A reliability analysis of the revised competitiveness index.
Harris, Paul B; Houston, John M
2010-06-01
This study examined the reliability of the Revised Competitiveness Index by investigating the test-retest reliability, interitem reliability, and factor structure of the measure based on a sample of 280 undergraduates (200 women, 80 men) ranging in age from 18 to 28 years (M = 20.1, SD = 2.1). The findings indicate that the Revised Competitiveness Index has high test-retest reliability, high inter-item reliability, and a stable factor structure. The results support the assertion that the Revised Competitiveness Index assesses competitiveness as a stable trait rather than a dynamic state.
NASA Technical Reports Server (NTRS)
Lauenstein, Jean-Marie
2015-01-01
The JEDEC JESD57 test standard, Procedures for the Measurement of Single-Event Effects in Semiconductor Devices from Heavy-Ion Irradiation, is undergoing its first revision since 1996. In this talk, we place this test standard into context with other relevant radiation test standards to show its importance for single-event effect radiation testing for space applications. We show the range of industry, government, and end-user party involvement in the revision. Finally, we highlight some of the key changes being made and discuss the trade-space in which setting standards must be made to be both useful and broadly adopted.
Cherner, M; Suarez, P; Lazzaretto, D; Fortuny, L Artiola I; Mindt, Monica Rivera; Dawes, S; Marcotte, Thomas; Grant, I; Heaton, R
2007-03-01
The large number of primary Spanish speakers both in the United States and the world makes it imperative that appropriate neuropsychological assessment instruments be available to serve the needs of these populations. In this article we describe the norming process for Spanish speakers from the U.S.-Mexico border region on the Brief Visuospatial Memory Test-revised and the Hopkins Verbal Learning Test-revised. We computed the rates of impairment that would be obtained by applying the original published norms for these tests to raw scores from the normative sample, and found substantial overestimates compared to expected rates. As expected, these overestimates were most salient at the lowest levels of education, given the under-representation of poorly educated subjects in the original normative samples. Results suggest that demographically corrected norms derived from healthy Spanish-speaking adults with a broad range of education, are less likely to result in diagnostic errors. At minimum, demographic corrections for the tests in question should include the influence of literacy or education, in addition to the traditional adjustments for age. Because the age range of our sample was limited, the norms presented should not be applied to elderly populations.
DOT National Transportation Integrated Search
2017-04-28
The document describes the overall process for evaluating Dedicated Short Range Communication (DSRC) Roadside Units (RSU) against USDOT RSU Specification 4.1 in preparation for field evaluation. The Test Cases contained in this document only evaluate...
Detailed analysis of the Japanese version of the Rapid Dementia Screening Test, revised version.
Moriyama, Yasushi; Yoshino, Aihide; Muramatsu, Taro; Mimura, Masaru
2017-11-01
The number-transcoding task on the Japanese version of the Rapid Dementia Screening Test (RDST-J) requires mutual conversion between Arabic and Chinese numerals (209 to , 4054 to , to 681, to 2027). In this task, question and answer styles of Chinese numerals are written horizontally. We investigated the impact of changing the task so that Chinese numerals are written vertically. Subjects were 211 patients with very mild to severe Alzheimer's disease and 42 normal controls. Mini-Mental State Examination scores ranged from 26 to 12, and Clinical Dementia Rating scores ranged from 0.5 to 3. Scores of all four subtasks of the transcoding task significantly improved in the revised version compared with the original version. The sensitivity and specificity of total scores ≥9 on the RDST-J original and revised versions for discriminating between controls and subjects with Clinical Dementia Rating scores of 0.5 were 63.8% and 76.6% on the original and 60.1% and 85.8% on revised version. The revised RDST-J total score had low sensitivity and high specificity compared with the original RDST-J for discriminating subjects with Clinical Dementia Rating scores of 0.5 from controls. © 2017 Japanese Psychogeriatric Society.
Test Area C-64 Range Environmental Assessment, Revision 1
2010-10-01
DOI U.S. Department of the Interior DNL Day–Night Average Sound Level DU Depleted Uranium EBD Environmental Baseline Document EIAP Environmental...vulnerability, burning sensitivity, drop tests, bullet impact tests, sympathetic detonation tests, advanced warhead design tests, and depleted uranium (DU...land back to range use. Source: U.S. Air Force, 2009 DU = depleted uranium ; ERP = Environmental Restoration Program; LUC = land use control; RW
Crogan, Neva L; Evans, Bronwynne C
2006-11-01
Lack of nursing home resident satisfaction with meals often results in reduced food intake, leading to poor nutritional status, weight loss, functional decline, and depression. The purpose of this article is to describe the development and initial testing of the 28-item revised Food Expectations-Long-Term Care (FoodEx-LTC) questionnaire with a convenience sample of nursing home residents (N = 61). Because of possible respondent burden, the original 44-item, five-domain FoodEx-LTC was revised, resulting in the deletion of 16 redundant items and those with inter-item correlations less than .25. Coefficient alpha scores ranged from .65 to .82, and test-retest correlations ranged from .79 to .88, dependent on domain. This revised instrument has good initial validity and reliability, resulting in a shorter instrument that accurately assesses nursing home resident satisfaction with food and food service.
Santa Rosa Island Final Range Environmental Assessment, Revision 1. Eglin Air Force Base, Florida
2012-03-01
contours would be temporary. LCAC crossings would occur only at designated areas. Surf zone tests involving live detonations will require a separate...would conduct LCAC live fire testing only under conditions of suitable visibility and sea state of 3 or less. • Pre- and post -detonation monitoring...Red-cockaded Woodpecker RDT&E Research , Development, Test , and Evaluation REA Range Environmental Assessment ROI Region of Influence RUR Range
Moore, Amy Lawson; Miller, Terissa M
2018-01-01
The purpose of the current study is to evaluate the validity and reliability of the revised Gibson Test of Cognitive Skills, a computer-based battery of tests measuring short-term memory, long-term memory, processing speed, logic and reasoning, visual processing, as well as auditory processing and word attack skills. This study included 2,737 participants aged 5-85 years. A series of studies was conducted to examine the validity and reliability using the test performance of the entire norming group and several subgroups. The evaluation of the technical properties of the test battery included content validation by subject matter experts, item analysis and coefficient alpha, test-retest reliability, split-half reliability, and analysis of concurrent validity with the Woodcock Johnson III Tests of Cognitive Abilities and Tests of Achievement. Results indicated strong sources of evidence of validity and reliability for the test, including internal consistency reliability coefficients ranging from 0.87 to 0.98, test-retest reliability coefficients ranging from 0.69 to 0.91, split-half reliability coefficients ranging from 0.87 to 0.91, and concurrent validity coefficients ranging from 0.53 to 0.93. The Gibson Test of Cognitive Skills-2 is a reliable and valid tool for assessing cognition in the general population across the lifespan.
Muneta, Takeshi; Hara, Kenji; Ju, Young-Jin; Mochizuki, Tomoyuki; Morito, Toshiyuki; Yagishita, Kazuyoshi; Sekiya, Ichiro
2010-06-01
The purpose of the study was to compare the outcome of revision anterior cruciate ligament (ACL) reconstruction by the double-bundle (DB) technique using multi-strand semitendinosus tendon with that of primary reconstruction by use of the same technique. The study included 21 patients who underwent revision ACL reconstruction (mean follow-up, 40 months) with the semitendinosus tendon DB technique between 1995 and 2006 and 86 unilateral primary DB ACL reconstructions (mean follow-up, 33 months) between 2000 and 2004. The outcome of both groups was compared based on differences between operated and unoperated limbs and modified International Knee Documentation Committee grades. Both the overall and sports-related subjective scores were evaluated between the 2 groups. The KT measurements (MEDmetric, San Diego, CA) averaged 1.7 mm (SD, 1.8 mm) in the revision group and 1.5 mm (SD, 1.6 mm) in the primary group. There was no significant difference in KT measurements between the 2 groups. The Lachman test was negative in 83% of revision cases and 87% of primary cases; the anterior drawer test was negative in 83% and 91%, respectively, and the pivot-shift test was negative in 78% and 90%, respectively. There was a tendency for a positive pivot-shift test in the revision group being higher. The Lysholm score and subjective recovery score were significantly lower in the revision group. The semitendinosus tendon DB revision procedure provided range of motion and anterior stability comparable to those after primary DB surgery and a comparable return to athletic activities. However, the patients tended to have positive pivot-shift test results. The revision cases were also inferior in terms of the general evaluation of recovery of knee condition. The outcome scores were lower overall in the revision group. Level IV, therapeutic case series. Copyright (c) 2010 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
A test of Hartnett's revisions to the pubic symphysis and fourth rib methods on a modern sample.
Merritt, Catherine E
2014-05-01
Estimating age at death is one of the most important aspects of creating a biological profile. Most adult age estimation methods were developed on North American skeletal collections from the early to mid-20th century, and their applicability to modern populations has been questioned. In 2010, Hartnett used a modern skeletal collection from the Maricopia County Forensic Science Centre to revise the Suchey-Brooks pubic symphysis method and the İşcan et al. fourth rib methods. The current study tests Hartnett's revised methods as well as the original Suchey-Brooks and İşcan et al. methods on a modern sample from the William Bass Skeletal Collection (N = 313, mean age = 58.5, range 19-92). Results show that the Suchey-Brooks and İşcan et al. methods assign individuals to the correct phase 70.8% and 57.5% of the time compared with Hartnett's revised methods at 58.1% and 29.7%, respectively, with correctness scores based on one standard deviation of the mean rather than the entire age range. Accuracy and bias scores are significantly improved for Hartnett's revised pubic symphysis method and marginally better for Hartnett's revised fourth rib method, suggesting that the revised mean ages at death of Hartnett's phases better reflect this modern population. Overall, both Hartnett's revised methods are reliable age estimation methods. For the pubic symphysis, there are significant improvements in accuracy and bias scores, especially for older individuals; however, for the fourth rib, the results are comparable to the original İşcan et al. methods, with some improvement for older individuals. © 2014 American Academy of Forensic Sciences.
[Goodbye to half of tomorrow's physicians].
Burcharth, Jakob; Burgdorf, Stefan; Rosenberg, Jacob
2009-12-14
Danish citizenship can only be obtained by passing a citizenship test. The test was introduced in December 2005 which made it more difficult to obtain Danish citizenship, and revised in 2008 which made the process even harder. We present a study which tests how many Danish and Swedish medical students enrolled at the University of Copenhagen would be able to obtain a Danish citizenship. The test comprised 40 questions regarding Danish democracy, history and politics. The questions were taken from the Ministry of Refugee and Immigration's pool of questions. Medical students at the University of Copenhagen were invited to participate in the study. Participation was voluntary. The tests were revised blinded and anonymously. The results were analyzed using Fisher's exact test and Mann-Whitney U-test. We enrolled 202 medical students (139 women and 63 men). Among these participants, 168 were Danish and 34 Swedish medical students studying in Copenhagen. A total of 49% of the students passed the test. 58% of the Danish students and 6% of the Swedish students passed the test (p < 0.001). The Danish students had a median of eight errors (range: 1-18) and Swedish students had a median of 15 errors (range: 5-25) (p < 0.001). We suggest an export agreement with countries like Poland and India comprising the 51% students who failed the citizenship test as part of a package solution, where Denmark in return receives competent physicians of said nationalities. We also suggest that the contents of the test for citizenship be revised to achieve a better assessment of the applicant's ability to integrate in the Danish society.
Test Areas B-71 and B-82 Range Environmental Assessment, Revision 1
2010-10-01
floridanus Blackberry Rubus cuneifolius Pocket Gopher Geomys pinetus Sand Pine Pinus Clausa White-tailed Deer Castor canadensis Pine-woods Bluestem...tortoise is found primarily within the Sandhills and open grassland ecological associations on the Eglin Range, where it excavates a tunnel -like
Factor Structure of Psychoeducational and Neuropsychological Measures of Learning-Disabled Children.
ERIC Educational Resources Information Center
Chittooran, Mary Mathai; And Others
1993-01-01
Administered Wechsler Intelligence Scale for Children-Revised, Halstead-Reitan Neuropsychological Battery, Peabody Picture Vocabulary Test, and Wide Range Achievement Test to 934 learning-disabled students between ages 8 and 16. Principal-components analysis with varimax rotation indicated existence of seven factors: Verbal Reasoning, Academic…
A Goniometry Paradigm Shift to Measure Burn Scar Contracture in Burn Patients
2017-10-01
test more extensively a recently designed Revised Goniometry (RG) method and compare it to Standard Goniometry (SG)used to measure burn scar...joint angle measurements willbe found between SG techniques compared to RG techniques which incorporate CKM and CFU principles. Specific Aim 1: To... compare the average reduction in joint range of motion measured with the standard GM measurements to a newly conceived set of revised GM measurements in
Code of Federal Regulations, 2013 CFR
2013-04-01
..., body weight range, sex, source of supply, species, strain, substrain, and age of the test system. (5... methods to be used. (b) All changes in or revisions of an approved protocol and the reasons therefore...
Code of Federal Regulations, 2011 CFR
2011-04-01
..., body weight range, sex, source of supply, species, strain, substrain, and age of the test system. (5... methods to be used. (b) All changes in or revisions of an approved protocol and the reasons therefore...
Code of Federal Regulations, 2012 CFR
2012-04-01
..., body weight range, sex, source of supply, species, strain, substrain, and age of the test system. (5... methods to be used. (b) All changes in or revisions of an approved protocol and the reasons therefore...
Test Scatter on the WISC-R in Learning Disabled Children.
ERIC Educational Resources Information Center
Tabachnick, Barbara Gerson
Scatter on the revised Wechsler Intelligence Scale for children (WISC-R) was evaluated for 105 learning disabled (LD) children. Scatter was defined as range of scaled scores on: (1) five regular verbal tests; (2) five regular performance tests; and (3) all 10 regular subtests. Pairwise combinations of 11 subtests were also evaluated for deviations…
Characteristics of Third-Grade Learning Disabled Children.
ERIC Educational Resources Information Center
Cullen, Joy L.; And Others
1981-01-01
The Developmental Test of Visual-Motor Integration, the Wide Range Achievement Test, and the Student's Perception of Ability Scale were administreed to 70 learning disabled and 73 normally achieving third-grade children who had been stratified on full scale Wechsler Intelligence Scale for Children-Revised (WISC-R) IQ scores. (Author)
Children with Spina Bifida: Why Do They Fail in School?
ERIC Educational Resources Information Center
Eisert, Debra C.; Shelburne, Kathryn
Thirty-eight children with spina bifida, a congenital defect involving the nervous system, were tested for verbal and performance ability and freedom from distractibility on the Wechsler Intelligence Scale for Children-Revised. Achievement on the Wide Range Achievement Test was also measured, and medical and socioeconomic information obtained.…
Code of Federal Regulations, 2010 CFR
2010-07-01
... Measurements Required, and Maximum Discrepancy Specification C Table C-1 to Subpart C of Part 53 Protection of... Reference Methods Pt. 53, Subpt. C, Table C-1 Table C-1 to Subpart C of Part 53—Test Concentration Ranges..., June 22, 2010, table C-1 to subpart C was revised, effective Aug. 23, 2010. For the convenience of the...
Revision total knee arthroplasty for septic versus aseptic failure.
Rajgopal, Ashok; Vasdev, Attique; Gupta, Himanshu; Dahiya, Vivek
2013-12-01
To compare the medium-term outcome of revision total knee arthroplasty (TKA) for septic versus aseptic failure. Records of 142 patients who underwent revision TKA by a single senior surgeon for septic (n=65) or aseptic (n=77) failure were reviewed. In the septic group, 67 knees in 42 women and 23 men were included. In the aseptic group, 88 knees in 51 women and 26 men were included. The Knee Society Score was measured. The Kaplan Meier survival curve at months 36, 60, and 95 was plotted, with revision as the end point. The survival rates at each specific time point between the 2 groups were compared using the Z test. The Knee Society Scores improved 18% from 51 to 69 in the septic group and 18% from 52 to 70 in the aseptic group (p=0.72). The range of motion improved 30% from 72 to 102 degrees in the septic group and 39% from 62 to 100 degrees in the aseptic group (p<0.001). Results of the 2 groups were similar in terms of the Knee Society Score, range of motion, and the Kaplan-Meier survivorship.
Working Memory and the Revision of Syntactic and Discourse Ambiguities
Evans, William S.; Caplan, David; Ostrowski, Adam; Michaud, Jennifer; Guarino, Anthony; Waters, Gloria
2015-01-01
Two hundred participants, 50 in each of four age ranges (19 – 29; 30 – 49, 50 – 69, 70 – 90) were tested for short term working memory, speed of processing and on-line processing of three types of sentences in which an initially assigned syntactic structure and/or semantic interpretation had to be revised. Self-paced reading times were longer for the segments which signaled the need for revision, and there were interactions of age and sentence type and of speed of processing and sentence type, but not of working memory and sentence type, on reading times for these segments. The results provide evidence that working memory does not support the processes that revise the structure and interpretation of sentences and discourse. PMID:25485458
Inter and intra-system size variability of reverse shoulder arthroplasty polyethylene inserts
Teeter, Matthew G.; Dawson, Matthew T.; Athwal, George S.
2016-01-01
Background: As the incidence of reverse shoulder arthroplasty (RSA) increases, so will the revision burden. At times, the revision surgeon may be faced with a well-fixed component on one side of the joint and revision implants from a different manufacturer. The ability to use glenoid and humeral implants from different manufacturers could simplify the revision procedure. This study hypothesized that across a range of RSA systems, some implants would demonstrate high size compatibility and others would demonstrate low compatibility. Materials and Methods: Six polyethylene inserts each from eight reverse total shoulder arthroplasty systems were examined (48 total inserts). All inserts were scanned using a laboratory micro-computed tomography scanner at 50 μm isotropic voxel spacing, and their surface geometries were reconstructed. The different implant geometries were co-registered, and the three-dimensional (3D) variability between the articular surfaces of the different implant systems was measured. Intrasystem manufacturing variability was also determined by measuring the 3D variability of inserts from the same system. Results: The intersystem polyethylene articular surface deviations between same-size systems were not significantly different (P = 0.61) and were a mean maximum of 60 ± 16 μm (range: 30-80 μm). Intrasystem manufacturing variability was equivalent between all but two models, averaging 49 ± 17 μm (range: 23-99 μm). Discussion: Differences in articular geometry between same-size inserts from different systems were on the same scale as intrasystem manufacturing variability, suggesting that different implant systems of the same nominal diameter could potentially be used interchangeably in revision or extenuating circumstances. Conclusion: The results of this study suggest that surgeons can theoretically interchange same-sized implant components from the different RSA systems tested when conducting revisions. PMID:26980984
Structural Validity of the Movement ABC-2 Test: Factor Structure Comparisons across Three Age Groups
ERIC Educational Resources Information Center
Schulz, Joerg; Henderson, Sheila E.; Sugden, David A.; Barnett, Anna L.
2011-01-01
Background: The Movement ABC test is one of the most widely used assessments in the field of Developmental Coordination Disorder (DCD). Improvements to the 2nd edition of the test (M-ABC-2) include an extension of the age range and reduction in the number of age bands as well as revision of tasks. The total test score provides a measure of motor…
Merolla, Giovanni; Wagner, Eric; Sperling, John W; Paladini, Paolo; Fabbri, Elisabetta; Porcellini, Giuseppe
2018-01-01
There remains a paucity of studies examining the conversion of failed hemiarthroplasty (HA) to reverse total shoulder arthroplasty (RTSA). Therefore, the purpose of this study was to examine a large series of revision HA to RTSA. A population of 157 patients who underwent conversion of a failed HA to a revision RTSA from 2006 through 2014 were included. The mean follow-up was 49 months (range, 24-121 months). The indications for revision surgery included instability with rotator cuff insufficiency (n = 127) and glenoid wear (n = 30); instability and glenoid wear were associated in 38 cases. Eight patients with infection underwent 2-stage reimplantation. Patients experienced significant improvements in their preoperative to postoperative pain and shoulder range of motion (P < .0001), with median American Shoulder and Elbow Surgeons and Simple Shoulder Test scores of 60 and 6 points, respectively. There were 11 (7%) repeated revision surgeries, secondary to glenoid component loosening (n = 3), instability (n = 3), humeral component disassembly (n = 2), humeral stem loosening (n = 1), and infection (n = 2). Implant survivorship was 95.5% at 2 years and 93.3% at 5 years. There were 4 reoperations including axillary nerve neurolysis (n = 2), heterotopic ossification removal (n = 1), and hardware removal for rupture of the metal cerclage for an acromial fracture (n = 1). At final follow-up, there were 5 "at-risk" glenoid components. Patients experience satisfactory pain relief and recovery of reasonable shoulder function after revision RTSA from a failed HA. There was a relatively low revision rate, with glenoid loosening and instability being the most common causes. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Fox, Jeff A; Pierce, Mark; Bojchuk, John; Hayden, Jennifer; Bush-Joseph, Charles A; Bach, Bernard R
2004-10-01
To evaluate the effectiveness of a revision anterior cruciate ligament reconstruction with nonirradiated patellar tendon allograft used to salvage a failed index patellar tendon autograft procedure. Retrospective case series with minimum 2-year follow-up. Between 1993 and 1999, 39 patients underwent a revision reconstruction. Clinical, radiographic, arthrometric, and functional evaluations were performed. The Tegner, Lysholm, Noyes, Knee Injury and Osteoarthritis Outcome Score (KOOS), International Knee Documentation Committee (IKDC), and SF-12 rating scales were used. Statistical analysis was conducted with our Biostatistics Department. Thirty-two of 38 patients (84%) were personally evaluated. The mean patient age was 28 years (range, 16 to 57 years); the mean follow-up was 4.8 years (range, 2.1 to 12.1 years). After revision, there were significant improvements in the Lachman and pivot-shift test results: 87% had a grade 0/1+ Lachman and a 0/1+ pivot-shift. However, 25% had a grade 1+ pivot-shift. Postoperatively, KT-1000 testing revealed that 84% had a maximum manual side-to-side difference of < or =3 mm and 6% had >5 mm. Functional testing revealed a mean 4% difference in side-to-side comparisons for a single-leg hop for distance and time, as well as vertical jump. The mean results of Noyes sports function (72), Lysholm (75), Tegner (6.3), KOOS sports activity scale (67), SF-12 physical component (48), SF-12 mental component (55), and IKDC (71) were obtained. The Noyes sports activity score showed a significant improvement from 55 preoperatively to 70 at follow-up. Subjectively, 87% of patients indicated that they were completely or mostly satisfied with the surgical outcome. One patient required another revision. The 2- to 11-year follow-up showed that the results of revision ACL reconstruction with a nonirradiated patellar tendon allograft were less favorable than those of a primary anterior cruciate ligament reconstruction, with a lower subjective satisfaction level and a higher percentage of patients with grade 1+ or higher pivot-shift results. However, when compared with previously published reports, our results were comparable and underscore that revision anterior cruciate ligament surgery should be approached with tempered enthusiasm and careful preoperative counseling, and considered as a salvage procedure. Level IV.
ERIC Educational Resources Information Center
Goldberg, Gail Lynn; Roswell, Barbara Sherr; Michaels, Hillary
1996-01-01
Student engagement during testing in the full range of writing process activities they had been taught was studied. Results with 28 third-grade draft sets, 21 fifth-grade sets, and 38 eighth-grade sets on the Maryland School Performance Assessment writing test show that students' peer responses are unengaged, minimal, and formulaic, and that their…
Results of revision anterior shoulder stabilization surgery in adolescent athletes.
Blackman, Andrew J; Krych, Aaron J; Kuzma, Scott A; Chow, Roxanne M; Camp, Christopher; Dahm, Diane L
2014-11-01
The purpose of this study was to determine failure rates, functional outcomes, and risk factors for failure after revision anterior shoulder stabilization surgery in high-risk adolescent athletes. Adolescent athletes who underwent primary anterior shoulder stabilization were reviewed. Patients undergoing subsequent revision stabilization surgery were identified and analyzed. Failure rates after revision surgery were assessed by Kaplan-Meier analysis. Failure was defined as recurrent instability requiring reoperation. Functional outcomes included the Marx activity score; American Shoulder and Elbow Surgeons score; and University of California, Los Angeles score. The characteristics of patients who required reoperation for recurrent instability after revision surgery were compared with those of patients who required only a single revision to identify potential risk factors for failure. Of 90 patients who underwent primary anterior stabilization surgery, 15 (17%) had failure and underwent revision surgery (mean age, 16.6 years; age range, 14 to 18 years). The mean follow-up period was 5.5 years (range, 2 to 12 years). Of the 15 revision patients, 5 (33%) had recurrent dislocations and required repeat revision stabilization surgery at a mean of 50 months (range, 22 to 102 months) after initial revision. No risk factors for failure were identified. The Kaplan-Meier reoperation-free estimates were 86% (95% confidence interval, 67% to 100%) at 24 months and 78% (95% confidence interval, 56% to 100%) at 48 months after revision surgery. The mean final Marx activity score was 14.8 (range, 5 to 20); American Shoulder and Elbow Surgeons score, 82.1 (range, 33 to 100); and University of California, Los Angeles score, 30.8 (range, 16 to 35). At 5.5 years' follow-up, adolescent athletes had a high failure rate of revision stabilization surgery and modest functional outcomes. We were unable to convincingly identify specific risk factors for failure of revision surgery. Level IV, retrospective therapeutic case series. Copyright © 2014 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
An improved snow scheme for the ECMWF land surface model: Description and offline validation
Emanuel Dutra; Gianpaolo Balsamo; Pedro Viterbo; Pedro M. A. Miranda; Anton Beljaars; Christoph Schar; Kelly Elder
2010-01-01
A new snow scheme for the European Centre for Medium-Range Weather Forecasts (ECMWF) land surface model has been tested and validated. The scheme includes a new parameterization of snow density, incorporating a liquid water reservoir, and revised formulations for the subgrid snow cover fraction and snow albedo. Offline validation (covering a wide range of spatial and...
Rengier, Fabian; Rauch, Philipp Julian; Partovi, Sasan; Kirsch, Joachim; Nawrotzki, Ralph
2010-12-20
this study examines whether peer-teaching, in the setting of a three-day revision course in anatomy, is effective in preparing medical students for their national anatomy exam. the anatomy course was designed for candidates taking the first part of the German national medical exam. Increase of knowledge during the course was assessed by tests before and after the course (group A). To test equivalence, two control groups participated in the pre-test (group B) or in the course and in the post-test (group C). Participants anonymously rated 14 feedback items on a five-point Likert scale ranging from 1 (full agreement) to 5 (full disagreement). group A students' performance improved significantly during the course with a mean increase of 7.15 points (11.9% improvement; p<0.001). Equivalence testing showed that performance of group A students in the pre-/post-tests was equal to those of group B pre-tests and group C post-tests, respectively. Agreement on the 14 feedback items was highly significant (p<0.001 for all items), with a global median of 1. this study shows that a three-day anatomy revision course is effective and highly appreciated by medical students in their preparation for the national exam. Moreover, peer-teaching is reliable at this stage of the medical curriculum. 2010 Elsevier GmbH. All rights reserved.
Code of Federal Regulations, 2012 CFR
2012-07-01
... the SIM mode at a scan rate of 1.5 scans/second to maximize the linear quantitative range and... Research Group, Texas A&M University, 833 Graham Rd., College Station, TX, 77845, (409) 690-0095. 8... following information is contained in the detailed quantitative reports: average RRF derived from the...
Test Area B-70 Final Range Environmental Assessment, Revision 1
2009-06-01
the Sandhills and Open Grassland ecological associations on the Eglin Range, where it excavates a tunnel -like burrow for shelter from climatic extremes...Sciurus niger Gallberry Ilex glabra Least Shrew Cryptotis parva Gopher Apple Licania michauxii Cottontail Rabbit Sylvilagus floridanus Sand Blackberry ...within the Sandhills and Open Grassland ecological associations on Eglin, where it excavates a tunnel - like burrow for shelter from climatic extremes and
DOT National Transportation Integrated Search
2012-12-01
The design and selection of surface treatment binders in service is currently based on specifications that include tests of emulsion residues or hot-applied asphalt cements at standard temperatures that do not cover the entire range of in service tem...
Effects of body mass index and education on verbal and nonverbal memory.
De Wit, Liselotte; Kirton, Joshua W; O'Shea, Deirdre M; Szymkowicz, Sarah M; McLaren, Molly E; Dotson, Vonetta M
2017-05-01
We previously reported that higher education protects against executive dysfunction related to higher body mass index (BMI) in younger, but not older, adults. We now extend the previous analyses to verbal and nonverbal memory. Fifty-nine healthy, dementia-free community-dwelling adults ranging in age from 18 to 81 years completed the Hopkins Verbal Learning Test - Revised (HVLT-R) and the Brief Visuospatial Memory Test - Revised (BVMT-R). Self-reported years of education served as a proxy for cognitive reserve. We found that more highly educated individuals maintained their BVMT-R immediate recall performance across the range of BMI, but in less educated individuals, higher BMI was associated with worse performance. Our findings suggest that education may play a protective role against BMI-related nonverbal learning deficits, similar to previous reports for verbal memory and executive functioning. Results highlight the importance of considering educational background when determining the risk for BMI-related cognitive impairment in clinical settings.
Evola, Francesco Roberto; Costarella, Luciano; Evola, Giuseppe; Barchitta, Martina; Agodi, Antonella; Sessa, Giuseppe
2017-01-01
AIM To evaluate the clinical and X-ray results of acetabular components and tantalum augments in prosthetic hip revisions. METHODS Fifty-eight hip prostheses with primary failure of the acetabular component were reviewed with tantalum implants. The clinical records and X-rays of these cases were retrospectively reviewed. Bone defect evaluations were based on preoperative CT scans and classified according to Paprosky criteria of Radiolucent lines and periprosthetic gaps; implant mobilization and osteolysis were evaluated by X-ray. An ad hoc database was created and statistical analyses were performed with SPSS software (IBM SPSS Statistics for Windows, version 23.0). Statistical analyses were carried out using the Student’s t test for independent and paired samples. A P value of < 0.05 was considered statistically significant and cumulative survival was calculated by the Kaplan-Meier method. RESULTS The mean follow-up was 87.6 ± 25.6 mo (range 3-120 mo). 25 cases (43.1%) were classified as minor defects, and 33 cases (56.9%) as major defects. The preoperative HHS rating improved significantly from a mean of 40.7 ± 6.1 (range: 29-53) before revision, to a mean of 85.8 ± 6.1 (range: 70-94) at the end of the follow-up (Student’s t test for paired samples: P < 0.001). Considering HHS only at the end of follow-up, no statistically significant difference was observed between patients with a major or minor defect (Student’s t test for independent samples: P > 0.05). Radiolucent lines were found in 4 implants (6.9%). Postoperative acetabular gaps were observed in 5 hips (8.6%). No signs of implant mobilization or areas of periprosthetic osteolysis were found in the x-rays at the final follow-up. Only 3 implants failed: 1 case of infection and 2 cases of instability. Defined as the end-point, cumulative survival at 10 years was 95% (for all reasons) and 100% for aseptic loosening of the acetabular component. CONCLUSION The medium-term use of prosthetic tantalum components in prosthetic hip revisions is safe and effective in a wide variety of acetabular bone defects. PMID:28808626
Evola, Francesco Roberto; Costarella, Luciano; Evola, Giuseppe; Barchitta, Martina; Agodi, Antonella; Sessa, Giuseppe
2017-07-18
To evaluate the clinical and X-ray results of acetabular components and tantalum augments in prosthetic hip revisions. Fifty-eight hip prostheses with primary failure of the acetabular component were reviewed with tantalum implants. The clinical records and X-rays of these cases were retrospectively reviewed. Bone defect evaluations were based on preoperative CT scans and classified according to Paprosky criteria of Radiolucent lines and periprosthetic gaps; implant mobilization and osteolysis were evaluated by X-ray. An ad hoc database was created and statistical analyses were performed with SPSS software (IBM SPSS Statistics for Windows, version 23.0). Statistical analyses were carried out using the Student's t test for independent and paired samples. A P value of < 0.05 was considered statistically significant and cumulative survival was calculated by the Kaplan-Meier method. The mean follow-up was 87.6 ± 25.6 mo (range 3-120 mo). 25 cases (43.1%) were classified as minor defects, and 33 cases (56.9%) as major defects. The preoperative HHS rating improved significantly from a mean of 40.7 ± 6.1 (range: 29-53) before revision, to a mean of 85.8 ± 6.1 (range: 70-94) at the end of the follow-up (Student's t test for paired samples: P < 0.001). Considering HHS only at the end of follow-up, no statistically significant difference was observed between patients with a major or minor defect (Student's t test for independent samples: P > 0.05). Radiolucent lines were found in 4 implants (6.9%). Postoperative acetabular gaps were observed in 5 hips (8.6%). No signs of implant mobilization or areas of periprosthetic osteolysis were found in the x-rays at the final follow-up. Only 3 implants failed: 1 case of infection and 2 cases of instability. Defined as the end-point, cumulative survival at 10 years was 95% (for all reasons) and 100% for aseptic loosening of the acetabular component. The medium-term use of prosthetic tantalum components in prosthetic hip revisions is safe and effective in a wide variety of acetabular bone defects.
Comparative durability and costs analysis of ventricular shunts.
Agarwal, Nitin; Kashkoush, Ahmed; McDowell, Michael M; Lariviere, William R; Ismail, Naveed; Friedlander, Robert M
2018-05-11
OBJECTIVE Ventricular shunt (VS) durability has been well studied in the pediatric population and in patients with normal pressure hydrocephalus; however, further evaluation in a more heterogeneous adult population is needed. This study aims to evaluate the effect of diagnosis and valve type-fixed versus programmable-on shunt durability and cost for placement of shunts in adult patients. METHODS The authors retrospectively reviewed the medical records of all patients who underwent implantation of a VS for hydrocephalus at their institution over a 3-year period between August 2013 and October 2016 with a minimum postoperative follow-up of 6 months. The primary outcome was shunt revision, which was defined as reoperation for any indication after the initial procedure. Supply costs, shunt durability, and hydrocephalus etiologies were compared between fixed and programmable valves. RESULTS A total of 417 patients underwent shunt placement during the index time frame, consisting of 62 fixed shunts (15%) and 355 programmable shunts (85%). The mean follow-up was 30 ± 12 (SD) months. The shunt revision rate was 22% for programmable pressure valves and 21% for fixed pressure valves (HR 1.1 [95% CI 0.6-1.8]). Shunt complications, such as valve failure, infection, and overdrainage, occurred with similar frequency across valve types. Kaplan-Meier survival curve analysis showed no difference in durability between fixed (mean 39 months) and programmable (mean 40 months) shunts (p = 0.980, log-rank test). The median shunt supply cost per index case and accounting for subsequent revisions was $3438 (interquartile range $2938-$3876) and $1504 (interquartile range $753-$1584) for programmable and fixed shunts, respectively (p < 0.001, Wilcoxon rank-sum test). Of all hydrocephalus etiologies, pseudotumor cerebri (HR 1.9 [95% CI 1.2-3.1]) and previous shunt malfunction (HR 1.8 [95% CI 1.2-2.7]) were found to significantly increase the risk of shunt revision. Within each diagnosis, there were no significant differences in revision rates between shunts with a fixed valve and shunts with a programmable valve. CONCLUSIONS Long-term shunt revision rates are similar for fixed and programmable shunt pressure valves in adult patients. Hydrocephalus etiology may play a significant role in predicting shunt revision, although programmable valves incur higher supply costs regardless of initial diagnosis. Utilization of fixed pressure valves versus programmable pressure valves may reduce supply costs while maintaining similar revision rates. Given the importance of developing cost-effective management protocols, this study highlights the critical need for large-scale prospective observational studies and randomized clinical trials of ventricular shunt valve revisions and additional patient-centered outcomes.
Revision open Bankart surgery after arthroscopic repair for traumatic anterior shoulder instability.
Cho, Nam Su; Yi, Jin Woong; Lee, Bong Gun; Rhee, Yong Girl
2009-11-01
Only a few studies have provided homogeneous analysis of open revision surgery after a failed arthroscopic Bankart procedure. Open Bankart revision surgery will be effective in a failed arthroscopic anterior stabilization but inevitably results in a loss of range of motion, especially external rotation. Case series; Level of evidence, 4. Twenty-six shoulders that went through traditional open Bankart repair as revision surgery after a failed arthroscopic Bankart procedure for traumatic anterior shoulder instability were enrolled for this study. The mean patient age at the time of revision surgery was 24 years (range, 16-38 years), and the mean duration of follow-up was 42 months (range, 25-97 months). The preoperative mean range of motion was 173 degrees in forward flexion and 65 degrees in external rotation at the side. After revision surgery, the ranges measured 164 degrees and 55 degrees, respectively (P = .024 and .012, respectively). At the last follow-up, the mean Rowe score was 81 points, with 88.5% of the patients reporting good or excellent results. After revision surgery, redislocation developed in 3 shoulders (11.5%), all of which had an engaging Hill-Sachs lesion and associated hyperlaxity (2+ or greater laxity on the sulcus sign). Open revision Bankart surgery for a failed arthroscopic Bankart repair can provide a satisfactory outcome, including a low recurrence rate and reliable functional return. In open revision Bankart surgery after failed stabilization for traumatic anterior shoulder instability, the surgeon should keep in mind the possibility of a postoperative loss of range of motion and a thorough examination for not only a Bankart lesion but also other associated lesions, including a bone defect or hyperlaxity, to lower the risk of redislocation.
Judith Turner; Philip Jennings; Sam McDonough; Debbie Liddell; Jackie Stonehouse
2006-01-01
A range of fungicides have been tested for activity against P. ramorum using both in vitro and in vivo tests. All fungicides had proven activity against Phytophthora species and either had full approval for use on hardy ornamental nursery stock in the United Kingdom, or could be used under the Revised Long Term Arrangements for Extension of Use (2002...
CMH-17 Volume 5 Ceramic Matrix Composites
NASA Technical Reports Server (NTRS)
Andrulonis, Rachael; Kiser, J. Douglas; David, Kaia E.; Davies, Curtis; Ashforth, Cindy
2017-01-01
A wide range of issues must be addressed during the process of certifying CMC (ceramic matrix composite) components for use in commercial aircraft. The Composite Materials Handbook-17, Volume 5, Revision A on ceramic matrix composites has just been revised to help support FAA certification of CMCs for elevated temperature applications. The handbook supports the development and use of CMCs through publishing and maintaining proven, reliable engineering information and standards that have been thoroughly reviewed. Volume 5 contains detailed sections describing CMC materials processing, design analysis guidelines, testing procedures, and data analysis and acceptance. A review of the content of this latest revision will be presented along with a description of how CMH-17, Volume 5 could be used by the FAA (Federal Aviation Administration) and others in the future.
Update on CMH-17 Volume 5 Ceramic Matrix Composites
NASA Technical Reports Server (NTRS)
Andrulonis, Rachael; Kiser, J. Douglas; David, Kaia E.; Davies, Curtis R.; Ashforth, Cindy
2017-01-01
A wide range of issues must be addressed during the process of certifying CMC (ceramic matrix composite) components for use in commercial aircraft. The Composite Materials Handbook-17, Volume 5, Revision A on ceramic matrix composites has just been revised to help support FAA certification of CMCs for elevated temperature applications. The handbook supports the development and use of CMCs through publishing and maintaining proven, reliable engineering information and standards that have been thoroughly reviewed. Volume 5 contains detailed sections describing CMC materialsprocessing design, analysisguidelines, testing procedures, and data analysis and acceptance. A review of the content of this latest revision will be presented along with a description of how CMH-17, Volume 5 could be used by the FAA (Federal Aviation Administration) and others in the future.
Betz, Cecily L; Cowell, Julia Muennich; Faulkner, Melissa Spezia; Feeg, Veronica D; Greenberg, Cindy Smith; Krajicek, Marilyn J; Lipman, Terri H; Lobo, Marie L; Nehring, Wendy M; Craft-Rosenberg, Martha; Vessey, Judith A
2016-01-01
This article details the process used to develop the revision of the original Guidelines that resulted in the development of the 2014 Health Care Quality and Outcomes Guidelines for Nursing of Children, Adolescents, and Families. Members of the 2014 Guidelines Revision Task Force conducted an extensive process of revision, which included the input and approval of 16 pediatric and child health nursing and affiliated organizational endorsements. The revised Guidelines were presented to and endorsed by the American Academy of Nursing Board. These Guidelines are designed for use by pediatric and child health nurses who work in a range of health care and community-based settings. The Guidelines are proposed to be used as a framework for nurse-directed services and intervention development and testing, as a model for undergraduate and graduate pediatric and child health nursing program curriculum development, and as the theoretical basis for nursing investigations on the care of children, adolescents, and families. Copyright © 2016 National Association of Pediatric Nurse Practitioners. Published by Elsevier Inc. All rights reserved.
Code of Fair Testing Practices in Education (Revised)
ERIC Educational Resources Information Center
Educational Measurement: Issues and Practice, 2005
2005-01-01
A note from the Working Group of the Joint Committee on Testing Practices: The "Code of Fair Testing Practices in Education (Code)" prepared by the Joint Committee on Testing Practices (JCTP) has just been revised for the first time since its initial introduction in 1988. The revision of the Code was inspired primarily by the revision of…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wood, Richard Thomas; Ewing, Paul D.
The U.S. Nuclear Regulatory Commission’s (NRC’s) regulations in Part 50, “Domestic Licensing of Production and Utilization Facilities,” of Title 10 of the Code of Federal Regulations (10 CFR Part 50) state that structures, systems, and components important to safety in a nuclear power plant are to be designed to accommodate the effects of environmental conditions (i.e., remain functional under all postulated service conditions) and that design control measures such as testing are to be used to check the adequacy of design. Regulatory Guide (RG) 1.180 was developed to provide guidance to licensees and applicants on methods acceptable to the NRCmore » staff for complying with the NRC’s regulations on design, installation, and testing practices for addressing the effects of electromagnetic and radio-frequency interference (EMI/RFI) and power surges on safety-related instrumentation and control (I&C) systems. The first revision of RG 1.180 was issued in January 2000 and a second revision was issued in October 2003*. The second revision differed from the first revision in endorsing Military Standard (MIL-STD)-461E and the International Electrotechnical Commission (IEC) Standard (Std) 61000 series of EMI/RFI test methods, extending the guidance to cover signal line testing, incorporating frequency ranges where portable communications devices are experiencing increasing use, and relaxing the operating envelopes (test levels) when experience and confirmatory research warranted. It also offered exemptions from specific test criteria based on technical considerations such as plant conditions and the intended location of the safety-related I&C equipment. Since the last revision, new requirements have been identified, associated RGs have been created and updated, and additional industry guidance has been developed. Additionally, the operational environment has changed with the increase in wireless communication technology for both personal (smartphone) and industrial (remote I&C) purposes. Also, specific concerns and issues with testing methods and methodologies have been identified that must be addressed. Further, most of the standards that serve as the basis for the RG have been revised. Therefore, the NRC’s Office of Regulatory Research has contracted with Oak Ridge National Laboratory (ORNL) to incorporate new information and resolve the identified issues under NRC-HQ-60-14-D-0015, “Update to RG 1.180, Revision 2, Guidelines for Evaluating Electromagnetic and Radio-Frequency Interference in Safety-Related Instrumentation and Control Systems.” The ultimate goal of this project is to provide NRC the technical basis for developing and publishing a new revision of the RG. The focus of Task 4 was for ORNL to identify and address any new or additional EMI/RFI issues that could potentially impact the EMC of I&C systems. More specifically, ORNL was to evaluate the impact of any new issue on safety equipment in their local environments and then determine whether the issues should be included and discussed in the revision to RG 1.180 that is currently under way.« less
The Promise and the Promises of Making in Science Education
ERIC Educational Resources Information Center
Bevan, Bronwyn
2017-01-01
"Making" is a rapidly emerging form of educational practice that involves the design, construction, testing, and revision of a wide variety of objects, using high and low technologies, and integrating a range of disciplines including art, science, engineering, and mathematics. It has garnered widespread interest and support in both…
Fondevila, M; Phillips, C; Santos, C; Freire Aradas, A; Vallone, P M; Butler, J M; Lareu, M V; Carracedo, A
2013-01-01
A revision of an established 34 SNP forensic ancestry test has been made by swapping the under-performing rs727811 component SNP with the highly informative rs3827760 that shows a near-fixed East Asian specific allele. We collated SNP variability data for the revised SNP set in 66 reference populations from 1000 Genomes and HGDP-CEPH panels and used this as reference data to analyse four U.S. populations showing a range of admixture patterns. The U.S. Hispanics sample in particular displayed heterogeneous values of co-ancestry between European, Native American and African contributors, likely to reflect in part, the way this disparate group is defined using cultural as well as population genetic parameters. The genotyping of over 700 U.S. population samples also provided the opportunity to thoroughly gauge peak mobility variation and peak height ratios observed from routine use of the single base extension chemistry of the 34-plex test. Finally, the genotyping of the widely used DNA profiling Standard Reference Material samples plus other control DNAs completes the audit of the 34-plex assay to allow forensic practitioners to apply this test more readily in their own laboratories. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Young Children's Participation and Environment Measure: Swedish Cultural Adaptation.
Åström, Frida Marie; Khetani, Mary; Axelsson, Anna Karin
2018-08-01
To culturally adapt and evaluate the psychometric properties of the Young Children's Participation and Environment Measure (YC-PEM) for use by caregivers of Swedish children with and without disabilities, aged 2-5 years. Thirteen cognitive interviews and two focus groups with caregivers of children with and without disabilities were conducted to evaluate the cultural relevance of YC-PEM content for use in Sweden. Per participant feedback, a revised version of the Swedish YC-PEM was created and pilot tested with caregivers of children with disabilities (n = 11) and children with typical development (n = 22). User feedback informed content revisions to 7% of items. Internal consistency estimates of the Swedish YC-PEM pilot version were acceptable and ranged from .70 to .92 for all but two of the YC-PEM scales. Mean percentage agreement between raters ranged from 47% to 93% across YC-PEM scales for inter-rater, and 44% to 86% for test-retest. One of twelve YC-PEM scales revealed significant group differences between young children with and without disabilities. This study contributes preliminary evidence for the use of some scales within a culturally adapted YC-PEM in Sweden. Further validation with larger samples will allow for parametric testing to evaluate its psychometric properties.
ERIC Educational Resources Information Center
Yoon, So Yoon
2011-01-01
Working under classical test theory (CTT) and item response theory (IRT) frameworks, this study investigated psychometric properties of the Revised Purdue Spatial Visualization Tests: Visualization of Rotations (Revised PSVT:R). The original version, the PSVT:R was designed by Guay (1976) to measure spatial visualization ability in…
Boehm Test of Basic Concepts-Revised. Review.
ERIC Educational Resources Information Center
Padula, Janice
1988-01-01
The manual for the Boehm Test of Basic Concepts-Revised (1986) is reviewed. The test measures a child's knowledge of relational concepts. The revised version, eliminating some imperfections of the original, will continue to be a useful test of verbal concept acquisition. Cautions necessary while using the test are discussed. (SLD)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peters, T. B.
An Extraction, Scrub, and Strip (ESS) test was performed on a sample of Salt Waste Processing Facility (SWPF) Caustic-Side Solvent Extraction (CSSX) solvent and salt simulant to determine cesium distribution ratios (D( Cs)), and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams; this data will be used by Parsons to help determine if the solvent is qualified for use at the SWPF. The ESS test showed acceptable performance of the solvent for extraction, scrub, and strip operations. The extraction D( Cs) measured 12.5, exceeding the required value of 8. This value is consistent with resultsmore » from previous ESS tests using similar solvent formulations. Similarly, scrub and strip cesium distribution ratios fell within acceptable ranges. This revision was created to correct an error. The previous revision used an incorrect set of temperature correction coefficients which resulted in slight deviations from the correct D( Cs) results.« less
One-stage Revision ACL reconstruction with hamstring autograft results in satisfactory outcome
Kejriwal, Ritwik; Buelow, Jens
2017-01-01
Objectives: Revision anterior cruciate ligament (ACL) reconstruction is associated with poorer outcomes and higher rerupture rates when compared to primary ACL reconstruction. There is also a significant heterogeneity in surgical technique, number of stages, and graft options. We report a large single surgeon case series with hamstring autograft as a graft option. Methods: Observational series of revision ACL reconstructions performed by the senior author between 2005 and 2015 was carried out. Chart reviews and clinic follow-ups were performed with the following recorded – re-rupture rate, radiographic grading of osteoarthritis, KT-1000 arthrometer test, IKDC outcome scores and knee range of motion. All patients underwent single bundle four-strand hamstring autograft performed in one stage with use of new tunnels in majority of the cases. Results: 66 patients underwent hamstring autograft one-stage revision ACL reconstruction by Dr Jens Buelow. Chart review was carried out on all patients, and 26 (39%) were followed up in clinic and/or by phone with a mean follow up of 4.7 years. Outcomes included re-rupture rate of 4.5%, reoperation rate of 12%, mean visual analogue scale score of 7.6, mean side-to-side difference of 2.6 mm for KT-1000 arthrometer test, and mean IKDC score of 79. Of the 17 patients with radiographs, 40% had moderate osteoarthritis (grade 2 or 3) at follow-up. Conclusion: Revision ACL reconstruction can result in a satisfactory outcome when performed with a hamstring autograft in one stage.
Clinical Trial Results Summary for Laypersons: A User Testing Study.
Raynor, D K; Myers, L; Blackwell, K; Kress, B; Dubost, A; Joos, A
2018-01-01
To apply "user testing" to maximize readability and acceptability of a Clinical Trial Results Laypersons Summary-a new European requirement. "User testing" (using questionnaire and semistructured interview) assessed whether people could find and understand key points. Findings were used to improve content and design, prior to retesting. Participants had a range of levels of health literacy and there was a higher education group. Participants accessed the summary on screen. In round 1 we tested 12 points of information. In round 2 a revised summary addressing round 1 findings was tested, leading to a third final version. In round 1, 2 of 12 points of information did not reach the target and interviews raised further format and content issues (some distracting technical explanations and inability to find or understand the 2 main study purposes). These findings informed revisions for the version tested in round 2, with 2 different points not reaching the target (inclusion criteria relating to duration of seasonal allergies and how researchers found out about participants' symptoms). Identified problems in both rounds were addressed and reflected in the final version. Despite improvements, participants did not consistently understand that summaries were intended for the public, or to only interpret results of single trials in the context of additional trials. All readers, including those with higher education, found the clear and straightforward language acceptable. Applying "user testing" resulted in a largely health-literate summary suitable for people across a range of backgrounds.
ERIC Educational Resources Information Center
Tabachnick, Barbara Gerson
1979-01-01
The study was designed to investigate scatter produced by 105 learning disabled (LD) children (6 to 16 years old) and to compare Wechsler Intelligence Scale for Children-Revised (WISC-R) scatter with that produced by A. Kaufman's (1976) normal population. Range of scaled scores (i.e., scatter) was significantly greater for the LD group. (SBH)
Code of Federal Regulations, 2012 CFR
2012-07-01
... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) WATER PROGRAMS (CONTINUED) GUIDELINES ESTABLISHING TEST PROCEDURES... to a wide variety of sample types ranging from reagent (blank) water containing analyte to wastewater... times the standard deviation of replicate instrumental measurements of the analyte in reagent water. (c...
Revision and psychometric testing of the City of Hope Quality of Life-Ostomy Questionnaire.
Grant, Marcia; Ferrell, Betty; Dean, Grace; Uman, Gwen; Chu, David; Krouse, Robert
2004-10-01
Ostomies may be performed for bowel or urinary diversion, and occur in both cancer and non-cancer patients. Impact on physical, psychological, social and spiritual well-being is not unexpected, but has been minimally described in the literature. The City of Hope Quality of Life (COH-QOL)-Ostomy Questionnaire is an adult patient self-report instrument designed to assess quality of life. This report focuses on the revision and psychometric testing of this questionnaire. The revised COH-QOL-Ostomy Questionnaire involved in-depth patient interviews and expert panel review. The format consisted of a 13-item disease and demographic section, a 34-item forced-choice section, and a 41-item linear analogue scaled section. A mailed survey to California members of the United Ostomy Association resulted in a 62% response rate (n = 1513). Factor analysis was conducted to refine the instrument. Construct validity involved testing a number of hypotheses identifying contrasting groups. Factor analysis confirmed the conceptual framework. Reliability of subscales ranged from 0.77 to 0.90. The questionnaire discriminated between subpopulations with specific concerns. Overall, the analyses provide evidence for the validity and reliability of the COH-QOL-Ostomy Questionnaire as a comprehensive, multidimensional self-report questionnaire for measuring quality of life in patients with intestinal ostomies.
Failure after reverse total shoulder arthroplasty: what is the success of component revision?
Black, Eric M; Roberts, Susanne M; Siegel, Elana; Yannopoulos, Paul; Higgins, Laurence D; Warner, Jon J P
2015-12-01
Complication rates remain high after reverse total shoulder arthroplasty (RTSA). Salvage options after implant failure have not been well defined. This study examines the role of reimplantation and revision RTSA after failed RTSA, reporting outcomes and complications of this salvage technique. Sixteen patients underwent component revision and reimplantation after a prior failed RTSA from 2004 to 2011. Indications included baseplate failure (7 patients, 43.8%), instability (6 patients, 37.5%), infection (2 patients, 12.5%), and humeral loosening (1 patient, 6.3%). The average age of the patient during revision surgery was 68.6 years. Outcomes information at follow-up was recorded, including visual analog scale score for pain, subjective shoulder value, American Shoulder and Elbow Surgeons score, and Simple Shoulder Test score, and these were compared with pre-revision values. Repeated surgeries and complications were noted. Average time to follow-up from revision was 58.9 months (minimum, 2 years; range, 24-103 months). The average postoperative visual analog scale score for pain was 1.7/10 (7.5/10 preoperatively; P < .0001), and the subjective shoulder value was 62% (17% preoperatively; P < .0001). The average postoperative American Shoulder and Elbow Surgeons score was 66.7, and the Simple Shoulder Test score was 52.6. Fourteen patients (88%) noted that they felt "better" postoperatively than before their original RTSA and would go through the procedure again if given the option. Nine patients suffered major complications (56%), and 6 of these ultimately underwent further procedures (38% of cohort). Salvage options after failure of RTSA remain limited. Component revision and reimplantation can effectively relieve pain and improve function compared with baseline values, and patient satisfaction levels are moderately high. However, complication rates and reoperation rates are significant. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Axelson, John A.; Emerson, Horace F.
1949-01-01
High-speed wind-tunnel tests were conducted of two versions of a 0.17-scale model of the McDonnell XF2H-1 airplane to ascertain the high-speed stability and control characteristics and to study means for raising the high-speed buffet limit of the airplane, The results for the revised model, employing a thinner wing and tail than the original model, revealed a mild diving tendency from 0.75 to 0.80 Mach number, followed by a marked climbing tendency from 0.80 to 0.875 Mach number. The high-speed climbing tendency was caused principally by the pitching-moment characteristics of the wing. At 0.875 Mach number the results for the revised model indicated stick-fixed directional instability over a limited range of yaw angles, apparently caused by separated flow over the vertical tail. The test results indicate that the high-speed buffet limit of the airplane can probably be raised by reducing the thickness and changing the relative location of the horizontal and vertical tails, and by revising the inner portion of the wing to have a lower thickness-to-chord ratio and reduced trailing-edge angle. The addition of the wing-tip tanks to the revised model resulted in a forward shift in the neutral point below 0.82 Mach number.
Smith, David; Harvey, Peter; Lawn, Sharon; Harris, Melanie; Battersby, Malcolm
2017-01-01
To evaluate the factor structure of the revised Partners in Health (PIH) scale for measuring chronic condition self-management in a representative sample from the Australian community. A series of consultations between clinical groups underpinned the revision of the PIH. The factors in the revised instrument were proposed to be: knowledge of illness and treatment, patient-health professional partnership, recognition and management of symptoms and coping with chronic illness. Participants (N = 904) reporting having a chronic illness completed the revised 12-item scale. Two a priori models, the 4-factor and bi-factor models were then evaluated using Bayesian confirmatory factor analysis (BCFA). Final model selection was established on model complexity, posterior predictive p values and deviance information criterion. Both 4-factor and bi-factor BCFA models with small informative priors for cross-loadings provided an acceptable fit with the data. The 4-factor model was shown to provide a better and more parsimonious fit with the observed data in terms of substantive theory. McDonald's omega coefficients indicated that the reliability of subscale raw scores was mostly in the acceptable range. The findings showed that the PIH scale is a relevant and structurally valid instrument for measuring chronic condition self-management in an Australian community. The PIH scale may help health professionals to introduce the concept of self-management to their patients and provide assessment of areas of self-management. A limitation is the narrow range of validated PIH measurement properties to date. Further research is needed to evaluate other important properties such as test-retest reliability, responsiveness over time and content validity.
ERIC Educational Resources Information Center
Mowder, Barbara A.; Shamah, Renee
2011-01-01
This study evaluated the test-retest reliability of two parenting measures: the Parent Behavior Importance Questionnaire-Revised (PBIQ-R) and Parent Behavior Frequency Questionnaire-Revised (PBFQ-R). These self-report parenting behavior assessment measures may be utilized as pre- and post-parent education program measures, with parents as well as…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-20
..., closures and coils, from graphic arts operations, from the provision of sampling and testing facilities... Provision of Sampling and Revised 03/21/01....... 05/31/01 Testing Facilities. AVAQMD 1168 Adhesive and... District (1) Rule 205, ``Provision of Sampling and Testing Facilities,'' revised on March 21, 2001...
Hyperion 5113/A Infrasound Sensor Evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Merchant, Bion John
2015-09-01
Sandia National Laboratories has tested and evaluated an infrasound sensor, the 5113/A manufactured by Hyperion. These infrasound sensors measure pressure output by a methodology developed by the University of Mississippi. The purpose of the infrasound sensor evaluation was to determine a measured sensitivity, transfer function, power, self-noise, and dynamic range. The 5113/A infrasound sensor is a new revision of the 5000 series intended to meet the infrasound application requirements for use in the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kidman, Raymond; Matthews, Patrick
The purpose of this Corrective Action Decision Document/Closure Report is to provide justification and documentation supporting the recommendation that no further corrective action is needed for CAU 541 based on the no further action alternative listed in Table ES-1.
Item Bank Development for a Revised Pediatric Evaluation of Disability Inventory (PEDI)
ERIC Educational Resources Information Center
Dumas, Helene; Fragala-Pinkham, Maria; Haley, Stephen; Coster, Wendy; Kramer, Jessica; Kao, Ying-Chia; Moed, Richard
2010-01-01
The Pediatric Evaluation of Disability Inventory (PEDI) is a useful clinical and research assessment, but it has limitations in content, age range, and efficiency. The purpose of this article is to describe the development of the item bank for a new computer adaptive testing version of the PEDI (PEDI-CAT). An expanded item set and response options…
The Differences of Mathematics Achievement between American Children and Chinese Children.
ERIC Educational Resources Information Center
Gu, Wenyuan
This study compared intact beginning fifth grade classes in one of the districts in Shanghai, People's Republic of China to American Norms on the KeyMath-Revised: A Diagnostic Inventory of Essential Mathematics (KeyMath-R) and the Wide Range Achievement Test (WRAT-3). The review of literature contrasted the two cultures with regard to students,…
Long-term outcomes after primary failures of artificial urinary sphincter implantation.
Wang, Rou; McGuire, Edward J; He, Chang; Faerber, Gary J; Latini, Jerilyn M
2012-04-01
To assess our institutional outcomes after primary artificial urinary sphincter (AUS) failures. From 1985 to 2010, a total of 149 patients underwent 318 primary and additional AUS procedures. We classified additional procedures as revisions, replacements, or explantations. At a median of 52 months (range, 6-250 months), 53% of patients had required at least 1 additional procedure beyond their initial implantation. These included 106 (63%) revisions, 42 (24.9%) explantations, and 21 (12.4%) replacements. The most common revision was reservoir upsizing (37/106). Reasons for first revision included recurrent incontinence (56.7%), mechanical malfunction (22%), and infection or erosion (18.6%). Explantations were performed primarily for infection and erosion (64.3%). Median time to first revision was 20.1 months (range, 0.1-173 months) after implantation, with a median of 9.5 months (range, 1-102 months) between revisions. Explantation occurred at a median of 22 months (range, 1-221 months) after implant, and subsequent replacement at a median of 33.6 months (range, 2-138 months). At 5 years, 28/83 (33.7%) patients had undergone no additional procedures. Patients with previous radiation were more likely to experience infection (P = .03; OR 3.99; 95% CI 1.03-15.42). Patients with previous myocardial infarction were more likely to experience erosion (P = .04; OR 2.29; 95% CI 1.05-5.02), and obese patients were more likely to experience mechanical malfunction (P = .04; OR 2.62; 95% CI 1.07-6.4). More than half of patients with an AUS will require additional procedures, most likely revision. Radiation, previous myocardial infarction, and obesity are linked to complications. Median time to first revision or explantation is slightly less than 2 years, indicating that long-term follow-up is required after initial implantation. Copyright © 2012 Elsevier Inc. All rights reserved.
Perera, Subashan; Nace, David A; Resnick, Neil M; Greenspan, Susan L
2017-04-11
The Nursing Home Physical Performance Test (NHPPT) was developed to measure function among nursing home residents using sit-to-stand, scooping applesauce, face washing, dialing phone, putting on sweater, and ambulating tasks. Using item response theory, we explore its measurement characteristics at item level and opportunities for improvements. We used data from long-term care women. We fitted a graded response model, estimated parameters, and constructed probability and information curves. We identified items to be targeted toward lower and higher functioning persons to increase the range of abilities to which the instrument is applicable. We revised the scoring by making sit-to-stand and sweater items harder and dialing phone easier. We examined changes to concurrent validity with activities of daily living (ADL), frailty, and cognitive function. Participants were 86 years old, had more than three comorbidities, and a NHPPT of 19.4. All items had high discrimination and were targeted toward the lower middle range of performance continuum. After revision, sit-to-stand and sweater items demonstrated greater discrimination among the higher functioning and/or greater spread of thresholds for response categories. The overall test showed discrimination over a wider range of individuals. Concurrent validity correlation improved from 0.60 to 0.68 for instrumental ADL and explained variability (R2) from 22% to 36% for frailty. NHPPT has good measurement characteristics at the item level. NHPPT can be improved, implemented in computerized adaptive testing, and combined with self-report for greater utility, but a definitive study is needed. © The Author 2017. Published by Oxford University Press on behalf of The Gerontological Society of America. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Bush, Shane S; Sweet, Jerry J; Bianchini, Kevin J; Johnson-Greene, Doug; Dean, Pamela M; Schoenberg, Mike R
2018-04-01
Neuropsychological tests undergo periodic revision intended to improve psychometric properties, normative data, relevance of stimuli, and ease of administration. In addition, new tests are developed to evaluate psychological and neuropsychological constructs, often purporting to improve evaluation effectiveness. However, there is limited professional guidance to neuropsychologists concerning the decision to adopt a revised version of a test and/or replace an older test with a new test purporting to measure the same or overlapping constructs. This paper describes ethical and professional issues related to the selection and use of older versus newer psychological and neuropsychological tests, with the goal of promoting appropriate test selection and evidence-based decision making. Ethical and professional issues were reviewed and considered. The availability of a newer version of a test does not necessarily render obsolete prior versions of the test for purposes that are empirically supported, nor should continued empirically supported use of a prior version of a test be considered unethical practice. Until a revised or new test has published evidence of improved ability to help clinicians to make diagnostic determinations, facilitate treatment, and/or assess change over time, the choice to delay adoption of revised or new tests may be viewed as reasonable and appropriate. Recommendations are offered to facilitate decisions about the adoption of revised and new tests. Ultimately, it is the responsibility of individual neuropsychologists to determine which tests best meet their patients' needs, and to be able to support their decisions with empirical evidence and sound clinical judgment.
Smart, Jennifer I; Corey, Gordon Ralph; Stryjewski, Martin E; Wang, Whedy; Barriere, Steven L
2016-12-01
The broth microdilution method (BMD) for testing telavancin minimum inhibitory concentrations (MICs) was revised (rBMD) in 2014 to improve the accuracy, precision, and reproducibility of the testing method. The aim of this study was to determine the effect of the revised method on telavancin MIC values for Staphylococcus aureus (S. aureus) clinical isolates obtained from hospital-acquired pneumonia (HAP) patients. Isolates from patients who participated in the phase 3 Assessment of Telavancin for Treatment of HAP Studies were retested using the rBMD method. Retesting of 647 isolates produced a range of telavancin MIC values from 0.015 µg/mL to 0.12 µg/mL with MIC 50/90 values of 0.06/0.06 µg/mL for the total pool of samples. For methicillin-resistant S. aureus (MRSA), MIC 50/90 values were 0.06/0.12 µg/mL. These values are up to 4-fold lower than MIC 50/90 values obtained using the original method. These results were used in part to justify lowering the telavancin breakpoints. All tested isolates remained susceptible to telavancin at the revised susceptibility breakpoint of ≤0.12 µg/mL. Overall, the clinical cure rate for microbiologically evaluable telavancin-treated patients was 78% for S. aureus, 76% for patients with MRSA, and 79% for patients with isolates with reduced susceptibility to vancomycin (MIC ≥1 µg/mL). Results from the rBMD method support the in vitro potency of telavancin against S. aureus. ATTAIN (NCT00107952 and NCT00124020). Theravance Biopharma Antibiotics, Inc.
ERIC Educational Resources Information Center
Plake, Barbara S.; Wise, Lauress L.
2014-01-01
With the 2014 publication of the 5th revision of the "Standards for Educational and Psychological Testing," the cochairs of the Joint Committee for the revision process were asked to consider the role and importance of the "Standards" for the educational testing community, and in particular for members of the National Council…
2007-05-01
Bioaugmentation of Source Areas Dover National Test Site, Dover, Delaware ESTCP Project Number ER-0008 May 2007 Revision 3.0 ER0008 ii...2007.05.24 Revision 3.0 TABLE OF CONTENTS Page 1. INTRODUCTION...ER0008 iii 2007.05.24 Revision 3.0 3.5 Testing and Evaluation Plan
[Reliability and validity of Meaningful Life Measure-Chinese Revised in Chinese college students].
Xiao, Rong; Lai, Qiao-Zhen; Yang, Jia-Ping
2016-04-20
To test the reliability and validity of Meaningful Life Measure-Chinese Revised (MLM-CR) in Chinese college students. A total of 1035 college students were evaluated with MLM-CR, Satisfaction with Life Scale (SWLS), Purpose in Life (PIL) and Patient Health Questionnaire-2 (PHQ-2), and 120 of the students were examined with PIL-SF twice. All the items in MLM-CR had good discrimination indexes (r=0.753-0.838, P<0.001). Confirmatory factor analysis confirmed the hypothesized five-factor model of MLM-CR (Χ 2 /df=3.4, GFI=0.946, AGFI=0.924, RMR=0.069, NFI=0.953, CFI=0.966, RMSEA=0.048). The total internal consistency reliability of MLM-CR was 0.942, and the alpha coefficients of the 5 dimensions ranged from 0.782 to 0.877; the total split-half reliability was 0.920, and the split-half reliability of the 5 dimensions ranged from 0.752 to 0.830; the total test-retest reliability was 0.871, and the test-retest reliability of the 5 dimensions ranged from 0.783 to 0.805. The criterion validity of MLM-CR in correlation with SWLS, PIL and PHQ-2 was 0.66, 0.755 and -0.388, respectively (P<0.01). The Average score of MLM-CR of the college students was 5.20∓0.90, and the scores were significantly higher in female students than in the male students (P<0.001). MLM-CR has good psychometric properties for application in comprehensive evaluation of personal meaning in life.
Long-term follow-up of shoulder hemiarthroplasty for glenohumeral osteoarthritis.
Levine, William N; Fischer, Charla R; Nguyen, Duong; Flatow, Evan L; Ahmad, Christopher S; Bigliani, Louis U
2012-11-21
There is major controversy surrounding the use of hemiarthroplasty as compared with total shoulder arthroplasty for glenohumeral osteoarthritis, and long-term clinical outcomes of hemiarthroplasty are lacking. Of a cohort of thirty patients (thirty-one shoulders) who were treated with hemiarthroplasty for glenohumeral osteoarthritis and followed longitudinally at our institution, twenty-five were available for long-term follow-up; five died, and one refused to participate. Three of the five patients who died had revision arthroplasty before death, and the data from those three were therefore included in the final follow-up (final follow-up data therefore included twenty-seven patients and twenty-eight shoulders). Follow-up through phone conversations and postal mail surveys included the following: Short Form-36, American Shoulder and Elbow Surgeons (ASES) shoulder outcome score, EuroQol, Simple Shoulder Test, modified Neer Score, and a unique, validated self-administered range-of-motion questionnaire. Correlations between clinical outcome and age, type of glenoid wear, and cause of osteoarthritis were determined. The average follow-up was 17.2 years (range, thirteen to twenty-one years). There were eight revisions (three of fifteen shoulders with concentric glenoids, and five of sixteen shoulders with eccentric glenoids). For those shoulders not revised, the average ASES score was 70.54 (range, 36.67 to 91.67). Overall, active shoulder forward elevation and external rotation with the arm at 90° of abduction increased from 104° preoperatively to 141.8° (range, 45° to 180°) and 20.7° to 61.0° (range, 30° to 90°), respectively (p < 0.05), at the time of final follow-up. Of those who required revision arthroplasty, the average patient age at the time of the index procedure was 51.0 years (range, twenty-six to eighty-one years), while those not requiring revision averaged 57.1 years (range, twenty-seven to sixty-three years). The overall Neer satisfaction rating was 25%. The average Neer score and Neer rating for unrevised cases were significantly higher for concentric glenoid wear compared with eccentric glenoid wear (p = 0.015 and p = 0.001, respectively). Patients who had concentric glenoid wear had higher EuroQol scores (p = 0.020). The average Neer scores were 65.29 (range, forty-seven to seventy-eight) for primary osteoarthritis and 54.46 (range, forty to seventy-seven) for secondary osteoarthritis (p = 0.036). Only 25% of patients with glenohumeral osteoarthritis treated with shoulder hemiarthroplasty are satisfied with their outcome at an average of seventeen years after the operation. Patients with concentric glenoid wear and primary osteoarthritis have better outcomes than those with eccentric glenoid wear and secondary osteoarthritis do, but patients in both groups experienced deterioration of results over time. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Retrofit and verification test of a 30-cm ion thruster
NASA Technical Reports Server (NTRS)
Dulgeroff, C. R.; Poeschel, R. L.
1980-01-01
Twenty modifications were found to be necessary and were approved by design review. These design modifications were incorporated in the thruster documents (drawings and procedures) to define the J series thruster. Sixteen of the design revisions were implemented in a 900 series thruster by retrofit modification. A standardized set of test procedures was formulated, and the retrofit J series thruster design was verified by test. Some difficulty was observed with the modification to the ion optics assembly, but the overall effect of the design modification satisfies the design objectives. The thruster was tested over a wide range of operating parameters to demonstrate its capabilities.
ERIC Educational Resources Information Center
Maeda, Yukiko; Yoon, So Yoon
2016-01-01
We investigated the extent to which the observed gender differences in mental rotation ability among the 2,468 freshmen studying engineering at a Midwest public university attributed to the gender bias of a test. The Revised Purdue Spatial Visualization Tests: Visualization of Rotations (Revised PSVT:R) is a spatial test frequently used to measure…
Outcome of prosthesis exchange for infected knee arthroplasty: the effect of treatment approach.
Jämsen, Esa; Stogiannidis, Ioannis; Malmivaara, Antti; Pajamäki, Jorma; Puolakka, Timo; Konttinen, Yrjö T
2009-02-01
Two-stage revision remains the gold standard in the treatment of infected knee arthroplasty. Lately, good long-term results of direct exchange arthroplasty have been reported. The purpose of this literature review is to compare the clinical outcome achieved with one-stage revision and two-stage revision with different types of spacers. A thorough systematic review of literature was undertaken to idenepsy reports on the treatment alternatives. Papers written in English or including an English abstract, published from 1980 through 2005, and reporting either the success rate in eradication of infection or the clinical status achieved were reviewed. 31 original articles describing the results of 154 one-stage exchange arthoplasties and of 926 two-stage exchange arthoplasties were included. The depth of detail in the description of materials and methods varied markedly, making it impossible to perform a meta-analysis. Instead, a descriptive review of the results is presented. With a follow-up of 12-122 months, the overall success rate in eradication of infection was 73-100% after one-stage revisions and 82-100% after two-stage revisions. Reinfection rates were the lowest in series where articulating cement spacers were used, though the follow-up was relatively short. Studies using articulating spacers reported the highest average postoperative ranges of motion. Otherwise, no correlations were observed between the clinical outcome and the length of follow-up, the type of revision, or the type of spacer. The clinical outcome (knee scores and range of motion) of the one-stage revisions was no different from that of the two-stage revisions. Two-stage exchange is an effective treatment. Mobile spacers may further improve the range of motion. More experience in one-stage revision is required in order to define its role in the management of infected knee arthroplasties.
Results of press-fit stems in revision knee arthroplasties.
Wood, Gavin C; Naudie, Douglas D R; MacDonald, Steven J; McCalden, Richard W; Bourne, Robert B
2009-03-01
The ideal method of stem fixation in revision knee arthroplasty is controversial with advantages and disadvantages for cemented and press-fit designs. Studies have suggested cemented revision knee stems may provide better long-term survival. The aim of this study was to report our experience with press-fit uncemented stems and metaphyseal cement fixation in a selected series of patients undergoing revision total knee arthroplasty. One hundred twenty-seven patients (135 knees) who underwent revision total knee arthroplasty using a press-fit technique (press-fit diaphyseal fixation and cemented metaphyseal fixation) were reviewed. Minimum followup was 2 years (mean, 5 years; range, 2-12 years). A Kaplan-Meier survivorship analysis using an end point of revision surgery or radiographic loosening was used to determine probability of survival at 5 and 10 years. Of the 127 patients (135 knees), 31 patients (36 knees) died and two patients (two knees) were lost to followup. Six patients (six knees) had revisions at a mean of 3.5 years (range, 1-8 years). Kaplan-Meier survivorship analysis revealed a probability of survival free of revision for aseptic loosening of 98% at 12 years. Survivorship of press-fit stems for revision knee arthroplasty is comparable to reported survivorship of cemented stem revision knee arthroplasty. Radiographic analysis has shown continued satisfactory appearances regardless of constraint, stem size, and augmentations.
Zdero, Radovan; Saidi, Kevan; Mason, Stephanie A; Schemitsch, Emil H; Naudie, Douglas D R
2012-11-01
Few biomechanical studies exist on femoral cementless press-fit stems for revision total knee replacement (TKR) surgeries. The aim of this study was to compare the mechanical quality of the femur-stem interface for a series of commercially available press-fit stems, because this interface may be a 'weak link' which could fail earlier than the femur-TKR bond itself. Also, the femur-stem interface may become particularly critical if distal femur bone degeneration, which may necessitate or follow revision TKR, ever weakens the femur-TKR bond itself. The authors implanted five synthetic femurs each with a Sigma Short Stem (SSS), Sigma Long Stem (SLS), Genesis II Short Stem (GSS), or Genesis II Long Stem (GLS). Axial stiffness, lateral stiffness, 'offset load' torsional stiffness, and 'offset load' torsional strength were measured with a mechanical testing system using displacement control. Axial (range = 1047-1461 N/mm, p = 0.106), lateral (range = 415-462 N/mm, p = 0.297), and torsional (range = 115-139 N/mm, p > 0.055) stiffnesses were not different between groups. The SSS had higher torsional strength (863 N) than the other stems (range = 167-197 N, p < 0.001). Torsional failure occurred by femoral 'spin' around the stem's long axis. There was poor linear correlation between the femur-stem interface area versus axial stiffness (R = 0.38) and torsional stiffness (R = 0.38), and there was a moderate linear correlation versus torsional strength (R = 0.55). Yet, there was a high inverse linear correlation between interfacial surface area versus lateral stiffness (R = 0.79), although this did not result in a statistical difference between stem groups (p = 0.297). These press-fit stems provide equivalent stability, except that the SSS has greater torsional strength.
2011-07-28
missions. It was recognized that a failure to remove the trees could result in valuable data loss on Eglin test missions. Four different methods have...4-57 to 4-59) The munitions used on TA C-72 would cause noise levels ofless than 115 P- weighted (impulse sound) decibels, and receptors would not...approximate calculation is: 600 x the cube root of the net explosive weight (NEW) = distance to the reservation boundary (infeet) . No detonation can
78 FR 39190 - Revisions to Fitness for Duty Programs' Drug Testing Requirements
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-01
...-0225] RIN 3150-AI67 Revisions to Fitness for Duty Programs' Drug Testing Requirements AGENCY: Nuclear... regarding drug testing requirements in NRC licensees' fitness for duty programs. The regulatory basis...
Peabody Picture Vocabulary Test-Revised (PPVT-R).
ERIC Educational Resources Information Center
Vance, H. Robert; Stone, J. E.
1990-01-01
The Peabody Picture Vocabulary Test-Revised assesses standard American English receptive vocabulary in individuals, both handicapped and nonhandicapped, ages 2 to 40. This paper describes the test's administration, summation of data, standardization, reliability, and validity. (JDD)
ERIC Educational Resources Information Center
Stirling, Diane
This character-education guide, for grades Pre-K through 12, presents field-generated, field-tested ideas for integrating character education with daily learning. The ideas are varied in design, scope, and developmental levels, and range from half-hour lessons to schoolwide events to year-long courses. Each unit (50 in all) is built on particular…
Dejour, David; Saffarini, Mo; Demey, Guillaume; Baverel, Laurent
2015-10-01
Revision ACL reconstruction requires careful analysis of failure causes particularly in cases of two previous graft ruptures. Intrinsic factors as excessive tibial slope or narrow femoral notch increase failure risks but are rarely addressed in revision surgery. The authors report outcomes, at minimum follow-up of 2 years, for second revision ACL reconstructions combined with tibial deflexion osteotomy for correction of excessive slope (>12°). Nine patients that underwent second revision ACL reconstruction combined with tibial deflexion osteotomy were retrospectively studied. The mean age was 30.3 ± 4.4 years (median 28; range 26-37), and mean follow-up was 4.0 ± 2.0 years (median 3.6; range 2.0-7.6). Autografts were harvested from the quadriceps tendon (n = 8) or hamstrings (n = 1), and tibial osteotomy was done by anterior closing wedge, without detachment of the patellar tendon, to obtain a slope of 3° to 5°. All patients had fused osteotomies, stable knees, and there were no intraoperative or postoperative complications. The mean posterior tibial slope decreased from 13.2° ± 2.6° (median 13°; range 12°-18°) preoperatively to 4.4° ± 2.3° (median 4°; range 2°-8°) postoperatively. The mean Lysholm score was 73.8 ± 5.8 (median 74; range 65-82), and the IKDC-SKF was 71.6 ± 6.1 (median 72.8; range 62.2-78.5). The satisfactory results of second revision ACL reconstruction combined with tibial deflexion osteotomy at minimum follow-up of 2 years suggest that tibia slope correction protects reconstructed ACL from fatigue failure in this study. The authors stress the importance of careful analysis failure causes prior to revision ACL reconstruction, and recommend correction of tibial slope if it exceeds 12°, to reduce the risks of graft retear. III.
Copper benchmark experiment for the testing of JEFF-3.2 nuclear data for fusion applications
NASA Astrophysics Data System (ADS)
Angelone, M.; Flammini, D.; Loreti, S.; Moro, F.; Pillon, M.; Villar, R.; Klix, A.; Fischer, U.; Kodeli, I.; Perel, R. L.; Pohorecky, W.
2017-09-01
A neutronics benchmark experiment on a pure Copper block (dimensions 60 × 70 × 70 cm3) aimed at testing and validating the recent nuclear data libraries for fusion applications was performed in the frame of the European Fusion Program at the 14 MeV ENEA Frascati Neutron Generator (FNG). Reaction rates, neutron flux spectra and doses were measured using different experimental techniques (e.g. activation foils techniques, NE213 scintillator and thermoluminescent detectors). This paper first summarizes the analyses of the experiment carried-out using the MCNP5 Monte Carlo code and the European JEFF-3.2 library. Large discrepancies between calculation (C) and experiment (E) were found for the reaction rates both in the high and low neutron energy range. The analysis was complemented by sensitivity/uncertainty analyses (S/U) using the deterministic and Monte Carlo SUSD3D and MCSEN codes, respectively. The S/U analyses enabled to identify the cross sections and energy ranges which are mostly affecting the calculated responses. The largest discrepancy among the C/E values was observed for the thermal (capture) reactions indicating severe deficiencies in the 63,65Cu capture and elastic cross sections at lower rather than at high energy. Deterministic and MC codes produced similar results. The 14 MeV copper experiment and its analysis thus calls for a revision of the JEFF-3.2 copper cross section and covariance data evaluation. A new analysis of the experiment was performed with the MCNP5 code using the revised JEFF-3.3-T2 library released by NEA and a new, not yet distributed, revised JEFF-3.2 Cu evaluation produced by KIT. A noticeable improvement of the C/E results was obtained with both new libraries.
Alwinesh, Merlin Thanka Jemi; Joseph, Rachel Beulah Jansirani; Daniel, Anna; Abel, Julie Sandra; Shankar, Satya Raj; Mammen, Priya; Russell, Sushila; Russell, Paul Swamidhas Sudhakar
2012-09-01
There is no agreement about the measure to quantify the intellectual/developmental level in children with the dual disability of intellectual disability and autism. Therefore, we studied the psychometric properties and utility of Psycho-Educational Profile-Revised (PEP-R) as a developmental test in this population. We identified 116 children with dual disability from the day care and inpatient database of a specialised Autism Clinic. Scale and domain level scores of PEP-R were collected and analyzed. We examined the internal consistency, domain-total correlation of PEP-R and concurrent validity of PEP-R against Gesell's Developmental Schedule, inter-rater and test-retest reliability and utility of PEP-R among children with dual disability in different ages, functional level and severity of autism. Besides the adequate face and content validity, PEP-R demonstrates a good internal consistency (Cronbach's α ranging from 0.91 to 0.93) and domain-total correlation (ranging from 0.75 to 0.90). The inter-rater reliability (intraclass correlation coefficient, ICC = 0.96) and test-retest reliability (ICC = 0.87) for PEP-R is good. There is moderate-to-high concurrent validity with GDS (r ranging from 0.61 to 0.82; all Ps = 0.001). The utility of PEP-R as a developmental measure was good with infants, toddlers, pre-school and primary school children. The ability of PEP-R to measure the developmental age was good, irrespective of the severity of autism but was better with high-functioning children. The PEP-R as an intellectual/developmental test has strong psychometric properties in children with dual disability. It could be used in children with different age groups and severity of autism. PEP-R should be used with caution as a developmental test in children with dual disability who are low functioning.
A New Clinical Pain Knowledge Test for Nurses: Development and Psychometric Evaluation.
Bernhofer, Esther I; St Marie, Barbara; Bena, James F
2017-08-01
All nurses care for patients with pain, and pain management knowledge and attitude surveys for nurses have been around since 1987. However, no validated knowledge test exists to measure postlicensure clinicians' knowledge of the core competencies of pain management in current complex patient populations. To develop and test the psychometric properties of an instrument designed to measure pain management knowledge of postlicensure nurses. Psychometric instrument validation. Four large Midwestern U.S. hospitals. Registered nurses employed full time and part time August 2015 to April 2016, aged M = 43.25 years; time as RN, M = 16.13 years. Prospective survey design using e-mail to invite nurses to take an electronic multiple choice pain knowledge test. Content validity of initial 36-item test "very good" (95.1% agreement). Completed tests that met analysis criteria, N = 747. Mean initial test score, 69.4% correct (range 27.8-97.2). After revision/removal of 13 unacceptable questions, mean test score was 50.4% correct (range 8.7-82.6). Initial test item percent difficulty range was 15.2%-98.1%; discrimination values range, 0.03-0.50; final test item percent difficulty range, 17.6%-91.1%, discrimination values range, -0.04 to 1.04. Split-half reliability final test was 0.66. A high decision consistency reliability was identified, with test cut-score of 75%. The final 23-item Clinical Pain Knowledge Test has acceptable discrimination, difficulty, decision consistency, reliability, and validity in the general clinical inpatient nurse population. This instrument will be useful in assessing pain management knowledge of clinical nurses to determine gaps in education, evaluate knowledge after pain management education, and measure research outcomes. Copyright © 2017 American Society for Pain Management Nursing. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Gao, Zhi-yu; Kang, Yu; Li, Yan-shuai; Meng, Chao; Pan, Tao
2018-04-01
Elevated-temperature flow behavior of a novel Ni-Cr-Mo-B ultra-heavy-plate steel was investigated by conducting hot compressive deformation tests on a Gleeble-3800 thermo-mechanical simulator at a temperature range of 1123 K–1423 K with a strain rate range from 0.01 s‑1 to10 s‑1 and a height reduction of 70%. Based on the experimental results, classic strain-compensated Arrhenius-type, a new revised strain-compensated Arrhenius-type and classic modified Johnson-Cook constitutive models were developed for predicting the high-temperature deformation behavior of the steel. The predictability of these models were comparatively evaluated in terms of statistical parameters including correlation coefficient (R), average absolute relative error (AARE), average root mean square error (RMSE), normalized mean bias error (NMBE) and relative error. The statistical results indicate that the new revised strain-compensated Arrhenius-type model could give prediction of elevated-temperature flow stress for the steel accurately under the entire process conditions. However, the predicted values by the classic modified Johnson-Cook model could not agree well with the experimental values, and the classic strain-compensated Arrhenius-type model could track the deformation behavior more accurately compared with the modified Johnson-Cook model, but less accurately with the new revised strain-compensated Arrhenius-type model. In addition, reasons of differences in predictability of these models were discussed in detail.
Real Revision: Authors' Strategies to Share with Student Writers
ERIC Educational Resources Information Center
Messner, Kate
2011-01-01
How do you show students that revision is more than a classroom exercise to please the teacher? Take them into the real world of writing for publication. In Real Revision, award-winning author and teacher Kate Messner demystifies the revision process for teachers and students alike and provides tried-and-true revision strategies, field tested by…
Pabinger, C; Berghold, A; Boehler, N; Labek, G
2013-02-01
To assess revision rates after knee arthroplasty by comparing the cumulative results from worldwide clinical studies and arthroplasty registers. We hypothesised that the revision rate of all clinical studies of a given implant and register data would not differ significantly. A systematic review of clinical studies in indexed peer-reviewed journals was performed followed by internal and external validation. Parameters for measurement of revision were applied (Revision for any reason, Revisions per 100 observed component years). Register data served as control group. Thirty-six knee arthroplasty systems were identified to meet the inclusion criteria: 21 total knee arthroplasty (TKA) systems, 14 unicondylar knee arthroplasty (UKA) systems, one patello-femoral implant system. For 13 systems (36%), no published study was available that contained revision data. For 17 implants (47%), publications were available dealing with radiographic, surgical or technical details, but power was too weak to compare revision rates at a significant level. Six implant systems (17%) had a significant number of revisions published and were finally analysed. In general, developers report better results than independent users. Studies from developers represent an overproportional share of all observed component years. Register data report overall 10-year revision rates of TKA of 6.2% (range: 4.9-7.8%), rates for UKA are 16.5% (range: 9.7-19.6%). Revision rates of all clinical studies of a given implant do not differ significantly from register data. However, significant differences were found between the revision rates published by developers and register data. Therefore the different data need to be interpreted in the context of the source of the information. Copyright © 2012 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cabble, Kevin J.; Boehlecke, Robert F.
This Closure Report (CR) presents information supporting the closure of Corrective Action Unit (CAU) 415: Project 57 No. 1 Plutonium Dispersion, which is located on Range 4808A of the Nevada Test and Training Range (NTTR). This CR complies with the requirements of the Federal Facility Agreement and Consent Order (FFACO) that was agreed to by the State of Nevada; U.S. Department of Energy (DOE), Environmental Management; U.S. Department of Defense; and DOE, Legacy Management. CAU 415 comprises one corrective action site (CAS): NAFR-23-02, Pu Contaminated Soil. The purpose of this CR is to provide justification and documentation supporting the recommendationmore » that no further corrective action is needed for CAU 415 based on the implementation of the corrective action of Closure in Place.« less
Thomsen, Per B; Jensen, Niels J F; Kampmann, Jens; Bæk Hansen, Torben
2013-01-01
During the last 25 years uncemented hip stem revision relying on diaphyseal fixation has shown improving clinical results and stem survival. The purpose of this study was to present the long-term results of hip revision with the SOLUTION stem (DePuy, Warsaw Indiana). Ninety-three consecutive SOLUTION hip stem revisions in 84 patients with a mean age of 69 years (range 33-86 years) were reviewed. Of these, clinical and radiographic follow-up examination by an independent observer was possible in 36 hips/29 patients after mean 14 years (range 10-18 years). Stem re-revision was documented by our own files and by the Danish Hip Arthroplasty Registry. Stem re-revision had been performed in two hips for aseptic loosening, one due to deep infection and in one patient due to stem fracture. The 18 years cumulative survival, free of re-revision for any reason was calculated as 94.4% (88.9-99.8)% and for aseptic loosening to 97.6% (94.3-100%). Intraoperative complications were frequent with incidence of shaft fractures (14/93) and perforations (9/93) showing a significant learning curve. Mean Harris Hip Score was 85 (range 53-99). Osseointegration was seen in 34/36 stems with two stems fibrous fixated. Stress shielding was significant associated with stem diameters ≥15 mm. Severe preoperative bone deficiency had no negative bearing on stem survival and no significant influence on osseointegration of the stem or on Harris Hip Score. Femoral stem revision with an extensively porous-coated monoblock chrome-cobalt stem seems to be a reliable and reproducible technique resulting in excellent long-term survivorship and clinical outcome. It can be used in femurs with deficient bone stock.
Batailler, C; Bonin, N; M Wettstein; Nogier, A; Martres, S; Ollier, E; May, O; Lustig, S
2017-12-01
Impingement of the ilio-psoas tendon on the acetabular component is a cause of pain after total hip arthroplasty (THA). Studies of cup revision for ilio-psoas impingement (IPI) are scarce and limited in size. We therefore conducted a large multicentre retrospective study with the following objectives: to assess the effectiveness of cup replacement in resolving the impingement syndrome, to determine the frequency and nature of complications after cup revision for IPI, and to identify pre-operative factors associated with good outcomes of cup revision for IPI. Cup revision is effective in resolving the pain due to IPI in selected patients. This retrospective multicentre study included 46 patients who underwent cup revision because of IPI. Before the revision, 38 (83%) patients had prominence of the anterior cup rim (mean, 9.9±4.5mm (range, 2-22mm) by radiography and 35 (76%) had cup malposition (anteversion<10° and/or inclination>50°). Mean follow-up was 21months (range, 6months to 6 years) and no patient was lost to follow-up. Outcomes at last follow-up were assessed based on the Oxford Hip Score (OHS), patient satisfaction index, complications, and revisions. At last follow-up, 39 (85%) patients were satisfied with the revision procedure, a significant improvement versus baseline was noted in the OHS (mean, 43±6; range, 25-48; P<0.001), and 41 patients were free of pain during hip flexion (P<0.001 versus baseline). Complications occurred in 3 (6.5%) patients, but only one complication was severe (deep infection). Recurrent groin pain was reported by 4 (8.7%) patients at last follow-up. None of the factors studied predicted the outcome of revision surgery. Cup revision for IPI after THA is effective in relieving the groin pain in 80% of patients with anterior cup rim prominence and/or cup malposition. However, complications can occur. Tenotomy may be preferable when the diagnosis is in doubt and/or cup position is acceptable. IV, retrospective observational study. Published by Elsevier Masson SAS.
Cancienne, Jourdan M; Brockmeier, Stephen F; Rodeo, Scott A; Werner, Brian C
2017-11-01
Recent animal studies have demonstrated that hyperlipidemia is associated with poor tendon-bone healing after rotator cuff repair; however, these findings have not been substantiated in human studies. To examine any association between hyperlipidemia and the failure of arthroscopic rotator cuff repair requiring revision surgery and to investigate whether the use of statin lipid-lowering agents had any influence on observed associations. Cohort study; Level of evidence, 3. From a national insurance database, patients who underwent arthroscopic rotator cuff repair with perioperative lipid levels (total cholesterol, low-density lipoprotein [LDL], and triglycerides) recorded were reviewed. For each lipid test, patients were stratified into normal, moderate, and high groups based on published standards. For the total cholesterol and LDL cohorts, a subgroup analysis of patients stratified by statin use was performed. The primary outcome measure was ipsilateral revision rotator cuff surgery, including revision repair or debridement. A logistic regression analysis controlling for patient demographics and comorbidities was utilized for comparison. There were 30,638 patients included in the study. The rate of revision rotator cuff surgery was significantly increased in patients with moderate (odds ratio [OR], 1.20; 95% CI, 1.03-1.40; P = .022) and high total cholesterol levels (OR, 1.36; 95% CI, 1.10-1.55; P = .006) compared with patients with normal total cholesterol levels perioperatively. Within each of these groups, patients without statin use had significantly higher rates of revision surgery, while those with statin prescriptions did not. The absolute risk reduction for statin use ranged from 0.24% to 1.87% when stratified by the total cholesterol level, yielding a number needed to treat from 54 to 408 patients. The rate of revision surgery was significantly increased in patients with moderate (OR, 1.24; 95% CI, 1.10-1.41; P = .001) and high LDL levels (OR, 1.46; 95% CI, 1.08-1.99; P = .014) compared with patients with normal LDL levels perioperatively. Again, patients without statin prescriptions had significantly increased rates of revision surgery, whereas patients with statin use did not. The absolute risk reduction for statin use ranged from 0.26% to 1.89% when stratified by the LDL level, yielding a number needed to treat from 53 to 387 patients. There were no significant differences in the rates of revision rotator cuff surgery between patients with moderate and high triglyceride levels compared with patients with normal triglyceride levels. The present study found a significant association between moderate and high perioperative total cholesterol and LDL levels and the rate of revision surgery after primary arthroscopic rotator cuff repair. Furthermore, the use of statin agents appeared to mitigate the need for revision rotator cuff repair. Further prospective studies are necessary to validate these preliminary findings and determine if better perioperative lipid control can improve clinical outcomes after arthroscopic rotator cuff repair.
Sakka, Laurent; Chomicki, Alexandre; Gabrillargues, Jean; Khalil, Toufic; Chazal, Jean; Avan, Paul
2016-02-01
Ventriculoperitoneal shunting is the first-line treatment for normal pressure hydrocephalus. Noninvasive auditory tests based on recorded otoacoustic emissions were assessed, as currently used for universal neonatal hearing screenings, for the diagnosis of cerebrospinal fluid shunt malfunction. The test was designed based on previous works, which demonstrated that an intracranial pressure change induces a proportional, characteristic, otoacoustic-emission phase shift. Forty-four patients with normal pressure hydrocephalus (23 idiopathic and 21 secondary cases) were included in this prospective observational study. The male:female sex ratio was 1.44, the age range was 21-87 years (mean age 64.3 years), and the range of the follow-up period was 1-3 years (mean 20 months). Patients were implanted with a Sophy SU8 adjustable-pressure valve as the ventriculoperitoneal shunt. The phase shifts of otoacoustic emissions in response to body tilt were measured preoperatively, immediately postoperatively, and at 3-6 months, 7-15 months, 16-24 months, and more than 24 months postoperatively. Three groups were enrolled: Group 1, 19 patients who required no valve opening-pressure adjustment; Group 2, 18 patients who required valve opening-pressure adjustments; and Group 3, 7 patients who required valve replacement. In Group 1, phase shift, which was positive before surgery, became steadily negative after surgery and during the follow-up. In Group 2, phase shift, which was positive before surgery, became negative immediately after surgery and increasingly negative after a decrease in the valve-opening pressure. In Group 3, phase shift was positive in 6 cases and slightly negative in 1 case before revision, but after revision phase shift became significantly negative in all cases. Otoacoustic emissions noninvasively reflect cerebrospinal fluid shunt function and are impacted by valve-opening pressure adjustments. Otoacoustic emissions consistently diagnosed shunt malfunction and predicted the need for surgical revision. The authors' diagnostic test, which can be repeated without risk or discomfort by an unskilled operator, may address the crucial need of detecting valve dysfunction in patients with poor clinical outcome after shunt surgery.
Matharu, Gulraj S; Pandit, Hemant G; Murray, David W
2017-02-01
High short-term failure rates have been reported for several metal-on-metal hip resurfacing (MoMHR) designs. Early observations suggested that MoMHRs revised to total hip arthroplasties (THAs) for pseudotumor had more major complications and inferior patient-reported outcomes compared with other revision indications. However, little is known about implant survivorship and patient-reported outcomes at more than 5 years after MoMHR revision. (1) What are the implant survivorship, proportion of complications and abnormal radiological findings, and patient-reported outcomes at a median of 10 years after MoMHR revision surgery? (2) Are survivorship, complications, and patient-reported outcomes influenced by revision indication? (3) Do any other factors predict survivorship, complications, and patient-reported outcomes? Between 1999 and 2008, 53 MoMHR revision procedures in 51 patients (mean age, 55 years; 62% female) were performed at one center and were all included in this retrospective study. Two patients (4%) were lost to followup and two patients (4%) died before a minimum followup of 7 years (median, 10.3 years; range 7-15 years). Revision indications included pseudotumor (n = 16), femoral neck fracture (n = 21), and other causes (n = 16). In most cases (62%, n = 33) both components were revised to a non-MoM bearing THA with the remainder (38%, n = 20: fracture, loosening, or head collapse) undergoing femoral-only revision to a large-diameter MoM THA. Postrevision complications, rerevision, Oxford Hip Score (OHS), and UCLA score were determined using both a longitudinally maintained institutional database and postal questionnaire. Implant survivorship was assessed using the Kaplan-Meier method (endpoint was rerevision surgery). Radiographs at latest followup were systematically assessed for any signs of failure (loosening, migration, osteolysis) by one observer blinded to all clinical information and not involved in the revision procedures. Overall, 45% (24 of 53) experienced complications and 38% (20 of 53) underwent rerevision. Ten-year survival free from rerevision for revised MoMHRs was 63% (95% confidence interval [CI], 48%-74%). Revision indications were not associated with differences in the frequency of complications or repeat revisions. With the numbers available, 10-year survival free from rerevision for pseudotumor revisions (56%; 95% CI, 30%-76%) was not different from the fracture (68%; 95% CI, 42%-85%; p = 0.359) and other groups (63%; 95% CI, 35%-81%; p = 0.478). Pseudotumor revisions had inferior OHSs (median, 21; range, 2-46; p = 0.007) and UCLA scores (median, 2; range, 2-7; p = 0.0184) compared with fracture and other revisions. Ten-year survival free from rerevision after femoral-only revision using another large-diameter MoM bearing was lower (p = 0.0498) compared with all component revisions using non-MoM bearings. After controlling for potential confounding variables such as age, sex, and revision indication, we found femoral-only revision as the only factor predicting rerevision (hazard ratio, 5.7; 95% CI, 1.1-29; p = 0.040). Poor implant survivorship and frequent complications were observed at a median of 10 years after MoMHR revision. However, patients undergoing femoral-only revisions with large-diameter MoM bearings had the worst survivorship, whereas patients revised for pseudotumor had the most inferior patient-reported outcomes. Our findings suggest these two patient subgroups require regular surveillance after MoMHR revision. Level III, therapeutic study.
Age Effects on Wechsler Adult Intelligence Scale-Revised Tests.
ERIC Educational Resources Information Center
Sattler, Jerome M.
1982-01-01
Studied age norms for 11 individual Wechsler Adult Intelligence Scale-Revised (WAIS-R) tests. Digit Symbol showed the most decline. Results suggest that fluid intelligence, as measured by the performance scale tests, shows more of a decline with age than crystallized intelligence, as measured by the verbal scale tests. (Author)
Carvalho, Lucas de Francisco; Sette, Catarina Possenti; Ferrari, Bárbara Letícia
2016-01-01
Personality disorders are among the most common disorders seen in clinical psychology. However, in Brazil there are few instruments for assessing the pathological characteristics of personality. To revise the grandiosity dimension of the Brazilian Dimensional Clinical Personality Inventory (Inventário Dimensional Clínico da Personalidade [IDCP]) and investigate its psychometric properties. A total of 225 people participated in this study. Their ages ranged from 18 to 66 years (mean [M] = 26.2, standard deviation [SD] = 8.1) and the majority were female (n = 162, 70.1%). The IDCP and the Brazilian versions of the Revised NEO Personality Inventory (NEO PI-R) and the Personality Inventory for DSM-5 (PID-5) were administered to all participants. A total of 285 new items were developed and content analysis was used to select 33 of these to comprise the final version destined for administration. The results of parallel analysis and factor analysis identified four interpretable factors. Internal consistency coefficients were deemed acceptable and varied from 0.73 to 0.84 for the factors. Additionally, the expected correlations between the IDCP Inventory and the other tests were observed. This study demonstrates the revised dimension's suitability for assessment of the pathological traits of narcissistic personality disorder.
Hameed, Mustafa Q; Zurakowski, David; Proctor, Mark R; Stone, Scellig S D; Warf, Benjamin C; Smith, Edward R; Goumnerova, Liliana C; Swoboda, Marek; Anor, Tomer; Madsen, Joseph R
2018-06-16
While a noninvasive flow determination would be desirable in the diagnosis of cerebrospinal fluid shunt malfunction, existing studies have not yet defined a role for thermal flow detection. To evaluate a revised test protocol using a micropumper designed to transiently enhance flow during thermal testing to determine whether thermal detection of flow is associated with progression to shunt revision surgery. Eighty-two unique tests were performed in 71 shunts. The primary outcome, need for revision within 7 d of testing, was compared with results of micropumper-augmented thermal flow detection. Statistical analysis was based on blind interpretation of test results and raw temperature data recorded during testing. The test was sensitive (73%) and specific (68%) in predicting need for revision, with 5.6-fold higher probability of revision when flow was not detected. Negative predictive value in our sample was 94.2%. The probability of not requiring revision increased with increasing total temperature drop. Analysis of various possible thresholds showed that the optimal temperature cutoff may be lower than suggested by the manufacturer (0.125°C vs 0.2°C). This is the first study to report a strong association between thermal flow evaluation and a clinical impression that a shunt is not malfunctioning. The current recommended threshold may increase the false positive rate unnecessarily, and as clinicians gain experience with the method, they may find value in examining the temperature curves themselves. Multicenter studies are suggested to further define a role for this diagnostic test.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-10
... Promulgation of Air Quality Implementation Plans; Colorado; Revisions to Regulation Number 1 AGENCY... Number 1 (revisions to the performance testing requirements for air curtain destructors). Colorado... concurrent with Colorado's Regulation Number 1 revision request will be acted on at a later date. In the...
Progress towards extreme attitude testing with Magnetic Suspension and Balance Systems
NASA Technical Reports Server (NTRS)
Britcher, Colin P.; Parker, David H.
1988-01-01
Progress is reported in a research effort aimed towards demonstration of the feasibility of suspension and aerodynamic testing of models at high angles of attack in wind tunnel Magnetic Suspension and Balance Systems. Extensive modifications, described in this paper, have been made to the Southampton University suspension system in order to facilitate this work. They include revision of electromagnet configuration, installation of all-new position sensors and expansion of control system programs. An angle of attack range of 0 to 90 deg is expected for axisymmetric models. To date, suspension up to 80 deg angle of attack has been achieved.
78 FR 67206 - Qualification Tests for Safety-Related Actuators in Nuclear Power Plants
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-08
... NUCLEAR REGULATORY COMMISSION [NRC-2013-0079] Qualification Tests for Safety-Related Actuators in..., ``Qualification Tests for Safety-Related Actuators in Nuclear Power Plants.'' This RG is being revised to provide... power plants. This RG is proposed Revision 1 of RG 1.73, ``Qualification Tests of Electric Valve...
Revision of OECD Guidelines for Genotoxicity Testing: Current Status and Next Steps
Over the past 30 years, assays have been developed to evaluate chemical genotoxicity. OECD Genotoxicity Test Guidelines (TG) describe assay procedures for regulatory safety testing. Since the last OECD TG revision (1997), there has been tremendous scientific and technological pro...
Moderate clinical improvement after revision arthroplasty of the severely stiff knee.
Heesterbeek, P J C; Goosen, J H M; Schimmel, J J P; Defoort, K C; van Hellemondt, G G; Wymenga, A B
2016-10-01
Revision of the severe stiff total knee arthroplasty (TKA) is challenging, and clinical outcome is inferior to other indications for revision. The purpose of the present study was to determine clinical outcome of TKA revision in patients with severe stiffness (range of motion (ROM) ≤ 70°) and evaluate a possible influence of accompanying findings, such as component malposition, aseptic loosening or instability. A prospective cohort of 40 patients with a preoperative ROM ≤ 70° and a minimum of 2-year follow-up after total system revision (Genesis or Legion stemmed condylar implant) was evaluated. ROM, Knee Society Scoring System (KSS) and visual analogue scale (VAS) pain scores were obtained preoperatively and at 2 years. Patient satisfaction and complication rate were assessed. Component malposition was most frequently reported as accompanying finding (n = 27). Comparisons between pre- and postoperative outcome (p < 0.05) and between different subgroups (component malposition, aseptic loosening, and instability) based on accompanying findings were made (no statistical comparison). ROM, KSS and VAS pain scores improved significantly (p < 0.001): median ROM at two years 85° (range 10-125) and median gain 25° (range -10 to +85). Median VAS satisfaction was 53.5 points (range 15-98). Seventeen patients reported at least one complication, including one re-revision. Six patients underwent manipulation under anaesthesia, and five were referred to the pain clinic. No clear differences between subgroups were observed. TKA revision in patients with severe stiffness resulted in a moderate but significant improved clinical outcome after 2 years. Accompanying abnormalities such as component malposition, aseptic loosening or instability did not influence clinical outcome. Realistic patient counselling on the moderate outcome and possible remaining limitations in daily life might help to improve patient satisfaction. Therapeutic studies-case series with no comparison group, Level IV.
Hernandez, Nicholas M; Chalmers, Brian P; Wagner, Eric R; Sperling, John W; Cofield, Robert H; Sanchez-Sotelo, Joaquin
2017-11-01
Instability after shoulder arthroplasty remains a complication with limited salvage options. Reoperation for instability with anatomic designs has led to high rates of persistent instability, therefore we aimed to evaluate the use of RSA for treatment of prosthetic instability. (1) After revision shoulder arthroplasty to a reverse prosthesis (RSA), what is the survivorship free from dislocations at 2 and 5 years? (2) What factors are associated with dislocations? (3) What is the survivorship free from revision after revision to RSA? (4) From preoperation to postrevision to RSA, what are the clinical outcomes-the proportion of patients with moderate to severe pain, shoulder elevation and external rotation ROM, American Shoulder and Elbow Surgeons scores, and Simple Shoulder Test scores? All shoulder arthroplasties revised for prosthetic instability using RSA components between January 2004 and July 2014 were retrospectively studied. During the period in question, we performed 82 revisions for instability of an anatomic total shoulder arthroplasty (TSA) (n = 62), hemiarthroplasty (n = 13), or reverse TSA (n = 7). We typically used a reverse TSA to treat this problem, but we identified 12 treated in other ways, including revision of a TSA to hemiarthroplasty (n = 3), revision of a reverse TSA to hemiarthroplasty (n = 2), revision of hemiarthroplasty to a hemiarthroplasty (n = 1), and revision of an anatomic TSA to another anatomic TSA (n = 6). This left 70 patients for evaluation; of those, 65 (93%) were available for analysis at a mean of 3 years (range, 2-10 years). A total of seven patients died. Eight of the 65 shoulders were not evaluated during the last 5 years, including three in patients who died earlier. The mean age of the patients at the time of revision RSA was 65 years (range, 40-89 years). Data were obtained from a longitudinally maintained institutional joint registry. Instability was defined as severe subluxation confirmed on clinical and radiographic examinations. We evaluated pain and ROM, and Kaplan-Meier curves were used to estimate survivorship. The survivorship free from dislocation at 2 and 5 years was 87% (95% CI, 80%-94%) and 79% (95% CI, 67%-91%) respectively, with 10 of 65 (15%) patients having an episode of dislocation after revision surgery. Persistent instability was more common in those with a BMI greater than 35 kg/m 2 (hazard ratio [HR], 5; 95% CI, 2-16; p = 0.008) and prior hemiarthroplasty (HR, 5; 95% CI, 2-16; p = 0.005), whereas patients who had undergone a previous TSA were less likely to have persistent instability (HR, 0.08; 95% CI, 0.0-0.30; p < 0.001) The survival free from rerevision for any indication at 2 and 5 years was 85% (95% CI, 76%-94%) and 78% (95% CI, 66%-90%) respectively; with the numbers available, we were not able to find associated factors. Fewer patients had moderate or severe pain after revision to RSA (preoperative: 48 of 65 [74%]; postoperative: nine of 65 [14%]; p < 0.001). After surgery, patients showed improvement in shoulder elevation (preoperative: 42° [± 30°], postoperative: 112° [42°]; mean difference, 70° [95% CI, - 83 o to 57°]; p < 0.001) and external rotation (preoperative: 20° [± 22°], postoperative: 42° [± 23°]; mean difference, 22° [95% CI, - 30° to - 14°]; p < 0.001). American Shoulder and Elbow Surgeons scores improved (preoperative: 21 [± 10], postoperative: 68 [± 14], mean difference, 46 [95% CI, - 58 to - 35]; p < 0.001); where a higher score is better. Simple Shoulder Test scores also improved (preoperative: 2/12 [± 2], postoperative: 7/12 [± 3]; mean difference, 5 [95% CI, - 7 to - 2.17]; p < 0.001); where a higher score is better. Revision RSA for prosthetic instability after shoulder arthroplasty is associated with reasonable implant survival and few complications. Approximately one in seven patients will have a recurrent dislocation. In patients with persistent instability or with risk factors for instability, consideration should be given for use of larger glenospheres and increasing the lateral offset at the time of RSA. Level IV, therapeutic study.
Migaud, Henri; Putman, Sophie; Kern, Grégory; Isida, Ronald; Girard, Julien; Ramdane, Nassima; Delaunay, Christian P; Hamadouche, Moussa
2016-10-01
Despite widespread use of ceramic-on-ceramic (CoC) in total hip arthroplasty (THA) during the past 10 years, little is known about why revisions are performed in hips with this bearing or the time elapsed before revision. The purposes of this study were: (1) Do the reasons for first revision differ between CoC bearings and other bearing couples? (2) Does the time to revision differ between CoC and other bearing couples? (3) Are there unique reasons for revisions of CoC bearings? All members of the Société Française de Chirurgie Orthopédique et Traumatologique (SoFCOT) who performed ≥ 30 revisions per year were invited to participate in this multicenter, prospective, observational study. Our data represent 12% of the revision procedures performed in France. A total of 2107 first revisions of THA (from January 2010 to December 2011) were done in 2107 patients (1201 females [57%] and 906 males [43%]; median age, 73 years; age range, 17-104 years) at the time of surgery after a median of 11 years (range, 0 day-42 years) after the primary THA. There were 238 of 2107 (11%) CoC, 148 of 2107 (7%) metal-on-metal (MoM), and 1721 of 2017 (82%) metal-on-polyethylene (MoP) bearings. The reasons for reoperation differed according to the bearing component: (1) for the MoP reference bearing (odds ratio [OR]; 95% confidence interval), cup loosening occurred in 698 of 1721 hips (41%), periprosthetic fracture in 220 of 1721 hips (13%), and osteolysis in 213 of 1721 hips (12%); (2) for CoC, cup loosening occurred in 41 of 238 hips (17%) (OR, 0.31 [0.22-0.43; p < 0.001), infection in 39 of 238 hips (16%) (OR, 1.63 [1.12-2.37]; p = 0.01), and dislocation in 23 of 238 hips (10%) (OR, 0.9 [0.57-1.42]; p = 0.9); (3) for MoM, cup loosening occurred in 28 of 148 hips (19%) (OR, 0.34 [0.22-0.52]; p < 0.001), adverse reaction to metallic debris in 26 of 148 hips (18%) (OR, 18.12 [9.84-33.4]; p < 0.001), and infection in 16 of 148 hips (11%) (OR, 1 [0.59-1.73]; p = 0.9). In comparison with MoP, osteolysis was rarely the reason for revision in CoC (four of 238 hips [2%]; OR, 0.12 [0.05-0.33]; p < 0.001), but this bearing was frequently revised because of iliopsoas irritation (18 of 238 hips [8%]; OR, 4.9 [2.7-9]; p < 0.001). The time elapsed before revision differed between bearings: median of 3 years (range, 3 days to 28 years) for CoC and 4 years (range, 14 days to 37 years) for MoM versus a median 13 years (range, 0 day to 42 years) for MoP (p < 0.001). Thirty-seven of the 238 revisions (16%) were directly related to ceramic use (ceramic breakage [n = 23], squeaking [n = 6], impingement [n = 7], incorrect ceramic insert insertion [n = 1]). No factors were identified that contributed to breakage of the 12 bulk ceramic components (eight heads, four inserts, four of 12 Delta ceramic). No factors were associated with squeaking, iliopsoas irritation, or impingement, but component orientation was not assessed. The reasons and time to first revision differed between CoC and other bearings. CoC THAs are revised earlier and are sensitive to mechanical problems such as impingement, squeaking, and ceramic rupture that did not disappear with introduction of Delta ceramics and large-diameter (≥ 36 mm) bearings. CoC was rarely revised for osteolysis, but a high rate of iliopsoas irritation requires further investigation. Level III, therapeutic study.
Task 2 - Limits for High-Frequency Conducted Susceptibility Testing - CS114 (NRC-HQ-60-14-D-0015)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wood, Richard Thomas; Ewing, Paul D.; Moses, Rebecca J.
2015-09-01
A principal focus of Task 2 under this project was for ORNL to evaluate the basis for susceptibility testing against high-frequency conducted interference and to establish recommendations to resolve concerns about the severity of test limits for the conducted susceptibility (CS) test, CS114, from MIL-STD-461. The primary concern about the test limit has been characterized by the EPRI EMI Working Group in the following terms: Demonstrating compliance with the CS114 test limits recommended in TR-102323 has proven to be problematic, even for components that have been tested to commercial standards and demonstrated proper operation in industrial applications [6]. Specifically, EPRImore » notes that the CS114 limits approved in regulatory documents are significantly higher than those invoked by the US military and similar commercial standards in the frequency range below 200 kHz. For this task, ORNL evaluated the original approach to establishing the test limit, EPRI technical findings from a review of the limit, and the regulatory basis through which the currently approved limits were accepted. Based on this analysis, strategies have been developed regarding changes to the CS114 limit that can resolve the technical concerns raised by the industry. Guided by the principles that reasonable assurance of safety must not be compromised but excessive conservatism should be reduced, recommendations on a suitable basis for a revised limit have been developed and can be incorporated into the planned Revision 2 of RG 1.180.« less
Using a Bedside Video-assisted Test Tube Test to Assess Stoma Viability: A Report of 4 Cases.
Ahmad, Sarwat; Turner, Keli; Shah, Paulesh; Diaz, Jose
2016-07-01
Mucosal discoloration of an intestinal stoma may indicate self-limited venous congestion or necrosis necessitating operative revision. A common bedside technique to assess stoma viability is the "test tube test". A clear tube is inserted into the stoma and a hand-held light is used to assess the color of the stoma. A technique (video-assisted test tube test [VATTT]) developed by the authors utilizes a standard video bronchoscope inserted into a clear plastic blood collection tube to visually inspect and assess the mucosa. This technique was evaluated in 4 patients (age range 49-72 years, all critically ill) with a discolored stoma after emergency surgery. In each case, physical exam revealed ischemic mucosa at the surface either immediately after surgery or after worsening hypotension weeks later. Serial test tube test assessments were ambiguous when trying to assess deeper mucosa. The VATTT assessment showed viable pink mucosa beneath the surface and until the fascia was revealed in 3 patients. One (1) patient had mucosal ischemia down to the fascia, which prompted operative revision of the stoma. The new stoma was assessed with a VATTT and was viable for the entire length of the stoma. VATTT provided an enhanced, magnified, and clearer way to visually assess stoma viability in the postoperative period that can be performed at the bedside with no adverse events. It may prevent unnecessary relaparotomy or enable earlier diagnosis of deep ostomy necrosis. Validity and reliability studies are warranted.
AAHPER Youth Fitness Test Manual. Revised Edition.
ERIC Educational Resources Information Center
American Alliance for Health, Physical Education, and Recreation, Washington, DC.
The Revised AAHPER Youth Fitness Test is a battery of six test items designed to give a measure of physical fitness for boys and girls in grades 5-12. The tests were selected to evaluate specific aspects of physical status which, taken together, give an overall picture of fitness. Tests can be given in the gymnasium or outdoors. They are as…
Galindo, Carla A; Few, Tai E; Daniels, Brandy; Parks, Carolyn P; Diallo, Dázon D; Moss, L Nyrobi N; Wilkes, Aisha L; Carraway, G Chezia
2017-05-01
Healthy Love is a brief, highly interactive, single-session, group-level HIV prevention intervention designed for African American women that is effective at reducing sex risk behaviors and increasing condom use and HIV testing among participants. The Centers for Disease Control and Prevention, through a contract, developed a user-friendly intervention package that would allow organizations to adopt and implement Healthy Love with fidelity. Training and implementation materials were developed to support original research protocols, and piloted and revised to conduct field-testing with case study agencies (CSAs). Three CSAs were selected to deliver the intervention over a 3-month period to test the utility of intervention materials and feasibility of implementation. All CSAs were able to successfully deliver 10 sessions with a total of 185 women ranging from 18 to 59 years of age. Successes and challenges encountered in training, preimplementation activities, and intervention delivery are described. Lessons learned from training, technical assistance, and process monitoring and evaluation informed final package revisions. Research to practice recommendations are shared as is guidance for future implementations of Healthy Love. The research to practice process used is a model approach for developing a comprehensive intervention package and will support the adoption of Healthy Love by other organizations.
Plume interference with space shuttle range safety signals
NASA Technical Reports Server (NTRS)
Boynton, F. P.; Rajaseknar, P. S.
1979-01-01
The computational procedure for signal propagation in the presence of an exhaust plume is presented. Comparisons with well-known analytic diffraction solutions indicate that accuracy suffers when mesh spacing is inadequate to resolve the first unobstructed Fresnel zone at the plume edge. Revisions to the procedure to improve its accuracy without requiring very large arrays are discussed. Comparisons to field measurements during a shuttle solid rocket motor (SRM) test firing suggest that the plume is sharper edged than one would expect on the basis of time averaged electron density calculations. The effects, both of revisions to the computational procedure and of allowing for a sharper plume edge, are to raise the signal level near tail aspect. The attenuation levels then predicted are still high enough to be of concern near SRM burnout for northerly launches of the space shuttle.
Unicondylar arthroplasty in knees with deficient anterior cruciate ligaments.
Engh, Gerard A; Ammeen, Deborah J
2014-01-01
Historically, a functional ACL has been a prerequisite for patients undergoing unicondylar knee arthroplasty (UKA). However, this premise has not been rigorously tested. We compared (1) the survivorship free from revision and (2) the failure mechanisms of UKAs in ACL-deficient knees and UKAs in ACL-intact knees performed over the same time interval. Between November 2000 and July 2008, a fixed bearing UKA was performed in 72 patients (81 knees) with intraoperatively confirmed ACL deficiency. Five patients (five knees) with preoperative instability underwent ACL reconstruction and were excluded from analysis. Of the remaining 67 patients (76 knees) without preoperative instability, implant status was known for 68 UKAs in 60 patients. Survivorship and failure mechanisms for these knees were compared to those of 706 UKAs in ACL-intact knees performed during the same time interval by the same surgeon using the same implant system. Minimum followup for the ACL-deficient group was 2.9 years (mean, 6 years; range, 2.9-10 years). Revision rates between UKAs with and without intact ACLs were similar in the absence of clinical instability (p = 0.58). Six-year UKA survivorship was 94% (95% CI: 88%-100%) in ACL-deficient knees and 93% (95% CI: 91%-96%) in ACL-intact knees (p = 0.89). Five knees (7%) in the ACL-deficient group were revised: disease progression (two), loose tibia (one), persistent pain (one), and revised elsewhere/reason unknown (one). Thirty-six knees in the ACL-intact group underwent revision (5%): aseptic loosening (13), revised elsewhere/reason unknown (11), disease progression (three), tibial subsidence/fracture (four), infection (three), pain (one), and lateral compartment overload (one). At 6 years, deficiency of the ACL in patients without clinical knee instability did not impact the survivorship of UKAs compared to UKAs performed in knees with intact ACLs.
Periprosthetic Joint Infection of Shoulder Arthroplasties: Diagnostic and Treatment Options
Sevelda, Florian
2017-01-01
Periprosthetic joint infection (PJI) is one of the most frequent reasons for painful shoulder arthroplasties and revision surgery of shoulder arthroplasties. Cutibacterium acnes (Propionibacterium acnes) is one of the microorganisms that most often causes the infection. However, this slow growing microorganism is difficult to detect. This paper presents an overview of different diagnostic test to detect a periprosthetic shoulder infection. This includes nonspecific diagnostic tests and specific tests (with identifying the responsible microorganism). The aspiration can combine different specific and nonspecific tests. In dry aspiration and suspected joint infection, we recommend a biopsy. Several therapeutic options exist for the treatment of PJI of shoulder arthroplasties. In acute infections, the options include leaving the implant in place with open debridement, septic irrigation with antibacterial fluids like octenidine or polyhexanide solution, and exchange of all removable components. In late infections (more than four weeks after implantation) the therapeutic options are a permanent spacer, single-stage revision, and two-stage revision with a temporary spacer. The functional results are best after single-stage revisions with a success rate similar to two-stage revisions. For single-stage revisions, the microorganism should be known preoperatively so that specific antibiotics can be mixed into the cement for implantation of the new prosthesis and specific systemic antibiotic therapy can be applied to support the surgery. PMID:29423407
Baghdadi, Yaser M K; Morrey, Bernard F; O'Driscoll, Shawn W; Steinmann, Scott P; Sanchez-Sotelo, Joaquin
2014-07-01
Primary reconstruction of the lateral collateral ligament complex (LCLC) using graft tissue restores elbow stability in many, but not all, elbows with acute or chronic posterolateral rotatory instability (PLRI). Revision reconstruction using a tendon allograft is occasionally considered for persistent PLRI, but the outcome of revision ligament reconstruction in this setting is largely unknown. We determined whether revision allograft ligament reconstruction can (1) restore the stability and (2) result in improved elbow scores for patients with persistent PLRI of the elbow after a previous failed primary reconstructive attempt and in the context of the diverse pathology being addressed. Between 2001 and 2011, 160 surgical elbow procedures were performed at our institution for the LCLC reconstruction using allograft tissue. Only patients undergoing revision allograft reconstruction of the LCLC for persistent PLRI with a previous failed primary reconstructive attempt using graft tissue and at least I year of followup were included in the study. Eleven patients (11 elbows) fulfilled our inclusion criteria and formed our study cohort. The cohort consisted of six female patients and five male patients. The mean age at the time of revision surgery was 36 years (range, 14-59 years). The revision allograft reconstruction was carried out after a mean of 3 years (range, 2.5 months to 9 years) from a failed attempted reconstruction of the LCLC. Osseous deficiency to some extent was identified in the preoperative radiographs of eight elbows. Mean followup was 5 years (range, 1-12 years). Revision allograft reconstruction of the LCLC restored elbow stability in eight of the 11 elbows; two of the three elbows with persistent instability were operated on a third time (at 6 and 7 months after allograft revision reconstruction). For elbows with no persistent instability, the mean Mayo Elbow Performance Score at most recent followup was 83 points (range, 60-100 points), and six elbows were rated with a good or excellent result. All patients with persistent instability had some degree of preoperative bone loss. Revision allograft reconstruction of the LCLC is an option for treating recurrent PLRI, although this is a complex and resistant problem, and nearly ½ of the patients in this cohort either had persistent instability and/or had a fair or poor elbow score. Level IV, therapeutic study. See Instructions for Authors for a complete description of levels of evidence.
Stier, Christine; Chiappetta, Sonja
2016-08-01
Dumping syndrome is a long-term postoperative complication of Roux-en-Y gastric bypass procedures. Morphologically, dumping syndrome usually correlates with a dilatation of the gastroenterostomy with accelerated pouch emptying. Conservative therapy includes diet changes, complementary pharmacotherapy and, if symptoms persist, surgical revision. Surgical options include endoscopic, endoluminal surgery to constrict the gastrojejunostomy using a novel endoscopic suturing device (OverStitch(TM), Apollo). In our study, we aimed to assess the viability, safety and efficacy of this procedure in patients with late dumping; 14 patients who had developed late dumping syndrome underwent surgery using an endoscopic suturing technique (OverStitch(TM), Apollo). Late dumping was confirmed by Sigstad score and an oral glucose tolerance test (OGTT). Prior to surgery, objective analysis of pouch emptying speed was assessed by gastric scintigraphy. Surgery was performed under general anaesthesia. None of the 14 patients suffered intra- or postoperative complications. No postsurgical increase in inflammation parameters was observed. The postinterventional pain scale (visual analogue scale) showed a mean score of 0.5 (range 0-10). In 13 of the 14 patients, no dumping was observed 1-month postsurgery. The postoperative Sigstad score (3.07 ± 2.06; range 1-9) showed an impressive reduction compared with the preoperative score (12.71 ± 4.18; range 7-24) (p < 0.001). Postoperative upper gastrointestinal gastrografin swallow revealed regular emptying in all the patients. The endoluminal endoscopic suturing technique-applied here for surgical revision of gastroenterostomy following Roux-en-Y gastric bypass-represents a promising, novel therapeutic option in late dumping syndrome involving minimal trauma and offering rapid reconvalescence.
[Progress in assays for and new developments in autoimmune pathophysioirmen's introductory remarks].
Miyazawa, Yukihisa; Shimadu, Chisato; Ohi, Kayoko
2005-11-01
We examined the influence of a revision of health insurance in 2004 in Teikyo University Hospital in comparison with 2003. Out to the returns of most hematological tests, especially HbA1c and TK, being included in the treatment charges of outpatients, gross laboratory test sales decreased more than expected. Increased income from judgment charges and management charges could not make up for the deficit in test sales. Therefore, total laboratory test revenues decreased substantially. In 2006, the new revision of health insurance will worsen the revenues further. Hospital laboratory test departments should take appropriate and aggressive management steps in response to these revisions in health insurance.
Factor Structure of the Revised TOEIC[R] Test: A Multiple-Sample Analysis
ERIC Educational Resources Information Center
In'nami, Yo; Koizumi, Rie
2012-01-01
This study examined the factor structure of the listening and reading sections of the revised Test of English for International Communication (TOEIC[R]) test. The data from the TOEIC IP (institutional program) test taken by 569 English learners were randomly split into two samples (n = 285 vs. 284). Four models (higher-order, correlated,…
Instrument Pilot: Airplane. Flight Test Guide, Part 61 Revised 1973, AC 61-56.
ERIC Educational Resources Information Center
Federal Aviation Administration (DOT), Washington, DC. Flight Standards Service.
This flight test guide is designed to assist the applicant and his instructor in preparing for the flight test for Instrument Pilot Airplane Rating under Part 61 (revised) of Federal Aviation Regulations. It contains information concerning pilot operations, procedures, and maneuvers relevant to the flight test required for the Instrument Rating.…
Using Knowledge Management to Revise Software-Testing Processes
ERIC Educational Resources Information Center
Nogeste, Kersti; Walker, Derek H. T.
2006-01-01
Purpose: This paper aims to use a knowledge management (KM) approach to effectively revise a utility retailer's software testing process. This paper presents a case study of how the utility organisation's customer services IT production support group improved their test planning skills through applying the American Productivity and Quality Center…
Flight Test Guide (Part 61 Revised): Instrument Pilot: Helicopter.
ERIC Educational Resources Information Center
Federal Aviation Administration (DOT), Washington, DC. Flight Standards Service.
The guide provides an outline of the skills required to pass the flight test for an Instrument Pilot Helicopter Rating under Part 61 (revised) of Federal Aviation Regulations. General procedures for flight tests are described and the following pilot operations outlined: maneuvering by reference to instruments, IFR navigation, instrument…
ERIC Educational Resources Information Center
Ramirez, Arnulfo G.; Politzer, Robert L.
A revised Spanish/English oral-proficiency test battery was administered to 40 Spanish-surnamed pupils equally divided by sex at grade levels 1, 3, 5, and 7. The test battery included parallel Spanish and English versions of: (1) a 12-item vocabulary pretest, (2) a 32-item vocabulary-by-domain test consisting of four sections--home, neighborhood,…
ERIC Educational Resources Information Center
Bolen, L. M.; Kimball, D. J.; Hall, C. W.; Webster, R. E.
1997-01-01
Compares the visual and auditory processing factors of the Woodcock Johnson Tests of Cognitive Ability, Revised (WJR COG) and the visual and auditory memory factors of the Learning Efficiency Test, II (LET-II) among 120 college students. Results indicate two significant performance differences between the WJR COG and LET-II. (RJM)
ERIC Educational Resources Information Center
Ott, Lauren M.
2010-01-01
This study compared the reading subtests of the Wechsler Individual Achievement Test-Third Edition and the Peabody Individual Achievement Test-Revised/Normative Update. Scores were compared on these two tests in a group of 28 students ages 7 through 12 who were referred or reevaluated for suspected learning problems. The data were collected…
Can, Ata; Erdogan, Fahri; Erdogan, Ayse Ovul
2017-09-01
Tibiofemoral instability is a common complication after total knee arthroplasty (TKA), accounting for up to 22% of all revision procedures. Instability is the second most common cause of revision in the first 5 years after primary TKA. In this study, 13 knees with tibiofemoral instability after TKA were identified among 693 consecutive primary TKA procedures. Patient demographics, body mass index, clinical symptoms, previous deformity, previous knee surgery, complications, interval between index TKA and first tibiofemoral instability, causes of instability, and interval between index TKA and revision TKA were retrospectively reviewed. Clinical outcomes were assessed with the Lysholm Knee Scoring Scale. All patients were women, and mean body mass index was 37.7 kg/m 2 (range, 27.2-52.6 kg/m 2 ). Mean interval between index TKA and first tibiofemoral instability was 23.4 months (range, 9-45 months), and mean interval between index TKA and revision TKA was 25.6 months (range, 14-48 months). All patients had posterior cruciate ligament-retaining implants. Of the 13 knees, 11 had flexion instability and 2 had global instability. In all patients, instability was caused by incompetence of the posterior cruciate ligament; additionally, 1 patient had undersized and malpositioned implants. In 4 knees, the polyethylene insert was broken as well. All patients underwent revision TKA. Lysholm Knee Scoring Scale score had improved from a mean of 35.8 (range, 30-46) to a mean of 68.3 (range, 66-76). All patients included in this study were female and obese. The main cause of instability was secondary posterior cruciate ligament rupture and incompetence. The use of posterior-stabilized implants for primary TKA may prevent secondary instability in obese patients. [Orthopedics. 2017; 40(5):e812-e819.]. Copyright 2017, SLACK Incorporated.
M-52 spray booth qualification test
NASA Technical Reports Server (NTRS)
1990-01-01
The procedures, performance, and results obtained from the M-52 spray booth qualification test are documented. The test was conducted at Thiokol Corporation, Space Operations, M-52 Inert Parts Preparation facility. The purpose of this testing sequence was to ensure the spray booth would produce flight qualified hardware. The testing sequence was conducted in two series. The first series was conducted under CTP-0142, Revision 1. The second series was conducted in accordance with CTP-0142, Revision 2. The test sequence started with CTP-0142, Revision 1. The series consisted of the contamination removal test and the performance test. The contamination removal test was used to assess the Teflon level in the spray booth. The performance test consisted of painting and Chemloking a forward dome inside the spray booth per flight procedures. During the performance test, two sets of witness panels (case/insulation and steel/epoxy/steel) were prepared and pull tested. The CTP-0142, Revision 2, series of testing consisted of re-testing the steel/epoxy/steel witness panels. The pull tests analysis indicates the results of the tensile tests were comparable to the systems tunnel witness panel database. The exposed panel set and the control panel set average tensile values were above the 1-basis lower limits established on the systems tunnel witness panel database. It is recommended that the M-52 spray booth be qualified for producing flight hardware.
Answering the call: a tool that measures functional breast cancer literacy.
Williams, Karen Patricia; Templin, Thomas N; Hines, Resche D
2013-01-01
There is a need for health care providers and health care educators to ensure that the messages they communicate are understood. The purpose of this research was to test the reliability and validity, in a culturally diverse sample of women, of a revised Breast Cancer Literacy Assessment Tool (Breast-CLAT) designed to measure functional understanding of breast cancer in English, Spanish, and Arabic. Community health workers verbally administered the 35-item Breast-CLAT to 543 Black, Latina, and Arab American women. A confirmatory factor analysis using a 2-parameter item response theory model was used to test the proposed 3-factor Breast-CLAT (awareness, screening and knowledge, and prevention and control). The confirmatory factor analysis using a 2-parameter item response theory model had a good fit (TLI = .91, RMSEA = .04) to the proposed 3-factor structure. The total scale reliability ranged from .80 for Black participants to .73 for total culturally diverse sample. The three subscales were differentially predictive of family history of cancer. The revised Breast-CLAT scales demonstrated internal consistency reliability and validity in this multiethnic, community-based sample.
Satisfactory Results of the Exeter Revision Femoral Stem Used for Primary Total Hip Arthroplasty.
Desy, Nicholas M; Johnson, Joshua D; Sierra, Rafael J
2017-02-01
The Exeter cemented femoral stem has demonstrated excellent clinical and radiographic outcomes as well as long-term survivorship free from aseptic loosening. A shorter revision stem (125 mm) with a 44 offset became available for the purpose of cement-in-cement revision situations. In certain cases, this shorter revision stem may be used for various primary total hip arthroplasties (THAs) where the standard length stem would require distally reaming the femoral canal. We sought to report on the early to midterm results of this specific stem when used for primary THA regarding (1) clinical and radiographic outcomes, (2) complications, and (3) survivorship. Twenty-nine patients (33 hips) underwent a hybrid THA using the smaller revision Exeter cemented femoral stem. Twenty-five patients (28 hips) had at least 2 years of follow-up and were assessed for clinical and radiographic outcomes. All 33 hips were included in the analysis of complications and survivorship. The Kaplan-Meier survivorship was performed using revision for all causes and for aseptic loosening as the end points. The average clinical follow-up was 4 years (range, 2-7). Harris Hip Scores improved from a mean preoperative value of 56 (range, 23-96) to 90 (range, 51-100) at the latest follow-up. All patients demonstrated superior cement mantles with no signs of loosening. One patient suffered a B2 periprosthetic fracture and 1 patient experienced 2 episodes of instability. The 5-year Kaplan-Meier survivorship was 96.7% for all causes of revision and was 100% using aseptic loosening as the end point. The shorter Exeter revision cemented femoral stem has favorable early to midterm clinical and radiographic outcomes when used for primary THA with a low complication rate and is a viable option in patients with narrow femoral canals where uncemented stem fixation is not desired. Copyright © 2016 Elsevier Inc. All rights reserved.
Private and Commercial Pilot; Heliocoptor. Flight Test Guide, Part 61 Revised, AC 61-59.
ERIC Educational Resources Information Center
Federal Aviation Administration (DOT), Washington, DC. Flight Standards Service.
This flight test guide assists the applicant and his instructor in preparing for the Private or Commercial Pilot Rotocraft Certificate with Helicopter Rating under Part 61 (revised) of Federal Aviation Regulations. It contains information and guidance concerning the pilot operations, procedures, and maneuvers relevant to the flight test required…
77 FR 1129 - Revisions to Test Methods and Testing Regulations
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-09
...This action proposes editorial and technical corrections necessary for source testing of emissions and operations. The revisions include the addition of alternative equipment and methods as well as corrections to technical and typographical errors. We also solicit public comment on potential changes to the current procedures for determining emission stratification.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-02
... NUCLEAR REGULATORY COMMISSION [NRC-2012-0195] Software Unit Testing for Digital Computer Software... revised regulatory guide (RG), revision 1 of RG 1.171, ``Software Unit Testing for Digital Computer Software Used in Safety Systems of Nuclear Power Plants.'' This RG endorses American National Standards...
Psychometric Evaluation of the Life Orientation Test-Revised in Treated Opiate Dependent Individuals
ERIC Educational Resources Information Center
Hirsch, Jameson K.; Britton, Peter C.; Conner, Kenneth R.
2010-01-01
We examined internal consistency and test-retest reliability of a measure of dispositional optimism, the Life Orientation Test-Revised, in 121 opiate-dependent patients seeking methadone treatment. Internal consistency was adequate at baseline (alpha = 0.69) and follow-up (alpha = 0.72). Low socioeconomic status and being on disability were…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-25
...The U.S. Nuclear Regulatory Commission (NRC) is issuing a revision to regulatory guide (RG), 1.79, ``Preoperational Testing of Emergency Core Cooling Systems for Pressurized-Water Reactors.'' This RG is being revised to incorporate guidance for preoperational testing of new pressurized water reactor (PWR) designs.
Test Review: An Interview with Amy Gabel--About the WISC-V
ERIC Educational Resources Information Center
Greathouse, Dan; Shaughnessy, Michael F.
2016-01-01
Whenever a major intelligence or achievement test is revised, there is always renewed interest in the underlying structure of the test as well as a renewed interest in the scoring, administration, and interpretation changes. In this interview, Amy Gabel discusses the most recent revision of the "Wechsler Intelligence Scale for Children-Fifth…
Flight Test Guide (Part 61 Revised); Private Pilot Airplane.
ERIC Educational Resources Information Center
Federal Aviation Administration (DOT), Washington, DC. Flight Standards Service.
This guide provides an outline of the skills required to pass the flight test for a Private Pilot Certificate with Airplane Rating under part 61 (revised) of Federal Aviation Regulations. General procedures for flight tests are described and the following pilot operations outlined: preflight operations, airport and traffic pattern operations,…
ERIC Educational Resources Information Center
Swiggett, Wanda D.; Kotloff, Laurie; Ezzo, Chelsea; Adler, Rachel; Oliveri, Maria Elena
2014-01-01
The computer-based "Graduate Record Examinations"® ("GRE"®) revised General Test includes interactive item types and testing environment tools (e.g., test navigation, on-screen calculator, and help). How well do test takers understand these innovations? If test takers do not understand the new item types, these innovations may…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-13
...The Coast Guard proposes to revise regulations related to the design, certification, inspection, and testing of cranes. These regulations apply to cranes installed on Mobile Offshore Drilling Units (MODUs), Offshore Supply Vessels (OSVs), and floating Outer Continental Shelf (OCS) facilities. This revision would update industry standards incorporated by reference with more recent versions, which are used by industry and incorporated in Bureau of Safety and Environmental Enforcement regulations. Additionally, the Coast Guard proposes to revise regulations regarding certification, inspection, and testing of cranes by allowing use of additional organizations to act in lieu of Coast Guard marine inspectors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
John McCord
2007-05-01
This document, which makes changes to Groundwater Flow Model of Corrective Action Units 101 and 102: Central and Western Pahute Mesa, Nevada Test Site, Nye County, Nevada, S-N/99205--076, Revision 0 (June 2006) was prepared to address review comments of this final document by the Nevada Division of Environmental Protection (NDEP) in a letter dated July 19, 2006. The document includes revised pages that address NDEP review comments and comments from other document users. Change bars are included on these pages to identify where the text was revised. In addition to the revised pages, the following clarifications are made: • Onmore » Plate 1 (inserted in the back of the document), the ET Unit legend has been revised. The revised Plate 1 is included and replaces the original Plate 1. • Some of the Appendix D perturbation sensitivity analysis plots included on the CD for Sections D.3.1 and D.3.2 were not properly aligned. A revised CD is provided with all plots properly aligned.« less
Improving the Validity and Reliability of a Health Promotion Survey for Physical Therapists
Stephens, Jaca L.; Lowman, John D.; Graham, Cecilia L.; Morris, David M.; Kohler, Connie L.; Waugh, Jonathan B.
2013-01-01
Purpose Physical therapists (PTs) have a unique opportunity to intervene in the area of health promotion. However, no instrument has been validated to measure PTs’ views on health promotion in physical therapy practice. The purpose of this study was to evaluate the content validity and test-retest reliability of a health promotion survey designed for PTs. Methods An expert panel of PTs assessed the content validity of “The Role of Health Promotion in Physical Therapy Survey” and provided suggestions for revision. Item content validity was assessed using the content validity ratio (CVR) as well as the modified kappa statistic. Therapists then participated in the test-retest reliability assessment of the revised health promotion survey, which was assessed using a weighted kappa statistic. Results Based on feedback from the expert panelists, significant revisions were made to the original survey. The expert panel reached at least a majority consensus agreement for all items in the revised survey and the survey-CVR improved from 0.44 to 0.66. Only one item on the revised survey had substantial test-retest agreement, with 55% of the items having moderate agreement and 43% poor agreement. Conclusions All items on the revised health promotion survey demonstrated at least fair validity, but few items had reasonable test-retest reliability. Further modifications should be made to strengthen the validity and improve the reliability of this survey. PMID:23754935
Schuld, Christian; Franz, Steffen; Brüggemann, Karin; Heutehaus, Laura; Weidner, Norbert; Kirshblum, Steven C; Rupp, Rüdiger
2016-09-01
Prospective cohort study. Comparison of the classification performance between the worksheet revisions of 2011 and 2013 of the International Standards for Neurological Classification of Spinal Cord Injury (ISNCSCI). Ongoing ISNCSCI instructional courses of the European Multicenter Study on Human Spinal Cord Injury (EMSCI). For quality control all participants were requested to classify five ISNCSCI cases directly before (pre-test) and after (post-test) the workshop. One hundred twenty-five clinicians working in 22 SCI centers attended the instructional course between November 2011 and March 2015. Seventy-two clinicians completed the post-test with the 2011 revision of the worksheet and 53 with the 2013 revision. Not applicable. The clinicians' classification performance assessed by the percentage of correctly determined motor levels (ML) and sensory levels, neurological levels of injury (NLI), ASIA Impairment Scales and zones of partial preservations. While no group differences were found in the pre-tests, the overall performance (rev2011: 92.2% ± 6.7%, rev2013: 94.3% ± 7.7%; P = 0.010), the percentage of correct MLs (83.2% ± 14.5% vs. 88.1% ± 15.3%; P = 0.046) and NLIs (86.1% ± 16.7% vs. 90.9% ± 18.6%; P = 0.043) improved significantly in the post-tests. Detailed ML analysis revealed the largest benefit of the 2013 revision (50.0% vs. 67.0%) in a case with a high cervical injury (NLI C2). The results from the EMSCI ISNCSCI post-tests show a significantly better classification performance using the revised 2013 worksheet presumably due to the body-side based grouping of myotomes and dermatomes and their correct horizontal alignment. Even with these proven advantages of the new layout, the correct determination of MLs in the segments C2-C4 remains difficult.
The Music Attentiveness Screening Assessment, Revised (MASA-R): A Study of Technical Adequacy.
Waldon, Eric G; Lesser, Alexander; Weeden, Lydia; Messick, Emily
2016-01-01
Evidence suggests that attention is an important consideration when designing procedural support interventions for children undergoing distressing medical procedures. As such, the extent to which children can attend to musical stimuli used during music-based procedural support interventions would seem important. The Music Attentiveness Screening Assessment (MASA) was designed to assess a child's ability to attend to musical stimuli, but further revisions were deemed necessary to improve administration, test-retest reliability, and interobserver agreement for the measure's items. This study investigated the technical adequacy of the Music Attentiveness Screening Assessment, Revised (MASA-R), with a non-clinical sample of children aged 4 to 9 years by examining (a) Construct validity using comparator instruments measuring auditory attention; (b) Test-retest reliability following a two-week delay; and (c) Interobserver agreement when administered by two independent examiners. This non-clinical sample included 69 children who were administered both items from MASA-R and two comparator instruments: the Auditory Attention subtest from the NEPSY-II (NII-AA) for children aged 5 to 9 years (n = 47); and the Auditory Attention subtest from the Woodcock-Johnson Tests of Cognitive Abilities, 3rd ed. (WJIII-AA), for children aged 4 years (n = 22). A significant proportion of score variance was shared by both MASA-R items and the comparator measures: R (2) = .16, F(2, 66) = 6.30, p = .003. MASA-R score estimates with regard to test-retest reliability (Item I, intra-class correlation [ICC] = .88; Item II, ICC = .91) and interobserver agreement (Item I, ICC = .99; Item II, ICC = .98) also fell into acceptable ranges. Estimates of MASA-R score construct validity, test-retest reliability, and interobserver agreement appear improved over its predecessor, MASA. While findings are promising, additional investigation of its use with a clinical sample is needed before it can be confidently used in pediatrics. © the American Music Therapy Association 2015. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
2004-08-01
base station Attitude Measurement Ashtech ADU-2 Bartington MAG03ML7ONT 3-axis fluxgate magnetometer , Navigation Picodas PNAV100 Model P141-E Real...BBR Test Grid, horizontal difference (outer coil minus scaled inner coil). 46 22 Analytic signal derived from ground-based magnetometer bottom...one meter over UXO-contaminated terrain. As with the magnetic systems, GPS and laser altimetry provide precise positioning to within a few tens of
Test Area C-80 Complex Final Range Environmental Assessment, Revision 1
2009-08-14
C-80 Complex include gaseous chemical materials from current use of ordnance, smokes, and flares, as well as depleted uranium on TA C-80B from...Smoke grenades (various) 430 Flares (various) 430 OS-4 smoke pot 430 C-80B 466 Fog oil 1,000 gallons Ictus nickel foreign weapon exploitation 20...2007b DU = depleted uranium ; ERP = Environmental Restoration Program; LUC = land use control; POI = point of interest A ffected E nvironm ent C hem
Revision surgery after cervical laminoplasty: report of five cases and literature review.
Shigematsu, Hideki; Koizumi, Munehisa; Matsumori, Hiroaki; Iwata, Eiichiro; Kura, Tomohiko; Okuda, Akinori; Ueda, Yurito; Tanaka, Yasuhito
2015-06-01
Revision surgery after laminoplasty is rarely performed, and there are few reports of this procedure in the English literature. To evaluate the reasons why patients underwent revision surgery after laminoplasty and to discuss methods of preventing the need for revision surgery. A literature review with a comparative analysis between previous reports and present cases was also performed. Case report and literature review. Five patients who underwent revision surgery after laminoplasty. Diagnosis was based on the preoperative computed tomography and magnetic resonance imaging findings. Neurologic findings were evaluated using the Japanese Orthopedic Association score. A total of 237 patients who underwent cervical laminoplasty for cervical spondylotic myelopathy from 1990 to 2010 were reviewed. Patients with ossification of the posterior longitudinal ligament, renal dialysis, infection, tumor, or rheumatoid arthritis were excluded. Five patients who underwent revision surgery for symptoms of recurrent myelopathy or radiculopathy were identified, and the clinical courses and radiological findings of these patients were retrospectively reviewed. The average interval from the initial surgery to revision surgery was 15.0 (range 9-19) years. The patients were four men and one woman with an average age at the time of the initial operation of 49.8 (range 34-65) years. Four patients developed symptoms of recurrent myelopathy after their initial surgery, for the following reasons: adjacent segment canal stenosis, restenosis after inadequate opening of the lamina with degenerative changes, and trauma after inadequate opening of the lamina. One patient developed new radiculopathy symptoms because of foraminal stenosis secondary to osteoarthritis at the Luschka and zygapophyseal joints. All patients experienced resolution of their symptoms after revision surgery. Revision surgery after laminoplasty is rare. Inadequate opening of the lamina is one of the important reasons for needing revision surgery. Degenerative changes after laminoplasty may also result in a need for revision surgery. Surgeons should be aware of the degenerative changes that can cause neurologic deterioration after laminoplasty. Copyright © 2015 Elsevier Inc. All rights reserved.
The Morscher Press-Fit Acetabular Component: An Independent Long-Term Review at 18-22 Years.
Gwynne-Jones, David P; Lash, Heath W R; James, Andrew W; Iosua, Ella E; Matheson, John A
2017-08-01
There are relatively few 20-year results of uncemented acetabular components, and most of these are modular designs. This study reports the 20-year results of a monoblock press-fit acetabular component. A total of 122 total hip arthroplasties (111 patients) using the Morscher cup were reviewed at a mean of 19.7 years. The average age at implantation was 57.3 years (range, 36-74 years), and 81 (66%) were men. Twenty-two patients (25 hips) had died. Seven hips were revised, including 5 acetabular revisions. Six patients (6 hips) declined to participate but were known not to have been revised. The mean Oxford hip score was 41.1 (range, 22-48), and the mean reduced Western Ontario and McMaster Universities Osteoarthritis Index score was 5.7/48 (range, 0-24). Eccentric wear was seen in 13 (15.7%) and major osteolysis in 14 (17%) of 82 surviving hips with radiographs. The all-cause revision rate was 0.32 per 100 observed component years (95% confidence interval [CI], 0.13-0.66). The 20-year Kaplan-Meier survival was 93.4% (CI, 86.6-96.8) for all-cause revisions, 95.5% (CI, 89.4-98.1) for any acetabular revision, and 97.1% (CI, 91.2-99.1) for acetabular aseptic loosening, wear, or osteolysis. The Morscher acetabular component has continued to perform well at 20 years despite using conventional polyethylene with results that match or surpass other cementless acetabulae. Copyright © 2017 Elsevier Inc. All rights reserved.
JT8D revised high-pressure turbine cooling and other outer air seal program
NASA Technical Reports Server (NTRS)
Gaffin, W. O.
1979-01-01
The JT8D high pressure turbine was revised to reduce leakage between the blade tip shrouds and the outer air seal, and engine testing was performed to determine the effect on performance. The addition of a second knife-edge on the blade tip shroud, the extension of the honeycomb seal land to cover the added knife-edge and an existing spoiler on the shroud, and a material substitution in the seal support ring to improve thermal growth characteristics are included. A relocation of the blade cooling air discharge to insure adequate cooling flow is required. Significant specific fuel consumption and exhaust gas temperature improvements were demonstrated with the revised turbine in sea level and simulated altitude engine tests. Inspection of the revised seal hardware after these tests showed no unusual wear or degradation.
Private and Commercial Pilot: Ligher-Than-Air Airship. Flight Test Guide. (Part 61 Revised).
ERIC Educational Resources Information Center
Federal Aviation Administration (DOT), Washington, DC. Flight Standards Service.
The flight test guide assists the applicant and his instructor in preparing for the flight test for the Private or Commercial Pilot Certificate with a Lighter-Than-Air Category and Airship Class Rating under Part 61 (revised) of Federal Aviation Regulations. It contains information and guidance concerning pilot operations, procedures, and…
Private and Commercial Pilot: Glider. Flight Test Guide, Part 61 Revised, AC 61-61.
ERIC Educational Resources Information Center
Federal Aviation Administration (DOT), Washington, DC. Flight Standards Service.
This flight test guide assists the applicant and his instructor in preparing for the Private or Commercial Pilot Certificate with Glider Rating under Part 61 (revised) of Federal Aviation Regulations. It contains information and guidance concerning the pilot operations, procedures, and maneuvers relevant to the flight test required for that…
Analysis of on-line clinical laboratory manuals and practical recommendations.
Beckwith, Bruce; Schwartz, Robert; Pantanowitz, Liron
2004-04-01
On-line clinical laboratory manuals are a valuable resource for medical professionals. To our knowledge, no recommendations currently exist for their content or design. To analyze publicly accessible on-line clinical laboratory manuals and to propose guidelines for their content. We conducted an Internet search for clinical laboratory manuals written in English with individual test listings. Four individual test listings in each manual were evaluated for 16 data elements, including sample requirements, test methodology, units of measure, reference range, and critical values. Web sites were also evaluated for supplementary information and search functions. We identified 48 on-line laboratory manuals, including 24 academic or community hospital laboratories and 24 commercial or reference laboratories. All manuals had search engines and/or test indices. No single manual contained all 16 data elements evaluated. An average of 8.9 (56%) elements were present (range, 4-14). Basic sample requirements (specimen and volume needed) were the elements most commonly present (98% of manuals). The frequency of the remaining data elements varied from 10% to 90%. On-line clinical laboratory manuals originate from both hospital and commercial laboratories. While most manuals were user-friendly and contained adequate specimen-collection information, other important elements, such as reference ranges, were frequently absent. To ensure that clinical laboratory manuals are of maximal utility, we propose the following 13 data elements be included in individual test listings: test name, synonyms, test description, test methodology, sample requirements, volume requirements, collection guidelines, transport guidelines, units of measure, reference range, critical values, test availability, and date of latest revision.
Adaptation of the three-dimensional wisdom scale (3D-WS) for the Korean cultural context.
Kim, Seungyoun; Knight, Bob G
2014-10-23
ABSTRACT Background: Previous research on wisdom has suggested that wisdom is comprised of cognitive, reflective, and affective components and has developed and validated wisdom measures based on samples from Western countries. To apply the measurement to Eastern cultures, the present study revised an existing wisdom scale, the three-dimensional wisdom scale (3D-WS, Ardelt, 2003) for the Korean cultural context. Methods: Participants included 189 Korean heritage adults (age range 19-96) living in Los Angeles. We added a culturally specific factor of wisdom to the 3D-WS: Modesty and Unobtrusiveness (Yang, 2001), which captures an Eastern aspect of wisdom. The structure and psychometrics of the scale were tested. By latent cluster analysis, we determined acculturation subgroups and examined group differences in the means of factors in the revised wisdom scale (3D-WS-K). Results: Three factors, Cognitive Flexibility, Viewpoint Relativism, and Empathic Modesty were found using confirmatory factor analysis. Respondents with high biculturalism were higher on Viewpoint Relativism and lower on Empathic Modesty. Conclusion: This study discovered that a revised wisdom scale had a distinct factor structure and item content in a Korean heritage sample. We also found acculturation influences on the meaning of wisdom.
IERL-RTP PROCEDURES MANUAL: LEVEL 1 ENVIRONMENTAL ASSESSMENT BIOLOGICAL TESTS
The manual gives revised procedures for Level 1 environmental assessment biological tests, and supersedes the first edition, EPA-600/7-77-043 (NTIS No. PB 268484), published in April 1977. The revised biological procedures complement the Level 1 chemical and physical procedures p...
ERIC Educational Resources Information Center
Anderson, Daniel; Alonzo, Julie; Tindal, Gerald
2012-01-01
The purpose of this technical report is to document the piloting and scaling of new easyCBM mathematics test items aligned with the Common Core State Standards (CCSS) and to describe the process used to revise and supplement the 2012 research version easyCBM CCSS math tests in Grades 6-8. For all operational 2012 research version test forms (10…
Adjorlolo, Samuel
2018-06-01
The sociocultural differences between Western and sub-Saharan African countries make it imperative to standardize neuropsychological tests in the latter. However, Western-normed tests are frequently administered in sub-Saharan Africa because of challenges hampering standardization efforts. Yet a salient topical issue in the cross-cultural neuropsychology literature relates to the utility of Western-normed neuropsychological tests in minority groups, non-Caucasians, and by extension Ghanaians. Consequently, this study investigates the diagnostic accuracy, sensitivity, and specificity of executive function (EF) tests (The Stroop Test, Trail Making Test, and Controlled Oral Word Association Test), and a Revised Quick Cognitive Screening Test (RQCST) in a sample of 50 patients diagnosed with moderate traumatic brain injury and 50 healthy controls in Ghana. The EF test scores showed good diagnostic accuracy, with area under the curve (AUC) values of the Trail Making Test scores ranging from .746 to .902. With respect to the Stroop Test scores, the AUC values ranged from .793 to .898, while Controlled Oral Word Association Test had AUC value of .787. The RQCST scores discriminated between the groups, with AUC values ranging from .674 to .912. The AUC values of composite EF score and a neuropsychological score created from EF and RQCST scores were .936 and. 942, respectively. Additionally, the Stroop Test, Trail Making Test, EF composite score, and RQCST scores showed good to excellent sensitivities and specificities. In general, this study has shown that commonly used EF tests in Western countries have diagnostic accuracy, sensitivity, and specificity when administered in Ghanaian samples. The findings and implications of the study are discussed.
Yamamoto, Michiko; Doi, Hirohisa; Yamamoto, Ken; Watanabe, Kazuhiro; Sato, Tsugumichi; Suka, Machi; Nakayama, Takeo; Sugimori, Hiroki
2017-01-01
The safe use of drugs relies on providing accurate drug information to patients. In Japan, patient leaflets called Drug Guide for Patients are officially available; however, their utility has never been verified. This is the first attempt to improve Drug Guide for Patients via user testing in Japan. To test and improve communication of drug information to minimize risk for patients via user testing of the current and revised versions of Drug Guide for Patients, and to demonstrate that this method is effective for improving Drug Guide for Patients in Japan. We prepared current and revised versions of the Drug Guide for Patients and performed user testing via semi-structured interviews with consumers to compare these versions for two guides for Mercazole and Strattera. We evenly divided 54 participants into two groups with similar distributions of sex, age, and literacy level to test the differing versions of the Mercazole guide. Another group of 30 participants were divided evenly to test the versions of the Strattera guide. After completing user testing, the participants evaluated both guides in terms of amount of information, readability, usefulness of information, and layout and appearance. Participants were also asked for their opinions on the leaflets. Response rates were 100% for both Mercazole and Strattera. The revised versions of both Guides were superior or equal to the current versions in terms of accessibility and understandability. The revised version of the Mercazole guide showed better ratings for readability, usefulness of information, and layout ( p <0.01) than did the current version, while that for Strattera showed superior readability and layout ( p <0.01). User testing was effective for evaluating the utility of Drug Guide for Patients. Additionally, the revised version had superior accessibility and understandability.
Audit of 117 otoplasties for prominent ear by one surgeon using a cartilage-cutting procedure.
Brian, Tess; Cheng, Paul T; Loo, Stanley S
2018-02-07
The plethora of surgical procedures for prominent ear correction reflects lack of satisfaction with outcomes achieved. This paper describes a cartilage-cutting otoplasty procedure and reports an audit of its outcomes. Discharge coding was used to retrospectively identify patients who had undergone the otoplasty of interest at Middlemore Hospital, Auckland, during the 5 years from March 2010 to the end of February 2015. Hospital records were accessed. Demographic, procedure and patient satisfaction data were recorded and analysed (PASW/SPSS Statistics 18.0). Chi-square test and t-test were used to assess associations, with significance accepted at two-sided P < 0.05. Sixty-four patients underwent the specified otoplasty (54.7% females: mean age 9.5 years (standard deviation, SD: 4.2; range: 4-20)), of whom 93.8% had bilateral procedures with mean surgical time of 61 min (SD: 14; range: 34-94). This was significantly shorter (P < 0.001) than for bilateral surgeries by all other techniques and surgeons in the review period. None of the 117 procedures of interest subsequently had suture extrusion or revision surgery. Mean time from surgery to satisfaction determination was 993 days (SD: 521; range: 111-1850) for 43 (67.2%) patients. 23.3% believed that there had been aesthetically insignificant partial recurrence of prominence, typically of one ear only. This was insufficient for all but one patient to consider repeat otoplasty. Surgery outcome was rated 'very satisfactory' and 'satisfactory' by 90.7% and 9.3% of patients/parents, respectively. All would recommend the surgery to others. With infrequent complications and recurrence requiring revision, and without long-term reliance on sutures, the otoplasty reported is time-efficient, safe and generates high patient satisfaction. © 2018 Royal Australasian College of Surgeons.
Yu, Bin-Sheng; Yang, Zhan-Kun; Li, Ze-Min; Zeng, Li-Wen; Wang, Li-Bing; Lu, William Weijia
2011-08-01
An in vitro biomechanical cadaver study. To evaluate the pull-out strength after 5000 cyclic loading among 4 revision techniques for the loosened iliac screw using corticocancellous bone, longer screw, traditional cement augmentation, and boring cement augmentation. Iliac screw loosening is still a clinical problem for lumbo-iliac fusion. Although many revision techniques using corticocancellous bone, larger screw, and polymethylmethacrylate (PMMA) augmentation were applied in repairing pedicle screw loosening, their biomechanical effects on the loosened iliac screw remain undetermined. Eight fresh human cadaver pelvises with the bone mineral density values ranging from 0.83 to 0.97 g/cm were adopted in this study. After testing the primary screw of 7.5 mm diameter and 70 mm length, 4 revision techniques were sequentially established and tested on the same pelvis as follows: corticocancellous bone, longer screw with 100 mm length, traditional PMMA augmentation, and boring PMMA augmentation. The difference of the boring technique from traditional PMMA augmentation is that PMMA was injected into the screw tract through 3 boring holes of outer cortical shell without removing the screw. On an MTS machine, after 5000 cyclic compressive loading of -200∼-500 N to the screw head, axial maximum pull-out strengths of the 5 screws were measured and analyzed. The pull-out strengths of the primary screw and 4 revised screws with corticocancellous bone, longer screw and traditional and boring PMMA augmentation were 1167 N, 361 N, 854 N, 1954 N, and 1820 N, respectively. Although longer screw method obtained significantly higher pull-out strength than corticocancellous bone (P<0.05), the revised screws using these 2 techniques exhibited notably lower pull-out strength than the primary screw and 2 PMMA-augmented screws (P<0.05). Either traditional or boring PMMA screw showed obviously higher pull-out strength than the primary screw (P<0.05); however, no significant difference of pull-out strength was detected between the 2 PMMA screws (P>0.05). Wadding corticocancellous bone and increasing screw length failed to provide sufficient anchoring strength for a loosened iliac screw; however, both traditional and boring PMMA-augmented techniques could effectively increase the fixation strength. On the basis of the viewpoint of minimal invasion, the boring PMMA augmentation may serve as a suitable salvage technique for iliac screw loosening.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-30
... and YY: Application of the Revised Capital Framework to the Capital Plan and Stress Test Rules AGENCY... stress test rules to require a bank holding company with total consolidated assets of $50 billion or more... advanced approaches for a given capital plan and stress test cycle and makes minor, technical changes to...
ERIC Educational Resources Information Center
Rhodes, Katherine T.; Branum-Martin, Lee; Morris, Robin D.; Romski, MaryAnn; Sevcik, Rose A.
2015-01-01
Although it is often assumed that mathematics ability alone predicts mathematics test performance, linguistic demands may also predict achievement. This study examined the role of language in mathematics assessment performance for children with intellectual disability (ID) at less severe levels, on the KeyMath-Revised Inventory (KM-R) with a…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Irene Farnham
This Quality Assurance Project Plan (QAPP) provides the overall quality assurance (QA) program requirements and general quality practices to be applied to the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO) Underground Test Area (UGTA) Sub-Project (hereafter the Sub-Project) activities. The requirements in this QAPP are consistent with DOE Order 414.1C, Quality Assurance (DOE, 2005); U.S. Environmental Protection Agency (EPA) Guidance for Quality Assurance Project Plans for Modeling (EPA, 2002); and EPA Guidance on the Development, Evaluation, and Application of Environmental Models (EPA, 2009). The QAPP Revision 0 supersedes DOE--341, Underground Test Area Quality Assurancemore » Project Plan, Nevada Test Site, Nevada, Revision 4.« less
Kim, Su Bin; Kim, Seong Min
2015-09-01
A small percentage of patients fitted with a gastric band still experience "failure." Here, the authors demonstrate the safety and feasibility of band preserving-laparoscopic gastric plication (BP-LGP), which was designed to improve weight loss and decrease gastric band adjustment frequency and thereby improve patient quality of life. All 6 patients involved in this study had a gastric band in place for more than 1 year; the median interval from gastric banding to BP-LGP was 31.7 months (range, 19.7-49.9 months). Five (83.3%) patients were female. Preoperative median body mass index (BMI) at gastric banding was 35.4 kg/m(2) (range, 31.9-43.9 kg/m(2)), median nadir BMI with the gastric band was 25.7 kg/m(2) (range, 20.9-31.0 kg/m(2)), and percentage excess BMI loss (%EBMIL) ranged from 24.3% to 123.6%. Indications for BP-LGP were as follows: chronic gastric prolapse in 2 patients (33.3%), pouch-esophageal dilatation in 3 (50.0%), and insufficient weight loss in 4 (66.6%), which included 2 patients with weight loss failure (%EBMIL of <30%). The 6 patients consecutively underwent surgery from May 2014 to January 2015. No conversion to open surgery was necessary, and no perioperative complication or mortality occurred. Mean operative time was 190 minutes. All patients showed weight loss after revision and showed resolution of troublesome signs and symptoms. Median follow-up after revision was 7.3 months (range, 5.7-10.1 months), median BMI at last follow-up was 27.6 kg/m(2) (range, 22.7-34.0 kg/m(2)), and median %EBMIL was 75.7% (range, 21.0%-103.6%). Median fill volume before revision was 6.1 mL (range, 2.7-11.0 mL), and median fill volume after revision was 0.3 mL (range, 0.0-5.3 mL). Three patients (50%) had an empty band at last follow-up. This novel method of bariatric revision (modified BP-LGP) might have a role as a salvage procedure in patients with impending gastric band failure.
Revising the Belgian Nursing Minimum Dataset: from concept to implementation.
Sermeus, Walter; van den Heede, Koen; Michiels, Dominik; Delesie, Lucas; Thonon, Olivier; Van Boven, Caroline; Codognotto, Jean; Gillet, Pierre
2005-12-01
The process of revising the Belgian Nursing Minimum Dataset (B-NMDS) started in 2000 and entailed four major phases. The first phase (June-October 2002) involved the development of a conceptual framework based on a literature review and secondary data analysis. The Nursing Interventions Classification (NIC) was selected as a framework for the revision of the original B-NMDS. The second phase (November 2002-September 2003) focused on language development for six care programs evaluated by panels of clinical experts (N=75). These panels identified the following items as priorities for the revised B-NMDS: hospital financing, nurse staffing allocation, assessment of the appropriateness of hospitalisation, and quality management. During this period, we developed a draft instrument with 92 variables using the NIC. This led to an alpha version of a revised B-NMDS. The third phase (October 2003-December 2004) focused on data collection and validation of the new tool. The revised B-NMDS (alpha version) was tested in 158 nursing wards in 66 Belgian hospitals from December 2003 until March 2004. This test generated data for some 95,000 in-patient days. The interrater reliability of the revised B-NMDS was assessed. The criterion-related validity of the revised B-NMDS was compared to that of the original B-NMDS. The discriminative power of the revised B-NMDS was also assessed to select the most relevant variables for data collection. This resulted in a beta version of the revised B-NMDS in December 2004. The records of the revised B-NMDS were linked to the Hospital Discharge Dataset and other mandatory datasets to integrate the revised B-NMDS into the overall healthcare management system. The fourth phase (January 2005-December 2005) is presently focusing on information management. Nationwide implementation is foreseen by January 2007.
Long-term Follow-up of Revision Osteochondral Allograft Transplantation of the Ankle.
Gaul, Florian; Tírico, Luís E P; McCauley, Julie C; Bugbee, William D
2018-05-01
Osteochondral allograft (OCA) transplantation is a useful alternative for treatment of posttraumatic ankle arthritis in young patients but has a relatively high failure rate and further procedures are often required. The purpose of this study was to evaluate outcomes of patients who underwent revision OCA transplantation of the ankle after failed primary OCA transplantation. Twenty patients underwent revision OCA transplantation of the ankle between 1988 and 2015. Mean age was 44 years, 55% (11 of 20) were female. The mean time from primary to revision OCA was 3.0 ± 1.7 years. All patients had a minimum follow-up of 2 years. Outcomes included the American Academy of Orthopaedic Surgeons Foot and Ankle Module (AAOS-FAM) and questionnaires evaluating pain and satisfaction. Failure of the revision OCA was defined as a conversion to arthroplasty, arthrodesis, or amputation. Ten of 20 ankles required further surgery, of which 30% (6 of 20) were considered OCA revision failures (4 arthrodeses, 1 arthroplasty, and 1 amputation). The mean time to failure was 6.7 (range, 0.6-13.1) years. Survivorship of the revision OCA was 84% at 5 years and 65% at 10 years. The 14 patients with grafts remaining in situ had an average follow-up of 10.3 years; mean AAOS-FAM Core Score was 70.5 (range, 42.3-99). Of the patients who answered the follow-up questions, 4 of 7 reported moderate to severe pain, and 5 of 12 were satisfied with the results of the procedure. Although the results of revision ankle OCA transplantation are not inferior to primary OCA transplantation, the high rates of persistent pain, further surgery, and graft failure suggest that the indications for OCA as a revision procedure should be carefully evaluated, with proper patient selection. Considering the treatment alternatives, revising a failed OCA transplantation can be a useful treatment option, especially for young and active patients who wish to avoid arthrodesis or arthroplasty. Level IV, case series.
ERIC Educational Resources Information Center
Harrington, Robert G.; And Others
1992-01-01
Examined concurrent validity between Woodcock-Johnson Psycho-Educational Battery-Revised Tests of Cognitive Ability (WJ-R, COG) (Early Development) and Wechsler Preschool and Primary Scale of Intelligence-Revised (WPPSI-R) by administering instruments to 30 normal 3, 4, and 5 year olds. WJ-R Broad Cognitive Ability and WPPSI-R Full Scale IQ and…
NASA Astrophysics Data System (ADS)
Haq, Gary; Martini, Giorgio; Mellios, Giorgos
2014-10-01
Evaporative emissions of non-methane volatile organic compounds (NMVOCs) arise from the vehicle's fuel system due to changes in ambient and vehicle temperatures, and contribute to urban smog. This paper presents an economic analysis of the societal costs and benefits of implementing a revised European evaporative emission test procedure for petrol vehicles under four scenarios for the period 2015-2040. The paper concludes that the most cost-effective option is the implementation of an aggressive purging strategy over 48 h and improved canister durability (scenario 2+). The average net benefit of implementing this scenario is €146,709,441 at a 6% discount rate. Per vehicle benefits range from €6-9 but when fuel savings benefits are added, total benefits range from €13-18. This is compared to average additional cost per vehicle of €9.
Lee, Ho Min; Kim, Jong Pil; Chung, Phil Hyun; Kang, Suk; Kim, Young Sung; Go, Bo Seong
2018-05-24
Knee dislocation following total knee replacement arthroplasty is a rare but serious complication. The incidence of dislocation following primary total knee arthroplasty with posterior stabilized implants ranges from 0.15 to 0.5%, and posterior dislocation after revision total knee arthroplasty is even rarer. Here, we report the case of a 76-year-old male who presented with posterior dislocation after posterior stabilized revision total knee arthroplasty.
Altieri, Maria S; Yang, Jie; Telem, Dana A; Meng, Ziqi; Frenkel, Catherine; Halbert, Caitlin; Talamini, Mark; Pryor, Aurora D
2016-05-01
We sought to determine the rate of revision and explant of the laparoscopic adjustable gastric banding (LAGB) over a ten-year period in the state of New York. Following IRB approval, the SPARCS administrative database was used to identify LAGB placement from 2004 to 2010. We tracked patients who underwent band placement with subsequent removal/revision, followed by conversion to either Roux-en-Y gastric bypass (RYBG) or sleeve gastrectomy (SG) between 2004 and 2013. McNemar test and Chi-square test were used to compare complications between primary procedure and subsequent revision and to compare complication rates and mortality rates, respectively. Log-rank test was used to assess patient characteristics and comorbidities. p < 0.05 was considered significant. During a 7-year period, there were 19,221 records of LAGB placements and 6567 records of revisions or removal. We were able to follow up 3158 (16.43 %) who subsequently underwent a band removal or revision over the course of this period. An additional 3606 patients had no records in the state of New York following the procedure, thus making the rate of revision 20.22 %. Initial revision procedures were coded as band removal in 32.77 % (n = 1035), band revision in 30.53 % (n = 964), band removal and replacement in 19.09 % (n = 603), removal and conversion to SG in 5.64 % (n = 178), or removal and conversion to RYGB in 11.97 % (n = 378). From the 3158 patients, 2515 (79.64 %) required only one revision. Six hundred and forty-three patients underwent two or more revisions. Thirty-one out of 3158 (0.0098 %) patients had complications at their initial operation, but 919 (29.1 %) had complications during revision (p < 0.0001). Over a 7-year period, at least 20.22 % of LAGB required removal or revision. Based on all case numbers, total revision rate may be as high as 34.2 %. Although the band is believed to be a reversible procedure, revisional procedures are significantly more morbid than the initial procedure.
30 CFR 33.38 - Electrical parts.
Code of Federal Regulations, 2011 CFR
2011-07-01
... MINING PRODUCTS DUST COLLECTORS FOR USE IN CONNECTION WITH ROCK DRILLING IN COAL MINES Test Requirements... Part 18 of Subchapter D of this chapter (Bureau of Mines Schedule 2, revised, the current revision of..., the current revision of which is Schedule 2F). (c) Units with electrical parts and designed for...
30 CFR 33.38 - Electrical parts.
Code of Federal Regulations, 2010 CFR
2010-07-01
... MINING PRODUCTS DUST COLLECTORS FOR USE IN CONNECTION WITH ROCK DRILLING IN COAL MINES Test Requirements... Part 18 of Subchapter D of this chapter (Bureau of Mines Schedule 2, revised, the current revision of..., the current revision of which is Schedule 2F). (c) Units with electrical parts and designed for...
What Is High School Economics? TEL Revision and Pretest Findings.
ERIC Educational Resources Information Center
Walstad, William B.; Soper, John C.
1988-01-01
Argues there is limited research data about student knowledge of economic concepts at the secondary school education level. Describes the development, validation, and national norming of the revised Test of Economic Literacy (TEL) and presents findings from the 1986 pretest analysis of the revised TEL. (BSR)
Lee, Byoung-Joo; Kyung, Hee-Soo; Yoon, Seong-Dae
2015-09-01
The purpose of this study was to determine the degree of infection control and postoperative function for new articulating metal-on-cement spacer. A retrospective study of 19 patients (20 cases), who underwent a two-stage revision arthroplasty using mobile cement prosthesis, were followed for a minimum of 2 years. This series consisted of 16 women and 3 men, having an overall mean age of 71 years. During the first stage of revision, the femoral implant and all the adherent cement was removed, after which it was autoclaved before replacement. The tibial component was removed and a doughy state, antibiotic-impregnated cement was inserted on the tibial side. To achieve joint congruency, intraoperative molding was performed by flexing and extending the knee joint. Each patient was evaluated clinically and radiologically. The clinical assessments included range of motion, and the patients were scored as per the Hospital for Special Surgery (HSS) and Knee Society (KS) criteria. The mean range of knee joint motion was 70° prior to the first stage operation and 72° prior to the second stage revision arthroplasty; following revision arthroplasty, it was 113° at the final follow-up. The mean HSS score and KS knee and function scores were 86, 82, and 54, respectively, at the final follow-up. The success rate in terms of infection eradication was 95% (19/20 knees). No patient experienced soft tissue contracture requiring a quadriceps snip. This novel technique provides excellent radiological and clinical outcomes. It offers a high surface area of antibiotic-impregnated cement, a good range of motion between first and second stage revision surgery for the treatment of chronic infection after total knee arthroplasty, and is of a reasonable cost.
Advanced Grid Support Functionality Testing for Florida Power and Light
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nelson, Austin; Martin, Gregory; Hurtt, James
This report describes the results of laboratory testing of advanced photovoltaic (PV) inverter testing undertaken by the National Renewable Energy Laboratory (NREL) on behalf of the Florida Power and Light Company (FPL). FPL recently commissioned a 1.1 MW-AC PV installation on a solar carport at the Daytona International Speedway in Daytona Beach, Florida. In addition to providing a source of clean energy production, the site serves as a live test bed with 36 different PV inverters from eight different manufacturers. Each inverter type has varied support for advanced grid support functions (GSFs) that are becoming increasingly commonplace, and are beingmore » required through revised interconnection standards such as UL1741, IEEE1547, and California (CA) Rule 21. FPL is interested in evaluating the trade-offs between different GSFs, their compliance to emerging standards, and their effects on efficiency and reliability. NREL has provided a controlled laboratory environment to undertake such a study. This work covered nine different classes of tests to compare inverter capabilities and performance for four different inverters that were selected by FPL. The test inverters were all three-phase models rated between 24-36 kW, and containing multiple PV input power point trackers. Advanced grid support functions were tested for functional behavior, and included fixed power factor operation, voltage-ride through, frequency ride-through, volt-var control, and frequency-Watt control. Response to abnormal grid conditions with GSFs enabled was studied through anti-islanding, fault, and load rejection overvoltage tests. Finally, efficiency was evaluated across a range of operating conditions that included power factor, output power, and input voltage variations. Test procedures were derived from requirements of a draft revision of UL741, CA Rule 21, and/or previous studies at NREL. This reports summarizes the results of each test case, providing a comparative performance analysis between the four test inverters. Inverters were mostly able to meet the requirements of their stated GSF capabilities, with deviations from expected results discussed throughout the report. There were mixed results across the range of abnormal tests, and results were often dependent on the capability of each test inverter to deploy the GSFs of interest. Detailed test data has been provided to FPL to support future decision making with respect to inverter selection and GSF deployment in the field.« less
78 FR 41285 - Airworthiness Directives; Pilatus Aircraft Ltd. Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-10
... manual). The limitations were revised to include an emergency fuel control system adjustment test. We are... a 300 Flight Hour (FH) hour inspection on the Emergency Fuel Control System (FCS). For the reason...., maintenance manual). The limitations were revised to include an emergency fuel control system adjustment test...
Norman, Marc A; Moore, David J; Taylor, Michael; Franklin, Donald; Cysique, Lucette; Ake, Chris; Lazarretto, Deborah; Vaida, Florin; Heaton, Robert K
2011-08-01
Memory and executive functioning are two important components of clinical neuropsychological (NP) practice and research. Multiple demographic factors are known to affect performance differentially on most NP tests, but adequate normative corrections, inclusive of race/ethnicity, are not available for many widely used instruments. This study compared demographic contributions for widely used tests of verbal and visual learning and memory (Brief Visual Memory Test-Revised, Hopkins Verbal Memory Test-Revised) and executive functioning (Stroop Color and Word Test, Wisconsin Card Sorting Test-64) in groups of healthy Caucasians (n = 143) and African Americans (n = 103). Demographic factors of age, education, gender, and race/ethnicity were found to be significant factors on some indices of all four tests. The magnitude of demographic contributions (especially age) was greater for African Americans than for Caucasians on most measures. New, demographically corrected T-score formulas were calculated for each race/ethnicity. The rates of NP impairment using previously published normative standards significantly overestimated NP impairment in African Americans. Utilizing the new demographic corrections developed and presented herein, NP impairment rates were comparable between the two race/ethnicities and were unrelated to the other demographic characteristics (age, education, gender) in either race/ethnicity group. Findings support the need to consider extended demographic contributions to neuropsychological test performance in clinical and research settings.
Sawyer, R John; Testa, S Marc; Dux, Moira
2017-01-01
Various research studies and neuropsychology practice organizations have reiterated the importance of developing embedded performance validity tests (PVTs) to detect potentially invalid neurocognitive test data. This study investigated whether measures within the Hopkins Verbal Learning Test - Revised (HVLT-R) and the Brief Visuospatial Memory Test - Revised (BVMT-R) could accurately classify individuals who fail two or more PVTs during routine clinical assessment. The present sample of 109 United States military veterans (Mean age = 52.4, SD = 13.3), all consisted of clinically referred patients and received a battery of neuropsychological tests. Based on performance validity findings, veterans were assigned to valid (n = 86) or invalid (n = 23) groups. Of the 109 patients in the overall sample, 77 were administered the HLVT-R and 75 were administered the BVMT-R, which were examined for classification accuracy. The HVLT-R Recognition Discrimination Index and the BVMT-R Retention Percentage showed good to adequate discrimination with an area under the curve of .78 and .70, respectively. The HVLT-R Recognition Discrimination Index showed sensitivity of .53 with specificity of .93. The BVMT-R Retention Percentage demonstrated sensitivity of .31 with specificity of .92. When used in conjunction with other PVTs, these new embedded PVTs may be effective in the detection of invalid test data, although they are not intended for use in patients with dementia.
NASA Astrophysics Data System (ADS)
Alturki, Uthman T.
The goal of this research was to research, design, and develop a hypertext program for students who study biology. The Ecology Hypertext Program was developed using Research and Development (R&D) methodology. The purpose of this study was to place the final "product", a CD-ROM for learning biology concepts, in the hands of teachers and students to help them in learning and teaching process. The product was created through a cycle of literature review, needs assessment, development, and a cycle of field tests and revisions. I applied the ten steps of R&D process suggested by Borg and Gall (1989) which, consisted of: (1) Literature review, (2) Needs assessment, (3) Planning, (4) Develop preliminary product, (5) Preliminary field-testing, (6) Preliminary revision, (7) Main field-testing, (8) Main revision, (9) Final field-testing, and (10) Final product revision. The literature review and needs assessment provided a support and foundation for designing the preliminary product---the Ecology Hypertext Program. Participants in the needs assessment joined a focus group discussion. They were a group of graduate students in education who suggested the importance for designing this product. For the preliminary field test, the participants were a group of high school students studying biology. They were the potential user of the product. They reviewed the preliminary product and then filled out a questionnaire. Their feedback and suggestions were used to develop and improve the product in a step called preliminary revision. The second round of field tasting was the main field test in which the participants joined a focus group discussion. They were the same group who participated in needs assessment task. They reviewed the revised product and then provided ideas and suggestions to improve the product. Their feedback were categorized and implemented to develop the product as in the main revision task. Finally, a group of science teachers participated in this study by reviewing the product and then filling out the questionnaire. Their suggestions were used to conduct the final step in R&D methodology, the final product revision. The primary result of this study was the Ecology Hypertext Program. It considered a small attempt to give students an opportunity to learn through an interactive hypertext program. In addition, using the R&D methodology was an ideal procedure for designing and developing new educational products and material.
ERIC Educational Resources Information Center
Klieger, David M.; Belur, Vinetha; Kotloff, Lauren J.
2017-01-01
This survey study investigated how graduate school admissions committees perceive and use the "GRE"® General Test and "GRE"® Subject Tests after the launch of the "GRE"® revised General Test in August 2011. These perceptions and uses impact the validity of the tests. Prior research about the perceptions and uses of…
Hancock, Douglas S; Sharplin, Paul K; Larsen, Peter D; Phillips, Fredrick Ts
2018-05-01
To assess early radiological and functional outcomes of revision hip surgery with a cementless press-fit design femoral stem. A retrospective review of 48 consecutive revision total hip replacements using the RECLAIM revision hip system, between October 2012 and August 2015. Radiographic assessment was undertaken with serial anteroposterior (AP) X-rays of the pelvis. Risk factors for subsidence were evaluated. Prospective clinical follow up was performed on 21 patients to assess functional outcomes. Mean stem subsidence was 1.1 mm (95% confidence interval[CI]: 0.63-1.57). Median follow up of 12 months. An inverse relationship was observed between level of subsidence and femoral stem diameter r = -0.45, p = 0.001. Subsidence at the time of follow-up assessment was correlated with initial subsidence (correlation coefficient rho 0.69, p = 0.001). The mean Merle d'Aubigne score at the latest follow up was 14.2 (range 8-17). The mean OHS was 34.1 (range 15-48). Early radiological and functional outcomes for the RECLAIM revision system showed very low levels of subsidence and good functional outcomes. There was an association with smaller diameter femoral stems and greater levels of subsidence.
NASA Technical Reports Server (NTRS)
Creagh, John W. R.
1950-01-01
The compressor from the XT-46 turbine-propeller engine was revised by removing the last two rows of stator blades and by eliminating the interstage leakage paths described in a previous report. With the revised compressor, the flow choking point shifted upstream into the last rotor-blade row but the maximum weight flow was not increased over that of the original compressor. The flow range of the revised compressor was reduced to about two-thirds that obtained with the original compressor. The later stages of the compressor did not produce the design static-pressure increase probably because of excessive boundary-layer build-up in this region. Measurements obtained in the ninth-stage stator showed that the performance up to this station was promising but that the last three stages of the compressor were limiting the useful operating range of the preceding stages. Some modifications in flow-passage geometry and blade settings are believed to be necessary, however, before any major improvements in over-all compressor performance can be obtained.
Raichle, Christina J; Eckstein, Jens; Lapaire, Olav; Leonardi, Licia; Brasier, Noé; Vischer, Annina S; Burkard, Thilo
2018-06-01
Hypertensive disorders are one of the leading causes of maternal death worldwide. Several smartphone apps claim to measure blood pressure (BP) using photoplethysmographic signals recorded by smartphone cameras. However, no single app has been validated for this use to date. We aimed to validate a new, promising smartphone algorithm. In this subgroup analysis of the iPARR trial (iPhone App Compared With Standard RR Measurement), we tested the Preventicus BP smartphone algorithm on 32 pregnant women. The trial was conducted based on the European Society of Hypertension International Protocol revision 2010 for validation of BP measuring devices in adults. Each individual received 7 sequential BP measurements starting with the reference device (Omron-HBP-1300) and followed by the smartphone measurement, resulting in 96 BP comparisons. Validation requirements of the European Society of Hypertension International Protocol revision 2010 were not fulfilled. Mean (±SD) systolic BP disagreement between the test and reference devices was 5.0 (±14.5) mm Hg. The number of absolute differences between test and reference device within 5, 10, and 15 mm Hg was 31, 53, and 64 of 96, respectively. A Bland-Altman plot showed an overestimation of smartphone-determined systolic BP in comparison with reference systolic BP in low range but an underestimation in medium-range BP. The Preventicus BP smartphone algorithm failed the accuracy criteria for estimating BP in pregnant women and was thus not commercialized. Pregnant women should be discouraged from using BP smartphone apps, unless there are algorithms specifically validated according to common protocols. URL: https://www.clinicaltrials.gov. Unique identifier: NCT02552030. © 2018 American Heart Association, Inc.
Comparison of revision surgeries for one- to two-level cervical TDR and ACDF from 2002 to 2011.
Nandyala, Sreeharsha V; Marquez-Lara, Alejandro; Fineberg, Steven J; Singh, Kern
2014-12-01
Cervical total disc replacement (TDR) and anterior cervical discectomy and fusion (ACDF) provide comparable outcomes for degenerative cervical pathology. However, revisions of these procedures are not well characterized. The purpose of this study is to examine the rates, epidemiology, perioperative complications, and costs between the revision procedures and to compare these outcomes with those of primary cases. This study is a retrospective database analysis. A total of 3,792 revision and 183,430 primary cases from the Nationwide Inpatient Sample (NIS) database from 2002 to 2011 were included. Incidence of revision cases, patient demographics, length of stay (LOS), in-hospital costs, mortality, and perioperative complications. Patients who underwent revision for either one- to two-level cervical TDR or ACDF were identified. SPSS v.20 was used for statistical analysis with χ(2) test for categorical data and independent sample t test for continuous data. The relative risk for perioperative complications with revisions was calculated in comparison with primary cases using a 95% confidence interval. An alpha level of less than 0.05 denoted statistical significance. There were 3,536 revision one- to two-level ACDFs and 256 revision cervical TDRs recorded in the NIS database from 2002 to 2011. The revision cervical TDR cohort demonstrated a significantly greater LOS (3.18 vs. 2.25, p<.001), cost ($16,998 vs. $15,222, p=.03), and incidence of perioperative wound infections (13.6 vs. 5.3 per 1,000, p<.001) compared with the ACDF revision cohort (p<.001). There were no differences in mortality between the revision surgical cohorts. Compared with primary cases, both revision cohorts demonstrated a significantly greater LOS and cost. Furthermore, patients who underwent revision demonstrated a greater incidence and risk for perioperative wound infections, hematomas, dysphagia, and neurologic complications relative to the primary procedures. This study demonstrated a significantly greater incidence of perioperative wound infection, LOS, and costs associated with a TDR revision compared with a revision ACDF. We propose that these differences are by virtue of the inherently more invasive nature of revising TDRs. In addition, compared with primary cases, revision procedures are associated with greater costs, LOS, and complications including wound infections, dysphagia, hematomas, and neurologic events. These additional risks must be considered before opting for a revision procedure. Copyright © 2014 Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
McNeil, Malcolm R.; Pratt, Sheila R.; Szuminsky, Neil; Sung, Jee Eun; Fossett, Tepanta R. D.; Fassbinder, Wiltrud; Lim, Kyoung Yuel
2015-01-01
Purpose: This study assessed the reliability and validity of intermodality associations and differences in persons with aphasia (PWA) and healthy controls (HC) on a computerized listening and 3 reading versions of the Revised Token Test (RTT; McNeil & Prescott, 1978). Method: Thirty PWA and 30 HC completed the test versions, including a…
2013-01-01
Background To successfully implement the recommendations of critical care nutrition guidelines, one potential approach is to identify barriers to providing optimal enteral nutrition (EN) in the intensive care unit (ICU), and then address these barriers systematically. Therefore, the purpose of this study was to develop a questionnaire to assess barriers to enterally feeding critically ill patients and to conduct preliminary validity testing of the new instrument. Methods The content of the questionnaire was guided by a published conceptual framework, literature review, and consultation with experts. The questionnaire was pre-tested on a convenience sample of 32 critical care practitioners, and then field tested with 186 critical care providers working at 5 hospitals in North America. The revised questionnaire was pilot tested at another ICU (n = 43). Finally, the questionnaire was distributed to a random sample of ICU nurses twice, two weeks apart, to determine test retest reliability (n = 17). Descriptive statistics, exploratory factor analysis, Cronbach alpha, intraclass correlations (ICC), and kappa coefficients were conducted to assess validity and reliability. Results We developed a questionnaire with 26 potential barriers to delivery of EN asking respondents to rate their importance as barriers in their ICU. Face and content validity of the questionnaire was established through literature review and expert input. The factor analysis indicated a five-factor solution and accounted for 72% of the variance in barriers: guideline recommendations and implementation strategies, delivery of EN to the patient, critical care provider attitudes and behavior, dietitian support, and ICU resources. Overall, the indices of internal reliability for the derived factor subscales and the overall instrument were acceptable (subscale Cronbach alphas range 0.84 – 0.89). However, the test retest reliability was variable and below acceptable thresholds for the majority of items (ICC’s range −0.13 to 0.70). The within group agreement, an indices reflecting the reliability of aggregating individual responses to the ICU level was also variable (ICC’s range 0.0 to 0.82). Conclusions We developed a questionnaire to identify barriers to enteral feeding in critically ill patients. Additional studies are planned to further revise and evaluate the reliability and validity of the instrument. PMID:24305039
Riouallon, Guillaume; Bouyer, Benjamin; Wolff, Stéphane
2016-08-01
Little is known about the long-term status of patients operated for spine deformities. The aim of this study was to determine the survival of primary fusion in adult idiopathic scoliosis and identify the risk factors of revision surgery. Adult patients who underwent primary fusion for idiopathic scoliosis between 1983 and 2011 were included in a continuous monocentric retrospective series. Any additional surgery was registered for survival analysis. Survival and follow-up were estimated by the Kaplan-Meier method and an analysis was performed to identify the risk factors of revision surgery. This series included 447 women (86.5 %) and 70 men (13.5 %) reviewed after a mean follow-up of 7 years (range 0-26.4). Mean age was 44.4 years. Fusion was performed on a median 11 levels (range 3-15); revision rate was 13 % (CI 10-17), 18 % (CI 14-23) and 20 % (CI 16-26) at 5, 10 and 15 years, respectively. Revision surgery was associated with age, anterior release, length of fusion, the inferior limit of fusion, post-operative sagittal balance and junctional kyphosis. The length of fusion (HR 1.13 per vertebrae fused, p = 0.007) and the lower limit of fusion (HR 5.9, p < 0.001) remained independent predictors of revision surgery on multivariate analysis. This series evaluated the risk of revision surgery following spinal fusion for idiopathic scoliosis. Our results show that the risk seemed to increase linearly with a rate of nearly 20 % after 10 years. The length and lower limit of fusion are the main risk factors for revision surgery. Level IV (e.g. case series).
Jenny, J-Y; Adamczewski, B; De Thomasson, E; Godet, J; Bonfait, H; Delaunay, C
2016-04-01
The diagnosis of periprosthetic joint infection can be challenging, in part because there is no universal diagnostic test. Current recommendations include several diagnostic criteria, and are mainly based on the results of deep microbiological samples; however, these only provide a diagnosis after surgery. A predictive infection score would improve the management of revision arthroplasty cases. The purpose of this study was to define a composite infection score using standard clinical, radiological and laboratory data that can be used to predict whether an infection is present before a total hip arthroplasty (THA) revision procedure. The infection score will make it possible to differentiate correctly between infected and non-infected patients in 75% of cases. One hundred and four records from patients who underwent THA revision for any reason were analysed retrospectively: 43 with infection and 61 without infection. There were 54 men and 50 women with an average age of 70±12 years (range 30-90). A univariate analysis was performed to look for individual discriminating factors between the data in the medical records of infected and non-infected patients. A multivariate analysis subsequently integrated these factors together. A composite score was defined and its diagnostic effectiveness was evaluated as the percentage of correctly classified records, along with its sensitivity and specificity. The score consisted of the following individually weighed factors: body mass index, presence of diabetes, mechanical complication, wound healing disturbance and fever. This composite infection score was able to distinguish correctly between the infected patients (positive score) and non-infected patients (negative score) in 78% of cases; the sensitivity was 57% and the specificity 93%. Once this score is evaluated prospectively, it could be an important tool for defining the medical - surgical strategy during THA revision, no matter the reason for revision. Level IV - retrospective study. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Telemetry Group Inter-Range Instrumentation Group Range Commanders Council
1975-11-01
PMR-AFWR-NWC-AFETR-• AMTEC -ADTC-AFFTC-AFSCF REPLY TO STEWS-SA-R ATTN OF, SuWu, IRIG Standard 106-73 (Revised November 1975) TO% Holders of IRIG...51 8-11 General Characteristics . . . 51 8-12 Physical Characteristics 52 8-13 Magnetic/ Electrical Characteristics 54 v REVISED NOVEMBER...13g. Head Polarity Magnetic Tape, 7-3c. Humidity Stability, 8-12d. E Electrical Resistance, 8-12h. I Environmental Conditions, 8-11b. Erasure, 8-13j
RCBI-II: The Second Revision of the Revised Cyber Bullying Inventory
ERIC Educational Resources Information Center
Topcu, Çigdem; Erdur-Baker, Özgür
2018-01-01
The aim of this study is to update the Turkish version of the Revised Cyber Bullying Inventory (RCBI) and eliminate specific technology names. Validity and reliability tests were carried out with 1,803 high school students. The updated version of the RCBI yields valid and reliable scores measuring cyberbullying and victimization.
Changing the Subject: The Place of Revisions in Grammatical Development
ERIC Educational Resources Information Center
Rispoli, Matthew
2018-01-01
Purpose: This article focuses on toddlers' revisions of the sentence subject and tests the hypothesis that subject diversity (i.e., the number of different subjects produced) increases the probability of subject revision. Method: One-hour language samples were collected from 61 children (32 girls) at 27 months. Spontaneously produced, active…
The mechanical effect of the existing cement mantle on the in-cement femoral revision.
Keeling, Parnell; Lennon, Alexander B; Kenny, Patrick J; O'Reilly, Peter; Prendergast, Patrick J
2012-08-01
Cement-in-cement revision hip arthroplasty is an increasingly popular technique to replace a loose femoral stem which retains much of the original cement mantle. However, some concern exists regarding the retention of the existing fatigued and aged cement in such cement-in-cement revisions. This study investigates whether leaving an existing fatigued and aged cement mantle degrades the mechanical performance of a cement-in-cement revision construct. Primary cement mantles were formed by cementing a polished stem into sections of tubular steel. If in the test group, the mantle underwent conditioning in saline to simulate ageing and was subject to a fatigue of 1 million cycles. If in the control group no such conditioning or fatigue was carried out. The cement-in-cement procedure was then undertaken. Both groups underwent a fatigue of 1 million cycles subsequent to the revision procedure. Application of a Mann-Whitney test on the recorded subsidence (means: 0.51, 0.46, n=10+10, P=0.496) and inducible displacement (means: 0.38, 0.36, P=0.96) revealed that there was no statistical difference between the groups. This study represents further biomechanical investigation of the mechanical behaviour of cement-in-cement revision constructs. Results suggest that pre-revision fatigue and ageing of the cement may not be deleterious to the mechanical performance of the revision construct. Thus, this study provides biomechanical evidence to back-up recent successes with this useful revision technique. Copyright © 2012 Elsevier Ltd. All rights reserved.
Preliminary Investigation of the 1991 Medical College Admission Test Factor Structure.
ERIC Educational Resources Information Center
Li, Weichang; Mitchell, Karen J.
A substantially revised Medical College Admission Test (MCAT) was introduced in spring 1991. The new examination is designed to assess critical thinking skills, basic concepts and problem solving facility in science, and writing skills. This paper reports preliminary findings on the factor structure of the revised MCAT, which consists of four…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-22
... DEPARTMENT OF AGRICULTURE Agricultural Marketing Service [AMS-CN-13-0044] Cotton Classing, Testing..., for an extension and revision to the currently approved information collection entitled Cotton... proposal to: Shethir M. Riva, Chief, Research and Promotion Staff, Cotton and Tobacco Programs, AMS, USDA...
New Ways of Classroom Assessment. Revised
ERIC Educational Resources Information Center
Brown, J. D., Ed.
2013-01-01
In this revised edition in the popular New Ways Series, teachers have once again been given an opportunity to show how they do assessment in their classrooms on an everyday basis. Often feeling helpless when confronted with large-scale standardized testing practices, teachers here offer classroom testing created with the direct aim of helping…
75 FR 35038 - Agency Information Collection Activities; Proposed Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-21
... components of the RED, as well as the needs of culturally and linguistically diverse patients; (2) To pre-test the revised RED Toolkit in ten varied hospital settings, evaluating how the RED Toolkit is... intensity of technical assistance (TA). (3) To modify the revised RED Toolkit based on pre-testing and to...
Test Review: Wechsler Abbreviated Scale of Intelligence, Second Edition
ERIC Educational Resources Information Center
Irby, Sarah M.; Floyd, Randy G.
2013-01-01
The Wechsler Abbreviated Scale of Intelligence, Second Edition (WASI-II; Wechsler, 2011) is a brief intelligence test designed for individuals aged 6 through 90 years. It is a revision of the Wechsler Abbreviated Scale of Intelligence (WASI; Wechsler, 1999). During revision, there were three goals: enhancing the link between the Wechsler…
76 FR 71977 - Update of the NICEATM-ICCVAM Five-Year Plan: Request for Comments
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-21
... testing and (2) research, development, translation, and validation of new and revised non-animal and other...-animal and other alternative assays for integration into Federal agency testing programs (ICCVAM, 2008... of areas of high priority for new and revised non-animal and alternative assays to reduce, refine...
Weir, Nichola-Jane M; Pattison, Sally H; Kearney, Paddy; Stafford, Bob; Gormley, Gerard J; Crockard, Martin A; Gilpin, Deirdre F; Tunney, Michael M; Hughes, Carmel M
2018-01-01
Urinary Tract Infections (UTIs) are common bacterial infections, second only to respiratory tract infections and particularly prevalent within primary care. Conventional detection of UTIs is culture, however, return of results can take between 24 and 72 hours. The introduction of a point of care (POC) test would allow for more timely identification of UTIs, facilitating improved, targeted treatment. This study aimed to obtain consensus on the criteria required for a POC UTI test, to meet patient need within primary care. Criteria for consideration were compiled by the research team. These criteria were validated through a two-round Delphi process, utilising an expert panel of healthcare professionals from across Europe and United States of America. Using web-based questionnaires, panellists recorded their level of agreement with each criterion based on a 5-point Likert Scale, with space for comments. Using median response, interquartile range and comments provided, criteria were accepted/rejected/revised depending on pre-agreed cut-off scores. The first round questionnaire presented thirty-three criteria to the panel, of which 22 were accepted. Consensus was not achieved for the remaining 11 criteria. Following response review, one criterion was removed, while after revision, the remaining 10 criteria entered the second round. Of these, four were subsequently accepted, resulting in 26 criteria considered appropriate for a POC test to detect urinary infections. This study generated an approved set of criteria for a POC test to detect urinary infections. Criteria acceptance and comments provided by the healthcare professionals also supports the development of a multiplex point of care UTI test.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burmeister, Mark
2016-11-01
The Corrective Action Unit (CAU) 411 Closure Report (CR) was published in June 2016 (NNSA/NFO, 2016). The purpose of this addendum is to clarify language in the CR relating to the field instrument for the detection of low-energy radiation (FIDLER), provide the waste disposal documentation for waste generated during the corrective action investigation (CAI), and reference a letter from the U.S. Air Force (USAF) regarding the closure of CAU 411.
Test Area B-75 Final Range Environmental Assessment (REA), Revision 1
2010-08-01
Committee on Hearing, Bioacoustics, and Biomechanics CO Carbon Monoxide CS/CSS Combat Support/Combat Service Support CWA Clean Water Act CZMA Coastal...Explosives 88 0 0 0 MK-82, AFX-644-3 HE FILL 12 0 0 0 Lasers LASER GUIDED TRAINING RD 0 4 0 16 LASER OPS, 1 HR 0 14 0 56 Mines MINE AT HEAVY M15 0 462 0...Primary) 40,000 µg/m³ = Micrograms per Cubic Meter; Avg = Average; CO = Carbon Monoxide ; hr = Hour; NOx = Nitrogen Oxides; PM = Particulate
Objectivity, Reliability, and Validity of the Bent-Knee Push-Up for College-Age Women
ERIC Educational Resources Information Center
Wood, Heather M.; Baumgartner, Ted A.
2004-01-01
The revised push-up test has been found to have good validity but it produces many zero scores for women. Maybe there should be an alternative to the revised push-up test for college-age women. The purpose of this study was to determine the objectivity, reliability, and validity for the bent-knee push-up test (executed on hands and knees) for…
ERIC Educational Resources Information Center
Attali, Yigal
2014-01-01
Previous research on calculator use in standardized assessments of quantitative ability focused on the effect of calculator availability on item difficulty and on whether test developers can predict these effects. With the introduction of an on-screen calculator on the Quantitative Reasoning measure of the "GRE"® revised General Test, it…
An Examination of the Perceived Importance of Technical Competence in Acquisition Project Management
1991-09-01
Develop (First Draft) Instructions Critique (Revision) Answerability Pilot Test (Second Draft) Analysis Response Mode Revision Useability Preparation...appropriate questionnaire items. Initially, the set of questions developed for the study reflected a few shortcomings. A pilot test of the first draft among...resulted. First, feedback from the pilot test indicated a need to reduce the completion time. Because the multiple choice format required several
Erkens, Roy H.J.; Oosterhof, Jessica; Westra, Lubbert Y.T.; Maas, Paul J.M.
2017-01-01
Abstract We present revisions of the Neotropical genera Ruizodendron and Pseudephedranthus (Annonaceae). Ruizodendron includes a single species R. ovale. Pseudephedranthus now comprises two species, with the description of the new species P. enigmaticus sp. nov. extending the range of the genus beyond the Upper Rio Negro region of Brazil (Amazonas) and adjacent Venezuela (P. fragrans), to include Guyana, Suriname, and the Brazilian state of Pará. An overview is provided of current revisions of Neotropical Annonaceae genera that will aid in accessing proper species information for this frequently encountered tropical rain forest family. PMID:29158697
Code of Federal Regulations, 2013 CFR
2013-10-01
... diagnostic laboratory test for which a new or substantially revised Healthcare Common Procedure Coding System Code is assigned on or after January 1, 2005. Substantially Revised Healthcare Common Procedure Coding...
Code of Federal Regulations, 2012 CFR
2012-10-01
... diagnostic laboratory test for which a new or substantially revised Healthcare Common Procedure Coding System Code is assigned on or after January 1, 2005. Substantially Revised Healthcare Common Procedure Coding...
Code of Federal Regulations, 2014 CFR
2014-10-01
... diagnostic laboratory test for which a new or substantially revised Healthcare Common Procedure Coding System Code is assigned on or after January 1, 2005. Substantially Revised Healthcare Common Procedure Coding...
Alépée, N; Grandidier, M H; Cotovio, J
2014-03-01
The EpiSkin™ skin corrosion test method was formally validated and adopted within the context of OECD TG 431 for identifying corrosive and non-corrosive chemicals. The EU Classification, Labelling and Packaging Regulation (EU CLP) system requires the sub-categorisation of corrosive chemicals into the three UN GHS optional subcategories 1A, 1B and 1C. The present study was undertaken to investigate the usefulness of the validated EpiSkin™ test method to identify skin corrosive UN GHS Categories 1A, 1B and 1C using the original and validated prediction model and adapted controls for direct MTT reduction. In total, 85 chemicals selected by the OECD expert group on skin corrosion were tested in three independent runs. The results obtained were highly reproducible both within (>80%) and between (>78%) laboratories when compared with historical data. Moreover the results obtained showed that the EpiSkin™ test method is highly sensitive (99%) and specific (80%) in discriminating corrosive from non-corrosive chemicals and allows reliable and relevant identification of the different skin corrosive UN GHS subcategories, with high accuracies being obtained for both UN GHS Categories 1A (83%) and 1B/1C (76%) chemicals. The overall accuracy of the test method to subcategorise corrosive chemicals into three or two UN GHS subcategories ranged from 75% to 79%. Considering those results, the revised OECD Test Guideline 431 permit the use of EpiSkin™ for subcategorising corrosive chemicals into at least two classes (Category 1A and Category 1B/1C). Copyright © 2013. Published by Elsevier Ltd.
School Safety Handbook. Revised.
ERIC Educational Resources Information Center
Association of School Business Officials International, Reston, VA.
The revised edition of this handbook represents a concerted effort to bring school safety to the forefront of business managers' daily and long-range planning activities. Although statistics show few fatalities on school grounds, schools appear to have a high frequency and incident rate of nonfatal injuries. According to the introduction, school…
Aging: Prospects and Issues. Revised. 1976.
ERIC Educational Resources Information Center
Davis, Richard H., Ed.
Completely revised and updated since its first edition in 1973, the book explores an even wider range of concerns regarding gerontology. Part 1 presents an overview of the multiple aspects of gerontology, and includes the following chapters: (1) Aging: Prospects and Issues, Richard H. Davis; (2) Aging: The Psychologist's Perspective, James E.…
76 FR 10874 - Implementation of Revised Lacey Act Provisions
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-28
... DEPARTMENT OF AGRICULTURE Animal and Plant Health Inspection Service [Docket No. APHIS-2008-0119] Implementation of Revised Lacey Act Provisions AGENCY: Animal and Plant Health Inspection Service, USDA. ACTION... Lacey Act to expand its protections to a broader range of plant species, extended its reach to encompass...
Kowalczewski, Jacek B.; Chevalier, Yan; Okon, Tomasz; Innocenti, Bernardo; Bellemans, Johan
2015-01-01
Introduction Correct restoration of the joint line is generally considered as crucial when performing total knee arthroplasty (TKA). During revision knee arthroplasty however, elevation of the joint line occurs frequently. The general belief is that this negatively affects the clinical outcome, but the reasons are still not well understood. Material and methods In this cadaveric in vitro study the biomechanical consequences of joint line elevation were investigated using a previously validated cadaver model simulating active deep knee squats and passive flexion-extension cycles. Knee specimens were sequentially tested after total knee arthroplasty with joint line restoration and after 4 mm joint line elevation. Results The tibia rotated internally with increasing knee flexion during both passive and squatting motion (range: 17° and 7° respectively). Joint line elevation of 4 mm did not make a statistically significant difference. During passive motion, the tibia tended to become slightly more adducted with increasing knee flexion (range: 2°), while it went into slighlty less adduction during squatting (range: –2°). Neither of both trends was influenced by joint line elevation. Also anteroposterior translation of the femoral condyle centres was not affected by joint line elevation, although there was a tendency for a small posterior shift (of about 3 mm) during squatting after joint line elevation. In terms of kinetics, ligaments lengths and length changes, tibiofemoral contact pressures and quadriceps forces all showed the same patterns before and joint line elevation. No statistically significant changes could be detected. Conclusions Our study suggests that joint line elevation by 4 mm in revision total knee arthroplasty does not cause significant kinematic and kinetic differences during passive flexion/extension movement and squatting in the tibio-femoral joint, nor does it affect the elongation patterns of collateral ligaments. Therefore, clinical problems after joint line elevation are probably situated in the patello-femoral joint or caused by joint line elevation of more than 4 mm. PMID:25995746
Code of Federal Regulations, 2010 CFR
2010-10-01
... laboratory test for which a new or substantially revised Healthcare Common Procedure Coding System Code is assigned on or after January 1, 2005. Substantially Revised Healthcare Common Procedure Coding System Code...
Code of Federal Regulations, 2011 CFR
2011-10-01
... laboratory test for which a new or substantially revised Healthcare Common Procedure Coding System Code is assigned on or after January 1, 2005. Substantially Revised Healthcare Common Procedure Coding System Code...
Development of a qualification standard for adhesives used in hybrid microcircuits
NASA Technical Reports Server (NTRS)
Licari, J. J.; Weigand, B. L.; Soykin, C. A.
1981-01-01
Improved qualification standards and test procedures for adhesives used in microelectronic packaging are developed. The test methods in specification for the Selection and Use of Organic Adhesives in Hybrid Microcircuits are reevaluated versus industry and government requirements. Four electrically insulative and four electrically conductive adhesives used in the assembly of hybrid microcircuits are selected to evaluate the proposed revised test methods. An estimate of the cost to perform qualification testing of an adhesive to the requirements of the revised specification is also prepared.
The effects of lip revision surgery on nasolabial esthetics in patients with cleft lip.
Mercado, A M; Phillips, C; Vig, K W L; Trotman, C-A
2014-11-01
1) To determine the concordance among surgeons on subjective assessments of nasolabial esthetics in children with repaired cleft lip; and 2) to evaluate longitudinal changes in nasolabial esthetics in relation to cleft lip revision surgery. School of Dentistry at University of North Carolina, Chapel Hill. Children with repaired unilateral cleft lip: 32 had lip revision surgery and 27 did not have surgery. Retrospective observational study from a non-randomized clinical trial. Ratings of nasolabial esthetics performed by six surgeons using the Asher-McDade scale at baseline and 12-month follow-up. Concordance among surgeons ranged from poor to acceptable. Nasolabial ratings at follow-up were better in the Revision group than in the Non-Revision group, although differences were small. The most prevalent change in the Revision Group was improvement in one or more units on the scale, while 'no change' was most prevalent in the Non-Revision group. Participants in the Revision group were more likely to receive a 'no' in relation to the need for lip or nose revision at the follow-up visit. There were mild esthetic improvements observed in relation to lip revision surgery, which should be interpreted with caution given the subjectivity of the rating method used. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Vermont long range transportation plan
DOT National Transportation Integrated Search
2002-01-01
Vermont Agency of Transportation (VTrans) conducted this update of the Long-Range Transportation Plan to review and revise the recommendations of the Long-Range Transportation Plan of 1995. The three objectives from the previous plan were further ref...
ERIC Educational Resources Information Center
Hadeed, Julie
2014-01-01
The aim of this study was to test reliabilities and validations for the Arabic translation of the Early Childhood Environment Rating Scale, Revised (ECERS-R) scale [Harms, T., Clifford, R. M., & Cryer, D. (1998). "Early childhood environment rating scale, revised edition." New York: Teachers College Press]. ECERS-R mean scores were…
49 CFR Appendix C to Part 227 - Audiometric Baseline Revision
Code of Federal Regulations, 2011 CFR
2011-10-01
... FRA STS. The two ears are examined separately and independently for improvement and for worsening. If one ear meets the criteria for revision of baseline, then the baseline is revised for that ear only. Therefore, if the two ears show different hearing trends, the baseline for the left ear may be from one test...
49 CFR Appendix C to Part 227 - Audiometric Baseline Revision
Code of Federal Regulations, 2012 CFR
2012-10-01
... FRA STS. The two ears are examined separately and independently for improvement and for worsening. If one ear meets the criteria for revision of baseline, then the baseline is revised for that ear only. Therefore, if the two ears show different hearing trends, the baseline for the left ear may be from one test...
Gothardo, Ana C L O; Savioli, Amanda F; Santos, Dayanna S; Lamas, José L T
2013-08-01
The aim of the study was to evaluate the accuracy of the oscillometric blood pressure section in the DX 2020 Dixtal multiparametric monitor in adults according to the European Society of Hypertension-International Protocol as revised in 2010 (ESH-IP 2010). The blood pressure was sequentially verified in 33 individuals admitted to an adult ICU (18 men, mean age 44 years) with a mercury column sphygmomanometer (two observers) and the DX 2020 test device (one supervisor). Ninety-nine pairs of differences were obtained. Data analysis followed the ESH-IP 2010 requirements. In the first requirement, the DX 2020 device failed in the validation study in the 5, 10, and 15 mmHg ranges. From the 99 pairs of differences, only 43/73, 69/87, and 81/96 were obtained for systolic blood pressure and 29/65, 56/81, and 71/93 were obtained for diastolic blood pressure. In the second requirement, at least 24 individuals should have, from their comparisons, two under 0-5 mmHg ranges, which was observed only with 16 individuals in the systolic and nine in the diastolic range. Moreover, at maximum, only three readings could have differences of more than 5 mmHg, and this was observed in 10 individuals in the systolic range and 17 individuals in the diastolic range. The DX 2020 automatic multiparametric monitor for blood pressure measurement has not been recommended for clinical use according to the ESH-IP 2010. It is important to highlight that this work refers only to a blood pressure measurement module and that the same conclusion cannot be drawn for its other functions.
The revised Generalized Expectancy for Success Scale: a validity and reliability study.
Hale, W D; Fiedler, L R; Cochran, C D
1992-07-01
The Generalized Expectancy for Success Scale (GESS; Fibel & Hale, 1978) was revised and assessed for reliability and validity. The revised version was administered to 199 college students along with other conceptually related measures, including the Rosenberg Self-Esteem Scale, the Life Orientation Test, and Rotter's Internal-External Locus of Control Scale. One subsample of students also completed the Eysenck Personality Inventory, while another subsample performed a criterion-related task that involved risk taking. Item analysis yielded 25 items with correlations of .45 or higher with the total score. Results indicated high internal consistency and test-retest reliability.
Sanchez-Sotelo, Joaquin; Wagner, Eric R; Sim, Franklin H; Houdek, Matthew T
2017-12-20
Reverse total shoulder arthroplasty (RTSA) performed in the setting of massive proximal humeral bone loss often requires special reconstructive techniques. Restoration of the proximal part of the humerus with an allograft provides a number of theoretical benefits, including implant support, restoration of humeral length, deltoid tensioning, and an opportunity to repair the posterior aspect of the cuff to improve strength in external rotation and repair of the subscapularis to improve stability. However, reverse allograft-prosthesis composites (APCs) are costly, are technically demanding to use, and can be compromised by progressive allograft resorption. Between 2005 and 2012, the lead author used an APC reconstruction in 8 primary and 18 revision RTSAs (26 patients; mean age, 62 years; mean body mass index, 27.9 kg/m). The indications for the primary RTSAs included severe proximal humeral bone loss after trauma (n = 5) and tumor resection (n = 3). The indications in the revision setting were failed hemiarthroplasty (n = 11), anatomic total shoulder arthroplasty (n = 4), and reverse arthroplasty (n = 3). The most common reason for revision was instability (n = 10). A compression plate was used for graft-to-host fixation in all shoulders. Shoulders were assessed for pain, motion, American Shoulder and Elbow Surgeons (ASES) score, Simple Shoulder Test (SST) score, Neer score, revision or reoperation, radiographic evidence of graft union or resorption, and implant fixation. The mean duration of follow-up was 4 years (range, 2 to 10 years). RTSA using an APC construct resulted in substantial improvements in pain scores (p < 0.0001), elevation (p < 0.0001), and external rotation (p = 0.004). With the numbers available, there were no significant differences in clinical outcomes between primary and revision cases. No patients required revision surgery for nonunion at the host-allograft junction. The mean time to union was 7 months, with 1 patient requiring bone-grafting for delayed union. Other complications included dislocation, deep infection, graft fracture, and periprosthetic fracture distal to the previous APC construct in 1 patient each. The 2 and 5-year revision-free survival rate was 96%. Reconstruction of proximal humeral bone loss with an APC at the time of primary or revision RTSA is safe and effective, with acceptable functional outcomes and complication rates. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Mulero-Portela, Ana L.; Colón-Santaella, Carmen L.; Cruz-Gomez, Cynthia
2010-01-01
The purpose of this study was to perform a cross-cultural adaptation of the Disability of Arm, Shoulder, and Hand (DASH) questionnaire to Spanish for Puerto Rico. Five steps were followed for the cross-cultural adaptation: forward translations into Spanish for Puerto Rico, synthesis of the translations, back translations into English, revision by an expert committee, and field test of the prefinal version. Psychometric characteristics of reliability and construct validity were evaluated for the final version. Internal consistency of the final version was high (Cronbach's α = 0.97) and item-to-total correlations were moderate (range from 0.44 to 0.85). Construct validity was evaluated by correlating the DASH with the scales of the Functional Assessment of Cancer Therapy - Breast. Fair to moderate correlations found in this study between the DASH and most scales of the Functional Assessment of Cancer Therapy - Breast support the construct validity of the Puerto Rico-Spanish DASH. The final version of the questionnaire was revised and approved by the Institute for Work and Health of Canada. Revisions to the original DASH English version are recommended. This version of the DASH is valid and reliable, and it can be used to evaluate outcomes in both clinical and research settings. PMID:19901616
NASA Astrophysics Data System (ADS)
Jiango, Homin; Liuo, Howard; Guzzino, Kim
2016-07-01
In this study, the design of a 4 bit, 10-gigasamples-per-second analog-to-digital converter (ADC) printed circuit board assembly (PCBA) was revised, manufactured, and tested. It is used for digitizing radio telescopes. An Adsantec ANST7120-KMA flash ADC chip was used, as in the original design. Associated with the field-programmable gate array platform developed by the Collaboration for Astronomy Signal Processing and Electronics Research community, the developed PCBA provides data acquisition systems with a wider bandwidth and simplifies the intermediate frequency section. The current version of the PCBA exhibits an analog bandwidth of up to 10 GHz (3 dB loss), and the chip exhibits an analog bandwidth of up to 18 GHz. This facilitates second and third Nyquist sampling. The following worstcase performance parameters were obtained from the revised PCBA at over 5 GHz: spurious-free dynamic range of 12 dB, signal-to-noise and distortion ratio of 2 dB, and effective number of bits of 0.7. The design bugs in the ADC chip caused the poor performance. The vendor created a new batch run and confirmed that the ADC chips of the new batch will meet the specifications addressed in its data sheet.
Skinner, Stanley A; Holdefer, Robert N
2014-04-01
Intervention-mediated recovery from adversely changed evoked potential recordings may provide evidence for improved outcomes during neurophysiological intraoperative monitoring. However, these reversible signal changes (RSCs) are ambiguous because the patient's neurologic status cannot be known either at signal decline or after intervention. This article describes methods to reduce this ambiguity. Randomized control trials are not always possible or ethical. Recent thought on grading evidence has acknowledged that guidelines first described by Sir Austin Bradford Hill may support evidence for causation. Causality guidelines identified RSCs most likely to be truly positive in three reported studies. Diagnostic statistics were revised accordingly. A range of revised positive predictive values and likelihood ratios was calculated in the three studies, using causality guidelines. The revised data were similar to those reported for other diagnostic tests used in medicine. The RSCs may be assessed using causality guidelines for more accurate reporting of diagnostic statistics while preserving information related to surgical intervention and recovery that is lost with end of surgery diagnostics or when RSCs are ignored. A method is described for including RSCs in diagnostic statistics. This approach will more readily permit assessment of the value of neurophysiological intraoperative monitoring in prediction and prevention of neurologic deficits.
ERIC Educational Resources Information Center
Sherman, Tracy; Shulman, Brian B.
1999-01-01
This study examined test characteristics of the Pediatric Language Acquisition Screening Tool for Early Referral-Revised (PLASTER-R), a set of developmental questionnaires for children 3 to 60 months of age. The PLASTER-R was moderately to highly successful in identifying children within normal limits for language development. Test-retest…
The Bulimia Test--Revised: Validation with "DSM-IV" Criteria for Bulimia Nervosa.
ERIC Educational Resources Information Center
Thelen, Mark H.; And Others
1996-01-01
The Bulimia Test--Revised (BULIT-R) was given to 23 female subjects who met the criteria for bulimia in the "Diagnostic and Statistical Manual of Mental Disorders" (DSM-IV) and 124 female controls. The BULIT-R appears to be a valid instruction for identifying individuals who meet DSM-IV criteria for bulimia. (SLD)
ERIC Educational Resources Information Center
Finlayson, Shannon B.; Obrzut, John E.
1993-01-01
Administered Quick Neurological Screening Test-Revised (QNST-R) to 122 elementary-aged children diagnosed with learning disabilities. QNST-R appeared to measure primarily lower order sensory perception/processing and fine and gross motoric skills, which are thought presumably to serve as basis for later higher order cognitive functions. Age, but…
NASA Technical Reports Server (NTRS)
Lauenstein, Jean-Marie
2016-01-01
The JEDEC JESD57 test standard, Procedures for the Measurement of Single-Event Effects in Semiconductor Devices from Heavy-Ion Irradiation, is undergoing its first revision since 1996. This presentation will provide an overview of some of the key proposed updates to the document.
Consumer Education: A Conceptual Structure and Planning Guide for Senior High Schools in Wisconsin.
ERIC Educational Resources Information Center
Appleton Public Schools, WI.
Prepared by junior and senior high teachers, the curriculum guide is an interdisciplinary approach by the business education, home economics, and social studies departments to a consumer education course. The initial development of materials was field tested and revised; a second-year field testing of the revised curriculum and a final analysis…
A Confirmatory Factor Analysis of the Life Orientation Test-Revised with Competitive Athletes
ERIC Educational Resources Information Center
Appaneal, Renee N.
2012-01-01
Current reviews outside of sport indicate that the Life Orientation Test-Revised (LOT-R) items load on two separate factors (optimism and pessimism) and, therefore, should be treated as independent constructs. However, researchers in the sport sciences continue to use the single composite score reflecting a unidimensional definition of optimism.…
Summaries of Research on the Revised Illinois Test of Psycholinguistics. Final Report.
ERIC Educational Resources Information Center
Kirk, Samuel A.; Elkins, John
Summarized are 68 research studies from 1970 to 1975 on the Revised Illinois Test of Psycholinguistic Abilities (ITPA), particularly as it relates to learning disabilities. The reviews have been organized by the following areas (the number of studies in each section and sample study topics are in parentheses): studies comparing the experimental…
ERIC Educational Resources Information Center
Cheng, Sanyin; Zhang, Li-Fang
2014-01-01
The present study pioneered in adopting test accommodations to validate the Thinking Styles Inventory-Revised II (TSI-R2; Sternberg, Wagner, & Zhang, 2007) among Chinese university students with hearing impairment. A series of three studies were conducted that drew their samples from the same two universities, in which accommodating test…
ERIC Educational Resources Information Center
Oktedalen, Tuva; Hagtvet, Knut A.
2011-01-01
Confirmatory factor analysis and Multiple Indicators, Multiple Causes (MIMIC) modeling were employed to investigate psychometric properties of a revised adaptation of the Norwegian version of the Test Anxiety Inventory (RTAIN) in a sample of 456 students. The study supported the Norwegian version as a useful inventory for measuring the components…
ERIC Educational Resources Information Center
Qasem, Mousa; Foote, Rebecca
2010-01-01
This study tested the predictions of the revised hierarchical (RHM) and morphological decomposition (MDM) models with Arabic-English bilinguals. The RHM (Kroll & Stewart, 1994) predicts that the amount of activation of first language translation equivalents is negatively correlated with second language (L2) proficiency. The MDM (Frost, Forster, &…
NASA Astrophysics Data System (ADS)
Young, B. A.; Gao, Xiaosheng; Srivatsan, T. S.
2009-10-01
In this paper we compare and contrast the crack growth rate of a nickel-base superalloy (Alloy 690) in the Pressurized Water Reactor (PWR) environment. Over the last few years, a preponderance of test data has been gathered on both Alloy 690 thick plate and Alloy 690 tubing. The original model, essentially based on a small data set for thick plate, compensated for temperature, load ratio and stress-intensity range but did not compensate for the fatigue threshold of the material. As additional test data on both plate and tube product became available the model was gradually revised to account for threshold properties. Both the original and revised models generated acceptable results for data that were above 1 × 10 -11 m/s. However, the test data at the lower growth rates were over-predicted by the non-threshold model. Since the original model did not take the fatigue threshold into account, this model predicted no operating stress below which the material would effectively undergo fatigue crack growth. Because of an over-prediction of the growth rate below 1 × 10 -11 m/s, due to a combination of low stress, small crack size and long rise-time, the model in general leads to an under-prediction of the total available life of the components.
NASA Astrophysics Data System (ADS)
Reddy, A. Nallapa; Nagendra, R.
2017-12-01
The foraminifer taxon Bolliella adamsi Banner et Blow, 1959 is found to co-occur with index planktic foraminifer taxa of the Late Pliocene (Zone N21) in a core of 2.60 m at 1300 m water depth off Tuticorin, Bay of Bengal. This taxon has been previously known as a Holocene taxon of the Indo-Pacific province. This study significantly revises the known stratigraphic range of B. adamsi from the Late Pliocene (uppermost part of Zone N21) to the Holocene in the Bay of Bengal area.
The Revised DCDQ: Is It a Suitable Screening Measure for Motor Difficulties in Adolescents?
ERIC Educational Resources Information Center
Pannekoek, Linda; Rigoli, Daniela; Piek, Jan P.; Barrett, Nicholas C.; Schoemaker, Marina
2012-01-01
The parent-rated Developmental Coordination Disorder Questionnaire (DCDQ) has been revised to incorporate a wider age range, including adolescence. In this exploratory study, internal consistency and validity of the DCDQ-2007 was assessed using a community-based sample of 87 adolescents. Psychometric properties of the DCDQ-2007 were investigated…
ERIC Educational Resources Information Center
Wilson, Sue
2012-01-01
Pre-service primary (elementary) teachers' mathematics anxiety affects their engagement with and future teaching of mathematics. The study measured the range of mathematics anxiety in 219 pre-service teachers starting a teacher education course in an Australian university. They responded to the Revised Mathematics Anxiety Scale (RMARS) and a set…
Accuracy of Revised and Traditional Parallel Analyses for Assessing Dimensionality with Binary Data
ERIC Educational Resources Information Center
Green, Samuel B.; Redell, Nickalus; Thompson, Marilyn S.; Levy, Roy
2016-01-01
Parallel analysis (PA) is a useful empirical tool for assessing the number of factors in exploratory factor analysis. On conceptual and empirical grounds, we argue for a revision to PA that makes it more consistent with hypothesis testing. Using Monte Carlo methods, we evaluated the relative accuracy of the revised PA (R-PA) and traditional PA…
Alexander, Angel M.; Flynn, Kathryn E.; Hahn, Elizabeth A.; Jeffery, Diana D.; Keefe, Francis J.; Reeve, Bryce B.; Schultz, Wesley; Reese, Jennifer Barsky; Shelby, Rebecca A.; Weinfurt, Kevin P.
2014-01-01
Introduction There is a significant gap in research regarding the readability and comprehension of existing sexual function measures. Patient-reported outcome measures may use terms not well understood by respondents with low literacy. Aim To test comprehension of words and phrases typically used in sexual function measures to improve validity for all individuals, including those with low literacy. Methods We recruited 20 men and 28 women for cognitive interviews on version 2.0 of the PROMIS Sexual Function and Satisfaction measures. We assessed participants’ reading level using the word reading subtest of the Wide Range Achievement Test (WRAT). Sixteen participants were classified as having low literacy. Main Outcome Measures In the first round of cognitive interviews, each survey item was reviewed by 5 or more people, at least 2 of whom had lower than a ninth-grade reading level (low literacy). Patient feedback was incorporated into a revised version of the items. In the second round of interviews, an additional 3 or more people (at least 1 with low literacy) reviewed each revised item. Results Participants with low literacy had difficulty comprehending terms such as aroused, orgasm, erection, ejaculation, incontinence, and vaginal penetration. Women across a range of literacy levels had difficulty with clinical terms like labia and clitoris. We modified unclear terms to include parenthetical descriptors or slang equivalents, which generally improved comprehension. Conclusions Common words and phrases used across measures of self-reported sexual function are not universally understood. Researchers should appreciate these misunderstandings as a potential source of error in studies using self-reported measures of sexual function. PMID:24902984
Synovial Calprotectin: An Inexpensive Biomarker to Exclude a Chronic Prosthetic Joint Infection.
Wouthuyzen-Bakker, Marjan; Ploegmakers, Joris J W; Ottink, Karsten; Kampinga, Greetje A; Wagenmakers-Huizenga, Lucie; Jutte, Paul C; Kobold, Anneke C M
2018-04-01
To diagnose or exclude a chronic prosthetic joint infection (PJI) can be a clinical challenge. Therefore, sensitive and specific biomarkers are needed in the diagnostic work-up. Calprotectin is a protein with antimicrobial properties and is released by activated neutrophils, making it a specific marker for infection. Because of its low costs and ability to obtain a quantitative value as a point of care test, it is an attractive marker to use in clinical practice. In addition, the test is already used in routine care in most hospitals for other indications and therefore easy to implement. Between June 2015 and June 2017 we collected synovial fluid of all consecutive patients who underwent revision surgery of a prosthetic joint because of chronic pain with or without prosthetic loosening. Synovial calprotectin was measured using a lateral flow immunoassay. A PJI was defined by the diagnostic criteria described by the Musculoskeletal Infection Society. Fifty-two patients with chronic pain were included. A PJI was diagnosed in 15 of 52 (29%) patients. The median calprotectin in the PJI group was 859 mg/L (interquartile range 86-1707) vs 7 mg/L (interquartile range 3-25) in the control group (P < .001). With a cut-off value of 50 mg/L, synovial calprotectin showed a sensitivity, specificity, positive predictive value, and negative predictive value of 86.7%, 91.7%, 81.3%, and 94.4%, respectively. Synovial calprotectin is a useful and cheap biomarker to use in the diagnostic work-up of patients with chronic pain, especially to exclude a PJI prior to revision surgery. Copyright © 2017 Elsevier Inc. All rights reserved.
Mohammed, Riazuddin; Hayward, Keith; Mulay, Sanjay; Bindi, Frank; Wallace, Murray
2015-03-01
The concept of a dual-mobility hip socket involves the standard femoral head component encased in a larger polyethylene liner, which in turn articulates inside a metal shell implanted in the native acetabulum. The aim of this study was to assess outcomes from using a Serf Novae(®) Dual Mobility Acetabular cup (Orthodynamics Ltd, Gloucestershire, UK) to address the problem of instability in primary and revision total hip arthroplasty (THA). A retrospective review was carried out of all hip arthroplasties performed in a District General Hospital utilising the dual-mobility socket from January 2007 to December 2012. Clinical and radiological outcomes were analysed for 44 hips in 41 patients, comprising 20 primary and 24 revision THA. The average age of the study group was 70.8 years (range 56-84 years) for primary and 76.4 years (range 56-89 years) for revision arthroplasty. Among the primary THA, always performed for hip osteoarthritis or in presence of osteoarthritic changes, the reasons to choose a dual mobility cup were central nervous system problems such as Parkinson's disease, stroke, dementia (10), hip fracture (5), failed hip fracture fixation (2), severe fixed hip deformity (2) and diffuse peripheral neuropathy (1). The indications for revisions were recurrent dislocation (17), aseptic loosening with abductor deficiency (4), failed hemiarthroplasty with abductor deficiency (2) and neglected dislocation (1). At a mean follow-up of 22 months (range 6-63 months), none of the hips had any dislocation, instability or infection and no further surgical intervention was required. Radiological assessment showed that one uncemented socket in a revision arthroplasty performed for recurrent dislocation had changed position, but was stable in the new position. The patient did not have complications from this and did not need any surgical intervention. Even though postoperative hip stability depends on several factors other than design-related ones, our study shows promising early results for reducing the risk of instability in this challenging group of patients undergoing primary and revision hip arthroplasty. IV.
Adverse Reactions to Metal on Metal Are Not Exclusive to Large Heads in Total Hip Arthroplasty.
Lombardi, Adolph V; Berend, Keith R; Adams, Joanne B; Satterwhite, Keri L
2016-02-01
There is some suggestion that smaller diameter heads in metal-on-metal total hip arthroplasty (MoM THA) may be less prone to the adverse reactions to metal debris (ARMD) seen with large-diameter heads. We reviewed our population of patients with small head (≤ 32 mm) MoM THA to determine (1) the frequency of ARMD; (2) potential risk factors for ARMD in this population; and (3) the etiology of revision and Kaplan-Meier survivorship with revision for all causes. Small-diameter head MoM devices were used in 9% (347 of 3753) of primary THAs during the study period (January 1996 to March 2005). We generally used these implants in younger, more active, higher-demand patients. Three hundred hips (258 patients) had MoM THA using a titanium modular acetabular component with a cobalt-chromium tapered insert and were available for review with minimum 2-year followup (mean, 10 years; range, 2-19 years). Complete followup was available in 86% of hips (300 of 347). Clinical records and radiographs were reviewed to determine the frequency and etiology of revision. Kaplan-Meier survivorship analysis was performed. ARMD frequency was 5% (14 of 300 hips) and represented 70% (14 of 20) of revisions performed. Using multivariate analysis, no variable tested, including height, weight, body mass index, age, cup diameter, cup angle, use of screws, stem diameter, stem type, head diameter, preoperative clinical score, diagnosis, activity level, or sex, was significant as a risk factor for revision. Twenty hips have been revised: two for infection, four for aseptic loosening, and 14 for ARMD. Kaplan-Meier analysis revealed survival free of component revision for all causes was 95% at 10 years (95% confidence interval [CI], 91%-97%), 92% at 15 years (95% CI, 87%-95%), and 72% at 19 years (95% CI, 43%-90%), and survival free of component revision for aseptic causes was 96% at 10 years (95% CI, 92%-98%), 92% at 15 years (95% CI, 88%-95%), and 73% at 19 years (95% CI, 43%-90%). The late onset and devastating nature of metal-related failures is concerning with this small-diameter MoM device. Although the liner is modular, it cannot be exchanged and full acetabular revision is required. Patients with all MoM THA devices should be encouraged to return for clinical and radiographic followup, and clinicians should maintain a low threshold to perform a systematic evaluation. Symptomatic patients should undergo thorough investigation and vigilant observation for ARMD. Level IV, therapeutic study.
ERIC Educational Resources Information Center
Killingsworth, Erin Elizabeth
2013-01-01
With the widespread use of classroom exams in nursing education there is a great need for research on current practices in nursing education regarding this form of assessment. The purpose of this study was to explore how nursing faculty members make decisions about using best practices in classroom test construction, item analysis, and revision in…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-29
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. RM12-3-000] Revisions to Electric Quarterly Report Filing Process; Notice of Extended Availability of Sandbox Electronic Test Site Take notice that the opportunity to use the Sandbox Electronic Test Site (ETS) has been extended until September 15, 2013. The ETS including a web...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-19
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. RM12-3-000] Revisions to Electric Quarterly Report Filing Process; Notice of Availability of Sandbox Electronic Test Site Take notice that a Sandbox Electronic Test Site (ETS) and instructions have been posted on the Commission's Web site at http://www.ferc.gov/docs-filing...
What Is the Role for Patelloplasty With Gullwing Osteotomy in Revision TKA?
Gililland, Jeremy M; Swann, Presley; Pelt, Christopher E; Erickson, Jill; Hamad, Nadia; Peters, Christopher L
2016-01-01
Management of the patella in revision total knee arthroplasty (TKA) is challenging as a result of the deficient or unusable bone stock for patellar resurfacing that is frequently encountered. Options proposed in this setting include various patelloplasty procedures, patellectomy, and special patellar components. We sought to better define the role and results of one patelloplasty procedure, the gullwing osteotomy, used in revision TKA. (1) How much improvement in the outcome measures of range of motion and Knee Society scores was seen after revision TKA with a gullwing osteotomy? (2) What are the radiographic results of this osteotomy as judged by patellar healing and patellar tracking? (3) What complications are associated with the gullwing osteotomy in revision TKA? Between December 2003 and July 2012, we used a gullwing osteotomy on patients undergoing revision TKA (n = 238) in which the patellar remnant was avascular or less than 12 mm thick. This uncommon procedure was used in 17 of 115 (15%) of the patellae revised during this time. We performed manual chart reviews on all patients to collect preoperative and postoperative range of motion and Knee Society scores as well as radiographic review at last followup to assess patellar healing and tracking. In patients with at least 2 years of followup, the preoperative range of motion was a median -7.5° of extension (interquartile range [IQR], -15°-0°) and 90° of flexion (IQR, 90°-100°). Postoperative extension improved to 0° (IQR, 0°-0°; p = 0.015). With the numbers available, median flexion arc did not change at last followup (110°; IQR, 95°-120°; p = 0.674). The Knee Society score improved from a combined (clinical + functional) mean of 86 (95% confidence interval [CI], 56-116) preoperatively to 142 (95% CI, 121-163; p < 0.001) postoperatively. Radiographically, 12 of 13 patients demonstrated healing of the osteotomy with osseous union and one patient healed with a fibrous union. Nine of the 10 patients with at least 2 years of followup had a centrally tracking gullwing osteotomized patella at last followup. One patient, with just over 3 years of followup, exhibited lateral subluxation without evidence of fracture. Three of the 10 patients with greater than 2 years of followup developed recurrent infections. One patient had avascular necrosis with fragmentation of the patella at 4 months postoperatively. Patellar bone stock is often compromised in revision TKA, leaving the surgeon with very few options for reconstruction. Using this technique, we found acceptable function, no aseptic rerevisions for patellofemoral complications, nine of 10 of patellae tracking within the trochlear groove, and radiographic healing of the majority of the osteotomies. The gullwing osteotomy may be considered an option in these difficult revisions, but further studies with more complete followup are needed. Level IV, therapeutic study.
Mäntymäki, Heikki; Mäkelä, Keijo T; Vahlberg, Tero; Hirviniemi, Joni; Niinimäki, Tuukka
2016-09-01
Modern hip implants typically feature modular heads, which allow for easy exchange and removal from the femoral stem at the time of revision. However, owing to fretting, corrosion, or cold welding, the modular head may be difficult or impossible to separate from the underlying trunnion, especially if the implant has titanium interfaces between the head and the stem. We have repeatedly encountered difficulty removing the titanium sleeve adapter in the M(2)a-Magnum(TM) implant. Although the manufacturer warns about this complication and cases with these difficulties have been reported to the United States FDA, we believed this topic is important to study, because the frequency of difficulties in head removal is unknown and the complications related to this event have not been characterized. We asked: (1) Do revisions of M(2)a-Magnum(TM) implants differ from those of M(2)a-38(TM) implants in terms of ease of removal of the femoral head? (2) In cases where difficulty with M(2)a-Magnum(TM) head removal occurred, was the operative time, bleeding, risk of periprosthetic fracture, or joint infection increased compared with cases where the M(2)a-Magnum(TM) head was removed without difficulties? Between 2004 and 2014, we revised 296 THAs with metal-on-metal implants that involved M(2)a-Magnum(TM) (123) or M(2)a-38(TM) heads (88); of those, 84 were planned to include a femoral stem revision and insufficient data were available for three operations, so they were excluded from this analysis, leaving 124 THAs in the current retrospective study (70 THAs with M(2)a-Magnum(TM) and 54 THAs with M(2)a-38(TM) heads).The method of modular head removal, any difficulties removing the femoral head from the trunnion, operation time, and complications were recorded based on chart review. All the observed problems of detaching the head or taper adapter were among M(2)a-Magnum(TM) heads; there were no problems detaching the head in revisions of the M(2)a-38(TM) implant. In 29% (20 of 70) of revisions of the M(2)a-Magnum(TM) implant, the modular head could not be detached by knocking it with a punch and a mallet. Seventeen percent (12 of 70) of hips needed an unplanned stem revision owing to difficulties with head removal. In revisions of the M(2)a-Magnum(TM) implant that experienced head-removal problems, the median operative time was longer (144 minutes; range, 75-274 minutes) and bleeding was greater (725 mL; range, 300-2200 mL) compared with revisions of the M(2)a-Magnum(TM) implant without head removal problems (77 minutes, range, 33-197 minutes, p < 0.001; 475 mL, range, 50-1500 mL, p = 0.004). With the numbers available, we did not see differences in terms of the proportion of patients experiencing major complications (periprosthetic fracture or postoperative infections) between the groups (difficult versus easy; 25% [five of 20] versus 8% [four of 50]; odds ratio, 3.8 [95% CI, 0.9-16.2], p = 0.067). The titanium-titanium taper junction can be very difficult to separate during revision THAs, and if not anticipated, this problem can result in larger and more complicated revision procedures in patients who have the M(2)a-Magnum(TM) implant. Although the global use of metal-on-metal implants in THAs has decreased dramatically during the last several years, many thousands remain in service and therefore still might require revision. It is crucial to be prepared with special tools, including a femoral head extraction tool and diamond saw. The patient has to be informed of the possibility of a more extensive operation than preoperatively planned. Level III, therapeutic study.
Zhao, Jian; Schaser, Klaus-Dieter; Zhang, Feng
2010-05-01
To evaluate the surgical techniques and outcomes of revision surgery for compromised posterior stabilization or insufficient neurological decompression using anterior mini-open approach and expandable cage. From August 2005 to June 2008, a total of 235 patients were operated on in our center for thoracolumbar fractures with dorsal transpedicular stabilization. Twenty-six of these patients underwent revision surgery, the main reasons being back pain and stagnant neurological recovery. The surgical procedure comprised a single-level thoracolumbar corpectomy and/or canal clearance, followed by an expandable cage reconstruction. The average interval between primary and revision surgery was 5 months (range, 3-11 months). A transthoracic (n= 11) or transthoracic transdiaphragmatic (n= 15) mini-open approach was conducted using a table-mounted retractor. The operating time averaged 105 min (range, 95-135 min) for the transthoracic approach and 152 min (range, 120-190 min) for the transthoracic plus transdiaphragmatic approach. The overall mean blood loss was 780 ml (range, 550-1700 ml). Over time, the pre-operative neurological deficit improved in 6/7 patients by at least one Frankel/American Spinal Injury Association (ASIA) grade. On a visual analogue scale (VAS) from 0 to 10, the mean local thoracolumbar back pain was relieved significantly from 6.8 before operation to 3.8 at 3 months, 2.4 at 6 months, and 1.5 at 12 months postoperatively. None of the patients developed intercostal neuralgia or post-thoracotomy pain syndromes. For patients with compromised stabilization or insufficient neurological decompression after primary dorsal transpedicular stabilization for thoracolumbar fracture, anterior revision surgery can produce good results. The mini-open anterior approach for corpectomy in the thoracolumbar spine is safe, reliable, and economical. The expandable cage is an excellent alternative for anterior reconstruction. © 2010 Tianjin Hospital and Blackwell Publishing Asia Pty Ltd.
Liow, Ming Han Lincoln; Dimitriou, Dimitris; Tsai, Tsung-Yuan; Kwon, Young-Min
2016-12-01
Revision surgery of failed metal-on-metal (MoM) total hip arthroplasty (THA) for adverse tissue reaction (pseudotumor) can be challenging as a consequence of soft tissue and muscle necrosis. The aims of this study were to (1) report the revision outcomes of patients who underwent revision surgery for failed MoM hip arthroplasty due to symptomatic pseudotumor and (2) identify preoperative risk factors associated with revision outcomes. Between January 2011 and January 2013, a total of 102 consecutive large head MoM hip arthroplasties in 97 patients (male: 62, female: 35), who underwent revision surgery were identified from the database of a multidisciplinary referral center. At minimum follow-up of 2 years (range: 26-52 months), at least one complication had occurred in 14 of 102 revisions (14%). Prerevision radiographic loosening (P = .01), magnetic resonance imaging (MRI) findings of solid lesions with abductor deficiency on MRI (P < .001), and intraoperative grading of adverse tissue reactions (P = .05) were correlated with post-revision complications. The reoperation rate of revised MoM THA was 7% (7 of 102 hips). Implant survivorship was 88% at 3 years. Metal ion levels declined in most patients after removal of MoM articulation. Revision outcomes of revision surgery for failed MoM THA due to symptomatic pseudotumor demonstrated 14% complication rate and 7% re-revision rate at 30-month follow-up. Our study identified prerevision radiographic loosening, solid lesions/abductor deficiency on MRI, and high grade intraoperative tissue damage as risk factors associated with poorer revision outcomes. This provides clinically useful information for preoperative planning and perioperative counseling of MoM THA patients undergoing revision surgery. Copyright © 2016 Elsevier Inc. All rights reserved.
Lundman, Berit; Årestedt, Kristofer; Norberg, Astrid; Norberg, Catharina; Fischer, Regina Santamäki; Lövheim, Hugo
2015-01-01
This study tested the psychometric properties of a Swedish version of the Self-Transcendence Scale (STS). Cohen's weighted kappa, agreement, absolute reliability, relative reliability, and internal consistency were calculated, and the underlying structure of the STS was established by exploratory factor analysis. There were 2 samples available: 1 including 194 people aged 85-103 years and a convenience sample of 60 people aged 21-69 years. Weighted kappa values ranged from .40 to .89. The intraclass correlation coefficient for the original STS was .763, and the least significant change between repeated tests was 6.25 points. The revised STS was found to have satisfactory psychometric properties, and 2 of the 4 underlying dimensions in Reed's self-transcendence theory were supported.
Turner, Erlanger A
2012-08-01
The purpose of this paper is to provide psychometric data on the Parental Attitudes Toward Psychological Services Inventory (PATPSI), which is a revised measure to assess parents' attitudes toward outpatient mental health services. Using a sample of adults (N = 250), Study 1 supported a 3-factor structure (RMSEA = .05, NNFI = .94, and CFI = .94), adequate internal consistency (ranging from .72 to .92), and test-retest reliability (ranging from .66 to .84). Additionally, results indicated that individuals with previous use of mental health services reported more positive views toward child mental health services. Study 2 provided confirming evidence of the 3-factor structure (NNFI = .94, RMSEA = .08, and the CFI = .95) and adequate reliability (ranging from .70 to .90) using a parent-sample (N = 260). Additionally, discriminate validity of the PATPSI was supported. Implications for research and clinical practice are discussed.
Multidisciplinary assessment measure for individuals with disorders of consciousness.
Gollega, Ana; Meghji, Chamine; Renton, Sharon; Lazoruk, Arlene; Haynes, Elizabeth; Lawson, Denise; Ostapovitch, MaryAnne
2015-01-01
This study introduces the Comprehensive Assessment Measure for the Minimally Responsive Individual (CAMMRI) and reports on its development, inter-rater reliability, construct validity and clinical value. A multidisciplinary team of therapists developed this measure, which comprises 12 sub-tests that examine three main areas: Response to the Environment, Motor Control and Communication and Swallowing. The sub-tests are scored using a 7-point scale; sub-tests can also be administered individually. The measure was administered during a pilot project and then 1 year later to 12 adult clients with severe acquired brain injury at a long-term rehabilitation programme. The age range of the participants was 18-65 years; individuals were 1.5-10 years post-injury. Comparison measures included the Western Neuro Sensory Stimulation Profile (WNSSP), the Coma Recovery Scale-Revised (CRS-R) and the Chedoke McMaster Impairment Inventory (CMII). Inter-rater reliability of each sub-test ranged from 0.87-1.0, with an average of 0.90 in the first year of the assessments. Validity data supported the use of the CAMMRI for minimally conscious adults with ABI to measure behavioural changes and plan treatment for this population. Future research should focus on using this measure with other neurological populations.
ERIC Educational Resources Information Center
Boris, Ashley L.; Awadalla, Nardeen; Martin, Toby L.; Martin, Garry L.; Kaminski, Lauren; Miljkovic, Morena
2015-01-01
The Assessment of Basic Learning Abilities (ABLA) is a tool that is used to assess the learning ability of individuals with intellectual disability (ID) and children with autism. The ABLA was recently revised and is now referred to as the ABLA-Revised (ABLA-R). A self-instructional manual was prepared to teach individuals how to administer the…
Kearney, Paddy; Stafford, Bob; Gormley, Gerard J.; Crockard, Martin A.; Gilpin, Deirdre F.
2018-01-01
Background Urinary Tract Infections (UTIs) are common bacterial infections, second only to respiratory tract infections and particularly prevalent within primary care. Conventional detection of UTIs is culture, however, return of results can take between 24 and 72 hours. The introduction of a point of care (POC) test would allow for more timely identification of UTIs, facilitating improved, targeted treatment. This study aimed to obtain consensus on the criteria required for a POC UTI test, to meet patient need within primary care. Methods Criteria for consideration were compiled by the research team. These criteria were validated through a two-round Delphi process, utilising an expert panel of healthcare professionals from across Europe and United States of America. Using web-based questionnaires, panellists recorded their level of agreement with each criterion based on a 5-point Likert Scale, with space for comments. Using median response, interquartile range and comments provided, criteria were accepted/rejected/revised depending on pre-agreed cut-off scores. Results The first round questionnaire presented thirty-three criteria to the panel, of which 22 were accepted. Consensus was not achieved for the remaining 11 criteria. Following response review, one criterion was removed, while after revision, the remaining 10 criteria entered the second round. Of these, four were subsequently accepted, resulting in 26 criteria considered appropriate for a POC test to detect urinary infections. Conclusion This study generated an approved set of criteria for a POC test to detect urinary infections. Criteria acceptance and comments provided by the healthcare professionals also supports the development of a multiplex point of care UTI test. PMID:29879161
Relationship Between Metabolic Syndrome and Cognitive Abilities in U.S. Adolescents.
Rubens, Muni; Ramamoorthy, Venkataraghavan; Saxena, Anshul; George, Florence; Shehadeh, Nancy; Attonito, Jennifer; McCoy, H Virginia; Beck-Sagué, Consuelo M
2016-10-01
Metabolic syndrome is increasingly common in U.S. adolescents and has been linked to cognitive dysfunction. Purpose of this study is to explore associations between metabolic syndrome and cognitive impairment in U.S. adolescents using population-based data. Participants included adolescents aged 12-16 years who participated in the National Health and Nutrition Examination Survey (NHANES) III. The main outcome measures included assessments of cognitive function using Wide Range Achievement Test-Revised (WRAT-R) and Wechsler Intelligence Scale for Children-Revised (WISC-R) tools. The WRAT-R consisted of mathematics and reading tests. The WISC-R consisted of block design test, which measures spatial visualization and motor skills, and digit span test, which measures working memory and attention. Linear regression models were used to examine associations between metabolic syndrome and cognitive function. We used education levels of the family reference person, while controlling for education levels because of missing data. Presence or absence of metabolic syndrome was tested in 1170 of 2216 NHANES III participants aged 12-16 years. Regression models showed that participants with metabolic syndrome scored an average 1.25 [95% confidence interval (CI) = -2.14 to -0.36] points lower in reading examination and an average 0.89 (95% CI = -1.65 to -0.13) points lower in digit span examination, compared to those without metabolic syndrome. In addition, components of metabolic syndrome-elevated systolic blood pressure and increased waist circumference (WC)-were associated with impaired working memory/attention, and higher fasting glucose and increased WC were associated with poorer reading test scores. Metabolic syndrome was associated with impaired reading, working memory, and attention among adolescents.
3. "TEST STAND NO. 13, EXCAVATION PLAN & SECTIONS." Specifications ...
3. "TEST STAND NO. 1-3, EXCAVATION PLAN & SECTIONS." Specifications No. ENG 04-353-50-10; Drawing No. 60-0906; no sheet number within title block; D.O. SERIES 1109/10. Stamped: AS BUILT. No revisions or revision dates. Last work date on this drawing "Checked by EAG, 1/31/49." Though this drawing is specific to Test Stand 1-3, it also illustrates the general methods used for excavation design and retaining wall construction at Test Stand 1-5. - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Test Stand 1-3, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-06
... Business Park. More information on four translocated occurrences is discussed in the Geographic Range and.... The ESL was designed as an implementing tool for the City of San Diego Subarea Plan (City of San Diego... 2007, pers. comm.). At least four occurrences of M. viminea are believed to have been extirpated since...
DOT National Transportation Integrated Search
2013-01-01
This project consisted of the development of a revision of the SAE J2735 Dedicated Short Range Communications (DSRC) Message Set Dictionary, published 2009-11-19. This revision will be submitted, at the end of this project to the Society of Automotiv...
The Basic/Essential Skills Taxonomy. Second Edition--Revised.
ERIC Educational Resources Information Center
Snyder, Lester M., Jr.
This revision of the "Basic/Essential Skills Taxonomy" exhibits changes based on use of the original taxonomy in the field. It features more precise definitions of the levels of key words and phrases, the deletion of some science items that ranged above basic skills, the combination of the language arts sections from the original two parts, and…
A Psychometric Examination of English and Spanish Versions of the Revised Conflict Tactics Scales
ERIC Educational Resources Information Center
Connelly, Cynthia D.; Newton, Rae R.; Aarons, Gregory A.
2005-01-01
The psychometric properties of the Revised Conflict Tactics Scales (CTS2) are examined for English-speaking (n = 211) and Spanish-speaking (n = 194) Latino women. Internal consistency of total scale scores is satisfactory (Cronbach's alpha of .70 to .84). However, subscale alphas range from .46 to .80. Confirmatory factor analyses support five…
Interval Estimation of Revision Effect on Scale Reliability via Covariance Structure Modeling
ERIC Educational Resources Information Center
Raykov, Tenko
2009-01-01
A didactic discussion of a procedure for interval estimation of change in scale reliability due to revision is provided, which is developed within the framework of covariance structure modeling. The method yields ranges of plausible values for the population gain or loss in reliability of unidimensional composites, which results from deletion or…
Koskinen, Esa; Remes, Ville; Paavolainen, Pekka; Harilainen, Arsi; Sandelin, Jerker; Tallroth, Kaj; Kettunen, Jyrki; Ylinen, Pekka
2011-06-01
The objectives of the present study were to find out the results and the factors affecting survival after primary knee arthroplasty with a cruciate-retaining prosthesis in severe valgus deformity. Forty-eight patients (52 knees) participated in the current follow-up study. All patients were followed at least 5 years or to first revision. Mean follow-up time was 9 years (range, 1 to 17 years).The Kaplan-Meier analysis revealed 79% (95% CI 68% to 91%) survival rate with revision for any reason and 81% (95% CI 70% to 93%) survival rate with revision for instability as an endpoint at 10 years. Preoperatively TFA was 23° (range, 15°-51°) in valgus and 7° (range, 21° valgus-4° varus) in valgus postoperatively. Of the 14 re-operated patients, eight were revised because of progressive postoperative medial collateral ligament instability. All re-operations were performed during the first 4 years of the follow-up. The mean TFA was 15.5° valgus postoperatively for those eight and the odds ratio for a revision was 2 (95% CI 1-3, p = 0.025) when compared to the rest of the study population. The residual valgus deformity increases the risk of re-operation and it should be avoided. If proper soft-tissue balance cannot be achieved or there is no functional medial collateral ligament present more constrained implants should be used. In selected cases where both bony correction and ligament balancing have properly been achieved the use of a cruciate-retaining type of prosthesis is justified. Copyright © 2010 Elsevier B.V. All rights reserved.
Delta's Key to the TOEFL iBT[R]: Advanced Skill Practice. Revised Edition
ERIC Educational Resources Information Center
Gallagher, Nancy
2012-01-01
Delta's Key to the TOEFL iBT: Advanced Skill Practice is a revised and updated edition of Delta's Key to the Next Generation TOEFL Test. Since the introduction of the TOEFL iBT in 2005, there have been significant changes to some of the test questions, particularly the integrated writing and integrated speaking tasks. The new 2011 edition of…
Rasch Modeling of Revised Token Test Performance: Validity and Sensitivity to Change
ERIC Educational Resources Information Center
Hula, William; Doyle, Patrick J.; McNeil, Malcolm R.; Mikolic, Joseph M.
2006-01-01
The purpose of this research was to examine the validity of the 55-item Revised Token Test (RTT) and to compare traditional and Rasch-based scores in their ability to detect group differences and change over time. The 55-item RTT was administered to 108 left- and right-hemisphere stroke survivors, and the data were submitted to Rasch analysis.…
Ten Hoor, Gill; Hoebe, Christian Jpa; van Bergen, Jan Eam; Brouwers, Elfi Ehg; Ruiter, Robert Ac; Kok, Gerjo
2014-01-30
In The Netherlands, screening for chlamydia (the most prevalent sexually transmitted infection worldwide) is a relatively simple and free procedure. Via an invitation letter sent by the public health services (PHS), people are asked to visit a website to request a test kit. They can then do a chlamydia test at home, send it anonymously to a laboratory, and, within two weeks, they can review their test results online and be treated by their general practitioner or the PHS. Unfortunately, the participation rates are low and the process is believed to be not (cost-) effective. The objective of this study was to assess whether the low participation rate of screening for chlamydia at home, via an invitation letter asking to visit a website and request a test kit, could be improved by optimizing the invitation letter through systematically applied behavior change theories and evidence. The original letter and a revised letter were randomly sent out to 13,551 citizens, 16 to 29 years old, in a Dutch municipality. Using behavior change theories, the revised letter sought to increase motivation to conduct chlamydia screening tests. The revised letter was tailored to beliefs that were found in earlier studies: risk perception, advantages and disadvantages (attitude), moral norm, social influence, and response- and self-efficacy. Revisions to the new letter also sought to avoid possible unwanted resistance caused when people feel pressured, and included prompts to trigger the desired behavior. No significant differences in test package requests were found between the two letters. There were also no differences between the original and revised letters in the rates of returned tests (11.80%, 581/4922 vs. 11.07%, 549/4961) or positive test results (4.8%, 23/484 vs. 4.1%, 19/460). It is evident that the new letter did not improve participation compared to the original letter. It is clear that the approach of inviting the target population through a letter does not lead to higher participation rates for chlamydia screening. Other approaches have to be developed and pilot tested.
Ramsey, Danielle; Scoto, Mariacristina; Mayhew, Anna; Main, Marion; Mazzone, Elena S; Montes, Jacqueline; de Sanctis, Roberto; Dunaway Young, Sally; Salazar, Rachel; Glanzman, Allan M; Pasternak, Amy; Quigley, Janet; Mirek, Elizabeth; Duong, Tina; Gee, Richard; Civitello, Matthew; Tennekoon, Gihan; Pane, Marika; Pera, Maria Carmela; Bushby, Kate; Day, John; Darras, Basil T; De Vivo, Darryl; Finkel, Richard; Mercuri, Eugenio; Muntoni, Francesco
2017-01-01
Recent translational research developments in Spinal Muscular Atrophy (SMA), outcome measure design and demands from regulatory authorities require that clinical outcome assessments are 'fit for purpose'. An international collaboration (SMA REACH UK, Italian SMA Network and PNCRN USA) undertook an iterative process to address discontinuity in the recorded performance of the Hammersmith Functional Motor Scale Expanded and developed a revised functional scale using Rasch analysis, traditional psychometric techniques and the application of clinical sensibility via expert panels. Specifically, we intended to develop a psychometrically and clinically robust functional clinician rated outcome measure to assess physical abilities in weak SMA type 2 through to strong ambulant SMA type 3 patients. The final scale, the Revised Hammersmith Scale (RHS) for SMA, consisting of 36 items and two timed tests, was piloted in 138 patients with type 2 and 3 SMA in an observational cross-sectional multi-centre study across the three national networks. Rasch analysis demonstrated very good fit of all 36 items to the construct of motor performance, good reliability with a high Person Separation Index PSI 0.98, logical and hierarchical scoring in 27/36 items and excellent targeting with minimal ceiling. The RHS differentiated between clinically different groups: SMA type, World Health Organisation (WHO) categories, ambulatory status, and SMA type combined with ambulatory status (all p < 0.001). Construct and concurrent validity was also confirmed with a strong significant positive correlation with the WHO motor milestones rs = 0.860, p < 0.001. We conclude that the RHS is a psychometrically sound and versatile clinical outcome assessment to test the broad range of physical abilities of patients with type 2 and 3 SMA. Further longitudinal testing of the scale with regards change in scores over 6 and 12 months are required prior to its adoption in clinical trials.
Feldacker, Caryl; Chicumbe, Sergio; Dgedge, Martinho; Cesar, Freide; Augusto, Gerito; Robertson, Molly; Mbofana, Francisco; O'Malley, Gabrielle
2015-04-16
Mozambique suffers from critical shortages of healthcare workers including non-physician clinicians, Tecnicos de Medicina Geral (TMGs), who are often senior clinicians in rural health centres. The Mozambique Ministry of Health and the International Training and Education Center for Health, University of Washington, Seattle, revised the national curriculum to improve TMG clinical knowledge and skills. To evaluate the effort, data was collected at graduation and 10 months later from pre-revision (initial) and revised curriculum TMGs to determine the following: (1) Did cohorts trained in the revised curriculum score higher on measurements of clinical knowledge, physical exam procedures, and solving clinical case scenarios than those trained in the initial curriculum; (2) Did TMGs in both curricula retain their knowledge over time (from baseline to follow-up); and (3) Did skills and knowledge retention differ over time by curricula? Post-graduation and over time results are presented. t-tests examine differences in scores between curriculum groups. Univariate and multivariate linear regression models assess curriculum-related, demographic, and workplace factors associated with scores on each of three evaluation methods at the p < 0.05 level. Paired t-tests examine within-group changes over time. ANOVA models explore differences between Health Training Institutes (HTIs). Generalized estimating equations determine whether change in scores over time differed by curricula. Mean scores of initial curriculum TMGs at follow-up were 52.7%, 62.6%, and 40.0% on the clinical cases, knowledge test, and physical exam, respectively. Averages were significantly higher among the revised group for clinical cases (60.2%; p < 0.001) and physical exam (47.6%; p < 0.001). HTI was influential on clinical case and physical exam scores. Between graduation and follow-up, clinical case and physical exam scores decreased significantly for initial curriculum students; clinical case scores increased significantly among revised curriculum TMGs. Although curriculum revision had limited effect, marginal improvements in the revised group show promise that these TMGs may have increased ability to synthesize clinical information. Weaknesses in curriculum and practicum implementation likely compromised the effect of curriculum revision. An improvement strategy that includes strengthened TMG training, greater attention to pre-service clinical practice, and post-graduation mentoring may be more advantageous than curriculum revision, alone, to improve care provided by TMGs.
Hernigou, Philippe; Dubory, Arnaud; Potage, Damien; Roubineau, François; Flouzat-Lachaniette, Charles Henri
2017-04-01
Patients with rheumatoid arthritis (RA) and osteoarthritis (OA) may require revision total knee replacement. Few studies have compared post-operative complications, results and risk of re-revision in RA and OA patients. Forty-five RA patients who had undergone revision TKA from 1998 to 2010 were selected and matched with 45 OA patients who had revision during the same period. Results of the use of a revision postero-stabilized implant in osteoarthritis were compared to results of its use in inflammatory arthritis. With a mean follow-up of ten years (range, 5-17 years) we determined differences in comorbidities, risk for peri-operative adverse events, functional and radiological results, and risk of subsequent re-revision, between patients suffering from OA versus RA. There were higher comorbidities, post-operative (<30 days) adverse events, and mortality at average ten years FU in RA than in OA patients. The mean overall changes in function scores were greater for the RA revision group when compared with the OA revision group. Taking steroids (Cox's regression, p = 0.001), and methotrexate or TNFα blockers (Cox's regression, p = 0.02) were not significant factors for radiolucent lines in RA and for loosening. At average ten years followup, patients with RA undergoing revision TKAs were not more likely to have a re-revision (4 among 45 patients; 9 %) than patients with OA undergoing revision in our department (7 patients; 15 %). Similar results for the knee were observed in these two forms of arthritis in spite of the fact that the initial local joint status and general health status are worse in inflammatory rheumatoid arthritis than in "degenerative" osteoarthritis. However, complications were more frequent with RA.
Fan, Yijun; Huang, Zhaohui; Zhang, Dazhao; Chang, Jun; Jia, Yun; He, Shuihong; Wei, Bing
2017-08-01
The aim of this study was to examine the reliability and validity of the Illness Perception Questionnaire-Revised (IPQ-R) in patients with stress urinary incontinence (SUI). A total of 256 patients with SUI and 76 patients with myoma of the uterus were recruited to complete the Chinese IPQ-R. For the reliability, the key tests included Cronbach's α coefficient and intraclass correlation coefficients. For the validity, the key tests included factor analysis, Spearman's correlation coefficient, and the Student's t-test. Cronbach's α values ranged from 0.68 to 0.90 for each subscale and the intraclass correlation coefficients ranged from 0.80 to 0.94. The results of the confirmatory factor analysis showed that the seven-factor structure as proposed by the original IPQ-R fit the data poorly. Although removal of three items improved the model's fit, the goodness-of-fit statistics were still below acceptable standards. We identified an acceptable seven-factor solution from the 38 items on Illness Beliefs using an exploratory factor analysis (EFA), which accounted for 68.12% of the variance. For the concurrent validity, Consequences and Emotional Representation both had good correlations with anxiety and depression (r = 0.52-0.62) and better quality of life (r = 0.58-0.73). The inter-correlation coefficient of the seven factors ranged from 0.05 to 0.59, suggesting acceptable discriminant validity. There were significant differences on the scale scores of Disease Identity (t = 9.39, P < 0.01), Timeline-Acute/Chronic (t = 3.69, P < 0.01), Consequences (t = 4.53, P < 0.01), Illness Coherence (t = 7.73, P < 0.01), Timeline-Cyclical (t = 6.48, P < 0.01), Emotional Representation (t = 6.40, P < 0.01), and Cause (t = 4.29, P < 0.01) between the patients with SUI and with myoma of the uterus, which also indicated acceptable discriminant validity. The findings of this study supported the Chinese IPQ-R as being a reliable and valid tool for measuring illness perception among patients with SUI. © 2017 Japan Society of Obstetrics and Gynecology.
The Cloud Feedback Model Intercomparison Project Observational Simulator Package: Version 2
NASA Astrophysics Data System (ADS)
Swales, Dustin J.; Pincus, Robert; Bodas-Salcedo, Alejandro
2018-01-01
The Cloud Feedback Model Intercomparison Project Observational Simulator Package (COSP) gathers together a collection of observation proxies or satellite simulators
that translate model-simulated cloud properties to synthetic observations as would be obtained by a range of satellite observing systems. This paper introduces COSP2, an evolution focusing on more explicit and consistent separation between host model, coupling infrastructure, and individual observing proxies. Revisions also enhance flexibility by allowing for model-specific representation of sub-grid-scale cloudiness, provide greater clarity by clearly separating tasks, support greater use of shared code and data including shared inputs across simulators, and follow more uniform software standards to simplify implementation across a wide range of platforms. The complete package including a testing suite is freely available.
Ustün, B; Compton, W; Mager, D; Babor, T; Baiyewu, O; Chatterji, S; Cottler, L; Göğüş, A; Mavreas, V; Peters, L; Pull, C; Saunders, J; Smeets, R; Stipec, M R; Vrasti, R; Hasin, D; Room, R; Van den Brink, W; Regier, D; Blaine, J; Grant, B F; Sartorius, N
1997-09-25
The WHO Study on the reliability and validity of the alcohol and drug use disorder instruments in an international study which has taken place in centres in ten countries, aiming to test the reliability and validity of three diagnostic instruments for alcohol and drug use disorders: the Composite International Diagnostic Interview (CIDI), the Schedules for Clinical Assessment in Neuropsychiatry (SCAN) and a special version of the Alcohol Use Disorder and Associated Disabilities Interview schedule-alcohol/drug-revised (AUDADIS-ADR). The purpose of the reliability and validity (R&V) study is to further develop the alcohol and drug sections of these instruments so that a range of substance-related diagnoses can be made in a systematic, consistent, and reliable way. The study focuses on new criteria proposed in the tenth revision of the International Classification of Diseases (ICD-10) and the fourth revision of the diagnostic and statistical manual of mental disorders (DSM-IV) for dependence, harmful use and abuse categories for alcohol and psychoactive substance use disorders. A systematic study including a scientifically rigorous measure of reliability (i.e. 1 week test-retest reliability) and validity (i.e. comparison between clinical and non-clinical measures) has been undertaken. Results have yielded useful information on reliability and validity of these instruments at diagnosis, criteria and question level. Overall the diagnostic concordance coefficients (kappa, kappa) were very good for dependence disorders (0.7-0.9), but were somewhat lower for the abuse and harmful use categories. The comparisons among instruments and independent clinical evaluations and debriefing interviews gave important information about possible sources of unreliability, and provided useful clues on the applicability and consistency of nosological concepts across cultures.
Normative data for the Words-in-Noise Test for 6- to 12-year-old children.
Wilson, Richard H; Farmer, Nicole M; Gandhi, Avni; Shelburne, Emily; Weaver, Jamie
2010-10-01
To establish normative data for children on the Words-in-Noise Test (WIN; R. H. Wilson, 2003; R. H. Wilson & R. McArdle, 2007). Forty-two children in each of 7 age groups, ranging in age from 6 to 12 years (n=294), and 24 young adults (age range: 18-27 years) with normal hearing for pure tones participated. All listeners were screened at 15 dB HL (American National Standards Institute, 2004) with the octave interval between 500 and 4000 Hz. Randomizations of WIN Lists 1, 2, and 1 or WIN Lists 2, 1, and 2 were presented with the noise fixed at 70 dB SPL, followed by presentation at 90 dB SPL of the 70 Northwestern University Auditory Test No. 6 (T. W. Tillman & R. Carhart, 1966) words used in the WIN. Finally, the Peabody Picture Vocabulary Test-Revised (L. M. Dunn & L. M. Dunn, 1981) was administered. Testing was conducted in a quiet room. There were 3 main findings: (a) The biggest change in recognition performance occurred between the ages of 6 and 7 years; (b) from 9 to 12 years, recognition performance was stable; and (c) performance by young adults (18-27 years) was slightly better (1-2 dB) than performance by the older children. The WIN can be used with children as young as 6 years of age; however, age-specific ranges of normal recognition performance must be used.
[The internationalization of the nursing profession in Taiwan].
Chuang, Hsiao-Ling; Wang, Cheng-Ching; Kuo, Pi-Chao
2011-06-01
Globalization, nursing manpower migration, and the multinational nature of the medical industry have increased the level of internationalization in Taiwan's nursing profession. In nursing practice, competencies for the general nursing list (Taiwan version) and ICNP (International Classification for Nursing Practice) have been clinically tested and revised. In academic nursing, significant effort is invested toward achieving the three general objectives of internationalized teaching, internationalized campuses, and international academic exchanges. We should further test and revise Taiwan's competencies for the general nursing list, and the ICNP should be continually tested and revised. Additionally, nursing personnel should strengthen foreign language competencies, appreciate different nursing practice cultures, participate in international exchange activities, and place increasing emphasis on international cooperation in research and nursing education accreditation. Such should further enhance and strengthen international cooperation, which should further encourage internationalization in the domestic nursing profession.
Sankey, Eric W; Goodwin, C Rory; Jusué-Torres, Ignacio; Elder, Benjamin D; Hoffberger, Jamie; Lu, Jennifer; Blitz, Ari M; Rigamonti, Daniele
2016-05-01
OBJECT Endoscopic third ventriculostomy (ETV) is the treatment of choice for obstructive hydrocephalus; however, the success of ETV in patients who have previously undergone shunt placement remains unclear. The present study analyzed 103 adult patients with aqueductal stenosis who underwent ETV for obstructive hydrocephalus and evaluated the effect of previous shunt placement on post-ETV outcomes. METHODS This study was a retrospective review of 151 consecutive patients who were treated between 2007 and 2013 with ETV for hydrocephalus. One hundred three (68.2%) patients with aqueductal stenosis causing obstructive hydrocephalus were included in the analysis. Postoperative ETV patency and aqueductal and cisternal flow were assessed by high-resolution, gradient-echo MRI. Post-ETV Mini-Mental State Examination, Timed Up and Go, and Tinetti scores were compared with preoperative values. Univariate and multivariate analyses were performed comparing the post-ETV outcomes in patients who underwent a primary (no previous shunt) ETV (n = 64) versus secondary (previous shunt) ETV (n = 39). RESULTS The majority of patients showed significant improvement in symptoms after ETV; however, no significant differences were seen in any of the quantitative tests performed during follow-up. Symptom recurrence occurred in 29 (28.2%) patients after ETV, after a median of 3.0 (interquartile range 0.8-8.0) months post-ETV failure. Twenty-seven (26.2%) patients required surgical revision after their initial ETV. Patients who received a secondary ETV had higher rates of symptom recurrence (p = 0.003) and surgical revision (p = 0.003), particularly in regard to additional shunt placement/revision post-ETV (p = 0.005). These differences remained significant after multivariate analysis for both symptom recurrence (p = 0.030) and surgical revision (p = 0.043). CONCLUSIONS Patients with obstructive hydrocephalus due to aqueductal stenosis exhibit symptomatic improvement after ETV, with a relatively low failure rate. Patients with a primary history of shunt placement who undergo ETV as a secondary intervention are at increased risk of symptom recurrence and need for surgical revision post-ETV.
Fania, Claudio; Albertini, Federica; Palatini, Paolo
2017-10-01
The aim of this study was to define the accuracy of UM-211, an automated oscillometric device for office use coupled to several cuffs for different arm sizes, according to the International Protocol of the European Society of Hypertension. The validation was performed in 33 individuals. Their mean age was 59.6±12.9 years, systolic blood pressure (BP) was 144.3±21.5 mmHg (range: 96-184 mmHg), diastolic BP was 86.8±18.5 mmHg (range: 48-124 mmHg), and arm circumference was 30.2±4.3 cm (range: 23-39 cm). Four sequential readings were taken by observers 1 and 2 using a double-headed stethoscope and a mercury sphygmomanometer, whereas three BP readings were taken by the supervisor using the test instrument. The differences between the readings provided by the device and the mean observer measurements were calculated. Therefore, each device measurement was compared with the previous and the next mean observer measurement. The validation results fulfilled all the 2010 European Society of Hypertension revision Protocol criteria for the general population and passed all validation grades. On average, the device overestimated systolic BP by 1.7±2.4 mmHg and diastolic BP by 1.7±2.5 mmHg. These data show that the UM-211 device coupled to several cuffs for different ranges of arm circumference met the requirements for validation according to the International Protocol and can be recommended for clinical use in the adult population. However, these results mainly apply to the use of the 22-32 and the 31-45 cm cuffs.
Louis, M-L; D'ingrado, P; Ehkirch, F P; Bertiaux, S; Colombet, P; Sonnery-Cottet, B; Schlatterer, B; Pailhé, R; Panisset, J C; Steltzlen, C; Lustig, S; Lutz, C; Dalmay, F; Imbert, P; Saragaglia, D
2017-12-01
A careful analysis of the reasons for ACL reconstruction failure is essential to selection of the optimal surgical revision technique designed to ensure good rotational stability and to minimise the risk of re-rupture. To evaluate anterolateral ligament (ALL) stabilisation during revision ACL reconstruction. ALL stabilisation during revision ACL reconstruction provides good rotational stability without increasing the risk of complications. This multicentre study included 349 patients, 151 retrospectively and 198 prospectively. There were 283 males and 66 females. Inclusion criteria were an indication for revision ACL reconstruction surgery with combined intra-articular reconstruction and ALL stabilisation after failed autograft ACL reconstruction, and intact PCL. Exclusion criteria were primary ACL reconstruction and concomitant peripheral medial and/or lateral lesions. Each patient underwent a clinical and radiographic evaluation before and after revision surgery. Before revision surgery, the mean IKDC score was 56.5±15.5 and 96% of patients were IKDC C or D. Rates were 5.0% for early and 10.5% for late postoperative complications. Lachmann's test had a hard stop at last follow-up in 97% of patients. The pivot-shift test was positive in 1% of patients. The mean subjective IKDC score was 84.5±13.0 and 86.5% of patients were IKDC A or B. The proportions of patients with radiographic knee osteoarthritis at last follow-up was unchanged for the lateral tibio-femoral and patello-femoral compartments but increased by 9.7% to 21.2% for the medial tibio-femoral compartment. The re-rupture rate was 1.2% and the further surgical revision rate was 5.4%. Anterior laxity at last follow-up was consistent with previous studies of revision ACL reconstruction. However, rotational stability and the re-rupture risk were improved. ALL stabilisation is among the techniques that deserve consideration as part of the therapeutic options for revision ACL reconstruction. IV, retrospective and prospective cohort study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
McCollum, Rosalind; Otiso, Lilian; Mireku, Maryline; Theobald, Sally; de Koning, Korrie; Hussein, Salim; Taegtmeyer, Miriam
2016-02-01
Global interest and investment in close-to-community health services is increasing. Kenya is currently revising its community health strategy (CHS) alongside political devolution, which will result in revisioning of responsibility for local services. This article aims to explore drivers of policy change from key informant perspectives and to study perceptions of current community health services from community and sub-county levels, including perceptions of what is and what is not working well. It highlights implications for managing policy change. We conducted 40 in-depth interviews and 10 focus group discussions with a range of participants to capture plural perspectives, including those who will influence or be influenced by CHS policy change in Kenya (policymakers, sub-county health management teams, facility managers, community health extension worker (CHEW), community health workers (CHWs), clients and community members) in two purposively selected counties: Nairobi and Kitui. Qualitative data were digitally recorded, transcribed, translated and coded before framework analysis. There is widespread community appreciation for the existing strategy. High attrition, lack of accountability for voluntary CHWs and lack of funds to pay CHW salaries, combined with high CHEW workload were seen as main drivers for strategy change. Areas for change identified include: lack of clear supervisory structure including provision of adequate travel resources, current uneven coverage and equity of community health services, limited community knowledge about the strategy revision and demand for home-based HIV testing and counselling. This in-depth analysis which captures multiple perspectives results in robust recommendations for strategy revision informed by the Five Wonders of Change Framework. These recommendations point towards a more people-centred health system for improved equity and effectiveness and indicate priority areas for action if success of policy change through the roll-out of the revised strategy is to be realized. © The Author 2015. Published by Oxford University Press in association with The London School of Hygiene and Tropical Medicine.
Shamsudin, Aminudin; Lam, Patrick H; Peters, Karin; Rubenis, Imants; Hackett, Lisa; Murrell, George A C
2015-03-01
Symptomatic rotator cuff tears are often treated surgically. However, there is a paucity of information regarding the outcomes of revision arthroscopic rotator cuff repairs. To evaluate the outcome of revision arthroscopic rotator cuff surgery when compared with primary arthroscopic rotator cuff surgery in a large cohort of patients. Cohort study; Level of evidence, 3. A consecutive series of 50 revision arthroscopic rotator cuff repairs performed by a single surgeon, with minimum 2-year follow-up, were retrospectively reviewed using prospectively collected data. As a comparison, 3 primary arthroscopic rotator cuff repair cases (primary group; n = 310) were chosen immediately before each revision case, and 3 were chosen after. Standardized patient-ranked outcomes, examiner-determined assessments, and ultrasound-determined rotator cuff integrity were assessed preoperatively at 6 months and at a minimum of 2 years after surgery. The revision group was older (mean age, 63 years; range, 43-80 years) compared with the primary group (mean age, 60 years; range, 18-88 years) (P < .05) and had larger tear size (mean ± SEM) (4.1 ± 0.5 cm(2)) compared with the primary group (3.0 ± 0.2 cm(2)) (P < .05). Two years after surgery, the primary group reported less pain at rest (P < .02), during sleep (P < .05), and with overhead activity (P < .01) compared with the revision group. The primary group had better passive forward flexion (+13°; P < .05), abduction (+18°; P < .01), internal rotation (+2 vertebral levels; P < .001) and also significantly greater supraspinatus strength (+15 N; P < .001), lift-off strength (+9.3 N; P < .05), and adduction strength (+20 N; P < .01) compared with the revision group at 2 years. When compared with the primary group, the revision group was more satisfied with the overall shoulder function before surgery but was less satisfied with their shoulder function than the primary group at 2 years (P < .005). The retear rate for primary rotator cuff repair was 16% at 6 months and 21% at 2 years, while the retear rate for revision rotator cuff repair was 28% at 6 months and deteriorated to 40% at 2 years (P < .05). The short-term clinical outcomes of patients undergoing revision rotator cuff repair were similar to those after primary rotator cuff repair. However, these results did not persist, and by 2 years patients who had revision rotator cuff repair were twice as likely to have retorn compared with those undergoing primary repair. The increase in retear rate in the revision group at 2 years was associated with increased pain, impaired overhead function, less passive motion, weaker strength, and less overall satisfaction with shoulder function. © 2014 The Author(s).
Psychometric Properties of the Revised Developmental Coordination Disorder Questionnaire
ERIC Educational Resources Information Center
Wilson, Brenda N.; Crawford, Susan G.; Green, Dido; Roberts, Gwen; Aylott, Alice; Kaplan, Bonnie J.
2009-01-01
The Developmental Coordination Disorder Questionnaire (DCDQ) is a parent-completed measure designed to identify subtle motor problems in children of 8 to 14.6 years of age. The purpose of this study was to extend the lower age range to children aged 5 to 7 years, revise items to ensure clarity, develop new scoring, and evaluate validity of the…
Aerodynamic Characteristics of a Revised Target Drone Vehicle at Mach Numbers from 1.60 to 2.86
NASA Technical Reports Server (NTRS)
Blair, A. B., Jr.; Babb, C. Donald
1968-01-01
An investigation has been conducted in the Langley Unitary Plan wind tunnel to determine the aerodynamic characteristics of a revised target drone vehicle through a Mach number range from 1.60 to 2.86. The vehicle had canard surfaces and a swept clipped-delta wing with twin tip-mounted vertical tails.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-03-01
...- ranging populations of muscovy ducks present as the result of human activity. For example, one State was... species. We propose to revise 50 CFR 21.14 to prohibit sale and, in most cases, possession, of muscovy... following issues. Issue. One commenter suggested that Cameron County, Texas not be included in the natural...
The Representation of Women in a Sample of Post-1994 South African School History Textbooks
ERIC Educational Resources Information Center
Schoeman, Sonja
2009-01-01
History curriculum revisions post 1994 were followed by a range of new History textbooks intended to meet the needs of teachers seeking to implement the revised curriculum. I sought to establish whether or not a sample of these textbooks had built upon the gender equality initiatives introduced after 1994. A qualitative intrinsic case study was…
Yamazaki, Kentaro; Taniguchi, Hiroya; Yoshino, Takayuki; Akagi, Kiwamu; Ishida, Hideyuki; Ebi, Hiromichi; Nakatani, Kaname; Muro, Kei; Yatabe, Yasushi; Yamaguchi, Kensei; Tsuchihara, Katsuya
2018-06-01
The Japanese Society of Medical Oncology (JSMO) previously published 2 editions of the clinical guidelines: "Japanese guidelines for testing of KRAS gene mutation in colorectal cancer" in 2008 and "Japanese Society of Medical Oncology Clinical Guidelines: RAS (KRAS/NRAS) mutation testing in colorectal cancer patients" in 2014. These guidelines have contributed to the proper use of KRAS and RAS mutation testing, respectively. Recently, clinical utility, particularly for colorectal cancer (CRC) patients with BRAF V600E mutation or DNA mismatch-repair (MMR) deficiency, has been established. Therefore, the guideline members decided these genetic alterations should also be involved. The aim of this revision is to properly carry out testing for BRAF V600E mutation and MMR deficiency in addition to RAS mutation. The revised guidelines include the basic requirements for testing for these genetic alterations based on recent scientific evidence. Furthermore, because clinical utility of comprehensive genetic testing using next-generation sequencing and somatic gene testing of analyzing circulating tumor DNA has increasingly evolved with recent advancements in testing technology, we noted the current situation and prospects for these testing technologies and their clinical implementation in the revised guidelines. © 2018 The Authors. Cancer Science published by John Wiley & Sons Australia, Ltd on behalf of Japanese Cancer Association.
Mc Gee, Shauna L; Höltge, Jan; Maercker, Andreas; Thoma, Myriam V
2017-08-11
The present study evaluated the revised Sense of Coherence (SOC-R) scale in a sample of older adults, using an extended range of psychological concepts. It further examined the psychometric properties of the revised scale and tested the theoretical assumptions underpinning the SOC-R concept. The SOC-R scale was evaluated in 268 Swiss older adults (mean age = 66.9 years), including n = 15 heavily traumatized former indentured child labourers. Standardised questionnaires collected information on positive and negative life experiences, resources, current health, and well-being. Results: Confirmatory Factor Analysis indicated good model fit for a second-order three-factor model of SOC-R with the factors manageability, balance, and reflection. Satisfactory convergent and discriminant correlations were shown with related psychological concepts, including neuroticism (r = -.32, p < .01), optimism (r = .31, p < .01), and general self-efficacy (r = .49, p < .01). SOC-R was not observed to differ by age group. Moderation analyses indicated that SOC-R moderated the relationship between certain early-life adversities and mental health. The study provides support for the psychometric properties and theoretical assumptions of SOC-R and suggests that SOC-R is a valid and reliable measure suitable for use with older adults. Future studies should employ longitudinal designs to examine the stability of SOC-R.
Designing Critique for Knowledge Integration
NASA Astrophysics Data System (ADS)
Sato, Mie Elissa
Generating explanations is central to science and has the potential to have a powerful impact on students' conceptual understanding in science instruction. However, improving conceptual understanding by generating explanations is a fraught affair: students may struggle with the sense of false clarity that may arise from generating explanations, fail to detect gaps in their understanding, and dismiss salient information that contradict their beliefs. Critiquing explanations has the potential to counteract these pitfalls by exposing students to alternative ideas to contrast with their own. This dissertation seeks to clarify how to design critique in technology-enhanced science instruction to support students in revising their explanations about scientific phenomena, and in doing so, refining their conceptual understanding. Using the Knowledge Integration framework, I revised two technology-enhanced curriculum units, Plate Tectonics and Global Climate Change, in a design partnership between teachers, researchers, and technologists. I conducted a series of studies with sixth-grade students to investigate the conditions under which guided critique of explanations can support revision. The pilot critique study investigated the impact of the revised Plate Tectonics unit on students' understanding of convection, as well as of a preliminary design of critique where students generated and applied their own criteria for what makes a good explanation in science. The guidance study explored how incorporating a complex selection task that features meta-explanatory criteria into critique supports students in distinguishing among different criteria, as well as how students use peer or expert guidance on their initial explanation during revision. The critique study investigated how designing critique with a complex selection task that features plausible alternative ideas and giving guidance on students' critiques support students in distinguishing among a range of relevant ideas and making productive revisions to their initial explanations. These studies clarify how critique can be designed to help students sort through various ideas in their conceptual repertoire, be they ideas about meta-explanatory criteria or science ideas about a specific phenomenon. The study findings illuminate the challenges of guiding students to examine or re-examine the full range of ideas for knowledge integration. Students struggle to identify salient, missing, or normative ideas in their own or another explanation, and to incorporate their insights in a coherent way through revision. The studies demonstrate that embedding complex selection tasks in critique encourages students to consider a broad range of ideas and supports them in making conceptual revisions of their explanations. The results have implications for the design of critique in technology-enhanced science instruction.
Personality and Bulimic Symptomatology.
ERIC Educational Resources Information Center
Janzen, B. L.; And Others
1993-01-01
Examined relationship between bulimic symptomatology as measured by scores on Bulimia Test-Revised (BULIT-R) and personality characteristics based on Eysenck Personality Questionnaire-Revised in nonclinical sample of 166 female college students. Obtained relationship between Neuroticism, Addictiveness and scores on BULIT-R. (Author/NB)
ERIC Educational Resources Information Center
Attali, Yigal; Powers, Don; Hawthorn, John
2008-01-01
Registered examinees for the GRE® General Test answered open-ended sentence-completion items. For half of the items, participants received immediate feedback on the correctness of their answers and up to two opportunities to revise their answers. A significant feedback-and-revision effect was found. Participants were able to correct many of their…
Triple-α reaction rate constrained by stellar evolution models
NASA Astrophysics Data System (ADS)
Suda, Takuma; Hirschi, Raphael; Fujimoto, Masayuki Y.
2012-11-01
We investigate the quantitative constraint on the triple-α reaction rate based on stellar evolution theory, motivated by the recent significant revision of the rate proposed by nuclear physics calculations. Targeted stellar models were computed in order to investigate the impact of that rate in the mass range of 0.8<=M/Msolar<=25 and in the metallicity range between Z = 0 and Z = 0.02. The revised rate has a significant impact on the evolution of low-and intermediate-mass stars, while its influence on the evolution of massive stars (M > 10Msolar) is minimal. We find that employing the revised rate suppresses helium shell flashes on AGB phase for stars in the initial mass range 0.8<=M/Msolar<=6, which is contradictory to what is observed. The absence of helium shell flashes is due to the weak temperature dependence of the revised triple-α reaction cross section at the temperature involved. In our models, it is suggested that the temperature dependence of the cross section should have at least ν > 10 at T = 1-1.2×108K where the cross section is proportional to Tν. We also derive the helium ignition curve to estimate the maximum cross section to retain the low-mass first red giants. The semi-analytically derived ignition curves suggest that the reaction rate should be less than ~ 10-29 cm6 s-1 mole-2 at ~ 107.8 K, which corresponds to about three orders of magnitude larger than that of the NACRE compilation.
Alexander, Angel M; Flynn, Kathryn E; Hahn, Elizabeth A; Jeffery, Diana D; Keefe, Francis J; Reeve, Bryce B; Schultz, Wesley; Reese, Jennifer Barsky; Shelby, Rebecca A; Weinfurt, Kevin P
2014-08-01
There is a significant gap in research regarding the readability and comprehension of existing sexual function measures. Patient-reported outcome measures may use terms not well understood by respondents with low literacy. This study aims to test comprehension of words and phrases typically used in sexual function measures to improve validity for all individuals, including those with low literacy. We recruited 20 men and 28 women for cognitive interviews on version 2.0 of the Patient-Reported Outcome Measurement Information System(®) (PROMIS(®) ) Sexual Function and Satisfaction measures. We assessed participants' reading level using the word reading subtest of the Wide Range Achievement Test. Sixteen participants were classified as having low literacy. In the first round of cognitive interviews, each survey item was reviewed by five or more people, at least two of whom had lower than a ninth-grade reading level (low literacy). Patient feedback was incorporated into a revised version of the items. In the second round of interviews, an additional three or more people (at least one with low literacy) reviewed each revised item. Participants with low literacy had difficulty comprehending terms such as aroused, orgasm, erection, ejaculation, incontinence, and vaginal penetration. Women across a range of literacy levels had difficulty with clinical terms like labia and clitoris. We modified unclear terms to include parenthetical descriptors or slang equivalents, which generally improved comprehension. Common words and phrases used across measures of self-reported sexual function are not universally understood. Researchers should appreciate these misunderstandings as a potential source of error in studies using self-reported measures of sexual function. This study also provides evidence for the importance of including individuals with low literacy in cognitive pretesting during the measure development. © 2014 International Society for Sexual Medicine.
76 FR 51123 - Privacy Act of 1974, as Amended
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-17
... information such as income range, likelihood of being unbanked, and gender in determining what types of... demographic data, such as income range, gender or other characteristics.'' The paragraph is revised to read... as demographic data, such as income range, gender or other characteristics.'' * * * * * Dated: August...
Ji, Baochao; Xu, Enjie; Cao, Li; Yang, Desheng; Xu, Boyong; Guo, Wentao; Aili, Rehei
2015-02-01
To analyze the results of pathogenic bacteria culture on chronic periprosthetic joint infection after total knee arthroplasty (TKA) and total hip arthroplasty (THA). The medical data of 23 patients with chronic periprosthetic joint infection after TKA or THA from September 2010 to March 2014 were reviewed. Fifteen cases of TKA and 8 cases of THA were included in this study. There were 12 male and 11 female patients with the mean age of 62 years (range from 32 to 79 years), and among them 9 patients with sinus. All patients discontinued antibiotic therapy for a minimum of 2 weeks before arthrocentesis, taking pathogenic bacteria culture and antimicrobial susceptibility test by using synovial fluid taken preoperatively and intraoperatively of revision. Common pathogenic bacteria culture and pathological biopsy were taken on tissues intraoperatively of revision. Culture-negative specimens were prolonged the period of incubation for 2 weeks. The overall culture-positive rate of all 23 patients for 1 week before revision was 30.4% (7/23), and the positive rate of culture-negative samples which prolonged for 2 weeks was 39.1% (9/23). The overall culture-positive rate of patients for 1 week intraoperatively of revision was 60.9% (14/23), and the positive rate of culture-negative samples which prolonged for 2 weeks was 82.6% (19/23). The incubation results of 7 cases (30.4%) preoperatively conformed to that of intraoperation. The culture-positive rate of pathogenic bacteria culture can be increased evidently by discontinuing antimicrobial therapy for a minimum of 2 weeks prior to the definite diagnosis.
User manual for NASA Lewis 10 by 10 foot supersonic wind tunnel. Revised
NASA Technical Reports Server (NTRS)
Soeder, Ronald H.
1995-01-01
This manual describes the 10- by 10-Foot Supersonic Wind Tunnel at the NASA Lewis Research Center and provides information for users who wish to conduct experiments in this facility. Tunnel performance operating envelopes of altitude, dynamic pressure, Reynolds number, total pressure, and total temperature as a function of test section Mach number are presented. Operating envelopes are shown for both the aerodynamic (closed) cycle and the propulsion (open) cycle. The tunnel test section Mach number range is 2.0 to 3.5. General support systems, such as air systems, hydraulic system, hydrogen system, fuel system, and Schlieren system, are described. Instrumentation and data processing and acquisition systems are also described. Pretest meeting formats and schedules are outlined. Tunnel user responsibility and personnel safety are also discussed.
Math anxiety differentially affects WAIS-IV arithmetic performance in undergraduates.
Buelow, Melissa T; Frakey, Laura L
2013-06-01
Previous research has shown that math anxiety can influence the math performance level; however, to date, it is unknown whether math anxiety influences performance on working memory tasks during neuropsychological evaluation. In the present study, 172 undergraduate students completed measures of math achievement (the Math Computation subtest from the Wide Range Achievement Test-IV), math anxiety (the Math Anxiety Rating Scale-Revised), general test anxiety (from the Adult Manifest Anxiety Scale-College version), and the three Working Memory Index tasks from the Wechsler Adult Intelligence Scale-IV Edition (WAIS-IV; Digit Span [DS], Arithmetic, Letter-Number Sequencing [LNS]). Results indicated that math anxiety predicted performance on Arithmetic, but not DS or LNS, above and beyond the effects of gender, general test anxiety, and math performance level. Our findings suggest that math anxiety can negatively influence WAIS-IV working memory subtest scores. Implications for clinical practice include the utilization of LNS in individuals expressing high math anxiety.
Evaluation of the Edinburgh Post Natal Depression Scale using Rasch analysis
Pallant, Julie F; Miller, Renée L; Tennant, Alan
2006-01-01
Background The Edinburgh Postnatal Depression Scale (EPDS) is a 10 item self-rating post-natal depression scale which has seen widespread use in epidemiological and clinical studies. Concern has been raised over the validity of the EPDS as a single summed scale, with suggestions that it measures two separate aspects, one of depressive feelings, the other of anxiety. Methods As part of a larger cross-sectional study conducted in Melbourne, Australia, a community sample (324 women, ranging in age from 18 to 44 years: mean = 32 yrs, SD = 4.6), was obtained by inviting primiparous women to participate voluntarily in this study. Data from the EPDS were fitted to the Rasch measurement model and tested for appropriate category ordering, for item bias through Differential Item Functioning (DIF) analysis, and for unidimensionality through tests of the assumption of local independence. Results Rasch analysis of the data from the ten item scale initially demonstrated a lack of fit to the model with a significant Item-Trait Interaction total chi-square (chi Square = 82.8, df = 40; p < .001). Removal of two items (items 7 and 8) resulted in a non-significant Item-Trait Interaction total chi-square with a residual mean value for items of -0.467 with a standard deviation of 0.850, showing fit to the model. No DIF existed in the final 8-item scale (EPDS-8) and all items showed fit to model expectations. Principal Components Analysis of the residuals supported the local independence assumption, and unidimensionality of the revised EPDS-8 scale. Revised cut points were identified for EPDS-8 to maintain the case identification of the original scale. Conclusion The results of this study suggest that EPDS, in its original 10 item form, is not a viable scale for the unidimensional measurement of depression. Rasch analysis suggests that a revised eight item version (EPDS-8) would provide a more psychometrically robust scale. The revised cut points of 7/8 and 9/10 for the EPDS-8 show high levels of agreement with the original case identification for the EPDS-10. PMID:16768803
Baiden, F; Malm, K; Bart-Plange, C; Hodgson, A; Chandramohan, D; Webster, J; Owusu-Agyei, S
2014-06-01
The presumptive approach was the World Health Organisation (WHO) recommended to the management of malaria for many years and this was incorporated into syndromic guidelines such as the Integrated Management of Childhood Illnesses (IMCI). In early 2010 however, WHO issued revised treatment guidelines that call for a shift from the presumptive to the test-based approach. Practically, this implies that in all suspected cases, the diagnosis of uncomplicated malaria should be confirmed using rapid test before treatment is initiated. This revision effectively brings to an end an era of clinical practice that span several years. Its implementation has important implications for the health systems in malaria-endemic countries. On the basis of research in Ghana and other countries, and evidence from program work, the Ghana National Malaria Control Program has issued revised national treatment guidelines that call for implementation of test-based management of malaria in all cases, and across all age groups. This article reviews the evidence and the technical basis for the shift to test-based management and examines the implications for malaria control in Ghana.
REVISED TREATMENT OF N2 O5 HYDROLYSIS IN CMAQ
In this presentation, revised treatment of homogeneous and heterogeneous hydrolysis of dinitrogen pentoxide in the Community Multiscale Air Quality model version 4.6 are described. A series of model sensitivity tests are conducted and compared with observations of total atmosphe...
77 FR 72781 - Standards Improvement Project-Phase IV
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-06
... prepare and maintain written training-certification records for personal protective equipment, revised... revising the standards related to fit testing personal protective equipment, notably Sec. Sec. 1926.103 and... requirement to certify personal protective equipment (PPE) training. OSHA concluded that it could obtain the...
ERIC Educational Resources Information Center
Lyrakos, George N.; Damigos, Dimitrios; Mavreas, Venetsanos; Georgia, Kostopanagiotou; Dimoliatis, Ioannis D. K.
2010-01-01
The life orientation test-revised (LOT-R) (Scheier et al. in "Journal of Personality and Social Psychology" 67:1063-1078, 1994) is a brief measure for assessing dispositional optimism. The aim of this study was to develop a Greek language version of the LOT-R and to assess the instrument's psychometric properties. The LOT-R was…
An empirical test of Rogers' original and revised theory of correlates in adolescents.
Yarcheski, A; Mahon, N E
1991-12-01
The purpose of this study was to examine Rogers' original and revised theory of correlates in adolescents. The correlates were measured by Perceived Field Motion, Human Field Rhythms, Creativity, Sentience, Fast Tempo, and Waking Periods. The original theory was tested with data obtained from samples of early (n = 116), middle (n = 116), and late (n = 116) adolescents. The revised theory was tested in a fourth selectively combined sample of adolescents, aged 12 to 21 (n = 89). Data were collected in classroom settings. Although the findings did not support either theory, they did indicate that: (1) four of the six correlates studied performed as correlates when examined in three discrete phases of adolescence, as determined by chronological age, (2) the means of the individual correlates increased slightly in frequency levels developmentally, and (3) the correlates emerged at different frequency levels when examined in adolescents, aged 12 to 21.
Rank Determination of Mental Functions by 1D Wavelets and Partial Correlation.
Karaca, Y; Aslan, Z; Cattani, C; Galletta, D; Zhang, Y
2017-01-01
The main aim of this paper is to classify mental functions by the Wechsler Adult Intelligence Scale-Revised tests with a mixed method based on wavelets and partial correlation. The Wechsler Adult Intelligence Scale-Revised is a widely used test designed and applied for the classification of the adults cognitive skills in a comprehensive manner. In this paper, many different intellectual profiles have been taken into consideration to measure the relationship between the mental functioning and psychological disorder. We propose a method based on wavelets and correlation analysis for classifying mental functioning, by the analysis of some selected parameters measured by the Wechsler Adult Intelligence Scale-Revised tests. In particular, 1-D Continuous Wavelet Analysis, 1-D Wavelet Coefficient Method and Partial Correlation Method have been analyzed on some Wechsler Adult Intelligence Scale-Revised parameters such as School Education, Gender, Age, Performance Information Verbal and Full Scale Intelligence Quotient. In particular, we will show that gender variable has a negative but a significant role on age and Performance Information Verbal factors. The age parameters also has a significant relation in its role on Performance Information Verbal and Full Scale Intelligence Quotient change.
The natural history of perforated marginal ulcers after gastric bypass surgery.
Altieri, Maria S; Pryor, Aurora; Yang, Jie; Yin, Donglei; Docimo, Salvatore; Bates, Andrew; Talamini, Mark; Spaniolas, Konstantinos
2018-03-01
Although perforated marginal ulcers (pMU) following Roux-en-Y Gastric Bypass (RYGB) represent a surgical emergency, the epidemiology and outcome of this condition is not well understood. The purpose of this study was to evaluate incidence of pMU following RYGB and assess the natural history of this complication. The SPARCS administrative database was used to identify patients undergoing RYGB between 2005 and 2010. With the use of a unique identifier, we followed patients up to 2014 for subsequent admission and re-intervention (repair or revision) for perforated MU. Groups were compared using Chi square tests with exact p values based on Monte Carlo simulation, t test with unequal variances, and the Wilcoxon rank-sum test when appropriate. We identified 35,080 RYGB patients; 292 patients (0.83%) developed pMU 937 (443-1546) days following RYGB [Median (Q1-Q3)]. Among these 292 patients, tobacco use was present in one-third of patients. Repair of the perforation was performed in 115 patients, while anastomotic revision was reported in 64. Patients who underwent revision were more likely to have respiratory complications. Hospital length of stay was significantly longer for patients managed with RYGB revision (Median, Q1-Q3:7, 5-14, vs 6, 4-7, days, p = 0.001). Recurrence of marginal ulcer was common after either intervention (26.09% for repair and 29.69% for revision, p = 0.726). Following RYGB, the incidence of pMU is small. Anastomotic revision for pMU is associated with prolonged length of stay compared to repair alone. Importantly, recurrence after intervention of pMU is common, suggesting possible value of a routine surveillance program for patients following pMU.
Megas, Panagiotis; Georgiou, Christos S; Panagopoulos, Andreas; Kouzelis, Antonis
2014-12-31
The transfemoral and the extended trochanteric osteotomies are the most common osteotomies used in femoral revision, both when proximal or diaphyseal fixation of the new component has been decided. We present an alternative approach to the trochanteric osteotomies, most frequently used with distally fixated stems, to overcome their shortcomings of osteotomy migration and nonunion, but, most of all, the uncontrollable fragmentation of the femur. The procedure includes a complete circular femoral osteotomy just below the stem tip to prevent distal fracture propagation and a subsequent preplanned segmentation of the proximal femur for better exposure and fast removal of the old prosthesis. The bone fragments are reattached with cerclage wires to the revision prosthesis, which is safely anchored distally. A modified posterolateral approach is used, as the preservation of the continuity of the abductors, the greater trochanter, and the vastus lateralis is a prerequisite. Between 2006 and 2012, 47 stems (33 women, 14 men, mean age 68 years, range 39-88 years) were revised using this technique. They were 12 (26%) stable and 35 (74%) loose prostheses and were all revised to tapered, fluted, grit-blasted stems. No fracture of the trochanters or the distal femur occurred intraoperatively. Mean follow-up was 28 months (range 6-70 months). No case of trochanteric migration or nonunion of the osteotomies was recorded. Restoration of the preexisting bone defects occurred in 83% of the patients. Three patients required repeat revision due to dislocation and one due to a postoperative periprosthetic fracture. None of the failures was attributed to the procedure itself. This new osteotomy technique may seem aggressive at first, but, at least in our hands, has effectively increased the speed of the femoral revision, particularly for the most difficult well-fixed components, but not at the expense of safety.
NASA Astrophysics Data System (ADS)
Szilagyi, Jozsef; Crago, Richard; Qualls, Russell J.
2016-09-01
The original and revised versions of the generalized complementary relationship (GCR) of evaporation (ET) were tested with six-digit Hydrologic Unit Code (HUC6) level long-term (1981-2010) water-balance data (sample size of 334). The two versions of the GCR were calibrated with Parameter-Elevation Regressions on Independent Slopes Model (PRISM) mean annual precipitation (P) data and validated against water-balance ET (ETwb) as the difference of mean annual HUC6-averaged P and United States Geological Survey HUC6 runoff (Q) rates. The original GCR overestimates P in about 18% of the PRISM grid points covering the contiguous United States in contrast with 12% of the revised version. With HUC6-averaged data the original version has a bias of -25 mm yr-1 vs the revised version's -17 mm yr-1, and it tends to more significantly underestimate ETwb at high values than the revised one (slope of the best fit line is 0.78 vs 0.91). At the same time it slightly outperforms the revised version in terms of the linear correlation coefficient (0.94 vs 0.93) and the root-mean-square error (90 vs 92 mm yr-1).
Redefining the age of Clovis: implications for the peopling of the Americas.
Waters, Michael R; Stafford, Thomas W
2007-02-23
The Clovis complex is considered to be the oldest unequivocal evidence of humans in the Americas, dating between 11,500 and 10,900 radiocarbon years before the present (14C yr B.P.). Adjusted 14C dates and a reevaluation of the existing Clovis date record revise the Clovis time range to 11,050 to 10,800 14C yr B.P. In as few as 200 calendar years, Clovis technology originated and spread throughout North America. The revised age range for Clovis overlaps non-Clovis sites in North and South America. This and other evidence imply that humans already lived in the Americas before Clovis.
Test, revision, and cross-validation of the Physical Activity Self-Definition Model.
Kendzierski, Deborah; Morganstein, Mara S
2009-08-01
Structural equation modeling was used to test an extended version of the Kendzierski, Furr, and Schiavoni (1998) Physical Activity Self-Definition Model. A revised model using data from 622 runners fit the data well. Cross-validation indices supported the revised model, and this model also provided a good fit to data from 397 cyclists. Partial invariance was found across activities. In both samples, perceived commitment and perceived ability had direct effects on self-definition, and perceived wanting, perceived trying, and enjoyment had indirect effects. The contribution of perceived ability to self-definition did not differ across activities. Implications concerning the original model, indirect effects, skill salience, and the role of context in self-definition are discussed.
Smoking is associated with earlier time to revision of total knee arthroplasty.
Lim, Chin Tat; Goodman, Stuart B; Huddleston, James I; Harris, Alex H S; Bhowmick, Subhrojyoti; Maloney, William J; Amanatullah, Derek F
2017-10-01
Smoking is associated with early postoperative complications, increased length of hospital stay, and an increased risk of revision after total knee arthroplasty (TKA). However, the effect of smoking on time to revision TKA is unknown. A total of 619 primary TKAs referred to an academic tertiary center for revision TKA were retrospectively stratified according to the patient smoking status. Smoking status was then analyzed for associations with time to revision TKA using a Chi square test. The association was also analyzed according to the indication for revision TKA. Smokers (37/41, 90%) have an increased risk of earlier revision for any reason compared to non-smokers (274/357, 77%, p=0.031). Smokers (37/41, 90%) have an increased risk of earlier revision for any reason compared to ex-smokers (168/221, 76%, p=0.028). Subgroup analysis did not reveal a difference in indication for revision TKA (p>0.05). Smokers are at increased risk of earlier revision TKA when compared to non-smokers and ex-smokers. The risk for ex-smokers was similar to that of non-smokers. Smoking appears to have an all-or-none effect on earlier revision TKA as patients who smoked more did not have higher risk of early revision TKA. These results highlight the need for clinicians to urge patients not to begin smoking and encourage smokers to quit smoking prior to primary TKA. Copyright © 2017 Elsevier B.V. All rights reserved.
Gottschlich, Carsten; Schuhmacher, Dominic
2014-01-01
Finding solutions to the classical transportation problem is of great importance, since this optimization problem arises in many engineering and computer science applications. Especially the Earth Mover's Distance is used in a plethora of applications ranging from content-based image retrieval, shape matching, fingerprint recognition, object tracking and phishing web page detection to computing color differences in linguistics and biology. Our starting point is the well-known revised simplex algorithm, which iteratively improves a feasible solution to optimality. The Shortlist Method that we propose substantially reduces the number of candidates inspected for improving the solution, while at the same time balancing the number of pivots required. Tests on simulated benchmarks demonstrate a considerable reduction in computation time for the new method as compared to the usual revised simplex algorithm implemented with state-of-the-art initialization and pivot strategies. As a consequence, the Shortlist Method facilitates the computation of large scale transportation problems in viable time. In addition we describe a novel method for finding an initial feasible solution which we coin Modified Russell's Method.
González-Ibáñez, A; Mora, M; Gutiérrez-Maldonado, J; Ariza, A; Lourido-Ferreira, M R
2005-02-01
The aim of this study was to ascertain the possible differences in personality, psychopathology, and response to treatment in pathological gambling according to age. The sample, comprising 67 participants, was divided into three groups: 32.6% with ages ranging between 17 and 26 years, 31.3% between 27 and 43 years, and 35.8% over 44 years of age. The participants were administered the following tests, Minnesota Multiphasic Personality Inventory [MMPI; Hathaway, S.R. & McKinley, J.C. (1943, 1961). Cuestionario de personalidad MMPI. Madrid Seccion de Estudios de TEA ed. 1970, 1975], sensation-seeking questionnaire [SSS; Zuckerman, M. (1979). Sensation seeking; beyond the optimal level of arousal. Hillsdale, NJ: Lawrence Erlbaum Associates], and the Symptom Check List Revised [SCL-90-R; Derogatis, L.R. (1977). Symptom check list-90 revised. Administration scoring and procedures manual. Baltimore]. All underwent a group treatment programme that was carried out in the Pathological Gambling Unit at Ciutat Sanitaria i Universitaria de Bellvitge (CSUB), Teaching hospital, Barcelona, Spain. The findings show differences depending on age in the participants' personality and in psychopathology and in their response to treatment.
Gottschlich, Carsten; Schuhmacher, Dominic
2014-01-01
Finding solutions to the classical transportation problem is of great importance, since this optimization problem arises in many engineering and computer science applications. Especially the Earth Mover's Distance is used in a plethora of applications ranging from content-based image retrieval, shape matching, fingerprint recognition, object tracking and phishing web page detection to computing color differences in linguistics and biology. Our starting point is the well-known revised simplex algorithm, which iteratively improves a feasible solution to optimality. The Shortlist Method that we propose substantially reduces the number of candidates inspected for improving the solution, while at the same time balancing the number of pivots required. Tests on simulated benchmarks demonstrate a considerable reduction in computation time for the new method as compared to the usual revised simplex algorithm implemented with state-of-the-art initialization and pivot strategies. As a consequence, the Shortlist Method facilitates the computation of large scale transportation problems in viable time. In addition we describe a novel method for finding an initial feasible solution which we coin Modified Russell's Method. PMID:25310106
Ogrinc, Greg; Davies, Louise; Goodman, Daisy; Batalden, Paul; Davidoff, Frank; Stevens, David
2015-01-01
Since the publication of Standards for Quality Improvement Reporting Excellence (SQUIRE 1.0) guidelines in 2008, the science of the field has advanced considerably. In this manuscript we describe the development of SQUIRE 2.0 and its key components. We undertook the revision between 2012 and 2015, using 1) semistructured interviews and focus groups to evaluate SQUIRE 1.0 plus feedback from an international steering group; 2) two face-to-face consensus meetings to develop interim drafts; and 3) pilot testing with authors and a public comment period. SQUIRE 2.0 emphasizes the reporting of three key components of systematic efforts to improve the quality, value, and safety of health care: the use of formal and informal theory in planning, implementing, and evaluating improvement work; the context in which the work is done; and the study of the intervention(s). SQUIRE 2.0 is intended for reporting the range of methods used to improve health care, recognizing that they can be complex and multidimensional. It provides common ground to share these discoveries in the scholarly literature (www.squire-statement.org). PMID:26517437
Ogrinc, Greg; Davies, Louise; Goodman, Daisy; Batalden, Paul; Davidoff, Frank; Stevens, David
2015-01-01
In the past several years, the science of health care improvement has advanced considerably. In this article, we describe the development of SQUIRE 2.0 and its key components. We undertook the revision between 2012 and 2015 using (1) interviews and focus groups to evaluate SQUIRE 1.0 plus feedback from an international steering group, (2) face-to-face consensus meetings to develop interim drafts, and (3) pilot testing with authors and a public comment period. SQUIRE 2.0 emphasizes 3 key components of systematic efforts to improve the quality, value, and safety of health care: formal and informal theory in planning, implementing, and evaluating improvement work; the context in which the work is done; and the study of the intervention(s). SQUIRE 2.0 is intended for reporting the range of methods used to improve health care, recognizing that they can be complex and multidimensional. It provides common ground to share these discoveries in the scholarly literature (www.squire-statement.org). © The Author(s) 2015.
Ogrinc, Greg; Davies, Louise; Goodman, Daisy; Batalden, Paul; Davidoff, Frank; Stevens, David
2015-01-01
Since the publication of Standards for Quality Improvement Reporting Excellence (SQUIRE 1.0) guidelines in 2008, the science of the field has advanced considerably. In this manuscript we describe the development of SQUIRE 2.0 and its key components. We undertook the revision between 2012 and 2015, using 1) semistructured interviews and focus groups to evaluate SQUIRE 1.0 plus feedback from an international steering group; 2) two face-to-face consensus meetings to develop interim drafts; and 3) pilot testing with authors and a public comment period. SQUIRE 2.0 emphasizes the reporting of three key components of systematic efforts to improve the quality, value, and safety of health care: the use of formal and informal theory in planning, implementing, and evaluating improvement work; the context in which the work is done; and the study of the intervention(s). SQUIRE 2.0 is intended for reporting the range of methods used to improve health care, recognizing that they can be complex and multidimensional. It provides common ground to share these discoveries in the scholarly literature (www.squire-statement.org).
Validation of a clinical critical thinking skills test in nursing.
Shin, Sujin; Jung, Dukyoo; Kim, Sungeun
2015-01-27
The purpose of this study was to develop a revised version of the clinical critical thinking skills test (CCTS) and to subsequently validate its performance. This study is a secondary analysis of the CCTS. Data were obtained from a convenience sample of 284 college students in June 2011. Thirty items were analyzed using item response theory and test reliability was assessed. Test-retest reliability was measured using the results of 20 nursing college and graduate school students in July 2013. The content validity of the revised items was analyzed by calculating the degree of agreement between instrument developer intention in item development and the judgments of six experts. To analyze response process validity, qualitative data related to the response processes of nine nursing college students obtained through cognitive interviews were analyzed. Out of initial 30 items, 11 items were excluded after the analysis of difficulty and discrimination parameter. When the 19 items of the revised version of the CCTS were analyzed, levels of item difficulty were found to be relatively low and levels of discrimination were found to be appropriate or high. The degree of agreement between item developer intention and expert judgments equaled or exceeded 50%. From above results, evidence of the response process validity was demonstrated, indicating that subjects respondeds as intended by the test developer. The revised 19-item CCTS was found to have sufficient reliability and validity and will therefore represents a more convenient measurement of critical thinking ability.
Validation of a clinical critical thinking skills test in nursing
2015-01-01
Purpose: The purpose of this study was to develop a revised version of the clinical critical thinking skills test (CCTS) and to subsequently validate its performance. Methods: This study is a secondary analysis of the CCTS. Data were obtained from a convenience sample of 284 college students in June 2011. Thirty items were analyzed using item response theory and test reliability was assessed. Test-retest reliability was measured using the results of 20 nursing college and graduate school students in July 2013. The content validity of the revised items was analyzed by calculating the degree of agreement between instrument developer intention in item development and the judgments of six experts. To analyze response process validity, qualitative data related to the response processes of nine nursing college students obtained through cognitive interviews were analyzed. Results: Out of initial 30 items, 11 items were excluded after the analysis of difficulty and discrimination parameter. When the 19 items of the revised version of the CCTS were analyzed, levels of item difficulty were found to be relatively low and levels of discrimination were found to be appropriate or high. The degree of agreement between item developer intention and expert judgments equaled or exceeded 50%. Conclusion: From above results, evidence of the response process validity was demonstrated, indicating that subjects respondeds as intended by the test developer. The revised 19-item CCTS was found to have sufficient reliability and validity and will therefore represents a more convenient measurement of critical thinking ability. PMID:25622716
Revised Reynolds Stress and Triple Product Models
NASA Technical Reports Server (NTRS)
Olsen, Michael E.; Lillard, Randolph P.
2017-01-01
Revised versions of Lag methodology Reynolds-stress and triple product models are applied to accepted test cases to assess the improvement, or lack thereof, in the prediction capability of the models. The Bachalo-Johnson bump flow is shown as an example for this abstract submission.
FIELD TEST OF THE PROPOSED REVISED HAZARD RANKING SYSTEM (HRS)
The Superfund Amendments and Reauthorization Act of 1986 (SARA) requires the U.S. Environmental Protection Agency (EPA) to revise the Hazard Ranking System (HRS) so that, to the maximum extent feasible, it accurately assesses the relative risks associated with actual or potent...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-07
... Promulgation of Air Quality Implementation Plans; Massachusetts; Revisions to Fossil Fuel Utilization and..., inspection, maintenance and testing requirements for certain fossil fuel utilization facilities, rename and... fossil fuel utilization facility regulation, source registration regulation, and new industrial...
PROPOSED REVISION OF MIL-H-81019, HYDRAULIC FLUID, PETROLEUM BASE, ULTRA-LOW TEMPERATURE,
81019 in line with that of the fluid currently being supplied under MIL -H-5606B. (Author)...An investigation was conducted to revise specification requirements and test methods which would bring the quality of the fluid supplied under MIL -H
Physical Test Prototypes Based on Microcontroller
NASA Astrophysics Data System (ADS)
Paramitha, S. T.
2017-03-01
The purpose of this study was to produce a prototype of a physical test-based microcontroller. The research method uses the research and development of the Borg and gall. The procedure starts from the study; research and information collecting, planning, develop preliminary form of product, preliminary field testing, main product revision, playing field testing, operational product revision, field operational testing, final product revision, dissemination and implementation. Validation of the product, obtained through expert evaluation; test products of small scale and large scale; effectiveness test; evaluation of respondents. The results showed that the eligibility assessment of prototype products based physical tests microcontroller. Based on the ratings of seven experts showed that 87% included in the category of “very good” and 13% included in the category of “good”. While the effectiveness of the test results showed that 1). The results of the experimental group to test sit-ups increase by 40% and the control group by 15%. 2). The results of the experimental group to test push-ups increased by 30% and the control group by 10%. 3). The results of the experimental group to test the Back-ups increased by 25% and the control group by 10%. With a significant value of 0.002 less than 0.05, product means a physical test prototype microcontroller based, proven effective in improving the results of physical tests. Conclusions and recommendations; Product physical microcontroller-based assays, can be used to measure the physical tests of pushups, sit ups, and back-ups.
Testing an Earthquake Prediction Algorithm: The 2016 New Zealand and Chile Earthquakes
NASA Astrophysics Data System (ADS)
Kossobokov, Vladimir G.
2017-05-01
The 13 November 2016, M7.8, 54 km NNE of Amberley, New Zealand and the 25 December 2016, M7.6, 42 km SW of Puerto Quellon, Chile earthquakes happened outside the area of the on-going real-time global testing of the intermediate-term middle-range earthquake prediction algorithm M8, accepted in 1992 for the M7.5+ range. Naturally, over the past two decades, the level of registration of earthquakes worldwide has grown significantly and by now is sufficient for diagnosis of times of increased probability (TIPs) by the M8 algorithm on the entire territory of New Zealand and Southern Chile as far as below 40°S. The mid-2016 update of the M8 predictions determines TIPs in the additional circles of investigation (CIs) where the two earthquakes have happened. Thus, after 50 semiannual updates in the real-time prediction mode, we (1) confirm statistically approved high confidence of the M8-MSc predictions and (2) conclude a possibility of expanding the territory of the Global Test of the algorithms M8 and MSc in an apparently necessary revision of the 1992 settings.
Short-Term Metal Ion Trends Following Removal of Recalled Modular Neck Femoral Stems.
Barlow, Brian T; Assini, Joseph; Boles, John; Lee, Yuo-Yu; Westrich, Geoffrey H
2015-07-01
Elevated serum metal ions have been well documented with the Rejuvenate modular neck femoral stem (Stryker, Mahwah, NJ); however, the rate at which ion levels decline following revision is less clear. This study included fifty-nine consecutive revisions of Rejuvenate stems for symptomatic ALTR. Blood tests prior to revision and postoperatively at 6weeks, 3months, 6months, and 1year measured serum cobalt and chromium concentrations, ESR, and CRP. At six weeks following revision of a unilateral Rejuvenate, cobalt and chromium levels dropped from preoperative levels by 67% and 42%, respectively. At three months, cobalt levels declined to 19% of preoperative values, but chromium levels remained stable. With this information, surgeons can set realistic expectations for serum metal ion levels following Rejuvenate stem revision. Published by Elsevier Inc.
Results of revision total knee arthroplasty using press-fit cementless stem.
Iamaguchi, Maurício Masasi; de Castro, Fernando Bley Vicente; Gobbi, Riccardo Gomes; Tirico, Luis Eduardo Passarelli; Pécora, José Ricardo; Camanho, Gilberto Luis
2013-01-01
To show our experience with press-fit cementless stem and metaphyseal fixation with cement in a selected series of patients who underwent revision total knee arthroplasty. Thirty-four patients (35 knees) underwent revision total knee arthroplasty using the press-fit technique. Minimum follow-up was one year (mean 2.2 years) with a maximum length of three years. Of 34 patients, 20 were women and 14 were men. There was one death due to causes not related to arthroplasty and one patient dropout. There were no cases in which further review was necessary. Patients who underwent revision had clinical and functional improvement demonstrated by the results of the KSS, results of the SF-36 quality of life questionnaire, through gains in range of motion and improved limb alignment. There was postoperative clinical and functional improvement in comparison to the preoperative status in revision total knee arthroplasty with press-fit cementless stem. Level of Evidence IV, Case series.
Enhancing Medical Student Education by Implementing a Competency-Based Ophthalmology Curriculum.
Succar, Tony; McCluskey, Peter; Grigg, John
2017-01-01
To evaluate innovative educational strategies that help optimize ophthalmology teaching in a crowded medical curriculum. The knowledge acquisition and perceptions of medical students undertaking the revised competency-based curriculum were compared with the prior content-based curriculum within the Sydney Medical Program. A mixed-methods research design was employed to include both quantitative and qualitative dimensions in evaluating the revised curriculum with medical students (n = 328) undergoing their ophthalmology rotation. Quantitative evaluation was performed with a 20-item multiple choice pre- and post-test of ophthalmic knowledge. A 12-month follow-up test was readministered to compare the long-term retention rate of graduates. Qualitative evaluation was measured with student satisfaction questionnaires. In the original curriculum there was an improvement of 19.9% from pre- to post-test scores [2.15; 95% confidence interval (CI), 1.35-2.94; P < 0.001] and a greater improvement of 31.6% from pre- to post-test (3.50; 95% CI, 3.03-3.97; P < 0.001) in the revised curriculum. When assessing retained knowledge at 12 months, students from the revised curriculum scored 11.5% higher than students from the original curriculum (1.56; 95% CI, 0.42-2.71; P = 0.008). In addition, qualitative feedback also improved, with the rotation being highly valued. The revised ophthalmic curriculum resulted in an increase in academic performance and a higher degree of student satisfaction. Given the gradual decline of ophthalmic education in the standard medical school curriculum, our results are timely in providing guidance for minimum ophthalmic curriculum exposure and strategies to improve ophthalmic education in medical schools. Copyright© 2017 Asia-Pacific Academy of Ophthalmology.
Tilley, Barbara C.; LaPelle, Nancy R.; Goetz, Christopher G.; Stebbins, Glenn T.
2016-01-01
Background Cognitive pretesting, a qualitative step in scale development, precedes field testing and assesses the difficulty of instrument completion for examiners and respondents. Cognitive pretesting assesses respondent interest, attention span, discomfort, and comprehension, and highlights problems with the logical structure of questions/response options that can affect understanding. In the past this approach was not consistently used in the development or revision of movement disorders scales. Methods We applied qualitative cognitive pretesting using testing guides in development of the Movement Disorder Society-sponsored revision of the Unified Parkinson’s Disease Rating Scale (MDS-UPDRS). The guides were based on qualitative techniques, verbal probing and “think-aloud” interviewing, to identify problems with the scale from the patient and rater perspectives. English-speaking Parkinson’s disease patients and movement disorders specialists (raters) from multiple specialty clinics in the United States, Western Europe and Canada used the MDS-UPDRS and completed the testing guides. Results Two rounds of cognitive pretesting were necessary before proceeding to field testing of the revised scale to assess clinimetric properties. Scale revisions based on cognitive pretesting included changes in phrasing, simplification of some questions, and addition of a reassuring statement explaining that not all PD patients experience the symptoms described in the questions. Conclusions The strategy of incorporating cognitive pretesting into scale development and revision provides a model for other movement disorders scales. Cognitive pretesting is being used in translating the MDS-UPDRS into multiple languages to improve comprehension and acceptance and in the development of a new Unified Dyskinesia Rating Scale for Parkinson’s disease patients. PMID:24613868
Jameson, S S; Baker, P N; Mason, J; Rymaszewska, M; Gregg, P J; Deehan, D J; Reed, M R
2013-06-01
The popularity of cementless total hip replacement (THR) has surpassed cemented THR in England and Wales. This retrospective cohort study records survival time to revision following primary cementless THR with the most common combination (accounting for almost a third of all cementless THRs), and explores risk factors independently associated with failure, using data from the National Joint Registry for England and Wales. Patients with osteoarthritis who had a DePuy Corail/Pinnacle THR implanted between the establishment of the registry in 2003 and 31 December 2010 were included within analyses. There were 35 386 procedures. Cox proportional hazard models were used to analyse the extent to which the risk of revision was related to patient, surgeon and implant covariates. The overall rate of revision at five years was 2.4% (99% confidence interval 2.02 to 2.79). In the final adjusted model, we found that the risk of revision was significantly higher in patients receiving metal-on-metal (MoM: hazard ratio (HR) 1.93, p < 0.001) and ceramic-on-ceramic bearings (CoC: HR 1.55, p = 0.003) compared with the best performing bearing (metal-on-polyethylene). The risk of revision was also greater for smaller femoral stems (sizes 8 to 10: HR 1.82, p < 0.001) compared with mid-range sizes. In a secondary analysis of only patients where body mass index (BMI) data were available (n = 17 166), BMI ≥ 30 kg/m(2) significantly increased the risk of revision (HR 1.55, p = 0.002). The influence of the bearing on the risk of revision remained significant (MoM: HR 2.19, p < 0.001; CoC: HR 2.09, p = 0.001). The risk of revision was independent of age, gender, head size and offset, shell, liner and stem type, and surgeon characteristics. We found significant differences in failure between bearing surfaces and femoral stem size after adjustment for a range of covariates in a large cohort of single-brand cementless THRs. In this study of procedures performed since 2003, hard bearings had significantly higher rates of revision, but we found no evidence that head size had an effect. Patient characteristics, such as BMI and American Society of Anesthesiologists grade, also influence the survival of cementless components.
ERIC Educational Resources Information Center
Breyer, F. Jay; Attali, Yigal; Williamson, David M.; Ridolfi-McCulla, Laura; Ramineni, Chaitanya; Duchnowski, Matthew; Harris, April
2014-01-01
In this research, we investigated the feasibility of implementing the "e-rater"® scoring engine as a check score in place of all-human scoring for the "Graduate Record Examinations"® ("GRE"®) revised General Test (rGRE) Analytical Writing measure. This report provides the scientific basis for the use of e-rater as a…
ERIC Educational Resources Information Center
Young, John W.; Klieger, David; Bochenek, Jennifer; Li, Chen; Cline, Fred
2014-01-01
Scores from the "GRE"® revised General Test provide important information regarding the verbal and quantitative reasoning abilities and analytical writing skills of applicants to graduate programs. The validity and utility of these scores depend upon the degree to which the scores predict success in graduate and business school in…
Hypochondriasis: considerations for ICD-11.
van den Heuvel, Odile A; Veale, David; Stein, Dan J
2014-01-01
The World Health Organization (WHO) is currently revisiting the ICD. In the 10th version of the ICD, approved in 1990, hypochondriacal symptoms are described in the context of both the primary condition hypochondriacal disorder and as secondary symptoms within a range of other mental disorders. Expansion of the research base since 1990 makes a critical evaluation and revision of both the definition and classification of hypochondriacal disorder timely. This article addresses the considerations reviewed by members of the WHO ICD-11 Working Group on the Classification of Obsessive-Compulsive and Related Disorders in their proposal for the description and classification of hypochondriasis. The proposed revision emphasizes the phenomenological overlap with both anxiety disorders (e.g., fear, hypervigilance to bodily symptoms, and avoidance) and obsessive-compulsive and related disorders (e.g., preoccupation and repetitive behaviors) and the distinction from the somatoform disorders (presence of somatic symptom is not a critical characteristic). This revision aims to improve clinical utility by enabling better recognition and treatment of patients with hypochondriasis within the broad range of global health care settings.
Stein, Dan J; Phillips, Katharine A
2013-05-17
The revision of the Diagnostic and Statistical Manual of Mental Disorders (DSM) provides a useful opportunity to revisit debates about the nature of psychiatric classification. An important debate concerns the involvement of mental health consumers in revisions of the classification. One perspective argues that psychiatric classification is a scientific process undertaken by scientific experts and that including consumers in the revision process is merely pandering to political correctness. A contrasting perspective is that psychiatric classification is a process driven by a range of different values and that the involvement of patients and patient advocates would enhance this process. Here we draw on our experiences with input from the public during the deliberations of the Obsessive Compulsive-Spectrum Disorders subworkgroup of DSM-5, to help make the argument that psychiatric classification does require reasoned debate on a range of different facts and values, and that it is appropriate for scientist experts to review their nosological recommendations in the light of rigorous consideration of patient experience and feedback.
Evidence-Based School Behavior Assessment of Externalizing Behavior in Young Children.
Bagner, Daniel M; Boggs, Stephen R; Eyberg, Sheila M
2010-02-01
This study examined the psychometric properties of the Revised Edition of the School Observation Coding System (REDSOCS). Participants were 68 children ages 3 to 6 who completed parent-child interaction therapy for Oppositional Defiant Disorder as part of a larger efficacy trial. Interobserver reliability on REDSOCS categories was moderate to high, with percent agreement ranging from 47% to 90% (M = 67%) and Cohen's kappa coefficients ranging from .69 to .95 (M = .82). Convergent validity of the REDSOCS categories was supported by significant correlations with the Intensity Scale of the Sutter-Eyberg Student Behavior Inventory-Revised and related subscales of the Conners' Teacher Rating Scale-Revised: Long Version (CTRS-R: L). Divergent validity was indicated by nonsignificant correlations between REDSOCS categories and scales on the CTRS-R: L expected not to relate to disruptive classroom behavior. Treatment sensitivity was demonstrated for two of the three primary REDSOCS categories by significant pre to posttreatment changes. This study provides psychometric support for the designation of REDSOCS as an evidence-based assessment procedure for young children.
Standard tests for toughened resin composites, revised edition
NASA Technical Reports Server (NTRS)
1983-01-01
Several toughened resin systems are evaluated to achieve commonality for certain kinds of tests used to characterize toughened resin composites. Specifications for five tests were standardized; these test standards are described.
Reames, Davis L; Kasliwal, Manish K; Smith, Justin S; Hamilton, D Kojo; Arlet, Vincent; Shaffrey, Christopher I
2015-03-01
A retrospective review. To study time to development, clinical and radiographic characteristics, and management of proximal junctional kyphosis (PJK) following thoracolumbar instrumented fusion for adult spinal deformity (ASD). PJK continues to be a common mode of failure following ASD surgery. Although literature exists on possible risk factors, data on management remain limited. A retrospective review of medical records of 289 consecutive ASD patients who underwent posterior segmental instrumentation incorporating at least 5 segments was conducted. PJK was defined as proximal kyphotic angle >10 degrees. PJK occurred in 32 patients (11%) at a mean follow-up of 34 months (range, 1.3-61.9±19 mo). Sixteen (50%) patients were revised (mean, 1.7 revisions; range, 1-3) at a mean follow-up of 9.6 months (range, 0.7-40 mo); primary indications for revision were pain (n=16), myelopathy (n=6), instability (n=4), and instrumentation protrusion (n=2). Comparison of preindex and postindex surgery radiographic parameters demonstrated significant improvement in mean lumbar lordosis (24 vs. 42 degrees, P<0.001), pelvic incidence-lumbar lordosis mismatch (30 vs. 11 degrees, P<0.001), and pelvic tilt (29 vs. 23 degrees, P<0.011). The mean T5-T12 kyphosis worsened (30 vs. 53 degrees, P<0.001) and the mean global sagittal spinal alignment failed to improve (9.6 vs. 8.0 cm, P=0.76). There was no apparent relationship between the absolute PJK angle and revision surgery (P>0.05). The patients in this series who developed PJK had substantial preoperative positive sagittal malalignment that remained inadequately corrected following surgery, likely resulting from a combination of inadequate surgical correction and a significant compensatory increase in thoracic kyphosis. In the absence of direct relationship between a greater PJK angle and worse clinical outcome, clinical symptoms and neurological status rather than absolute reliance on radiographic parameters should drive the decision to pursue revision surgery.
Improvement of structural models using covariance analysis and nonlinear generalized least squares
NASA Technical Reports Server (NTRS)
Glaser, R. J.; Kuo, C. P.; Wada, B. K.
1992-01-01
The next generation of large, flexible space structures will be too light to support their own weight, requiring a system of structural supports for ground testing. The authors have proposed multiple boundary-condition testing (MBCT), using more than one support condition to reduce uncertainties associated with the supports. MBCT would revise the mass and stiffness matrix, analytically qualifying the structure for operation in space. The same procedure is applicable to other common test conditions, such as empty/loaded tanks and subsystem/system level tests. This paper examines three techniques for constructing the covariance matrix required by nonlinear generalized least squares (NGLS) to update structural models based on modal test data. The methods range from a complicated approach used to generate the simulation data (i.e., the correct answer) to a diagonal matrix based on only two constants. The results show that NGLS is very insensitive to assumptions about the covariance matrix, suggesting that a workable NGLS procedure is possible. The examples also indicate that the multiple boundary condition procedure more accurately reduces errors than individual boundary condition tests alone.
Are Shunt Revisions Associated with IQ in Congenital Hydrocephalus? A Meta -Analysis.
Arrington, C Nikki; Ware, Ashley L; Ahmed, Yusra; Kulesz, Paulina A; Dennis, Maureen; Fletcher, Jack M
2016-12-01
Although it is generally acknowledged that shunt revisions are associated with reductions in cognitive functions in individuals with congenital hydrocephalus, the literature yields mixed results and is inconclusive. The current study used meta-analytic methods to empirically synthesize studies addressing the association of shunt revisions and IQ in individuals with congenital hydrocephalus. Six studies and three in-house datasets yielded 11 independent samples for meta-analysis. Groups representing lower and higher numbers of shunt revisions were coded to generate effect sizes for differences in IQ scores. Mean effect size across studies was statistically significant, but small (Hedges' g = 0.25, p < 0.001, 95 % CI [0.08, 0.43]) with more shunt revisions associated with lower IQ scores. Results show an association of lower IQ and more shunt revisions of about 3 IQ points, a small effect, but within the error of measurement associated with IQ tests. Although clinical significance of this effect is not clear, results suggest that repeated shunt revisions because of shunt failure is associated with a reduction in cognitive functions.
Butler, Andrew J.; Cazeaux, Jennifer; Fidler, Anna; Jansen, Jessica; Lefkove, Nehama; Gregg, Melanie; Hall, Craig; Easley, Kirk A.; Shenvi, Neeta; Wolf, Steven L.
2012-01-01
Mental imagery can improve motor performance in stroke populations when combined with physical therapy. Valid and reliable instruments to evaluate the imagery ability of stroke survivors are needed to maximize the benefits of mental imagery therapy. The purposes of this study were to: examine and compare the test-retest intra-rate reliability of the Movement Imagery Questionnaire-Revised, Second Edition (MIQ-RS) in stroke survivors and able-bodied controls, examine internal consistency of the visual and kinesthetic items of the MIQ-RS, determine if the MIQ-RS includes both the visual and kinesthetic dimensions of mental imagery, correlate impairment and motor imagery scores, and investigate the criterion validity of the MIQ-RS in stroke survivors by comparing the results to the KVIQ-10. Test-retest analysis indicated good levels of reliability (ICC range: .83–.99) and internal consistency (Cronbach α: .95–.98) of the visual and kinesthetic subscales in both groups. The two-factor structure of the MIQ-RS was supported by factor analysis, with the visual and kinesthetic components accounting for 88.6% and 83.4% of the total variance in the able-bodied and stroke groups, respectively. The MIQ-RS is a valid and reliable instrument in the stroke population examined and able-bodied populations and therefore useful as an outcome measure for motor imagery ability. PMID:22474504
Fibrin tissue adhesive for face- and necklift.
Berry, M G; Stanek, Jan J
2015-10-01
Although available for decades, fibrin-based tissue adhesives (FTAs) have enjoyed only variable popularity in aesthetic surgery since their introduction in the 1980s. Whilst benefits in facelift surgery have been reported for a range of measures, including expanding haematoma, oedema and ecchymosis, irrefutable evidence has not yet been forthcoming. We instigated a prospective study to test the hypothesis that an underappreciated property of FTA, namely its ability to distribute tension, would reduce complications and revision due to early relapse. The study group comprised 100 consecutive facelifts with FTA. The comparative group comprised the immediate preceding 100 patients who underwent similar interventions, but with drains instead of FTA. All surgery was undertaken by the senior author using standard techniques and statistical analysis employing Fisher's exact test. The groups were comparable in age, gender distribution, co-morbidity and declared cigarette smoking. Complications were recorded in 24 patients with significantly more in the comparative group (p = 0.048), particularly hypertrophic scarring (p = 0.029). Although there appeared a greater prevalence of revision and cutaneous necrosis in the comparative group, these did not reach statistical significance. To the many published benefits, we can add that FTA can reduce complications, particularly hypertrophic scarring, and it now forms an important part of our facelift practice. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Frequently Asked Questions about Drug Testing in Schools
... Drug Testing in Schools Frequently Asked Questions About Drug Testing in Schools Email Facebook Twitter Revised May 2017 How do some schools conduct drug testing? Following models established in the workplace, some ...
78 FR 54178 - Virginia: Final Authorization of State Hazardous Waste Management Program Revisions
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-03
...] Perform inspections, and require monitoring, tests, analyses or reports; [cir] Enforce RCRA requirements... (revision Federal Register Analogous Virginia checklists \\1\\) authority RCRA Cluster XVII Hazardous Waste... Cluster XVIII Regulation of Oil-Bearing 73 FR 57, January 9 VAC Sec. Sec. 20- Hazardous Secondary...
A Revised Class Play Method of Peer Assessment.
ERIC Educational Resources Information Center
Masten, Ann S.; And Others
1985-01-01
Revised Class Play (RCP) was presented as a measure of peer reputation designed to improve the assessment of social competence as well as the psychometric properties of class play method. Administered to third through sixth graders three test dimensions were revealed: sociability-leadership, aggressive-disruptive, and sensitive-isolated. Data…
Psychometric Properties of the Revised Teachers' Attitude toward Inclusion Scale
ERIC Educational Resources Information Center
Monsen, Jeremy J.; Ewing, Donna L.; Boyle, James
2015-01-01
This paper presents the psychometric properties of a questionnaire measure that updates and extends Larrivee and Cook's (1979) Opinions Relative to Mainstreaming Scale in terms of structure, terminology, and language. The revised scale was tested using a sample of 106 teachers based in inclusive mainstream schools. Using Principal Component…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-26
... and certification of animal products and the inspection, testing, treatment, and certification of... DEPARTMENT OF AGRICULTURE Animal and Plant Health Inspection Service [Docket No. APHIS-2011-0014... Certification Program AGENCY: Animal and Plant Health Inspection Service, USDA. ACTION: Revision and extension...
Measuring Social Competence with the Wechsler Picture Arrangement and Comprehension Subtests.
ERIC Educational Resources Information Center
Campbell, Jonathan M.; McCord, David M.
1999-01-01
Tested the traditional assumption that the Wechsler Adult Intelligence Scale-Revised and the Wechsler Intelligence Scale for Children-Revised Picture Arrangement and Comprehension subtests are measures of social competence using scores from 136 children and adolescents. Cautions against interpreting either subtest as an indicator of social…
Psychometric Properties of the Revised Mathematics Anxiety Rating Scale
ERIC Educational Resources Information Center
Baloglu, Mustafa; Zelhart, Paul F.
2007-01-01
An exploratory factor analysis and several confirmatory analyses were performed to evaluate the factorial structure of the Revised Mathematics Anxiety Rating Scale (RMARS) through the responses of 805 college students. On 559 students' scores, the instrument's construct validity was tested through a confirmatory factor analysis (CFA) and was found…
Saper, Michael; Pearce, Stephanie; Shung, Joseph; Zondervan, Robert; Ostrander, Roger; Andrews, James R.
2018-01-01
Background: The number of adolescent anterior cruciate ligament (ACL) injuries is rising with increased participation in higher level athletics at earlier ages. With an increasing number of primary ACL reconstructions (ACLRs) comes a rise in the incidence of revision ACLRs. Purpose: To evaluate the clinical results of revision ACLR across a group of high-level adolescent athletes with at least 2-year follow-up. Study Design: Case series; Level of evidence, 4. Methods: A retrospective review of 21 adolescent athletes (age range, 10-19 years) who underwent revision ACLR with at least 2-year follow-up was conducted. Patient-reported outcome measures (PROMs) included the International Knee Documentation Committee (IKDC) Subjective Knee Evaluation Form, Lysholm knee scoring scale, Tegner activity level scale, and modified Cincinnati Knee Rating System. Return to sport (RTS) and overall patient satisfaction were also assessed. Results: The mean age at the time of surgery was 16.5 years (range, 14-19 years), and the mean follow-up was 46.4 months (range, 24-97 months); 42.9% of patients were female, and 52.4% of patients participated in collision sports. The mean time to failure after primary ACLR was 13.1 ± 8.0 months, and the most common mechanism of failure was noncontact in at least 66.7% of cases. The revision graft type included bone–patellar tendon–bone (BPTB) in 71.4% of cases; 26.7% of BPTB grafts were from the contralateral extremity. Concomitant procedures were performed for intra-articular lesions in 71.4% of patients. The mean patient satisfaction rate was 95.3%. There were 3 cases of a graft reinjury at a mean of 25 months postoperatively. The mean PROM scores were as follows: IKDC, 87.5 ± 12.7; Tegner, 7.2 ± 2.0; Lysholm, 93.7 ± 9.8; and Cincinnati, 93.4 ± 10.0. Of those attempting to RTS, 68.4% of patients successfully returned at the same level of competition. Patients with a lateral compartment chondral injury were less likely to RTS (P < .05). Independent variables shown to have no significant relationship to PROMs or RTS included age, follow-up, sport classification, associated meniscal tears, revision graft size/type, and concomitant procedures. Conclusion: Revision ACLR can be an effective surgical option in adolescents participating in collision and contact sports, with good to excellent subjective outcome scores. At a minimum 2-year follow-up, a graft rupture after revision ACLR occurred in 14% of cases. Of the athletes attempting to RTS, 68.4% returned to their preinjury level of competition. PMID:29662910
Intelligence, memory, and handedness in pedophilia.
Cantor, James M; Blanchard, Ray; Christensen, Bruce K; Dickey, Robert; Klassen, Philip E; Beckstead, A Lee; Blak, Thomas; Kuban, Michael E
2004-01-01
A sample of 473 male patients with pedophilia (assessed by the patients' sexual history and penile response in the laboratory to standardized, erotic stimuli) or other problematic sexual interests or behaviors received brief neuropsychological assessments. Neuropsychological measures included a short form of the Wechsler Adult Intelligence Scale--Revised (D. Wechsler, 1981), the Hopkins Verbal Learning Test--Revised (R. H. B. Benedict, D. Schretlen. L. Groninger. & J. Brandt, 1998), the Brief Visuospatial Memory Test--Revised (R. H. B. Benedict, 1997), and the Edinburgh Handedness Inventory (S. M. Williams, 1986). Pedophilia showed significant negative correlations with IQ and immediate and delayed recall memory. Pedophilia was also related to non-right-handedness even after covarying age and IQ. These results suggest that pedophilia is linked to early neurodevelopmental perturbations. ((c) 2004 APA, all rights reserved)
2008-01-03
This final rule delays until January 1, 2009 the applicability of the anti-markup provisions in Sec. 414.50, as revised at 72 FR 66222, except with respect to the technical component of a purchased diagnostic test and with respect to any anatomic pathology diagnostic testing services furnished in space that: Is utilized by a physician group practice as a "centralized building" (as defined at Sec. 411.351 of this chapter) for purposes of complying with the physician self-referral rules; and does not qualify as a "same building" under Sec. 411.355(b)(2)(i) of this chapter.
NASA Technical Reports Server (NTRS)
Banks, Bruce A.; deGroh, Kim K.; Stueber, Thomas J.; Sechkar, Edward A.; Hall, Rachelle L.
1998-01-01
Metallized Teflon fluorinated ethylene propylene (FEP) thermal control insulation is mechanically degraded if exposed to a sufficient fluence of soft x-ray radiation. Soft x-ray photons (4-8 A in wavelength or 1.55 - 3.2 keV) emitted during solar flares have been proposed as a cause of mechanical properties degradation of aluminized Teflon FEP thermal control insulation on the Hubble Space Telescope (HST). Such degradation can be characterized by a reduction in elongation-to-failure of the Teflon FEP. Ground laboratory soft x-ray exposure tests of aluminized Teflon FEP were conducted to assess the degree of elongation degradation which would occur as a result of exposure to soft x-rays in the range of 3-10 keV. Tests results indicate that soft x-ray exposure in the 3-10 keV range, at mission fluence levels, does not alone cause the observed reduction in elongation of flight retrieved samples. The soft x-ray exposure facility design, mechanical properties degradation results and implications will be presented.
Louisiana SIP: LAC 33:III Ch 61 Subchap A, §6121 to § 6131--Method 43 - Capture Efficiency Test Procedures; SIP effective 1994-06-06 (LAc60) to to 2011-08-03 (LAd34 - Moved to Chap 21 Subchap N §§ 2155-2160 and revised)
Nursing mathematics: the importance of application.
Hutton, B M
This study explores the effectiveness of a revision programme in nursing mathematics for student nurses. Students who took the revision programme achieved a marked improvement in test results, although some still scored low in written tests. When interviewed, the students reported that they had difficulty applying written work in the classroom to actual calculations in the workplace. They found that only by 'doing' mathematics did the theory make sense. The author recommends that students should be encouraged to maximise the opportunities to practise mathematics in the clinical setting.
The revised scale for caregiving self-efficacy: reliability and validity studies.
Steffen, Ann M; McKibbin, Christine; Zeiss, Antonette M; Gallagher-Thompson, Dolores; Bandura, Albert
2002-01-01
Two samples of family caregivers (Study 1: N = 169; Study 2: N = 145) of cognitively impaired older adults were used to revise, extend, and evaluate a measure of perceived self-efficacy for caregiving tasks. The Revised Scale for Caregiving Self-Efficacy measures 3 domains of caregiving self-efficacy: Obtaining Respite, Responding to Disruptive Patient Behaviors, and Controlling Upsetting Thoughts. The 3 subscales show strong internal consistency and adequate test-retest reliability. Construct validity is supported by relationships between these 3 facets of perceived caregiving efficacy and depression, anxiety, anger, perceived social support, and criticism expressed in speech samples. The Revised Scale for Caregiving Self-Efficacy has potential uses for both research and clinical purposes.
Chen, Can; Shang, Fujun; Wang, Jiepin; Chen, Jianghong; Ji, Na; Wan, Yi
2012-12-01
This study aimed to evaluate the performance of the iHealth BP3 upper-arm blood pressure monitor, which is designed for clinic use and self-measurement of blood pressure using Apple touch devices as an interface. The European Society of Hypertension International Protocol (ESH-IP) revision 2010 for the validation of blood pressure measuring devices in adults was followed precisely. Ninty-nine couples of test device and reference blood pressure measurements were obtained during the study (three pairs for each of the 33 participants). The 33 participants, age 47.1±12.3 years (age range 27-69 years) and arm circumference 30.0±4.4 cm, had a mean systolic blood pressure (SBP) of 143.9±27.4 mmHg and a mean diastolic blood pressure (DBP) of 90.1±18.3 mmHg. The device passed all of the requirements fulfilling the standards of the protocol, and the mean±SD device-observer difference was 2.8±4.2 mmHg for SBP and -0.4±3.5 mmHg for DBP. According to the results of the validation study on the basis of the ESH-IP revision 2010, the iHealth BP3 can be recommended for clinic use and self-measurement in an adult population. © 2012 Wolters Kluwer Health | Lippincott Williams & Wilkins.
Revised radiometric calibration technique for LANDSAT-4 Thematic Mapper data
NASA Technical Reports Server (NTRS)
Murphy, J.; Butlin, T.; Duff, P.; Fitzgerald, A.
1984-01-01
Depending on detector number, there are random fluctuations in the background level for spectral band 1 of magnitudes ranging from 2 to 3.5 digital numbers (DN). Similar variability is observed in all the other reflective bands, but with smaller magnitude in the range 0.5 to 2.5 DN. Observations of background reference levels show that line dependent variations in raw TM image data and in the associated calibration data can be measured and corrected within an operational environment by applying simple offset corrections on a line-by-line basis. The radiometric calibration procedure defined by the Canadian Center for Remote Sensing was revised accordingly in order to prevent striping in the output product.
Lee, Soo Cheng; Moy, Foong Ming; Hairi, Noran Naqiah
2017-01-01
The multidimensional scale of perceived social support (MSPSS) was developed to measure perceived social support. It has been translated and culturally adapted among natives literate in the Malay language. However, its psychometric properties for teachers who are majority females and married have not been assessed. This was a cross-sectional study conducted among the public secondary school teachers in the central region of Peninsular Malaysia from May to July 2013. A total of 150 and 203 teachers were recruited to perform exploratory factor analysis and confirmatory factor analysis (CFA), respectively. Reliability testing was evaluated on 141 teachers via internal consistency and two-week interval test-retest. The 12-item three-factor structure of MSPSS-M was revised to 8-item two-factor structure. The revised MSPSS-M demonstrated excellent fit in CFA with adequate divergent and convergent validity and good factor loadings (0.80-0.90). The revised MSPSS-M also displayed good internal consistency with Cronbach's alpha of 0.91, 0.93 and 0.92 and good test-retest reliability with intraclass correlation of 0.89, 0.88 and 0.88 in the total scale, family and friends factors, respectively. The revised 8-item MSPSS-M is a reliable and valid tool for assessment of perceived social support among teachers.
Update on CMH-17 Volume 5: Ceramic Matrix Composites
NASA Technical Reports Server (NTRS)
David, Kaia; Pierce, Jennifer; Kiser, James; Keith, William P.; Wilson, Gregory S.
2015-01-01
CMC components are projected to enter service in commercial aircraft in 2016. A wide range of issues must be addressed prior to certification of this hardware. The Composite Materials Handbook-17, Volume 5 on ceramic matrix composites is being revised to support FAA certification of CMCs for hot structure and other elevated temperature applications. The handbook supports the development and use of CMCs through publishing and maintaining proven, reliable engineering information and standards that have been thoroughly reviewed. Volume 5 will contain detailed sections describing CMC materials processing, design analysis guidelines, testing procedures, and data analysis and acceptance. A review of the status of and plans for two of these areas, which are being addressed by the M and P Working Group and the Testing Working Group, will be presented along with a timeline for the preparation of CMH-17, Volume 5.
Resch, Jacob E; Brown, Cathleen N; Schmidt, Julianne; Macciocchi, Stephen N; Blueitt, Damond; Cullum, C Munro; Ferrara, Michael S
2016-01-01
A battery of clinical measures of neurocognition, balance and symptoms has been recommended for the management of sport concussion (SC) but is based on variable evidence. To examine the sensitivity and specificity of a battery of tests to assess SC in college athletes. Cross-sectional. Research laboratory. Division 1 athletes diagnosed with a SC (n=40) who were 20.2±1.60 years of age and 180.5±11.12 cm tall and healthy athletes (n=40) who were 19.0±0.93 years of age and 179.1±11.39 cm tall were enrolled. Participants were administered Immediate Postconcussion Assessment and Cognitive Test (ImPACT), the Sensory Organization Test (SOT) and the Revised Head Injury Scale (HIS-r) prior to and up to 24 h following injury between the 2004 and 2014 sport seasons. Sensitivity and specificity were calculated using predictive discriminant analyses (PDA) and clinical interpretation guidelines. Outcome measures included baseline and postinjury ImPACT, SOT and HIS-r composite scores. Using PDA, each clinical measure's sensitivity ranged from 55.0% to 77.5% and specificity ranged from 52.5% to 100%. The test battery possessed a sensitivity and specificity of 80.0% and 100%, respectively. Using clinical interpretation guidelines, sensitivity ranged from 55% to 97.5% individually, and 100% when combined. Our results support a multidimensional approach to assess SC in college athletes which correctly identified 80-100% of concussed participants as injured. When each test was evaluated separately, up to 47.5% of our sample was misclassified. Caution is warranted when using singular measures to manage SC.
Resch, Jacob E; Brown, Cathleen N; Schmidt, Julianne; Macciocchi, Stephen N; Blueitt, Damond; Cullum, C Munro; Ferrara, Michael S
2016-01-01
Context A battery of clinical measures of neurocognition, balance and symptoms has been recommended for the management of sport concussion (SC) but is based on variable evidence. Objective To examine the sensitivity and specificity of a battery of tests to assess SC in college athletes. Design Cross-sectional. Setting Research laboratory. Patients or other participants Division 1 athletes diagnosed with a SC (n=40) who were 20.2±1.60 years of age and 180.5±11.12 cm tall and healthy athletes (n=40) who were 19.0±0.93 years of age and 179.1±11.39 cm tall were enrolled. Intervention(s) Participants were administered Immediate Postconcussion Assessment and Cognitive Test (ImPACT), the Sensory Organization Test (SOT) and the Revised Head Injury Scale (HIS-r) prior to and up to 24 h following injury between the 2004 and 2014 sport seasons. Sensitivity and specificity were calculated using predictive discriminant analyses (PDA) and clinical interpretation guidelines. Main outcome measures Outcome measures included baseline and postinjury ImPACT, SOT and HIS-r composite scores. Results Using PDA, each clinical measure's sensitivity ranged from 55.0% to 77.5% and specificity ranged from 52.5% to 100%. The test battery possessed a sensitivity and specificity of 80.0% and 100%, respectively. Using clinical interpretation guidelines, sensitivity ranged from 55% to 97.5% individually, and 100% when combined. Conclusions Our results support a multidimensional approach to assess SC in college athletes which correctly identified 80–100% of concussed participants as injured. When each test was evaluated separately, up to 47.5% of our sample was misclassified. Caution is warranted when using singular measures to manage SC. PMID:27900145
Bokhorst, Leonard P; Roobol, Monique J; Bangma, Chris H; van Leenders, Geert J
2017-07-01
To investigate if pathologic biopsy reevaluation and implementation of immunohistochemical biomarkers could improve prediction of radical prostatectomy outcome in men initially on active surveillance. Biopsy specimens from diagnosis until switching to radical prostatectomy in men initially on active surveillance in the Dutch part of the Prostate cancer Research International Active Surveillance (PRIAS) study were collected and revised by a single pathologist. Original and revised biopsy Gleason score were compared and correlated with radical prostatectomy Gleason score. Biopsy specimens were immunohistochemically stained for Ki67 and ERG. Predictive ability of clinical characteristics and biomarkers on Gleason ≥7 or ≥pT3 on radical prostatectomy was tested using logistic regression and ROC curve analysis. A total of 150 biopsies in 95 men were revised. In 13% of diagnostic or second-to-last biopsies and 20% of the last biopsies on active surveillance revision of Gleason score resulted in change of recommendation (ie, active treatment or active surveillance). Concordance with Gleason score on radical prostatectomy was however similar for both the revised and original Gleason on biopsy. Ki67 and ERG were not statistically significant predictors of Gleason ≥7 or ≥pT3 on radical prostatectomy. Although interobserver differences in pathology reporting on biopsy could result in a change of management strategy in approximately 13-20% of men on active surveillance, both pathological revision and tested biomarkers (Ki67 and ERG) did not improve prediction of outcome on radical prostatectomy. Undersampling of most aggressive tumor remains the main focus in order to increase accurate grading at time of treatment decision making. © 2017 Wiley Periodicals, Inc.
A new amperometric glucose microsensor: in vitro and short-term in vivo evaluation.
Ward, W Kenneth; Jansen, Lawrence B; Anderson, Ellen; Reach, Gerard; Klein, Jean-Claude; Wilson, George S
2002-03-01
For biosensor fabrication, it is important to optimize materials and methods in order to create predictable function in vitro and in vivo. For this reason, we designed a new glucose sensor ('revised protocol') that utilized an outer permselective membrane made of amphiphobic polyurethane which allows glucose passage through hydrophilic segments. An inner polyethersulfone membrane, stabilized with a trimethoxysilane, provided specificity. Before application of the inner membrane, it was necessary to etch the platinum electrode with a radio frequency oxygen plasma. The revised protocol sensors (n=185) were compared with sensors fabricated with an earlier ('original') protocol (n=204) which used an outer polyurethane without hydrophilic segments and a complex inner membrane of cellulose acetate and Nafion. The function of revised protocol sensors was more predictable in vitro as evidenced by a much lower variation of glucose sensitivity than the original protocol sensors. Revised and original protocol sensors were nearly linear up to a glucose concentration of 20 mM. In vitro interference from 0.1 mM acetaminophen was minimal in both groups of sensors and would be expected to represent about 2% of the total sensor response at normal glucose levels for revised protocol sensors. Prolonged testing of the revised protocol sensors for 11 days during immersion in buffer revealed stable sensitivities (day 1: 6.12+/-1.34 nA/mM; day 3: 6.33+/-1.40; day 8: 7.13+/-1.39; and day 11: 7.56+/-1.47; sensitivity for day 1 vs. each other day: not significant) and no critical loss of glucose oxidase activity. The response of the revised protocol sensors (n=7) to intraperitoneal glucose was tested in rats approximately one day after subcutaneous implantation and the sensors tracked glucose closely with a slight lag of 3-6 min.
Romanò, Carlo L; Monti, Lorenzo; Logoluso, Nicola; Romanò, Delia; Drago, Lorenzo
2015-11-01
The aim of the present study was to assess the efficacy of a thrombin-based topical haemostatic in reducing blood requirements after total knee replacement (TKR) revision surgery. This prospective, randomized, controlled study was designed to evaluate the haemostatic efficacy and safety of a thrombin-based topical haemostatic (Floseal) versus standard treatment in patients receiving total knee revision arthroplasty. The decrease in haemoglobin values postsurgery and the blood units transfused were recorded. The decision to transfuse was made by a surgeon blinded to the patient's group allocation. Forty-eight patients were enroled in the study; twenty-four patients each were randomized to the treatment and control groups, respectively. The median decrease in haemoglobin concentration on the first postoperative day was 2.2 g/dL in the treatment group and 2.7 g/dL in the control group. A significant reduction in units of blood transfused was also observed in the treatment group compared with the control group [1.1 ± 1.13 (range 0-4) vs. 1.9 ± 1.41 (range 0-5) blood units; P = 0.04]. No major treatment-related adverse events were recorded in the study. This study shows that a thrombin-based topical haemostatic reduces the need for blood transfusion in TKR revision surgery. A thrombin-based topical haemostatic agent can be an appropriate solution to enhance haemostasis and vessel sealing at the operative site in TKR revision surgery, in order to reduce the need for blood transfusion after surgery. II.
Radiographic Findings in Revision Anterior Cruciate Ligament Reconstructions from the MARS Cohort
2013-01-01
The Multicenter ACL (anterior cruciate ligament) Revision Study (MARS) group was developed to investigate revision ACL reconstruction outcomes. An important part of this is obtaining and reviewing radiographic studies. The goal for this radiographic analysis is to establish radiographic findings for a large revision ACL cohort to allow comparison with future studies. The study was designed as a cohort study. Various established radiographic parameters were measured by three readers. These included sagittal and coronal femoral and tibial tunnel position, joint space narrowing, and leg alignment. Inter- and intraobserver comparisons were performed. Femoral sagittal position demonstrated 42% were more than 40% anterior to the posterior cortex. On the sagittal tibia tunnel position, 49% demonstrated some impingement on full-extension lateral radiographs. Limb alignment averaged 43% medial to the medial edge of the tibial plateau. On the Rosenberg view (45-degree flexion view), the minimum joint space in the medial compartment averaged 106% of the opposite knee, but it ranged down to a minimum of 4.6%. Lateral compartment narrowing at its minimum on the Rosenberg view averaged 91.2% of the opposite knee, but it ranged down to a minimum of 0.0%. On the coronal view, verticality as measured by the angle from the center of the tibial tunnel aperture to the center of the femoral tunnel aperture measured 15.8 degree ± 6.9% from vertical. This study represents the radiographic findings in the largest revision ACL reconstruction series ever assembled. Findings were generally consistent with those previously demonstrated in the literature. PMID:23404491
Does a cemented cage improve revision THA for severe acetabular defects?
Hansen, Erik; Shearer, David; Ries, Michael D
2011-02-01
Evidence suggests a growing incidence of revision total hip arthroplasty (THA) including a subset with large acetabular defects. Revision THA for severe acetabular bone loss is associated with a relatively high rate of mechanical failure. We questioned whether cementing a cage to the reconstructed acetabular defect and pelvis would improve the rate of mechanical failure for patients with Type 3 defects (Paprosky et al.) with and without pelvic discontinuity in comparison to historical controls. We retrospectively collected data on 33 patients who underwent 35 revision THAs using an acetabular reconstruction cage cemented to morselized allograft and either structural allograft or trabecular metal augmentation for Type 3 defects in the presence (n = 13) and absence (n = 22) of pelvic discontinuity at a mean followup of 59 months (range, 24-92 months). The primary outcome was mechanical failure, defined as revision of the acetabular reconstruction for aseptic loosening. Revision surgery for mechanical failure occurred in four of the 13 patients with pelvic discontinuity and two of the 22 patients without discontinuity. Radiographic loosening occurred in one patient with and one patient without pelvic discontinuity. Seven of the 35 revisions were subsequently revised for deep infection all in patients who were immunocompromised. Cementing the cage to the pelvis can offer an advantage for treating severe acetabular defects. Trabecular metal augmentation appears to provide better initial mechanical stability than a structural allograft, but successful allograft reconstruction may restore bone stock. Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Barrow, Paul
2016-09-01
SWOT analysis was used to gain insights and perspectives into the revision of the ICH S5(R2) guideline on detection of toxicity to reproduction for medicinal products. The current ICH guideline was rapidly adopted worldwide and has an excellent safety record for more than 20 years. The revised guideline should aim to further improve reproductive and developmental (DART) safety testing for new drugs. Alternative methods to animal experiments should be used whenever possible. Modern technology should be used to obtain high quality data from fewer animals. Additions to the guideline should include considerations on the following: limit dose setting, maternal toxicity, biopharmaceuticals, vaccines, testing strategies by indication, developmental immunotoxicity, and male-mediated developmental toxicity. Emerging issues, such as epigenetics and the microbiome, will most likely pose challenges to DART testing in the future. It is hoped that the new guideline will be adopted even outside the ICH regions. Copyright © 2016 Elsevier Inc. All rights reserved.
Umar, Asad; Boland, C. Richard; Terdiman, Jonathan P.; Syngal, Sapna; de la Chapelle, Albert; Rüschoff, Josef; Fishel, Richard; Lindor, Noralane M.; Burgart, Lawrence J.; Hamelin, Richard; Hamilton, Stanley R.; Hiatt, Robert A.; Jass, Jeremy; Lindblom, Annika; Lynch, Henry T.; Peltomaki, Païvi; Ramsey, Scott D.; Rodriguez-Bigas, Miguel A.; Vasen, Hans F. A.; Hawk, Ernest T.; Barrett, J. Carl; Freedman, Andrew N.; Srivastava, Sudhir
2010-01-01
Hereditary nonpolyposis colorectal cancer (HNPCC), also known as Lynch syndrome, is a common autosomal dominant syndrome characterized by early age at onset, neoplastic lesions, and microsatellite instability (MSI). Because cancers with MSI account for approximately 15% of all colorectal cancers and because of the need for a better understanding of the clinical and histologic manifestations of HNPCC, the National Cancer Institute hosted an international workshop on HNPCC in 1996, which led to the development of the Bethesda Guidelines for the identification of individuals with HNPCC who should be tested for MSI. To consider revision and improvement of the Bethesda Guidelines, another HNPCC workshop was held at the National Cancer Institute in Bethesda, MD, in 2002. In this commentary, we summarize the Workshop presentations on HNPCC and MSI testing; present the issues relating to the performance, sensitivity, and specificity of the Bethesda Guidelines; outline the revised Bethesda Guidelines for identifying individuals at risk for HNPCC; and recommend criteria for MSI testing. PMID:14970275
Evaluation and revision of questionnaires for use among low-literacy immigrant Latinos
D'Alonzo, Karen T.
2011-01-01
As more Spanish speaking immigrants participate in and become the focus of research studies, questions arise about the appropriateness of existing research tools. Questionnaires have often been adapted from English language instruments and tested among college- educated Hispanic-Americans. Little has been written regarding the testing and evaluation of research tools among less educated Latino immigrants. The purpose of this study was to revise and evaluate the appropriateness of a battery of existing Spanish-language questionnaires for a physical activity intervention for immigrant Hispanic women. A three-step process was utilized to evaluate, adapt and test Spanish versions of the Self-Efficacy and Exercise Habits Survey, an abbreviated version of the Hispanic Stress Inventory-Immigrant version and the Latina Values Scale. The revised tools demonstrated acceptable validity and reliability. The adaptations improved the readability of the tools, resulting in a greater response rate, less missing data and fewer extreme responses. Psychometric limitations to the adaptation of Likert scales are discussed. PMID:22030592
Isosu, Tsuyoshi; Obara, Shinju; Hakozaki, Takahiro; Imaizumi, Tsuyoshi; Iseki, Yuzo; Mogami, Midori; Ohashi, Satoshi; Ikegami, Yukihiro; Kurosawa, Shin; Murakawa, Masahiro
2017-04-01
The effects of intravenous injection of indigo carmine on noninvasive and continuous total hemoglobin (SpHb) measurement were retrospectively evaluated with the Revision L sensor. The subjects were 18 patients who underwent elective gynecologic surgery under general anesthesia. During surgery, 5 mL of 0.4 % indigo carmine was injected intravenously, and changes in SpHb concentrations between before and after the injection were evaluated. The mean age was 52.4 ± 12.8 years. Before injection, the median SpHb level was 10.1 (range, 6.8-13.4) g/dL. The results demonstrated no change in SpHb concentration between before and after indigo carmine injection as detected by the Revision L sensor. SpHb measurements as determined with the Revision L sensor were not affected, even after the intravenous injection of indigo carmine.
Hip fusion takedown to a total hip arthroplasty-is it worth it? A systematic review.
Jauregui, Julio J; Kim, Joseph K; Shield, William P; Harb, Matthew; Illical, Emmanuel M; Adib, Farshad; Maheshwari, Aditya V
2017-08-01
Patients with surgically or spontaneously fused hips are often dissatisfied with their overall function and the debilitating effect on adjacent joints. Therefore, in properly selected patients, hip fusion-takedown and conversion to total hip arthroplasty (THA) can result in improved function and decreased pain. We aimed to (1) evaluate the indications for conversion, (2) evaluate the clinical outcomes, (3) analyze the overall complications, and (4) identify the overall satisfaction following the procedure. A systematic and comprehensive literature search was performed to analyze studies evaluating conversion of hip fusion to THA. After reviewing 3,882 studies, 27 total studies (1,104 hips) met our inclusion/exclusion criteria and were included in our final analysis. A weighted mean of rates was determined for each complication, including infection, instability, loosening, nerve-related, abductor-related, venous thrombotic event, and revision. The study population consisted of 53.2% male and 46.8% female subjects. The mean age at time of conversion was 52 years (range 36-65 years), the mean time until follow-up was 9.2 years (range 2.5-17.3), and the mean duration of arthrodesis was 27.7 years (range 11-40.2). As measured by Harris Hip Score, overall clinical outcomes improved from 58.1 points (range 42.4-70 points) pre-operatively to 80.0 (range 62-93.5) post-operatively. The specific complication rates were 5.3% (range 0-43.6%) for infection, 2.6% (range 0-15.4%) for instability, 6.2% (range 0-17.2%) for loosening, 4.7% (range 0-13%) for nerve-related complications, 13.1% (range 0-87%) for abductor-related complications, and 1.2% (range 0-13%) for venous thrombotic events. The revision rate was 12.0% (range 0-43.6%). Takedown of a fused-hip can be a challenging procedure. Although patients can benefit functionally, both patients and surgeons need to be aware of the complications and increased risk of further revision procedures, which should be an important part of the pre-operative discussion.
Beime, Beate; Deutsch, Cornelia; Krüger, Ralf; Wolf, Andreas; Müller, Peter; Hammel, Gertrud; Bramlage, Peter
2017-05-01
The purpose of the study was to validate the ambulatory blood pressure monitoring (ABPM) device custo screen pediatric in children aged 3 to 12 years according to the International Protocol of the European Society of Hypertension (ESH-IP revision 2010). Thirty-three children were included and systolic and diastolic blood pressure measurements were performed according to the ESH-IP. The protocol was modified for children considering data from the German Health Interview and Examination Survey for Children and Adolescents (KIGGS). The custo screen pediatric met all the requirements of the ESH-IP. The mean difference between the test device and the reference was -1.4 ± 3.0 mmHg for systolic blood pressure (SBP) and -0.7 ± 3.2 mmHg for diastolic blood pressure (DBP). For SBP and DBP, all 99 measurements were within the absolute difference of 10 mmHg between the test device and the reference. As to part 2 of the protocol, for DBP in all subjects, two out of three measurements were within 5 mmHg between the device and the standard, whereas for SBP in 32 of 33 subjects, two out of three measurements were within this range. The custo screen pediatric met all criteria of the ESH-IP review 2010, modified for children from 3 to about 12 years, and can be recommended for ABPM in children. What is Known: • Validation of blood pressure measuring devices is essential to provide patients with an accurate blood pressure measuring device. • The majority of devices has not been validated in children. What is New: • Prior to the present validation, study protocol adjustments of ESH-IP review 2010 for children were defined according to German Health Interview and Examination Survey for Children and Adolescents 2013 (KIGGS). • The custo screen pediatric test device met all criteria of ESH-IP revision 2010, modified for children, and can be recommended for ABPM in children aged 3 to about 12 years.
Aksoy Derya, Yeşim; Timur Taşhan, Sermin; Duman, Mesude; Durgun Ozan, Yeter
2018-07-01
The purpose of this study was to create a Turkish version of the Pregnancy-Related Anxiety Questionnaire-Revised 2 (PRAQR2), which was revised for application to multiparous and primiparous pregnancy, and to explore its psychometric characteristics in multiparous and primiparous pregnancy. This study was methodologically designed to assess the reliability and validity of the PRAQ-R2. The study was carried out in the obstetrics clinic of a training and research hospital in Malatya. A total of 616 healthy pregnant women (399 multiparous and 217 primiparous) constituted the sample of the study. The cultural adaptation process of the questionnaire was conducted in three phases: language validity, content validity, and pilot application. Exploratory factor analysis (EFA) and confirmatory factor analysis (CFA) were used to test the construct validity of the questionnaire. The reliability of the PRAQ-R2 was evaluated with Cronbach's alpha internal consistency coefficient, item-total correlation, test-retest analysis, and parallel forms reliability. The EFA revealed that the PRAQ-R2 consists of 10 items for the multiparous group and 11 for the primiparous group after adding the item ``I am anxious about the delivery because I have never experienced one before.'' The CFA for both groups supported the three-factor questionnaire yielded by the EFA. Good fit index values were obtained in both groups. Cronbach's alpha internal consistency coefficient ranged from 0.81 to 0.93 for the multiparous group and 0.87 to 0.94 for the primiparous group for the complete PRAQ-R2 and each of its subdimensions. In addition, the item-total correlation, test-retest analysis, and parallel forms reliability of the questionnaire were highly correlated. The PRAQ-R2 is a valid and reliable instrument that can be used to evaluate the level of anxiety in Turkish pregnant women irrespective of parity. The use of the PRAQ-R2 in prenatal healthcare services will contribute to the early diagnosis, treatment, and management of pregnancy-related anxiety. Copyright © 2018 Elsevier Ltd. All rights reserved.
49 CFR 232.603 - Design, interoperability, and configuration management requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
...: 1999; Revised 2002, 2007); (3) AAR S-4220, “ECP Cable-Based Brake DC Power Supply—Performance...; Revised: 2004); (7) AAR S-4260, “ECP Brake and Wire Distributed Power Interoperability Test Procedures...) Approval. A freight train or freight car equipped with an ECP brake system and equipment covered by the AAR...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-08
... this rule. F. Revision of 40 CFR 1065.915 To Allow the Use of ECM Fuel Rate To Determine NTE Mass... electronic control module (ECM) along with other information, including the CO 2 , CO, and hydrocarbon... all large horsepower nonroad diesel engines will [[Page 68580
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-20
... DEPARTMENT OF AGRICULTURE Agricultural Marketing Service [AMS-CN-10-0038, CN-10-002] Cotton... Management and Budget, for an extension and revision to the currently approved information collection Cotton... Shethir Riva, Chief, Research and Promotion, Cotton and Tobacco Programs, Agricultural Marketing Service...
Learning Assessment in Tertiary Business Education with Revised Taxonomy
ERIC Educational Resources Information Center
Hossain, Md. Shajjad
2017-01-01
The goal of this study was to evaluate the assessment criteria of learning in tertiary education of Bangladesh. The study was aimed at identifying percentage of questions during learning assessment of business graduates following cognitive levels of Bloom's in revised Taxonomy and to test whether there was any significant difference in the…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-02
... pregnant women and for children who are the subjects of observational research conducted or supported by... whether human testing is necessary given other methods of research. E. Settlement of the Litigation After... Revisions to EPA's Rule on Protections for Subjects in Human Research Involving Pesticides AGENCY...
78 FR 18837 - Revised Medical Criteria for Evaluating Visual Disorders
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-28
... introductory text. Vision Testing Comment: One commenter suggested that we maintain the specific references to the Humphrey Field Analyzer (HFA) and Octopus perimeters that were provided in the introductory text... note). 0 2. Amend appendix 1 to subpart P of part 404 by: 0 a. Revising item 3 of the introductory text...
Designing User Manuals for the Online Public Access Catalog.
ERIC Educational Resources Information Center
Seiden, Peggy; Sullivan, Patricia
1986-01-01
Describes the process of developing and revising a brochure to guide library patrons in conducting an author search on an online public access catalog in order to demonstrate the application of four steps in production of a functional document--analysis; planning; development; evaluation, testing, and revision. Three sources are given. (EJS)
Experimental Forests and Ranges of the USDA Forest Service
Mary Beth Adams; Linda Loughry; Linda, comps. Plaugher
2008-01-01
The USDA Forest Service has an outstanding scientific resource in the 77 Experimental Forests and Ranges that exist across the United States and its territories. These valuable scientific resources incorporate a broad range of climates, forest types, research emphases, and history. This publication, revised in March 2008, describes each of the research sites within the...
Executive function in cancer patients with posttraumatic stress disorder.
Yang, Juan; Guo, Juncheng; Jiang, Xiangling
2017-03-01
Background Cancer patients with posttraumatic stress disorder can lead to their noncompliant behaviors. However, less is known about the neurocognitive functioning of posttraumatic stress disorder in general cancer types or patient populations. The current study attempted to examine the prevalence of posttraumatic stress disorder and their relationships with executive function in individuals with cancer. Methods A total of 285 cancer patients with posttraumatic stress disorder and 150 healthy individuals were recruited for the present study. The Clinician Administered PTSD Scale, Tower of Hanoi, Wisconsin Card Sorting Test, and Wechsler Adult Intelligence Scale-Revised Chinese revision were administered to all participants. Results Significant differences in the score of Tower of Hanoi, Wisconsin Card Sorting Test, and Wechsler Adult Intelligence Scale-Revised Chinese revision were observed between the posttraumatic stress disorder group and the healthy control group ( p < 0.001). Significant correlations were found between all posttraumatic stress disorder symptoms and executive function. Conclusions These findings suggest that individuals with cancer-related posttraumatic stress disorder exhibit more severe impairment in executive function than healthy controls do.
Corrective action investigation plan: Cactus Spring Waste Trenches. Revision 2
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
This Correction Action Investigation Plan (CAIP) contains environmental sample collection objectives and logic for the CAU No. 426, which includes the Cactus Spring Waste Trenches, CAS No. RG-08-001-RG-CS. The Cactus Spring Waste Trenches are located at the Tonopah Test Range (TTR) which is part of the Nellis Air Force Range, approximately 255 kilometers (km) (140 miles [mi]) northwest of Las Vegas, Nevada, by air. The purpose of this investigation is to generate sufficient data to establish the types of waste buried in the trenches, identify the presence and nature of contamination, determine the vertical extent of contaminant migration below themore » Cactus Spring Waste Trenches, and determine the appropriate course of action for the site. The potential courses of action for the site are clean closure, closure in place (with or without remediation), or no further action.« less
Nguyen-Truong, Connie K Y; Leo, Michael C; Lee-Lin, Frances; Gedaly-Duff, Vivian; Nail, Lillian M; Gregg, Jessica; Le, Tuong Vy; Tran, Tuyen
2015-05-01
Vietnamese American women diagnosed with cervical cancer are more likely to have advanced cancer than non-Hispanic White women. We sought to (a) develop a culturally sensitive Vietnamese translation of the Revised Susceptibility, Benefits, and Barriers Scale; Cultural Barriers to Screening Inventory; Confidentiality Issues Scale; and Quality of Care from the Health Care System Scale and (b) examine the psychometric properties. Cross-sectional study with 201 Vietnamese immigrant women from the Portland, Oregon, metropolitan area. We used a community-based participatory research approach and the U.S. Census Bureau's team approach to translation. Cronbach's alpha ranged from .57 to .91. The incremental fit index ranged from .83 to .88. The instruments demonstrated moderate to strong subscale internal consistency. Further research to assess structural validity is needed. Our approaches to translation and psychometric examination support use of the instruments in Vietnamese immigrant women. © The Author(s) 2014.
Next Generation Launch Technology Program Lessons Learned
NASA Technical Reports Server (NTRS)
Cook, Stephen; Tyson, Richard
2005-01-01
In November 2002, NASA revised its Integrated Space Transportation Plan (ISTP) to evolve the Space Launch Initiative (SLI) to serve as a theme for two emerging programs. The first of these, the Orbital Space Plane (OSP), was intended to provide crew-escape and crew-transfer functions for the ISS. The second, the NGLT Program, developed technologies needed for safe, routine space access for scientific exploration, commerce, and national defense. The NGLT Program was comprised of 12 projects, ranging from fundamental high-temperature materials research to full-scale engine system developments (turbine and rocket) to scramjet flight test. The Program included technology advancement activities with a broad range of objectives, ultimate applications/timeframes, and technology maturity levels. An over-arching Systems Engineering and Analysis (SE&A) approach was employed to focus technology advancements according to a common set of requirements. Investments were categorized into three segments of technology maturation: propulsion technologies, launch systems technologies, and SE&A.
Elmengaard, Brian; Bechtold, Joan E.; Chen, Xinqian; Søballe, Kjeld
2013-01-01
Revision joint replacement has poorer outcomes that have been associated with poorer mechanical fixation. We investigate a new bone-sparing surgical technique that locally cracks the sclerotic bone rim formed during aseptic loosening. We inserted 16 hydroxyapatite-coated implants bilaterally in the distal femur of eight dogs, using a controlled weight-bearing experimental model that replicates important features of a typical revision setting. At 8 weeks, a control revision procedure and a crack revision procedure were performed on contralateral implants. The crack procedure used a splined tool to perform a systematic local perforation of the sclerotic bone rim of the revision cavity. After 4 weeks, the hydroxyapatite-coated implants were evaluated for mechanical fixation by a push-out test and for tissue distribution by histomorphometry. The cracking revision procedure resulted in significantly improved mechanical fixation, significantly more bone ongrowth and bone volume in the gap, and reduced fibrous tissue compared to the control revision procedure. The study demonstrates that the sclerotic bone rim prevents bone ingrowth and promotes fixation by fibrous tissue. The effect of the cracking technique may be due to improved access to the vascular compartment of the bone. The cracking technique is a simple surgical method that potentially can improve the fixation of revision implants in sclerotic regions important for obtaining the fixation critical for overall implant stability. PMID:19148940
Increased incidence of patella baja after total knee arthroplasty revision for infection.
Chen, Antonia F; Tetreault, Matthew W; Levicoff, Eric A; Fedorka, Catherine J; Rothenberg, Adam C; Klatt, Brian A
2014-12-01
The incidence of patella baja in total knee arthroplasty (TKA) revisions for aseptic and septic causes is not well defined. We retrospectively reviewed 101 mobile-bearing TKA revisions performed between 2003 and 2009. Aseptic (n=67) and septic (n=34) revisions were compared for patella baja. A nonarticulating spacer was used as the initial treatment for infected cases. The Insall-Salvati ratio was radiographically measured before surgery (preexplant for septic revisions) and at latest follow-up (postreplant for septic revisions). Mean (SD) Insall-Salvati ratio did not differ between groups before surgery, 1.00 (0.25) for aseptic and 0.96 (0.22) for septic, but differed significantly after surgery, 0.99 (0.23) for aseptic and 0.77 (0.24) for septic. After correcting for preoperative patellar height, there was a statistically significant postoperative difference between aseptic cases, 1.09 (0.19), and septic cases, 0.82 (0.21). There was also a significant difference in mean (SD) postoperative range of motion (ROM) between aseptic cases, 108.0° (20.7°), and septic cases, 92.2° (34.6°), and decreased ROM between cases with patella baja, 95.1° (31.6°) and cases without patella baja, 106.8° (23.6°). TKA revisions done for septic causes using a nonarticulating spacer resulted in a higher incidence of patella baja and decreased ROM.
Long-term follow-up after surgery in localized laryngeal amyloidosis.
Hazenberg, Aldert J C; Hazenberg, Bouke P C; Dikkers, Frederik G
2016-09-01
To study effectiveness of surgery and watchful waiting in localized laryngeal amyloidosis, retrospective case series. This retrospective study comprises all consecutive patients with localized laryngeal amyloidosis surgically treated in a tertiary hospital between 1994 and February 2016. Recurrence rate, revision surgery, progression to systemic amyloidosis, and changes in voice were monitored yearly. Eighteen patients were included. Seven women and eleven men had a median age 50 years (range 21-77 years) and median follow-up 6.4 years (2.4-17 years). Amyloid was located in subglottis (5), glottis (8), false vocal folds (8) and other supraglottic areas (5), in more than one laryngeal region (13) and bilaterally (12). Cold steel excision was used at the glottis; CO2 laser excision, sometimes assisted by microdebrider, at other laryngeal areas. Eleven patients needed revision surgery, ten within the first 4 years after surgical treatment. One patient needed his first revision surgery after 11 years. Five patients needed a second revision within 6 years after initial diagnosis. Two patients needed a third revision. Indications for first revision surgery were progression (8) with dysphonia (7), dyspnea (2), dysphagia (1), exclusion of malignancy (1), and aphonia (1). No patient developed systemic amyloidosis during follow-up. Although local progression of amyloid necessitates revision surgery once or twice in the first 4-6 years, progression slows down thereafter. Late progression, however, remains possible.
GPS Device Testing Based on User Performance Metrics
DOT National Transportation Integrated Search
2015-10-02
1. Rationale for a Test Program Based on User Performance Metrics ; 2. Roberson and Associates Test Program ; 3. Status of, and Revisions to, the Roberson and Associates Test Program ; 4. Comparison of Roberson and DOT/Volpe Programs
Space Construction Experiment Definition Study (SCEDS), part 2. Volume 2: Study results
NASA Technical Reports Server (NTRS)
1982-01-01
The Space Construction Experiment (SCE) was defined for integration into the Space Shuttle. This included development of flight assignment data, revision and update of preliminary mission timelines and test plans, analysis of flight safety issues, and definition of ground operations scenarios. New requirements for the flight experiment and changes for a large space antenna feed mask test article were incorporated. The program plan and cost estimates were updated. Revised SCE structural dynamics characteristics were provided for simulation and analysis of experimental tests to define and verify control limits and interactions effects between the SCE and the Orbiter digital automatic pilot.
Effect of revised high-heeled shoes on foot pressure and static balance during standing.
Bae, Young-Hyeon; Ko, Mansoo; Park, Young-Soul; Lee, Suk-Min
2015-04-01
[Purpose] The purpose of this study was to investigate the effects of revised high-heeled shoes on the foot pressure ratio and static balance during standing. [Subjects and Methods] A single-subject design was used, 15 healthy women wearing revised high-heeled shoes and general high-heeled shoes in a random order. The foot pressure ratio and static balance scores during standing were measured using a SpaceBalance 3D system. [Results] Forefoot and rearfoot pressures were significantly different between the 2 types of high-heeled shoes. Under the 3 conditions tested, the static balance score was higher for the revised high-heeled shoes than for the general high-heeled shoes, but this difference was not statistically significant. [Conclusion] Revised high-heeled shoes are preferable to general high-heeled shoes, as they result in normalization of normalized foot pressure and a positive effect on static balance.
Effect of revised high-heeled shoes on foot pressure and static balance during standing
Bae, Young-Hyeon; Ko, Mansoo; Park, Young-Soul; Lee, Suk-Min
2015-01-01
[Purpose] The purpose of this study was to investigate the effects of revised high-heeled shoes on the foot pressure ratio and static balance during standing. [Subjects and Methods] A single-subject design was used, 15 healthy women wearing revised high-heeled shoes and general high-heeled shoes in a random order. The foot pressure ratio and static balance scores during standing were measured using a SpaceBalance 3D system. [Results] Forefoot and rearfoot pressures were significantly different between the 2 types of high-heeled shoes. Under the 3 conditions tested, the static balance score was higher for the revised high-heeled shoes than for the general high-heeled shoes, but this difference was not statistically significant. [Conclusion] Revised high-heeled shoes are preferable to general high-heeled shoes, as they result in normalization of normalized foot pressure and a positive effect on static balance. PMID:25995572
Blom, Ashley W; Whitehouse, Michael R; Gooberman-Hill, Rachael
2015-01-01
Objectives Around 1% of patients who have a hip replacement have deep prosthetic joint infection (PJI) afterwards. PJI is often treated with antibiotics plus a single revision operation (1-stage revision), or antibiotics plus a 2-stage revision process involving more than 1 operation. This study aimed to characterise the impact and experience of PJI and treatment on patients, including comparison of 1-stage with 2-stage revision treatment. Design Qualitative semistructured interviews with patients who had undergone surgical revision treatment for PJI. Patients were interviewed between 2 weeks and 12 months postdischarge. Data were audio-recorded, transcribed, anonymised and analysed using a thematic approach, with 20% of transcripts double-coded. Setting Patients from 5 National Health Service (NHS) orthopaedic departments treating PJI in England and Wales were interviewed in their homes (n=18) or at hospital (n=1). Participants 19 patients participated (12 men, 7 women, age range 56–88 years, mean age 73.2 years). Results Participants reported receiving between 1 and 15 revision operations after their primary joint replacement. Analysis indicated that participants made sense of their experience through reference to 3 key phases: the period of symptom onset, the treatment period and protracted recovery after treatment. By conceptualising their experience in this way, and through themes that emerged in these periods, they conveyed the ordeal that PJI represented. Finally, in light of the challenges of PJI, they described the need for support in all of these phases. 2-stage revision had greater impact on participants’ mobility, and further burdens associated with additional complications. Conclusions Deep PJI impacted on all aspects of patients’ lives. 2-stage revision had greater impact than 1-stage revision on participants’ well-being because the time in between revision procedures meant long periods of immobility and related psychological distress. Participants expressed a need for more psychological and rehabilitative support during treatment and long-term recovery. PMID:26644124
DOE Office of Scientific and Technical Information (OSTI.GOV)
Matthews, Patrick
Corrective Action Unit (CAU) 414 is located on the Tonopah Test Range, which is approximately 130 miles northwest of Las Vegas, Nevada, and approximately 40 miles southeast of Tonopah, Nevada. The CAU 414 site consists of the release of radionuclides to the surface and shallow subsurface from the conduct of the Clean Slate III (CSIII) storage–transportation test conducted on June 9, 1963. CAU 414 includes one corrective action site (CAS), TA-23-03CS (Pu Contaminated Soil). The known releases at CAU 414 are the result of the atmospheric dispersal of contamination from the 1963 CSIII test. The CSIII test was a nonnuclearmore » detonation of a nuclear device located inside a reinforced concrete bunker covered with 8 feet of soil. This test dispersed radionuclides, primarily uranium and plutonium, on the ground surface. The presence and nature of contamination at CAU 414 will be evaluated based on information collected from a corrective action investigation (CAI). The investigation is based on the data quality objectives (DQOs) developed on June 7, 2016, by representatives of the Nevada Division of Environmental Protection; the U.S. Air Force; and the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office. The DQO process was used to identify and define the type, amount, and quality of data needed to develop and evaluate appropriate corrective action alternatives for CAU 414.« less
Construction of a Full-size Component of the ICRH System
NASA Astrophysics Data System (ADS)
Mantovani, S.; Sassi, M.; Coppi, B.
2012-10-01
The ICRH system is an important component of the Ignitor project and all efforts have been made to ensure that its design takes into account the construction experience gained in the most advanced laboratories. The system is designed to operate over a frequency range 80-120 MHz, which is consistent with the use of magnetic fields in the range 9-13 T. The maximum delivered power ranges from 8 MW (at 80 MHz) to 6 MW (at 120 MHz) distributed over 4 ports. Since the transition from a detailed design to the actual construction is not without surprises we have constructed a full size prototype of the VTL between the port flange and the antenna straps, with the external support and precise guiding system. The innovative quick latching system located at the end of the coaxial cable was successfully tested, providing perfect interference with the spring Be-Cu electrical contacts. Special care was given to the finishing of the inox surfaces, and to the TIG welds. Vacuum levels of 10-6, compatible with the limit of material degassing, and electrical tests up to 12 kV without discharges have been obtained. A revision of the other key components of the Ignitor machine has been undertaken, taking into account the experience gained in the fabrication of the corresponding prototypes.
Validation of the Mayo Hip Score: construct validity, reliability and responsiveness to change.
Singh, Jasvinder A; Schleck, Cathy; Harmsen, W Scott; Lewallen, David G
2016-01-19
Previous studies have provided the initial evidence for construct validity and test-retest reliability of the Mayo Hip Score. Instruments used for Total Hip Arthroplasty (THA) outcomes assessment should be valid, reliable and responsive to change. Our main objective was to examine the responsiveness to change, association with subsequent revision and the construct validity of the Mayo hip score. Discriminant ability was assessed by calculating effect size (ES), standardized response mean (SRM) and Guyatt's responsiveness index (GRI). Minimal clinically important difference (MCII) and moderate improvement thresholds were calculated. We assessed construct validity by examining association of scores with preoperative patient characteristics and correlation with Harris hip score, and assessed association of scores with the risk of subsequent revision. Five thousand three hundred seven provided baseline data; of those with baseline data, 2,278 and 2,089 (39%) provided 2- and 5-year data, respectively. Large ES, SRM and GRI ranging 2.66-2.78, 2.42-2.61 and 1.67-1.88 were noted for Mayo hip scores with THA, respectively. The MCII and moderate improvement thresholds were 22.4-22.7 and 39.4-40.5 respectively. Hazard ratios of revision surgery were higher with lower final score or less improvement in Mayo hip score at 2-years and borderline significant/non-significant at 5-years, respectively: (1) score ≤55 with hazard ratios of 2.24 (95% CI, 1.45, 3.46; p = 0.0003) and 1.70 (95% CI, 1.00, 2.92; p = 0.05) of implant revision subsequently, compared to 72-80 points; (2) no improvement or worsening score with hazard ratios 3.94 (95% CI, 1.50, 10.30; p = 0.005) and 2.72 (95% CI, 0.85,8.70; p = 0.09), compared to improvement >50-points. Mayo hip score had significant positive correlation with younger age, male gender, lower BMI, lower ASA class and lower Deyo-Charlson index (p ≤ 0.003 for each) and with Harris hip scores (p < 0.001). Mayo Hip Score is valid, sensitive to change and associated with future risk of revision surgery in patients with primary THA.
Otterman, Nicoline; Veerbeek, Janne; Schiemanck, Sven; van der Wees, Philip; Nollet, Frans; Kwakkel, Gert
2017-07-01
To select relevant and feasible instruments for the revision of the Dutch clinical practice guideline for physical therapy in patients with stroke. In this implementation study a comprehensive proposal for ICF categories and matching instruments was developed, based on reliability and validity. Relevant instruments were then selected in a consensus round by 11 knowledge brokers who were responsible for the implementation of the selected instruments. The feasibility of the selected instruments was tested by 36 physical therapists at different work settings within stroke services. Finally, instruments that were deemed relevant and feasible were included in the revised guideline. A total of 28 instruments were recommended for inclusion in the revised guideline. Nineteen instruments were retained from the previous guideline. Ten new instruments were tested in clinical practice, seven of which were found feasible. Two more instruments were added after critical appraisal of the set of the measurement instruments. The revised guideline contains 28 relevant and feasible instrument selected and tested in clinical practice by physical therapists. Further education and implementation is needed to integrate instruments in clinical practice. Further research is proposed for developing and implementing a core set of measurement instruments to be used at fixed time points to establish data registries that allow for continuous improvement of rehabilitation for stroke patients. Implications for Rehabilitation The revised Dutch Stroke Physical Therapy Guideline recommends a total of 28 instruments, that are relevant and feasible for clinical practice of physical therapist in the different settings of stroke rehabilitation. The selection of instrument in daily practice should be part of the clinical reasoning process of PTs and be tailored to individual patients' needs and the degree of priority of the affected ICF category. Suggested education strategies for further integration of instruments in of the daily practice of PTs in Stroke Rehabilitation are: 'Training on the job' and 'peer assessment in clinical situations'.
Haddad, Mark; Menchetti, Marco; McKeown, Eamonn; Tylee, André; Mann, Anthony
2015-02-05
Depression is a common mental disorder associated with substantial disability. It is inadequately recognised and managed, and clinicians' attitudes to this condition and its treatment may play a part in this. Most research in this area has used the Depression Attitude Questionnaire (DAQ), but analyses have shown this measure to exhibit problems in psychometric properties and suitability for the health professionals and settings where depression recognition may occur. We revised the DAQ using a pooled review of findings from studies using this measure, together with a Delphi study which sought the opinions of a panel of relevant experts based in the UK, USA, Australia, and European countries (n = 24) using 3 rounds of questioning to consider attitude dimensions, content, and item wording. After item generation, revision and consensus (agreement >70%) using the Delphi panel, the revised DAQ (R-DAQ) was tested with 1193 health care providers to determine its psychometric properties. Finally the test-retest reliability of the R-DAQ was examined with 38 participants. The 22-item R-DAQ scale showed good internal consistency: Cronbach's alpha coefficient was 0.84; and satisfactory test-retest reliability: intraclass correlation coefficient was 0.62 (95% C.I. 0.37 to 0.78). Exploratory factor analysis favoured a three-factor structure (professional confidence, therapeutic optimism/pessimism, and a generalist perspective), which accounted for 45.3% of the variance. The R-DAQ provides a revised tool for examining clinicians' views and understanding of depression. It addresses important weaknesses in the original measure whilst retaining items and dimensions that appeared valid. This revised scale is likely to be useful in examining attitudes across the health professional workforce and beyond the confines of the UK, and may be valuable for the purpose of evaluating training that aims to address clinicians' attitudes to depression. It incorporates key dimensions of attitudes with a modest number of items making it applicable to use in busy clinical settings.
Does adding antibiotics to cement reduce the need for early revision in total knee arthroplasty?
Bohm, Eric; Zhu, Naisu; Gu, Jing; de Guia, Nicole; Linton, Cassandra; Anderson, Tammy; Paton, David; Dunbar, Michael
2014-01-01
There is considerable debate about whether antibiotic-loaded bone cement should be used for fixation of TKAs. While antibiotics offer the theoretical benefit of lowering early revision due to infection, they may weaken the cement and thus increase the likelihood of aseptic loosening, perhaps resulting in a higher revision rate. We (1) compared the frequency of early knee revision arthroplasty in patients treated with antibiotic-loaded or non-antibiotic-loaded cement for initial fixation, (2) determined effects of age, sex, comorbidities, and surgeons' antibiotic-loaded cement usage patterns on revision rate, and (3) compared causes of revision (aseptic or septic) between groups. Our study sample was taken from the Canadian Joint Replacement Registry and Canada's Hospital Morbidity Database and included cemented TKAs performed between April 1, 2003, and March 31, 2008, including 20,016 TKAs inserted with non-antibiotic-loaded cement and 16,665 inserted with antibiotic-loaded cement. Chi-square test was used to compare the frequency of early revisions between groups. Cox regression modeling was used to determine whether revision rate would change by age, sex, comorbidities, or use of antibiotic-loaded cement. Similar Cox regression modeling was used to compare cause of revision between groups. Two-year revision rates were similar between the groups treated with non-antibiotic-loaded cement and antibiotic-loaded cement (1.40% versus 1.51%, p = 0.41). When controlling for age, sex, comorbidities, diabetes, and surgeons' antibiotic-loaded cement usage patterns, the revision risk likewise was similar between groups. Revision rates for infection were similar between groups; however, there were more revisions for aseptic loosening in the group treated with non-antibiotic-loaded cement (p = 0.02). The use of antibiotic-loaded cement in TKAs performed for osteoarthritis has no clinically significant effect on reducing revision within 2 years in patients who received perioperative antibiotics. Longer followup and confirmation of these findings with other national registries are warranted.
Intermediate load modules for test and evaluation
NASA Technical Reports Server (NTRS)
1984-01-01
Photovoltaic modules were tested for qualification. Tests involved the following: (1) delivery of 20 solar cells for use as reference cells; (2) module documentation and inspection plans specifying the 10 Group I modules; (3) design review of module documentation from Group I modules; (4) revise module documentation to overcome any problems of deficiencies associated with the Group I modules; (5) delivery of 10 Group II modules built to revised specifications; (6) testing of Group II modules to the criteria as outlined in qualification specification. It is found that the solarvolt MSP43E40B satisfies the design criteria of qualification specification for intermediate load modules. Design changes were made in the Group I modules to overcome the deficiencies which allowed Group II modules to pass the qualification tests.
Dorchin, Netta; Astrin, Jonas J.; Bodner, Levona; Harris, Keith M.
2015-01-01
The Palaearctic gall-midge genus Ozirhincus is unique among the Cecidomyiidae for its morphology and biology. Unlike most other phytophagous gall midges, species in this genus do not induce galls but develop inside achenes of Asteraceae plants. The heads of adults are characterized by an unusually elongate proboscis, the function of which is unclear. Despite a lot of attention from taxonomists in the 19th and early 20th century, a proper revision of the genus has been hindered by complex host associations, the loss of most relevant type material, and the lack of a thorough comparative study of all life stages. The present revision integrated morphological, molecular, and life-history data to clearly define species boundaries within Ozirhincus, and delimit host-plant ranges for each of them. A phylogenetic analysis based on the mitochondrial COI and 16S genes confirmed the validity of four distinct species but did not resolve the relationships among them. All species are oligophages, and some may occur together on the same host plant. Species with wider host-plant ranges have wider European and circum-Mediterranean distribution ranges, whereas species with narrower host ranges are limited to Europe and the Russian Far East. As part of the present work, O. hungaricus is reinstated from synonymy, O. tanaceti is synonymized under O. longicollis, neotypes are designated for O. longicollis and O. millefolii, and a lectotype is designated for O. anthemidis. PMID:26134526
Issa, Kimona; Pierce, Todd P; Brothers, Alexander; McInerney, Vincent K; Chughtai, Morad; Mistry, Jaydev B; Bryant, Wayne W; Delanois, Ronald E; Harwin, Steven F; Mont, Michael A
2016-04-01
Manipulation under anesthesia (MUA) can help post-total knee arthroplasty (TKA) patients who have knee stiffness regain range-of-motion. However, despite undergoing MUA, patients may have persistent knee stiffness. Often, this persistent knee stiffness is treated with a repeat MUA. Therefore, the purpose of this study was to evaluate repeat MUAs by assessing: (1) demographic characteristics, (2) range-of-motion, (3) clinical outcomes, and (4) rate of revision surgery in post-TKA patients with persistent knee stiffness who either underwent a single MUA or repeat MUAs. One-hundred-and-sixty-seven post-TKA who had undergone an MUA between 2005 and 2011 at two institutions were reviewed. Patients were stratified into those who had a single-MUA (138 knees) and those who had a repeat MUA (29 knees). The mean follow-up period was 63 months (range, 36 to 90 months). The incidence of repeat MUA within this cohort was determined. Demographics and ROM were compared using Student t-test and Chi-square as appropriate. Functional outcomes were assessed using Knee Society scores (KSS) and compared between the two cohorts. Among the 167 patients who underwent a MUA, 29 (17%) required repeat manipulations. The repeat MUA cohort was younger and more likely to have osteonecrosis as the underlying cause of knee disease. For the repeat MUA cohort, 17 patients (59%) had achieved satisfactory mean gains in ROM after their repeat MUAs. These patients had also achieved excellent mean Knee Society objective and functional scores. However, another seven knees (24%) had further persistent knee stiffness requiring arthrolysis of adhesions and five patients (17%) had undergone revision of the polyethylene spacer or patellar component to improve range-of-motion. In this study, the majority of patients who had undergone a repeat MUA were able to achieve improvements in flexion range-of-motion and functional outcomes. However, the remaining patients required more invasive procedure to treat persistent knee stiffness. In patients who have persistent knee stiffness after MUAs, a repeat MUA may be helpful to increase range-of-motion and function.
Jia, Lin-Zhi; Ya-Jun, Ma; Cao, Yi; Qian, Fen; Li, Xiang-Yu
2012-04-30
The quality index among "Medical Parasitology" exam papers and measured data for students in three majors from the university in 2010 were compared and analyzed. The exam papers were formed from the test item bank. The alpha reliability coefficients of the three exam papers were above 0.70. The knowledge structure and capacity structure of the exam papers were basically balanced. But the alpha reliability coefficients of the second major was the lowest, mainly due to quality of test items in the exam paper and the failure of revising the index of test item bank in time. This observation demonstrated that revising the test items and their index in the item bank according to the measured data can improve the quality of test item bank proposition and reduce the difference among exam papers.
Punt, Ilona M.; Austen, Shennah; Cleutjens, Jack P.M.; Kurtz, Steven M.; ten Broeke, René H.M.; van Rhijn, Lodewijk W.; Willems, Paul C.; van Ooij, André
2011-01-01
Study design Comparative study. Objective To compare periprosthetic tissue reactions observed after total disc replacement (TDR), total hip arthroplasty (THA) and total knee arthroplasty (TKA) revision surgery. Summary of background data Prosthetic wear debris leading to particle disease, followed by osteolysis, is often observed after THA and TKA. Although the presence of polyethylene (PE) particles and periprosthetic inflammation after TDR has been proven recently, osteolysis is rarely observed. The clinical relevance of PE wear debris in the spine remains poorly understood. Methods Number, size and shape of PE particles, as well as quantity and type of inflammatory cells in periprosthetic tissue retrieved during Charité TDR (n=22), THA (n=10) and TKA (n=4) revision surgery were compared. Tissue samples were stained with hematoxylin/eosin and examined by using light microscopy with bright field and polarized light. Results After THA, large numbers of PE particles <6 µm were observed, which were mainly phagocytosed by macrophages. The TKA group had a broad size range with many larger PE particles and more giant cells. In TDR, the size range was similar to that observed in TKA. However, the smallest particles were the most prevalent with 75% of the particles being <6 µm, as seen in revision THA. In TDR, both macrophages and giant cells were present with a higher number of macrophages. Conclusions Both small and large PE particles are present after TDR revision surgery compatible with both THA and TKA wear patterns. The similarities between periprosthetic tissue reactions in the different groups may give more insight in the clinical relevance of PE particles and inflammatory cells in the lumbar spine. The current findings may help to improve TDR design as applied from technologies previously developed in THA and TKA with the goal of a longer survival of TDR. PMID:21336235
Midterm Clinical and Radiographic Results of Mobile-Bearing Revision Total Knee Arthroplasty.
Kim, Raymond H; Martin, J Ryan; Dennis, Douglas A; Yang, Charlie C; Jennings, Jason M; Lee, Gwo-Chin
2017-06-01
Constrained implants are frequently required in revision total knee arthroplasty (TKA) and are associated with an increase in aseptic component loosening and damage or wear to the constraining mechanisms, compared with primary TKA. The purpose of the following study was to evaluate the midterm clinical and radiographic results including the incidence of bearing complications in a group of patients undergoing revision TKA using mobile-bearing revision TKA implants. We retrospectively reviewed 316 consecutive mobile-bearing revision TKAs performed at 2 centers between 2006 and 2010. There were 183 women and 133 men with a mean age of 66 years. The patients were evaluated clinically using the Knee Society scores. A radiographic analysis was performed. Bearing specific complications (ie, instability or dislocation) were recorded. Patients were followed-up for a minimum of 24 months and a median of 59.88 months (range 24-121.2). The average Knee Society knee score and function scores increased from 40.8 and 47.9 points preoperatively to 80 points and 70.3 points, respectively (P < .01). The average knee flexion improved from 105.6° preoperatively to 117.4° postoperatively (P < .01). Eight patients required subsequent implant revision. No cases of bearing complications were observed. Revision TKA using mobile-bearing revision components demonstrated favorable midterm clinical and radiographic results with no occurrence of bearing instability or dislocation. Longer follow-up is required to evaluate for potential advantages of mobile-bearings over fixed-bearing revision components in terms of polyethylene wear reduction, reduced stress transmission across fixation interfaces, and reduced stress on the polyethylene post. Copyright © 2017 Elsevier Inc. All rights reserved.
Evidence-Based School Behavior Assessment of Externalizing Behavior in Young Children
Bagner, Daniel M.; Boggs, Stephen R.; Eyberg, Sheila M.
2011-01-01
This study examined the psychometric properties of the Revised Edition of the School Observation Coding System (REDSOCS). Participants were 68 children ages 3 to 6 who completed parent-child interaction therapy for Oppositional Defiant Disorder as part of a larger efficacy trial. Interobserver reliability on REDSOCS categories was moderate to high, with percent agreement ranging from 47% to 90% (M = 67%) and Cohen’s kappa coefficients ranging from .69 to .95 (M = .82). Convergent validity of the REDSOCS categories was supported by significant correlations with the Intensity Scale of the Sutter-Eyberg Student Behavior Inventory-Revised and related subscales of the Conners’ Teacher Rating Scale-Revised: Long Version (CTRS-R: L). Divergent validity was indicated by nonsignificant correlations between REDSOCS categories and scales on the CTRS-R: L expected not to relate to disruptive classroom behavior. Treatment sensitivity was demonstrated for two of the three primary REDSOCS categories by significant pre to posttreatment changes. This study provides psychometric support for the designation of REDSOCS as an evidence-based assessment procedure for young children. PMID:21687781
Phylogeny and biogeography of Maclura (Moraceae) and the origin of an anachronistic fruit.
Gardner, Elliot M; Sarraf, Paya; Williams, Evelyn W; Zerega, Nyree J C
2017-12-01
Maclura (ca. 12spp., Moraceae) is a widespread genus of trees and woody climbers found on five continents. Maclura pomifera, the Osage orange, is considered a classic example of an anachronistic fruit. Native to the central USA, the grapefruit-sized Osage oranges are unpalatable and have no known extant native dispersers, leading to speculation that the fruits were adapted to extinct megafauna. Our aim was to reconstruct the phylogeny, estimate divergence dates, and infer ancestral ranges of Maclura in order to test the monophyly of subgeneric classifications and to understand evolution and dispersal patterns in this globally distributed group. Employing Bayesian and maximum-likelihood methods, we reconstructed the Maclura phylogeny using two nuclear and five chloroplast loci from all Maclura species and outgroups representing all Moraceae tribes. We reconstructed ancestral ranges and syncarp sizes using a family level dated tree, and used Ornstein-Uhlenbeck models to test for significant changes in syncarp size in the Osage orange lineage. Our analyses support a monophyletic Maclura with a Paleocene crown. Subgeneric sections were monophyletic except for the geographically-disjunct Cardiogyne. There was strong support for current species delineations except in the widespread M. cochinchinensis. South America was reconstructed as the ancestral range for Maclura with subsequent colonization of Africa and the northern hemisphere. The clade containing M. pomifera likely diverged in the Oligocene, closely coinciding with crown divergence dates of the mammoth/mastodon and sloth clades that contain possible extinct dispersers. The best fitting model for syncarp size evolution indicated an increase in both syncarp size and the rate of syncarp size evolution in the Osage orange lineage. We conclude that our findings are consistent with the hypothesis that M. pomifera was adapted to dispersal by extinct megafauna. In addition, we consider dispersal rather than vicariance to be most likely responsible for the present distribution of Maclura, as crown divergence post-dated the separation of Africa and South America. We propose revised sectional delimitations based on the phylogeny. This study represents a complete phylogenetic and biogeographic analysis of this globally distributed genus and provides a basis for future work, including a taxonomic revision. Copyright © 2017. Published by Elsevier Inc.
Shawahna, Ramzi; Hroub, Abdel Kareem; Abed, Eliama; Jibali, Sondos; Al-Saghir, Ruba; Zaid, Abdel Naser
2016-01-01
Atorvastatin reduces morbidity and mortality due to cardiovascular events. This study was conducted to assess the prices and pharmaceutical quality of innovator atorvastatin 20 mg with its locally available generics in Palestine and to assess the suitability of their interchangeability. The prices of innovator and generic atorvastatin 20 mg were determined and compared. Innovator atorvastatin and four generic products were tested for their pharmaceutical quality. Tablets were tested for their drug contents, weight uniformity, hardness, disintegration and dissolution. Three out of four generics were less expensive than the innovator. Pharmaceutical quality assessments were satisfactory and within limits for all atorvastatin tested products. The average weight ranged from 206.6 ± 8.40 to 330 ± 3.92 mg and the %RSDs were within the permitted limits as per USP. Tablet hardness ranged from 102 ± 1.41 to 197.4 ± 6.88 kg and drug contents ranged from 92.2% to 105.3%. All products disintegrated within permitted time limits and showed very rapid dissolution. Products released more than 85% of their drug contents in less than 15 min. Our results showed that all tested innovator and generic atorvastatin products were of good pharmaceutical quality. Despite the lack of in vivo evaluation, our results indicate that these products are equivalent in vitro. Considering the in vitro release characteristics, these products might be used interchangeably. However, regulatory authorities permit the use of in vitro data in establishing similarity between immediate release oral dosage forms containing biopharmaceutical classification system class I and III drugs only.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haynam, C A; Sacks, R A; Moses, E I
We appreciate Stephen Bodner's continuing interest in the performance of the NIF laser system. However, we find it necessary to disagree with the conclusions he reached in his comments [Appl. Opt. 47, XXX (2008)] on 'National Ignition Facility Laser Performance Status' [Appl. Opt. 46, 3276 (2007)]. In fact, repeated and ongoing tests of the NIF beamlines have demonstrated that NIF can be expected not only to meet or exceed its requirements as established in the mid-1990s in the document National Ignition Facility Functional Requirements and Primary Criteria [Revision 1.3, Report NIF-LLNL-93-058 (1994)], but also to have the flexibility that providesmore » for successfully meeting an ever expanding range of mission goals, including those of ignition.« less
NASA Astrophysics Data System (ADS)
Ballabio, G.; Dipierro, G.; Veronesi, B.; Lodato, G.; Hutchison, M.; Laibe, G.; Price, D. J.
2018-06-01
We describe a new implementation of the one-fluid method in the SPH code PHANTOM to simulate the dynamics of dust grains in gas protoplanetary discs. We revise and extend previously developed algorithms by computing the evolution of a new fluid quantity that produces a more accurate and numerically controlled evolution of the dust dynamics. Moreover, by limiting the stopping time of uncoupled grains that violate the assumptions of the terminal velocity approximation, we avoid fatal numerical errors in mass conservation. We test and validate our new algorithm by running 3D SPH simulations of a large range of disc models with tightly and marginally coupled grains.
Morris, John C.
2012-01-01
Objective To evaluate the potential impact of revised criteria for mild cognitive impairment (MCI), developed by a Workgroup sponsored by the National Institute on Aging and the Alzheimer’s Association, on the diagnosis of very mild and mild Alzheimer disease (AD) dementia. Design Retrospective review of ratings of functional impairment across diagnostic categories. Participants: The functional ratings of individuals (N = 17,535) with normal cognition, MCI, or AD dementia who were evaluated at Alzheimer’s Disease Centers and submitted to the National Alzheimer’s Coordinating Center were assessed in accordance with the definition of “functional independence” allowed by the revised criteria. Methods Pairwise demographic differences between the 3 diagnostic groups were tested using t-tests for continuous variables and chi-square for categorical variables. Results Almost all (99.8%) of individuals currently diagnosed with very mild AD dementia and the large majority (92.7%) of those diagnosed with mild AD dementia could be reclassified as MCI with the revised criteria, based on their level of impairment in the Clinical Dementia Rating domains for performance of instrumental activities of daily living in the community and at home. Large percentages of these AD dementia individuals also meet the revised “functional independence” criterion for MCI as measured by the Functional Assessment Questionnaire. Conclusions The categorical distinction between MCI and milder stages of Alzheimer dementia has been compromised by the revised criteria. The resulting diagnostic overlap supports the premise that “MCI due to AD” represents the earliest symptomatic stage of AD. PMID:22312163
Morris, John C
2012-06-01
To evaluate the potential impact of revised criteria for mild cognitive impairment (MCI), developed by a work group sponsored by the National Institute on Aging and the Alzheimer's Association, on the diagnosis of very mild and mild Alzheimer disease (AD)dementia. Retrospective review of ratings of functional impairment across diagnostic categories. Alzheimer's Disease Centers and the National Alzheimer's Coordinating Center. Individuals (N=17 535) with normal cognition,MCI, or AD dementia. The functional ratings of individuals with normal cognition, MCI, or AD dementia who were evaluated at Alzheimer's Disease Centers and submitted to the National Alzheimer's Coordinating Center were assessed in accordance with the definition of "functional independence" allowed by the revised criteria. Pairwise demographic differences between the 3 diagnostic groups were tested using t tests for continuous variables and 2 for categorical variables. Almost all (99.8%) individuals currently diagnosed with very mild AD dementia and the large majority(92.7%) of those diagnosed with mild AD dementia could be reclassified as having MCI with the revised criteria,based on their level of impairment in the Clinical Dementia Rating domains for performance of instrumental activities of daily living in the community and at home.Large percentages of these individuals with AD dementia also meet the revised "functional independence" criterion for MCI as measured by the Functional Assessment Questionnaire. The categorical distinction between MCI and milder stages of AD dementia has been compromised by the revised criteria. The resulting diagnostic overlap supports the premise that "MCI due to AD" represents the earliest symptomatic stage of AD.
Houwink, Annemieke; Geerdink, Yvonne A; Steenbergen, Bert; Geurts, Alexander C H; Aarts, Pauline B M
2013-01-01
To investigate the validity and reliability of the revised Video-Observation Aarts and Aarts module: Determine Developmental Disregard (VOAA-DDD-R). Upper-limb capacity and performance were assessed in children with unilateral spastic cerebral palsy (CP) by measuring overall duration of affected upper-limb use and the frequency of specific behaviours during a task in which bimanual activity was demanded ('stringing beads') and stimulated ('decorating a muffin'). Developmental disregard was defined as the difference in duration of affected upper-limb use between both tasks. Raters were two occupational and one physical therapist who received 3 hours of training. Construct validity was determined by comparing children with CP with typically developing children. Intrarater, interrater, and test-retest reliability were determined using the intraclass correlation coefficient. Standard errors of measurement and smallest detectable differences were also calculated. Twenty-five children with CP (15 females, 10 males; mean age 4 y 9 mo [SD 1 y 7 mo], range 2 y 9 mo-8 y; Manual Ability Classification System levels I-III) scored lower on capacity (p=0.052) and performance (p<0.001), and higher on developmental disregard (p<0.001) than 46 age- and sex-matched typically developing children (23 males; mean age 5 y 3 mo [SD 1 y 5 mo], range 2 y 6 mo-8 y). The intraclass correlation coefficients (0.79-1.00) indicated good reliability. Absolute agreement was high, standard errors of measurement ranged from 4.5 to 6.8%, and smallest detectable differences ranged from 12.5 to 19.0%. The VOAA-DDD-R can be reliably and validly used by occupational and physical therapists to assess upper-limb capacity, performance, and developmental disregard in children (2 y 6 mo-8 y) with CP. © The Authors. Developmental Medicine & Child Neurology © 2012 Mac Keith Press.
The Instinct Fallacy: The Metacognition of Answering and Revising during College Exams
ERIC Educational Resources Information Center
Couchman, Justin J.; Miller, Noelle E.; Zmuda, Shaun J.; Feather, Kathryn; Schwartzmeyer, Tina
2016-01-01
Students often gauge their performance before and after an exam, usually in the form of rough grade estimates or general feelings. Are these estimates accurate? Should they form the basis for decisions about study time, test-taking strategies, revisions, subject mastery, or even general competence? In two studies, undergraduates took a real…
ERIC Educational Resources Information Center
Smith, Kenneth H.
2011-01-01
The Inviting School Survey-Revised (ISS-R) was adapted and translated into Traditional Chinese (ISS-RC), using a five-step process, based on international test administration guidelines, involving judgmental, logical, and empirical methods. Both versions were administered to a convenience sample of Chinese-English fluent Hong Kong school community…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-22
... 2280 amends the Arizona Revised Statutes (ARS) section 49-542 (``Emissions inspection program; powers... motorcycles from the VEI emissions testing requirement. \\2\\ The changes to ARS Section 49-542 are self... appendix A of the 2009 VEI SIP Revision with a certified copy of the codified version of ARS section 49-542...
B.G. Marcot; J.D. Steventon; G.D. Sutherland; R.K. McCann
2006-01-01
We provide practical guidelines for developing, testing, and revising Bayesian belief networks (BBNs). Primary steps in this process include creating influence diagrams of the hypothesized "causal web" of key factors affecting a species or ecological outcome of interest; developing a first, alpha-level BBN model from the influence diagram; revising the model...
ERIC Educational Resources Information Center
Lindwall, Magnus; Palmeira, Antonio
2009-01-01
The present study investigated the factorial validity and factorial invariance of the 21-item Exercise Dependence Scale-Revised using 162 Swedish and 269 Portuguese exercisers. In addition, the prevalence of exercise dependence symptoms and links to exercise behavior, gender, and age in the two samples was also studied. Confirmatory factor…
ERIC Educational Resources Information Center
Yang, Hongfei; Hong, Chaoqin; Tao, Xiaodan; Zhu, Lingyi
2015-01-01
This study examined the structure, reliability, and validity of the revised Chinese version of the Child and Adolescent Perfectionism Scale (N = 933). The results confirmed the four-factor structure of the Chinese version of the Child and Adolescent Perfectionism Scale. Implications, limitations, and suggestions for future research are provided.
ERIC Educational Resources Information Center
Aryadoust, Vahid; Akbarzadeh, Sanaz; Akbarzedeh, Sara
2011-01-01
The Multidimensional School Anger Inventory-Revised (MSAI-R) is a measurement tool to evaluate high school students' anger. Its psychometric features have been tested in the USA, Australia, Japan, Guatemala, and Italy. This study investigates the factor structure and psychometric quality of the Persian version of the MSAI-R using data from an…
ERIC Educational Resources Information Center
Florida State Dept. of Education, Tallahassee. Bureau of Instructional Support and Community Services.
The 1999 Florida Legislature revised the laws pertaining to the assessment of students in Department of Juvenile Justice (DJJ) facilities. Revisions identified specific requirements for measuring student academic progress in the basic skill areas of reading, writing, and mathematics. Following the passage of this legislation, the Department of…
ERIC Educational Resources Information Center
Wilson, Steven R.; Aleman, Carlos G.; Leatham, Geoff B.
1998-01-01
Challenges and revises politeness theory by analyzing potential implications for both parties' face when the logical preconditions for seeking compliance are framed by specific influence goals. Tests undergraduate students' imagining asking favors, giving advice, and enforcing obligations with same-sex friends. Finds perceived face threats varied…
Dragesund, Tove; Strand, Liv Inger; Grotle, Margreth
2018-02-01
The Body Awareness Rating Questionnaire (BARQ) is a self-report questionnaire aimed at capturing how people with long-lasting musculoskeletal pain reflect on their own body awareness. Methods based on classical test theory were applied to the development of the instrument and resulted in 4 subscales. However, the scales were not correlated, and construct validity might be questioned. The primary purpose of this study was to explore the possibility of developing a unidimensional scale from items initially collected for the BARQ using Rasch analysis. A secondary purpose was to investigate the test-retest reliability of a revised version of the BARQ. This was a methodological study. Rasch and reliability analyses were performed for 3 samples of participants with long-lasting musculoskeletal pain. The first Rasch analysis was carried out on 66 items generated for the original BARQ and scored by 300 participants. The items supported by the first analysis were scored by a new group of 127 participants and analyzed in a second Rasch analysis. For the test-retest reliability analysis, 48 participants scored the revised BARQ items twice within 1 week. The 2-step Rasch analysis resulted in a unidimensional 12-item revised version of the BARQ with a 4-point response scale (scores from 0 to 36). It showed a good fit to the Rasch model, with acceptable internal consistency, satisfactory fit residuals, and no disordered thresholds. Test-retest reliability was high, with an intraclass correlation coefficient of .83 (95% CI = .71-.89) and a smallest detectable change of 6.3 points. The small sample size in the second Rasch analysis was a study limitation. The revised BARQ is a unidimensional and feasible measurement of body awareness, recommended for use in the context of body-mind physical therapy approaches for musculoskeletal conditions. © 2017 American Physical Therapy Association
Corbel, Michael J; Das, Rose Gaines; Lei, Dianliang; Xing, Dorothy K L; Horiuchi, Yoshinobu; Dobbelaer, Roland
2008-04-07
This report reflects the discussion and conclusions of a WHO group of experts from National Regulatory Authorities (NRAs), National Control Laboratories (NCLs), vaccine industries and other relevant institutions involved in standardization and control of diphtheria, tetanus and pertussis vaccines (DTP), held on 20-21 July 2006 and 28-30 March 2007, in Geneva Switzerland for the revision of WHO Manual for quality control of DTP vaccines. Taking into account recent developments and standardization in quality control methods and the revision of WHO recommendations for D, T, P vaccines, and a need for updating the manual has been recognized. In these two meetings the current situation of quality control methods in terms of potency, safety and identity tests for DTP vaccines and statistical analysis of data were reviewed. Based on the WHO recommendations and recent validation of testing methods, the content of current manual were reviewed and discussed. The group agreed that the principles to be observed in selecting methods included identifying those critical for assuring safety, efficacy and quality and which were consistent with WHO recommendations/requirements. Methods that were well recognized but not yet included in current Recommendations should be taken into account. These would include in vivo and/or in vitro methods for determining potency, safety testing and identity. The statistical analysis of the data should be revised and updated. It was noted that the mouse based assays for toxoid potency were still quite widely used and it was desirable to establish appropriate standards for these to enable the results to be related to the standard guinea pig assays. The working group was met again to review the first drafts and to input further suggestions or amendments to the contributions of the drafting groups. The revised manual was to be finalized and published by WHO.
Psychometric properties of Conversion Disorder Scale- Revised (CDS) for children.
Ijaz, Tazvin; Nasir, Attikah; Sarfraz, Naema; Ijaz, Shirmeen
2017-05-01
To revise conversion disorder scale and to establish the psychometric properties of the revised scale. This case-control study was conducted from February to June, 2014, at the Government College University, Lahore, Pakistan, and comprised schoolchildren and children with conversion disorder. In order to generate items for revised version of conversion disorder scale, seven practising mental health professionals were consulted. A list of 42 items was finalised for expert ratings. After empirical validation, a scale of 40 items was administered on the participants and factor analysis was conducted. Of the240 participants, 120(50%) were schoolchildren (controls group) and 120(50%)were children with conversion disorder (clinical group).The results of factor analysis revealed five factors (swallowing and speech symptoms, motor symptoms, sensory symptoms, weakness and fatigue, and mixed symptoms) and retention of all 40 items of revised version of conversion disorder scale. Concurrent validity of the revised scale was found to be 0.81 which was significantly high. Similarly, discriminant validity of the scale was also high as both clinical and control groups had significant difference (p<0.001) in scores. Cronbach's alpha of scale was a=0.91 while item total correlation ranged from 0.50 to 0.80. The sensitivity and specificity analysis indicated that the revised conversion disorder scale was 76% sensitive to predicting conversion disorder while specificity showed that the scale was 73% accurate in specifying participants of the control group. The revised version of conversion disorder scale was a reliable and valid tool to be used for screening of children with conversion disorder.
Survey of Collision Avoidance and Ranging Sensors for Mobile Robots. Revision 1
1992-12-01
diagram of the Hamamatsu’s Range-Finder Chip Set, which applies the principle of triangulation (Hamamatsu Corporation, 1990) ....................... 37...platform (Courtesy Transitions Research Company ) . ............................................ 68 37. The Sensus 300 configured for 360-degree coverage... applied to the detection of metal objects located at short-range. Typical inductive sensors generate an oscillatory radio-frequency (RF) field around a
Patel, Priya; Gabbard, Carl
2017-05-01
While Developmental Coordination Disorder (DCD) has gained worldwide attention, in India it is relatively unknown. The revised DCD Questionnaire (DCDQ'07) is one of the most utilized screening tools for DCD. The aim of this study was to translate the DCDQ'07 into the Hindi language (DCDQ-Hindi) and test its basic psychometric properties. The DCDQ'07 was translated following guidelines for cross cultural adaptation of instruments. Parents of 1100 children (5-15 years) completed the DCDQ-Hindi, of which 955 were considered for data analysis and 60 were retested randomly after 3 weeks for test-retest reliability. The DCDQ-Hindi showed high internal consistency (α = .86) and moderate test-retest reliability (.73). Confirmatory factor analysis showed equivalence to the DCDQ'07. The% probable DCD using DCDQ'07 cutoff scores (≤57) ranged from 22% to 68%. Using more stringent cutoffs (≤36) it ranged from 5% to 9%. Significant difference was seen for gender (p < .05) in subset 1(gross-motor skills) total scores. The DCDQ-Hindi reveals promise for initial identification of Hindi speaking Indian children with DCD. Based on more stringent cut-off scores, the "probable prevalence" of children with risk of DCD in India appears to be around 6-7%. Research with larger sample and comparison with the MABC-2 or equivalent is needed.
Evaluation of Item Candidates: The PROMIS Qualitative Item Review
DeWalt, Darren A.; Rothrock, Nan; Yount, Susan; Stone, Arthur A.
2009-01-01
One of the PROMIS (Patient-Reported Outcome Measurement Information System) network's primary goals is the development of a comprehensive item bank for patient-reported outcomes of chronic diseases. For its first set of item banks, PROMIS chose to focus on pain, fatigue, emotional distress, physical function, and social function. An essential step for the development of an item pool is the identification, evaluation, and revision of extant questionnaire items for the core item pool. In this work, we also describe the systematic process wherein items are classified for subsequent statistical processing by the PROMIS investigators. Six phases of item development are documented: identification of extant items, item classification and selection, item review and revision, focus group input on domain coverage, cognitive interviews with individual items, and final revision before field testing. Identification of items refers to the systematic search for existing items in currently available scales. Expert item review and revision was conducted by trained professionals who reviewed the wording of each item and revised as appropriate for conventions adopted by the PROMIS network. Focus groups were used to confirm domain definitions and to identify new areas of item development for future PROMIS item banks. Cognitive interviews were used to examine individual items. Items successfully screened through this process were sent to field testing and will be subjected to innovative scale construction procedures. PMID:17443114
Zhu, Zhonglin; Ding, Hui; Shao, Hongyi; Zhou, Yixin; Wang, Guangzhi
2013-04-09
The wire fixation and the cable grip fixation have been developed for the extended trochanteric osteotomy (ETO) in the revision of total hip arthroplasty (THA). Many studies reported the postoperative performance of the patients, but with little quantitative biomechanical comparison of the two fixation systems. An in-vitro testing approach was designed to record the loosening between the femoral bed and the greater trochanter after fixations. Ten cadaveric femurs were chosen in this study. Each femur underwent the THA, revision by ETO and fixations. The tension to the greater trochanter was from 0 to 500N in vertical and lateral direction, respectively. The translation and rotation of the greater trochanter with respect to the bony bed were captured by an optical tracking system. In the vertical tension tests, the overall translation of the greater trochanter was observed 0.4 mm in the cable fixations and 7.0 mm in the wire fixations. In the lateral tension tests, the overall motion of the greater trochanter was 2.0 mm and 1.2° in the cable fixations, while it was 6.2 mm and 5.3° in the wire fixations. The result was significantly different between the two fixation systems. The stability of the proximal femur after ETO using different fixations in the revision THA was investigated. The cable grip fixation was significantly more stable than the wire fixation.
Predictors of surgical revision after in situ decompression of the ulnar nerve.
Krogue, Justin D; Aleem, Alexander W; Osei, Daniel A; Goldfarb, Charles A; Calfee, Ryan P
2015-04-01
This study was performed to identify factors associated with the need for revision surgery after in situ decompression of the ulnar nerve for cubital tunnel syndrome. This case-control investigation examined all patients treated at one institution with open in situ decompression for cubital tunnel syndrome between 2006 and 2011. The case patients were 44 failed decompressions that required revision, and the controls were 79 randomly selected patients treated with a single operation. Demographic data and disease-specific data were extracted from the medical records. The rate of revision surgery after in situ decompression was determined from our 5-year experience. A multivariate logistic regression model was used based on univariate testing to determine predictors of revision cubital tunnel surgery. Revision surgery was required in 19% (44 of 231) of all in situ decompressions performed during the study period. Predictors of revision surgery included a history of elbow fracture or dislocation (odds ratio [OR], 7.1) and McGowan stage I disease (OR, 3.2). Concurrent surgery with in situ decompression was protective against revision surgery (OR, 0.19). The rate of revision cubital tunnel surgery after in situ nerve decompression should be weighed against the benefits of a less invasive procedure compared with transposition. When considering in situ ulnar nerve decompression, prior elbow fracture as well as patients requesting surgery for mild clinically graded disease should be viewed as risk factors for revision surgery. Patient factors often considered relevant to surgical outcomes, including age, sex, body mass index, tobacco use, and diabetes status, were not associated with a greater likelihood of revision cubital tunnel surgery. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Bobby, Zachariah; Nandeesha, H; Sridhar, M G; Soundravally, R; Setiya, Sajita; Babu, M Sathish; Niranjan, G
2014-01-01
Graduate medical students often get less opportunity for clarifying their doubts and to reinforce their concepts after lecture classes. The Medical Council of India (MCI) encourages group discussions among students. We evaluated the effect of identifying mistakes in a given set of wrong statements and their correction by a small group discussion by graduate medical students as a revision exercise. At the end of a module, a pre-test consisting of multiple-choice questions (MCQs) was conducted. Later, a set of incorrect statements related to the topic was given to the students and they were asked to identify the mistakes and correct them in a small group discussion. The effects on low, medium and high achievers were evaluated by a post-test and delayed post-tests with the same set of MCQs. The mean post-test marks were significantly higher among all the three groups compared to the pre-test marks. The gain from the small group discussion was equal among low, medium and high achievers. The gain from the exercise was retained among low, medium and high achievers after 15 days. Identification of mistakes in statements and their correction by a small group discussion is an effective, but unconventional revision exercise in biochemistry. Copyright 2014, NMJI.
Evaluation of an adult insulin infusion protocol at an academic medical center.
Petrov, Katerina I; Burns, Tammy L; Drincic, Andjela
2012-05-01
Acknowledging evidence of possible detrimental effects of tightly controlled blood glucose levels, the American Association of Clinical Endocrinologists and the American Diabetes Association published a consensus statement recommending less strict control for most diabetic patients. As a result of these recommendations, our academic center at Creighton University Medical Center revised its adult insulin infusion protocol to target blood glucose levels ranging from 120 to 180 mg/dL for regular (standard) glycemic control and 80 to 120 mg/dL for tight control; previous targets had ranged from 80 to 180 mg/dL and 70 to 110 mg/dL, respectively. The primary objective was to evaluate the time that blood glucose values were within the target range for patients receiving the new protocol, compared with patients receiving the previous protocol. Our study was designed to evaluate the effectiveness and safety of the revised protocol. Using a retrospective chart review, we collected data for 4 months from patients on the old insulin protocol (May to August 2009) and for 4 months from patients on the new protocol (September to December 2009). Secondary endpoints included the number of hypoglycemic episodes (blood glucose below 70 mg/dL) and severe hypoglycemic episodes (blood glucose 40 mg/dL or lower) experienced by patients receiving the new insulin protocol compared with those receiving the former protocol. Patient characteristics were similar at baseline. Blood glucose values stayed within the target range for a significantly shorter time with the new protocol than with the former protocol (44.6% vs. 56.8%, respectively; P < 0.001), probably because of the narrower target range in the revised protocol. No statistically significant differences in hypoglycemia were observed after the protocol was changed. Hypoglycemia occurred in 31% of the former-protocol patients compared with 18% of the revised-protocol patients. Severe hypoglycemia was experienced by 2.1% of patients on the old protocol and by 3.1% of patients on the new protocol. Rates of severe hypoglycemia were low (2.6%) with the original protocol. Patients' blood glucose levels were within the target range for a shorter time with the new protocol. Fewer episodes of hypoglycemia were recorded with the new protocol, but rates of severe hypoglycemia were similar with both protocols.
Ogrinc, Greg; Davies, Louise; Goodman, Daisy; Batalden, Paul; Davidoff, Frank; Stevens, David
2016-02-01
Since the publication of Standards for QUality Improvement Reporting Excellence (SQUIRE 1.0) guidelines in 2008, the science of the field has advanced considerably. In this article, we describe the development of SQUIRE 2.0 and its key components. We undertook the revision between 2012 and 2015 using (1) semistructured interviews and focus groups to evaluate SQUIRE 1.0 plus feedback from an international steering group, (2) two face-to-face consensus meetings to develop interim drafts, and (3) pilot testing with authors and a public comment period. SQUIRE 2.0 emphasizes the reporting of three key components of systematic efforts to improve the quality, value, and safety of health care: the use of formal and informal theory in planning, implementing, and evaluating improvement work; the context in which the work is done; and the study of the intervention(s). SQUIRE 2.0 is intended for reporting the range of methods used to improve health care, recognizing that they can be complex and multidimensional. It provides common ground to share these discoveries in the scholarly literature (www.squire-statement.org). Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
Delanois, Ronald E; Gwam, Chukwuweike U; Mohamed, Nequesha; Khlopas, Anton; Chughtai, Morad; Malkani, Arthur L; Mont, Michael A
2017-09-01
We are reporting on the minimum 5-year outcomes of patients who underwent revision total hip arthroplasty (THA) using a specific highly-porous titanium shell. We assessed (1) aseptic and all-cause survivorship; (2) functional outcomes; (3) complications; and (4) radiographic outcomes. Two hospital databases were evaluated for patients who underwent revision THA due to component instability or aseptic loosening using a cementless highly-porous titanium shell between September 2006 and December 2011. This yielded 35 patients who had a mean age of 61 years (range 14-88 years). Patients had a mean follow-up of 6 years (minimum 5 years). All-cause and aseptic survivorship of the shell was calculated. Functional outcomes were assessed using the Harris Hip Score. We determined the incidence of postoperative complications and performed radiographic evaluation of pelvic radiographs from regular office visits. The aseptic survivorship of the acetabular component was 97% (95% confidence interval; 8.1-9.5). The all-cause survivorship of the acetabular component was 91% (95% confidence interval; 7.3-8.1). One patient had an aseptic failure and 2 patients had septic failures. The mean postoperative Harris Hip Score was 76 points (range, 61-91 points). Excluding the aseptic and septic failures, there was no osteolysis or progressive radiolucencies present on radiographic evaluation at final follow-up. At a minimum of 5-year follow-up, the highly-porous titanium acetabular revision shell has excellent survivorship and functional outcomes. Although long-term follow-up is needed to further monitor these implants, the results are promising and demonstrate that this prosthesis may be an excellent option for patients undergoing revision THA. Copyright © 2017 Elsevier Inc. All rights reserved.
Lewis, Peter L; Gamboa, Ai E; Campbell, David G; Lorimer, Michelle
2017-10-01
Although knee replacements have specifically designed patella prostheses that correspond to the geometry of their femoral components, a patella prosthesis that is unmatched to the femoral component may occasionally be inserted. In revision total knee arthroplasty (TKA), an originally resurfaced patella may be left, but the femoral component revised to one that does not match the patella. Few studies have compared the outcome of matched and unmatched patella components in TKA. This study compared the primary or revision TKA outcome of procedures where patella components matched to their femoral counterparts were inserted, with procedures using patella and femoral components that were unmatched. Data on all primary and revision TKA procedures without a patella component or a matched or an unmatched patella component were obtained from the Australian Orthopaedic Association National Joint Replacement Registry (AOANJRR). Revision surgery was the outcome measure. Cumulative percent revised (CPR) were calculated and Hazard ratios with p values were used to test statistical significance. In primary TKA, there were higher rates of revision where unmatched patella components were used, regardless of implant design. There was no difference in the second revision rates of unmatched versus matched patella component groups. This was evident where delayed resurfacing was carried out, and where the patella prosthesis was left alone but the femoral component was changed. All primary TKA procedures require a patella component corresponding to the femoral component if the patella is resurfaced. Conversely, revision knee arthroplasties are not affected by the use of dissimilar patella and femoral components. Copyright © 2017 Elsevier B.V. All rights reserved.
Revision Hip Arthroscopy: A Systematic Review of Diagnoses, Operative Findings, and Outcomes.
Cvetanovich, Gregory L; Harris, Joshua D; Erickson, Brandon J; Bach, Bernard R; Bush-Joseph, Charles A; Nho, Shane J
2015-07-01
To determine indications for, operative findings of, and outcomes of revision hip arthroscopy. A systematic review was registered with PROSPERO and performed based on PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. Therapeutic clinical outcome studies reporting the indications for, operative findings of, and outcomes of revision hip arthroscopy were eligible for inclusion. All study-, patient-, and hip-specific data were extracted and analyzed. The Modified Coleman Methodology Score was used to assess study quality. Five studies were included (348 revision hip arthroscopies; 333 patients; mean age, 31.4 ± 4.2 years; 60% female patients). All 5 studies were either Level III or IV evidence. The surgeon performing revision hip arthroscopy was the same as the primary hip surgeon in only 25% of cases. The mean time between primary and revision hip arthroscopy was 27.8 ± 7.0 months (range, 2 to 193 months). Residual femoroacetabular impingement was the most common indication for and operative finding of revision hip arthroscopy (81% of cases). The most commonly reported revision procedures were femoral osteochondroplasty (24%) and acetabuloplasty (18%). The modified Harris Hip Score was used in all 5 analyzed studies, with significant (P < .05) improvements observed in all 5 studies (weighted mean, 56.8 ± 3.6 preoperatively v 72.0 ± 8.3 at final follow-up [22.4 ± 9.8 months]; P = .01). Other patient-reported outcomes (Non-Arthritic Hip Score, Hip Outcome Score, 33-item International Hip Outcome Tool, Short Form 12) showed significant improvements but were not used in all 5 analyzed studies. After revision hip arthroscopy, subsequent reported operations were hip arthroplasty in 11 patients and re-revision hip arthroscopy in 8 patients (5% total reoperation rate). Revision hip arthroscopy is most commonly performed for residual femoroacetabular impingement, with statistically significant and clinically relevant improvements shown in multiple patient-reported clinical outcome scores at short-term follow-up. The reoperation rate after revision hip arthroscopy is 5% within 2 years, including further arthroscopy or conversion to hip arthroplasty. Level IV, systematic review of Level III and IV studies. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Dupepe, Esther B; Hopson, Betsy; Johnston, James M; Rozzelle, Curtis J; Jerry Oakes, W; Blount, Jeffrey P; Rocque, Brandon G
2016-11-01
OBJECTIVE It is generally accepted that cerebrospinal fluid shunts fail most frequently in the first years of life. The purpose of this study was to describe the risk of shunt failure for a given patient age in a well-defined cohort with shunted hydrocephalus due to myelomeningocele (MMC). METHODS The authors analyzed data from their institutional spina bifida research database including all patients with MMC and shunted hydrocephalus. For the entire population, the number of shunt revisions in each year of life was determined. Then the number of patients at risk for shunt revision during each year of life was calculated, thus enabling them to calculate the rate of shunt revision per patient in each year of life. In this way, the timing of all shunt revision operations for the entire clinic population and the likelihood of having a shunt revision during each year of life were calculated. RESULTS A total of 655 patients were enrolled in the spina bifida research database, 519 of whom had a diagnosis of MMC and whose mean age was 17.48 ± 11.7 years (median 16 years, range 0-63 years). Four hundred seventeen patients had had a CSF shunt for the treatment of hydrocephalus and thus are included in this analysis. There were 94 shunt revisions in the 1st year of life, which represents a rate of 0.23 revisions per patient in that year. The rate of shunt revision per patient-year initially decreased as age increased, except for an increase in revision frequency in the early teen years. Shunt revisions continued to occur as late as 43 years of age. CONCLUSIONS These data substantiate the idea that shunt revision surgeries in patients with MMC are most common in the 1st year of life and decrease thereafter, except for an increase in the early teen years. A persistent risk of shunt failure was observed well into adult life. These findings underscore the importance of routine follow-up of all MMC patients with shunted hydrocephalus and will aid in counseling patients and families.
Five to thirteen year results of a cemented dual mobility socket to treat recurrent dislocation.
Hamadouche, Moussa; Ropars, Mickael; Rodaix, Camille; Musset, Thierry; Gaucher, François; Biau, David; Courpied, Jean Pierre; Huten, Denis
2017-03-01
Dual mobility (DM) socket has been associated with a low rate of dislocation following both primary and revision total hip arthroplasty (THA). However, little is known about the long-term efficiency of DM in the treatment of THA instability. The purpose of this retrospective study was to evaluate the outcome of a cemented DM socket to treat recurrent dislocation after a minimum of five year follow-up. The series included 51 patients with a mean age of 71.3 ± 11.5 (range, 41-98) years presenting with recurrent dislocation (mean 3.3). A single DM socket design was used consisting of a stainless steel outer shell with grooves with a highly polished inner surface articulating with a mobile polyethylene component. The femoral head was captured in the polyethylene component using a snap-fit type mechanism, the latter acting as a large unconstrained head inside the metal cup. At the minimum five year follow-up evaluation, 18 of the 51 patients deceased at a mean of 4.8 ± 2.3 years, three were lost to follow-up at a mean of 1.4 years, seven had been revised at a mean of 4.7 ± 3.1 years (range, 1.5-9.1), and the remaining 23 were still alive and did not have revision at a mean of 8.2 ± 2.4 years (range, 5-13 years). Of the seven revision, three were performed for further episodes of dislocation (at the large bearing for one patient and intra-prosthetic for two patients) after a mean 5.9 ± 2.9 years (range, 2.7-9.1), whereas two were performed for late sepsis and two for aseptic loosening of the acetabular component. Radiographic analysis did not reveal any further loosening on the acetabular side. The survival rate of the cup at ten years, using re-dislocation as the end-point, was 86.1 ± 8.4% (95% confidence interval, 69.7-100%). The survival rate of the cup at ten years, using revision for any reason as the end-point, was 75.2 ± 9.3% (95% confidence interval, 56.9-93.5%). A cemented dual mobility cup was able to restore hip stability in 94% of patients presenting with recurrent dislocating hips up to 13-year follow-up with none of the complications associated with constrained devices, as mechanical failure occurred in only 3.9% of the patients of this series. The overall reduced survival using revision for any reason as the end-point at ten years was related to this specific patients population that had various co-morbidities.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-28
... subparagraphs ranging from the lowest to the highest operating frequency ranges, with a gap for MMIC power... control high frequency (HF) surface wave radar capable of ``tracking'' surface targets on oceans... surreptitious interception of wire, oral, or electronic communications.'') Paragraph .c would control microwave...
Jolosky, Theo; Watson, Carol
2015-01-01
Theodore Millon was a brilliant man: erudite, thoughtful, confident, deliberate, and curious. He was an integrative thinker. It is widely known how these characteristics manifested themselves in his landmark work in the areas of personality theory, personality development, and personality assessment. What is likely less well known is that he displayed these same characteristics in and to the world of business; in particular, his relationships with those who published and distributed his assessment measures. This article traces those relationships. Various components are explored, ranging from product development to product marketing, from the protection of intellectual property to the development and execution of contracts, from deciding how and when to revise a test to ensuring that his legacy continues long into the future. Although the primary dynamic of these relationships was commercial, the reasons for their success were personal. Common goals, clarity of communication, persistence, respect, and trust allowed these relationships to develop, prosper, evolve, and endure.
Plume RF interference calculations for space shuttle
NASA Technical Reports Server (NTRS)
Boynton, F. P.; Rajasekhar, P. S.
1978-01-01
During a static ground test of a full-scale SRM, measurements of attenuation of the UHF 416.5 MHz Range Safety Signal, the VHF voice link (230 MHz), and of S-band (c. 2.2. GHz) communications links were undertaken. Analyses of these results indicate that measurable attenuation did occur at all test frequencies. The measured attenuation levels are compared with a simple model in which the received signal is identified as that diffracted about the edge of the highly absorbing plume and the signal level in the shadow zone is evaluated using the formula for diffraction at a straight edge. The comparison is satisfactory at VHF and UHF frequencies, and slightly less so at S-band. Reasons for the discrepancies found at higher frequencies are discussed. A revised procedure which appears to relieve the accuracy problem was developed. This procedure is discussed along with applications to high altitude SRM plume attenuation.
Screening for dementia in Arabic: normative data from an elderly Lebanese sample.
Abou-Mrad, Fadi; Chelune, Gordon; Zamrini, Edward; Tarabey, Lubna; Hayek, Maryse; Fadel, Patricia
2017-01-01
Prevention and treatment of dementia is a global concern that requires involvement of international samples. The purpose of this study is to develop culturally sensitive norms based on normal older Lebanese adults using multiple cognitive screening measures translated into Arabic for regional use. Participants were 164 community dwelling older Lebanese adults without cognitive complaints. They were administered the following cognitive measures in Arabic: Alzheimer's Disease 8-item questionnaire, Montreal Cognitive Assessment, Mini Mental Status Exam, Modified Mini Mental Status, Brief Visuospatial Memory Test-Revised, Lebanese Digit Span, Cross-Linguistic Naming Test, and phonemic and semantic fluency tests. Sample characteristics and descriptive statistics for the demographically unadjusted raw scores are first presented (N = 164). Same-form test-retest reliability for each test were computed for 24 participants retested over 2-5 weeks, with reliabilities ranging from .55 to .90; Cronbach alpha coefficients ranged from .34 to .93. Two sets of normative data were constructed. First, base-rates for demographically unadjusted raw scores for the 5th, 10th and 15th percentiles are presented to identify relatively rare occurring performances. Second, using standardized regression-based procedures demographically corrected normative information adjusted for age, education and sex were generated for normative interpretation. Adapting cognitive tests for use in culturally and linguistically diverse regions of the world not only requires careful translation of test instructions and materials, but construction of culturally sensitive local norms. Our normative data should allow for more accurate identification of cognitive impairment and dementia in Arabic-speaking patients, especially those living in Lebanon.
Brenner, Charles
2013-01-01
Approximately two million students matriculate into American colleges and universities per year. Almost 20% of these students begin taking a series of courses specified by advisers of health preprofessionals. The single most important influence on health profession advisers and on course selection for this huge population of learners is the Medical College Admissions Test (MCAT), which was last revised in 1991, 10 years before publication of the first draft human genome sequence. In preparation for the 2015 MCAT, there is a broad discussion among stakeholders of how best to revise undergraduate and medical education in the molecular sciences to prepare researchers and doctors to acquire, analyze and use individual genomic and metabolomic data in the coming decades. Getting these changes right is among the most important educational problems of our era. Copyright © 2012 International Union of Biochemistry and Molecular Biology, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liao, J.; Cao, L.; Ohkawa, K.
2012-07-01
The non-condensable gases condensation suppression model is important for a realistic LOCA safety analysis code. A condensation suppression model for direct contact condensation was previously developed by Westinghouse using first principles. The model is believed to be an accurate description of the direct contact condensation process in the presence of non-condensable gases. The Westinghouse condensation suppression model is further revised by applying a more physical model. The revised condensation suppression model is thus implemented into the WCOBRA/TRAC-TF2 LOCA safety evaluation code for both 3-D module (COBRA-TF) and 1-D module (TRAC-PF1). Parametric study using the revised Westinghouse condensation suppression model ismore » conducted. Additionally, the performance of non-condensable gases condensation suppression model is examined in the ACHILLES (ISP-25) separate effects test and LOFT L2-5 (ISP-13) integral effects test. (authors)« less
Revision Proximal Interphalangeal Arthroplasty: An Outcome Analysis of 75 Consecutive Cases.
Wagner, Eric R; Luo, T David; Houdek, Matthew T; Kor, Daryl J; Moran, Steven L; Rizzo, Marco
2015-10-01
To examine the outcomes and complications associated with revision proximal interphalangeal (PIP) joint arthroplasty. An analysis of 75 consecutive revision PIP joint arthroplasties in 49 patients, performed between 1998 to 2012, was performed. The mean age at the time of surgery was 58 years. Thirty-two patients had a history of prior PIP joint trauma, and 18 patients had rheumatoid arthritis. There were 12 constrained (silicone) implants and 63 nonconstrained implants (34 pyrocarbon and 29 metal-plastic). Over the 14-year period, 19 (25%) fingers underwent a second revision surgery. Second revision surgeries were performed for infection, instability, flexion contracture, and heterotopic ossification. The 2-, 5-, and 10-year survival rates were 80%, 70%, and 70%, respectively, for patients requiring a second revision for PIP joint arthroplasty. Worse outcomes were seen with postoperative dislocations, pyrocarbon implants, and when bone grafting was required. Two operations were complicated by intraoperative fractures, but neither required stabilization. Sixteen patients undergoing revision surgery experienced a postoperative complication, including 2 infections, 1 postoperative fracture, 3 cases of heterotopic ossification, and 10 PIP joint dislocations. The volar approach and the use of a pyrocarbon implant was associated with increased rates of heterotopic ossification, whereas preoperative instability increased the rates of PIP joint dislocation following revision. At a mean of 5.3 years (range, 2-10 years) follow-up, 98% of patients had good pain relief but decreased PIP joint total arc of motion. Proximal interphalangeal joint arthroplasty in the revision setting represents a challenge for surgeons. Revision arthroplasty was associated with a 70% 5-year survival but with a high incidence of complications. Instability was associated with worse outcomes. In this series, silicone and metal-polyethylene implants had lower rates of implant failure and postoperative complications than ones made from pyrocarbon. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Davis, Terry C; Wolf, Michael S; Arnold, Connie L; Byrd, Robert S; Long, Sandra W; Springer, Thomas; Kennen, Estela; Bocchini, Joseph A
2006-12-01
The magnitude and consequences of low literacy in adolescent health and health care are unknown. The purpose of this study was to validate the Rapid Estimate of Adolescent Literacy in Medicine (REALM-Teen), a word-recognition test in English that can be used as a brief literacy-screening tool in health care settings. A total of 1533 adolescents aged 10 to 19 years attending 1 of 5 middle schools, 3 high schools, 1 pediatric clinic, or 2 summer programs in Louisiana and North Carolina participated in face-to-face interviews. Demographic information was solicited, and participants were administered a battery of reading tests, including the REALM-Teen, Wide Range Achievement Test-Revised (WRAT-3), and Slosson Oral Reading Test-Revised (SORT-R). Internal consistency for the REALM-Teen was determined using Cronbach's alpha, and criterion validity was established through correlations with both the WRAT-R and SORT-R. Using reading below grade level (according to SORT-R scores) as an outcome, instrument accuracy and corresponding cutoff scores were calculated by plotting receiver operating characteristic curves and stratum-specific likelihood ratios. Participants were 50% black and 53% female; 34% were enrolled in middle school and 66% in high school. The average time required to administer the REALM-Teen was 3 minutes. Internal consistency was excellent, as was test-retest reliability. The REALM-Teen is strongly correlated with both the WRAT-R and SORT-R. Five reading level categories were identified: 3rd grade and below, 4th to 5th grade, 6th to 7th grade, 8th to 9th grade, and 10th grade and above. Forty-six percent of participants were reading below grade level according to the SORT-R and 28% had repeated at least 1 grade. The REALM-Teen is a brief, reliable instrument for assessing adolescent literacy skills and reading below grade level.
Giannakos, Antonios; Vezeridis, Peter S; Schwartz, Daniel G; Jany, Richard; Lafosse, Laurent
2017-01-01
To describe the technique of an all-arthroscopic Eden-Hybinette procedure in the revision setting for treatment of a failed instability procedure, particularly after failed Latarjet, as well as to present preliminary results of this technique. Between 2007 and 2011, 18 shoulders with persistent instability after failed instability surgery were treated with an arthroscopic Eden-Hybinette technique using an autologous bicortical iliac crest bone graft. Of 18 patients, 12 (9 men, 3 women) were available for follow-up. The average follow-up was 28.8 months (range, 15 to 60 months). A Latarjet procedure was performed as an index surgery in 10 patients (83%). Two patients (17%) had a prior arthroscopic Bankart repair. Eight patients (67%) obtained a good or excellent result, whereas 4 patients (33%) reported a fair or poor result. Seven patients (58%) returned to sport activities. A positive apprehension test persisted in 5 patients (42%), including 2 patients (17%) with recurrent subluxations. The Rowe score increased from 30.00 to 78.33 points (P < .0001). The Walch-Duplay score increased from 11.67 to 76.67 points (P < .0001). The Western Ontario Shoulder Instability Index score showed a good result of 28.71% (603 points). The average anterior flexion was 176° (range, 150° to 180°), and the average external rotation was 66° (range, 0° to 90°). Two patients (16.67%) showed a progression of glenohumeral osteoarthritic changes, with each patient increasing by one stage in the Samilson-Prieto classification. All 4 patients (33%) with a fair or poor result had a nonunion identified on postoperative computed tomography scan. An all-arthroscopic Eden-Hybinette procedure in the revision setting for failed instability surgery, although technically demanding, is a safe, effective, and reproducible technique. Although the learning curve is considerable, this procedure offers all the advantages of arthroscopic surgery and allows reconstruction of glenoid defects and restoration of shoulder stability in this challenging patient population. In our hands, this procedure yields good or excellent results in 67% of patients. Successful outcome is correlated with bony healing of the iliac crest graft to the glenoid. Level IV, therapeutic case series. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Midterm results of Magnum large head metal-on-metal total hip arthroplasty.
Aguado-Maestro, I; Cebrián Rodríguez, E; Paredes Herrero, E; Brunie Vegas, F; Oñate Miranda, M; Fernández García, N; García Alonso, M
2018-06-11
We present the results of the prospective follow up of a sample of large head metal-metal total hip arthroplasty obtained after the safety alert regarding a higher incidence of revision of these implants. All patients implanted with the Recap-M2a-Magnum cup between 2008 and 2011 were included. They were prospectively reviewed recording Harris Hip Score, clinical symptoms of chromium or cobalt intoxication. Serum levels of these ions were requested as well as X-Rays and ultrasonography. An MRI was performed in the cases of positive ultrasonography. Twenty-six males with a mean age of 48.54 years [32-62, SD: 7.18] were included. An anterolateral approach and Bi-Metric (7) and F-40 (19) stems were used. Cephalic diameters ranged 42-52 (mode: 46) and the mean cup inclination was 39.35° [21-59°, SD: 9.78]. During follow-up (7.3 years [5.9-9.4; SD: .78]), 3 patients (11.5%) underwent revision (2 cases aseptic loosening, 1 pseudotumour). Mean time until revision was 5.4 years [3.1-8.0; SD: 2.48]. The accumulated survival probability was 88.5% (95% CI 76.3-100%). Harris Hip Score was 94.47 [66.5-100; SD: 8.94] and the patients showed no metallic intoxication symptoms. The levels of chromium were 1.88 mcg/dl [0.6-3.9] and cobalt 1,74 mcg/dl [0.5-5,6]. One pseudotumour was found in an asymptomatic patient, and small amounts of periarticular liquid were found in 5 patients (19.2%) DISCUSSION AND CONCLUSIONS: High revision rates are still found when follow up is extended due to aseptic loosening and pseudotumour formation. MRI might not be the most adequate test to study the complications of these prostheses. Copyright © 2018 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.
2012-01-01
Background There is a great deal of variation in the existing capacity of primary prevention programs and policies addressing chronic disease to deliver evidence-based interventions (EBIs). In order to develop and evaluate implementation strategies that are tailored to the appropriate level of capacity, there is a need for an easy-to-administer tool to stage organizational readiness for EBIs. Methods Based on theoretical frameworks, including Rogers’ Diffusion of Innovations, we developed a survey instrument to measure four domains representing stages of readiness for EBI: awareness, adoption, implementation, and maintenance. A separate scale representing organizational climate as a potential mediator of readiness for EBIs was also included in the survey. Twenty-three questions comprised the four domains, with four to nine items each, using a seven-point response scale. Representatives from obesity, asthma, diabetes, and tobacco prevention programs serving diverse populations in the United States were surveyed (N = 243); test-retest reliability was assessed with 92 respondents. Results Confirmatory factor analysis (CFA) was used to test and refine readiness scales. Test-retest reliability of the readiness scales, as measured by intraclass correlation, ranged from 0.47–0.71. CFA found good fit for the five-item adoption and implementation scales and resulted in revisions of the awareness and maintenance scales. The awareness scale was split into two two-item scales, representing community and agency awareness. The maintenance scale was split into five- and four-item scales, representing infrastructural maintenance and evaluation maintenance, respectively. Internal reliability of scales (Cronbach’s α) ranged from 0.66–0.78. The model for the final revised scales approached good fit, with most factor loadings >0.6 and all >0.4. Conclusions The lack of adequate measurement tools hinders progress in dissemination and implementation research. These preliminary results help fill this gap by describing the reliability and measurement properties of a theory-based tool; the short, user-friendly instrument may be useful to researchers and practitioners seeking to assess organizational readiness for EBIs across a variety of chronic disease prevention programs and settings. PMID:22800294
Stamatakis, Katherine A; McQueen, Amy; Filler, Carl; Boland, Elizabeth; Dreisinger, Mariah; Brownson, Ross C; Luke, Douglas A
2012-07-16
There is a great deal of variation in the existing capacity of primary prevention programs and policies addressing chronic disease to deliver evidence-based interventions (EBIs). In order to develop and evaluate implementation strategies that are tailored to the appropriate level of capacity, there is a need for an easy-to-administer tool to stage organizational readiness for EBIs. Based on theoretical frameworks, including Rogers' Diffusion of Innovations, we developed a survey instrument to measure four domains representing stages of readiness for EBI: awareness, adoption, implementation, and maintenance. A separate scale representing organizational climate as a potential mediator of readiness for EBIs was also included in the survey. Twenty-three questions comprised the four domains, with four to nine items each, using a seven-point response scale. Representatives from obesity, asthma, diabetes, and tobacco prevention programs serving diverse populations in the United States were surveyed (N=243); test-retest reliability was assessed with 92 respondents. Confirmatory factor analysis (CFA) was used to test and refine readiness scales. Test-retest reliability of the readiness scales, as measured by intraclass correlation, ranged from 0.47-0.71. CFA found good fit for the five-item adoption and implementation scales and resulted in revisions of the awareness and maintenance scales. The awareness scale was split into two two-item scales, representing community and agency awareness. The maintenance scale was split into five- and four-item scales, representing infrastructural maintenance and evaluation maintenance, respectively. Internal reliability of scales (Cronbach's α) ranged from 0.66-0.78. The model for the final revised scales approached good fit, with most factor loadings >0.6 and all >0.4. The lack of adequate measurement tools hinders progress in dissemination and implementation research. These preliminary results help fill this gap by describing the reliability and measurement properties of a theory-based tool; the short, user-friendly instrument may be useful to researchers and practitioners seeking to assess organizational readiness for EBIs across a variety of chronic disease prevention programs and settings.
Revision surgery for failed thermal capsulorrhaphy.
Park, Hyung Bin; Yokota, Atsushi; Gill, Harpreet S; El Rassi, George; McFarland, Edward G
2005-09-01
With the failure of thermal capsulorrhaphy for shoulder instability, there have been concerns with capsular thinning and capsular necrosis affecting revision surgery. To report the findings at revision surgery for failed thermal capsulorrhaphy and to evaluate the technical effects on subsequent revision capsular plication. Case series; Level of evidence, 4. Fourteen patients underwent arthroscopic evaluation and open reconstruction for a failed thermal capsulorrhaphy. The cause of the failure, the quality of the capsule, and the ability to suture the capsule were recorded. The patients were evaluated at follow-up for failure, which was defined as recurrent subluxations or dislocations. The origin of the instability was traumatic (n = 6) or atraumatic (n = 8). At revision surgery in the traumatic group, 4 patients sustained failure of the Bankart repair with capsular laxity, and the others experienced capsular laxity alone. In the atraumatic group, all patients experienced capsular laxity as the cause of failure. Of the 14 patients, the capsule quality was judged to be thin in 5 patients and ablated in 1 patient. A glenoid-based capsular shift could be accomplished in all 14 patients. At follow-up (mean, 35.4 months; range, 22 to 48 months), 1 patient underwent revision surgery and 1 patient had a subluxation, resulting in a failure rate of 14%. Recurrent capsular laxity after failed thermal capsular shrinkage is common and frequently associated with capsular thinning. In most instances, the capsule quality does not appear to technically affect the revision procedure.
Tomasino, Stephen F; Pines, Rebecca M; Hamilton, Gordon C
2012-01-01
(Staphylococcus aureus) and 964.02 (Pseudomonas aeruginosa), were revised in 2009 to include a standardized procedure to measure the log density of the test microbe and to establish a minimum mean log density value of 6.0 (geometric mean of 1.0 x 10(6) CFU/carrier) to qualify the test results. This report proposes setting a maximum mean log density value of 7.0 (geometric mean of 1.0 x 10(7) CFU/carrier) to further standardize the procedure. The minimum value was based on carrier count data collected by four laboratories over an 8-year period (1999-2006). The data have been updated to include an additional 4 years' worth of data (2006-2010) collected by the same laboratories. A total of 512 tests were conducted on products bearing claims against P. aeruginosa and S. aureus with and without an organic soil load (OSL) added to the inoculum (as specified on the product label claim). Six carriers were assayed in each test, for a total of 3072 carriers. Mean log densities for each of the 512 tests were at least 6.0. With the exception of two tests, one for P. aeruginosa without OSL and one for S. aureus with OSL, the mean log densities did not exceed 7.5 (geometric mean of 3.2 x 10(7) CFU/carrier). Across microbes and OSL treatments, the mean log density (+/- SEM) was 6.80 (+/- 0.07) per carrier (a geometric mean of 6.32 x 10(6) CFUlcarrier) and acceptable repeatability (0.28) and reproducibility (0.31) SDs were exhibited. A maximum mean log density per carrier of 7.0 is being proposed here as a validity requirement for S. aureus and P. aeruginosa. A modification to the method to allow for dilution of the final test cultures to achieve carrier counts within 6.0-7.0 logs is also being proposed. Establishing a range of 6.0-7.0 logs will help improve the reliability of the method and should allow for more consistent results within and among laboratories.
Rhodes, Katherine T; Branum-Martin, Lee; Morris, Robin D; Romski, MaryAnn; Sevcik, Rose A
2015-11-01
Although it is often assumed that mathematics ability alone predicts mathematics test performance, linguistic demands may also predict achievement. This study examined the role of language in mathematics assessment performance for children with intellectual disability (ID) at less severe levels, on the KeyMath-Revised Inventory (KM-R) with a sample of 264 children, in grades 2-5. Using confirmatory factor analysis, the hypothesis that the KM-R would demonstrate discriminant validity with measures of language abilities in a two-factor model was compared to two plausible alternative models. Results indicated that KM-R did not have discriminant validity with measures of children's language abilities and was a multidimensional test of both mathematics and language abilities for this population of test users. Implications are considered for test development, interpretation, and intervention.
Kim, Sang Gyun; Jung, Hye-Kyung; Lee, Hang Lak; Jang, Jae Young; Lee, Hyuk; Kim, Chan Gyoo; Shin, Woon Geon; Shin, Ein Soon; Lee, Yong Chan
2014-01-01
The Korean College of Helicobacter and Upper Gastrointestinal Research first developed guidelines for the diagnosis and treatment of Helicobacter pylori (H. pylori) infection in 1998, and revised guidelines were proposed in 2009 by the same group. Although the revised guidelines were based on a comprehensive review of published articles and the consensus of expert opinions, the revised guidelines were not developed using an evidence-based process. The new guidelines presented in this study include specific changes regarding indication and treatment of H. pylori infection in Korea, and were developed through the adaptation process using an evidence-based approach. After systematic review of the literature, six guidelines were selected using the Appraisal of Guidelines for Research and Evaluation (AGREE) II process. A total of 21 statements were proposed with the grading system and revised using the modified Delphi method. After the guideline revisions, 11 statements about indication of test and treatment, four statements about diagnosis, and four statements about treatment of H. pylori infection were developed. The revised guidelines were reviewed by external experts before receiving official endorsement from the Korean College of Helicobacter and Upper Gastrointestinal Research, and disseminated to physicians and other medical professionals for use in clinical practice in Korea. The guidelines will continue to be updated and revised periodically. © 2014 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.
Outcomes Analysis of Chief Cosmetic Clinic Over 13 Years.
Walker, Nicholas J; Crantford, John C; Rudolph, Megan A; David, Lisa R
2018-06-01
Adequate resident training in aesthetic surgery has become increasingly important with rising demand. Chief resident aesthetic clinics allow hands on experience with an appropriate amount of autonomy. The purpose of this study was to compare resident cosmetic clinic outcomes to those reported in the literature. Furthermore, we sought to assess how effective these clinics can be in preparing residents in performing common aesthetic surgery procedures. A retrospective chart review of 326 patients and 714 aesthetic procedures in our chief cosmetic clinic over a 13-year period was performed, and complication and revision rates were recorded. In addition, an electronic survey was sent to 26 prior chief residents regarding their experience and impressions of the chief resident aesthetic clinic. A total of 713 procedures were performed on 326 patients. Patient ages ranged from 5 to 75 years old (mean, 40.8 years old) with a mean follow-up of 76.2 days. On average, there were 56 procedures performed per year. Of the 714 total procedures performed, there were 136 minor procedures and 578 major procedures. Of the 136 minor procedures, there were no complications and there was 1 revision of a cosmetic injection. Of the 578 major procedures, the overall complication rate was 6.1% and the revision rate was 12.8%. Complication and revision rates for each individual surgery were further analyzed and compared with the literature. The complication rates for these procedures fell within the reference ranges reported. In regards to the chief resident survey, there was a 77% response rate. All respondents reported that the chief resident clinic positively affected their residency education and future practice. Ninety percent of respondents felt "very comfortable" performing facelifts, body contouring, and aesthetic breast surgery. No respondents completed a subsequent cosmetic fellowship, and 60% stated that their positive experience in chief clinic contributed to their decision not to pursue a cosmetic fellowship. Chief resident clinics can provide results with acceptable complication and revision rates that fall within the acceptable ranges in the literature. In addition, it provides a valuable experience that leaves residents with high comfort levels in performing key procedures in aesthetic surgery.
Current Status Of The GRACE Follow-On Mission
NASA Astrophysics Data System (ADS)
Flechtner, Frank; Webb, Frank; Watkins, Michael; Landerer, Felix; Dahle, Christoph; Bettadpur, Srinivas
2017-04-01
As of the time of this abstract submission, the GRACE Follow-On satellites have been constructed and transferred to Ottobrunn near Munich for several months of operational testing in the IABG test centre. The Russian/Ukraine Dnepr launcher had to be exchanged and a corresponding new contract has been signed by GFZ and Iridium Satellite LLC. This includes a "Rideshare" between GRACE-FO and 5 Iridium-Next satellites on a Space-X Falcon-9 from Vandenberg Air Force Base in California within the launch period December 2017 till February 2018. The project team is conducting tests of satellite and instrument operation and performance and evaluating updated simulations of expected performance on-orbit, including the assessment of inter-satellite ranging (for both microwave and laser instruments), accelerometer, thermal variability and deformation, and other instrument and measurement errors. In addition, all required ground analysis software of the Science Data System is in development and being tested at JPL, UTCSR, and GFZ, in preparation for fully integrated end-to-end (international) testing from Level-1 through Level-3 data within 2017. In this presentation, we will provide the detailed status of project integration and test, the latest simulations of science performance, and a revised schedule for remaining project milestones.
Rothschild, Beccah; Graham, Carrie; Ivey, Susan L.; Konishi, Susana
2009-01-01
Objectives. We used participatory design methods to develop and test guidebooks about health care choices intended for 600 000 English-, Spanish-, and Chinese-speaking seniors and people with disabilities receiving Medicaid in California. Methods. Design and testing processes were conducted with consumers and professionals; they included 24 advisory group interviews, 36 usability tests, 18 focus groups (105 participants), 51 key informant interviews, guidebook readability and suitability testing, linguistic adaptation, and iterative revisions of 4 prototypes. Results. Participatory design processes identified preferences of intended audiences for guidebook content, linguistic adaptation, and format; guidebook readability was scored at the sixth- to eighth-grade level and suitability at 95%. These findings informed the design of a separate efficacy study that showed high guidebook usage and satisfaction, and better gains in knowledge, confidence, and intended behaviors among intervention participants than among control participants. Conclusions. Participatory design can be used effectively in mass communication to inform vulnerable audiences of health care choices. The techniques described can be adapted for a broad range of health communication interventions. PMID:19833990
Neuhauser, Linda; Rothschild, Beccah; Graham, Carrie; Ivey, Susan L; Konishi, Susana
2009-12-01
We used participatory design methods to develop and test guidebooks about health care choices intended for 600 000 English-, Spanish-, and Chinese-speaking seniors and people with disabilities receiving Medicaid in California. Design and testing processes were conducted with consumers and professionals; they included 24 advisory group interviews, 36 usability tests, 18 focus groups (105 participants), 51 key informant interviews, guidebook readability and suitability testing, linguistic adaptation, and iterative revisions of 4 prototypes. Participatory design processes identified preferences of intended audiences for guidebook content, linguistic adaptation, and format; guidebook readability was scored at the sixth- to eighth-grade level and suitability at 95%. These findings informed the design of a separate efficacy study that showed high guidebook usage and satisfaction, and better gains in knowledge, confidence, and intended behaviors among intervention participants than among control participants. Participatory design can be used effectively in mass communication to inform vulnerable audiences of health care choices. The techniques described can be adapted for a broad range of health communication interventions.
Callaway, Libby; Winkler, Dianne; Tippett, Alice; Herd, Natalie; Migliorini, Christine; Willer, Barry
2016-06-01
Consideration of the relationship between meaningful participation, health and wellbeing underpins occupational therapy intervention, and drives measurement of community integration following acquired brain injury (ABI). However, utility of community integration measures has been limited to date by lack of normative data against which to compare outcomes, and none examine the growing use of electronic social networking (ESN) for social participation. This research had four aims: (i) develop and pilot items assessing ESN to add to the Community Integration Questionnaire, producing the Community Integration Questionnaire-Revised (CIQ-R); (ii) examine factor structure of the CIQ-R; (iii) collect Australian CIQ-R normative data; and (iv) assess test-retest reliability of the revised measure. Australia. A convenience sample of adults without ABI (N = 124) was used to develop and pilot ESN items. A representative general population sample of adults without ABI aged 18-64 years (N = 1973) was recruited to gather normative CIQ-R data. Cross-sectional survey. Demographic items and the CIQ-R. The CIQ-R demonstrated acceptable psychometric properties, with minor modification to the original scoring based on the factor analyses provided. Large representative general population CIQ-R normative data have been established, detailing contribution of a range of independent demographic variables to community integration. The addition of electronic social networking items to the CIQ-R offers a contemporary method of assessing community integration following ABI. Normative CIQ-R data enhance the understanding of community integration in the general population, allowing occupational therapists and other clinicians to make more meaningful comparisons between groups. © 2016 Occupational Therapy Australia.
Mühlhofer, Heinrich M L; Knebel, C; Pohlig, Florian; Feihl, Susanne; Harrasser, Norbert; Schauwecker, Johannes; von Eisenhart-Rothe, Rüdiger
2018-02-01
The two-stage revision protocol is the gold standard for controlling and treating low-grade prosthetic joint infections of total hip and total knee arthroplasty. The antibiotic pause for diagnostic reasons before reconstruction (stage two) is discussed in relation to the persistence of the infection and the development of resistant bacterial strains. Serological markers and a synovial analysis are commonly used to exclude the persistence of infection. Therefore, we asked (1) is the serological testing of C-reactive protein and leucocytes a valuable tool to predict a persistence of infection? and (2) what is the role of synovial aspiration of Plymethylmethacrylat (PMMA) spacers in hip and knee joints? One hundred twelve patients who were MSIS criteria-positive for a prosthetic joint infection were studied, including 45 total hip arthroplasties (THA) and 67 total knee artrhoplasties (TKA) patients. All patients were treated with a two-stage-protocol using a mobile PMMA spacer after a 14-day antibiotic-free interval, during which we measured serological markers (C-reactive protein and leucocytes) and performed synovial aspiration (white blood cell count, polymorphonuclear cell percentage, and microbiological culture) in these patients and compared the results with those of their long-term-follow-up (mean follow-up 27 months, range 24-36 months). Of the 112 patients, 89 patients (79.5%; 95% CI 72-86.9) exhibited infection control after a two-stage exchange, and we detected most methicillin-resistant, coagulase-negative Staphylococci (CoNS) in cases of a persistent infection. The mean sensitivity of serum C-reactive protein in the patients was 0.43 (range 0.23-0.64), and the mean specificity was 0.73 (range 0.64-0.82). For serum leucocytes, the mean sensitivity was 0.09 (range 0-0.29), and the mean specificity was 0.81 (range 0.7-0.92). The mean sensitivity for the WBC count in the synovial fluid (PMMA spacer aspiration) was 0.1 (range 0-0.29), and the mean specificity was 0.79 (range 0.68-0.92). For the PMN percentage, the mean sensitivity was 0.1 (range 0-0.29), and the mean specificity was 0.79 (range 0.68-0.92). No cut-off values could be established for C-reactive protein, leucocytes, WBC count and PMN percentage due to the low AUC. No reliable markers were identified for the long-term persistence of infection. C-reactive protein and leucocytes were often elevated, even when the infection was controlled. In addition, normalized serum markers did not exclude the persistence of infection during follow-up. The synovial analysis of the WBC count and PMN percentage did not predict the persistence of infection. However, microbiological synovial fluid analysis is often misleading due to false positive microbiological cultures, which results in overtreatment.
ERIC Educational Resources Information Center
Morrissey, Catrin; Cooke, David; Michie, Christine; Hollin, Clive; Hogue, Todd; Lindsay, William R.; Taylor, John L.
2010-01-01
The Psychopathy Checklist-Revised (PCL-R) is the most widely used measure of psychopathy in forensic clinical practice, but the generalizability of the measure to offenders with intellectual disabilities (ID) has not been clearly established. This study examined the structural equivalence and scalar equivalence of the PCL-R in a sample of 185 male…
Revision of ISO 15859 Aerospace Fluid Standards
NASA Technical Reports Server (NTRS)
Greene, Benjamin; McClure, Mark B.
2012-01-01
A detailed review of ISO 15859 "Space Systems - Fluid Characteristics, Sampling and Test Methods" was performed An approach to revising Parts 1-9 and 11-13 was developed and concurred by the NASA Technical Standards Program Office. The approach was to align them with the highest level source documents, and not to program-specific requirements. The updated documents were prepared and presented.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-09
... Standard Review Plan, Section 14.3.12 on Physical Security Hardware Inspections, Tests, Analyses, and.... SUMMARY: The NRC is soliciting public comment on NUREG-0800, ``Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants,'' on a proposed Revision 1 to Standard Review Plan (SRP...
ERIC Educational Resources Information Center
Liu, Haixia; Lin, Chin-Hsi; Zhang, Dongbo
2017-01-01
Though pedagogical beliefs have been identified as critical factors in the success of technology integration, very few studies have included them in technology-adoption models. The present study revises the Technology Acceptance Model (TAM) by adding teachers' pedagogical beliefs, and tests the revised model among university-level…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-24
... time that a document is referenced. Revision 3 of Regulatory Guide 1.129 is available in ADAMS under...-251-7455; email: [email protected] . Both of the Office of Nuclear Regulatory Research, U.S... NRC is issuing a revision to an existing guide in the NRC's ``Regulatory Guide'' series. This series...
ERIC Educational Resources Information Center
Sabatino, David A.; And Others
1995-01-01
This study determines the comparability of the Wechsler Intelligence Scale for Children-Revised and the Wechsler Intelligence Scale for Children-III in relation to gifted children. Results indicate that both tests produce remarkably similar scale and subtest scores when administered under clinical conditions. (JPS)
ERIC Educational Resources Information Center
Jowett, Tim; Harraway, John; Lovelock, Brent; Skeaff, Sheila; Slooten, Liz; Strack, Mick; Shephard, Kerry
2014-01-01
Higher education is increasingly interested in its impact on the sustainability attributes of its students, so we wanted to explore how our students' environmental concern changed during their higher education experiences. We used the Revised New Ecological Paradigm Scale (NEP) with 505 students and developed and tested a multinomial…
Individualized In-Service Teacher Education. (Project IN-STEP). Evaluation Report, Phase II.
ERIC Educational Resources Information Center
Thurber, John C.
Phase 2 of Project IN-STEP was conducted to revise, refine, and conduct further field testing of a new inservice teacher education model. The method developed (in Phase 1--see ED 003 905 for report) is an individualized, multi-media approach. Revision activities, based on feedback provided for Phase 1, include the remaking of six videotape…
Code of Federal Regulations, 2012 CFR
2012-07-01
... coupled plasma-atomic emission spectrometry (AVICP-AES) 200.5, Revision 4.2. 2 Arsenic Atomic Absorption... inductively coupled plasma-atomic emission spectrometry (AVICP-AES) 200.5, Revision 4.2. 2 Barium Inductively Coupled Plasma 3120 B Atomic Absorption; Direct 3111 D Atomic Absorption; Furnace 3113 B 3113 B-04 Axially...
Code of Federal Regulations, 2011 CFR
2011-07-01
... coupled plasma-atomic emission spectrometry (AVICP-AES) 200.5, Revision 4.2. 2 Arsenic Atomic Absorption... inductively coupled plasma-atomic emission spectrometry (AVICP-AES) 200.5, Revision 4.2. 2 Barium Inductively Coupled Plasma 3120 B Atomic Absorption; Direct 3111 D Atomic Absorption; Furnace 3113 B 3113 B-04 Axially...
ERIC Educational Resources Information Center
Douglas, Kevin S.; Guy, Laura S.; Edens, John F.; Boer, Douglas P.; Hamilton, Jennine
2007-01-01
The Personality Assessment Inventory's (PAI's) ability to predict psychopathic personality features, as assessed by the Psychopathy Checklist-Revised (PCL-R), was examined. To investigate whether the PAI Antisocial Features (ANT) Scale and subscales possessed incremental validity beyond other theoretically relevant PAI scales, optimized regression…
Development of QC Procedures for Ocean Data Obtained by National Research Projects of Korea
NASA Astrophysics Data System (ADS)
Kim, S. D.; Park, H. M.
2017-12-01
To establish data management system for ocean data obtained by national research projects of Ministry of Oceans and Fisheries of Korea, KIOST conducted standardization and development of QC procedures. After reviewing and analyzing the existing international and domestic ocean-data standards and QC procedures, the draft version of standards and QC procedures were prepared. The proposed standards and QC procedures were reviewed and revised by experts in the field of oceanography and academic societies several times. A technical report on the standards of 25 data items and 12 QC procedures for physical, chemical, biological and geological data items. The QC procedure for temperature and salinity data was set up by referring the manuals published by GTSPP, ARGO and IOOS QARTOD. It consists of 16 QC tests applicable for vertical profile data and time series data obtained in real-time mode and delay mode. Three regional range tests to inspect annual, seasonal and monthly variations were included in the procedure. Three programs were developed to calculate and provide upper limit and lower limit of temperature and salinity at depth from 0 to 1550m. TS data of World Ocean Database, ARGO, GTSPP and in-house data of KIOST were analysed statistically to calculate regional limit of Northwest Pacific area. Based on statistical analysis, the programs calculate regional ranges using mean and standard deviation at 3 kind of grid systems (3° grid, 1° grid and 0.5° grid) and provide recommendation. The QC procedures for 12 data items were set up during 1st phase of national program for data management (2012-2015) and are being applied to national research projects practically at 2nd phase (2016-2019). The QC procedures will be revised by reviewing the result of QC application when the 2nd phase of data management programs is completed.
INTERNATIONAL REPORT: Revised Values for (t90 - t68) from 630°C to 1064°C
NASA Astrophysics Data System (ADS)
Rusby, R. L.; Hudson, R. P.; Durieux, M.
1994-01-01
A revised table of differences (t90 - t68) between values of temperature on the International Temperature Scale of 1990, ITS-90, and the corresponding values on the International Practical Temperature Scale of 1968, IPTS-68, is published at the request of the Comité Consultatif de Thermométrie (CCT). The revision affects only the range 630°C to 1064°C, where the IPTS-68 specified the use of platinum-10% rhodium versus platinum thermocouples. It follows from new intercomparisons of thermocouples carrying IPTS-68 calibrations with platinum resistance thermometers and radiation thermometers calibrated in accordance with the ITS-90. The largest change occurs at 760°C, where the difference formerly tabulated as 0,36°C is now 0,04°C. The revision concerns only the assessment of the differences between the ITS-90 and the IPTS-68, and does not affect the ITS-90 in any way.
Do Changes in the Production Process Affect the Outcome of Ceramic Liners: A 3-Year Follow-Up Study.
Schmidt-Braekling, Tom; Renner, Lisa; Mintz, Douglas N; Waldstein, Wenzel; Endo, Yoshimi; Boettner, Friedrich
2017-04-01
In 2011, the current liner was withdrawn from the market because of the potential risk for liner fracture secondary to increased pressures used to assemble the metal locking ring. The present study provides a short-term follow-up of patients with this implant. We retrospectively evaluated 63 consecutive hips in 53 patients operated by a single surgeon using a recalled ceramic-on-ceramic bearing. There were 30 women and 23 men with an average age of 50.6 years (range 20.3-63.5 years). The mean follow-up was 36.8 months. Six hips in 6 patients were revised (9.5%) because of a liner-fracture during the follow-up period. All liner fractures were identified on computer tomography imaging. Nine patients had self-reported episodes of squeaking (14.3%). All 6 patients that underwent revision surgery for liner fracture described squeaking before revision. There were no revisions for other causes. Two of the revised patients had a subsequent dislocation (33%). The recalled ceramic liner lots have an increased liner fracture rate. Patients with mechanical symptoms or squeaking should undergo computer tomography to rule out liner facture. Copyright © 2016 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Orendorff, Christopher; Lamb, Joshua; Steele, Leigh Anna Marie
This report describes recommended abuse testing procedures for rechargeable energy storage systems (RESSs) for electric vehicles. This report serves as a revision to the FreedomCAR Electrical Energy Storage System Abuse Test Manual for Electric and Hybrid Electric Vehicle Applications (SAND2005-3123).
Gliatis, John; Megas, Panagiotis; Panagiotopoulos, Elias; Lambiris, Elias
2005-03-01
Although the short-term results of supracondylar periprosthetic fractures treated with retrograde nailing have been satisfactory, there is always a concern about the long-term survival of the prosthesis. The aim of the study was to evaluate fracture healing and knee functional outcome with a follow-up time of at least 2 years in periprosthetic fractures of the knee treated with a supracondylar nail. Cohort study. There were 9 patients with 10 periprosthetic fractures. In 1 patient, the fracture occurred intraoperatively. In the others, the time between the total knee arthroplasty and the periprosthetic fracture ranged between 2 weeks and 7 years (average time: 2.78 years). The mean follow-up was 34.5 months (25-52 months). The Western Ontario and McMaster Universities index was used to evaluate the functional result postoperatively using the paired t test as the statistical test. Fracture union was assessed with plain x-rays. All the fractures united within 3 months. One fracture united in extreme valgus (35 degrees) and was revised to a stemmed total knee replacement. There were no infections and no prosthesis loosening. The paired t test before the fracture and after the operation demonstrated no statistically significant differences; however, there was a trend toward lower functional score postoperatively. It appears that retrograde nailing is a reliable technique to treat periprosthetic supracondylar fractures. It provides adequate stability until fracture union. The morbidity of the operation is minimal, and the complication rate is low. The midterm results in our study showed that none of the prostheses required revision. In our opinion, it is the treatment of choice for a periprosthetic fracture when the prosthesis is stable.
The development and validation of the client expectations of massage scale.
Boulanger, Karen T; Campo, Shelly; Glanville, Jennifer L; Lowe, John B; Yang, Jingzhen
2012-01-01
Although there is evidence that client expectations influence client outcomes, a valid and reliable scale for measuring the range of client expectations for both massage therapy and the behaviors of their massage therapists does not exist. Understanding how client expectations influence client outcomes would provide insight into how massage achieves its reported effects. To develop and validate the Client Expectations of Massage Scale (CEMS), a measure of clients' clinical, educational, interpersonal, and outcome expectations. Offices of licensed massage therapists in Iowa. A practice-based research methodology was used to collect data from two samples of massage therapy clients. For Sample 1, 21 volunteer massage therapists collected data from their clients before the massage. Factor analysis was conducted to test construct validity and coefficient alpha was used to assess reliability. Correlational analyses with the CEMS, previous measures of client expectations, and the Life Orientation Test-Revised were examined to test the convergent and discriminant validity of the CEMS. For Sample 2, 24 massage therapists distributed study materials for clients to complete before and after a massage therapy session. Structural equation modeling was used to assess the construct, discriminant, and predictive validity of the CEMS. Sample 1 involved 320 and Sample 2 involved 321 adult massage clients. Standard care provided by licensed massage therapists. Numeric Rating Scale for pain and Positive and Negative Affect Schedule-Revised (including the Serenity subscale). The CEMS demonstrated good construct, convergent, discriminant and predictive validity, and adequate reliability. Client expectations were generally positive toward massage and their massage therapists. Positive outcome expectations had a positive effect on clients' changes in pain and serenity. High interpersonal expectations had a negative effect on clients' changes in serenity. Client expectations contribute to the nonspecific effects of massage therapy.
Principles and Procedures for Evaluating the Toxicity of Household Substances. Revised.
ERIC Educational Resources Information Center
National Academy of Sciences - National Research Council, Washington, DC. Assembly of Life Sciences.
This report was prepared for use by the professional toxicologist. It contains chapters on ingestion exposure, dermal and dye toxicity tests, inhalation exposure, chronic toxicity and carcinogenicity tests, mutagenicity tests, reproduction and teratogenicity tests, and behavioral toxicity tests. In addition, regulations under the Federal Hazardous…
78 FR 62488 - Energy Conservation Program: Compliance Date for the Dehumidifier Test Procedure
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-22
... Conservation Program: Compliance Date for the Dehumidifier Test Procedure AGENCY: Office of Energy Efficiency.... Department of Energy (DOE) proposes to revise the compliance date for the dehumidifier test procedures... manufacturers to test using only the active mode provisions in the test procedure for dehumidifiers currently...
Extended Experience with Neuroendoscopic Lavage for Posthemorrhagic Hydrocephalus in Neonates.
d'Arcangues, Charlotte; Schulz, Matthias; Bührer, Christoph; Thome, Ulrich; Krause, Matthias; Thomale, Ulrich-Wilhelm
2018-05-03
Previous studies have described neuroendoscopic lavage (NEL) as a procedure for the treatment of posthemorrhagic hydrocephalus in newborn infants. This report describes complications and results in an extended case series from 2 separate hospitals. Patient records were screened for NEL procedures performed on infants with posthemorrhagic hydrocephalus between September 2010 and May 2016 (minimum follow-up period of 12 months). Efficacy of blood removal-as assessed with cerebral ultrasound, complications, eventual shunt placement rate, and subsequent shunt revisions-were recorded. Fifty-six patients (35 male) underwent NEL at a postmenstrual median age of 31 weeks and 2 days (range, 26 weeks and 1 day to 52 weeks and 3 days) and a median weight of 1523 g (range, 734-4360 g). Median follow-up was 34 months (range, 12-80). Three patients died, and 31 patients required permanent ventriculoperitoneal shunting. There was no significant correlation between the need for ventriculoperitoneal shunting and gestational age (P = 0.05), birth weight (P = 0.07), age (P = 0.17), or weight (P = 0.59) after NEL. The median number of surgical interventions per patient was 2 (range, 1-7 interventions). Revision-free shunt survival was 63.6% at 12 and 56.2% at 24 months. NEL avoided shunt placement in 43% of newborn infants with posthemorrhagic hydrocephalus. In the shunted cohort, NEL may have also decreased the frequency of subsequent shunt revisions. The influence of NEL on neurodevelopment and safety remains to be investigated further in a multicenter setup. Copyright © 2018 Elsevier Inc. All rights reserved.
Physics and the revised Medical College Admission Test
NASA Astrophysics Data System (ADS)
Hilborn, Robert C.
2014-05-01
Physics has played an important role in the preparation of future physicians and other health professionals for more than 100 years. Almost all pre-health students take a year of college-level physics as part of their preparation for medical, dental, and pharmacy school. In particular, the widely-used Medical College Admission Test (MCAT) contains a significant number of questions that require physics knowledge and skills. This paper describes the changes in the MCAT to be implemented in 2015, the role of physics in the revised MCAT, and implications for introductory physics courses for the life sciences.
Lee, T H; Moon, J H; Kim, J H; Park, D H; Lee, S S; Choi, H J; Cho, Y D; Park, S H; Kim, S J
2013-01-01
Endoscopic bilateral drainage for inoperable malignant hilar biliary strictures (HBS) using metal stents is considered to be technically difficult. Furthermore, endoscopic revision of bilateral stenting after occlusion can be challenging. This study was performed to evaluate the long-term efficacy of endoscopic bilateral stent-in-stent placement of cross-wired metallic stents in high-grade malignant HBS and planned endoscopic bilateral revision. A total of 84 patients with inoperable high-grade malignant HBS were enrolled from three academic tertiary referral centers. Two cross-wired metal stents were inserted using a bilateral stent-in-stent placement method. Bilateral endoscopic revision was also performed during follow-up using either identical metal stents or plastic stents. The main outcome measurements were technical and functional success, complications, stent patency, and endoscopic revision efficacy. The technical and clinical success rates of endoscopic bilateral stent-in-stent placement of cross-wired metallic stents were 95.2% (80/84) and 92.9% (78/84), respectively. Median patency (range) and survival were 238 days (10-429) and 256 days (10-1130), respectively. Obstruction of primary bilateral stents occurred in 30.8% (24/78) of patients with functionally successful stent placement. The technical and clinical success rates of planned bilateral endoscopic revision for occluded stents were 83.3% (20/24) and 79.2% (19/24), respectively. For revision, bilateral metallic stents were placed in 11 patients (55.0%); the remaining patients received plastic stents. Palliative endoscopic bilateral stent-in-stent placement of cross-wired metallic stents was effective in patients with inoperable HBS. Revision endoscopic bilateral stenting may be feasible and successful in cases where the primary deployed metal stents are occluded. © Georg Thieme Verlag KG Stuttgart · New York.
Patients and medical statistics. Interest, confidence, and ability.
Woloshin, Steven; Schwartz, Lisa M; Welch, H Gilbert
2005-11-01
People are increasingly presented with medical statistics. There are no existing measures to assess their level of interest or confidence in using medical statistics. To develop 2 new measures, the STAT-interest and STAT-confidence scales, and assess their reliability and validity. Survey with retest after approximately 2 weeks. Two hundred and twenty-four people were recruited from advertisements in local newspapers, an outpatient clinic waiting area, and a hospital open house. We developed and revised 5 items on interest in medical statistics and 3 on confidence understanding statistics. Study participants were mostly college graduates (52%); 25% had a high school education or less. The mean age was 53 (range 20 to 84) years. Most paid attention to medical statistics (6% paid no attention). The mean (SD) STAT-interest score was 68 (17) and ranged from 15 to 100. Confidence in using statistics was also high: the mean (SD) STAT-confidence score was 65 (19) and ranged from 11 to 100. STAT-interest and STAT-confidence scores were moderately correlated (r=.36, P<.001). Both scales demonstrated good test-retest repeatability (r=.60, .62, respectively), internal consistency reliability (Cronbach's alpha=0.70 and 0.78), and usability (individual item nonresponse ranged from 0% to 1.3%). Scale scores correlated only weakly with scores on a medical data interpretation test (r=.15 and .26, respectively). The STAT-interest and STAT-confidence scales are usable and reliable. Interest and confidence were only weakly related to the ability to actually use data.
Lamiani, Giulia; Setti, Ilaria; Barlascini, Luca; Vegni, Elena; Argentero, Piergiorgio
2017-03-01
Moral distress is a common experience among critical care professionals, leading to frustration, withdrawal from patient care, and job abandonment. Most of the studies on moral distress have used the Moral Distress Scale or its revised version (Moral Distress Scale-Revised). However, these scales have never been validated through factor analysis. This article aims to explore the factorial structure of the Moral Distress Scale-Revised and develop a valid and reliable scale through factor analysis. Validation study using a survey design. Eight medical-surgical ICUs in the north of Italy. A total of 184 clinicians (64 physicians, 94 nurses, and 14 residents). The Moral Distress Scale-Revised was translated into Italian and administered along with a measure of depression (Beck Depression Inventory-Second Edition) to establish convergent validity. Exploratory factor analysis was conducted to explore the Moral Distress Scale-Revised factorial structure. Items with low (less than or equal to 0.350) or multiple saturations were removed. The resulting model was tested through confirmatory factor analysis. The Italian Moral Distress Scale-Revised is composed of 14 items referring to four factors: futile care, poor teamwork, deceptive communication, and ethical misconduct. This model accounts for 59% of the total variance and presents a good fit with the data (root mean square error of approximation = 0.06; comparative fit index = 0.95; Tucker-Lewis index = 0.94; weighted root mean square residual = 0.65). The Italian Moral Distress Scale-Revised evinces good reliability (α = 0.81) and moderately correlates with Beck Depression Inventory-Second Edition (r = 0.293; p < 0.001). No significant differences were found in the moral distress total score between physicians and nurses. However, nurses scored higher on futile care than physicians (t = 2.051; p = 0.042), whereas physicians scored higher on deceptive communication than nurses (t = 3.617; p < 0.001). Moral distress was higher for those clinicians considering to give up their position (t = 2.778; p = 0.006). The Italian Moral Distress Scale-Revised is a valid and reliable instrument to assess moral distress among critical care clinicians and develop tailored interventions addressing its different components. Further research could test the generalizability of its factorial structure in other cultures.
Students' Initial Knowledge State and Test Design: Towards a Valid and Reliable Test Instrument
ERIC Educational Resources Information Center
CoPo, Antonio Roland I.
2015-01-01
Designing a good test instrument involves specifications, test construction, validation, try-out, analysis and revision. The initial knowledge state of forty (40) tertiary students enrolled in Business Statistics course was determined and the same test instrument undergoes validation. The designed test instrument did not only reveal the baseline…
Biology and control of hemlock woolly adelgid
Nathan P. Havill; Ligia C. Vieira; Scott M. Salom
2014-01-01
This publication is a substantial revision of FHTET 2001-03, Hemlock Woolly Adelgid, which was published in 2001. This publication contains information on the native range of hemlock and range of hemlock woolly adelgid, the importance of hemlocks in eastern forest ecosystems, and on hosts, life cycle, control, and population trends of the hemlock woolly adelgid.
77 FR 38278 - Collection Revision
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-27
... vehicles because they use an electric battery as the primary energy source for propulsion for a limited range (15-40 miles) before switching to internal combustion propulsion. Currently, EIA collects data on...
Live load testing and load rating of five reinforced concrete bridges.
DOT National Transportation Integrated Search
2014-10-01
Five cast-in-place concrete T-beam bridges Eustis #5341, Whitefield #3831, Cambridge #3291, Eddington #5107, : and Albion #2832 were live load tested. Revised load ratings were computed either using test data or detailed : analysis when possi...
Standards for Educational and Psychological Testing, 2014 Edition
ERIC Educational Resources Information Center
American Educational Research Association (AERA), 2014
2014-01-01
Developed jointly by the American Educational Research Association, American Psychological Association, and the National Council on Measurement in Education, "Standards for Educational and Psychological Testing" (Revised 2014) addresses professional and technical issues of test development and use in education, psychology, and…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-04
... Conservation Program: Test Procedures for Residential Clothes Washers; Correction AGENCY: Office of Energy.... Department of Energy (DOE) is correcting a final rule establishing revised test procedures for residential... factor calculation section of the currently applicable test procedure. DATES: Effective: April 6, 2012...
Pritchett, James W
2015-07-01
One of the goals of a TKA is to approximate the function of a normal knee. Preserving the natural ligaments might provide a method of restoring close to normal function. Sacrifice of the ACL is common and practical during a TKA. However, this ligament is functional in more than 60% of patients undergoing a TKA and kinematic studies support the concept of bicruciate-retaining (that is, ACL-preserving) TKA; however, relatively few studies have evaluated patients treated with bicruciate-retaining TKA implants. I asked: (1) what is the long-term (minimum 20-year) survivorship, (2) what are the functional results, and (3) what are the reasons for revision of bicruciate-retaining knee arthroplasty prostheses? From January 1989 to September 1992, I performed 639 total knee replacements in 537 patients. Of these, 489 were performed in 390 patients using a bicruciate-retaining, minimally constrained device. During the period in question, this knee prosthesis was used for all patients observed intraoperatively to have an intact, functional ACL with between 15° varus and 15° valgus joint deformity. There were 234 women and 156 men with a mean age at surgery of 65 years (range, 42-84 years) and a primary diagnosis of osteoarthritis in 89%. The patella was resurfaced in all knees. The mean followup was 23 years (range, 20-24 years). At the time of this review, 199 (51%) patients had died and 31 (8%) patients were lost to followup, leaving 160 (41%) patients (214 knees) available for review. Component survivorship was determined by competing-risks analysis and Kaplan Meier survivorship analysis with revision for any reason as the primary endpoint. Patients were evaluated every 2 years to assess ROM, joint laxity, knee stability, and to determine American Knee Society scores. The Kaplan-Meier survivorship was 89% (95% CI, 82%-93%) at 23 years with revision for any reason as the endpoint. Competing-risks survivorship was 94% (95% CI, 91%%-96 %) at 23 years. At followup, the mean age of the patients was 84 years (range, 63-101 years), the mean flexion was 117° (range, 90°-130°), the mean American Knee Society score improved from a preoperative mean of 42 (range, 26-49) to 91 (range, 61-100; p < .001). Twenty-two knees in 21 patients (5.6%) were revised, most commonly because of polyethylene wear. ACL sacrifice may be an unnecessary concession during TKA. This study found satisfactory survivorship and function after more than 20 years of use for patients receiving a bicruciate-retaining TKA implant. A TKA that preserves cruciate ligaments provides a stable, well-functioning knee with a low likelihood of revision at long-term followup. Retaining both cruciate ligaments during knee arthroplasty is an attractive concept that is worth considering. Level IV, therapeutic study.
Killingsworth, Erin; Kimble, Laura P; Sudia, Tanya
2015-01-01
To explore the decision-making process of BSN faculty when determining which best practices to use for classroom testing. A descriptive, correlational study was conducted with a national sample (N = 127) of full-time BSN faculty. Participants completed a web-based survey incorporating instruments that measured beliefs about evaluation, decision-making, and best practices for item analysis and constructing and revising classroom tests. Study participants represented 31 states and were primarily middle-aged white women. In multiple linear regression analyses, faculty beliefs, contextual factors for decision-making, and decision-making processes accounted for statistically significant amounts of the variance in item analysis and test construction and revision. Strong faculty beliefs that rules were important when evaluating students was a significant predictor of increased use of best practices. Results support that understanding faculty beliefs around classroom testing is important in promoting the use of best practices.
Tests of a habitat suitability model for black-capped chickadees
Schroeder, Richard L.
1990-01-01
The black-capped chickadee (Parus atricapillus) Habitat Suitability Index (HSI) model provides a quantitative rating of the capability of a habitat to support breeding, based on measures related to food and nest site availability. The model assumption that tree canopy volume can be predicted from measures of tree height and canopy closure was tested using data from foliage volume studies conducted in the riparian cottonwood habitat along the South Platte River in Colorado. Least absolute deviations (LAD) regression showed that canopy cover and over story tree height yielded volume predictions significantly lower than volume estimated by more direct methods. Revisions to these model relations resulted in improved predictions of foliage volume. The relation between the HSI and estimates of black-capped chickadee population densities was examined using LAD regression for both the original model and the model with the foliage volume revisions. Residuals from these models were compared to residuals from both a zero slope model and an ideal model. The fit model for the original HSI differed significantly from the ideal model, whereas the fit model for the original HSI did not differ significantly from the ideal model. However, both the fit model for the original HSI and the fit model for the revised HSI did not differ significantly from a model with a zero slope. Although further testing of the revised model is needed, its use is recommended for more realistic estimates of tree canopy volume and habitat suitability.
Ardeshirpour, Farhad; Hurliman, Elisabeth; Wendelschafer-Crabb, Gwen; McAdams, Brian; Hilger, Peter A; Kennedy, William R; Lassig, Amy Anne D; Brenner, Michael J
2017-09-01
Wound healing influences both the cosmetic and functional outcomes of facial surgery. Study of cutaneous innervation may afford insight into patients' preoperative wound healing potential and aid in their selection of appropriate surgical procedures. To present the quantitative and qualitative differences of epidermal nerve fibers (ENFs), neurotransmitters, vasculature, and mast cells in facial skin among patients after primary and revision rhytidectomies. This pilot study collected cutaneous specimens from 8 female patients aged 42 to 66 years who underwent primary rhytidectomy (n = 5) and revision rhytidectomy (n = 3) at Centennial Lakes Surgery Center, Edina, Minnesota, from July 2010 to March 2014. Tissue was processed for confocal/epifluorescence microscopy and indirect immunofluorescent localization of several neural and tissue antigens as well as basement membrane and mast cell markers. Primary rhytidectomy vs revision rhytidectomy with selection of a small area of redundant, otherwise disposed of tissue anterior to the tragus for ENF study. Demographic characteristics included smoking status; 10-point rating scales for facial sensation, pain, and paresthesias; and confocal/epifluorescence microscopy to quantify ENFs, neurotransmitters, vasculature, and mast cells. Patients in the primary rhytidectomy group had a mean (SD) of 54.4 (31.6) ENFs/mm (range, 14.2-99.2 ENFs/mm), and those in the revision rhytidectomy group had a mean (SD) of 18.6 (5.8) ENFs/mm (range, 13.8-25.0 ENFs/mm). A patient in the primary rhytidectomy group was a 25-pack-year smoker and had 14.2 ENFs/mm, the lowest in both groups. In addition to these structural neural changes, functional neural changes in revision rhytidectomy samples included qualitative changes in normal neural antigen prevalence (substance P, calcitonin gene-related peptide, and vasoactive intestinal peptide). Capillary loops appeared less robust and were less common in dermal papilla among samples from both the primary and revision groups, and mast cells were more degranulated. No differences were found in subjective, self-reported postoperative facial sensation. Previous skin elevation was associated with decreased epidermal nerve fiber density and qualitative changes in dermal nerves, capillaries, and mast cells in a clinical sample of patients undergoing rhytidectomy. Future research is needed to determine whether histological findings predict wound healing and to better understand the effects of surgery on regenerative capacity of epidermal nerve fibers. NA.
Nutritional Assessment of the Ft. Riley Non-Commissioned Officer Academy Dining Facility
1987-05-01
Initiatives, Revised Armed Forces Recipe Service, Cholesterol Consumption, Sodium, Fat Reduction, Visual Portion Estimation. Garrison Dining Facility...moderate cholesterol intakes vii i Ue should be evaluated. Revised Armed Forces Recipe Service recipes with reduced salt content should be tested and...preparation methods used and recipes followed in the NCO Academy Dining Facility. Standard recipes from the Armed Forces Recipe Service Tri-Service
Stability of Scores on Super's Work Values Inventory-Revised
ERIC Educational Resources Information Center
Leuty, Melanie E.
2013-01-01
Test-retest data on Super's Work Values Inventory-Revised for a group of predominantly White ("N" = 995) women (mean age = 23.5 years, SD = 8.07) and men (mean age = 21.5 years, SD = 5.80) showed stability in mean-level scores over a period of 1 year for the sample as a whole. However, low raw score and rank order stability coefficients…
ERIC Educational Resources Information Center
Matson, Johnny L.; Hess, Julie A.; Mahan, Sara; Fodstad, Jill C.
2010-01-01
The purpose of this paper was to further establish the validity of the Autism Spectrum Disorder-Diagnostic for Children (ASD-DC). The methodology consisted of testing the similarity of findings between the ASD-DC and the Autism Diagnostic Interview-Revised (ADI-R), which proved to be statistically significant for subscale content scores on social,…
ERIC Educational Resources Information Center
Hu, Bi Ying
2015-01-01
This study examined the degrees of congruence between two early childhood evaluation systems on various quality concepts: the Early Childhood Environment Rating Scale-Revised (ECERS-R) and Zhejiang's Kindergarten Quality Rating System (KQRS). Analysis of variance and post hoc least significant difference tests were employed to show the extent to…
ERIC Educational Resources Information Center
Schretlen, David; And Others
1994-01-01
Composite reliability and standard errors of measurement were computed for prorated Verbal, Performance, and Full-Scale intelligence quotient (IQ) scores from a seven-subtest short form of the Wechsler Adult Intelligence Scale-Revised. Results with 1,880 adults (standardization sample) indicate that this form is as reliable as the complete test.…
ERIC Educational Resources Information Center
Kissel, Stanley; Kissel, Pearl
The major purpose of this work is to provide information for teachers about intelligence testing; more specifically, how the revised Wechsler Intelligence Scale for Children (WISC-R) can be used practically. The purpose is not to make teachers into testers, but rather to make them more sophisticiated users of the information that they obtain from…
Supernova Driving. IV. The Star-formation Rate of Molecular Clouds
NASA Astrophysics Data System (ADS)
Padoan, Paolo; Haugbølle, Troels; Nordlund, Åke; Frimann, Søren
2017-05-01
We compute the star-formation rate (SFR) in molecular clouds (MCs) that originate ab initio in a new, higher-resolution simulation of supernova-driven turbulence. Because of the large number of well-resolved clouds with self-consistent boundary and initial conditions, we obtain a large range of cloud physical parameters with realistic statistical distributions, which is an unprecedented sample of star-forming regions to test SFR models and to interpret observational surveys. We confirm the dependence of the SFR per free-fall time, SFRff, on the virial parameter, α vir, found in previous simulations, and compare a revised version of our turbulent fragmentation model with the numerical results. The dependences on Mach number, { M }, gas to magnetic pressure ratio, β, and compressive to solenoidal power ratio, χ at fixed α vir are not well constrained, because of random scatter due to time and cloud-to-cloud variations in SFRff. We find that SFRff in MCs can take any value in the range of 0 ≤ SFRff ≲ 0.2, and its probability distribution peaks at a value of SFRff ≈ 0.025, consistent with observations. The values of SFRff and the scatter in the SFRff-α vir relation are consistent with recent measurements in nearby MCs and in clouds near the Galactic center. Although not explicitly modeled by the theory, the scatter is consistent with the physical assumptions of our revised model and may also result in part from a lack of statistical equilibrium of the turbulence, due to the transient nature of MCs.
Methodology, status and plans for development and assessment of Cathare code
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bestion, D.; Barre, F.; Faydide, B.
1997-07-01
This paper presents the methodology, status and plans for the development, assessment and uncertainty evaluation of the Cathare code. Cathare is a thermalhydraulic code developed by CEA (DRN), IPSN, EDF and FRAMATOME for PWR safety analysis. First, the status of the code development and assessment is presented. The general strategy used for the development and the assessment of the code is presented. Analytical experiments with separate effect tests, and component tests are used for the development and the validation of closure laws. Successive Revisions of constitutive laws are implemented in successive Versions of the code and assessed. System tests ormore » integral tests are used to validate the general consistency of the Revision. Each delivery of a code Version + Revision is fully assessed and documented. A methodology is being developed to determine the uncertainty on all constitutive laws of the code using calculations of many analytical tests and applying the Discrete Adjoint Sensitivity Method (DASM). At last, the plans for the future developments of the code are presented. They concern the optimization of the code performance through parallel computing - the code will be used for real time full scope plant simulators - the coupling with many other codes (neutronic codes, severe accident codes), the application of the code for containment thermalhydraulics. Also, physical improvements are required in the field of low pressure transients and in the modeling for the 3-D model.« less
Revised associative inference paradigm confirms relational memory impairment in schizophrenia
Armstrong, Kristan; Williams, Lisa E.; Heckers, Stephan
2013-01-01
Objective Patients with schizophrenia have widespread cognitive impairments, with selective deficits in relational memory. We previously reported a differential relational memory deficit in schizophrenia using the Associative Inference Paradigm (AIP), a task suggested by the Cognitive Neuroscience Treatment Research to Improve Cognition in Schizophrenia (CNTRICS) initiative to examine relational memory. However, the AIP had limited feasibility for testing in schizophrenia due to high attrition of schizophrenia patients during training. Here we developed and tested a revised version of the AIP to improve feasibility. Method 30 healthy control and 37 schizophrenia subjects received 3 study-test sessions on 3 sets of paired associates: H-F1 (house paired with face), H-F2 (same house paired with new face), and F3-F4 (two novel faces). After training, subjects were tested on the trained, non-inferential Face-Face pairs (F3-F4) and novel, inferential Face-Face pairs (F1-F2), constructed from the faces of the trained House-Face pairs. Results Schizophrenia patients were significantly more impaired on the inferential F1-F2 pairs than the non-inferential F3-F4 pairs, providing evidence for a differential relational memory deficit. Only 8 percent of schizophrenia patients were excluded from testing due to poor training performance. Conclusions The revised AIP confirmed the previous finding of a relational memory deficit in a larger and more representative sample of schizophrenia patients. PMID:22612578
Revised associative inference paradigm confirms relational memory impairment in schizophrenia.
Armstrong, Kristan; Williams, Lisa E; Heckers, Stephan
2012-07-01
Patients with schizophrenia have widespread cognitive impairments, with selective deficits in relational memory. We previously reported a differential relational memory deficit in schizophrenia using the Associative Inference Paradigm (AIP), a task suggested by the Cognitive Neuroscience Treatment Research to Improve Cognition in Schizophrenia (CNTRICS) initiative to examine relational memory. However, the AIP had limited feasibility for testing in schizophrenia because of high attrition of schizophrenia patients during training. Here we developed and tested a revised version of the AIP to improve feasibility. 30 healthy control and 37 schizophrenia subjects received 3 study-test sessions on 3 sets of paired associates: H-F1 (house paired with face), H-F2 (same house paired with new face), and F3-F4 (two novel faces). After training, subjects were tested on the trained, noninferential Face-Face pairs (F3-F4) and novel, inferential Face-Face pairs (F1-F2), constructed from the faces of the trained House-Face pairs. Schizophrenia patients were significantly more impaired on the inferential F1-F2 pairs than the noninferential F3-F4 pairs, providing evidence for a differential relational memory deficit. Only 8% of schizophrenia patients were excluded from testing because of poor training performance. The revised AIP confirmed the previous finding of a relational memory deficit in a larger and more representative sample of schizophrenia patients.
The Variation Test and Extraction Equipment to Optimum Asphalt by Using Gasoline Solvent
NASA Astrophysics Data System (ADS)
Soehardi, Fitridawati
2017-12-01
Based on the Binamarga Specification 2010 at third revision, the extraction test should be carried out using the specimen from the loose asphalt mixture extracted from the back of the finisher bitumen machine. The purpose of this research is to find out the result of pretest and posttest extraction asphalt content. The Extraction test using two equipment, they are Soklet and Centrifuge. The specimens was used AMP, Asphalt Finisher and Core, which involved gasoline solvent. Based on the asphalt level extraction test results, the appropriate equipment was used centrifuge with the level accuracy as requirement of Binamarga Specification 2010 at third revision and the level of ease used as equipment in the field study. The asphalt content obtained for AMP 5,51%, Asphalt Finisher5,46% and Core 5.34%. As for the socket asphalt content obtained is AMP 5.55%, Asphalt Finisher 5.50% and Core core 5. 41%. The extract test value of asphalt content decreased, so it can be formulated KA JMF
DOE Office of Scientific and Technical Information (OSTI.GOV)
Han, Ji-Young; Hong, Song-You; Sunny Lim, Kyo-Sun
The sensitivity of a cumulus parameterization scheme (CPS) to a representation of precipitation production is examined. To do this, the parameter that determines the fraction of cloud condensate converted to precipitation in the simplified Arakawa–Schubert (SAS) convection scheme is modified following the results from a cloud-resolving simulation. While the original conversion parameter is assumed to be constant, the revised parameter includes a temperature dependency above the freezing level, whichleadstolessproductionoffrozenprecipitating condensate with height. The revised CPS has been evaluated for a heavy rainfall event over Korea as well as medium-range forecasts using the Global/Regional Integrated Model system (GRIMs). The inefficient conversionmore » of cloud condensate to convective precipitation at colder temperatures generally leads to a decrease in pre-cipitation, especially in the category of heavy rainfall. The resultant increase of detrained moisture induces moistening and cooling at the top of clouds. A statistical evaluation of the medium-range forecasts with the revised precipitation conversion parameter shows an overall improvement of the forecast skill in precipitation and large-scale fields, indicating importance of more realistic representation of microphysical processes in CPSs.« less