . Include ``Annual Stress Test Reporting Template and Documentation for Covered Banks with...: Annual Stress Test Reporting Template and Documentation for Covered Banks With Total Consolidated Assets...

  15. 78 FR 63470 - Agency Information Collection Activities: Proposed Information Collection; Submission for OMB Review

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-24

    ... information collection titled, ``Annual Stress Test Reporting Template and Documentation for Covered Banks.... Email: [email protected] . Include ``Annual Stress Test Reporting Template and Documentation'' on the... information collection: Annual Stress Test Reporting Template and Documentation for Covered Banks With Total...

  16. Companion Guides for Lesson Planning: A Planning Template and the Lesson Plan Pro Forma

    ERIC Educational Resources Information Center

    Pang, May

    2016-01-01

    Jason Anderson's proposal, in "ELT Journal" (2015), for an affordance-based approach to lesson planning raises important issues in teacher education. However, his arguments against the role of planned outcomes in favour of an affordance-based focus using learning opportunities as units of planning fail to acknowledge the complexities…

  17. Multicriteria plan optimization in the hands of physicians: a pilot study in prostate cancer and brain tumors.

    PubMed

    Müller, Birgit S; Shih, Helen A; Efstathiou, Jason A; Bortfeld, Thomas; Craft, David

    2017-11-06

    The purpose of this study was to demonstrate the feasibility of physician driven planning in intensity modulated radiotherapy (IMRT) with a multicriteria optimization (MCO) treatment planning system and template based plan optimization. Exploiting the full planning potential of MCO navigation, this alternative planning approach intends to improve planning efficiency and individual plan quality. Planning was retrospectively performed on 12 brain tumor and 10 post-prostatectomy prostate patients previously treated with MCO-IMRT. For each patient, physicians were provided with a template-based generated Pareto surface of optimal plans to navigate, using the beam angles from the original clinical plans. We compared physician generated plans to clinically delivered plans (created by dosimetrists) in terms of dosimetric differences, physician preferences and planning times. Plan qualities were similar, however physician generated and clinical plans differed in the prioritization of clinical goals. Physician derived prostate plans showed significantly better sparing of the high dose rectum and bladder regions (p(D1) < 0.05; D1: dose received by 1% of the corresponding structure). Physicians' brain tumor plans indicated higher doses for targets and brainstem (p(D1) < 0.05). Within blinded plan comparisons physicians preferred the clinical plans more often (brain: 6:3 out of 12, prostate: 2:6 out of 10) (not statistically significant). While times of physician involvement were comparable for prostate planning, the new workflow reduced the average involved time for brain cases by 30%. Planner times were reduced for all cases. Subjective benefits, such as a better understanding of planning situations, were observed by clinicians through the insight into plan optimization and experiencing dosimetric trade-offs. We introduce physician driven planning with MCO for brain and prostate tumors as a feasible planning workflow. The proposed approach standardizes the planning process by utilizing site specific templates and integrates physicians more tightly into treatment planning. Physicians' navigated plan qualities were comparable to the clinical plans. Given the reduction of planning time of the planner and the equal or lower planning time of physicians, this approach has the potential to improve departmental efficiencies.

  18. Berkeley Lab - Materials Sciences Division

    Science.gov Websites

    MSD Support Human Resources Facilities & Space Planning Procurement and Property Proposals & Planning Procurement and Property Proposals & Finance Templates Travel Procurement and Property This

  19. Automated construction of an intraoperative high-dose-rate treatment plan library for the Varian brachytherapy treatment planning system.

    PubMed

    Deufel, Christopher L; Furutani, Keith M; Dahl, Robert A; Haddock, Michael G

    2016-01-01

    The ability to create treatment plans for intraoperative high-dose-rate (IOHDR) brachytherapy is limited by lack of imaging and time constraints. An automated method for creation of a library of high-dose-rate brachytherapy plans that can be used with standard planar applicators in the intraoperative setting is highly desirable. Nonnegative least squares algebraic methods were used to identify dwell time values for flat, rectangular planar applicators. The planar applicators ranged in length and width from 2 cm to 25 cm. Plans were optimized to deliver an absorbed dose of 10 Gy to three different depths from the patient surface: 0 cm, 0.5 cm, and 1.0 cm. Software was written to calculate the optimized dwell times and insert dwell times and positions into a .XML plan template that can be imported into the Varian brachytherapy treatment planning system. The user may import the .XML template into the treatment planning system in the intraoperative setting to match the patient applicator size and prescribed treatment depth. A total of 1587 library plans were created for IOHDR brachytherapy. Median plan generation time was approximately 1 minute per plan. Plan dose was typically 100% ± 1% (mean, standard deviation) of the prescribed dose over the entire length and width of the applicator. Plan uniformity was best for prescription depths of 0 cm and 0.5 cm from the patient surface. An IOHDR plan library may be created using automated methods. Thousands of plan templates may be optimized and prepared in a few hours to accommodate different applicator sizes and treatment depths and reduce treatment planning time. The automated method also enforces dwell time symmetry for symmetrical applicator geometries, which simplifies quality assurance. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  20. Stereolithographic Surgical Template: A Review

    PubMed Central

    Dandekeri, Shilpa Sudesh; Sowmya, M.K.; Bhandary, Shruthi

    2013-01-01

    Implant placement has become a routine modality of dental care.Improvements in surgical reconstructive methods as well as increased prosthetic demands,require a highly accurate diagnosis, planning and placement. Recently,computer-aided design and manufacturing have made it possible to use data from computerised tomography to not only plan implant rehabilitation,but also transfer this information to the surgery.A review on one of this technique called Stereolithography is presented in this article.It permits graphic and complex 3D implant placement and fabrication of stereolithographic surgical templates. Also offers many significant benefits over traditional procedures. PMID:24179955

  1. Lesson Plans: Road Maps for the Active Learning Classroom.

    PubMed

    Moore-Cox, Annie

    2017-11-01

    Lesson planning is a documentation process used extensively in education from kindergarten through 12th grade, but rarely in higher education, including undergraduate, prelicensure nursing education. Lesson plans help teachers plan what will happen during a class period from moment to moment. Trends in nursing education, such as the incorporation of active learning strategies in the classroom, make lesson plans a timely addition to the nurse educator's toolkit. This article describes the components of a lesson plan and offers an author-developed template for use in nursing education. Using the template helps nurse educators map out activities for all class participants, such as students, student pairs and teams, and faculty. The lesson plan enables faculty to plot out the many dynamic components of an active learning class period. It also serves as a road map for subsequent faculty, which is an important feature as the profession faces a wave of retirements in the coming decade. [J Nurs Educ. 2017;56(11):697-700.]. Copyright 2017, SLACK Incorporated.

  2. Introduction to Sample Plan Package for Farms

    EPA Pesticide Factsheets

    An example of a completed and self-certified Tier I Qualified Facility SPCC Plan using the template found in Appendix G of the SPCC rule (40 CFR part 112). This example illustrates how to develop an SPCC Plan using a farm scenario.

  3. A report template for molecular genetic tests designed to improve communication between the clinician and laboratory.

    PubMed

    Scheuner, Maren T; Hilborne, Lee; Brown, Julie; Lubin, Ira M

    2012-07-01

    Errors are most likely to occur during the pre- and postanalytic phases of the genetic testing process, which can contribute to underuse, overuse, and misuse of genetic tests. To mitigate these errors, we created a template for molecular genetic test reports that utilizes the combined features of synoptic reporting and narrative interpretation. A variation of the Delphi consensus process with an expert panel was used to create a draft report template, which was further informed by focus group discussions with primary care physicians. There was agreement that molecular genetic test reports should present information in groupings that flow in a logical manner, and most participants preferred the following order of presentation: patient and physician information, test performed, test results and interpretation, guidance on next steps, and supplemental information. We define data elements for the report as "required," "optional," "possible," and "not necessary"; provide recommendations regarding the grouping of these data elements; and describe the ideal design of the report template, including the preferred order of the report sections, formatting of data, and length of the report. With input from key stakeholders and building upon prior work, we created a template for molecular genetic test reports designed to improve clinical decision making at the point of care. The template design should lead to more effective communication between the laboratory and ordering clinician. Studies are needed to assess the usefulness and effectiveness of molecular genetic test reports generated using this template.

  4. Introduction to Soil Fumigant Management Plans

    EPA Pesticide Factsheets

    Soil fumigant pesticide labels require users to prepare a site-specific fumigation management plan (FMP) before the application begins. EPA has developed templates that outline the elements required by the labels.

  5. [Characteristics of supramolecular imprinting template on liver meridian tropism of traditional Chinese medicine based on molecular connectivity index].

    PubMed

    Fan, Shi-Qi; Li, Sen; Liu, Jin-Ling; Yang, Jiao; Hu, Chao; Zhu, Jun-Ping; Xiao, Xiao-Qin; Liu, Wen-Long; He, Fu-Yuan

    2017-01-01

    The molecular connectivity index was adopted to explore the characteristics of supramolecular imprinting template of herbs distributed to liver meridian, in order to provide scientific basis for traditional Chinese medicines(TCMs) distributed to liver meridian. In this paper, with "12th five-year plan" national planning textbooks Science of Traditional Chinese Medicine and Chemistry of Traditional Chinese Medicine as the blueprint, literatures and TCMSP sub-databases in TCM pharmacology of northwest science and technology university of agriculture and forestry were retrieved to collect and summarize active constituents of TCM distributed to liver meridian, and calculate the molecular connectivity index. The average molecular connectivity index of ingredients distributed to liver meridian was 9.47, which was close to flavonoid glycosides' (9.17±2.11) and terpenes (9.30±3.62). Therefore, it is inferred that template molecule of liver meridian is similar to physicochemical property of flavonoid glycosides and terpenes, which could be best matched with imprinting template of liver meridian. Copyright© by the Chinese Pharmaceutical Association.

  6. Multiple template-based fluoroscopic tracking of lung tumor mass without implanted fiducial markers

    NASA Astrophysics Data System (ADS)

    Cui, Ying; Dy, Jennifer G.; Sharp, Gregory C.; Alexander, Brian; Jiang, Steve B.

    2007-10-01

    Precise lung tumor localization in real time is particularly important for some motion management techniques, such as respiratory gating or beam tracking with a dynamic multi-leaf collimator, due to the reduced clinical tumor volume (CTV) to planning target volume (PTV) margin and/or the escalated dose. There might be large uncertainties in deriving tumor position from external respiratory surrogates. While tracking implanted fiducial markers has sufficient accuracy, this procedure may not be widely accepted due to the risk of pneumothorax. Previously, we have developed a technique to generate gating signals from fluoroscopic images without implanted fiducial markers using a template matching method (Berbeco et al 2005 Phys. Med. Biol. 50 4481-90, Cui et al 2007 Phys. Med. Biol. 52 741-55). In this paper, we present an extension of this method to multiple-template matching for directly tracking the lung tumor mass in fluoroscopy video. The basic idea is as follows: (i) during the patient setup session, a pair of orthogonal fluoroscopic image sequences are taken and processed off-line to generate a set of reference templates that correspond to different breathing phases and tumor positions; (ii) during treatment delivery, fluoroscopic images are continuously acquired and processed; (iii) the similarity between each reference template and the processed incoming image is calculated; (iv) the tumor position in the incoming image is then estimated by combining the tumor centroid coordinates in reference templates with proper weights based on the measured similarities. With different handling of image processing and similarity calculation, two such multiple-template tracking techniques have been developed: one based on motion-enhanced templates and Pearson's correlation score while the other based on eigen templates and mean-squared error. The developed techniques have been tested on six sequences of fluoroscopic images from six lung cancer patients against the reference tumor positions manually determined by a radiation oncologist. The tumor centroid coordinates automatically detected using both methods agree well with the manually marked reference locations. The eigenspace tracking method performs slightly better than the motion-enhanced method, with average localization errors less than 2 pixels (1 mm) and the error at a 95% confidence level of about 2-4 pixels (1-2 mm). This work demonstrates the feasibility of direct tracking of a lung tumor mass in fluoroscopic images without implanted fiducial markers using multiple reference templates.

  7. Ward round template: enhancing patient safety on ward rounds.

    PubMed

    Gilliland, Niall; Catherwood, Natalie; Chen, Shaouyn; Browne, Peter; Wilson, Jacob; Burden, Helena

    2018-01-01

    Concerns had been raised at clinical governance regarding the safety of our inpatient ward rounds with particular reference to: documentation of clinical observations and National Early Warning Score (NEWS), compliance with Trust guidance for venous thromboembolism (VTE) risk assessment, antibiotic stewardship, palliative care and treatment escalation plans (TEP). This quality improvement project was conceived to ensure these parameters were considered and documented during the ward round, thereby improving patient care and safety. These parameters were based on Trust patient safety guidance and CQUIN targets. The quality improvement technique of plan-do-study-act (PDSA) was used in this project. We retrospectively reviewed ward round entries to record baseline measurements, based on the above described parameters, prior to making any changes. Following this, the change applied was the introduction of a ward round template to include the highlighted important baseline parameters. Monthly PDSA cycles are performed, and baseline measurements are re-examined, then relevant changes were made to the ward round template. Documentation of baseline measurements was poor prior to introduction of the ward round template; this improved significantly following introduction of a standardised ward round template. Following three cycles, documentation of VTE risk assessments increased from 14% to 92%. Antibiotic stewardship documentation went from 0% to 100%. Use of the TEP form went from 29% to 78%. Following introduction of the ward round template, compliance improved significantly in all safety parameters. Important safety measures being discussed on ward rounds will lead to enhanced patient safety and will improve compliance to Trust guidance and comissioning for quality and innovation (CQUIN) targets. Ongoing change implementation will focus on improving compliance with usage of the template on all urology ward rounds.

  8. Template-directed instrumentation in total knee arthroplasty: cost savings analysis.

    PubMed

    Hsu, Andrew R; Gross, Christopher E; Bhatia, Sanjeev; Levine, Brett R

    2012-11-01

    The use of digital radiography and templating software in total knee arthroplasty (TKA) continues to become more prevalent as the number of procedures performed increases every year. Template-directed instrumentation (TDI) is a novel approach to surgical planning that combines digital templating with limited intraoperative instruments. The purpose of this study was to evaluate the financial implications and radiographic outcomes of using TDI to direct instrumentation during primary TKA. Over a 1-year period, 82 consecutive TKAs using TDI were retrospectively reviewed. Patient demographics and preoperative templated sizes of predicted components were recorded, and OrthoView digital planning software (OrthoView LLC, Jacksonville, Florida was used to determine the 2 most likely tibial and femoral component sizes for each case. This sizing information was used to direct component vendors to prepare 3 lightweight instrument trays based on these sizes. The sizes of implanted components and the number of total trays required were documented. A cost savings analysis was performed to compare TDI and non-TDI surgical expenses for TKA. In 80 (97%) of 82 cases, the prepared sizes determined by TDI using 3 instrument trays were sufficient. Preoperative templating correctly predicted the size of the tibial and femoral component sizes in 90% and 83% of cases, respectively. The average number of trays used with TDI was 3.0 (range, 3-5 trays) compared with 7.5 (range, 6-9 trays) used in 82 preceding non-TDI TKAs. Based on standard fees to sterilize and package implant trays (approximately $26 based on a survey of 10 orthopedic hospitals performing TKA), approximately $9612 was saved by using TDI over the 1-year study period. Overall, digital templating and TDI were a simple and cost-effective approach when performing primary TKA. Copyright 2012, SLACK Incorporated.

  9. Effective communication of molecular genetic test results to primary care providers.

    PubMed

    Scheuner, Maren T; Edelen, Maria Orlando; Hilborne, Lee H; Lubin, Ira M

    2013-06-01

    We evaluated a template for molecular genetic test reports that was developed as a strategy to reduce communication errors between the laboratory and ordering clinician. We surveyed 1,600 primary care physicians to assess satisfaction, ease of use, and effectiveness of genetic test reports developed using our template and reports developed by clinical laboratories. Mean score differences of responses between the reports were compared using t-tests. Two-way analysis of variance evaluated the effect of template versus standard reports and the influence of physician characteristics. There were 396 (24%) respondents. Template reports had higher scores than the standard reports for each survey item. The gender and specialty of the physician did not influence scores; however, younger physicians gave higher scores regardless of report type. There was significant interaction between report type and whether physicians ordered or reviewed any genetic tests (none versus at least one) in the past year, P = 0.005. For each survey item assessing satisfaction, ease of use, and effectiveness, physicians gave higher ratings to genetic test reports developed with the template than standard reports used by clinical laboratories. Physicians least familiar with genetic test reports, and possibly having the greatest need for better communication, were best served by the template reports.

  10. A radiographic template for a two-implant mandibular overdenture using the patient’s existing denture

    PubMed Central

    Huynh-Ba, G; Alexander, P; Vargas, A; Vierra, M; Oates, TW

    2012-01-01

    This article introduces a technique for modifying an existing mandibular complete denture for use as a radiographic template with a radiopaque light-activated calcium hydroxide (Ca(OH)2) preparation. This allows prosthetically-driven treatment planning and surgical placement of 2 implants to support the existing mandibular denture. PMID:23328197

  11. 48 CFR 307.104 - General procedures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... regarding the specific acquisition method the contracting activity plans to use. (5) HHS requires use of a standard format for an AAP. The template for the plan is available on the ASFR/OGAPA/DA Internet Web site...

  12. Adaptation of the CVT algorithm for catheter optimization in high dose rate brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poulin, Eric; Fekete, Charles-Antoine Collins; Beaulieu, Luc

    2013-11-15

    Purpose: An innovative, simple, and fast method to optimize the number and position of catheters is presented for prostate and breast high dose rate (HDR) brachytherapy, both for arbitrary templates or template-free implants (such as robotic templates).Methods: Eight clinical cases were chosen randomly from a bank of patients, previously treated in our clinic to test our method. The 2D Centroidal Voronoi Tessellations (CVT) algorithm was adapted to distribute catheters uniformly in space, within the maximum external contour of the planning target volume. The catheters optimization procedure includes the inverse planning simulated annealing algorithm (IPSA). Complete treatment plans can then bemore » generated from the algorithm for different number of catheters. The best plan is chosen from different dosimetry criteria and will automatically provide the number of catheters and their positions. After the CVT algorithm parameters were optimized for speed and dosimetric results, it was validated against prostate clinical cases, using clinically relevant dose parameters. The robustness to implantation error was also evaluated. Finally, the efficiency of the method was tested in breast interstitial HDR brachytherapy cases.Results: The effect of the number and locations of the catheters on prostate cancer patients was studied. Treatment plans with a better or equivalent dose distributions could be obtained with fewer catheters. A better or equal prostate V100 was obtained down to 12 catheters. Plans with nine or less catheters would not be clinically acceptable in terms of prostate V100 and D90. Implantation errors up to 3 mm were acceptable since no statistical difference was found when compared to 0 mm error (p > 0.05). No significant difference in dosimetric indices was observed for the different combination of parameters within the CVT algorithm. A linear relation was found between the number of random points and the optimization time of the CVT algorithm. Because the computation time decrease with the number of points and that no effects were observed on the dosimetric indices when varying the number of sampling points and the number of iterations, they were respectively fixed to 2500 and to 100. The computation time to obtain ten complete treatments plans ranging from 9 to 18 catheters, with the corresponding dosimetric indices, was 90 s. However, 93% of the computation time is used by a research version of IPSA. For the breast, on average, the Radiation Therapy Oncology Group recommendations would be satisfied down to 12 catheters. Plans with nine or less catheters would not be clinically acceptable in terms of V100, dose homogeneity index, and D90.Conclusions: The authors have devised a simple, fast and efficient method to optimize the number and position of catheters in interstitial HDR brachytherapy. The method was shown to be robust for both prostate and breast HDR brachytherapy. More importantly, the computation time of the algorithm is acceptable for clinical use. Ultimately, this catheter optimization algorithm could be coupled with a 3D ultrasound system to allow real-time guidance and planning in HDR brachytherapy.« less

  13. Pre-operative digital templating in cemented hip hemiarthroplasty for neck of femur fractures.

    PubMed

    Kwok, Iris H Y; Pallett, Scott J C; Massa, Edward; Cundall-Curry, Duncan; Loeffler, Mark D

    2016-03-01

    Pre-operative digital templating allows the surgeon to foresee any anatomical anomalies which may lead to intra-operative problems, and anticipate appropriate instruments and implants required during surgery. Although its role is well-established in successful elective total hip arthroplasty, little work has been done on its use in hip hemiarthroplasty in neck of femur fractures. We describe our initial experience of digital templating in 40 consecutive patients who have undergone cemented hip hemiarthroplasty, assessing templating accuracy between templated implant sizes to actual implant sizes. 81% of implanted heads were templated to within two head sizes, and 89% of implanted stems were templated to within two sizes. Although there was a moderately strong correlation of 0.52 between templated and actual head sizes, this correlation was not demonstrated in femoral stem sizes. Mean leg length discrepancy was -2.5mm (S.D. 8.5), and the mean difference in femoral offset between the operated and non-operated hip was -1mm (S.D. 4.4). Digital templating is a useful adjunct to the surgeon in pre-operative planning of hip hemiarthroplasty in the restoration of leg length and femoral offset. However, its accuracy is inferior to that of elective total hip arthroplasty. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Whole-body hybrid imaging concept for the integration of PET/MR into radiation therapy treatment planning.

    PubMed

    Paulus, Daniel H; Oehmigen, Mark; Grüneisen, Johannes; Umutlu, Lale; Quick, Harald H

    2016-05-07

    Modern radiation therapy (RT) treatment planning is based on multimodality imaging. With the recent availability of whole-body PET/MR hybrid imaging new opportunities arise to improve target volume delineation in RT treatment planning. This, however, requires dedicated RT equipment for reproducible patient positioning on the PET/MR system, which has to be compatible with MR and PET imaging. A prototype flat RT table overlay, radiofrequency (RF) coil holders for head imaging, and RF body bridges for body imaging were developed and tested towards PET/MR system integration. Attenuation correction (AC) of all individual RT components was performed by generating 3D CT-based template models. A custom-built program for μ-map generation assembles all AC templates depending on the presence and position of each RT component. All RT devices were evaluated in phantom experiments with regards to MR and PET imaging compatibility, attenuation correction, PET quantification, and position accuracy. The entire RT setup was then evaluated in a first PET/MR patient study on five patients at different body regions. All tested devices are PET/MR compatible and do not produce visible artifacts or disturb image quality. The RT components showed a repositioning accuracy of better than 2 mm. Photon attenuation of  -11.8% in the top part of the phantom was observable, which was reduced to  -1.7% with AC using the μ-map generator. Active lesions of 3 subjects were evaluated in terms of SUVmean and an underestimation of  -10.0% and  -2.4% was calculated without and with AC of the RF body bridges, respectively. The new dedicated RT equipment for hybrid PET/MR imaging enables acquisitions in all body regions. It is compatible with PET/MR imaging and all hardware components can be corrected in hardware AC by using the suggested μ-map generator. These developments provide the technical and methodological basis for integration of PET/MR hybrid imaging into RT planning.

  15. Template optimization and transfer in perceptual learning.

    PubMed

    Kurki, Ilmari; Hyvärinen, Aapo; Saarinen, Jussi

    2016-08-01

    We studied how learning changes the processing of a low-level Gabor stimulus, using a classification-image method (psychophysical reverse correlation) and a task where observers discriminated between slight differences in the phase (relative alignment) of a target Gabor in visual noise. The method estimates the internal "template" that describes how the visual system weights the input information for decisions. One popular idea has been that learning makes the template more like an ideal Bayesian weighting; however, the evidence has been indirect. We used a new regression technique to directly estimate the template weight change and to test whether the direction of reweighting is significantly different from an optimal learning strategy. The subjects trained the task for six daily sessions, and we tested the transfer of training to a target in an orthogonal orientation. Strong learning and partial transfer were observed. We tested whether task precision (difficulty) had an effect on template change and transfer: Observers trained in either a high-precision (small, 60° phase difference) or a low-precision task (180°). Task precision did not have an effect on the amount of template change or transfer, suggesting that task precision per se does not determine whether learning generalizes. Classification images show that training made observers use more task-relevant features and unlearn some irrelevant features. The transfer templates resembled partially optimized versions of templates in training sessions. The template change direction resembles ideal learning significantly but not completely. The amount of template change was highly correlated with the amount of learning.

  16. Accurate and Simple Screw Insertion Procedure With Patient-Specific Screw Guide Templates for Posterior C1-C2 Fixation.

    PubMed

    Sugawara, Taku; Higashiyama, Naoki; Kaneyama, Shuichi; Sumi, Masatoshi

    2017-03-15

    Prospective clinical trial of the screw insertion method for posterior C1-C2 fixation utilizing the patient-specific screw guide template technique. To evaluate the efficacy of this method for insertion of C1 lateral mass screws (LMS), C2 pedicle screws (PS), and C2 laminar screws (LS). Posterior C1LMS and C2PS fixation, also known as the Goel-Harms method, can achieve immediate rigid fixation and high fusion rate, but the screw insertion carries the risk of injury to neuronal and vascular structures. Dissection of venous plexus and C2 nerve root to confirm the insertion point of the C1LMS may also cause problems. We have developed an intraoperative screw guiding method using patient-specific laminar templates. Preoperative bone images of computed tomography (CT) were analyzed using three-dimensional (3D)/multiplanar imaging software to plan the trajectories of the screws. Plastic templates with screw guiding structures were created for each lamina using 3D design and printing technology. Three types of templates were made for precise multistep guidance, and all templates were specially designed to fit and lock on the lamina during the procedure. Surgery was performed using this patient-specific screw guide template system, and placement of the screws was postoperatively evaluated using CT. Twelve patients with C1-C2 instability were treated with a total of 48 screws (24 C1LMS, 20 C2PS, 4 C2LS). Intraoperatively, each template was found to exactly fit and lock on the lamina and screw insertion was completed successfully without dissection of the venous plexus and C2 nerve root. Postoperative CT showed no cortical violation by the screws, and mean deviation of the screws from the planned trajectories was 0.70 ± 0.42 mm. The multistep, patient-specific screw guide template system is useful for intraoperative screw navigation in posterior C1-C2 fixation. This simple and economical method can improve the accuracy of screw insertion, and reduce operation time and radiation exposure of posterior C1-C2 fixation surgery. 3.

  17. Template for Conceptual Model Construction: Model Components and Application of the Template

    DTIC Science & Technology

    2007-09-01

    stressors, focused through EECs, result in endpoints (Lubinski and Barko 2003). Endpoints are quantifiable, ecologically significant, and important to...Monitoring Plan (Thomas et al. 2001) Lake Okeechobee (Havens 1999) EPA Ecological Risk Assessment on Terrestrial Ecosystem (Suter 1996) Grassland...endpoints (Havens 1999) are examples of Hydrologic Resources: Water Quality, and Terrestrial Resources: Biota. The EPA Ecological Risk Assessment (Suter

  18. Digital approach to planning computer-guided surgery and immediate provisionalization in a partially edentulous patient.

    PubMed

    Arunyanak, Sirikarn P; Harris, Bryan T; Grant, Gerald T; Morton, Dean; Lin, Wei-Shao

    2016-07-01

    This report describes a digital approach for computer-guided surgery and immediate provisionalization in a partially edentulous patient. With diagnostic data obtained from cone-beam computed tomography and intraoral digital diagnostic scans, a digital pathway of virtual diagnostic waxing, a virtual prosthetically driven surgical plan, a computer-aided design and computer-aided manufacturing (CAD/CAM) surgical template, and implant-supported screw-retained interim restorations were realized with various open-architecture CAD/CAM systems. The optional CAD/CAM diagnostic casts with planned implant placement were also additively manufactured to facilitate preoperative inspection of the surgical template and customization of the CAD/CAM-fabricated interim restorations. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  19. Journal of Chemical Education: Software.

    ERIC Educational Resources Information Center

    Journal of Chemical Education, 1989

    1989-01-01

    "Spreadsheets in Physical Chemistry" contains reviewed and classroom tested Lotus 1-2-3 and SuperCalc IV templates and handouts designed for use in physical chemistry courses. The 21 templates keyed to Atkins' physical chemistry textbook, the 7 numerical methods templates, and the 10 simulation templates are discussed. (MVL)

  20. Using Patient Demographics and Statistical Modeling to Predict Knee Tibia Component Sizing in Total Knee Arthroplasty.

    PubMed

    Ren, Anna N; Neher, Robert E; Bell, Tyler; Grimm, James

    2018-06-01

    Preoperative planning is important to achieve successful implantation in primary total knee arthroplasty (TKA). However, traditional TKA templating techniques are not accurate enough to predict the component size to a very close range. With the goal of developing a general predictive statistical model using patient demographic information, ordinal logistic regression was applied to build a proportional odds model to predict the tibia component size. The study retrospectively collected the data of 1992 primary Persona Knee System TKA procedures. Of them, 199 procedures were randomly selected as testing data and the rest of the data were randomly partitioned between model training data and model evaluation data with a ratio of 7:3. Different models were trained and evaluated on the training and validation data sets after data exploration. The final model had patient gender, age, weight, and height as independent variables and predicted the tibia size within 1 size difference 96% of the time on the validation data, 94% of the time on the testing data, and 92% on a prospective cadaver data set. The study results indicated the statistical model built by ordinal logistic regression can increase the accuracy of tibia sizing information for Persona Knee preoperative templating. This research shows statistical modeling may be used with radiographs to dramatically enhance the templating accuracy, efficiency, and quality. In general, this methodology can be applied to other TKA products when the data are applicable. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. [Preliminary safety and stability assessment of orthodontic miniscrew implantation guided by surgical template based on cone-beam CT images].

    PubMed

    Qiu, L L; Li, S; Bai, Y X

    2016-06-01

    To develop surgical templates for orthodontic miniscrew implantation based on cone-beam CT(CBCT)three-dimensional(3D)images and to evaluate the safety and stability of implantation guided by the templates. DICOM data obtained in patients who had CBCT scans taken were processed using Mimics software, and 3D images of teeth and maxillary bone were acquired. Meanwhile, 3D images of miniscrews were acquired using Solidworks software and processed with Mimics software. Virtual position of miniscrews was determined based on 3D images of teeth, bone, and miniscrews. 3D virtual templates were designed according to the virtual implantation plans. STL files were output and the real templates were fabricated with stereolithographic appliance(SLA). Postoperative CBCT scans were used to evaluate the implantation safety and the stability of miniscrews were investigated. All the templates were positioned accurately and kept stable throughout the implantation process. No root damage was found. The deviations were(1.73±0.65)mm at the corona, and(1.28±0.82)mm at the apex, respectively. The stability of miniscrews was fairly well. Surgical templates for miniscrew implantation could be acquired based on 3D CBCT images and fabricated with SLA. Implantation guided by these templates was safe and stable.

  2. Computer-assisted template-guided custom-designed 3D-printed implant placement with custom-designed 3D-printed surgical tooling: an in-vitro proof of a novel concept.

    PubMed

    Anssari Moin, David; Derksen, Wiebe; Waars, Hugo; Hassan, Bassam; Wismeijer, Daniel

    2017-05-01

    The aim of this study was to introduce a new concept for computer-assisted template-guided placement of a custom 3D-designed/3D-printed implant with congruent custom 3D-designed/3D-printed surgical tooling and to test the feasibility and accuracy of this method in-vitro. One partially edentulous human mandibular cadaver was scanned with a cone-beam computed tomography (CBCT) system and intra-oral scan system. The 3D data of this cadaver were imported in specialized software and used to analyse the region of a missing tooth. Based on the functional and anatomical parameters, an individual implant with congruent surgical tooling and surgical guided template was designed and 3D-printed. The guided osteotomy was performed, and the custom implant inserted. To evaluate the planned implant position in comparison with the placed implant position, the mandible with implant was scanned again with the CBCT system and software matching was applied to measure the accuracy of the procedure. The angular deflection with the planned implant position was 0.40°. When comparing the 3D positions of the shoulder, there is a deviation of 0.72 mm resulting in an apical deviation of 0.72 mm. With the use of currently available technology, it is very well feasible to create in a virtual simulation a custom implant with congruent custom surgical tooling and to transfer this to a clinical setting. However, further research on multiple levels is needed to explore this novel approach. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Standardized Protocol for Virtual Surgical Plan and 3-Dimensional Surgical Template-Assisted Single-Stage Mandible Contour Surgery.

    PubMed

    Fu, Xi; Qiao, Jia; Girod, Sabine; Niu, Feng; Liu, Jian Feng; Lee, Gordon K; Gui, Lai

    2017-09-01

    Mandible contour surgery, including reduction gonioplasty and genioplasty, has become increasingly popular in East Asia. However, it is technically challenging and, hence, leads to a long learning curve and high complication rates and often needs secondary revisions. The increasing use of 3-dimensional (3D) technology makes accurate single-stage mandible contour surgery with minimum complication rates possible with a virtual surgical plan (VSP) and 3-D surgical templates. This study is to establish a standardized protocol for VSP and 3-D surgical templates-assisted mandible contour surgery and evaluate the accuracy of the protocol. In this study, we enrolled 20 patients for mandible contour surgery. Our protocol is to perform VSP based on 3-D computed tomography data. Then, design and 3-D print surgical templates based on preoperative VSP. The accuracy of the method was analyzed by 3-D comparison of VSP and postoperative results using detailed computer analysis. All patients had symmetric, natural osteotomy lines and satisfactory facial ratios in a single-stage operation. The average relative error of VSP and postoperative result on the entire skull was 0.41 ± 0.13 mm. The average new left gonial error was 0.43 ± 0.77 mm. The average new right gonial error was 0.45 ± 0.69 mm. The average pognion error was 0.79 ± 1.21 mm. Patients were very satisfied with the aesthetic results. Surgeons were very satisfied with the performance of surgical templates to facilitate the operation. Our standardized protocol of VSP and 3-D printed surgical templates-assisted single-stage mandible contour surgery results in accurate, safe, and predictable outcome in a single stage.

  4. SU-E-T-109: Development of An End-To-End Test for the Varian TrueBeamtm with a Novel Multiple-Dosimetric Modality H and N Phantom

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zakjevskii, V; Knill, C; Rakowski, J

    2014-06-01

    Purpose: To develop a comprehensive end-to-end test for Varian's TrueBeam linear accelerator for head and neck IMRT using a custom phantom designed to utilize multiple dosimetry devices. Methods: The initial end-to-end test and custom H and N phantom were designed to yield maximum information in anatomical regions significant to H and N plans with respect to: i) geometric accuracy, ii) dosimetric accuracy, and iii) treatment reproducibility. The phantom was designed in collaboration with Integrated Medical Technologies. A CT image was taken with a 1mm slice thickness. The CT was imported into Varian's Eclipse treatment planning system, where OARs and themore » PTV were contoured. A clinical template was used to create an eight field static gantry angle IMRT plan. After optimization, dose was calculated using the Analytic Anisotropic Algorithm with inhomogeneity correction. Plans were delivered with a TrueBeam equipped with a high definition MLC. Preliminary end-to-end results were measured using film and ion chambers. Ion chamber dose measurements were compared to the TPS. Films were analyzed with FilmQAPro using composite gamma index. Results: Film analysis for the initial end-to-end plan with a geometrically simple PTV showed average gamma pass rates >99% with a passing criterion of 3% / 3mm. Film analysis of a plan with a more realistic, ie. complex, PTV yielded pass rates >99% in clinically important regions containing the PTV, spinal cord and parotid glands. Ion chamber measurements were on average within 1.21% of calculated dose for both plans. Conclusion: trials have demonstrated that our end-to-end testing methods provide baseline values for the dosimetric and geometric accuracy of Varian's TrueBeam system.« less

  5. Magnification of digital hip radiographs differs between clinical workplaces.

    PubMed

    Hornová, Jana; Růžička, Pavel; Hrubina, Maroš; Šťastný, Eduard; Košková, Andrea; Fulín, Petr; Gallo, Jiří; Daniel, Matej

    2017-01-01

    Preoperative planning for total hip arthroplasty includes templating on anteroposterior radiographs. It is necessary to consider radiographic magnification in order to scale templates accurately. Studies dealing with hip templating report different values of radiographic magnification. It is not clear if the observed difference in magnification between the studies is caused by variability in studied groups, methodology or instrumentation. We hypothesize that there is a difference in magnification between clinical workplaces. Within this study, radiographic magnification was estimated on 337 radiographs of patients after total hip surgery from five orthopaedic departments in the Czech Republic. Magnification was determined for each patient as a ratio between diameter of implanted femoral head measured on radiogram and its true size. One-way ANOVA revealed significant differences in magnification between workplaces (F(4,332) = 132, p≤0.001). These results suggest that radiographic magnification depends on the workplace where it is taken or more precisely on radiographic device. It indicates potential limits in generalizability of results of studies dealing with preoperative planning accuracy to other institutions.

  6. Ten Steps to Create Virtual Smile Design Templates With Adobe Photoshop® CS6.

    PubMed

    Sundar, Manoj Kumar; Chelliah, Venkataraman

    2018-03-01

    Computer design software has become a primary tool for communication among the dentist, patient, and ceramist. Virtual smile design can be carried out using various software programs, most of which use assorted forms of teeth templates that are made based on the concept of "golden proportion." Despite current advances in 3-dimensional imaging and smile designing, many clinicians still employ conventional design methods and analog (ie, man-made) mock-ups in assessing and establishing esthetic makeovers. To simplify virtual smile designing, the teeth templates should be readily available. No literature has provided details as to how to create these templates. This article explains a technique for creating different forms of teeth templates using Adobe Photoshop® CS6 that eventually can be used for smile design purposes, either in Photoshop or Microsoft Powerpoint. Clinically speaking, various smile design templates created using set proportions in Adobe Photoshop CS6 can be used in virtual smile designing, a valuable resource in diagnosis, treatment planning, and communicating with patients and ceramists, thus providing a platform for a successful esthetic rehabilitation.

  7. PREP: Portal for Readiness Exercises & Planning v. 1.0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Noel, Todd; Le, Tam; McNeil, Carrie

    2016-10-28

    The software includes a web-based template for recording actions taken during emergency preparedness exercises and planning workshops. In addition, a virtual outbreak prevention simulation exercise is also included. Both tools interact with a server which records user decisions and communications.

  8. The Radiologist Is in, but Was it Worth the Wait? Radiology Resident Note Quality in an Outpatient Interventional Radiology Clinic.

    PubMed

    Abboud, Salim E; Soriano, Stephanie; Abboud, Rayan; Patel, Indravadan; Davidson, Jon; Azar, Nami R; Nakamoto, Dean A

    Preprocedural evaluation of patients in an interventional radiology (IR) clinic is a complex synthesis of physical examination and imaging findings, and as IR transitions to an independent clinical specialty, such evaluations will become an increasingly critical component of a successful IR practice and quality patient care. Prior research suggests that preprocedural evaluations increased patient's perceived quality of care and may improve procedural technical success rates. Appropriate documentation of a preprocedural evaluation in the medical record is also paramount for an interventional radiologist to add value and function as an effective member of a larger IR service and multidisciplinary health care team. The purpose of this study is to examine the quality of radiology resident notes for patients seen in an outpatient IR clinic at a single academic medical center before and after the adoption of clinic note template with reminders to include platelet count, international normalized ratio, glomerular filtration rate, and plan for periprocedural coagulation status. Before adoption of the template, platelet count, international normalized ratio, glomerular filtration rate and an appropriate plan for periprocedural coagulation status were documented in 72%, 82%, 42%, and 33% of patients, respectively. After adoption of the template, appropriate documentation of platelet count, international normalized ratio, and glomerular filtration rate increased to 96%, and appropriate plan for periprocedural coagulation status was documented in 83% of patients. Patient evaluation and clinical documentation skills may not be adequately practiced during radiology residency, and tools such as templates may help increase documentation quality by radiology residents. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Framework for adaptive multiscale analysis of nonhomogeneous point processes.

    PubMed

    Helgason, Hannes; Bartroff, Jay; Abry, Patrice

    2011-01-01

    We develop the methodology for hypothesis testing and model selection in nonhomogeneous Poisson processes, with an eye toward the application of modeling and variability detection in heart beat data. Modeling the process' non-constant rate function using templates of simple basis functions, we develop the generalized likelihood ratio statistic for a given template and a multiple testing scheme to model-select from a family of templates. A dynamic programming algorithm inspired by network flows is used to compute the maximum likelihood template in a multiscale manner. In a numerical example, the proposed procedure is nearly as powerful as the super-optimal procedures that know the true template size and true partition, respectively. Extensions to general history-dependent point processes is discussed.

  10. A pilot study of a heuristic algorithm for novel template identification from VA electronic medical record text.

    PubMed

    Redd, Andrew M; Gundlapalli, Adi V; Divita, Guy; Carter, Marjorie E; Tran, Le-Thuy; Samore, Matthew H

    2017-07-01

    Templates in text notes pose challenges for automated information extraction algorithms. We propose a method that identifies novel templates in plain text medical notes. The identification can then be used to either include or exclude templates when processing notes for information extraction. The two-module method is based on the framework of information foraging and addresses the hypothesis that documents containing templates and the templates within those documents can be identified by common features. The first module takes documents from the corpus and groups those with common templates. This is accomplished through a binned word count hierarchical clustering algorithm. The second module extracts the templates. It uses the groupings and performs a longest common subsequence (LCS) algorithm to obtain the constituent parts of the templates. The method was developed and tested on a random document corpus of 750 notes derived from a large database of US Department of Veterans Affairs (VA) electronic medical notes. The grouping module, using hierarchical clustering, identified 23 groups with 3 documents or more, consisting of 120 documents from the 750 documents in our test corpus. Of these, 18 groups had at least one common template that was present in all documents in the group for a positive predictive value of 78%. The LCS extraction module performed with 100% positive predictive value, 94% sensitivity, and 83% negative predictive value. The human review determined that in 4 groups the template covered the entire document, with the remaining 14 groups containing a common section template. Among documents with templates, the number of templates per document ranged from 1 to 14. The mean and median number of templates per group was 5.9 and 5, respectively. The grouping method was successful in finding like documents containing templates. Of the groups of documents containing templates, the LCS module was successful in deciphering text belonging to the template and text that was extraneous. Major obstacles to improved performance included documents composed of multiple templates, templates that included other templates embedded within them, and variants of templates. We demonstrate proof of concept of the grouping and extraction method of identifying templates in electronic medical records in this pilot study and propose methods to improve performance and scaling up. Published by Elsevier Inc.

  11. A Template Analysis of Intimate Partner Violence Survivors' Experiences of Animal Maltreatment: Implications for Safety Planning and Intervention.

    PubMed

    Collins, Elizabeth A; Cody, Anna M; McDonald, Shelby Elaine; Nicotera, Nicole; Ascione, Frank R; Williams, James Herbert

    2018-03-01

    This study explores the intersection of intimate partner violence (IPV) and animal cruelty in an ethnically diverse sample of 103 pet-owning IPV survivors recruited from community-based domestic violence programs. Template analysis revealed five themes: (a) Animal Maltreatment by Partner as a Tactic of Coercive Power and Control, (b) Animal Maltreatment by Partner as Discipline or Punishment of Pet, (c) Animal Maltreatment by Children, (d) Emotional and Psychological Impact of Animal Maltreatment Exposure, and (e) Pets as an Obstacle to Effective Safety Planning. Results demonstrate the potential impact of animal maltreatment exposure on women and child IPV survivors' health and safety.

  12. A Template Analysis of Intimate Partner Violence Survivors’ Experiences of Animal Maltreatment: Implications for Safety Planning and Intervention

    PubMed Central

    Collins, Elizabeth A.; Cody, Anna M.; McDonald, Shelby Elaine; Nicotera, Nicole; Ascione, Frank R.; Williams, James Herbert

    2018-01-01

    This study explores the intersection of intimate partner violence (IPV) and animal cruelty in an ethnically diverse sample of 103 pet-owning IPV survivors recruited from community-based domestic violence programs. Template analysis revealed five themes: (a) Animal Maltreatment by Partner as a Tactic of Coercive Power and Control, (b) Animal Maltreatment by Partner as Discipline or Punishment of Pet, (c) Animal Maltreatment by Children, (d) Emotional and Psychological Impact of Animal Maltreatment Exposure, and (e) Pets as an Obstacle to Effective Safety Planning. Results demonstrate the potential impact of animal maltreatment exposure on women and child IPV survivors’ health and safety. PMID:29332521

  13. Visual environment recognition for robot path planning using template matched filters

    NASA Astrophysics Data System (ADS)

    Orozco-Rosas, Ulises; Picos, Kenia; Díaz-Ramírez, Víctor H.; Montiel, Oscar; Sepúlveda, Roberto

    2017-08-01

    A visual approach in environment recognition for robot navigation is proposed. This work includes a template matching filtering technique to detect obstacles and feasible paths using a single camera to sense a cluttered environment. In this problem statement, a robot can move from the start to the goal by choosing a single path between multiple possible ways. In order to generate an efficient and safe path for mobile robot navigation, the proposal employs a pseudo-bacterial potential field algorithm to derive optimal potential field functions using evolutionary computation. Simulation results are evaluated in synthetic and real scenes in terms of accuracy of environment recognition and efficiency of path planning computation.

  14. Mandibular reconstruction with the vascularized fibula flap: comparison of virtual planning surgery and conventional surgery.

    PubMed

    Wang, Y Y; Zhang, H Q; Fan, S; Zhang, D M; Huang, Z Q; Chen, W L; Ye, J T; Li, J S

    2016-11-01

    This study evaluated the accuracy of mandibular reconstruction and assessed clinical outcomes in both virtual planning and conventional surgery patients. ProPlan CMF surgical planning software was used preoperatively in the virtual planning group. In the virtual planning group, fibula flaps were harvested and osteotomized, and the mandibles were resected and reconstructed assisted by the prefabricated cutting guides and templates. The main outcome measures included the operative time, postoperative computed tomography (CT) scans, facial appearance, and occlusal function. The ischemia time and total operation time were shorter in the virtual planning group than in the conventional surgery group. High precision with the use of the cutting guides and templates was found for both the fibula and mandible, and a good fit was noted among the pre-bent plate, mandible, and fibula segments in the virtual planning group. Postoperative CT scans also showed excellent mandibular contours of the fibula flaps in accordance with virtual plans in the virtual planning group. This study demonstrated that virtual surgical planning was able to achieve more accurate mandibular reconstruction than conventional surgery. The use of prefabricated cutting guides and plates makes fibula flap moulding and placement easier, minimizes the operating time, and improves clinical outcomes. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  15. A fast inverse treatment planning strategy facilitating optimized catheter selection in image-guided high-dose-rate interstitial gynecologic brachytherapy.

    PubMed

    Guthier, Christian V; Damato, Antonio L; Hesser, Juergen W; Viswanathan, Akila N; Cormack, Robert A

    2017-12-01

    Interstitial high-dose rate (HDR) brachytherapy is an important therapeutic strategy for the treatment of locally advanced gynecologic (GYN) cancers. The outcome of this therapy is determined by the quality of dose distribution achieved. This paper focuses on a novel yet simple heuristic for catheter selection for GYN HDR brachytherapy and their comparison against state of the art optimization strategies. The proposed technique is intended to act as a decision-supporting tool to select a favorable needle configuration. The presented heuristic for catheter optimization is based on a shrinkage-type algorithm (SACO). It is compared against state of the art planning in a retrospective study of 20 patients who previously received image-guided interstitial HDR brachytherapy using a Syed Neblett template. From those plans, template orientation and position are estimated via a rigid registration of the template with the actual catheter trajectories. All potential straight trajectories intersecting the contoured clinical target volume (CTV) are considered for catheter optimization. Retrospectively generated plans and clinical plans are compared with respect to dosimetric performance and optimization time. All plans were generated with one single run of the optimizer lasting 0.6-97.4 s. Compared to manual optimization, SACO yields a statistically significant (P ≤ 0.05) improved target coverage while at the same time fulfilling all dosimetric constraints for organs at risk (OARs). Comparing inverse planning strategies, dosimetric evaluation for SACO and "hybrid inverse planning and optimization" (HIPO), as gold standard, shows no statistically significant difference (P > 0.05). However, SACO provides the potential to reduce the number of used catheters without compromising plan quality. The proposed heuristic for needle selection provides fast catheter selection with optimization times suited for intraoperative treatment planning. Compared to manual optimization, the proposed methodology results in fewer catheters without a clinically significant loss in plan quality. The proposed approach can be used as a decision support tool that guides the user to find the ideal number and configuration of catheters. © 2017 American Association of Physicists in Medicine.

  16. Unusual anchor pins placement and protocol deviations during computer-based implant placement in a patient with severe mandibular bone atrophy. A case report.

    PubMed

    Pozzi, A; Tallarico, M; Barlattani, A

    2012-06-01

    The aim of the study was to describe an unusual method to stabilize the surgical template during the treatment of a severely resorbed edentulous mandible by means of computer-guided implant surgery. Pre-operative computer-based planning revealed the difficulty to stabilize the surgical template in a 67-year-old healthy woman. A deviation of the original NobelGuide™ protocol was performed to ensure the stability of the surgical template: four anchor pins were used to stabilize the surgical template, two in the buccal side of the anterior template and two unusual pins were placed in the lingual site. Four straight TiUnite® Nobel Biocare™ implants were then placed, according to a modified All-on-4™ concept procedure, to avoid graft procedures and to reduce the cumulative chair-side treatment time and costs. A temporary restoration was placed immediately after implant placement. Three months later a definitive, full acrylic restoration was delivered.

  17. 78 FR 15403 - Agency Information Collection Activities; Proposed Collection; Comment Request; Company-Run...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-11

    ... Activities; Proposed Collection; Comment Request; Company-Run Annual Stress Test Reporting Template and... Federal savings associations titled, ``Company-Run Annual Stress Test Reporting Template and Documentation....occ.gov/tools-forms/forms/bank-operations/stress-test-reporting.html ). SUPPLEMENTARY INFORMATION: The...

  18. Battery Data MI Importer Template Quick Start Guide

    NASA Technical Reports Server (NTRS)

    Levinson, Laurie H.

    2017-01-01

    In order to ensure the persistent availability and reliability of test data generated over the course of the project, the M-SHELLS Project has decided to store acquired test data, as well as associated pedigree information, in the Granta Materials Intelligence (MI) database. To facilitate that effort, an importer template and associated graphical user interface (GUI) software have been developed, with this guide providing the operating instructions for their use. The template and automation software GUI are contained in the BatteryDataImporter.xlsm Excel workbook, and are to be used to import M-SHELLS summary, or pedigree, data and the associated raw test data results into an importer template-based file, formatted in such a way as to be ready for immediate upload to the Test Data: Battery Performance table of the Granta MI database. The provided GUI enables the user to select the appropriate summary data file(s), with each file containing the required information to identify any associated raw test data file(s) to be processed. In addition to describing the setup and operation of the importer template and GUI software, this guide also provides instructions for uploading processed data to the database and for viewing the data following upload.

  19. Development of a methodology for structured reporting of information in echocardiography.

    PubMed

    Homorodean, Călin; Olinic, Maria; Olinic, Dan

    2012-03-01

    In order to conduct research relying on ultrasound images, it is necessary to access a large number of relevant cases represented by images and their interpretation. DICOM standard defines the structured reporting information object. Templates are tree-like structures which offer structural guidance in report construction. Laying the foundations of a structured reporting methodology in echocardiography, through the generation of a consistent set of DICOM templates. We developed an information system with the ability of managing echocardiographic images and structured reports. In order to perform a complete description of the cardiac structures, we used 1900 coded concepts organized into 344 contexts by their semantic meaning in a variety of cardiac diseases. We developed 30 templates, with up to 10 nesting levels. The list of templates has a pyramid-like architecture. Two templates are used for reporting every measurement and description: "EchoMeasurement" and "EchoDescription". Intermediate level templates specify how to report the features of echoDoppler findings: "Spectral Curve", "Color Jet", "Intracardiac mass". Templates for every cardiovascular structure include the previous ones. "Echocardiography Procedure Report" includes all other templates. The templates were tested in reporting echo features of 100 patients by analyzing 500 DICOM images. The benefits of these templates has been proven during the testing process, through the quality of the echocardiography report, the ability to argue and to link every diagnostic feature to a defining image and by opening up opportunities for education, research. In the future, our template-based reporting methodology might be extended to other imaging modalities.

  20. Evaluation of State Plans and the Livestock Emergency Response Plan (LERP).

    PubMed

    Schaffer, Amy M; Burton, Kenneth R

    The Livestock Emergency Response Plan (LERP) was published in 2014 as a toolkit to assist state agricultural emergency planners in writing or modifying state foreign animal disease/high-consequence disease (FAD/HCD) plans. This research serves as a follow-up to and expands on an initial survey conducted in 2011 by the Department of Homeland Security Office of Health Affairs, Food, Ag, and Veterinary Defense Branch. The purpose of this project is to describe the status of current state animal disease response plans in relation to how closely their content, order, and terminology relate to that described in the LERP template. The analysis was compared to the 2011 study to identify advances, trends, continued areas for increased alignment, and fulfillment of planning gaps in individual state plans. While vast improvements were made in the status of state animal disease response plans from 2011 to 2016, there is nonetheless significant room for enhancing consistency between and identifying gaps in FAD/HCD plans. As awareness of the LERP toolkit grows, the authors hope its use as a template by the states will expand accordingly, thereby increasing consistency between plans and more thoroughly addressing challenges in an FAD/HCD outbreak. The results of this study support the need for curriculum planning resources at the state level. Development of a training curriculum and planning workshops for state agriculture emergency planners will produce a consistent planning philosophy and skill set among state planners-another means of indirectly addressing current planning gaps in agricultural emergency response.

  1. Reducing Individual Variation for fMRI Studies in Children by Minimizing Template Related Errors

    PubMed Central

    Weng, Jian; Dong, Shanshan; He, Hongjian; Chen, Feiyan; Peng, Xiaogang

    2015-01-01

    Spatial normalization is an essential process for group comparisons in functional MRI studies. In practice, there is a risk of normalization errors particularly in studies involving children, seniors or diseased populations and in regions with high individual variation. One way to minimize normalization errors is to create a study-specific template based on a large sample size. However, studies with a large sample size are not always feasible, particularly for children studies. The performance of templates with a small sample size has not been evaluated in fMRI studies in children. In the current study, this issue was encountered in a working memory task with 29 children in two groups. We compared the performance of different templates: a study-specific template created by the experimental population, a Chinese children template and the widely used adult MNI template. We observed distinct differences in the right orbitofrontal region among the three templates in between-group comparisons. The study-specific template and the Chinese children template were more sensitive for the detection of between-group differences in the orbitofrontal cortex than the MNI template. Proper templates could effectively reduce individual variation. Further analysis revealed a correlation between the BOLD contrast size and the norm index of the affine transformation matrix, i.e., the SFN, which characterizes the difference between a template and a native image and differs significantly across subjects. Thereby, we proposed and tested another method to reduce individual variation that included the SFN as a covariate in group-wise statistics. This correction exhibits outstanding performance in enhancing detection power in group-level tests. A training effect of abacus-based mental calculation was also demonstrated, with significantly elevated activation in the right orbitofrontal region that correlated with behavioral response time across subjects in the trained group. PMID:26207985

  2. Template synthesis of test tube nanoparticles using non-destructive replication

    PubMed Central

    Wagner, Jonathan; Yao, Jingyuan; Rodgers, David; Hinds, Bruce

    2013-01-01

    Nano test tubes are a promising delivery vehicle for a range of therapeutics including small molecule drugs and biologics. However, current template synthesis methods of producing nano test tubes are prohibitively expensive and time consuming. Here, non-destructive template replication was used to increase nano test tube yield from porous alumina by more than a hundredfold. We demonstrate how to produce nano test tubes of several sizes and compositions including hybrid tubes with different inner and outer surfaces for targeted surface chemistry. Nano test tubes were readily suspended and stored in aqueous solutions without the need for chemical treatment. These nano test tubes should find application as delivery vehicles for therapeutics, particularly for processive “bionanoreactors” loaded with enzymes. PMID:23376956

  3. 77 FR 66663 - Agency Information Collection Activities: Proposed Information Collection; Submission for OMB Review

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-06

    ... titled, ``Company-Run Annual Stress Test Reporting Template and Documentation for Covered Institutions... review and clearance. Company-Run Annual Stress Test Reporting Template and Documentation for Covered... savings associations, to conduct annual stress tests \\2\\ and requires the primary financial regulatory...

  4. Learned suppression for multiple distractors in visual search.

    PubMed

    Won, Bo-Yeong; Geng, Joy J

    2018-05-07

    Visual search for a target object occurs rapidly if there were no distractors to compete for attention, but this rarely happens in real-world environments. Distractors are almost always present and must be suppressed for target selection to succeed. Previous research suggests that one way this occurs is through the creation of a stimulus-specific distractor template. However, it remains unknown how information within such templates scale up with multiple distractors. Here we investigated the informational content of distractor templates created from repeated exposures to multiple distractors. We investigated this question using a visual search task in which participants searched for a gray square among colored squares. During "training," participants always saw the same set of colored distractors. During "testing," new distractor sets were interleaved with the trained distractors. The critical manipulation in each study was the distance (in color space) of the new test distractors from the trained distractors. We hypothesized that the pattern of distractor interference during testing would reveal the tuning of the suppression template: RTs should be commensurate with the degree to which distractor colors are encoded within the suppression template. Results from four experiments converged on the notion that the distractor template includes information about specific color values, but has broad "tuning," allowing suppression to generalize to new distractors. These results suggest that distractor templates, unlike target templates, encode multiple features and have broad representations, which have the advantage of generalizing suppression more easily to other potential distractors. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  5. Making the Most of What We Have Got: Enhancing the RADAR Repository to Support Research Planning

    ERIC Educational Resources Information Center

    Pike, Dawn; Siminson, Nicola Jane

    2017-01-01

    This article discusses how RADAR, the institutional repository (IR) at the Glasgow School of Art (GSA), has been modified to house an Annual Research Planning (ARP) template. A case study on the implementation of this research planning tool will outline the role that a repository and its staff can play in supporting individuals, enhancing…

  6. Task demands determine the specificity of the search template.

    PubMed

    Bravo, Mary J; Farid, Hany

    2012-01-01

    When searching for an object, an observer holds a representation of the target in mind while scanning the scene. If the observer repeats the search, performance may become more efficient as the observer hones this target representation, or "search template," to match the specific demands of the search task. An effective search template must have two characteristics: It must reliably discriminate the target from the distractors, and it must tolerate variability in the appearance of the target. The present experiment examined how the tolerance of the search template is affected by the search task. Two groups of 18 observers trained on the same set of stimuli blocked either by target image (block-by-image group) or by target category (block-by-category group). One or two days after training, both groups were tested on a related search task. The pattern of test results revealed that the two groups of observers had developed different search templates, and that the templates of the block-by-category observers better captured the general characteristics of the category. These results demonstrate that observers match their search templates to the demands of the search task.

  7. The impact of the fabrication method on the three-dimensional accuracy of an implant surgery template.

    PubMed

    Matta, Ragai-Edward; Bergauer, Bastian; Adler, Werner; Wichmann, Manfred; Nickenig, Hans-Joachim

    2017-06-01

    The use of a surgical template is a well-established method in advanced implantology. In addition to conventional fabrication, computer-aided design and computer-aided manufacturing (CAD/CAM) work-flow provides an opportunity to engineer implant drilling templates via a three-dimensional printer. In order to transfer the virtual planning to the oral situation, a highly accurate surgical guide is needed. The aim of this study was to evaluate the impact of the fabrication method on the three-dimensional accuracy. The same virtual planning based on a scanned plaster model was used to fabricate a conventional thermo-formed and a three-dimensional printed surgical guide for each of 13 patients (single tooth implants). Both templates were acquired individually on the respective plaster model using an optical industrial white-light scanner (ATOS II, GOM mbh, Braunschweig, Germany), and the virtual datasets were superimposed. Using the three-dimensional geometry of the implant sleeve, the deviation between both surgical guides was evaluated. The mean discrepancy of the angle was 3.479° (standard deviation, 1.904°) based on data from 13 patients. Concerning the three-dimensional position of the implant sleeve, the highest deviation was in the Z-axis at 0.594 mm. The mean deviation of the Euclidian distance, dxyz, was 0.864 mm. Although the two different fabrication methods delivered statistically significantly different templates, the deviations ranged within a decimillimeter span. Both methods are appropriate for clinical use. Copyright © 2017 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  8. 78 FR 62942 - Agency Information Collection Activities; Proposed Collection; Comment Request; Company-Run...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-22

    ... Activities; Proposed Collection; Comment Request; Company-Run Annual Stress Test Reporting Template and... Federal savings associations titled, ``Company-Run Annual Stress Test Reporting Template and Documentation... Web site under Tools and Forms ( http://www.occ.gov/tools-forms/forms/bank-operations/stress-test...

  9. An approach to automated particle picking from electron micrographs based on reduced representation templates.

    PubMed

    Volkmann, Niels

    2004-01-01

    Reduced representation templates are used in a real-space pattern matching framework to facilitate automatic particle picking from electron micrographs. The procedure consists of five parts. First, reduced templates are constructed either from models or directly from the data. Second, a real-space pattern matching algorithm is applied using the reduced representations as templates. Third, peaks are selected from the resulting score map using peak-shape characteristics. Fourth, the surviving peaks are tested for distance constraints. Fifth, a correlation-based outlier screening is applied. Test applications to a data set of keyhole limpet hemocyanin particles indicate that the method is robust and reliable.

  10. Water Management Plan for Fort Buchanan, Puerto Rico

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chvala, William D.; Sullivan, Gregory P.; Mcmordie, Katherine

    2004-06-01

    This document reports findings and recommendations as a result of a design assistance project with Fort Buchanan with the goals of developing a Water Management Plan (WMP). The WRMP developed during this task is an amalgam of the templates and guidelines from the Federal Energy Management Program and Army regulations.

  11. An Integrated Spreadsheet Approach to Production Planning and Control in the Introductory POM Course.

    ERIC Educational Resources Information Center

    Newman, William

    1989-01-01

    Discusses an integrated approach for presenting production planning and control fundamentals at the survey level using a Lotus 1-2-3 template. This approach provides an overview of the relationships between the problem components and highlights managerial decision-making points. (Author/JOW)

  12. Preparing Teacher Candidates for the Instruction of English Language Learners

    ERIC Educational Resources Information Center

    Gonzalez, Monica Marie

    2016-01-01

    This inquiry utilizes a sheltered instruction approach to lesson planning with the intention of improving teacher candidates' instruction to English Language Learners (ELLs). In this study a web-based questionnaire and a sheltered instruction lesson plan template were used to facilitate opportunities for teacher candidates to reflect on and…

  13. Acetate templating on digital images is more accurate than computer-based templating for total hip arthroplasty.

    PubMed

    Petretta, Robert; Strelzow, Jason; Ohly, Nicholas E; Misur, Peter; Masri, Bassam A

    2015-12-01

    Templating is an important aspect of preoperative planning for total hip arthroplasty and can help determine the size and positioning of the prosthesis. Historically, templating has been performed using acetate templates over printed radiographs. As a result of the increasing use of digital imaging, surgeons now either obtain additional printed radiographs solely for templating purposes or use specialized digital templating software, both of which carry additional cost. The purposes of this study was to compare acetate templating of digitally calibrated images on an LCD monitor to digital templating in terms of (1) accuracy; (2) reproducibility; and (3) time efficiency. Acetate onlay templating was performed directly over digital radiographs on an LCD monitor and was compared with digital templating. Five separate observers participated in this study templating on 52 total hip arthroplasties. For the acetate templating, the digital images were magnified to the scaled reference on the templates provided by the manufacturer (ratio 1.2:1) before templating using a 25-mm marker as a reference. Both the acetate and digital templating results were then compared with the actual implanted components to determine accuracy. Interobserver and intraobserver variability was determined by an intraclass correlation coefficient. Observers recorded time to complete templating from the time of complete upload of patients' imaging onto the system to completion of templating. Both acetate and digital templates demonstrated moderate accuracy in predicting within one size of the eventual implanted acetabular cup (77% [199 of 260]; 70% [181 of 260], respectively; p = 0.050; 95% confidence interval [CI], 0.058-0.32), whereas acetate templating was better at predicting the femoral stem compared to digital templating (75% [195 of 260]; 60% [155 of 260], respectively; p < 0.001; 95% CI, 0.084-0.32). Acetate templating showed moderate to substantial interobserver agreement (cup intraclass correlation coefficient [ICC] = 0.55; 95% CI, 0.14-0.86; femoral ICC = 0.75; 95% CI, 0.39-0.95) and both methods showed almost perfect intraobserver agreement in reproducibility (acetate cup ICC = 0.82; 95% CI, 0.66-0.97; acetate femoral ICC = 0.86; 95% CI, 0.74-0.97; digital cup ICC = 0.82; 95% CI, 0.68-0.97; digital femoral ICC = 0.88; 95% CI, 0.77-1.0). Acetate templating could be performed more quickly (acetate mean 119 seconds; range, 37-220 seconds versus 154 seconds; range, 73-343 seconds; p < 0.001). Acetate onlay templating on digitally calibrated images can be a reliable substitute for digital templating using specialized software. It is quicker to perform and much less expensive. Hospitals and practices need not purchase expensive software, particularly at lower volume centers. Level III, diagnostic study.

  14. 76 FR 52475 - Summary of Benefits and Coverage and Uniform Glossary-Templates, Instructions, and Related...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-22

    ...The Departments of the Health and Human Services, Labor, and the Treasury (the Departments) are simultaneously publishing in the Federal Register this document and proposed regulations (2011 proposed regulations) under the Patient Protection and Affordable Care Act to implement the disclosure for group health plans and health insurance issuers of the summary of benefits and coverage (SBC) and the uniform glossary. This document proposes a template for an SBC; instructions, sample language, and a guide for coverage examples calculations to be used in completing the template; and a uniform glossary that would satisfy the disclosure requirements under section 2715 of the Public Health Service (PHS) Act. Comments are invited on these materials.

  15. Optimization in multi-implant placement for immediate loading in edentulous arches using a modified surgical template and prototyping: a case report.

    PubMed

    Jayme, Sérgio J; Muglia, Valdir A; de Oliveira, Rafael R; Novaes, Arthur B Júnior

    2008-01-01

    Immediate loading of dental implants shortens the treatment time and makes it possible to give the patient an esthetic appearance throughout the treatment period. Placement of dental implants requires precise planning that accounts for anatomic limitations and restorative goals. Diagnosis can be made with the assistance of computerized tomographic scanning, but transfer of planning to the surgical field is limited. Recently, novel CAD/CAM techniques such as stereolithographic rapid prototyping have been developed to build surgical guides in an attempt to improve precision of implant placement. The aim of this case report was to show a modified surgical template used throughout implant placement as an alternative to a conventional surgical guide.

  16. 3D templating and patient-specific cutting guides (Knee-Plan) in total knee arthroplasty: postoperative CT-based assessment of implant positioning.

    PubMed

    Franceschi, J-P; Sbihi, A

    2014-10-01

    The precision of bone cuts and the positioning of components influence the functionality and longevity of total knee arthroplasty (TKA). The objective of this study was to evaluate the results of TKA, performed after 3D preoperative templating, with the prosthesis implanted using custom cutting guides (Knee-Plan system, Symbios Orthopédie SA). This prospective study investigated 107 TKAs. Three-dimensional preoperative templating was carried out on the surface views and CT views to analyze the deformation of the lower limb and plan the implantation. The components were positioned in an individualized manner to realign the lower limb and provide ligament balance based on bone landmarks. Final component positioning was analyzed in the three planes with a postoperative CT scan. The preoperative and 1 year follow-up IKS and WOMAC scores were collected and compared. All the cutting guides were stable and functional. Femoral component planning was reproduced with 0 ± 2 precision in the frontal plane (94%± 3), 2 ± 3 in the sagittal plane, and 0 ± 2 in the transverse plane. The precision of the tibial component was reproduced with 0 ± 2 precision in the frontal plane (93%± 3) and 0 ± 4 in the sagittal plane. The HKA angle increased from 177 ± 7 preoperatively to 180 ± 3 at 1 year of follow-up. The IKS and WOMAC scores were significantly improved at 1 year (P<0.0001). The Knee-Plan system can be a realistic, simple, and reliable alternative to conventional cutting guides and to computer-assisted surgery for TKA implantation. IV; prospective cohort study. Copyright © 2014. Published by Elsevier Masson SAS.

  17. Automatic building identification under bomb damage conditions

    NASA Astrophysics Data System (ADS)

    Woodley, Robert; Noll, Warren; Barker, Joseph; Wunsch, Donald C., II

    2009-05-01

    Given the vast amount of image intelligence utilized in support of planning and executing military operations, a passive automated image processing capability for target identification is urgently required. Furthermore, transmitting large image streams from remote locations would quickly use available band width (BW) precipitating the need for processing to occur at the sensor location. This paper addresses the problem of automatic target recognition for battle damage assessment (BDA). We utilize an Adaptive Resonance Theory approach to cluster templates of target buildings. The results show that the network successfully classifies targets from non-targets in a virtual test bed environment.

  18. Challenges for Successful Planning of Open and Distance Learning (ODL) : A Template Analysis

    ERIC Educational Resources Information Center

    Minnaar, Ansie

    2013-01-01

    How to plan an open and distance learning (ODL) unit in higher education is not clearly described in the literature. A number of ODL facilities at residential universities have not been successful because of a lack of planning or because of failure to ensure that all the different systems for ODL delivery were in place and functioning. This paper…

  19. The accuracy and the safety of individualized 3D printing screws insertion templates for cervical screw insertion.

    PubMed

    Deng, Ting; Jiang, Minghui; Lei, Qing; Cai, Lihong; Chen, Li

    2016-12-01

    Clinical trial for cervical screw insertion by using individualized 3-dimensional (3D) printing screw insertion templates device. The objective of this study is to evaluate the safety and accuracy of the individualized 3D printing screw insertion template in the cervical spine. Ten patients who underwent posterior cervical fusion surgery with cervical pedicle screws, laminar screws or lateral mass screws between December 2014 and December 2015 were involved in this study. The patients were examined by CT scan before operation. The individualized 3D printing templates were made with photosensitive resin by a 3D printing system to ensure the screw shafts entered the vertebral body without breaking the pedicle or lamina cortex. The templates were sterilized by a plasma sterilizer and used during the operation. The accuracy and the safety of the templates were evaluated by CT scans at the screw insertion levels after operation. The accuracy of this patient-specific template technique was demonstrated. Only one screw axis greatly deviated from the planned track and breached the cortex of the pedicle because the template was split by rough handling and then we inserted the screws under the fluoroscopy. The remaining screws were inserted in the track as preoperative design and the screw axis deviated by less than 2 mm. Vascular or neurologic complications or injuries did not happen. And no infection, broken nails, fracture of bone structure, or screw pullout occurred. This study verified the safety and the accuracy of the individualized 3D printing screw insertion templates in the cervical spine as a kind of intraoperative screw navigation. This individualized 3D printing screw insertion template was user-friendly, moderate cost, and enabled a radiation-free cervical screw insertion.

  20. Optimized Periocular Template Selection for Human Recognition

    PubMed Central

    Sa, Pankaj K.; Majhi, Banshidhar

    2013-01-01

    A novel approach for selecting a rectangular template around periocular region optimally potential for human recognition is proposed. A comparatively larger template of periocular image than the optimal one can be slightly more potent for recognition, but the larger template heavily slows down the biometric system by making feature extraction computationally intensive and increasing the database size. A smaller template, on the contrary, cannot yield desirable recognition though the smaller template performs faster due to low computation for feature extraction. These two contradictory objectives (namely, (a) to minimize the size of periocular template and (b) to maximize the recognition through the template) are aimed to be optimized through the proposed research. This paper proposes four different approaches for dynamic optimal template selection from periocular region. The proposed methods are tested on publicly available unconstrained UBIRISv2 and FERET databases and satisfactory results have been achieved. Thus obtained template can be used for recognition of individuals in an organization and can be generalized to recognize every citizen of a nation. PMID:23984370

  1. Verification of Dosimetric Commissioning Accuracy of Intensity Modulated Radiation Therapy and Volumetric Modulated Arc Therapy Delivery using Task Group-119 Guidelines.

    PubMed

    Kaviarasu, Karunakaran; Nambi Raj, N Arunai; Hamid, Misba; Giri Babu, A Ananda; Sreenivas, Lingampally; Murthy, Kammari Krishna

    2017-01-01

    The purpose of this study is to verify the accuracy of the commissioning of intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) based on the recommendation of the American Association of Physicists in Medicine Task Group 119 (TG-119). TG-119 proposes a set of clinical test cases to verify the accuracy of IMRT planning and delivery system. For these test cases, we generated two sets of treatment plans, the first plan using 7-9 IMRT fields and a second plan utilizing two-arc VMAT technique for both 6 MV and 15 MV photon beams. The template plans of TG-119 were optimized and calculated by Varian Eclipse Treatment Planning System (version 13.5). Dose prescription and planning objectives were set according to the TG-119 goals. The point dose (mean dose to the contoured chamber volume) at the specified positions/locations was measured using compact (CC-13) ion chamber. The composite planar dose was measured with IMatriXX Evaluation 2D array with OmniPro IMRT Software (version 1.7b). The per-field relative gamma was measured using electronic portal imaging device in a way similar to the routine pretreatment patient-specific quality assurance. Our planning results are compared with the TG-119 data. Point dose and fluence comparison data where within the acceptable confident limit. From the obtained data in this study, we conclude that the commissioning of IMRT and VMAT delivery were found within the limits of TG-119.

  2. Verification of Dosimetric Commissioning Accuracy of Intensity Modulated Radiation Therapy and Volumetric Modulated Arc Therapy Delivery using Task Group-119 Guidelines

    PubMed Central

    Kaviarasu, Karunakaran; Nambi Raj, N. Arunai; Hamid, Misba; Giri Babu, A. Ananda; Sreenivas, Lingampally; Murthy, Kammari Krishna

    2017-01-01

    Aim: The purpose of this study is to verify the accuracy of the commissioning of intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) based on the recommendation of the American Association of Physicists in Medicine Task Group 119 (TG-119). Materials and Methods: TG-119 proposes a set of clinical test cases to verify the accuracy of IMRT planning and delivery system. For these test cases, we generated two sets of treatment plans, the first plan using 7–9 IMRT fields and a second plan utilizing two-arc VMAT technique for both 6 MV and 15 MV photon beams. The template plans of TG-119 were optimized and calculated by Varian Eclipse Treatment Planning System (version 13.5). Dose prescription and planning objectives were set according to the TG-119 goals. The point dose (mean dose to the contoured chamber volume) at the specified positions/locations was measured using compact (CC-13) ion chamber. The composite planar dose was measured with IMatriXX Evaluation 2D array with OmniPro IMRT Software (version 1.7b). The per-field relative gamma was measured using electronic portal imaging device in a way similar to the routine pretreatment patient-specific quality assurance. Results: Our planning results are compared with the TG-119 data. Point dose and fluence comparison data where within the acceptable confident limit. Conclusion: From the obtained data in this study, we conclude that the commissioning of IMRT and VMAT delivery were found within the limits of TG-119. PMID:29296041

  3. Treatment planning for SBRT using automated field delivery: A case study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ritter, Timothy A., E-mail: timritte@med.umich.edu; Department of Radiation Oncology, Veterans Affairs Ann Arbor Health Care System, Ann Arbor, MI; Owen, Dawn

    Stereotactic body radiation therapy (SBRT) treatment planning and delivery can be accomplished using a variety of techniques that achieve highly conformal dose distributions. Herein, we describe a template-based automated treatment field approach that enables rapid delivery of more than 20 coplanar fields. A case study is presented to demonstrate how modest adaptations to traditional SBRT planning can be implemented to take clinical advantage of this technology. Treatment was planned for a left-sided lung lesion adjacent to the chest wall using 25 coplanar treatment fields spaced at 11° intervals. The plan spares the contralateral lung and is in compliance with themore » conformality standards set forth in Radiation Therapy and Oncology Group protocol 0915, and the dose tolerances found in the report of the American Association of Physicists in Medicine Task Group 101. Using a standard template, treatment planning was accomplished in less than 20 minutes, and each 10 Gy fraction was delivered in approximately 5.4 minutes. For those centers equipped with linear accelerators capable of automated treatment field delivery, the use of more than 20 coplanar fields is a viable SBRT planning approach and yields excellent conformality and quality combined with rapid planning and treatment delivery. Although the case study discusses a laterally located lung lesion, this technique can be applied to centrally located tumors with similar results.« less

  4. Performance Evaluation of Fusing Protected Fingerprint Minutiae Templates on the Decision Level

    PubMed Central

    Yang, Bian; Busch, Christoph; de Groot, Koen; Xu, Haiyun; Veldhuis, Raymond N. J.

    2012-01-01

    In a biometric authentication system using protected templates, a pseudonymous identifier is the part of a protected template that can be directly compared. Each compared pair of pseudonymous identifiers results in a decision testing whether both identifiers are derived from the same biometric characteristic. Compared to an unprotected system, most existing biometric template protection methods cause to a certain extent degradation in biometric performance. Fusion is therefore a promising way to enhance the biometric performance in template-protected biometric systems. Compared to feature level fusion and score level fusion, decision level fusion has not only the least fusion complexity, but also the maximum interoperability across different biometric features, template protection and recognition algorithms, templates formats, and comparison score rules. However, performance improvement via decision level fusion is not obvious. It is influenced by both the dependency and the performance gap among the conducted tests for fusion. We investigate in this paper several fusion scenarios (multi-sample, multi-instance, multi-sensor, multi-algorithm, and their combinations) on the binary decision level, and evaluate their biometric performance and fusion efficiency on a multi-sensor fingerprint database with 71,994 samples. PMID:22778583

  5. Robotic Assistance for Ultrasound-Guided Prostate Brachytherapy

    PubMed Central

    Fichtinger, Gabor; Fiene, Jonathan P.; Kennedy, Christopher W.; Kronreif, Gernot; Iordachita, Iulian; Song, Danny Y.; Burdette, Everette C.; Kazanzides, Peter

    2016-01-01

    We present a robotically assisted prostate brachytherapy system and test results in training phantoms and Phase-I clinical trials. The system consists of a transrectal ultrasound (TRUS) and a spatially co-registered robot, fully integrated with an FDA-approved commercial treatment planning system. The salient feature of the system is a small parallel robot affixed to the mounting posts of the template. The robot replaces the template interchangeably, using the same coordinate system. Established clinical hardware, workflow and calibration remain intact. In all phantom experiments, we recorded the first insertion attempt without adjustment. All clinically relevant locations in the prostate were reached. Non-parallel needle trajectories were achieved. The pre-insertion transverse and rotational errors (measured with a Polaris optical tracker relative to the template’s coordinate frame) were 0.25mm (STD=0.17mm) and 0.75° (STD=0.37°). In phantoms, needle tip placement errors measured in TRUS were 1.04mm (STD=0.50mm). A Phase-I clinical feasibility and safety trial has been successfully completed with the system. We encountered needle tip positioning errors of a magnitude greater than 4mm in only 2 out of 179 robotically guided needles, in contrast to manual template guidance where errors of this magnitude are much more common. Further clinical trials are necessary to determine whether the apparent benefits of the robotic assistant will lead to improvements in clinical efficacy and outcomes. PMID:18650122

  6. 75 FR 29570 - Notice of Proposed Information Collection for Public Comment Public Housing Agency Plan Revisions...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-26

    ... PHA and the goals, objectives, policies, or programs for servicing victims of domestic violence, dating violence, sexual assault, or stalking and submit the template every 5 years. Qualified PHAs no... Violence Against Women Act (Section 5.3); incorporates a table identifying all Annual PHA Plan elements...

  7. Making a Meal out of Mathematics

    ERIC Educational Resources Information Center

    Penny, Robert Ward

    2010-01-01

    When planning a lesson, many teachers will start by listing content-based objectives; after all, this is how the majority of textbooks, schemes of work and lesson planning templates are constructed. This is understandable, as for many years now teachers have been legally required to teach the national curriculum which was a list of content-based…

  8. Template protection and its implementation in 3D face recognition systems

    NASA Astrophysics Data System (ADS)

    Zhou, Xuebing

    2007-04-01

    As biometric recognition systems are widely applied in various application areas, security and privacy risks have recently attracted the attention of the biometric community. Template protection techniques prevent stored reference data from revealing private biometric information and enhance the security of biometrics systems against attacks such as identity theft and cross matching. This paper concentrates on a template protection algorithm that merges methods from cryptography, error correction coding and biometrics. The key component of the algorithm is to convert biometric templates into binary vectors. It is shown that the binary vectors should be robust, uniformly distributed, statistically independent and collision-free so that authentication performance can be optimized and information leakage can be avoided. Depending on statistical character of the biometric template, different approaches for transforming biometric templates into compact binary vectors are presented. The proposed methods are integrated into a 3D face recognition system and tested on the 3D facial images of the FRGC database. It is shown that the resulting binary vectors provide an authentication performance that is similar to the original 3D face templates. A high security level is achieved with reasonable false acceptance and false rejection rates of the system, based on an efficient statistical analysis. The algorithm estimates the statistical character of biometric templates from a number of biometric samples in the enrollment database. For the FRGC 3D face database, the small distinction of robustness and discriminative power between the classification results under the assumption of uniquely distributed templates and the ones under the assumption of Gaussian distributed templates is shown in our tests.

  9. Optimization of spine surgery planning with 3D image templating tools

    NASA Astrophysics Data System (ADS)

    Augustine, Kurt E.; Huddleston, Paul M.; Holmes, David R., III; Shridharani, Shyam M.; Robb, Richard A.

    2008-03-01

    The current standard of care for patients with spinal disorders involves a thorough clinical history, physical exam, and imaging studies. Simple radiographs provide a valuable assessment but prove inadequate for surgery planning because of the complex 3-dimensional anatomy of the spinal column and the close proximity of the neural elements, large blood vessels, and viscera. Currently, clinicians still use primitive techniques such as paper cutouts, pencils, and markers in an attempt to analyze and plan surgical procedures. 3D imaging studies are routinely ordered prior to spine surgeries but are currently limited to generating simple, linear and angular measurements from 2D views orthogonal to the central axis of the patient. Complex spinal corrections require more accurate and precise calculation of 3D parameters such as oblique lengths, angles, levers, and pivot points within individual vertebra. We have developed a clinician friendly spine surgery planning tool which incorporates rapid oblique reformatting of each individual vertebra, followed by interactive templating for 3D placement of implants. The template placement is guided by the simultaneous representation of multiple 2D section views from reformatted orthogonal views and a 3D rendering of individual or multiple vertebrae enabling superimposition of virtual implants. These tools run efficiently on desktop PCs typically found in clinician offices or workrooms. A preliminary study conducted with Mayo Clinic spine surgeons using several actual cases suggests significantly improved accuracy of pre-operative measurements and implant localization, which is expected to increase spinal procedure efficiency and safety, and reduce time and cost of the operation.

  10. Photogrammetric determination of discrepancies between actual and planned position of dental implants

    NASA Astrophysics Data System (ADS)

    Forlani, G.; Rivara, F.

    2014-05-01

    The paper describes the design and testing of a photogrammetric measurement protocol set up to determine the discrepancies between the planned and actual position of computer-guided template-based dental implants. Two moulds with the implants positioned in pre- and post- intervention are produced and separately imaged with a highly redundant block of convergent images; the model with the implants is positioned on a steel frame with control points and with suitable targets attached. The theoretical accuracy of the system is better than 20 micrometers and 0.3-0.4° respectively for positions of implants and directions of implant axes. In order to compare positions and angles between the planned and actual position of an implant, coordinates and axes directions are brought to a common reference system with a Helmert transformation. A procedure for comparison of positions and directions to identify out-of-tolerance discrepancies is presented; a numerical simulation study shows the effectiveness of the procedure in identifying the implants with significant discrepancies between pre- and post- intervention.

  11. An influenza A virus agglutination test using antibody-like polymers.

    PubMed

    Sukjee, Wannisa; Thitithanyanont, Arunee; Wiboon-Ut, Suwimon; Lieberzeit, Peter A; Paul Gleeson, M; Navakul, Krongkaew; Sangma, Chak

    2017-10-01

    Antibodies are commonly used in diagnostic routines to identify pathogens. The testing protocols are relatively simple, requiring a certain amount of a specific antibody to detect its corresponding pathogen. Antibody functionality can be mimicked by synthesizing molecularly imprinted polymers (MIPs), i.e. polymers that can selectively recognize a given template structure. Thus, MIPs are sometimes termed 'plastic antibody (PA)'. In this study, we have synthesized new granular MIPs using influenza A virus templates by precipitation polymerization. The selective binding of influenza A to the MIP particles was assessed and subsequently contrasted with other viruses. The affinities of influenza A virus towards the MIP was estimated based on an agglutination test by measuring the amount of influenza subtypes absorbed onto the MIPs. The MIPs produced using the H1N1 template showed specific reactivity to H1N1 while those produced using H5N1 and H3N2 templates showed cross-reactivity.

  12. An automated method for modeling proteins on known templates using distance geometry.

    PubMed

    Srinivasan, S; March, C J; Sudarsanam, S

    1993-02-01

    We present an automated method incorporated into a software package, FOLDER, to fold a protein sequence on a given three-dimensional (3D) template. Starting with the sequence alignment of a family of homologous proteins, tertiary structures are modeled using the known 3D structure of one member of the family as a template. Homologous interatomic distances from the template are used as constraints. For nonhomologous regions in the model protein, the lower and the upper bounds for the interatomic distances are imposed by steric constraints and the globular dimensions of the template, respectively. Distance geometry is used to embed an ensemble of structures consistent with these distance bounds. Structures are selected from this ensemble based on minimal distance error criteria, after a penalty function optimization step. These structures are then refined using energy optimization methods. The method is tested by simulating the alpha-chain of horse hemoglobin using the alpha-chain of human hemoglobin as the template and by comparing the generated models with the crystal structure of the alpha-chain of horse hemoglobin. We also test the packing efficiency of this method by reconstructing the atomic positions of the interior side chains beyond C beta atoms of a protein domain from a known 3D structure. In both test cases, models retain the template constraints and any additionally imposed constraints while the packing of the interior residues is optimized with no short contacts or bond deformations. To demonstrate the use of this method in simulating structures of proteins with nonhomologous disulfides, we construct a model of murine interleukin (IL)-4 using the NMR structure of human IL-4 as the template. The resulting geometry of the nonhomologous disulfide in the model structure for murine IL-4 is consistent with standard disulfide geometry.

  13. Application of digital diagnostic impression, virtual planning, and computer-guided implant surgery for a CAD/CAM-fabricated, implant-supported fixed dental prosthesis: a clinical report.

    PubMed

    Stapleton, Brandon M; Lin, Wei-Shao; Ntounis, Athanasios; Harris, Bryan T; Morton, Dean

    2014-09-01

    This clinical report demonstrated the use of an implant-supported fixed dental prosthesis fabricated with a contemporary digital approach. The digital diagnostic data acquisition was completed with a digital diagnostic impression with an intraoral scanner and cone-beam computed tomography with a prefabricated universal radiographic template to design a virtual prosthetically driven implant surgical plan. A surgical template fabricated with computer-aided design and computer-aided manufacturing (CAD/CAM) was used to perform computer-guided implant surgery. The definitive digital data were then used to design the definitive CAD/CAM-fabricated fixed dental prosthesis. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  14. Creating Shape Templates for Patient Specific Biventricular Modeling in Congenital Heart Disease

    PubMed Central

    Gilbert, Kathleen; Farrar, Genevieve; Cowan, Brett R.; Suinesiaputra, Avan; Occleshaw, Christopher; Pontré, Beau; Perry, James; Hegde, Sanjeet; Marsden, Alison; Omens, Jeff; McCulloch, Andrew; Young, Alistair A.

    2018-01-01

    Survival rates for infants with congenital heart disease (CHD) are improving, resulting in a growing population of adults with CHD. However, the analysis of left and right ventricular function is very time-consuming owing to the variety of congenital morphologies. Efficient customization of patient geometry and function depends on high quality shape templates specifically designed for the application. In this paper, we combine a method for creating finite element shape templates with an interactive template customization to patient MRI examinations. This enables different templates to be chosen depending on patient morphology. To demonstrate this pipeline, a new biventricular template with 162 elements was created and tested in place of an existing 82-element template. The method was able to provide fast interactive biventricular analysis with 0.31 sec per edit response time. The new template was customized to 13 CHD patients with similar biventricular topology, showing improved performance over the previous template and good agreement with clinical indices. PMID:26736353

  15. 78 FR 50075 - Statewide Communication Interoperability Plan Template and Annual Progress Report

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-16

    ... of Cybersecurity and Communications (CS&C), Office of Emergency Communications (OEC), will submit the... Directorate, Office of Cybersecurity and Communications, Office of Emergency Communications. Title: Statewide...

  16. Coordinating sensing and local navigation

    NASA Technical Reports Server (NTRS)

    Slack, Marc G.

    1991-01-01

    Based on Navigation Templates (or NaTs), this work presents a new paradigm for local navigation which addresses the noisy and uncertain nature of sensor data. Rather than creating a new navigation plan each time the robot's perception of the world changes, the technique incorporates perceptual changes directly into the existing navigation plan. In this way, the robot's navigation plan is quickly and continuously modified, resulting in actions that remain coordinated with its changing perception of the world.

  17. Dynamic traversal of large gaps by insects and legged robots reveals a template.

    PubMed

    Gart, Sean W; Yan, Changxin; Othayoth, Ratan; Ren, Zhiyi; Li, Chen

    2018-02-02

    It is well known that animals can use neural and sensory feedback via vision, tactile sensing, and echolocation to negotiate obstacles. Similarly, most robots use deliberate or reactive planning to avoid obstacles, which relies on prior knowledge or high-fidelity sensing of the environment. However, during dynamic locomotion in complex, novel, 3D terrains, such as a forest floor and building rubble, sensing and planning suffer bandwidth limitation and large noise and are sometimes even impossible. Here, we study rapid locomotion over a large gap-a simple, ubiquitous obstacle-to begin to discover the general principles of the dynamic traversal of large 3D obstacles. We challenged the discoid cockroach and an open-loop six-legged robot to traverse a large gap of varying length. Both the animal and the robot could dynamically traverse a gap as large as one body length by bridging the gap with its head, but traversal probability decreased with gap length. Based on these observations, we developed a template that accurately captured body dynamics and quantitatively predicted traversal performance. Our template revealed that a high approach speed, initial body pitch, and initial body pitch angular velocity facilitated dynamic traversal, and successfully predicted a new strategy for using body pitch control that increased the robot's maximal traversal gap length by 50%. Our study established the first template of dynamic locomotion beyond planar surfaces, and is an important step in expanding terradynamics into complex 3D terrains.

  18. 101 Templates for School Business Administration. For Use with Lotus 1-2-3.

    ERIC Educational Resources Information Center

    Graczyk, Sandra L.; Faux, James H.

    In most school districts, the chief business official is involved in some aspect of a variety of support functions. This book provides 101 ready-made, field-tested computerized templates of applications commonly used in school business administration. The 101 school business applications and corresponding templates are described in the text and…

  19. GalaxyTBM: template-based modeling by building a reliable core and refining unreliable local regions.

    PubMed

    Ko, Junsu; Park, Hahnbeom; Seok, Chaok

    2012-08-10

    Protein structures can be reliably predicted by template-based modeling (TBM) when experimental structures of homologous proteins are available. However, it is challenging to obtain structures more accurate than the single best templates by either combining information from multiple templates or by modeling regions that vary among templates or are not covered by any templates. We introduce GalaxyTBM, a new TBM method in which the more reliable core region is modeled first from multiple templates and less reliable, variable local regions, such as loops or termini, are then detected and re-modeled by an ab initio method. This TBM method is based on "Seok-server," which was tested in CASP9 and assessed to be amongst the top TBM servers. The accuracy of the initial core modeling is enhanced by focusing on more conserved regions in the multiple-template selection and multiple sequence alignment stages. Additional improvement is achieved by ab initio modeling of up to 3 unreliable local regions in the fixed framework of the core structure. Overall, GalaxyTBM reproduced the performance of Seok-server, with GalaxyTBM and Seok-server resulting in average GDT-TS of 68.1 and 68.4, respectively, when tested on 68 single-domain CASP9 TBM targets. For application to multi-domain proteins, GalaxyTBM must be combined with domain-splitting methods. Application of GalaxyTBM to CASP9 targets demonstrates that accurate protein structure prediction is possible by use of a multiple-template-based approach, and ab initio modeling of variable regions can further enhance the model quality.

  20. Duocentric® reversed shoulder prosthesis and Personal Fit® templates: innovative strategies to optimize prosthesis positioning and prevent scapular notching.

    PubMed

    Trouilloud, P; Gonzalvez, M; Martz, P; Charles, H; Handelberg, F; Nyffeler, R W; Baulot, E

    2014-05-01

    We describe our experience with a new system of patient-specific template called Personal Fit(®), which is unique in shoulder surgery and used in combination with Duocentric(®) prosthesis. The reverse prosthesis's concept is the invention of Paul Grammont, developed with Grammont's team of Dijon University as from 1981, which led to the first reversed total shoulder prosthesis called Trumpet in 1985. The Duocentric(®) prosthesis developed in 2001 is the third-generation prosthesis, coming from the Trumpet and the second-generation prosthesis Delta(®) (DePuy). This prosthesis provides a novel solution to the notching problem with an inferior overhang integrated onto the glenoid baseplate. Personal Fit(®) system is based on reconstructing the shoulder joint bones in three dimensions using CT scan data, placing a landmark on the scapula and locating points on the glenoid and humerus. That will be used as a reference for the patient-specific templates. We study the glenoid position planned with Personal Fit(®) software relative to native glenoid position in 30 cases. On average, the difference between the planned retroversion (or anteversion in one case) and native retroversion was 8.6°.

  1. Asymmetric segregation of template DNA strands in basal-like human breast cancer cell lines

    PubMed Central

    2013-01-01

    Background and methods Stem or progenitor cells from healthy tissues have the capacity to co-segregate their template DNA strands during mitosis. Here, we set out to test whether breast cancer cell lines also possess the ability to asymmetrically segregate their template DNA strands via non-random chromosome co-segregation, and whether this ability correlates with certain properties attributed to breast cancer stem cells (CSCs). We quantified the frequency of asymmetric segregation of template DNA strands in 12 human breast cancer cell lines, and correlated the frequency to molecular subtype, CD44+/CD24-/lo phenotype, and invasion/migration ability. We tested if co-culture with human mesenchymal stem cells, which are known to increase self-renewal, can alter the frequency of asymmetric segregation of template DNA in breast cancer. Results We found a positive correlation between asymmetric segregation of template DNA and the breast cancer basal-like and claudin-low subtypes. There was an inverse correlation between asymmetric segregation of template DNA and Her2 expression. Breast cancer samples with evidence of asymmetric segregation of template DNA had significantly increased invasion and borderline significantly increased migration abilities. Samples with high CD44+/CD24-/lo surface expression were more likely to harbor a consistent population of cells that asymmetrically segregated its template DNA; however, symmetric self-renewal was enriched in the CD44+/CD24-/lo population. Co-culturing breast cancer cells with human mesenchymal stem cells expanded the breast CSC pool and decreased the frequency of asymmetric segregation of template DNA. Conclusions Breast cancer cells within the basal-like subtype can asymmetrically segregate their template DNA strands through non-random chromosome segregation. The frequency of asymmetric segregation of template DNA can be modulated by external factors that influence expansion or self-renewal of CSC populations. Future studies to uncover the underlying mechanisms driving asymmetric segregation of template DNA and dictating cell fate at the time of cell division may explain how CSCs are maintained in tumors. PMID:24238140

  2. Safe and accurate midcervical pedicle screw insertion procedure with the patient-specific screw guide template system.

    PubMed

    Kaneyama, Shuichi; Sugawara, Taku; Sumi, Masatoshi

    2015-03-15

    Clinical trial for midcervical pedicle screw insertion using a novel patient-specific intraoperative screw guiding device. To evaluate the availability of the "Screw Guide Template" (SGT) system for insertion of midcervical pedicle screws. Despite many efforts for accurate midcervical pedicle screw insertion, there still remain unacceptable rate of screw malpositioning that might cause neurovascular injuries. We developed patient-specific SGT system for safe and accurate intraoperative screw navigation tool and have reported its availability for the screw insertion to C2 vertebra and thoracic spine. Preoperatively, the bone image on computed tomography was analyzed and the trajectories of the screws were designed in 3-dimensional format. Three types of templates were created for each lamina: location template, drill guide template, and screw guide template. During the operations, after engaging the templates directly with the laminae, drilling, tapping, and screwing were performed with each template. We placed 80 midcervical pedicle screws for 20 patients. The accuracy and safety of the screw insertion by SGT system were evaluated using postoperative computed tomographic scan by calculation of screw deviation from the preplanned trajectory and evaluation of screw breach of pedicle wall. All templates fitted the laminae and screw navigation procedures proceeded uneventfully. All screws were inserted accurately with the mean screw deviation from planned trajectory of 0.29 ± 0.31 mm and no neurovascular complication was experienced. We demonstrated that our SGT system could support the precise screw insertion in midcervical pedicle. SGT prescribes the safe screw trajectory in a 3-dimensional manner and the templates fit and lock directly to the target laminae, which prevents screwing error along with the change of spinal alignment during the surgery. These advantages of the SGT system guarantee the high accuracy in screw insertion, which allowed surgeons to insert cervical pedicle screws safely. 3.

  3. Biological Aerosol Test Method and Personal Protective Equipment (PPE) Decon

    DTIC Science & Technology

    2011-05-01

    supply to the porous tube diluter. This stops all air into the LSAT. 6. Power off the vacuum pump and the compressed air supply. 22 Distribution...Experiment from Template from the menu. 10. Scroll down the template list until you find APHL Flu Assay 04272009. 11. Highlight the test, then click

  4. Consensus guidelines: improving the delivery of clinical preventive services.

    PubMed

    Ayres, Cynthia G; Griffith, Hurdis M

    2008-01-01

    Medical directors from the largest competing health plans in the state came together in a noncompetitive way to collaborate on improving the delivery of clinical preventive service (CPS) among their provider base. They identified one consistent set of CPS guidelines based on U.S. Preventive Services Task Force recommendations, the health plan consensus guidelines (HPCG), that they could endorse as priority for guideline implementation. The purposes of this study were to assess clinicians' knowledge and use of CPS recommendations as a guide to delivering preventive care services to their patients and, most importantly, to test the effectiveness of providing the HPCG to clinicians in an effort to increase knowledge and use of CPS guidelines. Within-subjects repeated-measures design was used. We hypothesized an increase in clinician's knowledge and use of CPS after the provision of the HPCG. Survey methodology, including two surveys that assessed clinicians' knowledge and use of CPS in practice, was used. Health plan clinician databases were obtained from the health plans that participated in the development of the HPCG. Health plan clinicians directly involved in delivering preventive services were invited to participate in the study. Final sample included 163 clinicians. Spearman's rho correlation coefficients were determined to examine the relationships between clinician's knowledge and clinician's use of CPS guidelines. Differences between knowledge and use of CPS before and after HPCG were examined by t tests. No difference was found in the familiarity with U.S. Preventive Services Task Force guidelines before and after receipt of HPCG. However, clinician's use increased significantly. A consistent set of CPS guidelines provided by competing health plans can improve the delivery of CPS among contracted health plan clinicians. This approach provides a template for competing health plans nationwide to come to consensus on guidelines that support clinicians in the delivery of CPS ().

  5. RECURSIVE PROTEIN MODELING: A DIVIDE AND CONQUER STRATEGY FOR PROTEIN STRUCTURE PREDICTION AND ITS CASE STUDY IN CASP9

    PubMed Central

    CHENG, JIANLIN; EICKHOLT, JESSE; WANG, ZHENG; DENG, XIN

    2013-01-01

    After decades of research, protein structure prediction remains a very challenging problem. In order to address the different levels of complexity of structural modeling, two types of modeling techniques — template-based modeling and template-free modeling — have been developed. Template-based modeling can often generate a moderate- to high-resolution model when a similar, homologous template structure is found for a query protein but fails if no template or only incorrect templates are found. Template-free modeling, such as fragment-based assembly, may generate models of moderate resolution for small proteins of low topological complexity. Seldom have the two techniques been integrated together to improve protein modeling. Here we develop a recursive protein modeling approach to selectively and collaboratively apply template-based and template-free modeling methods to model template-covered (i.e. certain) and template-free (i.e. uncertain) regions of a protein. A preliminary implementation of the approach was tested on a number of hard modeling cases during the 9th Critical Assessment of Techniques for Protein Structure Prediction (CASP9) and successfully improved the quality of modeling in most of these cases. Recursive modeling can signicantly reduce the complexity of protein structure modeling and integrate template-based and template-free modeling to improve the quality and efficiency of protein structure prediction. PMID:22809379

  6. Utilizing a Pediatric Disaster Coalition Model to Increase Pediatric Critical Care Surge Capacity in New York City.

    PubMed

    Frogel, Michael; Flamm, Avram; Sagy, Mayer; Uraneck, Katharine; Conway, Edward; Ushay, Michael; Greenwald, Bruce M; Pierre, Louisdon; Shah, Vikas; Gaffoor, Mohamed; Cooper, Arthur; Foltin, George

    2017-08-01

    A mass casualty event can result in an overwhelming number of critically injured pediatric victims that exceeds the available capacity of pediatric critical care (PCC) units, both locally and regionally. To address these gaps, the New York City (NYC) Pediatric Disaster Coalition (PDC) was established. The PDC includes experts in emergency preparedness, critical care, surgery, and emergency medicine from 18 of 25 major NYC PCC-capable hospitals. A PCC surge committee created recommendations for making additional PCC beds available with an emphasis on space, staff, stuff (equipment), and systems. The PDC assisted 15 hospitals in creating PCC surge plans by utilizing template plans and site visits. These plans created an additional 153 potential PCC surge beds. Seven hospitals tested their plans through drills. The purpose of this article was to demonstrate the need for planning for disasters involving children and to provide a stepwise, replicable model for establishing a PDC, with one of its primary goals focused on facilitating PCC surge planning. The process we describe for developing a PDC can be replicated to communities of any size, setting, or location. We offer our model as an example for other cities. (Disaster Med Public Health Preparedness. 2017;11:473-478).

  7. Testing sensory evidence against mnemonic templates

    PubMed Central

    Myers, Nicholas E; Rohenkohl, Gustavo; Wyart, Valentin; Woolrich, Mark W; Nobre, Anna C; Stokes, Mark G

    2015-01-01

    Most perceptual decisions require comparisons between current input and an internal template. Classic studies propose that templates are encoded in sustained activity of sensory neurons. However, stimulus encoding is itself dynamic, tracing a complex trajectory through activity space. Which part of this trajectory is pre-activated to reflect the template? Here we recorded magneto- and electroencephalography during a visual target-detection task, and used pattern analyses to decode template, stimulus, and decision-variable representation. Our findings ran counter to the dominant model of sustained pre-activation. Instead, template information emerged transiently around stimulus onset and quickly subsided. Cross-generalization between stimulus and template coding, indicating a shared neural representation, occurred only briefly. Our results are compatible with the proposal that template representation relies on a matched filter, transforming input into task-appropriate output. This proposal was consistent with a signed difference response at the perceptual decision stage, which can be explained by a simple neural model. DOI: http://dx.doi.org/10.7554/eLife.09000.001 PMID:26653854

  8. Computed tomography-based evaluation of template (NobelGuide™)-guided implant positions: a prospective radiological study.

    PubMed

    Vasak, Christoph; Watzak, Georg; Gahleitner, André; Strbac, Georg; Schemper, Michael; Zechner, Werner

    2011-10-01

    This prospective study was intended to evaluate the overall deviation in a clinical treatment setting to provide for quantification of the potential impairment of treatment safety and reliability with computer-assisted, template-guided transgingival implantation. The patient population enrolled (male/female=10/8) presented with partially dentate and edentulous maxillae and mandibles. Overall, 86 implants were placed by two experienced dental surgeons strictly following the NobelGuide™ protocol for template-guided implantation. All patients had a postoperative computed tomography (CT) with identical settings to the preoperative examination. Using the triple scan technique, pre- and postoperative CT data were merged in the Procera planning software, a newly developed procedure - initially presented in 2007 allowing measurement of the deviations at implant shoulder and apex. The deviations measured were an average of 0.43 mm (bucco-lingual), 0.46 mm (mesio-distal) and 0.53 mm (depth) at the level of the implant shoulder and slightly higher at the implant apex with an average of 0.7 mm (bucco-lingual), 0.63 mm (mesio-distal) and 0.52 mm (depth). The maximum deviation of 2.02 mm was encountered in the corono-apical direction. Significantly lower deviations were seen for implants in the anterior region vs. the posterior tooth region (P<0.01, 0.31 vs. 0.5 mm), and deviations were also significantly lower in the mandible than in the maxilla (P=0.04, 0.36 vs. 0.45 mm) in the mesio-distal direction. Moreover, a significant correlation between deviation and mucosal thickness was seen and a learning effect was found over the time period of performance of the surgical procedures. Template-guided implantation will ensure reliable transfer of preoperative computer-assisted planning into surgical practice. With regard to the required verification of treatment reliability of an implantation system with flapless access, all maximum deviations measured in this clinical study were within the safety margins recommended by the planning software. © 2011 John Wiley & Sons A/S.

  9. An Implementation Plan: One-to-One Laptop Program Recommendations for the Pittsgrove Township School District

    ERIC Educational Resources Information Center

    Brodzik, Michael C.

    2012-01-01

    This Executive Position Paper is a one-to-one laptop implementation plan for Pittsgrove Township Schools that can be used as a template for other districts with similar interests. Each of the three chapters fulfills a major purpose. In Chapter One the paper is designed to substantiate the need for the Pittsgrove Township School District to…

  10. Designing Services and Programs for High-Ability Learners. A Guidebook for Gifted Education

    ERIC Educational Resources Information Center

    Purcell, Jeanne H., Ed.; Eckert, Rebecca D., Ed.

    2005-01-01

    This book will help the reader every step of the way with detailed guidelines, practical tips, templates, action plans, and suggestions for strategic planning teams as well as for the sole practitioner. Consolidating the sage advice and up-to-date research of 29 leaders in the field, this comprehensive and highly practical guide takes the…

  11. 3-Dimensional printing guide template assisted percutaneous vertebroplasty: Technical note.

    PubMed

    Li, Jian; Lin, JiSheng; Yang, Yong; Xu, JunChuan; Fei, Qi

    2018-06-01

    Percutaneous vertebroplasty (PVP) is currently considered as an effective treatment for pain caused by acute osteoporotic vertebral compression fracture. Recently, puncture-related complications are increasingly reported. It's important to find a precise technique to reduce the puncture-related complications. We report a case and discussed the novel surgical technique with step-by-step operating procedures, to introduce the precise PVP assisted by a 3-dimensional printing guide template. Based on the preoperative CT scan and infrared scan data, a well-designed individual guide template could be established in a 3-dimensional reconstruction software and printed out by a 3-dimensional printer. In real operation, by matching the guide template to patient's back skin, cement needles' insertion orientation and depth were easily established. Only 14 times C-arm fluoroscopy with HDF mode (total exposure dose was 4.5 mSv) were required during the procedure. The operation took only 17 min. Cement distribution in the vertebral body was very good without any puncture-related complications. Pain was significantly relieved after surgery. In conclusion, the novel precise 3-dimensional printing guide template system may allow (1) comprehensive visualization of the fractured vertebral body and the individual surgical planning, (2) the perfect fitting between skin and guide template to ensure the puncture stability and accuracy, and (3) increased puncture precision and decreased puncture-related complications, surgical time and radiation exposure. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. A novel dental implant guided surgery based on integration of surgical template and augmented reality.

    PubMed

    Lin, Yen-Kun; Yau, Hong-Tzong; Wang, I-Chung; Zheng, Cheng; Chung, Kwok-Hung

    2015-06-01

    Stereoscopic visualization concept combined with head-mounted displays may increase the accuracy of computer-aided implant surgery. The aim of this study was to develop an augmented reality-based dental implant placement system and evaluate the accuracy of the virtually planned versus the actual prepared implant site created in vitro. Four fully edentulous mandibular and four partially edentulous maxillary duplicated casts were used. Six implants were planned in the mandibular and four in the maxillary casts. A total of 40 osteotomy sites were prepared in the casts using stereolithographic template integrated with augmented reality-based surgical simulation. During the surgery, the dentist could be guided accurately through a head-mounted display by superimposing the virtual auxiliary line and the drill stop. The deviation between planned and prepared positions of the implants was measured via postoperative computer tomography generated scan images. Mean and standard deviation of the discrepancy between planned and prepared sites at the entry point, apex, angle, depth, and lateral locations were 0.50 ± 0.33 mm, 0.96 ± 0.36 mm, 2.70 ± 1.55°, 0.33 ± 0.27 mm, and 0.86 ± 0.34 mm, respectively, for the fully edentulous mandible, and 0.46 ± 0.20 mm, 1.23 ± 0.42 mm, 3.33 ± 1.42°, 0.48 ± 0.37 mm, and 1.1 ± 0.39 mm, respectively, for the partially edentulous maxilla. There was a statistically significant difference in the apical deviation between maxilla and mandible in this surgical simulation (p < .05). Deviation of implant placement from planned position was significantly reduced by integrating surgical template and augmented reality technology. © 2013 Wiley Periodicals, Inc.

  13. Fan fault diagnosis based on symmetrized dot pattern analysis and image matching

    NASA Astrophysics Data System (ADS)

    Xu, Xiaogang; Liu, Haixiao; Zhu, Hao; Wang, Songling

    2016-07-01

    To detect the mechanical failure of fans, a new diagnostic method based on the symmetrized dot pattern (SDP) analysis and image matching is proposed. Vibration signals of 13 kinds of running states are acquired on a centrifugal fan test bed and reconstructed by the SDP technique. The SDP pattern templates of each running state are established. An image matching method is performed to diagnose the fault. In order to improve the diagnostic accuracy, the single template, multiple templates and clustering fault templates are used to perform the image matching.

  14. Accuracy and reproducibility of preoperative three-dimensional planning for total hip arthroplasty using biplanar low-dose radiographs : A pilot study.

    PubMed

    Mainard, D; Barbier, O; Knafo, Y; Belleville, R; Mainard-Simard, L; Gross, J-B

    2017-06-01

    In total hip arthroplasty (THA), the acetabular cup and femoral stem must be correctly sized and positioned to avoid intraoperative and postoperative complications, achieve good functional outcomes and ensure long-term survival. Current two-dimensional (2D) techniques do not provide sufficient accuracy, while low-dose biplanar X-rays (EOS) had not been assessed in this indication. Therefore, we performed a case-control study to : (1) evaluate the prediction of stem and cup size for a new 3D planning technique (stereoradiographic imaging plus 3D modeling) in comparison to 2D templating on film radiographs and (2) evaluate the accuracy and reproducibility of this 3D technique for preoperative THA planning. Accuracy and reproducibility are better with the 3D vs. 2D method. Stem and cup sizes were retrospectively determined by two senior surgeons, twice, for a total of 31 unilateral primary THA patients in this pilot study, using 3D preplanning software on low-dose biplanar X-rays and with 2D templating on conventional anteroposterior (AP) film radiographs. Patients with a modular neck or dual-mobility prosthesis were excluded. All patients but one had primary osteoarthritis; one following trauma did not have a cup implanted. The retrospectively planned sizes were compared to the sizes selected during surgery, and intraclass coefficients (ICC) calculated. 3D planning predicted stem size more accurately than 2D templating: stem sizes were planned within one size in 26/31 (84%) of cases in 3D versus 21/31 (68%) in 2D (P=0.04). 3D and 2D planning accuracies were not significantly different for cup size: cup sizes were planned within one size in 28/30 (92%) of cases in 3D versus 26/30 (87%) in 2D (P=0.30). ICC for stem size were 0.88 vs. 0.91 for 3D and 2D, respectively. Inter-operator ICCs for cup size were 0.84 vs. 0.71, respectively. Repetitions of the 3D planning were within one size (except one stem), with the majority predicting the same size. Increased accuracy in 3D may be due to the use of actual size (non-magnified) images, and judging fit on AP and lateral images simultaneously. Results for other implant components may differ from those presented. Size selection may improve further with planning experience, based on a feedback loop between planning and surgical execution. Level III. Retrospective case-control study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  15. Readability of patient discharge instructions with and without the use of electronically available disease-specific templates.

    PubMed

    Mueller, Stephanie K; Giannelli, Kyla; Boxer, Robert; Schnipper, Jeffrey L

    2015-07-01

    Low health literacy is common, leading to patient vulnerability during hospital discharge, when patients rely on written health instructions. We aimed to examine the impact of the use of electronic, patient-friendly, templated discharge instructions on the readability of discharge instructions provided to patients at discharge. We performed a retrospective cohort study of 233 patients discharged from a large tertiary care hospital to their homes following the implementation of a web-based "discharge module," which included the optional use of diagnosis-specific templated discharge instructions. We compared the readability of discharge instructions, as measured by the Flesch Reading Ease Level test (FREL, on a 0-100 scale, with higher scores indicating greater readability) and the Flesch-Kincaid Grade Level test (FKGL, measured in grade levels), between discharges that used templated instructions (with or without modification) versus discharges that used clinician-generated instructions (with or without available templated instructions for the specific discharge diagnosis). Templated discharge instructions were provided to patients in 45% of discharges. Of the 55% of patients that received clinician-generated discharge instructions, the majority (78.1%) had no available templated instruction for the specific discharge diagnosis. Templated discharge instructions had higher FREL scores (71 vs. 57, P < .001) and lower FKGL scores (5.6 vs. 7.6, P < .001), compared to clinician-generated discharge instructions. The use of electronically available templated discharge instructions was associated with better readability (a higher FREL score and a lower FKGL score) than the use of clinician-generated discharge instructions. The main reason for clinicians to create discharge instructions was the lack of available templates for the patient's specific discharge diagnosis. Use of electronically available templated discharge instructions may be a viable option to improve the readability of written material provided to patients at discharge, although the library of available templates requires expansion. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. View-Invariant Gait Recognition Through Genetic Template Segmentation

    NASA Astrophysics Data System (ADS)

    Isaac, Ebenezer R. H. P.; Elias, Susan; Rajagopalan, Srinivasan; Easwarakumar, K. S.

    2017-08-01

    Template-based model-free approach provides by far the most successful solution to the gait recognition problem in literature. Recent work discusses how isolating the head and leg portion of the template increase the performance of a gait recognition system making it robust against covariates like clothing and carrying conditions. However, most involve a manual definition of the boundaries. The method we propose, the genetic template segmentation (GTS), employs the genetic algorithm to automate the boundary selection process. This method was tested on the GEI, GEnI and AEI templates. GEI seems to exhibit the best result when segmented with our approach. Experimental results depict that our approach significantly outperforms the existing implementations of view-invariant gait recognition.

  17. Superfund Removal Guidance for Preparing Action Memoranda

    EPA Pesticide Factsheets

    Dated September 2009, this updates and replaces previous documents. An Action Memo (AM) should substantiate need for removal action based upon criteria in the National Oil and Hazardous Substances Pollution Contingency Plan (NCP). Includes AM template.

  18. Emergency department documentation templates: variability in template selection and association with physical examination and test ordering in dizziness presentations.

    PubMed

    Kerber, Kevin A; Hofer, Timothy P; Meurer, William J; Fendrick, A Mark; Morgenstern, Lewis B

    2011-03-24

    Clinical documentation systems, such as templates, have been associated with process utilization. The T-System emergency department (ED) templates are widely used but lacking are analyses of the templates association with processes. This system is also unique because of the many different template options available, and thus the selection of the template may also be important. We aimed to describe the selection of templates in ED dizziness presentations and to investigate the association between items on templates and process utilization. Dizziness visits were captured from a population-based study of EDs that use documentation templates. Two relevant process outcomes were assessed: head computerized tomography (CT) scan and nystagmus examination. Multivariable logistic regression was used to estimate the probability of each outcome for patients who did or did not receive a relevant-item template. Propensity scores were also used to adjust for selection effects. The final cohort was 1,485 visits. Thirty-one different templates were used. Use of a template with a head CT item was associated with an increase in the adjusted probability of head CT utilization from 12.2% (95% CI, 8.9%-16.6%) to 29.3% (95% CI, 26.0%-32.9%). The adjusted probability of documentation of a nystagmus assessment increased from 12.0% (95%CI, 8.8%-16.2%) when a nystagmus-item template was not used to 95.0% (95% CI, 92.8%-96.6%) when a nystagmus-item template was used. The associations remained significant after propensity score adjustments. Providers use many different templates in dizziness presentations. Important differences exist in the various templates and the template that is used likely impacts process utilization, even though selection may be arbitrary. The optimal design and selection of templates may offer a feasible and effective opportunity to improve care delivery.

  19. SU-F-T-231: Improving the Efficiency of a Radiotherapy Peer-Review System for Quality Assurance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hsu, S; Basavatia, A; Garg, M

    Purpose: To improve the efficiency of a radiotherapy peer-review system using a commercially available software application for plan quality evaluation and documentation. Methods: A commercial application, FullAccess (Radialogica LLC, Version 1.4.4), was implemented in a Citrix platform for peer-review process and patient documentation. This application can display images, isodose lines, and dose-volume histograms and create plan reports for peer-review process. Dose metrics in the report can also be benchmarked for plan quality evaluation. Site-specific templates were generated based on departmental treatment planning policies and procedures for each disease site, which generally follow RTOG protocols as well as published prospective clinicalmore » trial data, including both conventional fractionation and hypo-fractionation schema. Once a plan is ready for review, the planner exports the plan to FullAccess, applies the site-specific template, and presents the report for plan review. The plan is still reviewed in the treatment planning system, as that is the legal record. Upon physician’s approval of a plan, the plan is packaged for peer review with the plan report and dose metrics are saved to the database. Results: The reports show dose metrics of PTVs and critical organs for the plans and also indicate whether or not the metrics are within tolerance. Graphical results with green, yellow, and red lights are displayed of whether planning objectives have been met. In addition, benchmarking statistics are collected to see where the current plan falls compared to all historical plans on each metric. All physicians in peer review can easily verify constraints by these reports. Conclusion: We have demonstrated the improvement in a radiotherapy peer-review system, which allows physicians to easily verify planning constraints for different disease sites and fractionation schema, allows for standardization in the clinic to ensure that departmental policies are maintained, and builds a comprehensive database for potential clinical outcome evaluation.« less

  20. Exploring the usefulness of comprehensive care plans for children with medical complexity (CMC): a qualitative study.

    PubMed

    Adams, Sherri; Cohen, Eyal; Mahant, Sanjay; Friedman, Jeremy N; Macculloch, Radha; Nicholas, David B

    2013-01-19

    The Medical Home model recommends that Children with Special Health Care Needs (CSHCN) receive a medical care plan, outlining the child's major medical issues and care needs to assist with care coordination. While care plans are a primary component of effective care coordination, the creation and maintenance of care plans is time, labor, and cost intensive, and the desired content of the care plan has not been studied. The purpose of this qualitative study was to understand the usefulness and desired content of comprehensive care plans by exploring the perceptions of parents and health care providers (HCPs) of children with medical complexity (CMC). This qualitative study utilized in-depth semi-structured interviews and focus groups. HCPs (n = 15) and parents (n = 15) of CMC who had all used a comprehensive care plan were recruited from a tertiary pediatric academic health sciences center. Themes were identified through grounded theory analysis of interview and focus group data. A multi-dimensional model of perceived care plan usefulness emerged. The model highlights three integral aspects of the care plan: care plan characteristics, activating factors and perceived outcomes of using a care plan. Care plans were perceived as a useful tool that centralized and focused the care of the child. Care plans were reported to flatten the hierarchical relationship between HCPs and parents, resulting in enhanced reciprocal information exchange and strengthened relationships. Participants expressed that a standardized template that is family-centered and includes content relevant to both the medical and social needs of the child is beneficial when integrated into overall care planning and delivery for CMC. Care plans are perceived to be a useful tool to both health care providers and parents of CMC. These findings inform the utility and development of a comprehensive care plan template as well as a model of how and when to best utilize care plans within family-centered models of care.

  1. Novel techniques for the synthesis of three-way catalytic converter support materials

    NASA Astrophysics Data System (ADS)

    Anyaba, Prince Nwabueze

    Current automobiles use catalytic converters, consisting of noble metals on an oxide support, to convert noxious engine exhaust pollutants into less harmful species. The development of mesoporous oxide supports with optimal pore geometries could enable these devises to decrease in size and weight and significantly reduce the metal loadings required to achieve optimal performance. Thus, in this work, I investigated a wide range of techniques for the synthesis of mesoporous oxides to determine if they could be adapted to ceria-zirconia-yttria mixed oxide (CZY) systems, which are the industry standard for the optimal oxide support for catalytic converter applications. Additionally, I compared and critically evaluated the catalytic performance of the CZY mixed oxides, which were synthesized from the various templating techniques. The catalytic performance test was broken up into two: catalyst activity test which was determined based on the light-off temperatures at which 50% conversion of the reacting species have been converted; and resistance to surface area loss under accelerated aging at heating rate of 20°C/min form 700 to 1000°C, with the final temperature being held fixed for 4 h. To date, the most cost effective methods for preparing mesoporous materials are via techniques that employ templates or structure directing agents. These templates can be divided into two groups: endo-templates (i.e., soft templates, such as surfactants, dendrimers, and block copolymers) and exo-templates (i.e., hard templates, such as porous carbons and resins). The soft templating techniques generally involve both sol-gel and templating methods, while the hard templates required no sol-gel chemistry to achieve the desired templating effect. The precursors for ceria, zirconia, and yttria used were cerium (III) nitrate hexahydrate, zirconyl nitrate, and yttrium nitrate hexahydrate, respectively. The mesoporous CZY materials that were synthesized had surface area values that were between 40 and 120 m2/g and pore diameters that range from 2.2 to 9.0 nm after calcination in air from ambient temperature to 600°C at heating rates varied from 1 to 20°C/min, with the final temperature being maintained for 4 h. The novel CZY oxides that were prepared from the different templating techniques were characterized using nitrogen physisorption to determine the Brunauer--Emmett--Teller (BET) surface area and the Barrett--Joyner--Halenda (BJH) pore size distribution. Samples that showed some promise were further examined by transmission electron microscopy (TEM) to study the morphology of the structure; scanning electron microscopy (SEM) to study the bulk surface structure; thermogravimetric analysis (TGA) and differential scanning calorimetry (DSC) to determine physical and chemical changes occurring during calcination; elemental analysis to determine composition; powder X-ray diffraction (PXD) to determine the existence of crystalline structure; and small angle X-ray diffraction (SAXD) to determine the occurrence of mesoscale ordering of repeating units. Finally, selected samples underwent catalytic testing under simulated exhaust conditions. The results of the tests showed that CZY materials synthesized using sol-gel methods with the Pluronic P123 soft template were the most active (i.e., had the lowest light off temperature), while CZY material with least loss of surface area after accelerated aging from 700 to 1000°C was the polymeric resin templated CZY materials.

  2. Technician Dave Brown installs a drilling template during construction of the all-composite left win

    NASA Technical Reports Server (NTRS)

    2002-01-01

    Technician Dave Brown installs a drilling template during construction of the all-composite left wing of NASA's Altair aircraft at General Atomics Aeronautical Systems, Inc., (GA-ASI) facility at Adelanto, Calif. General Atomics Aeronautical Systems, Inc., is developing the Altair version of its Predator B unmanned reconnaissance aircraft under NASA's Environmental Research Aircraft and Sensor Technology (ERAST) project. NASA plans to use the Altair as a technology demonstrator to validate a variety of command and control technologies for UAVs, as well as demonstrate the capability to perform a variety of Earth science missions. The Altair is designed to carry an 700-lb. payload of scientific instruments and imaging equipment for as long as 32 hours at up to 52,000 feet altitude. Eleven-foot extensions have been added to each wing, giving the Altair an overall wingspan of 86 feet with an aspect ratio of 23. It is powered by a 700-hp. rear-mounted TPE-331-10 turboprop engine, driving a three-blade propeller. Altair is scheduled to begin flight tests in the fourth quarter of 2002, and be acquired by NASA following successful completion of basic airworthiness tests in early 2003 for evaluation of over-the-horizon control, detect, see and avoid and other technologies required to allow UAVs to operate safely with other aircraft in the national airspace.

  3. Pigment tests evaluated by a model of chromatic discrimination.

    PubMed

    Smith, V C; Pokorny, J; Yeh, T

    1993-08-01

    Clinical color-vision tests are evaluated within the framework of a model of chromatic discrimination in terms of cone excitation. The motivation for this study was to derive a method for evaluation of test design, test sensitivity, and observer performance. The discrimination model is based on the assumption that chromatic discrimination is mediated in two independent channels, one for short-wavelength cones and one for long- and middle-wavelength cones. Luminance-dependent templates are derived for each channel, and they describe chromatic-discrimination behavior of the young color-normal observer. The templates incorporate receptor- and opponent-level gain controls. We show how the chromaticities of clinical tests can be calculated in cone-excitation units and how discrimination behavior on the tests can be plotted on the templates. The tests include the Farnsworth-Munsell 100-hue, the Farnsworth Panel D-15, the Farnsworth Panel D-15 desaturated, the American Optical Hardy-Rand-Rittler, the Farnsworth F2 plate, the Standard Pseudoisochromatic Plates, Part II, the Ishihara, and the Minimalist tests. Clinical-test data collected on young color-normal observers at different illumination levels show the validity of the techniques.

  4. Development of a scalable mental healthcare plan for a rural district in Ethiopia

    PubMed Central

    Fekadu, Abebaw; Hanlon, Charlotte; Medhin, Girmay; Alem, Atalay; Selamu, Medhin; Giorgis, Tedla W.; Shibre, Teshome; Teferra, Solomon; Tegegn, Teketel; Breuer, Erica; Patel, Vikram; Tomlinson, Mark; Thornicroft, Graham; Prince, Martin; Lund, Crick

    2016-01-01

    Background Developing evidence for the implementation and scaling up of mental healthcare in low- and middle-income countries (LMIC) like Ethiopia is an urgent priority. Aims To outline a mental healthcare plan (MHCP), as a scalable template for the implementation of mental healthcare in rural Ethiopia. Method A mixed methods approach was used to develop the MHCP for the three levels of the district health system (community, health facility and healthcare organisation). Results The community packages were community case detection, community reintegration and community inclusion. The facility packages included capacity building, decision support and staff well-being. Organisational packages were programme management, supervision and sustainability. Conclusions The MHCP focused on improving demand and access at the community level, inclusive care at the facility level and sustainability at the organisation level. The MHCP represented an essential framework for the provision of integrated care and may be a useful template for similar LMIC. PMID:26447174

  5. 16 CFR Figure 3 to Part 1213 - Motion of Test Template Arrested by Simultaneous Contact With Both Sides of “A” Section and...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 16 Commercial Practices 2 2014-01-01 2014-01-01 false Motion of Test Template Arrested by Simultaneous Contact With Both Sides of âAâ Section and Boundaries of Opening 3 Figure 3 to Part 1213 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS SAFETY...

  6. 16 CFR Figure 3 to Part 1213 - Motion of Test Template Arrested by Simultaneous Contact With Both Sides of “A” Section and...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Motion of Test Template Arrested by Simultaneous Contact With Both Sides of âAâ Section and Boundaries of Opening 3 Figure 3 to Part 1213 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS SAFETY...

  7. 16 CFR Figure 3 to Part 1213 - Motion of Test Template Arrested by Simultaneous Contact With Both Sides of “A” Section and...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 2 2012-01-01 2012-01-01 false Motion of Test Template Arrested by Simultaneous Contact With Both Sides of âAâ Section and Boundaries of Opening 3 Figure 3 to Part 1213 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS SAFETY...

  8. 16 CFR Figure 3 to Part 1213 - Motion of Test Template Arrested by Simultaneous Contact With Both Sides of “A” Section and...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 16 Commercial Practices 2 2013-01-01 2013-01-01 false Motion of Test Template Arrested by Simultaneous Contact With Both Sides of âAâ Section and Boundaries of Opening 3 Figure 3 to Part 1213 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS SAFETY...

  9. 16 CFR Figure 3 to Part 1213 - Motion of Test Template Arrested by Simultaneous Contact With Both Sides of “A” Section and...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Motion of Test Template Arrested by Simultaneous Contact With Both Sides of âAâ Section and Boundaries of Opening 3 Figure 3 to Part 1213 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS SAFETY...

  10. Learning templates for artistic portrait lighting analysis.

    PubMed

    Chen, Xiaowu; Jin, Xin; Wu, Hongyu; Zhao, Qinping

    2015-02-01

    Lighting is a key factor in creating impressive artistic portraits. In this paper, we propose to analyze portrait lighting by learning templates of lighting styles. Inspired by the experience of artists, we first define several novel features that describe the local contrasts in various face regions. The most informative features are then selected with a stepwise feature pursuit algorithm to derive the templates of various lighting styles. After that, the matching scores that measure the similarity between a testing portrait and those templates are calculated for lighting style classification. Furthermore, we train a regression model by the subjective scores and the feature responses of a template to predict the score of a portrait lighting quality. Based on the templates, a novel face illumination descriptor is defined to measure the difference between two portrait lightings. Experimental results show that the learned templates can well describe the lighting styles, whereas the proposed approach can assess the lighting quality of artistic portraits as human being does.

  11. Inhibition of RNA-Dependent DNA Polymerase of Avian Myeloblastosis Virus by Pyran Copolymer

    PubMed Central

    Papas, Takis S.; Pry, Thomas W.; Chirigos, Michael A.

    1974-01-01

    Pyran copolymer, a known immunostimulator, was found to be a potent inhibitor of purified DNA polymerase (deoxynucleosidetriphosphate: DNA deoxynucleotidyltransferase; EC 2.7.7.7) isolated from avian myeloblastosis virus. Unlike other inhibitors, pyran showed unique features of inhibition. It interacts with the polymerase at a region other than the template site. The inhibitory effect was overcome only by excess enzyme and not affected by excess template. The degree of inhibition was not template specific for the templates tested: 70S RNA from avian myeloblastosis virus, synthetic hybrid poly(rA)·oligo(dT)10, synthetic copolymer poly(dA-dT), and activated calf-thymus DNA. The observed rate of inhibition by pyran was shown to vary with the different polymerases tested. Inhibition was shown with all oncornaviral polymerases and, to a lesser extent, with mammalian polymerases. However, two of the three bacterial polymerases, by contrast, showed a marked activation. PMID:4131275

  12. Titanium template for scaphoid reconstruction.

    PubMed

    Haefeli, M; Schaefer, D J; Schumacher, R; Müller-Gerbl, M; Honigmann, P

    2015-06-01

    Reconstruction of a non-united scaphoid with a humpback deformity involves resection of the non-union followed by bone grafting and fixation of the fragments. Intraoperative control of the reconstruction is difficult owing to the complex three-dimensional shape of the scaphoid and the other carpal bones overlying the scaphoid on lateral radiographs. We developed a titanium template that fits exactly to the surfaces of the proximal and distal scaphoid poles to define their position relative to each other after resection of the non-union. The templates were designed on three-dimensional computed tomography reconstructions and manufactured using selective laser melting technology. Ten conserved human wrists were used to simulate the reconstruction. The achieved precision measured as the deviation of the surface of the reconstructed scaphoid from its virtual counterpart was good in five cases (maximal difference 1.5 mm), moderate in one case (maximal difference 3 mm) and inadequate in four cases (difference more than 3 mm). The main problems were attributed to the template design and can be avoided by improved pre-operative planning, as shown in a clinical case. © The Author(s) 2014.

  13. Guidelines for conducting pharmaceutical budget impact analyses for submission to public drug plans in Canada.

    PubMed

    Marshall, Deborah A; Douglas, Patrick R; Drummond, Michael F; Torrance, George W; Macleod, Stuart; Manti, Orlando; Cheruvu, Lokanadha; Corvari, Ron

    2008-01-01

    Until now, there has been no standardized method of performing and presenting budget impact analyses (BIAs) in Canada. Nevertheless, most drug plan managers have been requiring this economic data to inform drug reimbursement decisions. This paper describes the process used to develop the Canadian BIA Guidelines; describes the Guidelines themselves, including the model template; and compares this guidance with other guidance on BIAs. The intended audience includes those who develop, submit or use BIA models, and drug plan managers who evaluate BIA submissions. The Patented Medicine Prices Review Board (PMPRB) initiated the development of the Canadian BIA Guidelines on behalf of the National Prescription Drug Utilisation Information System (NPDUIS). The findings and recommendations from a needs assessment with respect to BIA submissions were reviewed to inform guideline development. In addition, a literature review was performed to identify existing BIA guidance. The detailed guidance was developed on this basis, and with the input of the NPDUIS Advisory Committee, including drug plan managers from multiple provinces in Canada and a representative from the Canadian Agency for Drugs and Technologies in Health. A Microsoft Excel-based interactive model template was designed to support BIA model development. Input regarding the guidelines and model template was sought from each NPDUIS Advisory Committee member to ensure compatibility with existing drug plan needs. Decisions were made by consensus through multiple rounds of review and discussion. Finally, BIA guidance in Canadian provinces and other countries were compared on the basis of multiple criteria. The BIA guidelines consist of three major sections: Analytic Framework, Inputs and Data Sources, and Reporting Format. The Analytic Framework section contains a discussion of nine general issues surrounding BIAs (model design, analytic perspective, time horizon, target population, costing, scenarios to be compared, the characterisation of uncertainty, discounting, and validation methods). The Inputs and Data Sources section addresses methods for market size estimation, comparator selection, scenario forecasting and drug price estimation. The Reporting Format section describes methods for BIA reporting. The new Canadian BIA Guidelines represent a significant departure from the limited guidance that was previously available from some of the provinces, because they include specific details of the methods of performing BIAs. The Canadian BIA Guidelines differ from the Principles of Good Research Practice for BIAs developed by the International Society for Pharmacoeconomic and Outcomes Research (ISPOR), which provide more general guidance. The Canadian BIA Guidelines and template build upon existing guidance to address the specific requirements of each of the participating drug plans in Canada. Both have been endorsed by the NPDUIS Steering Committee and the PMPRB for the standardization of BIA submissions.

  14. Do knowledge translation (KT) plans help to structure KT practices?

    PubMed

    Tchameni Ngamo, Salomon; Souffez, Karine; Lord, Catherine; Dagenais, Christian

    2016-06-17

    A knowledge translation (KT) planning template is a roadmap laying out the core elements to be considered when structuring the implementation of KT activities by researchers and practitioners. Since 2010, the Institut national de santé publique du Québec (INSPQ; Québec Public Health Institute) has provided tools and guidance to in-house project teams to help them develop KT plans. This study sought to identify the dimensions included in those plans and which ones were integrated and how. The results will be of interest to funding agencies and scientific organizations that provide frameworks for KT planning. The operationalization of KT planning dimensions was assessed in a mixed methods case study of 14 projects developed at the INSPQ between 2010 and 2013. All plans were assessed (rated) using an analytical tool developed for this study and data from interviews with the planning coordinators. The analytical tool and interview guide were based on eight core KT dimensions identified in the literature. Analysis of the plans and interviews revealed that the dimensions best integrated into the KT plans were 'analysis of the context (barriers and facilitators) and of users' needs', 'knowledge to be translated', 'KT partners', 'KT strategies' and, to a lesser extent, 'overall KT approach'. The least well integrated dimensions were 'knowledge about knowledge users', 'KT process evaluation' and 'resources'. While the planning coordinators asserted that a plan did not need to include all the dimensions to ensure its quality and success, nevertheless the dimensions that received less attention might have been better incorporated if they had been supported with more instruments related to those dimensions and sustained methodological guidance. Overall, KT planning templates appear to be an appreciated mechanism for supporting KT reflexive practices. Based on this study and our experience, we recommend using KT plans cautiously when assessing project efficacy and funding.

  15. MO-F-CAMPUS-T-05: SQL Database Queries to Determine Treatment Planning Resource Usage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fox, C; Gladstone, D

    2015-06-15

    Purpose: A radiation oncology clinic’s treatment capacity is traditionally thought to be limited by the number of machines in the clinic. As the number of fractions per course decrease and the number of adaptive plans increase, the question of how many treatment plans a clinic can plan becomes increasingly important. This work seeks to lay the ground work for assessing treatment planning resource usage. Methods: Care path templates were created using the Aria 11 care path interface. Care path tasks included key steps in the treatment planning process from the completion of CT simulation through the first radiation treatment. SQLmore » Server Management Studio was used to run SQL queries to extract task completion time stamps along with care path template information and diagnosis codes from the Aria database. 6 months of planning cycles were evaluated. Elapsed time was evaluated in terms of work hours within Monday – Friday, 7am to 5pm. Results: For the 195 validated treatment planning cycles, the average time for planning and MD review was 22.8 hours. Of those cases 33 were categorized as urgent. The average planning time for urgent plans was 5 hours. A strong correlation between diagnosis code and range of elapsed planning time was as well as between elapsed time and select diagnosis codes was observed. It was also observed that tasks were more likely to be completed on the date due than the time that they were due. Follow-up confirmed that most users did not look at the due time. Conclusion: Evaluation of elapsed planning time and other tasks suggest that care paths should be adjusted to allow for different contouring and planning times for certain diagnosis codes and urgent cases. Additional clinic training around task due times vs dates or a structuring of care paths around due dates is also needed.« less

  16. Development and evaluation of an end‐to‐end test for head and neck IMRT with a novel multiple‐dosimetric modality phantom

    PubMed Central

    Zakjevskii, Viatcheslav V.; Knill, Cory S.; Rakowski, Joseph. T.

    2016-01-01

    A comprehensive end‐to‐end test for head and neck IMRT treatments was developed using a custom phantom designed to utilize multiple dosimetry devices. Initial end‐to‐end test and custom H&N phantom were designed to yield maximum information in anatomical regions significant to H&N plans with respect to: (i) geometric accuracy, (ii) dosimetric accuracy, and (iii) treatment reproducibility. The phantom was designed in collaboration with Integrated Medical Technologies. The phantom was imaged on a CT simulator and the CT was reconstructed with 1 mm slice thickness and imported into Varian's Eclipse treatment planning system. OARs and the PTV were contoured with the aid of Smart Segmentation. A clinical template was used to create an eight‐field IMRT plan and dose was calculated with heterogeneity correction on. Plans were delivered with a TrueBeam equipped with a high definition MLC. Preliminary end‐to‐end results were measured using film, ion chambers, and optically stimulated luminescent dosimeters (OSLDs). Ion chamber dose measurements were compared to the treatment planning system. Films were analyzed with FilmQA Pro using composite gamma index. OSLDs were read with a MicroStar reader using a custom calibration curve. Final phantom design incorporated two axial and one coronal film planes with 18 OSLD locations adjacent to those planes as well as four locations for IMRT ionization chambers below inferior film plane. The end‐to‐end test was consistently reproducible, resulting in average gamma pass rate greater than 99% using 3%/3 mm analysis criteria, and average OSLD and ion chamber measurements within 1% of planned dose. After initial calibration of OSLD and film systems, the end‐to‐end test provides next‐day results, allowing for integration in routine clinical QA. Preliminary trials have demonstrated that our end‐to‐end is a reproducible QA tool that enables the ongoing evaluation of dosimetric and geometric accuracy of clinical head and neck treatments. PACS number(s): 87.55.Qr PMID:27074453

  17. 48 CFR 302.7100 - HHS standard templates and formats.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...). Acquisition Strategy 307.104-70. Annual Acquisition Plan 307.104(a)(5). Competition Advocate Report 306.502(b... Request for Information 315.201(e)(4). FedBizOpps Small Business Sources Sought Notice 319.202-2(a)(3...

  18. Berkeley Lab - Materials Sciences Division

    Science.gov Websites

    MSD Support Human Resources Facilities & Space Planning Procurement and Property Proposals & ; Finance Templates Travel One-Stop Acknowledging MSD Support Human Resources Facilities & Space Operations For information regarding Human Resources, procedures for acknowledging MSD support, division

  19. Plan recommendation for traffic sign management.

    DOT National Transportation Integrated Search

    2012-12-01

    This report template reflects the Guidelines for Preparing UDOT Research Reports, revised April 2012. It may be used for preparation of UDOT research reports. Include a brief summary of the report here in 200-250 words. The Federal Highway Admi...

  20. The Grid[Way] Job Template Manager, a tool for parameter sweeping

    NASA Astrophysics Data System (ADS)

    Lorca, Alejandro; Huedo, Eduardo; Llorente, Ignacio M.

    2011-04-01

    Parameter sweeping is a widely used algorithmic technique in computational science. It is specially suited for high-throughput computing since the jobs evaluating the parameter space are loosely coupled or independent. A tool that integrates the modeling of a parameter study with the control of jobs in a distributed architecture is presented. The main task is to facilitate the creation and deletion of job templates, which are the elements describing the jobs to be run. Extra functionality relies upon the GridWay Metascheduler, acting as the middleware layer for job submission and control. It supports interesting features like multi-dimensional sweeping space, wildcarding of parameters, functional evaluation of ranges, value-skipping and job template automatic indexation. The use of this tool increases the reliability of the parameter sweep study thanks to the systematic bookkeeping of job templates and respective job statuses. Furthermore, it simplifies the porting of the target application to the grid reducing the required amount of time and effort. Program summaryProgram title: Grid[Way] Job Template Manager (version 1.0) Catalogue identifier: AEIE_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEIE_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Apache license 2.0 No. of lines in distributed program, including test data, etc.: 3545 No. of bytes in distributed program, including test data, etc.: 126 879 Distribution format: tar.gz Programming language: Perl 5.8.5 and above Computer: Any (tested on PC x86 and x86_64) Operating system: Unix, GNU/Linux (tested on Ubuntu 9.04, Scientific Linux 4.7, centOS 5.4), Mac OS X (tested on Snow Leopard 10.6) RAM: 10 MB Classification: 6.5 External routines: The GridWay Metascheduler [1]. Nature of problem: To parameterize and manage an application running on a grid or cluster. Solution method: Generation of job templates as a cross product of the input parameter sets. Also management of the job template files including the job submission to the grid, control and information retrieval. Restrictions: The parameter sweep is limited by disk space during generation of the job templates. The wild-carding of parameters cannot be done in decreasing order. Job submission, control and information is delegated to the GridWay Metascheduler. Running time: From half a second in the simplest operation to a few minutes for thousands of exponential sampling parameters.

  1. New membrane technologies: Nanotube membranes for biotechnological applications and polyaniline films for corrosion inhibition

    NASA Astrophysics Data System (ADS)

    Gasparac, Rahela

    Chapter 1 provides background information on the template synthesis of nanomaterials. A description of the types of membranes used for template synthesis is given. Different chemistries that have been used to prepare template-synthesized structures are provided. Template synthesis has been used to prepare some important nanostructures. Polycarbonate membranes were used to prepare gold nanotubes using electroless gold template method. SiO2 nano-test-tubes were made by dipping the alumina template membrane in the sol and heating. An introduction to conductive is presented here as well. Chapter 2 describes the transport of DNA molecules through nanopore membranes. We are interested in how pore diameter of the membrane affects rate and selectivity of DNA transport of different size and charge. Commercially available microporous polycarbonate membrane filters were used. DNA chains can be driven through the nanopore via the electrokinetic transport processes of electrophoresis and electroolsmotic flow, as well as by diffusion. To our knowledge, there have been no quantitative studies of the relative importance of the electrokinetic and diffusive components for DNA transport in a nanopore system. Chapter 3 describes a sol-gel template synthesis process that is used to produce silica nano-test-tubes within the pores of alumina templates. These silica nano-test-tubes are important because of the ease with which nearly any desired chemical or biochemical reagent can be covalently attached to their inside and outside surfaces. Inner and outer surfaces of the silica nano-test-tubes were functionalized using well-known silane chemistry. Green fluorescent silane was attached to the inner surfaces. The outer SiO 2 nano-test-tube surfaces were antibody functionalized using aldehyde methoxysilane linker. One of our key long-range objective is to develop nanotube technology for delivering biomolecules (e.g., DNA) to living cells. Chapter 4 focuses on the mechanism by which polyaniline (PANI) films passivate stainless steel surfaces in highly corrosive H2SO 4 solution. A variety of experimental methods including measurements of the open circuit potential, Auger depth profiling, and the scanning reference electrode technique (SRET) was used. These studies have shown that passivation is achieved because the oxidized and protically-doped emeraldine-salt form of PANI holds the potential of the underlying stainless steel electrode in the passive region. Because of this electrostatic mechanism of corrosion inhibition, the entire stainless steel surface does not have to be coated with PANI in order to achieve passivation.

  2. A fast template periodogram

    NASA Astrophysics Data System (ADS)

    Hoffman, John; VanderPlas, Jake; Hartman, Joel; Bakos, Gáspár

    2017-09-01

    This proceedings contribution presents a novel, non-linear extension to the Lomb-Scargle periodogram that allows periodograms to be generated for arbitrary signal shapes. Such periodograms are already known as "template periodograms" or "periodic matched filters," but current implementations are computationally inefficient. The "fast template periodogram" presented here improves existing techniques by a factor of ˜a few for small test cases (O(10) observations), and over three orders of magnitude for lightcurves containing O(104) observations. The fast template periodogram scales asymptotically as O(HNf log HNf + H4Nf), where H denotes the number of harmonics required to adequately approximate the template and Nf is the number of trial frequencies. Existing implementations scale as O(NobsNf), where Nobs is the number of observations in the lightcurve. An open source Python implementation is available on GitHub.

  3. Age-specific MRI brain and head templates for healthy adults from 20 through 89 years of age

    PubMed Central

    Fillmore, Paul T.; Phillips-Meek, Michelle C.; Richards, John E.

    2015-01-01

    This study created and tested a database of adult, age-specific MRI brain and head templates. The participants included healthy adults from 20 through 89 years of age. The templates were done in five-year, 10-year, and multi-year intervals from 20 through 89 years, and consist of average T1W for the head and brain, and segmenting priors for gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF). It was found that age-appropriate templates provided less biased tissue classification estimates than age-inappropriate reference data and reference data based on young adult templates. This database is available for use by other investigators and clinicians for their MRI studies, as well as other types of neuroimaging and electrophysiological research.1 PMID:25904864

  4. Multimodal biometric approach for cancelable face template generation

    NASA Astrophysics Data System (ADS)

    Paul, Padma Polash; Gavrilova, Marina

    2012-06-01

    Due to the rapid growth of biometric technology, template protection becomes crucial to secure integrity of the biometric security system and prevent unauthorized access. Cancelable biometrics is emerging as one of the best solutions to secure the biometric identification and verification system. We present a novel technique for robust cancelable template generation algorithm that takes advantage of the multimodal biometric using feature level fusion. Feature level fusion of different facial features is applied to generate the cancelable template. A proposed algorithm based on the multi-fold random projection and fuzzy communication scheme is used for this purpose. In cancelable template generation, one of the main difficulties is keeping interclass variance of the feature. We have found that interclass variations of the features that are lost during multi fold random projection can be recovered using fusion of different feature subsets and projecting in a new feature domain. Applying the multimodal technique in feature level, we enhance the interclass variability hence improving the performance of the system. We have tested the system for classifier fusion for different feature subset and different cancelable template fusion. Experiments have shown that cancelable template improves the performance of the biometric system compared with the original template.

  5. Numerical Control Device for Preparation Nano-Carbon Granule Coating Superhydrophobic Template and Its Application

    NASA Astrophysics Data System (ADS)

    Shang, G. R.; Li, Y.

    2017-12-01

    It is one of the ways for changing surface property by fabricating superhydrophibic coating with the help of template that is made of depositing nano-carbon particles of fuel flame on substrate such as pure copper or aluminium alloy. In the process of making template, it is difficult to keep the deposition layer uniformed. In this work, the problem was solved by manufacturing a set of numerical control equipment. It has been proved by application test that the deposition layer was uniformed by means of this facility. The contact angle is more than 150°. A new way has been developed for making superhydrohibic template.

  6. Generating Test Templates via Automated Theorem Proving

    NASA Technical Reports Server (NTRS)

    Kancherla, Mani Prasad

    1997-01-01

    Testing can be used during the software development process to maintain fidelity between evolving specifications, program designs, and code implementations. We use a form of specification-based testing that employs the use of an automated theorem prover to generate test templates. A similar approach was developed using a model checker on state-intensive systems. This method applies to systems with functional rather than state-based behaviors. This approach allows for the use of incomplete specifications to aid in generation of tests for potential failure cases. We illustrate the technique on the cannonical triangle testing problem and discuss its use on analysis of a spacecraft scheduling system.

  7. Automated high-dose rate brachytherapy treatment planning for a single-channel vaginal cylinder applicator

    NASA Astrophysics Data System (ADS)

    Zhou, Yuhong; Klages, Peter; Tan, Jun; Chi, Yujie; Stojadinovic, Strahinja; Yang, Ming; Hrycushko, Brian; Medin, Paul; Pompos, Arnold; Jiang, Steve; Albuquerque, Kevin; Jia, Xun

    2017-06-01

    High dose rate (HDR) brachytherapy treatment planning is conventionally performed manually and/or with aids of preplanned templates. In general, the standard of care would be elevated by conducting an automated process to improve treatment planning efficiency, eliminate human error, and reduce plan quality variations. Thus, our group is developing AutoBrachy, an automated HDR brachytherapy planning suite of modules used to augment a clinical treatment planning system. This paper describes our proof-of-concept module for vaginal cylinder HDR planning that has been fully developed. After a patient CT scan is acquired, the cylinder applicator is automatically segmented using image-processing techniques. The target CTV is generated based on physician-specified treatment depth and length. Locations of the dose calculation point, apex point and vaginal surface point, as well as the central applicator channel coordinates, and the corresponding dwell positions are determined according to their geometric relationship with the applicator and written to a structure file. Dwell times are computed through iterative quadratic optimization techniques. The planning information is then transferred to the treatment planning system through a DICOM-RT interface. The entire process was tested for nine patients. The AutoBrachy cylindrical applicator module was able to generate treatment plans for these cases with clinical grade quality. Computation times varied between 1 and 3 min on an Intel Xeon CPU E3-1226 v3 processor. All geometric components in the automated treatment plans were generated accurately. The applicator channel tip positions agreed with the manually identified positions with submillimeter deviations and the channel orientations between the plans agreed within less than 1 degree. The automatically generated plans obtained clinically acceptable quality.

  8. CAD/CAM guided surgery in implant dentistry. A review of software packages and step-by-step protocols for planning surgical guides.

    PubMed

    Scherer, Michael D; Kattadiyil, Mathew T; Parciak, Ewa; Puri, Shweta

    2014-01-01

    Three-dimensional radiographic imaging for dental implant treatment planning is gaining widespread interest and popularity. However, application of the data from 30 imaging can be a complex and daunting process initially. The purpose of this article is to describe features of three software packages and the respective computerized guided surgical templates (GST) fabricated from them. A step-by-step method of interpreting and ordering a GST to simplify the process of the surgical planning and implant placement is discussed.

  9. SU-F-T-20: Novel Catheter Lumen Recognition Algorithm for Rapid Digitization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dise, J; McDonald, D; Ashenafi, M

    Purpose: Manual catheter recognition remains a time-consuming aspect of high-dose-rate brachytherapy (HDR) treatment planning. In this work, a novel catheter lumen recognition algorithm was created for accurate and rapid digitization. Methods: MatLab v8.5 was used to create the catheter recognition algorithm. Initially, the algorithm searches the patient CT dataset using an intensity based k-means filter designed to locate catheters. Once the catheters have been located, seed points are manually selected to initialize digitization of each catheter. From each seed point, the algorithm searches locally in order to automatically digitize the remaining catheter. This digitization is accomplished by finding pixels withmore » similar image curvature and divergence parameters compared to the seed pixel. Newly digitized pixels are treated as new seed positions, and hessian image analysis is used to direct the algorithm toward neighboring catheter pixels, and to make the algorithm insensitive to adjacent catheters that are unresolvable on CT, air pockets, and high Z artifacts. The algorithm was tested using 11 HDR treatment plans, including the Syed template, tandem and ovoid applicator, and multi-catheter lung brachytherapy. Digitization error was calculated by comparing manually determined catheter positions to those determined by the algorithm. Results: he digitization error was 0.23 mm ± 0.14 mm axially and 0.62 mm ± 0.13 mm longitudinally at the tip. The time of digitization, following initial seed placement was less than 1 second per catheter. The maximum total time required to digitize all tested applicators was 4 minutes (Syed template with 15 needles). Conclusion: This algorithm successfully digitizes HDR catheters for a variety of applicators with or without CT markers. The minimal axial error demonstrates the accuracy of the algorithm, and its insensitivity to image artifacts and challenging catheter positioning. Future work to automatically place initial seed positions would improve the algorithm speed.« less

  10. Template occluded SBA-15: An effective dissolution enhancer for poorly water-soluble drug

    NASA Astrophysics Data System (ADS)

    Tingming, Fu; Liwei, Guo; Kang, Le; Tianyao, Wang; Jin, Lu

    2010-09-01

    The aim of the present work was to improve the dissolution rate of piroxicam by inclusion into template occluded SBA-15. Our strategy involves directly introducing piroxicam into as-prepared SBA-15 occluded with P123 (EO 20PO 70EO 20) by self assembling method in acetonitrile/methylene chloride mixture solution. Ultraviolet spectrometry experiment and thermogravimetric analysis-differential scanning calorimetry (TG-DSC) profiles show that the piroxicam and P123 contents in the inclusion compound are 12 wt% and 28 wt%, respectively. X-ray powder diffraction and DSC analysis reveal that the included piroxicam is arranged in amorphous form. N 2 adsorption-desorption experiment indicates that the piroxicam has been introduced to the mesopores instead of precipitating at the outside of the silica material. The inclusion compound was submitted to in vitro dissolution tests, the results show that the piroxicam dissolve from template occluded inclusion compound more rapidly, than these from the piroxicam crystalline and template removed samples in all tested conditions. Thus a facile method to improve the dissolution rate of poorly water-soluble drug was established, and this discovery opens a new avenue for the utilization of templates used for the synthesis of mesoporous materials.

  11. Model Building.

    ERIC Educational Resources Information Center

    Day, C. William; Parsley, James

    1996-01-01

    Describes how school boards and administrators can use a facility-planning symposium, which brings together educators, students, parents, business leaders, and others, to establish an educational program and to design a template representative of the community. Examines ways to construct a shared vision and looks at design issues. (RJM)

  12. A public health hazard mitigation planning process.

    PubMed

    Griffith, Jennifer M; Kay Carpender, S; Crouch, Jill Artzberger; Quiram, Barbara J

    2014-01-01

    The Texas A&M Health Science Center School of Rural Public Health, a member of the Training and Education Collaborative System Preparedness and Emergency Response Learning Center (TECS-PERLC), has long-standing partnerships with 2 Health Service Regions (Regions) in Texas. TECS-PERLC was contracted by these Regions to address 2 challenges identified in meeting requirements outlined by the Risk-Based Funding Project. First, within Metropolitan Statistical Areas, there is not a formal authoritative structure. Second, preexisting tools and processes did not adequately satisfy requirements to assess public health, medical, and mental health needs and link mitigation strategies to the Public Health Preparedness Capabilities, which provide guidance to prepare for, respond to, and recover from public health incidents. TECS-PERLC, with its partners, developed a framework to interpret and apply results from the Texas Public Health Risk Assessment Tool (TxPHRAT). The 3-phase community engagement-based TxPHRAT Mitigation Planning Process (Mitigation Planning Process) and associated tools facilitated the development of mitigation plans. Tools included (1) profiles interpreting TxPHRAT results and identifying, ranking, and prioritizing hazards and capability gaps; (2) a catalog of intervention strategies and activities linked to hazards and capabilities; and (3) a template to plan, evaluate, and report mitigation planning efforts. The Mitigation Planning Process provided a framework for Regions to successfully address all funding requirements. TECS-PERLC developed more than 60 profiles, cataloged and linked 195 intervention strategies, and developed a template resulting in 20 submitted mitigation plans. A public health-focused, community engagement-based mitigation planning process was developed by TECS-PERLC and successfully implemented by the Regions. The outcomes met all requirements and reinforce the effectiveness of academic practice partnerships and importance of community engagement in mitigation planning. Additional funding has been approved to expand the Mitigation Planning Process to all counties in Texas with local health departments.

  13. How to identify rectal sub-regions likely involved in rectal bleeding in prostate cancer radiotherapy

    NASA Astrophysics Data System (ADS)

    Dréan, G.; Acosta, O.; Ospina, J. D.; Voisin, C.; Rigaud, B.; Simon, A.; Haigron, P.; de Crevoisier, R.

    2013-11-01

    Nowadays, the de nition of patient-speci c constraints in prostate cancer radiotherapy planning are solely based on dose-volume histogram (DVH) parameters. Nevertheless those DVH models lack of spatial accuracy since they do not use the complete 3D information of the dose distribution. The goal of the study was to propose an automatic work ow to de ne patient-speci c rectal sub-regions (RSR) involved in rectal bleeding (RB) in case of prostate cancer radiotherapy. A multi-atlas database spanning the large rectal shape variability was built from a population of 116 individuals. Non-rigid registration followed by voxel-wise statistical analysis on those templates allowed nding RSR likely correlated with RB (from a learning cohort of 63 patients). To de ne patient-speci c RSR, weighted atlas-based segmentation with a vote was then applied to 30 test patients. Results show the potentiality of the method to be used for patient-speci c planning of intensity modulated radiotherapy (IMRT).

  14. Development of a femoral template for computer-assisted tunnel placement in anatomical double-bundle ACL reconstruction.

    PubMed

    Luites, J W H; Wymenga, A B; Blankevoort, L; Kooloos, J M G; Verdonschot, N

    2011-01-01

    Femoral graft placement is an important factor in the success of anterior cruciate ligament (ACL) reconstruction. In addition to improving the accuracy of femoral tunnel placement, Computer Assisted Surgery (CAS) can be used to determine the anatomic location. This is achieved by using a 3D femoral template which indicates the position of the anatomical ACL center based on endoscopically measurable landmarks. This study describes the development and application of this method. The template is generated through statistical shape analysis of the ACL insertion, with respect to the anteromedial (AM) and posterolateral (PL) bundles. The ligament insertion data, together with the osteocartilage edge on the lateral notch, were mapped onto a cylinder fitted to the intercondylar notch surface (n = 33). Anatomic variation, in terms of standard variation of the positions of the ligament centers in the template, was within 2.2 mm. The resulting template was programmed in a computer-assisted navigation system for ACL replacement and its accuracy and precision were determined on 31 femora. It was found that with the navigation system the AM and PL tunnels could be positioned with an accuracy of 2.5 mm relative to the anatomic insertion centers; the precision was 2.4 mm. This system consists of a template that can easily be implemented in 3D computer navigation software. Requiring no preoperative images and planning, the system provides adequate accuracy and precision to position the entrance of the femoral tunnels for anatomical single- or double-bundle ACL reconstruction.

  15. Postextraction computer-guided implant surgery in partially edentate patients with metal restorations: a case report.

    PubMed

    Pinto, A; Raffone, C

    2017-01-01

    The aim of the present study was to describe a postextraction, computer-guided protocol for implant-prosthetic rehabilitations in partially edentate patients with metal restorations. A 60-year-old man with a loose FDP (fixed dental prosthesis) in the first quadrant was selected for a postextraction computer guided implantology according with the 2-piece radiographic template protocol. A two components radiographic template was produced, with the teeth setup portion based on the wax-up. CBCT (cone beam computed tomography) scans of the patient, wearing the base portion of the radiographic template and of the assembled radiographic template alone, were accomplished. The CBCT volume were imported in a dedicated software (NobelClinician, Nobel-Biocare, Kloten, Switzerland) and a surgical template was produced from the digital planning. The surgery was performed with a flap approach, as a bone regeneration procedure was carried out. A delayed loading protocol was chosen to allow a healing free of masticatory stress. A mobile partial denture was delivered to the patient to grant function and social life until the delivery of the definitive FDP. The surgery was performed rapidly and free of obstacles. A good primary stability of the implants was achieved. The patient referred an acceptable postoperative pain and swelling. The 2-piece radiographic template protocol was evaluated as smooth, complication-free and suitable for patients who want to maintain their teeth until the day of implant surgery. A good command of the computer-guided software as well as a comprehensive learning curve in computer-guided implantology is necessary to obtain predictable results.

  16. Planning surgical reconstruction in Treacher-Collins syndrome using virtual simulation.

    PubMed

    Nikkhah, Dariush; Ponniah, Allan; Ruff, Cliff; Dunaway, David

    2013-11-01

    Treacher-Collins syndrome is a rare autosomal dominant condition of varying phenotypic expression. The surgical correction in this syndrome is difficult, and the approach varies between craniofacial departments worldwide. The authors aimed to design standardized tools for planning orbitozygomatic and mandibular reconstruction in Treacher-Collins syndrome using geometric morphometrics. The Great Ormond Street Hospital database was retrospectively identified for patients with Treacher-Collins syndrome. Thirteen children (aged 2 to 15 years) who had suitable preoperative three-dimensional computed tomographic head scans were included. Six Treacher-Collins syndrome three-dimensional computed tomographic head scans were quantitatively compared using a template of 96 anatomically defined landmarks to 26 age-matched normal dry skulls. Thin-plate spline videos illustrated the characteristic deformities of retromicrognathia and maxillary and orbitozygomatic hypoplasia in the Treacher-Collins syndrome population. Geometric morphometrics was used in the virtual reconstruction of the orbitozygomatic and mandibular region in Treacher-Collins syndrome patients. Intrarater and interrater reliability of the landmarks was acceptable and within a standard deviation of less than 1 mm on 97 percent and 100 percent of 10 repeated scans, respectively. Virtual normalization of the Treacher-Collins syndrome skull effectively describes characteristic skeletal deformities and provides a useful guide to surgical reconstruction. Size-matched stereolithographic templates derived from thin-plate spline warps can provide effective intraoperative templates for zygomatic and mandibular reconstruction in the Treacher-Collins syndrome patient. Diagnostic, V.

  17. A C++11 implementation of arbitrary-rank tensors for high-performance computing

    NASA Astrophysics Data System (ADS)

    Aragón, Alejandro M.

    2014-06-01

    This article discusses an efficient implementation of tensors of arbitrary rank by using some of the idioms introduced by the recently published C++ ISO Standard (C++11). With the aims at providing a basic building block for high-performance computing, a single Array class template is carefully crafted, from which vectors, matrices, and even higher-order tensors can be created. An expression template facility is also built around the array class template to provide convenient mathematical syntax. As a result, by using templates, an extra high-level layer is added to the C++ language when dealing with algebraic objects and their operations, without compromising performance. The implementation is tested running on both CPU and GPU.

  18. A C++11 implementation of arbitrary-rank tensors for high-performance computing

    NASA Astrophysics Data System (ADS)

    Aragón, Alejandro M.

    2014-11-01

    This article discusses an efficient implementation of tensors of arbitrary rank by using some of the idioms introduced by the recently published C++ ISO Standard (C++11). With the aims at providing a basic building block for high-performance computing, a single Array class template is carefully crafted, from which vectors, matrices, and even higher-order tensors can be created. An expression template facility is also built around the array class template to provide convenient mathematical syntax. As a result, by using templates, an extra high-level layer is added to the C++ language when dealing with algebraic objects and their operations, without compromising performance. The implementation is tested running on both CPU and GPU.

  19. Modulation of gene expression using electrospun scaffolds with templated architecture.

    PubMed

    Karchin, A; Wang, Y-N; Sanders, J E

    2012-06-01

    The fabrication of biomimetic scaffolds is a critical component to fulfill the promise of functional tissue-engineered materials. We describe herein a simple technique, based on printed circuit board manufacturing, to produce novel templates for electrospinning scaffolds for tissue-engineering applications. This technique facilitates fabrication of electrospun scaffolds with templated architecture, which we defined as a scaffold's bulk mechanical properties being driven by its fiber architecture. Electrospun scaffolds with templated architectures were characterized with regard to fiber alignment and mechanical properties. Fast Fourier transform analysis revealed a high degree of fiber alignment along the conducting traces of the templates. Mechanical testing showed that scaffolds demonstrated tunable mechanical properties as a function of templated architecture. Fibroblast-seeded scaffolds were subjected to a peak strain of 3 or 10% at 0.5 Hz for 1 h. Exposing seeded scaffolds to the low strain magnitude (3%) significantly increased collagen I gene expression compared to the high strain magnitude (10%) in a scaffold architecture-dependent manner. These experiments indicate that scaffolds with templated architectures can be produced, and modulation of gene expression is possible with templated architectures. This technology holds promise for the long-term goal of creating tissue-engineered replacements with the biomechanical and biochemical make-up of native tissues. Copyright © 2012 Wiley Periodicals, Inc.

  20. SU-D-210-07: The Dependence On Acoustic Velocity of Medium On the Needle Template and Electronic Grid Alignment in Ultrasound QA for Prostate Brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kapoor, P; Kapoor, R; Curran, B

    Purpose: To analyze the impact on acoustic velocity (AV) of two different media (water and milk) using the needle template/electronic grid alignment test. Water, easily available, makes a good material to test the alignment of the template and grid although water’s AV (1498 m/s at 25°C) is significantly different from tissue (1540 m/s). Milk, with an AV much closer (1548 m/s) to prostate tissue, may be a good substitute for water in ultrasound quality assurance testing. Methods: Tests were performed using a Hitachi ultrasound unit with a mechanical arrangement designed to position needles parallel to the transducer. In this work,more » two materials – distilled water and homogenized whole milk (AVs of 1498 and 1548 m/s at 25°C) were used in a phantom to test ultrasound needle/grid alignment. The images were obtained with both materials and analyzed for their placement accuracy. Results: The needle template/electronic grid alignment tests showed displacement errors between measured and calculated values. The measurements showed displacements of 2.3mm (water) and 0.4mm (milk), and 1.6mm (water) and 0.3mm (milk) at depths of 7cm and 5cm respectively from true needle positions. The calculated results showed a displacement of 2.36 mm (water); 0.435mm (milk), and 1.66mm (water) and 0.31mm (milk) at a depth of 7cm and 5cm respectively. The displacements in the X and Y directions were also calculated. At depths of 7cm and 5cm, the (ΔX,ΔY) displacements in water were (0.829mm, 2.21mm) and (0.273mm, 1.634mm) and for milk were (0.15mm, 0.44mm) and (0.05mm, 0.302mm) respectively. Conclusion: The measured and calculated values were in good agreement for all tests. They show that milk provides superior results when performing needle template and electronic grid alignment tests for ultrasound units used in prostate brachytherapy.« less

  1. X-Gliders: Exploring Flight Research with Experimental Gliders. Educational Brief.

    ERIC Educational Resources Information Center

    National Aeronautics and Space Administration, Washington, DC.

    This brief discusses X-gliders and flight research with experimental gliders. In this activity, designed for grades K-4, students will learn how to change the flight characteristics of a glider using scientific inquiry methods. Glider plans and a template are included. (MVL)

  2. Not single brain areas but a network is involved in language: Applications in presurgical planning.

    PubMed

    Alemi, Razieh; Batouli, Seyed Amir Hossein; Behzad, Ebrahim; Ebrahimpoor, Mitra; Oghabian, Mohammad Ali

    2018-02-01

    Language is an important human function, and is a determinant of the quality of life. In conditions such as brain lesions, disruption of the language function may occur, and lesion resection is a solution for that. Presurgical planning to determine the language-related brain areas would enhance the chances of language preservation after the operation; however, availability of a normative language template is essential. In this study, using data from 60 young individuals who were meticulously checked for mental and physical health, and using fMRI and robust imaging and data analysis methods, functional brain maps for the language production, perception and semantic were produced. The obtained templates showed that the language function should be considered as the product of the collaboration of a network of brain regions, instead of considering only few brain areas to be involved in that. This study has important clinical applications, and extends our knowledge on the neuroanatomy of the language function. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Computer-assisted surgery in the lower jaw: double surgical guide for immediately loaded implants in postextractive sites-technical notes and a case report.

    PubMed

    De Santis, Daniele; Canton, Luciano Claudio; Cucchi, Alessandro; Zanotti, Guglielmo; Pistoia, Enrico; Nocini, Pier Francesco

    2010-01-01

    Computer-assisted surgery is based on computerized tomography (CT) scan technology to plan the placement of dental implants and a computer-aided design/computer-aided manufacturing (CAD-CAM) technology to create a custom surgical template. It provides guidance for insertion implants after analysis of existing alveolar bone and planning of implant position, which can be immediately loaded, therefore achieving esthetic and functional results in a surgical stage. The absence of guidelines to treat dentulous areas is often due to a lack of computer-assisted surgery. The authors have attempted to use this surgical methodology to replace residual teeth with an immediate implantoprosthetic restoration. The aim of this case report is to show the possibility of treating a dentulous patient by applying a computer-assisted surgical protocol associated with the use of a double surgical template: one before extraction and a second one after extraction of selected teeth.

  4. [Development of a portfolio for competency-based assessment in a clinical clerkship curriculum].

    PubMed

    Roh, HyeRin; Lee, Jong-Tae; Yoon, Yoo Sang; Rhee, Byoung Doo

    2015-12-01

    The purpose of this report was to describe our experience in planning and developing a portfolio for a clinical clerkship curriculum. We have developed a portfolio for assessing student competency since 2007. During an annual workshop on clinical clerkship curricula, clerkship directors from five Paik hospitals of Inje University met to improve the assessment of the portfolio. We generated templates for students to record their activities and reflection and receive feedback. We uploaded these templates to our school's website for students to download freely. Annually, we have held a faculty development seminar and a workshop for portfolio assessment and feedback. Also, we established an orientation program on how to construct a learning portfolio for students. Future actions include creating a ubiquitous portfolio system, extending the portfolio to the entire curriculum, setting up an advisor system, and managing the quality of the portfolio. This study could be helpful for medical schools that plan to improve their portfolio assessment with an outcome-based approach.

  5. A novel cloning template designing method by using an artificial bee colony algorithm for edge detection of CNN based imaging sensors.

    PubMed

    Parmaksızoğlu, Selami; Alçı, Mustafa

    2011-01-01

    Cellular Neural Networks (CNNs) have been widely used recently in applications such as edge detection, noise reduction and object detection, which are among the main computer imaging processes. They can also be realized as hardware based imaging sensors. The fact that hardware CNN models produce robust and effective results has attracted the attention of researchers using these structures within image sensors. Realization of desired CNN behavior such as edge detection can be achieved by correctly setting a cloning template without changing the structure of the CNN. To achieve different behaviors effectively, designing a cloning template is one of the most important research topics in this field. In this study, the edge detecting process that is used as a preliminary process for segmentation, identification and coding applications is conducted by using CNN structures. In order to design the cloning template of goal-oriented CNN architecture, an Artificial Bee Colony (ABC) algorithm which is inspired from the foraging behavior of honeybees is used and the performance analysis of ABC for this application is examined with multiple runs. The CNN template generated by the ABC algorithm is tested by using artificial and real test images. The results are subjectively and quantitatively compared with well-known classical edge detection methods, and other CNN based edge detector cloning templates available in the imaging literature. The results show that the proposed method is more successful than other methods.

  6. A Novel Cloning Template Designing Method by Using an Artificial Bee Colony Algorithm for Edge Detection of CNN Based Imaging Sensors

    PubMed Central

    Parmaksızoğlu, Selami; Alçı, Mustafa

    2011-01-01

    Cellular Neural Networks (CNNs) have been widely used recently in applications such as edge detection, noise reduction and object detection, which are among the main computer imaging processes. They can also be realized as hardware based imaging sensors. The fact that hardware CNN models produce robust and effective results has attracted the attention of researchers using these structures within image sensors. Realization of desired CNN behavior such as edge detection can be achieved by correctly setting a cloning template without changing the structure of the CNN. To achieve different behaviors effectively, designing a cloning template is one of the most important research topics in this field. In this study, the edge detecting process that is used as a preliminary process for segmentation, identification and coding applications is conducted by using CNN structures. In order to design the cloning template of goal-oriented CNN architecture, an Artificial Bee Colony (ABC) algorithm which is inspired from the foraging behavior of honeybees is used and the performance analysis of ABC for this application is examined with multiple runs. The CNN template generated by the ABC algorithm is tested by using artificial and real test images. The results are subjectively and quantitatively compared with well-known classical edge detection methods, and other CNN based edge detector cloning templates available in the imaging literature. The results show that the proposed method is more successful than other methods. PMID:22163903

  7. Enserch Garden Banks 388 field development template tie-back of existing subsea satellite wells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hellums, J.W.; Granhaug, O.

    1995-12-31

    The Flowline Jumper System (FJS) will be used by Enserch Exploration, Inc. to tie in three existing wells to the 24 well production template installed in Garden Banks Block 388. The FJS allows these existing satellite wells to be connected to the production template via standard wellbays, eliminating the need for dedicated receiver structures, or tie-in porches. Wellbays used for satellite well tie-ins are available for use as template wells following the removal of the jumper. This paper describes the considerations that led to the selection and influenced the design of the FJS. The advantages of vertical jumper systems aremore » fully discussed with respect to the GB-388 Project. A description of the major components and how they interface with the template is included to provide a better understanding of the FJS. Also included is an outline of the System Integration Testing (SIT) of the FJS.« less

  8. Georeferencing the Large-Scale Aerial Photographs of a Great Lakes Coastal Wetland: A Modified Photogrammetric Method

    USGS Publications Warehouse

    Murphy, Marilyn K.; Kowalski, Kurt P.; Grapentine, Joel L.

    2010-01-01

    The geocontrol template method was developed to georeference multiple, overlapping analog aerial photographs without reliance upon conventionally obtained horizontal ground control. The method was tested as part of a long-term wetland habitat restoration project at a Lake Erie coastal wetland complex in the U.S. Fish and Wildlife Service Ottawa National Wildlife Refuge. As in most coastal wetlands, annually identifiable ground-control features required to georeference photo-interpreted data are difficult to find. The geocontrol template method relies on the following four components: (a) an uncontrolled aerial photo mosaic of the study area, (b) global positioning system (GPS) derived horizontal coordinates of each photo’s principal point, (c) a geocontrol template created by the transfer of fiducial markings and calculated principal points to clear acetate from individual photographs arranged in a mosaic, and (d) the root-mean-square-error testing of the system to ensure an acceptable level of planimetric accuracy. Once created for a study area, the geocontrol template can be registered in geographic information system (GIS) software to facilitate interpretation of multiple images without individual image registration. The geocontrol template enables precise georeferencing of single images within larger blocks of photographs using a repeatable and consistent method.

  9. Facilitating NASA's Use of GEIA-STD-0005-1, Performance Standard for Aerospace and High Performance Electronic Systems Containing Lead-Free Solder

    NASA Technical Reports Server (NTRS)

    Plante, Jeannete

    2010-01-01

    GEIA-STD-0005-1 defines the objectives of, and requirements for, documenting processes that assure customers and regulatory agencies that AHP electronic systems containing lead-free solder, piece parts, and boards will satisfy the applicable requirements for performance, reliability, airworthiness, safety, and certify-ability throughout the specified life of performance. It communicates requirements for a Lead-Free Control Plan (LFCP) to assist suppliers in the development of their own Plans. The Plan documents the Plan Owner's (supplier's) processes, that assure their customer, and all other stakeholders that the Plan owner's products will continue to meet their requirements. The presentation reviews quality assurance requirements traceability and LFCP template instructions.

  10. Full-Waveform Envelope Templates for Low Magnitude Discrimination and Yield Estimation at Local and Regional Distances with Application to the North Korean Nuclear Tests

    NASA Astrophysics Data System (ADS)

    Yoo, S. H.

    2017-12-01

    Monitoring seismologists have successfully used seismic coda for event discrimination and yield estimation for over a decade. In practice seismologists typically analyze long-duration, S-coda signals with high signal-to-noise ratios (SNR) at regional and teleseismic distances, since the single back-scattering model reasonably predicts decay of the late coda. However, seismic monitoring requirements are shifting towards smaller, locally recorded events that exhibit low SNR and short signal lengths. To be successful at characterizing events recorded at local distances, we must utilize the direct-phase arrivals, as well as the earlier part of the coda, which is dominated by multiple forward scattering. To remedy this problem, we have developed a new hybrid method known as full-waveform envelope template matching to improve predicted envelope fits over the entire waveform and account for direct-wave and early coda complexity. We accomplish this by including a multiple forward-scattering approximation in the envelope modeling of the early coda. The new hybrid envelope templates are designed to fit local and regional full waveforms and produce low-variance amplitude estimates, which will improve yield estimation and discrimination between earthquakes and explosions. To demonstrate the new technique, we applied our full-waveform envelope template-matching method to the six known North Korean (DPRK) underground nuclear tests and four aftershock events following the September 2017 test. We successfully discriminated the event types and estimated the yield for all six nuclear tests. We also applied the same technique to the 2015 Tianjin explosions in China, and another suspected low-yield explosion at the DPRK test site on May 12, 2010. Our results show that the new full-waveform envelope template-matching method significantly improves upon longstanding single-scattering coda prediction techniques. More importantly, the new method allows monitoring seismologists to extend coda-based techniques to lower magnitude thresholds and low-yield local explosions.

  11. Individualized 3D printing navigation template for pedicle screw fixation in upper cervical spine

    PubMed Central

    Guo, Fei; Dai, Jianhao; Zhang, Junxiang; Ma, Yichuan; Zhu, Guanghui; Shen, Junjie; Niu, Guoqi

    2017-01-01

    Purpose Pedicle screw fixation in the upper cervical spine is a difficult and high-risk procedure. The screw is difficult to place rapidly and accurately, and can lead to serious injury of spinal cord or vertebral artery. The aim of this study was to design an individualized 3D printing navigation template for pedicle screw fixation in the upper cervical spine. Methods Using CT thin slices data, we employed computer software to design the navigation template for pedicle screw fixation in the upper cervical spine (atlas and axis). The upper cervical spine models and navigation templates were produced by 3D printer with equal proportion, two sets for each case. In one set (Test group), pedicle screws fixation were guided by the navigation template; in the second set (Control group), the screws were fixed under fluoroscopy. According to the degree of pedicle cortex perforation and whether the screw needed to be refitted, the fixation effects were divided into 3 types: Type I, screw is fully located within the vertebral pedicle; Type II, degree of pedicle cortex perforation is <1 mm, but with good internal fixation stability and no need to renovate; Type III, degree of pedicle cortex perforation is >1 mm or with the poor internal fixation stability and in need of renovation. Type I and Type II were acceptable placements; Type III placements were unacceptable. Results A total of 19 upper cervical spine and 19 navigation templates were printed, and 37 pedicle screws were fixed in each group. Type I screw-placements in the test group totaled 32; Type II totaled 3; and Type III totaled 2; with an acceptable rate of 94.60%. Type I screw placements in the control group totaled 23; Type II totaled 3; and Type III totaled 11, with an acceptable rate of 70.27%. The acceptability rate in test group was higher than the rate in control group. The operation time and fluoroscopic frequency for each screw were decreased, compared with control group. Conclusion The individualized 3D printing navigation template for pedicle screw fixation is easy and safe, with a high success rate in the upper cervical spine surgery. PMID:28152039

  12. Individualized 3D printing navigation template for pedicle screw fixation in upper cervical spine.

    PubMed

    Guo, Fei; Dai, Jianhao; Zhang, Junxiang; Ma, Yichuan; Zhu, Guanghui; Shen, Junjie; Niu, Guoqi

    2017-01-01

    Pedicle screw fixation in the upper cervical spine is a difficult and high-risk procedure. The screw is difficult to place rapidly and accurately, and can lead to serious injury of spinal cord or vertebral artery. The aim of this study was to design an individualized 3D printing navigation template for pedicle screw fixation in the upper cervical spine. Using CT thin slices data, we employed computer software to design the navigation template for pedicle screw fixation in the upper cervical spine (atlas and axis). The upper cervical spine models and navigation templates were produced by 3D printer with equal proportion, two sets for each case. In one set (Test group), pedicle screws fixation were guided by the navigation template; in the second set (Control group), the screws were fixed under fluoroscopy. According to the degree of pedicle cortex perforation and whether the screw needed to be refitted, the fixation effects were divided into 3 types: Type I, screw is fully located within the vertebral pedicle; Type II, degree of pedicle cortex perforation is <1 mm, but with good internal fixation stability and no need to renovate; Type III, degree of pedicle cortex perforation is >1 mm or with the poor internal fixation stability and in need of renovation. Type I and Type II were acceptable placements; Type III placements were unacceptable. A total of 19 upper cervical spine and 19 navigation templates were printed, and 37 pedicle screws were fixed in each group. Type I screw-placements in the test group totaled 32; Type II totaled 3; and Type III totaled 2; with an acceptable rate of 94.60%. Type I screw placements in the control group totaled 23; Type II totaled 3; and Type III totaled 11, with an acceptable rate of 70.27%. The acceptability rate in test group was higher than the rate in control group. The operation time and fluoroscopic frequency for each screw were decreased, compared with control group. The individualized 3D printing navigation template for pedicle screw fixation is easy and safe, with a high success rate in the upper cervical spine surgery.

  13. Integration of 3D anatomical data obtained by CT imaging and 3D optical scanning for computer aided implant surgery

    PubMed Central

    2011-01-01

    Background A precise placement of dental implants is a crucial step to optimize both prosthetic aspects and functional constraints. In this context, the use of virtual guiding systems has been recognized as a fundamental tool to control the ideal implant position. In particular, complex periodontal surgeries can be performed using preoperative planning based on CT data. The critical point of the procedure relies on the lack of accuracy in transferring CT planning information to surgical field through custom-made stereo-lithographic surgical guides. Methods In this work, a novel methodology is proposed for monitoring loss of accuracy in transferring CT dental information into periodontal surgical field. The methodology is based on integrating 3D data of anatomical (impression and cast) and preoperative (radiographic template) models, obtained by both CT and optical scanning processes. Results A clinical case, relative to a fully edentulous jaw patient, has been used as test case to assess the accuracy of the various steps concurring in manufacturing surgical guides. In particular, a surgical guide has been designed to place implants in the bone structure of the patient. The analysis of the results has allowed the clinician to monitor all the errors, which have been occurring step by step manufacturing the physical templates. Conclusions The use of an optical scanner, which has a higher resolution and accuracy than CT scanning, has demonstrated to be a valid support to control the precision of the various physical models adopted and to point out possible error sources. A case study regarding a fully edentulous patient has confirmed the feasibility of the proposed methodology. PMID:21338504

  14. The center for expanded data annotation and retrieval

    PubMed Central

    Bean, Carol A; Cheung, Kei-Hoi; Dumontier, Michel; Durante, Kim A; Gevaert, Olivier; Gonzalez-Beltran, Alejandra; Khatri, Purvesh; Kleinstein, Steven H; O’Connor, Martin J; Pouliot, Yannick; Rocca-Serra, Philippe; Sansone, Susanna-Assunta; Wiser, Jeffrey A

    2015-01-01

    The Center for Expanded Data Annotation and Retrieval is studying the creation of comprehensive and expressive metadata for biomedical datasets to facilitate data discovery, data interpretation, and data reuse. We take advantage of emerging community-based standard templates for describing different kinds of biomedical datasets, and we investigate the use of computational techniques to help investigators to assemble templates and to fill in their values. We are creating a repository of metadata from which we plan to identify metadata patterns that will drive predictive data entry when filling in metadata templates. The metadata repository not only will capture annotations specified when experimental datasets are initially created, but also will incorporate links to the published literature, including secondary analyses and possible refinements or retractions of experimental interpretations. By working initially with the Human Immunology Project Consortium and the developers of the ImmPort data repository, we are developing and evaluating an end-to-end solution to the problems of metadata authoring and management that will generalize to other data-management environments. PMID:26112029

  15. The Design of a Templated C++ Small Vector Class for Numerical Computing

    NASA Technical Reports Server (NTRS)

    Moran, Patrick J.

    2000-01-01

    We describe the design and implementation of a templated C++ class for vectors. The vector class is templated both for vector length and vector component type; the vector length is fixed at template instantiation time. The vector implementation is such that for a vector of N components of type T, the total number of bytes required by the vector is equal to N * size of (T), where size of is the built-in C operator. The property of having a size no bigger than that required by the components themselves is key in many numerical computing applications, where one may allocate very large arrays of small, fixed-length vectors. In addition to the design trade-offs motivating our fixed-length vector design choice, we review some of the C++ template features essential to an efficient, succinct implementation. In particular, we highlight some of the standard C++ features, such as partial template specialization, that are not supported by all compilers currently. This report provides an inventory listing the relevant support currently provided by some key compilers, as well as test code one can use to verify compiler capabilities.

  16. A template-finding algorithm and a comprehensive benchmark for homology modeling of proteins

    PubMed Central

    Vallat, Brinda Kizhakke; Pillardy, Jaroslaw; Elber, Ron

    2010-01-01

    The first step in homology modeling is to identify a template protein for the target sequence. The template structure is used in later phases of the calculation to construct an atomically detailed model for the target. We have built from the Protein Data Bank a large-scale learning set that includes tens of millions of pair matches that can be either a true template or a false one. Discriminatory learning (learning from positive and negative examples) is employed to train a decision tree. Each branch of the tree is a mathematical programming model. The decision tree is tested on an independent set from PDB entries and on the sequences of CASP7. It provides significant enrichment of true templates (between 50-100 percent) when compared to PSI-BLAST. The model is further verified by building atomically detailed structures for each of the tentative true templates with modeller. The probability that a true match does not yield an acceptable structural model (within 6Å RMSD from the native structure), decays linearly as a function of the TM structural-alignment score. PMID:18300226

  17. Evaluating patients' comprehensibility of a standardized medication plan.

    PubMed

    Botermann, Lea; Monzel, Katharina; Krueger, Katrin; Eickhoff, Christiane; Wachter, Angelika; Kloft, Charlotte; Laufs, Ulrich; Schulz, Martin

    2016-10-01

    A standardized medication plan for patients has been developed and recently enacted into German law depicting all medicines taken. It can only increase medication safety if patients use and understand it. We evaluated patients' comprehensibility of the medication plan and analyzed potential variables influencing patients' understanding. The medication plan template v2.0 was first tested in N = 40 patients, and the "Evaluation Tool to test the handling of the Medication Plan" (ET-MP) was developed, rating patients' understanding from 0 to 100 %. The cut-off, distinguishing if patients understand the medication plan, was set at 90 %. The ET-MP was then applied to an amended medication plan questioning N = 40 general internal medicine (GIM) and N = 50 patients with chronic heart failure (CHF). The mean (± standard deviation (SD)) age of the study cohort was 69 ± 13 years, 47 % female. Patients took 8 ± 3 drugs chronically. The CHF patients had a lower level of education compared to the GIM group (p = 0.004). The overall ET-MP score was 82 ± 21 % (GIM 86 ± 19 %, CHF 78 ± 23 %; p = 0.16). Forty-three percent achieved a score >90 %. A moderate correlation was found between the ET-MP score and the level of education (r = 0.45) and age (r = -0.46), respectively (both p < 0.001). Cognitively impaired CHF patients (p = 0.03) and patients with advanced CHF (p = 0.006) achieved a lower ET-MP score. In the CHF cohort, signs of depression or a lower level of self-care behaviour were not associated with a lower ET-MP score. The ET-MP is suitable to explore patients' understanding of a medication plan. Less than 50 % of the patients reached a score above 90 %. Higher age and lower level of education but not the diagnosis of CHF seem to correlate with impaired understanding of the standardized medication plan. In addition to a medication plan, a significant number of patients are in need of further and continuous care to improve medication safety.

  18. The construction of 3D-engineered tissues composed of cells and extracellular matrices by hydrogel template approach.

    PubMed

    Matsusaki, Michiya; Yoshida, Hiroaki; Akashi, Mitsuru

    2007-06-01

    The three-dimensional (3D)-engineered tissues composed of only cells and extracellular matrices (ECM) were constructed by the hydrogel template approach. The disulfide-crosslinked poly(gamma-glutamic acid) hydrogels were prepared as a template hydrogel. These template hydrogels were easily decomposed under physiological conditions using reductants such as cysteine, glutathione and dithiothreitol by cleavage of disulfide crosslinkage to thiol groups. The decomposed polymers are soluble in cell culture medium. The cleaving of disulfide bond was determined by UV-vis and FT-IR spectroscopies. We successfully prepared the 3D-engineered tissues (thickness/diameter, 2mm/1cm) composed of mouse L929 fibroblast cells and ECM by the decomposition of only the template hydrogel with cysteine after 10 days 3D-cell culture on/in the template hydrogel. The size and thickness of the 3D-engineered tissues was completely transferred from the template hydrogel. The cultured L929 cells viability in the obtained engineered tissues was confirmed by a culture test, WST-1 method and LIVE/DEAD staining assay. The engineered tissue was self-standing and highly dense composite of the cultured cells and collagen produced by the cells. This hydrogel template approach may be useful as a new class of soft-tissue engineering technology to substitute a synthetic polymer scaffold to the ECM scaffold produced from the cultured cells.

  19. An automatic search of Alzheimer patterns using a nonnegative matrix factorization

    NASA Astrophysics Data System (ADS)

    Giraldo, Diana L.; García-Arteaga, Juan D.; Romero, Eduardo

    2013-11-01

    This paper presents a fully automatic method that condenses relevant morphometric information from a database of magnetic resonance images (MR) labeled as either normal (NC) or Alzheimer's disease (AD). The proposed method generates class templates using Nonnegative Matrix Factorization (NMF) which will be used to develop an NC/AD classi cator. It then nds regions of interest (ROI) with discerning inter-class properties. by inspecting the di erence volume of the two class templates. From these templates local probability distribution functions associated to low level features such as intensities, orientation and edges within the found ROI are calculated. A sample brain volume can then be characterized by a similarity measure in the ROI to both the normal and the pathological templates. These characteristics feed a simple binary SVM classi er which, when tested with an experimental group extracted from a public brain MR dataset (OASIS), reveals an equal error rate measure which is better than the state-of-the-art tested on the same dataset (0:9 in the former and 0:8 in the latter).

  20. Solid waste management complex site development plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Greager, T.M.

    1994-09-30

    The main purpose of this Solid Waste Management Complex Site Development Plan is to optimize the location of future solid waste treatment and storage facilities and the infrastructure required to support them. An overall site plan is recommended. Further, a series of layouts are included that depict site conditions as facilities are constructed at the SWMC site. In this respect the report serves not only as the siting basis for future projects, but provides siting guidance for Project W-112, as well. The plan is intended to function as a template for expected growth of the site over the next 30more » years so that future facilities and infrastructure will be properly integrated.« less

  1. Virtual surgical planning and 3D printing in repeat calvarial vault reconstruction for craniosynostosis: technical note.

    PubMed

    LoPresti, Melissa; Daniels, Bradley; Buchanan, Edward P; Monson, Laura; Lam, Sandi

    2017-04-01

    Repeat surgery for restenosis after initial nonsyndromic craniosynostosis intervention is sometimes needed. Calvarial vault reconstruction through a healed surgical bed adds a level of intraoperative complexity and may benefit from preoperative and intraoperative definitions of biometric and aesthetic norms. Computer-assisted design and manufacturing using 3D imaging allows the precise formulation of operative plans in anticipation of surgical intervention. 3D printing turns virtual plans into anatomical replicas, templates, or customized implants by using a variety of materials. The authors present a technical note illustrating the use of this technology: a repeat calvarial vault reconstruction that was planned and executed using computer-assisted design and 3D printed intraoperative guides.

  2. PechaKucha Presentations: Teaching Storytelling, Visual Design, and Conciseness

    ERIC Educational Resources Information Center

    Lucas, Kristen; Rawlins, Jacob D.

    2015-01-01

    When speakers rely too heavily on presentation software templates, they often end up stultifying audiences with a triple-whammy of bullet points. In this article, Lucas and Rawlins present an alternative method--PechaKucha (the Japanese word for "chit chat")--a presentation style driven by a carefully planned, automatically timed…

  3. 76 FR 57744 - Agency Information Collection Activities: Submission for OMB Review; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-16

    ... of forms necessary to conduct ongoing business with State partners in the implementation of Medicaid... reporting templates. The development of streamlined submission forms is critical for States to implement... requests for State plan amendments, waivers, and demonstration, as well as ongoing reporting.; Form Number...

  4. A Mindfulness-Based Cognitive Psychoeducational Group Manual for Problem Gambling

    ERIC Educational Resources Information Center

    Cormier, Abigail; McBride, Dawn Lorraine

    2012-01-01

    This project provides a comprehensive overview of the research literature on problem gambling in adults and includes a detailed mindfulness-based psychoeducational group manual for problem gambling, complete with an extensive group counselling consent form, assessment and screening protocols, 10 user-friendly lesson plans, templates for a…

  5. Enterprise Resource Planning Systems Schedule Delays and Reengineering Weaknesses Increase Risks to DoD’s Auditability Goals

    DTIC Science & Technology

    2012-07-13

    completed through SAP -standard templates that are then used for gap analysis as compared to the commercial-off-the-shelf “To-Be” process. The Navy ERP ...13F25-04 4800 Mark Center Drive Alexandria, VA 22350-1500 Acronyms and Abbreviations BPR CMO DAI DCMO DEAMS DLA EBS EC ERP FIAR GAO...overall objective was to evaluate six Enterprise Resource Planning ( ERP ) systems that we identified as necessary for DoD to produce auditable

  6. I-TASSER: fully automated protein structure prediction in CASP8.

    PubMed

    Zhang, Yang

    2009-01-01

    The I-TASSER algorithm for 3D protein structure prediction was tested in CASP8, with the procedure fully automated in both the Server and Human sections. The quality of the server models is close to that of human ones but the human predictions incorporate more diverse templates from other servers which improve the human predictions in some of the distant homology targets. For the first time, the sequence-based contact predictions from machine learning techniques are found helpful for both template-based modeling (TBM) and template-free modeling (FM). In TBM, although the accuracy of the sequence based contact predictions is on average lower than that from template-based ones, the novel contacts in the sequence-based predictions, which are complementary to the threading templates in the weakly or unaligned regions, are important to improve the global and local packing in these regions. Moreover, the newly developed atomic structural refinement algorithm was tested in CASP8 and found to improve the hydrogen-bonding networks and the overall TM-score, which is mainly due to its ability of removing steric clashes so that the models can be generated from cluster centroids. Nevertheless, one of the major issues of the I-TASSER pipeline is the model selection where the best models could not be appropriately recognized when the correct templates are detected only by the minority of the threading algorithms. There are also problems related with domain-splitting and mirror image recognition which mainly influences the performance of I-TASSER modeling in the FM-based structure predictions. Copyright 2009 Wiley-Liss, Inc.

  7. Prediction of Protein Structure by Template-Based Modeling Combined with the UNRES Force Field.

    PubMed

    Krupa, Paweł; Mozolewska, Magdalena A; Joo, Keehyoung; Lee, Jooyoung; Czaplewski, Cezary; Liwo, Adam

    2015-06-22

    A new approach to the prediction of protein structures that uses distance and backbone virtual-bond dihedral angle restraints derived from template-based models and simulations with the united residue (UNRES) force field is proposed. The approach combines the accuracy and reliability of template-based methods for the segments of the target sequence with high similarity to those having known structures with the ability of UNRES to pack the domains correctly. Multiplexed replica-exchange molecular dynamics with restraints derived from template-based models of a given target, in which each restraint is weighted according to the accuracy of the prediction of the corresponding section of the molecule, is used to search the conformational space, and the weighted histogram analysis method and cluster analysis are applied to determine the families of the most probable conformations, from which candidate predictions are selected. To test the capability of the method to recover template-based models from restraints, five single-domain proteins with structures that have been well-predicted by template-based methods were used; it was found that the resulting structures were of the same quality as the best of the original models. To assess whether the new approach can improve template-based predictions with incorrectly predicted domain packing, four such targets were selected from the CASP10 targets; for three of them the new approach resulted in significantly better predictions compared with the original template-based models. The new approach can be used to predict the structures of proteins for which good templates can be found for sections of the sequence or an overall good template can be found for the entire sequence but the prediction quality is remarkably weaker in putative domain-linker regions.

  8. GalaxyGPCRloop: Template-Based and Ab Initio Structure Sampling of the Extracellular Loops of G-Protein-Coupled Receptors.

    PubMed

    Won, Jonghun; Lee, Gyu Rie; Park, Hahnbeom; Seok, Chaok

    2018-06-07

    The second extracellular loops (ECL2s) of G-protein-coupled receptors (GPCRs) are often involved in GPCR functions, and their structures have important implications in drug discovery. However, structure prediction of ECL2 is difficult because of its long length and the structural diversity among different GPCRs. In this study, a new ECL2 conformational sampling method involving both template-based and ab initio sampling was developed. Inspired by the observation of similar ECL2 structures of closely related GPCRs, a template-based sampling method employing loop structure templates selected from the structure database was developed. A new metric for evaluating similarity of the target loop to templates was introduced for template selection. An ab initio loop sampling method was also developed to treat cases without highly similar templates. The ab initio method is based on the previously developed fragment assembly and loop closure method. A new sampling component that takes advantage of secondary structure prediction was added. In addition, a conserved disulfide bridge restraining ECL2 conformation was predicted and analytically incorporated into sampling, reducing the effective dimension of the conformational search space. The sampling method was combined with an existing energy function for comparison with previously reported loop structure prediction methods, and the benchmark test demonstrated outstanding performance.

  9. Geometrical modeling of complete dental shapes by using panoramic X-ray, digital mouth data and anatomical templates.

    PubMed

    Barone, Sandro; Paoli, Alessandro; Razionale, Armando Viviano

    2015-07-01

    In the field of orthodontic planning, the creation of a complete digital dental model to simulate and predict treatments is of utmost importance. Nowadays, orthodontists use panoramic radiographs (PAN) and dental crown representations obtained by optical scanning. However, these data do not contain any 3D information regarding tooth root geometries. A reliable orthodontic treatment should instead take into account entire geometrical models of dental shapes in order to better predict tooth movements. This paper presents a methodology to create complete 3D patient dental anatomies by combining digital mouth models and panoramic radiographs. The modeling process is based on using crown surfaces, reconstructed by optical scanning, and root geometries, obtained by adapting anatomical CAD templates over patient specific information extracted from radiographic data. The radiographic process is virtually replicated on crown digital geometries through the Discrete Radon Transform (DRT). The resulting virtual PAN image is used to integrate the actual radiographic data and the digital mouth model. This procedure provides the root references on the 3D digital crown models, which guide a shape adjustment of the dental CAD templates. The entire geometrical models are finally created by merging dental crowns, captured by optical scanning, and root geometries, obtained from the CAD templates. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Plasmodium vivax molecular diagnostics in community surveys: pitfalls and solutions.

    PubMed

    Gruenberg, Maria; Moniz, Clara Antunes; Hofmann, Natalie Ellen; Wampfler, Rahel; Koepfli, Cristian; Mueller, Ivo; Monteiro, Wuelton Marcelo; Lacerda, Marcus; de Melo, Gisely Cardoso; Kuehn, Andrea; Siqueira, Andre M; Felger, Ingrid

    2018-01-30

    A distinctive feature of Plasmodium vivax infections is the overall low parasite density in peripheral blood. Thus, identifying asymptomatic infected individuals in endemic communities requires diagnostic tests with high sensitivity. The detection limits of molecular diagnostic tests are primarily defined by the volume of blood analysed and by the copy number of the amplified molecular marker serving as the template for amplification. By using mitochondrial DNA as the multi-copy template, the detection limit can be improved more than tenfold, compared to standard 18S rRNA targets, thereby allowing detection of lower parasite densities. In a very low transmission area in Brazil, application of a mitochondrial DNA-based assay increased prevalence from 4.9 to 6.5%. The usefulness of molecular tests in malaria epidemiological studies is widely recognized, especially when precise prevalence rates are desired. Of concern, however, is the challenge of demonstrating test accuracy and quality control for samples with very low parasite densities. In this case, chance effects in template distribution around the detection limit constrain reproducibility. Rigorous assessment of false positive and false negative test results is, therefore, required to prevent over- or under-estimation of parasite prevalence in epidemiological studies or when monitoring interventions.

  11. Template-assisted electrostatic spray deposition as a new route to mesoporous, macroporous, and hierarchically porous oxide films.

    PubMed

    Sokolov, S; Paul, B; Ortel, E; Fischer, A; Kraehnert, R

    2011-03-01

    A novel film coating technique, template-assisted electrostatic spray deposition (TAESD), was developed for the synthesis of porous metal oxide films and tested on TiO(2). Organic templates are codeposited with the titania precursor by electrostatic spray deposition and then removed during calcination. Resultant films are highly porous with pores casted by uniformly sized templates, which introduced a new level of control over the pore morphology for the ESD method. Employing the amphiphilic block copolymer Pluronic P123, PMMA latex spheres, or a combination of the two, mesoporous, macroporous, and hierarchically porous TiO(2) films are obtained. Decoupled from other coating parameters, film thickness can be controlled by deposition time or depositing multiple layers while maintaining the coating's structure and integrity.

  12. Construction of optimal 3-node plate bending triangles by templates

    NASA Astrophysics Data System (ADS)

    Felippa, C. A.; Militello, C.

    A finite element template is a parametrized algebraic form that reduces to specific finite elements by setting numerical values to the free parameters. The present study concerns Kirchhoff Plate-Bending Triangles (KPT) with 3 nodes and 9 degrees of freedom. A 37-parameter template is constructed using the Assumed Natural Deviatoric Strain (ANDES). Specialization of this template includes well known elements such as DKT and HCT. The question addressed here is: can these parameters be selected to produce high performance elements? The study is carried out by staged application of constraints on the free parameters. The first stage produces element families satisfying invariance and aspect ratio insensitivity conditions. Application of energy balance constraints produces specific elements. The performance of such elements in benchmark tests is presently under study.

  13. Matching organic libraries with protein-substructures

    NASA Astrophysics Data System (ADS)

    Preissner, R.; Goede, A.; Rother, K.; Osterkamp, F.; Koert, U.; Froemmel, C.

    2001-09-01

    We present a general approach which allows automatic identification of sub-structures in proteins that resemble given three-dimensional templates. This paper documents its success with non-peptide templates such as β-turn mimetics. We considered well-tested turn-mimetics such as the bicyclic turned dipeptide (BTD), spiro lactam (Spiro) and the 2,5-disubstituded tetrahydrofuran (THF), a new furan-derivative which was recently developed and characterized. The detected geometric similarity between the templates and the protein patches corresponds to r.m.s.-values of 0.3 Å for more than 80% of the constituting atoms, which is typical for active site comparisons of homologous proteins. This fast automatic procedure might be of biomedical value for finding special mimicking leads for particular protein sub-structures as well as for template-assembled synthetic protein (TASP) design.

  14. Long-chain amine-templated synthesis of gallium sulfide and gallium selenide nanotubes

    NASA Astrophysics Data System (ADS)

    Seral-Ascaso, A.; Metel, S.; Pokle, A.; Backes, C.; Zhang, C. J.; Nerl, H. C.; Rode, K.; Berner, N. C.; Downing, C.; McEvoy, N.; Muñoz, E.; Harvey, A.; Gholamvand, Z.; Duesberg, G. S.; Coleman, J. N.; Nicolosi, V.

    2016-06-01

    We describe the soft chemistry synthesis of amine-templated gallium chalcogenide nanotubes through the reaction of gallium(iii) acetylacetonate and the chalcogen (sulfur, selenium) using a mixture of long-chain amines (hexadecylamine and dodecylamine) as a solvent. Beyond their role as solvent, the amines also act as a template, directing the growth of discrete units with a one-dimensional multilayer tubular nanostructure. These new materials, which broaden the family of amine-stabilized gallium chalcogenides, can be tentatively classified as direct large band gap semiconductors. Their preliminary performance as active material for electrodes in lithium ion batteries has also been tested, demonstrating great potential in energy storage field even without optimization.We describe the soft chemistry synthesis of amine-templated gallium chalcogenide nanotubes through the reaction of gallium(iii) acetylacetonate and the chalcogen (sulfur, selenium) using a mixture of long-chain amines (hexadecylamine and dodecylamine) as a solvent. Beyond their role as solvent, the amines also act as a template, directing the growth of discrete units with a one-dimensional multilayer tubular nanostructure. These new materials, which broaden the family of amine-stabilized gallium chalcogenides, can be tentatively classified as direct large band gap semiconductors. Their preliminary performance as active material for electrodes in lithium ion batteries has also been tested, demonstrating great potential in energy storage field even without optimization. Electronic supplementary information (ESI) available. See DOI: 10.1039/c6nr01663d

  15. A Cost-Effective, In-House, Positioning and Cutting Guide System for Orthognathic Surgery.

    PubMed

    McAllister, Peter; Watson, Melanie; Burke, Ezra

    2018-03-01

    Technological advances in 3D printing can dramatically improve orthognathic surgical planning workflow. Custom positioning and cutting guides enable intraoperative reproduction of pre-planned osteotomy cuts and can result in greater surgical accuracy and patient safety. This short paper describes the use of freeware (some with open-source) combined with in-house 3D printing facilities to produce reliable, affordable osteotomy cutting guides. Open-source software (3D Slicer) is used to visualise and segment three-dimensional planning models from imported conventional computed tomography (CT) scans. Freeware (Autodesk Meshmixer ©) allows digital manipulation of maxillary and mandibular components to plan precise osteotomy cuts. Bespoke cutting guides allow exact intraoperative positioning. These are printed in polylactic acid (PLA) using a fused-filament fabrication 3D printer. Fixation of the osteotomised segments is achieved using plating templates and four pre-adapted plates with planned screw holes over the thickest bone. We print maxilla/ mandible models with desired movements incorporated to use as a plating template. A 3D printer capable of reproducing a complete skull can be procured for £1000, with material costs in the region of £10 per case. Our production of models and guides typically takes less than 24 hours of total print time. The entire production process is frequently less than three days. Externally sourced models and guides cost significantly more, frequently encountering costs totalling £1500-£2000 for models and guides for a bimaxillary osteotomy. Three-dimensional guided surgical planning utilising custom cutting guides enables the surgeon to determine optimal orientation of osteotomy cuts and better predict the skeletal maxilla/mandible relationship following surgery. The learning curve to develop proficiency using planning software and printer settings is offset by increased surgical predictability and reduced theatre time, making this form of planning a worthy investment.

  16. 3D accuracy of implant positions in template-guided implant placement as a function of the remaining teeth and the surgical procedure: a retrospective study.

    PubMed

    Schnutenhaus, Sigmar; Edelmann, Cornelia; Rudolph, Heike; Dreyhaupt, Jens; Luthardt, Ralph G

    2018-01-22

    The aim of this study was to investigate differences between the virtually planned and clinically achieved implant positions in completely template-guided implantations as a function of the type of edentulous space, the residual natural dentition, and the surgical implementation. Fifty-six patient cases with a total of 122 implants were evaluated retrospectively. The implantations were completely template-based. The data of the planned implant positions were overlaid with the actual clinical implant positions, followed by measurements of the 3D deviations in terms of coronal (x c ) and apical distance, height (x h ), and angulation (ang) and statistical analysis. The mean x c was 1.2 mm (SD 0.7 mm); the mean x a was 1.8 mm (SD 0.9 mm), the mean x h was 0.8 mm (SD 0.7 mm); and the mean ang was 4.8° (SD 3.1). The type of edentulous space and the jaw (maxilla/mandible) had no significant effect on the results in terms of implant positions. The presence of an adjacent natural tooth at the time of implantation had a significant influence on x h (p = 0.04) and ang (p = 0.05). No significant differences were found regarding the surgical approach for any of the parameters examined. The results of our study are in the same range as those of other studies. Template-guided implantation offers a high degree of accuracy even in the presence of different configurations of the residual dentition or different surgical approaches. A clinical benefit is therefore present, especially from a prosthetic point of view. The clinically achievable accuracy can be described as sufficient for further prosthetic treatment, given the intrinsic and methodological tolerances, making prosthetic rehabilitation safe and predictable.

  17. Autoclave method for rapid preparation of bacterial PCR-template DNA.

    PubMed

    Simmon, Keith E; Steadman, Dewey D; Durkin, Sarah; Baldwin, Amy; Jeffrey, Wade H; Sheridan, Peter; Horton, Rene; Shields, Malcolm S

    2004-02-01

    An autoclave method for preparing bacterial DNA for PCR template is presented, it eliminates the use of detergents, organic solvents, and mechanical cellular disruption approaches, thereby significantly reducing processing time and costs while increasing reproducibility. Bacteria are lysed by rapid heating and depressurization in an autoclave. The lysate, cleared by microcentrifugation, was either used directly in the PCR reaction, or concentrated by ultrafiltration. This approach was compared with seven established methods of DNA template preparation from four bacterial sources which included boiling Triton X-100 and SDS, bead beating, lysozyme/proteinase K, and CTAB lysis method components. Bacteria examined were Enterococcus and Escherichia coli, a natural marine bacterial community and an Antarctic cyanobacterial-mat. DNAs were tested for their suitability as PCR templates by repetitive element random amplified polymorphic DNA (RAPD) and denaturing gradient gel electrophoresis (DGGE) analysis. The autoclave method produced PCR amplifiable template comparable or superior to the other methods, with greater reproducibility, much shorter processing time, and at a significantly lower cost.

  18. Virtual estimates of fastening strength for pedicle screw implantation procedures

    NASA Astrophysics Data System (ADS)

    Linte, Cristian A.; Camp, Jon J.; Augustine, Kurt E.; Huddleston, Paul M.; Robb, Richard A.; Holmes, David R.

    2014-03-01

    Traditional 2D images provide limited use for accurate planning of spine interventions, mainly due to the complex 3D anatomy of the spine and close proximity of nerve bundles and vascular structures that must be avoided during the procedure. Our previously developed clinician-friendly platform for spine surgery planning takes advantage of 3D pre-operative images, to enable oblique reformatting and 3D rendering of individual or multiple vertebrae, interactive templating, and placement of virtual pedicle implants. Here we extend the capabilities of the planning platform and demonstrate how the virtual templating approach not only assists with the selection of the optimal implant size and trajectory, but can also be augmented to provide surrogate estimates of the fastening strength of the implanted pedicle screws based on implant dimension and bone mineral density of the displaced bone substrate. According to the failure theories, each screw withstands a maximum holding power that is directly proportional to the screw diameter (D), the length of the in-bone segm,ent of the screw (L), and the density (i.e., bone mineral density) of the pedicle body. In this application, voxel intensity is used as a surrogate measure of the bone mineral density (BMD) of the pedicle body segment displaced by the screw. We conducted an initial assessment of the developed platform using retrospective pre- and post-operative clinical 3D CT data from four patients who underwent spine surgery, consisting of a total of 26 pedicle screws implanted in the lumbar spine. The Fastening Strength of the planned implants was directly assessed by estimating the intensity - area product across the pedicle volume displaced by the virtually implanted screw. For post-operative assessment, each vertebra was registered to its homologous counterpart in the pre-operative image using an intensity-based rigid registration followed by manual adjustment. Following registration, the Fastening Strength was computed for each displaced bone segment. According to our preliminary clinical study, a comparison between Fastening Strength, displaced bone volume and mean voxel intensity showed similar results (p < 0.1) between the virtually templated plans and the post-operative outcome following the traditional clinical approach. This study has demonstrated the feasibility of the platform in providing estimates the pedicle screw fastening strength via virtual implantation, given the intrinsic vertebral geometry and bone mineral density, enabling the selection of the optimal implant dimension adn trajectory for improved strength.

  19. Estimating B1+ in the breast at 7 T using a generic template.

    PubMed

    van Rijssel, Michael J; Pluim, Josien P W; Luijten, Peter R; Gilhuijs, Kenneth G A; Raaijmakers, Alexander J E; Klomp, Dennis W J

    2018-05-01

    Dynamic contrast-enhanced MRI is the workhorse of breast MRI, where the diagnosis of lesions is largely based on the enhancement curve shape. However, this curve shape is biased by RF transmit (B 1 + ) field inhomogeneities. B 1 + field information is required in order to correct these. The use of a generic, coil-specific B 1 + template is proposed and tested. Finite-difference time-domain simulations for B 1 + were performed for healthy female volunteers with a wide range of breast anatomies. A generic B 1 + template was constructed by averaging simulations based on four volunteers. Three-dimensional B 1 + maps were acquired in 15 other volunteers. Root mean square error (RMSE) metrics were calculated between individual simulations and the template, and between individual measurements and the template. The agreement between the proposed template approach and a B 1 + mapping method was compared against the agreement between acquisition and reacquisition using the same mapping protocol. RMSE values (% of nominal flip angle) comparing individual simulations with the template were in the range 2.00-4.01%, with mean 2.68%. RMSE values comparing individual measurements with the template were in the range8.1-16%, with mean 11.7%. The agreement between the proposed template approach and a B 1 + mapping method was only slightly worse than the agreement between two consecutive acquisitions using the same mapping protocol in one volunteer: the range of agreement increased from ±16% of the nominal angle for repeated measurement to ±22% for the B 1 + template. With local RF transmit coils, intersubject differences in B 1 + fields of the breast are comparable to the accuracy of B 1 + mapping methods, even at 7 T. Consequently, a single generic B 1 + template suits subjects over a wide range of breast anatomies, eliminating the need for a time-consuming B 1 + mapping protocol. © 2018 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd.

  20. Estimating B 1 + in the breast at 7 T using a generic template

    PubMed Central

    Pluim, Josien P. W.; Luijten, Peter R.; Gilhuijs, Kenneth G. A.; Raaijmakers, Alexander J. E.; Klomp, Dennis W. J.

    2018-01-01

    Dynamic contrast‐enhanced MRI is the workhorse of breast MRI, where the diagnosis of lesions is largely based on the enhancement curve shape. However, this curve shape is biased by RF transmit (B 1 +) field inhomogeneities. B 1 + field information is required in order to correct these. The use of a generic, coil‐specific B 1 + template is proposed and tested. Finite‐difference time‐domain simulations for B 1 + were performed for healthy female volunteers with a wide range of breast anatomies. A generic B 1 + template was constructed by averaging simulations based on four volunteers. Three‐dimensional B 1 + maps were acquired in 15 other volunteers. Root mean square error (RMSE) metrics were calculated between individual simulations and the template, and between individual measurements and the template. The agreement between the proposed template approach and a B 1 + mapping method was compared against the agreement between acquisition and reacquisition using the same mapping protocol. RMSE values (% of nominal flip angle) comparing individual simulations with the template were in the range 2.00‐4.01%, with mean 2.68%. RMSE values comparing individual measurements with the template were in the range8.1‐16%, with mean 11.7%. The agreement between the proposed template approach and a B 1 + mapping method was only slightly worse than the agreement between two consecutive acquisitions using the same mapping protocol in one volunteer: the range of agreement increased from ±16% of the nominal angle for repeated measurement to ±22% for the B 1 + template. With local RF transmit coils, intersubject differences in B 1 + fields of the breast are comparable to the accuracy of B 1 + mapping methods, even at 7 T. Consequently, a single generic B 1 + template suits subjects over a wide range of breast anatomies, eliminating the need for a time‐consuming B 1 + mapping protocol. PMID:29570887

  1. The role of an occlusal template during the placement of preformed metal crowns in children under general anaesthesia: a randomised control trial.

    PubMed

    Pani, S C; Dimashkieh, M; Mojaleed, F; Al Shammery, F

    2015-12-01

    This aim was to evaluate preformed metal crowns (PMC) placed under general anaesthesia using an occlusal template in comparison to crowns placed without the use of a template. CONSORT protocols were followed in the design of the study. A total of 60 children between 4-7 years requiring pulpotomy and PMC for all primary molars met the inclusion criteria for this study. The control group comprised patients for whom the PMC were placed without the use of an occlusal template, while in the test group crowns were placed using a polyvinyl siloxane occlusal template. Patients were followed up at 24 h, 7 days, 3 and 6 months. The time taken for the placement of crowns, instances of post-operative discomfort, success or failure of the pulp therapy and loss of any crowns were compared between the groups. The mean time taken for completion of the procedure in the control group was significantly greater than the template group (t = 2.566, p = 0.013). Significantly fewer patients in the template group reported symptoms of discomfort or high points at the 24-h recall; however, these differences were not significant at the 1-week, 3- or 6-month recall. The use of an occlusal template for the placement of multiple PMC under general anaesthesia reduces the time taken for their placement and reduces the incidence of immediate post-operative discomfort.

  2. 78 FR 39305 - 30-Day Notice of Proposed Information Collection: OSHC Progress Report Template

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-01

    ... Building, Washington, DC 20503; fax: 202-395-5806. Email: [email protected] . FOR FURTHER... proposed use: The Appropriations Act, provided a total of $100,000,000 to HUD for a Sustainable Communities... Sustainable Communities Regional Planning Grant Program, and $30,000,000 is available for the Community...

  3. 76 FR 29249 - Agency Information Collection Activities: Submission for OMB Review; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-20

    ... collection; Title of Information Collection: State Plan Template to Implement Section 6062 of the Deficit Reduction Act; Form No.: CMS-10232 (OMB : 0938-1045); Use: The Deficit Reduction Act (DRA) provides States..., 2011. OMB, Office of Information and Regulatory Affairs, Attention: CMS Desk Officer, Fax Number: (202...

  4. Building a Model PE Curriculum: Education Reform in Action

    ERIC Educational Resources Information Center

    Moore, John

    2012-01-01

    The blueprint to build a model physical education (PE) curriculum begins by establishing a sound curricular foundation based on a lesson plan template that incorporates clear and concise program goals, the alignment of lessons to state or national content standards, and the collection, analysis and use of objective assessment data that informs…

  5. Design, fabrication, and integration testing of the Garden Banks 388 subsea production template

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ledbetter, W.R.; Smith, D.W.; Pierce, D.M.

    1995-12-31

    Enserch Exploration`s Garden Banks 388 development has a production scheme based around a floating drilling and production facility and subsea drilling/production template. The Floating Production Facility (FPF) is a converted semisubmersible drilling rig that will drill and produce through a 24-well slot subsea template. This development is located in Block 388 of the Garden Banks area in the Gulf of Mexico approximately 200 miles southwest of New Orleans, Louisiana. The production system is being installed in an area of known oil and gas reserves and will produce to a shallow water platform 54 miles away at Eugene Island 315. Themore » FPF will be permanently moored above the template. The subsea template has been installed in 2190 feet of water and will produce through a 2,000 foot free-standing production riser system to the FPF. The produced fluids are partially separated on the FPF before oil and gas are pumped through the template to export gathering lines that are connected to the shallow water facility. The system designed through-put is 40,000 BOPD of oil and 120 MMSCFD of gas.« less

  6. Template-Based Modeling of Protein-RNA Interactions.

    PubMed

    Zheng, Jinfang; Kundrotas, Petras J; Vakser, Ilya A; Liu, Shiyong

    2016-09-01

    Protein-RNA complexes formed by specific recognition between RNA and RNA-binding proteins play an important role in biological processes. More than a thousand of such proteins in human are curated and many novel RNA-binding proteins are to be discovered. Due to limitations of experimental approaches, computational techniques are needed for characterization of protein-RNA interactions. Although much progress has been made, adequate methodologies reliably providing atomic resolution structural details are still lacking. Although protein-RNA free docking approaches proved to be useful, in general, the template-based approaches provide higher quality of predictions. Templates are key to building a high quality model. Sequence/structure relationships were studied based on a representative set of binary protein-RNA complexes from PDB. Several approaches were tested for pairwise target/template alignment. The analysis revealed a transition point between random and correct binding modes. The results showed that structural alignment is better than sequence alignment in identifying good templates, suitable for generating protein-RNA complexes close to the native structure, and outperforms free docking, successfully predicting complexes where the free docking fails, including cases of significant conformational change upon binding. A template-based protein-RNA interaction modeling protocol PRIME was developed and benchmarked on a representative set of complexes.

  7. Remote detection of weak aftershocks of the DPRK underground explosions using waveform cross correlation

    NASA Astrophysics Data System (ADS)

    Le Bras, R.; Rozhkov, M.; Bobrov, D.; Kitov, I. O.; Sanina, I.

    2017-12-01

    Association of weak seismic signals generated by low-magnitude aftershocks of the DPRK underground tests into event hypotheses represent a challenge for routine automatic and interactive processing at the International Data Centre (IDC) of the Comprehensive Nuclear-Test-Ban Treaty Organization, due to the relatively low station density of the International Monitoring System (IMS) seismic network. Since 2011, as an alternative, the IDC has been testing various prototype techniques of signal detection and event creation based on waveform cross correlation. Using signals measured by seismic stations of the IMS from DPRK explosions as waveform templates, the IDC detected several small (estimated mb between 2.2 and 3.6) seismic events after two DPRK tests conducted on September 9, 2016 and September 3, 2017. The obtained detections were associated with reliable event hypothesis and then used to locate these events relative to the epicenters of the DPRK explosions. We observe high similarity of the detected signals with the corresponding waveform templates. The newly found signals also correlate well between themselves. In addition, the values of the signal-to-noise ratios (SNR) estimated using the traces of cross correlation coefficients, increase with template length (from 5 s to 150 s), providing strong evidence in favour of their spatial closeness, which allows interpreting them as explosion aftershocks. We estimated the relative magnitudes of all aftershocks using the ratio of RMS amplitudes of the master and slave signal in the cross correlation windows characterized by the highest SNR. Additional waveform data from regional non-IMS stations MDJ and SEHB provide independent validation of these aftershock hypotheses. Since waveform templates from any single master event may be sub-efficient at some stations, we have also developed a method of joint usage of the DPRK and the biggest aftershocks templates to build more robust event hypotheses.

  8. Why Waveform Correlation Sometimes Fails

    NASA Astrophysics Data System (ADS)

    Carmichael, J.

    2015-12-01

    Waveform correlation detectors used in explosion monitoring scan noisy geophysical data to test two competing hypotheses: either (1) an amplitude-scaled version of a template waveform is present, or, (2) no signal is present at all. In reality, geophysical wavefields that are monitored for explosion signatures include waveforms produced by non-target sources that are partially correlated with the waveform template. Such signals can falsely trigger correlation detectors, particularly at low thresholds required to monitor for smaller target explosions. This challenge is particularly formidable when monitoring known test sites for seismic disturbances, since uncatalogued natural seismicity is (generally) more prevalent at lower magnitudes, and could be mistaken for small explosions. To address these challenges, we identify real examples in which correlation detectors targeting explosions falsely trigger on both site-proximal earthquakes (Figure 1, below) and microseismic "noise". Motivated by these examples, we quantify performance loss when applying these detectors, and re-evaluate the correlation-detector's hypothesis test. We thereby derive new detectors from more general hypotheses that admit unknown background seismicity, and apply these to real data. From our treatment, we derive "rules of thumb'' for proper template and threshold selection in heavily cluttered signal environments. Last, we answer the question "what is the probability of falsely detecting an earthquake collocated at a test site?", using correlation detectors that include explosion-triggered templates. Figure Top: An eight-channel data stream (black) recorded from an earthquake near a mine. Red markers indicate a detection. Middle: The correlation statistic computed by scanning the template against the data stream at top. The red line indicates the threshold for event declaration, determined by a false-alarm on noise probability constraint, as computed from the signal-absent distribution using the Neyman Pearson criteria. Bottom: The histogram of the correlation statistic time series (gray) superimposed on the theoretical null distribution (black curve). The line shows the threshold, consistent with a right-tail probability, computed from the black curve.

  9. Lightning Protection System for HE Facilities at LLNL - Certification Template

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clancy, T J; Ong, M M; Brown, C G

    2005-12-08

    This document is meant as a template to assist in the development of your own lighting certification process. Aside from this introduction and the mock representative name of the building (Building A), this document is nearly identical to a lightning certification report issued by the Engineering Directorate at Lawrence Livermore National Laboratory. At the date of this release, we have certified over 70 HE processing and storage cells at our Site 300 facilities. In Chapters 1 and 2 respectively, we address the need and methods of lightning certification for HE processing and storage facilities at LLNL. We present the preferredmore » method of lightning protection in Chapter 3, as well as the likely building modifications that are needed to comply with this method. In Chapter 4, we present the threat assessment and resulting safe work areas within a cell. After certification, there may be changes to operations during a lightning alert, and this is discussed in Chapter 5. Chapter 6 lists the maintenance requirements for the continuation of lighting certification status. Appendices of this document are meant as an aid in developing your own certification process, and they include a bonding list, an inventory of measurement equipment, surge suppressors in use at LLNL, an Integrated Work and Safety form (IWS), and a template certification sign-off sheet. The lightning certification process involves more that what is spelled out in this document. The first steps involve considerable planning, the securing of funds, and management and explosives safety buy-in. Permits must be obtained, measurement equipment must be assembled and tested, and engineers and technicians must be trained in their use. Cursory building inspections are also recommended, and surge suppression for power systems must be addressed. Upon completion of a certification report and its sign-off by management, additional work is required. Training will be needed in order to educate workers and facility managers of the requirements of lightning certification. Operating procedures will need to be generated and/or modified with additional controls. Engineering controls may also be implemented requiring the modification of cells. Careful planning should bring most of these issues to light, making it clear where this document is helpful and were additional assistance may be necessary.« less

  10. Mismodeling in gravitational-wave astronomy: The trouble with templates

    NASA Astrophysics Data System (ADS)

    Sampson, Laura; Cornish, Neil; Yunes, Nicolás

    2014-03-01

    Waveform templates are a powerful tool for extracting and characterizing gravitational wave signals, acting as highly restrictive priors on the signal morphologies that allow us to extract weak events buried deep in the instrumental noise. The templates map the waveform shapes to physical parameters, thus allowing us to produce posterior probability distributions for these parameters. However, there are attendant dangers in using highly restrictive signal priors. If strong field gravity is not accurately described by general relativity (GR), then using GR templates may result in fundamental bias in the recovered parameters, or even worse, a complete failure to detect signals. Here we study such dangers, concentrating on three distinct possibilities. First, we show that there exist modified theories compatible with all existing observations that would fail to be detected by the LIGO/Virgo network using searches based on GR templates, but which would be detected using a one parameter post-Einsteinian extension. Second, we study modified theories that produce departures from GR that turn on suddenly at a critical frequency, producing waveforms that do not directly fit into the simplest parametrized post-Einsteinian (ppE) scheme. We show that even the simplest ppE templates are still capable of picking up these strange signals and diagnosing a departure from GR. Third, we study whether using inspiral-only ppE waveforms for signals that include merger and ringdown can lead to problems in misidentifying a GR departure. We present a simple technique that allows us to self-consistently identify the inspiral portion of the signal, and thus remove these potential biases, allowing GR tests to be performed on higher mass signals that merge within the detector band. We close by studying a parametrized waveform model that may allow us to test GR using the full inspiral-merger-ringdown signal.

  11. Educational Utilization of Microsoft Powerpoint for Oral and Maxillofacial Cancer Presentations.

    PubMed

    Carvalho, Francisco Samuel Rodrigues; Chaves, Filipe Nobre; Soares, Eduardo Costa Studart; Pereira, Karuza Maria Alves; Ribeiro, Thyciana Rodrigues; Fonteles, Cristiane Sa Roriz; Costa, Fabio Wildson Gurgel

    2016-01-01

    Electronic presentations have become useful tools for surgeons, other clinicians and patients, facilitating medical and legal support and scientific research. Microsoft® PowerPoint is by far and away the most commonly used computer-based presentation package. Setting up surgical clinical cases with PowerPoint makes it easy to register and follow patients for the purpose of discussion of treatment plan or scientific presentations. It facilitates communication between professionals, supervising clinical cases and teaching. It is often useful to create a template to standardize the presentation, offered by the software through the slide master. The purpose of this paper was to show a simple and practical method for creating a Microsoft® PowerPoint template for use in presentations concerning oral and maxillofacial cancer.

  12. A default normal chest CT structured reporting field for coronary calcifications does not cause excessive false-negative reporting.

    PubMed

    Walter, William R; Goldberg-Stein, Shlomit; Levsky, Jeffrey M; Cohen, Hillel W; Scheinfeld, Meir H

    2015-08-01

    The aim of this study was to compare the accuracy of coronary atherosclerosis reporting before and after the implementation of a structured reporting chest CT template. A noncardiac, noncontrast chest CT structured reporting template was developed and mandated for department-wide use at a large academic center. The template included the statement "There are no coronary artery calcifications." All noncardiac, noncontrast chest CT examinations reported over 3 days, 1 month after template implementation (structured template group), and from a 3-day period 1 year prior (control group) were retrospectively collected. Final radiology reports were reviewed and designated positive or negative for coronary calcifications. CT images were reviewed in consensus by 2 radiologists, who scored each case for the presence or absence of coronary calcifications, blinded to the original report. Statistical analysis was performed using Pearson χ(2) and Fisher exact tests. Sixty-five percent (69 of 106) of structured template group and 58% (62 of 106) of control group cases had coronary calcifications. Reports from the structured template group were more likely to correctly state the presence or absence of coronary atherosclerosis compared with those from the control group (96.2% vs 85.8%; odds ratio, 4.2; 95% confidence interval, 1.3-13.1; P = .008). Structured template group reports were less likely to be falsely negative compared with control group reports (3.8% vs 11.7%; odds ratio, 3.4; 95% confidence interval, 1.0-10.8; P = .03). Implementing a structured reporting template improves reporting accuracy of coronary calcifications. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  13. The Impact of Template Types on Polyeugenol to the Adsorption Selectivity of Ionic Imprinted Polymer (IIP) Fe Metal Ion

    NASA Astrophysics Data System (ADS)

    Djunaidi, M. C.; Haris, A.; Pardoyo; Rosdiana, K.

    2018-04-01

    The synthesis of IIP was carried out by variation of Fe(III) ion templates from Fe(NO3)3, K3[Fe(CN)6] and NH4Fe(SO4)2 compounds which then tested IIP selectivity to the Fe metal ions through adsorption process. Ionic Imprinted Polymer (IIP) is a method of printing metal ions bound in a polymer, subsequently released from the polymer matrix to produce a suitable imprint for the target ion. The purposes of this study were to produce IIP from Fe(NO3)3, K3[Fe(CN)6] and NH4Fe(SO4)2 templates, to know the effect of templates on adsorption selectivity of IIP involving imprint cavity, and to know the impact of metal competitor on the selectivity adsorption of IIP to the Fe metals. The results obtained showed that IIP synthesized by variations of Fe(NO3)3, K3[Fe(CN)6] and NH4Fe(SO4)2 templates were successfully synthesized. The adsorption selectivity of Fe (III) metal ion in the Fe(NO3)3 template was greater than that of in the K3[Fe(CN)6] and NH4Fe(SO4)2 templates. The adsorption selectivity of Fe was greater on Fe-Cr compared to on Fe-Cd and Fe-Pb.

  14. Effects of polyamines and methylglyoxal bis(guanylhydrazone) on hepatic nuclear structure and deoxyribonucleic acid template activity.

    PubMed Central

    Brown, K B; Nelson, N F; Brown, D G

    1975-01-01

    1. The interaction of polyamines and methylglyoxal bis(guanythydrazone) (1, 1'-[(methylethanediylidene)-dinitrilo]diguanidine) with isolated rat liver nuclei was investigated by electron microscopy. 2. At 4mM, putrescine was without effect; however, spermidine, spermine or methylglyoxal bis(guanythydrazone) resulted in dispersed chromatin and alterations in nucleolar structure. In addition, spermidine or methylglyoxal bis(guanylhydrazone) caused marked aggregation of interchromatin granules. 3. The DNA template property of calf thymus DNA was examined by using DNA polymerases from Escherichia coli, Micrococcus lysodeikticus and calf thymus in the presence of 0-5 mM-amine. 4. In the presence of DNA polymerase, spermine or methylglyoxal bis(guanylhydrazone) inhibited activity, whereas putrescine or spermidine had much less effect or in some cases stimulated [3H]dTMP incorporation. 5. Template activity which was inhibited by spermine or methylglyoxal bis(guanylhydrazone) could be partially restored by additional DNA or enzyme. 6. When mixed with calf thymus DNA, calf thymus histone inhibited template activity as measured with E. coli DNA polymerase. The template activity of such a 'histone-nucleate' could not be restored by putrescine, spermidine, spermine or methylglyoxal bis(guanylhydrazone). 7. DNA template activity of isolated rat liver nuclei was tested by using E. coli DNA polymerase. None of the amines was able to increase the template activity of the nuclear DNA in vitro. Images PLATE 1 PMID:1218090

  15. Effects of polyamines and methylglyoxal bis(guanylhydrazone) on hepatic nuclear structure and deoxyribonucleic acid template activity.

    PubMed

    Brown, K B; Nelson, N F; Brown, D G

    1975-12-01

    1. The interaction of polyamines and methylglyoxal bis(guanythydrazone) (1, 1'-[(methylethanediylidene)-dinitrilo]diguanidine) with isolated rat liver nuclei was investigated by electron microscopy. 2. At 4mM, putrescine was without effect; however, spermidine, spermine or methylglyoxal bis(guanythydrazone) resulted in dispersed chromatin and alterations in nucleolar structure. In addition, spermidine or methylglyoxal bis(guanylhydrazone) caused marked aggregation of interchromatin granules. 3. The DNA template property of calf thymus DNA was examined by using DNA polymerases from Escherichia coli, Micrococcus lysodeikticus and calf thymus in the presence of 0-5 mM-amine. 4. In the presence of DNA polymerase, spermine or methylglyoxal bis(guanylhydrazone) inhibited activity, whereas putrescine or spermidine had much less effect or in some cases stimulated [3H]dTMP incorporation. 5. Template activity which was inhibited by spermine or methylglyoxal bis(guanylhydrazone) could be partially restored by additional DNA or enzyme. 6. When mixed with calf thymus DNA, calf thymus histone inhibited template activity as measured with E. coli DNA polymerase. The template activity of such a 'histone-nucleate' could not be restored by putrescine, spermidine, spermine or methylglyoxal bis(guanylhydrazone). 7. DNA template activity of isolated rat liver nuclei was tested by using E. coli DNA polymerase. None of the amines was able to increase the template activity of the nuclear DNA in vitro.

  16. Developing and Implementing a Citywide Asthma Action Plan: A Community Collaborative Partnership.

    PubMed

    Staudt, Amanda Marie; Alamgir, Hasanat; Long, Debra Lynn; Inscore, Stephen Curtis; Wood, Pamela Runge

    2015-12-01

    Asthma affects 1 in 10 children in the United States, with higher prevalence among children living in poverty. Organizations in San Antonio, Texas, partnered to design and implement a uniform, citywide asthma action plan to improve asthma management capacity in schools. The asthma action plan template was modified from that of the Global Initiative for Asthma. School personnel were trained in symptom recognition, actions to take, and use of equipment before the asthma action plan implementation. The annual Asthma Action Plan Summit was organized as a forum for school nurses, healthcare providers, and members of the community to exchange ideas and strategies on implementation, as well as to revise the plan. The asthma action plan was implemented in all 16 local school districts. Feedback received from school nurses suggests that the citywide asthma action plan resulted in improved asthma management and student health at schools. The evidence in this study suggests that community organizations can successfully collaborate to implement a citywide health initiative similar to the asthma action plan.

  17. Template for updating regulations in QA manuals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White, M.G.; Banerjee, B.

    1992-01-01

    Recently, the U.S. Department of Energy (DOE) issued new quality assurance (QA) orders to reflect current policies for conduct and operation of DOE-authorized programs and facilities. Establishing traceability to new QA criteria and requirements from former multidraft orders, QA manuals, and guidance documentation for DOE-funded work can be confusing. Identified critical considerations still must be addressed. Most of the newly stated QA criteria can be cross referenced, where applicable, to former QA plans and manuals. Where additional criteria occur, new procedures may be required, together with revisions in QA plans and manuals.

  18. Preparing strategic information management plans for hospitals: a practical guideline SIM plans for hospitals: a guideline.

    PubMed

    Brigl, B; Ammenwerth, E; Dujat, C; Gräber, S; Grosse, A; Häber, A; Jostes, C; Winter, A

    2005-01-01

    Systematic information management in hospitals demands for a strategic information management plan (SIM plan). As preparing a SIM plan is a considerable challenge we provide a practical guideline that is directly applicable when a SIM plan is going to be prepared. The guideline recommends a detailed structure of a SIM plan and gives advice about its content and the preparation process. It may be used as template, which can be adapted to the individual demands of any hospital. The guideline was used in several hospitals preparing a SIM plan. Experiences showed that the SIM plans could be prepared very efficiently and timely using the guideline, that the proposed SIM plan structure suited well, that the guideline offers enough flexibility to meet the requirements of the individual hospitals and that the specific recommendations of the guideline were very helpful. Nevertheless, we must strive for a more comprehensive theory of strategic information management planning which -- in the sense of enterprise architecture planning -- represents the intrinsic correlations of the different parts of a SIM plan to a greater extent.

  19. Rubber stamp templates for improving clinical documentation: A paper-based, m-Health approach for quality improvement in low-resource settings.

    PubMed

    Kleczka, Bernadette; Musiega, Anita; Rabut, Grace; Wekesa, Phoebe; Mwaniki, Paul; Marx, Michael; Kumar, Pratap

    2018-06-01

    The United Nations' Sustainable Development Goal #3.8 targets 'access to quality essential healthcare services'. Clinical practice guidelines are an important tool for ensuring quality of clinical care, but many challenges prevent their use in low-resource settings. Monitoring the use of guidelines relies on cumbersome clinical audits of paper records, and electronic systems face financial and other limitations. Here we describe a unique approach to generating digital data from paper using guideline-based templates, rubber stamps and mobile phones. The Guidelines Adherence in Slums Project targeted ten private sector primary healthcare clinics serving informal settlements in Nairobi, Kenya. Each clinic was provided with rubber stamp templates to support documentation and management of commonly encountered outpatient conditions. Participatory design methods were used to customize templates to the workflows and infrastructure of each clinic. Rubber stamps were used to print templates into paper charts, providing clinicians with checklists for use during consultations. Templates used bubble format data entry, which could be digitized from images taken on mobile phones. Besides rubber stamp templates, the intervention included booklets of guideline compilations, one Android phone for digitizing images of templates, and one data feedback/continuing medical education session per clinic each month. In this paper we focus on the effect of the intervention on documentation of three non-communicable diseases in one clinic. Seventy charts of patients enrolled in the chronic disease program (hypertension/diabetes, n=867; chronic respiratory diseases, n=223) at one of the ten intervention clinics were sampled. Documentation of each individual patient encounter in the pre-intervention (January-March 2016) and post-intervention period (May-July) was scored for information in four dimensions - general data, patient assessment, testing, and management. Control criteria included information with no counterparts in templates (e.g. notes on presenting complaints, vital signs). Documentation scores for each patient were compared between both pre- and post-intervention periods and between encounters documented with and without templates (post-intervention only). The total number of patient encounters in the pre-intervention (282) and post-intervention periods (264) did not differ. Mean documentation scores increased significantly in the post-intervention period on average by 21%, 24% and 17% for hypertension, diabetes and chronic respiratory diseases, respectively. Differences were greater (47%, 43% and 27%, respectively) when documentation with and without templates was compared. Changes between pre- vs.post-intervention, and with vs.without template, varied between individual dimensions of documentation. Overall, documentation improved more for general data and patient assessment than in testing or management. The use of templates improves paper-based documentation of patient care, a first step towards improving the quality of care. Rubber stamps provide a simple and low-cost method to print templates on demand. In combination with ubiquitously available mobile phones, information entered on paper can be easily and rapidly digitized. This 'frugal innovation' in m-Health can empower small, private sector facilities, where large numbers of urban patients seek healthcare, to generate digital data on routine outpatient care. These data can form the basis for evidence-based quality improvement efforts at large scale, and help deliver on the SDG promise of quality essential healthcare services for all. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Transition and closeout of the Fernald Closure Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bilson, H.E.; Terry, T.; Reising, J.

    The U.S. Department of Energy (DOE) and Fluor Fernald have completed the majority of the cleanup of the Fernald Site. The over 1,000 acre complex for processing uranium has been demolished and soil contamination has been remediated. With acres of wetlands and prairies replacing the buildings and waste pits. At the end of the project the focus shifted to developing demonstrating the completion of the project and the contract, as well as ensuring a smooth transition of the facility from the DOE's Environmental Management (EM) Program to the DOE's Legacy Management (LM) Program. Working with the DOE, each portion ofmore » the closure contract was examined for specific closure definition. From this negotiation effort the Comprehensive Exit and Transition Plan (CE/T Plan) was written. The CE/T Plan is intended to assist DOE in the analysis that the site is ready for transfer into long-term stewardship (LTS) (also referred to as legacy management) and that Fluor Fernald, Inc. has satisfactorily completed the closure contract statement of work elements. Following the Lessons Learned from the closure of the Rocky Flats Site, the DOE's Legacy Management Program created a matrix of Transition Elements required to ensure adequate information was in place to allow the new prime contractor to perform the Legacy Management scope of work. The transition plan included over 1,000 elements broken down into functional areas and relied on specific Fernald Responsibility Transition Packages (RTPs) for detailed transition actions. The template for Closure and Transition Planning used at the Fernald Site was developed using the best Lessons Learned from across the DOE Complex. The template could be used for other sites, and lessons learned from this closure and transition will be appropriate for all closure projects. (authors)« less

  1. Guided Endodontics: a novel treatment approach for teeth with pulp canal calcification and apical pathology.

    PubMed

    Krastl, Gabriel; Zehnder, Marc S; Connert, Thomas; Weiger, Roland; Kühl, Sebastian

    2016-06-01

    To present a new treatment approach for teeth with pulp canal calcification (PCC) which require root canal treatment. A 15-year-old male patient presented with pain of his upper right central incisor. The tooth showed signs of apical periodontitis. Due to PCC, location of the root canal was judged to be difficult and associated with a high risk of perforation. A cone beam computed tomography (CBCT) and an intra-oral surface scan were performed and matched using software for virtual implant planning. After planning the position of the drill for root canal location, a virtual template was designed, and the data were exported as an STL file and sent to a 3D printer for template fabrication. The template was positioned on the anterior maxillary teeth. A specific drill was used to penetrate through the obliterated part of the root canal and obtain minimally invasive access to the apical part. The root canal was accessible at 9 mm distance from the apex. Further root canal preparation was carried out using an endodontic rotary instrumentation system. After an interappointment dressing for 4 weeks, the root canal was filled with vertically condensed gutta-percha using an epoxy sealer. The access cavity was restored with a composite material. After 15 months, the patient was clinically asymptomatic with no pain on percussion. The radiograph showed no apical pathology. The presented guided endodontic approach seems to be a safe, clinically feasible method to locate root canals and prevent root perforation in teeth with PCC. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Using Fluvial Geomorphology as a Physical Template in Process-Based and Recovery Enhancement Approaches to River Management

    NASA Astrophysics Data System (ADS)

    Fryirs, K.

    2016-12-01

    In an `era of river repair' fluvial geomorphology has emerged as a key science in river management practice. Geomorphologists are ideally placed to use their science in an applied manner to provide guidance on the impact of floods and droughts, landuse and climate change, and water use on river forms, processes and evolution. Increasingly, fluvial geomorphologists are also asked to make forecasts about how systems might adjust in the future, and to work with managers to implement strategies on-the-ground. Using case study material from Eastern Australia (Bega, Hunter, Wollombi and Lockyer catchments) I will focus on how process-based understanding of rivers has developed and evolved to provide a coherent physical template for effective and proactive, river management practice. I will focus on four key principles and demonstrate how geomorphology has been, and should continue to be, used in process-based, recovery enhancement approaches to river management. How understanding the difference between river behaviour and river change is used to determine how a river is `expected' to function, and how to identify anomalous processes requiring a treatment response. How understanding evolutionary trajectory is used to make future forecasts on river condition and recovery potential, and how working with processes can enhance river recovery. How geomorphic information can be used as a physical template atop which to analyse a range of biotic processes and habitat outcomes. How geomorphic information is used to effectively prioritise and plan river conservation and rehabilitation activities as part of catchment and region-scale action plans.

  3. A medium invasiveness multi-level patient's specific template for pedicle screw placement in the scoliosis surgery.

    PubMed

    Azimifar, Farhad; Hassani, Kamran; Saveh, Amir Hossein; Ghomsheh, Farhad Tabatabai

    2017-11-14

    Several methods including free-hand technique, fluoroscopic guidance, image-guided navigation, computer-assisted surgery system, robotic platform and patient's specific templates are being used for pedicle screw placement. These methods have screw misplacements and are not always easy to be applied. Furthermore, it is necessary to expose completely a large portions of the spine in order to access fit entirely around the vertebrae. In this study, a multi-level patient's specific template with medium invasiveness was proposed for pedicle screw placement in the scoliosis surgery. It helps to solve the problems related to the soft tissues removal. After a computer tomography (CT) scan of the spine, the templates were designed based on surgical considerations. Each template was manufactured using three-dimensional printing technology under a semi-flexible post processing. The templates were placed on vertebras at four points-at the base of the superior-inferior articular processes on both left-right sides. This helps to obtain less invasive and more accurate procedure as well as true-stable and easy placement in a unique position. The accuracy of screw positions was confirmed by CT scan after screw placement. The result showed the correct alignment in pedicle screw placement. In addition, the template has been initially tested on a metal wire series Moulage (height 70 cm and material is PVC). The results demonstrated that it could be possible to implement it on a real patient. The proposed template significantly reduced screw misplacements, increased stability, and decreased the sliding & the intervention invasiveness.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Campbell, W; Miften, M; Jones, B

    Purpose: Pancreatic SBRT relies on extremely accurate delivery of ablative radiation doses to the target, and intra-fractional tracking of fiducial markers can facilitate improvements in dose delivery. However, this requires algorithms that are able to find fiducial markers with high speed and accuracy. The purpose of this study was to develop a novel marker tracking algorithm that is robust against many of the common errors seen with traditional template matching techniques. Methods: Using CBCT projection images, a method was developed to create detailed template images of fiducial marker clusters without prior knowledge of the number of markers, their positions, ormore » their orientations. Briefly, the method (i) enhances markers in projection images, (ii) stabilizes the cluster’s position, (iii) reconstructs the cluster in 3D, and (iv) precomputes a set of static template images dependent on gantry angle. Furthermore, breathing data were used to produce 4D reconstructions of clusters, yielding dynamic template images dependent on gantry angle and breathing amplitude. To test these two approaches, static and dynamic templates were used to track the motion of marker clusters in more than 66,000 projection images from 75 CBCT scans of 15 pancreatic SBRT patients. Results: For both static and dynamic templates, the new technique was able to locate marker clusters present in projection images 100% of the time. The algorithm was also able to correctly locate markers in several instances where only some of the markers were visible due to insufficient field-of-view. In cases where clusters exhibited deformation and/or rotation during breathing, dynamic templates resulted in cross-correlation scores up to 70% higher than static templates. Conclusion: Patient-specific templates provided complete tracking of fiducial marker clusters in CBCT scans, and dynamic templates helped to provide higher cross-correlation scores for deforming/rotating clusters. This novel algorithm provides an extremely accurate method to detect fiducial markers during treatment. Research funding provided by Varian Medical Systems to Miften and Jones.« less

  5. Distinctive Capillary Action by Micro-channels in Bone-like Templates can Enhance Recruitment of Cells for Restoration of Large Bony Defect.

    PubMed

    Oh, Daniel S; Koch, Alia; Eisig, Sidney; Kim, Sahng Gyoon; Kim, Yoon Hyuk; Kim, Do-Gyoon; Shim, Jae Hyuck

    2015-09-11

    Without an active, thriving cell population that is well-distributed and stably anchored to the inserted template, exceptional bone regeneration does not occur. With conventional templates, the absence of internal micro-channels results in the lack of cell infiltration, distribution, and inhabitance deep inside the templates. Hence, a highly porous and uniformly interconnected trabecular-bone-like template with micro-channels (biogenic microenvironment template; BMT) has been developed to address these obstacles. The novel BMT was created by innovative concepts (capillary action) and fabricated with a sponge-template coating technique. The BMT consists of several structural components: inter-connected primary-pores (300-400 µm) that mimic pores in trabecular bone, micro-channels (25-70 µm) within each trabecula, and nanopores (100-400 nm) on the surface to allow cells to anchor. Moreover, the BMT has been documented by mechanical test study to have similar mechanical strength properties to those of human trabecular bone (~3.8 MPa)12. The BMT exhibited high absorption, retention, and habitation of cells throughout the bridge-shaped (Π) templates (3 cm height and 4 cm length). The cells that were initially seeded into one end of the templates immediately mobilized to the other end (10 cm distance) by capillary action of the BMT on the cell media. After 4 hr, the cells homogenously occupied the entire BMT and exhibited normal cellular behavior. The capillary action accounted for the infiltration of the cells suspended in the media and the distribution (active migration) throughout the BMT. Having observed these capabilities of the BMT, we project that BMTs will absorb bone marrow cells, growth factors, and nutrients from the periphery under physiological conditions. The BMT may resolve current limitations via rapid infiltration, homogenous distribution and inhabitance of cells in large, volumetric templates to repair massive skeletal defects.

  6. Summer Reading Camp Self-Study Guide. REL 2015-070

    ERIC Educational Resources Information Center

    Smith, Kevin G.; Foorman, Barbara R.

    2015-01-01

    This guide is designed to facilitate self-studies of planning and implementation of state-required summer reading camp programs for grade 3 students who scored at the lowest level on the state reading assessment. It provides a template for data collection and guiding questions for discussion that may improve instruction and increase the number of…

  7. Delivering Speech and Language Therapy to Head Start Children: A Template for Inclusion through Systemic Change.

    ERIC Educational Resources Information Center

    Strobridge, Michele

    This practicum was designed to provide speech and language therapy to children identified as speech and language impaired, in a Head Start classroom with typically developing peers. The practicum involved amending Head Start component plans, discussing inclusion issues at four education component meetings, conducting an interagency meeting with…

  8. Relative Packing Groups in Template-Based Structure Prediction: Cooperative Effects of True Positive Constraints

    PubMed Central

    Day, Ryan; Qu, Xiaotao; Swanson, Rosemarie; Bohannan, Zach; Bliss, Robert

    2011-01-01

    Abstract Most current template-based structure prediction methods concentrate on finding the correct backbone conformation and then packing sidechains within that backbone. Our packing-based method derives distance constraints from conserved relative packing groups (RPGs). In our refinement approach, the RPGs provide a level of resolution that restrains global topology while allowing conformational sampling. In this study, we test our template-based structure prediction method using 51 prediction units from CASP7 experiments. RPG-based constraints are able to substantially improve approximately two-thirds of starting templates. Upon deeper investigation, we find that true positive spatial constraints, especially those non-local in sequence, derived from the RPGs were important to building nearer native models. Surprisingly, the fraction of incorrect or false positive constraints does not strongly influence the quality of the final candidate. This result indicates that our RPG-based true positive constraints sample the self-consistent, cooperative interactions of the native structure. The lack of such reinforcing cooperativity explains the weaker effect of false positive constraints. Generally, these findings are encouraging indications that RPGs will improve template-based structure prediction. PMID:21210729

  9. Multiview human activity recognition system based on spatiotemporal template for video surveillance system

    NASA Astrophysics Data System (ADS)

    Kushwaha, Alok Kumar Singh; Srivastava, Rajeev

    2015-09-01

    An efficient view invariant framework for the recognition of human activities from an input video sequence is presented. The proposed framework is composed of three consecutive modules: (i) detect and locate people by background subtraction, (ii) view invariant spatiotemporal template creation for different activities, (iii) and finally, template matching is performed for view invariant activity recognition. The foreground objects present in a scene are extracted using change detection and background modeling. The view invariant templates are constructed using the motion history images and object shape information for different human activities in a video sequence. For matching the spatiotemporal templates for various activities, the moment invariants and Mahalanobis distance are used. The proposed approach is tested successfully on our own viewpoint dataset, KTH action recognition dataset, i3DPost multiview dataset, MSR viewpoint action dataset, VideoWeb multiview dataset, and WVU multiview human action recognition dataset. From the experimental results and analysis over the chosen datasets, it is observed that the proposed framework is robust, flexible, and efficient with respect to multiple views activity recognition, scale, and phase variations.

  10. Application of a 3-dimensional printed navigation template in Bernese periacetabular osteotomies: A cadaveric study.

    PubMed

    Zhou, You; Kang, Xiaopeng; Li, Chuan; Xu, Xiaoshan; Li, Rong; Wang, Jun; Li, Wei; Luo, Haotian; Lu, Sheng

    2016-12-01

    The aim of the present study was to describe the application of 3D printed templates for intraoperative navigation and simulation of periacetabular osteotomies (PAOs) in a cadaveric model.Five cadaveric specimens (10 sides) underwent thin-slice computed tomographic scans of the ala of ilium downwards to the proximal end of femoral shaft. Bernese PAO was performed. Using Mimics v10.1 software (Materialise, Leuven, Belgium), 3D computed tomographic reconstructions were created and the 4 standard PAO bone cuts-ischial, pubic, anterior, and posterior aspects of the ilium-as well as rotation of the dislocated acetabular bone blocks were simulated for each specimen. Using these data, custom 3D printed bone-drilling templates of the pelvis were manufactured, to guide surgical placement of the PAO bone cuts. An angle fix wedge was designed and printed, to help accurately achieve the predetermined rotation angle of the acetabular bone block. Each specimen underwent a conventional PAO. Preoperative, postsimulation, and postoperative lateral center-edge angles, acetabular indices, extrusion indices, and femoral head coverage were measured and compared; P and t values were calculated for above-mentioned measurements while comparing preoperative and postoperative data, and also in postsimulation and postoperative data comparison.All 10 PAO osteotomies were successfully completed using the 3D printed bone-drilling template and angle fix wedge. No osteotomy entered the hip joint and a single posterior column fracture was observed. Comparison of preoperative and postoperative measurements of the 10 sides showed statistically significant changes, whereas no statistically significant differences between postsimulation and postoperative values were noted, demonstrating the accuracy and utility of the 3D printed templates.The application of patient-specific 3D printed bone-drilling and rotation templates in PAO is feasible and may facilitate improved clinical outcomes, through the use of precise presurgical planning and reduced surgical complications with the precisely guided bone drilling.

  11. Y2K compliance readiness and contingency planning.

    PubMed

    Stahl, S; Cohan, D

    1999-09-01

    As the millennium approaches, discussion of "Y2K compliance" will shift to discussion of "Y2K readiness." While "compliance" focuses on the technological functioning of one's own computers, "readiness" focuses on the operational planning required in a world of interdependence, in which the functionality of one's own computers is only part of the story. "Readiness" includes the ability to cope with potential Y2K failures of vendors, suppliers, staff, banks, utility companies, and others. Administrators must apply their traditional skills of analysis, inquiry and diligence to the manifold imaginable challenges which Y2K will thrust upon their facilities. The SPICE template can be used as a systematic tool to guide planning for this historic event.

  12. Template-Based Modeling of Protein-RNA Interactions

    PubMed Central

    Zheng, Jinfang; Kundrotas, Petras J.; Vakser, Ilya A.

    2016-01-01

    Protein-RNA complexes formed by specific recognition between RNA and RNA-binding proteins play an important role in biological processes. More than a thousand of such proteins in human are curated and many novel RNA-binding proteins are to be discovered. Due to limitations of experimental approaches, computational techniques are needed for characterization of protein-RNA interactions. Although much progress has been made, adequate methodologies reliably providing atomic resolution structural details are still lacking. Although protein-RNA free docking approaches proved to be useful, in general, the template-based approaches provide higher quality of predictions. Templates are key to building a high quality model. Sequence/structure relationships were studied based on a representative set of binary protein-RNA complexes from PDB. Several approaches were tested for pairwise target/template alignment. The analysis revealed a transition point between random and correct binding modes. The results showed that structural alignment is better than sequence alignment in identifying good templates, suitable for generating protein-RNA complexes close to the native structure, and outperforms free docking, successfully predicting complexes where the free docking fails, including cases of significant conformational change upon binding. A template-based protein-RNA interaction modeling protocol PRIME was developed and benchmarked on a representative set of complexes. PMID:27662342

  13. Clinical application of stereolithographic surgical guide with a handpiece guidance apparatus: a case report.

    PubMed

    Ozan, Oguz; Seker, Emre; Kurtulmus-Yilmaz, Sevcan; Ersoy, Ahmet Ersan

    2012-10-01

    The success of implant-supported restorations depends on the treatment planning and the transfer of planning through the surgical field. Recently, new computer-aided design and manufacturing (CAD/CAM) techniques, such as stereolithographic (SLA) rapid prototyping, have been developed to fabricate surgical guides to improve the precision of implant placement. The objective of the present case is to introduce a recently developed SLA surgical guide system into the rehabilitation of a 62-year-old male patient with mandibular edentulism. After obtaining a cone-beam computerized tomography (CBCT) scan of the mandible with a radiographic template, the images were transferred into a 3-dimensional (3D) image-based software for implant planning. The StentCad Beyond SLA surgical guide system, which is a combination of a currently used surgical template with pilot hollows and a surgical handpiece guidance apparatus, was designed to transfer a preoperatively defined implant position onto the surgical site without any drill-surgical guide contact. For the fabrication of this system, a surgical handpiece was scanned by a laser optical scanner and a mucosa-supported surgical guide was designed according to the patient's 3D model, which was attained from the CBCT images. Four dental implants were inserted through the SLA surgical guide system by a torque-controlled surgical handpiece to the interforaminal region via a flapless surgical procedure. Implants were assessed 3 months after surgery, and an implant-retained mandibular overdenture was fabricated. The present case emphasizes that CAD/CAM SLA surgical guides, along with CBCT images and scanning data, may help clinicians plan and place dental implants.

  14. An Investigation into the Trueness and Precision of Copy Denture Templates Produced by Rapid Prototyping and Conventional Means.

    PubMed

    Davda, K; Osnes, C; Dillon, S; Wu, J; Hyde, P; Keeling, A

    2017-12-01

    To assess the trueness and precision of copy denture templates produced using traditional methods and 3D printing. Six copies of a denture were made using: 1. Conventional technique with silicone putty in an impression tray (CT). 2. Conventional technique with no impression tray (CNT). 3. 3D scanning and printing (3D). Scan trueness and precision was investigated by scanning a denture six times and comparing five scans to the sixth. Then the scans of the six CT, CNT and 3D dentures were compared by aligning, in turn, the copies of each denture to the scanned original. Outcome measures were the mean surface-to-surface distance, standard deviation of that distance and the maximum distance. Student's unpaired t-tests with Bonferroni correction were used to analyse the results. The repeated scans of the original denture showed a scan trueness of 0.013mm (SD 0.002) and precision of 0.013mm (SD 0.002). Trueness: CT templates, 0.168mm (0.047), CNT templates 0.195mm (0.034) and 3D 0.103mm (0.021). Precision: CT templates 0.158mm (0.037), CNT 0.233mm (0.073), 3D 0.090mm (0.017). For each outcome measure the 3D templates demonstrated an improvement which was statistically significant (p⟨0.05). 3D printed copy denture templates reproduced the original with greater trueness and precision than conventional techniques. Copyright© 2017 Dennis Barber Ltd.

  15. Sea urchin skeleton: Structure, composition, and application as a template for biomimetic materials

    NASA Astrophysics Data System (ADS)

    Shapkin, Nikolay P.; Khalchenko, Irina G.; Panasenko, Alexander E.; Drozdov, Anatoly L.

    2017-07-01

    SEM and optical microscopy, chemical and EDX analysis, XRD, and FT-IR spectroscopy of three sea urchins skeletons (tests) show that the test is a spongy stereom, consisting of calcite with high content of magnesium. The tests are composed of mineral-organic composite of calcite-magnesite crystals, coated with organic film, containing silicon in form of polyphenylsiloxane. In the test of sea urchin pore spaces are linked into united system of regular structure with structure motive period about 20 um. This developed three-dimensional structure was used as a template for polymer material based on polyferrofenilsiloxane [OSiC6H5OH]x[OSiC6H5O]y[OFeO]z, which is chemically similar to the native film, coating sea urchins skeleton.

  16. Surgical Template to Minimize the Damage of Tooth Buds in Young Children With Mandibular Distraction Osteogenesis.

    PubMed

    Wang, Chenglong; Chen, Ying; You, Yuanrong; Wang, Meng; Lv, Changsheng; Gui, Lai

    2016-10-01

    Mandibular distraction osteogenesis has become one of the most powerful reconstructive techniques for the treatment of mandibular deformities in young children. Damage to the tooth buds is often cited as a complication of it. The purpose of this study was to precisely design the osteotomy line and avoid the damage of tooth buds at the mandibular angle area with the help of surgical template. Six patients aged from 6 to 10 years were selected in this study. Three-dimensional computed tomography data was put into Mimics software for preoperative planning the osteotomy line and the accurate placement of the distractor based on the exact position of tooth follicle. And then the surgical template was manufactured by a three-dimensional printer with rapid prototyping technique. The surgeons were guided to perform the osteotomy aided with the prefabricated template through an intraoral approach. Distraction began 7 days postoperation with a rate of 1 mm/d and the distractor was removed after a 6 to 8 months consolidation period. The tooth buds were observed through radiographs that were performed at 5 time intervals: before distraction, at the end of latency, at the end of distraction, at the end of consolidation and 2 years of the postoperation to remove the distractor. The average follow-up time is 24 months. Facial appearance and occlusal plane of all the young patients were greatly improved without complications. From the radiological observation, the tooth buds was intact after the surgery and the second molar normally erupted after removing the distractor. The surgical template was considered to be helpful in improving the surgical accuracy and avoiding the tooth buds damage during mandibular distraction osteogenesis.

  17. Spatial inhomogeneities in Al x Ga1-x N quantum wells induced by the surface morphology of AlN/sapphire templates

    NASA Astrophysics Data System (ADS)

    Zeimer, Ute; Jeschke, Joerg; Mogilatenko, Anna; Knauer, Arne; Kueller, Viola; Hoffmann, Veit; Kuhn, Christian; Simoneit, Tino; Martens, Martin; Wernicke, Tim; Kneissl, Michael; Weyers, Markus

    2015-11-01

    The effects of the template on the optical and structural properties of Al0.75Ga0.25N/Al0.8Ga0.2N multiple quantum well (MQWs) laser active regions have been investigated. The laser structures for optical pumping were grown on planar c-plane AlN/sapphire as well as on thick epitaxially laterally overgrown (ELO) AlN layers on patterned AlN/sapphire. Two ELO AlN/sapphire templates were investigated, one with a miscut of the sapphire surface to the m-direction with an angle of 0.25°, the other with a miscut angle of 0.25° to the sapphire a-direction. The MQWs are studied by atomic force microscopy, plan-view cathodoluminescence (CL) at room temperature and 83 K as well as transmission electron microscopy using high-angle annular dark-field imaging and energy-dispersive x-ray spectroscopy. The results are compared to optical pumping measurements. It was found that the surface morphology of the templates determines the lateral wavelength distribution in the MQWs observed by spectral CL mappings. The lateral wavelength spread is largest for the laser structures grown on ELO AlN with miscut to sapphire a-direction caused by the local variation of the MQW thicknesses and the Ga incorporation at macrosteps on the ELO-AlN. A CL peak wavelength spread of up to 7 nm has been found. The MQWs grown on planar AlN/sapphire templates show a homogeneous wavelength distribution. However, due to the high threading dislocation density and the resulting strong nonradiative recombination, laser operation could not be achieved. The laser structures grown on ELO AlN/sapphire show optically pumped lasing with a record short wavelength of 237 nm.

  18. Virtual Surgical Planning in Precise Maxillary Reconstruction With Vascularized Fibular Graft After Tumor Ablation.

    PubMed

    Wang, You-Yuan; Fan, Song; Zhang, Han-Qing; Lin, Zhao-Yu; Ye, Jian-Tao; Li, Jin-Song

    2016-06-01

    Reconstruction of maxillary and midfacial defects due to tumor ablation is challenging to conventional operation. The purposes of this study are to evaluate the precise 3-dimensional position of the fibular flap in reconstruction of maxillary defects assisted by virtual surgical planning and to assess the postoperative outcomes compared with conventional surgery. We retrospectively reviewed 18 consecutive patients who underwent maxillary reconstruction with a vascularized fibular flap assisted by virtual surgical planning after maxillary or midfacial tumor ablation. Conventional surgery was performed in another 15 patients. Proplan CMF surgical planning (Materialise, Leuven, Belgium) was performed preoperatively in the virtual planning group. Fibular flaps were harvested and underwent osteotomy assisted by prefabricated cutting guides, and the maxilla and midface were resected and reconstructed assisted by the prefabricated cutting guides and templates in the virtual planning group. The operative time and fibular flap positions were evaluated in the 2 groups. Postoperative fibular positions of the maxillary reconstruction were compared with virtual plans in the virtual planning group. The postoperative facial appearance and occlusal function were assessed. The operations were performed successfully without complications. The ischemia time and total operative time were shorter in the virtual planning group than those in the conventional surgery group (P < .05). High precision of the cutting guides and templates was found on both the fibula and maxilla in the virtual planning group. The positions of the fibular flaps, including the vertical and horizontal positions, were more accurate in the virtual planning group than those in the conventional surgery group (P < .05). Bone-to-bone contact between the maxilla and fibular segments was more precise in the virtual planning group (P < .05). Postoperative computed tomography scans showed excellent contour of the fibular flap segments in accordance with the virtual plans in the virtual planning group. All patients were alive with no evidence of disease. Functional mandibular range of motion, good occlusion, and an ideal facial appearance were observed in the virtual planning group. Virtual surgical planning appears to achieve precise maxillary reconstruction with a vascularized fibular flap after tumor ablation, as well as an ideal facial appearance and function after dental rehabilitation. The use of prefabricated cutting guides and plates eases fibular flap molding and placement, minimizes operating time, and improves clinical outcomes. Copyright © 2016 The American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  19. A waveform detector that targets template–decorrelated signals and achieves its predicted performance, Part I: Demonstration with IMS data

    DOE PAGES

    Carmichael, Joshua Daniel

    2016-01-01

    Here, waveform correlation detectors used in seismic monitoring scan multichannel data to test two competing hypotheses: that data contain (1) a noisy, amplitude-scaled version of a template waveform, or, (2) only noise. In reality, seismic wavefields include signals triggered by non-target sources (background seismicity) and targets signals that are only partially correlated with the waveform template.

  20. Refinement of protein termini in template-based modeling using conformational space annealing.

    PubMed

    Park, Hahnbeom; Ko, Junsu; Joo, Keehyoung; Lee, Julian; Seok, Chaok; Lee, Jooyoung

    2011-09-01

    The rapid increase in the number of experimentally determined protein structures in recent years enables us to obtain more reliable protein tertiary structure models than ever by template-based modeling. However, refinement of template-based models beyond the limit available from the best templates is still needed for understanding protein function in atomic detail. In this work, we develop a new method for protein terminus modeling that can be applied to refinement of models with unreliable terminus structures. The energy function for terminus modeling consists of both physics-based and knowledge-based potential terms with carefully optimized relative weights. Effective sampling of both the framework and terminus is performed using the conformational space annealing technique. This method has been tested on a set of termini derived from a nonredundant structure database and two sets of termini from the CASP8 targets. The performance of the terminus modeling method is significantly improved over our previous method that does not employ terminus refinement. It is also comparable or superior to the best server methods tested in CASP8. The success of the current approach suggests that similar strategy may be applied to other types of refinement problems such as loop modeling or secondary structure rearrangement. Copyright © 2011 Wiley-Liss, Inc.

  1. New template family for the detection of gravitational waves from comparable-mass black hole binaries

    NASA Astrophysics Data System (ADS)

    Porter, Edward K.

    2007-11-01

    In order to improve the phasing of the comparable-mass waveform as we approach the last stable orbit for a system, various resummation methods have been used to improve the standard post-Newtonian waveforms. In this work we present a new family of templates for the detection of gravitational waves from the inspiral of two comparable-mass black hole binaries. These new adiabatic templates are based on reexpressing the derivative of the binding energy and the gravitational wave flux functions in terms of shifted Chebyshev polynomials. The Chebyshev polynomials are a useful tool in numerical methods as they display the fastest convergence of any of the orthogonal polynomials. In this case they are also particularly useful as they eliminate one of the features that plagues the post-Newtonian expansion. The Chebyshev binding energy now has information at all post-Newtonian orders, compared to the post-Newtonian templates which only have information at full integer orders. In this work, we compare both the post-Newtonian and Chebyshev templates against a fiducially exact waveform. This waveform is constructed from a hybrid method of using the test-mass results combined with the mass dependent parts of the post-Newtonian expansions for the binding energy and flux functions. Our results show that the Chebyshev templates achieve extremely high fitting factors at all post-Newtonian orders and provide excellent parameter extraction. We also show that this new template family has a faster Cauchy convergence, gives a better prediction of the position of the last stable orbit and in general recovers higher Signal-to-Noise ratios than the post-Newtonian templates.

  2. Value of the cumulative sum test for the assessment of a learning curve: Application to the introduction of patient-specific instrumentation for total knee arthroplasty in an academic department.

    PubMed

    De Gori, Marco; Adamczewski, Benjamin; Jenny, Jean-Yves

    2017-06-01

    The purpose of the study was to use the cumulative summation (CUSUM) test to assess the learning curve during the introduction of a new surgical technique (patient-specific instrumentation) in total knee arthroplasty (TKA) in an academic department. The first 50TKAs operated on at an academic department using patient-specific templates (PSTs) were scheduled to enter the study. All patients had a preoperative computed tomography scan evaluation to plan bone resections. The PSTs were positioned intraoperatively according to the best-fit technique and their three-dimensional orientation was recorded by a navigation system. The position of the femur and tibia PST was compared to the planned position for four items for each component: coronal and sagittal orientation, medial and lateral height of resection. Items were summarized to obtain knee, femur and tibia PST scores, respectively. These scores were plotted according to chronological order and included in a CUSUM analysis. The tested hypothesis was that the PST process for TKA was immediately under control after its introduction. CUSUM test showed that positioning of the PST significantly differed from the target throughout the study. There was a significant difference between all scores and the maximal score. No case obtained the maximal score of eight points. The study was interrupted after 20 cases because of this negative evaluation. The CUSUM test is effective in monitoring the learning curve when introducing a new surgical procedure. Introducing PST for TKA in an academic department may be associated with a long-lasting learning curve. The study was registered on the clinical.gov website (Identifier NCT02429245). Copyright © 2017 Elsevier B.V. All rights reserved.

  3. SU-E-T-301: Dosimetric Comparison Between Adaptive and Rectilinear Template-Based Prostate Seed Implants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sugar, E Neubauer; Buzurovic, I; O’Farrell, D

    2015-06-15

    Purpose: To compare the dosimetry of a standard rectilinear and an adaptive technique used in I125 prostate seed implants. Methods: To achieve favorable dosimetry in prostate implants we used adaptive needle updates to match actual positions in real-time. The seed locations were optimized based on actual needle locations. The seeds were delivered automatically with a robotic device seedSelectron™ (Elekta Brachytherapy). In this study, we evaluated the former approach against the standard rectilinear technique in which the needles have a parallel distribution. The treatment plans for 10 patients were analyzed. For comparison, the actual treatment plans were revised so each needlemore » was repositioned to its original parallel location through the template. The analysis was performed by comparing the target coverage and dose to the organs at risk. The comparison was done using the following planning goals: the target D90> 90%, V100% > 90%, V50% <70% and V200% <30%; the urethra V125% < 1cm3 and V150%= 0cm3; and the Rectum V100%<1cm3 and V69% < 8cm3. The prescription dose to the target was 145Gy. Results: The average target volume and number of seeds were 44.39cm3(SD=11.14) and 74(SD=12), respectively. The D90 for adaptive and rectilinear plans was 159.9Gy(SD=2.99) and 155.53Gy(SD=4.04) resulting in a 2.74% difference for the average target coverage. A similar difference (1.75%) was noticed in the target V100[%]. No significant difference was noticed in the dose to the urethra and rectum. All planning goals were met with both the adaptive and rectilinear approach for each plan. Conclusion: The study reveals enhanced coverage of the target when using the adaptive needle adjustments as compared to the rectilinear approach for the analyzed cases. However, the differences in dosimetry did not translate to meaningful clinical outcomes.« less

  4. VizieR Online Data Catalog: Intrinsic far-IR SED of luminous AGNs (Lyu+, 2017)

    NASA Astrophysics Data System (ADS)

    Lyu, J.; Rieke, G. H.

    2018-01-01

    The range of currently proposed active galactic nucleus (AGN) far-infrared templates results in uncertainties in retrieving host galaxy information from infrared observations and also undermines constraints on the outer part of the AGN torus. We discuss how to test and reconcile these templates. Physically, the fraction of the intrinsic AGN IR-processed luminosity compared with that from the central engine should be consistent with the dust-covering factor. In addition, besides reproducing the composite spectral energy distributions (SEDs) of quasars, a correct AGN IR template combined with an accurate library of star-forming galaxy templates should be able to reproduce the IR properties of the host galaxies, such as the luminosity-dependent SED shapes and aromatic feature strengths. We develop tests based on these expected behaviors and find that the shape of the AGN intrinsic far-IR emission drops off rapidly starting at ~20μm and can be matched by an Elvis+ (1994, J/ApJS/95/1)-like template with a minor modification. Despite the variations in the near- to mid-IR bands, AGNs in quasars and Seyfert galaxies have remarkably similar intrinsic far-IR SEDs at λ~20-100μm, suggesting a similar emission character of the outermost region of the circumnuclear torus. The variations of the intrinsic AGN IR SEDs among the type-1 quasar population can be explained by the changing relative strengths of four major dust components with similar characteristic temperatures, and there is evidence for compact AGN-heated dusty structures at sub-kiloparsec scales in the far-IR. (3 data files).

  5. Rational design of molecularly imprinted polymer: the choice of cross-linker.

    PubMed

    Muhammad, Turghun; Nur, Zohre; Piletska, Elena V; Yimit, Osmanjan; Piletsky, Sergey A

    2012-06-07

    The paper describes a rational approach for the selection of cross-linkers during the development of molecularly imprinted polymers (MIPs). As a model system for this research MIPs specific for the drug zidovudine (AZT) were designed and tested. Three cross-linkers trimethylolpropane trimethacrylate (TRIM), ethylene glycol dimethacrylate (EGDMA) and divinylbenzene (DVB) were studied. The analogue of zidovudine (AZT) ester (AZT-ES) was used as a dummy template. The imprinting factors for all of the polymers in the static adsorption experiments were calculated. The data on the AZT adsorption by control polymers (CP), which were prepared with different cross-linkers without a functional monomer, was also analyzed. DVB was found to be more inert towards zidovudine than EGDMA and TRIM, which was confirmed by both molecular modelling and adsorption experiments. It was demonstrated that DVB-based polymers had a higher imprinting factor (I = 1.85) compared with other tested cross-linked polymers. It was suggested that the selection of the cross-linker should be based on the strength of the interaction with the template: the cross-linker which displays lower binding of the template should be preferential because it generates MIPs with lower non-specific binding and a higher imprinting factor, and therefore specificity. Which cross-linker to use for the preparation of any particular MIP can be determined by analysis of the interactions between the cross-linker and template. This could be done either virtually using computational modelling or by template adsorption using a small library of polymers prepared using different cross-linkers.

  6. The Intrinsic Far-infrared Continua of Type-1 Quasars

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lyu, Jianwei; Rieke, George H., E-mail: jianwei@email.arizona.edu

    2017-06-01

    The range of currently proposed active galactic nucleus (AGN) far-infrared templates results in uncertainties in retrieving host galaxy information from infrared observations and also undermines constraints on the outer part of the AGN torus. We discuss how to test and reconcile these templates. Physically, the fraction of the intrinsic AGN IR-processed luminosity compared with that from the central engine should be consistent with the dust-covering factor. In addition, besides reproducing the composite spectral energy distributions (SEDs) of quasars, a correct AGN IR template combined with an accurate library of star-forming galaxy templates should be able to reproduce the IR propertiesmore » of the host galaxies, such as the luminosity-dependent SED shapes and aromatic feature strengths. We develop tests based on these expected behaviors and find that the shape of the AGN intrinsic far-IR emission drops off rapidly starting at ∼20 μ m and can be matched by an Elvis et al.-like template with a minor modification. Despite the variations in the near- to mid-IR bands, AGNs in quasars and Seyfert galaxies have remarkably similar intrinsic far-IR SEDs at λ ∼ 20–100 μ m, suggesting a similar emission character of the outermost region of the circumnuclear torus. The variations of the intrinsic AGN IR SEDs among the type-1 quasar population can be explained by the changing relative strengths of four major dust components with similar characteristic temperatures, and there is evidence for compact AGN-heated dusty structures at sub-kiloparsec scales in the far-IR.« less

  7. Templated synthesis of nanoporous titania/nanocarbon composites

    NASA Astrophysics Data System (ADS)

    Mistry, Jayur

    Hexagonally patterned (honeycomb structured) nano-porous titania finds distinct applications in the field of material science, electronics, and catalysis. The preparation of titania/nanocarbon composites was carried out using titanium iso-propoxide precursor and a viscous surfactant templated system arranged into nanoscopic channels of water and iso-octane. Nanocarbon was introduced into the titania pores, as it was dispersed into the water (used to increase the W0), while making templets. Prepared titania/nanocarbon composites were analyzed under scanning electron microscopy (SEM), transmission electron microscope (TEM), and X-ray diffraction (XRD) after a specific heat treatment. SEM and TEM allows us to see the morphology of the hexagonally patterned templates and XRD shows the change in the crystallinity of the titania after the heat treatment. Further tests are run with the Solartron™ CellTest potentiostat syste, which, allows us to study the electrical properties of the nanocomposites. The composites synthesized have wide applications in number of fields, including energy, sensors and electronics.

  8. A Waveform Detector that Targets Template-Decorrelated Signals and Achieves its Predicted Performance: Demonstration with IMS Data

    NASA Astrophysics Data System (ADS)

    Carmichael, J.

    2016-12-01

    Waveform correlation detectors used in seismic monitoring scan multichannel data to test two competing hypotheses: that data contain (1) a noisy, amplitude-scaled version of a template waveform, or, (2) only noise. In reality, seismic wavefields include signals triggered by non-target sources (background seismicity) and target signals that are only partially correlated with the waveform template. We reform the waveform correlation detector hypothesis test to accommodate deterministic uncertainty in template/target waveform similarity and thereby derive a new detector from convex set projections (the "cone detector") for use in explosion monitoring. Our analyses give probability density functions that quantify the detectors' degraded performance with decreasing waveform similarity. We then apply our results to three announced North Korean nuclear tests and use International Monitoring System (IMS) arrays to determine the probability that low magnitude, off-site explosions can be reliably detected with a given waveform template. We demonstrate that cone detectors provide (1) an improved predictive capability over correlation detectors to identify such spatially separated explosive sources, (2) competitive detection rates, and (3) reduced false alarms on background seismicity. Figure Caption: Observed and predicted receiver operating characteristic curves for correlation statistic r(x) (left) and cone statistic s(x) (right) versus semi-empirical explosion magnitude. a: Shaded region shows range of ROC curves for r(x) that give the predicted detection performance in noise conditions recorded over 24 hrs on 8 October 2006. Superimposed stair plot shows the empirical detection performance (recorded detections/total events) averaged over 24 hr of data. Error bars indicate the demeaned range in observed detection probability over the day; means are removed to avoid risk of misinterpreting range to indicate probabilities can exceed one. b: Shaded region shows range of ROC curves for s(x) that give the predicted detection performance for the cone detector. Superimposed stair plot show observed detection performance averaged over 24 hr of data analogous to that shown in a.

  9. SU-G-JeP3-01: A Method to Quantify Lung SBRT Target Localization Accuracy Based On Digitally Reconstructed Fluoroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lafata, K; Ren, L; Cai, J

    2016-06-15

    Purpose: To develop a methodology based on digitally-reconstructed-fluoroscopy (DRF) to quantitatively assess target localization accuracy of lung SBRT, and to evaluate using both a dynamic digital phantom and a patient dataset. Methods: For each treatment field, a 10-phase DRF is generated based on the planning 4DCT. Each frame is pre-processed with a morphological top-hat filter, and corresponding beam apertures are projected to each detector plane. A template-matching algorithm based on cross-correlation is used to detect the tumor location in each frame. Tumor motion relative beam aperture is extracted in the superior-inferior direction based on each frame’s impulse response to themore » template, and the mean tumor position (MTP) is calculated as the average tumor displacement. The DRF template coordinates are then transferred to the corresponding MV-cine dataset, which is retrospectively filtered as above. The treatment MTP is calculated within each field’s projection space, relative to the DRF-defined template. The field’s localization error is defined as the difference between the DRF-derived-MTP (planning) and the MV-cine-derived-MTP (delivery). A dynamic digital phantom was used to assess the algorithm’s ability to detect intra-fractional changes in patient alignment, by simulating different spatial variations in the MV-cine and calculating the corresponding change in MTP. Inter-and-intra-fractional variation, IGRT accuracy, and filtering effects were investigated on a patient dataset. Results: Phantom results demonstrated a high accuracy in detecting both translational and rotational variation. The lowest localization error of the patient dataset was achieved at each fraction’s first field (mean=0.38mm), with Fx3 demonstrating a particularly strong correlation between intra-fractional motion-caused localization error and treatment progress. Filtering significantly improved tracking visibility in both the DRF and MV-cine images. Conclusion: We have developed and evaluated a methodology to quantify lung SBRT target localization accuracy based on digitally-reconstructed-fluoroscopy. Our approach may be useful in potentially reducing treatment margins to optimize lung SBRT outcomes. R01-184173.« less

  10. Simultaneous tumor and surrogate motion tracking with dynamic MRI for radiation therapy planning

    NASA Astrophysics Data System (ADS)

    Park, Seyoun; Farah, Rana; Shea, Steven M.; Tryggestad, Erik; Hales, Russell; Lee, Junghoon

    2018-01-01

    Respiration-induced tumor motion is a major obstacle for achieving high-precision radiotherapy of cancers in the thoracic and abdominal regions. Surrogate-based estimation and tracking methods are commonly used in radiotherapy, but with limited understanding of quantified correlation to tumor motion. In this study, we propose a method to simultaneously track the lung tumor and external surrogates to evaluate their spatial correlation in a quantitative way using dynamic MRI, which allows real-time acquisition without ionizing radiation exposure. To capture the lung and whole tumor, four MRI-compatible fiducials are placed on the patient’s chest and upper abdomen. Two different types of acquisitions are performed in the sagittal orientation including multi-slice 2D cine MRIs to reconstruct 4D-MRI and two-slice 2D cine MRIs to simultaneously track the tumor and fiducials. A phase-binned 4D-MRI is first reconstructed from multi-slice MR images using body area as a respiratory surrogate and groupwise registration. The 4D-MRI provides 3D template volumes for different breathing phases. 3D tumor position is calculated by 3D-2D template matching in which 3D tumor templates in the 4D-MRI reconstruction and the 2D cine MRIs from the two-slice tracking dataset are registered. 3D trajectories of the external surrogates are derived via matching a 3D geometrical model of the fiducials to their segmentations on the 2D cine MRIs. We tested our method on ten lung cancer patients. Using a correlation analysis, the 3D tumor trajectory demonstrates a noticeable phase mismatch and significant cycle-to-cycle motion variation, while the external surrogate was not sensitive enough to capture such variations. Additionally, there was significant phase mismatch between surrogate signals obtained from the fiducials at different locations.

  11. A Fast 3-Dimensional Magnetic Resonance Imaging Reconstruction for Surgical Planning of Uterine Myomectomy

    PubMed Central

    2017-01-01

    Background Uterine myoma is the most common benign gynecologic tumor in reproductive-aged women. During myomectomy for women who want to preserve fertility, it is advisable to detect and remove all myomas to decrease the risk of additional surgery. However, finding myomas during surgery is often challenging, especially for deep-seated myomas. Therefore, three-dimensional (3D) preoperative localization of myomas can be helpful for the surgical planning for myomectomy. However, the previously reported manual 3D segmenting method takes too much time and effort for clinical use. The objective of this study was to propose a new method of rapid 3D visualization of uterine myoma using a uterine template. Methods Magnetic resonance images were listed according to the slide spacing on each plane of the multiplanar reconstruction, and images that were determined to be myomas were selected by simply scrolling the mouse down. By using the selected images, a 3D grid with a slide spacing interval was constructed and filled on its plane and finally registered to a uterine template. Results The location of multiple myomas in the uterus was visualized in 3D and this proposed method is over 95% faster than the existing manual-segmentation method. Not only the size and location of the myomas, but also the shortest distance between the uterine surface and the myomas, can be calculated. This technique also enables the surgeon to know the number of total, removed, and remaining myomas on the 3D image. Conclusion This proposed 3D reconstruction method with a uterine template enables faster 3D visualization of myomas. PMID:29215821

  12. A template-free method for stable CuO hollow microspheres fabricated from a metal organic framework (HKUST-1).

    PubMed

    Zhang, Suoying; Liu, Hong; Liu, Pengfei; Yang, Zhuhong; Feng, Xin; Huo, Fengwei; Lu, Xiaohua

    2015-06-07

    Uniform CuO hollow microspheres were successfully achieved from a non-uniform metal organic framework by using a template-free method. The process mechanism has been revealed to be spherical aggregation and Ostwald ripening. When tested in CO oxidation and heat treatment, these assembled microspheres exhibited an excellent catalytic performance and show a much better stability than the inherited hollow structure from MOFs.

  13. Feasibility study of patient-specific surgical templates for the fixation of pedicle screws.

    PubMed

    Salako, F; Aubin, C-E; Fortin, C; Labelle, H

    2002-01-01

    Surgery for scoliosis, as well as other posterior spinal surgeries, frequently uses pedicle screws to fix an instrumentation on the spine. Misplacement of a screw can lead to intra- and post-operative complications. The objective of this study is to design patient-specific surgical templates to guide the drilling operation. From the CT-scan of a vertebra, the optimal drilling direction and limit angles are computed from an inverse projection of the pedicle limits. The first template design uses a surface-to-surface registration method and was constructed in a CAD system by subtracting the vertebra from a rectangular prism and a cylinder with the optimal orientation. This template and the vertebra were built using rapid prototyping. The second design uses a point-to-surface registration method and has 6 adjustable screws to adjust the orientation and length of the drilling support device. A mechanism was designed to hold it in place on the spinal process. A virtual prototype was build with CATIA software. During the operation, the surgeon places either template on patient's vertebra until a perfect match is obtained before drilling. The second design seems better than the first one because it can be reused on different vertebra and is less sensible to registration errors. The next step is to build the second design and make experimental and simulations tests to evaluate the benefits of this template during a scoliosis operation.

  14. HDOCK: a web server for protein–protein and protein–DNA/RNA docking based on a hybrid strategy

    PubMed Central

    Yan, Yumeng; Zhang, Di; Zhou, Pei; Li, Botong

    2017-01-01

    Abstract Protein–protein and protein–DNA/RNA interactions play a fundamental role in a variety of biological processes. Determining the complex structures of these interactions is valuable, in which molecular docking has played an important role. To automatically make use of the binding information from the PDB in docking, here we have presented HDOCK, a novel web server of our hybrid docking algorithm of template-based modeling and free docking, in which cases with misleading templates can be rescued by the free docking protocol. The server supports protein–protein and protein–DNA/RNA docking and accepts both sequence and structure inputs for proteins. The docking process is fast and consumes about 10–20 min for a docking run. Tested on the cases with weakly homologous complexes of <30% sequence identity from five docking benchmarks, the HDOCK pipeline tied with template-based modeling on the protein–protein and protein–DNA benchmarks and performed better than template-based modeling on the three protein–RNA benchmarks when the top 10 predictions were considered. The performance of HDOCK became better when more predictions were considered. Combining the results of HDOCK and template-based modeling by ranking first of the template-based model further improved the predictive power of the server. The HDOCK web server is available at http://hdock.phys.hust.edu.cn/. PMID:28521030

  15. Where do the 3.5 keV photons come from? A morphological study of the Galactic Center and of Perseus

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carlson, Eric; Jeltema, Tesla; Profumo, Stefano, E-mail: erccarls@ucsc.edu, E-mail: tesla@ucsc.edu, E-mail: profumo@ucsc.edu

    We test the origin of the 3.5 keV line photons by analyzing the morphology of the emission at that energy from the Galactic Center and from the Perseus cluster of galaxies. We employ a variety of different templates to model the continuum emission and analyze the resulting radial and azimuthal distribution of the residual emission. We then perform a pixel-by-pixel binned likelihood analysis including line emission templates and dark matter templates and assess the correlation of the 3.5 keV emission with these templates. We conclude that the radial and azimuthal distribution of the residual emission is incompatible with a darkmore » matter origin for both the Galactic center and Perseus; the Galactic center 3.5 keV line photons trace the morphology of lines at comparable energy, while the Perseus 3.5 keV photons are highly correlated with the cluster's cool core, and exhibit a morphology incompatible with dark matter decay. The template analysis additionally allows us to set the most stringent constraints to date on lines in the 3.5 keV range from dark matter decay.« less

  16. A difference tracking algorithm based on discrete sine transform

    NASA Astrophysics Data System (ADS)

    Liu, HaoPeng; Yao, Yong; Lei, HeBing; Wu, HaoKun

    2018-04-01

    Target tracking is an important field of computer vision. The template matching tracking algorithm based on squared difference matching (SSD) and standard correlation coefficient (NCC) matching is very sensitive to the gray change of image. When the brightness or gray change, the tracking algorithm will be affected by high-frequency information. Tracking accuracy is reduced, resulting in loss of tracking target. In this paper, a differential tracking algorithm based on discrete sine transform is proposed to reduce the influence of image gray or brightness change. The algorithm that combines the discrete sine transform and the difference algorithm maps the target image into a image digital sequence. The Kalman filter predicts the target position. Using the Hamming distance determines the degree of similarity between the target and the template. The window closest to the template is determined the target to be tracked. The target to be tracked updates the template. Based on the above achieve target tracking. The algorithm is tested in this paper. Compared with SSD and NCC template matching algorithms, the algorithm tracks target stably when image gray or brightness change. And the tracking speed can meet the read-time requirement.

  17. Mis-modelling in Gravitational Wave Astronomy: The Trouble with Templates

    NASA Astrophysics Data System (ADS)

    Sampson, Laura; Cornish, Neil; Yunes, Nicolas

    2014-03-01

    Waveform templates are a powerful tool for extracting and characterizing gravitational wave signals. There are, however, attendant dangers in using these highly restrictive signal priors. If strong field gravity is not accurately described by General Relativity (GR), then using GR templates may result in fundamental bias in the recovered parameters, or worse - a complete failure to detect signals. Here we study such dangers, concentrating on three distinct possibilities. First, we show that there exist modified theories compatible with all existing tests that would fail to be detected by the LIGO/Virgo network using searches based on GR templates, but which would be detected using a one parameter post-Einsteinian extension. Second, we study modified theories that produce departures from GR that do not naively fit into the simplest parameterized post-Einsteinian (ppE) scheme. We show that even the simplest ppE templates are still capable of picking up these strange signals and diagnosing a departure from GR. Third, we study how using inspiral-only ppE waveforms for signals that include merger and ringdown can lead to problems in misidentifying a GR departure. We present an easy technique that allows us to self-consistently identify the inspiral portion of the signal.

  18. The arrival of economic evidence in managed care formulary decisions: the unsolicited request process.

    PubMed

    Neumann, Peter J

    2005-07-01

    Managed care plans have traditionally resisted using economic evidence explicitly in drug formulary decisions, even as they used ever more aggressive and sophisticated processes for managing care. In recent years, this has changed as health plans have begun to adopt evidence-based and value-based formulary submission guidelines. The guidelines have the potential to serve as a national unifying template for pharmacy and therapeutics committees to consider clinical and economic information in a systematic and rigorous fashion. However, many questions remain about their use and about the nature of communications (called "unsolicited requests") from plans to drug companies for information. This article describes the unsolicited request process and its potential impact on the use of economic evidence in formulary decisions.

  19. The Accuracy of Computer Image-Guided Template for Mandibular Angle Ostectomy.

    PubMed

    Ye, Niansong; Long, Hu; Zhu, Songsong; Yang, Yunqiang; Lai, Wenli; Hu, Jing

    2015-02-01

    Mandibular angle ostectomy (MAO) is commonly used to correct prominent mandibular angles through an intraoral approach. However, limited vision in the operative site may lead to difficulties or complications during surgery. Therefore, it is necessary to develop an effective method for helping surgeons to perform MAO more precisely and safely. In this study, we report a novel method of a computer image-guided surgical template for navigation of MAO, and evaluate its accuracy and clinical outcomes. Nine patients with a prominent mandibular angle were enrolled in this study. A pair of stereolithographic templates was fabricated by computer-aided image design and 3D printing. In all cases, bilateral MAO was performed under the guide of these templates. Post-operative effects were evaluated by 3D curve functions and maximal shell-to-shell deviations. All patients were satisfied with their cosmetic outcomes. The mean and SD of ICC between R-Sim and R-Post were 0.958 ± 0.011; between L-Sim and L-Post, 0.965 ± 0.014; and between R-Post and L-Post, 0.964 ± 0.013. The maximal shell-to-shell deviations between the simulated mandibular contour and post-operative mandibular contour on the right and left sides were 2.02 ± 0.32 and 1.97 ± 0.41 mm, respectively. The results of this study suggest that this new technique could assist surgeons in making better pre-surgical plans and ensure more accurate and safer manipulation for completion of this procedure.

  20. Phylogeny, paleontology, and primates: do incomplete fossils bias the tree of life?

    PubMed

    Pattinson, David J; Thompson, Richard S; Piotrowski, Aleks K; Asher, Robert J

    2015-03-01

    Paleontological systematics relies heavily on morphological data that have undergone decay and fossilization. Here, we apply a heuristic means to assess how a fossil's incompleteness detracts from inferring its phylogenetic relationships. We compiled a phylogenetic matrix for primates and simulated the extinction of living species by deleting an extant taxon's molecular data and keeping only those morphological characters present in actual fossils. The choice of characters present in a given living taxon (the subject) was defined by those present in a given fossil (the template). By measuring congruence between a well-corroborated phylogeny to those incorporating artificial fossils, and by comparing real vs. random character distributions and states, we tested the information content of paleontological datasets and determined if extinction of a living species leads to bias in phylogeny reconstruction. We found a positive correlation between fossil completeness and topological congruence. Real fossil templates sampled for 36 or more of the 360 available morphological characters (including dental) performed significantly better than similarly complete templates with random states. Templates dominated by only one partition performed worse than templates with randomly sampled characters across partitions. The template based on the Eocene primate Darwinius masillae performs better than most other templates with a similar number of sampled characters, likely due to preservation of data across multiple partitions. Our results support the interpretation that Darwinius is strepsirhine, not haplorhine, and suggest that paleontological datasets are reliable in primate phylogeny reconstruction. © The Author(s) 2014. Published by Oxford University Press, on behalf of the Society of Systematic Biologists. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. Investigating Pre-Service Science Teachers (PSTs)’ Technological Pedagogical Content Knowledge Through Extended Content Representation (CoRe)

    NASA Astrophysics Data System (ADS)

    Agustin, R. R.; Liliasari, L.

    2017-02-01

    The purpose of this study was to attain an insight into pre-service science teachers’ technological pedagogical content knowledge (TPACK) as an integrative competency that is addressed by 21st century skills. The methods used in the study was descriptive. Nineteen pre-service science teachers (PSTs) of an educational university in Indonesia were involved in a semester long school science course. The course mainly develop students’ pedagogical content knowledge (PCK) by utilizing content representation (CoRe) template. Furthermore an infusion of technological knowledge (TK) analysis led to the study of their TPACK by extending the template with a question in line to TK. The extended CoRe and self-reported survey were employed as instruments. The analysis of data used were quantitative and qualitative technique to obtain the insight into PSTs’ PCK and TK. The results shows contrary value of PCK and TK identified by CoRe template to those measured by self-reported survey. However, the PSTs perceive their TPACK much higher, that, is 74.74%. Further investigation regarding PSTs ability to compose lesson plan was recommended for further research to capture more comprehensive insight into PSTs’ TPACK.

  2. What Kind of Doctor Do You Want to Be? Geriatric Medicine Podcast as a Career Planning Resource.

    PubMed

    Byszewski, Anna; Bezzina, Kathryn; Latrous, Meriem

    2017-01-01

    For optimal direction in career paths and postgraduate training, students can benefit from information to guide them through options. Using geriatric medicine as a template, the goal was to develop a multimedia podcast resource that can give a clearer picture of what a specialty entails. The project included a survey of existing resources and needs assessment of medical students at the University of Ottawa, Canada. This survey assessed students' knowledge of geriatrics and interest in the field and explored what they foresee as being important to be informed on when considering application to programs. Based on this, interview questions and content were developed for a podcast which was then evaluated. Interviews were conducted with physicians and residents nationwide. Relevant resources and links were added to the podcast. Evaluation demonstrated improved student understanding and interest in geriatric medicine as a career. Point-by-point format for a template on how to develop similar podcasts was developed to assist other specialties looking to develop similar information. As no such framework currently exists, results of this project can serve as a template for other postgraduate programs in developing a multimedia resource for informing prospective trainees.

  3. SU-E-T-446: Group-Sparsity Based Angle Generation Method for Beam Angle Optimization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gao, H

    2015-06-15

    Purpose: This work is to develop the effective algorithm for beam angle optimization (BAO), with the emphasis on enabling further improvement from existing treatment-dependent templates based on clinical knowledge and experience. Methods: The proposed BAO algorithm utilizes a priori beam angle templates as the initial guess, and iteratively generates angular updates for this initial set, namely angle generation method, with improved dose conformality that is quantitatively measured by the objective function. That is, during each iteration, we select “the test angle” in the initial set, and use group-sparsity based fluence map optimization to identify “the candidate angle” for updating “themore » test angle”, for which all the angles in the initial set except “the test angle”, namely “the fixed set”, are set free, i.e., with no group-sparsity penalty, and the rest of angles including “the test angle” during this iteration are in “the working set”. And then “the candidate angle” is selected with the smallest objective function value from the angles in “the working set” with locally maximal group sparsity, and replaces “the test angle” if “the fixed set” with “the candidate angle” has a smaller objective function value by solving the standard fluence map optimization (with no group-sparsity regularization). Similarly other angles in the initial set are in turn selected as “the test angle” for angular updates and this chain of updates is iterated until no further new angular update is identified for a full loop. Results: The tests using the MGH public prostate dataset demonstrated the effectiveness of the proposed BAO algorithm. For example, the optimized angular set from the proposed BAO algorithm was better the MGH template. Conclusion: A new BAO algorithm is proposed based on the angle generation method via group sparsity, with improved dose conformality from the given template. Hao Gao was partially supported by the NSFC (#11405105), the 973 Program (#2015CB856000) and the Shanghai Pujiang Talent Program (#14PJ1404500)« less

  4. A novel superparamagnetic surface molecularly imprinted nanoparticle adopting dummy template: an efficient solid-phase extraction adsorbent for bisphenol A.

    PubMed

    Lin, Zhenkun; Cheng, Wenjing; Li, Yanyan; Liu, Zhiren; Chen, Xiangping; Huang, Changjiang

    2012-03-30

    Leakage of the residual template molecules is one of the biggest challenges for application of molecularly imprinted polymer (MIP) in solid-phase extraction (SPE). In this study, bisphenol F (BPF) was adopted as a dummy template to prepare MIP of bisphenol A (BPA) with a superparamagnetic core-shell nanoparticle as the supporter, aiming to avoid residual template leakage and to increase the efficiency of SPE. Characterization and test of the obtained products (called mag-DMIP beads) revealed that these novel nanoparticles not only had excellent magnetic property but also displayed high selectivity to the target molecule BPA. As mag-DMIP beads were adopted as the adsorbents of solid-phase extraction for detecting BPA in real water samples, the recoveries of spiked samples ranged from 84.7% to 93.8% with the limit of detection of 2.50 pg mL(-1), revealing that mag-DMIP beads were efficient SPE adsorbents. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. International developments in openEHR archetypes and templates.

    PubMed

    Leslie, Heather

    Electronic Health Records (EHRs) are a complex knowledge domain. The ability to design EHRs to cope with the changing nature of health knowledge, and to be shareable, has been elusive. A recent pilot study1 tested the applicability of the CEN 13606 as an electronic health record standard. Using openEHR archetypes and tools2, 650 clinical content specifi cations (archetypes) were created (e.g. for blood pressure) and re-used across all clinical specialties and contexts. Groups of archetypes were aggregated in templates to support clinical information gathering or viewing (e.g. 80 separate archetypes make up the routine antenatal visit record). Over 60 templates were created for use in the emergency department, antenatal care and delivery of an infant, and paediatric hearing loss assessment. The primary goal is to define a logical clinical record architecture for the NHS but potentially, with archetypes as the keystone, shareable EHRs will also be attainable. Archetype and template development work is ongoing, with associated evaluation occurring in parallel.

  6. Developmental validation of a Cannabis sativa STR multiplex system for forensic analysis.

    PubMed

    Howard, Christopher; Gilmore, Simon; Robertson, James; Peakall, Rod

    2008-09-01

    A developmental validation study based on recommendations of the Scientific Working Group on DNA Analysis Methods (SWGDAM) was conducted on a multiplex system of 10 Cannabis sativa short tandem repeat loci. Amplification of the loci in four multiplex reactions was tested across DNA from dried root, stem, and leaf sources, and DNA from fresh, frozen, and dried leaf tissue with a template DNA range of 10.0-0.01 ng. The loci were amplified and scored consistently for all DNA sources when DNA template was in the range of 10.0-1.0 ng. Some allelic dropout and PCR failure occurred in reactions with lower template DNA amounts. Overall, amplification was best using 10.0 ng of template DNA from dried leaf tissue indicating that this is the optimal source material. Cross species amplification was observed in Humulus lupulus for three loci but there was no allelic overlap. This is the first study following SWGDAM validation guidelines to validate short tandem repeat markers for forensic use in plants.

  7. Modulation of α-synuclein fibrillization by ring-fused 2-pyridones: templation and inhibition involve oligomers with different structure.

    PubMed

    Horvath, Istvan; Sellstedt, Magnus; Weise, Christoph; Nordvall, Lina-Maria; Krishna Prasad, G; Olofsson, Anders; Larsson, Göran; Almqvist, Fredrik; Wittung-Stafshede, Pernilla

    2013-04-15

    In a recent study we discovered that a ring-fused 2-pyridone compound triggered fibrillization of a key protein in Parkinson's disease, α-synuclein. To reveal how variations in compound structure affect protein aggregation, we now prepared a number of strategic analogs and tested their effects on α-synuclein amyloid fiber formation in vitro. We find that, in contrast to the earlier templating effect, some analogs inhibit α-synuclein fibrillization. For both templating and inhibiting compounds, the key species formed in the reactions are α-synuclein oligomers that contain compound. Despite similar macroscopic appearance, the templating and inhibiting oligomers are distinctly different in secondary structure content. When the inhibitory oligomers are added in seed amounts, they inhibit fresh α-synuclein aggregation reactions. Our study demonstrates that small chemical changes to the same central fragment can result in opposite effects on protein aggregation. Copyright © 2013 Elsevier Inc. All rights reserved.

  8. Engineering and algorithm design for an image processing Api: a technical report on ITK--the Insight Toolkit.

    PubMed

    Yoo, Terry S; Ackerman, Michael J; Lorensen, William E; Schroeder, Will; Chalana, Vikram; Aylward, Stephen; Metaxas, Dimitris; Whitaker, Ross

    2002-01-01

    We present the detailed planning and execution of the Insight Toolkit (ITK), an application programmers interface (API) for the segmentation and registration of medical image data. This public resource has been developed through the NLM Visible Human Project, and is in beta test as an open-source software offering under cost-free licensing. The toolkit concentrates on 3D medical data segmentation and registration algorithms, multimodal and multiresolution capabilities, and portable platform independent support for Windows, Linux/Unix systems. This toolkit was built using current practices in software engineering. Specifically, we embraced the concept of generic programming during the development of these tools, working extensively with C++ templates and the freedom and flexibility they allow. Software development tools for distributed consortium-based code development have been created and are also publicly available. We discuss our assumptions, design decisions, and some lessons learned.

  9. Enhancing the many-to-many relations across IHE document sharing communities.

    PubMed

    Ribeiro, Luís S; Costa, Carlos; Oliveira, José Luís

    2012-01-01

    The Integrating Healthcare Enterprise (IHE) initiative is an ongoing project aiming to enable true inter-site interoperability in the health IT field. IHE is a work in progress and many challenges need to be overcome before the healthcare Institutions may share patient clinical records transparently and effortless. Configuring, deploying and testing an IHE document sharing community requires a significant effort to plan and maintain the supporting IT infrastructure. With the new paradigm of cloud computing is now possible to launch software devices on demand and paying accordantly to the usage. This paper presents a framework designed with purpose of expediting the creation of IHE document sharing communities. It provides semi-ready templates of sharing communities that will be customized according the community needs. The framework is a meeting point of the healthcare institutions, creating a favourable environment that might converge in new inter-institutional professional relationships and eventually the creation of new Affinity Domains.

  10. Reduced dose to urethra and rectum with the use of variable needle spacing in prostate brachytherapy: a potential role for robotic technology

    PubMed Central

    Vyas, Shilpa; Le, Yi; Zhang, Zhe; Armour, Woody

    2015-01-01

    Purpose Several robotic delivery systems for prostate brachytherapy are under development or in pre-clinical testing. One of the features of robotic brachytherapy is the ability to vary spacing of needles at non-fixed intervals. This feature may play an important role in prostate brachytherapy, which is traditionally template-based with fixed needle spacing of 0.5 cm. We sought to quantify potential reductions in the dose to urethra and rectum by utilizing variable needle spacing, as compared to fixed needle spacing. Material and methods Transrectal ultrasound images from 10 patients were used by 3 experienced planners to create 120 treatment plans. Each planner created 4 plan variations per patient with respect to needle positions: 125I fixed spacing, 125I variable spacing, 103Pd fixed spacing, and 103Pd variable spacing. The primary planning objective was to achieve a prostate V100 of 100% while minimizing dose to urethra and rectum. Results All plans met the objective of achieving prostate V100 of 100%. Combined results for all plans show statistically significant improvements in all assessed dosimetric variables for urethra (Umax, Umean, D30, D5) and rectum (Rmax, Rmean, RV100) when using variable spacing. The dose reductions for mean and maximum urethra dose using variable spacing had p values of 0.011 and 0.024 with 103Pd, and 0.007 and 0.029 with 125I plans. Similarly dose reductions for mean and maximum rectal dose using variable spacing had p values of 0.007 and 0.052 with 103Pd, and 0.012 and 0.037 with 125I plans. Conclusions The variable needle spacing achievable by the use of robotics in prostate brachytherapy allows for reductions in both urethral and rectal planned doses while maintaining prostate dose coverage. Such dosimetric advantages have the potential in translating to significant clinical benefits with the use of robotic brachytherapy. PMID:26622227

  11. Reduced dose to urethra and rectum with the use of variable needle spacing in prostate brachytherapy: a potential role for robotic technology.

    PubMed

    Vyas, Shilpa; Le, Yi; Zhang, Zhe; Armour, Woody; Song, Daniel Y

    2015-08-01

    Several robotic delivery systems for prostate brachytherapy are under development or in pre-clinical testing. One of the features of robotic brachytherapy is the ability to vary spacing of needles at non-fixed intervals. This feature may play an important role in prostate brachytherapy, which is traditionally template-based with fixed needle spacing of 0.5 cm. We sought to quantify potential reductions in the dose to urethra and rectum by utilizing variable needle spacing, as compared to fixed needle spacing. Transrectal ultrasound images from 10 patients were used by 3 experienced planners to create 120 treatment plans. Each planner created 4 plan variations per patient with respect to needle positions: (125)I fixed spacing, (125)I variable spacing, (103)Pd fixed spacing, and (103)Pd variable spacing. The primary planning objective was to achieve a prostate V100 of 100% while minimizing dose to urethra and rectum. All plans met the objective of achieving prostate V100 of 100%. Combined results for all plans show statistically significant improvements in all assessed dosimetric variables for urethra (Umax, Umean, D30, D5) and rectum (Rmax, Rmean, RV100) when using variable spacing. The dose reductions for mean and maximum urethra dose using variable spacing had p values of 0.011 and 0.024 with (103)Pd, and 0.007 and 0.029 with (125)I plans. Similarly dose reductions for mean and maximum rectal dose using variable spacing had p values of 0.007 and 0.052 with (103)Pd, and 0.012 and 0.037 with (125)I plans. The variable needle spacing achievable by the use of robotics in prostate brachytherapy allows for reductions in both urethral and rectal planned doses while maintaining prostate dose coverage. Such dosimetric advantages have the potential in translating to significant clinical benefits with the use of robotic brachytherapy.

  12. The Feasibility of Using Computer and Internet in Teaching Family Education for the 8th Grade Class

    ERIC Educational Resources Information Center

    Alluhaydan, Nuwayyir Saleh F.

    2016-01-01

    This paper is just a sample template for the prospective authors of IISTE. Over the decades, the concepts of holons and holonic systems have been adopted in many research fields, but they are scarcely attempted on labour planning. A literature gap exists, thus motivating the author to come up with a holonic model that uses exponential smoothing to…

  13. Toward a Natural Speech Understanding System

    DTIC Science & Technology

    1989-10-01

    WALTER J. SENUS Technical Director Directorate of Intelligence & Reconnaissance FOR THE COMMANDER JAMES W. HYDE III V Directorate of Plans & Programs ...applicable) Human Resources Laboratory F30602-81-C-0193 8 . ADDRESS (City, State, and ZIP Code) 10. SOURCE OF FUNDING NUMBERS PROGRAM PROJECT TASK WORK...error rates for distinctive words produced in isolation by a single speaker, and their simple programming requirements. Template-matching systems rank

  14. Development of a Template Lesson Plan Based on 5e Model Enhanced with Computer Supported Applications and Conceptual Change Texts

    ERIC Educational Resources Information Center

    Seker, Burcu Sezginsoy; Erdem, Aliye

    2017-01-01

    Students learning a defined subject only perform by learning of thinking based on the concepts forming that subjects. Otherwise, students may move away from the scientific meaning of concepts and may fall into conceptual errors. Students' conceptual errors affect their following learning and cause them resist change. It is possible to prevent this…

  15. U.S. Department of the Interior, Bureau of Indian Education State Performance Plan. SPP Template-Part B. Revised May 17, 2013

    ERIC Educational Resources Information Center

    Bureau of Indian Education, 2013

    2013-01-01

    The Bureau of Indian Education (BIE) funds schools located on 63 reservations in 23 states across the nation. Of the 183 schools, 59 are Bureau operated and 124 are tribally controlled. One-hundred and sixteen schools provide instructional programs, 55 provide instructional as well as boarding services and 12 peripheral dormitories provide only…

  16. Automatic tracking of arbitrarily shaped implanted markers in kilovoltage projection images: A feasibility study

    PubMed Central

    Regmi, Rajesh; Lovelock, D. Michael; Hunt, Margie; Zhang, Pengpeng; Pham, Hai; Xiong, Jianping; Yorke, Ellen D.; Goodman, Karyn A.; Rimner, Andreas; Mostafavi, Hassan; Mageras, Gig S.

    2014-01-01

    Purpose: Certain types of commonly used fiducial markers take on irregular shapes upon implantation in soft tissue. This poses a challenge for methods that assume a predefined shape of markers when automatically tracking such markers in kilovoltage (kV) radiographs. The authors have developed a method of automatically tracking regularly and irregularly shaped markers using kV projection images and assessed its potential for detecting intrafractional target motion during rotational treatment. Methods: Template-based matching used a normalized cross-correlation with simplex minimization. Templates were created from computed tomography (CT) images for phantom studies and from end-expiration breath-hold planning CT for patient studies. The kV images were processed using a Sobel filter to enhance marker visibility. To correct for changes in intermarker relative positions between simulation and treatment that can introduce errors in automatic matching, marker offsets in three dimensions were manually determined from an approximately orthogonal pair of kV images. Two studies in anthropomorphic phantom were carried out, one using a gold cylindrical marker representing regular shape, another using a Visicoil marker representing irregular shape. Automatic matching of templates to cone beam CT (CBCT) projection images was performed to known marker positions in phantom. In patient data, automatic matching was compared to manual matching as an approximate ground truth. Positional discrepancy between automatic and manual matching of less than 2 mm was assumed as the criterion for successful tracking. Tracking success rates were examined in kV projection images from 22 CBCT scans of four pancreas, six gastroesophageal junction, and one lung cancer patients. Each patient had at least one irregularly shaped radiopaque marker implanted in or near the tumor. In addition, automatic tracking was tested in intrafraction kV images of three lung cancer patients with irregularly shaped markers during 11 volumetric modulated arc treatments. Purpose-built software developed at our institution was used to create marker templates and track the markers embedded in kV images. Results: Phantom studies showed mean ± standard deviation measurement uncertainty of automatic registration to be 0.14 ± 0.07 mm and 0.17 ± 0.08 mm for Visicoil and gold cylindrical markers, respectively. The mean success rate of automatic tracking with CBCT projections (11 frames per second, fps) of pancreas, gastroesophageal junction, and lung cancer patients was 100%, 99.1% (range 98%–100%), and 100%, respectively. With intrafraction images (approx. 0.2 fps) of lung cancer patients, the success rate was 98.2% (range 97%–100%), and 94.3% (range 93%–97%) using templates from 1.25 mm and 2.5 mm slice spacing CT scans, respectively. Correction of intermarker relative position was found to improve the success rate in two out of eight patients analyzed. Conclusions: The proposed method can track arbitrary marker shapes in kV images using templates generated from a breath-hold CT acquired at simulation. The studies indicate its feasibility for tracking tumor motion during rotational treatment. Investigation of the causes of misregistration suggests that its rate of incidence can be reduced with higher frequency of image acquisition, templates made from smaller CT slice spacing, and correction of changes in intermarker relative positions when they occur. PMID:24989384

  17. Automatic tracking of arbitrarily shaped implanted markers in kilovoltage projection images: A feasibility study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Regmi, Rajesh; Lovelock, D. Michael; Hunt, Margie

    Purpose: Certain types of commonly used fiducial markers take on irregular shapes upon implantation in soft tissue. This poses a challenge for methods that assume a predefined shape of markers when automatically tracking such markers in kilovoltage (kV) radiographs. The authors have developed a method of automatically tracking regularly and irregularly shaped markers using kV projection images and assessed its potential for detecting intrafractional target motion during rotational treatment. Methods: Template-based matching used a normalized cross-correlation with simplex minimization. Templates were created from computed tomography (CT) images for phantom studies and from end-expiration breath-hold planning CT for patient studies. Themore » kV images were processed using a Sobel filter to enhance marker visibility. To correct for changes in intermarker relative positions between simulation and treatment that can introduce errors in automatic matching, marker offsets in three dimensions were manually determined from an approximately orthogonal pair of kV images. Two studies in anthropomorphic phantom were carried out, one using a gold cylindrical marker representing regular shape, another using a Visicoil marker representing irregular shape. Automatic matching of templates to cone beam CT (CBCT) projection images was performed to known marker positions in phantom. In patient data, automatic matching was compared to manual matching as an approximate ground truth. Positional discrepancy between automatic and manual matching of less than 2 mm was assumed as the criterion for successful tracking. Tracking success rates were examined in kV projection images from 22 CBCT scans of four pancreas, six gastroesophageal junction, and one lung cancer patients. Each patient had at least one irregularly shaped radiopaque marker implanted in or near the tumor. In addition, automatic tracking was tested in intrafraction kV images of three lung cancer patients with irregularly shaped markers during 11 volumetric modulated arc treatments. Purpose-built software developed at our institution was used to create marker templates and track the markers embedded in kV images. Results: Phantom studies showed mean ± standard deviation measurement uncertainty of automatic registration to be 0.14 ± 0.07 mm and 0.17 ± 0.08 mm for Visicoil and gold cylindrical markers, respectively. The mean success rate of automatic tracking with CBCT projections (11 frames per second, fps) of pancreas, gastroesophageal junction, and lung cancer patients was 100%, 99.1% (range 98%–100%), and 100%, respectively. With intrafraction images (approx. 0.2 fps) of lung cancer patients, the success rate was 98.2% (range 97%–100%), and 94.3% (range 93%–97%) using templates from 1.25 mm and 2.5 mm slice spacing CT scans, respectively. Correction of intermarker relative position was found to improve the success rate in two out of eight patients analyzed. Conclusions: The proposed method can track arbitrary marker shapes in kV images using templates generated from a breath-hold CT acquired at simulation. The studies indicate its feasibility for tracking tumor motion during rotational treatment. Investigation of the causes of misregistration suggests that its rate of incidence can be reduced with higher frequency of image acquisition, templates made from smaller CT slice spacing, and correction of changes in intermarker relative positions when they occur.« less

  18. A spreadsheet template compatible with Microsoft Excel and iWork Numbers that returns the simultaneous confidence intervals for all pairwise differences between multiple sample means.

    PubMed

    Brown, Angus M

    2010-04-01

    The objective of the method described in this paper is to develop a spreadsheet template for the purpose of comparing multiple sample means. An initial analysis of variance (ANOVA) test on the data returns F--the test statistic. If F is larger than the critical F value drawn from the F distribution at the appropriate degrees of freedom, convention dictates rejection of the null hypothesis and allows subsequent multiple comparison testing to determine where the inequalities between the sample means lie. A variety of multiple comparison methods are described that return the 95% confidence intervals for differences between means using an inclusive pairwise comparison of the sample means. 2009 Elsevier Ireland Ltd. All rights reserved.

  19. Using the false memory paradigm to test two key elements of alcohol expectancy theory.

    PubMed

    Reich, Richard R; Goldman, Mark S; Noll, Jane A

    2004-05-01

    Two key aspects of alcohol expectancy theory--(a) that memories about alcohol effects are stored as relatively cohesive templates of information and (b) that these templates are automatically activated in alcohol-related contexts--were tested using the Deese-Roediger- McDermott false memory paradigm. Alcohol expectancy adjectives were studied, and false memory for expectancy target words was tested in neutral and alcohol contexts. Results indicated that in the alcohol context heavier drinkers showed more false memory for alcohol expectancy words than they did in a neutral context. Differences were not found for lighter drinkers. These results were consistent with alcohol expectancy theory, which was then compared with various forms of association theory in explaining these results and larger issues in the addiction field. ((c) 2004 APA, all rights reserved)

  20. Problem-Solving Test: Pyrosequencing

    ERIC Educational Resources Information Center

    Szeberenyi, Jozsef

    2013-01-01

    Terms to be familiar with before you start to solve the test: Maxam-Gilbert sequencing, Sanger sequencing, gel electrophoresis, DNA synthesis reaction, polymerase chain reaction, template, primer, DNA polymerase, deoxyribonucleoside triphosphates, orthophosphate, pyrophosphate, nucleoside monophosphates, luminescence, acid anhydride bond,…

  1. Local Action Plans for Forest Fire Prevention in Greece: Existing situation and a Proposed Template based on the Collaboration of Academics and Public Policy Makers

    NASA Astrophysics Data System (ADS)

    Papanikolaou, Dimitrios; Arvanitakis, Spyridon; Papanikolaou, , Ioannis; Lozios, Stylianos; Diakakis, Michalis; Deligiannakis, Georgios; Dimitropoulou, Margarita; Georgiou, Konstantinos

    2013-04-01

    Wildfires are a major hazard in Greece suffering on average 1,509 wildfires and 36,151 burned hectares of forestlands every year. Since 1998 the Greek Fire Service is responsible for wildfires suppression and response, while prevention and mitigation yearly directives are also being released by the General Secretariat of Civil Protection. The 3013/2002 Act introduced a major transfer of responsibilities from the national to local municipal and regional authorities, which are accompanied by supplementary financial support. Significant new features were established such as the operation of local coordination councils, the foundation of municipality civil protection offices, the establishment of the annually prevention planning for forest fires and the development of local action plans. The University of Athens has developed a Local Action Plan template for municipality administrative levels, integrating scientific techniques and technologies to public government management. The Local Action Plan for Forest Fire Prevention is the main handbook and primary tool of every municipality for reducing the risk of wildfires. Fire prevention and risk analysis are the principal aims of this Plan, which also emphasizes on the important role of the volunteer organizations on forest fire prevention. The 7 chapters of the Action Plan include the legal framework, the risk analysis parameters, the risk analysis using GIS, the prevention planning, the manpower and available equipment of services involved, along with operational planning and evaluation of the previous year's forest fire prevention actions. Multiple information layers, such as vegetation types, road network, power lines and landfills are combined in GIS environment and transformed into qualitative multiparameter as well as quantitative combinational fire hazard maps. These maps are essential in wildfire risk analysis as they display the areas that need the highest attention during the fire season. Moreover, the separate steps of operational planning and the reviewing of precaution, addressing and rehabilitation measures are analyzed. This action plan, risk analysis and maps are of decisive importance not only for prevention and operational planning purposes, but can also prove useful during the crisis and the rehabilitation processes as well. Additionally, we conducted a large questionnaire survey among the municipalities of Greece to assess the existing situation regarding forest fire prevention. Therefore, a network connecting civil protection departments of municipalities was developed, based on an Internet platform, which acted also as a communication tool. Overall, we had feedback either online or offline from 125 municipalities across the country (representing more than one/third of the total municipalities of Greece). 23% of the municipalities have not compiled an action plan yet despite the fact that the 3013/2002 Act of the Greek National Law requires one. Moreover, existing action plans are predominantly catalogues and tables of information regarding authorised personnel and equipment. They lack important information, present no spatial data and display no prevention measures. Indeed, 85% of the municipalities that have action plans do not use risk maps and spatial data, which are of decisive importance for compiling the plans. 74% of the municipalities do not keep a record of forest fires. The jurisdiction area has been modified after the new administrative plan of Kallikratis in 2010 in 74% of the municipalities, however, local action plans were not adapted accordingly in 61% of these. The daily Fire Risk Map of the General Secretariat of Civil Protection has a key role, since 77% of the municipalities take additional measures in case of increased fire risk. According to the civil protection officials, existing action plans suffer from several major problems which emerge due to the fact: that there is no assessment on the fire hazard 67%, there is lack of personnel training 65%, new technologies are not incorporated or used 57% and there is a lack of a template for compiling an action plan 53%. The partnership between the University of Athens with the support of the private sector and the Union of Municipalities of Attica was held under the LIFE+ project "Local Authorities Alliance for Forest Fire Prevention - LIFE08/ENV/GR/000553 " which is implemented with the contribution of the LIFE financial instrument of the European Community.

  2. Cook It Up! A community-based cooking program for at-risk youth: overview of a food literacy intervention.

    PubMed

    Thomas, Heather Mc; Irwin, Jennifer D

    2011-11-15

    In Canada, there are limited occasions for youth, and especially at-risk youth, to participate in cooking programs. The paucity of these programs creates an opportunity for youth-focused cooking programs to be developed, implemented, and evaluated with the goal of providing invaluable life skills and food literacy to this potentially vulnerable group. Thus, an 18-month community-based cooking program for at-risk youth was planned and implemented to improve the development and progression of cooking skills and food literacy. This paper provides an overview of the rationale for and implementation of a cooking skills intervention for at-risk youth. The manuscript provides information about the process of planning and implementing the intervention as well as the evaluation plan. Results of the intervention will be presented elsewhere. Objectives of the intervention included the provision of applied food literacy and cooking skills education taught by local chefs and a Registered Dietitian, and augmented with fieldtrips to community farms to foster an appreciation and understanding of food, from 'gate to plate'. Eight at-risk youth (five girls and three boys, mean age = 14.6) completed the intervention as of November 2010. Pre-test cooking skills assessments were completed for all participants and post-test cooking skills assessments were completed for five of eight participants. Post intervention, five of eight participants completed in-depth interviews about their experience. The Cook It Up! program can provide an effective template for other agencies and researchers to utilize for enhancing existing programs or to create new applied cooking programs for relevant vulnerable populations. There is also a continued need for applied research in this area to reverse the erosion of cooking skills in Canadian society.

  3. Cook It Up! A community-based cooking program for at-risk youth: overview of a food literacy intervention

    PubMed Central

    2011-01-01

    Background In Canada, there are limited occasions for youth, and especially at-risk youth, to participate in cooking programs. The paucity of these programs creates an opportunity for youth-focused cooking programs to be developed, implemented, and evaluated with the goal of providing invaluable life skills and food literacy to this potentially vulnerable group. Thus, an 18-month community-based cooking program for at-risk youth was planned and implemented to improve the development and progression of cooking skills and food literacy. Findings This paper provides an overview of the rationale for and implementation of a cooking skills intervention for at-risk youth. The manuscript provides information about the process of planning and implementing the intervention as well as the evaluation plan. Results of the intervention will be presented elsewhere. Objectives of the intervention included the provision of applied food literacy and cooking skills education taught by local chefs and a Registered Dietitian, and augmented with fieldtrips to community farms to foster an appreciation and understanding of food, from 'gate to plate'. Eight at-risk youth (five girls and three boys, mean age = 14.6) completed the intervention as of November 2010. Pre-test cooking skills assessments were completed for all participants and post-test cooking skills assessments were completed for five of eight participants. Post intervention, five of eight participants completed in-depth interviews about their experience. Discussion The Cook It Up! program can provide an effective template for other agencies and researchers to utilize for enhancing existing programs or to create new applied cooking programs for relevant vulnerable populations. There is also a continued need for applied research in this area to reverse the erosion of cooking skills in Canadian society. PMID:22085523

  4. A simple running model with rolling contact and its role as a template for dynamic locomotion on a hexapod robot.

    PubMed

    Huang, Ke-Jung; Huang, Chun-Kai; Lin, Pei-Chun

    2014-10-07

    We report on the development of a robot's dynamic locomotion based on a template which fits the robot's natural dynamics. The developed template is a low degree-of-freedom planar model for running with rolling contact, which we call rolling spring loaded inverted pendulum (R-SLIP). Originating from a reduced-order model of the RHex-style robot with compliant circular legs, the R-SLIP model also acts as the template for general dynamic running. The model has a torsional spring and a large circular arc as the distributed foot, so during locomotion it rolls on the ground with varied equivalent linear stiffness. This differs from the well-known spring loaded inverted pendulum (SLIP) model with fixed stiffness and ground contact points. Through dimensionless steps-to-fall and return map analysis, within a wide range of parameter spaces, the R-SLIP model is revealed to have self-stable gaits and a larger stability region than that of the SLIP model. The R-SLIP model is then embedded as the reduced-order 'template' in a more complex 'anchor', the RHex-style robot, via various mapping definitions between the template and the anchor. Experimental validation confirms that by merely deploying the stable running gaits of the R-SLIP model on the empirical robot with simple open-loop control strategy, the robot can easily initiate its dynamic running behaviors with a flight phase and can move with similar body state profiles to those of the model, in all five testing speeds. The robot, embedded with the SLIP model but performing walking locomotion, further confirms the importance of finding an adequate template of the robot for dynamic locomotion.

  5. A survey of the satisfaction of patients who have undergone implant surgery with and without employing a computer-guided implant surgical template

    PubMed Central

    Youk, Shin-Young; Lee, Jee-Ho; Heo, Seong-Joo; Roh, Hyun-Ki; Park, Eun-Jin; Shin, Im Hee

    2014-01-01

    PURPOSE This study aims to investigate the degree of subjective pain and the satisfaction of patients who have undergone an implant treatment using a computer-guided template. MATERIALS AND METHODS A survey was conducted for 135 patients who have undergone implant surgery with and without the use of the computer-guided template during the period of 2012 and 2013 in university hospitals, dental hospitals and dental clinics that practiced implant surgery using the computer-guided template. Likert scale and VAS score were used in the survey questions, and the independent t-test and One-Way ANOVA were performed (α=.05). RESULTS The route that the subjects were introduced to the computer-guided implant surgery using a surgical template was mostly advices by dentists, and the most common reason for which they chose to undergo such surgery was that it was accurate and safe. Most of them gave an answer that they were willing to recommend it to others. The patients who have undergone the computer-guided implant surgery felt less pain during the operation and showed higher satisfaction than those who have undergone conventional implant surgery. Among the patients who have undergone computer-guided implant surgery, those who also had prior experience of surgery without a computer-guided template expressed higher satisfaction with the former (P<.05). CONCLUSION In this study, it could be seen that the patients who have undergone computer-guided implant surgery employing a surgical template felt less pain and had higher satisfaction than those with the conventional one, and the dentist's description could provide the confidence about the safety of surgery. PMID:25352962

  6. HDOCK: a web server for protein-protein and protein-DNA/RNA docking based on a hybrid strategy.

    PubMed

    Yan, Yumeng; Zhang, Di; Zhou, Pei; Li, Botong; Huang, Sheng-You

    2017-07-03

    Protein-protein and protein-DNA/RNA interactions play a fundamental role in a variety of biological processes. Determining the complex structures of these interactions is valuable, in which molecular docking has played an important role. To automatically make use of the binding information from the PDB in docking, here we have presented HDOCK, a novel web server of our hybrid docking algorithm of template-based modeling and free docking, in which cases with misleading templates can be rescued by the free docking protocol. The server supports protein-protein and protein-DNA/RNA docking and accepts both sequence and structure inputs for proteins. The docking process is fast and consumes about 10-20 min for a docking run. Tested on the cases with weakly homologous complexes of <30% sequence identity from five docking benchmarks, the HDOCK pipeline tied with template-based modeling on the protein-protein and protein-DNA benchmarks and performed better than template-based modeling on the three protein-RNA benchmarks when the top 10 predictions were considered. The performance of HDOCK became better when more predictions were considered. Combining the results of HDOCK and template-based modeling by ranking first of the template-based model further improved the predictive power of the server. The HDOCK web server is available at http://hdock.phys.hust.edu.cn/. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.

  7. Deconstructing the Polymerase Chain Reaction: Understanding and Correcting Bias Associated with Primer Degeneracies and Primer-Template Mismatches

    PubMed Central

    Green, Stefan J.; Venkatramanan, Raghavee; Naqib, Ankur

    2015-01-01

    The polymerase chain reaction (PCR) is sensitive to mismatches between primer and template, and mismatches can lead to inefficient amplification of targeted regions of DNA template. In PCRs in which a degenerate primer pool is employed, each primer can behave differently. Therefore, inefficiencies due to different primer melting temperatures within a degenerate primer pool, in addition to mismatches between primer binding sites and primers, can lead to a distortion of the true relative abundance of targets in the original DNA pool. A theoretical analysis indicated that a combination of primer-template and primer-amplicon interactions during PCR cycles 3–12 is potentially responsible for this distortion. To test this hypothesis, we developed a novel amplification strategy, entitled “Polymerase-exonuclease (PEX) PCR”, in which primer-template interactions and primer-amplicon interactions are separated. The PEX PCR method substantially and significantly improved the evenness of recovery of sequences from a mock community of known composition, and allowed for amplification of templates with introduced mismatches near the 3’ end of the primer annealing sites. When the PEX PCR method was applied to genomic DNA extracted from complex environmental samples, a significant shift in the observed microbial community was detected. Furthermore, the PEX PCR method provides a mechanism to identify which primers in a primer pool are annealing to target gDNA. Primer utilization patterns revealed that at high annealing temperatures in the PEX PCR method, perfect match annealing predominates, while at lower annealing temperatures, primers with up to four mismatches with templates can contribute substantially to amplification. The PEX PCR method is simple to perform, is limited to PCR mixes and a single exonuclease step which can be performed without reaction cleanup, and is recommended for reactions in which degenerate primer pools are used or when mismatches between primers and template are possible. PMID:25996930

  8. Accuracy of computer-guided implantation in a human cadaver model.

    PubMed

    Yatzkair, Gustavo; Cheng, Alice; Brodie, Stan; Raviv, Eli; Boyan, Barbara D; Schwartz, Zvi

    2015-10-01

    To examine the accuracy of computer-guided implantation using a human cadaver model with reduced experimental variability. Twenty-eight (28) dental implants representing 12 clinical cases were placed in four cadaver heads using a static guided implantation template. All planning and surgeries were performed by one clinician. All radiographs and measurements were performed by two examiners. The distance of the implants from buccal and lingual bone and mesial implant or tooth was analyzed at the apical and coronal levels, and measurements were compared to the planned values. No significant differences were seen between planned and implanted measurements. Average deviation of an implant from its planning radiograph was 0.8 mm, which is within the range of variability expected from CT analysis. Guided implantation can be used safely with a margin of error of 1 mm. © 2014 The Authors. Clinical Oral Implants Research Published by John Wiley & Sons Ltd.

  9. 77 FR 49485 - Agency Information Collection Activities: Proposed Information Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-16

    ... requirement for national banks and Federal savings associations titled, ``Company-Run Annual Stress Test... proposed information collection: Title: Company-Run Annual Stress Test Reporting Template and Documentation... stress tests \\2\\ and requires the primary financial regulatory agency \\3\\ of those financial companies to...

  10. International Space Station Payload Training Overview

    NASA Technical Reports Server (NTRS)

    Underwood, Deborah B.; Noneman, Steven R.; Sanchez, Julie N.

    2001-01-01

    This paper describes payload crew training-related activities performed by NASA and the U.S. Payload Developer (PD) community for the International Space Station (ISS) Program. It describes how payloads will be trained and the overall training planning and integration process. The overall concept, definition, and template for payload training are described. The roles and responsibilities of individuals, organizations, and groups involved are discussed. The facilities utilized during payload training and the primary processes and activities performed to plan, develop, implement, and administer payload training for ISS crews are briefly described. Areas of improvement to crew training processes that have been achieved or are currently being worked are identified.

  11. An easy-to-use word processing program for creating concept cards in psychology courses: a method for teachers.

    PubMed

    Abramson, Charles I; Robinson, Ellen Gray; Rice, Jessica; Burley, Jami; Bergman, Staci; Delougherty, Patricia; Reudy, Katherine

    2002-06-01

    We describe a template to create concept cards in psychology courses using a word processing program. Students create their own individualized cards, which have the look and feel of flashcards and retain the same self-testing and monitoring features. Students report the template is easy to use, that the cards help them focus their study behavior and employ critical thinking skills in learning class material. We offer several suggestions on how to use the cards.

  12. Database interfaces on NASA's heterogeneous distributed database system

    NASA Technical Reports Server (NTRS)

    Huang, Shou-Hsuan Stephen

    1987-01-01

    The purpose of Distributed Access View Integrated Database (DAVID) interface module (Module 9: Resident Primitive Processing Package) is to provide data transfer between local DAVID systems and resident Data Base Management Systems (DBMSs). The result of current research is summarized. A detailed description of the interface module is provided. Several Pascal templates were constructed. The Resident Processor program was also developed. Even though it is designed for the Pascal templates, it can be modified for templates in other languages, such as C, without much difficulty. The Resident Processor itself can be written in any programming language. Since Module 5 routines are not ready yet, there is no way to test the interface module. However, simulation shows that the data base access programs produced by the Resident Processor do work according to the specifications.

  13. Interplay of I-TASSER and QUARK for template-based and ab initio protein structure prediction in CASP10

    PubMed Central

    Zhang, Yang

    2014-01-01

    We develop and test a new pipeline in CASP10 to predict protein structures based on an interplay of I-TASSER and QUARK for both free-modeling (FM) and template-based modeling (TBM) targets. The most noteworthy observation is that sorting through the threading template pool using the QUARK-based ab initio models as probes allows the detection of distant-homology templates which might be ignored by the traditional sequence profile-based threading alignment algorithms. Further template assembly refinement by I-TASSER resulted in successful folding of two medium-sized FM targets with >150 residues. For TBM, the multiple threading alignments from LOMETS are, for the first time, incorporated into the ab initio QUARK simulations, which were further refined by I-TASSER assembly refinement. Compared with the traditional threading assembly refinement procedures, the inclusion of the threading-constrained ab initio folding models can consistently improve the quality of the full-length models as assessed by the GDT-HA and hydrogen-bonding scores. Despite the success, significant challenges still exist in domain boundary prediction and consistent folding of medium-size proteins (especially beta-proteins) for nonhomologous targets. Further developments of sensitive fold-recognition and ab initio folding methods are critical for solving these problems. PMID:23760925

  14. Interplay of I-TASSER and QUARK for template-based and ab initio protein structure prediction in CASP10.

    PubMed

    Zhang, Yang

    2014-02-01

    We develop and test a new pipeline in CASP10 to predict protein structures based on an interplay of I-TASSER and QUARK for both free-modeling (FM) and template-based modeling (TBM) targets. The most noteworthy observation is that sorting through the threading template pool using the QUARK-based ab initio models as probes allows the detection of distant-homology templates which might be ignored by the traditional sequence profile-based threading alignment algorithms. Further template assembly refinement by I-TASSER resulted in successful folding of two medium-sized FM targets with >150 residues. For TBM, the multiple threading alignments from LOMETS are, for the first time, incorporated into the ab initio QUARK simulations, which were further refined by I-TASSER assembly refinement. Compared with the traditional threading assembly refinement procedures, the inclusion of the threading-constrained ab initio folding models can consistently improve the quality of the full-length models as assessed by the GDT-HA and hydrogen-bonding scores. Despite the success, significant challenges still exist in domain boundary prediction and consistent folding of medium-size proteins (especially beta-proteins) for nonhomologous targets. Further developments of sensitive fold-recognition and ab initio folding methods are critical for solving these problems. Copyright © 2013 Wiley Periodicals, Inc.

  15. Mechanistic design data from ODOT instrumented pavement sites : phase II report.

    DOT National Transportation Integrated Search

    2017-03-01

    This investigation examined data obtained from three previously-instrumented pavement test sites in Oregon. Data processing algorithms and templates were developed for each test site that facilitated full processing of all the data to build databases...

  16. 3 CFR - Expanding America's Leadership in Wireless Innovation

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... results from the Networking and Information Technology Research and Development Program, shall publish an... in research, development, testing, and evaluation of technologies to enhance spectrum sharing and... templates governing the following: research, development, testing, and evaluation of spectrum sharing...

  17. Mechanistic design data from ODOT instrumented pavement sites : phase 1 report.

    DOT National Transportation Integrated Search

    2017-03-01

    This investigation examined data obtained from three previously-instrumented pavement test sites in Oregon. Data processing algorithms and templates were developed for each test site that facilitated full processing of all the data to build databases...

  18. Component-based target recognition inspired by human vision

    NASA Astrophysics Data System (ADS)

    Zheng, Yufeng; Agyepong, Kwabena

    2009-05-01

    In contrast with machine vision, human can recognize an object from complex background with great flexibility. For example, given the task of finding and circling all cars (no further information) in a picture, you may build a virtual image in mind from the task (or target) description before looking at the picture. Specifically, the virtual car image may be composed of the key components such as driver cabin and wheels. In this paper, we propose a component-based target recognition method by simulating the human recognition process. The component templates (equivalent to the virtual image in mind) of the target (car) are manually decomposed from the target feature image. Meanwhile, the edges of the testing image can be extracted by using a difference of Gaussian (DOG) model that simulates the spatiotemporal response in visual process. A phase correlation matching algorithm is then applied to match the templates with the testing edge image. If all key component templates are matched with the examining object, then this object is recognized as the target. Besides the recognition accuracy, we will also investigate if this method works with part targets (half cars). In our experiments, several natural pictures taken on streets were used to test the proposed method. The preliminary results show that the component-based recognition method is very promising.

  19. Bureau of Indian Affairs, Bureau of Indian Education State Performance Plan. Submitted February 1, 2011 (Resubmitted April 18, 2011). SPP Template-Part B

    ERIC Educational Resources Information Center

    Bureau of Indian Education, 2011

    2011-01-01

    The Bureau of Indian Education (BIE) funds schools located on 63 reservations in 23 states across the nation. Of the 183 schools, 59 are Bureau operated and 124 are tribally controlled. One-hundred and sixteen schools provide instructional programs, 55 provide instructional as well as boarding services and 12 peripheral dormitories provide only…

  20. Continuous Improvement of Team Assignments: Using a Web-based Tool and the Plan-Do-Check-Act Cycle in Design and Redesign

    ERIC Educational Resources Information Center

    Morgan, Shona D.; Stewart, Alice C.

    2017-01-01

    The purpose of this brief is twofold. First, it describes a useful template for business instructors to improve teamwork assignment design and efficacy; and second, it provides an example of how to use data collected and analyzed from a Web-based tool, Comprehensive Assessment of Team Member Effectiveness (CATME). Though CATME has been the subject…

  1. U.S. Department of the Interior, Bureau of Indian Education State Performance Plan. Submitted February 1, 2012 (Re-Submitted April 17, 2012). SPP Template-Part B

    ERIC Educational Resources Information Center

    Bureau of Indian Education, 2012

    2012-01-01

    The Bureau of Indian Education (BIE) funds schools located on 63 reservations in 23 states across the nation. Of the 183 schools, 59 are Bureau operated and 124 are tribally controlled. One-hundred and sixteen schools provide instructional programs, 55 provide instructional as well as boarding services and 12 peripheral dormitories provide only…

  2. The theory of planned behaviour explains intentions to use antiresorptive medication after a fragility fracture.

    PubMed

    Sale, Joanna E M; Cameron, Cathy; Thielke, Stephen; Meadows, Lynn; Senior, Kevin

    2017-06-01

    Our objective was to ascertain whether the Theory of Planned Behaviour (TPB) explains patient intentions to use antiresorptive medication after a fracture. A qualitative study was conducted with English-speaking members of the Canadian Osteoporosis Patient Network (COPN) who had sustained a fragility fracture at 50+ years of age and were not taking antiresorptive medication at the time of that fracture. Questions during a 1-h telephone interview were guided by the domains of the TPB: they addressed the antecedent constructs regarding antiresorptive medication (attitudes, subjective norms, and perceived behavioural control) as well as intentions regarding antiresorptive medication use. We created a coding template a priori based on the TPB domains and applied this template to the interview data. Twenty-six eligible participants (24 females, 2 males) aged 51-89 completed an interview. The TPB appeared to be predictive of intentions in 19 (73%) participants. In the majority of participants where the TPB did not appear to be predictive (57%), a positive attitude toward antiresorptive medication was the most important antecedent variable in determining intentions. The TPB appeared to be predictive of intentions to use antiresorptive medication among individuals who had experienced a fragility fracture. Attitudes towards medication were especially important.

  3. Constructing an Online Test Framework, Using the Example of a Sign Language Receptive Skills Test

    ERIC Educational Resources Information Center

    Haug, Tobias; Herman, Rosalind; Woll, Bencie

    2015-01-01

    This paper presents the features of an online test framework for a receptive skills test that has been adapted, based on a British template, into different sign languages. The online test includes features that meet the needs of the different sign language versions. Features such as usability of the test, automatic saving of scores, and score…

  4. TEMPLATES: Targeting Extremely Magnified Panchromatic Lensed Arcs and Their Extended Star formation

    NASA Astrophysics Data System (ADS)

    Spilker, Justin; Rigby, Jane R.; Vieira, Joaquin D.; TEMPLATES Team

    2018-06-01

    TEMPLATES is a JWST Early Release Science program designed to produce high signal-to-noise imaging and IFU spectroscopic data cubes for four gravitationally lensed galaxies at high redshift. The program will spatially resolve the star formation in galaxies across the peak of cosmic star formation in an extinction-robust manner. Lensing magnification pushes JWST to the highest spatial resolutions possible at these redshifts, to map the key spectral diagnostics of star formation and dust extinction: H-alpha, Pa-alpha, and 3.3um PAH emission within individual distant galaxies. Our targets are among the brightest, best-characterized lensed systems known, and include both UV-bright 'normal' galaxies and heavily dust-obscured submillimeter galaxies, at a range of stellar masses and luminosities. I will describe the scientific motivation for this program, detail the targeted galaxies, and describe the planned data products to be delivered to the community in advance of JWST Cycle 2.

  5. Business planning: a template for success.

    PubMed

    Dye, Judy

    2002-01-01

    Because managing a laboratory, or any health-care entity, is as much a business as a service, it is important for you to have a good grasp on how you can take opportunities from idea conception to implementation to assessment/revision. Regardless of the size of your proposed project, you need to consider a number of factors, among them: your history and what opportunities you can seize from your strengths and weaknesses; the overall business climate; anticipated costs; staff involvement; how you will market your project; and what measures to use to determine your success. Above all else, you need to set goals, both ultimate and intermediate, to instill focus, incentive, and a sense of achievement. The next time someone on your staff says, "Why don't we try that?," refer to this Template Topic. It can serve as a tool to help you determine whether you should try "that" and be the compass that helps guide your efforts.

  6. An optimised patient information sheet did not significantly increase recruitment or retention in a falls prevention study: an embedded randomised recruitment trial.

    PubMed

    Cockayne, Sarah; Fairhurst, Caroline; Adamson, Joy; Hewitt, Catherine; Hull, Robin; Hicks, Kate; Keenan, Anne-Maree; Lamb, Sarah E; Green, Lorraine; McIntosh, Caroline; Menz, Hylton B; Redmond, Anthony C; Rodgers, Sara; Torgerson, David J; Vernon, Wesley; Watson, Judith; Knapp, Peter; Rick, Jo; Bower, Peter; Eldridge, Sandra; Madurasinghe, Vichithranie W; Graffy, Jonathan

    2017-03-28

    Randomised controlled trials are generally regarded as the 'gold standard' experimental design to determine the effectiveness of an intervention. Unfortunately, many trials either fail to recruit sufficient numbers of participants, or recruitment takes longer than anticipated. The current embedded trial evaluates the effectiveness of optimised patient information sheets on recruitment of participants in a falls prevention trial. A three-arm, embedded randomised methodology trial was conducted within the National Institute for Health Research-funded REducing Falls with ORthoses and a Multifaceted podiatry intervention (REFORM) cohort randomised controlled trial. Routine National Health Service podiatry patients over the age of 65 were randomised to receive either the control patient information sheet (PIS) for the host trial or one of two optimised versions, a bespoke user-tested PIS or a template-developed PIS. The primary outcome was the proportion of patients in each group who went on to be randomised to the host trial. Six thousand and nine hundred patients were randomised 1:1:1 into the embedded trial. A total of 193 (2.8%) went on to be randomised into the main REFORM trial (control n = 62, template-developed n = 68; bespoke user-tested n = 63). Information sheet allocation did not improve recruitment to the trial (odds ratios for the three pairwise comparisons: template vs control 1.10 (95% CI 0.77-1.56, p = 0.60); user-tested vs control 1.01 (95% CI 0.71-1.45, p = 0.94); and user-tested vs template 0.92 (95% CI 0.65-1.31, p = 0.65)). This embedded methodology trial has demonstrated limited evidence as to the benefit of using optimised information materials on recruitment and retention rates in the REFORM study. International Standard Randomised Controlled Trials Number registry, ISRCTN68240461 . Registered on 01 July 2011.

  7. 78 FR 51272 - Agency Information Collection Activities: Revision of an Approved Information Collection; Comment...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-20

    ... requirement for national banks and Federal savings associations titled, ``Company-Run Annual Stress Test...://www.occ.treas.gov/tools-forms/forms/bank-operations/stress-test-reporting.html ). SUPPLEMENTARY...: Title: Company-Run Annual Stress Test Reporting Template and Documentation for Covered Institutions with...

  8. An eFTD-VP framework for efficiently generating patient-specific anatomically detailed facial soft tissue FE mesh for craniomaxillofacial surgery simulation

    PubMed Central

    Zhang, Xiaoyan; Kim, Daeseung; Shen, Shunyao; Yuan, Peng; Liu, Siting; Tang, Zhen; Zhang, Guangming; Zhou, Xiaobo; Gateno, Jaime

    2017-01-01

    Accurate surgical planning and prediction of craniomaxillofacial surgery outcome requires simulation of soft tissue changes following osteotomy. This can only be achieved by using an anatomically detailed facial soft tissue model. The current state-of-the-art of model generation is not appropriate to clinical applications due to the time-intensive nature of manual segmentation and volumetric mesh generation. The conventional patient-specific finite element (FE) mesh generation methods are to deform a template FE mesh to match the shape of a patient based on registration. However, these methods commonly produce element distortion. Additionally, the mesh density for patients depends on that of the template model. It could not be adjusted to conduct mesh density sensitivity analysis. In this study, we propose a new framework of patient-specific facial soft tissue FE mesh generation. The goal of the developed method is to efficiently generate a high-quality patient-specific hexahedral FE mesh with adjustable mesh density while preserving the accuracy in anatomical structure correspondence. Our FE mesh is generated by eFace template deformation followed by volumetric parametrization. First, the patient-specific anatomically detailed facial soft tissue model (including skin, mucosa, and muscles) is generated by deforming an eFace template model. The adaptation of the eFace template model is achieved by using a hybrid landmark-based morphing and dense surface fitting approach followed by a thin-plate spline interpolation. Then, high-quality hexahedral mesh is constructed by using volumetric parameterization. The user can control the resolution of hexahedron mesh to best reflect clinicians’ need. Our approach was validated using 30 patient models and 4 visible human datasets. The generated patient-specific FE mesh showed high surface matching accuracy, element quality, and internal structure matching accuracy. They can be directly and effectively used for clinical simulation of facial soft tissue change. PMID:29027022

  9. WE-DE-201-08: Multi-Source Rotating Shield Brachytherapy Apparatus for Prostate Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dadkhah, H; Wu, X; Kim, Y

    Purpose: To introduce a novel multi-source rotating shield brachytherapy (RSBT) apparatus for the precise simultaneous angular and linear positioning of all partially-shielded 153Gd radiation sources in interstitial needles for treating prostate cancer. The mechanism is designed to lower the detrimental dose to healthy tissues, the urethra in particular, relative to conventional high-dose-rate brachytherapy (HDR-BT) techniques. Methods: Following needle implantation, the delivery system is docked to the patient template. Each needle is coupled to a multi-source afterloader catheter by a connector passing through a shaft. The shafts are rotated by translating a moving template between two stationary templates. Shaft walls asmore » well as moving template holes are threaded such that the resistive friction produced between the two parts exerts enough force on the shafts to bring about the rotation. Rotation of the shaft is then transmitted to the shielded source via several keys. Thus, shaft angular position is fully correlated with the position of the moving template. The catheter angles are simultaneously incremented throughout treatment as needed, and only a single 360° rotation of all catheters is needed for a full treatment. For each rotation angle, source depth in each needle is controlled by a multi-source afterloader, which is proposed as an array of belt-driven linear actuators, each of which drives a source wire. Results: Optimized treatment plans based on Monte Carlo dose calculations demonstrated RSBT with the proposed apparatus reduced urethral D{sub 1cc} below that of conventional HDR-BT by 35% for urethral dose gradient volume within 3 mm of the urethra surface. Treatment time to deliver 20 Gy with multi-source RSBT apparatus using nineteen 62.4 GBq {sup 153}Gd sources is 117 min. Conclusions: The proposed RSBT delivery apparatus in conjunction with multiple nitinol catheter-mounted platinum-shielded {sup 153}Gd sources enables a mechanically feasible urethra-sparing treatment technique for prostate cancer in a clinically reasonable timeframe.« less

  10. An eFTD-VP framework for efficiently generating patient-specific anatomically detailed facial soft tissue FE mesh for craniomaxillofacial surgery simulation.

    PubMed

    Zhang, Xiaoyan; Kim, Daeseung; Shen, Shunyao; Yuan, Peng; Liu, Siting; Tang, Zhen; Zhang, Guangming; Zhou, Xiaobo; Gateno, Jaime; Liebschner, Michael A K; Xia, James J

    2018-04-01

    Accurate surgical planning and prediction of craniomaxillofacial surgery outcome requires simulation of soft tissue changes following osteotomy. This can only be achieved by using an anatomically detailed facial soft tissue model. The current state-of-the-art of model generation is not appropriate to clinical applications due to the time-intensive nature of manual segmentation and volumetric mesh generation. The conventional patient-specific finite element (FE) mesh generation methods are to deform a template FE mesh to match the shape of a patient based on registration. However, these methods commonly produce element distortion. Additionally, the mesh density for patients depends on that of the template model. It could not be adjusted to conduct mesh density sensitivity analysis. In this study, we propose a new framework of patient-specific facial soft tissue FE mesh generation. The goal of the developed method is to efficiently generate a high-quality patient-specific hexahedral FE mesh with adjustable mesh density while preserving the accuracy in anatomical structure correspondence. Our FE mesh is generated by eFace template deformation followed by volumetric parametrization. First, the patient-specific anatomically detailed facial soft tissue model (including skin, mucosa, and muscles) is generated by deforming an eFace template model. The adaptation of the eFace template model is achieved by using a hybrid landmark-based morphing and dense surface fitting approach followed by a thin-plate spline interpolation. Then, high-quality hexahedral mesh is constructed by using volumetric parameterization. The user can control the resolution of hexahedron mesh to best reflect clinicians' need. Our approach was validated using 30 patient models and 4 visible human datasets. The generated patient-specific FE mesh showed high surface matching accuracy, element quality, and internal structure matching accuracy. They can be directly and effectively used for clinical simulation of facial soft tissue change.

  11. A genotype independent, full-genome reverse-transcription protocol for HCV genotyping and resistance testing.

    PubMed

    Walker, Andreas; Bergmann, Matthias; Camdereli, Jennifer; Kaiser, Rolf; Lübke, Nadine; Timm, Jörg

    2017-06-01

    HCV treatment options and cure rates have tremendously increased in the last decade. Although a pan-genotype HCV treatment has recently been approved, most DAA therapies are still genotype specific. Resistance-associated variants (RAVs) can limit the efficacy of DAA therapy and are associated with increased risk for therapy failure. With the approval of DAA regimens that recommend resistance testing prior to therapy, correct assessment of the genotype and testing for viruses with RAVs is clinically relevant. However, genotyping and resistance testing is generally done in costly and laborious separate reactions. The aim of the study was to establish a genotype-independent full-genome reverse transcription protocol to generate a template for both genotyping and resistance testing and to implement it into our routine diagnostic setup. The complete HCV genome was reverse transcribed with a pan-genotype primer binding at the 3'end of the viral RNA. This cDNA served as template for transcription of the genotyping amplicon in the core region as well as for the resistance testing of NS3, NS5A, and NS5B. With the established RT-protocol the HCV core region was successfully amplified and genotyped from 124 out of 125 (99.2%) HCV-positive samples. The amplification efficiency of RAV containing regions in NS3, NS5A, NS5B was 96.2%, 96.6% and 94.4%, respectively. We developed a method for HCV full-genome cDNA synthesis and implemented it into a routine diagnostic setup. This cDNA can be used as template for genotyping amplicons covering the core or NS5B region as well as for resistance testing amplicons in NS3, NS5A and NS5B. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Implementing a Structured Reporting Initiative Using a Collaborative Multistep Approach.

    PubMed

    Goldberg-Stein, Shlomit; Walter, William R; Amis, E Stephen; Scheinfeld, Meir H

    To describe the successful implementation of a structured reporting initiative in a large urban academic radiology department. We describe our process, compromises, and top 10 lessons learned in overhauling traditional reporting practices and comprehensively implementing structured reporting at our institution. To achieve our goals, we took deliberate steps toward consensus building, undertook multistep template refinement, and achieved close collaboration with the technical staff, department coders, and hospital information technologists. Following institutional review board exemption, we audited radiologist compliance by evaluating 100 consecutive cases of 12 common examination types. Fisher exact test was applied to determine significance of association between trainee initial report drafting and template compliance. We produced and implemented structured reporting templates for 95% of all departmental computed tomography, magnetic resonance, and ultrasound examinations. Structured templates include specialized reports adhering to the American College of Radiology's Reporting and Data Systems (ACR's RADS) recommendations (eg, Lung-RADS and Li-RADS). We attained 94% radiologist compliance within 2 years, without any financial incentives. We provide a blueprint of how to successfully achieve structured reporting using a collaborative multistep approach. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Micelle-template synthesis of hollow silica spheres for improving water vapor permeability of waterborne polyurethane membrane

    PubMed Central

    Bao, Yan; Wang, Tong; Kang, Qiaoling; Shi, Chunhua; Ma, Jianzhong

    2017-01-01

    Hollow silica spheres (HSS) with special interior spaces, high specific surface area and excellent adsorption and permeability performance were synthesized via micelle-template method using cetyl trimethyl ammonium bromide (CTAB) micelles as soft template and tetraethoxysilane (TEOS) as silica precursor. SEM, TEM, FT-IR, XRD, DLS and BET-BJH were carried out to characterize the morphology and structure of as-obtained samples. The results demonstrated that the samples were amorphous with a hollow structure and huge specific surface area. The growth of HSS was an inward-growth mechanism along template. Notably, we have provided a new and interesting fundamental principle for HSS materials by precisely controlling the ethanol-to-water volume ratio. In addition, the as-obtained HSS were mixed with waterborne polyurethane (WPU) to prepare WPU/HSS composite membrane. Various characterizations (SEM, TEM, FT-IR and TGA) revealed the morphology, polydispersity and adherence between HSS and WPU. Performance tests showed that the introduction of HSS can improve the water vapor permeability of composite membrane, promoting its water resistance and mechanical performance at the same time. PMID:28429740

  14. Micelle-template synthesis of hollow silica spheres for improving water vapor permeability of waterborne polyurethane membrane

    NASA Astrophysics Data System (ADS)

    Bao, Yan; Wang, Tong; Kang, Qiaoling; Shi, Chunhua; Ma, Jianzhong

    2017-04-01

    Hollow silica spheres (HSS) with special interior spaces, high specific surface area and excellent adsorption and permeability performance were synthesized via micelle-template method using cetyl trimethyl ammonium bromide (CTAB) micelles as soft template and tetraethoxysilane (TEOS) as silica precursor. SEM, TEM, FT-IR, XRD, DLS and BET-BJH were carried out to characterize the morphology and structure of as-obtained samples. The results demonstrated that the samples were amorphous with a hollow structure and huge specific surface area. The growth of HSS was an inward-growth mechanism along template. Notably, we have provided a new and interesting fundamental principle for HSS materials by precisely controlling the ethanol-to-water volume ratio. In addition, the as-obtained HSS were mixed with waterborne polyurethane (WPU) to prepare WPU/HSS composite membrane. Various characterizations (SEM, TEM, FT-IR and TGA) revealed the morphology, polydispersity and adherence between HSS and WPU. Performance tests showed that the introduction of HSS can improve the water vapor permeability of composite membrane, promoting its water resistance and mechanical performance at the same time.

  15. Micelle-template synthesis of hollow silica spheres for improving water vapor permeability of waterborne polyurethane membrane.

    PubMed

    Bao, Yan; Wang, Tong; Kang, Qiaoling; Shi, Chunhua; Ma, Jianzhong

    2017-04-21

    Hollow silica spheres (HSS) with special interior spaces, high specific surface area and excellent adsorption and permeability performance were synthesized via micelle-template method using cetyl trimethyl ammonium bromide (CTAB) micelles as soft template and tetraethoxysilane (TEOS) as silica precursor. SEM, TEM, FT-IR, XRD, DLS and BET-BJH were carried out to characterize the morphology and structure of as-obtained samples. The results demonstrated that the samples were amorphous with a hollow structure and huge specific surface area. The growth of HSS was an inward-growth mechanism along template. Notably, we have provided a new and interesting fundamental principle for HSS materials by precisely controlling the ethanol-to-water volume ratio. In addition, the as-obtained HSS were mixed with waterborne polyurethane (WPU) to prepare WPU/HSS composite membrane. Various characterizations (SEM, TEM, FT-IR and TGA) revealed the morphology, polydispersity and adherence between HSS and WPU. Performance tests showed that the introduction of HSS can improve the water vapor permeability of composite membrane, promoting its water resistance and mechanical performance at the same time.

  16. Characterization of molecularly imprinted polymers using a new polar solvent titration method.

    PubMed

    Song, Di; Zhang, Yagang; Geer, Michael F; Shimizu, Ken D

    2014-07-01

    A new method of characterizing molecularly imprinted polymers (MIPs) was developed and tested, which provides a more accurate means of identifying and measuring the molecular imprinting effect. In the new polar solvent titration method, a series of imprinted and non-imprinted polymers were prepared in solutions containing increasing concentrations of a polar solvent. The polar solvent additives systematically disrupted the templation and monomer aggregation processes in the prepolymerization solutions, and the extent of disruption was captured by the polymerization process. The changes in binding capacity within each series of polymers were measured, providing a quantitative assessment of the templation and monomer aggregation processes in the imprinted and non-imprinted polymers. The new method was tested using three different diphenyl phosphate imprinted polymers made using three different urea functional monomers. Each monomer had varying efficiencies of templation and monomer aggregation. The new MIP characterization method was found to have several advantages. To independently verify the new characterization method, the MIPs were also characterized using traditional binding isotherm analyses. The two methods appeared to give consistent conclusions. First, the polar solvent titration method is less susceptible to false positives in identifying the imprinting effect. Second, the method is able to differentiate and quantify changes in binding capacity, as measured at a fixed guest and polymer concentration, arising from templation or monomer aggregation processes in the prepolymerization solution. Third, the method was also easy to carry out, taking advantage of the ease of preparing MIPs. Copyright © 2014 John Wiley & Sons, Ltd.

  17. How to Choose the Suitable Template for Homology Modelling of GPCRs: 5-HT7 Receptor as a Test Case.

    PubMed

    Shahaf, Nir; Pappalardo, Matteo; Basile, Livia; Guccione, Salvatore; Rayan, Anwar

    2016-09-01

    G protein-coupled receptors (GPCRs) are a super-family of membrane proteins that attract great pharmaceutical interest due to their involvement in almost every physiological activity, including extracellular stimuli, neurotransmission, and hormone regulation. Currently, structural information on many GPCRs is mainly obtained by the techniques of computer modelling in general and by homology modelling in particular. Based on a quantitative analysis of eighteen antagonist-bound, resolved structures of rhodopsin family "A" receptors - also used as templates to build 153 homology models - it was concluded that a higher sequence identity between two receptors does not guarantee a lower RMSD between their structures, especially when their pair-wise sequence identity (within trans-membrane domain and/or in binding pocket) lies between 25 % and 40 %. This study suggests that we should consider all template receptors having a sequence identity ≤50 % with the query receptor. In fact, most of the GPCRs, compared to the currently available resolved structures of GPCRs, fall within this range and lack a correlation between structure and sequence. When testing suitability for structure-based drug design, it was found that choosing as a template the most similar resolved protein, based on sequence resemblance only, led to unsound results in many cases. Molecular docking analyses were carried out, and enrichment factors as well as attrition rates were utilized as criteria for assessing suitability for structure-based drug design. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Automated interpretation of ventilation-perfusion lung scintigrams for the diagnosis of pulmonary embolism using artificial neural networks.

    PubMed

    Holst, H; Aström, K; Järund, A; Palmer, J; Heyden, A; Kahl, F; Tägil, K; Evander, E; Sparr, G; Edenbrandt, L

    2000-04-01

    The purpose of this study was to develop a completely automated method for the interpretation of ventilation-perfusion (V-P) lung scintigrams used in the diagnosis of pulmonary embolism. An artificial neural network was trained for the diagnosis of pulmonary embolism using 18 automatically obtained features from each set of V-P scintigrams. The techniques used to process the images included their alignment to templates, the construction of quotient images based on the ventilation and perfusion images, and the calculation of measures describing V-P mismatches in the quotient images. The templates represented lungs of normal size and shape without any pathological changes. Images that could not be properly aligned to the templates were detected and excluded automatically. After exclusion of those V-P scintigrams not properly aligned to the templates, 478 V-P scintigrams remained in a training group of consecutive patients with suspected pulmonary embolism, and a further 87 V-P scintigrams formed a separate test group comprising patients who had undergone pulmonary angiography. The performance of the neural network, measured as the area under the receiver operating characteristic curve, was 0.87 (95% confidence limits 0.82-0.92) in the training group and 0.79 (0.69-0.88) in the test group. It is concluded that a completely automated method can be used for the interpretation of V-P scintigrams. The performance of this method is similar to others previously presented, whereby features were extracted manually.

  19. Cryo-Milling and the Hydrogen Storage Properties of NaAlH4

    NASA Astrophysics Data System (ADS)

    Feller, Kevin; Dobbins, Tabbetha

    2013-03-01

    High energy ball milling of metal hydrides is a common way to both introduce catalysts (e.g. TiCl3) and to simultaneously increase the surface area. Both catalysis and increased surface area improve hydrogen storage capacity of the material. Nanostructuring of hydrides by depositing them into mesoporous templates (such as anodized alumina, MOFs, and SBA-15) has become a common way to increase surface area. However, the mesoporous template does not add hydrogen storage capacity--and thus, tends to decreased overall storage weight percent for the nanostructured hydride material. As with most materials, hydrides become brittle at low temperatures and will tend to fracture more readily. We will process Sodium Aluminum Hydride (NaAlH4) using cryogenic high energy ball milling using an in-house modified chamber SPEX Certiprep M8000 mixer/mill in order to gain a nanostructured hydride without mesoporous template material. Details of the modified mixer mill design will be presented. Ultimately, our planned future work is to study the resultant material using x-ray diffraction (Scherrer method for crystallite size), absorption/desorption temperature programmed desorption (TPD), and ultrasmall-angle x-ray scattering (USAXS) microstructural quantification to understand the role of cryomilling on enhancing the material's ability to store (and release) hydrogen.

  20. Improving the Capacity of Sodium Ion Battery Using a Virus-Templated Nanostructured Composite Cathode

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moradi, M; Li, Z; Qi, JF

    In this work we investigated an energy-efficient biotemplated route to synthesize nanostructured FePO4 for sodium-based batteries. Self-assembled M13 viruses and single wall carbon nanotubes (SWCNTs) have been used as a template to grow amorphous FePO4 nanoparticles at room temperature (the active composite is denoted as Bio-FePO4-CNT) to enhance the electronic conductivity of the active material. Preliminary tests demonstrate a discharge capacity as high as 166 mAh/g at C/10 rate, corresponding to composition Na0.9FePO4, which along with higher C-rate tests show this material to have the highest capacity and power performance reported for amorphous FePO4 electrodes to date.

  1. Development and evaluation of a clinical model for lung cancer patients using stereotactic body radiotherapy (SBRT) within a knowledge-based algorithm for treatment planning.

    PubMed

    Chin Snyder, Karen; Kim, Jinkoo; Reding, Anne; Fraser, Corey; Gordon, James; Ajlouni, Munther; Movsas, Benjamin; Chetty, Indrin J

    2016-11-08

    The purpose of this study was to describe the development of a clinical model for lung cancer patients treated with stereotactic body radiotherapy (SBRT) within a knowledge-based algorithm for treatment planning, and to evaluate the model performance and applicability to different planning techniques, tumor locations, and beam arrangements. 105 SBRT plans for lung cancer patients previously treated at our institution were included in the development of the knowledge-based model (KBM). The KBM was trained with a combination of IMRT, VMAT, and 3D CRT techniques. Model performance was validated with 25 cases, for both IMRT and VMAT. The full KBM encompassed lesions located centrally vs. peripherally (43:62), upper vs. lower (62:43), and anterior vs. posterior (60:45). Four separate sub-KBMs were created based on tumor location. Results were compared with the full KBM to evaluate its robustness. Beam templates were used in conjunction with the optimizer to evaluate the model's ability to handle suboptimal beam placements. Dose differences to organs-at-risk (OAR) were evaluated between the plans gener-ated by each KBM. Knowledge-based plans (KBPs) were comparable to clinical plans with respect to target conformity and OAR doses. The KBPs resulted in a lower maximum spinal cord dose by 1.0 ± 1.6 Gy compared to clinical plans, p = 0.007. Sub-KBMs split according to tumor location did not produce significantly better DVH estimates compared to the full KBM. For central lesions, compared to the full KBM, the peripheral sub-KBM resulted in lower dose to 0.035 cc and 5 cc of the esophagus, both by 0.4Gy ± 0.8Gy, p = 0.025. For all lesions, compared to the full KBM, the posterior sub-KBM resulted in higher dose to 0.035 cc, 0.35 cc, and 1.2 cc of the spinal cord by 0.2 ± 0.4Gy, p = 0.01. Plans using template beam arrangements met target and OAR criteria, with an increase noted in maximum heart dose (1.2 ± 2.2Gy, p = 0.01) and GI (0.2 ± 0.4, p = 0.01) for the nine-field plans relative to KBPs planned with custom beam angles. A knowledge-based model for lung SBRT consisting of multiple treatment modalities and lesion loca-tions produced comparable plan quality to clinical plans. With proper training and validation, a robust KBM can be created that encompasses both IMRT and VMAT techniques, as well as different lesion locations. © 2016 The Authors.

  2. Computational Planning in Facial Surgery.

    PubMed

    Zachow, Stefan

    2015-10-01

    This article reflects the research of the last two decades in computational planning for cranio-maxillofacial surgery. Model-guided and computer-assisted surgery planning has tremendously developed due to ever increasing computational capabilities. Simulators for education, planning, and training of surgery are often compared with flight simulators, where maneuvers are also trained to reduce a possible risk of failure. Meanwhile, digital patient models can be derived from medical image data with astonishing accuracy and thus can serve for model surgery to derive a surgical template model that represents the envisaged result. Computerized surgical planning approaches, however, are often still explorative, meaning that a surgeon tries to find a therapeutic concept based on his or her expertise using computational tools that are mimicking real procedures. Future perspectives of an improved computerized planning may be that surgical objectives will be generated algorithmically by employing mathematical modeling, simulation, and optimization techniques. Planning systems thus act as intelligent decision support systems. However, surgeons can still use the existing tools to vary the proposed approach, but they mainly focus on how to transfer objectives into reality. Such a development may result in a paradigm shift for future surgery planning. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  3. Simulation, optimization and testing of a novel high spatial resolution X-ray imager based on Zinc Oxide nanowires in Anodic Aluminium Oxide membrane using Geant4

    NASA Astrophysics Data System (ADS)

    Esfandi, F.; Saramad, S.

    2015-07-01

    In this work, a new generation of scintillator based X-ray imagers based on ZnO nanowires in Anodized Aluminum Oxide (AAO) nanoporous template is characterized. The optical response of ordered ZnO nanowire arrays in porous AAO template under low energy X-ray illumination is simulated by the Geant4 Monte Carlo code and compared with experimental results. The results show that for 10 keV X-ray photons, by considering the light guiding properties of zinc oxide inside the AAO template and suitable selection of detector thickness and pore diameter, the spatial resolution less than one micrometer and the detector detection efficiency of 66% are accessible. This novel nano scintillator detector can have many advantages for medical applications in the future.

  4. Quantitative template for subtyping primary progressive aphasia.

    PubMed

    Mesulam, Marsel; Wieneke, Christina; Rogalski, Emily; Cobia, Derin; Thompson, Cynthia; Weintraub, Sandra

    2009-12-01

    The syndrome of primary progressive aphasia (PPA) is diagnosed when a gradual failure of word usage or comprehension emerges as the principal feature of a neurodegenerative disease. To provide a quantitative algorithm for classifying PPA into agrammatic (PPA-G), semantic (PPA-S), and logopenic (PPA-L) variants, each of which is known to have a different probability of association with Alzheimer disease vs frontotemporal lobar degeneration. Prospective study. University medical center. Sixteen consecutively enrolled patients with PPA who underwent neuropsychological testing and magnetic resonance imaging recruited nationally in the United States as part of a longitudinal study. A 2-dimensional template that reflects performance on tests of syntax (Northwestern Anagram Test) and lexical semantics (Peabody Picture Vocabulary Test-Fourth Edition) classified all 16 patients in concordance with a clinical diagnosis that had been made before the administration of quantitative tests. All 3 PPA subtypes had distinctly asymmetrical atrophy of the left perisylvian language network. Each subtype also had distinctive peak atrophy sites: PPA-G in the inferior frontal gyrus (Broca area), PPA-S in the anterior temporal lobe, and PPA-L in Brodmann area 37. Once an accurate root diagnosis of PPA is made, subtyping can be quantitatively guided using a 2-dimensional template based on orthogonal tasks of grammatical competence and word comprehension. Although the choice of tasks and the precise cutoff levels may need to be adjusted to fit linguistic and educational backgrounds, these 16 patients demonstrate the feasibility of using a simple algorithm for clinicoanatomical classification in PPA. Prospective studies will show whether this subtyping can improve clinical prediction of the underlying neuropathologic condition.

  5. QUANTITATIVE TEMPLATE FOR SUBTYPING PRIMARY PROGRESSIVE APHASIA

    PubMed Central

    Mesulam, Marsel; Wieneke, Christina; Rogalski, Emily; Cobia, Derin; Thompson, Cynthia; Weintraub, Sandra

    2009-01-01

    Objective To provide a quantitative algorithm for classifying primary progressive aphasia (PPA) into agrammatic (PPA-G), semantic (PPA-S) and logopenic (PPA-L) variants, each of which is known to have a different probability of association with Alzheimer’s disease (AD) versus frontotemporal lobar degeneration (FTLD). Design Prospectively and consecutively enrolled 16 PPA patients tested with neuropsychological instruments and magnetic resonance imaging (MRI). Setting University medical center. Participants PPA patients recruited nationally in the USA as part of a longitudinal study. Results A two-dimensional template, reflecting performance on tests of syntax (Northwestern Anagram Test) and lexical semantics (Peabody Picture Vocabulary Test), classified all 16 patients in concordance with a clinical diagnosis that had been made prior to the administration of the quantitative tests. All three subtypes had distinctly asymmetrical atrophy of the left perisylvian language network. Each subtype also had distinctive peak atrophy sites. Only PPA-G had peak atrophy in the IFG (Broca’s area), only PPA-S had peak atrophy in the anterior temporal lobe, and only PPA-L had peak atrophy in area 37. Conclusions Once an accurate root diagnosis of PPA is made, subtyping can be quantitatively guided using a two-dimensional template based on orthogonal tasks of grammatical competence and word comprehension. Although the choice of tasks and precise cut-off levels may evolve in time, this set of 16 patients demonstrates the feasibility of using a simple algorithm for clinico-anatomical classification in PPA. Prospective studies will show whether this suptyping can improve the clinical prediction of underlying neuropathology. PMID:20008661

  6. Template-based automatic breast segmentation on MRI by excluding the chest region

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, Muqing; Chen, Jeon-Hor; Wang, Xiaoyong

    2013-12-15

    Purpose: Methods for quantification of breast density on MRI using semiautomatic approaches are commonly used. In this study, the authors report on a fully automatic chest template-based method. Methods: Nonfat-suppressed breast MR images from 31 healthy women were analyzed. Among them, one case was randomly selected and used as the template, and the remaining 30 cases were used for testing. Unlike most model-based breast segmentation methods that use the breast region as the template, the chest body region on a middle slice was used as the template. Within the chest template, three body landmarks (thoracic spine and bilateral boundary ofmore » the pectoral muscle) were identified for performing the initial V-shape cut to determine the posterior lateral boundary of the breast. The chest template was mapped to each subject's image space to obtain a subject-specific chest model for exclusion. On the remaining image, the chest wall muscle was identified and excluded to obtain clean breast segmentation. The chest and muscle boundaries determined on the middle slice were used as the reference for the segmentation of adjacent slices, and the process continued superiorly and inferiorly until all 3D slices were segmented. The segmentation results were evaluated by an experienced radiologist to mark voxels that were wrongly included or excluded for error analysis. Results: The breast volumes measured by the proposed algorithm were very close to the radiologist's corrected volumes, showing a % difference ranging from 0.01% to 3.04% in 30 tested subjects with a mean of 0.86% ± 0.72%. The total error was calculated by adding the inclusion and the exclusion errors (so they did not cancel each other out), which ranged from 0.05% to 6.75% with a mean of 3.05% ± 1.93%. The fibroglandular tissue segmented within the breast region determined by the algorithm and the radiologist were also very close, showing a % difference ranging from 0.02% to 2.52% with a mean of 1.03% ± 1.03%. The total error by adding the inclusion and exclusion errors ranged from 0.16% to 11.8%, with a mean of 2.89% ± 2.55%. Conclusions: The automatic chest template-based breast MRI segmentation method worked well for cases with different body and breast shapes and different density patterns. Compared to the radiologist-established truth, the mean difference in segmented breast volume was approximately 1%, and the total error by considering the additive inclusion and exclusion errors was approximately 3%. This method may provide a reliable tool for MRI-based segmentation of breast density.« less

  7. Problem-Solving Test: Catalytic Activities of a Human Nuclear Enzyme

    ERIC Educational Resources Information Center

    Szeberenyi, Jozsef

    2011-01-01

    Terms to be familiar with before you start to solve the test: ion exchange chromatography, polynucleotides, oligonucleotides, radioactive labeling, template, primer, DNA polymerase, reverse transcriptase, helicase, nucleoside triphosphates, nucleoside diphosphates, nucleoside monophosphates, nucleosides, 5'-end and 3'-end, bacteriophage,…

  8. The DoD Enterprise Model. Volume 1. Strategic Activity and Data Models

    DTIC Science & Technology

    1994-01-01

    Provide Administrative Services: Inform & Advise provides explanations and expert opinions to people on such matters as health benefits , legal rights...level functional template for all DoD Corporate Information Management (CIM) initiatives. Major Defense activities have already benefitted from using...evaluating plan performance "• DvWm9 C"S" of Acto (e.g., occupational safety and health , "• De 10 Fl environmental protection, technology transfer

  9. The simplest acquisition protocol is sometimes the best protocol: performing and learning a 1:2 bimanual coordination task.

    PubMed

    Panzer, Stefan; Kennedy, Deanna; Wang, Chaoyi; Shea, Charles H

    2018-02-01

    An experiment was conducted to determine if the performance and learning of a multi-frequency (1:2) coordination pattern between the limbs are enhanced when a model is provided prior to each acquisition trial. Research has indicated very effective performance of a wide variety of bimanual coordination tasks when Lissajous plots with goal templates are provided, but this research has also found that participants become dependent on this information and perform quite poorly when it is withdrawn. The present experiment was designed to test three forms of modeling (Lissajous with template, Lissajous without template, and limb model), but in each situations, the model was presented prior to practice and not available during the performance of the task. This was done to decrease dependency on the model and increase the development of an internal reference of correctness that could be applied on test trials. A control condition was also collected, where a metronome was used to guide the movement. Following less than 7 min of practice, participants in the three modeling conditions performed the first test block very effectively; however, performance of the control condition was quite poor. Note that Test 1 was performed under the same conditions as used during acquisition. Test 2 was conducted with no augmented information provided prior to or during the performance of the task. Only participants in the limb model condition were able to maintain performance on Test 2. The findings suggest that a very simple intuitive display can provide the necessary information to form an effective internal representation of the coordination pattern which can be used guide performance when the augmented display is withdrawn.

  10. Case-mix adjustment and enabled reporting of the health care experiences of adults with disabilities.

    PubMed

    Palsbo, Susan E; Diao, Guoqing; Palsbo, Gregory A; Tang, Liansheng; Rosenberger, William F; Mastal, Margaret F

    2010-09-01

    To develop activity limitation clusters for case-mix adjustment of health care ratings and as a population profiler, and to develop a cognitively accessible report of statistically reliable quality and access measures comparing the health care experiences of adults with and without disabilities, within and across health delivery organizations. Observational study. Three California Medicaid health care organizations. Adults (N = 1086) of working age enrolled for at least 1 year in Medicaid because of disability. Not applicable. Principal components analysis created 4 clusters of activity limitations that we used to characterize case mix. We identified and calculated 28 quality measures using responses from a proposed enabled version of the Consumer Assessment of Healthcare Providers and Systems (CAHPS) survey. We calculated scores for overall care as the weighted mean of the case-mix adjusted ratings. Disability caused a greater bias on health plan ratings and specialist ratings than did demographic factors. Proxy respondents rated care the same as self-respondents. Telephone and mail administration were equivalent for service reports, but telephone respondents tended to offer more positive global ratings. Plan-level reliability estimates for new composites on shared decision making and advice on healthy living are .79 and .87, respectively. Plan-level reliability estimates for a new composite measure on family planning did not discriminate between health plans because respondents rated all health plans poorly. Approximately 125 respondents per site are necessary to detect group differences. Self-reported activity limitations incorporating standard questions from the American Community Survey can be used to create a disability case-mix index and to construct profiles of a population's activity limitations. The enabled comparative report, which we call the Assessment of Health Plans and Providers by People with Activity Limitations, is more cognitively accessible than typical CAHPS report templates for state Medicaid plans. The CAHPS Medicaid reporting tools may provide misleading ratings of health plan and physician quality by people with disabilities because the mean ratings do not account for systematic biases associated with disability. More testing on larger populations would help to quantify the strength of various reporting biases.

  11. Validation of a novel robot-assisted 3DUS system for real-time planning and guidance of breast interstitial HDR brachytherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poulin, Eric; Beaulieu, Luc, E-mail: Luc.Beaulieu@phy.ulaval.ca; Gardi, Lori

    Purpose: In current clinical practice, there is no integrated 3D ultrasound (3DUS) guidance system clinically available for breast brachytherapy. In this study, the authors present a novel robot-assisted 3DUS system for real-time planning and guidance of breast interstitial high dose rate (HDR) brachytherapy treatment. Methods: For this work, a new computer controlled robotic 3DUS system was built to perform a hybrid motion scan, which is a combination of a 6 cm linear translation with a 30° rotation at both ends. The new 3DUS scanner was designed to fit on a modified Kuske assembly, keeping the current template grid configuration butmore » modifying the frame to allow the mounting of the 3DUS system at several positions. A finer grid was also tested. A user interface was developed to perform image reconstruction, semiautomatic segmentation of the surgical bed as well as catheter reconstruction and tracking. A 3D string phantom was used to validate the geometric accuracy of the reconstruction. The volumetric accuracy of the system was validated with phantoms using magnetic resonance imaging (MRI) and computed tomography (CT) images. In order to accurately determine whether 3DUS can effectively replace CT for treatment planning, the authors have compared the 3DUS catheter reconstruction to the one obtained from CT images. In addition, in agarose-based phantoms, an end-to-end procedure was performed by executing six independent complete procedures with both 14 and 16 catheters, and for both standard and finer Kuske grids. Finally, in phantoms, five end-to-end procedures were performed with the final CT planning for the validation of 3DUS preplanning. Results: The 3DUS acquisition time is approximately 10 s. A paired Student t-test showed that there was no statistical significant difference between known and measured values of string separations in each direction. Both MRI and CT volume measurements were not statistically different from 3DUS volume (Student t-test: p > 0.05) and they were significantly correlated to 3DUS measurement (Pearson test: MRI p < 0.05 and CT p < 0.001). The mean angular separation distance between catheter trajectories segmented from 3DUS and CT images was 0.42° ± 0.24°, while the maximum and mean trajectory separations were 0.51 ± 0.19 and 0.37 ± 0.17 mm, respectively. Overall, the new finer grid has performed significantly better in terms of dosimetric indices. The planning target volume dosimetric indices were not found statistically different between 3DUS and CT planning (Student t-test, p > 0.05). Both the skin and the pectoral muscle dosimetric indices were within ABS guidelines. Conclusions: A novel robot-assisted 3DUS system was designed and validated. To their knowledge, this is the first system capable of performing real-time guidance and planning of breast multicatheter HDR brachytherapy treatments. Future investigation will test the feasibility of using the system in the clinic and for permanent breast brachytherapy.« less

  12. A blind search for a common signal in gravitational wave detectors

    NASA Astrophysics Data System (ADS)

    Liu, Hao; Creswell, James; von Hausegger, Sebastian; Jackson, Andrew D.; Naselsky, Pavel

    2018-02-01

    We propose a blind, template-free method for the extraction of a common signal between the Hanford and Livingston detectors and apply it especially to the GW150914 event. We construct a log-likelihood method that maximizes the cross-correlation between each detector and the common signal and minimizes the cross-correlation between the residuals. The reliability of this method is tested using simulations with an injected common signal. Finally, our method is used to assess the quality of theoretical gravitational wave templates for GW150914.

  13. [Application of digital design of orthodontic-prosthodontic multidisciplinary treatment plan in esthetic rehabilitation of anterior teeth].

    PubMed

    Liu, Y S; Li, Z; Zhao, Y J; Ye, H Q; Zhou, Y Q; Hu, W J; Liu, Y S; Xun, C L; Zhou, Y S

    2018-02-18

    To develop a digital workflow of orthodontic-prosthodontic multidisciplinary treatment plan which can be applied in complicated anterior teeth esthetic rehabilitation, in order to enhance the efficiency of communication between dentists and patients, and improve the predictability of treatment outcome. Twenty patients with the potential needs of orthodontic-prosthodontic multidisciplinary treatment to solve their complicated esthetic problems in anterior teeth were recruited in this study. Digital models of patients' both dental arches and soft tissues were captured using intra oral scanner. Direct prosthodontic (DP) treatment plan and orthodontic-prosthodontic (OP) treatment plan were carried out for each patient. For DP treatment plans, digital wax-up models were directly designed on original digital models using prosthodontic design system. For OP treatment plans, virtual-setups were performed using orthodontic analyze system according to orthodontic and esthetic criteria and imported to prosthodontic design system to finalize the digital wax-up models. These two treatment plans were shown to the patients and demonstrated elaborately. Each patient rated two treatment plans using visual analogue scales and the medians of scores of two treatment plans were analyzed using signed Wilcoxon test. Having taken into consideration various related factors, including time, costs of treatment, each patient chose a specific treatment plan. For the patients chose DP treatment plans, digital wax-up models were exported and printed into resin diagnostic models which would be utilized in the prosthodontic treatment process. For the patients chose OP treatment plans, virtual-setups were used to fabricate aligners or indirect bonding templates and digital wax-up models were also exported and printed into resin diagnostic models for prosthodontic treatment after orthodontic treatment completed. The medians of scores of DP treatment plan and OP treatment plan were calculated and analyzed by IBM SPSS 20. The median of scores of DP treatment plan was 8.4, the minimum value was 6.9 and the maximum value was 9.3. The median of scores of OP treatment plan was 9.0, the minimum value was 7.9 and the maximum value was 9.6. The median of scores of OP was significantly higher than that of DP (Z=-3.23, P<0.01). Finally, 12 patients chose OP treatment plans and 8 patients chose DP treatment plans. For cases with complex esthetic problems in anterior teeth, a digital workflow can demonstrate final treatment outcome and help patients make suitable treatment decisions. In our study, the orthodontic-prosthodontic multidisciplinary treatment plan is feasible which can provide predictions of treatment outcome and improve esthetic outcome with patients' satisfaction.

  14. Diagnostic Accuracy of Multiparametric Magnetic Resonance Imaging and Fusion Guided Targeted Biopsy Evaluated by Transperineal Template Saturation Prostate Biopsy for the Detection and Characterization of Prostate Cancer.

    PubMed

    Mortezavi, Ashkan; Märzendorfer, Olivia; Donati, Olivio F; Rizzi, Gianluca; Rupp, Niels J; Wettstein, Marian S; Gross, Oliver; Sulser, Tullio; Hermanns, Thomas; Eberli, Daniel

    2018-02-21

    We evaluated the diagnostic accuracy of multiparametric magnetic resonance imaging and multiparametric magnetic resonance imaging/transrectal ultrasound fusion guided targeted biopsy against that of transperineal template saturation prostate biopsy to detect prostate cancer. We retrospectively analyzed the records of 415 men who consecutively presented for prostate biopsy between November 2014 and September 2016 at our tertiary care center. Multiparametric magnetic resonance imaging was performed using a 3 Tesla device without an endorectal coil, followed by transperineal template saturation prostate biopsy with the BiopSee® fusion system. Additional fusion guided targeted biopsy was done in men with a suspicious lesion on multiparametric magnetic resonance imaging, defined as Likert score 3 to 5. Any Gleason pattern 4 or greater was defined as clinically significant prostate cancer. The detection rates of multiparametric magnetic resonance imaging and fusion guided targeted biopsy were compared with the detection rate of transperineal template saturation prostate biopsy using the McNemar test. We obtained a median of 40 (range 30 to 55) and 3 (range 2 to 4) transperineal template saturation prostate biopsy and fusion guided targeted biopsy cores, respectively. Of the 124 patients (29.9%) without a suspicious lesion on multiparametric magnetic resonance imaging 32 (25.8%) were found to have clinically significant prostate cancer on transperineal template saturation prostate biopsy. Of the 291 patients (70.1%) with a Likert score of 3 to 5 clinically significant prostate cancer was detected in 129 (44.3%) by multiparametric magnetic resonance imaging fusion guided targeted biopsy, in 176 (60.5%) by transperineal template saturation prostate biopsy and in 187 (64.3%) by the combined approach. Overall 58 cases (19.9%) of clinically significant prostate cancer would have been missed if fusion guided targeted biopsy had been performed exclusively. The sensitivity of multiparametric magnetic resonance imaging and fusion guided targeted biopsy for clinically significant prostate cancer was 84.6% and 56.7% with a negative likelihood ratio of 0.35 and 0.46, respectively. Multiparametric magnetic resonance imaging alone should not be performed as a triage test due to a substantial number of false-negative cases with clinically significant prostate cancer. Systematic biopsy outperformed fusion guided targeted biopsy. Therefore, it will remain crucial in the diagnostic pathway of prostate cancer. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  15. Adapting Tests of Sign Language Assessment for Other Sign Languages--A Review of Linguistic, Cultural, and Psychometric Problems

    ERIC Educational Resources Information Center

    Haug, Tobias; Mann, Wolfgang

    2008-01-01

    Given the current lack of appropriate assessment tools for measuring deaf children's sign language skills, many test developers have used existing tests of other sign languages as templates to measure the sign language used by deaf people in their country. This article discusses factors that may influence the adaptation of assessment tests from…

  16. Atlas Based Segmentation and Mapping of Organs at Risk from Planning CT for the Development of Voxel-Wise Predictive Models of Toxicity in Prostate Radiotherapy

    NASA Astrophysics Data System (ADS)

    Acosta, Oscar; Dowling, Jason; Cazoulat, Guillaume; Simon, Antoine; Salvado, Olivier; de Crevoisier, Renaud; Haigron, Pascal

    The prediction of toxicity is crucial to managing prostate cancer radiotherapy (RT). This prediction is classically organ wise and based on the dose volume histograms (DVH) computed during the planning step, and using for example the mathematical Lyman Normal Tissue Complication Probability (NTCP) model. However, these models lack spatial accuracy, do not take into account deformations and may be inappropiate to explain toxicity events related with the distribution of the delivered dose. Producing voxel wise statistical models of toxicity might help to explain the risks linked to the dose spatial distribution but is challenging due to the difficulties lying on the mapping of organs and dose in a common template. In this paper we investigate the use of atlas based methods to perform the non-rigid mapping and segmentation of the individuals' organs at risk (OAR) from CT scans. To build a labeled atlas, 19 CT scans were selected from a population of patients treated for prostate cancer by radiotherapy. The prostate and the OAR (Rectum, Bladder, Bones) were then manually delineated by an expert and constituted the training data. After a number of affine and non rigid registration iterations, an average image (template) representing the whole population was obtained. The amount of consensus between labels was used to generate probabilistic maps for each organ. We validated the accuracy of the approach by segmenting the organs using the training data in a leave one out scheme. The agreement between the volumes after deformable registration and the manually segmented organs was on average above 60% for the organs at risk. The proposed methodology provides a way to map the organs from a whole population on a single template and sets the stage to perform further voxel wise analysis. With this method new and accurate predictive models of toxicity will be built.

  17. Functional Connectivity in Multiple Cortical Networks Is Associated with Performance Across Cognitive Domains in Older Adults.

    PubMed

    Shaw, Emily E; Schultz, Aaron P; Sperling, Reisa A; Hedden, Trey

    2015-10-01

    Intrinsic functional connectivity MRI has become a widely used tool for measuring integrity in large-scale cortical networks. This study examined multiple cortical networks using Template-Based Rotation (TBR), a method that applies a priori network and nuisance component templates defined from an independent dataset to test datasets of interest. A priori templates were applied to a test dataset of 276 older adults (ages 65-90) from the Harvard Aging Brain Study to examine the relationship between multiple large-scale cortical networks and cognition. Factor scores derived from neuropsychological tests represented processing speed, executive function, and episodic memory. Resting-state BOLD data were acquired in two 6-min acquisitions on a 3-Tesla scanner and processed with TBR to extract individual-level metrics of network connectivity in multiple cortical networks. All results controlled for data quality metrics, including motion. Connectivity in multiple large-scale cortical networks was positively related to all cognitive domains, with a composite measure of general connectivity positively associated with general cognitive performance. Controlling for the correlations between networks, the frontoparietal control network (FPCN) and executive function demonstrated the only significant association, suggesting specificity in this relationship. Further analyses found that the FPCN mediated the relationships of the other networks with cognition, suggesting that this network may play a central role in understanding individual variation in cognition during aging.

  18. Printed three-dimensional anatomic templates for virtual preoperative planning before reconstruction of old pelvic injuries: initial results.

    PubMed

    Wu, Xin-Bao; Wang, Jun-Qiang; Zhao, Chun-Peng; Sun, Xu; Shi, Yin; Zhang, Zi-An; Li, Yu-Neng; Wang, Man-Yi

    2015-02-20

    Old pelvis fractures are among the most challenging fractures to treat because of their complex anatomy, difficult-to-access surgical sites, and the relatively low incidence of such cases. Proper evaluation and surgical planning are necessary to achieve the pelvic ring symmetry and stable fixation of the fracture. The goal of this study was to assess the use of three-dimensional (3D) printing techniques for surgical management of old pelvic fractures. First, 16 dried human cadaveric pelvises were used to confirm the anatomical accuracy of the 3D models printed based on radiographic data. Next, nine clinical cases between January 2009 and April 2013 were used to evaluate the surgical reconstruction based on the 3D printed models. The pelvic injuries were all type C, and the average time from injury to reconstruction was 11 weeks (range: 8-17 weeks). The workflow consisted of: (1) Printing patient-specific bone models based on preoperative computed tomography (CT) scans, (2) virtual fracture reduction using the printed 3D anatomic template, (3) virtual fracture fixation using Kirschner wires, and (4) preoperatively measuring the osteotomy and implant position relative to landmarks using the virtually defined deformation. These models aided communication between surgical team members during the procedure. This technique was validated by comparing the preoperative planning to the intraoperative procedure. The accuracy of the 3D printed models was within specification. Production of a model from standard CT DICOM data took 7 hours (range: 6-9 hours). Preoperative planning using the 3D printed models was feasible in all cases. Good correlation was found between the preoperative planning and postoperative follow-up X-ray in all nine cases. The patients were followed for 3-29 months (median: 5 months). The fracture healing time was 9-17 weeks (mean: 10 weeks). No delayed incision healing, wound infection, or nonunions occurred. The results were excellent in two cases, good in five, and poor in two based on the Majeed score. The 3D printing planning technique for pelvic surgery was successfully integrated into a clinical workflow to improve patient-specific preoperative planning by providing a visual and haptic model of the injury and allowing patient-specific adaptation of each osteosynthesis implant to the virtually reduced pelvis.

  19. Accuracy of different types of computer-aided design/computer-aided manufacturing surgical guides for dental implant placement

    PubMed Central

    Geng, Wei; Liu, Changying; Su, Yucheng; Li, Jun; Zhou, Yanmin

    2015-01-01

    Purpose: To evaluate the clinical outcomes of implants placed using different types of computer-aided design/computer-aided manufacturing (CAD/CAM) surgical guides, including partially guided and totally guided templates, and determine the accuracy of these guides Materials and methods: In total, 111 implants were placed in 24 patients using CAD/CAM surgical guides. After implant insertion, the positions and angulations of the placed implants relative to those of the planned ones were determined using special software that matched pre- and postoperative computed tomography (CT) images, and deviations were calculated and compared between the different guides and templates. Results: The mean angular deviations were 1.72 ± 1.67 and 2.71 ± 2.58, the mean deviations in position at the neck were 0.27 ± 0.24 and 0.69 ± 0.66 mm, the mean deviations in position at the apex were 0.37 ± 0.35 and 0.94 ± 0.75 mm, and the mean depth deviations were 0.32 ± 0.32 and 0.51 ± 0.48 mm with tooth- and mucosa-supported stereolithographic guides, respectively (P < .05 for all). The mean distance deviations when partially guided (29 implants) and totally guided templates (30 implants) were used were 0.54 ± 0.50 mm and 0.89 ± 0.78 mm, respectively, at the neck and 1.10 ± 0.85 mm and 0.81 ± 0.64 mm, respectively, at the apex, with corresponding mean angular deviations of 2.56 ± 2.23° and 2.90 ± 3.0° (P > .05 for all). Conclusions: Tooth-supported surgical guides may be more accurate than mucosa-supported guides, while both partially and totally guided templates can simplify surgery and aid in optimal implant placement. PMID:26309497

  20. A randomized clinical trial comparing guided implant surgery (bone- or mucosa-supported) with mental navigation or the use of a pilot-drill template.

    PubMed

    Vercruyssen, Marjolein; Cox, Catherine; Coucke, Wim; Naert, Ignace; Jacobs, Reinhilde; Quirynen, Marc

    2014-07-01

    To assess the accuracy of guided surgery (mucosa and bone-supported) compared to mental navigation or the use of a surgical template, in fully edentulous jaws, in a randomized controlled study. Fifty-nine patients (72 jaws), requiring four to six implants (maxilla or mandible), were consecutively recruited and randomly assigned to one of the following treatment groups; guidance via Materialise Universal(®)/mucosa, Materialise Universal(®)/bone, Facilitate™/mucosa, Facilitate™/bone, or mental navigation or a pilot-drill template. The precision was assessed by matching the planning computed tomography (CT) with a post-operative cone beam CT. A significant lower mean deviation at the entry point (1.4 mm, range: 0.3-3.7), at the apex (1.6 mm, range: 0.2-3.7) and angular deviation (3.0°, range: 0.2-16°) was observed for the guiding systems when compared to mental navigation (2.7 mm, range: 0.3-8.3; 2.9 mm, range: 0.5-7.4 and 9.9°, range: 1.5-27.8) and to the surgical template group (3.0 mm, range: 0.6-6.6; 3.4 mm, range: 0.3-7.5 and 8.4°, range: 0.6-21.3°). Differences between bone and mucosa support or type of guidance were negligible. Jaw and implant location (posterior-anterior, left-right), however, had a significant influence on the accuracy when guided. Based on these findings, guided implant placement appears to offer clear accuracy benefits. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Controlling macro- and mesostructures with hierarchical porosity through combined hard and soft templating.

    PubMed

    Petkovich, Nicholas D; Stein, Andreas

    2013-05-07

    Rigid, porous objects and surfactants serve as powerful templates for the formation of mesoporous and macroporous materials. When both types of template are combined in a single synthesis, materials with intricate architectures and hierarchical porosity can be obtained. In this tutorial review, we explain how to conduct syntheses with both soft and hard templates; moreover, we describe methods to control the final structure present in the templated material. Much of the foundation for multiple templating lies in the study of materials made with only one type of template. To establish a foundation in this area, a description of hard and soft templating is given, delving into the templates available and the steps required for effective templating. This leads into an extended discussion about materials templated with both hard and soft templates. Through the use of recent examples in the literature, we aim to show the diversity of structures possible through multiple templating and the advantages these structures can provide for a wide range of applications. An emphasis is placed on how various factors-such as the type of template, type of precursor, heat-treatment temperature, confinement within a small space, and template-template interactions-impact morphology.

  2. 77 FR 52718 - Agency Information Collection Activities: Proposed Information Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-30

    ... nonmember banks and state savings associations titled, ``Annual Stress Test Reporting Template and... FDIC is requesting comment on the following new proposed information collection: Title: Annual Stress... associations, to conduct annual stress tests \\2\\ and requires the primary financial regulatory agency \\3\\ of...

  3. Synthesis of NiO nanotubes for use as negative electrodes in lithium ion batteries

    NASA Astrophysics Data System (ADS)

    Needham, S. A.; Wang, G. X.; Liu, H. K.

    Nickel oxide (NiO) nanotubes have been produced for the first time via a template processing method. The synthesis involved a two step chemical reaction in which nickel hydroxide (Ni(OH) 2) nanotubes were firstly formed within the walls of an anodic aluminium oxide (AAO) template. The template was then dissolved away using concentrated NaOH, and the freed nanotubes were converted to NiO by heat treatment in air at 350 °C. Individual nanotubes measured 60 μm in length with a 200 nm outer diameter and a wall thickness of 20-30 nm. The NiO nanotube powder was used in Li-ion cells for assessment of the lithium storage ability. Preliminary testing indicates that the cells demonstrate controlled and sustainable lithium diffusion after the formation of an SEI. Reversible capacities in the 300 mAh g -1 range were typical.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aguiar, Ana C.; Chao, Kevin; Beroza, Gregory C.

    In this paper, we compare low-frequency earthquakes (LFEs) from triggered and ambient tremor under the southern Central Range, Taiwan. We apply the PageRank algorithm used by Aguiar and Beroza (2014) that exploits the repetitive nature of the LFEs to find repeating LFEs in both ambient and triggered tremor. We use these repeaters to create LFE templates and find that the templates created from both tremor types are very similar. To test their similarity, we use both interchangeably and find that most of both the ambient and triggered tremor match the LFE templates created from either data set, suggesting that LFEsmore » for both events have a common origin. Finally, we locate the LFEs by using local earthquake P wave and S wave information and find that LFEs from triggered and ambient tremor locate to between 20 and 35 km on what we interpret as the deep extension of the Chaochou-Lishan Fault.« less

  5. Development of machine-vision system for gap inspection of muskmelon grafted seedlings.

    PubMed

    Liu, Siyao; Xing, Zuochang; Wang, Zifan; Tian, Subo; Jahun, Falalu Rabiu

    2017-01-01

    Grafting robots have been developed in the world, but some auxiliary works such as gap-inspecting for grafted seedlings still need to be done by human. An machine-vision system of gap inspection for grafted muskmelon seedlings was developed in this study. The image acquiring system consists of a CCD camera, a lens and a front white lighting source. The image of inspected gap was processed and analyzed by software of HALCON 12.0. The recognition algorithm for the system is based on principle of deformable template matching. A template should be created from an image of qualified grafted seedling gap. Then the gap image of the grafted seedling will be compared with the created template to determine their matching degree. Based on the similarity between the gap image of grafted seedling and the template, the matching degree will be 0 to 1. The less similar for the grafted seedling gap with the template the smaller of matching degree. Thirdly, the gap will be output as qualified or unqualified. If the matching degree of grafted seedling gap and the template is less than 0.58, or there is no match is found, the gap will be judged as unqualified; otherwise the gap will be qualified. Finally, 100 muskmelon seedlings were grafted and inspected to test the gap inspection system. Results showed that the gap inspection machine-vision system could recognize the gap qualification correctly as 98% of human vision. And the inspection speed of this system can reach 15 seedlings·min-1. The gap inspection process in grafting can be fully automated with this developed machine-vision system, and the gap inspection system will be a key step of a fully-automatic grafting robots.

  6. Automatic delineation of brain regions on MRI and PET images from the pig.

    PubMed

    Villadsen, Jonas; Hansen, Hanne D; Jørgensen, Louise M; Keller, Sune H; Andersen, Flemming L; Petersen, Ida N; Knudsen, Gitte M; Svarer, Claus

    2018-01-15

    The increasing use of the pig as a research model in neuroimaging requires standardized processing tools. For example, extraction of regional dynamic time series from brain PET images requires parcellation procedures that benefit from being automated. Manual inter-modality spatial normalization to a MRI atlas is operator-dependent, time-consuming, and can be inaccurate with lack of cortical radiotracer binding or skull uptake. A parcellated PET template that allows for automatic spatial normalization to PET images of any radiotracer. MRI and [ 11 C]Cimbi-36 PET scans obtained in sixteen pigs made the basis for the atlas. The high resolution MRI scans allowed for creation of an accurately averaged MRI template. By aligning the within-subject PET scans to their MRI counterparts, an averaged PET template was created in the same space. We developed an automatic procedure for spatial normalization of the averaged PET template to new PET images and hereby facilitated transfer of the atlas regional parcellation. Evaluation of the automatic spatial normalization procedure found the median voxel displacement to be 0.22±0.08mm using the MRI template with individual MRI images and 0.92±0.26mm using the PET template with individual [ 11 C]Cimbi-36 PET images. We tested the automatic procedure by assessing eleven PET radiotracers with different kinetics and spatial distributions by using perfusion-weighted images of early PET time frames. We here present an automatic procedure for accurate and reproducible spatial normalization and parcellation of pig PET images of any radiotracer with reasonable blood-brain barrier penetration. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. DNA-Templated Polymerization of Side-Chain-Functionalized Peptide Nucleic Acid Aldehydes

    PubMed Central

    Kleiner, Ralph E.; Brudno, Yevgeny; Birnbaum, Michael E.; Liu, David R.

    2009-01-01

    The DNA-templated polymerization of synthetic building blocks provides a potential route to the laboratory evolution of sequence-defined polymers with structures and properties not necessarily limited to those of natural biopolymers. We previously reported the efficient and sequence-specific DNA-templated polymerization of peptide nucleic acid (PNA) aldehydes. Here, we report the enzyme-free, DNA-templated polymerization of side-chain-functionalized PNA tetramer and pentamer aldehydes. We observed that the polymerization of tetramer and pentamer PNA building blocks with a single lysine-based side chain at various positions in the building block could proceed efficiently and sequence-specifically. In addition, DNA-templated polymerization also proceeded efficiently and in a sequence-specific manner with pentamer PNA aldehydes containing two or three lysine side chains in a single building block to generate more densely functionalized polymers. To further our understanding of side-chain compatibility and expand the capabilities of this system, we also examined the polymerization efficiencies of 20 pentamer building blocks each containing one of five different side-chain groups and four different side-chain regio- and stereochemistries. Polymerization reactions were efficient for all five different side-chain groups and for three of the four combinations of side-chain regio- and stereochemistries. Differences in the efficiency and initial rate of polymerization correlate with the apparent melting temperature of each building block, which is dependent on side-chain regio- and stereochemistry, but relatively insensitive to side-chain structure among the substrates tested. Our findings represent a significant step towards the evolution of sequence-defined synthetic polymers and also demonstrate that enzyme-free nucleic acid-templated polymerization can occur efficiently using substrates with a wide range of side-chain structures, functionalization positions within each building block, and functionalization densities. PMID:18341334

  8. Development and implementation of a quality assurance program for a hormonal contraceptive implant.

    PubMed

    Owen, Derek H; Jenkins, David; Cancel, Aida; Carter, Eli; Dorflinger, Laneta; Spieler, Jeff; Steiner, Markus J

    2013-04-01

    The importance of the distribution of safe, effective and cost-effective pharmaceutical products in resource-constrained countries is the subject of increasing attention. FHI 360 has developed a program aimed at evaluating the quality of a contraceptive implant manufactured in China, while the product is being registered in an increasing number of countries and distributed by international procurement agencies. The program consists of (1) independent product testing; (2) ongoing evaluation of the manufacturing facility through audits and inspections; and (3) post-marketing surveillance. This article focuses on the laboratory testing of the product. The various test methods were chosen from the following test method compendia, the United States Pharmacopeia (USP), British Pharmacopeia (BP), International Organization for Standardization (ISO), the American Society for Testing and Materials (ASTM), or lot release tests mandated by Chinese regulatory requirements. Each manufactured lot is independently tested prior to its distribution to countries supported by this program. In addition, a more detailed annual testing program includes evaluation of the active ingredient (levonorgestrel), the final product and the packaging material. Over the first 4 years of this 5-year project, all tested lots met the established quality criteria. The quality assurance program developed for this contraceptive implant has helped ensure that a safe product was being introduced into developing country family planning programs. This program provides a template for establishing quality assurance programs for other cost-effective pharmaceutical products that have not yet received stringent regulatory approval and are being distributed in resource-poor settings. Copyright © 2013 Elsevier Inc. All rights reserved.

  9. [Algorithm of locally adaptive region growing based on multi-template matching applied to automated detection of hemorrhages].

    PubMed

    Gao, Wei-Wei; Shen, Jian-Xin; Wang, Yu-Liang; Liang, Chun; Zuo, Jing

    2013-02-01

    In order to automatically detect hemorrhages in fundus images, and develop an automated diabetic retinopathy screening system, a novel algorithm named locally adaptive region growing based on multi-template matching was established and studied. Firstly, spectral signature of major anatomical structures in fundus was studied, so that the right channel among RGB channels could be selected for different segmentation objects. Secondly, the fundus image was preprocessed by means of HSV brightness correction and contrast limited adaptive histogram equalization (CLAHE). Then, seeds of region growing were founded out by removing optic disc and vessel from the resulting image of normalized cross-correlation (NCC) template matching on the previous preprocessed image with several templates. Finally, locally adaptive region growing segmentation was used to find out the exact contours of hemorrhages, and the automated detection of the lesions was accomplished. The approach was tested on 90 different resolution fundus images with variable color, brightness and quality. Results suggest that the approach could fast and effectively detect hemorrhages in fundus images, and it is stable and robust. As a result, the approach can meet the clinical demands.

  10. Construction of population-specific Indian MRI brain template: Morphometric comparison with Chinese and Caucasian templates.

    PubMed

    Bhalerao, Gaurav Vivek; Parlikar, Rujuta; Agrawal, Rimjhim; Shivakumar, Venkataram; Kalmady, Sunil V; Rao, Naren P; Agarwal, Sri Mahavir; Narayanaswamy, Janardhanan C; Reddy, Y C Janardhan; Venkatasubramanian, Ganesan

    2018-06-01

    Spatial normalization of brain MR images is highly dependent on the choice of target brain template. Morphological differences caused by factors like genetic and environmental exposures, generates a necessity to construct population specific brain templates. Brain image analysis performed using brain templates from Caucasian population may not be appropriate for non-Caucasian population. In this study, our objective was to construct an Indian brain template from a large population (N = 157 subjects) and compare the morphometric parameters of this template with that of Chinese-56 and MNI-152 templates. In addition, using an independent MRI data of 15 Indian subjects, we also evaluated the potential registration accuracy differences using these three templates. Indian brain template was constructed using iterative routines as per established procedures. We compared our Indian template with standard MNI-152 template and Chinese template by measuring global brain features. We also examined accuracy of registration by aligning 15 new Indian brains to Indian, Chinese and MNI templates. Furthermore, we supported our measurement protocol with inter-rater and intra-rater reliability analysis. Our results showed that there were significant differences in global brain features of Indian template in comparison with Chinese and MNI brain templates. The results of registration accuracy analysis revealed that fewer deformations are required when Indian brains are registered to Indian template as compared to Chinese and MNI templates. This study concludes that population specific Indian template is likely to be more appropriate for structural and functional image analysis of Indian population. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. SU-F-T-47: MRI T2 Exclusive Based Planning Using the Endocavitary/interstitial Gynecological Benidorm Applicator: A Proposed TPS Library and Preplan Efficient Methodology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richart, J; Otal, A; Rodriguez, S

    Purpose: ABS and GEC-ESTRO have recommended MRI T2 for image guided brachytherapy. Recently, a new applicator (Benidorm Template, TB) has been developed in our Department (Rodriguez et al 2015). TB is fully MRI compatible because the Titanium needles and it allows the use of intrauterine tandem. Currently, TPS applicators library are not currently available for non-rigid applicators in case of interstitial component as the TB.The purpose of this work is to present the development of a library for the TB, together with its use on a pre-planning technique. Both new goals allow a very efficient and exclusive T2 MRI basedmore » planning clinical TB implementation. Methods: The developed library has been implemented in Oncentra Brachytherapy TPS, version 4.3.0 (Elekta) and now is being implemented on Sagiplan v 2.0 TPS (Eckert&Ziegler BEBIG). To model the TB, free and open software named FreeCAD and MeshLab have been used. The reconstruction process is based on three inserted A-vitamin pellets together with the data provided by the free length. The implemented preplanning procedure is as follow: 1) A MRI T2 acquisition is performed with the template in place just with the vaginal cylinder (no uterine tube nor needles). 2) The CTV is drawn and the required needles are selected using a developed Java based application and 3) A post-implant MRI T2 is performed. Results: This library procedure has been successfully applied by now in 25 patients. In this work the use of the developed library will be illustrated with clinical examples. The preplanning procedure has been applied by now in 6 patients, having significant advantages: needle depth estimation, needle positions and number are optimized a priori, time saving, etc Conclusion: TB library and pre-plan techniques are feasible and very efficient and their use will be illustrated in this work.« less

  12. Activity Scratchpad Prototype: Simplifying the Rover Activity Planning Cycle

    NASA Technical Reports Server (NTRS)

    Abramyan, Lucy

    2005-01-01

    The Mars Exploration Rover mission depends on the Science Activity Planner as its primary interface to the Spirit and Opportunity Rovers. Scientists alternate between a series of mouse clicks and keyboard inputs to create a set of instructions for the rovers. To accelerate planning by minimizing mouse usage, a rover planning editor should receive the majority of inputted commands from the keyboard. Thorough investigation of the Eclipse platform's Java editor has provided the understanding of the base model for the Activity Scratchpad. Desirable Eclipse features can be mapped to specific rover planning commands, such as auto-completion for activity titles and content assist for target names. A custom editor imitating the Java editor's features was created with an XML parser for experimenting purposes. The prototype editor minimized effort for redundant tasks and significantly improved the visual representation of XML syntax by highlighting keywords, coloring rules, folding projections, and providing hover assist, templates and an outline view of the code.

  13. Study of dosimetric variation due to interfraction organ movement in High Dose Rate Interstital (MUPIT) brachytherapy for gynecologic malignancies

    NASA Astrophysics Data System (ADS)

    Velmurugan, Thanigaimalai; Sukumar, Prabakar; Krishnappan, Chokkalingam; Boopathy, Raghavendiran

    2010-01-01

    Ten patients with cancer of uterine cervix who underwent interstitial brachytherapy using MUPIT templates were CT scanned (CT1) using which bladder, rectum and CTV were delineated. The treatment plan PCT1 was generated and optimized geometrically on the volume. CT scan (CT2) was repeated before the second fraction of the treatment CTV and critical organs were delineated. The plan (PCT2) was created by reproducing the Plan PCT1 in the CT2 images and compared with PCT1. Bladder, Rectum and CTV percentage volume variation ranges from +28.6% to -34.3%, 38.4% to -14.9% and 8.5% to -15.2% respectively. Maximum dose variation in bladder was +17.1%, in rectum was up to +410% and in CTV was -13.0%. The dose to these structures varies independently with no strong correlation with the volume variation. Hence it is suggested that repeat CT and re-planning is mandatory before second fraction execution.

  14. EnergyPlus Graphical User Interface

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2011-01-04

    LBNL, Infosys Technologies and Digital Alchemy are developing a free, comprehensive graphical user interface (GUI) that will enable EnergyPlus to be used more easily and effectively by building designers and other professionals, facilitating its widespread adoption. User requirements have been defined through a series of practitioner workshops. A new schematic editor for HVAC systems will be combined with different building envelope geometry generation tools and IFC-based BIM import and export. LBNL and Digital Alchemy have generated a detailed function requirements specification, which is being implemented in software by Infosys, LBNL and and Digital Alchemy. LBNL and practitioner subcontractors will developmore » a comprehensive set of templates and libraries and will perform extensive testing of the GUI before it is released in Q3 2011. It is planned to use an Open Platfom approach, in which a comprehensive set of well documented Application Programming Interfaces (API's) would be provided to facilitate both the development of third party contributions to the official, standard GUI and the development of derivative works.« less

  15. Development of Uniform Protocol for Alopecia Areata Clinical Trials.

    PubMed

    Solomon, James A

    2015-11-01

    Developing a successful treatment for alopecia areata (AA), clearly has not been at the forefront of the agenda for new drug/device development among the pharmaceutical and medical device industry. The National Alopecia Areata Foundation (NAAF), a patient advocacy group, initiated a plan to facilitate and drive clinical research toward finding safe and efficacious treatments for AA. As such, Alopecia Areata Uniform Protocols for clinical trials to test new treatments for AA were developed. The design of the uniform protocol is to accomplish the development of a plug-and-play template as well as to provide a framework wherein data from studies utilizing the uniform protocol can be compared through consistency of inclusions/exclusions, safety, and outcome assessment measures. A core uniform protocol for use by pharmaceutical companies in testing proof of concept for investigational products to treat AA. The core protocol includes standardized title, informed consent, inclusion/exclusion criteria, disease outcome assessments, and safety assessments. The statistical methodology to assess successful outcomes will also be standardized. The protocol as well as the informed consent form has been approved in concept by Liberty IRB and is ready to present to pharmaceutical companies.

  16. Three Dimensional Object Recognition Using a Complex Autoregressive Model

    DTIC Science & Technology

    1993-12-01

    3.4.2 Template Matching Algorithm ...................... 3-16 3.4.3 K-Nearest-Neighbor ( KNN ) Techniques ................. 3-25 3.4.4 Hidden Markov Model...Neighbor ( KNN ) Test Results ...................... 4-13 4.2.1 Single-Look 1-NN Testing .......................... 4-14 4.2.2 Multiple-Look 1-NN Testing...4-15 4.2.3 Discussion of KNN Test Results ...................... 4-15 4.3 Hidden Markov Model (HMM) Test Results

  17. Problem-Solving Test: Real-Time Polymerase Chain Reaction

    ERIC Educational Resources Information Center

    Szeberenyi, Jozsef

    2009-01-01

    Terms to be familiar with before you start to solve the test: polymerase chain reaction, DNA amplification, electrophoresis, breast cancer, "HER2" gene, genomic DNA, "in vitro" DNA synthesis, template, primer, Taq polymerase, 5[prime][right arrow]3[prime] elongation activity, 5[prime][right arrow]3[prime] exonuclease activity, deoxyribonucleoside…

  18. Problem-Solving Test: Expression Cloning of the Erythropoietin Receptor

    ERIC Educational Resources Information Center

    Szeberenyi, Jozsef

    2008-01-01

    Terms to be familiar with before you start to solve the test: cytokines, cytokine receptors, cDNA library, cDNA synthesis, poly(A)[superscript +] RNA, primer, template, reverse transcriptase, restriction endonucleases, cohesive ends, expression vector, promoter, Shine-Dalgarno sequence, poly(A) signal, DNA helicase, DNA ligase, topoisomerases,…

  19. Crisis checklists for in-hospital emergencies: expert consensus, simulation testing and recommendations for a template determined by a multi-institutional and multi-disciplinary learning collaborative.

    PubMed

    Subbe, Christian P; Kellett, John; Barach, Paul; Chaloner, Catriona; Cleaver, Hayley; Cooksley, Tim; Korsten, Erik; Croke, Eilish; Davis, Elinor; De Bie, Ashley Jr; Durham, Lesley; Hancock, Chris; Hartin, Jilian; Savijn, Tracy; Welch, John

    2017-05-08

    'Failure to rescue' of hospitalized patients with deteriorating physiology on general wards is caused by a complex array of organisational, technical and cultural failures including a lack of standardized team and individual expected responses and actions. The aim of this study using a learning collaborative method was to develop consensus recomendations on the utility and effectiveness of checklists as training and operational tools to assist in improving the skills of general ward staff on the effective rescue of patients with abnormal physiology. A scoping study of the literature was followed by a multi-institutional and multi-disciplinary international learning collaborative. We sought to achieve a consensus on procedures and clinical simulation technology to determine the requirements, develop and test a safe using a checklist template that is rapidly accessible to assist in emergency management of common events for general ward use. Safety considerations about deteriorating patients were agreed upon and summarized. A consensus was achieved among an international group of experts on currently available checklist formats performing poorly in simulation testing as first responders in general ward clinical crises. The Crisis Checklist Collaborative ratified a consensus template for a general ward checklist that provides a list of issues for first responders to address (i.e. 'Check In'), a list of prompts regarding common omissions (i.e. 'Stop & Think'), and, a list of items required for the safe "handover" of patients that remain on the general ward (i.e. 'Check Out'). Simulation usability assessment of the template demonstrated feasibility for clinical management of deteriorating patients. Emergency checklists custom-designed for general ward patients have the potential to guide the treatment speed and reliability of responses for emergency management of patients with abnormal physiology while minimizing the risk of adverse events. Interventional trials are needed.

  20. Poster - 09: A MATLAB-based Program for Automated Quality Assurance of a Prostate Brachytherapy Ultrasound System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poon, Justin; Sabondjian, Eric; Sankreacha, Raxa

    Purpose: A robust Quality Assurance (QA) program is essential for prostate brachytherapy ultrasound systems due to the importance of imaging accuracy during treatment and planning. Task Group 128 of the American Association of Physicists in Medicine has recommended a set of QA tests covering grayscale visibility, depth of penetration, axial and lateral resolution, distance measurement, area measurement, volume measurement, and template/electronic grid alignment. Making manual measurements on the ultrasound system can be slow and inaccurate, so a MATLAB program was developed for automation of the described tests. Methods: Test images were acquired using a BK Medical Flex Focus 400 ultrasoundmore » scanner and 8848 transducer with the CIRS Brachytherapy QA Phantom – Model 045A. For each test, the program automatically segments the inputted image(s), makes the appropriate measurements, and indicates if the test passed or failed. The program was tested by analyzing two sets of images, where the measurements from the first set were used as baseline values. Results: The program successfully analyzed the images for each test and determined if any action limits were exceeded. All tests passed – the measurements made by the program were consistent and met the requirements outlined by Task Group 128. Conclusions: The MATLAB program we have developed can be used for automated QA of an ultrasound system for prostate brachytherapy. The GUI provides a user-friendly way to analyze images without the need for any manual measurement, potentially removing intra- and inter-user variability for more consistent results.« less

  1. MRP (materiel requirements planning) II implementation: a case study.

    PubMed

    Sheldon, D

    1994-05-01

    Manufacturing resource planning (MRP II) is a powerful and effective business planning template on which to build a continuous improvement culture. MRP II, when successfully implemented, encourages a disciplined yet nonthreatening environment centered on measurement and accountability. From the education that accompanies an MRP II implementation, the employees can better understand the vision and mission of the organization. This common goal keeps everyone's energy directed toward the same final objective. The Raymond Corporation is a major materiels handling equipment manufacturer headquartered in Greene, New York, with class "A" MRP II manufacturing facilities in Greene and Brantford, Ontario and an aftermark distribution facility in East Syracuse, New York. Prior to the implementation of MRP II in its Greene plant (from 1988 through 1990) good intentions and hard work were proving to be less than necessary to compete in the global market. Certified class "A" in February 1990. The Raymond Corporation has built a world-class organization from these foundations.

  2. Conversion of Radiology Reporting Templates to the MRRT Standard.

    PubMed

    Kahn, Charles E; Genereaux, Brad; Langlotz, Curtis P

    2015-10-01

    In 2013, the Integrating the Healthcare Enterprise (IHE) Radiology workgroup developed the Management of Radiology Report Templates (MRRT) profile, which defines both the format of radiology reporting templates using an extension of Hypertext Markup Language version 5 (HTML5), and the transportation mechanism to query, retrieve, and store these templates. Of 200 English-language report templates published by the Radiological Society of North America (RSNA), initially encoded as text and in an XML schema language, 168 have been converted successfully into MRRT using a combination of automated processes and manual editing; conversion of the remaining 32 templates is in progress. The automated conversion process applied Extensible Stylesheet Language Transformation (XSLT) scripts, an XML parsing engine, and a Java servlet. The templates were validated for proper HTML5 and MRRT syntax using web-based services. The MRRT templates allow radiologists to share best-practice templates across organizations and have been uploaded to the template library to supersede the prior XML-format templates. By using MRRT transactions and MRRT-format templates, radiologists will be able to directly import and apply templates from the RSNA Report Template Library in their own MRRT-compatible vendor systems. The availability of MRRT-format reporting templates will stimulate adoption of the MRRT standard and is expected to advance the sharing and use of templates to improve the quality of radiology reports.

  3. Applying automatic item generation to create cohesive physics testlets

    NASA Astrophysics Data System (ADS)

    Mindyarto, B. N.; Nugroho, S. E.; Linuwih, S.

    2018-03-01

    Computer-based testing has created the demand for large numbers of items. This paper discusses the production of cohesive physics testlets using an automatic item generation concepts and procedures. The testlets were composed by restructuring physics problems to reveal deeper understanding of the underlying physical concepts by inserting a qualitative question and its scientific reasoning question. A template-based testlet generator was used to generate the testlet variants. Using this methodology, 1248 testlet variants were effectively generated from 25 testlet templates. Some issues related to the effective application of the generated physics testlets in practical assessments were discussed.

  4. Improved Low Temperature Performance of Supercapacitors

    NASA Technical Reports Server (NTRS)

    Brandon, Erik J.; West, William C.; Smart, Marshall C.; Gnanaraj, Joe

    2013-01-01

    Low temperature double-layer capacitor operation enabled by: - Base acetonitrile / TEATFB salt formulation - Addition of low melting point formates, esters and cyclic ethers center dot Key electrolyte design factors: - Volume of co-solvent - Concentration of salt center dot Capacity increased through higher capacity electrodes: - Zeolite templated carbons - Asymmetric cell designs center dot Continuing efforts - Improve asymmetric cell performance at low temperature - Cycle life testing Motivation center dot Benchmark performance of commercial cells center dot Approaches for designing low temperature systems - Symmetric cells (activated carbon electrodes) - Symmetric cells (zeolite templated carbon electrodes) - Asymmetric cells (lithium titanate/activated carbon electrodes) center dot Experimental results center dot Summary

  5. Cloning nanocrystal morphology with soft templates

    NASA Astrophysics Data System (ADS)

    Thapa, Dev Kumar; Pandey, Anshu

    2016-08-01

    In most template directed preparative methods, while the template decides the nanostructure morphology, the structure of the template itself is a non-general outcome of its peculiar chemistry. Here we demonstrate a template mediated synthesis that overcomes this deficiency. This synthesis involves overgrowth of silica template onto a sacrificial nanocrystal. Such templates are used to copy the morphologies of gold nanorods. After template overgrowth, gold is removed and silver is regrown in the template cavity to produce a single crystal silver nanorod. This technique allows for duplicating existing nanocrystals, while also providing a quantifiable breakdown of the structure - shape interdependence.

  6. The skeptic's guide to a movement for universal health insurance.

    PubMed

    Nathanson, Constance A

    2003-01-01

    The social movement has become institutionalized as a form of political action. The aim of this article is to evaluate the possibilities presented by this form as a strategy to bring about universal health insurance in the United States. I draw on the work of social movement theorists, on the substantial body of empirical research on health-related social movements, and on relevant comparative work from Canada to develop a template for this evaluation. Using that template I compare the failed campaign for President Bill Clinton's health insurance plan with a recent, more successful campaign in the state of New York. I conclude that the keys to success are, first, a broad-based coalition that combines an ideologically and/or grievance-motivated grass roots with financially and politically well-endowed mainstream organizations; second, a "master frame" that resonates with the American people; and, third, a political window of opportunity. The prospects for such a conjunction are not hopeless, but they are not high.

  7. An automatic multi-atlas prostate segmentation in MRI using a multiscale representation and a label fusion strategy

    NASA Astrophysics Data System (ADS)

    Álvarez, Charlens; Martínez, Fabio; Romero, Eduardo

    2015-01-01

    The pelvic magnetic Resonance images (MRI) are used in Prostate cancer radiotherapy (RT), a process which is part of the radiation planning. Modern protocols require a manual delineation, a tedious and variable activity that may take about 20 minutes per patient, even for trained experts. That considerable time is an important work ow burden in most radiological services. Automatic or semi-automatic methods might improve the efficiency by decreasing the measure times while conserving the required accuracy. This work presents a fully automatic atlas- based segmentation strategy that selects the more similar templates for a new MRI using a robust multi-scale SURF analysis. Then a new segmentation is achieved by a linear combination of the selected templates, which are previously non-rigidly registered towards the new image. The proposed method shows reliable segmentations, obtaining an average DICE Coefficient of 79%, when comparing with the expert manual segmentation, under a leave-one-out scheme with the training database.

  8. Problem-Solving Test: RNA and Protein Synthesis in Bacteriophage-Infected "E. coli" Cells

    ERIC Educational Resources Information Center

    Szeberenyi, Jozsef

    2008-01-01

    The classic experiment presented in this problem-solving test was designed to identify the template molecules of translation by analyzing the synthesis of phage proteins in "Escherichia coli" cells infected with bacteriophage T4. The work described in this test led to one of the most seminal discoveries of early molecular biology: it dealt a…

  9. An Overview of NASA's IM&S Verification and Validation Process Plan and Specification for Space Exploration

    NASA Technical Reports Server (NTRS)

    Gravitz, Robert M.; Hale, Joseph

    2006-01-01

    NASA's Exploration Systems Mission Directorate (ESMD) is implementing a management approach for modeling and simulation (M&S) that will provide decision-makers information on the model's fidelity, credibility, and quality. This information will allow the decision-maker to understand the risks involved in using a model's results in the decision-making process. This presentation will discuss NASA's approach for verification and validation (V&V) of its models or simulations supporting space exploration. This presentation will describe NASA's V&V process and the associated M&S verification and validation (V&V) activities required to support the decision-making process. The M&S V&V Plan and V&V Report templates for ESMD will also be illustrated.

  10. Preparing for imported Ebola cases in Israel, 2014 to 2015.

    PubMed

    Brosh-Nissimov, Tal; Poles, Lion; Kassirer, Micha; Singer, Roee; Kaliner, Ehud; Shriki, Dikla Dahan; Anis, Emilia; Fogel, Itay; Engelhard, Dan; Grotto, Itamar

    2015-01-01

    During the current outbreak of Ebola virus disease (EVD) in West Africa, preventing exportation of the disease posed many challenges for economically more developed countries. In Israel, although the risk of importing single cases was assumed to be low, the implications of local transmission were great. This article describes the EVD preparedness plan of the Israeli Ministry of Health. Key elements were a sensitive case definition, designation of a single treatment centre for suspected and confirmed cases, construction of a mobile unit using customised negative-pressure tents and a vigorous national training programme. There were no patients with EVD in Israel, but a few suspected cases were assessed. The Israeli plan may provide a template for emergency infectious disease response in other geographically small countries.

  11. Fast template matching with polynomials.

    PubMed

    Omachi, Shinichiro; Omachi, Masako

    2007-08-01

    Template matching is widely used for many applications in image and signal processing. This paper proposes a novel template matching algorithm, called algebraic template matching. Given a template and an input image, algebraic template matching efficiently calculates similarities between the template and the partial images of the input image, for various widths and heights. The partial image most similar to the template image is detected from the input image for any location, width, and height. In the proposed algorithm, a polynomial that approximates the template image is used to match the input image instead of the template image. The proposed algorithm is effective especially when the width and height of the template image differ from the partial image to be matched. An algorithm using the Legendre polynomial is proposed for efficient approximation of the template image. This algorithm not only reduces computational costs, but also improves the quality of the approximated image. It is shown theoretically and experimentally that the computational cost of the proposed algorithm is much smaller than the existing methods.

  12. The construction of MRI brain/head templates for Chinese children from 7 to 16 years of age

    PubMed Central

    Xie, Wanze; Richards, John E.; Lei, Du; Zhu, Hongyan; Lee, Kang; Gong, Qiyong

    2015-01-01

    Population-specific brain templates that provide detailed brain information are beneficial to both structural and functional neuroimaging research. However, age-specific MRI templates have not been constructed for Chinese or any Asian developmental populations. This study developed novel T1-weighted average brain and head templates for Chinese children from 7 to 16 years of age in two-year increments using high quality magnetic resonance imaging (MRI) and well-validated image analysis techniques. A total of 138 Chinese children (51 F/87 M) were included in this study. The internally and externally validated registrations show that these Chinese age-specific templates fit Chinese children’s MR images significantly better than age-specific templates created from U.S. children, or adult templates based on either Chinese or North American adults. It implies that age-inappropriate (e.g., the Chinese56 template, the US20–24 template) and nationality-inappropriate brain templates (e.g., U.S. children’s templates, the US20–24 template) do not provide optimal reference MRIs for processing MR brain images of Chinese pediatric populations. Thus, our age-specific MRI templates are the first of the kind and should be useful in neuroimaging studies with children from Chinese or other Asian populations. These templates can also serve as the foundations for the construction of more comprehensive sets of nationality-specific templates for Asian developmental populations. These templates are available for use in our database. PMID:26343862

  13. The Meselson-Stahl Experiment

    ERIC Educational Resources Information Center

    Szeberenyi, Jozsef

    2012-01-01

    Terms to be familiar with before you start to solve the test: DNA replication, nitrogen isotopes, density labeling, cesium chloride density gradient centrifugation, ultraviolet absorption, DNA denaturation, circular and linear DNA, superspiralization, superhelical DNA, and template.

  14. Model development, testing and experimentation in a CyberWorkstation for Brain-Machine Interface research.

    PubMed

    Rattanatamrong, Prapaporn; Matsunaga, Andrea; Raiturkar, Pooja; Mesa, Diego; Zhao, Ming; Mahmoudi, Babak; Digiovanna, Jack; Principe, Jose; Figueiredo, Renato; Sanchez, Justin; Fortes, Jose

    2010-01-01

    The CyberWorkstation (CW) is an advanced cyber-infrastructure for Brain-Machine Interface (BMI) research. It allows the development, configuration and execution of BMI computational models using high-performance computing resources. The CW's concept is implemented using a software structure in which an "experiment engine" is used to coordinate all software modules needed to capture, communicate and process brain signals and motor-control commands. A generic BMI-model template, which specifies a common interface to the CW's experiment engine, and a common communication protocol enable easy addition, removal or replacement of models without disrupting system operation. This paper reviews the essential components of the CW and shows how templates can facilitate the processes of BMI model development, testing and incorporation into the CW. It also discusses the ongoing work towards making this process infrastructure independent.

  15. Enhancement of increments in spectral amplitude: further evidence for a mechanism based on central adaptation.

    PubMed

    Carcagno, Samuele; Semal, Catherine; Demany, Laurent

    2013-01-01

    The threshold for detecting a tone in a multitone masker is lower when the masker-plus-signal stimulus is preceded by a copy of the masker. One potential explanation of this "enhancement" phenomenon is that the -precursor stimulus acts as a "template" of the subsequent masker, thus helping listeners to segregate the signal from the masker. To assess this idea, we measured enhancement for precursors that were perceptually similar to the masker and for precursors that were made dissimilar to the masker by gating their components asynchronously. We found that the two types of precursor produced similar amounts of enhancement. This was true not only when the precursor and the subsequent test stimulus were presented to the same ear but also when they were presented to opposite ears. In a second experiment, we checked that the precursors with asynchronously gated components were perceptually poor templates of the subsequent maskers. Listeners now had to discriminate between test stimuli -containing the same components as the precursor and test stimuli containing all but one of the precursor components. We found that in this experimental situation, where enhancement could play no role, gating the precursor components asynchronously disrupted performance. Overall, our results are inconsistent with the hypothesis that precursors producing enhancement are beneficial because they are used as perceptual templates of the masker. Our results are instead consistent with an -explanation of enhancement based on selective neural adaptation taking place at a central locus of the auditory system.

  16. Biometric template transformation: a security analysis

    NASA Astrophysics Data System (ADS)

    Nagar, Abhishek; Nandakumar, Karthik; Jain, Anil K.

    2010-01-01

    One of the critical steps in designing a secure biometric system is protecting the templates of the users that are stored either in a central database or on smart cards. If a biometric template is compromised, it leads to serious security and privacy threats because unlike passwords, it is not possible for a legitimate user to revoke his biometric identifiers and switch to another set of uncompromised identifiers. One methodology for biometric template protection is the template transformation approach, where the template, consisting of the features extracted from the biometric trait, is transformed using parameters derived from a user specific password or key. Only the transformed template is stored and matching is performed directly in the transformed domain. In this paper, we formally investigate the security strength of template transformation techniques and define six metrics that facilitate a holistic security evaluation. Furthermore, we analyze the security of two wellknown template transformation techniques, namely, Biohashing and cancelable fingerprint templates based on the proposed metrics. Our analysis indicates that both these schemes are vulnerable to intrusion and linkage attacks because it is relatively easy to obtain either a close approximation of the original template (Biohashing) or a pre-image of the transformed template (cancelable fingerprints). We argue that the security strength of template transformation techniques must consider also consider the computational complexity of obtaining a complete pre-image of the transformed template in addition to the complexity of recovering the original biometric template.

  17. The Effect of Radiation on Selected Photographic Film

    NASA Technical Reports Server (NTRS)

    Slater, Richard; Kinard, John; Firsov, Ivan

    2000-01-01

    We conducted this film test to evaluate several manufacturers' photographic films for their ability to acquire imagery on the International Space Station. We selected 25 motion picture, photographic slide, and negative films from three different film manufacturers. We based this selection on the fact that their films ranked highest in other similar film tests, and on their general acceptance by the international community. This test differed from previous tests because the entire evaluation process leading up to the final selection was based on information derived after the original flight film was scanned to a digital file. Previously conducted tests were evaluated entirely based on 8 x 10s that were produced from the film either directly or through the internegative process. This new evaluation procedure provided accurate quantitative data on granularity and contrast from the digital data. This test did not try to define which film was best visually. This is too often based on personal preference. However, the test results did group the films by good, marginal, and unacceptable. We developed, and included in this report, a template containing quantitative, graphical, and visual information for each film. These templates should be sufficient for comparing the different films tested and subsequently selecting a film or films to be used for experiments and general documentation on the International Space Station.

  18. The Role of Standardized and Study-specific Human Brain Diffusion Tensor Templates in Inter-subject Spatial Normalization

    PubMed Central

    Zhang, Shengwei; Arfanakis, Konstantinos

    2012-01-01

    Purpose To investigate the effect of standardized and study-specific human brain diffusion tensor templates on the accuracy of spatial normalization, without ignoring the important roles of data quality and registration algorithm effectiveness. Materials and Methods Two groups of diffusion tensor imaging (DTI) datasets, with and without visible artifacts, were normalized to two standardized diffusion tensor templates (IIT2, ICBM81) as well as study-specific templates, using three registration approaches. The accuracy of inter-subject spatial normalization was compared across templates, using the most effective registration technique for each template and group of data. Results It was demonstrated that, for DTI data with visible artifacts, the study-specific template resulted in significantly higher spatial normalization accuracy than standardized templates. However, for data without visible artifacts, the study-specific template and the standardized template of higher quality (IIT2) resulted in similar normalization accuracy. Conclusion For DTI data with visible artifacts, a carefully constructed study-specific template may achieve higher normalization accuracy than that of standardized templates. However, as DTI data quality improves, a high-quality standardized template may be more advantageous than a study-specific template, since in addition to high normalization accuracy, it provides a standard reference across studies, as well as automated localization/segmentation when accompanied by anatomical labels. PMID:23034880

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carmichael, Joshua D.; Hartse, Hans

    Colocated explosive sources often produce correlated seismic waveforms. Multichannel correlation detectors identify these signals by scanning template waveforms recorded from known reference events against "target" data to find similar waveforms. This screening problem is challenged at thresholds required to monitor smaller explosions, often because non-target signals falsely trigger such detectors. Therefore, it is generally unclear what thresholds will reliably identify a target explosion while screening non-target background seismicity. Here, we estimate threshold magnitudes for hypothetical explosions located at the North Korean nuclear test site over six months of 2010, by processing International Monitoring System (IMS) array data with a multichannelmore » waveform correlation detector. Our method (1) accounts for low amplitude background seismicity that falsely triggers correlation detectors but is unidentifiable with conventional power beams, (2) adapts to diurnally variable noise levels and (3) uses source-receiver reciprocity concepts to estimate thresholds for explosions spatially separated from the template source. Furthermore, we find that underground explosions with body wave magnitudes m b = 1.66 are detectable at the IMS array USRK with probability 0.99, when using template waveforms consisting only of P -waves, without false alarms. We conservatively find that these thresholds also increase by up to a magnitude unit for sources located 4 km or more from the Feb.12, 2013 announced nuclear test.« less

  20. AIDA: ab initio domain assembly for automated multi-domain protein structure prediction and domain–domain interaction prediction

    PubMed Central

    Xu, Dong; Jaroszewski, Lukasz; Li, Zhanwen; Godzik, Adam

    2015-01-01

    Motivation: Most proteins consist of multiple domains, independent structural and evolutionary units that are often reshuffled in genomic rearrangements to form new protein architectures. Template-based modeling methods can often detect homologous templates for individual domains, but templates that could be used to model the entire query protein are often not available. Results: We have developed a fast docking algorithm ab initio domain assembly (AIDA) for assembling multi-domain protein structures, guided by the ab initio folding potential. This approach can be extended to discontinuous domains (i.e. domains with ‘inserted’ domains). When tested on experimentally solved structures of multi-domain proteins, the relative domain positions were accurately found among top 5000 models in 86% of cases. AIDA server can use domain assignments provided by the user or predict them from the provided sequence. The latter approach is particularly useful for automated protein structure prediction servers. The blind test consisting of 95 CASP10 targets shows that domain boundaries could be successfully determined for 97% of targets. Availability and implementation: The AIDA package as well as the benchmark sets used here are available for download at http://ffas.burnham.org/AIDA/. Contact: adam@sanfordburnham.org Supplementary information: Supplementary data are available at Bioinformatics online. PMID:25701568

  1. Learning-based meta-algorithm for MRI brain extraction.

    PubMed

    Shi, Feng; Wang, Li; Gilmore, John H; Lin, Weili; Shen, Dinggang

    2011-01-01

    Multiple-segmentation-and-fusion method has been widely used for brain extraction, tissue segmentation, and region of interest (ROI) localization. However, such studies are hindered in practice by their computational complexity, mainly coming from the steps of template selection and template-to-subject nonlinear registration. In this study, we address these two issues and propose a novel learning-based meta-algorithm for MRI brain extraction. Specifically, we first use exemplars to represent the entire template library, and assign the most similar exemplar to the test subject. Second, a meta-algorithm combining two existing brain extraction algorithms (BET and BSE) is proposed to conduct multiple extractions directly on test subject. Effective parameter settings for the meta-algorithm are learned from the training data and propagated to subject through exemplars. We further develop a level-set based fusion method to combine multiple candidate extractions together with a closed smooth surface, for obtaining the final result. Experimental results show that, with only a small portion of subjects for training, the proposed method is able to produce more accurate and robust brain extraction results, at Jaccard Index of 0.956 +/- 0.010 on total 340 subjects under 6-fold cross validation, compared to those by the BET and BSE even using their best parameter combinations.

  2. Classifier for gravitational-wave inspiral signals in nonideal single-detector data

    NASA Astrophysics Data System (ADS)

    Kapadia, S. J.; Dent, T.; Dal Canton, T.

    2017-11-01

    We describe a multivariate classifier for candidate events in a templated search for gravitational-wave (GW) inspiral signals from neutron-star-black-hole (NS-BH) binaries, in data from ground-based detectors where sensitivity is limited by non-Gaussian noise transients. The standard signal-to-noise ratio (SNR) and chi-squared test for inspiral searches use only properties of a single matched filter at the time of an event; instead, we propose a classifier using features derived from a bank of inspiral templates around the time of each event, and also from a search using approximate sine-Gaussian templates. The classifier thus extracts additional information from strain data to discriminate inspiral signals from noise transients. We evaluate a random forest classifier on a set of single-detector events obtained from realistic simulated advanced LIGO data, using simulated NS-BH signals added to the data. The new classifier detects a factor of 1.5-2 more signals at low false positive rates as compared to the standard "reweighted SNR" statistic, and does not require the chi-squared test to be computed. Conversely, if only the SNR and chi-squared values of single-detector events are available, random forest classification performs nearly identically to the reweighted SNR.

  3. Problem-Based Test: An "In Vitro" Experiment to Analyze the Genetic Code

    ERIC Educational Resources Information Center

    Szeberenyi, Jozsef

    2010-01-01

    Terms to be familiar with before you start to solve the test: genetic code, translation, synthetic polynucleotide, leucine, serine, filter precipitation, radioactivity measurement, template, mRNA, tRNA, rRNA, aminoacyl-tRNA synthesis, ribosomes, degeneration of the code, wobble, initiation, and elongation of protein synthesis, initiation codon.…

  4. Service-based health human resources planning for older adults.

    PubMed

    Tomblin Murphy, Gail; MacKenzie, Adrian; Rigby, Janet; Rockwood, Kenneth; Gough, Amy; Greeley, Gogi; Montpetit, Frederick; Dill, Donna; Alder, Robert; Lackie, Kelly

    2013-08-01

    To test a service-based health human resources (HHR) planning approach for older adults in the context of home and long term care (LTC); to create a practical template/tools for use in various jurisdictions and/or health care settings. The most serious health needs of seniors in 2 Canadian jurisdictions were identified and linked to the specific services and associated competencies required of health care providers (HCPs) to address those needs. The amounts of each service required were quantified and compared against the capacity of HCPs to perform the services, measured using a self-assessment survey, by using a previously developed analytical framework. Home and LTC sectors in Nova Scotia and Nunavut, Canada. Regulated and nonregulated HCPs were invited to complete either an online or paper-based competency self-assessment survey. Survey response rates in Nova Scotia and Nunavut were 11% (160 responses) and 20% (22 responses), respectively. Comparisons of the estimated number of seniors likely to need each service with the number who can be served by the workforces in each jurisdiction indicated that the workforces in both jurisdictions are sufficiently numerous, active, productive, and competent to provide most of the services likely to be required. However, significant gaps were identified in pharmacy services, ongoing client assessment, client/family education and involvement, and client/family functional and social supports. Service-based HHR planning is feasible for identifying gaps in services required by older adults, and can guide policy makers in planning hiring/recruitment, professional development, and provider education curricula. Implementation will require commitment of policy makers and other stakeholders, as well as ongoing evaluation of its effectiveness. More broadly, the ongoing effectiveness of the approach will depend on workforce planning being conducted in an iterative way, driven by regular reevaluation of population health needs and HHR effectiveness. Copyright © 2013 American Medical Directors Association, Inc. Published by Elsevier Inc. All rights reserved.

  5. TH-AB-201-10: Portal Dosimetry with Elekta IViewDose:Performance of the Simplified Commissioning Approach Versus Full Commissioning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kydonieos, M; Folgueras, A; Florescu, L

    2016-06-15

    Purpose: Elekta recently developed a solution for in-vivo EPID dosimetry (iViewDose, Elekta AB, Stockholm, Sweden) in conjunction with the Netherlands Cancer Institute (NKI). This uses a simplified commissioning approach via Template Commissioning Models (TCMs), consisting of a subset of linac-independent pre-defined parameters. This work compares the performance of iViewDose using a TCM commissioning approach with that corresponding to full commissioning. Additionally, the dose reconstruction based on the simplified commissioning approach is validated via independent dose measurements. Methods: Measurements were performed at the NKI on a VersaHD™ (Elekta AB, Stockholm, Sweden). Treatment plans were generated with Pinnacle 9.8 (Philips Medical Systems,more » Eindhoven, The Netherlands). A farmer chamber dose measurement and two EPID images were used to create a linac-specific commissioning model based on a TCM. A complete set of commissioning measurements was collected and a full commissioning model was created.The performance of iViewDose based on the two commissioning approaches was compared via a series of set-to-work tests in a slab phantom. In these tests, iViewDose reconstructs and compares EPID to TPS dose for square fields, IMRT and VMAT plans via global gamma analysis and isocentre dose difference. A clinical VMAT plan was delivered to a homogeneous Octavius 4D phantom (PTW, Freiburg, Germany). Dose was measured with the Octavius 1500 array and VeriSoft software was used for 3D dose reconstruction. EPID images were acquired. TCM-based iViewDose and 3D Octavius dose distributions were compared against the TPS. Results: For both the TCM-based and the full commissioning approaches, the pass rate, mean γ and dose difference were >97%, <0.5 and <2.5%, respectively. Equivalent gamma analysis results were obtained for iViewDose (TCM approach) and Octavius for a VMAT plan. Conclusion: iViewDose produces similar results with the simplified and full commissioning approaches. Good agreement is obtained between iViewDose (simplified approach) and the independent measurement tool. This research is funded by Elekta Limited.« less

  6. Archetype-based conversion of EHR content models: pilot experience with a regional EHR system.

    PubMed

    Chen, Rong; Klein, Gunnar O; Sundvall, Erik; Karlsson, Daniel; Ahlfeldt, Hans

    2009-07-01

    Exchange of Electronic Health Record (EHR) data between systems from different suppliers is a major challenge. EHR communication based on archetype methodology has been developed by openEHR and CEN/ISO. The experience of using archetypes in deployed EHR systems is quite limited today. Currently deployed EHR systems with large user bases have their own proprietary way of representing clinical content using various models. This study was designed to investigate the feasibility of representing EHR content models from a regional EHR system as openEHR archetypes and inversely to convert archetypes to the proprietary format. The openEHR EHR Reference Model (RM) and Archetype Model (AM) specifications were used. The template model of the Cambio COSMIC, a regional EHR product from Sweden, was analyzed and compared to the openEHR RM and AM. This study was focused on the convertibility of the EHR semantic models. A semantic mapping between the openEHR RM/AM and the COSMIC template model was produced and used as the basis for developing prototype software that performs automated bi-directional conversion between openEHR archetypes and COSMIC templates. Automated bi-directional conversion between openEHR archetype format and COSMIC template format has been achieved. Several archetypes from the openEHR Clinical Knowledge Repository have been imported into COSMIC, preserving most of the structural and terminology related constraints. COSMIC templates from a large regional installation were successfully converted into the openEHR archetype format. The conversion from the COSMIC templates into archetype format preserves nearly all structural and semantic definitions of the original content models. A strategy of gradually adding archetype support to legacy EHR systems was formulated in order to allow sharing of clinical content models defined using different formats. The openEHR RM and AM are expressive enough to represent the existing clinical content models from the template based EHR system tested and legacy content models can automatically be converted to archetype format for sharing of knowledge. With some limitations, internationally available archetypes could be converted to the legacy EHR models. Archetype support can be added to legacy EHR systems in an incremental way allowing a migration path to interoperability based on standards.

  7. Development of an IHE MRRT-compliant open-source web-based reporting platform.

    PubMed

    Pinto Dos Santos, Daniel; Klos, G; Kloeckner, R; Oberle, R; Dueber, C; Mildenberger, P

    2017-01-01

    To develop a platform that uses structured reporting templates according to the IHE Management of Radiology Report Templates (MRRT) profile, and to implement this platform into clinical routine. The reporting platform uses standard web technologies (HTML / JavaScript and PHP / MySQL) only. Several freely available external libraries were used to simplify the programming. The platform runs on a standard web server, connects with the radiology information system (RIS) and PACS, and is easily accessible via a standard web browser. A prototype platform that allows structured reporting to be easily incorporated into the clinical routine was developed and successfully tested. To date, 797 reports were generated using IHE MRRT-compliant templates (many of them downloaded from the RSNA's radreport.org website). Reports are stored in a MySQL database and are easily accessible for further analyses. Development of an IHE MRRT-compliant platform for structured reporting is feasible using only standard web technologies. All source code will be made available upon request under a free license, and the participation of other institutions in further development is welcome. • A platform for structured reporting using IHE MRRT-compliant templates is presented. • Incorporating structured reporting into clinical routine is feasible. • Full source code will be provided upon request under a free license.

  8. Porous Silicon Covered with Silver Nanoparticles as Surface-Enhanced Raman Scattering (SERS) Substrate for Ultra-Low Concentration Detection.

    PubMed

    Kosović, Marin; Balarin, Maja; Ivanda, Mile; Đerek, Vedran; Marciuš, Marijan; Ristić, Mira; Gamulin, Ozren

    2015-12-01

    Microporous and macro-mesoporous silicon templates for surface-enhanced Raman scattering (SERS) substrates were produced by anodization of low doped p-type silicon wafers. By immersion plating in AgNO3, the templates were covered with silver metallic film consisting of different silver nanostructures. Scanning electron microscopy (SEM) micrographs of these SERS substrates showed diverse morphology with significant difference in an average size and size distribution of silver nanoparticles. Ultraviolet-visible-near-infrared (UV-Vis-NIR) reflection spectroscopy showed plasmonic absorption at 398 and 469 nm, which is in accordance with the SEM findings. The activity of the SERS substrates was tested using rhodamine 6G (R6G) dye molecules and 514.5 nm laser excitation. Contrary to the microporous silicon template, the SERS substrate prepared from macro-mesoporous silicon template showed significantly broader size distribution of irregular silver nanoparticles as well as localized surface plasmon resonance closer to excitation laser wavelength. Such silver morphology has high SERS sensitivity that enables ultralow concentration detection of R6G dye molecules up to 10(-15) M. To our knowledge, this is the lowest concentration detected of R6G dye molecules on porous silicon-based SERS substrates, which might even indicate possible single molecule detection.

  9. Structural Features of a Picornavirus Polymerase Involved in the Polyadenylation of Viral RNA

    PubMed Central

    Kempf, Brian J.; Kelly, Michelle M.; Springer, Courtney L.; Peersen, Olve B.

    2013-01-01

    Picornaviruses have 3′ polyadenylated RNA genomes, but the mechanisms by which these genomes are polyadenylated during viral replication remain obscure. Based on prior studies, we proposed a model wherein the poliovirus RNA-dependent RNA polymerase (3Dpol) uses a reiterative transcription mechanism while replicating the poly(A) and poly(U) portions of viral RNA templates. To further test this model, we examined whether mutations in 3Dpol influenced the polyadenylation of virion RNA. We identified nine alanine substitution mutations in 3Dpol that resulted in shorter or longer 3′ poly(A) tails in virion RNA. These mutations could disrupt structural features of 3Dpol required for the recruitment of a cellular poly(A) polymerase; however, the structural orientation of these residues suggests a direct role of 3Dpol in the polyadenylation of RNA genomes. Reaction mixtures containing purified 3Dpol and a template RNA with a defined poly(U) sequence provided data consistent with a template-dependent reiterative transcription mechanism for polyadenylation. The phylogenetically conserved structural features of 3Dpol involved in the polyadenylation of virion RNA include a thumb domain alpha helix that is positioned in the minor groove of the double-stranded RNA product and lysine and arginine residues that interact with the phosphates of both the RNA template and product strands. PMID:23468507

  10. Comparison of Polymerase Subunits from Double-Stranded RNA Bacteriophages

    PubMed Central

    Yang, Hongyan; Makeyev, Eugene V.; Bamford, Dennis H.

    2001-01-01

    The family Cystoviridae comprises several bacteriophages with double-stranded RNA (dsRNA) genomes. We have previously purified the catalytic polymerase subunit (Pol) of one of the Cystoviridae members, bacteriophage φ6, and shown that the protein can catalyze RNA synthesis in vitro. In this reaction, both bacteriophage-specific and heterologous RNAs can serve as templates, but those containing 3′ termini from the φ6 minus strands are favored. This provides a molecular basis for the observation that only plus strands, not minus strands, are transcribed from φ6 dsRNA segments in vivo. To test whether such a regulatory mechanism is also found in other dsRNA viruses, we purified recombinant Pol subunits from the φ6-related bacteriophages φ8 and φ13 and assayed their polymerase activities in vitro. The enzymes catalyze template-dependent RNA synthesis using both single-stranded-RNA (ssRNA) and dsRNA templates. However, they differ from each other as well as from φ6 Pol in certain biochemical properties. Notably, each polymerase demonstrates a distinct preference for ssRNAs bearing short 3′-terminal sequences from the virus-specific minus strands. This suggests that, in addition to other factors, RNA transcription in Cystoviridae is controlled by the template specificity of the polymerase subunit. PMID:11602748

  11. Automatic detection of motor unit innervation zones of the external anal sphincter by multichannel surface EMG.

    PubMed

    Ullah, Khalil; Cescon, Corrado; Afsharipour, Babak; Merletti, Roberto

    2014-12-01

    A method to detect automatically the location of innervation zones (IZs) from 16-channel surface EMG (sEMG) recordings from the external anal sphincter (EAS) muscle is presented in order to guide episiotomy during child delivery. The new algorithm (2DCorr) is applied to individual motor unit action potential (MUAP) templates and is based on bidimensional cross correlation between the interpolated image of each MUAP template and two images obtained by flipping upside-down (around a horizontal axis) and left-right (around a vertical axis) the original one. The method was tested on 640 simulated MUAP templates of the sphincter muscle and compared with previously developed algorithms (Radon Transform, RT; Template Match, TM). Experimental signals were detected from the EAS of 150 subjects using an intra-anal probe with 16 equally spaced circumferential electrodes. The results of the three algorithms were compared with the actual IZ location (simulated signal) and with IZ location provided by visual analysis (VA) (experimental signals). For simulated signals, the inter quartile error range (IQR) between the estimated and the actual locations of the IZ was 0.20, 0.23, 0.42, and 2.32 interelectrode distances (IED) for the VA, 2DCorr, RT and TM methods respectively. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. GPCR-ModSim: A comprehensive web based solution for modeling G-protein coupled receptors

    PubMed Central

    Esguerra, Mauricio; Siretskiy, Alexey; Bello, Xabier; Sallander, Jessica; Gutiérrez-de-Terán, Hugo

    2016-01-01

    GPCR-ModSim (http://open.gpcr-modsim.org) is a centralized and easy to use service dedicated to the structural modeling of G-protein Coupled Receptors (GPCRs). 3D molecular models can be generated from amino acid sequence by homology-modeling techniques, considering different receptor conformations. GPCR-ModSim includes a membrane insertion and molecular dynamics (MD) equilibration protocol, which can be used to refine the generated model or any GPCR structure uploaded to the server, including if desired non-protein elements such as orthosteric or allosteric ligands, structural waters or ions. We herein revise the main characteristics of GPCR-ModSim and present new functionalities. The templates used for homology modeling have been updated considering the latest structural data, with separate profile structural alignments built for inactive, partially-active and active groups of templates. We have also added the possibility to perform multiple-template homology modeling in a unique and flexible way. Finally, our new MD protocol considers a series of distance restraints derived from a recently identified conserved network of helical contacts, allowing for a smoother refinement of the generated models which is particularly advised when there is low homology to the available templates. GPCR- ModSim has been tested on the GPCR Dock 2013 competition with satisfactory results. PMID:27166369

  13. GalaxyHomomer: a web server for protein homo-oligomer structure prediction from a monomer sequence or structure.

    PubMed

    Baek, Minkyung; Park, Taeyong; Heo, Lim; Park, Chiwook; Seok, Chaok

    2017-07-03

    Homo-oligomerization of proteins is abundant in nature, and is often intimately related with the physiological functions of proteins, such as in metabolism, signal transduction or immunity. Information on the homo-oligomer structure is therefore important to obtain a molecular-level understanding of protein functions and their regulation. Currently available web servers predict protein homo-oligomer structures either by template-based modeling using homo-oligomer templates selected from the protein structure database or by ab initio docking of monomer structures resolved by experiment or predicted by computation. The GalaxyHomomer server, freely accessible at http://galaxy.seoklab.org/homomer, carries out template-based modeling, ab initio docking or both depending on the availability of proper oligomer templates. It also incorporates recently developed model refinement methods that can consistently improve model quality. Moreover, the server provides additional options that can be chosen by the user depending on the availability of information on the monomer structure, oligomeric state and locations of unreliable/flexible loops or termini. The performance of the server was better than or comparable to that of other available methods when tested on benchmark sets and in a recent CASP performed in a blind fashion. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.

  14. Finding the ’RITE’ Acquisition Environment for Navy C2 Software

    DTIC Science & Technology

    2015-05-01

    Boiler plate contract language - Gov purpose Rights • Adding expectation of quality to contracting language • Template SOW’s created Pr...Debugger MCCABE IQ Static Analysis Cyclomatic Complexity and KSLOC. All Languages HP Fortify Security Scan STIG and Vulnerabilities Security & IA...GSSAT (GOTS) Security Scan STIG and Vulnerabilities AutoIT Automated Test Scripting Engine for Automation Functional Testing TestComplete Automated

  15. Geothermal Exploration Case Studies on OpenEI (Presentation)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Young, K.; Bennett, M.; Atkins, D.

    2014-03-01

    The U.S. Geological Survey (USGS) resource assessment (Williams et al., 2008) outlined a mean 30 GWe of undiscovered hydrothermal resource in the western United States. One goal of the U.S. Department of Energy's (DOE) Geothermal Technology Office (GTO) is to accelerate the development of this undiscovered resource. DOE has focused efforts on helping industry identify hidden geothermal resources to increase geothermal capacity in the near term. Increased exploration activity will produce more prospects, more discoveries, and more readily developable resources. Detailed exploration case studies akin to those found in oil and gas (e.g. Beaumont and Foster, 1990-1992) will give developersmore » central location for information gives models for identifying new geothermal areas, and guide efficient exploration and development of these areas. To support this effort, the National Renewable Energy Laboratory (NREL) has been working with GTO to develop a template for geothermal case studies on the Geothermal Gateway on OpenEI. In 2012, the template was developed and tested with two case studies: Raft River Geothermal Area (http://en.openei.org/wiki/Raft_River_Geothermal_Area) and Coso Geothermal Area (http://en.openei.org/wiki/Coso_Geothermal_Area). In 2013, ten additional case studies were completed, and Semantic MediaWiki features were developed to allow for more data and the direct citations of these data. These case studies are now in the process of external peer review. In 2014, NREL is working with universities and industry partners to populate additional case studies on OpenEI. The goal is to provide a large enough data set to start conducting analyses of exploration programs to identify correlations between successful exploration plans for areas with similar geologic occurrence models.« less

  16. A new approach for low-cost noninvasive detection of asymptomatic heart disease at rest.

    PubMed

    DeMarzo, Arthur P; Calvin, James E

    2007-01-01

    It would be useful to have an inexpensive, noninvasive point-of-care test for early detection of asymptomatic heart disease. This study used impedance cardiography (ICG) in a new way to assess heart function that did not use stroke volume or cardiac output. There is a model of the ICG dZ/dt waveform that may be used as a template to represent normal heart function. The hypothesis was that a dZ/dt waveform which deviates from that template should indicate heart dysfunction and therefore heart disease. The objective was to assess the accuracy of this new ICG approach, using echocardiography as the standard. Thirty-four outpatients undergoing echocardiographic testing were tested by ICG while sitting upright and supine. All patients had no symptoms or history of a structural or functional heart disorder. Echocardiographic testing showed 17 patients with abnormalities and 17 as normal. ICG testing yielded 16 true positives for heart dysfunction with 1 false negative (sensitivity = 94%) and 17 true negatives with no false positives (specificity = 100%). Considering that the cost, technical skill, and time required for this ICG test are comparable to those of an electrocardiograph, this new approach has potential as a point-of-care screening test for asymptomatic heart disease.

  17. Radio-nuclide mixture identification using medium energy resolution detectors

    DOEpatents

    Nelson, Karl Einar

    2013-09-17

    According to one embodiment, a method for identifying radio-nuclides includes receiving spectral data, extracting a feature set from the spectral data comparable to a plurality of templates in a template library, and using a branch and bound method to determine a probable template match based on the feature set and templates in the template library. In another embodiment, a device for identifying unknown radio-nuclides includes a processor, a multi-channel analyzer, and a memory operatively coupled to the processor, the memory having computer readable code stored thereon. The computer readable code is configured, when executed by the processor, to receive spectral data, to extract a feature set from the spectral data comparable to a plurality of templates in a template library, and to use a branch and bound method to determine a probable template match based on the feature set and templates in the template library.

  18. Automation of radiation treatment planning : Evaluation of head and neck cancer patient plans created by the Pinnacle3 scripting and Auto-Planning functions.

    PubMed

    Speer, Stefan; Klein, Andreas; Kober, Lukas; Weiss, Alexander; Yohannes, Indra; Bert, Christoph

    2017-08-01

    Intensity-modulated radiotherapy (IMRT) techniques are now standard practice. IMRT or volumetric-modulated arc therapy (VMAT) allow treatment of the tumor while simultaneously sparing organs at risk. Nevertheless, treatment plan quality still depends on the physicist's individual skills, experiences, and personal preferences. It would therefore be advantageous to automate the planning process. This possibility is offered by the Pinnacle 3 treatment planning system (Philips Healthcare, Hamburg, Germany) via its scripting language or Auto-Planning (AP) module. AP module results were compared to in-house scripts and manually optimized treatment plans for standard head and neck cancer plans. Multiple treatment parameters were scored to judge plan quality (100 points = optimum plan). Patients were initially planned manually by different physicists and re-planned using scripts or AP. Script-based head and neck plans achieved a mean of 67.0 points and were, on average, superior to manually created (59.1 points) and AP plans (62.3 points). Moreover, they are characterized by reproducibility and lower standard deviation of treatment parameters. Even less experienced staff are able to create at least a good starting point for further optimization in a short time. However, for particular plans, experienced planners perform even better than scripts or AP. Experienced-user input is needed when setting up scripts or AP templates for the first time. Moreover, some minor drawbacks exist, such as the increase of monitor units (+35.5% for scripted plans). On average, automatically created plans are superior to manually created treatment plans. For particular plans, experienced physicists were able to perform better than scripts or AP; thus, the benefit is greatest when time is short or staff inexperienced.

  19. Adaptive template generation for amyloid PET using a deep learning approach.

    PubMed

    Kang, Seung Kwan; Seo, Seongho; Shin, Seong A; Byun, Min Soo; Lee, Dong Young; Kim, Yu Kyeong; Lee, Dong Soo; Lee, Jae Sung

    2018-05-11

    Accurate spatial normalization (SN) of amyloid positron emission tomography (PET) images for Alzheimer's disease assessment without coregistered anatomical magnetic resonance imaging (MRI) of the same individual is technically challenging. In this study, we applied deep neural networks to generate individually adaptive PET templates for robust and accurate SN of amyloid PET without using matched 3D MR images. Using 681 pairs of simultaneously acquired 11 C-PIB PET and T1-weighted 3D MRI scans of AD, MCI, and cognitively normal subjects, we trained and tested two deep neural networks [convolutional auto-encoder (CAE) and generative adversarial network (GAN)] that produce adaptive best PET templates. More specifically, the networks were trained using 685,100 pieces of augmented data generated by rotating 527 randomly selected datasets and validated using 154 datasets. The input to the supervised neural networks was the 3D PET volume in native space and the label was the spatially normalized 3D PET image using the transformation parameters obtained from MRI-based SN. The proposed deep learning approach significantly enhanced the quantitative accuracy of MRI-less amyloid PET assessment by reducing the SN error observed when an average amyloid PET template is used. Given an input image, the trained deep neural networks rapidly provide individually adaptive 3D PET templates without any discontinuity between the slices (in 0.02 s). As the proposed method does not require 3D MRI for the SN of PET images, it has great potential for use in routine analysis of amyloid PET images in clinical practice and research. © 2018 Wiley Periodicals, Inc.

  20. Partial unfolding and refolding for structure refinement: A unified approach of geometric simulations and molecular dynamics.

    PubMed

    Kumar, Avishek; Campitelli, Paul; Thorpe, M F; Ozkan, S Banu

    2015-12-01

    The most successful protein structure prediction methods to date have been template-based modeling (TBM) or homology modeling, which predicts protein structure based on experimental structures. These high accuracy predictions sometimes retain structural errors due to incorrect templates or a lack of accurate templates in the case of low sequence similarity, making these structures inadequate in drug-design studies or molecular dynamics simulations. We have developed a new physics based approach to the protein refinement problem by mimicking the mechanism of chaperons that rehabilitate misfolded proteins. The template structure is unfolded by selectively (targeted) pulling on different portions of the protein using the geometric based technique FRODA, and then refolded using hierarchically restrained replica exchange molecular dynamics simulations (hr-REMD). FRODA unfolding is used to create a diverse set of topologies for surveying near native-like structures from a template and to provide a set of persistent contacts to be employed during re-folding. We have tested our approach on 13 previous CASP targets and observed that this method of folding an ensemble of partially unfolded structures, through the hierarchical addition of contact restraints (that is, first local and then nonlocal interactions), leads to a refolding of the structure along with refinement in most cases (12/13). Although this approach yields refined models through advancement in sampling, the task of blind selection of the best refined models still needs to be solved. Overall, the method can be useful for improved sampling for low resolution models where certain of the portions of the structure are incorrectly modeled. © 2015 Wiley Periodicals, Inc.

  1. Development and preliminary evaluation of an ultrasonic motor actuated needle guide for 3T MRI-guided transperineal prostate interventions

    NASA Astrophysics Data System (ADS)

    Song, Sang-Eun; Tokuda, Junichi; Tuncali, Kemal; Tempany, Clare; Hata, Nobuhiko

    2012-02-01

    Image guided prostate interventions have been accelerated by Magnetic Resonance Imaging (MRI) and robotic technologies in the past few years. However, transrectal ultrasound (TRUS) guided procedure still remains as vast majority in clinical practice due to engineering and clinical complexity of the MRI-guided robotic interventions. Subsequently, great advantages and increasing availability of MRI have not been utilized at its maximum capacity in clinic. To benefit patients from the advantages of MRI, we developed an MRI-compatible motorized needle guide device "Smart Template" that resembles a conventional prostate template to perform MRI-guided prostate interventions with minimal changes in the clinical procedure. The requirements and specifications of the Smart Template were identified from our latest MRI-guided intervention system that has been clinically used in manual mode for prostate biopsy. Smart Template consists of vertical and horizontal crossbars that are driven by two ultrasonic motors via timing-belt and mitergear transmissions. Navigation software that controls the crossbar position to provide needle insertion positions was also developed. The software can be operated independently or interactively with an open-source navigation software, 3D Slicer, that has been developed for prostate intervention. As preliminary evaluation, MRI distortion and SNR test were conducted. Significant MRI distortion was found close to the threaded brass alloy components of the template. However, the affected volume was limited outside the clinical region of interest. SNR values over routine MRI scan sequences for prostate biopsy indicated insignificant image degradation during the presence of the robotic system and actuation of the ultrasonic motors.

  2. Coordination polymer nanocapsules prepared using metal-organic framework templates for pH-responsive drug delivery

    NASA Astrophysics Data System (ADS)

    Tang, Lei; Shi, Jiafu; Wang, Xiaoli; Zhang, Shaohua; Wu, Hong; Sun, Hongfan; Jiang, Zhongyi

    2017-07-01

    A facile, efficient, and versatile approach is presented to synthesize pH-responsive nanocapsules (˜120 nm) by combining the advantages of metal-organic frameworks (MOFs) and metal-organic thin films. ZIF-8 nanoparticles are used as templates on which a thin film coating of iron(III)-catechol complexes is derived from the coordination between dopamine-modified alginate (AlgDA) and iron(III) ions. After the template removal, nanocapsules with a pH-responsive wall are obtained. Doxorubicin (Dox), a typical anticancer drug, is first immobilized in ZIF-8 frameworks through coprecipitation and then encapsulated in nanocapsules after the removal of ZIF-8. The structure of the iron(III)-catechol complex varies with pH value, thus conferring the Dox@Nanocapsules with tailored release behavior in vitro. Cytotoxicity tests illustrate the highly effective cytotoxicity of Dox@Nanocapsules towards cancer cells. This study provides a new method for preparing smart nanocapsules and offers more opportunities for the controlled delivery of drugs.

  3. Low-Temperature Fluorination of Soft-Templated Mesoporous Carbons for a High-Power Lithium/Carbon Fluoride Battery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fulvio, Pasquale F.; Brown, Suree S.; Adcock, Jamie

    Soft-templated mesoporous carbons and activated mesoporous carbons were fluorinated using elemental fluorine between room temperature and 235 °C. The mesoporous carbons were prepared via self-assembly synthesis of phloroglucinol–formaldehyde as a carbon precursor in the presence of triblock ethylene oxide–propylene oxide–ethylene oxide copolymer BASF Pluronic F127 as the template. The F/C ratios ranged from ~0.15 to 0.75 according to gravimetric, energy dispersive X-ray spectroscopy, and X-ray photoelectron spectroscopy analysis. Materials have mesopore diameters up to 11 nm and specific surface areas as high as 850 m² g⁻¹ after fluorination as calculated from nitrogen adsorption isotherms at -196 °C. Furthermore, the materialsmore » exhibit higher discharge potentials and energy and power densities as well as faster reaction kinetics under high current densities than commercial carbon fluorides with similar fluorine contents when tested as cathodes for Li/CF x batteries.« less

  4. Low-Temperature Fluorination of Soft-Templated Mesoporous Carbons for a High-Power Lithium/Carbon Fluoride Battery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fulvio, Pasquale F; Dai, Sheng; Guo, Bingkun

    Soft-templated mesoporous carbons and activated mesoporous carbons were fluorinated using elemental fluorine between room temperature and 235 C. The mesoporous carbons were prepared via self-assembly synthesis of phloroglucinol formaldehyde as a carbon precursor in the presence of triblock ethylene oxide propylene oxide ethylene oxide copolymer BASF Pluronic F127 as the template. The F/C ratios ranged from 0.15 to 0.75 according to gravimetric, energy dispersive X-ray spectroscopy, and X-ray photoelectron spectroscopy analysis. Materials have mesopore diameters up to 11 nm and specific surface areas as high as 850 m2 g 1 after fluorination as calculated from nitrogen adsorption isotherms at 196more » C. Furthermore, the materials exhibit higher discharge potentials and energy and power densities as well as faster reaction kinetics under high current densities than commercial carbon fluorides with similar fluorine contents when tested as cathodes for Li/CFx batteries.« less

  5. The Unifying Moral Dyad: Liberals and Conservatives Share the Same Harm-Based Moral Template.

    PubMed

    Schein, Chelsea; Gray, Kurt

    2015-08-01

    Do moral disagreements regarding specific issues (e.g., patriotism, chastity) reflect deep cognitive differences (i.e., distinct cognitive mechanisms) between liberals and conservatives? Dyadic morality suggests that the answer is "no." Despite moral diversity, we reveal that moral cognition--in both liberals and conservatives--is rooted in a harm-based template. A dyadic template suggests that harm should be central within moral cognition, an idea tested--and confirmed--through six specific hypotheses. Studies suggest that moral judgment occurs via dyadic comparison, in which counter-normative acts are compared with a prototype of harm. Dyadic comparison explains why harm is the most accessible and important of moral content, why harm organizes--and overlaps with--diverse moral content, and why harm best translates across moral content. Dyadic morality suggests that various moral content (e.g., loyalty, purity) are varieties of perceived harm and that past research has substantially exaggerated moral differences between liberals and conservatives. © 2015 by the Society for Personality and Social Psychology, Inc.

  6. Vega is first offshore development for Montedison

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1985-10-01

    Montedison's Vega field, 15 miles off the southern tip of Sicily, has recoverable oil reserves of 400 million bbl. This is Montedison's first offshore development venture, although the operator has considerable onshore experience. It will be followed by a second field, the smaller Mila floating production system, also off Sicily. One platform will be placed on a template installed in 1983 with up to 18 pre-drilled wells in water depths of 480 ft. The field may hold up to 1 billion bbl of 16/sup 0/ crude, but geology is complex and heavily fractured. The template has 30 available drilling slots,more » and water injection is being considered. The Vega discovery well was drilled in 1980, with 5000 b/d tested from 1000-ft oil column in Strep-penosa shales. Subsequently five wells were drilled by the Glomar Biscay I semi. These wells were drilled to a depth of just over 8000 ft with a total deviation of 60/sup 0/. The template is the first in the Mediterranean.« less

  7. Comparison of statistical algorithms for detecting homogeneous river reaches along a longitudinal continuum

    NASA Astrophysics Data System (ADS)

    Leviandier, Thierry; Alber, A.; Le Ber, F.; Piégay, H.

    2012-02-01

    Seven methods designed to delineate homogeneous river segments, belonging to four families, namely — tests of homogeneity, contrast enhancing, spatially constrained classification, and hidden Markov models — are compared, firstly on their principles, then on a case study, and on theoretical templates. These templates contain patterns found in the case study but not considered in the standard assumptions of statistical methods, such as gradients and curvilinear structures. The influence of data resolution, noise and weak satisfaction of the assumptions underlying the methods is investigated. The control of the number of reaches obtained in order to achieve meaningful comparisons is discussed. No method is found that outperforms all the others on all trials. However, the methods with sequential algorithms (keeping at order n + 1 all breakpoints found at order n) fail more often than those running complete optimisation at any order. The Hubert-Kehagias method and Hidden Markov Models are the most successful at identifying subpatterns encapsulated within the templates. Ergodic Hidden Markov Models are, moreover, liable to exhibit transition areas.

  8. Templated synthesis of plate-like MoS2 nanosheets assisted with HNTs and their tribological performance in oil

    NASA Astrophysics Data System (ADS)

    Wu, Pei-Rong; Cheng, Zhi-Lin; Kong, Ying-Chao; Ma, Zhan-Sheng; Liu, Zan

    2018-05-01

    Two-dimensional MoS2 nanosheets were synthesized by using halloysite nanotubes (HNTs) as template under the hydrothermal synthesis. The structure and morphology of the as-synthesized MoS2 nanosheets were determined by a series of characterizations. The results showed that the as-synthesized MoS2 nanosheets were of the plate-like structure with about five layers, and the basal spacing was about 0.63 nm. It was demonstrated that HNTs played a crucial template role in the formation of the plate-like MoS2 nanosheets. The formation mechanism was proposed. Furthermore, the tribological performance of the as-prepared MoS2 nanosheets in oil was intensively examined on the ball-on-ball wear tester. The testing results verified that the as-prepared MoS2 nanosheets as additive could significantly improve the friction performance of oil, which exhibited the good antifriction, antiwear, and load-carrying properties.

  9. Synthetic incoherent feedforward circuits show adaptation to the amount of their genetic template

    PubMed Central

    Bleris, Leonidas; Xie, Zhen; Glass, David; Adadey, Asa; Sontag, Eduardo; Benenson, Yaakov

    2011-01-01

    Natural and synthetic biological networks must function reliably in the face of fluctuating stoichiometry of their molecular components. These fluctuations are caused in part by changes in relative expression efficiency and the DNA template amount of the network-coding genes. Gene product levels could potentially be decoupled from these changes via built-in adaptation mechanisms, thereby boosting network reliability. Here, we show that a mechanism based on an incoherent feedforward motif enables adaptive gene expression in mammalian cells. We modeled, synthesized, and tested transcriptional and post-transcriptional incoherent loops and found that in all cases the gene product adapts to changes in DNA template abundance. We also observed that the post-transcriptional form results in superior adaptation behavior, higher absolute expression levels, and lower intrinsic fluctuations. Our results support a previously hypothesized endogenous role in gene dosage compensation for such motifs and suggest that their incorporation in synthetic networks will improve their robustness and reliability. PMID:21811230

  10. Tectonic tremor and LFEs on a reverse fault in Taiwan

    DOE PAGES

    Aguiar, Ana C.; Chao, Kevin; Beroza, Gregory C.

    2017-06-16

    In this paper, we compare low-frequency earthquakes (LFEs) from triggered and ambient tremor under the southern Central Range, Taiwan. We apply the PageRank algorithm used by Aguiar and Beroza (2014) that exploits the repetitive nature of the LFEs to find repeating LFEs in both ambient and triggered tremor. We use these repeaters to create LFE templates and find that the templates created from both tremor types are very similar. To test their similarity, we use both interchangeably and find that most of both the ambient and triggered tremor match the LFE templates created from either data set, suggesting that LFEsmore » for both events have a common origin. Finally, we locate the LFEs by using local earthquake P wave and S wave information and find that LFEs from triggered and ambient tremor locate to between 20 and 35 km on what we interpret as the deep extension of the Chaochou-Lishan Fault.« less

  11. Development of Total Knee Replacement Digital Templating Software

    NASA Astrophysics Data System (ADS)

    Yusof, Siti Fairuz; Sulaiman, Riza; Thian Seng, Lee; Mohd. Kassim, Abdul Yazid; Abdullah, Suhail; Yusof, Shahril; Omar, Masbah; Abdul Hamid, Hamzaini

    In this study, by taking full advantage of digital X-ray and computer technology, we have developed a semi-automated procedure to template knee implants, by making use of digital templating method. Using this approach, a software system called OrthoKneeTMhas been designed and developed. The system is to be utilities as a study in the Department of Orthopaedic and Traumatology in medical faculty, UKM (FPUKM). OrthoKneeTMtemplating process employs uses a technique similar to those used by many surgeons, using acetate templates over X-ray films. Using template technique makes it easy to template various implant from every Implant manufacturers who have with a comprehensive database of templates. The templating functionality includes, template (knee) and manufactures templates (Smith & Nephew; and Zimmer). From an image of patient x-ray OrthoKneeTMtemplates help in quickly and easily reads to the approximate template size needed. The visual templating features then allow us quickly review multiple template sizes against the X-ray and thus obtain the nearly precise view of the implant size required. The system can assist by templating on one patient image and will generate reports that can accompany patient notes. The software system was implemented in Visual basic 6.0 Pro using the object-oriented techniques to manage the graphics and objects. The approaches for image scaling will be discussed. Several of measurement in orthopedic diagnosis process have been studied and added in this software as measurement tools features using mathematic theorem and equations. The study compared the results of the semi-automated (using digital templating) method to the conventional method to demonstrate the accuracy of the system.

  12. Performance Portability Strategies for Grid C++ Expression Templates

    NASA Astrophysics Data System (ADS)

    Boyle, Peter A.; Clark, M. A.; DeTar, Carleton; Lin, Meifeng; Rana, Verinder; Vaquero Avilés-Casco, Alejandro

    2018-03-01

    One of the key requirements for the Lattice QCD Application Development as part of the US Exascale Computing Project is performance portability across multiple architectures. Using the Grid C++ expression template as a starting point, we report on the progress made with regards to the Grid GPU offloading strategies. We present both the successes and issues encountered in using CUDA, OpenACC and Just-In-Time compilation. Experimentation and performance on GPUs with a SU(3)×SU(3) streaming test will be reported. We will also report on the challenges of using current OpenMP 4.x for GPU offloading in the same code.

  13. Enhanced ICBM Diffusion Tensor Template of the Human Brain

    PubMed Central

    Zhang, Shengwei; Peng, Huiling; Dawe, Robert J.; Arfanakis, Konstantinos

    2010-01-01

    Development of a diffusion tensor (DT) template that is representative of the micro-architecture of the human brain is crucial for comparisons of neuronal structural integrity and brain connectivity across populations, as well as for the generation of a detailed white matter atlas. Furthermore, a DT template in ICBM space may simplify consolidation of information from DT, anatomical and functional MRI studies. The previously developed “IIT DT brain template” was produced in ICBM-152 space, based on a large number of subjects from a limited age-range, using data with minimal image artifacts, and non-linear registration. That template was characterized by higher image sharpness, provided the ability to distinguish smaller white matter fiber structures, and contained fewer image artifacts, than several previously published DT templates. However, low-dimensional registration was used in the development of that template, which led to a mismatch of DT information across subjects, eventually manifested as loss of local diffusion information and errors in the final tensors. Also, low-dimensional registration led to a mismatch of the anatomy in the IIT and ICBM-152 templates. In this work, a significantly improved DT brain template in ICBM-152 space was developed, using high-dimensional non-linear registration and the raw data collected for the purposes of the IIT template. The accuracy of inter-subject DT matching was significantly increased compared to that achieved for the development of the IIT template. Consequently, the new template contained DT information that was more representative of single-subject human brain data, and was characterized by higher image sharpness than the IIT template. Furthermore, a bootstrap approach demonstrated that the variance of tensor characteristics was lower in the new template. Additionally, compared to the IIT template, brain anatomy in the new template more accurately matched ICBM-152 space. Finally, spatial normalization of a number of DT datasets through registration to the new and existing IIT templates was improved when using the new template. PMID:20851772

  14. Comparison of static and dynamic computer-assisted guidance methods in implantology.

    PubMed

    Mischkowski, R A; Zinser, M J; Neugebauer, J; Kübler, A C; Zöller, J E

    2006-01-01

    The planning of dental implant position and its transfer to the operation site can be considered as one of the most important factors for the long-term success of implant-supported prosthetic and epithetic restorations. This study compares computer-assisted fabricated surgical templates as the static method with intro-operative image guided navigation as the dynamic method for transfer of three-dimensional pre-operative planning. For the static method, the systems Med3D, coDiagnostix/ gonyX, and SimPlant were used. For the dynamic method, the systems RoboDent und VectorVision2 were applied. A total of 746 implants were inserted between August 1999 and December 2005 in 206 patients. The static approach was used most frequently, accounting for 611 fixtures in 168 patients. The failure ratios within the first 6 months were 1.31% in the statically controlled insertion group compared to 2.96% in the dynamically controlled insertion group. Complications related to an incorrect position of the implants have not been observed so far in either group. All computer-assisted methods included in this study were successfully applied in a clinical setting after a certain start-up period. The indications for application of computer-assisted methods in implantology are currently given in difficult anatomical situations. Due to uncomplicated handling and low resource demands, the static template technique can be recommended as the method of choice for the majority of all cases falling into this category.

  15. NASA's Planetary Data System: Support for the Delivery of Derived Data Sets at the Atmospheres Node

    NASA Astrophysics Data System (ADS)

    Chanover, Nancy J.; Beebe, Reta; Neakrase, Lynn; Huber, Lyle; Rees, Shannon; Hornung, Danae

    2015-11-01

    NASA’s Planetary Data System is charged with archiving electronic data products from NASA planetary missions that are sponsored by NASA’s Science Mission Directorate. This archive, currently organized by science disciplines, uses standards for describing and storing data that are designed to enable future scientists who are unfamiliar with the original experiments to analyze the data, and to do this using a variety of computer platforms, with no additional support. These standards address the data structure, description contents, and media design. The new requirement in the NASA ROSES-2015 Research Announcement to include a Data Management Plan will result in an increase in the number of derived data sets that are being delivered to the PDS. These data sets may come from the Planetary Data Archiving, Restoration and Tools (PDART) program, other Data Analysis Programs (DAPs) or be volunteered by individuals who are publishing the results of their analysis. In response to this increase, the PDS Atmospheres Node is developing a set of guidelines and user tools to make the process of archiving these derived data products more efficient. Here we provide a description of Atmospheres Node resources, including a letter of support for the proposal stage, a communication schedule for the planned archive effort, product label samples and templates in extensible markup language (XML), documentation templates, and validation tools necessary for producing a PDS4-compliant derived data bundle(s) efficiently and accurately.

  16. Three-dimensional printing and computer navigation assisted hemipelvectomy for en bloc resection of osteochondroma

    PubMed Central

    Zhang, Yaqing; Wen, Lianjiang; Zhang, Jun; Yan, Guoliang; Zhou, Yue; Huang, Bo

    2017-01-01

    Abstract Rationale: Three-dimensional (3D) printed templates can be designed to match an individual's anatomy, allowing surgeons to refine preoperative planning. In addition, the use of computer navigation (NAV) is gaining popularity to improve surgical accuracy in the resection of pelvic tumors. However, its use in combination with 3D printing to assist complex pelvic tumor resection has not been reported. Patient concerns: A 36-year-old man presented with left-sided pelvic pain and a fast-growing mass. He also complained of a 3-month history of radiating pain and numbness in the lower left extremity. Diagnoses: A biopsy revealed an osteochondroma with malignant potential. This osteochondroma arises from the ilium and involves the sacrum and lower lumbar vertebrae. Interventions: Here, we describe a novel combined application of 3D printing and intraoperative NAV systems to guide hemipelvectomy for en-bloc resection of the osteochondroma. The 3D printed template is analyzed during surgical planning and guides the initial intraoperative bone work to improve surgical accuracy and efficiency, while a computer NAV system provides real-time imaging during the tumor removal to achieve adequate resection margins and minimize the likelihood of injury to adjacent critical structures. Outcomes: The tumor mass and the invaded spinal structures were removed en bloc. Lessons: The combined application of 3D printing and computer NAV may be useful for tumor targeting and safe osteotomies in pelvic tumor surgery. PMID:28328842

  17. Functional Programming with C++ Template Metaprograms

    NASA Astrophysics Data System (ADS)

    Porkoláb, Zoltán

    Template metaprogramming is an emerging new direction of generative programming. With the clever definitions of templates we can force the C++ compiler to execute algorithms at compilation time. Among the application areas of template metaprograms are the expression templates, static interface checking, code optimization with adaption, language embedding and active libraries. However, as template metaprogramming was not an original design goal, the C++ language is not capable of elegant expression of metaprograms. The complicated syntax leads to the creation of code that is hard to write, understand and maintain. Although template metaprogramming has a strong relationship with functional programming, this is not reflected in the language syntax and existing libraries. In this paper we give a short and incomplete introduction to C++ templates and the basics of template metaprogramming. We will enlight the role of template metaprograms, and some important and widely used idioms. We give an overview of the possible application areas as well as debugging and profiling techniques. We suggest a pure functional style programming interface for C++ template metaprograms in the form of embedded Haskell code which is transformed to standard compliant C++ source.

  18. Interpretation of coagulation test results using a web-based reporting system.

    PubMed

    Quesada, Andres E; Jabcuga, Christine E; Nguyen, Alex; Wahed, Amer; Nedelcu, Elena; Nguyen, Andy N D

    2014-01-01

    Web-based synoptic reporting has been successfully integrated into diverse fields of pathology, improving efficiency and reducing typographic errors. Coagulation is a challenging field for practicing pathologists and pathologists-in-training alike. To develop a Web-based program that can expedite the generation of a individualized interpretive report for a variety of coagulation tests. We developed a Web-based synoptic reporting system composed of 119 coagulation report templates and 38 thromboelastography (TEG) report templates covering a wide range of findings. Our institution implemented this reporting system in July 2011; it is currently used by pathology residents and attending pathologists. Feedback from the users of these reports have been overwhelmingly positive. Surveys note the time saved and reduced errors. Our easily accessible, user-friendly, Web-based synoptic reporting system for coagulation is a valuable asset to our laboratory services. Copyright© by the American Society for Clinical Pathology (ASCP).

  19. A multi-level rapid prototyping drill guide template reduces the perforation risk of pedicle screw placement in the lumbar and sacral spine.

    PubMed

    Merc, Matjaz; Drstvensek, Igor; Vogrin, Matjaz; Brajlih, Tomaz; Recnik, Gregor

    2013-07-01

    The method of free-hand pedicle screw placement is generally safe although it carries potential risks. For this reason, several highly accurate computer-assisted systems were developed and are currently on the market. However, these devices have certain disadvantages. We have developed a method of pedicle screw placement in the lumbar and sacral region using a multi-level drill guide template, created with the rapid prototyping technology and have validated it in a clinical study. The aim of the study was to manufacture and evaluate the accuracy of a multi-level drill guide template for lumbar and first sacral pedicle screw placement and to compare it with the free-hand technique under fluoroscopy supervision. In 2011 and 2012, a randomized clinical trial was performed on 20 patients. 54 screws were implanted in the trial group using templates and 54 in the control group using the fluoroscopy-supervised free-hand technique. Furthermore, applicability for the first sacral level was tested. Preoperative CT-scans were taken and templates were designed using the selective laser sintering method. Postoperative evaluation and statistical analysis of pedicle violation, displacement, screw length and deviation were performed for both groups. The incidence of cortex perforation was significantly reduced in the template group; likewise, the deviation and displacement level of screws in the sagittal plane. In both groups there was no significantly important difference in deviation and displacement level in the transversal plane as not in pedicle screw length. The results for the first sacral level resembled the main investigated group. The method significantly lowers the incidence of cortex perforation and is therefore potentially applicable in clinical practice, especially in some selected cases. The applied method, however, carries a potential for errors during manufacturing and practical usage and therefore still requires further improvements.

  20. Comparing Recent Organizing Templates for Test Content between ACS Exams in General Chemistry and AP Chemistry

    ERIC Educational Resources Information Center

    Holme, Thomas

    2014-01-01

    Two different versions of "big ideas" rooted content maps have recently been published for general chemistry. As embodied in the content outline from the College Board, one of these maps is designed to guide curriculum development and testing for advanced placement (AP) chemistry. The Anchoring Concepts Content Map for general chemistry…

  1. Problem-solving test: catalytic activities of a human nuclear enzyme.

    PubMed

    Szeberényi, József

    2011-01-01

    Terms to be familiar with before you start to solve the test: ion exchange chromatography, polynucleotides, oligonucleotides, radioactive labeling, template, primer, DNA polymerase, reverse transcriptase, helicase, nucleoside triphosphates, nucleoside diphosphates, nucleoside monophosphates, nucleosides, 5′-end and 3′-end, bacteriophage, polyacrylamide gel electrophoresis, urea, autoradiography, proofreading, telomerase, endonucleases, exonucleases, primase, topoisomerases, and excinuclease.

  2. Web-Based Testing: A Form-Based Template for Creating Multimedia Enhanced Tests.

    ERIC Educational Resources Information Center

    MacDougall, Glenn; Place, Craig; Currie, Duane

    Acadia University (Nova Scotia) has completed year two of the Acadia Advantage initiative, which involved 1,500 students and 170 faculty using IBM notebook computers in the curriculum. By year 2000, all 4,000 students at Acadia University will have notebook computers and will be taking part in technology-enhanced courses. To assist faculty, the…

  3. Unbiased methods for removing systematics from galaxy clustering measurements

    NASA Astrophysics Data System (ADS)

    Elsner, Franz; Leistedt, Boris; Peiris, Hiranya V.

    2016-02-01

    Measuring the angular clustering of galaxies as a function of redshift is a powerful method for extracting information from the three-dimensional galaxy distribution. The precision of such measurements will dramatically increase with ongoing and future wide-field galaxy surveys. However, these are also increasingly sensitive to observational and astrophysical contaminants. Here, we study the statistical properties of three methods proposed for controlling such systematics - template subtraction, basic mode projection, and extended mode projection - all of which make use of externally supplied template maps, designed to characterize and capture the spatial variations of potential systematic effects. Based on a detailed mathematical analysis, and in agreement with simulations, we find that the template subtraction method in its original formulation returns biased estimates of the galaxy angular clustering. We derive closed-form expressions that should be used to correct results for this shortcoming. Turning to the basic mode projection algorithm, we prove it to be free of any bias, whereas we conclude that results computed with extended mode projection are biased. Within a simplified setup, we derive analytical expressions for the bias and discuss the options for correcting it in more realistic configurations. Common to all three methods is an increased estimator variance induced by the cleaning process, albeit at different levels. These results enable unbiased high-precision clustering measurements in the presence of spatially varying systematics, an essential step towards realizing the full potential of current and planned galaxy surveys.

  4. Computer-aided osteotomy design for harvesting autologous bone grafts in reconstructive surgery

    NASA Astrophysics Data System (ADS)

    Krol, Zdzislaw; Zerfass, Peter; von Rymon-Lipinski, Bartosz; Jansen, Thomas; Hauck, Wolfgang; Zeilhofer, Hans-Florian U.; Sader, Robert; Keeve, Erwin

    2001-05-01

    Autologous grafts serve as the standard grafting material in the treatment of maxillofacial bone tumors, traumatic defects or congenital malformations. The pre-selection of a donor site depends primarily on the morphological fit of the available bone mass and the shape of the part that has to be transplanted. To achieve sufficient incorporation of the autograft into the host bone, precise planning and simulation of the surgical intervention based on 3D CT studies is required. This paper presents a method to identify an optimal donor site by performing an optimization of appropriate similarity measures between donor region and a given transplant. At the initial stage the surgeon has to delineate the osteotomy border lines in the template CT data set and to define a set of constraints for the optimization of appropriate similarity measures between donor region and a given transplant. At the initial stage the surgeon has to delineate the osteotomy border lines in the template CT data set and to define a set of constraints for the optimization task in the donor site CT data set. The following fully automatic optimization stage delivers a set of sub-optimal and optimal donor sites for a given template. All generated solutions can be explored interactively on the computer display using an efficient graphical interface. Reconstructive operations supported by our system were performed on 28 patients. We found that the operation time can be considerably shortened by this approach.

  5. Issues Facing Pharmacy Leaders in 2015: Suggestions for Pharmacy Strategic Planning

    PubMed Central

    Weber, Robert J.

    2015-01-01

    Issues facing pharmacy leaders in 2015 include practice model growth and the role of pharmacy students, clinical privileging of health-system pharmacists and provider status, medication error prevention, and specialty pharmacy services. The goal of this article is to provide practical approaches to 4 issues facing pharmacy leaders in 2015 to help them focus their department’s goals. This article will address (1) advances in the pharmacy practice model initiative and the role of pharmacy students, (2) the current thinking of pharmacists being granted clinical privileges in health systems, (3) updates on preventing harmful medication errors, and (4) the growth of specialty pharmacy services. The sample template of a strategic plan may be used by a pharmacy department in 2015 in an effort to continue developing patient-centered pharmacy services. PMID:25717212

  6. Template-switching during DNA synthesis by Thermus aquaticus DNA polymerase I.

    PubMed Central

    Odelberg, S J; Weiss, R B; Hata, A; White, R

    1995-01-01

    Recombinant DNA molecules are often generated during the polymerase chain reaction (PCR) when partially homologous templates are available [e.g., see Pääbo et al. (1990) J. Biol. Chem. 265, 4718-4721]. It has been suggested that these recombinant molecules are a consequence of truncated extension products annealing to partially homologous templates on subsequent PCR cycles. However, we demonstrate here that recombinants can be generated during a single round of primer extension in the absence of subsequent heat denaturation, indicating that template-switching produces some of these recombinant molecules. Two types of template-switches were observed: (i) switches to pre-existing templates and (ii) switches to the complementary nascent strand. Recombination is reduced several fold when the complementary template strands are physically separated by attachment to streptavidin magnetic beads. This result supports the hypothesis that either the polymerase or at least one of the two extending strands switches templates during DNA synthesis and that interaction between the complementary template strands is necessary for efficient template-switching. Images PMID:7596836

  7. Virtual surgical planning and 3D printing in prosthetic orbital reconstruction with percutaneous implants: a technical case report

    PubMed Central

    Huang, Yu-Hui; Seelaus, Rosemary; Zhao, Linping; Patel, Pravin K; Cohen, Mimis

    2016-01-01

    Osseointegrated titanium implants to the cranial skeleton for retention of facial prostheses have proven to be a reliable replacement for adhesive systems. However, improper placement of the implants can jeopardize prosthetic outcomes, and long-term success of an implant-retained prosthesis. Three-dimensional (3D) computer imaging, virtual planning, and 3D printing have become accepted components of the preoperative planning and design phase of treatment. Computer-aided design and computer-assisted manufacture that employ cone-beam computed tomography data offer benefits to patient treatment by contributing to greater predictability and improved treatment efficiencies with more reliable outcomes in surgical and prosthetic reconstruction. 3D printing enables transfer of the virtual surgical plan to the operating room by fabrication of surgical guides. Previous studies have shown that accuracy improves considerably with guided implantation when compared to conventional template or freehand implant placement. This clinical case report demonstrates the use of a 3D technological pathway for preoperative virtual planning through prosthesis fabrication, utilizing 3D printing, for a patient with an acquired orbital defect that was restored with an implant-retained silicone orbital prosthesis. PMID:27843356

  8. Virtual surgical planning and 3D printing in prosthetic orbital reconstruction with percutaneous implants: a technical case report.

    PubMed

    Huang, Yu-Hui; Seelaus, Rosemary; Zhao, Linping; Patel, Pravin K; Cohen, Mimis

    2016-01-01

    Osseointegrated titanium implants to the cranial skeleton for retention of facial prostheses have proven to be a reliable replacement for adhesive systems. However, improper placement of the implants can jeopardize prosthetic outcomes, and long-term success of an implant-retained prosthesis. Three-dimensional (3D) computer imaging, virtual planning, and 3D printing have become accepted components of the preoperative planning and design phase of treatment. Computer-aided design and computer-assisted manufacture that employ cone-beam computed tomography data offer benefits to patient treatment by contributing to greater predictability and improved treatment efficiencies with more reliable outcomes in surgical and prosthetic reconstruction. 3D printing enables transfer of the virtual surgical plan to the operating room by fabrication of surgical guides. Previous studies have shown that accuracy improves considerably with guided implantation when compared to conventional template or freehand implant placement. This clinical case report demonstrates the use of a 3D technological pathway for preoperative virtual planning through prosthesis fabrication, utilizing 3D printing, for a patient with an acquired orbital defect that was restored with an implant-retained silicone orbital prosthesis.

  9. Urban planning for healthy cities. A review of the progress of the European Healthy Cities Programme.

    PubMed

    Barton, Hugh; Grant, Marcus

    2013-10-01

    The purpose of this paper is to evaluate the progress made by European cities in relation to Healthy Urban Planning (HUP) during Phase IV of the World Health Organization's Healthy Cities programme (2003-2008). The introduction sets out the general principle of HUP, identifying three levels or phases of health and planning integration. This leads on to a more specific analysis of the processes and substance of HUP, which provide criteria for assessment of progress. The assessment itself relies on two sources of data provided by the municipalities: the Annual Review Templates (ARTs) 2008 and the response to the Phase IV General Evaluation Questionnaire. The findings indicate that the evidence from different sources and questions in different sections are encouragingly consistent. The number of cities achieving a good level of understanding and activity in HUP has risen very substantially over the period. In particular, those achieving effective strategic integration of health and planning have increased. A key challenge for the future will be to develop planning frameworks which advance public health concerns in a spatial policy context driven often by market forces. A health in all policies approach could be valuable.

  10. Population differences in brain morphology: Need for population specific brain template.

    PubMed

    Rao, Naren P; Jeelani, Haris; Achalia, Rashmin; Achalia, Garima; Jacob, Arpitha; Bharath, Rose Dawn; Varambally, Shivarama; Venkatasubramanian, Ganesan; K Yalavarthy, Phaneendra

    2017-07-30

    Brain templates provide a standard anatomical platform for population based morphometric assessments. Typically, standard brain templates for such assessments are created using Caucasian brains, which may not be ideal to analyze brains from other ethnicities. To effectively demonstrate this, we compared brain morphometric differences between T1 weighted structural MRI images of 27 healthy Indian and Caucasian subjects of similar age and same sex ratio. Furthermore, a population specific brain template was created from MRI images of healthy Indian subjects and compared with standard Montreal Neurological Institute (MNI-152) template. We also examined the accuracy of registration of by acquiring a different T1 weighted MRI data set and registering them to newly created Indian template and MNI-152 template. The statistical analysis indicates significant difference in global brain measures and regional brain structures of Indian and Caucasian subjects. Specifically, the global brain measurements of the Indian brain template were smaller than that of the MNI template. Also, Indian brain images were better realigned to the newly created template than to the MNI-152 template. The notable variations in Indian and Caucasian brains convey the need to build a population specific Indian brain template and atlas. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  11. Development and Testing of a Smartphone Application Prototype for Oral Health Promotion.

    PubMed

    Nolen, Sara L; Giblin-Scanlon, Lori J; Boyd, Linda D; Rainchuso, Lori

    2018-04-01

    Purpose: The purpose of this study was to develop and test a smartphone application (app) prototype, ToothSense, as an oral health promotion tool for the prevention of Early Childhood Caries (ECC) based on the Theory of Planned Behavior (TPB). Methods: A quantitative and qualitative design process based on the TPB was used for the app development in the first phase of the study. A behavioral intervention technologic model was used to document the app features design, accounting for Doshi's intervention strategies for the TPB. Beta-testing of the app was hosted via an online software program. Testers were presented with a series of tasks and prompts followed by a 5-point Likert-scale questionnaire that quantitatively measured perceptions of the app's interactive design based on Jakob Nielsen's principles and behavioral strategies. A Net Promotor Score was calculated to determine the tester's likelihood to recommend the app prototype. Audio and video aspects of the app were qualitatively measured using a template approach. Results: Beta testers agreed the app met the majority of the five usability statements. The Net Promotor Score indicated a likelihood to recommend the app prototype. Thematic analyses revealed the following themes: interface design, navigation, terminology, information, and oral health promotion. Conclusion: Beta testing results from this study provided health promotion project design information for the prevention of ECC using the TPB and highlighted the importance and usability of smartphone app for oral health promotion. Copyright © 2018 The American Dental Hygienists’ Association.

  12. Development of nanoimprint lithography templates for the contact hole layer application (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Ichimura, Koji; Hikichi, Ryugo; Harada, Saburo; Kanno, Koichi; Kurihara, Masaaki; Hayashi, Naoya

    2017-04-01

    Nanoimprint lithography, NIL, is gathering much attention as one of the most potential candidates for the next generation lithography for semiconductor. This technology needs no pattern data modification for exposure, simpler exposure system, and single step patterning process without any coat/develop truck, and has potential of cost effective patterning rather than very complex optical lithography and/or EUV lithography. NIL working templates are made by the replication of the EB written high quality master templates. Fabrication of high resolution master templates is one of the most important issues. Since NIL is 1:1 pattern transfer process, master templates have 4 times higher resolution compared with photomasks. Another key is to maintain the quality of the master templates in replication process. NIL process is applied for the template replication and this imprint process determines most of the performance of the replicated templates. Expectations to the NIL are not only high resolution line and spaces but also the contact hole layer application. Conventional ArF-i lithography has a certain limit in size and pitch for contact hole fabrication. On the other hand, NIL has good pattern fidelity for contact hole fabrication at smaller sizes and pitches compared with conventional optical lithography. Regarding the tone of the templates for contact hole, there are the possibilities of both tone, the hole template and the pillar template, depending on the processes of the wafer side. We have succeeded to fabricate both types of templates at 2xnm in size. In this presentation, we will be discussing fabrication or our replica template for the contact hole layer application. Both tone of the template fabrication will be presented as well as the performance of the replica templates. We will also discuss the resolution improvement of the hole master templates by using various e-beam exposure technologies.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hazelaar, Colien, E-mail: c.hazelaar@vumc.nl; Dahele, Max; Mostafavi, Hassan

    Purpose: Spine stereotactic body radiation therapy (SBRT) requires highly accurate positioning. We report our experience with markerless template matching and triangulation of kilovoltage images routinely acquired during spine SBRT, to determine spine position. Methods and Materials: Kilovoltage images, continuously acquired at 7, 11 or 15 frames/s during volumetric modulated spine SBRT of 18 patients, consisting of 93 fluoroscopy datasets (1 dataset/arc), were analyzed off-line. Four patients were immobilized in a head/neck mask, 14 had no immobilization. Two-dimensional (2D) templates were created for each gantry angle from planning computed tomography data and registered to prefiltered kilovoltage images to determine 2D shiftsmore » between actual and planned spine position. Registrations were considered valid if the normalized cross correlation score was ≥0.15. Multiple registrations were triangulated to determine 3D position. For each spine position dataset, average positional offset and standard deviation were calculated. To verify the accuracy and precision of the technique, mean positional offset and standard deviation for twenty stationary phantom datasets with different baseline shifts were measured. Results: For the phantom, average standard deviations were 0.18 mm for left-right (LR), 0.17 mm for superior-inferior (SI), and 0.23 mm for the anterior-posterior (AP) direction. Maximum difference in average detected and applied shift was 0.09 mm. For the 93 clinical datasets, the percentage of valid matched frames was, on average, 90.7% (range: 49.9-96.1%) per dataset. Average standard deviations for all datasets were 0.28, 0.19, and 0.28 mm for LR, SI, and AP, respectively. Spine position offsets were, on average, −0.05 (range: −1.58 to 2.18), −0.04 (range: −3.56 to 0.82), and −0.03 mm (range: −1.16 to 1.51), respectively. Average positional deviation was <1 mm in all directions in 92% of the arcs. Conclusions: Template matching and triangulation using kilovoltage images acquired during irradiation allows spine position detection with submillimeter accuracy at subsecond intervals. Although the majority of patients were not immobilized, most vertebrae were stable at the sub-mm level during spine SBRT delivery.« less

  14. Hemodynamic characterization of geometric cerebral aneurysm templates.

    PubMed

    Nair, Priya; Chong, Brian W; Indahlastari, Aprinda; Lindsay, James; DeJeu, David; Parthasarathy, Varsha; Ryan, Justin; Babiker, Haithem; Workman, Christopher; Gonzalez, L Fernando; Frakes, David

    2016-07-26

    Hemodynamics are currently considered to a lesser degree than geometry in clinical practices for evaluating cerebral aneurysm (CA) risk and planning CA treatment. This study establishes fundamental relationships between three clinically recognized CA geometric factors and four clinically relevant hemodynamic responses. The goal of the study is to develop a more combined geometric/hemodynamic basis for informing clinical decisions. Flows within eight idealized template geometries were simulated using computational fluid dynamics and measured using particle image velocimetry under both steady and pulsatile flow conditions. The geometric factor main effects were then analyzed to quantify contributions made by the geometric factors (aneurysmal dome size (DS), dome-to-neck ratio (DNR), and parent-vessel contact angle (PV-CA)) to effects on the hemodynamic responses (aneurysmal and neck-plane root-mean-square velocity magnitude (Vrms), aneurysmal wall shear stress (WSS), and cross-neck flow (CNF)). Two anatomical aneurysm models were also examined to investigate how well the idealized findings would translate to more realistic CA geometries. DNR made the greatest contributions to effects on hemodynamics including a 75.05% contribution to aneurysmal Vrms and greater than 35% contributions to all responses. DS made the next greatest contributions, including a 43.94% contribution to CNF and greater than 20% contributions to all responses. PV-CA and several factor interactions also made contributions of greater than 10%. The anatomical aneurysm models and the most similar idealized templates demonstrated consistent hemodynamic response patterns. This study demonstrates how individual geometric factors, and combinations thereof, influence CA hemodynamics. Bridging the gap between geometry and flow in this quantitative yet practical way may have potential to improve CA evaluation and treatment criteria. Agreement among results from idealized and anatomical models further supports the potential for a template-based approach to play a useful role in clinical practice. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. US Federal LCA Commons Life Cycle Inventory Unit Process Template

    EPA Science Inventory

    The US Federal LCA Commons Life Cycle Inventory Unit Process Template is a multi-sheet Excel template for life cycle inventory data, metadata and other documentation. The template comes as a package that consistent of three parts: (1) the main template itself for life cycle inven...

  16. Target templates: the precision of mental representations affects attentional guidance and decision-making in visual search.

    PubMed

    Hout, Michael C; Goldinger, Stephen D

    2015-01-01

    When people look for things in the environment, they use target templates-mental representations of the objects they are attempting to locate-to guide attention and to assess incoming visual input as potential targets. However, unlike laboratory participants, searchers in the real world rarely have perfect knowledge regarding the potential appearance of targets. In seven experiments, we examined how the precision of target templates affects the ability to conduct visual search. Specifically, we degraded template precision in two ways: 1) by contaminating searchers' templates with inaccurate features, and 2) by introducing extraneous features to the template that were unhelpful. We recorded eye movements to allow inferences regarding the relative extents to which attentional guidance and decision-making are hindered by template imprecision. Our findings support a dual-function theory of the target template and highlight the importance of examining template precision in visual search.

  17. Biometric templates selection and update using quality measures

    NASA Astrophysics Data System (ADS)

    Abboud, Ali J.; Jassim, Sabah A.

    2012-06-01

    To deal with severe variation in recording conditions, most biometric systems acquire multiple biometric samples, at the enrolment stage, for the same person and then extract their individual biometric feature vectors and store them in the gallery in the form of biometric template(s), labelled with the person's identity. The number of samples/templates and the choice of the most appropriate templates influence the performance of the system. The desired biometric template(s) selection technique must aim to control the run time and storage requirements while improving the recognition accuracy of the biometric system. This paper is devoted to elaborating on and discussing a new two stages approach for biometric templates selection and update. This approach uses a quality-based clustering, followed by a special criterion for the selection of an ultimate set of biometric templates from the various clusters. This approach is developed to select adaptively a specific number of templates for each individual. The number of biometric templates depends mainly on the performance of each individual (i.e. gallery size should be optimised to meet the needs of each target individual). These experiments have been conducted on two face image databases and their results will demonstrate the effectiveness of proposed quality-guided approach.

  18. Plans, preferences or going with the flow: An online exploration of women's views and experiences of birth plans.

    PubMed

    Divall, Bernie; Spiby, Helen; Nolan, Mary; Slade, Pauline

    2017-11-01

    To explore women's views of birth plans, and experiences of their completion and use. A qualitative, descriptive study, using Internet-mediated research methods. The discussion boards of two well-known, UK-based, online parenting forums, where a series of questions relating to birth plans were posted. Members of the selected parenting forums who had written and used, or who had chosen not to write or use, a birth plan. Women responded with a range of views and experiences relating to the completion and use of birth plans. The benefits of birth plans were described in terms of communication with healthcare professionals, potentially enhancing awareness of available options, and maintaining a sense of control during labour and birth. However, many respondents believed the idea of 'planning' birth was problematic, and described a reluctance to write a formal plan. The support of healthcare professionals, particularly midwives, was considered essential to the success of both writing and using birth plans. Our findings show a continued debate among women on the benefits and challenges involved in writing and using birth plans, suggesting problems for a 'one size fits all' approach often seen in the use of birth plan templates. In the context of maternity policy supporting women's choice and personalised care, and as a way of acknowledging perceived problems of 'planning' for birth, a flexible approach to birth plans is required, including the consideration of employing alternative nomenclature. Birth plans remain a point of contention in care contexts around the world. Midwives and other healthcare providers play a central role in supporting women to discuss available options, whether or not they decide to complete a formal birth plan. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Near-Native Protein Loop Sampling Using Nonparametric Density Estimation Accommodating Sparcity

    PubMed Central

    Day, Ryan; Lennox, Kristin P.; Sukhanov, Paul; Dahl, David B.; Vannucci, Marina; Tsai, Jerry

    2011-01-01

    Unlike the core structural elements of a protein like regular secondary structure, template based modeling (TBM) has difficulty with loop regions due to their variability in sequence and structure as well as the sparse sampling from a limited number of homologous templates. We present a novel, knowledge-based method for loop sampling that leverages homologous torsion angle information to estimate a continuous joint backbone dihedral angle density at each loop position. The φ,ψ distributions are estimated via a Dirichlet process mixture of hidden Markov models (DPM-HMM). Models are quickly generated based on samples from these distributions and were enriched using an end-to-end distance filter. The performance of the DPM-HMM method was evaluated against a diverse test set in a leave-one-out approach. Candidates as low as 0.45 Å RMSD and with a worst case of 3.66 Å were produced. For the canonical loops like the immunoglobulin complementarity-determining regions (mean RMSD <2.0 Å), the DPM-HMM method performs as well or better than the best templates, demonstrating that our automated method recaptures these canonical loops without inclusion of any IgG specific terms or manual intervention. In cases with poor or few good templates (mean RMSD >7.0 Å), this sampling method produces a population of loop structures to around 3.66 Å for loops up to 17 residues. In a direct test of sampling to the Loopy algorithm, our method demonstrates the ability to sample nearer native structures for both the canonical CDRH1 and non-canonical CDRH3 loops. Lastly, in the realistic test conditions of the CASP9 experiment, successful application of DPM-HMM for 90 loops from 45 TBM targets shows the general applicability of our sampling method in loop modeling problem. These results demonstrate that our DPM-HMM produces an advantage by consistently sampling near native loop structure. The software used in this analysis is available for download at http://www.stat.tamu.edu/~dahl/software/cortorgles/. PMID:22028638

  20. Preparation of Ice-Templated MOF-Polymer Composite Monoliths and Their Application for Wastewater Treatment with High Capacity and Easy Recycling.

    PubMed

    Fu, Qingshan; Wen, Lang; Zhang, Lei; Chen, Xuedan; Pun, Daniel; Ahmed, Adham; Yang, Yonghong; Zhang, Haifei

    2017-10-04

    An ice-templating process was used to fabricate polymer/MOF monoliths, specifically chitosan/UiO-66, as adsorbents for water treatment. The ice-templated macropores enhanced mass transport, while the monoliths could be easily recovered from solution. This was demonstrated by the adsorption of methylchlorophenoxypropionic acid (MCPP, a herbicide compound) from dilute aqueous solution. To enhance the stability, the freeze-dried monoliths were treated with NaOH solution, solvent exchanged, and dried. The treated chitosan/UiO-66 monolith achieved an adsorption capacity of 34.33 mg g -1 (a maximum theoretic value of 334 mg g -1 by the Langmuir model), closer to the capacity (36.00 mg g -1 ) of the freshly prepared UiO-66 nanoparticles and much higher than that of the NaOH-washed UiO-66 nanoparticles (18.55 mg g -1 ), by performing the tests in 60 ppm MCPP solution. The composite monolith could be easily picked up using tweezers and used for recycling tests. Over 80% of the adsorption capacity was retained after three more cycles. The powder X-ray diffraction and N 2 sorption studies suggested the crystalline structure of UiO-66 was destroyed during NaOH washing procedure. This, however, provides the potential to improve the adsorption capacity by developing methods to fabricate true polymer/MOF composites.

Top