Sample records for test re-test reliability

  1. Test-re-test reliability and inter-rater reliability of a digital pelvic inclinometer in young, healthy males and females.

    PubMed

    Beardsley, Chris; Egerton, Tim; Skinner, Brendon

    2016-01-01

    Objective. The purpose of this study was to investigate the reliability of a digital pelvic inclinometer (DPI) for measuring sagittal plane pelvic tilt in 18 young, healthy males and females. Method. The inter-rater reliability and test-re-test reliabilities of the DPI for measuring pelvic tilt in standing on both the right and left sides of the pelvis were measured by two raters carrying out two rating sessions of the same subjects, three weeks apart. Results. For measuring pelvic tilt, inter-rater reliability was designated as good on both sides (ICC = 0.81-0.88), test-re-test reliability within a single rating session was designated as good on both sides (ICC = 0.88-0.95), and test-re-test reliability between two rating sessions was designated as moderate on the left side (ICC = 0.65) and good on the right side (ICC = 0.85). Conclusion. Inter-rater reliability and test-re-test reliability within a single rating session of the DPI in measuring pelvic tilt were both good, while test-re-test reliability between rating sessions was moderate-to-good. Caution is required regarding the interpretation of the test-re-test reliability within a single rating session, as the raters were not blinded. Further research is required to establish validity.

  2. Reliability of the Community Balance and Mobility Scale (CB&M) in high-functioning school-aged children and adolescents who have an acquired brain injury.

    PubMed

    Wright, F Virginia; Ryan, Jennifer; Brewer, Kelly

    2010-01-01

    To examine inter-rater, intra-rater and test-re-test reliability of the Community Balance and Mobility Scale (CB&M) and compare reliability in live vs videotape rating contexts for children with acquired brain injury (ABI). Repeated measures design. Seven physiotherapists (PTs) were trained as assessors. The primary assessor administered and scored baseline CB&M while the second assessor observed and scored independently (inter-rater reliability). Re-assessment occurred 3-10 days later by primary assessor (test-re-test reliability). Assessments were videotaped. There were 32 participants with ABI (mean age = 14 years 1 month (SD = 2 years 1 month)). Baseline mean scores were 67.4% (18.2) and 66.7% (18.3) for primary and second assessor, respectively. Primary assessors' re-test mean score was 69.3%. Inter-rater reliability ICC was 0.93 (95% confidence interval (CI) = 0.87-0.97). Test-re-test ICC was 0.90 (95%CI = 0.81-0.95) and Bland-Altman plot indicated greatest test-re-test differences for mid-range CB&M scores. Minimum detectable change (MDC₉₀) was 13.5% points. The CB&M showed excellent reliability in youth. Reliability was comparable for live and videotape rating approaches, meaning that the easier and less expensive live-rating can be recommended. Future work should focus on evaluation of responsiveness to change in rehabilitation centre and community intervention contexts.

  3. Test-retest reliability of the eating disorder examination-questionnaire (EDE-Q) in a college sample

    PubMed Central

    2013-01-01

    Background The Eating Disorder Examination-Questionnaire (EDE-Q), a widely used self-report instrument, is often used for measuring change in eating disorder symptoms over the course of treatment. However, limited data exist about test-retest reliability, particularly for men. The current study evaluated EDE-Q 7-day test-retest reliability in male (n = 47) and female (n = 44) undergraduate students together and separately by gender. Results Internal consistency was consistently higher for women and at Time 2, but remained acceptable for both men and women at both time points. Cronbach’s α ranged from .75 (Restraint at Time 1) to .93 (Shape Concern at Time 2) for women and from .73 (Eating Concern at Time 2) to .89 (Shape Concern at Time 2) for men. With the exception of some of the eating disorder behaviors, test re-test reliability was fairly strong for both men and women. Shape Concern and the global EDE-Q score were highest for both men and women (Spearman’s rho > 0.89 with the exception of Shape Concern for women for which Spearman’s rho = .86). Test re-test reliability was lower for the eating disorder behavior measures, particularly for men, for whom Kendall’s tau-b for frequency and phi for occurrence was less than 0.70 for all but objective bulimic episodes. Conclusions Results were consistent with past research for women, indicating strong test re-test reliability in attitudinal features of eating disorders, but lower test re-test reliability in behavioral features. Internal consistency and test re-test reliability was good for the attitudinal features of eating disorder in men, but tended to be lower for men compared to women. The EDE-Q appears to be a reliable instrument for assessing eating disorder attitudes in both male and female undergraduate students, but is less reliable for assessing ED behaviors, particularly in men. PMID:24999420

  4. [The appraisal of reliability and validity of subjective workload assessment technique and NASA-task load index].

    PubMed

    Xiao, Yuan-mei; Wang, Zhi-ming; Wang, Mian-zhen; Lan, Ya-jia

    2005-06-01

    To test the reliability and validity of two mental workload assessment scales, i.e. subjective workload assessment technique (SWAT) and NASA task load index (NASA-TLX). One thousand two hundred and sixty-eight mental workers were sampled from various kinds of occupations, such as scientific research, education, administration and medicine, etc, with randomized cluster sampling. The re-test reliability, split-half reliability, Cronbach's alpha coefficient and correlation coefficients between item score and total score were adopted to test the reliability. The test of validity included structure validity. The re-test reliability coefficients of these two scales and their items were ranged from 0.516 to 0.753 (P < 0.01), indicating the two scales had good re-test reliability; the split-half reliability of SWAT was 0.645, and its Cronbach's alpha coefficient was more than 0.80, all the correlation coefficients between its items score and total score were more than 0.70; as for NASA-TLX, both the split-half reliability and Cronbach's alpha coefficient were more than 0.80, the correlation coefficients between its items score and total score were all more than 0.60 (P < 0.01) except the item of performance. Both scales had good inner consistency. The Pearson correlation coefficient between the two scales was 0.492 (P < 0.01), implying the results of the two scales had good consistency. Factor analysis showed that the two scales had good structure validity. Both SWAT and NASA-TLX have good reliability and validity and may be used as a valid tool to assess mental workload in China after being revised properly.

  5. External Validation and Evaluation of Reliability and Validity of the Modified Seoul National University Renal Stone Complexity Scoring System to Predict Stone-Free Status After Retrograde Intrarenal Surgery.

    PubMed

    Park, Juhyun; Kang, Minyong; Jeong, Chang Wook; Oh, Sohee; Lee, Jeong Woo; Lee, Seung Bae; Son, Hwancheol; Jeong, Hyeon; Cho, Sung Yong

    2015-08-01

    The modified Seoul National University Renal Stone Complexity scoring system (S-ReSC-R) for retrograde intrarenal surgery (RIRS) was developed as a tool to predict stone-free rate (SFR) after RIRS. We externally validated the S-ReSC-R. We retrospectively reviewed 159 patients who underwent RIRS. The S-ReSC-R was assigned from 1 to 12 according to the location and number of sites involved. The stone-free status was defined as no evidence of a stone or with clinically insignificant residual fragment stones less than 2 mm. Interobserver and test-retest reliabilities were evaluated. Statistical performance of the prediction model was assessed by its predictive accuracy, predictive probability, and clinical usefulness. Overall SFR was 73.0%. The SFRs were 86.7%, 70.2%, and 48.6% in low-score (1-2), intermediate-score (3-4), and high-score (5-12) groups, respectively (p<0.001). External validation of S-ReSC-R revealed an area under the curve (AUC) of 0.731 (95% CI 0.650-0.813). The AUC of the three-titered S-ReSC-R was 0.701 (95% CI 0.609-0.794). The calibration plot showed that the predicted probability of SFR had a concordance comparable to that of observed frequency. The Hosmer-Lemeshow goodness of fit test revealed a p-value of 0.01 for the S-ReSC-R and 0.90 for the three-titered S-ReSC-R. Interobserver and test-retest reliabilities revealed an almost perfect level of agreement. The present study proved the predictive value of S-ReSC-R to predict SFR following RIRS in an independent cohort. Interobserver and test-retest reliabilities confirmed that S-ReSC-R was reliable and valid.

  6. Questionnaire for low back pain in the garment industry workers

    PubMed Central

    Bindra, Supreet; Sinha, A. G. K.; Benjamin, A. I.

    2013-01-01

    Low back pain affects up to 90% of the world's population at some point in their lives. Until date no questionnaire has been designed for back pain in the garment industry workers. Therefore, the objective of this study is to design a questionnaire to determine the prevalence, risk factors, impact, health care service utilization and back pain features in the garment industry workers and gain preliminary experience of its use. The content validity and reliability of the questionnaire was established. Items showing acceptable internal consistency and moderate to high test re-test reliability were retained in the questionnaire. Items showing unacceptable internal consistency, low test re-test reliability or poor differentiation were reworded, redrafted and re-tested on the workers. It took 20 min to complete one interview schedule. Environmental factors such as the absence of the garment industry owner/supervisor or co-workers at the time of the interview and interview during leisure hours need to be standardized. Thus, final questionnaire is ready for use after necessary amendments and will be used on the larger sample size in the main study. PMID:24421591

  7. Questionnaire for low back pain in the garment industry workers.

    PubMed

    Bindra, Supreet; Sinha, A G K; Benjamin, A I

    2013-05-01

    Low back pain affects up to 90% of the world's population at some point in their lives. Until date no questionnaire has been designed for back pain in the garment industry workers. Therefore, the objective of this study is to design a questionnaire to determine the prevalence, risk factors, impact, health care service utilization and back pain features in the garment industry workers and gain preliminary experience of its use. The content validity and reliability of the questionnaire was established. Items showing acceptable internal consistency and moderate to high test re-test reliability were retained in the questionnaire. Items showing unacceptable internal consistency, low test re-test reliability or poor differentiation were reworded, redrafted and re-tested on the workers. It took 20 min to complete one interview schedule. Environmental factors such as the absence of the garment industry owner/supervisor or co-workers at the time of the interview and interview during leisure hours need to be standardized. Thus, final questionnaire is ready for use after necessary amendments and will be used on the larger sample size in the main study.

  8. Measuring Quadriceps strength in adults with severe or moderate intellectual and visual disabilities: Feasibility and reliability.

    PubMed

    Dijkhuizen, Annemarie; Douma, Rob K; Krijnen, Wim P; van der Schans, Cees P; Waninge, Aly

    2018-05-30

    A feasible and reliable instrument to measure strength in persons with severe intellectual and visual disabilities (SIVD) is lacking. The aim of our study was to determine feasibility, learning period and reliability of three strength tests. Twenty-nine participants with SIVD performed the Minimum Sit-to-Stand Height test (MSST), the Leg Extension test (LE) and the 30 seconds Chair-Stand test (30sCS), once per week for 5 weeks. Feasibility was determined by the percentage of successful measurements; learning effect by using paired t test between two consecutive measurements; test-retest reliability by intraclass correlation coefficient and Limits of Agreement and, correlations by Pearson correlations. A sufficient feasibility and learning period of the tests was shown. The methods had sufficient test-retest reliability and moderate-to-sufficient correlations. The MSST, the LE, and the 30sCS are feasible tests for measuring muscle strength in persons with SIVD, having sufficient test re-test reliability. © 2018 John Wiley & Sons Ltd.

  9. Development and Validation of an HIV Risk Exposure and Indicator Conditions Questionnaire to Support Targeted HIV Screening.

    PubMed

    Elías, María Jesús Pérez; Gómez-Ayerbe, Cristina; Elías, Pilar Pérez; Muriel, Alfonso; de Santiago, Alberto Diaz; Martinez-Colubi, María; Moreno, Ana; Santos, Cristina; Polo, Lidia; Barea, Rafa; Robledillo, Gema; Uranga, Almudena; Espín, Agustina Cano; Quereda, Carmen; Dronda, Fernando; Casado, Jose Luis; Moreno, Santiago

    2016-02-01

    The aim of our study was to develop a Spanish-structured HIV risk of exposure and indicator conditions (RE&IC) questionnaire. People attending to an emergency room or to a primary clinical care center were offered to participate in a prospective, 1 arm, open label study, in which all enrolled patients filled out our developed questionnaire and were HIV tested. Questionnaire accuracy, feasibility, and reliability were evaluated.Valid paired 5329 HIV RE&IC questionnaire and rapid HIV tests were performed, 69.3% in the primary clinical care center, 49.6% women, median age 37 years old, 74.9% Spaniards, 20.1% Latin-Americans. Confirmed hidden HIV infection was detected in 4.1%, while HIV RE&IC questionnaire was positive in 51.2%. HIV RE&IC questionnaire sensitivity was 100% to predict HIV infection, with a 100% negative predictive value. When considered separately, RE or IC items sensitivity decreases to 86.4% or 91%, and similarly their negative predictive value to 99.9% for both of them. The majority of people studied, 90.8% self-completed HIV RE&IC questionnaire. Median time to complete was 3 minutes. Overall HIV RE&IC questionnaire test-retest Kappa agreement was 0.82 (almost perfect), likewise for IC items 0.89, while for RE items was lower 0.78 (substantial).A feasible and reliable Spanish HIV RE&IC self questionnaire accurately discriminated all non-HIV-infected people without missing any HIV diagnoses, in a low prevalence HIV infection area. The best accuracy and reliability were obtained when combining HIV RE&IC items.

  10. Development and Validation of an HIV Risk Exposure and Indicator Conditions Questionnaire to Support Targeted HIV Screening

    PubMed Central

    Elías, María Jesús Pérez; Gómez-Ayerbe, Cristina; Elías, Pilar Pérez; Muriel, Alfonso; de Santiago, Alberto Diaz; Martinez-Colubi, María; Moreno, Ana; Santos, Cristina; Polo, Lidia; Barea, Rafa; Robledillo, Gema; Uranga, Almudena; Espín, Agustina Cano; Quereda, Carmen; Dronda, Fernando; Casado, Jose Luis; Moreno, Santiago

    2016-01-01

    Abstract The aim of our study was to develop a Spanish-structured HIV risk of exposure and indicator conditions (RE&IC) questionnaire. People attending to an emergency room or to a primary clinical care center were offered to participate in a prospective, 1 arm, open label study, in which all enrolled patients filled out our developed questionnaire and were HIV tested. Questionnaire accuracy, feasibility, and reliability were evaluated. Valid paired 5329 HIV RE&IC questionnaire and rapid HIV tests were performed, 69.3% in the primary clinical care center, 49.6% women, median age 37 years old, 74.9% Spaniards, 20.1% Latin-Americans. Confirmed hidden HIV infection was detected in 4.1%, while HIV RE&IC questionnaire was positive in 51.2%. HIV RE&IC questionnaire sensitivity was 100% to predict HIV infection, with a 100% negative predictive value. When considered separately, RE or IC items sensitivity decreases to 86.4% or 91%, and similarly their negative predictive value to 99.9% for both of them. The majority of people studied, 90.8% self-completed HIV RE&IC questionnaire. Median time to complete was 3 minutes. Overall HIV RE&IC questionnaire test-retest Kappa agreement was 0.82 (almost perfect), likewise for IC items 0.89, while for RE items was lower 0.78 (substantial). A feasible and reliable Spanish HIV RE&IC self questionnaire accurately discriminated all non–HIV-infected people without missing any HIV diagnoses, in a low prevalence HIV infection area. The best accuracy and reliability were obtained when combining HIV RE&IC items. PMID:26844471

  11. 14 CFR 417.115 - Tests.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 4 2013-01-01 2013-01-01 false Tests. 417.115 Section 417.115 Aeronautics... TRANSPORTATION LICENSING LAUNCH SAFETY Launch Safety Responsibilities § 417.115 Tests. (a) General. All flight... re-testing necessary to ensure reliable operation. A launch operator must— (1) Coordinate test plans...

  12. 14 CFR 417.115 - Tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Tests. 417.115 Section 417.115 Aeronautics... TRANSPORTATION LICENSING LAUNCH SAFETY Launch Safety Responsibilities § 417.115 Tests. (a) General. All flight... re-testing necessary to ensure reliable operation. A launch operator must— (1) Coordinate test plans...

  13. 14 CFR 417.115 - Tests.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 4 2011-01-01 2011-01-01 false Tests. 417.115 Section 417.115 Aeronautics... TRANSPORTATION LICENSING LAUNCH SAFETY Launch Safety Responsibilities § 417.115 Tests. (a) General. All flight... re-testing necessary to ensure reliable operation. A launch operator must— (1) Coordinate test plans...

  14. 14 CFR 417.115 - Tests.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 4 2014-01-01 2014-01-01 false Tests. 417.115 Section 417.115 Aeronautics... TRANSPORTATION LICENSING LAUNCH SAFETY Launch Safety Responsibilities § 417.115 Tests. (a) General. All flight... re-testing necessary to ensure reliable operation. A launch operator must— (1) Coordinate test plans...

  15. 14 CFR 417.115 - Tests.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 4 2012-01-01 2012-01-01 false Tests. 417.115 Section 417.115 Aeronautics... TRANSPORTATION LICENSING LAUNCH SAFETY Launch Safety Responsibilities § 417.115 Tests. (a) General. All flight... re-testing necessary to ensure reliable operation. A launch operator must— (1) Coordinate test plans...

  16. Perform qualify reliability-power tests by shooting common mistakes: practical problems and standard answers per Telcordia/Bellcore requests

    NASA Astrophysics Data System (ADS)

    Yu, Zheng

    2002-08-01

    Facing the new demands of the optical fiber communications market, almost all the performance and reliability of optical network system are dependent on the qualification of the fiber optics components. So, how to comply with the system requirements, the Telcordia / Bellcore reliability and high-power testing has become the key issue for the fiber optics components manufacturers. The qualification of Telcordia / Bellcore reliability or high-power testing is a crucial issue for the manufacturers. It is relating to who is the outstanding one in the intense competition market. These testing also need maintenances and optimizations. Now, work on the reliability and high-power testing have become the new demands in the market. The way is needed to get the 'Triple-Win' goal expected by the component-makers, the reliability-testers and the system-users. To those who are meeting practical problems for the testing, there are following seven topics that deal with how to shoot the common mistakes to perform qualify reliability and high-power testing: ¸ Qualification maintenance requirements for the reliability testing ¸ Lots control for preparing the reliability testing ¸ Sampling select per the reliability testing ¸ Interim measurements during the reliability testing ¸ Basic referencing factors relating to the high-power testing ¸ Necessity of re-qualification testing for the changing of producing ¸ Understanding the similarity for product family by the definitions

  17. Intra and Inter-Rater Reliability of Screening for Movement Impairments: Movement Control Tests from The Foundation Matrix

    PubMed Central

    Mischiati, Carolina R.; Comerford, Mark; Gosford, Emma; Swart, Jacqueline; Ewings, Sean; Botha, Nadine; Stokes, Maria; Mottram, Sarah L.

    2015-01-01

    Pre-season screening is well established within the sporting arena, and aims to enhance performance and reduce injury risk. With the increasing need to identify potential injury with greater accuracy, a new risk assessment process has been produced; The Performance Matrix (battery of movement control tests). As with any new method of objective testing, it is fundamental to establish whether the same results can be reproduced between examiners and by the same examiner on consecutive occasions. This study aimed to determine the intra-rater test re-test and inter-rater reliability of tests from a component of The Performance Matrix, The Foundation Matrix. Twenty participants were screened by two experienced musculoskeletal therapists using nine tests to assess the ability to control movement during specific tasks. Movement evaluation criteria for each test were rated as pass or fail. The therapists observed participants real-time and tests were recorded on video to enable repeated ratings four months later to examine intra-rater reliability (videos rated two weeks apart). Overall test percentage agreement was 87% for inter-rater reliability; 98% Rater 1, 94% Rater 2 for test re-test reliability; and 75% for real-time versus video. Intraclass-correlation coefficients (ICCs) were excellent between raters (0.81) and within raters (Rater 1, 0.96; Rater 2, 0.88) but poor for real-time versus video (0.23). Reliability for individual components of each test was more variable: inter-rater, 68-100%; intra-rater, 88-100% Rater 1, 75-100% Rater 2; and real-time versus video 31-100%. Cohen’s Kappa values for inter-rater reliability were 0.0-1.0; intra-rater 0.6-1.0 for Rater 1; -0.1-1.0 for Rater 2; and -0.1-1 for real-time versus video. It is concluded that both inter and intra-rater reliability of tests in The Foundation Matrix are acceptable when rated by experienced therapists. Recommendations are made for modifying some of the criteria to improve reliability where excellence was not reached. Key points The movement control tests of The Foundation Matrix had acceptable reliability between raters and within raters on different days Agreement between observations made on tests performed real-time and on video recordings was low, indicating poor validity of use of video recordings Some movement evaluation criteria related to specific tests that did not achieve excellent agreement could be modified to improve reliability PMID:25983594

  18. Feasibility of surveillance of changes in human fertility and semen quality.

    PubMed

    Stewart, T M; Brown, E H; Venn, A; Mbizvo, M T; Farley, T M; Garrett, C; Baker, H W

    2001-01-01

    There is concern that male fertility is declining, but this is difficult to study because few men volunteer for studies of semen quality, and recruitment bias may over-represent the subfertile. The Human Reproduction Programme of the World Health Organization developed a protocol for multicentre studies of fertility involving a questionnaire for pregnant women to obtain time to pregnancy (TTP): the number of menstrual cycles taken to conceive. Male characteristics and semen quality will be determined in a subset of the partners. Our aim was to validate the TTP questionnaire, and to examine potential recruitment bias and feasibility of conducting large-scale surveillance of fertility. The questionnaire was administered to 120 pregnant women (16-32 weeks). Validation included internal reliability by consistency of responses, test-re-test reliability by repeat administration (20 women) and accuracy by comparison of gestational age from first antenatal ultrasound and menstrual dates. Internal reliability was high. Agreement between categorical responses on re-testing was very good (k > 0.8). In both the re-test and gestational age analysis, differences in TTP of 1 cycle were found (standard deviation <0.25 cycles). In this small pilot study there was no evidence of recruitment bias. Response rates indicate the feasibility of surveillance of fertility in large maternity centres.

  19. [Turkish validity and reliability study of fear of pain questionnaire-III].

    PubMed

    Ünver, Seher; Turan, Fatma Nesrin

    2018-01-01

    This study aimed to develop a Turkish version of the Fear of Pain Questionnaire-III developed by McNeil and Rainwater (1998) and examine its validity and reliability indicators. The study was conducted with 459 university students studying in the nursing department. The Turkish translation of the scale was conducted by language experts and the original scale owner. Expert opinions were taken for language validity, and the Lawshe's content validity ratio formula was used to calculate the content validity. Exploratory factor analysis was used to assess the construct validity. The factors were rotated using the Varimax rotation (orthogonal) method. For reliability indicators of the questionnaire, the internal consistency coefficient and test re-test reliability were utilized. Explanatory factor analyses using the three-factor model (explaining 50.5% of the total variance) revealed that the item factor loads varied were above the limit value of 0.30 which indicated that the questionnaire had good construct validity. The Cronbach's alpha value for the total questionnaire was 0.938, and test re-test value was 0.846 for the total scale. The Turkish version of the Fear of Pain Questionnaire-III had sufficiently high reliability and validity to be used as a tool in evaluating the fear of pain among the young Turkish population.

  20. MEASURING SPORT-SPECIFIC PHYSICAL ABILITIES IN MALE GYMNASTS: THE MEN'S GYMNASTICS FUNCTIONAL MEASUREMENT TOOL.

    PubMed

    Sleeper, Mark D; Kenyon, Lisa K; Elliott, James M; Cheng, M Samuel

    2016-12-01

    Despite the availability of various field-tests for many competitive sports, a reliable and valid test specifically developed for use in men's gymnastics has not yet been developed. The Men's Gymnastics Functional Measurement Tool (MGFMT) was designed to assess sport-specific physical abilities in male competitive gymnasts. The purpose of this study was to develop the MGFMT by establishing a scoring system for individual test items and to initiate the process of establishing test-retest reliability and construct validity. A total of 83 competitive male gymnasts ages 7-18 underwent testing using the MGFMT. Thirty of these subjects underwent re-testing one week later in order to assess test-retest reliability. Construct validity was assessed using a simple regression analysis between total MGFMT scores and the gymnasts' USA-Gymnastics competitive level to calculate the coefficient of determination (r 2 ). Test-retest reliability was analyzed using Model 1 Intraclass correlation coefficients (ICC). Statistical significance was set at the p<0.05 level. The relationship between total MGFMT scores and subjects' current USA-Gymnastics competitive level was found to be good (r 2  = 0.63). Reliability testing of the MGFMT composite test score showed excellent test-retest reliability over a one-week period (ICC = 0.97). Test-retest reliability of the individual component tests ranged from good to excellent (ICC = 0.75-0.97). The results of this study provide initial support for the construct validity and test-retest reliability of the MGFMT. Level 3.

  1. Stroke and aphasia quality-of-life scale-39: Reliability and validity of the Turkish version.

    PubMed

    Noyan-ErbaŞ, AyŞin; Toğram, Bülent

    2016-10-01

    The aim of this study was to adapt the stroke and aphasia quality-of-life scale-39 (SAQoL-39) to the Turkish language and carry out a reliability and validity study of the instrument in a group of patients with aphasia. The study was a descriptive study and contained three phases: adaptation of the SAQoL-39 to the Turkish language, administration of the scale to 30 aphasia patients and reliability and validity studies of the scale. Internal consistency was assessed with Cronbach's alpha and test-re-test reliability was explored (n = 14). The adaptation process was completed based on inter-rater agreement on the translated items and within the scope of final editing by the authors of the study. The SAQoL-39 in Turkish exhibited high test-re-test reliability (ICC =0.97) as well as acceptability with minimal missing data (0-1.4). This instrument exhibited high internal consistency (Cronbach's α = 0.70-0.97), domain-total correlations (r = 0.76-0.85) and inter-domain correlations (r = 0.40-0.68). The analysis shows that the Turkish version of SAQoL-39 is a scale that is highly acceptable, valid and reliable and can be easily used in evaluating the quality-of-life of Turkish people with aphasia.

  2. Test Re-Test Reliability of Four Versions of the 3-Cone Test in Non-Athletic Men

    PubMed Central

    Langley, Jason G.; Chetlin, Robert D.

    2017-01-01

    Until recently, measurement and evaluation in sport science, especially agility testing, has not always included key elements of proper test construction. Often tests are published without reporting reliability and validity analysis for a specific population. The purpose of the present study was to examine the test re-test reliability of four versions of the 3-Cone Test (3CT), and provide guidance on proper test construction for testing agility in athletic populations. Forty male students enrolled in classes in the Department of Physical Education at a mid-Atlantic university participated. On each of test day participants performed 10 trials. In random order, they performed three trials to the right (3CTR, standard test), three to the left (3CTL), and two modified trials (3CTAR and 3CTAL), which included a reactive component in which a visual cue was given to indicate direction. Intra-class correlation coefficients (ICC) indicated a moderate to high reliability for the four tests, 3CTR 0.79 (0.64-0.88, 95%CI), 3CTL 0.73 (0.55-0.85), 3CTAR 0.85(0.74-0.92), and 3CTAL 0.79 (0.64-0.88). Small standard error of the measurement (SEM) was found; range 0.09 to 0.10. Pearson correlations between tests were high (0.82-0.92) on day one as well as day two (0.72-0.85). These results indicate each version of the 3-Cone Test is reliable; however, further tests are needed with specific athletic populations. Only the 3CTAR and 3CTAL are tests of agility due to the inclusion of a reactive component. Future studies examining agility testing and training should incorporate technological elements, including automated timing systems and motion capture analysis. Such instrumentation will allow for optimal design of tests that simulate sport-specific game conditions. Key points The commonly used 3-cone test (upside down “L” to the right”) is a reliable change of direction speed (CODS) test when evaluating collegiate males. A modification of the CODS 3-cone test (upside down “L” to the left instead of to the right) is also reliable for evaluating collegiate males. A modification of the 3-cone that includes reaction and a choice of a cut to the left or right remains reliable as now an agility test version in collegiate males. There are moderate to high correlation between the 4 versions of the tests. Reaction remains a critical to the design of testing and training agility protocols, and should be investigated similarly to various athletes including novice/expert, male/female, and nearly every sporting event. PMID:28344450

  3. Hypertension Knowledge-Level Scale (HK-LS): a study on development, validity and reliability.

    PubMed

    Erkoc, Sultan Baliz; Isikli, Burhanettin; Metintas, Selma; Kalyoncu, Cemalettin

    2012-03-01

    This study was conducted to develop a scale to measure knowledge about hypertension among Turkish adults. The Hypertension Knowledge-Level Scale (HK-LS) was generated based on content, face, and construct validity, internal consistency, test re-test reliability, and discriminative validity procedures. The final scale had 22 items with six sub-dimensions. The scale was applied to 457 individuals aged ≥ 18 years, and 414 of them were re-evaluated for test-retest reliability. The six sub-dimensions encompassed 60.3% of the total variance. Cronbach alpha coefficients were 0.82 for the entire scale and 0.92, 0.59, 0.67, 0.77, 0.72, and 0.76 for the sub-dimensions of definition, medical treatment, drug compliance, lifestyle, diet, and complications, respectively. The scale ensured internal consistency in reliability and construct validity, as well as stability over time. Significant relationships were found between knowledge score and age, gender, educational level, and history of hypertension of the participants. No correlation was found between knowledge score and working at an income-generating job. The present scale, developed to measure the knowledge level of hypertension among Turkish adults, was found to be valid and reliable.

  4. MEASURING SPORT-SPECIFIC PHYSICAL ABILITIES IN MALE GYMNASTS: THE MEN'S GYMNASTICS FUNCTIONAL MEASUREMENT TOOL

    PubMed Central

    Kenyon, Lisa K.; Elliott, James M; Cheng, M. Samuel

    2016-01-01

    Purpose/Background Despite the availability of various field-tests for many competitive sports, a reliable and valid test specifically developed for use in men's gymnastics has not yet been developed. The Men's Gymnastics Functional Measurement Tool (MGFMT) was designed to assess sport-specific physical abilities in male competitive gymnasts. The purpose of this study was to develop the MGFMT by establishing a scoring system for individual test items and to initiate the process of establishing test-retest reliability and construct validity. Methods A total of 83 competitive male gymnasts ages 7-18 underwent testing using the MGFMT. Thirty of these subjects underwent re-testing one week later in order to assess test-retest reliability. Construct validity was assessed using a simple regression analysis between total MGFMT scores and the gymnasts’ USA-Gymnastics competitive level to calculate the coefficient of determination (r2). Test-retest reliability was analyzed using Model 1 Intraclass correlation coefficients (ICC). Statistical significance was set at the p<0.05 level. Results The relationship between total MGFMT scores and subjects’ current USA-Gymnastics competitive level was found to be good (r2 = 0.63). Reliability testing of the MGFMT composite test score showed excellent test-retest reliability over a one-week period (ICC = 0.97). Test-retest reliability of the individual component tests ranged from good to excellent (ICC = 0.75-0.97). Conclusions The results of this study provide initial support for the construct validity and test-retest reliability of the MGFMT. Level of Evidence Level 3 PMID:27999723

  5. Toward reliable characterization of functional homogeneity in the human brain: preprocessing, scan duration, imaging resolution and computational space.

    PubMed

    Zuo, Xi-Nian; Xu, Ting; Jiang, Lili; Yang, Zhi; Cao, Xiao-Yan; He, Yong; Zang, Yu-Feng; Castellanos, F Xavier; Milham, Michael P

    2013-01-15

    While researchers have extensively characterized functional connectivity between brain regions, the characterization of functional homogeneity within a region of the brain connectome is in early stages of development. Several functional homogeneity measures were proposed previously, among which regional homogeneity (ReHo) was most widely used as a measure to characterize functional homogeneity of resting state fMRI (R-fMRI) signals within a small region (Zang et al., 2004). Despite a burgeoning literature on ReHo in the field of neuroimaging brain disorders, its test-retest (TRT) reliability remains unestablished. Using two sets of public R-fMRI TRT data, we systematically evaluated the ReHo's TRT reliability and further investigated the various factors influencing its reliability and found: 1) nuisance (head motion, white matter, and cerebrospinal fluid) correction of R-fMRI time series can significantly improve the TRT reliability of ReHo while additional removal of global brain signal reduces its reliability, 2) spatial smoothing of R-fMRI time series artificially enhances ReHo intensity and influences its reliability, 3) surface-based R-fMRI computation largely improves the TRT reliability of ReHo, 4) a scan duration of 5 min can achieve reliable estimates of ReHo, and 5) fast sampling rates of R-fMRI dramatically increase the reliability of ReHo. Inspired by these findings and seeking a highly reliable approach to exploratory analysis of the human functional connectome, we established an R-fMRI pipeline to conduct ReHo computations in both 3-dimensions (volume) and 2-dimensions (surface). Copyright © 2012 Elsevier Inc. All rights reserved.

  6. Feasibility Study on Determining the Effect of Testing on Harpoon Missile System Reliability.

    DTIC Science & Technology

    1985-06-01

    or subassem- blies) failed and the date. Correlation between test date and calendar age is achieved by inservice date. Failure events are keyed to...acceptance test of the guidance section is used as the inservice event. ETH time recorded for each test is a cumulative time except for re-zeroing in...and testing environ- ments. The inservice date would correspond to the beginning of the retrieved test history at the final acceptance test of the

  7. Extended version of the "Sniffin' Sticks" identification test: test-retest reliability and validity.

    PubMed

    Sorokowska, A; Albrecht, E; Haehner, A; Hummel, T

    2015-03-30

    The extended, 32-item version of the Sniffin' Sticks identification test was developed in order to create a precise tool enabling repeated, longitudinal testing of individual olfactory subfunctions. Odors of the previous test version had to be changed for technical reasons, and the odor identification test needed re-investigation in terms of reliability, validity, and normative values. In our study we investigated olfactory abilities of a group of 100 patients with olfactory dysfunction and 100 controls. We reconfirmed the high test-retest reliability of the extended version of the Sniffin' Sticks identification test and high correlations between the new and the original part of this tool. In addition, we confirmed the validity of the test as it discriminated clearly between controls and patients with olfactory loss. The additional set of 16 odor identification sticks can be either included in the current olfactory test, thus creating a more detailed diagnosis tool, or it can be used separately, enabling to follow olfactory function over time. Additionally, the normative values presented in our paper might provide useful guidelines for interpretation of the extended identification test results. The revised version of the Sniffin' Sticks 32-item odor identification test is a reliable and valid tool for the assessment of olfactory function. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Environmental and reliability test of FBG based geophone as geophysical exploration instrument

    NASA Astrophysics Data System (ADS)

    Zhang, Xiaolei; Min, Li; Li, Ming; Jiang, Shaodong; Zhang, Faxiang; Sun, Zhihui; Ni, Jiasheng; Peng, Gangding; Wang, Chang

    2017-10-01

    A fiber Bragg grating (FBG) based geophone is designed for low-frequency signal detection has high acceleration response of about 60 dB re pm/g in a low frequency range of 5 Hz 60 Hz. To Guarantee normal operation in field test and practical application, an acceleration amplitude restriction is added in the mechanical design of the FBG geophone. Then a series of environmental and reliability test have been proceeded with online or offline monitoring of its working performance, including high and low temperature test, vibration test, shock test and free drop test. All the tests are planned according to National standard or Oil & Gas Industry Standard. And the experimental results indicate that our FBG geophone meet the criterion of oil and gas industry product and is capable of field application.

  9. CONSISTENCY OF FIELD-BASED MEASURES OF NEUROMUSCULAR CONTROL USING FORCE PLATE DIAGNOSTICS IN ELITE MALE YOUTH SOCCER PLAYERS

    PubMed Central

    READ, PAUL; OLIVER, JON L.; DE STE CROIX, MARK B.A.; MYER, GREGORY D.; LLOYD, RHODRI S.

    2016-01-01

    Deficits in neuromuscular control during movement patterns such as landing are suggested pathomechanics that underlie sport-related injury. A common mode of assessment is measurement of landing forces during jumping tasks; however, these measures have been used less frequently in male youth soccer players and reliability data is sparse. The aim of this study was to examine the reliability of a field-based neuromuscular control screening battery using force plate diagnostics in this cohort. Twenty six pre-peak height velocity (PHV) and twenty five post-PHV elite male youth soccer players completed a drop vertical jump (DVJ), single leg 75% horizontal hop and stick (75%HOP) and single leg countermovement jump (SLCMJ). Measures of peak landing vertical ground reaction force (pVGRF), time to stabilisation (TTS), time to pVGRF, and pVGRF asymmetry were recorded. A test, re-test design was used and reliability statistics included: change in mean, intraclass correlation coefficient (ICC) and coefficient of variation (CV). No significant differences in mean score were reported for any of the assessed variables between test sessions. In both groups, pVGRF and asymmetry during the 75%HOP and SLCMJ demonstrated largely acceptable reliability (CV ≤ 10%). Greater variability was evident in DVJ pVGRF and all other assessed variables, across the three protocols (CV range = 13.8 – 49.7%). ICC values ranged from small to large and were generally higher in the post-PHV players. The results of this study suggest that pVGRF and asymmetry can be reliably assessed using a 75%HOP and SLCMJ in this cohort. These measures could be utilized to support a screening battery for elite male youth soccer players and for test re-test comparison. PMID:27075641

  10. Cross-cultural Adaptation of the "Functional Activities Questionnaire - FAQ" for use in Brazil

    PubMed Central

    Sanchez, Maria Angélica dos Santos; Correa, Pricila Cristina Ribeiro; Lourenço, Roberto Alves

    2011-01-01

    Objective The aim of this paper was to present the results of the first stage of cross-cultural adaptation of the Functional Activities Questionnaire (FAQ). Methods The tool was subjected to translation and re-translation, and the test-retest reliability of a proposed version for use in Brazil was analyzed. Results Of the 548 questionnaire respondents, a convenience sample of 68 informants was selected for retesting. Internal consistency was measured by Cronbach's alpha (0.95) while test-retest reliability was assessed using intra-class correlation (0.97). The findings have shown that FAQ is brief - averaging seven minutes to apply, easily understood and has good intra-rater test-retest reliability. Conclusion Our results suggest this adapted version of the FAQ is a reliable and stable tool which may be useful for assessing function in Brazilian elderly. Notwithstanding, the version should be subjected to further analysis with the aim of reaching functional equivalence. PMID:29213759

  11. Applications of computerized adaptive testing (CAT) to the assessment of headache impact.

    PubMed

    Ware, John E; Kosinski, Mark; Bjorner, Jakob B; Bayliss, Martha S; Batenhorst, Alice; Dahlöf, Carl G H; Tepper, Stewart; Dowson, Andrew

    2003-12-01

    To evaluate the feasibility of computerized adaptive testing (CAT) and the reliability and validity of CAT-based estimates of headache impact scores in comparison with 'static' surveys. Responses to the 54-item Headache Impact Test (HIT) were re-analyzed for recent headache sufferers (n = 1016) who completed telephone interviews during the National Survey of Headache Impact (NSHI). Item response theory (IRT) calibrations and the computerized dynamic health assessment (DYNHA) software were used to simulate CAT assessments by selecting the most informative items for each person and estimating impact scores according to pre-set precision standards (CAT-HIT). Results were compared with IRT estimates based on all items (total-HIT), computerized 6-item dynamic estimates (CAT-HIT-6), and a developmental version of a 'static' 6-item form (HIT-6-D). Analyses focused on: respondent burden (survey length and administration time), score distributions ('ceiling' and 'floor' effects), reliability and standard errors, and clinical validity (diagnosis, level of severity). A random sample (n = 245) was re-assessed to test responsiveness. A second study (n = 1103) compared actual CAT surveys and an improved 'static' HIT-6 among current headache sufferers sampled on the Internet. Respondents completed measures from the first study and the generic SF-8 Health Survey; some (n = 540) were re-tested on the Internet after 2 weeks. In the first study, simulated CAT-HIT and total-HIT scores were highly correlated (r = 0.92) without 'ceiling' or 'floor' effects and with a substantial reduction (90.8%) in respondent burden. Six of the 54 items accounted for the great majority of item administrations (3603/5028, 77.6%). CAT-HIT reliability estimates were very high (0.975-0.992) in the range where 95% of respondents scored, and relative validity (RV) coefficients were high for diagnosis (RV = 0.87) and severity (RV = 0.89); patient-level classifications were accurate 91.3% for a diagnosis of migraine. For all three criteria of change, CAT-HIT scores were more responsive than all other measures. In the second study, estimates of respondent burden, item usage, reliability and clinical validity were replicated. The test-retest reliability of CAT-HIT was 0.79 and alternate forms coefficients ranged from 0.85 to 0.91. All correlations with the generic SF-8 were negative. CAT-based administrations of headache impact items achieved very large reductions in respondent burden without compromising validity for purposes of patient screening or monitoring changes in headache impact over time. IRT models and CAT-based dynamic health assessments warrant testing among patients with other conditions.

  12. Reliability of Single-Leg Balance and Landing Tests in Rugby Union; Prospect of Using Postural Control to Monitor Fatigue.

    PubMed

    Troester, Jordan C; Jasmin, Jason G; Duffield, Rob

    2018-06-01

    The present study examined the inter-trial (within test) and inter-test (between test) reliability of single-leg balance and single-leg landing measures performed on a force plate in professional rugby union players using commercially available software (SpartaMARS, Menlo Park, USA). Twenty-four players undertook test - re-test measures on two occasions (7 days apart) on the first training day of two respective pre-season weeks following 48h rest and similar weekly training loads. Two 20s single-leg balance trials were performed on a force plate with eyes closed. Three single-leg landing trials were performed by jumping off two feet and landing on one foot in the middle of a force plate 1m from the starting position. Single-leg balance results demonstrated acceptable inter-trial reliability (ICC = 0.60-0.81, CV = 11-13%) for sway velocity, anterior-posterior sway velocity, and mediolateral sway velocity variables. Acceptable inter-test reliability (ICC = 0.61-0.89, CV = 7-13%) was evident for all variables except mediolateral sway velocity on the dominant leg (ICC = 0.41, CV = 15%). Single-leg landing results only demonstrated acceptable inter-trial reliability for force based measures of relative peak landing force and impulse (ICC = 0.54-0.72, CV = 9-15%). Inter-test results indicate improved reliability through the averaging of three trials with force based measures again demonstrating acceptable reliability (ICC = 0.58-0.71, CV = 7-14%). Of the variables investigated here, total sway velocity and relative landing impulse are the most reliable measures of single-leg balance and landing performance, respectively. These measures should be considered for monitoring potential changes in postural control in professional rugby union.

  13. Stability of an ERP-based measure of brain network activation (BNA) in athletes: A new electrophysiological assessment tool for concussion.

    PubMed

    Eckner, James T; Rettmann, Ashley; Narisetty, Naveen; Greer, Jacob; Moore, Brandon; Brimacombe, Susan; He, Xuming; Broglio, Steven P

    2016-01-01

    To determine test-re-test reliabilities of novel Evoked Response Potential (ERP)-based Brain Network Activation (BNA) scores in healthy athletes. Observational, repeated-measures study. Forty-two healthy male and female high school and collegiate athletes completed auditory oddball and go/no-go ERP assessments at baseline, 1 week, 6 weeks and 1 year. The BNA algorithm was applied to the ERP data, considering electrode location, frequency band, peak latency and normalized amplitude to generate seven unique BNA scores for each testing session. Mean BNA scores, intra-class correlation coefficient (ICC) values and reliable change (RC) values were calculated for each of the seven BNA networks. BNA scores ranged from 46.3 ± 34.9 to 69.9 ± 22.8, ICC values ranged from 0.46-0.65 and 95% RC values ranged from 38.3-68.1 across the seven networks. The wide range of BNA scores observed in this population of healthy athletes suggests that a single BNA score or set of BNA scores from a single after-injury test session may be difficult to interpret in isolation without knowledge of the athlete's own baseline BNA score(s) and/or the results of serial tests performed at additional time points. The stability of each BNA network should be considered when interpreting test-re-test BNA score changes.

  14. Inter- and intra-observer reliability of clinical movement-control tests for marines

    PubMed Central

    2012-01-01

    Background Musculoskeletal disorders particularly in the back and lower extremities are common among marines. Here, movement-control tests are considered clinically useful for screening and follow-up evaluation. However, few studies have addressed the reliability of clinical tests, and no such published data exists for marines. The present aim was therefore to determine the inter- and intra-observer reliability of clinically convenient tests emphasizing movement control of the back and hip among marines. A secondary aim was to investigate the sensitivity and specificity of these clinical tests for discriminating musculoskeletal pain disorders in this group of military personnel. Methods This inter- and intra-observer reliability study used a test-retest approach with six standardized clinical tests focusing on movement control for back and hip. Thirty-three marines (age 28.7 yrs, SD 5.9) on active duty volunteered and were recruited. They followed an in-vivo observation test procedure that covered both low- and high-load (threshold) tasks relevant for marines on operational duty. Two independent observers simultaneously rated performance as “correct” or “incorrect” following a standardized assessment protocol. Re-testing followed 7–10 days thereafter. Reliability was analysed using kappa (κ) coefficients, while discriminative power of the best-fitting tests for back- and lower-extremity pain was assessed using a multiple-variable regression model. Results Inter-observer reliability for the six tests was moderate to almost perfect with κ-coefficients ranging between 0.56-0.95. Three tests reached almost perfect inter-observer reliability with mean κ-coefficients > 0.81. However, intra-observer reliability was fair-to-moderate with mean κ-coefficients between 0.22-0.58. Three tests achieved moderate intra-observer reliability with κ-coefficients > 0.41. Combinations of one low- and one high-threshold test best discriminated prior back pain, but results were inconsistent for lower-extremity pain. Conclusions Our results suggest that clinical tests of movement control of back and hip are reliable for use in screening protocols using several observers with marines. However, test-retest reproducibility was less accurate, which should be considered in follow-up evaluations. The results also indicate that combinations of low- and high-threshold tests have discriminative validity for prior back pain, but were inconclusive for lower-extremity pain. PMID:23273285

  15. Screening of the spine in adolescents: inter- and intra-rater reliability and measurement error of commonly used clinical tests.

    PubMed

    Aartun, Ellen; Degerfalk, Anna; Kentsdotter, Linn; Hestbaek, Lise

    2014-02-10

    Evidence on the reliability of clinical tests used for the spinal screening of children and adolescents is currently lacking. The aim of this study was to determine the inter- and intra-rater reliability and measurement error of clinical tests commonly used when screening young spines. Two experienced chiropractors independently assessed 111 adolescents aged 12-14 years who were recruited from a primary school in Denmark. A standardised examination protocol was used to test inter-rater reliability including tests for scoliosis, hypermobility, general mobility, inter-segmental mobility and end range pain in the spine. Seventy-five of the 111 subjects were re-examined after one to four hours to test intra-rater reliability. Percentage agreement and Cohen's Kappa were calculated for binary variables, and interclass correlation (ICC) and Bland-Altman plots with Limits of Agreement (LoA) were calculated for continuous measures. Inter-rater percentage agreement for binary data ranged from 59.5% to 100%. Kappa ranged from 0.06-1.00. Kappa ≥ 0.40 was seen for elbow, thumb, fifth finger and trunk/hip flexion hypermobility, pain response in inter-segmental mobility and end range pain in lumbar flexion and extension. For continuous data, ICCs ranged from 0.40-0.95. Only forward flexion as measured by finger-to-floor distance reached an acceptable ICC(≥ 0.75). Overall, results for intra-rater reliability were better than for inter-rater reliability but for both components, the LoA were quite wide compared with the range of assessments. Some clinical tests showed good, and some tests poor, reliability when applied in a spinal screening of adolescents. The results could probably be improved by additional training and further test standardization. This is the first step in evaluating the value of these tests for the spinal screening of adolescents. Future research should determine the association between these tests and current and/or future neck and back pain.

  16. Are laboratory tests always needed? Frequency and causes of laboratory overuse in a hospital setting.

    PubMed

    Cadamuro, Janne; Gaksch, Martin; Wiedemann, Helmut; Lippi, Giuseppe; von Meyer, Alexander; Pertersmann, Astrid; Auer, Simon; Mrazek, Cornelia; Kipman, Ulrike; Felder, Thomas K; Oberkofler, Hannes; Haschke-Becher, Elisabeth

    2018-04-01

    Inappropriate utilization of laboratory resources is an increasing concern especially in high-throughput facilities. Until now, no reliable information has been published addressing to which extent laboratory results are actually used for clinical decision-making. Therefore, we aimed to close this gap using a novel retrospective approach including a survey of clinicians and nurses. We retrospectively evaluated the number of re-orders for potassium (K), lactate dehydrogenase (LD), aspartate-aminotransferase (AST), activated partial thromboplastin-time (APTT) and prothrombin-time/INR (PT/INR), after the initial order had to be cancelled due to preanalytical non-conformities. We analyzed subgroups regarding time to re-order, ward and sample priority (urgent vs. routine). Subsequently, we surveyed clinicians and nurses, asking for their estimate of the amount of failed re-orders as well as for possible reasons. From initially cancelled tests, only ~20% of K, LD, AST and ~30% of APTT and PT/INR tests were re-ordered within 24 h. 70% of the investigated clinical chemistry and 60% of coagulation tests were re-ordered one week after cancellation or not at all. Survey participants quite accurately estimated these numbers. Routine laboratory panels, short stay of out-patients, obsolete test results and avoiding additional phlebotomies were the main reasons for not re-ordering cancelled tests. Overall, 60-70% of test results in the investigated assays ordered in a high throughput laboratory are potentially inappropriate or of doubtful clinically importance. Although clinicians and nurses are aware of this situation, it is the duty of laboratory specialists to overcome overutilization in close collaboration with all involved healthcare workers. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  17. RELIABILITY OF THE TUCK JUMP INJURY RISK SCREENING ASSESSMENT IN ELITE MALE YOUTH SOCCER PLAYERS

    PubMed Central

    READ, PAUL; OLIVER, JON L.; DE STE CROIX, MARK B.A.; MYER, GREGORY D.; LLOYD, RHODRI S.

    2015-01-01

    Altered neuromuscular control has been suggested as a mechanism for injury in soccer players. Ligamentous injuries most often occur during dynamic movements, such as decelerations from jump-landing maneuvers where high risk movement patterns are present. The assessment of kinematic variables during jump-landing tasks as part of a pre-participation screen is useful in the identification of injury risk. An example of a field-based screening tool is the repeated tuck jump assessment. The purpose of this study was to analyze the within-subject variation of the tuck jump screening assessment in elite male youth soccer players. 25 pre and 25 post-peak height velocity (PHV) elite male youth soccer players from the academy of a professional English soccer club completed the assessment. A test, re-test design was used to explore the within-subject inter-session reliability. Technique was graded retrospectively against the 10-point criteria set out in the screening protocol using two-dimensional video cameras. The typical error range reported for tuck jump total score (0.90 – 1.01 in pre and post-PHV players respectively) was considered acceptable. When each criteria was analyzed individually, Kappa coefficient determined that knee valgus was the only criterion to reach substantial agreement across the two test sessions for both groups. The results of this study suggest that although tuck jump total score may be reliably assessed in elite male youth soccer players, caution should be applied in solely interpreting the composite score due to the high within-subject variation in a number of the individual criteria. Knee valgus may be reliably used to screen elite youth male soccer players for this plyometric technique error and for test, re-test comparison. PMID:26562715

  18. Examination of the Test-Retest Reliability of a Computerized Neurocognitive Test Battery.

    PubMed

    Nakayama, Yusuke; Covassin, Tracey; Schatz, Philip; Nogle, Sally; Kovan, Jeff

    2014-08-01

    Test-retest reliability is a critical issue in the utility of computer-based neurocognitive assessment paradigms employing baseline and postconcussion tests. Researchers have reported low test-retest reliability for the Immediate Post Concussion Assessment and Cognitive Testing (ImPACT) across an interval of 45 and 50 days. To re-examine the test-retest reliability of the ImPACT between baseline, 45 days, and 50 days. Descriptive laboratory study. Eighty-five physically active college students (51 male, 34 female) volunteered for this study. Participants completed the ImPACT as well as a 15-item memory test at baseline, 45 days, and 50 days. Intraclass correlation coefficients (ICCs) were calculated for ImPACT composite scores, and change scores were calculated using reliable change indices (RCIs) and regression-based methods (RBMs) at 80% and 95% confidence intervals (CIs). The respective ICCs for baseline to day 45, day 45 to day 50, baseline to day 50, and overall were as follows: verbal memory (0.76, 0.69, 0.65, and 0.78), visual memory (0.72, 0.66, 0.60, and 0.74), visual motor (processing) speed (0.87, 0.88, 0.85, and 0.91), and reaction time (0.67, 0.81, 0.71, and 0.80). All ICCs exceeded the threshold value of 0.60 for acceptable test-retest reliability. All cases fell well within the 80% CI for both the RCI and RBM, while 1% to 5% of cases fell outside the 95% CI for the RCI and 1% for the RBM. Results suggest that the ImPACT is a reliable neurocognitive test battery at 45 and 50 days after the baseline assessment. The current findings agree with those of other reliability studies that have reported acceptable ICCs across 30-day to 1-year testing intervals, and they support the utility of the ImPACT for the multidisciplinary approach to concussion management. This study suggests that the computerized neurocognitive test battery, ImPACT, is a reliable test for postconcussion serial assessments. However, when managing concussed athletes, the ImPACT should not be used as a stand-alone measure. © 2014 The Author(s).

  19. The Persian Version of the "Life Satisfaction Scale": Construct Validity and Test-Re-Test Reliability among Iranian Older Adults.

    PubMed

    Moghadam, Manije; Salavati, Mahyar; Sahaf, Robab; Rassouli, Maryam; Moghadam, Mojgan; Kamrani, Ahmad Ali Akbari

    2018-03-01

    After forward-backward translation, the LSS was administered to 334 Persian speaking, cognitively healthy elderly aged 60 years and over recruited through convenience sampling. To analyze the validity of the model's constructs and the relationships between the constructs, a confirmatory factor analysis followed by PLS analysis was performed. The Construct validity was further investigated by calculating the correlations between the LSS and the "Short Form Health Survey" (SF-36) subscales measuring similar and dissimilar constructs. The LSS was re-administered to 50 participants a month later to assess the reliability. For the eight-factor model of the life satisfaction construct, adequate goodness of fit between the hypothesized model and the model derived from the sample data was attained (positive and statistically significant beta coefficients, good R-squares and acceptable GoF). Construct validity was supported by convergent and discriminant validity, and correlations between the LSS and SF-36 subscales. Minimum Intraclass Correlation Coefficient level of 0.60 was exceeded by all subscales. Minimum level of reliability indices (Cronbach's α, composite reliability and indicator reliability) was exceeded by all subscales. The Persian-version of the Life Satisfaction Scale is a reliable and valid instrument, with psychometric properties which are consistent with the original version.

  20. Post-Test Analysis of a 10-Year Sodium Heat Pipe Life Test

    NASA Technical Reports Server (NTRS)

    Rosenfeld, John H.; Locci, Ivan E.; Sanzi, James L.; Hull, David R.; Geng, Steven M.

    2011-01-01

    High-temperature heat pipes are being evaluated for use in energy conversion applications such as fuel cells, gas turbine re-combustors, Stirling cycle heat sources; and with the resurgence of space nuclear power both as reactor heat removal elements and as radiator elements. Long operating life and reliable performance are critical requirements for these applications. Accordingly, long-term materials compatibility is being evaluated through the use of high-temperature life test heat pipes. Thermacore, Inc., has carried out a sodium heat pipe 10-year life test to establish long-term operating reliability. Sodium heat pipes have demonstrated favorable materials compatibility and heat transport characteristics at high operating temperatures in air over long time periods. A representative one-tenth segment Stirling Space Power Converter heat pipe with an Inconel 718 envelope and a stainless steel screen wick has operated for over 87,000 hr (10 years) at nearly 700 C. These life test results have demonstrated the potential for high-temperature heat pipes to serve as reliable energy conversion system components for power applications that require long operating lifetime with high reliability. Detailed design specifications, operating history, and post-test analysis of the heat pipe and sodium working fluid are described. Lessons learned and future life test plans are also discussed.

  1. Reliability of Single-Leg Balance and Landing Tests in Rugby Union; Prospect of Using Postural Control to Monitor Fatigue

    PubMed Central

    Troester, Jordan C.; Jasmin, Jason G.; Duffield, Rob

    2018-01-01

    The present study examined the inter-trial (within test) and inter-test (between test) reliability of single-leg balance and single-leg landing measures performed on a force plate in professional rugby union players using commercially available software (SpartaMARS, Menlo Park, USA). Twenty-four players undertook test – re-test measures on two occasions (7 days apart) on the first training day of two respective pre-season weeks following 48h rest and similar weekly training loads. Two 20s single-leg balance trials were performed on a force plate with eyes closed. Three single-leg landing trials were performed by jumping off two feet and landing on one foot in the middle of a force plate 1m from the starting position. Single-leg balance results demonstrated acceptable inter-trial reliability (ICC = 0.60-0.81, CV = 11-13%) for sway velocity, anterior-posterior sway velocity, and mediolateral sway velocity variables. Acceptable inter-test reliability (ICC = 0.61-0.89, CV = 7-13%) was evident for all variables except mediolateral sway velocity on the dominant leg (ICC = 0.41, CV = 15%). Single-leg landing results only demonstrated acceptable inter-trial reliability for force based measures of relative peak landing force and impulse (ICC = 0.54-0.72, CV = 9-15%). Inter-test results indicate improved reliability through the averaging of three trials with force based measures again demonstrating acceptable reliability (ICC = 0.58-0.71, CV = 7-14%). Of the variables investigated here, total sway velocity and relative landing impulse are the most reliable measures of single-leg balance and landing performance, respectively. These measures should be considered for monitoring potential changes in postural control in professional rugby union. Key points Single-leg balance demonstrated acceptable inter-trial and inter-test reliability. Single-leg landing demonstrated good inter-trial and inter-test reliability for measures of relative peak landing force and relative impulse, but not time to stabilization. Of the variables investigated, sway velocity and relative landing impulse are the most reliable measures of single-leg balance and landing respectively, and should considered for monitoring changes in postural control. PMID:29769817

  2. Systems Issues In Terrestrial Fiber Optic Link Reliability

    NASA Astrophysics Data System (ADS)

    Spencer, James L.; Lewin, Barry R.; Lee, T. Frank S.

    1990-01-01

    This paper reviews fiber optic system reliability issues from three different viewpoints - availability, operating environment, and evolving technologies. Present availability objectives for interoffice links and for the distribution loop must be re-examined for applications such as the Synchronous Optical Network (SONET), Fiber-to-the-Home (FTTH), and analog services. The hostile operating environments of emerging applications (such as FTTH) must be carefully considered in system design as well as reliability assessments. Finally, evolving technologies might require the development of new reliability testing strategies.

  3. Ten Year Operating Test Results and Post-Test Analysis of a 1/10 Segment Stirling Sodium Heat Pipe, Phase III

    NASA Technical Reports Server (NTRS)

    Rosenfeld, John, H; Minnerly, Kenneth, G; Dyson, Christopher, M.

    2012-01-01

    High-temperature heat pipes are being evaluated for use in energy conversion applications such as fuel cells, gas turbine re-combustors, Stirling cycle heat sources; and with the resurgence of space nuclear power both as reactor heat removal elements and as radiator elements. Long operating life and reliable performance are critical requirements for these applications. Accordingly, long-term materials compatibility is being evaluated through the use of high-temperature life test heat pipes. Thermacore, Inc., has carried out a sodium heat pipe 10-year life test to establish long-term operating reliability. Sodium heat pipes have demonstrated favorable materials compatibility and heat transport characteristics at high operating temperatures in air over long time periods. A representative one-tenth segment Stirling Space Power Converter heat pipe with an Inconel 718 envelope and a stainless steel screen wick has operated for over 87,000 hr (10 yr) at nearly 700 C. These life test results have demonstrated the potential for high-temperature heat pipes to serve as reliable energy conversion system components for power applications that require long operating lifetime with high reliability. Detailed design specifications, operating history, and post-test analysis of the heat pipe and sodium working fluid are described.

  4. Validation of the Italian version of the Coma Recovery Scale-Revised (CRS-R).

    PubMed

    Sacco, Simona; Altobelli, Emma; Pistarini, Caterina; Cerone, Davide; Cazzulani, Benedetta; Carolei, Antonio

    2011-01-01

    To validate the Italian version of the Coma Recovery Scale-Revised (CRS-R). Two observers applied the Italian version of the CRS-R to selected patients. On day 1, observer A and B independently scored each patient; the comparison of their observations was used to evaluate inter-observer agreement. On day 2, observer A completed a second evaluation and the comparison of this observation with that obtained on day 1 by the same observer was used to evaluate test-re-test agreement. For each evaluation, also diagnostic impression (vegetative state/minimally conscious state) was reported. Thirty-eight patients were evaluated (mean age ± SD, 58.9 ± 13.8 years). Inter-observer (ρ = 0.81; p < 0.001) as well as test-re-test agreement (ρ = 0.97; p < 0.001) for the total score was high. Inter-observer agreement was excellent for the communication sub-scale, good for the auditory, visual and motor sub-scales and moderate for the oromotor/verbal and arousal sub-scales. Test-re-test agreement was excellent for the visual, motor, oromotor/verbal and communication sub-scales, good for the auditory sub-scale and moderate for the arousal sub-scale. When considering the diagnostic impression, inter-observer agreement was good (κ = 0.75; p < 0.001) and test-re-test agreement was excellent (κ = 0.92; p < 0.001). The Italian version of the CRS-R can be administered reliably and can be also employed to discriminate patients in vegetative and in minimally conscious state.

  5. Progressive brain atrophy in patients with chronic neuropsychiatric symptoms after mild traumatic brain injury: a preliminary study.

    PubMed

    Ross, David E; Ochs, Alfred L; Seabaugh, Jan M; Demark, Michael F; Shrader, Carole R; Marwitz, Jennifer H; Havranek, Michael D

    2012-01-01

    NeuroQuant® is a recently developed, FDA-approved software program for measuring brain MRI volume in clinical settings. The aims of this study were as follows: (1) to examine the test-retest reliability of NeuroQuant®; (2) to test the hypothesis that patients with mild traumatic brain injury (TBI) would have abnormally rapid progressive brain atrophy; and (3) to test the hypothesis that progressive brain atrophy in patients with mild TBI would be associated with vocational outcome. Sixteen patients with mild TBI were compared to 20 normal controls. Vocational outcome was assessed with the Glasgow Outcome Scale-Extended (GOSE) and Disability Rating Scale (DRS). NeuroQuant® showed high test-re-test reliability. Patients had abnormally rapid progressive atrophy in several brain regions and the rate of atrophy was associated with inability to return to work. NeuroQuant®, is a reliable and valid method for assessing the anatomic effects of TBI. Progression of atrophy may continue for years after injury, even in patients with mild TBI.

  6. Strategies for Improving U.S. Air Force Productivity: Developing Methodologies for Assessing the Potential Relationship between Communication Behaviors and Productivity.

    DTIC Science & Technology

    1980-09-01

    1176 NL EmillllllllEhmhmmhhhhhmhu ,mhhmmhhhhmhhhu Ehmmhhmhhmhhl EllhlhElhlhEEE Emmhhhhhhmmhu 1 II 12.5 111111.25 1 I1 6 MICROCOPY RESOLUTION TEST ...Technician Performance t/-O7 20J ABSTRCT fContinue an reverse aid* it necesary and Identify by block number) ILJ Liedhe poetwas a preliminary testing of a...of work characteristics. These were evaluated according to re- sponse patterns, factor structure, and/or reliability indicants.. Preliminary testing

  7. Developing and testing new smoking measures for the Health Plan Employer Data and Information Set.

    PubMed

    Pbert, Lori; Vuckovic, Nancy; Ockene, Judith K; Hollis, Jack F; Riedlinger, Karen

    2003-04-01

    To develop and test items for the Health Plan Employee Data and Information Set (HEDIS) that assess delivery of the full range of provider-delivered tobacco interventions. The authors identified potential items via literature review; items were reviewed by national experts. Face validity of candidate items was tested in focus groups. The final survey was sent to a random sample of 1711 adult primary care patients; the re-test survey was sent to self-identified smokers. The process identified reliable items to capture provider assessment of motivation and provision of assistance and follow-up. One can reliably assess patient self-report of provider delivery of the full range of brief tobacco interventions. Such assessment and feedback to health plans and providers may increase use of evidence-based brief interventions.

  8. Individualized quality of life in patients with low back pain: reliability and validity of the Patient Generated Index.

    PubMed

    Løchting, Ida; Grotle, Margreth; Storheim, Kjersti; Werner, Erik L; Garratt, Andrew M

    2014-09-01

    To evaluate the reliability and validity of the improved version of the Patient Generated Index (PGI) in patients with low back pain. The PGI was administered to 90 patients attending care in 1 of 6 institutions in Norway and evaluated for reliability and validity. The questionnaire was given out to 61 patients for re-test purposes. The PGI was completed correctly by 80 (88.9%) patients and, of the 61 patients responding to the re-test, 50 (82.0%) completed both surveys correctly. PGI scores were approximately normally distributed, with a median of 40 (range 80), where 100 is the best possible quality of life. There were no floor or ceiling effects. The 5 most frequently listed areas affecting quality of life were pain, sleep, stiffness, socializing and housework. The test-retest intraclass correlation coefficient was 0.73. The smallest detectable changes for individual and group purposes were 32.8 and 4.6, respectively. The correlations between PGI scores and other instrument scores followed a priori hypotheses of low to moderate correlations. The PGI has evidence for reliability and validity in Norwegian patients with low back pain at the group level and may be considered for application in intervention studies when a comprehensive evaluation of quality of life is important. However, the smallest detectable change, of approximately 30 points, may be considered too large for individual purposes in clinical applications.

  9. Evaluating the reliability of an injury prevention screening tool: Test-retest study.

    PubMed

    Gittelman, Michael A; Kincaid, Madeline; Denny, Sarah; Wervey Arnold, Melissa; FitzGerald, Michael; Carle, Adam C; Mara, Constance A

    2016-10-01

    A standardized injury prevention (IP) screening tool can identify family risks and allow pediatricians to address behaviors. To assess behavior changes on later screens, the tool must be reliable for an individual and ideally between household members. Little research has examined the reliability of safety screening tool questions. This study utilized test-retest reliability of parent responses on an existing IP questionnaire and also compared responses between household parents. Investigators recruited parents of children 0 to 1 year of age during admission to a tertiary care children's hospital. When both parents were present, one was chosen as the "primary" respondent. Primary respondents completed the 30-question IP screening tool after consent, and they were re-screened approximately 4 hours later to test individual reliability. The "second" parent, when present, only completed the tool once. All participants received a 10-dollar gift card. Cohen's Kappa was used to estimate test-retest reliability and inter-rater agreement. Standard test-retest criteria consider Kappa values: 0.0 to 0.40 poor to fair, 0.41 to 0.60 moderate, 0.61 to 0.80 substantial, and 0.81 to 1.00 as almost perfect reliability. One hundred five families participated, with five lost to follow-up. Thirty-two (30.5%) parent dyads completed the tool. Primary respondents were generally mothers (88%) and Caucasian (72%). Test-retest of the primary respondents showed their responses to be almost perfect; average 0.82 (SD = 0.13, range 0.49-1.00). Seventeen questions had almost perfect test-retest reliability and 11 had substantial reliability. However, inter-rater agreement between household members for 12 objective questions showed little agreement between responses; inter-rater agreement averaged 0.35 (SD = 0.34, range -0.19-1.00). One question had almost perfect inter-rater agreement and two had substantial inter-rater agreement. The IP screening tool used by a single individual had excellent test-retest reliability for nearly all questions. However, when a reporter changes from pre- to postintervention, differences may reflect poor reliability or different subjective experiences rather than true change.

  10. Psychometric properties of the Finnish version of the Young Person's Clinical Outcomes in Routine Evaluation (YP-CORE) questionnaire.

    PubMed

    Gergov, Vera; Lahti, Jari; Marttunen, Mauri; Lipsanen, Jari; Evans, Chris; Ranta, Klaus; Laitila, Aarno; Lindberg, Nina

    2017-05-01

    An increasing need exists for suitable measures to evaluate treatment outcome in adolescents. YP-CORE is a pan-theoretical brief questionnaire developed for this purpose, but it lacks studies in different cultures or languages. To explore the acceptability, factor structure, reliability, validity, and sensitivity to change of the Finnish translation of YP-CORE. The study was conducted at the Department of Adolescent Psychiatry, Helsinki University Central Hospital. A Finnish translation was prepared by a team of professionals and adolescents. A clinical sample of 104 patients was asked to complete the form together with BDI-21 and BAI, and 92 of them filled the forms again after a 3-month treatment. Analysis included acceptability, confirmatory factor analysis, internal and test-re-test reliability, concurrent validity, influence of gender and age, and criteria for reliable change. YP-CORE was well accepted, and the rate of missing values was low. Internal consistency (α = 0.83-.92) and test-re-test reliability were good (r = 0.69), and the results of CFA supported a one-factor model. YP-CORE showed good concurrent validity against two widely used symptom-specific measures (r = 0.62-0.87). Gender had a moderately strong effect on the scores (d = 0.67), but the effect of age was not as evident. The measure was sensitive to change, showing a larger effect size (d = 0.55) than in the BDI-21 and BAI (d = 0.31-0.50). The results show that the translation of YP-CORE into Finnish has been successful, the YP-CORE has good psychometric properties, and the measure could be taken into wider use in clinical settings for outcome measurement in adolescents.

  11. Reproducibility of self-reported pap test utilization in middle-aged African-American women.

    PubMed

    Hoyo, Cathrine; Ostbye, Truls; Skinner, Celette S; Yarnall, Kimberly S H; Chowdhary, Jaspreet

    2005-01-01

    Both clinicians who perform Pap tests and prescribe re-screens and public health officials, who periodically evaluate the success of Pap test screening programs, often depend on women to self-report their most recent Pap test. However, reliability of self-reported Pap test utilization is putatively low, and even lower in African-American women compared to Whites. Between 2001 and 2002, Pap test screening histories were obtained from 144 African-American women, aged 45 to 64 years at two in-person interviews conducted three to six weeks apart. Reproducibility of self-reported Pap test was substantial (kappa=0.64; 95% confidence interval: .46-.82), with the highest agreement among women with greater income and educational attainment, and those who were younger. This level of reproducibility is likely sufficient both to evaluate the population coverage of public health screening programs and for prescribing re-screens among younger African-American women and those of higher income and education. Not using self-reports to base clinic decisions may still be prudent among those with less education.

  12. Repeated Sprint Ability in Young Basketball Players: Multi-direction vs. One-Change of Direction (Part 1)

    PubMed Central

    Padulo, Johnny; Bragazzi, Nicola L.; Nikolaidis, Pantelis T.; Dello Iacono, Antonio; Attene, Giuseppe; Pizzolato, Fabio; Dal Pupo, Juliano; Zagatto, Alessandro M.; Oggianu, Marcello; Migliaccio, Gian M.

    2016-01-01

    The aim of the present study was to examine the reliability of a novel multi-direction repeated sprint ability (RSA) test [RSM; 10 × (6 × 5-m)] compared with a RSA with one change of direction [10 × (2 × 15-m)], and the relationship of the RSM and RSA with Yo-Yo intermittent recovery test level 1 (Yo-Yo IR1) and jump performances [squat jump (SJ) and counter-movement-jump (CMJ)]. Thirty-six (male, n = 14, female n = 22) young basketball players (age 16.0 ± 0.9 yrs) performed the RSM, RSA, Yo-Yo IR1, SJ, and CMJ, and were re-tested only for RSM and RSA after 1 week. The absolute error of reliability (standard error of the measurement) was lower than 0.212 and 0.617-s for the time variables of the RSA and RSM test, respectively. Performance in the RSA and RSM test significantly correlated with CMJ and SJ. The best time, worst time, and total time of the RSA and RSM test were negatively correlated with Yo-Yo IR1 distance. Based on these findings, consistent with previously published studies, it was concluded that the novel RSM test was valid and reliable. PMID:27148072

  13. Validation of the breast evaluation questionnaire for breast hypertrophy and breast reduction.

    PubMed

    Lewin, Richard; Elander, Anna; Lundberg, Jonas; Hansson, Emma; Thorarinsson, Andri; Claudelin, Malin; Bladh, Helena; Lidén, Mattias

    2018-06-13

    There is a lack of published, validated questionnaires for evaluating psychosocial morbidity in patients with breast hypertrophy undergoing breast reduction surgery. To validate the breast evaluation questionnaire (BEQ), originally developed for the assessment of breast augmentation patients, for the assessment of psychosocial morbidity in patients with breast hypertrophy undergoing breast reduction surgery. Validation study Subjects: Women with macromastia Methods: The validation of the BEQ, adapted to breast reduction, was performed in several steps. Content validity, reliability, construct validity and responsiveness were assessed. The original version was adjusted according to the results for content validity and resulted in item reduction and a modified BEQ (mBEQ) that was then assessed for reliability, construct validity and responsiveness. Internal and external validation was performed for the modified BEQ. Convergent validity was tested against Breast-Q (reduction) and discriminate validity was tested against the SF-36. Known-groups validation revealed significant differences between the normal population and patients undergoing breast reduction surgery. The BEQ showed good reliability by test-re-test analysis and high responsiveness. The modified BEQ may be reliable, valid and responsive instrument for assessing women who undergo breast reduction.

  14. Reliability based design including future tests and multiagent approaches

    NASA Astrophysics Data System (ADS)

    Villanueva, Diane

    The initial stages of reliability-based design optimization involve the formulation of objective functions and constraints, and building a model to estimate the reliability of the design with quantified uncertainties. However, even experienced hands often overlook important objective functions and constraints that affect the design. In addition, uncertainty reduction measures, such as tests and redesign, are often not considered in reliability calculations during the initial stages. This research considers two areas that concern the design of engineering systems: 1) the trade-off of the effect of a test and post-test redesign on reliability and cost and 2) the search for multiple candidate designs as insurance against unforeseen faults in some designs. In this research, a methodology was developed to estimate the effect of a single future test and post-test redesign on reliability and cost. The methodology uses assumed distributions of computational and experimental errors with re-design rules to simulate alternative future test and redesign outcomes to form a probabilistic estimate of the reliability and cost for a given design. Further, it was explored how modeling a future test and redesign provides a company an opportunity to balance development costs versus performance by simultaneously designing the design and the post-test redesign rules during the initial design stage. The second area of this research considers the use of dynamic local surrogates, or surrogate-based agents, to locate multiple candidate designs. Surrogate-based global optimization algorithms often require search in multiple candidate regions of design space, expending most of the computation needed to define multiple alternate designs. Thus, focusing on solely locating the best design may be wasteful. We extended adaptive sampling surrogate techniques to locate multiple optima by building local surrogates in sub-regions of the design space to identify optima. The efficiency of this method was studied, and the method was compared to other surrogate-based optimization methods that aim to locate the global optimum using two two-dimensional test functions, a six-dimensional test function, and a five-dimensional engineering example.

  15. Translation, cultural adaption, and test-retest reliability of Chinese versions of the Edinburgh Handedness Inventory and Waterloo Footedness Questionnaire.

    PubMed

    Yang, Nan; Waddington, Gordon; Adams, Roger; Han, Jia

    2018-05-01

    Quantitative assessments of handedness and footedness are often required in studies of human cognition and behaviour, yet no reliable Chinese versions of commonly used handedness and footedness questionnaires are available. Accordingly, the objective of the present study was to translate the Edinburgh Handedness Inventory (EHI) and the Waterloo Footedness Questionnaire-Revised (WFQ-R) into Mandarin Chinese and to evaluate the reliability and validity of these translated versions in healthy Chinese people. In the first stage of the study, Chinese versions of the EHI and WFQ-R were produced from a process of translation, back translation and examination, with necessary cultural adaptations. The second stage involved determining the reliability and validity of the translated EHI and WFQ-R for the Chinese population. One hundred and ten Chinese participants were tested online, and the results showed that the Cronbach's alpha coefficient of internal consistency was 0.877 for the translated EHI and 0.855 for the translated WFQ-R. Another 170 Chinese participants were tested and re-tested after a 30-day interval. The intra-class correlation coefficients showed high reliability, 0.898 for the translated EHI and 0.869 for the translated WFQ-R. This preliminary validation study found the translated versions to be reliable and valid tools for assessing handedness and footedness in this population.

  16. Aerodynamic Performance of Hand Launch Glider

    NASA Astrophysics Data System (ADS)

    Koike, Masaru; Ishii, Mitsuru

    In recent years Micro Air Vehicles (MAV) for disaster aerial video are developed vigorously. In order to improve aerodynamic performance of MAV wing performance in low Reynolds numbers (Re) need to be improved, but research on the theme are very rare. In category of Hand Launch Glider, a kind of model aircraft, glide performance are competed, as a result high performance airfoils in Re is around 20,000 are developed. Therefore for MAV's aerodynamic performance improvement airfoils of Hand Launch Gliders should be referred and aerodynamic characteristics of the airfoils desired to be studied. So in this research, aerodynamic characteristics of the gliders are measured in wind tunnel. And also consistency between wind tunnel test and glide test in calm air is examined to confirm reliability of wind tunnel test. Comparison of different airfoils and flow visualization are also performed.

  17. A Primer for DoD Reliability, Maintainability, Safety, and Logistics Standards, 1992

    DTIC Science & Technology

    1991-10-01

    equipment, identified in the order of application (i.e., assembly, unit and system screens). Screening Strength ( SS ) - The probability that a screen...As’- ss equipment suitability for its intended operational environment. c. Verify contractual compliance. Each test method is divided into two...SIMULA-ITno Q.A. j FABRICATION, VALIDATION AD CONCERNS j PACKAGE AND SAnSFACTORY MBI Y QUALIMCATION RE UIREMENTS NO QRA TESTS YES QMLFOR TECHNOLOGY

  18. Establishing the reliability and concurrent validity of physical performance tests using virtual reality equipment for community-dwelling healthy elders.

    PubMed

    Griswold, David; Rockwell, Kyle; Killa, Carri; Maurer, Michael; Landgraff, Nancy; Learman, Ken

    2015-01-01

    The aim of this study was to determine the reliability and concurrent validity of commonly used physical performance tests using the OmniVR Virtual Rehabilitation System for healthy community-dwelling elders. Participants (N = 40) were recruited by the authors and were screened for eligibility. The initial method of measurement was randomized to either virtual reality (VR) or clinically based measures (CM). Physical performance tests included the five times sit to stand, Timed Up and Go (TUG), Forward Functional Reach (FFR) and 30-s stand test. A random number generator determined the testing order. The test-re-test reliability for the VR and CM was determined. Furthermore, concurrent validity was determined using a Pearson product moment correlation (Pearson r). The VR demonstrated excellent reliability for 5 × STS intraclass correlation coefficient (ICC) = 0.931(3,1), FFR ICC = 0.846(3,1) and the TUG ICC = 0.944(3,1). The concurrent validity data for the VR and CM (ICC 3, k) were moderate for FFR ICC = 0.682, excellent 5 × STS ICC = 0.889 and excellent for the TUG ICC = 0.878. The concurrent validity of the 30-s stand test was good ICC = 0.735(3,1). This study supports the use of VR equipment for measuring physical performance tests in the clinic for healthy community-dwelling elders. Virtual reality equipment is not only used to treat balance impairments but it is also used to measure and determine physical impairments through the use of physical performance tests. Virtual reality equipment is a reliable and valid tool for collecting physical performance data for the 5 × STS, FFR, TUG and 30-s stand test for healthy community-dwelling elders.

  19. Development and reliability of a Turkish version of the Short Form-Joint Protection Behavior Assessment (JPBA-S).

    PubMed

    Tonga, Eda; Atasavun Uysal, Songul; Karayazgan, Sedef; Hayran, Mutlu; Düger, Tülin

    2016-01-01

    Clinical measurement. To adapt the original JPBA-S to a Turkish version (TUR-JPBA-S) and to investigate its reliability in assessing patients with rheumatoid arthritis (RA). Twenty-two participants with RA and 21 healthy people were videotaped while performing tasks listed in the TUR-JPBA-S. Two raters scored the video recordings for to evaluate inter-rater reliability. One rater re-analyzed the recordings at a different time point for intra-rater reliability. Participants with RA were asked to perform the same tasks after three to four weeks which was also recorded to evaluate test-retest reliability. Internal consistency (Cronbach's α value) was found to be high (0.89) for participants with RA. Our results demonstrate excellent intra-rater (ICC: 0.99, SEM 1.2) inter-rater (ICC: 0.99, SEM 1.7) reliability, apart from excellent test-retest reliability (ICC: 0.96). The TUR-JPBA-S is a valid and reliable instrument for assessing JP behavior in patients with RA in Turkey. Level 2. Copyright © 2016 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  20. Development and reliability testing of a self-report instrument to measure the office layout as a correlate of occupational sitting.

    PubMed

    Duncan, Mitch J; Rashid, Mahbub; Vandelanotte, Corneel; Cutumisu, Nicoleta; Plotnikoff, Ronald C

    2013-02-04

    Spatial configurations of office environments assessed by Space Syntax methodologies are related to employee movement patterns. These methods require analysis of floors plans which are not readily available in large population-based studies or otherwise unavailable. Therefore a self-report instrument to assess spatial configurations of office environments using four scales was developed. The scales are: local connectivity (16 items), overall connectivity (11 items), visibility of co-workers (10 items), and proximity of co-workers (5 items). A panel cohort (N = 1154) completed an online survey, only data from individuals employed in office-based occupations (n = 307) were used to assess scale measurement properties. To assess test-retest reliability a separate sample of 37 office-based workers completed the survey on two occasions 7.7 (±3.2) days apart. Redundant scale items were eliminated using factor analysis; Chronbach's α was used to evaluate internal consistency and test re-test reliability (retest-ICC). ANOVA was employed to examine differences between office types (Private, Shared, Open) as a measure of construct validity. Generalized Linear Models were used to examine relationships between spatial configuration scales and the duration of and frequency of breaks in occupational sitting. The number of items on all scales were reduced, Chronbach's α and ICCs indicated good scale internal consistency and test re-test reliability: local connectivity (5 items; α = 0.70; retest-ICC = 0.84), overall connectivity (6 items; α = 0.86; retest-ICC = 0.87), visibility of co-workers (4 items; α = 0.78; retest-ICC = 0.86), and proximity of co-workers (3 items; α = 0.85; retest-ICC = 0.70). Significant (p ≤ 0.001) differences, in theoretically expected directions, were observed for all scales between office types, except overall connectivity. Significant associations were observed between all scales and occupational sitting behaviour (p ≤ 0.05). All scales have good measurement properties indicating the instrument may be a useful alternative to Space Syntax to examine environmental correlates of occupational sitting in population surveys.

  1. Development and reliability testing of a self-report instrument to measure the office layout as a correlate of occupational sitting

    PubMed Central

    2013-01-01

    Background Spatial configurations of office environments assessed by Space Syntax methodologies are related to employee movement patterns. These methods require analysis of floors plans which are not readily available in large population-based studies or otherwise unavailable. Therefore a self-report instrument to assess spatial configurations of office environments using four scales was developed. Methods The scales are: local connectivity (16 items), overall connectivity (11 items), visibility of co-workers (10 items), and proximity of co-workers (5 items). A panel cohort (N = 1154) completed an online survey, only data from individuals employed in office-based occupations (n = 307) were used to assess scale measurement properties. To assess test-retest reliability a separate sample of 37 office-based workers completed the survey on two occasions 7.7 (±3.2) days apart. Redundant scale items were eliminated using factor analysis; Chronbach’s α was used to evaluate internal consistency and test re-test reliability (retest-ICC). ANOVA was employed to examine differences between office types (Private, Shared, Open) as a measure of construct validity. Generalized Linear Models were used to examine relationships between spatial configuration scales and the duration of and frequency of breaks in occupational sitting. Results The number of items on all scales were reduced, Chronbach’s α and ICCs indicated good scale internal consistency and test re-test reliability: local connectivity (5 items; α = 0.70; retest-ICC = 0.84), overall connectivity (6 items; α = 0.86; retest-ICC = 0.87), visibility of co-workers (4 items; α = 0.78; retest-ICC = 0.86), and proximity of co-workers (3 items; α = 0.85; retest-ICC = 0.70). Significant (p ≤ 0.001) differences, in theoretically expected directions, were observed for all scales between office types, except overall connectivity. Significant associations were observed between all scales and occupational sitting behaviour (p ≤ 0.05). Conclusion All scales have good measurement properties indicating the instrument may be a useful alternative to Space Syntax to examine environmental correlates of occupational sitting in population surveys. PMID:23379485

  2. Re-entry simulation chamber for thermo-mechanical characterisation of space materials

    NASA Astrophysics Data System (ADS)

    Liedtke, Volker

    2003-09-01

    During re-entry, materials and components are subject to very high thermal and mechanical loads. Any failure may cause loss of mission. Therefore, materials and components have to be tested under most rigid conditions to verify the suitability of the material and to verify the design of the components. The Re-Entry Simulation Chamber (RESiC) at ARC Seibersdorf research (ARCS) allows simulating the high thermal loads as well as complex mechanical load profiles that may occur during a re-entry; additionally, the influence of chemical reactions of materials with gaseous components of the atmosphere can be studied. The high vacuum chamber (better than 1×10-6 mbar) has a diameter of 650 mm and allows a sample height of 500 mm, or 1000 mm with extension flange. The gas dosing system is designed to emulate the increasing atmospheric pressure during the re-entry trajectory of a vehicle. Heating is performed by a 30 kW induction generator that allows a sufficiently rapid heating of larger components; electrically conductive materials such as metals or carbon fibre reinforced ceramics are directly heated, while for electrical insulators, susceptor plates or tubes will be employed. The uniaxial servo-hydraulic testing machine has a maximum load of 70 kN, either static or with a frequency of up to 70 Hz, with any given load profile (sinus, rectangular, triangular, ...). Strain measurements will be done by non-contacting laser speckle system for maximum flexibility and minimum instrumentation time effort (currently under application testing), or by strain gauges. All relevant process parameters are controlled and recorded by microcomputer. The highly sophisticated control software allows a convenient and reliable multi-channel data acquisition, e.g. temperatures at various positions of the test piece, pressure, loads, strains, and any other test data according to customer specifications; the data format is suitable for any further data processing. During the set-up and operation testing, the device has successfully been employed for thermal shock testing, thermal cycling and gas cycling tests, thermomechanical tests and combinations thereof, e.g. sintering or hot-pressing. During the current final test series, the device will be completed, further optimised and shall be fully operational in summer 2003.

  3. Retrogression and Re-Ageing In-Service Demonstrator Reliability Trials: Stage 3 Component Test Report

    DTIC Science & Technology

    2012-03-01

    6 4.5 Component, Furnace and Quench Bath Thermometry...................................... 6 4.6 Component Heat Treatment...7 4.6.2 Post-Retrogression Quench .................................................................... 9 4.6.3...23 5.5.2 Temperature Profile – Post-Retrogression Quenching .................... 23 5.5.3 Temperature

  4. A testing-coverage software reliability model considering fault removal efficiency and error generation.

    PubMed

    Li, Qiuying; Pham, Hoang

    2017-01-01

    In this paper, we propose a software reliability model that considers not only error generation but also fault removal efficiency combined with testing coverage information based on a nonhomogeneous Poisson process (NHPP). During the past four decades, many software reliability growth models (SRGMs) based on NHPP have been proposed to estimate the software reliability measures, most of which have the same following agreements: 1) it is a common phenomenon that during the testing phase, the fault detection rate always changes; 2) as a result of imperfect debugging, fault removal has been related to a fault re-introduction rate. But there are few SRGMs in the literature that differentiate between fault detection and fault removal, i.e. they seldom consider the imperfect fault removal efficiency. But in practical software developing process, fault removal efficiency cannot always be perfect, i.e. the failures detected might not be removed completely and the original faults might still exist and new faults might be introduced meanwhile, which is referred to as imperfect debugging phenomenon. In this study, a model aiming to incorporate fault introduction rate, fault removal efficiency and testing coverage into software reliability evaluation is developed, using testing coverage to express the fault detection rate and using fault removal efficiency to consider the fault repair. We compare the performance of the proposed model with several existing NHPP SRGMs using three sets of real failure data based on five criteria. The results exhibit that the model can give a better fitting and predictive performance.

  5. Analysis of Test-Retest Reliability, Construct Validity, and Internal Consistency of the Brazilian Version of the Pelvic Girdle Questionnaire.

    PubMed

    Simões, Luan; Teixeira-Salmela, Luci Fuscaldi; Magalhães, Lívia; Stuge, Britt; Laurentino, Glória; Wanderley, Elaine; Barros, Raphaela; Lemos, Andrea

    2018-04-24

    The purpose of this study was to evaluate test-retest reliability, construct validity, and internal consistency of the Brazilian version of the Pelvic Girdle Questionnaire (PGQ-Brazil). Analysis of the measurement properties was carried out in 4 steps. Step 1 was the pilot study, on which basis 4 hypotheses were formulated. These hypotheses were tested during the next step (construct validity, step 2) by completion of the questionnaire by the 2 groups (in pain [n = 105] and not in pain [n = 52]). For implementation of the PGQ-Brazil in the group with pain, we calculated the internal consistency (step 3) and, 7 days later, test-retest reliability (step 4) by re-application of the instrument in this group. First, the PGQ-Brazil was able to discriminate between these groups (construct validity). Second, test-retest reliability (intraclass correlation coefficients for Activities subscale [0.97 with 95% confidence interval of 0.95-0.98] and Symptoms subscale [0.98 with 95% confidence interval of 0.97-0.98] and κ coefficient between 0.50 and 0.89 for the items) was found to be good; the Bland-Altman test indicated satisfactory agreement. The Rasch analysis indicated good internal consistency, and the instrument's ability to divide the participants into at least 3 levels of skills was confirmed. In contrast, a ceiling effect was observed, as 24% of pregnant women exhibited skills superior to what the PGQ-Brazil could evaluate. The PGQ-Brazil had good internal consistency, test-retest reliability, and construct validity in assessment of limitations in activities and symptoms of pregnant women with pelvic girdle pain. Copyright © 2018. Published by Elsevier Inc.

  6. Assessing emotional status following acquired brain injury: the clinical potential of the depression, anxiety and stress scales.

    PubMed

    Ownsworth, Tamara; Little, Trudi; Turner, Ben; Hawkes, Anna; Shum, David

    2008-10-01

    To investigate the clinical potential of the Depression, Anxiety and Stress Scales (DASS 42) and its shorter version (DASS 21) for assessing emotional status following acquired brain injury. Participants included 23 individuals with traumatic brain injury (TBI), 25 individuals with brain tumour and 29 non-clinical controls. Investigations of internal consistency, test-re-test reliability, theory-consistent differences, sensitivity to change and concurrent validity were conducted. Internal consistency of the DASS was generally acceptable (r > 0.70), with the exception of the anxiety scale for the TBI sample. Test-re-test reliability (1-3 weeks) was sound for the depression scale (r > 0.75) and significant but comparatively lower for other scales (r = 0.60-0.73, p < 0.01). Theory-consistent differences were only evident between the brain tumour sample and non-clinical control sample on the anxiety scale (p < 0.01). Sensitivity to change of the DASS in the context of hospital discharge was demonstrated for depression and stress (p < 0.01), but not for anxiety (p > 0.05). Concurrent validity with the Hospital Anxiety and Depression Scale was significant for all scales of the DASS (p < 0.05). While the results generally support the clinical application of the DASS following ABI, further research examining the factor structure of existing and modified versions of the DASS is recommended.

  7. Translation of oswestry disability index into Tamil with cross cultural adaptation and evaluation of reliability and validity(§).

    PubMed

    Vincent, Joshua Israel; Macdermid, Joy Christine; Grewal, Ruby; Sekar, Vincent Prabhakaran; Balachandran, Dinesh

    2014-01-01

    Prospective longitudinal validation study. To translate and cross-culturally adapt the Oswestry Disability Index (ODI) to the Tamil language (ODI-T), and to evaluate its reliability and construct validity. ODI is widely used as a disease specific questionnaire in back pain patients to evaluate pain and disability. A thorough literature search revealed that the Tamil version of the ODI has not been previously published. The ODI was translated and cross-culturally adapted to the Tamil language according to established guidelines. 30 subjects (16 women and 14 men) with a mean age of 42.7 years (S.D. 13.6; Range 22 - 69) with low back pain were recruited to assess the psychometric properties of the ODI-T Questionnaire. Patients completed the ODI-T, Roland-Morris disability questionnaire (RMDQ), VAS-pain and VAS-disability at baseline and 24-72 hours from the baseline visit. The ODI-T displayed a high degree of internal consistency, with a Cronbach's alpha of 0.92. The test-retest reliability was high (n=30) with an ICC of 0.92 (95% CI, 0.84 to 0.96) and a mean re-test difference of 2.6 points lower on re-test. The ODI-T scores exhibited a strong correlation with the RMDQ scores (r = 0.82) p<0.01, VAS-P (r = 0.78) p<0.01 and VAS-D (r = 0.81) p<0.01. Moderate to low correlations were observed between the ODI-T and lumbar ROM (r = -0.27 to -0.53). All the hypotheses that were constructed apriori were supported. The Tamil version of the ODI Questionnaire is a valid and reliable tool that can be used to measure subjective outcomes of pain and disability in Tamil speaking patients with low back pain.

  8. Validity and reliability of the abdominal test and evaluation systems tool (ABTEST) to accurately measure abdominal force.

    PubMed

    Glenn, Jordan M; Galey, Madeline; Edwards, Abigail; Rickert, Bradley; Washington, Tyrone A

    2015-07-01

    Ability to generate force from the core musculature is a critical factor for sports and general activities with insufficiencies predisposing individuals to injury. This study evaluated isometric force production as a valid and reliable method of assessing abdominal force using the abdominal test and evaluation systems tool (ABTEST). Secondary analysis estimated 1-repetition maximum on commercially available abdominal machine compared to maximum force and average power on ABTEST system. This study utilized test-retest reliability and comparative analysis for validity. Reliability was measured using test-retest design on ABTEST. Validity was measured via comparison to estimated 1-repetition maximum on a commercially available abdominal device. Participants applied isometric, abdominal force against a transducer and muscular activation was evaluated measuring normalized electromyographic activity at the rectus-abdominus, rectus-femoris, and erector-spinae. Test, re-test force production on ABTEST was significantly correlated (r=0.84; p<0.001). Mean electromyographic activity for the rectus-abdominus (72.93% and 75.66%), rectus-femoris (6.59% and 6.51%), and erector-spinae (6.82% and 5.48%) were observed for trial-1 and trial-2, respectively. Significant correlations for the estimated 1-repetition maximum were found for average power (r=0.70, p=0.002) and maximum force (r=0.72, p<0.001). Data indicate the ABTEST can accurately measure rectus-abdominus force isolated from hip-flexor involvement. Negligible activation of erector-spinae substantiates little subjective effort among participants in the lower back. Results suggest ABTEST is a valid and reliable method of evaluating abdominal force. Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  9. A testing-coverage software reliability model considering fault removal efficiency and error generation

    PubMed Central

    Li, Qiuying; Pham, Hoang

    2017-01-01

    In this paper, we propose a software reliability model that considers not only error generation but also fault removal efficiency combined with testing coverage information based on a nonhomogeneous Poisson process (NHPP). During the past four decades, many software reliability growth models (SRGMs) based on NHPP have been proposed to estimate the software reliability measures, most of which have the same following agreements: 1) it is a common phenomenon that during the testing phase, the fault detection rate always changes; 2) as a result of imperfect debugging, fault removal has been related to a fault re-introduction rate. But there are few SRGMs in the literature that differentiate between fault detection and fault removal, i.e. they seldom consider the imperfect fault removal efficiency. But in practical software developing process, fault removal efficiency cannot always be perfect, i.e. the failures detected might not be removed completely and the original faults might still exist and new faults might be introduced meanwhile, which is referred to as imperfect debugging phenomenon. In this study, a model aiming to incorporate fault introduction rate, fault removal efficiency and testing coverage into software reliability evaluation is developed, using testing coverage to express the fault detection rate and using fault removal efficiency to consider the fault repair. We compare the performance of the proposed model with several existing NHPP SRGMs using three sets of real failure data based on five criteria. The results exhibit that the model can give a better fitting and predictive performance. PMID:28750091

  10. Prognosis of adult-onset idiopathic bile acid malabsorption.

    PubMed

    Rössel, P; Sortsøe Jensen, H; Qvist, P; Arveschoug, A

    1999-06-01

    From 1986 to 1993, 150 patients were investigated with the 75Se-homocholic acid taurine (SeHCAT) test as a late step in the investigation of chronic diarrhoea. On basis of low SeHCAT values and response to cholestyramine treatment, 33 patients were initially classified as having idiopathic bile acid malabsorption (IBAM). The aim was to describe the long-term clinical course of the disease and to assess the reliability of the SeHCAT test in diagnosing IBAM. The methods included 1) clinical follow-up with patient interview combined with information from medical records and 2) repeated SeHCAT test. The diagnosis of IBAM had to be revised in three cases (inflammatory bowel disease in two patients, Clostridium difficile infection in one). Six patients were lost to follow-up and a further four patients were excluded from re-examination either because of old age (>80 years) or bowel resection, leaving 20 patients for re-examination, of which 16 completed both clinical follow-up and a new SeHCAT test. The median duration of symptoms before initial SeHCAT test was 2.5 (1-30) years. In 13 of 16 patients symptoms persisted, and SeHCAT values remained low and almost identical to the initial value after a median observation time of 88 (51-113) months. Despite initial response to treatment with cholestyramine, six patients had to discontinue treatment because of adverse effects or other compliance problems. In three patients the SeHCAT value showed a considerable increase, and bowel function had correspondingly normalized in these cases. The study confirms the reliability of the SeHCAT test in diagnosing IBAM. Despite adult onset of symptoms, only a few patients improve after several years' observation. Treatment with cholestyramine is generally effective but not always tolerated.

  11. Misdiagnosis of Thyroid Disorders in Down Syndrome: Time to Re-Examine the Myth?

    ERIC Educational Resources Information Center

    Prasher, V.; Haque, M. S.

    2005-01-01

    There is a reported association between thyroid disorders and Down syndrome, but is this association based on valid and reliable research evidence? We evaluated thyroid function test results of 110 healthy adults with Down syndrome to determine biochemical thyroid status. Approximately two thirds were biochemically euthyroid when assessed by…

  12. One year test-retest reliability of neurocognitive baseline scores in 10- to 12-year olds.

    PubMed

    Moser, Rosemarie Scolaro; Schatz, Philip; Grosner, Emily; Kollias, Kelly

    2017-01-01

    How often youth athletes 10-12 years of age should undergo neurocognitive baseline testing remains an unanswered question. We sought to examine the test-retest reliability of annual ImPACT data in a sample of middle school athletes. Participants were 30 youth athletes, ages 10-12 years (Mean = 11.6, SD = 0.6) selected from a larger database of 10-18 year old athletes, who completed two consecutive annual baseline evaluations using the online version of ImPACT. Athlete assent and parental consent were obtained for all participants. Assessments were conducted either individually or in small groups of 2 to 3 athletes, under the supervision of a neuropsychologist or post-doctoral fellow. Test-retest coefficients were as follows: Verbal Memory .71, Visual Memory .35, Visual Motor Speed .69, Reaction Time .34. Intra-class Correlation Coefficients (single/average) were as follows: Verbal Memory .70/.83, Visual Memory .35/.52, Visual Motor Speed .69/.82, Reaction Time .34/.50. Regression-based measures to correct for practice effects revealed that only a small percentage of cases fell outside 90 and 95% confidence intervals, reflecting stability across assessments. Findings indicate that test-retest reliability of Verbal Memory and Visual Motor Speed are generally stable in 10-12 year old athletes. Nevertheless, Visual Memory Index, Reaction Time Index, and Symptom Checklist scores appear to be less reliable over time, especially compared to published data on high school athletes, suggesting the utility of re-testing on an annual basis in this younger age group.

  13. Re-evaluation of the interrelationships among the behavioral tests in rats exposed to chronic unpredictable mild stress

    PubMed Central

    Hu, Congli; Luo, Ying; Wang, Hong; Kuang, Shengnan; Liang, Guojuan; Yang, Yang; Mai, Shaoshan; Yang, Junqing

    2017-01-01

    The chronic unpredictable mild stress model of depression has been widely used as an experimental tool to investigate human psychopathology. Our objective was to provide an update on the validity and reliability of the chronic unpredictable mild stress model, by analyzing the interrelationships among the indexes using stepwise discriminant analysis and Pearson correlation coefficient to examine the possible combinations. We evaluated the depressive rats in both the presence and the absence of chronic unpredictable mild stress, using weight change, percentage of sucrose preference, coat state, splash test, open-field test, elevated plus-maze test, forced swimming test, and Morris water maze test. The results showed that 6-week-long chronic unpredictable mild stress produces significant depression and anxiety-like behavior. The combination of body weight change, percentage of sucrose preference, coat state score, open-field score, grooming latency of splash test, immobility time in force swimming test, and platform crossing in the Morris water maze test can effectively discriminate between normal and chronic unpredictable mild stress rats. Strong interrelationships were noted among these indexes in both open-field test and elevated plus-maze test. In conclusion, there might be certain criteria for the combination of behavioral endpoints, which is advantageous to more effectively and reliably assess the chronic unpredictable mild stress induced depression model. PMID:28931086

  14. A new assessment tool for patients with multiple sclerosis from Spanish-speaking countries: validation of the Brief International Cognitive Assessment for MS (BICAMS) in Argentina.

    PubMed

    Vanotti, Sandra; Smerbeck, Audrey; Benedict, Ralph H B; Caceres, Fernando

    2016-10-01

    The Brief International Cognitive Assessment for Multiple Sclerosis (BICAMS) is an international assessment tool for monitoring cognitive function in multiple sclerosis (MS) patients. BICAMS comprises the Symbol Digit Modalities Test (SDMT), the California Verbal Learning Test - Second Edition (CVLT II) and the Brief Visuospatial Memory Test - Revised (BVMT-R). Our objective was to validate and assess the reliability of BICAMS as applied in Argentina and to obtain normative data in Spanish for this population. The sample composed of 50 MS patients and 100 healthy controls (HC). In order to test its reliability, BICAMS was re-administered in a subset of 25 patients. The sample's average age was 43.42 ± 10.17 years old, and average years of schooling were 14.86 ± 2.78. About 74% of the participants were women. The groups did not differ in age, years of schooling, or gender. The MS group performed significantly worse than the HC group across the three neuropsychological tests, yielding the following Cohen's d values: SDMT: .85; CVLT I: .87; and BVMT-R: .40. The mean raw scores for Argentina normative data were as follows: SDMT: 56.71 ± 10.85; CVLT I: 60.88 ± 10.46; and BVMT-R: 23.44 ± 5.84. Finally, test-retest reliability coefficients for each test were as follows: SDMT: r = .95; CVLT I: r = .87; and BVMT-R: r = .82. This BICAMS version is reliable and useful as a monitoring tool for identifying MS patients with cognitive impairment.

  15. Perceiving numbers does not cause automatic shifts of spatial attention.

    PubMed

    Fattorini, Enrico; Pinto, Mario; Rotondaro, Francesca; Doricchi, Fabrizio

    2015-12-01

    It is frequently assumed that the brain codes number magnitudes according to an inherent left-to-right spatial organization. In support of this hypothesis it has been reported that in humans, perceiving small numbers induces automatic shifts of attention toward the left side of space whereas perceiving large numbers automatically shifts attention to the right side of space (i.e., Attentional SNARC: Att-SNARC; Fischer, Castel, Dodd, & Pratt, 2003). Nonetheless, the Att-SNARC has been often not replicated and its reliability never tested. To ascertain whether the mere perception of numbers causes shifts of spatial attention or whether number-space interaction takes place at a different stage of cognitive processing, we re-assessed the consistency and reliability of the Att-SNARC and investigated its role in the production of SNARC effects in Parity Judgement (PJ) and Magnitude Comparison (MC) tasks. In a first study in 60 participants, we found no Att-SNARC, despite finding strong PJ- and MC-SNARC effects. No correlation was present between the Att-SNARC and the SNARC. Split-half tests showed no reliability of the Att-SNARC and high reliability of the PJ- and MC-SNARC. In a second study, we re-assessed the Att-SNARC and tested its direct influence on a MC-SNARC task with laterally presented targets. No Att-SNARC and no influence of the Att-SNARC on the MC-SNARC were found. Also in this case, the SNARC was reliable whereas the Att-SNARC task was not. Finally, in a third study we observed a significant Att-SNARC when participants were asked to recall the position occupied on a ruler by the numbers presented in each trial: however the Att-SNARC task was not reliable. These results show that perceiving numbers does not cause automatic shifts of spatial attention and that whenever present, these shifts do not modulate the SNARC. The same results suggest that numbers have no inherent mental left-to-right organization and that, whenever present, this organization can have both response-related and strategically driven memory-related origins. Nonetheless, response-related factors generate more reliable and stable spatial representations of numbers. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Validity, reliability and responsiveness to change of the Italian palliative care outcome scale: a multicenter study of advanced cancer patients.

    PubMed

    Costantini, Massimo; Rabitti, Elisa; Beccaro, Monica; Fusco, Flavio; Peruselli, Carlo; La Ciura, Pietro; Valle, Alessandro; Suriani, Cinzia; Berardi, Maria Alejandra; Valenti, Danila; Mosso, Felicita; Morino, Piero; Zaninetta, Giovanni; Tubere, Giorgio; Piazza, Massimo; Sofia, Michele; Di Leo, Silvia; Higginson, Irene J

    2016-02-26

    There is an increasing requirement to assess outcomes, but few measures have been tested for advanced medical illness. We aimed to test the validity, reliability and responsiveness of the Palliative care Outcome Scale (POS), and to analyse predictors of change after the transition to palliative care. Phase 1: multicentre, mixed method study comprising cognitive and qualitative interviews with patients and staff, cultural refinement and adaption. Phase 2: consecutive cancer patients on admission to 8 inpatient hospices and 7 home-based teams were asked to complete the POS, the EORTC QLQ-C15-PAL and the FACIT-Sp (T0), to assess internal consistency, convergent and divergent validity. After 6 days (T1) patients and staff completed the POS to assess responsiveness to change (T1-T0), and agreement between self-assessed POS and POS completed by the staff. Finally, we asked hospices an assessment 24-48 h after T1 to assess its reliability (test re-test analysis). Phase I: 209 completed POS questionnaires and 29 cognitive interviews were assessed, revisions made and one item substituted. Phase II: 295 consecutive patients admitted to 15 PCTs were approached, 175 (59.3 %) were eligible, and 150 (85.7 %) consented. Consent was limited by the severity of illness in 40 % patients. We found good convergent validity, with strong and moderate correlations (r ranged 0.5-0.8) between similar items from the POS, the QLQ-C15-PAL and the FACIT-Sp. As hypothesised, the physical function subscale of QLQ-C15-PAL was not correlated with any POS item (r ranged -0.16-0.02). We found acceptable to good test re-test reliability in both versions for 6 items. We found significant clinical improvements during the first week of palliative care in 7/10 items assessed-pain, other symptoms, patient and family anxiety, information, feeling at peace and wasted time. Both the patient self-assessed and professional POS versions are valid and with an acceptable internal consistency. POS detected significant clinical improvements during palliative care, at a time when patients are usually expected to deteriorate. These results suggest that there is room for substantial improvement in the management of patients with advanced disease, across all key domains-symptoms, psychological, information, social and spiritual.

  17. The Recognition Memory Test Examination of ethnic differences and norm validity.

    PubMed

    O'Bryant, Sid E; Hilsabeck, Robin C; McCaffrey, Robert J; Drew Gouvier, Wm

    2003-03-01

    The possibility of racial bias in neuropsychological test materials has received increasing attention in recent years. The purpose of the present study was to investigate whether an own-race recognition bias would provide an advantage for Caucasian participants over African American participants on the Faces subtest of the Recognition Memory Test (RMT). Thirty Caucasian and 30 African American undergraduates completed the RMT, Shipley Institute of Living Scale (SILS), and Symbol Digit Modalities Test (SDMT). No significant group difference was found on RMT Faces. However, mean RMT Faces scores for both groups were below the 10th percentile in spite of average scores on the SDMT and SILS. A second study was conducted to further examine the validity of the RMT norms for this age range (i.e., 18-24) and to provide 2-week test-retest reliabilities. The mean RMT Faces subtest score was 39.78 (10th percentile), and 28% of the sample scored at or below the fifth percentile. Test-retest reliabilities were.63 and.64 for RMT Words and Faces, respectively. Results of these studies suggest that re-examination of the current norms for RMT Faces is warranted for adults aged.

  18. [Spanish version of the Cancer Worry Scale (CWS). Cross cultural adaptation and validity and reliability analysis].

    PubMed

    Cabrera, Esther; Zabalegui, Adelaida; Blanco, Ignacio

    2011-01-15

    The worry for falling ill has been described as a key element in the change of preventive attitudes. Levels of cancer worry not well fitted have been associated with inadequate adherence to preventive strategies. There is not a Spanish validated scale to evaluate the degree of worry for the cancer in our population. The aim of the present study was to perform the cross cultural adaptation and validation of the Cancer Worry Scale described by Lerman. A translation, re-translation of the Cancer Worry Scale to Spanish was done. Validation of the Spanish scale was performed by means of the factorial analysis of principal components with the rotation varimax test in a sample of 200 healthy women with family history of breast cancer. The Escala de Preocupación por el Cáncer (EPC) is the Spanish version of the Cancer Worry Scale and it contains 6 items with a total value ranging from 6 (minimal worry) to 24 (maximum worry). The analysis of content validity demonstrated that the EPC is conceptually equivalent to the original scale. The factorial analysis showed a unique factor that explains 53.07% of the variance confirming the unique dimension. The EPC presented good reliability test - re-test with an Intraclass Correlation Coefficient of 0.777. The Cronbach's alpha was 0.835 for the complete of the scale. The EPC is a validated Spanish scale to measure the cancer worry in healthy individuals, which shows a correct content validity and reliability. Copyright © 2010 Elsevier España, S.L. All rights reserved.

  19. Development of knowledge tests for multi-disciplinary emergency training: a review and an example.

    PubMed

    Sørensen, J L; Thellesen, L; Strandbygaard, J; Svendsen, K D; Christensen, K B; Johansen, M; Langhoff-Roos, P; Ekelund, K; Ottesen, B; Van Der Vleuten, C

    2015-01-01

    The literature is sparse on written test development in a post-graduate multi-disciplinary setting. Developing and evaluating knowledge tests for use in multi-disciplinary post-graduate training is challenging. The objective of this study was to describe the process of developing and evaluating a multiple-choice question (MCQ) test for use in a multi-disciplinary training program in obstetric-anesthesia emergencies. A multi-disciplinary working committee with 12 members representing six professional healthcare groups and another 28 participants were involved. Recurrent revisions of the MCQ items were undertaken followed by a statistical analysis. The MCQ items were developed stepwise, including decisions on aims and content, followed by testing for face and content validity, construct validity, item-total correlation, and reliability. To obtain acceptable content validity, 40 out of originally 50 items were included in the final MCQ test. The MCQ test was able to distinguish between levels of competence, and good construct validity was indicated by a significant difference in the mean score between consultants and first-year trainees, as well as between first-year trainees and medical and midwifery students. Evaluation of the item-total correlation analysis in the 40 items set revealed that 11 items needed re-evaluation, four of which addressed content issues in local clinical guidelines. A Cronbach's alpha of 0.83 for reliability was found, which is acceptable. Content and construct validity and reliability were acceptable. The presented template for the development of this MCQ test could be useful to others when developing knowledge tests and may enhance the overall quality of test development. © 2014 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  20. Translation, cross-cultural adaptation to Brazilian- Portuguese and reliability analysis of the instrument Rapid Entire Body Assessment-REBA

    PubMed Central

    Lamarão, Andressa M.; Costa, Lucíola C. M.; Comper, Maria L. C.; Padula, Rosimeire S.

    2014-01-01

    Background: Observational instruments, such as the Rapid Entire Body Assessment, quickly assess biomechanical risks present in the workplace. However, in order to use these instruments, it is necessary to conduct the translational/cross-cultural adaptation of the instrument and test its measurement properties. Objectives: To perform the translation and the cross-cultural adaptation to Brazilian-Portuguese and test the reliability of the REBA instrument. Method: The procedures of translation and cross-cultural adaptation to Brazilian-Portuguese were conducted following proposed guidelines that involved translation, synthesis of translations, back translation, committee review and testing of the pre-final version. In addition, reliability and the intra- and inter-rater percent agreement were obtained with the Linear Weighted Kappa Coefficient that was associated with the 95% Confidence Interval and the cross tabulation 2×2. Results : The procedures for translation and adaptation were adequate and the necessary adjustments were conducted on the instrument. The intra- and inter-rater reliability showed values of 0.104 to 0.504, respectively, ranging from very poor to moderate. The percentage agreement values ranged from 5.66% to 69.81%. The percentage agreement was closer to 100% at the item 'upper arm' (69.81%) for the Intra-rater 1 and at the items 'legs' and 'upper arm' for the Intra-rater 2 (62.26%). Conclusions: The processes of translation and cross-cultural adaptation were conducted on the REBA instrument and the Brazilian version of the instrument was obtained. However, despite the reliability of the tests used to correct the translated and adapted version, the reliability values are unacceptable according to the guidelines standard, indicating that the reliability must be re-evaluated. Therefore, caution in the interpretation of the biomechanical risks measured by this instrument should be taken. PMID:25003273

  1. The King-Devick test is a valid and reliable tool for assessing sport-related concussion in Australian football: A prospective cohort study.

    PubMed

    Hecimovich, Mark; King, Doug; Dempsey, Alasdair R; Murphy, Myles

    2018-03-28

    Sport-related concussion (SRC) research has focused on impaired oculomotor function. The King-Devick (K-D) test measures oculomotor performance and is reported to identify suboptimal brain function. The use of the K-D test in Australian football (AF), a sport involving body contact and tackling, has not been documented. Therefore, the objective of this study was to determine the test-retest reliability and diagnostic accuracy of the K-D test on a sub-elite AF team. Prospective cohort study METHODS: In total, 22 male players (19.6+2.3 years) were tested and re-tested on the K-D test. Those suspected of having a SRC secondary to a significant head impact were tested. Randomly selected additional players without SRC were assessed for comparison. There were observable learning effects between the first and second baseline testing (48 vs. 46s). The ICC for the first and second baseline tests was 0.91. Post-match test times were longer than the baseline times for players with SRC (n=7) (-1.9s; z=-5.08; p<0.0001). Players tested with no signs of SRC (n=13) had an improvement in time when compared with their baseline score (3.0s; z=-4.38; p<0.0001). The overall sensitivity was 0.98, specificity 0.96, and a kappa of κ=0.94. The positive likelihood ratio was 11.6 and the positive predictive value was 89.0%. This study supports the use of the K-D test due to its test-retest reliability, high sensitivity and specificity, and fast and simple use that is ideal for sports medicine professionals to make quick judgement on management and playability. Copyright © 2018 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  2. Personality traits in companion dogs-Results from the VIDOPET.

    PubMed

    Turcsán, Borbála; Wallis, Lisa; Virányi, Zsófia; Range, Friederike; Müller, Corsin A; Huber, Ludwig; Riemer, Stefanie

    2018-01-01

    Individual behavioural differences in pet dogs are of great interest from a basic and applied research perspective. Most existing dog personality tests have specific (practical) goals in mind and so focused only on a limited aspect of dogs' personality, such as identifying problematic (aggressive or fearful) behaviours, assessing suitability as working dogs, or improving the results of adoption. Here we aimed to create a comprehensive test of personality in pet dogs that goes beyond traditional practical evaluations by exposing pet dogs to a range of situations they might encounter in everyday life. The Vienna Dog Personality Test (VIDOPET) consists of 15 subtests and was performed on 217 pet dogs. A two-step data reduction procedure (principal component analysis on each subtest followed by an exploratory factor analysis on the subtest components) yielded five factors: Sociability-obedience, Activity-independence, Novelty seeking, Problem orientation, and Frustration tolerance. A comprehensive evaluation of reliability and validity measures demonstrated excellent inter- and intra-observer reliability and adequate internal consistency of all factors. Moreover the test showed good temporal consistency when re-testing a subsample of dogs after an average of 3.8 years-a considerably longer test-retest interval than assessed for any other dog personality test, to our knowledge. The construct validity of the test was investigated by analysing the correlations between the results of video coding and video rating methods and the owners' assessment via a dog personality questionnaire. The results demonstrated good convergent as well as discriminant validity. To conclude, the VIDOPET is not only a highly reliable and valid tool for measuring dog personality, but also the first test to show consistent behavioural traits related to problem solving ability and frustration tolerance in pet dogs.

  3. Personality traits in companion dogs—Results from the VIDOPET

    PubMed Central

    Wallis, Lisa; Virányi, Zsófia; Range, Friederike; Müller, Corsin A.; Huber, Ludwig; Riemer, Stefanie

    2018-01-01

    Individual behavioural differences in pet dogs are of great interest from a basic and applied research perspective. Most existing dog personality tests have specific (practical) goals in mind and so focused only on a limited aspect of dogs’ personality, such as identifying problematic (aggressive or fearful) behaviours, assessing suitability as working dogs, or improving the results of adoption. Here we aimed to create a comprehensive test of personality in pet dogs that goes beyond traditional practical evaluations by exposing pet dogs to a range of situations they might encounter in everyday life. The Vienna Dog Personality Test (VIDOPET) consists of 15 subtests and was performed on 217 pet dogs. A two-step data reduction procedure (principal component analysis on each subtest followed by an exploratory factor analysis on the subtest components) yielded five factors: Sociability-obedience, Activity-independence, Novelty seeking, Problem orientation, and Frustration tolerance. A comprehensive evaluation of reliability and validity measures demonstrated excellent inter- and intra-observer reliability and adequate internal consistency of all factors. Moreover the test showed good temporal consistency when re-testing a subsample of dogs after an average of 3.8 years—a considerably longer test-retest interval than assessed for any other dog personality test, to our knowledge. The construct validity of the test was investigated by analysing the correlations between the results of video coding and video rating methods and the owners’ assessment via a dog personality questionnaire. The results demonstrated good convergent as well as discriminant validity. To conclude, the VIDOPET is not only a highly reliable and valid tool for measuring dog personality, but also the first test to show consistent behavioural traits related to problem solving ability and frustration tolerance in pet dogs. PMID:29634747

  4. Test-retest reliability of the diagnosis of schizoaffective disorder in childhood and adolescence - A systematic review and meta-analysis.

    PubMed

    Salamon, Sarah; Santelmann, Hanno; Franklin, Jeremy; Baethge, Christopher

    2018-04-01

    Reliability of schizoaffective disorder (SAD) diagnoses is low in adults but unclear in children and adolescents (CAD). We estimate the test-retest reliability of SAD and its key differential diagnoses (schizophrenia, bipolar disorder, and unipolar depression). Systematic literature search of Medline, Embase, and PsycInfo for studies on test-retest reliability of SAD, in CAD. Cohen's kappa was extracted from studies. We performed meta-analysis for kappa, including subgroup and sensitivity analysis (PROSPERO protocol: CRD42013006713). Out of > 4000 records screened, seven studies were included. We estimated kappa values of 0.27 [95%-CI: 0.07 0.47] for SAD, 0.56 [0.29; 0.83] for schizophrenia, 0.64 [0.55; 0.74] for bipolar disorder, and 0.66 [0.52; 0.81] for unipolar depression. In 5/7 studies kappa of SAD was lower than that of schizophrenia; similar trends emerged for bipolar disorder (4/5) and unipolar depression (2/3). Estimates of positive agreement of SAD diagnoses supported these results. The number of studies and patients included is low. The point-estimate of the test-retest reliability of schizoaffective disorder is only fair, and lower than that of its main differential diagnoses. All kappa values under study were lower in children and adolescents samples than those reported for adults. Clinically, schizoaffective disorder should be diagnosed in strict adherence to the operationalized criteria and ought to be re-evaluated regularly. Should larger studies confirm the insufficient reliability of schizoaffective disorder in children and adolescents, the clinical value of the diagnosis is highly doubtful. Copyright © 2017. Published by Elsevier B.V.

  5. Reliability of a computer and Internet survey (Computer User Profile) used by adults with and without traumatic brain injury (TBI).

    PubMed

    Kilov, Andrea M; Togher, Leanne; Power, Emma

    2015-01-01

    To determine test-re-test reliability of the 'Computer User Profile' (CUP) in people with and without TBI. The CUP was administered on two occasions to people with and without TBI. The CUP investigated the nature and frequency of participants' computer and Internet use. Intra-class correlation coefficients and kappa coefficients were conducted to measure reliability of individual CUP items. Descriptive statistics were used to summarize content of responses. Sixteen adults with TBI and 40 adults without TBI were included in the study. All participants were reliable in reporting demographic information, frequency of social communication and leisure activities and computer/Internet habits and usage. Adults with TBI were reliable in 77% of their responses to survey items. Adults without TBI were reliable in 88% of their responses to survey items. The CUP was practical and valuable in capturing information about social, leisure, communication and computer/Internet habits of people with and without TBI. Adults without TBI scored more items with satisfactory reliability overall in their surveys. Future studies may include larger samples and could also include an exploration of how people with/without TBI use other digital communication technologies. This may provide further information on determining technology readiness for people with TBI in therapy programmes.

  6. Cross-Cultural Adaptation, Reliability and Validity Study of the Persian Version of the Clinical COPD Questionnaire.

    PubMed

    Hasanpour, Neda; Attarbashi Moghadam, Behrouz; Sami, Ramin; Tavakol, Kamran

    2016-08-01

    The clinical COPD questionnaire (CCQ) has been developed to measure the health status of COPD patients. The aim of this study was to translate CCQ into the Persian language and assess the validity and reliability of the translated version. We used a forward-backward procedure to translate the questionnaire. In a cross-sectional study 100 COPD patients and 50 healthy subjects over 40 years old were selected to assess the reliability and construct validity of the instrument. The face and content validity were used for the questionnaire validity. Validity was examined in a population of patients with COPD, using the Persian validated version of the St George's Respiratory Questionnaire (PSGRQ). In order to assess the questionnaire's reliability, the Intraclass correlation coefficient (ICC) and Cronbach's alpha were calculated. Test-retest reliability was tested by re-administering the Persian version of the CCQ (PCCQ) after 1 week. Test-retest carry out of data demonstrates that the PCCQ has excellent reliability (ICC for all 3 domains were higher than 0.9). Internal consistency was found by Cronbach's alpha to be 0.96, 0.94, 0.97, and 0.98 for the symptom, mental state, functional state and total scores respectively. In addition, the correlation between the components of PCCQ and PSGRQ showed satisfactory construct validity. Analyzing the data from healthy subjects and patients divulged that the PCCQ has acceptable discriminant validity. In general, the PCCQ had satisfactory reliability and validity for assessing health-related quality of life status of Iranian COPD patients.

  7. Predicting success in the treatment of psychopaths.

    PubMed

    Copas, J B; Whiteley, J S

    1976-10-01

    Factors from the social history of male psychopaths were examined in relation to their success or failure as measured by re-convictions of psychiatric hospital re-admissions 2-3 years after treatment at Henderson Hospital. From these data a weighted prediction formula was calculated and was tested out on a further cohort of patients. As a prediction instrument it was found to be reliable to a degree of significance just above the 1 per cent level. Other aspects of the subsequent career of treated patients are noted, in particular a tendency to early but often short-lived relapse and then longer standing success.

  8. Simulation of launch and re-entry acceleration profiles for testing of shuttle and unmanned microgravity research payloads

    NASA Astrophysics Data System (ADS)

    Cassanto, J. M.; Ziserman, H. I.; Chapman, D. K.; Korszun, Z. R.; Todd, P.

    Microgravity experiments designed for execution in Get-Away Special canisters, Hitchhiker modules, and Reusable Re-entry Satellites will be subjected to launch and re-entry accelerations. Crew-dependent provisions for preventing acceleration damage to equipment or products will not be available for these payloads during flight; therefore, the effects of launch and re-entry accelerations on all aspects of such payloads must be evaluated prior to flight. A procedure was developed for conveniently simulating the launch and re-entry acceleration profiles of the Space Shuttle (3.3 and 1.7 × g maximum, respectively) and of two versions of NASA's proposed materials research Re-usable Re-entry Satellite (8 × g maximum in one case and 4 × g in the other). By using the 7 m centrifuge of the Gravitational Plant Physiology Laboratory in Philadelphia it was found possible to simulate the time dependence of these 5 different acceleration episodes for payload masses up to 59 kg. A commercial low-cost payload device, the “Materials Dispersion Apparatus” of Instrumentation Technology Associates was tested for (1) integrity of mechanical function, (2) retention of fluid in its compartments, and (3) integrity of products under simulated re-entry g-loads. In particular, the sharp rise from 1 g to maximum g-loading that occurs during re-entry in various unmanned vehicles was successfully simulated, conditions were established for reliable functioning of the MDA, and crystals of 5 proteins suspended in compartments filled with mother liquor were subjected to this acceleration load.

  9. Reliability of the sub-components of the instrumented timed up and go test in ambulatory children with traumatic brain injury and typically developed controls.

    PubMed

    Newman, Mark A; Hirsch, Mark A; Peindl, Richard D; Habet, Nahir A; Tsai, Tobias J; Runyon, Michael S; Huynh, Toan; Zheng, Nigel

    2018-06-01

    Studies have evaluated the test-re-test reliability of subcomponents of the timed up and-go test in adults by using body-worn inertial sensors. However, studies in children have not been reported in the literature. To evaluate the within-session reliability of subcomponents of a newly developed electronically augmented timed 'upand-go' test (EATUG) in ambulatory children with traumatic brain injury (TBI) and children with typical development (TD). The timed up and go test was administered to twelve consecutive ambulatory children with moderate to severe TBI (6 males and 6 females, age 10.5 ± 1.5 years, range 8-13 years, during inpatient rehabilitation at 27.0 ± 11.8 days following injury) and 10 TD age and sex-matched children (5 males and 5 females, 10.4 ± 1.3 years, range 8-11 years). Participants wore a single chest-mounted inertial measurement sensor package with custom software that measured angular and acceleration velocity and torso flexion and extension angles, while they performed 6 trials of the EATUG test. Measures were derived from the overall time to complete the TUG test, angular velocity and angular displacement data for torso flexion and extension during sit-to-stand and stand-to-sit segments and both mean and peak angular velocities for two turning segments (i.e. turning around a cone and turning-before-sitting). Within-session reliability of the subcomponents of the TUG test for children with TBI assessed by the intra-class correlation coefficient was ICC (1,1) = 0.84, (range 0.82-0.96), and for TD children ICC (1,1) = 0.73, (range 0.53-0.89). Scores on Total Time, maximum torso flexion/extension angle and peak flexion angular velocity during sit-tostand, and peak turn angular velocity for both turns around the cone and turns before sitting were lower for children with TBI than for TD children (p ≤ 0.05). The EATUG test is a reliable measure of physical function in children with TBI who are being discharged from inpatient rehabilitation. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. THE INTRA- AND INTER-RATER RELIABILITY OF THE SOCCER INJURY MOVEMENT SCREEN (SIMS).

    PubMed

    McCunn, Robert; Aus der Fünten, Karen; Govus, Andrew; Julian, Ross; Schimpchen, Jan; Meyer, Tim

    2017-02-01

    The growing volume of movement screening research reveals a belief among practitioners and researchers alike that movement quality may have an association with injury risk. However, existing movement screening tools have not considered the sport-specific movement and injury patterns relevant to soccer. The present study introduces the Soccer Injury Movement Screen (SIMS), which has been designed specifically for use within soccer. Furthermore, the purpose of the present study was to assess the intra- and inter-rater reliability of the SIMS and determine its suitability for use in further research. The study utilized a test-retest design to discern reliablility. Twenty-five (11 males, 14 females) healthy, recreationally active university students (age 25.5 ± 4.0 years, height 171 ± 9 cm, weight 64.7 ± 12.6 kg) agreed to participate. The SIMS contains five sub-tests: the anterior reach, single-leg deadlift, in-line lunge, single-leg hop for distance and tuck jump. Each movement was scored out of 10 points and summed to produce a composite score out of 50. The anterior reach and single-leg hop for distance were scored in real-time while the remaining tests were filmed and scored retrospectively. Three raters conducted the SIMS with each participant on three occasions separated by an average of three and a half days (minimum one day, maximum seven days). Rater 1 re-scored the filmed movements for all participants on all occasions six months later to establish the 'pure' intra-rater (intra-occasion) reliability for those movements. Intraclass correlation coefficient (ICC) values for intra- and inter-rater composite score reliability ranged from 0.66-0.72 and 0.79-0.86 respectively. Weighted kappa values representing the intra- and inter-rater reliability of the individual sub-tests ranged from 0.35-0.91 indicating fair to almost perfect agreement. Establishing the reliability of the SIMS is a prerequisite for further research seeking to investigate the relationship between test score and subsequent injury. The present results indicate acceptable reliability for this purpose; however, room for further development of the intra-rater reliability exists for some of the individual sub-tests. 2b.

  11. THE INTRA- AND INTER-RATER RELIABILITY OF THE SOCCER INJURY MOVEMENT SCREEN (SIMS)

    PubMed Central

    aus der Fünten, Karen; Govus, Andrew; Julian, Ross; Schimpchen, Jan; Meyer, Tim

    2017-01-01

    Background/purpose The growing volume of movement screening research reveals a belief among practitioners and researchers alike that movement quality may have an association with injury risk. However, existing movement screening tools have not considered the sport-specific movement and injury patterns relevant to soccer. The present study introduces the Soccer Injury Movement Screen (SIMS), which has been designed specifically for use within soccer. Furthermore, the purpose of the present study was to assess the intra- and inter-rater reliability of the SIMS and determine its suitability for use in further research. Methods The study utilized a test-retest design to discern reliablility. Twenty-five (11 males, 14 females) healthy, recreationally active university students (age 25.5 ± 4.0 years, height 171 ± 9 cm, weight 64.7 ± 12.6 kg) agreed to participate. The SIMS contains five sub-tests: the anterior reach, single-leg deadlift, in-line lunge, single-leg hop for distance and tuck jump. Each movement was scored out of 10 points and summed to produce a composite score out of 50. The anterior reach and single-leg hop for distance were scored in real-time while the remaining tests were filmed and scored retrospectively. Three raters conducted the SIMS with each participant on three occasions separated by an average of three and a half days (minimum one day, maximum seven days). Rater 1 re-scored the filmed movements for all participants on all occasions six months later to establish the ‘pure’ intra-rater (intra-occasion) reliability for those movements. Results Intraclass correlation coefficient (ICC) values for intra- and inter-rater composite score reliability ranged from 0.66-0.72 and 0.79-0.86 respectively. Weighted kappa values representing the intra- and inter-rater reliability of the individual sub-tests ranged from 0.35-0.91 indicating fair to almost perfect agreement. Conclusions Establishing the reliability of the SIMS is a prerequisite for further research seeking to investigate the relationship between test score and subsequent injury. The present results indicate acceptable reliability for this purpose; however, room for further development of the intra-rater reliability exists for some of the individual sub-tests. Level of evidence 2b PMID:28217416

  12. LATERAL CONTROL IN A DRIVING SIMULATOR: CORRELATIONS WITH NEUROPSYCHOLOGICAL TESTS AND ON-ROAD SAFETY ERRORS

    PubMed Central

    Johnson, Amy; Dawson, Jeffrey; Rizzo, Matthew

    2012-01-01

    Summary Driving simulators provide precise information on vehicular position at high capture rates. To analyze such data, we have previously proposed a time series model that reduces lateral position data into several parameters for measuring lateral control, and have shown that these parameters can detect differences between neurologically impaired and healthy drivers (Dawson et al, 2010a). In this paper, we focus on the “re-centering” parameter of this model, and test whether the parameter estimates are associated with off-road neuropsychological tests and/or with on-road safety errors. We assessed such correlations in 127 neurologically healthy drivers, ages 40 to 89. We found that our re-centering parameter had significant correlations with five neuropsychological tests: Judgment of Line Orientation (r = 0.38), Block Design (r = 0.27), Contrast Sensitivity (r = 0.31), Near Visual Acuity (r = -0.26), and Grooved Pegboard (r = -0.25). We also found that our re-centering parameter was associated with on-road safety errors at stop signs (r = -0.34) and on-road safety errors during turns (r = -0.22). These results suggest that our re-centering parameter may be a useful tool for measuring and monitoring ability to maintain vehicular lateral control. As GPS-based technology continues to improve in precision and reliability to measure vehicular positioning, our time-series model may potentially be applied as an automated index of driver performance in real world settings that is sensitive to cognitive decline. This work was supported by NIH/NIA awards AG17177, AG15071, and NS044930, and by a scholarship from Nissan Motor Company. PMID:24273756

  13. Feasibility, reliability, and validity of a smartphone based application for the assessment of cognitive function in the elderly.

    PubMed

    Brouillette, Robert M; Foil, Heather; Fontenot, Stephanie; Correro, Anthony; Allen, Ray; Martin, Corby K; Bruce-Keller, Annadora J; Keller, Jeffrey N

    2013-01-01

    While considerable knowledge has been gained through the use of established cognitive and motor assessment tools, there is a considerable interest and need for the development of a battery of reliable and validated assessment tools that provide real-time and remote analysis of cognitive and motor function in the elderly. Smartphones appear to be an obvious choice for the development of these "next-generation" assessment tools for geriatric research, although to date no studies have reported on the use of smartphone-based applications for the study of cognition in the elderly. The primary focus of the current study was to assess the feasibility, reliability, and validity of a smartphone-based application for the assessment of cognitive function in the elderly. A total of 57 non-demented elderly individuals were administered a newly developed smartphone application-based Color-Shape Test (CST) in order to determine its utility in measuring cognitive processing speed in the elderly. Validity of this novel cognitive task was assessed by correlating performance on the CST with scores on widely accepted assessments of cognitive function. Scores on the CST were significantly correlated with global cognition (Mini-Mental State Exam: r = 0.515, p<0.0001) and multiple measures of processing speed and attention (Digit Span: r = 0.427, p<0.0001; Trail Making Test: r = -0.651, p<0.00001; Digit Symbol Test: r = 0.508, p<0.0001). The CST was not correlated with naming and verbal fluency tasks (Boston Naming Test, Vegetable/Animal Naming) or memory tasks (Logical Memory Test). Test re-test reliability was observed to be significant (r = 0.726; p = 0.02). Together, these data are the first to demonstrate the feasibility, reliability, and validity of using a smartphone-based application for the purpose of assessing cognitive function in the elderly. The importance of these findings for the establishment of smartphone-based assessment batteries of cognitive and motor function in the elderly is discussed.

  14. Reliability and validity of a smartphone pulse rate application for the assessment of resting and elevated pulse rate.

    PubMed

    Mitchell, Katy; Graff, Megan; Hedt, Corbin; Simmons, James

    2016-08-01

    Purpose/hypothesis: This study was designed to investigate the test-retest reliability, concurrent validity, and the standard error of measurement (SEm) of a pulse rate assessment application (Azumio®'s Instant Heart Rate) on both Android® and iOS® (iphone operating system) smartphones as compared to a FT7 Polar® Heart Rate monitor. Number of subjects: 111. Resting (sitting) pulse rate was assessed twice and then the participants were asked to complete a 1-min standing step test and then immediately re-assessed. The smartphone assessors were blinded to their measurements. Test-retest reliability (intraclass correlation coefficient [ICC 2,1] and 95% confidence interval) for the three tools at rest (time 1/time 2): iOS® (0.76 [0.67-0.83]); Polar® (0.84 [0.78-0.89]); and Android® (0.82 [0.75-0.88]). Concurrent validity at rest time 2 (ICC 2,1) with the Polar® device: IOS® (0.92 [0.88-0.94]) and Android® (0.95 [0.92-0.96]). Concurrent validity post-exercise (time 3) (ICC) with the Polar® device: iOS® (0.90 [0.86-0.93]) and Android® (0.94 [0.91-0.96]). The SEm values for the three devices at rest: iOS® (5.77 beats per minute [BPM]), Polar® (4.56 BPM) and Android® (4.96 BPM). The Android®, iOS®, and Polar® devices showed acceptable test-retest reliability at rest and post-exercise. Both the smartphone platforms demonstrated concurrent validity with the Polar® at rest and post-exercise. The Azumio® Instant Heart Rate application when used by either platform appears to be a reliable and valid tool to assess pulse rate in healthy individuals.

  15. A Re-programmable Platform for Dynamic Burn-in Test of Xilinx Virtexll 3000 FPGA for Military and Aerospace Applications

    NASA Technical Reports Server (NTRS)

    Roosta, Ramin; Wang, Xinchen; Sadigursky, Michael; Tracton, Phil

    2004-01-01

    Field Programmable Gate Arrays (FPGA) have played increasingly important roles in military and aerospace applications. Xilinx SRAM-based FPGAs have been extensively used in commercial applications. They have been used less frequently in space flight applications due to their susceptibility to single-event upsets. Reliability of these devices in space applications is a concern that has not been addressed. The objective of this project is to design a fully programmable hardware/software platform that allows (but is not limited to) comprehensive static/dynamic burn-in test of Virtex-II 3000 FPGAs, at speed test and SEU test. Conventional methods test very few discrete AC parameters (primarily switching) of a given integrated circuit. This approach will test any possible configuration of the FPGA and any associated performance parameters. It allows complete or partial re-programming of the FPGA and verification of the program by using read back followed by dynamic test. Designers have full control over which functional elements of the FPGA to stress. They can completely simulate all possible types of configurations/functions. Another benefit of this platform is that it allows collecting information on elevation of the junction temperature as a function of gate utilization, operating frequency and functionality. A software tool has been implemented to demonstrate the various features of the system. The software consists of three major parts: the parallel interface driver, main system procedure and a graphical user interface (GUI).

  16. Social Support and Peer Norms Scales for Physical Activity in Adolescents

    PubMed Central

    Ling, Jiying; Robbins, Lorraine B.; Resnicow, Ken; Bakhoya, Marion

    2015-01-01

    Objectives To evaluate psychometric properties of a Social Support and Peer Norms Scale in 5th-7th grade urban girls. Methods Baseline data from 509 girls and test-retest data from another 94 girls in the Midwestern US were used. Results Cronbach's alpha was .83 for the Social Support Scale and .72 for the Peer Norms Scale, whereas test-re-test reliability was .78 for both scales. Exploratory factor analysis suggested a single factor structure for the Social Support Scale, and a 3-factor structure for the Peer Norms Scale. Social support was correlated with accelerometer-measured physical activity (r = .13, p = .006), and peer norms (r = .50, p < .0001). Conclusions Both scales have adequate psychometric properties. PMID:25207514

  17. Testing of a Wireless Sensor System for Instrumented Thermal Protection Systems

    NASA Technical Reports Server (NTRS)

    Kummer, Allen T.; Weir, Erik D.; Morris, Trey J.; Friedenberger, Corey W.; Singh, Aseem; Capuro, Robert M.; Bilen, Sven G.; Fu, Johnny; Swanson, Gregory T.; Hash, David B.

    2011-01-01

    Funded by NASA's Constellation Universities Institutes Project (CUIP), we have been developing and testing a system to wirelessly power and collect data from sensors on space platforms in general and, in particular, the harsh environment of spacecraft re-entry. The elimination of wires and associated failures such as chafing, sparking, ageing, and connector issues can increase reliability and design flexibility while reducing costs. These factors present an appealing case for the pursuit of wireless solutions for harsh environments, particularly for their use in space and on spacecraft. We have designed and built a prototype wireless sensor system. The system, with capabilities similar to that of a wired sensor system, was tested in NASA Ames Research Center s Aerodynamic Heating Facility and Interaction Heating Facility. This paper discusses the overall development effort, testing results, as well as future directions.

  18. 76 FR 31860 - Anthropomorphic Test Devices; Hybrid III Test Dummy, ES-2re Side Impact Crash Test Dummy

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-02

    ... [Docket No. NHTSA-2010-0146] RIN 2127-AK64 Anthropomorphic Test Devices; Hybrid III Test Dummy, ES-2re Side Impact Crash Test Dummy AGENCY: National Highway Traffic Safety Administration (NHTSA), Department..., 2008, concerning a 50th percentile adult male side crash test dummy called the ``ES-2re'' test dummy...

  19. Psychometric evaluation of a daily gastro-oesophageal reflux disease symptom measure.

    PubMed

    Bytzer, Peter; Reimer, Christina; Smith, Gary; Anatchkova, Milena D; Hsieh, Ray; Wilkinson, Joanne; Thomas, S Jane; Lenderking, William R

    2017-03-01

    The objective of this study was to evaluate the validity of the Heartburn Reflux Dyspepsia Questionnaire (HRDQ), a newly developed measure of gastro-oesophageal reflux disease (GORD) symptoms. Specifically, the HRDQ was developed for patients, who still experience symptoms with proton pump inhibitor (PPI) treatment. The psychometric properties of HRDQ were evaluated based on data from two clinical trials of patients with GORD with a partial response to PPIs, one from the UK and one from Denmark and Germany. The HRDQ had good internal consistency (Cronbach's alpha range .83-.88) and test-retest reliability (intraclass correlation coefficient range .71-.90). Convergent and discriminant validity were supported by high correlations with ReQuest™ and ability to differentiate between groups based on ReQuest™ cut-off values. Responsiveness of HRDQ was demonstrated by moderate to high correlations with ReQuest™ change scores and time with symptoms. An HRDQ cut-off value of 0.70 for definition of 'bad day' was also evaluated. Based on existing evidence, the HRDQ is a valid and reliable measure of GORD symptoms that can be used as a study outcome in clinical trials.

  20. 75 FR 5931 - Anthropomorphic Test Devices; Hybrid III Test Dummy, ES-2re Side Impact Crash Test Dummy

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-05

    ... [Docket No. NHTSA-2009-0194] RIN 2127-AK64 Anthropomorphic Test Devices; Hybrid III Test Dummy, ES-2re Side Impact Crash Test Dummy AGENCY: National Highway Traffic Safety Administration (NHTSA), Department... adopted specifications and qualification requirements for a new crash test dummy called the ``ES- 2re...

  1. Hepatitis C testing and re-testing among people attending sexual health services in Australia, and hepatitis C incidence among people with human immunodeficiency virus: analysis of national sentinel surveillance data.

    PubMed

    Boettiger, David C; Law, Matthew G; Dore, Gregory J; Guy, Rebecca; Callander, Denton; Donovan, Basil; O'Connor, Catherine C; Fairley, Christopher K; Hellard, Margaret; Matthews, Gail

    2017-12-01

    Direct acting antivirals are expected to drastically reduce the burden of hepatitis C virus (HCV) in people living with Human Immunodeficiency Virus (HIV). However, rates of HCV testing, re-testing and incident infection in this group remain uncertain in Australia. We assessed trends in HCV testing, re-testing and incident infection among HIV-positive individuals, and evaluated factors associated with HCV re-testing and incident infection. The study population consisted of HIV-positive individuals who visited a sexual health service involved in the Australian Collaboration for Coordinated Enhanced Sentinel Surveillance (ACCESS) between 2007 and 2015. Poisson regression was used to assess trends and to evaluate factors associated with HCV re-testing and incident HCV infection. There were 9227 HIV-positive individuals included in our testing rate analysis. Of 3799 HIV-positive/HCV-negative people that attended an ACCESS sexual health service more than once, 2079 (54.7%) were re-tested for HCV and were therefore eligible for our incidence analysis. The rate of HCV testing increased from 17.1 to 51.4 tests per 100 patient years between 2007 and 2015 (p for trend <0.01). Over the same period, HCV re-testing rates increased from 23.9 to 79.7 tests per 100 person years (p for trend <0.01). A clear increase in testing and re-testing began after 2011. Patients who identified as men who have sex with men and those with a history of injecting drug use experienced high rates of HCV re-testing over the course of the study period. Among those who re-tested, 157 incident HCV infections occurred at a rate of 2.5 events per 100 person years. Between 2007 and 2009, 2010-2011, 2012-2013 and 2014-2015, rates of incident HCV were 0.8, 1.5, 3.9 and 2.7 events per 100 person years, respectively (p for trend <0.01). Incident HCV was strongly associated with a history of injecting drug use. High rates of HCV testing and re-testing among HIV-positive individuals in Australia will assist strategies to achieve HCV elimination through rapid treatment scale up. Continued monitoring of HCV incidence in this population is essential for guiding both HCV prevention and treatment strategies.

  2. High reliability sheathed, beryllia insulated, tungsten-rhenium alloy thermocouple assemblies; their fabrication and EMF stability

    NASA Technical Reports Server (NTRS)

    Burns, G. W.; Hurst, W. S.; Scroger, M. G.

    1974-01-01

    Tantalum sheathed, BeO insulated, W-3% Re/W-25% Re thermocouple assemblies were fabricated and their emf drift determined during 2059 hours of exposure at 2073 K in a gaseous helium environment. The sheathed thermocouple assemblies were constructed from aged thermoelements, specially heat-treated BeO insulators, and specially cleaned and etched tantalum sheaths. Their thermal emf drifts ranged from the equivalent of only -0.3 to -0.8 K drift per 1000 hours of exposure at 2073 K. No evidence of any gross chemical attack or degradation of the component materials was found. The emf drift and material behavior of some unsheathed, BeO insulated, W-3% Re/W-25% Re thermocouples at 2250 and 2400 K were also determined. Unsheathed thermocouples tested in an argon environment at 2250 K for 1100 hours and at 2400 K for 307 hours exhibited changes in thermal emf that typically ranged from the equivalent of a few degrees K to as much as +11 K. Post-test examinations of these thermocouples revealed some undesirable material degradation and interaction which included erosion of the BeO insulators and contamination of the thermoelements by tantalum from the tantalum blackbody enclosure in which the thermocouples were contained.

  3. An Overview of Long Duration Sodium Heat Pipe Tests

    NASA Astrophysics Data System (ADS)

    Rosenfeld, John H.; Ernst, Donald M.; Lindemuth, James E.; Sanzi, James L.; Geng, Steven M.; Zuo, Jon

    2004-02-01

    High temperature heat pipes are being evaluated for use in energy conversion applications such as fuel cells, gas turbine re-combustors, and Stirling cycle heat sources; with the resurgence of space nuclear power, additional applications include reactor heat removal elements and radiator elements. Long operating life and reliable performance are critical requirements for these applications. Accordingly long-term materials compatibility is being evaluated through the use of high temperature life test heat pipes. Thermacore, Inc. has carried out several sodium heat pipe life tests to establish long term operating reliability. Four sodium heat pipes have recently demonstrated favorable materials compatibility and heat transport characteristics at high operating temperatures in air over long time periods. A 316L stainless steel heat pipe with a sintered porous nickel wick structure and an integral brazed cartridge heater has successfully operated at 650C to 700C for over 115,000 hours without signs of failure. A second 316L stainless steel heat pipe with a specially-designed Inconel 601 rupture disk and a sintered nickel powder wick has demonstrated over 83,000 hours at 600C to 650C with similar success. A representative one-tenth segment Stirling Space Power Converter heat pipe with an Inconel 718 envelope and a stainless steel screen wick has operated for over 41,000 hours at nearly 700C. A hybrid (i.e. gas-fired and solar) heat pipe with a Haynes 230 envelope and a sintered porous nickel wick structure was operated for about 20,000 hours at nearly 700C without signs of degradation. These life test results collectively have demonstrated the potential for high temperature heat pipes to serve as reliable energy conversion system components for power applications that require long operating lifetime with high reliability. Detailed design specifications, operating history, and test results are described for each of these sodium heat pipes. Lessons learned and future life test plans are also discussed.

  4. An Overview of Long Duration Sodium Heat Pipe Tests

    NASA Technical Reports Server (NTRS)

    Rosenfeld, John H.; Ernst, Donald M.; Lindemuth, James E.; Sanzi, James L.; Geng, Steven M.; Zuo, Jon

    2004-01-01

    High temperature heat pipes are being evaluated for use in energy conversion applications such as fuel cells, gas turbine re-combustors, and Stirling cycle heat sources; with the resurgence of space nuclear power, additional applications include reactor heat removal elements and radiator elements. Long operating life and reliable performance are critical requirements for these applications. Accordingly long-term materials compatibility is being evaluated through the use of high temperature life test heat pipes. Thermacore International, Inc., has carried out several sodium heat pipe life tests to establish long term operating reliability. Four sodium heat pipes have recently demonstrated favorable materials compatibility and heat transport characteristics at high operating temperatures in air over long time periods. A 3l6L stainless steel heat pipe with a sintered porous nickel wick structure and an integral brazed cartridge heater has successfully operated at 650 to 700 C for over 115,000 hours without signs of failure. A second 3l6L stainless steel heat pipe with a specially-designed Inconel 60 I rupture disk and a sintered nickel powder wick has demonstrated over 83,000 hours at 600 to 650 C with similar success. A representative one-tenth segment Stirling Space Power Converter heat pipe with an Inconel 718 envelope and a stainless steel screen wick has operated for over 41 ,000 hours at nearly 700 0c. A hybrid (i.e. gas-fired and solar) heat pipe with a Haynes 230 envelope and a sintered porous nickel wick structure was operated for about 20,000 hours at nearly 700 C without signs of degradation. These life test results collectively have demonstrated the potential for high temperature heat pipes to serve as reliable energy conversion system components for power applications that require long operating lifetime with high reliability, Detailed design specifications, operating hi story, and test results are described for each of these sodium heat pipes. Lessons learned and future life test plans are also discussed.

  5. Weighted re-randomization tests for minimization with unbalanced allocation.

    PubMed

    Han, Baoguang; Yu, Menggang; McEntegart, Damian

    2013-01-01

    Re-randomization test has been considered as a robust alternative to the traditional population model-based methods for analyzing randomized clinical trials. This is especially so when the clinical trials are randomized according to minimization, which is a popular covariate-adaptive randomization method for ensuring balance among prognostic factors. Among various re-randomization tests, fixed-entry-order re-randomization is advocated as an effective strategy when a temporal trend is suspected. Yet when the minimization is applied to trials with unequal allocation, fixed-entry-order re-randomization test is biased and thus compromised in power. We find that the bias is due to non-uniform re-allocation probabilities incurred by the re-randomization in this case. We therefore propose a weighted fixed-entry-order re-randomization test to overcome the bias. The performance of the new test was investigated in simulation studies that mimic the settings of a real clinical trial. The weighted re-randomization test was found to work well in the scenarios investigated including the presence of a strong temporal trend. Copyright © 2013 John Wiley & Sons, Ltd.

  6. Development and validation of a tool to assess the physical and social environment associated with physical activity among adults in Sri Lanka.

    PubMed

    De Silva Weliange, Shreenika H; Fernando, Dulitha; Gunatilake, Jagath

    2014-05-03

    Environmental characteristics are known to be associated with patterns of physical activity (PA). Although several validated tools exist, to measure the environment characteristics, these instruments are not necessarily suitable for application in all settings especially in a developing country. This study was carried out to develop and validate an instrument named the "Physical And Social Environment Scale--PASES" to assess the physical and social environmental factors associated with PA. This will enable identification of various physical and social environmental factors affecting PA in Sri Lanka, which will help in the development of more tailored intervention strategies for promoting higher PA levels in Sri Lanka. The PASES was developed using a scientific approach of defining the construct, item generation, analysis of content of items and item reduction. Both qualitative and quantitative methods of key informant interviews, in-depth interviews and rating of the items generated by experts were conducted. A cross sectional survey among 180 adults was carried out to assess the factor structure through principal component analysis. Another cross sectional survey among a different group of 180 adults was carried out to assess the construct validity through confirmatory factor analysis. Reliability was assessed with test re-test reliability and internal consistency using Spearman r and Cronbach's alpha respectively. Thirty six items were selected after the expert ratings and were developed into interviewer administered questions. Exploration of factor structure of the 34 items which were factorable through principal component analysis with Quartimax rotation extracted 8 factors. The 34 item instrument was assessed for construct validity with confirmatory factor analysis which confirmed an 8 factor model (x2 = 339.9, GFI = 0.90). The identified factors were infrastructure for walking, aesthetics and facilities for cycling, vehicular traffic safety, access and connectivity, recreational facilities for PA, safety, social cohesion and social acceptance of PA with the two non-factorable factors, residential density and land use mix. The PASES also showed good test re-test reliability and a moderate level of internal consistency. The PASES is a valid and reliable tool which could be used to assess the physical and social environment associated with PA in Sri Lanka.

  7. Assessing motivation to change in bulimia nervosa: the Bulimia Nervosa Stages of Change Questionnaire.

    PubMed

    Martinez, Esteve; Castro, Josefina; Bigorra, Aitana; Morer, Astrid; Calvo, Rosa; Vila, Montserrat; Toro, Josep; Rieger, Elisabeth

    2007-01-01

    To assess motivation to change in adolescent patients with bulimia nervosa through the Bulimia Nervosa Stages of Change Questionnaire (BNSOCQ), an instrument adapted from the Anorexia Nervosa Stages of Change Questionnaire (ANSOCQ) already validated in anorexic patients. Subjects were 30 bulimia nervosa patients (mean age = 16.3 years) who were receiving treatment at an eating disorders unit. The evaluation instruments were: the BNSOCQ, the Eating Disorders Inventory (EDI-2) and the Beck Depression Inventory (BDI). The BNSOCQ was re-administered 1 week later to evaluate test-retest reliability. The BNSOCQ demonstrated good internal consistency (Cronbach's alpha = 0.94) and one week test-retest reliability (Pearson's r = 0.93). Negative significant correlations were found between the BNSOCQ and several EDI-2 scales (Pearson's r between -0.51 and -0.84) and the BDI (r = -0.74). The study provides initial support for the reliability and validity of the BNSOCQ as a self-report instrument for assessing motivation to change in adolescents with bulimia nervosa. 2006 John Wiley & Sons, Ltd and Eating Disorders Association

  8. The Dichotic Digits difference Test (DDdT): Development, Normative Data, and Test-Retest Reliability Studies Part 1.

    PubMed

    Cameron, Sharon; Glyde, Helen; Dillon, Harvey; Whitfield, Jessica; Seymour, John

    2016-06-01

    The dichotic digits test is one of the most widely used assessment tools for central auditory processing disorder. However, questions remain concerning the impact of cognitive factors on test results. To develop the Dichotic Digits difference Test (DDdT), an assessment tool that could differentiate children with cognitive deficits from children with genuine dichotic deficits based on differential test results. The DDdT consists of four subtests: dichotic free recall (FR), dichotic directed left ear (DLE), dichotic directed right ear (DRE), and diotic. Scores for six conditions are calculated (FR left ear [LE], FR right ear [RE], and FR total, as well as DLE, DRE, and diotic). Scores for four difference measures are also calculated: dichotic advantage, right-ear advantage (REA) FR, REA directed, and attention advantage. Experiment 1 involved development of the DDdT, including error rate analysis. Experiment 2 involved collection of normative and test-retest reliability data. Twenty adults (aged 25 yr 10 mo to 50 yr 7 mo, mean 36 yr 4 mo) took part in the development study; 62 normal-hearing, typically developing, primary-school children (aged 7 yr 1 mo to 11 yr 11 mo, mean 9 yr 4 mo) and 10 adults (aged 25 yr 0 mo to 51 yr 6 mo, mean 34 yr 10 mo) took part in the normative and test-retest reliability study. In Experiment 1, error rate analysis was conducted on the 36 digit-pair combinations of the DDdT. Normative data collected in Experiment 2 were arcsine transformed to achieve a distribution that was closer to a normal distribution and z-scores calculated. Pearson product-moment correlations were used to determine the strength of relationships between DDdT conditions. The development study revealed no significant differences in the adult population between test and retest on any DDdT condition. Error rates on 36 digit pairs ranged from 1.5% to 16.7%. The most and the least error-prone digits were removed before commencement of the normative data study, leaving 25 unique digit pairs. Average z-scores calculated from the arcsine-transformed data collected from the 62 children who took part in the normative data study revealed that FR dichotic processing (LE, RE, and total) was highly correlated with diotic processing (r ranging from 0.5 to 0.6; p < 0.0001). Significant improvements in performance on retest occurred for the FR LE, RE, total, and diotic conditions (p ranging from 0.05 to 0.0004), the conditions that would be expected to improve with practice if the participant's response strategies are better the second time around. The addition of a diotic control task-that shares many response demands with the usual dichotic tasks-opens up the possibility of differentiating children who perform below expectations because of poor dichotic processing skills from those who perform poorly because of impaired attention, memory, or other cognitive abilities. The high correlation between dichotic and diotic performance suggests that factors other than dichotic performance play a substantial role in a child's ability to perform a dichotic listening task. This hypothesis is investigated further in the cognitive correlation study that follows in the companion paper (DDdT Study Part 2; Cameron et al, 2016). American Academy of Audiology.

  9. Reliability of Causality Assessment for Drug, Herbal and Dietary Supplement Hepatoxicity in the Drug-Induced Liver Injury Network (DILIN)

    PubMed Central

    Hayashi, Paul H.; Barnhart, Huiman X.; Fontana, Robert J.; Chalasani, Naga; Davern, Timothy J.; Talwalkar, Jayant A.; Reddy, K. Rajender; Stolz, Andrew A.; Hoofnagle, Jay H.; Rockey, Don C.

    2014-01-01

    Background Due to the lack of objective tests to diagnose drug induced liver injury (DILI), causality assessment is a matter of debate. Expert opinion is often used in research and industry but its test-retest reliability is unknown. Aims To determine the test-retest reliability of the expert opinion process used by the Drug-Induced Liver Injury Network (DILIN) Methods Three DILIN hepatologists adjudicate suspected hepatotoxicity cases to 1 of 5 categories representing levels of likelihood of DILI. Adjudication is based on retrospective assessment of gathered case data that includes prospective follow-up information. One hundred randomly selected DILIN cases were re-assessed using the same processes for initial assessment but by 3 different reviewers in 92% of cases. Results The median time between assessments was 938 days (range: 140–2352). Thirty-one cases involved >1 agent. Weighted kappa statistics for overall case and individual agent category agreement were 0.60 (95% CI: 0.50–0.71) and 0.60 (0.52–0.68), respectively. Overall case adjudications were within one category of each other 93% of the time, while 5% differed by 2 categories and 2% differed by 3 categories. Fourteen-percent crossed the 50% threshold of likelihood due to competing diagnoses or atypical timing between drug exposure and injury. Conclusions The DILIN expert opinion causality assessment method has moderate inter-observer reliability but very good agreement within 1 category. A small but important proportion of cases could not be reliably diagnosed as ≥ 50% likely to be DILI. PMID:24661785

  10. Evaluation of the numeric rating scale for perception of effort during isometric elbow flexion exercise.

    PubMed

    Lampropoulou, Sofia; Nowicky, Alexander V

    2012-03-01

    The aim of the study was to examine the reliability and validity of the numerical rating scale (0-10 NRS) for rating perception of effort during isometric elbow flexion in healthy people. 33 individuals (32 ± 8 years) participated in the study. Three re-test measurements within one session and three weekly sessions were undertaken to determine the reliability of the scale. The sensitivity of the scale following 10 min isometric fatiguing exercise of the elbow flexors as well as the correlation of the effort with the electromyographic (EMG) activity of the flexor muscles were tested. Perception of effort was tested during isometric elbow flexion at 10, 30, 50, 70, 90, and 100% MVC. The 0-10 NRS demonstrated an excellent test-retest reliability [intra class correlation (ICC) = 0.99 between measurements taken within a session and 0.96 between 3 consecutive weekly sessions]. Exploratory curve fitting for the relationship between effort ratings and voluntary force, and underlying EMG showed that both are best described by power functions (y = ax ( b )). There were also strong correlations (range 0.89-0.95) between effort ratings and EMG recordings of all flexor muscles supporting the concurrent criterion validity of the measure. The 0-10 NRS was sensitive enough to detect changes in the perceived effort following fatigue and significantly increased at the level of voluntary contraction used in its assessment (p < 0.001). These findings suggest the 0-10 NRS is a valid and reliable scale for rating perception of effort in healthy individuals. Future research should seek to establish the validity of the 0-10 NRS in clinical settings.

  11. Development and Preliminary Validation of a Comprehensive Questionnaire to Assess Women’s Knowledge and Perception of the Current Weight Gain Guidelines during Pregnancy

    PubMed Central

    Ockenden, Holly; Gunnell, Katie; Giles, Audrey; Nerenberg, Kara; Goldfield, Gary; Manyanga, Taru; Adamo, Kristi

    2016-01-01

    The aim of this study was to develop and validate an electronic questionnaire, the Electronic Maternal Health Survey (EMat Health Survey), related to women’s knowledge and perceptions of the current gestational weight gain guidelines (GWG), as well as pregnancy-related health behaviours. Constructs addressed within the questionnaire include self-efficacy, locus of control, perceived barriers, and facilitators of physical activity and diet, outcome expectations, social environment and health practices. Content validity was examined using an expert panel (n = 7) and pilot testing items in a small sample (n = 5) of pregnant women and recent mothers (target population). Test re-test reliability was assessed among a sample (n = 71) of the target population. Reliability scores were calculated for all constructs (r and intra-class correlation coefficients (ICC)), those with a score of >0.5 were considered acceptable. The content validity of the questionnaire reflects the degree to which all relevant components of excessive GWG risk in women are included. Strong test-retest reliability was found in the current study, indicating that responses to the questionnaire were reliable in this population. The EMat Health Survey adds to the growing body of literature on maternal health and gestational weight gain by providing the first comprehensive questionnaire that can be self-administered and remotely accessed. The questionnaire can be completed in 15–25 min and collects useful data on various social determinants of health and GWG as well as associated health behaviours. This online tool may assist researchers by providing them with a platform to collect useful information in developing and tailoring interventions to better support women in achieving recommended weight gain targets in pregnancy. PMID:27916921

  12. Development and validation of a self-administered questionnaire to estimate the distance and mode of children's travel to school in urban India.

    PubMed

    Tetali, Shailaja; Edwards, Phil; Murthy, G V S; Roberts, I

    2015-10-28

    Although some 300 million Indian children travel to school every day, little is known about how they get there. This information is important for transport planners and public health authorities. This paper presents the development of a self-administered questionnaire and examines its reliability and validity in estimating distance and mode of travel to school in a low resource urban setting. We developed a questionnaire on children's travel to school. We assessed test re-test reliability by repeating the questionnaire one week later (n = 61). The questionnaire was improved and re-tested (n = 68). We examined the convergent validity of distance estimates by comparing estimates based on the nearest landmark to children's homes with a 'gold standard' based on one-to-one interviews with children using detailed maps (n = 50). Most questions showed fair to almost perfect agreement. Questions on usual mode of travel (κ 0.73- 0.84) and road injury (κ 0.61- 0.72) were found to be more reliable than those on parental permissions (κ 0.18- 0.30), perception of safety (κ 0.00- 0.54), and physical activity (κ -0.01- 0.07). The distance estimated by the nearest landmark method was not significantly different than the in-depth method for walking , 52 m [95 % CI -32 m to 135 m], 10 % of the mean difference, and for walking and cycling combined, 65 m [95 % CI -30 m to 159 m], 11 % of the mean difference. For children who used motorized transport (excluding private school bus), the nearest landmark method under-estimated distance by an average of 325 metres [95 % CI -664 m to 1314 m], 15 % of the mean difference. A self-administered questionnaire was found to provide reliable information on the usual mode of travel to school, and road injury, in a small sample of children in Hyderabad, India. The 'nearest landmark' method can be applied in similar low-resource settings, for a reasonably accurate estimate of the distance from a child's home to school.

  13. Breast Shape Analysis With Curvature Estimates and Principal Component Analysis for Cosmetic and Reconstructive Breast Surgery.

    PubMed

    Catanuto, Giuseppe; Taher, Wafa; Rocco, Nicola; Catalano, Francesca; Allegra, Dario; Milotta, Filippo Luigi Maria; Stanco, Filippo; Gallo, Giovanni; Nava, Maurizio Bruno

    2018-03-20

    Breast shape is defined utilizing mainly qualitative assessment (full, flat, ptotic) or estimates, such as volume or distances between reference points, that cannot describe it reliably. We will quantitatively describe breast shape with two parameters derived from a statistical methodology denominated principal component analysis (PCA). We created a heterogeneous dataset of breast shapes acquired with a commercial infrared 3-dimensional scanner on which PCA was performed. We plotted on a Cartesian plane the two highest values of PCA for each breast (principal components 1 and 2). Testing of the methodology on a preoperative and postoperative surgical case and test-retest was performed by two operators. The first two principal components derived from PCA are able to characterize the shape of the breast included in the dataset. The test-retest demonstrated that different operators are able to obtain very similar values of PCA. The system is also able to identify major changes in the preoperative and postoperative stages of a two-stage reconstruction. Even minor changes were correctly detected by the system. This methodology can reliably describe the shape of a breast. An expert operator and a newly trained operator can reach similar results in a test/re-testing validation. Once developed and after further validation, this methodology could be employed as a good tool for outcome evaluation, auditing, and benchmarking.

  14. Increasing chlamydia test of re-infection rates using SMS reminders and incentives.

    PubMed

    Downing, Sandra Gaye; Cashman, Colette; McNamee, Heather; Penney, Debbie; Russell, Darren B; Hellard, Margaret E

    2013-02-01

    Clients diagnosed and treated for Chlamydia trachomatis are a recognised high-risk group for subsequent infection. An estimated 8% of clients treated for chlamydia at Cairns Sexual Health Service return for re-testing within the recommended 3-4-month period. There is no recall or reminder system in place. This study assesses the effectiveness of using short messaging service (SMS) reminders with and without incentive payments to increase re-testing rates. Eligible consenting clients were randomly allocated to one of three groups. Group 1 (controls) received the standard advice from the clinician to return for re-testing in 3-4 months. Group 2 received the standard advice and an SMS reminder at 10-12 weeks post-treatment. Group 3 received the standard advice and the SMS reminder, which also offered an incentive payment on clinic attendance. 32 participants were recruited to groups 1 and 2 and 30 participants to group 3. 62 SMS reminders were sent with 13 (21.0%) reported as undelivered. Re-testing rates were 6.3%, 28.1% and 26.7% for groups 1, 2 and 3, respectively. SMS reminders with or without an incentive payment increased re-testing rates in our clients who were diagnosed and treated for chlamydia. However, re-testing remained less than ideal, and the high rate of undelivered SMS reminders suggest that this intervention alone will not achieve desired re-testing rates and that a range of strategies will be required to increase re-testing in this population.

  15. 49 CFR 572.181 - General description.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) ANTHROPOMORPHIC TEST DEVICES 2re Side Impact Crash Test Dummy, 50th Percentile Adult Male § 572.181 General description. (a) The ES-2re Side Impact Crash Test... (PADI) of the ES-2re Side Impact Crash Test Dummy, February 2008, incorporated by reference, see § 572...

  16. Fatty acid ethyl esters (FAEEs) as markers for alcohol in meconium: method validation and implementation of a screening program for prenatal drug exposure.

    PubMed

    Hastedt, Martin; Krumbiegel, Franziska; Gapert, René; Tsokos, Michael; Hartwig, Sven

    2013-09-01

    Alcohol consumption during pregnancy is a widespread problem and can cause severe fetal damage. As the diagnosis of fetal alcohol syndrome is difficult, the implementation of a reliable marker for alcohol consumption during pregnancy into meconium drug screening programs would be invaluable. A previously published gas chromatography mass spectrometry method for the detection of fatty acid ethyl esters (FAEEs) as alcohol markers in meconium was optimized and newly validated for a sample size of 50 mg. This method was applied to 122 cases from a drug-using population. The meconium samples were also tested for common drugs of abuse. In 73 % of the cases, one or more drugs were found. Twenty percent of the samples tested positive for FAEEs at levels indicating significant alcohol exposure. Consequently, alcohol was found to be the third most frequently abused substance within the study group. This re-validated method provides an increase in testing sensitivity, is reliable and easily applicable as part of a drug screening program. It can be used as a non-invasive tool to detect high alcohol consumption in the last trimester of pregnancy. The introduction of FAEEs testing in meconium screening was found to be of particular use in a drug-using population.

  17. Validation of a pregnancy planning measure for Arabic-speaking women.

    PubMed

    Almaghaslah, Eman; Rochat, Roger; Farhat, Ghada

    2017-01-01

    The prevalence of unplanned pregnancy in Saudi Arabia has not been thoroughly investigated. To conduct a psychometric evaluation study of the Arabic version of the London Measure of Unplanned Pregnancy (LMUP). To evaluate the psychometric properties of the LMUP, we conducted a self-administered online survey among 796 ever-married Saudi women aged 20-49 years, and a re-test survey among 24 women. The psychometric properties evaluated included content validity measured by content validity index (CVI), structural validity assessed by exploratory factor analysis (EFA), substantive validity assessed by hypothesis testing, contextual stability for the test-retest assessed by weighted Kappa, and internal consistency assessed by Cronbach's alpha. The psychometric analysis of the Arabic version of LMUP exhibited valid and reliable properties. The CVIs for individual items and at the scale level were >0.7. EFA confirmed a unidimensional extraction of the scale item. Hypothesis testing confirmed expected associations. The tool was stable with weighted kappa = 0.78 and Cronbach's alpha = 0.88. In this study, the validity and reliability of the Arabic version of the LMUP were confirmed according to well-known psychometric criteria. This LMUP version can be used in research studies among Arabic-speaking women to measure unplanned pregnancy and investigate correlates and outcomes related to unplanned pregnancy.

  18. Validation of the Brief International Cognitive Assessment for Multiple Sclerosis in Japan.

    PubMed

    Niino, Masaaki; Fukazawa, Toshiyuki; Kira, Jun-Ichi; Okuno, Tatsusada; Mori, Masahiro; Sanjo, Nobuo; Ohashi, Takashi; Fukaura, Hikoaki; Fujimori, Juichi; Shimizu, Yuko; Mifune, Nobuhiro; Miyazaki, Yusei; Takahashi, Eri; Kikuchi, Seiji; Langdon, Dawn; Hb Benedict, Ralph; Matsui, Makoto

    2017-01-01

    The Brief International Cognitive Assessment for MS (BICAMS) is a practical battery for measuring cognitive function in multiple sclerosis (MS). We aimed to validate a Japanese version of the BICAMS in patients with MS and healthy controls. The Symbol Digit Modalities Test (SDMT), the California Verbal Learning Test-Second Edition (CVLT2) and the Brief Visuospatial Memory Test Revised (BVMTR) were administered to 156 patients with MS and 126 healthy controls (HCs). The BICAMS was re-administered in a subset of 27 MS patients and 30 HCs. The mean (±SD) raw scores in the MS and HC groups were as follows: SDMT: MS 47.9 ± 14.0, HC 61.0 ± 9.5; CVLT2: MS 48.6 ± 12.6, HC 55.7 ± 10.5; BVMTR: MS 23.5 ± 8.4, HC 28.3 ± 5.4, respectively, and significant differences were found between the two groups on all tests ( p  < 0.0001). Cohen's d values were 1.07, 0.60, and 0.67 in SDMT, CVLT2, and BVMTR, respectively. The test-retest reliability coefficients for each test were as follows: SDMT: r  = 0.93; CVLT2: r  = 0.82; and BVMTR: r  = 0.77 ( p  < 0.0001). This study provides results that support the reliability and validity of the BICAMS in Japan.

  19. The dissociation of video head impulse test (vHIT) and bithermal caloric test results provide topological localization of vestibular system impairment in patients with "definite" Ménière's disease.

    PubMed

    McCaslin, Devin L; Rivas, Alejandro; Jacobson, Gary P; Bennett, Marc L

    2015-03-01

    We report 3 patients with Ménière's disease and describe how the combination of audiometry, video head impulse testing, and caloric results may prove helpful in the diagnosis of Ménière's disease. Three patients with "definite" Ménière's disease were evaluated in a tertiary care medical center. Each patient underwent videonystagmography, horizontal canal video head impulse testing, and audiometry. All 3 patients demonstrated moderate, flat, sensorineural hearing losses; significant caloric asymmetries; and bilaterally normal video head impulse testing. This pattern of findings suggests differential preservation of high-frequency function (video head impulse testing) with impairment of low-frequency function (unilaterally abnormal caloric test results) in these patients. Ipsilesional abnormal caloric testing in the presence of normal video head impulse testing is a pattern of findings observed in a cohort of patients who have "definite" Ménière's disease.

  20. Intraoperative Physical Examination for Diagnosis of Interosseous Ligament Rupture-Cadaveric Study.

    PubMed

    Kachooei, Amir Reza; Rivlin, Michael; Wu, Fei; Faghfouri, Aram; Eberlin, Kyle R; Ring, David

    2015-09-01

    To study the intraobserver and interobserver reliability of the diagnosis of interosseous ligament (IOL) rupture in a cadaver model. On 12 fresh frozen cadavers, radial heads were cut using an identical incision and osteotomy. After randomization, the soft tissues of the limbs were divided into 4 groups: both IOL and triangular fibrocartilage (TFCC) intact; IOL disruption but TFCC intact; both IOL and TFCC divided; and IOL intact but TFCC divided. All incisions had identical suturing. After standard instruction and demonstration of radius pull-push and radius lateral pull tests, 10 physician evaluators with different levels of experience examined the cadaver limbs in a standardized way (elbow at 90° with the forearm held in both supination and pronation) and were asked to classify them into one of the 4 groups. Next, the same examiners were asked to re-examine the limbs after randomly changing the order of examination. The interobserver reliability of agreement for the diagnosis of IOL injury (groups 2 and 3) was fair in both rounds of examination and the intraobserver reliability was moderate. The intra- and interobserver reliabilities of agreement for the 4 groups of injuries among the examiners were fair in both rounds of examination. The sensitivity, specificity, accuracy, positive, and negative predictive values were all around 70%. The likelihood of a positive test corresponding with the presence of IOL rupture (positive likelihood ratio) was 2.2. The likelihood of a negative test correctly diagnosing an intact IOL was 0.40. In cadavers, intraoperative tests had fair reliability and 70% accuracy for the diagnosis of IOL rupture using the push-pull and lateral pull maneuvers. The level of experience did not have any effect on the correct diagnosis of intact versus disrupted IOL. Although not common, some failure of surgeries for traumatic elbow fracture-dislocations is because of failure in timely diagnosis of IOL disruption. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  1. The validation of a computer-adaptive test (CAT) for assessing health-related quality of life in children and adolescents in a clinical sample: study design, methods and first results of the Kids-CAT study.

    PubMed

    Barthel, D; Otto, C; Nolte, S; Meyrose, A-K; Fischer, F; Devine, J; Walter, O; Mierke, A; Fischer, K I; Thyen, U; Klein, M; Ankermann, T; Rose, M; Ravens-Sieberer, U

    2017-05-01

    Recently, we developed a computer-adaptive test (CAT) for assessing health-related quality of life (HRQoL) in children and adolescents: the Kids-CAT. It measures five generic HRQoL dimensions. The aims of this article were (1) to present the study design and (2) to investigate its psychometric properties in a clinical setting. The Kids-CAT study is a longitudinal prospective study with eight measurements over one year at two University Medical Centers in Germany. For validating the Kids-CAT, 270 consecutive 7- to 17-year-old patients with asthma (n = 52), diabetes (n = 182) or juvenile arthritis (n = 36) answered well-established HRQoL instruments (Pediatric Quality of Life Inventory™ (PedsQL), KIDSCREEN-27) and scales measuring related constructs (e.g., social support, self-efficacy). Measurement precision, test-retest reliability, convergent and discriminant validity were investigated. The mean standard error of measurement ranged between .38 and .49 for the five dimensions, which equals a reliability between .86 and .76, respectively. The Kids-CAT measured most reliably in the lower HRQoL range. Convergent validity was supported by moderate to high correlations of the Kids-CAT dimensions with corresponding PedsQL dimensions ranging between .52 and .72. A lower correlation was found between the social dimensions of both instruments. Discriminant validity was confirmed by lower correlations with non-corresponding subscales of the PedsQL. The Kids-CAT measures pediatric HRQoL reliably, particularly in lower areas of HRQoL. Its test-retest reliability should be re-investigated in future studies. The validity of the instrument was demonstrated. Overall, results suggest that the Kids-CAT is a promising candidate for detecting psychosocial needs in chronically ill children.

  2. Factors associated with a second deferral among donors eligible for re-entry after a false-positive screening test for syphilis, HCV, HBV and HIV.

    PubMed

    Grégoire, Y; Germain, M; Delage, G

    2018-05-01

    Since 25 May 2010, all donors at our blood centre who tested false-positive for HIV, HBV, HCV or syphilis are eligible for re-entry after further testing. Donors who have a second false-positive screening test, either during qualification for or after re-entry, are deferred for life. This study reports on factors associated with the occurrence of such deferrals. Rates of second false-positive results were compared by year of deferral, transmissible disease marker, gender, age, donor status (new or repeat) and testing platform (same or different) both at qualification for re-entry and afterwards. Chi-square tests were used to compare proportions. Cox regression was used for multivariate analyses. Participation rates in the re-entry programme were 42·1%: 25·6% failed to qualify for re-entry [different platform: 2·7%; same platform: 42·9% (P < 0·0001)]. After re-entry, rates of deferral for second false-positive results were 8·4% after 3 years [different platform: 1·8%; same platform: 21·4% (P < 0·0001)]. Deferral rates were higher for HIV and HCV than for HBV at qualification when tested on the same platform. The risk, when analysed by multivariate analyses, of a second deferral for a false-positive result, both at qualification and 3 years after re-entry, was lower for donors deferred on a different platform; this risk was higher for HIV, HCV and syphilis than for HBV and for new donors if tested on the same platform. Re-entry is more often successful when donors are tested on a testing platform different from the one on which they obtained their first false-positive result. © 2018 International Society of Blood Transfusion.

  3. Remote Recession Sensing of Ablative Heat Shield Materials

    NASA Technical Reports Server (NTRS)

    Winter, Michael W.; Stackpoole, Margaret; Nawaz, Anuscheh; Gonzales, Gregory Lewis; Ho, Thanh

    2014-01-01

    Material recession and charring are two major processes determining the performance of ablative heat shield materials. Even in ground testing, the characterization of these two mechanisms relies on measurements of material thickness before and after testing, thus providing only information integrated over the test time. For recession measurements, optical methods such as imaging the sample surface during testing are under investigation but require high alignment and instrument effort, therefore being not established as a standard measurement method. For char depth measurements, the most common method so far consists in investigation of sectioned samples after testing or in the case of Stardust where core extractions were performed to determine char information. In flight, no reliable recession measurements are available, except total recession after recovering the heat shield on ground. Developments of mechanical recession sensors have been started but require substantial on board instrumentation adding mass and complexity. In this work, preliminary experiments to evaluate the feasibility of remote sensing of material recession and possibly char depth through optically observing the emission signatures of seeding materials in the post shock plasma is investigated. It is shown that this method can provide time resolved recession measurements without the necessity of accurate alignment procedures of the optical set-up and without any instrumentation on board of a spacecraft. Furthermore, recession data can be obtained without recovering flight hardware which would be a huge benefit for inexpensive heat shield material testing on board of small re-entry probes, e.g. on new micro-satellite re-entry probes as a possible future application of Cubesats or RBR

  4. Validating Neuro-QoL short forms and targeted scales with people who have multiple sclerosis.

    PubMed

    Miller, Deborah M; Bethoux, Francois; Victorson, David; Nowinski, Cindy J; Buono, Sarah; Lai, Jin-Shei; Wortman, Katy; Burns, James L; Moy, Claudia; Cella, David

    2016-05-01

    Multiple sclerosis (MS) is a chronic, progressive, and disabling disease of the central nervous system with dramatic variations in the combination and severity of symptoms it can produce. The lack of reliable disease-specific health-related quality of life (HRQL) measures for use in clinical trials prompted the development of the Neurology Quality of Life (Neuro-QOL) instrument, which includes 13 scales that assess physical, emotional, cognitive, and social domains, for use in a variety of neurological illnesses. The objective of this research paper is to conduct an initial assessment of the reliability and validation of the Neuro-QOL short forms (SFs) in MS. We assessed reliability, concurrent validity, known groups validity, and responsiveness between cross-sectional and longitudinal data in 161 recruited MS patients. Internal consistency was high for all measures (α = 0.81-0.95) and ICCs were within the acceptable range (0.76-0.91); concurrent and known groups validity were highest with the Global HRQL question. Longitudinal assessment was limited by the lack of disease progression in the group. The Neuro-QOL SFs demonstrate good internal consistency, test-re-test reliability, and concurrent and known groups validity in this MS population, supporting the validity of Neuro-QOL in adults with MS. © The Author(s), 2015.

  5. Reliability and validity of the Dutch pediatric Voice Handicap Index.

    PubMed

    Veder, Laura; Pullens, Bas; Timmerman, Marieke; Hoeve, Hans; Joosten, Koen; Hakkesteegt, Marieke

    2017-05-01

    The pediatric voice handicap index (pVHI) has been developed to provide a better insight into the parents' perception of their child's voice related quality of life. The purpose of the present study was to validate the Dutch pVHI by evaluating its internal consistency and reliability. Furthermore, we determined the optimal cut-off point for a normal pVHI score. All items of the English pVHI were translated into Dutch. Parents of children in our dysphonic and control group were asked to fill out the questionnaire. For the test re-test analysis we used a different study group who filled out the pVHI twice as part of a large follow up study. Internal consistency was analyzed through Cronbach's α coefficient. The test-retest reliability was assessed by determining Pearson's correlation coefficient. Mann-Whitney test was used to compare the scores of the questionnaire of the control group with the dysphonic group. By calculating receiver operating characteristic (ROC) curves, sensitivity and specificity we were able to set a cut-off point. We obtained data from 122 asymptomatic children and from 79 dysphonic children. The scores of the questionnaire significantly differed between both groups. The internal consistency showed an overall Cronbach α coefficient of 0.96 and an excellent test-retest reliability of the total pVHI questionnaire with a Pearson's correlation coefficient of 0.90. A cut-off point for the total pVHI questionnaire was set at 7 points with a specificity of 85% and sensitivity of 100%. A cut-off point for the VAS score was set at 13 with a specificity of 93% and sensitivity of 97%. The Dutch pVHI is a valid and reliable tool for the assessment of children with voice problems. By setting a cut-off point for the score of the total pVHI questionnaire of 7 points and the VAS score of 13, the pVHI might be used as a screening tool to assess dysphonic complaints and the pVHI might be a useful and complementary tool to identify children with dysphonia. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Effect of Training on the Reliability of Satiety Evaluation and Use of Trained Panellists to Determine the Satiety Effect of Dietary Fibre: A Randomised Controlled Trial

    PubMed Central

    Solah, Vicky A.; Meng, Xingqiong; Wood, Simon; Gahler, Roland J.; Kerr, Deborah A.; James, Anthony P.; Pal, Sebely; Fenton, Haelee K.; Johnson, Stuart K.

    2015-01-01

    Background The assessment of satiety effects on foods is commonly performed by untrained volunteers marking their perceived hunger or fullness on line scales, marked with pre-set descriptors. The lack of reproducibility of satiety measurement using this approach however results in the tool being unable to distinguish between foods that have small, but possibly important, differences in their satiety effects. An alternate approach is used in sensory evaluation; panellists can be trained in the correct use of the assessment line-scale and brought to consensus on the meanings of descriptors used for food quality attributes to improve the panel reliability. The effect of training on the reliability of a satiety panel has not previously been reported. Method In a randomised controlled parallel intervention, the effect of training in the correct use of a satiety labelled magnitude scale (LMS) was assessed versus no-training. The test-retest precision and reliability of two hour postprandial satiety evaluation after consumption of a standard breakfast was compared. The trained panel then compared the satiety effect of two breakfast meals containing either a viscous or a non-viscous dietary fibre in a crossover trial. Results A subgroup of the 23 panellists (n = 5) improved their test re-test precision after training. Panel satiety area under the curve, “after the training” intervention was significantly different to “before training” (p < 0.001). Reliability of the panel determined by intraclass correlation (ICC) of test and retest showed improved strength of the correlation from 0.70 pre-intervention to 0.95 post intervention. The trained “satiety expert panel” determined that a standard breakfast with 5g of viscous fibre gave significantly higher satiety than with 5g non-viscous fibre (area under curve (AUC) of 478.2, 334.4 respectively) (p ≤ 0.002). Conclusion Training reduced between panellist variability. The improved strength of test-retest ICC as a result of the training intervention suggests that training satiety panellists can improve the discriminating power of satiety evaluation. PMID:25978321

  7. Effect of training on the reliability of satiety evaluation and use of trained panellists to determine the satiety effect of dietary fibre: a randomised controlled trial.

    PubMed

    Solah, Vicky A; Meng, Xingqiong; Wood, Simon; Gahler, Roland J; Kerr, Deborah A; James, Anthony P; Pal, Sebely; Fenton, Haelee K; Johnson, Stuart K

    2015-01-01

    The assessment of satiety effects on foods is commonly performed by untrained volunteers marking their perceived hunger or fullness on line scales, marked with pre-set descriptors. The lack of reproducibility of satiety measurement using this approach however results in the tool being unable to distinguish between foods that have small, but possibly important, differences in their satiety effects. An alternate approach is used in sensory evaluation; panellists can be trained in the correct use of the assessment line-scale and brought to consensus on the meanings of descriptors used for food quality attributes to improve the panel reliability. The effect of training on the reliability of a satiety panel has not previously been reported. In a randomised controlled parallel intervention, the effect of training in the correct use of a satiety labelled magnitude scale (LMS) was assessed versus no-training. The test-retest precision and reliability of two hour postprandial satiety evaluation after consumption of a standard breakfast was compared. The trained panel then compared the satiety effect of two breakfast meals containing either a viscous or a non-viscous dietary fibre in a crossover trial. A subgroup of the 23 panellists (n = 5) improved their test re-test precision after training. Panel satiety area under the curve, "after the training" intervention was significantly different to "before training" (p < 0.001). Reliability of the panel determined by intraclass correlation (ICC) of test and retest showed improved strength of the correlation from 0.70 pre-intervention to 0.95 post intervention. The trained "satiety expert panel" determined that a standard breakfast with 5g of viscous fibre gave significantly higher satiety than with 5g non-viscous fibre (area under curve (AUC) of 478.2, 334.4 respectively) (p ≤ 0.002). Training reduced between panellist variability. The improved strength of test-retest ICC as a result of the training intervention suggests that training satiety panellists can improve the discriminating power of satiety evaluation.

  8. An enhanced cluster analysis program with bootstrap significance testing for ecological community analysis

    USGS Publications Warehouse

    McKenna, J.E.

    2003-01-01

    The biosphere is filled with complex living patterns and important questions about biodiversity and community and ecosystem ecology are concerned with structure and function of multispecies systems that are responsible for those patterns. Cluster analysis identifies discrete groups within multivariate data and is an effective method of coping with these complexities, but often suffers from subjective identification of groups. The bootstrap testing method greatly improves objective significance determination for cluster analysis. The BOOTCLUS program makes cluster analysis that reliably identifies real patterns within a data set more accessible and easier to use than previously available programs. A variety of analysis options and rapid re-analysis provide a means to quickly evaluate several aspects of a data set. Interpretation is influenced by sampling design and a priori designation of samples into replicate groups, and ultimately relies on the researcher's knowledge of the organisms and their environment. However, the BOOTCLUS program provides reliable, objectively determined groupings of multivariate data.

  9. Product manufacturing, quality, and reliability initiatives to maintain a competitive advantage and meet customer expectations in the semiconductor industry

    NASA Astrophysics Data System (ADS)

    Capps, Gregory

    Semiconductor products are manufactured and consumed across the world. The semiconductor industry is constantly striving to manufacture products with greater performance, improved efficiency, less energy consumption, smaller feature sizes, thinner gate oxides, and faster speeds. Customers have pushed towards zero defects and require a more reliable, higher quality product than ever before. Manufacturers are required to improve yields, reduce operating costs, and increase revenue to maintain a competitive advantage. Opportunities exist for integrated circuit (IC) customers and manufacturers to work together and independently to reduce costs, eliminate waste, reduce defects, reduce warranty returns, and improve quality. This project focuses on electrical over-stress (EOS) and re-test okay (RTOK), two top failure return mechanisms, which both make great defect reduction opportunities in customer-manufacturer relationship. Proactive continuous improvement initiatives and methodologies are addressed with emphasis on product life cycle, manufacturing processes, test, statistical process control (SPC), industry best practices, customer education, and customer-manufacturer interaction.

  10. Chinese version of the Perceived Stress Scale-10: A psychometric study in Chinese university students.

    PubMed

    Lu, Wei; Bian, Qian; Wang, Wenzheng; Wu, Xiaoling; Wang, Zhen; Zhao, Min

    2017-01-01

    Chinese university students often suffer from acute stress, which can affect their mental health. We measured and evaluated perceived stress in this population using the Simplified Chinese version of the 10-item Perceived Stress Scale (SCPSS-10). The SCPSS-10, Patient Health Questionnaire (PHQ), and Generalized Anxiety Disorder 7-item scale (GAD-7) were conducted in 1096 university students. Two weeks later, 129 participants were re-tested using the SCPSS-10. Exploratory factor analysis yielded two factors with Eigen values of 4.76 and 1.48, accounting for 62.41% of the variance. Confirmatory factor analysis demonstrated good fit of this two-factor model. The internal consistency reliability, as measured by Cronbach's α, was 0.85. The test-retest reliability coefficient was 0.7. The SCPSS-10 exhibited high correlation with the PHQ-9 and GAD-7, indicating an acceptable concurrent validity. The SCPSS-10 exhibited satisfactory psychometric properties in Chinese university students.

  11. Inter-rater and test-retest reliability of quality assessments by novice student raters using the Jadad and Newcastle-Ottawa Scales.

    PubMed

    Oremus, Mark; Oremus, Carolina; Hall, Geoffrey B C; McKinnon, Margaret C

    2012-01-01

    Quality assessment of included studies is an important component of systematic reviews. The authors investigated inter-rater and test-retest reliability for quality assessments conducted by inexperienced student raters. Student raters received a training session on quality assessment using the Jadad Scale for randomised controlled trials and the Newcastle-Ottawa Scale (NOS) for observational studies. Raters were randomly assigned into five pairs and they each independently rated the quality of 13-20 articles. These articles were drawn from a pool of 78 papers examining cognitive impairment following electroconvulsive therapy to treat major depressive disorder. The articles were randomly distributed to the raters. Two months later, each rater re-assessed the quality of half of their assigned articles. McMaster Integrative Neuroscience Discovery and Study Program. 10 students taking McMaster Integrative Neuroscience Discovery and Study Program courses. The authors measured inter-rater reliability using κ and the intraclass correlation coefficient type 2,1 or ICC(2,1). The authors measured test-retest reliability using ICC(2,1). Inter-rater reliability varied by scale question. For the six-item Jadad Scale, question-specific κs ranged from 0.13 (95% CI -0.11 to 0.37) to 0.56 (95% CI 0.29 to 0.83). The ranges were -0.14 (95% CI -0.28 to 0.00) to 0.39 (95% CI -0.02 to 0.81) for the NOS cohort and -0.20 (95% CI -0.49 to 0.09) to 1.00 (95% CI 1.00 to 1.00) for the NOS case-control. For overall scores on the six-item Jadad Scale, ICC(2,1)s for inter-rater and test-retest reliability (accounting for systematic differences between raters) were 0.32 (95% CI 0.08 to 0.52) and 0.55 (95% CI 0.41 to 0.67), respectively. Corresponding ICC(2,1)s for the NOS cohort were -0.19 (95% CI -0.67 to 0.35) and 0.62 (95% CI 0.25 to 0.83), and for the NOS case-control, the ICC(2,1)s were 0.46 (95% CI -0.13 to 0.92) and 0.83 (95% CI 0.48 to 0.95). Inter-rater reliability was generally poor to fair and test-retest reliability was fair to excellent. A pilot rating phase following rater training may be one way to improve agreement.

  12. Comparative testing of reliability and audit utility of ordinal objective calculus complexity scores. Can we make an informed choice yet?

    PubMed

    Jaipuria, Jiten; Suryavanshi, Manav; Sen, Tridib K

    2016-12-01

    To assess the reliability of the Guy's Stone Score, the Seoul National University Renal Stone Complexity (S-ReSC) score and the S.T.O.N.E. scores in percutaneous nephrolithotomy (PCNL), and assess their utility in discriminating outcomes [stone free rate (SFR), complications, need for multiple PCNL sessions, and auxiliary procedures] valid across parameters of experience of surgeon, independence from surgical approach, and variations in institution-specific instrumentation. A prospectively maintained database of two tertiary institutions was analysed (606 cases). Institutes differed in instrumentation, while the overall surgical team comprised: two trainees (experience <100 cases), two junior consultants (experience 100-200 cases), and two senior surgeons (experience >1000 cases). Scores were assigned and re-assigned after 4 months by one trainee and an expert surgeon. Inter-rater and test-retest agreement were analysed by Cohen's κ and intraclass correlation coefficient. Multivariate logistic regression models were created adjusting outcomes for the institution, comorbidity, Amplatz size, access tract location, the number of punctures, the experience level of the surgeon, and individual scoring system, and receiver operating curves were analysed for comparison. Despite some areas of inconsistencies, individually all scores had excellent inter-rater and test-retest concordance. On multivariable analyses, while the experience of the surgeon and surgical approach characteristics (such as access tract location, Amplatz size, and number of punctures) remained independently associated with different outcomes in varying combinations, calculus complexity scores were found consistently to be independently associated with all outcomes. The S-ReSC score had a superior association with SFR, the need for multiple PCNL sessions, and auxiliary procedures. Individually all scoring systems performed well. On cross comparison, the S-ReSC score consistently emerged to be more superiorly associated with all outcomes, signifying the importance of the distributional complexity of the calculus (which also indirectly amalgamates the influence of stone number, size, and anatomical location) in discriminating outcomes. Our study proves the utility of scoring systems in prognosticating multiple outcomes and also clarifies important aspects of their practical application including future roles such as benchmarking, audit, training, and objective assessment of surgical technique modifications. © 2016 The Authors BJU International © 2016 BJU International Published by John Wiley & Sons Ltd.

  13. Short message service reminder intervention doubles sexually transmitted infection/HIV re-testing rates among men who have sex with men.

    PubMed

    Bourne, C; Knight, V; Guy, R; Wand, H; Lu, H; McNulty, A

    2011-04-01

    To evaluate the impact of a short message service (SMS) reminder system on HIV/sexually transmitted infection (STI) re-testing rates among men who have sex with men (MSM). The SMS reminder programme started in late 2008 at a large Australian sexual health clinic. SMS reminders were recommended 3-6 monthly for MSM considered high-risk based on self-reported sexual behaviour. The evaluation compared HIV negative MSM who had a HIV/STI test between 1 January and 31 August 2010 and received a SMS reminder (SMS group) with those tested in the same time period (comparison group) and pre-SMS period (pre-SMS group, 1 January 2008 and 31 August 2008) who did not receive the SMS. HIV/STI re-testing rates were measured within 9 months for each group. Baseline characteristics were compared between study groups and multivariate logistic regression used to assess the association between SMS and re-testing and control for any imbalances in the study groups. There were 714 HIV negative MSM in the SMS group, 1084 in the comparison group and 1753 in the pre-SMS group. In the SMS group, 64% were re-tested within 9 months compared to 30% in the comparison group (p<0.001) and 31% in the pre-SMS group (p<0.001). After adjusting for baseline differences, re-testing was 4.4 times more likely (95% CI 3.5 to 5.5) in the SMS group than the comparison group and 3.1 times more likely (95% CI 2.5 to 3.8) than the pre-SMS group. SMS reminders increased HIV/STI re-testing among HIV negative MSM. SMS offers a cheap, efficient system to increase HIV/STI re-testing in a busy clinical setting.

  14. 76 FR 55082 - Re-Accreditation and Re-Approval Intertek Testing Services as a Commercial Gauger and Laboratory

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-06

    ... DEPARTMENT OF HOMELAND SECURITY Bureau of Customs and Border Protection Re-Accreditation and Re... Border Protection, Department of Homeland Security. ACTION: Notice of re-approval of Intertek Testing..., Texas 78406, has been re-approved to gauge petroleum and petroleum products, organic chemicals and...

  15. RHrFPGA Radiation-Hardened Re-programmable Field-Programmable Gate Array

    NASA Technical Reports Server (NTRS)

    Sanders, A. B.; LaBel, K. A.; McCabe, J. F.; Gardner, G. A.; Lintz, J.; Ross, C.; Golke, K.; Burns, B.; Carts, M. A.; Kim, H. S.

    2004-01-01

    Viewgraphs on the development of the Radiation-Hardened Re-programmable Field-Programmable Gate Array (RHrFPGA) are presented. The topics include: 1) Radiation Test Suite; 2) Testing Interface; 3) Test Configuration; 4) Facilities; 5) Test Programs; 6) Test Procedure; and 7) Test Results. A summary of heavy ion and proton testing is also included.

  16. Alpha-fetoprotein and its value for predicting pregnancy outcomes – a re-evaluation

    PubMed Central

    Darouich, Ayham Alhaj; Liehr, Thomas; Weise, Anja; Schlembach, Dietmar; Schleußner, Ekkehart; Kiehntopf, Michael; Schreyer, Isolde

    2015-01-01

    Introduction Alpha-fetoprotein (AFP) concentrations can be determined framing others from invasively acquired amnion fluid (AF-AFP). While the biological role of AFP remains unclear it is well known that AFP-levels can be altered in connection with specific clinical and/or genetic alterations of the fetus. Materials and Method here a retrospective study based on 3,119 singleton and 56 twin pregnancies is presented. The standard levels of amnion fluid derived alpha-fetoprotein level (AF-AFP) between 12th and 36th weeks of gestation were determined. Additionally, acetylcholinesterase (AChE) test results for 63 cases, ultrasonography results for 32 cases and abnormal karyotypic findings for 100 cases were available for selected cases. Results and Discussion according to the present data the AF-AFP test is reliable and provides expected test results in terms of population studies. However, individual AF-AFP test results can be subject to high individual variations. In this study AF-AFP multiple of medians (MoM) over 1.7 were indicative for neuronal tube defects and/or omphalocele in only 6.3% of the cases, while such AF-AFP values were hints on severe sonographic signs in 62% of the cases. Also, altered AF-AFP concentrations were present in 82% of cytogenetically abnormal cases. Overall, even though predicative value of the AF-AFP-test is matter of discussion it continues to be widely applied in invasive prenatal diagnostics. This study indicates that it only can be applied reliably in combination with other tests like banding cytogenetics, ultrasonography and all embedded in well-established genetic counseling. PMID:27358693

  17. 49 CFR 572.181 - General description.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) ANTHROPOMORPHIC TEST DEVICES ES-2re Side Impact Crash Test Dummy, 50th Percentile Adult Male § 572.181 General description. (a) The ES-2re Side Impact Crash... (PADI) of the ES-2re Side Impact Crash Test Dummy, February 2008, incorporated by reference, see § 572...

  18. 49 CFR 572.181 - General description.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) ANTHROPOMORPHIC TEST DEVICES ES-2re Side Impact Crash Test Dummy, 50th Percentile Adult Male § 572.181 General description. (a) The ES-2re Side Impact Crash... (PADI) of the ES-2re Side Impact Crash Test Dummy, February 2008, incorporated by reference, see § 572...

  19. Smart Sensor Node Development, Testing and Implementation for Rocket Propulsion Systems

    NASA Technical Reports Server (NTRS)

    Mengers, Timothy R.; Shipley, John; Merrill, Richard; Eggett, Leon; Johnson, Mont; Morris, Jonathan; Figueroa, Fernando; Schmalzel, John; Turowski, Mark P.

    2007-01-01

    Successful design and implementation of an Integrated System Health Management (ISHM) approach for rocket propulsion systems requires the capability improve the reliability of complex systems by detecting and diagnosing problems. One of the critical elements in the ISHM is an intelligent sensor node for data acquisition that meets specific requirements for rocket motor testing including accuracy, sample rate and size/weight. Traditional data acquisition systems are calibrated in a controlled environment and guaranteed to perform bounded by their tested conditions. In a real world ISHM system, the data acquisition and signal conditioning needs to function in an uncontrolled environment. Development and testing of this sensor node focuses on a design with the ability to self check in order to extend calibration times, report internal faults and drifts and notify the overall system when the data acquisition is not performing as it should. All of this will be designed within a system that is flexible, requiring little re-design to be deployed on a wide variety of systems. Progress in this design and initial testing of prototype units will be reported.

  20. Impact Testing of the H1224A Shipping/Storage Container

    DTIC Science & Technology

    1994-05-01

    may not provide significant ener- gy absorption for the re - entry vehicle midsection but can provide some confinement of potentially damaged...Horizontal Low-Velocity impact test LHV Longitudinal High-Velocity impact test HHV Horizontal High-Velocity impact test RV Re - entry Vehicle midsection mass...Also, integration of these pulses showed that only a much shorter dura- tion pulse was necessary to slow the re - entry vehicle midsection velocity

  1. Cross-cultural Adaptation, Reliability, and Validity of the Yoruba Version of the Roland-Morris Disability Questionnaire.

    PubMed

    Mbada, Chidozie Emmanuel; Idowu, Opeyemi Ayodiipo; Ogunjimi, Olawale Richard; Ayanniyi, Olusola; Orimolade, Elkanah Ayodele; Oladiran, Ajibola Babatunde; Johnson, Olubusola Esther; Akinsulore, Adesanmi; Oni, Temitope Olawale

    2017-04-01

    A translation, cross-cultural adaptation, and psychometric analysis. The aim of this study was to translate, cross-culturally adapt, and validate the Yoruba version of the RMDQ. The Roland-Morris Disability Questionnaire (RMDQ) is a valid outcome tool for low back pain (LBP) in clinical and research settings. There seems to be no valid and reliable version of the RMDQ in the Nigerian languages. Following the Guillemin criteria, the English version of the RMDQ was forward and back translated. Two Yoruba translated versions of the RMDQ were assessed for clarity, common language usage, and conceptual equivalence. Consequently, a harmonized Yoruba version was produced and was pilot-tested among 20 patients with nonspecific long-term LBP (NSLBP) for cognitive debriefing. The final version of the Yoruba RMDQ was tested for its construct validity and re-retest reliability among 120 and 87 patients with NSLBP, respectively. Pearson product moment correlation coefficient (r) of 0.82 was obtained for reliability of the Yoruba version of the RMDQ. The test-retest reliability of the Yoruba RMDQ yielded Cronbach alpha 0.932, while the intraclass correlation (ICC) ranged between 0.896 and 0.956. The analysis of the global scores of both the English and Yoruba versions of the RMDQ yielded ICC value of between 0.995 (95% confidence interval 0.996-0.997), with the item-by-item Kappa agreement ranging between 0.824 and 1.000. The external validity of RMDQ using Quadruple Visual Analogue Scale was r = -0.596 (P = 0.001). The Yoruba version of the RMDQ had no floor/ceiling effects, as no patient achieved either of the maximum or the minimum possible scores. The Yoruba version of the RMDQ has excellent reliability and validity and may be an appropriate outcome tool for clinical and research purposes among Yoruba-speaking patients with LBP. 3.

  2. Construct validity and reliability of the Finnish version of the Knee Injury and Osteoarthritis Outcome Score.

    PubMed

    Multanen, Juhani; Honkanen, Mikko; Häkkinen, Arja; Kiviranta, Ilkka

    2018-05-22

    The Knee Injury and Osteoarthritis Outcome Score (KOOS) is a commonly used knee assessment and outcome tool in both clinical work and research. However, it has not been formally translated and validated in Finnish. The purpose of this study was to translate and culturally adapt the KOOS questionnaire into Finnish and to determine its validity and reliability among Finnish middle-aged patients with knee injuries. KOOS was translated and culturally adapted from English into Finnish. Subsequently, 59 patients with knee injuries completed the Finnish version of KOOS, Western Ontario and McMaster Osteoarthritis Index (WOMAC), Short-Form 36 Health Survey (SF-36) and Numeric Pain Rating Scale (Pain-NRS). The same KOOS questionnaire was re-administered 2 weeks later. Psychometric assessment of the Finnish KOOS was performed by testing its construct validity and reliability by using internal consistency, test-retest reliability and measurement error. The floor and ceiling effects were also examined. The cross-cultural adaptation revealed only minor cultural differences and was well received by the patients. For construct validity, high to moderate Spearman's Correlation Coefficients were found between the KOOS subscales and the WOMAC, SF-36, and Pain-NRS subscales. The Cronbach's alpha was from 0.79 to 0.96 for all subscales indicating acceptable internal consistency. The test-retest reliability was good to excellent, with Intraclass Correlation Coefficients ranging from 0.73 to 0.86 for all KOOS subscales. The minimal detectable change ranged from 17 to 34 on an individual level and from 2 to 4 on a group level. No floor or ceiling effects were observed. This study yielded an appropriately translated and culturally adapted Finnish version of KOOS which demonstrated good validity and reliability. Our data indicate that the Finnish version of KOOS is suitable for assessment of the knee status of Finnish patients with different knee complaints. Further studies are needed to evaluate the predictive ability of KOOS in the Finnish population.

  3. The development of aerobic and skill assessment in soccer.

    PubMed

    O'Reilly, John; Wong, Stephen H S

    2012-12-01

    Methods of assessing soccer players' performance have developed significantly in recent times. The fitness profiles and skill levels of a prospective elite soccer player is a valuable resource for coaches in the process of identifying talent. Traditional means to measure aerobic fitness have centred on the 'aerobic capacity' or '&OV0312;O(2max)' test (also known as the maximal oxygen consumption test) but, over time, this has been shown not to be a sensitive measure for specific aspects of soccer in a match situation. Therefore, numerous soccer-specific simulations have been designed to re-create exercise patterns similar to those experienced during a match. Some of these studies have yet to be validated, while others have been shown to result in a similar physiological load to that encountered during regular match play. Further developments have led to specifically designed intermittent sprint tests, which are used as a sensitive tool to accurately measure the fluctuations in players' ability both between and within soccer seasons. Testing procedures have also been developed that incorporate elements of both skill and physical ability. Soccer-specific field tests have been designed, incorporating skill and dynamic movements, and this opens up the possibility of teams testing the aerobic capacity of their elite players using soccer-specific movements. Valid studies assessing soccer-specific skills in an ecologically sound environment have been quite rare until recently. Some test protocols have been deemed largely irrelevant to soccer match play, while others have had limited impact on scientific literature. More recently, skill tests have been developed and shown to be valid and reliable methods of assessing soccer skill performance. Many new skill tests continue to be developed, and some have been shown to be highly reliable, but further study of these relatively novel concepts is required before a more solid recommendation can be made. Overall, while significant work has been completed to date, there is still a need for further focused investigations, which can more closely assess the physiological demands of an elite soccer player, with a particular emphasis on sport-specific exercises during the execution of soccer skills. In this regard, more reliable and specific performance tests can be designed to more efficiently assess soccer players in the future.

  4. Reliability of provocative tests of motion sickness susceptibility

    NASA Technical Reports Server (NTRS)

    Calkins, D. S.; Reschke, M. F.; Kennedy, R. S.; Dunlop, W. P.

    1987-01-01

    Test-retest reliability values were derived from motion sickness susceptibility scores obtained from two successive exposures to each of three tests: (1) Coriolis sickness sensitivity test; (2) staircase velocity movement test; and (3) parabolic flight static chair test. The reliability of the three tests ranged from 0.70 to 0.88. Normalizing values from predictors with skewed distributions improved the reliability.

  5. Spaceflight Ground Support Equipment Reliability & System Safety Data

    NASA Technical Reports Server (NTRS)

    Fernandez, Rene; Riddlebaugh, Jeffrey; Brinkman, John; Wilkinson, Myron

    2012-01-01

    Presented were Reliability Analysis, consisting primarily of Failure Modes and Effects Analysis (FMEA), and System Safety Analysis, consisting of Preliminary Hazards Analysis (PHA), performed to ensure that the CoNNeCT (Communications, Navigation, and Networking re- Configurable Testbed) Flight System was safely and reliably operated during its Assembly, Integration and Test (AI&T) phase. A tailored approach to the NASA Ground Support Equipment (GSE) standard, NASA-STD-5005C, involving the application of the appropriate Requirements, S&MA discipline expertise, and a Configuration Management system (to retain a record of the analysis and documentation) were presented. Presented were System Block Diagrams of selected GSE and the corresponding FMEA, as well as the PHAs. Also discussed are the specific examples of the FMEAs and PHAs being used during the AI&T phase to drive modifications to the GSE (via "redlining" of test procedures, and the placement of warning stickers to protect the flight hardware) before being interfaced to the Flight System. These modifications were necessary because failure modes and hazards were identified during the analysis that had not been properly mitigated. Strict Configuration Management was applied to changes (whether due to upgrades or expired calibrations) in the GSE by revisiting the FMEAs and PHAs to reflect the latest System Block Diagrams and Bill Of Material. The CoNNeCT flight system has been successfully assembled, integrated, tested, and shipped to the launch site without incident. This demonstrates that the steps taken to safeguard the flight system when it was interfaced to the various GSE were successful.

  6. Inflatable re-entry shield ready for test in space

    NASA Astrophysics Data System (ADS)

    2000-02-01

    The Russian spacecraft Mars'96 for instance, which was launched in November 1996 but failed to reach its nominal orbit, carried two modules designed to land on that planet's surface. For the last part of the mission, an Inflatable Re-Entry and Descent Technology (IRDT) had been deployed. The main components of this system were an aerobraking and thermally protective shell, a densely packed inflating material and a pressurisation system. This technology is now considered applicable to other re-entry scenarios such as payload recovery from the International Space Station, planetary landers for science missions and atmospheric research. A demonstration mission on 9/10 February 2000 will evaluate the performance of this new technology before it is offered to potential users. A Russian Soyuz/Fregat launcher, lifting off from the Kazakh steppe near Baikonur, will provide a low-cost flight opportunity for the test vehicle, which is equipped with the inflatable heat shield and a sensor package developed by DaimlerChrysler Aerospace (DASA). After four orbits around the Earth, the test vehicle will be powered by the launcher's upper stage to re-enter the atmosphere for a landing the next day about 1800 km north-west of the launch site. During the mission, a number of technical parameters such as pressure, temperature and deceleration will be monitored and the inflation of the re-entry/descent structure observed. "From this novel technology, we are expecting a major breakthrough, to make re-entry of small payloads more and more reliable, simpler and less costly than traditional systems", explains Dieter Kassing, ESA's IRDT project manager. One of the main instruments on board the test vehicle is a sensor device developed by the University of Stuttgart for the determination of oxygen partial pressure in low Earth orbit and during re-entry. The scientific/technical investigations will be led by Dr. Ulrich Schoettle (Stuttgart University). Lionel Marraffa (ESA) will lead the evaluation of the IRDT's aerothermodynamic behaviour. DASA was responsible for integration of the sensor package and is ESA's co-investigator for evaluation of the application aspects of this new technology. In addition to the sensor package, the mission will accommodate a collection of special stones to study the physical and chemical modifications in sedimentary rocks, i.e. simulated meteorites, during atmospheric infall. Co-investors of this experiment are Dr. André Brack (CNRS, Orleans) and Dr. Gero Kurat (Vienna University). This experiment is being co-sponsored by ESA. The Russian/European Starsem launch company and NPO Lavochkin, the Russian company that developed the original IRDT technology, will be responsible for launch, orbit control, re-entry and recovery of the sensor package under contract with the International Science & Technology Centre (Moscow). ESA, the European Commission and DASA are co-funding this contract, contributing $600K each.

  7. Psychometric Properties of Translation of the Child Perception Questionnaire (CPQ11-14) in Telugu Speaking Indian Children.

    PubMed

    Kumar, Santhosh; Kroon, Jeroen; Lalloo, Ratilal; Johnson, Newell W

    2016-01-01

    Oral health related quality of life research among children in India is still nascent and no measures have been validated to date. Although CPQ11-14 has been previously used in studies from the Indian sub-continent, the instrument has never been tested for cross-cultural adaptability. This study aimed to assess the validity and reliability of CPQ11-14 in Telugu speaking Indian school children. Primary school children of Medak district, Telangana State, India, were recruited by a multi-stage probability sampling method. The translated questionnaire was initially pilot tested on a small subset of children (n = 40). Children with informed consent from parents (N = 1342) were then provided with questionnaires containing the Telugu translation of CPQ11-14, followed by a clinical examination conducted by a single examiner, using Basic WHO survey methods for dental caries, malocclusion, and Dean's Fluorosis index. Children (n = 161) in randomly chosen schools were re-administered the same questionnaire after a two week interval to test reliability of CPQ11-14 on repeated administrations. Internal consistency and test-retest reliability as determined by Cronbach's alpha and Intra-class correlation coefficient for overall CPQ11-14 scale were 0.925 and 0.923, respectively. CPQ11-14 discriminated between the categories of fluorosis and malocclusion while its discriminant validity with respect to dental caries was limited. CPQ11-14 also demonstrated good construct validity with both overall CPQ11-14 and its subscales having significant positive correlation with global ratings of oral health and overall wellbeing, even after adjusting for confounding variables. CPQ11-14 had a correlation of 0.405 with self-evaluated oral health and 0.407 with self-evaluated impact of oral health on overall wellbeing. In conclusion, Telugu translation of CPQ11-14 demonstrated good internal consistency and excellent reliability on repeated administrations after two weeks. It also exhibited good discriminant and construct validity.

  8. Uterine Fibroid Symptom - Quality of Life questionnaire translation and validation into Brazilian Portuguese.

    PubMed

    Silva, Rita Oliveira da; Gomes, Mariano Tamura Vieira; Castro, Rodrigo de Aquino; Bonduki, Cláudio Emílio; Girão, Manoel João Batista Castello

    2016-10-01

    Purpose  To translate into Portuguese, culturally adapt and validate the Uterine Fibroid Symptom - Quality of Life (UFS-QoL) questionnaire for Brazilian women with uterine leiomyoma. Methods  Initially, the UFS-QoL questionnaire was translated into Brazilian Portuguese in accordance with international standards, with subsequent cultural, structural, conceptual and semantic adaptations, so that patients were able to properly answer the questionnaire. Fifty patients with uterine leiomyoma and 19 patients without the disease, confirmed by abdominal pelvic examination and/or transvaginal ultrasound, were selected at the outpatient clinics of the Department of Gynecology of the Universidade Federal de São Paulo (Unifesp). The UFS-QoL questionnaire was administered to all women twice on the same day, with two different interviewers, with an interval of 15 minutes between interviews. After 15 days, the questionnaire was re-administered by the first interviewer. Reliability (internal consistency and test-retest), construct and discriminative validity were tested to ratify the questionnaire. Results  The reliability of the instrument was assessed by Cronbach's α coefficient with an overall result of 0.97, indicating high reliability. The survey results showed a high correlation ( p  = 0.94; p  ≤ 0.001). Conclusion  The UFS-QoL questionnaire was successfully adapted to the Brazilian Portuguese language and Brazilian culture, showing reliability and validity. Thieme Publicações Ltda Rio de Janeiro, Brazil.

  9. Requirements for long-life operation of inert gas hollow cathodes: Preliminary report

    NASA Technical Reports Server (NTRS)

    Verhey, Timothy R.; Macrae, Gregory S.

    1990-01-01

    An experimental investigation was initiated to establish conditioning procedures for reliable hollow cathode operation via the characterization of critical parameters in a representative cathode test facility. From vacuum pumpdown rates, it was found that approximately 1.5 hours were required to achieve pressure levels within 5 percent of the lowest attainable pressure for this facility, depending on the purge conditions. The facility atmosphere was determined by a residual gas analyzer to be composed of primarily air and water vapor. The effects of vacuum pumping and inert gas purging were evaluated. A maximum effective leakage rate of 2.0 x 10(exp -3)sccm was observed and its probable causes were examined. An extended test of a 0.64 cm diameter Mo-Re hollow cathode was successfully completed. This test ran for 504 hours at an emission current of 23.0 amperes and a xenon flow rate of 6.1 sccm. Discharge voltage rose continuously from 15 to 21 volts over the course of the test. The temperature of the cathode body during the test was relatively stable at 1160 C. Post-test examination revealed ion-bombardment texturing of the orifice plate to be the only detectable sign of wear on the hollow cathode.

  10. Speech and Language Disorders in Kenyan Children: Adapting Tools For Regions With Few Assessment Resources

    PubMed Central

    Carter, Julie Anne; Murira, Grace; Gona, Joseph; Tumaini, Judy; Lees, Janet; Neville, Brian George; Newton, Charles Richard

    2013-01-01

    This study sought to adapt a battery of Western speech and language assessment tools to a rural Kenyan setting. The tool was developed for children whose first language was KiGiryama, a Bantu language. A total of 539 Kenyan children (males=271, females=268, ethnicity=100% Kigiryama. Data were collected from 303 children admitted to hospital with severe malaria and 206 age-matched children recruited from the village communities. The language assessments were based upon the Content, Form and Use (C/F/U) model. The assessment was based upon the adapted versions of the Peabody Picture Vocabulary Test, Test for the Reception of Grammar, Renfrew Action Picture Test, Pragmatics Profile of Everyday Communication Skills in Children, Test of Word Finding and language specific tests of lexical semantics, higher level language. Preliminary measures of construct validity suggested that the theoretical assumptions behind the construction of the assessments were appropriate and re-test and inter-rater reliability scores were acceptable. These findings illustrate the potential to adapt Western speech and language assessments in other languages and settings, particularly those in which there is a paucity of standardised tools. PMID:24294109

  11. Reliability of sternal instability scale (SIS) for transverse sternotomy in lung transplantation (LTX).

    PubMed

    Fuller, Louise M; El-Ansary, Doa; Button, Brenda; Bondarenko, Janet; Marasco, Silvana; Snell, Greg; Holland, Anne E

    2018-01-25

    A surgical incision for bilateral sequential lung transplantation (BSLTX) is the "clam shell" (CSI) approach via bilateral anterior thoracotomies and a transverse sternotomy to allow for sequential replacement of the lungs. This can be associated with significant post-operative pain, bony overriding or sternal instability. The sternal instability scale (SIS) is a non-invasive manual assessment tool that can be used to detect early bony non-union or instability following CSI; however, its reliability is unknown. This prospective blinded reliability study aimed to assess intra-rater and inter-rater reliability of the SIS following lung transplantation. Participants post BSLTX aged older than 18 years underwent sternal assessment utilizing the SIS. Two assessors examined the sternum using a standardized protocol at two separate time points with a test-re-test time of 48 hours. The outcome measure was SIS tool using four categories from 0 (clinically stable) to 3 (separated sternum with overriding). In total, 20 participants (75% female) with a mean age of 48 years (SD 17) and mean pain score of 3 out of 10 were included, 60% having well healed wounds and 25% reporting symptoms of sternal clicking. The most painful self-reported painful activity was coughing. The SIS demonstrated excellent reliability with a kappa = 0.91 by different assessors on the same day, and kappa = 0.83 for assessments by the same assessor on different days. The SIS is a reliable manual assessment tool for evaluation of sternal instability after CSI following BSLTX and may facilitate the timely detection and management of sternal instability.

  12. XPS investigations of tribolayers formed on TiN and (Ti,Re)N coatings

    NASA Astrophysics Data System (ADS)

    Oktay, Serkan; Kahraman, Zafer; Urgen, Mustafa; Kazmanli, Kursat

    2015-02-01

    TiN and (Ti,Re)N coatings were deposited on high-speed-steel substrates by a hybrid coating system composed of cathodic arc PVD and magnetron sputtering techniques. In order to keep rhenium content low (8 ± 1.9 at.%) in the coating, magnetron sputtering technique was utilized to evaporate rhenium. The (Ti,Re)N coating consisted of TiN and ReNx (x > 1.33) phases. The hardness of TiN and (Ti,Re)N were 31 GPa and 29 GPa (± 2 GPa), respectively. Tribological behaviors of the samples were tested against Al2O3 balls at 21 °C (RT) and 150 °C (HT) by reciprocating wear technique. The tribolayers were analyzed by XPS technique. Friction coefficients of TiN were 0.56, 0.35 for 21 °C and 150 °C tests, respectively. Rhenium addition to TiN drastically dropped the friction coefficients to 0.22 and 0.17 for RT and HT samples. Rhenium addition also improved the wear resistance of the coating at both test temperatures. For TiN, main oxide component of the tribolayers was Ti2O3 for RT tests and TiO2 for HT tests. The oxide layer formed on (Ti,Re)N were the mixture of TiO2, Tisbnd Osbnd N, ReO2 and Re2O7 for both test temperatures. Re2O7 provided very low friction coefficient to (Ti,Re)N. The findings are consistent with the crystal chemistry approach.

  13. The reliability of WorkWell Systems Functional Capacity Evaluation: a systematic review

    PubMed Central

    2014-01-01

    Background Functional capacity evaluation (FCE) determines a person’s ability to perform work-related tasks and is a major component of the rehabilitation process. The WorkWell Systems (WWS) FCE (formerly known as Isernhagen Work Systems FCE) is currently the most commonly used FCE tool in German rehabilitation centres. Our systematic review investigated the inter-rater, intra-rater and test-retest reliability of the WWS FCE. Methods We performed a systematic literature search of studies on the reliability of the WWS FCE and extracted item-specific measures of inter-rater, intra-rater and test-retest reliability from the identified studies. Intraclass correlation coefficients ≥ 0.75, percentages of agreement ≥ 80%, and kappa coefficients ≥ 0.60 were categorised as acceptable, otherwise they were considered non-acceptable. The extracted values were summarised for the five performance categories of the WWS FCE, and the results were classified as either consistent or inconsistent. Results From 11 identified studies, 150 item-specific reliability measures were extracted. 89% of the extracted inter-rater reliability measures, all of the intra-rater reliability measures and 96% of the test-retest reliability measures of the weight handling and strength tests had an acceptable level of reliability, compared to only 67% of the test-retest reliability measures of the posture/mobility tests and 56% of the test-retest reliability measures of the locomotion tests. Both of the extracted test-retest reliability measures of the balance test were acceptable. Conclusions Weight handling and strength tests were found to have consistently acceptable reliability. Further research is needed to explore the reliability of the other tests as inconsistent findings or a lack of data prevented definitive conclusions. PMID:24674029

  14. Association between elder abuse and poor sleep: A cross-sectional study among rural older Malaysians.

    PubMed

    Yunus, Raudah Mohd; Wazid, Syeda Wasfeea; Hairi, Noran N; Choo, Wan Yuen; Hairi, Farizah M; Sooryanarayana, Rajini; Ahmad, Sharifah N; Razak, Inayah A; Peramalah, Devi; Aziz, Suriyati A; Mohamad, Zaiton L; Mohamad, Rosmala; Ali, Zainudin M; Bulgiba, Awang

    2017-01-01

    To examine the association between elder abuse and poor sleep using a Malay validated version of Pittsburgh Sleep Quality Index (PSQI). This study was divided into two phases. Phase I tested the construct validity and reliability of the Malay version of PSQI. Phase II was a population-based, cross-sectional study with a multi-stage cluster sampling method. Home-based interviews were conducted by trained personnel using a structured questionnaire, to determine exposure and outcome. Kuala Pilah, a district in Negeri Sembilan which is one of the fourteen states in Malaysia. 1648 community-dwelling older Malaysians. The Malay version of PSQI had significant test re-test reliability with intra-class correlation coefficients of 0.62. Confirmatory factor analyses revealed that one factor PSQI scale with three components (subjective sleep quality, sleep latency, and sleep disturbances) was most suitable. Cronbach's Alpha was 0.60 and composite reliability was 0.63. PSQI scores were highest among neglect (4.11), followed by physical (4.10), psychological (3.96) and financial abuse (3.60). There was a dose-response relationship between clustering of abuse and PSQI scores; 3.41, 3.50 and 3.84 for "no abuse", "1 type of abuse" and "2 types or more". Generalized linear models revealed six variables as significant determinants of sleep quality-abuse, co-morbidities, self-rated health, income, social support and gait speed. Among abuse subtypes, only neglect was significantly associated with poor sleep. The Malay PSQI was valid and reliable. Abuse was significantly associated with poor sleep. As sleep is essential for health and is a good predictor for mortality among older adults, management of abuse victims should entail sleep assessment. Interventions or treatment modalities which focus on improving sleep quality among abuse victims should be designed.

  15. Test-retest reliability of a single-channel, wireless EEG system.

    PubMed

    Rogers, Jeffrey M; Johnstone, Stuart J; Aminov, Anna; Donnelly, James; Wilson, Peter H

    2016-08-01

    Recording systems to acquire electroencephalogram (EEG) data are traditionally lab-based. However, there are shortcomings to this method, and the ease of use and portability of emerging wireless EEG technologies offer a promising alternative. A previous validity study demonstrated data derived from a single-channel, wireless system (NeuroSky ThinkGear, San Jose, California) is comparable to EEG recorded from conventional lab-based equipment. The current study evaluated the reliability of this portable system using test-retest and reliable change analyses. Relative power (RP) of delta, theta, alpha, and beta frequency bands was derived from EEG data obtained from a single electrode over FP1 in 19 healthy youth (10-17years old), 21 healthy adults (18-28years old), and 19 healthy older adults (55-79years old), during eyes-open, eyes-closed, auditory oddball, and visual n-back conditions. Intra-class correlations (ICCs) and Coefficients of Repeatability (CRs) were calculated from RP data re-collected one-day, one-week, and one-month later. Participants' levels of mood and attention were consistent across sessions. Eyes-closed resting EEG measurements using the portable device were reproducible (ICCs 0.76-0.85) at short and longer retest intervals in all three participant age groups. While still of at least fair reliability (ICCs 0.57-0.85), EEG obtained during eyes-open paradigms was less stable, and any change observed over time during these testing conditions can be interpreted utilizing the CR values provided. Combined with existing validity data, these findings encourage application of the portable EEG system for the study of brain function. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Cross-cultural Adaptation of a Questionnaire on Self-perceived Level of Skills, Abilities and Competencies of Family Physicians in Albania.

    PubMed

    Alla, Arben; Czabanowska, Katarzyna; Kijowska, Violetta; Roshi, Enver; Burazeri, Genc

    2012-01-01

    Our aim was to validate an international instrument measuring self-perceived competency level of family physicians in Albania. A representative sample of 57 family physicians operating in primary health care services was interviewed twice in March-April 2012 in Tirana (26 men and 31 women; median age: 46 years, inter-quartile range: 38-56 years). A structured questionnaire was administered [and subsequently re-administered after two weeks (test-retest)] to all family physicians aiming to self-assess physicians' level of abilities, skills and competencies regarding different domains of quality of health care. The questionnaire included 37 items organized into 6 subscales/domains. Answers for each item of the tool ranged from 1 ("novice" physicians) to 5 ("expert" physicians). An overall summary score (range: 37-185) and a subscale summary score for each domain were calculated for the test and retest procedures. Cronbach's alpha was used to assess the internal consistency for both the test and the retest procedures, whereas Spearman's rho was employed to assess the stability over time (test-retest reliability) of the instrument. Cronbach's alpha was 0.87 for the test and 0.86 for the retest procedure. Overall, Spearman's rho was 0.84 (P<0.001). The overall summary score for the 37 items of the instrument was 96.3±10.0 for the test and 97.3±10.1 for the retest. All the subscale summary scores were very similar for the test and the retest procedure. This study provides evidence on cross-cultural adaptation of an international instrument taping self-perceived level of competencies of family physicians in Albania. The questionnaire displayed a satisfactory internal consistency for both test and retest procedures in this sample of family physicians in Albania. Furthermore, the high test-retest reliability (stability over time) of the instrument suggests a good potential for wide scale application to nationally representative samples of family physicians in Albanian populations.

  17. Comparing reliabilities of strip and conventional patch testing.

    PubMed

    Dickel, Heinrich; Geier, Johannes; Kreft, Burkhard; Pfützner, Wolfgang; Kuss, Oliver

    2017-06-01

    The standardized protocol for performing the strip patch test has proven to be valid, but evidence on its reliability is still missing. To estimate the parallel-test reliability of the strip patch test as compared with the conventional patch test. In this multicentre, prospective, randomized, investigator-blinded reliability study, 132 subjects were enrolled. Simultaneous duplicate strip and conventional patch tests were performed with the Finn Chambers ® on Scanpor ® tape test system and the patch test preparations nickel sulfate 5% pet., potassium dichromate 0.5% pet., and lanolin alcohol 30% pet. Reliability was estimated by the use of Cohen's kappa coefficient. Parallel-test reliability values of the three standard patch test preparations turned out to be acceptable, with slight advantages for the strip patch test. The differences in reliability were 9% (95%CI: -8% to 26%) for nickel sulfate and 23% (95%CI: -16% to 63%) for potassium dichromate, both favouring the strip patch test. The standardized strip patch test method for the detection of allergic contact sensitization in patients with suspected allergic contact dermatitis is reliable. Its application in routine clinical practice can be recommended, especially if the conventional patch test result is presumably false negative. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Reliability and validity of the revised Gibson Test of Cognitive Skills, a computer-based test battery for assessing cognition across the lifespan.

    PubMed

    Moore, Amy Lawson; Miller, Terissa M

    2018-01-01

    The purpose of the current study is to evaluate the validity and reliability of the revised Gibson Test of Cognitive Skills, a computer-based battery of tests measuring short-term memory, long-term memory, processing speed, logic and reasoning, visual processing, as well as auditory processing and word attack skills. This study included 2,737 participants aged 5-85 years. A series of studies was conducted to examine the validity and reliability using the test performance of the entire norming group and several subgroups. The evaluation of the technical properties of the test battery included content validation by subject matter experts, item analysis and coefficient alpha, test-retest reliability, split-half reliability, and analysis of concurrent validity with the Woodcock Johnson III Tests of Cognitive Abilities and Tests of Achievement. Results indicated strong sources of evidence of validity and reliability for the test, including internal consistency reliability coefficients ranging from 0.87 to 0.98, test-retest reliability coefficients ranging from 0.69 to 0.91, split-half reliability coefficients ranging from 0.87 to 0.91, and concurrent validity coefficients ranging from 0.53 to 0.93. The Gibson Test of Cognitive Skills-2 is a reliable and valid tool for assessing cognition in the general population across the lifespan.

  19. Global bias reliability in dogs (Canis familiaris).

    PubMed

    Mongillo, Paolo; Pitteri, Elisa; Sambugaro, Pamela; Carnier, Paolo; Marinelli, Lieta

    2017-03-01

    Dogs enrolled in a previous study were assessed two years later for reliability of their local/global preference in a discrimination test with the same hierarchical stimuli used in the previous study (Experiment 1) and with a novel stimulus (Experiment 2). In Experiment 1, dogs easily re-learned to discriminate the positive stimulus; their individual global/local choices were stable compared to the previous study; and an overall clear global bias was found. In Experiment 2, dogs were slower in acquiring the initial discrimination task; the overall global bias disappeared; and, individually, dogs tended to make inverse choices compared to the original study. Spontaneous attention toward the test stimulus resembling the global features of the probe stimulus was the main factor affecting the likeliness of a global choice of our dogs, regardless of the type of experiment. However, attention to task-irrelevant elements increased at the expense of attention to the stimuli in the test phase of Experiment 2. Overall, the results suggest that the stability of global bias in dogs depends on the characteristics of the assessment contingencies, likely including the learning requirements of the tasks. Our results also clearly indicate that attention processes have a prominent role on dogs' global bias, in agreement with previous findings in humans and other species.

  20. Thermal-Structural Analysis of PICA Tiles for Solar Tower Test

    NASA Technical Reports Server (NTRS)

    Agrawal, Parul; Empey, Daniel M.; Squire, Thomas H.

    2009-01-01

    Thermal protection materials used in spacecraft heatshields are subjected to severe thermal and mechanical loading environments during re-entry into earth atmosphere. In order to investigate the reliability of PICA tiles in the presence of high thermal gradients as well as mechanical loads, the authors designed and conducted solar-tower tests. This paper presents the design and analysis work for this tests series. Coupled non-linear thermal-mechanical finite element analyses was conducted to estimate in-depth temperature distribution and stress contours for various cases. The first set of analyses performed on isolated PICA tile showed that stresses generated during the tests were below the PICA allowable limit and should not lead to any catastrophic failure during the test. The tests results were consistent with analytical predictions. The temperature distribution and magnitude of the measured strains were also consistent with predicted values. The second test series is designed to test the arrayed PICA tiles with various gap-filler materials. A nonlinear contact method is used to model the complex geometry with various tiles. The analyses for these coupons predict the stress contours in PICA and inside gap fillers. Suitable mechanical loads for this architecture will be predicted, which can be applied during the test to exceed the allowable limits and demonstrate failure modes. Thermocouple and strain-gauge data obtained from the solar tower tests will be used for subsequent analyses and validation of FEM models.

  1. Validation of the Chinese Version of the Quality of Nursing Work Life Scale

    PubMed Central

    Fu, Xia; Xu, Jiajia; Song, Li; Li, Hua; Wang, Jing; Wu, Xiaohua; Hu, Yani; Wei, Lijun; Gao, Lingling; Wang, Qiyi; Lin, Zhanyi; Huang, Huigen

    2015-01-01

    Quality of Nursing Work Life (QNWL) serves as a predictor of a nurse’s intent to leave and hospital nurse turnover. However, QNWL measurement tools that have been validated for use in China are lacking. The present study evaluated the construct validity of the QNWL scale in China. A cross-sectional study was conducted conveniently from June 2012 to January 2013 at five hospitals in Guangzhou, which employ 1938 nurses. The participants were asked to complete the QNWL scale and the World Health Organization Quality of Life abbreviated version (WHOQOL-BREF). A total of 1922 nurses provided the final data used for analyses. Sixty-five nurses from the first investigated division were re-measured two weeks later to assess the test-retest reliability of the scale. The internal consistency reliability of the QNWL scale was assessed using Cronbach’s α. Test-retest reliability was assessed using the intra-class correlation coefficient (ICC). Criterion-relation validity was assessed using the correlation of the total scores of the QNWL and the WHOQOL-BREF. Construct validity was assessed with the following indices: χ2 statistics and degrees of freedom; relative mean square error of approximation (RMSEA); the Akaike information criterion (AIC); the consistent Akaike information criterion (CAIC); the goodness-of-fit index (GFI); the adjusted goodness of fit index; and the comparative fit index (CFI). The findings demonstrated high internal consistency (Cronbach’s α = 0.912) and test-retest reliability (interclass correlation coefficient = 0.74) for the QNWL scale. The chi-square test (χ2 = 13879.60, df [degree of freedom] = 813 P = 0.0001) was significant. The RMSEA value was 0.091, and AIC = 1806.00, CAIC = 7730.69, CFI = 0.93, and GFI = 0.74. The correlation coefficient between the QNWL total scores and the WHOQOL-BREF total scores was 0.605 (p<0.01). The QNWL scale was reliable and valid in Chinese-speaking nurses and could be used as a clinical and research instrument for measuring work-related factors among nurses in China. PMID:25950838

  2. Toward reliable characterization of functional homogeneity in the human brain: Preprocessing, scan duration, imaging resolution and computational space

    PubMed Central

    Zuo, Xi-Nian; Xu, Ting; Jiang, Lili; Yang, Zhi; Cao, Xiao-Yan; He, Yong; Zang, Yu-Feng; Castellanos, F. Xavier; Milham, Michael P.

    2013-01-01

    While researchers have extensively characterized functional connectivity between brain regions, the characterization of functional homogeneity within a region of the brain connectome is in early stages of development. Several functional homogeneity measures were proposed previously, among which regional homogeneity (ReHo) was most widely used as a measure to characterize functional homogeneity of resting state fMRI (R-fMRI) signals within a small region (Zang et al., 2004). Despite a burgeoning literature on ReHo in the field of neuroimaging brain disorders, its test–retest (TRT) reliability remains unestablished. Using two sets of public R-fMRI TRT data, we systematically evaluated the ReHo’s TRT reliability and further investigated the various factors influencing its reliability and found: 1) nuisance (head motion, white matter, and cerebrospinal fluid) correction of R-fMRI time series can significantly improve the TRT reliability of ReHo while additional removal of global brain signal reduces its reliability, 2) spatial smoothing of R-fMRI time series artificially enhances ReHo intensity and influences its reliability, 3) surface-based R-fMRI computation largely improves the TRT reliability of ReHo, 4) a scan duration of 5 min can achieve reliable estimates of ReHo, and 5) fast sampling rates of R-fMRI dramatically increase the reliability of ReHo. Inspired by these findings and seeking a highly reliable approach to exploratory analysis of the human functional connectome, we established an R-fMRI pipeline to conduct ReHo computations in both 3-dimensions (volume) and 2-dimensions (surface). PMID:23085497

  3. Reliability of two social cognition tests: The combined stories test and the social knowledge test.

    PubMed

    Thibaudeau, Élisabeth; Cellard, Caroline; Legendre, Maxime; Villeneuve, Karèle; Achim, Amélie M

    2018-04-01

    Deficits in social cognition are common in psychiatric disorders. Validated social cognition measures with good psychometric properties are necessary to assess and target social cognitive deficits. Two recent social cognition tests, the Combined Stories Test (COST) and the Social Knowledge Test (SKT), respectively assess theory of mind and social knowledge. Previous studies have shown good psychometric properties for these tests, but the test-retest reliability has never been documented. The aim of this study was to evaluate the test-retest reliability and the inter-rater reliability of the COST and the SKT. The COST and the SKT were administered twice to a group of forty-two healthy adults, with a delay of approximately four weeks between the assessments. Excellent test-retest reliability was observed for the COST, and a good test-retest reliability was observed for the SKT. There was no evidence of practice effect. Furthermore, an excellent inter-rater reliability was observed for both tests. This study shows a good reliability of the COST and the SKT that adds to the good validity previously reported for these two tests. These good psychometrics properties thus support that the COST and the SKT are adequate measures for the assessment of social cognition. Copyright © 2018. Published by Elsevier B.V.

  4. Laser ignition of an experimental combustion chamber with a multi-injector configuration at low pressure conditions

    NASA Astrophysics Data System (ADS)

    Börner, Michael; Manfletti, Chiara; Kroupa, Gerhard; Oschwald, Michael

    2017-09-01

    In search of reliable and light-weight ignition systems for re-ignitable upper stage engines, a laser ignition system was adapted and tested on an experimental combustion chamber for propellant injection into low combustion chamber pressures at 50-80 mbar. The injector head pattern consisted of five coaxial injector elements. Both, laser-ablation-driven ignition and laser-plasma-driven ignition were tested for the propellant combination liquid oxygen and gaseous hydrogen. The 122 test runs demonstrated the reliability of the ignition system for different ignition configurations and negligible degradation due to testing. For the laser-plasma-driven scheme, minimum laser pulse energies needed for 100% ignition probability were found to decrease when increasing the distance of the ignition location from the injector faceplate with a minimum of 2.6 mJ. For laser-ablation-driven ignition, the minimum pulse energy was found to be independent of the ablation material tested and was about 1.7 mJ. The ignition process was characterized using both high-speed Schlieren and OH* emission diagnostics. Based on these findings and on the increased fiber-based pulse transport capabilities recently published, new ignition system configurations for space propulsion systems relying on fiber-based pulse delivery are formulated. If the laser ignition system delivers enough pulse energy, the laser-plasma-driven configuration represents the more versatile configuration. If the laser ignition pulse power is limited, the application of laser-ablation-driven ignition is an option to realize ignition, but implies restrictions concerning the location of ignition.

  5. Cross-cultural adaptation and validation of the Saudi Arabic version of the Knee Injury and Osteoarthritis Outcome Score (KOOS).

    PubMed

    Alfadhel, Saud A; Vennu, Vishal; Alnahdi, Ali H; Omar, Mohammed T; Alasmari, Saeed H; AlJafri, Zahra; Bindawas, Saad M

    2018-06-07

    The Knee Injury Osteoarthritis Outcome Score (KOOS) is a widely used joint-specific measure employed to evaluate pain, symptoms, activities of daily living, recreational activities, and quality of life in patients with knee osteoarthritis (OA). Although the original KOOS has been translated into many languages, a Saudi Arabic version is not available. This study aimed to culturally adapt and evaluate the psychometric properties of the Saudi Arabic version of the KOOS in patients with knee OA. The original KOOS was translated and adapted into Saudi Arabic version over six stages according to the guidelines suggested by Beaton and recommended by the American Association of Orthopedic Surgeons Outcome Committee. Patients diagnosed with knee OA (n = 136) were recruited to examine the psychometric properties, such as internal consistency that was tested using Cronbach's alpha, test-retest reliability that was analyzed using the intra-class correlation coefficient (ICC 2,1 ), and construct validity that examined by testing the correlations between the new version subscales, Form 36 Health Survey subscales, and the Visual Analog Scale, Spearman's correlation coefficient (r s ) was used to measure the correlations. A total of 122 (89.7%) of the 136 participants with knee OA completed the second re-test of new Saudi Arabic version. Excellent internal consistency (Cronbach's alpha = 0.87-0.92) was detected in the subscales of the adapted version, as well as excellent test-retest reliability (ICC 2,1  = 0.92-0.94). The pattern of correlation between the subscales of the Saudi Arabic version of the KOOS, SF-36 domains and the Visual Analog Scale for pain supported the construct validity of the adapted version. The Saudi Arabic version of the KOOS was well accepted and exhibited excellent reliability, internal consistency, and construct validity in Saudi patients with knee OA.

  6. Validity and reliability of a questionnaire to assess social skills in traumatic brain injury: A preliminary study.

    PubMed

    Francis, Heather M; Osborne-Crowley, Katherine; McDonald, Skye

    2017-01-01

    To describe the reliability and validity of a new measure, the Social Skills Questionnaire for Traumatic Brain Injury (SSQ-TBI). Fifty-one adults with severe TBI completed the SSQ-TBI questionnaire. Scores were compared to informant- and self-report on questionnaires addressing frontal lobe mediated behaviour, as well as performance on an objective measure of social cognition and neuropsychological tasks, in order to provide evidence of concurrent, divergent and predictive validity. Internal consistency was excellent at α = 0.90. Convergent validity was good, with informant ratings on the SSQ-TBI significantly correlated with Neuropsychiatric Inventory Disinhibition sub-scales (r = 0.50-63), the Current Behaviour Scale (r = 0.39-0.48) and Frontal Systems Behaviour Scale (r = 0.60-0.83). However, no relationship was seen with an objective measure of social skills or neuropsychological tasks of disinhibition. There was a significant relationship with real-world psychosocial outcomes on the Sydney Psychosocial Reintegration Scale-2 (r = -0.38--0.69) Conclusions: This study provides preliminary findings of good internal consistency and convergent and predictive validity of a social skills questionnaire adapted to be appropriate for individuals with TBI. Further assessment of psychometric properties such as test-re-test reliability and factor structure is warranted.

  7. An examination of gas compressor stability and rotating stall

    NASA Technical Reports Server (NTRS)

    Fozi, Aziz A.

    1987-01-01

    The principal sources of vibration related reliability problems in high pressure centrifugal gas compressors are the re-excitation of the first critical speed or Resonant Subsynchronous Vibration (RSSV), and the forced vibration due to rotating stall in the vaneless diffusers downstream of the impellers. An example of such field problems is given elsewhere. This paper describes the results of a test program at the author's company, initiated in 1983 and completed during 1985, which studied the RSSV threshold and the rotating stall phenomenon in a high pressure gas compressor.

  8. Ongoing Capabilities and Developments of Re-Entry Plasma Ground Tests at EADS-ASTRIUM

    NASA Technical Reports Server (NTRS)

    Jullien, Pierre

    2008-01-01

    During re-entry, spacecrafts are subjected to extreme thermal loads. On mars, they may go through dust storms. These external heat loads are leading the design of re-entry vehicles or are affecting it for spacecraft facing solid propellant jet stream. Sizing the Thermal Protection System require a good knowledge of such solicitations and means to model and reproduce them on earth. Through its work on European projects, ASTRIUM has developed the full range of competences to deal with such issues. For instance, we have designed and tested the heat-shield of the Huygens probe which landed on Titan. In particular, our plasma generators aim to reproduce a wide variety of re-entry conditions. Heat loads are generated by the huge speed of the probes. Such conditions cannot be fully reproduced. Ground tests focus on reproducing local aerothermal loads by using slower but hotter flows. Our inductive plasma torch enables to test little samples at low TRL. Amongst the arc-jets, one was design to test architecture design of ISS crew return system and others fit more severe re-entry such as sample returns or Venus re-entry. The last developments aimed in testing samples in seeded flows. First step was to design and test the seeding device. Special diagnostics characterizing the resulting flow enabled us to fit it to the requirements.

  9. A standard for test reliability in group research.

    PubMed

    Ellis, Jules L

    2013-03-01

    Many authors adhere to the rule that test reliabilities should be at least .70 or .80 in group research. This article introduces a new standard according to which reliabilities can be evaluated. This standard is based on the costs or time of the experiment and of administering the test. For example, if test administration costs are 7 % of the total experimental costs, the efficient value of the reliability is .93. If the actual reliability of a test is equal to this efficient reliability, the test size maximizes the statistical power of the experiment, given the costs. As a standard in experimental research, it is proposed that the reliability of the dependent variable be close to the efficient reliability. Adhering to this standard will enhance the statistical power and reduce the costs of experiments.

  10. Re-examination of the Present Stress State of the Atera Fault, Central Japan, Based on the Calibrated Crustal Stress Data of Hydraulic Fracturing Test by Measuring the Tensile Strength of Rocks

    NASA Astrophysics Data System (ADS)

    Yamashita, F.; Mizoguchi, K.; Fukuyama, E.; Omura, K.

    2008-12-01

    To infer the activity and physical state of intraplate faults in Japan, we re-examined the crustal stress with the hydraulic fracturing test by measuring the tensile strength of rocks. The tensile strength was measured by fracturing hollow cylindrical rock samples (inner and outer radius are 25.0-25.2 mm and 55.1-101.5 mm, respectively, length is 137.0-140.1 mm) which were obtained close to the in situ stress measurement locations by pressurizing the inner hole of the sample. Confining pressure is not applied to the samples in this test. To check the reliability and accuracy of this test, we conducted similar experiments with the standard rock sample (Inada granite) whose physical property is well known. Then, we measured the tensile strength of all available core samples including the Atera fault (at Ueno, Fukuoka, and Hatajiri), the Atotsugawa fault, and the Nojima fault (at Hirabayashi, Iwaya and Kabutoyama), in central Japan, which had been obtained by the National Research Institute for Earth Science and Disaster Prevention (NIED) by the stress measurement with the hydraulic fracturing method. The measured tensile strength data reveals that the in situ re- opening pressure, which is one of the parameters needed for the determination of the maximum in situ horizontal stress, was obviously biased. We re-estimated the re-opening pressure using the measured tensile strength and the in situ breakdown pressure, and re-calculated the in situ stress around the Atera fault. Although the past dislocation of the Atera fault has been considered to be left lateral from the geographical features around the fault, the re-estimated stress suggests that the present dislocation of the Atera fault is right lateral. And the shear stress decreases from the fault. The right lateral dislocation is also supported by the present-day horizontal crustal deformation observed by the triangular and GPS surveys by Geographical Survey Institute in Japan. Therefore, the dislocation direction of the Atera fault seems to change from left lateral to right lateral some time ago. The amount of accumulated right lateral dislocation estimated from the stress data with the dislocation model by Okada (1992) is 2.2-2.6 m. Because the current slip rate from the GPS survey is 2.1-2.3 mm/yr, the accumulation period of the dislocation becomes 960-1240 years if the slip rate is stable. This estimation suggests that during the last 1586 Tensho earthquake the Atera fault dislocated right laterally.

  11. Test-retest and interrater reliability of the functional lower extremity evaluation.

    PubMed

    Haitz, Karyn; Shultz, Rebecca; Hodgins, Melissa; Matheson, Gordon O

    2014-12-01

    Repeated-measures clinical measurement reliability study. To establish the reliability and face validity of the Functional Lower Extremity Evaluation (FLEE). The FLEE is a 45-minute battery of 8 standardized functional performance tests that measures 3 components of lower extremity function: control, power, and endurance. The reliability and normative values for the FLEE in healthy athletes are unknown. A face validity survey for the FLEE was sent to sports medicine personnel to evaluate the level of importance and frequency of clinical usage of each test included in the FLEE. The FLEE was then administered and rated for 40 uninjured athletes. To assess test-retest reliability, each athlete was tested twice, 1 week apart, by the same rater. To assess interrater reliability, 3 raters scored each athlete during 1 of the testing sessions. Intraclass correlation coefficients were used to assess the test-retest and interrater reliability of each of the FLEE tests. In the face validity survey, the FLEE tests were rated as highly important by 58% to 71% of respondents but frequently used by only 26% to 45% of respondents. Interrater reliability intraclass correlation coefficients ranged from 0.83 to 1.00, and test-retest reliability ranged from 0.71 to 0.95. The FLEE tests are considered clinically important for assessing lower extremity function by sports medicine personnel but are underused. The FLEE also is a reliable assessment tool. Future studies are required to determine if use of the FLEE to make return-to-play decisions may reduce reinjury rates.

  12. Differentiation of subsequent memory effects between retrieval practice and elaborative study.

    PubMed

    Liu, Yi; Rosburg, Timm; Gao, Chuanji; Weber, Christine; Guo, Chunyan

    2017-07-01

    Retrieval practice enhances memory retention more than re-studying. The underlying mechanisms of this retrieval practice effect have remained widely unclear. According to the elaborative retrieval hypothesis, activation of elaborative information occurs to a larger extent during testing than re-studying. In contrast, the episodic context account has suggested that recollecting prior episodic information (especially the temporal context) contributes to memory retention. To adjudicate the distinction between these two accounts, the present study used the classical retrieval practice effect paradigm to compare retrieval practice and elaborative study. In an initial behavioral experiment, retrieval practice produced greater retention than elaboration and re-studying in a one-week delayed test. In a subsequent event-related potential (ERP) experiment, retrieval practice resulted in reliably superior accuracy in the delayed test compared to elaborative study. In the ERPs, a frontally distributed subsequent memory effect (SME), starting at 300ms, occurred in the elaborative study condition, but not in the retrieval practice condition. A parietal SME emerged in the retrieval practice condition from 500 to 700ms, but was absent in the elaborative study condition. After 700ms, a late SME was present in the retrieval practice condition, but not in the elaborative study condition. Moreover, SMEs lasted longer in retrieval practice than in elaboration. The frontal SME in the elaborative study condition might be related to semantic processing or working memory-based elaboration, whereas the parietal and widespread SME in the retrieval practice condition might be associated with episodic recollection processes. These findings contradict the elaborative retrieval theory, and suggest that contextual recollection rather than activation of semantic information contributes to the retrieval practice effect, supporting the episodic context account. Copyright © 2017. Published by Elsevier B.V.

  13. Modeling Reliability Growth in Accelerated Stress Testing

    DTIC Science & Technology

    2013-12-01

    MODELING RELIABILITY GROWTH IN ACCELERATED STRESS TESTING DISSERTATION Jason K. Freels Major...Defense, or the United States Government. AFIT-ENS-DS-13-D-02 MODELING RELIABILITY GROWTH IN ACCELERATED STRESS TESTING ...DISTRIBUTION UNLIMITED AFIT-ENS-DS-13-D-02 MODELING RELIABILITY GROWTH IN ACCELERATED STRESS TESTING Jason K. Freels

  14. Reliability and Validity of a Two-Question Alcohol Screen in the Pediatric Emergency Department.

    PubMed

    Spirito, Anthony; Bromberg, Julie R; Casper, T Charles; Chun, Thomas H; Mello, Michael J; Dean, J Michael; Linakis, James G

    2016-12-01

    A multisite study was conducted to determine the psychometric properties of the National Institute of Alcohol Abuse and Alcoholism (NIAAA) 2-question alcohol screen within pediatric emergency departments (PEDs). Participants (N = 4838) included 12- to 17-year-old subjects treated in 1 of the 16 participating PEDs across the United States. A criterion assessment battery (including the NIAAA 2-question alcohol screen and other measures of alcohol, drug use, and risk behaviors) was self-administered on a tablet computer. A subsample (n = 186) was re-administered the NIAAA 2-question screen 1 week later to assess test-retest reliability. Moderate to good test-retest reliability was demonstrated. A classification of moderate risk or higher on the screen had the best combined sensitivity and specificity for determining a diagnosis of alcohol use disorder (AUD) for all students. Any past year drinking among middle school students increased the odds of a diagnosis of an AUD according to Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition criteria, whereas the optimal cutoff for high school ages was ≥3 drinking days in the past year. The optimal cutoff for drinking days determining a positive Alcohol Use Disorders Identification Test score among middle school subjects was ≥1 drinking day, whereas the optimal cutoff for high school subjects was ≥2 drinking days. The NIAAA 2-question screen is a brief, valid approach for alcohol screening in PEDs. A positive screen suggests that referral for further evaluation is indicated to determine if an adolescent has an AUD. Copyright © 2016 by the American Academy of Pediatrics.

  15. Reliability and Validity of a Two-Question Alcohol Screen in the Pediatric Emergency Department

    PubMed Central

    Spirito, Anthony; Bromberg, Julie R.; Casper, T. Charles; Chun, Thomas H.; Mello, Michael J.; Dean, J. Michael

    2016-01-01

    BACKGROUND AND OBJECTIVE: A multisite study was conducted to determine the psychometric properties of the National Institute of Alcohol Abuse and Alcoholism (NIAAA) 2-question alcohol screen within pediatric emergency departments (PEDs). METHODS: Participants (N = 4838) included 12- to 17-year-old subjects treated in 1 of the 16 participating PEDs across the United States. A criterion assessment battery (including the NIAAA 2-question alcohol screen and other measures of alcohol, drug use, and risk behaviors) was self-administered on a tablet computer. A subsample (n = 186) was re-administered the NIAAA 2-question screen 1 week later to assess test-retest reliability. RESULTS: Moderate to good test-retest reliability was demonstrated. A classification of moderate risk or higher on the screen had the best combined sensitivity and specificity for determining a diagnosis of alcohol use disorder (AUD) for all students. Any past year drinking among middle school students increased the odds of a diagnosis of an AUD according to Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition criteria, whereas the optimal cutoff for high school ages was ≥3 drinking days in the past year. The optimal cutoff for drinking days determining a positive Alcohol Use Disorders Identification Test score among middle school subjects was ≥1 drinking day, whereas the optimal cutoff for high school subjects was ≥2 drinking days. CONCLUSIONS: The NIAAA 2-question screen is a brief, valid approach for alcohol screening in PEDs. A positive screen suggests that referral for further evaluation is indicated to determine if an adolescent has an AUD. PMID:27940674

  16. A Comparison of the Approaches of Generalizability Theory and Item Response Theory in Estimating the Reliability of Test Scores for Testlet-Composed Tests

    ERIC Educational Resources Information Center

    Lee, Guemin; Park, In-Yong

    2012-01-01

    Previous assessments of the reliability of test scores for testlet-composed tests have indicated that item-based estimation methods overestimate reliability. This study was designed to address issues related to the extent to which item-based estimation methods overestimate the reliability of test scores composed of testlets and to compare several…

  17. Advanced Concept

    NASA Image and Video Library

    2008-02-15

    THIS IS A TEST OF THE 1ST STAGE RE-ENTRY VEHICLE. HEAT TESTING OF A 3% MODEL TO SUPPORT THE ARES/ CLV FIRST STAGE RE-ENTRY. THIS TEST OCCURRED AT ARNOLD AIR FORCE BASE, TENNESSEE. THIS TESTING SUPPORTS THE DEVELOPMENT OF THE CONSTELLATION/ARES PROJECT. THIS IMAGE IS EXTRACTED FROM A HIGH DEFINITION VIDEO FILE AND IS THE HIGHEST RESOLUTION AVAILABLE.

  18. HIFiRE Direct-Connect Rig (HDCR) Phase I Ground Test Results from the NASA Langley Arc-Heated Scramjet Test Facility

    NASA Technical Reports Server (NTRS)

    Hass, Neal E.; Cabell, Karen F.; Storch, Andrea M.

    2010-01-01

    The initial phase of hydrocarbon-fueled ground tests supporting Flight 2 of the Hypersonic International Flight Research Experiment (HIFiRE) Program has been conducted in the NASA Langley Arc-Heated Scramjet Test Facility (AHSTF). The HIFiRE Program, an Air Force-lead international cooperative program includes eight different flight test experiments designed to target specific challenges of hypersonic flight. The second of the eight planned flight experiments is a hydrocarbon-fueled scramjet flight test intended to demonstrate dual-mode to scramjet-mode operation and verify the scramjet performance prediction and design tools. A performance goal is the achievement of a combusted fuel equivalence ratio greater than 0.7 while in scramjet mode. The ground test rig, designated the HIFiRE Direct Connect Rig (HDCR), is a full-scale, heat sink, direct-connect ground test article that duplicates both the flowpath lines and the instrumentation layout of the isolator and combustor portion of the flight test hardware. The primary objectives of the HDCR Phase I tests are to verify the operability of the HIFiRE isolator/combustor across the Mach 6.0-8.0 flight regime and to establish a fuel distribution schedule to ensure a successful mode transition prior to the HiFIRE payload Critical Design Review. Although the phase I test plans include testing over the Mach 6 to 8 flight simulation range, only Mach 6 testing will be reported in this paper. Experimental results presented here include flowpath surface pressure, temperature, and heat flux distributions that demonstrate the operation of the flowpath over a small range of test conditions around the nominal Mach 6 simulation, as well as a range of fuel equivalence ratios and fuel injection distributions. Both ethylene and a mixture of ethylene and methane (planned for flight) were tested. Maximum back pressure and flameholding limits, as well as a baseline fuel schedule, that covers the Mach 5.84-6.5 test space have been identified.

  19. Basic Concepts in Classical Test Theory: Tests Aren't Reliable, the Nature of Alpha, and Reliability Generalization as a Meta-analytic Method.

    ERIC Educational Resources Information Center

    Helms, LuAnn Sherbeck

    This paper discusses the fact that reliability is about scores and not tests and how reliability limits effect sizes. The paper also explores the classical reliability coefficients of stability, equivalence, and internal consistency. Stability is concerned with how stable test scores will be over time, while equivalence addresses the relationship…

  20. Wafer level reliability testing: An idea whose time has come

    NASA Technical Reports Server (NTRS)

    Trapp, O. D.

    1987-01-01

    Wafer level reliability testing has been nurtured in the DARPA supported workshops, held each autumn since 1982. The seeds planted in 1982 have produced an active crop of very large scale integration manufacturers applying wafer level reliability test methods. Computer Aided Reliability (CAR) is a new seed being nurtured. Users are now being awakened by the huge economic value of the wafer reliability testing technology.

  1. The Cambridge Otology Quality of Life Questionnaire: an otology-specific patient-recorded outcome measure. A paper describing the instrument design and a report of preliminary reliability and validity.

    PubMed

    Martin, T P C; Moualed, D; Paul, A; Ronan, N; Tysome, J R; Donnelly, N P; Cook, R; Axon, P R

    2015-04-01

    The Cambridge Otology Quality of Life Questionnaire (COQOL) is a patient-recorded outcome measurement (PROM) designed to quantify the quality of life of patients attending otology clinics. Item-reduction model. A systematically designed long-form version (74 items) was tested with patient focus groups before being presented to adult otology patients (n. 137). Preliminary item analysis tested reliability, reducing the COQOL to 24 questions. This was then presented in conjunction with the SF-36 (V1) questionnaire to a total of 203 patients. Subsequently, these were re-presented at T + 3 months, and patients recorded whether they felt their condition had improved, deteriorated or remained the same. Non-responders were contacted by post. A correlation between COQOL scores and patient perception of change was examined to analyse content validity. Teaching hospital and university psychology department. Adult patients attending otology clinics with a wide range of otological conditions. Item reliability measured by item–total correlation, internal consistency and test– retest reliability. Validity measured by correlation between COQOL scores and patient-reported symptom change. Reliability: the COQOL showed excellent internal consistency at both initial presentation (a = 0.90) and 3 months later (a = 0.93). Validity: One-way analysis of variance showed a significant difference between groups reporting change and those reporting no change in quality of life (F(2, 80) = 5.866, P < 0.01). The COQOL is the first otology-specific PROM. Initial studies demonstrate excellent reliability and encouraging preliminary criterion validity: further studies will allow a deeper validation of the instrument.

  2. The validity and reliability of a dynamic neuromuscular stabilization-heel sliding test for core stability.

    PubMed

    Cha, Young Joo; Lee, Jae Jin; Kim, Do Hyun; You, Joshua Sung H

    2017-10-23

    Core stabilization plays an important role in the regulation of postural stability. To overcome shortcomings associated with pain and severe core instability during conventional core stabilization tests, we recently developed the dynamic neuromuscular stabilization-based heel sliding (DNS-HS) test. The purpose of this study was to establish the criterion validity and test-retest reliability of the novel DNS-HS test. Twenty young adults with core instability completed both the bilateral straight leg lowering test (BSLLT) and DNS-HS test for the criterion validity study and repeated the DNS-HS test for the test-retest reliability study. Criterion validity was determined by comparing hip joint angle data that were obtained from BSLLT and DNS-HS measures. The test-retest reliability was determined by comparing hip joint angle data. Criterion validity was (ICC2,3) = 0.700 (p< 0.05), suggesting a good relationship between the two core stability measures. Test-retest reliability was (ICC3,3) = 0.953 (p< 0.05), indicating excellent consistency between the repeated DNS-HS measurements. Criterion validity data demonstrated a good relationship between the gold standard BSLLT and DNS-HS core stability measures. Test-retest reliability data suggests that DNS-HS core stability was a reliable test for core stability. Clinically, the DNS-HS test is useful to objectively quantify core instability and allow early detection and evaluation.

  3. Advanced Key Technologies for Hot Control Surfaces in Space Re- Entry Vehicles

    NASA Astrophysics Data System (ADS)

    Dogigli, Michael; Pradier, Alain; Tumino, Giorgio

    2002-01-01

    (1)MAN Technologie AG, D- 86153 Augsburg, Germany (2,3) ESA, 2200 Noordwijk ZH, The Netherlands Current space re-entry vehicles (e.g. X-38 vehicle 201, the prototype of the International Space Station's Crew Return Vehicle (CRV)) require advanced control surfaces (so called body flaps). Such control surfaces allow the design of smaller and lighter vehicles as well as faster re-entries (compared to the US Shuttle). They are designed as light-weight structures that need no metallic parts, need no mass or volume consuming heat sinks to protect critical components (e.g. bearings) and that can be operated at temperatures of more than 1600 "C in air transferring high mechanical loads (dynamic 40 kN, static 70 kN) at the same time. Because there is a need for CRV and also for Reusable Launch Vehicles (RLV) in future, the European Space Agency (ESA) felt compelled to establish a "Future European Space Transportation and Investigation Program,, (FESTIP) and a "General Support for Technology Program,, (GSTP). One of the main goals of these programs was to develop and qualify key-technologies that are able to master the above mentioned challenging requirements for advanced hot control surfaces and that can be applied for different vehicles. In 1996 MAN Technologie has started the development of hot control surfaces for small lifting bodies in the national program "Heiü Strukturen,,. One of the main results of this program was that especially the following CMC (Ceramic Matrix Composite) key technologies need to be brought up to space flight standard: Complex CMC Structures, CMC Bearings, Metal-to-CMC Joining Technologies, CMC Fasteners, Oxidation Protection Systems and Static and Dynamic Seals. MAN Technologie was contracted by ESA to continue the development and qualification of these key technologies in the frame of the FESTIP and the GSTP program. Development and qualification have successfully been carried out. The key technologies have been applied for the X-38 vehicle 201 body flaps that have been designed, manufactured and qualified also by MAN Technologie in the frame of the national TETRA program ("Technologien fu zuku ftige Raum-Transportsysteme,,). A set of two body flaps will be delivered to NASA at the beginning of 2002 to be integrated into the vehicle 201. Based on development- and qualification tests, the paper describes main technical properties and features of these key technologies that at the same time represent the status of the art. In a qualification test (simultaneous application of thermal and mechanical loads with bearing movements in oxidising atmosphere) of a full scaled CMC bearing, five complete re-entries have been simulated successfully. The paper informs about applied mechanical load and temperature histories as well as about the number of intermittent bearing movements. The paper further informs about the complex CMC attachment structures (attachment of bearing into the body flap and load introduction) that have been qualified together with the CMC bearing. The attachment of the body flap to the vehicle's aft structure has also been qualified by tests in which also four re- entries have been simulated successfully. The attachment in principle is an interfacing structure between the "hot" (1600 "C) CMC body flap and the "cold,, (175 "C) metallic vehicle's aft structure that is able to transfer high me- chanical loads at high temperatures and minimise the heat flux through interfacing components in such way that the temperature difference of 1600 "C 175 "C = 1425 "C is brought down over a structure-length of only 200 mm. The paper informs about applied mechanical load and temperature histories and about the safety margins that have been demonstrated by rupture tests. Mechanical load carrying capacity and thermal resistance of ceramic fasteners have been demonstrated in several development tests which cover tension-, shear-, fatigue- and self locking-tests as well as tests with fastener assemblies representative for the body flaps. The reliability of these fasteners has also been demonstrated in the bearing and body flap qualification tests. In a comprehensive development test campaign, oxidation protection systems as well as repair methods have been developed and successfully applied for the body flap structure and components that reliably can be protected at least for four re-entries. The development of key technologies is continued in the national ASTRA program ("Basistechnologien fu keramische Hochtemperatur-Komponenten,,) and in international programs that among others focus on to improve the reusability of high temperature CMC components for RLVs.

  4. NASA Tech Briefs, May 2013

    NASA Technical Reports Server (NTRS)

    2013-01-01

    Topics include: Test Waveform Applications for JPL STRS Operating Environment; Pneumatic Proboscis Heat-Flow Probe; Method to Measure Total Noise Temperature of a Wireless Receiver During Operation; Cursor Control Device Test Battery; Functional Near-Infrared Spectroscopy Signals Measure Neuronal Activity in the Cortex; ESD Test Apparatus for Soldering Irons; FPGA-Based X-Ray Detection and Measurement for an X-Ray Polarimeter; Sequential Probability Ratio Test for Spacecraft Collision Avoidance Maneuver Decisions; Silicon/Carbon Nanotube Photocathode for Splitting Water; Advanced Materials and Fabrication Techniques for the Orion Attitude Control Motor; Flight Hardware Packaging Design for Stringent EMC Radiated Emission Requirements; RF Reference Switch for Spaceflight Radiometer Calibration; An Offload NIC for NASA, NLR, and Grid Computing; Multi-Scale CNT-Based Reinforcing Polymer Matrix Composites for Lightweight Structures; Ceramic Adhesive and Methods for On-Orbit Repair of Re-Entry Vehicles; Self-Healing Nanocomposites for Reusable Composite Cryotanks; Pt-Ni and Pt-Co Catalyst Synthesis Route for Fuel Cell Applications; Aerogel-Based Multilayer Insulation with Micrometeoroid Protection; Manufacturing of Nanocomposite Carbon Fibers and Composite Cylinders; Optimized Radiator Geometries for Hot Lunar Thermal Environments; A Mission Concept: Re-Entry Hopper-Aero-Space-Craft System on-Mars (REARM-Mars); New Class of Flow Batteries for Terrestrial and Aerospace Energy Storage Applications; Reliability of CCGA 1152 and CCGA 1272 Interconnect Packages for Extreme Thermal Environments; Using a Blender to Assess the Microbial Density of Encapsulated Organisms; Mixed Integer Programming and Heuristic Scheduling for Space Communication; Video Altimeter and Obstruction Detector for an Aircraft; Control Software for Piezo Stepping Actuators; Galactic Cosmic Ray Event-Based Risk Model (GERM) Code; Sasquatch Footprint Tool; and Multi-User Space Link Extension (SLE) System.

  5. Test Reliability at the Individual Level

    PubMed Central

    Hu, Yueqin; Nesselroade, John R.; Erbacher, Monica K.; Boker, Steven M.; Burt, S. Alexandra; Keel, Pamela K.; Neale, Michael C.; Sisk, Cheryl L.; Klump, Kelly

    2016-01-01

    Reliability has a long history as one of the key psychometric properties of a test. However, a given test might not measure people equally reliably. Test scores from some individuals may have considerably greater error than others. This study proposed two approaches using intraindividual variation to estimate test reliability for each person. A simulation study suggested that the parallel tests approach and the structural equation modeling approach recovered the simulated reliability coefficients. Then in an empirical study, where forty-five females were measured daily on the Positive and Negative Affect Schedule (PANAS) for 45 consecutive days, separate estimates of reliability were generated for each person. Results showed that reliability estimates of the PANAS varied substantially from person to person. The methods provided in this article apply to tests measuring changeable attributes and require repeated measures across time on each individual. This article also provides a set of parallel forms of PANAS. PMID:28936107

  6. Demonstrating the Safety and Reliability of a New System or Spacecraft: Incorporating Analyses and Reviews of the Design and Processing in Determining the Number of Tests to be Conducted

    NASA Technical Reports Server (NTRS)

    Vesely, William E.; Colon, Alfredo E.

    2010-01-01

    Design Safety/Reliability is associated with the probability of no failure-causing faults existing in a design. Confidence in the non-existence of failure-causing faults is increased by performing tests with no failure. Reliability-Growth testing requirements are based on initial assurance and fault detection probability. Using binomial tables generally gives too many required tests compared to reliability-growth requirements. Reliability-Growth testing requirements are based on reliability principles and factors and should be used.

  7. Influences on and Limitations of Classical Test Theory Reliability Estimates.

    ERIC Educational Resources Information Center

    Arnold, Margery E.

    It is incorrect to say "the test is reliable" because reliability is a function not only of the test itself, but of many factors. The present paper explains how different factors affect classical reliability estimates such as test-retest, interrater, internal consistency, and equivalent forms coefficients. Furthermore, the limits of classical test…

  8. Intertester and intratester reliability of a movement control test battery for patients with knee osteoarthritis and controls

    PubMed Central

    Kaukinen, P.T.; Arokoski, J.P.; Huber, E.O.; Luomajoki, H.A.

    2017-01-01

    Objectives: To develop a test battery of movement control (MC) tests and assess its intertester and intratester reliability. Methods: 29 subjects with knee OA with mean age of 64.7 (SD 8.7) years and 12 controls without either knee pain or previous diagnosis of OA (mean age 36.6 (SD 16.2) years) were included. Two experienced physiotherapists rated the filmed test performance of six MC tests blinded to the patients and to each other on 3-point scale as correct, incorrect or failed. Weighted kappa coefficient (wK) with 95% confidence interval (95%CI) and the percentage of agreement were calculated for each test. Results: One-leg stance, one-leg squat 30 degrees and step down tests showed moderate to excellent inter- and intratester reliability with wK ranging between 0.43-0.85 for intertester and 0.51-0.80 for intratester reliability. The reliability of the 90 degrees squat test, small squat and step up tests was poor (wK ranging between 0.09-0.50). Conclusions: One-leg stance test, one-leg squat 30 degrees and step down test are reliable in the subjects with knee OA and controls. Further studies are needed to evaluate the discriminative validity of the reliable tests. PMID:28860422

  9. Constitutive Modeling of a Glass Fiber-Reinforced PTFE Gasketed-Joint Under a Re-torque

    NASA Astrophysics Data System (ADS)

    Williams, James; Gordon, Ali P.

    Joints gasketed with viscoelastic seals often receive an application of a secondary torque, i.e., retorque, in order to ensure joint tightness and proper sealing. The motivation of this study is to characterize and analytically model the load and deflection re-torque response of a single 25% glass-fiber reinforced polytetrafluorethylene (PTFE) gasket-bolted joint with serrated flange detail. The Burger-type viscoelastic modeling constants of the material are obtained through isolating the gasket from the bolt by performing a gasket creep test via a MTS electromechanical test frame. The re-load creep response is also investigated by re-loading the gasket after a period of initial creep to observe the response. The modeling constants obtained from the creep tests are used with a Burger-type viscoelastic model to predict the re-torque response of a single bolt-gasket test fixture in order to validate the ability of the model to simulate the re-torque response under various loading conditions and flange detail.

  10. Test – Retest Reliability and Concurrent Validity of in vivo Myelin Content Indices: Myelin Water Fraction and Calibrated T1w/T2w Image Ratio

    PubMed Central

    Arshad, Muzamil; Stanley, Jeffrey A.; Raz, Naftali

    2016-01-01

    In an age-heterogeneous sample of healthy adults, we examined test-retest reliability (with and without participant re-positioning) of two popular MRI methods of estimating myelin content: modeling the short spin-spin (T2) relaxation component of multi-echo imaging data and computing the ratio of T1-weighted and T2-weighted images (T1w/T2w). Taking the myelin water fraction (MWF) index of myelin content derived from the multi-component T2 relaxation data as a standard, we evaluate the concurrent and differential validity of T1w/T2w ratio images. The results revealed high reliability of MWF and T1w/T2w ratio. However, we found significant correlations of low to moderate magnitude between MWF and the T1w/T2w ratio in only two of six examined regions of the cerebral white matter. Notably, significant correlations of the same or greater magnitude were observed for T1w/T2w ratio and the intermediate T2 relaxation time constant, which is believed to reflect differences in the mobility of water between the intracellular and extracellular compartments. We conclude that although both methods are highly reliable and thus well-suited for longitudinal studies, T1w/T2w ratio has low criterion validity and may be not an optimal index of subcortical myelin content. PMID:28009069

  11. Cross-cultural adaptation and validation of the Injury-Psychological Readiness to Return to Sport scale to Persian language.

    PubMed

    Naghdi, Soofia; Nakhostin Ansari, Noureddin; Farhadi, Yasaman; Ebadi, Safoora; Entezary, Ebrahim; Glazer, Douglas

    2016-10-01

    The aim of the present study was to develop and provide validation statistics for the Persian Injury-Psychological Readiness to Return to Sport scale (I-PRRS) following a cross-sectional and prospective cohort study design. The I-PRRS was forward/back-translated and culturally adapted into Persian language. The Persian I-PRRS was administered to 100 injured athletes (93 male; age 26.0 ± 5.6 years; time since injury 4.84 ± 6.4 months) and 50 healthy athletes (36 male; mean age 25.7 ± 6.0 years). The Persian I-PRRS was re-administered to 50 injured athletes at 1 week to examine test-retest reliability. There were no floor or ceiling effects confirming the content validity of Persian I-PRRS. The internal consistency reliability was good. Excellent test-retest reliability and agreement were demonstrated. The statistically significant difference in Persian I-PRRS total scores between the injured athletes and healthy athletes provides an evidence of discriminative validity. The Persian I-PRRS total scores were positively correlated with the Farsi Mood Scale (FARMS) total scores, showing construct validity. The principal component analysis indicated a two-factor solution consisting of "Confidence to play" and "Confidence in the injured body part and skill level". The Persian I-PRRS showed excellent reliability and validity and can be used to assess injured athletes' psychological readiness to return to sport among Persian-speaking populations.

  12. Radiant Heat Testing of the H1224A Shipping/Storage Container

    DTIC Science & Technology

    1994-05-01

    re - entry vehicles caused by credible accidents during air and ground transportation. Radiant heat testing of the H1224A storage/shipping container is...inner container, and re - entry vehicle (RV) temperatures during radiant heat testing. Computer modelling can be used to predict weapon response throughout...Nomenclature RV Re - entry Vehicle midsection mass mock-up WR War Reserve STS Stockpile-to-Target Sequence NAWC Simulated H1224A container by Naval Air

  13. Experimental investigation and damage assessment in a post tensioned concrete beam

    NASA Astrophysics Data System (ADS)

    Limongelli, Maria; Siegert, Dominique; Merliot, Erick; Waeytens, Julien; Bourquin, Frederic; Vidal, Roland; Le Corvec, Veronique; Guegen, Ivan; Cottineau, Louis-Marie

    2017-04-01

    This paper presents the results of an experimental campaign carried out on a prestressed concrete beam in the realm of the project SIPRIS (Systèmes Intelligents pour la Prévention des Risques Structurels), aimed to develop intelligent systems for the prevention of structural risk related to the aging of large infrastructures. The specimen was tested in several configurations aimed to re-produce several different phases of the 'life' of the beam: in the original undamaged state, under an increasing loss of tension in the cables, during and after cracking induced by a point load, after a strengthening intervention, after new cracking of the 'repaired' beam. Damage was introduced in a controlled way by means of three-point static bending tests. The transverse point loads were ap-plied at several different sections along the beam axis. Before and after each static test, the dy-namical response of the beam was measured under sine-sweep and impact tests by an extensive set of accelerometers deployed along the beam axis. The availability of both static and dynamic tests allows to investigate and compare their effectiveness to detect damages in the tensioned beam and to reliably identify the evolution of damage. The paper discusses the tests program and some results relevant to the dynamic characterization of the beam in the different phases.

  14. Visual Search as a Tool for a Quick and Reliable Assessment of Cognitive Functions in Patients with Multiple Sclerosis

    PubMed Central

    Utz, Kathrin S.; Hankeln, Thomas M. A.; Jung, Lena; Lämmer, Alexandra; Waschbisch, Anne; Lee, De-Hyung; Linker, Ralf A.; Schenk, Thomas

    2013-01-01

    Background Despite the high frequency of cognitive impairment in multiple sclerosis, its assessment has not gained entrance into clinical routine yet, due to lack of time-saving and suitable tests for patients with multiple sclerosis. Objective The aim of the study was to compare the paradigm of visual search with neuropsychological standard tests, in order to identify the test that discriminates best between patients with multiple sclerosis and healthy individuals concerning cognitive functions, without being susceptible to practice effects. Methods Patients with relapsing remitting multiple sclerosis (n = 38) and age-and gender-matched healthy individuals (n = 40) were tested with common neuropsychological tests and a computer-based visual search task, whereby a target stimulus has to be detected amongst distracting stimuli on a touch screen. Twenty-eight of the healthy individuals were re-tested in order to determine potential practice effects. Results Mean reaction time reflecting visual attention and movement time indicating motor execution in the visual search task discriminated best between healthy individuals and patients with multiple sclerosis, without practice effects. Conclusions Visual search is a promising instrument for the assessment of cognitive functions and potentially cognitive changes in patients with multiple sclerosis thanks to its good discriminatory power and insusceptibility to practice effects. PMID:24282604

  15. The reliability of physical examination tests for the diagnosis of anterior cruciate ligament rupture--A systematic review.

    PubMed

    Lange, Toni; Freiberg, Alice; Dröge, Patrik; Lützner, Jörg; Schmitt, Jochen; Kopkow, Christian

    2015-06-01

    Systematic literature review. Despite their frequent application in routine care, a systematic review on the reliability of clinical examination tests to evaluate the integrity of the ACL is missing. To summarize and evaluate intra- and interrater reliability research on physical examination tests used for the diagnosis of ACL tears. A comprehensive systematic literature search was conducted in MEDLINE, EMBASE and AMED until May 30th 2013. Studies were included if they assessed the intra- and/or interrater reliability of physical examination tests for the integrity of the ACL. Methodological quality was evaluated with the Quality Appraisal of Reliability Studies (QAREL) tool by two independent reviewers. 110 hits were achieved of which seven articles finally met the inclusion criteria. These studies examined the reliability of four physical examination tests. Intrarater reliability was assessed in three studies and ranged from fair to almost perfect (Cohen's k = 0.22-1.00). Interrater reliability was assessed in all included studies and ranged from slight to almost perfect (Cohen's k = 0.02-0.81). The Lachman test is the physical tests with the highest intrarater reliability (Cohen's k = 1.00), the Lachman test performed in prone position the test with the highest interrater reliability (Cohen's k = 0.81). Included studies were partly of low methodological quality. A meta-analysis could not be performed due to the heterogeneity in study populations, reliability measures and methodological quality of included studies. Systematic investigations on the reliability of physical examination tests to assess the integrity of the ACL are scarce and of varying methodological quality. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. PILOT PLANT TESTING OF ELEMENTAL MERCURY RE-EMISSION FROM WET SCRUBBERS

    EPA Science Inventory

    A pilot-scale wet lime/limestone flue gas desulfurization scrubber system was designed to conduct mercury emission control research. The first tests focused on investigating the phenomenon of Hgo re-emission from wet scrubbers with a specific objective of developing a Hgo re-emis...

  17. Reliability of a Computerized Neurocognitive Test in Baseline Concussion Testing of High School Athletes.

    PubMed

    MacDonald, James; Duerson, Drew

    2015-07-01

    Baseline assessments using computerized neurocognitive tests are frequently used in the management of sport-related concussions. Such testing is often done on an annual basis in a community setting. Reliability is a fundamental test characteristic that should be established for such tests. Our study examined the test-retest reliability of a computerized neurocognitive test in high school athletes over 1 year. Repeated measures design. Two American high schools. High school athletes (N = 117) participating in American football or soccer during the 2011-2012 and 2012-2013 academic years. All study participants completed 2 baseline computerized neurocognitive tests taken 1 year apart at their respective schools. The test measures performance on 4 cognitive tasks: identification speed (Attention), detection speed (Processing Speed), one card learning accuracy (Learning), and one back speed (Working Memory). Reliability was assessed by measuring the intraclass correlation coefficient (ICC) between the repeated measures of the 4 cognitive tasks. Pearson and Spearman correlation coefficients were calculated as a secondary outcome measure. The measure for identification speed performed best (ICC = 0.672; 95% confidence interval, 0.559-0.760) and the measure for one card learning accuracy performed worst (ICC = 0.401; 95% confidence interval, 0.237-0.542). All tests had marginal or low reliability. In a population of high school athletes, computerized neurocognitive testing performed in a community setting demonstrated low to marginal test-retest reliability on baseline assessments 1 year apart. Further investigation should focus on (1) improving the reliability of individual tasks tested, (2) controlling for external factors that might affect test performance, and (3) identifying the ideal time interval to repeat baseline testing in high school athletes. Computerized neurocognitive tests are used frequently in high school athletes, often within a model of baseline testing of asymptomatic individuals before the start of a sporting season. This study adds to the evidence that suggests in this population such testing may lack sufficient reliability to support clinical decision making.

  18. Is retrieval the key? Metamemory judgment and testing as learning strategies.

    PubMed

    Akdoğan, Elçin; Izaute, Marie; Danion, Jean-Marie; Vidailhet, Pierre; Bacon, Elisabeth

    2016-11-01

    Re-reading is the most common learning strategy, albeit not a very efficient one. Testing is highly efficient, but not perceived by students as a learning strategy. Prospective judgment-of-learning (JOL) reflect the learner's impression of subsequently being able to retrieve the ongoing learning in a cued-recall task. Estimating JOL involves attempting to retrieve the information, as in testing. The few studies that have explored the potential mnemonic benefit of JOL have yielded contradictory results. Our aim was to compare JOL and testing with re-study and to examine the impact of these strategies according to the relative difficulty of the material (cue-target association strength) in two experiments. After a first encoding phase, participants re-studied, provided JOL, or took a test. Forty-eight hours later, they participated in a final cued-recall test, during which their confidence level judgments were collected. The main result was that delayed JOL behaved in the same way as testing, and both yielded better performances than re-study when material was of moderate difficulty. The easy or very difficult material revealed no differences between these strategies. JOL is proposed as an alternative to testing when faced with difficult material.

  19. Gall-bladder and colonic retention of SeHCAT: a re-evaluation.

    PubMed

    Merrick, M V

    1994-09-01

    A number of suggested alternatives and emendations to the 7-day SeHCAT retention test have been compared with whole-body counting. It was found that correction for colonic retention is an unnecessary complication in patients with diarrhoea and that imaging either of the gall-bladder or of the distribution of activity in the intestines at 24 h does not add useful information to the standard 7-day retention measurement. Neither could the patterns of colonic uptake identified in patients following extensive ideal resection or radiotherapy be reproduced in patients with idiopathic diarrhoea. Sadly it must be concluded that neither of these shortened techniques is of clinical value in patients with intact small bowel and that there remains no reliable alternative to the 7-day Se HCAT retention test. The simplest technique the best.

  20. The Swedish version of the Ritvo autism and asperger diagnostic scale: revised (RAADS-R). A validation study of a rating scale for adults.

    PubMed

    Andersen, Lisa M J; Näswall, Katharina; Manouilenko, Irina; Nylander, Lena; Edgar, Johan; Ritvo, Riva Ariella; Ritvo, Edward; Bejerot, Susanne

    2011-12-01

    There is a paucity of diagnostic instruments for adults with autism spectrum disorder (ASD). This study evaluates the psychometric properties of the Swedish version of the Ritvo Autism and Asperger Diagnostic Scale-Revised (RAADS-R), an 80-item self-rating scale designed to assist clinicians diagnosing ASD in adults. It was administered to 75 adults with ASD and 197 comparison cases. Also, a subset completed the Autism Spectrum Quotient (AQ). Three out of four subscales had high internal consistency. Sensitivity was 91% and specificity was 93%. The ASD subjects had significantly higher mean scores on all subscales. ASD females had higher scores than ASD males on the sensory motor subscale, a dimension not included in the AQ. RAADS-R showed promising test re-test reliability.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Altazi, B; Fernandez, D; Zhang, G

    Purpose: Site-specific investigations of the role of Radiomics in cancer diagnosis and therapy are needed. We report of the reproducibility of quantitative image features over different discrete voxel levels in PET/CT images of cervical cancer. Methods: Our dataset consisted of the pretreatment PET/CT scans from a cohort of 76 patients diagnosed with cervical cancer, FIGO stage IB-IVA, age range 31–76 years, treated with external beam radiation therapy to a dose range between 45–50.4 Gy (median dose: 45 Gy), concurrent cisplatin chemotherapy and MRI-based Brachytherapy to a dose of 20–30 Gy (median total dose: 28 Gy). Two board certified radiation oncologistsmore » delineated Metabolic Tumor volume (MTV) for each patient. Radiomics features were extracted based on 32, 64, 128 and 256 discretization levels (DL). The 64 level was chosen to be the reference DL. Features were calculated based on Co-occurrence (COM), Gray Level Size Zone (GLSZM) and Run-Length (RLM) matrices. Mean Percentage Differences (Δ) of features for discrete levels were determined. Normality distribution of Δ was tested using Kolomogorov - Smirnov test. Bland-Altman test was used to investigate differences between feature values measured on different DL. The mean, standard deviation and upper/lower value limits for each pair of DL were calculated. Interclass Correlation Coefficient (ICC) analysis was performed to examine the reliability of repeated measures within the context of the test re-test format. Results: 3 global and 5 regional features out of 48 features showed distribution not significantly different from a normal one. The reproducible features passed the normality test. Only 5 reproducible results were reliable, ICC range 0.7 – 0.99. Conclusion: Most of the radiomics features tested showed sensitivity to voxel level discretization between (32 – 256). Only 4 GLSZM, 3 COM and 1 RLM showed insensitivity towards mentioned discrete levels.« less

  2. Reliability of the Test of Integrated Language and Literacy Skills (TILLS)

    ERIC Educational Resources Information Center

    Mailend, Marja-Liisa; Plante, Elena; Anderson, Michele A.; Applegate, E. Brooks; Nelson, Nickola W.

    2016-01-01

    Background: As new standardized tests become commercially available, it is critical that clinicians have access to the information about a test's psychometric properties, including aspects of reliability. Aims: The purpose of the three studies reported in this article was to investigate the reliability of a new test, the Test of Integrated…

  3. Locking Nut with Stress-Distributing Insert

    NASA Technical Reports Server (NTRS)

    Daniels, Christopher C.

    2010-01-01

    Reusable holders have been devised for evaluating high-temperature, plasma-resistant re-entry materials, especially fabrics. Typical material samples tested support thermal-protection-system damage repair requiring evaluation prior to re-entry into terrestrial atmosphere. These tests allow evaluation of each material to withstand the most severe predicted re-entry conditions.

  4. Translation and psychometric assessment of the Persian version of the Rhodes Index of Nausea, Vomiting and Retching (INVR) scale for the assessment of chemotherapy-induced nausea and vomiting.

    PubMed

    Moradian, S; Shahidsales, S; Ghavam Nasiri, M R; Pilling, M; Molassiotis, A; Walshe, C

    2014-11-01

    No tools are available to assess or measure the experience of chemotherapy-induced nausea and vomiting (CINV) for Persian/Farsi speakers. The purpose of this study is to translate the Rhodes Index of Nausea, Vomiting and Retching (INVR) scale for use with Persian-speaking cancer patients. A sample of 94 cancer patients were recruited from a cancer research centre in Mashhad-Iran. A standard two phase process of scale translation and validation was conducted. In phase I, standard 'forward-backward' translation procedure was used to translate the original version of the INVR questionnaire into Persian. The translated questionnaire was reviewed and revised and a Persian version of the scale was produced. In the second phase, a multiphase instrumentation study describing the internal consistency and test-retest reliability of the translated version was conducted. The inter-item correlation measured by Cronbach's alpha was 0.88. Test/re-test reliability was measured by the weighted kappa and was between 0.63 and 0.79, indicating 'substantial agreement' and stability between the initial and subsequent administrations for each item. These results demonstrate that the Persian version of the INVR is acceptable for use among Iranian cancer patients. Researchers could use this study as a model for future translation and application of psychometric instrumentation. © 2013 John Wiley & Sons Ltd.

  5. Vestibular Assessments in Children With Global Developmental Delay: An Exploratory Study.

    PubMed

    Dannenbaum, Elizabeth; Horne, Victoria; Malik, Farwa; Villeneuve, Myriam; Salvo, Lora; Chilingaryan, Gevorg; Lamontagne, Anouk

    2016-01-01

    To compare results of 3 clinical vestibular tests between children with global developmental delay (GDD) and children with typical development (TD) and investigate the test-retest reliability. Twenty children with GDD (aged 4.1-12.1 years) and 11 age-matched controls with TD participated. Participants with GDD underwent 2 sessions of testing. Each session consisted of the Clinical Test of Sensory Interaction and Balance (CTSIB), Dynamic Visual Acuity (DVA) test, and the modified Emory Clinical Vestibular Chair Test (m-ECVCT). Up to 33% of the children with GDD had abnormal DVA scores. m-ECVCT results of children with GDD demonstrated larger variance than children with TD. The CTSIB score was significantly reduced in the group with GDD. The test-retest reliability varied, with good reliability for the m-ECVCT and CTSIB, and fair reliability for the DVA. Findings suggest vestibular involvement in children in GDD. The clinical tests demonstrated moderate test-retest reliability.

  6. Test-retest and inter- and intrareliability of the quality of the upper-extremity skills test in preschool-age children with cerebral palsy.

    PubMed

    Haga, Nienke; van der Heijden-Maessen, Hélène C; van Hoorn, Jessika F; Boonstra, Anne M; Hadders-Algra, Mijna

    2007-12-01

    To investigate the test-retest, inter-, and intraobserver reliability of the Quality of Upper Extremity Skills Test (QUEST) in young children with cerebral palsy (CP). For test-retest reliability, a test-retest design was used; for the intra- and interobserver reliability, the videotaped test was scored on 2 occasions by 1 observer and by various observers. Groups of preschool-age children in 2 general rehabilitation centers. Twenty-one children with CP (12 boys, 9 girls) aged 2 to 4.5 years (mean, 39 mo). Not applicable. Spearman correlation coefficient. The data indicated that test-retest reliability was strong (rho range, .85-.94). Intraobserver agreement (rho range, .63-.95) and agreement between various observers (rho range, .72-.90) were moderate to strong. Test-retest and inter- and intraobserver reliability of the QUEST in preschool-age children with CP is good.

  7. Test-retest reliability of infant event related potentials evoked by faces.

    PubMed

    Munsters, N M; van Ravenswaaij, H; van den Boomen, C; Kemner, C

    2017-04-05

    Reliable measures are required to draw meaningful conclusions regarding developmental changes in longitudinal studies. Little is known, however, about the test-retest reliability of face-sensitive event related potentials (ERPs), a frequently used neural measure in infants. The aim of the current study is to investigate the test-retest reliability of ERPs typically evoked by faces in 9-10 month-old infants. The infants (N=31) were presented with neutral, fearful and happy faces that contained only the lower or higher spatial frequency information. They were tested twice within two weeks. The present results show that the test-retest reliability of the face-sensitive ERP components is moderate (P400 and Nc) to substantial (N290). However, there is low test-retest reliability for the effects of the specific experimental manipulations (i.e. emotion and spatial frequency) on the face-sensitive ERPs. To conclude, in infants the face-sensitive ERP components (i.e. N290, P400 and Nc) show adequate test-retest reliability, but not the effects of emotion and spatial frequency on these ERP components. We propose that further research focuses on investigating elements that might increase the test-retest reliability, as adequate test-retest reliability is necessary to draw meaningful conclusions on individual developmental trajectories of the face-sensitive ERPs in infants. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  8. Reliability of the Berg Balance Scale as a Clinical Measure of Balance in Community-Dwelling Older Adults with Mild to Moderate Alzheimer Disease: A Pilot Study.

    PubMed

    Muir-Hunter, Susan W; Graham, Laura; Montero Odasso, Manuel

    2015-08-01

    To measure test-retest and interrater reliability of the Berg Balance Scale (BBS) in community-dwelling adults with mild to moderate Alzheimer disease (AD). Method : A sample of 15 adults (mean age 80.20 [SD 5.03] years) with AD performed three balance tests: the BBS, timed up-and-go test (TUG), and Functional Reach Test (FRT). Both relative reliability, using the intra-class correlation coefficient (ICC), and absolute reliability, using standard error of measurement (SEM) and minimal detectable change (MDC95) values, were calculated; Bland-Altman plots were constructed to evaluate inter-tester agreement. The test-retest interval was 1 week. Results : For the BBS, relative reliability values were 0.95 (95% CI, 0.85-0.98) for test-retest reliability and 0.72 (95% CI, 0.31-0.91) for interrater reliability; SEM was 6.01 points and MDC95 was 16.66 points; and interrater agreement was 16.62 points. The BBS performed better in test-retest reliability than the TUG and FRT, tests with established reliability in AD. Between 33% and 50% of participants required cueing beyond standardized instructions because they were unable to remember test instructions. Conclusions : The BBS achieved relative reliability values that support its clinical utility, but MDC95 and agreement values indicate the scale has performance limitations in AD. Further research to optimize balance assessment for people with AD is required.

  9. Reliability of the Melbourne assessment of unilateral upper limb function.

    PubMed

    Randall, M; Carlin, J B; Chondros, P; Reddihough, D

    2001-11-01

    This study examines the reliability of the Melbourne Assessment of Unilateral Upper Limb Function: a quantitative test of quality of movement in children with neurological impairment. The assessment was administered to 20 children aged from 5 to 16 years (mean age 9 years 10 months, SD 2 years 10 months) who had various types and degrees of cerebral palsy (CP). The performances of the 20 children during assessment were videotaped for subsequent scoring by 15 occupational therapists. Scores were analyzed for internal consistency of test items, inter- and intrarater reliability of scorings of the same videotapes, and test-retest reliability using repeat videotaping. Results revealed very high internal consistency of test items (alpha=0.96), moderate to high agreement both within and between raters for all test items (intraclass correlations of at least 0.7) apart from item 16 (hand to mouth and down), and high interrater reliability (0.95) and intrarater reliability (0.97) for total test scores. Test-retest results revealed moderate to high intrarater reliability for item totals (mean of 0.83 and 0.79) for each rater and high reliability for test totals (0.98 and 0.97). These findings indicate that the Melbourne Assessment of Unilateral Upper Limb Function is a reliable tool for measuring the quality of unilateral upper-limb movement in children with CP.

  10. The role of test-retest reliability in measuring individual and group differences in executive functioning.

    PubMed

    Paap, Kenneth R; Sawi, Oliver

    2016-12-01

    Studies testing for individual or group differences in executive functioning can be compromised by unknown test-retest reliability. Test-retest reliabilities across an interval of about one week were obtained from performance in the antisaccade, flanker, Simon, and color-shape switching tasks. There is a general trade-off between the greater reliability of single mean RT measures, and the greater process purity of measures based on contrasts between mean RTs in two conditions. The individual differences in RT model recently developed by Miller and Ulrich was used to evaluate the trade-off. Test-retest reliability was statistically significant for 11 of the 12 measures, but was of moderate size, at best, for the difference scores. The test-retest reliabilities for the Simon and flanker interference scores were lower than those for switching costs. Standard practice evaluates the reliability of executive-functioning measures using split-half methods based on data obtained in a single day. Our test-retest measures of reliability are lower, especially for difference scores. These reliability measures must also take into account possible day effects that classical test theory assumes do not occur. Measures based on single mean RTs tend to have acceptable levels of reliability and convergent validity, but are "impure" measures of specific executive functions. The individual differences in RT model shows that the impurity problem is worse than typically assumed. However, the "purer" measures based on difference scores have low convergent validity that is partly caused by deficiencies in test-retest reliability. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Reliability of the Timed Up and Go test and Ten-Metre Timed Walk Test in Pregnant Women with Pelvic Girdle Pain.

    PubMed

    Evensen, Natalie M; Kvåle, Alice; Braekken, Ingeborg H

    2015-09-01

    There is a lack of functional objective tests available to measure functional status in women with pelvic girdle pain (PGP). The purpose of this study was to establish test-retest and intertester reliability of the Timed Up and Go (TUG) test and Ten-metre Timed Walk Test (10mTWT) in pregnant women with PGP. A convenience sample of women was recruited over a 4-month period and tested on two occasions, 1 week apart to determine test-retest reliability. Intertester reliability was established between two assessors at the first testing session. Subjects were instructed to undertake the TUG and 10mTWT at maximum speed. One practise trial and two timed trials for each walking test was undertaken on Day 1 and one practise trial and one timed trial on Day 2. Seventeen women with PGP aged 31.1 years (SD [standard deviation] = 2.3) and 28.7 weeks pregnant (SD = 7.4) completed gait testing. Test-retest reliability using the intraclass correlation coefficient (ICC) was excellent for the TUG (0.88) and good for the 10mTWT (0.74). Intertester reliability was determined in the first 13 participants with excellent ICC values being found for both walking tests (TUG: 0.95; 10mTWT: 0.94). This study demonstrated that the TUG and 10mTWT undertaken at fast pace are reliable, objective functional tests in pregnant women with PGP. While both tests are suitable for use in the clinical and research settings, we would recommend the TUG given the findings of higher test-retest reliability and as this test requires less space and time to set up and score. Future studies in a larger sample size are warranted to confirm the results of this study. Copyright © 2015 John Wiley & Sons, Ltd.

  12. Anisomycin Infused into the Hippocampus Fails to Block "Reconsolidation" but Impairs Extinction: The Role of Re-Exposure Duration

    ERIC Educational Resources Information Center

    McGaugh, James L.; Steward, Oswald; Power, Ann E.; Berlau, Daniel J.

    2006-01-01

    Recent studies have reported new evidence consistent with the hypothesis that reactivating a memory by re-exposure to a training context destabilizes the memory and induces "reconsolidation." In the present experiments, rats' memory for inhibitory avoidance (IA) training was tested 6 h (Test 1), 2 d (Test 2), and 6 d (Test 3) after training. On…

  13. 75 FR 50853 - Special Conditions: Cirrus Design Corporation Model SF50 Airplane; Function and Reliability Testing

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-18

    ... airplanes. 1. Function and Reliability Testing. Flight tests: In place of 14 CFR 21.35(b)(2), the following...; Function and Reliability Testing AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Final special... to CAR part 3 became effective January 15, 1951, and deleted the service test requirements in Section...

  14. Feasibility and Reliability of Physical Fitness Tests in Older Adults with Intellectual Disability: A Pilot Study

    ERIC Educational Resources Information Center

    Hilgenkamp, Thessa I. M.; van Wijck, Ruud; Evenhuis, Heleen M.

    2012-01-01

    Background: Physical fitness is relevant for wellbeing and health, but knowledge on the feasibility and reliability of instruments to measure physical fitness for older adults with intellectual disability is lacking. Methods: Feasibility and test-retest reliability of a physical fitness test battery (Box and Block Test, Response Time Test, walking…

  15. 75 FR 29962 - Special Conditions: Cirrus Design Corporation Model SF50 Airplane; Function and Reliability Testing

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-28

    ... SF50 airplanes. 1. Function and Reliability Testing Flight tests: In place of 14 CFR part 21.35(b)(2... Reliability Testing AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice of proposed special..., 1951, and deleted the service test requirements in Section 3.19 for airplanes of 6,000 pounds maximum...

  16. Verification techniques for x-ray and mammography applications

    NASA Astrophysics Data System (ADS)

    Kotsopoulos, Stavros A.; Lymberopoulos, Dimitris C.

    1993-07-01

    The integration of Medical Information Environment demands the study and development of high speed data communication systems with special designed 'endsystems' (MWS, etc.) for flexible and reliable data transmission/reception, handling and manipulation. An important parameter which affects the overall system's performance is the 'quality factor' of the communicated medical data produced by a wide range of modern modalities. The present paper describes a set of tests, done in a medical communication network based on a teleworking platform, in order to optimize the sensitivity parameters of the modalities by remote fine re-adjustments guided by experts.

  17. Reliability of physical functioning tests in patients with low back pain: a systematic review.

    PubMed

    Denteneer, Lenie; Van Daele, Ulrike; Truijen, Steven; De Hertogh, Willem; Meirte, Jill; Stassijns, Gaetane

    2018-01-01

    The aim of this study was to provide a comprehensive overview of physical functioning tests in patients with low back pain (LBP) and to investigate their reliability. A systematic computerized search was finalized in four different databases on June 24, 2017: PubMed, Web of Science, Embase, and MEDLINE. Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines were followed during all stages of this review. Clinical studies that investigate the reliability of physical functioning tests in patients with LBP were eligible. The methodological quality of the included studies was assessed with the use of the Consensus-based Standards for the selection of health Measurement Instruments (COSMIN) checklist. To come to final conclusions on the reliability of the identified clinical tests, the current review assessed three factors, namely, outcome assessment, methodological quality, and consistency of description. A total of 20 studies were found eligible and 38 clinical tests were identified. Good overall test-retest reliability was concluded for the extensor endurance test (intraclass correlation coefficient [ICC]=0.93-0.97), the flexor endurance test (ICC=0.90-0.97), the 5-minute walking test (ICC=0.89-0.99), the 50-ft walking test (ICC=0.76-0.96), the shuttle walk test (ICC=0.92-0.99), the sit-to-stand test (ICC=0.91-0.99), and the loaded forward reach test (ICC=0.74-0.98). For inter-rater reliability, only one test, namely, the Biering-Sörensen test (ICC=0.88-0.99), could be concluded to have an overall good inter-rater reliability. None of the identified clinical tests could be concluded to have a good intrarater reliability. Further investigation should focus on a better overall study methodology and the use of identical protocols for the description of clinical tests. The assessment of reliability is only a first step in the recommendation process for the use of clinical tests. In future research, the identified clinical tests in the current review should be further investigated for validity. Only when these clinimetric properties of a clinical test have been thoroughly investigated can a final conclusion regarding the clinical and scientific use of the identified tests be made. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. A comparison of the reliability of make versus break testing in measuring palmar abduction strength of the thumb.

    PubMed

    Lim, J X; Toh, R X; Chook, S K H; Sebastin, S J; Karjalainen, T

    2014-06-01

    Previous studies have established the role of quantitative measurements of palmar abduction strength of the thumb (PAST). This study compares the reliability of the 'make' versus the 'break' test in measuring PAST in healthy volunteers. In a 'make' test, the body part being tested is positioned at the start of its range of motion and the participant is asked to exert his/her maximal force. In a 'break' test, increasing force is applied to a body part after it has completed its range of motion, until the joint being tested gives way. PAST was measured in both hands in 100 healthy volunteers using a handheld device. Two examiners measured PAST using both the 'make' and 'break' test to determine inter-rater reliability. The tests were repeated in 30 volunteers 6 weeks after the initial testing to determine intra-rater reliability. Our results showed that the 'make' test has better inter and intra-rater reliability.

  19. Test effectiveness study report: An analytical study of system test effectiveness and reliability growth of three commercial spacecraft programs

    NASA Technical Reports Server (NTRS)

    Feldstein, J. F.

    1977-01-01

    Failure data from 16 commercial spacecraft were analyzed to evaluate failure trends, reliability growth, and effectiveness of tests. It was shown that the test programs were highly effective in ensuring a high level of in-orbit reliability. There was only a single catastrophic problem in 44 years of in-orbit operation on 12 spacecraft. The results also indicate that in-orbit failure rates are highly correlated with unit and systems test failure rates. The data suggest that test effectiveness estimates can be used to guide the content of a test program to ensure that in-orbit reliability goals are achieved.

  20. The replacement of dry heat in generic reliability assurance requirements for passive optical components

    NASA Astrophysics Data System (ADS)

    Ren, Xusheng; Qian, Longsheng; Zhang, Guiyan

    2005-12-01

    According to Generic Reliability Assurance Requirements for Passive Optical Components GR-1221-CORE (Issue 2, January 1999), reliability determination test of different kinds of passive optical components which using in uncontrolled environments is taken. The test condition of High Temperature Storage Test (Dry Test) and Damp Test is in below sheet. Except for humidity condition, all is same. In order to save test time and cost, after a sires of contrast tests, the replacement of Dry Heat is discussed. Controlling the Failure mechanism of dry heat and damp heat of passive optical components, the contrast test of dry heat and damp heat for passive optical components (include DWDM, CWDM, Coupler, Isolator, mini Isolator) is taken. The test result of isolator is listed. Telcordia test not only test the reliability of the passive optical components, but also test the patience of the experimenter. The cost of Telcordia test in money, manpower and material resources, especially in time is heavy burden for the company. After a series of tests, we can find that Damp heat could factually test the reliability of passive optical components, and equipment manufacturer in accord with component manufacture could omit the dry heat test if damp heat test is taken first and passed.

  1. Cultural adaptation and validation of the Health Literacy Questionnaire (HLQ): robust nine-dimension Danish language confirmatory factor model.

    PubMed

    Maindal, Helle Terkildsen; Kayser, Lars; Norgaard, Ole; Bo, Anne; Elsworth, Gerald R; Osborne, Richard H

    2016-01-01

    Health literacy is an important construct in population health and healthcare requiring rigorous measurement. The Health Literacy Questionnaire (HLQ), with nine scales, measures a broad perception of health literacy. This study aimed to adapt the HLQ to the Danish setting, and to examine the factor structure, homogeneity, reliability and discriminant validity. The HLQ was adapted using forward-backward translation, consensus conference and cognitive interviews (n = 15). Psychometric properties were examined based on data collected by face-to-face interview (n = 481). Tests included difficulty level, composite scale reliability and confirmatory factor analysis (CFA). Cognitive testing revealed that only minor re-wording was required. The easiest scale to respond to positively was 'Social support for health', and the hardest were 'Navigating the healthcare system' and 'Appraisal of health information'. CFA of the individual scales showed acceptably high loadings (range 0.49-0.93). CFA fit statistics after including correlated residuals were good for seven scales, acceptable for one. Composite reliability and Cronbach's α were >0.8 for all but one scale. A nine-factor CFA model was fitted to items with no cross-loadings or correlated residuals allowed. Given this restricted model, the fit was satisfactory. The HLQ appears robust for its intended application of assessing health literacy in a range of settings. Further work is required to demonstrate sensitivity to measure changes.

  2. Analytical Validation of the ReEBOV Antigen Rapid Test for Point-of-Care Diagnosis of Ebola Virus Infection

    PubMed Central

    Cross, Robert W.; Boisen, Matthew L.; Millett, Molly M.; Nelson, Diana S.; Oottamasathien, Darin; Hartnett, Jessica N.; Jones, Abigal B.; Goba, Augustine; Momoh, Mambu; Fullah, Mohamed; Bornholdt, Zachary A.; Fusco, Marnie L.; Abelson, Dafna M.; Oda, Shunichiro; Brown, Bethany L.; Pham, Ha; Rowland, Megan M.; Agans, Krystle N.; Geisbert, Joan B.; Heinrich, Megan L.; Kulakosky, Peter C.; Shaffer, Jeffrey G.; Schieffelin, John S.; Kargbo, Brima; Gbetuwa, Momoh; Gevao, Sahr M.; Wilson, Russell B.; Saphire, Erica Ollmann; Pitts, Kelly R.; Khan, Sheik Humarr; Grant, Donald S.; Geisbert, Thomas W.; Branco, Luis M.; Garry, Robert F.

    2016-01-01

    Background. Ebola virus disease (EVD) is a severe viral illness caused by Ebola virus (EBOV). The 2013–2016 EVD outbreak in West Africa is the largest recorded, with >11 000 deaths. Development of the ReEBOV Antigen Rapid Test (ReEBOV RDT) was expedited to provide a point-of-care test for suspected EVD cases. Methods. Recombinant EBOV viral protein 40 antigen was used to derive polyclonal antibodies for RDT and enzyme-linked immunosorbent assay development. ReEBOV RDT limits of detection (LOD), specificity, and interference were analytically validated on the basis of Food and Drug Administration (FDA) guidance. Results. The ReEBOV RDT specificity estimate was 95% for donor serum panels and 97% for donor whole-blood specimens. The RDT demonstrated sensitivity to 3 species of Ebolavirus (Zaire ebolavirus, Sudan ebolavirus, and Bundibugyo ebolavirus) associated with human disease, with no cross-reactivity by pathogens associated with non-EBOV febrile illness, including malaria parasites. Interference testing exhibited no reactivity by medications in common use. The LOD for antigen was 4.7 ng/test in serum and 9.4 ng/test in whole blood. Quantitative reverse transcription–polymerase chain reaction testing of nonhuman primate samples determined the range to be equivalent to 3.0 × 105–9.0 × 108 genomes/mL. Conclusions. The analytical validation presented here contributed to the ReEBOV RDT being the first antigen-based assay to receive FDA and World Health Organization emergency use authorization for this EVD outbreak, in February 2015. PMID:27587634

  3. Adaptable Holders for Arc-Jet Screening Candidate Thermal Protection System Repair Materials

    NASA Technical Reports Server (NTRS)

    Riccio, Joe; Milhoan, Jim D.

    2010-01-01

    Reusable holders have been devised for evaluating high-temperature, plasma-resistant re-entry materials, especially fabrics. Typical material samples tested support thermal-protection-system damage repair requiring evaluation prior to re-entry into terrestrial atmosphere. These tests allow evaluation of each material to withstand the most severe predicted re-entry conditions.

  4. Cross-cultural adaptation and validation of als Functional Rating Scale-Revised in Portuguese language.

    PubMed

    Guedes, Keyte; Pereira, Cecília; Pavan, Karina; Valério, Berenice Cataldo Oliveira

    2010-02-01

    The aim of this study is the cross-cultural, as well as to validate in Portuguese language the Amyotrophic Lateral Sclerosis Functional Rating Scale - Revised (ALSFRS-R). We performed a prospective study of individuals with amyotrophic lateral sclerosis (ALS) clinically defined. The scale, after obtaining the final version in Portuguese, was administered in 22 individuals and three weeks after re-applied. There were no significant differences between the application and reapplication of the scale (p=0.069). The linear regression and internal consistency measured by Pearson correlation and alpha Conbrach were significant with r=0.975 e alpha=0.934. The reliability test-retest demonstrated by intraclass correlation coefficient was strong with ICC=0.975. Therefore, this version proved to be applicable, reliable and easy to be conducted in clinical practice and research.

  5. Several submaximal exercise tests are reliable, valid and acceptable in people with chronic pain, fibromyalgia or chronic fatigue: a systematic review.

    PubMed

    Ratter, Julia; Radlinger, Lorenz; Lucas, Cees

    2014-09-01

    Are submaximal and maximal exercise tests reliable, valid and acceptable in people with chronic pain, fibromyalgia and fatigue disorders? Systematic review of studies of the psychometric properties of exercise tests. People older than 18 years with chronic pain, fibromyalgia and chronic fatigue disorders. Studies of the measurement properties of tests of physical capacity in people with chronic pain, fibromyalgia or chronic fatigue disorders were included. Studies were required to report: reliability coefficients (intraclass correlation coefficient, alpha reliability coefficient, limits of agreements and Bland-Altman plots); validity coefficients (intraclass correlation coefficient, Spearman's correlation, Kendal T coefficient, Pearson's correlation); or dropout rates. Fourteen studies were eligible: none had low risk of bias, 10 had unclear risk of bias and four had high risk of bias. The included studies evaluated: Åstrand test; modified Åstrand test; Lean body mass-based Åstrand test; submaximal bicycle ergometer test following another protocol other than Åstrand test; 2-km walk test; 5-minute, 6-minute and 10-minute walk tests; shuttle walk test; and modified symptom-limited Bruce treadmill test. None of the studies assessed maximal exercise tests. Where they had been tested, reliability and validity were generally high. Dropout rates were generally acceptable. The 2-km walk test was not recommended in fibromyalgia. Moderate evidence was found for reliability, validity and acceptability of submaximal exercise tests in patients with chronic pain, fibromyalgia or chronic fatigue. There is no evidence about maximal exercise tests in patients with chronic pain, fibromyalgia and chronic fatigue. Copyright © 2014. Published by Elsevier B.V.

  6. An exploratory study into the effect of time-restricted internet access on face-validity, construct validity and reliability of postgraduate knowledge progress testing

    PubMed Central

    2013-01-01

    Background Yearly formative knowledge testing (also known as progress testing) was shown to have a limited construct-validity and reliability in postgraduate medical education. One way to improve construct-validity and reliability is to improve the authenticity of a test. As easily accessible internet has become inseparably linked to daily clinical practice, we hypothesized that allowing internet access for a limited amount of time during the progress test would improve the perception of authenticity (face-validity) of the test, which would in turn improve the construct-validity and reliability of postgraduate progress testing. Methods Postgraduate trainees taking the yearly knowledge progress test were asked to participate in a study where they could access the internet for 30 minutes at the end of a traditional pen and paper test. Before and after the test they were asked to complete a short questionnaire regarding the face-validity of the test. Results Mean test scores increased significantly for all training years. Trainees indicated that the face-validity of the test improved with internet access and that they would like to continue to have internet access during future testing. Internet access did not improve the construct-validity or reliability of the test. Conclusion Improving the face-validity of postgraduate progress testing, by adding the possibility to search the internet for a limited amount of time, positively influences test performance and face-validity. However, it did not change the reliability or the construct-validity of the test. PMID:24195696

  7. [Internal consistency and criterion validity and reliability of the Mexican Version of the Child Behavior Checklist 1.5-5 (CBCL/1.5-5)].

    PubMed

    Albores-Gallo, Lilia; Hernández-Guzmán, Laura; Hasfura-Buenaga, Cecilia; Navarro-Luna, Enrique

    To investigate the validity and internal consistency of the Mexican version of the CBCL/1.5 -5 that assesses the most common psychopathology in pre-school children in clinical and epidemiological settings. A total of 438 parents from two groups, clinical-psychiatric (N= 62) and community (N= 376) completed the CBCL/1.5-5/Mexican version. The internal consistency was high for total problems α=0.95, and internalized α=0.89 and externalized α=0.91 subscales. The test re-test (one week) using the intraclass correlation coefficient (ICC) was ≥ 0.95 for the internalized, externalized, and total problems subscales. The ROC curve for the criterion status of clinically-referred vs. non-referred using the total problems scale ≥ 24 resulted in an AUC (area under curve) of 0.77, a specificity 0.73, and a sensitivity of 0.70. The CBCL/1.5 -5/Mexican version is a reliable and valid tool. Copyright © 2016 Sociedad Chilena de Pediatría. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. Inter-Observer, Intra-Observer and Intra-Individual Reliability of Uroflowmetry Tests in Aged Men: A Generalizability Theory Approach.

    PubMed

    Liu, Ying-Buh; Yang, Stephen S; Hsieh, Cheng-Hsing; Lin, Chia-Da; Chang, Shang-Jen

    2014-05-01

    To evaluate the inter-observer, intra-observer and intra-individual reliability of uroflowmetry and post-void residual urine (PVR) tests in adult men. Healthy volunteers aged over 40 years were enrolled. Every participant underwent two sets of uroflowmetry and PVR tests with a 2-week interval between the tests. The uroflowmetry tests were interpreted by four urologists independently. Uroflowmetry curves were classified as bell-shaped, bell-shaped with tail, obstructive, restrictive, staccato, interrupted and tower-shaped and scored from 1 (highly abnormal) to 5 (absolutely normal). The agreements between the observers, interpretations and tests within individuals were analyzed using kappa statistics and intraclass correlation coefficients. Generalizability theory with decision analysis was used to determine how many observers, tests, and interpretations were needed to obtain an acceptable reliability (> 0.80). Of 108 volunteers, we randomly selected the uroflowmetry results from 25 participants for the evaluation of reliability. The mean age of the studied adults was 55.3 years. The intra-individual and intra-observer reliability on uroflowmetry tests ranged from good to very good. However, the inter-observer reliability on normalcy and specific type of flow pattern were relatively lower. In generalizability theory, three observers were needed to obtain an acceptable reliability on normalcy of uroflow pattern if the patient underwent uroflowmetry tests twice with one observation. The intra-individual and intra-observer reliability on uroflowmetry tests were good while the inter-observer reliability was relatively lower. To improve inter-observer reliability, the definition of uroflowmetry should be clarified by the International Continence Society. © 2013 Wiley Publishing Asia Pty Ltd.

  9. Data re-arranging techniques leading to proper variable selections in high energy physics

    NASA Astrophysics Data System (ADS)

    Kůs, Václav; Bouř, Petr

    2017-12-01

    We introduce a new data based approach to homogeneity testing and variable selection carried out in high energy physics experiments, where one of the basic tasks is to test the homogeneity of weighted samples, mainly the Monte Carlo simulations (weighted) and real data measurements (unweighted). This technique is called ’data re-arranging’ and it enables variable selection performed by means of the classical statistical homogeneity tests such as Kolmogorov-Smirnov, Anderson-Darling, or Pearson’s chi-square divergence test. P-values of our variants of homogeneity tests are investigated and the empirical verification through 46 dimensional high energy particle physics data sets is accomplished under newly proposed (equiprobable) quantile binning. Particularly, the procedure of homogeneity testing is applied to re-arranged Monte Carlo samples and real DATA sets measured at the particle accelerator Tevatron in Fermilab at DØ experiment originating from top-antitop quark pair production in two decay channels (electron, muon) with 2, 3, or 4+ jets detected. Finally, the variable selections in the electron and muon channels induced by the re-arranging procedure for homogeneity testing are provided for Tevatron top-antitop quark data sets.

  10. Testing for PV Reliability (Presentation)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kurtz, S.; Bansal, S.

    The DOE SUNSHOT workshop is seeking input from the community about PV reliability and how the DOE might address gaps in understanding. This presentation describes the types of testing that are needed for PV reliability and introduces a discussion to identify gaps in our understanding of PV reliability testing.

  11. Development and pilot testing of an online module for ethics education based on the Nigerian National Code for Health Research Ethics.

    PubMed

    Ogunrin, Olubunmi A; Ogundiran, Temidayo O; Adebamowo, Clement

    2013-01-02

    The formulation and implementation of national ethical regulations to protect research participants is fundamental to ethical conduct of research. Ethics education and capacity are inadequate in developing African countries. This study was designed to develop a module for online training in research ethics based on the Nigerian National Code of Health Research Ethics and assess its ease of use and reliability among biomedical researchers in Nigeria. This was a three-phased evaluation study. Phase one involved development of an online training module based on the Nigerian Code of Health Research Ethics (NCHRE) and uploading it to the Collaborative Institutional Training Initiative (CITI) website while the second phase entailed the evaluation of the module for comprehensibility, readability and ease of use by 45 Nigerian biomedical researchers. The third phase involved modification and re-evaluation of the module by 30 Nigerian biomedical researchers and determination of test-retest reliability of the module using Cronbach's alpha. The online module was easily accessible and comprehensible to 95% of study participants. There were significant differences in the pretest and posttest scores of study participants during the evaluation of the online module (p = 0.001) with correlation coefficients of 0.9 and 0.8 for the pretest and posttest scores respectively. The module also demonstrated excellent test-retest reliability and internal consistency as shown by Cronbach's alpha coefficients of 0.92 and 0.84 for the pretest and posttest respectively. The module based on the Nigerian Code was developed, tested and made available online as a valuable tool for training in cultural and societal relevant ethical principles to orient national and international biomedical researchers working in Nigeria. It would complement other general research ethics and Good Clinical Practice modules. Participants suggested that awareness of the online module should be increased through seminars, advertisement on government websites and portals used by Nigerian biomedical researchers, and incorporation of the Code into the undergraduate medical training curriculum.

  12. A study of visual and blood contamination on reprocessed endodontic files from general dental practice.

    PubMed

    Letters, S; Smith, A J; McHugh, S; Bagg, J

    2005-10-22

    This study examined methods used for reprocessing endodontic instruments in general dental practice and determined the degree of residual visual contamination and blood contamination on 250 reprocessed files collected from 25 general dental practices. A questionnaire was administered to 25 general dental practitioners to obtain information on the re-processing of used endodontic files. Ten files which had been used and reprocessed were also collected from each practice. These were examined visually under a dissecting light microscope for residual contamination and then tested for blood deposits using the Kastle-Meyer test. Nineteen of the 25 practices used stainless steel hand files. No practitioners used endodontic files as single use devices. Ninety-two per cent of the practitioners discarded and replaced files when they were bent or damaged. Several decontamination methods were reported. The two combinations employed most frequently were manual cleaning and autoclaving or manual cleaning, followed by ultrasonic cleaning and autoclaving. Of the 250 files, 75% showed some degree of visual contamination and seven percent tested positive for residual blood. Blood contaminated files were significantly more heavily contaminated when examined visually. Large variations were found in residual contamination of files collected from practices using the same methods of decontamination. While all practitioners re-used endodontic files, the variations in decontamination methods reported indicate a lack of clarity on best practice. This study demonstrates that endodontic files are not reliably decontaminated by methods currently employed in dental practice.

  13. Reliability of fitness tests using methods and time periods common in sport and occupational management.

    PubMed

    Burnstein, Bryan D; Steele, Russell J; Shrier, Ian

    2011-01-01

    Fitness testing is used frequently in many areas of physical activity, but the reliability of these measurements under real-world, practical conditions is unknown. To evaluate the reliability of specific fitness tests using the methods and time periods used in the context of real-world sport and occupational management. Cohort study. Eighteen different Cirque du Soleil shows. Cirque du Soleil physical performers who completed 4 consecutive tests (6-month intervals) and were free of injury or illness at each session (n = 238 of 701 physical performers). Performers completed 6 fitness tests on each assessment date: dynamic balance, Harvard step test, handgrip, vertical jump, pull-ups, and 60-second jump test. We calculated the intraclass coefficient (ICC) and limits of agreement between baseline and each time point and the ICC over all 4 time points combined. Reliability was acceptable (ICC > 0.6) over an 18-month time period for all pairwise comparisons and all time points together for the handgrip, vertical jump, and pull-up assessments. The Harvard step test and 60-second jump test had poor reliability (ICC < 0.6) between baseline and other time points. When we excluded the baseline data and calculated the ICC for 6-month, 12-month, and 18-month time points, both the Harvard step test and 60-second jump test demonstrated acceptable reliability. Dynamic balance was unreliable in all contexts. Limit-of-agreement analysis demonstrated considerable intraindividual variability for some tests and a learning effect by administrators on others. Five of the 6 tests in this battery had acceptable reliability over an 18-month time frame, but the values for certain individuals may vary considerably from time to time for some tests. Specific tests may require a learning period for administrators.

  14. Tube and column agglutination technology for autocontrol testing.

    PubMed

    Courtney, J E; Vincent, J L; Indrikovs, A J

    2001-01-01

    The incidence of positive autocontrol test results with column agglutination technology is a concern. This study investigates the incidence and significance of positive autocontrols in the ID Micro Typing System (gel) and the Gamma ReACT (ReACT). The study encompassed a total of 1021 randomly selected samples from patients and 95 samples from donors collected during 1 month. The autocontrol testing was carried out according to the manufacturer's instructions for the column agglutination tests. The tube method was carried out using low-ionic-strength solution (LISS). The direct antiglobulin test (DAT) was performed using the tube method, and further investigated with elution studies if warranted. Seventy-nine patient's samples (7.74%) had a positive autocontrol: the gel test, 72 (91.13%); ReACT, 21 (26.58%); and the tube method, 27 (34.18%). Of the 79 positive autocontrols, 44 samples had a negative DAT. Of the samples with positive DAT results, only one possessed a clinically significant antibody, anti-D. Moreover, the same sample also tested positive in all three methods. Column agglutination techniques have increased sensitivity for a positive autocontrol beyond the conventional tube method. However, ReACT and gel tests differ significantly in their frequency of positives. Investigation of the significance of a positive autocontrol in column agglutination technology when the conventional tube method is also positive is suggested.

  15. An alternative to the balance error scoring system: using a low-cost balance board to improve the validity/reliability of sports-related concussion balance testing.

    PubMed

    Chang, Jasper O; Levy, Susan S; Seay, Seth W; Goble, Daniel J

    2014-05-01

    Recent guidelines advocate sports medicine professionals to use balance tests to assess sensorimotor status in the management of concussions. The present study sought to determine whether a low-cost balance board could provide a valid, reliable, and objective means of performing this balance testing. Criterion validity testing relative to a gold standard and 7 day test-retest reliability. University biomechanics laboratory. Thirty healthy young adults. Balance ability was assessed on 2 days separated by 1 week using (1) a gold standard measure (ie, scientific grade force plate), (2) a low-cost Nintendo Wii Balance Board (WBB), and (3) the Balance Error Scoring System (BESS). Validity of the WBB center of pressure path length and BESS scores were determined relative to the force plate data. Test-retest reliability was established based on intraclass correlation coefficients. Composite scores for the WBB had excellent validity (r = 0.99) and test-retest reliability (R = 0.88). Both the validity (r = 0.10-0.52) and test-retest reliability (r = 0.61-0.78) were lower for the BESS. These findings demonstrate that a low-cost balance board can provide improved balance testing accuracy/reliability compared with the BESS. This approach provides a potentially more valid/reliable, yet affordable, means of assessing sports-related concussion compared with current methods.

  16. Arthroscopic Diagnosis of the Triangular Fibrocartilage Complex Foveal Tear: A Cadaver Assessment.

    PubMed

    Trehan, Samir K; Wall, Lindley B; Calfee, Ryan P; Shen, Tony S; Dy, Christopher J; Yannascoli, Sarah M; Goldfarb, Charles A

    2018-01-25

    To determine whether the arthroscopic hook and trampoline tests are accurate and reliable diagnostic tests for foveal triangular fibrocartilage complex (TFCC) detachment. Wrist arthroscopy was performed on 10 cadaveric upper extremities. Arthroscopic hook and trampoline tests were performed and videos recorded (baseline). The deep foveal TFCC insertion was then sharply detached. Arthroscopic hook and trampoline tests were repeated. Subsequently, the foveal detachment was repaired via an ulnar tunnel technique and the hook test was repeated for a third time. Videos were independently reviewed at 2 time points by 2 fellowship-trained hand surgeons and 1 hand surgery fellow in a randomized and blinded fashion. Hook and trampoline tests were graded as positive or negative. Proportions of categorical variables were compared via 2-tailed Fisher exact test. Inter- and intraobserver reliabilities were assessed via Cohen kappa coefficient. The sensitivity and specificity of the hook test for foveal detachment diagnosis were 90% and 90%, respectively. There was 90% agreement among all 3 observers for the baseline and foveal detachment hook tests. Cohen kappa coefficients for the inter- and intraobserver reliabilities of the hook test were 0.87 and 0.81, respectively. Seventeen percent of trampoline tests were positive at baseline versus 43% after foveal detachment. The trampoline test had 45% agreement between the 3 observers. Cohen kappa coefficients for the inter- and intraobserver reliabilities of the trampoline test were 0.16 and 0.63, respectively. Following ulnar tunnel repair, 20% of hook tests were positive. The hook test is highly sensitive, specific, and reliable for the diagnosis of isolated TFCC foveal detachment. The trampoline test has insufficient reliability to assess foveal detachment. A TFCC foveal repair using an ulnar tunnel technique returns the hook test to baseline. The hook test is a sensitive, specific, and reliable test for the diagnosis of isolated TFCC foveal detachment. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  17. Interexaminer reliability in physical examination of patients with low back pain.

    PubMed

    Strender, L E; Sjöblom, A; Sundell, K; Ludwig, R; Taube, A

    1997-04-01

    Seventy-one patients with low back pain were examined by two physiotherapists (50 patients) and two physicians (21 patients). The two physiotherapists had worked together for many years, but the two physicians had not. The interexaminer reliability of the clinical tests included in the physical examination was evaluated. To evaluate the interexaminer reliability of clinical tests used in the physical examination of patients with low back pain under ideal circumstances, which was the case for the physiotherapists. Numerous clinical tests are used in the evaluation of patients with low back pain. To reach the correct diagnosis, only tests with an acceptable validity and reliability should be used. Previous studies have mainly shown low reliability. It is important that clinical tests not be rejected because of low reliability caused by differences between examiners in performance of the examination and in their definition of normal results. Two examiners, either two physiotherapists or two physicians, independently examined patients with low back pain. In approximately half of the clinical tests studied, an acceptable reliability was demonstrated. On the basis of the physiotherapists series, the reliability was acceptable for a number of clinical tests that are used in the evaluation of patients with low back pain. The results suggest that clinical tests should be standardized to a much higher degree than they are today.

  18. Reliability of the Fox-walk test in patients with rheumatoid arthritis.

    PubMed

    Verberkt, Cornelia Antonia; Fridén, Cecilia; Grooten, Wilhelmus Johannes Andreas; Opava, Christina H

    2012-01-01

    The Fox-walk test is a new method used to estimate aerobic capacity outside a clinical environment, which may be useful in the implementation of daily health-enhancing physical activity. The aim of our study was to investigate the reliability of the test in people with rheumatoid arthritis (RA). Fifteen participants performed the Fox-walk test three times with weekly intervals. The intraclass correlation coefficient (ICC), the standard error of measurement (SEM) and the smallest detectable change (SDC) were used to estimate the reliability. General health perception, lower limb pain and fatigue were measured to determine their potential influence on the reliability. There were no systematic differences between the three test occasions (p = 0.190) and the reliability was almost perfect (ICC = 0.982). None of the covariates influenced the reliability. The SEM was 0.999 ml/kg/min or 3.4% and the SDC was 2.769 ml/kg/min or 9.4%. These findings demonstrate that the Fox-walk test is reliable in people with RA and enables differentiation between people with RA and monitoring progress. The validity of the test among people with RA is still to be determined. • The Fox-walk test is a new method to estimate aerobic capacity and could be performed walking or running. • The test is self administered without expensive equipment and is available in 150 public places in Sweden and several other European countries. • The Fox-walk test is a reliable test for use among people with rheumatoid arthritis monitoring the progress of their physical activity.

  19. Reliability and Validation of the International Consultation on Incontinence Questionnaire in Over Active Bladder to Persian Language.

    PubMed

    Sari Motlagh, Reza; Hajebrahimi, Sakineh; Sadeghi-Bazargani, Homayoun; Joodi Tutunsaz, Javad

    2015-05-01

    Overactive bladder syndrome is a common syndrome in the world in both men and women. Correct diagnosis and accurate measurement of symptoms severity and also quality of life of patients is necessary to ensure proper treatment and to facilitate sound relationships among patients, researchers and doctors. The International Consultation on Incontinence Questionnaire in Over Active Bladder (ICIQ-OAB) questionnaire is a concise and strong tool to evaluate the symptoms of OAB and their effects on patients' quality of life and treatment results. The objective of this study was to translate and validate a simple and strong tool that could be used in clinics and research. First, the original British English questionnaire was translated into Persian by two bilingual and originally Persian-speaking translators. Then the Persian version was back translated to English and a native English speaker studied and compared the questionnaire with the original version. At the end, the translated and corrected Persian version was finalized by a research team. Content validity of the items and ensuring that the questions could convey the main concept to readers was assessed through Modified Content Validity Index (MCVI). Reliability was calculated by Cronbach's α coefficient. Internal Consistency of the questionnaire with the calculation of Kendall correlation coefficient were evaluated by performing test-retest in 50 participants. The modified content validity index was > 0.78 for all of the questions. Cronbach's α coefficient was calculated 0.76 for all of the participants. Kendall correlation coefficient was calculated for test-re-test assessment 0.66. Both of which indicates the reliability of this questionnaire. Persian version of ICIQ-OAB questionnaire is a simple and strong tool for research, treatment and screening purposes. © 2014 Wiley Publishing Asia Pty Ltd.

  20. A study of reusable electromechanical impedance methods for structural health monitoring of civil structures

    NASA Astrophysics Data System (ADS)

    Tawie, R.; Na, S.; Lee, H. K.

    2013-04-01

    Up to date, various studies have been conducted using electro-mechanical impedance (EMI) method on concrete, including monitoring the strength development or to find damage in the structure. Since EMI method utilizes a single piezoelectric material to be used as an actuator and a sensor simultaneously, the method has major advantages compared to other non-destructive testing methods. However the method requires a piezoelectric material to be permanently attached or embedded into a structure. Thus when monitoring multiple structures, the method may become quite expensive. In this study, two re-usable EMI methods conducted by researchers Na et al and Tawie et al are overviewed. The idea of re-usable EMI method is still relatively new, resulting in the reduction of monitoring costs since the same piezoelectric material is used as many times as possible, while ensuring better repeatability and reliability in measurements.

  1. Reliability and validity of an arabic version of the dyspnea-12 questionnaire for Saudi nationals with chronic obstructive pulmonary disease.

    PubMed

    Alyami, Mohammed M; Jenkins, Sue C; Lababidi, Hani; Hill, Kylie

    2015-01-01

    Dyspnea is a distressing symptom experienced by people with chronic obstructive pulmonary disease (COPD). The dyspnea-12 (D-12) questionnaire comprises of 12 items and assesses the quality of this symptom, its severity and the emotional response. The original (English) version of the D-12 is reliable and valid for the measurement of dyspnea in pulmonary diseases. To translate the D-12 into Arabic and determine whether this version is reliable and valid in Saudi nationals with COPD. The D-12 was translated into Arabic version and reviewed by an expert panel before being back-translated into English. The Arabic version was administered to five patients with COPD to test whether it was easily understood after which a final Arabic version was produced. Thereafter, 40 patients with COPD (aged 63 ΁ 9 years; 33 [82.5%] males; forced expiratory volume in one second (FEV 1) 47 ΁ 16% predicted) completed the D-12, the COPD Assessment Test (CAT) and the Chronic Respiratory Disease Questionnaire (CRDQ). Lung function and 6-minute walk distance were also measured. The D-12 was re-administered two weeks later. The Arabic version of the D-12 demonstrated good reliability over the two administration (intraclass correlation coefficient = 0.94, P = 0.01). Strong associations were demonstrated between the (1) total score for the D-12 and the CAT, (2) quality sub-score of the D-12 and the CAT and (3) emotional response sub-score of the D-12 and emotional function domain of the CRDQ (r ≥ 0.6, all P < 0.01). The Arabic version of the D-12 is a reliable and valid instrument in Saudi nationals with COPD.

  2. Patient Assessment of Constipation Quality of Life Questionnaire: Translation, Cultural Adaptation, Reliability, and Validity of the Persian Version.

    PubMed

    Nikjooy, Afsaneh; Jafari, Hassan; Saba, Maryam A; Ebrahimi, Naghmeh; Mirzaei, Rezvan

    2018-05-01

    The Patient Assessment of Constipation Quality of Life (PAC-QOL) questionnaire is the most validated and the most specific tool for measuring the quality of life of patients with constipation. Over 120 million people live in countries whose official language is Persian. There is no reported Persian version of the PAC-QOL questionnaire yet. The aim of this study was to translate and culturally adapt the PAC-QOL questionnaire and to assess its reliability and validity among Persian patients with chronic constipation. Following the translation and cultural adaptation of the PAC-QOL questionnaire to Persian, 100 patients (mean±SD age=40.51±13.67) with constipation were recruited for validity measurement and 20 patients were re-examined for reliability. Content validity was assessed based on the opinions of an expert committee and the floor/ceiling effect. Construct validity was evaluated according to the hypothesis test. The SF-36 questionnaire was used for concurrent criterion validity, intra-class correlation coefficient for reliability, and Cronbach's alpha for internal consistency. The content validity of the PAC-QOL questionnaire was proven, and there was no floor/ceiling effect. Construct validity also was confirmed based on the hypothesis test. The overall Cronbach's alpha of the PAC-QOL questionnaire was 0.92 (range=0.72-0.92), and the overall intra-class correlation coefficient of the questionnaire was 0.88 (range=0.69-0.87). The correlation between the SF-36 and PAC-QOL questionnaires was moderate. The Persian version of the PAC-QOL questionnaire demonstrated good validity and reliability properties in chronic constipation. Accordingly, Persian researchers and clinicians can benefit from this questionnaire in further research and assessment of treatment outcomes.

  3. Reliability of a functional test battery evaluating functionality, proprioception, and strength in recreational athletes with functional ankle instability.

    PubMed

    Sekir, U; Yildiz, Y; Hazneci, B; Ors, F; Saka, T; Aydin, T

    2008-12-01

    In contrast to the single evaluation methods used in the past, the combination of multiple tests allows one to obtain a global assessment of the ankle joint. The aim of this study was to determine the reliability of the different tests in a functional test battery. Twenty-four male recreational athletes with unilateral functional ankle instability (FAI) were recruited for this study. One component of the test battery included five different functional ability tests. These tests included a single limb hopping course, single-legged and triple-legged hop for distance, and six and cross six meter hop for time. The ankle joint position sense and one leg standing test were used for evaluation of proprioception and sensorimotor control. The isokinetic strengths of the ankle invertor and evertor muscles were evaluated at a velocity of 120 degrees /s. The reliability of the test battery was assessed by calculating the intraclass correlation coefficient (ICC). Each subject was tested two times, with an interval of 3-5 days between the test sessions. The ICCs for ankle functional and proprioceptive ability showed high reliability (ICCs ranging from 0.94 to 0.98). Additionally, isokinetic ankle joint inversion and eversion strength measurements represented good to high reliability (ICCs between 0.82 and 0.98). The functional test battery investigated in this study proved to be a reliable tool for the assessment of athletes with functional ankle instability. Therefore, clinicians may obtain reliable information from the functional test battery during the assessment of ankle joint performance in patients with functional ankle instability.

  4. Reliability and feasibility of the six minute walk test in subjects with myotonic dystrophy.

    PubMed

    Kierkegaard, Marie; Tollbäck, Anna

    2007-12-01

    The objective was to describe test-retest reliability and feasibility of the six minute walk test in adult subjects with myotonic dystrophy type 1. Twelve subjects (28-68 years, mean 44) performed three six minute walk tests on two occasions, one week apart. Relative reliability was high (ICC(2.1)=0.99) and absolute reliability values were low (standard error of measurement 12 m, repeatability 33 m). Feasibility was investigated in a sample of 64 subjects (19-70 years, mean 43). Fifty-two subjects were able to perform two tests on the same day. Subjects with severe proximal weakness had difficulties performing repeated tests. A practice trial followed by a second test on the same day can be recommended for most subjects, and the best test should be used for evaluations. In conclusion, even though the study sample was small, the present study indicates that the six minute walk test is reliable and feasible in subjects with myotonic dystrophy type 1.

  5. Comparison of the reliability of parental reporting and the direct test of the Thai Speech and Language Test.

    PubMed

    Prathanee, Benjamas; Angsupakorn, Nipa; Pumnum, Tawitree; Seepuaham, Cholada; Jaiyong, Pechcharat

    2012-11-01

    To find reliability of parental or caregiver's report and testing of the Thai Speech and Language Test for Children Aged 0-4 Years Old. Five investigators assessed speech and language abilities from video both contexts: parental or caregivers' report and test forms of Thai Speech and Language Test for Children Aged 0-4 Years Old. Twenty-five normal and 30 children with delayed development or risk for delayed speech and language skills were assessed at age intervals of 3, 6, 9, 12, 15, 18, 24, 30, 36 and 48 months. Reliability of parental or caregivers' testing and reporting was at a moderate level (0.41-0.60). Inter-rater reliability among investigators was excellent (0.86-1.00). The parental or caregivers' report form of the Thai Speech and Language test for Children aged 0-4 years old was an indicator for success at a moderate level. Trained professionals could use both forms of this test as reliable tools at an excellent level.

  6. Thermal Vacuum Facility for Testing Thermal Protection Systems

    NASA Technical Reports Server (NTRS)

    Daryabeigi, Kamran; Knutson, Jeffrey R.; Sikora, Joseph G.

    2002-01-01

    A thermal vacuum facility for testing launch vehicle thermal protection systems by subjecting them to transient thermal conditions simulating re-entry aerodynamic heating is described. Re-entry heating is simulated by controlling the test specimen surface temperature and the environmental pressure in the chamber. Design requirements for simulating re-entry conditions are briefly described. A description of the thermal vacuum facility, the quartz lamp array and the control system is provided. The facility was evaluated by subjecting an 18 by 36 in. Inconel honeycomb panel to a typical re-entry pressure and surface temperature profile. For most of the test duration, the average difference between the measured and desired pressures was 1.6% of reading with a standard deviation of +/- 7.4%, while the average difference between measured and desired temperatures was 7.6% of reading with a standard deviation of +/- 6.5%. The temperature non-uniformity across the panel was 12% during the initial heating phase (t less than 500 sec.), and less than 2% during the remainder of the test.

  7. HIFIRE Flight 2 Overview and Status Update 2011

    NASA Technical Reports Server (NTRS)

    Jackson, Kevin R.; Gruber, Mark R.; Buccellato, Salvatore

    2011-01-01

    A collaborative international effort, the Hypersonic International Flight Research Experimentation (HIFiRE) Program aims to study basic hypersonic phenomena through flight experimentation. HIFiRE Flight 2 teams the United States Air Force Research Lab (AFRL), NASA, and the Australian Defence Science and Technology Organisation (DSTO). Flight 2 will develop an alternative test technique for acquiring high enthalpy scramjet flight test data, allowing exploration of accelerating hydrocarbon-fueled scramjet performance and dual-to-scram mode transition up to and beyond Mach 8 flight. The generic scramjet flowpath is research quality and the test fuel is a simple surrogate for an endothermically cracked liquid hydrocarbon fuel. HIFiRE Flight 2 will be a first of its kind in contribution to scramjets. The HIFiRE program builds upon the HyShot and HYCAUSE programs and aims to leverage the low-cost flight test technique developed in those programs. It will explore suppressed trajectories of a sounding rocket propelled test article and their utility in studying ramjet-scramjet mode transition and flame extinction limits research. This paper describes the overall scramjet flight test experiment mission goals and objectives, flight test approach and strategy, ground test and analysis summary, development status and project schedule. A successful launch and operation will present to the scramjet community valuable flight test data in addition to a new tool, and vehicle, with which to explore high enthalpy scramjet technologies.

  8. Association between elder abuse and poor sleep: A cross-sectional study among rural older Malaysians

    PubMed Central

    Hairi, Noran N.; Choo, Wan Yuen; Hairi, Farizah M.; Sooryanarayana, Rajini; Ahmad, Sharifah N.; Razak, Inayah A.; Peramalah, Devi; Aziz, Suriyati A.; Mohamad, Zaiton L.; Mohamad, Rosmala; Ali, Zainudin M.; Awang Mahmud, Awang B.

    2017-01-01

    Objectives To examine the association between elder abuse and poor sleep using a Malay validated version of Pittsburgh Sleep Quality Index (PSQI). Design This study was divided into two phases. Phase I tested the construct validity and reliability of the Malay version of PSQI. Phase II was a population-based, cross-sectional study with a multi-stage cluster sampling method. Home-based interviews were conducted by trained personnel using a structured questionnaire, to determine exposure and outcome. Setting Kuala Pilah, a district in Negeri Sembilan which is one of the fourteen states in Malaysia. Participants 1648 community-dwelling older Malaysians. Results The Malay version of PSQI had significant test re-test reliability with intra-class correlation coefficients of 0.62. Confirmatory factor analyses revealed that one factor PSQI scale with three components (subjective sleep quality, sleep latency, and sleep disturbances) was most suitable. Cronbach’s Alpha was 0.60 and composite reliability was 0.63. PSQI scores were highest among neglect (4.11), followed by physical (4.10), psychological (3.96) and financial abuse (3.60). There was a dose-response relationship between clustering of abuse and PSQI scores; 3.41, 3.50 and 3.84 for “no abuse”, “1 type of abuse” and “2 types or more”. Generalized linear models revealed six variables as significant determinants of sleep quality–abuse, co-morbidities, self-rated health, income, social support and gait speed. Among abuse subtypes, only neglect was significantly associated with poor sleep. Conclusion The Malay PSQI was valid and reliable. Abuse was significantly associated with poor sleep. As sleep is essential for health and is a good predictor for mortality among older adults, management of abuse victims should entail sleep assessment. Interventions or treatment modalities which focus on improving sleep quality among abuse victims should be designed. PMID:28686603

  9. An Investigation of the Impact of Guessing on Coefficient α and Reliability

    PubMed Central

    2014-01-01

    Guessing is known to influence the test reliability of multiple-choice tests. Although there are many studies that have examined the impact of guessing, they used rather restrictive assumptions (e.g., parallel test assumptions, homogeneous inter-item correlations, homogeneous item difficulty, and homogeneous guessing levels across items) to evaluate the relation between guessing and test reliability. Based on the item response theory (IRT) framework, this study investigated the extent of the impact of guessing on reliability under more realistic conditions where item difficulty, item discrimination, and guessing levels actually vary across items with three different test lengths (TL). By accommodating multiple item characteristics simultaneously, this study also focused on examining interaction effects between guessing and other variables entered in the simulation to be more realistic. The simulation of the more realistic conditions and calculations of reliability and classical test theory (CTT) item statistics were facilitated by expressing CTT item statistics, coefficient α, and reliability in terms of IRT model parameters. In addition to the general negative impact of guessing on reliability, results showed interaction effects between TL and guessing and between guessing and test difficulty.

  10. Test-retest reliability of the Capute scales for neurodevelopmental screening of a high risk sample: Impact of test-retest interval and degree of neonatal risk.

    PubMed

    McCurdy, M; Bellows, A; Deng, D; Leppert, M; Mahone, E; Pritchard, A

    2015-01-01

    Reliable and valid screening and assessment tools are necessary to identify children at risk for neurodevelopmental disabilities who may require additional services. This study evaluated the test-retest reliability of the Capute Scales in a high-risk sample, hypothesizing adequate reliability across 6- and 12-month intervals. Capute Scales scores (N = 66) were collected via retrospective chart review from a NICU follow-up clinic within a large urban medical center spanning three age-ranges: 12-18, 19-24, and 25-36 months. On average, participants were classified as very low birth weight and premature. Reliability of the Capute Scales was evaluated with intraclass correlation coefficients across length of test-retest interval, age at testing, and degree of neonatal complications. The Capute Scales demonstrated high reliability, regardless of length of test-retest interval (ranging from 6 to 14 months) or age of participant, for all index scores, including overall Developmental Quotient (DQ), language-based skill index (CLAMS) and nonverbal reasoning index (CAT). Linear regressions revealed that greater neonatal risk was related to poorer test-retest reliability; however, reliability coefficients remained strong. The Capute Scales afford clinicians a reliable and valid means of screening and assessing for neurodevelopmental delay within high-risk infant populations.

  11. Test-Retest Reliability and Predictive Validity of the Implicit Association Test in Children

    ERIC Educational Resources Information Center

    Rae, James R.; Olson, Kristina R.

    2018-01-01

    The Implicit Association Test (IAT) is increasingly used in developmental research despite minimal evidence of whether children's IAT scores are reliable across time or predictive of behavior. When test-retest reliability and predictive validity have been assessed, the results have been mixed, and because these studies have differed on many…

  12. Reliability Analysis for the Internationally Administered 2002 Series GED Tests. GED Testing Service[R] Research Studies, 2009-3

    ERIC Educational Resources Information Center

    Setzer, J. Carl; He, Yi

    2009-01-01

    Reliability Analysis for the Internationally Administered 2002 Series GED (General Educational Development) Tests Reliability refers to the consistency, or stability, of test scores when the authors administer the measurement procedure repeatedly to groups of examinees (American Educational Research Association [AERA], American Psychological…

  13. An Integrated Approach to Establish Validity and Reliability of Reading Tests

    ERIC Educational Resources Information Center

    Razi, Salim

    2012-01-01

    This study presents the processes of developing and establishing reliability and validity of a reading test by administering an integrative approach as conventional reliability and validity measures superficially reveals the difficulty of a reading test. In this respect, analysing vocabulary frequency of the test is regarded as a more eligible way…

  14. A study of blood contamination of Siqveland matrix bands.

    PubMed

    Lowe, A H; Bagg, J; Burke, F J T; MacKenzie, D; McHugh, S

    2002-01-12

    AIMS To use a sensitive forensic test to measure blood contamination of used Siqveland matrix bands following routine cleaning and sterilisation procedures in general dental practice. Sixteen general dental practices in the West of Scotland participated. Details of instrument cleaning procedures were recorded for each practice. A total of 133 Siqveland matrix bands were recovered following cleaning and sterilisation and were examined for residual blood contamination by the Kastle-Meyer test, a well-recognised forensic technique. Ultrasonic baths were used for the cleaning of 62 (47%) bands and retainers and the remainder (53%) were hand scrubbed prior to autoclaving. Overall, 21% of the matrix bands and 19% of the retainers gave a positive Kastle-Meyer test, indicative of residual blood contamination, following cleaning and sterilisation. In relation to cleaning method, 34% of hand-scrubbed bands and 32% of hand-scrubbed retainers were positive for residual blood by the Kastle-Meyer test compared with 6% and 3% respectively of ultrasonically cleaned bands and retainers (P < 0.001). If Siqveland matrix bands are re-processed in the assembled state, then adequate pre-sterilisation cleaning cannot be achieved reliably. Ultrasonic baths are significantly more effective than hand cleaning for these items of equipment.

  15. Drug-induced exanthems: correlation of allergy testing with histologic diagnosis.

    PubMed

    Seitz, Cornelia S; Rose, Christian; Kerstan, Andreas; Trautmann, Axel

    2013-11-01

    Skin biopsies are commonly performed to confirm drug-induced exanthem (DIE). However, the relevance of histologic examination in discriminating between DIE and non-DIE (NDIE) is controversial. A retrospective analysis was performed to evaluate the reliability of histologic diagnosis of DIE. In all, 91 patients with a skin biopsy specimen of an acute exanthem temporally related to a single identifiable drug underwent complete allergy testing. Their biopsy specimens were retrospectively re-evaluated by 2 dermatopathologists blinded to the original reports to test for discrimination between DIE versus NDIE. In 35 patients, non-IgE-mediated drug allergy was confirmed by allergy testing, whereas in 56 patients drug hypersensitivity could be excluded. Sensitivity of pathology reports for diagnosis of DIE reached 62.9% with a positive predictive value of 40.7%. Specificity was 41.1% with a negative predictive value of 69.7%. No significant difference in tissue eosinophilia was detected between DIE and NDIE. This was a retrospective study. Dermatopathologic evaluation of skin biopsy specimens is of limited use in differentiating between DIE and NDIE. All efforts should be made to subject these patients to thorough allergy testing for definitely confirming or ruling out drug hypersensitivity. Copyright © 2013 American Academy of Dermatology, Inc. Published by Mosby, Inc. All rights reserved.

  16. Testing of electroformed deposited iridium/powder metallurgy rhenium rockets

    NASA Technical Reports Server (NTRS)

    Reed, Brian D.; Dickerson, Robert

    1996-01-01

    High-temperature, oxidation-resistant chamber materials offer the thermal margin for high performance and extended lifetimes for radiation-cooled rockets. Rhenium (Re) coated with iridium (Ir) allow hours of operation at 2200 C on Earth-storable propellants. One process for manufacturing Ir/Re rocket chambers is the fabrication of Re substrates by powder metallurgy (PM) and the application of Ir coatings by using electroformed deposition (ED). ED Ir coatings, however, have been found to be porous and poorly adherent. The integrity of ED Ir coatings could be improved by densification after the electroforming process. This report summarizes the testing of two 22-N, ED Ir/PM Re rocket chambers that were subjected to post-deposition treatments in an effort to densify the Ir coating. One chamber was vacuum annealed, while the other chamber was subjected to hot isostatic pressure (HIP). The chambers were tested on gaseous oxygen/gaseous hydrogen propellants, at mixture ratios that simulated the oxidizing environments of Earth-storable propellants. ne annealed ED Ir/PM Re chamber was tested for a total of 24 firings and 4.58 hr at a mixture ratio of 4.2. After only 9 firings, the annealed ED Ir coating began to blister and spall upstream of the throat. The blistering and spalling were similar to what had been experienced with unannealed, as-deposited ED Ir coatings. The HIP ED Ir/PM Re chamber was tested for a total of 91 firings and 11.45 hr at mixture ratios of 3.2 and 4.2. The HIP ED Ir coating remained adherent to the Re substrate throughout testing; there were no visible signs of coating degradation. Metallography revealed, however, thinning of the HIP Ir coating and occasional pores in the Re layer upstream of the throat. Pinholes in the Ir coating may have provided a path for oxidation of the Re substrate at these locations. The HIP ED Ir coating proved to be more effective than vacuum annealed and as-deposited ED Ir. Further densification is still required to match the integrity of chemically vapor deposited Ir coatings. Despite this, the successful long duration testing of the HIP ED Ir chamber, in an oxidizing environment comparable to Earth-storable propellants, demonstrated the viability of this Ir/Re rocket fabrication process.

  17. Reliability and validity of the closed kinetic chain upper extremity stability test.

    PubMed

    Lee, Dong-Rour; Kim, Laurentius Jongsoon

    2015-04-01

    [Purpose] The purpose of this study was to examine the reliability and validity of the Closed Kinetic Chain Upper Extremity Stability (CKCUES) test. [Subjects and Methods] A sample of 40 subjects (20 males, 20 females) with and without pain in the upper limbs was recruited. The subjects were tested twice, three days apart to assess the reliability of the CKCUES test. The CKCUES test was performed four times, and the average was calculated using the data of the last 3 tests. In order to test the validity of the CKCUES test, peak torque of internal/external shoulder rotation was measured using an isokinetic dynamometer, and maximum grip strength was measured using a hand dynamometer, and their Pearson correlation coefficients with the average values of the CKCUES test were calculated. [Results] The reliability of the CKCUES test was very high (ICC=0.97). The correlations between the CKCUES test and maximum grip strength (r=0.78-0.79), and the peak torque of internal/external shoulder rotation (r=0.87-0.94) were high indicating its validity. [Conclusion] The reliability and validity of the CKCUES test were high. The CKCUES test is expected to be used for clinical tests on upper limb stability at low price.

  18. A Concept for the HIFiRE 8 Flight Test

    NASA Astrophysics Data System (ADS)

    Alesi, H.; Paull, A.; Smart, M.; Bowcutt, K. G.

    2015-09-01

    HIFiRE 8 is a hypersonic flight test experiment scheduled for launch in late 2018 from the Woomera Test Center in Australia. This project aims to develop a Flight Test Vehicle that will, for the first time, complete 30 seconds of scramjet powered hypersonic flight at a Mach Number of 7.0. The engine used for this flight will be a rectangular to elliptic shape transition scramjet. It will be fuelled with gaseous hydrogen. The flight test engine configuration will be derived using scientific and engineering evaluation in the UQ shock tunnel T4 and other potential ground-based facilities. This paper presents current plans for the HIFiRE 8 trajectory, mission events, airframe and engine designs and also includes descriptions of critical subsystems and associated modelling, simulation and analysis activities.

  19. The intra- and inter-rater reliability of five clinical muscle performance tests in patients with and without neck pain

    PubMed Central

    2013-01-01

    Background This study investigates the reliability of muscle performance tests using cost- and time-effective methods similar to those used in clinical practice. When conducting reliability studies, great effort goes into standardising test procedures to facilitate a stable outcome. Therefore, several test trials are often performed. However, when muscle performance tests are applied in the clinical setting, clinicians often only conduct a muscle performance test once as repeated testing may produce fatigue and pain, thus variation in test results. We aimed to investigate whether cervical muscle performance tests, which have shown promising psychometric properties, would remain reliable when examined under conditions similar to those of daily clinical practice. Methods The intra-rater (between-day) and inter-rater (within-day) reliability was assessed for five cervical muscle performance tests in patients with (n = 33) and without neck pain (n = 30). The five tests were joint position error, the cranio-cervical flexion test, the neck flexor muscle endurance test performed in supine and in a 45°-upright position and a new neck extensor test. Results Intra-rater reliability ranged from moderate to almost perfect agreement for joint position error (ICC ≥ 0.48-0.82), the cranio-cervical flexion test (ICC ≥ 0.69), the neck flexor muscle endurance test performed in supine (ICC ≥ 0.68) and in a 45°-upright position (ICC ≥ 0.41) with the exception of a new test (neck extensor test), which ranged from slight to moderate agreement (ICC = 0.14-0.41). Likewise, inter-rater reliability ranged from moderate to almost perfect agreement for joint position error (ICC ≥ 0.51-0.75), the cranio-cervical flexion test (ICC ≥ 0.85), the neck flexor muscle endurance test performed in supine (ICC ≥ 0.70) and in a 45°-upright position (ICC ≥ 0.56). However, only slight to fair agreement was found for the neck extensor test (ICC = 0.19-0.25). Conclusions Intra- and inter-rater reliability ranged from moderate to almost perfect agreement with the exception of a new test (neck extensor test), which ranged from slight to moderate agreement. The significant variability observed suggests that tests like the neck extensor test and the neck flexor muscle endurance test performed in a 45°-upright position are too unstable to be used when evaluating neck muscle performance. PMID:24299621

  20. GalaxyTBM: template-based modeling by building a reliable core and refining unreliable local regions.

    PubMed

    Ko, Junsu; Park, Hahnbeom; Seok, Chaok

    2012-08-10

    Protein structures can be reliably predicted by template-based modeling (TBM) when experimental structures of homologous proteins are available. However, it is challenging to obtain structures more accurate than the single best templates by either combining information from multiple templates or by modeling regions that vary among templates or are not covered by any templates. We introduce GalaxyTBM, a new TBM method in which the more reliable core region is modeled first from multiple templates and less reliable, variable local regions, such as loops or termini, are then detected and re-modeled by an ab initio method. This TBM method is based on "Seok-server," which was tested in CASP9 and assessed to be amongst the top TBM servers. The accuracy of the initial core modeling is enhanced by focusing on more conserved regions in the multiple-template selection and multiple sequence alignment stages. Additional improvement is achieved by ab initio modeling of up to 3 unreliable local regions in the fixed framework of the core structure. Overall, GalaxyTBM reproduced the performance of Seok-server, with GalaxyTBM and Seok-server resulting in average GDT-TS of 68.1 and 68.4, respectively, when tested on 68 single-domain CASP9 TBM targets. For application to multi-domain proteins, GalaxyTBM must be combined with domain-splitting methods. Application of GalaxyTBM to CASP9 targets demonstrates that accurate protein structure prediction is possible by use of a multiple-template-based approach, and ab initio modeling of variable regions can further enhance the model quality.

  1. Analytical Validation of the ReEBOV Antigen Rapid Test for Point-of-Care Diagnosis of Ebola Virus Infection.

    PubMed

    Cross, Robert W; Boisen, Matthew L; Millett, Molly M; Nelson, Diana S; Oottamasathien, Darin; Hartnett, Jessica N; Jones, Abigal B; Goba, Augustine; Momoh, Mambu; Fullah, Mohamed; Bornholdt, Zachary A; Fusco, Marnie L; Abelson, Dafna M; Oda, Shunichiro; Brown, Bethany L; Pham, Ha; Rowland, Megan M; Agans, Krystle N; Geisbert, Joan B; Heinrich, Megan L; Kulakosky, Peter C; Shaffer, Jeffrey G; Schieffelin, John S; Kargbo, Brima; Gbetuwa, Momoh; Gevao, Sahr M; Wilson, Russell B; Saphire, Erica Ollmann; Pitts, Kelly R; Khan, Sheik Humarr; Grant, Donald S; Geisbert, Thomas W; Branco, Luis M; Garry, Robert F

    2016-10-15

    Ebola virus disease (EVD) is a severe viral illness caused by Ebola virus (EBOV). The 2013-2016 EVD outbreak in West Africa is the largest recorded, with >11 000 deaths. Development of the ReEBOV Antigen Rapid Test (ReEBOV RDT) was expedited to provide a point-of-care test for suspected EVD cases. Recombinant EBOV viral protein 40 antigen was used to derive polyclonal antibodies for RDT and enzyme-linked immunosorbent assay development. ReEBOV RDT limits of detection (LOD), specificity, and interference were analytically validated on the basis of Food and Drug Administration (FDA) guidance. The ReEBOV RDT specificity estimate was 95% for donor serum panels and 97% for donor whole-blood specimens. The RDT demonstrated sensitivity to 3 species of Ebolavirus (Zaire ebolavirus, Sudan ebolavirus, and Bundibugyo ebolavirus) associated with human disease, with no cross-reactivity by pathogens associated with non-EBOV febrile illness, including malaria parasites. Interference testing exhibited no reactivity by medications in common use. The LOD for antigen was 4.7 ng/test in serum and 9.4 ng/test in whole blood. Quantitative reverse transcription-polymerase chain reaction testing of nonhuman primate samples determined the range to be equivalent to 3.0 × 10 5 -9.0 × 10 8 genomes/mL. The analytical validation presented here contributed to the ReEBOV RDT being the first antigen-based assay to receive FDA and World Health Organization emergency use authorization for this EVD outbreak, in February 2015. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  2. Intertester and intratester reliability of movement control tests on the hip for patients with hip osteoarthritis.

    PubMed

    Lenzlinger-Asprion, Rahel; Keller, Niculina; Meichtry, André; Luomajoki, Hannu

    2017-01-31

    Hip joint complaints are a problem associated with increasing age and impair the mobility of a large section of the elderly population. Reliable and valid tests are necessary for a thorough investigation of a joint. A fundamental function of the hip joint is movement control and a test of this function forms a part of the standard examination. Until now there have been few scientific studies which specifically investigate the reliability of measurement tests of movement control of the hip joint. The aim of this study was to examine the intratester and intertester reliability of the movement control tests of the hip joint which are in use in current clinical practice. Sixteen participants with hip joint complaints and 14 without hip joint impairment were recruited. All participants performed five active movement control tests for the hip joint and were video filmed whilst performing these tests. These films formed the basis for the evaluation and were assessed by two independent physiotherapists. For the intertester and intratester reliability calculations specially set weighted kappa values and the calculated percentages were used. The intertester reliability of the five examined movement control tests of the hip joint showed good to almost perfect values (weighted kappa (wk) = 0.56-0.87). The intratester reliability of the more experienced evaluator A was better in regards to the less experienced evaluator B (average wk = 0.62 vs 0.38). The visual evaluation of movement control tests of the hip joint is especially reliable when carried out by an experienced evaluator. 4 out of 5 tests also showed good results for intertester reliability and support their use in clinical practice.

  3. The development and validation of a golf swing and putt skill assessment for children.

    PubMed

    Barnett, Lisa M; Hardy, Louise L; Brian, Ali S; Robertson, Sam

    2015-03-01

    The aim was to describe development of a process-oriented instrument designed to assess the golf swing and putt stroke, and to assess the instrument's discriminative validity in terms of age and reliability (intra-rater and re-test). A Delphi consultation (with golf industry professionals and researchers in movement skill assessment) was used to develop an assessment for each skill based on existing skill assessment protocols. Each skill had six components to be marked as present/absent. Individual scores were based on the number of performance components successfully demonstrated over two trials for each skill (potential score range 0 to 24). Children (n = 43) aged 6-10 years (M = 7.8 years, SD = 1.3) were assessed in both skills live in the field by one rater at Time 1(T1). A subset of children (n = 28) had consent for assessments to be videoed. Six weeks later 19 children were reassessed, five days apart (T2, T3). An ANOVA assessed discriminative validity i.e. whether skill competence at T1 differed by age (6 years, 7/8 years and 9/10 years). Intraclass correlations (ICC) assessed intra-rater reliability between the live and video assessment at T1 and test-retest reliability (between T2 and T3). Paired t-tests assessed any systematic differences between live and video assessments (T1) and between T2 and T3. Older children were more skilled (F (2, 40) = 11.18, p < 0.001). The live assessment reflected the video assessment (ICC = 0.79, 95% CI 0.59, 0.90) and scores did not differ between live and video assessments. Test retest reliability was acceptable (ICC = 0.60, 95% CI 0.23, 0.82), although the mean score was slightly higher at retest. This instrument could be used reliably by golf coaches and physical education teachers as part of systematic early player assessment and feedback. Key pointsGolf is becoming an increasingly popular sport among young children, however there is no standard protocol available to assess and identify skill deficits, mastery level, and talent identification in beginner young golf players.Process rather than product oriented outcomes better identify areas of skill deficit in young children.The proposed swing and putt instrument can reliably identify skill deficits in children of elementary school age who are new to golf and can be used by a range of stakeholders including golf coaches, generalist sport coaches and physical education teachers.

  4. The Development and Validation of a Golf Swing and Putt Skill Assessment for Children

    PubMed Central

    Barnett, Lisa M.; Hardy, Louise L.; Brian, Ali S.; Robertson, Sam

    2015-01-01

    The aim was to describe development of a process-oriented instrument designed to assess the golf swing and putt stroke, and to assess the instrument’s discriminative validity in terms of age and reliability (intra-rater and re-test). A Delphi consultation (with golf industry professionals and researchers in movement skill assessment) was used to develop an assessment for each skill based on existing skill assessment protocols. Each skill had six components to be marked as present/absent. Individual scores were based on the number of performance components successfully demonstrated over two trials for each skill (potential score range 0 to 24). Children (n = 43) aged 6-10 years (M = 7.8 years, SD = 1.3) were assessed in both skills live in the field by one rater at Time 1(T1). A subset of children (n = 28) had consent for assessments to be videoed. Six weeks later 19 children were reassessed, five days apart (T2, T3). An ANOVA assessed discriminative validity i.e. whether skill competence at T1 differed by age (6 years, 7/8 years and 9/10 years). Intraclass correlations (ICC) assessed intra-rater reliability between the live and video assessment at T1 and test-retest reliability (between T2 and T3). Paired t-tests assessed any systematic differences between live and video assessments (T1) and between T2 and T3. Older children were more skilled (F (2, 40) = 11.18, p < 0.001). The live assessment reflected the video assessment (ICC = 0.79, 95% CI 0.59, 0.90) and scores did not differ between live and video assessments. Test retest reliability was acceptable (ICC = 0.60, 95% CI 0.23, 0.82), although the mean score was slightly higher at retest. This instrument could be used reliably by golf coaches and physical education teachers as part of systematic early player assessment and feedback. Key points Golf is becoming an increasingly popular sport among young children, however there is no standard protocol available to assess and identify skill deficits, mastery level, and talent identification in beginner young golf players. Process rather than product oriented outcomes better identify areas of skill deficit in young children. The proposed swing and putt instrument can reliably identify skill deficits in children of elementary school age who are new to golf and can be used by a range of stakeholders including golf coaches, generalist sport coaches and physical education teachers. PMID:25729302

  5. New insights into restless genital syndrome: static mechanical hyperesthesia and neuropathy of the nervus dorsalis clitoridis.

    PubMed

    Waldinger, Marcel D; Venema, Pieter L; van Gils, Ad P G; Schweitzer, Dave H

    2009-10-01

    Systematic study of dysesthetic and paresthetic regions contributing to persistent genital arousal in women with restless genital syndrome (ReGS) is needed for its clinical management. To investigate distinct localizations of ReGS. Twenty-three women, fulfilling all five criteria of persistent genital arousal disorder were included into the study. In-depth interviews, routine and hormonal investigations, electroencephalographs, and magnetic resonance imaging (MRI) of brain and pelvis were performed in all women. The localizations of genital sensations were investigated by physical examination of the ramus inferior of the pubic bone (RIPB) and by sensory testing of the skin of the genital area with a cotton swab (genital tactile mapping test or GTM test). Sensitivity of RIPB, GTM test. Of 23 women included in the study, 18(78%), 16(69%), and 12(52%) reported restless legs syndrome, overactive bladder syndrome, and urethra hypersensitivity. Intolerance of tight clothes and underwear (allodynia or hyperpathia) was reported by 19 (83%) women. All women were diagnosed with ReGS. Sitting aggravated ReGS in 20(87%) women. In all women, MRI showed pelvic varices of different degree in the vagina (91%), labia minora and/or majora (35%), and uterus (30%). Finger touch investigation of the dorsal nerve of the clitoris (DNC) along the RIPB provoked ReGS in all women. Sensory testing showed unilateral and bilateral static mechanical Hyperesthesia on various trigger points in the dermatome of the pudendal nerve, particularly in the part innervated by DNC, including pelvic bone. In three women, sensory testing induced an uninhibited orgasm during physical examination. ReGS is highly associated with pelvic varices and with sensory neuropathy of the pudendal nerve and DNC, whose symptoms are suggestive for small fiber neuropathy (SFN). Physical examination for static mechanical Hyperesthesia is a diagnostic test for ReGS and is recommended for all individuals with complaints of persistent restless genital arousal in absence of sexual desire.

  6. Reliability of movement control tests in the lumbar spine

    PubMed Central

    Luomajoki, Hannu; Kool, Jan; de Bruin, Eling D; Airaksinen, Olavi

    2007-01-01

    Background Movement control dysfunction [MCD] reduces active control of movements. Patients with MCD might form an important subgroup among patients with non specific low back pain. The diagnosis is based on the observation of active movements. Although widely used clinically, only a few studies have been performed to determine the test reliability. The aim of this study was to determine the inter- and intra-observer reliability of movement control dysfunction tests of the lumbar spine. Methods We videoed patients performing a standardized test battery consisting of 10 active movement tests for motor control in 27 patients with non specific low back pain and 13 patients with other diagnoses but without back pain. Four physiotherapists independently rated test performances as correct or incorrect per observation, blinded to all other patient information and to each other. The study was conducted in a private physiotherapy outpatient practice in Reinach, Switzerland. Kappa coefficients, percentage agreements and confidence intervals for inter- and intra-rater results were calculated. Results The kappa values for inter-tester reliability ranged between 0.24 – 0.71. Six tests out of ten showed a substantial reliability [k > 0.6]. Intra-tester reliability was between 0.51 – 0.96, all tests but one showed substantial reliability [k > 0.6]. Conclusion Physiotherapists were able to reliably rate most of the tests in this series of motor control tasks as being performed correctly or not, by viewing films of patients with and without back pain performing the task. PMID:17850669

  7. Test-retest reliability of sensor-based sit-to-stand measures in young and older adults.

    PubMed

    Regterschot, G Ruben H; Zhang, Wei; Baldus, Heribert; Stevens, Martin; Zijlstra, Wiebren

    2014-01-01

    This study investigated test-retest reliability of sensor-based sit-to-stand (STS) peak power and other STS measures in young and older adults. In addition, test-retest reliability of the sensor method was compared to test-retest reliability of the Timed Up and Go Test (TUGT) and Five-Times-Sit-to-Stand Test (FTSST) in older adults. Ten healthy young female adults (20-23 years) and 31 older adults (21 females; 73-94 years) participated in two assessment sessions separated by 3-8 days. Vertical peak power was assessed during three (young adults) and five (older adults) normal and fast STS trials with a hybrid motion sensor worn on the hip. Older adults also performed the FTSST and TUGT. The average sensor-based STS peak power of the normal STS trials and the average sensor-based STS peak power of the fast STS trials showed excellent test-retest reliability in young adults (intra-class correlation (ICC)≥0.90; zero in 95% confidence interval of mean difference between test and retest (95%CI of D); standard error of measurement (SEM)≤6.7% of mean peak power) and older adults (ICC≥0.91; zero in 95%CI of D; SEM≤9.9%). Test-retest reliability of sensor-based STS peak power and TUGT (ICC=0.98; zero in 95%CI of D; SEM=8.5%) was comparable in older adults, test-retest reliability of the FTSST was lower (ICC=0.73; zero outside 95%CI of D; SEM=14.4%). Sensor-based STS peak power demonstrated excellent test-retest reliability and may therefore be useful for clinical assessment of functional status and fall risk. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Reliability of the Cooking Task in adults with acquired brain injury.

    PubMed

    Poncet, Frédérique; Swaine, Bonnie; Taillefer, Chantal; Lamoureux, Julie; Pradat-Diehl, Pascale; Chevignard, Mathilde

    2015-01-01

    Acquired brain injury (ABI) often leads to deficits in executive functioning (EF) responsible for severe and long-standing disabilities in daily life activities. The Cooking Task is an ecological and valid test of EF involving multi-tasking in a real environment. Given its complex scoring system, it is important to establish the tool's reliability. The objective of the study was to examine the reliability of the Cooking Task (internal consistency, inter-rater and test-retest reliability). A total of 160 patients with ABI (113 men, mean age 37 years, SD = 14.3) were tested using the Cooking Task. For test-retest reliability, patients were assessed by the same rater on two occasions (mean interval 11 days) while two raters independently and simultaneously observed and scored patients' performances to estimate inter-rater reliability. Internal consistency was high for the global scale (Cronbach α = .74). Inter-rater reliability (n = 66) for total errors was also high (ICC = .93), however the test-retest reliability (n = 11) was poor (ICC = .36). In general the Cooking Task appears to be a reliable tool. The low test-retest results were expected given the importance of EF in the performance of novel tasks.

  9. Evaluation of tools used to measure calcium and/or dairy consumption in adults.

    PubMed

    Magarey, Anthea; Baulderstone, Lauren; Yaxley, Alison; Markow, Kylie; Miller, Michelle

    2015-05-01

    To identify and critique tools for the assessment of Ca and/or dairy intake in adults, in order to ascertain the most accurate and reliable tools available. A systematic review of the literature was conducted using defined inclusion and exclusion criteria. Articles reporting on originally developed tools or testing the reliability or validity of existing tools that measure Ca and/or dairy intake in adults were included. Author-defined criteria for reporting reliability and validity properties were applied. Studies conducted in Western countries. Adults. Thirty papers, utilising thirty-six tools assessing intake of dairy, Ca or both, were identified. Reliability testing was conducted on only two dairy and five Ca tools, with results indicating that only one dairy and two Ca tools were reliable. Validity testing was conducted for all but four Ca-only tools. There was high reliance in validity testing on lower-order tests such as correlation and failure to differentiate between statistical and clinically meaningful differences. Results of the validity testing suggest one dairy and five Ca tools are valid. Thus one tool was considered both reliable and valid for the assessment of dairy intake and only two tools proved reliable and valid for the assessment of Ca intake. While several tools are reliable and valid, their application across adult populations is limited by the populations in which they were tested. These results indicate a need for tools that assess Ca and/or dairy intake in adults to be rigorously tested for reliability and validity.

  10. Construction of Valid and Reliable Test for Assessment of Students

    ERIC Educational Resources Information Center

    Osadebe, P. U.

    2015-01-01

    The study was carried out to construct a valid and reliable test in Economics for secondary school students. Two research questions were drawn to guide the establishment of validity and reliability for the Economics Achievement Test (EAT). It is a multiple choice objective test of five options with 100 items. A sample of 1000 students was randomly…

  11. Validity and Reliability of the Arabic Token Test for Children

    ERIC Educational Resources Information Center

    Alkhamra, Rana A.; Al-Jazi, Aya B.

    2016-01-01

    Background: The Token Test for Children (2nd edition) (TTFC) is a measure for assessing receptive language. In this study we describe the translation process, validity and reliability of the Arabic Token Test for Children (A-TTFC). Aims: The aim of this study is to translate, validate and establish the reliability of the Arabic Token Test for…

  12. Construction and Evaluation of Reliability and Validity of Reasoning Ability Test

    ERIC Educational Resources Information Center

    Bhat, Mehraj A.

    2014-01-01

    This paper is based on the construction and evaluation of reliability and validity of reasoning ability test at secondary school students. In this paper an attempt was made to evaluate validity, reliability and to determine the appropriate standards to interpret the results of reasoning ability test. The test includes 45 items to measure six types…

  13. Conceptualizing Essay Tests' Reliability and Validity: From Research to Theory

    ERIC Educational Resources Information Center

    Badjadi, Nour El Imane

    2013-01-01

    The current paper on writing assessment surveys the literature on the reliability and validity of essay tests. The paper aims to examine the two concepts in relationship with essay testing as well as to provide a snapshot of the current understandings of the reliability and validity of essay tests as drawn in recent research studies. Bearing in…

  14. Estimation of light commercial vehicles dynamics by means of HIL-testbench simulation

    NASA Astrophysics Data System (ADS)

    Groshev, A.; Tumasov, A.; Toropov, E.; Sereda, P.

    2018-02-01

    The high level of active safety of vehicles is impossible without driver assistance electronic systems. Electronic stability control (ESC) system is one of them. Nowadays such systems are obligatory for installation on vehicles of different categories. The approval of active safety level of vehicles with ESC is possible by means of high speed road tests. The most frequently implemented tests are “fish hook” and “sine with dwell” tests. Such kind of tests provided by The Global technical regulation No. 8 are published by the United Nations Economic Commission for Europe as well as by ECE 13-11. At the same time, not only road tests could be used for estimation of vehicles dynamics. Modern software and hardware technologies allow imitating real tests with acceptable reliability and good convergence between real test data and simulation results. ECE 13-11 Annex 21 - Appendix 1 “Use Of The Dynamic Stability Simulation” regulates demands for special Simulation Test bench that could be used not only for preliminary estimation of vehicles dynamics, but also for official vehicles homologation. This paper describes the approach, proposed by the researchers from Nizhny Novgorod State Technical University n.a. R.E. Alekseev (NNSTU, Russia) with support of engineers of United Engineering Center GAZ Group, as well as specialists of Gorky Automobile Plant. The idea of approach is to use the special HIL (hardware in the loop) -test bench, that consists of Real Time PC with Real Time Software and braking system components including electronic control unit (ECU) of ESC system. The HIL-test bench allows imitating vehicle dynamics in condition of “fish hook” and “sine with dwell” tests. The paper describes the scheme and structure of HIL-test bench and some peculiarities that should be taken into account during HIL-simulation.

  15. FY12 End of Year Report for NEPP DDR2 Reliability

    NASA Technical Reports Server (NTRS)

    Guertin, Steven M.

    2013-01-01

    This document reports the status of the NASA Electronic Parts and Packaging (NEPP) Double Data Rate 2 (DDR2) Reliability effort for FY2012. The task expanded the focus of evaluating reliability effects targeted for device examination. FY11 work highlighted the need to test many more parts and to examine more operating conditions, in order to provide useful recommendations for NASA users of these devices. This year's efforts focused on development of test capabilities, particularly focusing on those that can be used to determine overall lot quality and identify outlier devices, and test methods that can be employed on components for flight use. Flight acceptance of components potentially includes considerable time for up-screening (though this time may not currently be used for much reliability testing). Manufacturers are much more knowledgeable about the relevant reliability mechanisms for each of their devices. We are not in a position to know what the appropriate reliability tests are for any given device, so although reliability testing could be focused for a given device, we are forced to perform a large campaign of reliability tests to identify devices with degraded reliability. With the available up-screening time for NASA parts, it is possible to run many device performance studies. This includes verification of basic datasheet characteristics. Furthermore, it is possible to perform significant pattern sensitivity studies. By doing these studies we can establish higher reliability of flight components. In order to develop these approaches, it is necessary to develop test capability that can identify reliability outliers. To do this we must test many devices to ensure outliers are in the sample, and we must develop characterization capability to measure many different parameters. For FY12 we increased capability for reliability characterization and sample size. We increased sample size this year by moving from loose devices to dual inline memory modules (DIMMs) with an approximate reduction of 20 to 50 times in terms of per device under test (DUT) cost. By increasing sample size we have improved our ability to characterize devices that may be considered reliability outliers. This report provides an update on the effort to improve DDR2 testing capability. Although focused on DDR2, the methods being used can be extended to DDR and DDR3 with relative ease.

  16. Development, construct validity and test-retest reliability of a field-based wheelchair mobility performance test for wheelchair basketball.

    PubMed

    de Witte, Annemarie M H; Hoozemans, Marco J M; Berger, Monique A M; van der Slikke, Rienk M A; van der Woude, Lucas H V; Veeger, Dirkjan H E J

    2018-01-01

    The aim of this study was to develop and describe a wheelchair mobility performance test in wheelchair basketball and to assess its construct validity and reliability. To mimic mobility performance of wheelchair basketball matches in a standardised manner, a test was designed based on observation of wheelchair basketball matches and expert judgement. Forty-six players performed the test to determine its validity and 23 players performed the test twice for reliability. Independent-samples t-tests were used to assess whether the times needed to complete the test were different for classifications, playing standards and sex. Intraclass correlation coefficients (ICC) were calculated to quantify reliability of performance times. Males performed better than females (P < 0.001, effect size [ES] = -1.26) and international men performed better than national men (P < 0.001, ES = -1.62). Performance time of low (≤2.5) and high (≥3.0) classification players was borderline not significant with a moderate ES (P = 0.06, ES = 0.58). The reliability was excellent for overall performance time (ICC = 0.95). These results show that the test can be used as a standardised mobility performance test to validly and reliably assess the capacity in mobility performance of elite wheelchair basketball athletes. Furthermore, the described methodology of development is recommended for use in other sports to develop sport-specific tests.

  17. Effects of a new sensory re-education training tool on hand sensibility and manual dexterity in people with multiple sclerosis.

    PubMed

    Kalron, Alon; Greenberg-Abrahami, Michal; Gelav, Simona; Achiron, Anat

    2013-01-01

    To describe and evaluate the effects of a new home-based sensory re-education training tool on hand sensibility and manual dexterity in people with MS experiencing upper limb sensory deficits. Twenty-five people with relapsing-remitting MS (18 women), mean age 50.6 years (SD = 11.4), volunteered to participate. Participants were initially assigned to a 7-week control phase followed by a 3-week home-based sensory re-education phase. Measurements used were the nine-hole peg test, the two point discrimination test, the monofilaments test and the functional dexterity test. Measurements were collected at baseline, following the control phase and at the end of the trial. Participants demonstrated an improvement in the nine-hole peg (26.8 (SD = 3.5) vs. 22.6 (SD = 3.2); mean difference (95% CI) 4.9 (0.9, 7.1), P = 0.03) and functional dexterity tests (38.6 (SD = 4.4) vs. 33.8 (SD = 4.9); mean difference (95% CI) 4.8 (1.8, 7.0); P = 0.02) at the end of the sensory re-education phase compared to the end of the control phase. No differences were observed as to the monofilaments and two-point discrimination tests. Sensory re-education training does not affect the level of sensory impairment in the hand but may lead to improvement in select measures of manual dexterity.

  18. Renewable energy consumption and economic growth in nine OECD countries: bounds test approach and causality analysis.

    PubMed

    Hung-Pin, Lin

    2014-01-01

    The purpose of this paper is to investigate the short-run and long-run causality between renewable energy (RE) consumption and economic growth (EG) in nine OECD countries from the period between 1982 and 2011. To examine the linkage, this paper uses the autoregressive distributed lag (ARDL) bounds testing approach of cointegration test and vector error-correction models to test the causal relationship between variables. The co-integration and causal relationships are found in five countries-United States of America (USA), Japan, Germany, Italy, and United Kingdom (UK). The overall results indicate that (1) a short-run unidirectional causality runs from EG to RE in Italy and UK; (2) long-run unidirectional causalities run from RE to EG for Germany, Italy, and UK; (3) a long-run unidirectional causality runs from EG to RE in USA, and Japan; (4) both long-run and strong unidirectional causalities run from RE to EG for Germany and UK; and (5) Finally, both long-run and strong unidirectional causalities run from EG to RE in only USA. Further evidence reveals that policies for renewable energy conservation may have no impact on economic growth in France, Denmark, Portugal, and Spain.

  19. Renewable Energy Consumption and Economic Growth in Nine OECD Countries: Bounds Test Approach and Causality Analysis

    PubMed Central

    Hung-Pin, Lin

    2014-01-01

    The purpose of this paper is to investigate the short-run and long-run causality between renewable energy (RE) consumption and economic growth (EG) in nine OECD countries from the period between 1982 and 2011. To examine the linkage, this paper uses the autoregressive distributed lag (ARDL) bounds testing approach of cointegration test and vector error-correction models to test the causal relationship between variables. The co-integration and causal relationships are found in five countries—United States of America (USA), Japan, Germany, Italy, and United Kingdom (UK). The overall results indicate that (1) a short-run unidirectional causality runs from EG to RE in Italy and UK; (2) long-run unidirectional causalities run from RE to EG for Germany, Italy, and UK; (3) a long-run unidirectional causality runs from EG to RE in USA, and Japan; (4) both long-run and strong unidirectional causalities run from RE to EG for Germany and UK; and (5) Finally, both long-run and strong unidirectional causalities run from EG to RE in only USA. Further evidence reveals that policies for renewable energy conservation may have no impact on economic growth in France, Denmark, Portugal, and Spain. PMID:24558343

  20. A reliability generalization meta-analysis of coefficient alpha and test-retest coefficient for the aging males' symptoms (AMS) scale.

    PubMed

    Lee, Chin-Pang; Chiu, Yu-Wen; Chu, Chun-Lin; Chen, Yu; Jiang, Kun-Hao; Chen, Jiun-Liang; Chen, Ching-Yen

    2016-12-01

    The aging males' symptoms (AMS) scale is an instrument used to determine the health-related quality of life in adult and elderly men. The purpose of this study was to synthesize internal consistency (Cronbach's alpha) and test-retest reliability for the AMS scale and its three subscales. Of the 123 studies reviewed, 12 provided alpha coefficients which were then used in the meta-analyses of internal consistency. Seven of the 12 included studies provided test-retest coefficients, and these were used in the meta-analyses of test-retest reliability. The AMS scale had excellent internal consistency [α = 0.89 (95% CI 0.88-0.90)]; the mean alpha estimates across the AMS subscales ranged from 0.79 to 0.82. The AMS scale also had good test-retest reliability [r = 0.85 (95% CI 0.82-0.88]; the test-retest reliability coefficients of the AMS subscales ranged from 0.76 to 0.83. There was significant heterogeneity among the included studies. The AMS scale and the three subscales had fairly good internal consistency and test-retest reliability. Future psychometric studies of the AMS scale should report important characteristics of the participants, details of item scores, and test-retest reliability.

  1. High-Temperature Oxidation Behavior of Iridium-Rhenium Alloys

    NASA Technical Reports Server (NTRS)

    Reed, Brian D.

    1995-01-01

    The life-limiting mechanism for radiation-cooled rockets made from iridium-coated rhenium (Ir/Re) is the diffusion of Re into the Ir layer and the subsequent oxidation of the resulting Ir-Re alloy from the inner surface. In a previous study, a life model for Ir/Re rockets was developed. It incorporated Ir-Re diffusion and oxidation data to predict chamber lifetimes as a function of temperature and oxygen partial pressure. Oxidation testing at 1540 deg C suggested that a 20-wt percent Re concentration at the inner wall surface should be established as the failure criterion. The present study was performed to better define Ir-oxidation behavior as a function of Re concentration and to supplement the data base for the life model. Samples ranging from pure Ir to Ir-40 wt percent Re (Ir-40Re) were tested at 1500 deg C, in two different oxygen environments. There were indications that the oxidation rate of the Ir-Re alloy increased significantly when it went from a single-phase solid solution to a two-phase mixture, as was suggested in previous work. However, because of testing anomalies in this study, there were not enough dependable oxidation data to definitively raise the Ir/Re rocket failure criterion from 20-wt percent Re to a Re concentration corresponding to entry into the two-phase region.

  2. TCOPPE school environmental audit tool: assessing safety and walkability of school environments.

    PubMed

    Lee, Chanam; Kim, Hyung Jin; Dowdy, Diane M; Hoelscher, Deanna M; Ory, Marcia G

    2013-09-01

    Several environmental audit instruments have been developed for assessing streets, parks and trails, but none for schools. This paper introduces a school audit tool that includes 3 subcomponents: 1) street audit, 2) school site audit, and 3) map audit. It presents the conceptual basis and the development process of this instrument, and the methods and results of the reliability assessments. Reliability tests were conducted by 2 trained auditors on 12 study schools (high-low income and urban-suburban-rural settings). Kappa statistics (categorical, factual items) and ICC (Likert-scale, perceptual items) were used to assess a) interrater, b) test-retest, and c) peak vs. off-peak hour reliability tests. For the interrater reliability test, the average Kappa was 0.839 and the ICC was 0.602. For the test-retest reliability, the average Kappa was 0.903 and the ICC was 0.774. The peak-off peak reliability was 0.801. Rural schools showed the most consistent results in the peak-off peak and test-retest assessments. For interrater tests, urban schools showed the highest ICC, and rural schools showed the highest Kappa. Most items achieved moderate to high levels of reliabilities in all study schools. With proper training, this audit can be used to assess school environments reliably for research, outreach, and policy-support purposes.

  3. ENVIRONMENTAL TECHNOLOGY VERIFICATION: Reduction of Nitrogen in Domestic Wastewater from Individual Residential Homes. BioConcepts, Inc. ReCip® RTS ~ 500 System

    EPA Science Inventory

    Verification testing of the ReCip® RTS-500 System was conducted over a 12-month period at the Massachusetts Alternative Septic System Test Center (MASSTC) located on Otis Air National Guard Base in Bourne, Massachusetts. A nine-week startup period preceded the verification test t...

  4. Reliability of physical examination tests for the diagnosis of knee disorders: Evidence from a systematic review.

    PubMed

    Décary, Simon; Ouellet, Philippe; Vendittoli, Pascal-André; Desmeules, François

    2016-12-01

    Clinicians often rely on physical examination tests to guide them in the diagnostic process of knee disorders. However, reliability of these tests is often overlooked and may influence the consistency of results and overall diagnostic validity. Therefore, the objective of this study was to systematically review evidence on the reliability of physical examination tests for the diagnosis of knee disorders. A structured literature search was conducted in databases up to January 2016. Included studies needed to report reliability measures of at least one physical test for any knee disorder. Methodological quality was evaluated using the QAREL checklist. A qualitative synthesis of the evidence was performed. Thirty-three studies were included with a mean QAREL score of 5.5 ± 0.5. Based on low to moderate quality evidence, the Thessaly test for meniscal injuries reached moderate inter-rater reliability (k = 0.54). Based on moderate to excellent quality evidence, the Lachman for anterior cruciate ligament injuries reached moderate to excellent inter-rater reliability (k = 0.42 to 0.81). Based on low to moderate quality evidence, the Tibiofemoral Crepitus, Joint Line and Patellofemoral Pain/Tenderness, Bony Enlargement and Joint Pain on Movement tests for knee osteoarthritis reached fair to excellent inter-rater reliability (k = 0.29 to 0.93). Based on low to moderate quality evidence, the Lateral Glide, Lateral Tilt, Lateral Pull and Quality of Movement tests for patellofemoral pain reached moderate to good inter-rater reliability (k = 0.49 to 0.73). Many physical tests appear to reach good inter-rater reliability, but this is based on low-quality and conflicting evidence. High-quality research is required to evaluate the reliability of knee physical examination tests. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. HIFiRE Direct-Connect Rig (HDCR) Phase I Scramjet Test Results from the NASA Langley Arc-Heated Scramjet Test Facility

    NASA Technical Reports Server (NTRS)

    Cabell, Karen; Hass, Neal; Storch, Andrea; Gruber, Mark

    2011-01-01

    A series of hydrocarbon-fueled direct-connect scramjet ground tests has been completed in the NASA Langley Arc-Heated Scramjet Test Facility (AHSTF) at simulated Mach 8 flight conditions. These experiments were part of an initial test phase to support Flight 2 of the Hypersonic International Flight Research Experimentation (HIFiRE) Program. In this flight experiment, a hydrocarbon-fueled scramjet is intended to demonstrate transition from dual-mode to scramjet-mode operation and verify the scramjet performance prediction and design tools A performance goal is the achievement of a combusted fuel equivalence ratio greater than 0.7 while in scramjet mode. The ground test rig, designated the HIFiRE Direct Connect Rig (HDCR), is a full-scale, heat sink test article that duplicates both the flowpath lines and a majority of the instrumentation layout of the isolator and combustor portion of the flight test hardware. The primary objectives of the HDCR Phase I tests were to verify the operability of the HIFiRE isolator/combustor across the simulated Mach 6-8 flight regime and to establish a fuel distribution schedule to ensure a successful mode transition. Both of these objectives were achieved prior to the HiFIRE Flight 2 payload Critical Design Review. Mach 8 ground test results are presented in this report, including flowpath surface pressure distributions that demonstrate the operation of the flowpath in scramjet-mode over a small range of test conditions around the nominal Mach 8 simulation, as well as over a range of fuel equivalence ratios. Flowpath analysis using ground test data is presented elsewhere; however, limited comparisons with analytical predictions suggest that both scramjet-mode operation and the combustion performance objective are achieved at Mach 8 conditions.

  6. Tool development to assess the work related neck and upper limb musculoskeletal disorders among female garment workers in Sri-Lanka.

    PubMed

    Amarasinghe, Nirmalie Champika; De AlwisSenevirathne, Rohini

    2016-10-17

    Musculoskeletal disorders (MSDs) have been identified as a predisposing factor for lesser productivity, but no validated tool has been developed to assess them in the Sri- Lankan context. To develop a validated tool to assess the neck and upper limb MSDs. It comprises three components: item selections, item reduction using principal component analysis, and validation. A tentative self-administrated questionnaire was developed, translated, and pre-tested. Four important domains - neck, shoulder, elbow and wrist - were identified through principal component analysis. Prevalence of any MSDs was 38.1% and prevalence of neck, shoulder, elbow and wrist MSDs are 12.85%, 13.71%, 12%, 13.71% respectively. Content and criterion validity of the tool was assessed. Separate ROC curves were produced and sensitivity and specificity of neck (83.1%, 71.7%), shoulder (97.6%, 91.9%), elbow (98.2%, 87.2%), and wrist (97.6%, 94.9%) was determined. Cronbach's Alpha and correlation coefficient was above 0.7. The tool has high sensitivity, specificity, internal consistency, and test re-test reliability.

  7. Reliability of Fitness Tests Using Methods and Time Periods Common in Sport and Occupational Management

    PubMed Central

    Burnstein, Bryan D.; Steele, Russell J.; Shrier, Ian

    2011-01-01

    Context: Fitness testing is used frequently in many areas of physical activity, but the reliability of these measurements under real-world, practical conditions is unknown. Objective: To evaluate the reliability of specific fitness tests using the methods and time periods used in the context of real-world sport and occupational management. Design: Cohort study. Setting: Eighteen different Cirque du Soleil shows. Patients or Other Participants: Cirque du Soleil physical performers who completed 4 consecutive tests (6-month intervals) and were free of injury or illness at each session (n = 238 of 701 physical performers). Intervention(s): Performers completed 6 fitness tests on each assessment date: dynamic balance, Harvard step test, handgrip, vertical jump, pull-ups, and 60-second jump test. Main Outcome Measure(s): We calculated the intraclass coefficient (ICC) and limits of agreement between baseline and each time point and the ICC over all 4 time points combined. Results: Reliability was acceptable (ICC > 0.6) over an 18-month time period for all pairwise comparisons and all time points together for the handgrip, vertical jump, and pull-up assessments. The Harvard step test and 60-second jump test had poor reliability (ICC < 0.6) between baseline and other time points. When we excluded the baseline data and calculated the ICC for 6-month, 12-month, and 18-month time points, both the Harvard step test and 60-second jump test demonstrated acceptable reliability. Dynamic balance was unreliable in all contexts. Limit-of-agreement analysis demonstrated considerable intraindividual variability for some tests and a learning effect by administrators on others. Conclusions: Five of the 6 tests in this battery had acceptable reliability over an 18-month time frame, but the values for certain individuals may vary considerably from time to time for some tests. Specific tests may require a learning period for administrators. PMID:22488138

  8. Robot-Powered Reliability Testing at NREL's ESIF Video Text Version |

    Science.gov Websites

    Video Text Version Robot-Powered Reliability Testing at NREL's ESIF Video Text Version Below is the text version for the Robot-Powered Reliability Testing at NREL's ESIF video. [Text on screen] Robot-Powered

  9. Mechanical property, biocorrosion and in vitro biocompatibility evaluations of Mg-Li-(Al)-(RE) alloys for future cardiovascular stent application.

    PubMed

    Zhou, W R; Zheng, Y F; Leeflang, M A; Zhou, J

    2013-11-01

    Mg-Li-based alloys were investigated for future cardiovascular stent application as they possess excellent ductility. However, Mg-Li binary alloys exhibited reduced mechanical strengths due to the presence of lithium. To improve the mechanical strengths of Mg-Li binary alloys, aluminum and rare earth (RE) elements were added to form Mg-Li-Al ternary and Mg-Li-Al-RE quarternary alloys. In the present study, six Mg-Li-(Al)-(RE) alloys were fabricated. Their microstructures, mechanical properties and biocorrosion behavior were evaluated by using optical microscopy, X-ray diffraction, scanning electronic microscopy, tensile tests, immersion tests and electrochemical measurements. Microstructure characterization indicated that grain sizes were moderately refined by the addition of rare earth elements. Tensile testing showed that enhanced mechanical strengths were obtained, while electrochemical and immersion tests showed reduced corrosion resistance caused by intermetallic compounds distributed throughout the magnesium matrix in the rare-earth-containing Mg-Li alloys. Cytotoxicity assays, hemolysis tests as well as platelet adhesion tests were performed to evaluate in vitro biocompatibilities of the Mg-Li-based alloys. The results of cytotoxicity assays clearly showed that the Mg-3.5Li-2Al-2RE, Mg-3.5Li-4Al-2RE and Mg-8.5Li-2Al-2RE alloys suppressed vascular smooth muscle cell proliferation after 5day incubation, while the Mg-3.5Li, Mg-8.5Li and Mg-8.5Li-1Al alloys were proven to be tolerated. In the case of human umbilical vein endothelial cells, the Mg-Li-based alloys showed no significantly reduced cell viabilities except for the Mg-8.5Li-2Al-2RE alloy, with no obvious differences in cell viability between different culture periods. With the exception of Mg-8.5Li-2Al-2RE, all of the other Mg-Li-(Al)-(RE) alloys exhibited acceptable hemolysis ratios, and no sign of thrombogenicity was found. These in vitro experimental results indicate the potential of Mg-Li-(Al)-(RE) alloys as biomaterials for future cardiovascular stent application and the worthiness of investigating their biodegradation behaviors in vivo. Copyright © 2013 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  10. Psychometric Properties of the Spanish Version of the Panic Disorder Severity Scale.

    PubMed

    Fuste, Gideoni; Gil, María Ángeles; López-Solà, Clara; Rosado, Silvia; Bonillo, Albert; Pailhez, Guillem; Bulbena, Antoni; Pérez, Víctor; Fullana, Miguel A

    2018-03-25

    The Panic Disorder Severity Scale (PDSS) is a well-established measure of panic symptoms but few data exist on this instrument in non north-American samples. Our main goal was to assess the psychometric properties (internal consistency, test re-test reliability, inter-rater reliability, convergent and divergent validity) and the factor structure of the Spanish version. Ninety-four patients with a main diagnosis of panic disorder were assessed with the Spanish version of PDSS, the Anxiety Sensitivity Index-3 (ASI-3), the Panic and Agoraphobia Scale (PAS), the Beck Anxiety Inventory (BAI), the Beck Depression Inventory-II (BDI-II) the PDSS self-rating form and the Clinical Global Impression-Severity scale (CGI). The Spanish PDSS showed acceptable internal consistency (α = .74), excellent test-retest (total score and items 1-6: α > .58, p .90) and medium to large convergent validity (r = .68, 95% CI [.54, .79], p < .01; r = .80, 95% CI [.70, .87], p < .01; r = .48, 95% CI [.28, .67], p < .01; BAI, PAS and ASI-3 total scores respectively). Data on divergent validity (BDI-II total score: r = .52, 95% CI [.34, .67], p < .01) suggest some need for refinement of the PDSS. The confirmatory factor analysis suggested a two-factor modified model for the scale (nested χ2 = 14.01, df = 12, p < .001). The Spanish PDSS has similar psychometric properties as the previous versions and is a useful instrument to assess panic symptoms in clinical settings in Spanish-speaking populations.

  11. Assuring Electronics Reliability: What Could and Should Be Done Differently

    NASA Astrophysics Data System (ADS)

    Suhir, E.

    The following “ ten commandments” for the predicted and quantified reliability of aerospace electronic, and photonic products are addressed and discussed: 1) The best product is the best compromise between the needs for reliability, cost effectiveness and time-to-market; 2) Reliability cannot be low, need not be higher than necessary, but has to be adequate for a particular product; 3) When reliability is imperative, ability to quantify it is a must, especially if optimization is considered; 4) One cannot design a product with quantified, optimized and assured reliability by limiting the effort to the highly accelerated life testing (HALT) that does not quantify reliability; 5) Reliability is conceived at the design stage and should be taken care of, first of all, at this stage, when a “ genetically healthy” product should be created; reliability evaluations and assurances cannot be delayed until the product is fabricated and shipped to the customer, i.e., cannot be left to the prognostics-and-health-monitoring/managing (PHM) stage; it is too late at this stage to change the design or the materials for improved reliability; that is why, when reliability is imperative, users re-qualify parts to assess their lifetime and use redundancy to build a highly reliable system out of insufficiently reliable components; 6) Design, fabrication, qualification and PHM efforts should consider and be specific for particular products and their most likely actual or at least anticipated application(s); 7) Probabilistic design for reliability (PDfR) is an effective means for improving the state-of-the-art in the field: nothing is perfect, and the difference between an unreliable product and a robust one is “ merely” the probability of failure (PoF); 8) Highly cost-effective and highly focused failure oriented accelerated testing (FOAT) geared to a particular pre-determined reliability model and aimed at understanding the physics of failure- anticipated by this model is an important constituent part of the PDfR effort; 9) Predictive modeling (PM) is another important constituent of the PDfR approach; in combination with FOAT, it is a powerful means to carry out sensitivity analyses (SA), to quantify and nearly eliminate failures (“ principle of practical confidence” ); 10) Consistent, comprehensive and physically meaningful PDfR can effectively contribute to the most feasible and the most effective qualification test (QT) methodologies, practices and specifications. The general concepts addressed in the paper are illustrated by numerical examples. It is concluded that although the suggested concept is promising and fruitful, further research, refinement, and validations are needed before this concept becomes widely accepted by the engineering community and implemented into practice. It is important that this novel approach is introduced gradually, whenever feasible and appropriate, in addition to, and in some situations even instead of, the currently employed various types and modifications of the forty year old HALT.

  12. Monitoring Thyroid Function in Patients on Levothyroxine. Assessment of Conformity to National Guidance and Variability in Practice.

    PubMed

    Scargill, Jonathan J; Livingston, Mark; Holland, David; Duff, Christopher J; Fryer, Anthony A; Heald, Adrian H

    2017-10-01

    With demand for endocrine tests steadily increasing year-on-year, we examined thyroid function test (TFT) frequencies in patients on levothyroxine replacement therapy to assess the effect of initial TFT results and request source on TFT re-testing interval. All TFTs performed by the Clinical Biochemistry Departments at the Salford Royal Hospital (2009-2012; 288 263 requests from 139 793 patients) and University Hospital of North Midlands (2011-2014; 579 156 requests from 193 035 patients) were extracted from the laboratory computer systems. Of these, 54 894 tests were on 13 297 patients confirmed to be on levothyroxine therapy in the test cohort (Salford) and 67 298 requests on 11 971 patients in the confirmatory cohort (North Midlands). In the test cohort, median TFT re-testing interval in the total group was 19.1 weeks (IQR 9.1-37.7 weeks), with clearly defined peaks in TFT re-testing evident at 6 and 12 months and a prominent broad peak at 1-3 months. Median re-test interval was much lower than recommended (52 weeks) for those with normal TFTs at 31.3 weeks (30.6 weeks for the confirmatory cohort). Where thyroid-stimulating hormone (TSH) was elevated and free thyroxine (fT4) was below the reference range, re-test interval was much longer than is recommended (8 weeks) at 13.4-17.6 weeks (7.1-23.4 weeks in the confirmatory cohort), as was the interval when TSH was below and fT4 was above the normal range, at 16.7-25.6 weeks (27.5-31.9 weeks in the confirmatory cohort). Our findings show that the majority of TFT requests are requested outside recommended intervals and within-practice variability is high. A new approach to ensuring optimum monitoring frequency is required. Direct requesting from the clinical laboratory may provide one such solution. © Georg Thieme Verlag KG Stuttgart · New York.

  13. Measuring verbal and non-verbal communication in aphasia: reliability, validity, and sensitivity to change of the Scenario Test.

    PubMed

    van der Meulen, Ineke; van de Sandt-Koenderman, W Mieke E; Duivenvoorden, Hugo J; Ribbers, Gerard M

    2010-01-01

    This study explores the psychometric qualities of the Scenario Test, a new test to assess daily-life communication in severe aphasia. The test is innovative in that it: (1) examines the effectiveness of verbal and non-verbal communication; and (2) assesses patients' communication in an interactive setting, with a supportive communication partner. To determine the reliability, validity, and sensitivity to change of the Scenario Test and discuss its clinical value. The Scenario Test was administered to 122 persons with aphasia after stroke and to 25 non-aphasic controls. Analyses were performed for the entire group of persons with aphasia, as well as for a subgroup of persons unable to communicate verbally (n = 43). Reliability (internal consistency, test-retest reliability, inter-judge, and intra-judge reliability) and validity (internal validity, convergent validity, known-groups validity) and sensitivity to change were examined using standard psychometric methods. The Scenario Test showed high levels of reliability. Internal consistency (Cronbach's alpha = 0.96; item-rest correlations = 0.58-0.82) and test-retest reliability (ICC = 0.98) were high. Agreement between judges in total scores was good, as indicated by the high inter- and intra-judge reliability (ICC = 0.86-1.00). Agreement in scores on the individual items was also good (square-weighted kappa values 0.61-0.92). The test demonstrated good levels of validity. A principal component analysis for categorical data identified two dimensions, interpreted as general communication and communicative creativity. Correlations with three other instruments measuring communication in aphasia, that is, Spontaneous Speech interview from the Aachen Aphasia Test (AAT), Amsterdam-Nijmegen Everyday Language Test (ANELT), and Communicative Effectiveness Index (CETI), were moderate to strong (0.50-0.85) suggesting good convergent validity. Group differences were observed between persons with aphasia and non-aphasic controls, as well as between persons with aphasia unable to use speech to convey information and those able to communicate verbally; this indicates good known-groups validity. The test was sensitive to changes in performance, measured over a period of 6 months. The data support the reliability and validity of the Scenario Test as an instrument for examining daily-life communication in aphasia. The test focuses on multimodal communication; its psychometric qualities enable future studies on the effect of Alternative and Augmentative Communication (AAC) training in aphasia.

  14. Development and Psychometric Testing of a Sexual Concerns Questionnaire for Kidney Transplant Recipients.

    PubMed

    Muehrer, Rebecca J; Lanuza, Dorothy M; Brown, Roger L; Djamali, Arjang

    2015-01-01

    This study describes the development and psychometric testing of the Sexual Concerns Questionnaire (SCQ) in kidney transplant (KTx) recipients. Construct validity was assessed using the Kroonenberg and Lewis exploratory/confirmatory procedure and testing hypothesized relationships with established questionnaires. Configural and weak invariance were examined across gender, dialysis history, relationship status, and transplant type. Reliability was assessed with Cronbach's alpha, composite reliability, and test-retest reliability. Factor analysis resulted in a 7-factor solution and suggests good model fit. Construct validity was also supported by the tests of hypothesized relationships. Configural and weak invariance were supported for all subgroups. Reliability of the SCQ was also supported. Findings indicate the SCQ is a valid and reliable measure of KTx recipients' sexual concerns.

  15. TEST-RETEST RELIABILITY OF THE CLOSED KINETIC CHAIN UPPER EXTREMITY STABILITY TEST (CKCUEST) IN ADOLESCENTS: RELIABILITY OF CKCUEST IN ADOLESCENTS.

    PubMed

    de Oliveira, Valéria M A; Pitangui, Ana C R; Nascimento, Vinícius Y S; da Silva, Hítalo A; Dos Passos, Muana H P; de Araújo, Rodrigo C

    2017-02-01

    The Closed Kinetic Chain Upper Extremity Stability Test (CKCUEST) has been proposed as an option to assess upper limb function and stability; however, there are few studies that support the use of this test in adolescents. The purpose of the present study was to investigate the intersession reliability and agreement of three CKCUEST scores in adolescents and establish clinimetric values for this test. Test-retest reliability. Twenty-five healthy adolescents of both sexes were evaluated. The subjects performed two CKCUEST with an interval of one week between the tests. An intraclass correlation coefficient (ICC 3,3 ) two-way mixed model with a 95% interval of confidence was utilized to determine intersession reliability. A Bland-Altman graph was plotted to analyze the agreement between assessments. The presence of systematic error was evaluated by a one-sample t test. The difference between the evaluation and reevaluation was observed using a paired-sample t test. The level of significance was set at 0.05. Standard error of measurements and minimum detectable changes were calculated. The intersession reliability of the average touches score, normalized score, and power score were 0.68, 0.68 and 0.87, the standard error of measurement were 2.17, 1.35 and 6.49, and the minimal detectable change was 6.01, 3.74 and 17.98, respectively. The presence of systematic error (p < 0.014), the significant difference between the measurements (p < 0.05), and the analysis of the Bland-Altman graph infer that CKCUEST is a discordant test with moderate to excellent reliability when used with adolescents. The CKCUEST is a measurement with moderate to excellent reliability for adolescents. 2b.

  16. Expanded experience with an intradermal skin test to predict for the presence or absence of carboplatin hypersensitivity.

    PubMed

    Markman, Maurie; Zanotti, Kristine; Peterson, Gertrude; Kulp, Barbara; Webster, Kenneth; Belinson, Jerome

    2003-12-15

    Carboplatin-associated hypersensitivity is increasingly recognized as a potentially serious toxicity when this agent is administered for more than six total cycles. Our group has used a predictive skin test in women with gynecologic cancers who have previously received more than six cumulative cycles of platinum-based chemotherapy. Thirty minutes before all subsequent carboplatin courses, a 0.02-mL aliquot from the solution prepared for treatment is injected intradermally. A positive test is considered to be a > or = 5-mm wheal, with a surrounding flare. From October 1998 through March 2003, 126 patients received a total of 717 carboplatin skin tests (median per patient, four tests; range, one to 54 tests). Of the 668 negative tests (93% of the total performed), 10 were associated with evidence of carboplatin hypersensitivity (1.5% false-negative rate; 95% CI, 0.6% to 2.4%), none of which were severe (eg, dyspnea, hypotension, cardiac/respiratory compromise). Of the 41 positive tests, the decision was made to not deliver the drug to 32 patients, although seven women ultimately underwent a future attempt at re-treatment with a platinum agent using a desensitization program. In seven episodes where patients received the carboplatin despite the finding of a positive test, six were associated with the development of symptoms of anaphylaxis (none severe). A negative carboplatin skin test seems to predict with reasonable reliability for the absence of a severe hypersensitivity reaction with the subsequent drug infusion. The implications of a positive test remain less certain, but limited experience with continued treatment suggests this approach must be undertaken with considerable caution.

  17. Combustor Operability and Performance Verification for HIFiRE Flight 2

    NASA Technical Reports Server (NTRS)

    Storch, Andrea M.; Bynum, Michael; Liu, Jiwen; Gruber, Mark

    2011-01-01

    As part of the Hypersonic International Flight Research Experimentation (HIFiRE) Direct-Connect Rig (HDCR) test and analysis activity, three-dimensional computational fluid dynamics (CFD) simulations were performed using two Reynolds-Averaged Navier Stokes solvers. Measurements obtained from ground testing in the NASA Langley Arc-Heated Scramjet Test Facility (AHSTF) were used to specify inflow conditions for the simulations and combustor data from four representative tests were used as benchmarks. Test cases at simulated flight enthalpies of Mach 5.84, 6.5, 7.5, and 8.0 were analyzed. Modeling parameters (e.g., turbulent Schmidt number and compressibility treatment) were tuned such that the CFD results closely matched the experimental results. The tuned modeling parameters were used to establish a standard practice in HIFiRE combustor analysis. Combustor performance and operating mode were examined and were found to meet or exceed the objectives of the HIFiRE Flight 2 experiment. In addition, the calibrated CFD tools were then applied to make predictions of combustor operation and performance for the flight configuration and to aid in understanding the impacts of ground and flight uncertainties on combustor operation.

  18. Validity and Reliability of Published Comprehensive Theory of Mind Tests for Normal Preschool Children: A Systematic Review.

    PubMed

    Ziatabar Ahmadi, Seyyede Zohreh; Jalaie, Shohreh; Ashayeri, Hassan

    2015-09-01

    Theory of mind (ToM) or mindreading is an aspect of social cognition that evaluates mental states and beliefs of oneself and others. Validity and reliability are very important criteria when evaluating standard tests; and without them, these tests are not usable. The aim of this study was to systematically review the validity and reliability of published English comprehensive ToM tests developed for normal preschool children. We searched MEDLINE (PubMed interface), Web of Science, Science direct, PsycINFO, and also evidence base Medicine (The Cochrane Library) databases from 1990 to June 2015. Search strategy was Latin transcription of 'Theory of Mind' AND test AND children. Also, we manually studied the reference lists of all final searched articles and carried out a search of their references. Inclusion criteria were as follows: Valid and reliable diagnostic ToM tests published from 1990 to June 2015 for normal preschool children; and exclusion criteria were as follows: the studies that only used ToM tests and single tasks (false belief tasks) for ToM assessment and/or had no description about structure, validity or reliability of their tests. METHODological quality of the selected articles was assessed using the Critical Appraisal Skills Programme (CASP). In primary searching, we found 1237 articles in total databases. After removing duplicates and applying all inclusion and exclusion criteria, we selected 11 tests for this systematic review. There were a few valid, reliable and comprehensive ToM tests for normal preschool children. However, we had limitations concerning the included articles. The defined ToM tests were different in populations, tasks, mode of presentations, scoring, mode of responses, times and other variables. Also, they had various validities and reliabilities. Therefore, it is recommended that the researchers and clinicians select the ToM tests according to their psychometric characteristics, validity and reliability.

  19. Validity and Reliability of Published Comprehensive Theory of Mind Tests for Normal Preschool Children: A Systematic Review

    PubMed Central

    Ziatabar Ahmadi, Seyyede Zohreh; Jalaie, Shohreh; Ashayeri, Hassan

    2015-01-01

    Objective: Theory of mind (ToM) or mindreading is an aspect of social cognition that evaluates mental states and beliefs of oneself and others. Validity and reliability are very important criteria when evaluating standard tests; and without them, these tests are not usable. The aim of this study was to systematically review the validity and reliability of published English comprehensive ToM tests developed for normal preschool children. Method: We searched MEDLINE (PubMed interface), Web of Science, Science direct, PsycINFO, and also evidence base Medicine (The Cochrane Library) databases from 1990 to June 2015. Search strategy was Latin transcription of ‘Theory of Mind’ AND test AND children. Also, we manually studied the reference lists of all final searched articles and carried out a search of their references. Inclusion criteria were as follows: Valid and reliable diagnostic ToM tests published from 1990 to June 2015 for normal preschool children; and exclusion criteria were as follows: the studies that only used ToM tests and single tasks (false belief tasks) for ToM assessment and/or had no description about structure, validity or reliability of their tests. Methodological quality of the selected articles was assessed using the Critical Appraisal Skills Programme (CASP). Result: In primary searching, we found 1237 articles in total databases. After removing duplicates and applying all inclusion and exclusion criteria, we selected 11 tests for this systematic review. Conclusion: There were a few valid, reliable and comprehensive ToM tests for normal preschool children. However, we had limitations concerning the included articles. The defined ToM tests were different in populations, tasks, mode of presentations, scoring, mode of responses, times and other variables. Also, they had various validities and reliabilities. Therefore, it is recommended that the researchers and clinicians select the ToM tests according to their psychometric characteristics, validity and reliability. PMID:27006666

  20. The development and reliability of a simple field based screening tool to assess core stability in athletes.

    PubMed

    O'Connor, S; McCaffrey, N; Whyte, E; Moran, K

    2016-07-01

    To adapt the trunk stability test to facilitate further sub-classification of higher levels of core stability in athletes for use as a screening tool. To establish the inter-tester and intra-tester reliability of this adapted core stability test. Reliability study. Collegiate athletic therapy facilities. Fifteen physically active male subjects (19.46 ± 0.63) free from any orthopaedic or neurological disorders were recruited from a convenience sample of collegiate students. The intraclass correlation coefficients (ICC) and 95% Confidence Intervals (CI) were computed to establish inter-tester and intra-tester reliability. Excellent ICC values were observed in the adapted core stability test for inter-tester reliability (0.97) and good to excellent intra-tester reliability (0.73-0.90). While the 95% CI were narrow for inter-tester reliability, Tester A and C 95% CI's were widely distributed compared to Tester B. The adapted core stability test developed in this study is a quick and simple field based test to administer that can further subdivide athletes with high levels of core stability. The test demonstrated high inter-tester and intra-tester reliability. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. HIFiRE-5 Flight Vehicle Design

    NASA Technical Reports Server (NTRS)

    Kimmel, Roger L.; Adamczak, David; Berger, Karen; Choudhari, Meelan

    2010-01-01

    The Hypersonic International Flight Research Experimentation (HIFiRE) program is a hypersonic flight test program executed by the Air Force Research Laboratories (AFRL) and Australian Defence Science and Technology Organization (DSTO). HIFiRE flight 5 is devoted to measuring transition on a three-dimensional body. This paper summarizes payload configuration, trajectory, vehicle stability limits and roughness tolerances. Results show that the proposed configuration is suitable for testing transition on a three-dimensional body. Transition is predicted to occur within the test window, and a design has been developed that will allow the vehicle to be manufactured within prescribed roughness tolerances

  2. Investigations of Control Surface Seals for Re-entry Vehicles

    NASA Technical Reports Server (NTRS)

    Dunlap, Patrick H., Jr.; Steinetz, Bruce M.; Curry, Donald M.; DeMange, Jeffrey J.; Rivers, H. Kevin; Hsu, Su-Yuen

    2002-01-01

    Re-entry vehicles generally require control surfaces (e.g., rudders, body flaps) to steer them during flight. Control surface seals are installed along hinge lines and where control surface edges move close to the vehicle body. These seals must operate at high temperatures and limit heat transfer to underlying structures to prevent them from overheating and causing possible loss of vehicle structural integrity. This paper presents results for thermal analyses and mechanical testing conducted on the baseline rudder/fin seal design for the X-38 re-entry vehicle. Exposure of the seals in a compressed state at the predicted peak seal temperature of 1900 F resulted in loss of seal resiliency. The vertical Inconel rudder/fin rub surface was re-designed to account for this loss of resiliency. Room temperature compression tests revealed that seal unit loads and contact pressures were below limits set to protect Shuttle thermal tiles on the horizontal sealing surface. The seals survived an ambient temperature 1000 cycle scrub test over sanded Shuttle tiles and were able to disengage and re-engage the tile edges during testing. Arc jet tests confirmed the need for seals in the rudder/fin gap location because a single seal caused a large temperature drop (delta T = 1710 F) in the gap.

  3. Inter-rater and intra-rater reliability of a movement control test in shoulder.

    PubMed

    Rajasekar, S; Bangera, Rakshith K; Sekaran, Padmanaban

    2017-07-01

    Movement faults are commonly observed in patients with musculoskeletal pain. The Kinetic Medial Rotation Test (KMRT) is a movement control test used to identify movement faults of the scapula and gleno-humeral joints during arm movement. Objective tests such as the KMRT need to be reliable and valid for the results to be applied across different clinical settings and patient populations. The primary objective of the present study was to determine the intra-rater and inter-rater reliability of KMRT in subjects with and without shoulder pain. Sixty subjects were included in this study based on specific inclusion and exclusion criteria. Two musculoskeletal physiotherapists with different levels of clinical experience performed the tests. The intra-rater reliability was tested in twenty asymptomatic subjects by a single assessor at two week intervals. An equal number of subjects with and without shoulder pain were tested by both the assessors to determine the inter-rater reliability. Both components of the KMRT, the Gleno- Humeral Anterior Translation (GHAT) and the Scapular Forward Tilt (SCFT) were tested. The Kappa values for inter-rater reliability of the GHAT and SCFT were K = 0.68 & K = 0.65 respectively in subjects with shoulder pain. In asymptomatic subjects, the inter-rater reliability of GHAT was K = 0.61 and SCFT was K = 0.85. Intra-rater reliability ranged from K = 0.66 for GHAT to K = 0.87 for SCFT. Our study found substantial agreement in inter-rater reliability of KMRT in subjects with shoulder pain, whereas substantial to near perfect agreement was found in intra-rater and inter-rater reliability of KMRT in subjects without shoulder pain. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Development and reliability of the rating of compensatory movements in upper limb prosthesis wearers during work-related tasks.

    PubMed

    van der Laan, Tallie M J; Postema, Sietke G; Reneman, Michiel F; Bongers, Raoul M; van der Sluis, Corry K

    2018-02-10

    Reliability study. Quantifying compensatory movements during work-related tasks may help to prevent musculoskeletal complaints in individuals with upper limb absence. (1) To develop a qualitative scoring system for rating compensatory shoulder and trunk movements in upper limb prosthesis wearers during the performance of functional capacity evaluation tests adjusted for use by 1-handed individuals (functional capacity evaluation-one handed [FCE-OH]); (2) to examine the interrater and intrarater reliability of the scoring system; and (3) to assess its feasibility. Movement patterns of 12 videotaped upper limb prosthesis wearers and 20 controls were analyzed. Compensatory movements were defined for each FCE-OH test, and a scoring system was developed, pilot tested, and adjusted. During reliability testing, 18 raters (12 FCE experts and 6 physiotherapists/gait analysts) scored videotapes of upper limb prosthesis wearers performing 4 FCE-OH tests 2 times (2 weeks apart). Agreement was expressed in % and kappa value. Feasibility (focus area's "acceptability", "demand," and "implementation") was determined by using a questionnaire. After 2 rounds of pilot testing and adjusting, reliability of a third version was tested. The interrater reliability for the first and second rating sessions were к = 0.54 (confidence interval [CI]: 0.52-0.57) and к = 0.64 (CI: 0.61-0.66), respectively. The intrarater reliability was к = 0.77 (CI: 0.72-0.82). The feasibility was good but could be improved by a training program. It seems possible to identify compensatory movements in upper limb prosthesis wearers during the performance of FCE-OH tests reliably by observation using the developed observational scoring system. Interrater reliability was satisfactory in most instances; intrarater reliability was good. Feasibility was established. Copyright © 2018 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  5. Comparison of liver fibrosis blood tests developed for HCV with new specific tests in HIV/HCV co-infection.

    PubMed

    Calès, Paul; Halfon, Philippe; Batisse, Dominique; Carrat, Fabrice; Perré, Philippe; Penaranda, Guillaume; Guyader, Dominique; d'Alteroche, Louis; Fouchard-Hubert, Isabelle; Michelet, Christian; Veillon, Pascal; Lambert, Jérôme; Weiss, Laurence; Salmon, Dominique; Cacoub, Patrice

    2010-08-01

    We compared 5 non-specific and 2 specific blood tests for liver fibrosis in HCV/HIV co-infection. Four hundred and sixty-seven patients were included into derivation (n=183) or validation (n=284) populations. Within these populations, the diagnostic target, significant fibrosis (Metavir F > or = 2), was found in 66% and 72% of the patients, respectively. Two new fibrosis tests, FibroMeter HICV and HICV test, were constructed in the derivation population. Unadjusted AUROCs in the derivation population were: APRI: 0.716, Fib-4: 0.722, Fibrotest: 0.778, Hepascore: 0.779, FibroMeter: 0.783, HICV test: 0.822, FibroMeter HICV: 0.828. AUROCs adjusted on classification and distribution of fibrosis stages in a reference population showed similar values in both populations. FibroMeter, FibroMeter HICV and HICV test had the highest correct classification rates in F0/1 and F3/4 (which account for high predictive values): 77-79% vs. 70-72% in the other tests (p=0.002). Reliable individual diagnosis based on predictive values > or = 90% distinguished three test categories: poorly reliable: Fib-4 (2.4% of patients), APRI (8.9%); moderately reliable: Fibrotest (25.4%), FibroMeter (26.6%), Hepascore (30.2%); acceptably reliable: HICV test (40.2%), FibroMeter HICV (45.6%) (p<10(-3) between tests). FibroMeter HICV classified all patients into four reliable diagnosis intervals (< or =F1, F1+/-1, > or =F1, > or =F2) with an overall accuracy of 93% vs. 79% (p<10(-3)) for a binary diagnosis of significant fibrosis. Tests designed for HCV infections are less effective in HIV/HCV infections. A specific test, like FibroMeter HICV, was the most interesting test for diagnostic accuracy, correct classification profile, and a reliable diagnosis. With reliable diagnosis intervals, liver biopsy can therefore be avoided in all patients. Copyright 2010 European Association for the Study of the Liver. Published by Elsevier B.V. All rights reserved.

  6. Fundamental Movement Skills Are More than Run, Throw and Catch: The Role of Stability Skills.

    PubMed

    Rudd, James R; Barnett, Lisa M; Butson, Michael L; Farrow, Damian; Berry, Jason; Polman, Remco C J

    2015-01-01

    In motor development literature fundamental movement skills are divided into three constructs: locomotive, object control and stability skills. Most fundamental movement skills research has focused on children's competency in locomotor and object control skills. The first aim of this study was to validate a test battery to assess the construct of stability skills, in children aged 6 to 10 (M age = 8.2, SD = 1.2). Secondly we assessed how the stability skills construct fitted into a model of fundamental movement skill. The Delphi method was used to select the stability skill battery. Confirmatory factor analysis (CFA) was used to assess if the skills loaded onto the same construct and a new model of FMS was developed using structural equation modelling. Three postural control tasks were selected (the log roll, rock and back support) because they had good face and content validity. These skills also demonstrated good predictive validity with gymnasts scoring significantly better than children without gymnastic training and children from a high SES school performing better than those from a mid and low SES schools and the mid SES children scored better than the low SES children (all p < .05). Inter rater reliability tests were excellent for all three skills (ICC = 0.81, 0.87, 0.87) as was test re-test reliability (ICC 0.87-0.95). CFA provided good construct validity, and structural equation modelling revealed stability skills to be an independent factor in an overall FMS model which included locomotor (r = .88), object control (r = .76) and stability skills (r = .81). This study provides a rationale for the inclusion of stability skills in FMS assessment. The stability skills could be used alongside other FMS assessment tools to provide a holistic assessment of children's fundamental movement skills.

  7. Validation of the French version of the Burn Specific Health Scale-Brief (BSHS-B) questionnaire.

    PubMed

    Gandolfi, S; Auquit-Auckbur, I; Panunzi, S; Mici, E; Grolleau, J-L; Chaput, B

    2016-11-01

    The Burn Specific Health Scale-Brief questionnaire is a widely validated tool for estimating the health related quality of life and for assessing the best multidisciplinary management of burn patients. The aim of this study was to translate the BSHS-B into French and to investigate its reliability and validity. According to the procedure proposed by the Scientific Advisory Committee of the Medical Outcomes Trust, the Burn Specific Health Scale-Brief (BSHS-B) was translated from the English version into French. In order to test the reliability of the French version of the BSHS-B, 53 burn patients French speakers completed the BSHS-B and SF-36 questionnaires from two to four years after burn. Ten of them have been re-tested at 6 months after the first evaluation. To evaluate clinical utility of the BSHS-F, internal consistency, construct validity (using SF-36) and stability in time were assessed using Cronbach's alpha statistic, Spearman rank test, and intra-class correlation coefficient respectively. The French version of the BSHS-B Cronbach's alpha coefficient was 0.93 and was >0.80 for all the sub-domains. French version of the BSHS-B and the SF-36 were positively correlated, all the associations were statistically significant (p<0.01). Intra-class correlation coefficients for test-retest ranged between 0.95 and 0.99 for the sub-domains. The intra-class correlation coefficient (ICC) for the total score was 0.98. The French version of the BSHS-B shows a robust rate of internal consistency, construct validity and stability in time, supporting its application in routine clinical practice as well as in international studies. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  8. ASSOCIATIONS BETWEEN THREE CLINICAL ASSESSMENT TOOLS FOR POSTURAL STABILITY

    PubMed Central

    Saxion, Casie E.; Cameron, Kenneth L.; Gerber, J. Parry

    2010-01-01

    Study Design: Clinical Measurement, Correlation, Reliability Objectives: To assess the relationship between the Single Leg Balance (SLB), modified Balance Error Scoring System (mBESS), and modified Star Excursion Balance (mSEBT) tests and secondarily to assess inter-rater and test-retest reliability of these tests. Background: Ankle sprains often result in chronic instability and dysfunction. Several clinical tests assess postural deficits as a potential cause of this dysfunction; however, limited information exists pertaining to the relationship that these tests have with one another. Methods: Two independent examiners measured the performance of 34 healthy participants completing the SLB Test, mBESS test, and mSEBT at two different time periods. The relationship between tests was assessed using the Pearson Correlation and Fisher's Exact Tests. Inter-rater and test-retest reliability were assessed using the intraclass correlation coefficient (ICC) and Kappa statistics. Results: A significant correlation (r = -0.35) was observed between the mSEBT and the mBESS. Fisher's Exact Test showed a significant association between the SLB Test and mBESS (P = .048), but no association between the SLB and mSEBT (P = 1.000). Inter-rater reliability was excellent for the mSEBT and fair for the mBESS (ICCs of .91 and .61 respectively). Excellent agreement was observed between raters for the SLB test (k = 1.00). Test-retest reliability was excellent for the mSEBT (ICC = 0.98) and fair for the mBESS (ICC = 0.74). There was poor test-retest agreement for the SLB test (k = .211). Conclusion: There was a significant relationship observed between the SLB Test, mBESS test, and mSEBT: however; strength of association measures showed limited overlap between these tests. This suggests that these tests are interrelated but may not assess equal components of postural stability. PMID:21589668

  9. Content Validity Index and Intra- and Inter-Rater Reliability of a New Muscle Strength/Endurance Test Battery for Swedish Soldiers

    PubMed Central

    Larsson, Helena; Tegern, Matthias; Monnier, Andreas; Skoglund, Jörgen; Helander, Charlotte; Persson, Emelie; Malm, Christer; Broman, Lisbet; Aasa, Ulrika

    2015-01-01

    The objective of this study was to examine the content validity of commonly used muscle performance tests in military personnel and to investigate the reliability of a proposed test battery. For the content validity investigation, thirty selected tests were those described in the literature and/or commonly used in the Nordic and North Atlantic Treaty Organization (NATO) countries. Nine selected experts rated, on a four-point Likert scale, the relevance of these tests in relation to five different work tasks: lifting, carrying equipment on the body or in the hands, climbing, and digging. Thereafter, a content validity index (CVI) was calculated for each work task. The result showed excellent CVI (≥0.78) for sixteen tests, which comprised of one or more of the military work tasks. Three of the tests; the functional lower-limb loading test (the Ranger test), dead-lift with kettlebells, and back extension, showed excellent content validity for four of the work tasks. For the development of a new muscle strength/endurance test battery, these three tests were further supplemented with two other tests, namely, the chins and side-bridge test. The inter-rater reliability was high (intraclass correlation coefficient, ICC2,1 0.99) for all five tests. The intra-rater reliability was good to high (ICC3,1 0.82–0.96) with an acceptable standard error of mean (SEM), except for the side-bridge test (SEM%>15). Thus, the final suggested test battery for a valid and reliable evaluation of soldiers’ muscle performance comprised the following four tests; the Ranger test, dead-lift with kettlebells, chins, and back extension test. The criterion-related validity of the test battery should be further evaluated for soldiers exposed to varying physical workload. PMID:26177030

  10. Reliability and Maintainability Analysis: A Conceptual Design Model

    DTIC Science & Technology

    1972-03-01

    Elements For a System I. Research ane Development A. Preliminary design and engineering B. Fabrication of test equipment C. Test operations D...reliability racquiro:wents, little, if any, modu larzation and auto- matic test features would be incorporated in the subsystem design, limited reliability...niaintaina~ility testing and monitoring would be conducted turing dev!qopmcnt, and little Quality Control effort, in the rell ability/’uaintainalility

  11. Kinematics of fast cervical rotations in persons with chronic neck pain: a cross-sectional and reliability study.

    PubMed

    Röijezon, Ulrik; Djupsjöbacka, Mats; Björklund, Martin; Häger-Ross, Charlotte; Grip, Helena; Liebermann, Dario G

    2010-09-27

    Assessment of sensorimotor function is useful for classification and treatment evaluation of neck pain disorders. Several studies have investigated various aspects of cervical motor functions. Most of these have involved slow or self-paced movements, while few have investigated fast cervical movements. Moreover, the reliability of assessment of fast cervical axial rotation has, to our knowledge, not been evaluated before. Cervical kinematics was assessed during fast axial head rotations in 118 women with chronic nonspecific neck pain (NS) and compared to 49 healthy controls (CON). The relationship between cervical kinematics and symptoms, self-rated functioning and fear of movement was evaluated in the NS group. A sub-sample of 16 NS and 16 CON was re-tested after one week to assess the reliability of kinematic variables. Six cervical kinematic variables were calculated: peak speed, range of movement, conjunct movements and three variables related to the shape of the speed profile. Together, peak speed and conjunct movements had a sensitivity of 76% and a specificity of 78% in discriminating between NS and CON, of which the major part could be attributed to peak speed (NS: 226 ± 88°/s and CON: 348 ± 92°/s, p < 0.01). Peak speed was slower in NS compared to healthy controls and even slower in NS with comorbidity of low-back pain. Associations were found between reduced peak speed and self-rated difficulties with running, performing head movements, car driving, sleeping and pain. Peak speed showed reasonably high reliability, while the reliability for conjunct movements was poor. Peak speed of fast cervical axial rotations is reduced in people with chronic neck pain, and even further reduced in subjects with concomitant low back pain. Fast cervical rotation test seems to be a reliable and valid tool for assessment of neck pain disorders on group level, while a rather large between subject variation and overlap between groups calls for caution in the interpretation of individual assessments.

  12. The use of self-report questions to examine the prevalence of musculoskeletal problems: a test-retest study.

    PubMed

    Gill, Tiffany K; Tucker, Graeme R; Avery, Jodie C; Shanahan, E Michael; Menz, Hylton B; Taylor, Anne W; Adams, Robert J; Hill, Catherine L

    2016-02-24

    Case definition has long been an issue for comparability of results obtained for musculoskeletal pain prevalence, however the test-retest reliability of questions used to determine joint pain prevalence has not been examined. The objective of this study was to determine question reliability and the impact of question wording, ordering and the time between questions on responses. A Computer Assisted Telephone Interviewing (CATI) survey was used to re-administer questions collected as part of a population-based longitudinal cohort study. On two different occasions questions were asked of the same sample of 203 community dwelling respondents (which were initially randomly selected) aged 18 years and over at two time points 14 to 27 days apart (average 15 days). Reliability of the questions was assessed using Cohen's kappa (κ) and intraclass correlation coefficient (ICC) and whether question wording and period effects existed was assessed using a crossover design. The self-reported prevalence of doctor diagnosed arthritis demonstrated excellent reliability (κ = 0.84 and κ = 0.79 for questionnaires 1 and 2 respectively). The reliability of questions relating to musculoskeletal pain and/or stiffness ranged from moderate to excellent for both types of questions, that is, those related to ever having joint pain on most days for at least a month (κ = 0.52 to κ = 0.95) and having pain and/or stiffness on most days for the last month (κ = 0.52 to κ = 0.90). However there was an effect of question wording on the results obtained for hand, foot and back pain and/or stiffness indicating that the area of pain may influence prevalence estimates. Joint pain and stiffness questions are reliable and can be used to determine prevalence. However, question wording and pain area may impact on estimates with issues such as pain perception and effect on activities playing a possible role in the recall of musculoskeletal pain.

  13. Intrarater and interrater reliability of the Anteromedial Reach Test in healthy participants

    PubMed Central

    Bent, Nicholas P; Rushton, Alison B; Wright, Chris C; Petherick, Emma-Jane; Batt, Mark E

    2014-01-01

    Background The Anteromedial Reach Test is a performance-based outcome measure for evaluating dynamic knee stability in patients with anterior cruciate ligament injury. No previously published study has adequately evaluated intrarater or interrater reliability of the Anteromedial Reach Test, so the purpose of this study was to assess these measurement properties in healthy participants prior to their investigation in patients with anterior cruciate ligament injury. Methods Two raters (A and B) tested 39 healthy university staff and students (20 men, 19 women). For the intrarater reliability investigation, rater A tested participants on three separate test occasions (days 1, 2, and 3) at the same time of day. For the interrater reliability investigation, raters A and B independently tested participants on the same test occasion (day 3). Results There was no significant systematic bias between test occasions or raters. Values of the intraclass correlation coefficient (2,1) were 0.96 for intrarater reliability of both the dominant leg and nondominant leg and 0.97 (dominant leg) and 0.98 (nondominant leg) for interrater reliability. Values for the standard error of measurement were 1.46 (dominant leg) and 1.62 (nondominant leg) for the intrarater investigation, and 1.26 (dominant leg) and 1.04 (nondominant leg) for the interrater investigation. At the 90% confidence level, the minimum detectable change was 3.8% and the error in an individual’s score at a given point in time was ±2.7%. Conclusion The Anteromedial Reach Test demonstrated excellent intrarater and interrater reliability in healthy participants. This provides a basis for future investigation of the measurement properties of the Anteromedial Reach Test in patients with anterior cruciate ligament injury. PMID:24648776

  14. Extending DFT-based genetic algorithms by atom-to-place re-assignment via perturbation theory: A systematic and unbiased approach to structures of mixed-metallic clusters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weigend, Florian, E-mail: florian.weigend@kit.edu

    2014-10-07

    Energy surfaces of metal clusters usually show a large variety of local minima. For homo-metallic species the energetically lowest can be found reliably with genetic algorithms, in combination with density functional theory without system-specific parameters. For mixed-metallic clusters this is much more difficult, as for a given arrangement of nuclei one has to find additionally the best of many possibilities of assigning different metal types to the individual positions. In the framework of electronic structure methods this second issue is treatable at comparably low cost at least for elements with similar atomic number by means of first-order perturbation theory, asmore » shown previously [F. Weigend, C. Schrodt, and R. Ahlrichs, J. Chem. Phys. 121, 10380 (2004)]. In the present contribution the extension of a genetic algorithm with the re-assignment of atom types to atom sites is proposed and tested for the search of the global minima of PtHf{sub 12} and [LaPb{sub 7}Bi{sub 7}]{sup 4−}. For both cases the (putative) global minimum is reliably found with the extended technique, which is not the case for the “pure” genetic algorithm.« less

  15. [Comparative measurement of urine specific gravity: reagent strips, refractometry and hydrometry].

    PubMed

    Costa, Christian Elías; Bettendorff, Carolina; Bupo, Sol; Ayuso, Sandra; Vallejo, Graciela

    2010-06-01

    The urine specific gravity is commonly used in clinical practice to measure the renal concentration/dilution ability. Measurement can be performed by three methods: hydrometry, refractometry and reagent strips. To assess the accuracy of different methods to measure urine specific gravity. We analyzed 156 consecutive urine samples of pediatric patients during April and May 2007. Urine specific gravity was measured by hydrometry (UD), refractometry (RE) and reagent strips (TR), simultaneously. Urine osmolarity was considered as the gold standard and was measured by freezing point depression. Correlation between different methods was calculated by simple linear regression. A positive and acceptable correlation was found with osmolarity for the RE as for the UD (r= 0.81 and r= 0.86, respectively). The reagent strips presented low correlation (r= 0.46). Also, we found good correlation between measurements obtained by UD and RE (r= 0.89). Measurements obtained by TR, however, had bad correlation when compared to UD (r= 0.46). Higher values of specific gravity were observed when measured with RE with respect to UD. Reagent strips are not reliable for measuring urine specific gravity and should not be used as an usual test. However, hydrometry and refractometry are acceptable alternatives for measuring urine specific gravity, as long as the same method is used for follow-up.

  16. Reliability of Computerized Neurocognitive Tests for Concussion Assessment: A Meta-Analysis.

    PubMed

    Farnsworth, James L; Dargo, Lucas; Ragan, Brian G; Kang, Minsoo

    2017-09-01

      Although widely used, computerized neurocognitive tests (CNTs) have been criticized because of low reliability and poor sensitivity. A systematic review was published summarizing the reliability of Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) scores; however, this was limited to a single CNT. Expansion of the previous review to include additional CNTs and a meta-analysis is needed. Therefore, our purpose was to analyze reliability data for CNTs using meta-analysis and examine moderating factors that may influence reliability.   A systematic literature search (key terms: reliability, computerized neurocognitive test, concussion) of electronic databases (MEDLINE, PubMed, Google Scholar, and SPORTDiscus) was conducted to identify relevant studies.   Studies were included if they met all of the following criteria: used a test-retest design, involved at least 1 CNT, provided sufficient statistical data to allow for effect-size calculation, and were published in English.   Two independent reviewers investigated each article to assess inclusion criteria. Eighteen studies involving 2674 participants were retained. Intraclass correlation coefficients were extracted to calculate effect sizes and determine overall reliability. The Fisher Z transformation adjusted for sampling error associated with averaging correlations. Moderator analyses were conducted to evaluate the effects of the length of the test-retest interval, intraclass correlation coefficient model selection, participant demographics, and study design on reliability. Heterogeneity was evaluated using the Cochran Q statistic.   The proportion of acceptable outcomes was greatest for the Axon Sports CogState Test (75%) and lowest for the ImPACT (25%). Moderator analyses indicated that the type of intraclass correlation coefficient model used significantly influenced effect-size estimates, accounting for 17% of the variation in reliability.   The Axon Sports CogState Test, which has a higher proportion of acceptable outcomes and shorter test duration relative to other CNTs, may be a reliable option; however, future studies are needed to compare the diagnostic accuracy of these instruments.

  17. Establishing the Test-Retest Reliability & Concurrent Validity for the Repeat Ice Skating Test (RIST) in Adolescent Male Ice Hockey Players

    ERIC Educational Resources Information Center

    Power, Allan; Faught, Brent E.; Przysucha, Eryk; McPherson, Moira; Montelpare, William

    2012-01-01

    In this study the authors examine the test-retest reliability and concurrent validity of the Repeat Ice Skating Test (RIST). This was an on-ice field anaerobic test that measured average peak power and was validated with 3 anaerobic lab tests: (a) vertical jump, (b) the Margaria-Kalamen stair test, and (c) the Wingate Anaerobic Test. The…

  18. Test-Retest Reliability of Computerized, Everyday Memory Measures and Traditional Memory Tests.

    ERIC Educational Resources Information Center

    Youngjohn, James R.; And Others

    Test-retest reliabilities and practice effect magnitudes were considered for nine computer-simulated tasks of everyday cognition and five traditional neuropsychological tests. The nine simulated everyday memory tests were from the Memory Assessment Clinic battery as follows: (1) simple reaction time while driving; (2) divided attention (driving…

  19. 34 CFR 668.144 - Application for test approval.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the comparability of scores on the current test to scores on the previous test, and data from validity... explanation of the methodology and procedures for measuring the reliability of the test; (ii) Evidence that different forms of the test, including, if applicable, short forms, are comparable in reliability; (iii...

  20. Reliability of the Client-Centeredness of Goal Setting (C-COGS) Scale in Acquired Brain Injury Rehabilitation.

    PubMed

    Doig, Emmah; Prescott, Sarah; Fleming, Jennifer; Cornwell, Petrea; Kuipers, Pim

    2016-01-01

    To examine the internal reliability and test-retest reliability of the Client-Centeredness of Goal Setting (C-COGS) scale. The C-COGS scale was administered to 42 participants with acquired brain injury after completion of multidisciplinary goal planning. Internal reliability of scale items was examined using item-partial total correlations and Cronbach's α coefficient. The scale was readministered within a 1-mo period to a subsample of 12 participants to examine test-retest reliability by calculating exact and close percentage agreement for each item. After examination of item-partial total correlations, test items were revised. The revised items demonstrated stronger internal consistency than the original items. Preliminary evaluation of test-retest reliability was fair, with an average exact percent agreement across all test items of 67%. Findings support the preliminary reliability of the C-COGS scale as a tool to evaluate and promote client-centered goal planning in brain injury rehabilitation. Copyright © 2016 by the American Occupational Therapy Association, Inc.

  1. The influence of various test plans on mission reliability. [for Shuttle Spacelab payloads

    NASA Technical Reports Server (NTRS)

    Stahle, C. V.; Gongloff, H. R.; Young, J. P.; Keegan, W. B.

    1977-01-01

    Methods have been developed for the evaluation of cost effective vibroacoustic test plans for Shuttle Spacelab payloads. The shock and vibration environments of components have been statistically represented, and statistical decision theory has been used to evaluate the cost effectiveness of five basic test plans with structural test options for two of the plans. Component, subassembly, and payload testing have been performed for each plan along with calculations of optimum test levels and expected costs. The tests have been ranked according to both minimizing expected project costs and vibroacoustic reliability. It was found that optimum costs may vary up to $6 million with the lowest plan eliminating component testing and maintaining flight vibration reliability via subassembly tests at high acoustic levels.

  2. Reliability and Normative Data for the Dynamic Visual Acuity Test for Vestibular Screening.

    PubMed

    Riska, Kristal M; Hall, Courtney D

    2016-06-01

    The purpose of this study was to determine reliability of computerized dynamic visual acuity (DVA) testing and to determine reference values for younger and older adults. A primary function of the vestibular system is to maintain gaze stability during head motion. The DVA test quantifies gaze stabilization with the head moving versus stationary. Commercially available computerized systems allow clinicians to incorporate DVA into their assessment; however, information regarding reliability and normative values of these systems is sparse. Forty-six healthy adults, grouped by age, with normal vestibular function were recruited. Each participant completed computerized DVA testing including static visual acuity, minimum perception time, and DVA using the NeuroCom inVision System. Testing was performed by two examiners in the same session and then repeated at a follow-up session 3 to 14 days later. Intraclass correlation coefficients (ICCs) were used to determine inter-rater and test-retest reliability. ICCs for inter-rater reliability ranged from 0.323 to 0.937 and from 0.434 to 0.909 for horizontal and vertical head movements, respectively. ICCs for test-retest reliability ranged from 0.154 to 0.856 and from 0.377 to 0.9062 for horizontal and vertical head movements, respectively. Overall, raw scores (left/right DVA and up/down DVA) were more reliable than DVA loss scores. Reliability of a commercially available DVA system has poor-to-fair reliability for DVA loss scores. The use of a convergence paradigm and not incorporating the forced choice paradigm may contribute to poor reliability.

  3. Reliability and Concurrent Validity of Dynamic Rotator Stability Test-A Cross Sectional study.

    PubMed

    Binoy Mathew, K V; Eapen, Charu; Kumar, P Senthil

    2012-01-01

    To find intra rater and inter rater reliability of Dynamic Rotator Stability Test (DRST) and to find concurrent validity of Dynamic Rotator Stability Test (DRST) with University of Pennsylvania Shoulder Score (PENN) Scale. 40 subjects of either gender between the age group of 18-70 with painful shoulder conditions of musculoskeletal origin was selected through convenient sampling. Tester 1 and tester 2 administered DRST and PENN scale randomly. In a subgroup of 20 subjects DRST was administered by both the testers to find the inter rater reliability. 180° Standard Universal Goniometer was used to take measurements. For intra-rater reliability, all the test variables were showing highly significant correlation (p=.94 - 1). For inter -rater, with tester 2, test variables like position, ROM, force, direction of abnormal translation, pain during the test, compensatory movement during test were found to be significant (p=.71-1).only some variables of DRST showed significant correlation with PENN scale (P=.320-.450). Dynamic Rotator Stability Test has good intra rater and moderate inter rater reliability. Concurrent validity of Dynamic Rotator Stability Test was found to be poor when compared to PENN Shoulder Score.

  4. Reliability of a Test Battery Designed for Quickly and Safely Assessing Diverse Indices of Neuromuscular Function

    NASA Technical Reports Server (NTRS)

    Spiering, Barry A.; Lee, Stuart M. C.; Mulavara, Ajitkumar P.; Bentley, Jason, R.; Buxton, Roxanne E.; Lawrence, Emily L.; Sinka, Joseph; Guilliams, Mark E.; Ploutz-Snyder, Lori L.; Bloomberg, Jacob J.

    2010-01-01

    Spaceflight affects nearly every physiological system. Spaceflight-induced alterations in physiological function translate to decrements in functional performance. Purpose: To develop a test battery for quickly and safely assessing diverse indices of neuromuscular performance. I. Quickly: Battery of tests can be completed in approx.30-40 min. II. Safely: a) No eccentric muscle actions or impact forces. b) Tests present little challenge to postural stability. III. Diverse indices: a) Strength: Excellent reliability (ICC = 0.99) b) Central activation: Very good reliability (ICC = 0.87) c) Power: Excellent reliability (ICC = 0.99) d) Endurance: Total work has excellent reliability (ICC = 0.99) e) Force steadiness: Poor reliability (ICC = 0.20 - 0.60) National

  5. Development of a High Intensity Focused Ultrasound (HIFU) Hydrophone System

    NASA Astrophysics Data System (ADS)

    Schafer, Mark E.; Gessert, James; Moore, Wayne

    2006-05-01

    Concomitant with the growing clinical use of High Intensity Focused Ultrasound (HIFU), there has been a need for reliable, economical and reproducible measurements of HIFU acoustic fields. A number of approaches have been proposed and investigated, most notably by Kaczkowski et al [Proc. 2003 IEEE Ultrasonics Symposium, 982-985]. We are developing a similar reflective scatterer approach, incorporating several novel features which improve the hydrophone's bandwidth, reliability, and reproducibility. For the scattering element, we have used a fused silica optical fiber with a polyamide protective coating. The receiver is designed as a segmented, truncated spherical structure with a 10cm radius; the scattering element is positioned at the center of the sphere. The receiver is made from 25 micron thick, biaxially stretched PVDF, with a Pt-Au electrode on the front surface. Each segment has its own high impedance, wideband preamplifier, and the signals from multiple segments are summed coherently. As an additional feature, the system is designed to pulse the PVDF elements so that the pulse-echo response can be used to align the fiber at the center. Initial tests of the system have demonstrated a receiver array sensitivity of -279 dB re 1 microVolt/Pa (before preamplification), with a scattering loss at the fiber of approximately 39dB, producing an effective sensitivity of -318 dB re 1 micro Volt/Pa. The addition of the closely coupled wideband preamplifiers boosts the signal to a range which is sufficient for the measurement of HIFU transducers. The effective bandwidth of the system exceeds 15MHz, through careful design and the use of PVDF as a sensor material. In order to test the system, a HIFU transducer in the 4.0MHz frequency range was tested at low output settings using a conventional PVDF membrane hydrophone. The prototype system was then used to characterize the same HIFU transducer at full power. The results showed good correlation between waveforms and cross-axis beam measurements, taking into account the additional shock losses at higher output settings.

  6. Reliability and validity of the Assessment of Daily Activity Performance (ADAP) in community-dwelling older women.

    PubMed

    de Vreede, Paul L; Samson, Monique M; van Meeteren, Nico L; Duursma, Sijmen A; Verhaar, Harald J

    2006-08-01

    The Assessment of Daily Activity Performance (ADAP) test was developed, and modeled after the Continuous-scale Physical Functional Performance (CS-PFP) test, to provide a quantitative assessment of older adults' physical functional performance. The aim of this study was to determine the intra-examiner reliability and construct validity of the ADAP in a community-living older population, and to identify the importance of tester experience. Forty-three community-dwelling, older women (mean age 75 yr +/-4.3) were randomized to the test-retest reliability study (n=19) or validation study (n=24). The intra-examiner reliability of an experienced (tester 1) and an inexperienced tester (tester 2) was assessed by comparing test and retest scores of 19 participants. Construct validity was assessed by comparing the ADAP scores of 24 participants with self-perceived function by the SF-36 Health Survey, muscle function tests, and the Timed Up and Go test (TUG). Tester 1 had good consistency and reliability scores (mean difference between test and retest scores (DIF), -1.05+/-1.99; 95% confidence interval (CI), -2.58 to 0.48; Cronbach's alpha (alpha) range, 0.83 to 0.98; intraclass correlation (ICC) range, 0.75 to 0.96; Limits of Agreement (LoA), -2.58 to 4.95). Tester 2 had lower reliability scores (DIF, -2.45+/-4.36; 95% CI, -5.56 to 0.67; alpha range, 0.53 to 0.94; ICC range, 0.36 to 0.90; LoA, -6.09 to 10.99), with a systematic difference between test and retest scores for the ADAP domain lower-body strength (-3.81; 95% CI, -6.09 to -1.54), ADAP correlated with SF-36 Physical Functioning scale (r=0.67), TUG test (r=-0.91) and with isometric knee extensor strength (r=0.80). The ADAP test is a reliable and valid instrument. Our results suggest that testers should practise using the test, to improve reliability, before applying it to clinical settings.

  7. THE NAVICULAR POSITION TEST – A RELIABLE MEASURE OF THE NAVICULAR BONE POSITION DURING REST AND LOADING

    PubMed Central

    Spörndly-Nees, Søren; Dåsberg, Brian; Nielsen, Rasmus Oestergaard; Boesen, Morten Ilum

    2011-01-01

    Background: Lower limb injuries are a large problem in athletes. However, there is a paucity of knowledge on the relationship between alignment of the medial longitudinal arch (MLA) of the foot and development of such injuries. A reliable and valid test to quantify foot type is needed to be able to investigate the relationship between arch type and injury likelihood. Feiss Line is a valid clinical measure of the MLA. However, no study has investigated the reliability of the test. Objectives: The purpose was to describe a modified version of the Feiss Line test and to determine the intra- and inter-tester reliability of this new foot alignment test. To emphasize the purpose of the modified test, the authors have named it The Navicular Position Test. Methods: Intra- and inter-tester reliability were evaluated of The Navicular Position Test with the use of ICC (interclass correlation coefficient) and Bland-Altman limits of agreement on 43 healthy, young, subjects. Results: Inter-tester mean difference -0.35 degrees [–1.32; 0.62] p = 0.47. Bland-Altman limits of agreement –6.55 to 5.85 degrees, ICC = 0.94. Intra-tester mean difference 0.47 degrees [–0.57; 1.50] p = 0.37. Bland-Altman limits of agreement –6.15 to 7.08 degrees, ICC = 0.91. Discussion: The present data support The Navicular Position Test as a reliable test of the navicular bone position during rest and loading measured in a simple test set-up. Conclusion: The Navicular Position Test was shown to have a high intraday-, intra- and inter-tester reliability. When cut off values to categorize the MLA into planus, rectus, or cavus feet, has been determined and presented, the test could be used in prospective observational studies investigating the role of the arch type on the development of various lower limb injuries. PMID:21904698

  8. Validity and reliability of a new ankle dorsiflexion measurement device.

    PubMed

    Gatt, Alfred; Chockalingam, Nachiappan

    2013-08-01

    The assessment of the maximum ankle dorsiflexion angle is an important clinical examination procedure. Evidence shows that the traditional goniometer is highly unreliable, and various designs of goniometers to measure the maximum ankle dorsiflexion angle rely on the application of a known force to obtain reliable results. Hence, an innovative ankle dorsiflexion measurement device was designed to make this measurement more reliable by holding the foot in a selected posture without the application of a known moment. To report on the comprehensive validity and reliability testing carried out on the new device. Following validity testing, four different trials to test reliability of the ankle dorsiflexion measurement device were performed. These trials included inter-rater and intra-rater testings with a controlled moment, intra-rater reliability testing with knees flexed and extended without a controlled moment, intra-rater testing with a patient population, and inter-rater reliability testing between four raters of varying experience without controlling moment. All raters were blinded. A series of trials to test intra-rater and inter-rater reliabilities. Intra-rater reliability intraclass correlation coefficient was 0.98 and inter-rater reliability intraclass correlation coefficient (2,1) was 0.953 with a controlled moment. With uncontrolled moment, very high reliability for intra-tester was also achieved (intraclass correlation coefficient = 0.94 with knees extended and intraclass correlation coefficient = 0.95 with knees flexed). For the trial investigating test-retest reliability with actual patients, intraclass correlation coefficient of 0.99 was obtained. In the trial investigating four different raters with uncontrolled moment, intraclass correlation coefficient of 0.91 was achieved. The new ankle dorsiflexion measurement device is a valid and reliable device for measuring ankle dorsiflexion in both healthy subjects and patients, with both controlled and uncontrolled moments, even by multiple raters of varying experience when the foot is dorsiflexed to its end of range of motion. An ankle dorsiflexion measuring device has been designed to increase the reliability of ankle dorsiflexion measurement and replace the traditional goniometer. While the majority of similar devices rely on application of a known moment to perform this measurement, it has been shown that this is not required with the new ankle dorsiflexion measurement device and, rather, foot posture should be taken into consideration as this affects the maximum ankle dorsiflexion angle.

  9. The Queensland high risk foot form (QHRFF) – is it a reliable and valid clinical research tool for foot disease?

    PubMed Central

    2014-01-01

    Background Foot disease complications, such as foot ulcers and infection, contribute to considerable morbidity and mortality. These complications are typically precipitated by “high-risk factors”, such as peripheral neuropathy and peripheral arterial disease. High-risk factors are more prevalent in specific “at risk” populations such as diabetes, kidney disease and cardiovascular disease. To the best of the authors’ knowledge a tool capturing multiple high-risk factors and foot disease complications in multiple at risk populations has yet to be tested. This study aimed to develop and test the validity and reliability of a Queensland High Risk Foot Form (QHRFF) tool. Methods The study was conducted in two phases. Phase one developed a QHRFF using an existing diabetes foot disease tool, literature searches, stakeholder groups and expert panel. Phase two tested the QHRFF for validity and reliability. Four clinicians, representing different levels of expertise, were recruited to test validity and reliability. Three cohorts of patients were recruited; one tested criterion measure reliability (n = 32), another tested criterion validity and inter-rater reliability (n = 43), and another tested intra-rater reliability (n = 19). Validity was determined using sensitivity, specificity and positive predictive values (PPV). Reliability was determined using Kappa, weighted Kappa and intra-class correlation (ICC) statistics. Results A QHRFF tool containing 46 items across seven domains was developed. Criterion measure reliability of at least moderate categories of agreement (Kappa > 0.4; ICC > 0.75) was seen in 91% (29 of 32) tested items. Criterion validity of at least moderate categories (PPV > 0.7) was seen in 83% (60 of 72) tested items. Inter- and intra-rater reliability of at least moderate categories (Kappa > 0.4; ICC > 0.75) was seen in 88% (84 of 96) and 87% (20 of 23) tested items respectively. Conclusions The QHRFF had acceptable validity and reliability across the majority of items; particularly items identifying relevant co-morbidities, high-risk factors and foot disease complications. Recommendations have been made to improve or remove identified weaker items for future QHRFF versions. Overall, the QHRFF possesses suitable practicality, validity and reliability to assess and capture relevant foot disease items across multiple at risk populations. PMID:24468080

  10. [European Portuguese EARS test battery adaptation].

    PubMed

    Alves, Marisa; Ramos, Daniela; Oliveira, Graça; Alves, Helena; Anderson, Ilona; Magalhães, Isabel; Martins, Jorge H; Simões, Margarida; Ferreira, Raquel; Fonseca, Rita; Andrade, Susana; Silva, Luís; Ribeiro, Carlos; Ferreira, Pedro Lopes

    2014-01-01

    The use of adequate assessment tools in health care is crucial for the management of care. The lack of specific tools in Portugal for assessing the performance of children who use cochlear implants motivated the translation and adaptation of the EARS (Evaluation of Auditory Responses to Speech) test battery into European Portuguese. This test battery is today one of the most commonly used by (re)habilitation teams of deaf children who use cochlear implants worldwide. The goal to be achieved with the validation of EARS was to provide (re)habilitation teams an instrument that enables: (i) monitoring the progress of individual (re)habilitation, (ii) managing a (re)habilitation program according to objective results, comparable between different (re)habilitation teams, (iii) obtaining data that can be compared with the results of international teams, and (iv) improving engagement and motivation of the family and other professionals from local teams. For the test battery translation and adaptation process, the adopted procedures were the following: (i) translation of the English version into European Portuguese by a professional translator, (ii) revision of the translation performed by an expert panel, including doctors, speech-language pathologists and audiologists, (iii) adaptation of the test stimuli by the team's speechlanguage pathologist, and (iv) further review by the expert panel. For each of the tests that belong to the EARS battery, the introduced adaptations and adjustments are presented, combining the characteristics and objectives of the original tests with the linguistic and cultural specificities of the Portuguese population. The difficulties that have been encountered during the translation and adaptation process and the adopted solutions are discussed. Comparisons are made with other versions of the EARS battery. We defend that the translation and the adaptation process followed for the EARS test battery into European Portuguese was correctly conducted, respecting the characteristics of the original instruments and adapting the test stimuli to the linguistic and cultural reality of the Portuguese population, thus meeting the goals that have been set.

  11. The test-retest reliability of the latent construct of executive function depends on whether tasks are represented as formative or reflective indicators.

    PubMed

    Willoughby, Michael T; Kuhn, Laura J; Blair, Clancy B; Samek, Anya; List, John A

    2017-10-01

    This study investigates the test-retest reliability of a battery of executive function (EF) tasks with a specific interest in testing whether the method that is used to create a battery-wide score would result in differences in the apparent test-retest reliability of children's performance. A total of 188 4-year-olds completed a battery of computerized EF tasks twice across a period of approximately two weeks. Two different approaches were used to create a score that indexed children's overall performance on the battery-i.e., (1) the mean score of all completed tasks and (2) a factor score estimate which used confirmatory factor analysis (CFA). Pearson and intra-class correlations were used to investigate the test-retest reliability of individual EF tasks, as well as an overall battery score. Consistent with previous studies, the test-retest reliability of individual tasks was modest (rs ≈ .60). The test-retest reliability of the overall battery scores differed depending on the scoring approach (r mean  = .72; r factor_ score  = .99). It is concluded that the children's performance on individual EF tasks exhibit modest levels of test-retest reliability. This underscores the importance of administering multiple tasks and aggregating performance across these tasks in order to improve precision of measurement. However, the specific strategy that is used has a large impact on the apparent test-retest reliability of the overall score. These results replicate our earlier findings and provide additional cautionary evidence against the routine use of factor analytic approaches for representing individual performance across a battery of EF tasks.

  12. Test-retest reliability of a balance testing protocol with external perturbations in young healthy adults.

    PubMed

    Robbins, Shawn M; Caplan, Ryan M; Aponte, Daniel I; St-Onge, Nancy

    2017-10-01

    External perturbations are utilized to challenge balance and mimic realistic balance threats in patient populations. The reliability of such protocols has not been established. The purpose was to examine test-retest reliability of balance testing with external perturbations. Healthy adults (n=34; mean age 23 years) underwent balance testing over two visits. Participants completed ten balance conditions in which the following parameters were combined: perturbation or non-perturbation, single or double leg, and eyes open or closed. Three trials were collected for each condition. Data were collected on a force plate and external perturbations were applied by translating the plate. Force plate center of pressure (CoP) data were summarized using 13 different CoP measures. Test-retest reliability was examined using intraclass correlation coefficients (ICC) and Bland-Altman plots. CoP measures of total speed and excursion in both anterior-posterior and medial-lateral directions generally had acceptable ICC values for perturbation conditions (ICC=0.46 to 0.87); however, many other CoP measures (e.g. range, area of ellipse) had unacceptable test-retest reliability (ICC<0.70). Improved CoP measures were present on the second visit indicating a potential learning effect. Non-perturbation conditions generally produced more reliable CoP measures than perturbation conditions during double leg standing, but not single leg standing. Therefore, changes to balance testing protocols that include external perturbations should be made to improve test-retest reliability and diminish learning including more extensive participant training and increasing the number of trials. CoP measures that consider all data points (e.g. total speed) are more reliable than those that only consider a few data points. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. A REVIEW OF SINGLE SPECIES TOXICITY TESTS: ARE THE TESTS RELIABLE PREDICTORS OF AQUATIC ECOSYSTEM COMMUNITY RESPONSES?

    EPA Science Inventory

    This document provides a comprehensive review to evaluate the reliability of indicator species toxicity test results in predicting aquatic ecosystem impacts, also called the ecological relevance of laboratory single species toxicity tests.

  14. Assessment of a condition-specific quality-of-life measure for patients with developmentally absent teeth: validity and reliability testing.

    PubMed

    Akram, A J; Ireland, A J; Postlethwaite, K C; Sandy, J R; Jerreat, A S

    2013-11-01

    This article describes the process of validity and reliability testing of a condition-specific quality-of-life measure for patients with hypodontia presenting for orthodontic treatment. The development of the instrument is described in a previous article. Royal Devon and Exeter NHS Foundation Trust & Musgrove Park Hospital, Taunton. The child perception questionnaire was used as a standard against which to test criterion validity. The Bland and Altman method was used to check agreement between the two questionnaires. Construct validity was tested using principal component analysis on the four sections of the questionnaire. Test-retest reliability was tested using intraclass correlation coefficient and Bland and Altman method. Cronbach's alpha was used to test internal consistency reliability. Overall the questionnaire showed good reliability, criterion and construct validity. This together with previous evidence of good face and content validity suggests that the instrument may prove useful in clinical practice and further research. This study has demonstrated that the newly developed condition-specific quality-of-life questionnaire is both valid and reliable for use in young patients with hypodontia. © 2013 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.

  15. Reliability of Measurement of Glenohumeral Internal Rotation, External Rotation, and Total Arc of Motion in 3 Test Positions

    PubMed Central

    Kevern, Mark A.; Beecher, Michael; Rao, Smita

    2014-01-01

    Context: Athletes who participate in throwing and racket sports consistently demonstrate adaptive changes in glenohumeral-joint internal and external rotation in the dominant arm. Measurements of these motions have demonstrated excellent intrarater and poor interrater reliability. Objective: To determine intrarater reliability, interrater reliability, and standard error of measurement for shoulder internal rotation, external rotation, and total arc of motion using an inclinometer in 3 testing procedures in National Collegiate Athletic Association Division I baseball and softball athletes. Design: Cross-sectional study. Setting: Athletic department. Patients or Other Participants Thirty-eight players participated in the study. Shoulder internal rotation, external rotation, and total arc of motion were measured by 2 investigators in 3 test positions. The standard supine position was compared with a side-lying test position, as well as a supine test position without examiner overpressure. Results: Excellent intrarater reliability was noted for all 3 test positions and ranges of motion, with intraclass correlation coefficient values ranging from 0.93 to 0.99. Results for interrater reliability were less favorable. Reliability for internal rotation was highest in the side-lying position (0.68) and reliability for external rotation and total arc was highest in the supine-without-overpressure position (0.774 and 0.713, respectively). The supine-with-overpressure position yielded the lowest interrater reliability results in all positions. The side-lying position had the most consistent results, with very little variation among intraclass correlation coefficient values for the various test positions. Conclusions: The results of our study clearly indicate that the side-lying test procedure is of equal or greater value than the traditional supine-with-overpressure method. PMID:25188316

  16. Test-retest reliability of the assessment of postural stability in typically developing children and in hearing impaired children.

    PubMed

    De Kegel, A; Dhooge, I; Cambier, D; Baetens, T; Palmans, T; Van Waelvelde, H

    2011-04-01

    The purpose of this study was to establish test-retest reliability of centre of pressure (COP) measurements obtained by an AccuGait portable forceplate (ACG), mean COG sway velocity measured by a Basic Balance Master (BBM) and clinical balance tests in children with and without balance difficulties. 49 typically developing children and 23 hearing impaired children, with a higher risk for stability problems, between 6 and 12 years of age participated. Each child performed the modified Clinical Test of Sensory Interaction on Balance (mCTSIB), Unilateral Stance (US) and Tandem Stance on ACG, mCTSIB and US on BBM and clinical balance tests: one-leg standing, balance beam walking and one-leg hopping. All subjects completed 2 test sessions on 2 different days in the same week assessed by the same examiner. Among COP measurements obtained by the ACG, mean sway velocity was the most reliable parameter with all ICCs higher than 0.72. The standard deviation (SD) of sway velocity, sway area, SD of anterior-posterior and SD of medio-lateral COP data showed moderate to excellent reliability with ICCs between 0.55 and 0.96 but some caution must be taken into account in some conditions. BBM is less reliable but clinical balance tests are as reliable as ACG. Hearing impaired children exhibited better relative reliability (ICC) and comparable absolute reliability (SEM) for most balance parameters compared to typically developing children. Reliable information regarding postural stability of typically developing children and hearing impaired children may be obtained utilizing COP measurements generated by an AccuGait system and clinical balance tests. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. Reliability, validity and description of timed performance of the Jebsen-Taylor Test in patients with muscular dystrophies.

    PubMed

    Artilheiro, Mariana Cunha; Fávero, Francis Meire; Caromano, Fátima Aparecida; Oliveira, Acary de Souza Bulle; Carvas, Nelson; Voos, Mariana Callil; Sá, Cristina Dos Santos Cardoso de

    2017-12-08

    The Jebsen-Taylor Test evaluates upper limb function by measuring timed performance on everyday activities. The test is used to assess and monitor the progression of patients with Parkinson disease, cerebral palsy, stroke and brain injury. To analyze the reliability, internal consistency and validity of the Jebsen-Taylor Test in people with Muscular Dystrophy and to describe and classify upper limb timed performance of people with Muscular Dystrophy. Fifty patients with Muscular Dystrophy were assessed. Non-dominant and dominant upper limb performances on the Jebsen-Taylor Test were filmed. Two raters evaluated timed performance for inter-rater reliability analysis. Test-retest reliability was investigated by using intraclass correlation coefficients. Internal consistency was assessed using the Cronbach alpha. Construct validity was conducted by comparing the Jebsen-Taylor Test with the Performance of Upper Limb. The internal consistency of Jebsen-Taylor Test was good (Cronbach's α=0.98). A very high inter-rater reliability (0.903-0.999), except for writing with an Intraclass correlation coefficient of 0.772-1.000. Strong correlations between the Jebsen-Taylor Test and the Performance of Upper Limb Module were found (rho=-0.712). The Jebsen-Taylor Test is a reliable and valid measure of timed performance for people with Muscular Dystrophy. Copyright © 2017 Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia. Publicado por Elsevier Editora Ltda. All rights reserved.

  18. Reliability of a science admission test (HAM-Nat) at Hamburg medical school.

    PubMed

    Hissbach, Johanna; Klusmann, Dietrich; Hampe, Wolfgang

    2011-01-01

    The University Hospital in Hamburg (UKE) started to develop a test of knowledge in natural sciences for admission to medical school in 2005 (Hamburger Auswahlverfahren für Medizinische Studiengänge, Naturwissenschaftsteil, HAM-Nat). This study is a step towards establishing the HAM-Nat. We are investigating parallel forms reliability, the effect of a crash course in chemistry on test results, and correlations of HAM-Nat test results with a test of scientific reasoning (similar to a subtest of the "Test for Medical Studies", TMS). 316 first-year students participated in the study in 2007. They completed different versions of the HAM-Nat test which consisted of items that had already been used (HN2006) and new items (HN2007). Four weeks later half of the participants were tested on the HN2007 version of the HAM-Nat again, while the other half completed the test of scientific reasoning. Within this four week interval students were offered a five day chemistry course. Parallel forms reliability for four different test versions ranged from r(tt)=.53 to r(tt)=.67. The retest reliabilities of the HN2007 halves were r(tt)=.54 and r(tt )=.61. Correlations of the two HAM-Nat versions with the test of scientific reasoning were r=.34 und r=.21. The crash course in chemistry had no effect on HAM-Nat scores. The results suggest that further versions of the test of natural sciences will not easily conform to the standards of internal consistency, parallel-forms reliability and retest reliability. Much care has to be taken in order to assemble items which could be used interchangeably for the construction of new test versions. The test of scientific reasoning and the HAM-Nat are tapping different constructs. Participation in a chemistry course did not improve students' achievement, probably because the content of the course was not coordinated with the test and many students lacked of motivation to do well in the second test.

  19. Reliability of a science admission test (HAM-Nat) at Hamburg medical school

    PubMed Central

    Hissbach, Johanna; Klusmann, Dietrich; Hampe, Wolfgang

    2011-01-01

    Objective: The University Hospital in Hamburg (UKE) started to develop a test of knowledge in natural sciences for admission to medical school in 2005 (Hamburger Auswahlverfahren für Medizinische Studiengänge, Naturwissenschaftsteil, HAM-Nat). This study is a step towards establishing the HAM-Nat. We are investigating parallel forms reliability, the effect of a crash course in chemistry on test results, and correlations of HAM-Nat test results with a test of scientific reasoning (similar to a subtest of the "Test for Medical Studies", TMS). Methods: 316 first-year students participated in the study in 2007. They completed different versions of the HAM-Nat test which consisted of items that had already been used (HN2006) and new items (HN2007). Four weeks later half of the participants were tested on the HN2007 version of the HAM-Nat again, while the other half completed the test of scientific reasoning. Within this four week interval students were offered a five day chemistry course. Results: Parallel forms reliability for four different test versions ranged from rtt=.53 to rtt=.67. The retest reliabilities of the HN2007 halves were rtt=.54 and rtt =.61. Correlations of the two HAM-Nat versions with the test of scientific reasoning were r=.34 und r=.21. The crash course in chemistry had no effect on HAM-Nat scores. Conclusions: The results suggest that further versions of the test of natural sciences will not easily conform to the standards of internal consistency, parallel-forms reliability and retest reliability. Much care has to be taken in order to assemble items which could be used interchangeably for the construction of new test versions. The test of scientific reasoning and the HAM-Nat are tapping different constructs. Participation in a chemistry course did not improve students’ achievement, probably because the content of the course was not coordinated with the test and many students lacked of motivation to do well in the second test. PMID:21866246

  20. Psychometric properties of the Children’s Revised Impact of Events Scale (CRIES) with Bangladeshi children and adolescents

    PubMed Central

    Deeba, Farah; Prvan, Tania

    2014-01-01

    Identification of possible cases suffering post-traumatic stress disorder (PTSD) is important, especially in developing countries where traumatic events are typically prevalent. The Children’s Revised Impact of Events Scale is a reliable and valid measure that has two brief versions (13 items and 8 items) to assess reactions to traumatic events among young people. The current study evaluated the psychometric properties of both versions of the CRIES in a sample of 1,342 children and adolescents aged 9–17 years (M = 12.3 years, SD = 2.12) recruited from six districts of Bangladesh. A sub-group of 120 children from four schools was re-tested on the measures within 3.5 weeks. Confirmatory factor analysis supported factor structures similar to those found in other studies for both versions of the CRIES. Multiple group confirmatory factor analysis showed gender and age-group differences within the sample, supporting established age and gender differences in prevalence of PTSD symptoms. Analyses also indicated moderate to excellent internal consistency and test-retest reliability and clear discriminant and convergent validity. These data support use of both the CRIES-13 and CRIES-8 to provide quick and psychometrically sound assessment of symptoms of PTSD among children and adolescents from Bangla-speaking communities. PMID:25237597

  1. Psychometric properties of the hearing handicap questionnaire: a Kannada (South-Indian) translation.

    PubMed

    Thammaiah, Spoorthi; Manchaiah, Vinaya; Easwar, Vijayalakshmi; Krishna, Rajalakshmi; McPherson, Bradley

    2017-03-01

    To assess the psychometric properties of the Hearing Handicap Questionnaire (HHQ) in Kannada (a South-Indian language) among adults with hearing loss. The study involved a cross-sectional survey design. Participants provided demographic details and completed the Kannada and English (original) version of the HHQ questionnaire. To evaluate test-retest reliability, ∼50% of the participants completed the Kannada version for the second time after 15 days. The sample comprised 103 adults with hearing loss recruited from local audiology clinics. Exploratory factor analysis indicated a one-factor structure, which explained 71% of the variance in Kannada-HHQ scores. The internal consistency measured with Cronbach's alpha was 0.96. The test-retest reliability correlations of the Kannada version with the English and with the same Kannada version re-administered after 15 days were 0.96 and 0.91, respectively. Convergent validity of the scale was confirmed by significant correlations with the Participation Scale and the Assessment of Quality of Life scales. Discriminant validity was found to be low as all the Kannada-HHQ questions were highly correlated with each other (r> 0.60). No floor and ceiling effects were identified. The psychometric properties of the Kannada-HHQ scale are considered to be adequate for clinical or research use.

  2. The shape of novel objects contributes to shared impressions.

    PubMed

    Kurosu, Aaron; Todorov, Alexander

    2017-11-01

    How do people share impressions of novel objects, and is this even possible? We tested whether the shape of novel 3-D objects can lead to similar impressions across people. To do this, we introduced a technique for manipulating highly complex shapes and measured four types of evaluative impressions (approachable, dangerous, beautiful, likable). Because relatively little is understood regarding how people form impressions of novel objects, we first sought to confirm the reliability of this behavior by examining how similar impressions are for an individual asked to re-evaluate the stimuli (i.e., impression consistency). To situate the magnitude of reliability, we compared novel objects to faces-familiar and extensively studied stimuli. Impression consistency was always present for both types of stimuli and comparable across all evaluations. Second, and more importantly, we tested how similar impressions are across people (i.e., impression consensus). Impression consensus was always present for faces, but not always for novel objects. In Study 2 we examined a greater diversity of shapes and replicated the findings of Study 1 for novel objects. The findings suggest that impression consensus for novel objects only emerges when certain types of shapes and evaluations map together. When such mapping is possible, impressions are isomorphic with the parametrized shapes.

  3. Evaluation of two imaging techniques: near-infrared transillumination and dental radiographs for the detection of early approximal enamel caries.

    PubMed

    Maia, A M A; Karlsson, L; Margulis, W; Gomes, A S L

    2011-10-01

    The aim of this paper was to evaluate a transillumination (TI) system using near-infrared (NIR) light and bitewing radiographs for the detection of early approximal enamel caries lesions. Mesiodistal sections of teeth (n = 14) were cut with various thicknesses from 1.5 mm to 4.75 mm. Both sides of each section were included, 17 approximal surfaces with natural enamel caries and 11 surfaces considered intact. The approximal surfaces were illuminated by NIR light and X-ray. Captured images were analysed by two calibrated specialists in radiology, and re-analysed after 6 months using stereomicroscope images as a gold standard. The interexaminer reliability (Kappa test statistic) for the NIR TI technique showed moderate agreement on first (0.55) and second (0.48) evaluation, and low agreement for bitewing radiographs on first (0.26) and second (0.32) evaluation. In terms of accuracy, the sensitivity for the NIR TI system was 0.88 and the specificity was 0.72. For the bitewing radiographs the sensitivity ranged from 0.35 to 0.53 and the specificity ranged from 0.50 to 0.72. In the same samples and conditions tested, NIR TI images showed reliability and the enamel caries surfaces were better identified than on dental radiographs.

  4. Evaluation of two imaging techniques: near-infrared transillumination and dental radiographs for the detection of early approximal enamel caries

    PubMed Central

    Maia, A M A; Karlsson, L; Margulis, W; Gomes, A S L

    2011-01-01

    Objectives The aim of this paper was to evaluate a transillumination (TI) system using near-infrared (NIR) light and bitewing radiographs for the detection of early approximal enamel caries lesions. Methods Mesiodistal sections of teeth (n = 14) were cut with various thicknesses from 1.5 mm to 4.75 mm. Both sides of each section were included, 17 approximal surfaces with natural enamel caries and 11 surfaces considered intact. The approximal surfaces were illuminated by NIR light and X-ray. Captured images were analysed by two calibrated specialists in radiology, and re-analysed after 6 months using stereomicroscope images as a gold standard. Results The interexaminer reliability (Kappa test statistic) for the NIR TI technique showed moderate agreement on first (0.55) and second (0.48) evaluation, and low agreement for bitewing radiographs on first (0.26) and second (0.32) evaluation. In terms of accuracy, the sensitivity for the NIR TI system was 0.88 and the specificity was 0.72. For the bitewing radiographs the sensitivity ranged from 0.35 to 0.53 and the specificity ranged from 0.50 to 0.72. Conclusion In the same samples and conditions tested, NIR TI images showed reliability and the enamel caries surfaces were better identified than on dental radiographs. PMID:21960400

  5. Space Shuttle Propulsion System Reliability

    NASA Technical Reports Server (NTRS)

    Welzyn, Ken; VanHooser, Katherine; Moore, Dennis; Wood, David

    2011-01-01

    This session includes the following sessions: (1) External Tank (ET) System Reliability and Lessons, (2) Space Shuttle Main Engine (SSME), Reliability Validated by a Million Seconds of Testing, (3) Reusable Solid Rocket Motor (RSRM) Reliability via Process Control, and (4) Solid Rocket Booster (SRB) Reliability via Acceptance and Testing.

  6. Evaluating the test-retest reliability of symptom indices associated with the ImPACT post-concussion symptom scale (PCSS).

    PubMed

    Merritt, Victoria C; Bradson, Megan L; Meyer, Jessica E; Arnett, Peter A

    2018-05-01

    The Immediate Post-Concussion Assessment and Cognitive Testing (ImPACT) is a commonly used tool in sports concussion assessment. While test-retest reliabilities have been established for the ImPACT cognitive composites, few studies have evaluated the psychometric properties of the ImPACT's Post-Concussion Symptom Scale (PCSS). The purpose of this study was to establish the test-retest reliability of symptom indices associated with the PCSS. Participants included 38 undergraduate students (50.0% male) who underwent neuropsychological testing as part of their participation in their psychology department's research subject pool. The majority of the participants were Caucasian (94.7%) and had no history of concussion (73.7%). All participants completed the ImPACT at two time points, approximately 6 weeks apart. The PCSS was the main outcome measure, and eight symptom indices were calculated (a total symptom score, three symptom summary indices, and four symptom clusters). Pearson correlations (r) and intraclass correlation coefficients (ICCs) were computed as measures of test-retest reliability. Overall, reliabilities ranged from low to high (r = .44 to .80; ICC = .44 to .77). The cognitive symptom cluster exhibited the highest test-retest reliability (r = .80, ICC = .77), followed by the positive symptom total (PST) index, an indicator of the total number of symptoms endorsed (r = .71, ICC = .69). In contrast, the commonly used total symptom score showed lower test-retest reliability (r = .67, ICC = .62). Paired-samples t tests revealed no significant differences between test and retest for any of the symptom variables (all p > .01). Finally, reliable change indices (RCI) were computed to determine whether differences observed between test and retest represented clinically significant change. RCI values were provided for each symptom index at the 80%, 90%, and 95% confidence intervals. These results suggest that evaluating additional symptom indices beyond the total symptom score from the PCSS is beneficial. Findings from this study can be applied to athlete samples to assess reliable change in symptoms following concussion.

  7. Impact of relationships between test and training animals and among training animals on reliability of genomic prediction.

    PubMed

    Wu, X; Lund, M S; Sun, D; Zhang, Q; Su, G

    2015-10-01

    One of the factors affecting the reliability of genomic prediction is the relationship among the animals of interest. This study investigated the reliability of genomic prediction in various scenarios with regard to the relationship between test and training animals, and among animals within the training data set. Different training data sets were generated from EuroGenomics data and a group of Nordic Holstein bulls (born in 2005 and afterwards) as a common test data set. Genomic breeding values were predicted using a genomic best linear unbiased prediction model and a Bayesian mixture model. The results showed that a closer relationship between test and training animals led to a higher reliability of genomic predictions for the test animals, while a closer relationship among training animals resulted in a lower reliability. In addition, the Bayesian mixture model in general led to a slightly higher reliability of genomic prediction, especially for the scenario of distant relationships between training and test animals. Therefore, to prevent a decrease in reliability, constant updates of the training population with animals from more recent generations are required. Moreover, a training population consisting of less-related animals is favourable for reliability of genomic prediction. © 2015 Blackwell Verlag GmbH.

  8. Integrating Formal Methods and Testing 2002

    NASA Technical Reports Server (NTRS)

    Cukic, Bojan

    2002-01-01

    Traditionally, qualitative program verification methodologies and program testing are studied in separate research communities. None of them alone is powerful and practical enough to provide sufficient confidence in ultra-high reliability assessment when used exclusively. Significant advances can be made by accounting not only tho formal verification and program testing. but also the impact of many other standard V&V techniques, in a unified software reliability assessment framework. The first year of this research resulted in the statistical framework that, given the assumptions on the success of the qualitative V&V and QA procedures, significantly reduces the amount of testing needed to confidently assess reliability at so-called high and ultra-high levels (10-4 or higher). The coming years shall address the methodologies to realistically estimate the impacts of various V&V techniques to system reliability and include the impact of operational risk to reliability assessment. Combine formal correctness verification, process and product metrics, and other standard qualitative software assurance methods with statistical testing with the aim of gaining higher confidence in software reliability assessment for high-assurance applications. B) Quantify the impact of these methods on software reliability. C) Demonstrate that accounting for the effectiveness of these methods reduces the number of tests needed to attain certain confidence level. D) Quantify and justify the reliability estimate for systems developed using various methods.

  9. Reliability of the Test of Integrated Language and Literacy Skills (TILLS).

    PubMed

    Mailend, Marja-Liisa; Plante, Elena; Anderson, Michele A; Applegate, E Brooks; Nelson, Nickola W

    2016-07-01

    As new standardized tests become commercially available, it is critical that clinicians have access to the information about a test's psychometric properties, including aspects of reliability. The purpose of the three studies reported in this article was to investigate the reliability of a new test, the Test of Integrated Language and Literacy Skills (TILLS), with consideration of both internal and external sources of measurement error. The TILLS was administered to children aged 6;0-18;11 years. The participants varied in terms of their language and literacy skills and included children with typical language development as well as those diagnosed with language or learning disability. The sample of children also varied in terms of their racial and socioeconomic backgrounds. Study 1 (N = 1056) assessed the internal consistency of TILLS calculating the coefficient omega for each subtest. Study 2 (N = 103) and Study 3 (N = 39) used the intra-class correlation coefficients to report on test-retest and inter-rater reliability respectively. The results indicate strong internal consistency and inter-rater reliability for all subtests of TILLS. The test-retest reliability was strong for all but one subtest, for which the intra-class correlation coefficient was in the acceptable range. This article provides clinicians with essential scientific information that supports the internal and external reliability of a new test of oral and written language skills, the TILLS. Information about reliability is critical for guiding the selection of an appropriate diagnostic tool amongst a number of options. © 2016 Royal College of Speech and Language Therapists.

  10. Test-Retest Reliability of the Short-Form Survivor Unmet Needs Survey.

    PubMed

    Taylor, Karen; Bulsara, Max; Monterosso, Leanne

    2018-01-01

    Reliable and valid needs assessment measures are important assessment tools in cancer survivorship care. A new 30-item short-form version of the Survivor Unmet Needs Survey (SF-SUNS) was developed and validated with cancer survivors, including hematology cancer survivors; however, test-retest reliability has not been established. The objective of this study was to assess the test-retest reliability of the SF-SUNS with a cohort of lymphoma survivors ( n = 40). Test-retest reliability of the SF-SUNS was conducted at two time points: baseline (time 1) and 5 days later (time 2). Test-retest data were collected from lymphoma cancer survivors ( n = 40) in a large tertiary cancer center in Western Australia. Intraclass correlation analyses compared data at time 1 (baseline) and time 2 (5 days later). Cronbach's alpha analyses were performed to assess the internal consistency at both time points. The majority (23/30, 77%) of items achieved test-retest reliability scores 0.45-0.74 (fair to good). A high degree of overall internal consistency was demonstrated (time 1 = 0.92, time 2 = 0.95), with scores 0.65-0.94 across subscales for both time points. Mixed test-retest reliability of the SF-SUNS was established. Our results indicate the SF-SUNS is responsive to the changing needs of lymphoma cancer survivors. Routine use of cancer survivorship specific needs-based assessments is required in oncology care today. Nurses are well placed to administer these assessments and provide tailored information and resources. Further assessment of test-retest reliability in hematology and other cancer cohorts is warranted.

  11. Gearbox Reliability Collaborative Phase 3 Gearbox 3 Test

    DOE Data Explorer

    Keller, Jonathan (ORCID:0000000177243885)

    2016-12-28

    The GRC uses a combined gearbox testing, modeling, and analysis approach disseminating data and results to the industry and facilitating improvement of gearbox reliability. This test data describes the tests of GRC gearbox 3 in the National Wind Technology Center dynamometer and documents any modifications to the original test plan. It serves as a guide to interpret the publicly released data sets with brief analyses to illustrate the data. TDMS viewer and Solidworks software required to view data files. The National Renewable Energy Laboratory (NREL) Gearbox Reliability Collaborative (GRC) was established by the U.S. Department of Energy in 2006; its key goal is to understand the root causes of premature gearbox failures and improve their reliability.

  12. Gearbox Reliability Collaborative Phase 3 Gearbox 2 Test

    DOE Data Explorer

    Keller, Jonathan; Robb, Wallen

    2016-05-12

    The National Renewable Energy Laboratory (NREL) Gearbox Reliability Collaborative (GRC) was established by the U.S. Department of Energy in 2006; its key goal is to understand the root causes of premature gearbox failures and improve their reliability. The GRC uses a combined gearbox testing, modeling, and analysis approach disseminating data and results to the industry and facilitating improvement of gearbox reliability. This test data describes the tests of GRC gearbox 2 in the National Wind Technology Center dynamometer and documents any modifications to the original test plan. It serves as a guide to interpret the publicly released data sets with brief analyses to illustrate the data. TDMS viewer and Solidworks software required to view data files.

  13. System reliability analysis through corona testing

    NASA Technical Reports Server (NTRS)

    Lalli, V. R.; Mueller, L. A.; Koutnik, E. A.

    1975-01-01

    In the Reliability and Quality Engineering Test Laboratory at the NASA Lewis Research Center a nondestructive, corona-vacuum test facility for testing power system components was developed using commercially available hardware. The test facility was developed to simulate operating temperature and vacuum while monitoring corona discharges with residual gases. This facility is being used to test various high voltage power system components.

  14. The precision and torque production of common hip adductor squeeze tests used in elite football.

    PubMed

    Light, N; Thorborg, K

    2016-11-01

    Decreased hip adductor strength is a known risk factor for groin injury in footballers, with clinicians testing adductor strength in various positions and using different protocols. Understanding how reliable and how much torque different adductor squeeze tests produce will facilitate choosing the most appropriate method for future testing. In this study, the reliability and torque production of three common adductor squeeze tests were investigated. Test-retest reliability and cross-sectional comparison. Twenty elite level footballers (16-33 years) without previous or current groin pain were recruited. Relative and absolute test-retest reliability, and torque production of three adductor squeeze tests (long-lever in abduction, short-lever in adduction and short-lever in abduction/external rotation) were investigated. Each participant performed a series of isometric strength tests measured by hand-held dynamometry in each position, on two test days separated by two weeks. No systematic variation was seen for any of the tests when using the mean of three measures (ICC=0.84-0.97, MDC%=6.6-19.5). The smallest variation was observed when taking the mean of three repetitions in the long-lever position (ICC=0.97, MDC%=6.6). The long-lever test also yielded the highest mean torque values, which were 69% and 11% higher than the short-lever in adduction test and short-lever in abduction/external rotation test respectively (p<0.001). All three tests described in this study are reliable methods of measuring adductor squeeze strength. However, the test performed in the long-lever position seems the most promising as it displays high test-retest precision and the highest adductor torque production. Copyright © 2015 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  15. Wind Power Reliability Research | Wind | NREL

    Science.gov Websites

    Reliability Collaborative fact sheet. Wind Turbine Blade Reliability Wind turbine blade failures are an extremely rare occurrence, but when they do happen, the results can be catastrophic. For this reason, blade manufacturers require tests of blade properties, static mechanical tests, and fatigue tests to certify wind

  16. Test-Retest Reliability of a Survey to Measure Transport-Related Physical Activity in Adults

    ERIC Educational Resources Information Center

    Badland, Hannah; Schofield, Grant

    2006-01-01

    The present research details test-retest reliability of a newly developed, telephone-administered TPA survey for adults. This instrument examines barriers, perceptions, and current travel behaviors to place of work/study and local convenience shops. Demonstrated test-retest reliability of the Active Friendly Environments-Transport-Related Physical…

  17. Reliability and Validity of Information about Student Achievement: Comparing Large-Scale and Classroom Testing Contexts

    ERIC Educational Resources Information Center

    Cizek, Gregory J.

    2009-01-01

    Reliability and validity are two characteristics that must be considered whenever information about student achievement is collected. However, those characteristics--and the methods for evaluating them--differ in large-scale testing and classroom testing contexts. This article presents the distinctions between reliability and validity in the two…

  18. Estimating Measures of Pass-Fail Reliability from Parallel Half-Tests.

    ERIC Educational Resources Information Center

    Woodruff, David J.; Sawyer, Richard L.

    Two methods for estimating measures of pass-fail reliability are derived, by which both theta and kappa may be estimated from a single test administration. The methods require only a single test administration and are computationally simple. Both are based on the Spearman-Brown formula for estimating stepped-up reliability. The non-distributional…

  19. The "Good, Bad and Ugly" pin site grading system: A reliable and memorable method for documenting and monitoring ring fixator pin sites.

    PubMed

    Clint, S A; Eastwood, D M; Chasseaud, M; Calder, P R; Marsh, D R

    2010-02-01

    Although there is much in the literature regarding pin site infections, there is no accepted, validated method for documenting their state. We present a system for reliably labelling pin sites on any ring fixator construct and an easy-to-remember grading system to document the state of each pin site. Each site is graded in terms of erythema, pain and discharge to give a 3-point scale, named "Good", "Bad" and "Ugly" for ease of recall. This system was tested for intra- and inter-observer reproducibility. 15 patients undergoing elective limb reconstruction were recruited. A total of 218 pin sites were independently scored by 2 examiners. 82 were then re-examined later by the same examiners. 514 pin sites were felt to be "Good", 80 "Bad" and 6 "Ugly". The reproducibility of the system was found to be excellent. We feel our system gives a quick, reliable and reproducible method to monitor individual pin sites and their response to treatment. Crown Copyright 2009. Published by Elsevier Ltd. All rights reserved.

  20. The retest reliability of the six-minute walk test in patients referred to a cardiac rehabilitation programme.

    PubMed

    Hanson, Lisa C; McBurney, Helen; Taylor, Nicholas F

    2012-03-01

    The purpose of this paper was to determine if the Six-minute Walk Test (6MWT) was a reliable exercise test for patients referred to cardiac rehabilitation when up to three tests were performed and to determine if test scores differed according to between-test time interval. Thirty adults aged 63 ± 7.9 years referred to cardiac rehabilitation participated in a repeated measures reliability trial. Participants completed three 6MWTs within a one-week period. Participants were randomly allocated to one of three groups: on the first day, Group A completed three walks, Group B completed two walks and Group C completed one walk. Relative reliability was expressed in a ratio (ICC(2,1) ), and absolute reliability was expressed in metres (95% confidence intervals) for group and individuals. The 6MWT demonstrated a high level of relative reliability (intraclass correlation coefficients [ICC] = 0.94) across the three walks. There was no statistically significant difference between the test scores of the three groups. However, there was an increase in distance walked from the first to the second to the third 6MWT. Absolute reliability indicated that a change of at least 44 m would be required to be interpreted as true change in a group, and at least 95 m to be interpreted as true change in an individual with 95% confidence. Three 6MWTs completed in relatively short timeframes were not sufficient for reliable results as there was an increase in the distance walked, and relatively large increases in distances would be required to be interpreted as change. It did not make any difference whether the tests were all completed on one day or over one week. This study highlighted problems that may arise when relying on reliability coefficients alone to interpret reliability. These results suggest that the 6MWT may not have sufficient reliability to be a suitable test to evaluate exercise tolerance in patients referred to cardiac rehabilitation. Copyright © 2011 John Wiley & Sons, Ltd.

  1. The development and validation of the Questionnaire on Anticipated Discrimination (QUAD).

    PubMed

    Gabbidon, Jheanell; Brohan, Elaine; Clement, Sarah; Henderson, R Claire; Thornicroft, Graham

    2013-11-07

    The anticipation of mental health-related discrimination is common amongst people with mental health problems and can have serious adverse effects. This study aimed to develop and validate a measure assessing the extent to which people with mental health problems anticipate that they will personally experience discrimination across a range of contexts. The items and format for the Questionnaire on Anticipated Discrimination (QUAD) were developed from previous versions of the Discrimination and Stigma Scale (DISC), focus groups and cognitive debriefing interviews which were used to further refine the content and format. The resulting provisional version of the QUAD was completed by 117 service users in an online survey and reliability, validity, precision and acceptability were assessed. A final version of the scale was agreed and analyses re-run using the online survey data and data from an independent sample to report the psychometric properties of the finalised scale. The provisional version of the QUAD had 17 items, good internal consistency (alpha = 0.86) and adequate convergent validity as supported by the significant positive correlations with the Stigma Scale (SS) (r = 0.40, p < 0.001) and the Internalised Stigma of Mental Illness Scale (ISMI) (r = 0.40, p < 0.001). Three items were removed due to low endorsements, high inter-correlation or conceptual concerns. The finalised 14 item QUAD had good internal consistency (alpha = 0.86), good test re-test reliability (ρ(c) = 0.81) and adequate convergent validity: correlations with the ISMI (r = 0.45, p < 0.001) and with the SS (r = 0.39, p < 0.001). Reading ease scores indicated good acceptability for general adult populations. Cross-replication in an independent sample further indicated good internal consistency (alpha = 0.88), adequate convergent validity and revealed two factors summarised by institutions/services and interpersonal/professional relationships. The QUAD expanded upon previous versions of the DISC. It is a reliable, valid and acceptable measure which can be used to identify key life areas in which people may personally anticipate discrimination, and an overall tendency to anticipate discrimination. It may also be useful in planning interventions aimed at reducing the stigma of mental illness.

  2. Interrater reliability of schizoaffective disorder compared with schizophrenia, bipolar disorder, and unipolar depression - A systematic review and meta-analysis.

    PubMed

    Santelmann, Hanno; Franklin, Jeremy; Bußhoff, Jana; Baethge, Christopher

    2016-10-01

    Schizoaffective disorder is a common diagnosis in clinical practice but its nosological status has been subject to debate ever since it was conceptualized. Although it is key that diagnostic reliability is sufficient, schizoaffective disorder has been reported to have low interrater reliability. Evidence based on systematic review and meta-analysis methods, however, is lacking. Using a highly sensitive literature search in Medline, Embase, and PsycInfo we identified studies measuring the interrater reliability of schizoaffective disorder in comparison to schizophrenia, bipolar disorder, and unipolar disorder. Out of 4126 records screened we included 25 studies reporting on 7912 patients diagnosed by different raters. The interrater reliability of schizoaffective disorder was moderate (meta-analytic estimate of Cohen's kappa 0.57 [95% CI: 0.41-0.73]), and substantially lower than that of its main differential diagnoses (difference in kappa between 0.22 and 0.19). Although there was considerable heterogeneity, analyses revealed that the interrater reliability of schizoaffective disorder was consistently lower in the overwhelming majority of studies. The results remained robust in subgroup and sensitivity analyses (e.g., diagnostic manual used) as well as in meta-regressions (e.g., publication year) and analyses of publication bias. Clinically, the results highlight the particular importance of diagnostic re-evaluation in patients diagnosed with schizoaffective disorder. They also quantify a widely held clinical impression of lower interrater reliability and agree with earlier meta-analysis reporting low test-retest reliability. Copyright © 2016. Published by Elsevier B.V.

  3. RE-ENTERING BUILDING FOLLOWING CHEMICAL ATTACK: MEASURING THE EFFECTIVENESS OF SURFACE DECONTAMINATION

    EPA Science Inventory

    Prior to re-entering a building following a chemical attack, decontamination and testing must be conducted to determine whether toxic agents have been eliminated or reduced to safe levels. Building contents must also be decontaminated and tested or destroyed. Recent incidents i...

  4. Efficient Round-Trip Time Optimization for Replica-Exchange Enveloping Distribution Sampling (RE-EDS).

    PubMed

    Sidler, Dominik; Cristòfol-Clough, Michael; Riniker, Sereina

    2017-06-13

    Replica-exchange enveloping distribution sampling (RE-EDS) allows the efficient estimation of free-energy differences between multiple end-states from a single molecular dynamics (MD) simulation. In EDS, a reference state is sampled, which can be tuned by two types of parameters, i.e., smoothness parameters(s) and energy offsets, such that all end-states are sufficiently sampled. However, the choice of these parameters is not trivial. Replica exchange (RE) or parallel tempering is a widely applied technique to enhance sampling. By combining EDS with the RE technique, the parameter choice problem could be simplified and the challenge shifted toward an optimal distribution of the replicas in the smoothness-parameter space. The choice of a certain replica distribution can alter the sampling efficiency significantly. In this work, global round-trip time optimization (GRTO) algorithms are tested for the use in RE-EDS simulations. In addition, a local round-trip time optimization (LRTO) algorithm is proposed for systems with slowly adapting environments, where a reliable estimate for the round-trip time is challenging to obtain. The optimization algorithms were applied to RE-EDS simulations of a system of nine small-molecule inhibitors of phenylethanolamine N-methyltransferase (PNMT). The energy offsets were determined using our recently proposed parallel energy-offset (PEOE) estimation scheme. While the multistate GRTO algorithm yielded the best replica distribution for the ligands in water, the multistate LRTO algorithm was found to be the method of choice for the ligands in complex with PNMT. With this, the 36 alchemical free-energy differences between the nine ligands were calculated successfully from a single RE-EDS simulation 10 ns in length. Thus, RE-EDS presents an efficient method for the estimation of relative binding free energies.

  5. Assessment Tools for Use in Patients with Ménière Disease: An Update.

    PubMed

    Ciorba, Andrea; Skarżyński, Piotr Henryk; Corazzi, Virginia; Bianchini, Chiara; Aimoni, Claudia; Hatzopoulos, Stavros

    2017-12-28

    A number of electrophysiological tests have been proposed for the initial diagnostic assessment or for the follow-up phase of patients affected by Ménière disease. The most common are: (i) vestibular evoked myogenic potentials (VEMPs); (ii) electrocochleography (ECochG); and (iii) otoacoustic emissions (OAEs). This paper presents the latest clinical developments with these 3 testing modalities. The PubMed, Embase, and Cinahl databases were searched from 2006 to December 2016. Full-text articles were obtained in cases where the title, abstract, or key words suggested that the study may be eligible for this review. The medical subject heading (MeSH) terms included the following: Ménière, hearing threshold, vestibule, otoacoustic emissions, inner ear, ECochG, VEMPs. There were 368 identified papers, out of which 87 were eligible for inclusion. Overall the data in the literature are still limited and the recommended procedures have not reached an international consensus. From the available data, one can conclude that none of the electrophysiological tests could be considered as pathognomonic, for the diagnosis of Ménière disease: presently, the tests could be mostly used in a supportive role to the clinical diagnosis. Hopefully, in the future, improved technology in electrophysiological testing could contribute to the development of better strategies for the diagnosis of Ménière disease.

  6. Test-retest reliability of lower limb isokinetic endurance in COPD: A comparison of angular velocities

    PubMed Central

    Ribeiro, Fernanda; Lépine, Pierre-Alexis; Garceau-Bolduc, Corine; Coats, Valérie; Allard, Étienne; Maltais, François; Saey, Didier

    2015-01-01

    Background The purpose of this study was to determine and compare the test-retest reliability of quadriceps isokinetic endurance testing at two knee angular velocities in patients with chronic obstructive pulmonary disease (COPD). Methods After one familiarization session, 14 patients with moderate to severe COPD (mean age 65±4 years; forced expiratory volume in 1 second (FEV1) 55%±18% predicted) performed two quadriceps isokinetic endurance tests on two separate occasions within a 5–7-day interval. Quadriceps isokinetic endurance tests consisted of 30 maximal knee extensions at angular velocities of 90° and 180° per second, performed in random order. Test-retest reliability was assessed for peak torque, muscle endurance, work slope, work fatigue index, and changes in FEV1 for dyspnea and leg fatigue from rest to the end of the test. The intraclass correlation coefficient, minimal detectable change, and limits of agreement were calculated. Results High test-retest reliability was identified for peak torque and muscle total work at both velocities. Work fatigue index was considered reliable at 90° per second but not at 180° per second. A lower reliability was identified for dyspnea and leg fatigue scores at both angular velocities. Conclusion Despite a limited sample size, our findings support the use of a 30-maximal repetition isokinetic muscle testing procedure at angular velocities of 90° and 180° per second in patients with moderate to severe COPD. Endurance measurement (total isokinetic work) at 90° per second was highly reliable, with a minimal detectable change at the 95% confidence level of 10%. Peak torque and fatigue index could also be assessed reliably at 90° per second. Evaluation of dyspnea and leg fatigue using the modified Borg scale of perceived exertion was poorly reliable and its clinical usefulness is questionable. These results should be useful in the design and interpretation of future interventions aimed at improving muscle endurance in COPD. PMID:26124656

  7. Effect of a patient training video on visual field test reliability

    PubMed Central

    Sherafat, H; Spry, P G D; Waldock, A; Sparrow, J M; Diamond, J P

    2003-01-01

    Aims: To evaluate the effect of a visual field test educational video on the reliability of the first automated visual field test of new patients. Methods: A prospective, randomised, controlled trial of an educational video on visual field test reliability of patients referred to the hospital eye service for suspected glaucoma was undertaken. Patients were randomised to either watch an educational video or a control group with no video. The video group was shown a 4.5 minute audiovisual presentation to familiarise them with the various aspects of visual field examination with particular emphasis on sources of unreliability. Reliability was determined using standard criteria of fixation loss rate less than 20%, false positive responses less than 33%, and false negative responses less than 33%. Results: 244 patients were recruited; 112 in the video group and 132 in the control group with no significant between group difference in age, sex, and density of field defects. A significant improvement in reliability (p=0.015) was observed in the group exposed to the video with 85 (75.9%) patients having reliable results compared to 81 (61.4%) in the control group. The difference was not significant for the right (first tested) eye with 93 (83.0%) of the visual fields reliable in the video group compared to 106 (80.0%) in the control group (p = 0.583), but was significant for the left (second tested) eye with 97 (86.6 %) of the video group reliable versus 97 (73.5%) of the control group (p = 0.011). Conclusions: The use of a brief, audiovisual patient information guide on taking the visual field test produced an improvement in patient reliability for individuals tested for the first time. In this trial the use of the video had most of its impact by reducing the number of unreliable fields from the second tested eye. PMID:12543740

  8. Effect of a patient training video on visual field test reliability.

    PubMed

    Sherafat, H; Spry, P G D; Waldock, A; Sparrow, J M; Diamond, J P

    2003-02-01

    To evaluate the effect of a visual field test educational video on the reliability of the first automated visual field test of new patients. A prospective, randomised, controlled trial of an educational video on visual field test reliability of patients referred to the hospital eye service for suspected glaucoma was undertaken. Patients were randomised to either watch an educational video or a control group with no video. The video group was shown a 4.5 minute audiovisual presentation to familiarize them with the various aspects of visual field examination with particular emphasis on sources of unreliability. Reliability was determined using standard criteria of fixation loss rate less than 20%, false positive responses less than 33%, and false negative responses less than 33%. 244 patients were recruited; 112 in the video group and 132 in the control group with no significant between group difference in age, sex, and density of field defects. A significant improvement in reliability (p=0.015) was observed in the group exposed to the video with 85 (75.9%) patients having reliable results compared to 81 (61.4%) in the control group. The difference was not significant for the right (first tested) eye with 93 (83.0%) of the visual fields reliable in the video group compared to 106 (80.0%) in the control group (p = 0.583), but was significant for the left (second tested) eye with 97 (86.6 %) of the video group reliable versus 97 (73.5%) of the control group (p = 0.011). The use of a brief, audiovisual patient information guide on taking the visual field test produced an improvement in patient reliability for individuals tested for the first time. In this trial the use of the video had most of its impact by reducing the number of unreliable fields from the second tested eye.

  9. 42 CFR 493.1254 - Standard: Maintenance and function checks.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... ensures equipment, instrument, and test system performance that is necessary for accurate and reliable... equipment, instrument, and test system performance that is necessary for accurate and reliable test results...

  10. Reliability generalization: a viable key for establishing validity generalization

    NASA Technical Reports Server (NTRS)

    Kennedy, R. S.; Turnage, J. J.

    1991-01-01

    Even with radical restriction of range, reliability coefficients from 10 studies gave an average interstudy value of .74, suggesting constancy of reliability over diverse experiments. A value from a new test can help index reliability of tests not previously studied.

  11. Functional performance testing of the hip in athletes: a systematic review for reliability and validity.

    PubMed

    Kivlan, Benjamin R; Martin, Robroy L

    2012-08-01

    The purpose of this study was to systematically review the literature for functional performance tests with evidence of reliability and validity that could be used for a young, athletic population with hip dysfunction. A search of PubMed and SPORTDiscus databases were performed to identify movement, balance, hop/jump, or agility functional performance tests from the current peer-reviewed literature used to assess function of the hip in young, athletic subjects. The single-leg stance, deep squat, single-leg squat, and star excursion balance tests (SEBT) demonstrated evidence of validity and normative data for score interpretation. The single-leg stance test and SEBT have evidence of validity with association to hip abductor function. The deep squat test demonstrated evidence as a functional performance test for evaluating femoroacetabular impingement. Hop/Jump tests and agility tests have no reported evidence of reliability or validity in a population of subjects with hip pathology. Use of functional performance tests in the assessment of hip dysfunction has not been well established in the current literature. Diminished squat depth and provocation of pain during the single-leg balance test have been associated with patients diagnosed with FAI and gluteal tendinopathy, respectively. The SEBT and single-leg squat tests provided evidence of convergent validity through an analysis of kinematics and muscle function in normal subjects. Reliability of functional performance tests have not been established on patients with hip dysfunction. Further study is needed to establish reliability and validity of functional performance tests that can be used in a young, athletic population with hip dysfunction. 2b (Systematic Review of Literature).

  12. Intra- and interrater reliability of the 'lumbar-locked thoracic rotation test' in competitive swimmers ages 10 through 18 years.

    PubMed

    Feijen, Stef; Kuppens, Kevin; Tate, Angela; Baert, Isabel; Struyf, Thomas; Struyf, Filip

    2018-04-17

    Measuring thoracic spine mobility can be of interest to competitive swimmers as it has been associated with shoulder girdle function and scapular position in subjects with and without shoulder pain. At present, no reliability data of thoracic spine mobility measurements are available in the swimming population. This study aims to evaluate the within-session intra- and interrater reliability of the "lumbar-locked rotation test" for thoracic spine rotation in competitive swimmers aged 10 to 18 years. This reliability study is part of a larger prospective cohort study investigating potential risk factors for the development of shoulder pain in competitive swimmers. Within-session, intra- and inter-rater reliability. Competitive swimming clubs in Belgium. 21 competitive swimmers. Intra- and inter-rater reliability of the lumbar-locked thoracic rotation test. Intraclass correlation coefficients (ICCs) ranged from 0.91 (95% CI 0.78 to 0.96) to 0.96 (0.89-0.98) for intra-rater reliability. Results for inter-rater reliability ranged from 0.89 (0.72-0.95) to 0.86 (0.65-0.94) respectively for right and left thoracic rotation. Results suggest good to excellent reliability of the lumbar-locked thoracic rotation test, indicating this test can be used reliably in clinical practice. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. Reliability of ultrasound thickness measurement of the abdominal muscles during clinical isometric endurance tests.

    PubMed

    ShahAli, Shabnam; Arab, Amir Massoud; Talebian, Saeed; Ebrahimi, Esmaeil; Bahmani, Andia; Karimi, Noureddin; Nabavi, Hoda

    2015-07-01

    The study was designed to evaluate the intra-examiner reliability of ultrasound (US) thickness measurement of abdominal muscles activity when supine lying and during two isometric endurance tests in subjects with and without Low back pain (LBP). A total of 19 women (9 with LBP, 10 without LBP) participated in the study. Within-day reliability of the US thickness measurements at supine lying and the two isometric endurance tests were assessed in all subjects. The intra-class correlation coefficient (ICC) was used to assess the relative reliability of thickness measurement. The standard error of measurement (SEM), minimal detectable change (MDC) and the coefficient of variation (CV) were used to evaluate the absolute reliability. Results indicated high ICC scores (0.73-0.99) and also small SEM and MDC scores for within-day reliability assessment. The Bland-Altman plots of agreement in US measurement of the abdominal muscles during the two isometric endurance tests demonstrated that 95% of the observations fall between the limits of agreement for test and retest measurements. Together the results indicate high intra-tester reliability for the US measurement of the thickness of abdominal muscles in all the positions tested. According to the study's findings, US imaging can be used as a reliable method for assessment of abdominal muscles activity in supine lying and the two isometric endurance tests employed, in participants with and without LBP. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Design and Testing of an Educational Water Tunnel

    NASA Astrophysics Data System (ADS)

    Kosaraju, Srinivas

    2017-11-01

    A new water tunnel is designed and tested for educational and research purposes at Northern Arizona University. The university currently owns an educational wind tunnel with a test section of 12in X 12in X 24in. However, due to limited size of test section and range of Reynolds numbers, its application is currently limited to very few experiments. In an effort to expand the educational and research capabilities, a student team is tasked to design, build and test a water tunnel as a Capstone Senior Design project. The water tunnel is designed to have a test section of 8in X 8in X 36in. and be able to test up to Re = 50E3. Multiple numerical models are used to optimize the flow field inside the test section before building the physical apparatus. The water tunnel is designed to accommodate multiple experiments for drag and lift studies. The built-in die system can deliver up to three different colors to study the streamlines and vortex shedding from the surfaces. During the first phase, a low discharge pump is used to achieve Re = 4E3 to test laminar flows. In the second phase, a high discharge pump will be used to achieve targeted Re = 50E3 to study turbulent flows.

  15. Establishing the Brief Assessment of Cognition - Short form.

    PubMed

    Lam, Max; Wang, Mingyuan; Huang, Wanping; Eng, Goi Khia; Rapisarda, Attilio; Kraus, Michael; Kang, Sim; Keefe, R S E; Lee, Jimmy

    2017-10-01

    The study aims to identify and validate a parsimonious subset of tests in the commonly used Brief Assessment of Cognition in Schizophrenia (BACS) that allows the evaluation of global cognitive ability. Several permutations of subtests from the BACS were examined to identify the best subset of tests to compose the short form measure. The Brief Assessment of Cognition-Short Form (BAC-SF) was evaluated for convergent validity in healthy and psychiatric samples (N = 3718). Verbal Memory, Digit Sequencing, and Symbol Coding subtests were found to best summarize the variance of composite scores in both Asian and US Norming samples (r = 0.91) indicating that BAC-SF is an appropriate approximation of cognitive deficits. Test re-test reliability of the BAC-SF was adequate (Intraclass Correlation Coefficient (ICC) = 0.73) and showed sufficient separation between healthy controls and schizophrenia (Average Predictive Accuracy = 79.9%; replication = 76.5%). Findings indicate that the BAC-SF an could be used as a cognitive screener for large-scale clinical and epidemiological studies. The short form does not replace the need for comprehensive neuropsychological batteries purposed for detailed neuropsychological and clinical investigation of cognitive function. Further replication of the construct might be necessary in other clinical populations. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  16. Developing an oropharyngeal cancer (OPC) knowledge and behaviors survey.

    PubMed

    Dodd, Virginia J; Riley Iii, Joseph L; Logan, Henrietta L

    2012-09-01

    To use the community participation research model to (1) develop a survey assessing knowledge about mouth and throat cancer and (2) field test and establish test-retest reliability with newly developed instrument. Cognitive interviews with primarily rural African American adults to assess their perception and interpretation of survey items. Test-retest reliability was established with a racially diverse rural population. Test-retest reliabilities ranged from .79 to .40 for screening awareness and .74 to .19 for knowledge. Coefficients increased for composite scores. Community participation methodology provided a culturally appropriate survey instrument that demonstrated acceptable levels of reliability.

  17. Test-retest reliability of the Progressive Isoinertial Lifting Evaluation (PILE).

    PubMed

    Lygren, Hildegunn; Dragesund, Tove; Joensen, Jón; Ask, Tove; Moe-Nilssen, Rolf

    2005-05-01

    A repeated measures single group design. To investigate test-retest reliability of Progressive Isoinertial Lifting Evaluation on patients with long lasting musculoskeletal problems related to the lumbar spine. Test-retest reliability has been satisfactory in healthy men. Test-retest reliability for clinical populations has not been reported. A total of 31 patients (17 women and 14 men) with long lasting low back pain participated in the study. The patients were tested twice at an interval of 2 days and at the same time of the day. The heaviest load that the patient could lift 4 times was used as outcome measure. The error of measurement indicates that the true result in 95% of cases will be within +/-4.5 kg from the measured value, while the difference between 2 measurements in 95% of cases will be less than 6.4 kg. Intra-class correlation (1,1) was 0.91. Relative test-retest reliability was high assessed by intra-class correlation, but absolute measurement variability reported as the smallest detectable difference has relevance for the interpretation of clinical test results and should also be considered.

  18. Test-retest reliability and practice effects of a rapid screen of mild traumatic brain injury.

    PubMed

    De Monte, Veronica Eileen; Geffen, Gina Malke; Kwapil, Karleigh

    2005-07-01

    Test-retest reliabilities and practice effects of measures from the Rapid Screen of Concussion (RSC), in addition to the Digit Symbol Substitution Test (Digit Symbol), were examined. Twenty five male participants were tested three times; each testing session scheduled a week apart. The test-retest reliability estimates for most measures were reasonably good, ranging from .79 to .97. An exception was the delayed word recall test, which has had a reliability estimate of .66 for the first retest, and .59 for the second retest. Practice effects were evident from Times 1 to 2 on the sentence comprehension and delayed recall subtests of the RSC, Digit Symbol and a composite score. There was also a practice effect of the same magnitude found from Time 2 to Time 3 on Digit Symbol, delayed recall and the composite score. Statistics on measures for both the first and second retest intervals, with associated practice effects, are presented to enable the calculation of reliable change indices (RCI). The RCI may be used to assess any improvement in cognitive functioning after mild Traumatic Brain Injury.

  19. Consortium Requirements Engineering Guidebook

    DTIC Science & Technology

    1993-12-01

    re- quirements among developers or contractors, acquisition managers, and users. A CoRE specification serves as both the test -to and design-to...that are used for the following purposes: (1) the button labeled SELF TEST allows the operator to check the FLMS’s output hardware while the system is...shut down; and (2) the button labeled RESET allows the system to be brought back into normal operation following a shutdown or testing as long as the

  20. Application of identifying transmission spheres for spherical surface testing

    NASA Astrophysics Data System (ADS)

    Han, Christopher B.; Ye, Xin; Li, Xueyuan; Wang, Quanzhao; Tang, Shouhong; Han, Sen

    2017-06-01

    We developed a new application on Microsoft Foundation Classes (MFC) to identify correct transmission spheres (TS) for Spherical Surface Testing (SST). Spherical surfaces are important optical surfaces, and the wide application and high production rate of spherical surfaces necessitates an accurate and highly reliable measuring device. A Fizeau Interferometer is an appropriate tool for SST due to its subnanometer accuracy. It measures the contour of a spherical surface using a common path, which is insensitive to the surrounding circumstances. The Fizeau Interferometer transmits a wide laser beam, creating interference fringes from re-converging light from the transmission sphere and the test surface. To make a successful measurement, the application calculates and determines the appropriate transmission sphere for the test surface. There are 3 main inputs from the test surfaces that are utilized to determine the optimal sizes and F-numbers of the transmission spheres: (1) the curvatures (concave or convex), (2) the Radii of Curvature (ROC), and (3) the aperture sizes. The application will firstly calculate the F-numbers (i.e. ROC divided by aperture) of the test surface, secondly determine the correct aperture size of a convex surface, thirdly verify that the ROC of the test surface must be shorter than the reference surface's ROC of the transmission sphere, and lastly calculate the percentage of area that the test surface will be measured. However, the amount of interferometers and transmission spheres should be optimized when measuring large spherical surfaces to avoid requiring a large amount of interferometers and transmission spheres for each test surface. Current measuring practices involve tedious and potentially inaccurate calculations. This smart application eliminates human calculation errors, optimizes the selection of transmission spheres (including the least number required) and interferometer sizes, and increases efficiency.

  1. When Tests Make You Nervous

    MedlinePlus

    ... you figure out some solutions. For instance, learning study skills can boost your test-day confidence. Be prepared. Pay attention in class. Do your homework. Study for the test. On test day, you're ...

  2. Photovoltaic performance and reliability workshop

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kroposki, B

    1996-10-01

    This proceedings is the compilation of papers presented at the ninth PV Performance and Reliability Workshop held at the Sheraton Denver West Hotel on September 4--6, 1996. This years workshop included presentations from 25 speakers and had over 100 attendees. All of the presentations that were given are included in this proceedings. Topics of the papers included: defining service lifetime and developing models for PV module lifetime; examining and determining failure and degradation mechanisms in PV modules; combining IEEE/IEC/UL testing procedures; AC module performance and reliability testing; inverter reliability/qualification testing; standardization of utility interconnect requirements for PV systems; need activitiesmore » to separate variables by testing individual components of PV systems (e.g. cells, modules, batteries, inverters,charge controllers) for individual reliability and then test them in actual system configurations; more results reported from field experience on modules, inverters, batteries, and charge controllers from field deployed PV systems; and system certification and standardized testing for stand-alone and grid-tied systems.« less

  3. Inventory of Motive of Preference for Conventional Paper-and-Pencil Tests: A Study of Validity and Reliability

    ERIC Educational Resources Information Center

    Eser, Mehmet Taha; Dogan, Nuri

    2017-01-01

    Purpose: The objective of this study is to develop the Inventory of Motive of Preference for Conventional Paper-And-Pencil Tests and to evaluate students' motives for preferring written tests, short-answer tests, true/false tests or multiple-choice tests. This will add a measurement tool to the literature with valid and reliable results to help…

  4. PV Reliability Development Lessons from JPL's Flat Plate Solar Array Project

    NASA Technical Reports Server (NTRS)

    Ross, Ronald G., Jr.

    2013-01-01

    Key reliability and engineering lessons learned from the 20-year history of the Jet Propulsion Laboratory's Flat-Plate Solar Array Project and thin film module reliability research activities are presented and analyzed. Particular emphasis is placed on lessons applicable to evolving new module technologies and the organizations involved with these technologies. The user-specific demand for reliability is a strong function of the application, its location, and its expected duration. Lessons relative to effective means of specifying reliability are described, and commonly used test requirements are assessed from the standpoint of which are the most troublesome to pass, and which correlate best with field experience. Module design lessons are also summarized, including the significance of the most frequently encountered failure mechanisms and the role of encapsulate and cell reliability in determining module reliability. Lessons pertaining to research, design, and test approaches include the historical role and usefulness of qualification tests and field tests.

  5. Overview of RICOR's reliability theoretical analysis, accelerated life demonstration test results and verification by field data

    NASA Astrophysics Data System (ADS)

    Vainshtein, Igor; Baruch, Shlomi; Regev, Itai; Segal, Victor; Filis, Avishai; Riabzev, Sergey

    2018-05-01

    The growing demand for EO applications that work around the clock 24hr/7days a week, such as in border surveillance systems, emphasizes the need for a highly reliable cryocooler having increased operational availability and optimized system's Integrated Logistic Support (ILS). In order to meet this need, RICOR developed linear and rotary cryocoolers which achieved successfully this goal. Cryocoolers MTTF was analyzed by theoretical reliability evaluation methods, demonstrated by normal and accelerated life tests at Cryocooler level and finally verified by field data analysis derived from Cryocoolers operating at system level. The following paper reviews theoretical reliability analysis methods together with analyzing reliability test results derived from standard and accelerated life demonstration tests performed at Ricor's advanced reliability laboratory. As a summary for the work process, reliability verification data will be presented as a feedback from fielded systems.

  6. The Examination of Reliability According to Classical Test and Generalizability on a Job Performance Scale

    ERIC Educational Resources Information Center

    Yelboga, Atilla; Tavsancil, Ezel

    2010-01-01

    In this research, the classical test theory and generalizability theory analyses were carried out with the data obtained by a job performance scale for the years 2005 and 2006. The reliability coefficients obtained (estimated) from the classical test theory and generalizability theory analyses were compared. In classical test theory, test retest…

  7. System reliability analysis through corona testing

    NASA Technical Reports Server (NTRS)

    Lalli, V. R.; Mueller, L. A.; Koutnik, E. A.

    1975-01-01

    A corona vacuum test facility for nondestructive testing of power system components was built in the Reliability and Quality Engineering Test Laboratories at the NASA Lewis Research Center. The facility was developed to simulate operating temperature and vacuum while monitoring corona discharges with residual gases. The facility is being used to test various high-voltage power system components.

  8. An Evaluation of Test Speededness in an Assessment for Third-Grade Gifted Students

    ERIC Educational Resources Information Center

    Hailey, Emily; Callahan, Carolyn M.; Azano, Amy; Moon, Tonya R.

    2012-01-01

    Reliability and validity are integral concepts in assessment design. Test speededness, the influence of time constraints on test taker performance, is often an overlooked threat to reliability and validity, especially in classroom-based testing. The purpose of this study is to evaluate the degree of test speededness of classroom-based assessments…

  9. Auditory threshold shifts after glycerol administration to patients with suspected Menière's disease: a retrospective analysis.

    PubMed

    Basel, Türker; Lütkenhöner, Bernd

    2013-01-01

    Nearly half a century ago, administration of glycerol was shown to temporarily improve the threshold of hearing in patients with suspected Menière's disease (glycerol test). Although a positive test result provides strong evidence of Menière's disease, the test has not gained widespread acceptance. A probable reason is that there is no consensus as to the definition of positive. Moreover, a negative test result is of little diagnostic value because Menière's disease cannot be excluded. By reanalyzing archived data, the authors sought to understand the test in light of signal detection theory. Moreover, they explored the possibility of estimating the probability of a positive test result from the pretest audiogram. The study is based on audiograms from 347 patients (356 ears) who underwent a glycerol test to corroborate a suspected diagnosis of Menière's disease. Subsequent to an initial pure-tone audiogram, glycerol (1.2 mL/kg body weight) was orally administered; follow-up audiograms were obtained after 1, 2, 3, and 4 hr. Transcription of the audiograms into a computer-readable form made them available for automated reanalysis. Averaged difference audiograms provided detailed insight into the frequency dependence and the temporal dynamics of the glycerol-induced threshold reduction. The strongest threshold reduction was observed 4 hr after glycerol intake, although nearly the same effect was already found after 3 hr. Strong overall threshold reductions were associated with a pronounced maximum at approximately 1000 Hz; weaker effects were associated with a plateau between 125 and 1000 Hz and a rapid decrease toward higher frequencies. To date, criteria suggested for a positive test result vastly differ in both sensitivity (with regard to the detection of a threshold reduction) and specificity (1 minus false-positive rate). Here, a criterion based on the aggregate threshold reduction in adjacent audiometric frequencies is suggested. This approach does not only seem to be more robust but also permits to freely adjust the false-positive rate. A positive test result is particularly likely when the mean low-frequency hearing loss is approximately 60 dB and the mean high-frequency hearing loss does not exceed 50 dB. If the pretest audiogram does not render a positive test result unlikely, a state-of-the-art implementation of the glycerol test is a competitive method for corroborating a suspected diagnosis of Menière's disease.

  10. Vertical-axis wind turbine experiments at full dynamic similarity

    NASA Astrophysics Data System (ADS)

    Duvvuri, Subrahmanyam; Miller, Mark; Brownstein, Ian; Dabiri, John; Hultmark, Marcus

    2017-11-01

    This study presents results from pressurized (upto 200 atm) wind tunnel tests of a self-spinning 5-blade model Vertical-Axis Wind Turbine (VAWT). The model is geometrically similar (scale ratio 1:22) to a commercially available VAWT, which has a rotor diameter of 2.17 meters and blade span of 3.66 meters, and is used at the Stanford university field lab. The use of pressurized air as working fluid allows for the unique ability to obtain full dynamic similarity with field conditions in terms of matched Reynolds numbers (Re), tip-speed ratios (λ), and Mach number (M). Tests were performed across a wide range of Re and λ, with the highest Re exceeding the maximum operational field Reynolds number (Remax) by a factor of 3. With an extended range of accessible Re conditions, the peak turbine power efficiency was seen to occur roughly at Re = 2 Remax and λ = 1 . Beyond Re > 2 Remax the turbine performance is invariant in Re for all λ. A clear demonstration of Reynolds number invariance for an actual full-scale wind turbine lends novelty to this study, and overall the results show the viability of the present experimental technique in testing turbines at field conditions.

  11. MRI-Guided Regional Personalized Electrical Stimulation in Multisession and Home Treatments

    PubMed Central

    Cancelli, Andrea; Cottone, Carlo; Giordani, Alessandro; Asta, Giampiero; Lupoi, Domenico; Pizzella, Vittorio; Tecchio, Franca

    2018-01-01

    The shape and position of the electrodes is a key factor for the efficacy of transcranial electrical stimulations (tES). We have recently introduced the Regional Personalized Electrode (RePE), a tES electrode fitting the personal cortical folding, that has been able to differentiate the stimulation of close by regions, in particular the primary sensory (S1) and motor (M1) cortices, and to personalize tES onto such an extended cortical district. However, neuronavigation on individual brain was compulsory for the correct montage. Here, we aimed at developing and testing a neuronavigation-free procedure for easy and quick positioning RePE, enabling multisession RePE-tES at home. We used off-line individual MRI to shape RePE via an ad-hoc computerized procedure, while an ad-hoc developed Adjustable Helmet Frame (AHF) was used to properly position it in multisession treatments, even at home. We used neuronavigation to test the RePE shape and position obtained by the new computerized procedure and the re-positioning obtained via the AHF. Using Finite Element Method (FEM) model, we also estimated the intra-cerebral current distribution induced by transcranial direct current stimulation (tDCS) comparing RePE vs. non-RePE with fixed reference. Additionally, we tested, using FEM, various shapes, and positions of the reference electrode taking into account possible small displacements of RePE, to test feasibility of RePE-tES sessions at home. The new RePE neuronavigation-free positioning relies on brain MRI space distances, and produced a mean displacement of 3.5 ± 0.8 mm, and the re-positioning of 4.8 ± 1.1 mm. Higher electric field in S1 than in M1 was best obtained with the occipital reference electrode, a montage that proved to feature low sensitivity to typical RePE millimetric displacements. Additionally, a new tES accessory was developed to enable repositioning the electrodes over the scalp also at home, with a precision which is acceptable according to the modeling-estimated intracerebral currents. Altogether, we provide here a procedure to simplify and make easily applicable RePE-tDCS, which enables efficacious personalized treatments. PMID:29867308

  12. Reliability Generalization of the Alcohol Use Disorder Identification Test.

    ERIC Educational Resources Information Center

    Shields, Alan L.; Caruso, John C.

    2002-01-01

    Evaluated the reliability of scores from the Alcohol Use Disorders Identification Test (AUDIT; J. Sounders and others, 1993) in a reliability generalization study based on 17 empirical journal articles. Results show AUDIT scores to be generally reliable for basic assessment. (SLD)

  13. Statistical Considerations in Choosing a Test Reliability Coefficient. ACT Research Report Series, 2012 (10)

    ERIC Educational Resources Information Center

    Woodruff, David; Wu, Yi-Fang

    2012-01-01

    The purpose of this paper is to illustrate alpha's robustness and usefulness, using actual and simulated educational test data. The sampling properties of alpha are compared with the sampling properties of several other reliability coefficients: Guttman's lambda[subscript 2], lambda[subscript 4], and lambda[subscript 6]; test-retest reliability;…

  14. Validity and Reliability of a Medicine Ball Explosive Power Test.

    ERIC Educational Resources Information Center

    Stockbrugger, Barry A.; Haennel, Robert G.

    2001-01-01

    Evaluated the validity and reliability of a medicine ball throw test to evaluate explosive power. Data on competitive sand volleyball players who performed a medicine ball throw and a standard countermovement jump indicated that the medicine ball throw test was a valid and reliable way to assess explosive power for an analogous total-body movement…

  15. Reliability of laboratory measurement of human food intake.

    PubMed

    Laessle, R; Geiermann, L

    2012-02-01

    The universal eating monitor (UEM) of Kissileff for laboratory measurement of food intake was modified and used with a newly developed special software to compute cumulative intake data. To explore the measurement precision of the UEM an investigation of test-retest-reliability of food intake parameters was conducted. The intake characteristics of 125 males and females were measured repeatedly in the laboratory with a measurement interval of 1 week. Pudding of preferred flavour served as test meal. Test-retest-reliability of intake characteristics ranged from .49 (change of eating rate) to .89 (initial eating rate). All test-retest correlations were highly significant. Sex, BMI and eating habits according to TFEQ-factors had no significant effects on reliability of intake characteristics. The test-retest-reliability of the laboratory intake measures is as good as those of personality questionnaires, where it should be better than .80. Reliability coefficients are valid independent of sex, BMI or trait characteristics of eating behaviour. Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. Reliability and Construct Validity of Limits of Stability Test in Adolescents Using a Portable Forceplate System.

    PubMed

    Alsalaheen, Bara; Haines, Jamie; Yorke, Amy; Broglio, Steven P

    2015-12-01

    To examine the reliability, convergent, and discriminant validity of the limits of stability (LOS) test to assess dynamic postural stability in adolescents using a portable forceplate system. Cross-sectional reliability observational study. School setting. Adolescents (N=36) completed all measures during the first session. To examine the reliability of the LOS test, a subset of 15 participants repeated the LOS test after 1 week. Not applicable. Outcome measurements included the LOS test, Balance Error Scoring System, Instrumented Balance Error Scoring System, and Modified Clinical Test for Sensory Interaction on Balance. A significant relation was observed among LOS composite scores (r=.36-.87, P<.05). However, no relation was observed between LOS and static balance outcome measurements. The reliability of the LOS composite scores ranged from moderate to good (intraclass correlation coefficient model 2,1=.73-.96). The results suggest that the LOS composite scores provide unique information about dynamic postural stability, and the LOS test completed at 100% of the theoretical limit appeared to be a reliable test of dynamic postural stability in adolescents. Clinicians should use dynamic balance measurement as part of their balance assessment and should not use static balance testing (eg, Balance Error Scoring System) to make inferences about dynamic balance, especially when balance assessment is used to determine rehabilitation outcomes, or when making return to play decisions after injury. Copyright © 2015 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  17. The Reliability of Pharyngeal High Resolution Manometry with Impedance for Derivation of Measures of Swallowing Function in Healthy Volunteers

    PubMed Central

    Omari, Taher I.; Savilampi, Johanna; Kokkinn, Karmen; Schar, Mistyka; Lamvik, Kristin; Doeltgen, Sebastian; Cock, Charles

    2016-01-01

    Purpose. We evaluated the intra- and interrater agreement and test-retest reliability of analyst derivation of swallow function variables based on repeated high resolution manometry with impedance measurements. Methods. Five subjects swallowed 10 × 10 mL saline on two occasions one week apart producing a database of 100 swallows. Swallows were repeat-analysed by six observers using software. Swallow variables were indicative of contractility, intrabolus pressure, and flow timing. Results. The average intraclass correlation coefficients (ICC) for intra- and interrater comparisons of all variable means showed substantial to excellent agreement (intrarater ICC 0.85–1.00; mean interrater ICC 0.77–1.00). Test-retest results were less reliable. ICC for test-retest comparisons ranged from slight to excellent depending on the class of variable. Contractility variables differed most in terms of test-retest reliability. Amongst contractility variables, UES basal pressure showed excellent test-retest agreement (mean ICC 0.94), measures of UES postrelaxation contractile pressure showed moderate to substantial test-retest agreement (mean Interrater ICC 0.47–0.67), and test-retest agreement of pharyngeal contractile pressure ranged from slight to substantial (mean Interrater ICC 0.15–0.61). Conclusions. Test-retest reliability of HRIM measures depends on the class of variable. Measures of bolus distension pressure and flow timing appear to be more test-retest reliable than measures of contractility. PMID:27190520

  18. Validity and Reliability of Baseline Testing in a Standardized Environment.

    PubMed

    Higgins, Kathryn L; Caze, Todd; Maerlender, Arthur

    2017-08-11

    The Immediate Postconcussion Assessment and Cognitive Testing (ImPACT) is a computerized neuropsychological test battery commonly used to determine cognitive recovery from concussion based on comparing post-injury scores to baseline scores. This model is based on the premise that ImPACT baseline test scores are a valid and reliable measure of optimal cognitive function at baseline. Growing evidence suggests that this premise may not be accurate and a large contributor to invalid and unreliable baseline test scores may be the protocol and environment in which baseline tests are administered. This study examined the effects of a standardized environment and administration protocol on the reliability and performance validity of athletes' baseline test scores on ImPACT by comparing scores obtained in two different group-testing settings. Three hundred-sixty one Division 1 cohort-matched collegiate athletes' baseline data were assessed using a variety of indicators of potential performance invalidity; internal reliability was also examined. Thirty-one to thirty-nine percent of the baseline cases had at least one indicator of low performance validity, but there were no significant differences in validity indicators based on environment in which the testing was conducted. Internal consistency reliability scores were in the acceptable to good range, with no significant differences between administration conditions. These results suggest that athletes may be reliably performing at levels lower than their best effort would produce. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  19. Unanticipated Effects of Epoxy Impregnating Transformers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    SANCHEZ,ROBERT O.; ARCHER,WENDEL E.

    2000-08-23

    Many Sandia components for military applications are designed for a 20-year life. In order to determine if magnetic components meet that requirement, the parts are subjected to selected destructive tests. This paper reviews the re-design of a power transformer and the tests required to prove-in the re-design. The re-design included replacing the Epon 828/Mica/methylenedianiline (curing agent Z) epoxy encapsulant with a recent Sandia National Laboratory (SNL) developed epoxy encapsulant. The new encapsulant reduces the Environmental Safety and Health (ES and H) hazards. Life testing of this re-designed transformer generated failures; an open secondary winding. An experimental program to determine themore » cause of the broken wires and an improved design to eliminate the problem was executed. This design weakness was corrected by reverting to the hazardous epoxy system.« less

  20. On-clip high frequency reliability and failure test structures

    DOEpatents

    Snyder, Eric S.; Campbell, David V.

    1997-01-01

    Self-stressing test structures for realistic high frequency reliability characterizations. An on-chip high frequency oscillator, controlled by DC signals from off-chip, provides a range of high frequency pulses to test structures. The test structures provide information with regard to a variety of reliability failure mechanisms, including hot-carriers, electromigration, and oxide breakdown. The system is normally integrated at the wafer level to predict the failure mechanisms of the production integrated circuits on the same wafer.

  1. Reliability of specific physical examination tests for the diagnosis of shoulder pathologies: a systematic review and meta-analysis.

    PubMed

    Lange, Toni; Matthijs, Omer; Jain, Nitin B; Schmitt, Jochen; Lützner, Jörg; Kopkow, Christian

    2017-03-01

    Shoulder pain in the general population is common and to identify the aetiology of shoulder pain, history, motion and muscle testing, and physical examination tests are usually performed. The aim of this systematic review was to summarise and evaluate intrarater and inter-rater reliability of physical examination tests in the diagnosis of shoulder pathologies. A comprehensive systematic literature search was conducted using MEDLINE, EMBASE, Allied and Complementary Medicine Database (AMED) and Physiotherapy Evidence Database (PEDro) through 20 March 2015. Methodological quality was assessed using the Quality Appraisal of Reliability Studies (QAREL) tool by 2 independent reviewers. The search strategy revealed 3259 articles, of which 18 finally met the inclusion criteria. These studies evaluated the reliability of 62 test and test variations used for the specific physical examination tests for the diagnosis of shoulder pathologies. Methodological quality ranged from 2 to 7 positive criteria of the 11 items of the QAREL tool. This review identified a lack of high-quality studies evaluating inter-rater as well as intrarater reliability of specific physical examination tests for the diagnosis of shoulder pathologies. In addition, reliability measures differed between included studies hindering proper cross-study comparisons. PROSPERO CRD42014009018. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  2. Reliability and validity of a talent identification test battery for seated and standing Paralympic throws.

    PubMed

    Spathis, Jemima Grace; Connick, Mark James; Beckman, Emma Maree; Newcombe, Peter Anthony; Tweedy, Sean Michael

    2015-01-01

    Paralympic throwing events for athletes with physical impairments comprise seated and standing javelin, shot put, discus and seated club throwing. Identification of talented throwers would enable prediction of future success and promote participation; however, a valid and reliable talent identification battery for Paralympic throwing has not been reported. This study evaluates the reliability and validity of a talent identification battery for Paralympic throws. Participants were non-disabled so that impairment would not confound analyses, and results would provide an indication of normative performance. Twenty-eight non-disabled participants (13 M; 15 F) aged 23.6 years (±5.44) performed five kinematically distinct criterion throws (three seated, two standing) and nine talent identification tests (three anthropometric, six motor); 23 were tested a second time to evaluate test-retest reliability. Talent identification test-retest reliability was evaluated using Intra-class Correlation Coefficient (ICC) and Bland-Altman plots (Limits of Agreement). Spearman's correlation assessed strength of association between criterion throws and talent identification tests. Reliability was generally acceptable (mean ICC = 0.89), but two seated talent identification tests require more extensive familiarisation. Correlation strength (mean rs = 0.76) indicated that the talent identification tests can be used to validly identify individuals with competitively advantageous attributes for each of the five kinematically distinct throwing activities. Results facilitate further research in this understudied area.

  3. Test-Retest Reliability of Measures Commonly Used to Measure Striatal Dysfunction across Multiple Testing Sessions: A Longitudinal Study.

    PubMed

    Palmer, Clare E; Langbehn, Douglas; Tabrizi, Sarah J; Papoutsi, Marina

    2017-01-01

    Cognitive impairment is common amongst many neurodegenerative movement disorders such as Huntington's disease (HD) and Parkinson's disease (PD) across multiple domains. There are many tasks available to assess different aspects of this dysfunction, however, it is imperative that these show high test-retest reliability if they are to be used to track disease progression or response to treatment in patient populations. Moreover, in order to ensure effects of practice across testing sessions are not misconstrued as clinical improvement in clinical trials, tasks which are particularly vulnerable to practice effects need to be highlighted. In this study we evaluated test-retest reliability in mean performance across three testing sessions of four tasks that are commonly used to measure cognitive dysfunction associated with striatal impairment: a combined Simon Stop-Signal Task; a modified emotion recognition task; a circle tracing task; and the trail making task. Practice effects were seen between sessions 1 and 2 across all tasks for the majority of dependent variables, particularly reaction time variables; some, but not all, diminished in the third session. Good test-retest reliability across all sessions was seen for the emotion recognition, circle tracing, and trail making test. The Simon interference effect and stop-signal reaction time (SSRT) from the combined-Simon-Stop-Signal task showed moderate test-retest reliability, however, the combined SSRT interference effect showed poor test-retest reliability. Our results emphasize the need to use control groups when tracking clinical progression or use pre-baseline training on tasks susceptible to practice effects.

  4. Computational prediction of over-annotated protein-coding genes in the genome of Agrobacterium tumefaciens strain C58

    NASA Astrophysics Data System (ADS)

    Yu, Jia-Feng; Sui, Tian-Xiang; Wang, Hong-Mei; Wang, Chun-Ling; Jing, Li; Wang, Ji-Hua

    2015-12-01

    Agrobacterium tumefaciens strain C58 is a type of pathogen that can cause tumors in some dicotyledonous plants. Ever since the genome of A. tumefaciens strain C58 was sequenced, the quality of annotation of its protein-coding genes has been queried continually, because the annotation varies greatly among different databases. In this paper, the questionable hypothetical genes were re-predicted by integrating the TN curve and Z curve methods. As a result, 30 genes originally annotated as “hypothetical” were discriminated as being non-coding sequences. By testing the re-prediction program 10 times on data sets composed of the function-known genes, the mean accuracy of 99.99% and mean Matthews correlation coefficient value of 0.9999 were obtained. Further sequence analysis and COG analysis showed that the re-annotation results were very reliable. This work can provide an efficient tool and data resources for future studies of A. tumefaciens strain C58. Project supported by the National Natural Science Foundation of China (Grant Nos. 61302186 and 61271378) and the Funding from the State Key Laboratory of Bioelectronics of Southeast University.

  5. Is there a risk of active sensitization to PPD by patch testing the general population?

    PubMed

    Thyssen, Jacob Pontoppidan; Menné, Torkil; Nielsen, Niels Henrik; Linneberg, Allan

    2007-08-01

    Para-phenylenediamine (PPD), a constituent of permanent hair dyes, may cause contact allergy in exposed individuals. It has previously been questioned whether a patch testing with PPD in population-based epidemiological studies is entirely safe. The Glostrup allergy studies patch tested the same cohort twice. In 1990, 567 persons were patch-tested and only one person had a (+) positive reaction to PPD. In 1998, 540 persons were re-invited to a new patch test and 365 (participation rate 68%) were re-tested. There were no positive reactions to PPD. These studies indicate that patch testing with PPD in individuals with no previous positive reactions to PPD or with only one previous positive reaction does not cause active sensitization and can be performed with minimal risk.

  6. A pilot study examining density of suppression measurement in strabismus.

    PubMed

    Piano, Marianne; Newsham, David

    2015-01-01

    Establish whether the Sbisa bar, Bagolini filter (BF) bar, and neutral density filter (NDF) bar, used to measure density of suppression, are equivalent and possess test-retest reliability. Determine whether density of suppression is altered when measurement equipment/testing conditions are changed. Our pilot study had 10 subjects aged ≥18 years with childhood-onset strabismus, no ocular pathologies, and no binocular vision when manifest. Density of suppression upon repeated testing, with clinic lights on/off, and using a full/reduced intensity light source, was investigated. Results were analysed for test-retest reliability, equivalence, and changes with alteration of testing conditions. Test-retest reliability issues were present for the BF bar (median 6 filter change from first to final test, p = 0.021) and NDF bar (median 5 filter change from first to final test, p = 0.002). Density of suppression was unaffected by environmental illumination or fixation light intensity variations. Density of suppression measurements were higher when measured with the NDF bar (e.g. NDF bar = 1.5, medium suppression, vs BF bar = 6.5, light suppression). Test-retest reliability issues may be present for the two filter bars currently still under manufacture. Changes in testing conditions do not significantly affect test results, provided the same filter bar is used consistently for testing. Further studies in children with strabismus having active amblyopia treatment would be of benefit. Despite extensive use of these tests in the UK, this is to our knowledge the first study evaluating filter bar equivalence/reliability.

  7. Identifying disease polymorphisms from case-control genetic association data.

    PubMed

    Park, L

    2010-12-01

    In case-control association studies, it is typical to observe several associated polymorphisms in a gene region. Often the most significantly associated polymorphism is considered to be the disease polymorphism; however, it is not clear whether it is the disease polymorphism or there is more than one disease polymorphism in the gene region. Currently, there is no method that can handle these problems based on the linkage disequilibrium (LD) relationship between polymorphisms. To distinguish real disease polymorphisms from markers in LD, a method that can detect disease polymorphisms in a gene region has been developed. Relying on the LD between polymorphisms in controls, the proposed method utilizes model-based likelihood ratio tests to find disease polymorphisms. This method shows reliable Type I and Type II error rates when sample sizes are large enough, and works better with re-sequenced data. Applying this method to fine mapping using re-sequencing or dense genotyping data would provide important information regarding the genetic architecture of complex traits.

  8. Reliability and main findings of the FEES-Tensilon Test in patients with myasthenia gravis and dysphagia.

    PubMed

    Im, Sun; Suntrup-Krueger, Sonja; Colbow, Sigrid; Sauer, Sonja; Claus, Inga; Meuth, Sven G; Dziewas, Rainer; Warnecke, Tobias

    2018-05-26

    Diagnosis of pharyngeal dysphagia caused by myasthenia gravis (MG) based on clinical examination alone is often challenging. Flexible endoscopic evaluation of swallowing (FEES) combined with Tensilon (edrophonium) application, referred to as the FEES-Tensilon Test, was developed to improve diagnostic accuracy and to detect the main symptoms of pharyngeal dysphagia in MG. Here we investigated inter- and intra-rater reliability of the FEES-Tensilon Test and analyzed the main endoscopic findings. Four experienced raters reviewed a total of 20 FEES-Tensilon-Test videos in randomized order. Residue severity was graded at 4 different pharyngeal spaces before and after Tensilon administration. All interpretations were performed twice per rater, 4 weeks apart (a total of 160 scorings). Intra-rater test-retest reliability and inter-rater reliability levels were calculated. The most frequent FEES findings in MG patients before Tensilon application were prominent residues of semi solids spread all over the hypopharynx in varying locations. The reliability level in the interpretation of the FEES-Tensilon test was excellent regardless of the raters' profession or years of experience with FEES. All 4 raters showed high inter- and intra- reliability levels in interpreting the FEES-Tensilon Test based on residue clearance (kappa=0.922, 0.981). Degree of residue normalization in the vallecular space after Tensilon application showed the highest inter- and intra-rater reliability level (kappa=0.863, 0.957) followed by the epiglottis (kappa=0.813, 0.946) and pyriform sinuses (kappa=0.836, 0.929). Interpretation of the FEES-Tensilon Test based on residue severity and degree of Tensilon clearance, especially in the vallecular space, is consistent and reliable. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  9. Exercise-Induced Hypoalgesia After Isometric Wall Squat Exercise: A Test-Retest Reliabilty Study.

    PubMed

    Vaegter, Henrik Bjarke; Lyng, Kristian Damgaard; Yttereng, Fredrik Wannebo; Christensen, Mads Holst; Sørensen, Mathias Brandhøj; Graven-Nielsen, Thomas

    2018-05-19

    Isometric exercises decrease pressure pain sensitivity in exercising and nonexercising muscles known as exercise-induced hypoalgesia (EIH). No studies have assessed the test-retest reliability of EIH after isometric exercise. This study investigated the EIH on pressure pain thresholds (PPTs) after an isometric wall squat exercise. The relative and absolute test-retest reliability of the PPT as a test stimulus and the EIH response in exercising and nonexercising muscles were calculated. In two identical sessions, PPTs of the thigh and shoulder were assessed before and after three minutes of quiet rest and three minutes of wall squat exercise, respectively, in 35 healthy subjects. The relative test-retest reliability of PPT and EIH was determined using analysis of variance models, Person's r, and intraclass correlations (ICCs). The absolute test-retest reliability of EIH was determined based on PPT standard error of measurements and Cohen's kappa for agreement between sessions. Squat increased PPTs of exercising and nonexercising muscles by 16.8% ± 16.9% and 6.7% ± 12.9%, respectively (P < 0.001), with no significant differences between sessions. PPTs within and between sessions showed moderately strong correlations (r ≥ 0.74) and excellent (ICC ≥ 0.84) within-session (rest) and between-session test-retest reliability. EIH responses of exercising and nonexercising muscles showed no systematic errors between sessions; however, the relative test-retest reliability was low (ICCs = 0.03-0.43), and agreement in EIH responders and nonresponders between sessions was not significant (κ < 0.13, P > 0.43). A wall squat exercise increased PPTs compared with quiet rest; however, the relative and absolute reliability of the EIH response was poor. Future research is warranted to investigate the reliability of EIH in clinical pain populations.

  10. Development of an in vitro test battery for assessing chemical effects on bovine germ cells under the ReProTect umbrella

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lazzari, Giovanna; Tessaro, Irene; Crotti, Gabriella

    2008-12-15

    Current European legislation for the registration and authorisation of chemicals (REACH) will require a dramatic increase in the use of animals for reproductive toxicity testing. Since one objective of REACH is to use vertebrates only as last resort, the development and validation of alternative methods is urgently needed. For this purpose ReProTect, an integrated research project funded by the European Union, joining together 33 partners with complementary expertise in reproductive toxicology, was designed. The study presented here describes a battery of two tests developed within ReProTect. The objective of these tests is the detection of chemical effects during the processesmore » of oocyte maturation and fertilisation in a bovine model. The corresponding toxicological endpoints are the reaching of metaphase II and the formation of the pronuclei respectively. Fifteen chemicals have been tested (Benzo[a]pyrene, Busulfan, Butylparaben, Cadmium Chloride, Carbendazim, Cycloheximide, Diethylstilbestrol, Genistein, Ionomycin, Ketoconazole, Lindane, Methylacetoacetate, Mifepristone, Nocodazole and DMSO as solvent) demonstrating high intra-laboratory reproducibility of the tests. Furthermore, the responses obtained in both tests, for several substances, had a good correlation with the available in vivo and in vitro data. These tests therefore, could predictably become part of an integrated testing strategy that combines the bovine models with additional in vitro tests, in order to predict chemical hazards on mammalian fertility.« less

  11. Investing American Recovery and Reinvestment Act Funds to Advance Capability, Reliability, and Performance in NASA Wind Tunnels

    NASA Technical Reports Server (NTRS)

    Sydnor, Goerge H.

    2010-01-01

    The National Aeronautics and Space Administration's (NASA) Aeronautics Test Program (ATP) is implementing five significant ground-based test facility projects across the nation with funding provided by the American Recovery and Reinvestment Act (ARRA). The projects were selected as the best candidates within the constraints of the ARRA and the strategic plan of ATP. They are a combination of much-needed large scale maintenance, reliability, and system upgrades plus creating new test beds for upcoming research programs. The projects are: 1.) Re-activation of a large compressor to provide a second source for compressed air and vacuum to the Unitary Plan Wind Tunnel at the Ames Research Center (ARC) 2.) Addition of high-altitude ice crystal generation at the Glenn Research Center Propulsion Systems Laboratory Test Cell 3, 3.) New refrigeration system and tunnel heat exchanger for the Icing Research Tunnel at the Glenn Research Center, 4.) Technical viability improvements for the National Transonic Facility at the Langley Research Center, and 5.) Modifications to conduct Environmentally Responsible Aviation and Rotorcraft research at the 14 x 22 Subsonic Tunnel at Langley Research Center. The selection rationale, problem statement, and technical solution summary for each project is given here. The benefits and challenges of the ARRA funded projects are discussed. Indirectly, this opportunity provides the advantages of developing experience in NASA's workforce in large projects and maintaining corporate knowledge in that very unique capability. It is envisioned that improved facilities will attract a larger user base and capabilities that are needed for current and future research efforts will offer revenue growth and future operations stability. Several of the chosen projects will maximize wind tunnel reliability and maintainability by using newer, proven technologies in place of older and obsolete equipment and processes. The projects will meet NASA's goal of integrating more efficient, environmentally safer, and less energy consuming hardware and processes into existing tunnel systems. These include Environmental Protection Agency-approved refrigerants, energy efficient motors, and faster, flexible tunnel data systems.

  12. Development and pilot testing of an online module for ethics education based on the Nigerian National Code for Health Research Ethics

    PubMed Central

    2013-01-01

    Background The formulation and implementation of national ethical regulations to protect research participants is fundamental to ethical conduct of research. Ethics education and capacity are inadequate in developing African countries. This study was designed to develop a module for online training in research ethics based on the Nigerian National Code of Health Research Ethics and assess its ease of use and reliability among biomedical researchers in Nigeria. Methodology This was a three-phased evaluation study. Phase one involved development of an online training module based on the Nigerian Code of Health Research Ethics (NCHRE) and uploading it to the Collaborative Institutional Training Initiative (CITI) website while the second phase entailed the evaluation of the module for comprehensibility, readability and ease of use by 45 Nigerian biomedical researchers. The third phase involved modification and re-evaluation of the module by 30 Nigerian biomedical researchers and determination of test-retest reliability of the module using Cronbach’s alpha. Results The online module was easily accessible and comprehensible to 95% of study participants. There were significant differences in the pretest and posttest scores of study participants during the evaluation of the online module (p = 0.001) with correlation coefficients of 0.9 and 0.8 for the pretest and posttest scores respectively. The module also demonstrated excellent test-retest reliability and internal consistency as shown by Cronbach’s alpha coefficients of 0.92 and 0.84 for the pretest and posttest respectively. Conclusion The module based on the Nigerian Code was developed, tested and made available online as a valuable tool for training in cultural and societal relevant ethical principles to orient national and international biomedical researchers working in Nigeria. It would complement other general research ethics and Good Clinical Practice modules. Participants suggested that awareness of the online module should be increased through seminars, advertisement on government websites and portals used by Nigerian biomedical researchers, and incorporation of the Code into the undergraduate medical training curriculum. PMID:23281968

  13. Educational testing validity and reliability in pharmacy and medical education literature.

    PubMed

    Hoover, Matthew J; Jung, Rose; Jacobs, David M; Peeters, Michael J

    2013-12-16

    To evaluate and compare the reliability and validity of educational testing reported in pharmacy education journals to medical education literature. Descriptions of validity evidence sources (content, construct, criterion, and reliability) were extracted from articles that reported educational testing of learners' knowledge, skills, and/or abilities. Using educational testing, the findings of 108 pharmacy education articles were compared to the findings of 198 medical education articles. For pharmacy educational testing, 14 articles (13%) reported more than 1 validity evidence source while 83 articles (77%) reported 1 validity evidence source and 11 articles (10%) did not have evidence. Among validity evidence sources, content validity was reported most frequently. Compared with pharmacy education literature, more medical education articles reported both validity and reliability (59%; p<0.001). While there were more scholarship of teaching and learning (SoTL) articles in pharmacy education compared to medical education, validity, and reliability reporting were limited in the pharmacy education literature.

  14. Accounting for Proof Test Data in a Reliability Based Design Optimization Framework

    NASA Technical Reports Server (NTRS)

    Ventor, Gerharad; Scotti, Stephen J.

    2012-01-01

    This paper investigates the use of proof (or acceptance) test data during the reliability based design optimization of structural components. It is assumed that every component will be proof tested and that the component will only enter into service if it passes the proof test. The goal is to reduce the component weight, while maintaining high reliability, by exploiting the proof test results during the design process. The proposed procedure results in the simultaneous design of the structural component and the proof test itself and provides the designer with direct control over the probability of failing the proof test. The procedure is illustrated using two analytical example problems and the results indicate that significant weight savings are possible when exploiting the proof test results during the design process.

  15. Interpreting studies of cognitive function following cardiac surgery: a guide for surgical teams.

    PubMed

    Rubens, Fraser D; Boodhwani, Munir; Nathan, Howard

    2007-05-01

    Patients with coronary disease and related health care providers are faced with confusing and often conflicting information with regards to the neurocognitive impact of different strategies for coronary revascularization. Studies involving the measurement of postoperative cognitive deficit (POCD) have significant limitations that may ultimately impact on their interpretation and clinical relevance. In this review, we have described the origin of these tests and delineated the rationale for the design of testing that is commonly used in cardiac surgery patients. In general, neurocognitive tests assess domains of memory/new learning, psychomotor speed/dexterity and attentional capacity/mental control. Pre- and post-intervention tests in each domain can be evaluated either by the measurement of mean change scores (Group Comparison Model) for the entire group as continuous data, or by using categorical or continuous data to examine patterns of individual decline (Individual Comparison Model). This latter approach requires a specific definition of what constitutes a decline, which can be criticized as being arbitrary. There are limitations to each of these approaches that necessitate that critical information in trial design is available to the reviewer to facilitate interpretation. For example, the impact of factors such as test/re-test reliability and practice effect can be mitigated by the use of an appropriately chosen control population. Liberal parlance of neurocognitive outcome as a rationale for therapeutic choice must be tempered by wise interpretation of these tests. It is only through the understanding of their limitations and the implications of trial design that we can translate these results to provide the best therapeutic options for our patients in unbiased manner.

  16. Software Reliability, Measurement, and Testing. Volume 2. Guidebook for Software Reliability Measurement and Testing

    DTIC Science & Technology

    1992-04-01

    contractor’s existing data collection, analysis and corrective action system shall be utilized, with modification only as necessary to meet the...either from test or from analysis of field data . The procedures of MIL-STD-756B assume that the reliability of a 18 DEFINE IDENTIFY SOFTWARE LIFE CYCLE...to generate sufficient data to report a statistically valid reliability figure for a class of software. Casual data gathering accumulates data more

  17. Quantitative metal magnetic memory reliability modeling for welded joints

    NASA Astrophysics Data System (ADS)

    Xing, Haiyan; Dang, Yongbin; Wang, Ben; Leng, Jiancheng

    2016-03-01

    Metal magnetic memory(MMM) testing has been widely used to detect welded joints. However, load levels, environmental magnetic field, and measurement noises make the MMM data dispersive and bring difficulty to quantitative evaluation. In order to promote the development of quantitative MMM reliability assessment, a new MMM model is presented for welded joints. Steel Q235 welded specimens are tested along the longitudinal and horizontal lines by TSC-2M-8 instrument in the tensile fatigue experiments. The X-ray testing is carried out synchronously to verify the MMM results. It is found that MMM testing can detect the hidden crack earlier than X-ray testing. Moreover, the MMM gradient vector sum K vs is sensitive to the damage degree, especially at early and hidden damage stages. Considering the dispersion of MMM data, the K vs statistical law is investigated, which shows that K vs obeys Gaussian distribution. So K vs is the suitable MMM parameter to establish reliability model of welded joints. At last, the original quantitative MMM reliability model is first presented based on the improved stress strength interference theory. It is shown that the reliability degree R gradually decreases with the decreasing of the residual life ratio T, and the maximal error between prediction reliability degree R 1 and verification reliability degree R 2 is 9.15%. This presented method provides a novel tool of reliability testing and evaluating in practical engineering for welded joints.

  18. The neural effects of positively and negatively re-experiencing mental fatigue sensation: a magnetoencephalography study.

    PubMed

    Ishii, Akira; Ishizuka, Takuya; Muta, Yuki; Tanaka, Masaaki; Yamano, Emi; Watanabe, Yasuyoshi

    2018-06-01

    Fatigue sensation is an essential biological alarm that urges us to take rest to avoid disrupting homeostasis and thus plays an important role in maintaining well-being. However, there are situations in which the anticipation of unpleasant fatigue sensation undesirably reduces motivation for activity. The aim of this study was to examine whether thinking positively about the fatigue sensation would increase motivation to accomplish the workload. Fourteen healthy male volunteers participated in this study and performed a two-back test for 30 min to induce mental fatigue sensation. After their subjective level of fatigue had recovered to the baseline level, they re-experienced the fatigue sensation experienced in the two-back test positively, negatively, and without any modification (i.e., re-experienced the fatigue sensation as it was). The level of motivation to perform another two-back test they felt during the re-experiencing was assessed. The neural activity related to the re-experiencing was recorded using magnetoencephalography. The level of the motivation to perform another two-back test was increased by positively re-experiencing the fatigue sensation. The increase in delta band power in Brodmann area 7 was positively associated with the increase in motivation. These results show that positive thinking about fatigue sensation can enhance motivation and suggest that this enhanced motivation may have some effects on visual attention system.

  19. Validity, Reliability, and Performance Determinants of a New Job-Specific Anaerobic Work Capacity Test for the Norwegian Navy Special Operations Command.

    PubMed

    Angeltveit, Andreas; Paulsen, Gøran; Solberg, Paul A; Raastad, Truls

    2016-02-01

    Operators in Special Operation Forces (SOF) have a particularly demanding profession where physical and psychological capacities can be challenged to the extremes. The diversity of physical capacities needed depend on the mission. Consequently, tests used to monitor SOF operators' physical fitness should cover a broad range of physical capacities. Whereas tests for strength and aerobic endurance are established, there is no test for specific anaerobic work capacity described in the literature. The purpose of this study was therefore to evaluate the reliability, validity, and to identify performance determinants of a new test developed for testing specific anaerobic work capacity in SOF operators. Nineteen active young students were included in the concurrent validity part of the study. The students performed the evacuation (EVAC) test 3 times and the results were compared for reliability and with performance in the Wingate cycle test, 300-m sprint, and a maximal accumulated oxygen deficit (MAOD) test. In part II of the study, 21 Norwegian Navy Special Operations Command operators conducted the EVAC test, anthropometric measurements, a dual x-ray absorptiometry scan, leg press, isokinetic knee extensions, maximal oxygen uptake test, and countermovement jump (CMJ) test. The EVAC test showed good reliability after 1 familiarization trial (intraclass correlation = 0.89; coefficient of variance = 3.7%). The EVAC test correlated well with the Wingate test (r = -0.68), 300-m sprint time (r = 0.51), and 300-m mean power (W) (r = -0.67). No significant correlation was found with the MAOD test. In part II of the study, height, body mass, lean body mass, isokinetic knee extension torque, maximal oxygen uptake, and maximal power in a CMJ was significantly correlated with performance in the EVAC test. The EVAC test is a reliable and valid test for anaerobic work capacity for SOF operators, and muscle mass, leg strength, and leg power seem to be the most important determinants of performance.

  20. Verb-based versus class-based accounts of actionality effects in children's comprehension of passives.

    PubMed

    Gordon, P; Chafetz, J

    1990-09-01

    Several studies have shown that children perform worse on tests of passive comprehension when the verb is non-actional than when it is actional. Most existing accounts focus on the semantic characteristics of the class of non-action verbs in explaining this difference. An alternative is a "verb-based" account in which passives are initially learned verb by verb, and children hear fewer non-actional passives in their language input. An analysis of the passives heard by Adam, Eve and Sarah (Brown, 1973) found more actional than non-actional passives, consistent with the verb-based account. In a second study, children tested for passive comprehension were re-tested a week later. The verb-based account predicts that children should show a consistent pattern of responses for individual verbs on test and re-test. Such consistency was found, with some inconsistency due to improvement over the re-test. Further analyses showed no effects of affectedness in explaining children's problems with passives. Finally, we discuss whether a mixed model containing both verb-based and class-based mechanisms is required to explain the actionality effects.

  1. Arm cranking versus wheelchair propulsion for testing aerobic fitness in children with spina bifida who are wheelchair dependent.

    PubMed

    Bloemen, Manon A T; de Groot, Janke F; Backx, Frank J G; Westerveld, Rosalyne A; Takken, Tim

    2015-05-01

    To determine the best test performance and feasibility using a Graded Arm Cranking Test vs a Graded Wheelchair Propulsion Test in young people with spina bifida who use a wheelchair, and to determine the reliability of the best test. Validity and reliability study. Young people with spina bifida who use a wheelchair. Physiological responses were measured during a Graded Arm Cranking Test and a Graded Wheelchair Propulsion Test using a heart rate monitor and calibrated mobile gas analysis system (Cortex Metamax). For validity, peak oxygen uptake (VO2peak) and peak heart rate (HRpeak) were compared using paired t-tests. For reliability, the intra-class correlation coefficients, standard error of measurement, and standard detectable change were calculated. VO2peak and HRpeak were higher during wheelchair propulsion compared with arm cranking (23.1 vs 19.5 ml/kg/min, p = 0.11; 165 vs 150 beats/min, p < 0.05). Reliability of wheelchair propulsion showed high intra-class correlation coefficients (ICCs) for both VO2peak (ICC = 0.93) and HRpeak (ICC = 0.90). This pilot study shows higher HRpeak and a tendency to higher VO2peak in young people with spina bifida who are using a wheelchair when tested during wheelchair propulsion compared with arm cranking. Wheelchair propulsion showed good reliability. We recommend performing a wheelchair propulsion test for aerobic fitness testing in this population.

  2. CPM Test-Retest Reliability: "Standard" vs "Single Test-Stimulus" Protocols.

    PubMed

    Granovsky, Yelena; Miller-Barmak, Adi; Goldstein, Oren; Sprecher, Elliot; Yarnitsky, David

    2016-03-01

    Assessment of pain inhibitory mechanisms using conditioned pain modulation (CPM) is relevant clinically in prediction of pain and analgesic efficacy. Our objective is to provide necessary estimates of intersession CPM reliability, to enable transformation of the CPM paradigm into a clinical tool. Two cohorts of young healthy subjects (N = 65) participated in two dual-session studies. In Study I, a Bath-Thermode CPM protocol was used, with hot water immersion and contact heat as conditioning- and test-stimuli, respectively, in a classical parallel CPM design introducing test-stimulus first, and then the conditioning- and repeated test-stimuli in parallel. Study II consisted of two CPM protocols: 1) Two-Thermodes, one for each of the stimuli, in the same parallel design as above, and 2) single test-stimulus (STS) protocol with a single administration of a contact heat test-stimulus, partially overlapped in time by a remote shorter contact heat as conditioning stimulus. Test-retest reliability was assessed within 3-7 days. The STS-CPM had superior reliability intraclass correlation (ICC 2 ,: 1  = 0.59) over Bath-Thermode (ICC 2 ,: 1  = 0.34) or Two-Thermodes (ICC 2 ,: 1  = 0.21) protocols. The hand immersion conditioning pain had higher reliability than thermode pain (ICC 2 ,: 1  = 0.76 vs ICC 2 ,: 1  = 0.16). Conditioned test-stimulus pain scores were of good (ICC 2 ,: 1  = 0.62) or fair (ICC 2 ,: 1  = 0.43) reliability for the Bath-Thermode and the STS, respectively, but not for the Two-Thermodes protocol (ICC 2 ,: 1  = 0.20). The newly developed STS-CPM paradigm was more reliable than other CPM protocols tested here, and should be further investigated for its clinical relevance. It appears that large contact size of the conditioning-stimulus and use of single rather than dual test-stimulus pain contribute to augmentation of CPM reliability. © 2015 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  3. NASA Ares I Crew Launch Vehicle Upper Stage Overview

    NASA Technical Reports Server (NTRS)

    Davis, Daniel J.

    2008-01-01

    By incorporating rigorous engineering practices, innovative manufacturing processes and test techniques, a unique multi-center government/contractor partnership, and a clean-sheet design developed around the primary requirements for the International Space Station (ISS) and Lunar missions, the Upper Stage Element of NASA's Crew Launch Vehicle (CLV), the "Ares I," is a vital part of the Constellation Program's transportation system. Constellation's exploration missions will include Ares I and Ares V launch vehicles required to place crew and cargo in low-Earth orbit (LEO), crew and cargo transportation systems required for human space travel, and transportation systems and scientific equipment required for human exploration of the Moon and Mars. Early Ares I configurations will support ISS re-supply missions. A self-supporting cylindrical structure, the Ares I Upper Stage will be approximately 84' long and 18' in diameter. The Upper Stage Element is being designed for increased supportability and increased reliability to meet human-rating requirements imposed by NASA standards. The design also incorporates state-of-the-art materials, hardware, design, and integrated logistics planning, thus facilitating a supportable, reliable, and operable system. With NASA retiring the Space Shuttle fleet in 2010, the success of the Ares I Project is essential to America's continued leadership in space. The first Ares I test flight, called Ares 1-X, is scheduled for 2009. Subsequent test flights will continue thereafter, with the first crewed flight of the Crew Exploration Vehicle (CEV), "Orion," planned for no later than 2015. Crew transportation to the ISS will follow within the same decade, and the first Lunar excursion is scheduled for the 2020 timeframe.

  4. NASA Ares I Crew Launch Vehicle Upper Stage Overview

    NASA Technical Reports Server (NTRS)

    McArthur, J. Craig

    2008-01-01

    By incorporating rigorous engineering practices, innovative manufacturing processes and test techniques, a unique multi-center government/contractor partnership, and a clean-sheet design developed around the primary requirements for the International Space Station (ISS) and Lunar missions, the Upper Stage Element of NASA's Crew Launch Vehicle (CLV), the "Ares I," is a vital part of the Constellation Program's transportation system. Constellation's exploration missions will include Ares I and Ares V launch vehicles required to place crew and cargo in low-Earth orbit (LEO), crew and cargo transportation systems required for human space travel, and transportation systems and scientific equipment required for human exploration of the Moon and Mars. Early Ares I configurations will support ISS re-supply missions. A self-supporting cylindrical structure, the Ares I Upper Stage will be approximately 84' long and 18' in diameter. The Upper Stage Element is being designed for increased supportability and increased reliability to meet human-rating requirements imposed by NASA standards. The design also incorporates state-of-the-art materials, hardware, design, and integrated logistics planning, thus facilitating a supportable, reliable, and operable system. With NASA retiring the Space Shuttle fleet in 2010, the success of the Ares I Project is essential to America's continued leadership in space. The first Ares I test flight, called Ares I-X, is scheduled for 2009. Subsequent test flights will continue thereafter, with the first crewed flight of the Crew Exploration Vehicle (CEV), "Orion," planned for no later than 2015. Crew transportation to the ISS will follow within the same decade, and the first Lunar excursion is scheduled for the 2020 timeframe.

  5. Development and piloting the Woman Centred Care Scale (WCCS).

    PubMed

    Brady, Susannah; Bogossian, Fiona; Gibbons, Kristen

    2017-06-01

    In midwifery we espouse a woman centred care approach to practice, yet in midwifery education no valid instrument exists with which to measure the performance of these behaviours in midwifery students. To develop and validate an instrument to measure woman centred care behaviours in midwifery students. We identified four core concepts; woman's sphere, holism, self-determination and the shared power relationship. We mapped 18 individual descriptive care behaviours (from the Australian National Competency Standards for the Midwife) to these concepts to create an instrument to articulate and measure care behaviours that are specifically woman centred. Review by expert midwifery clinicians ensured face, content and construct validity of the scale and predictive validity and reliability were tested in a simulated learning environment. Midwifery students were video recorded performing a clinical skill and the videos were reviewed and rated by two expert clinicians who assessed the woman centred care behaviours demonstrated by the students (n=69). Test and re-test reliability of the instrument was high for each of the individual raters (Kappa 0.946 and 0.849 respectively p<0.001). However, when raters were compared there were differences between their scores suggesting variation in their expectations of woman centred care behaviours (Kappa 0.470, p<0.001). Midwifery students who had repeated exposures to higher levels of simulation fidelity demonstrated higher levels of woman centred care behaviours. The WCCS has implications for education and the wider midwifery profession in recognising and maintaining practice consistent with the underlying philosophy of woman centred care. Copyright © 2016 Australian College of Midwives. Published by Elsevier Ltd. All rights reserved.

  6. Interhemispheric Inhibition Measurement Reliability in Stroke: A Pilot Study

    PubMed Central

    Cassidy, Jessica M.; Chu, Haitao; Chen, Mo; Kimberley, Teresa J.; Carey, James R.

    2016-01-01

    Objective Reliable transcranial magnetic stimulation (TMS) measures for probing corticomotor excitability are important when assessing the physiological effects of non-invasive brain stimulation. The primary objective of this study was to examine test-retest reliability of an interhemispheric inhibition (IHI) index measurement in stroke. Materials and Methods Ten subjects with chronic stroke (≥ 6 months) completed two IHI testing sessions per week for three weeks (six testing sessions total). A single investigator measured IHI in the contra- to-ipsilesional primary motor cortex direction and in the opposite direction using bilateral paired-pulse TMS. Weekly sessions were separated by 24 hours with a 1-week washout period separating testing weeks. To determine if motor-evoked potential (MEP) quantification method affected measurement reliability, IHI indices computed from both MEP amplitude and area responses were found. Reliability was assessed with two-way, mixed intraclass correlation coefficients (ICC(3,k)). Standard error of measurement and minimal detectable difference statistics were also determined. Results With the exception of the initial testing week, IHI indices measured in the contra-to-ipsilesional hemisphere direction demonstrated moderate to excellent reliability (ICC = 0.725 – 0.913). Ipsi-to-contralesional IHI indices depicted poor or invalid reliability estimates throughout the three-week testing duration (ICC= −1.153 – 0.105). The overlap of ICC 95% confidence intervals suggested that IHI indices using MEP amplitude vs. area measures did not differ with respect to reliability. Conclusions IHI indices demonstrated varying magnitudes of reliability irrespective of MEP quantification method. Several strategies for improving IHI index measurement reliability are discussed. PMID:27333364

  7. Bruininks-Oseretsky Test of Motor Proficiency: Further Verification with 3- to 5- yr. -old Children.

    ERIC Educational Resources Information Center

    Beitel, Patricia A.; Mead, Barbara J.

    1982-01-01

    The Bruininks-Oseretsky Test of Motor Proficiency was evaluated to determine test-retest reliability and if there were presensitizing effects at retest for four- to five-year olds. Test reliability was significantly high. No significant test sensitization of the short form to retesting with the short form or subtests was found. (Author/RD)

  8. Machine on Trial

    DTIC Science & Technology

    2012-06-01

    executed a concerted effort to employ reliability standards and testing from the design phase through fielding. Reliability programs remain standard...performed flight test engineer duties on several developmental flight test programs and served as Chief Engineer for a flight test squadron. Major...Quant is an acquisition professional with over 250 flight test hours in various aircraft, including the F-16, Airborne Laser, and HH-60. She holds a

  9. Transonic Blunt Body Aerodynamic Coefficients Computation

    NASA Astrophysics Data System (ADS)

    Sancho, Jorge; Vargas, M.; Gonzalez, Ezequiel; Rodriguez, Manuel

    2011-05-01

    In the framework of EXPERT (European Experimental Re-entry Test-bed) accurate transonic aerodynamic coefficients are of paramount importance for the correct trajectory assessment and parachute deployment. A combined CFD (Computational Fluid Dynamics) modelling and experimental campaign strategy was selected to obtain accurate coefficients. A preliminary set of coefficients were obtained by CFD Euler inviscid computation. Then experimental campaign was performed at DNW facilities at NLR. A profound review of the CFD modelling was done lighten up by WTT results, aimed to obtain reliable values of the coefficients in the future (specially the pitching moment). Study includes different turbulence modelling and mesh sensitivity analysis. Comparison with the WTT results is explored, and lessons learnt are collected.

  10. Contact allergy to chlorhexidine in a tertiary dermatology clinic in Denmark.

    PubMed

    Opstrup, Morten S; Johansen, Jeanne D; Zachariae, Claus; Garvey, Lene H

    2016-01-01

    Chlorhexidine is a widely used disinfectant in the healthcare setting and in cosmetic products. A high prevalence of chlorhexidine contact allergy was reported in Denmark in the 1980s (2.0-5.4% of patients patch tested). It is unknown whether the prevalence is still high, which products cause the contact allergy, and whether accidental re-exposure occurs in some patients. To estimate the prevalence of chlorhexidine contact allergy in a tertiary dermatology clinic in Denmark; to investigate whether patch testing with both chlorhexidine diacetate and chlorhexidine digluconate is necessary; to investigate how many patients have combined immediate-type allergy and contact allergy; and to identify which products cause chlorhexidine contact allergy, and whether patients are accidentally re-exposed. This was a retrospective study including all patients patch tested with chlorhexidine during 2003-2013 at the Department of Dermato-Allergology at Copenhagen University Hospital Gentofte (n = 8497). All patients with a positive patch test reaction to chlorhexidine were sent a questionnaire comprising questions about the cause of the allergy and re-exposure. Overall, 1.0% (n = 82) of all patients patch tested with chlorhexidine were positive. A decrease in the prevalence was observed over time, most likely because of lowering of the test concentration from 1.0 to 0.5% in 2008. Of the 82 patients, 28 (0.3%) had positive test reactions to both chlorhexidine salts, 43 (0.5%) had a positive test reaction only to chlorhexidine diacetate, and 11 (0.1%) had a positive test reaction to chlorhexidine digluconate. Three patients were both patch test-positive and prick test-positive. A known cause of the allergy was reported by 19 patients (40%) in the questionnaire: the products used in the healthcare setting were mainly reported, but some reported cosmetic products. Accidental re-exposure was reported by 15 patients (32%), of whom 13 reported symptoms. The prevalence of chlorhexidine contact allergy does not seem to be higher in Denmark than in other European countries. Patch testing with both chlorhexidine diacetate and chlorhexidine digluconate may be beneficial. Testing for immediate-type allergy in patients with a positive patch test reaction to chlorhexidine is recommended. Chlorhexidine-containing products used in the healthcare setting and in cosmetics are potential causes of sensitization and allergy. Re-exposure is common, highlighting the fact that patients and healthcare personnel need to be well informed about possible sources of exposure. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Reliability of cognitive tests of ELSA-Brasil, the brazilian longitudinal study of adult health

    PubMed Central

    Batista, Juliana Alves; Giatti, Luana; Barreto, Sandhi Maria; Galery, Ana Roscoe Papini; Passos, Valéria Maria de Azeredo

    2013-01-01

    Cognitive function evaluation entails the use of neuropsychological tests, applied exclusively or in sequence. The results of these tests may be influenced by factors related to the environment, the interviewer or the interviewee. OBJECTIVES We examined the test-retest reliability of some tests of the Brazilian version from the Consortium to Establish a Registry for Alzheimer's disease. METHODS The ELSA-Brasil is a multicentre study of civil servants (35-74 years of age) from public institutions across six Brazilian States. The same tests were applied, in different order of appearance, by the same trained and certified interviewer, with an approximate 20-day interval, to 160 adults (51% men, mean age 52 years). The Intraclass Correlation Coefficient (ICC) was used to assess the reliability of the measures; and a dispersion graph was used to examine the patterns of agreement between them. RESULTS We observed higher retest scores in all tests as well as a shorter test completion time for the Trail Making Test B. ICC values for each test were as following: Word List Learning Test (0.56), Word Recall (0.50), Word Recognition (0.35), Phonemic Verbal Fluency Test (VFT, 0.61), Semantic VFT (0.53) and Trail B (0.91). The Bland-Altman plot showed better correlation of executive function (VFT and Trail B) than of memory tests. CONCLUSIONS Better performance in retest may reflect a learning effect, and suggest that retest should be repeated using alternate forms or after longer periods. In this sample of adults with high schooling level, reliability was only moderate for memory tests whereas the measurement of executive function proved more reliable. PMID:29213860

  12. FUNCTIONAL PERFORMANCE TESTING OF THE HIP IN ATHLETES: A SYSTEMATIC REVIEW FOR RELIABILITY AND VALIDITY

    PubMed Central

    Martin, RobRoy L.

    2012-01-01

    Purpose/Background: The purpose of this study was to systematically review the literature for functional performance tests with evidence of reliability and validity that could be used for a young, athletic population with hip dysfunction. Methods: A search of PubMed and SPORTDiscus databases were performed to identify movement, balance, hop/jump, or agility functional performance tests from the current peer-reviewed literature used to assess function of the hip in young, athletic subjects. Results: The single-leg stance, deep squat, single-leg squat, and star excursion balance tests (SEBT) demonstrated evidence of validity and normative data for score interpretation. The single-leg stance test and SEBT have evidence of validity with association to hip abductor function. The deep squat test demonstrated evidence as a functional performance test for evaluating femoroacetabular impingement. Hop/Jump tests and agility tests have no reported evidence of reliability or validity in a population of subjects with hip pathology. Conclusions: Use of functional performance tests in the assessment of hip dysfunction has not been well established in the current literature. Diminished squat depth and provocation of pain during the single-leg balance test have been associated with patients diagnosed with FAI and gluteal tendinopathy, respectively. The SEBT and single-leg squat tests provided evidence of convergent validity through an analysis of kinematics and muscle function in normal subjects. Reliability of functional performance tests have not been established on patients with hip dysfunction. Further study is needed to establish reliability and validity of functional performance tests that can be used in a young, athletic population with hip dysfunction. Level of Evidence: 2b (Systematic Review of Literature) PMID:22893860

  13. Two-colour chewing gum mixing ability test for evaluating masticatory performance in children with mixed dentition: validity and reliability study.

    PubMed

    Kaya, M S; Güçlü, B; Schimmel, M; Akyüz, S

    2017-11-01

    The unappealing taste of the chewing material and the time-consuming repetitive task in masticatory performance tests using artificial foodstuff may discourage children from performing natural chewing movements. Therefore, the aim was to determine the validity and reliability of a two-colour chewing gum mixing ability test for masticatory performance (MP) assessment in mixed dentition children. Masticatory performance was tested in two groups: systemically healthy fully dentate young adults and children in mixed dentition. Median particle size was assessed using a comminution test, and a two-colour chewing gum mixing ability test was applied for MP analysis. Validity was tested with Pearson correlation, and reliability was tested with intra-class correlation coefficient, Pearson correlation and Bland-Altman plots. Both comminution and two-colour chewing gum mixing ability tests revealed statistically significant MP differences between children (n = 25) and adults (n = 27, both P < 0·01). Pearson correlation between comminution and two-colour chewing gum mixing ability tests was positive and significant (r = 0·418, P = 0·002). Correlations for interobserver reliability and test-retest values were significant (r = 0·990, P = 0·0001 and r = 0·995, P = 0·0001). Although both methods could discriminate MP differences, the comminution test detected these differences generally in a wider range compared to two-colour chewing gum mixing ability test. However, considering the high reliability of the results, the two-colour chewing gum mixing ability test can be used to assess masticatory performance in children, especially at non-clinical settings. © 2017 John Wiley & Sons Ltd.

  14. On-clip high frequency reliability and failure test structures

    DOEpatents

    Snyder, E.S.; Campbell, D.V.

    1997-04-29

    Self-stressing test structures for realistic high frequency reliability characterizations. An on-chip high frequency oscillator, controlled by DC signals from off-chip, provides a range of high frequency pulses to test structures. The test structures provide information with regard to a variety of reliability failure mechanisms, including hot-carriers, electromigration, and oxide breakdown. The system is normally integrated at the wafer level to predict the failure mechanisms of the production integrated circuits on the same wafer. 22 figs.

  15. Cognitive Decline in Down Syndrome: A Validity/Reliability Study of the Test for Severe Impairment.

    ERIC Educational Resources Information Center

    Cosgrave, Mary P.; McCarron, Mary; Anderson, Mary; Tyrrell, Janette; Gill, Michael; Lawlor, Brian A.

    1998-01-01

    The utility of the Test for Severe Impairment was studied with 60 older persons who had Down Syndrome. Construct validity, test-retest reliability, and interrater reliability were established for the full study group and for subgroups based on degree of mental retardation and dementia status. Some possible applications and limitations of the test…

  16. Effects of Scoring by Section and Independent Scorers' Patterns on Scorer Reliability in Biology Essay Tests

    ERIC Educational Resources Information Center

    Ebuoh, Casmir N.; Ezeudu, S. A.

    2015-01-01

    The study investigated the effects of scoring by section, use of independent scorers and conventional patterns on scorer reliability in Biology essay tests. It was revealed from literature review that conventional pattern of scoring all items at a time in essay tests had been criticized for not being reliable. The study was true experimental study…

  17. Assessing Reliability of Two Versions of Vocabulary Levels Tests in Iranian Context

    ERIC Educational Resources Information Center

    Bayazidi, Aso; Saeb, Fateme

    2017-01-01

    This study examined the equivalence and reliability of the two versions of the Vocabulary Levels Test in an Iranian context. This study was motivated by the fact that the Vocabulary Levels test is increasingly being used in Iran for both research and pedagogical purposes without having been checked for validity and reliability in this context. The…

  18. Reliability Estimation When a Test Is Split into Two Parts of Unknown Effective Length.

    ERIC Educational Resources Information Center

    Feldt, Leonard S.

    2002-01-01

    Considers the situation in which content or administrative considerations limit the way in which a test can be partitioned to estimate the internal consistency reliability of the total test score. Demonstrates that a single-valued estimate of the total score reliability is possible only if an assumption is made about the comparative size of the…

  19. Reliability of the Swedish version of the Exercise Self-Efficacy Scale (S-ESES): a test-retest study in adults with neurological disease.

    PubMed

    Ahlström, Isabell; Hellström, Karin; Emtner, Margareta; Anens, Elisabeth

    2015-03-01

    To examine the test-retest reliability of the Swedish translated version of the Exercise Self-Efficacy Scale (S-ESES) in people with neurological disease and to examine internal consistency. Test-retest study. A total of 30 adults with neurological diseases including: Parkinson's disease; Multiple Sclerosis; Cervical Dystonia; and Charcot-Marie-Tooth disease. The S-ESES was sent twice by surface mail. Completion interval mean was 16 days apart. Weighted kappa, intraclass correlation coefficient 2,1 [ICC (2,1)], standard error of measurement (SEM), also expressed as a percentage value (SEM%), and Cronbach's alpha were calculated. The relative reliability of the test-retest results showed substantial agreement measured using weighted kappa (MD = 0.62) and a very high-reliability ICC (2,1) (0.92). Absolute reliability measured using SEM was 5.3 and SEM% was 20.7. Excellent internal consistency was shown, with an alpha coefficient of 0.91 (test 1) and 0.93 (test 2). The S-ESES is recommended for use in research and in clinical work for people with neurological diseases. The low-absolute reliability, however, indicates a limited ability to measure changes on an individual level.

  20. Reliability of temporal summation and diffuse noxious inhibitory control

    PubMed Central

    Cathcart, Stuart; Winefield, Anthony H; Rolan, Paul; Lushington, Kurt

    2009-01-01

    BACKGROUND: The test-retest reliability of temporal summation (TS) and diffuse noxious inhibitory control (DNIC) has not been reported to date. Establishing such reliability would support the possibility of future experimental studies examining factors affecting TS and DNIC. Similarly, the use of manual algometry to induce TS, or an occlusion cuff to induce DNIC of TS to mechanical stimuli, has not been reported to date. Such devices may offer a simpler method than current techniques for inducing TS and DNIC, affording assessment at more anatomical locations and in more varied research settings. METHOD: The present study assessed the test-retest reliability of TS and DNIC using the above techniques. Sex differences on these measures were also investigated. RESULTS: Repeated measures ANOVA indicated successful induction of TS and DNIC, with no significant differences across test-retest occasions. Sex effects were not significant for any measure or interaction. Intraclass correlations indicated high test-retest reliability for all measures; however, there was large interindividual variation between test and retest measurements. CONCLUSION: The present results indicate acceptable within-session test-retest reliability of TS and DNIC. The results support the possibility of future experimental studies examining factors affecting TS and DNIC. PMID:20011713

  1. Test-retest reliability of the scale of participation in organized activities among adolescents in the Czech Republic and Slovakia.

    PubMed

    Bosakova, Lucia; Kolarcik, Peter; Bobakova, Daniela; Sulcova, Martina; Van Dijk, Jitse P; Reijneveld, Sijmen A; Geckova, Andrea Madarasova

    2016-04-01

    Participation in organized activities is related with a range of positive outcomes, but the way such participation is measured has not been scrutinized. Test-retest reliability as an important indicator of a scale's reliability has been assessed rarely and for "The scale of participation in organized activities" lacks completely. This test-retest study is based on the Health Behaviour in School-aged Children study and is consistent with its methodology. We obtained data from 353 Czech (51.9 % boys) and 227 Slovak (52.9 % boys) primary school pupils, grades five and nine, who participated in this study in 2013. We used Cohen's kappa statistic and single measures of the intraclass correlation coefficient to estimate the test-retest reliability of all selected items in the sample, stratified by gender, age and country. We mostly observed a large correlation between the test and retest in all of the examined variables (κ ranged from 0.46 to 0.68). Test-retest reliability of the sum score of individual items showed substantial agreement (ICC = 0.64). The scale of participation in organized activities has an acceptable level of agreement, indicating good reliability.

  2. Estimation of Reliability Coefficients Using the Test Information Function and Its Modifications.

    ERIC Educational Resources Information Center

    Samejima, Fumiko

    1994-01-01

    The reliability coefficient is predicted from the test information function (TIF) or two modified TIF formulas and a specific trait distribution. Examples illustrate the variability of the reliability coefficient across different trait distributions, and results are compared with empirical reliability coefficients. (SLD)

  3. A novel comprehensive evaluation platform to assess nanoparticle toxicity in vitro

    NASA Astrophysics Data System (ADS)

    Hirsch, C.; Kaiser, J.-P.; Wessling, F.; Fischer, K.; Roesslein, M.; Wick, P.; Krug, H. F.

    2011-07-01

    The amount of engineered nanomaterials (ENM) is constantly increasing. Their unique properties, compared to their bulk counterparts, render them suitable for various applications in many areas of life. Hence, nanomaterials appear in a variety of different consumer products leading to the exposure of human beings and the environment during their lifecycle. Even though results on biological effects of ENM are available, harmonized and validated test systems are still missing. One major problem concerning the reliable and robust toxicity testing arises from interactions of ENM with different assay systems. Modifications or damage to DNA can have fatal consequences, such as the formation of tumor cells and hence carcinogenesis. Therefore we focused on the re-evaluation of two genotoxicity assays concerning their nanomaterial compatibility; namely the cytokinesis-block micronucleus cytome assay (MN-assay) and the alkaline single cell gel electorphoresis assay (comet assay). We demonstrate the interference of ENM agglomerates with the read-out of both assays and discuss possibilities how to acquire relevant genotoxicity data.

  4. Generating high Reynolds-number flows.

    NASA Technical Reports Server (NTRS)

    Russell, D. A.

    1972-01-01

    Present test facilities are seriously limited regarding investigations involving high Reynolds numbers due to financial considerations. Quasi-steady testing facilities offer a practical immediate solution to the problem of high-Re testing. A familiar example is the blowdown wind tunnel, but even more flexibility and economy may be provided by using shock-tube devices. The Ludwieg tube is the shock-tube device most often proposed as a means of generating high-Re flows. Two-stage nozzles may be used with a Ludwieg tube. Quasi-steady facilities will be useful only if the available test time exceeds that required to establish steady flow.

  5. Preparation and properties of polytetrafluoroethylene impregnated with rhenium oxides

    NASA Technical Reports Server (NTRS)

    Leibecki, H. F.; Easter, R. W.

    1973-01-01

    The results of tests carried out to determine the properties of polytetrafluorethylene (PTFE) impregnated with rhenium oxides are presented. The tests included measurement of physical properties of the impregnated material and investigation of the effects of preparation process variables. Based on the latter tests a mechanism to describe the permeation process is postulated which identifies the rate controlling step to be diffusion of ReF6 molecules into the solid during the initial ReF6 soak. Physical property tests indicated that the electronic conductance is increased by many orders of magnitude while the desirable properties of the PTFE remain virtually unchanged.

  6. Measuring social alienation in adolescence: translation and validation of the Jessor and Jessor Social Alienation Scale.

    PubMed

    Safipour, Jalal; Tessma, Mesfin Kassaye; Higginbottom, Gina; Emami, Azita

    2010-12-01

    The objective of the study is to translate and examine the reliability and validity of the Jessor and Jessor Social Alienation Scale for use in a Swedish context. The study involved four phases of testing: (1) Translation and back-translation; (2) a pilot test to evaluate the translation; (3) reliability testing; and (4) a validity test. Main participants of this study were 446 students (Age = 15-19, SD = 1.01, Mean = 17). Results from the reliability test showed high internal consistency and stability. Face, content and construct validity were demonstrated using experts and confirmatory factor analysis. The results of testing the Swedish version of the alienation scale revealed an acceptable level of reliability and validity, and is appropriate for use in the Swedish context. © 2010 The Authors. Scandinavian Journal of Psychology © 2010 The Scandinavian Psychological Associations.

  7. System reliability of randomly vibrating structures: Computational modeling and laboratory testing

    NASA Astrophysics Data System (ADS)

    Sundar, V. S.; Ammanagi, S.; Manohar, C. S.

    2015-09-01

    The problem of determination of system reliability of randomly vibrating structures arises in many application areas of engineering. We discuss in this paper approaches based on Monte Carlo simulations and laboratory testing to tackle problems of time variant system reliability estimation. The strategy we adopt is based on the application of Girsanov's transformation to the governing stochastic differential equations which enables estimation of probability of failure with significantly reduced number of samples than what is needed in a direct simulation study. Notably, we show that the ideas from Girsanov's transformation based Monte Carlo simulations can be extended to conduct laboratory testing to assess system reliability of engineering structures with reduced number of samples and hence with reduced testing times. Illustrative examples include computational studies on a 10-degree of freedom nonlinear system model and laboratory/computational investigations on road load response of an automotive system tested on a four-post test rig.

  8. 29 CFR 1926.1427 - Operator qualification and certification.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... determination that industry recognized criteria for written testing materials, practical examinations, test... tests that: (A) Assess the operator applicant regarding, at a minimum, the knowledge and skills listed... an operator applicant fails a test or is decertified. (iv) Have testing procedures for re...

  9. 29 CFR 1926.1427 - Operator qualification and certification.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... determination that industry recognized criteria for written testing materials, practical examinations, test... tests that: (A) Assess the operator applicant regarding, at a minimum, the knowledge and skills listed... an operator applicant fails a test or is decertified. (iv) Have testing procedures for re...

  10. 29 CFR 1926.1427 - Operator qualification and certification.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... determination that industry recognized criteria for written testing materials, practical examinations, test... tests that: (A) Assess the operator applicant regarding, at a minimum, the knowledge and skills listed... an operator applicant fails a test or is decertified. (iv) Have testing procedures for re...

  11. 29 CFR 1926.1427 - Operator qualification and certification.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... determination that industry recognized criteria for written testing materials, practical examinations, test... tests that: (A) Assess the operator applicant regarding, at a minimum, the knowledge and skills listed... an operator applicant fails a test or is decertified. (iv) Have testing procedures for re...

  12. Advanced Concept

    NASA Image and Video Library

    2008-02-15

    THIS IS A MODEL TEST OF THE 1ST STAGE RE-ENTRY. HEAT TESTING OF A 3% MODEL TO SUPPORT THE ARES/CLV FIRST STAGE RE-ENTRY. THIS OCCURRED AT ARNOLD AIR FORCE BASE, TENNESSEE IN SUPPORT OF THE CONSTELLATION/ARES PROJECT. THIS IMAGE IS EXTRACTED FROM A HIGH DEFINITION VIDEO FILE AND IS THE HIGHEST RESOLUTION AVAILABLE.

  13. Continued effects of context reinstatement in recognition.

    PubMed

    Hanczakowski, Maciej; Zawadzka, Katarzyna; Macken, Bill

    2015-07-01

    The context reinstatement effect refers to the enhanced memory performance found when the context information paired with a target item at study is re-presented at test. Here we investigated the consequences of the way that context information is processed in such a setting that gives rise to its beneficial effect on item recognition memory. Specifically, we assessed whether reinstating context in a recognition test facilitates subsequent memory for this context, beyond the facilitation conferred by presentation of the same context with a different study item. Reinstating the study context at test led to better accuracy in two-alternative forced choice recognition for target faces than did re-pairing those faces with another context encountered during the study phase. The advantage for reinstated over re-paired conditions occurred for both within-subjects (Exp. 1) and between-subjects (Exp. 2) manipulations. Critically, in a subsequent recognition test for the contexts themselves, contexts that had previously served in the reinstated condition were recognized better than contexts that had previously served in the re-paired context condition. This constitutes the first demonstration of continuous effects of context reinstatement on memory for context.

  14. Development and reliability testing of the Worksite and Energy Balance Survey.

    PubMed

    Hoehner, Christine M; Budd, Elizabeth L; Marx, Christine M; Dodson, Elizabeth A; Brownson, Ross C

    2013-01-01

    Worksites represent important venues for health promotion. Development of psychometrically sound measures of worksite environments and policy supports for physical activity and healthy eating are needed for use in public health research and practice. Assess the test-retest reliability of the Worksite and Energy Balance Survey (WEBS), a self-report instrument for assessing perceptions of worksite supports for physical activity and healthy eating. The WEBS included items adapted from existing surveys or new items on the basis of a review of the literature and expert review. Cognitive interviews among 12 individuals were used to test the clarity of items and further refine the instrument. A targeted random-digit-dial telephone survey was administered on 2 occasions to assess test-retest reliability (mean days between time periods = 8; minimum = 5; maximum = 14). Five Missouri census tracts that varied by racial-ethnic composition and walkability. Respondents included 104 employed adults (67% white, 64% women, mean age = 48.6 years). Sixty-three percent were employed at worksites with less than 100 employees, approximately one-third supervised other people, and the majority worked a regular daytime shift (75%). Test-retest reliability was assessed using Spearman correlations for continuous variables, Cohen's κ statistics for nonordinal categorical variables, and 1-way random intraclass correlation coefficients for ordinal categorical variables. Test-retest coefficients ranged from 0.41 to 0.97, with 80% of items having reliability coefficients of more than 0.6. Items that assessed participation in or use of worksite programs/facilities tended to have lower reliability. Reliability of some items varied by gender, obesity status, and worksite size. Test-retest reliability and internal consistency for the 5 scales ranged from 0.84 to 0.94 and 0.63 to 0.84, respectively. The WEBS items and scales exhibited sound test-retest reliability and may be useful for research and surveillance. Further evaluation is needed to document the validity of the WEBS and associations with energy balance outcomes.

  15. Extreme sensitivity in Thermoacoustics

    NASA Astrophysics Data System (ADS)

    Juniper, Matthew

    2017-11-01

    In rocket engines and gas turbines, fluctuations in the heat release rate can lock in to acoustic oscillations and grow catastrophically. Nine decades of engine development have shown that these oscillations are difficult to predict but can usually be eliminated with small ad hoc design changes. The difficulty in prediction arises because the oscillations' growth rate is exceedingly sensitive to parameters that cannot always be measured or simulated reliably, which introduces severe systematic error into thermoacoustic models of engines. Passive control strategies then have to be devised through full scale engine tests, which can be ruinously expensive. For the Apollo F1 engine, for example, 2000 full-scale tests were required. Even today, thermoacoustic oscillations often re-appear unexpectedly at full engine test stage. Although the physics is well known, a novel approach to design is required. In this presentation, the parameters of a thermoacoustic model are inferred from many thousand automated experiments using inverse uncertainty quantification. The adjoint of this model is used to obtain cheaply the gradients of every unstable mode with respect to the model parameters. This gradient information is then used in an optimization algorithm to stabilize every thermoacoustic mode by subtly changing the geometry of the model.

  16. An ecologically valid performance-based social functioning assessment battery for schizophrenia.

    PubMed

    Shi, Chuan; He, Yi; Cheung, Eric F C; Yu, Xin; Chan, Raymond C K

    2013-12-30

    Psychiatrists pay more attention to the social functioning outcome of schizophrenia nowadays. How to evaluate the real world function among schizophrenia is a challenging task due to culture difference, there is no such kind of instrument in terms of the Chinese setting. This study aimed to report the validation of an ecologically valid performance-based everyday functioning assessment for schizophrenia, namely the Beijing Performance-based Functional Ecological Test (BJ-PERFECT). Fifty community-dwelling adults with schizophrenia and 37 healthy controls were recruited. Fifteen of the healthy controls were re-tested one week later. All participants were administered the University of California, San Diego, Performance-based Skill Assessment-Brief version (UPSA-B) and the MATRICS Consensus Cognitive Battery (MCCB). The finalized assessment included three subdomains: transportation, financial management and work ability. The test-retest and inter-rater reliabilities were good. The total score significantly correlated with the UPSA-B. The performance of individuals with schizophrenia was significantly more impaired than healthy controls, especially in the domain of work ability. Among individuals with schizophrenia, functional outcome was influenced by premorbid functioning, negative symptoms and neurocognition such as processing speed, visual learning and attention/vigilance. © 2013 Elsevier Ireland Ltd. All rights reserved.

  17. Keeping waived tests simple.

    PubMed

    2004-01-01

    Laboratories performing waived testing must follow the manufacturer's instructions as well as good laboratory practices to ensure that test results are reliable. Four things to concentrate on to maximize the performance and reliability of waived tests are to: 1. Read and follow the information found in the package inserts. 2. Follow the manufacturer's recommendations for running quality control. 3. Train staff members to perform tests correctly. 4. Follow established policies and procedures for patient testing in the practice.

  18. Development of an Agility Test for Badminton Players and Assessment of Its Validity and Test-Retest Reliability.

    PubMed

    Loureiro, Luiz de França Bahia; de Freitas, Paulo Barbosa

    2016-04-01

    Badminton requires open and fast actions toward the shuttlecock, but there is no specific agility test for badminton players with specific movements. To develop an agility test that simultaneously assesses perception and motor capacity and examine the test's concurrent and construct validity and its test-retest reliability. The Badcamp agility test consists of running as fast as possible to 6 targets placed on the corners and middle points of a rectangular area (5.6 × 4.2 m) from the start position located in the center of it, following visual stimuli presented in a luminous panel. The authors recruited 43 badminton players (17-32 y old) to evaluate concurrent (with shuttle-run agility test--SRAT) and construct validity and test-retest reliability. Results revealed that Badcamp presents concurrent and construct validity, as its performance is strongly related to SRAT (ρ = 0.83, P < .001), with performance of experts being better than nonexpert players (P < .01). In addition, Badcamp is reliable, as no difference (P = .07) and a high intraclass correlation (ICC = .93) were found in the performance of the players on 2 different occasions. The findings indicate that Badcamp is an effective, valid, and reliable tool to measure agility, allowing coaches and athletic trainers to evaluate players' athletic condition and training effectiveness and possibly detect talented individuals in this sport.

  19. Intersession reliability of self-selected and narrow stance balance testing in older adults.

    PubMed

    Riemann, Bryan L; Piersol, Kelsey

    2017-10-01

    Despite the common practice of using force platforms to assess balance of older adults, few investigations have examined the reliability of postural screening tests in this population. We sought to determine the test-retest reliability of self-selected and narrow stance balance testing with eyes open and eyes closed in healthy older adults. Thirty older adults (>65 years) completed 45 s trials of eyes open and eyes closed stability tests using self-selected and narrow stances on two separate days (1.9 ± .7 days). Average medial-lateral center of pressure velocity was computed. The ICC results ranged from .74 to .86, and no significant systematic changes (P < .05) occurred between the testing sessions for any of the tests. The standard error of measurement ranged from 15.9 to 23.6%. Reliability estimates were similar between the two stances and visual conditions assessed. Slightly higher coefficients were identified for the self-selected stances compared to the narrow stances under both visual conditions; however, there were negligible differences between the sessions. The within subject session-to-session variability provides a basis for further research to consider differences between fallers and non-fallers. Reliability for eyes open and closed balance testing using self-selected and narrow stances in older adults was established which should provide a foundation for the development of fall risk screening tests.

  20. Compilation, design tests: Energetic particles Satellite S-3 including design tests for S-3A, S-3B and S-3C

    NASA Technical Reports Server (NTRS)

    Ledoux, F. N.

    1973-01-01

    A compilation of engineering design tests which were conducted in support of the Energetic Particle Satellite S-3, S-3A, and S-3b programs. The purpose for conducting the tests was to determine the adequacy and reliability of the Energetic Particles Series of satellites designs. The various tests consisted of: (1) moments of inertia, (2) functional reliability, (3) component and structural integrity, (4) initiators and explosives tests, and (5) acceptance tests.

  1. Development and psychometric evaluation of an information literacy self-efficacy survey and an information literacy knowledge test.

    PubMed

    Tepe, Rodger; Tepe, Chabha

    2015-03-01

    To develop and psychometrically evaluate an information literacy (IL) self-efficacy survey and an IL knowledge test. In this test-retest reliability study, a 25-item IL self-efficacy survey and a 50-item IL knowledge test were developed and administered to a convenience sample of 53 chiropractic students. Item analyses were performed on all questions. The IL self-efficacy survey demonstrated good reliability (test-retest correlation = 0.81) and good/very good internal consistency (mean κ = .56 and Cronbach's α = .92). A total of 25 questions with the best item analysis characteristics were chosen from the 50-item IL knowledge test, resulting in a 25-item IL knowledge test that demonstrated good reliability (test-retest correlation = 0.87), very good internal consistency (mean κ = .69, KR20 = 0.85), and good item discrimination (mean point-biserial = 0.48). This study resulted in the development of three instruments: a 25-item IL self-efficacy survey, a 50-item IL knowledge test, and a 25-item IL knowledge test. The information literacy self-efficacy survey and the 25-item version of the information literacy knowledge test have shown preliminary evidence of adequate reliability and validity to justify continuing study with these instruments.

  2. Reliability and validity of clinical tests to assess the anatomical integrity of the cervical spine in adults with neck pain and its associated disorders: Part 1-A systematic review from the Cervical Assessment and Diagnosis Research Evaluation (CADRE) Collaboration.

    PubMed

    Lemeunier, Nadège; da Silva-Oolup, S; Chow, N; Southerst, D; Carroll, L; Wong, J J; Shearer, H; Mastragostino, P; Cox, J; Côté, E; Murnaghan, K; Sutton, D; Côté, P

    2017-09-01

    To determine the reliability and validity of clinical tests to assess the anatomical integrity of the cervical spine in adults with neck pain and its associated disorders. We updated the systematic review of the 2000-2010 Bone and Joint Decade Task Force on Neck Pain and its Associated Disorders. We also searched the literature to identify studies on the reliability and validity of Doppler velocimetry for the evaluation of cervical arteries. Two independent reviewers screened and critically appraised studies. We conducted a best evidence synthesis of low risk of bias studies and ranked the phases of investigations using the classification proposed by Sackett and Haynes. We screened 9022 articles and critically appraised 8 studies; all 8 studies had low risk of bias (three reliability and five validity Phase II-III studies). Preliminary evidence suggests that the extension-rotation test may be reliable and has adequate validity to rule out pain arising from facet joints. The evidence suggests variable reliability and preliminary validity for the evaluation of cervical radiculopathy including neurological examination (manual motor testing, dermatomal sensory testing, deep tendon reflexes, and pathological reflex testing), Spurling's and the upper limb neurodynamic tests. No evidence was found for doppler velocimetry. Little evidence exists to support the use of clinical tests to evaluate the anatomical integrity of the cervical spine in adults with neck pain and its associated disorders. We found preliminary evidence to support the use of the extension-rotation test, neurological examination, Spurling's and the upper limb neurodynamic tests.

  3. Intratester Reliability and Construct Validity of a Hip Abductor Eccentric Strength Test.

    PubMed

    Brindle, Richard A; Ebaugh, David; Milner, Clare E

    2018-06-06

    Side-lying hip abductor strength tests are commonly used to evaluate muscle strength. In a "break" test, the tester applies sufficient force to lower the limb to the table while the patient resists. The peak force is postulated to occur while the leg is lowering, thus representing the participant's eccentric muscle strength. However, it is unclear whether peak force occurs before or after the leg begins to lower. To determine intrarater reliability and construct validity of a hip abductor eccentric strength test. Intrarater reliability and construct validity study. Twenty healthy adults (26 [6] y; 1.66 [0.06] m; 62.2 [8.0] kg) made 2 visits to the laboratory at least 1 week apart. During the hip abductor eccentric strength test, a handheld dynamometer recorded peak force and time to peak force, and limb position was recorded via a motion capture system. Intrarater reliability was determined using intraclass correlation, SEM, and minimal detectable difference. Construct validity was assessed by determining if peak force occurred after the start of the lowering phase using a 1-sample t test. The hip abductor eccentric strength test had substantial intrarater reliability (intraclass correlation (3,3)  = .88; 95% confidence interval, .65-.95), SEM of 0.9 %BWh, and a minimal detectable difference of 2.5 %BWh. Construct validity was established as peak force occurred 2.1 (0.6) seconds (range: 0.7-3.7 s) after the start of the lowering phase of the test (P ≤ .001). The hip abductor eccentric strength test is a valid and reliable measure of eccentric muscle strength. This test may be used clinically to assess changes in eccentric muscle strength over time.

  4. Multiple objective optimization in reliability demonstration test

    DOE PAGES

    Lu, Lu; Anderson-Cook, Christine Michaela; Li, Mingyang

    2016-10-01

    Reliability demonstration tests are usually performed in product design or validation processes to demonstrate whether a product meets specified requirements on reliability. For binomial demonstration tests, the zero-failure test has been most commonly used due to its simplicity and use of minimum sample size to achieve an acceptable consumer’s risk level. However, this test can often result in unacceptably high risk for producers as well as a low probability of passing the test even when the product has good reliability. This paper explicitly explores the interrelationship between multiple objectives that are commonly of interest when planning a demonstration test andmore » proposes structured decision-making procedures using a Pareto front approach for selecting an optimal test plan based on simultaneously balancing multiple criteria. Different strategies are suggested for scenarios with different user priorities and graphical tools are developed to help quantify the trade-offs between choices and to facilitate informed decision making. As a result, potential impacts of some subjective user inputs on the final decision are studied to offer insights and useful guidance for general applications.« less

  5. Social anxiety questionnaire (SAQ): Development and preliminary validation.

    PubMed

    Łakuta, Patryk

    2018-05-30

    The Social Anxiety Questionnaire (SAQ) was designed to assess five dimensions of social anxiety as posited by the Clark and Wells' (1995; Clark, 2001) cognitive model. The development of the SAQ involved generation of an item pool, followed by a verification of content validity and the theorized factor structure (Study 1). The final version of the SAQ was then assessed for reliability, temporal stability (test re-test reliability), and construct, criterion-related, and contrasted-group validity (Study 2, 3, and 4). Following a systematic process, the results provide support for the SAQ as reliable, and both theoretically and empirically valid measure. A five-factor structure of the SAQ verified and replicated through confirmatory factor analyses reflect five dimensions of social anxiety: negative self-processing; self-focused attention and self-monitoring; safety behaviours; somatic and cognitive symptoms; and anticipatory and post-event rumination. Results suggest that the SAQ possesses good psychometric properties, while recognizing that additional validation is a required future research direction. It is important to replicate these findings in diverse populations, including a large clinical sample. The SAQ is a promising measure that supports social anxiety as a multidimensional construct, and the foundational role of self-focused cognitive processes in generation and maintenance of social anxiety symptoms. The findings make a significant contribution to the literature, moreover, the SAQ is a first instrument that offers to assess all, proposed by the Clark-Wells model, specific cognitive-affective, physiological, attitudinal, and attention processes related to social anxiety. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Development of the athlete sleep behavior questionnaire: A tool for identifying maladaptive sleep practices in elite athletes

    PubMed Central

    Driller, Matthew W; Mah, Cheri D; Halson, Shona L

    2018-01-01

    Introduction Existing sleep questionnaires to assess sleep behaviors may not be sensitive in determining the unique sleep challenges faced by elite athletes. The purpose of the current study was to develop and validate the Athlete Sleep Behavior Questionnaire (ASBQ) to be used as a practical tool for support staff working with elite athletes. Methods 564 participants (242 athletes, 322 non-athletes) completed the 18-item ASBQ and three previously validated questionnaires; the Sleep Hygiene Index (SHI), the Epworth Sleepiness Scale (ESS) and the Pittsburgh Sleep Quality Index (PSQI). A cohort of the studied population performed the ASBQ twice in one week to assess test-retest reliability, and also performed sleep monitoring via wrist-actigraphy. Results Comparison of the ASBQ with existing sleep questionnaires resulted in moderate to large correlations (r=0.32 - 0.69). There was a significant difference between athletes and non-athletes for the ASBQ global score (44±6 vs. 41±6, respectively, p<0.01) and for the PSQI, but not for the SHI or the ESS. The reliability of the ASBQ was acceptable (ICC=0.87) when re-tested within 7 days. There was a moderate relationship between ASBQ and total sleep time (r=-0.42). Conclusion The ASBQ is a valid and reliable tool that can differentiate the sleep practices between athletes and non-athletes, and offers a practical instrument for practitioners and/or researchers wanting to evaluate the sleep behaviors of elite athletes. The ASBQ may provide information on areas where improvements to individual athletes’ sleep habits could be made. PMID:29796200

  7. Reliability and information content of tests with cardioleader in cyclic types of sports

    NASA Technical Reports Server (NTRS)

    Utkin, V. L.

    1980-01-01

    Tests with cardioleader to control the physical, technical and tactical preparedness of athletes in cyclic types of sports are discussed. Ways of increasing the reliability and information content of the tests were studied.

  8. The usefulness and reliability of fitness testing protocols for ice hockey players: a literature review.

    PubMed

    Nightingale, Steven C; Miller, Stuart; Turner, Anthony

    2013-06-01

    Ice hockey, like most sports, uses fitness testing to assess athletes. This study reviews the current commonly used fitness testing protocols for ice hockey players, discussing their predictive values and reliability. It also discusses a range of less commonly used measures and limitations in current testing protocols. The article concludes with a proposed testing program suitable for ice hockey players.

  9. Crystalline-silicon reliability lessons for thin-film modules

    NASA Technical Reports Server (NTRS)

    Ross, Ronald G., Jr.

    1985-01-01

    Key reliability and engineering lessons learned from the 10-year history of the Jet Propulsion Laboratory's Flat-Plate Solar Array Project are presented and analyzed. Particular emphasis is placed on lessons applicable to the evolving new thin-film cell and module technologies and the organizations involved with these technologies. The user-specific demand for reliability is a strong function of the application, its location, and its expected duration. Lessons relative to effective means of specifying reliability are described, and commonly used test requirements are assessed from the standpoint of which are the most troublesome to pass, and which correlate best with field experience. Module design lessons are also summarized, including the significance of the most frequently encountered failure mechanisms and the role of encapsulant and cell reliability in determining module reliability. Lessons pertaining to research, design, and test approaches include the historical role and usefulness of qualification tests and field tests.

  10. Measuring deception: test-retest reliability of physicians' self-reported manipulation of reimbursement rules for patients.

    PubMed

    VanGeest, Jonathan B; Wynia, Matthew K; Cummins, Deborah S; Wilson, Ira B

    2002-06-01

    This study examined the test-retest reliability of physicians' self-reported manipulation of reimbursement rules for patients. The test-retest reliability of self-report of three specific tactics were examined: (1) exaggerating the severity of patients' conditions, (2) changing a patient's official (billing) diagnosis, and (3) reporting signs or symptoms that patients did not have. The reliability of a scaled summary measure of physicians' manipulation of reimbursement rules was also assessed. Overall, the authors found high levels of test-retest agreement across all three items and the summary measure. These findings suggest that self-report can be used to produce reliable data on this controversial issue. Specifically, the three items reported here can be used to produce a reliable summary measure of physicians' manipulation of reimbursement rules to help patients obtain care that physicians perceive as necessary.

  11. Self-esteem among nursing assistants: reliability and validity of the Rosenberg Self-Esteem Scale.

    PubMed

    McMullen, Tara; Resnick, Barbara

    2013-01-01

    To establish the reliability and validity of the Rosenberg Self-Esteem Scale (RSES) when used with nursing assistants (NAs). Testing the RSES used baseline data from a randomized controlled trial testing the Res-Care Intervention. Female NAs were recruited from nursing homes (n = 508). Validity testing for the positive and negative subscales of the RSES was based on confirmatory factor analysis (CFA) using structural equation modeling and Rasch analysis. Estimates of reliability were based on Rasch analysis and the person separation index. Evidence supports the reliability and validity of the RSES in NAs although we recommend minor revisions to the measure for subsequent use. Establishing reliable and valid measures of self-esteem in NAs will facilitate testing of interventions to strengthen workplace self-esteem, job satisfaction, and retention.

  12. EMC Test Report: StangSat - CubeSat Program

    NASA Technical Reports Server (NTRS)

    Carmody, Lynne M.; Aragona, Peter S.

    2013-01-01

    This report documents the Electromagnetic Interference E M I testing performed on the StangSat; the unit under test (UUT). Testing was per the requirements of MIL STD-461F. The UUT was characterized and passed the radiated emissions (RE102 limit for Spacecraft) testing.

  13. Heat Flux and Wall Temperature Estimates for the NASA Langley HIFiRE Direct Connect Rig

    NASA Technical Reports Server (NTRS)

    Cuda, Vincent, Jr.; Hass, Neal E.

    2010-01-01

    An objective of the Hypersonic International Flight Research Experimentation (HIFiRE) Program Flight 2 is to provide validation data for high enthalpy scramjet prediction tools through a single flight test and accompanying ground tests of the HIFiRE Direct Connect Rig (HDCR) tested in the NASA LaRC Arc Heated Scramjet Test Facility (AHSTF). The HDCR is a full-scale, copper heat sink structure designed to simulate the isolator entrance conditions and isolator, pilot, and combustor section of the HIFiRE flight test experiment flowpath and is fully instrumented to assess combustion performance over a range of operating conditions simulating flight from Mach 5.5 to 8.5 and for various fueling schemes. As part of the instrumentation package, temperature and heat flux sensors were provided along the flowpath surface and also imbedded in the structure. The purpose of this paper is to demonstrate that the surface heat flux and wall temperature of the Zirconia coated copper wall can be obtained with a water-cooled heat flux gage and a sub-surface temperature measurement. An algorithm was developed which used these two measurements to reconstruct the surface conditions along the flowpath. Determinations of the surface conditions of the Zirconia coating were conducted for a variety of conditions.

  14. Solidification Based Grain Refinement in Steels

    DTIC Science & Technology

    2011-09-27

    project (Tasks 7-9). An industrial trial on an investment casting was done using rare earth silicide additions in a furnace prior to pouring (Task 7...an investment casting was done using rare earth silicide additions in a furnace prior to pounng (la.sk 7). Some of the test parts had a finer...poured at the end of a six casting batch. One test tree with no RE addition was poured. Before the second test tree was poured, sufficient RE silicide was

  15. Traditional vs. Sport-Specific Vertical Jump Tests: Reliability, Validity, and Relationship With the Legs Strength and Sprint Performance in Adult and Teen Soccer and Basketball Players.

    PubMed

    Rodríguez-Rosell, David; Mora-Custodio, Ricardo; Franco-Márquez, Felipe; Yáñez-García, Juan M; González-Badillo, Juan J

    2017-01-01

    Rodríguez-Rosell, D, Mora-Custodio, R, Franco-Márquez, F, Yáñez-García, JM, González-Badillo, JJ. Traditional vs. sport-specific vertical jump tests: reliability, validity, and relationship with the legs strength and sprint performance in adult and teen soccer and basketball players. J Strength Cond Res 31(1): 196-206, 2017-The vertical jump is considered an essential motor skill in many team sports. Many protocols have been used to assess vertical jump ability. However, controversy regarding test selection still exists based on the reliability and specificity of the tests. The main aim of this study was to analyze the reliability and validity of 2 standardized (countermovement jump [CMJ] and Abalakov jump [AJ]) and 2 sport-specific (run-up with 2 [2-LEGS] or 1 leg [1-LEG] take-off jump) vertical jump tests, and their usefulness as predictors of sprint and strength performance for soccer (n = 127) and basketball (n = 59) players in 3 different categories (Under-15, Under-18, and Adults). Three attempts for each of the 4 jump tests were recorded. Twenty-meter sprint time and estimated 1 repetition maximum in full squat were also evaluated. All jump tests showed high intraclass correlation coefficients (0.969-0.995) and low coefficients of variation (1.54-4.82%), although 1-LEG was the jump test with the lowest absolute and relative reliability. All selected jump tests were significantly correlated (r = 0.580-0.983). Factor analysis resulted in the extraction of one principal component, which explained 82.90-95.79% of the variance of all jump tests. The 1-LEG test showed the lowest associations with sprint and strength performance. The results of this study suggest that CMJ and AJ are the most reliable tests for the estimation of explosive force in soccer and basketball players in different age categories.

  16. EXPERT: An atmospheric re-entry test-bed

    NASA Astrophysics Data System (ADS)

    Massobrio, F.; Viotto, R.; Serpico, M.; Sansone, A.; Caporicci, M.; Muylaert, J.-M.

    2007-06-01

    In recognition of the importance of an independent European access to the International Space Station (ISS) and in preparation for the future needs of exploration missions, ESA is conducting parallel activities to generate flight data using atmospheric re-entry test-beds and to identify vehicle design solutions for human and cargo transportation vehicles serving the ISS and beyond. The EXPERT (European eXPErimental Re-entry Test-bed) vehicle represents the major on-going development in the first class of activities. Its results may also benefit in due time scientific missions to planets with an atmosphere and future reusable launcher programmes. The objective of EXPERT is to provide a test-bed for the validation of aerothermodynamics models, codes and ground test facilities in a representative flight environment, to improve the understanding of issues related to analysis, testing and extrapolation to flight. The vehicle will be launched on a sub-orbital trajectory using a Volna missile. The EXPERT concept is based on a symmetrical re-entry capsule whose shape is composed of simple geometrical elements. The suborbital trajectory will reach 120 km altitude and a re-entry velocity of 5 6km/s. The dimensions of the capsule are 1.6 m high and 1.3 m diameter; the overall mass is in the range of 250 350kg, depending upon the mission parameters and the payload/instrumentation complement. A consistent number of scientific experiments are foreseen on-board, from innovative air data system to shock wave/boundary layer interaction, from sharp hot structures characterisation to natural and induced regime transition. Currently the project is approaching completion of the phase B, with Alenia Spazio leading the industrial team and CIRA coordinating the scientific payload development under ESA contract.

  17. Test-retest reliability of neurophysiological tests of hand-arm vibration syndrome in vibration exposed workers and unexposed referents.

    PubMed

    Gerhardsson, Lars; Gillström, Lennart; Hagberg, Mats

    2014-01-01

    Exposure to hand-held vibrating tools may cause the hand-arm vibration syndrome (HAVS). The aim was to study the test-retest reliability of hand and muscle strength tests, and tests for the determination of thermal and vibration perception thresholds, which are used when investigating signs of neuropathy in vibration exposed workers. In this study, 47 vibration exposed workers who had been investigated at the department of Occupational and Environmental Medicine in Gothenburg were compared with a randomized sample of 18 unexposed subjects from the general population of the city of Gothenburg. All participants passed a structured interview, answered several questionnaires and had a physical examination including hand and finger muscle strength tests, determination of vibrotactile (VPT) and thermal perception thresholds (TPT). Two weeks later, 23 workers and referents, selected in a randomized manner, were called back for the same test-procedures for the evaluation of test-retest reliability. The test-retest reliability after a two week interval expressed as limits of agreement (LOA; Bland-Altman), intra-class correlation coefficients (ICC) and Pearson correlation coefficients was excellent for tests with the Baseline hand grip, Pinch-grip and 3-Chuck grip among the exposed workers and referents (N = 23: percentage of differences within LOA 91 - 100%; ICC-values ≥0.93; Pearson r ≥0.93). The test-retest reliability was also excellent (percentage of differences within LOA 96-100 %) for the determination of vibration perception thresholds in digits 2 and 5 bilaterally as well as for temperature perception thresholds in digits 2 and 5, bilaterally (percentage of differences within LOA 91 - 96%). For ICC and Pearson r the results for vibration perception thresholds were good for digit 2, left hand and for digit 5, bilaterally (ICC ≥ 0.84; r ≥0.85), and lower (ICC = 0.59; r = 0.59) for digit 2, right hand. For the latter two indices the test-retest reliability for the determination of temperature thresholds was lower and showed more varying results. The strong test-retest reliability for hand and muscle strength tests as well as for the determination of VPTs makes these procedures useful for diagnostic purposes and follow-up studies in vibration exposed workers.

  18. Reliability of Autism-Tics, AD/HD, and other Comorbidities (A-TAC) inventory in a test-retest design.

    PubMed

    Larson, Tomas; Kerekes, Nóra; Selinus, Eva Norén; Lichtenstein, Paul; Gumpert, Clara Hellner; Anckarsäter, Henrik; Nilsson, Thomas; Lundström, Sebastian

    2014-02-01

    The Autism-Tics, AD/HD, and other Comorbidities (A-TAC) inventory is used in epidemiological research to assess neurodevelopmental problems and coexisting conditions. Although the A-TAC has been applied in various populations, data on retest reliability are limited. The objective of the present study was to present additional reliability data. The A-TAC was administered by lay assessors and was completed on two occasions by parents of 400 individual twins, with an average interval of 70 days between test sessions. Intra- and inter-rater reliability were analysed with intraclass correlations and Cohen's kappa. A-TAC showed excellent test-retest intraclass correlations for both autism spectrum disorder and attention deficit hyperactivity disorder (each at .84). Most modules in the A-TAC had intra- and inter-rater reliability intraclass correlation coefficients of > or = .60. Cohen's kappa indi- cated acceptable reliability. The current study provides statistical evidence that the A-TAC yields good test-retest reliability in a population-based cohort of children.

  19. Long-term Mechanical Circulatory Support System reliability recommendation by the National Clinical Trial Initiative subcommittee.

    PubMed

    Lee, James

    2009-01-01

    The Long-Term Mechanical Circulatory Support (MCS) System Reliability Recommendation was published in the American Society for Artificial Internal Organs (ASAIO) Journal and the Annals of Thoracic Surgery in 1998. At that time, it was stated that the document would be periodically reviewed to assess its timeliness and appropriateness within 5 years. Given the wealth of clinical experience in MCS systems, a new recommendation has been drafted by consensus of a group of representatives from the medical community, academia, industry, and government. The new recommendation describes a reliability test methodology and provides detailed reliability recommendations. In addition, the new recommendation provides additional information and clinical data in appendices that are intended to assist the reliability test engineer in the development of a reliability test that is expected to give improved predictions of clinical reliability compared with past test methods. The appendices are available for download at the ASAIO journal web site at www.asaiojournal.com.

  20. Validity and reliability of the NAB Naming Test.

    PubMed

    Sachs, Bonnie C; Rush, Beth K; Pedraza, Otto

    2016-05-01

    Confrontation naming is commonly assessed in neuropsychological practice, but few standardized measures of naming exist and those that do are susceptible to the effects of education and culture. The Neuropsychological Assessment Battery (NAB) Naming Test is a 31-item measure used to assess confrontation naming. Despite adequate psychometric information provided by the test publisher, there has been limited independent validation of the test. In this study, we investigated the convergent and discriminant validity, internal consistency, and alternate forms reliability of the NAB Naming Test in a sample of adults (Form 1: n = 247, Form 2: n = 151) clinically referred for neuropsychological evaluation. Results indicate adequate-to-good internal consistency and alternate forms reliability. We also found strong convergent validity as demonstrated by relationships with other neurocognitive measures. We found preliminary evidence that the NAB Naming Test demonstrates a more pronounced ceiling effect than other commonly used measures of naming. To our knowledge, this represents the largest published independent validation study of the NAB Naming Test in a clinical sample. Our findings suggest that the NAB Naming Test demonstrates adequate validity and reliability and merits consideration in the test arsenal of clinical neuropsychologists.

  1. Improving the quality of discrete-choice experiments in health: how can we assess validity and reliability?

    PubMed

    Janssen, Ellen M; Marshall, Deborah A; Hauber, A Brett; Bridges, John F P

    2017-12-01

    The recent endorsement of discrete-choice experiments (DCEs) and other stated-preference methods by regulatory and health technology assessment (HTA) agencies has placed a greater focus on demonstrating the validity and reliability of preference results. Areas covered: We present a practical overview of tests of validity and reliability that have been applied in the health DCE literature and explore other study qualities of DCEs. From the published literature, we identify a variety of methods to assess the validity and reliability of DCEs. We conceptualize these methods to create a conceptual model with four domains: measurement validity, measurement reliability, choice validity, and choice reliability. Each domain consists of three categories that can be assessed using one to four procedures (for a total of 24 tests). We present how these tests have been applied in the literature and direct readers to applications of these tests in the health DCE literature. Based on a stakeholder engagement exercise, we consider the importance of study characteristics beyond traditional concepts of validity and reliability. Expert commentary: We discuss study design considerations to assess the validity and reliability of a DCE, consider limitations to the current application of tests, and discuss future work to consider the quality of DCEs in healthcare.

  2. Reliability of Health-Related Physical Fitness Tests among Colombian Children and Adolescents: The FUPRECOL Study

    PubMed Central

    Ramírez-Vélez, Robinson; Rodrigues-Bezerra, Diogo; Correa-Bautista, Jorge Enrique; Izquierdo, Mikel; Lobelo, Felipe

    2015-01-01

    Substantial evidence indicates that youth physical fitness levels are an important marker of lifestyle and cardio-metabolic health profiles and predict future risk of chronic diseases. The reliability physical fitness tests have not been explored in Latino-American youth population. This study’s aim was to examine the reliability of health-related physical fitness tests that were used in the Colombian health promotion “Fuprecol study”. Participants were 229 Colombian youth (boys n = 124 and girls n = 105) aged 9 to 17.9 years old. Five components of health-related physical fitness were measured: 1) morphological component: height, weight, body mass index (BMI), waist circumference, triceps skinfold, subscapular skinfold, and body fat (%) via impedance; 2) musculoskeletal component: handgrip and standing long jump test; 3) motor component: speed/agility test (4x10 m shuttle run); 4) flexibility component (hamstring and lumbar extensibility, sit-and-reach test); 5) cardiorespiratory component: 20-meter shuttle-run test (SRT) to estimate maximal oxygen consumption. The tests were performed two times, 1 week apart on the same day of the week, except for the SRT which was performed only once. Intra-observer technical errors of measurement (TEMs) and inter-rater (reliability) were assessed in the morphological component. Reliability for the Musculoskeletal, motor and cardiorespiratory fitness components was examined using Bland–Altman tests. For the morphological component, TEMs were small and reliability was greater than 95% of all cases. For the musculoskeletal, motor, flexibility and cardiorespiratory components, we found adequate reliability patterns in terms of systematic errors (bias) and random error (95% limits of agreement). When the fitness assessments were performed twice, the systematic error was nearly 0 for all tests, except for the sit and reach (mean difference: -1.03% [95% CI = -4.35% to -2.28%]. The results from this study indicate that the “Fuprecol study” health-related physical fitness battery, administered by physical education teachers, was reliable for measuring health-related components of fitness in children and adolescents aged 9–17.9 years old in a school setting in Colombia. PMID:26474474

  3. Reliability of Health-Related Physical Fitness Tests among Colombian Children and Adolescents: The FUPRECOL Study.

    PubMed

    Ramírez-Vélez, Robinson; Rodrigues-Bezerra, Diogo; Correa-Bautista, Jorge Enrique; Izquierdo, Mikel; Lobelo, Felipe

    2015-01-01

    Substantial evidence indicates that youth physical fitness levels are an important marker of lifestyle and cardio-metabolic health profiles and predict future risk of chronic diseases. The reliability physical fitness tests have not been explored in Latino-American youth population. This study's aim was to examine the reliability of health-related physical fitness tests that were used in the Colombian health promotion "Fuprecol study". Participants were 229 Colombian youth (boys n = 124 and girls n = 105) aged 9 to 17.9 years old. Five components of health-related physical fitness were measured: 1) morphological component: height, weight, body mass index (BMI), waist circumference, triceps skinfold, subscapular skinfold, and body fat (%) via impedance; 2) musculoskeletal component: handgrip and standing long jump test; 3) motor component: speed/agility test (4x10 m shuttle run); 4) flexibility component (hamstring and lumbar extensibility, sit-and-reach test); 5) cardiorespiratory component: 20-meter shuttle-run test (SRT) to estimate maximal oxygen consumption. The tests were performed two times, 1 week apart on the same day of the week, except for the SRT which was performed only once. Intra-observer technical errors of measurement (TEMs) and inter-rater (reliability) were assessed in the morphological component. Reliability for the Musculoskeletal, motor and cardiorespiratory fitness components was examined using Bland-Altman tests. For the morphological component, TEMs were small and reliability was greater than 95% of all cases. For the musculoskeletal, motor, flexibility and cardiorespiratory components, we found adequate reliability patterns in terms of systematic errors (bias) and random error (95% limits of agreement). When the fitness assessments were performed twice, the systematic error was nearly 0 for all tests, except for the sit and reach (mean difference: -1.03% [95% CI = -4.35% to -2.28%]. The results from this study indicate that the "Fuprecol study" health-related physical fitness battery, administered by physical education teachers, was reliable for measuring health-related components of fitness in children and adolescents aged 9-17.9 years old in a school setting in Colombia.

  4. The development and psychometric testing of a Disaster Response Self-Efficacy Scale among undergraduate nursing students.

    PubMed

    Li, Hong-Yan; Bi, Rui-Xue; Zhong, Qing-Ling

    2017-12-01

    Disaster nurse education has received increasing importance in China. Knowing the abilities of disaster response in undergraduate nursing students is beneficial to promote teaching and learning. However, there are few valid and reliable tools that measure the abilities of disaster response in undergraduate nursing students. To develop a self-report scale of self-efficacy in disaster response for Chinese undergraduate nursing students and test its psychometric properties. Nursing students (N=318) from two medical colleges were chosen by purposive sampling. The Disaster Response Self-Efficacy Scale (DRSES) was developed and psychometrically tested. Reliability and content validity were studied. Construct validity was tested by exploratory and confirmatory factor analysis. Reliability was tested by internal consistency and test-retest reliability. The DRSES consisted of 3 factors and 19 items with a 5-point rating. The content validity was 0.91, Cronbach's alpha coefficient was 0.912, and the intraclass correlation coefficient for test-retest reliability was 0.953. The construct validity was good (χ 2 /df=2.440, RMSEA=0.068, NFI=0.907, CFI=0.942, IFI=0.430, p<0.001). The newly developed DRSES has proven good reliability and validity. It could therefore be used as an assessment tool to evaluate self-efficacy in disaster response for Chinese undergraduate nursing students. Copyright © 2017. Published by Elsevier Ltd.

  5. Psychometric Properties of the Adolescent Health Concern Inventory: The Persian Version

    PubMed Central

    Baheiraei, Azam; Ahmadi, Fazlollah; Foroushani, Abbas Rahimi; Ghofranipour, Fazlollah; Weiler, Robert M

    2013-01-01

    Objective It is important to consider the health concerns of adolescents before developing and implementing public health promotion or health education curriculum programs aimed at ameliorating priority health problems experienced by adolescents. The aim of this study was to test the psychometric properties of the original Adolescent Health Concern Inventory (AHCI) for use with an Iranian population. Methods This was a methodological study in which 50 adolescents with age range of 14-18 years were selected using convenience sampling. The translation and cultural adaptation process of The AHCI followed recognized and established guidelines. The face and content validity was established by analyzing feedback solicited from teenagers and professionals with expertise in health, sociology and psychology. Reliability was examined using test-retest and Cronbach's alpha for internal consistency reliability. Kappa and McNemar tests were used to examine test-retest reliability for each item. Results Minor cultural differences were identified and resolved during the translation process and determining the validity of the checklist. Results from Kappa and McNemar tests indicate a high degree of test-retest reliability. Internal consistency reliability as measured by Cronbach's alpha for the subscales were between 0.68 and 0.87 with total instrument reliability of 0.96 indicating considerable overall reliability. Conclusion The Persian version of the AHCI appears valid and reliable. Hence, it can be used for filling a gap in identifying the adolescents’ health concerns in the research and community settings and school health education programs in Iran to design appropriate interventions. PMID:23682249

  6. Validity and Reliability of the 8-Item Work Limitations Questionnaire.

    PubMed

    Walker, Timothy J; Tullar, Jessica M; Diamond, Pamela M; Kohl, Harold W; Amick, Benjamin C

    2017-12-01

    Purpose To evaluate factorial validity, scale reliability, test-retest reliability, convergent validity, and discriminant validity of the 8-item Work Limitations Questionnaire (WLQ) among employees from a public university system. Methods A secondary analysis using de-identified data from employees who completed an annual Health Assessment between the years 2009-2015 tested research aims. Confirmatory factor analysis (CFA) (n = 10,165) tested the latent structure of the 8-item WLQ. Scale reliability was determined using a CFA-based approach while test-retest reliability was determined using the intraclass correlation coefficient. Convergent/discriminant validity was tested by evaluating relations between the 8-item WLQ with health/performance variables for convergent validity (health-related work performance, number of chronic conditions, and general health) and demographic variables for discriminant validity (gender and institution type). Results A 1-factor model with three correlated residuals demonstrated excellent model fit (CFI = 0.99, TLI = 0.99, RMSEA = 0.03, and SRMR = 0.01). The scale reliability was acceptable (0.69, 95% CI 0.68-0.70) and the test-retest reliability was very good (ICC = 0.78). Low-to-moderate associations were observed between the 8-item WLQ and the health/performance variables while weak associations were observed between the demographic variables. Conclusions The 8-item WLQ demonstrated sufficient reliability and validity among employees from a public university system. Results suggest the 8-item WLQ is a usable alternative for studies when the more comprehensive 25-item WLQ is not available.

  7. Validity and Reliability Study of the Korean Tinetti Mobility Test for Parkinson's Disease.

    PubMed

    Park, Jinse; Koh, Seong-Beom; Kim, Hee Jin; Oh, Eungseok; Kim, Joong-Seok; Yun, Ji Young; Kwon, Do-Young; Kim, Younsoo; Kim, Ji Seon; Kwon, Kyum-Yil; Park, Jeong-Ho; Youn, Jinyoung; Jang, Wooyoung

    2018-01-01

    Postural instability and gait disturbance are the cardinal symptoms associated with falling among patients with Parkinson's disease (PD). The Tinetti mobility test (TMT) is a well-established measurement tool used to predict falls among elderly people. However, the TMT has not been established or widely used among PD patients in Korea. The purpose of this study was to evaluate the reliability and validity of the Korean version of the TMT for PD patients. Twenty-four patients diagnosed with PD were enrolled in this study. For the interrater reliability test, thirteen clinicians scored the TMT after watching a video clip. We also used the test-retest method to determine intrarater reliability. For concurrent validation, the unified Parkinson's disease rating scale, Hoehn and Yahr staging, Berg Balance Scale, Timed-Up and Go test, 10-m walk test, and gait analysis by three-dimensional motion capture were also used. We analyzed receiver operating characteristic curve to predict falling. The interrater reliability and intrarater reliability of the Korean Tinetti balance scale were 0.97 and 0.98, respectively. The interrater reliability and intra-rater reliability of the Korean Tinetti gait scale were 0.94 and 0.96, respectively. The Korean TMT scores were significantly correlated with the other clinical scales and three-dimensional motion capture. The cutoff values for predicting falling were 14 points (balance subscale) and 10 points (gait subscale). We found that the Korean version of the TMT showed excellent validity and reliability for gait and balance and had high sensitivity and specificity for predicting falls among patients with PD.

  8. [Reliability of static posturography in elderly persons].

    PubMed

    Bauer, C M; Gröger, I; Rupprecht, R; Tibesku, C O; Gassmann, K G

    2010-08-01

    Static posturography is used to quantify body sway. It is used to assess the balance of elderly persons who are prone to falls. There is still no general opinion concerning the reliability of force platform measurements. The aim of this study was to test the reliability of force platform parameters when measuring elderly persons. The reliability of 11 force platform parameters was tested measuring 30 elderly persons. The following parameters were calculated: mean speed of center of pressure displacement in mm/s, length of sway in mm, sway area in mm(2), amplitudes of center of pressure movement, the axis of oscillation in degrees and the person's angles of inclination in degrees. Three measurements were taken on the same day, with a resting period of 2 min. Four different test conditions were used: normal standing and narrow stand with eyes open and eyes closed, respectively. Reliability was determined by using intraclass correlation coefficients. Six parameters had excellent reliability with a correlation coefficient of >0.9: mean speed of center of pressure movement during narrow stand, area of sway during narrow stand, length of sway during normal and narrow stand, and the angle of inclination in the sagittal plane during normal stand and narrow stand. The condition "narrow stand eyes closed" proved to be the most reliable test position. Six parameters proved to have excellent reliability and are recommended to be used in further investigations. Narrow stand with eyes closed should be used as the test position. The tested protocol proved to be reliable. Whether these parameters can be used to predict falls in elderly persons remains to be investigated.

  9. Look--but also listen! ReQuest: A new dimension-oriented GERD symptom scale.

    PubMed

    Bardhan, Karna Dev

    2004-03-01

    The symptom spectrum of gastroesophageal reflux disease (GERD) is much wider than is commonly believed, and in about half the patients endoscopic examination is negative. The role of endoscopy to assess response to treatment is therefore much reduced in GERD. Assessment of symptoms is becoming increasingly important, so different outcome measures are required. The Reflux Questionnaire ReQuest was thus designed as a brief, effective and robust method of tracking and quantifying GERD symptoms during treatment. It comprises seven dimensions: general well-being, acid complaints, upper abdominal/stomach complaints, lower abdominal/digestive complaints, nausea, sleep disturbances and other complaints. In the short version of ReQuest the symptom burden of each dimension is measured by its frequency and intensity (except general well-being, for which only the intensity was determined). The long version also includes 67 symptom descriptions that constitute the dimensions (except general well-being). The rigorous validation process included clinical trial evaluation and statistical assessment of the findings. Important measures of the instrument, such as internal consistency, test/ retest reliability, construct validity and the responsiveness to changes during treatment, among others, all fulfilled or exceeded requirements, thereby demonstrating the accuracy of the instrument. ReQuest meets the criteria set by regulatory authorities and serves as the primary outcome measure for symptom assessment in future clinical trials of current and new treatments. (c) 2004 Prous Science

  10. A comparison of four geophysical methods for determining the shear wave velocity of soils

    USGS Publications Warehouse

    Anderson, N.; Thitimakorn, T.; Ismail, A.; Hoffman, D.

    2007-01-01

    The Missouri Department of Transportation (MoDOT) routinely acquires seismic cone penetrometer (SCPT) shear wave velocity control as part of the routine investigation of soils within the Mississippi Embayment. In an effort to ensure their geotechnical investigations are as effective and efficient as possible, the SCPT tool and several available alternatives (crosshole [CH]; multichannel analysis of surface waves [MASW]; and refraction microtremor [ReMi]) were evaluated and compared on the basis of field data acquired at two test sites in southeast Missouri. These four methods were ranked in terms of accuracy, functionality, cost, other considerations, and overall utility. It is concluded that MASW data are generally more reliable than SCPT data, comparable to quality ReMi data, and only slightly less accurate than CH data. However, the other advantages of MASW generally make it a superior choice over the CH, SCPT, and ReMi methods for general soil classification purposes to depths of 30 m. MASW data are less expensive than CH data and SCPT data and can normally be acquired in areas inaccessible to drill and SCPT rigs. In contrast to the MASW tool, quality ReMi data can be acquired only in areas where there are interpretable levels of "passive" acoustic energy and only when the geophone array is aligned with the source(s) of such energy.

  11. Translation, reliability, and clinical utility of the Melbourne Assessment 2.

    PubMed

    Gerber, Corinna N; Plebani, Anael; Labruyère, Rob

    2017-10-12

    The aims were to (i) provide a German translation of the Melbourne Assessment 2 (MA2), a quantitative test to measure unilateral upper limb function in children with neurological disabilities and (ii) to evaluate its reliability and aspects of clinical utility. After its translation into German and approval of the back translation by the original authors, the MA2 was performed and videotaped twice with 30 children with neuromotor disorders. For each participant, two raters scored the video of the first test for inter-rater reliability. To determine test-retest reliability, one rater additionally scored the video of the second test while the other rater repeated the scoring of the first video to evaluate intra-rater reliability. Time needed for rater training, test administration, and scoring was recorded. The four subscale scores showed excellent intra-, inter-rater, and test-retest reliability with intraclass correlation coefficients of 0.90-1.00 (95%-confidence intervals 0.78-1.00). Score items revealed substantial to almost perfect intra-rater reliability (weighted kappa k w  = 0.66-1.00) for the more affected side. Score item inter-rater and test-retest reliability of the same extremity were, with one exception, moderate to almost perfect (k w  = 0.42-0.97; k w  = 0.40-0.89). Furthermore, the MA2 was feasible and acceptable for patients and clinicians. The MA2 showed excellent subscale and moderate to almost perfect score item reliability. Implications for Rehabilitation There is a lack of high-quality studies about psychometric properties of upper limb measurement tools in the neuropediatric population. The Melbourne Assessment 2 is a promising tool for reliable measurement of unilateral upper limb movement quality in the neuropediatric population. The Melbourne Assessment 2 is acceptable and practicable to therapists and patients for routine use in clinical care.

  12. A comprehensive overview of urogenital, anorectal and oropharyngeal Neisseria gonorrhoeae testing and diagnoses among different STI care providers: a cross-sectional study.

    PubMed

    den Heijer, Casper D J; Hoebe, Christian J P A; van Liere, Geneviève A F S; van Bergen, Jan E A M; Cals, Jochen W L; Stals, Frans S; Dukers-Muijrers, Nicole H T M

    2017-04-20

    Gonorrhoea, caused by Neisseria gonorrhoeae (NG), can cause reproductive morbidity, is increasingly becoming resistant to antibiotics and is frequently asymptomatic, which shows the essential role of NG test practice. In this study we wanted to compare NG diagnostic testing procedures between different STI care providers serving a defined geographic Dutch region (280,000 inhabitants). Data on laboratory testing and diagnosis of urogenital and extragenital (i.e. anorectal and oropharyngeal) NG were retrieved from general practitioners (GPs), an STI clinic, and gynaecologists (2006-2010). Per provider, we assessed their contribution regarding the total number of tests performed and type of populations tested, the proportion of NG positives re-tested (3-12 months after treatment) and test-of-cure (TOC, within 3 months post treatment). Overall, 17,702 NG tests (48.7% STI clinic, 38.2% GPs, 13.1% gynaecologists) were performed during 15,458 patient visits. From this total number of tests, 2257 (12.7%) were extragenital, of which 99.4% were performed by the STI clinic. Men were mostly tested at the STI clinic (71%) and women by their GP (43%). NG positivity per visit was 1.6%; GP 1.9% (n = 111), STI clinic 1.7% (n = 131) and gynaecology 0.2% (n = 5). NG positivity was associated with Chlamydia trachomatis positivity (OR: 2.06, 95% confidence interval: 1.46-2.92). Per anatomical location, the proportion of NG positives re-tested were: urogenital 20.3% (n = 36), anorectal 43.6% (n = 17) and oropharyngeal 57.1% (n = 20). NG positivity among re-tests was 16.9%. Proportions of NG positives with TOC by anatomical location were: urogenital 10.2% (n = 18), anorectal 17.9% (n = 7) and oropharyngeal 17.1% (n = 6). To achieve best practice in relation to NG testing, we recommend that: 1) GPs test at extragenital sites, especially men who have sex with men (MSM), 2) all care providers consider re-testing 3 to 12 months after NG diagnosis and 3) TOC is performed following oropharyngeal NG diagnosis in settings which provide services to higher-risk men and women (such as STI clinics).

  13. Reliability of perceived neighbourhood conditions and the effects of measurement error on self-rated health across urban and rural neighbourhoods.

    PubMed

    Pruitt, Sandi L; Jeffe, Donna B; Yan, Yan; Schootman, Mario

    2012-04-01

    Limited psychometric research has examined the reliability of self-reported measures of neighbourhood conditions, the effect of measurement error on associations between neighbourhood conditions and health, and potential differences in the reliabilities between neighbourhood strata (urban vs rural and low vs high poverty). We assessed overall and stratified reliability of self-reported perceived neighbourhood conditions using five scales (social and physical disorder, social control, social cohesion, fear) and four single items (multidimensional neighbouring). We also assessed measurement error-corrected associations of these conditions with self-rated health. Using random-digit dialling, 367 women without breast cancer (matched controls from a larger study) were interviewed twice, 2-3 weeks apart. Test-retest (intraclass correlation coefficients (ICC)/weighted κ) and internal consistency reliability (Cronbach's α) were assessed. Differences in reliability across neighbourhood strata were tested using bootstrap methods. Regression calibration corrected estimates for measurement error. All measures demonstrated satisfactory internal consistency (α ≥ 0.70) and either moderate (ICC/κ=0.41-0.60) or substantial (ICC/κ=0.61-0.80) test-retest reliability in the full sample. Internal consistency did not differ by neighbourhood strata. Test-retest reliability was significantly lower among rural (vs urban) residents for two scales (social control, physical disorder) and two multidimensional neighbouring items; test-retest reliability was higher for physical disorder and lower for one multidimensional neighbouring item among the high (vs low) poverty strata. After measurement error correction, the magnitude of associations between neighbourhood conditions and self-rated health were larger, particularly in the rural population. Research is needed to develop and test reliable measures of perceived neighbourhood conditions relevant to the health of rural populations.

  14. Psychometric Properties of Performance-based Measurements of Functional Capacity: Test-Retest Reliability, Practice Effects, and Potential Sensitivity to Change

    PubMed Central

    Leifker, Feea R.; Patterson, Thomas L.; Bowie, Christopher R.; Mausbach, Brent T.; Harvey, Philip D.

    2010-01-01

    Performance-based measures of the ability to perform social and everyday living skills are being more widely used to assess functional capacity in people with serious mental illnesses such as schizophrenia and bipolar disorder. Since they are also being used as outcome measures in pharmacological and cognitive remediation studies aimed at cognitive impairments in schizophrenia, understanding their measurement properties and potential sensitivity to change is important. In this study, the test-retest reliability, practice effects, and reliable change indices of two different performance-based functional capacity measures, the UCSD Performance-based skills assessment (UPSA) and Social skills performance assessment (SSPA) were examined over several different retest intervals in two different samples of people with schizophrenia (n’s=238 and 116) and a healthy comparison sample (n=109). These psychometric properties were compared to those of a neuropsychological assessment battery. Test-retest reliabilities of the long form of the UPSA ranged from r=.63 to r=.80 over follow-up periods up to 36 months in people with schizophrenia, while brief UPSA reliabilities ranged from r=.66 to r=.81. Test-retest reliability of the NP performance scores ranged from r=.77 to r=.79. Test-retest reliabilities of the UPSA were lower in healthy controls, while NP performance was slightly more reliable. SSPA test-retest reliability was lower. Practice effect sizes ranged from .05 to .16 for the UPSA and .07 to .19 for the NP assessment in patients, with HC having more practice effects. Reliable change intervals were consistent across NP and both FC measures, indicating equal potential for detection of change. These performance-based measures of functional capacity appear to have similar potential to be sensitive to change compared to NP performance in people with schizophrenia. PMID:20399613

  15. The use of test structures for reliability prediction and process control of integrated circuits and photovoltaics

    NASA Astrophysics Data System (ADS)

    Trachtenberg, I.

    How a reliability model might be developed with new data from accelerated stress testing, failure mechanisms, process control monitoring, and test structure evaluations is illustrated. The effects of the acceleration of temperature on operating life is discussed. Test structures that will further accelerate the failure rate are discussed. Corrosion testing is addressed. The uncoated structure is encapsulated in a variety of mold compounds and subjected to pressure-cooker testing.

  16. Test-Retest Reliability of the 10-Metre Fast Walk Test and 6-Minute Walk Test in Ambulatory School-Aged Children with Cerebral Palsy

    ERIC Educational Resources Information Center

    Thompson, Patricia; Beath, Tricia; Bell, Jacqueline; Jacobson, Gabrielle; Phair, Tegan; Salbach, Nancy M.; Wright, F. Virginia

    2008-01-01

    Short-term test-retest reliability of the 10-metre fast walk test (10mFWT) and 6-minute walk test (6MWT) was evaluated in 31 ambulatory children with cerebral palsy (CP), with subgroup analyses in Gross Motor Function Classification System (GMFCS) Levels I (n=9), II (n=8), and III (n=14). Sixteen females and 15 males participated, mean age 9 years…

  17. Determining the Appropriateness of the "What If" Situations Test (WIST) with Turkish Pre-Schoolers.

    PubMed

    Citak Tunc, Gulseren; Gorak, Gulay; Ozyazicioglu, Nurcan; Ak, Bedriye; Isil, Ozlem; Vural, Pinar

    2018-04-01

    Measurement instruments are needed to assess the child's sexual abuse prevention program. The purpose of the study was to determine the reliability and validity of the WIST (What If Situations Test) for Turkish culture. Participants were children of the 3-6 age group attending pre-school education institutions and the sample size was identified by means of a power analysis. Seventy children were identified as the sample with 0.85 power and 0.05 type I error according to the power analysis. Language validity, content validity, internal validity coefficient (Cronbach alpha coefficient), and test-retest analyses were conducted in terms of validity and reliability in the scope of efforts for adaptation to Turkish culture. Firstly, Kendall W = 0.83 was the score for the expert opinions concerning the content validity of the language validity scale. It was found that the Cronbach alpha coefficients were between 0.68 and 0.90 for the scale sub-dimensions of appropriate and inappropriate recognition, saying, doing, telling, and reporting. The test-retest reliability of the scale was found to be r = 0.89 and the test-retest reliabilities for the sub-dimensions (appropriate recognition, inappropriate recognition, say skills, do skills, tell skills, and reporting skills) were between r = 0.48 and r = 0.92. The test-retest reliability for the Personal Safety Questionnaire (PSQ), as having complimentary items to the WIST, was found to be r = 0.82. The reliability and validity analysis of the 'What If' Situations Test (WIST), used to evaluate pre-schoolers' skills regarding self-protection against sexual abuse, showed that the Test's adaptation to Turkish culture was reliable and valid.

  18. The Pareidolia Test: A Simple Neuropsychological Test Measuring Visual Hallucination-Like Illusions.

    PubMed

    Mamiya, Yasuyuki; Nishio, Yoshiyuki; Watanabe, Hiroyuki; Yokoi, Kayoko; Uchiyama, Makoto; Baba, Toru; Iizuka, Osamu; Kanno, Shigenori; Kamimura, Naoto; Kazui, Hiroaki; Hashimoto, Mamoru; Ikeda, Manabu; Takeshita, Chieko; Shimomura, Tatsuo; Mori, Etsuro

    2016-01-01

    Visual hallucinations are a core clinical feature of dementia with Lewy bodies (DLB), and this symptom is important in the differential diagnosis and prediction of treatment response. The pareidolia test is a tool that evokes visual hallucination-like illusions, and these illusions may be a surrogate marker of visual hallucinations in DLB. We created a simplified version of the pareidolia test and examined its validity and reliability to establish the clinical utility of this test. The pareidolia test was administered to 52 patients with DLB, 52 patients with Alzheimer's disease (AD) and 20 healthy controls (HCs). We assessed the test-retest/inter-rater reliability using the intra-class correlation coefficient (ICC) and the concurrent validity using the Neuropsychiatric Inventory (NPI) hallucinations score as a reference. A receiver operating characteristic (ROC) analysis was used to evaluate the sensitivity and specificity of the pareidolia test to differentiate DLB from AD and HCs. The pareidolia test required approximately 15 minutes to administer, exhibited good test-retest/inter-rater reliability (ICC of 0.82), and moderately correlated with the NPI hallucinations score (rs = 0.42). Using an optimal cut-off score set according to the ROC analysis, and the pareidolia test differentiated DLB from AD with a sensitivity of 81% and a specificity of 92%. Our study suggests that the simplified version of the pareidolia test is a valid and reliable surrogate marker of visual hallucinations in DLB.

  19. Improving the Test-Retest Reliability of Resting State fMRI by Removing the Impact of Sleep.

    PubMed

    Wang, Jiahui; Han, Junwei; Nguyen, Vinh T; Guo, Lei; Guo, Christine C

    2017-01-01

    Resting state functional magnetic resonance imaging (rs-fMRI) provides a powerful tool to examine large-scale neural networks in the human brain and their disturbances in neuropsychiatric disorders. Thanks to its low demand and high tolerance, resting state paradigms can be easily acquired from clinical population. However, due to the unconstrained nature, resting state paradigm is associated with excessive head movement and proneness to sleep. Consequently, the test-retest reliability of rs-fMRI measures is moderate at best, falling short of widespread use in the clinic. Here, we characterized the effect of sleep on the test-retest reliability of rs-fMRI. Using measures of heart rate variability (HRV) derived from simultaneous electrocardiogram (ECG) recording, we identified portions of fMRI data when subjects were more alert or sleepy, and examined their effects on the test-retest reliability of functional connectivity measures. When volumes of sleep were excluded, the reliability of rs-fMRI is significantly improved, and the improvement appears to be general across brain networks. The amount of improvement is robust with the removal of as much as 60% volumes of sleepiness. Therefore, test-retest reliability of rs-fMRI is affected by sleep and could be improved by excluding volumes of sleepiness as indexed by HRV. Our results suggest a novel and practical method to improve test-retest reliability of rs-fMRI measures.

  20. 77 FR 9628 - Taking and Importing Marine Mammals: Taking Marine Mammals Incidental to Navy's Mission...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-17

    ..., and post-test monitoring for both sonar events. No stranded or injured marine mammals or sea turtles.... The monitoring included two re-test flights; two flights during the test; and one post-test flight... two pre-test flights; one flight during the test; and one post-test flight. Focal follow behavioral...

Top